Sample records for equivalent temperature pet

  1. Modified physiologically equivalent temperature—basics and applications for western European climate

    NASA Astrophysics Data System (ADS)

    Chen, Yung-Chang; Matzarakis, Andreas

    2018-05-01

    A new thermal index, the modified physiologically equivalent temperature (mPET) has been developed for universal application in different climate zones. The mPET has been improved against the weaknesses of the original physiologically equivalent temperature (PET) by enhancing evaluation of the humidity and clothing variability. The principles of mPET and differences between original PET and mPET are introduced and discussed in this study. Furthermore, this study has also evidenced the usability of mPET with climatic data in Freiburg, which is located in Western Europe. Comparisons of PET, mPET, and Universal Thermal Climate Index (UTCI) have shown that mPET gives a more realistic estimation of human thermal sensation than the other two thermal indices (PET, UTCI) for the thermal conditions in Freiburg. Additionally, a comparison of physiological parameters between mPET model and PET model (Munich Energy Balance Model for Individual, namely MEMI) is proposed. The core temperatures and skin temperatures of PET model vary more violently to a low temperature during cold stress than the mPET model. It can be regarded as that the mPET model gives a more realistic core temperature and mean skin temperature than the PET model. Statistical regression analysis of mPET based on the air temperature, mean radiant temperature, vapor pressure, and wind speed has been carried out. The R square (0.995) has shown a well co-relationship between human biometeorological factors and mPET. The regression coefficient of each factor represents the influence of the each factor on changing mPET (i.e., ±1 °C of T a = ± 0.54 °C of mPET). The first-order regression has been considered predicting a more realistic estimation of mPET at Freiburg during 2003 than the other higher order regression model, because the predicted mPET from the first-order regression has less difference from mPET calculated from measurement data. Statistic tests recognize that mPET can effectively evaluate the influences of all human biometeorological factors on thermal environments. Moreover, a first-order regression function can also predict the thermal evaluations of the mPET by using human biometeorological factors in Freiburg.

  2. The potential of a modified physiologically equivalent temperature (mPET) based on local thermal comfort perception in hot and humid regions

    NASA Astrophysics Data System (ADS)

    Lin, Tzu-Ping; Yang, Shing-Ru; Chen, Yung-Chang; Matzarakis, Andreas

    2018-02-01

    Physiologically equivalent temperature (PET) is a thermal index that is widely used in the field of human biometeorology and urban bioclimate. However, it has several limitations, including its poor ability to predict thermo-physiological parameters and its weak response to both clothing insulation and humid conditions. A modified PET (mPET) was therefore developed to address these shortcomings. To determine whether the application of mPET in hot-humid regions is more appropriate than the PET, an analysis of a thermal comfort survey database, containing 2071 questionnaires collected from participants in hot-humid Taiwan, was conducted. The results indicate that the thermal comfort range is similar (26-30 °C) when the mPET and PET are applied as thermal indices to the database. The sensitivity test for vapor pressure and clothing insulation also show that the mPET responds well to the behavior and perceptions of local people in a subtropical climate.

  3. Protonation Studies of a Tungsten Dinitrogen Complex Supported by a Diphosphine Ligand Containing a Pendant Amine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weiss, Charles J.; Egbert, Jonathan D.; Chen, Shentan

    2014-04-28

    Treatment of trans-[W(N2)2(dppe)(PEtNMePEt)] (dppe = Ph2PCH2CH2PPh2; PEtNMePEt = Et2PCH2N(Me)CH2PEt2) with three equivalents of tetrafluoroboric acid (HBF4∙Et2O) at -78 °C generated the seven-coordinate tungsten hydride trans-[W(N2)2(H)(dppe)(PEtNMePEt)][BF4]. Depending on the temperature of the reaction, protonation of a pendant amine is also observed, affording trans-[W(N2)2(H)(dppe)(PEtNMe(H)PEt)][BF4]2, with formation of the hydrazido complex, [W(NNH2)(dppe)(PEtNMe(H)PEt)][BF4]2, as a minor product. Similar product mixtures were obtained using triflic acid (HOTf). Upon acid addition to the carbonyl analogue, cis-[W(CO)2(dppe)(PEtNMePEt)], the seven-coordinate carbonyl-hydride complex, trans-[W(CO)2(H)(dppe)(PEtN(H)MePEt)][OTf]2 was generated. The mixed diphosphine complex without the pendant amine in the ligand backbone, trans-[W(N2)2(dppe)(depp)] (depp = Et2P(CH2)3PEt2), was synthesized and treated with HBF4∙Et2O, selectivelymore » generating a hydrazido complex, [W(NNH2)(F)(dppe)(depp)][BF4]. Computational analysis was used to probe proton affinity of three sites of protonation, the metal, pendant amine, and N2 ligand in these complexes. Room temperature reactions with 100 equivalents of HOTf produced NH4+ from reduction of the N2 ligand (electrons come from W). The addition of 100 equivalents HOTf to trans-[W(N2)2(dppe)(PEtNMePEt)] afforded 0.88 ± 0.02 equivalents NH4+, while 0.36 ± 0.02 equivalents of NH4+was formed upon treatment of trans-[W(N2)2(dppe)(depp)], the complex without the pendant amine. This work was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy Office of Science, Office of Basic Energy Sciences. Computational resources were provided by the National Energy Research Scientific Computing Center (NERSC) at Lawrence Berkeley National Laboratory. Pacific Northwest National Laboratory is operated by Battelle for DOE.« less

  4. Physiological Equivalent Temperature Index and mortality in Tabriz (The northwest of Iran).

    PubMed

    Sharafkhani, Rahim; Khanjani, Narges; Bakhtiari, Bahram; Jahani, Yunes; Sadegh Tabrizi, Jafar

    2018-01-01

    There are few epidemiological studies about climate change and the effect of temperature variation on health using human thermal indices such as the Physiological Equivalent Temperature (PET) Index in Iran. This study was conducted in Tabriz, the northwest of Iran and Distributed Lag Non-linear Models (DLNM) combined with quasi-Poisson regression models were used to assess the impacts of PET on mortality by using the DLNM Package in R Software. The effect of air pollutants, time trend, day of the week and holidays were controlled as confounders. There was a significant relation between high (30°C, 27°C) and low (-0.8°C, -9.2°C and -14.2°C) PET and total (non-accidental) mortality; and a significant increase in respiratory and cardiovascular deaths in high PET values. Heat stress increased Cumulative Relative Risk (CRR) for total (non-accidental), respiratory and cardiovascular mortality significantly (CRR Non Accidental Death, PET=30°C, lag 0-30 =1.67, 95%CI: 1.31-2.13; CRR Respiratory Death, PET=30°C, lag 0-13 =1.88, 95%CI: 1.30-2.72; CRR Cardiovascular Death, PET=30°C, lag0-30 =1.67 95%CI: 1.16-2.40). Heat stress increases the risk of total (non-accidental), respiratory mortality, but cold stress decreases the risk of total (non-accidental) mortality in Tabriz which is one of the cold cities of Iran. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The physiological equivalent temperature - a universal index for the biometeorological assessment of the thermal environment

    NASA Astrophysics Data System (ADS)

    Höppe, P.

    With considerably increased coverage of weather information in the news media in recent years in many countries, there is also more demand for data that are applicable and useful for everyday life. Both the perception of the thermal component of weather as well as the appropriate clothing for thermal comfort result from the integral effects of all meteorological parameters relevant for heat exchange between the body and its environment. Regulatory physiological processes can affect the relative importance of meteorological parameters, e.g. wind velocity becomes more important when the body is sweating. In order to take into account all these factors, it is necessary to use a heat-balance model of the human body. The physiological equivalent temperature (PET) is based on the Munich Energy-balance Model for Individuals (MEMI), which models the thermal conditions of the human body in a physiologically relevant way. PET is defined as the air temperature at which, in a typical indoor setting (without wind and solar radiation), the heat budget of the human body is balanced with the same core and skin temperature as under the complex outdoor conditions to be assessed. This way PET enables a layperson to compare the integral effects of complex thermal conditions outside with his or her own experience indoors. On hot summer days, for example, with direct solar irradiation the PET value may be more than 20 K higher than the air temperature, on a windy day in winter up to 15 K lower.

  6. Calibration of the physiological equivalent temperature index for three different climatic regions

    NASA Astrophysics Data System (ADS)

    Krüger, E.; Rossi, F.; Drach, P.

    2017-07-01

    In human biometeorology, the integration of several microclimatic variables as a combined index facilitates the understanding of how users perceive thermal environments. Indices, such as the physiological equivalent temperature (PET) index, translate the combined effects of meteorological variables on humans in terms of thermal stress or comfort and serve as important aids to climate-responsive urban and regional planning as well as heat stress and thermal comfort analyses. However, there is a need for adjusting proposed comfort/stress ranges of a given index when using it in different climatic contexts. The purpose of this study is to present a preliminary calibration procedure for the PET index for three different climatic regions: Curitiba, Brazil, a subtropical location; Rio de Janeiro, Brazil, a tropical city; and Glasgow, UK, a high-latitude location. Field studies have been carried out by the authors according to a similar protocol and using similar equipment, yielding actual thermal sensation votes and microclimate data, post-processed as PET data. The calibration procedure uses exclusively thermal sensation data as reported by pedestrians during outdoor comfort campaigns and concurrent microclimatic data recorded during the interviews. PET comfort/stress classes differ among the three locations and, in general, are less restrictive as in the original ranges proposed by the index developers.

  7. Beyond annual streamflow reconstructions for the Upper Colorado River Basin: a paleo-water-balance approach

    USGS Publications Warehouse

    Gangopadhyay, Subhrendu; McCabe, Gregory J.; Woodhouse, Connie A.

    2015-01-01

    In this paper, we present a methodology to use annual tree-ring chronologies and a monthly water balance model to generate annual reconstructions of water balance variables (e.g., potential evapotrans- piration (PET), actual evapotranspiration (AET), snow water equivalent (SWE), soil moisture storage (SMS), and runoff (R)). The method involves resampling monthly temperature and precipitation from the instrumental record directed by variability indicated by the paleoclimate record. The generated time series of monthly temperature and precipitation are subsequently used as inputs to a monthly water balance model. The methodology is applied to the Upper Colorado River Basin, and results indicate that the methodology reliably simulates water-year runoff, maximum snow water equivalent, and seasonal soil moisture storage for the instrumental period. As a final application, the methodology is used to produce time series of PET, AET, SWE, SMS, and R for the 1404–1905 period for the Upper Colorado River Basin.

  8. Subjective estimation of thermal environment in recreational urban spaces—Part 1: investigations in Szeged, Hungary

    NASA Astrophysics Data System (ADS)

    Kántor, Noémi; Égerházi, Lilla; Unger, János

    2012-11-01

    During two investigation periods in transient seasons (14 weekdays in autumn 2009 and 15 weekdays in spring 2010) 967 visitors in two inner city squares of Szeged (Hungary) were asked about their estimation of their thermal environment. Interrelationships of subjective assessments—thermal sensation, perceptions and preferences for individual climate parameters—were analyzed, as well as their connections with the prevailing thermal conditions [air temperature, relative humidity, wind velocity, mean radiant temperature and physiologically equivalent temperature (PET)]. Thermal sensation showed strong positive relationships with air temperature and solar radiation perception, while wind velocity and air humidity perception had a negative (and weaker) impact. If a parameter was perceived to be low or weak, then it was usually desired to be higher or stronger. This negative correlation was weakest in the case of humidity. Of the basic meteorological parameters, Hungarians are most sensitive to variations in wind. Above PET = 29°C, people usually prefer lower air temperature and less solar radiation. The temperature values perceived by the interviewees correlated stronger with PET, but their means were more similar to air temperature. It was also found that the mean thermal sensation of Hungarians in transient seasons depends on PET according to a quadratic function ( R 2 = 0.912) and, consequently, the thermal comfort ranges of the locals differ from that usually adopted.

  9. The effect of air temperature and human thermal indices on mortality in Athens, Greece

    NASA Astrophysics Data System (ADS)

    Nastos, Panagiotis T.; Matzarakis, Andreas

    2012-05-01

    This paper investigates whether there is any association between the daily mortality for the wider region of Athens, Greece and the thermal conditions, for the 10-year period 1992-2001. The daily mortality datasets were acquired from the Hellenic Statistical Service and the daily meteorological datasets, concerning daily maximum and minimum air temperature, from the Hellinikon/Athens meteorological station, established at the headquarters of the Greek Meteorological Service. Besides, the daily values of the thermal indices Physiologically Equivalent Temperature (PET) and Universal Thermal Climate Index (UTCI) were evaluated in order to interpret the grade of physiological stress. The first step was the application of Pearson's χ 2 test to the compiled contingency tables, resulting in that the probability of independence is zero ( p = 0.000); namely, mortality is in close relation to the air temperature and PET/UTCI. Furthermore, the findings extracted by the generalized linear models showed that, statistically significant relationships ( p < 0.01) between air temperature, PET, UTCI and mortality exist on the same day. More concretely, on one hand during the cold period (October-March), a 10°C decrease in daily maximum air temperature, minimum air temperature, temperature range, PET and UTCI is related with an increase 13%, 15%, 2%, 7% and 6% of the probability having a death, respectively. On the other hand, during the warm period (April-September), a 10°C increase in daily maximum air temperature, minimum air temperature, temperature range, PET and UTCI is related with an increase 3%, 1%, 10%, 3% and 5% of the probability having a death, respectively. Taking into consideration the time lag effect of the examined parameters on mortality, it was found that significant effects of 3-day lag during the cold period appears against 1-day lag during the warm period. In spite of the general aspect that cold conditions seem to be favourable factors for daily mortality, the air temperature and PET/UTCI exceedances over specific thresholds depending on the distribution reveal that, very hot conditions are risk factors for the daily mortality.

  10. Quantification and assessment of heat and cold waves in Novi Sad, Northern Serbia

    NASA Astrophysics Data System (ADS)

    Basarin, Biljana; Lukić, Tin; Matzarakis, Andreas

    2016-01-01

    Physiologically equivalent temperature (PET) has been applied to the analysis of heat and cold waves and human thermal conditions in Novi Sad, Serbia. A series of daily minimum and maximum air temperature, relative humidity, wind, and cloud cover was used to calculate PET for the investigated period 1949-2012. The heat and cold wave analysis was carried out on days with PET values exceeding defined thresholds. Additionally, the acclimatization approach was introduced to evaluate human adaptation to interannual thermal perception. Trend analysis has revealed the presence of increasing trend in summer PET anomalies, number of days above defined threshold, number of heat waves, and average duration of heat waves per year since 1981. Moreover, winter PET anomaly as well as the number of days below certain threshold and number of cold waves per year until 1980 was decreasing, but the decrease was not statistically significant. The highest number of heat waves during summer was registered in the last two decades, but also in the first decade of the investigated period. On the other hand, the number of cold waves during six decades is quite similar and the differences are very small.

  11. Quantification and assessment of heat and cold waves in Novi Sad, Northern Serbia.

    PubMed

    Basarin, Biljana; Lukić, Tin; Matzarakis, Andreas

    2016-01-01

    Physiologically equivalent temperature (PET) has been applied to the analysis of heat and cold waves and human thermal conditions in Novi Sad, Serbia. A series of daily minimum and maximum air temperature, relative humidity, wind, and cloud cover was used to calculate PET for the investigated period 1949-2012. The heat and cold wave analysis was carried out on days with PET values exceeding defined thresholds. Additionally, the acclimatization approach was introduced to evaluate human adaptation to interannual thermal perception. Trend analysis has revealed the presence of increasing trend in summer PET anomalies, number of days above defined threshold, number of heat waves, and average duration of heat waves per year since 1981. Moreover, winter PET anomaly as well as the number of days below certain threshold and number of cold waves per year until 1980 was decreasing, but the decrease was not statistically significant. The highest number of heat waves during summer was registered in the last two decades, but also in the first decade of the investigated period. On the other hand, the number of cold waves during six decades is quite similar and the differences are very small.

  12. Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ko, Guen Bae; Kim, Kyeong Yun; Yoon, Hyun Suk

    2016-01-15

    Purpose: In this study, the authors present a silicon photomultiplier (SiPM)-based positron emission tomography (PET) insert dedicated to small animal imaging with high system performance and robustness to temperature change. Methods: The insert consists of 64 LYSO-SiPM detector blocks arranged in 4 rings of 16 detector blocks to yield a ring diameter of 64 mm and axial field of view of 55 mm. Each detector block consists of a 9 × 9 array of LYSO crystals (1.2 × 1.2 × 10 mm{sup 3}) and a monolithic 4 × 4 SiPM array. The temperature of each monolithic SiPM is monitored, andmore » the proper bias voltage is applied according to the temperature reading in real time to maintain uniform performance. The performance of this PET insert was characterized using National Electrical Manufacturers Association NU 4-2008 standards, and its feasibility was evaluated through in vivo mouse imaging studies. Results: The PET insert had a peak sensitivity of 3.4% and volumetric spatial resolutions of 1.92 (filtered back projection) and 0.53 (ordered subset expectation maximization) mm{sup 3} at center. The peak noise equivalent count rate and scatter fraction were 42.4 kcps at 15.08 MBq and 16.5%, respectively. By applying the real-time bias voltage adjustment, an energy resolution of 14.2% ± 0.3% was maintained and the count rate varied ≤1.2%, despite severe temperature changes (10–30 °C). The mouse imaging studies demonstrate that this PET insert can produce high-quality images useful for imaging studies on the small animals. Conclusions: The developed MR-compatible PET insert is designed for insertion into a narrow-bore magnetic resonance imaging scanner, and it provides excellent imaging performance for PET/MR preclinical studies.« less

  13. Development and application of artificial neural network models to estimate values of a complex human thermal comfort index associated with urban heat and cool island patterns using air temperature data from a standard meteorological station

    NASA Astrophysics Data System (ADS)

    Moustris, Konstantinos; Tsiros, Ioannis X.; Tseliou, Areti; Nastos, Panagiotis

    2018-04-01

    The present study deals with the development and application of artificial neural network models (ANNs) to estimate the values of a complex human thermal comfort-discomfort index associated with urban heat and cool island conditions inside various urban clusters using as only inputs air temperature data from a standard meteorological station. The index used in the study is the Physiologically Equivalent Temperature (PET) index which requires as inputs, among others, air temperature, relative humidity, wind speed, and radiation (short- and long-wave components). For the estimation of PET hourly values, ANN models were developed, appropriately trained, and tested. Model results are compared to values calculated by the PET index based on field monitoring data for various urban clusters (street, square, park, courtyard, and gallery) in the city of Athens (Greece) during an extreme hot weather summer period. For the evaluation of the predictive ability of the developed ANN models, several statistical evaluation indices were applied: the mean bias error, the root mean square error, the index of agreement, the coefficient of determination, the true predictive rate, the false alarm rate, and the Success Index. According to the results, it seems that ANNs present a remarkable ability to estimate hourly PET values within various urban clusters using only hourly values of air temperature. This is very important in cases where the human thermal comfort-discomfort conditions have to be analyzed and the only available parameter is air temperature.

  14. Development and application of artificial neural network models to estimate values of a complex human thermal comfort index associated with urban heat and cool island patterns using air temperature data from a standard meteorological station.

    PubMed

    Moustris, Konstantinos; Tsiros, Ioannis X; Tseliou, Areti; Nastos, Panagiotis

    2018-04-11

    The present study deals with the development and application of artificial neural network models (ANNs) to estimate the values of a complex human thermal comfort-discomfort index associated with urban heat and cool island conditions inside various urban clusters using as only inputs air temperature data from a standard meteorological station. The index used in the study is the Physiologically Equivalent Temperature (PET) index which requires as inputs, among others, air temperature, relative humidity, wind speed, and radiation (short- and long-wave components). For the estimation of PET hourly values, ANN models were developed, appropriately trained, and tested. Model results are compared to values calculated by the PET index based on field monitoring data for various urban clusters (street, square, park, courtyard, and gallery) in the city of Athens (Greece) during an extreme hot weather summer period. For the evaluation of the predictive ability of the developed ANN models, several statistical evaluation indices were applied: the mean bias error, the root mean square error, the index of agreement, the coefficient of determination, the true predictive rate, the false alarm rate, and the Success Index. According to the results, it seems that ANNs present a remarkable ability to estimate hourly PET values within various urban clusters using only hourly values of air temperature. This is very important in cases where the human thermal comfort-discomfort conditions have to be analyzed and the only available parameter is air temperature.

  15. Monitoring proton radiation therapy with in-room PET imaging

    NASA Astrophysics Data System (ADS)

    Zhu, Xuping; España, Samuel; Daartz, Juliane; Liebsch, Norbert; Ouyang, Jinsong; Paganetti, Harald; Bortfeld, Thomas R.; El Fakhri, Georges

    2011-07-01

    We used a mobile positron emission tomography (PET) scanner positioned within the proton therapy treatment room to study the feasibility of proton range verification with an in-room, stand-alone PET system, and compared with off-line equivalent studies. Two subjects with adenoid cystic carcinoma were enrolled into a pilot study in which in-room PET scans were acquired in list-mode after a routine fractionated treatment session. The list-mode PET data were reconstructed with different time schemes to generate in-room short, in-room long and off-line equivalent (by skipping coincidences from the first 15 min during the list-mode reconstruction) PET images for comparison in activity distribution patterns. A phantom study was followed to evaluate the accuracy of range verification for different reconstruction time schemes quantitatively. The in-room PET has a higher sensitivity compared to the off-line modality so that the PET acquisition time can be greatly reduced from 30 to <5 min. Features in deep-site, soft-tissue regions were better retained with in-room short PET acquisitions because of the collection of 15O component and lower biological washout. For soft tissue-equivalent material, the distal fall-off edge of an in-room short acquisition is deeper compared to an off-line equivalent scan, indicating a better coverage of the high-dose end of the beam. In-room PET is a promising low cost, high sensitivity modality for the in vivo verification of proton therapy. Better accuracy in Monte Carlo predictions, especially for biological decay modeling, is necessary.

  16. Evaluation of human thermal comfort ranges in urban climate of winter cities on the example of Erzurum city.

    PubMed

    Toy, Süleyman; Kántor, Noémi

    2017-01-01

    Human thermal comfort conditions can be evaluated using various indices based on simple empirical approaches or more complex and reliable human-biometeorological approaches. The latter is based on the energy balance model of the human body, and their calculation is supplemented with computer software. Facilitating the interpretation of results, the generally applied indices express the effects of thermal environment in the well-known temperature unit, just like in the case of the widely used index, the physiologically equivalent temperature (PET). Several studies adopting PET index for characterizing thermal components of climate preferred to organize the resulted PET values into thermal sensation categories in order to demonstrate the spatial and/or temporal characteristics of human thermal comfort conditions. The most general applied PET ranges were derived by Central European researchers, and they are valid for assumed values of internal heat production of light activity and thermal resistance of clothing representing a light business suit. Based on the example of Erzurum city, the present work demonstrates that in a city with harsh winter, the original PET ranges show almost purely discomfort and they seem to be less applicable regarding cold climate conditions. Taking into account 34-year climate data of Erzurum, the annual distribution of PET is presented together with the impact of application of different PET categorization systems, including 8°- and 7°-wide PET intervals. The demonstrated prior analyses lack any questionnaire filed surveys in Erzurum. Thus, as a next step, detailed field investigations would be required with the aim of definition of new PET categorization systems which are relevant for local residents who are adapted to this climatic background, and for tourists who may perform various kinds of winter activities in Erzurum and therefore may perceive the thermal environment more comfortable.

  17. Thermal sensation and climate: a comparison of UTCI and PET thresholds in different climates

    NASA Astrophysics Data System (ADS)

    Pantavou, Katerina; Lykoudis, Spyridon; Nikolopoulou, Marialena; Tsiros, Ioannis X.

    2018-06-01

    The influence of physiological acclimatization and psychological adaptation on thermal perception is well documented and has revealed the importance of thermal experience and expectation in the evaluation of environmental stimuli. Seasonal patterns of thermal perception have been studied, and calibrated thermal indices' scales have been proposed to obtain meaningful interpretations of thermal sensation indices in different climate regions. The current work attempts to quantify the contribution of climate to the long-term thermal adaptation by examining the relationship between climate normal annual air temperature (1971-2000) and such climate-calibrated thermal indices' assessment scales. The thermal sensation ranges of two thermal indices, the Universal Thermal Climate Index (UTCI) and the Physiological Equivalent Temperature Index (PET), were calibrated for three warm temperate climate contexts (Cfa, Cfb, Csa), against the subjective evaluation of the thermal environment indicated by interviewees during field surveys conducted at seven European cities: Athens (GR), Thessaloniki (GR), Milan (IT), Fribourg (CH), Kassel (DE), Cambridge (UK), and Sheffield (UK), under the same research protocol. Then, calibrated scales for other climate contexts were added from the literature, and the relationship between the respective scales' thresholds and climate normal annual air temperature was examined. To maintain the maximum possible comparability, three methods were applied for the calibration, namely linear, ordinal, and probit regression. The results indicated that the calibrated UTCI and PET thresholds increase with the climate normal annual air temperature of the survey city. To investigate further climates, we also included in the analysis results of previous studies presenting only thresholds for neutral thermal sensation. The average increase of the respective thresholds in the case of neutral thermal sensation was about 0.6 °C for each 1 °C increase of the normal annual air temperature for both indices, statistically significant only for PET though.

  18. Influence of sky view factor on outdoor thermal environment and physiological equivalent temperature

    NASA Astrophysics Data System (ADS)

    He, Xiaodong; Miao, Shiguang; Shen, Shuanghe; Li, Ju; Zhang, Benzhi; Zhang, Ziyue; Chen, Xiujie

    2015-03-01

    Sky view factor (SVF), which is an indicator of urban canyon geometry, affects the surface energy balance, local air circulation, and outdoor thermal comfort. This study focused on a continuous and long-term meteorological observation system to investigate the effects of SVF on outdoor thermal conditions and physiological equivalent temperature (PET) in the central business district (CBD) of Beijing (which is located within Chaoyang District), specifically addressed current knowledge gaps for SVF-PET relationships in cities with typical continental/microthermal climates. An urban sub-domain scale model and the RayMan model were used to diagnose wind fields and to calculate SVF and long-term PET, respectively. Analytical results show that the extent of shading contributes to variations in thermal perception distribution. Highly shaded areas (SVF <0.3) typically exhibit less frequent hot conditions during summer, while enduring longer periods of cold discomfort in winter than moderately shaded areas (0.3< SVF <0.5) and slightly shaded areas (SVF >0.5), and vice versa. Because Beijing has a monsoon-influenced humid continental climate with hot summers and long, cold, windy, and dry winters, a design project that ideally provides moderate shading should be planned to balance hot discomfort in summer and cold discomfort in winter, which effectively prolongs the comfort periods in outdoor spaces throughout the entire year. This research indicate that climate zone characteristics, urban environmental conditions, and thermal comfort requirements of residents must be accounted for in local-scale scientific planning and design, i.e., for urban canyon streets and residential estates.

  19. A quantitative sensitivity analysis on the behaviour of common thermal indices under hot and windy conditions in Doha, Qatar

    NASA Astrophysics Data System (ADS)

    Fröhlich, Dominik; Matzarakis, Andreas

    2016-04-01

    Human thermal perception is best described through thermal indices. The most popular thermal indices applied in human bioclimatology are the perceived temperature (PT), the Universal Thermal Climate Index (UTCI), and the physiologically equivalent temperature (PET). They are analysed focusing on their sensitivity to single meteorological input parameters under the hot and windy meteorological conditions observed in Doha, Qatar. It can be noted, that the results for the three indices are distributed quite differently. Furthermore, they respond quite differently to modifications in the input conditions. All of them show particular limitations and shortcomings that have to be considered and discussed. While the results for PT are unevenly distributed, UTCI shows limitations concerning the input data accepted. PET seems to respond insufficiently to changes in vapour pressure. The indices should therefore be improved to be valid for several kinds of climates.

  20. Outdoor thermal comfort in public space in warm-humid Guayaquil, Ecuador

    NASA Astrophysics Data System (ADS)

    Johansson, Erik; Yahia, Moohammed Wasim; Arroyo, Ivette; Bengs, Christer

    2018-03-01

    The thermal environment outdoors affects human comfort and health. Mental and physical performance is reduced at high levels of air temperature being a problem especially in tropical climates. This paper deals with human comfort in the warm-humid city of Guayaquil, Ecuador. The main aim was to examine the influence of urban micrometeorological conditions on people's subjective thermal perception and to compare it with two thermal comfort indices: the physiologically equivalent temperature (PET) and the standard effective temperature (SET*). The outdoor thermal comfort was assessed through micrometeorological measurements of air temperature, humidity, mean radiant temperature and wind speed together with a questionnaire survey consisting of 544 interviews conducted in five public places of the city during both the dry and rainy seasons. The neutral and preferred values as well as the upper comfort limits of PET and SET* were determined. For both indices, the neutral values and upper thermal comfort limits were lower during the rainy season, whereas the preferred values were higher during the rainy season. Regardless of season, the neutral values of PET and SET* are above the theoretical neutral value of each index. The results show that local people accept thermal conditions which are above acceptable comfort limits in temperate climates and that the subjective thermal perception varies within a wide range. It is clear, however, that the majority of the people in Guayaquil experience the outdoor thermal environment during daytime as too warm, and therefore, it is important to promote an urban design which creates shade and ventilation.

  1. Outdoor thermal comfort in public space in warm-humid Guayaquil, Ecuador.

    PubMed

    Johansson, Erik; Yahia, Moohammed Wasim; Arroyo, Ivette; Bengs, Christer

    2018-03-01

    The thermal environment outdoors affects human comfort and health. Mental and physical performance is reduced at high levels of air temperature being a problem especially in tropical climates. This paper deals with human comfort in the warm-humid city of Guayaquil, Ecuador. The main aim was to examine the influence of urban micrometeorological conditions on people's subjective thermal perception and to compare it with two thermal comfort indices: the physiologically equivalent temperature (PET) and the standard effective temperature (SET*). The outdoor thermal comfort was assessed through micrometeorological measurements of air temperature, humidity, mean radiant temperature and wind speed together with a questionnaire survey consisting of 544 interviews conducted in five public places of the city during both the dry and rainy seasons. The neutral and preferred values as well as the upper comfort limits of PET and SET* were determined. For both indices, the neutral values and upper thermal comfort limits were lower during the rainy season, whereas the preferred values were higher during the rainy season. Regardless of season, the neutral values of PET and SET* are above the theoretical neutral value of each index. The results show that local people accept thermal conditions which are above acceptable comfort limits in temperate climates and that the subjective thermal perception varies within a wide range. It is clear, however, that the majority of the people in Guayaquil experience the outdoor thermal environment during daytime as too warm, and therefore, it is important to promote an urban design which creates shade and ventilation.

  2. Assessment of thermal comfort level at pedestrian level in high-density urban area of Hong Kong

    NASA Astrophysics Data System (ADS)

    Ma, J.; Ng, E.; Yuan, C.; Lai, A.

    2015-12-01

    Hong Kong is a subtropical city which is very hot and humid in the summer. Pedestrians commonly experience thermal discomfort. Various studies have shown that the tall bulky buildings intensify the urban heat island effect and reduce urban air ventilation. However, relatively few studies have focused on modeling the thermal load at pedestrian level (~ 2 m). This study assesses the thermal comfort level, quantified by PET (Physiological Equivalent Temperature), using a GIS - based simulation approach. A thermal comfort level map shows the PET value of a typical summer afternoon in the high building density area. For example, the averaged PET in Sheung Wan is about 41 degree Celsius in a clear day and 38 degree Celsius in a cloudy day. This map shows where the walkways, colonnades, and greening is most needed. In addition, given a start point, a end point, and weather data, we generate the most comfort walking routes weighted by the PET. In the simulation, shortwave irradiance is calculated using the topographic radiation model (Fu and Rich, 1999) under various cloud cover scenarios; longwave irradiance is calculated based the radiative transfer equation (Swinbank, 1963). Combining these two factors, Tmrt (mean radiant temperature) is solved. And in some cases, the Tmrt differ more than 40 degree Celsius between areas under the sun and under the shades. Considering thermal load and wind information, we found that shading from buildings has stronger effect on PET than poor air ventilation resulted from dense buildings. We predict that pedestrians would feel more comfortable (lower PET) in a hot summer afternoon when walking in the higher building density area.

  3. Application of Markov chain model to daily maximum temperature for thermal comfort in Malaysia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nordin, Muhamad Asyraf bin Che; Hassan, Husna

    2015-10-22

    The Markov chain’s first order principle has been widely used to model various meteorological fields, for prediction purposes. In this study, a 14-year (2000-2013) data of daily maximum temperatures in Bayan Lepas were used. Earlier studies showed that the outdoor thermal comfort range based on physiologically equivalent temperature (PET) index in Malaysia is less than 34°C, thus the data obtained were classified into two state: normal state (within thermal comfort range) and hot state (above thermal comfort range). The long-run results show the probability of daily temperature exceed TCR will be only 2.2%. On the other hand, the probability dailymore » temperature within TCR will be 97.8%.« less

  4. Thermal sensation and climate: a comparison of UTCI and PET thresholds in different climates.

    PubMed

    Pantavou, Katerina; Lykoudis, Spyridon; Nikolopoulou, Marialena; Tsiros, Ioannis X

    2018-06-07

    The influence of physiological acclimatization and psychological adaptation on thermal perception is well documented and has revealed the importance of thermal experience and expectation in the evaluation of environmental stimuli. Seasonal patterns of thermal perception have been studied, and calibrated thermal indices' scales have been proposed to obtain meaningful interpretations of thermal sensation indices in different climate regions. The current work attempts to quantify the contribution of climate to the long-term thermal adaptation by examining the relationship between climate normal annual air temperature (1971-2000) and such climate-calibrated thermal indices' assessment scales. The thermal sensation ranges of two thermal indices, the Universal Thermal Climate Index (UTCI) and the Physiological Equivalent Temperature Index (PET), were calibrated for three warm temperate climate contexts (Cfa, Cfb, Csa), against the subjective evaluation of the thermal environment indicated by interviewees during field surveys conducted at seven European cities: Athens (GR), Thessaloniki (GR), Milan (IT), Fribourg (CH), Kassel (DE), Cambridge (UK), and Sheffield (UK), under the same research protocol. Then, calibrated scales for other climate contexts were added from the literature, and the relationship between the respective scales' thresholds and climate normal annual air temperature was examined. To maintain the maximum possible comparability, three methods were applied for the calibration, namely linear, ordinal, and probit regression. The results indicated that the calibrated UTCI and PET thresholds increase with the climate normal annual air temperature of the survey city. To investigate further climates, we also included in the analysis results of previous studies presenting only thresholds for neutral thermal sensation. The average increase of the respective thresholds in the case of neutral thermal sensation was about 0.6 °C for each 1 °C increase of the normal annual air temperature for both indices, statistically significant only for PET though.

  5. Thermal sensation prediction by soft computing methodology.

    PubMed

    Jović, Srđan; Arsić, Nebojša; Vilimonović, Jovana; Petković, Dalibor

    2016-12-01

    Thermal comfort in open urban areas is very factor based on environmental point of view. Therefore it is need to fulfill demands for suitable thermal comfort during urban planning and design. Thermal comfort can be modeled based on climatic parameters and other factors. The factors are variables and they are changed throughout the year and days. Therefore there is need to establish an algorithm for thermal comfort prediction according to the input variables. The prediction results could be used for planning of time of usage of urban areas. Since it is very nonlinear task, in this investigation was applied soft computing methodology in order to predict the thermal comfort. The main goal was to apply extreme leaning machine (ELM) for forecasting of physiological equivalent temperature (PET) values. Temperature, pressure, wind speed and irradiance were used as inputs. The prediction results are compared with some benchmark models. Based on the results ELM can be used effectively in forecasting of PET. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Thermal comfort in Quebec City, Canada: sensitivity analysis of the UTCI and other popular thermal comfort indices in a mid-latitude continental city.

    PubMed

    Provençal, Simon; Bergeron, Onil; Leduc, Richard; Barrette, Nathalie

    2016-04-01

    The newly developed Universal Thermal Climate Index (UTCI), along with the physiological equivalent temperature (PET), the humidex (HX) and the wind chill index (WC), was calculated in Quebec City, Canada, a city with a strong seasonal climatic variability, over a 1-year period. The objective of this study is twofold: evaluate the operational benefits of implementing the UTCI for a climate monitoring program of public comfort and health awareness as opposed to relying on traditional and simple indices, and determine whether thermal comfort monitoring specific to dense urban neighborhoods is necessary to adequately fulfill the goals of the program. In order to do so, an analysis is performed to evaluate each of these indices' sensitivity to the meteorological variables that regulate them in different environments. Overall, the UTCI was found to be slightly more sensitive to mean radiant temperature, moderately more sensitive to humidity and much more sensitive to wind speed than the PET. This dynamic changed slightly depending on the environment and the season. In hot weather, the PET was found to be more sensitive to mean radiant temperature and therefore reached high values that could potentially be hazardous more frequently than the UTCI and the HX. In turn, the UTCI's stronger sensitivity to wind speed makes it a superior index to identify potentially hazardous weather in winter compared to the PET and the WC. Adopting the UTCI broadly would be an improvement over the traditionally popular HX and WC indices. The urban environment produced favorable conditions to sustain heat stress conditions, where the indices reached high values more frequently there than in suburban locations, which advocates for weather monitoring specific to denser urban areas.

  7. Thermal comfort in Quebec City, Canada: sensitivity analysis of the UTCI and other popular thermal comfort indices in a mid-latitude continental city

    NASA Astrophysics Data System (ADS)

    Provençal, Simon; Bergeron, Onil; Leduc, Richard; Barrette, Nathalie

    2016-04-01

    The newly developed Universal Thermal Climate Index (UTCI), along with the physiological equivalent temperature (PET), the humidex (HX) and the wind chill index (WC), was calculated in Quebec City, Canada, a city with a strong seasonal climatic variability, over a 1-year period. The objective of this study is twofold: evaluate the operational benefits of implementing the UTCI for a climate monitoring program of public comfort and health awareness as opposed to relying on traditional and simple indices, and determine whether thermal comfort monitoring specific to dense urban neighborhoods is necessary to adequately fulfill the goals of the program. In order to do so, an analysis is performed to evaluate each of these indices' sensitivity to the meteorological variables that regulate them in different environments. Overall, the UTCI was found to be slightly more sensitive to mean radiant temperature, moderately more sensitive to humidity and much more sensitive to wind speed than the PET. This dynamic changed slightly depending on the environment and the season. In hot weather, the PET was found to be more sensitive to mean radiant temperature and therefore reached high values that could potentially be hazardous more frequently than the UTCI and the HX. In turn, the UTCI's stronger sensitivity to wind speed makes it a superior index to identify potentially hazardous weather in winter compared to the PET and the WC. Adopting the UTCI broadly would be an improvement over the traditionally popular HX and WC indices. The urban environment produced favorable conditions to sustain heat stress conditions, where the indices reached high values more frequently there than in suburban locations, which advocates for weather monitoring specific to denser urban areas.

  8. Validation of the mean radiant temperature simulated by the RayMan software in urban environments.

    PubMed

    Lee, Hyunjung; Mayer, Helmut

    2016-11-01

    The RayMan software is worldwide applied in investigations on different issues in human-biometeorology. However, only the simulated mean radiant temperature (T mrt ) has been validated so far in a few case studies. They are based on T mrt values, which were experimentally determined in urban environments by use of a globe thermometer or applying the six-directional method. This study analyses previous T mrt validations in a comparative manner. Their results are extended by a recent validation of T mrt in an urban micro-environment in Freiburg (southwest Germany), which can be regarded as relatively heterogeneous due to different shading intensities by tree crowns. In addition, a validation of the physiologically equivalent temperature (PET) simulated by RayMan is conducted for the first time. The validations are based on experimentally determined T mrt and PET values, which were calculated from measured meteorological variables in the daytime of a clear-sky summer day. In total, the validation results show that RayMan is capable of simulating T mrt satisfactorily under relatively homogeneous site conditions. However, the inaccuracy of simulated T mrt is increasing with lower sun elevation and growing heterogeneity of the simulation site. As T mrt represents the meteorological variable that mostly governs PET in the daytime of clear-sky summer days, the accuracy of simulated T mrt is mainly responsible for the accuracy of simulated PET. The T mrt validations result in some recommendations, which concern an update of physical principles applied in the RayMan software to simulate the short- and long-wave radiant flux densities, especially from vertical building walls and tree crowns.

  9. Basic analysis of climate and urban bioclimate of Dar es Salaam, Tanzania

    NASA Astrophysics Data System (ADS)

    Ndetto, Emmanuel L.; Matzarakis, Andreas

    2013-10-01

    Better understanding of urban microclimate and bioclimate of any city is imperative today when the world is constrained by both urbanisation and global climate change. Urbanisation generally triggers changes in land cover and hence influencing the urban local climate. Dar es Salaam city in Tanzania is one of the fast growing cities. Assessment of its urban climate and the human biometeorological conditions was done using the easily available synoptic meteorological data covering the period 2001-2011. In particular, the physiologically equivalent temperature (PET) was calculated using the RayMan software and results reveal that the afternoon period from December to February (DJF season) is relatively the most thermal stressful period to human beings in Dar es Salaam where PET values of above 35 °C were found. Additionally, the diurnal cycle of the individual meteorological elements that influence the PET index were analysed and found that air temperature of 30-35 °C dominate the afternoon period from 12:00 to 15:00 hours local standard time at about 60 % of occurrence. The current results, though considered as preliminary to the ongoing urban climate study in the city, provide an insight on how urban climate research is of significant importance in providing useful climatic information for ensuring quality of life and wellbeing of city dwellers.

  10. Thermal bioclimate in Strasbourg - the 2003 heat wave

    NASA Astrophysics Data System (ADS)

    Matzarakis, Andreas; de Rocco, Manuela; Najjar, Georges

    2009-10-01

    This case study highlights the implications of the 2003 heat wave for the city of Strasbourg, France. The urban centers of France and other European countries were particularly affected by the heat wave. In some urban areas, the mortality rate was 60% above the expected value (Institute de Veille Sanitaire, 2003). The 2003 heat wave demonstrated once again that populations in urban centers are much more affected by extreme meteorological events than people living in rural areas. The aim of this analysis is to explore differences in thermal comfort conditions of (a) the city center of Strasbourg, and (b) its hinterland. The differences in thermal conditions existing between rural and urban areas are quantified by using a bio-climatological index termed physiologically equivalent temperature (PET). This index is based on the human energy balance and builds a relevant index for the quantification of the thermal environment of humans. We calculate the PET for the years 2003 and 2004 to highlight the temporal changes in the severity of climate extremes. The spatial scope of this study is improved compared to previous works in the field through the inclusion of PET calculations for five different sites on a central place in Strasbourg (Place Kléber). The calculations are characterized by different sky view factors and are compared to the reference site, which is located in a rural area. In the rural hinterland (Entzheim), the analysis of PET indicates a strong cold thermal stress during the winter months but no significant stress in summer. In 2003, summer temperatures were sensed as warmer compared to other years, but did not reach the extreme temperatures that may cause severe heat stress. For both the rural and the urban study sites PET was higher in the summer of 2003 than in 2004, which reflects the inferior thermal conditions in the urban area during the heat wave in 2003. For the entire study period, urban and rural day-time PET reached similar maximal values. Strong differences in PET, however, were observed between the rural and urban areas at night-time. The study of PET for several study sites on a central place in the city (Place Kléber) of Strasbourg for the years 2003 and 2004 showed that the sites with a higher sky view factor present higher values than sites with a lower sky view factor. The comparison of these PET values (Place Kléber) to the results for the rural area showed that during the day and the night the rural city of Entzheim has the lowest PET. During the day, the site at Place Kléber, which is located under a tree, has the lowest PET. The comparison of PET for the years 2003 and 2004 shows that PET in 2003 was about 5 to 7 K higher.

  11. Initial performance evaluation of a preclinical PET scanner available as a clip-on assembly in a sequential PET/MRI system.

    PubMed

    Vrigneaud, Jean-Marc; McGrath, John; Courteau, Alan; Pegg, Rosie; Sanchez-Pastor Gomis, Alberto; Camacho, Angela; Martin, Gary; Schramm, Nils; Brunotte, François

    2018-05-15

    We evaluated the performance characteristics of a prototype preclinical PET scanner available as an easy clippable assembly that can dock to an MRI system. The single ring version of the PET system consists of 8 detectors, each of which comprises a 12 × 12 silicon photomultipliers (SiPMs) array coupled with a dual layer of offset scintillation crystals to measure depth of interaction. The crystal arrays have 29 × 29 (30 × 30 for the outer layer) 4 mm long LYSO crystals (6 mm for the outer layer). The ring diameter is 119.2 mm and the axial field of view is 50.4 mm. The NEMA NU-4-2008 protocol was followed for studying the PET performance. Temperature stability of SiPMs was also investigated. The peak system absolute sensitivity was 4.70% with an energy window of 250-750 keV. The spatial resolution was 1.28/1.88/1.85 mm FWHM (radial/tangential/axial) at a distance of 5 mm from the center. Peak noise equivalent counting rate (NECR) and scatter fraction for mouse phantom were 61.9 kcps at 14.9 MBq and 21.0%, respectively. The uniformity was 6.3% and the spill-over ratios in the images of the water- and air-filled chambers were 0.07 and 0.17, respectively. Recovery coefficients ranged from 0.13 to 0.96. Change in sensitivity as a function of ambient temperature was 0.3%/°C. These first results indicate excellent spatial resolution performance for use with animal studies. Moreover, the clippable assembly can be upgraded to accept a second ring of SiPMs modules, leading to improved sensitivity and axial coverage. © 2018 Institute of Physics and Engineering in Medicine.

  12. Thermal human biometeorological conditions and subjective thermal sensation in pedestrian streets in Chengdu, China

    NASA Astrophysics Data System (ADS)

    Zeng, YuLang; Dong, Liang

    2015-01-01

    The outdoor thermal environment of a public space is highly relevant to the thermal perception of individuals, thereby affecting the use of space. This study aims to connect thermal human biometeorological conditions and subjective thermal sensation in hot and humid regions and to find its influence on street use. We performed a thermal comfort survey at three locations in a pedestrian precinct of Chengdu, China. Meteorological measurements and questionnaire surveys were used to assess the thermal sensation of respondents. The number of people visiting the streets was counted. Meanwhile, mean radiant temperature ( T mrt) and the physiological equivalent temperature (PET) index were used to evaluate the thermal environment. Analytical results reveal that weather and street design drive the trend of diurnal micrometeorological conditions of the street. With the same geometry and orientation, a street with no trees had wider ranges of meteorological parameters and a longer period of discomfort. The neutral temperature in Chengdu (24.4 °C PET) is similar to that in Taiwan, demonstrating substantial human tolerance to hot conditions in hot and humid regions. Visitors' thermal sensation votes showed the strongest positive relationships with air temperature. Overall comfort level was strongly related to every corresponding meteorological parameter, indicating the complexity of people's comfort in outdoor environments. In major alleys with multiple functions, the number of people in the street decreased as thermal indices increased; T mrt and PET had significant negative correlations with the number of people. This study aids in understanding pedestrian street use in hot and humid regions.

  13. (18)F-Fluorodeoxyglucose PET/MR Imaging in Head and Neck Cancer.

    PubMed

    Platzek, Ivan

    2016-10-01

    (18)F-fluorodeoxyglucose (FDG) PET/MR imaging does not offer significant additional information in initial staging of squamous cell carcinoma of the head and neck when compared with standalone MR imaging. In patients with suspected tumor recurrence, FDG PET/MR imaging has higher sensitivity than MR imaging, although its accuracy is equivalent to the accuracy of FDG PET/CT. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT.

    PubMed

    Yamashita, Shozo; Yokoyama, Kunihiko; Onoguchi, Masahisa; Yamamoto, Haruki; Hiko, Shigeaki; Horita, Akihiro; Nakajima, Kenichi

    2014-01-01

    Deep-inspiration breath-hold (DIBH) PET/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used.

  15. A comparative analysis of human thermal conditions in outdoor urban spaces in the summer season in Singapore and Changsha, China.

    PubMed

    Yang, Wei; Wong, Nyuk Hien; Zhang, Guoqiang

    2013-11-01

    This paper presents the comparative analysis between the findings from two field surveys of human thermal conditions in outdoor urban spaces during the summer season. The first survey was carried out from August 2010 to May 2011 in Singapore and the second survey was carried out from June 2010 to August 2010 in Changsha, China. The physiologically equivalent temperature (PET) was utilized as the thermal index to assess the thermal conditions. Differences were found between the two city respondents in terms of thermal sensation, humidity sensation, and wind speed sensation. No big difference was found between the two city respondents regarding the sun sensation. The two city respondents had similar neutral PET of 28.1 °C for Singapore and 27.9 °C for Changsha, respectively. However, Singapore respondents were more sensitive to PET change than Changsha respondents and the acceptable PET range for Changsha respondents was wider than that for Singapore respondents. Besides, the two city respondents had different thermal expectations with the preferred PET of 25.2 °C and 22.1 °C for Singapore and Changsha, respectively. The results also reveal that Changsha respondents were more tolerant than Singapore respondents under hot conditions. Finally, two regression models were proposed for Singapore and Changsha to predict the human thermal sensation in a given outdoor thermal environment.

  16. Residual stress analysis for oxide thin film deposition on flexible substrate using finite element method

    NASA Astrophysics Data System (ADS)

    Chen, Hsi-Chao; Huang, Chen-Yu; Lin, Ssu-Fan; Chen, Sheng-Hui

    2011-09-01

    Residual or internal stresses directly affect a variety of phenomena including adhesion, generation of crystalline defects, perfection of epitaxial layers and formation of film surface growths such as hillocks and whiskers. Sputtering oxide films with high density promote high compressive stress, and it offers researchers a reference if the value of residual stress could be analyzed directly. Since, the study of residual stress of SiO2 and Nb2O5 thin film deposited by DC magnetron sputtered on hard substrate (BK7) and flexible substrate (PET and PC). A finite element method (FEM) with an equivalent-reference-temperature (ERT) technique had been proposed and used to model and evaluate the intrinsic strains of layered structures. The research has improved the equivalent reference temperature (ERT) technique of the simulation of intrinsic strain for oxygen film. The results have also generalized two models connecting to the lattice volume to predict the residual stress of hard substrate and flexible substrate with error of 3% and 6%, respectively.

  17. A Prospective, Matched Comparison Study of SUV Measurements From Time-of-Flight Versus Non-Time-of-Flight PET/CT Scanners.

    PubMed

    Thompson, Holly M; Minamimoto, Ryogo; Jamali, Mehran; Barkhodari, Amir; von Eyben, Rie; Iagaru, Andrei

    2016-07-01

    As quantitative F-FDG PET numbers and pooling of results from different PET/CT scanners become more influential in the management of patients, it becomes imperative that we fully interrogate differences between scanners to fully understand the degree of scanner bias on the statistical power of studies. Participants with body mass index (BMI) greater than 25, scheduled on a time-of-flight (TOF)-capable PET/CT scanner, had a consecutive scan on a non-TOF-capable PET/CT scanner and vice versa. SUVmean in various tissues and SUVmax of malignant lesions were measured from both scans, matched to each subject. Data were analyzed using a mixed-effects model, and statistical significance was determined using equivalence testing, with P < 0.05 being significant. Equivalence was established in all baseline organs, except the cerebellum, matched per patient between scanner types. Mixed-effects method analysis of lesions, repeated between scan types and matched per patient, demonstrated good concordance between scanner types. Patients could be scanned on either a TOF or non-TOF-capable PET/CT scanner without clinical compromise to quantitative SUV measurements.

  18. Assessing spatial associations between thermal stress and mortality in Hong Kong: a small-area ecological study.

    PubMed

    Thach, Thuan-Quoc; Zheng, Qishi; Lai, Poh-Chin; Wong, Paulina Pui-Yun; Chau, Patsy Yuen-Kwan; Jahn, Heiko J; Plass, Dietrich; Katzschner, Lutz; Kraemer, Alexander; Wong, Chit-Ming

    2015-01-01

    Physiological equivalent temperature (PET) is a widely used index to assess thermal comfort of the human body. Evidence on how thermal stress-related health effects vary with small geographical areas is limited. The objectives of this study are (i) to explore whether there were significant patterns of geographical clustering of thermal stress as measured by PET and mortality and (ii) to assess the association between PET and mortality in small geographical areas. A small area ecological cross-sectional study was conducted at tertiary planning units (TPUs) level. Age-standardized mortality rates (ASMR) and monthly deaths at TPUs level for 2006 were calculated for cause-specific diseases. A PET map with 100 m × 100 m resolution for the same period was derived from Hong Kong Urban Climatic Analysis Map data and the annual and monthly averages of PET for each TPU were computed. Global Moran's I and local indicator of spatial association (LISA) analyses were performed. A generalized linear mixed model was used to model monthly deaths against PET adjusted for socio-economic deprivation. We found positive spatial autocorrelation between PET and ASMR. There were spatial correlations between PET and ASMR, particularly in the north of Hong Kong Island, most parts of Kowloon, and across New Territories. A 1°C change in PET was associated with an excess risk (%) of 2.99 (95% CI: 0.50-5.48) for all natural causes, 4.75 (1.14-8.36) for cardiovascular, 7.39 (4.64-10.10) for respiratory diseases in the cool season, and 4.31 (0.12 to 8.50) for cardiovascular diseases in the warm season. Variations between TPUs in PET had an important influence on cause-specific mortality, especially in the cool season. PET may have an impact on the health of socio-economically deprived population groups. Our results suggest that targeting policy interventions at high-risk areas may be a feasible option for reducing PET-related mortality. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Thermal comfort of pedestrians in an urban street canyon is affected by increasing albedo of building walls

    NASA Astrophysics Data System (ADS)

    Lee, Hyunjung; Mayer, Helmut

    2018-03-01

    Numerical simulations based on the ENVI-met model were carried out for an E-W street canyon in the city of Stuttgart (Southwest Germany) to analyse the effect of increased albedo of building walls on outdoor human thermal comfort. It was quantified by air temperature (T a ), mean radiant temperature (T mrt ) and physiologically equivalent temperature (PET). The simulations were conducted on 4 August 2003 as a heat wave day that represents a typical scenario for future summer weather in Central Europe. The simulation results presented for 13 CET and averaged over the period 10-16 CET are focused on pedestrians on both sidewalks. For the initial situation, i.e. albedo of 0.2, human heat stress indicated by mean PET is by 26% lower on the N-facing than on the S-facing sidewalk, while this reduction amounts to 42% for mean T mrt . Mean T a does not show any spatial differentiation. The systematic albedo increment by 0.2 from 0.2 to 0.8 leads to a linear increase of outdoor human heat stress in terms of T mrt and PET. For both variables, this increase is more pronounced on the N-facing than on the S-facing sidewalk. Mean relative T a shows the tendency of a minimal increase with rising albedo. The results were achieved for the usual standardised human-biometeorological reference person. Its substitution by two other types of male and female pedestrians, respectively, which are statistically characteristic of human conditions in Germany, does not reveal any significant change in the results.

  20. Thermal comfort of pedestrians in an urban street canyon is affected by increasing albedo of building walls.

    PubMed

    Lee, Hyunjung; Mayer, Helmut

    2018-03-12

    Numerical simulations based on the ENVI-met model were carried out for an E-W street canyon in the city of Stuttgart (Southwest Germany) to analyse the effect of increased albedo of building walls on outdoor human thermal comfort. It was quantified by air temperature (T a ), mean radiant temperature (T mrt ) and physiologically equivalent temperature (PET). The simulations were conducted on 4 August 2003 as a heat wave day that represents a typical scenario for future summer weather in Central Europe. The simulation results presented for 13 CET and averaged over the period 10-16 CET are focused on pedestrians on both sidewalks. For the initial situation, i.e. albedo of 0.2, human heat stress indicated by mean PET is by 26% lower on the N-facing than on the S-facing sidewalk, while this reduction amounts to 42% for mean T mrt . Mean T a does not show any spatial differentiation. The systematic albedo increment by 0.2 from 0.2 to 0.8 leads to a linear increase of outdoor human heat stress in terms of T mrt and PET. For both variables, this increase is more pronounced on the N-facing than on the S-facing sidewalk. Mean relative T a shows the tendency of a minimal increase with rising albedo. The results were achieved for the usual standardised human-biometeorological reference person. Its substitution by two other types of male and female pedestrians, respectively, which are statistically characteristic of human conditions in Germany, does not reveal any significant change in the results.

  1. Evaluation of the tourism climate in the Hexi Corridor of northwest China's Gansu Province during 1980-2012

    NASA Astrophysics Data System (ADS)

    Zhang, Fuxian; Zhang, Mingjun; Wang, Shengjie; Qiang, Fang; Che, Yanjun; Wang, Jie

    2017-08-01

    As a pivotal section of the Silk Road in northwest China, the Hexi Corridor is a popular tourist destination. In this study, the tourism climate conditions in this region were discussed using the Physiologically Equivalent Temperature (PET) and the Climate-Tourism/Transfer-information-Scheme (CTIS) from 1980 to 2012. Overall, cold or cool stress was prevalent in the area, and the optimal travel period was from May to September. With global warming, the annual numbers of cumulative days with relatively cold conditions decreased, and the annual numbers of cumulative days with comfortable and relatively hot conditions increased. Two typical stations, Wushaoling and Dunhuang, were compared and analysed for their tourism climate information according to the frequency of PET and CTIS conditions, respectively. In addition, regional variations in the tourism climate conditions based on geographic information systems (GIS) were investigated during the optimal travel period.

  2. Hybrid FDG-PET/MR compared to FDG-PET/CT in adult lymphoma patients.

    PubMed

    Atkinson, Wendy; Catana, Ciprian; Abramson, Jeremy S; Arabasz, Grae; McDermott, Shanaugh; Catalano, Onofrio; Muse, Victorine; Blake, Michael A; Barnes, Jeffrey; Shelly, Martin; Hochberg, Ephraim; Rosen, Bruce R; Guimaraes, Alexander R

    2016-07-01

    The goal of this study is to evaluate the diagnostic performance of simultaneous FDG-PET/MR including diffusion compared to FDG-PET/CT in patients with lymphoma. Eighteen patients with a confirmed diagnosis of non-Hodgkin's (NHL) or Hodgkin's lymphoma (HL) underwent an IRB-approved, single-injection/dual-imaging protocol consisting of a clinical FDG-PET/CT and subsequent FDG-PET/MR scan. PET images from both modalities were reconstructed iteratively. Attenuation correction was performed using low-dose CT data for PET/CT and Dixon-MR sequences for PET/MR. Diffusion-weighted imaging was performed. SUVmax was measured and compared between modalities and the apparent diffusion coefficient (ADC) using ROI analysis by an experienced radiologist using OsiriX. Strength of correlation between variables was measured using the Pearson correlation coefficient (r p). Of the 18 patients included in this study, 5 had HL and 13 had NHL. The median age was 51 ± 14.8 years. Sixty-five FDG-avid lesions were identified. All FDG-avid lesions were visible with comparable contrast, and therefore initial and follow-up staging was identical between both examinations. SUVmax from FDG-PET/MR [(mean ± sem) (21.3 ± 2.07)] vs. FDG-PET/CT (mean 23.2 ± 2.8) demonstrated a strongly positive correlation [r s = 0.95 (0.94, 0.99); p < 0.0001]. There was no correlation found between ADCmin and SUVmax from FDG-PET/MR [r = 0.17(-0.07, 0.66); p = 0.09]. FDG-PET/MR offers an equivalent whole-body staging examination as compared with PET/CT with an improved radiation safety profile in lymphoma patients. Correlation of ADC to SUVmax was weak, understating their lack of equivalence, but not undermining their potential synergy and differing importance.

  3. 10 CFR 35.63 - Determination of dosages of unsealed byproduct material for medical use.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or equivalent Agreement... State requirements; or (ii) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or...

  4. 10 CFR 35.63 - Determination of dosages of unsealed byproduct material for medical use.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or equivalent Agreement... State requirements; or (ii) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or...

  5. 10 CFR 35.63 - Determination of dosages of unsealed byproduct material for medical use.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or equivalent Agreement... State requirements; or (ii) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or...

  6. 10 CFR 35.63 - Determination of dosages of unsealed byproduct material for medical use.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or equivalent Agreement... State requirements; or (ii) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or...

  7. 10 CFR 35.63 - Determination of dosages of unsealed byproduct material for medical use.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or equivalent Agreement... State requirements; or (ii) A PET radioactive drug producer licensed under § 30.32(j) of this chapter or...

  8. Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions

    NASA Astrophysics Data System (ADS)

    Kolthammer, Jeffrey A.; Su, Kuan-Hao; Grover, Anu; Narayanan, Manoj; Jordan, David W.; Muzic, Raymond F.

    2014-07-01

    This study evaluated the positron emission tomography (PET) imaging performance of the Ingenuity TF 128 PET/computed tomography (CT) scanner which has a PET component that was designed to support a wider radioactivity range than is possible with those of Gemini TF PET/CT and Ingenuity TF PET/MR. Spatial resolution, sensitivity, count rate characteristics and image quality were evaluated according to the NEMA NU 2-2007 standard and ACR phantom accreditation procedures; these were supplemented by additional measurements intended to characterize the system under conditions that would be encountered during quantitative cardiac imaging with 82Rb. Image quality was evaluated using a hot spheres phantom, and various contrast recovery and noise measurements were made from replicated images. Timing and energy resolution, dead time, and the linearity of the image activity concentration, were all measured over a wide range of count rates. Spatial resolution (4.8-5.1 mm FWHM), sensitivity (7.3 cps kBq-1), peak noise-equivalent count rate (124 kcps), and peak trues rate (365 kcps) were similar to those of the Gemini TF PET/CT. Contrast recovery was higher with a 2 mm, body-detail reconstruction than with a 4 mm, body reconstruction, although the precision was reduced. The noise equivalent count rate peak was broad (within 10% of peak from 241-609 MBq). The activity measured in phantom images was within 10% of the true activity for count rates up to those observed in 82Rb cardiac PET studies.

  9. NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system.

    PubMed

    Grant, Alexander M; Deller, Timothy W; Khalighi, Mohammad Mehdi; Maramraju, Sri Harsha; Delso, Gaspar; Levin, Craig S

    2016-05-01

    The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

  10. PET/MRI in Oncological Imaging: State of the Art

    PubMed Central

    Bashir, Usman; Mallia, Andrew; Stirling, James; Joemon, John; MacKewn, Jane; Charles-Edwards, Geoff; Goh, Vicky; Cook, Gary J.

    2015-01-01

    Positron emission tomography (PET) combined with magnetic resonance imaging (MRI) is a hybrid technology which has recently gained interest as a potential cancer imaging tool. Compared with CT, MRI is advantageous due to its lack of ionizing radiation, superior soft-tissue contrast resolution, and wider range of acquisition sequences. Several studies have shown PET/MRI to be equivalent to PET/CT in most oncological applications, possibly superior in certain body parts, e.g., head and neck, pelvis, and in certain situations, e.g., cancer recurrence. This review will update the readers on recent advances in PET/MRI technology and review key literature, while highlighting the strengths and weaknesses of PET/MRI in cancer imaging. PMID:26854157

  11. The relationship between bioclimatic thermal stress and subjective thermal sensation in pedestrian spaces

    NASA Astrophysics Data System (ADS)

    Pearlmutter, David; Jiao, Dixin; Garb, Yaakov

    2014-12-01

    Outdoor thermal comfort has important implications for urban planning and energy consumption in the built environment. To better understand the relation of subjective thermal experience to bioclimatic thermal stress in such contexts, this study compares micrometeorological and perceptual data from urban spaces in the hot-arid Negev region of Israel. Pedestrians reported on their thermal sensation in these spaces, whereas radiation and convection-related data were used to compute the Index of Thermal Stress (ITS) and physiologically equivalent temperature (PET). The former is a straightforward characterization of energy exchanges between the human body and its surroundings, without any conversion to an "equivalent temperature." Although the relation of ITS to subjective thermal sensation has been analyzed in the past under controlled indoor conditions, this paper offers the first analysis of this relation in an outdoor setting. ITS alone can account for nearly 60 % of the variance in pedestrians' thermal sensation under outdoor conditions, somewhat more than PET. A series of regressions with individual contextual variables and ITS identified those factors which accounted for additional variance in thermal sensation, whereas multivariate analyses indicated the considerable predictive power ( R-square = 0.74) of models including multiple contextual variables in addition to ITS. Our findings indicate that pedestrians experiencing variable outdoor conditions have a greater tolerance for incremental changes in thermal stress than has been shown previously under controlled indoor conditions, with a tapering of responses at high values of ITS. However, the thresholds of ITS corresponding to thermal "neutrality" and thermal "acceptability" are quite consistent regardless of context.

  12. The relationship between bioclimatic thermal stress and subjective thermal sensation in pedestrian spaces.

    PubMed

    Pearlmutter, David; Jiao, Dixin; Garb, Yaakov

    2014-12-01

    Outdoor thermal comfort has important implications for urban planning and energy consumption in the built environment. To better understand the relation of subjective thermal experience to bioclimatic thermal stress in such contexts, this study compares micrometeorological and perceptual data from urban spaces in the hot-arid Negev region of Israel. Pedestrians reported on their thermal sensation in these spaces, whereas radiation and convection-related data were used to compute the Index of Thermal Stress (ITS) and physiologically equivalent temperature (PET). The former is a straightforward characterization of energy exchanges between the human body and its surroundings, without any conversion to an "equivalent temperature." Although the relation of ITS to subjective thermal sensation has been analyzed in the past under controlled indoor conditions, this paper offers the first analysis of this relation in an outdoor setting. ITS alone can account for nearly 60 % of the variance in pedestrians' thermal sensation under outdoor conditions, somewhat more than PET. A series of regressions with individual contextual variables and ITS identified those factors which accounted for additional variance in thermal sensation, whereas multivariate analyses indicated the considerable predictive power (R-square = 0.74) of models including multiple contextual variables in addition to ITS. Our findings indicate that pedestrians experiencing variable outdoor conditions have a greater tolerance for incremental changes in thermal stress than has been shown previously under controlled indoor conditions, with a tapering of responses at high values of ITS. However, the thresholds of ITS corresponding to thermal "neutrality" and thermal "acceptability" are quite consistent regardless of context.

  13. Evaluation of thermal perception in schoolyards under Mediterranean climate conditions

    NASA Astrophysics Data System (ADS)

    Antoniadis, D.; Katsoulas, N.; Papanastasiou, D.; Christidou, V.; Kittas, C.

    2016-03-01

    The aim of this paper was to study qualitatively and quantitatively the thermal perception and corresponding heat stress conditions that prevail in two schoolyards in a coastal city in central Greece. For this purpose, meteorological parameters (i.e., wind speed, temperature, relative humidity, solar radiation) were recorded at 70 and 55 measuring points in the schoolyards, from 14:00 to 15:30 local time, during May and June of 2011. The measuring points were distributed so as to get measurements at points (a) directly exposed to the sun, (b) under the shadow of trees and building structures, and (c) near building structures. Cluster analysis was applied to group observations and revealed places that are microclimatically homogeneous. Thermal perception and heat stress conditions were assessed by means of the physiologically equivalent temperature (PET, °C), and the results are presented in relevant charts. The impact of material's albedo, radiation's reflection by structures and obstacles, and different tree species on thermal perception and heat stress conditions was also assessed. The analysis showed that trees triggered a reduction of incident solar radiation that ranged between 79 and 94 % depending on tree's species, crown dimension, tree height, and leaf area. PET values were mainly affected by solar radiation and wind speed. Trees caused a reduction of up to 37 % in PET values, while a 1-m s-1 increase in wind speed triggered a reduction of 3.7-5.0 °C in PET value. The effective shading area in the two schoolyards was small, being 27.5 and 11 %. The results of this study could be exploited by urban planning managers when designing or improving the outdoor environment of a school complex.

  14. Adjustment of the thermal component of two tourism climatological assessment tools using thermal perception and preference surveys from Hungary

    NASA Astrophysics Data System (ADS)

    Kovács, Attila; Unger, János; Gál, Csilla V.; Kántor, Noémi

    2016-07-01

    This study introduces new methodological concepts for integrating seasonal subjective thermal assessment patterns of people into the thermal components of two tourism climatological evaluation tools: the Tourism Climatic Index (TCI) and the Climate-Tourism/Transfer-Information-Scheme (CTIS). In the case of the TCI, we replaced the air temperature and relative humidity as the basis of the initial rating system with the physiologically equivalent temperature (PET)—a complex human biometeorological index. This modification improves the TCI's potential to evaluate the thermal aspects of climate. The major accomplishments of this study are (a) the development of a new, PET-based rating system and its integration into the thermal sub-indices of the TCI and (b) the regionalization of the thermal components of CTIS to reflect both the thermal sensation and preference patterns of people. A 2-year-long (2011-2012) thermal comfort survey conducted in Szeged, Hungary, from spring to autumn was utilized to demonstrate the implementation of the introduced concepts. We found considerable differences between the thermal perception and preference patterns of Hungarians, with additional variations across the evaluated seasons. This paper describes the proposed methodology for the integration of the new seasonal, perception-based, and preference-based PET rating systems into the TCI, and presents the incorporation of new PET thresholds into the CTIS. In order to demonstrate the utility of the modified evaluation tools, we performed case study climate analyses for three Hungarian tourist destinations. The additional adjustments introduced during the course of those analyses include the reduction of TCI's temporal resolution to 10-day intervals and the exclusion of nocturnal and winter periods from the investigation.

  15. Initial performance evaluation of a preclinical PET scanner available as a clip-on assembly in a sequential PET/MRI system

    NASA Astrophysics Data System (ADS)

    Vrigneaud, J. M.; McGrath, J.; Courteau, A.; Pegg, R.; Sanchez-Pastor Gomis, A.; Camacho, A.; Martin, G.; Schramm, N.; Brunotte, F.

    2018-06-01

    We evaluated the performance characteristics of a prototype preclinical PET scanner available as an easy clippable assembly that can dock to an MRI system. The single ring version of the PET system consists of eight detectors, each of which comprises a 12  ×  12 silicon photomultipliers (SiPMs) array coupled with a dual layer of offset scintillation crystals to measure depth of interaction. The crystal arrays have 29  ×  29 (30  ×  30 for the outer layer) 4 mm long LYSO crystals (6 mm for the outer layer). The ring diameter is 119.2 mm and the axial field of view is 50.4 mm. The NEMA NU 4-2008 protocol was followed for studying the PET performance. Temperature stability of SiPMs was also investigated. The peak system absolute sensitivity was 4.70% with an energy window of 250–750 keV. The spatial resolution was 1.28/1.88/1.85 mm FWHM (radial/tangential/axial) at a distance of 5 mm from the center. Peak noise equivalent counting rate and scatter fraction for mouse phantom were 61.9 kcps at 14.9 MBq and 21.0%, respectively. The uniformity was 6.3% and the spill-over ratios in the images of the water-and air-filled chambers were 0.07 and 0.17, respectively. Recovery coefficients ranged from 0.13 to 0.96. Change in sensitivity as a function of ambient temperature was 0.3%/°C. These first results indicate excellent spatial resolution performance for use with animal studies. Moreover, the clippable assembly can be upgraded to accept a second ring of SiPMs modules, leading to improved sensitivity and axial coverage.

  16. Effect of household pet ownership on infant immune response and subsequent sensitization

    PubMed Central

    Simpson, Angela

    2010-01-01

    Sensitization to pets is a major risk factor for asthma. There are many reports on the relationship between household pets, sensitization to the pet, and sensitization to other allergens, often with conflicting results. Pet ownership is not random, and household pets are associated with exposures other than pet allergens. We will review some of the evidence regarding the effects of household pets on infant immune responses, focusing on data from birth cohort studies. It remains unclear precisely why some children develop specific sensitizations to pets whilst others do not in the face of equivalent exposures, but it is likely to be due to gene-environment interactions. Further long-term follow-up of children in whom neonatal and infant immune responses have been measured is necessary to understand how these events occur and how they relate to subsequent disease. PMID:21437047

  17. Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT

    PubMed Central

    Queiroz, Marcelo A.; Delso, Gaspar; Wollenweber, Scott; Deller, Timothy; Zeimpekis, Konstantinos; Huellner, Martin; de Galiza Barbosa, Felipe; von Schulthess, Gustav; Veit-Haibach, Patrick

    2015-01-01

    Purpose To evaluate the possible activity reduction in FDG-imaging in a Time-of-Flight (TOF) PET/MR, based on cross-evaluation of patient-based NECR (noise equivalent count rate) measurements in PET/CT, cross referencing with phantom-based NECR curves as well as initial evaluation of TOF-PET/MR with reduced activity. Materials and Methods A total of 75 consecutive patients were evaluated in this study. PET/CT imaging was performed on a PET/CT (time-of-flight (TOF) Discovery D 690 PET/CT). Initial PET/MR imaging was performed on a newly available simultaneous TOF-PET/MR (Signa PET/MR). An optimal NECR for diagnostic purposes was defined in clinical patients (NECRP) in PET/CT. Subsequent optimal activity concentration at the acquisition time ([A]0) and target NECR (NECRT) were obtained. These data were used to predict the theoretical FDG activity requirement of the new TOF-PET/MR system. Twenty-five initial patients were acquired with (retrospectively reconstructed) different imaging times equivalent for different activities on the simultaneous PET/MR for the evaluation of clinically realistic FDG-activities. Results The obtained values for NECRP, [A]0 and NECRT were 114.6 (± 14.2) kcps (Kilocounts per second), 4.0 (± 0.7) kBq/mL and 45 kcps, respectively. Evaluating the NECRT together with the phantom curve of the TOF-PET/MR device, the theoretical optimal activity concentration was found to be approximately 1.3 kBq/mL, which represents 35% of the activity concentration required by the TOF-PET/CT. Initial evaluation on patients in the simultaneous TOF-PET/MR shows clinically realistic activities of 1.8 kBq/mL, which represent 44% of the required activity. Conclusion The new TOF-PET/MR device requires significantly less activity to generate PET-images with good-to-excellent image quality, due to improvements in detector geometry and detector technologies. The theoretically achievable dose reduction accounts for up to 65% but cannot be fully translated into clinical routine based on the coils within the FOV and MR-sequences applied at the same time. The clinically realistic reduction in activity is slightly more than 50%. Further studies in a larger number of patients are needed to confirm our findings. PMID:26147919

  18. Human biometeorological analysis of the thermal conditions of the hot Turkish city of Şanliurfa

    NASA Astrophysics Data System (ADS)

    Toy, Süleyman; Aytaç, Ahmet Serdar; Kántor, Noémi

    2018-01-01

    This paper offers a throughout human biometeorological assessment about the thermal conditions of Şanliurfa in one of the hottest parts of Turkey, in the hottest period of the year (from April to October), and a comparative analysis of three built-up types (urban, suburban and rural). Therefore, the values of physiologically equivalent temperature (PET), one of the most extensively used indices, were calculated from basic climate data with the help of the RayMan model. It was found by regarding the resulted mean PET values and the occurrence frequency of extreme heat stress periods (PET values above 41 °C) that the urban area exhibited the most unfavourable properties, followed by the suburban and rural areas. We also found very severe heat stress conditions in the summer, which may be explained by the torrid and arid climate, calm air conditions and the lack of abundant vegetation. Aiming to optimise human thermal conditions, thereby improving local life quality and facilitating international tourism, increment of vegetated areas and water surfaces would be required and, of course, highlighting the traditional methods taking into account the important aspects of sustainability.

  19. Comparison of different methods for the assessment of the urban heat island in Stuttgart, Germany.

    PubMed

    Ketterer, Christine; Matzarakis, Andreas

    2015-09-01

    This study of the urban heat island (UHI) aims to support planning authorities by going beyond the traditional way of urban heat island studies. Therefore, air temperature as well as the physiologically equivalent temperature (PET) were applied to take into account the effect of the thermal atmosphere on city dwellers. The analysis of the urban heat island phenomenon of Stuttgart, Germany, includes a long-term frequency analysis using data of four urban and one rural meteorological stations. A (high resolution map) of the UHI intensity and PET was created using stepwise multiple linear regression based on data of car traverses as well as spatial data. The mapped conditions were classified according to the long-term frequency analysis. Regarding climate change, the need for adaptation measures as urban greening is obvious. Therefore, a spatial analysis of quantification of two scenarios of a chosen study area was done by the application of a micro-scale model. The nocturnal UHI of Stuttgart is during 15 % stronger than 4 K in the city center during summer when daytime heat stress occurs during 40 %. A typical summer condition is mapped using statistical approach to point out the most strained areas in Stuttgart center and west. According to the model results, the increase in number of trees in a chosen area (Olga hospital) can decrease PET by 0.5 K at 22:00 CET but by maximum 27 K at 14:00 CET.

  20. Modeling and in situ measurements of biometeorological conditions in microenvironments within the Athens University Campus, Greece

    NASA Astrophysics Data System (ADS)

    Nastos, Panagiotis T.; Polychroni, Iliana D.

    2016-10-01

    The objective of this research is to assess and analyze the biometeorological perception in complex microenvironments in the Athens University Campus (AUC) using urban micromodels, such as RayMan. The human thermal sensation in such a place was considered of great significance due to the great gathering of student body and staff of the University. The quantification of the biometeorological conditions was succeeded by the estimation of the physiologically equivalent temperature (PET), which is a biometeorological index based on the human energy balance. We carried out, on one hand, field measurements of air temperature, relative humidity, wind speed, and global solar irradiance for different sites (building atrium, open area, and green atrium) of the examined microurban environment in order to calculate PET during January-July 2013. Additionally, on the other hand, PET modeling was performed using different sky-view factors and was compared to a reference site (meteorological station of Laboratory of Climatology and Atmospheric Environment, University of Athens). The global radiation was transferred to the examined sites with the RayMan model, which considers the sky-view factors for the adaptation of the radiation fluxes to simple and complex environments. The results of this study reveal the crucial importance of the existence of trees and green cover in a complex environment, as a factor that could be the solution to the efforts of stake holders in order to mitigate strong heat stress and improve people's living quality in urban areas.

  1. Modeling and in situ measurements of biometeorological conditions in microenvironments within the Athens University Campus, Greece.

    PubMed

    Nastos, Panagiotis T; Polychroni, Iliana D

    2016-10-01

    The objective of this research is to assess and analyze the biometeorological perception in complex microenvironments in the Athens University Campus (AUC) using urban micromodels, such as RayMan. The human thermal sensation in such a place was considered of great significance due to the great gathering of student body and staff of the University. The quantification of the biometeorological conditions was succeeded by the estimation of the physiologically equivalent temperature (PET), which is a biometeorological index based on the human energy balance. We carried out, on one hand, field measurements of air temperature, relative humidity, wind speed, and global solar irradiance for different sites (building atrium, open area, and green atrium) of the examined microurban environment in order to calculate PET during January-July 2013. Additionally, on the other hand, PET modeling was performed using different sky-view factors and was compared to a reference site (meteorological station of Laboratory of Climatology and Atmospheric Environment, University of Athens). The global radiation was transferred to the examined sites with the RayMan model, which considers the sky-view factors for the adaptation of the radiation fluxes to simple and complex environments. The results of this study reveal the crucial importance of the existence of trees and green cover in a complex environment, as a factor that could be the solution to the efforts of stake holders in order to mitigate strong heat stress and improve people's living quality in urban areas.

  2. Evaluating the behaviour of different thermal indices by investigating various outdoor urban environments in the hot dry city of Damascus, Syria

    NASA Astrophysics Data System (ADS)

    Yahia, Moohammed Wasim; Johansson, Erik

    2013-07-01

    Consideration of urban microclimate and thermal comfort is an absolute neccessity in urban development, and a set of guidelines for every type of climate must be elaborated. However, to develop guidelines, thermal comfort ranges need to be defined. The aim of this study was to evaluate the behaviour of different thermal indices by investigating different thermal environments in Damascus during summer and winter. A second aim was to define the lower and upper limits of the thermal comfort range for some of these indices. The study was based on comprehensive micrometeorological measurements combined with questionnaires. It was found that the thermal conditions of different outdoor environments vary considerably. In general, Old Damascus, with its deep canyons, is more comfortable in summer than modern Damascus where there is a lack of shade. Conversely, residential areas and parks in modern Damascus are more comfortable in winter due to more solar access. The neutral temperatures of both the physiologically equivalent temperature (PET) and the outdoor standard effective temperature (OUT_SET*) were found to be lower in summer than in winter. At 80 % acceptability, the study defined the lower comfort limit in winter to 21.0 °C and the upper limit in summer to 31.3 °C for PET. For OUT_SET*, the corresponding lower and upper limits were 27.6 °C and 31.3 °C respectively. OUT_SET* showed a better correlation with the thermal sensation votes than PET. The study also highlighted the influence of culture and traditions on people's clothing as well as the influence of air conditioning on physical adaptation.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grant, Alexander M.; Deller, Timothy W.; Maramraju, Sri Harsha

    Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: Themore » NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.« less

  4. Performance evaluation of a LYSO-based PET scanner for monitoring of dose delivery in hadrontherapy

    NASA Astrophysics Data System (ADS)

    Fabbiani, E.; Belcari, N.; Camarlinghi, N.; Del Guerra, A.; Ferretti, S.; Kraan, A.; Panetta, D.; Sportelli, G.; Rosso, V.

    2015-12-01

    The DoPET scanner is a compact positron emission tomography (PET) device. It has been developed for monitoring the range of charged particles during therapy with hadron beams. Previous works have focused on the development and upgrade of the device and on data analysis. In this paper, a full performance characterization of the DoPET system in terms of the energy resolution, spatial resolution, sensitivity, uniformity, and noise equivalent count rate is reported. All measurements refer to an adapted version of the National Electrical Manufacturers Association (NEMA) NU 4 - 2008 protocol, which was written originally for small animal PET systems. Since DoPET is a dual head planar system, it requires a modified characterisation procedure with respect to those described for ring geometries as in the NEMA NU 4 - 2008 protocol. The presented procedure may be of interest for any other PET system with a similar geometry as DoPET.

  5. Influence of Elevated Temperatures on Pet-Concrete Properties

    NASA Astrophysics Data System (ADS)

    Albano, C.; Camacho, N.; Hernández, M.; Matheus, A.; Gutiérrez, A.

    2008-08-01

    Lightweight aggregate is an important material in reducing the unit weight of concrete complying with special concrete structures of large high-rise buildings. Besides, the use of recycled PET bottles as lightweight aggregate in concrete is an effective contribution for environment preservation. So, the objective of the present work was to study experimentally the flexural strength of the PET -concrete blends and the thermal degradation of the PET in the concrete, when the blends with 10 and 20% in volume of PET were exposed to different temperatures (200, 400, 600 °C). The flexural strength of concrete-PET exposed to a heat source is strongly dependent on the temperature, water/cement ratio, as well as the content and particle size of PET. However, the activation energy is affected by the temperature, location of the PET particles on the slabs and the water/cement ratio. Higher water content originates thermal and hydrolytic degradation on the PET, while on the concrete, a higher vapor pressure which causes an increase in crack formation. The values of the activation energy are higher on the center of the slabs than on the surface, since concrete is a poor heat conductor.

  6. Influence of content and particle size of waste pet bottles on concrete behavior at different w/c ratios.

    PubMed

    Albano, C; Camacho, N; Hernández, M; Matheus, A; Gutiérrez, A

    2009-10-01

    The goal of this work was to study the mechanical behavior of concrete with recycled Polyethylene Therephtalate (PET), varying the water/cement ratio (0.50 and 0.60), PET content (10 and 20 vol%) and the particle size. Also, the influence of the thermal degradation of PET in the concrete was studied, when the blends were exposed to different temperatures (200, 400, 600 degrees C). Results indicate that PET-filled concrete, when volume proportion and particle size of PET increased, showed a decrease in compressive strength, splitting tensile strength, modulus of elasticity and ultrasonic pulse velocity; however, the water absorption increased. On the other hand, the flexural strength of concrete-PET when exposed to a heat source was strongly dependent on the temperature, water/cement ratio, as well as on the PET content and particle size. Moreover, the activation energy was affected by the temperature, PET particles location on the slabs and water/cement ratio.

  7. Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 01: Optimization of an organic field effect transistor for radiation dosimetry measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syme, Alasdair

    2016-08-15

    Purpose: To use Monte Carlo simulations to optimize the design of an organic field effect transistor (OFET) to maximize water-equivalence across the diagnostic and therapeutic photon energy ranges. Methods: DOSXYZnrc was used to simulate transport of mono-energetic photon beams through OFETs. Dose was scored in the dielectric region of devices and used for evaluating the response of the device relative to water. Two designs were considered: 1. a bottom-gate device on a substrate of polyethylene terephthalate (PET) with an aluminum gate, a dielectric layer of either PMMA or CYTOP (a fluorocarbon) and an organic semiconductor (pentacene). 2. a symmetric bilayermore » design was employed in which two polymer layers (PET and CYTOP) were deposited both below the gate and above the semiconductor to improve water-equivalence and reduce directional dependence. The relative thickness of the layers was optimized to maximize water-equivalence. Results: Without the bilayer, water-equivalence was diminished relative to OFETs with the symmetric bilayer at low photon energies (below 80 keV). The bilayer’s composition was designed to have one layer with an effective atomic number larger than that of water and the other with an effective atomic number lower than that of water. For the particular materials used in this study, a PET layer 0.1mm thick coupled with a CYTOP layer of 900 nm provided a device with a water-equivalence within 3% between 20 keV and 5 MeV. Conclusions: organic electronic devices hold tremendous potential as water-equivalent dosimeters that could be used in a wide range of applications without recalibration.« less

  8. Assessment of the climatic potential for tourism in Iran through biometeorology clustering.

    PubMed

    Roshan, Gholamreza; Yousefi, Robabe; Błażejczyk, Krzysztof

    2018-04-01

    This study presents a spatiotemporal analysis of bioclimatic comfort conditions for Iran using mean daily meteorological data from 1995 to 2014, analyzed through Physiological Equivalent Temperature (PET) index and Universal Thermal Climate Index (UTCI) indices, and bioclimatic clustering. The results of this study demonstrate that due to the climate variability across Iran during the year, there is at any point in time a location with climatic condition suitable for tourism. Mean values demonstrate maxima in bioclimatic comfort indices for the country in late winter and spring and minima for summer. Seven statistically significant clusters in bioclimatic indices were identified. Comparing these with clustering performed on PET and UTCI, the maximum overlaps between the two indices. In the following, the outputs of this research showed that most appropriate bioclimatic clustering for Iran includes seven clusters. These clustering locations according to climatic suitability for tourism provide a valuable contribution to tourism management in the country, particularly through marketing destinations to maximize tourist flow.

  9. Estimation of the tourism climate in the Hunter Region, Australia, in the early twenty-first century.

    PubMed

    Shiue, Ivy; Matzarakis, Andreas

    2011-07-01

    Existing tourism-related climate information and evaluation are typically based on mean monthly conditions of air temperature and precipitation and do not include thermal perception and other climate parameters relevant for tourists. Here, we quantify climate based on the climate facets relevant to tourism (thermal, physical, aesthetical), and apply the results to the Climate-Tourism-Information-Scheme (CTIS). This paper presents bioclimatic and tourism climatological conditions in the Hunter Region-one of Australia's most popular tourist destinations. In the Hunter Region, generally, temperatures below 15°C occur from April through October, temperatures less than 25°C are expected throughout the whole year, while humidity sits around 50%. As expected, large differences between air temperature and physiologically equivalent temperature (PET) were clearly identified. The widest differences were seen in summer time rather than in the winter period. In addition, cold stress was observed less than 10% of the time in winter while around 40-60% of heat stress was observed in summer time. This correlates with the highest numbers of international visitors, who usually seek a warmer weather, at the beginning of summer time (November and December) and also to the number of domestic visitors, who tend to seek cooler places for recreation and leisure, in late summer (January-March). It was concluded that thermal bioclimate assessment such as PET and CTIS can be applied in the Hunter region, and that local governments and the tourism industry should take an integrated approach to providing more relevant weather and climate information for both domestic and international tourists in the near future.

  10. Estimation of the tourism climate in the Hunter Region, Australia, in the early twenty-first century

    NASA Astrophysics Data System (ADS)

    Shiue, Ivy; Matzarakis, Andreas

    2011-07-01

    Existing tourism-related climate information and evaluation are typically based on mean monthly conditions of air temperature and precipitation and do not include thermal perception and other climate parameters relevant for tourists. Here, we quantify climate based on the climate facets relevant to tourism (thermal, physical, aesthetical), and apply the results to the Climate-Tourism-Information-Scheme (CTIS). This paper presents bioclimatic and tourism climatological conditions in the Hunter Region—one of Australia's most popular tourist destinations. In the Hunter Region, generally, temperatures below 15°C occur from April through October, temperatures less than 25°C are expected throughout the whole year, while humidity sits around 50%. As expected, large differences between air temperature and physiologically equivalent temperature (PET) were clearly identified. The widest differences were seen in summer time rather than in the winter period. In addition, cold stress was observed less than 10% of the time in winter while around 40-60% of heat stress was observed in summer time. This correlates with the highest numbers of international visitors, who usually seek a warmer weather, at the beginning of summer time (November and December) and also to the number of domestic visitors, who tend to seek cooler places for recreation and leisure, in late summer (January-March). It was concluded that thermal bioclimate assessment such as PET and CTIS can be applied in the Hunter region, and that local governments and the tourism industry should take an integrated approach to providing more relevant weather and climate information for both domestic and international tourists in the near future.

  11. Rheological Properties and Foaming Behavior of Poly(Ethylene Terephthalates) Modified with Pyromellitic Dianhydride

    NASA Astrophysics Data System (ADS)

    Yang, Zhao-Ping; Xin, Chun-Ling; Guo, Ya-Feng; Luo, Yi-Wei; He, Ya-Dong

    2016-05-01

    Improving the melt viscoelasticity of poly(ethylene terephthalate) (PET) is a well-known method to obtain foamable PET. The aim of this study is to prepare high melt strength PET and evaluate the influence of rheological properties of PET on the foaming behavior. For this purpose, pyromelliticdianhydride was used as the chain extender to modify a linear PET through melt reactive processing. The rheological properties of the unmodified and modified PETs were measured by a dynamic rheometer. Results showed that the modified PET had higher complex viscosity than the unmodified one. Furthermore, the batch foaming by using supercritical CO2 as a blowing agent was carried to evaluate the foamability of modified PETs. It was found that an enlarged foaming temperature window was obtained for modified PETs compared to unmodified PET. Moreover, the modified PETs foams exhibited higher expansion ratio, smaller cell size and higher cell density at high temperatures than the neat PET.

