Killeen, Gerry F; Smith, Tom A; Ferguson, Heather M; Mshinda, Hassan; Abdulla, Salim; Lengeler, Christian; Kachur, Steven P
2007-01-01
Background Malaria prevention in Africa merits particular attention as the world strives toward a better life for the poorest. Insecticide-treated nets (ITNs) represent a practical means to prevent malaria in Africa, so scaling up coverage to at least 80% of young children and pregnant women by 2010 is integral to the Millennium Development Goals (MDG). Targeting individual protection to vulnerable groups is an accepted priority, but community-level impacts of broader population coverage are largely ignored even though they may be just as important. We therefore estimated coverage thresholds for entire populations at which individual- and community-level protection are equivalent, representing rational targets for ITN coverage beyond vulnerable groups. Methods and Findings Using field-parameterized malaria transmission models, we show that high (80% use) but exclusively targeted coverage of young children and pregnant women (representing <20% of the population) will deliver limited protection and equity for these vulnerable groups. In contrast, relatively modest coverage (35%–65% use, with this threshold depending on ecological scenario and net quality) of all adults and children, rather than just vulnerable groups, can achieve equitable community-wide benefits equivalent to or greater than personal protection. Conclusions Coverage of entire populations will be required to accomplish large reductions of the malaria burden in Africa. While coverage of vulnerable groups should still be prioritized, the equitable and communal benefits of wide-scale ITN use by older children and adults should be explicitly promoted and evaluated by national malaria control programmes. ITN use by the majority of entire populations could protect all children in such communities, even those not actually covered by achieving existing personal protection targets of the MDG, Roll Back Malaria Partnership, or the US President's Malaria Initiative. PMID:17608562
42 CFR 440.335 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 4 2013-10-01 2013-10-01 false Benchmark-equivalent health benefits coverage. 440... and Benchmark-Equivalent Coverage § 440.335 Benchmark-equivalent health benefits coverage. (a) Aggregate actuarial value. Benchmark-equivalent coverage is health benefits coverage that has an aggregate...
42 CFR 440.335 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Benchmark-equivalent health benefits coverage. 440... and Benchmark-Equivalent Coverage § 440.335 Benchmark-equivalent health benefits coverage. (a) Aggregate actuarial value. Benchmark-equivalent coverage is health benefits coverage that has an aggregate...
42 CFR 440.330 - Benchmark health benefits coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Benchmark-Equivalent Coverage § 440.330 Benchmark health benefits coverage. Benchmark coverage is health...) Federal Employees Health Benefit Plan Equivalent Coverage (FEHBP—Equivalent Health Insurance Coverage). A benefit plan equivalent to the standard Blue Cross/Blue Shield preferred provider option service benefit...
42 CFR 440.330 - Benchmark health benefits coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Benchmark-Equivalent Coverage § 440.330 Benchmark health benefits coverage. Benchmark coverage is health...) Federal Employees Health Benefit Plan Equivalent Coverage (FEHBP—Equivalent Health Insurance Coverage). A benefit plan equivalent to the standard Blue Cross/Blue Shield preferred provider option service benefit...
42 CFR 440.330 - Benchmark health benefits coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Benchmark-Equivalent Coverage § 440.330 Benchmark health benefits coverage. Benchmark coverage is health...) Federal Employees Health Benefit Plan Equivalent Coverage (FEHBP—Equivalent Health Insurance Coverage). A benefit plan equivalent to the standard Blue Cross/Blue Shield preferred provider option service benefit...
42 CFR 440.330 - Benchmark health benefits coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Benchmark-Equivalent Coverage § 440.330 Benchmark health benefits coverage. Benchmark coverage is health...) Federal Employees Health Benefit Plan Equivalent Coverage (FEHBP—Equivalent Health Insurance Coverage). A benefit plan equivalent to the standard Blue Cross/Blue Shield preferred provider option service benefit...
42 CFR 457.430 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Benchmark-equivalent health benefits coverage. 457... STATES State Plan Requirements: Coverage and Benefits § 457.430 Benchmark-equivalent health benefits coverage. (a) Aggregate actuarial value. Benchmark-equivalent coverage is health benefits coverage that has...
42 CFR 457.430 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 4 2013-10-01 2013-10-01 false Benchmark-equivalent health benefits coverage. 457... STATES State Plan Requirements: Coverage and Benefits § 457.430 Benchmark-equivalent health benefits coverage. (a) Aggregate actuarial value. Benchmark-equivalent coverage is health benefits coverage that has...
42 CFR 457.430 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Benchmark-equivalent health benefits coverage. 457... STATES State Plan Requirements: Coverage and Benefits § 457.430 Benchmark-equivalent health benefits coverage. (a) Aggregate actuarial value. Benchmark-equivalent coverage is health benefits coverage that has...
42 CFR 440.335 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Benchmark-equivalent health benefits coverage. 440.335 Section 440.335 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND... and Benchmark-Equivalent Coverage § 440.335 Benchmark-equivalent health benefits coverage. (a...
42 CFR 440.335 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Benchmark-equivalent health benefits coverage. 440.335 Section 440.335 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND... and Benchmark-Equivalent Coverage § 440.335 Benchmark-equivalent health benefits coverage. (a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galavis, P; Barbee, D; Jozsef, G
2016-06-15
Purpose: Prone accelerated partial breast irradiation (APBI) results in dose reduction to the heart and lung. Flattening filter free beams (FFF) reduce out of field dose due to the reduced scatter from the removal of the flattening filter and reduce the buildup region. The aim of this work is to evaluate the dosimetric advantages of FFF beams to prone APBI target coverage and reduction in dose to organs at risk. Methods: Fifteen clinical prone APBI cases using flattened photon beams were retrospectively re-planned in Eclipse-TPS using FFF beams. FFF plans were designed to provide equivalent target coverage with similar hotspotsmore » using the same field arrangements, resulting in comparable target DVHs. Both plans were transferred to a prone breast phantom and delivered on Varian-Edge-Linac. GafChromic-film was placed in the coronal plane of the phantom, partially overlapping the treatment field and extending into OARs to compare dose profiles from both plans. Results: FFF plans were comparable to the clinical plans with maximum doses of (108.3±2.3)% and (109.2±2.4)% and mean doses of (104.5±1.0)% and (104.6±1.2)%, respectively. Similar mean dose doses to the heart and contralateral lungs were observed from both plans, whereas the mean dose to the contra-lateral breast was (2.79±1.18) cGy and (2.86±1.40) cGy for FFF and clinical plans respectively. However for both plans the error between calculated and measured doses at 4 cm from the field edge was 10%. Conclusion: The results showed that FFF beams in prone APBI provide dosimetrically equivalent target coverage and improved coverage in superficial target due to softer energy spectra. Film analysis showed that the TPS underestimates dose outside field edges for both cases. The FFF measured plans showed less dose outside the beam that might reduce the probability of secondary cancers in the contralateral breast.« less
42 CFR 440.335 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Aggregate actuarial value. Benchmark-equivalent coverage is health benefits coverage that has an aggregate... planning services and supplies and other appropriate preventive services, as designated by the Secretary... State for purposes of comparison in establishing the aggregate actuarial value of the benchmark...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, Y; Shahnazi, K; Wang, W
Purpose: Ion beams have an unavoidable lateral spread due to nuclear interactions interacting with the air and monitoring systems. To minimize this spread, the distance between the nozzle and the patient should be kept as small as possible.The purpose of this work was to determine the impact of the target-to-nozzle distance reduction on the secondary neutron dose equivalent in proton and carbon ion radiotherapy. Methods: In this study, abdominal and head phantoms were scanned with our CT scanner. Cubical targets with side lengths of 3 cm to 10 cm and 1 cm to 5 cm were drawn in the abdominalmore » and head phantoms respectively. Two intensity-modulated plans were made for each phantom and ion. The first of these plans placed the target at the isocenter while the other shifted the phantom 30 cm towards the nozzle. The plans at both phantom locations were optimized to provide identical dose coverage to the PTVs.Secondary neutron dose equivalent at 50 cm lateral to the center of target. Results: The neutron dose equivalent was higher for the larger field size from 0.25µSv per Gy (RBE) to 72µSv per Gy (RBE). The neutron dose equivalent was smaller when the phantom was placed at the upstream target location versus at the isocenter location by 8.9% to 10.4% and 11.0% to 22.1% for proton plans of the abdominal and head phantoms respectively. Differences for carbon plans with different target-to-nozzle locations were less than 3% for both phantoms. Conclusion: A reduction of target-to-nozzle distance can lead to benefits for proton radiotherapy. In this study, a reduction of secondary neutron dose equivalent was found for proton plans with a smaller target-to-nozzle distance. A greater impact was found for a head phantom with a smaller field size; however, a reduction of the target-to-nozzle distance had little effect for carbon therapy.« less
Treuer, Harald; Hoevels, Moritz; Luyken, Klaus; Visser-Vandewalle, Veerle; Wirths, Jochen; Kocher, Martin; Ruge, Maximilian
2015-06-01
Stereotactic radiosurgery with an adapted linear accelerator (linac-SRS) is an established therapy option for brain metastases, benign brain tumors, and arteriovenous malformations. We intended to investigate whether the dosimetric quality of treatment plans achieved with a CyberKnife (CK) is at least equivalent to that for linac-SRS with circular or micromultileaf collimators (microMLC). A random sample of 16 patients with 23 target volumes, previously treated with linac-SRS, was replanned with CK. Planning constraints were identical dose prescription and clinical applicability. In all cases uniform optimization scripts and inverse planning objectives were used. Plans were compared with respect to coverage, minimal dose within target volume, conformity index, and volume of brain tissue irradiated with ≥ 10 Gy. Generating the CK plan was unproblematic with simple optimization scripts in all cases. With the CK plans, coverage, minimal target volume dosage, and conformity index were significantly better, while no significant improvement could be shown regarding the 10 Gy volume. Multiobjective comparison for the irradiated target volumes was superior in the CK plan in 20 out of 23 cases and equivalent in 3 out of 23 cases. Multiobjective comparison for the treated patients was superior in the CK plan in all 16 cases. The results clearly demonstrate the superiority of the irradiation plan for CK compared to classical linac-SRS with circular collimators and microMLC. In particular, the average minimal target volume dose per patient, increased by 1.9 Gy, and at the same time a 14% better conformation index seems to be an improvement with clinical relevance.
VizieR Online Data Catalog: XQ-100 targets equivalent widths (Perrotta+, 2016)
NASA Astrophysics Data System (ADS)
Perrotta, S.; D'Odorico, V.; Prochaska, J. X.; Cristiani, S.; Cupani, G.; Ellison, S.; Lopez, S.; Becker, G. D.; Berg, T. A. M.; Christensen, L.; Denney, K. D.; Hamann, F.; Paris, I.; Vestergaard, M.; Worseck, G.
2018-03-01
The quasars in our sample have been originally selected and observed in a new Legacy Survey, hereafter 'XQ-100', of 100 quasars at emission redshift zem=3.5-4.5 (ESO Large Programme 189.A-0424). The observations have been carried out with X-shooter/VLT (Vernet et al., 2011A&A...536A.105V). The released spectra provide a complete coverage from the atmospheric cut-off to the NIR with a spectral resolution R~6000-9000 depending on wavelength, and a median S/N~30 at the continuum level. XQ-100 provides the first large intermediate-resolution sample of high-redshift quasars with simultaneous rest-frame UV/optical coverage. A full description of the target selection, observations, and data reduction process is presented by Lopez et al. (2016A&A...594A..91L). (2 data files).
Environmental metabarcodes for insects: in silico PCR reveals potential for taxonomic bias.
Clarke, Laurence J; Soubrier, Julien; Weyrich, Laura S; Cooper, Alan
2014-11-01
Studies of insect assemblages are suited to the simultaneous DNA-based identification of multiple taxa known as metabarcoding. To obtain accurate estimates of diversity, metabarcoding markers ideally possess appropriate taxonomic coverage to avoid PCR-amplification bias, as well as sufficient sequence divergence to resolve species. We used in silico PCR to compare the taxonomic coverage and resolution of newly designed insect metabarcodes (targeting 16S) with that of existing markers [16S and cytochrome oxidase c subunit I (COI)] and then compared their efficiency in vitro. Existing metabarcoding primers amplified in silico <75% of insect species with complete mitochondrial genomes available, whereas new primers targeting 16S provided >90% coverage. Furthermore, metabarcodes targeting COI appeared to introduce taxonomic PCR-amplification bias, typically amplifying a greater percentage of Lepidoptera and Diptera species, while failing to amplify certain orders in silico. To test whether bias predicted in silico was observed in vitro, we created an artificial DNA blend containing equal amounts of DNA from 14 species, representing 11 insect orders and one arachnid. We PCR-amplified the blend using five primer sets, targeting either COI or 16S, with high-throughput amplicon sequencing yielding more than 6 million reads. In vitro results typically corresponded to in silico PCR predictions, with newly designed 16S primers detecting 11 insect taxa present, thus providing equivalent or better taxonomic coverage than COI metabarcodes. Our results demonstrate that in silico PCR is a useful tool for predicting taxonomic bias in mixed template PCR and that researchers should be wary of potential bias when selecting metabarcoding markers. © 2014 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Howard, Ward S.; Law, Nicholas M.; Ziegler, Carl A.; Baranec, Christoph; Riddle, Reed
2018-02-01
Adaptive optics laser guide-star systems perform atmospheric correction of stellar wavefronts in two parts: stellar tip-tilt and high-spatial-order laser correction. The requirement of a sufficiently bright guide star in the field-of-view to correct tip-tilt limits sky coverage. In this paper, we show an improvement to effective seeing without the need for nearby bright stars, enabling full sky coverage by performing only laser-assisted wavefront correction. We used Robo-AO, the first robotic AO system, to comprehensively demonstrate this laser-only correction. We analyze observations from four years of efficient robotic operation covering 15000 targets and 42000 observations, each realizing different seeing conditions. Using an autoguider (or a post-processing software equivalent) and the laser to improve effective seeing independent of the brightness of a target, Robo-AO observations show a 39% ± 19% improvement to effective FWHM, without any tip-tilt correction. We also demonstrate that 50% encircled energy performance without tip-tilt correction remains comparable to diffraction-limited, standard Robo-AO performance. Faint-target science programs primarily limited by 50% encircled energy (e.g., those employing integral field spectrographs placed behind the AO system) may see significant benefits to sky coverage from employing laser-only AO.
Fujimoto, Koya; Shiinoki, Takehiro; Yuasa, Yuki; Hanazawa, Hideki; Shibuya, Keiko
2017-06-01
A commercially available bolus ("commercial-bolus") does not make complete contact with the irregularly shaped patient skin. This study aims to customise a patient-specific three-dimensional (3D) bolus using a 3D printing technique ("3D-bolus") and to evaluate its clinical feasibility for photon radiotherapy. The 3D-bolus was designed using a treatment planning system (TPS) in Digital Imaging and Communications in Medicine-Radiotherapy (DICOM-RT) format, and converted to stereolithographic format for printing. To evaluate its physical characteristics, treatment plans were created for water-equivalent phantoms that were bolus-free, or had a flat-form printed 3D-bolus, a TPS-designed bolus ("virtual-bolus"), or a commercial-bolus. These plans were compared based on the percentage depth dose (PDD) and target-volume dose volume histogram (DVH) measurements. To evaluate the clinical feasibility, treatment plans were created for head phantoms that were bolus-free or had a 3D-bolus, a virtual-bolus, or a commercial-bolus. These plans were compared based on the target volume DVH. In the physical evaluation, the 3D-bolus provided effective dose coverage in the build-up region, which was equivalent to the commercial-bolus. With regard to the clinical feasibility, the air gaps were lesser with the 3D-bolus when compared to the commercial-bolus. Furthermore, the prescription dose could be delivered appropriately to the target volume. The 3D-bolus has potential use for air-gap reduction compared to the commercial-bolus and facilitates target-volume dose coverage and homogeneity improvement. A 3D-bolus produced using a 3D printing technique is comparable to a commercial-bolus applied to an irregular-shaped skin surface. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Electron intensity modulation for mixed-beam radiation therapy with an x-ray multi-leaf collimator
NASA Astrophysics Data System (ADS)
Weinberg, Rebecca
The current standard treatment for head and neck cancer at our institution uses intensity-modulated x-ray therapy (IMRT), which improves target coverage and sparing of critical structures by delivering complex fluence patterns from a variety of beam directions to conform dose distributions to the shape of the target volume. The standard treatment for breast patients is field-in-field forward-planned IMRT, with initial tangential fields and additional reduced-weight tangents with blocking to minimize hot spots. For these treatment sites, the addition of electrons has the potential of improving target coverage and sparing of critical structures due to rapid dose falloff with depth and reduced exit dose. In this work, the use of mixed-beam therapy (MBT), i.e., combined intensity-modulated electron and x-ray beams using the x-ray multi-leaf collimator (MLC), was explored. The hypothesis of this study was that addition of intensity-modulated electron beams to existing clinical IMRT plans would produce MBT plans that were superior to the original IMRT plans for at least 50% of selected head and neck and 50% of breast cases. Dose calculations for electron beams collimated by the MLC were performed with Monte Carlo methods. An automation system was created to facilitate communication between the dose calculation engine and the treatment planning system. Energy and intensity modulation of the electron beams was accomplished by dividing the electron beams into 2x2-cm2 beamlets, which were then beam-weight optimized along with intensity-modulated x-ray beams. Treatment plans were optimized to obtain equivalent target dose coverage, and then compared with the original treatment plans. MBT treatment plans were evaluated by participating physicians with respect to target coverage, normal structure dose, and overall plan quality in comparison with original clinical plans. The physician evaluations did not support the hypothesis for either site, with MBT selected as superior in 1 out of the 15 head and neck cases (p=1) and 6 out of 18 breast cases (p=0.95). While MBT was not shown to be superior to IMRT, reductions were observed in doses to critical structures distal to the target along the electron beam direction and to non-target tissues, at the expense of target coverage and dose homogeneity.
42 CFR 457.430 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Benchmark-equivalent health benefits coverage. 457.430 Section 457.430 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STATE CHILDREN'S HEALTH INSURANCE PROGRAMS (SCHIPs) ALLOTMENTS AND GRANTS TO...
42 CFR 457.430 - Benchmark-equivalent health benefits coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Benchmark-equivalent health benefits coverage. 457.430 Section 457.430 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STATE CHILDREN'S HEALTH INSURANCE PROGRAMS (SCHIPs) ALLOTMENTS AND GRANTS TO...
42 CFR 440.370 - Economy and efficiency.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Economy and efficiency. 440.370 Section 440.370...-Equivalent Coverage § 440.370 Economy and efficiency. Benchmark and benchmark-equivalent coverage and any... requirements and other economy and efficiency principles that would otherwise be applicable to the services or...
42 CFR 440.370 - Economy and efficiency.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 4 2013-10-01 2013-10-01 false Economy and efficiency. 440.370 Section 440.370...-Equivalent Coverage § 440.370 Economy and efficiency. Benchmark and benchmark-equivalent coverage and any... requirements and other economy and efficiency principles that would otherwise be applicable to the services or...
42 CFR 440.370 - Economy and efficiency.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Economy and efficiency. 440.370 Section 440.370...-Equivalent Coverage § 440.370 Economy and efficiency. Benchmark and benchmark-equivalent coverage and any... requirements and other economy and efficiency principles that would otherwise be applicable to the services or...
42 CFR 440.370 - Economy and efficiency.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Economy and efficiency. 440.370 Section 440.370...-Equivalent Coverage § 440.370 Economy and efficiency. Benchmark and benchmark-equivalent coverage and any... requirements and other economy and efficiency principles that would otherwise be applicable to the services or...
40 CFR 30.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 30.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
40 CFR 30.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 30.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
32 CFR 32.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 32.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
32 CFR 32.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 32.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
32 CFR 32.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 32.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
38 CFR 49.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 49.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
36 CFR 1210.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 1210.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for...
36 CFR 1210.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 1210.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for...
38 CFR 49.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 49.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
40 CFR 30.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 30.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
32 CFR 32.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 32.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
36 CFR 1210.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 1210.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for...
36 CFR 1210.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 1210.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for...
40 CFR 30.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 30.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
38 CFR 49.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 49.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
38 CFR 49.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 49.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
32 CFR 32.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 32.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
38 CFR 49.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 49.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
40 CFR 30.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 30.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
24 CFR 84.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 84.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
22 CFR 145.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 145.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
14 CFR 1260.131 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Higher Education, Hospitals, and Other Non-Profit Organizations Property Standards § 1260.131 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and...
14 CFR 1260.131 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Higher Education, Hospitals, and Other Non-Profit Organizations Property Standards § 1260.131 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and...
22 CFR 145.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 145.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
22 CFR 145.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 145.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
14 CFR 1260.131 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Higher Education, Hospitals, and Other Non-Profit Organizations Property Standards § 1260.131 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and...
22 CFR 145.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 145.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
24 CFR 84.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 84.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
2 CFR 215.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-01-01
... NON-PROFIT ORGANIZATIONS (OMB CIRCULAR A-110) Post Award Requirements Property Standards § 215.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
24 CFR 84.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 84.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
24 CFR 84.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 84.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
14 CFR 1260.131 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Higher Education, Hospitals, and Other Non-Profit Organizations Property Standards § 1260.131 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and...
22 CFR 145.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 145.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
24 CFR 84.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-04-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 84.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real...
42 CFR 440.330 - Benchmark health benefits coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Benchmark health benefits coverage. 440.330 Section 440.330 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Benchmark-Equivalent Coverage § 440.330 Benchmark health benefits coverage. Benchmark coverage is health...
36 CFR § 1210.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 1210.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for...
14 CFR § 1260.131 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Higher Education, Hospitals, and Other Non-Profit Organizations Property Standards § 1260.131 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-26
... coverage \\1\\ in the individual and small group markets, Medicaid benchmark and benchmark-equivalent plans...) Act extends the coverage of the EHB package to issuers of non-grandfathered individual and small group... small group markets, and not to Medicaid benchmark or benchmark-equivalent plans. EHB applicability to...
Exploring the relationship between population density and maternal health coverage.
Hanlon, Michael; Burstein, Roy; Masters, Samuel H; Zhang, Raymond
2012-11-21
Delivering health services to dense populations is more practical than to dispersed populations, other factors constant. This engenders the hypothesis that population density positively affects coverage rates of health services. This hypothesis has been tested indirectly for some services at a local level, but not at a national level. We use cross-sectional data to conduct cross-country, OLS regressions at the national level to estimate the relationship between population density and maternal health coverage. We separately estimate the effect of two measures of density on three population-level coverage rates (6 tests in total). Our coverage indicators are the fraction of the maternal population completing four antenatal care visits and the utilization rates of both skilled birth attendants and in-facility delivery. The first density metric we use is the percentage of a population living in an urban area. The second metric, which we denote as a density score, is a relative ranking of countries by population density. The score's calculation discounts a nation's uninhabited territory under the assumption those areas are irrelevant to service delivery. We find significantly positive relationships between our maternal health indicators and density measures. On average, a one-unit increase in our density score is equivalent to a 0.2% increase in coverage rates. Countries with dispersed populations face higher burdens to achieve multinational coverage targets such as the United Nations' Millennial Development Goals.
45 CFR 74.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 45 Public Welfare 1 2014-10-01 2014-10-01 false Insurance coverage. 74.31 Section 74.31 Public..., AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Property Standards § 74.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
45 CFR 74.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 1 2010-10-01 2010-10-01 false Insurance coverage. 74.31 Section 74.31 Public..., AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Property Standards § 74.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment...
10 CFR 600.131 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Insurance coverage. 600.131 Section 600.131 Energy... Nonprofit Organizations Post-Award Requirements § 600.131 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired with DOE funds as...
2 CFR 215.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 2 Grants and Agreements 1 2011-01-01 2011-01-01 false Insurance coverage. 215.31 Section 215.31... A-110) Post Award Requirements Property Standards § 215.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired with...
29 CFR 95.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 1 2012-07-01 2012-07-01 false Insurance coverage. 95.31 Section 95.31 Labor Office of the Secretary of Labor GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON... § 95.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage...
29 CFR 95.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 1 2014-07-01 2013-07-01 true Insurance coverage. 95.31 Section 95.31 Labor Office of the Secretary of Labor GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON... § 95.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage...
29 CFR 95.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 1 2013-07-01 2013-07-01 false Insurance coverage. 95.31 Section 95.31 Labor Office of the Secretary of Labor GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON... § 95.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage...
29 CFR 95.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 1 2010-07-01 2010-07-01 true Insurance coverage. 95.31 Section 95.31 Labor Office of the Secretary of Labor GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON... § 95.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage...
29 CFR 95.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 1 2011-07-01 2011-07-01 false Insurance coverage. 95.31 Section 95.31 Labor Office of the Secretary of Labor GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON... § 95.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage...
41 CFR 105-72.401 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Insurance coverage. 105... § 105-72.401 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to property owned by the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, C; Hrycushko, B; Jiang, S
2014-06-01
Purpose: To compare the radiobiological effect on large tumors and surrounding normal tissues from single fraction SRS, multi-fractionated SRT, and multi-staged SRS treatment. Methods: An anthropomorphic head phantom with a centrally located large volume target (18.2 cm{sup 3}) was scanned using a 16 slice large bore CT simulator. Scans were imported to the Multiplan treatment planning system where a total prescription dose of 20Gy was used for a single, three staged and three fractionated treatment. Cyber Knife treatment plans were inversely optimized for the target volume to achieve at least 95% coverage of the prescription dose. For the multistage plan,more » the target was segmented into three subtargets having similar volume and shape. Staged plans for individual subtargets were generated based on a planning technique where the beam MUs of the original plan on the total target volume are changed by weighting the MUs based on projected beam lengths within each subtarget. Dose matrices for each plan were export in DICOM format and used to calculate equivalent dose distributions in 2Gy fractions using an alpha beta ratio of 10 for the target and 3 for normal tissue. Results: Singe fraction SRS, multi-stage plan and multi-fractionated SRT plans had an average 2Gy dose equivalent to the target of 62.89Gy, 37.91Gy and 33.68Gy, respectively. The normal tissue within 12Gy physical dose region had an average 2Gy dose equivalent of 29.55Gy, 16.08Gy and 13.93Gy, respectively. Conclusion: The single fraction SRS plan had the largest predicted biological effect for the target and the surrounding normal tissue. The multi-stage treatment provided for a more potent biologically effect on target compared to the multi-fraction SRT treatments with less biological normal tissue than single-fraction SRS treatment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sakanaka, Katsuyuki; Mizowaki, Takashi, E-mail: mizo@kuhp.kyoto-u.ac.jp; Hiraoka, Masahiro
Purpose: To investigate the dosimetric advantage of intensity-modulated radiotherapy (IMRT) for whole ventricles (WV) in patients with a localized intracranial germinoma receiving induction chemotherapy. Methods and Materials: Data from 12 consecutive patients with localized intracranial germinomas who received induction chemotherapy and radiotherapy were used. Four-field coplanar three-dimensional conformal radiotherapy (3D-CRT) and seven-field coplanar IMRT plans were created. In both plans, 24 Gy was prescribed in 12 fractions for the planning target volume (PTV) involving WV and tumor bed. In IMRT planning, optimization was conducted to reduce the doses to the organs at risk (OARs) as much as possible, keeping themore » minimum dose equivalent to that of 3D-CRT. The 3D-CRT and IMRT plans were compared in terms of the dose-volume statistics for target coverage and the OARs. Results: IMRT significantly increased the percentage volume of the PTV receiving 24 Gy compared with 3D-CRT (93.5% vs. 84.8%; p = 0.007), while keeping target homogeneity equivalent to 3D-CRT (p = 0.869). The absolute percentage reduction in the irradiated volume of the normal brain receiving 100%, 75%, 50%, and 25% of 24 Gy ranged from 0.7% to 16.0% in IMRT compared with 3D-CRT (p < 0.001). No significant difference was observed in the volume of the normal brain receiving 10% and 5% of 24 Gy between IMRT and 3D-CRT. Conformation number was significantly improved in IMRT (p < 0.001). For other OARs, the mean dose to the cochlea was reduced significantly in IMRT by 22.3% of 24 Gy compared with 3D-CRT (p < 0.001). Conclusions: Compared with 3D-CRT, IMRT for WV improved the target coverage and reduced the irradiated volume of the normal brain in patients with intracranial germinomas receiving induction chemotherapy. IMRT for WV with induction chemotherapy could reduce the late side effects from cranial irradiation without compromising control of the tumor.« less
Exploring the relationship between population density and maternal health coverage
2012-01-01
Background Delivering health services to dense populations is more practical than to dispersed populations, other factors constant. This engenders the hypothesis that population density positively affects coverage rates of health services. This hypothesis has been tested indirectly for some services at a local level, but not at a national level. Methods We use cross-sectional data to conduct cross-country, OLS regressions at the national level to estimate the relationship between population density and maternal health coverage. We separately estimate the effect of two measures of density on three population-level coverage rates (6 tests in total). Our coverage indicators are the fraction of the maternal population completing four antenatal care visits and the utilization rates of both skilled birth attendants and in-facility delivery. The first density metric we use is the percentage of a population living in an urban area. The second metric, which we denote as a density score, is a relative ranking of countries by population density. The score’s calculation discounts a nation’s uninhabited territory under the assumption those areas are irrelevant to service delivery. Results We find significantly positive relationships between our maternal health indicators and density measures. On average, a one-unit increase in our density score is equivalent to a 0.2% increase in coverage rates. Conclusions Countries with dispersed populations face higher burdens to achieve multinational coverage targets such as the United Nations’ Millennial Development Goals. PMID:23170895
MCMC-ODPR: primer design optimization using Markov Chain Monte Carlo sampling.
Kitchen, James L; Moore, Jonathan D; Palmer, Sarah A; Allaby, Robin G
2012-11-05
Next generation sequencing technologies often require numerous primer designs that require good target coverage that can be financially costly. We aimed to develop a system that would implement primer reuse to design degenerate primers that could be designed around SNPs, thus find the fewest necessary primers and the lowest cost whilst maintaining an acceptable coverage and provide a cost effective solution. We have implemented Metropolis-Hastings Markov Chain Monte Carlo for optimizing primer reuse. We call it the Markov Chain Monte Carlo Optimized Degenerate Primer Reuse (MCMC-ODPR) algorithm. After repeating the program 1020 times to assess the variance, an average of 17.14% fewer primers were found to be necessary using MCMC-ODPR for an equivalent coverage without implementing primer reuse. The algorithm was able to reuse primers up to five times. We compared MCMC-ODPR with single sequence primer design programs Primer3 and Primer-BLAST and achieved a lower primer cost per amplicon base covered of 0.21 and 0.19 and 0.18 primer nucleotides on three separate gene sequences, respectively. With multiple sequences, MCMC-ODPR achieved a lower cost per base covered of 0.19 than programs BatchPrimer3 and PAMPS, which achieved 0.25 and 0.64 primer nucleotides, respectively. MCMC-ODPR is a useful tool for designing primers at various melting temperatures at good target coverage. By combining degeneracy with optimal primer reuse the user may increase coverage of sequences amplified by the designed primers at significantly lower costs. Our analyses showed that overall MCMC-ODPR outperformed the other primer-design programs in our study in terms of cost per covered base.
MCMC-ODPR: Primer design optimization using Markov Chain Monte Carlo sampling
2012-01-01
Background Next generation sequencing technologies often require numerous primer designs that require good target coverage that can be financially costly. We aimed to develop a system that would implement primer reuse to design degenerate primers that could be designed around SNPs, thus find the fewest necessary primers and the lowest cost whilst maintaining an acceptable coverage and provide a cost effective solution. We have implemented Metropolis-Hastings Markov Chain Monte Carlo for optimizing primer reuse. We call it the Markov Chain Monte Carlo Optimized Degenerate Primer Reuse (MCMC-ODPR) algorithm. Results After repeating the program 1020 times to assess the variance, an average of 17.14% fewer primers were found to be necessary using MCMC-ODPR for an equivalent coverage without implementing primer reuse. The algorithm was able to reuse primers up to five times. We compared MCMC-ODPR with single sequence primer design programs Primer3 and Primer-BLAST and achieved a lower primer cost per amplicon base covered of 0.21 and 0.19 and 0.18 primer nucleotides on three separate gene sequences, respectively. With multiple sequences, MCMC-ODPR achieved a lower cost per base covered of 0.19 than programs BatchPrimer3 and PAMPS, which achieved 0.25 and 0.64 primer nucleotides, respectively. Conclusions MCMC-ODPR is a useful tool for designing primers at various melting temperatures at good target coverage. By combining degeneracy with optimal primer reuse the user may increase coverage of sequences amplified by the designed primers at significantly lower costs. Our analyses showed that overall MCMC-ODPR outperformed the other primer-design programs in our study in terms of cost per covered base. PMID:23126469
Kralik, John C.; Xi, Liwen; Solberg, Timothy D.; Simone, Charles B.
2015-01-01
Target coverage and organ‐at‐risk sparing were compared for 22 pediatric patients with primary brain tumors treated using two distinct nozzles in pencil beam scanning (PBS) proton therapy. Consecutive patients treated at our institution using a PBS‐dedicated nozzle (DN) were replanned using a universal nozzle (UN) beam model and the original DN plan objectives. Various cranial sites were treated among the patients to prescription doses ranging from 45 to 54 Gy. Organs at risk (OARs) evaluated were patient‐dependent; 15 unique OARs were analyzed, all of which were assessed in at least 10 patients. Clinical target volume (CTV) coverage and organ sparing were compared for the two nozzles using dose‐volume histogram data. Statistical analysis using a confidence‐interval approach demonstrates that CTV coverage is equivalent for UN and DN plans within ±5% equivalence bounds. In contrast, average mean and maximum doses are significantly higher for nearly all 15 OARs in the UN plans. The average median increase over all OARs and patients is approximately 1.7 Gy, with an increase in the 25%–75% of 1.0–2.3 Gy; the median increase to the pituitary gland, temporal lobes, eyes and cochleas are 1.8, 1.7, 0.7, and 2.7 Gy, respectively. The CTV dose distributions fall off slower for UN than for the DN plans; hence, normal tissue structures in close proximity to CTVs receive higher doses in UN plans than in DN plans. The higher OAR doses in the UN plans are likely due to the larger spot profile in plans created with UN beams. In light of the high rates of toxicities in pediatric patients receiving cranial irradiation and in light of selected brain tumor types having high cure rates, this study suggests the smaller DN beam profile is preferable for the advantage of reducing dose to OARs. PACS number: 87.55.D‐ PMID:26699553
Reference drug programs: effectiveness and policy implications.
Schneeweiss, Sebastian
2007-04-01
In the current economic environment, health care systems are constantly struggling to contain rapidly rising costs. Drug costs are targeted by a wide variety of measures. Many jurisdictions have implemented reference drug programs (RDPs) or similar therapeutic substitution programs. This paper summarizes the mechanism and rationale of RDPs and presents evidence of their economic effectiveness and clinical safety. RDPs for pharmaceutical reimbursement are based on the assumption that drugs within specified medication groups are therapeutically equivalent and clinically interchangeable and that a common reimbursement level can thus be established. If the evidence documents that a higher price for a given drug does not buy greater effectiveness or reduced toxicity, then under RDP such extra costs are not covered. RDPs or therapeutic substitutions based on therapeutic equivalence are seen as logical extensions of generic substitution that is based on bioequivalence of drugs. If the goal is to achieve full drug coverage for as many patients as possible in the most efficient manner, then RDPs in combination with prior authorization programs are safer and more effective than simplistic fiscal drug policies, including fixed co-payments, co-insurances, or deductibles. RDPs will reduce spending in the less innovative but largest market, while fully covering all patients. Prior authorization will ensure that patients with a specified indication will benefit from the most innovative therapies with full coverage. In practice, however, not all patients and drugs will fit exactly into one of the two categories. Therefore, a process of medically indicated exemptions that will consider full coverage should accompany an RDP. In the current economic environment, health care systems are constantly struggling to contain rapidly rising costs. Drug costs are targeted by a wide variety of measures. Many jurisdictions have implemented reference drug programs, and others are considering them. This paper summarizes the mechanism and rationale of RDPs, presents evidence of their economic effectiveness and clinical safety, and concludes with some practical implications of implementing RDP policies.
Reference drug programs: Effectiveness and policy implications☆
Schneeweiss, Sebastian
2010-01-01
In the current economic environment, health care systems are constantly struggling to contain rapidly rising costs. Drug costs are targeted by a wide variety of measures. Many jurisdictions have implemented reference drug programs (RDPs) or similar therapeutic substitution programs. This paper summarizes the mechanism and rationale of RDPs and presents evidence of their economic effectiveness and clinical safety. RDPs for pharmaceutical reimbursement are based on the assumption that drugs within specified medication groups are therapeutically equivalent and clinically interchangeable and that a common reimbursement level can thus be established. If the evidence documents that a higher price for a given drug does not buy greater effectiveness or reduced toxicity, then under RDP such extra costs are not covered. RDPs or therapeutic substitutions based on therapeutic equivalence are seen as logical extensions of generic substitution that is based on bioequivalence of drugs. If the goal is to achieve full drug coverage for as many patients as possible in the most efficient manner, then RDPs in combination with prior authorization programs are safer and more effective than simplistic fiscal drug policies, including fixed co-payments, co-insurances, or deductibles. RDPs will reduce spending in the less innovative but largest market, while fully covering all patients. Prior authorization will ensure that patients with a specified indication will benefit from the most innovative therapies with full coverage. In practice, however, not all patients and drugs will fit exactly into one of the two categories. Therefore, a process of medically indicated exemptions that will consider full coverage should accompany an RDP. In the current economic environment, health care systems are constantly struggling to contain rapidly rising costs. Drug costs are targeted by a wide variety of measures. Many jurisdictions have implemented reference drug programs, and others are considering them. This paper summarizes the mechanism and rationale of RDPs, presents evidence of their economic effectiveness and clinical safety, and concludes with some practical implications of implementing RDP policies. PMID:16777256
20 CFR 404.1913 - Precluding dual coverage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... precluding dual coverage to avoid inequitable or anomalous coverage situations for certain workers. However... 404.1913 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY...) General. Employment or self-employment or services recognized as equivalent under the Act or the social...
Global investment targets for malaria control and elimination between 2016 and 2030
Patouillard, Edith; Griffin, Jamie; Bhatt, Samir; Ghani, Azra; Cibulskis, Richard
2017-01-01
Background Access to malaria control interventions falls short of universal health coverage. The Global Technical Strategy for malaria targets at least 90% reduction in case incidence and mortality rates, and elimination in 35 countries by 2030. The potential to reach these targets will be determined in part by investments in malaria. This study estimates the financing required for malaria control and elimination over the 2016–2030 period. Methods A mathematical transmission model was used to explore the impact of increasing intervention coverage on burden and costs. The cost analysis took a public provider perspective covering all 97 malaria endemic countries and territories in 2015. All control interventions currently recommended by the WHO were considered. Cost data were sourced from procurement databases, the peer-reviewed literature, national malaria strategic plans, the WHO-CHOICE project and key informant interviews. Results Annual investments of $6.4 billion (95% uncertainty interval (UI $4.5–$9.0 billion)) by 2020, $7.7 billion (95% UI $5.4–$10.9 billion) by 2025 and $8.7 billion (95% UI $6.0–$12.3 billion) by 2030 will be required to reach the targets set in the Global Technical Strategy. These are equivalent to annual investment per person at risk of malaria of US$3.90 by 2020, US$4.30 by 2025 and US$4.40 by 2030, compared with US$2.30 if interventions were sustained at current coverage levels. The 20 countries with the highest burden in 2015 will require 88% of the total investment. Conclusions Given the challenges in increasing domestic and international funding, the efficient use of currently available resources should be a priority. PMID:29242750
Global investment targets for malaria control and elimination between 2016 and 2030.
Patouillard, Edith; Griffin, Jamie; Bhatt, Samir; Ghani, Azra; Cibulskis, Richard
2017-01-01
Access to malaria control interventions falls short of universal health coverage. The Global Technical Strategy for malaria targets at least 90% reduction in case incidence and mortality rates, and elimination in 35 countries by 2030. The potential to reach these targets will be determined in part by investments in malaria. This study estimates the financing required for malaria control and elimination over the 2016-2030 period. A mathematical transmission model was used to explore the impact of increasing intervention coverage on burden and costs. The cost analysis took a public provider perspective covering all 97 malaria endemic countries and territories in 2015. All control interventions currently recommended by the WHO were considered. Cost data were sourced from procurement databases, the peer-reviewed literature, national malaria strategic plans, the WHO-CHOICE project and key informant interviews. Annual investments of $6.4 billion (95% uncertainty interval (UI $4.5-$9.0 billion)) by 2020, $7.7 billion (95% UI $5.4-$10.9 billion) by 2025 and $8.7 billion (95% UI $6.0-$12.3 billion) by 2030 will be required to reach the targets set in the Global Technical Strategy. These are equivalent to annual investment per person at risk of malaria of US$3.90 by 2020, US$4.30 by 2025 and US$4.40 by 2030, compared with US$2.30 if interventions were sustained at current coverage levels. The 20 countries with the highest burden in 2015 will require 88% of the total investment. Given the challenges in increasing domestic and international funding, the efficient use of currently available resources should be a priority.
45 CFR 2543.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
20 CFR 435.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT ORGANIZATIONS, AND COMMERCIAL... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
45 CFR 2543.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
7 CFR 3019.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-01-01
... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 3019.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
20 CFR 435.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT ORGANIZATIONS, AND COMMERCIAL... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
7 CFR 3019.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-01-01
... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 3019.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
20 CFR 435.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT ORGANIZATIONS, AND COMMERCIAL... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
7 CFR 3019.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-01-01
... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 3019.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
20 CFR 435.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT ORGANIZATIONS, AND COMMERCIAL... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
7 CFR 3019.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-01-01
... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 3019.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
45 CFR 2543.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
20 CFR 435.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT ORGANIZATIONS, AND COMMERCIAL... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
7 CFR 3019.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 3019.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
45 CFR 2543.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
45 CFR 2543.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT... minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal...
28 CFR 70.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... AND AGREEMENTS (INCLUDING SUBAWARDS) WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS AND OTHER NON... must, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
34 CFR 74.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 74.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent...
43 CFR 12.931 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... With Institutions of Higher Education, Hospitals, and Other Non-Profit Organizations Post-Award Requirements § 12.931 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
28 CFR 70.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... AND AGREEMENTS (INCLUDING SUBAWARDS) WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS AND OTHER NON... must, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
34 CFR 74.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 74.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent...
28 CFR 70.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... AND AGREEMENTS (INCLUDING SUBAWARDS) WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS AND OTHER NON... must, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
34 CFR 74.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 74.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent...
43 CFR 12.931 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... With Institutions of Higher Education, Hospitals, and Other Non-Profit Organizations Post-Award Requirements § 12.931 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
34 CFR 74.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 74.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent...
28 CFR 70.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... AND AGREEMENTS (INCLUDING SUBAWARDS) WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS AND OTHER NON... must, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
34 CFR 74.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 74.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent...
43 CFR 12.931 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... With Institutions of Higher Education, Hospitals, and Other Non-Profit Organizations Post-Award Requirements § 12.931 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
28 CFR 70.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... AND AGREEMENTS (INCLUDING SUBAWARDS) WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS AND OTHER NON... must, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
43 CFR 12.931 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... With Institutions of Higher Education, Hospitals, and Other Non-Profit Organizations Post-Award Requirements § 12.931 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
43 CFR 12.931 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... With Institutions of Higher Education, Hospitals, and Other Non-Profit Organizations Post-Award Requirements § 12.931 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
2 CFR 215.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS (OMB CIRCULAR... a minimum, provide the equivalent insurance coverage for real property and equipment acquired with...
10 CFR 600.131 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Nonprofit Organizations Post-Award Requirements § 600.131 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired with DOE funds as provided to property owned by the recipient. Federally-owned property need not be insured unless required...
10 CFR 600.131 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Nonprofit Organizations Post-Award Requirements § 600.131 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired with DOE funds as provided to property owned by the recipient. Federally-owned property need not be insured unless required...
10 CFR 600.131 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Nonprofit Organizations Post-Award Requirements § 600.131 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired with DOE funds as provided to property owned by the recipient. Federally-owned property need not be insured unless required...
22 CFR 226.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 22 Foreign Relations 1 2012-04-01 2012-04-01 false Insurance coverage. 226.31 Section 226.31 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
22 CFR 226.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Insurance coverage. 226.31 Section 226.31 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
22 CFR 226.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Insurance coverage. 226.31 Section 226.31 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
22 CFR 226.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Insurance coverage. 226.31 Section 226.31 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
22 CFR 226.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Insurance coverage. 226.31 Section 226.31 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, L; Dong, P; Larson, D
Purpose: To investigate a new modulated beam orientation optimization (MBOO) approach maximizing treatment planning quality for the state-of-the-art flattening filter free (FFF) beam that has enabled rapid treatments of multiple brain targets. Methods: MBOO selects and optimizes a large number of intensity-modulated beams (400 or more) from all accessible beam angles surrounding a patient’s skull. The optimization algorithm was implemented on a standalone system that interfaced with the 3D Dicom images and structure sets. A standard published data set that consisted of 1 to 12 metastatic brain tumor combinations was selected for MBOO planning. The planning results from various coplanarmore » and non-coplanar configurations via MBOO were then compared with the results obtained from a clinical volume modulated arc therapy (VMAT) delivery system (Truebeam RapidArc, Varian Oncology). Results: When planning a few number of targets (n<4), MBOO produced results equivalent to non-coplanar multi-arc VMAT planning in terms of target volume coverage and normal tissue sparing. For example, the 12-Gy and 4-Gy normal brain volumes for the 3-target plans differed by less than 1 mL ( 3.0 mLvs 3.8 mL; and 35.2 mL vs 36.3 mL, respectively) for MBOO versus VMAT. However, when planning a larger number of targets (n≥4), MBOO significantly reduced the dose to the normal brain as compared to VMAT, though the target volume coverage was equivalent. For example, the 12-Gy and 4-Gy normal brain volumes for the 12-target plans were 10.8 mL vs. 18.0 mL and 217.9 mL vs. 390.0 mL, respectively for the non-coplanar MBOO versus the non-coplanar VMAT treatment plans, yielding a reduction in volume of more than 60% for the case. Conclusion: MBOO is a unique approach for maximizing normal tissue sparing when treating a large number (n≥4) of brain tumors with FFF linear accelerators. Dr Ma and Dr Sahgal are currently on the board of international society of stereotactic radiosurgery. Dr Sahgal has received support for educational presentations from Elekta company.« less
22 CFR 518.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
15 CFR 14.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-01-01
... FOR GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT, AND... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
15 CFR 14.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-01-01
... FOR GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT, AND... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
22 CFR 518.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
49 CFR 19.31 - Insurance coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
22 CFR 518.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
49 CFR 19.31 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
22 CFR 518.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
22 CFR 518.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-04-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
15 CFR 14.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... FOR GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT, AND... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
49 CFR 19.31 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
15 CFR 14.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-01-01
... FOR GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT, AND... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
49 CFR 19.31 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
15 CFR 14.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-01-01
... FOR GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT, AND... shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired...
49 CFR 19.31 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award... equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to...
41 CFR 105-72.401 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-01-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS 72.40-Post-Award Requirements/Property Standards § 105-72.401 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
41 CFR 105-72.401 - Insurance coverage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS 72.40-Post-Award Requirements/Property Standards § 105-72.401 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
41 CFR 105-72.401 - Insurance coverage.
Code of Federal Regulations, 2012 CFR
2012-01-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS 72.40-Post-Award Requirements/Property Standards § 105-72.401 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
41 CFR 105-72.401 - Insurance coverage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS 72.40-Post-Award Requirements/Property Standards § 105-72.401 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krayenbuehl, Jerome; Hartmann, Matthias; Lomax, Anthony J.
Purpose: To perform comparative planning for intensity-modulated radiotherapy (IMRT) and proton therapy (PT) for malignant pleural mesothelioma after radical surgery. Methods and Materials: Eight patients treated with IMRT after extrapleural pleuropneumonectomy (EPP) were replanned for PT, comparing dose homogeneity, target volume coverage, and mean and maximal dose to organs at risk. Feasibility of PT was evaluated regarding the dose distribution with respect to air cavities after EPP. Results: Dose coverage and dose homogeneity of the planning target volume (PTV) were significantly better for PT than for IMRT regarding the volume covered by >95% (V95) for the high-dose PTV. The meanmore » dose to the contralateral kidney, ipsilateral kidney, contralateral lung, liver, and heart and spinal cord dose were significantly reduced with PT compared with IMRT. After EPP, air cavities were common (range, 0-850 cm{sup 3}), decreasing from 0 to 18.5 cm{sup 3}/day. In 2 patients, air cavity changes during RT decreased the generalized equivalent uniform dose (gEUD) in the case of using an a value of < - 10 to the PTV2 to <2 Gy in the presence of changing cavities for PT, and to 40 Gy for IMRT. Small changes were observed for gEUD of PTV1 because PTV1 was reached by the beams before air. Conclusion: Both PT and IMRT achieved good target coverage and dose homogeneity. Proton therapy accomplished additional dose sparing of most organs at risk compared with IMRT. Proton therapy dose distributions were more susceptible to changing air cavities, emphasizing the need for adaptive RT and replanning.« less
Abbas, Ahmar S; Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles
2013-05-06
Recently, volumetric-modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity-modulated fixed-field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs-at-risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed-field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient-specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single-arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2-T3 N0-N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281-601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four-field (n = 4) or five-field (n = 9) step-and-shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose-volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose, lung V20 and V5, liver V30, and Dmax to the spinal canal prv3mm. Also examined were the total plan monitor units (MUs) and the beam delivery time. Equivalent target coverage was observed with both VMAT single and two-arc plans. The comparison of VMATI with fixed-field IMRT demonstrated equivalent target coverage; statistically no significant difference were found in PTV D99 (p = 0.47), PTV mean (p = 0.12), PTV D95 and PTV V9547.5Gy (95%) (p = 0.38). However, Dmax in VMATI plans was significantly lower compared to IMRT (p = 0.02). The Van't Riet dose conformation number (CN) was also statistically in favor of VMATI plans (p = 0.04). VMATI achieved lower lung V20 (p = 0.05), whereas lung V5 (p = 0.35) and mean lung dose (p = 0.62) were not significantly different. The other OARs, including spinal canal, liver, heart, and kidneys showed no statistically significant differences between the two techniques. Treatment time delivery for VMATI plans was reduced by up to 55% (p = 5.8E-10) and MUs reduced by up to 16% (p = 0.001). Integral dose was not statistically different between the two planning techniques (p = 0.99). There were no statistically significant differences found in dose distribution of the two VMAT techniques (VMATI vs. VMATII) Dose statistics for both VMAT techniques were: PTV D99 (p = 0.76), PTV D95 (p = 0.95), mean PTV dose (p = 0.78), conformation number (CN) (p = 0.26), and MUs (p = 0.1). However, the treatment delivery time for VMATII increased significantly by two-fold (p = 3.0E-11) compared to VMATI. VMAT-based treatment planning is safe and deliverable for patients with thoracic esophageal cancer with similar planning goals, when compared to standard IMRT. The key benefit for VMATI was the reduction in treatment delivery time and MUs, and improvement in dose conformality. In our study, we found no significant difference in VMATII over single-arc VMATI for PTV coverage or OARs doses. However, we observed significant increase in delivery time for VMATII compared to VMATI.
Targeting a Complex Transcriptome: The Construction of the Mouse Full-Length cDNA Encyclopedia
Carninci, Piero; Waki, Kazunori; Shiraki, Toshiyuki; Konno, Hideaki; Shibata, Kazuhiro; Itoh, Masayoshi; Aizawa, Katsunori; Arakawa, Takahiro; Ishii, Yoshiyuki; Sasaki, Daisuke; Bono, Hidemasa; Kondo, Shinji; Sugahara, Yuichi; Saito, Rintaro; Osato, Naoki; Fukuda, Shiro; Sato, Kenjiro; Watahiki, Akira; Hirozane-Kishikawa, Tomoko; Nakamura, Mari; Shibata, Yuko; Yasunishi, Ayako; Kikuchi, Noriko; Yoshiki, Atsushi; Kusakabe, Moriaki; Gustincich, Stefano; Beisel, Kirk; Pavan, William; Aidinis, Vassilis; Nakagawara, Akira; Held, William A.; Iwata, Hiroo; Kono, Tomohiro; Nakauchi, Hiromitsu; Lyons, Paul; Wells, Christine; Hume, David A.; Fagiolini, Michela; Hensch, Takao K.; Brinkmeier, Michelle; Camper, Sally; Hirota, Junji; Mombaerts, Peter; Muramatsu, Masami; Okazaki, Yasushi; Kawai, Jun; Hayashizaki, Yoshihide
2003-01-01
We report the construction of the mouse full-length cDNA encyclopedia,the most extensive view of a complex transcriptome,on the basis of preparing and sequencing 246 libraries. Before cloning,cDNAs were enriched in full-length by Cap-Trapper,and in most cases,aggressively subtracted/normalized. We have produced 1,442,236 successful 3′-end sequences clustered into 171,144 groups, from which 60,770 clones were fully sequenced cDNAs annotated in the FANTOM-2 annotation. We have also produced 547,149 5′ end reads,which clustered into 124,258 groups. Altogether, these cDNAs were further grouped in 70,000 transcriptional units (TU),which represent the best coverage of a transcriptome so far. By monitoring the extent of normalization/subtraction, we define the tentative equivalent coverage (TEC),which was estimated to be equivalent to >12,000,000 ESTs derived from standard libraries. High coverage explains discrepancies between the very large numbers of clusters (and TUs) of this project,which also include non-protein-coding RNAs,and the lower gene number estimation of genome annotations. Altogether,5′-end clusters identify regions that are potential promoters for 8637 known genes and 5′-end clusters suggest the presence of almost 63,000 transcriptional starting points. An estimate of the frequency of polyadenylation signals suggests that at least half of the singletons in the EST set represent real mRNAs. Clones accounting for about half of the predicted TUs await further sequencing. The continued high-discovery rate suggests that the task of transcriptome discovery is not yet complete. PMID:12819125
42 CFR 440.390 - Assurance of transportation.
Code of Federal Regulations, 2014 CFR
2014-10-01
...-Equivalent Coverage § 440.390 Assurance of transportation. If a benchmark or benchmark-equivalent plan does... nevertheless assure that emergency and non-emergency transportation is covered for beneficiaries enrolled in the benchmark or benchmark-equivalent plan, as required under § 431.53 of this chapter. ...
42 CFR 440.390 - Assurance of transportation.
Code of Federal Regulations, 2012 CFR
2012-10-01
...-Equivalent Coverage § 440.390 Assurance of transportation. If a benchmark or benchmark-equivalent plan does... nevertheless assure that emergency and non-emergency transportation is covered for beneficiaries enrolled in the benchmark or benchmark-equivalent plan, as required under § 431.53 of this chapter. ...
42 CFR 440.390 - Assurance of transportation.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-Equivalent Coverage § 440.390 Assurance of transportation. If a benchmark or benchmark-equivalent plan does... nevertheless assure that emergency and non-emergency transportation is covered for beneficiaries enrolled in the benchmark or benchmark-equivalent plan, as required under § 431.53 of this chapter. ...
42 CFR 440.390 - Assurance of transportation.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-Equivalent Coverage § 440.390 Assurance of transportation. If a benchmark or benchmark-equivalent plan does... nevertheless assure that emergency and non-emergency transportation is covered for beneficiaries enrolled in the benchmark or benchmark-equivalent plan, as required under § 431.53 of this chapter. ...
42 CFR 440.390 - Assurance of transportation.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-Equivalent Coverage § 440.390 Assurance of transportation. If a benchmark or benchmark-equivalent plan does... nevertheless assure that emergency and non-emergency transportation is covered for beneficiaries enrolled in the benchmark or benchmark-equivalent plan, as required under § 431.53 of this chapter. ...
2 CFR 200.310 - Insurance coverage.
Code of Federal Regulations, 2014 CFR
2014-01-01
.... The non-Federal entity must, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired or improved with Federal funds as provided to property owned by the non-Federal...
Huang, Like; Xu, Jie; Sun, Xiaoxiang; Du, Yangyang; Cai, Hongkun; Ni, Jian; Li, Juan; Hu, Ziyang; Zhang, Jianjun
2016-04-20
Currently, most efficient perovskite solar cells (PVKSCs) with a p-i-n structure require simultaneously electron transport layers (ETLs) and hole transport layers (HTLs) to help collecting photogenerated electrons and holes for obtaining high performance. ETL free planar PVKSC is a relatively new and simple structured solar cell that gets rid of the complex and high temperature required ETL (such as compact and mesoporous TiO2). Here, we demonstrate the critical role of high coverage of perovskite in efficient ETL free PVKSCs from an energy band and equivalent circuit model perspective. From an electrical point of view, we confirmed that the low coverage of perovskite does cause localized short circuit of the device. With coverage optimization, a planar p-i-n(++) device with a power conversion efficiency of over 11% was achieved, implying that the ETL layer may not be necessary for an efficient device as long as the perovskite coverage is approaching 100%.
5 CFR 337.201 - Coverage and purpose.
Code of Federal Regulations, 2011 CFR
2011-01-01
... or nonpermanent position or group of positions in the competitive service at GS-15 (or equivalent... Officer (or equivalent) at the agency headquarters level. OPM will determine the length of the direct-hire...
5 CFR 337.201 - Coverage and purpose.
Code of Federal Regulations, 2010 CFR
2010-01-01
... or nonpermanent position or group of positions in the competitive service at GS-15 (or equivalent... Officer (or equivalent) at the agency headquarters level. OPM will determine the length of the direct-hire...
SU-E-T-314: Dosimetric Effect of Smooth Drilling On Proton Compensators in Prostate Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reyhan, M; Yue, N; Zou, J
2015-06-15
Purpose: To evaluate the dosimetric effect of smooth drilling of proton compensators in proton prostate plans when compared to typical plunge drilling settings. Methods: Twelve prostate patients were planned in Eclipse treatment planning system using three different drill settings Smooth, Plunge drill A, and Plunge drill B. The differences between A and B were: spacing X[cm]: 0.4(A), 0.1(B), spacing Y[cm]: 0.35(A), 0.1(B), row offset [cm]: 0.2(A), 0(B). Planning parameters were kept consistent between the different plans, which utilized two opposed lateral beams arrangement. Mean differences absolute dosimetry in OAR constraints are presented. Results: The smooth drilled compensator based plans yieldedmore » equivalent target coverage to the plans generated with drill settings A and B. Overall, the smooth compensators reduced dose to the majority of organs at risk compared to settings A and B. Constraints were reduced for the following OAR: Rectal V75 by 2.12 and 2.48%, V70 by 2.45 and 2.91%, V65 by 2.85 and 3.37%, V50 by 2.3 and 5.1%, Bladder V65 by 4.49 and 3.67%, Penial Bulb mean by 3.7 and 4.2Gy, and the maximum plan dose 5.3 and 7.4Gy for option A vs smooth and option B vs smooth respectively. The femoral head constraint (V50<5%) was met by all plans, but it was not consistently lower for the smooth drilling plan. Conclusion: Smooth drilled compensators provide equivalent target coverage and overall slightly cooler plans to the majority of organs at risk; it also minimizes the potential dosimetric impacts caused by patient positioning uncertainty.« less
On Connected Target k-Coverage in Heterogeneous Wireless Sensor Networks.
