Poulsen, Torben; Oakley, Sebastian
2009-05-01
Hearing threshold sound pressure levels were measured for the Sennheiser HDA 280 audiometric earphone. Hearing thresholds were measured for 25 normal-hearing test subjects at the 11 audiometric test frequencies from 125 Hz to 8000 Hz. Sennheiser HDA 280 is a supra-aural earphone that may be seen as a substitute for the classical Telephonics TDH 39. The results are given as the equivalent threshold sound pressure level (ETSPL) measured in an acoustic coupler specified in IEC 60318-3. The results are in good agreement with an independent investigation from PTB, Braunschweig, Germany. From acoustic laboratory measurements ETSPL values are calculated for the ear simulator specified in IEC 60318-1. Fitting of earphone and coupler is discussed. The data may be used for a future update of the RETSPL standard for supra-aural audiometric earphones, ISO 389-1.
Going wireless and booth-less for hearing testing in industry.
Meinke, Deanna K; Norris, Jesse A; Flynn, Brendan P; Clavier, Odile H
2017-01-01
To assess the test-retest variability of hearing thresholds obtained with an innovative, mobile wireless automated hearing-test system (WAHTS) with enhanced sound attenuation to test industrial workers at a worksite as compared to standardised automated hearing thresholds obtained in a mobile trailer sound booth. A within-subject repeated-measures design was used to compare air-conducted threshold tests (500-8000 Hz) measured with the WAHTS in six workplace locations, and a third test using computer-controlled audiometry obtained in a mobile trailer sound booth. Ambient noise levels were measured in all test environments. Twenty workers served as listeners and 20 workers served as operators. On average, the WAHTS resulted in equivalent thresholds as the mobile trailer audiometry at 1000, 2000, 3000 and 8000 Hz and thresholds were within ±5 dB at 500, 4000 and 6000 Hz. Comparable performance may be obtained with the WAHTS in occupational audiometry and valid thresholds may be obtained in diverse test locations without the use of sound-attenuating enclosures.
Popov, Vladimir V; Supin, Alexander Ya; Rozhnov, Viatcheslav V; Nechaev, Dmitry I; Sysueva, Evgenia V
2014-05-15
The influence of fatiguing sound level and duration on post-exposure temporary threshold shift (TTS) was investigated in two beluga whales (Delphinapterus leucas). The fatiguing sound was half-octave noise with a center frequency of 22.5 kHz. TTS was measured at a test frequency of 32 kHz. Thresholds were measured by recording rhythmic evoked potentials (the envelope following response) to a test series of short (eight cycles) tone pips with a pip rate of 1000 s(-1). TTS increased approximately proportionally to the dB measure of both sound pressure (sound pressure level, SPL) and duration of the fatiguing noise, as a product of these two variables. In particular, when the noise parameters varied in a manner that maintained the product of squared sound pressure and time (sound exposure level, SEL, which is equivalent to the overall noise energy) at a constant level, TTS was not constant. Keeping SEL constant, the highest TTS appeared at an intermediate ratio of SPL to sound duration and decreased at both higher and lower ratios. Multiplication (SPL multiplied by log duration) better described the experimental data than an equal-energy (equal SEL) model. The use of SEL as a sole universal metric may result in an implausible assessment of the impact of a fatiguing sound on hearing thresholds in odontocetes, including under-evaluation of potential risks. © 2014. Published by The Company of Biologists Ltd.
Field hearing measurements of the Atlantic sharpnose shark Rhizoprionodon terraenovae.
Casper, B M; Mann, D A
2009-12-01
Field measurements of hearing thresholds were obtained from the Atlantic sharpnose shark Rhizoprionodon terraenovae using the auditory evoked potential method (AEP). The fish had most sensitive hearing at 20 Hz, the lowest frequency tested, with decreasing sensitivity at higher frequencies. Hearing thresholds were lower than AEP thresholds previously measured for the nurse shark Ginglymostoma cirratum and yellow stingray Urobatis jamaicensis at frequencies <200 Hz, and similar at 200 Hz and above. Rhizoprionodon terraenovae represents the closest comparison in terms of pelagic lifestyle to the sharks which have been observed in acoustic field attraction experiments. The sound pressure levels that would be equivalent to the particle acceleration thresholds of R. terraenovae were much higher than the sound levels which attracted closely related sharks suggesting a discrepancy between the hearing threshold experiments and the field attraction experiments.
NASA Astrophysics Data System (ADS)
Hiramatsu, K.; Matsui, T.; Ito, A.; Miyakita, T.; Osada, Y.; Yamamoto, T.
2004-10-01
Aircraft noise measurements were recorded at the residential areas in the vicinity of Kadena Air Base, Okinawa in 1968 and 1972 at the time of the Vietnam war. The estimated equivalent continuous A-weighted sound pressure level LAeq for 24 h was 85 dB.The time history of sound level during 24 h was estimated from the measurement conducted in 1968, and the sound level was converted into the spectrum level at the centre frequency of the critical band of temporary threshold shift (TTS) using the results of spectrum analysis of aircraft noise operated at the airfield. With the information of spectrum level and its time history, TTS was calculated as a function of time and level change. The permanent threshold shift was also calculated by means of Robinson's method and ISO's method. The results indicate the noise exposure around Kadena Air Base was hazardous to hearing and is likely to have caused hearing loss to people living in its vicinity.
Investigations of ionospheric sporadic Es layer using oblique sounding method
NASA Astrophysics Data System (ADS)
Minullin, R.
The characteristics of Es layer have been studied using oblique sounding at 28 radiolines at the frequencies of 34 -- 73 MHz at the transmission paths 400 -- 1600 km long during 30 years. Reflections from Es layer with a few hours duration were observed. The amplitude of the reflected signal reached 1000 μ V with the registration threshold 0,1 μ V. The borderlines between reflected and scattered signals were observed as sharp curves in 60 -- 100 s range on the distributions of duration of reflected signals for decameter waves. The duration of continuous Es reflections were decreased upon amplification of oblique sounding frequency. The distributions of duration of reflected signals for meter waves showed sharp curves in the range 200 -- 300 s, representing borderlines between signals reflected from meteoric traces and from Es layer. The filling coefficient for the oblique sounding as well as the Es layer emersion probability for the vertical sounding were shown to undergo daily, seasonal and periodic variations. The daily variations of the filling coefficient of Es signals showed clear-cut maximums at 10 -- 12 and 18 -- 20 hours and minimum at 4 -- 6 hours at all paths in summer time and the maximum at 12 -- 14 hours in winter time. The values of the filling coefficient for Es layer declined with the increase of oblique sounding frequency. The minimal values of the filling coefficient were observed in winter and early spring, while the maximal values were observed from May to August. Provided that the averaged filling coefficient is equal to one in summer, it reaches the level 0,25 in equinox and does not exceed the level 0,12 in winter as evident by the of oblique sounding. The filling coefficient relation to the value of the voltage detection threshold was approximated by power-mode law. The filling coefficients for summer period showed exponential relation with equivalent sounding frequencies. The experimental evidence was generalized in an analytical model. Using this model the averaged Es layer filling coefficients for particular season of the year can be forecasted in case of given sounding frequency, path length, and voltage threshold.
Normative behavioral thresholds for short tone-bursts.
Beattie, R C; Rochverger, I
2001-10-01
Although tone-bursts have been commonly used in auditory brainstem response (ABR) evaluations for many years, national standards describing normal calibration values have not been established. This study was designed to gather normative threshold data to establish a physical reference for tone-burst stimuli that can be reproduced across clinics and laboratories. More specifically, we obtained norms for 3-msec tone-bursts presented at two repetition rates (9.3/sec and 39/sec), two gating functions (Trapezoid and Blackman), and four frequencies (500, 1000, 2000, and 4000 Hz). Our results are specified using three physical references: dB peak sound pressure level, dB peak-to-peak equivalent sound pressure level, and dB SPL (fast meter response, rate = 50 stimuli/sec). These data are offered for consideration when calibrating ABR equipment. The 39/sec stimulus rate yielded tone-burst thresholds that were approximately 3 dB lower than the 9.3/sec rate. The improvement in threshold with increasing stimulus rate may reflect the ability of the auditory system to integrate energy that occurs within a time interval of 200 to 500 msec (temporal integration). The Trapezoid gating function yielded thresholds that averaged 1.4 dB lower than the Blackman function. Although these differences are small and of little clinical importance, the cumulative effects of several instrument and/or procedural variables may yield clinically important differences.
Rodriguez, Amanda I; Thomas, Megan L A; Fitzpatrick, Denis; Janky, Kristen L
Vestibular evoked myogenic potential (VEMP) testing is increasingly utilized in pediatric vestibular evaluations due to its diagnostic capability to identify otolith dysfunction and feasibility of testing. However, there is evidence demonstrating that the high-intensity stimulation level required to elicit a reliable VEMP response causes acoustic trauma in adults. Despite utility of VEMP testing in children, similar findings are unknown. It is hypothesized that increased sound exposure may exist in children because differences in ear-canal volume (ECV) compared with adults, and the effect of stimulus parameters (e.g., signal duration and intensity) will alter exposure levels delivered to a child's ear. The objectives of this study are to (1) measure peak to peak equivalent sound pressure levels (peSPL) in children with normal hearing (CNH) and young adults with normal hearing (ANH) using high-intensity VEMP stimuli, (2) determine the effect of ECV on peSPL and calculate a safe exposure level for VEMP, and (3) assess whether cochlear changes exist after VEMP exposure. This was a 2-phase approach. Fifteen CNH and 12 ANH participated in phase I. Equivalent ECV was measured. In 1 ear, peSPL was recorded for 5 seconds at 105 to 125 dB SPL, in 5-dB increments for 500- and 750-Hz tone bursts. Recorded peSPL values (accounting for stimulus duration) were then used to calculate safe sound energy exposure values for VEMP testing using the 132-dB recommended energy allowance from the 2003 European Union Guidelines. Fifteen CNH and 10 ANH received cervical and ocular VEMP testing in 1 ear in phase II. Subjects completed tympanometry, pre- and postaudiometric threshold testing, distortion product otoacoustic emissions, and questionnaire addressing subjective otologic symptoms to study the effect of VEMP exposure on cochlear function. (1) In response to high-intensity stimulation levels (e.g., 125 dB SPL), CNH had significantly higher peSPL measurements and smaller ECVs compared with ANH. (2) A significant linear relationship between equivalent ECV (as measured by diagnostic tympanometry) and peSPL exists and has an effect on total sound energy exposure level; based on data from phase I, 120 dB SPL was determined to be an acoustically safe stimulation level for testing in children. (3) Using calculated safe stimulation level for VEMP testing, there were no significant effect of VEMP exposure on cochlear function (as measured by audiometric thresholds, distortion product otoacoustic emission amplitude levels, or subjective symptoms) in CNH and ANH. peSPL sound recordings in children's ears are significantly higher (~3 dB) than that in adults in response to high-intensity VEMP stimuli that are commonly practiced. Equivalent ECV contributes to peSPL delivered to the ear during VEMP testing and should be considered to determine safe acoustic VEMP stimulus parameters; children with smaller ECVs are at risk for unsafe sound exposure during routine VEMP testing, and stimuli should not exceed 120 dB SPL. Using 120 dB SPL stimulus level for children during VEMP testing yields no change to cochlear function and reliable VEMP responses.
Absolute auditory threshold: testing the absolute.
Heil, Peter; Matysiak, Artur
2017-11-02
The mechanisms underlying the detection of sounds in quiet, one of the simplest tasks for auditory systems, are debated. Several models proposed to explain the threshold for sounds in quiet and its dependence on sound parameters include a minimum sound intensity ('hard threshold'), below which sound has no effect on the ear. Also, many models are based on the assumption that threshold is mediated by integration of a neural response proportional to sound intensity. Here, we test these ideas. Using an adaptive forced choice procedure, we obtained thresholds of 95 normal-hearing human ears for 18 tones (3.125 kHz carrier) in quiet, each with a different temporal amplitude envelope. Grand-mean thresholds and standard deviations were well described by a probabilistic model according to which sensory events are generated by a Poisson point process with a low rate in the absence, and higher, time-varying rates in the presence, of stimulation. The subject actively evaluates the process and bases the decision on the number of events observed. The sound-driven rate of events is proportional to the temporal amplitude envelope of the bandpass-filtered sound raised to an exponent. We find no evidence for a hard threshold: When the model is extended to include such a threshold, the fit does not improve. Furthermore, we find an exponent of 3, consistent with our previous studies and further challenging models that are based on the assumption of the integration of a neural response that, at threshold sound levels, is directly proportional to sound amplitude or intensity. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Pfiffner, Flurin; Kompis, Martin; Stieger, Christof
2009-10-01
To investigate correlations between preoperative hearing thresholds and postoperative aided thresholds and speech understanding of users of Bone-anchored Hearing Aids (BAHA). Such correlations may be useful to estimate the postoperative outcome with BAHA from preoperative data. Retrospective case review. Tertiary referral center. : Ninety-two adult unilaterally implanted BAHA users in 3 groups: (A) 24 subjects with a unilateral conductive hearing loss, (B) 38 subjects with a bilateral conductive hearing loss, and (C) 30 subjects with single-sided deafness. Preoperative air-conduction and bone-conduction thresholds and 3-month postoperative aided and unaided sound-field thresholds as well as speech understanding using German 2-digit numbers and monosyllabic words were measured and analyzed. Correlation between preoperative air-conduction and bone-conduction thresholds of the better and of the poorer ear and postoperative aided thresholds as well as correlations between gain in sound-field threshold and gain in speech understanding. Aided postoperative sound-field thresholds correlate best with BC threshold of the better ear (correlation coefficients, r2 = 0.237 to 0.419, p = 0.0006 to 0.0064, depending on the group of subjects). Improvements in sound-field threshold correspond to improvements in speech understanding. When estimating expected postoperative aided sound-field thresholds of BAHA users from preoperative hearing thresholds, the BC threshold of the better ear should be used. For the patient groups considered, speech understanding in quiet can be estimated from the improvement in sound-field thresholds.
The hearing threshold of a harbor porpoise (Phocoena phocoena) for impulsive sounds (L).
Kastelein, Ronald A; Gransier, Robin; Hoek, Lean; de Jong, Christ A F
2012-08-01
The distance at which harbor porpoises can hear underwater detonation sounds is unknown, but depends, among other factors, on the hearing threshold of the species for impulsive sounds. Therefore, the underwater hearing threshold of a young harbor porpoise for an impulsive sound, designed to mimic a detonation pulse, was quantified by using a psychophysical technique. The synthetic exponential pulse with a 5 ms time constant was produced and transmitted by an underwater projector in a pool. The resulting underwater sound, though modified by the response of the projection system and by the pool, exhibited the characteristic features of detonation sounds: A zero to peak sound pressure level of at least 30 dB (re 1 s(-1)) higher than the sound exposure level, and a short duration (34 ms). The animal's 50% detection threshold for this impulsive sound occurred at a received unweighted broadband sound exposure level of 60 dB re 1 μPa(2)s. It is shown that the porpoise's audiogram for short-duration tonal signals [Kastelein et al., J. Acoust. Soc. Am. 128, 3211-3222 (2010)] can be used to estimate its hearing threshold for impulsive sounds.
Smartphone threshold audiometry in underserved primary health-care contexts.
Sandström, Josefin; Swanepoel, De Wet; Carel Myburgh, Hermanus; Laurent, Claude
2016-01-01
To validate a calibrated smartphone-based hearing test in a sound booth environment and in primary health-care clinics. A repeated-measure within-subject study design was employed whereby air-conduction hearing thresholds determined by smartphone-based audiometry was compared to conventional audiometry in a sound booth and a primary health-care clinic environment. A total of 94 subjects (mean age 41 years ± 17.6 SD and range 18-88; 64% female) were assessed of whom 64 were tested in the sound booth and 30 within primary health-care clinics without a booth. In the sound booth 63.4% of conventional and smartphone thresholds indicated normal hearing (≤15 dBHL). Conventional thresholds exceeding 15 dB HL corresponded to smartphone thresholds within ≤10 dB in 80.6% of cases with an average threshold difference of -1.6 dB ± 9.9 SD. In primary health-care clinics 13.7% of conventional and smartphone thresholds indicated normal hearing (≤15 dBHL). Conventional thresholds exceeding 15 dBHL corresponded to smartphone thresholds within ≤10 dB in 92.9% of cases with an average threshold difference of -1.0 dB ± 7.1 SD. Accurate air-conduction audiometry can be conducted in a sound booth and without a sound booth in an underserved community health-care clinic using a smartphone.
Zhang, Xiao-Zheng; Bi, Chuan-Xing; Zhang, Yong-Bin; Xu, Liang
2015-05-01
Planar near-field acoustic holography has been successfully extended to reconstruct the sound field in a moving medium, however, the reconstructed field still contains the convection effect that might lead to the wrong identification of sound sources. In order to accurately identify sound sources in a moving medium, a time-domain equivalent source method is developed. In the method, the real source is replaced by a series of time-domain equivalent sources whose strengths are solved iteratively by utilizing the measured pressure and the known convective time-domain Green's function, and time averaging is used to reduce the instability in the iterative solving process. Since these solved equivalent source strengths are independent of the convection effect, they can be used not only to identify sound sources but also to model sound radiations in both moving and static media. Numerical simulations are performed to investigate the influence of noise on the solved equivalent source strengths and the effect of time averaging on reducing the instability, and to demonstrate the advantages of the proposed method on the source identification and sound radiation modeling.
Adams, Karin L; Brazile, William J
2017-02-01
Noise exposure and hearing thresholds of indoor hockey officials of the Western States Hockey League were measured to assess the impact of hockey game noise on hearing sensitivity. Twenty-nine hockey officials who officiated the league in an arena in southeastern Wyoming in October, November, and December 2014 participated in the study. Personal noise dosimetry was conducted to determine if officials were exposed to an equivalent sound pressure level greater than 85 dBA. Hearing thresholds were measured before and after hockey games to determine if a 10 dB or greater temporary threshold shift in hearing occurred. Pure-tone audiometry was conducted in both ears at 500, 1000, 2000, 3000, 4000, 6000, and 8000 Hz. All noise exposures were greater than 85 dBA, with a mean personal noise exposure level of 93 dBA (SD = 2.2), providing 17.7% (SD = 6.3) of the officials' daily noise dose according to the OSHA criteria. Hearing threshold shifts of 10 dB or greater were observed in 86.2% (25/29) of officials, with 36% (9/25) of those threshold shifts equaling 15 dB or greater. The largest proportion of hearing threshold shifts occurred at 4000 Hz, comprising 35.7% of right ear shifts and 31.8% of left ear shifts. The threshold shifts between the pre- and post-game audiometry were statistically significant in the left ear at 500 (p=.019), 2000 (p=.0009), 3000 (p<.0001) and 4000 Hz (p=.0002), and in the right ear at 2000 (p=.0001), 3000 (p=.0001) and 4000 Hz (p<.0001), based on Wilcoxon-ranked sum analysis. Although not statistically significant at alpha = 0.05, logistic regression indicated that with each increase of one dB of equivalent sound pressure measured from personal noise dosimetry, the odds of a ≥ 10 dB TTS were increased in the left ear at 500 (OR=1.33, 95% CI 0.73-2.45), 3000 (OR=1.02, 95% CI 0.68-1.51), 4000 (OR=1.26, 95% CI 0.93-1.71) and 8000 Hz (OR=1.22, 95% CI 0.76-1.94) and in the right ear at 6000 (OR=1.03, 95% CI 0.14-7.84) and 8000 Hz (OR=1.29, 95% CI 0.12-13.83). These findings suggest that indoor hockey officials are exposed to hazardous levels of noise, experience temporary hearing loss after officiating games, and a hearing conservation program is warranted. Further temporary threshold shift research has the potential to identify officials of other sporting events that are at an increased risk of noise-induced hearing loss.
Evaluation of Two Circumaural Earphones for Audiometry.
Smull, Clae C; Madsen, Brandon; Margolis, Robert H
2018-05-08
The Sennheiser HDA 200 earphone, a standard circumaural earphone used in audiometry for many years, is out of production and is replaced by the RadioEar DD450. The Sennheiser HD 280 Pro earphone is a consumer product that has characteristics that may be suitable for audiometry and may be a low-cost alternative to the DD450. The DD450 and HD 280 Pro earphones were compared with the HDA 200 for use in audiometry. RadioEar DD450 and Sennheiser HD 280 Pro earphones were evaluated for reference equivalent threshold sound pressure levels (RETSPLs), ambient-noise attenuation, and occlusion effects. Audiometric thresholds measured on a group of normal-hearing adults were used to determine RETSPLs. Ambient-noise attenuation was determined by measuring the sound pressure in the ear canal produced by a broadband signal from a loudspeaker with and without occlusion by the earphone. Acoustic occlusion effects were determined by measuring the ear-canal sound pressure produced by a bone-conducted source with and without occlusion by the earphone. The results were compared with measurements obtained from the HDA 200 earphone. Audiometric thresholds obtained using the DD450 earphone did not differ from those obtained with the HDA 200 earphones, indicating that the HDA 200 RETSPLs provided in the audiometer standards (ANSI S3.6-2010; ISO 389-8-2004) are transferable to the DD450. New RETSPLs for the HD 280 Pro earphone were determined from the threshold measurements. Ambient-noise attenuation provided by the DD450 was equivalent to the attenuation provided by the HDA 200. The HD 280 Pro provided less ambient-noise attenuation than the other circumaural earphones, but more than the supra-aural earphones commonly used in audiometry. The DD450 produced an occlusion effect 5 dB larger than that of the HDA 200 at 0.25 and 0.5 kHz; both earphones produced negligible occlusion effects at higher frequencies. The HD 280 Pro produced larger occlusion effects in the low frequencies than the other two earphones, with negligible occlusion effects at 1.0 kHz and above. The HDA 200 RETSPLs are transferable to the DD450. Ambient-noise attenuation and occlusion effects are similar for these two earphones. RETSPLs for the HD 280 Pro are provided. The HD 280 Pro has less ambient-noise attenuation and larger occlusion effects than the DD450 but is a viable low-cost alternative.
Sound and vibration sensitivity of VIIIth nerve fibers in the grassfrog, Rana temporaria.
Christensen-Dalsgaard, J; Jørgensen, M B
1996-10-01
We have studied the sound and vibration sensitivity of 164 amphibian papilla fibers in the VIIIth nerve of the grassfrog, Rana temporaria. The VIIIth nerve was exposed using a dorsal approach. The frogs were placed in a natural sitting posture and stimulated by free-field sound. Furthermore, the animals were stimulated with dorso-ventral vibrations, and the sound-induced vertical vibrations in the setup could be canceled by emitting vibrations in antiphase from the vibration exciter. All low-frequency fibers responded to both sound and vibration with sound thresholds from 23 dB SPL and vibration thresholds from 0.02 cm/s2. The sound and vibration sensitivity was compared for each fiber using the offset between the rate-level curves for sound and vibration stimulation as a measure of relative vibration sensitivity. When measured in this way relative vibration sensitivity decreases with frequency from 42 dB at 100 Hz to 25 dB at 400 Hz. Since sound thresholds decrease from 72 dB SPL at 100 Hz to 50 dB SPL at 400 Hz the decrease in relative vibration sensitivity reflects an increase in sound sensitivity with frequency, probably due to enhanced tympanic sensitivity at higher frequencies. In contrast, absolute vibration sensitivity is constant in most of the frequency range studied. Only small effects result from the cancellation of sound-induced vibrations. The reason for this probably is that the maximal induced vibrations in the present setup are 6-10 dB below the fibers' vibration threshold at the threshold for sound. However, these results are only valid for the present physical configuration of the setup and the high vibration-sensitivities of the fibers warrant caution whenever the auditory fibers are stimulated with free-field sound. Thus, the experiments suggest that the low-frequency sound sensitivity is not caused by sound-induced vertical vibrations. Instead, the low-frequency sound sensitivity is either tympanic or mediated through bone conduction or sound-induced pulsations of the lungs.
Kastelein, Ronald A; Wensveen, Paul J; Terhune, John M; de Jong, Christ A F
2011-01-01
Equal-loudness functions describe relationships between the frequencies of sounds and their perceived loudness. This pilot study investigated the possibility of deriving equal-loudness contours based on the assumption that sounds of equal perceived loudness elicit equal reaction times (RTs). During a psychoacoustic underwater hearing study, the responses of two young female harbor seals to tonal signals between 0.125 and 100 kHz were filmed. Frame-by-frame analysis was used to quantify RT (the time between the onset of the sound stimulus and the onset of movement of the seal away from the listening station). Near-threshold equal-latency contours, as surrogates for equal-loudness contours, were estimated from RT-level functions fitted to mean RT data. The closer the received sound pressure level was to the 50% detection hearing threshold, the more slowly the animals reacted to the signal (RT range: 188-982 ms). Equal-latency contours were calculated relative to the RTs shown by each seal at sound levels of 0, 10, and 20 dB above the detection threshold at 1 kHz. Fifty percent detection thresholds are obtained with well-trained subjects actively listening for faint familiar sounds. When calculating audibility ranges of sounds for harbor seals in nature, it may be appropriate to consider levels 20 dB above this threshold.
Nachtigall, Paul E; Supin, Alexander Ya; Estaban, Jose-Antonio; Pacini, Aude F
2016-02-01
Ice-dwelling beluga whales are increasingly being exposed to anthropogenic loud sounds. Beluga's hearing sensitivity measured during a warning sound just preceding a loud sound was tested using pip-train stimuli and auditory evoked potential recording. When the test/warning stimulus with a frequency of 32 or 45 kHz preceded the loud sound with a frequency of 32 kHz and a sound pressure level of 153 dB re 1 μPa, 2 s, hearing thresholds before the loud sound increased relative to the baseline. The threshold increased up to 15 dB for the test frequency of 45 kHz and up to 13 dB for the test frequency of 32 kHz. These threshold increases were observed during two sessions of 36 trials each. Extinction tests revealed no change during three experimental sessions followed by a jump-like return to baseline thresholds. The low exposure level producing the hearing-dampening effect (156 dB re 1 µPa(2)s in each trial), and the manner of extinction, may be considered as evidence that the observed hearing threshold increases were a demonstration of conditioned dampening of hearing when the whale anticipated the quick appearance of a loud sound in the same way demonstrated in the false killer whale and bottlenose dolphin.
NASA Astrophysics Data System (ADS)
Finneran, James J.; Carder, Donald A.; Ridgway, Sam H.
2002-01-01
The relative contributions of acoustic pressure and particle velocity to the low-frequency, underwater hearing abilities of the bottlenose dolphin (Tursiops truncatus) and white whale (Delphinapterus leucas) were investigated by measuring (masked) hearing thresholds while manipulating the relationship between the pressure and velocity. This was accomplished by varying the distance within the near field of a single underwater sound projector (experiment I) and using two underwater sound projectors and an active sound control system (experiment II). The results of experiment I showed no significant change in pressure thresholds as the distance between the subject and the sound source was changed. In contrast, velocity thresholds tended to increase and intensity thresholds tended to decrease as the source distance decreased. These data suggest that acoustic pressure is a better indicator of threshold, compared to particle velocity or mean active intensity, in the subjects tested. Interpretation of the results of experiment II (the active sound control system) was difficult because of complex acoustic conditions and the unknown effects of the subject on the generated acoustic field; however, these data also tend to support the results of experiment I and suggest that odontocete thresholds should be reported in units of acoustic pressure, rather than intensity.
Development and Current Status of the “Cambridge” Loudness Models
2014-01-01
This article reviews the evolution of a series of models of loudness developed in Cambridge, UK. The first model, applicable to stationary sounds, was based on modifications of the model developed by Zwicker, including the introduction of a filter to allow for the effects of transfer of sound through the outer and middle ear prior to the calculation of an excitation pattern, and changes in the way that the excitation pattern was calculated. Later, modifications were introduced to the assumed middle-ear transfer function and to the way that specific loudness was calculated from excitation level. These modifications led to a finite calculated loudness at absolute threshold, which made it possible to predict accurately the absolute thresholds of broadband and narrowband sounds, based on the assumption that the absolute threshold corresponds to a fixed small loudness. The model was also modified to give predictions of partial loudness—the loudness of one sound in the presence of another. This allowed predictions of masked thresholds based on the assumption that the masked threshold corresponds to a fixed small partial loudness. Versions of the model for time-varying sounds were developed, which allowed prediction of the masked threshold of any sound in a background of any other sound. More recent extensions incorporate binaural processing to account for the summation of loudness across ears. In parallel, versions of the model for predicting loudness for hearing-impaired ears have been developed and have been applied to the development of methods for fitting multichannel compression hearing aids. PMID:25315375
In-Air Evoked Potential Audiometry of Grey Seals (Halichoerus grypus) from the North and Baltic Seas
Ruser, Andreas; Dähne, Michael; Sundermeyer, Janne; Lucke, Klaus; Houser, Dorian S.; Finneran, James J.; Driver, Jörg; Pawliczka, Iwona; Rosenberger, Tanja; Siebert, Ursula
2014-01-01
In-air anthropogenic sound has the potential to affect grey seal (Halichoerus grypus) behaviour and interfere with acoustic communication. In this study, a new method was used to deliver acoustic signals to grey seals as part of an in-air hearing assessment. Using in-ear headphones with adapted ear inserts allowed for the measurement of auditory brainstem responses (ABR) on sedated grey seals exposed to 5-cycle (2-1-2) tone pips. Thresholds were measured at 10 frequencies between 1–20 kHz. Measurements were made using subcutaneous electrodes on wild seals from the Baltic and North Seas. Thresholds were determined by both visual and statistical approaches (single point F-test) and good agreement was obtained between the results using both methods. The mean auditory thresholds were ≤40 dB re 20 µPa peak equivalent sound pressure level (peSPL) between 4–20 kHz and showed similar patterns to in-air behavioural hearing tests of other phocid seals between 3 and 20 kHz. Below 3 kHz, a steep reduction in hearing sensitivity was observed, which differed from the rate of decline in sensitivity obtained in behavioural studies on other phocids. Differences in the rate of decline may reflect influence of the ear inserts on the ability to reliably transmit lower frequencies or interference from the structure of the distal end of the ear canal. PMID:24632891
Kuhn, Pierre; Zores, Claire; Pebayle, Thierry; Hoeft, Alain; Langlet, Claire; Escande, Benoît; Astruc, Dominique; Dufour, André
2012-04-01
Very early preterm infants (VPIs) are exposed to unpredictable noise in neonatal intensive care units. Their ability to perceive moderate acoustic environmental changes has not been fully investigated. Physiological values of the 598 isolated sound peaks (SPs) that were 5-10 and 10-15 dB slow-response A (dBA) above background noise levels and that occurred during infants' sleep varied significantly, indicating that VPIs detect them. Exposure to 10-15 dBA SPs during active sleep significantly increased mean heart rate and decreased mean respiratory rate and mean systemic and cerebral oxygen saturations relative to baseline. VPIs are sensitive to changes in their nosocomial acoustic environment, with a minimal signal-to-noise ratio (SNR) threshold of 5-10 dBA. These acoustic changes can alter their well-being. In this observational study, we evaluated their differential auditory sensitivity to sound-pressure level (SPL) increments below 70-75 dBA equivalent continuous level in their incubators. Environmental (SPL and audio recording), physiological, cerebral, and behavioral data were prospectively collected over 10 h in 26 VPIs (GA 28 (26-31) wk). SPs emerging from background noise levels were identified and newborns' arousal states at the time of SPs were determined. Changes in parameters were compared over 5-s periods between baseline and the 40 s following the SPs depending on their SNR thresholds above background noise.
Underwater temporary threshold shift in pinnipeds: effects of noise level and duration.
Kastak, David; Southall, Brandon L; Schusterman, Ronald J; Kastak, Colleen Reichmuth
2005-11-01
Behavioral psychophysical techniques were used to evaluate the residual effects of underwater noise on the hearing sensitivity of three pinnipeds: a California sea lion (Zalophus californianus), a harbor seal (Phoca vitulina), and a northern elephant seal (Mirounga angustirostris). Temporary threshold shift (TTS), defined as the difference between auditory thresholds obtained before and after noise exposure, was assessed. The subjects were exposed to octave-band noise centered at 2500 Hz at two sound pressure levels: 80 and 95 dB SL (re: auditory threshold at 2500 Hz). Noise exposure durations were 22, 25, and 50 min. Threshold shifts were assessed at 2500 and 3530 Hz. Mean threshold shifts ranged from 2.9-12.2 dB. Full recovery of auditory sensitivity occurred within 24 h of noise exposure. Control sequences, comprising sham noise exposures, did not result in significant mean threshold shifts for any subject. Threshold shift magnitudes increased with increasing noise sound exposure level (SEL) for two of the three subjects. The results underscore the importance of including sound exposure metrics (incorporating sound pressure level and exposure duration) in order to fully assess the effects of noise on marine mammal hearing.
Using speed of sound imaging to characterize breast density
Sak, Mark; Duric, Neb; Littrup, Peter; Bey-Knight, Lisa; Ali, Haythem; Vallieres, Patricia; Sherman, Mark E.; Gierach, Gretchen L.
2017-01-01
A population of 165 women with negative mammographic screens also received an ultrasound tomography (UST) exam at the Karmanos Cancer Institute (KCI) in Detroit, MI. Standard statistical techniques were employed to measure the associations between the various mammographic and UST related density measures and various participant characteristics such as age, weight and height. The Mammographic percent density (MPD) was found to have similar strength associations with UST mean sound speed (Spearman coefficient, rs = 0.722, p < 0.001) and UST median sound speed (rs = 0.737, p < 0.001). Both were stronger than the associations between MPD with two separate measures of UST percent density, a k-means (rs = 0.568, p < 0.001) or a threshold (rs = 0.715, p < 0.001) measure. Segmentation of the UST sound speed images into dense and non-dense volumes showed weak to moderate associations with the mammographically equivalent measures. Relationships were found to be inversely and weakly associated between age and the UST mean sound speed (rs = −0.239, p = 0.002), UST median sound speed (rs = −0.226, p= 0.004) and MPD (rs = −0.204, p= 0.008). Relationships were found to be inversely and moderately associated between BMI and the UST mean sound speed (rs = −0.429, p < 0.001), UST median sound speed (rs = −0.447, p < 0.001) and MPD (rs = −0.489, p < 0.001). The results confirm and strengthen findings presented in previous work indicating that UST sound speed imaging yields viable markers of breast density in a manner consistent with mammography, the current clinical standard. These results lay the groundwork for further studies to assess the role of sound speed imaging in risk prediction. PMID:27692872
Algorithm Development for a Real-Time Military Noise Monitor
2006-03-24
Duration ESLM Enhanced Sound Level Meter ERDC-CERL Engineer Research and Development Center/Construction Engineering Research Laboratory FFT...Fast Fourier Transform FTIG Fort Indiantown Gap Kurt Kurtosis LD Larson Davis Leq Equivalent Sound Level L8eq 8-hr Equivalent...Sound Level Lpk Peak Sound Level m Spectral Slope MCBCL Marine Corps Base Camp Lejeune Neg Number of negative samples NI National
Position-dependent hearing in three species of bushcrickets (Tettigoniidae, Orthoptera)
Lakes-Harlan, Reinhard; Scherberich, Jan
2015-01-01
A primary task of auditory systems is the localization of sound sources in space. Sound source localization in azimuth is usually based on temporal or intensity differences of sounds between the bilaterally arranged ears. In mammals, localization in elevation is possible by transfer functions at the ear, especially the pinnae. Although insects are able to locate sound sources, little attention is given to the mechanisms of acoustic orientation to elevated positions. Here we comparatively analyse the peripheral hearing thresholds of three species of bushcrickets in respect to sound source positions in space. The hearing thresholds across frequencies depend on the location of a sound source in the three-dimensional hearing space in front of the animal. Thresholds differ for different azimuthal positions and for different positions in elevation. This position-dependent frequency tuning is species specific. Largest differences in thresholds between positions are found in Ancylecha fenestrata. Correspondingly, A. fenestrata has a rather complex ear morphology including cuticular folds covering the anterior tympanal membrane. The position-dependent tuning might contribute to sound source localization in the habitats. Acoustic orientation might be a selective factor for the evolution of morphological structures at the bushcricket ear and, speculatively, even for frequency fractioning in the ear. PMID:26543574
Position-dependent hearing in three species of bushcrickets (Tettigoniidae, Orthoptera).
Lakes-Harlan, Reinhard; Scherberich, Jan
2015-06-01
A primary task of auditory systems is the localization of sound sources in space. Sound source localization in azimuth is usually based on temporal or intensity differences of sounds between the bilaterally arranged ears. In mammals, localization in elevation is possible by transfer functions at the ear, especially the pinnae. Although insects are able to locate sound sources, little attention is given to the mechanisms of acoustic orientation to elevated positions. Here we comparatively analyse the peripheral hearing thresholds of three species of bushcrickets in respect to sound source positions in space. The hearing thresholds across frequencies depend on the location of a sound source in the three-dimensional hearing space in front of the animal. Thresholds differ for different azimuthal positions and for different positions in elevation. This position-dependent frequency tuning is species specific. Largest differences in thresholds between positions are found in Ancylecha fenestrata. Correspondingly, A. fenestrata has a rather complex ear morphology including cuticular folds covering the anterior tympanal membrane. The position-dependent tuning might contribute to sound source localization in the habitats. Acoustic orientation might be a selective factor for the evolution of morphological structures at the bushcricket ear and, speculatively, even for frequency fractioning in the ear.
Ekström, Seth-Reino; Borg, Erik
2011-01-01
The masking effect of a piano composition, played at different speeds and in different octaves, on speech-perception thresholds was investigated in 15 normal-hearing and 14 moderately-hearing-impaired subjects. Running speech (just follow conversation, JFC) testing and use of hearing aids increased the everyday validity of the findings. A comparison was made with standard audiometric noises [International Collegium of Rehabilitative Audiology (ICRA) noise and speech spectrum-filtered noise (SPN)]. All masking sounds, music or noise, were presented at the same equivalent sound level (50 dBA). The results showed a significant effect of piano performance speed and octave (P<.01). Low octave and fast tempo had the largest effect; and high octave and slow tempo, the smallest. Music had a lower masking effect than did ICRA noise with two or six speakers at normal vocal effort (P<.01) and SPN (P<.05). Subjects with hearing loss had higher masked thresholds than the normal-hearing subjects (P<.01), but there were smaller differences between masking conditions (P<.01). It is pointed out that music offers an interesting opportunity for studying masking under realistic conditions, where spectral and temporal features can be varied independently. The results have implications for composing music with vocal parts, designing acoustic environments and creating a balance between speech perception and privacy in social settings.
Comparison of auditory stream segregation in sighted and early blind individuals.
Boroujeni, Fatemeh Moghadasi; Heidari, Fatemeh; Rouzbahani, Masoumeh; Kamali, Mohammad
2017-01-18
An important characteristic of the auditory system is the capacity to analyze complex sounds and make decisions on the source of the constituent parts of these sounds. Blind individuals compensate for the lack of visual information by an increase input from other sensory modalities, including increased auditory information. The purpose of the current study was to compare the fission boundary (FB) threshold of sighted and early blind individuals through spectral aspects using a psychoacoustic auditory stream segregation (ASS) test. This study was conducted on 16 sighted and 16 early blind adult individuals. The applied stimuli were presented sequentially as the pure tones A and B and as a triplet ABA-ABA pattern at the intensity of 40dBSL. The A tone frequency was selected as the basis at values of 500, 1000, and 2000Hz. The B tone was presented with the difference of a 4-100% above the basis tone frequency. Blind individuals had significantly lower FB thresholds than sighted people. FB was independent of the frequency of the tone A when expressed as the difference in the number of equivalent rectangular bandwidths (ERBs). Early blindness may increase perceptual separation of the acoustic stimuli to form accurate representations of the world. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Heeringa, A N; van Dijk, P
2014-06-01
Excessive noise exposure is known to produce an auditory threshold shift, which can be permanent or transient in nature. Recent studies showed that noise-induced temporary threshold shifts are associated with loss of synaptic connections to the inner hair cells and with cochlear nerve degeneration, which is reflected in a decreased amplitude of wave I of the auditory brainstem response (ABR). This suggests that, despite normal auditory thresholds, central auditory processing may be abnormal. We recorded changes in central auditory processing following a sound-induced temporary threshold shift. Anesthetized guinea pigs were exposed for 1 h to a pure tone of 11 kHz (124 dB sound pressure level). Hearing thresholds, amplitudes of ABR waves I and IV, and spontaneous and tone-evoked firing rates in the inferior colliculus (IC) were assessed immediately, one week, two weeks, and four weeks post exposure. Hearing thresholds were elevated immediately following overexposure, but recovered within one week. The amplitude of the ABR wave I was decreased in all sound-exposed animals for all test periods. In contrast, the ABR wave IV amplitude was only decreased immediately after overexposure and recovered within a week. The proportion of IC units that show inhibitory responses to pure tones decreased substantially up to two weeks after overexposure, especially when stimulated with high frequencies. The proportion of excitatory responses to low frequencies was increased. Spontaneous activity was unaffected by the overexposure. Despite rapid normalization of auditory thresholds, our results suggest an increased central gain following sound exposure and an abnormal balance between excitatory and inhibitory responses in the midbrain up to two weeks after overexposure. These findings may be associated with hyperacusis after a sound-induced temporary threshold shift. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Almeida, Andre; George, David; Smith, John; Wolfe, Joe
2013-09-01
Using an automated clarinet playing system, the frequency f, sound level L, and spectral characteristics are measured as functions of blowing pressure P and the force F applied by the mechanical lip at different places on the reed. The playing regime on the (P,F) plane lies below an extinction line F(P) with a negative slope of a few square centimeters and above a pressure threshold with a more negative slope. Lower values of F and P can produce squeaks. Over much of the playing regime, lines of equal frequency have negative slope. This is qualitatively consistent with passive reed behavior: Increasing F or P gradually closes the reed, reducing its equivalent acoustic compliance, which increases the frequency of the peaks of the parallel impedance of bore and reed. High P and low F produce the highest sound levels and stronger higher harmonics. At low P, sound level can be increased at constant frequency by increasing P while simultaneously decreasing F. At high P, where lines of equal f and of equal L are nearly parallel, this compensation is less effective. Applying F further from the mouthpiece tip moves the playing regime to higher F and P, as does a stiffer reed.
Effect of gap detection threshold on consistency of speech in children with speech sound disorder.
Sayyahi, Fateme; Soleymani, Zahra; Akbari, Mohammad; Bijankhan, Mahmood; Dolatshahi, Behrooz
2017-02-01
The present study examined the relationship between gap detection threshold and speech error consistency in children with speech sound disorder. The participants were children five to six years of age who were categorized into three groups of typical speech, consistent speech disorder (CSD) and inconsistent speech disorder (ISD).The phonetic gap detection threshold test was used for this study, which is a valid test comprised six syllables with inter-stimulus intervals between 20-300ms. The participants were asked to listen to the recorded stimuli three times and indicate whether they heard one or two sounds. There was no significant difference between the typical and CSD groups (p=0.55), but there were significant differences in performance between the ISD and CSD groups and the ISD and typical groups (p=0.00). The ISD group discriminated between speech sounds at a higher threshold. Children with inconsistent speech errors could not distinguish speech sounds during time-limited phonetic discrimination. It is suggested that inconsistency in speech is a representation of inconsistency in auditory perception, which causes by high gap detection threshold. Copyright © 2016 Elsevier Ltd. All rights reserved.
Noise exposure estimates of urban MP3 player users.
Levey, Sandra; Levey, Tania; Fligor, Brian J
2011-02-01
To examine the sound level and duration of use of personal listening devices (PLDs) by 189 college students, ages 18-53 years, as they entered a New York City college campus, to determine whether noise exposure from PLDs was in excess of recommended exposure limits and what factors might influence exposure. Free-field equivalent sound levels from PLD headphones were measured on a mannequin with a calibrated sound level meter. Participants reported demographic information, whether they had just come off the subway, the type of PLD and earphones used, and duration per day and days per week they used their PLDs. Based on measured free-field equivalent sound levels from PLD headphones and the reported PLD use, per day 58.2% of participants exceeded 85 dB A-weighted 8-hr equivalent sound levels (L(Aeq)), and per week 51.9% exceeded 85 dB A-weighted 40-hr equivalent continuous sound levels (L(Awkn)). The majority of PLD users exceeded recommended sound exposure limits, suggesting that they were at increased risk for noise-induced hearing loss. Analyses of the demographics of these participants and mode of transportation to campus failed to indicate any particular gender differences in PLD use or in mode of transportation influencing sound exposure.
Cochlear neuropathy and the coding of supra-threshold sound.
Bharadwaj, Hari M; Verhulst, Sarah; Shaheen, Luke; Liberman, M Charles; Shinn-Cunningham, Barbara G
2014-01-01
Many listeners with hearing thresholds within the clinically normal range nonetheless complain of difficulty hearing in everyday settings and understanding speech in noise. Converging evidence from human and animal studies points to one potential source of such difficulties: differences in the fidelity with which supra-threshold sound is encoded in the early portions of the auditory pathway. Measures of auditory subcortical steady-state responses (SSSRs) in humans and animals support the idea that the temporal precision of the early auditory representation can be poor even when hearing thresholds are normal. In humans with normal hearing thresholds (NHTs), paradigms that require listeners to make use of the detailed spectro-temporal structure of supra-threshold sound, such as selective attention and discrimination of frequency modulation (FM), reveal individual differences that correlate with subcortical temporal coding precision. Animal studies show that noise exposure and aging can cause a loss of a large percentage of auditory nerve fibers (ANFs) without any significant change in measured audiograms. Here, we argue that cochlear neuropathy may reduce encoding precision of supra-threshold sound, and that this manifests both behaviorally and in SSSRs in humans. Furthermore, recent studies suggest that noise-induced neuropathy may be selective for higher-threshold, lower-spontaneous-rate nerve fibers. Based on our hypothesis, we suggest some approaches that may yield particularly sensitive, objective measures of supra-threshold coding deficits that arise due to neuropathy. Finally, we comment on the potential clinical significance of these ideas and identify areas for future investigation.