  12. A comprehensive analysis of physiologically equivalent temperature changes of Iranian selected stations for the last half century

    NASA Astrophysics Data System (ADS)

    Roshan, Gholamreza; Yousefi, Robabe; Kovács, Attila; Matzarakis, Andreas

    2018-01-01

    As a preliminary and major step for land use planning of the coming years, the study of variability of the past decades' climatic conditions with comprehensive indicators is of high importance. Given the fact that one of the affected areas by climatic change includes variability of thermal comfort, this study uses the physiologically equivalent temperature (PET) to identify and evaluate bioclimatic conditions of 40 meteorological stations in Iran. In this study, PET changes for the period of 1960 to 2010 are analyzed, with the use of Mann-Kendall non-parametric test and Pearson parametric method. The study focuses particularly on the diversity in spatio-temporal distribution of Iran's bioclimatic conditions. The findings show that the mean frequency percentage of days with comfort is 12.9 % according to the total number of selected stations. The maximum and minimum frequency percentage with values of 17.4 and 10.3 belong to Kerman and Chabahar stations, respectively. The findings of long-term trend analysis for the period of 1960-2010 show that 55 % of the stations have significant increasing trend in terms of thermal comfort class based on the Pearson method, while it is 40 % based on Mann-Kendall test. The results indicate that the highest frequency of days with thermal comfort in the southern coasts of Iran relates to the end of autumn and winter, nevertheless, such ideal conditions for the coastal cities of Caspian Sea and even central stations of Iran relate to mid-spring and mid-autumn. Late summer and early autumn along with late spring can be identified as the most ideal times in the west and northwest part of Iran. In addition, the most important inhibiting factors of thermal comfort prove to be different across the regions of Iran. For instance, in the southern coasts, warm to very hot bioclimatic events and in the west and northwest regions, cold to very cold conditions turn out to be the most important inhibiting factors. When considering the variations across the studied period, an increase in the frequency of thermal comfort condition is observed in almost half of the stations. Moreover, based on Pearson and Mann-Kendall methods, the trend of changes in monthly averages of PET has decreased in most stations and months, which can lead to different consequences in each month and station. Thus, it is expected that due to PET changes in recent decades and to the intensified global warming conditions, Iran's bioclimatic conditions change in a way that transfers the days with comfort to early spring and late autumn.

  13. Radiation Hardness of dSiPM Sensors in a Proton Therapy Radiation Environment

    NASA Astrophysics Data System (ADS)

    Diblen, Faruk; Buitenhuis, Tom; Solf, Torsten; Rodrigues, Pedro; van der Graaf, Emiel; van Goethem, Marc-Jan; Brandenburg, Sytze; Dendooven, Peter

    2017-07-01

    In vivo verification of dose delivery in proton therapy by means of positron emission tomography (PET) or prompt gamma imaging is mostly based on fast scintillation detectors. The digital silicon photomultiplier (dSiPM) allows excellent scintillation detector timing properties and is thus being considered for such verification methods. We present here the results of the first investigation of radiation damage to dSiPM sensors in a proton therapy radiation environment. Radiation hardness experiments were performed at the AGOR cyclotron facility at the KVI-Center for Advanced Radiation Technology, University of Groningen. A 150-MeV proton beam was fully stopped in a water target. In the first experiment, bare dSiPM sensors were placed at 25 cm from the Bragg peak, perpendicular to the beam direction, a geometry typical for an in situ implementation of a PET or prompt gamma imaging device. In the second experiment, dSiPM-based PET detectors containing lutetium yttrium orthosilicate scintillator crystal arrays were placed at 2 and 4 m from the Bragg peak, perpendicular to the beam direction; resembling an in-room PET implementation. Furthermore, the experimental setup was simulated with a Geant4-based Monte Carlo code in order to determine the angular and energy distributions of the neutrons and to determine the 1-MeV equivalent neutron fluences delivered to the dSiPM sensors. A noticeable increase in dark count rate (DCR) after an irradiation with about 108 1-MeV equivalent neutrons/cm2 agrees with observations by others for analog SiPMs, indicating that the radiation damage occurs in the single photon avalanche diodes and not in the electronics integrated on the sensor chip. It was found that in the in situ location, the DCR becomes too large for successful operation after the equivalent of a few weeks of use in a proton therapy treatment room (about 5 × 1013 protons). For PET detectors in an in-room setup, detector performance was unchanged even after an irradiation equivalent to three years of use in a treatment room (3 × 1015 protons).

  14. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    PubMed

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  15. Photoinduced electron transfer in a room temperature ionic liquid 1-butyl-3-methylimidazolium octyl sulfate micelle: a temperature dependent study.

    PubMed

    Sarkar, Souravi; Mandal, Sarthak; Pramanik, Rajib; Ghatak, Chiranjib; Rao, Vishal Govind; Sarkar, Nilmoni

    2011-05-19

    The effect of temperature on the dynamics of photoinduced electron transfer (PET) between different coumarin dyes and N,N-dimethyl aniline in a room temperature ionic liquid 1-butyl-3-methylimidazolium octyl sulfate ([C(4)mim][C(8)SO(4)]) micelle have been investigated using steady-state and time-resolved fluorescence quenching measurements at four different temperatures: 208, 298, 308, and 318 K. The quenching rates (k(q)(TR)) of the PET process in this micellar system are found to be lower than the PET rate in sodium dodecyl sulfate and Triton-X 100 micelle and almost comparable to the dodecyl trimethyl ammonium bromide and cetyl trimethyl ammonium bromide micelle due to larger donor–acceptor separation in the micellar phase. The temperature dependent PET rates are well correlated with the Arrhenius type of correlation for all the coumarin dyes. Marcus type of inversion in PET rates has been observed at relatively lower exergonicity, and the correlation plots gradually move upward with the increase of temperature. © 2011 American Chemical Society

  16. Comparison of 18F-FDG PET/CT and PET/MRI in patients with multiple myeloma

    PubMed Central

    Sachpekidis, Christos; Hillengass, Jens; Goldschmidt, Hartmut; Mosebach, Jennifer; Pan, Leyun; Schlemmer, Heinz-Peter; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2015-01-01

    PET/MRI represents a promising hybrid imaging modality with several potential clinical applications. Although PET/MRI seems highly attractive in the diagnostic approach of multiple myeloma (MM), its role has not yet been evaluated. The aims of this prospective study are to evaluate the feasibility of 18F-FDG PET/MRI in detection of MM lesions, and to investigate the reproducibility of bone marrow lesions detection and quantitative data of 18F-FDG uptake between the functional (PET) component of PET/CT and PET/MRI in MM patients. The study includes 30 MM patients. All patients initially underwent 18F-FDG PET/CT (60 min p.i.), followed by PET/MRI (120 min p.i.). PET/CT and PET/MRI data were assessed and compared based on qualitative (lesion detection) and quantitative (SUV) evaluation. The hybrid PET/MRI system provided good image quality in all cases without artefacts. PET/MRI identified 65 of the 69 lesions, which were detectable with PET/CT (94.2%). Quantitative PET evaluations showed the following mean values in MM lesions: SUVaverage=5.5 and SUVmax=7.9 for PET/CT; SUVaverage=3.9 and SUVmax=5.8 for PET/MRI. Both SUVaverage and SUVmax were significantly higher on PET/CT than on PET/MRI. Spearman correlation analysis demonstrated a strong correlation between both lesional SUVaverage (r=0.744) and lesional SUVmax (r=0.855) values derived from PET/CT and PET/MRI. Regarding detection of myeloma skeletal lesions, PET/MRI exhibited equivalent performance to PET/CT. In terms of tracer uptake quantitation, a significant correlation between the two techniques was demonstrated, despite the statistically significant differences in lesional SUVs between PET/CT and PET/MRI. PMID:26550538

  17. The use of noise equivalent count rate and the NEMA phantom for PET image quality evaluation.

    PubMed

    Yang, Xin; Peng, Hao

    2015-03-01

    PET image quality is directly associated with two important parameters among others: count-rate performance and image signal-to-noise ratio (SNR). The framework of noise equivalent count rate (NECR) was developed back in the 1990s and has been widely used since then to evaluate count-rate performance for PET systems. The concept of NECR is not entirely straightforward, however, and among the issues requiring clarification are its original definition, its relationship to image quality, and its consistency among different derivation methods. In particular, we try to answer whether a higher NECR measurement using a standard NEMA phantom actually corresponds to better imaging performance. The paper includes the following topics: 1) revisiting the original analytical model for NECR derivation; 2) validating three methods for NECR calculation based on the NEMA phantom/standard; and 3) studying the spatial dependence of NECR and quantitative relationship between NECR and image SNR. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Regional potential evapotranspiration in arid climates based on temperature, topography and calculated solar radiation

    NASA Astrophysics Data System (ADS)

    Shevenell, Lisa

    1999-03-01

    Values of evapotranspiration are required for a variety of water planning activities in arid and semi-arid climates, yet data requirements are often large, and it is costly to obtain this information. This work presents a method where a few, readily available data (temperature, elevation) are required to estimate potential evapotranspiration (PET). A method using measured temperature and the calculated ratio of total to vertical radiation (after the work of Behnke and Maxey, 1969) to estimate monthly PET was applied for the months of April-October and compared with pan evaporation measurements. The test area used in this work was in Nevada, which has 124 weather stations that record sufficient amounts of temperature data. The calculated PET values were found to be well correlated (R2=0·940-0·983, slopes near 1·0) with mean monthly pan evaporation measurements at eight weather stations.In order to extrapolate these calculated PET values to areas without temperature measurements and to sites at differing elevations, the state was divided into five regions based on latitude, and linear regressions of PET versus elevation were calculated for each of these regions. These extrapolated PET values generally compare well with the pan evaporation measurements (R2=0·926-0·988, slopes near 1·0). The estimated values are generally somewhat lower than the pan measurements, in part because the effects of wind are not explicitly considered in the calculations, and near-freezing temperatures result in a calculated PET of zero at higher elevations in the spring months. The calculated PET values for April-October are 84-100% of the measured pan evaporation values. Using digital elevation models in a geographical information system, calculated values were adjusted for slope and aspect, and the data were used to construct a series of maps of monthly PET. The resultant maps show a realistic distribution of regional variations in PET throughout Nevada which inversely mimics topography. The general methods described here could be used to estimate regional PET in other arid western states (e.g. New Mexico, Arizona, Utah) and arid regions world-wide (e.g. parts of Africa).

  19. Estimation of Hoffman-Lauritzen parameters from nonisothermal crystallization kinetics of PET/MWCNT nanocomposites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaonkar, Amita, E-mail: ami.gaonkar@gmail.com; Murudkar, Vrishali, E-mail: vru0077@gmail.com; Deshpande, V. D., E-mail: vindesh2@rediffmail.com

    2016-05-06

    Polyethylene terephthalate (PET) and Nucleated PET/ multi-walled carbon nanotubes (MWCNTs) nanocomposites with different MWCNTs loadings were prepared by melt compounding. The influence of the addition of MWCNTs and precipitated PET (p-PET) on the morphology and thermal properties of the nanocomposites was investigated. From Transmission Electronic Microscopy (TEM) and Wide angle X-Ray diffraction (WAXD) study, it can be clearly seen that nanocomposites with low MWCNTs contents (0.1 wt. %) get better MWCNTs dispersion than higher MWCNT loading. Comparing with PET, nucleated PET nanocomposite with 0.1% MWCNT loading shows higher value of Lauritzen-Hoffman parameters U* and Kg evaluated using the differential isoconversionalmore » method. Crystallization regime transition temperature range shifts to higher temperature (208°C - 215°C) for nanocomposites. The presence of p-PET in addition of MWCNT, which act as good nucleating agent, enhanced the crystallization of PET through heterogeneous nucleation.« less

  20. Estimation of Hoffman-Lauritzen parameters from nonisothermal crystallization kinetics of PET/MWCNT nanocomposites

    NASA Astrophysics Data System (ADS)

    Gaonkar, Amita; Murudkar, Vrishali; Deshpande, V. D.

    2016-05-01

    Polyethylene terephthalate (PET) and Nucleated PET/ multi-walled carbon nanotubes (MWCNTs) nanocomposites with different MWCNTs loadings were prepared by melt compounding. The influence of the addition of MWCNTs and precipitated PET (p-PET) on the morphology and thermal properties of the nanocomposites was investigated. From Transmission Electronic Microscopy (TEM) and Wide angle X-Ray diffraction (WAXD) study, it can be clearly seen that nanocomposites with low MWCNTs contents (0.1 wt. %) get better MWCNTs dispersion than higher MWCNT loading. Comparing with PET, nucleated PET nanocomposite with 0.1% MWCNT loading shows higher value of Lauritzen-Hoffman parameters U* and Kg evaluated using the differential isoconversional method. Crystallization regime transition temperature range shifts to higher temperature (208°C - 215°C) for nanocomposites. The presence of p-PET in addition of MWCNT, which act as good nucleating agent, enhanced the crystallization of PET through heterogeneous nucleation.

  1. Comparison of UTCI with Other Thermal Indices in the Assessment of Heat and Cold Effects on Cardiovascular Mortality in the Czech Republic

    PubMed Central

    Urban, Aleš; Kyselý, Jan

    2014-01-01

    We compare the recently developed Universal Thermal Climate Index (UTCI) with other thermal indices in analysing heat- and cold-related effects on cardiovascular (CVD) mortality in two different (urban and rural) regions in the Czech Republic during the 16-year period from 1994–2009. Excess mortality is represented by the number of deaths above expected daily values, the latter being adjusted for long-term changes, annual and weekly cycles, and epidemics of influenza/acute respiratory infections. Air temperature, UTCI, Apparent Temperature (AT) and Physiologically Equivalent Temperature (PET) are applied to identify days with heat and cold stress. We found similar heat effects on CVD mortality for air temperature and the examined thermal indices. Responses of CVD mortality to cold effects as characterised by different indices were much more varied. Particularly important is the finding that air temperature provides a weak cold effect in comparison with the thermal indices in both regions, so its application—still widespread in epidemiological studies—may underestimate the magnitude of cold-related mortality. These findings are important when possible climate change effects on heat- and cold-related mortality are estimated. AT and PET appear to be more universal predictors of heat- and cold- related mortality than UTCI when both urban and rural environments are of concern. UTCI tends to select windy rather than freezing days in winter, though these show little effect on mortality in the urban population. By contrast, significant cold-related mortality in the rural region if UTCI is used shows potential for UTCI to become a useful tool in cold exposure assessments. PMID:24413706

  2. Solar Disinfection of Viruses in Polyethylene Terephthalate Bottles

    PubMed Central

    Carratalà, Anna; Dionisio Calado, Alex; Mattle, Michael J.; Meierhofer, Regula; Luzi, Samuel

    2015-01-01

    Solar disinfection (SODIS) of drinking water in polyethylene terephthalate (PET) bottles is a simple, efficient point-of-use technique for the inactivation of many bacterial pathogens. In contrast, the efficiency of SODIS against viruses is not well known. In this work, we studied the inactivation of bacteriophages (MS2 and ϕX174) and human viruses (echovirus 11 and adenovirus type 2) by SODIS. We conducted experiments in PET bottles exposed to (simulated) sunlight at different temperatures (15, 22, 26, and 40°C) and in water sources of diverse compositions and origins (India and Switzerland). Good inactivation of MS2 (>6-log inactivation after exposure to a total fluence of 1.34 kJ/cm2) was achieved in Swiss tap water at 22°C, while less-efficient inactivation was observed in Indian waters and for echovirus (1.5-log inactivation at the same fluence). The DNA viruses studied, ϕX174 and adenovirus, were resistant to SODIS, and the inactivation observed was equivalent to that occurring in the dark. High temperatures enhanced MS2 inactivation substantially; at 40°C, 3-log inactivation was achieved in Swiss tap water after exposure to a fluence of only 0.18 kJ/cm2. Overall, our findings demonstrate that SODIS may reduce the load of single-stranded RNA (ssRNA) viruses, such as echoviruses, particularly at high temperatures and in photoreactive matrices. In contrast, complementary measures may be needed to ensure efficient inactivation during SODIS of DNA viruses resistant to oxidation. PMID:26497451

  3. Influence of photon energy cuts on PET Monte Carlo simulation results.

    PubMed

    Mitev, Krasimir; Gerganov, Georgi; Kirov, Assen S; Schmidtlein, C Ross; Madzhunkov, Yordan; Kawrakow, Iwan

    2012-07-01

    The purpose of this work is to study the influence of photon energy cuts on the results of positron emission tomography (PET) Monte Carlo (MC) simulations. MC simulations of PET scans of a box phantom and the NEMA image quality phantom are performed for 32 photon energy cut values in the interval 0.3-350 keV using a well-validated numerical model of a PET scanner. The simulations are performed with two MC codes, egs_pet and GEANT4 Application for Tomographic Emission (GATE). The effect of photon energy cuts on the recorded number of singles, primary, scattered, random, and total coincidences as well as on the simulation time and noise-equivalent count rate is evaluated by comparing the results for higher cuts to those for 1 keV cut. To evaluate the effect of cuts on the quality of reconstructed images, MC generated sinograms of PET scans of the NEMA image quality phantom are reconstructed with iterative statistical reconstruction. The effects of photon cuts on the contrast recovery coefficients and on the comparison of images by means of commonly used similarity measures are studied. For the scanner investigated in this study, which uses bismuth germanate crystals, the transport of Bi X(K) rays must be simulated in order to obtain unbiased estimates for the number of singles, true, scattered, and random coincidences as well as for an unbiased estimate of the noise-equivalent count rate. Photon energy cuts higher than 170 keV lead to absorption of Compton scattered photons and strongly increase the number of recorded coincidences of all types and the noise-equivalent count rate. The effect of photon cuts on the reconstructed images and the similarity measures used for their comparison is statistically significant for very high cuts (e.g., 350 keV). The simulation time decreases slowly with the increase of the photon cut. The simulation of the transport of characteristic x rays plays an important role, if an accurate modeling of a PET scanner system is to be achieved. The simulation time decreases slowly with the increase of the cut which, combined with the accuracy loss at high cuts, means that the usage of high photon energy cuts is not recommended for the acceleration of MC simulations.

  4. Human thermal comfort conditions and urban planning in hot-humid climates—The case of Cuba

    NASA Astrophysics Data System (ADS)

    Rodríguez Algeciras, José Abel; Coch, Helena; De la Paz Pérez, Guillermo; Chaos Yeras, Mabel; Matzarakis, Andreas

    2016-08-01

    Climate regional characteristics, urban environmental conditions, and outdoors thermal comfort requirements of residents are important for urban planning. Basic studies of urban microclimate can provide information and useful resources to predict and improve thermal conditions in hot-humid climatic regions. The paper analyzes the thermal bioclimate and its influence as urban design factor in Cuba, using Physiologically Equivalent Temperature (PET). Simulations of wind speed variations and shade conditions were performed to quantify changes in thermal bioclimate due to possible modifications in urban morphology. Climate data from Havana, Camagüey, and Santiago of Cuba for the period 2001 to 2012 were used to calculate PET with the RayMan model. The results show that changes in meteorological parameters influence the urban microclimate, and consequently modify the thermal conditions in outdoors spaces. Shade is the predominant strategy to improve urban microclimate with more significant benefits in terms of PET higher than 30 °C. For climatic regions such as the analyzed ones, human thermal comfort can be improved by a wind speed modification for thresholds of PET above 30 °C, and by a wind speed decreases in conditions below 26 °C. The improvement of human thermal conditions is crucial for urban sustainability. On this regards, our study is a contribution for urban designers, due to the possibility of taking advantage of results for improving microclimatic conditions based on urban forms. The results may enable urban planners to create spaces that people prefer to visit, and also are usable in the reconfiguration of cities.

  5. Implementation of human thermal comfort information in Köppen-Geiger climate classification—the example of China

    NASA Astrophysics Data System (ADS)

    Yang, Shi-Qi; Matzarakis, Andreas

    2016-11-01

    Köppen-Geiger climate classification (KGC) is accepted and applied worldwide. The climatic parameters utilised in KGC, however, cannot indicate human thermal comfort (HTC) conditions or air humidity (AH) conditions directly, because they are originally based on climatic effects on vegetation, instead of that on human body directly. In addition, HTC is driven by meteorological parameters together. Thus, the objective of this study is to preliminarily implement the HTC information and the AH information in KGC. Physiologically equivalent temperature (PET) has been chosen as the HTC index, and vapour pressure (VP) is for the quantification of AH conditions. In this preliminary study, 12 Chinese cities in total have been taken into account as the assumed representatives of 11 climate types. Basic meteorological data of each city with 3-h resolution in 2000-2012 has been analysed. RayMan model has been applied to calculate PET within the same time period. Each climate type has been described by frequencies of PET and frequencies of VP. For example, the Aw (Sanya) has the most frequent occurrence of thermally stressful conditions compared to other climate types: PET in 22 % points in time of the year was above 35 °C. The driest AH conditions existed in Dwc (Lhasa) and Dfb (Urumqi) with VP rarely above 18 hPa in the wettest month. Implementation of the HTC information and the additional AH information in each climate type of KGC can be helpful for the topics of human health, energy consumption, tourism, as well as urban planning.

  6. Implementation of human thermal comfort information in Köppen-Geiger climate classification-the example of China.

    PubMed

    Yang, Shi-Qi; Matzarakis, Andreas

    2016-11-01

    Köppen-Geiger climate classification (KGC) is accepted and applied worldwide. The climatic parameters utilised in KGC, however, cannot indicate human thermal comfort (HTC) conditions or air humidity (AH) conditions directly, because they are originally based on climatic effects on vegetation, instead of that on human body directly. In addition, HTC is driven by meteorological parameters together. Thus, the objective of this study is to preliminarily implement the HTC information and the AH information in KGC. Physiologically equivalent temperature (PET) has been chosen as the HTC index, and vapour pressure (VP) is for the quantification of AH conditions. In this preliminary study, 12 Chinese cities in total have been taken into account as the assumed representatives of 11 climate types. Basic meteorological data of each city with 3-h resolution in 2000-2012 has been analysed. RayMan model has been applied to calculate PET within the same time period. Each climate type has been described by frequencies of PET and frequencies of VP. For example, the Aw (Sanya) has the most frequent occurrence of thermally stressful conditions compared to other climate types: PET in 22 % points in time of the year was above 35 °C. The driest AH conditions existed in Dwc (Lhasa) and Dfb (Urumqi) with VP rarely above 18 hPa in the wettest month. Implementation of the HTC information and the additional AH information in each climate type of KGC can be helpful for the topics of human health, energy consumption, tourism, as well as urban planning.

  7. Human thermal comfort conditions and urban planning in hot-humid climates-The case of Cuba.

    PubMed

    Rodríguez Algeciras, José Abel; Coch, Helena; De la Paz Pérez, Guillermo; Chaos Yeras, Mabel; Matzarakis, Andreas

    2016-08-01

    Climate regional characteristics, urban environmental conditions, and outdoors thermal comfort requirements of residents are important for urban planning. Basic studies of urban microclimate can provide information and useful resources to predict and improve thermal conditions in hot-humid climatic regions. The paper analyzes the thermal bioclimate and its influence as urban design factor in Cuba, using Physiologically Equivalent Temperature (PET). Simulations of wind speed variations and shade conditions were performed to quantify changes in thermal bioclimate due to possible modifications in urban morphology. Climate data from Havana, Camagüey, and Santiago of Cuba for the period 2001 to 2012 were used to calculate PET with the RayMan model. The results show that changes in meteorological parameters influence the urban microclimate, and consequently modify the thermal conditions in outdoors spaces. Shade is the predominant strategy to improve urban microclimate with more significant benefits in terms of PET higher than 30 °C. For climatic regions such as the analyzed ones, human thermal comfort can be improved by a wind speed modification for thresholds of PET above 30 °C, and by a wind speed decreases in conditions below 26 °C. The improvement of human thermal conditions is crucial for urban sustainability. On this regards, our study is a contribution for urban designers, due to the possibility of taking advantage of results for improving microclimatic conditions based on urban forms. The results may enable urban planners to create spaces that people prefer to visit, and also are usable in the reconfiguration of cities.

  8. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    NASA Astrophysics Data System (ADS)

    Yoshida, Eiji; Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo

    2010-09-01

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  9. NEMA NU 4-2008 Performance Measurements of Two Commercial Small-Animal PET Scanners: ClearPET and rPET-1

    NASA Astrophysics Data System (ADS)

    Canadas, Mario; Embid, Miguel; Lage, Eduardo; Desco, Manuel; Vaquero, Juan José; Perez, José Manuel

    2011-02-01

    In this work, we compare two commercial positron emission tomography (PET) scanners installed at CIEMAT (Madrid, Spain): the ClearPET and the rPET-1. These systems have significant geometrical differences, such as the axial field of view (110 mm on ClearPET versus 45.6 mm on rPET-1), the configuration of the detectors (whole ring on ClearPET versus one pair of planar blocks on rPET-1) and the use of an axial shift between ClearPET detector modules. We used an assessment procedure that fulfilled the recommendations of the National Electrical Manufacturers Association (NEMA) NU 4-2008 standard. The methodology includes studies of spatial resolution, sensitivity, scatter fraction, count losses and image quality. Our experiments showed a central spatial resolution of 1.5 mm (transaxial), 3.2 mm (axial) for the ClearPET and 1.5 mm (transaxial), 1.6 mm (axial) for the rPET-1, with a small variation across the transverse axis on both scanners ( 1 mm). The absolute sensitivity at the centre of the field of view was 4.7% for the ClearPET and 1.0% for the rPET-1. The peak noise equivalent counting rate for the mouse-sized phantom was 73.4 kcps reached at 0.51 MBq/mL on the ClearPET and 29.2 kcps at 1.35 MBq/mL on the rPET-1. The recovery coefficients measured using the image quality phantom ranged from 0.11 to 0.89 on the ClearPET and from 0.14 to 0.81 on the rPET-1. The overall performance shows that both the ClearPET and the rPET-1 systems are very suitable for preclinical research and imaging of small animals.

  10. Adhesion of nitrile rubber (NBR) to polyethylene terephthalate (PET) fabric. Part 1: PET surface modification by methylenediphenyl di-isocyanate (MDI)

    NASA Astrophysics Data System (ADS)

    Razavizadeh, Mahmoud; Jamshidi, Masoud

    2016-01-01

    Fiber to rubber adhesion is an important subject in rubber composite industry. It is well known that surface physical, mechanical and chemical treatments are effective methods to improve interfacial bonding. Ultra violet (UV) light irradiation is an efficient method which is used to increase interfacial interactions. In this research UV assisted chemical modification of PET fabric was used to increase its bonding to nitrile rubber (NBR). NBR is perfect selection to produce fuel and oil resistant rubber parts but it has weak bonding to fabrics. For this purpose at first, the PET fabric was carboxylated under UV irradiation and then methylenediphenyl diisocyanate (MDI) was reacted and grafted to carboxylated PET. T-peel test was used to evaluate PET fabric to NBR bonding strength. Attenuated total reflectance-Fourier transform infrared spectroscopy (FTIR-AT) was used to assess surface modifications of the PET fabrics. The chemical composition of the PET surfaces before and after carboxylation and MDI grafting was investigated by X-ray photoelectron spectroscopy (XPS). It was found that at vulcanizing temperature of 150 °C, carboxylation in contrary to MDI grafting, improved considerably PET to NBR adhesion. Finally effect of curing temperature on PET to NBR bonding strength was determined. It was found that increasing vulcanizing temperature to 170 °C caused considerable improvement (about 134%) in bonding strength.

  11. Dynamic-compliance and viscosity of PET and PEN

    NASA Astrophysics Data System (ADS)

    Weick, Brian L.

    2016-05-01

    Complex dynamic-compliance and in-phase dynamic-viscosity data are presented and analyzed for PET and PEN advanced polyester substrates used for magnetic tapes. Frequency-temperature superposition is used to predict long-term behavior. Temperature and frequency ranges for the primary glass transition and secondary transitions are discussed and compared for PET and PEN. Shift factors from frequency-temperature superposition are used to determine activation energies for the transitions, and WLF parameters are determined for the polyester substrates.

  12. Dynamic-compliance and viscosity of PET and PEN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weick, Brian L.

    Complex dynamic-compliance and in-phase dynamic-viscosity data are presented and analyzed for PET and PEN advanced polyester substrates used for magnetic tapes. Frequency-temperature superposition is used to predict long-term behavior. Temperature and frequency ranges for the primary glass transition and secondary transitions are discussed and compared for PET and PEN. Shift factors from frequency-temperature superposition are used to determine activation energies for the transitions, and WLF parameters are determined for the polyester substrates.

  13. The extreme heat wave in Athens in July 1987 from the point of view of human biometeorology

    NASA Astrophysics Data System (ADS)

    Matzarakis, Andreas; Mayer, Helmut

    At the end of July 1987 a heat wave came over Greece and had as a consequence an increase in the mortality to double the normal values. Predicted mean vote ( PMV), physiologically equivalent temperature ( PET), and for comparison discomfort index ( DI) as thermal indices as well as core temperature, mean skin temperature, and skin wetness as body parameters are calculated for that period based on meteorological data of the Meteorological Institute of the National Observatory in the centre of Athens and of the suburban station New Philadelphia of the Hellenic National Weather Service. The results for the thermal indices and the body parameters indicate a very high thermal stress on people. In addition, the air quality stress index ( AQSI) has been used for characterizing air quality conditions in Athens during the heat wave. The results Combined with the thermal effects of the heat wave the stress on humans due to environmental conditions has been very injurious to health.

  14. Preparation and in vivo characterization of 51MnCl2 as PET tracer of Ca2+ channel-mediated transport.

    PubMed

    Graves, Stephen A; Hernandez, Reinier; Valdovinos, Hector F; Ellison, Paul A; Engle, Jonathan W; Barnhart, Todd E; Cai, Weibo; Nickles, Robert J

    2017-06-08

    Manganese has long been employed as a T 1 -shortening agent in magnetic resonance imaging (MRI) applications, but these techniques are limited by the biotoxicity of bulk-manganese. Positron emission tomography (PET) offers superior contrast sensitivity compared with MRI, and recent preclinical PET studies employing 52g Mn (t 1/2 : 5.6 d, β + : 29%) show promise for a variety of applications including cell tracking, neural tract tracing, immunoPET, and functional β-cell mass quantification. The half-life and confounding gamma emissions of 52g Mn are prohibitive to clinical translation, but the short-lived 51 Mn (t 1/2 : 46 min, β + : 97%) represents a viable alternative. This work develops methods to produce 51 Mn on low-energy medical cyclotrons, characterizes the in vivo behavior of 51 MnCl 2 in mice, and performs preliminary human dosimetry predictions. 51 Mn was produced by proton irradiation of electrodeposited isotopically-enriched 54 Fe targets. Radiochemically isolated 51 MnCl 2 was intravenously administered to ICR mice which were scanned by dynamic and static PET, followed by ex vivo gamma counting. Rapid blood clearance was observed with stable uptake in the pancreas, kidneys, liver, heart, and salivary gland. Dosimetry calculations predict that 370 MBq of 51 Mn in an adult human male would yield an effective dose equivalent of approximately 13.5 mSv, roughly equivalent to a clinical [ 18 F]-FDG procedure.

  15. Using Virtual Pets to Promote Physical Activity in Children: An Application of the Youth Physical Activity Promotion Model.

    PubMed

    Ahn, Sun Joo Grace; Johnsen, Kyle; Robertson, Tom; Moore, James; Brown, Scott; Marable, Amanda; Basu, Aryabrata

    2015-01-01

    A virtual pet was developed based on the framework of the youth physical activity promotion model and tested as a vehicle for promoting physical activity in children. Children in the treatment group interacted with the virtual pet for three days, setting physical activity goals and teaching tricks to the virtual pet when their goals were met. The virtual pet became more fit and learned more sophisticated tricks as the children achieved activity goals. Children in the control group interacted with a computer system presenting equivalent features but without the virtual pet. Physical activity and goal attainment were evaluated using activity monitors. Results indicated that children in the treatment group engaged in 1.09 more hours of daily physical activity (156% more) than did those in the control group. Physical activity self-efficacy and beliefs served as mediators driving this increase in activity. Children that interacted with the virtual pet also expressed higher intentions than children in the control group to continue physical activity in the future. Theoretical and practical potentials of using a virtual pet to systematically promote physical activity in children are discussed.

  16. Do TSH, FT3, and FT4 Impact BAT Visualization of Clinical FDG-PET/CT Images?

    PubMed

    Nishii, Ryuichi; Nagamachi, Shigeki; Mizutani, Youichi; Terada, Tamasa; Kiyohara, Syogo; Wakamatsu, Hideyuki; Fujita, Seigo; Higashi, Tatsuya; Yoshinaga, Keiichiro; Saga, Tsuneo; Hirai, Toshinori

    2018-01-01

    We retrospectively analyzed activated BAT visualization on FDG-PET/CT in patients with various conditions and TH levels to clarify the relationships between visualization of BAT on FDG-PET/CT and the effect of TH. Patients who underwent clinical FDG-PET/CT were reviewed and we categorized patients into 5 groups: (i) thyroid hormone withdrawal (THW) group; (ii) recombinant human thyrotropin (rhTSH) group; (iii) hypothyroidism group; (iv) hyperthyroidism group; and (v) BAT group. A total of sixty-two FDG-PET/CT imaging studies in fifty-nine patients were performed. To compare each group, gender; age; body weight; serum TSH, FT3, and FT4 levels; and outside temperature were evaluated. No significant visualization of BAT was noted in any of the images in the THW, rhTSH, hypothyroidism, and hyperthyroidism groups. All patients in the BAT group were in a euthyroid state. When the BAT-negative and BAT-positive patient groups were compared, it was noted that the minimum and maximum temperature on the day of the PET study and maximum temperature of the one day before the PET study were significantly lower in BAT-positive group than in all those of other groups. Elevated TSH condition before RIT, hyperthyroidism, or hypothyroidism did not significantly impact BAT visualization of clinical FDG-PET/CT images.

  17. Active Site Flexibility as a Hallmark for Efficient PET Degradation by I. sakaiensis PETase.

    PubMed

    Fecker, Tobias; Galaz-Davison, Pablo; Engelberger, Felipe; Narui, Yoshie; Sotomayor, Marcos; Parra, Loreto P; Ramírez-Sarmiento, César A

    2018-03-27

    Polyethylene terephthalate (PET) is one of the most-consumed synthetic polymers, with an annual production of 50 million tons. Unfortunately, PET accumulates as waste and is highly resistant to biodegradation. Recently, fungal and bacterial thermophilic hydrolases were found to catalyze PET hydrolysis with optimal activities at high temperatures. Strikingly, an enzyme from Ideonella sakaiensis, termed PETase, was described to efficiently degrade PET at room temperature, but the molecular basis of its activity is not currently understood. Here, a crystal structure of PETase was determined at 2.02 Å resolution and employed in molecular dynamics simulations showing that the active site of PETase has higher flexibility at room temperature than its thermophilic counterparts. This flexibility is controlled by a novel disulfide bond in its active site, with its removal leading to destabilization of the catalytic triad and reduction of the hydrolase activity. Molecular docking of a model substrate predicts that PET binds to PETase in a unique and energetically favorable conformation facilitated by several residue substitutions within its active site when compared to other enzymes. These computational predictions are in excellent agreement with recent mutagenesis and PET film degradation analyses. Finally, we rationalize the increased catalytic activity of PETase at room temperature through molecular dynamics simulations of enzyme-ligand complexes for PETase and other thermophilic PET-degrading enzymes at 298, 323, and 353 K. Our results reveal that both the binding pose and residue substitutions within PETase favor proximity between the catalytic residues and the labile carbonyl of the substrate at room temperature, suggesting a more favorable hydrolytic reaction. These results are valuable for enabling detailed evolutionary analysis of PET-degrading enzymes and for rational design endeavors aiming at increasing the efficiency of PETase and similar enzymes toward plastic degradation. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  18. Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT.

    PubMed

    Wiesmüller, Marco; Quick, Harald H; Navalpakkam, Bharath; Lell, Michael M; Uder, Michael; Ritt, Philipp; Schmidt, Daniela; Beck, Michael; Kuwert, Torsten; von Gall, Carl C

    2013-01-01

    PET/MR hybrid scanners have recently been introduced, but not yet validated. The aim of this study was to compare the PET components of a PET/CT hybrid system and of a simultaneous whole-body PET/MR hybrid system with regard to reproducibility of lesion detection and quantitation of tracer uptake. A total of 46 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 88 min later a second scan using a hybrid PET/MR system. The radioactive tracers used were (18)F-deoxyglucose (FDG), (18)F-ethylcholine (FEC) and (68)Ga-DOTATATE (Ga-DOTATATE). The PET images from PET/CT (PET(CT)) and from PET/MR (PET(MR)) were analysed for tracer-positive lesions. Regional tracer uptake in these foci was quantified using volumes of interest, and maximal and average standardized uptake values (SUV(max) and SUV(avg), respectively) were calculated. Of the 46 patients, 43 were eligible for comparison and statistical analysis. All lesions except one identified by PET(CT) were identified by PET(MR) (99.2 %). In 38 patients (88.4 %), the same number of foci were identified by PET(CT) and by PET(MR). In four patients, more lesions were identified by PET(MR) than by PET(CT), in one patient PET(CT) revealed an additional focus compared to PET(MR). The mean SUV(max) and SUV(avg) of all lesions determined by PET(MR) were by 21 % and 11 % lower, respectively, than the values determined by PET(CT) (p < 0.05), and a strong correlation between these variables was identified (Spearman rho 0.835; p < 0.01). PET/MR showed equivalent performance in terms of qualitative lesion detection to PET/CT. The differences demonstrated in quantitation of tracer uptake between PET(CT) and PET(MR) were minor, but statistically significant. Nevertheless, a more detailed study of the quantitative accuracy of PET(MR) and the factors governing it is needed to ultimately assess its accuracy in measuring tissue tracer concentrations.

  19. Solar Disinfection of Viruses in Polyethylene Terephthalate Bottles.

    PubMed

    Carratalà, Anna; Dionisio Calado, Alex; Mattle, Michael J; Meierhofer, Regula; Luzi, Samuel; Kohn, Tamar

    2016-01-01

    Solar disinfection (SODIS) of drinking water in polyethylene terephthalate (PET) bottles is a simple, efficient point-of-use technique for the inactivation of many bacterial pathogens. In contrast, the efficiency of SODIS against viruses is not well known. In this work, we studied the inactivation of bacteriophages (MS2 and ϕX174) and human viruses (echovirus 11 and adenovirus type 2) by SODIS. We conducted experiments in PET bottles exposed to (simulated) sunlight at different temperatures (15, 22, 26, and 40°C) and in water sources of diverse compositions and origins (India and Switzerland). Good inactivation of MS2 (>6-log inactivation after exposure to a total fluence of 1.34 kJ/cm(2)) was achieved in Swiss tap water at 22°C, while less-efficient inactivation was observed in Indian waters and for echovirus (1.5-log inactivation at the same fluence). The DNA viruses studied, ϕX174 and adenovirus, were resistant to SODIS, and the inactivation observed was equivalent to that occurring in the dark. High temperatures enhanced MS2 inactivation substantially; at 40°C, 3-log inactivation was achieved in Swiss tap water after exposure to a fluence of only 0.18 kJ/cm(2). Overall, our findings demonstrate that SODIS may reduce the load of single-stranded RNA (ssRNA) viruses, such as echoviruses, particularly at high temperatures and in photoreactive matrices. In contrast, complementary measures may be needed to ensure efficient inactivation during SODIS of DNA viruses resistant to oxidation. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  20. Modelling thermal comfort of visitors at urban squares in hot and arid climate using NN-ARX soft computing method

    NASA Astrophysics Data System (ADS)

    Kariminia, Shahab; Motamedi, Shervin; Shamshirband, Shahaboddin; Piri, Jamshid; Mohammadi, Kasra; Hashim, Roslan; Roy, Chandrabhushan; Petković, Dalibor; Bonakdari, Hossein

    2016-05-01

    Visitors utilize the urban space based on their thermal perception and thermal environment. The thermal adaptation engages the user's behavioural, physiological and psychological aspects. These aspects play critical roles in user's ability to assess the thermal environments. Previous studies have rarely addressed the effects of identified factors such as gender, age and locality on outdoor thermal comfort, particularly in hot, dry climate. This study investigated the thermal comfort of visitors at two city squares in Iran based on their demographics as well as the role of thermal environment. Assessing the thermal comfort required taking physical measurement and questionnaire survey. In this study, a non-linear model known as the neural network autoregressive with exogenous input (NN-ARX) was employed. Five indices of physiological equivalent temperature (PET), predicted mean vote (PMV), standard effective temperature (SET), thermal sensation votes (TSVs) and mean radiant temperature ( T mrt) were trained and tested using the NN-ARX. Then, the results were compared to the artificial neural network (ANN) and the adaptive neuro-fuzzy inference system (ANFIS). The findings showed the superiority of the NN-ARX over the ANN and the ANFIS. For the NN-ARX model, the statistical indicators of the root mean square error (RMSE) and the mean absolute error (MAE) were 0.53 and 0.36 for the PET, 1.28 and 0.71 for the PMV, 2.59 and 1.99 for the SET, 0.29 and 0.08 for the TSV and finally 0.19 and 0.04 for the T mrt.

  1. Initial evaluation of the Celesteion large-bore PET/CT scanner in accordance with the NEMA NU2-2012 standard and the Japanese guideline for oncology FDG PET/CT data acquisition protocol version 2.0.

    PubMed

    Kaneta, Tomohiro; Ogawa, Matsuyoshi; Motomura, Nobutoku; Iizuka, Hitoshi; Arisawa, Tetsu; Hino-Shishikura, Ayako; Yoshida, Keisuke; Inoue, Tomio

    2017-10-11

    The goal of this study was to evaluate the performance of the Celesteion positron emission tomography/computed tomography (PET/CT) scanner, which is characterized by a large-bore and time-of-flight (TOF) function, in accordance with the NEMA NU-2 2012 standard and version 2.0 of the Japanese guideline for oncology fluorodeoxyglucose PET/CT data acquisition protocol. Spatial resolution, sensitivity, count rate characteristic, scatter fraction, energy resolution, TOF timing resolution, and image quality were evaluated according to the NEMA NU-2 2012 standard. Phantom experiments were performed using 18 F-solution and an IEC body phantom of the type described in the NEMA NU-2 2012 standard. The minimum scanning time required for the detection of a 10-mm hot sphere with a 4:1 target-to-background ratio, the phantom noise equivalent count (NEC phantom ), % background variability (N 10mm ), % contrast (Q H,10mm ), and recovery coefficient (RC) were calculated according to the Japanese guideline. The measured spatial resolution ranged from 4.5- to 5-mm full width at half maximum (FWHM). The sensitivity and scatter fraction were 3.8 cps/kBq and 37.3%, respectively. The peak noise-equivalent count rate was 70 kcps in the presence of 29.6 kBq mL -1 in the phantom. The system energy resolution was 12.4% and the TOF timing resolution was 411 ps at FWHM. Minimum scanning times of 2, 7, 6, and 2 min per bed position, respectively, are recommended for visual score, noise-equivalent count (NEC) phantom , N 10mm , and the Q H,10mm to N 10mm ratio (QNR) by the Japanese guideline. The RC of a 10-mm-diameter sphere was 0.49, which exceeded the minimum recommended value. The Celesteion large-bore PET/CT system had low sensitivity and NEC, but good spatial and time resolution when compared to other PET/CT scanners. The QNR met the recommended values of the Japanese guideline even at 2 min. The Celesteion is therefore thought to provide acceptable image quality with 2 min/bed position acquisition, which is the most common scan protocol in Japan.

  2. Simulations of a micro-PET system based on liquid xenon

    NASA Astrophysics Data System (ADS)

    Miceli, A.; Glister, J.; Andreyev, A.; Bryman, D.; Kurchaninov, L.; Lu, P.; Muennich, A.; Retiere, F.; Sossi, V.

    2012-03-01

    The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of large area avalanche photodiodes for the measurement of ionization charge and scintillation light. A key feature of the LXePET system is the ability to identify individual photon interactions with high energy resolution and high spatial resolution in three dimensions and determine the correct interaction sequence using Compton reconstruction algorithms. The simulated LXePET imaging performance was evaluated by computing the noise equivalent count rate, the sensitivity and point spread function for a point source according to the NEMA-NU4 standard. The image quality was studied with a micro-Derenzo phantom. Results of these simulation studies included noise equivalent count rate peaking at 1326 kcps at 188 MBq (705 kcps at 184 MBq) for an energy window of 450-600 keV and a coincidence window of 1 ns for mouse (rat) phantoms. The absolute sensitivity at the center of the field of view was 12.6%. Radial, tangential and axial resolutions of 22Na point sources reconstructed with a list-mode maximum likelihood expectation maximization algorithm were ⩽0.8 mm (full-width at half-maximum) throughout the field of view. Hot-rod inserts of <0.8 mm diameter were resolvable in the transaxial image of a micro-Derenzo phantom. The simulations show that a LXe system would provide new capabilities for significantly enhancing PET images.

  3. Historical gridded reconstruction of potential evapotranspiration for the UK

    NASA Astrophysics Data System (ADS)

    Tanguy, Maliko; Prudhomme, Christel; Smith, Katie; Hannaford, Jamie

    2018-06-01

    Potential evapotranspiration (PET) is a necessary input data for most hydrological models and is often needed at a daily time step. An accurate estimation of PET requires many input climate variables which are, in most cases, not available prior to the 1960s for the UK, nor indeed most parts of the world. Therefore, when applying hydrological models to earlier periods, modellers have to rely on PET estimations derived from simplified methods. Given that only monthly observed temperature data is readily available for the late 19th and early 20th century at a national scale for the UK, the objective of this work was to derive the best possible UK-wide gridded PET dataset from the limited data available.To that end, firstly, a combination of (i) seven temperature-based PET equations, (ii) four different calibration approaches and (iii) seven input temperature data were evaluated. For this evaluation, a gridded daily PET product based on the physically based Penman-Monteith equation (the CHESS PET dataset) was used, the rationale being that this provides a reliable ground truth PET dataset for evaluation purposes, given that no directly observed, distributed PET datasets exist. The performance of the models was also compared to a naïve method, which is defined as the simplest possible estimation of PET in the absence of any available climate data. The naïve method used in this study is the CHESS PET daily long-term average (the period from 1961 to 1990 was chosen), or CHESS-PET daily climatology.The analysis revealed that the type of calibration and the input temperature dataset had only a minor effect on the accuracy of the PET estimations at catchment scale. From the seven equations tested, only the calibrated version of the McGuinness-Bordne equation was able to outperform the naïve method and was therefore used to derive the gridded, reconstructed dataset. The equation was calibrated using 43 catchments across Great Britain.The dataset produced is a 5 km gridded PET dataset for the period 1891 to 2015, using the Met Office 5 km monthly gridded temperature data available for that time period as input data for the PET equation. The dataset includes daily and monthly PET grids and is complemented with a suite of mapped performance metrics to help users assess the quality of the data spatially.This dataset is expected to be particularly valuable as input to hydrological models for any catchment in the UK. The data can be accessed at https://doi.org/10.5285/17b9c4f7-1c30-4b6f-b2fe-f7780159939c.

  4. Do TSH, FT3, and FT4 Impact BAT Visualization of Clinical FDG-PET/CT Images?

    PubMed Central

    Nagamachi, Shigeki; Mizutani, Youichi; Terada, Tamasa; Kiyohara, Syogo; Wakamatsu, Hideyuki; Fujita, Seigo; Higashi, Tatsuya; Yoshinaga, Keiichiro; Saga, Tsuneo; Hirai, Toshinori

    2018-01-01

    Objective We retrospectively analyzed activated BAT visualization on FDG-PET/CT in patients with various conditions and TH levels to clarify the relationships between visualization of BAT on FDG-PET/CT and the effect of TH. Methods Patients who underwent clinical FDG-PET/CT were reviewed and we categorized patients into 5 groups: (i) thyroid hormone withdrawal (THW) group; (ii) recombinant human thyrotropin (rhTSH) group; (iii) hypothyroidism group; (iv) hyperthyroidism group; and (v) BAT group. A total of sixty-two FDG-PET/CT imaging studies in fifty-nine patients were performed. To compare each group, gender; age; body weight; serum TSH, FT3, and FT4 levels; and outside temperature were evaluated. Results No significant visualization of BAT was noted in any of the images in the THW, rhTSH, hypothyroidism, and hyperthyroidism groups. All patients in the BAT group were in a euthyroid state. When the BAT-negative and BAT-positive patient groups were compared, it was noted that the minimum and maximum temperature on the day of the PET study and maximum temperature of the one day before the PET study were significantly lower in BAT-positive group than in all those of other groups. Conclusions Elevated TSH condition before RIT, hyperthyroidism, or hypothyroidism did not significantly impact BAT visualization of clinical FDG-PET/CT images. PMID:29666563

  5. Simultaneous PET and Multispectral 3-Dimensional Fluorescence Optical Tomography Imaging System

    PubMed Central

    Li, Changqing; Yang, Yongfeng; Mitchell, Gregory S.; Cherry, Simon R.

    2015-01-01

    Integrated PET and 3-dimensional (3D) fluorescence optical tomography (FOT) imaging has unique and attractive features for in vivo molecular imaging applications. We have designed, built, and evaluated a simultaneous PET and 3D FOT system. The design of the FOT system is compatible with many existing small-animal PET scanners. Methods The 3D FOT system comprises a novel conical mirror that is used to view the whole-body surface of a mouse with an electron-multiplying charge-coupled device camera when a collimated laser beam is projected on the mouse to stimulate fluorescence. The diffusion equation was used to model the propagation of optical photons inside the mouse body, and 3D fluorescence images were reconstructed iteratively from the fluorescence intensity measurements measured from the surface of the mouse. Insertion of the conical mirror into the gantry of a small-animal PET scanner allowed simultaneous PET and 3D FOT imaging. Results The mutual interactions between PET and 3D FOT were evaluated experimentally. PET has negligible effects on 3D FOT performance. The inserted conical mirror introduces a reduction in the sensitivity and noise-equivalent count rate of the PET system and increases the scatter fraction. PET–FOT phantom experiments were performed. An in vivo experiment using both PET and FOT was also performed. Conclusion Phantom and in vivo experiments demonstrate the feasibility of simultaneous PET and 3D FOT imaging. The first in vivo simultaneous PET–FOT results are reported. PMID:21810591

  6. Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project

    NASA Astrophysics Data System (ADS)

    Paolozzi, L.; Bandi, Y.; Benoit, M.; Cardarelli, R.; Débieux, S.; Forshaw, D.; Hayakawa, D.; Iacobucci, G.; Kaynak, M.; Miucci, A.; Nessi, M.; Ratib, O.; Ripiccini, E.; Rücker, H.; Valerio, P.; Weber, M.

    2018-04-01

    The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e‑ RMS and a pulse rise time of less than 2 ns , in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to have a detection efficiency greater than 99% and, although in the absence of the post-processing, a time resolution of approximately 200 ps .

  7. Estimation of potential evapotranspiration from extraterrestrial radiation, air temperature and humidity to assess future climate change effects on the vegetation of the Northern Great Plains, USA

    USGS Publications Warehouse

    King, David A.; Bachelet, Dominique M.; Symstad, Amy J.; Ferschweiler, Ken; Hobbins, Michael

    2014-01-01

    The potential evapotranspiration (PET) that would occur with unlimited plant access to water is a central driver of simulated plant growth in many ecological models. PET is influenced by solar and longwave radiation, temperature, wind speed, and humidity, but it is often modeled as a function of temperature alone. This approach can cause biases in projections of future climate impacts in part because it confounds the effects of warming due to increased greenhouse gases with that which would be caused by increased radiation from the sun. We developed an algorithm for linking PET to extraterrestrial solar radiation (incoming top-of atmosphere solar radiation), as well as temperature and atmospheric water vapor pressure, and incorporated this algorithm into the dynamic global vegetation model MC1. We tested the new algorithm for the Northern Great Plains, USA, whose remaining grasslands are threatened by continuing woody encroachment. Both the new and the standard temperature-dependent MC1 algorithm adequately simulated current PET, as compared to the more rigorous PenPan model of Rotstayn et al. (2006). However, compared to the standard algorithm, the new algorithm projected a much more gradual increase in PET over the 21st century for three contrasting future climates. This difference led to lower simulated drought effects and hence greater woody encroachment with the new algorithm, illustrating the importance of more rigorous calculations of PET in ecological models dealing with climate change.

  8. Safety assessment of modified terephthalate polymers as used in cosmetics.

    PubMed

    Becker, Lillian C; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan

    2014-01-01

    The safety of 6 modified terephthalate polymers as cosmetic ingredients was assessed. These ingredients mostly function as exfoliants, bulking agents, hair fixatives, and viscosity-increasing agents-nonaqueous. Polyethylene terephthalate (PET) is used in leave-on products up to 100% and in rinse-off products up to 2%. The Cosmetic Ingredient Review Expert Panel (Panel) considered that the PET used in cosmetics is chemically equivalent to that used in medical devices. The Panel determined that the Food and Drug Administration's determination of safety of PET in several medical devices, which included human and animal safety data, can be used as the basis for the determination of safety of PET and related polymers used in cosmetics. Use studies of cosmetic eye products that contain PET demonstrated no ocular irritation or dermal sensitization. The Panel concluded that modified terephthalate polymers were safe as cosmetic ingredients in the practices of use and concentration described in this safety assessment. © The Author(s) 2014.

  9. Conventional and thermophilic aerobic treatability of high strength oily pet food wastewater using membrane-coupled bioreactors.

    PubMed

    Kurian, R; Acharya, C; Nakhla, G; Bassi, A

    2005-11-01

    Although thermophilic treatment systems have recently gained considerable interest, limited information exists on the comparative performances of membrane-coupled bioreactors (MBR) at thermophilic and conventional conditions. In this study aerobic MBRs operating at room temperature (20 degrees C) and at lower thermophilic range (45 degrees C) were investigated for the treatment of dissolved air flotation (DAF) pretreated pet food wastewater. The particular wastewater is characterized by oil and grease (O & G) concentrations as high as 6 g/L, COD of 51 g/L, BOD of 16 g/L and volatile fatty acid (VFA) of 8.3 g/L. The performances of the two systems in terms of COD, BOD and O & G removal at varying hydraulic retention time (HRT) are compared. COD removal efficiencies in the thermophilic MBR varied from 75% to 98% and remained constant at 94% in the conventional MBR. The O & G removal efficiencies were 66-86% and 98% in the thermophilic and conventional MBR, respectively. Interestingly, high concentrations of VFA were recorded, equivalent to 50-73% of total COD, in the thermophilic MBR effluent. The observed yield in the thermophilic MBR was 40% of that observed in the conventional MBR.

  10. Summertime Minimum Streamflow Elasticity to Antecendent Winter Precipitation, Peak Snow Water Equivalent and Summertime Evaporative Demand in the Western US Maritime Mountains

    NASA Astrophysics Data System (ADS)

    Schaperow, J.; Cooper, M. G.; Cooley, S. W.; Alam, S.; Smith, L. C.; Lettenmaier, D. P.

    2017-12-01

    As climate regimes shift, streamflows and our ability to predict them will change, as well. Elasticity of summer minimum streamflow is estimated for 138 unimpaired headwater river basins across the maritime western US mountains to better understand how climatologic variables and geologic characteristics interact to determine the response of summer low flows to winter precipitation (PPT), spring snow water equivalent (SWE), and summertime potential evapotranspiration (PET). Elasticities are calculated using log log linear regression, and linear reservoir storage coefficients are used to represent basin geology. Storage coefficients are estimated using baseflow recession analysis. On average, SWE, PET, and PPT explain about 1/3 of the summertime low flow variance. Snow-dominated basins with long timescales of baseflow recession are least sensitive to changes in SWE, PPT, and PET, while rainfall-dominated, faster draining basins are most sensitive. There are also implications for the predictability of summer low flows. The R2 between streamflow and SWE drops from 0.62 to 0.47 from snow-dominated to rain-dominated basins, while there is no corresponding increase in R2 between streamflow and PPT.

  11. Finite Element Modeling of Reheat Stretch Blow Molding of PET

    NASA Astrophysics Data System (ADS)

    Krishnan, Dwarak; Dupaix, Rebecca B.

    2004-06-01

    Poly (ethylene terephthalate) or PET is a polymer used as a packaging material for consumer products such as beverages, food or other liquids, and in other applications including drawn fibers and stretched films. Key features that make it widely used are its transparency, dimensional stability, gas impermeability, impact resistance, and high stiffness and strength in certain preferential directions. These commercially useful properties arise from the fact that PET crystallizes upon deformation above the glass transition temperature. Additionally, this strain-induced crystallization causes the deformation behavior of PET to be highly sensitive to processing conditions. It is thus crucial for engineers to be able to predict its performance at various process temperatures, strain rates and strain states so as to optimize the manufacturing process. In addressing these issues; a finite element analysis of the reheat blow molding process with PET has been carried out using ABAQUS. The simulation employed a constitutive model for PET developed by Dupaix and Boyce et al.. The model includes the combined effects of molecular orientation and strain-induced crystallization on strain hardening when the material is deformed above the glass transition temperature. The simulated bottles were also compared with actual blow molded bottles to evaluate the validity of the simulation.

  12. Micrometeorological simulations to predict the impacts of heat mitigation strategies on pedestrian thermal comfort in a Los Angeles neighborhood

    NASA Astrophysics Data System (ADS)

    Taleghani, Mohammad; Sailor, David; Ban-Weiss, George A.

    2016-02-01

    The urban heat island impacts the thermal comfort of pedestrians in cities. In this paper, the effects of four heat mitigation strategies on micrometeorology and the thermal comfort of pedestrians were simulated for a neighborhood in eastern Los Angeles County. The strategies investigated include solar reflective ‘cool roofs’, vegetative ‘green roofs’, solar reflective ‘cool pavements’, and increased street-level trees. A series of micrometeorological simulations for an extreme heat day were carried out assuming widespread adoption of each mitigation strategy. Comparing each simulation to the control simulation assuming current land cover for the neighborhood showed that additional street-trees and cool pavements reduced 1.5 m air temperature, while cool and green roofs mostly provided cooling at heights above pedestrian level. However, cool pavements increased reflected sunlight from the ground to pedestrians at a set of unshaded receptor locations. This reflected radiation intensified the mean radiant temperature and consequently increased physiological equivalent temperature (PET) by 2.2 °C during the day, reducing the thermal comfort of pedestrians. At another set of receptor locations that were on average 5 m from roadways and underneath preexisting tree cover, cool pavements caused significant reductions in surface air temperatures and small changes in mean radiant temperature during the day, leading to decreases in PET of 1.1 °C, and consequent improvements in thermal comfort. For improving thermal comfort of pedestrians during the afternoon in unshaded locations, adding street trees was found to be the most effective strategy. However, afternoon thermal comfort improvements in already shaded locations adjacent to streets were most significant for cool pavements. Green and cool roofs showed the lowest impact on the thermal comfort of pedestrians since they modify the energy balance at roof level, above the height of pedestrians.

  13. Outdoor comfort study in Rio de Janeiro: site-related context effects on reported thermal sensation

    NASA Astrophysics Data System (ADS)

    Krüger, E.; Drach, P.; Broede, P.

    2017-03-01

    Aimed at climate-responsive urban design for tropical areas, the paper attempts to answer the question whether the site-related context affects in some way the perceptual assessment of the microclimate by users of outdoor spaces. Our hypothesis was that visual cues resulting from urban design are important components of the outdoor thermal perception. Monitoring was carried out alongside the administration of standard comfort questionnaires throughout summer periods in 2012-2015 in pedestrian areas of downtown Rio de Janeiro (22° 54 10 S, 43° 12 27 W), Brazil. Campaigns took place at different points, pre-defined in respect of urban geometry attributes. For the measurements, a Davis Vantage Pro2 weather station was employed to which a gray globe thermometer was attached. Two thermal indices were used for assessing the overall meteorological conditions and comfort levels in the outdoor locations: physiological equivalent temperature (PET) and universal thermal climate index (UTCI). Our results suggest that thermal sensation in Rio depends to a large extent on the thermal environment as described by air temperature, PET, or UTCI, and that urban geometry (expressed by the sky-view factor (SVF)) may modify this relationship with increased building density associated to warmer sensation votes under moderate heat stress conditions. This relationship however reverses under strong heat stress with warmer sensations in less obstructed locations, and disappears completely under still higher heat stress, where meteorological conditions, and not the site's SVF, will drive thermal sensation.

  14. Outdoor comfort study in Rio de Janeiro: site-related context effects on reported thermal sensation.

    PubMed

    Krüger, E; Drach, P; Broede, P

    2017-03-01

    Aimed at climate-responsive urban design for tropical areas, the paper attempts to answer the question whether the site-related context affects in some way the perceptual assessment of the microclimate by users of outdoor spaces. Our hypothesis was that visual cues resulting from urban design are important components of the outdoor thermal perception. Monitoring was carried out alongside the administration of standard comfort questionnaires throughout summer periods in 2012-2015 in pedestrian areas of downtown Rio de Janeiro (22° 54 10 S, 43° 12 27 W), Brazil. Campaigns took place at different points, pre-defined in respect of urban geometry attributes. For the measurements, a Davis Vantage Pro2 weather station was employed to which a gray globe thermometer was attached. Two thermal indices were used for assessing the overall meteorological conditions and comfort levels in the outdoor locations: physiological equivalent temperature (PET) and universal thermal climate index (UTCI). Our results suggest that thermal sensation in Rio depends to a large extent on the thermal environment as described by air temperature, PET, or UTCI, and that urban geometry (expressed by the sky-view factor (SVF)) may modify this relationship with increased building density associated to warmer sensation votes under moderate heat stress conditions. This relationship however reverses under strong heat stress with warmer sensations in less obstructed locations, and disappears completely under still higher heat stress, where meteorological conditions, and not the site's SVF, will drive thermal sensation.

  15. Monte Carlo simulation of Ray-Scan 64 PET system and performance evaluation using GATE toolkit

    NASA Astrophysics Data System (ADS)

    Li, Suying; Zhang, Qiushi; Vuletic, Ivan; Xie, Zhaoheng; Yang, Kun; Ren, Qiushi

    2017-02-01

    In this study, we aimed to develop a GATE model for the simulation of Ray-Scan 64 PET scanner and model its performance characteristics. A detailed implementation of system geometry and physical process were included in the simulation model. Then we modeled the performance characteristics of Ray-Scan 64 PET system for the first time, based on National Electrical Manufacturers Association (NEMA) NU-2 2007 protocols and validated the model against experimental measurement, including spatial resolution, sensitivity, counting rates and noise equivalent count rate (NECR). Moreover, an accurate dead time module was investigated to simulate the counting rate performance. Overall results showed reasonable agreement between simulation and experimental data. The validation results showed the reliability and feasibility of the GATE model to evaluate major performance of Ray-Scan 64 PET system. It provided a useful tool for a wide range of research applications.

  16. Sensitivity of potential evapotranspiration and simulated flow to varying meteorological inputs, Salt Creek watershed, DuPage County, Illinois

    USGS Publications Warehouse

    Whitbeck, David E.

    2006-01-01

    The Lamoreux Potential Evapotranspiration (LXPET) Program computes potential evapotranspiration (PET) using inputs from four different meteorological sources: temperature, dewpoint, wind speed, and solar radiation. PET and the same four meteorological inputs are used with precipitation data in the Hydrological Simulation Program-Fortran (HSPF) to simulate streamflow in the Salt Creek watershed, DuPage County, Illinois. Streamflows from HSPF are routed with the Full Equations (FEQ) model to determine water-surface elevations. Consequently, variations in meteorological inputs have potential to propagate through many calculations. Sensitivity of PET to variation was simulated by increasing the meteorological input values by 20, 40, and 60 percent and evaluating the change in the calculated PET. Increases in temperatures produced the greatest percent changes, followed by increases in solar radiation, dewpoint, and then wind speed. Additional sensitivity of PET was considered for shifts in input temperatures and dewpoints by absolute differences of ?10, ?20, and ?30 degrees Fahrenheit (degF). Again, changes in input temperatures produced the greatest differences in PET. Sensitivity of streamflow simulated by HSPF was evaluated for 20-percent increases in meteorological inputs. These simulations showed that increases in temperature produced the greatest change in flow. Finally, peak water-surface elevations for nine storm events were compared among unmodified meteorological inputs and inputs with values predicted 6, 24, and 48 hours preceding the simulated peak. Results of this study can be applied to determine how errors specific to a hydrologic system will affect computations of system streamflow and water-surface elevations.

  17. Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards.

    PubMed

    Sato, K; Shidahara, M; Watabe, H; Watanuki, S; Ishikawa, Y; Arakawa, Y; Nai, Y H; Furumoto, S; Tashiro, M; Shoji, T; Yanai, K; Gonda, K

    2016-01-21

    The aim of this study was to evaluate the performance of ClairvivoPET using NEMA NU4 standards. The ClairvivoPET incorporates a LYSO dual depth-of-interaction detector system with 151 mm axial field of view (FOV). Spatial resolution, sensitivity, counting rate capabilities, and image quality were evaluated using NEMA NU4-2008 standards. Normal mouse imaging was also performed for 10 min after intravenous injection of (18)F(-)-NaF. Data were compared with 19 other preclinical PET scanners. Spatial resolution measured using full width at half maximum on FBP-ramp reconstructed images was 2.16 mm at radial offset 5 mm of the axial centre FOV. The maximum absolute sensitivity for a point source at the FOV centre was 8.72%. Peak noise equivalent counting rate (NECR) was 415 kcps at 14.6 MBq ml(-1). The uniformity with the image-quality phantom was 4.62%. Spillover ratios in the images of air and water filled chambers were 0.19 and 0.06, respectively. Our results were comparable with the 19 other preclinical PET scanners based on NEMA NU4 standards, with excellent sensitivity because of the large FOV. The ClairvivoPET with iterative reconstruction algorithm also provided sufficient visualization of the mouse spine. The high sensitivity and resolution of the ClairvivoPET scanner provided high quality images for preclinical studies.

  18. Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards

    NASA Astrophysics Data System (ADS)

    Sato, K.; Shidahara, M.; Watabe, H.; Watanuki, S.; Ishikawa, Y.; Arakawa, Y.; Nai, YH; Furumoto, S.; Tashiro, M.; Shoji, T.; Yanai, K.; Gonda, K.

    2016-01-01

    The aim of this study was to evaluate the performance of ClairvivoPET using NEMA NU4 standards. The ClairvivoPET incorporates a LYSO dual depth-of-interaction detector system with 151 mm axial field of view (FOV). Spatial resolution, sensitivity, counting rate capabilities, and image quality were evaluated using NEMA NU4-2008 standards. Normal mouse imaging was also performed for 10min after intravenous injection of 18F(-)-NaF. Data were compared with 19 other preclinical PET scanners. Spatial resolution measured using full width at half maximum on FBP-ramp reconstructed images was 2.16 mm at radial offset 5 mm of the axial centre FOV. The maximum absolute sensitivity for a point source at the FOV centre was 8.72%. Peak noise equivalent counting rate (NECR) was 415kcps at 14.6MBq ml-1. The uniformity with the image-quality phantom was 4.62%. Spillover ratios in the images of air and water filled chambers were 0.19 and 0.06, respectively. Our results were comparable with the 19 other preclinical PET scanners based on NEMA NU4 standards, with excellent sensitivity because of the large FOV. The ClairvivoPET with iterative reconstruction algorithm also provided sufficient visualization of the mouse spine. The high sensitivity and resolution of the ClairvivoPET scanner provided high quality images for preclinical studies.

  19. Preparation of ZnO nanorods on conductive PET-ITO-Ag fibers

    NASA Astrophysics Data System (ADS)

    Li, Yiwen; Ji, Shuai; Chen, Yuanyu; Zhang, Hong; Gong, Yumei; Guo, Jing

    2016-12-01

    We studied the vertical ZnO nanorods grown on conductive conventional polyethylene terephthalate (PET) fibers which are prepared by electroless silver depositing on tin-doped indium oxide (ITO) coated PET fibers through an efficient and low-cost green approach. The PET fibers were firstly functionalized with a layer of ITO gel synthesized through a sol-gel process at rather low temperature, simply by immersing the fibers into ITO sol for several minutes followed by gelation at 120 °C. Once the ITO gel layer surface was activated by SnCl2, a continuous, uniform, and compact layer of silver was carried out on the surface of the PET-ITO fibers through electroless plating operation at room temperature. The as-prepared PET-ITO-Ag fibers had good electrical conductivity, with surface resistivity as low as 0.23 mΩ cm. The overall procedure is simple, efficient, nontoxic, and controllable. The conductive PET-ITO-Ag fiber was used successfully as a flexible basal material to plant vertical ZnO nanorods through controlling the seeding and growth processes. The morphology of the PET-ITO, PET-ITO-Ag, and PET-ITO-Ag-ZnO fibers were observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Undergone the whole process, although the tensile strength of the fiber decreased slightly, they may still exert their applications in flexible electronic such as photovoltaic and piezoelectric devices.

  20. Towards tracer dose reduction in PET studies: Simulation of dose reduction by retrospective randomized undersampling of list-mode data.

    PubMed

    Gatidis, Sergios; Würslin, Christian; Seith, Ferdinand; Schäfer, Jürgen F; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schmidt, Holger

    2016-01-01

    Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose-reduced datasets based on clinical (18)F-FDG PET data demonstrated the clinical applicability of the proposed data. Simulation of PET tracer dose reduction is possible with retrospective undersampling of list-mode data. Resulting simulated low-dose images have equivalent characteristics with PET images actually measured at lower doses and can be used to derive optimal tracer dose regimes.

  1. Improving the low temperature dyeability of polyethylene terephthalate fabric with dispersive dyes by atmospheric pressure plasma discharge

    NASA Astrophysics Data System (ADS)

    Elabid, Amel E. A.; Zhang, Jie; Shi, Jianjun; Guo, Ying; Ding, Ke; Zhang, Jing

    2016-07-01

    Polyethylene terephthalate (PET) fiber and textile is one of the largest synthetic polymer commodity in the world. The great energy consumption and pollution caused by the high temperature and pressure dyeing of PET fibers and fabrics with disperse dyes has been caused concern these years. In this study, an atmospheric pressure plasma with fine and uniform filament discharge operated at 20 kHz has been used to improve the low temperature dyeability of PET fabric at 95 °C with three cation disperse dyes: Red 73, Blue 183 and Yellow 211. The dyes uptake percentage of the treated PET fabrics was observed to increase as twice as much of untreated fabric. The color strength rate was increased more than 20%. The reducing of the water contact angle and the raising of the capillary height of treated PET fabric strip indicate its hydrophilicity improvement. Scanning electron microscope (SEM) results display nano to micro size of etching pits appeared uniformly on the fiber surface of the treated PET. Simultaneously, X-ray photoelectron spectroscopy (XPS) analysis indicates an increase of the oxygen content in the surface caused by the introduction of polar groups such as Cdbnd O and COOH. The rough surface with improved polar oxygen groups showed hydrophilicity and affinity to C.I. dispersive dyes and is believed to be caused by the strong and very fine filament discharge appearing randomly at one place at an instant but evenly at many places at a longer period. This increases the diffusion and absorption of the C.I. disperse dyes on the PET fiber surface, which improve its low temperature dyeability.

  2. Harmonizing multiple methods for reconstructing historical potential and reference evapotranspiration

    USGS Publications Warehouse

    Belaineh, Getachew; Sumner, David; Carter, Edward; Clapp, David

    2013-01-01

    Potential evapotranspiration (PET) and reference evapotranspiration (RET) data are usually critical components of hydrologic analysis. Many different equations are available to estimate PET and RET. Most of these equations, such as the Priestley-Taylor and Penman- Monteith methods, rely on detailed meteorological data collected at ground-based weather stations. Few weather stations collect enough data to estimate PET or RET using one of the more complex evapotranspiration equations. Currently, satellite data integrated with ground meteorological data are used with one of these evapotranspiration equations to accurately estimate PET and RET. However, earlier than the last few decades, historical reconstructions of PET and RET needed for many hydrologic analyses are limited by the paucity of satellite data and of some types of ground data. Air temperature stands out as the most generally available meteorological ground data type over the last century. Temperature-based approaches used with readily available historical temperature data offer the potential for long period-of-record PET and RET historical reconstructions. A challenge is the inconsistency between the more accurate, but more data intensive, methods appropriate for more recent periods and the less accurate, but less data intensive, methods appropriate to the more distant past. In this study, multiple methods are harmonized in a seamless reconstruction of historical PET and RET by quantifying and eliminating the biases of the simple Hargreaves-Samani method relative to the more complex and accurate Priestley-Taylor and Penman-Monteith methods. This harmonization process is used to generate long-term, internally consistent, spatiotemporal databases of PET and RET.

  3. Assessing the ability of potential evapotranspiration models in capturing dynamics of evaporative demand across various biomes and climatic regimes with ChinaFLUX measurements

    NASA Astrophysics Data System (ADS)

    Zheng, Han; Yu, Guirui; Wang, Qiufeng; Zhu, Xianjin; Yan, Junhua; Wang, Huimin; Shi, Peili; Zhao, Fenghua; Li, Yingnian; Zhao, Liang; Zhang, Junhui; Wang, Yanfen

    2017-08-01

    Estimates of atmospheric evaporative demand have been widely required for a variety of hydrological analyses, with potential evapotranspiration (PET) being an important measure representing evaporative demand of actual vegetated surfaces under given metrological conditions. In this study, we assessed the ability of various PET models in capturing long-term (typically 2003-2011) dynamics of evaporative demand at eight ecosystems across various biomes and climatic regimes in China. Prior to assessing PET dynamics, we first examined the reasonability of fourteen PET models in representing the magnitudes of evaporative demand using eddy-covariance actual evapotranspiration (AET) as an indicator. Results showed that the robustness of the fourteen PET models differed somewhat across the sites, and only three PET models could produce reasonable magnitudes of evaporative demand (i.e., PET ≥ AET on average) for all eight sites, including the: (i) Penman; (ii) Priestly-Taylor and (iii) Linacre models. Then, we assessed the ability of these three PET models in capturing dynamics of evaporative demand by comparing the annual and seasonal trends in PET against the equivalent trends in AET and precipitation (P) for particular sites. Results indicated that nearly all the three PET models could faithfully reproduce the dynamics in evaporative demand for the energy-limited conditions at both annual and seasonal scales, while only the Penman and Linacre models could represent dynamics in evaporative demand for the water-limited conditions. However, the Linacre model was unable to reproduce the seasonal switches between water- and energy-limited states for some sites. Our findings demonstrated that the choice of PET models would be essential for the evaporative demand analyses and other related hydrological analyses at different temporal and spatial scales.

  4. SU-G-IeP4-07: Feasibility of Low Dose 18FDG PET in Pediatric Oncology Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Binzel, K; Hall, NC

    Purpose: To evaluate and demonstrate the feasibility of low dose FDG PET in pediatric oncology patients using virtual dose reduction as well as true patients PET/CT scans. Methods: Wholebody 18F-FDG PET/CT of 39 clinical pediatric patients (0.16±0.06MBq/kg) were scanned on a Gemini TF 64 system at 75±5 min post FDG injection using 3min/bed. Based on the 180s/bed listmode PET data, subsets of total counts in 120s, 90s, 60s, 30s and 15s per bed position were extracted for PET reconstruction to simulate lower dose PET at 2/3th, 1/2th, 1/3th, 1/6th and 1/12th dose levels. PET/CT scans of Jaszczak PET phantom withmore » 6 hot hollow spheres varying with sizes and contrast ratios were performed (real PET versus simulated PET) to validate the methodology of virtual dose PET simulation. Region of interests (ROIs) were placed on lesions and normal anatomical tissues with quantitative and qualitative assessment performed. Significant lower FDG dose PET/CT of 5 research adolescents were scanned to validate the proposal and low dose PET feasibility. Results: Although all lesions are visible on the 1/12th dose PET, overall PET image quality appears to be influenced in a multi-factorial way. 30%–60% dose reduction from current standard of care FDG PET is recommended to maintain equivalent quality and PET quantification. An optimized BMI-based FDG administration is recommended (from 1.1±0.5 mCi for BMI < 18.5 to 4.8±1.5 mCi for BMI > 30). A linear lowest “Dose-BMI” relationship is given. SUVs from 1/12th to full dose PETs were identified as consistent (R2 = 1.08, 0.99, 1.01, 1.00 and 0.98). No significant variances of count density, SUV and SNR were found across certain dose ranges (p<0.01). Conclusion: Pediatric PET/CT can be performed using current time-of-flight systems at substantially lower PET doses (30–60%) than the standard of care PET/CT without compromising qualitative and quantitative image quality in clinical.« less

  5. Development of high shrinkage polyethylene terephthalate (PET) shape memory polymer tendons for concrete crack closure

    NASA Astrophysics Data System (ADS)

    Teall, Oliver; Pilegis, Martins; Sweeney, John; Gough, Tim; Thompson, Glen; Jefferson, Anthony; Lark, Robert; Gardner, Diane

    2017-04-01

    The shrinkage force exerted by restrained shape memory polymers (SMPs) can potentially be used to close cracks in structural concrete. This paper describes the physical processing and experimental work undertaken to develop high shrinkage die-drawn polyethylene terephthalate (PET) SMP tendons for use within a crack closure system. The extrusion and die-drawing procedure used to manufacture a series of PET tendon samples is described. The results from a set of restrained shrinkage tests, undertaken at differing activation temperatures, are also presented along with the mechanical properties of the most promising samples. The stress developed within the tendons is found to be related to the activation temperature, the cross-sectional area and to the draw rate used during manufacture. Comparisons with commercially-available PET strip samples used in previous research are made, demonstrating an increase in restrained shrinkage stress by a factor of two for manufactured PET filament samples.

  6. Long-term perceptions of outdoor thermal environments in an elementary school in a hot-humid climate

    NASA Astrophysics Data System (ADS)

    Shih, Wen-Mei; Lin, Tzu-Ping; Tan, Ning-Xin; Liu, Mu-Hsien

    2017-09-01

    Previous studies on thermal comfort in school environments have focused more on indoor thermal environments than outdoor ones, thus providing a limited understanding of occupants' long-term thermal perceptions. Taiwan is located in a subtropical region, where it can be stiflingly hot outside in summer. This highlights the need to ensure proper thermal comfort on campus. In the present study, thermal environment parameters were measured and collected in several outdoor spaces of an elementary school in southern Taiwan. In addition, a questionnaire was used to explore occupants' long-term thermal perceptions of these spaces. During summer months, the physiological equivalent temperature (PET) of these outdoor spaces in over 60% of the daytime in summer between 10 a.m. and 4 p.m. was higher than 38 °C PET, indicating high heat stress. The results of occupants' long-term perceptions of the thermal comfort of these spaces suggested that dissatisfaction with thermal comfort was associated more with solar radiation than with wind speed. Finally, this study simulated a campus environment where more trees are planted and compared the thermal comfort indices before and after the simulation. The results indicated that this solution contributed to a decrease in the PET of these environments, thereby alleviating high heat stress. This study can inform the improvement of microclimates and thermal comfort during campus layout planning. Planting trees judiciously across a campus increases outdoor shades and creates outdoor spaces that are more comfortable and adaptable to hot weather conditions, thereby ensuring frequent use of these spaces.

  7. Thermal and tensile properties of alumina filled PET nanocomposites

    NASA Astrophysics Data System (ADS)

    Nikam, Pravin N.; Deshpande, Vineeta D.

    2018-05-01

    In the present investigation, nanocomposites of poly(ethylene terephathalate)(PET) with different content (0 to 5 wt.%) of alumina nanoparticles (n-Al2O3) were prepared by melt-extrusion technique. Morphological characterization of samples was examined by transmission electron microscopy (TEM). Morphological analysis revealed that degree of dispersion of alumina nanoparticles (ANPs) was increased at lower content (i.e. upto 2 wt.%), which observed by TEM. Thermal and tensile measurements were carried out using and differential scanning calorimetry (DSC) and universal testing machine (UTM). The thermal analysis showed that the glass transition termperature (Tg), melting temperature (Tm), crystallization temperature (Tc) of PET/alumina nanocomposites (PNCs) were higher than neat PET (PET0). The heat enthalpy (ΔHm) of crystallization for PNCs was increased compared to PET0, which indicates that degree of crystallinity of PNCs also increased compared to PET0. The half-time (t0.5) of crystallization of PNCs were decreased compared to PET0 which indicates that the incorporation of ANPs nucleate the PET molecular chains and allowing the easily crystallization during nonisothermal process. The tensile analysis revealed that the tensile elastic modulus (i.e. Young's modulus) of PNCs increased almost linearly with increasing the content of ANPs while tensile elongation at break decreased nonlinearly. The tensile strength of PNCs increased with a 1 wt.% of ANPs whereas the higher content of ANPs decreased the tensile strength.

  8. Variability of tropical days over Greece within the second half of the twentieth century

    NASA Astrophysics Data System (ADS)

    Nastos, P. T.; Matzarakis, A. P.

    2008-06-01

    Tropical days (TD) are defined as the days with a maximum air temperature greater than 30.0 °C. It is clear that the study of TD includes also the absolute maximum temperatures, which are of great interest for the description of a region’s climate. These days are considered as very hot, and they particularly are of great importance not only for bioclimatology and applied sciences, but also for the individuals who are sensitive in the heat-stress. The regime of the TD in Greece is the focus of this study. The aim is to demonstrate their changes from decade to decade, for the time period 1960-2000. For this study, the Annual Number of Tropical Days (ANTD) recorded by each of the 26 meteorological stations of National Meteorological Service, which are uniformly distributed in the Hellenic peninsula, was calculated and analysed. In terms of quantifying the conditions in a humanbiometeorological manner, the thermal index Physiological Equivalent Temperature (PET) and the consecutive days for Athens have been included in this study. The trends of the TD for each station were analysed through the Mann-Kendall technique, while the spatial distribution per decade reveals the regions with change (increase or decrease) in the ANTD during the examined period. Two characteristic periods of change for the ANTD appear in the majority of the meteorological stations in Greece. The first period (1955-1976) is determined by a negative trend, which is statistically significant (c.l. 95%), for adequate stations. In the period between 1976 and 2000, the increase in the ANTD and the maximum temperature exceed the corresponding maximum that appeared in the beginning of the 1950s for several of the examined meteorological stations. The human-biometeorological analysis shows that the consecutive days of PET > 35 °C have had a positive trend in the last two decades of the last century.

  9. PET-CMR in heart failure - synergistic or redundant imaging?

    PubMed

    Quail, Michael A; Sinusas, Albert J

    2017-07-01

    Imaging in heart failure (HF) provides data for diagnosis, prognosis and disease monitoring. Both MRI and nuclear imaging techniques have been successfully used for this purpose in HF. Positron Emission Tomography-Cardiac Magnetic Resonance (PET-CMR) is an example of a new multimodality diagnostic imaging technique with potential applications in HF. The threshold for adopting a new diagnostic tool to clinical practice must necessarily be high, lest they exacerbate costs without improving care. New modalities must demonstrate clinical superiority, or at least equivalence, combined with another important advantage, such as lower cost or improved patient safety. The purpose of this review is to outline the current status of multimodality PET-CMR with regard to HF applications, and determine whether the clinical utility of this new technology justifies the cost.

  10. Performance modeling of a wearable brain PET (BET) camera

    NASA Astrophysics Data System (ADS)

    Schmidtlein, C. R.; Turner, J. N.; Thompson, M. O.; Mandal, K. C.; Häggström, I.; Zhang, J.; Humm, J. L.; Feiglin, D. H.; Krol, A.

    2016-03-01

    Purpose: To explore, by means of analytical and Monte Carlo modeling, performance of a novel lightweight and low-cost wearable helmet-shaped Brain PET (BET) camera based on thin-film digital Geiger Avalanche Photo Diode (dGAPD) with LSO and LaBr3 scintillators for imaging in vivo human brain processes for freely moving and acting subjects responding to various stimuli in any environment. Methods: We performed analytical and Monte Carlo modeling PET performance of a spherical cap BET device and cylindrical brain PET (CYL) device, both with 25 cm diameter and the same total mass of LSO scintillator. Total mass of LSO in both the BET and CYL systems is about 32 kg for a 25 mm thick scintillator, and 13 kg for 10 mm thick scintillator (assuming an LSO density of 7.3 g/ml). We also investigated a similar system using an LaBr3 scintillator corresponding to 22 kg and 9 kg for the 25 mm and 10 mm thick systems (assuming an LaBr3 density of 5.08 g/ml). In addition, we considered a clinical whole body (WB) LSO PET/CT scanner with 82 cm ring diameter and 15.8 cm axial length to represent a reference system. BET consisted of distributed Autonomous Detector Arrays (ADAs) integrated into Intelligent Autonomous Detector Blocks (IADBs). The ADA comprised of an array of small LYSO scintillator volumes (voxels with base a×a: 1.0 <= a <= 2.0 mm and length c: 3.0 <= c <= 6.0 mm) with 5-65 μm thick reflective layers on its five sides and sixth side optically coupled to the matching array of dGAPDs and processing electronics with total thickness of 50 μm. Simulated energy resolution was 10.8% and 3.3% for LSO and LaBr3 respectively and the coincidence window was set at 2 ns. The brain was simulated as a sphere of uniform F-18 activity with diameter of 10 cm embedded in a center of water sphere with diameter of 10 cm. Results: Analytical and Monte Carlo models showed similar results for lower energy window values (458 keV versus 445 keV for LSO, and 492 keV versus 485 keV for LaBr3), and for the relative performance of system sensitivity. Monte Carlo results further showed that the BET geometry had >50% better noise equivalent count (NEC) performance relative to the CYL geometry, and >1100% better performance than a WB geometry for 25 mm thick LSO and LaBr3. For 10 mm thick LaBr3 equivalent mass systems LSO (7 mm thick) performed ~40% higher NEC than LaBr3. Analytic and Monte Carlo simulations also showed that 1×1×3 mm scintillator crystals can achieve ~1.2 mm FWHM spatial resolution. Conclusions: This study shows that a spherical cap brain PET system can provide improved NEC while preserving spatial resolution when compared to an equivalent dedicated cylindrical PET brain camera and shows greatly improved PET performance relative to a conventional whole body PET/CT. In addition, our simulations show that LSO will generally outperform LaBr3 for NEC unless the timing resolution for LaBr3 is considerably smaller than presently used for LSO, i.e. well below 300 ps.

  11. Preparation and dyeing of super hydrophilic polyethylene terephthalate fabric

    NASA Astrophysics Data System (ADS)

    Zheng, D. D.; Zhou, J. F.; Xu, F.; Zhang, F. X.; Zhang, G. X.

    2016-07-01

    In this study, the dyeing properties of PET fabrics modified with sulfuric acid was investigated using disperse red E-4B and disperse blue 2BLNG-L at high temperature and high pressure. The results revealed that the sulfuric acid modification improved the K/S value of dyeing PET fabrics, and the modified PET fabric could be dyed uniformly. The a, b, C, L and H of modified PET fabric were almost the same as that of original PET fabric. The water contact angles were still 0o after 10s, indicating that the hydrophilic property of modified PET fabrics still kept excellent. The wash fastness of dyed PET fabrics after modification was generally good.

  12. Regional climate model data used within the SWURVE project - 1: projected changes in seasonal patterns and estimation of PET

    NASA Astrophysics Data System (ADS)

    Ekström, M.; Jones, P. D.; Fowler, H. J.; Lenderink, G.; Buishand, T. A.; Conway, D.

    2007-04-01

    Climate data for studies within the SWURVE (Sustainable Water: Uncertainty, Risk and Vulnerability in Europe) project, assessing the risk posed by future climatic change to various hydrological and hydraulic systems were obtained from the regional climate model HadRM3H, developed at the Hadley Centre of the UK Met Office. This paper gives some background to HadRM3H; it also presents anomaly maps of the projected future changes in European temperature, rainfall and potential evapotranspiration (PET, estimated using a variant of the Penman formula). The future simulations of temperature and rainfall, following the SRES A2 emissions scenario, suggest that most of Europe will experience warming in all seasons, with heavier precipitation in winter in much of western Europe (except for central and northern parts of the Scandinavian mountains) and drier summers in most parts of western and central Europe (except for the north-west and the eastern part of the Baltic Sea). Particularly large temperature anomalies (>6°C) are projected for north-east Europe in winter and for southern Europe, Asia Minor and parts of Russia in summer. The projected PET displayed very large increases in summer for a region extending from southern France to Russia. The unrealistically large values could be the result of an enhanced hydrological cycle in HadRM3H, affecting several of the input parameters to the PET calculation. To avoid problems with hydrological modelling schemes, PET was re-calculated, using empirical relationships derived from observational values of temperature and PET.

  13. Comparison of DWI and 18F-FDG PET/CT for assessing preoperative N-staging in gastric cancer: evidence from a meta-analysis.

    PubMed

    Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo

    2017-10-13

    The diagnostic values of diffusion weighted imaging (DWI) and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73-0.85), 0.69 (0.61-0.77), and 0.81 (0.77-0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39-0.64), 0.88 (0.61-0.97), and 0.66 (0.62-0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18 F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18 F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18 F-FDG PET/CT had limited utility for preoperative N-staging.

  14. Metabolic impact of partial volume correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment.

    PubMed

    Stefano, A; Gallivanone, F; Messa, C; Gilardi, M C; Gastiglioni, I

    2014-12-01

    The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated for each lesion, with and without PVC. The accuracy, reproducibility, clinical feasibility and the metabolic impact on treatment response of the considered PVC method was evaluated. The PVC method was found clinically feasible in bone lesions, with an accuracy of 93% for lesion sphere-equivalent diameter >1 cm. Applying PVC, average SUV values increased, from 7% up to 154% considering both PET-I and PET-II studies, proving the need of the correction. As main finding, PVC modified the therapy response classification in 6 cases according to EORTC 1999 classification and in 5 cases according to PERCIST 1.0 classification. PVC has an important metabolic impact on the assessment of tumor response to treatment by [18F]FDG PET-CT oncological studies.

  15. Quantitative assessment of the physical potential of proton beam range verification with PET/CT.

    PubMed

    Knopf, A; Parodi, K; Paganetti, H; Cascio, E; Bonab, A; Bortfeld, T

    2008-08-07

    A recent clinical pilot study demonstrated the feasibility of offline PET/CT range verification for proton therapy treatments. In vivo PET measurements are challenged by blood perfusion, variations of tissue compositions, patient motion and image co-registration uncertainties. Besides these biological and treatment specific factors, the accuracy of the method is constrained by the underlying physical processes. This phantom study distinguishes physical factors from other factors, assessing the reproducibility, consistency and sensitivity of the PET/CT range verification method. A spread-out Bragg-peak (SOBP) proton field was delivered to a phantom consisting of poly-methyl methacrylate (PMMA), lung and bone equivalent material slabs. PET data were acquired in listmode at a commercial PET/CT scanner available within 10 min walking distance from the proton therapy unit. The measured PET activity distributions were compared to simulations of the PET signal based on Geant4 and FLUKA Monte Carlo (MC) codes. To test the reproducibility of the measured PET signal, data from two independent measurements at the same geometrical position in the phantom were compared. Furthermore, activation depth profiles within identical material arrangements but at different positions within the irradiation field were compared to test the consistency of the measured PET signal. Finally, activation depth profiles through air/lung, air/bone and lung/bone interfaces parallel as well as at 6 degrees to the beam direction were studied to investigate the sensitivity of the PET/CT range verification method. The reproducibility and the consistency of the measured PET signal were found to be of the same order of magnitude. They determine the physical accuracy of the PET measurement to be about 1 mm. However, range discrepancies up to 2.6 mm between two measurements and range variations up to 2.6 mm within one measurement were found at the beam edge and at the edge of the field of view (FOV) of the PET scanner. PET/CT range verification was found to be able to detect small range modifications in the presence of complex tissue inhomogeneities. This study indicates the physical potential of the PET/CT verification method to detect the full-range characteristic of the delivered dose in the patient.