Yu, Jiguo; Chen, Ying; Ma, Liran; Huang, Baogui; Cheng, Xiuzhen
2016-01-15
Coverage and connectivity are two important performance evaluation indices for wireless sensor networks (WSNs). In this paper, we focus on the connected target k-coverage (CTC k) problem in heterogeneous wireless sensor networks (HWSNs). A centralized connected target k-coverage algorithm (CCTC k) and a distributed connected target k-coverage algorithm (DCTC k) are proposed so as to generate connected cover sets for energy-efficient connectivity and coverage maintenance. To be specific, our proposed algorithms aim at achieving minimum connected target k-coverage, where each target in the monitored region is covered by at least k active sensor nodes. In addition, these two algorithms strive to minimize the total number of active sensor nodes and guarantee that each sensor node is connected to a sink, such that the sensed data can be forwarded to the sink. Our theoretical analysis and simulation results show that our proposed algorithms outperform a state-of-art connected k-coverage protocol for HWSNs.
Horowitz, David P; Wang, Tony J C; Wuu, Cheng-Shie; Feng, Wenzheng; Drassinower, Daphnie; Lasala, Anita; Pieniazek, Radoslaw; Cheng, Simon; Connolly, Eileen P; Lassman, Andrew B
2014-11-01
We examined the fetal dose from irradiation of glioblastoma during pregnancy using intensity modulated radiation therapy (IMRT), and describe fetal dose minimization using mobile shielding devices. A case report is described of a pregnant woman with glioblastoma who was treated during the third trimester of gestation with 60 Gy of radiation delivered via a 6 MV photon IMRT plan. Fetal dose without shielding was estimated using an anthropomorphic phantom with ion chamber and diode measurements. Clinical fetal dose with shielding was determined with optically stimulated luminescent dosimeters and ion chamber. Clinical target volume (CTV) and planning target volume (PTV) coverage was 100 and 98 % receiving 95 % of the prescription dose, respectively. Normal tissue tolerances were kept below quantitative analysis of normal tissue effects in the clinic (QUANTEC) recommendations. Without shielding, anthropomorphic phantom measurements showed a cumulative fetal dose of 0.024 Gy. In vivo measurements with shielding in place demonstrated a cumulative fetal dose of 0.016 Gy. The fetal dose estimated without shielding was 0.04 % and with shielding was 0.026 % of the target dose. In vivo estimation of dose equivalent received by the fetus was 24.21 mSv. Using modern techniques, brain irradiation can be delivered to pregnant patients in the third trimester with very low measured doses to the fetus, without compromising target coverage or normal tissue dose constraints. Fetal dose can further be reduced with the use of shielding devices, in keeping with the principle of as low as reasonably achievable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenthal, David I., E-mail: dirosenthal@mdanderson.or; Fuller, Clifton D.; Barker, Jerry L.
2010-06-01
Purpose: To investigate the dosimetry and feasibility of carotid-sparing intensity-modulated radiotherapy (IMRT) for early glottic cancer and to report preliminary clinical experience. Methods and Materials: Digital Imaging and Communications in Medicine radiotherapy (DICOM-RT) datasets from 6 T1-2 conventionally treated glottic cancer patients were used to create both conventional IMRT plans. We developed a simplified IMRT planning algorithm with three fields and limited segments. Conventional and IMRT plans were compared using generalized equivalent uniform dose and dose-volume parameters for in-field carotid arteries, target volumes, and organs at risk. We have treated 11 patients with this simplified IMRT technique. Results: Intensity-modulated radiotherapymore » consistently reduced radiation dose to the carotid arteries (p < 0.05) while maintaining the clinical target volume coverage. With conventional planning, median carotid V35, V50, and V63 were 100%, 100%, and 69.0%, respectively. With IMRT planning these decreased to 2%, 0%, and 0%, respectively (p < 0.01). Radiation planning and treatment times were similar for conventional radiotherapy and IMRT. Treatment results have been excellent thus far. Conclusions: Intensity-modulated radiotherapy significantly reduced unnecessary radiation dose to the carotid arteries compared with conventional lateral fields while maintaining clinical target volume coverage. Further experience and longer follow-up will be required to demonstrate outcomes for cancer control and carotid artery effects.« less
Range optimization for mono- and bi-energetic proton modulated arc therapy with pencil beam scanning
NASA Astrophysics Data System (ADS)
Sanchez-Parcerisa, Daniel; Kirk, Maura; Fager, Marcus; Burgdorf, Brendan; Stowe, Malorie; Solberg, Tim; Carabe, Alejandro
2016-11-01
The development of rotational proton therapy plans based on a pencil-beam-scanning (PBS) system has been limited, among several other factors, by the energy-switching time between layers, a system-dependent parameter that ranges between a fraction of a second and several seconds. We are investigating mono- and bi-energetic rotational proton modulated arc therapy (PMAT) solutions that would not be affected by long energy switching times. In this context, a systematic selection of the optimal proton energy for each arc is vital. We present a treatment planning comparison of four different range selection methods, analyzing the dosimetric outcomes of the resulting treatment plans created with the ranges obtained. Given the patient geometry and arc definition (gantry and couch trajectories, snout elevation) our in-house treatment planning system (TPS) FoCa was used to find the maximum, medial and minimum water-equivalent thicknesses (WETs) of the target viewed from all possible field orientations. Optimal ranges were subsequently determined using four methods: (1) by dividing the max/min WET interval into equal steps, (2) by taking the average target midpoints from each field, (3) by taking the average WET of all voxels from all field orientations, and (4) by minimizing the fraction of the target which cannot be reached from any of the available angles. After the range (for mono-energetic plans) or ranges (for bi-energetic plans) were selected, the commercial clinical TPS in use in our institution (Varian Eclipse™) was used to produce the PMAT plans using multifield optimization. Linear energy transfer (LET) distributions of all plans were also calculated using FoCa and compared among the different methods. Mono- and bi-energetic PMAT plans, composed of a single 180° arc, were created for two patient geometries: a C-shaped target located in the mediastinal area of a thoracic tissue-equivalent phantom and a small brain tumor located directly above the brainstem. All plans were optimized using the same procedure to (1) achieve target coverage, (2) reduce dose to OAR and (3) limit dose hot spots in the target. Final outcomes were compared in terms of the resulting dose and LET distributions. Data shows little significant differences among the four studied methods, with superior results obtained with mono-energetic plans. A streamlined systematic method has been implemented in an in-house TPS to find the optimal range to maximize target coverage with rotational mono- or bi-energetic PBS rotational plans by minimizing the fraction of the target that cannot be reached by any direction.
Two-point T1 measurement: wide-coverage optimizations by stochastic simulations.
Lin, M S; Fletcher, J W; Donati, R M
1986-08-01
Stochastic reliability of T1 measurement from image signal ratios is examined in the ideal case by stochastic simulations in the context of wide-coverage optimizations. Precise measurements prove to be accurate, and accurate ones precise. Sign-preserved inversion-recovery (IR)/non-IR techniques are the best ratio method, reciprocal non-IR/IR ones being equivalent, but inconvenient. Wide-coverage optima are relatively unsharp. Suggested guidelines for covering the 150- to 1500-ms T1 band are minimal relevant TE; TI about 400 ms; effective repetition times about in the ratio, TR2(IR)/TR1 (non-IR) = 2.5-3.0, and in a sum as long as possible up to about TR1 + TR2 = 3.5-4.0 s; signal-averaging after and only after TR1 + TR2 has been lengthened to the said region. Also suggested are different guidelines for covering T1 bands, 120-1200 and 200-1800 ms. Typically, precisions and accuracies improve linearly or faster with increasing S/N and (S/N)2, respectively. Unnecessarily high pixel resolutions or thin slicings exact great penalties in accuracies. Progressively shortening TR1 eventually transforms a wide coverage into a sharp targeting with small potential gains in a narrow T1 locality and large compromises almost everywhere else. The simulations yield an insight into applicabilities of standard error propagation analyses in two-point T1 measurement.
Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, Justin, E-mail: justin.roper@emory.edu; Department of Biostatistics and Bioinformatics, Winship Cancer Institute of Emory University, Atlanta, Georgia; Chanyavanich, Vorakarn
2015-11-01
Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was relatedmore » to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values <95%. Coverage worsened substantially when the rotational error increased to 2.0°: D95 and V95 values were >95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.« less
A Max-Flow Based Algorithm for Connected Target Coverage with Probabilistic Sensors
Shan, Anxing; Xu, Xianghua; Cheng, Zongmao; Wang, Wensheng
2017-01-01
Coverage is a fundamental issue in the research field of wireless sensor networks (WSNs). Connected target coverage discusses the sensor placement to guarantee the needs of both coverage and connectivity. Existing works largely leverage on the Boolean disk model, which is only a coarse approximation to the practical sensing model. In this paper, we focus on the connected target coverage issue based on the probabilistic sensing model, which can characterize the quality of coverage more accurately. In the probabilistic sensing model, sensors are only be able to detect a target with certain probability. We study the collaborative detection probability of target under multiple sensors. Armed with the analysis of collaborative detection probability, we further formulate the minimum ϵ-connected target coverage problem, aiming to minimize the number of sensors satisfying the requirements of both coverage and connectivity. We map it into a flow graph and present an approximation algorithm called the minimum vertices maximum flow algorithm (MVMFA) with provable time complex and approximation ratios. To evaluate our design, we analyze the performance of MVMFA theoretically and also conduct extensive simulation studies to demonstrate the effectiveness of our proposed algorithm. PMID:28587084
A Max-Flow Based Algorithm for Connected Target Coverage with Probabilistic Sensors.
Shan, Anxing; Xu, Xianghua; Cheng, Zongmao; Wang, Wensheng
2017-05-25
Coverage is a fundamental issue in the research field of wireless sensor networks (WSNs). Connected target coverage discusses the sensor placement to guarantee the needs of both coverage and connectivity. Existing works largely leverage on the Boolean disk model, which is only a coarse approximation to the practical sensing model. In this paper, we focus on the connected target coverage issue based on the probabilistic sensing model, which can characterize the quality of coverage more accurately. In the probabilistic sensing model, sensors are only be able to detect a target with certain probability. We study the collaborative detection probability of target under multiple sensors. Armed with the analysis of collaborative detection probability, we further formulate the minimum ϵ -connected target coverage problem, aiming to minimize the number of sensors satisfying the requirements of both coverage and connectivity. We map it into a flow graph and present an approximation algorithm called the minimum vertices maximum flow algorithm (MVMFA) with provable time complex and approximation ratios. To evaluate our design, we analyze the performance of MVMFA theoretically and also conduct extensive simulation studies to demonstrate the effectiveness of our proposed algorithm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leicher, Brian, E-mail: bleicher@wpahs.org; Day, Ellen; Colonias, Athanasios
2014-10-01
To describe a dosimetric method using an anterior dose avoidance structure (ADAS) during the treatment planning process for intensity-modulated radiation therapy (IMRT) for patients with anal canal and rectal carcinomas. A total of 20 patients were planned on the Elekta/CMS XiO treatment planning system, version 4.5.1 (Maryland Heights MO) with a superposition algorithm. For each patient, 2 plans were created: one employing an ADAS (ADAS plan) and the other replanned without an ADAS (non-ADAS plan). The ADAS was defined to occupy the volume between the inguinal nodes and primary target providing a single organ at risk that is completely outsidemore » of the target volume. Each plan used the same beam parameters and was analyzed by comparing target coverage, overall plan dose conformity using a conformity number (CN) equation, bowel dose-volume histograms, and the number of segments, daily treatment duration, and global maximum dose. The ADAS and non-ADAS plans were equivalent in target coverage, mean global maximum dose, and sparing of small bowel in low-dose regions (5, 10, 15, and 20 Gy). The mean difference between the CN value for the non-ADAS plans and ADAS plans was 0.04 ± 0.03 (p < 0.001). The mean difference in the number of segments was 15.7 ± 12.7 (p < 0.001) in favor of ADAS plans. The ADAS plan delivery time was shorter by 2.0 ± 1.5 minutes (p < 0.001) than the non-ADAS one. The ADAS has proven to be a powerful tool when planning rectal and anal canal IMRT cases with critical structures partially contained inside the target volume.« less
Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles
2013-01-01
Recently, volumetric‐modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity‐modulated fixed‐field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs‐at‐risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed‐field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient‐specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single‐arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2‐T3 N0‐N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281–601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four‐field (n=4) or five‐field (n=9) step‐and‐shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose‐volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose, lung V20 and V5, liver V30, and Dmax to the spinal canal prv3mm. Also examined were the total plan monitor units (MUs) and the beam delivery time. Equivalent target coverage was observed with both VMAT single and two‐arc plans. The comparison of VMATI with fixed‐field IMRT demonstrated equivalent target coverage; statistically no significant difference were found in PTV D99 (p=0.47), PTV mean (p=0.12), PTV D95 and PTV V9547.5Gy (95%) (p=0.38). However, Dmax in VMATI plans was significantly lower compared to IMRT (p=0.02). The Van't Riet dose conformation number (CN) was also statistically in favor of VMATI plans (p=0.04). VMATI achieved lower lung V20 (p=0.05), whereas lung V5 (p=0.35) and mean lung dose (p=0.62) were not significantly different. The other OARs, including spinal canal, liver, heart, and kidneys showed no statistically significant differences between the two techniques. Treatment time delivery for VMATI plans was reduced by up to 55% (p=5.8E−10) and MUs reduced by up to 16% (p=0.001). Integral dose was not statistically different between the two planning techniques (p=0.99). There were no statistically significant differences found in dose distribution of the two VMAT techniques (VMATI vs. VMATII) Dose statistics for both VMAT techniques were: PTV D99 (p=0.76), PTV D95 (p=0.95), mean PTV dose (p=0.78), conformation number (CN) (p=0.26), and MUs (p=0.1). However, the treatment delivery time for VMATII increased significantly by two‐fold (p=3.0E−11) compared to VMATI. VMAT‐based treatment planning is safe and deliverable for patients with thoracic esophageal cancer with similar planning goals, when compared to standard IMRT. The key benefit for VMATI was the reduction in treatment delivery time and MUs, and improvement in dose conformality. In our study, we found no significant difference in VMATII over single‐arc VMATI for PTV coverage or OARs doses. However, we observed significant increase in delivery time for VMATII compared to VMATI. PACS number: 87.53.Kn, 87.55.‐x PMID:23652258
Feiring, Berit; Laake, Ida; Molden, Tor; Håberg, Siri E; Nøkleby, Hanne; Seterelv, Siri Schøyen; Magnus, Per; Trogstad, Lill
2016-04-12
Selective immunisation is an alternative to universal vaccination if children at increased risk of disease can be identified. Within the Norwegian Childhood Immunisation Programme, BCG vaccine against tuberculosis and vaccine against hepatitis B virus (HBV) are offered only to children with parents from countries with high burden of the respective disease. We wanted to study whether this selective immunisation policy reaches the targeted groups. The study population was identified through the Norwegian Central Population Registry and consisted of all children born in Norway 2007-2010 and residing in Norway until their second birthday, in total 240,484 children. Information on vaccinations from the Norwegian Immunisation Registry, and on parental country of birth from Statistics Norway, was linked to the population registry by personal identifiers. The coverage of BCG and HBV vaccine was compared with the coverage of vaccines in the universal programme. Among the study population, 16.1% and 15.9% belonged to the target groups for BCG and HBV vaccine, respectively. Among children in the BCG target group the BCG vaccine coverage was lower than the coverage of pertussis and measles vaccine (83.6% vs. 98.6% and 92.3%, respectively). Likewise, the HBV vaccine coverage was lower than the coverage of pertussis and measles vaccine in the HBV target group (90.0% vs. 98.6% and 92.3%, respectively). The coverage of the targeted vaccines was highest among children with parents from South Asia and Sub-Saharan Africa. The coverage of vaccines in the universal programme was similar in targeted and non-targeted groups. Children targeted by selective vaccination had lower coverage of the target vaccines than of vaccines in the universal programme, indicating that selective vaccination is challenging. Improved routines for identifying eligible children and delivering the target vaccines are needed. Universal vaccination of all children with these vaccines could be considered. Copyright © 2016 Elsevier Ltd. All rights reserved.
MO-FG-CAMPUS-TeP2-04: Optimizing for a Specified Target Coverage Probability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fredriksson, A
2016-06-15
Purpose: The purpose of this work is to develop a method for inverse planning of radiation therapy margins. When using this method the user specifies a desired target coverage probability and the system optimizes to meet the demand without any explicit specification of margins to handle setup uncertainty. Methods: The method determines which voxels to include in an optimization function promoting target coverage in order to achieve a specified target coverage probability. Voxels are selected in a way that retains the correlation between them: The target is displaced according to the setup errors and the voxels to include are selectedmore » as the union of the displaced target regions under the x% best scenarios according to some quality measure. The quality measure could depend on the dose to the considered structure alone or could depend on the dose to multiple structures in order to take into account correlation between structures. Results: A target coverage function was applied to the CTV of a prostate case with prescription 78 Gy and compared to conventional planning using a DVH function on the PTV. Planning was performed to achieve 90% probability of CTV coverage. The plan optimized using the coverage probability function had P(D98 > 77.95 Gy) = 0.97 for the CTV. The PTV plan using a constraint on minimum DVH 78 Gy at 90% had P(D98 > 77.95) = 0.44 for the CTV. To match the coverage probability optimization, the DVH volume parameter had to be increased to 97% which resulted in 0.5 Gy higher average dose to the rectum. Conclusion: Optimizing a target coverage probability is an easily used method to find a margin that achieves the desired coverage probability. It can lead to reduced OAR doses at the same coverage probability compared to planning with margins and DVH functions.« less
NASA Astrophysics Data System (ADS)
Moteabbed, M.; Trofimov, A.; Sharp, G. C.; Wang, Y.; Zietman, A. L.; Efstathiou, J. A.; Lu, H.-M.
2017-03-01
Proton therapy of prostate by anterior beams could offer an attractive option for treating patients with hip prosthesis and limiting the high-dose exposure to the rectum. We investigated the impact of setup and anatomy variations on the anterior-oblique (AO) proton plan dose, and strategies to manage these effects via range verification and adaptive delivery. Ten patients treated by bilateral (BL) passive-scattering proton therapy (79.2 Gy in 44 fractions) who underwent weekly verification CT scans were selected. Plans with AO beams were additionally created. To isolate the effect of daily variations, initial AO plans did not include range uncertainty margins. The use of fixed planning margins and adaptive range adjustments to manage these effects was investigated. For each case, the planned dose was recalculated on weekly CTs, and accumulated on the simulation CT using deformable registration to approximate the delivered dose. Planned and accumulated doses were compared for each scenario to quantify dose deviations induced by variations. The possibility of estimating the necessary range adjustments before each treatment was explored by simulating the procedure of a diode-based in vivo range verification technique, which would potentially be used clinically. The average planned rectum, penile bulb and femoral heads mean doses were smaller for initial AO compared to BL plans (by 8.3, 16.1 and 25.9 Gy, respectively). After considering interfractional variations in AO plans, the target coverage was substantially reduced. The maximum reduction of V 79.2/D 95/D mean/EUD for AO (without distal margins) (25.3%/10.7/1.6/4.9 Gy, respectively) was considerably larger than BL plans. The loss of coverage was mainly related to changes in water equivalent path length of the prostate after fiducial-based setup, caused by discrepancies in patient anterior surface and bony-anatomy alignment. Target coverage was recovered partially when using fixed planning margins, and fully when applying adaptive range adjustments. The accumulated organs-at-risk dose for AO beams after range adjustment demonstrated full sparing of femoral heads and superior sparing of penile bulb and rectum compared to the conventional BL cases. Our study indicates that using AO beams makes prostate treatment more susceptible to target underdose induced by interfractional variations. Adaptive range verification/adjustment may facilitate the use of anterior beam approaches, and ensure adequate target coverage in every fraction of the treatment.
42 CFR 457.431 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
...— (1) By an individual who is a member of the American Academy of Actuaries; (2) Using generally accepted actuarial principles and methodologies of the American Academy of Actuaries; (3) Using a... coverage. (c) The actuary who prepares the opinion must select and specify the standardized set and...
Racial and Ethnic Disparities in Services and the Patient Protection and Affordable Care Act
Abdus, Salam; Mistry, Kamila B.
2015-01-01
Objectives. We examined prereform patterns in insurance coverage, access to care, and preventive services use by race/ethnicity in adults targeted by the coverage expansions of the Patient Protection and Affordable Care Act (ACA). Methods. We used pre-ACA household data from the Medical Expenditure Panel Survey to identify groups targeted by the coverage provisions of the Act (Medicaid expansions and subsidized Marketplace coverage). We examined racial/ethnic differences in coverage, access to care, and preventive service use, across and within ACA relevant subgroups from 2005 to 2010. The study took place at the Agency for Healthcare Research and Quality in Rockville, Maryland. Results. Minorities were disproportionately represented among those targeted by the coverage provisions of the ACA. Targeted groups had lower rates of coverage, access to care, and preventive services use, and racial/ethnic disparities were, in some cases, widest within these targeted groups. Conclusions. Our findings highlighted the opportunity of the ACA to not only to improve coverage, access, and use for all racial/ethnic groups, but also to narrow racial/ethnic disparities in these outcomes. Our results might have particular importance for states that are deciding whether to implement the ACA Medicaid expansions. PMID:26447920
Racial and Ethnic Disparities in Services and the Patient Protection and Affordable Care Act.
Abdus, Salam; Mistry, Kamila B; Selden, Thomas M
2015-11-01
We examined prereform patterns in insurance coverage, access to care, and preventive services use by race/ethnicity in adults targeted by the coverage expansions of the Patient Protection and Affordable Care Act (ACA). We used pre-ACA household data from the Medical Expenditure Panel Survey to identify groups targeted by the coverage provisions of the Act (Medicaid expansions and subsidized Marketplace coverage). We examined racial/ethnic differences in coverage, access to care, and preventive service use, across and within ACA relevant subgroups from 2005 to 2010. The study took place at the Agency for Healthcare Research and Quality in Rockville, Maryland. Minorities were disproportionately represented among those targeted by the coverage provisions of the ACA. Targeted groups had lower rates of coverage, access to care, and preventive services use, and racial/ethnic disparities were, in some cases, widest within these targeted groups. Our findings highlighted the opportunity of the ACA to not only to improve coverage, access, and use for all racial/ethnic groups, but also to narrow racial/ethnic disparities in these outcomes. Our results might have particular importance for states that are deciding whether to implement the ACA Medicaid expansions.
Charlson, Fiona J; Steel, Zachary; Degenhardt, Louisa; Chey, Tien; Silove, Derrick; Marnane, Claire; Whiteford, Harvey A
2012-01-01
Mental disorders are likely to be elevated in the Libyan population during the post-conflict period. We estimated cases of severe PTSD and depression and related health service requirements using modelling from existing epidemiological data and current recommended mental health service targets in low and middle income countries (LMIC's). Post-conflict prevalence estimates were derived from models based on a previously conducted systematic review and meta-regression analysis of mental health among populations living in conflict. Political terror ratings and intensity of exposure to traumatic events were used in predictive models. Prevalence of severe cases was applied to chosen populations along with uncertainty ranges. Six populations deemed to be affected by the conflict were chosen for modelling: Misrata (population of 444,812), Benghazi (pop. 674,094), Zintan (pop. 40,000), displaced people within Tripoli/Zlitan (pop. 49,000), displaced people within Misrata (pop. 25,000) and Ras Jdir camps (pop. 3,700). Proposed targets for service coverage, resource utilisation and full-time equivalent staffing for management of severe cases of major depression and post-traumatic stress disorder (PTSD) are based on a published model for LMIC's. Severe PTSD prevalence in populations exposed to a high level of political terror and traumatic events was estimated at 12.4% (95%CI 8.5-16.7) and was 19.8% (95%CI 14.0-26.3) for severe depression. Across all six populations (total population 1,236,600), the conflict could be associated with 123,200 (71,600-182,400) cases of severe PTSD and 228,100 (134,000-344,200) cases of severe depression; 50% of PTSD cases were estimated to co-occur with severe depression. Based upon service coverage targets, approximately 154 full-time equivalent staff would be required to respond to these cases sufficiently which is substantially below the current level of resource estimates for these regions. This is the first attempt to predict the mental health burden and consequent service response needs of such a conflict, and is crucially timed for Libya.
Charlson, Fiona J.; Steel, Zachary; Degenhardt, Louisa; Chey, Tien; Silove, Derrick; Marnane, Claire; Whiteford, Harvey A.
2012-01-01
Background Mental disorders are likely to be elevated in the Libyan population during the post-conflict period. We estimated cases of severe PTSD and depression and related health service requirements using modelling from existing epidemiological data and current recommended mental health service targets in low and middle income countries (LMIC’s). Methods Post-conflict prevalence estimates were derived from models based on a previously conducted systematic review and meta-regression analysis of mental health among populations living in conflict. Political terror ratings and intensity of exposure to traumatic events were used in predictive models. Prevalence of severe cases was applied to chosen populations along with uncertainty ranges. Six populations deemed to be affected by the conflict were chosen for modelling: Misrata (population of 444,812), Benghazi (pop. 674,094), Zintan (pop. 40,000), displaced people within Tripoli/Zlitan (pop. 49,000), displaced people within Misrata (pop. 25,000) and Ras Jdir camps (pop. 3,700). Proposed targets for service coverage, resource utilisation and full-time equivalent staffing for management of severe cases of major depression and post-traumatic stress disorder (PTSD) are based on a published model for LMIC’s. Findings Severe PTSD prevalence in populations exposed to a high level of political terror and traumatic events was estimated at 12.4% (95%CI 8.5–16.7) and was 19.8% (95%CI 14.0–26.3) for severe depression. Across all six populations (total population 1,236,600), the conflict could be associated with 123,200 (71,600–182,400) cases of severe PTSD and 228,100 (134,000–344,200) cases of severe depression; 50% of PTSD cases were estimated to co-occur with severe depression. Based upon service coverage targets, approximately 154 full-time equivalent staff would be required to respond to these cases sufficiently which is substantially below the current level of resource estimates for these regions. Discussion This is the first attempt to predict the mental health burden and consequent service response needs of such a conflict, and is crucially timed for Libya. PMID:22808201
42 CFR 440.340 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Using a standardized population that is representative of the population involved. (5) Applying the same... taking into account any differences in coverage based on the method of delivery or means of cost control... population to be used in paragraphs (b)(3) and (b)(4) of this section. (d) The State must provide sufficient...
42 CFR 440.340 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Using a standardized population that is representative of the population involved. (5) Applying the same... taking into account any differences in coverage based on the method of delivery or means of cost control... population to be used in paragraphs (b)(3) and (b)(4) of this section. (d) The State must provide sufficient...
42 CFR 440.340 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Using a standardized population that is representative of the population involved. (5) Applying the same... taking into account any differences in coverage based on the method of delivery or means of cost control... population to be used in paragraphs (b)(3) and (b)(4) of this section. (d) The State must provide sufficient...
42 CFR 440.340 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Using a standardized population that is representative of the population involved. (5) Applying the same... taking into account any differences in coverage based on the method of delivery or means of cost control... population to be used in paragraphs (b)(3) and (b)(4) of this section. (d) The State must provide sufficient...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lavoie, Caroline; Higgins, Jane; Bissonnette, Jean-Pierre
2012-12-01
Purpose: To compare the relative accuracy of 2 image guided radiation therapy methods using carina vs spine as landmarks and then to identify which landmark is superior relative to tumor coverage. Methods and Materials: For 98 lung patients, 2596 daily image-guidance cone-beam computed tomography scans were analyzed. Tattoos were used for initial patient alignment; then, spine and carina registrations were performed independently. A separate analysis assessed the adequacy of gross tumor volume, internal target volume, and planning target volume coverage on cone-beam computed tomography using the initial, middle, and final fractions of radiation therapy. Coverage was recorded for primary tumormore » (T), nodes (N), and combined target (T+N). Three scenarios were compared: tattoos alignment, spine registration, and carina registration. Results: Spine and carina registrations identified setup errors {>=}5 mm in 35% and 46% of fractions, respectively. The mean vector difference between spine and carina matching had a magnitude of 3.3 mm. Spine and carina improved combined target coverage, compared with tattoos, in 50% and 34% (spine) to 54% and 46% (carina) of the first and final fractions, respectively. Carina matching showed greater combined target coverage in 17% and 23% of fractions for the first and final fractions, respectively; with spine matching, this was only observed in 4% (first) and 6% (final) of fractions. Carina matching provided superior nodes coverage at the end of radiation compared with spine matching (P=.0006), without compromising primary tumor coverage. Conclusion: Frequent patient setup errors occur in locally advanced lung cancer patients. Spine and carina registrations improved combined target coverage throughout the treatment course, but carina matching provided superior combined target coverage.« less
Coverage-based constraints for IMRT optimization
NASA Astrophysics Data System (ADS)
Mescher, H.; Ulrich, S.; Bangert, M.
2017-09-01
Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is possible to account for uncertainties by explicit minimization of objectives that describe worst-case treatment scenarios, the expectation value of the treatment or the coverage probability of the target volumes during treatment planning. In this note we show that approaches relying on objectives to induce a specific coverage of the clinical target volumes are inevitably sensitive to variation of the relative weighting of the objectives. To address this issue, we introduce coverage-based constraints for intensity-modulated radiation therapy (IMRT) treatment planning. Our implementation follows the concept of coverage-optimized planning that considers explicit error scenarios to calculate and optimize patient-specific probabilities q(\\hat{d}, \\hat{v}) of covering a specific target volume fraction \\hat{v} with a certain dose \\hat{d} . Using a constraint-based reformulation of coverage-based objectives we eliminate the trade-off between coverage and competing objectives during treatment planning. In-depth convergence tests including 324 treatment plan optimizations demonstrate the reliability of coverage-based constraints for varying levels of probability, dose and volume. General clinical applicability of coverage-based constraints is demonstrated for two cases. A sensitivity analysis regarding penalty variations within this planing study based on IMRT treatment planning using (1) coverage-based constraints, (2) coverage-based objectives, (3) probabilistic optimization, (4) robust optimization and (5) conventional margins illustrates the potential benefit of coverage-based constraints that do not require tedious adjustment of target volume objectives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Widesott, Lamberto, E-mail: widesott@yahoo.it; Pierelli, Alessio; Fiorino, Claudio
2011-08-01
Purpose: To compare intensity-modulated proton therapy (IMPT) and helical tomotherapy (HT) treatment plans for high-risk prostate cancer (HRPCa) patients. Methods and Materials: The plans of 8 patients with HRPCa treated with HT were compared with IMPT plans with two quasilateral fields set up (-100{sup o}; 100{sup o}) and optimized with the Hyperion treatment planning system. Both techniques were optimized to simultaneously deliver 74.2 Gy/Gy relative biologic effectiveness (RBE) in 28 fractions on planning target volumes (PTVs)3-4 (P + proximal seminal vesicles), 65.5 Gy/Gy(RBE) on PTV2 (distal seminal vesicles and rectum/prostate overlapping), and 51.8 Gy/Gy(RBE) to PTV1 (pelvic lymph nodes). Normalmore » tissue calculation probability (NTCP) calculations were performed for the rectum, and generalized equivalent uniform dose (gEUD) was estimated for the bowel cavity, penile bulb and bladder. Results: A slightly better PTV coverage and homogeneity of target dose distribution with IMPT was found: the percentage of PTV volume receiving {>=}95% of the prescribed dose (V{sub 95%}) was on average >97% in HT and >99% in IMPT. The conformity indexes were significantly lower for protons than for photons, and there was a statistically significant reduction of the IMPT dosimetric parameters, up to 50 Gy/Gy(RBE) for the rectum and bowel and 60 Gy/Gy(RBE) for the bladder. The NTCP values for the rectum were higher in HT for all the sets of parameters, but the gain was small and in only a few cases statistically significant. Conclusions: Comparable PTV coverage was observed. Based on NTCP calculation, IMPT is expected to allow a small reduction in rectal toxicity, and a significant dosimetric gain with IMPT, both in medium-dose and in low-dose range in all OARs, was observed.« less
Friesen, Valerie M; Aaron, Grant J; Myatt, Mark; Neufeld, Lynnette M
2017-05-01
Food fortification is a widely used approach to increase micronutrient intake in the diet. High coverage is essential for achieving impact. Data on coverage is limited in many countries, and tools to assess coverage of fortification programs have not been standardized. In 2013, the Global Alliance for Improved Nutrition developed the Fortification Assessment Coverage Toolkit (FACT) to carry out coverage assessments in both population-based (i.e., staple foods and/or condiments) and targeted (e.g., infant and young child) fortification programs. The toolkit was designed to generate evidence on program coverage and the use of fortified foods to provide timely and programmatically relevant information for decision making. This supplement presents results from FACT surveys that assessed the coverage of population-based and targeted food fortification programs across 14 countries. It then discusses the policy and program implications of the findings for the potential for impact and program improvement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ming, X; Zhang, Y; Yale University, New Haven, CT, US
2014-06-01
Purpose: The cardiac toxicity for lung cancer patients, each treated with dynamic conformal arc therapy (DAT), intensity-modulated radiation therapy (IMRT), or volumetric modulated arc therapy (VMAT) is investigated. Methods: 120 lung patients were selected for this study: 25 treated with DAT, 50 with IMRT and 45 with VMAT. For comparison, all plans were generated in the same treatment planning system, normalized such that the 100% isodose lines encompassed 95% of planning target volume. The plan quality was evaluated in terms of homogeneity index (HI) and 95% conformity index (%95 CI) for target dose coverage and mean dose, maximum dose, V{submore » 30} Gy as well as V{sub 5} Gy for cardiac toxicity analysis. Results: When all the plans were analyzed, the VMAT plans offered the best target coverage with 95% CI = 0.992 and HI = 1.23. The DAT plans provided the best heart sparing with mean heart dose = 2.3Gy and maximum dose = 11.6Gy, as compared to 5.7 Gy and 31.1 Gy by IMRT as well as 4.6 Gy and 30.9 Gy by VMAT. The mean V30Gy and V5Gy of the heart in the DAT plans were up to 11.7% lower in comparison to the IMRT and VMAT plans. When the tumor volume was considered, the VMAT plans spared up to 70.9% more doses to the heart when the equivalent diameter of the tumor was larger than 4cm. Yet the maximum dose to the heart was reduced the most in the DAT plans with up to 139.8% less than that of the other two plans. Conclusion: Overall, the VMAT plans achieved the best target coverage among the three treatment modalities, and would spare the heart the most for the larger tumors. The DAT plans appeared advantageous in delivering the least maximum dose to the heart as compared to the IMRT and VMAT plans.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bossart, Elizabeth L., E-mail: EBossart@med.miami.edu; Stoyanova, Radka; Sandler, Kiri
2016-06-01
Purpose: To compare dosimetric characteristics with multiparametric magnetic resonance imaging–identified imaging tumor volume (gross tumor volume, GTV), prostate clinical target volume and planning target volume, and organs at risk (OARs) for 2 treatment techniques representing 2 arms of an institutional phase 3 randomized trial of hypofractionated external beam image guided highly targeted radiation therapy. Methods and Materials: Group 1 (n=20) patients were treated before the trial inception with the standard dose prescription. Each patient had an additional treatment plan generated per the experimental arm. A total of 40 treatment plans were compared (20 plans for each technique). Group 2 (n=15)more » consists of patients currently accrued to the hypofractionated external beam image guided highly targeted radiation therapy trial. Plans were created as per the treatment arm, with additional plans for 5 of the group 2 experimental arm with a 3-mm expansion in the imaging GTV. Results: For all plans in both patient groups, planning target volume coverage ranged from 95% to 100%; GTV coverage of 89.3 Gy for the experimental treatment plans ranged from 95.2% to 99.8%. For both groups 1 and 2, the percent volumes of rectum/anus and bladder receiving 40 Gy, 65 Gy, and 80 Gy were smaller in the experimental plans than in the standard plans. The percent volume at 1 Gy per fraction and 1.625 Gy per fraction were compared between the standard and the experimental arms, and these were found to be equivalent. Conclusions: The dose per fraction to the OARs can be made equal even when giving a large simultaneous integrated boost to the GTV. The data suggest that a GTV margin may be added without significant dose effects on the OARs.« less
Progress in global measles control, 2000-2010.
2012-02-03
In 1980, before widespread global use of measles vaccine, an estimated 2.6 million measles deaths occurred worldwide. In 2001, to accelerate the reduction in measles cases achieved by vaccination, the World Health Organization (WHO) and the United Nations Children's Fund (UNICEF) developed a strategy to deliver 2 doses of measles-containing vaccine (MCV) to all children through routine services and supplementary immunization activities (SIAs) and improved disease surveillance. After implementation of this strategy, the estimated number of annual measles deaths worldwide decreased from 733,000 in 2000 to 164,000 in 2008. In 2010, the World Health Assembly endorsed the following measles objectives for 2015: 1) raise routine coverage with the first dose of MCV (MCV1) for children aged 1 year to ≥90% nationally and ≥80% in every district or equivalent administrative unit, 2) reduce and maintain annual measles incidence at <5 cases per million, and 3) reduce measles mortality by ≥95% from the 2000 estimate. During 2000-2010, global MCV1 coverage increased from 72% to 85% with approximately 1 billion children vaccinated during measles SIAs. Reported measles cases decreased from 2000 to 2008, remained stable in 2009, and increased in 2010. By the end of 2010, 40% of countries still had not met the incidence target of <5 cases per million. Key challenges must be overcome to meet the 2015 objectives, including 1) declining political and financial commitments to measles control, 2) failure to reach uniform high coverage with 2 doses of MCV through routine services or SIAs, and 3) inadequate monitoring subnationally of coverage with the first and second dose of MCV to guide interventions to increase coverage.
Target Coverage in Wireless Sensor Networks with Probabilistic Sensors
Shan, Anxing; Xu, Xianghua; Cheng, Zongmao
2016-01-01
Sensing coverage is a fundamental problem in wireless sensor networks (WSNs), which has attracted considerable attention. Conventional research on this topic focuses on the 0/1 coverage model, which is only a coarse approximation to the practical sensing model. In this paper, we study the target coverage problem, where the objective is to find the least number of sensor nodes in randomly-deployed WSNs based on the probabilistic sensing model. We analyze the joint detection probability of target with multiple sensors. Based on the theoretical analysis of the detection probability, we formulate the minimum ϵ-detection coverage problem. We prove that the minimum ϵ-detection coverage problem is NP-hard and present an approximation algorithm called the Probabilistic Sensor Coverage Algorithm (PSCA) with provable approximation ratios. To evaluate our design, we analyze the performance of PSCA theoretically and also perform extensive simulations to demonstrate the effectiveness of our proposed algorithm. PMID:27618902
Zha, Haihong; Cai, Yuping; Yin, Yandong; Wang, Zhuozhong; Li, Kang; Zhu, Zheng-Jiang
2018-03-20
The complexity of metabolome presents a great analytical challenge for quantitative metabolite profiling, and restricts the application of metabolomics in biomarker discovery. Targeted metabolomics using multiple-reaction monitoring (MRM) technique has excellent capability for quantitative analysis, but suffers from the limited metabolite coverage. To address this challenge, we developed a new strategy, namely, SWATHtoMRM, which utilizes the broad coverage of SWATH-MS technology to develop high-coverage targeted metabolomics method. Specifically, SWATH-MS technique was first utilized to untargeted profile one pooled biological sample and to acquire the MS 2 spectra for all metabolites. Then, SWATHtoMRM was used to extract the large-scale MRM transitions for targeted analysis with coverage as high as 1000-2000 metabolites. Then, we demonstrated the advantages of SWATHtoMRM method in quantitative analysis such as coverage, reproducibility, sensitivity, and dynamic range. Finally, we applied our SWATHtoMRM approach to discover potential metabolite biomarkers for colorectal cancer (CRC) diagnosis. A high-coverage targeted metabolomics method with 1303 metabolites in one injection was developed to profile colorectal cancer tissues from CRC patients. A total of 20 potential metabolite biomarkers were discovered and validated for CRC diagnosis. In plasma samples from CRC patients, 17 out of 20 potential biomarkers were further validated to be associated with tumor resection, which may have a great potential in assessing the prognosis of CRC patients after tumor resection. Together, the SWATHtoMRM strategy provides a new way to develop high-coverage targeted metabolomics method, and facilitates the application of targeted metabolomics in disease biomarker discovery. The SWATHtoMRM program is freely available on the Internet ( http://www.zhulab.cn/software.php ).
Optimization of Self-Directed Target Coverage in Wireless Multimedia Sensor Network
Yang, Yang; Wang, Yufei; Pi, Dechang; Wang, Ruchuan
2014-01-01
Video and image sensors in wireless multimedia sensor networks (WMSNs) have directed view and limited sensing angle. So the methods to solve target coverage problem for traditional sensor networks, which use circle sensing model, are not suitable for WMSNs. Based on the FoV (field of view) sensing model and FoV disk model proposed, how expected multimedia sensor covers the target is defined by the deflection angle between target and the sensor's current orientation and the distance between target and the sensor. Then target coverage optimization algorithms based on expected coverage value are presented for single-sensor single-target, multisensor single-target, and single-sensor multitargets problems distinguishingly. Selecting the orientation that sensor rotated to cover every target falling in the FoV disk of that sensor for candidate orientations and using genetic algorithm to multisensor multitargets problem, which has NP-complete complexity, then result in the approximated minimum subset of sensors which covers all the targets in networks. Simulation results show the algorithm's performance and the effect of number of targets on the resulting subset. PMID:25136667
Kishan, Amar U; Cao, Minsong; Mikaeilian, Argin G; Low, Daniel A; Kupelian, Patrick A; Steinberg, Michael L; Kamrava, Mitchell
2015-01-01
The purpose of this study was to investigate the dosimetric differences of delivering preoperative intensity modulated radiation therapy (IMRT) to patients with soft tissue sarcomas of the extremity (ESTS) with a teletherapy system equipped with 3 rotating (60)Co sources and a built-in magnetic resonance imaging and with standard linear accelerator (LINAC)-based IMRT. The primary study population consisted of 9 patients treated with preoperative radiation for ESTS between 2008 and 2014 with LINAC-based static field IMRT. LINAC plans were designed to deliver 50 Gy in 25 fractions to 95% of the planning target volume (PTV). Tri-(60)Co system IMRT plans were designed with ViewRay system software. Tri-(60)Co-based IMRT plans achieved equivalent target coverage and dosimetry for organs at risk (long bone, skin, and skin corridor) compared with LINAC-based IMRT plans. The maximum and minimum PTV doses, heterogeneity indices, and ratio of the dose to 50% of the volume were equivalent for both planning systems. One LINAC plan violated the maximum bone dose constraint, whereas none of the tri-(60)Co plans did. Using a tri-(60)Co system, we were able to achieve equivalent dosimetry to the PTV and organs at risk for patients with ESTS compared with LINAC-based IMRT plans. The tri-(60)Co system may be advantageous over current treatment platforms by allowing PTV reduction and by elimination of the additional radiation dose associated with daily image guidance, but this needs to be evaluated prospectively. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Limiting diffusion current at rotating disk electrode with dense particle layer.
Weroński, P; Nosek, M; Batys, P
2013-09-28
Exploiting the concept of diffusion permeability of multilayer gel membrane and porous multilayer we have derived a simple analytical equation for the limiting diffusion current at rotating disk electrode (RDE) covered by a thin layer with variable tortuosity and porosity, under the assumption of negligible convection in the porous film. The variation of limiting diffusion current with the porosity and tortuosity of the film can be described in terms of the equivalent thickness of stagnant solution layer, i.e., the average ratio of squared tortuosity to porosity. In case of monolayer of monodisperse spherical particles, the equivalent layer thickness is an algebraic function of the surface coverage. Thus, by means of cyclic voltammetry of RDE with a deposited particle monolayer we can determine the monolayer surface coverage. The effect of particle layer adsorbed on the surface of RDE increases non-linearly with surface coverage. We have tested our theoretical results experimentally by means of cyclic voltammetry measurements of limiting diffusion current at the glassy carbon RDE covered with a monolayer of 3 μm silica particles. The theoretical and experimental results are in a good agreement at the surface coverage higher than 0.7. This result suggests that convection in a monolayer of 3 μm monodisperse spherical particles is negligibly small, in the context of the coverage determination, in the range of very dense particle layers.
Neal, Sarah; Channon, Andrew Amos; Carter, Sarah; Falkingham, Jane
2015-06-16
The drive toward universal health coverage (UHC) is central to the post 2015 agenda, and is incorporated as a target in the new Sustainable Development Goals. However, it is recognised that an equity dimension needs to be included when progress to this goal is monitored. WHO have developed a monitoring framework which proposes a target of 80% coverage for all populations regardless of income and place of residence by 2030, and this paper examines the feasibility of this target in relation to antenatal care and skilled care at delivery. We analyse the coverage gap between the poorest and richest groups within the population for antenatal care and presence of a skilled attendant at birth for countries grouped by overall coverage of each maternal health service. Average annual rates of improvement needed for each grouping (disaggregated by wealth quintile and urban/rural residence) to reach the goal are also calculated, alongside rates of progress over the past decades for comparative purposes. Marked inequities are seen in all groups except in countries where overall coverage is high. As the monitoring framework has an absolute target countries with currently very low coverage are required to make rapid and sustained progress, in particular for the poorest and those living in rural areas. The rate of past progress will need to be accelerated markedly in most countries if the target is to be achieved, although several countries have demonstrated the rate of progress required is feasible both for the population as a whole and for the poorest. For countries with currently low coverage the target of 80% essential coverage for all populations will be challenging. Lessons should be drawn from countries who have achieved rapid and equitable progress in the past.
A Two-Phase Coverage-Enhancing Algorithm for Hybrid Wireless Sensor Networks.
Zhang, Qingguo; Fok, Mable P
2017-01-09
Providing field coverage is a key task in many sensor network applications. In certain scenarios, the sensor field may have coverage holes due to random initial deployment of sensors; thus, the desired level of coverage cannot be achieved. A hybrid wireless sensor network is a cost-effective solution to this problem, which is achieved by repositioning a portion of the mobile sensors in the network to meet the network coverage requirement. This paper investigates how to redeploy mobile sensor nodes to improve network coverage in hybrid wireless sensor networks. We propose a two-phase coverage-enhancing algorithm for hybrid wireless sensor networks. In phase one, we use a differential evolution algorithm to compute the candidate's target positions in the mobile sensor nodes that could potentially improve coverage. In the second phase, we use an optimization scheme on the candidate's target positions calculated from phase one to reduce the accumulated potential moving distance of mobile sensors, such that the exact mobile sensor nodes that need to be moved as well as their final target positions can be determined. Experimental results show that the proposed algorithm provided significant improvement in terms of area coverage rate, average moving distance, area coverage-distance rate and the number of moved mobile sensors, when compare with other approaches.
Wieder, Robert; Delarosa, Nila; Bryan, Margarette; Hill, Ann Marie; Amadio, William J
2014-01-01
We tested the hypothesis that prescription coverage affects the prescribing of long-acting opiates to indigent inner city minority patients with cancer pain. We conducted a chart review of 360 patients treated in the Oncology Practice at University of Medicine and Dentistry of New Jersey University Hospital, who were prescribed opiate pain medications. Half the patients were charity care or self-pay (CC/SP), without the benefit of prescription coverage, and half had Medicaid, with unlimited prescription coverage. We evaluated patients discharged from a hospitalization, who had three subsequent outpatient follow-up visits. We compared demographics, pain intensity, the type and dose of opiates, adherence to prescribed pain regimen, unscheduled emergency department visits, and unscheduled hospitalizations. There was a significantly greater use of long-acting opiates in the Medicaid group than in the CC/SP group. The Medicaid group had significantly more African American patients and a greater rate of smoking and substance use, and the CC/SP group disproportionately more Hispanic and Asian patients and less smoking and substance use. Hispanic and Asian patients were less likely to have long-acting opiates prescribed to them. Pain levels and adherence were equivalent in both groups and were not affected by any of these variables except stage of disease, which was equally distributed in the two groups. Appropriate use of long-acting opiates for equivalent levels of cancer pain was influenced only by the availability of prescription coverage. The group without prescription coverage and receiving fewer long-acting opiates had disproportionately more Hispanic and Asian patients. Wiley Periodicals, Inc.
Wieder, Robert; DeLaRosa, Nila; Bryan, Margarette; Hill, Ann Marie; Amadio, William J.
2013-01-01
Purpose We tested the hypothesis that prescription coverage affects the prescribing of long-acting opiates to indigent inner city minority patients with cancer pain. Materials and Methods We conducted a chart review of 360 patients treated in the Oncology Practice at UMDNJ-University Hospital, who were prescribed opiate pain medications. Half the patients were Charity Care or Self Pay (CC/SP), without the benefit of prescription coverage, and half had Medicaid, with unlimited prescription coverage. We evaluated patients discharged from a hospitalization, who had three subsequent outpatient follow up visits. We compared demographics, pain intensity, the type and dose of opiates, adherence to prescribed pain regimen, unscheduled Emergency Department (ED) visits and unscheduled hospitalizations. Results There was a significantly greater use of long-acting opiates in the Medicaid group than in the CC/SP group. The Medicaid group had significantly more African American patients and a greater rate of smoking and substance use and the CC/SP group disproportionately more Hispanic and Asian patients and less smoking and substance use. Hispanic and Asian patients were less likely to have long-acting opiates prescribed to them. Pain levels and adherence were equivalent in both groups and were not affected by any of these variables except stage of disease, which was equally distributed in the two groups. Conclusion Appropriate use of long-acting opiates for equivalent levels of cancer pain are influenced only by the availability of prescription coverage. The group without prescription coverage and receiving fewer long-acting opiates had disproportionately more Hispanic and Asian patients. PMID:24106748
Estimating the coverage of mental health programmes: a systematic review.
De Silva, Mary J; Lee, Lucy; Fuhr, Daniela C; Rathod, Sujit; Chisholm, Dan; Schellenberg, Joanna; Patel, Vikram
2014-04-01
The large treatment gap for people suffering from mental disorders has led to initiatives to scale up mental health services. In order to track progress, estimates of programme coverage, and changes in coverage over time, are needed. Systematic review of mental health programme evaluations that assess coverage, measured either as the proportion of the target population in contact with services (contact coverage) or as the proportion of the target population who receive appropriate and effective care (effective coverage). We performed a search of electronic databases and grey literature up to March 2013 and contacted experts in the field. Methods to estimate the numerator (service utilization) and the denominator (target population) were reviewed to explore methods which could be used in programme evaluations. We identified 15 735 unique records of which only seven met the inclusion criteria. All studies reported contact coverage. No study explicitly measured effective coverage, but it was possible to estimate this for one study. In six studies the numerator of coverage, service utilization, was estimated using routine clinical information, whereas one study used a national community survey. The methods for estimating the denominator, the population in need of services, were more varied and included national prevalence surveys case registers, and estimates from the literature. Very few coverage estimates are available. Coverage could be estimated at low cost by combining routine programme data with population prevalence estimates from national surveys.
Johnson, Perry B; Monterroso, Maria I; Yang, Fei; Mellon, Eric
2017-11-25
This work explores how the choice of prescription isodose line (IDL) affects the dose gradient, target coverage, and treatment time for Gamma Knife radiosurgery when a smaller shot is encompassed within a larger shot at the same stereotactic coordinates (shot within shot technique). Beam profiles for the 4, 8, and 16 mm collimator settings were extracted from the treatment planning system and characterized using Gaussian fits. The characterized data were used to create over 10,000 shot within shot configurations by systematically changing collimator weighting and choice of prescription IDL. Each configuration was quantified in terms of the dose gradient, target coverage, and beam-on time. By analyzing these configurations, it was found that there are regions of overlap in target size where a higher prescription IDL provides equivalent dose fall-off to a plan prescribed at the 50% IDL. Furthermore, the data indicate that treatment times within these regions can be reduced by up to 40%. An optimization strategy was devised to realize these gains. The strategy was tested for seven patients treated for 1-4 brain metastases (20 lesions total). For a single collimator setting, the gradient in the axial plane was steepest when prescribed to the 56-63% (4 mm), 62-70% (8 mm), and 77-84% (16 mm) IDL, respectively. Through utilization of the optimization technique, beam-on time was reduced by more than 15% in 16/20 lesions. The volume of normal brain receiving 12 Gy or above also decreased in many cases, and in only one instance increased by more than 0.5 cm 3 . This work demonstrates that IDL optimization using the shot within shot technique can reduce treatment times without degrading treatment plan quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamilarasu, Suresh; Saminathan, Madeswaran
Purpose: Aim of the current study is to look plan quality, treatment beam ON time for IMRT using 6MV FB (Flatten Beam) and FFFB (Flattening Filter Free Beam) in left breast cancer cases. Methods: Ten left breast cancer patients treated with breast conserving surgical (BCS) procedure approach and adjuvant radiotherapy were selected from the department database. Simultaneous Integrated boost (SIB) technique was used to irradiate the total left breast (PTV) to a dose of 50.40Gy with concomitant enhance to the lumpectomy cavity known as gross tumour volume (GTV) to a dose of 59.40Gy in 28 fractions. Plans 6MV FB IMRTmore » and 6MV FFFB IMRT had been generated to achieve dose to 95% target volume (TV) and spare Organ at risks (OAR’s). Homogeneity index (HI), conformity index (CI), treatment monitor unit (MU),normal tissues integral dose (NTID) and low dose volume of normal tissue were compared. Results: There was no statistically huge difference among the plans with respect to target volume coverage, CI HI, Ipsilateral Lung and Breast. But statistically significant difference (p< 0.05) as observed in Heart, V5Gy of Contralateral Lung, MU’s NTID and low dose volume of normal tissue. Conclusion: 6MV FB and FFF beam produce almost equivalent plans in IMRT modality with admire to target volume coverage, HI, CI. Beam on time and NTID was determined to be much less in 6MV FFFB IMRT. FFF beam leads to a time saving treatment delivery and fewer NTID in cancer of left breast cases.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumaran Nair, C; Hoffman, D; Wright, C
Purpose: We aim to evaluate a new commercial dose mimicking inverse-planning application that was designed to provide cross-platform treatment planning, for its dosimetric quality and efficiency. The clinical benefit of this application allows patients treated on O-shaped linac to receive an equivalent plan on conventional L-shaped linac as needed for workflow or machine downtime. Methods: The dose mimicking optimization process seeks to create a similar DVH of an O-shaped linac-based plans with an alternative treatment technique (IMRT or VMAT), by maintaining target conformity, and penalizing dose falloff outside the target. Ten head and neck (HN) helical delivery plans, including simplemore » and complex cases were selected for re-planning with the dose mimicking application. All plans were generated for a 6 MV beam model, using 7-field/ 9-field IMRT and VMAT techniques. PTV coverage (D1, D99 and homogeneity index [HI]), and OARs avoidance (Dmean / Dmax) were compared. Results: The resulting dose mimicked HN plans achieved acceptable PTV coverage for HI (VMAT 7.0±2.3, 7-fld 7.3±2.4, and 9-fld 7.0±2.4), D99 (98.0%±0.7%, 97.8%±0.7%, and 98.0%±0.7%), as well as D1 (106.4%±2.1%, 106.5%±2.2%, and 106.4%±2.1%), respectively. The OAR dose discrepancy varied: brainstem (2% to 4%), cord (3% to 6%), esophagus (−4% to −8%), larynx (−4% to 2%), and parotid (4% to 14%). Mimicked plans would typically be needed for 1–5 fractions of a treatment course, and we estimate <1% variance would be introduced in target coverage while maintaining comparable low dose to OARs. All mimicked plans were approved by independent physician and passed patient specific QA within our established tolerance. Conclusion: Dose mimicked plans provide a practical alternative for responding to clinical workflow issues, and provide reliability for patient treatment. The quality of dose mimicking for HN patients highly depends on the delivery technique, field numbers and angles, as well as user selection of structures.« less
Wilson, Elizabeth Ruth; Kyle, Theodore K; Nadglowski, Joseph F; Stanford, Fatima Cody
2017-02-01
Evidence-based obesity treatments, such as bariatric surgery, are not considered essential health benefits under the Affordable Care Act. Employer-sponsored wellness programs with incentives based on biometric outcomes are allowed and often used despite mixed evidence regarding their effectiveness. This study examines consumers' perceptions of their coverage for obesity treatments and exposure to workplace wellness programs. A total of 7,378 participants completed an online survey during 2015-2016. Respondents answered questions regarding their health coverage for seven medical services and exposure to employer wellness programs that target weight or body mass index (BMI). Using χ 2 tests, associations between perceptions of exposure to employer wellness programs and coverage for medical services were examined. Differences between survey years were also assessed. Most respondents reported they did not have health coverage for obesity treatments, but more of the respondents with employer wellness programs reported having coverage. Neither the perception of coverage for obesity treatments nor exposure to wellness programs increased between 2015 and 2016. Even when consumers have exposure to employer wellness programs that target BMI, their health insurance often excludes obesity treatments. Given the clinical and cost-effectiveness of such treatments, reducing that coverage gap may mitigate obesity's individual- and population-level effects. © 2017 The Obesity Society.
A Two-Phase Coverage-Enhancing Algorithm for Hybrid Wireless Sensor Networks
Zhang, Qingguo; Fok, Mable P.
2017-01-01
Providing field coverage is a key task in many sensor network applications. In certain scenarios, the sensor field may have coverage holes due to random initial deployment of sensors; thus, the desired level of coverage cannot be achieved. A hybrid wireless sensor network is a cost-effective solution to this problem, which is achieved by repositioning a portion of the mobile sensors in the network to meet the network coverage requirement. This paper investigates how to redeploy mobile sensor nodes to improve network coverage in hybrid wireless sensor networks. We propose a two-phase coverage-enhancing algorithm for hybrid wireless sensor networks. In phase one, we use a differential evolution algorithm to compute the candidate’s target positions in the mobile sensor nodes that could potentially improve coverage. In the second phase, we use an optimization scheme on the candidate’s target positions calculated from phase one to reduce the accumulated potential moving distance of mobile sensors, such that the exact mobile sensor nodes that need to be moved as well as their final target positions can be determined. Experimental results show that the proposed algorithm provided significant improvement in terms of area coverage rate, average moving distance, area coverage–distance rate and the number of moved mobile sensors, when compare with other approaches. PMID:28075365
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 4 2013-10-01 2013-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
Estimating the coverage of mental health programmes: a systematic review
De Silva, Mary J; Lee, Lucy; Fuhr, Daniela C; Rathod, Sujit; Chisholm, Dan; Schellenberg, Joanna; Patel, Vikram
2014-01-01
Background The large treatment gap for people suffering from mental disorders has led to initiatives to scale up mental health services. In order to track progress, estimates of programme coverage, and changes in coverage over time, are needed. Methods Systematic review of mental health programme evaluations that assess coverage, measured either as the proportion of the target population in contact with services (contact coverage) or as the proportion of the target population who receive appropriate and effective care (effective coverage). We performed a search of electronic databases and grey literature up to March 2013 and contacted experts in the field. Methods to estimate the numerator (service utilization) and the denominator (target population) were reviewed to explore methods which could be used in programme evaluations. Results We identified 15 735 unique records of which only seven met the inclusion criteria. All studies reported contact coverage. No study explicitly measured effective coverage, but it was possible to estimate this for one study. In six studies the numerator of coverage, service utilization, was estimated using routine clinical information, whereas one study used a national community survey. The methods for estimating the denominator, the population in need of services, were more varied and included national prevalence surveys case registers, and estimates from the literature. Conclusions Very few coverage estimates are available. Coverage could be estimated at low cost by combining routine programme data with population prevalence estimates from national surveys. PMID:24760874
Measuring populations to improve vaccination coverage
NASA Astrophysics Data System (ADS)
Bharti, Nita; Djibo, Ali; Tatem, Andrew J.; Grenfell, Bryan T.; Ferrari, Matthew J.