Swanepoel, De Wet; Matthysen, Cornelia; Eikelboom, Robert H; Clark, Jackie L; Hall, James W
2015-01-01
Accessibility of audiometry is hindered by the cost of sound booths and shortage of hearing health personnel. This study investigated the validity of an automated mobile diagnostic audiometer with increased attenuation and real-time noise monitoring for clinical testing outside a sound booth. Attenuation characteristics and reference ambient noise levels for the computer-based audiometer (KUDUwave) was evaluated alongside the validity of environmental noise monitoring. Clinical validity was determined by comparing air- and bone-conduction thresholds obtained inside and outside the sound booth (23 subjects). Twenty-three normal-hearing subjects (age range, 20-75 years; average age 35.5) and a sub group of 11 subjects to establish test-retest reliability. Improved passive attenuation and valid environmental noise monitoring was demonstrated. Clinically, air-conduction thresholds inside and outside the sound booth, corresponded within 5 dB or less > 90% of instances (mean absolute difference 3.3 ± 3.2 SD). Bone conduction thresholds corresponded within 5 dB or less in 80% of comparisons between test environments, with a mean absolute difference of 4.6 dB (3.7 SD). Threshold differences were not statistically significant. Mean absolute test-retest differences outside the sound booth was similar to those in the booth. Diagnostic pure-tone audiometry outside a sound booth, using automated testing, improved passive attenuation, and real-time environmental noise monitoring demonstrated reliable hearing assessments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 85 dBA, or equivalently a dose of 50%, integrating all sound levels from 80 dBA to at least 130 dBA... Protection Level. A TWA8 of 105 dBA, or equivalently, a dose of 800% of that permitted by the standard, integrating all sound levels from 90 dBA to at least 140 dBA. Exchange rate. The amount of increase in sound...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 85 dBA, or equivalently a dose of 50%, integrating all sound levels from 80 dBA to at least 130 dBA... Protection Level. A TWA8 of 105 dBA, or equivalently, a dose of 800% of that permitted by the standard, integrating all sound levels from 90 dBA to at least 140 dBA. Exchange rate. The amount of increase in sound...
Auditory steady state response in sound field.
Hernández-Pérez, H; Torres-Fortuny, A
2013-02-01
Physiological and behavioral responses were compared in normal-hearing subjects via analyses of the auditory steady-state response (ASSR) and conventional audiometry under sound field conditions. The auditory stimuli, presented through a loudspeaker, consisted of four carrier tones (500, 1000, 2000, and 4000 Hz), presented singly for behavioral testing but combined (multiple frequency technique), to estimate thresholds using the ASSR. Twenty normal-hearing adults were examined. The average differences between the physiological and behavioral thresholds were between 17 and 22 dB HL. The Spearman rank correlation between ASSR and behavioral thresholds was significant for all frequencies (p < 0.05). Significant differences were found in the ASSR amplitude among frequencies, and strong correlations between the ASSR amplitude and the stimulus level (p < 0.05). The ASSR in sound field testing was found to yield hearing threshold estimates deemed to be reasonably well correlated with behaviorally assessed thresholds.
Safety of an intra-oral hearing device utilizing a split-mouth research design.
Miller, Ross; Hujoel, Philippe; Murray, Michael; Popelka, Gerald R
2011-01-01
The auditory deficits of Single Sided Deafness (SSD) can be treated effectively with a novel device, SoundBite, that delivers sound by applying imperceptible vibratory signals to the teeth (hereafter referred to as an intra-oral hearing device). The intra-oral hearing device is placed around two maxillary teeth and is similar to a small partial denture or retainer. The goal of this study was to report how this removable hearing device affects the oral structures. Twenty-two SSD patients wearing an intra-oral hearing device were enrolled in a prospective study for six months. Differences (delta) between the device-anchoring teeth and the equivalent contralateral non-device teeth were evaluated with four dental parameters using a paired t-test. Hearing thresholds were evaluated as a function of alveolar bone support using linear regression. Compared to the non-device teeth, the hearing device teeth did not exhibit any increased recession (delta = 0.1 mm, p-value = 0.48), increased pocket depth (delta = 0.0 mm, p-value = 0.48), increased root resorption (delta = 4%, p-value = 0.43), or increased alveolar bone loss (delta = 0.0 %, p-value = 0.43). There was no association between the amount of alveolar support and hearing thresholds (delta = 0.2, p-value = 0.34). The intra-oral component of the hearing device did not adversely affect the dental structures of the subjects in this trial.
NASA Astrophysics Data System (ADS)
Jin, Zhongkun; Yin, Yao; Liu, Bilong
2016-03-01
The finite element method is often used to investigate the sound absorption of anechoic coating backed with orthogonally rib-stiffened plate. Since the anechoic coating contains cavities, the number of grid nodes of a periodic unit cell is usually large. An equivalent modulus method is proposed to reduce the large amount of nodes by calculating an equivalent homogeneous layer. Applications of this method in several models show that the method can well predict the sound absorption coefficient of such structure in a wide frequency range. Based on the simulation results, the sound absorption performance of such structure and the influences of different backings on the first absorption peak are also discussed.
Poletti, Mark A; Betlehem, Terence; Abhayapala, Thushara D
2014-07-01
Higher order sound sources of Nth order can radiate sound with 2N + 1 orthogonal radiation patterns, which can be represented as phase modes or, equivalently, amplitude modes. This paper shows that each phase mode response produces a spiral wave front with a different spiral rate, and therefore a different direction of arrival of sound. Hence, for a given receiver position a higher order source is equivalent to a linear array of 2N + 1 monopole sources. This interpretation suggests performance similar to a circular array of higher order sources can be produced by an array of sources, each of which consists of a line array having monopoles at the apparent source locations of the corresponding phase modes. Simulations of higher order arrays and arrays of equivalent line sources are presented. It is shown that the interior fields produced by the two arrays are essentially the same, but that the exterior fields differ because the higher order sources produces different equivalent source locations for field positions outside the array. This work provides an explanation of the fact that an array of L Nth order sources can reproduce sound fields whose accuracy approaches the performance of (2N + 1)L monopoles.
Finneran, James J; Schlundt, Carolyn E
2007-07-01
Studies of underwater hearing are often hampered by the behavior of sound waves in small experimental tanks. At lower frequencies, tank dimensions are often not sufficient for free field conditions, resulting in large spatial variations of sound pressure. These effects may be mitigated somewhat by increasing the frequency bandwidth of the sound stimulus, so effects of multipath interference average out over many frequencies. In this study, acoustic fields and bottlenose dolphin (Tursiops truncatus) hearing thresholds were compared for pure tone and frequency modulated signals. Experiments were conducted in a vinyl-walled, seawater-filled pool approximately 3.7 x 6 x 1.5 m. Acoustic signals were pure tone and linear and sinusoidal frequency modulated tones with bandwidths/modulation depths of 1%, 2%, 5%, 10%, and 20%. Thirteen center frequencies were tested between 1 and 100 kHz. Acoustic fields were measured (without the dolphin present) at three water depths over a 60 x 65 cm grid with a 5-cm spacing. Hearing thresholds were measured using a behavioral response paradigm and up/down staircase technique. The use of FM signals significantly improved the sound field without substantially affecting the measured hearing thresholds.
Neoprene wet-suit hood affects low-frequency underwater hearing thresholds.
Fothergill, David M; Sims, John R; Curley, Michael D
2004-05-01
Psychophysical measures of wet-suit hood sound attenuation are needed to provide the diving community with guidance on protection from underwater sound. Underwater hearing thresholds were obtained from 15 male and 5 female recreational divers with and without a 3-mm thick wet-suit hood. Dives were conducted at a depth of 1 m in a large quiet anechoic pool. Thresholds were determined using a two-interval forced-choice procedure with a 0.71 probability of positive response at convergence. A 1-s pure tone was presented with a 20-ms rise and fall time at 100, 200, 250, 300, 400, and 500 Hz. Without a wet-suit hood, mean thresholds decreased from 99 dB re 1 microPa at 100 Hz to 85 dB at 500 Hz. Thresholds were statistically similar at 100 to 300 Hz with and without the wet-suit hood, but were significantly increased at 400 and 500 Hz with the hood (p < 0.001). In conclusion, at shallow depths, a 3-mm neoprene wet-suit hood attenuates underwater sound by approximately 10 dB for frequencies between 400 Hz and 500 Hz. At frequencies below 400 Hz, a 3-mm neoprene wet-suit hood offers no sound protection.
Underwater hearing and sound localization with and without an air interface.
Shupak, Avi; Sharoni, Zohara; Yanir, Yoav; Keynan, Yoav; Alfie, Yechezkel; Halpern, Pinchas
2005-01-01
Underwater hearing acuity and sound localization are improved by the presence of an air interface around the pinnae and inside the external ear canals. Hearing threshold and the ability to localize sound sources are reduced underwater. The resonance frequency of the external ear is lowered when the external ear canal is filled with water, and the impedance-matching ability of the middle ear is significantly reduced due to elevation of the ambient pressure, the water-mass load on the tympanic membrane, and the addition of a fluid-air interface during submersion. Sound lateralization on land is largely explained by the mechanisms of interaural intensity differences and interaural temporal or phase differences. During submersion, these differences are largely lost due to the increase in underwater sound velocity and cancellation of the head's acoustic shadow effect because of the similarity between the impedance of the skull and the surrounding water. Ten scuba divers wearing a regular opaque face mask or an opaque ProEar 2000 (Safe Dive, Ltd., Hofit, Israel) mask that enables the presence of air at ambient pressure in and around the ear made a dive to a depth of 3 m in the open sea. Four underwater speakers arranged on the horizontal plane at 90-degree intervals and at a distance of 5 m from the diver were used for testing pure-tone hearing thresholds (PTHT), the reception threshold for the recorded sound of a rubber-boat engine, and sound localization. For sound localization, the sound of the rubber boat's engine was randomly delivered by one speaker at a time at 40 dB HL above the recorded sound of a rubber-boat engine, and the diver was asked to point to the sound source. The azimuth was measured by the diver's companion using a navigation board. Underwater PTHT with both masks were significantly higher for frequencies of 250 to 6000 Hz when compared with the thresholds on land (p <0.0001). No differences were found in the PTHT or the reception threshold for the recorded sound of a rubber-boat engine for dry or wet ear conditions. There was no difference in the sound localization error between the regular mask and the ProEar 2000 mask. The presence of air around the pinna and inside the external ear canal did not improve underwater hearing sensitivity or sound localization. These results support the argument that bone conduction plays the main role in underwater hearing.
[The health condition of forest workers exposed to noise and vibration produced by chain saws].
Malinowska-Borowska, Jolanta; Socholik, Violetta; Harazin, Barbara
2012-01-01
Lumberjacks' working conditions are difficult due to the presence of numerous occupational hazards. Physical factors that pose a health risk are noise and vibration produced by chain saws. Excessive exposure of lumberjacks to noise and vibration can lead to the development of hand-arm vibration syndrome and hearing loss. The aim of the work was to analyze the health condition of forestry workers exposed to occupational physical hazards. A preliminary, questionnaire-based assessment of health status was conducted in 22 chain saw operators. In a group of 15 forestry workers audiometry, vibrotactile perception thresholds and cold provocation test were performed. X-ray diagnostic imaging of upper limbs was also done. At the same time noise and vibration produced by chain saws used in forestry was measured. Vascular or neurological disorders were found in nearly half of tested workers with seniority from 2 to 20 years; 40% of the surveyed was diagnosed with hearing impairment. An 8-hour energy equivalent vibration level measured on chain saws was 4.6 m/s2. An 8-hour equivalent sound pressure level was 99.1 dB(A). The threshold limit values for noise and vibration are exceeded at woodcutters' posts. There are changes in lumberjacks' health resulting from exposure to harmful physical agents. Preventive actions are urgently needed to be addressed, especially to people employed in single-handed forestry companies.
Cartilage conduction is characterized by vibrations of the cartilaginous portion of the ear canal.
Nishimura, Tadashi; Hosoi, Hiroshi; Saito, Osamu; Miyamae, Ryosuke; Shimokura, Ryota; Yamanaka, Toshiaki; Kitahara, Tadashi; Levitt, Harry
2015-01-01
Cartilage conduction (CC) is a new form of sound transmission which is induced by a transducer being placed on the aural cartilage. Although the conventional forms of sound transmission to the cochlea are classified into air or bone conduction (AC or BC), previous study demonstrates that CC is not classified into AC or BC (Laryngoscope 124: 1214-1219). Next interesting issue is whether CC is a hybrid of AC and BC. Seven volunteers with normal hearing participated in this experiment. The threshold-shifts by water injection in the ear canal were measured. AC, BC, and CC thresholds at 0.5-4 kHz were measured in the 0%-, 40%-, and 80%-water injection conditions. In addition, CC thresholds were also measured for the 20%-, 60%-, 100%-, and overflowing-water injection conditions. The contributions of the vibrations of the cartilaginous portion were evaluated by the threshold-shifts. For AC and BC, the threshold-shifts by the water injection were 22.6-53.3 dB and within 14.9 dB at the frequency of 0.5-4 kHz, respectively. For CC, when the water was filled within the bony portion, the thresholds were elevated to the same degree as AC. When the water was additionally injected to reach the cartilaginous portion, the thresholds at 0.5 and 1 kHz dramatically decreased by 27.4 and 27.5 dB, respectively. In addition, despite blocking AC by the injected water, the CC thresholds in force level were remarkably lower than those for BC. The vibration of the cartilaginous portion contributes to the sound transmission, particularly in the low frequency range. Although the airborne sound is radiated into the ear canal in both BC and CC, the mechanism underlying its generation is different between them. CC generates airborne sound in the canal more efficiently than BC. The current findings suggest that CC is not a hybrid of AC and BC.
Cartilage Conduction Is Characterized by Vibrations of the Cartilaginous Portion of the Ear Canal
Nishimura, Tadashi; Hosoi, Hiroshi; Saito, Osamu; Miyamae, Ryosuke; Shimokura, Ryota; Yamanaka, Toshiaki; Kitahara, Tadashi; Levitt, Harry
2015-01-01
Cartilage conduction (CC) is a new form of sound transmission which is induced by a transducer being placed on the aural cartilage. Although the conventional forms of sound transmission to the cochlea are classified into air or bone conduction (AC or BC), previous study demonstrates that CC is not classified into AC or BC (Laryngoscope 124: 1214–1219). Next interesting issue is whether CC is a hybrid of AC and BC. Seven volunteers with normal hearing participated in this experiment. The threshold-shifts by water injection in the ear canal were measured. AC, BC, and CC thresholds at 0.5–4 kHz were measured in the 0%-, 40%-, and 80%-water injection conditions. In addition, CC thresholds were also measured for the 20%-, 60%-, 100%-, and overflowing-water injection conditions. The contributions of the vibrations of the cartilaginous portion were evaluated by the threshold-shifts. For AC and BC, the threshold-shifts by the water injection were 22.6–53.3 dB and within 14.9 dB at the frequency of 0.5–4 kHz, respectively. For CC, when the water was filled within the bony portion, the thresholds were elevated to the same degree as AC. When the water was additionally injected to reach the cartilaginous portion, the thresholds at 0.5 and 1 kHz dramatically decreased by 27.4 and 27.5 dB, respectively. In addition, despite blocking AC by the injected water, the CC thresholds in force level were remarkably lower than those for BC. The vibration of the cartilaginous portion contributes to the sound transmission, particularly in the low frequency range. Although the airborne sound is radiated into the ear canal in both BC and CC, the mechanism underlying its generation is different between them. CC generates airborne sound in the canal more efficiently than BC. The current findings suggest that CC is not a hybrid of AC and BC. PMID:25768088
Spatial traffic noise pollution assessment - A case study.
Monazzam, Mohammad Reza; Karimi, Elham; Abbaspour, Majid; Nassiri, Parvin; Taghavi, Lobat
2015-01-01
Spatial assessment of traffic noise pollution intensity will provide urban planners with approximate estimation of citizens exposure to impermissible sound levels. They could identify critical noise pollution areas wherein noise barriers should be embedded. The present study aims at using the Geographic Information System (GIS) to assess spatial changes in traffic noise pollution in Tehran, the capital of Iran, and the largest city in the Middle East. For this purpose, while measuring equivalent sound levels at different time periods of a day and different days of a week in District 14 of Tehran, wherein there are highways and busy streets, the geographic coordination of the measurement points was recorded at the stations. The obtained results indicated that the equivalent sound level did not show a statistically significant difference between weekdays, and morning, afternoon and evening hours as well as time intervals of 10 min, 15 min and 30 min. Then, 91 stations were selected in the target area and equivalent sound level was measured for each station on 3 occasions of the morning (7:00-9:00 a.m.), afternoon (12.00-3:00 p.m.) and evening (5:00-8:00 p.m.) on Saturdays to Wednesdays. As the results suggest, the maximum equivalent sound level (Leq) was reported from Basij Highway, which is a very important connecting thoroughfare in the district, and was equal to 84.2 dB(A), while the minimum equivalent sound level (Leq), measured in the Fajr Hospital, was equal to 59.9 dB(A). The average equivalent sound level was higher than the national standard limit at all stations. The use of sound walls in Highways Basij and Mahallati as well as widening the Streets 17th Shahrivar, Pirouzi and Khavaran, benchmarked on a map, were recommended as the most effective mitigation measures. Additionally, the research findings confirm the outstanding applicability of the Geographic Information System in handling noise pollution data towards depicting noise pollution intensity caused by traffic. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Johnson, Earl E
2017-11-01
To determine safe output sound pressure levels (SPL) for sound amplification devices to preserve hearing sensitivity after usage. A mathematical model consisting of the Modified Power Law (MPL) (Humes & Jesteadt, 1991 ) combined with equations for predicting temporary threshold shift (TTS) and subsequent permanent threshold shift (PTS) (Macrae, 1994b ) was used to determine safe output SPL. The study involves no new human subject measurements of loudness tolerance or threshold shifts. PTS was determined by the MPL model for 234 audiograms and the SPL output recommended by four different validated prescription recommendations for hearing aids. PTS can, on rare occasion, occur as a result of SPL delivered by hearing aids at modern day prescription recommendations. The trading relationship of safe output SPL, decibel hearing level (dB HL) threshold, and PTS was captured with algebraic expressions. Better hearing thresholds lowered the safe output SPL and higher thresholds raised the safe output SPL. Safe output SPL can consider the magnitude of unaided hearing loss. For devices not set to prescriptive levels, limiting the output SPL below the safe levels identified should protect against threshold worsening as a result of long-term usage.
Christensen, Christian Bech; Christensen-Dalsgaard, Jakob; Brandt, Christian; Madsen, Peter Teglberg
2012-01-15
Snakes lack both an outer ear and a tympanic middle ear, which in most tetrapods provide impedance matching between the air and inner ear fluids and hence improve pressure hearing in air. Snakes would therefore be expected to have very poor pressure hearing and generally be insensitive to airborne sound, whereas the connection of the middle ear bone to the jaw bones in snakes should confer acute sensitivity to substrate vibrations. Some studies have nevertheless claimed that snakes are quite sensitive to both vibration and sound pressure. Here we test the two hypotheses that: (1) snakes are sensitive to sound pressure and (2) snakes are sensitive to vibrations, but cannot hear the sound pressure per se. Vibration and sound-pressure sensitivities were quantified by measuring brainstem evoked potentials in 11 royal pythons, Python regius. Vibrograms and audiograms showed greatest sensitivity at low frequencies of 80-160 Hz, with sensitivities of -54 dB re. 1 m s(-2) and 78 dB re. 20 μPa, respectively. To investigate whether pythons detect sound pressure or sound-induced head vibrations, we measured the sound-induced head vibrations in three dimensions when snakes were exposed to sound pressure at threshold levels. In general, head vibrations induced by threshold-level sound pressure were equal to or greater than those induced by threshold-level vibrations, and therefore sound-pressure sensitivity can be explained by sound-induced head vibration. From this we conclude that pythons, and possibly all snakes, lost effective pressure hearing with the complete reduction of a functional outer and middle ear, but have an acute vibration sensitivity that may be used for communication and detection of predators and prey.
NASA Astrophysics Data System (ADS)
Bi, Chuan-Xing; Geng, Lin; Zhang, Xiao-Zheng
2016-05-01
In the sound field with multiple non-stationary sources, the measured pressure is the sum of the pressures generated by all sources, and thus cannot be used directly for studying the vibration and sound radiation characteristics of every source alone. This paper proposes a separation model based on the interpolated time-domain equivalent source method (ITDESM) to separate the pressure field belonging to every source from the non-stationary multi-source sound field. In the proposed method, ITDESM is first extended to establish the relationship between the mixed time-dependent pressure and all the equivalent sources distributed on every source with known location and geometry information, and all the equivalent source strengths at each time step are solved by an iterative solving process; then, the corresponding equivalent source strengths of one interested source are used to calculate the pressure field generated by that source alone. Numerical simulation of two baffled circular pistons demonstrates that the proposed method can be effective in separating the non-stationary pressure generated by every source alone in both time and space domains. An experiment with two speakers in a semi-anechoic chamber further evidences the effectiveness of the proposed method.
Characterization of low-frequency acoustic wave propagation through a periodic corrugated waveguide
NASA Astrophysics Data System (ADS)
Jiang, Changyong; Huang, Lixi
2018-03-01
In this paper, a periodic corrugated waveguide structure is proposed, and its unit-cell is analyzed by the wave finite element method. In low-frequency range, the unit-cell is treated as an equivalent fluid through a homogenization process, and the equivalent acoustic parameters are obtained, which are validated by finite structure simulations and experiments. The proposed structure is shown to add tortuosity to the waveguide, hence higher equivalent fluid density is achieved, while the system elastic modulus remains unchanged. As a result, the equivalent speed of sound is smaller than normal air. The application of such change of speed of sound is demonstrated in the classic quarter-wavelength resonator based on the corrugated waveguide, which gives a lower resonance frequency with the same side branch length. When the waveguide is filled with porous materials, the added tortuosity enhances the broadband, low-frequency sound absorption by increasing the equivalent mass without bringing in excess damping, the latter being partly responsible for the poor performance of usual porous materials in the low-frequency region. Therefore, the proposed structure provides another dimension for the design and optimization of porous sound absorption materials.
Liu, Chang; Jin, Su-Hyun
2015-11-01
This study investigated whether native listeners processed speech differently from non-native listeners in a speech detection task. Detection thresholds of Mandarin Chinese and Korean vowels and non-speech sounds in noise, frequency selectivity, and the nativeness of Mandarin Chinese and Korean vowels were measured for Mandarin Chinese- and Korean-native listeners. The two groups of listeners exhibited similar non-speech sound detection and frequency selectivity; however, the Korean listeners had better detection thresholds of Korean vowels than Chinese listeners, while the Chinese listeners performed no better at Chinese vowel detection than the Korean listeners. Moreover, thresholds predicted from an auditory model highly correlated with behavioral thresholds of the two groups of listeners, suggesting that detection of speech sounds not only depended on listeners' frequency selectivity, but also might be affected by their native language experience. Listeners evaluated their native vowels with higher nativeness scores than non-native listeners. Native listeners may have advantages over non-native listeners when processing speech sounds in noise, even without the required phonetic processing; however, such native speech advantages might be offset by Chinese listeners' lower sensitivity to vowel sounds, a characteristic possibly resulting from their sparse vowel system and their greater cognitive and attentional demands for vowel processing.
Piniak, Wendy E. D.; Mann, David A.; Harms, Craig A.; Jones, T. Todd; Eckert, Scott A.
2016-01-01
Sea turtles spend much of their life in aquatic environments, but critical portions of their life cycle, such as nesting and hatching, occur in terrestrial environments, suggesting that it may be important for them to detect sounds in both air and water. In this study we compared underwater and aerial hearing sensitivities in five juvenile green sea turtles (Chelonia mydas) by measuring auditory evoked potential responses to tone pip stimuli. Green sea turtles detected acoustic stimuli in both media, responding to underwater stimuli between 50 and 1600 Hz and aerial stimuli between 50 and 800 Hz, with maximum sensitivity between 200 and 400 Hz underwater and 300 and 400 Hz in air. When underwater and aerial hearing sensitivities were compared in terms of pressure, green sea turtle aerial sound pressure thresholds were lower than underwater thresholds, however they detected a wider range of frequencies underwater. When thresholds were compared in terms of sound intensity, green sea turtle sound intensity level thresholds were 2–39 dB lower underwater particularly at frequencies below 400 Hz. Acoustic stimuli may provide important environmental cues for sea turtles. Further research is needed to determine how sea turtles behaviorally and physiologically respond to sounds in their environment. PMID:27741231
Piniak, Wendy E D; Mann, David A; Harms, Craig A; Jones, T Todd; Eckert, Scott A
2016-01-01
Sea turtles spend much of their life in aquatic environments, but critical portions of their life cycle, such as nesting and hatching, occur in terrestrial environments, suggesting that it may be important for them to detect sounds in both air and water. In this study we compared underwater and aerial hearing sensitivities in five juvenile green sea turtles (Chelonia mydas) by measuring auditory evoked potential responses to tone pip stimuli. Green sea turtles detected acoustic stimuli in both media, responding to underwater stimuli between 50 and 1600 Hz and aerial stimuli between 50 and 800 Hz, with maximum sensitivity between 200 and 400 Hz underwater and 300 and 400 Hz in air. When underwater and aerial hearing sensitivities were compared in terms of pressure, green sea turtle aerial sound pressure thresholds were lower than underwater thresholds, however they detected a wider range of frequencies underwater. When thresholds were compared in terms of sound intensity, green sea turtle sound intensity level thresholds were 2-39 dB lower underwater particularly at frequencies below 400 Hz. Acoustic stimuli may provide important environmental cues for sea turtles. Further research is needed to determine how sea turtles behaviorally and physiologically respond to sounds in their environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Efroymson, Rebecca Ann; Hargrove, William Walter; Suter, Glenn
A multi-stressor risk assessment was conducted at Yuma Proving Ground, Arizona, as a demonstration of the Military Ecological Risk Assessment Framework. The focus of the assessment was a testing program at Cibola Range, which involved an Apache Longbow helicopter firing Hellfire missiles at moving targets, M60-A1 tanks. This paper focuses on the wildlife risk assessment for the helicopter overflight. The primary stressors were sound and the view of the aircraft. Exposure to desert mule deer (Odocoileus hemionus crooki) was quantified using Air Force sound contour programs NOISEMAP and MR_NMAP, which gave very different results. Slant distance from helicopters to deermore » was also used as a measure of exposure that integrated risk from sound and view of the aircraft. Exposure-response models for the characterization of effects consisted of behavioral thresholds in sound exposure level or maximum sound level units or slant distance. Available sound thresholds were limited for desert mule deer, but a distribution of slant-distance thresholds was available for ungulates. The risk characterization used a weight-of-evidence approach and concluded that risk to mule deer behavior from the Apache overflight is uncertain, but that no risk to mule deer abundance and reproduction is expected.« less
Differential pathologies resulting from sound exposure: Tinnitus vs hearing loss
NASA Astrophysics Data System (ADS)
Longenecker, Ryan James
The first step in identifying the mechanism(s) responsible for tinnitus development would be to discover a neural correlate that is differentially expressed in tinnitus-positive compared to tinnitus negative animals. Previous research has identified several neural correlates of tinnitus in animals that have tested positive for tinnitus. However it is unknown whether all or some of these correlates are linked to tinnitus or if they are a byproduct of hearing loss, a common outcome of tinnitus induction. Abnormally high spontaneous activity has frequently been linked to tinnitus. However, while some studies demonstrate that hyperactivity positively correlates with behavioral evidence of tinnitus, others show that when all animals develop hyperactivity to sound exposure, not all exposed animals show evidence of tinnitus. My working hypothesis is that certain aspects of hyperactivity are linked to tinnitus while other aspects are linked to hearing loss. The first specific aim utilized the gap induced prepulse inhibition of the acoustic startle reflex (GIPAS) to monitor the development of tinnitus in CBA/CaJ mice during one year following sound exposure. Immediately after sound exposure, GIPAS testing revealed widespread gap detection deficits across all frequencies, which was likely due to temporary threshold shifts. However, three months after sound exposure these deficits were limited to a narrow frequency band and were consistently detected up to one year after exposure. This suggests the development of chronic tinnitus is a long lasting and highly dynamic process. The second specific aim assessed hearing loss in sound exposed mice using several techniques. Acoustic brainstem responses recorded initially after sound exposure reveal large magnitude deficits in all exposed mice. However, at the three month period, thresholds return to control levels in all mice suggesting that ABRs are not a reliable tool for assessing permanent hearing loss. Input/output functions of the acoustic startle reflex show that after sound exposure the magnitude of startle responses decrease in most mice, to varying degrees. Lastly, PPI audiometry was able to detect specific behavioral threshold deficits for each mouse after sound exposure. These deficits persist past initial threshold shifts and are able to detect frequency specific permanent threshold shifts. The third specific aim examined hyperactivity and increased bursting activity in the inferior colliculus after sound exposure in relation to tinnitus and hearing loss. Spontaneous firing rates were increased in all mice after sound exposure regardless of behavioral evidence of tinnitus. However, abnormal increased bursting activity was not found in the animals identified with tinnitus but was exhibited in a mouse with broad-band severe threshold deficits. CBA/CaJ mice are a good model for both tinnitus development and noise-induced hearing loss studies. Hyperactivity which was evident in all exposed animals does not seem to be well correlated with behavioral evidence of tinnitus but more likely to be a general result of acoustic over exposure. Data from one animal strongly suggest that wide-spread severe threshold deficits are linked to an elevation of bursting activity predominantly ipsilateral to the side of sound exposure. This result is intriguing and should be followed up in further studies. Data obtained in this study provide new insights into underlying neural pathologies following sound exposure and have possible clinical applications for development of effective treatments and diagnostic tools for tinnitus and hearing loss.
Behavioural Response Thresholds in New Zealand Crab Megalopae to Ambient Underwater Sound
Stanley, Jenni A.; Radford, Craig A.; Jeffs, Andrew G.
2011-01-01
A small number of studies have demonstrated that settlement stage decapod crustaceans are able to detect and exhibit swimming, settlement and metamorphosis responses to ambient underwater sound emanating from coastal reefs. However, the intensity of the acoustic cue required to initiate the settlement and metamorphosis response, and therefore the potential range over which this acoustic cue may operate, is not known. The current study determined the behavioural response thresholds of four species of New Zealand brachyuran crab megalopae by exposing them to different intensity levels of broadcast reef sound recorded from their preferred settlement habitat and from an unfavourable settlement habitat. Megalopae of the rocky-reef crab, Leptograpsus variegatus, exhibited the lowest behavioural response threshold (highest sensitivity), with a significant reduction in time to metamorphosis (TTM) when exposed to underwater reef sound with an intensity of 90 dB re 1 µPa and greater (100, 126 and 135 dB re 1 µPa). Megalopae of the mud crab, Austrohelice crassa, which settle in soft sediment habitats, exhibited no response to any of the underwater reef sound levels. All reef associated species exposed to sound levels from an unfavourable settlement habitat showed no significant change in TTM, even at intensities that were similar to their preferred reef sound for which reductions in TTM were observed. These results indicated that megalopae were able to discern and respond selectively to habitat-specific acoustic cues. The settlement and metamorphosis behavioural response thresholds to levels of underwater reef sound determined in the current study of four species of crabs, enables preliminary estimation of the spatial range at which an acoustic settlement cue may be operating, from 5 m to 40 km depending on the species. Overall, these results indicate that underwater sound is likely to play a major role in influencing the spatial patterns of settlement of coastal crab species. PMID:22163314
van Vugt, Floris T.; Tillmann, Barbara
2014-01-01
The human brain is able to predict the sensory effects of its actions. But how precise are these predictions? The present research proposes a tool to measure thresholds between a simple action (keystroke) and a resulting sound. On each trial, participants were required to press a key. Upon each keystroke, a woodblock sound was presented. In some trials, the sound came immediately with the downward keystroke; at other times, it was delayed by a varying amount of time. Participants were asked to verbally report whether the sound came immediately or was delayed. Participants' delay detection thresholds (in msec) were measured with a staircase-like procedure. We hypothesised that musicians would have a lower threshold than non-musicians. Comparing pianists and brass players, we furthermore hypothesised that, as a result of a sharper attack of the timbre of their instrument, pianists might have lower thresholds than brass players. Our results show that non-musicians exhibited higher thresholds for delay detection (180±104 ms) than the two groups of musicians (102±65 ms), but there were no differences between pianists and brass players. The variance in delay detection thresholds could be explained by variance in sensorimotor synchronisation capacities as well as variance in a purely auditory temporal irregularity detection measure. This suggests that the brain's capacity to generate temporal predictions of sensory consequences can be decomposed into general temporal prediction capacities together with auditory-motor coupling. These findings indicate that the brain has a relatively large window of integration within which an action and its resulting effect are judged as simultaneous. Furthermore, musical expertise may narrow this window down, potentially due to a more refined temporal prediction. This novel paradigm provides a simple test to estimate the temporal precision of auditory-motor action-effect coupling, and the paradigm can readily be incorporated in studies investigating both healthy and patient populations. PMID:24498299
Modal sound transmission loss of a single leaf panel: Asymptotic solutions.
Wang, Chong
2015-12-01
In a previously published paper [C. Wang, J. Acoust. Soc. Am. 137(6), 3514-3522 (2015)], the modal sound transmission coefficients of a single leaf panel were discussed with regard to the inter-modal coupling effects. By incorporating such effect into the equivalent modal radiation impedance, which is directly related to the modal sound transmission coefficient of each mode, the overall sound transmission loss for both normal and randomized sound incidences was computed through a simple modal superposition. Benefiting from the analytical expressions of the equivalent modal impedance and modal transmission coefficients, in this paper, behaviors of modal sound transmission coefficients in several typical frequency ranges are discussed in detail. Asymptotic solutions are also given for the panels with relatively low bending stiffnesses, for which the sound transmission loss has been assumed to follow the mass law of a limp panel. Results are also compared to numerical analysis and the renowned mass law theories.
Variability of road traffic noise recorded by stationary monitoring stations
NASA Astrophysics Data System (ADS)
Bąkowski, Andrzej; Radziszewski, Leszek
2017-11-01
The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads out of the town in the direction of Kraków and Warszawa. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The coefficient of variation and positional variation were proposed for performing comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes. The differences concerned the values of coefficients of variation of the equivalent sound levels.
Towards a unifying basis of auditory thresholds: binaural summation.
Heil, Peter
2014-04-01
Absolute auditory threshold decreases with increasing sound duration, a phenomenon explainable by the assumptions that the sound evokes neural events whose probabilities of occurrence are proportional to the sound's amplitude raised to an exponent of about 3 and that a constant number of events are required for threshold (Heil and Neubauer, Proc Natl Acad Sci USA 100:6151-6156, 2003). Based on this probabilistic model and on the assumption of perfect binaural summation, an equation is derived here that provides an explicit expression of the binaural threshold as a function of the two monaural thresholds, irrespective of whether they are equal or unequal, and of the exponent in the model. For exponents >0, the predicted binaural advantage is largest when the two monaural thresholds are equal and decreases towards zero as the monaural threshold difference increases. This equation is tested and the exponent derived by comparing binaural thresholds with those predicted on the basis of the two monaural thresholds for different values of the exponent. The thresholds, measured in a large sample of human subjects with equal and unequal monaural thresholds and for stimuli with different temporal envelopes, are compatible only with an exponent close to 3. An exponent of 3 predicts a binaural advantage of 2 dB when the two ears are equally sensitive. Thus, listening with two (equally sensitive) ears rather than one has the same effect on absolute threshold as doubling duration. The data suggest that perfect binaural summation occurs at threshold and that peripheral neural signals are governed by an exponent close to 3. They might also shed new light on mechanisms underlying binaural summation of loudness.
Code of Federal Regulations, 2011 CFR
2011-10-01
... second or less. Decibel (dB) means a unit of measurement of sound pressure levels. dB(A) means the sound... operate similar equipment under similar conditions. Sound level or Sound pressure level means ten times... an eight-hour time-weighted-average sound level (TWA) of 85 dB(A), or, equivalently, a dose of 50...
Kastelein, Ronald A; van der Heul, Sander; Verboom, Willem C; Triesscheijn, Rob J V; Jennings, Nancy V
2006-02-01
To prevent grounding of ships and collisions between ships in shallow coastal waters, an underwater data collection and communication network (ACME) using underwater sounds to encode and transmit data is currently under development. Marine mammals might be affected by ACME sounds since they may use sound of a similar frequency (around 12 kHz) for communication, orientation, and prey location. If marine mammals tend to avoid the vicinity of the acoustic transmitters, they may be kept away from ecologically important areas by ACME sounds. One marine mammal species that may be affected in the North Sea is the harbour seal (Phoca vitulina). No information is available on the effects of ACME-like sounds on harbour seals, so this study was carried out as part of an environmental impact assessment program. Nine captive harbour seals were subjected to four sound types, three of which may be used in the underwater acoustic data communication network. The effect of each sound was judged by comparing the animals' location in a pool during test periods to that during baseline periods, during which no sound was produced. Each of the four sounds could be made into a deterrent by increasing its amplitude. The seals reacted by swimming away from the sound source. The sound pressure level (SPL) at the acoustic discomfort threshold was established for each of the four sounds. The acoustic discomfort threshold is defined as the boundary between the areas that the animals generally occupied during the transmission of the sounds and the areas that they generally did not enter during transmission. The SPLs at the acoustic discomfort thresholds were similar for each of the sounds (107 dB re 1 microPa). Based on this discomfort threshold SPL, discomfort zones at sea for several source levels (130-180 dB re 1 microPa) of the sounds were calculated, using a guideline sound propagation model for shallow water. The discomfort zone is defined as the area around a sound source that harbour seals are expected to avoid. The definition of the discomfort zone is based on behavioural discomfort, and does not necessarily coincide with the physical discomfort zone. Based on these results, source levels can be selected that have an acceptable effect on harbour seals in particular areas. The discomfort zone of a communication sound depends on the sound, the source level, and the propagation characteristics of the area in which the sound system is operational. The source level of the communication system should be adapted to each area (taking into account the width of a sea arm, the local sound propagation, and the importance of an area to the affected species). The discomfort zone should not coincide with ecologically important areas (for instance resting, breeding, suckling, and feeding areas), or routes between these areas.
Tzaneva, L
1996-09-01
The discomfort threshold problem is not yet clear from the audiological point of view. Its significance for work physiology and hygiene is not enough clarified. This paper discussed the results of a study of the discomfort threshold, performed including 385 operators from the State Company "Kremikovtzi", divided into 4 groups (3 groups according to length of service and one control group). The most prominent changes were found in operators with increased tonal auditory threshold up to 45 and over 50 dB with high confidential probability. The observed changes are distributed in 3 groups: 1. increased tonal auditory threshold (up to 30 dB) without decrease of the discomfort threshold; 2. decreased discomfort threshold (with about 15-20 dB) at increased tonal auditory threshold (up to 45 dB); 3. decreased discomfort threshold at increased (over 50 dB) tonal auditory threshold. The auditory scope of the operators, belonging to groups III and IV (with the longest length of service) is narrowed, being distorted for the latter. This pathophysiological phenomenon can be explained by an enhanced effect of sound irritation and the presence of a recruitment phenomenon with possible engagement of the central part of the auditory analyzer. It is concluded that the discomfort threshold is a sensitive indicator for the state of the individual norms for speech-sound-noise discomfort. The comparison of the discomfort threshold with the hygienic standards and the noise levels at each particular working place can be used as a criterion for the professional selection for work in conditions of masking noise effect and its tolerance with respect to achieving the individual discomfort level depending on the intensity of the speech-sound-noise signals at a particular working place.
Water quality and bed sediment quality in the Albemarle Sound, North Carolina, 2012–14
Moorman, Michelle C.; Fitzgerald, Sharon A.; Gurley, Laura N.; Rhoni-Aref, Ahmed; Loftin, Keith A.
2017-01-23
The Albemarle Sound region was selected in 2012 as one of two demonstration sites in the Nation to test and improve the design of the National Water Quality Monitoring Council’s National Monitoring Network (NMN) for U.S. Coastal Waters and Tributaries. The goal of the NMN for U.S. Coastal Waters and Tributaries is to provide information about the health of our oceans, coastal ecosystems, and inland influences on coastal waters for improved resource management. The NMN is an integrated, multidisciplinary, and multi-organizational program using multiple sources of data and information to augment current monitoring programs.This report presents and summarizes selected water-quality and bed sediment-quality data collected as part of the demonstration project conducted in two phases. The first phase was an occurrence and distribution study to assess nutrients, metals, pesticides, cyanotoxins, and phytoplankton communities in the Albemarle Sound during the summer of 2012 at 34 sites in Albemarle Sound, nearby sounds, and various tributaries. The second phase consisted of monthly sampling over a year (March 2013 through February 2014) to assess seasonality in a more limited set of constituents including nutrients, cyanotoxins, and phytoplankton communities at a subset (eight) of the sites sampled in the first phase. During the summer of 2012, few constituent concentrations exceeded published water-quality thresholds; however, elevated levels of chlorophyll a and pH were observed in the northern embayments and in Currituck Sound. Chlorophyll a, and metals (copper, iron, and zinc) were detected above a water-quality threshold. The World Health Organization provisional guideline based on cyanobacterial density for high recreational risk was exceeded in approximately 50 percent of water samples collected during the summer of 2012. Cyanobacteria capable of producing toxins were present, but only low levels of cyanotoxins below human health benchmarks were detected. Finally, 12 metals in surficial bed sediments were detected at levels above a published sediment-quality threshold. These metals included chromium, mercury, copper, lead, arsenic, nickel, and cadmium. Sites with several metal concentrations above the respective thresholds had relatively high concentrations of organic carbon or fine sediment (silt plus clay), or both and were predominantly located in the western and northwestern parts of the Albemarle Sound.Results from the second phase were generally similar to those of the first in that relatively few constituents exceeded a water-quality threshold, both pH and chlorophyll a were detected above the respective water-quality thresholds, and many of these elevated concentrations occurred in the northern embayments and in Currituck Sound. In contrast to the results from phase one, the cyanotoxin, microcystin was detected at more than 10 times the water-quality threshold during a phytoplankton bloom on the Chowan River at Mount Gould, North Carolina in August of 2013. This was the only cyanotoxin concentration measured during the entire study that exceeded a respective water-quality threshold.The information presented in this report can be used to improve understanding of water-quality conditions in the Albemarle Sound, particularly when evaluating causal and response variables that are indicators of eutrophication. In particular, this information can be used by State agencies to help develop water-quality criteria for nutrients, and to understand factors like cyanotoxins that may affect fisheries and recreation in the Albemarle Sound region.
Research and Implementation of Heart Sound Denoising
NASA Astrophysics Data System (ADS)
Liu, Feng; Wang, Yutai; Wang, Yanxiang
Heart sound is one of the most important signals. However, the process of getting heart sound signal can be interfered with many factors outside. Heart sound is weak electric signal and even weak external noise may lead to the misjudgment of pathological and physiological information in this signal, thus causing the misjudgment of disease diagnosis. As a result, it is a key to remove the noise which is mixed with heart sound. In this paper, a more systematic research and analysis which is involved in heart sound denoising based on matlab has been made. The study of heart sound denoising based on matlab firstly use the powerful image processing function of matlab to transform heart sound signals with noise into the wavelet domain through wavelet transform and decomposition these signals in muli-level. Then for the detail coefficient, soft thresholding is made using wavelet transform thresholding to eliminate noise, so that a signal denoising is significantly improved. The reconstructed signals are gained with stepwise coefficient reconstruction for the processed detail coefficient. Lastly, 50HZ power frequency and 35 Hz mechanical and electrical interference signals are eliminated using a notch filter.
Speech-sound duration processing in a second language is specific to phonetic categories.
Nenonen, Sari; Shestakova, Anna; Huotilainen, Minna; Näätänen, Risto
2005-01-01
The mismatch negativity (MMN) component of the auditory event-related potential was used to determine the effect of native language, Russian, on the processing of speech-sound duration in a second language, Finnish, that uses duration as a cue for phonological distinction. The native-language effect was compared with Finnish vowels that either can or cannot be categorized using the Russian phonological system. The results showed that the duration-change MMN for the Finnish sounds that could be categorized through Russian was reduced in comparison with that for the Finnish sounds having no Russian equivalent. In the Finnish sounds that can be mapped through the Russian phonological system, the facilitation of the duration processing may be inhibited by the native Russian language. However, for the sounds that have no Russian equivalent, new vowel categories independent of the native Russian language have apparently been established, enabling a native-like duration processing of Finnish.
A review of the perceptual effects of hearing loss for frequencies above 3 kHz.
Moore, Brian C J
2016-12-01
Hearing loss caused by exposure to intense sounds usually has its greatest effects on audiometric thresholds at 4 and 6 kHz. However, in several countries compensation for occupational noise-induced hearing loss is calculated using the average of audiometric thresholds for selected frequencies up to 3 kHz, based on the implicit assumption that hearing loss for frequencies above 3 kHz has no material adverse consequences. This paper assesses whether this assumption is correct. Studies are reviewed that evaluate the role of hearing for frequencies above 3 kHz. Several studies show that frequencies above 3 kHz are important for the perception of speech, especially when background sounds are present. Hearing at high frequencies is also important for sound localization, especially for resolving front-back confusions. Hearing for frequencies above 3 kHz is important for the ability to understand speech in background sounds and for the ability to localize sounds. The audiometric threshold at 4 kHz and perhaps 6 kHz should be taken into account when assessing hearing in a medico-legal context.
Neurometric amplitude-modulation detection threshold in the guinea-pig ventral cochlear nucleus
Sayles, Mark; Füllgrabe, Christian; Winter, Ian M
2013-01-01
Amplitude modulation (AM) is a pervasive feature of natural sounds. Neural detection and processing of modulation cues is behaviourally important across species. Although most ecologically relevant sounds are not fully modulated, physiological studies have usually concentrated on fully modulated (100% modulation depth) signals. Psychoacoustic experiments mainly operate at low modulation depths, around detection threshold (∼5% AM). We presented sinusoidal amplitude-modulated tones, systematically varying modulation depth between zero and 100%, at a range of modulation frequencies, to anaesthetised guinea-pigs while recording spikes from neurons in the ventral cochlear nucleus (VCN). The cochlear nucleus is the site of the first synapse in the central auditory system. At this locus significant signal processing occurs with respect to representation of AM signals. Spike trains were analysed in terms of the vector strength of spike synchrony to the amplitude envelope. Neurons showed either low-pass or band-pass temporal modulation transfer functions, with the proportion of band-pass responses increasing with increasing sound level. The proportion of units showing a band-pass response varies with unit type: sustained chopper (CS) > transient chopper (CT) > primary-like (PL). Spike synchrony increased with increasing modulation depth. At the lowest modulation depth (6%), significant spike synchrony was only observed near to the unit's best modulation frequency for all unit types tested. Modulation tuning therefore became sharper with decreasing modulation depth. AM detection threshold was calculated for each individual unit as a function of modulation frequency. Chopper units have significantly better AM detection thresholds than do primary-like units. AM detection threshold is significantly worse at 40 dB vs. 10 dB above pure-tone spike rate threshold. Mean modulation detection thresholds for sounds 10 dB above pure-tone spike rate threshold at best modulation frequency are (95% CI) 11.6% (10.0–13.1) for PL units, 9.8% (8.2–11.5) for CT units, and 10.8% (8.4–13.2) for CS units. The most sensitive guinea-pig VCN single unit AM detection thresholds are similar to human psychophysical performance (∼3% AM), while the mean neurometric thresholds approach whole animal behavioural performance (∼10% AM). PMID:23629508
Atomic physics effects on tokamak edge drift-tearing modes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hahm, T.S.