  16. Quantitative assessment of the physical potential of proton beam range verification with PET/CT

    NASA Astrophysics Data System (ADS)

    Knopf, A.; Parodi, K.; Paganetti, H.; Cascio, E.; Bonab, A.; Bortfeld, T.

    2008-08-01

    A recent clinical pilot study demonstrated the feasibility of offline PET/CT range verification for proton therapy treatments. In vivo PET measurements are challenged by blood perfusion, variations of tissue compositions, patient motion and image co-registration uncertainties. Besides these biological and treatment specific factors, the accuracy of the method is constrained by the underlying physical processes. This phantom study distinguishes physical factors from other factors, assessing the reproducibility, consistency and sensitivity of the PET/CT range verification method. A spread-out Bragg-peak (SOBP) proton field was delivered to a phantom consisting of poly-methyl methacrylate (PMMA), lung and bone equivalent material slabs. PET data were acquired in listmode at a commercial PET/CT scanner available within 10 min walking distance from the proton therapy unit. The measured PET activity distributions were compared to simulations of the PET signal based on Geant4 and FLUKA Monte Carlo (MC) codes. To test the reproducibility of the measured PET signal, data from two independent measurements at the same geometrical position in the phantom were compared. Furthermore, activation depth profiles within identical material arrangements but at different positions within the irradiation field were compared to test the consistency of the measured PET signal. Finally, activation depth profiles through air/lung, air/bone and lung/bone interfaces parallel as well as at 6° to the beam direction were studied to investigate the sensitivity of the PET/CT range verification method. The reproducibility and the consistency of the measured PET signal were found to be of the same order of magnitude. They determine the physical accuracy of the PET measurement to be about 1 mm. However, range discrepancies up to 2.6 mm between two measurements and range variations up to 2.6 mm within one measurement were found at the beam edge and at the edge of the field of view (FOV) of the PET scanner. PET/CT range verification was found to be able to detect small range modifications in the presence of complex tissue inhomogeneities. This study indicates the physical potential of the PET/CT verification method to detect the full-range characteristic of the delivered dose in the patient.

  17. Ambient Dose Equivalent measured at the Instituto Nacional de Cancerología Department of Nuclear Medicine

    NASA Astrophysics Data System (ADS)

    Ávila, O.; Torres-Ulloa, C. L.; Medina, L. A.; Trujillo-Zamudio, F. E.; de Buen, I. Gamboa; Buenfil, A. E.; Brandan, M. E.

    2010-12-01

    Ambient dose equivalent values were determined in several sites at the Instituto Nacional de Cancerología, Departmento de Medicina Nuclear, using TLD-100 and TLD-900 thermoluminescent dosemeters. Additionally, ambient dose equivalent was measured at a corridor outside the hospitalization room for patients treated with 137Cs brachytherapy. Dosemeter calibration was performed at the Instituto Nacional de Investigaciones Nucleares, Laboratorio de Metrología, to known 137Cs gamma radiation air kerma. Radionuclides considered for this study are 131I, 18F, 67Ga, 99mTc, 111In, 201Tl and 137Cs, with main gamma energies between 93 and 662 keV. Dosemeters were placed during a five month period in the nuclear medicine rooms (containing gamma-cameras), injection corridor, patient waiting areas, PET/CT study room, hot lab, waste storage room and corridors next to the hospitalization rooms for patients treated with 131I and 137Cs. High dose values were found at the waste storage room, outside corridor of 137Cs brachytherapy patients and PET/CT area. Ambient dose equivalent rate obtained for the 137Cs brachytherapy corridor is equal to (18.51±0.02)×10-3 mSv/h. Sites with minimum doses are the gamma camera rooms, having ambient dose equivalent rates equal to (0.05±0.03)×10-3 mSv/h. Recommendations have been given to the Department authorities so that further actions are taken to reduce doses at high dose sites in order to comply with the ALARA principle (as low as reasonably achievable).

  18. Evaluation of PeneloPET Simulations of Biograph PET/CT Scanners

    NASA Astrophysics Data System (ADS)

    Abushab, K. M.; Herraiz, J. L.; Vicente, E.; Cal-González, J.; España, S.; Vaquero, J. J.; Jakoby, B. W.; Udías, J. M.

    2016-06-01

    Monte Carlo (MC) simulations are widely used in positron emission tomography (PET) for optimizing detector design, acquisition protocols, and evaluating corrections and reconstruction methods. PeneloPET is a MC code based on PENELOPE, for PET simulations which considers detector geometry, acquisition electronics and materials, and source definitions. While PeneloPET has been successfully employed and validated with small animal PET scanners, it required a proper validation with clinical PET scanners including time-of-flight (TOF) information. For this purpose, we chose the family of Biograph PET/CT scanners: the Biograph True-Point (B-TP), Biograph True-Point with TrueV (B-TPTV) and the Biograph mCT. They have similar block detectors and electronics, but a different number of rings and configuration. Some effective parameters of the simulations, such as the dead-time and the size of the reflectors in the detectors, were adjusted to reproduce the sensitivity and noise equivalent count (NEC) rate of the B-TPTV scanner. These parameters were then used to make predictions of experimental results such as sensitivity, NEC rate, spatial resolution, and scatter fraction (SF), from all the Biograph scanners and some variations of them (energy windows and additional rings of detectors). Predictions agree with the measured values for the three scanners, within 7% (sensitivity and NEC rate) and 5% (SF). The resolution obtained for the B-TPTV is slightly better (10%) than the experimental values. In conclusion, we have shown that PeneloPET is suitable for simulating and investigating clinical systems with good accuracy and short computational time, though some effort tuning of a few parameters of the scanners modeled may be needed in case that the full details of the scanners studied are not available.

  19. Antioxidant activity and emulsion-stabilizing effect of pectic enzyme treated pectin in soy protein isolate-stabilized oil/water emulsion.

    PubMed

    Huang, Ping-Hsiu; Lu, Hao-Te; Wang, Yuh-Tai; Wu, Ming-Chang

    2011-09-14

    The antioxidant activity of pectic enzyme treated pectin (PET-pectin) prepared from citrus pectin by enzymatic hydrolysis and its potential use as a stabilizer and an antioxidant for soy protein isolate (SPI)-stabilized oil in water (O/W) emulsion were investigated. Trolox equivalent antioxidant capacity (TEAC) was found to be positively associated with molecular weight (M(w)) of PET-pectin and negatively associated with degree of esterification (DE) of PET-pectin. PET-pectin (1 kDa and 11.6% DE) prepared from citrus pectin after 24 h of hydrolysis by commercial pectic enzyme produced by Aspergillus niger expressed higher α,α-diphenyl-β-picrylhydrazyl (DPPH) radical scavenging activity, TEAC, and reducing power than untreated citrus pectin (353 kDa and 60% DE). The addition of PET-pectin could increase both emulsifying activity (EA) and emulsion stability (ES) of SPI-stabilized O/W emulsion. When the SPI-stabilized lipid droplet was coated with the mixture of PET-pectin and pectin, the EA and ES of the emulsion were improved more than they were when the lipid droplet was coated with either pectin or PET-pectin alone. The amount of secondary oxidation products (thiobarbituric acid reactive substances) produced in the emulsion prepared with the mixture of SPI and PET-pectin was less than the amount produced in the emulsion prepared with either SPI or SPI/pectin. These results suggest that PET-pectin has an emulsion-stabilizing effect and lipid oxidation inhibition ability on SPI-stabilized emulsion. Therefore, PET-pectin can be used as a stabilizer as well as an antioxidant in plant origin in SPI-stabilized O/W emulsion and thus prolong the shelf life of food emulsion.

  20. Validation of a Monte Carlo simulation of the Inveon PET scanner using GATE

    NASA Astrophysics Data System (ADS)

    Lu, Lijun; Zhang, Houjin; Bian, Zhaoying; Ma, Jianhua; Feng, Qiangjin; Chen, Wufan

    2016-08-01

    The purpose of this study is to validate the application of GATE (Geant4 Application for Tomographic Emission) Monte Carlo simulation toolkit in order to model the performance characteristics of Siemens Inveon small animal PET system. The simulation results were validated against experimental/published data in accordance with the NEMA NU-4 2008 protocol for standardized evaluation of spatial resolution, sensitivity, scatter fraction (SF) and noise equivalent counting rate (NECR) of a preclinical PET system. An agreement of less than 18% was obtained between the radial, tangential and axial spatial resolutions of the simulated and experimental results. The simulated peak NECR of mouse-size phantom agreed with the experimental result, while for the rat-size phantom simulated value was higher than experimental result. The simulated and experimental SFs of mouse- and rat- size phantom both reached an agreement of less than 2%. It has been shown the feasibility of our GATE model to accurately simulate, within certain limits, all major performance characteristics of Inveon PET system.

  1. Toward VIP-PIX: A Low Noise Readout ASIC for Pixelated CdTe Gamma-Ray Detectors for Use in the Next Generation of PET Scanners.

    PubMed

    Macias-Montero, Jose-Gabriel; Sarraj, Maher; Chmeissani, Mokhtar; Puigdengoles, Carles; Lorenzo, Gianluca De; Martínez, Ricardo

    2013-08-01

    VIP-PIX will be a low noise and low power pixel readout electronics with digital output for pixelated Cadmium Telluride (CdTe) detectors. The proposed pixel will be part of a 2D pixel-array detector for various types of nuclear medicine imaging devices such as positron-emission tomography (PET) scanners, Compton gamma cameras, and positron-emission mammography (PEM) scanners. Each pixel will include a SAR ADC that provides the energy deposited with 10-bit resolution. Simultaneously, the self-triggered pixel which will be connected to a global time-to-digital converter (TDC) with 1 ns resolution will provide the event's time stamp. The analog part of the readout chain and the ADC have been fabricated with TSMC 0.25 μ m mixed-signal CMOS technology and characterized with an external test pulse. The power consumption of these parts is 200 μ W from a 2.5 V supply. It offers 4 switchable gains from ±10 mV/fC to ±40 mV/fC and an input charge dynamic range of up to ±70 fC for the minimum gain for both polarities. Based on noise measurements, the expected equivalent noise charge (ENC) is 65 e - RMS at room temperature.

  2. Characteristics of a multichannel low-noise front-end ASIC for CZT-based small animal PET imaging

    NASA Astrophysics Data System (ADS)

    Gao, W.; Liu, H.; Gan, B.; Hu, Y.

    2014-05-01

    In this paper, we present the design and characteristics of a novel low-noise front-end readout application-specific integrated circuit dedicated to CdZnTe (CZT) detectors for a small animal PET imaging system. A low-noise readout method based on the charge integration and the delayed peak detection is proposed. An eight-channel front-end readout prototype chip is designed and implemented in a 0.35 μm CMOS process. The die size is 2.3 mm ×2.3 mm. The prototype chip is tested in different methods including electronic test, energy spectrum test and irradiation test. The input range of the ASIC is from 2000e- to 180,000e-, reflecting the energy of the gamma ray from 11.2 keV to 1 MeV. The gain of the readout channel is 65 mV/fC at the shaping time of 1 μs. The best test result of the equivalent noise charge (ENC) is 58.9 e- at zero farad plus 5.4 e- per picofarad. The nonlinearity and the crosstalk are less than 3% and less than 2%, respectively, at the room temperature. The static power dissipation is about 3 mW/channel.

  3. Development of a large-sample catchment-scale hydro-meteorological, land cover and physical dataset for Chile

    NASA Astrophysics Data System (ADS)

    Alvarez-Garreton, C. D.; Mendoza, P. A.; Zambrano-Bigiarini, M.; Galleguillos, M. H.; Boisier, J. P.; Lara, A.; Cortés, G.; Garreaud, R.; McPhee, J. P.; Addor, N.; Puelma, C.

    2017-12-01

    We provide the first catchment-based hydrometeorological, vegetation and physical data set over 531 catchments in Chile (17.8 S - 55.0 S). We compiled publicly available streamflow records at daily time steps for the period 1980-2015, and generated basin-averaged time series of the following hydrometeorological variables: 1) daily precipitation coming from three different gridded sources (re-analysis and satellite-based); 2) daily maximum and minimum temperature; 3) 8-days potential evapotranspiration (PET) based on MODIS imagery and daily PET based on Hargreaves formula; and 4) daily snow water equivalent. Additionally, catchments are characterized by their main physical (area, mean elevation, mean slope) and land cover characteristics. We synthetized these datasets with several indices characterizing the spatial distribution of climatic, hydrological, topographic and vegetation attributes. The new catchment-based dataset is unprecedented in the region and provides information that can be used in a myriad of applications, including catchment classification and regionalization studies, impacts of different land cover types on catchment response, characterization of drought history and projections, climate change impacts on hydrological processes, etc. Derived practical applications include water management and allocation strategies, decision making and adaptation planning to climate change. This data set will be publicly available and we encourage the community to use it.

  4. In situ synthesis of TiO2/polyethylene terephthalate hybrid nanocomposites at low temperature

    NASA Astrophysics Data System (ADS)

    Peng, Xinyan; Ding, Enyong; Xue, Feng

    2012-06-01

    TiO2 nanoflowers were in situ grown on polyethylene terephthalate (PET) non-woven fabric by hydrolysis of TiCl4 in aqueous solution in the presence of nanocrystal cellulose grafted PET fabric (NCC-g-PET) at a low temperature of 70 °C. Nanocrystal cellulose (NCC) pre-grafted on PET fabric acted as hydrophilic substrate and morphology inducing agent to promote the nucleation and crystal growth of TiO2. Detailed information on the synthetic process was presented. The resulting samples were characterized using FE-SEM, EDS, ATR-IR, Raman microscopy, XRD and TG analysis. The photocatalytic activity of the samples was evaluated by the degradation of orange methyl under solar light. Characteristic results indicate that rutile TiO2 nanoflowers have grown abundantly on PET non-woven fabric, and the established hydrogen bonding strengthens the interfacial interaction between the inorganic particles and the polymeric substrates. The methyl orange decoloration test under natural solar light demonstrates that this TiO2/PET hybrid nanocomposites exhibit excellent self-cleaning performance which is expected to have a good potential for commercialization.

  5. Is ET often oversimplified in hydrologic models? Using long records to elucidate unaccounted for controls on ET

    NASA Astrophysics Data System (ADS)

    Kelleher, Christa A.; Shaw, Stephen B.

    2018-02-01

    Recent research has found that hydrologic modeling over decadal time periods often requires time variant model parameters. Most prior work has focused on assessing time variance in model parameters conceptualizing watershed features and functions. In this paper, we assess whether adding a time variant scalar to potential evapotranspiration (PET) can be used in place of time variant parameters. Using the HBV hydrologic model and four different simple but common PET methods (Hamon, Priestly-Taylor, Oudin, and Hargreaves), we simulated 60+ years of daily discharge on four rivers in New York state. Allowing all ten model parameters to vary in time achieved good model fits in terms of daily NSE and long-term water balance. However, allowing single model parameters to vary in time - including a scalar on PET - achieved nearly equivalent model fits across PET methods. Overall, varying a PET scalar in time is likely more physically consistent with known biophysical controls on PET as compared to varying parameters conceptualizing innate watershed properties related to soil properties such as wilting point and field capacity. This work suggests that the seeming need for time variance in innate watershed parameters may be due to overly simple evapotranspiration formulations that do not account for all factors controlling evapotranspiration over long time periods.

  6. Assessment of daytime outdoor comfort levels in and outside the urban area of Glasgow, UK.

    PubMed

    Krüger, Eduardo; Drach, Patricia; Emmanuel, Rohinton; Corbella, Oscar

    2013-07-01

    To understand thermal preferences and to define a preliminary outdoor comfort range for the local population of Glasgow, UK, an extensive series of measurements and surveys was carried out during 19 monitoring campaigns from winter through summer 2011 at six different monitoring points in pedestrian areas of downtown Glasgow. For data collection, a Davis Vantage Pro2 weather station equipped with temperature and humidity sensors, cup anemometer with wind vane, silicon pyranometer and globe thermometer was employed. Predictions of the outdoor thermal index PET (physiologically equivalent temperature) correlated closely to the actual thermal votes of respondents. Using concurrent measurements from a second Davis Vantage Pro2 weather station placed in a rural setting approximately 15 km from the urban area, comparisons were drawn with regard to daytime thermal comfort levels and urban-rural temperature differences (∆T(u-r)) for the various sites. The urban sites exhibited a consistent lower level of thermal discomfort during daytime. No discernible effect of urban form attributes in terms of the sky-view factor were observed on ∆Tu-r or on the relative difference of the adjusted predicted percentage of dissatisfied (PPD*).

  7. Grief following pet and human loss: Closeness is key.

    PubMed

    Eckerd, Lizabeth M; Barnett, James E; Jett-Dias, Latishia

    2016-01-01

    The authors compared grief severity and its predictors in two equivalent college student samples who had experienced the death of a pet (n = 211) or a person (n = 146) within the past 2 years. The human death sample reported higher grief severity, p < .01, but effect sizes were small (ds = .28-.30). For both samples, closeness to the deceased was overwhelmingly the strongest predictor of grief severity; other predictors generally dropped out with closeness added to the model. Results highlight the importance of including closeness to deceased in grief research, and its centrality in understanding grief counseling clients.

  8. Daytime variation in ambient temperature affects skin temperatures and blood pressure: Ambulatory winter/summer comparison in healthy young women.

    PubMed

    Martinez-Nicolas, Antonio; Meyer, Martin; Hunkler, Stefan; Madrid, Juan Antonio; Rol, Maria Angeles; Meyer, Andrea H; Schötzau, Andy; Orgül, Selim; Kräuchi, Kurt

    2015-10-01

    It is widely accepted that cold exposure increases peripheral vascular resistance and arterial blood pressure (BP) and, hence, increases cardiovascular risk primarily in the elderly. However, there is a lack of concomitantly longitudinal recordings at personal level of environmental temperature (PET) and cardiophysiological variables together with skin temperatures (STs, the “interface-variable” between the body core and ambient temperature). To investigate the intra-individual temporal relationships between PET, STs and BP 60 healthy young women (52 completed the entire study) were prospectively studied in a winter/summer design for 26 h under real life conditions. The main hypothesis was tested whether distal ST (Tdist)mediates the effect of PET-changes on mean arterial BP (MAP). Diurnal profiles of cardiophysiological variables (including BP), STs and PET were ambulatory recorded. Daytime variations between 0930 and 2030 h were analyzed in detail by intra-individual longitudinal path analysis. Additionally, time segments before, during and after outdoor exposure were separately analyzed. In both seasons short-term variations in PET were positively associated with short-term changes in Tdist (not proximal ST, Tprox) and negatively with those in MAP. However, long-term seasonal differences in daytime mean levels were observed in STs but not in BP leading to non-significant inter-individual correlation between STs and BP. Additionally, higher individual body mass index (BMI) was significantly associated with lower daytime mean levels of Tprox and higher MAP suggesting Tprox as potential mediator variable for the association of BMI with MAP. In healthy young women the thermoregulatory and BP-regulatory systems are closely linked with respect to short-term, but not long-term changes in PET. One hypothetical explanation could serve recent findings that thermogenesis in brown adipose tissue is activated in a cool environment, which could be responsible for the counter-regulation of cold induced increase of BP in winter leading to no seasonal differences in MAP. Our findings suggest that the assessment of diurnal patterns of STs and PET, in addition to the conventional ambulatory BP monitoring, might improve individual cardiovascular risk prediction.

  9. PET Imaging Stability Measurements During Simultaneous Pulsing of Aggressive MR Sequences on the SIGNA PET/MR System.

    PubMed

    Deller, Timothy W; Khalighi, Mohammad Mehdi; Jansen, Floris P; Glover, Gary H

    2018-01-01

    The recent introduction of simultaneous whole-body PET/MR scanners has enabled new research taking advantage of the complementary information obtainable with PET and MRI. One such application is kinetic modeling, which requires high levels of PET quantitative stability. To accomplish the required PET stability levels, the PET subsystem must be sufficiently isolated from the effects of MR activity. Performance measurements have previously been published, demonstrating sufficient PET stability in the presence of MR pulsing for typical clinical use; however, PET stability during radiofrequency (RF)-intensive and gradient-intensive sequences has not previously been evaluated for a clinical whole-body scanner. In this work, PET stability of the GE SIGNA PET/MR was examined during simultaneous scanning of aggressive MR pulse sequences. Methods: PET performance tests were acquired with MR idle and during simultaneous MR pulsing. Recent system improvements mitigating RF interference and gain variation were used. A fast recovery fast spin echo MR sequence was selected for high RF power, and an echo planar imaging sequence was selected for its high heat-inducing gradients. Measurements were performed to determine PET stability under varying MR conditions using the following metrics: sensitivity, scatter fraction, contrast recovery, uniformity, count rate performance, and image quantitation. A final PET quantitative stability assessment for simultaneous PET scanning during functional MRI studies was performed with a spiral in-and-out gradient echo sequence. Results: Quantitation stability of a 68 Ge flood phantom was demonstrated within 0.34%. Normalized sensitivity was stable during simultaneous scanning within 0.3%. Scatter fraction measured with a 68 Ge line source in the scatter phantom was stable within the range of 40.4%-40.6%. Contrast recovery and uniformity were comparable for PET images acquired simultaneously with multiple MR conditions. Peak noise equivalent count rate was 224 kcps at an effective activity concentration of 18.6 kBq/mL, and the count rate curves and scatter fraction curve were consistent for the alternating MR pulsing states. A final test demonstrated quantitative stability during a spiral functional MRI sequence. Conclusion: PET stability metrics demonstrated that PET quantitation was not affected during simultaneous aggressive MRI. This stability enables demanding applications such as kinetic modeling. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  10. New blackbody standard for the evaluation and calibration of tympanic ear thermometers at the NPL, United Kingdom

    NASA Astrophysics Data System (ADS)

    McEvoy, Helen C.; Simpson, Robert; Machin, Graham

    2004-04-01

    The use of infrared tympanic thermometers for monitoring patient health is widespread. However, studies into the performance of these thermometers have questioned their accuracy and repeatability. To give users confidence in these devices, and to provide credibility in the measurements, it is necessary for them to be tested using an accredited, standard blackbody source, with a calibration traceable to the International Temperature Scale of 1990 (ITS-90). To address this need the National Physical Laboratory (NPL), UK, has recently set up a primary ear thermometer calibration (PET-C) source for the evaluation and calibration of tympanic (ear) thermometers over the range from 15 °C to 45 °C. The overall uncertainty of the PET-C source is estimated to be +/- 0.04 °C at k = 2. The PET-C source meets the requirements of the European Standard EN 12470-5: 2003 Clinical thermometers. It consists of a high emissivity blackbody cavity immersed in a bath of stirred liquid. The temperature of the blackbody is determined using an ITS-90 calibrated platinum resistance thermometer inserted close to the rear of the cavity. The temperature stability and uniformity of the PET-C source was evaluated and its performance validated. This paper provides a description of the PET-C along with the results of the validation measurements. To further confirm the performance of the PET-C source it was compared to the standard ear thermometer calibration sources of the National Metrology Institute of Japan (NMIJ), Japan and the Physikalisch-Technische Bundesanstalt (PTB), Germany. The results of this comparison will also be briefly discussed. The PET-C source extends the capability for testing ear thermometers offered by the NPL body temperature fixed-point source, described previously. An update on the progress with the commercialisation of the fixed-point source will be given.

  11. The influence of thermal discomfort on the attention index of teenagers: an experimental evaluation

    NASA Astrophysics Data System (ADS)

    Mazon, Jordi

    2014-07-01

    In order to measure the effect on the attention of teenagers of thermal discomfort due to high temperature and humidity, two experiments were conducted in two different indoor conditions of temperature and humidity in non-air-conditioned classrooms. The participants were a heterogeneous group of 117 teenagers, aged 12 to 18 years, and the experiments reproduced the actual conditions of teaching in a classroom in the Mediterranean climate. In order to measure the attention index, a standard Toulouse-Pieron psychological test was performed on the 117 teenagers in these two conditions, and the Predicted Mean Vote (PMV), the physiologically Equivalent Temperature (PET), the Standard effective Temperature (SET*) and the Universal Thermal Climate Index (UTCI) indices were calculated to estimate the grade of discomfort using the RayMan Pro model. Conditions of greater discomfort decreased the attention index in the whole group, especially in those aged 12-14, among whom the attention index dropped by around 45 % when compared to comfortable conditions. However, teenage attention at ages 17 and 18 shows little variation in discomfort in respect to thermally comfortable conditions. In addition, the attention index for boys and girls shows the same variation in discomfort conditions. However, girls have a slightly higher attention index than boys in discomfort and thermal comfort experiments.

  12. Optimizing Street Canyon Orientation for Rajarhat Newtown, Kolkata, India

    NASA Astrophysics Data System (ADS)

    De, Bhaskar; Mukherjee, Mahua

    2017-12-01

    Air temperature in urban street canyons is increased due to the morphed urban geometry, increased surface area, decreased long wave radiation and evapo-transpiration, different thermo-physical properties of surface materials and anthropogenic heat which results in thermal discomfort. Outdoor thermal stress can be mitigated substantially by properly orienting the canyons. It is crucial for the urban planners and designers to orient street canyons optimally considering variable local climatic context. It is important especially for cities in warm humid climatic context as these cities receive higher insolation with higher relative humidity and low level macro wind flow. This paper examines influence of canyon orientation on outdoor thermal comfort and proposes the optimum canyon orientation for the Rajarhat Newtown, Kolkata - a city in warm humid climate zone. Different scenarios are generated with different orientations. Change in air temperature, wind speed, Mean Radiant Temperature (MRT) and Physiological Equivalent Temperature (PET) of different scenarios are compared to find out the optimum orientation by parametric simulation in ENVI_met. Analysing the simulation results it is observed that orientation angle between 30°-60° to north performs the best for the study area of the Rajarhat Newtown. The findings of this research will be helpful for the planners to orient the street canyons optimally for future development and extension of the Rajarhat Newtown, Kolkata.

  13. Comparison of kinetic and air temperatures in Budapest aiming applications in weather forecasting

    NASA Astrophysics Data System (ADS)

    Mika, Janos; Nemeth, Akos; Bela Olah, Andras; Dezso, Zsuzsanna

    2010-05-01

    Moderate Resolution Imaging Spectroradiometer (MODIS) based kinetic temperature data are compared with the surface air temperature data at the four weather stations in Budapest, Hun-gary. Dependence of these temperature characteristics on weather conditions, characterised by macrosynoptic types and by objective weather types, is in the focus of the study. Day- and night-time kinetic temperature series are used from the period 2001-2008. Four automatic stations are also used as the surface-based control variables. The four MODIS-pixels, covering one station, each, are the sites of our comparison. One of the four stations has strictly urban situation at the roof level in a strongly built-in region of Budapest. Another one, used as background rural station is at the east-west edge of the town with gar-dened environment. Two other stations are positioned near the river Danube at the northern and southern edges of Budapest, still under mezo-scale effect of the city. The number of elaborated hourly values is 4300-4400 above each pixel, depending on the cloudiness. At the four station automatic observations on air temperature, cloudiness (=0), relative humidity and wind-speed are observed in the hours of the MODIS observations. From these elements air temperature is used for comparison with the satellite-based kinetic temperature, and also as the main components of the Physiologically Equivalent Temperature (PET), de-rived to characterise usefulness of the kinetic temperature. Our first aim is to specify detailed relationship between the two temperatures consider-ing the seasonal and diurnal cycles and synoptic situation. This comparison is also performed by using the PET to establish which kind of temperature reminds this human bioclimatic in-dex better. If we could establish effective relationships with the synoptic situations (or weather types) we could use them in two further applications. The first one is the everyday forecasting of dangerous situations within the city on the days when the rural weather forecast claims about extreme temperature even at the rural sites. On summer hot days the weather-dependent UHI increases but on cold winter days decreases the risks on human health and technical equipments. The other scientific problem is whether the long-term season-dependent changes of the atmospheric circulation can modify the behaviour of the UHI even without fur-ther changes in the building in of the city. To answer this question the established relation-ships are combined with regional climate change projections of the circulation conditions.

  14. Optimization of oncological {sup 18}F-FDG PET/CT imaging based on a multiparameter analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menezes, Vinicius O., E-mail: vinicius@radtec.com.br; Machado, Marcos A. D.; Queiroz, Cleiton C.

    2016-02-15

    Purpose: This paper describes a method to achieve consistent clinical image quality in {sup 18}F-FDG scans accounting for patient habitus, dose regimen, image acquisition, and processing techniques. Methods: Oncological PET/CT scan data for 58 subjects were evaluated retrospectively to derive analytical curves that predict image quality. Patient noise equivalent count rate and coefficient of variation (CV) were used as metrics in their analysis. Optimized acquisition protocols were identified and prospectively applied to 179 subjects. Results: The adoption of different schemes for three body mass ranges (<60 kg, 60–90 kg, >90 kg) allows improved image quality with both point spread functionmore » and ordered-subsets expectation maximization-3D reconstruction methods. The application of this methodology showed that CV improved significantly (p < 0.0001) in clinical practice. Conclusions: Consistent oncological PET/CT image quality on a high-performance scanner was achieved from an analysis of the relations existing between dose regimen, patient habitus, acquisition, and processing techniques. The proposed methodology may be used by PET/CT centers to develop protocols to standardize PET/CT imaging procedures and achieve better patient management and cost-effective operations.« less

  15. Variability and trends in global drought

    USGS Publications Warehouse

    McCabe, Gregory J.; Wolock, David M.

    2015-01-01

    Monthly precipitation (P) and potential evapotranspiration (PET) from the CRUTS3.1 data set are used to compute monthly P minus PET (PMPE) for the land areas of the globe. The percent of the global land area with annual sums of PMPE less than zero are used as an index of global drought (%drought) for 1901 through 2009. Results indicate that for the past century %drought has not changed, even though global PET and temperature (T) have increased. Although annual global PET and T have increased, annual global P also has increased and has mitigated the effects of increased PET on %drought.

  16. 68Ga-THP-PSMA: A PET Imaging Agent for Prostate Cancer Offering Rapid, Room-Temperature, 1-Step Kit-Based Radiolabeling.

    PubMed

    Young, Jennifer D; Abbate, Vincenzo; Imberti, Cinzia; Meszaros, Levente K; Ma, Michelle T; Terry, Samantha Y A; Hider, Robert C; Mullen, Greg E; Blower, Philip J

    2017-08-01

    The clinical impact and accessibility of 68 Ga tracers for the prostate-specific membrane antigen (PSMA) and other targets would be greatly enhanced by the availability of a simple, 1-step kit-based labeling process. Radiopharmacy staff are accustomed to such procedures in the daily preparation of 99m Tc radiopharmaceuticals. Currently, chelating agents used in 68 Ga radiopharmaceuticals do not meet this ideal. The aim of this study was to develop and evaluate preclinically a 68 Ga radiotracer for imaging PSMA expression that could be radiolabeled simply by addition of 68 Ga generator eluate to a cold kit. Methods: A conjugate of a tris(hydroxypyridinone) (THP) chelator with the established urea-based PSMA inhibitor was synthesized and radiolabeled with 68 Ga by adding generator eluate directly to a vial containing the cold precursors THP-PSMA and sodium bicarbonate, with no further manipulation. It was analyzed after 5 min by instant thin-layer chromatography and high-performance liquid chromatography. The product was subjected to in vitro studies to determine PSMA affinity using PSMA-expressing DU145-PSMA cells, with their nonexpressing analog DU145 as a control. In vivo PET imaging and ex vivo biodistribution studies were performed in mice bearing xenografts of the same cell lines, comparing 68 Ga-THP-PSMA with 68 Ga-HBED-CC-PSMA. Results: Radiolabeling was complete (>95%) within 5 min at room temperature, showing a single radioactive species by high-performance liquid chromatography that was stable in human serum for more than 6 h and showed specific binding to PSMA-expressing cells (concentration giving 50% inhibition of 361 ± 60 nM). In vivo PET imaging showed specific uptake in PSMA-expressing tumors, reaching 5.6 ± 1.2 percentage injected dose per cubic centimeter at 40-60 min and rapid clearance from blood to kidney and bladder. The tumor uptake, biodistribution, and pharmacokinetics were not significantly different from those of 68 Ga-HBED-CC-PSMA except for reduced uptake in the spleen. Conclusion: 68 Ga-THP-PSMA has equivalent imaging properties but greatly simplified radiolabeling compared with other 68 Ga-PSMA conjugates. THP offers the prospect of rapid, simple, 1-step, room-temperature syringe-and-vial radiolabeling of 68 Ga radiopharmaceuticals. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  17. GATE Monte Carlo simulations for variations of an integrated PET/MR hybrid imaging system based on the Biograph mMR model

    NASA Astrophysics Data System (ADS)

    Aklan, B.; Jakoby, B. W.; Watson, C. C.; Braun, H.; Ritt, P.; Quick, H. H.

    2015-06-01

    A simulation toolkit, GATE (Geant4 Application for Tomographic Emission), was used to develop an accurate Monte Carlo (MC) simulation of a fully integrated 3T PET/MR hybrid imaging system (Siemens Biograph mMR). The PET/MR components of the Biograph mMR were simulated in order to allow a detailed study of variations of the system design on the PET performance, which are not easy to access and measure on a real PET/MR system. The 3T static magnetic field of the MR system was taken into account in all Monte Carlo simulations. The validation of the MC model was carried out against actual measurements performed on the PET/MR system by following the NEMA (National Electrical Manufacturers Association) NU 2-2007 standard. The comparison of simulated and experimental performance measurements included spatial resolution, sensitivity, scatter fraction, and count rate capability. The validated system model was then used for two different applications. The first application focused on investigating the effect of an extension of the PET field-of-view on the PET performance of the PET/MR system. The second application deals with simulating a modified system timing resolution and coincidence time window of the PET detector electronics in order to simulate time-of-flight (TOF) PET detection. A dedicated phantom was modeled to investigate the impact of TOF on overall PET image quality. Simulation results showed that the overall divergence between simulated and measured data was found to be less than 10%. Varying the detector geometry showed that the system sensitivity and noise equivalent count rate of the PET/MR system increased progressively with an increasing number of axial detector block rings, as to be expected. TOF-based PET reconstructions of the modeled phantom showed an improvement in signal-to-noise ratio and image contrast to the conventional non-TOF PET reconstructions. In conclusion, the validated MC simulation model of an integrated PET/MR system with an overall accuracy error of less than 10% can now be used for further MC simulation applications such as development of hardware components as well as for testing of new PET/MR software algorithms, such as assessment of point-spread function-based reconstruction algorithms.

  18. Evaluation of focus laterality in temporal lobe epilepsy: a quantitative study comparing double inversion-recovery MR imaging at 3T with FDG-PET.

    PubMed

    Morimoto, Emiko; Okada, Tomohisa; Kanagaki, Mitsunori; Yamamoto, Akira; Fushimi, Yasutaka; Matsumoto, Riki; Takaya, Shigetoshi; Ikeda, Akio; Kunieda, Takeharu; Kikuchi, Takayuki; Paul, Dominik; Miyamoto, Susumu; Takahashi, Ryosuke; Togashi, Kaori

    2013-12-01

    To quantitatively compare the diagnostic capability of double inversion-recovery (DIR) with F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) for detection of seizure focus laterality in temporal lobe epilepsy (TLE). This study was approved by the institutional review board, and written informed consent was obtained. Fifteen patients with TLE and 38 healthy volunteers were enrolled. All magnetic resonance (MR) images were acquired using a 3T-MRI system. Voxel-based analysis (VBA) was conducted for FDG-PET images and white matter segments of DIR images (DIR-WM) focused on the whole temporal lobe (TL) and the anterior part of the temporal lobe (ATL). Distribution of hypometabolic areas on FDG-PET and increased signal intensity areas on DIR-WM were evaluated, and their laterality was compared with clinically determined seizure focus laterality. Correct diagnostic rates of laterality were evaluated, and agreement between DIR-WM and FDG-PET was assessed using κ statistics. Increased signal intensity areas on DIR-WM were located at the vicinity of the hypometabolic areas on FDG-PET, especially in the ATL. Correct diagnostic rates of seizure focus laterality for DIR-WM (0.80 and 0.67 for the TL and the ATL, respectively) were slightly higher than those for FDG-PET (0.67 and 0.60 for the TL and the ATL, respectively). Agreement of laterality between DIR-WM and FDG-PET was substantial for the TL and almost perfect for the ATL (κ = 0.67 and 0.86, respectively). High agreement in localization between DIR-WM and FDG-PET and nearly equivalent detectability of them show us an additional role of MRI in TLE. Wiley Periodicals, Inc. © 2013 International League Against Epilepsy.

  19. Comparison of DWI and 18F-FDG PET/CT for assessing preoperative N-staging in gastric cancer: evidence from a meta-analysis

    PubMed Central

    Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo

    2017-01-01

    The diagnostic values of diffusion weighted imaging (DWI) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73–0.85), 0.69 (0.61–0.77), and 0.81 (0.77–0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39–0.64), 0.88 (0.61–0.97), and 0.66 (0.62–0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18F-FDG PET/CT had limited utility for preoperative N-staging. PMID:29137440

  20. 64Cu-DOTA-trastuzumab PET imaging in patients with HER2-positive breast cancer.

    PubMed

    Tamura, Kenji; Kurihara, Hiroaki; Yonemori, Kan; Tsuda, Hitoshi; Suzuki, Junko; Kono, Yuzuru; Honda, Natsuki; Kodaira, Makoto; Yamamoto, Harukaze; Yunokawa, Mayu; Shimizu, Chikako; Hasegawa, Koki; Kanayama, Yousuke; Nozaki, Satoshi; Kinoshita, Takayuki; Wada, Yasuhiro; Tazawa, Shusaku; Takahashi, Kazuhiro; Watanabe, Yasuyoshi; Fujiwara, Yasuhiro

    2013-11-01

    The purpose of this study was to determine the safety, distribution, internal dosimetry, and initial human epidermal growth factor receptor 2 (HER2)-positive tumor images of (64)Cu-DOTA-trastuzumab in humans. PET was performed on 6 patients with primary or metastatic HER2-positive breast cancer at 1, 24, and 48 h after injection of approximately 130 MBq of the probe (64)Cu-DOTA-trastuzumab. Radioactivity data were collected from the blood, urine, and normal-tissue samples of these 6 patients, and the multiorgan biodistribution and internal dosimetry of the probe were evaluated. Safety data were collected for all the patients after the administration of (64)Cu-DOTA-trastuzumab and during the 1-wk follow-up period. According to our results, the best timing for the assessment of (64)Cu-DOTA-trastuzumab uptake by the tumor was 48 h after injection. Radiation exposure during (64)Cu-DOTA-trastuzumab PET was equivalent to that during conventional (18)F-FDG PET. The radioactivity in the blood was high, but uptake of (64)Cu-DOTA-trastuzumab in normal tissues was low. In 2 patients, (64)Cu-DOTA-trastuzumab PET showed brain metastases, indicative of blood-brain barrier disruptions. In 3 patients, (64)Cu-DOTA-trastuzumab PET imaging also revealed primary breast tumors at the lesion sites initially identified by CT. The findings of this study indicated that (64)Cu-DOTA-trastuzumab PET is feasible for the identification of HER2-positive lesions in patients with primary and metastatic breast cancer. The dosimetry and pharmacologic safety results were acceptable at the dose required for adequate PET imaging.

  1. Dosage optimization in positron emission tomography: state-of-the-art methods and future prospects

    PubMed Central

    Karakatsanis, Nicolas A; Fokou, Eleni; Tsoumpas, Charalampos

    2015-01-01

    Positron emission tomography (PET) is widely used nowadays for tumor staging and therapy response in the clinic. However, average PET radiation exposure has increased due to higher PET utilization. This study aims to review state-of-the-art PET tracer dosage optimization methods after accounting for the effects of human body attenuation and scan protocol parameters on the counting rate. In particular, the relationship between the noise equivalent count rate (NECR) and the dosage (NECR-dosage curve) for a range of clinical PET systems and body attenuation sizes will be systematically studied to prospectively estimate the minimum dosage required for sufficiently high NECR. The optimization criterion can be determined either as a function of the peak of the NECR-dosage curve or as a fixed NECR score when NECR uniformity across a patient population is important. In addition, the systematic NECR assessments within a controllable environment of realistic simulations and phantom experiments can lead to a NECR-dosage response model, capable of predicting the optimal dosage for every individual PET scan. Unlike conventional guidelines suggesting considerably large dosage levels for obese patients, NECR-based optimization recommends: i) moderate dosage to achieve 90% of peak NECR for obese patients, ii) considerable dosage reduction for slimmer patients such that uniform NECR is attained across the patient population, and iii) prolongation of scans for PET/MR protocols, where longer PET acquisitions are affordable due to lengthy MR sequences, with motion compensation becoming important then. Finally, the need for continuous adaptation of dosage optimization to emerging technologies will be discussed. PMID:26550543

  2. Co-pyrolysis of rice straw and Polyethylene Terephthalate (PET) using a fixed bed drop type pyrolyzer

    NASA Astrophysics Data System (ADS)

    Izzatie, N. I.; Basha, M. H.; Uemura, Y.; Hashim, M. S. M.; Amin, N. A. M.; Hamid, M. F.

    2017-10-01

    In this work, co-pyrolysis of rice straw and polyethylene terephthalate (PET) was carried out at different temperatures (450,500,550, and 600°C) at ratio 1:1 by using fixed bed drop-type pyrolyzer. The purpose of this work is to determine the effect of pyrolysis temperature on the product yield. As the temperature increased, the pyrolysis oil increased until it reaches certain high temperature (600°C), the pyrolysis oil decreased as of more NCG were produced. The temperature 550°C is considered as the optimum pyrolysis temperature since it produced the highest amount of pyrolysis oil with 36 wt.%. In pyrolysis oil, the calorific value (13.98kJ/g) was low because of the presence of high water content (52.46 wt.%). Main chemicals group from pyrolysis oil were an aldehyde, ketones, acids, aromatics, and phenol and all compound have abundant of hydrogen and carbon were identified. Co-pyrolysis of rice straw and PET produced a higher amount of carbon oxides and recycling back the NCG could increase liquid and char yields.

  3. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

    PubMed

    Burger, C; Goerres, G; Schoenes, S; Buck, A; Lonn, A H R; Von Schulthess, G K

    2002-07-01

    The CT data acquired in combined PET/CT studies provide a fast and essentially noiseless source for the correction of photon attenuation in PET emission data. To this end, the CT values relating to attenuation of photons in the range of 40-140 keV must be transformed into linear attenuation coefficients at the PET energy of 511 keV. As attenuation depends on photon energy and the absorbing material, an accurate theoretical relation cannot be devised. The transformation implemented in the Discovery LS PET/CT scanner (GE Medical Systems, Milwaukee, Wis.) uses a bilinear function based on the attenuation of water and cortical bone at the CT and PET energies. The purpose of this study was to compare this transformation with experimental CT values and corresponding PET attenuation coefficients. In 14 patients, quantitative PET attenuation maps were calculated from germanium-68 transmission scans, and resolution-matched CT images were generated. A total of 114 volumes of interest were defined and the average PET attenuation coefficients and CT values measured. From the CT values the predicted PET attenuation coefficients were calculated using the bilinear transformation. When the transformation was based on the narrow-beam attenuation coefficient of water at 511 keV (0.096 cm(-1)), the predicted attenuation coefficients were higher in soft tissue than the measured values. This bias was reduced by replacing 0.096 cm(-1) in the transformation by the linear attenuation coefficient of 0.093 cm(-1) obtained from germanium-68 transmission scans. An analysis of the corrected emission activities shows that the resulting transformation is essentially equivalent to the transmission-based attenuation correction for human tissue. For non-human material, however, it may assign inaccurate attenuation coefficients which will also affect the correction in neighbouring tissue.

  4. Scatter Fraction, Count Rates, and Noise Equivalent Count Rate of a Single-Bed Position RPC TOF-PET System Assessed by Simulations Following the NEMA NU2-2001 Standards

    NASA Astrophysics Data System (ADS)

    Couceiro, Miguel; Crespo, Paulo; Marques, Rui F.; Fonte, Paulo

    2014-06-01

    Scatter Fraction (SF) and Noise Equivalent Count Rate (NECR) of a 2400 mm wide axial field-of-view Positron Emission Tomography (PET) system based on Resistive Plate Chamber (RPC) detectors with 300 ps Time Of Flight (TOF) resolution were studied by simulation using Geant4. The study followed the NEMA NU2-2001 standards, using the standard 700 mm long phantom and an axially extended one with 1800 mm, modeling the foreseeable use of this PET system. Data was processed based on the actual RPC readout, which requires a 0.2 μs non-paralyzable dead time for timing signals and a paralyzable dead time (τps) for position signals. For NECR, the best coincidence trigger consisted of a multiple time window coincidence sorter retaining single coincidence pairs (involving only two photons) and all possible coincidence pairs obtained from Multiple coincidences, keeping only those for which the direct TOF-reconstructed point falls inside a tight region surrounding the phantom. For the 700 mm phantom, the SF was 51.8% and, with τps = 3.0 μs, the peak NECR was 167 kcps at 7.6 kBq/cm3. Using τps = 1.0 μs the NECR was 349 kcps at 7.6 kBq/cm3, and no peak was found. For the 1800 mm phantom, the SF was slightly higher, and the NECR curves were identical to those obtained with the standard phantom, but shifted to lower activity concentrations. Although the higher SF, the values obtained for NECR allow concluding that the proposed scanner is expected to outperform current commercial PET systems.

  5. PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner.

    PubMed

    Omidvari, Negar; Cabello, Jorge; Topping, Geoffrey; Schneider, Florian R; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I

    2017-11-01

    MADPET4 is the first small animal PET insert with two layers of individually read out crystals in combination with silicon photomultiplier technology. It has a novel detector arrangement, in which all crystals face the center of field of view transaxially. In this work, the PET performance of MADPET4 was evaluated and compared to other preclinical PET scanners using the NEMA NU 4 measurements, followed by imaging a mouse-size hot-rod resolution phantom and two in vivo simultaneous PET/MRI scans in a 7 T MRI scanner. The insert had a peak sensitivity of 0.49%, using an energy threshold of 350 keV. A uniform transaxial resolution was obtained up to 15 mm radial offset from the axial center, using filtered back-projection with single-slice rebinning. The measured average radial and tangential resolutions (FWHM) were 1.38 mm and 1.39 mm, respectively. The 1.2 mm rods were separable in the hot-rod phantom using an iterative image reconstruction algorithm. The scatter fraction was 7.3% and peak noise equivalent count rate was 15.5 kcps at 65.1 MBq of activity. The FDG uptake in a mouse heart and brain were visible in the two in vivo simultaneous PET/MRI scans without applying image corrections. In conclusion, the insert demonstrated a good overall performance and can be used for small animal multi-modal research applications.

  6. PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner

    NASA Astrophysics Data System (ADS)

    Omidvari, Negar; Cabello, Jorge; Topping, Geoffrey; Schneider, Florian R.; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I.

    2017-11-01

    MADPET4 is the first small animal PET insert with two layers of individually read out crystals in combination with silicon photomultiplier technology. It has a novel detector arrangement, in which all crystals face the center of field of view transaxially. In this work, the PET performance of MADPET4 was evaluated and compared to other preclinical PET scanners using the NEMA NU 4 measurements, followed by imaging a mouse-size hot-rod resolution phantom and two in vivo simultaneous PET/MRI scans in a 7 T MRI scanner. The insert had a peak sensitivity of 0.49%, using an energy threshold of 350 keV. A uniform transaxial resolution was obtained up to 15 mm radial offset from the axial center, using filtered back-projection with single-slice rebinning. The measured average radial and tangential resolutions (FWHM) were 1.38 mm and 1.39 mm, respectively. The 1.2 mm rods were separable in the hot-rod phantom using an iterative image reconstruction algorithm. The scatter fraction was 7.3% and peak noise equivalent count rate was 15.5 kcps at 65.1 MBq of activity. The FDG uptake in a mouse heart and brain were visible in the two in vivo simultaneous PET/MRI scans without applying image corrections. In conclusion, the insert demonstrated a good overall performance and can be used for small animal multi-modal research applications.

  7. Free radical scavenging, antidiarrheal and anthelmintic activity of Pistia stratiotes L. extracts and its phytochemical analysis.

    PubMed

    Bin Karim, Mohammed Faisal; Imam, Hasan; Sarker, Md Moklesur-Rahman; Uddin, Nizam; Hasan, Nahid; Paul, Nirmala; Haque, Tahmina

    2015-05-01

    In this phyto-pharmacological screening of Pistia stratiotes L leaf and root extracts each separately in two different solvents demonstrated its potential medicinal value. Apparent antioxidant value is demonstrated by DPPH, Nitric oxide scavenging and Ferric ion reducing method. Additionally, total flavonoid and phenolic compounds were measured. The leaf methanolic extract scavenged both nitric oxide (NO) and DPPH radical with a dose dependent manner. But the pet ether fraction of root was found to have highest efficacy in Fe(3±) reducing power assay. Flavonoid was found to contain highest in the pet ether fraction of root (411.35mg/g) in terms of quercetin equivalent, similarly highest amount (34.96mg/g) of total phenolic compounds (assayed as gallic acid equivalents) were found to contain in the same fraction. The methanolic fractions appeared less cytotoxic compared to pet ether extracts. The plant extracts caused a dose dependent decrease in faecal droppings in both castor oil and magnesium sulphate induced diarrhea, where as leaf extracts in each solvent appeared most effective. Also, the plant extracts showed anthelmintic activity in earthworm by inducing paralysis and death in a dose dependent manner. At highest doses (50 mg/ml) all fractions were almost effective as the positive control piperazine citrate (10 mg/ml). Thus, besides this cytotoxic effect it's traditional claim for therapeutic use can never be overlooked.

  8. The relationship between thermal sensation and the rate of hospital admissions for cardiovascular disease in Kermanshah, Iran

    NASA Astrophysics Data System (ADS)

    Mohammadi, Bakhtiyar; Karimi, Shilan

    2017-11-01

    Climate and weather conditions are the most important factors that influence activities and human health. Bioclimatology/biometeorology are concerned with the study of weather effects on living creatures, including humans, plants, and animals. This research was prepared in order to understand the bioclimatic condition of Kermanshah and its relation to the level of hospital admissions of cardiovascular patients in this city. In addition to the climatic variables, the statistics on the number of daily admissions of cardiovascular patients in Kermanshah during March 27, 2009 to April 30, 2015 was prepared. First, Kermanshah's bioclimatic conditions were identified on a daily basis. Then, the relationship between each of the thermal sensations with the level of hospital admissions of cardiovascular patients in Kermanshah using Levene's test, univariate analysis of variance (ANOVA), Scheffe and Games-Howell post hoc tests was investigated. The results of this study showed that in each index, only very few bioclimatic conditions have had an impact on the increase of hospital admissions of cardiovascular diseases. For example, based on the equivalent temperature index (Tek or EqT), there is a significant relationship between extreme conditions and the rate of cardiovascular admissions. But, however, in the effective temperature index (TE), a significant correlation between warm/hot conditions and an increase in the number of cardiovascular admissions was seen. Based on the predicted mean vote (PMV) and physiological equivalent temperature (PET) indices, cool and cold conditions more than warm and comfort conditions have an effect on the number of hospital admissions of cardiovascular patients. Overall, the obtained results showed that the extreme climatic conditions were directly related to an increase in cardiovascular disease in Kermanshah.

  9. Assessment of human thermal comfort and mitigation measures in different urban climatotopes

    NASA Astrophysics Data System (ADS)

    Müller, N.; Kuttler, W.

    2012-04-01

    This study analyses thermal comfort in the model city of Oberhausen as an example for the densely populated metropolitan region Ruhr, Germany. As thermal loads increase due to climate change negative impacts especially for city dwellers will arise. Therefore mitigation strategies should be developed and considered in urban planning today to prevent future thermal stress. The method consists of the combination of in-situ measurements and numerical model simulations. So in a first step the actual thermal situation is determined and then possible mitigation strategies are derived. A measuring network was installed in eight climatotopes for a one year period recording air temperature, relative humidity, wind speed and wind direction. Based on these parameters the human thermal comfort in terms of physiological equivalent temperature (PET) was calculated by RayMan Pro software. Thus the human comfort of different climatotopes was determined. Heat stress in different land uses varies, so excess thermal loads in urban areas could be detected. Based on the measuring results mitigation strategies were developed, such as increasing areas with high evaporation capacity (green areas and water bodies). These strategies were implemented as different plan scenarios in the microscale urban climate model ENVI-met. The best measure should be identified by comparing the range and effect of these scenarios. Simulations were run in three of the eight climatotopes (city center, suburban and open land site) to analyse the effectiveness of the mitigation strategies in several land use structures. These cover the range of values of all eight climatotopes and therefore provide representative results. In the model area of 21 ha total, the modified section in the different plan scenarios was 1 ha. Thus the effect of small-scale changes could be analysed. Such areas can arise due to population decline and structural changes and hold conversion potential. Emphasis was also laid on analysing the effectiveness of water bodies, which need further research in contrast to well analysed vegetation areas. Results show different thermal loads in the miscellaneous climatotopes due to land use structures. Both measurements and model simulations demonstrate the positive effect on thermal comfort due to augmentation of areas with high evaporation capacity. These effects can be especially well detected in summer, when heat stress is most pronounced. The measurement based PET calculations show a maximum difference of 4 K PET between inner city and open land site in summer nights. Simulation results overall present a PET reduction of 1-3 K. The average PET reduction in the city center site is about 2 K, while the maximum reduction in the suburban site can exceed 5 K. In urban areas parks are particularly advisable as mitigation measure, because they reduce thermal stress both by tree shading and evapotranspiration.

  10. The thermal comfort and its changes in the 31 provincial capital cities of mainland China in the past 30 years

    NASA Astrophysics Data System (ADS)

    Chi, Xiaoli; Li, Rui; Cubasch, Ulrich; Cao, Wenting

    2018-04-01

    The thermal comfort and its changes in the 31 provincial capital cities of mainland China in the past 30 years were comprehensively evaluated using the Physiologically Equivalent Temperature (PET) and Universal Thermal Climate Index (UTCI) indicators. The PET and UTCI values were highly correlated with each other and presented similar thermal comfort pattern, although their sensitivities might differ slightly. The results showed that these cities covered, respectively, 4-8 and 6-8 thermal comfort classes of the PET and UTCI scale. On the whole, the annual cumulative number of pleasant days was more than 160 days/year. In terms of seasonal variations in thermal comfort conditions, the 31 provincial capital cities in mainland China can be classified into 5 types, which are, respectively, characterized by pleasant summer and severe cold winter (type-I); pleasant spring, autumn, winter, and severe hot summer (type-II); pleasant spring and autumn, slightly pleasant summer, and cold winter (type-III); pleasant spring and autumn, hot stress summer, and slightly cold winter (type-IV); and pleasant spring, summer, autumn, and cool winter (type-V). Type-II cities are rare winter resorts, while type-I cities are natural summer resorts. Type-V cities are the year round pleasant resorts. In the past three decades, the cities in mainland China had experienced increasing pleasant duration in late winter and early spring and intensifying heat stress in summer. The reduction in annual cumulative number of cold stress days in higher latitude/altitude cities outweighed the increase in duration of heat stress in subtropical cities. These may provide some references for urban planning and administration in mainland China.

  11. Ambient Dose Equivalent measured at the Instituto Nacional de Cancerologia Department of Nuclear Medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avila, O.; Torres-Ulloa, C. L.; Facultad de Ciencias, Universidad Nacional Autonoma de Mexico, AP 70-542, 04510, DF

    2010-12-07

    Ambient dose equivalent values were determined in several sites at the Instituto Nacional de Cancerologia, Departmento de Medicina Nuclear, using TLD-100 and TLD-900 thermoluminescent dosemeters. Additionally, ambient dose equivalent was measured at a corridor outside the hospitalization room for patients treated with {sup 137}Cs brachytherapy. Dosemeter calibration was performed at the Instituto Nacional de Investigaciones Nucleares, Laboratorio de Metrologia, to known {sup 137}Cs gamma radiation air kerma. Radionuclides considered for this study are {sup 131}I, {sup 18}F, {sup 67}Ga, {sup 99m}Tc, {sup 111}In, {sup 201}Tl and {sup 137}Cs, with main gamma energies between 93 and 662 keV. Dosemeters were placedmore » during a five month period in the nuclear medicine rooms (containing gamma-cameras), injection corridor, patient waiting areas, PET/CT study room, hot lab, waste storage room and corridors next to the hospitalization rooms for patients treated with {sup 131}I and {sup 137}Cs. High dose values were found at the waste storage room, outside corridor of {sup 137}Cs brachytherapy patients and PET/CT area. Ambient dose equivalent rate obtained for the {sup 137}Cs brachytherapy corridor is equal to (18.51{+-}0.02)x10{sup -3} mSv/h. Sites with minimum doses are the gamma camera rooms, having ambient dose equivalent rates equal to (0.05{+-}0.03)x10{sup -3} mSv/h. Recommendations have been given to the Department authorities so that further actions are taken to reduce doses at high dose sites in order to comply with the ALARA principle (as low as reasonably achievable).« less

  12. Thermogravimetric and calorimetric characteristics during co-pyrolysis of municipal solid waste components.

    PubMed

    Ansah, Emmanuel; Wang, Lijun; Shahbazi, Abolghasem

    2016-10-01

    The thermogravimetric and calorimetric characteristics during pyrolysis of wood, paper, textile and polyethylene terephthalate (PET) plastic in municipal solid wastes (MSW), and co-pyrolysis of biomass-derived and plastic components with and without torrefaction were investigated. The active pyrolysis of the PET plastic occurred at a much higher temperature range between 360°C and 480°C than 220-380°C for the biomass derived components. The plastic pyrolyzed at a heating rate of 10°C/min had the highest maximum weight loss rate of 18.5wt%/min occurred at 420°C, followed by 10.8wt%/min at 340°C for both paper and textile, and 9.9wt%/min at 360°C for wood. At the end of the active pyrolysis stage, the final mass of paper, wood, textile and PET was 28.77%, 26.78%, 21.62% and 18.31%, respectively. During pyrolysis of individual MSW components at 500°C, the wood required the least amount of heat at 665.2J/g, compared to 2483.2J/g for textile, 2059.4J/g for paper and 2256.1J/g for PET plastic. The PET plastic had much higher activation energy of 181.86kJ/mol, compared to 41.47kJ/mol for wood, 50.01kJ/mol for paper and 36.65kJ/mol for textile during pyrolysis at a heating rate of 10°C/min. H2O and H2 peaks were observed on the MS curves for the pyrolysis of three biomass-derived materials but there was no obvious H2O and H2 peaks on the MS curves of PET plastic. There was a significant interaction between biomass and PET plastic during co-pyrolysis if the biomass fraction was dominant. The amount of heat required for the co-pyrolysis of the biomass and plastic mixture increased with the increase of plastic mass fraction in the mixture. Torrefaction at a proper temperature and time could improve the grindability of PET plastic. The increase of torrefaction temperature and time did not affect the temperature where the maximum pyrolytic rates occurred for both biomass and plastic but decreased the maximum pyrolysis rate of biomass and increased the maximum pyrolysis rate of PET plastic. The amount of heat for the pyrolysis of biomass and PET mixture co-torrefied at 280°C for 30min was 4365J/g at 500°C, compared to 1138J/g for the pyrolysis of raw 50% wood and 50% PET mixture at the same condition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients.

    PubMed

    Grueneisen, Johannes; Sawicki, Lino Morris; Wetter, Axel; Kirchner, Julian; Kinner, Sonja; Aktas, Bahriye; Forsting, Michael; Ruhlmann, Verena; Umutlu, Lale

    2017-04-01

    To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (p<0.05). Furthermore, all three PET/MR sequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p>0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2w HASTE and diffusion-weighted imaging. Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer recurrences in the three PET/MR readings, the application of contrast-agent and the inclusion of DWI in the study protocol seems to be debatable. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. [Development of analysis software package for the two kinds of Japanese fluoro-d-glucose-positron emission tomography guideline].

    PubMed

    Matsumoto, Keiichi; Endo, Keigo

    2013-06-01

    Two kinds of Japanese guidelines for the data acquisition protocol of oncology fluoro-D-glucose-positron emission tomography (FDG-PET)/computed tomography (CT) scans were created by the joint task force of the Japanese Society of Nuclear Medicine Technology (JSNMT) and the Japanese Society of Nuclear Medicine (JSNM), and published in Kakuigaku-Gijutsu 27(5): 425-456, 2007 and 29(2): 195-235, 2009. These guidelines aim to standardize PET image quality among facilities and different PET/CT scanner models. The objective of this study was to develop a personal computer-based performance measurement and image quality processor for the two kinds of Japanese guidelines for oncology (18)F-FDG PET/CT scans. We call this software package the "PET quality control tool" (PETquact). Microsoft Corporation's Windows(™) is used as the operating system for PETquact, which requires 1070×720 image resolution and includes 12 different applications. The accuracy was examined for numerous applications of PETquact. For example, in the sensitivity application, the system sensitivity measurement results were equivalent when comparing two PET sinograms obtained from the PETquact and the report. PETquact is suited for analysis of the two kinds of Japanese guideline, and it shows excellent spec to performance measurements and image quality analysis. PETquact can be used at any facility if the software package is installed on a laptop computer.

  15. Neutron spectra due (13)N production in a PET cyclotron.

    PubMed

    Benavente, J A; Vega-Carrillo, H R; Lacerda, M A S; Fonseca, T C F; Faria, F P; da Silva, T A

    2015-05-01

    Monte Carlo and experimental methods have been used to characterize the neutron radiation field around PET (Positron Emission Tomography) cyclotrons. In this work, the Monte Carlo code MCNPX was used to estimate the neutron spectra, the neutron fluence rates and the ambient dose equivalent (H*(10)) in seven locations around a PET cyclotron during (13)N production. In order to validate these calculations, H*(10) was measured in three sites and were compared with the calculated doses. All the spectra have two peaks, one above 0.1MeV due to the evaporation neutrons and another in the thermal region due to the room-return effects. Despite the relatively large difference between the measured and calculated H*(10) for one point, the agreement was considered good, compared with that obtained for (18)F production in a previous work. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. High-performance polymer/layered silicate nanocomposites

    NASA Astrophysics Data System (ADS)

    Heidecker, Matthew J.

    High-performance layered-silicate nanocomposites of Polycarbonate (PC), poly(ethylene terephthalate) (PET), and their blends were produced via conventional melt-blending techniques. The focus of this thesis was on the fundamentals of dispersion, control of thermal stability, maintenance of melt-blending processing conditions, and on optimization of the composites' mechanical properties via the design of controlled and thermodynamically favorable nano-filler dispersions within the polymer matrices. PET and PC require high temperatures for melt-processing, rendering impractical the use of conventional/commercial organically-modified layered-silicates, since the thermal degradation temperatures of their ammonium surfactants lies below the typical processing temperatures. Thus, different surfactant chemistries must be employed in order to develop melt-processable nanocomposites, also accounting for polymer matrix degradation due to water (PET) or amine compounds (PC). Novel high thermal-stability surfactants were developed and employed in montmorillonite nanocomposites of PET, PC, and PC/PET blends, and were compared to the respective nanocomposites based on conventional quaternary-ammonium modified montmorillonites. Favorable dispersion was achieved in all cases, however, the overall material behavior -- i.e., the combination of crystallization, mechanical properties, and thermal degradation -- was better for the nanocomposites based on the thermally-stable surfactant fillers. Studies were also done to trace, and ultimately limit, the matrix degradation of Polycarbonate/montmorillonite nanocomposites, through varying the montmorillonite surfactant chemistry, processing conditions, and processing additives. Molecular weight degradation was, maybe surprisingly, better controlled in the conventional quaternary ammonium based nanocomposites -- even though the thermal stability of the organically modified montmorillonites was in most cases the lowest. Dependence of the resultant nanocomposites' mechanical properties on the preferential alignment of the montmorillonite nano-platelet was also evaluated. Highly aligned filler platelets did not result in an additional enhancement in mechanical properties. PC/PET blends and their respective PC/PET/montmorillonite nanocomposites were synthesized and compared. The dispersion of the organically modified nano-fillers in the PC/PET blends was controlled via thermodynamic considerations, realized through proper surfactant choice: Nanocomposites in which the layered silicate was preferentially sequestered in the PET phase were designed and synthesized. This preferential dispersion of the nano-filler in the PET phase of the PC/PET blend was insensitive to processing conditions, including approaches employing a master-batch (filler concentrate); regardless of the master-batch matrix, both PC and PET were employed, thermodynamics drove the layered silicate to preferentially migrate to the PET phase of the PC/PET blend. In a second approach, the development of a nanocomposite with controlled PC/PET compatibilization near the montmorillonite platelets, in absence of appreciable transesterification reactions, led to the formation of very high performance nanocomposites. These latter systems, point to an exciting new avenue of future considerations for nanocomposite blends with selective nano-filler dispersions, where performance can be tailored via the controlled preferential dispersion of nano-fillers in one phase, or by filler-induced polymer compatibilization.

  17. Human thermal bioclimatic conditions associated with acute cardiovascular syndromes in Crete Island, Greece

    NASA Astrophysics Data System (ADS)

    Bleta, Anastasia G.; Nastos, Panagiotis T.

    2013-04-01

    The aim of this study is to quantify the association between bioclimatic conditions and daily counts of admissions for non-fatal acute cardiovascular (acute coronary syndrome, arrhythmia, decompensation of heart failure) syndromes (ACS) registered by the two main hospitals in Heraklion, Crete Island, during a five-year period 2008-2012. The bioclimatic conditions analyzed are based on human thermal bioclimatic indices such as the Physiological Equivalent Temperature (PET) and the Universal Thermal Climate Index (UTCI). Mean daily meteorological parameters, such as air temperature, relative humidity, wind speed and cloudiness, were acquired from the meteorological station of Heraklion (Hellenic National Meteorological Service). These parameters were used as input variables in modeling the aforementioned thermal indices, in order to interpret the grade of the thermo-physiological stress. The PET and UTCI analysis was performed by the use of the radiation and bioclimate model, "RayMan", which is well-suited to calculate radiation fluxes and human biometeorological indices. Generalized linear models (GLM) were applied to time series of daily numbers of outpatients with ACS against bioclimatic variations, after controlling for possible confounders and adjustment for season and trends. The interpretation of the results of this analysis suggests a significant association between cold weather and increased coronary heart disease incidence, especially in the elderly and males. Additionally, heat stress plays an important role in the configuration of daily ACS outpatients, even in temperate climate, as that in Crete Island. In this point it is worth mentioning that Crete Island is frequently affected by Saharan outbreaks, which are associated in many cases with miscellaneous phenomena, such as Föhn winds - hot and dry winds - causing extreme bioclimatic conditions (strong heat stress). Taking into consideration the projected increased ambient temperature in the future, ACS exacerbation is very likely to happen during the warm period, against mitigation during the cold period of the year.

  18. Derivation of the scan time requirement for maintaining a consistent PET image quality

    NASA Astrophysics Data System (ADS)

    Kim, Jin Su; Lee, Jae Sung; Kim, Seok-Ki

    2015-05-01

    Objectives: the image quality of PET for larger patients is relatively poor, even though the injection dose is optimized considering the NECR characteristics of the PET scanner. This poor image quality is due to the lower level of maximum NECR that can be achieved in these large patients. The aim of this study was to optimize the PET scan time to obtain a consistent PET image quality regardless of the body size, based on the relationship between the patient specific NECR (pNECR) and body weight. Methods: eighty patients (M/F=53/27, body weight: 059 ± 1 kg) underwent whole-body FDG PET scans using a Philips GEMINI GS PET/CT scanner after an injection of 0.14 mCi/kg FDG. The relationship between the scatter fraction (SF) and body weight was determined by repeated Monte Carlo simulations using a NEMA scatter phantom, the size of which varied according to the relationship between the abdominal circumference and body weight. Using this information, the pNECR was calculated from the prompt and delayed PET sinograms to obtain the prediction equation of NECR vs. body weight. The time scaling factor (FTS) for the scan duration was finally derived to make PET images with equivalent SNR levels. Results: the SF and NECR had the following nonlinear relationships with the body weight: SF=0.15 ṡ body weight0.3 and NECR = 421.36 (body weight)-0.84. The equation derived for FTS was 0.01ṡ body weight + 0.2, which means that, for example, a 120-kg person should be scanned 1.8 times longer than a 70 kg person, or the scan time for a 40-kg person can be reduced by 30%. Conclusion: the equation of the relative time demand derived in this study will be useful for maintaining consistent PET image quality in clinics.

  19. PET/CT imaging for treatment verification after proton therapy: A study with plastic phantoms and metallic implants

    PubMed Central

    Parodi, Katia; Paganetti, Harald; Cascio, Ethan; Flanz, Jacob B.; Bonab, Ali A.; Alpert, Nathaniel M.; Lohmann, Kevin; Bortfeld, Thomas

    2008-01-01

    The feasibility of off-line positron emission tomography/computed tomography (PET/CT) for routine three dimensional in-vivo treatment verification of proton radiation therapy is currently under investigation at Massachusetts General Hospital in Boston. In preparation for clinical trials, phantom experiments were carried out to investigate the sensitivity and accuracy of the method depending on irradiation and imaging parameters. Furthermore, they addressed the feasibility of PET/CT as a robust verification tool in the presence of metallic implants. These produce x-ray CT artifacts and fluence perturbations which may compromise the accuracy of treatment planning algorithms. Spread-out Bragg peak proton fields were delivered to different phantoms consisting of polymethylmethacrylate (PMMA), PMMA stacked with lung and bone equivalent materials, and PMMA with titanium rods to mimic implants in patients. PET data were acquired in list mode starting within 20 min after irradiation at a commercial luthetium-oxyorthosilicate (LSO)-based PET/CT scanner. The amount and spatial distribution of the measured activity could be well reproduced by calculations based on the GEANT4 and FLUKA Monte Carlo codes. This phantom study supports the potential of millimeter accuracy for range monitoring and lateral field position verification even after low therapeutic dose exposures of 2 Gy, despite the delay between irradiation and imaging. It also indicates the value of PET for treatment verification in the presence of metallic implants, demonstrating a higher sensitivity to fluence perturbations in comparison to a commercial analytical treatment planning system. Finally, it addresses the suitability of LSO-based PET detectors for hadron therapy monitoring. This unconventional application of PET involves countrates which are orders of magnitude lower than in diagnostic tracer imaging, i.e., the signal of interest is comparable to the noise originating from the intrinsic radioactivity of the detector itself. In addition to PET alone, PET/CT imaging provides accurate information on the position of the imaged object and may assess possible anatomical changes during fractionated radiotherapy in clinical applications. PMID:17388158

  20. Regional projection of climate impact indices over the Mediterranean region

    NASA Astrophysics Data System (ADS)

    Casanueva, Ana; Frías, M.; Dolores; Herrera, Sixto; Bedia, Joaquín; San Martín, Daniel; Gutiérrez, José Manuel; Zaninovic, Ksenija

    2014-05-01

    Climate Impact Indices (CIIs) are being increasingly used in different socioeconomic sectors to transfer information about climate change impacts and risks to stakeholders. CIIs are typically based on different weather variables such as temperature, wind speed, precipitation or humidity and comprise, in a single index, the relevant meteorological information for the particular impact sector (in this study wildfires and tourism). This dependence on several climate variables poses important limitations to the application of statistical downscaling techniques, since physical consistency among variables is required in most cases to obtain reliable local projections. The present study assesses the suitability of the "direct" downscaling approach, in which the downscaling method is directly applied to the CII. In particular, for illustrative purposes, we consider two popular indices used in the wildfire and tourism sectors, the Fire Weather Index (FWI) and the Physiological Equivalent Temperature (PET), respectively. As an example, two case studies are analysed over two representative Mediterranean regions of interest for the EU CLIM-RUN project: continental Spain for the FWI and Croatia for the PET. Results obtained with this "direct" downscaling approach are similar to those found from the application of the statistical downscaling to the individual meteorological drivers prior to the index calculation ("component" downscaling) thus, a wider range of statistical downscaling methods could be used. As an illustration, future changes in both indices are projected by applying two direct statistical downscaling methods, analogs and linear regression, to the ECHAM5 model. Larger differences were found between the two direct statistical downscaling approaches than between the direct and the component approaches with a single downscaling method. While these examples focus on particular indices and Mediterranean regions of interest for CLIM-RUN stakeholders, the same study could be extended to other indices and regions.

  1. Antimony leaching from polyethylene terephthalate (PET) plastic used for bottled drinking water.

    PubMed

    Westerhoff, Paul; Prapaipong, Panjai; Shock, Everett; Hillaireau, Alice

    2008-02-01

    Antimony is a regulated contaminant that poses both acute and chronic health effects in drinking water. Previous reports suggest that polyethylene terephthalate (PET) plastics used for water bottles in Europe and Canada leach antimony, but no studies on bottled water in the United States have previously been conducted. Nine commercially available bottled waters in the southwestern US (Arizona) were purchased and tested for antimony concentrations as well as for potential antimony release by the plastics that compose the bottles. The southwestern US was chosen for the study because of its high consumption of bottled water and elevated temperatures, which could increase antimony leaching from PET plastics. Antimony concentrations in the bottled waters ranged from 0.095 to 0.521 ppb, well below the US Environmental Protection Agency (USEPA) maximum contaminant level (MCL) of 6 ppb. The average concentration was 0.195+/-0.116 ppb at the beginning of the study and 0.226+/-0.160 ppb 3 months later, with no statistical differences; samples were stored at 22 degrees C. However, storage at higher temperatures had a significant effect on the time-dependent release of antimony. The rate of antimony (Sb) release could be fit by a power function model (Sb(t)=Sb 0 x[Time, h]k; k=8.7 x 10(-6)x[Temperature ( degrees C)](2.55); Sb 0 is the initial antimony concentration). For exposure temperatures of 60, 65, 70, 75, 80, and 85 degrees C, the exposure durations necessary to exceed the 6 ppb MCL are 176, 38, 12, 4.7, 2.3, and 1.3 days, respectively. Summertime temperatures inside of cars, garages, and enclosed storage areas can exceed 65 degrees C in Arizona, and thus could promote antimony leaching from PET bottled waters. Microwave digestion revealed that the PET plastic used by one brand contained 213+/-35 mgSb/kg plastic; leaching of all the antimony from this plastic into 0.5L of water in a bottle could result in an antimony concentration of 376 ppb. Clearly, only a small fraction of the antimony in PET plastic bottles is released into the water. Still, the use of alternative types of plastics that do not leach antimony should be considered, especially for climates where exposure to extreme conditions can promote antimony release from PET plastics.

  2. Hydrogenated amorphous silicon solar cells fabricated at low substrate temperature 110°C on flexible PET substrate

    NASA Astrophysics Data System (ADS)

    Ramakrishna, M.; Kumari, Juhi; Venkanna, K.; Agarwal, Pratima

    2018-05-01

    In this paper, we report a-Si:H solar cells fabricated on flexible Polyethylene terephthalate (PET) and corning glass. The a-Si:H thin films were prepared at low substrate temperature (110oC) on corning 1737 glass with different rf powers. The influence of rf power on structural and optoelectronic properties of i-a-Si:H were studied. The films deposited at rf power 50W show less broadening of <ɛ2> peak. This indicates these films are more ordered. With this optimized parameter for i-layer, solar cells fabricated on flexible PET substrate show best efficiency of 3.3% whereas on corning glass 3.82%.

  3. High dose microCT does not contribute towards improved microPET/CT image quantitative accuracy and can limit longitudinal scanning of small animals

    NASA Astrophysics Data System (ADS)

    McDougald, Wendy A.; Collins, Richard; Green, Mark; Tavares, Adriana A. S.

    2017-10-01

    Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT) imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1) to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2) to evaluate the absorbed dose associated with varying CT parameters. Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA) software implemented by Mediso. Measured Hounsfield Unit (HU) in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC), uniformity and quantitative bias were also measured. Results: Only less than 2% and 1% of CT acquisition protocols yielded water HU values < -80 and air HU values < -840, respectively. Four out of eleven CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration. Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed towards improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.

  4. Structural Characteristics of the Plasmid-Encoded Toxin from Enteroaggregative Escherichia coli†

    PubMed Central

    Scaglione, Patricia; Nemec, Kathleen N.; Burlingame, Kaitlin E.; Grabon, Agnieszka; Huerta, Jazmin; Navarro-García, Fernando; Tatulian, Suren A.; Teter, Ken

    2008-01-01

    Intoxication by the plasmid-encoded toxin (Pet) of enteroaggregative Escherichia coli requires toxin translocation from the endoplasmic reticulum (ER) to the cytosol. This event involves the quality control system of ER-associated degradation (ERAD), but the molecular details of the process are poorly characterized. For many structurally distinct AB-type toxins, ERAD-mediated translocation is triggered by the spontaneous unfolding of a thermally unstable A chain. Here we show that Pet, a non-AB toxin, engages ERAD by a different mechanism that does not involve thermal unfolding. Circular dichroism and fluorescence spectroscopy measurements demonstrated that Pet maintains most of its secondary and tertiary structural features at 37°C, with significant thermal unfolding only occurring at temperatures ≥50°C. Fluorescence quenching experiments detected the partial solvent exposure of Pet aromatic amino acid residues at 37°C, and a cell-based assay suggested these changes could activate an ERAD-related event known as the unfolded protein response. We also found that HEp-2 cells were resistant to Pet intoxication when incubated with glycerol, a protein stabilizer. Altogether, our data are consistent with a model in which ERAD activity is triggered by a subtle structural destabilization of Pet and the exposure of Pet hydrophobic residues at physiological temperature. This was further supported by computer modeling analysis, which identified a surface-exposed hydrophobic loop among other accessible nonpolar residues in Pet. From our data it appears that Pet can promote its ERAD-mediated translocation into the cytosol by a distinct mechanism involving partial exposure of hydrophobic residues rather than the substantial unfolding observed for certain AB toxins. PMID:18702515

  5. Studies of a Next-Generation Silicon-Photomultiplier-Based Time-of-Flight PET/CT System.

    PubMed

    Hsu, David F C; Ilan, Ezgi; Peterson, William T; Uribe, Jorge; Lubberink, Mark; Levin, Craig S

    2017-09-01

    This article presents system performance studies for the Discovery MI PET/CT system, a new time-of-flight system based on silicon photomultipliers. System performance and clinical imaging were compared between this next-generation system and other commercially available PET/CT and PET/MR systems, as well as between different reconstruction algorithms. Methods: Spatial resolution, sensitivity, noise-equivalent counting rate, scatter fraction, counting rate accuracy, and image quality were characterized with the National Electrical Manufacturers Association NU-2 2012 standards. Energy resolution and coincidence time resolution were measured. Tests were conducted independently on two Discovery MI scanners installed at Stanford University and Uppsala University, and the results were averaged. Back-to-back patient scans were also performed between the Discovery MI, Discovery 690 PET/CT, and SIGNA PET/MR systems. Clinical images were reconstructed using both ordered-subset expectation maximization and Q.Clear (block-sequential regularized expectation maximization with point-spread function modeling) and were examined qualitatively. Results: The averaged full widths at half maximum (FWHMs) of the radial/tangential/axial spatial resolution reconstructed with filtered backprojection at 1, 10, and 20 cm from the system center were, respectively, 4.10/4.19/4.48 mm, 5.47/4.49/6.01 mm, and 7.53/4.90/6.10 mm. The averaged sensitivity was 13.7 cps/kBq at the center of the field of view. The averaged peak noise-equivalent counting rate was 193.4 kcps at 21.9 kBq/mL, with a scatter fraction of 40.6%. The averaged contrast recovery coefficients for the image-quality phantom were 53.7, 64.0, 73.1, 82.7, 86.8, and 90.7 for the 10-, 13-, 17-, 22-, 28-, and 37-mm-diameter spheres, respectively. The average photopeak energy resolution was 9.40% FWHM, and the average coincidence time resolution was 375.4 ps FWHM. Clinical image comparisons between the PET/CT systems demonstrated the high quality of the Discovery MI. Comparisons between the Discovery MI and SIGNA showed a similar spatial resolution and overall imaging performance. Lastly, the results indicated significantly enhanced image quality and contrast-to-noise performance for Q.Clear, compared with ordered-subset expectation maximization. Conclusion: Excellent performance was achieved with the Discovery MI, including 375 ps FWHM coincidence time resolution and sensitivity of 14 cps/kBq. Comparisons between reconstruction algorithms and other multimodal silicon photomultiplier and non-silicon photomultiplier PET detector system designs indicated that performance can be substantially enhanced with this next-generation system. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  6. Measurement of radioactivity concentration in blood by using newly developed ToT LuAG-APD based small animal PET tomograph.

    PubMed

    Malik, Azhar H; Shimazoe, Kenji; Takahashi, Hiroyuki

    2013-01-01

    In order to obtain plasma time activity curve (PTAC), input function for almost all quantitative PET studies, patient blood is sampled manually from the artery or vein which has various drawbacks. Recently a novel compact Time over Threshold (ToT) based Pr:LuAG-APD animal PET tomograph is developed in our laboratory which has 10% energy resolution, 4.2 ns time resolution and 1.76 mm spatial resolution. The measured value of spatial resolution shows much promise for imaging the blood vascular, i.e; artery of diameter 2.3-2.4mm, and hence, to measure PTAC for quantitative PET studies. To find the measurement time required to obtain reasonable counts for image reconstruction, the most important parameter is the sensitivity of the system. Usually small animal PET systems are characterized by using a point source in air. We used Electron Gamma Shower 5 (EGS5) code to simulate a point source at different positions inside the sensitive volume of tomograph and the axial and radial variations in the sensitivity are studied in air and phantom equivalent water cylinder. An average sensitivity difference of 34% in axial direction and 24.6% in radial direction is observed when point source is displaced inside water cylinder instead of air.

  7. How Accurate is Land/Ocean Moisture Transport Variability in Reanalyses?

    NASA Technical Reports Server (NTRS)

    Robertson, F. R.; Bosilovich, M. G.

    2014-01-01

    Quantifying the global hydrological cycle and its variability across various time scales remains a challenge to the climate community. Direct measurements of evaporation (E), evapotranspiration (ET), and precipitation (P) are not feasible on a global scale, nor is the transport of water vapor over the global oceans and sparsely populated land areas. Expanding satellite data streams have enabled development of various water (and energy) flux products, complementing reanalyses and facilitating observationally constrained modeling. But the evolution of the global observing system has produced additional complications--improvements in satellite sensor resolution and accuracy have resulted in "epochs" of observational quasi-uniformity that can adversely affect reanalysis trends. In this work we focus on vertically integrated moisture flux convergence (VMFC) variations within the period 1979 - present integrated over global land. We show that VMFC in recent reanalyses (e.g. ERA-I, NASA MERRA, NOAA CFSR and JRA55) suffers from observing system changes, though differently in each product. Land Surface Models (LSMs) forced with observations-based precipitation, radiation and near-surface meteorology share closely the interannual P-ET variations of the reanalyses associated with ENSO events. (VMFC over land and P-ET estimates are equivalent quantities since atmospheric storage changes are small on these scales.) But the long-term LSM trend over the period since 1979 is approximately one-fourth that of the reanalyses. Additional reduced observation reanalyses assimilating only surface pressure and /or specifying seasurface temperature also have a much smaller trend in P-ET like the LSMs. We explore the regional manifestation of the reanalysis P-ET / VMFC problems, particularly over land. Both principal component analysis and a simple time series changepoint analysis highlight problems associated with data poor regions such as Equatorial Africa and, for one reanalysis, the Equatorial Andes region. Onset of the availability of passive microwave Special Sensor Microwave Imager (SSMI) moisture data in July 1987 and the transition from the Microwave Sounder Unit (MSU) to an advanced version (AMSU) have significant impacts on VMFC variability. Simple accounting for these errors of leading importance results in modified reanalysis VMFC estimates that agree much better with the LSM results. Regional details of the modified reanalysis VMFC and LSM P-ET are related to changes in Pacific Decadal Variability as manifest in SST changes after the late 1990s.

  8. Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE

    NASA Astrophysics Data System (ADS)

    Lamare, F.; Turzo, A.; Bizais, Y.; Cheze LeRest, C.; Visvikis, D.

    2006-02-01

    A newly developed simulation toolkit, GATE (Geant4 Application for Tomographic Emission), was used to develop a Monte Carlo simulation of a fully three-dimensional (3D) clinical PET scanner. The Philips Allegro/GEMINI PET systems were simulated in order to (a) allow a detailed study of the parameters affecting the system's performance under various imaging conditions, (b) study the optimization and quantitative accuracy of emission acquisition protocols for dynamic and static imaging, and (c) further validate the potential of GATE for the simulation of clinical PET systems. A model of the detection system and its geometry was developed. The accuracy of the developed detection model was tested through the comparison of simulated and measured results obtained with the Allegro/GEMINI systems for a number of NEMA NU2-2001 performance protocols including spatial resolution, sensitivity and scatter fraction. In addition, an approximate model of the system's dead time at the level of detected single events and coincidences was developed in an attempt to simulate the count rate related performance characteristics of the scanner. The developed dead-time model was assessed under different imaging conditions using the count rate loss and noise equivalent count rates performance protocols of standard and modified NEMA NU2-2001 (whole body imaging conditions) and NEMA NU2-1994 (brain imaging conditions) comparing simulated with experimental measurements obtained with the Allegro/GEMINI PET systems. Finally, a reconstructed image quality protocol was used to assess the overall performance of the developed model. An agreement of <3% was obtained in scatter fraction, with a difference between 4% and 10% in the true and random coincidence count rates respectively, throughout a range of activity concentrations and under various imaging conditions, resulting in <8% differences between simulated and measured noise equivalent count rates performance. Finally, the image quality validation study revealed a good agreement in signal-to-noise ratio and contrast recovery coefficients for a number of different volume spheres and two different (clinical level based) tumour-to-background ratios. In conclusion, these results support the accurate modelling of the Philips Allegro/GEMINI PET systems using GATE in combination with a dead-time model for the signal flow description, which leads to an agreement of <10% in coincidence count rates under different imaging conditions and clinically relevant activity concentration levels.

  9. Fabricating metal-oxide-semiconductor field-effect transistors on a polyethylene terephthalate substrate by applying low-temperature layer transfer of a single-crystalline silicon layer by meniscus force

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakaike, Kohei; Akazawa, Muneki; Nakamura, Shogo

    2013-12-02

    A low-temperature local-layer technique for transferring a single-crystalline silicon (c-Si) film by using a meniscus force was proposed, and an n-channel metal-oxide-semiconductor field-effect transistor (MOSFET) was fabricated on polyethylene terephthalate (PET) substrate. It was demonstrated that it is possible to transfer and form c-Si films in the required shape at the required position on PET substrates at extremely low temperatures by utilizing a meniscus force. The proposed technique for layer transfer was applied for fabricating high-performance c-Si MOSFETs on a PET substrate. The fabricated MOSFET showed a high on/off ratio of more than 10{sup 8} and a high field-effect mobilitymore » of 609 cm{sup 2} V{sup −1} s{sup −1}.« less

  10. Simultaneous maximum a posteriori longitudinal PET image reconstruction

    NASA Astrophysics Data System (ADS)

    Ellis, Sam; Reader, Andrew J.

    2017-09-01

    Positron emission tomography (PET) is frequently used to monitor functional changes that occur over extended time scales, for example in longitudinal oncology PET protocols that include routine clinical follow-up scans to assess the efficacy of a course of treatment. In these contexts PET datasets are currently reconstructed into images using single-dataset reconstruction methods. Inspired by recently proposed joint PET-MR reconstruction methods, we propose to reconstruct longitudinal datasets simultaneously by using a joint penalty term in order to exploit the high degree of similarity between longitudinal images. We achieved this by penalising voxel-wise differences between pairs of longitudinal PET images in a one-step-late maximum a posteriori (MAP) fashion, resulting in the MAP simultaneous longitudinal reconstruction (SLR) method. The proposed method reduced reconstruction errors and visually improved images relative to standard maximum likelihood expectation-maximisation (ML-EM) in simulated 2D longitudinal brain tumour scans. In reconstructions of split real 3D data with inserted simulated tumours, noise across images reconstructed with MAP-SLR was reduced to levels equivalent to doubling the number of detected counts when using ML-EM. Furthermore, quantification of tumour activities was largely preserved over a variety of longitudinal tumour changes, including changes in size and activity, with larger changes inducing larger biases relative to standard ML-EM reconstructions. Similar improvements were observed for a range of counts levels, demonstrating the robustness of the method when used with a single penalty strength. The results suggest that longitudinal regularisation is a simple but effective method of improving reconstructed PET images without using resolution degrading priors.

  11. Migration of antimony from PET trays into food simulant and food: determination of Arrhenius parameters and comparison of predicted and measured migration data

    PubMed Central

    Haldimann, M.; Alt, A.; Blanc, A.; Brunner, K.; Sager, F.; Dudler, V.

    2013-01-01

    Migration experiments with small sheets cut out from ovenable PET trays were performed in two-sided contact with 3% acetic acid as food simulant at various temperatures. The fraction of diffusible antimony (Sb) was estimated to be 62% in the PET sample under study. Apparent diffusion coefficients of Sb in PET trays were determined experimentally. Measurement of migration between 20 and 150°C yielded a linear Arrhenius plot over a wide temperature range from which the activation energy (Ea) of 188 ± 36 kJ mol−1 and the pre-exponential factor (D0) of 3.6 × 1014 cm2s−1 were determined for diffusing Sb species. Ea was similar to previously reported values for PET bottles obtained with a different experimental approach. Ea and D0 were applied as model parameters in migration modelling software for predicting the Sb transfer in real food. Ready meals intended for preparation in a baking oven were heated in the PET trays under study and the actual Sb migration into the food phase was measured by isotope dilution ICP-MS. It was shown that the predictive modelling reproduces correctly experimental data. PMID:23286325

  12. Migration of antimony from PET trays into food simulant and food: determination of Arrhenius parameters and comparison of predicted and measured migration data.