2016-10-01
In low-income settings, vaccination campaigns supplement routine immunization but often fail to achieve coverage goals due to uncertainty about target population size and distribution. Accurate, updated estimates of target populations are rare but critical; short-term fluctuations can greatly impact population size and susceptibility. We use satellite imagery to quantify population fluctuations and the coverage achieved by a measles outbreak response vaccination campaign in urban Niger and compare campaign estimates to measurements from a post-campaign survey. Vaccine coverage was overestimated because the campaign underestimated resident numbers and seasonal migration further increased the target population. We combine satellite-derived measurements of fluctuations in population distribution with high-resolution measles case reports to develop a dynamic model that illustrates the potential improvement in vaccination campaign coverage if planners account for predictable population fluctuations. Satellite imagery can improve retrospective estimates of vaccination campaign impact and future campaign planning by synchronizing interventions with predictable population fluxes.
Measuring populations to improve vaccination coverage
Bharti, Nita; Djibo, Ali; Tatem, Andrew J.; Grenfell, Bryan T.; Ferrari, Matthew J.
2016-01-01
In low-income settings, vaccination campaigns supplement routine immunization but often fail to achieve coverage goals due to uncertainty about target population size and distribution. Accurate, updated estimates of target populations are rare but critical; short-term fluctuations can greatly impact population size and susceptibility. We use satellite imagery to quantify population fluctuations and the coverage achieved by a measles outbreak response vaccination campaign in urban Niger and compare campaign estimates to measurements from a post-campaign survey. Vaccine coverage was overestimated because the campaign underestimated resident numbers and seasonal migration further increased the target population. We combine satellite-derived measurements of fluctuations in population distribution with high-resolution measles case reports to develop a dynamic model that illustrates the potential improvement in vaccination campaign coverage if planners account for predictable population fluctuations. Satellite imagery can improve retrospective estimates of vaccination campaign impact and future campaign planning by synchronizing interventions with predictable population fluxes. PMID:27703191
77 FR 31814 - National Flood Insurance Program (NFIP); Insurance Coverage and Rates
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... structures (target repetitive loss buildings) insured under the NFIP. The Notice of Proposed Rulemaking (NPRM) defined target repetitive loss buildings as those with four or more losses, or with two or more flood... flood insurance coverage to a target repetitive loss building, if an owner declined an offer of...
Pezzoli, Lorenzo; Conteh, Ishata; Kamara, Wogba; Gacic-Dobo, Marta; Ronveaux, Olivier; Perea, William A; Lewis, Rosamund F
2012-06-07
In November 2009, Sierra Leone conducted a preventive yellow fever (YF) vaccination campaign targeting individuals aged nine months and older in six health districts. The campaign was integrated with a measles follow-up campaign throughout the country targeting children aged 9-59 months. For both campaigns, the operational objective was to reach 95% of the target population. During the campaign, we used clustered lot quality assurance sampling (C-LQAS) to identify areas of low coverage to recommend timely mop-up actions. We divided the country in 20 non-overlapping lots. Twelve lots were targeted by both vaccinations, while eight only by measles. In each lot, five clusters of ten eligible individuals were selected for each vaccine. The upper threshold (UT) was set at 90% and the lower threshold (LT) at 75%. A lot was rejected for low vaccination coverage if more than 7 unvaccinated individuals (not presenting vaccination card) were found. After the campaign, we plotted the C-LQAS results against the post-campaign coverage estimations to assess if early interventions were successful enough to increase coverage in the lots that were at the level of rejection before the end of the campaign. During the last two days of campaign, based on card-confirmed vaccination status, five lots out of 20 (25.0%) failed for having low measles vaccination coverage and three lots out of 12 (25.0%) for low YF coverage. In one district, estimated post-campaign vaccination coverage for both vaccines was still not significantly above the minimum acceptable level (LT = 75%) even after vaccination mop-up activities. C-LQAS during the vaccination campaign was informative to identify areas requiring mop-up activities to reach the coverage target prior to leaving the region. The only district where mop-up activities seemed to be unsuccessful might have had logistical difficulties that should be further investigated and resolved.
Pezzoli, Lorenzo; Andrews, Nick; Ronveaux, Olivier
2010-05-01
Vaccination programmes targeting disease elimination aim to achieve very high coverage levels (e.g. 95%). We calculated the precision of different clustered lot quality assurance sampling (LQAS) designs in computer-simulated surveys to provide local health officers in the field with preset LQAS plans to simply and rapidly assess programmes with high coverage targets. We calculated sample size (N), decision value (d) and misclassification errors (alpha and beta) of several LQAS plans by running 10 000 simulations. We kept the upper coverage threshold (UT) at 90% or 95% and decreased the lower threshold (LT) progressively by 5%. We measured the proportion of simulations with < or =d individuals unvaccinated or lower if the coverage was set at the UT (pUT) to calculate beta (1-pUT) and the proportion of simulations with >d unvaccinated individuals if the coverage was LT% (pLT) to calculate alpha (1-pLT). We divided N in clusters (between 5 and 10) and recalculated the errors hypothesising that the coverage would vary in the clusters according to a binomial distribution with preset standard deviations of 0.05 and 0.1 from the mean lot coverage. We selected the plans fulfilling these criteria: alpha < or = 5% beta < or = 20% in the unclustered design; alpha < or = 10% beta < or = 25% when the lots were divided in five clusters. When the interval between UT and LT was larger than 10% (e.g. 15%), we were able to select precise LQAS plans dividing the lot in five clusters with N = 50 (5 x 10) and d = 4 to evaluate programmes with 95% coverage target and d = 7 to evaluate programmes with 90% target. These plans will considerably increase the feasibility and the rapidity of conducting the LQAS in the field.
Oldenburg, Catherine E; Amza, Abdou; Kadri, Boubacar; Nassirou, Beido; Cotter, Sun Y; Stoller, Nicole E; West, Sheila K; Bailey, Robin L; Porco, Travis C; Gaynor, Bruce D; Keenan, Jeremy D; Lietman, Thomas M
2018-02-01
Repeated oral azithromycin distribution targeted only to children has proven effective in reducing the ocular Chlamydia that causes trachoma. Here, we assess whether an enhanced coverage target of at least 90% of children is superior to the World Health Organization recommendation of at least 80%. Twenty-four trachoma-endemic communities in Matamèye, Niger, were randomized to a single day of azithromycin distribution aiming for at least 80% coverage or up to 4 days of treatment and > 90% coverage of children under age 12. All distributions were biannual. Children < 5 years of age and adults > 15 years were monitored for ocular Chlamydia infection by polymerase chain reaction every 6 months for 36 months in children and at baseline and 36 months in adults. Ocular Chlamydia prevalence in children decreased from 24.9% (95% confidence interval [CI] 15.9-33.8%) to 4.4% (95% CI 0.6-8.2%, P < 0.001) at 36 months in the standard coverage arm and from 15.6% (95% CI 10.0-21.2%) to 3.3% (95% CI 1.0-5.5%; P < 0.001) in the enhanced coverage arm. Enhanced coverage reduced ocular Chlamydia prevalence in children more quickly over time compared with standard ( P = 0.04). There was no difference between arms at 36 months in children (2.4% lower with enhanced coverage, 95% CI 7.7-12.5%; P = 0.60). No infection was detected in adults at 36 months. Increasing antibiotic coverage among children from 80% to 90% may yield only short term improvements for trachoma control programs. Targeting treatment to children alone may be sufficient for trachoma control in this setting.
Piot, Bram; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal
2010-01-01
Objectives This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. Methods The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. Results A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. Conclusion LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets. PMID:20167732
Piot, Bram; Mukherjee, Amajit; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal
2010-02-01
This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets.
Trosman, Julia R; Weldon, Christine B; Kelley, R Kate; Phillips, Kathryn A
2015-03-01
Next-generation tumor sequencing (NGTS) panels, which include multiple established and novel targets across cancers, are emerging in oncology practice, but lack formal positive coverage by US payers. Lack of coverage may impact access and adoption. This study identified challenges of NGTS coverage by private payers. We conducted semi-structured interviews with 14 NGTS experts on potential NGTS benefits, and with 10 major payers, representing more than 125,000,000 enrollees, on NGTS coverage considerations. We used the framework approach of qualitative research for study design and thematic analyses and simple frequencies to further describe findings. All interviewed payers see potential NGTS benefits, but all noted challenges to formal coverage: 80% state that inherent features of NGTS do not fit the medical necessity definition required for coverage, 70% view NGTS as a bundle of targets versus comprehensive tumor characterization and may evaluate each target individually, and 70% express skepticism regarding new evidence methods proposed for NGTS. Fifty percent of payers expressed sufficient concerns about NGTS adoption and implementation that will preclude their ability to issue positive coverage policies. Payers perceive that NGTS holds significant promise but, in its current form, poses disruptive challenges to coverage policy frameworks. Proactive multidisciplinary efforts to define the direction for NGTS development, evidence generation, and incorporation into coverage policy are necessary to realize its promise and provide patient access. This study contributes to current literature, as possibly the first study to directly interview US payers on NGTS coverage and reimbursement. Copyright © 2015 by the National Comprehensive Cancer Network.
Trosman, Julia R.; Weldon, Christine B.; Kate Kelley, R.; Phillips, Kathryn A.
2015-01-01
Background Next-generation tumor sequencing (NGTS) panels, which include multiple established and novel targets across cancers, are emerging in oncology practice, but lack formal positive coverage by US payers. Lack of coverage may impact access and adoption. This study identified challenges of NGTS coverage by private payers. Methods We conducted semi-structured interviews with 14 NGTS experts on potential NGTS benefits, and with 10 major payers, representing more than 125,000,000 enrollees, on NGTS coverage considerations. We used the framework approach of qualitative research for study design and thematic analyses and simple frequencies to further describe findings. Results All interviewed payers see potential NGTS benefits, but all noted challenges to formal coverage: 80% state that inherent features of NGTS do not fit the medical necessity definition required for coverage, 70% view NGTS as a bundle of targets versus comprehensive tumor characterization and may evaluate each target individually, and 70% express skepticism regarding new evidence methods proposed for NGTS. Fifty percent of payers expressed sufficient concerns about NGTS adoption and implementation that will preclude their ability to issue positive coverage policies. Conclusions Payers perceive that NGTS holds significant promise but, in its current form, poses disruptive challenges to coverage policy frameworks. Proactive multidisciplinary efforts to define the direction for NGTS development, evidence generation, and incorporation into coverage policy are necessary to realize its promise and provide patient access. This study contributes to current literature, as possibly the first study to directly interview US payers on NGTS coverage and reimbursement. PMID:25736008
Nefdt, Rory; Ribaira, Eric; Diallo, Khassoum
2014-10-01
To ensure correct and appropriate funding is available, there is a need to estimate resource needs for improved planning and implementation of integrated Community Case Management (iCCM). To compare and estimate costs for commodity and human resource needs for iCCM, based on treatment coverage rates, bottlenecks and national targets in Ethiopia, Kenya and Zambia from 2014 to 2016. Resource needs were estimated using Ministry of Health (MoH) targets fronm 2014 to 2016 for implementation of case management of pneumonia, diarrhea and malaria through iCCM based on epidemiological, demographic, economic, intervention coverage and other health system parameters. Bottleneck analysis adjusted cost estimates against system barriers. Ethiopia, Kenya and Zambia were chosen to compare differences in iCCM costs in different programmatic implementation landscapes. Coverage treatment rates through iCCM are lowest in Ethiopia, followed by Kenya and Zambia, but Ethiopia had the greatest increases between 2009 and 2012. Deployment of health extension workers (HEWs) in Ethiopia is more advanced compared to Kenya and Zambia, which have fewer equivalent cadres (called commu- nity health workers (CHWs)) covering a smaller proportion of the population. Between 2014 and 2016, the propor- tion of treatments through iCCM compared to health centres are set to increase from 30% to 81% in Ethiopia, 1% to 18% in Kenya and 3% to 22% in Zambia. The total estimated cost of iCCM for these three years are USD 75,531,376 for Ethiopia, USD 19,839,780 for Kenya and USD 33,667,742 for Zambia. Projected per capita expen- diture for 2016 is USD 0.28 for Ethiopia, USD 0.20 in Kenya and USD 0.98 in Zambia. Commodity costs for pneumonia and diarrhea were a small fraction of the total iCCM budget for all three countries (less than 3%), while around 80% of the costs related to human resources. Analysis of coverage, demography and epidemiology data improves estimates of fimding requirements for iCCM. Bottleneck analysis adjusts cost estimates by including system barriers, thus reflecting a more accurate estimate of potential resource utilization. Adding pneumonia and diarrhea interventions to existing large scale community-based malaria case management programs is likely to require relatively small and nationally affordable investments. iCCM can be implemented for USD 0.09 to 0.98 per capita per annum, depending on the stage of scale-up and targets set by the MoH.
Paluska, Petr; Hanus, Josef; Sefrova, Jana; Rouskova, Lucie; Grepl, Jakub; Jansa, Jan; Kasaova, Linda; Hodek, Miroslav; Zouhar, Milan; Vosmik, Milan; Petera, Jiri
2012-01-01
To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.
Latsuzbaia, Ardashel; Arbyn, Marc; Weyers, Steven; Mossong, Joël
2018-04-25
In Luxembourg, a national Human Papillomavirus (HPV) vaccination programme was introduced in 2008, targeting 12-17 year old girls offering a choice of bivalent or quadrivalent vaccine free of charge. In 2015, the programme was changed offering the bivalent vaccine only to 11-13 year old girls. The aim of this study was to evaluate the HPV vaccination coverage, to assess the impact of age target changes and compare vaccination coverage to other European countries. Anonymous HPV vaccination records consisting of individual vaccine doses obtained free of charge in pharmacies between 2008 and 2016 were extracted from the Luxembourgish Social Security database. Additional aggregate tables by nationality and municipality were analysed. Of the target cohort of 39,610 girls born between 1991 and 2003 residing in Luxembourg, 24,550 (62.0%) subjects obtained at least one dose, 22,082 (55.7%) obtained at least two doses, and 17,197 (43.4%) obtained three doses of HPV vaccine. The mean age at first dose was 13.7 years during 2008-14 and 12.7 years in 2016 after the age target change. Coverage varied significantly by nationality (p < 0.0001): Portuguese (80%), former Yugoslavs (74%), Luxembourgish (54%), Belgian (52%), German (47%), French (39%) and other nationalities (51%). Coverage varied also by geographical region, with lower rates (<50%) noted in some Northern and Central areas of Luxembourg (range: 38% to 78%). Overall HPV vaccination coverage in Luxembourg is moderate and varied by nationality and region. The policy changes in 2015 did not have a substantial impact except lowering age at initiating vaccination. Options to improve coverage deserve further investigation. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Target coverage in image-guided stereotactic body radiotherapy of liver tumors.
Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M
2007-05-01
To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.
Constrained motion model of mobile robots and its applications.
Zhang, Fei; Xi, Yugeng; Lin, Zongli; Chen, Weidong
2009-06-01
Target detecting and dynamic coverage are fundamental tasks in mobile robotics and represent two important features of mobile robots: mobility and perceptivity. This paper establishes the constrained motion model and sensor model of a mobile robot to represent these two features and defines the k -step reachable region to describe the states that the robot may reach. We show that the calculation of the k-step reachable region can be reduced from that of 2(k) reachable regions with the fixed motion styles to k + 1 such regions and provide an algorithm for its calculation. Based on the constrained motion model and the k -step reachable region, the problems associated with target detecting and dynamic coverage are formulated and solved. For target detecting, the k-step detectable region is used to describe the area that the robot may detect, and an algorithm for detecting a target and planning the optimal path is proposed. For dynamic coverage, the k-step detected region is used to represent the area that the robot has detected during its motion, and the dynamic-coverage strategy and algorithm are proposed. Simulation results demonstrate the efficiency of the coverage algorithm in both convex and concave environments.
Influenza vaccination coverage among US children from 2004/2005 to 2015/2016.
Tian, Changwei; Wang, Hua; Wang, Wenming; Luo, Xiaoming
2018-05-15
Quantify the influenza vaccine coverage is essential to identify emerging concerns and to immunization programs for targeting interventions. Data from National Health Interview Survey were used to estimate receipt of at least one dose of influenza vaccination among children 6 months to 17 years of age. Influenza vaccination coverage increased from 16.70% during 2004/2005 to 49.43% during 2015/2016 (3.18% per year, P < 0.001); however, the coverage increased slightly after 2010/2011. Children at high risk of influenza complications had higher influenza vaccination coverage than non at-risk children. Boys and girls had similar coverage each year. While the coverage increased from 2004/2005 to 2015/2016 for all age groups, the coverage decreased with age each year (-0.64 to -1.58% per age group). There was a higher and rapid increase of coverage in Northeast than Midwest, South and West. American Indian or Alaskan Native and Asian showed higher coverage than other race groups (White, Black/African American, Multiple race). Multivariable analysis showed that high-risk status and region had the greatest associations with levels of vaccine coverage. Although the influenza vaccination coverage among children had increased remarkably since 2004/2005, establishing more effective immunization programs are warranted to achieve the Healthy People 2020 target.
Iida, Takuya; Takami, Yoshihiro; Yamaguchi, Ryo; Shimazaki, Shuji; Harii, Kiyonori
2005-01-01
Tissue-engineered skin equivalents composed of epidermal and dermal components have been widely investigated for coverage of full-thickness skin defects. We developed a tissue-engineered oral mucosa equivalent based on an acellular allogeneic dermal matrix and investigated its characteristics. We also tried and assessed its preliminary clinical application. Human oral mucosal keratinocytes were separated from a piece of oral mucosa and cultured in a chemically-defined medium. The keratinocytes were seeded on to the acellular allogeneic dermal matrix and cultured. Histologically, the mucosa equivalent had a well-stratified epithelial layer. Immunohistochemical study showed that it was similar to normal oral mucosa. We applied this equivalent in one case with an extensive burn wound. The equivalent was transplanted three weeks after the harvest of the patient's oral mucosa and about 30% of the graft finally survived. We conclude that this new oral mucosa equivalent could become a therapeutic option for the treatment of extensive burns.
2012-01-01
Background In November 2009, Sierra Leone conducted a preventive yellow fever (YF) vaccination campaign targeting individuals aged nine months and older in six health districts. The campaign was integrated with a measles follow-up campaign throughout the country targeting children aged 9–59 months. For both campaigns, the operational objective was to reach 95% of the target population. During the campaign, we used clustered lot quality assurance sampling (C-LQAS) to identify areas of low coverage to recommend timely mop-up actions. Methods We divided the country in 20 non-overlapping lots. Twelve lots were targeted by both vaccinations, while eight only by measles. In each lot, five clusters of ten eligible individuals were selected for each vaccine. The upper threshold (UT) was set at 90% and the lower threshold (LT) at 75%. A lot was rejected for low vaccination coverage if more than 7 unvaccinated individuals (not presenting vaccination card) were found. After the campaign, we plotted the C-LQAS results against the post-campaign coverage estimations to assess if early interventions were successful enough to increase coverage in the lots that were at the level of rejection before the end of the campaign. Results During the last two days of campaign, based on card-confirmed vaccination status, five lots out of 20 (25.0%) failed for having low measles vaccination coverage and three lots out of 12 (25.0%) for low YF coverage. In one district, estimated post-campaign vaccination coverage for both vaccines was still not significantly above the minimum acceptable level (LT = 75%) even after vaccination mop-up activities. Conclusion C-LQAS during the vaccination campaign was informative to identify areas requiring mop-up activities to reach the coverage target prior to leaving the region. The only district where mop-up activities seemed to be unsuccessful might have had logistical difficulties that should be further investigated and resolved. PMID:22676225
42 CFR 440.340 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... individual who is a member of the American Academy of Actuaries (AAA). (2) Using generally accepted actuarial principles and methodologies of the AAA. (3) Using a standardized set of utilization and price factors. (4...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu Huijun; Gordon, J. James; Siebers, Jeffrey V.
2011-02-15
Purpose: A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D{sub v} exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structuresmore » meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Methods: Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals {omega} (e.g., {omega}=1 deg., 2 deg., 5 deg., 10 deg., 20 deg.). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment {omega}{sub eff}. In each direction, the DM was calculated by moving the structure in radial steps of size {delta}(=0.1,0.2,0.5,1 mm) until the specified isodose was crossed. Coverage estimation accuracy {Delta}Q was quantified as a function of the sampling parameters {omega} or {omega}{sub eff} and {delta}. Results: The accuracy of coverage estimates depends on angular and radial DMD sampling parameters {omega} or {omega}{sub eff} and {delta}, as well as the employed sampling technique. Target |{Delta}Q|<1% and OAR |{Delta}Q|<3% can be achieved with sampling parameters {omega} or {omega}{sub eff}=20 deg., {delta}=1 mm. Better accuracy (target |{Delta}Q|<0.5% and OAR |{Delta}Q|<{approx}1%) can be achieved with {omega} or {omega}{sub eff}=10 deg., {delta}=0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Conclusions: Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with {omega} or {omega}{sub eff}=10 deg. and {delta}=0.5 mm should be adequate for planning purposes.« less
Xu, Huijun; Gordon, J James; Siebers, Jeffrey V
2011-02-01
A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D, exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structures meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals w (e.g., w = 1 degree, 2 degrees, 5 degrees, 10 degrees, 20 degrees). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment omega eff. In each direction, the DM was calculated by moving the structure in radial steps of size delta (=0.1, 0.2, 0.5, 1 mm) until the specified isodose was crossed. Coverage estimation accuracy deltaQ was quantified as a function of the sampling parameters omega or omega eff and delta. The accuracy of coverage estimates depends on angular and radial DMD sampling parameters omega or omega eff and delta, as well as the employed sampling technique. Target deltaQ/ < l% and OAR /deltaQ/ < 3% can be achieved with sampling parameters omega or omega eef = 20 degrees, delta =1 mm. Better accuracy (target /deltaQ < 0.5% and OAR /deltaQ < approximately 1%) can be achieved with omega or omega eff = 10 degrees, delta = 0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with omega or omega eff = 10 degrees and delta = 0.5 mm should be adequate for planning purposes.
ERIC Educational Resources Information Center
Moss, Nancy
1990-01-01
As the shrinking pool of applicants forces colleges to adapt new approaches to recruiting, media campaigns are emerging as an effective way to send key messages to target audiences. Media relations can lend credibility (news coverage is considered more credible than advertising); save money; reach targeted areas; and communicate key themes. (MLW)
Cerretelli, Stefania; Poggio, Laura; Gimona, Alessandro; Yakob, Getahun; Boke, Shiferaw; Habte, Mulugeta; Coull, Malcolm; Peressotti, Alessandro; Black, Helaina
2018-07-01
Land degradation is a serious issue especially in dry and developing countries leading to ecosystem services (ESS) degradation due to soil functions' depletion. Reliably mapping land degradation spatial distribution is therefore important for policy decisions. The main objectives of this paper were to infer land degradation through ESS assessment and compare the modelling results obtained using different sets of data. We modelled important physical processes (sediment erosion and nutrient export) and the equivalent ecosystem services (sediment and nutrient retention) to infer land degradation in an area in the Ethiopian Great Rift Valley. To model soil erosion/retention capability, and nitrogen export/retention capability, two datasets were used: a 'global' dataset derived from existing global-coverage data and a hybrid dataset where global data were integrated with data from local surveys. The results showed that ESS assessments can be used to infer land degradation and identify priority areas for interventions. The comparison between the modelling results of the two different input datasets showed that caution is necessary if only global-coverage data are used at a local scale. In remote and data-poor areas, an approach that integrates global data with targeted local sampling campaigns might be a good compromise to use ecosystem services in decision-making. Copyright © 2018. Published by Elsevier B.V.
Snider, James W; Mutaf, Yildirim; Nichols, Elizabeth; Hall, Andrea; Vadnais, Patrick; Regine, William F; Feigenberg, Steven J
2017-01-01
Accelerated partial breast irradiation has caused higher than expected rates of poor cosmesis. At our institution, a novel breast stereotactic radiotherapy device has demonstrated dosimetric distributions similar to those in brachytherapy. This study analyzed comparative dose distributions achieved with the device and intensity-modulated radiation therapy accelerated partial breast irradiation. Nine patients underwent computed tomography simulation in the prone position using device-specific immobilization on an institutional review board-approved protocol. Accelerated partial breast irradiation target volumes (planning target volume_10mm) were created per the National Surgical Adjuvant Breast and Bowel Project B-39 protocol. Additional breast stereotactic radiotherapy volumes using smaller margins (planning target volume_3mm) were created based on improved immobilization. Intensity-modulated radiation therapy and breast stereotactic radiotherapy accelerated partial breast irradiation plans were separately generated for appropriate volumes. Plans were evaluated based on established dosimetric surrogates of poor cosmetic outcomes. Wilcoxon rank sum tests were utilized to contrast volumes of critical structures receiving a percentage of total dose ( Vx). The breast stereotactic radiotherapy device consistently reduced dose to all normal structures with equivalent target coverage. The ipsilateral breast V20-100 was significantly reduced ( P < .05) using planning target volume_10mm, with substantial further reductions when targeting planning target volume_3mm. Doses to the chest wall, ipsilateral lung, and breast skin were also significantly lessened. The breast stereotactic radiotherapy device's uniform dosimetric improvements over intensity-modulated accelerated partial breast irradiation in this series indicate a potential to improve outcomes. Clinical trials investigating this benefit have begun accrual.
Deardorff, Katrina V; Rubin Means, Arianna; Ásbjörnsdóttir, Kristjana H; Walson, Judd
2018-02-01
Community-based public health campaigns, such as those used in mass deworming, vitamin A supplementation and child immunization programs, provide key healthcare interventions to targeted populations at scale. However, these programs often fall short of established coverage targets. The purpose of this systematic review was to evaluate the impact of strategies used to increase treatment coverage in community-based public health campaigns. We systematically searched CAB Direct, Embase, and PubMed archives for studies utilizing specific interventions to increase coverage of community-based distribution of drugs, vaccines, or other public health services. We identified 5,637 articles, from which 79 full texts were evaluated according to pre-defined inclusion and exclusion criteria. Twenty-eight articles met inclusion criteria and data were abstracted regarding strategy-specific changes in coverage from these sources. Strategies used to increase coverage included community-directed treatment (n = 6, pooled percent change in coverage: +26.2%), distributor incentives (n = 2, +25.3%), distribution along kinship networks (n = 1, +24.5%), intensified information, education, and communication activities (n = 8, +21.6%), fixed-point delivery (n = 1, +21.4%), door-to-door delivery (n = 1, +14.0%), integrated service distribution (n = 9, +12.7%), conversion from school- to community-based delivery (n = 3, +11.9%), and management by a non-governmental organization (n = 1, +5.8%). Strategies that target improving community member ownership of distribution appear to have a large impact on increasing treatment coverage. However, all strategies used to increase coverage successfully did so. These results may be useful to National Ministries, programs, and implementing partners in optimizing treatment coverage in community-based public health programs.
2018-01-01
Background Community-based public health campaigns, such as those used in mass deworming, vitamin A supplementation and child immunization programs, provide key healthcare interventions to targeted populations at scale. However, these programs often fall short of established coverage targets. The purpose of this systematic review was to evaluate the impact of strategies used to increase treatment coverage in community-based public health campaigns. Methodology/ principal findings We systematically searched CAB Direct, Embase, and PubMed archives for studies utilizing specific interventions to increase coverage of community-based distribution of drugs, vaccines, or other public health services. We identified 5,637 articles, from which 79 full texts were evaluated according to pre-defined inclusion and exclusion criteria. Twenty-eight articles met inclusion criteria and data were abstracted regarding strategy-specific changes in coverage from these sources. Strategies used to increase coverage included community-directed treatment (n = 6, pooled percent change in coverage: +26.2%), distributor incentives (n = 2, +25.3%), distribution along kinship networks (n = 1, +24.5%), intensified information, education, and communication activities (n = 8, +21.6%), fixed-point delivery (n = 1, +21.4%), door-to-door delivery (n = 1, +14.0%), integrated service distribution (n = 9, +12.7%), conversion from school- to community-based delivery (n = 3, +11.9%), and management by a non-governmental organization (n = 1, +5.8%). Conclusions/significance Strategies that target improving community member ownership of distribution appear to have a large impact on increasing treatment coverage. However, all strategies used to increase coverage successfully did so. These results may be useful to National Ministries, programs, and implementing partners in optimizing treatment coverage in community-based public health programs. PMID:29420534
A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy.
Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik
2012-01-01
Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an "effective overlap volume histogram" the authors derived an "interpolated balanced planning target" intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new approach was quantified. Analysis of the 4D dose distributions from all five patients showed that while achieving tumor coverage comparable to the ITV approach, the new planning target definition resulted in reductions of lung V(10), V(20), and V(30) of 6.3% ± 1.7%, 10.6% ± 3.9%, and 12.9% ± 5.5%, respectively, as well as reductions in mean lung dose, mean dose to the GTV-ring and mean heart dose of 8.8% ± 2.5%, 7.2% ± 2.5%, and 10.6% ± 3.6%, respectively. The authors have developed a simple and systematic approach to generate a 4D-interpolated balanced planning target volume that implicitly incorporates the dynamics of respiratory-organ motion without requiring 4D-dose computation or optimization. Preliminary results based on 4D-CT data of five previously treated lung patients showed that this new planning target approach may improve normal tissue sparing without sacrificing tumor coverage.
To close the childhood immunization gap, we need a richer understanding of parents' decision-making.
Corben, Paul; Leask, Julie
2016-12-01
Vaccination is widely acknowledged as one of the most successful public health interventions globally and in most high-income countries childhood vaccination coverage rates are moderately high. Yet in many instances, immunisation rates remain below aspirational targets and have shown only modest progress toward those targets in recent years, despite concerted efforts to improve uptake. In part, coverage rates reflect individual parents' vaccination attitudes and decisions and, because vaccination decision-making is complex and context-specific, it remains challenging at individual and community levels to assist parents to make positive decisions. Consequently, in the search for opportunities to improve immunisation coverage, there has been a renewed research focus on parents' decision-making. This review provides an overview of the literature surrounding parents' vaccination decision-making, offering suggestions for where efforts to increase vaccination coverage should be targeted and identifying areas for further research.
Hamzeiy, Hamid; Cox, Jürgen
2017-02-01
Computational workflows for mass spectrometry-based shotgun proteomics and untargeted metabolomics share many steps. Despite the similarities, untargeted metabolomics is lagging behind in terms of reliable fully automated quantitative data analysis. We argue that metabolomics will strongly benefit from the adaptation of successful automated proteomics workflows to metabolomics. MaxQuant is a popular platform for proteomics data analysis and is widely considered to be superior in achieving high precursor mass accuracies through advanced nonlinear recalibration, usually leading to five to ten-fold better accuracy in complex LC-MS/MS runs. This translates to a sharp decrease in the number of peptide candidates per measured feature, thereby strongly improving the coverage of identified peptides. We argue that similar strategies can be applied to untargeted metabolomics, leading to equivalent improvements in metabolite identification. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Probabilistic track coverage in cooperative sensor networks.
Ferrari, Silvia; Zhang, Guoxian; Wettergren, Thomas A
2010-12-01
The quality of service of a network performing cooperative track detection is represented by the probability of obtaining multiple elementary detections over time along a target track. Recently, two different lines of research, namely, distributed-search theory and geometric transversals, have been used in the literature for deriving the probability of track detection as a function of random and deterministic sensors' positions, respectively. In this paper, we prove that these two approaches are equivalent under the same problem formulation. Also, we present a new performance function that is derived by extending the geometric-transversal approach to the case of random sensors' positions using Poisson flats. As a result, a unified approach for addressing track detection in both deterministic and probabilistic sensor networks is obtained. The new performance function is validated through numerical simulations and is shown to bring about considerable computational savings for both deterministic and probabilistic sensor networks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boehling, Nicholas S.; Grosshans, David R., E-mail: dgrossha@mdanderson.org; Bluett, Jaques B.
Purpose: Cranial irradiation in pediatric patients is associated with serious long-term adverse effects. We sought to determine whether both three-dimensional conformal proton radiotherapy (3D-PRT) and intensity-modulated proton therapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) decrease integral dose to brain areas known to harbor neuronal stem cells, major blood vessels, and other normal brain structures for pediatric patients with craniopharyngiomas. Methods and Materials: IMRT, forward planned, passive scattering proton, and IMPT plans were generated and optimized for 10 pediatric patients. The dose was 50.4 Gy (or cobalt Gy equivalent) delivered in 28 fractions with the requirement for planning target volume (PTV)more » coverage of 95% or better. Integral dose data were calculated from differential dose-volume histograms. Results: The PTV target coverage was adequate for all modalities. IMRT and IMPT yielded the most conformal plans in comparison to 3D-PRT. Compared with IMRT, 3D-PRT and IMPT plans had a relative reduction of integral dose to the hippocampus (3D-PRT, 20.4; IMPT, 51.3%{sup Asterisk-Operator }), dentate gyrus (27.3, 75.0%{sup Asterisk-Operator }), and subventricular zone (4.5, 57.8%{sup Asterisk-Operator }). Vascular organs at risk also had reduced integral dose with the use of proton therapy (anterior cerebral arteries, 33.3{sup Asterisk-Operator }, 100.0%{sup Asterisk-Operator }; middle cerebral arteries, 25.9%{sup Asterisk-Operator }, 100%{sup Asterisk-Operator }; anterior communicating arteries, 30.8{sup Asterisk-Operator }, 41.7%{sup Asterisk-Operator }; and carotid arteries, 51.5{sup Asterisk-Operator }, 77.6{sup Asterisk-Operator }). Relative reduction of integral dose to the infratentorial brain (190.7{sup Asterisk-Operator }, 109.7%{sup Asterisk-Operator }), supratentorial brain without PTV (9.6, 26.8%{sup Asterisk-Operator }), brainstem (45.6, 22.4%{sup Asterisk-Operator }), and whole brain without PTV (19.4{sup Asterisk-Operator }, 34.4%{sup Asterisk-Operator }) were recorded with the use of proton therapy. ({sup Asterisk-Operator }Differences were significant based on Friedman's test with Bonferroni-Dunn correction, {alpha} = 0.05) Conclusions: The current study found that proton therapy was able to avoid excess integral radiation dose to a variety of normal structures at all dose levels while maintaining equal target coverage. Future studies will examine the clinical benefits of these dosimetric advantages.« less
Mallari, Neil Aldrin D; Collar, Nigel J; McGowan, Philip J K; Marsden, Stuart J
2016-04-01
Aichi Target 11 of the Convention on Biological Diversity urges, inter alia, that nations protect at least 17 % of their land, and that protection is effective and targets areas of importance for biodiversity. Five years before reporting on Aichi targets is due, we assessed the Philippines' current protected area system for biodiversity coverage, appropriateness of management regimes and capacity to deliver protection. Although protected estate already covers 11 % of the Philippines' land area, 64 % of its key biodiversity areas (KBAs) remain unprotected. Few protected areas have appropriate management and governance infrastructures, funding streams, management plans and capacity, and a serious mismatch exists between protected area land zonation regimes and conservation needs of key species. For the Philippines to meet the biodiversity coverage and management effectiveness elements of Aichi Target 11, protected area and KBA boundaries should be aligned, management systems reformed to pursue biodiversity-led targets and effective management capacity created.
Tyler, Madelaine K
2016-01-08
This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5-30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ± 2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ± 15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ± 3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, JY; Hong, DL
Purpose: The purpose of this study is to investigate the patient set-up error and interfraction target coverage in cervical cancer using image-guided adaptive radiotherapy (IGART) with cone-beam computed tomography (CBCT). Methods: Twenty cervical cancer patients undergoing intensity modulated radiotherapy (IMRT) were randomly selected. All patients were matched to the isocenter using laser with the skin markers. Three dimensional CBCT projections were acquired by the Varian Truebeam treatment system. Set-up errors were evaluated by radiation oncologists, after CBCT correction. The clinical target volume (CTV) was delineated on each CBCT, and the planning target volume (PTV) coverage of each CBCT-CTVs was analyzed.more » Results: A total of 152 CBCT scans were acquired from twenty cervical cancer patients, the mean set-up errors in the longitudinal, vertical, and lateral direction were 3.57, 2.74 and 2.5mm respectively, without CBCT corrections. After corrections, these were decreased to 1.83, 1.44 and 0.97mm. For the target coverage, CBCT-CTV coverage without CBCT correction was 94% (143/152), and 98% (149/152) with correction. Conclusion: Use of CBCT verfication to measure patient setup errors could be applied to improve the treatment accuracy. In addition, the set-up error corrections significantly improve the CTV coverage for cervical cancer patients.« less
Levi, Jacob; Pozniak, Anton; Heath, Katherine; Hill, Andrew
2018-04-01
In 2014, UNAIDS and partners set the 90-90-90 targets for the HIV treatment cascade. Multiple social, political and structural factors might influence progress towards these targets. We assessed how close countries and regions are to reaching these targets, and compared cascade outcomes with HIV prevalence, gross domestic product (GDP)/capita, conflict and corruption. Country-level HIV cascade data on diagnosis, ART coverage and viral suppression, from 2010 to 2016 were extracted from national reports, published papers and the www.AIDSinfoOnline database, and analysed. Weighted least-squares regression was used to assess predictors of cascade achievement: region, HIV prevalence, GDP/capita, the 2016 Corruption Perceptions Index (CPI), which is an international ranking system, and the 2016 Global Peace Index (GPI), which ranks all countries based on three main categories: societal safety, militarisation and conflict. Data were available for diagnosis for 84 countries, ART coverage for 137 countries, and viral suppression for 94 countries. Regions with the lowest ART coverage were South-east Asia and Pacific (36%), Eastern Europe and Central Asia (17%), and Middle East and North Africa (13%). Lower HIV prevalence was associated with poorer cascade results. Countries with higher GDP/capita achieved higher ART coverage ( P <0.001). Furthermore, countries with lower levels of peace and higher corruption had lower ART coverage ( P <0.001). Countries with a GPI >2.5 all had ART coverage of <40%. Only one country has reached the UNAIDS 90-90-90 targets. International comparison remains difficult due to heterogeneous data reporting. Difficulty meeting UNAIDS targets is associated with lower GDP/capita, lower HIV prevalence, higher corruption and conflict levels.
Ko, Young Eun; Cho, Byungchul; Kim, Su Ssan; Song, Si Yeol; Choi, Eun Kyung; Ahn, Seung Do; Yi, Byongyong
2016-01-01
Purpose To develop a simplified volumetric modulated arc therapy (VMAT) technique for more accurate dose delivery in thoracic stereotactic body radiation therapy (SBRT). Methods and Materials For each of the 22 lung SBRT cases treated with respiratory-gated VMAT, a dose rate modulated arc therapy (DrMAT) plan was retrospectively generated. A dynamic conformal arc therapy plan with 33 adjoining coplanar arcs was designed and their beam weights were optimized by an inverse planning process. All sub-arc beams were converted into a series of control points with varying MLC segment and dose rates and merged into an arc beam for a DrMAT plan. The plan quality of original VMAT and DrMAT was compared in terms of target coverage, compactness of dose distribution, and dose sparing of organs at risk. To assess the delivery accuracy, the VMAT and DrMAT plans were delivered to a motion phantom programmed with the corresponding patients’ respiratory signal; results were compared using film dosimetry with gamma analysis. Results The plan quality of DrMAT was equivalent to that of VMAT in terms of target coverage, dose compactness, and dose sparing for the normal lung. In dose sparing for other critical organs, DrMAT was less effective than VMAT for the spinal cord, heart, and esophagus while being well within the limits specified by the Radiation Therapy Oncology Group. Delivery accuracy of DrMAT to a moving target was similar to that of VMAT using a gamma criterion of 2%/2mm but was significantly better using a 2%/1mm criterion, implying the superiority of DrMAT over VMAT in SBRT for thoracic/abdominal tumors with respiratory movement. Conclusion We developed a DrMAT technique for SBRT that produces plans of a quality similar to that achieved with VMAT but with better delivery accuracy. This technique is well-suited for small tumors with motion uncertainty. PMID:27333199
Progress toward measles preelimination--African Region, 2011-2012.
Masresha, Balcha G; Kaiser, Reinhard; Eshetu, Messeret; Katsande, Reggis; Luce, Richard; Fall, Amadou; Dosseh, Annick R G A; Naouri, Boubker; Byabamazima, Charles R; Perry, Robert; Dabbagh, Alya J; Strebel, Peter; Kretsinger, Katrina; Goodson, James L; Nshimirimana, Deo
2014-04-04
In 2008, the 46 member states of the World Health Organization (WHO) African Region (AFR) adopted a measles preelimination goal to reach by the end of 2012 with the following targets: 1) >98% reduction in estimated regional measles mortality compared with 2000, 2) annual measles incidence of fewer than five reported cases per million population nationally, 3) >90% national first dose of measles-containing vaccine (MCV1) coverage and >80% MCV1 coverage in all districts, and 4) >95% MCV coverage in all districts by supplementary immunization activities (SIAs). Surveillance performance objectives were to report two or more cases of nonmeasles febrile rash illness per 100,000 population, one or more suspected measles cases investigated with blood specimens in ≥80% of districts, and 100% completeness of surveillance reporting from all districts. This report updates previous reports and describes progress toward the measles preelimination goal during 2011-2012. In 2012, 13 (28%) member states had >90% MCV1 coverage, and three (7%) reported >90% MCV1 coverage nationally and >80% coverage in all districts. During 2011-2012, four (15%) of 27 SIAs with available information met the target of >95% coverage in all districts. In 2012, 16 of 43 (37%) member states met the incidence target of fewer than five cases per million, and 19 of 43 (44%) met both surveillance performance targets. In 2011, the WHO Regional Committee for AFR established a goal to achieve measles elimination by 2020. To achieve this goal, intensified efforts to identify and close population immunity gaps and improve surveillance quality are needed, as well as committed leadership and ownership of the measles elimination activities and mobilization of adequate resources to complement funding from global partners.
Multi-Objective Optimization of Spacecraft Trajectories for Small-Body Coverage Missions
NASA Technical Reports Server (NTRS)
Hinckley, David, Jr.; Englander, Jacob; Hitt, Darren
2017-01-01
Visual coverage of surface elements of a small-body object requires multiple images to be taken that meet many requirements on their viewing angles, illumination angles, times of day, and combinations thereof. Designing trajectories capable of maximizing total possible coverage may not be useful since the image target sequence and the feasibility of said sequence given the rotation-rate limitations of the spacecraft are not taken into account. This work presents a means of optimizing, in a multi-objective manner, surface target sequences that account for such limitations.
Testing Strategies for Model-Based Development
NASA Technical Reports Server (NTRS)
Heimdahl, Mats P. E.; Whalen, Mike; Rajan, Ajitha; Miller, Steven P.
2006-01-01
This report presents an approach for testing artifacts generated in a model-based development process. This approach divides the traditional testing process into two parts: requirements-based testing (validation testing) which determines whether the model implements the high-level requirements and model-based testing (conformance testing) which determines whether the code generated from a model is behaviorally equivalent to the model. The goals of the two processes differ significantly and this report explores suitable testing metrics and automation strategies for each. To support requirements-based testing, we define novel objective requirements coverage metrics similar to existing specification and code coverage metrics. For model-based testing, we briefly describe automation strategies and examine the fault-finding capability of different structural coverage metrics using tests automatically generated from the model.
NASA Technical Reports Server (NTRS)
Skidmore, Trent A.
1994-01-01
The results of several case studies using the Global Positioning System coverage model developed at Ohio University are summarized. Presented are results pertaining to outage area, outage dynamics, and availability. Input parameters to the model include the satellite orbit data, service area of interest, geometry requirements, and horizon and antenna mask angles. It is shown for precision-landing Category 1 requirements that the planned GPS 21 Primary Satellite Constellation produces significant outage area and unavailability. It is also shown that a decrease in the user equivalent range error dramatically decreases outage area and improves the service availability.
SU-E-T-639: Proton Dose Calculation for Irregular Motion Using a Sliding Interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, J; Gueorguiev, G; Grassberger, C
2015-06-15
Purpose: While many techniques exist to evaluate dose to regularly moving lung targets, there are few available to calculate dose at tumor positions not present in the 4DCT. We have previously developed a method that extrapolates an existing dose to a new tumor location. In this abstract, we present a novel technique that accounts for relative anatomical shifts at the chest wall interface. We also utilize this procedure to simulate breathing motion functions on a cohort of eleven patients. Amplitudes exceeding the original range of motion were used to evaluate coverage using several aperture and smearing beam settings. Methods: Themore » water-equivalent depth (WED) technique requires an initial dose and CT image at the corresponding tumor position. Each dose volume was converted from its Cartesian geometry into a beam-specific radiological depth space. The sliding chest wall interface was determined by converting the lung contour into this same space. Any dose proximal to the initial boundary of the warped lung contour was held fixed, while the remaining distal dose was moved in the direction of motion along the interface. Results: V95 coverage was computed for each patient using the updated algorithm. Incorporation of the sliding motion yielded large dose differences, with gamma pass rates as low as 69.7% (3mm, 3%) and V95 coverage differences up to 2.0%. Clinical coverage was maintained for most patients with 5 mm excess simulated breathing motion, and up to 10 mm of excess motion was tolerated for a subset of patients and beam settings. Conclusion: We have established a method to determine the maximum allowable excess breathing motion for a given plan on a patient-by-patient basis. By integrating a sliding chest wall interface into our dose calculation technique, we have analyzed the robustness of breathing patterns that differ during treatment from at the time of 4DCT acquisition.« less
NASA Astrophysics Data System (ADS)
Lee, Suk; Cao, Yuan Jie; Chang, Kyung Hwan; Shim, Jang Bo; Kim, Kwang Hyeon; Lee, Nam Kwon; Park, Young Je; Kim, Chul Yong; Cho, Sam Ju; Lee, Sang Hoon; Min, Chul Kee; Kim, Woo Chul; Cho, Kwang Hwan; Huh, Hyun Do; Lim, Sangwook; Shin, Dongho
2015-07-01
The purpose of this study was to use various dosimetrical indices to determine the best intensitymodulated radiation therapy (IMRT) modality - for treating patients with prostate cancer. Ten patients with prostate cancer were included in this study. IMRT plans were designed to include different modalities, including the linac step and shoot, tomotherapy, RapidArc, and proton systems. Various dosimetrical indices, like the prescription isodose to target volume (PITV) ratio, conformity index (CI), homogeneity index (HI), target coverage index (TCI), modified dose homogeneity index (MHI), conformation number (CN), critical organ scoring index (COSI), and quality factor (QF), were determined to compare the different treatment plans. Biological indices, such as the generalized equivalent uniform dose (gEUD) based the tumor control probability (TCP), and the normal tissue complication probability (NTCP), were also calculated and used to compare the treatment plans. The RapidArc plan attained better PTV coverage, as evidenced by its superior PITV, CI, TCI, MHI, and CN values. Regarding organ at risks (OARs), proton therapy exhibited superior dose sparing for the rectum and the bowel in low dose volumes, whereas the tomotherapy and RapidArc plans achieved better dose sparing in high dose volumes. The QF scores showed no significant difference among these plans (p = 0.701). The average TCPs for prostate tumors in the RapidArc, linac and proton plans were higher than the average TCP for Tomotherapy (98.79%, 98.76%, and 98.75% vs. 98.70%, respectively). Regarding the rectum NTCP, RapidArc showed the most favorable result (0.09%) whereas linac resulted in the best bladder NTCP (0.08%).
Fronstin, Paul
2009-01-01
HEALTH CARE TAX CAP: With health reform a major priority of the new 111th Congress and President Barack Obama, this Issue Briefexamines the administrative and implementation issues that arise from one of the major reform proposals: Capping the exclusion of employment-based health coverage from workers' taxable income. The amount that employers contribute toward workers' health coverage is generally excluded, without limit, from workers' taxable income. In addition, workers whose employers sponsor flexible spending accounts are able to pay out-of-pocket expenses with pretax dollars. Employers can also make available a premium conversion arrangement, which allows workers to pay their share of the premium for employment-based coverage with pretax dollars. In 2005, a presidential advisory board concluded that limiting the amount of tax-preferred health coverage could lower overall private-sector health spending. The panel recommended a cap on the amount of employment-based health coverage individuals can exclude from their income tax, as a way to reduce health spending. In his 2008 "Call to Action" for health care reform, Sen. Max Baucus (D-MT), chairman of the Senate Finance Committee, states that "Congress should explore ways to restructure the current tax incentives to encourage more efficient spending on health and to target our tax dollars more effectively and fairly." While a tax cap on health coverage sounds simple, for many employers, it could be difficult to administer and results would vary by employer based on the type of health benefit plan, the size and demographics of their work force, and even where the workers live. The change would be especially difficult for self-insured employers that do not pay insurance premiums, since they would have to set the "premium equivalent" for each worker. This would not only be costly for employers, depending upon the requirements set out by law, but could also create fairness and tax issues for many affected workers. For self-insured employers, calculating insurance premium costs under a tax cap could be done fairly easily using the COBRA premium. However, whether self-insured employers would be able to use the least costly method to determine the value of coverage would have to be determined by law and/or regulations. THE SEC. 89 EXPERIENCE: Sec. 89 of the Tax Reform Act of 1986, which attempted to make employee benefits more standard and fair, became so controversial that it was repealed by Congress in 1989--in part because the regulations created regulatory burdens that were so complicated and costly as to be unworkable. Similarly, valuation calculations under a health coverage tax cap could become overly burdensome if the lessons from Sec. 89 are not heeded.
Cho, Hyunyi; Hall, Jennifer G.; Kosmoski, Carin; Fox, Rebekah L.; Mastin, Teresa
2008-01-01
The majority of tanning bed users in the U.S. are women. Previous health communication research frequently focused on the risk of skin cancer, but few studies assessed the mediated communication environment that may surround women’s beliefs and behaviors relevant to tanning. A content analysis of articles in eight magazines targeting girls, young women, older women, and women who are interested in fitness during the ten-year period of 1997–2006 was conducted. The amount of coverage of tanning bed use consequences was less than 50% of the coverage of tanning benefits. About 40% of the tanning benefits coverage touted looking healthy. The coverage of prevention methods focused on sunscreen use (55%), while the more important methods (e.g., protective clothing use) were rarely featured. Longitudinally, the coverage of the risk and prevention relevant issues increased between 1997 and 2006. The data indicate that the coverage of tanning benefits also increased during the same period. PMID:20228954
Worrall, Eve; Hill, Jenny; Webster, Jayne; Mortimer, Julia
2005-01-01
Widespread coverage of vulnerable populations with insecticide-treated nets (ITNs) constitutes an important component of the Roll Back Malaria (RBM) strategy to control malaria. The Abuja Targets call for 60% coverage of children under 5 years of age and pregnant women by 2005; but current coverage in Africa is unacceptably low. The RBM 'Strategic Framework for Coordinated National Action in Scaling-up Insecticide-Treated Netting Programmes in Africa' promotes coordinated national action and advocates sustained public provision of targeted subsidies to maximise public health benefits, alongside support and stimulation of the private sector. Several countries have already planned or initiated targeted subsidy schemes either on a pilot scale or on a national scale, and have valuable experience which can inform future interventions. The WHO RBM 'Workshop on mapping models for delivering ITNs through targeted subsidies' held in Zambia in 2003 provided an opportunity to share and document these country experiences. This paper brings together experiences presented at the workshop with other information on experiences of targeting subsidies on ITNs, net treatment kits and retreatment services (ITN products) in order to describe alternative approaches, highlight their similarities and differences, outline lessons learnt, and identify gaps in knowledge. We find that while there is a growing body of knowledge on different approaches to targeting ITN subsidies, there are significant gaps in knowledge in crucial areas. Key questions regarding how best to target, how much it will cost and what outcomes (levels of coverage) to expect remain unanswered. High quality, well-funded monitoring and evaluation of alternative approaches to targeting ITN subsidies is vital to develop a knowledge base so that countries can design and implement effective strategies to target ITN subsidies.
Cordova, J. Scott; Kandula, Shravan; Gurbani, Saumya; Zhong, Jim; Tejani, Mital; Kayode, Oluwatosin; Patel, Kirtesh; Prabhu, Roshan; Schreibmann, Eduard; Crocker, Ian; Holder, Chad A.; Shim, Hyunsuk; Shu, Hui-Kuo
2017-01-01
Due to glioblastoma’s infiltrative nature, an optimal radiation therapy (RT) plan requires targeting infiltration not identified by anatomical magnetic resonance imaging (MRI). Here, high-resolution, whole-brain spectroscopic MRI (sMRI) is used to describe tumor infiltration alongside anatomical MRI and simulate the degree to which it modifies RT target planning. In 11 patients with glioblastoma, data from preRT sMRI scans were processed to give high-resolution, whole-brain metabolite maps normalized by contralateral white matter. Maps depicting choline to N-Acetylaspartate (Cho/NAA) ratios were registered to contrast-enhanced T1-weighted RT planning MRI for each patient. Volumes depicting metabolic abnormalities (1.5−, 1.75−, and 2.0-fold increases in Cho/NAA ratios) were compared with conventional target volumes and contrast-enhancing tumor at recurrence. sMRI-modified RT plans were generated to evaluate target volume coverage and organ-at-risk dose constraints. Conventional clinical target volumes and Cho/NAA abnormalities identified significantly different regions of microscopic infiltration with substantial Cho/NAA abnormalities falling outside of the conventional 60 Gy isodose line (41.1, 22.2, and 12.7 cm3, respectively). Clinical target volumes using Cho/NAA thresholds exhibited significantly higher coverage of contrast enhancement at recurrence on average (92.4%, 90.5%, and 88.6%, respectively) than conventional plans (82.5%). sMRI-based plans targeting tumor infiltration met planning objectives in all cases with no significant change in target coverage. In 2 cases, the sMRI-modified plan exhibited better coverage of contrast-enhancing tumor at recurrence than the original plan. Integration of the high-resolution, whole-brain sMRI into RT planning is feasible, resulting in RT target volumes that can effectively target tumor infiltration while adhering to conventional constraints. PMID:28105468
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yewondwossen, M; Robar, J; Parsons, D
Purpose: During radiotherapy treatment, lung tumors can display substantial respiratory motion. This motion usually necessitates enlarged treatment margins to provide full tumour coverage. Unfortunately, these margins limit the dose that can be prescribed for tumour control and cause complications to normal tissue. Options for real-time methods of direct detection of tumour position, and particularly those that obviate the need for inserted fiducial markers, are limited. We propose a method of tumor tracking without implanted fiducial markers using a novel fast switching-target that toggles between a FFF copper/tungsten therapy mode and a FFF low-Z target mode for imaging. In this workmore » we demonstrate proof-of-concept of this new technology. Methods: The prototype includes two targets: i) a FFF copper/tungsten target equivalent to that in the Varian 2100 EX 6 MV, and ii) a low-Z (carbon) target with a thickness of 110% of continuous slowing down approximation range (CSDA) at 7 MeV. The two targets can be exchanged with a custom made linear slide and motor-driven actuator. The usefulness of the switching-target concept is demonstrated through experimental BEV Planar images acquired with continual treatment and imaging at a user-defined period. Results: The prototype switching-target demonstrates that two recent advances in linac technology (FFF target for therapy and low-Z target) can be combined with synergy. The switching-target approach offers the capacity for rapid switching between treatment and high-contrast imaging modes, allowing intrafractional tracking, as demonstrated in this work with dynamic breathing phantom. By using a single beam-line, the design is streamlined and may obviate the need for an auxiliary imaging system (e.g., kV OBI.) Conclusion: This switching-target approach is a feasible combination of two current advances in linac technology (FFF target for therapy and a FFF low-Z target) allowing new options in on-line IGRT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fattori, G; Klimpki, G; Safai, S
Purpose: We aim to compare the performance of discrete spot- or continuous line scanning combined with rescanning in mitigating residual organ motion during gated proton therapy treatments. Methods: The Quasar respiratory phantom was used to move a 2D scintillation detector on a linear trajectory with sinusoidal motion pattern (sin{sup 4}), 20 mm peak-to-peak amplitude and 5 sec period. Its motion was monitored using a customized solution based on optical tracking technology. We compared spot and line scanning plans for a monoenergetic 150 MeV circular field, 50.4 mm radius at isocenter. Transverse dose distributions at 13 cm depth in PMMA (15.47more » mm water equivalent) were measured to compare three options for motion mitigation: rescanning (10× factor), gating and their combination. The gating window was centered in the trajectory plateau to simulate end-exhale gated treatment in presence of 2 mm and 4 mm residual motion, parallel or perpendicular to the primary scanning direction. Results: When the target moves perpendicular to the primary scanning direction, large dose deviations are measured (γ3%/3mm=47%) without mitigation techniques. Beam gating combined with rescanning restores target coverage (γ3%/3mm=91%). For parallel target motion, observed dose distortions in the non-compensated irradiation are smaller (γ3%/3mm=77%). Beam gating alone recovers the 100% gamma pass-rate at 3%/3mm. Continuous line scanning reduces delivery time by up to 60% with respect to discrete spot scanning in presence of motion mitigation, and improves homogeneity when rescanning is applied (up to 20%, perpendicular motion, 4 mm residual motion). Conclusion: The direction of motion has a large impact on the target dose coverage. Nevertheless, even in the worst case scenario, gating combined with rescanning could mitigate the impact of motion on dose deposition. Moreover, continuous line rescanning improves the robustness against residual motion in the gating window. This study has received funding from the European Community’s Seventh Framework Programme (FP7/2007–2013) under grant agreement n.290605 (PSI-FELLOW/COFUND) and ‘Giuliana and Giorgio Stefanini Foundation’.« less
USDA-ARS?s Scientific Manuscript database
The ultimate goal of a pesticide spraying system is to provide adequate coverage on intended canopies with a minimum amount of spray materials and off-target waste. Better spray coverage requires an understanding of the fate and transport of spray droplets carried by turbulent airflows in orchards. ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guerrero, Mariana; Li, X. Allen; Ma Lijun
2005-07-01
Purpose: Whole-pelvis irradiation (WPI) followed by a boost to the tumor site is the standard of practice for the radiotherapeutic management of locally advanced gynecologic cancers. The boost is frequently administered by use of brachytherapy or, occasionally, external-beam radiotherapy (EBRT) when brachytherapy does not provide sufficient coverage because of the size of the tumor or the geometry of the patient. In this work, we propose using an intensity-modulated radiotherapy (IMRT) simultaneous integrated boost (SIB), which is a single-phase process, to replace the conventional two-phase process involving WPI plus a boost. Radiobiological modeling is used to design appropriate regimens for themore » IMRT SIB. To demonstrate feasibility, a dosimetric study is carried out on an example patient. Methods and Materials: The standard linear-quadratic (LQ) model is used to calculate the biologically effective dose (BED) and equivalent uniform dose (EUD). A series of regimens that are biologically equivalent to those conventional two-phase treatments is calculated for the proposed SIB. A commercial inverse planning system (Corvus) was used to generate IMRT SIB plans for a sample patient case that used the newly designed fractionations. The dose-volume histogram (DVH) and EUD of both the target and normal structures for conventional treatments and the SIB are compared. A sparing factor was introduced to characterize the sparing of normal structures. Results: Fractionation regimes that are equivalent to the conventional treatments and are suitable for the IMRT SIB are deduced. For example, a SIB plan with 25 x 3.1 Gy (77.5 Gy) to a tumor is equivalent to a conventional treatment of EBRT of 45 Gy to the whole pelvis in 25 fractions plus a high-dose rate (HDR) brachytherapy boost with 30 Gy in 5 fractions. The normal tissue BED is found to be lower for the SIB plan than for the whole-pelvis plus HDR scheme when a sparing factor for the critical structures is considered. This finding suggests that the IMRT SIB has a better therapeutic ratio. Three IMRT SIB plans with 25 x 1.8 Gy to the pelvic nodes and 25 x 2.4 Gy (60 Gy), 25 x 2.8 Gy (70 Gy), and 25 x 3.2 Gy (80 Gy) to the tumor site were generated for the example patient case. The target coverage ranged from 94% to 95.5%. The sparing of bladder and rectum is significantly improved with the 60 to 70 Gy SIB treatments, as compared with the conventional treatments. The proposed SIB treatment can reduce the treatment time to 5 weeks. Conclusions: An IMRT simultaneous integrated boost to replace the conventional two-phase treatments (whole pelvic irradiation followed by brachytherapy or EBRT boost) is radiobiologically and dosimetricaly feasible for locally advanced gynecological cancers that may not be amenable to brachytherapy for anatomic or medical reasons. In addition to its shorter treatment time, the proposed IMRT SIB can provide significant sparing to normal structures, which offers potential for dose escalation. Issues such as organ motion and changing anatomy as tumor responds still must be addressed.« less
Goswami, Jyotirup; Patra, Niladri B.; Sarkar, Biplab; Basu, Ayan; Pal, Santanu
2013-01-01
Background and Purpose: Conventional portals, based on bony anatomy, for external beam radiotherapy for cervical cancer have been repeatedly demonstrated as inadequate. Conversely, with image-based conformal radiotherapy, better target coverage may be offset by the greater toxicities and poorer compliance associated with treating larger volumes. This study was meant to dosimetrically compare conformal and conventional radiotherapy. Materials and Methods: Five patients of carcinoma cervix underwent planning CT scan with IV contrast and targets, and organs at risk (OAR) were contoured. Two sets of plans-conventional and conformal were generated for each patient. Field sizes were recorded, and dose volume histograms of both sets of plans were generated and compared on the basis of target coverage and OAR sparing. Results: Target coverage was significantly improved with conformal plans though field sizes required were significantly larger. On the other hand, dose homogeneity was not significantly improved. Doses to the OARs (rectum, urinary bladder, and small bowel) were not significantly different across the 2 arms. Conclusion: Three-dimensional conformal radiotherapy gives significantly better target coverage, which may translate into better local control and survival. On the other hand, it also requires significantly larger field sizes though doses to the OARs are not significantly increased. PMID:24455584
Leyvraz, Magali; Wirth, James P; Woodruff, Bradley A; Sankar, Rajan; Sodani, Prahlad R; Sharma, Narottam D; Aaron, Grant J
2016-01-01
The Integrated Child Development Services (ICDS) in the State of Telangana, India, freely provides a fortified complementary food product, Bal Amrutham, as a take-home ration to children 6-35 months of age. In order to understand the potential for impact of any intervention, it is essential to assess coverage and utilization of the program and to address the barriers to its coverage and utilization. A two-stage, stratified cross-sectional cluster survey was conducted to estimate the coverage and utilization of Bal Amrutham and to identify their barriers and drivers. In randomly selected catchment areas of ICDS centers, children under 36 months of age were randomly selected. A questionnaire, constructed from different validated and standard modules and designed to collect coverage data on nutrition programs, was administered to caregivers. A total of 1,077 children were enrolled in the survey. The coverage of the fortified take-home ration was found to be high among the target population. Nearly all caregivers (93.7%) had heard of Bal Amrutham and 86.8% had already received the product for the target child. Among the children surveyed, 57.2% consumed the product regularly. The ICDS program's services were not found to be a barrier to product coverage. In fact, the ICDS program was found to be widely available, accessible, accepted, and utilized by the population in both urban and rural catchment areas, as well as among poor and non-poor households. However, two barriers to optimal coverage were found: the irregular supply of the product to the beneficiaries and the intra-household sharing of the product. Although sharing was common, the product was estimated to provide the target children with significant proportions of the daily requirements of macro- and micronutrients. Bal Amrutham is widely available, accepted, and consumed among the target population in the catchment areas of ICDS centers. The coverage of the product could be further increased by improving the supply chain.