1993-03-01
The effects of ionization and charge exchange on the linear stability of drift-tearing modes are analytically investigated. In particular, the linear instability threshold {Delta}{sup Th}, produced by ion sound wave coupling is modified. In the strongly collisional regime, the ionization breaks up the near cancellation of the perturbed electric field and the pressure gradient along the magnetic field, and increases the threshold. In the semi-collisional regime, both ionization and charge exchange act as drag on the ion parallel velocity, and consequently decrease the threshold by reducing the effectiveness of ion sound wave propagation.
Atomic physics effects on tokamak edge drift-tearing modes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hahm, T.S.
1993-03-01
The effects of ionization and charge exchange on the linear stability of drift-tearing modes are analytically investigated. In particular, the linear instability threshold [Delta][sup Th], produced by ion sound wave coupling is modified. In the strongly collisional regime, the ionization breaks up the near cancellation of the perturbed electric field and the pressure gradient along the magnetic field, and increases the threshold. In the semi-collisional regime, both ionization and charge exchange act as drag on the ion parallel velocity, and consequently decrease the threshold by reducing the effectiveness of ion sound wave propagation.
Human sensorimotor tracking of continuous subliminal deviations from isochrony.
Madison, Guy; Merker, Björn
2004-11-03
We show that people continuously react to time perturbations in the range 3-96 ms in otherwise isochronous sound sequences. Musically trained and untrained participants were asked to synchronize with a sequence of sounds, and these two groups performed almost equally below the threshold for conscious detection of the perturbations. Above this threshold the motor reactions accounted for a larger proportion of the stimulus deviations in musically trained participants.
An avoidance behavior model for migrating whale populations
NASA Astrophysics Data System (ADS)
Buck, John R.; Tyack, Peter L.
2003-04-01
A new model is presented for the avoidance behavior of migrating marine mammals in the presence of a noise stimulus. This model assumes that each whale will adjust its movement pattern near a sound source to maintain its exposure below its own individually specific maximum received sound-pressure level, called its avoidance threshold. The probability distribution function (PDF) of this avoidance threshold across individuals characterizes the migrating population. The avoidance threshold PDF may be estimated by comparing the distribution of migrating whales during playback and control conditions at their closest point of approach to the sound source. The proposed model was applied to the January 1998 experiment which placed a single acoustic source from the U.S. Navy SURTASS-LFA system in the migration corridor of grey whales off the California coast. This analysis found that the median avoidance threshold for this migrating grey whale population was 135 dB, with 90% confidence that the median threshold was within +/-3 dB of this value. This value is less than the 141 dB value for 50% avoidance obtained when the 1984 ``Probability of Avoidance'' model of Malme et al.'s was applied to the same data. [Work supported by ONR.
Clinical Validation of a Sound Processor Upgrade in Direct Acoustic Cochlear Implant Subjects
Kludt, Eugen; D’hondt, Christiane; Lenarz, Thomas; Maier, Hannes
2017-01-01
Objective: The objectives of the investigation were to evaluate the effect of a sound processor upgrade on the speech reception threshold in noise and to collect long-term safety and efficacy data after 2½ to 5 years of device use of direct acoustic cochlear implant (DACI) recipients. Study Design: The study was designed as a mono-centric, prospective clinical trial. Setting: Tertiary referral center. Patients: Fifteen patients implanted with a direct acoustic cochlear implant. Intervention: Upgrade with a newer generation of sound processor. Main Outcome Measures: Speech recognition test in quiet and in noise, pure tone thresholds, subject-reported outcome measures. Results: The speech recognition in quiet and in noise is superior after the sound processor upgrade and stable after long-term use of the direct acoustic cochlear implant. The bone conduction thresholds did not decrease significantly after long-term high level stimulation. Conclusions: The new sound processor for the DACI system provides significant benefits for DACI users for speech recognition in both quiet and noise. Especially the noise program with the use of directional microphones (Zoom) allows DACI patients to have much less difficulty when having conversations in noisy environments. Furthermore, the study confirms that the benefits of the sound processor upgrade are available to the DACI recipients even after several years of experience with a legacy sound processor. Finally, our study demonstrates that the DACI system is a safe and effective long-term therapy. PMID:28406848
Data Assimilation Experiments using Quality Controlled AIRS Version 5 Temperature Soundings
NASA Technical Reports Server (NTRS)
Susskind, Joel
2008-01-01
The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AlRS data. Version 5 contains accurate case-by-case error estimates for most derived products, which are also used for quality control. We have conducted forecast impact experiments assimilating AlRS quality controlled temperature profiles using the NASA GEOS-5 data assimilation system, consisting of the NCEP GSI analysis coupled with the NASA FVGCM. Assimilation of quality controlled temperature profiles resulted in significantly improved forecast skill in both the Northern Hemisphere and Southern Hemisphere Extra-Tropics, compared to that obtained from analyses obtained when all data used operationally by NCEP except for AlRS data is assimilated. Experiments using different Quality Control thresholds for assimilation of AlRS temperature retrievals showed that a medium quality control threshold performed better than a tighter threshold, which provided better overall sounding accuracy; or a looser threshold, which provided better spatial coverage of accepted soundings. We are conducting more experiments to further optimize this balance of spatial coverage and sounding accuracy from the data assimilation perspective. In all cases, temperature soundings were assimilated well below cloud level in partially cloudy cases. The positive impact of assimilating AlRS derived atmospheric temperatures all but vanished when only AIRS stratospheric temperatures were assimilated. Forecast skill resulting from assimilation of AlRS radiances uncontaminated by clouds, instead of AlRS temperature soundings, was only slightly better than that resulting from assimilation of only stratospheric AlRS temperatures. This reduction in forecast skill is most likely the result of significant loss of tropospheric information when only AIRS radiances unaffected by clouds are used in the data assimilation process.
Urban Noise Recorded by Stationary Monitoring Stations
NASA Astrophysics Data System (ADS)
Bąkowski, Andrzej; Radziszewski, Leszek; Dekýš, Vladimir
2017-10-01
The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads in the town in the direction of Łódź and Lublin. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The agreement of the distribution of the variable under analysis with normal distribution was evaluated. It was demonstrated that in most cases (for both roads) there was sufficient evidence to reject the null hypothesis at the significance level of 0.05. It was noted that compared with Łódź Road, in the case of Lublin Road data, more cases were recorded for which the null hypothesis could not be rejected. Uncertainties of the equivalent sound level measurements were compared within the periods under analysis. The standard deviation, coefficient of variation, the positional coefficient of variation, the quartile deviation was proposed for performing a comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes and time intervals. The differences concerned the values of uncertainties and coefficients of variation of the equivalent sound levels.
Frank, T
2001-04-01
The first purpose of this study was to determine high-frequency (8 to 16 kHz) thresholds for standardizing reference equivalent threshold sound pressure levels (RETSPLs) for a Sennheiser HDA 200 earphone. The second and perhaps more important purpose of this study was to determine whether repeated high-frequency thresholds using a Sennheiser HDA 200 earphone had a lower intrasubject threshold variability than the ASHA 1994 significant threshold shift criteria for ototoxicity. High-frequency thresholds (8 to 16 kHz) were obtained for 100 (50 male, 50 female) normally hearing (0.25 to 8 kHz) young adults (mean age of 21.2 yr) in four separate test sessions using a Sennheiser HDA 200 earphone. The mean and median high-frequency thresholds were similar for each test session and increased as frequency increased. At each frequency, the high-frequency thresholds were not significantly (p > 0.05) different for gender, test ear, or test session. The median thresholds at each frequency were similar to the 1998 interim ISO RETSPLs; however, large standard deviations and wide threshold distributions indicated very high intersubject threshold variability, especially at 14 and 16 kHz. Threshold repeatability was determined by finding the threshold differences between each possible test session comparison (N = 6). About 98% of all of the threshold differences were within a clinically acceptable range of +/-10 dB from 8 to 14 kHz. The threshold differences between each subject's second, third, and fourth minus their first test session were also found to determine whether intrasubject threshold variability was less than the ASHA 1994 criteria for determining a significant threshold shift due to ototoxicity. The results indicated a false-positive rate of 0% for a threshold shift > or = 20 dB at any frequency and a false-positive rate of 2% for a threshold shift >10 dB at two consecutive frequencies. This study verified that the output of high-frequency audiometers at 0 dB HL using Sennheiser HDA 200 earphones should equal the 1998 interim ISO RETSPLs from 8 to 16 kHz. Further, because the differences between repeated thresholds were well within +/-10 dB and had an extremely low false-positive rate in reference to the ASHA 1994 criteria for a significant threshold shift due to ototoxicity, a Sennheiser HDA 200 earphone can be used for serial monitoring to determine whether significant high-frequency threshold shifts have occurred for patients receiving potentially ototoxic drug therapy.
Breast imaging with ultrasound tomography: update on a comparative study with MR
NASA Astrophysics Data System (ADS)
Ranger, Bryan; Littrup, Peter; Duric, Neb; Li, Cuiping; Schmidt, Steven; Rama, Olsi; Bey-Knight, Lisa
2011-03-01
The objective of this study is to present imaging parameters and display thresholds of an ultrasound tomography (UST) prototype in order to demonstrate analogous visualization of overall breast anatomy and lesions relative to magnetic resonance (MR). Thirty-six women were imaged with MR and our UST prototype. The UST scan generated sound speed, attenuation, and reflection images and were subjected to variable thresholds then fused together into a single UST image. Qualitative and quantitative comparisons of MR and UST images were utilized to identify anatomical similarities and mass characteristics. Overall, UST demonstrated the ability to visualize and characterize breast tissues in a manner comparable to MR without the use of IV contrast. For optimal visualization, fused images utilized thresholds of 1.46+/-0.1 km/s for sound speed to represent architectural features of the breast including parenchyma. An arithmetic combination of images using the logical .AND. and .OR. operators, along with thresholds of 1.52+/-0.03 km/s for sound speed and 0.16+/-0.04 dB/cm for attenuation, allowed for mass detection and characterization similar to MR.
STIMULUS AND TRANSDUCER EFFECTS ON THRESHOLD
Flamme, Gregory A.; Geda, Kyle; McGregor, Kara; Wyllys, Krista; Deiters, Kristy K.; Murphy, William J.; Stephenson, Mark R.
2015-01-01
Objective This study examined differences in thresholds obtained under Sennheiser HDA200 circumaural earphones using pure tone, equivalent rectangular noise bands, and 1/3 octave noise bands relative to thresholds obtained using Telephonics TDH-39P supra-aural earphones. Design Thresholds were obtained via each transducer and stimulus condition six times within a 10-day period. Study Sample Forty-nine adults were selected from a prior study to represent low, moderate, and high threshold reliability. Results The results suggested that (1) only small adjustments were needed to reach equivalent TDH-39P thresholds, (2) pure-tone thresholds obtained with HDA200 circumaural earphones had reliability equal to or better than those obtained using TDH-39P earphones, (3) the reliability of noise-band thresholds improved with broader stimulus bandwidth and was either equal to or better than pure-tone thresholds, and (4) frequency-specificity declined with stimulus bandwidths greater than one Equivalent Rectangular Band, which could complicate early detection of hearing changes that occur within a narrow frequency range. Conclusions These data suggest that circumaural earphones such as the HDA200 headphones provide better reliability for audiometric testing as compared to the TDH-39P earphones. These data support the use of noise bands, preferably ERB noises, as stimuli for audiometric monitoring. PMID:25549164
[Improving speech comprehension using a new cochlear implant speech processor].
Müller-Deile, J; Kortmann, T; Hoppe, U; Hessel, H; Morsnowski, A
2009-06-01
The aim of this multicenter clinical field study was to assess the benefits of the new Freedom 24 sound processor for cochlear implant (CI) users implanted with the Nucleus 24 cochlear implant system. The study included 48 postlingually profoundly deaf experienced CI users who demonstrated speech comprehension performance with their current speech processor on the Oldenburg sentence test (OLSA) in quiet conditions of at least 80% correct scores and who were able to perform adaptive speech threshold testing using the OLSA in noisy conditions. Following baseline measures of speech comprehension performance with their current speech processor, subjects were upgraded to the Freedom 24 speech processor. After a take-home trial period of at least 2 weeks, subject performance was evaluated by measuring the speech reception threshold with the Freiburg multisyllabic word test and speech intelligibility with the Freiburg monosyllabic word test at 50 dB and 70 dB in the sound field. The results demonstrated highly significant benefits for speech comprehension with the new speech processor. Significant benefits for speech comprehension were also demonstrated with the new speech processor when tested in competing background noise.In contrast, use of the Abbreviated Profile of Hearing Aid Benefit (APHAB) did not prove to be a suitably sensitive assessment tool for comparative subjective self-assessment of hearing benefits with each processor. Use of the preprocessing algorithm known as adaptive dynamic range optimization (ADRO) in the Freedom 24 led to additional improvements over the standard upgrade map for speech comprehension in quiet and showed equivalent performance in noise. Through use of the preprocessing beam-forming algorithm BEAM, subjects demonstrated a highly significant improved signal-to-noise ratio for speech comprehension thresholds (i.e., signal-to-noise ratio for 50% speech comprehension scores) when tested with an adaptive procedure using the Oldenburg sentences in the clinical setting S(0)N(CI), with speech signal at 0 degrees and noise lateral to the CI at 90 degrees . With the convincing findings from our evaluations of this multicenter study cohort, a trial with the Freedom 24 sound processor for all suitable CI users is recommended. For evaluating the benefits of a new processor, the comparative assessment paradigm used in our study design would be considered ideal for use with individual patients.
Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry
Grysiński, Tomasz; Kręcicki, Tomasz
2018-01-01
Background Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headphones, the reference sound level can be calculated once for all devices of the same model. Objective This study aimed to compare the hearing threshold measured by a mobile device that was calibrated using a model-specific, biologically determined reference sound level with the hearing threshold obtained in pure-tone audiometry. Methods Trial participants were recruited offline using face-to-face prompting from among Otolaryngology Clinic patients, who own Android-based mobile devices with bundled headphones. The hearing threshold was obtained on a mobile device by means of an open access app, Hearing Test, with incorporated model-specific reference sound levels. These reference sound levels were previously determined in uncontrolled conditions in relation to the hearing threshold of normal-hearing persons. An audiologist-assisted self-measurement was conducted by the participants in a sound booth, and it involved determining the lowest audible sound generated by the device within the frequency range of 250 Hz to 8 kHz. The results were compared with pure-tone audiometry. Results A total of 70 subjects, 34 men and 36 women, aged 18-71 years (mean 36, standard deviation [SD] 11) participated in the trial. The hearing threshold obtained on mobile devices was significantly different from the one determined by pure-tone audiometry with a mean difference of 2.6 dB (95% CI 2.0-3.1) and SD of 8.3 dB (95% CI 7.9-8.7). The number of differences not greater than 10 dB reached 89% (95% CI 88-91), whereas the mean absolute difference was obtained at 6.5 dB (95% CI 6.2-6.9). Sensitivity and specificity for a mobile-based screening method were calculated at 98% (95% CI 93-100.0) and 79% (95% CI 71-87), respectively. Conclusions The method of hearing self-test carried out on mobile devices with bundled headphones demonstrates high compatibility with pure-tone audiometry, which confirms its potential application in hearing monitoring, screening tests, or epidemiological examinations on a large scale. PMID:29321124
Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry.
Masalski, Marcin; Grysiński, Tomasz; Kręcicki, Tomasz
2018-01-10
Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headphones, the reference sound level can be calculated once for all devices of the same model. This study aimed to compare the hearing threshold measured by a mobile device that was calibrated using a model-specific, biologically determined reference sound level with the hearing threshold obtained in pure-tone audiometry. Trial participants were recruited offline using face-to-face prompting from among Otolaryngology Clinic patients, who own Android-based mobile devices with bundled headphones. The hearing threshold was obtained on a mobile device by means of an open access app, Hearing Test, with incorporated model-specific reference sound levels. These reference sound levels were previously determined in uncontrolled conditions in relation to the hearing threshold of normal-hearing persons. An audiologist-assisted self-measurement was conducted by the participants in a sound booth, and it involved determining the lowest audible sound generated by the device within the frequency range of 250 Hz to 8 kHz. The results were compared with pure-tone audiometry. A total of 70 subjects, 34 men and 36 women, aged 18-71 years (mean 36, standard deviation [SD] 11) participated in the trial. The hearing threshold obtained on mobile devices was significantly different from the one determined by pure-tone audiometry with a mean difference of 2.6 dB (95% CI 2.0-3.1) and SD of 8.3 dB (95% CI 7.9-8.7). The number of differences not greater than 10 dB reached 89% (95% CI 88-91), whereas the mean absolute difference was obtained at 6.5 dB (95% CI 6.2-6.9). Sensitivity and specificity for a mobile-based screening method were calculated at 98% (95% CI 93-100.0) and 79% (95% CI 71-87), respectively. The method of hearing self-test carried out on mobile devices with bundled headphones demonstrates high compatibility with pure-tone audiometry, which confirms its potential application in hearing monitoring, screening tests, or epidemiological examinations on a large scale. ©Marcin Masalski, Tomasz Grysiński, Tomasz Kręcicki. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 10.01.2018.
Hearing at low and infrasonic frequencies.
Møller, H; Pedersen, C S
2004-01-01
The human perception of sound at frequencies below 200 Hz is reviewed. Knowledge about our perception of this frequency range is important, since much of the sound we are exposed to in our everyday environment contains significant energy in this range. Sound at 20-200 Hz is called low-frequency sound, while for sound below 20 Hz the term infrasound is used. The hearing becomes gradually less sensitive for decreasing frequency, but despite the general understanding that infrasound is inaudible, humans can perceive infrasound, if the level is sufficiently high. The ear is the primary organ for sensing infrasound, but at levels somewhat above the hearing threshold it is possible to feel vibrations in various parts of the body. The threshold of hearing is standardized for frequencies down to 20 Hz, but there is a reasonably good agreement between investigations below this frequency. It is not only the sensitivity but also the perceived character of a sound that changes with decreasing frequency. Pure tones become gradually less continuous, the tonal sensation ceases around 20 Hz, and below 10 Hz it is possible to perceive the single cycles of the sound. A sensation of pressure at the eardrums also occurs. The dynamic range of the auditory system decreases with decreasing frequency. This compression can be seen in the equal-loudness-level contours, and it implies that a slight increase in level can change the perceived loudness from barely audible to loud. Combined with the natural spread in thresholds, it may have the effect that a sound, which is inaudible to some people, may be loud to others. Some investigations give evidence of persons with an extraordinary sensitivity in the low and infrasonic frequency range, but further research is needed in order to confirm and explain this phenomenon.
Kastelein, Ronald A; Helder-Hoek, Lean; Van de Voorde, Shirley
2017-10-01
Safety criteria for naval sonar sounds are needed to protect harbor porpoise hearing. Two porpoises were exposed to sequences of AN/SQS-53C sonar playback sounds (3.5-4.1 kHz, without significant harmonics), at a mean received sound pressure level of 142 dB re 1 μPa, with a duty cycle of 96% (almost continuous). Behavioral hearing thresholds at 4 and 5.7 kHz were determined before and after exposure to the fatiguing sound, in order to quantify temporary threshold shifts (TTSs) and hearing recovery. Control sessions were also conducted. Significant mean initial TTS 1-4 of 5.2 dB at 4 kHz and 3.1 dB at 5.7 kHz occurred after 30 min exposures (mean received cumulative sound exposure level, SEL cum : 175 dB re 1 μPa 2 s). Hearing thresholds returned to pre-exposure levels within 12 min. Significant mean initial TTS 1-4 of 5.5 dB at 4 kHz occurred after 60 min exposures (SEL cum : 178 dB re 1 μPa 2 s). Hearing recovered within 60 min. The SEL cum for AN/SQS-53C sonar sounds required to induce 6 dB of TTS 4 min after exposure (the definition of TTS onset) is expected to be between 175 and 180 dB re 1 μPa 2 s.
Diagnostic pure-tone audiometry in schools: mobile testing without a sound-treated environment.
Swanepoel, De Wet; Maclennan-Smith, Felicity; Hall, James W
2013-01-01
To validate diagnostic pure-tone audiometry in schools without a sound-treated environment using an audiometer that incorporates insert earphones covered by circumaural earcups and real-time environmental noise monitoring. A within-subject repeated measures design was employed to compare air (250 to 8000 Hz) and bone (250 to 4000 Hz) conduction pure-tone thresholds measured in natural school environments with thresholds measured in a sound-treated booth. 149 children (54% female) with an average age of 6.9 yr (SD = 0.6; range = 5-8). Average difference between the booth and natural environment thresholds was 0.0 dB (SD = 3.6) for air conduction and 0.1 dB (SD = 3.1) for bone conduction. Average absolute difference between the booth and natural environment was 2.1 dB (SD = 2.9) for air conduction and 1.6 dB (SD = 2.7) for bone conduction. Almost all air- (96%) and bone-conduction (97%) threshold comparisons between the natural and booth test environments were within 0 to 5 dB. No statistically significant differences between thresholds recorded in the natural and booth environments for air- and bone-conduction audiometry were found (p > 0.01). Diagnostic air- and bone-conduction audiometry in schools, without a sound-treated room, is possible with sufficient earphone attenuation and real-time monitoring of environmental noise. Audiological diagnosis on-site for school screening may address concerns of false-positive referrals and poor follow-up compliance and allow for direct referral to audiological and/or medical intervention. American Academy of Audiology.
Tsaneva, L
1993-01-01
The results from the investigation of the threshold of discomfort in 385 operators from firm "Kremikovtsi" are discussed. The most expressed changes are found in operators with increased tonal auditory threshold up to 45 and above 50 dB, in high confidential probability. The observed changes in the threshold of discomfort are classified into 3 groups: 1). Raised tonal auditory threshold (up to 30 dB) without decrease in the threshold of discomfort; 2). Decreased threshold of discomfort (with about 15-20 dB) in raised tonal auditory threshold (up to 45 dB); 3). Decreased threshold of discomfort on the background of raised (above 50 dB) tonal auditory threshold. On 4 figures are represented audiograms, illustrating the state of tonal auditory threshold, the field of hearing and the threshold of discomfort. The field of hearing of the operators from the III and IV groups is narrowed, and in the latter also deformed. The explanation of this pathophysiological phenomenon is related to the increased effect of the sound irritation and the presence of recruitment phenomenon with possible engagement of the central end of the auditory analyser. It is underlined, that the threshold of discomfort is sensitive index for the state of the individual norms of each operator for the speech-sound-noise discomfort.(ABSTRACT TRUNCATED AT 250 WORDS)
Simmons, Andrea Megela; Hom, Kelsey N; Simmons, James A
2017-03-01
Thresholds to short-duration narrowband frequency-modulated (FM) sweeps were measured in six big brown bats (Eptesicus fuscus) in a two-alternative forced choice passive listening task before and after exposure to band-limited noise (lower and upper frequencies between 10 and 50 kHz, 1 h, 116-119 dB sound pressure level root mean square; sound exposure level 152 dB). At recovery time points of 2 and 5 min post-exposure, thresholds varied from -4 to +4 dB from pre-exposure threshold estimates. Thresholds after sham (control) exposures varied from -6 to +2 dB from pre-exposure estimates. The small differences in thresholds after noise and sham exposures support the hypothesis that big brown bats do not experience significant temporary threshold shifts under these experimental conditions. These results confirm earlier findings showing stability of thresholds to broadband FM sweeps at longer recovery times after exposure to broadband noise. Big brown bats may have evolved a lessened susceptibility to noise-induced hearing losses, related to the special demands of echolocation.
Boddy, Lynne M; Noonan, Robert J; Kim, Youngwon; Rowlands, Alex V; Welk, Greg J; Knowles, Zoe R; Fairclough, Stuart J
2018-03-28
To examine the comparability of children's free-living sedentary time (ST) derived from raw acceleration thresholds for wrist mounted GENEActiv accelerometer data, with ST estimated using the waist mounted ActiGraph 100count·min -1 threshold. Secondary data analysis. 108 10-11-year-old children (n=43 boys) from Liverpool, UK wore one ActiGraph GT3X+ and one GENEActiv accelerometer on their right hip and left wrist, respectively for seven days. Signal vector magnitude (SVM; mg) was calculated using the ENMO approach for GENEActiv data. ST was estimated from hip-worn ActiGraph data, applying the widely used 100count·min -1 threshold. ROC analysis using 10-fold hold-out cross-validation was conducted to establish a wrist-worn GENEActiv threshold comparable to the hip ActiGraph 100count·min -1 threshold. GENEActiv data were also classified using three empirical wrist thresholds and equivalence testing was completed. Analysis indicated that a GENEActiv SVM value of 51mg demonstrated fair to moderate agreement (Kappa: 0.32-0.41) with the 100count·min -1 threshold. However, the generated and empirical thresholds for GENEActiv devices were not significantly equivalent to ActiGraph 100count·min -1 . GENEActiv data classified using the 35.6mg threshold intended for ActiGraph devices generated significantly equivalent ST estimates as the ActiGraph 100count·min -1 . The newly generated and empirical GENEActiv wrist thresholds do not provide equivalent estimates of ST to the ActiGraph 100count·min -1 approach. More investigation is required to assess the validity of applying ActiGraph cutpoints to GENEActiv data. Future studies are needed to examine the backward compatibility of ST data and to produce a robust method of classifying SVM-derived ST. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... Guidance for Assessing the Effects of Anthropogenic Sound on Marine Mammals--Acoustic Threshold Levels for.... SUMMARY: The National Marine Fisheries Service (NMFS) on behalf of NMFS and the National Ocean Service... availability of draft guidance for assessing the effects of anthropogenic sound on marine mammal species under...
Comparison of nine methods to estimate ear-canal stimulus levels
Souza, Natalie N.; Dhar, Sumitrajit; Neely, Stephen T.; Siegel, Jonathan H.
2014-01-01
The reliability of nine measures of the stimulus level in the human ear canal was compared by measuring the sensitivity of behavioral hearing thresholds to changes in the depth of insertion of an otoacoustic emission probe. Four measures were the ear-canal pressure, the eardrum pressure estimated from it and the pressure measured in an ear simulator with and without compensation for insertion depth. The remaining five quantities were derived from the ear-canal pressure and the Thévenin-equivalent source characteristics of the probe: Forward pressure, initial forward pressure, the pressure transmitted into the middle ear, eardrum sound pressure estimated by summing the magnitudes of the forward and reverse pressure (integrated pressure) and absorbed power. Two sets of behavioral thresholds were measured in 26 subjects from 0.125 to 20 kHz, with the probe inserted at relatively deep and shallow positions in the ear canal. The greatest dependence on insertion depth was for transmitted pressure and absorbed power. The measures with the least dependence on insertion depth throughout the frequency range (best performance) included the depth-compensated simulator, eardrum, forward, and integrated pressures. Among these, forward pressure is advantageous because it quantifies stimulus phase. PMID:25324079
Sound field reproduction as an equivalent acoustical scattering problem.
Fazi, Filippo Maria; Nelson, Philip A
2013-11-01
Given a continuous distribution of acoustic sources, the determination of the source strength that ensures the synthesis of a desired sound field is shown to be identical to the solution of an equivalent acoustic scattering problem. The paper begins with the presentation of the general theory that underpins sound field reproduction with secondary sources continuously arranged on the boundary of the reproduction region. The process of reproduction by a continuous source distribution is modeled by means of an integral operator (the single layer potential). It is then shown how the solution of the sound reproduction problem corresponds to that of an equivalent scattering problem. Analytical solutions are computed for two specific instances of this problem, involving, respectively, the use of a secondary source distribution in spherical and planar geometries. The results are shown to be the same as those obtained with analyses based on High Order Ambisonics and Wave Field Synthesis, respectively, thus bringing to light a fundamental analogy between these two methods of sound reproduction. Finally, it is shown how the physical optics (Kirchhoff) approximation enables the derivation of a high-frequency simplification for the problem under consideration, this in turn being related to the secondary source selection criterion reported in the literature on Wave Field Synthesis.
Relations among pure-tone sound stimuli, neural activity, and the loudness sensation
NASA Technical Reports Server (NTRS)
Howes, W. L.
1972-01-01
Both the physiological and psychological responses to pure-tone sound stimuli are used to derive formulas which: (1) relate the loudness, loudness level, and sound-pressure level of pure tones; (2) apply continuously over most of the acoustic regime, including the loudness threshold; and (3) contain no undetermined coefficients. Some of the formulas are fundamental for calculating the loudness of any sound. Power-law formulas relating the pure-tone sound stimulus, neural activity, and loudness are derived from published data.
Gordon, Shira D; Ter Hofstede, Hannah M
2018-03-22
Animals co-occur with multiple predators, making sensory systems that can encode information about diverse predators advantageous. Moths in the families Noctuidae and Erebidae have ears with two auditory receptor cells (A1 and A2) used to detect the echolocation calls of predatory bats. Bat communities contain species that vary in echolocation call duration, and the dynamic range of A1 is limited by the duration of sound, suggesting that A1 provides less information about bats with shorter echolocation calls. To test this hypothesis, we obtained intensity-response functions for both receptor cells across many moth species for sound pulse durations representing the range of echolocation call durations produced by bat species in northeastern North America. We found that the threshold and dynamic range of both cells varied with sound pulse duration. The number of A1 action potentials per sound pulse increases linearly with increasing amplitude for long-duration pulses, saturating near the A2 threshold. For short sound pulses, however, A1 saturates with only a few action potentials per pulse at amplitudes far lower than the A2 threshold for both single sound pulses and pulse sequences typical of searching or approaching bats. Neural adaptation was only evident in response to approaching bat sequences at high amplitudes, not search-phase sequences. These results show that, for short echolocation calls, a large range of sound levels cannot be coded by moth auditory receptor activity, resulting in no information about the distance of a bat, although differences in activity between ears might provide information about direction. © 2018. Published by The Company of Biologists Ltd.
Park, Hong Ju; Lee, In-Sik; Shin, Jung Eun; Lee, Yeo Jin; Park, Mun Su
2010-01-01
To better characterize both ocular and cervical vestibular evoked myogenic potentials (VEMP) responses at different frequencies of sound in 20 normal subjects. Cervical and ocular VEMPs were recorded. The intensities of sound stimulation decreased from the maximal intensity, until no responses were evoked. Thresholds, amplitudes, latencies and interaural amplitude difference ratio (IADR) at the maximal stimulation were calculated. Both tests showed the similar frequency tuning, with the lowest threshold and highest amplitude for 500-Hz tone-burst stimuli. Sound stimulation at 500Hz showed the response rates of 100% in both tests. Cervical VEMPs showed higher incidence than ocular VEMPs. Ocular VEMP thresholds were significantly higher than those of cervical VEMP. Cervical VEMP amplitudes were significantly higher than ocular VEMP amplitudes. IADRs of ocular and cervical VEMPs did not differ significantly. Ocular VEMP showed the similar frequency tuning to cervical VEMP. Cervical VEMP responses showed higher incidence, lower thresholds and larger amplitudes than ocular VEMP. Cervical VEMP is a more reliable measure than ocular VEMP, though the results of both tests will be complementary. Five hundred Hertz is the optimal frequency to use. Copyright 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Saliba, Joe; Al-Reefi, Mahmoud; Carriere, Junie S; Verma, Neil; Provencal, Christiane; Rappaport, Jamie M
2017-04-01
Objectives (1) To compare the accuracy of 2 previously validated mobile-based hearing tests in determining pure tone thresholds and screening for hearing loss. (2) To determine the accuracy of mobile audiometry in noisy environments through noise reduction strategies. Study Design Prospective clinical study. Setting Tertiary hospital. Subjects and Methods Thirty-three adults with or without hearing loss were tested (mean age, 49.7 years; women, 42.4%). Air conduction thresholds measured as pure tone average and at individual frequencies were assessed by conventional audiogram and by 2 audiometric applications (consumer and professional) on a tablet device. Mobile audiometry was performed in a quiet sound booth and in a noisy sound booth (50 dB of background noise) through active and passive noise reduction strategies. Results On average, 91.1% (95% confidence interval [95% CI], 89.1%-93.2%) and 95.8% (95% CI, 93.5%-97.1%) of the threshold values obtained in a quiet sound booth with the consumer and professional applications, respectively, were within 10 dB of the corresponding audiogram thresholds, as compared with 86.5% (95% CI, 82.6%-88.5%) and 91.3% (95% CI, 88.5%-92.8%) in a noisy sound booth through noise cancellation. When screening for at least moderate hearing loss (pure tone average >40 dB HL), the consumer application showed a sensitivity and specificity of 87.5% and 95.9%, respectively, and the professional application, 100% and 95.9%. Overall, patients preferred mobile audiometry over conventional audiograms. Conclusion Mobile audiometry can correctly estimate pure tone thresholds and screen for moderate hearing loss. Noise reduction strategies in mobile audiometry provide a portable effective solution for hearing assessments outside clinical settings.
Detection of Sound Rise Time by Adults with Dyslexia
ERIC Educational Resources Information Center
Hamalainen, J.; Leppanen, P.H.T.; Torppa, M.; Muller, K.; Lyytinen, H.
2005-01-01
Low sensitivity to amplitude modulated (AM) sounds is reported to be associated with dyslexia. An important aspect of amplitude modulation cycles are the rise and fall times within the sound. In this study, simplified stimuli equivalent to just one cycle were used and sensitivity to varying rise times was explored. Adult participants with dyslexia…
Discrete Huygens’ modeling for the characterization of a sound absorbing medium
NASA Astrophysics Data System (ADS)
Chai, L.; Kagawa, Y.
2007-07-01
Based on the equivalence between the wave propagation in the electrical transmission-lines and acoustic tubes, the authors proposed the use of the transmission-line matrix modeling (TLM) for time-domain solution method of the sound field. TLM is known in electromagnetic engineering community, which is equivalent to the discrete Huygens' modeling. The wave propagation is simulated by tracing the sequences of the transmission and scattering of impulses. The theory and the demonstrated examples are presented in the references, in which a sound absorbing field was preliminarily considered to be a medium with simple acoustic resistance independent of frequency and the angle of incidence for the absorbing layer placed on the room wall surface. The present work is concerned with the time-domain response for the characterization of the sound absorbing materials. A lossy component with variable propagation velocity is introduced for sound absorbing materials to facilitate the energy consumption. The frequency characteristics of the absorption coefficient are also considered for the normal, oblique and random incidence. Some numerical demonstrations show that the present modeling provide a reasonable modeling of the homogeneous sound absorbing materials in time domain.
Ciaramitaro, Vivian M; Chow, Hiu Mei; Eglington, Luke G
2017-03-01
We used a cross-modal dual task to examine how changing visual-task demands influenced auditory processing, namely auditory thresholds for amplitude- and frequency-modulated sounds. Observers had to attend to two consecutive intervals of sounds and report which interval contained the auditory stimulus that was modulated in amplitude (Experiment 1) or frequency (Experiment 2). During auditory-stimulus presentation, observers simultaneously attended to a rapid sequential visual presentation-two consecutive intervals of streams of visual letters-and had to report which interval contained a particular color (low load, demanding less attentional resources) or, in separate blocks of trials, which interval contained more of a target letter (high load, demanding more attentional resources). We hypothesized that if attention is a shared resource across vision and audition, an easier visual task should free up more attentional resources for auditory processing on an unrelated task, hence improving auditory thresholds. Auditory detection thresholds were lower-that is, auditory sensitivity was improved-for both amplitude- and frequency-modulated sounds when observers engaged in a less demanding (compared to a more demanding) visual task. In accord with previous work, our findings suggest that visual-task demands can influence the processing of auditory information on an unrelated concurrent task, providing support for shared attentional resources. More importantly, our results suggest that attending to information in a different modality, cross-modal attention, can influence basic auditory contrast sensitivity functions, highlighting potential similarities between basic mechanisms for visual and auditory attention.
Automated audiometry using apple iOS-based application technology.
Foulad, Allen; Bui, Peggy; Djalilian, Hamid
2013-11-01
The aim of this study is to determine the feasibility of an Apple iOS-based automated hearing testing application and to compare its accuracy with conventional audiometry. Prospective diagnostic study. Setting Academic medical center. An iOS-based software application was developed to perform automated pure-tone hearing testing on the iPhone, iPod touch, and iPad. To assess for device variations and compatibility, preliminary work was performed to compare the standardized sound output (dB) of various Apple device and headset combinations. Forty-two subjects underwent automated iOS-based hearing testing in a sound booth, automated iOS-based hearing testing in a quiet room, and conventional manual audiometry. The maximum difference in sound intensity between various Apple device and headset combinations was 4 dB. On average, 96% (95% confidence interval [CI], 91%-100%) of the threshold values obtained using the automated test in a sound booth were within 10 dB of the corresponding threshold values obtained using conventional audiometry. When the automated test was performed in a quiet room, 94% (95% CI, 87%-100%) of the threshold values were within 10 dB of the threshold values obtained using conventional audiometry. Under standardized testing conditions, 90% of the subjects preferred iOS-based audiometry as opposed to conventional audiometry. Apple iOS-based devices provide a platform for automated air conduction audiometry without requiring extra equipment and yield hearing test results that approach those of conventional audiometry.
Sound levels, hearing habits and hazards of using portable cassete players
NASA Astrophysics Data System (ADS)
Hellström, P.-A.; Axelsson, A.
1988-12-01
The maximum output sound pressure level ( SPL) from different types of portable cassette players (PCP's) and different headphones was analyzed by using KEMAR in one-third octave bands. The equivalent free-field dB(A) level (EqA-FFSL) was computed from the one-third octave bands corrected by the free-field to the eardrum transfer function. The dB(A) level varied between 104 dB from a low-cost PCP with supra-aural headphones (earphones with headbands and foam pads fitting against the pinna) to 126 dB from a high quality PCP with semi-aural headphones (small earphones without headbands to be used in the concha of the external ear). The cassette tapes used in this study were recorded with music, white noise, narrowband noise and pure tones. The equivalent and maximum SPL was measured in the ear canal (1 mm from eardrum) with the use of mini-microphones in 15 young subjects listening to pop music from PCP's at the highest level they considered comfortable. These SPL measurements corresponded to 112 dB(A) in free field. In a temporary threshold shift ( TTS) study, ten teenagers—four girls and six boys—listened to pop music for 1 h with PCP's at a level they enjoyed. The mean TTS value was 5-10 dB for frequencies between 1 and 8 kHz. In one subject the maximum TTS was 35 dB at 5-6 dB kHz. In order to acquire information about listening habits among youngsters using PCP's, 154 seventh and eighth graders (age 14-15) were interviewed. They used PCP's much less than expected during most of the year, but an increase was reported during the summer holidays.
Threshold flux-controlled memristor model and its equivalent circuit implementation
NASA Astrophysics Data System (ADS)
Wu, Hua-Gan; Bao, Bo-Cheng; Chen, Mo
2014-11-01
Modeling a memristor is an effective way to explore the memristor properties due to the fact that the memristor devices are still not commercially available for common researchers. In this paper, a physical memristive device is assumed to exist whose ionic drift direction is perpendicular to the direction of the applied voltage, upon which, corresponding to the HP charge-controlled memristor model, a novel threshold flux-controlled memristor model with a window function is proposed. The fingerprints of the proposed model are analyzed. Especially, a practical equivalent circuit of the proposed model is realized, from which the corresponding experimental fingerprints are captured. The equivalent circuit of the threshold memristor model is appropriate for various memristors based breadboard experiments.
30 CFR 75.211 - Roof testing and scaling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... examination does not disclose a hazardous condition, sound and vibration roof tests, or other equivalent tests, shall be made where supports are to be installed. When sound and vibration tests are made, they shall be...
30 CFR 75.211 - Roof testing and scaling.
Code of Federal Regulations, 2014 CFR
2014-07-01
... examination does not disclose a hazardous condition, sound and vibration roof tests, or other equivalent tests, shall be made where supports are to be installed. When sound and vibration tests are made, they shall be...
30 CFR 75.211 - Roof testing and scaling.
Code of Federal Regulations, 2012 CFR
2012-07-01
... examination does not disclose a hazardous condition, sound and vibration roof tests, or other equivalent tests, shall be made where supports are to be installed. When sound and vibration tests are made, they shall be...
30 CFR 75.211 - Roof testing and scaling.
Code of Federal Regulations, 2013 CFR
2013-07-01
... examination does not disclose a hazardous condition, sound and vibration roof tests, or other equivalent tests, shall be made where supports are to be installed. When sound and vibration tests are made, they shall be...
Adaptive gain and filtering circuit for a sound reproduction system
NASA Technical Reports Server (NTRS)
Engebretson, A. Maynard (Inventor); O'Connell, Michael P. (Inventor)
1998-01-01
Adaptive compressive gain and level dependent spectral shaping circuitry for a hearing aid include a microphone to produce an input signal and a plurality of channels connected to a common circuit output. Each channel has a preset frequency response. Each channel includes a filter with a preset frequency response to receive the input signal and to produce a filtered signal, a channel amplifier to amplify the filtered signal to produce a channel output signal, a threshold register to establish a channel threshold level, and a gain circuit. The gain circuit increases the gain of the channel amplifier when the channel output signal falls below the channel threshold level and decreases the gain of the channel amplifier when the channel output signal rises above the channel threshold level. A transducer produces sound in response to the signal passed by the common circuit output.
Shinn-Cunningham, Barbara
2017-10-17
This review provides clinicians with an overview of recent findings relevant to understanding why listeners with normal hearing thresholds (NHTs) sometimes suffer from communication difficulties in noisy settings. The results from neuroscience and psychoacoustics are reviewed. In noisy settings, listeners focus their attention by engaging cortical brain networks to suppress unimportant sounds; they then can analyze and understand an important sound, such as speech, amidst competing sounds. Differences in the efficacy of top-down control of attention can affect communication abilities. In addition, subclinical deficits in sensory fidelity can disrupt the ability to perceptually segregate sound sources, interfering with selective attention, even in listeners with NHTs. Studies of variability in control of attention and in sensory coding fidelity may help to isolate and identify some of the causes of communication disorders in individuals presenting at the clinic with "normal hearing." How well an individual with NHTs can understand speech amidst competing sounds depends not only on the sound being audible but also on the integrity of cortical control networks and the fidelity of the representation of suprathreshold sound. Understanding the root cause of difficulties experienced by listeners with NHTs ultimately can lead to new, targeted interventions that address specific deficits affecting communication in noise. http://cred.pubs.asha.org/article.aspx?articleid=2601617.
Avalanches of Singing Sand in the Laboratory
NASA Astrophysics Data System (ADS)
Dagois-Bohy, Simon; Courrech Du Pont, Sylvain; Douady, Stéphane
2011-03-01
The song of dunes is a natural phenomenon that has arisen travellers' curiosity for a long time, from Marco Polo to R.A. Bagnold. Scientific observations in the XXth century have shown that the sound is emitted during a shear flow of these particular grains, the free surface of the flow having coherent vibrations like a loud speaker. The sound emission is also submitted to a threshold effect with many parameters like humidity, flow speed, surface of the grains. The sound has been reproduced in laboratory avalanche experiments close to the natural phenomenon on field, but set in a channel with a hard bottom and a few centimeters of sand flowing, which contradicts explanations of the sound that involve a sand dune under the avalanche flow. Flow rates measurements also show the presence of a plug region in the flow above the sheared band, with the same characteristic length as the coherence zones of the sound. Finally we show experimentally that the Froude number, once modified to take into account the height of this plug band, is the parameter that sets the amplitude of the sound, and produces a threshold that depends on the grain type.
49 CFR 227.115 - Hearing protectors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... employees exposed to sound levels that meet or exceed the action level. (c) Required use at action level. A railroad shall require the use of hearing protectors when an employee is exposed to sound levels that meet... hearing protectors when an employee is exposed to sound levels equivalent to an 8-hour TWA of 90 dB(A) or...
49 CFR 228.101 - Distance requirement; definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... CFR 172.504). (5) The term L eq (8) shall mean the equivalent steady state sound level which in 8 hours would contain the same acoustic energy as the time-varying sound level during the same time period. ...
Zhao, Xiaoyan; Qin, Renjia
2015-04-01
This paper makes persuasive demonstrations on some problems about the human ear sound transmission principle in existing physiological textbooks and reference books, and puts forward the authors' view to make up for its literature. Exerting the knowledge of lever in physics and the acoustics theory, we come up with an equivalent simplified model of manubrium mallei which is to meet the requirements as the long arm of the lever. We also set up an equivalent simplified model of ossicular chain--a combination of levers of ossicular chain. We disassemble the model into two simple levers, and make full analysis and demonstration on them. Through the calculation and comparison of displacement amplitudes in both external auditory canal air and internal ear lymph, we may draw a conclusion that the key reason, which the sound displacement amplitude is to be decreased to adapt to the endurance limit of the basement membrane, is that the density and sound speed in lymph is much higher than those in the air.
Vibrotactile perception and effects of short-term exposure to hand-arm vibration.
Burström, Lage; Lundström, Ronnie; Hagberg, Mats; Nilsson, Tohr
2009-07-01
This study clarifies whether the established frequency weighting procedure for evaluating exposure to hand-transmitted vibration can effectively evaluate the temporary changes in vibrotactile perception thresholds due to pre-exposure to vibration. In addition, this study investigates the relationship between changes of the vibrotactile perception thresholds and the normalized energy-equivalent frequency-weighted acceleration. The fingers of 10 healthy subjects, five male and five female, were exposed to vibration under 16 conditions with a combination of different frequencies, intensities, and exposure times. The vibration frequencies were 31.5 and 125 Hz and exposure lasted between 2 and 16 min. According to International Organization for Standardization (ISO) 5349-1, the energy-equivalent frequency-weighted acceleration for the experimental time of 16 min is 2.5 or 5.0 m s(-2) root-mean-square, corresponding to a 8-h equivalent acceleration, A(8), of approximately 0.5 and 0.9 m s(-2), respectively. A measure of the vibrotactile perception thresholds was conducted before the different exposures to vibration. Immediately after the vibration exposure, the acute effect was measured continuously on the exposed index finger for the first 75 s, followed by 30 s of measures every minute for a maximum of 10 min. If the subject's thresholds had not recovered, the measures continued for a maximum of 30 min with measurements taken every 5 min. Pre-exposure to vibration significantly influenced vibrotactile thresholds. This study concludes that the influence on the thresholds depends on the frequency of the vibration stimuli. Increased equivalent frequency-weighted acceleration resulted in a significant change in threshold, but the thresholds were unaffected when changes in the vibration magnitude were expressed as the frequency-weighted acceleration or the unweighted acceleration. Moreover, the frequency of the pre-vibration exposure significantly influenced (up to 25 min after exposure) recovery time of the vibrotactile thresholds. This study shows that the frequency weighting procedure in ISO 5349-1 is unable to predict the produced acute changes in the vibrotactile perception. Moreover, the results imply that the calculation of the 'energy-equivalent' frequency-weighted acceleration does not reflect the acute changes of the vibration perception thresholds due to pre-exposure to vibration. Furthermore, when testing for the vibrotactile thresholds, exposure to vibration on the day of a test might influence the results. Until further knowledge is obtained, the previous practice of 3 h avoidance of vibration exposure before assessment is recommended.