    PubMed

    Haldimann, M; Alt, A; Blanc, A; Brunner, K; Sager, F; Dudler, V

    2013-01-01

    Migration experiments with small sheets cut out from ovenable PET trays were performed in two-sided contact with 3% acetic acid as food simulant at various temperatures. The fraction of diffusible antimony (Sb) was estimated to be 62% in the PET sample under study. Apparent diffusion coefficients of Sb in PET trays were determined experimentally. Measurement of migration between 20 and 150°C yielded a linear Arrhenius plot over a wide temperature range from which the activation energy (E(a)) of 188 ± 36 kJ mol(-1) and the pre-exponential factor (D(0)) of 3.6 × 10(14) cm(2) s(-1) were determined for diffusing Sb species. E (a) was similar to previously reported values for PET bottles obtained with a different experimental approach. E (a) and D (0) were applied as model parameters in migration modelling software for predicting the Sb transfer in real food. Ready meals intended for preparation in a baking oven were heated in the PET trays under study and the actual Sb migration into the food phase was measured by isotope dilution ICP-MS. It was shown that the predictive modelling reproduces correctly experimental data.

  13. Static liquid permeation cell method for determining the migration parameters of low molecular weight organic compounds in polyethylene terephthalate.

    PubMed

    Song, Yoon S; Koontz, John L; Juskelis, Rima O; Zhao, Yang

    2013-01-01

    The migration of low molecular weight organic compounds through polyethylene terephthalate (PET) films was determined by using a custom permeation cell assembly. Fatty food simulant (Miglyol 812) was added to the receptor chamber, while the donor chamber was filled with 1% and 10% (v/v) migrant compounds spiked in simulant. The permeation cell was maintained at 40°C, 66°C, 100°C or 121°C for up to 25 days of polymer film exposure time. Migrants in Miglyol were directly quantified without a liquid-liquid extraction step by headspace-GC-MS analysis. Experimental diffusion coefficients (DP) of toluene, benzyl alcohol, ethyl butyrate and methyl salicylate through PET film were determined. Results from Limm's diffusion model showed that the predicted DP values for PET were all greater than the experimental values. DP values predicted by Piringer's diffusion model were also greater than those determined experimentally at 66°C, 100°C and 121°C. However, Piringer's model led to the underestimation of benzyl alcohol (Áp = 3.7) and methyl salicylate (Áp = 4.0) diffusion at 40°C with its revised "upper-bound" Áp value of 3.1 at temperatures below the glass transition temperature (Tg) of PET (<70°C). This implies that input parameters of Piringer's model may need to be revised to ensure a margin of safety for consumers. On the other hand, at temperatures greater than the Tg, both models appear too conservative and unrealistic. The highest estimated Áp value from Piringer's model was 2.6 for methyl salicylate, which was much lower than the "upper-bound" Áp value of 6.4 for PET. Therefore, it may be necessary further to refine "upper-bound" Áp values for PET such that Piringer's model does not significantly underestimate or overestimate the migration of organic compounds dependent upon the temperature condition of the food contact material.

  14. Thermal regulation of tightly packed solid-state photodetectors in a 1 mm3 resolution clinical PET system

    PubMed Central

    Vandenbroucke, A.; Innes, D.; Lau, F. W. Y.; Hsu, D. F. C.; Reynolds, P. D.; Levin, Craig S.

    2015-01-01

    Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm3 resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm3 LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image. PMID:25563270

  15. Thermal regulation of tightly packed solid-state photodetectors in a 1 mm{sup 3} resolution clinical PET system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freese, D. L.; Vandenbroucke, A.; Innes, D.

    2015-01-15

    Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under constructionmore » consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image.« less

  16. The Effect of Adding PET (Polyethylen Terephthalate) Plastic Waste on SCC (Self-Compacting Concrete) to Fresh Concrete Behavior and Mechanical Characteristics

    NASA Astrophysics Data System (ADS)

    Aswatama W, K.; Suyoso, H.; Meyfa U, N.; Tedy, P.

    2018-01-01

    To study the effect PET waste plastics on SCC then PET plastic waste content for SCC is made into 2.5%; 5%; 7.5%; and 10%. As reference concrete is made SCC with 0% PET level. The results on all fresh concrete test items indicate that for all PET waste levels made are meeting the criteria as SCC. The effect of adding PET to fresh concrete behavior on all test items shows that the filling ability and passing ability of concrete work increases with increasing of PET. However, the increase in PET will decrease its mechanical properties. The result of heat test shows that the mechanical properties of concrete (compressive strength, splitting, and elastic modulus) after heating at 250°C temperature has not changed, while at 600°C has significant capacity decline. To clarify the differences between SCC before and after heating, microstructure analysis was done in the form of photo magnification of specimen using SEM (Scanning Electron Microscope).

  17. Outdoor thermal comfort study in a sub-tropical climate: a longitudinal study based in Hong Kong

    NASA Astrophysics Data System (ADS)

    Cheng, Vicky; Ng, Edward; Chan, Cecilia; Givoni, Baruch

    2012-01-01

    This paper presents the findings of an outdoor thermal comfort study conducted in Hong Kong using longitudinal experiments—an alternative approach to conventional transverse surveys. In a longitudinal experiment, the thermal sensations of a relatively small number of subjects over different environmental conditions are followed and evaluated. This allows an exploration of the effects of changing climatic conditions on thermal sensation, and thus can provide information that is not possible to acquire through the conventional transverse survey. The paper addresses the effects of changing wind and solar radiation conditions on thermal sensation. It examines the use of predicted mean vote (PMV) in the outdoor context and illustrates the use of an alternative thermal index—physiological equivalent temperature (PET). The paper supports the conventional assumption that thermal neutrality corresponds to thermal comfort. Finally, predictive formulas for estimating outdoor thermal sensation are presented as functions of air temperature, wind speed, solar radiation intensity and absolute humidity. According to the formulas, for a person in light clothing sitting under shade on a typical summer day in Hong Kong where the air temperature is about 28°C and relative humidity about 80%, a wind speed of about 1.6 m/s is needed to achieve neutral thermal sensation.

  18. Outdoor thermal comfort study in a sub-tropical climate: a longitudinal study based in Hong Kong.

    PubMed

    Cheng, Vicky; Ng, Edward; Chan, Cecilia; Givoni, Baruch

    2012-01-01

    This paper presents the findings of an outdoor thermal comfort study conducted in Hong Kong using longitudinal experiments--an alternative approach to conventional transverse surveys. In a longitudinal experiment, the thermal sensations of a relatively small number of subjects over different environmental conditions are followed and evaluated. This allows an exploration of the effects of changing climatic conditions on thermal sensation, and thus can provide information that is not possible to acquire through the conventional transverse survey. The paper addresses the effects of changing wind and solar radiation conditions on thermal sensation. It examines the use of predicted mean vote (PMV) in the outdoor context and illustrates the use of an alternative thermal index--physiological equivalent temperature (PET). The paper supports the conventional assumption that thermal neutrality corresponds to thermal comfort. Finally, predictive formulas for estimating outdoor thermal sensation are presented as functions of air temperature, wind speed, solar radiation intensity and absolute humidity. According to the formulas, for a person in light clothing sitting under shade on a typical summer day in Hong Kong where the air temperature is about 28°C and relative humidity about 80%, a wind speed of about 1.6 m/s is needed to achieve neutral thermal sensation.

  19. An experimental phantom study of the effect of gadolinium-based MR contrast agents on PET attenuation coefficients and PET quantification in PET-MR imaging: application to cardiac studies.

    PubMed

    O' Doherty, Jim; Schleyer, Paul

    2017-12-01

    Simultaneous cardiac perfusion studies are an increasing trend in PET-MR imaging. During dynamic PET imaging, the introduction of gadolinium-based MR contrast agents (GBCA) at high concentrations during a dual injection of GBCA and PET radiotracer may cause increased attenuation effects of the PET signal, and thus errors in quantification of PET images. We thus aimed to calculate the change in linear attenuation coefficient (LAC) of a mixture of PET radiotracer and increasing concentrations of GBCA in solution and furthermore, to investigate if this change in LAC produced a measurable effect on the image-based PET activity concentration when attenuation corrected by three different AC strategies. We performed simultaneous PET-MR imaging of a phantom in a static scenario using a fixed activity of 40 MBq [18 F]-NaF, water, and an increasing GBCA concentration from 0 to 66 mM (based on an assumed maximum possible concentration of GBCA in the left ventricle in a clinical study). This simulated a range of clinical concentrations of GBCA. We investigated two methods to calculate the LAC of the solution mixture at 511 keV: (1) a mathematical mixture rule and (2) CT imaging of each concentration step and subsequent conversion to LAC at 511 keV. This comparison showed that the ranges of LAC produced by both methods are equivalent with an increase in LAC of the mixed solution of approximately 2% over the range of 0-66 mM. We then employed three different attenuation correction methods to the PET data: (1) each PET scan at a specific millimolar concentration of GBCA corrected by its corresponding CT scan, (2) each PET scan corrected by a CT scan with no GBCA present (i.e., at 0 mM GBCA), and (3) a manually generated attenuation map, whereby all CT voxels in the phantom at 0 mM were replaced by LAC = 0.1 cm -1 . All attenuation correction methods (1-3) were accurate to the true measured activity concentration within 5%, and there were no trends in image-based activity concentrations upon increasing the GBCA concentration of the solution. The presence of high GBCA concentration (representing a worst-case scenario in dynamic cardiac studies) in solution with PET radiotracer produces a minimal effect on attenuation-corrected PET quantification.

  20. Preparation of Hybrid Nanoparticle Nucleating Agents and Their Effects on the Crystallization Behavior of Poly(ethylene terephthalate)

    PubMed Central

    Han, Zhenzhen; Wang, Yao; Wang, Jiuxing; Wang, Shichao; Zhuang, Hongwei; Liu, Jixian; Huang, Linjun; Wang, Yanxin; Wang, Wei; Belfiore, Laurence A.; Tang, Jianguo

    2018-01-01

    In this research contribution, the primary objective was to enhance the crystallization behavior of poly(ethylene terephthalate) (PET). To accomplish this tack, three kinds of new nucleating agents SiO2-diethylene glycol-LMPET (PET-3), SiO2-triethylene glycol–LMPET(PET-4) and SiO2-tetraethylene glycol-LMPET (PET-5) nucleating agents were prepared via grafting different oligomers (diethylene glycol; triethylene glycol and tetraethylene glycol) to the surface of nano-SiO2 and then linking to the low molecular weight poly(ethylene terephthalate) (LMPET). These nano-particle nucleating agents facilitated the crystallization of PET. Differential scanning calorimetry (DSC) studies of the composites that pure PET blended with PET-3, PET-4 and PET-5 indicated that the longer ethoxy segment in the nucleating agents exhibited (i) higher degrees of crystallinity; (ii) faster rates of crystallization; and (iii) higher crystallization temperatures. The Jeziorny method was employed to analyze the non-isothermal crystallization kinetics of the composites. These works demonstrated that the PET-3, PET-4 and PET-5 were attractive nucleating agents for poly(ethylene terephthalate), and the longer the chain length of the ethoxy segment in the nucleating agents, the more efficient the nucleation effect. PMID:29641456

  1. Feasibility Study of an Axially Extendable Multiplex Cylinder PET

    NASA Astrophysics Data System (ADS)

    Yoshida, Eiji; Hirano, Yoshiyuki; Tashima, Hideaki; Inadama, Naoko; Nishikido, Fumihiko; Murayama, Hideo; Ito, Hiroshi; Yamaya, Taiga

    2013-10-01

    Current clinical PET scanners have a 15-22 cm axial field-of-view (FOV). These scanners image the whole body using six or more bed positions. We designed an axially extendable multiplex cylinder (AEMC) PET scanner to provide high versatility for clinical and research studies using semiconductor photo-sensor based, depth-of-interaction (DOI) detectors. Since silicon-photomultipliers (Si-PMs) have high gain like conventional photomultiplier tubes and a compact design, the Si-PM-based detector is particularly expected to enable various new detector arrangements. The AEMC-PET scanner consists of multiple independent and laminated detector rings using the DOI detectors. The AEMC-PET scanner can extend the axial FOV as each stacked detector ring can be slid sideways. When this PET scanner is used for the four-layer DOI detector, its minimum axial FOV is 24 cm and its maximum crystal thickness is 3 cm. On the other hand, the axial FOV can be extended to 96 cm when laminated detector rings are slid sideways, but the crystal thickness must be 1/4 of 3 cm. In this work, we evaluated performance characteristics of the PET scanner with a variable axial FOV using Monte Carlo simulation. From the simulation of the 180-cm line source, the 96-cm axial FOV was found to have two-fold better sensitivity compared to the 24-cm axial FOV. For extension of the axial FOV, scatter and attenuation of oblique lines-of-response reduced the yield of true coincidences, but effects of scatter and attenuation were small. Conclusive results were obtained showing the 52.8-cm axial FOV yielded an increase in the noise equivalent count rate of approximately 30% relative to the 24-cm axial FOV. We expect the designed AEMC-PET scanner will provide high versatility in applications such as for measuring whole-body tracer uptakes while keeping the continuous axial FOV; as well, the scan time for static images will be reduced for a comparable number of detectors as conventional PET scanners.

  2. An evaluation of the migration of antimony from polyethylene terephthalate (PET) plastic used for bottled drinking water.

    PubMed

    Chapa-Martínez, C A; Hinojosa-Reyes, L; Hernández-Ramírez, A; Ruiz-Ruiz, E; Maya-Treviño, L; Guzmán-Mar, J L

    2016-09-15

    The leaching of antimony (Sb) from polyethylene terephthalate (PET) bottling material was assessed in twelve brands of bottled water purchased in Mexican supermarkets by atomic fluorescence spectrometry with a hydride generation system (HG-AFS). Dowex® 1X8-100 ion-exchange resin was used to preconcentrate trace amounts of Sb in water samples. Migration experiments from the PET bottle material were performed in water according to the following storage conditions: 1) temperature (25 and 75°C), 2) pH (3 and 7) and 3) exposure time (5 and 15days), using ultrapure water as a simulant for liquid foods. The test conditions were studied by a 2(3) factorial experimental design. The Sb concentration measured in the PET packaging materials varied between 73.0 and 111.3mg/kg. The Sb concentration (0.28-2.30μg/L) in all of the PET bottled drinking water samples examined at the initial stage of the study was below the maximum contaminant level of 5μg/L prescribed by European Union (EU) regulations. The parameters studied (pH, temperature, and storage time) significantly affected the release of Sb, with temperature having the highest positive significant effect within the studied experimental domain. The highest Sb concentration leached from PET containers was in water samples at pH7 stored at 75°C for a period of 5days. The extent of Sb leaching from the PET ingredients for different brands of drinking water can differ by as much as one order of magnitude in experiments conducted under the worst-case conditions. The chronic daily intake (CDI) caused by the release of Sb in one brand exceeded the Environmental Protection Agency (USEPA) regulated CDI value of 400ng/kg/day, with values of 514.3 and 566.2ng/kg/day for adults and children. Thus, the appropriate selection of the polymer used for the production of PET bottles seems to ensure low Sb levels in water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Flexible Al-doped ZnO films grown on PET substrates using linear facing target sputtering for flexible OLEDs

    NASA Astrophysics Data System (ADS)

    Jeong, Jin-A.; Shin, Hyun-Su; Choi, Kwang-Hyuk; Kim, Han-Ki

    2010-11-01

    We report the characteristics of flexible Al-doped zinc oxide (AZO) films prepared by a plasma damage-free linear facing target sputtering (LFTS) system on PET substrates for use as a flexible transparent conducting electrode in flexible organic light-emitting diodes (OLEDs). The electrical, optical and structural properties of LFTS-grown flexible AZO electrodes were investigated as a function of dc power. We obtained a flexible AZO film with a sheet resistance of 39 Ω/squ and an average transmittance of 84.86% in the visible range although it was sputtered at room temperature without activation of the Al dopant. Due to the effective confinement of the high-density plasma between the facing AZO targets, the AZO film was deposited on the PET substrate without plasma damage and substrate heating caused by bombardment of energy particles. Moreover, the flexible OLED fabricated on the AZO/PET substrate showed performance similar to the OLED fabricated on a ITO/PET substrate in spite of a lower work function. This indicates that LFTS is a promising plasma damage-free and low-temperature sputtering technique for deposition of flexible and indium-free AZO electrodes for use in cost-efficient flexible OLEDs.

  4. A Rapid Method for Deposition of Sn-Doped GaN Thin Films on Glass and Polyethylene Terephthalate Substrates

    NASA Astrophysics Data System (ADS)

    Pat, Suat; Özen, Soner; Korkmaz, Şadan

    2018-01-01

    We report the influence of Sn doping on microstructure, surface, and optical properties of GaN thin films deposited on glass and polyethylene terephthalate (PET) substrate. Sn-doped GaN thin films have been deposited by thermionic vacuum arc (TVA) at low temperature. TVA is a rapid deposition technology for thin film growth. Surface and optical properties of the thin films were presented. Grain size, height distribution, roughness values were determined. Grain sizes were calculated as 20 nm and 13 nm for glass and PET substrates, respectively. Nano crystalline forms were shown by field emission scanning electron microscopy. Optical band gap values were determined by optical methods and photoluminescence measurement. The optical band gap values of Sn doped GaN on glass and PET were determined to be approximately ˜3.40 eV and ˜3.47 eV, respectively. As a result, TVA is a rapid and low temperature deposition technology for the Sn doped GaN deposited on glass and PET substrate.

  5. Future water availability in North African dams simulated by high-resolution regional climate models

    NASA Astrophysics Data System (ADS)

    Tramblay, Yves; Jarlan, Lionel; Hanich, Lahoucine; Somot, Samuel

    2016-04-01

    In North Africa, the countries of Morocco, Algeria and Tunisia are already experiencing water scarcity and a strong interannual variability of precipitation. To better manage their existing water resources, several dams and reservoirs have been built on most large river catchments. The objective of this study is to provide quantitative scenarios of future changes in water availability for the 47 major dams and reservoirs catchments located in North Africa. An ensemble of regional climate models (RCM) with a spatial resolution of 12km, driven by different general circulation models (GCM), from the EuroCORDEX experiment have been considered to analyze the projected changes on temperature, precipitation and potential evapotranspiration (PET) for two scenarios (RCP4.5 and RCP8.5) and two time horizons (2040-2065 and 2065-2090). PET is estimated from RCM outputs either with the FAO-Penman-Monteith (PM) equation, requiring air temperature, relative humidity, net radiation and wind, or with the Hargreave Samani (HS) equation, requiring only air temperature. The water balance is analyzed by comparing the climatic demand and supply of water, considering that for most of these catchments groundwater storage is negligible over long time periods. Results indicated a future temperature increase for all catchments between +1.8° and +4.2°, depending on the emission scenario and the time period considered. Precipitation is projected to decrease between -14% to -27%, mainly in winter and spring, with a strong East to West gradient. PET computed from PM or HS formulas provided very similar estimates and projections, ranging between +7% to +18%. Changes in PET are mostly driven by rising temperatures and are greatest during dry summer months than for the wet winter season. Therefore the increased PET has a lower impact than declining precipitation on future water availability, which is expected to decrease by -19% to -33% on average.

  6. Satellite-derived potential evapotranspiration for distributed hydrologic runoff modeling

    NASA Astrophysics Data System (ADS)

    Spies, R. R.; Franz, K. J.; Bowman, A.; Hogue, T. S.; Kim, J.

    2012-12-01

    Distributed models have the ability of incorporating spatially variable data, especially high resolution forcing inputs such as precipitation, temperature and evapotranspiration in hydrologic modeling. Use of distributed hydrologic models for operational streamflow prediction has been partially hindered by a lack of readily available, spatially explicit input observations. Potential evapotranspiration (PET), for example, is currently accounted for through PET input grids that are based on monthly climatological values. The goal of this study is to assess the use of satellite-based PET estimates that represent the temporal and spatial variability, as input to the National Weather Service (NWS) Hydrology Laboratory Research Distributed Hydrologic Model (HL-RDHM). Daily PET grids are generated for six watersheds in the upper Mississippi River basin using a method that applies only MODIS satellite-based observations and the Priestly Taylor formula (MODIS-PET). The use of MODIS-PET grids will be tested against the use of the current climatological PET grids for simulating basin discharge. Gridded surface temperature forcing data are derived by applying the inverse distance weighting spatial prediction method to point-based station observations from the Automated Surface Observing System (ASOS) and Automated Weather Observing System (AWOS). Precipitation data are obtained from the Climate Prediction Center's (CPC) Climatology-Calibrated Precipitation Analysis (CCPA). A-priori gridded parameters for the Sacramento Soil Moisture Accounting Model (SAC-SMA), Snow-17 model, and routing model are initially obtained from the Office of Hydrologic Development and further calibrated using an automated approach. The potential of the MODIS-PET to be used in an operational distributed modeling system will be assessed with the long-term goal of promoting research to operations transfers and advancing the science of hydrologic forecasting.

  7. Thermal Imaging Is a Noninvasive Alternative to PET/CT for Measurement of Brown Adipose Tissue Activity in Humans

    PubMed Central

    Law, James; Morris, David E.; Izzi-Engbeaya, Chioma; Salem, Victoria; Coello, Christopher; Robinson, Lindsay; Jayasinghe, Maduka; Scott, Rebecca; Gunn, Roger; Rabiner, Eugenii; Tan, Tricia; Dhillo, Waljit S.; Bloom, Stephen; Budge, Helen

    2018-01-01

    Obesity and its metabolic consequences are a major cause of morbidity and mortality. Brown adipose tissue (BAT) utilizes glucose and free fatty acids to produce heat, thereby increasing energy expenditure. Effective evaluation of human BAT stimulators is constrained by the current standard method of assessing BAT—PET/CT—as it requires exposure to high doses of ionizing radiation. Infrared thermography (IRT) is a potential noninvasive, safe alternative, although direct corroboration with PET/CT has not been established. Methods: IRT and 18F-FDG PET/CT data from 8 healthy men subjected to water-jacket cooling were directly compared. Thermal images were geometrically transformed to overlay PET/CT-derived maximum intensity projection (MIP) images from each subject, and the areas with the most intense temperature and glucose uptake within the supraclavicular regions were compared. Relationships between supraclavicular temperatures (TSCR) from IRT and the metabolic rate of glucose uptake (MR(gluc)) from PET/CT were determined. Results: Glucose uptake on MR(gluc)MIP was found to correlate positively with a change in TSCR relative to a reference region (r2 = 0.721; P = 0.008). Spatial overlap between areas of maximal MR(gluc)MIP and maximal TSCR was 29.5% ± 5.1%. Prolonged cooling, for 60 min, was associated with a further TSCR rise, compared with cooling for 10 min. Conclusion: The supraclavicular hotspot identified on IRT closely corresponded to the area of maximal uptake on PET/CT-derived MR(gluc)MIP images. Greater increases in relative TSCR were associated with raised glucose uptake. IRT should now be considered a suitable method for measuring BAT activation, especially in populations for whom PET/CT is not feasible, practical, or repeatable. PMID:28912148

  8. Activity of Tachykinin1-Expressing Pet1 Raphe Neurons Modulates the Respiratory Chemoreflex

    PubMed Central

    Corcoran, Andrea E.; Brust, Rachael D.; Chang, YoonJeung; Nattie, Eugene E.

    2017-01-01

    Homeostatic control of breathing, heart rate, and body temperature relies on circuits within the brainstem modulated by the neurotransmitter serotonin (5-HT). Mounting evidence points to specialized neuronal subtypes within the serotonergic neuronal system, borne out in functional studies, for the modulation of distinct facets of homeostasis. Such functional differences, read out at the organismal level, are likely subserved by differences among 5-HT neuron subtypes at the cellular and molecular levels, including differences in the capacity to coexpress other neurotransmitters such as glutamate, GABA, thyrotropin releasing hormone, and substance P encoded by the Tachykinin-1 (Tac1) gene. Here, we characterize in mice a 5-HT neuron subtype identified by expression of Tac1 and the serotonergic transcription factor gene Pet1, referred to as the Tac1-Pet1 neuron subtype. Transgenic cell labeling showed Tac1-Pet1 soma resident largely in the caudal medulla. Chemogenetic [clozapine-N-oxide (CNO)-hM4Di] perturbation of Tac1-Pet1 neuron activity blunted the ventilatory response of the respiratory CO2 chemoreflex, which normally augments ventilation in response to hypercapnic acidosis to restore normal pH and PCO2. Tac1-Pet1 axonal boutons were found localized to brainstem areas implicated in respiratory modulation, with highest density in motor regions. These findings demonstrate that the activity of a Pet1 neuron subtype with the potential to release both 5-HT and substance P is necessary for normal respiratory dynamics, perhaps via motor outputs that engage muscles of respiration and maintain airway patency. These Tac1-Pet1 neurons may act downstream of Egr2-Pet1 serotonergic neurons, which were previously established in respiratory chemoreception, but do not innervate respiratory motor nuclei. SIGNIFICANCE STATEMENT Serotonin (5-HT) neurons modulate physiological processes and behaviors as diverse as body temperature, respiration, aggression, and mood. Using genetic tools, we characterize a 5-HT neuron subtype defined by expression of Tachykinin1 and Pet1 (Tac1-Pet1 neurons), mapping soma localization to the caudal medulla primarily and axonal projections to brainstem motor nuclei most prominently, and, when silenced, observed blunting of the ventilatory response to inhaled CO2. Tac1-Pet1 neurons thus appear distinct from and contrast previously described Egr2-Pet1 neurons, which project primarily to chemosensory integration centers and are themselves chemosensitive. PMID:28073937

  9. Human Brown Adipose Tissue Temperature and Fat Fraction Are Related to Its Metabolic Activity.

    PubMed

    Koskensalo, Kalle; Raiko, Juho; Saari, Teemu; Saunavaara, Virva; Eskola, Olli; Nuutila, Pirjo; Saunavaara, Jani; Parkkola, Riitta; Virtanen, Kirsi A

    2017-04-01

    The metabolic activity of human brown adipose tissue (BAT) has been previously examined using positron emission tomography (PET). The aim of this study was to use proton magnetic resonance spectroscopy (1H MRS) to investigate whether the temperature and the fat fraction (FF) of BAT and white adipose tissue (WAT) are associated with BAT metabolic activity determined by deoxy-2-18F-fluoro-d-glucose (18F-FDG)-PET. Ten healthy subjects (four women, six men; 25 to 45 years of age) were studied using PET-magnetic resonance imaging during acute cold exposure and at ambient room temperature. BAT and subcutaneous WAT 1H MRS were measured. The tissue temperature and the FF were derived from the spectra. Tissue metabolic activity was studied through glucose uptake using dynamic FDG PET scanning during cold exposure. A 2-hour hyperinsulinemic euglycemic clamp was performed on eight subjects. The metabolic activity of BAT associated directly with the heat production capacity and inversely with the FF of the tissue. In addition, the lipid-burning capacity of BAT associated with whole-body insulin sensitivity. During cold exposure, the FF of BAT was lower than at room temperature, and cold-induced FF of BAT associated inversely with high-density lipoprotein and directly with low-density lipoprotein cholesterol. Both 1H MRS-derived temperature and FF are promising methods to study BAT activity noninvasively. The association between the lipid-burning capacity of BAT and whole-body insulin sensitivity emphasizes the role of BAT in glucose handling. Furthermore, the relation of FF to high-density lipoprotein and low-density lipoprotein cholesterol suggests that BAT has a role in lipid clearance, thus protecting tissues from excess lipid load. Copyright © 2017 Endocrine Society

  10. Acid-base properties of 2-phenethyldithiocarbamoylacetic acid, an antitumor agent

    NASA Astrophysics Data System (ADS)

    Novozhilova, N. E.; Kutina, N. N.; Petukhova, O. A.; Kharitonov, Yu. Ya.

    2013-07-01

    The acid-base properties of the 2-phenethyldithiocarbamoylacetic acid (PET) substance belonging to the class of isothiocyanates and capable of inhibiting the development of tumors on many experimental models were studied. The acidity and hydrolysis constants of the PET substance in ethanol, acetone, aqueous ethanol, and aqueous acetone solutions were determined from the data of potentiometric (pH-metric) titration of ethanol and acetone solutions of PET with aqueous solidum hydroxide at room temperature.

  11. Comparison of Monte Carlo simulated and measured performance parameters of miniPET scanner

    NASA Astrophysics Data System (ADS)

    Kis, S. A.; Emri, M.; Opposits, G.; Bükki, T.; Valastyán, I.; Hegyesi, Gy.; Imrek, J.; Kalinka, G.; Molnár, J.; Novák, D.; Végh, J.; Kerek, A.; Trón, L.; Balkay, L.

    2007-02-01

    In vivo imaging of small laboratory animals is a valuable tool in the development of new drugs. For this purpose, miniPET, an easy to scale modular small animal PET camera has been developed at our institutes. The system has four modules, which makes it possible to rotate the whole detector system around the axis of the field of view. Data collection and image reconstruction are performed using a data acquisition (DAQ) module with Ethernet communication facility and a computer cluster of commercial PCs. Performance tests were carried out to determine system parameters, such as energy resolution, sensitivity and noise equivalent count rate. A modified GEANT4-based GATE Monte Carlo software package was used to simulate PET data analogous to those of the performance measurements. GATE was run on a Linux cluster of 10 processors (64 bit, Xeon with 3.0 GHz) and controlled by a SUN grid engine. The application of this special computer cluster reduced the time necessary for the simulations by an order of magnitude. The simulated energy spectra, maximum rate of true coincidences and sensitivity of the camera were in good agreement with the measured parameters.

  12. Migration of antimony from PET bottles into beverages: determination of the activation energy of diffusion and migration modelling compared with literature data.

    PubMed

    Welle, F; Franz, R

    2011-01-01

    Plastics bottles made from polyethylene terephthalate (PET) are increasingly used for soft drinks, mineral water, juices and beer. In this study a literature review is presented concerning antimony levels found both in PET materials as well as in foods and food simulants. On the other hand, 67 PET samples from the European bottle market were investigated for their residual antimony concentrations. A mean value of 224 ± 32 mg kg(-1) was found, the median was 220 mg kg(-1). Diffusion coefficients for antimony in PET bottle materials were experimentally determined at different temperature between 105 and 150°C. From these data, the activation energy of diffusion for antimony species from the PET bottle wall into beverages and food simulants was calculated. The obtained value of 189 kJ mol(-1) was found to be in good agreement with published data on PET microwave trays (184 kJ mol(-1)). Based on these results, the migration of antimony into beverages was predicted by mathematical migration modelling for different surface/volume ratios and antimony bottle wall concentrations. The results were compared with literature data as well as international legal limits and guidelines values for drinking water and the migration limit set from food packaging legislation. It was concluded that antimony levels in beverages due to migration from PET bottles manufactured according to the state of the art can never reach or exceed the European-specific migration limit of 40 microg kg(-1). Maximum migration levels caused by room-temperature storage even after 3 years will never be essentially higher than 2.5 microg kg(-1) and in any case will be below the European limit of 5 microg kg(-1) for drinking water. The results of this study confirm that the exposure of the consumer by antimony migration from PET bottles into beverages and even into edible oils reaches approximately 1% of the current tolerable daily intake (TDI) established by World Health Organisation (WHO). Having substantiated such low antimony levels in PET-bottled beverages, the often addressed question on oestrogenic effects caused by antimony from PET bottles appears to be groundless.

  13. Incidental detection of colorectal lesions by FDG PET/CT scans in melanoma patients.

    PubMed

    Young, Christopher J; Zahid, Assad; Choy, Ian; Thompson, John F; Saw, Robyn P M

    2017-11-01

    Increased use of PET/CT scans in oncology patients has raised detection of Colorectal incidentalomas (CIs). The frequency and diagnostic outcomes of identifying these lesions in melanoma patients have not previously been studied. This studies primary objective was to determine the prevalence of CIs found on PET/CT scans in melanoma patients. The secondary objectives were to correlate the PET/CT findings with the pathology found at colonoscopy, and identify which patients were referred for colonoscopy. A retrospective analysis of patients identified from the prospectively collected research database of Melanoma Institute Australia. 2509 patients with melanoma underwent PET/CT scans between 2001 and 2013. The prevalence of CIs, the correlation of lesions, and the survival of patients who underwent colonoscopy versus patients who did not were analyzed. The prevalence of CIs in melanoma patients who had PET/CT scans was 3.2%. Forty-five of the 81 (56%) patients with CIs underwent colonoscopy. Of these, premalignant or malignant disease was found in 58%. Patients with previous metastatic melanoma were significantly less likely to be referred for colonoscopy. Patients undergoing colonoscopy had significantly better survival, as did those without previous distant metastases before the CIs were found, and those without any metastases at the time the CIs were found. These factors were not significant on multivariate analysis. The prevalence of incidental colorectal lesions identified on PET/CT scans in melanoma patients was found to be equivalent to that in the general cancer population. Patients undergoing colonoscopy had better survival than those who did not. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  14. PET Performance Evaluation of an MR-Compatible PET Insert

    PubMed Central

    Wu, Yibao; Catana, Ciprian; Farrell, Richard; Dokhale, Purushottam A.; Shah, Kanai S.; Qi, Jinyi; Cherry, Simon R.

    2010-01-01

    A magnetic resonance (MR) compatible positron emission tomography (PET) insert has been developed in our laboratory for simultaneous small animal PET/MR imaging. This system is based on lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiode (PSAPD) photodetectors. The PET performance of this insert has been measured. The average reconstructed image spatial resolution was 1.51 mm. The sensitivity at the center of the field of view (CFOV) was 0.35%, which is comparable to the simulation predictions of 0.40%. The average photopeak energy resolution was 25%. The scatter fraction inside the MRI scanner with a line source was 12% (with a mouse-sized phantom and standard 35 mm Bruker 1H RF coil), 7% (with RF coil only) and 5% (without phantom or RF coil) for an energy window of 350–650 keV. The front-end electronics had a dead time of 390 ns, and a trigger extension dead time of 7.32 μs that degraded counting rate performance for injected doses above ~0.75 mCi (28 MBq). The peak noise-equivalent count rate (NECR) of 1.27 kcps was achieved at 290 μCi (10.7 MBq). The system showed good imaging performance inside a 7-T animal MRI system; however improvements in data acquisition electronics and reduction of the coincidence timing window are needed to realize improved NECR performance. PMID:21072320

  15. Differences between near-surface equivalent temperature and temperature trends for the Eastern United States. Equivalent temperature as an alternative measure of heat content

    USGS Publications Warehouse

    Davey, C.A.; Pielke, R.A.; Gallo, K.P.

    2006-01-01

    There is currently much attention being given to the observed increase in near-surface air temperatures during the last century. The proper investigation of heating trends, however, requires that we include surface heat content to monitor this aspect of the climate system. Changes in heat content of the Earth's climate are not fully described by temperature alone. Moist enthalpy or, alternatively, equivalent temperature, is more sensitive to surface vegetation properties than is air temperature and therefore more accurately depicts surface heating trends. The microclimates evident at many surface observation sites highlight the influence of land surface characteristics on local surface heating trends. Temperature and equivalent temperature trend differences from 1982-1997 are examined for surface sites in the Eastern U.S. Overall trend differences at the surface indicate equivalent temperature trends are relatively warmer than temperature trends in the Eastern U.S. Seasonally, equivalent temperature trends are relatively warmer than temperature trends in winter and are relatively cooler in the fall. These patterns, however, vary widely from site to site, so local microclimate is very important. ?? 2006 Elsevier B.V. All rights reserved.

  16. Evaluation of outdoor human thermal sensation of local climate zones based on long-term database

    NASA Astrophysics Data System (ADS)

    Unger, János; Skarbit, Nóra; Gál, Tamás

    2018-02-01

    This study gives a comprehensive picture on the diurnal and seasonal general outdoor human thermal sensation levels in different urban quarters based on long-term (almost 3 years) data series from urban and rural areas of Szeged, Hungary. It is supplemented with a case study dealing with an extreme heat wave period which is more and more frequent in the last decades in the study area. The intra-urban comparison is based on a thermal aspect classification of the surface, namely, the local climate zone (LCZ) system, on an urban meteorological station network and on the utilization of the physiologically equivalent temperature (PET) comfort index with categories calibrated to the local population. The selected stations represent sunlit areas well inside the LCZ areas. The results show that the seasonal and annual average magnitudes of the thermal load exerted by LCZs in the afternoon and evening follow their LCZ numbers. It is perfectly in line with the LCZ concept originally concentrating only on air temperature ( T air) differences between the zones. Our results justified the subdivision of urban areas into LCZs and give significant support to the application possibilities of the LCZ concept as a broader term covering different thermal phenomena.

  17. A Maximum NEC Criterion for Compton Collimation to Accurately Identify True Coincidences in PET

    PubMed Central

    Chinn, Garry; Levin, Craig S.

    2013-01-01

    In this work, we propose a new method to increase the accuracy of identifying true coincidence events for positron emission tomography (PET). This approach requires 3-D detectors with the ability to position each photon interaction in multi-interaction photon events. When multiple interactions occur in the detector, the incident direction of the photon can be estimated using the Compton scatter kinematics (Compton Collimation). If the difference between the estimated incident direction of the photon relative to a second, coincident photon lies within a certain angular range around colinearity, the line of response between the two photons is identified as a true coincidence and used for image reconstruction. We present an algorithm for choosing the incident photon direction window threshold that maximizes the noise equivalent counts of the PET system. For simulated data, the direction window removed 56%–67% of random coincidences while retaining > 94% of true coincidences from image reconstruction as well as accurately extracted 70% of true coincidences from multiple coincidences. PMID:21317079

  18. What is the best way to diagnose and stage malignant pleural mesothelioma?

    PubMed

    Zahid, Imran; Sharif, Sumera; Routledge, Tom; Scarci, Marco

    2011-02-01

    A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was which diagnostic modality [computed tomography (CT), positron emission tomography (PET), combination PET/CT and magnetic resonance imaging (MRI)] provides the best diagnostic and staging information in patients with malignant pleural mesothelioma (MPM). Overall, 61 papers were found using the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results are tabulated. We conclude that fluorodeoxyglucose (FDG)-PET is superior to MRI and CT but inferior to PET-CT, in terms of diagnostic specificity, sensitivity and staging of MPM. Four studies reported outcomes using FDG-PET to diagnose MPM. PET diagnosed MPM with high sensitivity (92%) and specificity (87.9%). Mean standardised uptake value (SUV) was higher in malignant than benign disease (4.91 vs. 1.41, P<0.0001). Lymph node metastases were detected with higher accuracy (80% vs. 66.7%) compared to extrathoracic disease. Three studies assessed the utility of PET-CT to diagnose MPM. Mean SUV was higher in malignant than benign disease (6.5 vs. 0.8, P<0.001). MPM was diagnosed with high sensitivity (88.2%), specificity (92.9%) and accuracy (88.9%). PET-CT had low sensitivity for stage N2 (38%) and T4 (67%) disease. CT-guided needle biopsy definitively diagnosed MPM after just one biopsy (100% vs. 9%) much more often than a 'blind' approach. CT had a lower success rate (92% vs. 100%) than thoracoscopic pleural biopsy but was equivalent to MRI in terms of detection of lymph node metastases (P=0.85) and visceral pleural tumour (P=0.64). CT had a lower specificity for stage II (77% vs. 100%, P<0.01) and stage III (75% vs. 100%, P<0.01) disease compared to PET-CT. Overall, the high specificity and sensitivity rates seen with open pleural biopsy make it a superior diagnostic modality to CT, MRI or PET for diagnosing patients with MPM.

  19. Aridity changes in the Tibetan Plateau in a warming climate

    DOE PAGES

    Gao, Yanhong; Li, Xia; Leung, Lai-Yung R.; ...

    2015-03-10

    Desertification in the Tibetan Plateau (TP) has drawn increasing attention in the recent decades. It has been postulated as a consequence of climate aridity due to the observed warming. This study quantifies the aridity changes in the TP and attributes the changes to different climatic factors. Using the ratio of P/PET (precipitation to potential evapotranspiration) as an aridity index to indicate changes in dryness and wetness in a given area, P/PET was calculated using observed records at 83 stations in the TP, with PET calculated using the Penman–Monteith (PM) algorithm. Spatial and temporal changes of P/PET in 1979-2011 are analyzed.more » Results show that stations located in the arid and semi-arid northwestern TP are becoming significantly wetter and stations in the semi-humid southeastern TP are becoming drier, though not significantly, in the recent three decades. The aridity change patterns are significantly correlated with precipitation, sunshine duration and diurnal temperature range changes at confidence level of 99.9% from two-tail t-test. Temporal correlations also confirm the significant correlation between aridity changes with the three variables, with precipitation being the most dominant driver of P/PET changes at interannual time scale. PET changes are insignificant but negatively correlated with P/PET in the cold season. In the warm season, however, correlation between PET changes and P/PET changes are significant at confidence level of 99.9% when the cryosphere melts near the surface. Significant correlation between wind speed changes and aridity changes occurs in limited locations and months. Consistency in the climatology pattern and linear trends in surface air temperature and precipitation calculated using station data, gridded data, and nearest grid-to-stations for the TP average and across sub-basins indicate the robustness of the trends despite the large spatial heterogeneity in the TP that challenge climate monitoring.« less

  20. Supraclavicular skin temperature and BAT activity in lean healthy adults.

    PubMed

    van der Lans, Anouk A J J; Vosselman, Maarten J; Hanssen, Mark J W; Brans, Boudewijn; van Marken Lichtenbelt, Wouter D

    2016-01-01

    The 'gold standard' for measuring brown adipose tissue (BAT) in humans is [(18)F]FDG-PET/CT-imaging. With this technique subjects are exposed to ionizing radiation and are therefore limited in the number of scans that can be performed. We investigated the relation between supraclavicular skin temperatures and BAT activity values using a strictly temperature-controlled air-cooling protocol. Data of 36 male subjects was analyzed. BAT activity was evaluated by [(18)F]FDG-PET/CT-imaging and skin temperature was measured by means of wireless temperature sensors. Supraclavicular skin temperature dropped less compared to skin temperatures at other sites (all P values <0.01). A significant positive correlation was found between the change in supraclavicular skin temperature with BAT activity (R (2) 0.23), and the change in supraclavicular skin temperature and non-shivering thermogenesis (R (2) 0.18, both P values <0.01). The correlations indicate that supraclavicular skin temperature (changes) can potentially be used as a qualitative measure of BAT activity and BAT thermogenesis.

  1. Microclimatic effects of planted hydroponic structures in urban environment: measurements and simulations

    NASA Astrophysics Data System (ADS)

    Katsoulas, N.; Antoniadis, D.; Tsirogiannis, I. L.; Labraki, E.; Bartzanas, T.; Kittas, C.

    2017-05-01

    The objectives of this effort was to study the effect of vertical (green wall) and horizontal (pergola) green structures on the microclimate conditions of the building surroundings and estimate the thermal perception and heat stress conditions near the two structures. The experimental data were used to validate the results simulated by the recent version (V4.0 preview III) of ENVI-met software which was used to simulate the effect of different design parameters of a pergola and a green façade on microclimate and heat stress conditions. Further aim is to use these results for better design of green structures. The microclimate measurements were carried out in real scale structures (hydroponic pergola and hydroponic green wall) at the Kostakii Campus of the Technological Education Institute of Epirus (Arta, Greece). The validation results showed a very good agreement between measured and simulated values of air temperature, with Tair,sim = 0.98 Tair,meas in the Empty atrium and Tair,sim = 0.99 Tair,meas in the Atrium with pergola, with a determination coefficient R 2 of 0.98 and 0.93, respectively. The model was used to predict the effects of green structures on air temperature (Tair), relative humidity (RH), and mean radiant temperature (Tmrt). The output values of these parameters were used as input data in the RayMan pro (V 2.1) model for estimating the physiologically equivalent temperature (PET) of different case scenarios. The average daytime value of simulated air temperature in the atrium for the case without and with pergola during three different days was 29.2 and 28.9 °C while the corresponding measured values were 29.7 and 29.2 °C. The results showed that compared to the case with no pergola in the atrium, covering 100% the atrium area with a planted pergola reduced at the hottest part of the day Tmrt and PET values by 29.4 and 17.9 °C, respectively. Although the values of air temperature (measured and simulated) were not greatly affected by the presence of a green wall, the most important effect of green wall to the building wall is the reduction of solar radiation behind the green wall. This reduction leads to a significant reduction (about 8 °C) of building surface temperature behind the green wall and accordingly to a reduction of the energy load of the building.

  2. Application of single- and dual-energy CT brain tissue segmentation to PET monitoring of proton therapy

    NASA Astrophysics Data System (ADS)

    Berndt, Bianca; Landry, Guillaume; Schwarz, Florian; Tessonnier, Thomas; Kamp, Florian; Dedes, George; Thieke, Christian; Würl, Matthias; Kurz, Christopher; Ganswindt, Ute; Verhaegen, Frank; Debus, Jürgen; Belka, Claus; Sommer, Wieland; Reiser, Maximilian; Bauer, Julia; Parodi, Katia

    2017-03-01

    The purpose of this work was to evaluate the ability of single and dual energy computed tomography (SECT, DECT) to estimate tissue composition and density for usage in Monte Carlo (MC) simulations of irradiation induced β + activity distributions. This was done to assess the impact on positron emission tomography (PET) range verification in proton therapy. A DECT-based brain tissue segmentation method was developed for white matter (WM), grey matter (GM) and cerebrospinal fluid (CSF). The elemental composition of reference tissues was assigned to closest CT numbers in DECT space (DECTdist). The method was also applied to SECT data (SECTdist). In a validation experiment, the proton irradiation induced PET activity of three brain equivalent solutions (BES) was compared to simulations based on different tissue segmentations. Five patients scanned with a dual source DECT scanner were analyzed to compare the different segmentation methods. A single magnetic resonance (MR) scan was used for comparison with an established segmentation toolkit. Additionally, one patient with SECT and post-treatment PET scans was investigated. For BES, DECTdist and SECTdist reduced differences to the reference simulation by up to 62% when compared to the conventional stoichiometric segmentation (SECTSchneider). In comparison to MR brain segmentation, Dice similarity coefficients for WM, GM and CSF were 0.61, 0.67 and 0.66 for DECTdist and 0.54, 0.41 and 0.66 for SECTdist. MC simulations of PET treatment verification in patients showed important differences between DECTdist/SECTdist and SECTSchneider for patients with large CSF areas within the treatment field but not in WM and GM. Differences could be misinterpreted as PET derived range shifts of up to 4 mm. DECTdist and SECTdist yielded comparable activity distributions, and comparison of SECTdist to a measured patient PET scan showed improved agreement when compared to SECTSchneider. The agreement between predicted and measured PET activity distributions was improved by employing a brain specific segmentation applicable to both DECT and SECT data.

  3. Performance of a PET Insert for High-Resolution Small-Animal PET/MRI at 7 Tesla.

    PubMed

    Stortz, Greg; Thiessen, Jonathan D; Bishop, Daryl; Khan, Muhammad Salman; Kozlowski, Piotr; Retière, Fabrice; Schellenberg, Graham; Shams, Ehsan; Zhang, Xuezhu; Thompson, Christopher J; Goertzen, Andrew L; Sossi, Vesna

    2018-03-01

    We characterize a compact MR-compatible PET insert for simultaneous preclinical PET/MRI. Although specifically designed with the strict size constraint to fit inside the 114-mm inner diameter of the BGA-12S gradient coil used in the BioSpec 70/20 and 94/20 series of small-animal MRI systems, the insert can easily be installed in any appropriate MRI scanner or used as a stand-alone PET system. Methods: The insert consists of a ring of 16 detector-blocks each made from depth-of-interaction-capable dual-layer-offset arrays of cerium-doped lutetium-yttrium oxyorthosilicate crystals read out by silicon photomultiplier arrays. Scintillator crystal arrays are made from 22 × 10 and 21 × 9 crystals in the bottom and top layers, respectively, with respective layer thicknesses of 6 and 4 mm, arranged with a 1.27-mm pitch, resulting in a useable field of view 28 mm long and about 55 mm wide. Results: Spatial resolution ranged from 1.17 to 1.86 mm full width at half maximum in the radial direction from a radial offset of 0-15 mm. With a 300- to 800-keV energy window, peak sensitivity was 2.2% and noise-equivalent count rate from a mouse-sized phantom at 3.7 MBq was 11.1 kcps and peaked at 20.8 kcps at 14.5 MBq. Phantom imaging showed that features as small as 0.7 mm could be resolved. 18 F-FDG PET/MR images of mouse and rat brains showed no signs of intermodality interference and could excellently resolve substructures within the brain. Conclusion: Because of excellent spatial resolvability and lack of intermodality interference, this PET insert will serve as a useful tool for preclinical PET/MR. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  4. Radiation Dosimetry of Whole-Body Dual-Tracer 18F-FDG and 11C-Acetate PET/CT for Hepatocellular Carcinoma.

    PubMed

    Liu, Dan; Khong, Pek-Lan; Gao, Yiming; Mahmood, Usman; Quinn, Brian; St Germain, Jean; Xu, X George; Dauer, Lawrence T

    2016-06-01

    Combined whole-body dual-tracer ((18)F-FDG and (11)C-acetate) PET/CT is increasingly used for staging hepatocellular carcinoma, with only limited studies investigating the radiation dosimetry data of these scans. The aim of the study was to characterize the radiation dosimetry of combined whole-body dual-tracer PET/CT protocols. Consecutive adult patients with hepatocellular carcinoma who underwent whole-body dual-tracer PET/CT scans were retrospectively reviewed with institutional review board approval. OLINDA/EXM 1.1 was used to estimate patient-specific internal dose exposure in each organ. Biokinetic models for (18)F-FDG and (11)C-acetate as provided by ICRP (International Commission on Radiological Protection) publication 106 were used. Standard reference phantoms were modified to more closely represent patient-specific organ mass. With patient-specific parameters, organ equivalent doses from each CT series were estimated using VirtualDose. Dosimetry capabilities for tube current modulation protocols were applied by integrating with the latest anatomic realistic models. Effective dose was calculated using ICRP publication 103 tissue-weighting coefficients for adult male and female, respectively. Fourteen scans were evaluated (12 men, 2 women; mean age ± SD, 60 ± 19.48 y). The patient-specific effective dose from (18)F-FDG and (11)C-acetate was 6.08 ± 1.49 and 1.56 ± 0.47 mSv, respectively, for male patients and 6.62 ± 1.38 and 1.79 ± 0.12 mSV, respectively, for female patients. The patient-specific effective dose of the CT component, which comprised 2 noncontrast whole-body scans, to male and female patients was 21.20 ± 8.94 and 14.79 ± 3.35 mSv, respectively. Thus, the total effective doses of the combined whole-body dual-tracer PET/CT studies for male and female patients were 28.84 ± 10.18 and 23.19 ± 4.61 mSv, respectively. Patient-specific parameters allow for more accurate estimation of organ equivalent doses. Considering the substantial radiation dose incurred, judicious medical justification is required with every whole-body dual-tracer PET/CT referral. Although radiation risks may have less impact for the population with cancer because of their reduced life expectancy, the information is of interest and relevant for both justification, to evaluate risk/benefit, and protocol optimization. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  5. Flotation separation of polyvinyl chloride and polyethylene terephthalate plastics combined with surface modification for recycling.

    PubMed

    Wang, Chongqing; Wang, Hui; Fu, Jiangang; Zhang, Lingling; Luo, Chengcheng; Liu, Younian

    2015-11-01

    Surface modification with potassium permanganate (KMnO4) solution was developed for separation of polyvinyl chloride (PVC) and polyethylene terephthalate (PET) waste plastics. The floatability of PVC decreases with increasing of KMnO4 concentration, treatment time, temperature and stirring rate, while that of PET is unaffected. Fourier transform infrared (FT-IR) analysis confirms that mechanism of surface modification may be due to oxidization reactions occurred on PVC surface. The optimum conditions are KMnO4 concentration 1.25 mM/L, treatment time 50 min, temperature 60°C, stirring rate 300 r/min, frother concentration 17.5 g/L and flotation time 1 min. PVC and PET with different particle sizes were separated efficiently through two-stage flotation. Additionally, after ultrasonic assisted surface modification, separation of PVC and PET with different mass ratios was obtained efficiently through one-stage flotation. The purity and the recovery of the obtained products after flotation separation are up to 99.30% and 99.73%, respectively. A flotation process was designed for flotation separation of PVC and PET plastics combined with surface modification. This study provides technical insights into physical separation of plastic wastes for recycling industry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Significance of the impact of motion compensation on the variability of PET image features

    NASA Astrophysics Data System (ADS)

    Carles, M.; Bach, T.; Torres-Espallardo, I.; Baltas, D.; Nestle, U.; Martí-Bonmatí, L.

    2018-03-01

    In lung cancer, quantification by positron emission tomography/computed tomography (PET/CT) imaging presents challenges due to respiratory movement. Our primary aim was to study the impact of motion compensation implied by retrospectively gated (4D)-PET/CT on the variability of PET quantitative parameters. Its significance was evaluated by comparison with the variability due to (i) the voxel size in image reconstruction and (ii) the voxel size in image post-resampling. The method employed for feature extraction was chosen based on the analysis of (i) the effect of discretization of the standardized uptake value (SUV) on complementarity between texture features (TF) and conventional indices, (ii) the impact of the segmentation method on the variability of image features, and (iii) the variability of image features across the time-frame of 4D-PET. Thirty-one PET-features were involved. Three SUV discretization methods were applied: a constant width (SUV resolution) of the resampling bin (method RW), a constant number of bins (method RN) and RN on the image obtained after histogram equalization (method EqRN). The segmentation approaches evaluated were 40% of SUVmax and the contrast oriented algorithm (COA). Parameters derived from 4D-PET images were compared with values derived from the PET image obtained for (i) the static protocol used in our clinical routine (3D) and (ii) the 3D image post-resampled to the voxel size of the 4D image and PET image derived after modifying the reconstruction of the 3D image to comprise the voxel size of the 4D image. Results showed that TF complementarity with conventional indices was sensitive to the SUV discretization method. In the comparison of COA and 40% contours, despite the values not being interchangeable, all image features showed strong linear correlations (r  >  0.91, p\\ll 0.001 ). Across the time-frames of 4D-PET, all image features followed a normal distribution in most patients. For our patient cohort, the compensation of tumor motion did not have a significant impact on the quantitative PET parameters. The variability of PET parameters due to voxel size in image reconstruction was more significant than variability due to voxel size in image post-resampling. In conclusion, most of the parameters (apart from the contrast of neighborhood matrix) were robust to the motion compensation implied by 4D-PET/CT. The impact on parameter variability due to the voxel size in image reconstruction and in image post-resampling could not be assumed to be equivalent.

  7. Current technological advances in magnetic resonance with critical impact for clinical diagnosis and therapy.

    PubMed

    Runge, Val M

    2013-12-01

    The last 5 years of technological advances with major impact on clinical magnetic resonance (MR) are discussed, with greater emphasis on those that are most recent. These developments have already had a critical positive effect on clinical diagnosis and therapy and presage continued rapid improvements for the next 5 years. This review begins with a discussion of 2 topics that encompass the breadth of MR, in terms of anatomic applications, contrast media, and MR angiography. Subsequently, innovations are discussed by anatomic category, picking the areas with the greatest development, starting with the brain, moving forward to the liver and kidney, and concluding with the musculoskeletal system, breast, and prostate. Two final topics are then considered, which will likely, with time, become independent major fields in their own right, interventional MR and MR positron emission tomography (PET).The next decade will bring a new generation of MR contrast media, with research focused on substantial improvements (>100-fold) in relaxivity (contrast effect), thus providing greater efficacy, safety, and tissue targeting. Magnetic resonance angiography will see major advances because of the use of compressed sensing, in terms of spatial and temporal resolution, with movement away from nondynamic imaging. The breadth of available techniques and tissue contrast has greatly expanded in brain imaging, benefiting both from the introduction of new basic categories of imaging techniques, such as readout-segmented echo planar imaging and 3D fast spin echo imaging with variable flip angles, and from new refinements specific to anatomic areas, such as double inversion recovery and MP2RAGE. Liver imaging has benefited from the development of techniques to easily and rapidly assess lipid, and will see, overall, a marked improvement in the next 5 years from new techniques on the verge of clinical introduction, such as controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA), with a substantial impact on both spatial resolution and scan time. Renal MR is benefiting from the application of blood-oxygen-level-dependent imaging, providing an assessment of renal function critical for the evaluation of chronic kidney disease. Techniques to reduce metal artifact are a major focus of development in musculoskeletal MR and are critical for the ever-increasing postsurgical and implant patient population, leading to markedly improved imaging of tissue adjacent to metal and diagnosis of infection, prosthesis loosening, and postsurgical complications such as fracture. In breast MR, scan techniques are continuing to evolve, and the impact of this examination on screening for and evaluation and treatment of breast carcinoma is substantial with continued expansion of indications. Prostate MR has benefited from multiparametric imaging and the application of diffusion-weighted imaging, the latter technique also now applied more generally in body imaging, with a substantial clinical impact, in particular for the detection of tumor lymph nodes. Interventional MR is still early in its development, although well established in many centers, possessing great potential in comparison with computed tomography (CT) because of superior soft-tissue contrast, real-time multiplanar imaging guidance and monitoring, the availability of temperature mapping, and the lack of ionizing radiation. And last but not least, MR-PET is in its infancy, with the first round of clinical units installed in the past 2 years and early clinical experience showing equivalence and, in some instances, superiority to PET-CT. As with the field of MR itself, which began when CT was already an established modality, MR-PET will likely, in the next decade, become an equivalent modality to PET-CT, if not begin to supplant the latter modality.

  8. Meniscus-force-mediated layer transfer technique using single-crystalline silicon films with midair cavity: Application to fabrication of CMOS transistors on plastic substrates

    NASA Astrophysics Data System (ADS)

    Sakaike, Kohei; Akazawa, Muneki; Nakagawa, Akitoshi; Higashi, Seiichiro

    2015-04-01

    A novel low-temperature technique for transferring a silicon-on-insulator (SOI) layer with a midair cavity (supported by narrow SiO2 columns) by meniscus force has been proposed, and a single-crystalline Si (c-Si) film with a midair cavity formed in dog-bone shape was successfully transferred to a poly(ethylene terephthalate) (PET) substrate at its heatproof temperature or lower. By applying this proposed transfer technique, high-performance c-Si-based complementary metal-oxide-semiconductor (CMOS) transistors were successfully fabricated on the PET substrate. The key processes are the thermal oxidation and subsequent hydrogen annealing of the SOI layer on the midair cavity. These processes ensure a good MOS interface, and the SiO2 layer works as a “blocking” layer that blocks contamination from PET. The fabricated n- and p-channel c-Si thin-film transistors (TFTs) on the PET substrate showed field-effect mobilities of 568 and 103 cm2 V-1 s-1, respectively.

  9. Kleptoplast Regulation by an Antarctic Dinoflagellate

    NASA Astrophysics Data System (ADS)

    Gast, R. J.; Hehenberger, E.; Keeling, P.

    2016-02-01

    We are studying the evolutionary history and expression of plastid- targeted genes in an Antarctic dinoflagellate that steals chloroplasts from the haptophyte, Phaeocystis. Our project seeks to determine whether the kleptoplastidic dinoflagellate utilizes ancestral plastid proteins to regulate its stolen plastid, and how their transcription is related to environmental factors that are relevant to the Southern Ocean environment (temperature and light). To accomplish our goals, we have utilized high throughput transciptome analysis and RNA-Seq experiments of the dinoflagellate and Phaeocystis. Analysis of the dinoflagellate transcriptome has revealed complete mevalonic acid-independent and heme plastid-associated pathways as well as petF and petH transcripts with peridinin-plastid targeting sequences. In contrast, the proteins psaE, petJ, petC show similarity to non-Phaeocystis haptophyte homologs in their respective trees, and potentially carry haptophyte transit peptides. Anaylsis of RNA-Seq temperature and light experiments for the dinoflagellate indicate that there are significant differences in gene expression under the different environmental conditions, and we are in the process of identifying the genes associated with these changes. This work will help us to understand the environmental success of this alternative nutritional strategy.

  10. Quantitative and Visual Assessments toward Potential Sub-mSv or Ultrafast FDG PET Using High-Sensitivity TOF PET in PET/MRI.

    PubMed

    Behr, Spencer C; Bahroos, Emma; Hawkins, Randall A; Nardo, Lorenzo; Ravanfar, Vahid; Capbarat, Emily V; Seo, Youngho

    2018-06-01

    Newer high-performance time-of-flight (TOF) positron emission tomography (PET) systems have the capability to preserve diagnostic image quality with low count density, while maintaining a high raw photon detection sensitivity that would allow for a reduction in injected dose or rapid data acquisition. To assess this, we performed quantitative and visual assessments of the PET images acquired using a highly sensitive (23.3 cps/kBq) large field of view (25-cm axial) silicon photomultiplier (SiPM)-based TOF PET (400-ps timing resolution) integrated with 3 T-MRI in comparison to PET images acquired on non-TOF PET/x-ray computed tomography (CT) systems. Whole-body 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) PET/CT was acquired for 15 patients followed by whole body PET/magnetic resonance imaging (MRI) with an average injected dose of 325 ± 84 MBq. The PET list mode data from PET/MRI were reconstructed using full datasets (4 min/bed) and reduced datasets (2, 1, 0.5, and 0.25 min/bed). Qualitative assessment between PET/CT and PET/MR images were made. A Likert-type scale between 1 and 5, 1 for non-diagnostic, 3 equivalent to PET/CT, and 5 superior quality, was used. Maximum and mean standardized uptake values (SUV max and SUV mean ) of normal tissues and lesions detected were measured and compared. Mean visual assessment scores were 3.54 ± 0.32, 3.62 ± 0.38, and 3.69 ± 0.35 for the brain and 3.05 ± 0.49, 3.71 ± 0.45, and 4.14 ± 0.44 for the whole-body maximum intensity projections (MIPs) for 1, 2, and 4 min/bed PET/MR images, respectively. The SUV mean values for normal tissues were lower and statistically significant for images acquired at 4, 2, 1, 0.5, and 0.25 min/bed on the PET/MR, with values of - 18 ± 28 % (p < 0.001), - 16 ± 29 % (p = 0.001), - 16 ± 31 % (p = 0.002), - 14 ± 35 % (p < 0.001), and - 13 ± 34 % (p = 0.002), respectively. SUV max and SUV peak values of all lesions were higher and statistically significant (p < 0.05) for 4, 2, 1, 0.50, and 0.25 min/bed PET/MR datasets. High-sensitivity TOF PET showed comparable but still better visual image quality even at a much reduced activity in comparison to lower-sensitivity non-TOF PET. Our data translates to a seven times reduction in either injection dose for the same time or total scan time for the same injected dose. This "ultra-sensitivity" PET system provides a path to clinically acceptable extremely low-dose FDG PET studies (e.g., sub 1 mCi injection or sub-mSv effective dose) or PET studies as short as 1 min/bed (e.g., 6 min of total scan time) to cover whole body without compromising diagnostic performance.

  11. Bradycardia in serotonin-deficient Pet-1−/− mice: influence of respiratory dysfunction and hyperthermia over the first 2 postnatal weeks

    PubMed Central

    Cummings, Kevin J.; Li, Aihua; Deneris, Evan S.

    2010-01-01

    Neonatal rodents deficient in medullary serotonin neurons have respiratory instability and enhanced spontaneous bradycardias. This study asks if, in Pet-1−/− mice over development: 1) the respiratory instability leads to hypoxia; 2) greater bradycardia is related to the degree of hypoxia or concomitant hypopnea; and 3) hyperthermia exacerbates bradycardias. Pet-1+/+, Pet-1+/−, and Pet-1−/− mice [postnatal days (P) 4–5, P11–12, P14–15] were held at normal body temperature (Tb) and were then made 2°C hypo- and hyperthermic. Using a pneumotach-mask system with ECG, we measured heart rate, metabolic rate (V̇o2), and ventilation. We also calculated indexes for apnea-induced hypoxia (total hypoxia: apnea incidence × O2 consumed during apnea = μl·g−1·min−1) and bradycardia (total bradycardia: bradycardia incidence × magnitude = beats missed/min). Resting heart rate was significantly lower in all Pet-1−/− animals, irrespective of Tb. At P4–5, Pet-1−/− animals had approximately four- to eightfold greater total bradycardia (P < 0.001), owing to an approximately two- to threefold increase in bradycardia magnitude and a near doubling in bradycardia incidence. Pet-1−/− animals had a significantly reduced V̇o2 at all Tb; thus there was no genotype effect on total hypoxia. At P11–12, total bradycardia was nearly threefold greater in hyperthermic Pet-1−/− animals compared with controls (P < 0.01). In both genotypes, bradycardia magnitude was positively related to the degree of hypopnea (P = 0.02), but there was no genotype effect on degree of hypopnea or total hypoxia. At P14–15, genotype had no effect on total bradycardia, but Pet-1−/− animals had up to seven times more total hypoxia (P < 0.001), owing to longer and more frequent apneas and a normalized V̇o2. We infer from these data that 1) Pet-1−/− neonates are probably not hypoxic from respiratory dysfunction until P14–15; 2) neither apnea-related hypoxia nor greater hypopnea contribute to the enhanced bradycardias of Pet-1−/− neonates from approximately P4 to approximately P12; and 3) an enhancement of a temperature-sensitive reflex may contribute to the greater bradycardia in hyperthermic Pet-1−/− animals at approximately P12. PMID:20421636

  12. Activity of Tachykinin1-Expressing Pet1 Raphe Neurons Modulates the Respiratory Chemoreflex.

    PubMed

    Hennessy, Morgan L; Corcoran, Andrea E; Brust, Rachael D; Chang, YoonJeung; Nattie, Eugene E; Dymecki, Susan M

    2017-02-15

    Homeostatic control of breathing, heart rate, and body temperature relies on circuits within the brainstem modulated by the neurotransmitter serotonin (5-HT). Mounting evidence points to specialized neuronal subtypes within the serotonergic neuronal system, borne out in functional studies, for the modulation of distinct facets of homeostasis. Such functional differences, read out at the organismal level, are likely subserved by differences among 5-HT neuron subtypes at the cellular and molecular levels, including differences in the capacity to coexpress other neurotransmitters such as glutamate, GABA, thyrotropin releasing hormone, and substance P encoded by the Tachykinin-1 ( Tac1 ) gene. Here, we characterize in mice a 5-HT neuron subtype identified by expression of Tac1 and the serotonergic transcription factor gene Pet1 , referred to as the Tac1-Pet1 neuron subtype. Transgenic cell labeling showed Tac1-Pet1 soma resident largely in the caudal medulla. Chemogenetic [clozapine -N- oxide (CNO)-hM4Di] perturbation of Tac1-Pet1 neuron activity blunted the ventilatory response of the respiratory CO 2 chemoreflex, which normally augments ventilation in response to hypercapnic acidosis to restore normal pH and PCO 2 Tac1-Pet1 axonal boutons were found localized to brainstem areas implicated in respiratory modulation, with highest density in motor regions. These findings demonstrate that the activity of a Pet1 neuron subtype with the potential to release both 5-HT and substance P is necessary for normal respiratory dynamics, perhaps via motor outputs that engage muscles of respiration and maintain airway patency. These Tac1-Pet1 neurons may act downstream of Egr2-Pet1 serotonergic neurons, which were previously established in respiratory chemoreception, but do not innervate respiratory motor nuclei. SIGNIFICANCE STATEMENT Serotonin (5-HT) neurons modulate physiological processes and behaviors as diverse as body temperature, respiration, aggression, and mood. Using genetic tools, we characterize a 5-HT neuron subtype defined by expression of Tachykinin1 and Pet1 ( Tac1-Pet1 neurons), mapping soma localization to the caudal medulla primarily and axonal projections to brainstem motor nuclei most prominently, and, when silenced, observed blunting of the ventilatory response to inhaled CO 2 Tac1-Pet1 neurons thus appear distinct from and contrast previously described Egr2-Pet1 neurons, which project primarily to chemosensory integration centers and are themselves chemosensitive. Copyright © 2017 the authors 0270-6474/17/371807-13$15.00/0.

  13. Dataset on daytime outdoor thermal comfort for Belo Horizonte, Brazil.

    PubMed

    Hirashima, Simone Queiroz da Silveira; Assis, Eleonora Sad de; Nikolopoulou, Marialena

    2016-12-01

    This dataset describe microclimatic parameters of two urban open public spaces in the city of Belo Horizonte, Brazil; physiological equivalent temperature (PET) index values and the related subjective responses of interviewees regarding thermal sensation perception and preference and thermal comfort evaluation. Individuals and behavioral characteristics of respondents were also presented. Data were collected at daytime, in summer and winter, 2013. Statistical treatment of this data was firstly presented in a PhD Thesis ("Percepção sonora e térmica e avaliação de conforto em espaços urbanos abertos do município de Belo Horizonte - MG, Brasil" (Hirashima, 2014) [1]), providing relevant information on thermal conditions in these locations and on thermal comfort assessment. Up to now, this data was also explored in the article "Daytime Thermal Comfort in Urban Spaces: A Field Study in Brazil" (Hirashima et al., in press) [2]. These references are recommended for further interpretation and discussion.

  14. Electrically controllable twisted-coiled artificial muscle actuators using surface-modified polyester fibers

    NASA Astrophysics Data System (ADS)

    Park, Jungwoo; Yoo, Ji Wang; Seo, Hee Won; Lee, Youngkwan; Suhr, Jonghwan; Moon, Hyungpil; Koo, Ja Choon; Ryeol Choi, Hyouk; Hunt, Robert; Kim, Kwang Jin; Kim, Soo Hyun; Nam, Jae-Do

    2017-03-01

    As a new class of thermally activated actuators based on polymeric fibers, we investigated polyethylene terephthalate (PET) yarns for the development of a twisted-coiled polymer fiber actuator (TCA). The PET yarn TCA exhibited the maximum linear actuation up to 8.9% by external heating at above the glass transition temperature, 160 °C-180 °C. The payload of the actuator was successfully correlated with the preload and training-load conditions by an empirical equation. Furthermore, the PET-based TCA was electrically driven by Joule heating after the PET surface was metallization with silver. For the fast and precise control of PET yarn TCA, electroless silver plating was conducted to form electrical conductive layers on the PET fiber surface. The silver plated PET-based TCA was tested by Joule heating and the tensile actuation was increased up to 12.1% (6 V) due to the enhanced surface hardness and slippage of PET fibers. Overall, silver plating of the polymeric yarn provided a fast actuation speed and enhanced actuation performance of the TCA actuator by Joule heating, providing a great potential for being used in artificial muscle for biomimetic machines including robots, industrial actuators and powered exoskeletons.

  15. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms.

    PubMed

    Bieniosek, Matthew F; Lee, Brian J; Levin, Craig S

    2015-10-01

    Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial "Micro Deluxe" phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. This work shows that 3D printed phantoms can be functionally equivalent to commercially available phantoms. They are a viable option for quickly distributing and fabricating low cost, customized phantoms.

  16. Spatial uncertainty analysis: Propagation of interpolation errors in spatially distributed models

    USGS Publications Warehouse

    Phillips, D.L.; Marks, D.G.

    1996-01-01

    In simulation modelling, it is desirable to quantify model uncertainties and provide not only point estimates for output variables but confidence intervals as well. Spatially distributed physical and ecological process models are becoming widely used, with runs being made over a grid of points that represent the landscape. This requires input values at each grid point, which often have to be interpolated from irregularly scattered measurement sites, e.g., weather stations. Interpolation introduces spatially varying errors which propagate through the model We extended established uncertainty analysis methods to a spatial domain for quantifying spatial patterns of input variable interpolation errors and how they propagate through a model to affect the uncertainty of the model output. We applied this to a model of potential evapotranspiration (PET) as a demonstration. We modelled PET for three time periods in 1990 as a function of temperature, humidity, and wind on a 10-km grid across the U.S. portion of the Columbia River Basin. Temperature, humidity, and wind speed were interpolated using kriging from 700- 1000 supporting data points. Kriging standard deviations (SD) were used to quantify the spatially varying interpolation uncertainties. For each of 5693 grid points, 100 Monte Carlo simulations were done, using the kriged values of temperature, humidity, and wind, plus random error terms determined by the kriging SDs and the correlations of interpolation errors among the three variables. For the spring season example, kriging SDs averaged 2.6??C for temperature, 8.7% for relative humidity, and 0.38 m s-1 for wind. The resultant PET estimates had coefficients of variation (CVs) ranging from 14% to 27% for the 10-km grid cells. Maps of PET means and CVs showed the spatial patterns of PET with a measure of its uncertainty due to interpolation of the input variables. This methodology should be applicable to a variety of spatially distributed models using interpolated inputs.

  17. Imaging modalities in the diagnosis of pancreatic adenocarcinoma: A systematic review and meta-analysis of sensitivity, specificity and diagnostic accuracy.

    PubMed

    Toft, James; Hadden, William J; Laurence, Jerome M; Lam, Vincent; Yuen, Lawrence; Janssen, Anna; Pleass, Henry

    2017-07-01

    Pancreatic cancer, primarily pancreatic ductal adenocarcinoma (PDAC), accounts for 2.4% of cancer diagnoses and 5.8% of cancer death annually. Early diagnoses can improve 5-year survival in PDAC. The aim of this systematic review was to determine the sensitivity, specificity and diagnostic accuracy values for MRI, CT, PET&PET/CT, EUS and transabdominal ultrasound (TAUS) in the diagnosis of PDAC. A systematic review was undertaken to identify studies reporting sensitivity, specificity and/or diagnostic accuracy for the diagnosis of PDAC with MRI, CT, PET, EUS or TAUS. Proportional meta-analysis was performed for each modality. A total of 5399 patients, 3567 with PDAC, from 52 studies were included. The sensitivity, specificity and diagnostic accuracy were 93% (95% CI=88-96), 89% (95% CI=82-94) and 90% (95% CI=86-94) for MRI; 90% (95% CI=87-93), 87% (95% CI=79-93) and 89% (95% CI=85-93) for CT; 89% (95% CI=85-93), 70% (95% CI=54-84) and 84% (95% CI=79-89) for PET; 91% (95% CI=87-94), 86% (95% CI=81-91) and 89% (95% CI=87-92) for EUS; and 88% (95% CI=86-90), 94% (95% CI=87-98) and 91% (95% C=87-93) for TAUS. This review concludes all modalities, except for PET, are equivalent within 95% confidence intervals for the diagnosis of PDAC. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Impact of high 131I-activities on quantitative 124I-PET

    NASA Astrophysics Data System (ADS)

    Braad, P. E. N.; Hansen, S. B.; Høilund-Carlsen, P. F.

    2015-07-01

    Peri-therapeutic 124 I-PET/CT is of interest as guidance for radioiodine therapy. Unfortunately, image quality is complicated by dead time effects and increased random coincidence rates from high 131 I-activities. A series of phantom experiments with clinically relevant 124 I/131 I-activities were performed on a clinical PET/CT-system. Noise equivalent count rate (NECR) curves and quantitation accuracy were determined from repeated scans performed over several weeks on a decaying NEMA NU-2 1994 cylinder phantom initially filled with 25 MBq 124 I and 1250 MBq 131 I. Six spherical inserts with diameters 10-37 mm were filled with 124 I (0.45 MBq ml-1 ) and 131 I (22 MBq ml-1 ) and placed inside the background of the NEMA/IEC torso phantom. Contrast recovery, background variability and the accuracy of scatter and attenuation corrections were assessed at sphere-to-background activity ratios of 20, 10 and 5. Results were compared to pure 124 I-acquisitions. The quality of 124 I-PET images in the presence of high 131 I-activities was good and image quantification unaffected except at very high count rates. Quantitation accuracy and contrast recovery were uninfluenced at 131 I-activities below 1000 MBq, whereas image noise was slightly increased. The NECR peaked at 550 MBq of 131 I, where it was 2.8 times lower than without 131 I in the phantom. Quantitative peri-therapeutic 124 I-PET is feasible.

  19. A PET Design Based on SiPM and Monolithic LYSO Crystals: Performance Evaluation

    NASA Astrophysics Data System (ADS)

    González, Antonio J.; Aguilar, Albert; Conde, Pablo; Hernández, Liczandro; Moliner, Laura; Vidal, Luis F.; Sánchez, Filomeno; Sánchez, Sebastián; Correcher, Carlos; Molinos, César; Barberá, Julio; Lankes, Konrad; Junge, Sven; Bruckbauer, Thomas; Bruyndonckx, Peter; Benlloch, Jose M.

    2016-10-01

    A new small animal PET based on SiPM and monolithic LYSO crystals has been developed. Eight detector modules form the PET ring, each mounting an array of 12 × 12 SiPMs coupled to a readout providing the summed signals of the pixels on each of the 12 rows and 12 columns of the SiPM array. This design makes it possible to accurately determine the centroid of the scintillation light distribution with about 1.6 mm full width at half maximum (FWHM) resolution without correction for the 1 mm source size, and the photon depth of interaction (DOI) with nearly 2 mm FWHM. This single ring PET system has a homogeneous spatial resolution across the entire 80 mm transaxial field of view (FOV) of about 1 mm FWHM. The noise equivalent count rate (NECR) peak is estimated to occur at around 39.2 MBq with a rate of approximately 82.7 kcps for the mouse-like phantom and 22 kcps at 48.1 MBq for the rat-like phantom. Following the NEMA protocol, the peak absolute sensitivity in the center of the FOV is 2.8% for a 30% peak energy window. A pilot test injecting NaF to a mouse of 20 grams is also presented. Finally, the PET ring has been tested in front of a high field 15.2 T Magnetic Resonance (MR). No significant variation on energy and spatial resolution across the FOV has been observed due to the presence of the magnetic field.

  20. Effects of storage temperature and time of antimony release from PET bottles into drinking water in China.

    PubMed

    Qiao, Fei; Lei, Kun; Li, Zicheng; Liu, Qing; Wei, Zhanliang; An, Lihui; Qi, Hongli; Cui, Song

    2018-01-01

    Antimony (Sb) concentrations were measured in 10 brands of PET bottled drinking water available in supermarkets in China. To simulate general storage habits based on market research, these PET bottles with drinking water were stored for 4 weeks in a lab or a car trunk during the summer. Although the PET package material of brand A had the lowest Sb level (142.71 ± 29.81 μg/g), it showed a significant increase in Sb concentrations when stored in both the car trunk and the lab. There was significant release of Sb from the PET bottles into the water following 24 h of incubation at ≥ 40 °C (40, 50, 60, and 70 °C), especially at 70 °C. The potential health risk of Sb release from PET bottles was calculated based on daily intake values and determined to be acceptable for consumers under normal storage conditions.

  1. Simulated responses of terrestrial aridity to black carbon and sulfate aerosols

    NASA Astrophysics Data System (ADS)

    Lin, L.; Gettelman, A.; Xu, Y.; Fu, Q.

    2016-01-01

    Aridity index (AI), defined as the ratio of precipitation to potential evapotranspiration (PET), is a measure of the dryness of terrestrial climate. Global climate models generally project future decreases of AI (drying) associated with global warming scenarios driven by increasing greenhouse gas and declining aerosols. Given their different effects in the climate system, scattering and absorbing aerosols may affect AI differently. Here we explore the terrestrial aridity responses to anthropogenic black carbon (BC) and sulfate (SO4) aerosols with Community Earth System Model simulations. Positive BC radiative forcing decreases precipitation averaged over global land at a rate of 0.9%/°C of global mean surface temperature increase (moderate drying), while BC radiative forcing increases PET by 1.0%/°C (also drying). BC leads to a global decrease of 1.9%/°C in AI (drying). SO4 forcing is negative and causes precipitation a decrease at a rate of 6.7%/°C cooling (strong drying). PET also decreases in response to SO4 aerosol cooling by 6.3%/°C cooling (contributing to moistening). Thus, SO4 cooling leads to a small decrease in AI (drying) by 0.4%/°C cooling. Despite the opposite effects on global mean temperature, BC and SO4 both contribute to the twentieth century drying (AI decrease). Sensitivity test indicates that surface temperature and surface available energy changes dominate BC- and SO4-induced PET changes.

  2. Recyclability of PET/WPI/PE Multilayer Films by Removal of Whey Protein Isolate-Based Coatings with Enzymatic Detergents.

    PubMed

    Cinelli, Patrizia; Schmid, Markus; Bugnicourt, Elodie; Coltelli, Maria Beatrice; Lazzeri, Andrea

    2016-06-14

    Multilayer plastic films provide a range of properties, which cannot be obtained from monolayer films but, at present, their recyclability is an open issue and should be improved. Research to date has shown the possibility of using whey protein as a layer material with the property of acting as an excellent barrier against oxygen and moisture, replacing petrochemical non-recyclable materials. The innovative approach of the present research was to achieve the recyclability of the substrate films by separating them, with a simple process compatible with industrial procedures, in order to promote recycling processes leading to obtain high value products that will beneficially impact the packaging and food industries. Hence, polyethyleneterephthalate (PET)/polyethylene (PE) multi-layer film was prepared based on PET coated with a whey protein layer, and then the previous structure was laminated with PE. Whey proteins, constituting the coating, can be degraded by enzymes so that the coating films can be washed off from the plastic substrate layer. Enzyme types, dosage, time, and temperature optima, which are compatible with procedures adopted in industrial waste recycling, were determined for a highly-efficient process. The washing of samples based on PET/whey and PET/whey/PE were efficient when performed with enzymatic detergent containing protease enzymes, as an alternative to conventional detergents used in recycling facilities. Different types of enzymatic detergents tested presented positive results in removing the protein layer from the PET substrate and from the PET/whey/PE multilayer films at room temperature. These results attested to the possibility of organizing the pre-treatment of the whey-based multilayer film by washing with different available commercial enzymatic detergents in order to separate PET and PE, thus allowing a better recycling of the two different polymers. Mechanical properties of the plastic substrate, such as stress at yield, stress and elongation at break, evaluated by tensile testing on films before and after cleaning, were are not significantly affected by washing with enzymatic detergents.

  3. Relationship between endobronchial ultrasound‐guided (EBUS)‐transbronchial needle aspiration utility and computed tomography staging, node size at EBUS, and positron emission tomography scan node standard uptake values: A retrospective analysis

    PubMed Central

    Marchand, Clare

    2017-01-01

    Background Endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) diagnoses and stages mediastinal lymph node pathology. This retrospective study determined the relationship between EBUS‐TBNA utility and non‐small cell lung cancer (NSCLC) stage, lymph node size, and positron emission tomography (PET) standard uptake values (SUV), and the utility of neck ultrasound in bulky mediastinal disease. Methods Data of 284 consecutive patients who had undergone EBUS‐TBNA was collected. Two hundred patients had suspected NSCLC, with 148 confirmed NSCLC cases. The diagnostic utility of EBUS‐TBNA was determined according to NSCLC stage, EBUS lymph node size, PET SUV, use in distal metastases, and mutation testing. The utility of neck ultrasound for N3 disease was calculated in patients with bulky mediastinal disease. Results EBUS‐TBNA was well tolerated with 97% sensitivity in distant metastatic disease, avoiding the need for distal metastases biopsy in 81% of cases. It had equivalent diagnostic accuracy in all NSCLC stages and in lymph nodes <10 mm, <20 mm or >20 mm (sensitivity >92% in all cases), with no mutation testing failures. EBUS‐TBNA had 33% sensitivity in PET indolent (SUV < 4) nodes and 79% sensitivity in PET active nodes (SUV > 4). EBUS‐TBNA diagnosed 12 cases of lymphoma without flow cytometry. Conclusions The use of EBUS‐TBNA meant that distant metastatic biopsy was avoided in 81% of cases, performing well irrespective of cancer stage, node size, and facilitating mutation testing. Neck ultrasound failed to detect N3 disease in patients with bulky mediastinal disease. EBUS‐TBNA had a sensitivity of 33% for metastases in PET negative nodes, highlighting PET limitations. PMID:28436173

  4. Microplastics co-gasification with biomass: Modelling syngas characteristics at low temperatures

    NASA Astrophysics Data System (ADS)

    Ramos, Ana; Tavares, Raquel; Rouboa, Abel

    2018-05-01

    To assess the syngas produced through the gasification of microplastics at low temperatures, distinct blends of polyethylene terephthalate (PET) with biomass (vine pruning) were modelled using Aspen Plus. Critical gasification parameters such as co-fuel mixture, temperature and hydrogen production were evaluated, under two different gasifier agents (air and O2). Results have shown that higher PET ratios and higher temperatures (< 1200 °C) lead to enhanced hydrogen yields, for both atmospheres. The calorific content was also seen to increase with growing temperatures, superior LHV being achieved for the mixture with less microplastics fraction (9.2 MJ/Nm3) for both air and O2 environments. A final high-quality syngas was achieved, the dominant requirement determining which parameter to optimize: on one hand, higher H2 contents were seen for the blend with higher microplastic fraction, and on the other higher LHV was achieved for the equimolar mixture.

  5. Mechanical Stability of Flexible Graphene-Based Displays.

    PubMed

    Anagnostopoulos, George; Pappas, Panagiotis-Nektarios; Li, Zheling; Kinloch, Ian A; Young, Robert J; Novoselov, Kostya S; Lu, Ching Yu; Pugno, Nicola; Parthenios, John; Galiotis, Costas; Papagelis, Konstantinos

    2016-08-31

    The mechanical behavior of a prototype touch panel display, which consists of two layers of CVD graphene embedded into PET films, is investigated in tension and under contact-stress dynamic loading. In both cases, laser Raman spectroscopy was employed to assess the stress transfer efficiency of the embedded graphene layers. The tensile behavior was found to be governed by the "island-like" microstructure of the CVD graphene, and the stress transfer efficiency was dependent on the size of graphene "islands" but also on the yielding behavior of PET at relatively high strains. Finally, the fatigue tests, which simulate real operation conditions, showed that the maximum temperature gradient developed at the point of "finger" contact after 80 000 cycles does not exceed the glass transition temperature of the PET matrix. The effect of these results on future product development and the design of new graphene-based displays are discussed.

  6. Mechanical Stability of Flexible Graphene-Based Displays

    PubMed Central

    2016-01-01

    The mechanical behavior of a prototype touch panel display, which consists of two layers of CVD graphene embedded into PET films, is investigated in tension and under contact-stress dynamic loading. In both cases, laser Raman spectroscopy was employed to assess the stress transfer efficiency of the embedded graphene layers. The tensile behavior was found to be governed by the “island-like” microstructure of the CVD graphene, and the stress transfer efficiency was dependent on the size of graphene “islands” but also on the yielding behavior of PET at relatively high strains. Finally, the fatigue tests, which simulate real operation conditions, showed that the maximum temperature gradient developed at the point of “finger” contact after 80 000 cycles does not exceed the glass transition temperature of the PET matrix. The effect of these results on future product development and the design of new graphene-based displays are discussed. PMID:27494211

  7. The variability of atmospheric equivalent temperature for radar altimeter range correction

    NASA Technical Reports Server (NTRS)

    Liu, W. Timothy; Mock, Donald

    1990-01-01

    Two sets of data were used to test the validity of the presently used approximation for radar altimeter range correction due to atmospheric water vapor. The approximation includes an assumption of constant atmospheric equivalent temperature. The first data set includes monthly, three-dimensional, gridded temperature and humidity fields over global oceans for a 10-year period, and the second is comprised of daily or semidaily rawinsonde data at 17 island stations for a 7-year period. It is found that the standard method underestimates the variability of the equivalent temperature, and the approximation could introduce errors of 2 cm for monthly means. The equivalent temperature is found to have a strong meridional gradient, and the highest temporal variabilities are found over western boundary currents. The study affirms that the atmospheric water vapor is a good predictor for both the equivalent temperature and the range correction. A relation is proposed to reduce the error.

  8. Development of a 3D Brain PET Scanner Using CdTe Semiconductor Detectors and Its First Clinical Application

    NASA Astrophysics Data System (ADS)

    Morimoto, Y.; Ueno, Y.; Takeuchi, W.; Kojima, S.; Matsuzaki, K.; Ishitsu, T.; Umegaki, K.; Kiyanagi, Y.; Kubo, N.; Katoh, C.; Shiga, T.; Shirato, H.; Tamaki, N.

    2011-10-01

    Targeting improved spatial resolution, a three-dimensional positron-emission-tomography (PET) scanner employing CdTe semiconductor detectors and using depth-of-interaction (DOI) information was developed, and its physical performance was evaluated. This PET scanner is the first to use semiconductor detectors dedicated to the human brain and head-and-neck region. Imaging performance of the scanner used for 18F -fluorodeoxy glucose (FDG) scans of phantoms and human brains was evaluated. The gantry of the scanner has a 35.0-cm-diameter patient port, the trans-axial field of view (FOV) is 31.0 cm, and the axial FOV is 24.6 cm. The energy resolution averaged over all detector channels and timing resolution were 4.1% and 6.8 ns (each in FWHM), respectively. Spatial resolution measured at the center of FOV was 2.3-mm FWHM-which is one of the best resolutions achieved by human PET scanners. Noise-equivalent count ratio (NEC2R) has a maximum in the energy window of 390 to 540 keV and is 36 kcps/Bq/cm3 at 3.7 kBq/cm3 . The sensitivity of the system according to NEMA 1994 was 25.9 cps/Bq/cm3. Scatter fraction of the scanner is 37% for the energy window of 390 to 540 keV and 23% for 450 to 540 keV. Images of a hot-rod phantom and images of brain glucose metabolism show that the structural accuracy of the images obtained with the semiconductor PET scanner is higher than that possible with a conventional Bismuth Germanium Oxide (BGO) PET scanner. In addition, the developed scanner permits better delineation of the head-and-neck cancer. These results show that the semiconductor PET scanner will play a major role in the upcoming era of personalized medicine.

  9. Gene Expression Patterns during Light and Dark Infection of Prochlorococcus by Cyanophage

    PubMed Central

    Chisholm, Sallie W.

    2016-01-01

    Cyanophage infecting the marine cyanobacteria Prochlorococcus and Synechococcus require light and host photosystem activity for optimal reproduction. Many cyanophages encode multiple photosynthetic electron transport (PET) proteins, which are presumed to maintain electron flow and produce ATP and NADPH for nucleotide biosynthesis and phage genome replication. However, evidence suggests phage augment NADPH production via the pentose phosphate pathway (PPP), thus calling into question the need for NADPH production by PET. Genes implicated in cyclic PET have since been identified in cyanophage genomes. It remains an open question which mode of PET, cyclic or linear, predominates in infected cyanobacteria, and thus whether the balance is towards producing ATP or NADPH. We sequenced transcriptomes of a cyanophage (P-HM2) and its host (Prochlorococcus MED4) throughout infection in the light or in the dark, and analyzed these data in the context of phage replication and metabolite measurements. Infection was robust in the light, but phage were not produced in the dark. Host gene transcripts encoding high-light inducible proteins and two terminal oxidases (plastoquinol terminal oxidase and cytochrome c oxidase)—implicated in protecting the photosynthetic membrane from light stress—were the most enriched in light but not dark infection. Among the most diminished transcripts in both light and dark infection was ferredoxin–NADP+ reductase (FNR), which uses the electron acceptor NADP+ to generate NADPH in linear photosynthesis. The phage gene for CP12, which putatively inhibits the Calvin cycle enzyme that receives NADPH from FNR, was highly expressed in light infection. Therefore, both PET production of NADPH and its consumption by carbon fixation are putatively repressed during phage infection in light. Transcriptomic evidence is thus consistent with cyclic photophosphorylation using oxygen as the terminal electron acceptor as the dominant mode of PET under infection, with ATP from PET and NADPH from the PPP producing the energy and reducing equivalents for phage nucleotide biosynthesis and replication. PMID:27788196

  10. Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

    PubMed Central

    Zargan, S.; Ghafarian, P.; Shabestani Monfared, A.; Sharafi, A.A.; Bakhshayeshkaram, M.; Ay, M.R.