Arbyn, Marc; Simoens, Cindy; Van Oyen, Herman; Foidart, Jean-Michel; Goffin, Frédéric; Simon, Philippe; Fabri, Valérie
2009-05-01
Cervical cancer screening by surveys overestimate coverage because of selection and reporting biases. The prepared Inter-Mutualistic Agency dataset has about 13 million records from Pap smears, colposcopies, cervical biopsies and surgery, performed in Belgium between 1996 and 2000. Cervical cancer screening coverage was defined as the proportion of the target population (women of 25-64 years) that has had a Pap smear taken within the last 3 years. Proportions and incidence rates were computed using official population data of the corresponding age group, area and calendar year. Cervical cancer screening coverage, in the period 1998-2000, was 59% at national level, for the target age group 25-64 years. Differences were small between the 3 regions. Variation ranged from 39% to 71%. Coverage was 64% for 25-29 year old women, 67% for those aged 30-39 years, 56% for those aged 50-54. The modal screening interval was 1 year. In the 3-year period 1998-2000, 3 million smears were taken from the 2.7 million women in the age group 25-64. Only 1.6 million women of the target group got one or more smears in that period and 1.1 million women had no smears, corresponding to an average of 1.88 smears per woman. Coverage reached only 59%, but the number of smears used was sufficient to cover more than 100% of the target population. Structural reduction of overuse and extension of coverage is warranted.
Todor, Dorin A; Barani, Igor J; Lin, Peck-Sun; Anscher, Mitchell S
2011-09-01
To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Nine plans, using 125I, 103Pd, and 131Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTVi) were delineated along with PTV (prostate+5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTVi were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. The EUBED of PTVi in the setting of primary 125I implant increased 20-66% when 103Pd and 131Cs were used compared with 125I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTVi (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland. Copyright © 2011 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todor, Dorin A., E-mail: dtodor@mcvh-vcu.edu; Barani, Igor J.; Lin, Peck-Sun
2011-09-01
Purpose: To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Methods and Materials: Nine plans, using {sup 125}I, {sup 103}Pd, and {sup 131}Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTV{sub i}) were delineated along with PTV (prostate + 5 mm), rectum, and urethra. Single-isotope implants,more » prescribed to conventional doses, were generated to achieve good PTV coverage. The PTV{sub i} were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. Results: The EUBED of PTV{sub i} in the setting of primary {sup 125}I implant increased 20-66% when {sup 103}Pd and {sup 131}Cs were used compared with {sup 125}I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTV{sub i} (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. Conclusions: This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland.« less
Lee, T-F; Ting, H-M; Chao, P-J; Wang, H-Y; Shieh, C-S; Horng, M-F; Wu, J-M; Yeh, S-A; Cho, M-Y; Huang, E-Y; Huang, Y-J; Chen, H-C; Fang, F-M
2012-01-01
Objective We compared and evaluated the differences between two models for treating bilateral breast cancer (BBC): (i) dose–volume-based intensity-modulated radiation treatment (DV plan), and (ii) dose–volume-based intensity-modulated radiotherapy with generalised equivalent uniform dose-based optimisation (DV-gEUD plan). Methods The quality and performance of the DV plan and DV-gEUD plan using the Pinnacle3® system (Philips, Fitchburg, WI) were evaluated and compared in 10 patients with stage T2–T4 BBC. The plans were delivered on a Varian 21EX linear accelerator (Varian Medical Systems, Milpitas, CA) equipped with a Millennium 120 leaf multileaf collimator (Varian Medical Systems). The parameters analysed included the conformity index, homogeneity index, tumour control probability of the planning target volume (PTV), the volumes V20 Gy and V30 Gy of the organs at risk (OAR, including the heart and lungs), mean dose and the normal tissue complication probability. Results Both plans met the requirements for the coverage of PTV with similar conformity and homogeneity indices. However, the DV-gEUD plan had the advantage of dose sparing for OAR: the mean doses of the heart and lungs, lung V20 Gy, and heart V30 Gy in the DV-gEUD plan were lower than those in the DV plan (p<0.05). Conclusions A better result can be obtained by starting with a DV-generated plan and then improving it by adding gEUD-based improvements to reduce the number of iterations and to improve the optimum dose distribution. Advances to knowledge The DV-gEUD plan provided superior dosimetric results for treating BBC in terms of PTV coverage and OAR sparing than the DV plan, without sacrificing the homogeneity of dose distribution in the PTV. PMID:23091290
Oral Cholera Vaccine Coverage during an Outbreak and Humanitarian Crisis, Iraq, 2015.
Lam, Eugene; Al-Tamimi, Wasan; Russell, Steven Paul; Butt, Muhammad Obaid-Ul Islam; Blanton, Curtis; Musani, Altaf Sadrudin; Date, Kashmira
2017-01-01
During November-December 2015, as part of the 2015 cholera outbreak response in Iraq, the Iraqi Ministry of Health targeted ≈255,000 displaced persons >1 year of age with 2 doses of oral cholera vaccine (OCV). All persons who received vaccines were living in selected refugee camps, internally displaced persons camps, and collective centers. We conducted a multistage cluster survey to obtain OCV coverage estimates in 10 governorates that were targeted during the campaign. In total, 1,226 household and 5,007 individual interviews were conducted. Overall, 2-dose OCV coverage in the targeted camps was 87% (95% CI 85%-89%). Two-dose OCV coverage in the 3 northern governorates (91%; 95% CI 87%-94%) was higher than that in the 7 southern and central governorates (80%; 95% CI 77%-82%). The experience in Iraq demonstrates that OCV campaigns can be successfully implemented as part of a comprehensive response to cholera outbreaks among high-risk populations in conflict settings.
2016-01-01
This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5–30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ±2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ±15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ±3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI. PACS numbers: 87.55.km, 87.56.Fc PMID:26894347
Formal methods for test case generation
NASA Technical Reports Server (NTRS)
Rushby, John (Inventor); De Moura, Leonardo Mendonga (Inventor); Hamon, Gregoire (Inventor)
2011-01-01
The invention relates to the use of model checkers to generate efficient test sets for hardware and software systems. The method provides for extending existing tests to reach new coverage targets; searching *to* some or all of the uncovered targets in parallel; searching in parallel *from* some or all of the states reached in previous tests; and slicing the model relative to the current set of coverage targets. The invention provides efficient test case generation and test set formation. Deep regions of the state space can be reached within allotted time and memory. The approach has been applied to use of the model checkers of SRI's SAL system and to model-based designs developed in Stateflow. Stateflow models achieving complete state and transition coverage in a single test case are reported.
Evaluation of target coverage and margins adequacy during CyberKnife Lung Optimized Treatment.
Ricotti, Rosalinda; Seregni, Matteo; Ciardo, Delia; Vigorito, Sabrina; Rondi, Elena; Piperno, Gaia; Ferrari, Annamaria; Zerella, Maria Alessia; Arculeo, Simona; Francia, Claudia Maria; Sibio, Daniela; Cattani, Federica; De Marinis, Filippo; Spaggiari, Lorenzo; Orecchia, Roberto; Riboldi, Marco; Baroni, Guido; Jereczek-Fossa, Barbara Alicja
2018-04-01
Evaluation of target coverage and verification of safety margins, in motion management strategies implemented by Lung Optimized Treatment (LOT) module in CyberKnife system. Three fiducial-less motion management strategies provided by LOT can be selected according to tumor visibility in the X ray images acquired during treatment. In 2-view modality the tumor is visible in both X ray images and full motion tracking is performed. In 1-view modality the tumor is visible in a single X ray image, therefore, motion tracking is combined with an internal target volume (ITV)-based margin expansion. In 0-view modality the lesion is not visible, consequently the treatment relies entirely on an ITV-based approach. Data from 30 patients treated in 2-view modality were selected providing information on the three-dimensional tumor motion in correspondence to each X ray image. Treatments in 1-view and 0-view modalities were simulated by processing log files and planning volumes. Planning target volume (PTV) margins were defined according to the tracking modality: end-exhale clinical target volume (CTV) + 3 mm in 2-view and ITV + 5 mm in 0-view. In the 1-view scenario, the ITV encompasses only tumor motion along the non-visible direction. Then, non-uniform ITV to PTV margins were applied: 3 mm and 5 mm in the visible and non-visible direction, respectively. We defined the coverage of each voxel of the CTV as the percentage of X ray images where such voxel was included in the PTV. In 2-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the predicted target position, as recorded in log files. In 1-view modality, coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the projected predictor data. In 0-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the non-moving PTV. Similar to dose-volume histogram, CTV coverage-volume histograms (defined as CVH) were derived for each patient and treatment modality. The geometric coverages of the 90% and 95% of CTV volume (C90, C95, respectively) were evaluated. Patient-specific optimal margins (ensuring C95 ≥ 95%) were computed retrospectively. The median ± interquartile-rage of C90 and C95 for upper lobe lesions was 99.1 ± 0.6% and 99.0 ± 3.1%, whereas they were 98.9 ± 4.2% and 97.8 ± 7.5% for lower and middle lobe tumors. In 2-view, 1-view and 0-view modality, adopted margins ensured C95 ≥ 95% in 70%, 85% and 63% of cases and C95 ≥ 90% in 90%, 88% and 83% of cases, respectively. In 2-view, 1-view and 0-view a reduction in margins still ensured C95 ≥ 95% in 33%, 78% and 59% of cases, respectively. CTV coverage analysis provided an a-posteriori evaluation of the treatment geometric accuracy and allowed a quantitative verification of the adequacy of the PTV margins applied in CyberKnife LOT treatments offering guidance in the selection of CTV margins. © 2018 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Long, Ying; Wood, Troy D.
2015-01-01
Most enzymatic microreactors for protein digestion are based on trypsin, but proteins with hydrophobic segments may be difficult to digest because of the paucity of Arg and Lys residues. Microreactors based on pepsin, which is less specific than trypsin, can overcome this challenge. Here, an integrated immobilized pepsin microreactor (IPMR)/nanoelectrospray emitter is examined for its potential for peptide mapping. For myoglobin, equivalent sequence coverage is obtained in a thousandth the time of solution digestion with better sequence coverage. While sequence coverage of cytochrome c is lesser than solution in this short duration, more highly-charged peptic peptides are produced and a number of peaks are unidentified at low-resolution, suggesting that high-resolution mass spectrometry is needed to take full advantage of integrated IPMR/nanoelectrospray devices.
Shared responsibility for employers regarding health coverage. Final regulations.
2014-02-12
This document contains final regulations providing guidance to employers that are subject to the shared responsibility provisions regarding employee health coverage under section 4980H of the Internal Revenue Code (Code), enacted by the Affordable Care Act. These regulations affect employers referred to as applicable large employers (generally meaning, for each year, employers that had 50 or more full-time employees, including full-time equivalent employees, during the prior year). Generally, under section 4980H an applicable large employer that, for a calendar month, fails to offer to its full-time employees health coverage that is affordable and provides minimum value may be subject to an assessable payment if a full-time employee enrolls for that month in a qualified health plan for which the employee receives a premium tax credit.
42 CFR 440.347 - Essential health benefits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 4 2013-10-01 2013-10-01 false Essential health benefits. 440.347 Section 440.347 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-Equivalent Coverage § 440.347 Essential health benefits. (a) Alternative Benefit Plans must contain essential...
42 CFR 440.347 - Essential health benefits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Essential health benefits. 440.347 Section 440.347 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-Equivalent Coverage § 440.347 Essential health benefits. (a) Alternative Benefit Plans must contain essential...
42 CFR 440.315 - Exempt individuals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Exempt individuals. 440.315 Section 440.315 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS SERVICES: GENERAL PROVISIONS Benchmark Benefit and Benchmark-Equivalent Coverage § 440.315 Exempt individuals....
42 CFR 440.315 - Exempt individuals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Exempt individuals. 440.315 Section 440.315 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS SERVICES: GENERAL PROVISIONS Benchmark Benefit and Benchmark-Equivalent Coverage § 440.315 Exempt individuals....
42 CFR 440.315 - Exempt individuals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Exempt individuals. 440.315 Section 440.315 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS SERVICES: GENERAL PROVISIONS Benchmark Benefit and Benchmark-Equivalent Coverage § 440.315 Exempt individuals....
42 CFR 440.315 - Exempt individuals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 4 2013-10-01 2013-10-01 false Exempt individuals. 440.315 Section 440.315 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS SERVICES: GENERAL PROVISIONS Benchmark Benefit and Benchmark-Equivalent Coverage § 440.315 Exempt individuals....
42 CFR 440.315 - Exempt individuals.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Exempt individuals. 440.315 Section 440.315 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS SERVICES: GENERAL PROVISIONS Benchmark Benefit and Benchmark-Equivalent Coverage § 440.315 Exempt individuals....
34 CFR 200.4 - State law exception.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Academic assessments meet the requirements in § 200.2, particularly regarding validity and reliability... equivalent to one another in their content coverage, difficulty, and quality; (B) Have comparable validity and reliability with respect to groups of students described in section 1111(b)(2)(C)(v) of the Act...
Characterization of a Planet: Dependence on Coverage Fraction
NASA Astrophysics Data System (ADS)
Lorenz, R. D.
1996-03-01
I investigate, by means of numerical experiments and a real-time quiz of colleagues (to be repeated at the poster presentation associated with this abstract), how well-characterized a planet may be considered, as a function of how much of its surface has been studied. Most measures seem to indicate that characterization quality increases steeply up to about 30% coverage. Beyond 30%, additional coverage has a lower marginal value as a 'complete' knowledge of the surface is asymptotically reached. These studies are pertinent where tradeoffs of coverage against other scientific objectives exist, for example the orbital tour design of the Cassini mission. The tour design affects how much of Titan's surface (after the Galileo mission, Titan's surface becomes the largest mappable, but unmapped, area in the solar system) may be covered by the Cassini radar. The mission has too few flybys to cover all of Titan's surface: the Radar team aims to have 30% coverage at 1km resolution or better. I also find that long, thin swaths sample a planet better than square blocks of equivalent area.
Rahman, Md Shafiur; Rahman, Md Mizanur; Gilmour, Stuart; Swe, Khin Thet; Krull Abe, Sarah; Shibuya, Kenji
2018-01-01
Many countries are implementing health system reforms to achieve universal health coverage (UHC) by 2030. To understand the progress towards UHC in Bangladesh, we estimated trends in indicators of the health service and of financial risk protection. We also estimated the probability of Bangladesh's achieving of UHC targets of 80% essential health-service coverage and 100% financial risk protection by 2030. We estimated the coverage of UHC indicators-13 prevention indicators and four treatment indicators-from 19 nationally representative population-based household surveys done in Bangladesh from Jan 1, 1991, to Dec 31, 2014. We used a Bayesian regression model to estimate the trend and to predict the coverage of UHC indicators along with the probabilities of achieving UHC targets of 80% coverage of health services and 100% coverage of financial risk protection from catastrophic and impoverishing health payments by 2030. We used the concentration index and relative index of inequality to assess wealth-based inequality in UHC indicators. If the current trends remain unchanged, we estimated that coverage of childhood vaccinations, improved water, oral rehydration treatment, satisfaction with family planning, and non-use of tobacco will achieve the 80% target by 2030. However, coverage of four antenatal care visits, facility-based delivery, skilled birth attendance, postnatal checkups, care seeking for pneumonia, exclusive breastfeeding, non-overweight, and adequate sanitation were not projected to achieve the target. Quintile-specific projections showed wide wealth-based inequality in access to antenatal care, postnatal care, delivery care, adequate sanitation, and care seeking for pneumonia, and this inequality was projected to continue for all indicators. The incidence of catastrophic health expenditure and impoverishment were projected to increase from 17% and 4%, respectively, in 2015, to 20% and 9%, respectively, by 2030. Inequality analysis suggested that wealthiest households would disproportionately face more financial catastrophe than the most disadvantaged households. Despite progress, Bangladesh will not achieve the 2030 UHC targets unless the country scales up interventions related to maternal and child health services, and reforms health financing systems to avoid high dependency on out-of-pocket payments. The introduction of a national health insurance system, increased public funding for health care, and expansion of community-based clinics in rural areas could help to move the country towards UHC. Japan Ministry of Health, Labour, and Welfare. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY-NC-ND 4.0 license. Published by Elsevier Ltd.. All rights reserved.
Massat, Nathalie J; Douglas, Elaine; Waller, Jo; Wardle, Jane; Duffy, Stephen W
2015-01-01
Objectives Reducing cancer screening inequalities in England is a major focus of the 2011 Department of Health cancer outcome strategy. Screening coverage requires regular monitoring in order to implement targeted interventions where coverage is low. This study aimed to characterise districts with atypical coverage levels for cervical or breast screening. Design Observational study of district-level coverage in the English Cervical and Breast screening programmes in 2012. Setting England, UK. Participants All English women invited to participate in the cervical (age group 25–49 and 50–64) and breast (age group 50–64) screening programmes. Outcomes Risk adjustment models for coverage were developed based on district-level characteristics. Funnel plots of adjusted coverage were constructed, and atypical districts examined by correlation analysis. Results Variability in coverage was primarily explained by population factors, whereas general practice characteristics had little independent effect. Deprivation and ethnicity other than white, Asian, black or mixed were independently associated with poorer coverage in both screening programmes, with ethnicity having the strongest effect; by comparison, the influence of Asian, black or mixed ethnic minority was limited. Deprivation, ethnicity and urbanisation largely accounted for the lower cervical screening coverage in London. However, for breast screening, being located in London remained a strong negative predictor. A subset of districts was identified as having atypical coverage across programmes. Correlates of deprivation in districts with relatively low adjusted coverage were substantially different from overall correlates of deprivation. Discussion These results inform the continuing drive to reduce avoidable cancer deaths in England, and encourage implementation of targeted interventions in communities residing in districts identified as having atypically low coverage. Sequential implementation to monitor the impact of local interventions would help accrue evidence on ‘what works’. PMID:26209119
Dosimetric comparison of photon and proton treatment techniques for chondrosarcoma of thoracic spine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yadav, Poonam, E-mail: yadav@humonc.wisc.edu; Department of Medical Physics, University of Wisconsin, Madison, WI; University of Wisconsin Riverview Cancer Center, Wisconsin Rapids, WI
2013-10-01
Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy. Retrospectively, the tomotherapy plan was compared with intensity-modulated radiation therapy, dynamic arc photon therapy, and proton therapy. Two primary comparisons were made: (1) comparison of normal tissue sparing with comparable target volume coverage (plan-1), and (2) comparison ofmore » target volume coverage with a constrained maximum dose to the cord center (plan-2). With constrained target volume coverage, proton plans were found to yield lower mean doses for all organs at risk (spinal cord, esophagus, heart, and both lungs). Tomotherapy planning resulted in the lowest mean dose to all organs at risk amongst photon-based methods. For cord dose constrained plans, the static-field intensity-modulated radiation therapy and dynamic arc plans resulted target underdosing in 20% and 12% of planning target volume2 volumes, respectively, whereas both proton and tomotherapy plans provided clinically acceptable target volume coverage with no portion of planning target volume2 receiving less than 90% of the prescribed dose. Tomotherapy plans are comparable to proton plans and produce superior results compared with other photon modalities. This feasibility study suggests that tomotherapy is an attractive alternative to proton radiotherapy for delivering high doses to lesions in the thoracic spine.« less
Cantey, Joseph B; Vora, Niraj; Sunkara, Mridula
2017-09-01
Prolonged or unnecessary antibiotic use is associated with adverse outcomes in infants. Antibiotic stewardship programs (ASPs) aim to prevent these adverse outcomes and optimize antibiotic prescribing. However, data evaluating ASP coverage of nurseries are limited. The objectives of this study were to describe the characteristics of nurseries with and without ASP coverage and to determine perceptions of and barriers to nursery ASP coverage. The 2014 American Hospital Association annual survey was used to randomly select a level III neonatal intensive care unit from all 50 states. A level I and level II nursery from the same city as the level III nursery were then randomly selected. Hospital, nursery, and ASP characteristics were collected. Nursery and ASP providers (pharmacists or infectious disease providers) were interviewed using a semistructured template. Transcribed interviews were analyzed for themes. One hundred forty-six centers responded; 104 (71%) provided nursery ASP coverage. In multivariate analysis, level of nursery, university affiliation, and number of full-time equivalent ASP staff were the main predictors of nursery ASP coverage. Several themes were identified from interviews: unwanted coverage, unnecessary coverage, jurisdiction issues, need for communication, and a focus on outcomes. Most providers had a favorable view of nursery ASP coverage. Larger, higher-acuity nurseries in university-affiliated hospitals are more likely to have ASP coverage. Low ASP staffing and a perceived lack of importance were frequently cited as barriers to nursery coverage. Most nursery ASP coverage is viewed favorably by providers, but nursery providers regard it as less important than ASP providers. © The Author 2016. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
O'Donnell, David; Sperzel, Johannes; Thibault, Bernard; Rinaldi, Christopher A; Pappone, Carlo; Gutleben, Klaus-Jürgen; Leclercq, Christopher; Razavi, Hedi; Ryu, Kyungmoo; Mcspadden, Luke C; Fischer, Avi; Tomassoni, Gery
2017-04-01
The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P < 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Ogbuanu, Ikechukwu U.; Adegoke, Oluwasegun J.; Scobie, Heather M.; Uba, Belinda V.; Wannemuehler, Kathleen A.; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J.; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F.
2016-01-01
Background Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Methods Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014–2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12–23 months was documented based on vaccination card or caretaker’s recall. District-level coverage estimates were calculated using survey methods. Results Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1–63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%–139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Conclusions Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues contributing to poor vaccination coverage could serve as an example in countries with sub-optimal vaccination coverage, similar to Nigeria. PMID:27936077
Gunnala, Rajni; Ogbuanu, Ikechukwu U; Adegoke, Oluwasegun J; Scobie, Heather M; Uba, Belinda V; Wannemuehler, Kathleen A; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F
2016-01-01
Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014-2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12-23 months was documented based on vaccination card or caretaker's recall. District-level coverage estimates were calculated using survey methods. Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1-63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%-139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues contributing to poor vaccination coverage could serve as an example in countries with sub-optimal vaccination coverage, similar to Nigeria.
Change-Based Satellite Monitoring Using Broad Coverage and Targetable Sensing
NASA Technical Reports Server (NTRS)
Chien, Steve A.; Tran, Daniel Q.; Doubleday, Joshua R.; Doggett, Thomas
2013-01-01
A generic software framework analyzes data from broad coverage sweeps or general larger areas of interest. Change detection methods are used to extract subsets of directed swath areas that intersect areas of change. These areas are prioritized and allocated to targetable assets. This method is deployed in an automatic fashion, and has operated without human monitoring or intervention for sustained periods of time (months).
TU-AB-BRB-00: New Methods to Ensure Target Coverage
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-06-15
The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less
42 CFR 440.370 - Economy and efficiency.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Economy and efficiency. 440.370 Section 440.370 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS SERVICES: GENERAL PROVISIONS Benchmark Benefit and Benchmark-Equivalent Coverage § 440.370 Economy and efficiency....
7 CFR 457.133 - Prune crop insurance provisions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Provisions that allow optional units by irrigated and non-irrigated practices are not applicable. Instead of establishing optional units by section, section equivalent, or FSA farm serial number optional units may be established if each optional unit is located on non-contiguous land. 3. Insurance Guarantees, Coverage Levels...
7 CFR 457.133 - Prune crop insurance provisions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Provisions that allow optional units by irrigated and non-irrigated practices are not applicable. Instead of establishing optional units by section, section equivalent, or FSA farm serial number optional units may be established if each optional unit is located on non-contiguous land. 3. Insurance Guarantees, Coverage Levels...
42 CFR 440.350 - Employer-sponsored insurance health plans.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Employer-sponsored insurance health plans. 440.350 Section 440.350 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Benchmark-Equivalent Coverage § 440.350 Employer-sponsored insurance health plans. (a) A State may provide...
42 CFR 440.350 - Employer-sponsored insurance health plans.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Employer-sponsored insurance health plans. 440.350 Section 440.350 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Benchmark-Equivalent Coverage § 440.350 Employer-sponsored insurance health plans. (a) A State may provide...
78 FR 217 - Shared Responsibility for Employers Regarding Health Coverage
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-02
..., incapacity (including disability), layoff, jury duty, military duty or leave of absence (29 CFR 2530.200b-2(a... made or due for vacation, holiday, illness, incapacity (including disability), layoff, jury duty...), layoff, jury duty, military duty or leave of absence; (2) using a days-worked equivalency method whereby...
Smith, Blake; Gelover, Edgar; Moignier, Alexandra; Wang, Dongxu; Flynn, Ryan T.; Lin, Liyong; Kirk, Maura; Solberg, Tim; Hyer, Daniel E.
2016-01-01
Purpose: To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). Methods: Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam’s eye view over all energy layers which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%–16.9%) and 5.18% (2.9%–7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%–22.6%) and 8.38% (4.7%–12.0%) for the DCS and fixed aperture plans, respectively. Conclusions: The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans. PMID:27487886
2012-01-01
Background To investigate geometric and dosimetric accuracy of frame-less image-guided radiosurgery (IG-RS) for brain metastases. Methods and materials Single fraction IG-RS was practiced in 72 patients with 98 brain metastases. Patient positioning and immobilization used either double- (n = 71) or single-layer (n = 27) thermoplastic masks. Pre-treatment set-up errors (n = 98) were evaluated with cone-beam CT (CBCT) based image-guidance (IG) and were corrected in six degrees of freedom without an action level. CBCT imaging after treatment measured intra-fractional errors (n = 64). Pre- and post-treatment errors were simulated in the treatment planning system and target coverage and dose conformity were evaluated. Three scenarios of 0 mm, 1 mm and 2 mm GTV-to-PTV (gross tumor volume, planning target volume) safety margins (SM) were simulated. Results Errors prior to IG were 3.9 mm ± 1.7 mm (3D vector) and the maximum rotational error was 1.7° ± 0.8° on average. The post-treatment 3D error was 0.9 mm ± 0.6 mm. No differences between double- and single-layer masks were observed. Intra-fractional errors were significantly correlated with the total treatment time with 0.7mm±0.5mm and 1.2mm±0.7mm for treatment times ≤23 minutes and >23 minutes (p<0.01), respectively. Simulation of RS without image-guidance reduced target coverage and conformity to 75% ± 19% and 60% ± 25% of planned values. Each 3D set-up error of 1 mm decreased target coverage and dose conformity by 6% and 10% on average, respectively, with a large inter-patient variability. Pre-treatment correction of translations only but not rotations did not affect target coverage and conformity. Post-treatment errors reduced target coverage by >5% in 14% of the patients. A 1 mm safety margin fully compensated intra-fractional patient motion. Conclusions IG-RS with online correction of translational errors achieves high geometric and dosimetric accuracy. Intra-fractional errors decrease target coverage and conformity unless compensated with appropriate safety margins. PMID:22531060
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barragán, A. M., E-mail: ana.barragan@uclouvain.be; Differding, S.; Lee, J. A.
Purpose: To prove the ability of protons to reproduce a dose gradient that matches a dose painting by numbers (DPBN) prescription in the presence of setup and range errors, by using contours and structure-based optimization in a commercial treatment planning system. Methods: For two patients with head and neck cancer, voxel-by-voxel prescription to the target volume (GTV{sub PET}) was calculated from {sup 18}FDG-PET images and approximated with several discrete prescription subcontours. Treatments were planned with proton pencil beam scanning. In order to determine the optimal plan parameters to approach the DPBN prescription, the effects of the scanning pattern, number ofmore » fields, number of subcontours, and use of range shifter were separately tested on each patient. Different constant scanning grids (i.e., spot spacing = Δx = Δy = 3.5, 4, and 5 mm) and uniform energy layer separation [4 and 5 mm WED (water equivalent distance)] were analyzed versus a dynamic and automatic selection of the spots grid. The number of subcontours was increased from 3 to 11 while the number of beams was set to 3, 5, or 7. Conventional PTV-based and robust clinical target volumes (CTV)-based optimization strategies were considered and their robustness against range and setup errors assessed. Because of the nonuniform prescription, ensuring robustness for coverage of GTV{sub PET} inevitably leads to overdosing, which was compared for both optimization schemes. Results: The optimal number of subcontours ranged from 5 to 7 for both patients. All considered scanning grids achieved accurate dose painting (1% average difference between the prescribed and planned doses). PTV-based plans led to nonrobust target coverage while robust-optimized plans improved it considerably (differences between worst-case CTV dose and the clinical constraint was up to 3 Gy for PTV-based plans and did not exceed 1 Gy for robust CTV-based plans). Also, only 15% of the points in the GTV{sub PET} (worst case) were above 5% of DPBN prescription for robust-optimized plans, while they were more than 50% for PTV plans. Low dose to organs at risk (OARs) could be achieved for both PTV and robust-optimized plans. Conclusions: DPBN in proton therapy is feasible with the use of a sufficient number subcontours, automatically generated scanning patterns, and no more than three beams are needed. Robust optimization ensured the required target coverage and minimal overdosing, while PTV-approach led to nonrobust plans with excessive overdose. Low dose to OARs can be achieved even in the presence of a high-dose escalation as in DPBN.« less
Varela, Miguel A; Curtis, Helen J; Douglas, Andrew GL; Hammond, Suzan M; O'Loughlin, Aisling J; Sobrido, Maria J; Scholefield, Janine; Wood, Matthew JA
2016-01-01
Allele-specific gene therapy aims to silence expression of mutant alleles through targeting of disease-linked single-nucleotide polymorphisms (SNPs). However, SNP linkage to disease varies between populations, making such molecular therapies applicable only to a subset of patients. Moreover, not all SNPs have the molecular features necessary for potent gene silencing. Here we provide knowledge to allow the maximisation of patient coverage by building a comprehensive understanding of SNPs ranked according to their predicted suitability toward allele-specific silencing in 14 repeat expansion diseases: amyotrophic lateral sclerosis and frontotemporal dementia, dentatorubral-pallidoluysian atrophy, myotonic dystrophy 1, myotonic dystrophy 2, Huntington's disease and several spinocerebellar ataxias. Our systematic analysis of DNA sequence variation shows that most annotated SNPs are not suitable for potent allele-specific silencing across populations because of suboptimal sequence features and low variability (>97% in HD). We suggest maximising patient coverage by selecting SNPs with high heterozygosity across populations, and preferentially targeting SNPs that lead to purine:purine mismatches in wild-type alleles to obtain potent allele-specific silencing. We therefore provide fundamental knowledge on strategies for optimising patient coverage of therapeutics for microsatellite expansion disorders by linking analysis of population genetic variation to the selection of molecular targets. PMID:25990798
Varela, Miguel A; Curtis, Helen J; Douglas, Andrew G L; Hammond, Suzan M; O'Loughlin, Aisling J; Sobrido, Maria J; Scholefield, Janine; Wood, Matthew J A
2016-02-01
Allele-specific gene therapy aims to silence expression of mutant alleles through targeting of disease-linked single-nucleotide polymorphisms (SNPs). However, SNP linkage to disease varies between populations, making such molecular therapies applicable only to a subset of patients. Moreover, not all SNPs have the molecular features necessary for potent gene silencing. Here we provide knowledge to allow the maximisation of patient coverage by building a comprehensive understanding of SNPs ranked according to their predicted suitability toward allele-specific silencing in 14 repeat expansion diseases: amyotrophic lateral sclerosis and frontotemporal dementia, dentatorubral-pallidoluysian atrophy, myotonic dystrophy 1, myotonic dystrophy 2, Huntington's disease and several spinocerebellar ataxias. Our systematic analysis of DNA sequence variation shows that most annotated SNPs are not suitable for potent allele-specific silencing across populations because of suboptimal sequence features and low variability (>97% in HD). We suggest maximising patient coverage by selecting SNPs with high heterozygosity across populations, and preferentially targeting SNPs that lead to purine:purine mismatches in wild-type alleles to obtain potent allele-specific silencing. We therefore provide fundamental knowledge on strategies for optimising patient coverage of therapeutics for microsatellite expansion disorders by linking analysis of population genetic variation to the selection of molecular targets.
Impact of organ shape variations on margin concepts for cervix cancer ART.
Seppenwoolde, Yvette; Stock, Markus; Buschmann, Martin; Georg, Dietmar; Bauer-Novotny, Kwei-Yuang; Pötter, Richard; Georg, Petra
2016-09-01
Target and organ movement motivate adaptive radiotherapy for cervix cancer patients. We investigated the dosimetric impact of margin concepts with different levels of complexity on both organ at risk (OAR) sparing and PTV coverage. Weekly CT and daily CBCT scans were delineated for 10 patients. The dosimetric impact of organ shape variations were evaluated for four (isotropic) margin concepts: two static PTVs (PTV 6mm and PTV 15mm ), a PTV based on ITV of the planning CT and CBCTs of the first treatment week (PTV ART ITV ) and an adaptive PTV based on a library approach (PTV ART Library ). Using static concepts, OAR doses increased with large margins, while smaller margins compromised target coverage. ART PTVs resulted in comparable target coverage and better sparing of bladder (V40Gy: 15% and 7% less), rectum (V40Gy: 18 and 6cc less) and bowel (V40Gy: 106 and 15cc less) compared to PTV 15mm . Target coverage evaluation showed that for elective fields a static 5mm margin sufficed. PTV ART Library achieved the best dosimetric results. However when weighing clinical benefit against workload, ITV margins based on repetitive movement evaluation during the first week also provide improvements over static margin concepts. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Massing, Louis Albert; Aboubakar, Soumah; Page, Anne-Laure; Cohuet, Sandra; Ngandwe, Adalbert; Mukomena Sompwe, Eric; Ramazani, Romain; Allheimen, Marcela; Levaillant, Philippe; Lechevalier, Pauline; Kashimi, Marie; de la Motte, Axelle; Calmejane, Arielle; Bouhenia, Malika; Dabire, Ernest; Bompangue, Didier; Kebela, Benoit; Porten, Klaudia
2018-01-01
Introduction Oral cholera vaccines are primarily recommended by the World Health Organization for cholera control in endemic countries. However, the number of cholera vaccines currently produced is very limited and examples of OCV use in endemic countries, and especially in urban settings, are scarce. A vaccination campaign was organized by Médecins Sans Frontières and the Ministry of Health in a highly endemic area in the Democratic Republic of Congo. This study aims to describe the vaccine coverage achieved with this highly targeted vaccination campaign and the acceptability among the vaccinated communities. Methods and findings We performed a cross-sectional survey using random spatial sampling. The study population included individuals one year old and above, eligible for vaccination, and residing in the areas targeted for vaccination in the city of Kalemie. Data sources were household interviews with verification by vaccination card. In total 2,488 people were included in the survey. Overall, 81.9% (95%CI: 77.9–85.3) of the target population received at least one dose of vaccine. The vaccine coverage with two doses was 67.2% (95%CI: 61.9–72.0) among the target population. The vaccine coverage was higher during the first round (74.0, 95%CI: 69.3–78.3) than during the second round of vaccination (69.1%, 95%CI: 63.9–74.0). Vaccination coverage was lower in male adults. The main reason for non-vaccination was to be absent during the campaign. No severe adverse events were notified during the interviews. Conclusions Cholera vaccination campaigns using highly targeted strategies are feasible in urban settings. High vaccination coverage can be obtained using door to door vaccination. However, alternative strategies should be considered to reach non-vaccinated populations like male adults and also in order to improve the efficiency of the interventions. PMID:29734337
A novel dose-based positioning method for CT image-guided proton therapy
Cheung, Joey P.; Park, Peter C.; Court, Laurence E.; Ronald Zhu, X.; Kudchadker, Rajat J.; Frank, Steven J.; Dong, Lei
2013-01-01
Purpose: Proton dose distributions can potentially be altered by anatomical changes in the beam path despite perfect target alignment using traditional image guidance methods. In this simulation study, the authors explored the use of dosimetric factors instead of only anatomy to set up patients for proton therapy using in-room volumetric computed tomographic (CT) images. Methods: To simulate patient anatomy in a free-breathing treatment condition, weekly time-averaged four-dimensional CT data near the end of treatment for 15 lung cancer patients were used in this study for a dose-based isocenter shift method to correct dosimetric deviations without replanning. The isocenter shift was obtained using the traditional anatomy-based image guidance method as the starting position. Subsequent isocenter shifts were established based on dosimetric criteria using a fast dose approximation method. For each isocenter shift, doses were calculated every 2 mm up to ±8 mm in each direction. The optimal dose alignment was obtained by imposing a target coverage constraint that at least 99% of the target would receive at least 95% of the prescribed dose and by minimizing the mean dose to the ipsilateral lung. Results: The authors found that 7 of 15 plans did not meet the target coverage constraint when using only the anatomy-based alignment. After the authors applied dose-based alignment, all met the target coverage constraint. For all but one case in which the target dose was met using both anatomy-based and dose-based alignment, the latter method was able to improve normal tissue sparing. Conclusions: The authors demonstrated that a dose-based adjustment to the isocenter can improve target coverage and/or reduce dose to nearby normal tissue. PMID:23635262
Restricted Field IMRT Dramatically Enhances IMRT Planning for Mesothelioma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, Aaron M.; Schofield, Deborah; Hacker, Fred
2007-12-01
Purpose: To improve the target coverage and normal tissue sparing of intensity-modulated radiotherapy (IMRT) for mesothelioma after extrapleural pneumonectomy. Methods and Materials: Thirteen plans from patients previously treated with IMRT for mesothelioma were replanned using a restricted field technique. This technique was novel in two ways. It limited the entrance beams to 200{sup o} around the target and three to four beams per case had their field apertures restricted down to the level of the heart or liver to further limit the contralateral lung dose. New constraints were added that included a mean lung dose of <9.5 Gy and volumemore » receiving {>=}5 Gy of <55%. Results: In all cases, the planning target volume coverage was excellent, with an average of 97% coverage of the planning target volume by the target dose. No change was seen in the target coverage with the new technique. The heart, kidneys, and esophagus were all kept under tolerance in all cases. The average mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy with the new technique was 6.6 Gy, 3.0%, and 50.8%, respectively, compared with 13.8 Gy, 15%, and 90% with the previous technique (p < 0.0001 for all three comparisons). The maximal value for any case in the cohort was 8.0 Gy, 7.3%, and 57.5% for the mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy, respectively. Conclusion: Restricted field IMRT provides an improved method to deliver IMRT to a complex target after extrapleural pneumonectomy. An upcoming Phase I trial will provide validation of these results.« less
Persistence with biologic therapies in the Medicare coverage gap.
Tamariz, Leonardo; Uribe, Claudia L; Luo, Jiacong; Hanna, John W; Ball, Daniel E; Krohn, Kelly; Meadows, Eric S
2011-11-01
To describe persistence with teriparatide and other biologic therapies in Medicare Part D plans with and without a coverage gap. Retrospective (2006) cohort study of Medicare Part D prescription drug plan beneficiaries from a large benefits company. Two plans with a coverage gap (defined as "basic") were combined and compared with a single plan with coverage for generic and branded medications (defined as "complete"). Patients taking alendronate (nonbiologic comparator), teriparatide, etanercept, adalimumab, interferon β-1a, or glatiramer acetate were selected for the study. For patients with complete coverage, equivalent financial thresholds were used to define the "gap."The definition of discontinuation was failure to fill the index prescription after reaching the gap. For alendronate, 27% of 133,260 patients had enrolled in the complete plan. Patients taking biologic therapies had more commonly enrolled in complete plans: teriparatide (66% of 6221), etanercept (58% of 1469), adalimumab (52% of 824), interferon β-1a (60% of 438), and glatiramer acetate (53% of 393). For patients taking either alendronate or teriparatide, discontinuation rates were higher in the basic, versus complete, plan (adjusted odds ratios, 2.02 and 3.56, respectively). Discontinuation did not significantly vary by plan type for etanercept, adalimumab, interferon β-1a, or glatiramer acetate. For patients who reached the coverage gap, discontinuation was more likely for patients taking osteoporosis (OP) medication. Not having a coverage gap was associated with improved persistence with OP treatment.
Delaunay Triangulation as a New Coverage Measurement Method in Wireless Sensor Network
Chizari, Hassan; Hosseini, Majid; Poston, Timothy; Razak, Shukor Abd; Abdullah, Abdul Hanan
2011-01-01
Sensing and communication coverage are among the most important trade-offs in Wireless Sensor Network (WSN) design. A minimum bound of sensing coverage is vital in scheduling, target tracking and redeployment phases, as well as providing communication coverage. Some methods measure the coverage as a percentage value, but detailed information has been missing. Two scenarios with equal coverage percentage may not have the same Quality of Coverage (QoC). In this paper, we propose a new coverage measurement method using Delaunay Triangulation (DT). This can provide the value for all coverage measurement tools. Moreover, it categorizes sensors as ‘fat’, ‘healthy’ or ‘thin’ to show the dense, optimal and scattered areas. It can also yield the largest empty area of sensors in the field. Simulation results show that the proposed DT method can achieve accurate coverage information, and provides many tools to compare QoC between different scenarios. PMID:22163792
Cognate status and cross-script translation priming.
Voga, Madeleine; Grainger, Jonathan
2007-07-01
Greek-French bilinguals were tested in three masked priming experiments with Greek primes and French targets. Related primes were the translation equivalents of target words, morphologically related to targets, or phonologically related to targets. In Experiment 1, cognate translation equivalents (phonologically similar translations) showed facilitatory priming, relative to matched phonologically related primes, in conditions in which morphologically related primes showed no effect (50-msec prime exposure). Cross-language morphological priming emerged at longer prime exposure durations (66 msec), but cognate primes continued to generate more priming than did those in the morphological condition. In Experiments 2 and 3, the level of phonological overlap across translation equivalents was varied, and priming effects were measured against those for matched phonologically related primes and those in an unrelated prime condition. When measured against the unrelated baseline, cognate primes showed the typical advantage over noncognate primes. However, this cognate advantage disappeared when priming was measured against the phonologically related prime condition. The results are discussed in terms of how translation equivalents are represented in bilingual memory.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-25
... in 2014, all non-grandfathered health insurance coverage in the individual and small group markets... PHS Act directs non-grandfathered group health plans to ensure that cost- sharing under the plan does... individual and small group markets, and not to Medicaid benchmark or benchmark-equivalent plans. In a...
42 CFR 457.431 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... standardized set of utilization and price factors; (4) Using a standardized population that is representative... means of cost control or utilization used; and (7) Taking into account the ability of a State to reduce... population to be used under paragraphs (b)(3) and (b)(4) of this section. (d) The State must provide...
42 CFR 457.431 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... standardized set of utilization and price factors; (4) Using a standardized population that is representative... means of cost control or utilization used; and (7) Taking into account the ability of a State to reduce... population to be used under paragraphs (b)(3) and (b)(4) of this section. (d) The State must provide...
42 CFR 457.431 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... standardized set of utilization and price factors; (4) Using a standardized population that is representative... means of cost control or utilization used; and (7) Taking into account the ability of a State to reduce... population to be used under paragraphs (b)(3) and (b)(4) of this section. (d) The State must provide...
42 CFR 457.431 - Actuarial report for benchmark-equivalent coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... standardized set of utilization and price factors; (4) Using a standardized population that is representative... means of cost control or utilization used; and (7) Taking into account the ability of a State to reduce... population to be used under paragraphs (b)(3) and (b)(4) of this section. (d) The State must provide...
The Australian Press and Education: A Survey of National and Global Perspectives.
ERIC Educational Resources Information Center
Woolman, David C.
The news media are often the main source of public information about education. This paper analyzes press coverage of selected issues in contemporary Australian education. From December 28, 1998, to February 17, 1999, daily educational reporting was surveyed in "The Australian" (a paper roughly equivalent to "USA Today") and in…
42 CFR 486.102 - Condition for coverage: Supervision by a qualified physician.
Code of Federal Regulations, 2010 CFR
2010-10-01
... diagnostic purposes, i.e., he (1) is certified in radiology by the American Board of Radiology or by the American Osteopathic Board of Radiology or possesses qualifications which are equivalent to those required... purposes, or (3) specializes in radiology and is recognized by the medical community as a specialist in...
Massat, Nathalie J; Douglas, Elaine; Waller, Jo; Wardle, Jane; Duffy, Stephen W
2015-07-24
Reducing cancer screening inequalities in England is a major focus of the 2011 Department of Health cancer outcome strategy. Screening coverage requires regular monitoring in order to implement targeted interventions where coverage is low. This study aimed to characterise districts with atypical coverage levels for cervical or breast screening. Observational study of district-level coverage in the English Cervical and Breast screening programmes in 2012. England, UK. All English women invited to participate in the cervical (age group 25-49 and 50-64) and breast (age group 50-64) screening programmes. Risk adjustment models for coverage were developed based on district-level characteristics. Funnel plots of adjusted coverage were constructed, and atypical districts examined by correlation analysis. Variability in coverage was primarily explained by population factors, whereas general practice characteristics had little independent effect. Deprivation and ethnicity other than white, Asian, black or mixed were independently associated with poorer coverage in both screening programmes, with ethnicity having the strongest effect; by comparison, the influence of Asian, black or mixed ethnic minority was limited. Deprivation, ethnicity and urbanisation largely accounted for the lower cervical screening coverage in London. However, for breast screening, being located in London remained a strong negative predictor. A subset of districts was identified as having atypical coverage across programmes. Correlates of deprivation in districts with relatively low adjusted coverage were substantially different from overall correlates of deprivation. These results inform the continuing drive to reduce avoidable cancer deaths in England, and encourage implementation of targeted interventions in communities residing in districts identified as having atypically low coverage. Sequential implementation to monitor the impact of local interventions would help accrue evidence on 'what works'. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
TU-AB-BRB-01: Coverage Evaluation and Probabilistic Treatment Planning as a Margin Alternative
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siebers, J.
The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, H.
The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less
Shuaibu, Faisal M; Birukila, Gerida; Usman, Samuel; Mohammed, Ado; Galway, Michael; Corkum, Melissa; Damisa, Eunice; Mkanda, Pascal; Mahoney, Frank; Wa Nganda, Gatei; Vertefeuille, John; Chavez, Anna; Meleh, Sule; Banda, Richard; Some, Almai; Mshelia, Hyelni; Umar, Al-Umra; Enemaku, Ogu; Etsano, Andrew
2016-02-01
The use of Inactivated Polio Vaccine (IPV) in routine immunization to replace Oral Polio Vaccine (OPV) is crucial in eradicating polio. In June 2014, Nigeria launched an IPV campaign in the conflict-affected states of Borno and Yobe, the largest ever implemented in Africa. We present the initiatives and lessons learned. The 8-day event involved two parallel campaigns. OPV target age was 0-59 months, while IPV targeted all children aged 14 weeks to 59 months. The Borno state primary health care agency set up temporary health camps for the exercise and treated minor ailments for all. The target population for the OPV campaign was 685,674 children in Borno and 113,774 in Yobe. The IPV target population for Borno was 608,964 and for Yobe 111,570. OPV coverage was 105.1 per cent for Borno and 103.3 per cent for Yobe. IPV coverage was 102.9 per cent for Borno and 99.1 per cent for Yobe. (Where we describe coverage as greater than 100 per cent, this reflects original underestimates of the target populations.) A successful campaign and IPV immunization is viable in conflict areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scorsetti, Marta; Bignardi, Mario; Clivio, Alessandro
Purpose: A planning study was performed to evaluate RapidArc (RA), a volumetric modulated arc technique, on malignant pleural mesothelioma. The benchmark was conventional fixed-field intensity-modulated radiotherapy (IMRT). Methods and materials: The computed tomography data sets of 6 patients were included. The plans for IMRT with nine fixed beams were compared against double-modulated arcs with a single isocenter. All plans were optimized for 15-MV photon beams. The dose prescription was 54 Gy to the planning target volume. The planning objectives for the planning target volume were a minimal dose of >95% and maximal dose of <107%. For the organs at risk,more » the parameters were as follows: contralateral lung, percentage of volume receiving 5 Gy (V{sub 5Gy}) <60%, V{sub 20Gy} < 10%, mean <10.0 Gy; liver, V{sub 30Gy} <33%, mean <31 Gy; heart, V{sub 45Gy} <30%, V{sub 50Gy} <20%, dose received by 1% of the volume (D{sub 1%}) <60 Gy; contralateral kidney, V{sub 15Gy} <20%; spine, D{sub 1%} <45 Gy; esophagus, V{sub 55Gy} <30%; and spleen, V{sub 40Gy} <50%. The monitor units (MUs) and delivery time were scored to measure the treatment efficiency. The pretreatment portal dosimetry scored delivery to the calculation agreement with the Gamma Agreement Index. Results: RA and IMRT provided equivalent coverage and homogeneity. Both techniques fulfilled objectives on organs at risk with a tendency of RA to improve sparing. The conformity index was 1.9 {+-} 0.1 for RA and IMRT. The number of MU/2Gy was 734 {+-} 82 for RA and 2,195 {+-} 317 for IMRT. The planning vs. delivery agreement revealed a Gamma Agreement Index for IMRT of 96.0% {+-} 2.6% and for RA of 95.7% {+-} 1.5%. The treatment time was 3.7 {+-} 0.3min for RA and 13.4 {+-} 0.1min for IMRT. Conclusion: RA demonstrated compared with conventional IMRT, similar target coverage and better dose sparing to the organs at risks. The number of MUs and the time required to deliver a 2-Gy fraction were much lower for RA, allowing the possibility to incorporate this technique in the treatment options for mesothelioma patients.« less
ABP 980: promising trastuzumab biosimilar for HER2-positive breast cancer.
Paplomata, Elisavet; Nahta, Rita
2018-03-01
Approval of the HER2-targeted antibody trastuzumab dramatically improved outcomes for patients with HER2-positive breast cancer. Multiple trastuzumab biosimilars, including ABP 980, are in clinical development. Biosimilars are not identical to the reference biologic, but exhibit equivalence and safety in analytical and clinical studies. Areas covered: A brief introduction to trastuzumab, overview of trastuzumab biosimilars, and detailed review of ABP 980 preclinical and clinical studies are included. We searched PubMed and 2016-2017 ASCO and ESMO conference proceedings for 'ABP 980' or 'trastuzumab biosimilar'. 'ABP 980 and breast cancer' or 'trastuzumab biosimilar and breast cancer' were used to search clinicaltrials.gov for phase III trials. Analytical studies of ABP 980 pharmacokinetics (PK) or pharmacodynamics (PD), phase I studies of ABP 980 safety and PK/PD, and phase III studies of clinical efficacy vs trastuzumab are included. Expert opinion: Questions remain regarding long-term impact of biosimilars on overall healthcare costs, insurance coverage of multiple approved biosimilars, and extensive clinical safety and efficacy follow-up. By producing a competitive market, trastuzumab biosimilars are anticipated to improve access to standard of care therapies, although real-world evidence remains to be obtained. Increased global access to HER2-targeted therapy may eventually alter the landscape of breast cancer and survival rates.
Zöllner, Caroline; De Allegri, Manuela; Louis, Valérie R; Yé, Maurice; Sié, Ali; Tiendrebéogo, Justin; Jahn, Albrecht; Müller, Olaf
2015-03-01
Insecticide-treated mosquito nets (ITNs) are an essential tool of the Roll Back Malaria strategy. An increasing number of African countries have embarked on mass distribution campaigns of long-lasting insecticide-treated nets (LLINs) with the ultimate goal of universal coverage. Such a national campaign with the goal of one ITN for every two people has been conducted in Burkina Faso in 2010. Our aim was to assess the coverage and equity effect of the universal distribution campaign of LLINs in Burkina Faso and to identify determinants of ITN ownership across households after the campaign. We evaluated its effects through comparison of data from two household surveys conducted in early 2010 (before the campaign) and early 2011 (after the campaign) on a representative rural district in north-western Burkina Faso. Data were collected on household characteristics (including socio-economic status) and ITN ownership. We used concentration curves and indices to compare ITN coverage indicators before and after the campaign and multilevel multivariate logistic regression to estimate factors associated with achievement of the universal coverage target in 2011. The survey included 1106 households in 2010 and 1094 in 2011. We found that the proportion of households with at least one ITN increased from 59% before the campaign to 99% afterwards, whereas the concentration index dropped from 0.087 (standard error (SE): 0.014) to 0.002 (SE: 0.002). Fifty-two per cent of households reached the target of one ITN for every two people per household, with the relevant concentration index at -0.031 (SE: 0.016). Eighty-six per cent of households owned at least one ITN for every three people. The main characteristics significantly associated with the targeted intra-household coverage were family size and distance to the health centre but not socio-economic status. In conclusion, despite not having fully met its target, the national LLIN campaign achieved a high level of coverage and fostered equity. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2014; all rights reserved.
NASA Astrophysics Data System (ADS)
Wu, Zhibo; Zhang, Haifeng; Zhang, Zhongping; Deng, Huarong; Li, Pu; Meng, Wendong; Cheng, Zhien; Shen, Lurun; Tang, Zhenhong
2014-11-01
Laser ranging technology can directly measure the distance between space targets and ground stations with the highest measurement precision and will play an irreplaceable role in orbit check and calibrating microwave measurement system. The precise orbit determination and accurate catalogue of space targets can also be realized by laser ranging with multi-stations. Among space targets, most of ones are inactive targets and space debris, which should be paid the great attentions for the safety of active spacecrafts. Because of laser diffuse reflection from the surface of targets, laser ranging to space debris has the characteristics of wide coverage and weak strength of laser echoes, even though the powerful laser system is applied. In order to increase the receiving ability of laser echoes, the large aperture telescope should be adopted. As well known, some disadvantages for one set of large aperture telescope, technical development difficulty and system running and maintenance complexity, will limit its flexible applications. The multi-receiving telescopes technology in laser ranging to space targets is put forward to realize the equivalent receiving ability produced by one larger aperture telescope by way of using multi-receiving telescopes, with the advantages of flexibility and maintenance. The theoretical analysis of the feasibility and key technologies of multi-receiving telescopes technology in laser ranging to space targets are presented in this paper. The experimental measurement system based on the 60cm SLR system and 1.56m astronomical telescopes with a distance of about 50m is established to provide the platform for researching on the multi-receiving telescopes technology. The laser ranging experiments to satellites equipped with retro-reflectors are successfully performed by using the above experimental system and verify the technical feasibility to increase the ability of echo detection. And the multi-receiving telescopes technology will become a novel effective way to improve the detection ability of laser ranging to space debris.
Mereckiene, J; Cotter, S; Nicoll, A; Lopalco, P; Noori, T; Weber, Jt; D'Ancona, F; Levy-Bruhl, D; Dematte, L; Giambi, C; Valentiner-Branth, P; Stankiewicz, I; Appelgren, E; O Flanagan, D
2014-04-24
Since 2008, annual surveys of influenza vaccination policies, practices and coverage have been undertaken in 29 European Union (EU)/ European Economic Area (EEA) countries. After 2009, this monitored the impact of European Council recommendation to increase vaccination coverage to 75% among risk groups. This paper summarises the results of three seasonal influenza seasons: 2008/09, 2009/10 and 2010/11. In 2008/09, 27/29 countries completed the survey; in 2009/10 and 2010/11, 28/29 completed it. All or almost all countries recommended vaccination of older people (defined as those aged ≥50, ≥55, ≥59, ≥60 or ≥65 years), and people aged ≥6 months with clinical risk and healthcare workers. A total of 23 countries provided vaccination coverage data for older people, but only 7 and 10 had data for the clinical risk groups and healthcare workers, respectively. The number of countries recommending vaccination for some or all pregnant women increased from 10 in 2008/09 to 22 in 2010/11. Only three countries could report coverage among pregnant women. Seasonal influenza vaccination coverage during and after the pandemic season in older people and clinical groups remained unchanged in countries with higher coverage. However, small decreases were seen in most countries during this period. The results of the surveys indicate that most EU/EEA countries recommend influenza vaccination for the main target groups; however, only a few countries have achieved the target of 75% coverage among risk groups. Coverage among healthcare workers remained low.