Auditory sensitivity of seals and sea lions in complex listening scenarios.
Cunningham, Kane A; Southall, Brandon L; Reichmuth, Colleen
2014-12-01
Standard audiometric data, such as audiograms and critical ratios, are often used to inform marine mammal noise-exposure criteria. However, these measurements are obtained using simple, artificial stimuli-i.e., pure tones and flat-spectrum noise-while natural sounds typically have more complex structure. In this study, detection thresholds for complex signals were measured in (I) quiet and (II) masked conditions for one California sea lion (Zalophus californianus) and one harbor seal (Phoca vitulina). In Experiment I, detection thresholds in quiet conditions were obtained for complex signals designed to isolate three common features of natural sounds: Frequency modulation, amplitude modulation, and harmonic structure. In Experiment II, detection thresholds were obtained for the same complex signals embedded in two types of masking noise: Synthetic flat-spectrum noise and recorded shipping noise. To evaluate how accurately standard hearing data predict detection of complex sounds, the results of Experiments I and II were compared to predictions based on subject audiograms and critical ratios combined with a basic hearing model. Both subjects exhibited greater-than-predicted sensitivity to harmonic signals in quiet and masked conditions, as well as to frequency-modulated signals in masked conditions. These differences indicate that the complex features of naturally occurring sounds enhance detectability relative to simple stimuli.
Exploration of the psychophysics of a motion displacement hyperacuity stimulus.
Verdon-Roe, Gay Mary; Westcott, Mark C; Viswanathan, Ananth C; Fitzke, Frederick W; Garway-Heath, David F
2006-11-01
To explore the summation properties of a motion-displacement hyperacuity stimulus with respect to stimulus area and luminance, with the goal of applying the results to the development of a motion-displacement test (MDT) for the detection of early glaucoma. A computer-generated line stimulus was presented with displacements randomized between 0 and 40 minutes of arc (min arc). Displacement thresholds (50% seen) were compared for stimuli of equal area but different edge length (orthogonal to the direction of motion) at four retinal locations. Also, MDT thresholds were recorded at five values of Michelson contrast (25%-84%) for each of five line lengths (11-128 min arc) at a single nasal location (-27,3). Frequency-of-seeing (FOS) curves were generated and displacement thresholds and interquartile ranges (IQR, 25%-75% seen) determined by probit analysis. Equivalent displacement thresholds were found for stimuli of equal area but half the edge length. Elevations of thresholds and IQR were demonstrated as line length and contrast were reduced. Equivalent displacement thresholds were also found for stimuli of equivalent energy (stimulus area x [stimulus luminance - background luminance]), in accordance with Ricco's law. There was a linear relationship (slope -0.5) between log MDT threshold and log stimulus energy. Stimulus area, rather than edge length, determined displacement thresholds within the experimental conditions tested. MDT thresholds are linearly related to the square root of the total energy of the stimulus. A new law, the threshold energy-displacement (TED) law, is proposed to apply to MDT summation properties, giving the relationship T = K logE where, T is the MDT threshold, Kis the constant, and E is the stimulus energy.
Spiking Models for Level-Invariant Encoding
Brette, Romain
2012-01-01
Levels of ecological sounds vary over several orders of magnitude, but the firing rate and membrane potential of a neuron are much more limited in range. In binaural neurons of the barn owl, tuning to interaural delays is independent of level differences. Yet a monaural neuron with a fixed threshold should fire earlier in response to louder sounds, which would disrupt the tuning of these neurons. How could spike timing be independent of input level? Here I derive theoretical conditions for a spiking model to be insensitive to input level. The key property is a dynamic change in spike threshold. I then show how level invariance can be physiologically implemented, with specific ionic channel properties. It appears that these ingredients are indeed present in monaural neurons of the sound localization pathway of birds and mammals. PMID:22291634
Optimization of programming parameters in children with the advanced bionics cochlear implant.
Baudhuin, Jacquelyn; Cadieux, Jamie; Firszt, Jill B; Reeder, Ruth M; Maxson, Jerrica L
2012-05-01
Cochlear implants provide access to soft intensity sounds and therefore improved audibility for children with severe-to-profound hearing loss. Speech processor programming parameters, such as threshold (or T-level), input dynamic range (IDR), and microphone sensitivity, contribute to the recipient's program and influence audibility. When soundfield thresholds obtained through the speech processor are elevated, programming parameters can be modified to improve soft sound detection. Adult recipients show improved detection for low-level sounds when T-levels are set at raised levels and show better speech understanding in quiet when wider IDRs are used. Little is known about the effects of parameter settings on detection and speech recognition in children using today's cochlear implant technology. The overall study aim was to assess optimal T-level, IDR, and sensitivity settings in pediatric recipients of the Advanced Bionics cochlear implant. Two experiments were conducted. Experiment 1 examined the effects of two T-level settings on soundfield thresholds and detection of the Ling 6 sounds. One program set T-levels at 10% of most comfortable levels (M-levels) and another at 10 current units (CUs) below the level judged as "soft." Experiment 2 examined the effects of IDR and sensitivity settings on speech recognition in quiet and noise. Participants were 11 children 7-17 yr of age (mean 11.3) implanted with the Advanced Bionics High Resolution 90K or CII cochlear implant system who had speech recognition scores of 20% or greater on a monosyllabic word test. Two T-level programs were compared for detection of the Ling sounds and frequency modulated (FM) tones. Differing IDR/sensitivity programs (50/0, 50/10, 70/0, 70/10) were compared using Ling and FM tone detection thresholds, CNC (consonant-vowel nucleus-consonant) words at 50 dB SPL, and Hearing in Noise Test for Children (HINT-C) sentences at 65 dB SPL in the presence of four-talker babble (+8 signal-to-noise ratio). Outcomes were analyzed using a paired t-test and a mixed-model repeated measures analysis of variance (ANOVA). T-levels set 10 CUs below "soft" resulted in significantly lower detection thresholds for all six Ling sounds and FM tones at 250, 1000, 3000, 4000, and 6000 Hz. When comparing programs differing by IDR and sensitivity, a 50 dB IDR with a 0 sensitivity setting showed significantly poorer thresholds for low frequency FM tones and voiced Ling sounds. Analysis of group mean scores for CNC words in quiet or HINT-C sentences in noise indicated no significant differences across IDR/sensitivity settings. Individual data, however, showed significant differences between IDR/sensitivity programs in noise; the optimal program differed across participants. In pediatric recipients of the Advanced Bionics cochlear implant device, manually setting T-levels with ascending loudness judgments should be considered when possible or when low-level sounds are inaudible. Study findings confirm the need to determine program settings on an individual basis as well as the importance of speech recognition verification measures in both quiet and noise. Clinical guidelines are suggested for selection of programming parameters in both young and older children. American Academy of Audiology.
Residual Inhibition Functions Overlap Tinnitus Spectra and the Region of Auditory Threshold Shift
Moffat, Graeme; Baumann, Michael; Ward, Lawrence M.
2008-01-01
Animals exposed to noise trauma show augmented synchronous neural activity in tonotopically reorganized primary auditory cortex consequent on hearing loss. Diminished intracortical inhibition in the reorganized region appears to enable synchronous network activity that develops when deafferented neurons begin to respond to input via their lateral connections. In humans with tinnitus accompanied by hearing loss, this process may generate a phantom sound that is perceived in accordance with the location of the affected neurons in the cortical place map. The neural synchrony hypothesis predicts that tinnitus spectra, and heretofore unmeasured “residual inhibition functions” that relate residual tinnitus suppression to the center frequency of masking sounds, should cover the region of hearing loss in the audiogram. We confirmed these predictions in two independent cohorts totaling 90 tinnitus subjects, using computer-based tools designed to assess the psychoacoustic properties of tinnitus. Tinnitus spectra and residual inhibition functions for depth and duration increased with the amount of threshold shift over the region of hearing impairment. Residual inhibition depth was shallower when the masking sounds that were used to induce residual inhibition showed decreased correspondence with the frequency spectrum and bandwidth of the tinnitus. These findings suggest that tinnitus and its suppression in residual inhibition depend on processes that span the region of hearing impairment and not on mechanisms that enhance cortical representations for sound frequencies at the audiometric edge. Hearing thresholds measured in age-matched control subjects without tinnitus implicated hearing loss as a factor in tinnitus, although elevated thresholds alone were not sufficient to cause tinnitus. PMID:18712566
Dance, Stephen; Backus, Bradford; Morales, Lorenzo
2018-01-01
Introduction: The effect of a sound reinforcement system, in terms of speech intelligibility, has been systematically determined under realistic conditions. Different combinations of ambient and reverberant conditions representative of a classroom environment have been investigated. Materials and Methods: By comparing the measured speech transmission index metric with and without the system in the same space under different room acoustics conditions, it was possible to determine when the system was most effective. A new simple criterion, equivalent noise reduction (ENR), was introduced to determine the effectiveness of the sound reinforcement system which can be used to predict the speech transmission index based on the ambient sound pressure and reverberation time with and without amplification. Results: This criterion had a correlation, R2 > 0.97. It was found that sound reinforcement provided no benefit if the competing noise level was less than 40 dBA. However, the maximum benefit of such a system was equivalent to a 7.7 dBA noise reduction. Conclusion: Using the ENR model, it would be possible to determine the suitability of implementing sound reinforcement systems in any room, thus providing a tool to determine if natural acoustic treatment or sound field amplification would be of most benefit to the occupants of any particular room. PMID:29785972
Dance, Stephen; Backus, Bradford; Morales, Lorenzo
2018-01-01
The effect of a sound reinforcement system, in terms of speech intelligibility, has been systematically determined under realistic conditions. Different combinations of ambient and reverberant conditions representative of a classroom environment have been investigated. By comparing the measured speech transmission index metric with and without the system in the same space under different room acoustics conditions, it was possible to determine when the system was most effective. A new simple criterion, equivalent noise reduction (ENR), was introduced to determine the effectiveness of the sound reinforcement system which can be used to predict the speech transmission index based on the ambient sound pressure and reverberation time with and without amplification. This criterion had a correlation, R 2 > 0.97. It was found that sound reinforcement provided no benefit if the competing noise level was less than 40 dBA. However, the maximum benefit of such a system was equivalent to a 7.7 dBA noise reduction. Using the ENR model, it would be possible to determine the suitability of implementing sound reinforcement systems in any room, thus providing a tool to determine if natural acoustic treatment or sound field amplification would be of most benefit to the occupants of any particular room.
A Psychophysical Evaluation of Spectral Enhancement
ERIC Educational Resources Information Center
DiGiovanni, Jeffrey J.; Nelson, Peggy B.; Schlauch, Robert S.
2005-01-01
Listeners with sensorineural hearing loss have well-documented elevated hearing thresholds; reduced auditory dynamic ranges; and reduced spectral (or frequency) resolution that may reduce speech intelligibility, especially in the presence of competing sounds. Amplification and amplitude compression partially compensate for elevated thresholds and…
Broadband noise exposure does not affect hearing sensitivity in big brown bats (Eptesicus fuscus).
Simmons, Andrea Megela; Hom, Kelsey N; Warnecke, Michaela; Simmons, James A
2016-04-01
In many vertebrates, exposure to intense sounds under certain stimulus conditions can induce temporary threshold shifts that reduce hearing sensitivity. Susceptibility to these hearing losses may reflect the relatively quiet environments in which most of these species have evolved. Echolocating big brown bats (Eptesicus fuscus) live in extremely intense acoustic environments in which they navigate and forage successfully, both alone and in company with other bats. We hypothesized that bats may have evolved a mechanism to minimize noise-induced hearing losses that otherwise could impair natural echolocation behaviors. The hearing sensitivity of seven big brown bats was measured in active echolocation and passive hearing tasks, before and after exposure to broadband noise spanning their audiometric range (10-100 kHz, 116 dB SPL re. 20 µPa rms, 1 h duration; sound exposure level 152 dB). Detection thresholds measured 20 min, 2 h or 24 h after exposure did not vary significantly from pre-exposure thresholds or from thresholds in control (sham exposure) conditions. These results suggest that big brown bats may be less susceptible to temporary threshold shifts than are other terrestrial mammals after exposure to similarly intense broadband sounds. These experiments provide fertile ground for future research on possible mechanisms employed by echolocating bats to minimize hearing losses while orienting effectively in noisy biological soundscapes. © 2016. Published by The Company of Biologists Ltd.
Auditory velocity discrimination in the horizontal plane at very high velocities.
Frissen, Ilja; Féron, François-Xavier; Guastavino, Catherine
2014-10-01
We determined velocity discrimination thresholds and Weber fractions for sounds revolving around the listener at very high velocities. Sounds used were a broadband white noise and two harmonic sounds with fundamental frequencies of 330 Hz and 1760 Hz. Experiment 1 used velocities ranging between 288°/s and 720°/s in an acoustically treated room and Experiment 2 used velocities between 288°/s and 576°/s in a highly reverberant hall. A third experiment addressed potential confounds in the first two experiments. The results show that people can reliably discriminate velocity at very high velocities and that both thresholds and Weber fractions decrease as velocity increases. These results violate Weber's law but are consistent with the empirical trend observed in the literature. While thresholds for the noise and 330 Hz harmonic stimulus were similar, those for the 1760 Hz harmonic stimulus were substantially higher. There were no reliable differences in velocity discrimination between the two acoustical environments, suggesting that auditory motion perception at high velocities is robust against the effects of reverberation. Copyright © 2014 Elsevier B.V. All rights reserved.
Spatial sound field synthesis and upmixing based on the equivalent source method.
Bai, Mingsian R; Hsu, Hoshen; Wen, Jheng-Ciang
2014-01-01
Given scarce number of recorded signals, spatial sound field synthesis with an extended sweet spot is a challenging problem in acoustic array signal processing. To address the problem, a synthesis and upmixing approach inspired by the equivalent source method (ESM) is proposed. The synthesis procedure is based on the pressure signals recorded by a microphone array and requires no source model. The array geometry can also be arbitrary. Four upmixing strategies are adopted to enhance the resolution of the reproduced sound field when there are more channels of loudspeakers than the microphones. Multi-channel inverse filtering with regularization is exploited to deal with the ill-posedness in the reconstruction process. The distance between the microphone and loudspeaker arrays is optimized to achieve the best synthesis quality. To validate the proposed system, numerical simulations and subjective listening experiments are performed. The results demonstrated that all upmixing methods improved the quality of reproduced target sound field over the original reproduction. In particular, the underdetermined ESM interpolation method yielded the best spatial sound field synthesis in terms of the reproduction error, timbral quality, and spatial quality.
NASA Astrophysics Data System (ADS)
Breitzke, Monika; Bohlen, Thomas
2010-05-01
Modelling sound propagation in the ocean is an essential tool to assess the potential risk of air-gun shots on marine mammals. Based on a 2.5-D finite-difference code a full waveform modelling approach is presented, which determines both sound exposure levels of single shots and cumulative sound exposure levels of multiple shots fired along a seismic line. Band-limited point source approximations of compact air-gun clusters deployed by R/V Polarstern in polar regions are used as sound sources. Marine mammals are simulated as static receivers. Applications to deep and shallow water models including constant and depth-dependent sound velocity profiles of the Southern Ocean show dipole-like directivities in case of single shots and tubular cumulative sound exposure level fields beneath the seismic line in case of multiple shots. Compared to a semi-infinite model an incorporation of seafloor reflections enhances the seismically induced noise levels close to the sea surface. Refraction due to sound velocity gradients and sound channelling in near-surface ducts are evident, but affect only low to moderate levels. Hence, exposure zone radii derived for different hearing thresholds are almost independent of the sound velocity structure. With decreasing thresholds radii increase according to a spherical 20 log10 r law in case of single shots and according to a cylindrical 10 log10 r law in case of multiple shots. A doubling of the shot interval diminishes the cumulative sound exposure levels by -3 dB and halves the radii. The ocean bottom properties only slightly affect the radii in shallow waters, if the normal incidence reflection coefficient exceeds 0.2.
Inquiring Ears Want to Know: A Fact Sheet about Your Hearing Test
... track changes in hearing over time • Your hearing threshold levels (the quietest sounds you can hear) are ... Do I have normal hearing? Compare your hearing threshold levels to this scale: -10 – 25 dB 26 – ...
2017-01-01
Purpose This review provides clinicians with an overview of recent findings relevant to understanding why listeners with normal hearing thresholds (NHTs) sometimes suffer from communication difficulties in noisy settings. Method The results from neuroscience and psychoacoustics are reviewed. Results In noisy settings, listeners focus their attention by engaging cortical brain networks to suppress unimportant sounds; they then can analyze and understand an important sound, such as speech, amidst competing sounds. Differences in the efficacy of top-down control of attention can affect communication abilities. In addition, subclinical deficits in sensory fidelity can disrupt the ability to perceptually segregate sound sources, interfering with selective attention, even in listeners with NHTs. Studies of variability in control of attention and in sensory coding fidelity may help to isolate and identify some of the causes of communication disorders in individuals presenting at the clinic with “normal hearing.” Conclusions How well an individual with NHTs can understand speech amidst competing sounds depends not only on the sound being audible but also on the integrity of cortical control networks and the fidelity of the representation of suprathreshold sound. Understanding the root cause of difficulties experienced by listeners with NHTs ultimately can lead to new, targeted interventions that address specific deficits affecting communication in noise. Presentation Video http://cred.pubs.asha.org/article.aspx?articleid=2601617 PMID:29049598
40 CFR 98.231 - Reporting threshold.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Reporting threshold. 98.231 Section 98...) MANDATORY GREENHOUSE GAS REPORTING Petroleum and Natural Gas Systems § 98.231 Reporting threshold. (a) You... § 98.232(i) emit 25,000 metric tons of CO2 equivalent or more per year. (b) For applying the threshold...
A critical review of the potential impacts of marine seismic surveys on fish & invertebrates.
Carroll, A G; Przeslawski, R; Duncan, A; Gunning, M; Bruce, B
2017-01-15
Marine seismic surveys produce high intensity, low-frequency impulsive sounds at regular intervals, with most sound produced between 10 and 300Hz. Offshore seismic surveys have long been considered to be disruptive to fisheries, but there are few ecological studies that target commercially important species, particularly invertebrates. This review aims to summarise scientific studies investigating the impacts of low-frequency sound on marine fish and invertebrates, as well as to critically evaluate how such studies may apply to field populations exposed to seismic operations. We focus on marine seismic surveys due to their associated unique sound properties (i.e. acute, low-frequency, mobile source locations), as well as fish and invertebrates due to the commercial value of many species in these groups. The main challenges of seismic impact research are the translation of laboratory results to field populations over a range of sound exposure scenarios and the lack of sound exposure standardisation which hinders the identification of response thresholds. An integrated multidisciplinary approach to manipulative and in situ studies is the most effective way to establish impact thresholds in the context of realistic exposure levels, but if that is not practical the limitations of each approach must be carefully considered. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ramsauer, N.; Robert, D.
The phonotactic capacity of tachinid flies to acoustically detect and localize a sound source simulating their cricket host was investigated in a large flight room. Acoustic measurements were performed to estimate the actual stimulus delivered to the flies, revealing highly heterogeneous sound fields. When presented with a simulated cricket song in red or infrared light conditions, the flies readily flew to the sound source and landed on it. Behavioural phonotactic thresholds were established as a function of carrier frequency and were found to coincide well with the frequency of the host's natural song (4.5-5.2kHz). Experiments revealed that the same range of frequencies is preferentially attractive to the free-flying flies, and that the reliability of signal detection in the presence of noise is best at behaviourally relevant frequencies.
Threshold and Beyond: Modeling The Intensity Dependence of Auditory Responses
2007-01-01
In many studies of auditory-evoked responses to low-intensity sounds, the response amplitude appears to increase roughly linearly with the sound level in decibels (dB), corresponding to a logarithmic intensity dependence. But the auditory system is assumed to be linear in the low-intensity limit. The goal of this study was to resolve the seeming contradiction. Based on assumptions about the rate-intensity functions of single auditory-nerve fibers and the pattern of cochlear excitation caused by a tone, a model for the gross response of the population of auditory nerve fibers was developed. In accordance with signal detection theory, the model denies the existence of a threshold. This implies that regarding the detection of a significant stimulus-related effect, a reduction in sound intensity can always be compensated for by increasing the measurement time, at least in theory. The model suggests that the gross response is proportional to intensity when the latter is low (range I), and a linear function of sound level at higher intensities (range III). For intensities in between, it is concluded that noisy experimental data may provide seemingly irrefutable evidence of a linear dependence on sound pressure (range II). In view of the small response amplitudes that are to be expected for intensity range I, direct observation of the predicted proportionality with intensity will generally be a challenging task for an experimenter. Although the model was developed for the auditory nerve, the basic conclusions are probably valid for higher levels of the auditory system, too, and might help to improve models for loudness at threshold. PMID:18008105
Execution of deep dipole geoelectrical soundings in areas of geothermal interest. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patella, D.
It is suggested that deep geoelectrical problems may be resolved by carrying out dipole soundings in the field and applying a quantitative interpretation in the Schlumberger domain. The 'transformation' of original field dipole sounding curves into equivalent Schlumberger curves is outlined for the cases of layered structures and arbitrary underground structures. Theoretical apparent resistivity curves are derived for soundings over bidimensional structures. Following a summary of the geological features of the Travale-Radicondoli geothermal area of Italy, the dipole sounding method employed for this field study and the means of collecting and analyzing the data, are outlined.
Individual Differences Reveal Correlates of Hidden Hearing Deficits
Masud, Salwa; Mehraei, Golbarg; Verhulst, Sarah; Shinn-Cunningham, Barbara G.
2015-01-01
Clinical audiometry has long focused on determining the detection thresholds for pure tones, which depend on intact cochlear mechanics and hair cell function. Yet many listeners with normal hearing thresholds complain of communication difficulties, and the causes for such problems are not well understood. Here, we explore whether normal-hearing listeners exhibit such suprathreshold deficits, affecting the fidelity with which subcortical areas encode the temporal structure of clearly audible sound. Using an array of measures, we evaluated a cohort of young adults with thresholds in the normal range to assess both cochlear mechanical function and temporal coding of suprathreshold sounds. Listeners differed widely in both electrophysiological and behavioral measures of temporal coding fidelity. These measures correlated significantly with each other. Conversely, these differences were unrelated to the modest variation in otoacoustic emissions, cochlear tuning, or the residual differences in hearing threshold present in our cohort. Electroencephalography revealed that listeners with poor subcortical encoding had poor cortical sensitivity to changes in interaural time differences, which are critical for localizing sound sources and analyzing complex scenes. These listeners also performed poorly when asked to direct selective attention to one of two competing speech streams, a task that mimics the challenges of many everyday listening environments. Together with previous animal and computational models, our results suggest that hidden hearing deficits, likely originating at the level of the cochlear nerve, are part of “normal hearing.” PMID:25653371
NASA Astrophysics Data System (ADS)
Abbasi, Milad; Monnazzam, Mohammad Reza; Zakerian, Sayedabbolfazl; Yousefzadeh, Arsalan
2015-04-01
Noise from wind turbines is one of the most important factors affecting the health, welfare, and human sleep. This research was carried out to study the effect of wind turbine noise on workers' sleep disorder. For this, Manjil Wind Farm, because of the greater number of staff and turbines than other wind farms in Iran, was chosen as case study. A total number of 53 participants took part in this survey. They were classified into three groups of mechanics, security, and official. In this study, daytime sleepiness data of workers were gathered using Epworth Sleepiness Scales (ESS) was used to determine the level of daytime sleepiness among the workers. The 8-h equivalent sound level (LAeq,8h) was measured to determine the individuals' exposure at each occupational group. Finally, the effect of sound, age, and workers' experience on individuals' sleep disorder was analyzed through multiple regression analysis in the R software. The results showed that there was a positive and significant relationship between age, workers' experience, equivalent sound level, and the level of sleep disorder. When age is constant, sleep disorder will increase by 26% as per each 1 dB increase in equivalent sound level. In situations where equivalent sound level is constant, an increase of 17% in sleep disorder is occurred as per each year of work experience. Because of the difference in sound exposure in different occupational groups. The effect of noise in repairing group was about 6.5 times of official group and also 3.4 times of the security group. Sleep disorder effect caused by wind turbine noise in the security group is almost two times more than the official group. Unlike most studies on wind turbine noise that address the sleep disorder among inhabitants nearby wind farms, this study, for the first time in the world, examines the impact of wind turbine noise on sleep disorder of workers who are more closer to wind turbines and exposed to higher levels of noise. So despite all the good benefits of wind turbines, it can be stated that this technology has health risks for all those exposed to its sound. However, further research is needed to confirm the results of this study.
Exposure to excessive sounds and hearing status in academic classical music students.
Pawlaczyk-Łuszczyńska, Małgorzata; Zamojska-Daniszewska, Małgorzata; Dudarewicz, Adam; Zaborowski, Kamil
2017-02-21
The aim of this study was to assess hearing of music students in relation to their exposure to excessive sounds. Standard pure-tone audiometry (PTA) was performed in 168 music students, aged 22.5±2.5 years. The control group included 67 subjects, non-music students and non-musicians, aged 22.8±3.3 years. Data on the study subjects' musical experience, instruments in use, time of weekly practice and additional risk factors for noise-induced hearing loss (NIHL) were identified by means of a questionnaire survey. Sound pressure levels produced by various groups of instruments during solo and group playing were also measured and analyzed. The music students' audiometric hearing threshold levels (HTLs) were compared with the theoretical predictions calculated according to the International Organization for Standardization standard ISO 1999:2013. It was estimated that the music students were exposed for 27.1±14.3 h/week to sounds at the A-weighted equivalent-continuous sound pressure level of 89.9±6.0 dB. There were no significant differences in HTLs between the music students and the control group in the frequency range of 4000-8000 Hz. Furthermore, in each group HTLs in the frequency range 1000-8000 Hz did not exceed 20 dB HL in 83% of the examined ears. Nevertheless, high frequency notched audiograms typical of the noise-induced hearing loss were found in 13.4% and 9% of the musicians and non-musicians, respectively. The odds ratio (OR) of notching in the music students increased significantly along with higher sound pressure levels (OR = 1.07, 95% confidence interval (CI): 1.014-1.13, p < 0.05). The students' HTLs were worse (higher) than those of a highly screened non-noise-exposed population. Moreover, their hearing loss was less severe than that expected from sound exposure for frequencies of 3000 Hz and 4000 Hz, and it was more severe in the case of frequency of 6000 Hz. The results confirm the need for further studies and development of a hearing conservation program for music students. Int J Occup Med Environ Health 2017;30(1):55-75. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Equivalent Noise Dose Obtained through Hearing Aids in the Classrooms of Hearing-Impaired Children.
ERIC Educational Resources Information Center
Wilde, Ronald A.
1990-01-01
A commercial noise dose meter was used to estimate the equivalent noise dose received through high-gain hearing aids worn in four classrooms in a school for deaf children. There were no significant differences among nominal saturation sound pressure level (SSPL) settings, and all SSPL settings produced very high equivalent noise doses. (Author/JDD)
Murphy, William J; Flamme, Gregory A; Campbell, Adam R; Zechmann, Edward L; Tasko, Stephen M; Lankford, James E; Meinke, Deanna K; Finan, Donald S; Stewart, Michael
2018-02-01
This research assessed the reduction of peak levels, equivalent energy and sound power of firearm suppressors. The first study evaluated the effect of three suppressors at four microphone positions around four firearms. The second study assessed the suppressor-related reduction of sound power with a 3 m hemispherical microphone array for two firearms. The suppressors reduced exposures at the ear between 17 and 24 dB peak sound pressure level and reduced the 8 h equivalent A-weighted energy between 9 and 21 dB depending upon the firearm and ammunition. Noise reductions observed for the instructor's position about a metre behind the shooter were between 20 and 28 dB peak sound pressure level and between 11 and 26 dB L Aeq,8h . Firearm suppressors reduced the measured sound power levels between 2 and 23 dB. Sound power reductions were greater for the low-velocity ammunition than for the same firearms fired with high-velocity ammunition due to the effect of N-waves produced by a supersonic bullet. Firearm suppressors may reduce noise exposure, and the cumulative exposures of suppressed firearms can still present a significant hearing risk. Therefore, firearm users should always wear hearing protection whenever target shooting or hunting.
Hadjiaghai, Oliwia; Ladich, Friedrich
2015-01-01
Background Data on sex-specific differences in sound production, acoustic behaviour and hearing abilities in fishes are rare. Representatives of numerous catfish families are known to produce sounds in agonistic contexts (intraspecific aggression and interspecific disturbance situations) using their pectoral fins. The present study investigates differences in agonistic behaviour, sound production and hearing abilities in males and females of a callichthyid catfish. Methodology/Principal Findings Eight males and nine females of the armoured catfish Megalechis thoracata were investigated. Agonistic behaviour displayed during male-male and female-female dyadic contests and sounds emitted were recorded, sound characteristics analysed and hearing thresholds measured using the auditory evoked potential (AEP) recording technique. Male pectoral spines were on average 1.7-fold longer than those of same-sized females. Visual and acoustic threat displays differed between sexes. Males produced low-frequency harmonic barks at longer distances and thumps at close distances, whereas females emitted broad-band pulsed crackles when close to each other. Female aggressive sounds were significantly shorter than those of males (167 ms versus 219 to 240 ms) and of higher dominant frequency (562 Hz versus 132 to 403 Hz). Sound duration and sound level were positively correlated with body and pectoral spine length, but dominant frequency was inversely correlated only to spine length. Both sexes showed a similar U-shaped hearing curve with lowest thresholds between 0.2 and 1 kHz and a drop in sensitivity above 1 kHz. The main energies of sounds were located at the most sensitive frequencies. Conclusions/Significance Current data demonstrate that both male and female M. thoracata produce aggressive sounds, but the behavioural contexts and sound characteristics differ between sexes. Sexes do not differ in hearing, but it remains to be clarified if this is a general pattern among fish. This is the first study to describe sex-specific differences in agonistic behaviour in fishes. PMID:25775458
Threshold for onset of injury in Chinook salmon from exposure to impulsive pile driving sounds.
Halvorsen, Michele B; Casper, Brandon M; Woodley, Christa M; Carlson, Thomas J; Popper, Arthur N
2012-01-01
The risk of effects to fishes and other aquatic life from impulsive sound produced by activities such as pile driving and seismic exploration is increasing throughout the world, particularly with the increased exploitation of oceans for energy production. At the same time, there are few data that provide insight into the effects of these sounds on fishes. The goal of this study was to provide quantitative data to define the levels of impulsive sound that could result in the onset of barotrauma to fish. A High Intensity Controlled Impedance Fluid filled wave Tube was developed that enabled laboratory simulation of high-energy impulsive sound that were characteristic of aquatic far-field, plane-wave acoustic conditions. The sounds used were based upon the impulsive sounds generated by an impact hammer striking a steel shell pile. Neutrally buoyant juvenile Chinook salmon (Oncorhynchus tshawytscha) were exposed to impulsive sounds and subsequently evaluated for barotrauma injuries. Observed injuries ranged from mild hematomas at the lowest sound exposure levels to organ hemorrhage at the highest sound exposure levels. Frequency of observed injuries were used to compute a biological response weighted index (RWI) to evaluate the physiological impact of injuries at the different exposure levels. As single strike and cumulative sound exposure levels (SEL(ss), SEL(cum) respectively) increased, RWI values increased. Based on the results, tissue damage associated with adverse physiological costs occurred when the RWI was greater than 2. In terms of sound exposure levels a RWI of 2 was achieved for 1920 strikes by 177 dB re 1 µPa(2)⋅s SEL(ss) yielding a SEL(cum) of 210 dB re 1 µPa(2)⋅s, and for 960 strikes by 180 dB re 1 µPa(2)⋅s SEL(ss) yielding a SEL(cum) of 210 dB re 1 µPa(2)⋅s. These metrics define thresholds for onset of injury in juvenile Chinook salmon.
Threshold for Onset of Injury in Chinook Salmon from Exposure to Impulsive Pile Driving Sounds
Halvorsen, Michele B.; Casper, Brandon M.; Woodley, Christa M.; Carlson, Thomas J.; Popper, Arthur N.
2012-01-01
The risk of effects to fishes and other aquatic life from impulsive sound produced by activities such as pile driving and seismic exploration is increasing throughout the world, particularly with the increased exploitation of oceans for energy production. At the same time, there are few data that provide insight into the effects of these sounds on fishes. The goal of this study was to provide quantitative data to define the levels of impulsive sound that could result in the onset of barotrauma to fish. A High Intensity Controlled Impedance Fluid filled wave Tube was developed that enabled laboratory simulation of high-energy impulsive sound that were characteristic of aquatic far-field, plane-wave acoustic conditions. The sounds used were based upon the impulsive sounds generated by an impact hammer striking a steel shell pile. Neutrally buoyant juvenile Chinook salmon (Oncorhynchus tshawytscha) were exposed to impulsive sounds and subsequently evaluated for barotrauma injuries. Observed injuries ranged from mild hematomas at the lowest sound exposure levels to organ hemorrhage at the highest sound exposure levels. Frequency of observed injuries were used to compute a biological response weighted index (RWI) to evaluate the physiological impact of injuries at the different exposure levels. As single strike and cumulative sound exposure levels (SELss, SELcum respectively) increased, RWI values increased. Based on the results, tissue damage associated with adverse physiological costs occurred when the RWI was greater than 2. In terms of sound exposure levels a RWI of 2 was achieved for 1920 strikes by 177 dB re 1 µPa2⋅s SELss yielding a SELcum of 210 dB re 1 µPa2⋅s, and for 960 strikes by 180 dB re 1 µPa2⋅s SELss yielding a SELcum of 210 dB re 1 µPa2⋅s. These metrics define thresholds for onset of injury in juvenile Chinook salmon. PMID:22745695
Auditory Sensitivity and Masking Profiles for the Sea Otter (Enhydra lutris).
Ghoul, Asila; Reichmuth, Colleen
2016-01-01
Sea otters are threatened marine mammals that may be negatively impacted by human-generated coastal noise, yet information about sound reception in this species is surprisingly scarce. We investigated amphibious hearing in sea otters by obtaining the first measurements of absolute sensitivity and critical masking ratios. Auditory thresholds were measured in air and underwater from 0.125 to 40 kHz. Critical ratios derived from aerial masked thresholds from 0.25 to 22.6 kHz were also obtained. These data indicate that although sea otters can detect underwater sounds, their hearing appears to be primarily air adapted and not specialized for detecting signals in background noise.
Finneran, J J; Schlundt, C E; Carder, D A; Clark, J A; Young, J A; Gaspin, J B; Ridgway, S H
2000-07-01
A behavioral response paradigm was used to measure masked underwater hearing thresholds in two bottlenose dolphins and one beluga whale before and after exposure to impulsive underwater sounds with waveforms resembling distant signatures of underwater explosions. An array of piezoelectric transducers was used to generate impulsive sounds with waveforms approximating those predicted from 5 or 500 kg HBX-1 charges at ranges from 1.5 to 55.6 km. At the conclusion of the study, no temporary shifts in masked-hearing thresholds (MTTSs), defined as a 6-dB or larger increase in threshold over pre-exposure levels, had been observed at the highest impulse level generated (500 kg at 1.7 km, peak pressure 70 kPa); however, disruptions of the animals' trained behaviors began to occur at exposures corresponding to 5 kg at 9.3 km and 5 kg at 1.5 km for the dolphins and 500 kg at 1.9 km for the beluga whale. These data are the first direct information regarding the effects of distant underwater explosion signatures on the hearing abilities of odontocetes.
Threshold of the precedence effect in noise
Freyman, Richard L.; Griffin, Amanda M.; Zurek, Patrick M.
2014-01-01
Three effects that show a temporal asymmetry in the influence of interaural cues were studied through the addition of masking noise: (1) The transient precedence effect—the perceptual dominance of a leading transient over a similar lagging transient; (2) the ongoing precedence effect—lead dominance with lead and lag components that extend in time; and (3) the onset capture effect—determination by an onset transient of the lateral position of an otherwise ambiguous extended trailing sound. These three effects were evoked with noise-burst stimuli and were compared in the presence of masking noise. Using a diotic noise masker, detection thresholds for stimuli with lead/lag interaural delays of 0/500 μs were compared to those with 500/0 μs delays. None of the three effects showed a masking difference between those conditions, suggesting that none of the effects is operative at masked threshold. A task requiring the discrimination between stimuli with 500/0 and 0/500 μs interaural delays was used to determine the threshold for each effect in noise. The results showed similar thresholds in noise (10–13 dB SL) for the transient and ongoing precedence effects, but a much higher threshold (33 dB SL) for onset capture of an ambiguous trailing sound. PMID:24815272
Gustafson, Samantha; Pittman, Andrea; Fanning, Robert
2013-06-01
This tutorial demonstrates the effects of tubing length and coupling type (i.e., foam tip or personal earmold) on hearing threshold and real-ear-to-coupler difference (RECD) measures. Hearing thresholds from 0.25 kHz through 8 kHz are reported at various tubing lengths for 28 normal-hearing adults between the ages of 22 and 31 years. RECD values are reported for 14 of the adults. All measures were made with an insert earphone coupled to a standard foam tip and with an insert earphone coupled to each participant's personal earmold. Threshold and RECD measures obtained with a personal earmold were significantly different from those obtained with a foam tip on repeated measures analyses of variance. One-sample t tests showed these differences to vary systematically with increasing tubing length, with the largest average differences (7-8 dB) occurring at 4 kHz. This systematic examination demonstrates the equal and opposite effects of tubing length on threshold and acoustic measures. Specifically, as tubing length increased, sound pressure level in the ear canal decreased, affecting both hearing thresholds and the real-ear portion of the RECDs. This demonstration shows that when the same coupling method is used to obtain the hearing thresholds and RECD, equal and accurate estimates of real-ear sound pressure level are obtained.
Auditory Processing Efficiency and Temporal Resolution in Children and Adults.
ERIC Educational Resources Information Center
Hill, Penelope R.; Hartley, Douglas E.H.; Glasberg, Brian R.; Moore, Brian C.J.; Moore, David R.
2004-01-01
Children have higher auditory backward masking (BM) thresholds than adults. One explanation for this is poor temporal resolution, resulting in difficulty separating brief or rapidly presented sounds. This implies that the auditory temporal window is broader in children than in adults. Alternatively, elevated BM thresholds in children may indicate…
DOT National Transportation Integrated Search
1979-06-01
Temporary threshold shifts were measured repeatedly during a session in order to determine effects of interstimulus interval (ISI) on the shift. The fatiguing sound was a 3-minute, 110-dB-SPL, 4,000-Hz tone. Immediately following the 3-minute stimula...
Brain stem auditory potentials evoked by clicks in the presence of high-pass filtered noise in dogs.
Poncelet, L; Deltenre, P; Coppens, A; Michaux, C; Coussart, E
2006-04-01
This study evaluates the effects of a high-frequency hearing loss simulated by the high-pass-noise masking method, on the click-evoked brain stem-evoked potentials (BAEP) characteristics in dogs. BAEP were obtained in response to rarefaction and condensation click stimuli from 60 dB normal hearing level (NHL, corresponding to 89 dB sound pressure level) to wave V threshold, using steps of 5 dB in eleven 58 to 80-day-old Beagle puppies. Responses were added, providing an equivalent to alternate polarity clicks, and subtracted, providing the rarefaction-condensation potential (RCDP). The procedure was repeated while constant level, high-pass filtered (HPF) noise was superposed to the click. Cut-off frequencies of the successively used filters were 8, 4, 2 and 1 kHz. For each condition, wave V and RCDP thresholds, and slope of the wave V latency-intensity curve (LIC) were collected. The intensity range at which RCDP could not be recorded (pre-RCDP range) was calculated. Compared with the no noise condition, the pre-RCDP range significantly diminished and the wave V threshold significantly increased when the superposed HPF noise reached the 4 kHz area. Wave V LIC slope became significantly steeper with the 2 kHz HPF noise. In this non-invasive model of high-frequency hearing loss, impaired hearing of frequencies from 8 kHz and above escaped detection through click BAEP study in dogs. Frequencies above 13 kHz were however not specifically addressed in this study.
Kauramäki, Jaakko; Jääskeläinen, Iiro P.; Hänninen, Jarno L.; Auranen, Toni; Nummenmaa, Aapo; Lampinen, Jouko; Sams, Mikko
2012-01-01
Selectively attending to task-relevant sounds whilst ignoring background noise is one of the most amazing feats performed by the human brain. Here, we studied the underlying neural mechanisms by recording magnetoencephalographic (MEG) responses of 14 healthy human subjects while they performed a near-threshold auditory discrimination task vs. a visual control task of similar difficulty. The auditory stimuli consisted of notch-filtered continuous noise masker sounds, and of 1020-Hz target tones occasionally () replacing 1000-Hz standard tones of 300-ms duration that were embedded at the center of the notches, the widths of which were parametrically varied. As a control for masker effects, tone-evoked responses were additionally recorded without masker sound. Selective attention to tones significantly increased the amplitude of the onset M100 response at 100 ms to the standard tones during presence of the masker sounds especially with notches narrower than the critical band. Further, attention modulated sustained response most clearly at 300–400 ms time range from sound onset, with narrower notches than in case of the M100, thus selectively reducing the masker-induced suppression of the tone-evoked response. Our results show evidence of a multiple-stage filtering mechanism of sensory input in the human auditory cortex: 1) one at early (100 ms) latencies bilaterally in posterior parts of the secondary auditory areas, and 2) adaptive filtering of attended sounds from task-irrelevant background masker at longer latency (300 ms) in more medial auditory cortical regions, predominantly in the left hemisphere, enhancing processing of near-threshold sounds. PMID:23071654
Gavin, Timothy P; Van Meter, Jessica B; Brophy, Patricia M; Dubis, Gabriel S; Potts, Katlin N; Hickner, Robert C
2012-02-01
It has been proposed that field-based tests (FT) used to estimate functional threshold power (FTP) result in power output (PO) equivalent to PO at lactate threshold (LT). However, anecdotal evidence from regional cycling teams tested for LT in our laboratory suggested that PO at LT underestimated FTP. It was hypothesized that estimated FTP is not equivalent to PO at LT. The LT and estimated FTP were measured in 7 trained male competitive cyclists (VO2max = 65.3 ± 1.6 ml O2·kg(-1)·min(-1)). The FTP was estimated from an 8-minute FT and compared with PO at LT using 2 methods; LT(Δ1), a 1 mmol·L(-1) or greater rise in blood lactate in response to an increase in workload and LT(4.0), blood lactate of 4.0 mmol·L(-1). The estimated FTP was equivalent to PO at LT(4.0) and greater than PO at LT(Δ1). VO2max explained 93% of the variance in individual PO during the 8-minute FT. When the 8-minute FT PO was expressed relative to maximal PO from the VO2max test (individual exercise performance), VO2max explained 64% of the variance in individual exercise performance. The PO at LT was not related to 8-minute FT PO. In conclusion, FTP estimated from an 8-minute FT is equivalent to PO at LT if LT(4.0) is used but is not equivalent for all methods of LT determination including LT(Δ1).
Infant Auditory Sensitivity to Pure Tones and Frequency-Modulated Tones
ERIC Educational Resources Information Center
Leibold, Lori J.; Werner, Lynne A.
2007-01-01
It has been suggested that infants respond preferentially to infant-directed speech because their auditory sensitivity to sounds with extensive frequency modulation (FM) is better than their sensitivity to less modulated sounds. In this experiment, auditory thresholds for FM tones and for unmodulated, or pure, tones in a background of noise were…
Binaural Release from Masking for a Speech Sound in Infants, Preschoolers, and Adults.
ERIC Educational Resources Information Center
Nozza, Robert J.
1988-01-01
Binaural masked thresholds for a speech sound (/ba/) were estimated under two interaural phase conditions in three age groups (infants, preschoolers, adults). Differences as a function of both age and condition and effects of reducing intensity for adults were significant in indicating possible developmental binaural hearing changes, especially…
Christensen-Dalsgaard, Jakob; Brandt, Christian; Willis, Katie L.; Christensen, Christian Bech; Ketten, Darlene; Edds-Walton, Peggy; Fay, Richard R.; Madsen, Peter T.; Carr, Catherine E.
2012-01-01
Turtles, like other amphibious animals, face a trade-off between terrestrial and aquatic hearing. We used laser vibrometry and auditory brainstem responses to measure their sensitivity to vibration stimuli and to airborne versus underwater sound. Turtles are most sensitive to sound underwater, and their sensitivity depends on the large middle ear, which has a compliant tympanic disc attached to the columella. Behind the disc, the middle ear is a large air-filled cavity with a volume of approximately 0.5 ml and a resonance frequency of approximately 500 Hz underwater. Laser vibrometry measurements underwater showed peak vibrations at 500–600 Hz with a maximum of 300 µm s−1 Pa−1, approximately 100 times more than the surrounding water. In air, the auditory brainstem response audiogram showed a best sensitivity to sound of 300–500 Hz. Audiograms before and after removing the skin covering reveal that the cartilaginous tympanic disc shows unchanged sensitivity, indicating that the tympanic disc, and not the overlying skin, is the key sound receiver. If air and water thresholds are compared in terms of sound intensity, thresholds in water are approximately 20–30 dB lower than in air. Therefore, this tympanic ear is specialized for underwater hearing, most probably because sound-induced pulsations of the air in the middle ear cavity drive the tympanic disc. PMID:22438494
Christensen-Dalsgaard, Jakob; Brandt, Christian; Willis, Katie L; Christensen, Christian Bech; Ketten, Darlene; Edds-Walton, Peggy; Fay, Richard R; Madsen, Peter T; Carr, Catherine E
2012-07-22
Turtles, like other amphibious animals, face a trade-off between terrestrial and aquatic hearing. We used laser vibrometry and auditory brainstem responses to measure their sensitivity to vibration stimuli and to airborne versus underwater sound. Turtles are most sensitive to sound underwater, and their sensitivity depends on the large middle ear, which has a compliant tympanic disc attached to the columella. Behind the disc, the middle ear is a large air-filled cavity with a volume of approximately 0.5 ml and a resonance frequency of approximately 500 Hz underwater. Laser vibrometry measurements underwater showed peak vibrations at 500-600 Hz with a maximum of 300 µm s(-1) Pa(-1), approximately 100 times more than the surrounding water. In air, the auditory brainstem response audiogram showed a best sensitivity to sound of 300-500 Hz. Audiograms before and after removing the skin covering reveal that the cartilaginous tympanic disc shows unchanged sensitivity, indicating that the tympanic disc, and not the overlying skin, is the key sound receiver. If air and water thresholds are compared in terms of sound intensity, thresholds in water are approximately 20-30 dB lower than in air. Therefore, this tympanic ear is specialized for underwater hearing, most probably because sound-induced pulsations of the air in the middle ear cavity drive the tympanic disc.