    2017-01-01

    Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT and cyclotron center. Materials and Methods: 80 patients participated in this study. Thermoluminescence, electronic personal dosimeter and Geiger-Muller dosimeter were also utilized for measurement purpose. Results: The mean annual equivalent organ dose for scanning operator with regard to lens of eyes, thyroid, breast and finger according to mean±SD value, were 0.262±0.044, 0.256±0.046, 0.257±0.040 and 0.316±0.118, respectively. The maximum and minimum estimated annual whole body doses were observed for injector and the chemist group with values of (3.98±0.021) mSv/yr and (1.64±0.014) mSv/yr, respectively. The observed dose rates were 5.67 µSv/h in uptake room at the distance of 0.5 meter from the patient whereas the value 4.94 and 3.08 µSv/h were recorded close to patient’s head in PET/CT room and 3.5 meter from the reception desk. Conclusion: In this study, the injector staff and scanning operator received the first high level and second high level of radiation. This study confirmed that low levels of radiation dose were received by all radiation staff during PET/CT procedure using 18F-FDG due to efficient shielding and using trained radiation staff in PET/CT and cyclotron center of Masih Daneshvari hospital. PMID:28451574

  11. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    PubMed

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  12. Material and Structural Performance Evaluations of Hwangtoh Admixtures and Recycled PET Fiber-Added Eco-Friendly Concrete for CO2 Emission Reduction

    PubMed Central

    Koo, Bon-Min; Kim, Jang-Ho Jay; Kim, Sung-Bae; Mun, Sungho

    2014-01-01

    In order to reduce carbon dioxide (CO2) emissions and produce an eco-friendly construction material, a type of concrete that uses a minimal amount of cement, yet still retains equivalent properties to ordinary cement concrete, has been developed and studied all over the world. Hwangtoh, a type of red clay broadly deposited around the world, has traditionally been considered an eco-friendly construction material, with bonus advantages of having health and cost benefits. Presently, Hwangtoh is not commonly used as a modern construction material due to properties such as low strength and high rates of shrinkage cracking. Recent studies, however, have shown that Hwangtoh can be used as a mineral admixture to improve the strength of concrete. In addition, polyethylene terephthalate (PET) fibers recycled from PET bottle waste can be used to control shrinkage cracks in Hwangtoh concrete. Therefore, in this study, performance verification is conducted on newly developed Hwangtoh concrete mixed with short recycled PET fibers. The results show that Hwangtoh concrete has compressive strength, elastic modulus, and pH properties that are similar to these features in ordinary cement concrete. The properties of carbonation depth and creep strain of Hwangtoh concrete, however, are larger and smaller, respectively, than in ordinary cement concrete. According to flexural tests, reinforced concrete (RC) specimens cast with Hwangtoh admixtures (with and without PET fibers) possess similar or better capacities than ordinary RC specimens. The addition of PET fibers significantly improves the structural ductility of RC specimens under normal environmental conditions. However, the implementations of the concrete in aggressive environment must be carefully considered, since a previous study result indicates degradation of its durability performance in aggressive environments, such as seawater [1]. The results of this study validate the possibility of using eco-friendly Hwangtoh concrete reinforced with recycled PET fibers as a structural material for modern construction. PMID:28788171

  13. Performance Characteristics of a New LSO PET/CT Scanner With Extended Axial Field-of-View and PSF Reconstruction

    NASA Astrophysics Data System (ADS)

    Jakoby, Bjoern W.; Bercier, Yanic; Watson, Charles C.; Bendriem, Bernard; Townsend, David W.

    2009-06-01

    A new combined lutetium oxyorthosilicate (LSO) PET/CT scanner with an extended axial field-of-view (FOV) of 21.8 cm has been developed (Biograph TruePoint PET/CT with TrueV; Siemens Molecular Imaging) and introduced into clinical practice. The scanner includes the recently announced point spread function (PSF) reconstruction algorithm. The PET components incorporate four rings of 48 detector blocks, 5.4 cm times 5.4 cm in cross-section. Each block comprises a 13 times 13 matrix of 4 times 4 times 20 mm3 elements. Data are acquired with a 4.5 ns coincidence time window and an energy window of 425-650 keV. The physical performance of the new scanner has been evaluated according to the recently revised National Electrical Manufacturers Association (NEMA) NU 2-2007 standard and the results have been compared with a previous PET/CT design that incorporates three rings of block detectors with an axial coverage of 16.2 cm (Biograph TruePoint PET/CT; Siemens Molecular Imaging). In addition to the phantom measurements, patient Noise Equivalent Count Rates (NECRs) have been estimated for a range of patients with different body weights (42-154 kg). The average spatial resolution is the same for both scanners: 4.4 mm (FWHM) and 5.0 mm (FWHM) at 1 cm and 10 cm respectively from the center of the transverse FOV. The scatter fractions of the Biograph TruePoint and Biograph TruePoint TrueV are comparable at 32%. Compared to the three ring design, the system sensitivity and peak NECR with smoothed randoms correction (1R) increase by 82% and 73%, respectively. The increase in sensitivity from the extended axial coverage of the Biograph TruePoint PET/CT with TrueV should allow a decrease in either scan time or injected dose without compromising diagnostic image quality. The contrast improvement with the PSF reconstruction potentially offers enhanced detectability for small lesions.

  14. Environmental impacts of food consumption by dogs and cats

    PubMed Central

    2017-01-01

    In the US, there are more than 163 million dogs and cats that consume, as a significant portion of their diet, animal products and therefore potentially constitute a considerable dietary footprint. Here, the energy and animal-derived product consumption of these pets in the US is evaluated for the first time, as are the environmental impacts from the animal products fed to them, including feces production. In the US, dogs and cats consume about 19% ± 2% of the amount of dietary energy that humans do (203 ± 15 PJ yr-1 vs. 1051 ± 9 PJ yr-1) and 33% ± 9% of the animal-derived energy (67 ± 17 PJ yr-1 vs. 206 ± 2 PJ yr-1). They produce about 30% ± 13%, by mass, as much feces as Americans (5.1 ± Tg yr-1 vs. 17.2 Tg yr-1), and through their diet, constitute about 25–30% of the environmental impacts from animal production in terms of the use of land, water, fossil fuel, phosphate, and biocides. Dog and cat animal product consumption is responsible for release of up to 64 ± 16 million tons CO2-equivalent methane and nitrous oxide, two powerful greenhouse gasses (GHGs). Americans are the largest pet owners in the world, but the tradition of pet ownership in the US has considerable costs. As pet ownership increases in some developing countries, especially China, and trends continue in pet food toward higher content and quality of meat, globally, pet ownership will compound the environmental impacts of human dietary choices. Reducing the rate of dog and cat ownership, perhaps in favor of other pets that offer similar health and emotional benefits would considerably reduce these impacts. Simultaneous industry-wide efforts to reduce overfeeding, reduce waste, and find alternative sources of protein will also reduce these impacts. PMID:28767700

  15. Environmental impacts of food consumption by dogs and cats.

    PubMed

    Okin, Gregory S

    2017-01-01

    In the US, there are more than 163 million dogs and cats that consume, as a significant portion of their diet, animal products and therefore potentially constitute a considerable dietary footprint. Here, the energy and animal-derived product consumption of these pets in the US is evaluated for the first time, as are the environmental impacts from the animal products fed to them, including feces production. In the US, dogs and cats consume about 19% ± 2% of the amount of dietary energy that humans do (203 ± 15 PJ yr-1 vs. 1051 ± 9 PJ yr-1) and 33% ± 9% of the animal-derived energy (67 ± 17 PJ yr-1 vs. 206 ± 2 PJ yr-1). They produce about 30% ± 13%, by mass, as much feces as Americans (5.1 ± Tg yr-1 vs. 17.2 Tg yr-1), and through their diet, constitute about 25-30% of the environmental impacts from animal production in terms of the use of land, water, fossil fuel, phosphate, and biocides. Dog and cat animal product consumption is responsible for release of up to 64 ± 16 million tons CO2-equivalent methane and nitrous oxide, two powerful greenhouse gasses (GHGs). Americans are the largest pet owners in the world, but the tradition of pet ownership in the US has considerable costs. As pet ownership increases in some developing countries, especially China, and trends continue in pet food toward higher content and quality of meat, globally, pet ownership will compound the environmental impacts of human dietary choices. Reducing the rate of dog and cat ownership, perhaps in favor of other pets that offer similar health and emotional benefits would considerably reduce these impacts. Simultaneous industry-wide efforts to reduce overfeeding, reduce waste, and find alternative sources of protein will also reduce these impacts.

  16. Material and Structural Performance Evaluations of Hwangtoh Admixtures and Recycled PET Fiber-Added Eco-Friendly Concrete for CO₂ Emission Reduction.

    PubMed

    Koo, Bon-Min; Kim, Jang-Ho Jay; Kim, Sung-Bae; Mun, Sungho

    2014-08-19

    In order to reduce carbon dioxide (CO₂) emissions and produce an eco-friendly construction material, a type of concrete that uses a minimal amount of cement, yet still retains equivalent properties to ordinary cement concrete, has been developed and studied all over the world. Hwangtoh, a type of red clay broadly deposited around the world, has traditionally been considered an eco-friendly construction material, with bonus advantages of having health and cost benefits. Presently, Hwangtoh is not commonly used as a modern construction material due to properties such as low strength and high rates of shrinkage cracking. Recent studies, however, have shown that Hwangtoh can be used as a mineral admixture to improve the strength of concrete. In addition, polyethylene terephthalate (PET) fibers recycled from PET bottle waste can be used to control shrinkage cracks in Hwangtoh concrete. Therefore, in this study, performance verification is conducted on newly developed Hwangtoh concrete mixed with short recycled PET fibers. The results show that Hwangtoh concrete has compressive strength, elastic modulus, and pH properties that are similar to these features in ordinary cement concrete. The properties of carbonation depth and creep strain of Hwangtoh concrete, however, are larger and smaller, respectively, than in ordinary cement concrete. According to flexural tests, reinforced concrete (RC) specimens cast with Hwangtoh admixtures (with and without PET fibers) possess similar or better capacities than ordinary RC specimens. The addition of PET fibers significantly improves the structural ductility of RC specimens under normal environmental conditions. However, the implementations of the concrete in aggressive environment must be carefully considered, since a previous study result indicates degradation of its durability performance in aggressive environments, such as seawater [1]. The results of this study validate the possibility of using eco-friendly Hwangtoh concrete reinforced with recycled PET fibers as a structural material for modern construction.

  17. Caracterisation des proprietes dielectriques de materiaux composites a base de polyethylene terephtalate recycle

    NASA Astrophysics Data System (ADS)

    Mebarki, Fouzia

    The aim of this study is to examine the possibility of using thermoplastic composite materials for electrical applications such as supports of automotive engine ignition systems. We are particularly interested in composites based on recycled polyethylene terephtalate (PET). Conventional isolations like PET cannot meet the new prescriptive requirements. The introduction of reinforcement materials, such as glass fibers and mica can improve the mechanical characteristics of these materials. However, this enhancement may also reduce electrical properties especially since these composites have to be used under severe thermal and electric stresses. In order to estimate PET composite insulation lifetimes, accelerated aging tests were carried out at temperatures ranging from room temperature to 140°C and at a frequency of 300Hz. Studies at high temperature will help to identify the service temperature of candidate materials. Dielectric breakdown tests have been made on a large number of samples according to the standard of dielectric strength tests of solid insulating ASTM D-149. These tests have to identify the problematic samples and to check solid insulation quality. The different knowledge gained from this analysis was used to predict material performance. This will give the company the possibility to improve existing formulations and subsequently develop a material having electrical and thermal properties suitable for this application.

  18. Analysis of weld geometry and liquid flow in laser transmission welding between polyethylene terephthalate (PET) and Ti6Al4V based on numerical simulation

    NASA Astrophysics Data System (ADS)

    Ai, Yuewei; Zheng, Kang; Shin, Yung C.; Wu, Benxin

    2018-07-01

    The laser transmission welding of polyethylene terephthalate (PET) and titanium alloy Ti6Al4V involving the evaluating of the resultant geometry and quality of welds is investigated using a fiber laser in this paper. A 3D transient numerical model considering the melting and fluid flow is developed to predict the weld geometry and porosity formation. The temperature field, molten pool and liquid flow are simulated with varying laser power and welding speed based on the model. It is observed that the weld geometry predictions from the numerical simulation are in good agreement with the experimental data. The results show that the porosity consistently appears in the high temperature region due to the decomposition of PET. In addition, it has also been found that the molten pool with a vortex flow pattern is formed only in the PET layer and the welding processing parameters have significant effects on the fluid flow, which eventually affects the heat transfer, molten pool geometry and weld formation. Consequently, it is shown adopting appropriate welding processing parameters based on the proposed model is essential for the sound weld without defects.

  19. Synthesis of carbon nanostructures from high density polyethylene (HDPE) and polyethylene terephthalate (PET) waste by chemical vapour deposition

    NASA Astrophysics Data System (ADS)

    Hatta, M. N. M.; Hashim, M. S.; Hussin, R.; Aida, S.; Kamdi, Z.; Ainuddin, AR; Yunos, MZ

    2017-10-01

    In this study, carbon nanostructures were synthesized from High Density Polyethylene (HDPE) and Polyethylene terephthalate (PET) waste by single-stage chemical vapour deposition (CVD) method. In CVD, iron was used as catalyst and pyrolitic of carbon source was conducted at temperature 700, 800 and 900°C for 30 minutes. Argon gas was used as carrier gas with flow at 90 sccm. The synthesized carbon nanostructures were characterized by FESEM, EDS and calculation of carbon yield (%). FESEM micrograph shows that the carbon nanostructures were only grown as nanofilament when synthesized from PET waste. The synthesization of carbon nanostructure at 700°C was produced smooth and the smallest diameter nanofilament compared to others. The carbon yield of synthesized carbon nanostructures from PET was lower from HDPE. Furthermore, the carbon yield is recorded to increase with increasing of reaction temperature for all samples. Elemental study by EDS analysis were carried out and the formation of carbon nanostructures was confirmed after CVD process. Utilization of polymer waste to produce carbon nanostructures is beneficial to ensure that the carbon nanotechnology will be sustained in future.

  20. Ultraviolet-assisted direct patterning and low-temperature formation of flexible ZrO2 resistive switching arrays on PET/ITO substrates

    NASA Astrophysics Data System (ADS)

    Li, Lingwei; Chen, Yuanqing; Yin, Xiaoru; Song, Yang; Li, Na; Niu, Jinfen; Wu, Huimin; Qu, Wenwen

    2017-12-01

    We demonstrate a low-cost and facile photochemical solution method to prepare the ZrO2 resistive switching arrays as memristive units on flexible PET/ITO substrates. ZrO2 solution sensitive to UV light of 337 nm was synthesized using zirconium n-butyl alcohol as the precursor, and benzoylacetone as the complexing agent. After the dip-coated ZrO2 gel films were irradiated through a mask under the UV lamp (with wavelength of 325-365 nm) at room temperature and rinsed in ethanol, the ZrO2 gel arrays were obtained on PET/ITO substrates. Subsequently, the ZrO2 gel arrays were irradiated by deep UV light of 254 and 185 nm at 150 °C, resulting in the amorphous ZrO2 memristive micro-arrays. The ZrO2 units on flexible PET/ITO substrates exhibited excellent memristive properties. A high ratio of 104 of on-state and off-state resistance was obtained. The resistive switching behavior of the flexible device remained stable after being bent for 103 times. The device showed stable flexibility up to a minimum bending diameter of 1.25 cm.

  1. Development of a MPPC-based prototype gantry for future MRI-PET scanners

    NASA Astrophysics Data System (ADS)

    Kurei, Y.; Kataoka, J.; Kato, T.; Fujita, T.; Ohshima, T.; Taya, T.; Yamamoto, S.

    2014-12-01

    We have developed a high spatial resolution, compact Positron Emission Tomography (PET) module designed for small animals and intended for use in magnetic resonance imaging (MRI) systems. This module consists of large-area, 4 × 4 ch MPPC arrays (S11830-3344MF; Hamamatsu Photonics K.K.) optically coupled with Ce-doped (Lu,Y)2(SiO4)O (Ce:LYSO) scintillators fabricated into 16 × 16 matrices of 0.5 × 0.5 mm2 pixels. We set the temperature sensor (LM73CIMK-0; National Semiconductor Corp.) at the rear of the MPPC acceptance surface, and apply optimum voltage to maintain the gain. The eight MPPC-based PET modules and coincidence circuits were assembled into a gantry arranged in a ring 90 mm in diameter to form the MPPC-based PET system. We have developed two types PET gantry: one made of non-magnetic metal and the other made of acrylonitrile butadiene styrene (ABS) resins. The PET gantry was positioned around the RF coil of the 4.7 T MRI system. We took an image of a point }22Na source under fast spin echo (FSE) and gradient echo (GE), in order to measure the interference between the MPPC-based PET and MRI. The spatial resolution of PET imaging in a transaxial plane of about 1 mm (FWHM) was achieved in all cases. Operating with PET made of ABS has no effect on MR images, while operating with PET made of non-magnetic metal has a significant detrimental effect on MR images. This paper describes our quantitative evaluations of PET images and MR images, and presents a more advanced version of the gantry for future MRI/DOI-PET systems.

  2. Defining optimal tracer activities in pediatric oncologic whole-body 18F-FDG-PET/MRI.

    PubMed

    Gatidis, Sergios; Schmidt, Holger; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schäfer, Jürgen F

    2016-12-01

    To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined 18 F-FDG-PET/MRI in pediatric oncology. 30 18 F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUV mean and SUV max ) as well as SUV variation (SUV var ) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal 18 F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUV mean and SUV max were below 5 % at 18 F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg 18 F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg 18 F-FDG or higher. Administration of 18 F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. Significant reduction in administered 18 F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of 18 F-FDG or other tracers for specific clinical questions have to be further established in selected patient populations.

  3. Application of single- and dual-energy CT brain tissue segmentation to PET monitoring of proton therapy.

    PubMed

    Berndt, Bianca; Landry, Guillaume; Schwarz, Florian; Tessonnier, Thomas; Kamp, Florian; Dedes, George; Thieke, Christian; Würl, Matthias; Kurz, Christopher; Ganswindt, Ute; Verhaegen, Frank; Debus, Jürgen; Belka, Claus; Sommer, Wieland; Reiser, Maximilian; Bauer, Julia; Parodi, Katia

    2017-03-21

    The purpose of this work was to evaluate the ability of single and dual energy computed tomography (SECT, DECT) to estimate tissue composition and density for usage in Monte Carlo (MC) simulations of irradiation induced β + activity distributions. This was done to assess the impact on positron emission tomography (PET) range verification in proton therapy. A DECT-based brain tissue segmentation method was developed for white matter (WM), grey matter (GM) and cerebrospinal fluid (CSF). The elemental composition of reference tissues was assigned to closest CT numbers in DECT space (DECT dist ). The method was also applied to SECT data (SECT dist ). In a validation experiment, the proton irradiation induced PET activity of three brain equivalent solutions (BES) was compared to simulations based on different tissue segmentations. Five patients scanned with a dual source DECT scanner were analyzed to compare the different segmentation methods. A single magnetic resonance (MR) scan was used for comparison with an established segmentation toolkit. Additionally, one patient with SECT and post-treatment PET scans was investigated. For BES, DECT dist and SECT dist reduced differences to the reference simulation by up to 62% when compared to the conventional stoichiometric segmentation (SECT Schneider ). In comparison to MR brain segmentation, Dice similarity coefficients for WM, GM and CSF were 0.61, 0.67 and 0.66 for DECT dist and 0.54, 0.41 and 0.66 for SECT dist . MC simulations of PET treatment verification in patients showed important differences between DECT dist /SECT dist and SECT Schneider for patients with large CSF areas within the treatment field but not in WM and GM. Differences could be misinterpreted as PET derived range shifts of up to 4 mm. DECT dist and SECT dist yielded comparable activity distributions, and comparison of SECT dist to a measured patient PET scan showed improved agreement when compared to SECT Schneider . The agreement between predicted and measured PET activity distributions was improved by employing a brain specific segmentation applicable to both DECT and SECT data.

  4. SU-F-J-222: Using PET Imaging to Evaluate Proliferation and Blood Flow in Irradiated and Non-Irradiated Bone Marrow 1 Year After Chemoradiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGuire, S; Ponto, L; Menda, Y

    Purpose: To compare proliferation and blood flow in pelvic and thoracic bone marrow 1 year after pelvic chemoradiation. Methods: Sixteen pelvic cancer patients were enrolled in an IRB-approved protocol to acquire FLT PET images during radiation therapy simulation (baseline) and 1 year after chemoradiation therapy. Three subjects also had optional O-15 water PET images acquired 1 year after chemoradiation therapy. Baseline FLT PET images were used to create IMRT plans to spare pelvic bone marrow identified as regions with FLT SUV ≥ 2 without compromising PTV coverage or OAR sparing. Marrow VOIs were defined using a 50% maximum pixel valuemore » threshold on baseline FLT PET images (VIEW, PMOD version 3.5) in the sacrum and thoracic spine representing irradiated and non-irradiated regions, respectively. FLT PET and O-15 water PET images acquired 1 year after therapy were co-registered to baseline images (FUSION PMOD) and the same VOIs were used to measure proliferation (FLT SUV) and blood flow (O-15 water uptake). Separate image-based input functions were used for blood flow quantitation in each VOI. Results: Mean 1 year FLT SUV in sacral and thoracic VOIs for were 1.1 ± 0.4 and 6.5 ± 1.7, respectively for N = 16 subjects and were 1.2 ± 0.2 and 5.6 ± 1.6, respectively for N = 3 subjects who also underwent O-15 water imaging. Blood flow measures in equivalent sacral and thoracic marrow regions (N = 3) were 21.3 ± 8.7 and 18.3 ± 4.9 mL/min/100mL respectively. Conclusion: Decreased bone marrow proliferation measured by FLT SUV does not appear to correspond to decreased blood flow as measured by O-15 water PET imaging. Based on this small sample at a single time point, reduced blood supply does not explain reductions in bone marrow proliferative activity 1 year after chemoradiation therapy.« less

  5. A Gain-Programmable Transit-Time-Stable and Temperature-Stable PMT Voltage Divider

    NASA Astrophysics Data System (ADS)

    Liu, Yaqiang; Li, Hongdi; Wang, Yu; Xing, Tao; Xie, Shuping; Uribe, J.; Baghaei, H.; Ramirez, R.; Kim, Soonseok; Wong, Wai-Hoi

    2004-10-01

    A gain-programmable, transit-time-stable, temperature-stable photomultiplier (PMT) voltage divider design is described in this paper. The signal-to-noise ratio can be increased by changing a PMT gain directly instead of adjusting the gain of the preamplifier. PMT gain can be changed only by adjusting the voltages for the dynodes instead of changing the total high voltage between the anode and the photocathode, which can cause a significant signal transit-time variation that cannot be accepted by an application with a critical timing requirement, such as positron emission tomography (PET) or time-of-flight (TOF) detection/PET. The dynode voltage can be controlled by a digital analog converter isolated with a linear optocoupler. The optocoupler consists of an infrared light emission diode (LED) optically coupled with two phototransistors, and one is used in a servo feedback circuit to control the LED drive current for compensating temperature characteristics. The results showed that a six times gain range could be achieved; the gain drift was <0.5% over a 20/spl deg/C temperature range; 250 ps transit-time variation was measured over the entire gain range. A compact print circuit board (PCB) for the voltage divider integrated with a fixed-gain preamplifier has been designed and constructed. It can save about $30 per PMT channel compared with a commercial PMT voltage divider along with a variable gain amplifier. The preamplifier can be totally disabled, therefore in a system with a large amount of PMTs, only one channel can be enabled for calibrating the PMT gain. This new PMT voltage divider design is being applied to our animal PET camera and TOF/PET research.

  6. Simulated responses of terrestrial aridity to black carbon and sulfate aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, L.; Gettelman, A.; Xu, Y.

    Aridity index (AI), defined as the ratio of precipitation to potential evapotranspiration (PET), is a measure of the dryness of terrestrial climate. Global climate models generally project future decreases of AI (drying) associated with global warming scenarios driven by increasing greenhouse gas and declining aerosols. Given their different effects in the climate system, scattering and absorbing aerosols may affect AI differently. In this work, we explore the terrestrial aridity responses to anthropogenic black carbon (BC) and sulfate (SO 4) aerosols with Community Earth System Model simulations. Positive BC radiative forcing decreases precipitation averaged over global land at a rate ofmore » 0.9%/°C of global mean surface temperature increase (moderate drying), while BC radiative forcing increases PET by 1.0%/°C (also drying). BC leads to a global decrease of 1.9%/°C in AI (drying). SO 4 forcing is negative and causes precipitation a decrease at a rate of 6.7%/°C cooling (strong drying). PET also decreases in response to SO 4 aerosol cooling by 6.3%/°C cooling (contributing to moistening). Thus, SO 4 cooling leads to a small decrease in AI (drying) by 0.4%/°C cooling. Despite the opposite effects on global mean temperature, BC and SO 4 both contribute to the twentieth century drying (AI decrease). Sensitivity test indicates that surface temperature and surface available energy changes dominate BC- and SO 4-induced PET changes.« less

  7. Simulated responses of terrestrial aridity to black carbon and sulfate aerosols

    DOE PAGES

    Lin, L.; Gettelman, A.; Xu, Y.; ...

    2016-01-27

    Aridity index (AI), defined as the ratio of precipitation to potential evapotranspiration (PET), is a measure of the dryness of terrestrial climate. Global climate models generally project future decreases of AI (drying) associated with global warming scenarios driven by increasing greenhouse gas and declining aerosols. Given their different effects in the climate system, scattering and absorbing aerosols may affect AI differently. In this work, we explore the terrestrial aridity responses to anthropogenic black carbon (BC) and sulfate (SO 4) aerosols with Community Earth System Model simulations. Positive BC radiative forcing decreases precipitation averaged over global land at a rate ofmore » 0.9%/°C of global mean surface temperature increase (moderate drying), while BC radiative forcing increases PET by 1.0%/°C (also drying). BC leads to a global decrease of 1.9%/°C in AI (drying). SO 4 forcing is negative and causes precipitation a decrease at a rate of 6.7%/°C cooling (strong drying). PET also decreases in response to SO 4 aerosol cooling by 6.3%/°C cooling (contributing to moistening). Thus, SO 4 cooling leads to a small decrease in AI (drying) by 0.4%/°C cooling. Despite the opposite effects on global mean temperature, BC and SO 4 both contribute to the twentieth century drying (AI decrease). Sensitivity test indicates that surface temperature and surface available energy changes dominate BC- and SO 4-induced PET changes.« less

  8. Simulated responses of terrestrial aridity to black carbon and sulfate aerosols: LIN: SIMULATED RESPONSES ARIDITY

    DOE PAGES

    Lin, L.; Gettelman, A.; Xu, Y.; ...

    2016-01-27

    Aridity index (AI), defined as the ratio of precipitation to potential evapotranspiration (PET), is a measure of the dryness of terrestrial climate. Global climate models generally project future decreases of AI (drying) associated with global warming scenarios driven by increasing greenhouse gas and declining aerosols. Given their different effects in the climate system, scattering and absorbing aerosols may affect AI differently. Here we explore the terrestrial aridity responses to anthropogenic black carbon (BC) and sulfate (SO4) aerosols with Community Earth System Model simulations. Positive BC radiative forcing decreases precipitation averaged over global land at a rate of 0.9%/°C of globalmore » mean surface temperature increase (moderate drying), while BC radiative forcing increases PET by 1.0%/°C (also drying). BC leads to a global decrease of 1.9%/°C in AI (drying). SO4 forcing is negative and causes precipitation a decrease at a rate of 6.7%/°C cooling (strong drying). PET also decreases in response to SO4 aerosol cooling by 6.3%/°C cooling (contributing to moistening). Thus, SO4 cooling leads to a small decrease in AI (drying) by 0.4%/°C cooling. Despite the opposite effects on global mean temperature, BC and SO4 both contribute to the twentieth century drying (AI decrease). Sensitivity test indicates that surface temperature and surface available energy changes dominate BC- and SO4-induced PET changes.« less

  9. Physical and clinical performance of the mCT time-of-flight PET/CT scanner.

    PubMed

    Jakoby, B W; Bercier, Y; Conti, M; Casey, M E; Bendriem, B; Townsend, D W

    2011-04-21

    Time-of-flight (TOF) measurement capability promises to improve PET image quality. We characterized the physical and clinical PET performance of the first Biograph mCT TOF PET/CT scanner (Siemens Medical Solutions USA, Inc.) in comparison with its predecessor, the Biograph TruePoint TrueV. In particular, we defined the improvements with TOF. The physical performance was evaluated according to the National Electrical Manufacturers Association (NEMA) NU 2-2007 standard with additional measurements to specifically address the TOF capability. Patient data were analyzed to obtain the clinical performance of the scanner. As expected for the same size crystal detectors, a similar spatial resolution was measured on the mCT as on the TruePoint TrueV. The mCT demonstrated modestly higher sensitivity (increase by 19.7 ± 2.8%) and peak noise equivalent count rate (NECR) (increase by 15.5 ± 5.7%) with similar scatter fractions. The energy, time and spatial resolutions for a varying single count rate of up to 55 Mcps resulted in 11.5 ± 0.2% (FWHM), 527.5 ± 4.9 ps (FWHM) and 4.1 ± 0.0 mm (FWHM), respectively. With the addition of TOF, the mCT also produced substantially higher image contrast recovery and signal-to-noise ratios in a clinically-relevant phantom geometry. The benefits of TOF were clearly demonstrated in representative patient images.

  10. Physical and clinical performance of the mCT time-of-flight PET/CT scanner

    NASA Astrophysics Data System (ADS)

    Jakoby, B. W.; Bercier, Y.; Conti, M.; Casey, M. E.; Bendriem, B.; Townsend, D. W.

    2011-04-01

    Time-of-flight (TOF) measurement capability promises to improve PET image quality. We characterized the physical and clinical PET performance of the first Biograph mCT TOF PET/CT scanner (Siemens Medical Solutions USA, Inc.) in comparison with its predecessor, the Biograph TruePoint TrueV. In particular, we defined the improvements with TOF. The physical performance was evaluated according to the National Electrical Manufacturers Association (NEMA) NU 2-2007 standard with additional measurements to specifically address the TOF capability. Patient data were analyzed to obtain the clinical performance of the scanner. As expected for the same size crystal detectors, a similar spatial resolution was measured on the mCT as on the TruePoint TrueV. The mCT demonstrated modestly higher sensitivity (increase by 19.7 ± 2.8%) and peak noise equivalent count rate (NECR) (increase by 15.5 ± 5.7%) with similar scatter fractions. The energy, time and spatial resolutions for a varying single count rate of up to 55 Mcps resulted in 11.5 ± 0.2% (FWHM), 527.5 ± 4.9 ps (FWHM) and 4.1 ± 0.0 mm (FWHM), respectively. With the addition of TOF, the mCT also produced substantially higher image contrast recovery and signal-to-noise ratios in a clinically-relevant phantom geometry. The benefits of TOF were clearly demonstrated in representative patient images.

  11. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bieniosek, Matthew F.; Lee, Brian J.; Levin, Craig S., E-mail: cslevin@stanford.edu

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom withmore » sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed phantoms can be functionally equivalent to commercially available phantoms. They are a viable option for quickly distributing and fabricating low cost, customized phantoms.« less

  12. EnviroAtlas - Potential Evapotranspiration 1950 - 2099 for the Conterminous United States

    EPA Pesticide Factsheets

    The EnviroAtlas Climate Scenarios were generated from NASA Earth Exchange (NEX) Downscaled Climate Projections (NEX-DCP30) ensemble averages (the average of over 30 available climate models) for each of the four representative concentration pathways (RCP) for the contiguous U.S. at 30 arc-second (approx. 800 m2) spatial resolution. In addition to the three climate variables provided by the NEX-DCP30 dataset (minimum monthly temperature, maximum monthly temperature, and precipitation) a corresponding estimate of potential evapotranspiration (PET) was developed to match the spatial and temporal scales of the input dataset. PET represents the cumulative amount of water returned to the atmosphere due to evaporation from Earth00e2??s surface and plant transpiration under ideal circumstances (i.e., a vegetated surface shading the ground and unlimited water supply). PET was calculated using the Hamon PET equation (Hamon, 1961) and CBM model for daylength (Forsythe et al. 1995) for the 4 RCPs (2.6, 4.5, 6.0, 8.5) and organized by season (Winter, Spring, Summer, and Fall) and annually for the years 2006 00e2?? 2099. Additionally, PET was calculated for the ensemble average of all historic runs and organized similarly for the years 1950 00e2?? 2005. This dataset was produced by the US EPA to support research and online mapping activities related to EnviroAtlas. EnviroAtlas (https://www.epa.gov/enviroatlas) allows the user to interact with a web-based, easy-to-u

  13. Seasonal differences in the subjective assessment of outdoor thermal conditions and the impact of analysis techniques on the obtained results

    NASA Astrophysics Data System (ADS)

    Kántor, Noémi; Kovács, Attila; Takács, Ágnes

    2016-11-01

    Wide research attention has been paid in the last two decades to the thermal comfort conditions of different outdoor and semi-outdoor urban spaces. Field studies were conducted in a wide range of geographical regions in order to investigate the relationship between the thermal sensation of people and thermal comfort indices. Researchers found that the original threshold values of these indices did not describe precisely the actual thermal sensation patterns of subjects, and they reported neutral temperatures that vary among nations and with time of the year. For that reason, thresholds of some objective indices were rescaled and new thermal comfort categories were defined. This research investigates the outdoor thermal perception patterns of Hungarians regarding the Physiologically Equivalent Temperature ( PET) index, based on more than 5800 questionnaires. The surveys were conducted in the city of Szeged on 78 days in spring, summer, and autumn. Various, frequently applied analysis approaches (simple descriptive technique, regression analysis, and probit models) were adopted to reveal seasonal differences in the thermal assessment of people. Thermal sensitivity and neutral temperatures were found to be significantly different, especially between summer and the two transient seasons. Challenges of international comparison are also emphasized, since the results prove that neutral temperatures obtained through different analysis techniques may be considerably different. The outcomes of this study underline the importance of the development of standard measurement and analysis methodologies in order to make future studies comprehensible, hereby facilitating the broadening of the common scientific knowledge about outdoor thermal comfort.

  14. Sustainable carbothermal reduction and nitridation of Malaysian ilmenite by polyethylene terephthalate and coal

    NASA Astrophysics Data System (ADS)

    Ahmadi, Eltefat; Hamid, Sheikh Abdul Rezan Sheikh Abdul; Hussin, Hashim; Baharun, Norlia; Ariffin, Kamar Shah; Ramakrishnan, Sivakumar; Fauzi, M. N. Ahmad; Ismail, Hanafi

    2017-07-01

    In this paper, the carbothermal reduction and nitridation (CTRN) of Malaysian ilmenite has been studied as a part of crucial steps involved in reduction and subsequent chlorination processes for synthesizing titanium tetrachloride (TiCl4) from nitrided Malaysian ilmenite concentrates. In CTRN, waste plastics such as polyethylene terephthalate (PET) could be utilized as an alternative source of carbon reductant. In this study, titanium oxycarbonitride (TiOxCyNz) separated from iron (Fe) phase was synthesized by non-isothermal CTRN of Malaysian ilmenite under H2-N2 atmosphere by utilizing a mixture of Sarawak Mukah-Balingan coal and PET as reducing agents in a horizontal tube furnace. Experiments have been carried out in the temperature range of 1150-1250°C for 3 hours with various ratios of PET to coal (25 wt.% PET, 50 wt.% PET, and 75 wt.% PET). X-ray diffraction (XRD), X-ray fluorescence (XRF), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) methods of analysis were conducted to assess the microstructures and chemical compositions of the unreduced and reduced samples. The results indicated that utilizing PET had a significant effect on iron separation from titanium oxycarbonitride (TiO0.02C0.13N0.85) at 1250°C with a mixture of 75 wt.% PET. Furthermore, XRD and SEM studies demonstrated that with increasing PET weight ratio in the mixtures, the rate of conversion increased and a low-carbon TiOxCyNz with minimal intermediate titanium sub-oxides was synthesized. The method of applying PET as potential reductant for CTRN of ilmenite has beneficial side effects in sustainable recycling of waste PET.

  15. Hybrid radio-frequency/direct-current plasma-enhanced chemical vapor deposition system for deposition on inner surfaces of polyethylene terephthalate bottles

    NASA Astrophysics Data System (ADS)

    Li, Jing; Tian, Xiubo; Gong, Chunzhi; Yang, Shiqin; Fu, Ricky K. Y.; Chu, Paul K.

    2009-12-01

    A hybrid radio-frequency (rf)/direct-current (dc) system has been developed to control the biasing effects during deposition of diamondlike carbon (DLC) films onto the inner wall of polyethylene terephthalate (PET) bottles. An additional dc bias is coupled to the rf electrode to produce the effect of equivalent rf self-biasing. This allows more flexible control of the deposition of the DLC films which are intended to improve the gas barrier characteristics. The experimental results demonstrate that the additional dc bias improves the adhesion strength between the DLC film and PET, although the enhancement in the gas barrier properties is not significantly larger compared to the one without dc bias. The apparatus and methodology have practical importance in the food and beverage industry.

  16. Optimization of PET instrumentation for brain activation studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dahlbom, M.; Cherry, S.R.; Hoffman, E.J.

    By performing cerebral blood flow studies with positron emission tomography (PET), and comparing blood flow images of different states of activation, functional mapping of the brain is possible. The ability of current commercial instruments to perform such studies is investigated in this work, based on a comparison of noise equivalent count (NEC) rates. Differences in the NEC performance of the different scanners in conjunction with scanner design parameters, provide insights into the importance of block design (size, dead time, crystal thickness) and overall scanner design (sensitivity and scatter fraction) for optimizing data from activation studies. The newer scanners with removablemore » septa, operating with 3-D acquisition, have much higher sensitivity, but require new methodology for optimized operation. Only by administering multiple low doses (fractionation) of the flow tracer can the high sensitivity be utilized.« less

  17. Recyclability of PET/WPI/PE Multilayer Films by Removal of Whey Protein Isolate-Based Coatings with Enzymatic Detergents

    PubMed Central

    Cinelli, Patrizia; Schmid, Markus; Bugnicourt, Elodie; Coltelli, Maria Beatrice; Lazzeri, Andrea

    2016-01-01

    Multilayer plastic films provide a range of properties, which cannot be obtained from monolayer films but, at present, their recyclability is an open issue and should be improved. Research to date has shown the possibility of using whey protein as a layer material with the property of acting as an excellent barrier against oxygen and moisture, replacing petrochemical non-recyclable materials. The innovative approach of the present research was to achieve the recyclability of the substrate films by separating them, with a simple process compatible with industrial procedures, in order to promote recycling processes leading to obtain high value products that will beneficially impact the packaging and food industries. Hence, polyethyleneterephthalate (PET)/polyethylene (PE) multi-layer film was prepared based on PET coated with a whey protein layer, and then the previous structure was laminated with PE. Whey proteins, constituting the coating, can be degraded by enzymes so that the coating films can be washed off from the plastic substrate layer. Enzyme types, dosage, time, and temperature optima, which are compatible with procedures adopted in industrial waste recycling, were determined for a highly-efficient process. The washing of samples based on PET/whey and PET/whey/PE were efficient when performed with enzymatic detergent containing protease enzymes, as an alternative to conventional detergents used in recycling facilities. Different types of enzymatic detergents tested presented positive results in removing the protein layer from the PET substrate and from the PET/whey/PE multilayer films at room temperature. These results attested to the possibility of organizing the pre-treatment of the whey-based multilayer film by washing with different available commercial enzymatic detergents in order to separate PET and PE, thus allowing a better recycling of the two different polymers. Mechanical properties of the plastic substrate, such as stress at yield, stress and elongation at break, evaluated by tensile testing on films before and after cleaning, were are not significantly affected by washing with enzymatic detergents. PMID:28773592

  18. Alternate corrections for estimating actual wetland evapotranspiration from potential evapotranspiration

    USGS Publications Warehouse

    Shoemaker, W. Barclay; Sumner, D.M.

    2006-01-01

    Corrections can be used to estimate actual wetland evapotranspiration (AET) from potential evapotranspiration (PET) as a means to define the hydrology of wetland areas. Many alternate parameterizations for correction coefficients for three PET equations are presented, covering a wide range of possible data-availability scenarios. At nine sites in the wetland Everglades of south Florida, USA, the relatively complex PET Penman equation was corrected to daily total AET with smaller standard errors than the PET simple and Priestley-Taylor equations. The simpler equations, however, required less data (and thus less funding for instrumentation), with the possibility of being corrected to AET with slightly larger, comparable, or even smaller standard errors. Air temperature generally corrected PET simple most effectively to wetland AET, while wetland stage and humidity generally corrected PET Priestley-Taylor and Penman most effectively to wetland AET. Stage was identified for PET Priestley-Taylor and Penman as the data type with the most correction ability at sites that are dry part of each year or dry part of some years. Finally, although surface water generally was readily available at each monitoring site, AET was not occurring at potential rates, as conceptually expected under well-watered conditions. Apparently, factors other than water availability, such as atmospheric and stomata resistances to vapor transport, also were limiting the PET rate. ?? 2006, The Society of Wetland Scientists.

  19. Materials characterization and histological analysis of explanted polypropylene, PTFE, and PET hernia meshes from an individual patient

    PubMed Central

    Wood, A. J.; Cozad, M. J.; Grant, D. A.; Ostdiek, A. M.; Bachman, S. L.

    2014-01-01

    During its tenure in vivo, synthetic mesh materials are exposed to foreign body responses, which can alter physicochemical properties of the material. Three different synthetic meshes comprised of polypropylene, expanded polytetrafluoroethylene (ePTFE), and polyethylene terephthalate (PET) materials were explanted from a single patient providing an opportunity to compare physicochemical changes between three different mesh materials in the same host. Results from infrared spectroscopy demonstrated significant oxidation in polypropylene mesh while ePTFE and PET showed slight chemical changes that may be caused by adherent scar tissue. Differential scanning calorimetry results showed a significant decrease in the heat of enthalpy and melt temperature in the polypropylene mesh while the ePTFE and PET showed little change. The presence of giant cells and plasma cells surrounding the ePTFE and PET were indicative of an active foreign body response. Scanning electron micrographs and photo micrographs displayed tissue entrapment and distortion of all three mesh materials. PMID:23371769

  20. PET Radiotracers for Imaging the Proliferation Status of Breast Tumors

    DTIC Science & Technology

    2004-12-01

    390 627 ±244 12,900±111 8.2± 1.415 58.8± 13.7 2.1 ±0.4 809±66 75.0±4.1 75-85% yield. Reduction with either lithium aluminum 16 107.0± 19.0 10.2±5.3 751... hexafluorophosphate (BOP) or 1,3- dicyclohexylcarbodiimide (DCC) and 2.5 equivalents of triethylamine were added, and the solution was allowed to warm

  1. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    NASA Astrophysics Data System (ADS)

    Bowen, S. R.; Nyflot, M. J.; Herrmann, C.; Groh, C. M.; Meyer, J.; Wollenweber, S. D.; Stearns, C. W.; Kinahan, P. E.; Sandison, G. A.

    2015-05-01

    Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [18F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.

  2. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study.

    PubMed

    Bowen, S R; Nyflot, M J; Herrmann, C; Groh, C M; Meyer, J; Wollenweber, S D; Stearns, C W; Kinahan, P E; Sandison, G A

    2015-05-07

    Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [(18)F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.

  3. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    PubMed Central

    Bowen, S R; Nyflot, M J; Hermann, C; Groh, C; Meyer, J; Wollenweber, S D; Stearns, C W; Kinahan, P E; Sandison, G A

    2015-01-01

    Effective positron emission tomography/computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [18F]FDG. The lung lesion insert was driven by 6 different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy (VMAT) were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses (EUD), and 2%-2mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10–20%, treatment planning errors were 5–10%, and treatment delivery errors were 5–30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5–10% in PET/CT imaging, < 5% in treatment planning, and < 2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery. PMID:25884892

  4. Motion and Emotional Behavior Design for Pet Robot Dog

    NASA Astrophysics Data System (ADS)

    Cheng, Chi-Tai; Yang, Yu-Ting; Miao, Shih-Heng; Wong, Ching-Chang

    A pet robot dog with two ears, one mouth, one facial expression plane, and one vision system is designed and implemented so that it can do some emotional behaviors. Three processors (Inter® Pentium® M 1.0 GHz, an 8-bit processer 8051, and embedded soft-core processer NIOS) are used to control the robot. One camera, one power detector, four touch sensors, and one temperature detector are used to obtain the information of the environment. The designed robot with 20 DOF (degrees of freedom) is able to accomplish the walking motion. A behavior system is built on the implemented pet robot so that it is able to choose a suitable behavior for different environmental situation. From the practical test, we can see that the implemented pet robot dog can do some emotional interaction with the human.

  5. Sport events and climate for visitors—the case of FIFA World Cup in Qatar 2022

    NASA Astrophysics Data System (ADS)

    Matzarakis, Andreas; Fröhlich, Dominik

    2015-04-01

    The effect of weather on sport events is not well studied. It requires special attention if the event is taking place at a time and place with extreme weather situations. For the world soccer championship in Qatar (Doha 2022), human biometeorological analysis has been performed in order to identify the time of the year that is most suitable in terms of thermal comfort for visitors attending the event. The analysis is based on thermal indices like Physiologically Equivalent Temperature (PET). The results show that this kind of event may be not appropriate for visitors, if it is placed during months with extreme conditions. For Doha, this is the period from May to September, when conditions during a large majority of hours of the day cause strong heat stress for the visitors. A more appropriate time would be the months November to February, when thermally comfortable conditions are much more frequent. The methods applied here can quantify the thermal conditions and show limitations and possibilities for specific events and locations.

  6. Comparison of [(18)F]altanserin and [(18)F]deuteroaltanserin for PET imaging of serotonin(2A) receptors in baboon brain: pharmacological studies.

    PubMed

    Staley, J K; Van Dyck, C H; Tan, P Z; Al Tikriti, M; Ramsby, Q; Klump, H; Ng, C; Garg, P; Soufer, R; Baldwin, R M; Innis, R B

    2001-04-01

    The regional distribution in brain, distribution volumes, and pharmacological specificity of the PET 5-HT(2A) receptor radiotracer [(18)F]deuteroaltanserin were evaluated and compared to those of its non-deuterated derivative [(18)F]altanserin. Both radiotracers were administered to baboons by bolus plus constant infusion and PET images were acquired up to 8 h. The time-activity curves for both tracers stabilized between 4 and 6 h. The ratio of total and free parent to metabolites was not significantly different between radiotracers; nevertheless, total cortical R(T) (equilibrium ratio of specific to nondisplaceable brain uptake) was significantly higher (34-78%) for [(18)F]deuteroaltanserin than for [(18)F]altanserin. In contrast, the binding potential (Bmax/K(D)) was similar between radiotracers. [(18)F]Deuteroaltanserin cortical activity was displaced by the 5-HT(2A) receptor antagonist SR 46349B but was not altered by changes in endogenous 5-HT induced by fenfluramine. These findings suggest that [(18)F]deuteroaltanserin is essentially equivalent to [(18)F]altanserin for 5-HT(2A) receptor imaging in the baboon.

  7. Performance of the Tachyon Time-of-Flight PET Camera

    NASA Astrophysics Data System (ADS)

    Peng, Q.; Choong, W.-S.; Vu, C.; Huber, J. S.; Janecek, M.; Wilson, D.; Huesman, R. H.; Qi, Jinyi; Zhou, Jian; Moses, W. W.

    2015-02-01

    We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm2 side of 6.15 ×6.15 ×25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.

  8. Performance of the Tachyon Time-of-Flight PET Camera.

    PubMed

    Peng, Q; Choong, W-S; Vu, C; Huber, J S; Janecek, M; Wilson, D; Huesman, R H; Qi, Jinyi; Zhou, Jian; Moses, W W

    2015-02-01

    We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 × 25 mm 2 side of 6.15 × 6.15 × 25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.

  9. Performance of the Tachyon Time-of-Flight PET Camera

    PubMed Central

    Peng, Q.; Choong, W.-S.; Vu, C.; Huber, J. S.; Janecek, M.; Wilson, D.; Huesman, R. H.; Qi, Jinyi; Zhou, Jian; Moses, W. W.

    2015-01-01

    We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon’s detector module is optimized for timing by coupling the 6.15 × 25 mm2 side of 6.15 × 6.15 × 25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/− ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3. PMID:26594057

  10. Performance of the Tachyon Time-of-Flight PET Camera

    DOE PAGES

    Peng, Q.; Choong, W. -S.; Vu, C.; ...

    2015-01-23

    We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm 2 side of 6.15 ×6.15 ×25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according tomore » the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.« less

  11. Thermal Inactivation of Feline Calicivirus in Pet Food Processing.

    PubMed

    Haines, J; Patel, M; Knight, A I; Corley, D; Gibson, G; Schaaf, J; Moulin, J; Zuber, S

    2015-12-01

    Extrusion is the most common manufacturing process used to produce heat-treated dry dog and cat food (pet food) for domestic use and international trade. Due to reoccurring outbreaks of notifiable terrestrial animal diseases and their impact on international trade, experiments were undertaken to demonstrate the effectiveness of heat-treated extruded pet food on virus inactivation. The impact of extrusion processing in a pet food matrix on virus inactivation has not been previously reported and very few inactivation studies have examined the thermal inactivation of viruses in complex food matrices. The feline calicivirus vaccine strain FCV F-9 was used as a surrogate model RNA virus pathogen. Small-scale heat inactivation experiments using animal-derived pet food raw materials showed that a > 4 log10 reduction (log10 R) in infectivity occurred at 70 °C prior to reaching the minimum extrusion manufacturing operating temperature of 100 °C. As anticipated, small-scale pressure studies at extrusion pressure (1.6 MPa) showed no apparent effect on FCV F-9 inactivation. Additionally, FCV F-9 was shown not to survive the acidic conditions used to produce pet food palatants of animal origin that are typically used as a coating after the extrusion process.

  12. Solubilization and Upgrading of High Polyethylene Terephthalate Loadings in a Low-Costing Bifunctional Ionic Liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Jian; Liu, Dajiang; Young, Robert P.

    Polyethylene terephthalate (PET) is of significant commercial importance, but is difficult to recycle. Chemical inertness and resistance to biodegradation make the recycling of PET challenging and most solvents for PET are highly toxic. In this work, we demonstrate for the first time that a low cost (~$1.2/kg) and biocompatible ionic liquid (IL), cholinium phosphate ([Ch]3[PO4]) can play bifunctional roles in PET solubilization and glycolytic degradation. High loading of PET (10 wt%) is readily dissolved in [Ch]3[PO4] at relatively low temperatures (120 °C, 1h) and even in water-rich conditions. Tandem in situ confocal microscopy and Fourier Transform Infrared (FTIR) spectroscopy studiesmore » give detailed information on the solubilization mechanism in terms of morphological and chemical changes that occur. In depth analysis of PET-IL solution reveals that the high PET solubilization in [Ch]3[PO4] can be ascribed to significant PET depolymerization. Acid precipitation yields terephthalic acid as the dominant depolymerized monomer with a theoretical yield of ~95%. Further exploration shows that in the presence of ethylene glycol, [Ch]3[PO4] catalyzed glycolysis of PET can efficiently occur with ~100% PET conversion and ~60.6% bis(2-hydroxyethyl)terephthalate (BHET) yield under metal free conditions. The IL can be reused at least three times without an apparent decrease in activity. NMR analysis reveals that strong hydrogen bond interactions between EG and the IL play an important role for EG activation and promotion of the glycolysis reaction. This study opens up avenues for exploring environmentally benign and efficient technology of ILs for solubilizing and recycling postconsumer polyester plastics.« less

  13. Effect of Patient Set-up and Respiration motion on Defining Biological Targets for Image-Guided Targeted Radiotherapy

    NASA Astrophysics Data System (ADS)

    McCall, Keisha C.

    Identification and monitoring of sub-tumor targets will be a critical step for optimal design and evaluation of cancer therapies in general and biologically targeted radiotherapy (dose-painting) in particular. Quantitative PET imaging may be an important tool for these applications. Currently radiotherapy planning accounts for tumor motion by applying geometric margins. These margins create a motion envelope to encompass the most probable positions of the tumor, while also maintaining the appropriate tumor control and normal tissue complication probabilities. This motion envelope is effective for uniform dose prescriptions where the therapeutic dose is conformed to the external margins of the tumor. However, much research is needed to establish the equivalent margins for non-uniform fields, where multiple biological targets are present and each target is prescribed its own dose level. Additionally, the size of the biological targets and close proximity make it impractical to apply planning margins on the sub-tumor level. Also, the extent of high dose regions must be limited to avoid excessive dose to the surrounding tissue. As such, this research project is an investigation of the uncertainty within quantitative PET images of moving and displaced dose-painting targets, and an investigation of the residual errors that remain after motion management. This included characterization of the changes in PET voxel-values as objects are moved relative to the discrete sampling interval of PET imaging systems (SPECIFIC AIM 1). Additionally, the repeatability of PET distributions and the delineating dose-painting targets were measured (SPECIFIC AIM 2). The effect of imaging uncertainty on the dose distributions designed using these images (SPECIFIC AIM 3) has also been investigated. This project also included analysis of methods to minimize motion during PET imaging and reduce the dosimetric impact of motion/position-induced imaging uncertainty (SPECIFIC AIM 4).

  14. SU-E-J-122: Detecting Treatment-Induced Metabolic Abnormalities in Craniopharyngioma Patients Undergoing Surgery and Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, C; Shulkin, B; Li, Y

    Purpose: To identify treatment-induced defects in the brain of children with craniopharyngioma receiving surgery and proton therapy using fluorodeoxyglucose positron emission tomography (FDG PET). Methods: Forty seven patients were enrolled on a clinical trial for craniopharyngioma with serial imaging and functional evaluations. Proton therapy was delivered using the double-scattered beams with a prescribed dose of 54 Cobalt Gray Equivalent. FDG tracer uptake in each of 63 anatomical regions was computed after warping PET images to a 3D reference template in Talairach coordinates. Regional uptake was deemed significantly low or high if exceeding two standard deviations of normal population from themore » mean. For establishing the normal ranges, 132 children aged 1–20 years with noncentral nervous system related diseases and normal-appearing cerebral PET scans were analyzed. Age- and gender-dependent regional uptake models were developed by linear regression and confidence intervals were calculated. Results: Most common PET abnormality before proton therapy was significantly low uptake in the frontal lobe, the occipital lobe (particularly in cuneus), the medial and ventral temporal lobe, cingulate gyrus, caudate nuclei, and thalamus. They were related to injury from surgical corridors, tumor mass effect, insertion of a ventricular catheter, and the placement of an Ommaya reservoir. Surprisingly a significantly high uptake was observed in temporal gyri and the parietal lobe. In 13 patients who already completed 18-month PET scans, metabolic abnormalities improved in 11 patients from baseline. One patient had persistent abnormalities. Only one revealed new uptake abnormalities in thalamus, brainstem, cerebellum, and insula. Conclusion: Postoperative FDG PET of craniopharyngioma patients revealed metabolic abnormalities in specific regions of the brain. Proton therapy did not appear to exacerbate these surgery- and tumor-induced defects. In patients with persistent and new abnormalities, continued investigation on clinical symptoms and cognitive outcomes is ongoing to establish the association and predictive values of metabolic imaging.« less

  15. Long-term change of potential evapotranspiration over Southwest China and teleconnections with large-scale climate anomalies

    NASA Astrophysics Data System (ADS)

    Liu, B.; Chen, X.; Li, Y.; Chen, Z.

    2017-12-01

    bstract: Potential evapotranspiration (PET) is a sensitive factor for atmospheric and ecological systems over Southwest China which is characterized by intensive karst geomorphology and fragile environment. Based on daily meteorological data of 94 stations during 1961-2013, the spatiotemporal characteristics of PET are analyzed. The changing characteristics of local meteorological factors and large-scale climatic features are also investigated to explain the potential reasons for changing PET. Study results are as follows: (1) The high-value center of PET with a mean value of 1097 mm/a locates in the south mainly resulted from the regional climatic features of higher air temperature (TEM), sunshine duration (SSD) and lower relative humidity (RHU); and the low-value center of PET with a mean value of 831 mm/a is in the northeast primarily attributed to higher RHU and weaker SSD. (2) Annual PET decreases at -10.04 mm decade-1 before the year 2000 but increases at 50.65 mm decade-1 thereafter; and the dominant factors of PET change are SSD, RHU and wind speed (WIN), with the relative contributions of 33.29%, 25.42% and 22.16%, respectively. (3) The abrupt change of PET in 2000 is strongly dominated by large-scale climatic anomalies. The strengthened 850hPa geostrophic wind (0.51 ms-1 decade-1), weakened total cloud cover (-2.25 % decade-1) and 500hPa water vapor flux (-2.85 % decade-1) have provided advantageous dynamic, thermal and dry conditions for PET over Southwest China since the 21st century.

  16. Shift in potential evapotranspiration and its implications for dryness/wetness over Southwest China

    NASA Astrophysics Data System (ADS)

    Sun, Shanlei; Chen, Haishan; Wang, Guojie; Li, Jinjian; Mu, Mengyuan; Yan, Guixia; Xu, Bei; Huang, Jin; Wang, Jie; Zhang, Fangmin; Zhu, Siguang

    2016-08-01

    During 1961-2012, the regional average annual potential evapotranspiration (PET) of Southwest China (SWC) and the four subregions (named as SR1, SR2, SR3, and SR4) showed different decreases (excluding SR3); while the breakpoint analysis suggested that PET changes (i.e., sign and magnitude) have shifted. Based on a group of sensitivity experiments with Penman-Monteith equation and a new separating method, the contributions of each climate factor alone (i.e., net radiation, Rn; mean temperature, Tave; wind speed, Wnd; and vapor pressure deficit, Vpd) to PET changes were calculated. Results showed that declined Wnd in SR1, reduced Rn in SR2, SR4, and SWC, and increased Vpd in SR3 were responsible for the PET changes during 1961-2012. However, the determinant factor for each subregion and SWC varied in different segmented periods, which were identified using the breakpoint analysis. The impacts of PET shifts on SWC dryness/wetness (reflected by the 3 month Standardized Precipitation-Evapotranspiration index, SPEI-3) during 1961-2012 were then quantified. Briefly, SPEI-3 changes in SR3, SR4, and SWC had the determinant factor of PET in the first one or two period(s), and precipitation in the last period; while they were attributed to PET (precipitation) in SR1 (SR2) for each segmented period. It is found that PET and precipitation had comparable contributions to the variations in SWC dryness/wetness. Our findings have suggested that more attentions should be paid to the impacts of PET changes and shifts in future studies of dryness/wetness or drought.

  17. Improved LabPET Detectors Using Lu1.8Gd0.2SiO5:Ce (LGSO) Scintillator Blocks

    NASA Astrophysics Data System (ADS)

    Bergeron, Mélanie; Pepin, Catherine M.; Cadorette, Jules; Loignon-Houle, Francis; Fontaine, Réjean; Lecomte, Roger

    2015-02-01

    The scintillator is one of the key building blocks that critically determine the physical performance of PET detectors. The quest for scintillation crystals with improved characteristics has been crucial in designing scanners with superior imaging performance. Recently, it was shown that the decay time constant of high lutetium content Lu1.8Gd0.2SiO5: Ce (LGSO) scintillators can be adjusted by varying the cerium concentration from 0.025 mol% to 0.75 mol%, thus providing interesting characteristics for phoswich detectors. The high light output (90%-120% NaI) and the improved spectral match of these scintillators with avalanche photodiode (APD) readout promise superior energy and timing resolutions. Moreover, their improved mechanical properties, as compared to conventional LGSO ( Lu0.4Gd1.6SiO5: Ce), make block array manufacturing readily feasible. To verify these assumptions, new phoswich block arrays made of LGSO-90%Lu with low and high mol% Ce concentrations were fabricated and assembled into modules dedicated to the LabPET scanner. Typical crystal decay time constants were 31 ns and 47 ns, respectively. Phoswich crystal identification performed using a digital pulse shape discrimination algorithm yielded an average 8% error. At 511 keV, an energy resolution of 17-21% was obtained, while coincidence timing resolution between 4.6 ns and 5.2 ns was achieved. The characteristics of this new LGSO-based phoswich detector module are expected to improve the LabPET scanner performance. The higher stopping power would increase the detection efficiency. The better timing resolution would also allow the use of a narrower coincidence window, thus minimizing the random event rate. Altogether, these two improvements will significantly enhance the noise equivalent count rate performance of an all LGSO-based LabPET scanner.

  18. Cost analysis of PET and comprehensive lifestyle modification for the reversal of atherosclerosis.

    PubMed

    Delgado, Rigoberto I; Swint, J Michael; Lairson, David R; Johnson, Nils P; Gould, K Lance; Sdringola, Stefano

    2014-01-01

    We present a preliminary cost analysis of a combination intervention using PET and comprehensive lifestyle modification to reverse atherosclerosis. With a sensitivity of 92%-95% and specificity of 85%-95%, PET is an essential tool for high-precision diagnosis of coronary artery disease, accurately guiding optimal treatment for both symptomatic and asymptomatic patients. PET imaging provides a powerful visual and educational aid for helping patients identify and adopt appropriate treatments. However, little is known about the operational cost of using the technology for this purpose. The analysis was done in the context of the Century Health Study for Cardiovascular Medicine (Century Trial), a 1,300-patient, randomized study combining PET imaging with lifestyle changes. Our methodology included a microcosting and time study focusing on estimating average direct and indirect costs. The total cost of the Century Trial in present-value terms is $9.2 million, which is equal to $7,058 per patient. Sensitivity analysis indicates that the present value of total costs is likely to range between $8.8 and $9.7 million, which is equivalent to $6,655-$7,606 per patient. The clinical relevance of the Century Trial is significant since it is, to our knowledge, the first randomized controlled trial to combine high-precision imaging with lifestyle strategies. The Century Trial is in its second year of a 5-y protocol, and we present preliminary findings. The results of this cost study, however, provide policy makers with an early estimate of the costs of implementing, at large scale, a combined intervention such as the Century Trial. Further, we believe that imaging-guided lifestyle management may have considerable potential for improving outcomes and reducing health-care costs by eliminating unnecessary invasive procedures.

  19. Assessment of a fully 3D Monte Carlo reconstruction method for preclinical PET with iodine-124

    NASA Astrophysics Data System (ADS)

    Moreau, M.; Buvat, I.; Ammour, L.; Chouin, N.; Kraeber-Bodéré, F.; Chérel, M.; Carlier, T.

    2015-03-01

    Iodine-124 is a radionuclide well suited to the labeling of intact monoclonal antibodies. Yet, accurate quantification in preclinical imaging with I-124 is challenging due to the large positron range and a complex decay scheme including high-energy gammas. The aim of this work was to assess the quantitative performance of a fully 3D Monte Carlo (MC) reconstruction for preclinical I-124 PET. The high-resolution small animal PET Inveon (Siemens) was simulated using GATE 6.1. Three system matrices (SM) of different complexity were calculated in addition to a Siddon-based ray tracing approach for comparison purpose. Each system matrix accounted for a more or less complete description of the physics processes both in the scanned object and in the PET scanner. One homogeneous water phantom and three heterogeneous phantoms including water, lungs and bones were simulated, where hot and cold regions were used to assess activity recovery as well as the trade-off between contrast recovery and noise in different regions. The benefit of accounting for scatter, attenuation, positron range and spurious coincidences occurring in the object when calculating the system matrix used to reconstruct I-124 PET images was highlighted. We found that the use of an MC SM including a thorough modelling of the detector response and physical effects in a uniform water-equivalent phantom was efficient to get reasonable quantitative accuracy in homogeneous and heterogeneous phantoms. Modelling the phantom heterogeneities in the SM did not necessarily yield the most accurate estimate of the activity distribution, due to the high variance affecting many SM elements in the most sophisticated SM.

  20. A 400-ka tephrochronological framework for Central America from Lake Petén Itzá (Guatemala) sediments

    NASA Astrophysics Data System (ADS)

    Kutterolf, S.; Schindlbeck, J. C.; Anselmetti, F. S.; Ariztegui, D.; Brenner, M.; Curtis, J.; Schmid, D.; Hodell, D. A.; Mueller, A.; Pérez, L.; Pérez, W.; Schwalb, A.; Frische, M.; Wang, K.-L.

    2016-10-01

    Lake Petén Itzá, northern Guatemala, lies within a hydrologically closed basin in the south-central area of the Yucatán Peninsula, and was drilled under the auspices of the International Continental Scientific Drilling Program (ICDP) in 2006. At 16°55‧N latitude, the lake is ideally located for study of past climate and environmental conditions in the Neotropical lowlands. Because of its great depth (>160 m), Lake Petén Itzá has a record of continuous sediment accumulation that extends well into the late Pleistocene. A key obstacle to obtaining long climate records from the region is the difficulty of establishing a robust chronology beyond ∼40 ka, the limit of 14C dating. Tephra layers within the Lake Petén Itzá sediments, however, enable development of age/depth relations beyond 40 ka. Ash beds from large-magnitude, Pleistocene-to-Holocene silicic eruptions of caldera volcanoes along the Central American Volcanic Arc (CAVA) were found throughout drill cores collected from Lake Petén Itzá. These ash beds were used to establish a robust chronology extending back 400 ka. We used major- and trace-element glass composition to establish 12 well-constrained correlations between the lacustrine tephra layers in Lake Petén Itzá sediments and dated deposits at the CAVA source volcanoes, and with their marine equivalents in eastern Pacific Ocean sediments. The data also enabled revision of eight previous determinations of erupted volumes and masses, and initial estimates for another four eruptions, as well as the designation of source areas for 14 previously unknown eruptions. The new and revised sedimentation rates for the older sediment successions identify the interglacial of MIS5a between 84 and 72 ka, followed by a stadial between 72 and 59 ka that corresponds to MIS4. We modified the age models for the Lake Petén Itzá sediment sequences, extended the paleoclimate and paleoecological record for this Neotropical region to ∼400 ka, and determined the magnitude and timing of CAVA eruptions.

  1. Molybdenum Hydride and Dihydride Complexes Bearing Diphosphine Ligands with a Pendant Amine: Formation of Complexes With Bound Amines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Shaoguang; Bullock, R. Morris

    2015-07-06

    CpMo(CO)(PNP)H complexes (PNP = (R2PCH2)2NMe, R = Et or Ph) were synthesized by displacement of two CO ligands of CpMo(CO)3H by the PNP ligand; these complexes were characterized by IR and variable temperature 1H and 31P NMR spectroscopy. CpMo(CO)(PNP)H complexes are formed as mixture of cis and trans-isomers. Both cis-CpMo(CO)(PEtNMePEt)H and trans-CpMo(CO)(PPhNMePPh)H were analyzed by single crystal X-ray diffraction. Electrochemical oxidation of CpMo(CO)(PEtNMePEt)H and CpMo(CO)(PPhNMePPh)H in CH3CN are both irreversible at slow scan rates and quasi-reversible at higher scan rates, with E1/2 = -0.36 V (vs. Cp2Fe+/0) for CpMo(CO)(PEtNMePEt)H and E1/2 = -0.18 V for CpMo(CO)(PPhNMePPh)H. Hydride abstraction from CpMo(CO)(PNP)Hmore » with [Ph3C]+[A]- (A = B(C6F5)4 or BArF4; [ArF = 3,5-bis(trifluoromethyl)phenyl]) afforded “tuck-in” [CpMo(CO)(κ3-PNP)]+ complexes that feature the amine bound to the metal. Displacement of the κ3 Mo-N bond by CD3CN gives [CpMo(CO)(PNP)(CD3CN)]+. The kinetics of this reaction were studied by NMR spectroscopy, providing the activation parameters ΔH‡ = 22.1 kcal/mol, ΔS‡ = 1.89 cal/(mol·K), Ea = 22.7 kcal/mol. Protonation of CpMo(CO)(PEtNMePEt)H affords [CpMo(CO)(κ2-PEtNMePEt)(H)2]+ as a Mo dihydride complex, which loses H2 to generate [CpMo(CO)(κ3-PEtNMePEt)]+ at room temperature. CpMo(CO)(dppp)H (dppp = 1,2-bis(diphenylphosphino)propane) was studied as a Mo diphosphine analogue without a pendant amine, and the product of protonation of this complex gives [CpMo(CO)(dppp)(H)2]+. Our results show that the pendant amine has a strong driving force to form stable “tuck-in” [CpMo(CO)(κ3-PNP)]+ complexes, and also promotes hydrogen elimination from [CpMo(CO)(PNP)(H)2]+ complexes by formation of Mo-N dative bond. We thank the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Biosciences for support. Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy. We thank Monte Helm, Elliott Hulley and Deanna Miller for help on the crystallography, and Ming Fang for assistance on the electrochemical experiments.« less

  2. PET Timing Performance Measurement Method Using NEMA NEC Phantom

    NASA Astrophysics Data System (ADS)

    Wang, Gin-Chung; Li, Xiaoli; Niu, Xiaofeng; Du, Huini; Balakrishnan, Karthik; Ye, Hongwei; Burr, Kent

    2016-06-01

    When comparing the performance of time-of-flight whole-body PET scanners, timing resolution is one important benchmark. Timing performance is heavily influenced by detector and electronics design. Even for the same scanner design, measured timing resolution is a function of many factors including the activity concentration, geometry and positioning of the radioactive source. Due to lack of measurement standards, the timing resolutions reported in the literature may not be directly comparable and may not describe the timing performance under clinically relevant conditions. In this work we introduce a method which makes use of the data acquired during the standard NEMA Noise-Equivalent-Count-Rate (NECR) measurements, and compare it to several other timing resolution measurement methods. The use of the NEMA NEC phantom, with well-defined dimensions and radioactivity distribution, is attractive because it has been widely accepted in the industry and allows for the characterization of timing resolution across a more relevant range of conditions.

  3. Hydroxypyridinone Chelators: From Iron Scavenging to Radiopharmaceuticals for PET Imaging with Gallium-68

    PubMed Central

    Cusnir, Ruslan; Imberti, Cinzia; Hider, Robert C.; Blower, Philip J.; Ma, Michelle T.

    2017-01-01

    Derivatives of 3,4-hydroxypyridinones have been extensively studied for in vivo Fe3+ sequestration. Deferiprone, a 1,2-dimethyl-3,4-hydroxypyridinone, is now routinely used for clinical treatment of iron overload disease. Hexadentate tris(3,4-hydroxypyridinone) ligands (THP) complex Fe3+ at very low iron concentrations, and their high affinities for oxophilic trivalent metal ions have led to their development for new applications as bifunctional chelators for the positron emitting radiometal, 68Ga3+, which is clinically used for molecular imaging in positron emission tomography (PET). THP-peptide bioconjugates rapidly and quantitatively complex 68Ga3+ at ambient temperature, neutral pH and micromolar concentrations of ligand, making them amenable to kit-based radiosynthesis of 68Ga PET radiopharmaceuticals. 68Ga-labelled THP-peptides accumulate at target tissue in vivo, and are excreted largely via a renal pathway, providing high quality PET images. PMID:28075350

  4. Pharmaceutical development of a parenteral formulation of the novel anti-tumor agent carzelesin (U-80,244).

    PubMed

    Jonkman-de Vries, J D; de Graaff-Teulen, M J; Henrar, R E; Kettenes-van den Bosch, J J; Bult, A; Beijnen, J H

    1994-01-01

    The aim of this study was to design a parenteral dosage form for the investigational cytotoxic drug carzelesin. A stable formulation in PET (Polyethylene glycol 400/absolute ethanol/Tween 80, 6:3:1, v/v/v) was developed. The prototype, containing 0.50 mg carzelesin in 2.0 ml PET formulation, was found to be the optimal formulation in terms of solubility, stability and dosage requirements in phase I clinical trials. Quality control of the formulation showed that the pharmaceutical preparation of carzelesin in PET is not negatively influenced by the manufacturing process. Shelf life studies demonstrated that the formulation is stable for at least 1 year, when stored at -30 degrees C in the dark. In addition, the stability of carzelesin in the PET formulation is discussed as a function of temperature, additives and after dilution in infusion fluids.

  5. Hydroxypyridinone Chelators: From Iron Scavenging to Radiopharmaceuticals for PET Imaging with Gallium-68.

    PubMed

    Cusnir, Ruslan; Imberti, Cinzia; Hider, Robert C; Blower, Philip J; Ma, Michelle T

    2017-01-08

    Derivatives of 3,4-hydroxypyridinones have been extensively studied for in vivo Fe 3+ sequestration. Deferiprone, a 1,2-dimethyl-3,4-hydroxypyridinone, is now routinely used for clinical treatment of iron overload disease. Hexadentate tris(3,4-hydroxypyridinone) ligands (THP) complex Fe 3+ at very low iron concentrations, and their high affinities for oxophilic trivalent metal ions have led to their development for new applications as bifunctional chelators for the positron emitting radiometal, 68 Ga 3+ , which is clinically used for molecular imaging in positron emission tomography (PET). THP-peptide bioconjugates rapidly and quantitatively complex 68 Ga 3+ at ambient temperature, neutral pH and micromolar concentrations of ligand, making them amenable to kit-based radiosynthesis of 68 Ga PET radiopharmaceuticals. 68 Ga-labelled THP-peptides accumulate at target tissue in vivo, and are excreted largely via a renal pathway, providing high quality PET images.

  6. Characterization of an atmospheric pressure air plasma source for polymer surface modification

    NASA Astrophysics Data System (ADS)

    Yang, Shujun; Tang, Jiansheng

    2013-10-01

    An atmospheric pressure air plasma source was generated through dielectric barrier discharge (DBD). It was used to modify polyethyleneterephthalate (PET) surfaces with very high throughput. An equivalent circuit model was used to calculate the peak average electron density. The emission spectrum from the plasma was taken and the main peaks in the spectrum were identified. The ozone density in the down plasma region was estimated by Absorption Spectroscopy. NSF and ARC-ODU

  7. National Electrical Manufacturers Association NU-4 performance evaluation of the PET component of the NanoPET/CT preclinical PET/CT scanner.

    PubMed

    Szanda, Istvan; Mackewn, Jane; Patay, Gergely; Major, Peter; Sunassee, Kavitha; Mullen, Gregory E; Nemeth, Gabor; Haemisch, York; Blower, Philip J; Marsden, Paul K

    2011-11-01

    The NanoPET/CT represents the latest generation of commercial preclinical PET/CT systems. This article presents a performance evaluation of the PET component of the system according to the National Electrical Manufacturers Association (NEMA) NU-4 2008 standard. The NanoPET/CT consists of 12 lutetium yttrium orthosilicate:cerium modular detectors forming 1 ring, with 9.5-cm axial coverage and a 16-cm animal port. Each detector crystal is 1.12 × 1.12 × 13 mm, and 1 module contains 81 × 39 of these crystals. An optical light guide transmits the scintillation light to the flat-panel multianode position-sensitive photomultiplier tubes. Analog-to-digital converter cards and a field-programmable gate array-based data-collecting card provide the readout. Spatial resolution, sensitivity, counting rate capabilities, and image quality were evaluated in accordance with the NEMA NU-4 standard. Energy and temporal resolution measurements and a mouse imaging study were performed in addition to the standard. Energy resolution was 19% at 511 keV. The spatial resolution, measured as full width at half maximum on single-slice rebinning/filtered backprojection-reconstructed images, approached 1 mm on the axis and remained below 2.5 mm in the central 5-cm transaxial region both in the axial center and at one-quarter field of view. The maximum absolute sensitivity for a point source at the center of the field of view was 7.7%. The maximum noise equivalent counting rates were 430 kcps at 36 MBq and 130 kcps at 27 MBq for the mouse- and rat-sized phantoms, respectively. The uniformity and recovery coefficients were measured with the image-quality phantom, giving good-quality images. In a mouse study with an (18)F-labeled thyroid-specific tracer, the 2 lobes of the thyroid were clearly distinguishable, despite the small size of this organ. The flexible readout system allowed experiments to be performed in an efficient manner, and the system remained stable throughout. The large number of detector crystals, arranged with a fine pitch, results in excellent spatial resolution, which is the best reported for currently available commercial systems. The absolute sensitivity is high over the field of view. Combined with the excellent image quality, these features make the NanoPET/CT a powerful tool for preclinical research.

  8. Somatostatin receptor PET in neuroendocrine tumours: 68Ga-DOTA0,Tyr3-octreotide versus 68Ga-DOTA0-lanreotide.

    PubMed

    Putzer, Daniel; Kroiss, Alexander; Waitz, Dietmar; Gabriel, Michael; Traub-Weidinger, Tatjana; Uprimny, Christian; von Guggenberg, Elisabeth; Decristoforo, Clemens; Warwitz, Boris; Widmann, Gerlig; Virgolini, Irene Johanna

    2013-02-01

    The aim of this study was to evaluate the impact of (68)Ga-labelled DOTA(0)-lanreotide ((68)Ga-DOTA-LAN) on the diagnostic assessment of neuroendocrine tumour (NET) patients with low to moderate uptake on planar somatostatin receptor (SSTR) scintigraphy or (68)Ga-labelled DOTA(0),Tyr(3)-octreotide ((68)Ga-DOTA-TOC) positron emission tomography (PET). Fifty-three patients with histologically confirmed NET and clinical signs of progressive disease, who had not qualified for peptide receptor radionuclide therapy (PRRT) on planar SSTR scintigraphy or (68)Ga-DOTA-TOC PET (n = 38) due to lack of tracer uptake, underwent (68)Ga-DOTA-LAN PET to evaluate a treatment option with (90)Y-labelled lanreotide according to the MAURITIUS trial. The included patients received 150 ± 30 MBq of each radiopharmaceutical intravenously. PET scans were acquired 60-90 min after intravenous bolus injection. Image results from both PET scans were compared head to head, focusing on the intensity of tracer uptake in terms of treatment decision. CT was used for morphologic correlation of tumour lesions. To further evaluate the binding affinities of each tracer, quantitative and qualitative values were calculated for target lesions. (68)Ga-DOTA-LAN and (68)Ga-DOTA-TOC both showed equivalent findings in 24/38 patients when fused PET/CT images were interpreted. The sensitivity, specificity and accuracy of (68)Ga-DOTA-LAN in comparison to CT were 0.63, 0.5 and 0.62 (n = 53; p < 0.0001) and for (68)Ga-DOTA-TOC in comparison to CT 0.78, 0.5 and 0.76 (n = 38; p < 0.013), respectively. (68)Ga-DOTA-TOC showed a significantly higher maximum standardized uptake value (SUV(max)) regarding the primary tumour in 25 patients (p < 0.003) and regarding the liver in 30 patients (p < 0.009) compared to (68)Ga-DOTA-LAN. Corresponding values of both PET scans for tumour and liver did not show any significant correlation. (68)Ga-DOTA-TOC revealed more tumour sites than (68)Ga-DOTA-LAN (106 vs 53). The tumour to background ratios for tumour and liver calculated from SUV(max) measurements were significantly higher for (68)Ga-DOTA-TOC than (68)Ga-DOTA-LAN (p < 0.02). (68)Ga-DOTA-TOC PET imaging is an established imaging procedure for accurate staging of NET patients. (68)Ga-DOTA-LAN should only be considered as a PET tracer of second choice in patients with no pathologic tracer uptake on (68)Ga-DOTA-TOC PET. In these patients, (68)Ga-DOTA-LAN PET can provide valuable information when evaluating PRRT as the treatment option, as a broader spectrum of human SSTR subtypes can be detected.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremitymore » dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.« less

  10. 21 CFR 113.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... steam into the closed retort and the time when the retort reaches the required processing temperature..., school, penal, or other organization) processing of food, including pet food. Persons engaged in the... flames to achieve sterilization temperatures. A holding period in a heated section may follow the initial...

  11. Effect of urban design on microclimate and thermal comfort outdoors in warm-humid Dar es Salaam, Tanzania

    NASA Astrophysics Data System (ADS)

    Yahia, Moohammed Wasim; Johansson, Erik; Thorsson, Sofia; Lindberg, Fredrik; Rasmussen, Maria Isabel

    2018-03-01

    Due to the complexity of built environment, urban design patterns considerably affect the microclimate and outdoor thermal comfort in a given urban morphology. Variables such as building heights and orientations, spaces between buildings, plot coverage alter solar access, wind speed and direction at street level. To improve microclimate and comfort conditions urban design elements including vegetation and shading devices can be used. In warm-humid Dar es Salaam, the climate consideration in urban design has received little attention although the urban planning authorities try to develop the quality of planning and design. The main aim of this study is to investigate the relationship between urban design, urban microclimate, and outdoor comfort in four built-up areas with different morphologies including low-, medium-, and high-rise buildings. The study mainly concentrates on the warm season but a comparison with the thermal comfort conditions in the cool season is made for one of the areas. Air temperature, wind speed, mean radiant temperature (MRT), and the physiologically equivalent temperature (PET) are simulated using ENVI-met to highlight the strengths and weaknesses of the existing urban design. An analysis of the distribution of MRT in the areas showed that the area with low-rise buildings had the highest frequency of high MRTs and the lowest frequency of low MRTs. The study illustrates that areas with low-rise buildings lead to more stressful urban spaces than areas with high-rise buildings. It is also shown that the use of dense trees helps to enhance the thermal comfort conditions, i.e., reduce heat stress. However, vegetation might negatively affect the wind ventilation. Nevertheless, a sensitivity analysis shows that the provision of shade is a more efficient way to reduce PET than increases in wind speed, given the prevailing sun and wind conditions in Dar es Salaam. To mitigate heat stress in Dar es Salaam, a set of recommendations and guidelines on how to develop the existing situation from microclimate and thermal comfort perspectives is outlined. Such recommendations will help architects and urban designers to increase the quality of the outdoor environment and demonstrate the need to create better urban spaces in harmony with microclimate and thermal comfort.

  12. Effect of urban design on microclimate and thermal comfort outdoors in warm-humid Dar es Salaam, Tanzania.

    PubMed

    Yahia, Moohammed Wasim; Johansson, Erik; Thorsson, Sofia; Lindberg, Fredrik; Rasmussen, Maria Isabel

    2018-03-01

    Due to the complexity of built environment, urban design patterns considerably affect the microclimate and outdoor thermal comfort in a given urban morphology. Variables such as building heights and orientations, spaces between buildings, plot coverage alter solar access, wind speed and direction at street level. To improve microclimate and comfort conditions urban design elements including vegetation and shading devices can be used. In warm-humid Dar es Salaam, the climate consideration in urban design has received little attention although the urban planning authorities try to develop the quality of planning and design. The main aim of this study is to investigate the relationship between urban design, urban microclimate, and outdoor comfort in four built-up areas with different morphologies including low-, medium-, and high-rise buildings. The study mainly concentrates on the warm season but a comparison with the thermal comfort conditions in the cool season is made for one of the areas. Air temperature, wind speed, mean radiant temperature (MRT), and the physiologically equivalent temperature (PET) are simulated using ENVI-met to highlight the strengths and weaknesses of the existing urban design. An analysis of the distribution of MRT in the areas showed that the area with low-rise buildings had the highest frequency of high MRTs and the lowest frequency of low MRTs. The study illustrates that areas with low-rise buildings lead to more stressful urban spaces than areas with high-rise buildings. It is also shown that the use of dense trees helps to enhance the thermal comfort conditions, i.e., reduce heat stress. However, vegetation might negatively affect the wind ventilation. Nevertheless, a sensitivity analysis shows that the provision of shade is a more efficient way to reduce PET than increases in wind speed, given the prevailing sun and wind conditions in Dar es Salaam. To mitigate heat stress in Dar es Salaam, a set of recommendations and guidelines on how to develop the existing situation from microclimate and thermal comfort perspectives is outlined. Such recommendations will help architects and urban designers to increase the quality of the outdoor environment and demonstrate the need to create better urban spaces in harmony with microclimate and thermal comfort.

  13. Investigate the electrical and thermal properties of the low temperature resistant silver nanowire fabricated by two-beam laser technique

    NASA Astrophysics Data System (ADS)

    He, Gui-Cang; Dong, Xian-Zi; Liu, Jie; Lu, Heng; Zhao, Zhen-Sheng

    2018-05-01

    A two-beam laser fabrication technique is introduced to fabricate the single silver nanowire (AgNW) on polyethylene terephthalate (PET) substrate. The resistivity of the AgNW is (1.31 ± 0.05) × 10-7 Ω·m, which is about 8 times of the bulk silver resistivity (1.65 × 10-8 Ω·m). The AgNW electrical resistance is measured in temperature range of 10-300 K and fitted with the Bloch-Grüneisen formula. The fitting results show that the residue resistance is 153 Ω, the Debye temperature is 210 K and the electron-phonon coupling constant is (5.72 ± 0.24) × 10-8 Ω·m. Due to the surface scattering, the Debye temperature and the electron-phonon coupling constant are lower than those of bulk silver, and the residue resistance is bigger than that of bulk silver. Thermal conductivity of the single AgNW is calculated in the corresponding temperature range, which is the biggest at the temperature approaching the Debye temperature. The AgNW on PET substrate is the low temperature resistance material and is able to be operated stably at such a low temperature of 10 K.

  14. Synthesis of Diamond-Like Carbon Films on Planar and Non-Planar Geometries by the Atmospheric Pressure Plasma Chemical Vapor Deposition Method

    NASA Astrophysics Data System (ADS)

    Noborisaka, Mayui; Hirako, Tomoaki; Shirakura, Akira; Watanabe, Toshiyuki; Morikawa, Masashi; Seki, Masaki; Suzuki, Tetsuya

    2012-09-01

    Diamond-like carbon (DLC) films were synthesized by the dielectric barrier discharge-based plasma deposition at atmospheric pressure and their hardness and gas barrier properties were measured. A decrease in size of grains and heating substrate temperature improved nano-hardness up to 3.3 GPa. The gas barrier properties of DLC-coated poly(ethylene terephthalate) (PET) sheets were obtained by 3-5 times of non-coated PET with approximately 0.5 µm in film thickness. The high-gas-barrier DLC films deposited on PET sheets are expected to wrap elevated bridge of the super express and prevent them from neutralization of concrete. We also deposited DLC films inside PET bottles by the microwave surface-wave plasma chemical vapor deposition (CVD) method at near-atmospheric pressure. Under atmospheric pressure, the films were coated uniformly inside the PET bottles, but did not show high gas barrier properties. In this paper, we summarize recent progress of DLC films synthesized at atmospheric pressure with the aimed of food packaging and concrete pillar.

  15. Identifying outdoor thermal risk areas and evaluation of future thermal comfort concerning shading orientation in a traditional settlement.

    PubMed

    Huang, Kuo-Tsang; Yang, Shing-Ru; Matzarakis, Andreas; Lin, Tzu-Ping

    2018-06-01

    The outdoor thermal environment is expected to be deteriorated under climate change. An approach of risk identification including assessment from aspects of thermal stress effect, people's exposure, and local's vulnerability were adopted to study a hot-and-humid traditional rural community located at Tainan, Taiwan. Layers of each aspect were either constructed by in-situ measurements or simulations. To evaluate the future thermal comfort changes by simulations, the prerequisite hourly climate data of three future time slices were produced. Prognostic simulation model, ENVI-met, in combination with diagnostic model, RayMan, were respectively used for identifying current spatial distribution of thermal stress and for assessing the future thermal comfort changes. High thermal risk area was identified by superimposing layers of hazard, exposure and vulnerability. It revealed that because of the tourists' vulnerability to adapt local climate and the inflexibleness of choosing visiting time, it exhibited a high thermal stress at the Main Courtyard where its thermal comfort conditions will be deteriorated due to climate change. Furthermore, the thermal comfort conditions in various shading orientation were analyzed based on the changing climate in three future time slices, i.e. 2011-2040, 2041-2070, and 2071-2100. The results show the area with shading in the East and West side is more comfort than in the North side. In hot season, shading in the West side contributes less PET increasing, especially in the afternoon period. The severest overheat problem (the physiological equivalent temperature, PET>40°C) at the Main Courtyard will increase from current 10% to 28% in 2071-2100 in terms of overheating occurrence frequency. The results of this study can be used as the guidelines for environment analysis before planning or redesign community. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Influences of culture and environmental attitude on thermal, emotional and perceptual evaluations of a public square

    NASA Astrophysics Data System (ADS)

    Knez, Igor; Thorsson, Sofia

    2006-05-01

    The main objective of the present quasi-experimental study was to examine the influence of culture (Swedish vs Japanese) and environmental attitude (urban vs open-air person) on participants’ thermal, emotional and perceptual assessments of a square, within the PET (physiological equivalent temperature) comfortable interval of 18 23°C. It was predicted that persons living in different cultures with different environmental attitudes would psychologically evaluate a square differently despite similar thermal conditions. Consistent with this prediction, Japanese participants estimated the current weather as warmer than did Swedish participants and, consistent with this, they felt less thermally comfortable on the site, although participants in both countries perceived similar comfortable thermal outdoor conditions according to the PET index. Compared to the Japanese, the Swedes estimated both the current weather and the site as windier and colder, indicating a consistency in weather assessment on calm-windy and warm-cold scales in participants in both cultures. Furthermore, Swedish participants felt more glad and calm on the site and, in line with their character (more glad than gloomy), they estimated the square as more beautiful and pleasant than did Japanese participants. All this indicates that thermal, emotional and perceptual assessments of a physical place may be intertwined with psychological schema-based and socio-cultural processes, rather than fixed by general thermal indices developed in line with physiological heat balance models. In consequence, this implies that thermal comfort indices may not be applicable in different cultural/climate zones without modifications, and that they may not be appropriate if we do not take into account the psychological processes involved in environmental assessment.

  17. 7 CFR 58.236 - Pasteurization and heat treatment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... condensing at a minimum temperature of 161 °F. for at least 15 seconds or its equivalent in bacterial.... for 15 seconds or its equivalent in bacterial destruction. (2) All buttermilk to be used in the... temperature of 161 °F for 15 seconds or its equivalent in bacterial destruction. (b) Heat treatment—(1) High...

  18. Diphtheria toxin treatment of Pet-1-Cre floxed diphtheria toxin receptor mice disrupts thermoregulation without affecting respiratory chemoreception.