Varan, Aiden K; Rodriguez-Lainz, Alfonso; Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Li, Qian
2017-08-01
Healthy People 2020 targets high vaccination coverage among children. Although reductions in coverage disparities by race/ethnicity have been described, data by nativity are limited. The National Immunization Survey is a random-digit-dialed telephone survey that estimates vaccination coverage among U.S. children aged 19-35 months. We assessed coverage among 52,441 children from pooled 2010-2012 data for individual vaccines and the combined 4:3:1:3*:3:1:4 series (which includes ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine/diphtheria and tetanus toxoids vaccine/diphtheria, tetanus toxoids, and pertussis vaccine, ≥3 doses of poliovirus vaccine, ≥1 dose of measles-containing vaccine, ≥3 or ≥4 doses of Haemophilus influenzae type b vaccine (depending on product type of vaccine; denoted as 3* in the series name), ≥3 doses of hepatitis B vaccine, ≥1 dose of varicella vaccine, and ≥4 doses of pneumococcal conjugate vaccine). Coverage estimates controlling for sociodemographic factors and multivariable logistic regression modeling for 4:3:1:3*:3:1:4 series completion are presented. Significantly lower coverage among foreign-born children was detected for DTaP, hepatitis A, hepatitis B, Hib, pneumococcal conjugate, and rotavirus vaccines, and for the combined series. Series completion disparities persisted after control for demographic, access-to-care, poverty, and language effects. Substantial and potentially widening disparities in vaccination coverage exist among foreign-born children. Improved immunization strategies targeting this population and continued vaccination coverage monitoring by nativity are needed.
Dedicated breast CT: geometric design considerations to maximize posterior breast coverage
NASA Astrophysics Data System (ADS)
Vedantham, Srinivasan; Karellas, Andrew; Emmons, Margaret M.; Moss, Lawrence J.; Hussain, Sarwat; Baker, Stephen P.
2013-06-01
An Institutional Review Board-approved protocol was used to quantify breast tissue inclusion in 52 women, under conditions simulating both craniocaudal (CC) and mediolateral oblique (MLO) views in mammography, dedicated breast CT in the upright subject position, and dedicated breast CT in the prone subject position. Using skin as a surrogate for the underlying breast tissue, the posterior aspect of the breast that is aligned with the chest-wall edge of the breast support in a screen-film mammography system was marked with the study participants positioned for CC and MLO views. The union of skin marks with the study participants positioned for CC and MLO views was considered to represent chest-wall tissue available for imaging with mammography and served as the reference standard. For breast CT, a prone stereotactic breast biopsy unit and a custom-fabricated barrier were used to simulate conditions during prone and upright breast CT, respectively. For the same breast marked on the mammography system, skin marks were made along the breast periphery that was just anterior to the apertures of the prone biopsy unit and the upright barrier. The differences in skin marks between subject positioning simulating breast CT (prone, upright) and mammography were quantified at six anatomic locations. For each location, at least one study participant had a skin mark from breast CT (prone, upright) posterior to mammography. However for all study participants, there was at least one anatomic location where the skin mark from mammography was posterior to that from breast CT (prone, upright) positioning. The maximum amount by which the skin mark from mammography was posterior to breast CT (prone and upright) over all six locations was quantified for each study participant and pair-wise comparison did not exhibit statistically significant difference between prone and upright breast CT (paired t- test, p = 0.4). Quantitatively, for 95% of the study participants the skin mark from mammography was posterior to breast CT (prone or upright) by at the most 9 mm over all six locations. Based on the study observations, geometric design considerations targeting chest-wall coverage with breast CT equivalent to mammography, wherein part of the x-ray beam images through the swale during breast CT are provided. Assuming subjects can extend their chest in to a swale, the optimal swale-depth required to achieve equivalent coverage with breast CT images as mammograms for 95% of the subjects varies in the range of ˜30-50 mm for clinical prototypes and was dependent on the system geometry.
Sources and Coverage of Medical News on Front Pages of US Newspapers
Lai, William Y. Y.; Lane, Trevor; Jones, Alison
2009-01-01
Background Medical news that appears on newspaper front pages is intended to reach a wide audience, but how this type of medical news is prepared and distributed has not been systematically researched. We thus quantified the level of visibility achieved by front-page medical stories in the United States and analyzed their news sources. Methodology Using the online resource Newseum, we investigated front-page newspaper coverage of four prominent medical stories, and a high-profile non-medical news story as a control, reported in the US in 2007. Two characteristics were quantified by two raters: which newspaper titles carried each target front-page story (interrater agreement, >96%; kappa, >0.92) and the news sources of each target story (interrater agreement, >94%; kappa, >0.91). National rankings of the top 200 US newspapers by audited circulation were used to quantify the extent of coverage as the proportion of the total circulation of ranked newspapers in Newseum. Findings In total, 1630 front pages were searched. Each medical story appeared on the front pages of 85 to 117 (67.5%–78.7%) ranked newspaper titles that had a cumulative daily circulation of 23.1 to 33.4 million, or 61.8% to 88.4% of all newspapers. In contrast, the non-medical story achieved front-page coverage in 152 (99.3%) newspaper titles with a total circulation of 41.0 million, or 99.8% of all newspapers. Front-page medical stories varied in their sources, but the Washington Post, Los Angeles Times, New York Times and the Associated Press together supplied 61.7% of the total coverage of target front-page medical stories. Conclusion Front-page coverage of medical news from different sources is more accurately revealed by analysis of circulation counts rather than of newspaper titles. Journals wishing to widen knowledge of research news and organizations with important health announcements should target at least the four dominant media organizations identified in this study. PMID:19724643
Vugmeyster, Yulia; Rohde, Cynthia; Perreault, Mylene; Gimeno, Ruth E; Singh, Pratap
2013-01-01
TAM-163, an agonist monoclonal antibody targeting tyrosine receptor kinase-B (TrkB), is currently being investigated as a potential body weight modulatory agent in humans. To support the selection of the dose range for the first-in-human (FIH) trial of TAM-163, we conducted a mechanistic analysis of the pharmacokinetic (PK) and pharmacodynamic (PD) data (e.g., body weight gain) obtained in lean cynomolgus and obese rhesus monkeys following single doses ranging from 0.3 to 60 mg/kg. A target-mediated drug disposition (TMDD) model was used to describe the observed nonlinear PK and Emax approach was used to describe the observed dose-dependent PD effect. The TMDD model development was supported by the experimental determination of the binding affinity constant (9.4 nM) and internalization rate of the drug-target complex (2.08 h(-1)). These mechanistic analyses enabled linking of exposure, target (TrkB) coverage, and pharmacological activity (e.g., PD) in monkeys, and indicated that ≥ 38% target coverage (time-average) was required to achieve significant body weight gain in monkeys. Based on the scaling of the TMDD model from monkeys to humans and assuming similar relationship between the target coverage and pharmacological activity between monkey and humans, subcutaneous (SC) doses of 1 and 15 mg/kg in humans were projected to be the minimally and the fully pharmacologically active doses, respectively. Based on the minimal anticipated biological effect level (MABEL) approach for starting dose selection, the dose of 0.05 mg/kg (3 mg for a 60 kg human) SC was recommended as the starting dose for FIH trials, because at this dose level<10% target coverage was projected at Cmax (and all other time points). This study illustrates a rational mechanistic approach for the selection of FIH dose range for a therapeutic protein with a complex model of action.
Metcalf, C J E; Tatem, A; Bjornstad, O N; Lessler, J; O'Reilly, K; Takahashi, S; Cutts, F; Grenfell, B T
2015-05-01
Measles vaccination is estimated to have averted 13·8 million deaths between 2000 and 2012. Persisting heterogeneity in coverage is a major contributor to continued measles mortality, and a barrier to measles elimination and introduction of rubella-containing vaccine. Our objective is to identify determinants of inequities in coverage, and how vaccine delivery must change to achieve elimination goals, which is a focus of the WHO Decade of Vaccines. We combined estimates of travel time to the nearest urban centre (⩾50 000 people) with vaccination data from Demographic Health Surveys to assess how remoteness affects coverage in 26 African countries. Building on a statistical mapping of coverage against age and geographical isolation, we quantified how modifying the rate and age range of vaccine delivery affects national coverage. Our scenario analysis considers increasing the rate of delivery of routine vaccination, increasing the target age range of routine vaccination, and enhanced delivery to remote areas. Geographical isolation plays a key role in defining vaccine inequity, with greater inequity in countries with lower measles vaccine coverage. Eliminating geographical inequities alone will not achieve thresholds for herd immunity, indicating that changes in delivery rate or age range of routine vaccination will be required. Measles vaccine coverage remains far below targets for herd immunity in many countries on the African continent and is likely to be inadequate for achieving rubella elimination. The impact of strategies such as increasing the upper age range eligible for routine vaccination should be considered.
Is universal health coverage the practical expression of the right to health care?
Ooms, Gorik; Latif, Laila A; Waris, Attiya; Brolan, Claire E; Hammonds, Rachel; Friedman, Eric A; Mulumba, Moses; Forman, Lisa
2014-02-24
The present Millennium Development Goals are set to expire in 2015 and their next iteration is now being discussed within the international community. With regards to health, the World Health Organization proposes universal health coverage as a 'single overarching health goal' for the next iteration of the Millennium Development Goals.The present Millennium Development Goals have been criticised for being 'duplicative' or even 'competing alternatives' to international human rights law. The question then arises, if universal health coverage would indeed become the single overarching health goal, replacing the present health-related Millennium Development Goals, would that be more consistent with the right to health? The World Health Organization seems to have anticipated the question, as it labels universal health coverage as "by definition, a practical expression of the concern for health equity and the right to health".Rather than waiting for the negotiations to unfold, we thought it would be useful to verify this contention, using a comparative normative analysis. We found that--to be a practical expression of the right to health--at least one element is missing in present authoritative definitions of universal health coverage: a straightforward confirmation that international assistance is essential, not optional.But universal health coverage is a 'work in progress'. A recent proposal by the United Nations Sustainable Development Solutions Network proposed universal health coverage with a set of targets, including a target for international assistance, which would turn universal health coverage into a practical expression of the right to health care.
Seo, Jeongmin; Lim, Juwon
2018-05-05
Influenza is a major cause of morbidity and mortality worldwide. Annual vaccination is effective in its prevention and is recommended especially in susceptible populations such as the elderly over 65 years, children younger than 5, pregnant women, and people with chronic diseases. Overall, South Korea has a high vaccination rate owing to its National Immunization Program, although the method and extent of its coverage varies among the target subgroups. The aim of this study is to assess the trend of influenza vaccination coverage between 2005 and 2014 in South Korea to address the influence of sociodemographic and disease factors on vaccination behavior. Also, we aim to compare the vaccination coverage of target subgroups and evaluate the effect of relevant policies to provide suggestions for their improvement. A total of 61,036 respondents from the Korea National Health and Nutrition Examination Surveys III to VI were included. The total influenza vaccination coverage increased from 38.0% in 2005 to 44.1% in 2014. Vaccination coverage was higher among the elderly aged ≥65 years (range, 70.0-79.8%; p-for-trend <0.001) and children under 5 (range, 64.6-78.9%; p-for-trend < 0.001) than among pregnant women (range, 9.4-37.8%; p-for-trend = 0.122) and people with chronic diseases (range, 29.6-42.6%; p-for-trend = 0.068) from 2005 to 2014. High vaccination coverage was associated with female gender, rural residence, low education level, high income, and increasing number of chronic diseases. But the effect of high income on high vaccination coverage was absent in the elderly aged ≥65 years and children under 5. Influenza vaccination rates have steadily increased from 2005 to 2014 in South Korea. Disparities between target groups correspond to their financial coverage under the National Immunization Program, and financial aids remove the influence of high income on higher vaccination rates. Future vaccination policies should focus on pregnant women and people with chronic diseases. Copyright © 2018 Elsevier Ltd. All rights reserved.
Shi, Binbin; Wei, Wei; Wang, Yihuai; Shu, Wanneng
2016-01-01
In high-density sensor networks, scheduling some sensor nodes to be in the sleep mode while other sensor nodes remain active for monitoring or forwarding packets is an effective control scheme to conserve energy. In this paper, a Coverage-Preserving Control Scheduling Scheme (CPCSS) based on a cloud model and redundancy degree in sensor networks is proposed. Firstly, the normal cloud model is adopted for calculating the similarity degree between the sensor nodes in terms of their historical data, and then all nodes in each grid of the target area can be classified into several categories. Secondly, the redundancy degree of a node is calculated according to its sensing area being covered by the neighboring sensors. Finally, a centralized approximation algorithm based on the partition of the target area is designed to obtain the approximate minimum set of nodes, which can retain the sufficient coverage of the target region and ensure the connectivity of the network at the same time. The simulation results show that the proposed CPCSS can balance the energy consumption and optimize the coverage performance of the sensor network. PMID:27754405
Shi, Binbin; Wei, Wei; Wang, Yihuai; Shu, Wanneng
2016-10-14
In high-density sensor networks, scheduling some sensor nodes to be in the sleep mode while other sensor nodes remain active for monitoring or forwarding packets is an effective control scheme to conserve energy. In this paper, a Coverage-Preserving Control Scheduling Scheme (CPCSS) based on a cloud model and redundancy degree in sensor networks is proposed. Firstly, the normal cloud model is adopted for calculating the similarity degree between the sensor nodes in terms of their historical data, and then all nodes in each grid of the target area can be classified into several categories. Secondly, the redundancy degree of a node is calculated according to its sensing area being covered by the neighboring sensors. Finally, a centralized approximation algorithm based on the partition of the target area is designed to obtain the approximate minimum set of nodes, which can retain the sufficient coverage of the target region and ensure the connectivity of the network at the same time. The simulation results show that the proposed CPCSS can balance the energy consumption and optimize the coverage performance of the sensor network.
Evaluation of the Risk Factors for a Rotator Cuff Retear After Repair Surgery.
Lee, Yeong Seok; Jeong, Jeung Yeol; Park, Chan-Deok; Kang, Seung Gyoon; Yoo, Jae Chul
2017-07-01
A retear is a significant clinical problem after rotator cuff repair. However, no study has evaluated the retear rate with regard to the extent of footprint coverage. To evaluate the preoperative and intraoperative factors for a retear after rotator cuff repair, and to confirm the relationship with the extent of footprint coverage. Cohort study; Level of evidence, 3. Data were retrospectively collected from 693 patients who underwent arthroscopic rotator cuff repair between January 2006 and December 2014. All repairs were classified into 4 types of completeness of repair according to the amount of footprint coverage at the end of surgery. All patients underwent magnetic resonance imaging (MRI) after a mean postoperative duration of 5.4 months. Preoperative demographic data, functional scores, range of motion, and global fatty degeneration on preoperative MRI and intraoperative variables including the tear size, completeness of rotator cuff repair, concomitant subscapularis repair, number of suture anchors used, repair technique (single-row or transosseous-equivalent double-row repair), and surgical duration were evaluated. Furthermore, the factors associated with failure using the single-row technique and transosseous-equivalent double-row technique were analyzed separately. The retear rate was 7.22%. Univariate analysis revealed that rotator cuff retears were affected by age; the presence of inflammatory arthritis; the completeness of rotator cuff repair; the initial tear size; the number of suture anchors; mean operative time; functional visual analog scale scores; Simple Shoulder Test findings; American Shoulder and Elbow Surgeons scores; and fatty degeneration of the supraspinatus, infraspinatus, and subscapularis. Multivariate logistic regression analysis revealed patient age, initial tear size, and fatty degeneration of the supraspinatus as independent risk factors for a rotator cuff retear. Multivariate logistic regression analysis of the single-row group revealed patient age and fatty degeneration of the supraspinatus as independent risk factors for a rotator cuff retear. Multivariate logistic regression analysis of the transosseous-equivalent double-row group revealed a frozen shoulder as an independent risk factor for a rotator cuff retear. Our results suggest that patient age, initial tear size, and fatty degeneration of the supraspinatus are independent risk factors for a rotator cuff retear, whereas the completeness of rotator cuff repair based on the extent of footprint coverage and repair technique are not.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, I; Hossain, S; Algan, O
Purpose: To investigate quantitatively positioning and dosimetric uncertainties due to 4D-CT intra-phase motion in the internal-target-volume (ITV) associated with radiation therapy using respiratory-gating for patients setup with image-guidance-radiation-therapy (IGRT) using free-breathing or average-phase CT-images. Methods: A lung phantom with an embedded tissue-equivalent target is imaged with CT while it is stationary and moving. Four-sets of structures are outlined: (a) the actual target on CT-images of the stationary-target, (b) ITV on CT-images for the free-moving phantom, (c) ITV’s from the ten different phases (10–100%) and (d) ITV on the CT-images generated from combining 3 phases: 40%–50%–60%. The variations in volume, lengthmore » and center-position of the ITV’s and their effects on dosimetry during dose delivery for patients setup with image-guidance are investigated. Results: Intra-phase motion due to breathing affects the volume, center position and length of the ITVs from different respiratory-phases. The ITV’s vary by about 10% from one phase to another. The largest ITV is measured on the free breathing CT images and the smallest is on the stationary CT-images. The ITV lengths vary by about 4mm where it may shrink or elongated depending on the motion-phase. The center position of the ITV varies between the different motion-phases which shifts upto 10mm from the stationary-position which is nearly equal to motion-amplitude. This causes systematic shifts during dose delivery with beam gating using certain phases (40%–50%–60%) for patients setup with IGRT using free-breathing or average-phase CT-images. The dose coverage of the ITV depends on the margins used for treatment-planning-volume where margins larger than the motion-amplitudes are needed to ensure dose coverage of the ITV. Conclusion: Volume, length, and center position of the ITV’s change between the different motion phases. Large systematic shifts are induced by respiratory-gating with ITVs on certain phases when patients are setup with IGRT using free-breathing or average-phase CT-images.« less
Competitive Protein Adsorption on Polysaccharide and Hyaluronate Modified Surfaces
Ombelli, Michela; Costello, Lauren; Postle, Corinne; Anantharaman, Vinod; Meng, Qing Cheng; Composto, Russell J.; Eckmann, David M.
2011-01-01
We measured adsorption of bovine serum albumin (BSA) and fibrinogen (Fg) onto six distinct bare and dextran- and hyaluronate-modified silicon surfaces created using two dextran grafting densities and three hyaluronic acid (HA) sodium salts derived from human umbilical cord, rooster comb and streptococcus zooepidemicus. Film thickness and surface morphology depended on HA molecular weight and concentration. BSA coverage was enhanced on surfaces upon competitive adsorption of BSA:Fg mixtures. Dextranization differentially reduced protein adsorption onto surfaces based on oxidation state. Hyaluronization was demonstrated to provide the greatest resistance to protein coverage, equivalent to that of the most resistant dextranized surface. Resistance to protein adsorption was independent of the type of hyaluronic acid utilized. With changing bulk protein concentration from 20 to 40 µg ml−1 for each species, Fg coverage on silicon increased by 4×, whereas both BSA and Fg adsorption on dextran and HA were far less dependent of protein bulk concentration. PMID:21623481
Murthy, Kk; Shukeili, Ka; Kumar, Ss; Davis, Ca; Chandran, Rr; Namrata, S
2010-01-01
To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared. The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p<0.001) with higher conformity index value of 0.81±0.07 compared to both the 3D-CRT plans. The doses to the liver and bowel reduced significantly (p<0.001) with IMRT plans compared to other 3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans. This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment.
Liu, Zhong; Gao, Xiaoguang; Fu, Xiaowei
2018-05-08
In this paper, we mainly study a cooperative search and coverage algorithm for a given bounded rectangle region, which contains several unknown stationary targets, by a team of unmanned aerial vehicles (UAVs) with non-ideal sensors and limited communication ranges. Our goal is to minimize the search time, while gathering more information about the environment and finding more targets. For this purpose, a novel cooperative search and coverage algorithm with controllable revisit mechanism is presented. Firstly, as the representation of the environment, the cognitive maps that included the target probability map (TPM), the uncertain map (UM), and the digital pheromone map (DPM) are constituted. We also design a distributed update and fusion scheme for the cognitive map. This update and fusion scheme can guarantee that each one of the cognitive maps converges to the same one, which reflects the targets’ true existence or absence in each cell of the search region. Secondly, we develop a controllable revisit mechanism based on the DPM. This mechanism can concentrate the UAVs to revisit sub-areas that have a large target probability or high uncertainty. Thirdly, in the frame of distributed receding horizon optimizing, a path planning algorithm for the multi-UAVs cooperative search and coverage is designed. In the path planning algorithm, the movement of the UAVs is restricted by the potential fields to meet the requirements of avoiding collision and maintaining connectivity constraints. Moreover, using the minimum spanning tree (MST) topology optimization strategy, we can obtain a tradeoff between the search coverage enhancement and the connectivity maintenance. The feasibility of the proposed algorithm is demonstrated by comparison simulations by way of analyzing the effects of the controllable revisit mechanism and the connectivity maintenance scheme. The Monte Carlo method is employed to validate the influence of the number of UAVs, the sensing radius, the detection and false alarm probabilities, and the communication range on the proposed algorithm.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-04
... frame that is not necessarily a NEMA- equivalent but otherwise covered under EISA 2007) that is June 4.... Definition of NEMA Design B Motors E. Fire Pump Motors Definition F. Fire Pump Motor Coverage G. Energy... provisions designed to improve appliance and commercial equipment energy efficiency. (All references to EPCA...
VizieR Online Data Catalog: Ammonia observations in G79.29+0.46 (Rizzo+, 2014)
NASA Astrophysics Data System (ADS)
Rizzo, J. R.; Palau, A.; Jimenez-Esteban, F. M.; Henkel, C.
2014-01-01
For each transition, a total of 130 spectra is available. Each spectrum has 347 channels, and a velocity coverage from -40 to +40km/s, including all the hyperfine components. Frequency resolution is 183kHz, equivalent to a velocity resolution of 0.23km/s. (3 data files).
The Interplay between Text-Based Vocabulary Size and Reading Comprehension of Turkish EFL Learners
ERIC Educational Resources Information Center
Güngör, Fatih; Yayli, Demet
2016-01-01
Reading is an indispensable skill for learners who desire success throughout their academic lives, and vocabulary knowledge is a sine qua non companion of reading comprehension. Despite being inextricably related entities, very little has been written about the necessary vocabulary coverage to understand an expository text and its equivalent in…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-06
... the Retired Reserve who are qualified for non-regular retirement, but are not yet 60 years of age, to qualify to purchase medical coverage equivalent to the TRICARE Standard (and Extra) benefit unless that... Code. Section 1076e allows members of the Retired Reserve who are qualified for non-regular retirement...
Increasing influenza vaccination coverage in recommended population groups in Europe.
Blank, Patricia R; Szucs, Thomas D
2009-04-01
The clinical and economic burden of seasonal influenza is frequently underestimated. The cornerstone of controlling and preventing influenza is vaccination. National and international guidelines aim to implement immunization programs and targeted vaccination-coverage rates, which should help to enhance the vaccine uptake, especially in the at-risk population. This review purposes to highlight the vaccination guidelines and the actual vaccination situation in four target groups (the elderly, people with underlying chronic conditions, healthcare workers and children) from a European point of view.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, S; Depauw, N; Flanz, J
2016-06-15
Purpose: Gantry-less proton treatment facility could lower the capital cost of proton therapy. This study investigates the dosimetric feasibility of using only coplanar pencil beam scanning (PBS) beams for those patients who had beam angles that would not have been deliverable without the gantry. Those coplanar beams are implemented on gantry-less horizontal beam-line with patients in sitting or standing positions. Methods: We have selected ten patients (seven head-and-neck, one thoracic, one abdominal and one pelvic case) with clinically delivered double scattering (DS) or PBS treatment plans with beam angles that were challenging to achieve without a gantry. After removing thesemore » beams angles, PBS plans were optimized for gantry-less intensity modulated proton therapy (IMPT) or single field optimization (SFO) with multi-criteria optimization (MCO). For head-and-neck patients who were treated by DS, we generated PBS plans with non-coplanar beams for comparison. Dose-volume-histograms (DVHs), target homogeneity index (HI), mean dose, D-2 and D-98 were reported. Robustness analysis was performed with ±2.5 mm setup errors and ±3.5% range uncertainties for three head-and-neck patients. Results: PBS-gantry-less plans provided more homogenous target coverage and significant improvements on organs-at-risk (OARs) sparing, compared to passive scattering treatments with a gantry. The PBS gantry-less treatments reduced the HI for target coverage by 1.3% to 47.2%, except for a suprasellar patient and a liver patient. The PBS-gantry-less plans reduced the D-mean of OARs by 3.6% to 67.4%. The PBS-gantry plans had similar target coverage and only marginal improvements on OAR sparing as compared to the PBS-gantry-less plans. These two PBS plans also had similar robustness relative to range uncertainties and setup errors. Conclusion: The gantry-less plans have with less mean dose to OARs and more homogeneous target coverage. Although the PBS-gantry plans have slightly improved target coverage and OARs sparing, the overall benefit of having a gantry to provide non-coplanar beams is debatable.« less
Measles and Rubella Global Strategic Plan 2012-2020 midterm review.
Orenstein, W A; Hinman, A; Nkowane, B; Olive, J M; Reingold, A
2018-01-11
1. Measles eradication is the ultimate goal but it is premature to set a date for its accomplishment. Existing regional elimination goals should be vigorously pursued to enable setting a global target by 2020. 2. The basic strategic approaches articulated in the Global Measles and Rubella Strategic Plan 2012-2020 are valid to achieve the goals but have not been fully implemented (or not appropriately adapted to local situations). 3. The report recommends a shift from primary reliance on supplementary immunization activities (SIAs) to assure two doses of measles-containing vaccine (MCV) are delivered to the target population to primary reliance on ongoing services to assure administration of two doses of MCV. Regular high quality SIAs will still be necessary while ongoing services are being strengthened. 4. The report recommends a shift from primary reliance on coverage to measure progress to incorporating disease incidence as a major indicator. 5. The report recommends that the measles/rubella vaccination program be considered an indicator for the quality of the overall immunization program and that measles/rubella incidence and measles and rubella vaccination coverage be considered as primary indicators of immunization program performance. 6. Polio transition presents both risks and opportunities: risks should be minimized and opportunities maximized. 7. A school entry immunization check could contribute significantly to strengthening overall immunization services with assurance that recommended doses of measles and rubella vaccines as well as other vaccines have been delivered and providing those vaccines at that time if the child is un- or under-vaccinated. 8. Program decisions should increasingly be based on good quality data and appropriate analysis. 9. The incorporation of rubella vaccination into the immunization program needs to be accelerated - it should be accorded equivalent emphasis as measles. 10. Outbreak investigation and response are critical but the most important thing is to prevent outbreaks. Copyright © 2017 World Health Organization. Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moteabbed, M; Depauw, N; Kooy, H
Purpose: To investigate the dosimetric benefits of pencil beam scanning (PBS) compared with passive scattered (PS) proton therapy for treatment of pediatric head&neck patients as a function of the PBS spot size and explore the advantages of using apertures in PBS. Methods: Ten pediatric patients with head&neck cancers treated by PS proton therapy at our institution were retrospectively selected. The histologies included rhabdomyosarcoma, ependymoma, astrocytoma, craniopharyngioma and germinoma. The prescribed dose ranged from 36 to 54 Gy(RBE). Five PBS plans were created for each patient using variable spot size (average sigma at isocenter) and choice of beam specific apertures: (1)more » 10mm spots, (2) 10mm spots with apertures, (3) 6mm spots, (4) 6mm spots with apertures, and (5) 3mm spots. The plans were optimized for intensity modulated proton therapy (IMPT) with no single beam uniformity constraints. Dose volume indices as well as equivalent uniform dose (EUD) were compared between PS and PBS plans. Results: Although target coverage was clinically adequate for all cases, the plans with largest (10mm) spots provide inferior quality compared with PS in terms of dose to organs-at-risk (OAR). However, adding apertures to these plans ensured lower OAR dose than PS. The average EUD difference between PBS and PS plans over all patients and organs at risk were (1) 2.5%, (2) −5.1%, (3) -5%, (4) −7.8%, and (5) −9.5%. As the spot size decreased, more conformal plans were achieved that offered similar target coverage but lower dose to the neighboring healthy organs, while alleviating the need for using apertures. Conclusion: The application of PBS does not always translate to better plan qualities compared to PS depending on the available beam spot size. We recommend that institutions with spot size larger than ∼6mm at isocenter consider using apertures to guarantee clinically comparable or superior dosimetric efficacy to PS treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cotter, Shane E.; Herrup, David A.; Friedmann, Alison
Purpose: In this study, we report the clinical outcomes of 7 children with bladder/prostate rhabdomyosarcoma (RMS) treated with proton radiation and compare proton treatment plans with matched intensity-modulated radiation therapy (IMRT) plans, with an emphasis on dose savings to reproductive and skeletal structures. Methods and Materials: Follow-up consisted of scheduled clinic appointments at our institution or direct communication with the treating physicians for referred patients. Each proton radiotherapy plan used for treatment was directly compared to an IMRT plan generated for the study. Clinical target volumes and normal tissue volumes were held constant to facilitate dosimetric comparisons. Each plan wasmore » optimized for target coverage and normal tissue sparing. Results: Seven male patients were treated with proton radiotherapy for bladder/prostate RMS at the Massachusetts General Hospital between 2002 and 2008. Median age at treatment was 30 months (11-70 months). Median follow-up was 27 months (10-90 months). Four patients underwent a gross total resection prior to radiation, and all patients received concurrent chemotherapy. Radiation doses ranged from 36 cobalt Gray equivalent (CGE) to 50.4 CGE. Five of 7 patients were without evidence of disease and with intact bladders at study completion. Target volume dosimetry was equivalent between the two modalities for all 7 patients. Proton radiotherapy led to a significant decrease in mean organ dose to the bladder (25.1 CGE vs. 33.2 Gy; p = 0.03), testes (0.0 CGE vs. 0.6 Gy; p = 0.016), femoral heads (1.6 CGE vs. 10.6 Gy; p = 0.016), growth plates (21.7 CGE vs. 32.4 Gy; p = 0.016), and pelvic bones (8.8 CGE vs. 13.5 Gy; p = 0.016) compared to IMRT. Conclusions: This study provides evidence of significant dose savings to normal structures with proton radiotherapy compared to IMRT and is well tolerated in this patient population. The long-term impact of these reduced doses can be tested in future studies incorporating extended follow-up, objective outcome measures, and quality-of-life analyses.« less
WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsang, H; Kamerling, CP; Ziegenhein, P
2016-06-15
Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reducedmore » OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quirk, S; Conroy, L; Smith, WL
Partial breast irradiation (PBI) following breast-conserving surgery is emerging as an effective means to achieve local control and reduce irradiated breast volume. Patients are planned on a static CT image; however, treatment is delivered while the patient is free-breathing. Respiratory motion can degrade plan quality by reducing target coverage and/or dose homogeneity. A variety of methods can be used to determine the required margin for respiratory motion in PBI. We derive geometric and dosimetric respiratory 1D margin. We also verify the adequacy of the typical 5 mm respiratory margin in 3D by evaluating plan quality for increasing respiratory amplitudes (2–20more » mm). Ten PBI plans were used for dosimetric evaluation. A database of volunteer respiratory data, with similar characteristics to breast cancer patients, was used for this study. We derived a geometric 95%-margin of 3 mm from the population respiratory data. We derived a dosimetric 95%-margin of 2 mm by convolving 1D dose profiles with respiratory probability density functions. The 5 mm respiratory margin is possibly too large when 1D coverage is assessed and could lead to unnecessary normal tissue irradiation. Assessing margins only for coverage may be insufficient; 3D dosimetric assessment revealed degradation in dose homogeneity is the limiting factor, not target coverage. Hotspots increased even for the smallest respiratory amplitudes, while target coverage only degraded at amplitudes greater than 10 mm. The 5 mm respiratory margin is adequate for coverage, but due to plan quality degradation, respiratory management is recommended for patients with respiratory amplitudes greater than 10 mm.« less
McGuire, Michael K; Scheyer, E Todd
2010-08-01
For root coverage therapy, the connective tissue graft (CTG) plus coronally advanced flap (CAF) is considered the gold standard therapy against which alternative therapies are generally compared. When evaluating these therapies, in addition to traditional measures of root coverage, subject-reported, qualitative measures of esthetics, pain, and overall preferences for alternative procedures should also be considered. This study determines if a xenogeneic collagen matrix (CM) with CAF might be as effective as CTG+CAF in the treatment of recession defects. This study was a single-masked, randomized, controlled, split-mouth study of dehiscence-type recession defects in contralateral sites; one defect received CTG+CAF and the other defect received CM+CAF. A total of 25 subjects (8 male, 17 female; mean age: 43.7 +/- 12.2 years) were evaluated at 6 months and 1 year. The primary efficacy endpoint was recession depth at 6 months. Secondary endpoints included traditional periodontal measures, such as width of keratinized tissue and percentage of root coverage. Subject-reported values of pain, discomfort, and esthetic satisfaction were also recorded. At 6 months, recession depth was on average 0.52 mm for test sites and 0.10 mm for control sites. Recession depth change from baseline was statistically significant between test and control, with an average of 2.62 mm gained at test sites and 3.10 mm gained at control sites for a difference of 0.4 mm (P = 0.0062). At 1 year, test percentage of root coverage averaged 88.5%, and controls averaged 99.3% (P = 0.0313). Keratinized tissue width gains were equivalent for both therapies and averaged 1.34 mm for test sites and 1.26 mm for control sites (P = 0.9061). There were no statistically significant differences between subject-reported values for esthetic satisfaction, and subjects' assessments of pain and discomfort were also equivalent. When balanced with subject-reported esthetic values and compared to historical root coverage outcomes reported by other investigators, CM+CAF presents a viable alternative to CTG+CAF, without the morbidity of soft tissue graft harvest.
Financial incentives to encourage healthy behaviour: an analysis of U.K. media coverage.
Parke, Hannah; Ashcroft, Richard; Brown, Rebecca; Marteau, Theresa M; Seale, Clive
2013-09-01
Policies to use financial incentives to encourage healthy behaviour are controversial. Much of this controversy is played out in the mass media, both reflecting and shaping public opinion. To describe U.K. mass media coverage of incentive schemes, comparing schemes targeted at different client groups and assessing the relative prominence of the views of different interest groups. Thematic content analysis. National and local news coverage in newspapers, news media targeted at health-care providers and popular websites between January 2005 and February 2010. U.K. mass media. The study included 210 articles. Fifteen separate arguments favourable towards schemes, and 19 unfavourable, were identified. Overall, coverage was more favourable than unfavourable, although most articles reported a mix of views. Arguments about the prevalence and seriousness of the health problems targeted by incentive schemes were uncontested. Moral and ethical objections to such schemes were common, focused in particular on recipients such as drug users or the overweight who were already stereotyped as morally deficient, and these arguments were largely uncontested. Arguments about the effectiveness of schemes and their potential for benefit or harm were areas of greater contestation. Government, public health and other health-care provider interests dominated favourable coverage; opposition came from rival politicians, taxpayers' representatives, certain charities and from some journalists themselves. Those promoting incentive schemes for people who might be regarded as 'undeserving' should plan a media strategy that anticipates their public reception. © 2011 John Wiley & Sons Ltd.
Financial incentives to encourage healthy behaviour: an analysis of UK media coverage
Parke, Hannah; Ashcroft, Richard; Brown, Rebecca; Marteau, Theresa M; Seale, Clive
2011-01-01
Abstract Background Policies to use financial incentives to encourage healthy behaviour are controversial. Much of this controversy is played out in the mass media, both reflecting and shaping public opinion. Objective To describe UK mass media coverage of incentive schemes, comparing schemes targeted at different client groups and assessing the relative prominence of the views of different interest groups. Design Thematic content analysis. Subjects National and local news coverage in newspapers, news media targeted at health‐care providers and popular websites between January 2005 and February 2010. Setting UK mass media. Results The study included 210 articles. Fifteen separate arguments favourable towards schemes, and 19 unfavourable, were identified. Overall, coverage was more favourable than unfavourable, although most articles reported a mix of views. Arguments about the prevalence and seriousness of the health problems targeted by incentive schemes were uncontested. Moral and ethical objections to such schemes were common, focused in particular on recipients such as drug users or the overweight who were already stereotyped as morally deficient, and these arguments were largely uncontested. Arguments about the effectiveness of schemes and their potential for benefit or harm were areas of greater contestation. Government, public health and other health‐care provider interests dominated favourable coverage; opposition came from rival politicians, taxpayers’ representatives, certain charities and from some journalists themselves. Conclusions Those promoting incentive schemes for people who might be regarded as ‘undeserving’ should plan a media strategy that anticipates their public reception. PMID:21771227
Gerlier, Laetitia; Lamotte, Mark; Dos Santos Mendes, Sofia; Damm, Oliver; Schwehm, Markus; Eichner, Martin
2016-08-01
Our objectives were to estimate the public health outcomes of vaccinating Belgian children using an intranasal tetravalent live-attenuated influenza vaccine (QLAIV) combined with current coverage of high-risk/elderly individuals using the trivalent inactivated vaccine. We used a deterministic, age-structured, dynamic model to simulate seasonal influenza transmission in the Belgian population under the current coverage or after extending vaccination with QLAIV to healthy children aged 2-17 years. Differential equations describe demographic changes, exposure to infectious individuals, infection recovery, and immunity dynamics. The basic reproduction number (R 0) was calibrated to the observed number of influenza doctor visits/year. Vaccine efficacy was 80 % (live-attenuated) and 59-68 % (inactivated). The 10-year incidence of symptomatic influenza was calculated with different coverage scenarios (add-on to current coverage). Model calibration yielded R 0 = 1.1. QLAIV coverage of 75 % of those aged 2-17 years averted 374,000 symptomatic cases/year (57 % of the current number), 244,000 of which were among adults (indirect effect). Vaccinating 75 % of those aged 2-11 years and 50 % of those aged 12-17 years averted 333,200 cases/year (213,000 adult cases/year). Vaccinating only healthy children aged 2-5 years generated direct protection but limited indirect protection, even with 90 % coverage (40,800 averted adult cases/year; -8.4 %). Targeting all children averted twice as many high-risk cases as targeting high-risk children only (8485 vs. 4965/year with 75 % coverage). Sensitivity analyses showed the robustness of results. The model highlights the direct and indirect protection benefits when vaccinating healthy children with QLAIV in Belgium. Policies targeting only high-risk individuals or the youngest provide limited herd protection, as school-age children are important influenza vectors in the community.
Yock, Adam D; Kim, Gwe-Ya
2017-09-01
To present the k-means clustering algorithm as a tool to address treatment planning considerations characteristic of stereotactic radiosurgery using a single isocenter for multiple targets. For 30 patients treated with stereotactic radiosurgery for multiple brain metastases, the geometric centroids and radii of each met were determined from the treatment planning system. In-house software used this as well as weighted and unweighted versions of the k-means clustering algorithm to group the targets to be treated with a single isocenter, and to position each isocenter. The algorithm results were evaluated using within-cluster sum of squares as well as a minimum target coverage metric that considered the effect of target size. Both versions of the algorithm were applied to an example patient to demonstrate the prospective determination of the appropriate number and location of isocenters. Both weighted and unweighted versions of the k-means algorithm were applied successfully to determine the number and position of isocenters. Comparing the two, both the within-cluster sum of squares metric and the minimum target coverage metric resulting from the unweighted version were less than those from the weighted version. The average magnitudes of the differences were small (-0.2 cm 2 and 0.1% for the within cluster sum of squares and minimum target coverage, respectively) but statistically significant (Wilcoxon signed-rank test, P < 0.01). The differences between the versions of the k-means clustering algorithm represented an advantage of the unweighted version for the within-cluster sum of squares metric, and an advantage of the weighted version for the minimum target coverage metric. While additional treatment planning considerations have a large influence on the final treatment plan quality, both versions of the k-means algorithm provide automatic, consistent, quantitative, and objective solutions to the tasks associated with SRS treatment planning using a single isocenter for multiple targets. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Is universal health coverage the practical expression of the right to health care?
2014-01-01
The present Millennium Development Goals are set to expire in 2015 and their next iteration is now being discussed within the international community. With regards to health, the World Health Organization proposes universal health coverage as a ‘single overarching health goal’ for the next iteration of the Millennium Development Goals. The present Millennium Development Goals have been criticised for being ‘duplicative’ or even ‘competing alternatives’ to international human rights law. The question then arises, if universal health coverage would indeed become the single overarching health goal, replacing the present health-related Millennium Development Goals, would that be more consistent with the right to health? The World Health Organization seems to have anticipated the question, as it labels universal health coverage as “by definition, a practical expression of the concern for health equity and the right to health”. Rather than waiting for the negotiations to unfold, we thought it would be useful to verify this contention, using a comparative normative analysis. We found that – to be a practical expression of the right to health – at least one element is missing in present authoritative definitions of universal health coverage: a straightforward confirmation that international assistance is essential, not optional. But universal health coverage is a ‘work in progress’. A recent proposal by the United Nations Sustainable Development Solutions Network proposed universal health coverage with a set of targets, including a target for international assistance, which would turn universal health coverage into a practical expression of the right to health care. PMID:24559232
The web and public confidence in MMR vaccination in Italy.
Aquino, Francesco; Donzelli, Gabriele; De Franco, Emanuela; Privitera, Gaetano; Lopalco, Pier Luigi; Carducci, Annalaura
2017-08-16
Measles, mumps and rubella (MMR) vaccination coverage in Italy has been decreasing starting from 2012 and, at the present, none of the Italian regions has achieved the goal of 95% coverage target. A decision of the Court of Justice of Rimini in March 2012 that awarded vaccine-injury compensation for a case of autism has been indicated as a probable trigger event leading to a reduction of vaccine confidence in Italy. The aim of the study was to explore the relationship between MMR vaccination coverage to online search trends and social network activity on the topic "autism and MMR vaccine", during the period 2010-2015. A significant inverse correlation was found between MMR vaccination coverage and Internet search activity, tweets and Facebook posts. New media might have played a role in spreading misinformation. Media monitoring could be useful to assess the level of vaccine hesitancy and to plan and target effective information campaigns. Copyright © 2017 Elsevier Ltd. All rights reserved.
Han, Jijun; Yang, Deqiang; Sun, Houjun; Xin, Sherman Xuegang
2017-01-01
Inverse method is inherently suitable for calculating the distribution of source current density related with an irregularly structured electromagnetic target field. However, the present form of inverse method cannot calculate complex field-tissue interactions. A novel hybrid inverse/finite-difference time domain (FDTD) method that can calculate the complex field-tissue interactions for the inverse design of source current density related with an irregularly structured electromagnetic target field is proposed. A Huygens' equivalent surface is established as a bridge to combine the inverse and FDTD method. Distribution of the radiofrequency (RF) magnetic field on the Huygens' equivalent surface is obtained using the FDTD method by considering the complex field-tissue interactions within the human body model. The obtained magnetic field distributed on the Huygens' equivalent surface is regarded as the next target. The current density on the designated source surface is derived using the inverse method. The homogeneity of target magnetic field and specific energy absorption rate are calculated to verify the proposed method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, Jeff, E-mail: jmeye3@utsouthwestern.ed; Bluett, Jaques; Amos, Richard
Purpose: Conventional proton therapy with passively scattered beams is used to treat a number of tumor sites, including prostate cancer. Spot scanning proton therapy is a treatment delivery means that improves conformal coverage of the clinical target volume (CTV). Placement of individual spots within a target is dependent on traversed tissue density. Errors in patient alignment perturb dose distributions. Moreover, there is a need for a rational planning approach that can mitigate the dosimetric effect of random alignment errors. We propose a treatment planning approach and then analyze the consequences of various simulated alignment errors on prostate treatments. Methods andmore » Materials: Ten control patients with localized prostate cancer underwent treatment planning for spot scanning proton therapy. After delineation of the clinical target volume, a scanning target volume (STV) was created to guide dose coverage. Errors in patient alignment in two axes (rotational and yaw) as well as translational errors in the anteroposterior direction were then simulated, and dose to the CTV and normal tissues were reanalyzed. Results: Coverage of the CTV remained high even in the setting of extreme rotational and yaw misalignments. Changes in the rectum and bladder V45 and V70 were similarly minimal, except in the case of translational errors, where, as a result of opposed lateral beam arrangements, much larger dosimetric perturbations were observed. Conclusions: The concept of the STV as applied to spot scanning radiation therapy and as presented in this report leads to robust coverage of the CTV even in the setting of extreme patient misalignments.« less
Osei, Ernest; Barnett, Rob
2015-01-01
The aim of this study is to provide guidelines for the selection of external‐beam radiation therapy target margins to compensate for target motion in the lung during treatment planning. A convolution model was employed to predict the effect of target motion on the delivered dose distribution. The accuracy of the model was confirmed with radiochromic film measurements in both static and dynamic phantom modes. 502 unique patient breathing traces were recorded and used to simulate the effect of target motion on a dose distribution. A 1D probability density function (PDF) representing the position of the target throughout the breathing cycle was generated from each breathing trace obtained during 4D CT. Changes in the target D95 (the minimum dose received by 95% of the treatment target) due to target motion were analyzed and shown to correlate with the standard deviation of the PDF. Furthermore, the amount of target D95 recovered per millimeter of increased field width was also shown to correlate with the standard deviation of the PDF. The sensitivity of changes in dose coverage with respect to target size was also determined. Margin selection recommendations that can be used to compensate for loss of target D95 were generated based on the simulation results. These results are discussed in the context of clinical plans. We conclude that, for PDF standard deviations less than 0.4 cm with target sizes greater than 5 cm, little or no additional margins are required. Targets which are smaller than 5 cm with PDF standard deviations larger than 0.4 cm are most susceptible to loss of coverage. The largest additional required margin in this study was determined to be 8 mm. PACS numbers: 87.53.Bn, 87.53.Kn, 87.55.D‐, 87.55.Gh
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prokic, Vesna, E-mail: vesna.prokic@uniklinik-freiburg.de; Wiedenmann, Nicole; Fels, Franziska
2013-01-01
Purpose: To develop a new treatment planning strategy in patients with multiple brain metastases. The goal was to perform whole brain irradiation (WBI) with hippocampal sparing and dose escalation on multiple brain metastases. Two treatment concepts were investigated: simultaneously integrated boost (SIB) and WBI followed by stereotactic fractionated radiation therapy sequential concept (SC). Methods and Materials: Treatment plans for both concepts were calculated for 10 patients with 2-8 brain metastases using volumetric modulated arc therapy. In the SIB concept, the prescribed dose was 30 Gy in 12 fractions to the whole brain and 51 Gy in 12 fractions to individualmore » brain metastases. In the SC concept, the prescription was 30 Gy in 12 fractions to the whole brain followed by 18 Gy in 2 fractions to brain metastases. All plans were optimized for dose coverage of whole brain and lesions, simultaneously minimizing dose to the hippocampus. The treatment plans were evaluated on target coverage, homogeneity, and minimal dose to the hippocampus and organs at risk. Results: The SIB concept enabled more successful sparing of the hippocampus; the mean dose to the hippocampus was 7.55 {+-} 0.62 Gy and 6.29 {+-} 0.62 Gy, respectively, when 5-mm and 10-mm avoidance regions around the hippocampus were used, normalized to 2-Gy fractions. In the SC concept, the mean dose to hippocampus was 9.8 {+-} 1.75 Gy. The mean dose to the whole brain (excluding metastases) was 33.2 {+-} 0.7 Gy and 32.7 {+-} 0.96 Gy, respectively, in the SIB concept, for 5-mm and 10-mm hippocampus avoidance regions, and 37.23 {+-} 1.42 Gy in SC. Conclusions: Both concepts, SIB and SC, were able to achieve adequate whole brain coverage and radiosurgery-equivalent dose distributions to individual brain metastases. The SIB technique achieved better sparing of the hippocampus, especially when a10-mm hippocampal avoidance region was used.« less
Kripke, Katharine; Samuelson, Julia; Schnure, Melissa; Dalal, Shona; Farley, Timothy; Hankins, Catherine; Thomas, Anne G.; Reed, Jason; Stegman, Peter; Bock, Naomi
2016-01-01
Background In 2007, the World Health Organization and the Joint United Nations Programme on HIV/AIDS (UNAIDS) identified 14 priority countries across eastern and southern Africa for scaling up voluntary medical male circumcision (VMMC) services. Several years into this effort, we reflect on progress. Methods Using the Decision Makers’ Program Planning Tool (DMPPT) 2.1, we assessed age-specific impact, cost-effectiveness, and coverage attributable to circumcisions performed through 2014. We also compared impact of actual progress to that of achieving 80% coverage among men ages 15–49 in 12 VMMC priority countries and Nyanza Province, Kenya. We populated the models with age-disaggregated VMMC service statistics and with population, mortality, and HIV incidence and prevalence projections exported from country-specific Spectrum/Goals files. We assumed each country achieved UNAIDS’ 90-90-90 treatment targets. Results More than 9 million VMMCs were conducted through 2014: 43% of the estimated 20.9 million VMMCs required to reach 80% coverage by the end of 2015. The model assumed each country reaches the UNAIDS targets, and projected that VMMCs conducted through 2014 will avert 240,000 infections by the end of 2025, compared to 1.1 million if each country had reached 80% coverage by the end of 2015. The median estimated cost per HIV infection averted was $4,400. Nyanza Province in Kenya, the 11 priority regions in Tanzania, and Uganda have reached or are approaching MC coverage targets among males ages 15–24, while coverage in other age groups is lower. Across all countries modeled, more than half of the projected HIV infections averted were attributable to circumcising 10- to 19-year-olds. Conclusions The priority countries have made considerable progress in VMMC scale-up, and VMMC remains a cost-effective strategy for epidemic impact, even assuming near-universal HIV diagnosis, treatment coverage, and viral suppression. Examining circumcision coverage by five-year age groups will inform countries’ decisions about next steps. PMID:27441648
The 5As: A practical taxonomy for the determinants of vaccine uptake.
Thomson, Angus; Robinson, Karis; Vallée-Tourangeau, Gaëlle
2016-02-17
Suboptimal vaccine uptake in both childhood and adult immunisation programs limits their full potential impact on global health. A recent progress review of the Global Vaccine Action Plan stated that "countries should urgently identify barriers and bottlenecks and implement targeted approaches to increase and sustain coverage". However, vaccination coverage may be determined by a complex mix of demographic, structural, social and behavioral factors. To develop a practical taxonomy to organise the myriad possible root causes of a gap in vaccination coverage rates, we performed a narrative review of the literature and tested whether all non-socio-demographic determinants of coverage could be organised into 4 dimensions: Access, Affordability, Awareness and Acceptance. Forty-three studies were reviewed, from which we identified 23 primary determinants of vaccination uptake. We identified a fifth domain, Activation, which captured interventions such as SMS reminders which effectively nudge people towards getting vaccinated. The 5As taxonomy captured all identified determinants of vaccine uptake. This intuitive taxonomy has already facilitated mutual understanding of the primary determinants of suboptimal coverage within inter-sectorial working groups, a first step towards them developing targeted and effective solutions. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
de Figueiredo, Alexandre; Johnston, Iain G; Smith, David M D; Agarwal, Sumeet; Larson, Heidi J; Jones, Nick S
2016-10-01
Incomplete immunisation coverage causes preventable illness and death in both developing and developed countries. Identification of factors that might modulate coverage could inform effective immunisation programmes and policies. We constructed a performance indicator that could quantitatively approximate measures of the susceptibility of immunisation programmes to coverage losses, with an aim to identify correlations between trends in vaccine coverage and socioeconomic factors. We undertook a data-driven time-series analysis to examine trends in coverage of diphtheria, tetanus, and pertussis (DTP) vaccination across 190 countries over the past 30 years. We grouped countries into six world regions according to WHO classifications. We used Gaussian process regression to forecast future coverage rates and provide a vaccine performance index: a summary measure of the strength of immunisation coverage in a country. Overall vaccine coverage increased in all six world regions between 1980 and 2010, with variation in volatility and trends. Our vaccine performance index identified that 53 countries had more than a 50% chance of missing the Global Vaccine Action Plan (GVAP) target of 90% worldwide coverage with three doses of DTP (DTP3) by 2015. These countries were mostly in sub-Saharan Africa and south Asia, but Austria and Ukraine also featured. Factors associated with DTP3 immunisation coverage varied by world region: personal income (Spearman's ρ=0·66, p=0·0011) and government health spending (0·66, p<0·0001) were informative of immunisation coverage in the Eastern Mediterranean between 1980 and 2010, whereas primary school completion was informative of coverage in Africa (0·56, p<0·0001) over the same period. The proportion of births attended by skilled health staff correlated significantly with immunisation coverage across many world regions. Our vaccine performance index highlighted countries at risk of failing to achieve the GVAP target of 90% coverage by 2015, and could aid policy makers' assessments of the strength and resilience of immunisation programmes. Weakening correlations with socioeconomic factors show a need to tackle vaccine confidence, whereas strengthening correlations point to clear factors to address. UK Engineering and Physical Sciences Research Council. Copyright © 2016 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.
The equivalent depth of burst for impact cratering
NASA Technical Reports Server (NTRS)
Holsapple, K. A.
1980-01-01
The concept of modeling an impact cratering event with an explosive event with the explosive buried at some equivalent depth of burst (d.o.b.) is discussed. Various and different ways to define this equivalent d.o.b. are identified. Recent experimental results for a dense quartz sand are used to determine the equivalent d.o.b. for various conditions of charge type, event size, and impact conditions. The results show a decrease in equivalent d.o.b. with increasing energy for fixed impact velocity and a decrease in equivalent d.o.b. with increasing velocity for fixed energy. The values for an iron projectile are on the order of 2-3 projectile radii for energy equal to one ton of TNT, decreasing to about 1.5 radii at a megaton of TNT. The dependence on projectile and target mass density matches that included in common jet-penetration formulas for projectile densities greater than target densities and for the higher energies.
A first vascularized skin equivalent as an alternative to animal experimentation.
Groeber, Florian; Engelhardt, Lisa; Lange, Julia; Kurdyn, Szymon; Schmid, Freia F; Rücker, Christoph; Mielke, Stephan; Walles, Heike; Hansmann, Jan
2016-01-01
Tissue-engineered skin equivalents mimic key aspects of the human skin, and can thus be employed as wound coverage for large skin defects or as in vitro test systems as an alternative to animal models. However, current skin equivalents lack a functional vasculature limiting clinical and research applications. This study demonstrates the generation of a vascularized skin equivalent with a perfused vascular network by combining a biological vascularized scaffold (BioVaSc) based on a decellularized segment of a porcine jejunum and a tailored bioreactor system. Briefly, the BioVaSc was seeded with human fibroblasts, keratinocytes, and human microvascular endothelial cells. After 14 days at the air-liquid interface, hematoxylin & eosin and immunohistological staining revealed a specific histological architecture representative of the human dermis and epidermis including a papillary-like architecture at the dermal-epidermal-junction. The formation of the skin barrier was measured non-destructively using impedance spectroscopy. Additionally, endothelial cells lined the walls of the formed vessels that could be perfused with a physiological volume flow. Due to the presence of a complex in-vivo-like vasculature, the here shown skin equivalent has the potential for skin grafting and represents a sophisticated in vitro model for dermatological research.
The role of helical tomotherapy in the treatment of bone plasmacytoma.
Chargari, Cyrus; Hijal, Tarek; Bouscary, Didier; Caussa, Lucas; Dendale, Remi; Zefkili, Sofia; Fourquet, Alain; Kirova, Youlia M
2012-01-01
We evaluated the early clinical outcome of patients with solitary bone plasmacytoma (SP) or a solitary lesion of multiple myeloma (MM) treated with helical tomotherapy (HT) compared with 3D conformal radiotherapy (3D-CRT), in terms of target coverage and exposure of critical organs. Ten patients with SP and 3 patients with a solitary lesion of MM underwent radiation therapy (RT) delivered by HT, to a dose of 40 Gy in 20 fractions. Treatment planning was then performed with 3D-CRT and the dosimetric parameters of both techniques were compared. Patients were also assessed for response to treatment and acute toxicities. With a median follow-up of 13 months, 78% of patients with pain before RT had resolution of their symptoms. Coverage of target lesion was adequate with both techniques in 12 of 13 patients. Target coverage was significantly lower for HT (V(95%) = 98.55% vs. 97.15%; p = 0.04, for 3D-CRT and HT, respectively). Target overdoses were also lower with HT (V(105%) = 2.01% vs. 0.19%; p= 0.16), although nonsignificant. Finally, there were no significant differences in organs-at-risk irradiation between both techniques. The early treatment tolerance was excellent, with no toxicity higher than grade I. RT of SP and MM with a solitary lesion can be safely delivered with HT, with no major acute side effects and good symptomatic control. Finally, HT provides a dosimetry similar to that of 3D-CRT in terms of organs-at-risk sparing and target volume coverage. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pham, Daniel, E-mail: Daniel.Pham@petermac.org; Kron, Tomas; Foroudi, Farshad
2013-10-01
Stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) targets requires motion management strategies to verify dose delivery. This case study highlights the effect of a change in patient breathing amplitude on the dosimetry to organs at risk and target structures. A 73-year-old male patient was planned for receiving 26 Gy of radiation in 1 fraction of SABR for a left primary RCC. The patient was simulated with four-dimensional computed tomography (4DCT) and the tumor internal target volume (ITV) was delineated using the 4DCT maximum intensity projection. However, the initially planned treatment was abandoned at the radiation oncologist'smore » discretion after pretreatment cone-beam CT (CBCT) motion verification identified a greater than 50% reduction in superior to inferior diaphragm motion as compared with the planning 4DCT. This patient was resimulated with respiratory coaching instructions. To assess the effect of the change in breathing on the dosimetry to the target, each plan was recalculated on the data set representing the change in breathing condition. A change from smaller to larger breathing showed a 46% loss in planning target volume (PTV) coverage, whereas a change from larger breathing to smaller breathing resulted in an 8% decrease in PTV coverage. ITV coverage was similarly reduced by 8% in both scenarios. This case study highlights the importance of tools to verify breathing motion prior to treatment delivery. 4D image guided radiation therapy verification strategies should focus on not only verifying ITV margin coverage but also the effect on the surrounding organs at risk.« less
Changes in Cirrus Cloudiness and their Relationship to Contrails
NASA Technical Reports Server (NTRS)
Minnis, Patrick; Ayers, J. Kirk; Palikonda, Rabindra; Doelling, David R.; Schumann, Ulrich; Gierens, Klaus
2001-01-01
Condensation trails, or contrails, formed in the wake of high-altitude aircraft have long been suspected of causing the formation of additional cirrus cloud cover. More cirrus is possible because 10 - 20% of the atmosphere at typical commercial flight altitudes is clear but ice-saturated. Since they can affect the radiation budget like natural cirrus clouds of equivalent optical depth and microphysical properties, contrail -generated cirrus clouds are another potential source of anthropogenic influence on climate. Initial estimates of contrail radiative forcing (CRF) were based on linear contrail coverage and optical depths derived from a limited number of satellite observations. Assuming that such estimates are accurate, they can be considered as the minimum possible CRF because contrails often develop into cirrus clouds unrecognizable as contrails. These anthropogenic cirrus are not likely to be identified as contrails from satellites and would, therefore, not contribute to estimates of contrail coverage. The mean lifetime and coverage of spreading contrails relative to linear contrails are needed to fully assess the climatic effect of contrails, but are difficult to measure directly. However, the maximum possible impact can be estimated using the relative trends in cirrus coverage over regions with and without air traffic. In this paper, the upper bound of CRF is derived by first computing the change in cirrus coverage over areas with heavy air traffic relative to that over the remainder of the globe assuming that the difference between the two trends is due solely to contrails. This difference is normalized to the corresponding linear contrail coverage for the same regions to obtain an average spreading factor. The maximum contrail-cirrus coverage, estimated as the product of the spreading factor and the linear contrail coverage, is then used in the radiative model to estimate the maximum potential CRF for current air traffic.