41 CFR 50-204.10 - Occupational noise exposure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... determined as follows: EC21OC91.015 Equivalent sound level contours. Octave band sound pressure levels may be... level dBA slow response 8 90 6 92 4 95 3 97 2 100 11/2 102 1 105 1/2 110 1/4 or less 115 1 When the... not exceed 140 dB peak sound pressure level. [34 FR 7946, May 20, 1969, as amended at 35 FR 1015, Jan...
41 CFR 50-204.10 - Occupational noise exposure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... determined as follows: EC21OC91.015 Equivalent sound level contours. Octave band sound pressure levels may be... level dBA slow response 8 90 6 92 4 95 3 97 2 100 11/2 102 1 105 1/2 110 1/4 or less 115 1 When the... not exceed 140 dB peak sound pressure level. [34 FR 7946, May 20, 1969, as amended at 35 FR 1015, Jan...
Hearing in young adults. Part II: The effects of recreational noise exposure
Keppler, Hannah; Dhooge, Ingeborg; Vinck, Bart
2015-01-01
Great concern arises from recreational noise exposure, which might lead to noise-induced hearing loss in young adults. The objective of the current study was to evaluate the effects of recreational noise exposure on hearing function in young adults. A questionnaire concerning recreational noise exposures and an audiological test battery were completed by 163 subjects (aged 18-30 years). Based on the duration of exposure and self-estimated loudness of various leisure-time activities, the weekly and lifetime equivalent noise exposure were calculated. Subjects were categorized in groups with low, intermediate, and high recreational noise exposure based on these values. Hearing was evaluated using audiometry, transient-evoked otoacoustic emissions (TEOAEs), and distortion-product otoacoustic emissions (DPOAEs). Mean differences in hearing between groups with low, intermediate, and high recreational noise exposure were evaluated using one-way analysis of variance (ANOVA). There were no significant differences in hearing thresholds, TEOAE amplitudes, and DPOAE amplitudes between groups with low, intermediate, or high recreational noise exposure. Nevertheless, one-third of our subjects exceeded the weekly equivalent noise exposure for all activities of 75 dBA. Further, the highest equivalent sound pressure levels (SPLs) were calculated for the activities visiting nightclubs or pubs, attending concerts or festivals, and playing in a band or orchestra. Moreover, temporary tinnitus after recreational noise exposure was found in 86% of our subjects. There were no significant differences in hearing between groups with low, intermediate, and high recreational noise exposure. Nevertheless, a long-term assessment of young adults’ hearing in relation to recreational noise exposure is needed. PMID:26356366
Identification of sleep bruxism with an ambulatory wireless recording system.
Inano, Shinji; Mizumori, Takahiro; Kobayashi, Yasuyoshi; Sumiya, Masakazu; Yatani, Hirofumi
2013-01-01
To examine whether an ambulatory bruxism recording system, including a biologic monitor, that measures sleep variables and sympatho-vagal balance can specifically identify sleep bruxism (SB) at home. Twenty-six volunteers, including 16 SB subjects, were recruited. Each participant recorded his or her electromyogram (EMG), sympatho-vagal balance, and sound level for 3 consecutive nights using an audio-video recorder to identify SB. Data of sleep variables were compared among the 3 experimental nights. The episodes were classified into SB episodes with and without grinding and non-SB episodes. EMG patterns, amplitude, sympatho-vagal balance, and sound level of all episodes were analyzed so as to determine the appropriate thresholds to detect SB episodes and grinding sound. Then, all episodes without video-recording data were classified into SB and non-SB episodes by using the appropriate thresholds, and the sensitivity and specificity to detect SB episodes were calculated. With regard to sleep variables, there were no significant differences except for sleep latency between the first and second nights. The appropriate EMG pattern and thresholds of amplitude, sympatho-vagal balance, and sound level were phasic or mixed EMG pattern, 20% of maximum voluntary contraction, mean + 1 SD, and mean + 2 SDs, respectively. The sensitivity and specificity to detect SB episodes were 88.4% and 74.2%, respectively. The results suggest that this system enables the detection of SB episodes at home with considerably high accuracy and little interference with sleep.
2010-09-01
day-night weighted equivalent sound level Leq equivalent steady sound level m meter(s) m2 square meter(s) m3 cubic meter(s) mi mile(s) mi2 ...widespread and prolonged ice storms have occurred. Based on the data for the 9,130 km2 (3,530 mi2 ) area that includes the NBAFS, less than two...tornadoes occur per year. The localized area effected by a tornado averages only 0.29 km2 (0.11 mi2 ; Ramsdell and Andrews 1986) (ANL 2000). 3.2.2
Tomographic quantum cryptography: equivalence of quantum and classical key distillation.
Bruss, Dagmar; Christandl, Matthias; Ekert, Artur; Englert, Berthold-Georg; Kaszlikowski, Dagomir; Macchiavello, Chiara
2003-08-29
The security of a cryptographic key that is generated by communication through a noisy quantum channel relies on the ability to distill a shorter secure key sequence from a longer insecure one. For an important class of protocols, which exploit tomographically complete measurements on entangled pairs of any dimension, we show that the noise threshold for classical advantage distillation is identical with the threshold for quantum entanglement distillation. As a consequence, the two distillation procedures are equivalent: neither offers a security advantage over the other.
Individual differences reveal correlates of hidden hearing deficits.
Bharadwaj, Hari M; Masud, Salwa; Mehraei, Golbarg; Verhulst, Sarah; Shinn-Cunningham, Barbara G
2015-02-04
Clinical audiometry has long focused on determining the detection thresholds for pure tones, which depend on intact cochlear mechanics and hair cell function. Yet many listeners with normal hearing thresholds complain of communication difficulties, and the causes for such problems are not well understood. Here, we explore whether normal-hearing listeners exhibit such suprathreshold deficits, affecting the fidelity with which subcortical areas encode the temporal structure of clearly audible sound. Using an array of measures, we evaluated a cohort of young adults with thresholds in the normal range to assess both cochlear mechanical function and temporal coding of suprathreshold sounds. Listeners differed widely in both electrophysiological and behavioral measures of temporal coding fidelity. These measures correlated significantly with each other. Conversely, these differences were unrelated to the modest variation in otoacoustic emissions, cochlear tuning, or the residual differences in hearing threshold present in our cohort. Electroencephalography revealed that listeners with poor subcortical encoding had poor cortical sensitivity to changes in interaural time differences, which are critical for localizing sound sources and analyzing complex scenes. These listeners also performed poorly when asked to direct selective attention to one of two competing speech streams, a task that mimics the challenges of many everyday listening environments. Together with previous animal and computational models, our results suggest that hidden hearing deficits, likely originating at the level of the cochlear nerve, are part of "normal hearing." Copyright © 2015 the authors 0270-6474/15/352161-12$15.00/0.
Method for extracting long-equivalent wavelength interferometric information
NASA Technical Reports Server (NTRS)
Hochberg, Eric B. (Inventor)
1991-01-01
A process for extracting long-equivalent wavelength interferometric information from a two-wavelength polychromatic or achromatic interferometer. The process comprises the steps of simultaneously recording a non-linear sum of two different frequency visible light interferograms on a high resolution film and then placing the developed film in an optical train for Fourier transformation, low pass spatial filtering and inverse transformation of the film image to produce low spatial frequency fringes corresponding to a long-equivalent wavelength interferogram. The recorded non-linear sum irradiance derived from the two-wavelength interferometer is obtained by controlling the exposure so that the average interferogram irradiance is set at either the noise level threshold or the saturation level threshold of the film.
Testing a Method for Quantifying the Output of Implantable Middle Ear Hearing Devices
Rosowski, J.J.; Chien, W.; Ravicz, M.E.; Merchant, S.N.
2008-01-01
This report describes tests of a standard practice for quantifying the performance of implantable middle ear hearing devices (also known as implantable hearing aids). The standard and these tests were initiated by the Food and Drug Administration of the United States Government. The tests involved measurements on two hearing devices, one commercially available and the other home built, that were implanted into ears removed from human cadavers. The tests were conducted to investigate the utility of the practice and its outcome measures: the equivalent ear canal sound pressure transfer function that relates electrically driven middle ear velocities to the equivalent sound pressure needed to produce those velocities, and the maximum effective ear canal sound pressure. The practice calls for measurements in cadaveric ears in order to account for the varied anatomy and function of different human middle ears. PMID:17406105
78 FR 76035 - Airworthiness Directives; Maule Aerospace Technology, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-16
... precision machined step wedge made of 4340 steel (or similar steel with equivalent sound velocity) or at... unless an alternative instrument calibration procedure is used to set the sound velocity. 6. Obtain a... reflection of the thick section. If the digital display does not agree with the thickest thickness, follow...
Vertical amplitude phase structure of a low-frequency acoustic field in shallow water
NASA Astrophysics Data System (ADS)
Kuznetsov, G. N.; Lebedev, O. V.; Stepanov, A. N.
2016-11-01
We obtain in integral and analytic form the relations for calculating the amplitude and phase characteristics of an interference structure of orthogonal projections of the oscillation velocity vector in shallow water. For different frequencies and receiver depths, we numerically study the source depth dependences of the effective phase velocities of an equivalent plane wave, the orthogonal projections of the sound pressure phase gradient, and the projections of the oscillation velocity vector. We establish that at low frequencies in zones of interference maxima, independently of source depth, weakly varying effective phase velocity values are observed, which exceed the sound velocity in water by 5-12%. We show that the angles of arrival of the equivalent plane wave and the oscillation velocity vector in the general case differ; however, they virtually coincide in the zone of the interference maximum of the sound pressure under the condition that the horizontal projections of the oscillation velocity appreciably exceed the value of the vertical projection. We give recommendations on using the sound field characteristics in zones with maximum values for solving rangefinding and signal-detection problems.
Sound field separation with sound pressure and particle velocity measurements.
Fernandez-Grande, Efren; Jacobsen, Finn; Leclère, Quentin
2012-12-01
In conventional near-field acoustic holography (NAH) it is not possible to distinguish between sound from the two sides of the array, thus, it is a requirement that all the sources are confined to only one side and radiate into a free field. When this requirement cannot be fulfilled, sound field separation techniques make it possible to distinguish between outgoing and incoming waves from the two sides, and thus NAH can be applied. In this paper, a separation method based on the measurement of the particle velocity in two layers and another method based on the measurement of the pressure and the velocity in a single layer are proposed. The two methods use an equivalent source formulation with separate transfer matrices for the outgoing and incoming waves, so that the sound from the two sides of the array can be modeled independently. A weighting scheme is proposed to account for the distance between the equivalent sources and measurement surfaces and for the difference in magnitude between pressure and velocity. Experimental and numerical studies have been conducted to examine the methods. The double layer velocity method seems to be more robust to noise and flanking sound than the combined pressure-velocity method, although it requires an additional measurement surface. On the whole, the separation methods can be useful when the disturbance of the incoming field is significant. Otherwise the direct reconstruction is more accurate and straightforward.
MP3 player listening sound pressure levels among 10 to 17 year old students.
Keith, Stephen E; Michaud, David S; Feder, Katya; Haider, Ifaz; Marro, Leonora; Thompson, Emma; Marcoux, Andre M
2011-11-01
Using a manikin, equivalent free-field sound pressure level measurements were made from the portable digital audio players of 219 subjects, aged 10 to 17 years (93 males) at their typical and "worst-case" volume levels. Measurements were made in different classrooms with background sound pressure levels between 40 and 52 dBA. After correction for the transfer function of the ear, the median equivalent free field sound pressure levels and interquartile ranges (IQR) at typical and worst-case volume settings were 68 dBA (IQR = 15) and 76 dBA (IQR = 19), respectively. Self-reported mean daily use ranged from 0.014 to 12 h. When typical sound pressure levels were considered in combination with the average daily duration of use, the median noise exposure level, Lex, was 56 dBA (IQR = 18) and 3.2% of subjects were estimated to exceed the most protective occupational noise exposure level limit in Canada, i.e., 85 dBA Lex. Under worst-case listening conditions, 77.6% of the sample was estimated to listen to their device at combinations of sound pressure levels and average daily durations for which there is no known risk of permanent noise-induced hearing loss, i.e., ≤ 75 dBA Lex. Sources and magnitudes of measurement uncertainties are also discussed.
MISR Level 2 Aerosol and Land Versioning
Atmospheric Science Data Center
2017-10-11
... surfaces was changed: instead of using a surface contrast threshold, a new test is used which is based on a weighted mean equivalent reflectance threshold. A regional angular correlation screening test was added to aerosol ...
Understanding and managing experiential aspects of soundscapes at Muir woods national monument.
Pilcher, Ericka J; Newman, Peter; Manning, Robert E
2009-03-01
Research has found that human-caused noise can detract from the quality of the visitor experience in national parks and related areas. Moreover, impacts to the visitor experience can be managed by formulating indicators and standards of quality as suggested in park and outdoor recreation management frameworks, such as Visitor Experience and Resource Protection (VERP), as developed by the U.S. National Park Service. The research reported in this article supports the formulation of indicators and standards of quality for human-caused noise at Muir Woods National Monument, California. Phase I identified potential indicators of quality for the soundscape of Muir Woods. A visitor "listening exercise" was conducted, where respondents identified natural and human-caused sounds heard in the park and rated the degree to which each sound was "pleasing" or "annoying." Certain visitor-caused sounds such as groups talking were heard by most respondents and were rated as annoying, suggesting that these sounds may be a good indicator of quality. Loud groups were heard by few people but were rated as highly annoying, whereas wind and water were heard by most visitors and were rated as highly pleasing. Phase II measured standards of quality for visitor-caused noise. Visitors were presented with a series of 30-second audio clips representing increasing amounts of visitor-caused sound in the park. Respondents were asked to rate the acceptability of each audio clip on a survey. Findings suggest a threshold at which visitor-caused sound is judged to be unacceptable, and is therefore considered as noise. A parallel program of sound monitoring in the park found that current levels of visitor-caused sound sometimes violate this threshold. Study findings provide an empirical basis to help formulate noise-related indicators and standards of quality in parks and related areas.
NASA Astrophysics Data System (ADS)
Huang, Lingzhi; Xiao, Yong; Wen, Jihong; Zhang, Hao; Wen, Xisen
2018-07-01
Acoustic coatings with periodically arranged internal cavities have been successfully applied in submarines for the purpose of decoupling water from vibration of underwater structures, and thus reducing underwater sound radiation. Previous publications on decoupling acoustic coatings with cavities are mainly focused on the case of coatings with specific shaped cavities, including cylindrical and conical cavities. To explore better decoupling performance, an optimal design of acoustic coating with complex shaped cavities is attempted in this paper. An equivalent fluid model is proposed to characterize coatings with general axisymmetrical cavities. By employing the equivalent fluid model, an analytical vibroacoustic model is further developed for the prediction of sound radiation from an infinite plate covered with an equivalent fluid layer (as a replacement of original coating) and immersed in water. Numerical examples are provided to verify the equivalent fluid model. Based on a combining use of the analytical vibroacoustic model and a differential evolution algorithm, optimal designs for acoustic coatings with cavities are conducted. Numerical results demonstrate that the decoupling performance of acoustic coating can be significantly improved by employing special axisymmetrical cavities as compared to traditional cylindrical cavities.
Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S
2015-04-01
Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.
Matusiewicz, Alexis K; Carter, Anne E; Landes, Reid D; Yi, Richard
2013-11-01
Delay discounting (DD) and probability discounting (PD) refer to the reduction in the subjective value of outcomes as a function of delay and uncertainty, respectively. Elevated measures of discounting are associated with a variety of maladaptive behaviors, and confidence in the validity of these measures is imperative. The present research examined (1) the statistical equivalence of discounting measures when rewards were hypothetical or real, and (2) their 1-week reliability. While previous research has partially explored these issues using the low threshold of nonsignificant difference, the present study fully addressed this issue using the more-compelling threshold of statistical equivalence. DD and PD measures were collected from 28 healthy adults using real and hypothetical $50 rewards during each of two experimental sessions, one week apart. Analyses using area-under-the-curve measures revealed a general pattern of statistical equivalence, indicating equivalence of real/hypothetical conditions as well as 1-week reliability. Exceptions are identified and discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Detection of Sound Image Movement During Horizontal Head Rotation
Ohba, Kagesho; Iwaya, Yukio; Suzuki, Yôiti
2016-01-01
Movement detection for a virtual sound source was measured during the listener’s horizontal head rotation. Listeners were instructed to do head rotation at a given speed. A trial consisted of two intervals. During an interval, a virtual sound source was presented 60° to the right or left of the listener, who was instructed to rotate the head to face the sound image position. Then in one of a pair of intervals, the sound position was moved slightly in the middle of the rotation. Listeners were asked to judge the interval in a trial during which the sound stimuli moved. Results suggest that detection thresholds are higher when listeners do head rotation. Moreover, this effect was found to be independent of the rotation velocity. PMID:27698993
Dynamics of infant cortical auditory evoked potentials (CAEPs) for tone and speech tokens.
Cone, Barbara; Whitaker, Richard
2013-07-01
Cortical auditory evoked potentials (CAEPs) to tones and speech sounds were obtained in infants to: (1) further knowledge of auditory development above the level of the brainstem during the first year of life; (2) establish CAEP input-output functions for tonal and speech stimuli as a function of stimulus level and (3) elaborate the data-base that establishes CAEP in infants tested while awake using clinically relevant stimuli, thus providing methodology that would have translation to pediatric audiological assessment. Hypotheses concerning CAEP development were that the latency and amplitude input-output functions would reflect immaturity in encoding stimulus level. In a second experiment, infants were tested with the same stimuli used to evoke the CAEPs. Thresholds for these stimuli were determined using observer-based psychophysical techniques. The hypothesis was that the behavioral thresholds would be correlated with CAEP input-output functions because of shared cortical response areas known to be active in sound detection. 36 infants, between the ages of 4 and 12 months (mean=8 months, s.d.=1.8 months) and 9 young adults (mean age 21 years) with normal hearing were tested. First, CAEPs amplitude and latency input-output functions were obtained for 4 tone bursts and 7 speech tokens. The tone bursts stimuli were 50 ms tokens of pure tones at 0.5, 1.0, 2.0 and 4.0 kHz. The speech sound tokens, /a/, /i/, /o/, /u/, /m/, /s/, and /∫/, were created from natural speech samples and were also 50 ms in duration. CAEPs were obtained for tone burst and speech token stimuli at 10 dB level decrements in descending order from 70 dB SPL. All CAEP tests were completed while the infants were awake and engaged in quiet play. For the second experiment, observer-based psychophysical methods were used to establish perceptual threshold for the same speech sound and tone tokens. Infant CAEP component latencies were prolonged by 100-150 ms in comparison to adults. CAEP latency-intensity input output functions were steeper in infants compared to adults. CAEP amplitude growth functions with respect to stimulus SPL are adult-like at this age, particularly for the earliest component, P1-N1. Infant perceptual thresholds were elevated with respect to those found in adults. Furthermore, perceptual thresholds were higher, on average, than levels at which CAEPs could be obtained. When CAEP amplitudes were plotted with respect to perceptual threshold (dB SL), the infant CAEP amplitude growth slopes were steeper than in adults. Although CAEP latencies indicate immaturity in neural transmission at the level of the cortex, amplitude growth with respect to stimulus SPL is adult-like at this age, particularly for the earliest component, P1-N1. The latency and amplitude input-output functions may provide additional information as to how infants perceive stimulus level. The reasons for the discrepancy between electrophysiologic and perceptual threshold may be due to immaturity in perceptual temporal resolution abilities and the broad-band listening strategy employed by infants. The findings from the current study can be translated to the clinical setting. It is possible to use tonal or speech sound tokens to evoke CAEPs in an awake, passively alert infant, and thus determine whether these sounds activate the auditory cortex. This could be beneficial in the verification of hearing aid or cochlear implant benefit. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Jingxiang; Zhao, Shengdun; Ishihara, Kunihiko
2013-05-01
A novel approach is presented to study the acoustical properties of sintered bronze material, especially used to suppress the transient noise generated by the pneumatic exhaust of pneumatic friction clutch and brake (PFC/B) systems. The transient exhaust noise is impulsive and harmful due to the large sound pressure level (SPL) that has high-frequency. In this paper, the exhaust noise is related to the transient impulsive exhaust, which is described by a one-dimensional aerodynamic model combining with a pressure drop expression of the Ergun equation. A relation of flow parameters and sound source is set up. Additionally, the piston acoustic source approximation of sintered bronze silencer with cylindrical geometry is presented to predict SPL spectrum at a far-field observation point. A semi-phenomenological model is introduced to analyze the sound propagation and reduction in the sintered bronze materials assumed as an equivalent fluid with rigid frame. Experiment results under different initial cylinder pressures are shown to corroborate the validity of the proposed aerodynamic model. In addition, the calculated sound pressures according to the equivalent sound source are compared with the measured noise signals both in time-domain and frequency-domain. Influences of porosity of the sintered bronze material are also discussed.
Keefe, Douglas H; Feeney, M Patrick; Hunter, Lisa L; Fitzpatrick, Denis F
2017-01-01
Human ear-canal properties of transient acoustic stimuli are contrasted that utilize measured ear-canal pressures in conjunction with measured acoustic pressure reflectance and admittance. These data are referenced to the tip of a probe snugly inserted into the ear canal. Promising procedures to calibrate across frequency include stimuli with controlled levels of incident pressure magnitude, absorbed sound power, and forward pressure magnitude. An equivalent pressure at the eardrum is calculated from these measured data using a transmission-line model of ear-canal acoustics parameterized by acoustically estimated ear-canal area at the probe tip and length between the probe tip and eardrum. Chirp stimuli with constant incident pressure magnitude and constant absorbed sound power across frequency were generated to elicit transient-evoked otoacoustic emissions (TEOAEs), which were measured in normal-hearing adult ears from 0.7 to 8 kHz. TEOAE stimuli had similar peak-to-peak equivalent sound pressure levels across calibration conditions. Frequency-domain TEOAEs were compared using signal level, signal-to-noise ratio (SNR), coherence synchrony modulus (CSM), group delay, and group spread. Time-domain TEOAEs were compared using SNR, CSM, instantaneous frequency and instantaneous bandwidth. Stimuli with constant incident pressure magnitude or constant absorbed sound power across frequency produce generally similar TEOAEs up to 8 kHz.
Football match spectator sound exposure and effect on hearing: a pretest-post-test study.
Swanepoel, De Wet; Hall, James W
2010-03-30
To determine (i) noise exposure levels of spectators at a FIFA 2010 designated training stadium during a premier soccer league match; and (ii) changes in auditory functioning after the match. This was a one-group pretest-post-test design of football spectators attending a premier soccer league match at a designated FIFA 2010 training stadium in Gauteng, South Africa. Individual spectator noise exposure for the duration of the football match and post-match changes in hearing thresholds were measured with pure-tone audiometry, and cochlear functioning was measured with distortion product oto-acoustic emissions (DPOAEs). The average sound exposure level during the match was 100.5 LAeq (dBA), with peak intensities averaging 140.4 dB(C). A significant (p=0.005) deterioration of post-match hearing thresholds was evident at 2 000 Hz, and post-match DPOAE amplitudes were significantly reduced at 1,266, 3,163 and 5,063 Hz (p=0.011, 0.019, 0.013, respectively). Exposure levels exceeded limits of permissible average and peak sound levels. Significant changes in post-match hearing thresholds and cochlear responsiveness highlight the possible risk for noise-induced hearing loss. Public awareness and personal hearing protection should be prioritized as preventive measures.
NASA Astrophysics Data System (ADS)
Belanger, Andrea J.; Higgs, Dennis M.
2005-04-01
The round goby (Neogobius melanostomus), is an invasive species in the Great Lakes watershed. Adult round gobies show behavioral responses to conspecific vocalizations but physiological investigations have not yet been conducted to quantify their hearing abilities. We have been examining the physiological and morphological development of the auditory system in the round goby. Various frequencies (100 Hz to 800 Hz and conspecific sounds), at various intensities (120 dB to 170 dB re 1 Pa) were presented to juveniles and adults and their auditory brain-stem responses (ABR) were recorded. Round gobies only respond physiologically to tones from 100-600 Hz, with threshold varying between 145 to 155 dB re 1 Pa. The response threshold to conspecific sounds was 140 dB re 1 Pa. There was no significant difference in auditory threshold between sizes of fish for either tones or conspecific sounds. Saccular epithelia were stained using phalloidin and there was a trend towards an increase in both hair cell number and density with an increase in fish size. These results represent a first attempt to quantify auditory abilities in this invasive species. This is an important step in understanding their reproductive physiology, which could potentially aid in their population control. [Funded by NSERC.
High-frequency profile in adolescents and its relationship with the use of personal stereo devices.
Silvestre, Renata Almeida Araújo; Ribas, Ângela; Hammerschmidt, Rogério; de Lacerda, Adriana Bender Moreira
2016-01-01
To analyze and correlate the audiometric findings of high frequencies (9-16 kHz) in adolescents with their hearing habits and attitudes, in order to prevent noise-induced hearing loss. This was a descriptive cross-sectional study, which included 125 adolescents in a sample of normal-hearing students, at a state school. The subjects performed high-frequency audiometry testing and answered a self-administered questionnaire addressing information on sound habits concerning the use of personal stereo devices. The sample was divided according to the exposure characteristics (time, duration, intensity, etc.) and the results were compared with the observed thresholds, through the difference in proportions test, chi-squared, Student's t-test, and ANOVA, all at a significance level of 0.05. Average high-frequency thresholds were registered below 15 dB HL and no significant correlation was found between high frequency audiometric findings and the degree of exposure. The prevalence of harmful sound habits due to the use of personal stereo devices is high in the adolescent population, but there was no correlation between exposure to high sound pressure levels through personal stereos and the high-frequency thresholds in this population. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Caversaccio, Marco
2014-01-01
Objective. To compare hearing and speech understanding between a new, nonskin penetrating Baha system (Baha Attract) to the current Baha system using a skin-penetrating abutment. Methods. Hearing and speech understanding were measured in 16 experienced Baha users. The transmission path via the abutment was compared to a simulated Baha Attract transmission path by attaching the implantable magnet to the abutment and then by adding a sample of artificial skin and the external parts of the Baha Attract system. Four different measurements were performed: bone conduction thresholds directly through the sound processor (BC Direct), aided sound field thresholds, aided speech understanding in quiet, and aided speech understanding in noise. Results. The simulated Baha Attract transmission path introduced an attenuation starting from approximately 5 dB at 1000 Hz, increasing to 20–25 dB above 6000 Hz. However, aided sound field threshold shows smaller differences and aided speech understanding in quiet and in noise does not differ significantly between the two transmission paths. Conclusion. The Baha Attract system transmission path introduces predominately high frequency attenuation. This attenuation can be partially compensated by adequate fitting of the speech processor. No significant decrease in speech understanding in either quiet or in noise was found. PMID:25140314
ERIC Educational Resources Information Center
Goehring, Jenny L.; Hughes, Michelle L.
2017-01-01
Purpose: This study evaluated the use of telepractice for measuring cochlear implant (CI) behavioral threshold (T) levels in children using conditioned play audiometry (CPA). The goals were to determine whether (a) T levels measured via telepractice were not significantly different from those obtained in person, (b) response probability differed…
78 FR 76040 - Airworthiness Directives; Piper Aircraft, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-16
... machined step wedge made of 4340 steel (or similar steel with equivalent sound velocity) or at least three... procedure is used to set the sound velocity. 6. Obtain a step wedge or steel shims per item 3 of the... that the gate is triggered by the second backwall reflection of the thick section. If the digital...
78 FR 49221 - Airworthiness Directives; Piper Aircraft, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-13
... machined step wedge made of 4340 steel (or similar steel with equivalent sound velocity) or at least three... procedure is used to set the sound velocity. 6. Obtain a step wedge or steel shims per item 3 of the... that the gate is triggered by the second backwall reflection of the thick section. If the digital...
78 FR 3356 - Airworthiness Directives; Various Aircraft Equipped With Wing Lift Struts
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-16
... (or similar steel with equivalent sound velocity) or at least three shim samples of same material will... procedure is used to set the sound velocity. 6. Obtain a step wedge or steel shims per item 3 of the... that the gate is triggered by the second backwall reflection of the thick section. If the digital...
John, Andrew B; Kreisman, Brian M
2017-09-01
Extended high-frequency (EHF) audiometry is useful for evaluating ototoxic exposures and may relate to speech recognition, localisation and hearing aid benefit. There is a need to determine whether common clinical practice for EHF audiometry using tone and noise stimuli is reliable. We evaluated equivalence and compared test-retest (TRT) reproducibility for audiometric thresholds obtained using pure tones and narrowband noise (NBN) from 0.25 to 16 kHz. Thresholds and test-retest reproducibility for stimuli in the conventional (0.25-6 kHz) and EHF (8-16 kHz) frequency ranges were compared in a repeated-measures design. A total of 70 ears of adults with normal hearing. Thresholds obtained using NBN were significantly lower than thresholds obtained using pure tones from 0.5 to 16 kHz, but not 0.25 kHz. Good TRT reproducibility (within 2 dB) was observed for both stimuli at all frequencies. Responses at the lower limit of the presentation range for NBN centred at 14 and 16 kHz suggest unreliability for NBN as a threshold stimulus at these frequencies. Thresholds in the conventional and EHF ranges showed good test-retest reproducibility, but differed between stimulus types. Care should be taken when comparing pure-tone thresholds with NBN thresholds especially at these frequencies.
The Sound and Feel of Titrations: A Smartphone Aid for Color-Blind and Visually Impaired Students
ERIC Educational Resources Information Center
Bandyopadhyay, Subhajit; Rathod, Balraj B.
2017-01-01
An Android-based application has been developed to provide color-blind and visually impaired students a multisensory perception of color change observed in a titration. The application records and converts the color information into beep sounds and vibration pulses, which are generated by the smartphone. It uses a range threshold of hue and…
Safety of the HyperSound® Audio System in Subjects with Normal Hearing.
Mehta, Ritvik P; Mattson, Sara L; Kappus, Brian A; Seitzman, Robin L
2015-06-11
The objective of the study was to assess the safety of the HyperSound® Audio System (HSS), a novel audio system using ultrasound technology, in normal hearing subjects under normal use conditions; we considered pre-exposure and post-exposure test design. We investigated primary and secondary outcome measures: i) temporary threshold shift (TTS), defined as >10 dB shift in pure tone air conduction thresholds and/or a decrement in distortion product otoacoustic emissions (DPOAEs) >10 dB at two or more frequencies; ii) presence of new-onset otologic symptoms after exposure. Twenty adult subjects with normal hearing underwent a pre-exposure assessment (pure tone air conduction audiometry, tympanometry, DPOAEs and otologic symptoms questionnaire) followed by exposure to a 2-h movie with sound delivered through the HSS emitter followed by a post-exposure assessment. No TTS or new-onset otological symptoms were identified. HSS demonstrates excellent safety in normal hearing subjects under normal use conditions.
Safety of the HyperSound® Audio System in Subjects with Normal Hearing
Mattson, Sara L.; Kappus, Brian A.; Seitzman, Robin L.
2015-01-01
The objective of the study was to assess the safety of the HyperSound® Audio System (HSS), a novel audio system using ultrasound technology, in normal hearing subjects under normal use conditions; we considered pre-exposure and post-exposure test design. We investigated primary and secondary outcome measures: i) temporary threshold shift (TTS), defined as >10 dB shift in pure tone air conduction thresholds and/or a decrement in distortion product otoacoustic emissions (DPOAEs) >10 dB at two or more frequencies; ii) presence of new-onset otologic symptoms after exposure. Twenty adult subjects with normal hearing underwent a pre-exposure assessment (pure tone air conduction audiometry, tympanometry, DPOAEs and otologic symptoms questionnaire) followed by exposure to a 2-h movie with sound delivered through the HSS emitter followed by a post-exposure assessment. No TTS or new-onset otological symptoms were identified. HSS demonstrates excellent safety in normal hearing subjects under normal use conditions. PMID:26779330
Infrasonic and low-frequency insert earphone hearing threshold.
Kuehler, Robert; Fedtke, Thomas; Hensel, Johannes
2015-04-01
Low-frequency and infrasonic pure-tone monaural hearing threshold data down to 2.5 Hz are presented. These measurements were made by means of a newly developed insert-earphone source. The source is able to generate pure-tone sound pressure levels up to 130 dB between 2 and 250 Hz with very low harmonic distortions. Behavioral hearing thresholds were determined in the frequency range from 2.5 to 125 Hz for 18 otologically normal test persons. The median hearing thresholds are comparable to values given in the literature. They are intended for stimulus calibration in subsequent brain imaging investigations.
Noise exposure during ambulance flights and repatriation operations.
Küpper, Thomas E; Zimmer, Bernd; Conrad, Gerson; Jansing, Paul; Hardt, Aline
2010-01-01
Although ambulance flights are routine work and thousands of employees work in repatriation organizations, there is no data on noise exposure which may be used for preventive advice. We investigated the noise exposure of crews working in ambulance flight organizations for international patient repatriation to get the data for specific guidelines concerning noise protection. Noise levels inside Learjet 35A, the aircraft type which is most often used for repatriation operations, were collected from locations where flight crews typically spend their time. A sound level meter class 1 meeting the DIN IEC 651 requirements was used for noise measurements, but several factors during the real flight situations caused a measurement error of ~3%. Therefore, the results fulfill the specifications for class 2. The data was collected during several real repatriation operations and was combined with the flight data (hours per day) regarding the personnel to evaluate the occupationally encountered equivalent noise level according to DIN 45645-2. The measured noise levels were safely just below the 85 dB(A) threshold and should not induce permanent threshold shifts, provided that additional high noise exposure by non-occupational or private activities was avoided. As the levels of the noise produced by the engines outside the cabin are significantly above the 85 dB(A) threshold, the doors of the aircraft must be kept closed while the engines are running, and any activity performed outside the aircraft - or with the doors opened while the engines are running - must be done with adequate noise protection. The new EU noise directive (2003/10/EG) states that protective equipment must be made available to the aircrew to protect their hearing, though its use is not mandatory.
Sound Exposure of Healthcare Professionals Working with a University Marching Band.
Russell, Jeffrey A; Yamaguchi, Moegi
2018-01-01
Music-induced hearing disorders are known to result from exposure to excessive levels of music of different genres. Marching band music, with its heavy emphasis on brass and percussion, is one type that is a likely contributor to music-induced hearing disorders, although specific data on sound pressure levels of marching bands have not been widely studied. Furthermore, if marching band music does lead to music-induced hearing disorders, the musicians may not be the only individuals at risk. Support personnel such as directors, equipment managers, and performing arts healthcare providers may also be exposed to potentially damaging sound pressures. Thus, we sought to explore to what degree healthcare providers receive sound dosages above recommended limits during their work with a marching band. The purpose of this study was to determine the sound exposure of healthcare professionals (specifically, athletic trainers [ATs]) who provide on-site care to a large, well-known university marching band. We hypothesized that sound pressure levels to which these individuals were exposed would exceed the National Institute for Occupational Safety and Health (NIOSH) daily percentage allowance. Descriptive observational study. Eight ATs working with a well-known American university marching band volunteered to wear noise dosimeters. During the marching band season, ATs wore an Etymotic ER-200D dosimeter whenever working with the band at outdoor rehearsals, indoor field house rehearsals, and outdoor performances. The dosimeters recorded dose percent exposure, equivalent continuous sound levels in A-weighted decibels, and duration of exposure. For comparison, a dosimeter also was worn by an AT working in the university's performing arts medicine clinic. Participants did not alter their typical duties during any data collection sessions. Sound data were collected with the dosimeters set at the NIOSH standards of 85 dBA threshold and 3 dBA exchange rate; the NIOSH 100% daily dose is an exposure to 85 dBA over 8 h. Dose data for each session were converted to a standardized dose intensity by dividing the dose percentage by the duration of the exposure and setting the NIOSH standard as a factor of 1.0. This allowed convenient relative comparisons of dose percentages of vastly different exposure durations. Analysis of variance examined relationships of noise exposures among the venues; post hoc testing was used to assess pairwise differences. As hypothesized, ATs were exposed to high sound pressure levels and dose percentages greatly exceeding those recommended by NIOSH. Higher sound levels were recorded in performance venues compared with rehearsal venues. In addition to the band music, crowd noise and public address systems contribute to high sound levels at performances. Our results suggest that healthcare providers working with marching bands are exposed to dangerous levels of sound during performances. This is especially true at venues such as football stadiums, where crowd noise and public address systems add to sound pressure. A hearing conservation program, including protection, should be required for all healthcare staff who work with marching bands. Moreover, our results should inform hearing conservation practices for marching musicians, directors, and support personnel. American Academy of Audiology
Johnson, Jeffrey S.; Yin, Pingbo; O'Connor, Kevin N.
2012-01-01
Amplitude modulation (AM) is a common feature of natural sounds, and its detection is biologically important. Even though most sounds are not fully modulated, the majority of physiological studies have focused on fully modulated (100% modulation depth) sounds. We presented AM noise at a range of modulation depths to awake macaque monkeys while recording from neurons in primary auditory cortex (A1). The ability of neurons to detect partial AM with rate and temporal codes was assessed with signal detection methods. On average, single-cell synchrony was as or more sensitive than spike count in modulation detection. Cells are less sensitive to modulation depth if tested away from their best modulation frequency, particularly for temporal measures. Mean neural modulation detection thresholds in A1 are not as sensitive as behavioral thresholds, but with phase locking the most sensitive neurons are more sensitive, suggesting that for temporal measures the lower-envelope principle cannot account for thresholds. Three methods of preanalysis pooling of spike trains (multiunit, similar to convergence from a cortical column; within cell, similar to convergence of cells with matched response properties; across cell, similar to indiscriminate convergence of cells) all result in an increase in neural sensitivity to modulation depth for both temporal and rate codes. For the across-cell method, pooling of a few dozen cells can result in detection thresholds that approximate those of the behaving animal. With synchrony measures, indiscriminate pooling results in sensitive detection of modulation frequencies between 20 and 60 Hz, suggesting that differences in AM response phase are minor in A1. PMID:22422997
Effects of Airgun Sounds on Bowhead Whale Calling Rates: Evidence for Two Behavioral Thresholds
Blackwell, Susanna B.; Nations, Christopher S.; McDonald, Trent L.; Thode, Aaron M.; Mathias, Delphine; Kim, Katherine H.; Greene, Charles R.; Macrander, A. Michael
2015-01-01
In proximity to seismic operations, bowhead whales (Balaena mysticetus) decrease their calling rates. Here, we investigate the transition from normal calling behavior to decreased calling and identify two threshold levels of received sound from airgun pulses at which calling behavior changes. Data were collected in August–October 2007–2010, during the westward autumn migration in the Alaskan Beaufort Sea. Up to 40 directional acoustic recorders (DASARs) were deployed at five sites offshore of the Alaskan North Slope. Using triangulation, whale calls localized within 2 km of each DASAR were identified and tallied every 10 minutes each season, so that the detected call rate could be interpreted as the actual call production rate. Moreover, airgun pulses were identified on each DASAR, analyzed, and a cumulative sound exposure level was computed for each 10-min period each season (CSEL10-min). A Poisson regression model was used to examine the relationship between the received CSEL10-min from airguns and the number of detected bowhead calls. Calling rates increased as soon as airgun pulses were detectable, compared to calling rates in the absence of airgun pulses. After the initial increase, calling rates leveled off at a received CSEL10-min of ~94 dB re 1 μPa2-s (the lower threshold). In contrast, once CSEL10-min exceeded ~127 dB re 1 μPa2-s (the upper threshold), whale calling rates began decreasing, and when CSEL10-min values were above ~160 dB re 1 μPa2-s, the whales were virtually silent. PMID:26039218
Effects of airgun sounds on bowhead whale calling rates: evidence for two behavioral thresholds.
Blackwell, Susanna B; Nations, Christopher S; McDonald, Trent L; Thode, Aaron M; Mathias, Delphine; Kim, Katherine H; Greene, Charles R; Macrander, A Michael
2015-01-01
In proximity to seismic operations, bowhead whales (Balaena mysticetus) decrease their calling rates. Here, we investigate the transition from normal calling behavior to decreased calling and identify two threshold levels of received sound from airgun pulses at which calling behavior changes. Data were collected in August-October 2007-2010, during the westward autumn migration in the Alaskan Beaufort Sea. Up to 40 directional acoustic recorders (DASARs) were deployed at five sites offshore of the Alaskan North Slope. Using triangulation, whale calls localized within 2 km of each DASAR were identified and tallied every 10 minutes each season, so that the detected call rate could be interpreted as the actual call production rate. Moreover, airgun pulses were identified on each DASAR, analyzed, and a cumulative sound exposure level was computed for each 10-min period each season (CSEL10-min). A Poisson regression model was used to examine the relationship between the received CSEL10-min from airguns and the number of detected bowhead calls. Calling rates increased as soon as airgun pulses were detectable, compared to calling rates in the absence of airgun pulses. After the initial increase, calling rates leveled off at a received CSEL10-min of ~94 dB re 1 μPa2-s (the lower threshold). In contrast, once CSEL10-min exceeded ~127 dB re 1 μPa2-s (the upper threshold), whale calling rates began decreasing, and when CSEL10-min values were above ~160 dB re 1 μPa2-s, the whales were virtually silent.
Aural Acoustic Stapedius-Muscle Reflex Threshold Procedures to Test Human Infants and Adults.
Keefe, Douglas H; Feeney, M Patrick; Hunter, Lisa L; Fitzpatrick, Denis F
2017-02-01
Power-based procedures are described to measure acoustic stapedius-muscle reflex threshold and supra-threshold responses in human adult and infant ears at frequencies from 0.2 to 8 kHz. The stimulus set included five clicks in which four pulsed activators were placed between each pair of clicks, with each stimulus set separated from the next by 0.79 s to allow for reflex decay. Each click response was used to detect the presence of reflex effects across frequency that were elicited by a pulsed broadband-noise or tonal activator in the ipsilateral or contralateral test ear. Acoustic reflex shifts were quantified in terms of the difference in absorbed sound power between the initial baseline click and the later four clicks in each set. Acoustic reflex shifts were measured over a 40-dB range of pulsed activators, and the acoustic reflex threshold was objectively calculated using a maximum 10 likelihood procedure. To illustrate the principles underlying these new reflex tests, reflex shifts in absorbed sound power and absorbance are presented for data acquired in an adult ear with normal hearing and in two infant ears in the initial and follow-up newborn hearing screening exams, one with normal hearing and the other with a conductive hearing loss. The use of absorbed sound power was helpful in classifying an acoustic reflex shift as present or absent. The resulting reflex tests are in use in a large study of wideband clinical diagnosis and monitoring of middle-ear and cochlear function in infant and adult ears.
Sensitivity to Envelope Interaural Time Differences at High Modulation Rates
Bleeck, Stefan; McAlpine, David
2015-01-01
Sensitivity to interaural time differences (ITDs) conveyed in the temporal fine structure of low-frequency tones and the modulated envelopes of high-frequency sounds are considered comparable, particularly for envelopes shaped to transmit similar fidelity of temporal information normally present for low-frequency sounds. Nevertheless, discrimination performance for envelope modulation rates above a few hundred Hertz is reported to be poor—to the point of discrimination thresholds being unattainable—compared with the much higher (>1,000 Hz) limit for low-frequency ITD sensitivity, suggesting the presence of a low-pass filter in the envelope domain. Further, performance for identical modulation rates appears to decline with increasing carrier frequency, supporting the view that the low-pass characteristics observed for envelope ITD processing is carrier-frequency dependent. Here, we assessed listeners’ sensitivity to ITDs conveyed in pure tones and in the modulated envelopes of high-frequency tones. ITD discrimination for the modulated high-frequency tones was measured as a function of both modulation rate and carrier frequency. Some well-trained listeners appear able to discriminate ITDs extremely well, even at modulation rates well beyond 500 Hz, for 4-kHz carriers. For one listener, thresholds were even obtained for a modulation rate of 800 Hz. The highest modulation rate for which thresholds could be obtained declined with increasing carrier frequency for all listeners. At 10 kHz, the highest modulation rate at which thresholds could be obtained was 600 Hz. The upper limit of sensitivity to ITDs conveyed in the envelope of high-frequency modulated sounds appears to be higher than previously considered. PMID:26721926
Weichenberger, Markus; Bauer, Martin; Kühler, Robert; Hensel, Johannes; Forlim, Caroline Garcia; Ihlenfeld, Albrecht; Ittermann, Bernd; Gallinat, Jürgen; Koch, Christian; Kühn, Simone
2017-01-01
In the present study, the brain's response towards near- and supra-threshold infrasound (IS) stimulation (sound frequency < 20 Hz) was investigated under resting-state fMRI conditions. The study involved two consecutive sessions. In the first session, 14 healthy participants underwent a hearing threshold-as well as a categorical loudness scaling measurement in which the individual loudness perception for IS was assessed across different sound pressure levels (SPL). In the second session, these participants underwent three resting-state acquisitions, one without auditory stimulation (no-tone), one with a monaurally presented 12-Hz IS tone (near-threshold) and one with a similar tone above the individual hearing threshold corresponding to a 'medium loud' hearing sensation (supra-threshold). Data analysis mainly focused on local connectivity measures by means of regional homogeneity (ReHo), but also involved independent component analysis (ICA) to investigate inter-regional connectivity. ReHo analysis revealed significantly higher local connectivity in right superior temporal gyrus (STG) adjacent to primary auditory cortex, in anterior cingulate cortex (ACC) and, when allowing smaller cluster sizes, also in the right amygdala (rAmyg) during the near-threshold, compared to both the supra-threshold and the no-tone condition. Additional independent component analysis (ICA) revealed large-scale changes of functional connectivity, reflected in a stronger activation of the right amygdala (rAmyg) in the opposite contrast (no-tone > near-threshold) as well as the right superior frontal gyrus (rSFG) during the near-threshold condition. In summary, this study is the first to demonstrate that infrasound near the hearing threshold may induce changes of neural activity across several brain regions, some of which are known to be involved in auditory processing, while others are regarded as keyplayers in emotional and autonomic control. These findings thus allow us to speculate on how continuous exposure to (sub-)liminal IS could exert a pathogenic influence on the organism, yet further (especially longitudinal) studies are required in order to substantialize these findings.
Temporary threshold shift after impulse-noise during video game play: laboratory data.