    PubMed

    Cerpa, V; Gonzalez, A; Richerson, G B

    2014-10-24

    In genetically-modified Lmx1b(f/f/p) mice, selective deletion of LMX1B in Pet-1 expressing cells leads to failure of embryonic development of serotonin (5-HT) neurons. As adults, these mice have a decreased hypercapnic ventilatory response and abnormal thermoregulation. This mouse model has been valuable in defining the normal role of 5-HT neurons, but it is possible that developmental compensation reduces the severity of observed deficits. Here we studied mice genetically modified to express diphtheria toxin receptors (DTR) on Pet-1 expressing neurons (Pet-1-Cre/floxed DTR or Pet1/DTR mice). These mice developed with a normal complement of 5-HT neurons. As adults, systemic treatment with 2-35μg of diphtheria toxin (DT) reduced the number of tryptophan hydroxylase-immunoreactive (TpOH-ir) neurons in the raphe nuclei and ventrolateral medulla by 80%. There were no effects of DT on minute ventilation (VE) or the ventilatory response to hypercapnia or hypoxia. At an ambient temperature (TA) of 24°C, all Pet1/DTR mice dropped their body temperature (TB) below 35°C after DT treatment, but the latency was shorter in males than females (3.0±0.37 vs. 4.57±0.29days, respectively; p<0.001). One week after DT treatment, mice were challenged by dropping TA from 37°C to 24°C, which caused TB to decrease more in males than in females (29.7±0.31°C vs. 33.0±1.3°C, p<0.01). We conclude that the 20% of 5-HT neurons that remain after DT treatment in Pet1/DTR mice are sufficient to maintain normal baseline breathing and a normal response to CO2, while those affected include some essential for thermoregulation, in males more than females. In comparison to models with deficient embryonic development of 5-HT neurons, acute deletion of 5-HT neurons in adults leads to a greater defect in thermoregulation, suggesting that significant developmental compensation can occur. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  19. Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors

    PubMed Central

    Peng, Hao; Levin, Craig S

    2013-01-01

    We studied the performance of a dual-panel positron emission tomography (PET) camera dedicated to breast cancer imaging using Monte Carlo simulation. The proposed system consists of two 4 cm thick 12 × 15 cm2 area cadmium zinc telluride (CZT) panels with adjustable separation, which can be put in close proximity to the breast and/or axillary nodes. Unique characteristics distinguishing the proposed system from previous efforts in breast-dedicated PET instrumentation are the deployment of CZT detectors with superior spatial and energy resolution, using a cross-strip electrode readout scheme to enable 3D positioning of individual photon interaction coordinates in the CZT, which includes directly measured photon depth-of-interaction (DOI), and arranging the detector slabs edge-on with respect to incoming 511 keV photons for high photon sensitivity. The simulation results show that the proposed CZT dual-panel PET system is able to achieve superior performance in terms of photon sensitivity, noise equivalent count rate, spatial resolution and lesion visualization. The proposed system is expected to achieve ~32% photon sensitivity for a point source at the center and a 4 cm panel separation. For a simplified breast phantom adjacent to heart and torso compartments, the peak noise equivalent count (NEC) rate is predicted to be ~94.2 kcts s−1 (breast volume: 720 cm3 and activity concentration: 3.7 kBq cm−3) for a ~10% energy window around 511 keV and ~8 ns coincidence time window. The system achieves 1 mm intrinsic spatial resolution anywhere between the two panels with a 4 cm panel separation if the detectors have DOI resolution less than 2 mm. For a 3 mm DOI resolution, the system exhibits excellent sphere resolution uniformity (σrms/mean) ≤ 10%) across a 4 cm width FOV. Simulation results indicate that the system exhibits superior hot sphere visualization and is expected to visualize 2 mm diameter spheres with a 5:1 activity concentration ratio within roughly 7 min imaging time. Furthermore, we observe that the degree of spatial resolution degradation along the direction orthogonal to the two panels that is typical of a limited angle tomography configuration is mitigated by having high-resolution DOI capabilities that enable more accurate positioning of oblique response lines. PMID:20400807

  20. Frequency of use controls chemical leaching from drinking-water containers subject to disinfection.

    PubMed

    Andra, Syam S; Makris, Konstantinos C; Shine, James P

    2011-12-15

    Microbial-, and chemical-based burden of disease associated with lack of access to safe water continues to primarily impact developing countries. Cost-effective health risk-mitigating measures, such as of solar disinfection applied to microbial-contaminated water stored in plastic bottles have been increasingly tested in developing countries adversely impacted by epidemic water-borne diseases. Public health concerns associated with chemical leaching from water packaging materials led us to investigate the magnitude and variability of antimony (Sb) and bromine (Br) leaching from reused plastic containers (polyethylene terephthalate, PET; and polycarbonate, PC) subject to UV and/or temperature-driven disinfection. The overall objective of this study was to determine the main and interactive effects of temperature, UV exposure duration, and frequency of bottle reuse on the extent of leaching of Sb and Br from plastic bottles into water. Regardless of UV exposure duration, frequency of reuse (up to 27 times) was the major factor that linearly increased Sb leaching from PET bottles at all temperatures tested (13-47 °C). Leached Sb concentrations (∼360 ng L(-1)) from the highly reused (27 times) PET bottles (minimal Sb leaching from PC bottles, <15 ng L(-1)) did not pose a serious risk to human health according to current daily Sb acceptable intake estimates. Leached Br concentrations from both PET and PC containers (up to ∼15 μg L(-1)) did not pose a consumer health risk either, however, no acceptable daily dose estimates exist for oral ingestion of organo-brominated, or other plasticizers/additives compounds if they were to be found in bottled water at much lower concentrations. Additional research on potential leaching of organic chemicals from water packaging materials is deemed necessary under relevant environmental conditions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Well-Balanced Ambipolar Conjugated Polymers Featuring Mild Glass Transition Temperatures Toward High-Performance Flexible Field-Effect Transistors.

    PubMed

    Shi, Keli; Zhang, Weifeng; Gao, Dong; Zhang, Shiying; Lin, Zuzhang; Zou, Ye; Wang, Liping; Yu, Gui

    2018-03-01

    Conjugated polymers, which can be fabricated by simple processing techniques and possess excellent electrical performance, are key to the fabrication of flexible polymer field-effect transistors (PFETs) and integrated circuits. Herein, two ambipolar conjugated polymers based on (3E,7E)-3,7-bis(2-oxo-1H-pyrrolo[2,3-b]pyridin-3(2H)-ylidene)benzo[1,2-b:4,5-b']difuran-2,6(3H,7H)-dione and dithienylbenzothiadiazole units, namely PNBDOPV-DTBT and PNBDOPV-DTF2BT, are developed. Both copolymers possess almost planar conjugated backbone conformations and suitable highest occupied molecular orbital (HOMO)/lowest unoccupied molecular orbital (LUMO) energy levels (-5.64/-4.38 eV for PNBDOPV-DTBT and -5.79/-4.48 eV for PNBDOPV-DTF2BT). Note that PNBDOPV-DTBT has a glass transition temperature (140 °C) lower than the deformation temperature of polyethylene terephthalate (PET), meaning well-ordered molecular packing can be obtained on PET substrate before its deformation in mild thermal annealing process. Flexible PFETs based on PNBDOPV-DTBT fabricated on PET substrates exhibit high and well-balanced hole/electron mobilities of 4.68/4.72 cm 2 V -1 s -1 under ambient conditions. After the further modification of Au source/drain electrodes with 1-octanethiol self-assembled monolayers, impressively high and well-balanced hole/electron mobilities up to 5.97/7.07 cm 2 V -1 s -1 are achieved in the flexible PFETs. Meanwhile, flexible complementary-like inverters based on PNBDOPV-DTBT on PET substrate also afford a much high gain of 148. The device performances of both the PFETs and inverters are among the highest values for ambipolar conjugated polymers reported to date. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. The Impact of Rendered Protein Meal Oxidation Level on Shelf-Life, Sensory Characteristics, and Acceptability in Extruded Pet Food.

    PubMed

    Chanadang, Sirichat; Koppel, Kadri; Aldrich, Greg

    2016-07-28

    Pet foods are expected to have a shelf-life for 12 months or more. Sensory analysis can be used to determine changes in products and to estimate products' shelf-life. The objectives of this study were to (1) investigate how increasing levels of oxidation in rendered protein meals used to produce extruded pet food affected the sensory properties and (2) determine the effect of shelf-life on pet owners' acceptability of extruded pet food diet formulated without the use of preservative. Pet food diets contained beef meat bone meal (BMBM) and chicken byproduct meal (CBPM) in which the oxidation was retarded with ethoxyquin, mixed tocopherols, or none at all, and then extruded into dry pet foods. These samples represented low, medium, and high oxidation levels, respectively. Samples were stored for 0, 3, 6, 9, and 12 months at ambient temperature. Each time point, samples were evaluated by six highly trained descriptive panelists for sensory attributes related to oxidation. Samples without preservatives were chosen for the acceptability test, since the differences in sensory characteristics over storage time were more distinguishable in those samples. Pet owners evaluated samples for aroma, appearance and overall liking. Descriptive sensory analysis detected significant changes in oxidized-related sensory characteristics over storage time. However, the differences for CBPM samples were more pronounced and directional. The consumer study showed no differences in pet owners' acceptability for BMBM samples. However, the noticeable increase in aroma characteristics (rancid aroma 0.33-4.21) in CBPM samples over storage time did have a negative effect on consumer's liking (overall liking 5.52-4.95).

  3. GSM mobile phone radiation suppresses brain glucose metabolism

    PubMed Central

    Kwon, Myoung Soo; Vorobyev, Victor; Kännälä, Sami; Laine, Matti; Rinne, Juha O; Toivonen, Tommi; Johansson, Jarkko; Teräs, Mika; Lindholm, Harri; Alanko, Tommi; Hämäläinen, Heikki

    2011-01-01

    We investigated the effects of mobile phone radiation on cerebral glucose metabolism using high-resolution positron emission tomography (PET) with the 18F-deoxyglucose (FDG) tracer. A long half-life (109 minutes) of the 18F isotope allowed a long, natural exposure condition outside the PET scanner. Thirteen young right-handed male subjects were exposed to a pulse-modulated 902.4 MHz Global System for Mobile Communications signal for 33 minutes, while performing a simple visual vigilance task. Temperature was also measured in the head region (forehead, eyes, cheeks, ear canals) during exposure. 18F-deoxyglucose PET images acquired after the exposure showed that relative cerebral metabolic rate of glucose was significantly reduced in the temporoparietal junction and anterior temporal lobe of the right hemisphere ipsilateral to the exposure. Temperature rise was also observed on the exposed side of the head, but the magnitude was very small. The exposure did not affect task performance (reaction time, error rate). Our results show that short-term mobile phone exposure can locally suppress brain energy metabolism in humans. PMID:21915135

  4. Scanning system, infrared noise equivalent temperature difference: Measurement procedure

    NASA Technical Reports Server (NTRS)

    Cannon, J. B., Jr.

    1975-01-01

    A procedure is described for determining the noise equivalent difference temperature for infrared electro-optical instruments. The instrumentation required, proper measurements, and methods of calculation are included.

  5. Interactive short-term effects of equivalent temperature and air pollution on human mortality in Berlin and Lisbon.

    PubMed

    Burkart, Katrin; Canário, Paulo; Breitner, Susanne; Schneider, Alexandra; Scherber, Katharina; Andrade, Henrique; Alcoforado, Maria João; Endlicher, Wilfried

    2013-12-01

    There is substantial evidence that both temperature and air pollution are predictors of mortality. Thus far, few studies have focused on the potential interactive effects between the thermal environment and different measures of air pollution. Such interactions, however, are biologically plausible, as (extreme) temperature or increased air pollution might make individuals more susceptible to the effects of each respective predictor. This study investigated the interactive effects between equivalent temperature and air pollution (ozone and particulate matter) in Berlin (Germany) and Lisbon (Portugal) using different types of Poisson regression models. The findings suggest that interactive effects exist between air pollutants and equivalent temperature. Bivariate response surface models and generalised additive models (GAMs) including interaction terms showed an increased risk of mortality during periods of elevated equivalent temperatures and air pollution. Cold effects were mostly unaffected by air pollution. The study underscores the importance of air pollution control in mitigating heat effects. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application.

    PubMed

    Karakatsanis, Nicolas A; Lodge, Martin A; Tahari, Abdel K; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ~15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ~45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically acceptable sampling schedules examined. The framework was also applied to six FDG PET patient studies, demonstrating clinical feasibility. Both simulated and clinical results indicated enhanced contrast-to-noise ratios (CNRs) for Ki images in tumor regions with notable background FDG concentration, such as the liver, where SUV performed relatively poorly. Overall, the proposed framework enables enhanced quantification of physiological parameters across the whole body. In addition, the total acquisition length can be reduced from 45 to ~35 min and still achieve improved or equivalent CNR compared to SUV, provided the true Ki contrast is sufficiently high. In the follow-up companion paper, a set of advanced linear regression schemes is presented to particularly address the presence of noise, and attempt to achieve a better trade-off between the mean-squared error and the CNR metrics, resulting in enhanced task-based imaging.

  7. Dynamic whole body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    PubMed Central

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Tahari, Abdel K.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-01-01

    Static whole body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single bed-coverage limiting the axial field-of-view to ~15–20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole body PET acquisition protocol of ~45min total length is presented, composed of (i) an initial 6-min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (6 passes x 7 bed positions, each scanned for 45sec). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares (OLS) Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of 10 different clinically acceptable sampling schedules examined. The framework was also applied to six FDG PET patient studies, demonstrating clinical feasibility. Both simulated and clinical results indicated enhanced contrast-to-noise ratios (CNRs) for Ki images in tumor regions with notable background FDG concentration, such as the liver, where SUV performed relatively poorly. Overall, the proposed framework enables enhanced quantification of physiological parameters across the whole-body. In addition, the total acquisition length can be reduced from 45min to ~35min and still achieve improved or equivalent CNR compared to SUV, provided the true Ki contrast is sufficiently high. In the follow-up companion paper, a set of advanced linear regression schemes is presented to particularly address the presence of noise, and attempt to achieve a better trade-off between the mean-squared error (MSE) and the CNR metrics, resulting in enhanced task-based imaging. PMID:24080962

  8. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    NASA Astrophysics Data System (ADS)

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Tahari, Abdel K.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-10-01

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ˜15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ˜45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically acceptable sampling schedules examined. The framework was also applied to six FDG PET patient studies, demonstrating clinical feasibility. Both simulated and clinical results indicated enhanced contrast-to-noise ratios (CNRs) for Ki images in tumor regions with notable background FDG concentration, such as the liver, where SUV performed relatively poorly. Overall, the proposed framework enables enhanced quantification of physiological parameters across the whole body. In addition, the total acquisition length can be reduced from 45 to ˜35 min and still achieve improved or equivalent CNR compared to SUV, provided the true Ki contrast is sufficiently high. In the follow-up companion paper, a set of advanced linear regression schemes is presented to particularly address the presence of noise, and attempt to achieve a better trade-off between the mean-squared error and the CNR metrics, resulting in enhanced task-based imaging.

  9. PET Using a GRPR Antagonist 68Ga-RM26 in Healthy Volunteers and Prostate Cancer Patients.

    PubMed

    Zhang, Jingjing; Niu, Gang; Fan, Xinrong; Lang, Lixin; Hou, Guozhu; Chen, Libo; Wu, Huanwen; Zhu, Zhaohui; Li, Fang; Chen, Xiaoyuan

    2018-06-01

    This study was designed to analyze the safety, biodistribution, and radiation dosimetry of a gastrin-releasing peptide receptor (GRPR) antagonist PET tracer, 68 Ga-RM26; to assess its clinical diagnostic value in prostate cancer patients; and to perform a direct comparison between GRPR antagonist 68 Ga-RM26 and agonist 68 Ga-BBN. Methods: Five healthy volunteers were enrolled to validate the safety of 68 Ga-RM26 and calculate dosimetry. A total of 28 patients with prostate cancer (17 newly diagnosed and 11 posttherapy) were recruited and provided written informed consent. All the cancer patients underwent PET/CT at 15-30 min after intravenous injection of 1.85 MBq (0.05 mCi) per kilogram of body weight of 68 Ga-RM26. Among them, 22 patients (11 newly diagnosed and 11 posttherapy) underwent 68 Ga-BBN PET/CT for comparison within 1 wk. 99m Tc-MDP (methylene diphosphonate) bone scans were obtained within 2 wk for comparison. GRPR immunohistochemical staining of tumor samples was performed. Results: The administration of 68 Ga-M26 was well tolerated by all subjects, with no adverse symptoms being noticed or reported during the procedure and at 2-wk follow-up. The total effective dose equivalent and effective dose were 0.0912 ± 0.0140 and 0.0657 ± 0.0124 mSv/MBq, respectively. In the 17 patients with newly diagnosed prostate cancer, 68 Ga-RM26 PET/CT showed positive prostate-confined findings in 15 tumors with an SUV max of 6.49 ± 2.37. In the 11 patients who underwent prostatectomy or brachytherapy with or without androgen deprivation therapy, 68 Ga-RM26 PET/CT detected 8 metastatic lymph nodes in 3 patients with an SUV max of 4.28 ± 1.25 and 21 bone lesions in 8 patients with an SUV max of 3.90 ± 3.07. Compared with 68 Ga-RM26 PET/CT, GRPR agonist 68 Ga-BBN PET/CT detected fewer primary lesions and lymph node metastases as well as demonstrated lower tracer accumulation. There was a significant positive correlation between SUV derived from 68 Ga-RM26 PET and the expression level of GRPR ( P < 0.001). Conclusion: This study indicates the safety and significant efficiency of GRPR antagonist 68 Ga-RM26. 68 Ga-RM26 PET/CT would have remarkable value in detecting both primary prostate cancer and metastasis. 68 Ga-RM26 is also expected to be better than GRPR agonist as an imaging marker to evaluate GRPR expression in prostate cancer. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  10. An approach to the usage of polyethylene terephthalate (PET) waste as roadway pavement material.

    PubMed

    Gürü, Metin; Çubuk, M Kürşat; Arslan, Deniz; Farzanian, S Ali; Bilici, İbrahim

    2014-08-30

    This study investigates an application area for Polyethylene Terephthalate (PET) bottle waste which has become an environmental problem in recent decades as being a considerable part of the total plastic waste bulk. Two novel additive materials, namely Thin Liquid Polyol PET (TLPP) and Viscous Polyol PET (VPP), were chemically derived from waste PET bottles and used to modify the base asphalt separately for this aim. The effects of TLPP and VPP on the asphalt and hot mix asphalt (HMA) mixture properties were detected through conventional tests (Penetration, Softening Point, Ductility, Marshall Stability, Nicholson Stripping) and Superpave methods (Rotational Viscosity, Dynamic Shear Rheometer (DSR), Bending Beam Rheometer (BBR)). Also, chemical structures were described by Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectrometer (EDS) and Fourier Transform Infrared (FTIR) techniques. Since TLPP and VPP were determined to improve the low temperature performance and fatigue resistance of the asphalt as well as the Marshall Stability and stripping resistance of the HMA mixtures based on the results of the applied tests, the usage of PET waste as an asphalt roadway pavement material offers an alternative and a beneficial way of disposal of this ecologically hazardous material. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Physical ageing of polyethylene terephthalate under natural sunlight: correlation study between crystallinity and mechanical properties

    NASA Astrophysics Data System (ADS)

    Aljoumaa, Khaled; Abboudi, Maher

    2016-01-01

    Semi-crystalline polyethylene terephthalate (PET) was aged under the effect of natural UV exposure and outdoor temperature during 670 days. The variation in the mechanical and thermal properties beside to the morphology was tracked by applying different analytical techniques, including scanning electron microscopy, infrared spectroscopy, differential scanning calorimetry and wide angle X-ray diffraction, in addition to tensile strength and hardness measurements. It has been confirmed that the ageing process is the results of physical trend only. The aged PET showed a decrease in both tensile strength and strain with an increase in the degree of crystallinity of aged PET samples during the whole period. These changes in crystallinity were examined by various analysis methods: density, calorimetric and infrared spectroscopy. New peaks in FTIR analysis at 1115 and 1090 cm-1 were characterized and proved that this technique is considered to be an easy tool to track the change in the surface crystallinity of aged PET samples directly. The results of this study showed that an augmentation in the degree of crystallinity of outdoor aged PET samples from 18 to 36 %, accompanied with a decrease in tensile strength from 167.9 to 133.7 MPa. Moreover, a good exponential correlation was found between the degree of crystallinity and the mechanical properties of the aged PET.

  12. Early Holocene vegetation - climate interactions in the central part of European Russia

    NASA Astrophysics Data System (ADS)

    Novenko, Elena; Olchev, Alexander

    2017-04-01

    The new Early Holocene vegetation and climate reconstruction (approximately 10100 -7800 cal. yr. BP) for the forest zone the central European Russia are based on pollen records from three key regions located in taiga, mixed coniferous-broadleaved and broadleaved forest zones. The climatic parameters (the mean annual temperature and precipitation) and total forest coverage during the early Holocene were reconstructed using the Best Modern Analogue technique. Information about moistening conditions was revealed from reconstructions of actual evapotranspiration (ET) and potential evaporation (PET). For calculation of the annual ET and PET rates of the forest landscapes a regression model was applied. The model is based on nonlinear approximations of annual values of ET and PET provided by the Levenberg-Marquardt method using the results of numerical simulations of ET and PET carried out by a Mixfor-SVAT model for the forests with different species compositions under various thermal and moistening conditions. Mixfor-SVAT is an one-dimensional model of the energy, H2O and CO2 exchange between vertically structured mono- and multi-specific forest stands and the atmosphere (Olchev et al., 2002). Obtained results showed that the considered period was characterized by relatively low air temperatures and high precipitation compared with modern conditions. Analysis of the long-term pattern of the mean annual temperature for all three regions reveal two synchronous significant cooling periods observed in 9100-9300 cal. yr. BP and 8100-8500 cal. yr. BP as well as rapid growth of the air temperature in 8100-7800 cal. yr. BP, when the annual temperatures increased by 3°C during about 300 years. The cooling phase of 8100-8500 cal. yr. BP could be corresponded to the distinct "8.2 ka event" widely recorded across Europe. Periods of climate warming are coincided with periods of precipitation rise whereas the cool phases are characterized by its decrease. The lowest ET and PET rates were obtained for northern sites in taiga and mixed coniferous-broadleaved forest zone. In particular during the cooling phases of 9100-9300 and 8100-8500 cal. yr. BP ET fell down to 220-230 mm per year and PET - to 400-410 mm year-1. For the southern region ET and PET were some higher but not exceeded 320 and 470 mm per year. The ratio of actual evapotranspiration and precipitation amount showed significant decrease of the ratio in period of cooling phases (down to 0.27). It can be a clear indicator of overwatering of the ground surface and high probability for mire formation. Relatively cold and moist climate provided relatively unfavorable conditions for forest growth. According to made reconstructions the birch and pine-birch woodlands spread over the vast area of European Russia during the Boreal and early Atlantic periods of the Holocene (10100-7900 cal. yr. BP). Forests occupied not more then 30-50% of the study area and dense forests situated only on the south of modern forest zone. The climate warming after 7900 cal. yr. BP was accomplished by expansion of broad-leaved tree species and significant increase of total forest coverage. This study was supported by the Russian Science Foundation (Grant 16-17-10045).

  13. PET bottle use patterns and antimony migration into bottled water and soft drinks: the case of British and Nigerian bottles.

    PubMed

    Tukur, Aminu; Sharp, Liz; Stern, Ben; Tizaoui, Chedly; Benkreira, Hadj

    2012-04-01

    While antimony has been reported to migrate from PET bottles into contents, reports on bottled water and soft drinks usage and PET bottle reuse patterns are currently unavailable in the literature. Bottle use conditions and patterns are important determinants of antimony migration. In this work a survey assessing the pattern of bottle use and reuse in Britain and Nigeria was undertaken. The survey findings influenced the design of laboratory experiments that assessed the migration of antimony from PET bottles into water and soft drinks. Typical storage durations for bottled contents between purchase and opening for use were 7 days or less. However storage of up to one year was reported. Bottle reuse was high and similar for the two countries with reuse durations being higher in Nigeria. The antimony concentration in 32 PET bottle materials from Britain and Nigeria were similar and ranged between 177 and 310 mg kg(-1). For 47 freshly purchased British bottled contents antimony concentration ranged between 0.03 and 6.61 μg L(-1) with only one sample exceeding the EU acceptable limit. Concentrations of Cd, Ge, Zn, Al, Be, Ti, Co and Pb were also measured. At realistic temperatures of 40 and 60 °C antimony concentration in deionised water in bottles remained below the EU acceptable limit even after 48 h exposure. The limit was exceeded for most exposures at 80 °C. Concentration of antimony in some bottled contents exceeded the EU limit after 11 months of storage at room temperature. Bottle aging and increase in bottle volume were associated with decreased migration of antimony from bottles.

  14. A New Fire Hazard for MR Imaging Systems: Blankets-Case Report.

    PubMed

    Bertrand, Anne; Brunel, Sandrine; Habert, Marie-Odile; Soret, Marine; Jaffre, Simone; Capeau, Nicolas; Bourseul, Laetitia; Dufour-Claude, Isabelle; Kas, Aurélie; Dormont, Didier

    2018-02-01

    In this report, a case of fire in a positron emission tomography (PET)/magnetic resonance (MR) imaging system due to blanket combustion is discussed. Manufacturing companies routinely use copper fibers for blanket fabrication, and these fibers may remain within the blanket hem. By folding a blanket with these copper fibers within an MR imaging system, one can create an electrical current loop with a major risk of local excessive heating, burn injury, and fire. This hazard applies to all MR imaging systems. Hybrid PET/MR imaging systems may be particularly vulnerable to this situation, because blankets are commonly used for fluorodeoxyglucose PET to maintain a normal body temperature and to avoid fluorodeoxyglucose uptake in brown adipose tissue. © RSNA, 2017.

  15. Bioinspired polyethylene terephthalate nanocone arrays with underwater superoleophobicity and anti-bioadhesion properties

    NASA Astrophysics Data System (ADS)

    Liu, Wendong; Liu, Xueyao; Fangteng, Jiaozi; Wang, Shuli; Fang, Liping; Shen, Huaizhong; Xiang, Siyuan; Sun, Hongchen; Yang, Bai

    2014-10-01

    This paper presents a facile method to fabricate bioinspired polyethylene terephthalate (PET) nanocone arrays via colloidal lithography. The aspect ratio (AR) of the nanocones can be finely modulated ranging from 1 to 6 by regulating the etching time. The samples with the AR value of 6 can present underwater superoleophobicity with the underwater oil contact angle (OCA) of 171.8°. The as-prepared PET nanocone arrays perform anti-bioadhesion behavior, which inhibits the formation of the actin cytoskeleton when it used as the substrate for cell culture. Moreover, the oil wettability is temperature controlled after modifying the PET nanocone arrays with PNIPAAm film, and the oil wettability of the functionalized nanocone arrays can be transformed from the superoleophobic state with OCA about 151° to the oleophilic state with OCA about 25° reversibly. Due to the high-throughput, parallel fabrication and cost-efficiency of this method, it will be favourable for researchers to introduce oleophobic properties to various substrate and device surfaces. Due to the superoleophobicity and simple functionalizing properties, the PET nanocone arrays are very promising surfaces for anti-adhesion, self-cleaning and have potential applications in material, medical, and biological fields.This paper presents a facile method to fabricate bioinspired polyethylene terephthalate (PET) nanocone arrays via colloidal lithography. The aspect ratio (AR) of the nanocones can be finely modulated ranging from 1 to 6 by regulating the etching time. The samples with the AR value of 6 can present underwater superoleophobicity with the underwater oil contact angle (OCA) of 171.8°. The as-prepared PET nanocone arrays perform anti-bioadhesion behavior, which inhibits the formation of the actin cytoskeleton when it used as the substrate for cell culture. Moreover, the oil wettability is temperature controlled after modifying the PET nanocone arrays with PNIPAAm film, and the oil wettability of the functionalized nanocone arrays can be transformed from the superoleophobic state with OCA about 151° to the oleophilic state with OCA about 25° reversibly. Due to the high-throughput, parallel fabrication and cost-efficiency of this method, it will be favourable for researchers to introduce oleophobic properties to various substrate and device surfaces. Due to the superoleophobicity and simple functionalizing properties, the PET nanocone arrays are very promising surfaces for anti-adhesion, self-cleaning and have potential applications in material, medical, and biological fields. Electronic supplementary information (ESI) available: The optical microscopy image of the self-assembled 2D PS microspheres over a large area, the diameter of the PS microsphere is 580 nm; The top-view SEM image of the PET nanocone arrays over a large area, the AR of the nanocone is 6; The SEM image of the PET nanocone arrays obtained after 30 min etching; The optical image of the water droplet on the PET nanocone arrays with an AR of 6; The schematic illustration of the nanocone arrays modification with PNIPAAm; High resolution XPS spectra of the PNIPAAm modified PET nanocone arrays. See DOI: 10.1039/c4nr04471a

  16. Simulation of Tracer Dose Reduction in 18F-FDG PET/MRI: Effects on Oncologic Reading, Image Quality, and Artifacts.

    PubMed

    Seith, Ferdinand; Schmidt, Holger; Kunz, Julia; Küstner, Thomas; Gatidis, Sergios; Nikolaou, Konstantin; la Fougère, Christian; Schwenzer, Nina

    2017-10-01

    The aim of our study was to evaluate the effect of stepwise-reduced doses on objective and subjective image parameters and on oncologic readings in whole-body 18 F-FDG PET/MRI. Methods: We retrospectively simulated the stepwise reduction of 18 F-FDG doses of 19 patients (mean age ± SD, 50.9 ± 11.7 y; mean body mass index ± SD, 22.8 ± 3.2 kg/m 2 ) who received a whole-body PET/MRI examination from 3 to 0.5 MBq/kg of body weight (kgBW) in intervals of 0.25. Objective imaging parameters were assessed by measuring the SUV and coefficient of variation in different regions (aorta, liver, spleen, kidney, small bowel, lumbar vertebra, psoas muscle, urinary bladder) as well as the noise-equivalent counting rates in each bed position. Subjective image quality was evaluated with a masked reading of each simulated PET compared with the dose of 2 MBq/kgBW. Oncologic reading was performed first according to PERCIST in each dose and second by defining malignant lesions in doses of 2 MBq/kgBW and the maximum dose image (gold standard). The diagnostic confidence of each lesion was measured using a Likert scale. Results: With decreasing doses, regions in the mid abdomen showed a stronger decrease of SUV mean and noise-equivalent counting rates than regions in the upper abdomen (SUV mean , -45% and -15% on average in the small bowel and the liver, respectively). The coefficient of variation showed a nonlinear increase, pronounced below 1.5 MBq/kgBW. Subjective image quality was stable over a range between 1.25 and 2.75 MBq/kgBW compared with 2 MBq/kgBW. However, large photopenic areas in the mid abdomen were observed in 2 patients. In the PERCIST reading, target lesions were above the liver threshold with a stable SUV peak in all cases down to 2 MBq/kgBW. Eighty-six of 90 lesions were identified correctly with a dose of 2 MBq/kgBW; Likert scores did not differ significantly. Conclusion: A reduction of doses in 18 F-FDG PET/MRI might be possible down to 2 MBq/kgBW in oncologic whole-body examinations. The image quality in the mid abdomen seems to be more affected by lower doses than in the upper abdomen, and in single cases large photopenic areas can occur. Therefore, we do not recommend reducing doses below 3 MBq/kgBW in adults at this time. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  17. The influence of urban design on outdoor thermal comfort in the hot, humid city of Colombo, Sri Lanka

    NASA Astrophysics Data System (ADS)

    Johansson, Erik; Emmanuel, Rohinton

    2006-11-01

    The outdoor environment is deteriorating in many tropical cities due to rapid urbanization. This leads to a number of problems related to health and well-being of humans and also negatively affects social and commercial outdoor activities. The creation of thermally comfortable microclimates in urban environments is therefore very important. This paper discusses the influence of street-canyon geometry on outdoor thermal comfort in Colombo, Sri Lanka. Five sites with different urban geometry, ground cover, and distance from the sea were studied during the warmest season. The environmental parameters affecting thermal comfort, viz. air temperature, humidity, wind speed, and solar radiation, were measured, and the thermal comfort was estimated by calculating the physiologically equivalent temperature (PET). The thermal comfort is far above the assumed comfort zone due to the combination of intense solar radiation, high temperatures, and low wind speeds, especially on clear days. The worst conditions were found in wide streets with low-rise buildings and no shade trees. The most comfortable conditions were found in narrow streets with tall buildings, especially if shade trees were present, as well as in areas near the coast where the sea breeze had a positive effect. In order to improve the outdoor comfort in Colombo, it is suggested to allow a more compact urban form with deeper street canyons and to provide additional shade through the use of trees, covered walkways, pedestrian arcades, etc. The opening up of the city’s coastal strip would allow the sea breeze to penetrate further into the city.

  18. The influence of urban design on outdoor thermal comfort in the hot, humid city of Colombo, Sri Lanka.

    PubMed

    Johansson, Erik; Emmanuel, Rohinton

    2006-11-01

    The outdoor environment is deteriorating in many tropical cities due to rapid urbanization. This leads to a number of problems related to health and well-being of humans and also negatively affects social and commercial outdoor activities. The creation of thermally comfortable microclimates in urban environments is therefore very important. This paper discusses the influence of street-canyon geometry on outdoor thermal comfort in Colombo, Sri Lanka. Five sites with different urban geometry, ground cover, and distance from the sea were studied during the warmest season. The environmental parameters affecting thermal comfort, viz. air temperature, humidity, wind speed, and solar radiation, were measured, and the thermal comfort was estimated by calculating the physiologically equivalent temperature (PET). The thermal comfort is far above the assumed comfort zone due to the combination of intense solar radiation, high temperatures, and low wind speeds, especially on clear days. The worst conditions were found in wide streets with low-rise buildings and no shade trees. The most comfortable conditions were found in narrow streets with tall buildings, especially if shade trees were present, as well as in areas near the coast where the sea breeze had a positive effect. In order to improve the outdoor comfort in Colombo, it is suggested to allow a more compact urban form with deeper street canyons and to provide additional shade through the use of trees, covered walkways, pedestrian arcades, etc. The opening up of the city's coastal strip would allow the sea breeze to penetrate further into the city.

  19. MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system.

    PubMed

    Omidvari, Negar; Topping, Geoffrey; Cabello, Jorge; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I

    2018-05-01

    Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out crystals with high-gain silicon photomultipliers (SiPMs) were studied with a small animal PET insert for a 7 T MRI system, in which the SiPM charge was transferred to outside the MRI scanner using coaxial cables. The interferences between the two systems were studied with three radio-frequency (RF) coil configurations. The effects of PET on the static magnetic field, flip angle distribution, RF noise, and image quality of various MRI sequences (gradient echo, spin echo, and echo planar imaging (EPI) at 1 H frequency, and chemical shift imaging at 13 C frequency) were investigated. The effects of fast-switching gradient fields and RF pulses on PET count rate were studied, while the PET insert and the readout electronics were not shielded. Operating the insert inside a 1 H volume coil, used for RF transmission and reception, limited the MRI to T1-weighted imaging, due to coil detuning and RF attenuation, and resulted in significant PET count loss. Using a surface receive coil allowed all tested MR sequences to be used with the insert, with 45-59% signal-to-noise ratio (SNR) degradation, compared to without PET. With a 1 H/ 13 C volume coil inside the insert and shielded by a copper tube, the SNR degradation was limited to 23-30% with all tested sequences. The insert did not introduce any discernible distortions into images of two tested EPI sequences. Use of truncated sinc shaped RF excitation pulses and gradient field switching had negligible effects on PET count rate. However, PET count rate was substantially affected by high-power RF block pulses and temperature variations due to high gradient duty cycles.

  20. Study of oxygen scavenging PET-based films activated by water

    NASA Astrophysics Data System (ADS)

    Rossi, Gabriella; Scarfato, Paola; Incarnato, Loredana

    2016-05-01

    In this work an active barrier system consisting of a thin and transparent film based on polyethylene terephthalate (PET) was studied. Dynamic oxygen absorption measurements were performed at different values of relative humidity and temperature, pointing out that humidity is a key factor in activating the oxidation of the polymer sample. Moreover, the thermal and optical properties of the films were investigated and a good correlation was found between the crystallinity increase and the consequent transparency reduction occurring after the oxygen absorption.

  1. Performance Evaluation of the microPET®—FOCUS-F120

    NASA Astrophysics Data System (ADS)

    Laforest, Richard; Longford, Desmond; Siegel, Stefan; Newport, Danny F.; Yap, Jeffrey

    2007-02-01

    microPETreg-Focus-F120 is the latest model of dedicated small animal PET scanners from CTI-Concorde Microsystems LLC, (Knoxville, TN). This scanner, based on the geometry of the microPET-R4, takes advantage of several detector modifications to the coincidence processing electronics that improve the image resolution, sensitivity, and counting rate performance as compared to the predecessor models. This work evaluates the performance of the Focus-F120 system and shows its improvement over the earlier models. In particular, the spatial resolution is shown to improve from 2.32 to 1.69 mm at 5 mm radial distance and the peak absolute sensitivity increases from 4.1% to 7.1% compared to the microPET-R4. The counting rate capability, expressed in noise equivalent counting rate (NEC-1R), was shown to peak at over 800 kcps at 88 MBq for both systems using a mouse phantom. For this small phantom, the NECR counting rate is limited by the data transmission bandwidth between the scanner and the acquisition console. The rat-like phantom showed peak NEC-1R value at 300 kcps at 140 MBq. Evaluation of image quality and quantitation accuracy was also performed using specially designed phantoms and animal experiments

  2. Evaluation of a high resolution silicon PET insert module

    NASA Astrophysics Data System (ADS)

    Grkovski, Milan; Brzezinski, Karol; Cindro, Vladimir; Clinthorne, Neal H.; Kagan, Harris; Lacasta, Carlos; Mikuž, Marko; Solaz, Carles; Studen, Andrej; Weilhammer, Peter; Žontar, Dejan

    2015-07-01

    Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm2 pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2-4.8 mm) filled with 18F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm).

  3. Impact of temperature and storage time on the migration of antimony from polyethylene terephthalate (PET) containers into bottled water in Qatar.

    PubMed

    Al-Otoum, Fatima; Al-Ghouti, Mohammad A; Costa, Ozeas S; Khraisheh, Majeda

    2017-11-12

    Prosperity in Qatar and the consequent stresses on water resources resulted in a sustainable increase in the bottled drinking water market. Reports on health concerns and possible migration of chemicals from the plastic material into the water have driven the current investigation. This study aims to address the extent of antimony (Sb) leaching from polyethylene terephthalate (PET) water bottles subject to temperature variations (24-50 °C) due to Qatar's hot climate and improper storage conditions. A representative basket including 66 different imported and locally produced water bottles was considered. The concentrations of Sb in bottled water ranged from 0.168 to 2.263 μg/L at 24 °C and from 0.240 to 6.110 μg/L at 50 °C. Antimony concentrations in PET bottles at 24 °C was significantly lower than those at 50 °C (p = 0.0142), indicating that the temperature was a principal factor affecting the release of Sb from the plastic into the water. Although the detected Sb amounts were below the guidelines endorsed by WHO and Qatar (standard 5 μg/L) at 24 °C, the concentration measured at 50 °C was higher than the recommended WHO values (6.11 μg/L).

  4. Temperature variations in a parked vehicle.

    PubMed

    Dadour, I R; Almanjahie, I; Fowkes, N D; Keady, G; Vijayan, K

    2011-04-15

    There were two reasons why this work was conducted. The first was to help determine the time of death of suicide and homicide victims inside vehicles. The second was to investigate the serious threat to life of children or pets left in stationary vehicles on a hot summers day. This paper demonstrates that when a vehicle is parked in the sun, temperature levels in the cabin of the vehicle can be more than 20°C above the ambient temperature. A simple 'greenhouse' model for predicting the daily internal vehicle temperatures, using readily available local meteorological data, was developed. This statistical model was calibrated using meteorological data and temperature data collected on parked vehicles over several summer seasons. The model uses environmental temperature and radiation data as input, and is shown to predict cabin temperatures to within about 1°C. Both the data collected and the model developed show that the temperature inside the cabin of a black vehicle is typically 5°C higher than that inside a white vehicle on a hot summer day. Also lowering the driver's window of the vehicle by 2.5 cm typically reduces cabin temperatures by about 3°C, which is not sufficient to reduce significantly the safety concerns for children or pets left in parked vehicles. Crown Copyright © 2010. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Sweet Polymers: Poly(2-ethyl-2-oxazoline) Glycopolymers by Reductive Amination.

    PubMed

    Mees, Maarten A; Effenberg, Christiane; Appelhans, Dietmar; Hoogenboom, Richard

    2016-12-12

    Carbohydrates are important in signaling, energy storage, and metabolism. Depending on their function, carbohydrates can be part of larger structures, such as glycoproteins, glycolipids, or other functionalities (glycoside). To this end, polymers can act as carriers of carbohydrates in so-called glycopolymers, which mimic the multivalent carbohydrate functionalities. We chose a biocompatible poly(2-ethyl-2-oxazoline) (PEtOx) as the basis for making glycopolymers. Via the partial hydrolysis of PEtOx, a copolymer of PEtOx and polyethylenimine (PEI) was obtained; the subsequent reductive amination with the linear forms of glucose and maltose yielded the glycopolymers. The ratios of PEtOx and carbohydrates were varied systematically, and the solution behaviors of the resulting glycoconjugates are discussed. Dynamic light scattering (DLS) revealed that, depending on the carbohydrate ratio, the glycopolymers were either fully water-soluble or formed agglomerates in a temperature-dependent manner. Finally, these polymers were tested for their biological availability by studying their lectin binding ability with Concanavalin A.

  6. A new method of estimating thermal performance of embryonic development rate yields accurate prediction of embryonic age in wild reptile nests.

    PubMed

    Rollinson, Njal; Holt, Sarah M; Massey, Melanie D; Holt, Richard C; Nancekivell, E Graham; Brooks, Ronald J

    2018-05-01

    Temperature has a strong effect on ectotherm development rate. It is therefore possible to construct predictive models of development that rely solely on temperature, which have applications in a range of biological fields. Here, we leverage a reference series of development stages for embryos of the turtle Chelydra serpentina, which was described at a constant temperature of 20 °C. The reference series acts to map each distinct developmental stage onto embryonic age (in days) at 20 °C. By extension, an embryo taken from any given incubation environment, once staged, can be assigned an equivalent age at 20 °C. We call this concept "Equivalent Development", as it maps the development stage of an embryo incubated at a given temperature to its equivalent age at a reference temperature. In the laboratory, we used the concept of Equivalent Development to estimate development rate of embryos of C. serpentina across a series of constant temperatures. Using these estimates of development rate, we created a thermal performance curve measured in units of Equivalent Development (TPC ED ). We then used the TPC ED to predict developmental stage of embryos in several natural turtle nests across six years. We found that 85% of the variation of development stage in natural nests could be explained. Further, we compared the predictive accuracy of the model based on the TPC ED to the predictive accuracy of a degree-day model, where development is assumed to be linearly related to temperature and the amount of accumulated heat is summed over time. Information theory suggested that the model based on the TPC ED better describes variation in developmental stage in wild nests than the degree-day model. We suggest the concept of Equivalent Development has several strengths and can be broadly applied. In particular, studies on temperature-dependent sex determination may be facilitated by the concept of Equivalent Development, as development age maps directly onto the developmental series of the organism, allowing critical periods of sex determination to be delineated without invasive sampling, even under fluctuating temperature. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. High-throughput multiple-mouse imaging with micro-PET/CT for whole-skeleton assessment.

    PubMed

    Yagi, Masashi; Arentsen, Luke; Shanley, Ryan M; Hui, Susanta K

    2014-11-01

    Recent studies have proven that skeleton-wide functional assessment is essential to comprehensively understand physiological aspects of the skeletal system. Therefore, in contrast to regional imaging studies utilizing a multiple-animal holder (mouse hotel), we attempted to develop and characterize a multiple-mouse imaging system with micro-PET/CT for high-throughput whole-skeleton assessment. Using items found in a laboratory, a simple mouse hotel that houses four mice linked with gas anesthesia was constructed. A mouse-simulating phantom was used to measure uniformity in a cross sectional area and flatness (Amax/Amin*100) along the axial, radial and tangential directions, where Amax and Amin are maximum and minimum activity concentration in the profile, respectively. Fourteen mice were used for single- or multiple-micro-PET/CT scans. NaF uptake was measured at eight skeletal sites (skull to tibia). Skeletal (18)F activities measured with mice in the mouse hotel were within 1.6 ± 4% (mean ± standard deviation) of those measured with mice in the single-mouse holder. Single-holder scanning yields slightly better uniformity and flatness over the hotel. Compared to use of the single-mouse holder, scanning with the mouse hotel reduced study time (by 65%), decreased the number of scans (four-fold), reduced cost, required less computer storage space (40%), and maximized (18)F usage. The mouse hotel allows high-throughput, quantitatively equivalent scanning compared to the single-mouse holder for micro-PET/CT imaging for whole-skeleton assessment of mice. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Experimental Investigation on Thermal Effects in Ultrasonic Joining of Thin Poly(ethylene terephthalate) Films Using Torsional Vibrations

    NASA Astrophysics Data System (ADS)

    Adachi, Kazunari; Uchiyama, Kenta; Kuriyama, Takashi; Miyata, Ken; Hisamatsu, Tokuro

    2009-11-01

    The authors previously determined that thermal effects are not a dominant factor in the ultrasonic joining of very low density polyethylene (VLDPE) films using torsional vibration. Now, to confirm that the plastic materials are not “melted” by mechanically generated heat in the joining, they have conducted joining experiments for thin poly(ethylene terephthalate) (PET) films. The temperature at the interface of two PET films of 0.1 mm thickness only increased to approximately 100 °C, and no trace of liquidation of the material was observed at the interface under a polarizing microscope. Investigation using a differential scanning calorimeter (DSC) revealed that the “melting point” of PET is about 260 °C, and an ultrasonically joined specimen showed no significant difference in thermal characteristics compared with an intact PET film. It was also determined that the PET films cannot be joined even after being pressed together for a period of 30 min or longer at approximately 150 °C. From the results obtained using the microscope and the DSC, the authors conclude that melting of the materials plays essentially no role in ultrasonic plastic joining.

  9. Recovery and normalization of triple coincidences in PET.

    PubMed

    Lage, Eduardo; Parot, Vicente; Moore, Stephen C; Sitek, Arkadiusz; Udías, Jose M; Dave, Shivang R; Park, Mi-Ae; Vaquero, Juan J; Herraiz, Joaquin L

    2015-03-01

    Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. To recover triple coincidences, the authors' method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. The addition of triple-coincidence events with the authors' method increased peak NEC rates of the scanner by 26.6% and 32% for mouse- and rat-sized objects, respectively. This increase in NEC-rate performance was also reflected in the image-quality metrics. Images reconstructed using double and triple coincidences recovered using their method had better signal-to-noise ratio than those obtained using only double coincidences, while preserving spatial resolution and contrast. Distribution of triple coincidences using an equal-weighting scheme increased apparent system sensitivity but degraded image quality. The performance boost provided by the inclusion of triple coincidences using their method allowed to reduce the acquisition time of standard imaging procedures by up to ∼25%. Recovering triple coincidences with the proposed method can effectively increase the sensitivity of current clinical and preclinical PET systems without compromising other parameters like spatial resolution or contrast.

  10. Development of a Body Shield for Small Animal PET System to Reduce Random and Scatter Coincidences

    NASA Astrophysics Data System (ADS)

    Wada, Yasuhiro; Yamamoto, Seiichi; Watanabe, Yasuyoshi

    2015-02-01

    For small animal positron emission tomography (PET) research using high radioactivity, such as dynamic studies, the resulting high random coincidence rate of the system degrades image quality. The random coincidence rate is increased not only by the gamma photons from inside the axial-field-of-view (axial-FOV) of the PET system but also by those from outside the axial-FOV. For brain imaging in small animal studies, significant interference is observed from gamma photons emitted from the body. Single gamma photons from the body enter the axial-FOV and increase the random and scatter coincidences. Shielding against the gamma photons from outside the axial-FOV would improve the image quality. For this purpose, we developed a body shield for a small animal PET system, the microPET Primate 4-ring system, and evaluated its performance. The body shield is made of 9-mm-thick lead and it surrounds most of a rat's body. We evaluated the effectiveness of the body shield using a head phantom and a body phantom with a radioactivity concentration ratio of 1:2 and a maximum total activity of approximately 250 MBq. The random coincidence rate was dramatically decreased to 1/10, and the noise equivalent count rate (NECR) was increased 6 times with an activity of 7 MBq in the head phantom. The true count rate was increased to 35% due to the decrease in system deadtime. The average scatter fraction was decreased to 1/2.5 with the body shield. Count rate measurements of rat were also conducted with an injection activity of approximately 25 MBq of [C-11]N,N-dimethyl-2-(2-amino-4-cyanophenylthio) benzylamine ([C-11]DASB) and approximately 70 and 310 MBq of 2-deoxy-2-(F-18)fluoro-D-glucose ([F-18]FDG). Using the body shield, [F-18]FDG images of rats were improved by increasing the amount of radioactivity injected. The body shield designed for small animal PET systems is a promising tool for improving image quality and quantitation accuracy in small animal molecular imaging research.

  11. Biodegradation of diethyl terephthalate (DET) and polyethylene terephthalate (PET) by a novel identified degrader Delftia sp. WL-3 and its proposed metabolic pathway.

    PubMed

    Liu, Jiawei; Xu, Guanbao; Dong, Weiliang; Xu, Ning; Xin, Fengxue; Ma, Jiangfeng; Fang, Yan; Zhou, Jie; Jiang, Min

    2018-06-01

    Polyethylene terephthalate (PET), a synthetic polyester material made of diethyl terephthalate (DET) monomers, is widely used in plastic products of daily life and caused serious pollution to the global environment. Microbial metabolism is the major degradation pathway responsible for DET degradation in natural soil; however, the microbial DET-degradation mechanism remains unclear. In this study, the newly isolated strain WL-3, identified as belonging to the genus Delftia, was found to be able to degrade 94% of 5 g·L -1 of DET and utilize it as the sole carbon source for growth within 7 days. Furthermore, strain WL-3 was capable of stable DET degradation under a wide range of pH values (6.0-9.0) and temperatures (20-42°C) with the optimal pH and temperature of 7.0 and 30°C respectively. Furthermore, the biochemical pathway of DET degradation by strain WL-3 was proposed based on the identified degradation intermediates. DET is first transformed into terephthalic acid (TPA) by the hydrolysis of two ester bonds, which is subsequently converted to protocatechuic acid (PCA) and further mineralized. SEM observations revealed obvious cracks on the surface of PET film after inoculation of 2 months with strain WL-3, indicating the strain's potential for the bioremediation of PET-contaminated environments. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  12. MR signal-fat-fraction analysis and T2* weighted imaging measure BAT reliably on humans without cold exposure.

    PubMed

    Holstila, Milja; Pesola, Marko; Saari, Teemu; Koskensalo, Kalle; Raiko, Juho; Borra, Ronald J H; Nuutila, Pirjo; Parkkola, Riitta; Virtanen, Kirsi A

    2017-05-01

    Brown adipose tissue (BAT) is compositionally distinct from white adipose tissue (WAT) in terms of triglyceride and water content. In adult humans, the most significant BAT depot is localized in the supraclavicular area. Our aim is to differentiate brown adipose tissue from white adipose tissue using fat T2* relaxation time mapping and signal-fat-fraction (SFF) analysis based on a commercially available modified 2-point-Dixon (mDixon) water-fat separation method. We hypothesize that magnetic resonance (MR) imaging can reliably measure BAT regardless of the cold-induced metabolic activation, with BAT having a significantly higher water and iron content compared to WAT. The supraclavicular area of 13 volunteers was studied on 3T PET-MRI scanner using T2* relaxation time and SFF mapping both during cold exposure and at ambient temperature; and 18 F-FDG PET during cold exposure. Volumes of interest (VOIs) were defined semiautomatically in the supraclavicular fat depot, subcutaneous WAT and muscle. The supraclavicular fat depot (assumed to contain BAT) had a significantly lower SFF and fat T2* relaxation time compared to subcutaneous WAT. Cold exposure did not significantly affect MR-based measurements. SFF and T2* values measured during cold exposure and at ambient temperature correlated inversely with the glucose uptake measured by 18 F-FDG PET. Human BAT can be reliably and safely assessed using MRI without cold activation and PET-related radiation exposure. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. What Is Insomnia?

    MedlinePlus

    ... sleep What distractions, such as a TV or computer, are in your bedroom To help your doctor, ... to limit possible distractions, such as a TV, computer, or pet. Make sure the temperature of your ...

  14. Thermal (dis)comfort experienced from physiological movements across indoor, transitional and outdoor spaces in Singapore: A pilot study

    NASA Astrophysics Data System (ADS)

    Li Heng, Su; Chow, Winston

    2017-04-01

    Human thermal comfort research is important as climate discomfort can adversely affect both health and work productivity in cities; however, such biometeorological work in low-latitude urban areas is still relatively unstudied hitherto. In the tropical metropolis of Singapore, a suite of policies have been implemented aimed at improving environmental sustainability via increasing car-free commutes and pedestrian movement during work/school journeys, with the consequence that individuals will likely have increased personal exposure through a variety of spaces (and climates) during typical daily activities. As such, research into exploring the thermal (dis)comfort experienced during pedestrian movements across these indoor, outdoor and transitional (semi-outdoor) spaces would yield interesting applied biometerological insights. This pilot study thus investigates how pedestrian thermal comfort varies spatially across a university campus, and how the physical intensity of pedestrian travel affects thermal comfort across these spaces. Over a 10-week period, we profiled six students for both their objective and subjective pedestrian thermal comfort during traverses across different spaces. Data were obtained through use of (a.) of a heat stress sensor, (b.) a fitness tracker, and (b.) a questionnaire survey to record traverse measurements of the microclimate, their physiological data, and their perceived microclimate comfort respectively. Measured climate and physiological data were used to derive commonly-used thermal comfort indices like wet-bulb globe temperature (WBGT) and physiological equivalent temperature (PET). Further, interviews were conducted with all six subjects at the end of the fieldwork period to ascertain details on individual acclimatization behavior and adaptation strategies. The results indicate that (a.) more than 50% of the microclimatic conditions within each indoor, semi-outdoor, and outdoor space exceeded heat stress thresholds of both PET and WBGT, and that participants often were at "high" risk of heat stress from pedestrian movement; (b.) participants were most comfortable with humidity sensations across all spaces compared to other microclimate sensations (e.g. wind, heat, sun); (c.) correlation between microclimate sensation and WBGT varied across participants and across spaces, with stronger correlation between sun sensation votes and WBGT for most participants, and (d.) heart rates of individuals were not significant in estimating and predicting PET for activities such as pedestrian walking. Present results confirm that WBGT applies better to hot climates and outdoor thermal comfort, but not so for hot, humid climates and indoor thermal comfort. Self-reported (subjective) thermal comfort also differed from measured (objective) thermal comfort and across participants because acclimatized individuals can have different sensitivities and acceptance towards (dis)comfort arising from pedestrian movement across spaces. Finally, we suggest that future pedestrian thermal comfort studies employ longitudinal studies and traverse measurements to consider the critical aspects of thermal history and individual sensitivities to on (dis)comfort levels.

  15. Highly transparent, stable, and superhydrophobic coatings based on gradient structure design and fast regeneration from physical damage

    NASA Astrophysics Data System (ADS)

    Chen, Zao; Liu, Xiaojiang; Wang, Yan; Li, Jun; Guan, Zisheng

    2015-12-01

    Optical transparency, mechanical flexibility, and fast regeneration are important factors to expand the application of superhydrophobic surfaces. Herein, we fabricated highly transparent, stable, and superhydrophobic coatings through a novel gradient structure design by versatile dip-coating of silica colloid particles (SCPs) and diethoxydimethysiliane cross-linked silica nanoparticles (DDS-SNPs) on polyethylene terephthalate (PET) film and glass, followed by the modification of octadecyltrichlorosiliane (OTCS). When the DDS concentration reached 5 wt%, the modified SCPs/DDS-SNPs coating exhibited a water contact angle (WCA) of 153° and a sliding angle (SA) <5°. Besides, the average transmittance of this superhydrophobic coating on PET film and glass was increased by 2.7% and 1% in the visible wavelength, respectively. This superhydrophobic coating also showed good robustness and stability against water dropping impact, ultrasonic damage, and acid solution. Moreover, the superhydrophobic PET film after physical damage can quickly regain the superhydrophobicity by one-step spray regenerative solution of dodecyltrichlorosilane (DTCS) modified silica nanoparticles at room temperature. The demonstrated method for the preparation and regeneration of superhydrophobic coating is available for different substrates and large-scale production at room temperature.

  16. Whole-body biodistribution and brain PET imaging with [18F]AV-45, a novel amyloid imaging agent--a pilot study.

    PubMed

    Lin, Kun-Ju; Hsu, Wen-Chuin; Hsiao, Ing-Tsung; Wey, Shiaw-Pyng; Jin, Lee-Way; Skovronsky, Daniel; Wai, Yau-Yau; Chang, Hsiu-Ping; Lo, Chuan-Wei; Yao, Cheng Hsiang; Yen, Tzu-Chen; Kung, Mei-Ping

    2010-05-01

    The compound (E)-4-(2-(6-(2-(2-(2-(18)F-fluoroethoxy)ethoxy)ethoxy) pyridin-3-yl)vinyl)-N-methylbenzenamine ([(18)F]AV-45) is a novel radiopharmaceutical capable of selectively binding to beta-amyloid (A beta) plaques. This pilot study reports the safety, biodistribution, and radiation dosimetry of [(18)F]AV-45 in human subjects. In vitro autoradiography and fluorescent staining of postmortem brain tissue from patients with Alzheimer's disease (AD) and cognitively healthy subjects were performed to assess the specificity of the tracer. Biodistribution was assessed in three healthy elderly subjects (mean age: 60.0+/-5.2 years) who underwent 3-h whole-body positron emission tomography (PET)/computed tomographic (CT) scans after a bolus injection of 381.9+/-13.9 MBq of [(18)F]AV-45. Another six subjects (three AD patients and three healthy controls, mean age: 67.7+/-13.6 years) underwent brain PET studies. Source organs were delineated on PET/CT. All subjects underwent magnetic resonance imaging (MRI) for obtaining structural information. In vitro autoradiography revealed exquisitely high specific binding of [(18)F]AV-45 to postmortem AD brain sections, but not to the control sections. There were no serious adverse events throughout the study period. The peak uptake of the tracer in the brain was 5.12+/-0.41% of the injected dose. The highest absorbed organ dose was to the gallbladder wall (184.7+/-78.6 microGy/MBq, 4.8 h voiding interval). The effective dose equivalent and effective dose values for [(18)F]AV-45 were 33.8+/-3.4 microSv/MBq and 19.3+/-1.3 microSv/MBq, respectively. [(18)F]AV-45 binds specifically to A beta in vitro, and is a safe PET tracer for studying A beta distribution in human brain. The dosimetry is suitable for clinical and research application. (c) 2010 Elsevier Inc. All rights reserved.

  17. Optimization of transmission scan duration for 15O PET study with sequential dual tracer administration using N-index.

    PubMed

    Kudomi, Nobuyuki; Watabe, Hiroshi; Hayashi, Takuya; Oka, Hisashi; Miyake, Yoshinori; Iida, Hidehiro

    2010-06-01

    Cerebral blood flow (CBF), oxygen extraction fraction (OEF) and cerebral metabolic rate of O(2) (CMRO(2)) can be quantified by PET with the administration of H (2) (15) O and (15)O(2). Recently, a shortening in the duration of these measurements was achieved by the sequential administration of dual tracers of (15)O(2) and H (2) (15) O with PET acquisition and integration method (DARG method). A transmission scan is generally required for correcting photon attenuation in advance of PET scan. Although the DARG method can shorten the total study duration to around 30 min, the transmission scan duration has not been optimized and has possibility to shorten its duration. Our aim of this study was to determine the optimal duration for the transmission scan. We introduced 'N-index', which estimates the noise level on an image obtained by subtracting two statistically independent and physiologically equivalent images. The relationship between noise on functional images and duration of the transmission scan was investigated by N-index. We performed phantom studies to test whether the N-index reflects the pixel noise in a PET image. We also estimated the noise level by the N-index on CBF, OEF and CMRO(2) images from DARG method in clinical patients, and investigated an optimal true count of the transmission scan. We found tight correlation between pixel noise and N-index in the phantom study. By investigating relationship between the transmission scan duration and N-index value for the functional images by DARG method, we revealed that the transmission data with true counts of more than 40 Mcounts results in CBF, OEF, and CMRO(2) images of reasonable quantitative accuracy and quality. The present study suggests that further shortening of DARG measurement is possible by abridging the transmission scan. The N-index could be used to determine the optimal measurement condition when examining the quality of image.

  18. Observations Regarding Scatter Fraction and NEC Measurements for Small Animal PET

    NASA Astrophysics Data System (ADS)

    Yang, Yongfeng; Cherry, S. R.

    2006-02-01

    The goal of this study was to evaluate the magnitude and origin of scattered radiation in a small-animal PET scanner and to assess the impact of these findings on noise equivalent count rate (NECR) measurements, a metric often used to optimize scanner acquisition parameters and to compare one scanner with another. The scatter fraction (SF) was measured for line sources in air and line sources placed within a mouse-sized phantom (25 mm /spl phi//spl times/70 mm) and a rat-sized phantom (60 mm /spl phi//spl times/150 mm) on the microPET II small-animal PET scanner. Measurements were performed for lower energy thresholds ranging from 150-450 keV and a fixed upper energy threshold of 750 keV. Four different methods were compared for estimating the SF. Significant scatter fractions were measured with just the line source in the field of view, with the spatial distribution of these events consistent with scatter from the gantry and room environment. For mouse imaging, this component dominates over object scatter, and the measured SF is strongly method dependent. The environmental SF rapidly increases as the lower energy threshold decreases and can be more than 30% for an open energy window of 150-750 keV. The object SF originating from the mouse phantom is about 3-4% and does not change significantly as the lower energy threshold increases. The object SF for the rat phantom ranges from 10 to 35% for different energy windows and increases as the lower energy threshold decreases. Because the measured SF is highly dependent on the method, and there is as yet no agreed upon standard for animal PET, care must be exercised when comparing NECR for small objects between different scanners. Differences may be methodological rather than reflecting any relevant difference in the performance of the scanner. Furthermore, these results have implications for scatter correction methods when the majority of the detected scatter does not arise from the object itself.

  19. Changes in climate suitability for tourism at Adriatic coast since 1961

    NASA Astrophysics Data System (ADS)

    Zaninovic, Ksenija

    2017-04-01

    The aim of the paper is the comparison of suitability of climate conditions for tourism at the eastern Adriatic coast in the period 1961-2015. For quantitative estimation of suitability of climate for different kinds of tourism, climate index for tourism (CIT) is used. CIT integrates thermal, aesthetic and physical facets of atmospheric environment and therefore is suitable for estimation of climate satisfaction that ranges from very poor to very good. The thermal component is estimated using the physiologically equivalent temperature (PET). The index is applied for: beach tourism, cycling, hiking, cultural tourism, golf, football, motor boating and sailing. Changes in climate potential of tourism are estimated by differences of distribution of climate index for tourism. For the warmest part of the day, the results indicate the extension of the summer tourist season for beach tourism at the end of the analyzed period. On the other hand, for other tourist activities in the same period the results indicate more pronounced bimodal distribution of CIT during year, resulting with the seasonality shift of ideal conditions for most activities to spring and autumn. Besides, in the morning the improvement of favourable climate conditions for all types of tourism at the end of the period.

  20. Timing Calibration in PET Using a Time Alignment Probe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moses, William W.; Thompson, Christopher J.

    2006-05-05

    We evaluate the Scanwell Time Alignment Probe for performing the timing calibration for the LBNL Prostate-Specific PET Camera. We calibrate the time delay correction factors for each detector module in the camera using two methods--using the Time Alignment Probe (which measures the time difference between the probe and each detector module) and using the conventional method (which measures the timing difference between all module-module combinations in the camera). These correction factors, which are quantized in 2 ns steps, are compared on a module-by-module basis. The values are in excellent agreement--of the 80 correction factors, 62 agree exactly, 17 differ bymore » 1 step, and 1 differs by 2 steps. We also measure on-time and off-time counting rates when the two sets of calibration factors are loaded into the camera and find that they agree within statistical error. We conclude that the performance using the Time Alignment Probe and conventional methods are equivalent.« less

  1. Matching the decay half-life with the biological half-life: ImmunoPET imaging with 44 Sc-labeled Cetuximab Fab fragment

    DOE PAGES

    Chakravarty, Rubel; Goel, Shreya; Valdovinos, Hector F.; ...

    2014-11-11

    Scandium-44 (t 1/2 = 3.9 h) is a relatively new radioisotope of potential interest for use in clinical positron emission tomography (PET). Herein, we report, for the first time, the room-temperature radiolabeling of proteins with 44Sc for in vivo PET imaging. For this purpose, the Fab fragment of Cetuximab, a monoclonal antibody that binds with high affinity to epidermal growth factor receptor (EGFR), was generated and conjugated with N-[(R)-2-amino-3-( para-isothiocyanato-phenyl)propyl]- trans-(S,S)-cyclohexane-1,2-diamine- N,N,N',N'',N''-pentaacetic acid (CHX-A"-DTPA). The high purity of Cetuximab-Fab was confirmed by SDS-PAGE and mass spectrometry. The potential of the bioconjugate for PET imaging of EGFR expression in human glioblastomamore » (U87MG) tumor-bearing mice was investigated after 44Sc labeling. PET imaging revealed rapid tumor uptake (maximum uptake of ~12% ID/g at 4 h postinjection) of 44Sc–CHX-A"-DTPA–Cetuximab-Fab with excellent tumor-to-background ratio, which might allow for same day PET imaging in future clinical studies. Immunofluorescence staining was conducted to correlate tracer uptake in the tumor and normal tissues with EGFR expression. As a result, this successful strategy for immunoPET imaging of EGFR expression using 44Sc–CHX-''-DTPA–Cetuximab-Fab can make clinically translatable advances to select the right population of patients for EGFR-targeted therapy and also to monitor the therapeutic efficacy of anti-EGFR treatments.« less

  2. Scaling Potential Evapotranspiration with Greenhouse Warming (Invited)

    NASA Astrophysics Data System (ADS)

    Scheff, J.; Frierson, D. M.

    2013-12-01

    Potential evapotranspiration (PET) is a supply-independent measure of the evaporative demand of a terrestrial climate, of basic importance in climatology, hydrology, and agriculture. Future increases in PET from greenhouse warming are often cited as key drivers of global trends toward drought and aridity. The present work computes recent and business-as-usual-future Penman-Monteith (i.e. physically-based) PET fields at 3-hourly resolution in 14 modern global climate models. The %-change in local annual-mean PET over the upcoming century is almost always positive, modally low double-digit in magnitude, usually increasing with latitude, yet quite divergent between models. These patterns are understood as follows. In every model, the global field of PET %-change is found to be dominated by the direct, positive effects of constant-relative-humidity warming (via increasing vapor pressure deficit and increasing Clausius-Clapeyron slope.) This direct-warming term very accurately scales as the PET-weighted (warm-season daytime) local warming, times 5-6% per degree (related to the Clausius-Clapeyron equation), times an analytic factor ranging from about 0.25 in warm climates to 0.75 in cold climates, plus a small correction. With warming of several degrees, this product is of low double-digit magnitude, and the strong temperature dependence gives the latitude dependence. Similarly, the inter-model spread in the amount of warming gives most of the spread in this term. Additional spread in the total change comes from strong disagreement on radiation, relative-humidity, and windspeed changes, which make smaller yet substantial contributions to the full PET %-change fields.

  3. Matching the Decay Half-Life with the Biological Half-Life: ImmunoPET Imaging with 44Sc-Labeled Cetuximab Fab Fragment

    PubMed Central

    2015-01-01

    Scandium-44 (t1/2 = 3.9 h) is a relatively new radioisotope of potential interest for use in clinical positron emission tomography (PET). Herein, we report, for the first time, the room-temperature radiolabeling of proteins with 44Sc for in vivo PET imaging. For this purpose, the Fab fragment of Cetuximab, a monoclonal antibody that binds with high affinity to epidermal growth factor receptor (EGFR), was generated and conjugated with N-[(R)-2-amino-3-(para-isothiocyanato-phenyl)propyl]-trans-(S,S)-cyclohexane-1,2-diamine-N,N,N′,N″,N″-pentaacetic acid (CHX-A″-DTPA). The high purity of Cetuximab-Fab was confirmed by SDS-PAGE and mass spectrometry. The potential of the bioconjugate for PET imaging of EGFR expression in human glioblastoma (U87MG) tumor-bearing mice was investigated after 44Sc labeling. PET imaging revealed rapid tumor uptake (maximum uptake of ∼12% ID/g at 4 h postinjection) of 44Sc–CHX-A″-DTPA–Cetuximab-Fab with excellent tumor-to-background ratio, which might allow for same day PET imaging in future clinical studies. Immunofluorescence staining was conducted to correlate tracer uptake in the tumor and normal tissues with EGFR expression. This successful strategy for immunoPET imaging of EGFR expression using 44Sc–CHX-A″-DTPA–Cetuximab-Fab can make clinically translatable advances to select the right population of patients for EGFR-targeted therapy and also to monitor the therapeutic efficacy of anti-EGFR treatments. PMID:25389697

  4. Effect of temperature oscillation on thermal characteristics of an aluminum thin film

    NASA Astrophysics Data System (ADS)

    Ali, H.; Yilbas, B. S.

    2014-12-01

    Energy transport in aluminum thin film is examined due to temperature disturbance at the film edge. Thermal separation of electron and lattice systems is considered in the analysis, and temperature variation in each sub-system is formulated. The transient analysis of frequency-dependent and frequency-independent phonon radiative transport incorporating electron-phonon coupling is carried out in the thin film. The dispersion relations of aluminum are used in the frequency-dependent analysis. Temperature at one edge of the film is oscillated at various frequencies, and temporal response of phonon intensity distribution in the film is predicted numerically using the discrete ordinate method. To assess the phonon transport characteristics, equivalent equilibrium temperature is introduced. It is found that equivalent equilibrium temperature in the electron and lattice sub-systems oscillates due to temperature oscillation at the film edge. The amplitude of temperature oscillation reduces as the distance along the film thickness increases toward the low-temperature edge of the film. Equivalent equilibrium temperature attains lower values for the frequency-dependent solution of the phonon transport equation than that corresponding to frequency-independent solution.

  5. Suitability of different comfort indices for the prediction of thermal conditions in tree-covered outdoor spaces in arid cities

    NASA Astrophysics Data System (ADS)

    Ruiz, María Angélica; Correa, Erica Norma

    2015-10-01

    Outdoor thermal comfort is one of the most influential factors in the habitability of a space. Thermal level is defined not only by climate variables but also by the adaptation of people to the environment. This study presents a comparison between inductive and deductive thermal comfort models, contrasted with subjective reports, in order to identify which of the models can be used to most correctly predict thermal comfort in tree-covered outdoor spaces of the Mendoza Metropolitan Area, an intensely forested and open city located in an arid zone. Interviews and microclimatic measurements were carried out in winter 2010 and in summer 2011. Six widely used indices were selected according to different levels of complexity: the Temperature-Humidity Index (THI), Vinje's Comfort Index (PE), Thermal Sensation Index (TS), the Predicted Mean Vote (PMV), the COMFA model's energy balance (S), and the Physiological Equivalent Temperature (PET). The results show that the predictive models evaluated show percentages of predictive ability lower than 25 %. Despite this low indicator, inductive methods are adequate for obtaining a diagnosis of the degree and frequency in which a space is comfortable or not whereas deductive methods are recommended to influence urban design strategies. In addition, it is necessary to develop local models to evaluate perceived thermal comfort more adequately. This type of tool is very useful in the design and evaluation of the thermal conditions in outdoor spaces, based not only to climatic criteria but also subjective sensations.

  6. MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system

    NASA Astrophysics Data System (ADS)

    Omidvari, Negar; Topping, Geoffrey; Cabello, Jorge; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I.

    2018-05-01

    Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out crystals with high-gain silicon photomultipliers (SiPMs) were studied with a small animal PET insert for a 7 T MRI system, in which the SiPM charge was transferred to outside the MRI scanner using coaxial cables. The interferences between the two systems were studied with three radio-frequency (RF) coil configurations. The effects of PET on the static magnetic field, flip angle distribution, RF noise, and image quality of various MRI sequences (gradient echo, spin echo, and echo planar imaging (EPI) at 1H frequency, and chemical shift imaging at 13C frequency) were investigated. The effects of fast-switching gradient fields and RF pulses on PET count rate were studied, while the PET insert and the readout electronics were not shielded. Operating the insert inside a 1H volume coil, used for RF transmission and reception, limited the MRI to T1-weighted imaging, due to coil detuning and RF attenuation, and resulted in significant PET count loss. Using a surface receive coil allowed all tested MR sequences to be used with the insert, with 45–59% signal-to-noise ratio (SNR) degradation, compared to without PET. With a 1H/13C volume coil inside the insert and shielded by a copper tube, the SNR degradation was limited to 23–30% with all tested sequences. The insert did not introduce any discernible distortions into images of two tested EPI sequences. Use of truncated sinc shaped RF excitation pulses and gradient field switching had negligible effects on PET count rate. However, PET count rate was substantially affected by high-power RF block pulses and temperature variations due to high gradient duty cycles.

  7. Tailoring the physical properties of homopolymers and polymer nanocomposites via solid-state processing

    NASA Astrophysics Data System (ADS)

    Pierre, Cynthia

    Numerous approaches can be used to modify polymer properties. In this thesis, it is demonstrated that an innovative, continuous, industrially scalable process called solid-state shear pulverization (SSSP) can be used to enhance polymer properties with and without the addition of nanofillers. The SSSP process employs a modified twin-screw extruder in which the barrel is cooled rather than heated, resulting in the polymer being processed at a temperature below its glass transition temperature, if the polymer is amorphous, or its melt transition temperature, if the polymer is semi-crystalline. The material processed via SSSP experiences high levels of shear and compressive stresses, resulting in many repeated fragmentation and fusion steps during pulverization, which can lead to mechanochemistry. This research provides the first in-depth study on the effect of SSSP processing on the molecular structure as well as physical properties of homopolymers. Rheological characterization has demonstrated an increase in the melt viscosity of pulverized poly(ethylene terephthalate) (PET), which can be ascribed to the in situ formation of lightly branched PET. Further evidence of branched PET is provided via a dramatic increase in the rate of crystallization of the pulverized samples. These results suggest that SSSP processing can enhance the reuse and recyclability of PET. While SSSP processing has dramatic effects on the structure of polyesters and consequently their properties, a mild effect is observed for polyolefins. This thesis also demonstrates via a combination of methods that the well-exfoliated state can be achieved via SSSP processing of various polymer nanocomposites, using as-received, unmodified fillers. For example, extensive comparisons are made concerning the thermal stability in air or nitrogen atmosphere of polypropylene (PP)/clay, PP/graphite, and PP/carbon nanotube (CNT) nanocomposites made by SSSP. These comparisons suggest that the mechanism by which CNTs enhance the thermal stability of PP differs from the mechanism associated with clay and graphite.

  8. Pyrolysis of polyethylene terephthalate containing real waste plastics using Ni loaded zeolite catalysts

    NASA Astrophysics Data System (ADS)

    Al-asadi, M.; Miskolczi, N.

    2018-05-01

    In this work the pyrolysis of polyethylene terephthalate (PET) containing real waste plastic was investigated using different Ni loaded catalysts: Ni/ZSM-5, Ni/y-zeolite, Ni/β-zeolite and Ni/natural zeolite (clinoptilolite). Raw materials were pyrolyzed in a horizontal tubular reactor between 600 and 900°C using 10% of catalysts. It was found, that both temperature increasing and catalysts presence can increase the gas yields, however owing to gasification reactions, the pyrolysis oil yield decreased with increasing temperature. Ni/y-zeolite catalyst had the most benefit in gas yield increasing at low temperature; however Ni/ZSM-5 showed advanced property in gas yield increasing at high temperature. Gases contained hydrogen, carbon oxides and hydrocarbons, which composition was significantly affected by catalysts. Ni loaded zeolites favoured to the formation of hydrogen and branched hydrocarbons; furthermore the concentrations of both CO and CO2 were also increased as function of elevated temperature. That phenomenon was attributed to the further decomposition of PET, especially to the side chain scission reactions. Owing to the Boudouard reaction, the ratio of CO2/CO can increased with temperature. Pyrolysis oils were the mixtures of n-saturated, n-unsaturated, branched, oxygen free aromatics and oxygenated hydrocarbons. Temperature increasing has a significant effect to the aromatization and isomerization reactions, while the catalysts can efficiently decreased the concentration of oxygen containing compounds.

  9. Orientational fluctuations and phase transitions in 8CB confined by cylindrical pores of the PET film

    NASA Astrophysics Data System (ADS)

    Maksimochkin, G. I.; Shmeliova, D. V.; Pasechnik, S. V.; Dubtsov, A. V.; Semina, O. A.; Kralj, S.

    2016-08-01

    Results of optical investigations of the isotropic-nematic and nematic-smectic A phase transitions in porous polyethyleneterephthalate (PET) films filled with octyl-cyanobihenyl (8CB) liquid crystal (LC) are reported. Samples of porous films of thickness 23 µm with normally oriented cylindrical pores of a radius R ranging from 10 nm to 1000 nm were prepared using the track-etched membrane technology. The dynamic light scattering method was used to probe the nematic orientational fluctuations of confined LC samples. The corresponding relaxation time τ was measured as a function of R and temperature T at slow enough cooling rates (0.3-0.6 K/h) to locate the phase transition temperatures. Changes in τ(T) dependencies relatively sensitivity fingerprint the LC phase transformations. Experimental results are analysed using the Landau-de Gennes-Ginzburg phenomenological approach.

  10. Growth-climate relationships across topographic gradients in the northern Great Lakes

    USGS Publications Warehouse

    Dymond, S.F.; D'Amato, A.W.; Kolka, R.K.; Bolstad, P.V.; Sebestyen, S.D.; Bradford, John B.

    2016-01-01

    Climatic conditions exert important control over the growth, productivity, and distribution of forests, and characterizing these relationships is essential for understanding how forest ecosystems will respond to climate change. We used dendrochronological methods to develop climate–growth relationships for two dominant species, Populus tremuloides (quaking aspen) and Pinus resinosa (red pine), in the upper Great Lakes region to understand how climate and water availability influence annual forest productivity. Trees were sampled along a topographic gradient at the Marcell Experimental Forest (Minnesota, USA) to assess growth response to variations in temperature and different water availability metrics (precipitation, potential evapotranspiration (PET), cumulative moisture index (CMI), and soil water storage). Climatic variables were able to explain 33–58% of the variation in annual growth (as measured by ring-width increment) for quaking aspen and 37–74% of the variation for red pine. Climate–growth relationships were influenced by topography for quaking aspen but not for red pine. Annual ring growth for quaking aspen decreased with June CMI on ridges, decreased with temperature in the November prior to the growing season on sideslopes, and decreased with June PET on toeslopes. Red pine growth increased with increasing July PET across all topographic positions. These results indicate the sensitivity of both quaking aspen and red pine to local climate and show several vulnerabilities of these species to shifts in water supply and temperature because of climate change.

  11. Photoinduced electron transfer in an imidazolium ionic liquid and in its binary mixtures with water, methanol, and 2-propanol: appearance of Marcus-type of inversion.

    PubMed

    Sarkar, Souravi; Mandal, Sarthak; Ghatak, Chiranjib; Rao, Vishal Govind; Ghosh, Surajit; Sarkar, Nilmoni

    2012-02-02

    The photoinduced electron transfer (PET) reaction has been investigated in a room temperature imidazolium ionic liquid (RTIL), 1-ethyl-3-methylimidazolium ethyl sulfate ([Emim][EtSO(4)]) and also in [Emim][EtSO(4)]-co-solvents mixtures from N,N-dimethyl aniline (DMA) to different Coumarin dyes using steady state and time-resolved fluorescence quenching measurements. We have used water and methanol and 2-propanol as the cosolvents of RTILs for the PET study. On going from neat ionic liquid to the RTIL-co-solvents mixtures the electron transfer rate has been largely enhanced. In neat RTIL as well as in [Emim][EtSO(4)]-co-solvents mixtures, a Marcus type of inversion in the PET rate have been observed.

  12. Selective Separation of Metal Ions via Monolayer Nanoporous Graphene with Carboxyl Groups.

    PubMed

    Li, Zhan; Liu, Yanqi; Zhao, Yang; Zhang, Xin; Qian, Lijuan; Tian, Longlong; Bai, Jing; Qi, Wei; Yao, Huijun; Gao, Bin; Liu, Jie; Wu, Wangsuo; Qiu, Hongdeng

    2016-10-18

    Graphene-coated plastic substrates, such as polyethylene terephthalate (PET), are regularly used in flexible electronic devices. Here we demonstrate a new application of the graphene-coated nanoporous PET membrane for the selective separation of metal ions in an ion exchange manner. Irradiation with swift heavy ions is used to perforate graphene and PET substrate. This process could create graphene nanopores with carboxyl groups, thus forming conical holes in the PET after chemical etching to support graphene nanopores. Therefore, a monolayer nanoporous graphene membrane with a PET substrate is constructed successfully to investigate its ionic selective separation. We find that the permeation ratio of ions strongly depends on the temperature and H + concentration in the driving solution. An electric field can increase the permeation ratio of ions through the graphene nanopores, but it inhibits the ion selective separation. Moreover, the structure of the graphene nanopore with carboxyl groups is resolved at the density functional theory level. The results show the asymmetric structure of the nanopore with carboxyl groups, and the analysis indicates that the ionic permeation can be attributed to the ion exchange between metal ions and protons on the two sides of graphene nanopores. These results would be beneficial to the design of membrane separation materials made from graphene with efficient online and offline bulk separation.

  13. A phantom design and assessment of lesion detectability in PET imaging

    NASA Astrophysics Data System (ADS)

    Wollenweber, Scott D.; Kinahan, Paul E.; Alessio, Adam M.

    2017-03-01

    The early detection of abnormal regions with increased tracer uptake in positron emission tomography (PET) is a key driver of imaging system design and optimization as well as choice of imaging protocols. Detectability, however, remains difficult to assess due to the need for realistic objects mimicking the clinical scene, multiple lesion-present and lesion-absent images and multiple observers. Fillable phantoms, with tradeoffs between complexity and utility, provide a means to quantitatively test and compare imaging systems under truth-known conditions. These phantoms, however, often focus on quantification rather than detectability. This work presents extensions to a novel phantom design and analysis techniques to evaluate detectability in the context of realistic, non-piecewise constant backgrounds. The design consists of a phantom filled with small solid plastic balls and a radionuclide solution to mimic heterogeneous background uptake. A set of 3D-printed regular dodecahedral `features' were included at user-defined locations within the phantom to create `holes' within the matrix of chaotically-packed balls. These features fill at approximately 3:1 contrast to the lumpy background. A series of signal-known-present (SP) and signal-known-absent (SA) sub-images were generated and used as input for observer studies. This design was imaged in a head-like 20 cm diameter, 20 cm long cylinder and in a body-like 36 cm wide by 21 cm tall by 40 cm long tank. A series of model observer detectability indices were compared across scan conditions (count levels, number of scan replicates), PET image reconstruction methods (with/without TOF and PSF) and between PET/CT scanner system designs using the same phantom imaged on multiple systems. The detectability index was further compared to the noise-equivalent count (NEC) level to characterize the relationship between NEC and observer SNR.

  14. Use of O-15 water and C-11 butanol to measure cerebral blood flow (CBF) and water permeability with positron emission tomography (PET)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herscovitch, P.; Raichle, M.E.; Kilbourn, M.R.

    1985-05-01

    Tracers used to measure CBF with PET and the Kety autoradiographic approach should freely cross the blood-brain barrier. 0-15 water, which is not freely permeable, may underestimate CBF, especially at higher flows. The authors determined this under-estimation relative to flow measured with a freely diffusible tracer, C-11 butanol and used these data to calculate the extraction (E) and permeability surface area product (PS) for 0-15 water. Paired flow measurements were made with 0-15 water (CBF-wat) and C-11 butanol (CBF-but) in eight normal human subjects. Average CBF-but, 55.6 ml/(min . 100g) was significantly greater than CBF-water, 47.6 ml/(min . 100g). Themore » ratio of regional gray matter (GM) flow to white matter (WM) flow was significantly greater with C-11 butanol, indicating a greater underestimation of CBF with 0-15 water in the higher flow GM. Average E for water was 0.92 in WM and 0.82 in GM. The mean PS in GM, 148 ml/(min . 100g), was significantly greater than in WM, 94 ml/(min . 100g). Simulation studies demonstrated that a measurement error in CBF-wat or CBF-but causes an approximately equivalent error in E but a considerably larger error in PS due to the sensitivity of the equation, PS=-CBF . ln(1-E), to variations in E. Modest errors in E and PS result from tissue heterogeneity that occurs due to the limited spatial resolution of PET. The authors' measurements of E and PS for water are similar to data obtained by more invasive methods and demonstrate the ability of PET to measure brain water permeability.« less

  15. In vitro antioxidant activity of pet ether extract of black pepper

    PubMed Central

    Singh, Ramnik; Singh, Narinder; Saini, B.S.; Rao, Harwinder Singh

    2008-01-01

    Objective: To investigate the in vitro antioxidant activity of different fractions (R1, R2 and R3) obtained from pet ether extract of black pepper fruits (Piper nigrum Linn.) Materials and Methods: The fractions R1, R2 and R3 were eluted from pet ether and ethyl acetate in the ratio of 6:4, 5:5 and 4:6, respectively. 1,1-Diphenyl-2-picryl-hydrazyl (DPPH) radical, superoxide anion radical, nitric oxide radical, and hydroxyl radical scavenging assays were carried out to evaluate the antioxidant potential of the extract. Results: The free radical scavenging activity of the different fractions of pet ether extract of P. nigrum (PEPN) increased in a concentration dependent manner. The R3 and R2 fraction of PEPN in 500 µg/ml inhibited the peroxidation of a linoleic acid emulsion by 60.48±3.33% and 58.89±2.51%, respectively. In DPPH free radical scavenging assay, the activity of R3 and R2 were found to be almost similar. The R3 (100µg/ml) fraction of PEPN inhibited 55.68±4.48% nitric oxide radicals generated from sodium nitroprusside, whereas curcumin in the same concentration inhibited 84.27±4.12%. Moreover, PEPN scavenged the superoxide radical generated by the Xanthine/Xanthine oxidase system. The fraction R2 and R3 in the doses of 1000µg/ml inhibited 61.04±5.11% and 63.56±4.17%, respectively. The hydroxyl radical was generated by Fenton's reaction. The amounts of total phenolic compounds were determined and 56.98 µg pyrocatechol phenol equivalents were detected in one mg of R3. Conclusions: P. nigrum could be considered as a potential source of natural antioxidant. PMID:20040947

  16. A High Resolution Monolithic Crystal, DOI, MR Compatible, PET Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robert S Miyaoka

    The principle objective of this proposal is to develop a positron emission tomography (PET) detector with depth-of-interaction (DOI) positioning capability that will achieve state of the art spatial resolution and sensitivity performance for small animal PET imaging. When arranged in a ring or box detector geometry, the proposed detector module will support <1 mm3 image resolution and >15% absolute detection efficiency. The detector will also be compatible with operation in a MR scanner to support simultaneous multi-modality imaging. The detector design will utilize a thick, monolithic crystal scintillator readout by a two-dimensional array of silicon photomultiplier (SiPM) devices using amore » novel sensor on the entrance surface (SES) design. Our hypothesis is that our single-ended readout SES design will provide an effective DOI positioning performance equivalent to more expensive dual-ended readout techniques and at a significantly lower cost. Our monolithic crystal design will also lead to a significantly lower cost system. It is our goal to design a detector with state of the art performance but at a price point that is affordable so the technology can be disseminated to many laboratories. A second hypothesis is that using SiPM arrays, the detector will be able to operate in a MR scanner without any degradation in performance to support simultaneous PET/MR imaging. Having a co-registered MR image will assist in radiotracer localization and may also be used for partial volume corrections to improve radiotracer uptake quantitation. The far reaching goal of this research is to develop technology for medical research that will lead to improvements in human health care.« less

  17. Research on the time-temperature-damage superposition principle of NEPE propellant

    NASA Astrophysics Data System (ADS)

    Han, Long; Chen, Xiong; Xu, Jin-sheng; Zhou, Chang-sheng; Yu, Jia-quan

    2015-11-01

    To describe the relaxation behavior of NEPE (Nitrate Ester Plasticized Polyether) propellant, we analyzed the equivalent relationships between time, temperature, and damage. We conducted a series of uniaxial tensile tests and employed a cumulative damage model to calculate the damage values for relaxation tests at different strain levels. The damage evolution curve of the tensile test at 100 mm/min was obtained through numerical analysis. Relaxation tests were conducted over a range of temperature and strain levels, and the equivalent relationship between time, temperature, and damage was deduced based on free volume theory. The equivalent relationship was then used to generate predictions of the long-term relaxation behavior of the NEPE propellant. Subsequently, the equivalent relationship between time and damage was introduced into the linear viscoelastic model to establish a nonlinear model which is capable of describing the mechanical behavior of composite propellants under a uniaxial tensile load. The comparison between model prediction and experimental data shows that the presented model provides a reliable forecast of the mechanical behavior of propellants.

  18. A multiplexed TOF and DOI capable PET detector using a binary position sensitive network.

    PubMed

    Bieniosek, M F; Cates, J W; Levin, C S

    2016-11-07

    Time of flight (TOF) and depth of interaction (DOI) capabilities can significantly enhance the quality and uniformity of positron emission tomography (PET) images. Many proposed TOF/DOI PET detectors require complex readout systems using additional photosensors, active cooling, or waveform sampling. This work describes a high performance, low complexity, room temperature TOF/DOI PET module. The module uses multiplexed timing channels to significantly reduce the electronic readout complexity of the PET detector while maintaining excellent timing, energy, and position resolution. DOI was determined using a two layer light sharing scintillation crystal array with a novel binary position sensitive network. A 20 mm effective thickness LYSO crystal array with four 3 mm  ×  3 mm silicon photomultipliers (SiPM) read out by a single timing channel, one energy channel and two position channels achieved a full width half maximum (FWHM) coincidence time resolution of 180  ±  2 ps with 10 mm of DOI resolution and 11% energy resolution. With sixteen 3 mm  ×  3 mm SiPMs read out by a single timing channel, one energy channel and four position channels a coincidence time resolution 204  ±  1 ps was achieved with 10 mm of DOI resolution and 15% energy resolution. The methods presented here could significantly simplify the construction of high performance TOF/DOI PET detectors.

  19. Passive activity observation (PAO) method to estimate outdoor thermal adaptation in public space: case studies in Australian cities.