Strand, Kirsten Bjerkreim; Fekadu, Abebaw; Chisholm, Dan
2017-01-01
Abstract Background: Mental and neurological (MN) health care has long been neglected in low-income settings. This paper estimates health and non-health impacts of fully publicly financed care for selected key interventions in the National Mental Health Strategy in Ethiopia for depression, bipolar disorder, schizophrenia and epilepsy. Methods: A methodology of extended cost-effectiveness analysis (ECEA) is applied to MN health care in Ethiopia. The impact of providing a package of selected MN interventions free of charge in Ethiopia is estimated for: epilepsy (75% coverage, phenobarbital), depression (30% coverage, fluoxetine, cognitive therapy and proactive case management), bipolar affective disorder (50% coverage, valproate and psychosocial therapy) and schizophrenia (75% coverage, haloperidol plus psychosocial treatment). Multiple outcomes are estimated and disaggregated across wealth quintiles: (1) healthy-life-years (HALYs) gained; (2) household out-of-pocket (OOP) expenditures averted; (3) expected financial risk protection (FRP); and (4) productivity impact. Results: The MN package is expected to cost US$177 million and gain 155,000 HALYs (epilepsy US$37m and 64,500 HALYs; depression US$65m and 61,300 HALYs; bipolar disorder US$44m and 20,300 HALYs; and schizophrenia US$31m and 8,900 HALYs) annually. The health benefits would be concentrated among the poorest groups for all interventions. Universal public finance averts little household OOP expenditures and provides minimal FRP because of the low current utilization of these MN services in Ethiopia. In addition, economic benefits of US$ 51 million annually are expected from depression treatment in Ethiopia as a result of productivity gains, equivalent to 78% of the investment cost. Conclusions: The total MN package in Ethiopia is estimated to cost equivalent to US$1.8 per capita and yields large progressive health benefits. The expected productivity gain is substantially higher than the expected FRP. The ECEA approach seems to fit well with the current policy challenges and captures important equity concerns of scaling up MN programmes. PMID:27935798
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andretta, Vincenzo; Covino, Elvira; Giampapa, Mark S.
2017-04-20
Simultaneous, high-quality measurements of the neutral helium triplet features at 5876 Å and 10830 Å in a sample of solar-type stars are presented. The observations were made with ESO telescopes at the La Silla Paranal Observatory under program ID 088.D-0028(A) and MPG Utility Run for Fiber Extended-range Optical Spectrograph 088.A-9029(A). The equivalent widths of these features combined with chromospheric models are utilized to infer the fractional area coverage, or filling factor, of magnetic regions outside of spots. We find that the majority of the sample is characterized by filling factors less than unity. However, discrepancies occur among the coolest K-typemore » and the warmest and most rapidly rotating F-type dwarf stars. We discuss these apparently anomalous results and find that in the case of K-type stars, they are an artifact of the application of chromospheric models best suited to the Sun than to stars with significantly lower T {sub eff}. The case of the F-type rapid rotators can be explained by the measurement uncertainties of the equivalent widths, but they may also be due to a non-magnetic heating component in their atmospheres. With the exceptions noted above, preliminary results suggest that the average heating rates in the active regions are the same from one star to the other, differing in the spatially integrated, observed level of activity due to the area coverage. Hence, differences in activity in this sample are mainly due to the filling factor of active regions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, Imad, E-mail: iali@ouhsc.edu; Ahmad, Salahuddin
2013-10-01
To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatmentmore » sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.« less
Seeking consensus on universal health coverage indicators in the sustainable development goals.
Reddock, Jennifer
2017-01-01
There is optimism that the inclusion of universal health coverage in the Sustainable Development Goals advances its prominence in global and national health policy. However, formulating indicators for Target 3.8 through the Inter-Agency Expert Group on Sustainable Development Indicators has been challenging. Achieving consensus on the conceptual and methodological aspects of universal health coverage is likely to take some time in multi-stakeholder fora compared with national efforts to select indicators.
The influence of performance-based payment on childhood immunisation coverage.
Merilind, Eero; Salupere, Rauno; Västra, Katrin; Kalda, Ruth
2015-06-01
Pay-for-performance, also called the quality system (QS) in Estonia, was implemented in 2006 and one indicator for achievement is the childhood immunisation coverage rate. The WHO vaccination coverage in Europe for diphtheria, tetanus and pertussis, and measles in children aged around one year old should meet or exceed 90 per cent. The study was conducted using a database from the Estonian Health Insurance Fund. The study compared childhood immunisation coverage rates of all Estonian family physicians in two groups, joined and not joined to the quality system during the observation period 2006-2012. Immunisation coverage was calculated as the percentage of persons in the target age group who received a vaccine dose by a given age. The target level of immunisations in Estonia is set at 90 per cent and higher. Immunisation coverage rates of family doctors (FD) in Estonia showed significant differences between two groups of doctors: joined to the quality system and not joined. Doctors joined to the quality system met the 90 per cent vaccination criterion more frequently compared to doctors not joined to the quality system. Doctors not joined to the quality system were below the 90 per cent vaccination criterion in all vaccinations listed in the Estonian State Immunisation Schedule. Pay-for-performance as a financial incentive encourages higher levels of childhood immunisations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Yao; Chen, Josephine; Leary, Celeste I.
Radiation of the low neck can be accomplished using split-field intensity-modulated radiation therapy (sf-IMRT) or extended-field intensity-modulated radiation therapy (ef-IMRT). We evaluated the effect of these treatment choices on target coverage and thyroid and larynx doses. Using data from 14 patients with cancers of the oropharynx, we compared the following 3 strategies for radiating the low neck: (1) extended-field IMRT, (2) traditional split-field IMRT with an initial cord-junction block to 40 Gy, followed by a full-cord block to 50 Gy, and (3) split-field IMRT with a full-cord block to 50 Gy. Patients were planned using each of these 3 techniques.more » To facilitate comparison, extended-field plans were normalized to deliver 50 Gy to 95% of the neck volume. Target coverage was assessed using the dose to 95% of the neck volume (D{sub 95}). Mean thyroid and larynx doses were computed. Extended-field IMRT was used as the reference arm; the mean larynx dose was 25.7 ± 7.4 Gy, and the mean thyroid dose was 28.6 ± 2.4 Gy. Split-field IMRT with 2-step blocking reduced laryngeal dose (mean larynx dose 15.2 ± 5.1 Gy) at the cost of a moderate reduction in target coverage (D{sub 95} 41.4 ± 14 Gy) and much higher thyroid dose (mean thyroid dose 44.7 ± 3.7 Gy). Split-field IMRT with initial full-cord block resulted in greater laryngeal sparing (mean larynx dose 14.2 ± 5.1 Gy) and only a moderately higher thyroid dose (mean thyroid dose 31 ± 8 Gy) but resulted in a significant reduction in target coverage (D{sub 95} 34.4 ± 15 Gy). Extended-field IMRT comprehensively covers the low neck and achieves acceptable thyroid and laryngeal sparing. Split-field IMRT with a full-cord block reduces laryngeal doses to less than 20 Gy and spares the thyroid, at the cost of substantially reduced coverage of the low neck. Traditional 2-step split-field IMRT similarly reduces the laryngeal dose but also reduces low-neck coverage and delivers very high doses to the thyroid.« less
Nkiwane, Karen S; Pötter, Richard; Tanderup, Kari; Federico, Mario; Lindegaard, Jacob C; Kirisits, Christian
2013-01-01
Three-dimensional evaluation and comparison of target and organs at risk (OARs) doses from two traditional standard source loading patterns in the frame of MRI-guided cervical cancer brachytherapy for various clinical scenarios based on patient data collected in a multicenter trial setting. Two nonoptimized three-dimensional MRI-based treatment plans, Plan 1 (tandem and vaginal loading) and Plan 2 (tandem loading only), were generated for 134 patients from seven centers participating in the EMBRACE study. Both plans were normalized to point A (Pt. A). Target and OAR doses were evaluated in terms of minimum dose to 90% of the high-risk clinical target volume (HRCTV D90) grouped by tumor stage and minimum dose to the most exposed 2cm³ of the OARs volume. An HRCTV D90 ≥ Pt. A was achieved in 82% and 44% of the patients with Plans 1 and 2, respectively. Median HRCTV D90 with Plans 1 and 2 was 120% and 90% of Pt. A dose, respectively. Both plans had optimal dose coverage in 88% of Stage IB tumors; however, the tandem-only plan resulted in about 50% of dose reduction to the vagina and rectum. For Stages IIB and IIIB, Plan 1 had on average 35% better target coverage but with significant doses to OARs. Standard tandem loading alone results in good target coverage in most Stage IB tumors without violating OAR dose constraints. For Stage IIB tumors, standard vaginal loading improves the therapeutic window, however needs optimization to fulfill the dose prescription for target and OAR. In Stage IIIB, even optimized vaginal loading often does not fulfill the needs for dose prescription. The significant dose variation across various clinical scenarios for both target and OARs indicates the need for image-guided brachytherapy for optimal dose adaptation both for limited and advanced diseases. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Cross-National Differences in Special Education Coverage: An Empirical Analysis
ERIC Educational Resources Information Center
Anastasiou, Dimitris; Keller, Clayton E.
2014-01-01
This study investigated the role of educational and socioeconomic factors in explaining differences in national special education coverage. Data were derived from several international and governmental sources, targeting the year 2008 and covering 143 countries. Descriptive statistics revealed huge disparities in access to special education among…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Blake, E-mail: bsmith34@wisc.edu; Gelover,
Purpose: To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). Methods: Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam’s eye view over all energy layersmore » which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%–16.9%) and 5.18% (2.9%–7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%–22.6%) and 8.38% (4.7%–12.0%) for the DCS and fixed aperture plans, respectively. Conclusions: The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flampouri, S; Li, Z; Hoppe, B
2015-06-15
Purpose: To develop a treatment planning method for passively-scattered involved-node proton therapy of mediastinal lymphoma robust to breathing and cardiac motions. Methods: Beam-specific planning treatment volumes (bsPTV) are calculated for each proton field to incorporate pertinent uncertainties. Geometric margins are added laterally to each beam while margins for range uncertainty due to setup errors, breathing, and calibration curve uncertainties are added along each beam. The calculation of breathing motion and deformation effects on proton range includes all 4DCT phases. The anisotropic water equivalent margins are translated to distances on average 4DCT. Treatment plans are designed so each beam adequately coversmore » the corresponding bsPTV. For targets close to the heart, cardiac motion effects on dosemaps are estimated by using a library of anonymous ECG-gated cardiac CTs (cCT). The cCT, originally contrast-enhanced, are partially overridden to allow meaningful proton dose calculations. Targets similar to the treatment targets are drawn on one or more cCT sets matching the anatomy of the patient. Plans based on the average cCT are calculated on individual phases, then deformed to the average and accumulated. When clinically significant dose discrepancies occur between planned and accumulated doses, the patient plan is modified to reduce the cardiac motion effects. Results: We found that bsPTVs as planning targets create dose distributions similar to the conventional proton planning distributions, while they are a valuable tool for visualization of the uncertainties. For large targets with variability in motion and depth, integral dose was reduced because of the anisotropic margins. In most cases, heart motion has a clinically insignificant effect on target coverage. Conclusion: A treatment planning method was developed and used for proton therapy of mediastinal lymphoma. The technique incorporates bsPTVs compensating for all common sources of uncertainties and estimation of the effects of cardiac motion not commonly performed.« less
42 CFR 435.229 - Optional targeted low-income children.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Optional targeted low-income children. 435.229... Coverage of Families and Children § 435.229 Optional targeted low-income children. The agency may provide Medicaid to— (a) All individuals under age 19 who are optional targeted low-income children as defined in...
42 CFR 435.229 - Optional targeted low-income children.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Optional targeted low-income children. 435.229... Coverage of Families and Children § 435.229 Optional targeted low-income children. The agency may provide Medicaid to— (a) All individuals under age 19 who are optional targeted low-income children as defined in...
42 CFR 435.229 - Optional targeted low-income children.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Optional targeted low-income children. 435.229... Coverage of Families and Children § 435.229 Optional targeted low-income children. The agency may provide Medicaid to— (a) All individuals under age 19 who are optional targeted low-income children as defined in...
Coverage-guaranteed sensor node deployment strategies for wireless sensor networks.
Fan, Gaojuan; Wang, Ruchuan; Huang, Haiping; Sun, Lijuan; Sha, Chao
2010-01-01
Deployment quality and cost are two conflicting aspects in wireless sensor networks. Random deployment, where the monitored field is covered by randomly and uniformly deployed sensor nodes, is an appropriate approach for large-scale network applications. However, their successful applications depend considerably on the deployment quality that uses the minimum number of sensors to achieve a desired coverage. Currently, the number of sensors required to meet the desired coverage is based on asymptotic analysis, which cannot meet deployment quality due to coverage overestimation in real applications. In this paper, we first investigate the coverage overestimation and address the challenge of designing coverage-guaranteed deployment strategies. To overcome this problem, we propose two deployment strategies, namely, the Expected-area Coverage Deployment (ECD) and BOundary Assistant Deployment (BOAD). The deployment quality of the two strategies is analyzed mathematically. Under the analysis, a lower bound on the number of deployed sensor nodes is given to satisfy the desired deployment quality. We justify the correctness of our analysis through rigorous proof, and validate the effectiveness of the two strategies through extensive simulation experiments. The simulation results show that both strategies alleviate the coverage overestimation significantly. In addition, we also evaluate two proposed strategies in the context of target detection application. The comparison results demonstrate that if the target appears at the boundary of monitored region in a given random deployment, the average intrusion distance of BOAD is considerably shorter than that of ECD with the same desired deployment quality. In contrast, ECD has better performance in terms of the average intrusion distance when the invasion of intruder is from the inside of monitored region.
Multi-Agent Cooperative Target Search
Hu, Jinwen; Xie, Lihua; Xu, Jun; Xu, Zhao
2014-01-01
This paper addresses a vision-based cooperative search for multiple mobile ground targets by a group of unmanned aerial vehicles (UAVs) with limited sensing and communication capabilities. The airborne camera on each UAV has a limited field of view and its target discriminability varies as a function of altitude. First, by dividing the whole surveillance region into cells, a probability map can be formed for each UAV indicating the probability of target existence within each cell. Then, we propose a distributed probability map updating model which includes the fusion of measurement information, information sharing among neighboring agents, information decay and transmission due to environmental changes such as the target movement. Furthermore, we formulate the target search problem as a multi-agent cooperative coverage control problem by optimizing the collective coverage area and the detection performance. The proposed map updating model and the cooperative control scheme are distributed, i.e., assuming that each agent only communicates with its neighbors within its communication range. Finally, the effectiveness of the proposed algorithms is illustrated by simulation. PMID:24865884
Minetti, Andrea; Hurtado, Northan; Grais, Rebecca F.; Ferrari, Matthew
2014-01-01
Current mass vaccination campaigns in measles outbreak response are nonselective with respect to the immune status of individuals. However, the heterogeneity in immunity, due to previous vaccination coverage or infection, may lead to potential bias of such campaigns toward those with previous high access to vaccination and may result in a lower-than-expected effective impact. During the 2010 measles outbreak in Malawi, only 3 of the 8 districts where vaccination occurred achieved a measureable effective campaign impact (i.e., a reduction in measles cases in the targeted age groups greater than that observed in nonvaccinated districts). Simulation models suggest that selective campaigns targeting hard-to-reach individuals are of greater benefit, particularly in highly vaccinated populations, even for low target coverage and with late implementation. However, the choice between targeted and nonselective campaigns should be context specific, achieving a reasonable balance of feasibility, cost, and expected impact. In addition, it is critical to develop operational strategies to identify and target hard-to-reach individuals. PMID:24131555
SU-F-T-419: Evaluation of PlanIQ Feasibility DVH as Planning Objectives for Skull Base SBRT Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, W; Wang, H; Chi, P
2016-06-15
Purpose: PlanIQ(Sun Nuclear Corporation) can provide feasibility measures on organs-at-risk(OARs) around the target based on depth, local anatomy density and energy of radiation beam used. This study is to test and evaluate PlanIQ feasibility DVHs as optimization objectives in the treatment planning process, and to investigate the potential to use them in routine clinical cases to improve planning efficiency. Methods: Two to three arcs VMAT Treatment plans were generated in Pinnacle based on PlanIQ feasibility DVH for six skull base patients who previously treated with SBRT. The PlanIQ feasibility DVH for each OAR consists of four zones – impossible (atmore » 100% target coverage), difficult, challenging and probable. Constrains to achieve DVH in difficult zone were used to start plan optimization. Further adjustment was made to improve coverage. The plan DVHs were compared to PlanIQ feasibility DVH to assess the dose received by 0%(D0), 5%(D5), 10%(D10) and 50%(D50) of the OAR volumes. Results: A total of 90 OARs were evaluated for 6 patients (mean 15 OARs, range 11–18 OARs). We used >98% PTV coverage as planning goal since it’s difficult to achieve 100% target coverage. For the generated plans, 96.7% of the OARs achieved D0 or D5 within difficult zone or impossible zone (ipsilateral OARs 93.5%, contralateral OARs 100%), while 90% and 65.6% of the OARs achieved D10 and D50 within difficult zone, respectively. Seventeen of the contralateral and out of field OARs achieved DVHs in impossible zone. For OARs adjacent or overlapped with target volume, the D0 and D5 are challenging to be optimized into difficult zone. All plans were completed within 2–4 adjustments to improve target coverage and uniformity. Conclusion: PlanIQ feasibility tool has the potential to provide difficult but achievable initial optimization objectives and therefore reduce the planning time to obtain a well optimized plan.« less
TU-AB-BRB-02: Stochastic Programming Methods for Handling Uncertainty and Motion in IMRT Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unkelbach, J.
The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-15
...This final rule implements provisions of the Patient Protection and Affordable Care Act and the Health Care and Education Reconciliation Act of 2010 (collectively referred to as the Affordable Care Act. This final rule finalizes new Medicaid eligibility provisions; finalizes changes related to electronic Medicaid and the Children's Health Insurance Program (CHIP) eligibility notices and delegation of appeals; modernizes and streamlines existing Medicaid eligibility rules; revises CHIP rules relating to the substitution of coverage to improve the coordination of CHIP coverage with other coverage; and amends requirements for benchmark and benchmark- equivalent benefit packages consistent with sections 1937 of the Social Security Act (which we refer to as ``alternative benefit plans'') to ensure that these benefit packages include essential health benefits and meet certain other minimum standards. This rule also implements specific provisions including those related to authorized representatives, notices, and verification of eligibility for qualifying coverage in an eligible employer-sponsored plan for Affordable Insurance Exchanges. This rule also updates and simplifies the complex Medicaid premium and cost sharing requirements, to promote the most effective use of services, and to assist states in identifying cost sharing flexibilities. It includes transition policies for 2014 as applicable.
Research on the effect of coverage rate on the surface quality in laser direct writing process
NASA Astrophysics Data System (ADS)
Pan, Xuetao; Tu, Dawei
2017-07-01
Direct writing technique is usually used in femtosecond laser two-photon micromachining. The size of the scanning step is an important factor affecting the surface quality and machining efficiency of micro devices. According to the mechanism of two-photon polymerization, combining the distribution function of light intensity and the free radical concentration theory, we establish the mathematical model of coverage of solidification unit, then analyze the effect of coverage on the machining quality and efficiency. Using the principle of exposure equivalence, we also obtained the analytic expressions of the relationship among the surface quality characteristic parameters of microdevices and the scanning step, and carried out the numerical simulation and experiment. The results show that the scanning step has little influence on the surface quality of the line when it is much smaller than the size of the solidification unit. However, with increasing scanning step, the smoothness of line surface is reduced rapidly, and the surface quality becomes much worse.
Soh, Jun Hui; Lin, Yiyang; Rana, Subinoy; Ying, Jackie Y; Stevens, Molly M
2015-08-04
A versatile and sensitive colorimetric assay that allows the rapid detection of small-molecule targets using the naked eye is demonstrated. The working principle of the assay integrates aptamer-target recognition and the aptamer-controlled growth of gold nanoparticles (Au NPs). Aptamer-target interactions modulate the amount of aptamer strands adsorbed on the surface of aptamer-functionalized Au NPs via desorption of the aptamer strands when target molecules bind with the aptamer. Depending on the resulting aptamer coverage, Au NPs grow into morphologically varied nanostructures, which give rise to different colored solutions. Au NPs with low aptamer coverage grow into spherical NPs, which produce red-colored solutions, whereas Au NPs with high aptamer coverage grow into branched NPs, which produce blue-colored solutions. We achieved visible colorimetric response and nanomolar detection limits for the detection of ochratoxin A (1 nM) in red wine samples, as well as cocaine (1 nM) and 17β-estradiol (0.2 nM) in spiked synthetic urine and saliva, respectively. The detection limits were well within clinically and physiologically relevant ranges, and below the maximum food safety limits. The assay is highly sensitive, specific, and able to detect an array of analytes rapidly without requiring sophisticated equipment, making it relevant for many applications, such as high-throughput drug and clinical screening, food sampling, and diagnostics. Furthermore, the assay is easily adapted as a chip-based platform for rapid and portable target detection.
Role of step size and max dwell time in anatomy based inverse optimization for prostate implants
Manikandan, Arjunan; Sarkar, Biplab; Rajendran, Vivek Thirupathur; King, Paul R.; Sresty, N.V. Madhusudhana; Holla, Ragavendra; Kotur, Sachin; Nadendla, Sujatha
2013-01-01
In high dose rate (HDR) brachytherapy, the source dwell times and dwell positions are vital parameters in achieving a desirable implant dose distribution. Inverse treatment planning requires an optimal choice of these parameters to achieve the desired target coverage with the lowest achievable dose to the organs at risk (OAR). This study was designed to evaluate the optimum source step size and maximum source dwell time for prostate brachytherapy implants using an Ir-192 source. In total, one hundred inverse treatment plans were generated for the four patients included in this study. Twenty-five treatment plans were created for each patient by varying the step size and maximum source dwell time during anatomy-based, inverse-planned optimization. Other relevant treatment planning parameters were kept constant, including the dose constraints and source dwell positions. Each plan was evaluated for target coverage, urethral and rectal dose sparing, treatment time, relative target dose homogeneity, and nonuniformity ratio. The plans with 0.5 cm step size were seen to have clinically acceptable tumor coverage, minimal normal structure doses, and minimum treatment time as compared with the other step sizes. The target coverage for this step size is 87% of the prescription dose, while the urethral and maximum rectal doses were 107.3 and 68.7%, respectively. No appreciable difference in plan quality was observed with variation in maximum source dwell time. The step size plays a significant role in plan optimization for prostate implants. Our study supports use of a 0.5 cm step size for prostate implants. PMID:24049323
Gauer, Tobias; Sothmann, Thilo; Blanck, Oliver; Petersen, Cordula; Werner, René
2018-06-01
Radiotherapy of extracranial metastases changed from normofractioned 3D CRT to extreme hypofractionated stereotactic treatment using VMAT beam techniques. Random interaction between tumour motion and dynamically changing beam parameters might result in underdosage of the CTV even for an appropriately dimensioned ITV (interplay effect). This study presents a clinical scenario of extreme hypofractionated stereotactic treatment and analyses the impact of interplay effects on CTV dose coverage. For a thoracic/abdominal phantom with an integrated high-resolution detector array placed on a 4D motion platform, dual-arc treatment plans with homogenous target coverage were created using a common VMAT technique and delivered in a single fraction. CTV underdosage through interplay effects was investigated by comparing dose measurements with and without tumour motion during plan delivery. Our study agrees with previous works that pointed out insignificant interplay effects on target coverage for very regular tumour motion patterns like simple sinusoidal motion. However, we identified and illustrated scenarios that are likely to result in a clinically relevant CTV underdosage. For tumour motion with abnormal variability, target coverage quantified by the CTV area receiving more than 98% of the prescribed dose decreased to 78% compared to 100% at static dose measurement. This study is further proof of considerable influence of interplay effects on VMAT dose delivery in stereotactic radiotherapy. For selected conditions of an exemplary scenario, interplay effects and related motion-induced target underdosage primarily occurred in tumour motion pattern with increased motion variability and VMAT plan delivery using complex MLC dose modulation.
Abdullah, Asnawi; Hort, Krishna; Abidin, Azwar Zaenal; Amin, Fadilah M
2012-01-01
Despite significant investment in improving service infrastructure and training of staff, public primary healthcare services in low-income and middle-income countries tend to perform poorly in reaching coverage targets. One of the factors identified in Aceh, Indonesia was the lack of operational funds for service provision. The objective of this study was to develop a simple and transparent costing tool that enables health planners to calculate the unit costs of providing basic health services to estimate additional budgets required to deliver services in accordance with national targets. The tool was developed using a standard economic approach that linked the input activities to achieving six national priority programs at primary healthcare level: health promotion, sanitation and environment health, maternal and child health and family planning, nutrition, immunization and communicable diseases control, and treatment of common illness. Costing was focused on costs of delivery of the programs that need to be funded by local government budgets. The costing tool consisting of 16 linked Microsoft Excel worksheets was developed and tested in several districts enabled the calculation of the unit costs of delivering of the six national priority programs per coverage target of each program (such as unit costs of delivering of maternal and child health program per pregnant mother). This costing tool can be used by health planners to estimate additional money required to achieve a certain level of coverage of programs, and it can be adjusted for different costs and program delivery parameters in different settings. Copyright © 2012 John Wiley & Sons, Ltd.
Evaluation of the measles, mumps and rubella vaccination catch-up campaign in England in 2013.
Simone, Benedetto; Balasegaram, Sooria; Gobin, Maya; Anderson, Charlotte; Charlett, André; Coole, Louise; Maguire, Helen; Nichols, Tom; Rawlings, Chas; Ramsay, Mary; Oliver, Isabel
2014-08-06
In January-March 2013 in England, confirmed measles cases increased in children aged 10-16 years. In April-September 2013, the National Health System and Public Health England launched a national measles-mumps-rubella (MMR) campaign based on data from Child Health Information Systems (CHIS) estimating that approximately 8% in this age group were unvaccinated. We estimated coverage at baseline, and, of those unvaccinated (target), the proportion vaccinated up to 20/08/2013 (mid-point) to inform further public health action. We selected a sample of 6644 children aged 10-16 years using multistage sampling from those reported unvaccinated in CHIS at baseline and validated their records against GP records. We adjusted the CHIS MMR vaccine coverage estimates correcting by the proportion of vaccinated children obtained through sample validation. We validated 5179/6644 (78%) of the sample records. Coverage at baseline was estimated as 94.7% (95% confidence intervals, CI: 93.5-96.0%), lower in London (86.9%, 95%CI: 83.0-90.9%) than outside (96.1%, 95%CI 95.5-96.8%). The campaign reached 10.8% (95%CI: 7.0-14.6%) of the target population, lower in London (7.1%, 95%CI: 4.9-9.3) than in the rest of England (11.4%, 95%CI: 7.0-15.9%). Coverage increased by 0.5% up to 95.3% (95% CI: 94.1-96.4%) but an estimated 210,000 10-16 year old children remained unvaccinated nationally. Baseline MMR coverage was higher than previously reported and was estimated to have reached the 95% campaign objective at midpoint. Eleven per cent of the target population were vaccinated during the campaign, and may be underestimated, especially in London. No further national campaigns are needed but targeted local vaccination activities should be considered. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syh, J; Syh, J; Patel, B
Purpose: This case study was designated to confirm the optimized plan was used to treat skin surface of left leg in three stages. 1. To evaluate dose distribution and plan quality by alternating of the source loading catheters pattern in flexible Freiberg Flap skin surface (FFSS) applicator. 2. To investigate any impact on Dose Volume Histogram (DVH) of large superficial surface target volume coverage. 3. To compare the dose distribution if it was treated with electron beam. Methods: The Freiburg Flap is a flexible mesh style surface mold for skin radiation or intraoperative surface treatments. The Freiburg Flap consists ofmore » multiple spheres that are attached to each other, holding and guiding up to 18 treatment catheters. The Freiburg Flap also ensures a constant distance of 5mm from the treatment catheter to the surface. Three treatment trials with individual planning optimization were employed: 18 channels, 9 channels of FF and 6 MeV electron beam. The comparisons were highlighted in target coverage, dose conformity and dose sparing of surrounding tissues. Results: The first 18 channels brachytherapy plan was generated with 18 catheters inside the skin-wrapped up flap (Figure 1A). A second 9 catheters plan was generated associated with the same calculation points which were assigned to match prescription for target coverage as 18 catheters plan (Figure 1B). The optimized inverse plan was employed to reduce the dose to adjacent structures such as tibia or fibula. The comparison of DVH’s was depicted on Figure 2. External beam of electron RT plan was depicted in Figure 3. Overcall comparisons among these three were illustrated in Conclusion: The 9-channel Freiburg flap flexible skin applicator offers a reasonably acceptable plan without compromising the coverage. Electron beam was discouraged to use to treat curved skin surface because of low target coverage and high dose in adjacent tissues.« less
Gao, Shuqin; Pan, Xu; Cui, Qingguo; Hu, Yukun; Ye, Xuehua; Dong, Ming
2014-01-01
Plant interactions greatly affect plant community structure. Dryland ecosystems are characterized by low amounts of unpredictable precipitation as well as by often having biological soil crusts (BSCs) on the soil surface. In dryland plant communities, plants interact mostly as they compete for water resources, and the direction and intensity of plant interaction varies as a function of the temporal fluctuation in water availability. Since BSCs influence water redistribution to some extent, a greenhouse experiment was conducted to test the hypothesis that the intensity and direction of plant interactions in a dryland plant community can be modified by BSCs. In the experiment, 14 combinations of four plant species (Artemisia ordosica, Artemisia sphaerocephala, Chloris virgata and Setaria viridis) were subjected to three levels of coverage of BSCs and three levels of water supply. The results show that: 1) BSCs affected plant interaction intensity for the four plant species: a 100% coverage of BSCs significantly reduced the intensity of competition between neighboring plants, while it was highest with a 50% coverage of BSCs in combination with the target species of A. sphaerocephala and C. virgata; 2) effects of the coverage of BSCs on plant interactions were modified by water regime when the target species were C. virgata and S. viridis; 3) plant interactions were species-specific. In conclusion, the percent coverage of BSCs affected plant interactions, and the effects were species-specific and could be modified by water regimes. Further studies should focus on effects of the coverage of BSCs on plant-soil hydrological processes. PMID:24498173
Gao, Shuqin; Pan, Xu; Cui, Qingguo; Hu, Yukun; Ye, Xuehua; Dong, Ming
2014-01-01
Plant interactions greatly affect plant community structure. Dryland ecosystems are characterized by low amounts of unpredictable precipitation as well as by often having biological soil crusts (BSCs) on the soil surface. In dryland plant communities, plants interact mostly as they compete for water resources, and the direction and intensity of plant interaction varies as a function of the temporal fluctuation in water availability. Since BSCs influence water redistribution to some extent, a greenhouse experiment was conducted to test the hypothesis that the intensity and direction of plant interactions in a dryland plant community can be modified by BSCs. In the experiment, 14 combinations of four plant species (Artemisia ordosica, Artemisia sphaerocephala, Chloris virgata and Setaria viridis) were subjected to three levels of coverage of BSCs and three levels of water supply. The results show that: 1) BSCs affected plant interaction intensity for the four plant species: a 100% coverage of BSCs significantly reduced the intensity of competition between neighboring plants, while it was highest with a 50% coverage of BSCs in combination with the target species of A. sphaerocephala and C. virgata; 2) effects of the coverage of BSCs on plant interactions were modified by water regime when the target species were C. virgata and S. viridis; 3) plant interactions were species-specific. In conclusion, the percent coverage of BSCs affected plant interactions, and the effects were species-specific and could be modified by water regimes. Further studies should focus on effects of the coverage of BSCs on plant-soil hydrological processes.
Maina, Isabella; Wanjala, Pepela; Soti, David; Kipruto, Hillary; Droti, Benson; Boerma, Ties
2017-10-01
To develop a systematic approach to obtain the best possible national and subnational statistics for maternal and child health coverage indicators from routine health-facility data. Our approach aimed to obtain improved numerators and denominators for calculating coverage at the subnational level from health-facility data. This involved assessing data quality and determining adjustment factors for incomplete reporting by facilities, then estimating local target populations based on interventions with near-universal coverage (first antenatal visit and first dose of pentavalent vaccine). We applied the method to Kenya at the county level, where routine electronic reporting by facilities is in place via the district health information software system. Reporting completeness for facility data were well above 80% in all 47 counties and the consistency of data over time was good. Coverage of the first dose of pentavalent vaccine, adjusted for facility reporting completeness, was used to obtain estimates of the county target populations for maternal and child health indicators. The country and national statistics for the four-year period 2012/13 to 2015/16 showed good consistency with results of the 2014 Kenya demographic and health survey. Our results indicated a stagnation of immunization coverage in almost all counties, a rapid increase of facility-based deliveries and caesarean sections and limited progress in antenatal care coverage. While surveys will continue to be necessary to provide population-based data, web-based information systems for health facility reporting provide an opportunity for more frequent, local monitoring of progress, in maternal and child health.
A Target Coverage Scheduling Scheme Based on Genetic Algorithms in Directional Sensor Networks
Gil, Joon-Min; Han, Youn-Hee
2011-01-01
As a promising tool for monitoring the physical world, directional sensor networks (DSNs) consisting of a large number of directional sensors are attracting increasing attention. As directional sensors in DSNs have limited battery power and restricted angles of sensing range, maximizing the network lifetime while monitoring all the targets in a given area remains a challenge. A major technique to conserve the energy of directional sensors is to use a node wake-up scheduling protocol by which some sensors remain active to provide sensing services, while the others are inactive to conserve their energy. In this paper, we first address a Maximum Set Covers for DSNs (MSCD) problem, which is known to be NP-complete, and present a greedy algorithm-based target coverage scheduling scheme that can solve this problem by heuristics. This scheme is used as a baseline for comparison. We then propose a target coverage scheduling scheme based on a genetic algorithm that can find the optimal cover sets to extend the network lifetime while monitoring all targets by the evolutionary global search technique. To verify and evaluate these schemes, we conducted simulations and showed that the schemes can contribute to extending the network lifetime. Simulation results indicated that the genetic algorithm-based scheduling scheme had better performance than the greedy algorithm-based scheme in terms of maximizing network lifetime. PMID:22319387
Rublee, Dale A; Burke, James P
2010-03-01
As clinical trials have shown the benefits of more intensive cholesterol control, treatment targets for low-density lipoprotein cholesterol (LDL-C) have decreased progressively. At the same time, physicians have been encouraged to contain costs by prescribing cheaper, generic statins for cholesterol management. To determine how these possibly conflicting goals are managed in clinical practice, we examined LDL-C control in patients switched from a potent, branded statin (atorvastatin) to a less potent, generic statin (simvastatin). Patients who switched from atorvastatin to simvastatin between July 2006 and January 2008 were retrospectively identified from a US medical and pharmacy claims database, and matched with controls remaining on atorvastatin. Outcomes measured were the number of switched patients receiving a simvastatin milligram dose>or=2 times their previous atorvastatin dose, changes in LDL-C levels, and percentage of patients achieving recommended LDL-C targets. All study variables were analyzed descriptively. After applying exclusion and inclusion criteria, 1048 patients who switched from atorvastatin to simvastatin and 1048 matched controls who remained on atorvastatin were included. Among the switchers, 379 (36%) received an inappropriately low dose of simvastatin (<2 times atorvastatin dose). In patients remaining on atorvastatin, mean LDL-C decreased from 105.7 mg/dL to 102.3 mg/dL after 44 weeks, whereas in switched patients, LDL-C remained similar, at 105.9 mg/dL on atorvastatin and 105.8 mg/dL on simvastatin. Before switching, when all patients were receiving atorvastatin, 67.4% of switchers and 69.9% of controls achieved recommended LDL-C targets. After switching, significantly fewer switchers than controls met LDL-C targets (69.1% vs 74.6%; P=0.005). However, among patients who switched to an equivalent dose of simvastatin (>or=2 times prior atorvastatin dose), similar proportions met LDL-C targets (72.8% vs 74.6% of controls; P=0.402), whereas among patients who switched to inappropriate non-equivalent dose of simvastatin, a significantly lower proportion met LDL-C targets (62.5% vs 74.6% of controls; P=0.001). Continuing atorvastatin was associated with lower LDL-C levels and better LDL-C target attainment compared with switching to simvastatin. Patients switched to an equivalent simvastatin dose had lower LDL-C levels and were more likely to achieve LDL-C targets than patients switched to a non-equivalent dose, suggesting physicians must consider dosage equivalence when switching statins, and should measure LDL-C and titrate statins as necessary to achieve LDL-C control.
CCTV Coverage Index Based on Surveillance Resolution and Its Evaluation Using 3D Spatial Analysis
Choi, Kyoungah; Lee, Impyeong
2015-01-01
We propose a novel approach to evaluating how effectively a closed circuit television (CCTV) system can monitor a targeted area. With 3D models of the target area and the camera parameters of the CCTV system, the approach produces surveillance coverage index, which is newly defined in this study as a quantitative measure for surveillance performance. This index indicates the proportion of the space being monitored with a sufficient resolution to the entire space of the target area. It is determined by computing surveillance resolution at every position and orientation, which indicates how closely a specific object can be monitored with a CCTV system. We present full mathematical derivation for the resolution, which depends on the location and orientation of the object as well as the geometric model of a camera. With the proposed approach, we quantitatively evaluated the surveillance coverage of a CCTV system in an underground parking area. Our evaluation process provided various quantitative-analysis results, compelling us to examine the design of the CCTV system prior to its installation and understand the surveillance capability of an existing CCTV system. PMID:26389909
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forde, Elizabeth, E-mail: eforde@tcd.ie; Kneebone, Andrew; Northern Clinical School, University of Sydney, New South Wales
2013-10-01
The purpose of this study was to compare postprostatectomy planning for volumetric-modulated arc therapy (VMAT) with both single arc (SA) and double arcs (DA) against dynamic sliding window intensity-modulated radiotherapy (IMRT). Ten cases were planned with IMRT, SA VMAT, and DA VMAT. All cases were planned to achieve a minimum dose of 68 Gy to 95% of the planning target volume (PTV) and goals to limit rectal volume >40 Gy to 35% and >65 Gy to 17%, and bladder volumes >40 Gy to 50% and >65 Gy to 25%. Plans were averaged across the 10 patients and compared for meanmore » dose, conformity, homogeneity, rectal and bladder doses, and monitor units. The mean dose to the clinical target volume and PTV was significantly higher (p<0.05) for SA compared with DA or IMRT. The homogeneity index was not significantly different: SA = 0.09; DA = 0.08; and IMRT = 0.07. The rectal V40 was lowest for the DA plan. The rectal V20 was significantly lower (p<0.05) for both the VMAT plans compared with IMRT. There were no significant differences for bladder V40 or rectal and bladder V65. The IMRT plans required 1400 MU compared with 745 for DA and 708 for SA. This study shows that for equivalent dose coverage, SA and DA VMAT plans result in higher mean doses to the clinical target volume and PTV. This greater dose heterogeneity is balanced by improved low-range rectal doses and halving of the monitor units.« less
Yonai, Shunsuke; Matsufuji, Naruhiro; Akahane, Keiichi
2018-04-23
The aim of this work was to estimate typical dose equivalents to out-of-field organs during carbon-ion radiotherapy (CIRT) with a passive beam for prostate cancer treatment. Additionally, sensitivity analyses of organ doses for various beam parameters and phantom sizes were performed. Because the CIRT out-of-field dose depends on the beam parameters, the typical values of those parameters were determined from statistical data on the target properties of patients who received CIRT at the Heavy-Ion Medical Accelerator in Chiba (HIMAC). Using these typical beam-parameter values, out-of-field organ dose equivalents during CIRT for typical prostate treatment were estimated by Monte Carlo simulations using the Particle and Heavy-Ion Transport Code System (PHITS) and the ICRP reference phantom. The results showed that the dose decreased with distance from the target, ranging from 116 mSv in the testes to 7 mSv in the brain. The organ dose equivalents per treatment dose were lower than those either in 6-MV intensity-modulated radiotherapy or in brachytherapy with an Ir-192 source for organs within 40 cm of the target. Sensitivity analyses established that the differences from typical values were within ∼30% for all organs, except the sigmoid colon. The typical out-of-field organ dose equivalents during passive-beam CIRT were shown. The low sensitivity of the dose equivalent in organs farther than 20 cm from the target indicated that individual dose assessments required for retrospective epidemiological studies may be limited to organs around the target in cases of passive-beam CIRT for prostate cancer. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
2007-02-01
bladder and the rectum are overprotected while the PTV coverage is undesirably reduced. On the other hand, if their maximum dose is increased and/or...B, the bladder and rectum were overprotected with undesirably low PTV coverage (84.54%). The reduction of their weighting factor increased PTV
Ferrinho, Paulo; Dramé, Mohamed; Biai, Sidu; Lopes, Orlando; Sousa, Fernando de; Van Lerberghe, Wim
2013-01-01
Although many countries have improved vaccination coverage in recent years, some, including Guinea-Bissau, failed to meet expected targets. This paper tries to understand the main barriers to better vaccination coverage in the context of the GAVI-Alliance (The Global Alliance for Vaccines and Immunisation) cash-based support provided to Guinea-Bissau. The analysis is based on a document analysis and a three round Delphi study with a final consensus meeting. Consensus attributed about 25% of the failure to perform better to implementation problems; and about 10% to governance and also 10% to scarce resources. The qualitative analysis validates the importance of implementation issues and upgraded the relevance of the human resources crisis as an important drawback. The recommendations were balanced in their upstream-downstream focus but were blind to health information issues and logistical difficulties. It is commendable that such a fragile state, with all sorts of barriers, manages to sustain a slow steady growth of its vaccination coverage. Not reaching the targets set reflects the inappropriateness of those targets rather than a lack of commitment of the health workforce. In the unstable context of countries such as Guinea-Bissau, the predictability of the funds from global health initiatives like the GAVI-Alliance seem to make all the difference in achieving small consistent health gains even in the presence of other major bottlenecks.
Amirthalingam, Gayatri; Andrews, Nick; Keel, Philip; Mullett, David; Correa, Ana; de Lusignan, Simon; Ramsay, Mary
2018-02-01
In 2013, a herpes zoster vaccination programme was introduced in England for adults aged 70 years with a phased catch-up programme for those aged 71-79 years. We aimed to evaluate the effect of the first 3 years of the vaccination programme on incidence of herpes zoster and postherpetic neuralgia in this population. In this population-based study, we extracted data from the Royal College of General Practitioners sentinel primary care network on consultations with patients aged 60-89 years for herpes zoster and postherpetic neuralgia occurring between Oct 1, 2005, and Sept 30, 2016, obtaining data from 164 practices. We identified individual data on herpes zoster vaccinations administered and consultations for herpes zoster and postherpetic neuralgia, and aggregated these data to estimate vaccine coverage and incidence of herpes zoster and postherpetic neuralgia consultations. We defined age cohorts to identify participants targeted in each year of the programme, and as part of the routine or catch-up programme. We modelled incidence according to age, region, gender, time period, and vaccine eligibility using multivariable Poisson regression with an offset for person-years. Our analysis included 3·36 million person-years of data, corresponding to an average of 310 001 patients aged 60-89 years who were registered at an RCGP practice each year. By Aug 31, 2016, uptake of the vaccine varied between 58% for the recently targeted cohorts and 72% for the first routine cohort. Across the first 3 years of vaccination for the three routine cohorts, incidence of herpes zoster fell by 35% (incidence rate ratio 0·65 [95% 0·60-0·72]) and of postherpetic neuralgia fell by 50% (0·50 [0·38-0·67]). The equivalent reduction for the four catch-up cohorts was 33% for herpes zoster (incidence rate ratio 0·67 [0·61-0·74]) and 38% for postherpetic neuralgia (0·62 [0·50-0·79]). These reductions are consistent with a vaccine effectiveness of about 62% against herpes zoster and 70-88% against postherpetic neuralgia. The herpes zoster vaccination programme in England has had a population impact equivalent to about 17 000 fewer episodes of herpes zoster and 3300 fewer episodes of postherpetic neuralgia among 5·5 million eligible individuals in the first 3 years of the programme. Communication of the public health impact of this programme will be important to reverse the recent trend of declining vaccine coverage. Public Health England. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY-NC-ND 4.0 license. Published by Elsevier Ltd.. All rights reserved.
Kundrick, Avery; Huang, Zhuojie; Carran, Spencer; Kagoli, Matthew; Grais, Rebecca Freeman; Hurtado, Northan; Ferrari, Matthew
2018-06-15
Despite progress towards increasing global vaccination coverage, measles continues to be one of the leading, preventable causes of death among children worldwide. Whether and how to target sub-national areas for vaccination campaigns continues to remain a question. We analyzed three metrics for prioritizing target areas: vaccination coverage, susceptible birth cohort, and the effective reproductive ratio (R E ) in the context of the 2010 measles epidemic in Malawi. Using case-based surveillance data from the 2010 measles outbreak in Malawi, we estimated vaccination coverage from the proportion of cases reporting with a history of prior vaccination at the district and health facility catchment scale. Health facility catchments were defined as the set of locations closer to a given health facility than to any other. We combined these estimates with regional birth rates to estimate the size of the annual susceptible birth cohort. We also estimated the effective reproductive ratio, R E , at the health facility polygon scale based on the observed rate of exponential increase of the epidemic. We combined these estimates to identify spatial regions that would be of high priority for supplemental vaccination activities. The estimated vaccination coverage across all districts was 84%, but ranged from 61 to 99%. We found that 8 districts and 354 health facility catchments had estimated vaccination coverage below 80%. Areas that had highest birth cohort size were frequently large urban centers that had high vaccination coverage. The estimated R E ranged between 1 and 2.56. The ranking of districts and health facility catchments as priority areas varied depending on the measure used. Each metric for prioritization may result in discrete target areas for vaccination campaigns; thus, there are tradeoffs to choosing one metric over another. However, in some cases, certain areas may be prioritized by all three metrics. These areas should be treated with particular concern. Furthermore, the spatial scale at which each metric is calculated impacts the resulting prioritization and should also be considered when prioritizing areas for vaccination campaigns. These methods may be used to allocate effort for prophylactic campaigns or to prioritize response for outbreak response vaccination.
42 CFR 435.4 - Definitions and use of terms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... disabled individual; Optional targeted low-income child means a child under age 19 who meets the financial and categorical standards described below. (1) Financial need. An optional targeted low-income child... optional targeted low-income child is not covered under a group health plan or health insurance coverage...
Kanya, Lucy; Obare, Francis; Warren, Charlotte; Abuya, Timothy; Askew, Ian; Bellows, Ben
2014-07-01
There has been increased interest in and experimentation with demand-side mechanisms such as the use of vouchers that place purchasing power in the hands of targeted consumers to improve the uptake of healthcare services in low-income settings. A key measure of the success of such interventions is the extent to which the programmes have succeeded in reaching the target populations. This article estimates the coverage of facility deliveries by a maternal health voucher programme in South-western Uganda and examines whether such coverage is correlated with district-level characteristics such as poverty density and the number of contracted facilities. Analysis entails estimating the voucher coverage of health facility deliveries among the general population and poor population (PP) using programme data for 2010, which was the most complete calendar year of implementation of the Uganda safe motherhood (SM) voucher programme. The results show that: (1) the programme paid for 38% of estimated deliveries among the PP in the targeted districts, (2) there was a significant negative correlation between the poverty density in a district and proportions of births to poor women that were covered by the programme and (3) improving coverage of health facility deliveries for poor women is dependent upon increasing the sales and redemption rates. The findings suggest that to the extent that the programme stimulated demand for SM services by new users, it has the potential of increasing facility-based births among poor women in the region. In addition, the significant negative correlation between the poverty density and the proportions of facility-based births to poor women that are covered by the voucher programme suggests that there is need to increase both voucher sales and the rate of redemption to improve coverage in districts with high levels of poverty. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2013; all rights reserved.
Arbyn, Marc; Fabri, Valérie; Temmerman, Marleen; Simoens, Cindy
2014-01-01
To assess the coverage for cervical cancer screening as well as the use of cervical cytology, colposcopy and other diagnostic and therapeutic interventions on the uterine cervix in Belgium, using individual health insurance data. The Intermutualistic Agency compiled a database containing 14 million records from reimbursement claims for Pap smears, colposcopies, cervical biopsies and surgery, performed between 2002 and 2006. Cervical cancer screening coverage was defined as the proportion of women aged 25-64 that had a Pap smear within the last 3 years. Cervical cancer screening coverage was 61% at national level, for the target population of women between 25 and 64 years old, in the period 2004-2006. Differences between the 3 regions were small, but varied more substantially between provinces. Coverage was 70% for 25-34 year old women, 67% for those aged 35-39 years, and decreased to 44% in the age group of 60-64 years. The median screening interval was 13 months. The screening coverage varied substantially by social category: 40% and 64%, in women categorised as beneficiary or not-beneficiary of increased reimbursement from social insurance, respectively. In the 3-year period 2004-2006, 3.2 million screen tests were done in the target group consisting of 2.8 million women. However, only 1.7 million women got one or more smears and 1.1 million women had no smears, corresponding to an average of 1.88 smears per woman in three years of time. Colposcopy was excessively used (number of Pap smears over colposcopies = 3.2). The proportion of women with a history of conisation or hysterectomy, before the age of 65, was 7% and 19%, respectively. The screening coverage increased slightly from 59% in 2000 to 61% in 2006. The screening intensity remained at a high level, and the number of cytological examinations was theoretically sufficient to cover more than the whole target population.
Progress Toward Measles Elimination - African Region, 2013-2016.
Masresha, Balcha G; Dixon, Meredith G; Kriss, Jennifer L; Katsande, Reggis; Shibeshi, Messeret E; Luce, Richard; Fall, Amadou; Dosseh, Annick R G A; Byabamazima, Charles R; Dabbagh, Alya J; Goodson, James L; Mihigo, Richard
2017-05-05
In 2011, the 46 World Health Organization (WHO) African Region (AFR) member states established a goal of measles elimination* by 2020, by achieving 1) ≥95% coverage of their target populations with the first dose of measles-containing vaccine (MCV1) at national and district levels; 2) ≥95% coverage with measles-containing vaccine (MCV) per district during supplemental immunization activities (SIAs); and 3) confirmed measles incidence of <1 case per 1 million population in all countries (1). Two key surveillance performance indicator targets include 1) investigating ≥2 cases of nonmeasles febrile rash illness per 100,000 population annually, and 2) obtaining a blood specimen from ≥1 suspected measles case in ≥80% of districts annually (2). This report updates the previous report (3) and describes progress toward measles elimination in AFR during 2013-2016. Estimated regional MCV1 coverage † increased from 71% in 2013 to 74% in 2015. § Seven (15%) countries achieved ≥95% MCV1 coverage in 2015. ¶ The number of countries providing a routine second MCV dose (MCV2) increased from 11 (24%) in 2013 to 23 (49%) in 2015. Forty-one (79%) of 52 SIAs** during 2013-2016 reported ≥95% coverage. Both surveillance targets were met in 19 (40%) countries in 2016. Confirmed measles incidence in AFR decreased from 76.3 per 1 million population to 27.9 during 2013-2016. To eliminate measles by 2020, AFR countries and partners need to 1) achieve ≥95% 2-dose MCV coverage through improved immunization services, including second dose (MCV2) introduction; 2) improve SIA quality by preparing 12-15 months in advance, and using readiness, intra-SIA, and post-SIA assessment tools; 3) fully implement elimination-standard surveillance †† ; 4) conduct annual district-level risk assessments; and 5) establish national committees and a regional commission for the verification of measles elimination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherertz, T; Ellis, R; Colussi, V
2014-06-15
Purpose: To evaluate volumetric coverage of a Mick Radionuclear titanium Split-Ring applicator (SRA) with/without interstitial needle compared to an intracavitary Vienna applicator (VA), interstitial-intracavitary VA, and intracavitary ring and tandem applicator (RTA). Methods: A 57 year-old female with FIGO stage IIB cervical carcinoma was treated following chemoradiotherapy (45Gy pelvic and 5.4Gy parametrial boost) with highdose- rate (HDR) brachytherapy to 30Gy in 5 fractions using a SRA. A single interstitial needle was placed using the Ellis Interstitial Cap for the final three fractions to increase coverage of left-sided gross residual disease identified on 3T-MRI. High-risk (HR) clinical target volume (CTV) andmore » intermediate-risk (IR) CTV were defined using axial T2-weighted 2D and 3D MRI sequences (Philips PET/MRI unit). Organs-at-risks (OARs) were delineated on CT. Oncentra planning system was used for treatment optimization satisfying GEC-ESTRO guidelines for target coverage and OAR constraints. Retrospectively, treatment plans (additional 20 plans) were simulated using intracavitary SRA (without needle), intracavitary VA (without needle), interstitial-intracavitary VA, and intracavitary RTA with this same patient case. Plans were optimized for each fraction to maintain coverage to HR-CTV. Results: Interstitial-intracavitary SRA achieved the following combined coverage for external radiation and brachytherapy (EQD2): D90 HR-CTV =94.6Gy; Bladder-2cc =88.9Gy; Rectum-2cc =65.1Gy; Sigmoid-2cc =48.9Gy; Left vaginal wall (VW) =103Gy, Right VW =99.2Gy. Interstitial-intracavitary VA was able to achieve identical D90 HR-CTV =94.6Gy, yet Bladder-2cc =91.9Gy (exceeding GEC-ESTRO recommendations of 2cc<90Gy) and Left VW =120.8Gy and Right VW =115.5Gy. Neither the SRA nor VA without interstitial needle could cover HR-CTV adequately without exceeding dose to Bladder-2cc. Conventional RTA was unable to achieve target coverage for the HR-CTV >80Gy without severely overdosing OARs. Conclusion: The Ellis Interstitial Cap for the SRA offered superior dosimetric coverage as compared to the interstitialintracavitary VA. This represents the first reported use for this devise, and further investigation is warranted.« less
Mbabazi, William; Lako, Anthony K; Ngemera, Daniel; Laku, Richard; Yehia, Mostafah; Nshakira, Nathan
2013-01-01
Since the comprehensive peace agreement was signed in 2005, institutionalization of immunization services in South Sudan remained a priority. Routine administrative reporting systems were established and showed that national coverage rates for DTP-3 rose from 20% in 2002 to 80% in 2011. This survey was conducted as part of an overall review of progress in implementation of the first EPI Multi-Year Plan for South Sudan 2007-2011. This report provides maiden community coverage estimates for immunization. A cross sectional community survey was conducted between January and May 2012. Ten cluster surveys were conducted to generate state-specific coverage estimates. The WHO 30x7 cluster sampling method was employed. Data was collected using pre-tested, interviewer guided, structured questionnaires through house to house visits. The fully immunized children were 7.3%. Coverage for specific antigens were; BCG (28.3%), DTP-1(25.9%), DTP-3 (22.0%), Measles (16.8%). The drop-out rate between the first and third doses of DTP was 21.3%. Immunization coverage estimates based on card and history were higher, at 45.7% for DTP-3, 45.8% for MCV and 32.2% for full immunization. Majority of immunizations (80.8%) were received at health facilities compared to community service points (19.2%). The major reason for missed immunizations was inadequate information (41.1%). The proportion of card-verified, fully vaccinated among children aged 12-23 months is very low at 7.3%. Future efforts to improve vaccination quality and coverage should prioritize training of vaccinators and program communication to levels equivalent or higher than investments in EPI cold chain systems since 2007.
Mbabazi, William; Lako, Anthony K; Ngemera, Daniel; Laku, Richard; Yehia, Mostafah; Nshakira, Nathan
2013-01-01
Introduction Since the comprehensive peace agreement was signed in 2005, institutionalization of immunization services in South Sudan remained a priority. Routine administrative reporting systems were established and showed that national coverage rates for DTP-3 rose from 20% in 2002 to 80% in 2011. This survey was conducted as part of an overall review of progress in implementation of the first EPI Multi-Year Plan for South Sudan 2007-2011. This report provides maiden community coverage estimates for immunization. Methods A cross sectional community survey was conducted between January and May 2012. Ten cluster surveys were conducted to generate state-specific coverage estimates. The WHO 30x7 cluster sampling method was employed. Data was collected using pre-tested, interviewer guided, structured questionnaires through house to house visits. Results The fully immunized children were 7.3%. Coverage for specific antigens were; BCG (28.3%), DTP-1(25.9%), DTP-3 (22.0%), Measles (16.8%). The drop-out rate between the first and third doses of DTP was 21.3%. Immunization coverage estimates based on card and history were higher, at 45.7% for DTP-3, 45.8% for MCV and 32.2% for full immunization. Majority of immunizations (80.8%) were received at health facilities compared to community service points (19.2%). The major reason for missed immunizations was inadequate information (41.1%). Conclusion The proportion of card-verified, fully vaccinated among children aged 12-23 months is very low at 7.3%. Future efforts to improve vaccination quality and coverage should prioritize training of vaccinators and program communication to levels equivalent or higher than investments in EPI cold chain systems since 2007. PMID:24876899
Coverage Gains After the Affordable Care Act Among the Uninsured in Minnesota.
Call, Kathleen Thiede; Lukanen, Elizabeth; Spencer, Donna; Alarcón, Giovann; Kemmick Pintor, Jessie; Baines Simon, Alisha; Gildemeister, Stefan
2015-11-01
We determined whether and how Minnesotans who were uninsured in 2013 gained health insurance coverage in 2014, 1 year after the Affordable Care Act (ACA) expanded Medicaid coverage and enrollment. Insurance status and enrollment experiences came from the Minnesota Health Insurance Transitions Study (MH-HITS), a follow-up telephone survey of children and adults in Minnesota who had no health insurance in the fall of 2013. ACA had a tempered success in Minnesota. Outreach and enrollment efforts were effective; one half of those previously uninsured gained coverage, although many reported difficulty signing up (nearly 62%). Of the previously uninsured who gained coverage, 44% obtained their coverage through MNsure, Minnesota's insurance marketplace. Most of those who remained uninsured heard of MNsure and went to the Web site. Many still struggled with the enrollment process or reported being deterred by the cost of coverage. Targeting outreach, simplifying the enrollment process, focusing on affordability, and continuing funding for in-person assistance will be important in the future.
Coverage Gains After the Affordable Care Act Among the Uninsured in Minnesota
Lukanen, Elizabeth; Spencer, Donna; Alarcón, Giovann; Kemmick Pintor, Jessie; Baines Simon, Alisha; Gildemeister, Stefan
2015-01-01
Objectives. We determined whether and how Minnesotans who were uninsured in 2013 gained health insurance coverage in 2014, 1 year after the Affordable Care Act (ACA) expanded Medicaid coverage and enrollment. Methods. Insurance status and enrollment experiences came from the Minnesota Health Insurance Transitions Study (MH-HITS), a follow-up telephone survey of children and adults in Minnesota who had no health insurance in the fall of 2013. Results. ACA had a tempered success in Minnesota. Outreach and enrollment efforts were effective; one half of those previously uninsured gained coverage, although many reported difficulty signing up (nearly 62%). Of the previously uninsured who gained coverage, 44% obtained their coverage through MNsure, Minnesota’s insurance marketplace. Most of those who remained uninsured heard of MNsure and went to the Web site. Many still struggled with the enrollment process or reported being deterred by the cost of coverage. Conclusions. Targeting outreach, simplifying the enrollment process, focusing on affordability, and continuing funding for in-person assistance will be important in the future. PMID:26447912
DNA barcoding in the media: does coverage of cool science reflect its social context?