Spankovich, C; Griffiths, S K; Lobariñas, E; Morgenstein, K E; de la Calle, S; Ledon, V; Guercio, D; Le Prell, C G
2014-03-01
Prevention of temporary threshold shift (TTS) after laboratory-based exposure to pure-tones, broadband noise, and narrowband noise signals has been achieved, but prevention of TTS under these experimental conditions may not accurately reflect protection against hearing loss following impulse noise. This study used a controlled laboratory-based TTS paradigm that incorporated impulsive stimuli into the exposure protocol; development of this model could provide a novel platform for assessing proposed therapeutics. Participants played a video game that delivered gunfire-like sound through headphones as part of a target practice game. Effects were measured using audiometric threshold evaluations and distortion product otoacoustic emissions (DPOAEs). The sound level and number of impulses presented were sequentially increased throughout the study. Participants were normal-hearing students at the University of Florida who provided written informed consent prior to participation. TTS was not reliably induced by any of the exposure conditions assessed here. However, there was significant individual variability, and a subset of subjects showed TTS under some exposure conditions. A subset of participants demonstrated reliable threshold shifts under some conditions. Additional experiments are needed to better understand and optimize stimulus parameters that influence TTS after simulated impulse noise.
Temporary threshold shift after impulse-noise during video game play: Laboratory data
Spankovich, C.; Griffiths, S. K.; Lobariñas, E.; Morgenstein, K.E.; de la Calle, S.; Ledon, V.; Guercio, D.; Le Prell, C.G.
2015-01-01
Objective Prevention of temporary threshold shift (TTS) after laboratory-based exposure to pure-tones, broadband noise, and narrow band noise signals has been achieved, but prevention of TTS under these experimental conditions may not accurately reflect protection against hearing loss following impulse noise. This study used a controlled laboratory-based TTS paradigm that incorporated impulsive stimuli into the exposure protocol; development of this model could provide a novel platform for assessing proposed therapeutics. Design Participants played a video game that delivered gunfire-like sound through headphones as part of a target practice game. Effects were measured using audiometric threshold evaluations and distortion product otoacoustic emissions (DPOAEs). The sound level and number of impulses presented were sequentially increased throughout the study. Study sample Participants were normal-hearing students at the University of Florida who provided written informed consent prior to participation. Results TTS was not reliably induced by any of the exposure conditions assessed here. However, there was significant individual variability, and a subset of subjects showed TTS under some exposure conditions. Conclusions A subset of participants demonstrated reliable threshold shifts under some conditions. Additional experiments are needed to better understand and optimize stimulus parameters that influence TTS after simulated impulse noise. PMID:24564694
Result on speech perception after conversion from Spectra® to Freedom®.
Magalhães, Ana Tereza de Matos; Goffi-Gomez, Maria Valéria Schmidt; Hoshino, Ana Cristina; Tsuji, Robinson Koji; Bento, Ricardo Ferreira; Brito, Rubens
2012-04-01
New technology in the Freedom® speech processor for cochlear implants was developed to improve how incoming acoustic sound is processed; this applies not only for new users, but also for previous generations of cochlear implants. To identify the contribution of this technology-- the Nucleus 22®--on speech perception tests in silence and in noise, and on audiometric thresholds. A cross-sectional cohort study was undertaken. Seventeen patients were selected. The last map based on the Spectra® was revised and optimized before starting the tests. Troubleshooting was used to identify malfunction. To identify the contribution of the Freedom® technology for the Nucleus22®, auditory thresholds and speech perception tests were performed in free field in sound-proof booths. Recorded monosyllables and sentences in silence and in noise (SNR = 0dB) were presented at 60 dBSPL. The nonparametric Wilcoxon test for paired data was used to compare groups. Freedom® applied for the Nucleus22® showed a statistically significant difference in all speech perception tests and audiometric thresholds. The Freedom® technology improved the performance of speech perception and audiometric thresholds of patients with Nucleus 22®.
78 FR 73997 - Airworthiness Directives; Various Aircraft Equipped with Wing Lift Struts
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-10
... wedge made of 4340 steel (or similar steel with equivalent sound velocity) or at least three shim... procedure is used to set the sound velocity. 6. Obtain a step wedge or steel shims per item 3 of the... width so that the gate is triggered by the second backwall reflection of the thick section. If the...
Caporali, Priscila Faissola; Caporali, Sueli Aparecida; Bucuvic, Érika Cristina; Vieira, Sheila de Souza; Santos, Zeila Maria; Chiari, Brasília Maria
2016-01-01
Translation and cross-cultural adaptation of the instrument Hearing Implant Sound Quality Index (HISQUI19), and characterization of the target population and auditory performance in Cochlear Implant (CI) users through the application of a synthesis version of this tool. Evaluations of conceptual, item, semantic and operational equivalences were performed. The synthesis version was applied as a pre-test to 33 individuals, whose final results characterized the final sample and performance of the questionnaire. The results were analyzed statistically. The final translation (FT) was back-translated and compared with the original version, revealing a minimum difference between items. The changes observed between the FT and the synthesis version were characterized by the application of simplified vocabulary used on a daily basis. For the pre-test, the average score of the interviewees was 90.2, and a high level of reliability was achieved (0.83). The translation and cross-cultural adaptation of the HISQUI19 questionnaire showed suitability for conceptual, item, semantic and operational equivalences. For the sample characterization, the sound quality was classified as good with better performance for the categories of location and distinction of sound/voices.
Simplified method to solve sound transmission through structures lined with elastic porous material.
Lee, J H; Kim, J
2001-11-01
An approximate analysis method is developed to calculate sound transmission through structures lined with porous material. Because the porous material has both the solid phase and fluid phase, three wave components exist in the material, which makes the related analysis very complicated. The main idea in developing the approximate method is very simple: modeling the porous material using only the strongest of the three waves, which in effect idealizes the material as an equivalent fluid. The analysis procedure has to be conducted in two steps. In the first step, sound transmission through a flat double panel with a porous liner of infinite extents, which has the same cross sectional construction as the actual structure, is solved based on the full theory and the strongest wave component is identified. In the second step sound transmission through the actual structure is solved modeling the porous material as an equivalent fluid while using the actual geometry of the structure. The development and validation of the method are discussed in detail. As an application example, the transmission loss through double walled cylindrical shells with a porous core is calculated utilizing the simplified method.
Hearing and Underwater Noise Exposure
1985-08-27
Ordnance Laboratory, White Oak, Silver Springs, Md. Corso, J. F. (1963) Bone-conduction thresholds for sonic and ultrasonic frequencies. J. Acoust...Soc. Am. 35, 1738-1743. Corso, J. F., & Levine, M. (1965a) Sonic and Ultrasonic equal loudness contours. J. Exp. Psychol. 70, 412-416. Corso, J...KEY WORDS (Continue on reverse aide II neceaaary and identity by block number) Hearing, Deafness, Sonar, Noise, Sound, Ultrasound, Infra -sound
The article deals first with the theoretical foundations of underwater hearing, and the effects of the acoustical characteristics of water on hearing...lead to the conclusion that, in water , man can locate the direction of sound at low and at very high tonal frequencies of the audio range, but this ability is probably vanishing in the middle range of frequencies. (Author)
Kharlamov, Viktor; Campbell, Kenneth; Kazanina, Nina
2011-11-01
Speech sounds are not always perceived in accordance with their acoustic-phonetic content. For example, an early and automatic process of perceptual repair, which ensures conformity of speech inputs to the listener's native language phonology, applies to individual input segments that do not exist in the native inventory or to sound sequences that are illicit according to the native phonotactic restrictions on sound co-occurrences. The present study with Russian and Canadian English speakers shows that listeners may perceive phonetically distinct and licit sound sequences as equivalent when the native language system provides robust evidence for mapping multiple phonetic forms onto a single phonological representation. In Russian, due to an optional but productive t-deletion process that affects /stn/ clusters, the surface forms [sn] and [stn] may be phonologically equivalent and map to a single phonological form /stn/. In contrast, [sn] and [stn] clusters are usually phonologically distinct in (Canadian) English. Behavioral data from identification and discrimination tasks indicated that [sn] and [stn] clusters were more confusable for Russian than for English speakers. The EEG experiment employed an oddball paradigm with nonwords [asna] and [astna] used as the standard and deviant stimuli. A reliable mismatch negativity response was elicited approximately 100 msec postchange in the English group but not in the Russian group. These findings point to a perceptual repair mechanism that is engaged automatically at a prelexical level to ensure immediate encoding of speech inputs in phonological terms, which in turn enables efficient access to the meaning of a spoken utterance.
Four odontocete species change hearing levels when warned of impending loud sound.
Nachtigall, Paul E; Supin, Alexander Ya; Pacini, Aude F; Kastelein, Ronald A
2018-03-01
Hearing sensitivity change was investigated when a warning sound preceded a loud sound in the false killer whale (Pseudorca crassidens), the bottlenose dolphin (Tursiops truncatus), the beluga whale (Delphinaperus leucas) and the harbor porpoise (Phocoena phocoena). Hearing sensitivity was measured using pip-train test stimuli and auditory evoked potential recording. When the test/warning stimuli preceded a loud sound, hearing thresholds before the loud sound increased relative to the baseline by 13 to 17 dB. Experiments with multiple frequencies of exposure and shift provided evidence of different amounts of hearing change depending on frequency, indicating that the hearing sensation level changes were not likely due to a simple stapedial reflex. © 2017 International Society of Zoological Sciences, Institute of Zoology/Chinese Academy of Sciences and John Wiley & Sons Australia, Ltd.
Assessing the Effectiveness of Ramp-Up During Sonar Operations Using Exposure Models.
von Benda-Beckmann, Alexander M; Wensveen, Paul J; Kvadsheim, Petter H; Lam, Frans-Peter A; Miller, Patrick J O; Tyack, Peter L; Ainslie, Michael A
2016-01-01
Ramp-up procedures are used to mitigate the impact of sound on marine mammals. Sound exposure models combined with observations of marine mammals responding to sound can be used to assess the effectiveness of ramp-up procedures. We found that ramp-up procedures before full-level sonar operations can reduce the risk of hearing threshold shifts with marine mammals, but their effectiveness depends strongly on the responsiveness of the animals. In this paper, we investigated the effect of sonar parameters (source level, pulse-repetition time, ship speed) on sound exposure by using a simple analytical model and highlight the mechanisms that limit the effectiveness of ramp-up procedures.
Costa, Fabrizio; Cramer, Grant; Finnegan, E Jean
2017-11-10
The inclusive threshold policy for publication in BMC journals including BMC Plant Biology means that editorial decisions are largely based on the soundness of the research presented rather than the novelty or potential impact of the work. Here we discuss what is required to ensure that research meets the requirement of scientific soundness. BMC Plant Biology and the other BCM-series journals ( https://www.biomedcentral.com/p/the-bmc-series-journals ) differ in policy from many other journals as they aim to provide a home for all publishable research. The inclusive threshold policy for publication means that editorial decisions are largely based on the soundness of the research presented rather than the novelty or potential impact of the work. The emphasis on scientific soundness ( http://blogs.biomedcentral.com/bmcseriesblog/2016/12/05/vital-importance-inclusive/ ) rather than novelty or impact is important because it means that manuscripts that may be judged to be of low impact due to the nature of the study as well as those reporting negative results or that largely replicate earlier studies, all of which can be difficult to publish elsewhere, are available to the research community. Here we discuss the importance of the soundness of research and provide some basic guidelines to assist authors to determine whether their research is appropriate for submission to BMC Plant Biology.Prior to a research article being sent out for review, the handling editor will first determine whether the research presented is scientifically valid. To be valid the research must address a question of biological significance using suitable methods and analyses, and must follow community-agreed standards relevant to the research field.
NASA Astrophysics Data System (ADS)
Ovsiannikov, Mikhail; Ovsiannikov, Sergei
2017-01-01
The paper presents the combined approach to noise mapping and visualizing of industrial facilities sound pollution using forward ray tracing method and thin-plate spline interpolation. It is suggested to cauterize industrial area in separate zones with similar sound levels. Equivalent local source is defined for range computation of sanitary zones based on ray tracing algorithm. Computation of sound pressure levels within clustered zones are based on two-dimension spline interpolation of measured data on perimeter and inside the zone.
Keefe, Douglas H.; Feeney, M. Patrick; Hunter, Lisa L.; Fitzpatrick, Denis F.
2017-01-01
Human ear-canal properties of transient acoustic stimuli are contrasted that utilize measured ear-canal pressures in conjunction with measured acoustic pressure reflectance and admittance. These data are referenced to the tip of a probe snugly inserted into the ear canal. Promising procedures to calibrate across frequency include stimuli with controlled levels of incident pressure magnitude, absorbed sound power, and forward pressure magnitude. An equivalent pressure at the eardrum is calculated from these measured data using a transmission-line model of ear-canal acoustics parameterized by acoustically estimated ear-canal area at the probe tip and length between the probe tip and eardrum. Chirp stimuli with constant incident pressure magnitude and constant absorbed sound power across frequency were generated to elicit transient-evoked otoacoustic emissions (TEOAEs), which were measured in normal-hearing adult ears from 0.7 to 8 kHz. TEOAE stimuli had similar peak-to-peak equivalent sound pressure levels across calibration conditions. Frequency-domain TEOAEs were compared using signal level, signal-to-noise ratio (SNR), coherence synchrony modulus (CSM), group delay, and group spread. Time-domain TEOAEs were compared using SNR, CSM, instantaneous frequency and instantaneous bandwidth. Stimuli with constant incident pressure magnitude or constant absorbed sound power across frequency produce generally similar TEOAEs up to 8 kHz. PMID:28147608
Evaluation of auditory functions for Royal Canadian Mounted Police officers.
Vaillancourt, Véronique; Laroche, Chantal; Giguère, Christian; Beaulieu, Marc-André; Legault, Jean-Pierre
2011-06-01
Auditory fitness for duty (AFFD) testing is an important element in an assessment of workers' ability to perform job tasks safely and effectively. Functional hearing is particularly critical to job performance in law enforcement. Most often, assessment is based on pure-tone detection thresholds; however, its validity can be questioned and challenged in court. In an attempt to move beyond the pure-tone audiogram, some organizations like the Royal Canadian Mounted Police (RCMP) are incorporating additional testing to supplement audiometric data in their AFFD protocols, such as measurements of speech recognition in quiet and/or in noise, and sound localization. This article reports on the assessment of RCMP officers wearing hearing aids in speech recognition and sound localization tasks. The purpose was to quantify individual performance in different domains of hearing identified as necessary components of fitness for duty, and to document the type of hearing aids prescribed in the field and their benefit for functional hearing. The data are to help RCMP in making more informed decisions regarding AFFD in officers wearing hearing aids. The proposed new AFFD protocol included unaided and aided measures of speech recognition in quiet and in noise using the Hearing in Noise Test (HINT) and sound localization in the left/right (L/R) and front/back (F/B) horizontal planes. Sixty-four officers were identified and selected by the RCMP to take part in this study on the basis of hearing thresholds exceeding current audiometrically based criteria. This article reports the results of 57 officers wearing hearing aids. Based on individual results, 49% of officers were reclassified from nonoperational status to operational with limitations on fine hearing duties, given their unaided and/or aided performance. Group data revealed that hearing aids (1) improved speech recognition thresholds on the HINT, the effects being most prominent in Quiet and in conditions of spatial separation between target and noise (Noise Right and Noise Left) and least considerable in Noise Front; (2) neither significantly improved nor impeded L/R localization; and (3) substantially increased F/B errors in localization in a number of cases. Additional analyses also pointed to the poor ability of threshold data to predict functional abilities for speech in noise (r² = 0.26 to 0.33) and sound localization (r² = 0.03 to 0.28). Only speech in quiet (r² = 0.68 to 0.85) is predicted adequately from threshold data. Combined with previous findings, results indicate that the use of hearing aids can considerably affect F/B localization abilities in a number of individuals. Moreover, speech understanding in noise and sound localization abilities were poorly predicted from pure-tone thresholds, demonstrating the need to specifically test these abilities, both unaided and aided, when assessing AFFD. Finally, further work is needed to develop empirically based hearing criteria for the RCMP and identify best practices in hearing aid fittings for optimal functional hearing abilities. American Academy of Audiology.
Cognitive abilities relate to self-reported hearing disability.
Zekveld, Adriana A; George, Erwin L J; Houtgast, Tammo; Kramer, Sophia E
2013-10-01
In this explorative study, the authors investigated the relationship between auditory and cognitive abilities and self-reported hearing disability. Thirty-two adults with mild to moderate hearing loss completed the Amsterdam Inventory for Auditory Disability and Handicap (AIADH; Kramer, Kapteyn, Festen, & Tobi, 1996) and performed the Text Reception Threshold (TRT; Zekveld, George, Kramer, Goverts, & Houtgast, 2007) test as well as tests of spatial working memory (SWM) and visual sustained attention. Regression analyses examined the predictive value of age, hearing thresholds (pure-tone averages [PTAs]), speech perception in noise (speech reception thresholds in noise [SRTNs]), and the cognitive tests for the 5 AIADH factors. Besides the variance explained by age, PTA, and SRTN, cognitive abilities were related to each hearing factor. The reported difficulties with sound detection and speech perception in quiet were less severe for participants with higher age, lower PTAs, and better TRTs. Fewer sound localization and speech perception in noise problems were reported by participants with better SRTNs and smaller SWM. Fewer sound discrimination difficulties were reported by subjects with better SRTNs and TRTs and smaller SWM. The results suggest a general role of the ability to read partly masked text in subjective hearing. Large working memory was associated with more reported hearing difficulties. This study shows that besides auditory variables and age, cognitive abilities are related to self-reported hearing disability.
Estimating economic thresholds for pest control: an alternative procedure.
Ramirez, O A; Saunders, J L
1999-04-01
An alternative methodology to determine profit maximizing economic thresholds is developed and illustrated. An optimization problem based on the main biological and economic relations involved in determining a profit maximizing economic threshold is first advanced. From it, a more manageable model of 2 nonsimultaneous reduced-from equations is derived, which represents a simpler but conceptually and statistically sound alternative. The model recognizes that yields and pest control costs are a function of the economic threshold used. Higher (less strict) economic thresholds can result in lower yields and, therefore, a lower gross income from the sale of the product, but could also be less costly to maintain. The highest possible profits will be obtained by using the economic threshold that results in a maximum difference between gross income and pest control cost functions.
The effect of static force on round window stimulation with the direct acoustic cochlea stimulator.
Maier, Hannes; Salcher, Rolf; Schwab, Burkard; Lenarz, Thomas
2013-07-01
The Direct Acoustic Cochlea Stimulator Partial Implant (DACS PI, Phonak Acoustic Implants SA, Switzerland) is intended to stimulate the cochlea by a conventional stapedotomy piston that is crimped onto the DACS PI artificial incus. An alternative approach to the round window (RW) is successfully done with other devices, having the advantage of being also independent of the existence of middle ear structure (e.g. ossicles). Here the possibility of stimulating the RW with the DACS actuator is investigated including the impact of static force on sound transmission to the cochlea. The maximum equivalent sound pressure output with RW stimulation was determined experimentally in fresh human temporal bones. Experiments were performed in analogy to the ASTM standard (F2504.24930-1) method for the output determination of implantable middle ear hearing devices (IMEHDs) in human cadaveric temporal bones (TBs). ASTM compliant temporal bones were stimulated with a prosthesis having a spherical tip (∅0.5 mm) attached to the actuator. The stimulation was performed perpendicular to the round window membrane (RWM) at varying position relative to the RW and the resulting static force on the RW membrane was determined. At each position the displacement output of the DACS PI actuator and the stapes footplate (SFP) vibration in response to actuator stimulation was measured with a Laser Doppler Velocimeter (LDV). By comparison of the achieved output at the stapes footplate in response to sound and transducer stimulation the equivalent sound pressure level at the tympanic membrane at 1Vrms input voltage was calculated assuming that the SFP displacement in both conditions is a measure of perceived loudness, as it is done in the ASTM standard. Ten TB preparations within the acceptance range of the ASTM standard were used for analysis. The actuator driven stapes footplate displacement amplitude as well as the resulting equivalent sound pressure level was highly dependent on the static force applied to the RW. The sound transfer efficiency from the RW to the stapes footplate increased monotonically with increasing static load. At a moderate static force load (approx. 3.9 mN) the obtained average sound equivalent sound pressure level was 102-120 eq. dB SPL @ nominally 1Vrms input for frequencies ≤4 kHz. At higher frequencies (6-10 kHz) the achieved output dropped to ∼90 dB SPL. This output was obtained at loading conditions compatible with the actuator safe operating range, although it was possible to increase the output further by increasing the static force load. Our results demonstrate for a first time that static force applied to the RW is crucial for sound transmission efficiency. Further we could show that RW stimulation with the DACS PI actuator is possible having a maximum output that is sufficient to treat moderate and pronounced sensorineural hearing losses (SNHL). This article is part of a Special Issue entitled "MEMRO 2012". Copyright © 2013 Elsevier B.V. All rights reserved.
Modal sound transmission loss of a single leaf panel: Effects of inter-modal coupling.
Wang, Chong
2015-06-01
Sound transmission through a single leaf panel has mostly been discussed and explained by using the approaching wave concept, from which the well-known mass law can be derived. In this paper, the modal behavior in sound transmission coefficients is explored, and it is shown that the mutual modal radiation impedances in modal sound transmission coefficients may not be ignored even for a panel immersed in a light fluid. By introducing the equivalent modal impedance which incorporates the inter-modal coupling effect, an analytical expression for the modal sound transmission coefficient is derived, and the overall sound transmission coefficient is simply a modal superposition of modal sound transmission coefficients. A good correlation is obtained between analytical calculation and boundary element method. In addition, it is found that inter-modal coupling has noticeable effects in modal sound transmission coefficients in the subsonic region but may be ignored as modes become supersonic. It is also shown that the well-known mass law performance is attributed to all the supersonic modes.
Neves, A A; Silva, E J; Roter, J M; Belladona, F G; Alves, H D; Lopes, R T; Paciornik, S; De-Deus, G A
2015-11-01
To propose an automated image processing routine based on free software to quantify root canal preparation outcomes in pairs of sound and instrumented roots after micro-CT scanning procedures. Seven mesial roots of human mandibular molars with different canal configuration systems were studied: (i) Vertucci's type 1, (ii) Vertucci's type 2, (iii) two individual canals, (iv) Vertucci's type 6, canals (v) with and (vi) without debris, and (vii) canal with visible pulp calcification. All teeth were instrumented with the BioRaCe system and scanned in a Skyscan 1173 micro-CT before and after canal preparation. After reconstruction, the instrumented stack of images (IS) was registered against the preoperative sound stack of images (SS). Image processing included contrast equalization and noise filtering. Sound canal volumes were obtained by a minimum threshold. For the IS, a fixed conservative threshold was chosen as the best compromise between instrumented canal and dentine whilst avoiding debris, resulting in instrumented canal plus empty spaces. Arithmetic and logical operations between sound and instrumented stacks were used to identify debris. Noninstrumented dentine was calculated using a minimum threshold in the IS and subtracting from the SS and total debris. Removed dentine volume was obtained by subtracting SS from IS. Quantitative data on total debris present in the root canal space after instrumentation, noninstrumented areas and removed dentine volume were obtained for each test case, as well as three-dimensional volume renderings. After standardization of acquisition, reconstruction and image processing micro-CT images, a quantitative approach for calculation of root canal biomechanical outcomes was achieved using free software. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Heimpel, George E.; Yang, Yi; Hill, Jason D.; Ragsdale, David W.
2013-01-01
Greenhouse gas emissions associated with pesticide applications against invasive species constitute an environmental cost of species invasions that has remained largely unrecognized. Here we calculate greenhouse gas emissions associated with the invasion of an agricultural pest from Asia to North America. The soybean aphid, Aphis glycines, was first discovered in North America in 2000, and has led to a substantial increase in insecticide use in soybeans. We estimate that the manufacture, transport, and application of insecticides against soybean aphid results in approximately 10.6 kg of carbon dioxide (CO2) equivalent greenhouse gasses being emitted per hectare of soybeans treated. Given the acreage sprayed, this has led to annual emissions of between 6 and 40 million kg of CO2 equivalent greenhouse gasses in the United States since the invasion of soybean aphid, depending on pest population size. Emissions would be higher were it not for the development of a threshold aphid density below which farmers are advised not to spray. Without a threshold, farmers tend to spray preemptively and the threshold allows farmers to take advantage of naturally occurring biological control of the soybean aphid, which can be substantial. We find that adoption of the soybean aphid economic threshold can lead to emission reductions of approximately 300 million kg of CO2 equivalent greenhouse gases per year in the United States. Previous studies have documented that biological control agents such as lady beetles are capable of suppressing aphid densities below this threshold in over half of the soybean acreage in the U.S. Given the acreages involved this suggests that biological control results in annual emission reductions of over 200 million kg of CO2 equivalents. These analyses show how interactions between invasive species and organisms that suppress them can interact to affect greenhouse gas emissions. PMID:23977273
Heimpel, George E; Yang, Yi; Hill, Jason D; Ragsdale, David W
2013-01-01
Greenhouse gas emissions associated with pesticide applications against invasive species constitute an environmental cost of species invasions that has remained largely unrecognized. Here we calculate greenhouse gas emissions associated with the invasion of an agricultural pest from Asia to North America. The soybean aphid, Aphis glycines, was first discovered in North America in 2000, and has led to a substantial increase in insecticide use in soybeans. We estimate that the manufacture, transport, and application of insecticides against soybean aphid results in approximately 10.6 kg of carbon dioxide (CO2) equivalent greenhouse gasses being emitted per hectare of soybeans treated. Given the acreage sprayed, this has led to annual emissions of between 6 and 40 million kg of CO2 equivalent greenhouse gasses in the United States since the invasion of soybean aphid, depending on pest population size. Emissions would be higher were it not for the development of a threshold aphid density below which farmers are advised not to spray. Without a threshold, farmers tend to spray preemptively and the threshold allows farmers to take advantage of naturally occurring biological control of the soybean aphid, which can be substantial. We find that adoption of the soybean aphid economic threshold can lead to emission reductions of approximately 300 million kg of CO2 equivalent greenhouse gases per year in the United States. Previous studies have documented that biological control agents such as lady beetles are capable of suppressing aphid densities below this threshold in over half of the soybean acreage in the U.S. Given the acreages involved this suggests that biological control results in annual emission reductions of over 200 million kg of CO2 equivalents. These analyses show how interactions between invasive species and organisms that suppress them can interact to affect greenhouse gas emissions.
A Sound Pressure-level Meter Without Amplification
NASA Technical Reports Server (NTRS)
Stowell, E Z
1937-01-01
The N.A.C.A. has developed a simple pressure-level meter for the measurement of sound-pressure levels above 70 db. The instrument employs a carbon microphone but has no amplification. The source of power is five flashlight batteries. Measurements may be made up to the threshold of feeling with an accuracy of plus or minus 2 db; band analysis of complex spectra may be made if desired.
Von Benda-Beckmann, Alexander M; Wensveen, Paul J; Kvadsheim, Petter H; Lam, Frans-Peter A; Miller, Patrick J O; Tyack, Peter L; Ainslie, Michael A
2014-02-01
Ramp-up or soft-start procedures (i.e., gradual increase in the source level) are used to mitigate the effect of sonar sound on marine mammals, although no one to date has tested whether ramp-up procedures are effective at reducing the effect of sound on marine mammals. We investigated the effectiveness of ramp-up procedures in reducing the area within which changes in hearing thresholds can occur. We modeled the level of sound killer whales (Orcinus orca) were exposed to from a generic sonar operation preceded by different ramp-up schemes. In our model, ramp-up procedures reduced the risk of killer whales receiving sounds of sufficient intensity to affect their hearing. The effectiveness of the ramp-up procedure depended strongly on the assumed response threshold and differed with ramp-up duration, although extending the duration of the ramp up beyond 5 min did not add much to its predicted mitigating effect. The main factors that limited effectiveness of ramp up in a typical antisubmarine warfare scenario were high source level, rapid moving sonar source, and long silences between consecutive sonar transmissions. Our exposure modeling approach can be used to evaluate and optimize mitigation procedures. © 2013 Society for Conservation Biology.
Jin, Chao; Li, Huan; Li, Xianjun; Wang, Miaomiao; Liu, Congcong; Guo, Jianxin; Yang, Jian
2018-02-01
Purpose To determine whether a single 51-minute exposure to acoustic noise during 3-T multisequence magnetic resonance (MR) neuroimaging could affect the hearing threshold of healthy adults with earplugs and sponge mats as hearing protection. Materials and Methods With earplugs and motion-refraining sponge mats as hearing protection, 26 healthy young adults underwent 3-T MR neuroimaging imaging that included T1-weighted three-dimensional gradient-echo sequence, T2-weighted fast spin-echo sequence, diffusion-tensor imaging, diffusion-kurtosis imaging, T2*-weighted three-dimensional multiecho gradient-echo sequence, and blood oxygen level-dependent imaging. Automated auditory brainstem response (ABR) was used to measure the hearing thresholds within 24 hours before, within 20 minutes after, and 25 days after the MR examination. One-way repeated-measure analysis of variance with Bonferroni adjustment was used to compare automated ABR results among the three tests and partial η 2 (η p 2 ) was reported as a measure of effect size. Results Automated ABR results showed significantly increased mean threshold shift of 5.0 dB ± 8.1 (standard deviation) (left ear: 4.8 dB ± 9.2 [95% confidence interval: 1.09, 8.53], η p 2 = 0.221, P = .013; right ear: 5.2 dB ± 6.9 [95% confidence interval: 2.36, 8.02], η p 2 = 0.364, P = .001) immediately after the MR examination compared with the baseline study. This shift is below the temporary threshold shift of 40-50 dB that is associated with cochlea nerve changes. Automated ABR obtained at day 25 after MR imaging showed no significant differences from baseline (left ear: -2.3 dB ± 8.6 [95% confidence interval: -5.79, 1.78], η p 2 = 0.069, P = .185; right ear: 0.4 dB ± 7.3 [95% confidence interval: -3.35, 2.58], η p 2 = 0.003, P = .791). Conclusion A 3-T MR neuroimaging examination with the acoustic noise at equivalent sound pressure level of 103.5-111.3 dBA lasting 51 minutes can cause temporary hearing threshold shift in healthy volunteers with hearing protection. © RSNA, 2017.
Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise.
Nechaev, Dmitry I; Milekhina, Olga N; Supin, Alexander Ya
2015-01-01
The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels.
Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise
Nechaev, Dmitry I.; Milekhina, Olga N.; Supin, Alexander Ya.
2015-01-01
The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels. PMID:26462066
Hybrid local piezoelectric and conductive functions for high performance airborne sound absorption
NASA Astrophysics Data System (ADS)
Rahimabady, Mojtaba; Statharas, Eleftherios Christos; Yao, Kui; Sharifzadeh Mirshekarloo, Meysam; Chen, Shuting; Tay, Francis Eng Hock
2017-12-01
A concept of hybrid local piezoelectric and electrical conductive functions for improving airborne sound absorption is proposed and demonstrated in composite foam made of porous polar polyvinylidene fluoride (PVDF) mixed with conductive single-walled carbon nanotube (SWCNT). According to our hybrid material function design, the local piezoelectric effect in the PVDF matrix with the polar structure and the electrical resistive loss of SWCNT enhanced sound energy conversion to electrical energy and subsequently to thermal energy, respectively, in addition to the other known sound absorption mechanisms in a porous material. It is found that the overall energy conversion and hence the sound absorption performance are maximized when the concentration of the SWCNT is around the conductivity percolation threshold. For the optimal composition of PVDF/5 wt. % SWCNT, a sound reduction coefficient of larger than 0.58 has been obtained, with a high sound absorption coefficient higher than 50% at 600 Hz, showing their great values for passive noise mitigation even at a low frequency.
Knudson, Inge M; Melcher, Jennifer R
2016-06-01
Increases in the acoustic startle response (ASR) of animals have been reported following experimental manipulations to induce tinnitus, an auditory disorder defined by phantom perception of sound. The increases in ASR have been proposed to signify the development of hyperacusis, a clinical condition defined by intolerance of normally tolerable sound levels. To test this proposal, the present study compared ASR amplitude to measures of sound-level tolerance (SLT) in humans, the only species in which SLT can be directly assessed. Participants had clinically normal/near-normal hearing thresholds, were free of psychotropic medications, and comprised people with tinnitus and without. ASR was measured as eyeblink-related electromyographic activity in response to a noise pulse presented at a range of levels and in two background conditions (noise and quiet). SLT was measured as loudness discomfort level (LDL), the lowest level of sound deemed uncomfortable, and via a questionnaire on the loudness of sounds in everyday life. Regardless of tinnitus status, ASR amplitude at a given stimulus level increased with decreasing LDL, but showed no relationship to SLT self-reported via the questionnaire. These relationships (or lack thereof) could not be attributed to hearing threshold, age, anxiety, or depression. The results imply that increases in ASR in the animal work signify decreases in LDL specifically and may not correspond to the development of hyperacusis as would be self-reported by a clinic patient.
Efficient method for events detection in phonocardiographic signals
NASA Astrophysics Data System (ADS)
Martinez-Alajarin, Juan; Ruiz-Merino, Ramon
2005-06-01
The auscultation of the heart is still the first basic analysis tool used to evaluate the functional state of the heart, as well as the first indicator used to submit the patient to a cardiologist. In order to improve the diagnosis capabilities of auscultation, signal processing algorithms are currently being developed to assist the physician at primary care centers for adult and pediatric population. A basic task for the diagnosis from the phonocardiogram is to detect the events (main and additional sounds, murmurs and clicks) present in the cardiac cycle. This is usually made by applying a threshold and detecting the events that are bigger than the threshold. However, this method usually does not allow the detection of the main sounds when additional sounds and murmurs exist, or it may join several events into a unique one. In this paper we present a reliable method to detect the events present in the phonocardiogram, even in the presence of heart murmurs or additional sounds. The method detects relative maxima peaks in the amplitude envelope of the phonocardiogram, and computes a set of parameters associated with each event. Finally, a set of characteristics is extracted from each event to aid in the identification of the events. Besides, the morphology of the murmurs is also detected, which aids in the differentiation of different diseases that can occur in the same temporal localization. The algorithms have been applied to real normal heart sounds and murmurs, achieving satisfactory results.
Emergence of band-pass filtering through adaptive spiking in the owl's cochlear nucleus
MacLeod, Katrina M.; Lubejko, Susan T.; Steinberg, Louisa J.; Köppl, Christine; Peña, Jose L.
2014-01-01
In the visual, auditory, and electrosensory modalities, stimuli are defined by first- and second-order attributes. The fast time-pressure signal of a sound, a first-order attribute, is important, for instance, in sound localization and pitch perception, while its slow amplitude-modulated envelope, a second-order attribute, can be used for sound recognition. Ascending the auditory pathway from ear to midbrain, neurons increasingly show a preference for the envelope and are most sensitive to particular envelope modulation frequencies, a tuning considered important for encoding sound identity. The level at which this tuning property emerges along the pathway varies across species, and the mechanism of how this occurs is a matter of debate. In this paper, we target the transition between auditory nerve fibers and the cochlear nucleus angularis (NA). While the owl's auditory nerve fibers simultaneously encode the fast and slow attributes of a sound, one synapse further, NA neurons encode the envelope more efficiently than the auditory nerve. Using in vivo and in vitro electrophysiology and computational analysis, we show that a single-cell mechanism inducing spike threshold adaptation can explain the difference in neural filtering between the two areas. We show that spike threshold adaptation can explain the increased selectivity to modulation frequency, as input level increases in NA. These results demonstrate that a spike generation nonlinearity can modulate the tuning to second-order stimulus features, without invoking network or synaptic mechanisms. PMID:24790170
Efficient techniques for wave-based sound propagation in interactive applications
NASA Astrophysics Data System (ADS)
Mehra, Ravish
Sound propagation techniques model the effect of the environment on sound waves and predict their behavior from point of emission at the source to the final point of arrival at the listener. Sound is a pressure wave produced by mechanical vibration of a surface that propagates through a medium such as air or water, and the problem of sound propagation can be formulated mathematically as a second-order partial differential equation called the wave equation. Accurate techniques based on solving the wave equation, also called the wave-based techniques, are too expensive computationally and memory-wise. Therefore, these techniques face many challenges in terms of their applicability in interactive applications including sound propagation in large environments, time-varying source and listener directivity, and high simulation cost for mid-frequencies. In this dissertation, we propose a set of efficient wave-based sound propagation techniques that solve these three challenges and enable the use of wave-based sound propagation in interactive applications. Firstly, we propose a novel equivalent source technique for interactive wave-based sound propagation in large scenes spanning hundreds of meters. It is based on the equivalent source theory used for solving radiation and scattering problems in acoustics and electromagnetics. Instead of using a volumetric or surface-based approach, this technique takes an object-centric approach to sound propagation. The proposed equivalent source technique generates realistic acoustic effects and takes orders of magnitude less runtime memory compared to prior wave-based techniques. Secondly, we present an efficient framework for handling time-varying source and listener directivity for interactive wave-based sound propagation. The source directivity is represented as a linear combination of elementary spherical harmonic sources. This spherical harmonic-based representation of source directivity can support analytical, data-driven, rotating or time-varying directivity function at runtime. Unlike previous approaches, the listener directivity approach can be used to compute spatial audio (3D audio) for a moving, rotating listener at interactive rates. Lastly, we propose an efficient GPU-based time-domain solver for the wave equation that enables wave simulation up to the mid-frequency range in tens of minutes on a desktop computer. It is demonstrated that by carefully mapping all the components of the wave simulator to match the parallel processing capabilities of the graphics processors, significant improvement in performance can be achieved compared to the CPU-based simulators, while maintaining numerical accuracy. We validate these techniques with offline numerical simulations and measured data recorded in an outdoor scene. We present results of preliminary user evaluations conducted to study the impact of these techniques on user's immersion in virtual environment. We have integrated these techniques with the Half-Life 2 game engine, Oculus Rift head-mounted display, and Xbox game controller to enable users to experience high-quality acoustics effects and spatial audio in the virtual environment.
Hodgetts, William; Scott, Dylan; Maas, Patrick; Westover, Lindsey
2018-03-23
To determine if a newly-designed, forehead-mounted surface microphone would yield equivalent estimates of audibility when compared to audibility measured with a skull simulator for adult bone conduction users. Data was analyzed using a within subjects, repeated measures design. There were two different sensors (skull simulator and surface microphone) measuring the same hearing aid programmed to the same settings for all subjects. We were looking for equivalent results. Twenty-one adult percutaneous bone conduction users (12 females and 9 males) were recruited for this study. Mean age was 54.32 years with a standard deviation of 14.51 years. Nineteen of the subjects had conductive/mixed hearing loss and two had single-sided deafness. To define audibility, we needed to establish two things: (1) in situ-level thresholds at each audiometric frequency in force (skull simulator) and in sound pressure level (SPL; surface microphone). Next, we measured the responses of the preprogrammed test device in force on the skull simulator and in SPL on the surface mic in response to pink noise at three input levels: 55, 65, and 75 dB SPL. The skull simulator responses were converted to real head force responses by means of an individual real head to coupler difference transform. Subtracting the real head force level thresholds from the real head force output of the test aid yielded the audibility for each audiometric frequency for the skull simulator. Subtracting the SPL thresholds from the surface microphone from the SPL output of the test aid yielded the audibility for each audiometric frequency for the surface microphone. The surface microphone was removed and retested to establish the test-retest reliability of the tool. We ran a 2 (sensor) × 3 (input level) × 10 (frequency) mixed analysis of variance to determine if there were any significant main effects and interactions. There was a significant three-way interaction, so we proceeded to explore our planned comparisons. There were 90 planned comparisons of interest, three at each frequency (3 × 10) for the three input levels (30 × 3). Therefore, to minimize a type 1 error associated with multiple comparisons, we adjusted alpha using the Holm-Bonferroni method. There were five comparisons that yielded significant differences between the skull simulator and surface microphone (test and retest) in the estimation of audibility. However, the mean difference in these effects was small at 3.3 dB. Both sensors yielded equivalent results for the majority of comparisons. Models of bone conduction devices that have intact skin cannot be measured with the skull simulator. This study is the first to present and evaluate a new tool for bone conduction verification. The surface microphone is capable of yielding equivalent audibility measurements as the skull simulator for percutaneous bone conduction users at multiple input levels. This device holds potential for measuring other bone conduction devices (Sentio, BoneBridge, Attract, Soft headband devices) that do not have a percutaneous implant.
Establishing the Response of Low Frequency Auditory Filters
NASA Technical Reports Server (NTRS)
Rafaelof, Menachem; Christian, Andrew; Shepherd, Kevin; Rizzi, Stephen; Stephenson, James
2017-01-01
The response of auditory filters is central to frequency selectivity of sound by the human auditory system. This is true especially for realistic complex sounds that are often encountered in many applications such as modeling the audibility of sound, voice recognition, noise cancelation, and the development of advanced hearing aid devices. The purpose of this study was to establish the response of low frequency (below 100Hz) auditory filters. Two experiments were designed and executed; the first was to measure subject's hearing threshold for pure tones (at 25, 31.5, 40, 50, 63 and 80 Hz), and the second was to measure the Psychophysical Tuning Curves (PTCs) at two signal frequencies (Fs= 40 and 63Hz). Experiment 1 involved 36 subjects while experiment 2 used 20 subjects selected from experiment 1. Both experiments were based on a 3-down 1-up 3AFC adaptive staircase test procedure using either a variable level narrow-band noise masker or a tone. A summary of the results includes masked threshold data in form of PTCs, the response of auditory filters, their distribution, and comparison with similar recently published data.
The EarLens System: New Sound Transduction Methods
Perkins, Rodney; Fay, Jonathan P.; Rucker, Paul; Rosen, Micha; Olson, Lisa; Puria, Sunil
2010-01-01
The hypothesis is tested that an open-canal hearing device, with a microphone in the ear canal, can be designed to provide amplification over a wide bandwidth and without acoustic feedback. In the design under consideration, a transducer consisting of a thin silicone platform with an embedded magnet is placed directly on the tympanic membrane. Sound picked up by a microphone in the ear canal, including sound-localization cues thought to be useful for speech perception in noisy environments, is processed and amplified, and then used to drive a coil near the tympanic-membrane transducer. The perception of sound results from the vibration of the transducer in response the electromagnetic field produced by the coil. Sixteen subjects (ranging from normal-hearing to moderately hearing-impaired) wore this transducer for up to a ten-month period, and were monitored for any adverse reactions. Three key functional characteristics were measured: 1) the maximum equivalent pressure output (MEPO) of the transducer; 2) the feedback gain margin (GM), which describes the maximum allowable gain before feedback occurs; and 3) the tympanic-membrane damping effect (DTM), which describes the change in hearing level due to placement of the transducer on the eardrum. Results indicate that the tympanic-membrane transducer remains in place and is well tolerated. The system can produce sufficient output to reach threshold for those with as much as 60 dBHL of hearing impairment for up to 8 kHz in 86% of the study population, and up to 11.2 kHz in 50% of the population. The feedback gain margin is on average 30 dB except at the ear canal resonance frequencies of 3 and 9 kHz, where the average was reduced to 12 dB and 23 dB respectively. The average value of DTM is close to 0 dB everywhere except in the 2–4 kHz range, where it peaks at 8 dB. A new alternative system that uses photonic energy to transmit both the signal and power to a photodiode and micro-actuator on an EarLens platform is also described. PMID:20116419
Regression Verification Using Impact Summaries
NASA Technical Reports Server (NTRS)
Backes, John; Person, Suzette J.; Rungta, Neha; Thachuk, Oksana
2013-01-01
Regression verification techniques are used to prove equivalence of syntactically similar programs. Checking equivalence of large programs, however, can be computationally expensive. Existing regression verification techniques rely on abstraction and decomposition techniques to reduce the computational effort of checking equivalence of the entire program. These techniques are sound but not complete. In this work, we propose a novel approach to improve scalability of regression verification by classifying the program behaviors generated during symbolic execution as either impacted or unimpacted. Our technique uses a combination of static analysis and symbolic execution to generate summaries of impacted program behaviors. The impact summaries are then checked for equivalence using an o-the-shelf decision procedure. We prove that our approach is both sound and complete for sequential programs, with respect to the depth bound of symbolic execution. Our evaluation on a set of sequential C artifacts shows that reducing the size of the summaries can help reduce the cost of software equivalence checking. Various reduction, abstraction, and compositional techniques have been developed to help scale software verification techniques to industrial-sized systems. Although such techniques have greatly increased the size and complexity of systems that can be checked, analysis of large software systems remains costly. Regression analysis techniques, e.g., regression testing [16], regression model checking [22], and regression verification [19], restrict the scope of the analysis by leveraging the differences between program versions. These techniques are based on the idea that if code is checked early in development, then subsequent versions can be checked against a prior (checked) version, leveraging the results of the previous analysis to reduce analysis cost of the current version. Regression verification addresses the problem of proving equivalence of closely related program versions [19]. These techniques compare two programs with a large degree of syntactic similarity to prove that portions of one program version are equivalent to the other. Regression verification can be used for guaranteeing backward compatibility, and for showing behavioral equivalence in programs with syntactic differences, e.g., when a program is refactored to improve its performance, maintainability, or readability. Existing regression verification techniques leverage similarities between program versions by using abstraction and decomposition techniques to improve scalability of the analysis [10, 12, 19]. The abstractions and decomposition in the these techniques, e.g., summaries of unchanged code [12] or semantically equivalent methods [19], compute an over-approximation of the program behaviors. The equivalence checking results of these techniques are sound but not complete-they may characterize programs as not functionally equivalent when, in fact, they are equivalent. In this work we describe a novel approach that leverages the impact of the differences between two programs for scaling regression verification. We partition program behaviors of each version into (a) behaviors impacted by the changes and (b) behaviors not impacted (unimpacted) by the changes. Only the impacted program behaviors are used during equivalence checking. We then prove that checking equivalence of the impacted program behaviors is equivalent to checking equivalence of all program behaviors for a given depth bound. In this work we use symbolic execution to generate the program behaviors and leverage control- and data-dependence information to facilitate the partitioning of program behaviors. The impacted program behaviors are termed as impact summaries. The dependence analyses that facilitate the generation of the impact summaries, we believe, could be used in conjunction with other abstraction and decomposition based approaches, [10, 12], as a complementary reduction technique. An evaluation of our regression verification technique shows that our approach is capable of leveraging similarities between program versions to reduce the size of the queries and the time required to check for logical equivalence. The main contributions of this work are: - A regression verification technique to generate impact summaries that can be checked for functional equivalence using an off-the-shelf decision procedure. - A proof that our approach is sound and complete with respect to the depth bound of symbolic execution. - An implementation of our technique using the LLVMcompiler infrastructure, the klee Symbolic Virtual Machine [4], and a variety of Satisfiability Modulo Theory (SMT) solvers, e.g., STP [7] and Z3 [6]. - An empirical evaluation on a set of C artifacts which shows that the use of impact summaries can reduce the cost of regression verification.