    PubMed

    Sharifi, Ehsan; Boland, John

    2018-06-18

    Outdoor thermal comfort is influenced by people's climate expectations, perceptions and adaptation capacity. Varied individual response to comfortable or stressful thermal environments results in a deviation between actual outdoor thermal activity choices and those predicted by thermal comfort indices. This paper presents a passive activity observation (PAO) method for estimating contextual limits of outdoor thermal adaptation. The PAO method determines which thermal environment result in statistically meaningful changes may occur in outdoor activity patterns, and it estimates thresholds of outdoor thermal neutrality and limits of thermal adaptation in public space based on activity observation and microclimate field measurement. Applications of the PAO method have been demonstrated in Adelaide, Melbourne and Sydney, where outdoor activities were analysed against outdoor thermal comfort indices between 2013 and 2014. Adjusted apparent temperature (aAT), adaptive predicted mean vote (aPMV), outdoor standard effective temperature (OUT_SET), physiological equivalent temperature (PET) and universal thermal comfort index (UTCI) are calculated from the PAO data. Using the PAO method, the high threshold of outdoor thermal neutrality was observed between 24 °C for optional activities and 34 °C for necessary activities (UTCI scale). Meanwhile, the ultimate limit of thermal adaptation in uncontrolled public spaces is estimated to be between 28 °C for social activities and 48 °C for necessary activities. Normalised results indicate that city-wide high thresholds for outdoor thermal neutrality vary from 25 °C in Melbourne to 26 °C in Sydney and 30 °C in Adelaide. The PAO method is a relatively fast and localised method for measuring limits of outdoor thermal adaptation and effectively informs urban design and policy making in the context of climate change.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guney, Ali; Poyraz, M. Ibrahim; Kangal, Olgac, E-mail: kangal@itu.edu.tr

    Highlights: • Both PET and PVC have nearly the same densities. • The best pH value will be 4 for optimizing pH values. • Malic acid gave the best results for selective separation of PET and PVC. - Abstract: Plastics have become the widely used materials because of their advantages, such as cheapness, endurance, lightness, and hygiene. However, they cause waste and soil pollution and they do not easily decompose. Many promising technologies are being investigated for separating mixed thermoplastics, but they are still uneconomical and unreliable. Depending on their surface characteristics, these plastics can be separated from each othermore » by flotation method which is useful mineral processing technique with its low cost and simplicity. The main objective of this study is to investigate the flotation characteristics of PET and PVC and determine the effect of plasticizer reagents on efficient plastic separation. For that purpose, various parameters such as pH, plasticizer concentration, plasticizer type, conditioning temperature and thermal conditioning were investigated. As a result, PET particles were floated with 95.1% purity and 65.3% efficiency while PVC particles were obtained with 98.1% purity and 65.3% efficiency.« less

  1. Electroless plating Cu-Co-P polyalloy on UV/ozonolysis irradiated polyethylene terephthalate film and its corrosion resistance

    NASA Astrophysics Data System (ADS)

    Hou, Lei; Bi, Siyi; Zhao, Hang; Xu, Yumeng; Mu, Yuhang; Lu, Yinxiang

    2017-05-01

    High corrosion resistant Cu-Co-P coatings were firstly prepared on polyethylene terephthalate (PET) substrate by electroless plating in combination with UV/ozonolysis irradiation under optimized cobalt sulfate heptahydrate concentration, pH value, plating temperature and time. The copper polyalloy/PET composite can be obtained in three steps, namely: (i) the generation of oxygen-containing functionalities (carboxylic groups) onto PET surface through UV irradiation combined with ozone, (ii) Cu seeding catalysts were obtained after being immersed into cupric citrate and NaBH4 solutions subsequently, and (iii) Cu-Co-P polyalloy metallization using electroless plating bath. Attenuated total reflection fourier transformation infrared spectrometer (ATR-FTIR), X-ray photoelectron spectroscopy (XPS), water contact angle measurement and energy dispersive X-ray analysis (EDAX) were utilized to track the surface changes during the whole process. The electroless plating conditions were optimized by an orthogonal experiment (L9(3)4) for Cu-Co-P coating as follows: CoSO4·7H2O addition of 0.08 M, pH value, plating temperature and time were set on 10.0, 35 °C and 25 min, respectively. Under the optimal conditions, copper polyalloy possessed high adhesive strength and the lowest surface resistance (8.06 Ω/sq), while maintaining reliability even after over 1000 times of bending and mechanical stress. The results of scanning electron microscope (SEM) and atomic force microscope (AFM) measurements showed that Cu-Co-P layer formed on PET surface was imparted with fine uniformity and high compactness. Electrochemical test revealed the optimized Cu-Co-P coatings exhibited high corrosion resistance in NaCl, NaOH and HCl solutions, respectively. The excellent electromagnetic interference shielding effectiveness (EMI SE >99.999% at frequency ranging from 30 MHz to 1000 MHz) of copper polyalloy/PET composites was confirmed by the spectrum analyzer. Therefore, this copper polyalloy will have potential applications in microelectronics packaging and coatings for anti-corrosion and electromagnetic interference shielding.

  2. TH-CD-202-05: DECT Based Tissue Segmentation as Input to Monte Carlo Simulations for Proton Treatment Verification Using PET Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berndt, B; Wuerl, M; Dedes, G

    Purpose: To improve agreement of predicted and measured positron emitter yields in patients, after proton irradiation for PET-based treatment verification, using a novel dual energy CT (DECT) tissue segmentation approach, overcoming known deficiencies from single energy CT (SECT). Methods: DECT head scans of 5 trauma patients were segmented and compared to existing decomposition methods with a first focus on the brain. For validation purposes, three brain equivalent solutions [water, white matter (WM) and grey matter (GM) – equivalent with respect to their reference carbon and oxygen contents and CT numbers at 90kVp and 150kVp] were prepared from water, ethanol, sucrosemore » and salt. The activities of all brain solutions, measured during a PET scan after uniform proton irradiation, were compared to Monte Carlo simulations. Simulation inputs were various solution compositions obtained from different segmentation approaches from DECT, SECT scans, and known reference composition. Virtual GM solution salt concentration corrections were applied based on DECT measurements of solutions with varying salt concentration. Results: The novel tissue segmentation showed qualitative improvements in %C for patient brain scans (ground truth unavailable). The activity simulations based on reference solution compositions agree with the measurement within 3–5% (4–8Bq/ml). These reference simulations showed an absolute activity difference between WM (20%C) and GM (10%C) to H2O (0%C) of 43 Bq/ml and 22 Bq/ml, respectively. Activity differences between reference simulations and segmented ones varied from −6 to 1 Bq/ml for DECT and −79 to 8 Bq/ml for SECT. Conclusion: Compared to the conventionally used SECT segmentation, the DECT based segmentation indicates a qualitative and quantitative improvement. In controlled solutions, a MC input based on DECT segmentation leads to better agreement with the reference. Future work will address the anticipated improvement of quantification accuracy in patients, comparing different tissue decomposition methods with an MR brain segmentation. Acknowledgement: DFG-MAP and HIT-Heidelberg Deutsche Forschungsgemeinschaft (MAP); Bundesministerium fur Bildung und Forschung (01IB13001)« less

  3. Exploring the linkage between drought, high temperatures, and hydrologic sensitivities: A case study of the 2012 Great Plains drought.

    NASA Astrophysics Data System (ADS)

    Livneh, B.; Hoerling, M. P.

    2014-12-01

    The occurrence of drought is associated with agricultural loss, water supply shortfalls, and other economic impacts. Here we explore the physical relationships between precipitation deficits, high temperatures, and hydrologic responses as a pathway to better anticipate drought impacts. Current methodologies to predict hydrologic scarcity include local monitoring of river flows, remote sensing of land-surface wetness, drought indices, expert judgment, climate indices (e.g. SST-relationships) and the application of hydrologic models. At longer lead times, predictions of drought have most frequently been made on the basis of GCM ensembles, with subsequent downscaling of those to scales over which hydrologic predictions can be made. This study focuses on two important aspects of drought. First, we explore the causal hydro-climatic timeline of a drought event, namely (a) the lack of precipitation, which serves to reduce soil moisture and produce (b) a skewed Bowen ratio, i.e. comparatively more sensible heating (warming) with less ET, resulting in (c) anomalously warm conditions. We seek to assess the extent to which the lack of precipitation contributes to warming temperatures, and the further effects of that warming on hydrology and the severity of drought impacts. An ensemble of GCM simulations will be used to explore the evolution of the land surface energy budget during a recent Great Plains drought event, which will subsequently be used to drive a hydrologic model. Second, we examine the impacts of the critical assumptions relating climatic variables with water demand, specifically the relationship between potential evapotranspiration (PET) and temperature. The common oversimplification in relating PET to temperature is explored against a more physically consistent energy balance estimate of PET, using the Penman-Monteith approach and the hydrologic impacts are presented. Results from this work are anticipated to have broad relevance for future water management and planning, to better characterize drought impacts.

  4. Hawking radiation, Unruh radiation, and the equivalence principle.

    PubMed

    Singleton, Douglas; Wilburn, Steve

    2011-08-19

    We compare the response function of an Unruh-DeWitt detector for different space-times and different vacua and show that there is a detailed violation of the equivalence principle. In particular comparing the response of an accelerating detector to a detector at rest in a Schwarzschild space-time we find that both detectors register thermal radiation, but for a given, equivalent acceleration the fixed detector in the Schwarzschild space-time measures a higher temperature. This allows one to locally distinguish the two cases. As one approaches the horizon the two temperatures have the same limit so that the equivalence principle is restored at the horizon. © 2011 American Physical Society

  5. Comparison of Visual and Quantitative Florbetapir F 18 Positron Emission Tomography Analysis in Predicting Mild Cognitive Impairment Outcomes.

    PubMed

    Schreiber, Stefanie; Landau, Susan M; Fero, Allison; Schreiber, Frank; Jagust, William J

    2015-10-01

    The applicability of β-amyloid peptide (Aβ) positron emission tomography (PET) as a biomarker in clinical settings to aid in selection of individuals at preclinical and prodromal Alzheimer disease (AD) will depend on the practicality of PET image analysis. In this context, visual-based Aβ PET assessment seems to be the most feasible approach. To determine the agreement between visual and quantitative Aβ PET analysis and to assess the ability of both techniques to predict conversion from mild cognitive impairment (MCI) to AD. A longitudinal study was conducted among the Alzheimer's Disease Neuroimaging Initiative (ADNI) sites in the United States and Canada during a 1.6-year mean follow-up period. The study was performed from September 21, 2010, to August 11, 2014; data analysis was conducted from September 21, 2014, to May 26, 2015. Participants included 401 individuals with MCI receiving care at a specialty clinic (219 [54.6%] men; mean [SD] age, 71.6 [7.5] years; 16.2 [2.7] years of education). All participants were studied with florbetapir F 18 [18F] PET. The standardized uptake value ratio (SUVR) positivity threshold was 1.11, and one reader rated all images, with a subset of 125 scans rated by a second reader. Sensitivity and specificity of positive and negative [18F] florbetapir PET categorization, which was estimated with cerebrospinal fluid Aβ1-42 as the reference standard. Risk for conversion to AD was assessed using Cox proportional hazards regression models. The frequency of Aβ positivity was 48.9% (196 patients; visual analysis), 55.1% (221 patients; SUVR), and 64.8% (166 patients; cerebrospinal fluid), yielding substantial agreement between visual and SUVR data (κ = 0.74) and between all methods (Fleiss κ = 0.71). For approximately 10% of the 401 participants in whom visual and SUVR data disagreed, interrater reliability was moderate (κ = 0.44), but it was very high if visual and quantitative results agreed (κ = 0.92). Visual analysis had a lower sensitivity (79% vs 85%) but higher specificity (96% vs 90%), respectively, compared with SUVR. The conversion rate was 15.2% within a mean of 1.6 years, and a positive [18F] florbetapir baseline scan was associated with a 6.91-fold (SUVR) or 11.38-fold (visual) greater hazard for AD conversion, which changed only modestly after covariate adjustment for apolipoprotein ε4, concurrent fludeoxyglucose F 18 PET scan, and baseline cognitive status. Visual and SUVR Aβ PET analysis may be equivalently used to determine Aβ status for individuals with MCI participating in clinical trials, and both approaches add significant value for clinical course prognostication.

  6. Recovery and normalization of triple coincidences in PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lage, Eduardo, E-mail: elage@mit.edu; Parot, Vicente; Dave, Shivang R.

    2015-03-15

    Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose amore » simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with the authors’ method increased peak NEC rates of the scanner by 26.6% and 32% for mouse- and rat-sized objects, respectively. This increase in NEC-rate performance was also reflected in the image-quality metrics. Images reconstructed using double and triple coincidences recovered using their method had better signal-to-noise ratio than those obtained using only double coincidences, while preserving spatial resolution and contrast. Distribution of triple coincidences using an equal-weighting scheme increased apparent system sensitivity but degraded image quality. The performance boost provided by the inclusion of triple coincidences using their method allowed to reduce the acquisition time of standard imaging procedures by up to ∼25%. Conclusions: Recovering triple coincidences with the proposed method can effectively increase the sensitivity of current clinical and preclinical PET systems without compromising other parameters like spatial resolution or contrast.« less

  7. Replacing climatological potential evapotranspiration estimates with dynamic satellite-based observations in operational hydrologic prediction models

    NASA Astrophysics Data System (ADS)

    Franz, K. J.; Bowman, A. L.; Hogue, T. S.; Kim, J.; Spies, R.

    2011-12-01

    In the face of a changing climate, growing populations, and increased human habitation in hydrologically risky locations, both short- and long-range planners increasingly require robust and reliable streamflow forecast information. Current operational forecasting utilizes watershed-scale, conceptual models driven by ground-based (commonly point-scale) observations of precipitation and temperature and climatological potential evapotranspiration (PET) estimates. The PET values are derived from historic pan evaporation observations and remain static from year-to-year. The need for regional dynamic PET values is vital for improved operational forecasting. With the advent of satellite remote sensing and the adoption of a more flexible operational forecast system by the National Weather Service, incorporation of advanced data products is now more feasible than in years past. In this study, we will test a previously developed satellite-derived PET product (UCLA MODIS-PET) in the National Weather Service forecast models and compare the model results to current methods. The UCLA MODIS-PET method is based on the Priestley-Taylor formulation, is driven with MODIS satellite products, and produces a daily, 250m PET estimate. The focus area is eight headwater basins in the upper Midwest U.S. There is a need to develop improved forecasting methods for this region that are able to account for climatic and landscape changes more readily and effectively than current methods. This region is highly flood prone yet sensitive to prolonged dry periods in late summer and early fall, and is characterized by a highly managed landscape, which has drastically altered the natural hydrologic cycle. Our goal is to improve model simulations, and thereby, the initial conditions prior to the start of a forecast through the use of PET values that better reflect actual watershed conditions. The forecast models are being tested in both distributed and lumped mode.

  8. Compositional and Mechanical Properties of Peanuts Roasted to Equivalent Colors using Different Time/Temperature Combinations

    USDA-ARS?s Scientific Manuscript database

    Peanuts in North America and Europe are primarily consumed after dry roasting. Standard industry practice is to roast peanuts to a specific surface color (Hunter L-value) for a given application; however, equivalent surface colors can be attained using different roast temperature/time combinations,...

  9. Demonstration of a Bias Tunable Quantum Dots-in-a-Well Focal Plane Array

    DTIC Science & Technology

    2009-01-01

    uniformity and mea- sured noise equivalent temperature difference for the double DWELL devices is computed and compared to the same results from the original...first generation DWELL. Finally, higher temperature operation is explored. Overall, the double DWELL devices had lower noise equivalent temperature...infrared photodetectors ( QWIPs ) with various doping and impurities have produced FPAs capable of detection across much of the infrared spectrum from

  10. Night Vision Laboratory Static Performance Model for Thermal Viewing Systems

    DTIC Science & Technology

    1975-04-01

    Research and Development Technical Report f ECOM-� • i’.__1’=• =•NIGHT VISION LABORATORY STATIC PERFORMANCE MODEL 1 S1=• : FOR THERMAL VIEWING...resolvable temperature Infrared imaging Minimum detectable temperature1.Detection and recognition performance Night visi,-)n Noise equivalent temperature...modulation transfer function (MTF). The noise charactcristics are specified by the noise equivalent temper- ature difference (NE AT), The next sections

  11. From dead leaves to sustainable organic resistive switching memory.

    PubMed

    Sun, Bai; Zhu, Shouhui; Mao, Shuangsuo; Zheng, Pingping; Xia, Yudong; Yang, Feng; Lei, Ming; Zhao, Yong

    2018-03-01

    An environmental-friendly, sustainable, pollution-free, biodegradable, flexible and wearable electronic device hold advanced potential applications. Here, an organic resistive switching memory device with Ag/Leaves/Ti/PET structure on a flexible polyethylene terephthalate (PET) substrate was fabricated for the first time. We observed an obvious resistive switching memory characteristic with large switching resistance ratio and stable cycle performance at room temperature. This work demonstrates that leaves, a useless waste, can be properly treated to make useful devices. Furthermore, the as-fabricated devices can be degraded naturally without damage to the environment. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. An experimental study of the autoignition characteristics of conventional jet fuel/oxidizer mixtures: Jet-A and JP-8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Kamal; Sung, Chih-Jen

    2010-04-15

    Ignition delay times of Jet-A/oxidizer and JP-8/oxidizer mixtures are measured using a heated rapid compression machine at compressed charge pressures corresponding to 7, 15, and 30 bar, compressed temperatures ranging from 650 to 1100 K, and equivalence ratios varying from 0.42 to 2.26. When using air as the oxidant, two oxidizer-to-fuel mass ratios of 13 and 19 are investigated. To achieve higher compressed temperatures for fuel lean mixtures (equivalence ratio of {proportional_to}0.42), argon dilution is also used and the corresponding oxidizer-to-fuel mass ratio is 84.9. For the conditions studied, experimental results show two-stage ignition characteristics for both Jet-A and JP-8.more » Variations of both the first-stage and overall ignition delays with compressed temperature, compressed pressure, and equivalence ratio are reported and correlated. It is noted that the negative temperature coefficient phenomenon becomes more prominent at relatively lower pressures. Furthermore, the first-stage-ignition delay is found to be less sensitive to changes in equivalence ratio and primarily dependent on temperature. (author)« less

  13. Robust, Self-Healing Superhydrophobic Fabrics Prepared by One-Step Coating of PDMS and Octadecylamine

    PubMed Central

    Xue, Chao-Hua; Bai, Xue; Jia, Shun-Tian

    2016-01-01

    A robust, self-healing superhydrophobic poly(ethylene terephthalate) (PET) fabric was fabricated by a convenient solution-dipping method using an easily available material system consisting of polydimethylsiloxane and octadecylamine (ODA). The surface roughness was formed by self-roughening of ODA coating on PET fibers without any lithography steps or adding any nanomaterials. The fabric coating was durable to withstand 120 cycles of laundry and 5000 cycles of abrasion without apparently changing the superhydrophobicity. More interestingly, the fabric can restore its super liquid-repellent property by 72 h at room temperature even after 20000 cycles of abrasion. Meanwhile, after being damaged chemically, the fabric can restore its superhydrophobicity automatically in 12 h at room temperature or by a short-time heating treatment. We envision that this simple but effective coating system may lead to the development of robust protective clothing for various applications. PMID:27264995

  14. Depolymerization of Trityl End-Capped Poly(Ethyl Glyoxylate): Potential Applications in Smart Packaging.

    PubMed

    Fan, Bo; Salazar, Rómulo; Gillies, Elizabeth R

    2018-06-01

    The temperature-dependent depolymerization of self-immolative poly(ethyl glyoxylate) (PEtG) capped with triphenylmethyl (trityl) groups is studied and its potential application for smart packaging is explored. PEtGs with four different trityl end-caps are prepared and found to undergo depolymerization to volatile products from the solid state at different rates depending on temperature and the electron-donating substituents on the trityl aromatic rings. Through the incorporation of hydrophobic dyes including Nile red and IR-780, the depolymerization is visualized as a color change of the dye as it changes from a dispersed to aggregated state. The ability of this platform to provide information on thermal history through an easily readable signal makes it promising in smart packaging applications for sensitive products such a food and other cargo that is susceptible to degradation. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. PET-modified red mud as catalysts for oxidative desulfurization reactions.

    PubMed

    do Prado, Nayara T; Heitmann, Ana P; Mansur, Herman S; Mansur, Alexandra A; Oliveira, Luiz C A; de Castro, Cinthia S

    2017-07-01

    This work describes the synthesis of catalysts based on red mud/polyethylene terephthalate (PET) composites and their subsequent heat treatment under N 2 atmosphere. The materials were characterized by scanning electron microscopy (SEM), temperature programmed reduction (TPR), Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), thermogravimetric (TG) analysis and N 2 adsorption/desorption. The catalysts were evaluated in the oxidative desulfurization reaction of dibenzothiophene (DBT) in a biphasic system. The results indicated that the PET impregnation on red mud increased the affinity of the catalyst with the nonpolar phase (fuel), in which the contaminant was dissolved, allowing a higher conversion (up to 80%) and selectivity to the corresponding dibenzothiophene sulfone. The sulfone compound is more polar than DBT and diffused into the polar solvent as indicated by the data obtained via gas chromatography-mass spectrometry (GC-MS). Copyright © 2017. Published by Elsevier B.V.

  16. High performance ZnO:Al films deposited on PET substrates using facing target sputtering

    NASA Astrophysics Data System (ADS)

    Guo, Tingting; Dong, Guobo; Gao, Fangyuan; Xiao, Yu; Chen, Qiang; Diao, Xungang

    2013-10-01

    ZnO:Al (ZAO) thin films have been deposited on flexible PET substrates using a plasma damage-free facing target sputtering system at room temperature. The structure, surface morphology, electrical and optical properties were investigated as a function of working power. All the samples have a highly preferred orientation of the c-axis perpendicular to the PET substrate and have a high quality surface. With increased working power, the carrier concentration changes slightly, the mobility increases at the beginning and decreases after it reaches a maximum value, in line with electrical conductivity. The figure of merit has been significantly improved with increasing of the working power. Under the optimized condition, the lowest resistivity of 1.3 × 10-3 Ω cm with a sheet resistance of 29 Ω/□ and the relative visible transmittance above 93% in the visible region were obtained.

  17. Increasing Northern Hemisphere water deficit

    USGS Publications Warehouse

    McCabe, Gregory J.; Wolock, David M.

    2015-01-01

    A monthly water-balance model is used with CRUTS3.1 gridded monthly precipitation and potential evapotranspiration (PET) data to examine changes in global water deficit (PET minus actual evapotranspiration) for the Northern Hemisphere (NH) for the years 1905 through 2009. Results show that NH deficit increased dramatically near the year 2000 during both the cool (October through March) and warm (April through September) seasons. The increase in water deficit near 2000 coincides with a substantial increase in NH temperature and PET. The most pronounced increases in deficit occurred for the latitudinal band from 0 to 40°N. These results indicate that global warming has increased the water deficit in the NH and that the increase since 2000 is unprecedented for the 1905 through 2009 period. Additionally, coincident with the increase in deficit near 2000, mean NH runoff also increased due to increases in P. We explain the apparent contradiction of concurrent increases in deficit and increases in runoff.

  18. Natural-Synthetic Hybrid Polymers Developed via Electrospinning: The Effect of PET in Chitosan/Starch System

    PubMed Central

    Espíndola-González, Adolfo; Martínez-Hernández, Ana Laura; Fernández-Escobar, Francisco; Castaño, Victor Manuel; Brostow, Witold; Datashvili, Tea; Velasco-Santos, Carlos

    2011-01-01

    Chitosan is an amino polysaccharide found in nature, which is biodegradable, nontoxic and biocompatible. It has versatile features and can be used in a variety of applications including films, packaging, and also in medical surgery. Recently a possibility to diversify chitosan properties has emerged by combining it with synthetic materials to produce novel natural-synthetic hybrid polymers. We have studied structural and thermophysical properties of chitosan + starch + poly(ethylene terephthalate) (Ch + S + PET) fibers developed via electrospinning. Properties of these hybrids polymers are compared with extant chitosan containing hybrids synthesized by electrospinning. Molecular interactions and orientation in the fibers are analyzed by infrared and Raman spectroscopies respectively, morphology by scanning electron microscopy and thermophysical properties by thermogravimetric analysis and differential scanning calorimetry. Addition of PET to Ch + S systems results in improved thermal stability at elevated temperatures. PMID:21673930

  19. Teaching Air Pollution in an Authentic Context

    NASA Astrophysics Data System (ADS)

    Mandrikas, Achilleas; Stavrou, Dimitrios; Skordoulis, Constantine

    2017-04-01

    This paper describes a teaching-learning sequence (TLS) about air pollution and the findings resulting from its implementation by pre-service elementary teachers (PET) currently undergraduate students of the Department of Primary Education in the National and Kapodistrian University of Athens, Greece. The TLS focused on the relation of air pollution with wind and topography in local conditions. An authentic context was provided to the students based on daily up-to-date meteorological data via the Internet in order to estimate air pollution. The results are encouraging given that PET can correlate wind and concentration of air pollutants through reading specialized angular diagrams and weather maps, can recognize the correlation of topography in the concentration of air pollutants, and can describe temperature inversion. However, the PET demonstrated clear difficulties in ability of orientation, in wind naming, and in interpretation of symbols on weather map. Finally, the implications on teaching air pollution are discussed.

  20. Projecting the potential evapotranspiration by coupling different formulations and input data reliabilities: The possible uncertainty source for climate change impacts on hydrological regime

    NASA Astrophysics Data System (ADS)

    Wang, Weiguang; Li, Changni; Xing, Wanqiu; Fu, Jianyu

    2017-12-01

    Representing atmospheric evaporating capability for a hypothetical reference surface, potential evapotranspiration (PET) determines the upper limit of actual evapotranspiration and is an important input to hydrological models. Due that present climate models do not give direct estimates of PET when simulating the hydrological response to future climate change, the PET must be estimated first and is subject to the uncertainty on account of many existing formulae and different input data reliabilities. Using four different PET estimation approaches, i.e., the more physically Penman (PN) equation with less reliable input variables, more empirical radiation-based Priestley-Taylor (PT) equation with relatively dependable downscaled data, the most simply temperature-based Hamon (HM) equation with the most reliable downscaled variable, and downscaling PET directly by the statistical downscaling model, this paper investigated the differences of runoff projection caused by the alternative PET methods by a well calibrated abcd monthly hydrological model. Three catchments, i.e., the Luanhe River Basin, the Source Region of the Yellow River and the Ganjiang River Basin, representing a large climatic diversity were chosen as examples to illustrate this issue. The results indicated that although similar monthly patterns of PET over the period 2021-2050 for each catchment were provided by the four methods, the magnitudes of PET were still slightly different, especially for spring and summer months in the Luanhe River Basin and the Source Region of the Yellow River with relatively dry climate feature. The apparent discrepancy in magnitude of change in future runoff and even the diverse change direction for summer months in the Luanhe River Basin and spring months in the Source Region of the Yellow River indicated that the PET method related uncertainty occurred, especially in the Luanhe River Basin and the Source Region of the Yellow River with smaller aridity index. Moreover, the possible reason of discrepancies in uncertainty between three catchments was quantitatively discussed by the contribution analysis based on climatic elasticity method. This study can provide beneficial reference to comprehensively understand the impacts of climate change on hydrological regime and thus improve the regional strategy for future water resource management.

  1. Advanced-stage Hodgkin lymphoma: US/chest radiography for detection of relapse in patients in first complete remission--a randomized trial of routine surveillance imaging procedures.

    PubMed

    Picardi, Marco; Pugliese, Novella; Cirillo, Michele; Zeppa, Pio; Cozzolino, Imma; Ciancia, Giuseppe; Pettinato, Guido; Salvatore, Claudia; Quintarelli, Concetta; Pane, Fabrizio

    2014-07-01

    To compare the use of fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) with the use of a combination of ultrasonography (US) and chest radiography for systematic follow-up of patients with high-risk Hodgkin lymphoma. Institutional review board approval and informed consent were obtained. In a single center between January 2001 and December 2009, patients with advanced-stage Hodgkin lymphoma who had responded completely to first-line treatment were randomly assigned (1:1) to follow-up with either PET/CT or US/chest radiography. Follow-up included clinical and imaging procedures at 4, 8, 12, 16, 20, 24, 30, 36, 48, 60, 84, and 108 months after treatment discontinuation. When clinical and/or imaging results were positive, recurrence was confirmed histologically. The primary endpoint was to compare the sensitivity of the two follow-up imaging approaches. Secondary endpoints were their specificity, positive and negative predictive values, time to recurrence detection, radiation risks, and costs. A total of 300 patients were randomized into the two arms. The study was closed after a median follow-up time of 60 months, with a relapse rate of 27%. Sensitivity for detection of Hodgkin lymphoma was similar for the two follow-up approaches. All of the relapses (40 of 40) were identified with FDG PET/CT (100%) and 39 of 40 relapses were identified with US/chest radiography (97.5%; P = .0001 for the equivalence test). US/chest radiography showed significantly higher specificity and positive predictive value than did PET/CT (96% [106 of 110] vs 86% [95 of 110], respectively; P = .02; and 91% [39 of 43] vs 73% [40 of 55], respectively; P = .01). Exposure to ionizing radiation was estimated to be 14.5 mSv for one PET/CT examination versus 0.1 mSv for one chest radiographic examination. Estimated cost per relapse diagnosed with routine PET/CT was 10-fold higher compared with that diagnosed with routine US/chest radiography. US and chest radiography are diagnostic tools that enable effective, safe, and low-cost routine surveillance imaging for patients at high risk of Hodgkin lymphoma relapse. © RSNA, 2014.

  2. Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm.

    PubMed

    Ahmadian, Alireza; Ay, Mohammad R; Bidgoli, Javad H; Sarkar, Saeed; Zaidi, Habib

    2008-10-01

    Oral contrast is usually administered in most X-ray computed tomography (CT) examinations of the abdomen and the pelvis as it allows more accurate identification of the bowel and facilitates the interpretation of abdominal and pelvic CT studies. However, the misclassification of contrast medium with high-density bone in CT-based attenuation correction (CTAC) is known to generate artifacts in the attenuation map (mumap), thus resulting in overcorrection for attenuation of positron emission tomography (PET) images. In this study, we developed an automated algorithm for segmentation and classification of regions containing oral contrast medium to correct for artifacts in CT-attenuation-corrected PET images using the segmented contrast correction (SCC) algorithm. The proposed algorithm consists of two steps: first, high CT number object segmentation using combined region- and boundary-based segmentation and second, object classification to bone and contrast agent using a knowledge-based nonlinear fuzzy classifier. Thereafter, the CT numbers of pixels belonging to the region classified as contrast medium are substituted with their equivalent effective bone CT numbers using the SCC algorithm. The generated CT images are then down-sampled followed by Gaussian smoothing to match the resolution of PET images. A piecewise calibration curve was then used to convert CT pixel values to linear attenuation coefficients at 511 keV. The visual assessment of segmented regions performed by an experienced radiologist confirmed the accuracy of the segmentation and classification algorithms for delineation of contrast-enhanced regions in clinical CT images. The quantitative analysis of generated mumaps of 21 clinical CT colonoscopy datasets showed an overestimation ranging between 24.4% and 37.3% in the 3D-classified regions depending on their volume and the concentration of contrast medium. Two PET/CT studies known to be problematic demonstrated the applicability of the technique in clinical setting. More importantly, correction of oral contrast artifacts improved the readability and interpretation of the PET scan and showed substantial decrease of the SUV (104.3%) after correction. An automated segmentation algorithm for classification of irregular shapes of regions containing contrast medium was developed for wider applicability of the SCC algorithm for correction of oral contrast artifacts during the CTAC procedure. The algorithm is being refined and further validated in clinical setting.

  3. Engineering and performance (NEMA and animal) of a lower-cost higher-resolution animal PET/CT scanner using photomultiplier-quadrant-sharing detectors.

    PubMed

    Wong, Wai-Hoi; Li, Hongdi; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio A; Liu, Shitao; Wang, Chao; An, Shaohui

    2012-11-01

    The dedicated murine PET (MuPET) scanner is a high-resolution, high-sensitivity, and low-cost preclinical PET camera designed and manufactured at our laboratory. In this article, we report its performance according to the NU 4-2008 standards of the National Electrical Manufacturers Association (NEMA). We also report the results of additional phantom and mouse studies. The MuPET scanner, which is integrated with a CT camera, is based on the photomultiplier-quadrant-sharing concept and comprises 180 blocks of 13 × 13 lutetium yttrium oxyorthosilicate crystals (1.24 × 1.4 × 9.5 mm(3)) and 210 low-cost 19-mm photomultipliers. The camera has 78 detector rings, with an 11.6-cm axial field of view and a ring diameter of 16.6 cm. We measured the energy resolution, scatter fraction, sensitivity, spatial resolution, and counting rate performance of the scanner. In addition, we scanned the NEMA image-quality phantom, Micro Deluxe and Ultra-Micro Hot Spot phantoms, and 2 healthy mice. The system average energy resolution was 14% at 511 keV. The average spatial resolution at the center of the field of view was about 1.2 mm, improving to 0.8 mm and remaining below 1.2 mm in the central 6-cm field of view when a resolution-recovery method was used. The absolute sensitivity of the camera was 6.38% for an energy window of 350-650 keV and a coincidence timing window of 3.4 ns. The system scatter fraction was 11.9% for the NEMA mouselike phantom and 28% for the ratlike phantom. The maximum noise-equivalent counting rate was 1,100 at 57 MBq for the mouselike phantom and 352 kcps at 65 MBq for the ratlike phantom. The 1-mm fillable rod was clearly observable using the NEMA image-quality phantom. The images of the Ultra-Micro Hot Spot phantom also showed the 1-mm hot rods. In the mouse studies, both the left and right ventricle walls were clearly observable, as were the Harderian glands. The MuPET camera has excellent resolution, sensitivity, counting rate, and imaging performance. The data show it is a powerful scanner for preclinical animal study and pharmaceutical development.

  4. One-pot synthesis and biodistribution of fluorine-18 labeled serum albumin for vascular imaging.

    PubMed

    Basuli, Falguni; Zhang, Xiang; Williams, Mark R; Seidel, Jurgen; Green, Michael V; Choyke, Peter L; Swenson, Rolf E; Jagoda, Elaine M

    2018-05-30

    Equilibrium single-photon radionuclide imaging methods for assessing cardiac function and the integrity of the vascular system have long been in use for both clinical and research purposes. However, positron-emitting blood pool agents that could provide PET equivalents to these (and other) clinical procedures have not yet been adopted despite technical imaging advantages offered by PET. Our goal was to develop a PET blood pool tracer that not only meets necessary in vivo biological requirements but can be produced with an uncomplicated and rapid synthesis method which would facilitate clinical translation. Herein, albumin labeled with fluorine-18 was synthesized using a one-pot method and evaluated in vitro and in vivo in rats. A ligand (NODA-Bz-TFPE), containing NODA attached to a tetrafluorophenylester (TFPE) via a phenyl linker (Bz), was labeled with aluminum fluoride (Al[ 18 F]F). Conjugation of the serum albumin with the ligand (Al[ 18 F]F-NODA-Bz-TFPE), followed by purification (size exclusion chromatography), yielded the final product (Al[ 18 F]F-NODA-Bz-RSA/HSA). In vitro stability was evaluated in human serum albumin by HPLC. Rat biodistributions and whole-body PET imaging over a 4 h time course were used for the in vivo evaluation. This synthesis exhibited an overall radiochemical yield of 45 ± 10% (n = 30), a 50-min radiolabeling time, a radiochemical purity >99% and apparent stability up to 4 h in human serum. Blood had the highest retention of Al[ 18 F]F-NODA-Bz-RSA at all times with a blood half-life of 5.2 h in rats. Al[ 18 F]F-NODA-Bz-RSA distribution in most rat tissues remained relatively constant for up to 1 h, indicating that the tissue radioactivity content represents the respective tissue plasma volume. Dynamic whole-body PET images were in agreement with these findings. A new ligand has been developed and radiolabeled with Al[ 18 F]F that allows rapid (50-min) preparation of fluorine-18 serum albumin in one-pot. In addition to increased synthetic efficiency, the construct appears to be metabolically stable in rats. This method could encourage wider use of PET to quantify cardiac function and tissue vascular integrity in both research and clinical settings. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. The Impact of Rendered Protein Meal Oxidation Level on Shelf-Life, Sensory Characteristics, and Acceptability in Extruded Pet Food

    PubMed Central

    Chanadang, Sirichat; Koppel, Kadri; Aldrich, Greg

    2016-01-01

    Simple Summary Sensory analysis was used to determine the changes due to the storage time on extruded pet food prepared from two different rendered protein meals: (i) beef meat and bone meal (BMBM); (ii) chicken byproduct meal (CPBM). Extrusion is a process where feed is pressed through a die in order to create shapes and increase digestibility. Descriptive sensory analysis using a human panel found an increase in undesirable sensory attributes (e.g., oxidized oil, rancid) in extruded pet food over storage time, especially the one prepared from chicken by product meal without antioxidants. The small increase in oxidized and rancid aromas of BMBM samples did not affect pet owners’ acceptability of the products. CPBM samples without antioxidants showed a notable increase in oxidized and rancid aroma over storage time and, thus, affected product acceptability negatively. This finding indicated that human sensory analysis can be used as a tool to track the changes of pet food characteristics due to storage, as well as estimate the shelf-life of the products. Abstract Pet foods are expected to have a shelf-life for 12 months or more. Sensory analysis can be used to determine changes in products and to estimate products’ shelf-life. The objectives of this study were to (1) investigate how increasing levels of oxidation in rendered protein meals used to produce extruded pet food affected the sensory properties and (2) determine the effect of shelf-life on pet owners’ acceptability of extruded pet food diet formulated without the use of preservative. Pet food diets contained beef meat bone meal (BMBM) and chicken byproduct meal (CBPM) in which the oxidation was retarded with ethoxyquin, mixed tocopherols, or none at all, and then extruded into dry pet foods. These samples represented low, medium, and high oxidation levels, respectively. Samples were stored for 0, 3, 6, 9, and 12 months at ambient temperature. Each time point, samples were evaluated by six highly trained descriptive panelists for sensory attributes related to oxidation. Samples without preservatives were chosen for the acceptability test, since the differences in sensory characteristics over storage time were more distinguishable in those samples. Pet owners evaluated samples for aroma, appearance and overall liking. Descriptive sensory analysis detected significant changes in oxidized-related sensory characteristics over storage time. However, the differences for CBPM samples were more pronounced and directional. The consumer study showed no differences in pet owners’ acceptability for BMBM samples. However, the noticeable increase in aroma characteristics (rancid aroma 0.33–4.21) in CBPM samples over storage time did have a negative effect on consumer’s liking (overall liking 5.52–4.95). PMID:27483326

  6. About climate variabilitiy leading the hydric condition of the soil in the rainfed region of Argentina

    NASA Astrophysics Data System (ADS)

    Pántano, V. C.; Penalba, O. C.

    2013-05-01

    Extreme events of temperature and rainfall have a socio-economic impact in the rainfed agriculture production region in Argentina. The magnitude of the impact can be analyzed through the water balance which integrates the characteristics of the soil and climate conditions. Changes observed in climate variables during the last decades affected the components of the water balance. As a result, a displacement of the agriculture border towards the west was produced, improving the agricultural production of the region. The objective of this work is to analyze how the variability of rainfall and temperature leads the hydric condition of the soil, with special focus on extreme events. The hydric conditions of the soil (HC= Excess- Deficit) were estimated from the monthly water balance (Thornthwaite and Mather method, 1957), using monthly potential evapotranspiration (PET) and monthly accumulated rainfall (R) for 33 stations (period 1970-2006). Information of temperature and rainfall was provided by National Weather Service and the effective capacity of soil water was considered from Forte Lay and Spescha (2001). An agricultural extreme condition occurs when soil moisture and rainfall are inadequate or excessive for the development of the crops. In this study, we define an extreme event when the variable is less (greater) than its 20% and 10% (80% and 90%) percentile. In order to evaluate how sensitive is the HC to water and heat stress in the region, different conditional probabilities were evaluated. There is a weaker response of HC to extreme low PET while extreme low R leads high values of HC. However, this behavior is not always observed, especially in the western region where extreme high and low PET show a stronger influence over the HC. Finally, to analyze the temporal variability of extreme PET and R, leading hydric condition of the soil, the number of stations presenting extreme conditions was computed for each month. As an example, interesting results were observed for April. During this month, the water recharge of the soil is crucial to let the winter crops manage with the scarce rainfalls occurring in the following months. In 1970, 1974, 1977, 1978 and 1997 more than 50% of the stations were under extreme high PET; while 1970, 1974, 1978 and 1988 presented more than 40% under extreme low R. Thus, the 70s was the more threatened decade of the period. Since the 80s (except for 1997), extreme dry events due to one variable or the other are mostly presented separately, over smaller areas. The response of the spatial distribution of HC is stronger when both variables present extreme conditions. In particular, during 1997 the region presents extreme low values of HC as a consequence of extreme low R and high PET. Communities dependent on agriculture are highly sensitive to climate variability and its extremes. In the studied region, it was shown that scarce water and heat stress contribute to the resulting hydric condition, producing strong impact over different productive activities. Extreme temperature seems to have a stronger influence over extreme unfavorable hydric conditions.

  7. Quantifying environmental limiting factors on tree cover using geospatial data.

    PubMed

    Greenberg, Jonathan A; Santos, Maria J; Dobrowski, Solomon Z; Vanderbilt, Vern C; Ustin, Susan L

    2015-01-01

    Environmental limiting factors (ELFs) are the thresholds that determine the maximum or minimum biological response for a given suite of environmental conditions. We asked the following questions: 1) Can we detect ELFs on percent tree cover across the eastern slopes of the Lake Tahoe Basin, NV? 2) How are the ELFs distributed spatially? 3) To what extent are unmeasured environmental factors limiting tree cover? ELFs are difficult to quantify as they require significant sample sizes. We addressed this by using geospatial data over a relatively large spatial extent, where the wall-to-wall sampling ensures the inclusion of rare data points which define the minimum or maximum response to environmental factors. We tested mean temperature, minimum temperature, potential evapotranspiration (PET) and PET minus precipitation (PET-P) as potential limiting factors on percent tree cover. We found that the study area showed system-wide limitations on tree cover, and each of the factors showed evidence of being limiting on tree cover. However, only 1.2% of the total area appeared to be limited by the four (4) environmental factors, suggesting other unmeasured factors are limiting much of the tree cover in the study area. Where sites were near their theoretical maximum, non-forest sites (tree cover < 25%) were primarily limited by cold mean temperatures, open-canopy forest sites (tree cover between 25% and 60%) were primarily limited by evaporative demand, and closed-canopy forests were not limited by any particular environmental factor. The detection of ELFs is necessary in order to fully understand the width of limitations that species experience within their geographic range.

  8. Exposure to antimony from polyethylene terephthalate (PET) trays used in ready-to-eat meals.

    PubMed

    Haldimann, M; Blanc, A; Dudler, V

    2007-08-01

    Antimony residues, a result of the use of a polycondensation catalyst in the production of polyethylene terephthalate (PET) oven-proof trays, were analysed in ready-to-eat meals. The toxicity of antimony has raised concerns about consumer safety; therefore, the migration of small fractions of these residues into ready meals and foods as a result of cooking directly in the PET trays was studied. A straightforward approach of measuring real samples was selected to obtain accurate exposure data. Background antimony concentration was determined separately from a series of lunch meals, which ranged from not detectable to 3.4 microg kg(-1). Microwave and conventional oven-cooking caused a distinct increase in the concentration of antimony in food and ready meals of 0-17 and 8-38 microg kg(-1), respectively, depending, to a certain extent, on the industrial preparations. The migrated quantities of antimony corresponded to 3-13 microg. For comparison, PET roasting bags and ready-made dough products in PET baking dishes were also evaluated. About half of the products prepared at a temperature of 180 degrees C exceeded the specific migration limit set for food contact material by the European Commission. However, the migrated amounts of antimony relative to the accepted tolerable daily intake (TDI) show that exposure from this type of food is currently not of toxicological concern.

  9. "New" Compounds from Old Plastics: Recycling PET Plastics via Depolymerization. An Activity for the Undergraduate Organic Lab

    NASA Astrophysics Data System (ADS)

    Kaufman, Don; Wright, Geoff; Kroemer, Ryan; Engel, Josh

    1999-11-01

    This paper describes work done to develop a meaningful undergraduate organic lab activity that illustrates chemistry of the real world while utilizing reactions typically included in the organic lecture and lab. We show how a common plastic can be converted into several compounds using ester hydrolysis and SN2 reactions. Contributing to the critical shortage of landfill space faced by many communities is the large quantity of plastic refuse. Thus, there is a real need to recycle plastic products. One way to recycle plastics such as polyethyleneterephthalate (PET), the polyester from which numerous consumer products such as 2-liter soda bottles are made, is to depolymerize them and then to use the resulting monomers to produce new products. PET is industrially depolymerized via an acid-catalyzed transesterification reaction conducted under conditions of high temperature and pressure that are not feasible in the undergraduate lab. Despite literature reports that PET is remarkably resistant to hydrolysis, we found that PET can be readily hydrolyzed by refluxing with potassium hydroxide or potassium tert-butoxide in amyl alcohol to give terephthalic acid in high yield. It is then possible to readily synthesize terephthalate diesters via SN2 reactions of ammonium terephthalate salts with alkyl halides. Fischer esterification can also be used to prepare the diesters, but yields are significantly lower.

  10. Novel Bifunctional Cyclic Chelator for 89Zr Labeling–Radiolabeling and Targeting Properties of RGD Conjugates

    PubMed Central

    2015-01-01

    Within the last years 89Zr has attracted considerable attention as long-lived radionuclide for positron emission tomography (PET) applications. So far desferrioxamine B (DFO) has been mainly used as bifunctional chelating system. Fusarinine C (FSC), having complexing properties comparable to DFO, was expected to be an alternative with potentially higher stability due to its cyclic structure. In this study, as proof of principle, various FSC-RGD conjugates targeting αvß3 integrins were synthesized using different conjugation strategies and labeled with 89Zr. In vitro stability, biodistribution, and microPET/CT imaging were evaluated using [89Zr]FSC-RGD conjugates or [89Zr]triacetylfusarinine C (TAFC). Quantitative 89Zr labeling was achieved within 90 min at room temperature. The distribution coefficients of the different radioligands indicate hydrophilic character. Compared to [89Zr]DFO, [89Zr]FSC derivatives showed excellent in vitro stability and resistance against transchelation in phosphate buffered saline (PBS), ethylenediaminetetraacetic acid solution (EDTA), and human serum for up to 7 days. Cell binding studies and biodistribution as well as microPET/CT imaging experiments showed efficient receptor-specific targeting of [89Zr]FSC-RGD conjugates. No bone uptake was observed analyzing PET images indicating high in vivo stability. These findings indicate that FSC is a highly promising chelator for the development of 89Zr-based PET imaging agents. PMID:25941834

  11. Wind shear and wet and dry thermodynamic indices as predictors of thunderstorm motion and severity and application to the AVE 4 experimental data

    NASA Technical Reports Server (NTRS)

    Connell, J. R.; Ey, L.

    1977-01-01

    Two types of parameters are computed and mapped for use in assessing their individual merits as predictors of occurrence and severity of thunderstorms. The first group is comprised of equivalent potential temperature, potential temperature, water vapor mixing ratio, and wind speed. Equivalent potential temperature maxima and strong gradients of equivalent potential temperature at the surface correlate well with regions of thunderstorm activity. The second type, comprised of the energy index, shear index, and energy shear index, incorporates some model dynamics of thunderstorms, including nonthermodynamic forcing. The energy shear index is found to improve prediction of tornadic and high-wind situations slightly better than other indices. It is concluded that further development and refinement of nonthermodynamic aspects of predictive indices are definitely warranted.

  12. Effects of oxide additions and temperature on sinterability of milled silicon nitride

    NASA Technical Reports Server (NTRS)

    Arias, A.

    1980-01-01

    Specimens of milled alpha-Si3N4 with 0 to 5.07 equivalent percent of oxide additions were pressureless sintered at 1650 to 1820 C for 4 hours in nitrogen while covered with powdered Si3N4 + SiO2. Densities of less than or equal to 97.5 percent resulted with approximately 2.5 equivalent percent of MgO, CeO2, Y2O3, and three mixtures involving these oxides. Densities of greater than or equal to 94 percent were obtained with approximately 0.62 equivalent percent of the same additives. At most temperatures, best sinterability (density maxima) was obtained with 1.2 to 2.5 equivalent percent additive.

  13. A disposable laser print-cut-laminate polyester microchip for multiplexed PCR via infra-red-mediated thermal control.

    PubMed

    Ouyang, Yiwen; Duarte, Gabriela R M; Poe, Brian L; Riehl, Paul S; dos Santos, Fernando M; Martin-Didonet, Claudia C G; Carrilho, Emanuel; Landers, James P

    2015-12-11

    Infrared (IR)-mediated thermal cycling system, a method proven to be a effective for sub-μL scale polymerase chain reaction (PCR) on microchips, has been integrated with DNA extraction and separation on a glass microchip in a fully integrated micro Total Analysis System by Easley et al., in 2006. IR-PCR has been demonstrated on both glass and PMMA microdevices where the fabrication (bonding) is not trivial. Polyester-toner (PeT) microfluidic devices have significant potential as cost-effective, disposable microdevices as a result of the ease of fabrication (∼$0.25 USD and <10 min per device) and availability of commercial substrates. For the first time, we demonstrate here the thermal cycling in PeT microchips on the IR-PCR system. Undesirable IR absorption by the black-toner bonding layer was eliminated with a spatial filter in the form of an aluminum foil mask. The solution heating rate for a black PeT microchip using a tungsten lamp was 10.1 ± 0.7 °C s(-1) with a cooling rate of roughly -12 ± 0.9 °C s(-1) assisted by forced air cooling. Dynamic surface passivation strategies allowed the successful amplification of a 520 bp fragment of the λ-phage genome (in 11 min) and a 1500 bp region of Azospirillum brasilense. Using a centrosymmetric chamber configuration in a multichamber PeT microchip, homogenous temperature distribution over all chambers was achieved with inter-chamber temperature differences at annealing, extension and denaturing steps of less than ±2 °C. The effectiveness of the multichamber system was demonstrated with the simultaneous amplification of a 390 bp amplicon of human β-globin gene in five PeT PCR microchambers. The relative PCR amplification efficiency with a human β-globin DNA fragment ranged from 70% to 90%, in comparison to conventional thermal cyclers, with an inter-chamber standard deviation of ∼10%. Development of PeT microchips for IR-PCR has the potential to provide rapid, low-volume amplification while also integrating PCR with extraction upstream and separation/detection downstream. Copyright © 2015. Published by Elsevier B.V.

  14. Al18F-Labeling Of Heat-Sensitive Biomolecules for Positron Emission Tomography Imaging.

    PubMed

    Cleeren, Frederik; Lecina, Joan; Ahamed, Muneer; Raes, Geert; Devoogdt, Nick; Caveliers, Vicky; McQuade, Paul; Rubins, Daniel J; Li, Wenping; Verbruggen, Alfons; Xavier, Catarina; Bormans, Guy

    2017-01-01

    Positron emission tomography (PET) using radiolabeled biomolecules is a translational molecular imaging technology that is increasingly used in support of drug development. Current methods for radiolabeling biomolecules with fluorine-18 are laborious and require multistep procedures with moderate labeling yields. The Al 18 F-labeling strategy involves chelation in aqueous medium of aluminum mono[ 18 F]fluoride ({Al 18 F} 2+ ) by a suitable chelator conjugated to a biomolecule. However, the need for elevated temperatures (100-120 °C) required for the chelation reaction limits its widespread use. Therefore, we designed a new restrained complexing agent (RESCA) for application of the AlF strategy at room temperature. Methods. The new chelator RESCA was conjugated to three relevant biologicals and the constructs were labeled with {Al 18 F} 2+ to evaluate the generic applicability of the one-step Al 18 F-RESCA-method. Results. We successfully labeled human serum albumin with excellent radiochemical yields in less than 30 minutes and confirmed in vivo stability of the Al 18 F-labeled protein in rats. In addition, we efficiently labeled nanobodies targeting the Kupffer cell marker CRIg, and performed µPET studies in healthy and CRIg deficient mice to demonstrate that the proposed radiolabeling method does not affect the functional integrity of the protein. Finally, an affibody targeting HER2 (PEP04314) was labeled site-specifically, and the distribution profile of (±)-[ 18 F]AlF(RESCA)-PEP04314 in a rhesus monkey was compared with that of [ 18 F]AlF(NOTA)-PEP04314 using whole-body PET/CT. Conclusion. This generic radiolabeling method has the potential to be a kit-based fluorine-18 labeling strategy, and could have a large impact on PET radiochemical space, potentially enabling the development of many new fluorine-18 labeled protein-based radiotracers.

  15. Targeting Presynaptic Norepinephrine Transporter in Brown Adipose Tissue: A Novel Imaging Approach and Potential Treatment for Diabetes and Obesity

    PubMed Central

    MIRBOLOOKI, M. REZA; CONSTANTINESCU, CRISTIAN C.; PAN, MIN-LIANG; MUKHERJEE, JOGESHWAR

    2013-01-01

    Brown adipose tissue (BAT) plays a significant role in metabolism. In this study, we report the use of atomoxetine (a clinically applicable norepinephrine reuptake inhibitor) for 18F-FDG PET imaging of BAT and its effects on heat production and blood glucose concentration. Fasted-male Sprague-Dawley rats were administered with intravenous 18F-FDG. The same rats were treated with atomoxetine (0.1 mg/kg, i.v.) 30 min before 18F-FDG administration. To confirm the β-adrenergic effects, propranolol (β-adrenergic inhibitor) 5 mg/kg was given intraperitoneally 30 min prior to atomoxetine administration. The effect of atomoxetine on BAT metabolism was assessed in fasted and non-fasted rats and on BAT temperature and blood glucose in fasted rats. In 18F-FDG PET/CT images, interscapular BAT (IBAT) and other areas of BAT were clearly visualized. When rats were fasted, atomoxetine (0.1 mg/kg) increased the 18F-FDG uptake of IBAT by factor of 24 within 30 min. Propranolol reduced the average 18F-FDG uptake of IBAT significantly. Autoradiography of IBAT and white adipose tissue confirmed the data obtained by PET. When rats were not fasted, atomoxetine-induced increase of 18F-FDG uptake in IBAT was delayed and occurred in 120 min. For comparison, direct stimulation of β3-adrenreceptors in non-fasted rats with CL-316, 243 occurred within 30 min. Atomoxetine-induced IBAT activation was associated with higher IBAT temperature and lower blood glucose. This was mediated by inhibition of norepinephrine reuptake transporters in IBAT leading to increased norepinephrine concentration in the synapse. Increased synaptic norepinephrine activates β3-adrenreceptors resulting in BAT hypermetabolism that is visible and quantifiable by 18F-FDG PET/CT. PMID:23080264

  16. An interior-point method for total variation regularized positron emission tomography image reconstruction

    NASA Astrophysics Data System (ADS)

    Bai, Bing

    2012-03-01

    There has been a lot of work on total variation (TV) regularized tomographic image reconstruction recently. Many of them use gradient-based optimization algorithms with a differentiable approximation of the TV functional. In this paper we apply TV regularization in Positron Emission Tomography (PET) image reconstruction. We reconstruct the PET image in a Bayesian framework, using Poisson noise model and TV prior functional. The original optimization problem is transformed to an equivalent problem with inequality constraints by adding auxiliary variables. Then we use an interior point method with logarithmic barrier functions to solve the constrained optimization problem. In this method, a series of points approaching the solution from inside the feasible region are found by solving a sequence of subproblems characterized by an increasing positive parameter. We use preconditioned conjugate gradient (PCG) algorithm to solve the subproblems directly. The nonnegativity constraint is enforced by bend line search. The exact expression of the TV functional is used in our calculations. Simulation results show that the algorithm converges fast and the convergence is insensitive to the values of the regularization and reconstruction parameters.

  17. Performance evaluation and optimization of the MiniPET-II scanner

    NASA Astrophysics Data System (ADS)

    Lajtos, Imre; Emri, Miklos; Kis, Sandor A.; Opposits, Gabor; Potari, Norbert; Kiraly, Beata; Nagy, Ferenc; Tron, Lajos; Balkay, Laszlo

    2013-04-01

    This paper presents results of the performance of a small animal PET system (MiniPET-II) installed at our Institute. MiniPET-II is a full ring camera that includes 12 detector modules in a single ring comprised of 1.27×1.27×12 mm3 LYSO scintillator crystals. The axial field of view and the inner ring diameter are 48 mm and 211 mm, respectively. The goal of this study was to determine the NEMA-NU4 performance parameters of the scanner. In addition, we also investigated how the calculated parameters depend on the coincidence time window (τ=2, 3 and 4 ns) and the low threshold settings of the energy window (Elt=250, 350 and 450 keV). Independent measurements supported optimization of the effective system radius and the coincidence time window of the system. We found that the optimal coincidence time window and low threshold energy window are 3 ns and 350 keV, respectively. The spatial resolution was close to 1.2 mm in the center of the FOV with an increase of 17% at the radial edge. The maximum value of the absolute sensitivity was 1.37% for a point source. Count rate tests resulted in peak values for the noise equivalent count rate (NEC) curve and scatter fraction of 14.2 kcps (at 36 MBq) and 27.7%, respectively, using the rat phantom. Numerical values of the same parameters obtained for the mouse phantom were 55.1 kcps (at 38.8 MBq) and 12.3%, respectively. The recovery coefficients of the image quality phantom ranged from 0.1 to 0.87. Altering the τ and Elt resulted in substantial changes in the NEC peak and the sensitivity while the effect on the image quality was negligible. The spatial resolution proved to be, as expected, independent of the τ and Elt. The calculated optimal effective system radius (resulting in the best image quality) was 109 mm. Although the NEC peak parameters do not compare favorably with those of other small animal scanners, it can be concluded that under normal counting situations the MiniPET-II imaging capability assures remarkably good image quality, sensitivity and spatial resolution.

  18. One Health Solutions to Obesity in People and Their Pets.

    PubMed

    Bartges, J; Kushner, R F; Michel, K E; Sallis, R; Day, M J

    2017-05-01

    Despite the high prevalence of overweight and obesity in the human and companion animal populations, and the global trends for increasing numbers of affected people and pets, there are few successful interventions that are proven to combat this complex multifactorial problem. One key strategy involves effective communication between human and veterinary healthcare professionals with patients and clients about obesity. In human healthcare, the focus of communication should be on physical activity as part of overall health and wellbeing, rather than assessment of the body mass index; clinical examination of patients should record levels of physical activity as a key 'vital sign' as part of their assessment. Successful weight loss programmes for companion animals also involves strategic communication with the entire healthcare team leading clients through the 'stages of change'. There is great potential in employing a 'One Health' framework to provide novel solutions for the prevention and treatment of this condition in people and their pets. Comparative clinical research into the biology of obesity and its comorbidities in dogs and cats is likely to lead to knowledge relevant to the equivalent human conditions. The advantages of companion animal clinical research over traditional rodent models include the outbred genetic background and relatively long lifespan of pets and the fact that they share the human domestic environment. The human-companion animal bond can be leveraged to create successful programmes that promote physical activity in people and their pets with obesity. Dog walking is a proven motivator for human physical activity, with health benefits to both the owner and the dog. Realizing the potential of a One Health approach will require the efforts and leadership of a committed group of like-minded individuals representing a range of scientific and medical disciplines. Interested parties will need the means and opportunities to communicate and to collaborate, including having the resources and funding for research. One Health proponents must have a role in forming public policy related to the prevention and management of overweight and obesity. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  19. Recent climate trends and implications for water resources in the Catskill Mountain region, New York, USA

    USGS Publications Warehouse

    Burns, Douglas A.; Klaus, Julian; McHale, Michael R.

    2007-01-01

    Climate scientists have concluded that the earth’s surface air temperature warmed by 0.6 °C during the 20th century, and that warming induced by increasing concentrations of greenhouse gases is likely to continue in the 21st century, accompanied by changes in the hydrologic cycle. Climate change has important implications in the Catskill region of southeastern New York State, because the region is a source of water supply for New York City. We used the non-parametric Mann–Kendall test to evaluate annual, monthly, and multi-month trends in air temperature, precipitation amount, stream runoff, and potential evapotranspiration (PET) in the region during 1952–2005 based on data from 9 temperature sites, 12 precipitation sites, and 8 stream gages. A general pattern of warming temperatures and increased precipitation, runoff, and PET is evident in the region. Regional annual mean air temperature increased significantly by 0.6 °C per 50 years during the period; the greatest increases and largest number of significant upward trends were in daily minimum air temperature. Daily maximum air temperature showed the greatest increase during February through April, whereas minimum air temperature showed the greatest increase during May through September. Regional mean precipitation increased significantly by 136 mm per 50 years, nearly double that of the regional mean increase in runoff, which was not significant. Regional mean PET increased significantly by 19 mm per 50 years, about one-seventh that of the increase in precipitation amount, and broadly consistent with increased runoff during 1952–2005, despite the lack of significance in the mean regional runoff trend. Peak snowmelt as approximated by the winter–spring center of volume of stream runoff generally shifted from early April at the beginning of the record to late March at the end of the record, consistent with a decreasing trend in April runoff and an increasing trend in maximum March air temperature. This change indicates an increased supply of water to reservoirs earlier in the year. Additionally, the supply of water to reservoirs at the beginning of winter is greater as indicated by the timing of the greatest increases in precipitation and runoff—both occurred during summer and fall. The future balance between changes in air temperature and changes in the timing and amount of precipitation in the region will have important implications for the available water supply in the region.

  20. Staying safe at home

    MedlinePlus

    ... gas company right away. Furnace: Keep the air supply vent clear of obstructions. Replace the furnace filter at least every 3 months when in use. Change it every month if you have allergies or pets. Water heater: Set the temperature no higher than 120 ...

  1. First results of a highly granulated 3D CdTe detector module for PET

    NASA Astrophysics Data System (ADS)

    Chmeissani, Mokhtar; Kolstein, Machiel; Macias-Montero, José Gabriel; Puigdengoles, Carles; García, Jorge; Prats, Xavier; Martínez, Ricardo

    2018-01-01

    We present the performance of a highly granulated 3D detector module for PET, consisting of a stack of pixelated CdTe detectors. Each detector module has 2 cm  ×  2 cm  ×  2 cm of CdTe material, subdivided into 4000 voxels, where each voxel has size 1 mm  ×  1 mm  ×  2 mm and is connected to its own read-out electronics via a BiSn solder ball. Each read-out channel consists of a preamp, a discriminator, a shaper, a peak-and-hold circuit and a 10 bits SAR ADC. The preamp has variable gain where at the maximum gain the ADC resolution is equivalent to 0.7 keV. Each ASIC chip reads 100 CdTe pixel channels and has one TDC to measure the time stamp of the triggered events, with a time resolution of less than 1 ns. With the bias voltage set at  -250 V mm-1 and for 17838 working channels out of a total of 20 000, we have obtained an average energy resolution of 2.2% FWHM for 511 keV photons. For 511 keV photons that have undergone Compton scattering, we measured an energy resolution of 3.2% FWHM. A timing resolution for PET coincidence events of 60 ns FWHM was found.

  2. Pollutant emissions from flat-flame burners at high pressures

    NASA Technical Reports Server (NTRS)

    Maahs, H. G.; Miller, I. M.

    1980-01-01

    Maximum flame temperatures and pollutant emission measurements for NOx, CO, and UHC (unburned hydrocarbons) are reported for premixed methane air flat flames at constant total mass flow rate over the pressure range from 1.9 to 30 atm and for equivalence ratios from 0.84 to 1.12. For any given pressure, maxima typically occur in both the temperature and NOx emissions curves slightly to the lean side of stoichiometric conditions. The UHC emissions show minima at roughly the same equivalence ratios. The CO emissions, however, increase continually with increasing equivalence ratio. Flame temperature and NOx emissions decrease with increasing pressure, while the opposite is true for the CO and UHC emissions. The NOx data correlate reasonably well as a function of flame temperature only. Four flameholders, differing only slightly, were used. In general, the temperature and emissions data from these four flameholders are similar, but some differences also exist. These differences appear to be related to minor variations in the condition of the flameholder surfaces.

  3. Thermal fluctuation within nests and predicted sex ratio of Morelet's Crocodile.

    PubMed

    Escobedo-Galván, Armando H; López-Luna, Marco A; Cupul-Magaña, Fabio G

    2016-05-01

    Understanding the interplay between thermal variations and sex ratio in reptiles with temperature-dependent sex determination is the first step for developing long-term conservation strategies. In case of crocodilians, the information is fragmentary and insufficient for establishing a general framework to consider how thermal fluctuation influence sex determination under natural conditions. The main goal of this study was to analyze thermal variation in nests of Crocodylus moreletii and to discuss the potential implications for predicting offspring sex ratio. The study was carried out at the Centro de Estudios Tecnológicos del Mar N° 2 and at the Sistemas Productivos Cocodrilo, Campeche, Mexico. Data was collected in the nesting season of Morelet's Crocodiles during three consecutive seasons (2007-2009). Thermal fluctuations for multiple areas of the nest chamber were registered by data loggers. We calculate the constant temperature equivalent based on thermal profiles among nests to assess whether there are differences between the nest temperature and its equivalent to constant temperature. We observed that mean nest temperature was only different among nests, while daily thermal fluctuations vary depending on the depth position within the nest chamber, years and nests. The constant temperature equivalent was different among and within nests, but not among survey years. We observed differences between constant temperature equivalent and mean nest temperature both at the top and in the middle of the nest cavities, but were not significantly different at the bottom of nest cavities. Our results enable examine and discuss the relevance of daily thermal fluctuations to predict sex ratio of the Morelet's Crocodile. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Influence of evapotranspiration on thermal comfort in central European cities

    NASA Astrophysics Data System (ADS)

    Goldbach, A.; Kuttler, W.

    2012-04-01

    In future, more and more people will be exposed to the negative thermal effects of urban climate, which will be exacerbated by predicted climate change. In regard to urban climate studies, it is necessary to develop adaptation and mitigation strategies tailored to the problem area and to include them in the local planning process. Urban green spaces or water bodies could help to mitigate the radiation and air temperature. For this purpose eddy-covariance technique has been carried out in Oberhausen (Germany; 51° N, 6° E) between 15 August 2010 and 14 August 2011 to quantify turbulent sensible and latent heat fluxes in areas with various types of urban land use. The results show that sensible heat flux (QH) is 20 % higher, latent heat flux (QE) 90 % lower at the urban (URB) site compared to the suburban one (SUB). Furthermore, partition of the turbulent heat fluxes (QH/Q* resp. QE/Q*) clearly depends on plan area density (λP). The human-biometeorological thermal index, the physiologically equivalent temperature (PET), demonstrates that green spaces counteract growing thermal stress on city-dwellers due to improving thermal comfort. Aside from the positive effect of shading, inner-city green spaces can only be effective if an adequate water supply is ensured. Otherwise, the positive thermal effects of green spaces resulting from transpiration will be reduced to a minimum or eliminated entirely, which is confirmed by the measured values. Additional planning recommendations for urban planners within cities located at mid-latitudes derived from measuring results are given.

  5. Short term storage stability at room temperature of two different platelet-rich plasma preparations from equine donors and potential impact on growth factor concentrations.

    PubMed

    Hauschild, Gregor; Geburek, Florian; Gosheger, Georg; Eveslage, Maria; Serrano, Daniela; Streitbürger, Arne; Johannlükens, Sara; Menzel, Dirk; Mischke, Reinhard

    2017-01-05

    The increasing interest in platelet-rich plasma (PRP) based therapies is as yet accompanied by inconsistent information regarding nearly all aspects of handling and application. Among these storage stability of processed platelet-rich products may be the basis for a more flexible application mode. The objective of this study was (1) to estimate the storage stability of growth factors platelet derived growth factor BB (PDGF-BB) and transforming growth factor ß1 (TGF-ß1) in both, a single-step softspin centrifugation-based pure-PRP (P-PRP, ACP®), and a gravity filtration system-based leukocyte-rich-PRP (L-PRP, E-PET), over a six hours time span after preparation at room temperature and (2) to identify possible factors influencing these growth factor concentrations in an equine model. Growth factor concentrations remained stable over the entire investigation period in L-PRP as well as P-PRP preparations revealing a mean of 3569 pg/ml PDGF-BB for E-PET and means of 1276 pg/ml PDGF-BB and 5086 pg/ml TGF-ß1 for ACP®. Pearson correlations yielded no significant impact of whole blood platelet (PLT), white blood cell (WBC) and red blood cell (RBC) counts on resulting cytokine values. In case of ACP® no significant dependencies between PLT, WBC and RBC counts of the processed platelet-rich product and resulting cytokine content occurred with exception of TGF-ß1 concentrations showing a strong correlation with the WBC content. PDGF-BB content of E-PET preparations showed a strong positive correlation with PLT and a strong negative with WBC of these preparations but not with RBC. L-PRP ad modum E-PET and P-PRP ad modum ACP® are applicable over at least a six hours time span at room temperature without loss of growth factor content. Based on the results of this study factors influencing the resulting growth factor concentrations still remain questionable. Additional studies implicating a further standardization of preparation protocols are necessary to identify consistent impact on cytokine content after PRP processing.

  6. Ge14 Br8 (PEt3 )4 : A Subhalide Cluster of Germanium.

    PubMed

    Kunz, Tanja; Schrenk, Claudio; Schnepf, Andreas

    2018-04-03

    Heating a metastable solution of Ge I Br to room temperature led to the first structurally characterized metalloid subhalide cluster Ge 14 Br 8 (PEt 3 ) 4 (1). Furthermore 1 can be seen as the first isolated binary halide cluster on the way from Ge I Br to elemental germanium, giving insight into the complex reaction mechanism of its disproportionation reaction. Quantum chemical calculations further indicate that a classical bonding situation is realized within 1 and that the last step of the formation of 1 might include the trapping of GeBr 2 units. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Observation of fast scintillation of cryogenic PbI/sub 2/ with VLPCs

    NASA Astrophysics Data System (ADS)

    Moses, W. W.; Choong, W.-S.; Derenzo, S. E.; Bross, A. D.; Dysert, R.; Rykalin, V. V.; Shah, K. S.; Klugerman, M.

    2004-10-01

    At cryogenic temperatures (/spl sim/10 K), undoped lead iodide (PbI/sub 2/) has material and scintillation properties that are very attractive for positron emission tomography (PET). However, the PbI/sub 2/ emissions are quenched at temperatures >40 K, so close optical coupling between the scintillator and photodetector requires a photodetector that also operates at cryogenic temperatures. This suggests the visible light photon counter (VLPC), which operates at similar temperatures and combines high gain and high quantum efficiency. We proximity couple (0.001 in air gap) PbI/sub 2/ crystals with 1.0-2.5 mm dimensions to a 1 mm diameter VLPC and cool the system to 8.5 K. Signals with short (<10 ns) duration are observed. When excited with 511 keV photons, a coincidence timing resolution of 1.3 ns full-width at half-maximum is measured. While a clear photopeak is observed for 122 keV excitation, no clear photopeak is seen under 511 keV excitation (possibly due to the poor optical quality of the PbI/sub 2/ crystals). While the present configuration must be scaled-up considerably, a cryogenic PbI/sub 2//VLPC combination may eventually become the basis for a practical time-of-flight PET camera.

  8. Enhanced Wettability and Thermal Stability of a Novel Polyethylene Terephthalate-Based Poly(Vinylidene Fluoride) Nanofiber Hybrid Membrane for the Separator of Lithium-Ion Batteries.

    PubMed

    Zhu, Chunhong; Nagaishi, Tomoki; Shi, Jian; Lee, Hoik; Wong, Pok Yin; Sui, Jianhua; Hyodo, Kenji; Kim, Ick Soo

    2017-08-09

    In this study, a novel membrane for the separator in a lithium-ion (Li-ion) battery was proposed via a mechanically pressed process with a poly(vinylidene fluoride) (PVDF) nanofiber subject and polyethylene terephthalate (PET) microfiber support. Important physical properties, such as surface morphology, wettability, and heat stability were considered for the PET-reinforced PVDF nanofiber (PRPN) hybrid separator. Images of scanning electron microscopy (SEM) showed that the PRPN hybrid separator had a homogeneous pore size and high porosity. It can wet out in battery electrolytes completely and quickly, satisfying wettability requirements. Moreover, the electrolyte uptake was higher than that of dry-laid and wet-laid nonwovens. For heat stability, no shrink occurred even when the heating temperature reached 135 °C, demonstrating thermal and dimensional stability. Moreover, differential scanning calorimetry (DSC) showed that the PRPN hybrid separator possessed a shutdown temperature of 131 °C, which is the same as conventional separators. Also, the meltdown temperature reached 252 °C, which is higher than the shutdown temperature, and thus can protect against internal cell shorts. The proposed PRPN hybrid separator is a strong candidate material for utilization in Li-ion batteries.

  9. Whole-body biodistribution and radiation dosimetry of 18F-FP-(+)-DTBZ (18F-AV-133): a novel vesicular monoamine transporter 2 imaging agent.

    PubMed

    Lin, Kun-Ju; Weng, Yi-Hsin; Wey, Shiaw-Pyng; Hsiao, Ing-Tsung; Lu, Chin-Song; Skovronsky, Daniel; Chang, Hsiu-Ping; Kung, Mei-Ping; Yen, Tzu-Chen

    2010-09-01

    Vesicular monoamine transporter 2 (VMAT2) is highly expressed in the endocrine cells and brain. We investigated the biodistribution and radiation dosimetry of (2R,3R,11bR)-9-(3-(18)F-fluoropropoxy)-3-isobutyl-10-methoxy-2,3,4,6,7,11b-hexahydro-1H-pyrido[2,1-a]isoquinolin-2-ol ((18)F-FP-(+)-dihydrotetrabenazine [DTBZ] or (18)F-AV-133), a potential VMAT2 imaging agent showing encouraging results in humans, to facilitate its future clinical use. Nine healthy human subjects (mean age +/- SD, 58.6 +/- 4.2 y) were enrolled for the whole-body PET scan. Serial images were acquired for 3 h immediately after a bolus injection of 390.7 +/- 22.9 MBq of (18)F-AV-133 per individual. The source organs were delineated on PET/CT images. The OLINDA/EXM application was used to determine the equivalent dose for individual organs. The radiotracer did not show any noticeable adverse effects for the 9 subjects examined. The radioactivity uptake in the brain was the highest at 7.5% +/- 0.6% injected dose at 10 min after injection. High absorbed doses were found in the pancreas, liver, and upper large intestine wall. The highest-dosed organ, which received 153.3 +/- 23.8 microGy/MBq, was the pancreas. The effective dose equivalent and effective dose for (18)F-AV-133 were 36.5 +/- 2.8 and 27.8 +/- 2.5 microSv/MBq, respectively. These values are comparable to those reported for any other (18)F-labeled radiopharmaceutical. (18)F-AV-133 is safe, with appropriate biodistribution and radiation dosimetry for imaging VMAT2 sites in humans.

  10. Evaluation of taurine as an osmotic agent for peritoneal dialysis solution.

    PubMed

    Nishimura, Hideki; Ikehara, Osamu; Naito, Takashi; Higuchi, Chieko; Sanaka, Tsutomu

    2009-01-01

    The development of a glucose-free peritoneal dialysis (PD) solution is important because glucose has been associated with functional and morphological damage to the peritoneal membrane. The ultrafiltration (UF) and biocompatibility of new PD solutions containing taurine (PD-taurine) instead of glucose as an osmolite were tested in a rat PD model. To determine the solution's UF ability, different concentrations of taurine in PD solutions were compared to glucose-based PD solutions (PD-glucose) by giving single intraperitoneal injections for 2, 4, and 6 hours. To examine the biocompatibility of PD-taurine, the rats were divided into 3 groups: a 3.86% PD-glucose group, a 3.5% PD-taurine group and a not dialyzed group. The rats were given 10-mL injections of PD fluids intraperitoneally 3 times daily for 7 days. A peritoneal equilibration test (PET) was performed using a 1.9% xylitol solution at the time the rats were sacrificed. Mesothelial cell monolayers were obtained from the animals and studied based on a population analysis. The net UF of PD-taurine increased in a dose-dependent manner; the 3.5% PD-taurine solution was equivalent to the 3.86% PD-glucose solution after 4 hours. The PET showed that the drainage volume and the D(4)/D(0) ratio for xylitol after 4 hours with PD-taurine solution were significantly greater than with the PD-glucose solution (p < 0.001 and p < 0.001 respectively). Mesothelial and fibroblast-like cell proliferation was significantly less with PD-taurine than with PD-glucose (p < 0.01). These results indicate that PD-taurine resulted in net UF equivalent to that of PD-glucose and was more biocompatible than PD-glucose with respect to the peritoneal membrane.

  11. Seasonal influence on stimulated BAT activity in prospective trials: a retrospective analysis of BAT visualized on 18F-FDG PET-CTs and 123I-mIBG SPECT-CTs.

    PubMed

    Bahler, Lonneke; Deelen, Jan W; Hoekstra, Joost B; Holleman, Frits; Verberne, Hein J

    2016-06-15

    Retrospective studies have shown that outdoor temperature influences the prevalence of detectable brown adipose tissue (BAT). Prospective studies use acute cold exposure to activate BAT. In prospective studies, BAT might be preconditioned in winter months leading to an increased BAT response to various stimuli. Therefore the aim of this study was to assess whether outdoor temperatures and other weather characteristics modulate the response of BAT to acute cold. To assess metabolic BAT activity and sympathetic outflow to BAT, 64 (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography-computed tomography (PET-CT) and 56 additional (123)I-meta-iodobenzylguanidine ((123)I-mIBG) single-photon emission computed tomography-CT (SPECT-CT) scans, respectively, of subjects participating in previously executed trials were retrospectively included. BAT activity was measured in subjects after an overnight fast, following 2 h of cold exposure (∼17°C). The average daytime outdoor temperatures and other weather characteristics were obtained from the Dutch Royal Weather Institute. Forty-nine subjects were BAT positive. One week prior to the scan, outdoor temperature was significantly lower in the BAT-positive group compared with the BAT-negative group. Higher outdoor temperatures on preceding days resulted in lower stimulated metabolic BAT activity and volume (all P < 0.01). Outdoor temperatures did not correlate with sympathetic outflow to BAT. In conclusion, outdoor temperatures influence metabolic BAT activity and volume, but not sympathetic outflow to BAT, in subjects exposed to acute cold. To improve the consistency of the findings of future BAT studies in humans and to exclude bias introduced by outdoor temperatures, these studies should be planned in periods of similar outdoor temperatures. Copyright © 2016 the American Physiological Society.

  12. 40 CFR 86.1804-01 - Acronyms and abbreviations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...—Nonmethane Hydrocarbons. NMHCE—Non-Methane Hydrocarbon Equivalent. NMOG—Non-methane organic gases. NO—nitric....—Degree(s). DNPH—2,4-dinitrophenylhydrazine. EDV—Emission Data Vehicle. EP—End point. ETW—Equivalent test...—dispensed fuel temperature. THC—Total Hydrocarbons. THCE—Total Hydrocarbon Equivalent. TLEV—Transitional Low...

  13. 40 CFR 86.1804-01 - Acronyms and abbreviations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...—Nonmethane Hydrocarbons. NMHCE—Non-Methane Hydrocarbon Equivalent. NMOG—Non-methane organic gases. NO—nitric....—Degree(s). DNPH—2,4-dinitrophenylhydrazine. EDV—Emission Data Vehicle. EP—End point. ETW—Equivalent test...—dispensed fuel temperature. THC—Total Hydrocarbons. THCE—Total Hydrocarbon Equivalent. TLEV—Transitional Low...

  14. The use of radiation-induced graft polymerization for modification of polymer track membranes

    NASA Astrophysics Data System (ADS)

    Shtanko, N. I.; Kabanov, V. Ya.; Apel, P. Yu.; Yoshida, M.

    1999-05-01

    Track membranes (TM) made of poly(ethylene terephtalate) (PET) and polypropylene (PP) films have a number of peculiarities as compared with other ones. They have high mechanical strength at a low thickness, narrow pore size distribution, low content of extractables. However, TM have some disadvantages such as low chemical resistance in alkaline media (PET TM), the low water flow rate due to the hydrophobic nature of their surface. The use of radiation-induced graft polymerization makes it possible to improve the basic characteristics of TM. In this communication our results on the modification of PET and PP TM are presented. The modified membranes were prepared by radiation-induced graft polymerization from the liquid phase. Three methods of grafting were used: (a) the direct method in argon atmosphere; (b) the pre-irradiation of TM in air followed by grafting in argon atmosphere; (c) pre-irradiation in vacuum followed by grafting in vacuum without contacting oxygen. The aim of the work was to investigate some properties of TM modified by grafted poly(methylvinyl pyridine) (PMVP) and poly(N-isopropylacrylamide) (PNIPAAM). It was shown that the modification of TM with hydrophilic polymer results in the growth of the water flow rate. In the past few years many works have been devoted to the synthesis of new polymers - the so-called "intelligent" materials - such as PNIPAAM. However, it is very difficult to make thin membranes of this polymer. Recently, it has been proposed to manufacture composite membranes by grafting stimulus-responsive polymers onto TM. Following this principle, we prepared thermosensitive membranes by the radiation-induced graft polymerization of N-isopropylacrylamide (NIPAAM) onto PET TM. PET TM with the pore size of about 1 μm and pore density of 10 6 cm -2 were first inserted into a solution of NIPAAM containing inhibitor of homopolymerization (CuCl 2) and then exposed to the γ-rays from a 60Co source. The transport properties of the grafted TM were investigated. The permeation of water through the TM was controlled by temperature. The grafted TM exhibited almost the same transition temperature (about 33°C) as that of PNIPAAM.

  15. Real-Time Microfluidic Blood-Counting System for PET and SPECT Preclinical Pharmacokinetic Studies.

    PubMed

    Convert, Laurence; Lebel, Réjean; Gascon, Suzanne; Fontaine, Réjean; Pratte, Jean-François; Charette, Paul; Aimez, Vincent; Lecomte, Roger

    2016-09-01

    Small-animal nuclear imaging modalities have become essential tools in the development process of new drugs, diagnostic procedures, and therapies. Quantification of metabolic or physiologic parameters is based on pharmacokinetic modeling of radiotracer biodistribution, which requires the blood input function in addition to tissue images. Such measurements are challenging in small animals because of their small blood volume. In this work, we propose a microfluidic counting system to monitor rodent blood radioactivity in real time, with high efficiency and small detection volume (∼1 μL). A microfluidic channel is built directly above unpackaged p-i-n photodiodes to detect β-particles with maximum efficiency. The device is embedded in a compact system comprising dedicated electronics, shielding, and pumping unit controlled by custom firmware to enable measurements next to small-animal scanners. Data corrections required to use the input function in pharmacokinetic models were established using calibrated solutions of the most common PET and SPECT radiotracers. Sensitivity, dead time, propagation delay, dispersion, background sensitivity, and the effect of sample temperature were characterized. The system was tested for pharmacokinetic studies in mice by quantifying myocardial perfusion and oxygen consumption with (11)C-acetate (PET) and by measuring the arterial input function using (99m)TcO4 (-) (SPECT). Sensitivity for PET isotopes reached 20%-47%, a 2- to 10-fold improvement relative to conventional catheter-based geometries. Furthermore, the system detected (99m)Tc-based SPECT tracers with an efficiency of 4%, an outcome not possible through a catheter. Correction for dead time was found to be unnecessary for small-animal experiments, whereas propagation delay and dispersion within the microfluidic channel were accurately corrected. Background activity and sample temperature were shown to have no influence on measurements. Finally, the system was successfully used in animal studies. A fully operational microfluidic blood-counting system for preclinical pharmacokinetic studies was developed. Microfluidics enabled reliable and high-efficiency measurement of the blood concentration of most common PET and SPECT radiotracers with high temporal resolution in small blood volume. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. Improvement of indoor air quality in pet shop using gaseous chlorine dioxide.

    PubMed

    Lu, Ming-Chun; Huang, Da-Ji; Hsu, Ching-Shan; Liang, Chih-Kuo; Chen, Geng-Min

    2018-06-01

    Many studies have shown that pet shops have a high concentration of bioaerosols. Thus, effective disinfection protocols are essential to protect the pet shop staff and visitors to the store. The present study examines the effectiveness of gaseous chlorine dioxide (ClO 2 ) fogging in minimizing the residual bacteria and fungi levels in a typical pet shop in Taiwan consisting of a commodity area, a lodging area, and a grooming area. This investigation uses three disinfection modes (DMs) according to different disinfection periods, namely once every hour (1DM), once every 2 h (2DM), and once every 3 h (3DM). The bacteria and fungi concentrations are measured before and after disinfection treatment, and the effectiveness of each disinfection mode is evaluated using standard statistical techniques. To assess the effect of the environmental factors on the disinfection efficiency, measurements are taken of temperature, relative humidity, airflow velocity, the carbon dioxide concentration, the PM 1 , PM 2.5 , PM 7 , PM 10 , and TSP level at each sampling locations. The results reveal that the effectiveness of the three disinfection modes depends on both the environmental parameters and the use of the three areas (e.g., commodity, lodging, or grooming). Hence, the choice of disinfection method should be adjusted accordingly. For all three disinfection modes, a faster air velocity is beneficial in spreading the disinfectant throughout the indoor space and improving the disinfection performance. Overall, the results presented in this study confirm that gaseous chlorine dioxide disinfection improves the air quality in the pet shop interior, and thus beneficial in safeguarding the health of the pet shop staff and visitors.

  17. A high-performance protocol for extraction of microplastics in fish.

    PubMed

    Karami, Ali; Golieskardi, Abolfazl; Choo, Cheng Keong; Romano, Nicholas; Ho, Yu Bin; Salamatinia, Babak

    2017-02-01

    So far, several classes of digesting solutions have been employed to extract microplastics (MPs) from biological matrices. However, the performance of digesting solutions across different temperatures has never been systematically investigated. In the first phase of the present study, we measured the efficiency of different oxidative agents (NaClO or H 2 O 2 ), bases (NaOH or KOH), and acids [HCl or HNO 3 ; concentrated and diluted (5%)] in digesting fish tissues at room temperature (RT, 25°C), 40, 50, or 60°C. In the second phase, the treatments that were efficient in digesting the biological materials (>95%) were evaluated for their compatibility with eight major plastic polymers (assessed through recovery rate, Raman spectroscopy analysis, and morphological changes). Among the tested solutions, NaClO, NaOH, and diluted acids did not result in a satisfactory digestion efficiency at any of the temperatures. The H 2 O 2 treatment at 50°C efficiently digested the biological materials, although it decreased the recovery rate of nylon-6 (NY6) and nylon-66 (NY66) and altered the colour of polyethylene terephthalate (PET) fragments. Similarly, concentrated HCl and HNO 3 treatments at RT fully digested the fish tissues, but also fully dissolved NY6 and NY66, and reduced the recovery rate of most or all of the polymers, respectively. Potassium hydroxide solution fully eliminated the biological matrices at all temperatures. However, at 50 and 60°C, it degraded PET, reduced the recovery rate of PET and polyvinyl chloride (PVC), and changed the colour of NY66. According to our results, treating biological materials with a 10% KOH solution and incubating at 40°C was both time and cost-effective, efficient in digesting biological materials, and had no impact on the integrity of the plastic polymers. Furthermore, coupling this treatment with NaI extraction created a promising protocol to isolate MPs from whole fish samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Pan-European seasonal trends and recent changes of drought frequency and severity

    NASA Astrophysics Data System (ADS)

    Spinoni, Jonathan; Naumann, Gustavo; Vogt, Jürgen V.

    2017-01-01

    In the last decades drought has become one of the natural disasters with most relevant impacts in Europe and this not only in water scarce areas such as the Mediterranean that are inclined to such events. As a complex natural phenomenon, drought is characterized by many hydro-meteorological aspects, a large variety of possible impacts and definitions. This study focuses on meteorological drought, investigated by using indicators that include precipitation and potential evapotranspiration (PET), i.e. the Standardized Precipitation Index (SPI) and the Standardized Precipitation-Evapotranspiration Index (SPEI). These indicators account for the lack of precipitation and the drying effects of hot temperatures and in this study have been computed for short-accumulation periods (3-month) to capture the seasonality of droughts. The input variables, monthly precipitation and temperature for 1950-2015, stem from daily gridded E-OBS data and indicators were computed on regular grids spanning over the whole of Europe. PET was calculated from minimum and maximum temperatures using the Hargreaves-Samani formulation. Monthly precipitation and PET have then been used to compute the SPI-3 and the SPEI-3 time series. From these series drought events were defined at seasonal scale and trends of frequency and severity of droughts and extreme droughts were analyzed for the periods 1950-2015 and 1981-2015. According to the SPI (driven by precipitation), results show a statistically significant tendency towards less frequent and severe drought events over North-Eastern Europe, especially in winter and spring, and a moderate opposite tendency over Southern Europe, especially in spring and summer. According to the SPEI (driven by precipitation and temperature), Northern Europe shows similar wetting patterns, while Southern and Eastern Europe show a more remarkable drying tendency, especially in summer and autumn. Both for frequency and severity, the evolution towards drier conditions is more relevant in the last three decades over Central Europe in spring, the Mediterranean area in summer, and Eastern Europe in autumn.

  19. Exploring the Appropriate Drought Index in a Humid Tropical Area with Complex Terrain

    NASA Astrophysics Data System (ADS)

    Lee, C. H.; Chen, W. T.; Lo, M. H.; Chu, J. L.; Chen, Y. J.; Chen, Y. M.

    2017-12-01

    The goal of the present study is to identify the most appropriate index to monitor droughts in Taiwan, an extremely humid region with steep terrain. Three drought indices were calculated using in situ high resolution rainfall observations and compared: the Standardized Precipitation Index (SPI), the self-calibrating Palmer Drought Severity Index (sc-PDSI), and the Standardized Precipitation Evapotranspiration Index (SPEI). In Taiwan, the average amount of precipitation is around 2500 mm per year, which is six times of the global average. However, with the complexity of topography and the uneven distribution throughout the year in Taiwan, abundant rainfall during the wet season is mostly lost as runoff. Severe droughts occur frequently at approximately once per decade, while moderate droughts occur every 2 years. Earlier studies indicated that the SPI is limited in describing drought events because the temperature effect is not taken into account in SPI as in the sc-PDSI. In addition, SPEI, which take the Penman-Monteith Potential Evapotranspiration (PET_pm) into account, is also considered in the present study. The atmospheric water demand increases as temperature increasing, which is reflected in PET_pm. To calculate the three drought indices, we will use the monthly average temperature to calculate the PET_pm and monthly accumulated precipitation from automatic weather stations from the Central Weather Bureau. All of the detected droughts are evaluated against the dataset of historical drought records in Taiwan. We explore whether the temperature is an important factor for the occurrence of droughts in Taiwan first. In addition to severe droughts, we expect that SPEI and sc-PDSI can detect more moderate droughts in Taiwan. Second, we survey the performance of three drought indices for the detection of droughts in Taiwan. Because the soil water model used in sc-PDSI doesn't consider the effect of steep terrain, and because SPI only considers the monthly precipitation, we expect SPEI to be the more appropriate index for monitoring drought events in Taiwan.