Geary, Janis; Camicioli, Emma; Bubela, Tania
2016-09-01
Paul Hebert and colleagues first described DNA barcoding in 2003, which led to international efforts to promote and coordinate its use. Since its inception, DNA barcoding has generated considerable media coverage. We analysed whether this coverage reflected both the scientific and social mandates of international barcoding organizations. We searched newspaper databases to identify 900 English-language articles from 2003 to 2013. Coverage of the science of DNA barcoding was highly positive but lacked context for key topics. Coverage omissions pose challenges for public understanding of the science and applications of DNA barcoding; these included coverage of governance structures and issues related to the sharing of genetic resources across national borders. Our analysis provided insight into how barcoding communication efforts have translated into media coverage; more targeted communication efforts may focus media attention on previously omitted, but important topics. Our analysis is timely as the DNA barcoding community works to establish the International Society for the Barcode of Life.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, I; Algan, O; Ahmad, S
Purpose: To model patient motion and produce four-dimensional (4D) optimized dose distributions that consider motion-artifacts in the dose calculation during the treatment planning process. Methods: An algorithm for dose calculation is developed where patient motion is considered in dose calculation at the stage of the treatment planning. First, optimal dose distributions are calculated for the stationary target volume where the dose distributions are optimized considering intensity-modulated radiation therapy (IMRT). Second, a convolution-kernel is produced from the best-fitting curve which matches the motion trajectory of the patient. Third, the motion kernel is deconvolved with the initial dose distribution optimized for themore » stationary target to produce a dose distribution that is optimized in four-dimensions. This algorithm is tested with measured doses using a mobile phantom that moves with controlled motion patterns. Results: A motion-optimized dose distribution is obtained from the initial dose distribution of the stationary target by deconvolution with the motion-kernel of the mobile target. This motion-optimized dose distribution is equivalent to that optimized for the stationary target using IMRT. The motion-optimized and measured dose distributions are tested with the gamma index with a passing rate of >95% considering 3% dose-difference and 3mm distance-to-agreement. If the dose delivery per beam takes place over several respiratory cycles, then the spread-out of the dose distributions is only dependent on the motion amplitude and not affected by motion frequency and phase. This algorithm is limited to motion amplitudes that are smaller than the length of the target along the direction of motion. Conclusion: An algorithm is developed to optimize dose in 4D. Besides IMRT that provides optimal dose coverage for a stationary target, it extends dose optimization to 4D considering target motion. This algorithm provides alternative to motion management techniques such as beam-gating or breath-holding and has potential applications in adaptive radiation therapy.« less
Radiation therapy for breast cancer: Literature review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balaji, Karunakaran, E-mail: karthik.balaji85@gmail.com; School of Advanced Sciences, VIT University, Vellore; Subramanian, Balaji
Concave shape with variable size target volume makes treatment planning for the breast/chest wall a challenge. Conventional techniques used for the breast/chest wall cancer treatment provided better sparing of organs at risk (OARs), with poor conformity and uniformity to the target volume. Advanced technologies such as intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) improve the target coverage at the cost of higher low dose volumes to OARs. Novel hybrid techniques present promising results in breast/chest wall irradiation in terms of target coverage as well as OARs sparing. Several published data compared these technologies for the benefit ofmore » the breast/chest wall with or without nodal volumes. The aim of this article is to review relevant data and identify the scope for further research in developing optimal treatment plan for breast/chest wall cancer treatment.« less
Ships and Maritime Targets Observation Campaigns Using Available C- and X-Band SAR Satellite
NASA Astrophysics Data System (ADS)
Velotto, Domenico; Bentes, Carlos; Lehner, Susanne
2015-04-01
Obviously, radar resolution and swath width are two very important factors when it comes to synthetic aperture radar (SAR) maritime targets detections. The dilemma of using single polarization SAR imagery with higher resolution and coverage or quad- (or dual- polarimetric) imagery with its richness of information, is still unsolved when it comes to this application.In the framework of ESA project MARISS and EU project DOLPHIN, in situ campaigns aimed at solving this dilemma have been carried out. Single and multi- polarimetric SAR data acquired by TerraSAR-X, RADARSAT-2 and COSMO-SkyMed have been acquired with close time gaps and partial coverage overlap. In this way several moving and non-moving maritime targets have been imaged with different polarization, geometry and working frequency. Available ground truth reports provided by Automatic Identification System (AIS) data, nautical chart and wind farm location are used to validate the different types of maritime targets.
Targeted Help for Spoken Dialogue Systems: Intelligent Feedback Improves Naive Users' Performance
NASA Technical Reports Server (NTRS)
Hockey, Beth Ann; Lemon, Oliver; Campana, Ellen; Hiatt, Laura; Aist, Gregory; Hieronymous, Jim; Gruenstein, Alexander; Dowding, John
2003-01-01
We present experimental evidence that providing naive users of a spoken dialogue system with immediate help messages related to their out-of-coverage utterances improves their success in using the system. A grammar-based recognizer and a Statistical Language Model (SLM) recognizer are run simultaneously. If the grammar-based recognizer suceeds, the less accurate SLM recognizer hypothesis is not used. When the grammar-based recognizer fails and the SLM recognizer produces a recognition hypothesis, this result is used by the Targeted Help agent to give the user feed-back on what was recognized, a diagnosis of what was problematic about the utterance, and a related in-coverage example. The in-coverage example is intended to encourage alignment between user inputs and the language model of the system. We report on controlled experiments on a spoken dialogue system for command and control of a simulated robotic helicopter.
Lin, Jing; Pramono, Zacharias Aloysius Dwi; Maurer-Stroh, Sebastian
2016-01-01
The multiple circulating human influenza A virus subtypes coupled with the perpetual genomic mutations and segment reassortment events challenge the development of effective therapeutics. The capacity to drug most RNAs motivates the investigation on viral RNA targets. 123,060 segment sequences from 35,938 strains of the most prevalent subtypes also infecting humans–H1N1, 2009 pandemic H1N1, H3N2, H5N1 and H7N9, were used to identify 1,183 conserved RNA target sequences (≥15-mer) in the internal segments. 100% theoretical coverage in simultaneous heterosubtypic targeting is achieved by pairing specific sequences from the same segment (“Duals”) or from two segments (“Doubles”); 1,662 Duals and 28,463 Doubles identified. By combining specific Duals and/or Doubles to form a target graph wherein an edge connecting two vertices (target sequences) represents a Dual or Double, it is possible to hedge against antiviral resistance besides maintaining 100% heterosubtypic coverage. To evaluate the hedging potential, we define the hedge-factor as the minimum number of resistant target sequences that will render the graph to become resistant i.e. eliminate all the edges therein; a target sequence or a graph is considered resistant when it cannot achieve 100% heterosubtypic coverage. In an n-vertices graph (n ≥ 3), the hedge-factor is maximal (= n– 1) when it is a complete graph i.e. every distinct pair in a graph is either a Dual or Double. Computational analyses uncover an extensive number of complete graphs of different sizes. Monte Carlo simulations show that the mutation counts and time elapsed for a target graph to become resistant increase with the hedge-factor. Incidentally, target sequences which were reported to reduce virus titre in experiments are included in our target graphs. The identity of target sequence pairs for heterosubtypic targeting and their combinations for hedging antiviral resistance are useful toolkits to construct target graphs for different therapeutic objectives. PMID:26771381
Patient-specific dose estimation for pediatric abdomen-pelvis CT
NASA Astrophysics Data System (ADS)
Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.
2009-02-01
The purpose of this study is to develop a method for estimating patient-specific dose from abdomen-pelvis CT examinations and to investigate dose variation across patients in the same weight group. Our study consisted of seven pediatric patients in the same weight/protocol group, for whom full-body computer models were previously created based on the patients' CT data obtained for clinical indications. Organ and effective dose of these patients from an abdomen-pelvis scan protocol (LightSpeed VCT scanner, 120-kVp, 85-90 mA, 0.4-s gantry rotation period, 1.375-pitch, 40-mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated for the same CT system. The seven patients had effective dose of 2.4-2.8 mSv, corresponding to normalized effective dose of 6.6-8.3 mSv/100mAs (coefficient of variation: 7.6%). Dose variations across the patients were small for large organs in the scan coverage (mean: 6.6%; range: 4.9%-9.2%), larger for small organs in the scan coverage (mean: 10.3%; range: 1.4%-15.6%), and the largest for organs partially or completely outside the scan coverage (mean: 14.8%; range: 5.7%-27.7%). Normalized effective dose correlated strongly with body weight (correlation coefficient: r = -0.94). Normalized dose to the kidney and the adrenal gland correlated strongly with mid-liver equivalent diameter (kidney: r = -0.97; adrenal glands: r = -0.98). Normalized dose to the small intestine correlated strongly with mid-intestine equivalent diameter (r = -0.97). These strong correlations suggest that patient-specific dose may be estimated for any other child in the same size group who undergoes the abdomen-pelvis scan.
Physics-Aware Informative Coverage Planning for Autonomous Vehicles
2014-06-01
environment and find the optimal path connecting fixed nodes, which is equivalent to solving the Traveling Salesman Problem (TSP). While TSP is an NP...intended for application to USV harbor patrolling, it is applicable to many different domains. The problem of traveling over an area and gathering...environment. I. INTRODUCTION There are many applications that need persistent monitor- ing of a given area, requiring repeated travel over the area to
A presentation of the differences between the sheep and goat genetic maps
2005-01-01
The current autosomal version (4.2) of the sheep genetic map comprises 1175 loci and spans ~3540 cM. This corresponds to almost complete coverage of the sheep genome. Each chromosome is represented by a single linkage group, with the largest gap between adjacent loci being 19.8 cM. In contrast the 1998 goat genetic map (the most recently published) is much less well developed spanning 2737 cM and comprising only 307 loci. Only one of the goat chromosomes appears to have complete coverage (chromosome 27), and 16 of the chromosomes are comprised of two or more linkage groups, or a linkage group and one or more unlinked markers. The two maps share 218 loci, and the maps have been aligned using the shared loci as reference points. Overall there is good agreement between the maps in terms of homologous loci mapping to equivalent chromosomes in the two species, with only four markers mapping to non-equivalent chromosomes. However, there are lots of inversions in locus order between the sheep and goat chromosomes. Whilst some of these differences in locus order may be genuine, the majority are likely to be a consequence of the paucity of genetic information for the goat map. PMID:15601590
ERIC Educational Resources Information Center
Lovett, Sadie; Rehfeldt, Ruth Anne; Garcia, Yors; Dunning, Johnna
2011-01-01
This study compared the effects of a computer-based stimulus equivalence protocol to a traditional lecture format in teaching single-subject experimental design concepts to undergraduate students. Participants were assigned to either an equivalence or a lecture group, and performance on a paper-and-pencil test that targeted relations among the…
Cho, Jungwoo; You, Myoungsoon; Yoon, Yoonjin
2017-01-01
In highly urbanized area where traffic condition fluctuates constantly, transportation infrastructure is one of the major contributing factors to Emergency Medical Service (EMS) availability and patient outcome. In this paper, we assess the impact of traffic fluctuation to the EMS first response availability in urban area, by evaluating the k-minute coverage under 21 traffic scenarios. The set of traffic scenarios represents the time-of-day and day-of-week effects, and is generated by combining road link speed information from multiple historical speed databases. In addition to the k-minute area coverage calculation, the k-minute population coverage is also evaluated for every 100m by 100m grid that partitions the case study area of Seoul, South Korea. In the baseline case of traveling at the speed limit, both the area and population coverage reached nearly 100% when compared to the five-minute travel time national target. Employing the proposed LoST (Loss of Serviceability due to Traffic) index, which measures coverage reduction in percentage compared to the baseline case, we find that the citywide average LoST for area and population coverage are similar at 34.2% and 33.8%. However, district-wise analysis reveals that such reduction varies significantly by district, and the magnitude of area and population coverage reduction is not always proportional. We conclude that the effect of traffic variation is significant to successful urban EMS first response performance, and regional variation is evident among local districts. Complexity in the urban environment requires a more adaptive approach in public health resource management and EMS performance target determination.
Chapman, Audrey R
2016-12-15
The UN's Sustainable Development Goals (SDGs), adopted in September 2015, include a comprehensive health goal, "to ensure healthy lives and promote well-being at all ages." The health goal (SDG 3) has nine substantive targets and four additional targets which are identified as a means of implementation. One of these commitments, to achieve universal health coverage (UHC), has been acknowledged as central to the achievement of all of the other health targets. As defined in the SDGs, UHC includes financial risk protection, access to quality essential health-care services, and access to safe, effective, quality and affordable essential medicines and vaccines for all. This article evaluates the extent to which the UHC target in the SDGs conforms with the requirements of the right to health enumerated in the International Covenant on Economic, Social and Cultural Rights, the Convention on the Rights of the Child, and other international human rights instruments and interpreted by international human rights bodies. It does so as a means to identify strengths and weaknesses in the framing of the UHC target that are likely to affect its implementation. While UHC as defined in the SDGs overlaps with human rights standards, there are important human rights omissions that will likely weaken the implementation and reduce the potential benefits of the UHC target. The most important of these is the failure to confer priority to providing access to health services to poor and disadvantaged communities in the process of expanding health coverage and in determining which health services to provide. Unless the furthest behind are given priority and strategies adopted to secure their participation in the development of national health plans, the SDGs, like the MDGs, are likely to leave the most disadvantaged and vulnerable communities behind.
Alberti, K P; Guthmann, J P; Fermon, F; Nargaye, K D; Grais, R F
2008-03-01
Inadequate evaluation of vaccine coverage after mass vaccination campaigns, such as used in national measles control programmes, can lead to inappropriate public health responses. Overestimation of vaccination coverage may leave populations at risk, whilst underestimation can lead to unnecessary catch-up campaigns. The problem is more complex in large urban areas where vaccination coverage may be heterogeneous and the programme may have to be fine-tuned at the level of geographic subunits. Lack of accurate population figures in many contexts further complicates accurate vaccination coverage estimates. During the evaluation of a mass vaccination campaign carried out in N'Djamena, the capital of Chad, Lot Quality Assurance Sampling was used to estimate vaccination coverage. Using this method, vaccination coverage could be evaluated within smaller geographic areas of the city as well as for the entire city. Despite the lack of accurate population data by neighbourhood, the results of the survey showed heterogeneity of vaccination coverage within the city. These differences would not have been identified using a more traditional method. The results can be used to target areas of low vaccination coverage during follow-up vaccination activities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lens, Eelco, E-mail: e.lens@amc.uva.nl; Horst, Astrid van der; Versteijne, Eva
2015-07-01
Purpose: The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials: For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dosemore » distribution was analyzed; PTV coverage was required to be at least V{sub 95%} >98%. In addition, the change in PTV size and the changes in V{sub 10Gy}, V{sub 20Gy}, V{sub 30Gy}, V{sub 40Gy}, D{sub mean} and D{sub 2cc} for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results: Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D{sub 2cc} of the duodenum, improved significantly (P≤.002). Conclusions: By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.« less
Vila, Andrew; Tallman, Keri A.; Jacobs, Aaron T.; Liebler, Daniel C.; Porter, Ned A.; Marnett, Lawrence J.
2009-01-01
Polyunsaturated fatty acids (PUFA) are primary targets of free radical damage during oxidative stress. Diffusible electrophilic α, β-unsaturated aldehydes, such as 4-hydroxynonenal (HNE), have been shown to modify proteins that mediate cell signaling (e.g. IKK and Keap1) and alter gene expression pathways responsible for inducing antioxidant genes, heat shock proteins, and the DNA damage response. To fully understand cellular responses to HNE, it is important to determine its protein targets in an unbiased fashion. This requires a strategy for detecting and isolating HNE-modified proteins regardless of the nature of the chemical linkage between HNE and its targets. Azido or alkynyl derivatives of HNE were synthesized and demonstrated to be equivalent to HNE in their ability to induce heme oxygenase induction and induce apoptosis in colon cancer (RKO) cells. Cells exposed to the tagged HNE derivatives were lysed and exposed to reagents to effect Staudinger ligation or copper-catalyzed Huisgen 1,3 dipolar cycloaddition reaction (click chemistry) to conjugate HNE-adducted proteins with biotin for subsequent affinity purification. Both strategies yielded efficient biotinylation of tagged HNE-protein conjugates but click chemistry was found to be superior for recovery of biotinylated proteins from streptavidin-coated beads. Biotinylated proteins were detected in lysates from RKO cell incubations with azido-HNE at concentrations as low as 1 μM. These proteins were affinity purified with streptavidin beads and proteomic analysis was performed by linear ion trap mass spectrometry. Proteomic analysis revealed a dose-dependent increase in labeled proteins with increased sequence coverage at higher concentrations. Several proteins involved in stress signaling (heat shock proteins 70 and 90, and the 78-kDa glucose-regulated protein) were selectively adducted by azido- and alkynyl-HNE. The use of azido and alkynyl derivatives in conjunction with click chemistry appears to be a valuable approach for the identification of the protein targets of HNE. PMID:18232660
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, J; Eldib, A; Ma, C
2016-06-15
Purpose: Dose-volume-histogram (DVH) is widely used for plan evaluation in radiation treatment. The concept of dose-mass-histogram (DMH) is expected to provide a more representative description as it accounts for heterogeneity in tissue density. This study is intended to assess the difference between DVH and DMH for evaluating treatment planning quality. Methods: 12 lung cancer treatment plans were exported from the treatment planning system. DVHs for the planning target volume (PTV), the normal lung and other structures of interest were calculated. DMHs were calculated in a similar way as DVHs expect that the voxel density converted from the CT number wasmore » used in tallying the dose histogram bins. The equivalent uniform dose (EUD) was calculated based on voxel volume and mass, respectively. The normal tissue complication probability (NTCP) in relation to the EUD was calculated for the normal lung to provide quantitative comparison of DVHs and DMHs for evaluating the radiobiological effect. Results: Large differences were observed between DVHs and DMHs for lungs and PTVs. For PTVs with dense tumor cores, DMHs are higher than DVHs due to larger mass weighing in the high dose conformal core regions. For the normal lungs, DMHs can either be higher or lower than DVHs depending on the target location within the lung. When the target is close to the lower lung, DMHs show higher values than DVHs because the lower lung has higher density than the central portion or the upper lung. DMHs are lower than DVHs for targets in the upper lung. The calculated NTCPs showed a large range of difference between DVHs and DMHs. Conclusion: The heterogeneity of lung can be well considered using DMH for evaluating target coverage and normal lung pneumonitis. Further studies are warranted to quantify the benefits of DMH over DVH for plan quality evaluation.« less
Stenberg, Karin; Hanssen, Odd; Edejer, Tessa Tan-Torres; Bertram, Melanie; Brindley, Callum; Meshreky, Andreia; Rosen, James E; Stover, John; Verboom, Paul; Sanders, Rachel; Soucat, Agnès
2017-09-01
The ambitious development agenda of the Sustainable Development Goals (SDGs) requires substantial investments across several sectors, including for SDG 3 (healthy lives and wellbeing). No estimates of the additional resources needed to strengthen comprehensive health service delivery towards the attainment of SDG 3 and universal health coverage in low-income and middle-income countries have been published. We developed a framework for health systems strengthening, within which population-level and individual-level health service coverage is gradually scaled up over time. We developed projections for 67 low-income and middle-income countries from 2016 to 2030, representing 95% of the total population in low-income and middle-income countries. We considered four service delivery platforms, and modelled two scenarios with differing levels of ambition: a progress scenario, in which countries' advancement towards global targets is constrained by their health system's assumed absorptive capacity, and an ambitious scenario, in which most countries attain the global targets. We estimated the associated costs and health effects, including reduced prevalence of illness, lives saved, and increases in life expectancy. We projected available funding by country and year, taking into account economic growth and anticipated allocation towards the health sector, to allow for an analysis of affordability and financial sustainability. We estimate that an additional $274 billion spending on health is needed per year by 2030 to make progress towards the SDG 3 targets (progress scenario), whereas US$371 billion would be needed to reach health system targets in the ambitious scenario-the equivalent of an additional $41 (range 15-102) or $58 (22-167) per person, respectively, by the final years of scale-up. In the ambitious scenario, total health-care spending would increase to a population-weighted mean of $271 per person (range 74-984) across country contexts, and the share of gross domestic product spent on health would increase to a mean of 7·5% (2·1-20·5). Around 75% of costs are for health systems, with health workforce and infrastructure (including medical equipment) as the main cost drivers. Despite projected increases in health spending, a financing gap of $20-54 billion per year is projected. Should funds be made available and used as planned, the ambitious scenario would save 97 million lives and significantly increase life expectancy by 3·1-8·4 years, depending on the country profile. All countries will need to strengthen investments in health systems to expand service provision in order to reach SDG 3 health targets, but even the poorest can reach some level of universality. In view of anticipated resource constraints, each country will need to prioritise equitably, plan strategically, and cost realistically its own path towards SDG 3 and universal health coverage. WHO. Copyright © 2017 World Health Organization; licensee Elsevier. This is an Open Access article published under the CC BY 3.0 IGO license which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. In any use of this article, there should be no suggestion that WHO endorses any specific organisation, products or services. The use of the WHO logo is not permitted. This notice should be preserved along with the article's original URL.
Ranger, A; Dunlop, A; Hutchinson, K; Convery, H; Maclennan, M K; Chantler, H; Twyman, N; Rose, C; McQuaid, D; Amos, R A; Griffin, C; deSouza, N M; Donovan, E; Harris, E; Coles, C E; Kirby, A
2018-06-01
Radiotherapy target volumes in early breast cancer treatment increasingly include the internal mammary chain (IMC). In order to maximise survival benefits of IMC radiotherapy, doses to the heart and lung should be minimised. This dosimetry study compared the ability of three-dimensional conformal radiotherapy, arc therapy and proton beam therapy (PBT) techniques with and without breath-hold to achieve target volume constraints while minimising dose to organs at risk (OARs). In 14 patients' datasets, seven IMC radiotherapy techniques were compared: wide tangent (WT) three-dimensional conformal radiotherapy, volumetric-modulated arc therapy (VMAT) and PBT, each in voluntary deep inspiratory breath-hold (vDIBH) and free breathing (FB), and tomotherapy in FB only. Target volume coverage and OAR doses were measured for each technique. These were compared using a one-way ANOVA with all pairwise comparisons tested using Bonferroni's multiple comparisons test, with adjusted P-values ≤ 0.05 indicating statistical significance. One hundred per cent of WT(vDIBH), 43% of WT(FB), 100% of VMAT(vDIBH), 86% of VMAT(FB), 100% of tomotherapy FB and 100% of PBT plans in vDIBH and FB passed all mandatory constraints. However, coverage of the IMC with 90% of the prescribed dose was significantly better than all other techniques using VMAT(vDIBH), PBT(vDIBH) and PBT(FB) (mean IMC coverage ± 1 standard deviation = 96.0% ± 4.3, 99.8% ± 0.3 and 99.0% ± 0.2, respectively). The mean heart dose was significantly reduced in vDIBH compared with FB for both the WT (P < 0.0001) and VMAT (P < 0.0001) techniques. There was no advantage in target volume coverage or OAR doses for PBT(vDIBH) compared with PBT(FB). Simple WT radiotherapy delivered in vDIBH achieves satisfactory coverage of the IMC while meeting heart and lung dose constraints. However, where higher isodose coverage is required, VMAT(vDIBH) is the optimal photon technique. The lowest OAR doses are achieved by PBT, in which the use of vDIBH does not improve dose statistics. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, Pretesh R., E-mail: patel073@mc.duke.edu; Yoo, Sua; Broadwater, Gloria
Purpose: To assess the impact of increasing experience with intensity-modulated radiation therapy (IMRT) after extrapleural pneumonectomy (EPP) for malignant pleural mesothelioma (MPM). Methods and Materials: The records of all patients who received IMRT following EPP at Duke University Medical Center between 2005 and 2010 were reviewed. Target volumes included the preoperative extent of the pleural space, chest wall incisions, involved nodal stations, and a boost to close/positive surgical margins if applicable. Patients were typically treated with 9-11 beams with gantry angles, collimator rotations, and beam apertures manually fixed to avoid the contalateral lung and to optimize target coverage. Toxicity wasmore » graded retrospectively using National Cancer Institute common toxicity criteria version 4.0. Target coverage and contralateral lung irradiation were evaluated over time by using linear regression. Local control, disease-free survival, and overall survival rates were estimated using the Kaplan-Meier method. Results: Thirty patients received IMRT following EPP; 21 patients also received systemic chemotherapy. Median follow-up was 15 months. The median dose prescribed to the entire ipsilateral hemithorax was 45 Gy (range, 40-50.4 Gy) with a boost of 8-25 Gy in 9 patients. Median survival was 23.2 months. Two-year local control, disease-free survival, and overall survival rates were 47%, 34%, and 50%, respectively. Increasing experience planning MPM cases was associated with improved coverage of planning target volumes (P=.04). Similarly, mean lung dose (P<.01) and lung V5 (volume receiving 5 Gy or more; P<.01) values decreased with increasing experience. Lung toxicity developed after IMRT in 4 (13%) patients at a median of 2.2 months after RT (three grade 3-4 and one grade 5). Lung toxicity developed in 4 of the initial 15 patients vs none of the last 15 patients treated. Conclusions: With increasing experience, target volume coverage improved and dose to the contralateral lung decreased. Rates of pulmonary toxicity were relatively low. However, both local and distant control rates remained suboptimal.« less
Parker, Lucy A; Rumunu, John; Jamet, Christine; Kenyi, Yona; Lino, Richard Laku; Wamala, Joseph F; Mpairwe, Allan M; Muller, Vincent; Llosa, Augusto E; Uzzeni, Florent; Luquero, Francisco J; Ciglenecki, Iza; Azman, Andrew S
2017-06-01
In June 2015, a cholera outbreak was declared in Juba, South Sudan. In addition to standard outbreak control measures, oral cholera vaccine (OCV) was proposed. As sufficient doses to cover the at-risk population were unavailable, a campaign using half the standard dosing regimen (one-dose) targeted high-risk neighborhoods and groups including neighbors of suspected cases. Here we report the operational details of this first public health use of a single-dose regimen of OCV and illustrate the feasibility of conducting highly targeted vaccination campaigns in an urban area. Neighborhoods of the city were prioritized for vaccination based on cumulative attack rates, active transmission and local knowledge of known cholera risk factors. OCV was offered to all persons older than 12 months at 20 fixed sites and to select groups, including neighbors of cholera cases after the main campaign ('case-triggered' interventions), through mobile teams. Vaccination coverage was estimated by multi-stage surveys using spatial sampling techniques. 162,377 individuals received a single-dose of OCV in the targeted neighborhoods. In these neighborhoods vaccine coverage was 68.8% (95% Confidence Interval (CI), 64.0-73.7) and was highest among children ages 5-14 years (90.0%, 95% CI 85.7-94.3), with adult men being less likely to be vaccinated than adult women (Relative Risk 0.81, 95% CI: 0.68-0.96). In the case-triggered interventions, each lasting 1-2 days, coverage varied (range: 30-87%) with an average of 51.0% (95% CI 41.7-60.3). Vaccine supply constraints and the complex realities where cholera outbreaks occur may warrant the use of flexible alternative vaccination strategies, including highly-targeted vaccination campaigns and single-dose regimens. We showed that such campaigns are feasible. Additional work is needed to understand how and when to use different strategies to best protect populations against epidemic cholera.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moignier, Alexandra, E-mail: alexandra-moignier@uiowa.edu; Gelover, Edgar; Wang, Dongxu
Purpose: To quantify the dosimetric benefit of using a dynamic collimation system (DCS) for penumbra reduction during the treatment of brain tumors by pencil beam scanning proton therapy (PBS PT). Methods and Materials: Collimated and uncollimated brain treatment plans were created for 5 patients previously treated with PBS PT and retrospectively enrolled in an institutional review board–approved study. The in-house treatment planning system, RDX, was used to generate the plans because it is capable of modeling both collimated and uncollimated beamlets. The clinically delivered plans were reproduced with uncollimated plans in terms of target coverage and organ at risk (OAR) sparingmore » to ensure a clinically relevant starting point, and collimated plans were generated to improve the OAR sparing while maintaining target coverage. Physical and biological comparison metrics, such as dose distribution conformity, mean and maximum doses, normal tissue complication probability, and risk of secondary brain cancer, were used to evaluate the plans. Results: The DCS systematically improved the dose distribution conformity while preserving the target coverage. The average reduction of the mean dose to the 10-mm ring surrounding the target and the healthy brain were 13.7% (95% confidence interval [CI] 11.6%-15.7%; P<.0001) and 25.1% (95% CI 16.8%-33.4%; P<.001), respectively. This yielded an average reduction of 24.8% (95% CI 0.8%-48.8%; P<.05) for the brain necrosis normal tissue complication probability using the Flickinger model, and 25.1% (95% CI 16.8%-33.4%; P<.001) for the risk of secondary brain cancer. A general improvement of the OAR sparing was also observed. Conclusion: The lateral penumbra reduction afforded by the DCS increases the normal tissue sparing capabilities of PBS PT for brain cancer treatment while preserving target coverage.« less
Accurate and exact CNV identification from targeted high-throughput sequence data.
Nord, Alex S; Lee, Ming; King, Mary-Claire; Walsh, Tom
2011-04-12
Massively parallel sequencing of barcoded DNA samples significantly increases screening efficiency for clinically important genes. Short read aligners are well suited to single nucleotide and indel detection. However, methods for CNV detection from targeted enrichment are lacking. We present a method combining coverage with map information for the identification of deletions and duplications in targeted sequence data. Sequencing data is first scanned for gains and losses using a comparison of normalized coverage data between samples. CNV calls are confirmed by testing for a signature of sequences that span the CNV breakpoint. With our method, CNVs can be identified regardless of whether breakpoints are within regions targeted for sequencing. For CNVs where at least one breakpoint is within targeted sequence, exact CNV breakpoints can be identified. In a test data set of 96 subjects sequenced across ~1 Mb genomic sequence using multiplexing technology, our method detected mutations as small as 31 bp, predicted quantitative copy count, and had a low false-positive rate. Application of this method allows for identification of gains and losses in targeted sequence data, providing comprehensive mutation screening when combined with a short read aligner.
SU-F-T-443: Quantification of Dosimetric Effects of Dental Metallic Implant On VMAT Plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, C; Jiang, W; Feng, Y
Purpose: To evaluate the dosimetric impact of metallic implant that correlates with the size of targets and metallic implants and distance in between on volumetric-modulated arc therapy (VMAT) plans for head and neck (H&N) cancer patients with dental metallic implant. Methods: CT images of H&N cancer patients with dental metallic implant were used. Target volumes with different sizes and locations were contoured. Metal artifact regions excluding surrounding critical organs were outlined and assigned with CT numbers close to water (0HU). VMAT plans with half-arc, one-full-arc and two-full-arcs were constructed and same plans were applied to structure sets with and withoutmore » CT number assignment of metal artifact regions and compared. D95% was utilized to investigate PTV dose coverage and SNC Patient− Software was used for the analysis of dose distribution difference slice by slice. Results: For different targets sizes, variation of PTV dose coverage (Delta-D95%) with and without CT number replacement reduced with larger target volume for all half-arc, one-arc and two-arc VMAT plans even though there were no clinically significant differences. Additionally, there were no significant variations of the maximum percent difference (max.%diff) of dose distribution. With regard to the target location, Delta-D95% and max. %diff dropped with increasing distance between target and metallic implant. Furthermore, half-arc plans showed greater impact than one-arc plans, and two-arc plans had smallest influence for PTV dose coverage and dose distribution. Conclusion: The target size has less correlation of doseimetric impact than the target location relative to metallic implants. Plans with more arcs alleviate the dosimetric effect of metal artifact because of less contribution to the target dose from beams going through the regions with metallic artifacts. Incorrect CT number causes inaccurate dose distribution, therefore appropriately overwriting metallic artifact regions with reasonable CT numbers is recommended. More patient data are collected and under further analysis.« less
Cost variability of suggested generic treatment alternatives under the Medicare Part D benefit.
Patel, Rajul A; Walberg, Mark P; Tong, Emily; Tan, Florence; Rummel, Ashley E; Woelfel, Joseph A; Carr-Lopez, Sian M; Galal, Suzanne M
2014-03-01
The substitution of generic treatment alternatives for brand-name drugs is a strategy that can help lower Medicare beneficiary out-of-pocket costs. Beginning in 2011, Medicare beneficiaries reaching the coverage gap received a 50% discount on the full drug cost of brand-name medications and a 7% discount on generic medications filled during the gap. This discount will increase until 2020, when beneficiaries will be responsible for 25% of total drug costs during the coverage gap. To examine the cost variability of brand and generic drugs within 4 therapeutic classes before and during the coverage gap for each 2011 California stand-alone prescription drug plan (PDP) and prospective coverage gap costs in 2020 to determine the effects on beneficiary out-of-pocket drug costs. Equivalent doses of brand and generic drugs in the following 4 pharmacological classes were examined: angiotensin II receptor blockers (ARBs), bisphosphonates, HMG-CoA reductase inhibitors (statins), and proton pump inhibitors (PPIs). The full drug cost and patient copay/coinsurance amounts during initial coverage and the coverage gap of each drug was recorded based on information retrieved from the Medicare website. These drug cost data were recorded for 28 California PDPs. The highest cost difference between a brand medication and a Centers for Medicare Medicaid Services (CMS)-suggested generic treatment alternative varied between $110.53 and $195.49 at full cost and between $51.37 and $82.35 in the coverage gap. The lowest cost difference varied between $38.45 and $76.93 at full cost and between -$4.11 and $18.52 during the gap. Medicare beneficiaries can realize significant out-of-pocket cost savings for their drugs by taking CMS-suggested generic treatment alternatives. However, due to larger discounts on brand medications made available through recent changes reducing the coverage gap, the potential dollar savings by taking suggested generic treatment alternatives during the gap is less compelling and will decrease as subsidies increase.
Cha, Seungman; Mankadi, Paul Mansiangi; Elhag, Mousab Siddig; Lee, Yongjoo; Jin, Yan
2017-01-01
ABSTRACT Background: As the Millennium Development Goals ended, and were replaced by the Sustainable Development Goals, efforts have been made to evaluate the achievements and performance of official development assistance (ODA) in the health sector. In this study, we explore trends in the expansion of water and sanitation coverage in developing countries and the performance of ODA. Design: We explored inequality across developing countries by income level, and investigated how ODA for water and sanitation was committed by country, region, and income level. Changes in inequality were tested via slope changes by investigating the interaction of year and income level with a likelihood ratio test. A random effects model was applied according to the results of the Hausman test. Results: The slope of the linear trend between economic level and sanitation coverage has declined over time. However, a random effects model suggested that the change in slope across years was not significant (e.g. for the slope change between 2000 and 2010: likelihood ratio χ2 = 2.49, probability > χ2 = 0.1146). A similar pro-rich pattern across developing countries and a non-significant change in the slope associated with different economic levels were demonstrated for water coverage. Our analysis shows that the inequality of water and sanitation coverage among countries across the world has not been addressed effectively during the past decade. Our findings demonstrate that the countries with the least coverage persistently received far less ODA per capita than did countries with much more extensive water and sanitation coverage, suggesting that ODA for water and sanitation is poorly targeted. Conclusion: The most deprived countries should receive more attention for water and sanitation improvements from the world health community. A strong political commitment to ODA targeting the countries with the least coverage is needed at the global level. PMID:28604256
SU-E-T-333: Dosimetric Impact of Rotational Error On the Target Coverage in IMPT Lung Cancer Plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rana, S; Zheng, Y
2015-06-15
Purpose: The main purpose of this study was to investigate the impact of rotational (yaw, roll, and pitch) error on the planning target volume (PTV) coverage in lung cancer plans generated by intensity modulated proton therapy (IMPT). Methods: In this retrospective study, computed tomography (CT) dataset of previously treated lung case was used. IMPT plan were generated on the original CT dataset using left-lateral (LL) and posterior-anterior (PA) beams for a total dose of 74 Gy[RBE] with 2 Gy[RBE] per fraction. In order to investigate the dosimetric impact of rotational error, 12 new CT datasets were generated by re-sampling themore » original CT dataset for rotational (roll, yaw, and pitch) angles ranged from −5° to +5°, with an increment of 2.5°. A total of 12 new IMPT plans were generated based on the re-sampled CT datasets using beam parameters identical to the ones in the original IMPT plan. All treatment plans were generated in XiO treatment planning system. The PTV coverage (i.e., dose received by 95% of the PTV volume, D95) in new IMPT plans were then compared with the PTV coverage in the original IMPT plan. Results: Rotational errors caused the reduction in the PTV coverage in all 12 new IMPT plans when compared to the original IMPT lung plan. Specifically, the PTV coverage was reduced by 4.94% to 50.51% for yaw, by 4.04% to 23.74% for roll, and by 5.21% to 46.88% for pitch errors. Conclusion: Unacceptable dosimetric results were observed in new IMPT plans as the PTV coverage was reduced by up to 26.87% and 50.51% for rotational error of 2.5° and 5°, respectively. Further investigation is underway in evaluating the PTV coverage loss in the IMPT lung cancer plans for smaller rotational angle change.« less
2013-07-15
This final rule implements provisions of the Patient Protection and Affordable Care Act and the Health Care and Education Reconciliation Act of 2010 (collectively referred to as the Affordable Care Act. This final rule finalizes new Medicaid eligibility provisions; finalizes changes related to electronic Medicaid and the Children's Health Insurance Program (CHIP) eligibility notices and delegation of appeals; modernizes and streamlines existing Medicaid eligibility rules; revises CHIP rules relating to the substitution of coverage to improve the coordination of CHIP coverage with other coverage; and amends requirements for benchmark and benchmark-equivalent benefit packages consistent with sections 1937 of the Social Security Act (which we refer to as ``alternative benefit plans'') to ensure that these benefit packages include essential health benefits and meet certain other minimum standards. This rule also implements specific provisions including those related to authorized representatives, notices, and verification of eligibility for qualifying coverage in an eligible employer-sponsored plan for Affordable Insurance Exchanges. This rule also updates and simplifies the complex Medicaid premium and cost sharing requirements, to promote the most effective use of services, and to assist states in identifying cost sharing flexibilities. It includes transition policies for 2014 as applicable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, M; Pompos, A; Gu, X
Purpose: To characterize the dose distributions of Cyberknife and intensity-modulated-proton-therapy (IMPT). Methods: A total of 20 patients previously treated with Cyberknife were selected. The original planning-target-volume (PTV) was used in the ‘IMPT-ideal’ plan assuming a comparable image-guidance with Cyberknife. A 3mm expansion was made to create the proton-PTV for the ‘IMPT-3mm’ plan representing the current proton-therapy where a margin of 3mm is used to account for the inferior image-guidance. The proton range uncertainty was taken-care in beam-design by adding the proximal- and distal-margins (3%water-equivalent-depth+1mm) for both proton plans. The IMPT plans were generated to meet the same target coverage asmore » the Cyberknife-plans. The plan quality of IMPT-ideal and IMPT-3mm were compared to the Cyberknife-plan. To characterize plan quality, we defined the ratio(R) of volumes encompassed by the selected isodose surfaces for Cyberknife and IMPT plans (VCK/VIMPT). Comparisons were made for both Cyberknife versus IMPT-ideal and Cyberknife versusIMPT-3mm to further discuss the impact of setup error margins used in proton therapy and the correlation with target size and location. Results: IMPT-ideal plans yield comparable plan quality as CK plans and slightly better OAR sparing while the IMPT-3mm plan results in a higher dose to the OARs, especially for centralized tumors. Comparing to the IMPT-ideal plans, a slightly larger 80% (Ravg=1.05) dose cloud and significantly larger 50% (Ravg=1.3) and 20% (Ravg=1.60) dose clouds are seen in CK plans. However, the 3mm expansion results in a larger high and medium dose clouds in IMPT-3mm plans (Ravg=0.65 for 80%-isodose; Ravg=0.93 for 50%-isodose). The trend increases with the size of the target and the distance from the brainstem to the center of target. Conclusion: Cyberknife is more preferable for treating centralized targets and proton therapy is advantageous for the large and peripheral targets. Advanced image guidance would improve the efficacy of proton therapy for intracranial treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, T; Wang, L; Galloway, T
Purpose: Head and Neck cancer treatment with IMRT/VMAT has two choices: split-filed IMRT(SFI), in which the LAN is treated with a separate anterior field and the extended whole-field IMRT(WFI) in which LAN is included with the IMRT/VMAT field. This study shows that under the same dose limit criteria, choosing the technique becomes a critical issue if daily localization and immobilization altered the dose distribution. Methods: Nine common head-and-neck cancer cases were chosen to illustrate how the daily localization and immobilization uncertainties affect to choose between SFI and WFI. Both SFI and WFI at upper target coverage were generated with VMAT.more » For each case, the same planning criteria were applied to the target and critical structures; therefore, similar target coverage and dose falloff can be observed in both techniques. Thirty days of kV cone beam CT(CBCT) images on each case were also delineated with contralateral and ipsilateral target as well as larynx as critical structure. About 300 CBCT images with daily delivered doses were analyzed and compared in a form of dose-volume histograms. Results: While both plans for SFI and WFI with VMAT planning utilized and meet the criteria of D95>prescription dose and for not-involved larynx with mean dose <35Gy and V55<10%, the daily localization and immobilization has a great contribution to the resulted dose delivery. With WFI, the better daily contralateral and ipsilateral neck target coverage can reflect a simpler or shorter localization; however, a much superior avoidance (WFI: mean dose a 42.5Gy; SFI: mean dose a 18.9Gy) of the non-involved larynx from the SFI is preferred. Conclusion: Dosimetrically, SFI and WFI are equally well for head and Neck cancer treatment with VMAT technique; however, if considering the contribution of daily localization(CBCT) method uncertainties, SFI is better with sparing non-involved larynx and WFI has better target coverage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sivakumar, R; Janardhan, N; Bhavani, P
Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 inmore » 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered shorter delivery time than 7F-IMRT and 9F-IMRT without compromising the plan quality.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, C; Giaddui, T; Den, R
2014-06-15
Purpose: To investigate the adherence of treatment plans of prostate cancer patients with the dosimetric compliance criteria of the new in house phase I trial of high dose rate (HDR) brachytherapy combined with stereotactic body radiotherapy (SBRT) for intermediate risk prostate cancer patients. Methods: Ten prostate cancer patients were treated using this trial. They received one fraction of HDR to 15Gy, followed by external beam(EB) boost of 3.2Gy(Level 1, five patients) or 3.94Gy(level 2, five patients) per fraction for 10 or 7 fractions, respectively, both equivalent to EB treatments of 113.5Gy in 2Gy fractions. The EB plans were either IMRTmore » or VMAT plans. DVH analysis was performed to verify the adherence of treatment plans to the dosimetric criteria of the trial. Results: For Level 1 patients, target coverage were adequate, with CTV V32Gy(%) of 99.0±1.0 (mean ± 1 standard deviation), and PTV V31Gy(%) of 99.6±0.3. PTV V32.9Gy(%) is 1.4±3.1 and PTVmax is 32.9±0.2Gy. Rectum, bladder and femoral heads sparing were well within protocol criteria. For Level 2 patients, CTV V27.6Gy(%) is 98.7±1.8; PTV V26.7Gy(%) is 99.0±1.4. PTV V28.4Gy(%) is 1.3±1.4, with three patients having minor deviation from protocol. Again critical structures were spared compliant to the protocol. The analysis of HDR plans show similar results, with adequate dose coverage to the prostate and sparing of critical structures including urethra and rectum. V100(%) and V90(%) of prostate are 96.0±1.1 and 98.9±0.5. Urethra D10(%) is 113.1±2.9. Rectum V80(cc) is 1.4±0.5. Hotspot in prostate is substantially higher than what the protocol specifies. But the criteria for hotspot are only guidelines, serving to lower the dose to urethra . Conclusion: This new high biological equivalent dose prostate trial has been carried out successfully for ten patients. Based on dosimetric analysis, all HDR and external plans were compliant to the protocol criteria, with only minor deviations.« less
Wehby, George L; Lyu, Wei
2018-04-01
Examine the ACA Medicaid expansion effects on Medicaid take-up and private coverage through 2015 and coverage disparities by age, race/ethnicity, and gender. 2011-2015 American Community Survey for 3,137,989 low-educated adults aged 19-64 years. Difference-in-differences regressions accounting for national coverage trends and state fixed effects. Expansion effects doubled in 2015 among low-educated adults, with a nearly 8 percentage-point increase in Medicaid take-up and 6 percentage-point decline in uninsured rate. Significant coverage gains were observed across virtually all examined groups by age, gender, and race/ethnicity. Take-up and insurance declines were strongest among younger adults and were generally close by gender and race/ethnicity. Despite the increased take-up however, coverage disparities remained sizeable, especially for young adults and Hispanics who had declining but still high uninsured rates in 2015. There was some evidence of private coverage crowd-out in certain subgroups, particularly among young adults aged 19-26 years and women, including in both individually purchased and employer-sponsored coverage. The ACA Medicaid expansions have continued to increase coverage in 2015 across the entire population of low-educated adults and have reduced age disparities in coverage. However, there is still a need for interventions that target eligible young and Hispanic adults. © Health Research and Educational Trust.
Fogliata, Antonella; Scorsetti, Marta; Navarria, Piera; Catalano, Maddalena; Clivio, Alessandro; Cozzi, Luca; Lobefalo, Francesca; Nicolini, Giorgia; Palumbo, Valentina; Pellegrini, Chiara; Reggiori, Giacomo; Roggio, Antonella; Vanetti, Eugenio; Alongi, Filippo; Pentimalli, Sara; Mancosu, Pietro
2013-04-01
To appraise the potential of volumetric modulated arc therapy (VMAT, RapidArc) and proton beams to simultaneously achieve target coverage and enhanced sparing of bone tissue in the treatment of soft-tissue sarcoma with adequate target coverage. Ten patients presenting with soft-tissue sarcoma of the leg were collected for the study. Dose was prescribed to 66.5 Gy in 25 fractions to the planning target volume (PTV) while significant maximum dose to the bone was constrained to 50 Gy. Plans were optimised according to the RapidArc technique with 6 MV photon beams or for intensity modulated protons. RapidArc photon plans were computed with: 1) AAA; 2) Acuros XB as dose to medium; and 3) Acuros XB as dose to water. All plans acceptably met the criteria of target coverage (V95% >90-95%) and bone sparing (D(1 cm3) <50 Gy). Significantly higher PTV dose homogeneity was found for proton plans. Near-to-maximum dose to bone was similar for RapidArc and protons, while volume receiving medium/low dose levels was minimised with protons. Similar results were obtained for the remaining normal tissue. Dose distributions calculated with the dose to water option resulted ~5% higher than corresponding ones computed as dose to medium. High plan quality was demonstrated for both VMAT and proton techniques when applied to soft-tissue sarcoma.
Leto Barone, Angelo A; Mastroianni, Melissa; Farkash, Evan A; Mallard, Christopher; Albritton, Alexander; Torabi, Radbeh; Leonard, David A; Kurtz, Josef M; Sachs, David H; Cetrulo, Curtis L
2015-05-01
Temporary coverage of severely burned patients with cadaver allograft skin represents an important component of burn care, but is limited by availability and cost. Porcine skin shares many physical properties with human skin, but is susceptible to hyperacute rejection due to preformed antibodies to α-1,3-galactose (Gal), a carbohydrate on all porcine cells. Our preliminary studies have suggested that skin grafts from α-1,3-galactosyltransferase knock out (GalT-KO) miniature swine might provide temporary wound coverage comparable to allografts, since GalT-KO swine lack this carbohydrate. To further evaluate this possibility, eight non-human primates received primary autologous, allogeneic, GalT-KO, and GalT+xenogeneic skin grafts. Additionally, secondary grafts were placed to assess whether sensitization would affect the rejection time course of identical-type grafts. We demonstrate that both GalT-KO xenografts and allografts provide temporary coverage of partial- and full-thickness wounds for up to 11 days. In contrast, GalT+xenografts displayed hyperacute rejection, with no signs of vascularization and rapid avulsion from wounds. Furthermore, secondary GalT-KO transplants failed to vascularize, demonstrating that primary graft rejection sensitizes the recipient. We conclude that GalT-KO xenografts may provide temporary coverage of wounds for a duration equivalent to allografts, and thus, could serve as a readily available alternative treatment of severe burns. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Felipe, Maria Emília M C; Andrade, Patrícia F; Grisi, Marcio F M; Souza, Sérgio L S; Taba, Mário; Palioto, Daniela B; Novaes, Arthur B
2007-07-01
The aim of this randomized, controlled, clinical investigation was to compare two surgical techniques for root coverage with the acellular dermal matrix graft to evaluate which technique provided better root coverage, a better esthetic result, and less postoperative discomfort. Fifteen patients with bilateral Miller Class I or II gingival recessions were selected. Fifteen pairs of recessions were treated and assigned randomly to the test group, and the contralateral recessions were assigned to the control group. The control group was treated with a broader flap and vertical releasing incisions; the test group was treated with the proposed surgical technique, without vertical releasing incisions. The clinical parameters evaluated were probing depth, relative clinical attachment level, gingival recession (GR), width of keratinized tissue, thickness of keratinized tissue, esthetic result, and pain evaluation. The measurements were taken before the surgeries and after 6 months. At baseline, all parameters were similar for both groups. At 6 months, a statistically significant greater reduction in GR favored the control group. The percentage of root coverage was 68.98% and 84.81% for the test and control groups, respectively. The esthetic result was equivalent between the groups, and all patients tolerated both procedures well. Both techniques provided significant root coverage, good esthetic results, and similar levels of postoperative discomfort. However, the control technique had statistically significantly better results for root coverage of localized gingival recessions.
Johansson, Kjell Arne; Strand, Kirsten Bjerkreim; Fekadu, Abebaw; Chisholm, Dan
2017-04-01
Mental and neurological (MN) health care has long been neglected in low-income settings. This paper estimates health and non-health impacts of fully publicly financed care for selected key interventions in the National Mental Health Strategy in Ethiopia for depression, bipolar disorder, schizophrenia and epilepsy. A methodology of extended cost-effectiveness analysis (ECEA) is applied to MN health care in Ethiopia. The impact of providing a package of selected MN interventions free of charge in Ethiopia is estimated for: epilepsy (75% coverage, phenobarbital), depression (30% coverage, fluoxetine, cognitive therapy and proactive case management), bipolar affective disorder (50% coverage, valproate and psychosocial therapy) and schizophrenia (75% coverage, haloperidol plus psychosocial treatment). Multiple outcomes are estimated and disaggregated across wealth quintiles: (1) healthy-life-years (HALYs) gained; (2) household out-of-pocket (OOP) expenditures averted; (3) expected financial risk protection (FRP); and (4) productivity impact. The MN package is expected to cost US$177 million and gain 155,000 HALYs (epilepsy US$37m and 64,500 HALYs; depression US$65m and 61,300 HALYs; bipolar disorder US$44m and 20,300 HALYs; and schizophrenia US$31m and 8,900 HALYs) annually. The health benefits would be concentrated among the poorest groups for all interventions. Universal public finance averts little household OOP expenditures and provides minimal FRP because of the low current utilization of these MN services in Ethiopia. In addition, economic benefits of US$ 51 million annually are expected from depression treatment in Ethiopia as a result of productivity gains, equivalent to 78% of the investment cost. The total MN package in Ethiopia is estimated to cost equivalent to US$1.8 per capita and yields large progressive health benefits. The expected productivity gain is substantially higher than the expected FRP. The ECEA approach seems to fit well with the current policy challenges and captures important equity concerns of scaling up MN programmes. © The Author 2016. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
EPA Region 1 Environmentally Sensitive Areas
This coverage represents polygon equivalents of environmentally sensitive areas (ESA) in EPA Region I. ESAs were developed as part of an EPA headquarters initiative based on reviews of various regulatory and guidance documents, as well as phone interviews with federal/state/local government agencies and private organizations. ESAs include, but are not limited to, wetlands, biological resources, habitats, national parks, archaeological/historic sites, natural heritage areas, tribal lands, drinking water intakes, marinas/boat ramps, wildlife areas, etc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Souris, K; University of Pennsylvania, Philadelphia, PA; Glick, A
Purpose: To study if abdominal compression can reduce breathing motion and mitigate interplay effect in pencil beam scanning proton therapy (PBSPT) treatment of liver tumors in order to better spare healthy liver volumes compared with photon therapy. Methods: Ten patients, six having large tumors initially treated with IMRT and four having small tumors treated with SBRT, were replanned for PBSPT. ITV and beam-specific PTVs based on 4D-CT were used to ensure target coverage in PBSPT. The use of an abdominal compression belt and volumetric repainting was investigated to mitigate the interplay effect between breathing motion and PBSPT dynamic delivery. Anmore » in-house Matlab script has been developed to simulate this interplay effect. The dose is computed on each phase individually by sorting all spots according to their simulated delivery timing. The final dose distribution is then obtained by accumulating all dose maps to a reference phase. Results: For equivalent target coverage PBSPT reduced average healthy liver dose by 9.5% of the prescription dose compared with IMRT/SBRT. Abdominal compression of 113.2±42.2 mmHg was effective for all 10 patients and reduced average motion by 2.25 mm. As a result, the average ITV volume decreased from 128.2% to 123.1% of CTV volume. Similarly, the average beam-specific PTV volume decreased from 193.2% to 183.3%. For 8 of the 10 patients, the average motion was reduced below 5 mm, and up to 3 repainting were sufficient to mitigate interplay. For the other two patients with larger residual motion, 4–5 repainting were needed. Conclusion: We recommend evaluation of the 4DCT motion histogram following simulation and the interplay effect following treatment planning in order to personalize the use of compression and volumetric repainting for each patient. Abdominal compression enables safe and more effective PBS treatment of liver tumors by reduction of motion and interplay effect. Kevin Souris is supported by IBA and Televie Grant from F.R.S.-FNRS. Liyong Lin is partially supported by Varian.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nie, K; Yue, N; Chen, T
2014-06-15
Purpose: In lung radiation treatment, PTV is formed with a margin around GTV (or CTV/ITV). Although GTV is most likely of water equivalent density, the PTV margin may be formed with the surrounding low-density tissues, which may lead to unreal dosimetric plan. This study is to evaluate whether the concern of dose calculation inside the PTV with only low density margin could be justified in lung treatment. Methods: Three SBRT cases were analyzed. The PTV from the original plan (Plan-O) was created with a 5–10 mm margin outside the ITV to incorporate setup errors and all mobility from 10 respiratorymore » phases. Test plans were generated with the GTV shifted to the PTV edge to simulate the extreme situations with maximum setup uncertainties. Two representative positions as the very posterior-superior (Plan-PS) and anterior-inferior (Plan-AI) edge were considered. The virtual GTV was assigned a density of 1.0 g.cm−3 and surrounding lung, including the PTV margin, was defined as 0.25 g.cm−3. Also, additional plan with a 1mm tissue-margin instead of full lung-margin was created to evaluate whether a composite-margin (Plan-Comp) has a better approximation for dose calculation. All plans were generated on the average CT using Analytical Anisotropic Algorithm with heterogeneity correction on and all planning parameters/monitor unites remained unchanged. DVH analyses were performed for comparisons. Results: Despite the non-static dose distribution, the high-dose region synchronized with tumor positions. This might due to scatter conditions as greater doses were absorbed in the solid-tumor than in the surrounding low-density lungtissue. However, it still showed missing target coverage in general. Certain level of composite-margin might give better approximation for the dosecalculation. Conclusion: Our exploratory results suggest that with the lungmargin only, the planning dose of PTV might overestimate the coverage of the target during treatment. The significance of this overestimation might warrant further investigation.« less
Vogel, J; Lin, L; Litzky, L A; Berman, A T; Simone, C B
2017-10-01
Thymic malignancies are the most common tumors of the anterior mediastinum. The benefit of adjuvant radiation therapy for stage II disease remains controversial, and patients treated with adjuvant radiation therapy are at risk of late complications, including radiation-induced secondary malignant neoplasms (SMNs), that may reduce the overall benefit of treatment. We assess the risk of predicted SMNs following adjuvant proton radiation therapy compared with photon radiation therapy after resection of stage II thymic malignancies to determine whether proton therapy improves the risk-benefit ratio. Ten consecutive patients treated with double-scattered proton beam radiation therapy (DS-PBT) were prospectively enrolled in an institutional review board-approved proton registry study. All patients were treated with DS-PBT. Intensity modulated radiation therapy (IMRT) plans for comparison were generated. SMN risk was calculated based on organ equivalent dose. Patients had a median age of 65 years (range, 25-77 years), and 60% were men. All patients had stage II disease, and many had close or positive margins (60%). The median dose was 50.4 Gy (range, 50.4-54.0 Gy) in 1.8-Gy relative biological effectiveness daily fractions. No differences in target coverage were seen with DS-PBT compared with IMRT plans. Significant reductions were seen in mean and volumetric lung, heart, and esophageal doses with DS-PBT compared with IMRT plans (all P≤.01). Significant reductions in SMNs in the lung, breast, esophagus, skin, and stomach were seen with DS-PBT compared with IMRT. For patients with thymoma diagnosed at the median national age, 5 excess secondary malignancies per 100 patients would be avoided by treating them with protons instead of photons. Treatment with proton therapy can achieve comparable target coverage but significantly reduced doses to critical normal structures, which can lead to fewer predicted SMNs compared with IMRT. By decreasing expected late complications, proton therapy may improve the therapeutic ratio of adjuvant radiation therapy for patients with stage II thymic malignancies. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Yang; Song, Hai-Ying; Liu, H. Y.; Liu, Shi-Bing
2017-07-01
We theoretically study high-order harmonic generation (HHG) from relativistically driven overdense plasma targets with rectangularly grating-structured surfaces by femtosecond laser pulses. Our particle-in-cell (PIC) simulations show that, under the conditions of low laser intensity and plasma density, the harmonics emit principally along small angles deviating from the target surface. Further investigation of the surface electron dynamics reveals that the electron bunches are formed by the interaction between the laser field and the target surface, giving rise to the oscillation of equivalent electric-dipole (OEED), which enhances specific harmonic orders. Our work helps understand the mechanism of harmonic emissions from grating targets and the distinction from the planar harmonic scheme.
Evidence-based alternatives for autogenous grafts around teeth: outcomes, attachment, and stability.
McGuire, Michael K
2014-06-01
Although the use of autogenous harvested tissues has proven to be the gold standard for soft tissue augmentation procedures involving root coverage or generation of keratinized tissue, harvest site morbidity and limited supply have prompted clinicians to seek graft alternatives. Using a hierarchy of evidence, the author reviews both clinical and patient-reported results for harvest graft substitutes and, considering his own research experience, reviews autogenous graft substitute outcomes, attachment, and stability over time. Overall, when the goal is keratinized-tissue generation, living cellular constructs and xenogeneic collagen matrices have provided acceptable clinical results, but with better esthetics and patient preference than autogenous free gingival grafts. For root coverage therapy, enamel matrix derivatives, platelet-derived growth factors, and xenogeneic collagen matrices have provided acceptable results with equivalent esthetics to autogenous connective tissue grafts, while also being preferred by patients. Longterm results for enamel matrix derivatives, platelet-derived growth factors, and xenogeneic collagen matrices indicate root coverage can be maintained over time. In the author's hands, xenogeneic collagen matrices have been the only harvest graft alternatives that can be used either covered or uncovered by soft tissue.
Part D employer retiree drug subsidy: inception, implementation and issues.
Costello, Ann
2010-01-01
The Medicare Prescription Drug, Improvement, and Modernization Act of 2003 provided a subsidy to employers that offered a retiree health prescription coverage benefit actuarially equivalent to Medicare Part D. This article reviews the development of the subsidy, the support by the federal government and the issues that have arisen. It also presents analysis of data from a set of companies that offered retiree health in 2006 and 2007. The data show widespread acceptance of the subsidy and continuance of prescription coverage; however, companies that did not take the subsidy were more likely to be smaller and in less robust financial health. Analysis of a subset of the companies shows the magnitude of the benefits paid yearly and the accounting liability caused by retiree health relative to the size of the subsidy. The author concludes that the potential success or failure of the federal subsidy in preserving retiree health benefits will not be known for years. Nevertheless, with the elimination of the deductibility of the subsidy in the Patient Protection and Affordable Care Act (PPACA), employers surely will reexamine their offer of prescription coverage to retirees.