Cell openness manipulation of low density polyurethane foam for efficient sound absorption
NASA Astrophysics Data System (ADS)
Hyuk Park, Ju; Suh Minn, Kyung; Rae Lee, Hyeong; Hyun Yang, Sei; Bin Yu, Cheng; Yeol Pak, Seong; Sung Oh, Chi; Seok Song, Young; June Kang, Yeon; Ryoun Youn, Jae
2017-10-01
Satisfactory sound absorption using a low mass density foam is an intriguing desire for achieving high fuel efficiency of vehicles. This issue has been dealt with a microcellular geometry manipulation. In this study, we demonstrate the relationship between cell openness of polyurethane (PU) foam and sound absorption behaviors, both theoretically and experimentally. The objective of this work is to mitigate a threshold of mass density by rendering a sound absorber which shows a satisfactory performance. The cell openness, which causes the best sound absorption performance in all cases considered, was estimated as 15% by numerical simulation. Cell openness of PU foam was experimentally manipulated into desired ranges by adjusting rheological properties in a foaming reaction. Microcellular structures of the fabricated PU foams were observed and sound absorption coefficients were measured using a B&K impedance tube. The fabricated PU foam with the best cell openness showed better sound absorption performance than the foam with double mass density. We envisage that this study can help the manufacture of low mass density sound absorbing foams more efficiently and economically.
Emotional processing modulates attentional capture of irrelevant sound input in adolescents.
Gulotta, B; Sadia, G; Sussman, E
2013-04-01
The main goal of this study was to investigate how emotional processing modulates the allocation of attention to irrelevant background sound events in adolescence. We examined the effect of viewing positively and negatively valenced video clips on components of event-related brain potentials (ERPs), while irrelevant sounds were presented to the ears. All sounds evoked the P1, N1, P2, and N2 components. The infrequent, randomly occurring novel environmental sounds evoked the P3a component in all trial types. The main finding was that the P3a component was larger in amplitude when evoked by salient, distracting background sound events when participants were watching negatively charged video clips, compared to when viewing of the positive or neutral video clips. The results suggest that the threshold for involuntary attention to the novel sounds was lowered during viewing of the negative movie contexts. This indicates a survival mechanism, which would be needed for more automatic processing of irrelevant sounds to monitor the unattended environment in situations perceived as more threatening. Copyright © 2012 Elsevier B.V. All rights reserved.
Replacing the Orchestra? – The Discernibility of Sample Library and Live Orchestra Sounds
Wolf, Anna; Platz, Friedrich; Mons, Jan
2016-01-01
Recently, musical sounds from pre-recorded orchestra sample libraries (OSL) have become indispensable in music production for the stage or popular charts. Surprisingly, it is unknown whether human listeners can identify sounds as stemming from real orchestras or OSLs. Thus, an internet-based experiment was conducted to investigate whether a classic orchestral work, produced with sounds from a state-of-the-art OSL, could be reliably discerned from a live orchestra recording of the piece. It could be shown that the entire sample of listeners (N = 602) on average identified the correct sound source at 72.5%. This rate slightly exceeded Alan Turing's well-known upper threshold of 70% for a convincing, simulated performance. However, while sound experts tended to correctly identify the sound source, participants with lower listening expertise, who resembled the majority of music consumers, only achieved 68.6%. As non-expert listeners in the experiment were virtually unable to tell the real-life and OSL sounds apart, it is assumed that OSLs will become more common in music production for economic reasons. PMID:27382932
NASA Astrophysics Data System (ADS)
Farag, Karam S. I.; Abd El-Aal, Mohamed H.; Garamoon, Hassan K. F.
2018-07-01
A joint azimuthal very low frequency-electromagnetic (VLF-EM) and DC-resistivity sounding survey was conducted at the new Ain Shams university campus in Al-Obour city, northwest of Cairo, Egypt. The main objective of the survey was to highlight the applicability and reliability of such non-invasive surface techniques in mapping and monitoring both the vertical and lateral electrical conductivity structures of waterlogged areas, by subterraneous water accumulations, at the campus site. Consequently, a total of 743 azimuthal VLF-EM and 4 DC-resistivity soundings were carried out in June, 2011, 2012 and 2013. The data were interpreted extensively and consistently in terms of two-dimensional (2D) transformed EM equivalent current-density and stitched inverted electrical resistivity models, without using any geological a-priori information. They could be used effectively to image the local anomalous lower electrical resistivity (higher EM equivalent current-density) structures and their near-surface spreading with time, due to the excessive accumulations of subterraneous water at the campus site. The study demonstrated that a regional azimuthal VLF-EM and DC-resistivity sounding survey could help design an optimal dewatering program for the whole city, at greatly reduced execution time.
An Evaluation of Psychophysical Models of Auditory Change Perception
Micheyl, Christophe; Kaernbach, Christian; Demany, Laurent
2009-01-01
In many psychophysical experiments, the participant's task is to detect small changes along a given stimulus dimension, or to identify the direction (e.g., upward vs. downward) of such changes. The results of these experiments are traditionally analyzed using a constant-variance Gaussian (CVG) model or a high-threshold (HT) model. Here, the authors demonstrate that for changes along three basic sound dimensions (frequency, intensity, and amplitude-modulation rate), such models cannot account for the observed relationship between detection thresholds and direction-identification thresholds. It is shown that two alternative models can account for this relationship. One of them is based on the idea of sensory “quanta”; the other assumes that small changes are detected on the basis of Poisson processes with low means. The predictions of these two models are then compared against receiver operating characteristics (ROCs) for the detection of changes in sound intensity. It is concluded that human listeners' perception of small and unidimensional acoustic changes is better described by a discrete-state Poisson model than by the more commonly used CVG model or by the less favored HT and quantum models. PMID:18954215
Automated segmentation of linear time-frequency representations of marine-mammal sounds.
Dadouchi, Florian; Gervaise, Cedric; Ioana, Cornel; Huillery, Julien; Mars, Jérôme I
2013-09-01
Many marine mammals produce highly nonlinear frequency modulations. Determining the time-frequency support of these sounds offers various applications, which include recognition, localization, and density estimation. This study introduces a low parameterized automated spectrogram segmentation method that is based on a theoretical probabilistic framework. In the first step, the background noise in the spectrogram is fitted with a Chi-squared distribution and thresholded using a Neyman-Pearson approach. In the second step, the number of false detections in time-frequency regions is modeled as a binomial distribution, and then through a Neyman-Pearson strategy, the time-frequency bins are gathered into regions of interest. The proposed method is validated on real data of large sequences of whistles from common dolphins, collected in the Bay of Biscay (France). The proposed method is also compared with two alternative approaches: the first is smoothing and thresholding of the spectrogram; the second is thresholding of the spectrogram followed by the use of morphological operators to gather the time-frequency bins and to remove false positives. This method is shown to increase the probability of detection for the same probability of false alarms.
NASA Astrophysics Data System (ADS)
Naghibolhosseini, Maryam; Long, Glenis
2011-11-01
The distortion product otoacoustic emission (DPOAE) input/output (I/O) function may provide a potential tool for evaluating cochlear compression. Hearing loss causes an increase in the level of the sound that is just audible for the person, which affects the cochlea compression and thus the dynamic range of hearing. Although the slope of the I/O function is highly variable when the total DPOAE is used, separating the nonlinear-generator component from the reflection component reduces this variability. We separated the two components using least squares fit (LSF) analysis of logarithmic sweeping tones, and confirmed that the separated generator component provides more consistent I/O functions than the total DPOAE. In this paper we estimated the slope of the I/O functions of the generator components at different sound levels using LSF analysis. An artificial neural network (ANN) was used to estimate psychophysical thresholds using the estimated slopes of the I/O functions. DPOAE I/O functions determined in this way may help to estimate hearing thresholds and cochlear health.
Dependence of cavitation, chemical effect, and mechanical effect thresholds on ultrasonic frequency.
Thanh Nguyen, Tam; Asakura, Yoshiyuki; Koda, Shinobu; Yasuda, Keiji
2017-11-01
Cavitation, chemical effect, and mechanical effect thresholds were investigated in wide frequency ranges from 22 to 4880kHz. Each threshold was measured in terms of sound pressure at fundamental frequency. Broadband noise emitted from acoustic cavitation bubbles was detected by a hydrophone to determine the cavitation threshold. Potassium iodide oxidation caused by acoustic cavitation was used to quantify the chemical effect threshold. The ultrasonic erosion of aluminum foil was conducted to estimate the mechanical effect threshold. The cavitation, chemical effect, and mechanical effect thresholds increased with increasing frequency. The chemical effect threshold was close to the cavitation threshold for all frequencies. At low frequency below 98kHz, the mechanical effect threshold was nearly equal to the cavitation threshold. However, the mechanical effect threshold was greatly higher than the cavitation threshold at high frequency. In addition, the thresholds of the second harmonic and the first ultraharmonic signals were measured to detect bubble occurrence. The threshold of the second harmonic approximated to the cavitation threshold below 1000kHz. On the other hand, the threshold of the first ultraharmonic was higher than the cavitation threshold below 98kHz and near to the cavitation threshold at high frequency. Copyright © 2017 Elsevier B.V. All rights reserved.
Linear models for sound from supersonic reacting mixing layers
NASA Astrophysics Data System (ADS)
Chary, P. Shivakanth; Samanta, Arnab
2016-12-01
We perform a linearized reduced-order modeling of the aeroacoustic sound sources in supersonic reacting mixing layers to explore their sensitivities to some of the flow parameters in radiating sound. Specifically, we investigate the role of outer modes as the effective flow compressibility is raised, when some of these are expected to dominate over the traditional Kelvin-Helmholtz (K-H) -type central mode. Although the outer modes are known to be of lesser importance in the near-field mixing, how these radiate to the far-field is uncertain, on which we focus. On keeping the flow compressibility fixed, the outer modes are realized via biasing the respective mean densities of the fast (oxidizer) or slow (fuel) side. Here the mean flows are laminar solutions of two-dimensional compressible boundary layers with an imposed composite (turbulent) spreading rate, which we show to significantly alter the growth of instability waves by saturating them earlier, similar to in nonlinear calculations, achieved here via solving the linear parabolized stability equations. As the flow parameters are varied, instability of the slow modes is shown to be more sensitive to heat release, potentially exceeding equivalent central modes, as these modes yield relatively compact sound sources with lesser spreading of the mixing layer, when compared to the corresponding fast modes. In contrast, the radiated sound seems to be relatively unaffected when the mixture equivalence ratio is varied, except for a lean mixture which is shown to yield a pronounced effect on the slow mode radiation by reducing its modal growth.
Heil, Peter; Matysiak, Artur; Neubauer, Heinrich
2017-09-01
Thresholds for detecting sounds in quiet decrease with increasing sound duration in every species studied. The neural mechanisms underlying this trade-off, often referred to as temporal integration, are not fully understood. Here, we probe the human auditory system with a large set of tone stimuli differing in duration, shape of the temporal amplitude envelope, duration of silent gaps between bursts, and frequency. Duration was varied by varying the plateau duration of plateau-burst (PB) stimuli, the duration of the onsets and offsets of onset-offset (OO) stimuli, and the number of identical bursts of multiple-burst (MB) stimuli. Absolute thresholds for a large number of ears (>230) were measured using a 3-interval-3-alternative forced choice (3I-3AFC) procedure. Thresholds decreased with increasing sound duration in a manner that depended on the temporal envelope. Most commonly, thresholds for MB stimuli were highest followed by thresholds for OO and PB stimuli of corresponding durations. Differences in the thresholds for MB and OO stimuli and in the thresholds for MB and PB stimuli, however, varied widely across ears, were negative in some ears, and were tightly correlated. We show that the variation and correlation of MB-OO and MB-PB threshold differences are linked to threshold microstructure, which affects the relative detectability of the sidebands of the MB stimuli and affects estimates of the bandwidth of auditory filters. We also found that thresholds for MB stimuli increased with increasing duration of the silent gaps between bursts. We propose a new model and show that it accurately accounts for our results and does so considerably better than a leaky-integrator-of-intensity model and a probabilistic model proposed by others. Our model is based on the assumption that sensory events are generated by a Poisson point process with a low rate in the absence of stimulation and higher, time-varying rates in the presence of stimulation. A subject in a 3I-3AFC task is assumed to choose the interval in which the greatest number of events occurred or randomly chooses among intervals which are tied for the greatest number of events. The subject is further assumed to count events over the duration of an evaluation interval that has the same timing and duration as the expected stimulus. The increase in the rate of the events caused by stimulation is proportional to the time-varying amplitude envelope of the bandpass-filtered signal raised to an exponent. We find the exponent to be about 3, consistent with our previous studies. This challenges models that are based on the assumption of the integration of a neural response that is directly proportional to the stimulus amplitude or proportional to its square (i.e., proportional to the stimulus intensity or power). Copyright © 2017 Elsevier B.V. All rights reserved.
Critical Deposition Condition of CoNiCrAlY Cold Spray Based on Particle Deformation Behavior
NASA Astrophysics Data System (ADS)
Ichikawa, Yuji; Ogawa, Kazuhiro
2017-02-01
Previous research has demonstrated deposition of MCrAlY coating via the cold spray process; however, the deposition mechanism of cold spraying has not been clearly explained—only empirically described by impact velocity. The purpose of this study was to elucidate the critical deposit condition. Microscale experimental measurements of individual particle deposit dimensions were incorporated with numerical simulation to investigate particle deformation behavior. Dimensional parameters were determined from scanning electron microscopy analysis of focused ion beam-fabricated cross sections of deposited particles to describe the deposition threshold. From Johnson-Cook finite element method simulation results, there is a direct correlation between the dimensional parameters and the impact velocity. Therefore, the critical velocity can describe the deposition threshold. Moreover, the maximum equivalent plastic strain is also strongly dependent on the impact velocity. Thus, the threshold condition required for particle deposition can instead be represented by the equivalent plastic strain of the particle and substrate. For particle-substrate combinations of similar materials, the substrate is more difficult to deform. Thus, this study establishes that the dominant factor of particle deposition in the cold spray process is the maximum equivalent plastic strain of the substrate, which occurs during impact and deformation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... or equivalent arrangements are valid for the purposes of this section only if persons assuming... recycling, disposal or other means of sound management of the wastes in cases where arrangements for the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... or equivalent arrangements are valid for the purposes of this section only if persons assuming... recycling, disposal or other means of sound management of the wastes in cases where arrangements for the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... or equivalent arrangements are valid for the purposes of this section only if persons assuming... recycling, disposal or other means of sound management of the wastes in cases where arrangements for the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... or equivalent arrangements are valid for the purposes of this section only if persons assuming... recycling, disposal or other means of sound management of the wastes in cases where arrangements for the...
Optimization of valve opening process for the suppression of impulse exhaust noise
NASA Astrophysics Data System (ADS)
Li, Jingxiang; Zhao, Shengdun
2017-02-01
Impulse exhaust noise generated by the sudden impact of discharging flow of pneumatic systems has significant temporal characteristics including high sound pressure and rapid sound transient. The impulse noise exposures are more hazardous to hearing than the energy equivalent uniform noise exposures. This paper presents a novel approach to suppress the peak sound pressure as a major indicator of impulsiveness of the impulse exhaust noise by an optimization of the opening process of valve. Relationships between exhaust flow and impulse noise are described by thermodynamics and noise generating mechanism. Then an optimized approach by controlling the valve opening process is derived under a constraint of pre-setting exhaust time. A modified servo-direct-driven valve was designed and assembled in a typical pneumatic system for the verification experiments comparing with an original solenoid valve. Experimental results with groups of initial cylinder pressures and pre-setting exhaust times are shown to verify the effects of the proposed optimization. Some indicators of energy-equivalent and impulsiveness are introduced to discuss the effects of the noise suppressions. Relationship between noise reduction and exhaust time delay is also discussed.
Torija, Antonio J; Ruiz, Diego P; Ramos-Ridao, A F
2013-07-01
A subjective and physical categorization of an ambient sound is the first step to evaluate the soundscape and provides a basis for designing or adapting this ambient sound to match people's expectations. For this reason, the main goal of this work is to develop a categorization and differentiation analysis of soundscapes on the basis of acoustical and perceptual variables. A hierarchical cluster analysis, using 15 semantic-differential attributes and acoustical descriptors to include an equivalent sound-pressure level, maximum-minimum sound-pressure level, impulsiveness of the sound-pressure level, sound-pressure level time course, and spectral composition, was conducted to classify soundscapes into different typologies. This analysis identified 15 different soundscape typologies. Furthermore, based on a discriminant analysis the acoustical descriptors, the crest factor (impulsiveness of the sound-pressure level), and the sound level at 125 Hz were found to be the acoustical variables with the highest impact in the differentiation of the recognized types of soundscapes. Finally, to determine how the different soundscape typologies differed from each other, both subjectively and acoustically, a study was performed.
Marine mammal audibility of selected shallow-water survey sources.
MacGillivray, Alexander O; Racca, Roberto; Li, Zizheng
2014-01-01
Most attention about the acoustic effects of marine survey sound sources on marine mammals has focused on airgun arrays, with other common sources receiving less scrutiny. Sound levels above hearing threshold (sensation levels) were modeled for six marine mammal species and seven different survey sources in shallow water. The model indicated that odontocetes were most likely to hear sounds from mid-frequency sources (fishery, communication, and hydrographic systems), mysticetes from low-frequency sources (sub-bottom profiler and airguns), and pinnipeds from both mid- and low-frequency sources. High-frequency sources (side-scan and multibeam) generated the lowest estimated sensation levels for all marine mammal species groups.
NASA Astrophysics Data System (ADS)
Ueda, Daiki; Takeuchi, Kiyoshi; Kobayashi, Masaharu; Hiramoto, Toshiro
2018-04-01
A new circuit model that provides a clear guide on designing a MOS-gated thyristor (MGT) is reported. MGT plays a significant role in achieving a steep subthreshold slope of a PN-body tied silicon-on-insulator (SOI) FET (PNBTFET), which is an SOI MOSFET merged with an MGT. The effects of design parameters on MGT and the proposed equivalent circuit model are examined to determine how to regulate the voltage response of MGT and how to suppress power dissipation. It is demonstrated that MGT with low threshold voltages, small hysteresis widths, and small power dissipation can be designed by tuning design parameters. The temperature dependence of MGT is also examined, and it is confirmed that hysteresis width decreases with the average threshold voltage kept nearly constant as temperature rises. The equivalent circuit model can be conveniently used to design low-power PNBTFET.
Lowering the Percolation Threshold of Conductive Composites Using Particulate Polymer Microstructure
NASA Astrophysics Data System (ADS)
Grunlan, Jaime; Gerberich, William; Francis, Lorraine
2000-03-01
In an effort to lower the percolation threshold of carbon black-filled polymer composites, various polymer microstructures were examined. Composites were prepared using polyvinyl acetate (PVAc) latex, PVAc water-dispersible powder and polyvinylpyrrolidone (PVP) solution as the matrix starting material. Composites prepared using the particulate microstructures showed a significantly lowered percolation threshold relative to an equivalently prepared composite using the PVP solution. The PVAc latex-based composites has a percolation threshold of 3 volthe PVP solution-based composite yielded a percolation threshold near 15 voloccupied by polymer particles, the particulate matrix-based composites create a segregated CB network at low filler concentration.
Environmental Assessment: Installation Development at Sheppard Air Force Base, Texas
2007-05-01
column, or in topographic depressions. Water is then utilized by plants and is respired, or it moves slowly into groundwater and/or eventually to surface...water bodies where it slowly moves through the hydrologic cycle. Removal of vegetation decreases infiltration into the soil column and thereby...School District JP-4 jet propulsion fuel 4 kts knots Ldn Day- Night Average Sound Level Leq equivalent noise level Lmax maximum sound level lb pound
McClaine, Elizabeth M.; Yin, Tom C. T.
2010-01-01
The precedence effect (PE) is an auditory spatial illusion whereby two identical sounds presented from two separate locations with a delay between them are perceived as a fused single sound source whose position depends on the value of the delay. By training cats using operant conditioning to look at sound sources, we have previously shown that cats experience the PE similarly to humans. For delays less than ±400 μs, cats exhibit summing localization, the perception of a “phantom” sound located between the sources. Consistent with localization dominance, for delays from 400 μs to ∼10 ms, cats orient toward the leading source location only, with little influence of the lagging source. Finally, echo threshold was reached for delays >10 ms, where cats first began to orient to the lagging source. It has been hypothesized by some that the neural mechanisms that produce facets of the PE, such as localization dominance and echo threshold, must likely occur at cortical levels. To test this hypothesis, we measured both pinnae position, which were not under any behavioral constraint, and eye position in cats and found that the pinnae orientations to stimuli that produce each of the three phases of the PE illusion was similar to the gaze responses. Although both eye and pinnae movements behaved in a manner that reflected the PE, because the pinnae moved with strikingly short latencies (∼30 ms), these data suggest a subcortical basis for the PE and that the cortex is not likely to be directly involved. PMID:19889848
Tollin, Daniel J; McClaine, Elizabeth M; Yin, Tom C T
2010-01-01
The precedence effect (PE) is an auditory spatial illusion whereby two identical sounds presented from two separate locations with a delay between them are perceived as a fused single sound source whose position depends on the value of the delay. By training cats using operant conditioning to look at sound sources, we have previously shown that cats experience the PE similarly to humans. For delays less than +/-400 mus, cats exhibit summing localization, the perception of a "phantom" sound located between the sources. Consistent with localization dominance, for delays from 400 mus to approximately 10 ms, cats orient toward the leading source location only, with little influence of the lagging source. Finally, echo threshold was reached for delays >10 ms, where cats first began to orient to the lagging source. It has been hypothesized by some that the neural mechanisms that produce facets of the PE, such as localization dominance and echo threshold, must likely occur at cortical levels. To test this hypothesis, we measured both pinnae position, which were not under any behavioral constraint, and eye position in cats and found that the pinnae orientations to stimuli that produce each of the three phases of the PE illusion was similar to the gaze responses. Although both eye and pinnae movements behaved in a manner that reflected the PE, because the pinnae moved with strikingly short latencies ( approximately 30 ms), these data suggest a subcortical basis for the PE and that the cortex is not likely to be directly involved.
Weichenberger, Markus; Bauer, Martin; Kühler, Robert; Hensel, Johannes; Forlim, Caroline Garcia; Ihlenfeld, Albrecht; Ittermann, Bernd; Gallinat, Jürgen; Koch, Christian; Kühn, Simone
2017-01-01
In the present study, the brain’s response towards near- and supra-threshold infrasound (IS) stimulation (sound frequency < 20 Hz) was investigated under resting-state fMRI conditions. The study involved two consecutive sessions. In the first session, 14 healthy participants underwent a hearing threshold—as well as a categorical loudness scaling measurement in which the individual loudness perception for IS was assessed across different sound pressure levels (SPL). In the second session, these participants underwent three resting-state acquisitions, one without auditory stimulation (no-tone), one with a monaurally presented 12-Hz IS tone (near-threshold) and one with a similar tone above the individual hearing threshold corresponding to a ‘medium loud’ hearing sensation (supra-threshold). Data analysis mainly focused on local connectivity measures by means of regional homogeneity (ReHo), but also involved independent component analysis (ICA) to investigate inter-regional connectivity. ReHo analysis revealed significantly higher local connectivity in right superior temporal gyrus (STG) adjacent to primary auditory cortex, in anterior cingulate cortex (ACC) and, when allowing smaller cluster sizes, also in the right amygdala (rAmyg) during the near-threshold, compared to both the supra-threshold and the no-tone condition. Additional independent component analysis (ICA) revealed large-scale changes of functional connectivity, reflected in a stronger activation of the right amygdala (rAmyg) in the opposite contrast (no-tone > near-threshold) as well as the right superior frontal gyrus (rSFG) during the near-threshold condition. In summary, this study is the first to demonstrate that infrasound near the hearing threshold may induce changes of neural activity across several brain regions, some of which are known to be involved in auditory processing, while others are regarded as keyplayers in emotional and autonomic control. These findings thus allow us to speculate on how continuous exposure to (sub-)liminal IS could exert a pathogenic influence on the organism, yet further (especially longitudinal) studies are required in order to substantialize these findings. PMID:28403175
Writing on the Threshold: Investigating New Media Concerns in Composition Textbooks
ERIC Educational Resources Information Center
Etlinger, Sarah A.
2012-01-01
This dissertation examines three recent first-year composition textbooks' treatments of new media. These textbooks treat new media as equivalent to print media; I offer "media equivalency" to describe the problem. This concept suggests that one medium is understood by the same methods as another. I argue that the media equivalency…
ERIC Educational Resources Information Center
Yurtbasi, Metin
2017-01-01
The aim of this article is to present to the reader a specific sampling from the French phonological terminology collected from relevant literature with their equivalents in English, German and Turkish. There has been so far many linguistic studies and publications in the French sound system both by French and foreign scholars in form of books,…
Wilson, Uzma S.; Kaf, Wafaa A.; Danesh, Ali A.; Lichtenhan, Jeffery T.
2016-01-01
Objective To determine the clinical utility of narrow-band chirp evoked 40-Hz sinusoidal auditory steady state responses (s-ASSR) in the assessment of low-frequency hearing in noisy participants. Design Tone bursts and narrow-band chirps were used to respectively evoke auditory brainstem responses (tb-ABR) and 40-Hz s-ASSR thresholds with the Kalman-weighted filtering technique and were compared to behavioral thresholds at 500, 2000, and 4000 Hz. A repeated measure ANOVA and post-hoc t-tests, and simple regression analyses were performed for each of the three stimulus frequencies. Study Sample Thirty young adults aged 18–25 with normal hearing participated in this study. Results When 4000 equivalent responses averages were used, the range of mean s-ASSR thresholds from 500, 2000, and 4000 Hz were 17–22 dB lower (better) than when 2000 averages were used. The range of mean tb-ABR thresholds were lower by 11–15 dB for 2000 and 4000 Hz when twice as many equivalent response averages were used, while mean tb-ABR thresholds for 500 Hz were indistinguishable regardless of additional response averaging Conclusion Narrow band chirp evoked 40-Hz s-ASSR requires a ~15 dB smaller correction factor than tb-ABR for estimating low-frequency auditory threshold in noisy participants when adequate response averaging is used. PMID:26795555
Active room compensation for sound reinforcement using sound field separation techniques.
Heuchel, Franz M; Fernandez-Grande, Efren; Agerkvist, Finn T; Shabalina, Elena
2018-03-01
This work investigates how the sound field created by a sound reinforcement system can be controlled at low frequencies. An indoor control method is proposed which actively absorbs the sound incident on a reflecting boundary using an array of secondary sources. The sound field is separated into incident and reflected components by a microphone array close to the secondary sources, enabling the minimization of reflected components by means of optimal signals for the secondary sources. The method is purely feed-forward and assumes constant room conditions. Three different sound field separation techniques for the modeling of the reflections are investigated based on plane wave decomposition, equivalent sources, and the Spatial Fourier transform. Simulations and an experimental validation are presented, showing that the control method performs similarly well at enhancing low frequency responses with the three sound separation techniques. Resonances in the entire room are reduced, although the microphone array and secondary sources are confined to a small region close to the reflecting wall. Unlike previous control methods based on the creation of a plane wave sound field, the investigated method works in arbitrary room geometries and primary source positions.
Kastelein, Ronald A; van Heerden, Dorianne; Gransier, Robin; Hoek, Lean
2013-12-01
The high under-water sound pressure levels (SPLs) produced during pile driving to build offshore wind turbines may affect harbor porpoises. To estimate the discomfort threshold of pile driving sounds, a porpoise in a quiet pool was exposed to playbacks (46 strikes/min) at five SPLs (6 dB steps: 130-154 dB re 1 μPa). The spectrum of the impulsive sound resembled the spectrum of pile driving sound at tens of kilometers from the pile driving location in shallow water such as that found in the North Sea. The animal's behavior during test and baseline periods was compared. At and above a received broadband SPL of 136 dB re 1 μPa [zero-peak sound pressure level: 151 dB re 1 μPa; t90: 126 ms; sound exposure level of a single strike (SELss): 127 dB re 1 μPa(2) s] the porpoise's respiration rate increased in response to the pile driving sounds. At higher levels, he also jumped out of the water more often. Wild porpoises are expected to move tens of kilometers away from offshore pile driving locations; response distances will vary with context, the sounds' source level, parameters influencing sound propagation, and background noise levels. Copyright © 2013 Elsevier Ltd. All rights reserved.
Aspiring to Spectral Ignorance in Earth Observation
NASA Astrophysics Data System (ADS)
Oliver, S. A.
2016-12-01
Enabling robust, defensible and integrated decision making in the Era of Big Earth Data requires the fusion of data from multiple and diverse sensor platforms and networks. While the application of standardised global grid systems provides a common spatial analytics framework that facilitates the computationally efficient and statistically valid integration and analysis of these various data sources across multiple scales, there remains the challenge of sensor equivalency; particularly when combining data from different earth observation satellite sensors (e.g. combining Landsat and Sentinel-2 observations). To realise the vision of a sensor ignorant analytics platform for earth observation we require automation of spectral matching across the available sensors. Ultimately, the aim is to remove the requirement for the user to possess any sensor knowledge in order to undertake analysis. This paper introduces the concept of spectral equivalence and proposes a methodology through which equivalent bands may be sourced from a set of potential target sensors through application of equivalence metrics and thresholds. A number of parameters can be used to determine whether a pair of spectra are equivalent for the purposes of analysis. A baseline set of thresholds for these parameters and how to apply them systematically to enable relation of spectral bands amongst numerous different sensors is proposed. The base unit for comparison in this work is the relative spectral response. From this input, determination of a what may constitute equivalence can be related by a user, based on their own conceptualisation of equivalence.
Determination of equivalent sound speed profiles for ray tracing in near-ground sound propagation.
Prospathopoulos, John M; Voutsinas, Spyros G
2007-09-01
The determination of appropriate sound speed profiles in the modeling of near-ground propagation using a ray tracing method is investigated using a ray tracing model which is capable of performing axisymmetric calculations of the sound field around an isolated source. Eigenrays are traced using an iterative procedure which integrates the trajectory equations for each ray launched from the source at a specific direction. The calculation of sound energy losses is made by introducing appropriate coefficients to the equations representing the effect of ground and atmospheric absorption and the interaction with the atmospheric turbulence. The model is validated against analytical and numerical predictions of other methodologies for simple cases, as well as against measurements for nonrefractive atmospheric environments. A systematic investigation for near-ground propagation in downward and upward refractive atmosphere is made using experimental data. Guidelines for the suitable simulation of the wind velocity profile are derived by correlating predictions with measurements.
Sound absorption of a finite micro-perforated panel backed by a shunted loudspeaker.
Tao, Jiancheng; Jing, Ruixiang; Qiu, Xiaojun
2014-01-01
Deep back cavities are usually required for micro-perforated panel (MPP) constructions to achieve good low frequency absorption. To overcome the problem, a close-box loudspeaker with a shunted circuit is proposed to substitute the back wall of the cavity of the MPP constructions to constitute a composite absorber. Based on the equivalent circuit model, the acoustic impedance of the shunted loudspeaker is formulated first, then a prediction model of the sound absorption of the MPP backed by shunted loudspeaker is developed by employing the mode solution of a finite size MPP coupled by an air cavity with an impendence back wall. The MPP absorbs mid to high frequency sound, and with properly adjusted electrical parameters of its shunted circuit, the shunted loudspeaker absorbs low frequency sound, so the composite absorber provides a compact solution to broadband sound control. Numerical simulations and experiments are carried out to validate the model.
Wind turbine sound pressure level calculations at dwellings.
Keith, Stephen E; Feder, Katya; Voicescu, Sonia A; Soukhovtsev, Victor; Denning, Allison; Tsang, Jason; Broner, Norm; Leroux, Tony; Richarz, Werner; van den Berg, Frits
2016-03-01
This paper provides calculations of outdoor sound pressure levels (SPLs) at dwellings for 10 wind turbine models, to support Health Canada's Community Noise and Health Study. Manufacturer supplied and measured wind turbine sound power levels were used to calculate outdoor SPL at 1238 dwellings using ISO [(1996). ISO 9613-2-Acoustics] and a Swedish noise propagation method. Both methods yielded statistically equivalent results. The A- and C-weighted results were highly correlated over the 1238 dwellings (Pearson's linear correlation coefficient r > 0.8). Calculated wind turbine SPLs were compared to ambient SPLs from other sources, estimated using guidance documents from the United States and Alberta, Canada.
NASA Astrophysics Data System (ADS)
Naghibolhosseini, Maryam
Our ability to hear depends primarily on sound waves traveling through the outer and middle ear toward the inner ear. Hence, the characteristics of the outer and middle ear affect sound transmission to/from the inner ear. The role of the middle and outer ear in sound transmission is particularly important for otoacoustic emissions (OAEs), which are sound signals generated in a healthy cochlea, and recorded by a sensitive microphone placed in the ear canal. OAEs are used to evaluate the health and function of the cochlea; however, they are also affected by outer and middle ear characteristics. To better assess cochlear health using OAEs, it is critical to quantify the impact of the outer and middle ear on sound transmission. The reported research introduces a noninvasive approach to estimate outer-middle ear transmission using distortion product otoacoustic emissions (DPOAEs). In addition, the role of the outer and middle ear on sound transmission was investigated by developing a physical/mathematical model, which employed fractional-order lumped elements to include the viscoelastic characteristics of biological tissues. Impedance estimations from wideband refectance measurements were used for parameter fitting of the model. The model was validated comparing its estimates of the outer-middle ear sound transmission with those given by DPOAEs. The outer-middle ear transmission by the model was defined as the sum of forward and reverse outer-middle ear transmissions. To estimate the reverse transmission by the model, the probe-microphone impedance was calculated through estimating the Thevenin-equivalent circuit of the probe-microphone. The Thevenin-equivalent circuit was calculated using measurements in a number of test cavities. Such modeling enhances our understanding of the roles of different parts of the outer and middle ear and how they work together to determine their function. In addition, the model would be potentially helpful in diagnosing pathologies of cochlear or middle ear origin.
NASA Astrophysics Data System (ADS)
Wang, Xuejuan; Wu, Shuhang; Liu, Yunpeng
2018-04-01
This paper presents a new method for wood defect detection. It can solve the over-segmentation problem existing in local threshold segmentation methods. This method effectively takes advantages of visual saliency and local threshold segmentation. Firstly, defect areas are coarsely located by using spectral residual method to calculate global visual saliency of them. Then, the threshold segmentation of maximum inter-class variance method is adopted for positioning and segmenting the wood surface defects precisely around the coarse located areas. Lastly, we use mathematical morphology to process the binary images after segmentation, which reduces the noise and small false objects. Experiments on test images of insect hole, dead knot and sound knot show that the method we proposed obtains ideal segmentation results and is superior to the existing segmentation methods based on edge detection, OSTU and threshold segmentation.
DOT National Transportation Integrated Search
1971-01-01
The displacement of a threshold from its measured-in-the-quiet value to the value it takes in the presence of another sound is masking. Measurement of that displacement is masking audiometry. And the measurement of displacements at a large number of ...
Finneran, James J; Houser, Dorian S
2006-05-01
Traditional behavioral techniques for hearing assessment in marine mammals are limited by the time and access required to train subjects. Electrophysiological methods, where passive electrodes are used to measure auditory evoked potentials (AEPs), are attractive alternatives to behavioral techniques; however, there have been few attempts to compare AEP and behavioral results for the same subject. In this study, behavioral and AEP hearing thresholds were compared in four bottlenose dolphins. AEP thresholds were measured in-air using a piezoelectric sound projector embedded in a suction cup to deliver amplitude modulated tones to the dolphin through the lower jaw. Evoked potentials were recorded noninvasively using surface electrodes. Adaptive procedures allowed AEP hearing thresholds to be estimated from 10 to 150 kHz in a single ear in about 45 min. Behavioral thresholds were measured in a quiet pool and in San Diego Bay. AEP and behavioral threshold estimates agreed closely as to the upper cutoff frequency beyond which thresholds increased sharply. AEP thresholds were strongly correlated with pool behavioral thresholds across the range of hearing; differences between AEP and pool behavioral thresholds increased with threshold magnitude and ranged from 0 to + 18 dB.
Cochlear pathology in chronic suppurative otitis media.
Walby, A P; Barrera, A; Schuknecht, H F
1983-01-01
Chronic suppurative otitis media (COM) is reported to cause elevation of bone-conduction thresholds either by damage to cochlear sensorineural structures or by alteration in the mechanics of sound transmission in the ear. A retrospective study was made of the medical records of 87 patients with unilateral uncomplicated COM to document that abnormality in bone conduction does exist. In a separate study the cochlear pathology in 12 pairs of temporal bones with unilateral COM was studied by light microscopy. Infected ears showed higher than normal mean bone-conduction thresholds by amounts ranging from 1 dB at 500 Hz to 9.5 dB at 4,000 Hz. The temporal bones showed no greater loss of specialized sensorineural structures in infected ears than in normal control ears. Because there is no evidence that COM caused destruction of hair cells or cochlear neurons, alteration in the mechanics of sound transmission becomes a more plausible explanation for the hearing losses.
Noise-induced hearing impairment and handicap
NASA Technical Reports Server (NTRS)
1984-01-01
A permanent, noise-induced hearing loss has doubly harmful effect on speech communications. First, the elevation in the threshold of hearing means that many speech sounds are too weak to be heard, and second, very intense speech sounds may appear to be distorted. The whole question of the impact of noise-induced hearing loss upon the impairments and handicaps experienced by people with such hearing losses was somewhat controversial partly because of the economic aspects of related practical noise control and workmen's compensation.
Getting the cocktail party started: masking effects in speech perception
Evans, S; McGettigan, C; Agnew, ZK; Rosen, S; Scott, SK
2016-01-01
Spoken conversations typically take place in noisy environments and different kinds of masking sounds place differing demands on cognitive resources. Previous studies, examining the modulation of neural activity associated with the properties of competing sounds, have shown that additional speech streams engage the superior temporal gyrus. However, the absence of a condition in which target speech was heard without additional masking made it difficult to identify brain networks specific to masking and to ascertain the extent to which competing speech was processed equivalently to target speech. In this study, we scanned young healthy adults with continuous functional Magnetic Resonance Imaging (fMRI), whilst they listened to stories masked by sounds that differed in their similarity to speech. We show that auditory attention and control networks are activated during attentive listening to masked speech in the absence of an overt behavioural task. We demonstrate that competing speech is processed predominantly in the left hemisphere within the same pathway as target speech but is not treated equivalently within that stream, and that individuals who perform better in speech in noise tasks activate the left mid-posterior superior temporal gyrus more. Finally, we identify neural responses associated with the onset of sounds in the auditory environment, activity was found within right lateralised frontal regions consistent with a phasic alerting response. Taken together, these results provide a comprehensive account of the neural processes involved in listening in noise. PMID:26696297
DETECTION AND IDENTIFICATION OF SPEECH SOUNDS USING CORTICAL ACTIVITY PATTERNS
Centanni, T.M.; Sloan, A.M.; Reed, A.C.; Engineer, C.T.; Rennaker, R.; Kilgard, M.P.
2014-01-01
We have developed a classifier capable of locating and identifying speech sounds using activity from rat auditory cortex with an accuracy equivalent to behavioral performance without the need to specify the onset time of the speech sounds. This classifier can identify speech sounds from a large speech set within 40 ms of stimulus presentation. To compare the temporal limits of the classifier to behavior, we developed a novel task that requires rats to identify individual consonant sounds from a stream of distracter consonants. The classifier successfully predicted the ability of rats to accurately identify speech sounds for syllable presentation rates up to 10 syllables per second (up to 17.9 ± 1.5 bits/sec), which is comparable to human performance. Our results demonstrate that the spatiotemporal patterns generated in primary auditory cortex can be used to quickly and accurately identify consonant sounds from a continuous speech stream without prior knowledge of the stimulus onset times. Improved understanding of the neural mechanisms that support robust speech processing in difficult listening conditions could improve the identification and treatment of a variety of speech processing disorders. PMID:24286757
A Visit with Mildred Milliea of Big Cove, New Brunswick
ERIC Educational Resources Information Center
Gray, Viviane
1976-01-01
Mildred Milliea has researched and developed the only Micmac language program in the Maritimes. The Micmac alphabet with equivalent sounds, the numerical system, and examples of new Micmac words are given. (NQ)
Loudness function derives from data on electrical discharge rates in auditory nerve fibers
NASA Technical Reports Server (NTRS)
Howes, W. L.
1973-01-01
Judgements of the loudness of pure-tone sound stimuli yield a loudness function which relates perceived loudness to stimulus amplitude. A loudness function is derived from physical evidence alone without regard to human judgments. The resultant loudness function is L=K(q-q0), where L is loudness, q is effective sound pressure (specifically q0 at the loudness threshold), and K is generally a weak function of the number of stimulated auditory nerve fibers. The predicted function is in agreement with loudness judgment data reported by Warren, which imply that, in the suprathreshold loudness regime, decreasing the sound-pressure level by 6 db results in halving the loudness.
Effects of modulation phase on profile analysis in normal-hearing and hearing-impaired listeners
NASA Astrophysics Data System (ADS)
Rogers, Deanna; Lentz, Jennifer
2003-04-01
The ability to discriminate between sounds with different spectral shapes in the presence of amplitude modulation was measured in normal-hearing and hearing-impaired listeners. The standard stimulus was the sum of equal-amplitude modulated tones, and the signal stimulus was generated by increasing the level of half the tones (up components) and decreasing the level of half the tones (down components). The down components had the same modulation phase, and a phase shift was applied to the up components to encourage segregation from the down tones. The same phase shift was used in both standard and signal stimuli. Profile-analysis thresholds were measured as a function of the phase shift between up and down components. The phase shifts were 0, 30, 45, 60, 90, and 180 deg. As expected, thresholds were lowest when all tones had the same modulation phase and increased somewhat with increasing phase disparity. This small increase in thresholds was similar for both groups. These results suggest that hearing-impaired listeners are able to use modulation phase to group sounds in a manner similar to that of normal listeners. [Work supported by NIH (DC 05835).
Davidson, Lisa S; Skinner, Margaret W; Holstad, Beth A; Fears, Beverly T; Richter, Marie K; Matusofsky, Margaret; Brenner, Christine; Holden, Timothy; Birath, Amy; Kettel, Jerrica L; Scollie, Susan
2009-06-01
The purpose of this study was to examine the effects of a wider instantaneous input dynamic range (IIDR) setting on speech perception and comfort in quiet and noise for children wearing the Nucleus 24 implant system and the Freedom speech processor. In addition, children's ability to understand soft and conversational level speech in relation to aided sound-field thresholds was examined. Thirty children (age, 7 to 17 years) with the Nucleus 24 cochlear implant system and the Freedom speech processor with two different IIDR settings (30 versus 40 dB) were tested on the Consonant Nucleus Consonant (CNC) word test at 50 and 60 dB SPL, the Bamford-Kowal-Bench Speech in Noise Test, and a loudness rating task for four-talker speech noise. Aided thresholds for frequency-modulated tones, narrowband noise, and recorded Ling sounds were obtained with the two IIDRs and examined in relation to CNC scores at 50 dB SPL. Speech Intelligibility Indices were calculated using the long-term average speech spectrum of the CNC words at 50 dB SPL measured at each test site and aided thresholds. Group mean CNC scores at 50 dB SPL with the 40 IIDR were significantly higher (p < 0.001) than with the 30 IIDR. Group mean CNC scores at 60 dB SPL, loudness ratings, and the signal to noise ratios-50 for Bamford-Kowal-Bench Speech in Noise Test were not significantly different for the two IIDRs. Significantly improved aided thresholds at 250 to 6000 Hz as well as higher Speech Intelligibility Indices afforded improved audibility for speech presented at soft levels (50 dB SPL). These results indicate that an increased IIDR provides improved word recognition for soft levels of speech without compromising comfort of higher levels of speech sounds or sentence recognition in noise.
Audiovisual Delay as a Novel Cue to Visual Distance.
Jaekl, Philip; Seidlitz, Jakob; Harris, Laurence R; Tadin, Duje
2015-01-01
For audiovisual sensory events, sound arrives with a delay relative to light that increases with event distance. It is unknown, however, whether humans can use these ubiquitous sound delays as an information source for distance computation. Here, we tested the hypothesis that audiovisual delays can both bias and improve human perceptual distance discrimination, such that visual stimuli paired with auditory delays are perceived as more distant and are thereby an ordinal distance cue. In two experiments, participants judged the relative distance of two repetitively displayed three-dimensional dot clusters, both presented with sounds of varying delays. In the first experiment, dot clusters presented with a sound delay were judged to be more distant than dot clusters paired with equivalent sound leads. In the second experiment, we confirmed that the presence of a sound delay was sufficient to cause stimuli to appear as more distant. Additionally, we found that ecologically congruent pairing of more distant events with a sound delay resulted in an increase in the precision of distance judgments. A control experiment determined that the sound delay duration influencing these distance judgments was not detectable, thereby eliminating decision-level influence. In sum, we present evidence that audiovisual delays can be an ordinal cue to visual distance.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-02
...'' sections). Low-frequency signals of the Acoustic Thermometry of Ocean Climate sound source were not found...). Factors that influence the amount of threshold shift include the amplitude, duration, frequency content...
Graham, Christine E.; Vetter, Douglas E.
2011-01-01
Cells of the inner ear face constant metabolic and structural stress. Exposure to intense sound or certain drugs destroys cochlea hair cells, which in mammals do not regenerate. Thus, an endogenous stress response system may exist within the cochlea to protect it from everyday stressors. We recently described the existence of Corticotropin-Releasing Factor (CRF) in the mouse cochlea. The CRFR1 receptor is considered the primary and canonical target of CRF signaling, and systemically it plays an essential role in coordinating the body-wide stress response via activation of the hypothalamic-pituitary-adrenal (HPA) axis. Here we describe an essential role for CRFR1 in auditory system development and function, and offer the first description of a complete HPA equivalent signaling system resident within the cochlea. To reveal the role of CRFR1 activation in the cochlea, we have used mice carrying a null ablation of the CRFR1 gene. CRFR1−/− mice exhibited elevated auditory thresholds at all frequencies tested, indicating reduced sensitivity. Furthermore, our results suggest that CRFR1 has a developmental role affecting inner hair cell morphology and afferent and efferent synapse distribution. Given the role of HPA signaling in maintaining local homeostasis in other tissues, the presence of a cochlear HPA signaling system suggests important roles for CRFR1 activity in setting cochlear sensitivity, perhaps both neural and non-neural mechanisms. These data highlight the complex pleiotropic mechanisms modulated by CRFR1 signaling in the cochlea. PMID:21273411
Hearing gain with a BAHA test-band in patients with single-sided deafness.