  20. Cyclic versus Noncyclic Chelating Scaffold for 89Zr-Labeled ZEGFR:2377 Affibody Bioconjugates Targeting Epidermal Growth Factor Receptor Overexpression

    PubMed Central

    2017-01-01

    Zirconium-89 is an emerging radionuclide for positron emission tomography (PET) especially for biomolecules with slow pharmacokinetics as due to its longer half-life, in comparison to fluorine-18 and gallium-68, imaging at late time points is feasible. Desferrioxamine B (DFO), a linear bifunctional chelator (BFC) is mostly used for this radionuclide so far but shows limitations regarding stability. Our group recently reported on fusarinine C (FSC) with similar zirconium-89 complexing properties but potentially higher stability related to its cyclic structure. This study was designed to compare FSC and DFO head-to-head as bifunctional chelators for 89Zr-radiolabeled EGFR-targeting ZEGFR:2377 affibody bioconjugates. FSC-ZEGFR:2377 and DFO-ZEGFR:2377 were evaluated regarding radiolabeling, in vitro stability, specificity, cell uptake, receptor affinity, biodistribution, and microPET-CT imaging. Both conjugates were efficiently labeled with zirconium-89 at room temperature but radiochemical yields increased substantially at elevated temperature, 85 °C. Both 89Zr-FSC-ZEGFR:2377 and 89Zr-DFO-ZEGFR:2377 revealed remarkable specificity, affinity and slow cell-line dependent internalization. Radiolabeling at 85 °C showed comparable results in A431 tumor xenografted mice with minor differences regarding blood clearance, tumor and liver uptake. In comparison 89Zr-DFO-ZEGFR:2377, radiolabeled at room temperature, showed a significant difference regarding tumor-to-organ ratios. MicroPET-CT imaging studies of 89Zr-FSC-ZEGFR:2377 as well as 89Zr-DFO-ZEGFR:2377 confirmed these findings. In summary we were able to show that FSC is a suitable alternative to DFO for radiolabeling of biomolecules with zirconium-89. Furthermore, our findings indicate that 89Zr-radiolabeling of DFO conjugates at higher temperature reduces off-chelate binding leading to significantly improved tumor-to-organ ratios and therefore enhancing image contrast. PMID:29160082

  1. BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET

    NASA Astrophysics Data System (ADS)

    Brunner, S. E.; Schaart, D. R.

    2017-06-01

    Due to detector developments in the last decade, the time-of-flight (TOF) method is now commonly used to improve the quality of positron emission tomography (PET) images. Clinical TOF-PET systems based on L(Y)SO:Ce crystals and silicon photomultipliers (SiPMs) with coincidence resolving times (CRT) between 325 ps and 400 ps FWHM have recently been developed. Before the introduction of L(Y)SO:Ce, BGO was used in many PET systems. In addition to a lower price, BGO offers a superior attenuation coefficient and a higher photoelectric fraction than L(Y)SO:Ce. However, BGO is generally considered an inferior TOF-PET scintillator. In recent years, TOF-PET detectors based on the Cherenkov effect have been proposed. However, the low Cherenkov photon yield in the order of  ˜10 photons per event complicates energy discrimination-a severe disadvantage in clinical PET. The optical characteristics of BGO, in particular its high transparency down to 310 nm and its high refractive index of  ˜2.15, are expected to make it a good Cherenkov radiator. Here, we study the feasibility of combining event timing based on Cherenkov emission with energy discrimination based on scintillation in BGO, as a potential approach towards a cost-effective TOF-PET detector. Rise time measurements were performed using a time-correlated single photon counting (TCSPC) setup implemented on a digital photon counter (DPC) array, revealing a prompt luminescent component likely to be due to Cherenkov emission. Coincidence timing measurements were performed using BGO crystals with a cross-section of 3 mm  ×  3 mm and five different lengths between 3 mm and 20 mm, coupled to DPC arrays. Non-Gaussian coincidence spectra with a FWHM of 200 ps were obtained with the 27 mm3 BGO cubes, while FWHM values as good as 330 ps were achieved with the 20 mm long crystals. The FWHM value was found to improve with decreasing temperature, while the FWTM value showed the opposite trend.

  2. BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET.

    PubMed

    Brunner, S E; Schaart, D R

    2017-06-07

    Due to detector developments in the last decade, the time-of-flight (TOF) method is now commonly used to improve the quality of positron emission tomography (PET) images. Clinical TOF-PET systems based on L(Y)SO:Ce crystals and silicon photomultipliers (SiPMs) with coincidence resolving times (CRT) between 325 ps and 400 ps FWHM have recently been developed. Before the introduction of L(Y)SO:Ce, BGO was used in many PET systems. In addition to a lower price, BGO offers a superior attenuation coefficient and a higher photoelectric fraction than L(Y)SO:Ce. However, BGO is generally considered an inferior TOF-PET scintillator. In recent years, TOF-PET detectors based on the Cherenkov effect have been proposed. However, the low Cherenkov photon yield in the order of  ∼10 photons per event complicates energy discrimination-a severe disadvantage in clinical PET. The optical characteristics of BGO, in particular its high transparency down to 310 nm and its high refractive index of  ∼2.15, are expected to make it a good Cherenkov radiator. Here, we study the feasibility of combining event timing based on Cherenkov emission with energy discrimination based on scintillation in BGO, as a potential approach towards a cost-effective TOF-PET detector. Rise time measurements were performed using a time-correlated single photon counting (TCSPC) setup implemented on a digital photon counter (DPC) array, revealing a prompt luminescent component likely to be due to Cherenkov emission. Coincidence timing measurements were performed using BGO crystals with a cross-section of 3 mm  ×  3 mm and five different lengths between 3 mm and 20 mm, coupled to DPC arrays. Non-Gaussian coincidence spectra with a FWHM of 200 ps were obtained with the 27 mm 3 BGO cubes, while FWHM values as good as 330 ps were achieved with the 20 mm long crystals. The FWHM value was found to improve with decreasing temperature, while the FWTM value showed the opposite trend.

  3. Preparation of activated carbon from waste plastics polyethylene terephthalate as adsorbent in natural gas storage

    NASA Astrophysics Data System (ADS)

    Yuliusman; Nasruddin; Sanal, A.; Bernama, A.; Haris, F.; Ramadhan, I. T.

    2017-02-01

    The main problem is the process of natural gas storage and distribution, because in normal conditions of natural gas in the gas phase causes the storage capacity be small and efficient to use. The technology is commonly used Compressed Natural Gas (CNG) and Liquefied Natural Gas (LNG). The weakness of this technology safety level is low because the requirement for high-pressure CNG (250 bar) and LNG requires a low temperature (-161°C). It takes innovation in the storage of natural gas using the technology ANG (Adsorbed Natural Gas) with activated carbon as an adsorbent, causing natural gas can be stored in a low pressure of about 34.5. In this research, preparation of activated carbon using waste plastic polyethylene terephthalate (PET). PET plastic waste is a good raw material for making activated carbon because of its availability and the price is a lot cheaper. Besides plastic PET has the appropriate characteristics as activated carbon raw material required for the storage of natural gas because the material is hard and has a high carbon content of about 62.5% wt. The process of making activated carbon done is carbonized at a temperature of 400 ° C and physical activation using CO2 gas at a temperature of 975 ° C. The parameters varied in the activation process is the flow rate of carbon dioxide and activation time. The results obtained in the carbonization process yield of 21.47%, while the yield on the activation process by 62%. At the optimum process conditions, the CO2 flow rate of 200 ml/min and the activation time of 240 minutes, the value % burn off amounted to 86.69% and a surface area of 1591.72 m2/g.

  4. Polyimide Prepregs With Improved Tack

    NASA Technical Reports Server (NTRS)

    Vanucci, R.

    1987-01-01

    Drape and tack improved without loss of strength. Composites made with PMR-15 (or equivalent) polyimides have gained acceptance as viable engineering materials for high-use-temperature applications. Acceptance due to both thermo-oxidative stability of PMR-15 (or equivalent) and ease which PMR-15 (or equivalent) prepreg materials processed into composite structures.

  5. Synthesis of poly(ethylene furandicarboxylate) polyester using monomers derived from renewable resources: thermal behavior comparison with PET and PEN.

    PubMed

    Papageorgiou, George Z; Tsanaktsis, Vasilios; Bikiaris, Dimitrios N

    2014-05-07

    Poly(ethylene-2,5-furandicarboxylate) (PEF) is a new alipharomatic polyester that can be prepared from monomers derived from renewable resources like furfural and hydroxymethylfurfural. For this reason it has gained high interest recently. In the present work it was synthesized from the dimethylester of 2,5-furandicarboxylic acid and ethylene glycol by applying the two-stage melt polycondensation method. The thermal behavior of PEF was studied in comparison to its terephthalate and naphthalate homologues poly(ethylene terephthalate) (PET) and poly(ethylene naphthalate) (PEN), which were also synthesized following the same procedure. The equilibrium melting point of PEF was found to be 265 °C while the heat of fusion for the pure crystalline PEF was estimated to be about 137 J g(-1). The crystallization kinetics was analyzed using various models. PET showed faster crystallization rates than PEN and this in turn showed faster crystallization than PEF, under both isothermal and non-isothermal conditions. The spherulitic morphology of PEF during isothermal crystallization was investigated by polarized light microscopy (PLM). A large nucleation density and a small spherulite size were observed for PEF even at low supercoolings, in contrast to PET or PEN. Thermogravimetric analysis indicated that PEF is thermally stable up to 325 °C and the temperature for the maximum degradation rate was 438 °C. These values were a little lower than those for PET or PEN.

  6. SU-F-I-55: Performance Evaluation of Digital PET/CT: Medical Physics Basis for the Clinical Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Knopp, MV; Miller, M

    2016-06-15

    Purpose: Replacement of conventional PMT-based detector with next generation digital photon counting (DPC) detector is a technology leap for PET imaging. This study evaluated the performance and characteristics of the DPC system and its stability within a 1 year time window following its installation focusing on the medical physics basis for clinical applications. Methods: A digital PET/CT scanner using 1:1 coupling of 23,040 crystal: detector elements was introduced and became operational at OSU. We tested and evaluated system performance and characteristics using NEMA NU2-2012. System stabilities in timing resolution, energy resolution, detector temperature and humidity (T&H) were monitored over 1-yr.more » Timing, energy and spatial resolution were characterized across clinically relevant count rate range. CQIE uniformity PET and NEMA IEC-Body PET with hot spheres varying with sizes and contrasts were performed. PET reconstructed in standard(4mm), High(2mm) and Ultra-High(1mm) definitions were evaluated. Results: NEMA results showed PET spatial resolution (mm-FWHM) from 4.01&4.14 at 1cm to 5.82&6.17 at 20cm in transverse & axial. 322±3ps timing and 11.0% energy resolution were measured. 5.7kcps/MBq system sensitivity with 24kcps/MBq effective sensitivity was obtained. The peak-NECR was ∼171kcps with the effective peak-NECR >650kcps@50kBq/mL. Scatter fraction was ∼30%, and the maximum trues was >900kcps. NEMA IQ demonstrated hot sphere contrast ranging from ∼62%±2%(10mm) to ∼88%±2%(22mm), cold sphere contrast of ∼86%±2%(28mm) and ∼89%±3%(37mm) and excellent uniformity. Monitoring 1-yr stability, it revealed ∼1% change in timing, ±0.4% change in energy resolution, and <10% variations in T&H. CQIE PET gave <3% SUV variances in axial. 60%–100% recovery coefficients across sphere sizes and contrast levels were achieved. Conclusion: Characteristics and stability of the next generation DPC PET detector system over an 1-yr time window was excellent and better than prior experiences. It demonstrated improved and robust system characteristics and performance in spatial resolution, sensitivity, timing and energy resolution, count rate and image quality. Michael Miller is an employee of Philips Healthcare.« less

  7. NEMA NU-04-based performance characteristics of the LabPET-8™ small animal PET scanner.

    PubMed

    Prasad, Rameshwar; Ratib, Osman; Zaidi, Habib

    2011-10-21

    The objective of this study is to characterize the performance of the preclinical avalanche photodiode (APD)-based LabPET-8™ subsystem of the fully integrated trimodality PET/SPECT/CT Triumph™ scanner using the National Electrical Manufacturers Association (NEMA) NU 04-2008 protocol. The characterized performance parameters include the spatial resolution, sensitivity, scatter fraction, counts rate performance and image-quality characteristics. The PET system is fully digital using APD-based detector modules with highly integrated electronics. The detector assembly consists of phoswich pairs of Lu(1.9)Y(0.1)SiO(5) (LYSO) and Lu(0.4)Gd(1.6)SiO(5) (LGSO) crystals with dimensions of 2 × 2 × 14 mm(3) having 7.5 cm axial and 10 cm transverse field of view (FOV). The spatial resolution and sensitivity were measured using a small (22)Na point source at different positions in the scanner's FOV. The scatter fraction and count rate characteristics were measured using mouse- and rat-sized phantoms fitted with an (18)F line source. The overall imaging capabilities of the scanner were assessed using the NEMA image-quality phantom and laboratory animal studies. The NEMA-based radial and tangential spatial resolution ranged from 1.7 mm at the center of the FOV to 2.59 mm at a radial offset of 2.5 cm and from 1.85 mm at the center of the FOV to 1.76 mm at a radial offset of 2.5 cm, respectively. Iterative reconstruction improved the spatial resolution to 0.84 mm at the center of the FOV. The total absolute system sensitivity is 12.74% for an energy window of 250-650 keV. For the mouse-sized phantom, the peak noise equivalent count rate (NECR) is 183 kcps at 2.07 MBq cc(-1), whereas the peak true count rate is 320 kcps at 2.5 MBq cc(-1) with a scatter fraction of 19%. The rat-sized phantom had a scatter fraction of 31%, with a peak NECR of 67 kcps at 0.23 MBq cc(-1) and a peak true count rate of 186 kcps at 0.27 MBq cc(-1). The average activity concentration and percentage standard deviation were 126.97 kBq ml(-1) and 7%, respectively. The performance of the LabPET-8™ scanner was characterized based on the NEMA NU 04-2008 standards. The all in all performance demonstrates that the LabPET-8™ system is able to produce high-quality and highly contrasted images in a reasonable time, and as such it is well suited for preclinical molecular imaging-based research.

  8. NEMA NU-04-based performance characteristics of the LabPET-8™ small animal PET scanner

    NASA Astrophysics Data System (ADS)

    Prasad, Rameshwar; Ratib, Osman; Zaidi, Habib

    2011-10-01

    The objective of this study is to characterize the performance of the preclinical avalanche photodiode (APD)-based LabPET-8™ subsystem of the fully integrated trimodality PET/SPECT/CT Triumph™ scanner using the National Electrical Manufacturers Association (NEMA) NU 04-2008 protocol. The characterized performance parameters include the spatial resolution, sensitivity, scatter fraction, counts rate performance and image-quality characteristics. The PET system is fully digital using APD-based detector modules with highly integrated electronics. The detector assembly consists of phoswich pairs of Lu1.9Y0.1SiO5 (LYSO) and Lu0.4Gd1.6SiO5 (LGSO) crystals with dimensions of 2 × 2 × 14 mm3 having 7.5 cm axial and 10 cm transverse field of view (FOV). The spatial resolution and sensitivity were measured using a small 22Na point source at different positions in the scanner's FOV. The scatter fraction and count rate characteristics were measured using mouse- and rat-sized phantoms fitted with an18F line source. The overall imaging capabilities of the scanner were assessed using the NEMA image-quality phantom and laboratory animal studies. The NEMA-based radial and tangential spatial resolution ranged from 1.7 mm at the center of the FOV to 2.59 mm at a radial offset of 2.5 cm and from 1.85 mm at the center of the FOV to 1.76 mm at a radial offset of 2.5 cm, respectively. Iterative reconstruction improved the spatial resolution to 0.84 mm at the center of the FOV. The total absolute system sensitivity is 12.74% for an energy window of 250-650 keV. For the mouse-sized phantom, the peak noise equivalent count rate (NECR) is 183 kcps at 2.07 MBq cc-1, whereas the peak true count rate is 320 kcps at 2.5 MBq cc-1 with a scatter fraction of 19%. The rat-sized phantom had a scatter fraction of 31%, with a peak NECR of 67 kcps at 0.23 MBq cc-1 and a peak true count rate of 186 kcps at 0.27 MBq cc-1. The average activity concentration and percentage standard deviation were 126.97 kBq ml-1 and 7%, respectively. The performance of the LabPET-8™ scanner was characterized based on the NEMA NU 04-2008 standards. The all in all performance demonstrates that the LabPET-8™ system is able to produce high-quality and highly contrasted images in a reasonable time, and as such it is well suited for preclinical molecular imaging-based research.

  9. The role of the equivalent blackbody temperature in the study of Atlantic Ocean tropical cyclones

    NASA Technical Reports Server (NTRS)

    Steranka, J.; Rodgers, E. B.; Gentry, R. C.

    1983-01-01

    Satellite measured equivalent blackbody temperatures of Atlantic Ocean tropical cyclones are used to investigate their role in describing the convection and cloud patterns of the storms and in predicting wind intensity. The high temporal resolution of the equivalent blackbody temperature measurements afforded with the geosynchronous satellite provided sequential quantitative measurements of the tropical cyclone which reveal a diurnal pattern of convection at the inner core during the early developmental stage; a diurnal pattern of cloudiness in the storm's outer circulation throughout the life cycle; a semidiurnal pattern of cloudiness in the environmental atmosphere surrounding the storms during the weak storm stage; an outward modulating atmospheric wave originating at the inner core; and long term convective bursts at the inner core prior to wind intensification.

  10. An Investigation into the Effects of Temperature and Storage Time on Military Packaged Water in Afghanistan - The Liberation and Migration of Potential Contaminants from Expeditionary Water Packaging System Polyethylene Terephthalate Water Bottles

    DTIC Science & Technology

    2012-03-29

    PET   bottle   degradation   due   to   storage   at   elevated   temperatures.   Results   have   direct... bottle   degradation   of   chemical   and   aesthetic   drinking   water   characteristics   with   extended   storage  at...elevated  temperatures.  To  elucidate  the  impact  of   bottled  water  storage  practices

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Causa, Andrea; Acierno, Domenico; Filippone, Giovanni

    We prepare and characterize multiphase systems in which small amounts of recycled polymer, namely polyethylene terephtalate (PET) ground from waste bottles, are dispersed in a co-continuous blend of high-density polyethylene (HDPE) and polypropylene (PP). Some of such ternary systems are also filled with plate-like clay nanoparticles with different polarities, in order to assess their influence on the morphology and mechanical behaviour of the blends. On the basis of preliminary wettability considerations and inspections by means of scanning electron microscopy (SEM), the PET is found to preferentially locate within the PP phase. Such a positioning is desirable in order to minimizemore » the presence of multiple interfaces, which is one of the major issues in the recycling process of co-mingles plastics. By means of SEM, dynamic-mechanical analysis and tensile tests we show that the addition of a filler with low polarity, which locates at the PET-matrix interface, has relevant implications on the structure and properties of the ternary systems, refining their morphology at the micro-scale and enhancing their high-temperature mechanical behaviour.« less

  12. Current and temperature distributions in-situ acquired by electrode-segmentation along a microtubular solid oxide fuel cell operating with syngas

    NASA Astrophysics Data System (ADS)

    Aydın, Özgür; Nakajima, Hironori; Kitahara, Tatsumi

    2015-10-01

    Addressing the fuel distribution and endothermic cooling by the internal reforming, we have measured longitudinal current/temperature variations by ;Electrode-segmentation; in a microtubular solid oxide fuel cell operated with syngas (50% pre-reformed methane) and equivalent H2/N2 (100% conversion of syngas to H2) at three different flow rates. Regardless of the syngas flow rates, currents and temperatures show irregular fluctuations with varying amplitudes from upstream to downstream segment. Analysis of the fluctuations suggests that the methane steam reforming reaction is highly affected by the H2 partial pressure. Current-voltage curves plotted for the syngas and equivalent H2/N2 flow rates reveal that the fuel depletion is enhanced toward the downstream during the syngas operation, resulting in a larger performance degradation. All the segments exhibit temperature drops with the syngas flow compared with the equivalent H2/N2 flow due to the endothermic cooling by the methane steam reforming reaction. Despite the drops, the segment temperatures remain above the furnace temperature; besides, the maximum temperature difference along the cell diminishes. The MSR reaction rate does not consistently increase with the decreasing gas inlet velocity (increasing residence time on the catalyst); which we ascribe to the dominating impact of the local temperatures.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bordival, M.; Schmidt, F. M.; Le Maoult, Y.

    In the Stretch-Blow Molding (SBM) process, the temperature distribution of the reheated perform affects drastically the blowing kinematic, the bottle thickness distribution, as well as the orientation induced by stretching. Consequently, mechanical and optical properties of the final bottle are closely related to heating conditions. In order to predict the 3D temperature distribution of a rotating preform, numerical software using control-volume method has been developed. Since PET behaves like a semi-transparent medium, the radiative flux absorption was computed using Beer Lambert law. In a second step, 2D axi-symmetric simulations of the SBM have been developed using the finite element packagemore » ABAQUS registered . Temperature profiles through the preform wall thickness and along its length were computed and applied as initial condition. Air pressure inside the preform was not considered as an input variable, but was automatically computed using a thermodynamic model. The heat transfer coefficient applied between the mold and the polymer was also measured. Finally, the G'sell law was used for modeling PET behavior. For both heating and blowing stage simulations, a good agreement has been observed with experimental measurements. This work is part of the European project ''APT{sub P}ACK'' (Advanced knowledge of Polymer deformation for Tomorrow's PACKaging)« less

  14. Quantifying the Combined Effect of Radiation Therapy and Hyperthermia in Terms of Equivalent Dose Distributions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kok, H. Petra, E-mail: H.P.Kok@amc.uva.nl; Crezee, Johannes; Franken, Nicolaas A.P.

    2014-03-01

    Purpose: To develop a method to quantify the therapeutic effect of radiosensitization by hyperthermia; to this end, a numerical method was proposed to convert radiation therapy dose distributions with hyperthermia to equivalent dose distributions without hyperthermia. Methods and Materials: Clinical intensity modulated radiation therapy plans were created for 15 prostate cancer cases. To simulate a clinically relevant heterogeneous temperature distribution, hyperthermia treatment planning was performed for heating with the AMC-8 system. The temperature-dependent parameters α (Gy{sup −1}) and β (Gy{sup −2}) of the linear–quadratic model for prostate cancer were estimated from the literature. No thermal enhancement was assumed for normalmore » tissue. The intensity modulated radiation therapy plans and temperature distributions were exported to our in-house-developed radiation therapy treatment planning system, APlan, and equivalent dose distributions without hyperthermia were calculated voxel by voxel using the linear–quadratic model. Results: The planned average tumor temperatures T90, T50, and T10 in the planning target volume were 40.5°C, 41.6°C, and 42.4°C, respectively. The planned minimum, mean, and maximum radiation therapy doses were 62.9 Gy, 76.0 Gy, and 81.0 Gy, respectively. Adding hyperthermia yielded an equivalent dose distribution with an extended 95% isodose level. The equivalent minimum, mean, and maximum doses reflecting the radiosensitization by hyperthermia were 70.3 Gy, 86.3 Gy, and 93.6 Gy, respectively, for a linear increase of α with temperature. This can be considered similar to a dose escalation with a substantial increase in tumor control probability for high-risk prostate carcinoma. Conclusion: A model to quantify the effect of combined radiation therapy and hyperthermia in terms of equivalent dose distributions was presented. This model is particularly instructive to estimate the potential effects of interaction from different treatment modalities.« less

  15. Analytical evaluation of effect of equivalence ratio inlet-air temperature and combustion pressure on performance of several possible ram-jet fuels

    NASA Technical Reports Server (NTRS)

    Tower, Leonard K; Gammon, Benson E

    1953-01-01

    The results of an analytical investigation of the theoretical air specific impulse performance and adiabatic combustion temperatures of several possible ram-jet fuels over a range of equivalence ratios, inlet-air temperatures, and combustion pressures, is presented herein. The fuels include octane-1, 50-percent-magnesium slurry, boron, pentaborane, diborane, hydrogen, carbon, and aluminum. Thermal effects from high combustion temperatures were found to effect considerably the combustion performance of all the fuels. An increase in combustion pressure was beneficial to air specific impulse at high combustion temperatures. The use of these theoretical data in engine operation and in the evaluation of experimental data is described.

  16. Shot-noise in resistive-diode mixers and the attenuator noise model

    NASA Technical Reports Server (NTRS)

    Kerr, A. R.

    1979-01-01

    The representation of a pumped exponential diode, operating as a mixer, by an equivalent lossy network, is reexamined. It is shown that the model is correct provided the network has ports for all sideband frequencies at which (real) power flow can occur between the diode and its embedding. The temperature of the equivalent network is eta/2 times the physical temperature of the diode. The model is valid only if the series resistance and nonlinear capacitance of the diode are negligible. Expressions are derived for the input and output noise temperature and the noise-temperature ratio of ideal mixers. Some common beliefs concerning noise-figure and noise-temperature ratio are shown to be incorrect.

  17. A novel metric for quantification of homogeneous and heterogeneous tumors in PET for enhanced clinical outcome prediction

    NASA Astrophysics Data System (ADS)

    Rahmim, Arman; Schmidtlein, C. Ross; Jackson, Andrew; Sheikhbahaei, Sara; Marcus, Charles; Ashrafinia, Saeed; Soltani, Madjid; Subramaniam, Rathan M.

    2016-01-01

    Oncologic PET images provide valuable information that can enable enhanced prognosis of disease. Nonetheless, such information is simplified significantly in routine clinical assessment to meet workflow constraints. Examples of typical FDG PET metrics include: (i) SUVmax, (2) total lesion glycolysis (TLG), and (3) metabolic tumor volume (MTV). We have derived and implemented a novel metric for tumor quantification, inspired in essence by a model of generalized equivalent uniform dose as used in radiation therapy. The proposed metric, denoted generalized effective total uptake (gETU), is attractive as it encompasses the abovementioned commonly invoked metrics, and generalizes them, for both homogeneous and heterogeneous tumors, using a single parameter a. We evaluated this new metric for improved overall survival (OS) prediction on two different baseline FDG PET/CT datasets: (a) 113 patients with squamous cell cancer of the oropharynx, and (b) 72 patients with locally advanced pancreatic adenocarcinoma. Kaplan-Meier survival analysis was performed, where the subjects were subdivided into two groups using the median threshold, from which the hazard ratios (HR) were computed in Cox proportional hazards regression. For the oropharyngeal cancer dataset, MTV, TLG, SUVmax, SUVmean and SUVpeak produced HR values of 1.86, 3.02, 1.34, 1.36 and 1.62, while the proposed gETU metric for a  = 0.25 (greater emphasis on volume information) enabled significantly enhanced OS prediction with HR  =  3.94. For the pancreatic cancer dataset, MTV, TLG, SUVmax, SUVmean and SUVpeak resulted in HR values of 1.05, 1.25, 1.42, 1.45 and 1.52, while gETU at a  = 3.2 (greater emphasis on SUV information) arrived at an improved HR value of 1.61. Overall, the proposed methodology allows placement of differing degrees of emphasis on tumor volume versus uptake for different types of tumors to enable enhanced clinical outcome prediction.

  18. dAcquisition setting optimization and quantitative imaging for 124I studies with the Inveon microPET-CT system.

    PubMed

    Anizan, Nadège; Carlier, Thomas; Hindorf, Cecilia; Barbet, Jacques; Bardiès, Manuel

    2012-02-13

    Noninvasive multimodality imaging is essential for preclinical evaluation of the biodistribution and pharmacokinetics of radionuclide therapy and for monitoring tumor response. Imaging with nonstandard positron-emission tomography [PET] isotopes such as 124I is promising in that context but requires accurate activity quantification. The decay scheme of 124I implies an optimization of both acquisition settings and correction processing. The PET scanner investigated in this study was the Inveon PET/CT system dedicated to small animal imaging. The noise equivalent count rate [NECR], the scatter fraction [SF], and the gamma-prompt fraction [GF] were used to determine the best acquisition parameters for mouse- and rat-sized phantoms filled with 124I. An image-quality phantom as specified by the National Electrical Manufacturers Association NU 4-2008 protocol was acquired and reconstructed with two-dimensional filtered back projection, 2D ordered-subset expectation maximization [2DOSEM], and 3DOSEM with maximum a posteriori [3DOSEM/MAP] algorithms, with and without attenuation correction, scatter correction, and gamma-prompt correction (weighted uniform distribution subtraction). Optimal energy windows were established for the rat phantom (390 to 550 keV) and the mouse phantom (400 to 590 keV) by combining the NECR, SF, and GF results. The coincidence time window had no significant impact regarding the NECR curve variation. Activity concentration of 124I measured in the uniform region of an image-quality phantom was underestimated by 9.9% for the 3DOSEM/MAP algorithm with attenuation and scatter corrections, and by 23% with the gamma-prompt correction. Attenuation, scatter, and gamma-prompt corrections decreased the residual signal in the cold insert. The optimal energy windows were chosen with the NECR, SF, and GF evaluation. Nevertheless, an image quality and an activity quantification assessment were required to establish the most suitable reconstruction algorithm and corrections for 124I small animal imaging.

  19. Transmission imaging for integrated PET-MR systems.

    PubMed

    Bowen, Spencer L; Fuin, Niccolò; Levine, Michael A; Catana, Ciprian

    2016-08-07

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method's performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with (18)F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm(-1) was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly less artifacts and improved dynamic range, and differed greatly for highly attenuating materials in the case of the patient table, compared to CT results. Use of a fixed torus geometry, in combination with translation of the patient table to perform complete tomographic sampling, generated highly quantitative measured μ-maps and is expected to produce images with significantly higher SNR than competing fixed geometries at matched total acquisition time.

  20. Transmission imaging for integrated PET-MR systems

    NASA Astrophysics Data System (ADS)

    Bowen, Spencer L.; Fuin, Niccolò; Levine, Michael A.; Catana, Ciprian

    2016-08-01

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method’s performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with 18F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm-1 was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly less artifacts and improved dynamic range, and differed greatly for highly attenuating materials in the case of the patient table, compared to CT results. Use of a fixed torus geometry, in combination with translation of the patient table to perform complete tomographic sampling, generated highly quantitative measured μ-maps and is expected to produce images with significantly higher SNR than competing fixed geometries at matched total acquisition time.

  1. Characterization of heat transfer in nutrient materials, part 2

    NASA Technical Reports Server (NTRS)

    Cox, J. E.; Bannerot, R. B.; Chen, C. K.; Witte, L. C.

    1973-01-01

    A thermal model is analyzed that takes into account phase changes in the nutrient material. The behavior of fluids in low gravity environments is discussed along with low gravity heat transfer. Thermal contact resistance in the Skylab food heater is analyzed. The original model is modified to include: equivalent conductance due to radiation, radial equivalent conductance, wall equivalent conductance, and equivalent heat capacity. A constant wall-temperature model is presented.

  2. 18F-FDG PET/CT Equivalent of the Hepatic Hot Spot Sign With CT Correlation.

    PubMed

    Jundt, Michael C; Broski, Stephen M; Binkovitz, Larry A

    2018-05-01

    A 43-year-old woman presented with an FDG-avid mediastinal Ewing sarcoma invading and nearly occluding the superior vena cava. Geographic increased FDG uptake in hepatic segment IVA was the only other site of nonphysiologic FDG activity. This focal activity was without an underlying mass, had atypical morphology for a hepatic metastasis, and correlated well with prior CT findings of abnormal segment IVA enhancement resulting from the recruitment of portocaval collaterals. In the correct setting, the F-FDG hepatic hot spot should be considered in the differential of a focal FDG-avid hepatic lesion in segment IVA.

  3. Mechanical Equivalent of Heat--Software for a Thermistor

    ERIC Educational Resources Information Center

    Boleman, Michael

    2008-01-01

    The Mechanical Equivalent of Heat Apparatus from PASCO scientific provides the means for doing a simple experiment to determine the mechanical equivalent of heat, "J." A necessary step of this experiment is to determine the temperature of an aluminum cylinder. By measuring the resistance of a thermistor embedded in the cylinder, one is able to…

  4. Thermal Comfort Assessment in The Open Space in Bandung Case Study Dago Street and Riau Street

    NASA Astrophysics Data System (ADS)

    Sugangga, M.; Janesonia, K. I.; Illiyin, D. F.; Donny Koerniawan, M.

    2018-05-01

    Bandung’s temperature has been higher since last years. This phenomenon affects the level of thermal comfort in open space. One indicator that determines the thermal comfort level is the type of activity performed by the open space user. Riau Street and Dago Street are corridors that are often used by the people for strolling, jogging, shopping. Dago Street has special event every Sunday namely car free day. Both corridors have different orientation; Dago Street is North to South corridor while Riau Street’s is West to East. The goal of the study is to compare people’s perception of thermal comfort in both corridors. This research uses two methods, namely qualitative method and quantitative method. Based on the results of qualitative analysis found that the thermal conditions in Dago Street more comfortable than the Riau Street. The result of quantitative analysis found that the average PET (thermal comfort indices) value of Dago Street was at 27.5 °C PET and Riau Street 28.6 °C PET. Dago Street is considered more convenient because it has a lower PET value than Riau Street. The people perception of thermal comfort is very important to start the steps for designing the orientation of street in urban design.

  5. Laser short-pulse heating of an aluminum thin film: Energy transfer in electron and lattice sub-systems

    NASA Astrophysics Data System (ADS)

    Bin Mansoor, Saad; Sami Yilbas, Bekir

    2015-08-01

    Laser short-pulse heating of an aluminum thin film is considered and energy transfer in the film is formulated using the Boltzmann equation. Since the heating duration is short and the film thickness is considerably small, thermal separation of electron and lattice sub-systems is incorporated in the analysis. The electron-phonon coupling is used to formulate thermal communication of both sub-systems during the heating period. Equivalent equilibrium temperature is introduced to account for the average energy of all phonons around a local point when they redistribute adiabatically to an equilibrium state. Temperature predictions of the Boltzmann equation are compared with those obtained from the two-equation model. It is found that temperature predictions from the Boltzmann equation differ slightly from the two-equation model results. Temporal variation of equivalent equilibrium temperature does not follow the laser pulse intensity in the electron sub-system. The time occurrence of the peak equivalent equilibrium temperature differs for electron and lattice sub-systems, which is attributed to phonon scattering in the irradiated field in the lattice sub-system. In this case, time shift is observed for occurrence of the peak temperature in the lattice sub-system.

  6. Self-powered p-NiO/n-ZnO heterojunction ultraviolet photodetectors fabricated on plastic substrates

    PubMed Central

    Hasan, Md Rezaul; Xie, Ting; Barron, Sara C.; Liu, Guannan; Nguyen, Nhan V.; Motayed, Abhishek; Rao, Mulpuri V.; Debnath, Ratan

    2016-01-01

    A self-powered ultraviolet (UV) photodetector (PD) based on p-NiO and n-ZnO was fabricated using low-temperature sputtering technique on indium doped tin oxide (ITO) coated plastic polyethylene terephthalate (PET) substrates. The p-n heterojunction showed very fast temporal photoresponse with excellent quantum efficiency of over 63% under UV illumination at an applied reverse bias of 1.2 V. The engineered ultrathin Ti/Au top metal contacts and UV transparent PET/ITO substrates allowed the PDs to be illuminated through either front or back side. Morphology, structural, chemical and optical properties of sputtered NiO and ZnO films were also investigated. PMID:26900532

  7. Chemical scavenging of post-consumed clothes.

    PubMed

    Barot, Amit A; Sinha, Vijay Kumar

    2015-12-01

    Aiming toward the rectification of fiber grade PET waste accumulation as well as recycling and providing a technically viable route leading to preservation of the natural resources and environment, the post consumed polyester clothes were chemically recycled. Post consumed polyester clothes were recycled into bis(2-hydroxyethyl) terephthalate (BHET) monomer in the presence of ethylene glycol as depolymerising agent and zinc acetate as catalyst. Depolymerized product was characterized by chemical as well as analytical techniques. The fiber grade PET was eventually converted into BHET monomer with nearly 90% yield by employing 1% catalyst concentration and at optimum temperature of 180°C without mechanical input of stirring condition. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. 18F-FDG uptake in the colon is modulated by metformin but not associated with core body temperature and energy expenditure.

    PubMed

    Bahler, Lonneke; Holleman, Frits; Chan, Man-Wai; Booij, Jan; Hoekstra, Joost B; Verberne, Hein J

    2017-01-01

    Physiological colonic 18F-fluorodeoxyglucose (18F-FDG) uptake is a frequent finding on 18F-FDG positron emission tomography computed tomography (PET-CT). Interestingly, metformin, a glucose lowering drug associated with moderate weight loss, is also associated with an increased colonic 18F-FDG uptake. Consequently, increased colonic glucose use might partly explain the weight losing effect of metformin when this results in an increased energy expenditure and/or core body temperature. Therefore, we aimed to determine whether metformin modifies the metabolic activity of the colon by increasing glucose uptake. In this open label, non-randomized, prospective mechanistic study, we included eight lean and eight overweight males. We measured colonic 18F-FDG uptake on PET-CT, energy expenditure and core body temperature before and after the use of metformin. The maximal colonic 18F-FDG uptake was measured in 5 separate segments (caecum, colon ascendens,-transversum,-descendens and sigmoid). The maximal colonic 18F-FDG uptake increased significantly in all separate segments after the use of metformin. There was no significant difference in energy expenditure or core body temperature after the use of metformin. There was no correlation between maximal colonic 18F-FDG uptake and energy expenditure or core body temperature. Metformin significantly increases colonic 18F-FDG uptake, but this increased uptake is not associated with an increase in energy expenditure or core body temperature. Although the colon might be an important site of the glucose plasma lowering actions of metformin, this mechanism of action does not explain directly any associated weight loss.

  9. Direct absorption spectroscopy sensor for temperature and H2O concentration of flat flame burner

    NASA Astrophysics Data System (ADS)

    Duan, Jin-hu; Jin, Xing; Wang, Guang-yu; Qu, Dong-sheng

    2016-01-01

    A tunable diode laser absorption sensor, based on direct absorption spectroscopy and time division multiplexing scheme, was developed to measure H2O concentration and temperature of flat flame burner. At the height of 15mm from the furnace surface, temperature and concentration were measured at different equivalence ratios. Then the distance between the laser and the furnace surface was changed while the equivalence ratio was fixed at 1 and experiments were performed to measure temperature and H2O concentration at every height. At last flame temperatures and H2O concentrations were obtained by simulation and computational analysis and these combustion parameters were compared with the reference. The results showed that the experimental results were in accordance with the reference values. Temperature errors were less than 4% and H2O component concentration errors were less than 5%and both of them reached their maximum when the equivalent ratio was set at 1. The temperature and H2O concentration increased with the height from furnace surface to laser when it varied from 3mm to 9mm and it decreased when it varied from 9mm to 30mm and they reached their maximum at the height of 9mm. Keywords: tunable diode laser, direct absorption spectroscopy

  10. Evaluation, Calibration and Comparison of the Precipitation-Runoff Modeling System (PRMS) National Hydrologic Model (NHM) Using Moderate Resolution Imaging Spectroradiometer (MODIS) and Snow Data Assimilation System (SNODAS) Gridded Datasets

    NASA Astrophysics Data System (ADS)

    Norton, P. A., II; Haj, A. E., Jr.

    2014-12-01

    The United States Geological Survey is currently developing a National Hydrologic Model (NHM) to support and facilitate coordinated and consistent hydrologic modeling efforts at the scale of the continental United States. As part of this effort, the Geospatial Fabric (GF) for the NHM was created. The GF is a database that contains parameters derived from datasets that characterize the physical features of watersheds. The GF was used to aggregate catchments and flowlines defined in the National Hydrography Dataset Plus dataset for more than 100,000 hydrologic response units (HRUs), and to establish initial parameter values for input to the Precipitation-Runoff Modeling System (PRMS). Many parameter values are adjusted in PRMS using an automated calibration process. Using these adjusted parameter values, the PRMS model estimated variables such as evapotranspiration (ET), potential evapotranspiration (PET), snow-covered area (SCA), and snow water equivalent (SWE). In order to evaluate the effectiveness of parameter calibration, and model performance in general, several satellite-based Moderate Resolution Imaging Spectroradiometer (MODIS) and Snow Data Assimilation System (SNODAS) gridded datasets including ET, PET, SCA, and SWE were compared to PRMS-simulated values. The MODIS and SNODAS data were spatially averaged for each HRU, and compared to PRMS-simulated ET, PET, SCA, and SWE values for each HRU in the Upper Missouri River watershed. Default initial GF parameter values and PRMS calibration ranges were evaluated. Evaluation results, and the use of MODIS and SNODAS datasets to update GF parameter values and PRMS calibration ranges, are presented and discussed.

  11. A new method measuring the interaction of radiotracers with the human P-glycoprotein (P-gp) transporter.

    PubMed

    Vraka, Chrysoula; Dumanic, Monika; Racz, Teresa; Pichler, Florian; Philippe, Cecile; Balber, Theresa; Klebermass, Eva-Maria; Wagner, Karl-Heinz; Hacker, Marcus; Wadsak, Wolfgang; Mitterhauser, Markus

    2018-05-01

    In drug development, biomarkers for cerebral applications have a lower success rate compared to cardiovascular drugs or tumor therapeutics. One reason is the missing blood brain barrier penetration, caused by the tracer's interaction with efflux transporters such as the P-gp (MDR1 or ABCB1). Aim of this study was the development of a reliable model to measure the interaction of radiotracers with the human efflux transporter P-gp in parallel to the radiolabeling process. LigandTracer® Technology was used with the wildtype cell line MDCKII and the equivalent cell line overexpressing human P-gp (MDCKII-hMDR1). The method was evaluated based on established PET tracers with known interaction with the human P-gp transporter and in nanomolar concentration (15 nM). [ 11 C]SNAP-7941 and [ 18 F]FE@SNAP were used as P-gp substrates by comparing the real-time model with an uptake assay and μPET images. [ 11 C]DASB [ 11 C]Harmine, [ 18 F]FMeNER,[ 18 F]FE@SUPPY and [ 11 C]Me@HAPTHI were used as tracers without interactions with P-gp in vitro. However, [ 11 C]Me@HAPTHI shows a significant increase in SUV levels after blocking with Tariquidar. The developed real-time kinetic model uses directly PET tracers in a compound concentration, which is reflecting the in vivo situation. This method may be used at an early stage of radiopharmaceutical development to measure interactions to P-gp before conducting animal experiments. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Using Virtual Pets to Increase Fruit and Vegetable Consumption in Children: A Technology-Assisted Social Cognitive Theory Approach.

    PubMed

    Ahn, Sun Joo Grace; Johnsen, Kyle; Moore, James; Brown, Scott; Biersmith, Melanie; Ball, Catherine

    2016-02-01

    A virtual pet in the form of a mid-sized dog was developed based on the framework of social cognitive theory and tested as a vehicle for promoting fruit and vegetable (F&V) consumption in children. Three groups of children (N = 68) between the ages of 7 and 13 years were studied: baseline (no treatment), computer only, and virtual dog. Children in the virtual dog condition interacted with the virtual dog for 3 days, setting F&V consumption goals and receiving evaluation and reinforcement based on whether they met their self-set goals. Children vicariously experienced future health outcomes of F&V consumption by seeing, hearing, and feeling their virtual dog's physical and mental health improve or deteriorate based on their F&V consumption in the physical world. Children in the computer only condition interacted with a computer system that presented equivalent features, but without the virtual dog. Children in the baseline condition did not receive any experimental treatment. Results indicated that children in the virtual dog condition chose to be served significantly more F&V than those in the computer only or baseline conditions did. However, children in the virtual dog condition were unable to consume significantly more F&V than those in the computer only condition, although children in those two conditions consumed more F&V than the baseline condition. Food preferences did not differ significantly across the three conditions before and after the experimental treatments. Theoretical and practical potentials of using a virtual pet to promote F&V consumption systematically in children are discussed.

  13. Apathy in patients with Parkinson disease without dementia or depression: a PET study.

    PubMed

    Robert, Gabriel; Le Jeune, Florence; Lozachmeur, Clément; Drapier, Sophie; Dondaine, Thibault; Péron, Julie; Travers, David; Sauleau, Paul; Millet, Bruno; Vérin, Marc; Drapier, Dominique

    2012-09-11

    We sought to identify apathy metabolic bases in Parkinson disease (PD). A total of 45 patients with PD who were not clinically depressed (Montgomery-Åsberg Depression Rating Scale [MADRS] <21) and had no dementia (Mattis Dementia Rating Scale [MDRS] >130) were assessed with the Apathy Evaluation Scale (AES) and underwent a resting-state F-18 fluorodeoxyglucose PET (FDG-PET) scan. A motor assessment comprising the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III) was conducted and total levodopa equivalent daily dose (LEDD) was calculated. Imaging data were analyzed with statistical parametric mapping. Age, LEDD, and MDRS scores were introduced as covariates. Positive correlations were observed between the AES score and cerebral metabolism in the right inferior frontal gyrus (Brodmann area [BA] 47), right middle frontal gyrus (BA 10), right cuneus (BA 18), and right anterior insula (BA 13). Negative correlations were observed between the AES score and cerebellar metabolism in the semilunar lobules bilaterally, within the posterior lobe. Using an AES score equal to or above 42 to define clinical apathy, prevalence in our patient group was 17.8%. The AES score was negatively correlated with the MDRS score and positively correlated with the "retardation" subscore of the MADRS. It was not correlated with either UPDRS III or LEDD. Results indicate that the frontal, temporal, and cerebellar areas known to be involved in reward, emotion, and cognition are also implicated in apathy in patients with PD without dementia or depression. Their roles in the etiopathology of apathy are discussed.

  14. Timing performance of the silicon PET insert probe

    PubMed Central

    Studen, A.; Burdette, D.; Chesi, E.; Cindro, V.; Clinthorne, N. H.; Cochran, E.; Grošičar, B.; Kagan, H.; Lacasta, C.; Linhart, V.; Mikuž, M.; Stankova, V.; Weilhammer, P.; Žontar, D.

    2010-01-01

    Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 × 1 mm2 pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 256 square pads (1.4 mm side), coupled with two VATAGP7s, application-specific integrated circuits. The detector material and electronics are the same that will be used for the final probe. The model was exposed to 511 keV annihilation photons from an 22Na source, and a scintillator (LYSO)–PMT assembly was used as a timing reference. Results were compared with the simulation, consisting of four parts: (i) GEANT4 implemented realistic tracking of electrons excited by annihilation photon interactions in silicon, (ii) calculation of propagation of secondary ionisation (electron–hole pairs) in the sensor, (iii) estimation of the shape of the current pulse induced on surface electrodes and (iv) simulation of the first electronics stage. A very good agreement between the simulation and the measurements were found. Both indicate reliable performance of the final probe at timing windows down to 20 ns. PMID:20215445

  15. Timing performance of the silicon PET insert probe.

    PubMed

    Studen, A; Burdette, D; Chesi, E; Cindro, V; Clinthorne, N H; Cochran, E; Grosicar, B; Kagan, H; Lacasta, C; Linhart, V; Mikuz, M; Stankova, V; Weilhammer, P; Zontar, D

    2010-01-01

    Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 x 1 mm(2) pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 256 square pads (1.4 mm side), coupled with two VATAGP7s, application-specific integrated circuits. The detector material and electronics are the same that will be used for the final probe. The model was exposed to 511 keV annihilation photons from an (22)Na source, and a scintillator (LYSO)-PMT assembly was used as a timing reference. Results were compared with the simulation, consisting of four parts: (i) GEANT4 implemented realistic tracking of electrons excited by annihilation photon interactions in silicon, (ii) calculation of propagation of secondary ionisation (electron-hole pairs) in the sensor, (iii) estimation of the shape of the current pulse induced on surface electrodes and (iv) simulation of the first electronics stage. A very good agreement between the simulation and the measurements were found. Both indicate reliable performance of the final probe at timing windows down to 20 ns.

  16. Self-Organizing Map Neural Network-Based Nearest Neighbor Position Estimation Scheme for Continuous Crystal PET Detectors

    NASA Astrophysics Data System (ADS)

    Wang, Yonggang; Li, Deng; Lu, Xiaoming; Cheng, Xinyi; Wang, Liwei

    2014-10-01

    Continuous crystal-based positron emission tomography (PET) detectors could be an ideal alternative for current high-resolution pixelated PET detectors if the issues of high performance γ interaction position estimation and its real-time implementation are solved. Unfortunately, existing position estimators are not very feasible for implementation on field-programmable gate array (FPGA). In this paper, we propose a new self-organizing map neural network-based nearest neighbor (SOM-NN) positioning scheme aiming not only at providing high performance, but also at being realistic for FPGA implementation. Benefitting from the SOM feature mapping mechanism, the large set of input reference events at each calibration position is approximated by a small set of prototypes, and the computation of the nearest neighbor searching for unknown events is largely reduced. Using our experimental data, the scheme was evaluated, optimized and compared with the smoothed k-NN method. The spatial resolutions of full-width-at-half-maximum (FWHM) of both methods averaged over the center axis of the detector were obtained as 1.87 ±0.17 mm and 1.92 ±0.09 mm, respectively. The test results show that the SOM-NN scheme has an equivalent positioning performance with the smoothed k-NN method, but the amount of computation is only about one-tenth of the smoothed k-NN method. In addition, the algorithm structure of the SOM-NN scheme is more feasible for implementation on FPGA. It has the potential to realize real-time position estimation on an FPGA with a high-event processing throughput.

  17. Amino-functionalized sub-40 nm ultrathin Ag/ZnO transparent electrodes for flexible polymer dispersed liquid crystal devices

    NASA Astrophysics Data System (ADS)

    Huang, Jinhua; Lu, Yuehui; Wu, Wenxuan; Li, Jia; Zhang, Xianpeng; Zhu, Chaoting; Yang, Ye; Xu, Feng; Song, Weijie

    2017-11-01

    Various flexible transparent conducting electrodes (FTCEs) have been studied for promising applications in flexible optoelectronic devices, but there are still challenges in achieving higher transparency and conductivity, lower thickness, better mechanical flexibility, and lower preparation temperatures. In this work, we prepared a sub-40 nm Ag(9 nm)/ZnO(30 nm) FTCE at room temperature, where each layer played a relatively independent role in the tailoring of the optoelectronic properties. A continuous and smooth 9-nm Ag thin film was grown on amino-functionalized glass and polyethylene terephthalate (PET) substrates to provide good conductivity. A 30-nm ZnO cladding, as an antireflection layer, further improved the transmittance while hardly affecting the conductivity. The room-temperature grown sub-40 nm Ag/ZnO thin films on PET substrate exhibited a transmittance of 88.6% at 550 nm and a sheet resistance of 7.6 Ω.sq-1, which were superior to those of the commercial ITO. The facile preparation benefits the integration of FTCEs into various flexible optoelectronic devices, where the excellent performance of the sub-40 nm Ag/ZnO FTCEs in a flexible polymer dispersed liquid crystal device was demonstrated. Sub-40 nm Ag/ZnO FTCEs that have the characteristics of simple structure, room-temperature preparation, and easily tailored optoelectronic properties would provide flexible optoelectronic devices with more degrees of freedom.

  18. Clinical trials of the prototype Rutherford Appleton Laboratory MWPC positron camera at the Royal Marsden Hospital

    NASA Astrophysics Data System (ADS)

    Flower, M. A.; Ott, R. J.; Webb, S.; Leach, M. O.; Marsden, P. K.; Clack, R.; Khan, O.; Batty, V.; McCready, V. R.; Bateman, J. E.

    1988-06-01

    Two clinical trials of the prototype RAL multiwire proportional chamber (MWPC) positron camera were carried out prior to the development of a clinical system with large-area detectors. During the first clinical trial, the patient studies included skeletal imaging using 18F, imaging of brain glucose metabolism using 18F FDG, bone marrow imaging using 52Fe citrate and thyroid imaging with Na 124I. Longitudinal tomograms were produced from the limited-angle data acquisition from the static detectors. During the second clinical trial, transaxial, coronal and sagittal images were produced from the multiview data acquisition. A more detailed thyroid study was performed in which the volume of the functioning thyroid tissue was obtained from the 3D PET image and this volume was used in estimating the radiation dose achieved during radioiodine therapy of patients with thyrotoxicosis. Despite the small field of view of the prototype camera, and the use of smaller than usual amounts of activity administered, the PET images were in most cases comparable with, and in a few cases visually better than, the equivalent planar view using a state-of-the-art gamma camera with a large field of view and routine radiopharmaceuticals.

  19. Emissions from small-scale burns of simulated deployed U.S. military waste.

    PubMed

    Woodall, Brian D; Yamamoto, Dirk P; Gullett, Brian K; Touati, Abderrahmane

    2012-10-16

    U.S. military forces have historically relied on open burning as an expedient method of volume reduction and treatment of solid waste during the conflicts in Afghanistan and Iraq. This study is the first effort to characterize a broad range of pollutants and their emission factors during the burning of military waste and the effects that recycling efforts, namely removing plastics, might have on emissions. Piles of simulated military waste were constructed, burned, and emissions sampled at the U.S. Environmental Protection Agency (EPA) Open Burn Testing Facility (OBTF), Research Triangle Park, NC. Three tests contained polyethylene terephthalate (PET #1 or PET) plastic water bottles and four did not. Emission factors for polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs), particulate matter (PM(10), PM(2.5)), polychlorinated and polybrominated dioxins/furans (PCDD/F and PBDD/F), and criteria pollutants were determined and are contained within. The average PCDD/F emission factors were 270 ng-toxic equivalency (TEQ) per kg carbon burned (ng-TEQ/kg Cb), ranging from 35 to 780 ng-TEQ/kg Cb. Limited testing suggests that targeted removal of plastic water bottles has no apparent effect on reducing pollutants and may even promote increased emissions.

  20. Fast, Accurate and Shift-Varying Line Projections for Iterative Reconstruction Using the GPU

    PubMed Central

    Pratx, Guillem; Chinn, Garry; Olcott, Peter D.; Levin, Craig S.

    2013-01-01

    List-mode processing provides an efficient way to deal with sparse projections in iterative image reconstruction for emission tomography. An issue often reported is the tremendous amount of computation required by such algorithm. Each recorded event requires several back- and forward line projections. We investigated the use of the programmable graphics processing unit (GPU) to accelerate the line-projection operations and implement fully-3D list-mode ordered-subsets expectation-maximization for positron emission tomography (PET). We designed a reconstruction approach that incorporates resolution kernels, which model the spatially-varying physical processes associated with photon emission, transport and detection. Our development is particularly suitable for applications where the projection data is sparse, such as high-resolution, dynamic, and time-of-flight PET reconstruction. The GPU approach runs more than 50 times faster than an equivalent CPU implementation while image quality and accuracy are virtually identical. This paper describes in details how the GPU can be used to accelerate the line projection operations, even when the lines-of-response have arbitrary endpoint locations and shift-varying resolution kernels are used. A quantitative evaluation is included to validate the correctness of this new approach. PMID:19244015

  1. Novel cellulose-based halochromic test strips for naked-eye detection of alkaline vapors and analytes.

    PubMed

    Abou-Yousef, Hussein; Khattab, Tawfik A; Youssef, Yehia A; Al-Balakocy, Naser; Kamel, Samir

    2017-08-01

    A simple, portable and highly sensitive naked-eye test strip is successfully prepared for optical detection of gaseous and aqueous alkaline analytes. Novel pH-sensory tricyanofuran-hydrazone (TCFH) disperse colorant containing a hydrazone recognition functional moiety is successfully synthesized via azo-coupling reaction between active methyl-containing tricyanofuran (TCF) heterocycle and diazonium salt of 4-aminobenzaldehyde followed by Knoevenagel condensation with malononitrile. UV-vis absorption spectra display solvatochromism and reversible color changes of the TCFH solution in dimethyl sulfoxide in response to pH variations. We investigate the preparation of hydrophobic cellulose/polyethylene terephthalate composites characterized by their high affinity for disperse dyes. Composite films made from CA, Cell/CA, PET/CA, and Cell/PET-CA are produced via solvent-casting procedure using 10-30% modified cellulose or modified polyethylene terephthalate. The mechanical properties and morphologies of these composite films are investigated. The prepared pH-sensory hydrazone-based disperse dye is then applied to dye the produced cellulose-based composite films employing the high temperature pressure dyeing procedure. The produced halochromic PET-CA-TCFH test strip provide an instant visible signal from orange to purple upon exposure to alkaline conditions as proved by the coloration measurements. The sensor strip exhibits high sensitivity and quick detection toward ammonia in both of aqueous and vapor phases by naked-eye observations at room temperature and atmospheric pressure. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Sensitivity of the projected hydroclimatic environment of the Delaware River basin to formulation of potential evapotranspiration

    USGS Publications Warehouse

    Williamson, Tanja N.; Nystrom, Elizabeth A.; Milly, Paul C.D.

    2016-01-01

    The Delaware River Basin (DRB) encompasses approximately 0.4 % of the area of the United States (U.S.), but supplies water to 5 % of the population. We studied three forested tributaries to quantify the potential climate-driven change in hydrologic budget for two 25-year time periods centered on 2030 and 2060, focusing on sensitivity to the method of estimating potential evapotranspiration (PET) change. Hydrology was simulated using the Water Availability Tool for Environmental Resources (Williamson et al. 2015). Climate-change scenarios for four Coupled Model Intercomparison Project Phase 5 (CMIP5) global climate models (GCMs) and two Representative Concentration Pathways (RCPs) were used to derive monthly change factors for temperature (T), precipitation (PPT), and PET according to the energy-based method of Priestley and Taylor (1972). Hydrologic simulations indicate a general increase in annual (especially winter) streamflow (Q) as early as 2030 across the DRB, with a larger increase by 2060. This increase in Q is the result of (1) higher winter PPT, which outweighs an annual actual evapotranspiration (AET) increase and (2) (for winter) a major shift away from storage of PPT as snow pack. However, when PET change is evaluated instead using the simpler T-based method of Hamon (1963), the increases in Q are small or even negative. In fact, the change of Q depends as much on PET method as on time period or RCP. This large sensitivity and associated uncertainty underscore the importance of exercising caution in the selection of a PET method for use in climate-change analyses.

  3. Characterization of Large-Area SiPM Array for PET Applications

    NASA Astrophysics Data System (ADS)

    Du, Junwei; Yang, Yongfeng; Bai, Xiaowei; Judenhofer, Martin S.; Berg, Eric; Di, Kun; Buckley, Steve; Jackson, Carl; Cherry, Simon R.

    2016-02-01

    The performance of an 8 ×8 array of 6.0 ×6.0 mm2 (active area) SiPMs was evaluated for PET applications using crystal arrays with different pitch sizes (3.4, 1.5, 1.35, and 1.2 mm) and custom designed five-channel front-end readout electronics (four channels for position information and one channel for timing information). The total area of this SiPM array is 57.4 ×57.4 mm2, and the pitch size is 7.2 mm. It was fabricated using enhanced blue sensitivity SiPMs (MicroFB-60035-SMT) with peak spectral sensitivity at 420 nm. The performance of the SiPM array was characterized by measuring flood histogram decoding quality, energy resolution, timing resolution and saturation at several bias voltages (from 25.0 to 30.0 V in 0.5 V intervals) and two different temperatures ( 5° C and 20°C). Results show that the best flood histogram was obtained at a bias voltage of 28.0 V and 5°C and an array of polished LSO crystals with a pitch as small as 1.2 mm can be resolved. No saturation was observed up to a bias voltage of 29.5 V during the experiments, due to adequate light sharing between SiPMs. Energy resolution and timing resolution at 5°C ranged from 12.7 ±0.8% to 14.6 ±1.4% and 1.58 ±0.13 ns to 2.50 ±0.44 ns, for crystal array pitch sizes of 3.4 and 1.2 mm, respectively. Superior flood histogram quality, energy resolution and timing resolution were obtained with larger crystal array pitch sizes and at lower temperature. Based on our findings, we conclude that this large-area SiPM array can serve as a suitable photodetector for high-resolution small-animal PET or dedicated human brain PET scanners.

  4. Al18F-Labeling Of Heat-Sensitive Biomolecules for Positron Emission Tomography Imaging

    PubMed Central

    Cleeren, Frederik; Lecina, Joan; Ahamed, Muneer; Raes, Geert; Devoogdt, Nick; Caveliers, Vicky; McQuade, Paul; Rubins, Daniel J; Li, Wenping; Verbruggen, Alfons; Xavier, Catarina; Bormans, Guy

    2017-01-01

    Positron emission tomography (PET) using radiolabeled biomolecules is a translational molecular imaging technology that is increasingly used in support of drug development. Current methods for radiolabeling biomolecules with fluorine-18 are laborious and require multistep procedures with moderate labeling yields. The Al18F-labeling strategy involves chelation in aqueous medium of aluminum mono[18F]fluoride ({Al18F}2+) by a suitable chelator conjugated to a biomolecule. However, the need for elevated temperatures (100-120 °C) required for the chelation reaction limits its widespread use. Therefore, we designed a new restrained complexing agent (RESCA) for application of the AlF strategy at room temperature. Methods. The new chelator RESCA was conjugated to three relevant biologicals and the constructs were labeled with {Al18F}2+ to evaluate the generic applicability of the one-step Al18F-RESCA-method. Results. We successfully labeled human serum albumin with excellent radiochemical yields in less than 30 minutes and confirmed in vivo stability of the Al18F-labeled protein in rats. In addition, we efficiently labeled nanobodies targeting the Kupffer cell marker CRIg, and performed µPET studies in healthy and CRIg deficient mice to demonstrate that the proposed radiolabeling method does not affect the functional integrity of the protein. Finally, an affibody targeting HER2 (PEP04314) was labeled site-specifically, and the distribution profile of (±)-[18F]AlF(RESCA)-PEP04314 in a rhesus monkey was compared with that of [18F]AlF(NOTA)-PEP04314 using whole-body PET/CT. Conclusion. This generic radiolabeling method has the potential to be a kit-based fluorine-18 labeling strategy, and could have a large impact on PET radiochemical space, potentially enabling the development of many new fluorine-18 labeled protein-based radiotracers. PMID:28824726

  5. Synthesis and radiolabeling of chelator-RNA aptamer bioconjugates with copper-64 for targeted molecular imaging

    PubMed Central

    Rockey, William M.; Huang, Ling; Kloepping, Kyle C.; Baumhover, Nicholas J.; Giangrande, Paloma H.; Schultz, Michael K.

    2014-01-01

    Ribonucleic acid (RNA) aptamers with high affinity and specificity for cancer-specific cell-surface antigens are promising reagents for targeted molecular imaging of cancer using positron emission tomography (PET). For this application, aptamers must be conjugated to chelators capable of coordinating PET-radionuclides (e.g. copper-64, 64Cu) to enable radiolabeling for in vivo imaging of tumors. This study investigates the choice of chelator and radiolabeling parameters such as pH and temperature for the development of 64Cu-labeled RNA-based targeted agents for PET imaging. The characterization and optimization of labeling conditions are described for four chelator-aptamer complexes. Three commercially available bifunctional macrocyclic chelators (1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid mono N-hydroxysuccinimide [DOTA-NHS]; S-2-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid [p-SCN-Bn-NOTA]; and p-SCN-Bn-3,6,9,15-tetraazabicyclo [9.3.1]pentadeca-1(15),11,13-triene-3,6,9-triacetic acid [p-SCN-Bn-PCTA]), as well as the polyamino-macrocyclic diAmSar (3,6,10,13,16,19-hexaazabicyclo[6.6.6] icosane-1,8-diamine) were conjugated to A10–3.2, a RNA aptamer which has been shown to bind specifically to a prostate cancer-specific cell-surface antigen (PSMA). Although a commercial bifunctional version of diAmSar was not available, RNA conjugation with this chelator was achieved in a two-step reaction by the addition of a disuccinimidyl suberate linker. Radiolabeling parameters (e.g. pH, temperature, and time) for each chelator-RNA conjugate were assessed in order to optimize specific activity and RNA stability. Furthermore, the radiolabeled chelator-coupled RNA aptamers were evaluated for binding specificity to their target antigen. In summary, key parameters were established for optimal radiolabeling of RNA aptamers for eventual PET imaging with 64Cu. PMID:21658962

  6. Recovering the triple coincidence of non-pure positron emitters in preclinical PET

    NASA Astrophysics Data System (ADS)

    Lin, Hsin-Hon; Chuang, Keh-Shih; Chen, Szu-Yu; Jan, Meei-Ling

    2016-03-01

    Non-pure positron emitters, with their long half-lives, allow for the tracing of slow biochemical processes which cannot be adequately examined by the commonly used short-lived positron emitters. Most of these isotopes emit high-energy cascade gamma rays in addition to positron decay that can be detected and create a triple coincidence with annihilation photons. Triple coincidence is discarded in most scanners, however, the majority of the triple coincidence contains true photon pairs that can be recovered. In this study, we propose a strategy for recovering triple coincidence events to raise the sensitivity of PET imaging for non-pure positron emitters. To identify the true line of response (LOR) from a triple coincidence, a framework utilizing geometrical, energy and temporal information is proposed. The geometrical criterion is based on the assumption that the LOR with the largest radial offset among the three sub pairs of triple coincidences is least likely to be a true LOR. Then, a confidence time window is used to test the valid LOR among those within triple coincidence. Finally, a likelihood ratio discriminant rule based on the energy probability density distribution of cascade and annihilation gammas is established to identify the true LOR. An Inveon preclinical PET scanner was modeled with GATE (GEANT4 application for tomographic emission) Monte Carlo software. We evaluated the performance of the proposed method in terms of identification fraction, noise equivalent count rates (NECR), and image quality on various phantoms. With the inclusion of triple coincidence events using the proposed method, the NECR was found to increase from 11% to 26% and 19% to 29% for I-124 and Br-76, respectively, when 7.4-185 MBq of activity was used. Compared to the reconstructed images using double coincidence, this technique increased the SNR by 5.1-7.3% for I-124 and 9.3-10.3% for Br-76 within the activity range of 9.25-74 MBq, without compromising the spatial resolution or contrast. We conclude that the proposed method can improve the counting statistics of PET imaging for non-pure positron emitters and is ready to be implemented on current PET systems. Parts of this work were presented at the 2012 Annual Congress of the European Association of Nuclear Medicine.

  7. The effects of segmentation algorithms on the measurement of 18F-FDG PET texture parameters in non-small cell lung cancer.

    PubMed

    Bashir, Usman; Azad, Gurdip; Siddique, Muhammad Musib; Dhillon, Saana; Patel, Nikheel; Bassett, Paul; Landau, David; Goh, Vicky; Cook, Gary

    2017-12-01

    Measures of tumour heterogeneity derived from 18-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) scans are increasingly reported as potential biomarkers of non-small cell lung cancer (NSCLC) for classification and prognostication. Several segmentation algorithms have been used to delineate tumours, but their effects on the reproducibility and predictive and prognostic capability of derived parameters have not been evaluated. The purpose of our study was to retrospectively compare various segmentation algorithms in terms of inter-observer reproducibility and prognostic capability of texture parameters derived from non-small cell lung cancer (NSCLC) 18 F-FDG PET/CT images. Fifty three NSCLC patients (mean age 65.8 years; 31 males) underwent pre-chemoradiotherapy 18 F-FDG PET/CT scans. Three readers segmented tumours using freehand (FH), 40% of maximum intensity threshold (40P), and fuzzy locally adaptive Bayesian (FLAB) algorithms. Intraclass correlation coefficient (ICC) was used to measure the inter-observer variability of the texture features derived by the three segmentation algorithms. Univariate cox regression was used on 12 commonly reported texture features to predict overall survival (OS) for each segmentation algorithm. Model quality was compared across segmentation algorithms using Akaike information criterion (AIC). 40P was the most reproducible algorithm (median ICC 0.9; interquartile range [IQR] 0.85-0.92) compared with FLAB (median ICC 0.83; IQR 0.77-0.86) and FH (median ICC 0.77; IQR 0.7-0.85). On univariate cox regression analysis, 40P found 2 out of 12 variables, i.e. first-order entropy and grey-level co-occurence matrix (GLCM) entropy, to be significantly associated with OS; FH and FLAB found 1, i.e., first-order entropy. For each tested variable, survival models for all three segmentation algorithms were of similar quality, exhibiting comparable AIC values with overlapping 95% CIs. Compared with both FLAB and FH, segmentation with 40P yields superior inter-observer reproducibility of texture features. Survival models generated by all three segmentation algorithms are of at least equivalent utility. Our findings suggest that a segmentation algorithm using a 40% of maximum threshold is acceptable for texture analysis of 18 F-FDG PET in NSCLC.

  8. 44Sc-DOTA-BN[2-14]NH2 in comparison to 68Ga-DOTA-BN[2-14]NH2 in pre-clinical investigation. Is 44Sc a potential radionuclide for PET?

    PubMed

    Koumarianou, E; Loktionova, N S; Fellner, M; Roesch, F; Thews, O; Pawlak, D; Archimandritis, S C; Mikolajczak, R

    2012-12-01

    In the present study we demonstrate the in vitro and in vivo comparison of the (44)Sc and (68)Ga labeled DOTA-BN[2-14]NH(2). (44)Sc is a positron emitter with a half life of 3.92 h. Hence it could be used for PET imaging with ligands requiring longer observation time than in the case of (68)Ga. The binding affinity of (nat)Sc-DOTA-BN[2-14]NH(2) and (nat)Ga-DOTA-BN[2-14]NH(2) to GRP receptors was studied in competition to [(125)I-Tyr(4)]-Bombesin in the human prostate cancer cell line PC-3. A preliminary biodistribution in normal rats was performed, while first microPET images were assessed in male Copenhagen rats bearing the androgen-independent Dunning R-3327-AT-1 prostate cancer tumor. The affinity to GRP receptors in the PC-3 cell line was higher for (nat)Ga-DOTA-BN[2-14]NH(2) (IC(50)(nM)=0.85 ± 0.06) than that of (nat)Sc-DOTA-BN[2-14]NH(2) (IC(50) (nM)=6.49 ± 0.13). The internalization rate of (68)Ga labeled DOTA-BN[2-14]NH(2) was slower than that of (44)Sc, but their final internalization percents were comparable. (68)Ga-DOTA-BN[2-14]NH(2) was externalized faster than (44)Sc-DOTA-BN[2-14]NH(2). The biodistribution of (44)Sc-DOTA-BN[2-14]NH(2) and (68)Ga-DOTA-BN[2-14]NH(2) in normal rats revealed a higher uptake in target organs and tissues of the first one while both excreted mainly through urinary tract. In microPET images both tracers were accumulated in the tumor with similar uptake patterns. Despite the differences in the receptor affinity both the (68)Ga- and the (44)Sc-labeled DOTA-BN[2-14]NH(2) tracers showed comparable distribution and similar time constants of uptake and elimination. Moreover no differences in tumor accumulation (neither in the overall uptake nor in the dynamics) were observed from the microPet imaging. From that perspective the use of either (44)Sc or (68)Ga for detecting tumors with GRP receptors is equivalent. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Performance Evaluation of a New Dedicated Breast PET Scanner Using NEMA NU4-2008 Standards.

    PubMed

    Miyake, Kanae K; Matsumoto, Keiichi; Inoue, Mika; Nakamoto, Yuji; Kanao, Shotaro; Oishi, Tae; Kawase, Shigeto; Kitamura, Keishi; Yamakawa, Yoshiyuki; Akazawa, Ayako; Kobayashi, Tetsuya; Ohi, Junichi; Togashi, Kaori

    2014-07-01

    The aim of this work was to evaluate the performance characteristics of a newly developed dedicated breast PET scanner, according to National Electrical Manufacturers Association (NEMA) NU 4-2008 standards. The dedicated breast PET scanner consists of 4 layers of a 32 × 32 lutetium oxyorthosilicate-based crystal array, a light guide, and a 64-channel position-sensitive photomultiplier tube. The size of a crystal element is 1.44 × 1.44 × 4.5 mm. The detector ring has a large solid angle with a 185-mm aperture and an axial coverage of 155.5 mm. The energy windows at depth of interaction for the first and second layers are 400-800 keV, and those at the third and fourth layers are 100-800 keV. A fixed timing window of 4.5 ns was used for all acquisitions. Spatial resolution, sensitivity, counting rate capabilities, and image quality were evaluated in accordance with NEMA NU 4-2008 standards. Human imaging was performed in addition to the evaluation. Radial, tangential, and axial spatial resolution measured as minimal full width at half maximum approached 1.6, 1.7, and 2.0 mm, respectively, for filtered backprojection reconstruction and 0.8, 0.8, and 0.8 mm, respectively, for dynamic row-action maximum-likelihood algorithm reconstruction. The peak absolute sensitivity of the system was 11.2%. Scatter fraction at the same acquisition settings was 30.1% for the rat-sized phantom. Peak noise-equivalent counting rate and peak true rate for the ratlike phantom was 374 kcps at 25 MBq and 603 kcps at 31 MBq, respectively. In the image-quality phantom study, recovery coefficients and uniformity were 0.04-0.82 and 1.9%, respectively, for standard reconstruction mode and 0.09-0.97 and 4.5%, respectively, for enhanced-resolution mode. Human imaging provided high-contrast images with restricted background noise for standard reconstruction mode and high-resolution images for enhanced-resolution mode. The dedicated breast PET scanner has excellent spatial resolution and high sensitivity. The performance of the dedicated breast PET scanner is considered to be reasonable enough to support its use in breast cancer imaging. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  10. GATE Monte Carlo simulation of GE Discovery 600 and a uniformity phantom

    NASA Astrophysics Data System (ADS)

    Sheen, Heesoon; Im, Ki Chun; Choi, Yong; Shin, Hanback; Han, Youngyih; Chung, Kwangzoo; Cho, Junsang; Ahn, Sang Hee

    2014-12-01

    GATE (Geant4 Application Tomography Emission) Monte Carlo simulations have been successful in the application of emission tomography for precise modeling of various physical processes. Most previous studies on Monte Carlo simulations have only involved performance assessments using virtual phantoms. Although that allows the performance of simulated positron emission tomography (PET) to be evaluated, it does not reflect the reality of practical conditions. This restriction causes substantial drawbacks in GATE simulations of real situations. To overcome the described limitation and to provide a method to enable simulation research relevant to clinically important issues, we conducted a GATE simulation using real data from a scanner rather than a virtual phantom and evaluated the scanner is performance. For that purpose, the system and the geometry of a commercial GE PET/ CT (computed tomography) scanner, BGO-based Discovery 600 (D600), was developed for the first time. The performance of the modeled PET system was evaluated by using the National Electrical Manufacturers Association NEMA NU 2-2007 protocols and results were compared with those of the reference data. The sensitivity, scatter fraction, noise-equivalent count rate (NECR), and resolution were estimated by using the protocol of the NEMA NU2-2007. Sensitivities were 9.01 cps/kBq at 0 cm and 9.43 cps/kBq at 10 cm. Scatter fractions were 39.5%. The NECR peak was 89.7 kcps @ 14.7 kBq/cc. Resolutions were 4.8 mm in the transaxial plane and 5.9 mm in the axial plane at 1 cm, and 6.2 mm in the transaxial plane and 6.4 mm in the axial plane at 10 cm. The resolutions exceeded the limited value provided by the manufacturer. The uniformity phantom was simulated using the CT and the PET data. The output data in a ROOT format were converted and then reconstructed by using the C program and STIR (Software for Tomographic Image Reconstruction). The reconstructed images of the simulated uniformity phantom data had comparable quality even though improvement in the quality is still required. In conclusion, we have demonstrated a successful simulation of a PET system by using scanned data. In future studies, the parameters that alter the imaging conditions, such as patient movement and physiological change, need to be studied.

  11. Ignition of lean fuel-air mixtures in a premixing-prevaporizing duct at temperatures up to 1000 K

    NASA Technical Reports Server (NTRS)

    Tacina, R. R.

    1980-01-01

    Conditions were determined in a premixing prevaporizing fuel preparation duct at which ignition occurred. An air blast type fuel injector with nineteen fuel injection points was used to provide a uniform spatial fuel air mixture. The range of inlet conditions where ignition occurred were: inlet air temperatures of 600 to 1000 K air pressures of 180 to 660 kPa, equivalence ratios (fuel air ratio divided by stoichiometric fuel air ratio) from 0.12 to 1.05, and velocities from 3.5 to 30 m/s. The duct was insulated and the diameter was 12 cm. Mixing lengths were varied from 16.5 to 47.6 and residence times ranged from 4.6 to 107 ms. The fuel was no. 2 diesel. Results show a strong effect of equivalence ratio, pressure and temperature on the conditions where ignition occurred. The data did not fit the most commonly used model of auto-ignition. A correlation of the conditions where ignition would occur which apply to this test apparatus over the conditions tested is (p/V) phi to the 1.3 power = 0.62 e to the 2804/T power where p is the pressure in kPa, V is the velocity in m/e, phi is the equivalence ratio, and T is the temperature in K. The data scatter was considerable, varying by a maximum value of 5 at a given temperature and equivalence ratio. There was wide spread in the autoignition data contained in the references.

  12. Thermal comfort in an east-west oriented street canyon in Freiburg (Germany) under hot summer conditions

    NASA Astrophysics Data System (ADS)

    Ali-Toudert, F.; Mayer, H.

    2007-01-01

    Field-measurements were conducted in an urban street canyon with an east-west orientation, and a height-to-width ratio H/W = 1 during cloudless summer weather in 2003 in Freiburg, Germany. This experimental work adds to the knowledge available on the microclimate of an urban canyon and its impact on human comfort. Air temperature T a , air humidity VP, wind speed v and direction dd were measured continuously. All short-wave and long-wave radiation fluxes from the 3D surroundings were also measured. The degree of comfort was defined in terms of physiologically equivalent temperature (PET). Furthermore, the data gathered within the canyon were compared to data collected by a permanent urban climate station with the aim of furthering the understanding of microclimatic changes due to street geometry. Changes in the meteorological variables T a , v and dd in the canyon in comparison to an unobstructed roof level location were found to be in good agreement with previous studies, i.e., a small increase of T a in the canyon adjacent to irradiated surfaces, and a good correlation of v and dd between canyon and roof levels. The daily dynamics of canyon facet irradiances and their impacts on the heat gained by a pedestrian were strongly dependent on street geometry and orientation. Thermal stress was mostly attributable to solar exposure. Under cloudless summer weather, a standing body was found to absorb, on average, 74% of heat in the form of long-wave irradiance and 26% as short-wave irradiance. Shading the pedestrian as well as the surrounding surfaces is, hence, the first strategy in mitigating heat stress in summer under hot conditions.

  13. Bistability in dual-frequency nematic liquid crystals

    NASA Astrophysics Data System (ADS)

    Palto, S. P.; Barnik, M. I.

    2007-03-01

    Different modes of bistable switching in liquid crystals with frequency inversion of the dielectric anisotropy sign are discussed. The study is performed by numerical simulation and experimentally. It is shown that dual frequency driving can be effectively used to control switching between topologically equivalent and non-equivalent director field distributions. The experimental results on temperature performance of the dual-frequency switching and possible driving methods for energy consumption and expanding the temperature range are presented.

  14. Trends in atmospheric evaporative demand in Great Britain using high-resolution meteorological data

    NASA Astrophysics Data System (ADS)

    Robinson, Emma L.; Blyth, Eleanor M.; Clark, Douglas B.; Finch, Jon; Rudd, Alison C.

    2017-02-01

    Observations of climate are often available on very different spatial scales from observations of the natural environments and resources that are affected by climate change. In order to help bridge the gap between these scales using modelling, a new dataset of daily meteorological variables was created at 1 km resolution over Great Britain for the years 1961-2012, by interpolating coarser resolution climate data and including the effects of local topography. These variables were used to calculate atmospheric evaporative demand (AED) at the same spatial and temporal resolution. Two functions that represent AED were chosen: one is a standard form of potential evapotranspiration (PET) and the other is a derived PET measure used by hydrologists that includes the effect of water intercepted by the canopy (PETI). Temporal trends in these functions were calculated, with PET found to be increasing in all regions, and at an overall rate of 0.021 ± 0.021 mm day-1 decade-1 in Great Britain. PETI was found to be increasing at a rate of 0.019 ± 0.020 mm day-1 decade-1 in Great Britain, but this was not statistically significant. However, there was a trend in PETI in England of 0.023 ± 0.023 mm day-1 decade-1. The trends were found to vary by season, with spring PET increasing by 0.043 ± 0.019 mm day-1 decade-1 (0.038 ± 0.018 mm day-1 decade-1 when the interception correction is included) in Great Britain, while there is no statistically significant trend in other seasons. The trends were attributed analytically to trends in the climate variables; the overall positive trend was predominantly driven by rising air temperature, although rising specific humidity had a negative effect on the trend. Recasting the analysis in terms of relative humidity revealed that the overall effect is that falling relative humidity causes the PET to rise. Increasing downward short- and longwave radiation made an overall positive contribution to the PET trend, while decreasing wind speed made a negative contribution to the trend in PET. The trend in spring PET was particularly strong due to a strong decrease in relative humidity and increase in downward shortwave radiation in the spring.

  15. Characterization of zero-bias microwave diode power detectors at cryogenic temperature.

    PubMed

    Giordano, Vincent; Fluhr, Christophe; Dubois, Benoît; Rubiola, Enrico

    2016-08-01

    We present the characterization of commercial tunnel diode low-level microwave power detectors at room and cryogenic temperatures. The sensitivity as well as the output voltage noise of the tunnel diodes is measured as functions of the applied microwave power. We highlight strong variations of the diode characteristics when the applied microwave power is higher than a few microwatts. For a diode operating at 4 K, the differential gain increases from 1000 V/W to about 4500 V/W when the power passes from -30 dBm to -20 dBm. The diode white noise floor is equivalent to a Noise Equivalent Power of 0.8 pW/Hz and 8 pW/Hz at 4 K and 300 K, respectively. Its flicker noise is equivalent to a relative amplitude noise power spectral density Sα(1 Hz) = - 120 dB/Hz at 4 K. Flicker noise is 10 dB higher at room temperature.

  16. Climate specific thermomechanical fatigue of flat plate photovoltaic module solder joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosco, Nick; Silverman, Timothy J.; Kurtz, Sarah

    FEM simulations of PbSn solder fatigue damage are used to evaluate seven cities that represent a variety of climatic zones. It is shown that the rate of solder fatigue damage is not ranked with the cities' climate designations. For an accurate ranking, the mean maximum daily temperature, daily temperature change and a characteristic of clouding events are all required. A physics-based empirical equation is presented that accurately calculates solder fatigue damage according to these three factors. An FEM comparison of solder damage accumulated through service and thermal cycling demonstrates the number of cycles required for an equivalent exposure. For anmore » equivalent 25-year exposure, the number of thermal cycles (-40 degrees C to 85 degrees C) required ranged from roughly 100 to 630 for the cities examined. It is demonstrated that increasing the maximum cycle temperature may significantly reduce the number of thermal cycles required for an equivalent exposure.« less

  17. PSA-stratified detection rates for [68Ga]THP-PSMA, a novel probe for rapid kit-based 68Ga-labeling and PET imaging, in patients with biochemical recurrence after primary therapy for prostate cancer.

    PubMed

    Derlin, Thorsten; Schmuck, Sebastian; Juhl, Cathleen; Zörgiebel, Johanna; Schneefeld, Sophie M; Walte, Almut C A; Hueper, Katja; von Klot, Christoph A; Henkenberens, Christoph; Christiansen, Hans; Thackeray, James T; Ross, Tobias L; Bengel, Frank M

    2018-06-01

    [ 68 Ga]Tris(hydroxypyridinone)(THP)-PSMA is a novel radiopharmaceutical for one-step kit-based radiolabelling, based on direct chelation of 68 Ga 3+ at low concentration, room temperature and over a wide pH range, using direct elution from a 68 Ge/ 68 Ga-generator. We evaluated the clinical detection rates of [ 68 Ga]THP-PSMA PET/CT in patients with biochemically recurrent prostate cancer after prostatectomy. Consecutive patients (n=99) referred for evaluation of biochemical relapse of prostate cancer by [ 68 Ga]THP-PSMA PET/CT were analyzed retrospectively. Patients underwent a standard whole-body PET/CT (1 h p.i.), followed by delayed (3 h p.i.) imaging of the abdomen. PSA-stratified cohorts of positive PET/CT results, standardized uptake values (SUVs) and target-to-background ratios (TBRs) were analyzed, and compared between standard and delayed imaging. At least one lesion suggestive of recurrent or metastatic prostate cancer was identified on PET images in 52 patients (52.5%). Detection rates of [ 68 Ga]THP-PSMA PET/CT increased with increasing PSA level: 94.1% for a PSA value of ≥10 ng/mL, 77.3% for a PSA value of 2 to <10 ng/mL, 54.5% for a PSA value of 1 to <2 ng/mL, 14.3% for a PSA value of 0.5 to <1 ng/mL, 20.0% for a PSA value of >0.2 to <0.5, and 22.2% for a PSA value of 0.01 to 0.2 ng/mL. [ 68 Ga]THP-PSMA uptake (SUVs) in metastases decreased over time, whereas TBRs improved. Delayed imaging at 3 h p.i. exclusively identified pathologic findings in 2% of [ 68 Ga]THP-PSMA PET/CT scans. Detection rate was higher in patients with a Gleason score ≥8 (P=0.02) and in patients receiving androgen deprivation therapy (P=0.003). In this study, [ 68 Ga]THP-PSMA PET/CT showed suitable detection rates in patients with biochemical recurrence of prostate cancer and PSA levels ≥ 2 ng /mL. Detections rates were lower than in previous studies evaluating other PSMA ligands, though prospective direct radiotracer comparison studies are mandatory particularly in patients with low PSA levels to evaluate the relative performance of different PSMA ligands.

  18. Evaluation of a novel GRPR antagonist for prostate cancer PET imaging: [64Cu]-DOTHA2-PEG-RM26.

    PubMed

    Mansour, Nematallah; Paquette, Michel; Ait-Mohand, Samia; Dumulon-Perreault, Véronique; Guérin, Brigitte

    2018-01-01

    Gastrin releasing peptide receptors (GRPRs) are significantly over-expressed on a large proportion of prostate cancers making them prime candidates for receptor-mediated nuclear imaging by PET. Recently, we synthesized a novel bifunctional chelator (BFC) bearing hydroxamic acid arms (DOTHA 2 ). Here we investigated the potential of a novel DOTHA 2 -conjugated, 64 Cu-radiolabeled GRPR peptide antagonist, [D-Phe 6 -Sta 13 -Leu 14 -NH 2 ]bombesin(6-14) (DOTHA 2 -PEG-RM26) to visualize prostate tumors by PET imaging. DOTHA 2 -PEG-RM26 was conveniently and efficiently assembled on solid support. The compound was radiolabeled with 64 Cu and its affinity, stability, cellular uptake on PC3 prostate cancer cells were evaluated. The in vitro and in vivo behavior of [ 64 Cu]DOTHA 2 -PEG-RM26 was examined by PET imaging using human PC3 prostate cancer xenografts and its behavior was compared to that of the analogous [ 64 Cu]NOTA-PEG-RM26. The inhibition constant of nat Cu-DOTHA 2 -PEG-RM26 was in the low nanomolar range (0.68±0.19 nM). The [ 64 Cu]DOTHA 2 -PEG-RM26 conjugate was prepared with a labeling yield >95% and molar activity of 56±3 GBq/μmol after a 5-min room temperature labeling. [ 64 Cu]-DOTHA 2 -PEG-RM26 demonstrated rapid blood and renal clearance as well as a high tumor uptake. Small animal PET images confirmed high and specific uptake in PC3 tumor. Both [ 64 Cu]-DOTHA 2 -PEG-RM26 and [ 64 Cu]-NOTA-PEG-RM26 displayed similar tumor and normal tissue uptakes at early time point post injection. [ 64 Cu]-DOTHA 2 -PEG-RM26 allows visualization of prostate tumors by PET imaging. DOTHA 2 enables fast 64 Cu chelation under mild condition, and as such could be used advantageously for the development of other 64 Cu-labeled peptide-derived PET tracers. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Equivalent damage: A critical assessment

    NASA Technical Reports Server (NTRS)

    Laflen, J. R.; Cook, T. S.

    1982-01-01

    Concepts in equivalent damage were evaluated to determine their applicability to the life prediction of hot path components of aircraft gas turbine engines. Equivalent damage was defined as being those effects which influence the crack initiation life-time beyond the damage that is measured in uniaxial, fully-reversed sinusoidal and isothermal experiments at low homologous temperatures. Three areas of equivalent damage were examined: mean stress, cumulative damage, and multiaxiality. For each area, a literature survey was conducted to aid in selecting the most appropriate theories. Where possible, data correlations were also used in the evaluation process. A set of criteria was developed for ranking the theories in each equivalent damage regime. These criteria considered aspects of engine utilization as well as the theoretical basis and correlative ability of each theory. In addition, consideration was given to the complex nature of the loading cycle at fatigue critical locations of hot path components; this loading includes non-proportional multiaxial stressing, combined temperature and strain fluctuations, and general creep-fatigue interactions. Through applications of selected equivalent damage theories to some suitable data sets it was found that there is insufficient data to allow specific recommendations of preferred theories for general applications. A series of experiments and areas of further investigations were identified.

  20. Air quality perception of pedestrians in an urban outdoor Mediterranean environment: A field survey approach.

    PubMed

    Pantavou, Katerina; Lykoudis, Spyridon; Psiloglou, Basil

    2017-01-01

    Perception plays a significant role on people's response to preventive measures. In the view of public awareness, the aim of this study was to explore factors that affect air quality perception and to reveal its potential patterns. Air quality perception of individuals, in terms of dust and overall air quality, was examined in relation to air pollutants concentrations, meteorological variables, personal characteristics as well as their thermal sensation and health condition. The data used were obtained from environmental measurements, in situ and from stations, and questionnaire surveys conducted in an outdoor urban Mediterranean area, Athens, Greece. The participants were asked to report their air quality perception and thermal sensation based on predefined scales. A thermal index, Physiological Equivalent Temperature (PET), was estimated to obtain an objective measure of thermal sensation. Particulate matter (PM 10 ) and nitrogen oxide (NO) were associated with dust perception. Nitrogen oxides (NO x ) and carbon monoxide (CO) were associated to air quality perception. Age, area of residence, health symptoms and thermal sensation also affected the perception of air quality. Dusty or poor air quality conditions were more likely to be reported when pollutants' concentrations were increased. Younger people, participants residing in the city center, experiencing health symptoms or warm thermal sensation showed a trend towards reporting more unfavorable air quality conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

Top