NASA Astrophysics Data System (ADS)
Hellberg, Lars; Kasemo, Bengt
Some strongly exothermic and non-adiabatic surface adsorption events, especially those where electronegative molecules adsorb on very electropositive (low work function) surfaces, are accompanied by emission of (exo)electrons, photons, excited atoms and negative ions. The reaction of halogen molecules with halogen surfaces constitute an efficient model system for such studies. We have previously reported data for the emission of negative particles and photons in the zero coverage limit for a range of velocities of Cl2 molecules impinging on cold potassium surfaces as well as the mechanism behind these emission processes. In the present work, we focus on measurements of the kinetics, i.e. the exposure/coverage dependence, of these processes for the same system. Specifically, we present data for, (i) the separated contributions from electrons and Cl- ions of the emitted negative particles, (ii) the photon emission stemming both from excited Potassium atoms and from the equivalent process causing electron emission, (iii) the change of the work function during the initial exposure and, finally, (iv) the sticking coefficient for different Cl2 velocities and exposures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dellamonica, D.; Luo, G.; Ding, G.
Purpose: Setup errors on the order of millimeters may cause under-dosing of targets and significant changes in dose to critical structures especially when planning with tight margins in stereotactic radiosurgery. This study evaluates the effects of these types of patient positioning uncertainties on planning target volume (PTV) coverage and cochlear dose for stereotactic treatments of acoustic neuromas. Methods: Twelve acoustic neuroma patient treatment plans were retrospectively evaluated in Brainlab iPlan RT Dose 4.1.3. All treatment beams were shaped by HDMLC from a Varian TX machine. Seven patients had planning margins of 2mm, five had 1–1.5mm. Six treatment plans were createdmore » for each patient simulating a 1mm setup error in six possible directions: anterior-posterior, lateral, and superiorinferior. The arcs and HDMLC shapes were kept the same for each plan. Change in PTV coverage and mean dose to the cochlea was evaluated for each plan. Results: The average change in PTV coverage for the 72 simulated plans was −1.7% (range: −5 to +1.1%). The largest average change in coverage was observed for shifts in the patient's superior direction (−2.9%). The change in mean cochlear dose was highly dependent upon the direction of the shift. Shifts in the anterior and superior direction resulted in an average increase in dose of 13.5 and 3.8%, respectively, while shifts in the posterior and inferior direction resulted in an average decrease in dose of 17.9 and 10.2%. The average change in dose to the cochlea was 13.9% (range: 1.4 to 48.6%). No difference was observed based on the size of the planning margin. Conclusion: This study indicates that if the positioning uncertainty is kept within 1mm the setup errors may not result in significant under-dosing of the acoustic neuroma target volumes. However, the change in mean cochlear dose is highly dependent upon the direction of the shift.« less
Nájera-Aguilar, P; Infante-Castañeda, C
1990-01-01
Less than a third of the non-insured population studied through a sample in the State of Mexico was covered by the Institute of Health of the State of México. This low coverage was observed in spite the fact that health services were available within 2 kilometer radius. 33 per cent of the non-insured preferred to utilize other services within their own community, and 24 per cent of them traveled to bigger localities to receive care. These results suggest that to attain adequate coverage, utilization patterns should be investigated so that health services can meet the needs of the target population.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geng, C; Nanjing University of Aeronautics and Astronautics, Nanjing; Schuemann, J
Purpose: To determine the neutron contamination from the aperture in pencil beam scanning during proton therapy. Methods: A Monte Carlo based proton therapy research platform TOPAS and the UF-series hybrid pediatric phantoms were used to perform this study. First, pencil beam scanning (PBS) treatment pediatric plans with average spot size of 10 mm at iso-center were created and optimized for three patients with and without apertures. Then, the plans were imported into TOPAS. A scripting method was developed to automatically replace the patient CT with a whole body phantom positioned according to the original plan iso-center. The neutron dose equivalentmore » was calculated using organ specific quality factors for two phantoms resembling a 4- and 14-years old patient. Results: The neutron dose equivalent generated by the apertures in PBS is 4–10% of the total neutron dose equivalent for organs near the target, while roughly 40% for organs far from the target. Compared to the neutron dose equivalent caused by PBS without aperture, the results show that the neutron dose equivalent with aperture is reduced in the organs near the target, and moderately increased for those organs located further from the target. This is due to the reduction of the proton dose around the edge of the CTV, which causes fewer neutrons generated in the patient. Conclusion: Clinically, for pediatric patients, one might consider adding an aperture to get a more conformal treatment plan if the spot size is too large. This work shows the somewhat surprising fact that adding an aperture for beam scanning for facilities with large spot sizes reduces instead of increases a potential neutron background in regions near target. Changran Geng is supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087)« less
A catalog of putative adverse outcome pathways (AOPs) that ...
A number of putative AOPs for several distinct MIEs of thyroid disruption have been formulated for amphibian metamorphosis and fish swim bladder inflation. These have been entered into the AOP knowledgebase on the OECD WIKI. The EDSP has been actively advancing high-throughput screening for chemical activity toward estrogen, androgen and thyroid targets. However, it has been recently identified that coverage for thyroid-related targets is lagging behind estrogen and androgen assay coverage. As thyroid-related medium-high throughput assays are actively being developed for inclusion in the ToxCast chemical screening program, a parallel effort is underway to characterize putative adverse outcome pathways (AOPs) specific to these thyroid-related targets. This effort is intended to provide biological and ecological context that will enhance the utility of ToxCast high throughput screening data for hazard identification.
Masanja, Honorati; Schellenberg, Joanna Armstrong; Mshinda, Hassan M; Shekar, Meera; Mugyabuso, Joseph K L; Ndossi, Godwin D; de Savigny, Don
2006-11-01
Efficient delivery strategies for health interventions are essential for high and sustainable coverage. We report impact of a change in programmatic delivery strategy from routine delivery through the Expanded Programme on Immunization (EPI+) approach to twice-yearly mass distribution campaigns on coverage of vitamin A supplementation in Tanzania We investigated disparities in age, sex, socio-economic status, nutritional status and maternal education within vitamin A coverage in children between 1 and 2 years of age from two independent household level child health surveys conducted (1) during a continuous universal targeting scheme based on routine EPI contacts for children aged 9, 15 and 21 months (1999); and (2) three years later after the introduction of twice-yearly vitamin A supplementation campaigns for children aged 6 months to 5 years, a 6-monthly universal targeting scheme (2002). A representative cluster sample of approximately 2,400 rural households was obtained from Rufiji, Morogoro Rural, Kilombero and Ulanga districts. A modular questionnaire about the health of all children under the age of five was administered to consenting heads of households and caretakers of children. Information on the use of child health interventions including vitamin A was asked. Coverage of vitamin A supplementation among 1-2 year old children increased from 13% [95% CI 10-18%] in 1999 to 76% [95%CI 72-81%] in 2002. In 2002 knowledge of two or more child health danger signs was negatively associated with vitamin A supplementation coverage (80% versus 70%) (p = 0.04). Nevertheless, we did not find any disparities in coverage of vitamin A by district, gender, socio-economic status and DPT vaccinations. Change in programmatic delivery of vitamin A supplementation was associated with a major improvement in coverage in Tanzania that was been sustained by repeated campaigns for at least three years. There is a need to monitor the effect of such campaigns on the routine health system and on equity of coverage. Documentation of vitamin A supplementation campaign contacts on routine maternal and child health cards would be a simple step to facilitate this monitoring.
Generation of Parametric Equivalent-Area Targets for Design of Low-Boom Supersonic Concepts
NASA Technical Reports Server (NTRS)
Li, Wu; Shields, Elwood
2011-01-01
A tool with an Excel visual interface is developed to generate equivalent-area (A(sub e)) targets that satisfy the volume constraints for a low-boom supersonic configuration. The new parametric Ae target explorer allows users to interactively study the tradeoffs between the aircraft volume constraints and the low-boom characteristics (e.g., loudness) of the ground signature. Moreover, numerical optimization can be used to generate the optimal A(sub e) target for given A(sub e) volume constraints. A case study is used to demonstrate how a generated low-boom Ae target can be matched by a supersonic configuration that includes a fuselage, wing, nacelle, pylon, aft pod, horizontal tail, and vertical tail. The low-boom configuration is verified by sonic-boom analysis with an off-body pressure distribution at three body lengths below the configuration
Decomposition of the Multistatic Response Matrix and Target Characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chambers, D H
2008-02-14
Decomposition of the time-reversal operator for an array, or equivalently the singular value decomposition of the multistatic response matrix, has been used to improve imaging and localization of targets in complicated media. Typically, each singular value is associated with one scatterer even though it has been shown in several cases that a single scatterer can generate several singular values. In this paper we review the analysis of the time-reversal operator (TRO), or equivalently the multistatic response matrix (MRM), of an array system and a small target. We begin with two-dimensional scattering from a small cylinder then show the results formore » a small non-spherical target in three dimensions. We show that the number and magnitudes of the singular values contain information about target composition, shape, and orientation.« less
Cris-atms Retrievals Using an AIRS Science Team Version 6-like Retrieval Algorithm
NASA Technical Reports Server (NTRS)
Susskind, Joel; Kouvaris, Louis C.; Iredell, Lena
2014-01-01
CrIS is the infrared high spectral resolution atmospheric sounder launched on Suomi-NPP in 2011. CrISATMS comprise the IRMW Sounding Suite on Suomi-NPP. CrIS is functionally equivalent to AIRS, the high spectral resolution IR sounder launched on EOS Aqua in 2002 and ATMS is functionally equivalent to AMSU on EOS Aqua. CrIS is an interferometer and AIRS is a grating spectrometer. Spectral coverage, spectral resolution, and channel noise of CrIS is similar to AIRS. CrIS spectral sampling is roughly twice as coarse as AIRSAIRS has 2378 channels between 650 cm-1 and 2665 cm-1. CrIS has 1305 channels between 650 cm-1 and 2550 cm-1. Spatial resolution of CrIS is comparable to AIRS.
Snow water equivalent determination by microwave radiometry
NASA Technical Reports Server (NTRS)
Chang, A. T. C.; Foster, J. L.; Hall, D. K.; Rango, A.; Hartline, B. K.
1981-01-01
One of the most important parameters for accurate snowmelt runoff prediction is snow water equivalent (SWE) which is contentionally monitored using observations made at widely scattered points in or around specific watersheds. Remote sensors which provide data with better spatial and temporal coverage can be used to improve the SWE estimates. Microwave radiation, which can penetrate through a snowpack, may be used to infer the SWE. Calculations made from a microscopic scattering model were used to simulate the effect of varying SWE on the microwave brightness temperature. Data obtained from truck mounted, airborne and spaceborne systems from various test sites were studied. The simulated SWE compares favorable with the measured SWE. In addition, whether the underlying soil is frozen or thawed can be discriminated successfully on the basis of the polarization of the microwave radiation.
Effectiveness of interventions that apply new media to improve vaccine uptake and vaccine coverage.
Odone, Anna; Ferrari, Antonio; Spagnoli, Francesca; Visciarelli, Sara; Shefer, Abigail; Pasquarella, Cesira; Signorelli, Carlo
2015-01-01
Vaccine-preventable diseases (VPD) are still a major cause of morbidity and mortality worldwide. In high and middle-income settings, immunization coverage is relatively high. However, in many countries coverage rates of routinely recommended vaccines are still below the targets established by international and national advisory committees. Progress in the field of communication technology might provide useful tools to enhance immunization strategies. To systematically collect and summarize the available evidence on the effectiveness of interventions that apply new media to promote vaccination uptake and increase vaccination coverage. We conducted a systematic literature review. Studies published from January 1999 to September 2013 were identified by searching electronic resources (Pubmed, Embase), manual searches of references and expert consultation. Study setting We focused on interventions that targeted recommended vaccinations for children, adolescents and adults and: (1) aimed at increasing community demand for immunizations, or (2) were provider-based interventions. We limited the study setting to countries that are members of the Organisation for Economic Co-operation and Development (OECD). The primary outcome was a measure of vaccination (vaccine uptake or vaccine coverage). Considered secondary outcomes included willingness to receive immunization, attitudes and perceptions toward vaccination, and perceived helpfulness of the intervention. Nineteen studies were included in the systematic review. The majority of the studies were conducted in the US (74%, n = 14); 68% (n = 13) of the studies were experimental, the rest having an observational study design. Eleven (58%) reported results on the primary outcome. Retrieved studies explored the role of: text messaging (n.7, 37%), smartphone applications (n.1, 5%), Youtube videos (n.1, 5%), Facebook (n.1, 5%), targeted websites and portals (n.4, 21%), software for physicians and health professionals (n.4, 21%), and email communication (n.1, 5%). There is some evidence that text messaging, accessing immunization campaign websites, using patient-held web-based portals and computerized reminders increase immunization coverage rates. Insufficient evidence is available on the use of social networks, email communication and smartphone applications. Although there is great potential for improving vaccine uptake and vaccine coverage by implementing programs and interventions that apply new media, scant data are available and further rigorous research - including cost-effectiveness assessments - is needed.
Kiware, Samson S; Corliss, George; Merrill, Stephen; Lwetoijera, Dickson W; Devine, Gregor; Majambere, Silas; Killeen, Gerry F
2015-01-01
Large-cage experiments indicate pyriproxifen (PPF) can be transferred from resting sites to aquatic habitats by Anopheles arabiensis--malaria vector mosquitoes to inhibit emergence of their own offspring. PPF coverage is amplified twice: (1) partial coverage of resting sites with PPF contamination results in far higher contamination coverage of adult mosquitoes because they are mobile and use numerous resting sites per gonotrophic cycle, and (2) even greater contamination coverage of aquatic habitats results from accumulation of PPF from multiple oviposition events. Deterministic mathematical models are described that use only field-measurable input parameters and capture the biological processes that mediate PPF autodissemination. Recent successes in large cages can be rationalized, and the plausibility of success under full field conditions can be evaluated a priori. The model also defines measurable properties of PPF delivery prototypes that may be optimized under controlled experimental conditions to maximize chances of success in full field trials. The most obvious flaw in this model is the endogenous relationship that inevitably occurs between the larval habitat coverage and the measured rate of oviposition into those habitats if the target mosquito species is used to mediate PPF transfer. However, this inconsistency also illustrates the potential advantages of using a different, non-target mosquito species for contamination at selected resting sites that shares the same aquatic habitats as the primary target. For autodissemination interventions to eliminate malaria transmission or vector populations during the dry season window of opportunity will require comprehensive contamination of the most challenging subset of aquatic habitats [Formula: see text] that persist or retain PPF activity (Ux) for only one week [Formula: see text], where Ux = 7 days). To achieve >99% contamination coverage of these habitats will necessitate values for the product of the proportional coverage of the ovipositing mosquito population with PPF contamination (CM) by the ovitrap-detectable rates of oviposition by wild mosquitoes into this subset of habitats [Formula: see text], divided by the titre of contaminated mosquitoes required to render them unproductive [Formula: see text], that approximately approach unity [Formula: see text]. The simple multiplicative relationship between CM and [Formula: see text], and the simple exponential decay effect they have upon uncontaminated aquatic habitats, allows application of this model by theoreticians and field biologists alike.
Effectiveness of interventions that apply new media to improve vaccine uptake and vaccine coverage
Odone, Anna; Ferrari, Antonio; Spagnoli, Francesca; Visciarelli, Sara; Shefer, Abigail; Pasquarella, Cesira; Signorelli, Carlo
2014-01-01
Background Vaccine-preventable diseases (VPD) are still a major cause of morbidity and mortality worldwide. In high and middle-income settings, immunization coverage is relatively high. However, in many countries coverage rates of routinely recommended vaccines are still below the targets established by international and national advisory committees. Progress in the field of communication technology might provide useful tools to enhance immunization strategies. Objective To systematically collect and summarize the available evidence on the effectiveness of interventions that apply new media to promote vaccination uptake and increase vaccination coverage. Design We conducted a systematic literature review. Studies published from January 1999 to September 2013 were identified by searching electronic resources (Pubmed, Embase), manual searches of references and expert consultation. Study setting We focused on interventions that targeted recommended vaccinations for children, adolescents and adults and: (1) aimed at increasing community demand for immunizations, or (2) were provider-based interventions. We limited the study setting to countries that are members of the Organisation for Economic Co-operation and Development (OECD). Main outcome measures The primary outcome was a measure of vaccination (vaccine uptake or vaccine coverage). Considered secondary outcomes included willingness to receive immunization, attitudes and perceptions toward vaccination, and perceived helpfulness of the intervention. Results Nineteen studies were included in the systematic review. The majority of the studies were conducted in the US (74%, n = 14); 68% (n = 13) of the studies were experimental, the rest having an observational study design. Eleven (58%) reported results on the primary outcome. Retrieved studies explored the role of: text messaging (n.7, 37%), smartphone applications (n.1, 5%), Youtube videos (n.1, 5%), Facebook (n.1, 5%), targeted websites and portals (n.4, 21%), software for physicians and health professionals (n.4, 21%), and email communication (n.1, 5%). There is some evidence that text messaging, accessing immunization campaign websites, using patient-held web-based portals and computerized reminders increase immunization coverage rates. Insufficient evidence is available on the use of social networks, email communication and smartphone applications. Conclusion Although there is great potential for improving vaccine uptake and vaccine coverage by implementing programs and interventions that apply new media, scant data are available and further rigorous research - including cost-effectiveness assessments - is needed. PMID:25483518
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Jun; Department of Oncology, First Affiliated Hospital of Xinxiang Medical University, 88 Jiankang Road, Weihui, Henan, 453100; Ma, Lin
2016-07-01
To investigate the dosimetric characteristics of 4 SBRT-capable dose delivery systems, CyberKnife (CK), Helical TomoTherapy (HT), Volumetric Modulated Arc Therapy (VMAT) by Varian RapidArc (RA), and segmental step-and-shoot intensity-modulated radiation therapy (IMRT) by Elekta, on isolated thoracic spinal lesions. CK, HT, RA, and IMRT planning were performed simultaneously for 10 randomly selected patients with 6 body types and 6 body + pedicle types with isolated thoracic lesions. The prescription was set with curative intent and dose of either 33 Gy in 3 fractions (3F) or 40 Gy in 5F to cover at least 90% of the planning target volume (PTV),more » correspondingly. Different dosimetric indices, beam-on time, and monitor units (MUs) were evaluated to compare the advantages/disadvantages of each delivery modality. In ensuring the dose-volume constraints for cord and esophagus of the premise, CK, HT, and RA all achieved a sharp conformity index (CI) and a small penumbra volume compared to IMRT. RA achieved a CI comparable to those from CK, HT, and IMRT. CK had a heterogeneous dose distribution in the target as its radiosurgical nature with less dose uniformity inside the target. CK had the longest beam-on time and the largest MUs, followed by HT and RA. IMRT presented the shortest beam-on time and the least MUs delivery. For the body-type lesions, CK, HT, and RA satisfied the target coverage criterion in 6 cases, but the criterion was satisfied in only 3 (50%) cases with the IMRT technique. For the body + pedicle-type lesions, HT satisfied the criterion of the target coverage of ≥90% in 4 of the 6 cases, and reached a target coverage of 89.0% in another case. However, the criterion of the target coverage of ≥90% was reached in 2 cases by CK and RA, and only in 1 case by IMRT. For curative-intent SBRT of isolated thoracic spinal lesions, RA is the first choice for the body-type lesions owing to its delivery efficiency (time); the second choice is CK or HT; HT is the preferential choice for the body + pedicle-type lesions. This study suggests further clinical investigations with longer follow-up for these studied cases.« less
Newspaper coverage of mental illness in England 2008-2011.
Thornicroft, Amalia; Goulden, Robert; Shefer, Guy; Rhydderch, Danielle; Rose, Diana; Williams, Paul; Thornicroft, Graham; Henderson, Claire
2013-04-01
Better newspaper coverage of mental health-related issues is a target for the Time to Change (TTC) anti-stigma programme in England, whose population impact may be influenced by how far concurrent media coverage perpetuates stigma and discrimination. To compare English newspaper coverage of mental health-related topics each year of the TTC social marketing campaign (2009-2011) with baseline coverage in 2008. Content analysis was performed on articles in 27 local and national newspapers on two randomly chosen days each month. There was a significant increase in the proportion of anti-stigmatising articles between 2008 and 2011. There was no concomitant proportional decrease in stigmatising articles, and the contribution of mixed or neutral elements decreased. These findings provide promising results on improvements in press reporting of mental illness during the TTC programme in 2009-2011, and a basis for guidance to newspaper journalists and editors on reporting mental illness.
Sumida, Iori; Yamaguchi, Hajime; Das, Indra J.; Kizaki, Hisao; Aboshi, Keiko; Tsujii, Mari; Yamada, Yuji; Tamari, Kiesuke; Suzuki, Osamu; Seo, Yuji; Isohashi, Fumiaki; Yoshioka, Yasuo; Ogawa, Kazuhiko
2016-01-01
The purpose of this study was to evaluate the impact of the motion interplay effect in early-stage left-sided breast cancer intensity-modulated radiation therapy (IMRT), incorporating the radiobiological gamma index (RGI). The IMRT dosimetry for various breathing amplitudes and cycles was investigated in 10 patients. The predicted dose was calculated using the convolution of segmented measured doses. The physical gamma index (PGI) of the planning target volume (PTV) and the organs at risk (OAR) was calculated by comparing the original with the predicted dose distributions. The RGI was calculated from the PGI using the tumor control probability (TCP) and the normal tissue complication probability (NTCP). The predicted mean dose and the generalized equivalent uniform dose (gEUD) to the target with various breathing amplitudes were lower than the original dose (P < 0.01). The predicted mean dose and gEUD to the OARs with motion were higher than for the original dose to the OARs (P < 0.01). However, the predicted data did not differ significantly between the various breathing cycles for either the PTV or the OARs. The mean RGI gamma passing rate for the PTV was higher than that for the PGI (P < 0.01), and for OARs, the RGI values were higher than those for the PGI (P < 0.01). The gamma passing rates of the RGI for the target and the OARs other than the contralateral lung differed significantly from those of the PGI under organ motion. Provided an NTCP value <0.05 is considered acceptable, it may be possible, by taking breathing motion into consideration, to escalate the dose to achieve the PTV coverage without compromising the TCP. PMID:27534793
Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Singleton, James A; Kolasa, Maureen
2015-08-28
The reduction in morbidity and mortality associated with vaccine-preventable diseases in the United States has been described as one of the 10 greatest public health achievements of the first decade of the 21st century. A recent analysis concluded that routine childhood vaccination will prevent 322 million cases of disease and about 732,000 early deaths among children born during 1994-2013, for a net societal cost savings of $1.38 trillion. The National Immunization Survey (NIS) has monitored vaccination coverage among U.S. children aged 19-35 months since 1994. This report presents national, regional, state, and selected local area vaccination coverage estimates for children born from January 2011 through May 2013, based on data from the 2014 NIS. For most vaccinations, there was no significant change in coverage between 2013 and 2014. The exception was hepatitis A vaccine (HepA), for which increases were observed in coverage with both ≥1 and ≥2 doses. As in previous years, <1% of children received no vaccinations. National coverage estimates indicate that the Healthy People 2020 target* of 90% was met for ≥3 doses of poliovirus vaccine (93.3%), ≥1 dose of measles, mumps, and rubella vaccine (MMR) (91.5%), ≥3 doses of hepatitis B vaccine (HepB) (91.6%), and ≥1 dose of varicella vaccine (91.0%). Coverage was below target for ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine (DTaP), the full series of Haemophilus influenzae type b (Hib) vaccine, hepatitis B (HepB) birth dose,† ≥4 doses pneumococcal conjugate vaccine (PCV), ≥2 doses of HepA, the full series of rotavirus vaccine, and the combined vaccine series.§ Examination of coverage by child's race/ethnicity revealed lower estimated coverage among non-Hispanic black children compared with non-Hispanic white children for several vaccinations, including DTaP, the full series of Hib, PCV, rotavirus vaccine, and the combined series. Children from households classified as below the federal poverty level had lower estimated coverage for almost all of the vaccinations assessed, compared with children living at or above the poverty level. Significant variation in coverage by state¶ was observed for several vaccinations, including HepB birth dose, HepA, and rotavirus. High vaccination coverage must be maintained across geographic and sociodemographic groups if progress in reducing the impact of vaccine-preventable diseases is to be sustained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lian, J; Matney, J; Chao, E
2015-06-15
Purpose: TomoTherapy treatment has unique challenges in handling intrafractional motion compared to conventional LINAC. This study is aimed to gain a realistic and quantitative understanding of motion impact on TomoTherapy SBRT treatment of lung and prostate cancer patients. Methods: A 4D dose engine utilizing GPUs and including motion during treatment was developed for the efficient simulation of TomoTherapy delivered dosimetry. Two clinical CyberKnife lung cases with respiratory motion tracking and two prostate cases with a slower non-periodical organ motion treated by LINAC plus Calypso tracking were used in the study. For each disease site, one selected case has an averagemore » motion (6mm); the other has a large motion (10mm for lung and 15mm for prostate). SBRT of lung and prostate cases were re-planned on TomoTherapy with 12 Gyx4 fractions and 7Gyx5 fractions, respectively, all with 95% PTV coverage. Each case was planned with 4 jaw settings: 1) conventional 1cm static, 2) 2.5cm static, 3) 2.5cm dynamic, and 4) 5cm dynamic. The intrafractional rigid motion of the target was applied in the dose calculation of individual fractions of each plan and total dose was accumulated from multiple fractions. Results: For 1cm static jaw plans with motions applied, PTV coverage is related to motion type and amplitude. For SBRT patients with average motion (6mm), the PTV coverage remains > 95% for lung case and 74% for prostate case. For cases with large motion, PTV coverage drops to 61% for lung SBRT and 49% for prostate SBRT. Plans with other jaws improve uniformity of moving target, but still suffer from poor PTV coverage (< 70%). Conclusion: TomoTherapy lung SBRT is less motion-impacted when average amplitude of respiratory-induced intrafractional motion is present (6mm). When motion is large and/or non-periodic (prostate), all studied plans lead to significantly decreased target coverage in actual delivered dosimetry.« less
Arbyn, Marc; Fabri, Valérie; Temmerman, Marleen; Simoens, Cindy
2014-01-01
Objective To assess the coverage for cervical cancer screening as well as the use of cervical cytology, colposcopy and other diagnostic and therapeutic interventions on the uterine cervix in Belgium, using individual health insurance data. Methods The Intermutualistic Agency compiled a database containing 14 million records from reimbursement claims for Pap smears, colposcopies, cervical biopsies and surgery, performed between 2002 and 2006. Cervical cancer screening coverage was defined as the proportion of women aged 25–64 that had a Pap smear within the last 3 years. Results Cervical cancer screening coverage was 61% at national level, for the target population of women between 25 and 64 years old, in the period 2004–2006. Differences between the 3 regions were small, but varied more substantially between provinces. Coverage was 70% for 25–34 year old women, 67% for those aged 35–39 years, and decreased to 44% in the age group of 60–64 years. The median screening interval was 13 months. The screening coverage varied substantially by social category: 40% and 64%, in women categorised as beneficiary or not-beneficiary of increased reimbursement from social insurance, respectively. In the 3-year period 2004–2006, 3.2 million screen tests were done in the target group consisting of 2.8 million women. However, only 1.7 million women got one or more smears and 1.1 million women had no smears, corresponding to an average of 1.88 smears per woman in three years of time. Colposcopy was excessively used (number of Pap smears over colposcopies = 3.2). The proportion of women with a history of conisation or hysterectomy, before the age of 65, was 7% and 19%, respectively. Conclusion The screening coverage increased slightly from 59% in 2000 to 61% in 2006. The screening intensity remained at a high level, and the number of cytological examinations was theoretically sufficient to cover more than the whole target population. PMID:24690620
Palache, A; Abelin, A; Hollingsworth, R; Cracknell, W; Jacobs, C; Tsai, T; Barbosa, P
2017-08-24
There is no global monitoring system for influenza vaccination coverage, making it difficult to assess progress towards the 2003 World Health Assembly (WHA) vaccination coverage target. In 2008, the IFPMA Influenza Vaccine Supply International Task Force (IVS) developed a survey method to assess the global distribution of influenza vaccine doses as a proxy for vaccination coverage rates. The latest dose distribution data for 2014 and 2015 was used to update previous analyses. Data were confidentially collected and aggregated by the IFPMA Secretariat, and combined with previous IFPMA IVS survey data (2004-2013). Data were available from 201 countries over the 2004-2015 period. A "hurdle" rate was defined as the number of doses required to reach 15.9% of the population in 2008. Overall, the number of distributed doses progressively increased between 2004 and 2011, driven by a 150% increase in AMRO, then plateaued. One percent fewer doses were distributed in 2015 than in 2011. Twenty-three countries were above the hurdle rate in 2015, compared to 15 in 2004, but distribution was highly uneven in and across all WHO regions. Three WHO regions (AMRO, EURO and WPRO) accounted for about 95% of doses distributed. But in EURO and WPRO, distribution rates in 2015 were only marginally higher than in 2004, and in EURO there was an overall downward trend in dose distribution. The vast majority of countries cannot meet the 2003WHA coverage targets and are inadequately prepared for a global influenza pandemic. With only 5% of influenza vaccine doses being distributed to 50% of the world's population, there is urgency to redress the gross inequities in disease prevention and in pandemic preparedness. The 2003WHA resolution must be reviewed and revised and a call issued for the renewed commitment of Member States to influenza vaccination coverage targets. Copyright © 2017. Published by Elsevier Ltd.
Ward, Zoe; Platt, Lucy; Sweeney, Sedona; Hope, Vivian D; Maher, Lisa; Hutchinson, Sharon; Palmateer, Norah; Smith, Josie; Craine, Noel; Taylor, Avril; Martin, Natasha; Ayres, Rachel; Dillon, John; Hickman, Matthew; Vickerman, Peter
2018-05-17
To estimate the impact of existing high-coverage needle and syringe provision (HCNSP, defined as obtaining more than one sterile needle and syringe per injection reported) and opioid substitution therapy (OST) on hepatitis C virus (HCV) transmission among people who inject drugs (PWID) in three UK settings and to determine required scale-up of interventions, including HCV treatment, needed to reach the World Health Organization (WHO) target of reducing HCV incidence by 90% by 2030. HCV transmission modelling using UK empirical estimates for effect of OST and/or HCNSP on individual risk of HCV acquisition. Three UK cities with varying chronic HCV prevalence (Bristol 45%, Dundee 26%, Walsall 19%), OST (72-81%) and HCNSP coverage (28-56%). Relative change in new HCV infections throughout 2016-30 if current interventions were stopped. Scale-up of HCNSP, OST and HCV treatment required to achieve the WHO elimination target. Removing HCNSP or OST would increase the number of new HCV infections throughout 2016 to 2030 by 23-64 and 92-483%, respectively. Conversely, scaling-up these interventions to 80% coverage could achieve a 29 or 49% reduction in Bristol and Walsall, respectively, whereas Dundee may achieve a 90% decrease in incidence with current levels of intervention because of existing high levels of HCV treatment (47-58 treatments per 1000 PWID). If OST and HCNSP are scaled-up, Walsall and Bristol can achieve the same impact by treating 14 or 40 per 1000 PWID annually, respectively (currently two and nine treatments per 1000 PWID), while 18 and 43 treatments per 1000 PWID would be required if OST and HCNSP are not scaled-up. Current opioid substitution therapy and high-coverage needle and syringe provision coverage is averting substantial hepatitis C transmission in the United Kingdom. Maintaining this coverage while getting current drug injectors onto treatment can reduce incidence by 90% by 2030. © 2018 The Authors. Addiction published by John Wiley & Sons Ltd on behalf of Society for the Study of Addiction.
Using lot quality assurance sampling to improve immunization coverage in Bangladesh.
Tawfik, Y.; Hoque, S.; Siddiqi, M.
2001-01-01
OBJECTIVE: To determine areas of low vaccination coverage in five cities in Bangladesh (Chittagong, Dhaka, Khulna, Rajshahi, and Syedpur). METHODS: Six studies using lot quality assurance sampling were conducted between 1995 and 1997 by Basic Support for Institutionalizing Child Survival and the Bangladesh National Expanded Programme on Immunization. FINDINGS: BCG vaccination coverage was acceptable in all lots studied; however, the proportion of lots rejected because coverage of measles vaccination was low ranged from 0% of lots in Syedpur to 12% in Chittagong and 20% in Dhaka's zones 7 and 8. The proportion of lots rejected because an inadequate number of children in the sample had been fully vaccinated varied from 11% in Syedpur to 30% in Dhaka. Additionally, analysis of aggregated, weighted immunization coverage showed that there was a high BCG vaccination coverage (the first administered vaccine) and a low measles vaccination coverage (the last administered vaccine) indicating a high drop-out rate, ranging from 14% in Syedpur to 36% in Dhaka's zone 8. CONCLUSION: In Bangladesh, where resources are limited, results from surveys using lot quality assurance sampling enabled managers of the National Expanded Programme on Immunization to identify areas with poor vaccination coverage. Those areas were targeted to receive focused interventions to improve coverage. Since this sampling method requires only a small sample size and was easy for staff to use, it is feasible for routine monitoring of vaccination coverage. PMID:11436470
A novel probabilistic approach to generating PTV with partial voxel contributions
NASA Astrophysics Data System (ADS)
Tsang, H. S.; Kamerling, C. P.; Ziegenhein, P.; Nill, S.; Oelfke, U.
2017-06-01
Radiotherapy treatment planning for use with high-energy photon beams currently employs a binary approach in defining the planning target volume (PTV). We propose a margin concept that takes the beam directions into account, generating beam-dependent PTVs (bdPTVs) on a beam-by-beam basis. The resulting degree of overlaps between the bdPTVs are used within the optimisation process; the optimiser effectively considers the same voxel to be both target and organ at risk (OAR) with fractional contributions. We investigate the impact of this novel approach when applied to prostate radiotherapy treatments, and compare treatment plans generated using beam dependent margins to conventional margins. Five prostate patients were used in this planning study, and plans using beam dependent margins improved the sparing of high doses to target-surrounding OARs, though a trade-off in delivering additional low dose to the OARs can be observed. Plans using beam dependent margins are observed to have a slightly reduced target coverage. Nevertheless, all plans are able to satisfy 90% population coverage with the target receiving at least 95% of the prescribed dose to D98% .
22 CFR Appendix I to Part 211 - Operational Plan
Code of Federal Regulations, 2010 CFR
2010-04-01
.... If there are several objectives, indicate priorities. c. Describe the target population by program... coverage and the percent of total target population reached. d. Describe the intervention including: (1... World Food Program) emergency request normally requires more Mission involvement in program design and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burnum-Johnson, Kristin E.; Nie, Song; Casey, Cameron P.
Current proteomics approaches are comprised of both broad discovery measurements as well as more quantitative targeted measurements. These two different measurement types are used to initially identify potentially important proteins (e.g., candidate biomarkers) and then enable improved quantification for a limited number of selected proteins. However, both approaches suffer from limitations, particularly the lower sensitivity, accuracy, and quantitation precision for discovery approaches compared to targeted approaches, and the limited proteome coverage provided by targeted approaches. Herein, we describe a new proteomics approach that allows both discovery and targeted monitoring (DTM) in a single analysis using liquid chromatography, ion mobility spectrometrymore » and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled peptides for target ions are spiked into tryptic digests and both the labeled and unlabeled peptides are broadly detected using LC-IMS-MS instrumentation, allowing the benefits of discovery and targeted approaches. To understand the possible improvement of the DTM approach, it was compared to LC-MS broad measurements using an accurate mass and time tag database and selected reaction monitoring (SRM) targeted measurements. The DTM results yielded greater peptide/protein coverage and a significant improvement in the detection of lower abundance species compared to LC-MS discovery measurements. DTM was also observed to have similar detection limits as SRM for the targeted measurements indicating its potential for combining the discovery and targeted approaches.« less
NASA Astrophysics Data System (ADS)
Anderson, Monica; David, Phillip
2007-04-01
Implementation of an intelligent, automated target acquisition and tracking systems alleviates the need for operators to monitor video continuously. This system could identify situations that fatigued operators could easily miss. If an automated acquisition and tracking system plans motions to maximize a coverage metric, how does the performance of that system change when the user intervenes and manually moves the camera? How can the operator give input to the system about what is important and understand how that relates to the overall task balance between surveillance and coverage? In this paper, we address these issues by introducing a new formulation of the average linear uncovered length (ALUL) metric, specially designed for use in surveilling urban environments. This metric coordinates the often competing goals of acquiring new targets and tracking existing targets. In addition, it provides current system performance feedback to system users in terms of the system's theoretical maximum and minimum performance. We show the successful integration of the algorithm via simulation.
Hafiz, Israt; Berhan, Meklit; Keller, Angela; Haq, Rouseli; Chesnaye, Nicholas; Koporc, Kim; Rahman, Mujibur; Rahman, Shamsur; Mathieu, Els
2015-01-01
Bangladesh's national deworming program targets school-age children (SAC) through bi-annual school-based distributions of mebendazole. Qualitative and quantitative methods were applied to identify challenges related to treatment monitoring within the Munshiganj and Lakshmipur Districts of Bangladesh. Key stakeholder interviews identified several obstacles for successful treatment monitoring within these districts; ambiguity in defining the target population, variances in the methods used for compiling and reporting treatment data, and a general lack of financial and human resources. A treatment coverage cluster survey revealed that bi-annual primary school-based distributions proved to be an effective strategy in reaching school-attending SAC, with rates between 63.0% and 73.3%. However, the WHO target of regular treatment of at least 75% of SAC has yet to be reached. Particularly low coverage was seen amongst non-school attending children (11.4-14.3%), most likely due to the lack of national policy to effectively target this vulnerable group. Survey findings on water and sanitation coverage were impressive with the majority of households and schools having access to latrines (98.6-99.3%) and safe drinking water (98.2-100%). The challenge now for the Bangladesh control program is to achieve the WHO target of regular treatment of at least 75% of SAC at risk, irrespective of school-enrollment status. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
Brotherton, Julia M L; Bloem, Paul N
2018-02-01
Persistent oncogenic human papillomavirus (HPV) is the cause of cervical cancer, as well as cancers of the anus, penis, vulva, vagina and oropharynx. There is good evidence that prophylactic HPV vaccines are immunogenic and effective against targeted-type HPV infections and type-specific genital lesions, including high-grade cervical intraepithelial neoplasia (CIN), when administered prior to HPV infection. There is good evidence that HPV vaccines are safe in population usage, with the most frequent adverse event being injection-site reactions. There is evidence to support some cross-protection against non-targeted types occurring following the administration of HPV vaccines. There is limited evidence suggesting that HPV vaccines may be beneficial in preventing future disease in women treated for high-grade CIN. This chapter focuses on the accumulated evidence regarding the global use of the three licensed HPV vaccines including safety, immunogenicity, duration of protection, effectiveness, coverage to date and barriers to higher coverage. Copyright © 2018 Elsevier Ltd. All rights reserved.
Mars atmosphere studies with the SPICAM IR emission phase function observations
NASA Astrophysics Data System (ADS)
Trokhimovskiy, Alexander; Fedorova, Anna; Montmessin, Franck; Korablev, Oleg; Bertaux, Jean-Loup
Emission Phase Function (EPF) observations is a powerful tool for characterization of atmosphere and surface. EPF sequence provides the extensive coverage of scattering angles above the targeted surface location which allow to separate the surface and aerosol scattering, study a vertical distribution of minor species and aerosol properties. SPICAM IR instrument on Mars Express mission provides continuous atmospheric observations in near IR (1-1.7 mu) in nadir and limb starting from 2004. For the first years of SPICAM operation only a very limited number of EPFs was performed. But from the mid 2013 (Ls=225, MY31) SPICAM EPF observations become rather regular. Based on the multiple-scattering radiative transfer model SHDOM, we analyze equivalent depths of carbon dioxide (1,43 mu) and water vapour (1,38 mu) absorption bands and their dependence on airmass during observation sequence to get aerosol optical depths and properties. The derived seasonal dust opacities from near IR can be used to retrieve the size distribution from comparison with simultaneous results of other instruments in different spectral ranges. Moreover, the EPF observations of water vapour band allow to access poorly known H2O vertical distribution for different season and locations.
Pinchoff, Jessie; Larsen, David A; Renn, Silvia; Pollard, Derek; Fornadel, Christen; Maire, Mark; Sikaala, Chadwick; Sinyangwe, Chomba; Winters, Benjamin; Bridges, Daniel J; Winters, Anna M
2016-01-06
In Zambia and other sub-Saharan African countries affected by ongoing malaria transmission, indoor residual spraying (IRS) for malaria prevention has typically been implemented over large areas, e.g., district-wide, and targeted to peri-urban areas. However, there is a recent shift in some countries, including Zambia, towards the adoption of a more strategic and targeted IRS approach, in coordination with increased emphasis on universal coverage of long-lasting insecticidal nets (LLINs) and effective insecticide resistance management. A true targeted approach would deliver IRS to sub-district areas identified as high-risk, with the goal of maximizing the prevention of malaria cases and deaths. Together with the Government of the Republic of Zambia, a new methodology was developed applying geographic information systems and satellite imagery to support a targeted IRS campaign during the 2014 spray season using health management information system data. This case study focuses on the developed methodology while also highlighting the significant research gaps which must be filled to guide countries on the most effective strategy for IRS targeting in the context of universal LLIN coverage and evolving insecticide resistance.
Campos, Andre N.; Souza, Efren L.; Nakamura, Fabiola G.; Nakamura, Eduardo F.; Rodrigues, Joel J. P. C.
2012-01-01
Target tracking is an important application of wireless sensor networks. The networks' ability to locate and track an object is directed linked to the nodes' ability to locate themselves. Consequently, localization systems are essential for target tracking applications. In addition, sensor networks are often deployed in remote or hostile environments. Therefore, density control algorithms are used to increase network lifetime while maintaining its sensing capabilities. In this work, we analyze the impact of localization algorithms (RPE and DPE) and density control algorithms (GAF, A3 and OGDC) on target tracking applications. We adapt the density control algorithms to address the k-coverage problem. In addition, we analyze the impact of network density, residual integration with density control, and k-coverage on both target tracking accuracy and network lifetime. Our results show that DPE is a better choice for target tracking applications than RPE. Moreover, among the evaluated density control algorithms, OGDC is the best option among the three. Although the choice of the density control algorithm has little impact on the tracking precision, OGDC outperforms GAF and A3 in terms of tracking time. PMID:22969329
Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S
2015-04-01
Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.
NASA Astrophysics Data System (ADS)
Zamani, M.; Kasesaz, Y.; Khalafi, H.; Pooya, S. M. Hosseini
Boron Neutron Capture Therapy (BNCT) is used for treatment of many diseases, including brain tumors, in many medical centers. In this method, a target area (e.g., head of patient) is irradiated by some optimized and suitable neutron fields such as research nuclear reactors. Aiming at protection of healthy tissues which are located in the vicinity of irradiated tissue, and based on the ALARA principle, it is required to prevent unnecessary exposure of these vital organs. In this study, by using numerical simulation method (MCNP4C Code), the absorbed dose in target tissue and the equiavalent dose in different sensitive tissues of a patiant treated by BNCT, are calculated. For this purpose, we have used the parameters of MIRD Standard Phantom. Equiavelent dose in 11 sensitive organs, located in the vicinity of target, and total equivalent dose in whole body, have been calculated. The results show that the absorbed dose in tumor and normal tissue of brain equal to 30.35 Gy and 0.19 Gy, respectively. Also, total equivalent dose in 11 sensitive organs, other than tumor and normal tissue of brain, is equal to 14 mGy. The maximum equivalent doses in organs, other than brain and tumor, appear to the tissues of lungs and thyroid and are equal to 7.35 mSv and 3.00 mSv, respectively.
Confetti: A Multiprotease Map of the HeLa Proteome for Comprehensive Proteomics*
Guo, Xiaofeng; Trudgian, David C.; Lemoff, Andrew; Yadavalli, Sivaramakrishna; Mirzaei, Hamid
2014-01-01
Bottom-up proteomics largely relies on tryptic peptides for protein identification and quantification. Tryptic digestion often provides limited coverage of protein sequence because of issues such as peptide length, ionization efficiency, and post-translational modification colocalization. Unfortunately, a region of interest in a protein, for example, because of proximity to an active site or the presence of important post-translational modifications, may not be covered by tryptic peptides. Detection limits, quantification accuracy, and isoform differentiation can also be improved with greater sequence coverage. Selected reaction monitoring (SRM) would also greatly benefit from being able to identify additional targetable sequences. In an attempt to improve protein sequence coverage and to target regions of proteins that do not generate useful tryptic peptides, we deployed a multiprotease strategy on the HeLa proteome. First, we used seven commercially available enzymes in single, double, and triple enzyme combinations. A total of 48 digests were performed. 5223 proteins were detected by analyzing the unfractionated cell lysate digest directly; with 42% mean sequence coverage. Additional strong-anion exchange fractionation of the most complementary digests permitted identification of over 3000 more proteins, with improved mean sequence coverage. We then constructed a web application (https://proteomics.swmed.edu/confetti) that allows the community to examine a target protein or protein isoform in order to discover the enzyme or combination of enzymes that would yield peptides spanning a certain region of interest in the sequence. Finally, we examined the use of nontryptic digests for SRM. From our strong-anion exchange fractionation data, we were able to identify three or more proteotypic SRM candidates within a single digest for 6056 genes. Surprisingly, in 25% of these cases the digest producing the most observable proteotypic peptides was neither trypsin nor Lys-C. SRM analysis of Asp-N versus tryptic peptides for eight proteins determined that Asp-N yielded higher signal in five of eight cases. PMID:24696503
Influenza immunization among Canadian health care personnel: a cross-sectional study
Buchan, Sarah A.; Kwong, Jeffrey C.
2016-01-01
Background: Influenza immunization coverage among Canadian health care personnel remains below national targets. Targeting this group is of particular importance given their elevated risk of influenza infection, role in transmission and influence on patients' immunization status. We examined influenza immunization coverage in health care personnel in Canada, reasons for not being immunized and the impact of "vaccinate-or-mask" influenza prevention policies. Methods: In this national cross-sectional study, we pooled data from the 2007 to 2014 cycles of the Canadian Community Health Survey and restricted it to respondents who reported a health care occupation. Using bootstrapped survey weights, we examined immunization coverage by occupation and by presence of vaccinate-or-mask policies, and reasons for not being immunized. We used modified Poisson regression to estimate the prevalence ratio (PR) of influenza immunization for health care occupations compared with the general working population. Results: For all survey cycles combined, 50% of 18 446 health care personnel reported receiving seasonal influenza immunization during the previous 12 months, although this varied by occupation type (range 4%-72%). Compared with the general working population, family physicians and general practitioners were most likely to be immunized (PR 3.15, 95% confidence interval [CI] 2.76-3.59), whereas chiropractors, midwives and practitioners of natural healing were least likely (PR 0.17, 95% CI 0.10-0.30). Among those who were not immunized, the most frequently cited reason was the belief that influenza immunization is unnecessary. Introduction of vaccinate-or-mask policies was associated with increased influenza immunization among health care personnel. Interpretation: Health care personnel are more likely to be immunized against influenza than the general working population, but coverage remains suboptimal overall, and we observed wide variation by occupation type. More efforts are needed to target specific health care occupations with low immunization coverage. PMID:27730112
Strategies for Coordination of a Serosurvey in Parallel with an Immunization Coverage Survey
Travassos, Mark A.; Beyene, Berhane; Adam, Zenaw; Campbell, James D.; Mulholland, Nigisti; Diarra, Seydou S.; Kassa, Tassew; Oot, Lisa; Sequeira, Jenny; Reymann, Mardi; Blackwelder, William C.; Pasetti, Marcela F.; Sow, Samba O.; Steinglass, Robert; Kebede, Amha; Levine, Myron M.
2015-01-01
A community-based immunization coverage survey is the standard way to estimate effective vaccination delivery to a target population in a region. Accompanying serosurveys can provide objective measures of protective immunity against vaccine-preventable diseases but pose considerable challenges with respect to specimen collection and preservation and community compliance. We performed serosurveys coupled to immunization coverage surveys in three administrative districts (woredas) in rural Ethiopia. Critical to the success of this effort were serosurvey equipment and supplies, team composition, and tight coordination with the coverage survey. Application of these techniques to future studies may foster more widespread use of serosurveys to derive more objective assessments of vaccine-derived seroprotection and monitor and compare the performance of immunization services in different districts of a country. PMID:26055737
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Reid F.; Zhai, Huifang; Both, Stefan
Purpose: Uncontrolled local growth is the cause of death in ∼30% of patients with unresectable pancreatic cancers. The addition of standard-dose radiotherapy to gemcitabine has been shown to confer a modest survival benefit in this population. Radiation dose escalation with three-dimensional planning is not feasible, but high-dose intensity-modulated radiation therapy (IMRT) has been shown to improve local control. Still, dose-escalation remains limited by gastrointestinal toxicity. In this study, the authors investigate the potential use of double scattering (DS) and pencil beam scanning (PBS) proton therapy in limiting dose to critical organs at risk. Methods: The authors compared DS, PBS, andmore » IMRT plans in 13 patients with unresectable cancer of the pancreatic head, paying particular attention to duodenum, small intestine, stomach, liver, kidney, and cord constraints in addition to target volume coverage. All plans were calculated to 5500 cGy in 25 fractions with equivalent constraints and normalized to prescription dose. All statistics were by two-tailed paired t-test. Results: Both DS and PBS decreased stomach, duodenum, and small bowel dose in low-dose regions compared to IMRT (p < 0.01). However, protons yielded increased doses in the mid to high dose regions (e.g., 23.6–53.8 and 34.9–52.4 Gy for duodenum using DS and PBS, respectively; p < 0.05). Protons also increased generalized equivalent uniform dose to duodenum and stomach, however these differences were small (<5% and 10%, respectively; p < 0.01). Doses to other organs-at-risk were within institutional constraints and placed no obvious limitations on treatment planning. Conclusions: Proton therapy does not appear to reduce OAR volumes receiving high dose. Protons are able to reduce the treated volume receiving low-intermediate doses, however the clinical significance of this remains to be determined in future investigations.« less
McIntyre, Di; Ataguba, John E
2012-03-01
South Africa is considering introducing a universal health care system. A key concern for policy-makers and the general public is whether or not this reform is affordable. Modelling the resource and revenue generation requirements of alternative reform options is critical to inform decision-making. This paper considers three reform scenarios: universal coverage funded by increased allocations to health from general tax and additional dedicated taxes; an alternative reform option of extending private health insurance coverage to all formal sector workers and their dependents with the remainder using tax-funded services; and maintaining the status quo. Each scenario was modelled over a 15-year period using a spreadsheet model. Statistical analyses were also undertaken to evaluate the impact of options on the distribution of health care financing burden and benefits from using health services across socio-economic groups. Universal coverage would result in total health care spending levels equivalent to 8.6% of gross domestic product (GDP), which is comparable to current spending levels. It is lower than the status quo option (9.5% of GDP) and far lower than the option of expanding private insurance cover (over 13% of GDP). However, public funding of health services would have to increase substantially. Despite this, universal coverage would result in the most progressive financing system if the additional public funding requirements are generated through a surcharge on taxable income (but not if VAT is increased). The extended private insurance scheme option would be the least progressive and would impose a very high payment burden; total health care payments on average would be 10.7% of household consumption expenditure compared with the universal coverage (6.7%) and status quo (7.5%) options. The least pro-rich distribution of service benefits would be achieved under universal coverage. Universal coverage is affordable and would promote health system equity, but needs careful design to ensure its long-term sustainability.
Rinella, J.F.; Miller, T.L.
1988-01-01
Analysis of atmospheric precipitation samples, collected during the 1983 calendar year from 109 National Trends Network sites in the United States, are presented in this report. The sites were grouped into six geographical regions based on the chemical composition of the samples. Precipitation chemistry in these regions was influenced by proximity to (1) oceans, (2) major industrial and fossil-fuel consuming areas, and (3) major agricultural and livestock areas. Frequency distributions of ionic composition, determined on 10 chemical constituents and on precipitation quantities for each site, showed wide variations in chemical concentrations and precipitation quantities from site to site. Of the 109 sites, 55 had data coverage for the year sufficient to characterize precipitation quality patterns on a nationwide basis. Except for ammonium and calcium, both of which showed largest concentrations in the agricultural midwest and plains states, the largest concentrations and loads generally were in areas that include the heavily industrialized population center of the eastern United States. Except for hydrogen, all chemical ions are inversely related to the quantity of precipitation depth. Precipitation quantities generally account for less than 30% of chemical variation in precipitation samples. However, precipitation quantities account for 30 to 65% of the variations of calcium concentrations in precipitation. In regions where precipitation has a large ionic proportion of hydrogen-ion equivalents, much of the hydrogen-ion concentration could be balanced by sulfate equivalents and partly balanced by nitrite-plus-nitrate equivalents. In the regions where hydrogen-ion equivalents in precipitation were smaller, ammonion-and calcium-ion equivalents were necessary, along with the hydrogen-ion equivalents, to balance the sulfate plus nitrite-plus-nitrate equivalent. (USGS)
Abegunde, Dele; Orobaton, Nosa; Shoretire, Kamil; Ibrahim, Mohammed; Mohammed, Zainab; Abdulazeez, Jumare; Gwamzhi, Ringpon; Ganiyu, Akeem
2015-01-01
Maternal mortality ratio and infant mortality rate are as high as 1,576 per 100,000 live births and 78 per 1,000 live births, respectively, in Nigeria's northwestern region, where Sokoto State is located. Using applicable monitoring indicators for tracking progress in the UN/WHO framework on continuum of maternal, newborn, and child health care, this study evaluated the progress of Sokoto toward achieving the Millennium Development Goals (MDGs) 4 and 5 by December 2015. The changes in outcomes in 2012-2013 associated with maternal and child health interventions were assessed. We used baseline and follow-up lot quality assurance sampling (LQAS) data obtained in 2012 and 2013, respectively. In each of the surveys, data were obtained from 437 households sampled from 19 LQAS locations in each of the 23 local government areas (LGAs). The composite state-level coverage estimates of the respective indicators were aggregated from estimated LGA coverage estimates. None of the nine indicators associated with the continuum of maternal, neonatal, and child care satisfied the recommended 90% coverage target for achieving MDGs 4 and 5. Similarly, the average state coverage estimates were lower than national coverage estimates. Marginal improvements in coverage were obtained in the demand for family planning satisfied, antenatal care visits, postnatal care for mothers, and exclusive breast-feeding. Antibiotic treatment for acute pneumonia increased significantly by 12.8 percentage points. The majority of the LGAs were classifiable as low-performing, high-priority areas for intensified program intervention. Despite the limited time left in the countdown to December 2015, Sokoto State, Nigeria, is not on track to achieving the MDG 90% coverage of indicators tied to the continuum of maternal and child care, to reduce maternal and childhood mortality by a third by 2015. Targeted health system investments at the primary care level remain a priority, for intensive program scale-up to accelerate impact.
Abegunde, Dele; Orobaton, Nosa; Shoretire, Kamil; Ibrahim, Mohammed; Mohammed, Zainab; Abdulazeez, Jumare; Gwamzhi, Ringpon; Ganiyu, Akeem
2015-01-01
Background Maternal mortality ratio and infant mortality rate are as high as 1,576 per 100,000 live births and 78 per 1,000 live births, respectively, in Nigeria's northwestern region, where Sokoto State is located. Using applicable monitoring indicators for tracking progress in the UN/WHO framework on continuum of maternal, newborn, and child health care, this study evaluated the progress of Sokoto toward achieving the Millennium Development Goals (MDGs) 4 and 5 by December 2015. The changes in outcomes in 2012–2013 associated with maternal and child health interventions were assessed. Design We used baseline and follow-up lot quality assurance sampling (LQAS) data obtained in 2012 and 2013, respectively. In each of the surveys, data were obtained from 437 households sampled from 19 LQAS locations in each of the 23 local government areas (LGAs). The composite state-level coverage estimates of the respective indicators were aggregated from estimated LGA coverage estimates. Results None of the nine indicators associated with the continuum of maternal, neonatal, and child care satisfied the recommended 90% coverage target for achieving MDGs 4 and 5. Similarly, the average state coverage estimates were lower than national coverage estimates. Marginal improvements in coverage were obtained in the demand for family planning satisfied, antenatal care visits, postnatal care for mothers, and exclusive breast-feeding. Antibiotic treatment for acute pneumonia increased significantly by 12.8 percentage points. The majority of the LGAs were classifiable as low-performing, high-priority areas for intensified program intervention. Conclusions Despite the limited time left in the countdown to December 2015, Sokoto State, Nigeria, is not on track to achieving the MDG 90% coverage of indicators tied to the continuum of maternal and child care, to reduce maternal and childhood mortality by a third by 2015. Targeted health system investments at the primary care level remain a priority, for intensive program scale-up to accelerate impact. PMID:26455491
Development of Proportional Reasoning: Where Young Children Go Wrong
Boyer, Ty W.; Levine, Susan C.; Huttenlocher, Janellen
2008-01-01
Previous studies have found that children have difficulty solving proportional reasoning problems involving discrete units until 10- to 12-years of age, but can solve parallel problems involving continuous quantities by 6-years of age. The present studies examine where children go wrong in processing proportions that involve discrete quantities. A computerized proportional equivalence choice task was administered to kindergartners through fourth-graders in Study 1, and to first- and third-graders in Study 2. Both studies involved four between-subjects conditions that were formed by pairing continuous and discrete target proportions with continuous and discrete choice alternatives. In Study 1, target and choice alternatives were presented simultaneously and in Study 2 target and choice alternatives were presented sequentially. In both studies, children performed significantly worse when both the target and choice alternatives were represented with discrete quantities than when either or both of the proportions involved continuous quantities. Taken together, these findings indicate that children go astray on proportional reasoning problems involving discrete units only when a numerical match is possible, suggesting that their difficulty is due to an overextension of numerical equivalence concepts to proportional equivalence problems. PMID:18793078
Multiplex Degenerate Primer Design for Targeted Whole Genome Amplification of Many Viral Genomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gardner, Shea N.; Jaing, Crystal J.; Elsheikh, Maher M.
Background . Targeted enrichment improves coverage of highly mutable viruses at low concentration in complex samples. Degenerate primers that anneal to conserved regions can facilitate amplification of divergent, low concentration variants, even when the strain present is unknown. Results . A tool for designing multiplex sets of degenerate sequencing primers to tile overlapping amplicons across multiple whole genomes is described. The new script, run_tiled_primers, is part of the PriMux software. Primers were designed for each segment of South American hemorrhagic fever viruses, tick-borne encephalitis, Henipaviruses, Arenaviruses, Filoviruses, Crimean-Congo hemorrhagic fever virus, Rift Valley fever virus, and Japanese encephalitis virus. Eachmore » group is highly diverse with as little as 5% genome consensus. Primer sets were computationally checked for nontarget cross reactions against the NCBI nucleotide sequence database. Primers for murine hepatitis virus were demonstrated in the lab to specifically amplify selected genes from a laboratory cultured strain that had undergone extensive passage in vitro and in vivo. Conclusions . This software should help researchers design multiplex sets of primers for targeted whole genome enrichment prior to sequencing to obtain better coverage of low titer, divergent viruses. Applications include viral discovery from a complex background and improved sensitivity and coverage of rapidly evolving strains or variants in a gene family.« less