Kim, Do-Youn; Kim, Tae Su; Shim, Byoung Soo; Jin, In Suk; Ahn, Joong Ho; Chung, Jong Woo; Yoon, Tae Hyun; Park, Hong Ju
2014-01-01
It is assumed that preoperative use of a bone-anchored hearing aid (BAHA) test-band will give a patient lower gain compared to real post-operative gain because of the reduction of energy through the scalp when using a test-band. Hearing gains using a BAHA test-band were analyzed in patients with unilateral hearing loss. Nineteen patients with unilateral sensorineural hearing loss were enrolled. A test-band, which was connected to BAHA Intenso with full-on gain, was put on the mastoid. Conventional air-conduction (AC) pure-tone averages (PTAs) and sound-field PTAs and speech reception thresholds (SRTs) were obtained in conditions A (the better ear naked), B (the better ear plugged), and C (the better ear plugged with a test-band on the poorer mastoid). Air-conduction PTAs of the poorer and better ears were 91 ± 19 and 18 ± 8 dB HL. Sound-field PTAs in condition B were higher than those in condition A (54 vs. 26 dB HL), which means that earplugs can block the sound grossly up to 54 dB HL through the better ears. The aided PTAs (24 ± 6 dB HL) in condition C were similar to those of the better ears in condition A (26±9 dB HL), though condition C showed higher thresholds at 500 Hz and lower thresholds at 1 and 2kHz when compared to condition A. The hearing thresholds using a test-band were similar to the published results of BAHA users with the volume to most comfortable level (MCL). Our findings showed that a BAHA test-band on the poorer ear could transmit sound to the cochlea as much as the better ears can hear. The increased functional gain at 1 and 2kHz reflects the technical characteristics of BAHA processor. The reduction of energy through the scalp when using a test-band seems to be offset by the difference of output by setting the volume to full-on gain and using a high-powered speech processor. Preoperative hearing gains using a test-band with full-on gain seems to be similar to the post-operative gains of BAHA users with the volume to MCL. © 2013.
Contralateral Dpoae Suppression in Humans at Very Low Sound Intensities
NASA Astrophysics Data System (ADS)
Janssen, T.; Gehr, D. D.; Kevanishvili, Z.
2003-02-01
Different functions are attributed to the olivo-cochlear bundle system (OCBS) such as protecting the ear from acoustic injury, improving signal detection in noise, and mediating selective attention. OCBS reflex strength can be evaluated, in animals as well as in humans, by measuring the degree of suppression of an ipsilateral DPOAE by a contralateral sound. The purpose of the study was to evaluate OCBS reflex strength depending on ipsilateral stimulus level, especially at threshold, by means of extrapolated DPOAE I/O-functions. Additionally, DPOAE was measured at near-to-threshold contralateral stimulus levels when using low-level ipsilateral stimulation for investigating possible enhancement of outer hair cell motion in the presence of low-level contralateral sound. The recording of the 2f1-f2 DPOAE in the presence or absence of contralateral sound was performed in normally hearing human subjects at f2 = 2 kHz. DPOAE I/O-functions were measured in a primary tone level range from L2 = 20 to L2 = 65 dB SPL (L1 = 0.4L2 + 39, f2/f1=1.2). Broad-band noise (BBN), narrow-band noise from 1720 to 2320 Hz (NBN), and pure tones (PT) at f2, 2f1-f2, geometric mean of f1 and f2, and 0.1oct + f2 were used for contralateral stimulation. The contralateral stimulus level (Ls) was decreased from 70 down to 10 dB SPL in 10 dB steps. DPOAE suppression was highest at the lowest primary tone level and was more pronounced for BBN and NBN than for pure tones, suggesting a more diffuse than a strong tonotopic organisation of the OCBS. The contralateral stimulus level at which significant DPOAE suppression occurred (p < 0.05) was different for the different stimuli being 20, 40, and 70 dB SPL for BBN, NBN, and pure-tone (f2), respectively. Significant DPOAE suppression to BBN and NBN occurred at Ls well below audiological middle-ear reflex threshold. DPOAE time course was different for Ls below and above middle-ear reflex threshold. Thus, middle-ear muscle contraction is suggested not to be involved in DPOAE suppression at low Ls. No enhancement of DPOAE could be found. The findings suggest the OCBS to be functioning in a more protective way than for improving signal detection in noise.
Statistical Analysis for Subjective and Objective Evaluations of Dental Drill Sounds.
Yamada, Tomomi; Kuwano, Sonoko; Ebisu, Shigeyuki; Hayashi, Mikako
2016-01-01
The sound produced by a dental air turbine handpiece (dental drill) can markedly influence the sound environment in a dental clinic. Indeed, many patients report that the sound of a dental drill elicits an unpleasant feeling. Although several manufacturers have attempted to reduce the sound pressure levels produced by dental drills during idling based on ISO 14457, the sound emitted by such drills under active drilling conditions may negatively influence the dental clinic sound environment. The physical metrics related to the unpleasant impressions associated with dental drill sounds have not been determined. In the present study, psychological measurements of dental drill sounds were conducted with the aim of facilitating improvement of the sound environment at dental clinics. Specifically, we examined the impressions elicited by the sounds of 12 types of dental drills in idling and drilling conditions using a semantic differential. The analysis revealed that the impressions of dental drill sounds varied considerably between idling and drilling conditions and among the examined drills. This finding suggests that measuring the sound of a dental drill in idling conditions alone may be insufficient for evaluating the effects of the sound. We related the results of the psychological evaluations to those of measurements of the physical metrics of equivalent continuous A-weighted sound pressure levels (LAeq) and sharpness. Factor analysis indicated that impressions of the dental drill sounds consisted of two factors: "metallic and unpleasant" and "powerful". LAeq had a strong relationship with "powerful impression", calculated sharpness was positively related to "metallic impression", and "unpleasant impression" was predicted by the combination of both LAeq and calculated sharpness. The present analyses indicate that, in addition to a reduction in sound pressure level, refining the frequency components of dental drill sounds is important for creating a comfortable sound environment in dental clinics.
Wysocki, L.E.; Davidson, J. W.; Smith, M.E.; Frankel, A.S.; Ellison, W.T.; Mazik, P.M.; Popper, A.N.; Bebak, J.
2007-01-01
Intensive aquaculture production often utilizes equipment (e.g., aerators, air and water pumps, harvesters, blowers, filtration systems, and maintenance machinery) that increases noise levels in fish culture tanks. Consequently, chronic exposure to elevated noise levels in tanks could negatively impact cultured species. Possible effects include impairment of the auditory system, increased stress, and reduced growth rates. The objective of this study was to evaluate the long-term effects of sound exposure on the hearing sensitivity, growth, and survival of cultured rainbow trout (Oncorhynchus mykiss). Two cohorts of rainbow trout were cultured for 8??months in replicated tanks consisting of three sound treatments: 115, 130, or 150 decibels referenced at 1 micropascal (dB re 1????Pa root mean square [RMS]) levels. Auditory evoked potential (AEP) recordings revealed no significant differences in hearing thresholds resulting from exposure to increased ambient sound levels. Although there was no evident noise-induced hearing loss, there were significant differences in hearing thresholds between the two fish cohorts examined. No statistical effect of sound treatment was found for growth rate and mortality within each fish cohort. There was no significant difference in mortality between sound treatments when fish were exposed to the pathogen Yersinia ruckeri, but there was significantly different mortality between cohorts. This study indicated that rainbow trout hearing sensitivity, growth, survival, stress, and disease susceptibility were not negatively impacted by noise levels common to recirculating aquaculture systems. These findings should not be generalized to all cultured fish species, however, because many species, including catfish and cyprinids, have much greater hearing sensitivity than rainbow trout and could be affected differently by noise. ?? 2007 Elsevier B.V. All rights reserved.
Optimal wavelet denoising for smart biomonitor systems
NASA Astrophysics Data System (ADS)
Messer, Sheila R.; Agzarian, John; Abbott, Derek
2001-03-01
Future smart-systems promise many benefits for biomedical diagnostics. The ideal is for simple portable systems that display and interpret information from smart integrated probes or MEMS-based devices. In this paper, we will discuss a step towards this vision with a heart bio-monitor case study. An electronic stethoscope is used to record heart sounds and the problem of extracting noise from the signal is addressed via the use of wavelets and averaging. In our example of heartbeat analysis, phonocardiograms (PCGs) have many advantages in that they may be replayed and analysed for spectral and frequency information. Many sources of noise may pollute a PCG including foetal breath sounds if the subject is pregnant, lung and breath sounds, environmental noise and noise from contact between the recording device and the skin. Wavelets can be employed to denoise the PCG. The signal is decomposed by a discrete wavelet transform. Due to the efficient decomposition of heart signals, their wavelet coefficients tend to be much larger than those due to noise. Thus, coefficients below a certain level are regarded as noise and are thresholded out. The signal can then be reconstructed without significant loss of information in the signal. The questions that this study attempts to answer are which wavelet families, levels of decomposition, and thresholding techniques best remove the noise in a PCG. The use of averaging in combination with wavelet denoising is also addressed. Possible applications of the Hilbert Transform to heart sound analysis are discussed.
There's a Green Glob in Your Classroom.
ERIC Educational Resources Information Center
Dugdale, Sharon
1983-01-01
Discusses computer games (called intrinsic models) focusing on mathematics rather than on unrelated motivations (flashing lights or sounds). Games include "Green Globs," (equations/linear functions), "Darts"/"Torpedo" (fractions), "Escape" (graphing), and "Make-a-Monster" (equivalent fractions and…
Structured Counseling for Auditory Dynamic Range Expansion.
Gold, Susan L; Formby, Craig
2017-02-01
A structured counseling protocol is described that, when combined with low-level broadband sound therapy from bilateral sound generators, offers audiologists a new tool for facilitating the expansion of the auditory dynamic range (DR) for loudness. The protocol and its content are specifically designed to address and treat problems that impact hearing-impaired persons who, due to their reduced DRs, may be limited in the use and benefit of amplified sound from hearing aids. The reduced DRs may result from elevated audiometric thresholds and/or reduced sound tolerance as documented by lower-than-normal loudness discomfort levels (LDLs). Accordingly, the counseling protocol is appropriate for challenging and difficult-to-fit persons with sensorineural hearing losses who experience loudness recruitment or hyperacusis. Positive treatment outcomes for individuals with the former and latter conditions are highlighted in this issue by incremental shifts (improvements) in LDL and/or categorical loudness judgments, associated reduced complaints of sound intolerance, and functional improvements in daily communication, speech understanding, and quality of life leading to improved hearing aid benefit, satisfaction, and aided sound quality, posttreatment.
Structured Counseling for Auditory Dynamic Range Expansion
Gold, Susan L.; Formby, Craig
2017-01-01
A structured counseling protocol is described that, when combined with low-level broadband sound therapy from bilateral sound generators, offers audiologists a new tool for facilitating the expansion of the auditory dynamic range (DR) for loudness. The protocol and its content are specifically designed to address and treat problems that impact hearing-impaired persons who, due to their reduced DRs, may be limited in the use and benefit of amplified sound from hearing aids. The reduced DRs may result from elevated audiometric thresholds and/or reduced sound tolerance as documented by lower-than-normal loudness discomfort levels (LDLs). Accordingly, the counseling protocol is appropriate for challenging and difficult-to-fit persons with sensorineural hearing losses who experience loudness recruitment or hyperacusis. Positive treatment outcomes for individuals with the former and latter conditions are highlighted in this issue by incremental shifts (improvements) in LDL and/or categorical loudness judgments, associated reduced complaints of sound intolerance, and functional improvements in daily communication, speech understanding, and quality of life leading to improved hearing aid benefit, satisfaction, and aided sound quality, posttreatment. PMID:28286367
Experimental Evaluation of Equivalent-Fluid Models for Melamine Foam
NASA Technical Reports Server (NTRS)
Allen, Albert R.; Schiller, Noah H.
2016-01-01
Melamine foam is a soft porous material commonly used in noise control applications. Many models exist to represent porous materials at various levels of fidelity. This work focuses on rigid frame equivalent fluid models, which represent the foam as a fluid with a complex speed of sound and density. There are several empirical models available to determine these frequency dependent parameters based on an estimate of the material flow resistivity. Alternatively, these properties can be experimentally educed using an impedance tube setup. Since vibroacoustic models are generally sensitive to these properties, this paper assesses the accuracy of several empirical models relative to impedance tube measurements collected with melamine foam samples. Diffuse field sound absorption measurements collected using large test articles in a laboratory are also compared with absorption predictions determined using model-based and measured foam properties. Melamine foam slabs of various thicknesses are considered.
Searchfield, Grant D; Linford, Tania; Kobayashi, Kei; Crowhen, David; Latzel, Matthias
2018-03-01
To compare preference for and performance of manually selected programmes to an automatic sound classifier, the Phonak AutoSense OS. A single blind repeated measures study. Participants were fit with Phonak Virto V90 ITE aids; preferences for different listening programmes were compared across four different sound scenarios (speech in: quiet, noise, loud noise and a car). Following a 4-week trial preferences were reassessed and the users preferred programme was compared to the automatic classifier for sound quality and hearing in noise (HINT test) using a 12 loudspeaker array. Twenty-five participants with symmetrical moderate-severe sensorineural hearing loss. Participant preferences of manual programme for scenarios varied considerably between and within sessions. A HINT Speech Reception Threshold (SRT) advantage was observed for the automatic classifier over participant's manual selection for speech in quiet, loud noise and car noise. Sound quality ratings were similar for both manual and automatic selections. The use of a sound classifier is a viable alternative to manual programme selection.
A procedure for the reliability improvement of the oblique ionograms automatic scaling algorithm
NASA Astrophysics Data System (ADS)
Ippolito, Alessandro; Scotto, Carlo; Sabbagh, Dario; Sgrigna, Vittorio; Maher, Phillip
2016-05-01
A procedure made by the combined use of the Oblique Ionogram Automatic Scaling Algorithm (OIASA) and Autoscala program is presented. Using Martyn's equivalent path theorem, 384 oblique soundings from a high-quality data set have been converted into vertical ionograms and analyzed by Autoscala program. The ionograms pertain to the radio link between Curtin W.A. (CUR) and Alice Springs N.T. (MTE), Australia, geographical coordinates (17.60°S; 123.82°E) and (23.52°S; 133.68°E), respectively. The critical frequency foF2 values extracted from the converted vertical ionograms by Autoscala were then compared with the foF2 values derived from the maximum usable frequencies (MUFs) provided by OIASA. A quality factor Q for the MUF values autoscaled by OIASA has been identified. Q represents the difference between the foF2 value scaled by Autoscala from the converted vertical ionogram and the foF2 value obtained applying the secant law to the MUF provided by OIASA. Using the receiver operating characteristic curve, an appropriate threshold level Qt was chosen for Q to improve the performance of OIASA.
Vortex Noise from Rotating Cylindrical Rods
NASA Technical Reports Server (NTRS)
Stowell, E Z; Deming, A F
1935-01-01
A series of round rods of the some diameter were rotated individually about the mid-point of each rod. Vortices are shed from the rods when in motion, giving rise to the emission of sound. With the rotating system placed in the open air, the distribution of sound in space, the acoustical power output, and the spectral distribution have been studied. The frequency of emission of vortices from any point on the rod is given by the formula von Karman. From the spectrum estimates are made of the distribution of acoustical power along the rod, the amount of air concerned in sound production, the "equivalent size" of the vortices, and the acoustical energy content for each vortex.
Wang, Ningqian; Wang, Xiao; Yang, Xiaoli; Tang, Jie; Xiao, Zhongju
2014-01-16
In this study, we adopted iso-frequency pure tone bursts to investigate the interdependent effects of sound amplitude/intensity and duration on mice inferior colliculus (IC) neuronal onset responses. On the majority of the sampled neurons (n=57, 89.1%), sound amplitude and duration had effects on the neuronal response to each other by showing complex changes of the rat-intensity function/duration selectivity types and/or best amplitudes (BAs)/durations (BDs), evaluated by spike counts. These results suggested that the balance between the excitatory and inhibitory inputs set by one acoustic parameter, amplitude or duration, affected the neuronal spike counts responses to the other. Neuronal duration selectivity types were altered easily by the low-amplitude sounds while the changes of rate-intensity function types had no obvious preferred stimulus durations. However, the first spike latencies (FSLs) of the onset response neurons were relative stable to iso-amplitude sound durations and changing systematically along with the sound levels. The superimposition of FSL and duration threshold (DT) as a function of stimulus amplitude after normalization indicated that the effects of the sound levels on FSLs are considered on DT actually. © 2013 Published by Elsevier B.V.
Jotterand, Fabrice; Wangmo, Tenzin
2014-01-01
In this article we critically examine the principle of equivalence of care in prison medicine. First, we provide an overview of how the principle of equivalence is utilized in various national and international guidelines on health care provision to prisoners. Second, we outline some of the problems associated with its applications, and argue that the principle of equivalence should go beyond equivalence to access and include equivalence of outcomes. However, because of the particular context of the prison environment, third, we contend that the concept of "health" in equivalence of health outcomes needs conceptual clarity; otherwise, it fails to provide a threshold for healthy states among inmates. We accomplish this by examining common understandings of the concepts of health and disease. We conclude our article by showing why the conceptualization of diseases as clinical problems provides a helpful approach in the delivery of health care in prison.
Hearing in nonprofessional pop/rock musicians.
Schmuziger, Nicolas; Patscheke, Jochen; Probst, Rudolf
2006-08-01
The purpose of this study was to evaluate the hearing and subjective auditory symptoms in a group of nonprofessional pop/rock musicians who had experienced repeated exposures to intense sound levels during at least 5 yr of musical activity. An evaluation of both ears in 42 nonprofessional pop/rock musicians included pure-tone audiometry in the conventional and extended high-frequency range, the measurement of uncomfortable loudness levels, and an assessment of tinnitus and hypersensitivity to sound. Exclusion criteria were (a) the occurrence of acoustic trauma, (b) excessive noise exposure during occupational activities, (c) a history of recurrent otitis media, (d) previous ear surgery, (e) a fracture of the cranium, (f) ingestion of potentially ototoxic drugs, and (g) reported hearing difficulties within the immediate family. These audiometric results were then compared with a control group of 20 otologically normal young adults with no history of long-term noise exposure. After adjusting for age and gender, relative to ISO 7029, the mean hearing threshold in the frequency range of 3 to 8 kHz was 6 dB in the musicians and 1.5 dB in the control group. This difference was statistically significant (Mann-Whitney rank sum test, p < 0.001). A significant difference was also observed between musicians using regular hearing protection during their activities (average 3 to 8 kHz thresholds = 2.4 dB) and musicians who never used such hearing protection (average 3 to 8 kHz thresholds = 8.2 dB), after adjusting for age and gender (Mann-Whitney rank sum test, p = 0.006). Eleven of the musicians (26%) were found to be hypersensitive to sound, and seven (17%) presented with tinnitus. Tinnitus assessment, however, did not reveal any clinically significant psychological distress in these individuals. Tinnitus and hypersensitivity to sound were observed in a significant minority within a group of nonprofessional pop/rock musicians who had experienced repeated exposure to intense sound levels over at least 5 yr but with minimal impact on their lives. Moreover, hearing loss was minimal in the subjects who always used ear protection, being only 0.9 dB higher than the control group. In contrast, hearing loss was significantly more pronounced, at 6.7 dB higher than the control group, in those musicians who never used ear protection. Continued education about the risk to hearing and the benefits of the persistent use of ear protection is warranted for musicians who are exposed frequently to intense sound levels.
An experimental comparison of various methods of nearfield acoustic holography
Chelliah, Kanthasamy; Raman, Ganesh; Muehleisen, Ralph T.
2017-05-19
An experimental comparison of four different methods of nearfield acoustic holography (NAH) is presented in this study for planar acoustic sources. The four NAH methods considered in this study are based on: (1) spatial Fourier transform, (2) equivalent sources model, (3) boundary element methods and (4) statistically optimized NAH. Two dimensional measurements were obtained at different distances in front of a tonal sound source and the NAH methods were used to reconstruct the sound field at the source surface. Reconstructed particle velocity and acoustic pressure fields presented in this study showed that the equivalent sources model based algorithm along withmore » Tikhonov regularization provided the best localization of the sources. Reconstruction errors were found to be smaller for the equivalent sources model based algorithm and the statistically optimized NAH algorithm. Effect of hologram distance on the performance of various algorithms is discussed in detail. The study also compares the computational time required by each algorithm to complete the comparison. Four different regularization parameter choice methods were compared. The L-curve method provided more accurate reconstructions than the generalized cross validation and the Morozov discrepancy principle. Finally, the performance of fixed parameter regularization was comparable to that of the L-curve method.« less
An experimental comparison of various methods of nearfield acoustic holography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chelliah, Kanthasamy; Raman, Ganesh; Muehleisen, Ralph T.
An experimental comparison of four different methods of nearfield acoustic holography (NAH) is presented in this study for planar acoustic sources. The four NAH methods considered in this study are based on: (1) spatial Fourier transform, (2) equivalent sources model, (3) boundary element methods and (4) statistically optimized NAH. Two dimensional measurements were obtained at different distances in front of a tonal sound source and the NAH methods were used to reconstruct the sound field at the source surface. Reconstructed particle velocity and acoustic pressure fields presented in this study showed that the equivalent sources model based algorithm along withmore » Tikhonov regularization provided the best localization of the sources. Reconstruction errors were found to be smaller for the equivalent sources model based algorithm and the statistically optimized NAH algorithm. Effect of hologram distance on the performance of various algorithms is discussed in detail. The study also compares the computational time required by each algorithm to complete the comparison. Four different regularization parameter choice methods were compared. The L-curve method provided more accurate reconstructions than the generalized cross validation and the Morozov discrepancy principle. Finally, the performance of fixed parameter regularization was comparable to that of the L-curve method.« less
Jeanson, Lena; Wiegrebe, Lutz; Gürkov, Robert; Krause, Eike; Drexl, Markus
2017-02-01
The presentation of intense, low-frequency (LF) sound to the human ear can cause very slow, sinusoidal oscillations of cochlear sensitivity after LF sound offset, coined the "Bounce" phenomenon. Changes in level and frequency of spontaneous otoacoustic emissions (SOAEs) are a sensitive measure of the Bounce. Here, we investigated the effect of LF sound level and frequency on the Bounce. Specifically, the level of SOAEs was tracked for minutes before and after a 90-s LF sound exposure. Trials were carried out with several LF sound levels (93 to 108 dB SPL corresponding to 47 to 75 phons at a fixed frequency of 30 Hz) and different LF sound frequencies (30, 60, 120, 240 and 480 Hz at a fixed loudness level of 80 phons). At an LF sound frequency of 30 Hz, a minimal sound level of 102 dB SPL (64 phons) was sufficient to elicit a significant Bounce. In some subjects, however, 93 dB SPL (47 phons), the lowest level used, was sufficient to elicit the Bounce phenomenon and actual thresholds could have been even lower. Measurements with different LF sound frequencies showed a mild reduction of the Bounce phenomenon with increasing LF sound frequency. This indicates that the strength of the Bounce not only is a simple function of the spectral separation between SOAE and LF sound frequency but also depends on absolute LF sound frequency, possibly related to the magnitude of the AC component of the outer hair cell receptor potential.
NASA Astrophysics Data System (ADS)
Holland, Nicholas Vedder, III
Exposure to loud sounds is one of the leading causes of hearing loss in the United States. The purpose of the current research was to measure the sound pressure levels generated within a university concert band and determine if those levels exceeded permissible sound limits for exposure according to criteria set by the Occupational Safety and Health Administration (OSHA) and the National Institute of Occupational Safety and Health (NIOSH). Time-weighted averages (TWA) were obtained via a dosimeter during six rehearsals for nine members of the ensemble (plus the conductor), who were seated in frontal proximity to "instruments of power" (trumpets, trombones, and percussion; (Backus, 1977). Subjects received audiometer tests prior to and after each rehearsal to determine any temporary threshold shifts (TTS). Single sample t tests were calculated to compare TWA means and the maximum sound intensity exposures set by OSHA and NIOSH. Correlations were calculated between TWAs and TTSs, as well as TTSs and the number of semesters subjects reported being seated in proximity to instruments of power. The TWA-OSHA mean of 90.2 dBA was not significantly greater than the specified OSHA maximum standard of 90.0 dBA (p > .05). The TWA-NIOSH mean of 93.1 dBA was, however, significantly greater than the NIOSH specified maximum standard of 85.0 dBA (p < .05). The correlation between TWAs and TTSs was considered weak (r = .21 for OSHA, r = .20 for NIOSH); the correlation between TTSs and semesters of proximity to instruments of power was also considered weak (r = .13). TWAs cumulatively exceeded both association's sound exposure limits at 11 specified locations (nine subjects and both ears of the conductor) throughout the concert band's rehearsals. In addition, hearing acuity, as determined by TTSs, was substantially affected negatively by the intensities produced in the concert band. The researcher concluded that conductors, as well as their performers, must be aware of possible damaging sound intensities in rehearsals or performances.
The sound intensity and characteristics of variable-pitch pulse oximeters.
Yamanaka, Hiroo; Haruna, Junichi; Mashimo, Takashi; Akita, Takeshi; Kinouchi, Keiko
2008-06-01
Various studies worldwide have found that sound levels in hospitals significantly exceed the World Health Organization (WHO) guidelines, and that this noise is associated with audible signals from various medical devices. The pulse oximeter is now widely used in health care; however the health effects associated with the noise from this equipment remain largely unclarified. Here, we analyzed the sounds of variable-pitch pulse oximeters, and discussed the possible associated risk of sleep disturbance, annoyance, and hearing loss. The Nellcor N 595 and Masimo SET Radical pulse oximeters were measured for equivalent continuous A-weighted sound pressure levels (L(Aeq)), loudness levels, and loudness. Pulse beep pitches were also identified using Fast Fourier Transform (FFT) analysis and compared with musical pitches as controls. Almost all alarm sounds and pulse beeps from the instruments tested exceeded 30 dBA, a level that may induce sleep disturbance and annoyance. Several alarm sounds emitted by the pulse oximeters exceeded 70 dBA, which is known to induce hearing loss. The loudness of the alarm sound of each pulse oximeter did not change in proportion to the sound volume level. The pitch of each pulse beep did not correspond to musical pitch levels. The results indicate that sounds from pulse oximeters pose a potential risk of not only sleep disturbance and annoyance but also hearing loss, and that these sounds are unnatural for human auditory perception.
Knauert, Melissa; Jeon, Sangchoon; Murphy, Terrence E.; Yaggi, H. Klar; Pisani, Margaret A.; Redeker, Nancy S.
2016-01-01
Purpose Sound levels in the intensive care unit (ICU) are universally elevated and are believed to contribute to sleep and circadian disruption. The purpose of this study is to compare overnight ICU sound levels and peak occurrence on A- versus C-weighted scales. Materials and Methods This was a prospective observational study of overnight sound levels in 59 medical ICU patient rooms. Sound level was recorded every 10 seconds on A- and C-weighted decibel scales. Equivalent sound level (Leq) and sound peaks were reported for full and partial night periods. Results The overnight A-weighted Leq of 53.6 dBA was well above World Health Organization (WHO) recommendations; overnight C-weighted Leq was 63.1 dBC (no WHO recommendations). Peak sound occurrence ranged from 1.8 to 23.3 times per hour. Illness severity, mechanical ventilation and delirium were not associated with Leq or peak occurrence. Leq and peak measures for A- and C-weighted decibel scales were significantly different from each other. Conclusions Sound levels in the medical ICU are high throughout the night. Patient factors were not associated with Leq or peak occurrence. Significant discordance between A- and C-weighted values suggests that low frequency sound is a meaningful factor in the medical ICU environment. PMID:27546739
Quiet PROPELLER MRI techniques match the quality of conventional PROPELLER brain imaging techniques.
Corcuera-Solano, I; Doshi, A; Pawha, P S; Gui, D; Gaddipati, A; Tanenbaum, L
2015-06-01
Switching of magnetic field gradients is the primary source of acoustic noise in MR imaging. Sound pressure levels can run as high as 120 dB, capable of producing physical discomfort and at least temporary hearing loss, mandating hearing protection. New technology has made quieter techniques feasible, which range from as low as 80 dB to nearly silent. The purpose of this study was to evaluate the image quality of new commercially available quiet T2 and quiet FLAIR fast spin-echo PROPELLER acquisitions in comparison with equivalent conventional PROPELLER techniques in current day-to-day practice in imaging of the brain. Thirty-four consecutive patients were prospectively scanned with quiet T2 and quiet T2 FLAIR PROPELLER, in addition to spatial resolution-matched conventional T2 and T2 FLAIR PROPELLER imaging sequences on a clinical 1.5T MR imaging scanner. Measurement of sound pressure levels and qualitative evaluation of relative image quality was performed. Quiet T2 and quiet T2 FLAIR were comparable in image quality with conventional acquisitions, with sound levels of approximately 75 dB, a reduction in average sound pressure levels of up to 28.5 dB, with no significant trade-offs aside from longer scan times. Quiet FSE provides equivalent image quality at comfortable sound pressure levels at the cost of slightly longer scan times. The significant reduction in potentially injurious noise is particularly important in vulnerable populations such as children, the elderly, and the debilitated. Quiet techniques should be considered in these special situations for routine use in clinical practice. © 2015 by American Journal of Neuroradiology.
Monaural Sound Localization Based on Structure-Induced Acoustic Resonance
Kim, Keonwook; Kim, Youngwoong
2015-01-01
A physical structure such as a cylindrical pipe controls the propagated sound spectrum in a predictable way that can be used to localize the sound source. This paper designs a monaural sound localization system based on multiple pyramidal horns around a single microphone. The acoustic resonance within the horn provides a periodicity in the spectral domain known as the fundamental frequency which is inversely proportional to the radial horn length. Once the system accurately estimates the fundamental frequency, the horn length and corresponding angle can be derived by the relationship. The modified Cepstrum algorithm is employed to evaluate the fundamental frequency. In an anechoic chamber, localization experiments over azimuthal configuration show that up to 61% of the proper signal is recognized correctly with 30% misfire. With a speculated detection threshold, the system estimates direction 52% in positive-to-positive and 34% in negative-to-positive decision rate, on average. PMID:25668214
The risk equivalent of an exposure to-, versus a dose of radiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bond, V.P.
The long-term potential carcinogenic effects of low-level exposure (LLE) are addressed. The principal point discussed is linear, no-threshold dose-response curve. That the linear no-threshold, or proportional relationship is widely used is seen in the way in which the values for cancer risk coefficients are expressed - in terms of new cases, per million persons exposed, per year, per unit exposure or dose. This implies that the underlying relationship is proportional, i.e., ''linear, without threshold''. 12 refs., 9 figs., 1 tab.
Feeney, M. Patrick; Keefe, Douglas H.; Hunter, Lisa L.; Fitzpatrick, Denis F.; Garinis, Angela C.; Putterman, Daniel B.; McMillan, Garnett P.
2016-01-01
Objectives Wideband acoustic immittance (WAI) measures such as pressure reflectance, parameterized by absorbance and group delay, equivalent admittance at the tympanic membrane (TM), and acoustic stapedius reflex threshold (ASRT) describe middle-ear function across a wide frequency range, compared to traditional tests employing a single frequency. The objective of this study was to obtain normative data using these tests for a group of normal hearing adults and investigate test-retest reliability using a longitudinal design. Design A longitudinal prospective design was used to obtain normative test and retest data on clinical and WAI measures. Subjects were 13 males and 20 females (mean age = 25 y). Inclusion criteria included normal audiometry and clinical immittance. Subjects were tested on two separate visits approximately one month apart. Reflectance and equivalent admittance at the TM were measured from 0.25 to 8.0 kHz under three conditions: at ambient pressure in the ear canal and with pressure sweeps from positive to negative pressure (downswept) and negative to positive pressure (upswept). Equivalent admittance at the TM was calculated using admittance measurements at the probe tip which were adjusted using a model of sound transmission in the ear canal and acoustic estimates of ear-canal area and length. Wideband ASRTs were measured at tympanometric peak pressure (TPP) derived from the average TPP of downswept and upswept tympanograms. Descriptive statistics were obtained for all WAI responses, and wideband and clinical ASRTs were compared. Results Mean absorbance at ambient pressure and TPP demonstrated a broad band-pass pattern typical of previous studies. Test-retest differences were lower for absorbance at TPP for the downswept method compared to ambient pressure at frequencies between 1.0 and 1.26 kHz. Mean tympanometric peak-to-tail differences for absorbance were greatest around 1.0 to 2.0 kHz and similar for positive and negative tails. Mean group delay at ambient pressure and at TPP were greatest between 0.32 and 0.6 kHz at 200 to 300 μs, reduced at frequencies between 0.8 and 1.5 kHz, and increased above 1.5 kHz to around 150 μs. Mean equivalent admittance at the TM had a lower level for the ambient method than at TPP for both sweep directions below 1.2 kHz, but the difference between methods was only statistically significant for the comparison between the ambient method and TPP for the upswept tympanogram. Mean equivalent admittance phase was positive at all frequencies. Test-retest reliability of the equivalent admittance level ranged from 1 to 3 dB at frequencies below 1.0 kHz, but increased to 8 to 9 dB at higher frequencies. The mean wideband ASRT for an ipsilateral broadband noise activator was 12 dB lower than the clinical ASRT, but had poorer reliability. Conclusions Normative data for the WAI test battery revealed minor differences for results at ambient pressure compared to tympanometric methods at TPP for reflectance, group delay, and equivalent admittance level at the TM for subjects with middle-ear pressure within ±100 daPa. Test-retest reliability was better for absorbance at TPP for the downswept tympanogram compared to ambient pressure at frequencies around 1.0 kHz. Large peak-to-tail differences in absorbance combined with good reliability at frequencies between about 0.7 and 3.0 kHz suggest that this may be a sensitive frequency range for interpreting absorbance at TPP. The mean wideband ipsilateral ASRT was lower than the clinical ASRT, consistent with previous studies. Results are promising for the use of a wideband test battery to evaluate middle-ear function. PMID:28045835
NASA Astrophysics Data System (ADS)
Gelikonov, V. M.; Romashov, V. N.; Shabanov, D. V.; Ksenofontov, S. Yu.; Terpelov, D. A.; Shilyagin, P. A.; Gelikonov, G. V.; Vitkin, I. A.
2018-05-01
We consider a cross-polarization optical coherence tomography system with a common path for the sounding and reference waves and active maintenance of the circular polarization of a sounding wave. The system is based on the formation of birefringent characteristics of the total optical path, which are equivalent to a quarter-wave plate with a 45° orientation of its optical axes with respect to the linearly polarized reference wave. Conditions under which any light-polarization state can be obtained using a two-element phase controller are obtained. The dependence of the local cross-scattering coefficient of light in a model medium and biological tissue on the sounding-wave polarization state is demonstrated. The necessity of active maintenance of the circular polarization of a sounding wave in this common path system (including a flexible probe) is shown to realize uniform optimal conditions for cross-polarization studies of biological tissue.
Acquisition of Japanese contracted sounds in L1 phonology
NASA Astrophysics Data System (ADS)
Tsurutani, Chiharu
2002-05-01
Japanese possesses a group of palatalized consonants, known to Japanese scholars as the contracted sounds, [CjV]. English learners of Japanese appear to treat them initially as consonant + glide clusters, where there is an equivalent [Cj] cluster in English, or otherwise tend to insert an epenthetic vowel [CVjV]. The acquisition of the Japanese contracted sounds by first language (L1) learners has not been widely studied compared with the consonant clusters in English with which they bear a close phonetic resemblance but have quite a different phonological status. This is a study to investigate the L1 acquisition process of the Japanese contracted sounds (a) in order to observe how the palatalization gesture is acquired in Japanese and (b) to investigate differences in the sound acquisition processes of first and second language (L2) learners: Japanese children compared with English learners. To do this, the productions of Japanese children ranging in age from 2.5 to 3.5 years were transcribed and the pattern of misproduction was observed.
Twardella, Dorothee; Wellhoefer, Andrea; Brix, Jutta; Fromme, Hermann
2008-01-01
While no legal rules or regulations exist in Germany, voluntary measures were introduced to achieve a reduction of sound pressure levels in discotheques to levels below 100 dB(A). To evaluate the current levels in Bavarian discotheques and to find out whether these voluntary measures ensured compliance with the recommended limits, sound pressure levels were measured in 20 Bavarian discotheques between 11 p.m. and 2 a.m. With respect to the equivalent continuous A-weighted sound pressure level for each 30-minute period (L Aeq,30min ), only 4/20 discotheques remained below the limit of 100 dB(A) in all time periods. Ten discotheques had sound pressure levels below 100 dB(A) for the total measurement period (L Aeq,180min ). None of the evaluated factors (weekday, size, estimated age of attendees, the use of voluntary measures such as participation of disc jockeys in a tutorial, or the availability of a sound level meter for the DJs) was significantly associated with the maximal L Aeq, 30min . Thus, the introduction of voluntary measures was not sufficient to ensure compliance with the recommended limits of sound pressure levels.
Discrimination of sound source velocity in human listeners
NASA Astrophysics Data System (ADS)
Carlile, Simon; Best, Virginia
2002-02-01
The ability of six human subjects to discriminate the velocity of moving sound sources was examined using broadband stimuli presented in virtual auditory space. Subjects were presented with two successive stimuli moving in the frontal horizontal plane level with the ears, and were required to judge which moved the fastest. Discrimination thresholds were calculated for reference velocities of 15, 30, and 60 degrees/s under three stimulus conditions. In one condition, stimuli were centered on 0° azimuth and their duration varied randomly to prevent subjects from using displacement as an indicator of velocity. Performance varied between subjects giving median thresholds of 5.5, 9.1, and 14.8 degrees/s for the three reference velocities, respectively. In a second condition, pairs of stimuli were presented for a constant duration and subjects would have been able to use displacement to assist their judgment as faster stimuli traveled further. It was found that thresholds decreased significantly for all velocities (3.8, 7.1, and 9.8 degrees/s), suggesting that the subjects were using the additional displacement cue. The third condition differed from the second in that the stimuli were ``anchored'' on the same starting location rather than centered on the midline, thus doubling the spatial offset between stimulus endpoints. Subjects showed the lowest thresholds in this condition (2.9, 4.0, and 7.0 degrees/s). The results suggested that the auditory system is sensitive to velocity per se, but velocity comparisons are greatly aided if displacement cues are present.
Code of Federal Regulations, 2010 CFR
2010-10-01
... this part. Exchange rate means the change in sound level, in decibels, which would require halving or... audiometric testing, showing the thresholds of hearing sensitivity measured at discrete frequencies, as well... discrete frequencies. Audiometry can also be referred to as audiometric testing. Baseline audiogram means...
47 CFR 15.323 - Specific requirements for devices operating in the 1920-1930 MHz sub-band.
Code of Federal Regulations, 2011 CFR
2011-10-01
... monitoring threshold must not be more than 30 dB above the thermal noise power for a bandwidth equivalent to... windows with the lowest power level below a monitoring threshold of 50 dB above the thermal noise power... of 20 °C. For equipment that is capable only of operating from a battery, the frequency stability...
Lavender, Ashley L; Bartol, Soraya M; Bartol, Ian K
2014-07-15
Sea turtles reside in different acoustic environments with each life history stage and may have different hearing capacity throughout ontogeny. For this study, two independent yet complementary techniques for hearing assessment, i.e. behavioral and electrophysiological audiometry, were employed to (1) measure hearing in post-hatchling and juvenile loggerhead sea turtles Caretta caretta (19-62 cm straight carapace length) to determine whether these migratory turtles exhibit an ontogenetic shift in underwater auditory detection and (2) evaluate whether hearing frequency range and threshold sensitivity are consistent in behavioral and electrophysiological tests. Behavioral trials first required training turtles to respond to known frequencies, a multi-stage, time-intensive process, and then recording their behavior when they were presented with sound stimuli from an underwater speaker using a two-response forced-choice paradigm. Electrophysiological experiments involved submerging restrained, fully conscious turtles just below the air-water interface and recording auditory evoked potentials (AEPs) when sound stimuli were presented using an underwater speaker. No significant differences in behavior-derived auditory thresholds or AEP-derived auditory thresholds were detected between post-hatchling and juvenile sea turtles. While hearing frequency range (50-1000/1100 Hz) and highest sensitivity (100-400 Hz) were consistent in audiograms pooled by size class for both behavior and AEP experiments, both post-hatchlings and juveniles had significantly higher AEP-derived than behavior-derived auditory thresholds, indicating that behavioral assessment is a more sensitive testing approach. The results from this study suggest that post-hatchling and juvenile loggerhead sea turtles are low-frequency specialists, exhibiting little differences in threshold sensitivity and frequency bandwidth despite residence in acoustically distinct environments throughout ontogeny. © 2014. Published by The Company of Biologists Ltd.
Ruhland, Janet L.; Yin, Tom C. T.; Tollin, Daniel J.
2013-01-01
Sound localization accuracy in elevation can be affected by sound spectrum alteration. Correspondingly, any stimulus manipulation that causes a change in the peripheral representation of the spectrum may degrade localization ability in elevation. The present study examined the influence of sound duration and level on localization performance in cats with the head unrestrained. Two cats were trained using operant conditioning to indicate the apparent location of a sound via gaze shift, which was measured with a search-coil technique. Overall, neither sound level nor duration had a notable effect on localization accuracy in azimuth, except at near-threshold levels. In contrast, localization accuracy in elevation improved as sound duration increased, and sound level also had a large effect on localization in elevation. For short-duration noise, the performance peaked at intermediate levels and deteriorated at low and high levels; for long-duration noise, this “negative level effect” at high levels was not observed. Simulations based on an auditory nerve model were used to explain the above observations and to test several hypotheses. Our results indicated that neither the flatness of sound spectrum (before the sound reaches the inner ear) nor the peripheral adaptation influences spectral coding at the periphery for localization in elevation, whereas neural computation that relies on “multiple looks” of the spectral analysis is critical in explaining the effect of sound duration, but not level. The release of negative level effect observed for long-duration sound could not be explained at the periphery and, therefore, is likely a result of processing at higher centers. PMID:23657278
L-type calcium channels refine the neural population code of sound level
Grimsley, Calum Alex; Green, David Brian
2016-01-01
The coding of sound level by ensembles of neurons improves the accuracy with which listeners identify how loud a sound is. In the auditory system, the rate at which neurons fire in response to changes in sound level is shaped by local networks. Voltage-gated conductances alter local output by regulating neuronal firing, but their role in modulating responses to sound level is unclear. We tested the effects of L-type calcium channels (CaL: CaV1.1–1.4) on sound-level coding in the central nucleus of the inferior colliculus (ICC) in the auditory midbrain. We characterized the contribution of CaL to the total calcium current in brain slices and then examined its effects on rate-level functions (RLFs) in vivo using single-unit recordings in awake mice. CaL is a high-threshold current and comprises ∼50% of the total calcium current in ICC neurons. In vivo, CaL activates at sound levels that evoke high firing rates. In RLFs that increase monotonically with sound level, CaL boosts spike rates at high sound levels and increases the maximum firing rate achieved. In different populations of RLFs that change nonmonotonically with sound level, CaL either suppresses or enhances firing at sound levels that evoke maximum firing. CaL multiplies the gain of monotonic RLFs with dynamic range and divides the gain of nonmonotonic RLFs with the width of the RLF. These results suggest that a single broad class of calcium channels activates enhancing and suppressing local circuits to regulate the sensitivity of neuronal populations to sound level. PMID:27605536
Assessment of sound levels in a neonatal intensive care unit in tabriz, iran.
Valizadeh, Sousan; Bagher Hosseini, Mohammad; Alavi, Nasrinsadat; Asadollahi, Malihe; Kashefimehr, Siamak
2013-03-01
High levels of sound have several negative effects, such as noise-induced hearing loss and delayed growth and development, on premature infants in neonatal intensive care units (NICUs). In order to reduce sound levels, they should first be measured. This study was performed to assess sound levels and determine sources of noise in the NICU of Alzahra Teaching Hospital (Tabriz, Iran). In a descriptive study, 24 hours in 4 workdays were randomly selected. Equivalent continuous sound level (Leq), sound level that is exceeded only 10% of the time (L10), maximum sound level (Lmax), and peak instantaneous sound pressure level (Lzpeak) were measured by CEL-440 sound level meter (SLM) at 6 fixed locations in the NICU. Data was collected using a questionnaire. SPSS13 was then used for data analysis. Mean values of Leq, L10, and Lmax were determined as 63.46 dBA, 65.81 dBA, and 71.30 dBA, respectively. They were all higher than standard levels (Leq < 45 dB, L10 ≤50 dB, and Lmax ≤65 dB). The highest Leq was measured at the time of nurse rounds. Leq was directly correlated with the number of staff members present in the ward. Finally, sources of noise were ordered based on their intensity. Considering that sound levels were higher than standard levels in our studied NICU, it is necessary to adopt policies to reduce sound.
Assessment of Sound Levels in a Neonatal Intensive Care Unit in Tabriz, Iran
Valizadeh, Sousan; Bagher Hosseini, Mohammad; Alavi, Nasrinsadat; Asadollahi, Malihe; Kashefimehr, Siamak
2013-01-01
Introduction: High levels of sound have several negative effects, such as noise-induced hearing loss and delayed growth and development, on premature infants in neonatal intensive care units (NICUs). In order to reduce sound levels, they should first be measured. This study was performed to assess sound levels and determine sources of noise in the NICU of Alzahra Teaching Hospital (Tabriz, Iran). Methods: In a descriptive study, 24 hours in 4 workdays were randomly selected. Equivalent continuous sound level (Leq), sound level that is exceeded only 10% of the time (L10), maximum sound level (Lmax), and peak instantaneous sound pressure level (Lzpeak) were measured by CEL-440 sound level meter (SLM) at 6 fixed locations in the NICU. Data was collected using a questionnaire. SPSS13 was then used for data analysis. Results: Mean values of Leq, L10, and Lmax were determined as 63.46 dBA, 65.81 dBA, and 71.30 dBA, respectively. They were all higher than standard levels (Leq < 45 dB, L10 ≤50 dB, and Lmax ≤65 dB). The highest Leq was measured at the time of nurse rounds. Leq was directly correlated with the number of staff members present in the ward. Finally, sources of noise were ordered based on their intensity. Conclusion: Considering that sound levels were higher than standard levels in our studied NICU, it is necessary to adopt policies to reduce sound. PMID:25276706
7 CFR 1484.52 - What are the guidelines for computing the value of non-cash contributions?
Code of Federal Regulations, 2014 CFR
2014-01-01
..., claim up to the equivalent of a step 10, GS-15 for professional personnel and up to the current... value of indirect expenditures. Allocate value on the basis of sound management and accounting...
7 CFR 1484.52 - What are the guidelines for computing the value of non-cash contributions?
Code of Federal Regulations, 2013 CFR
2013-01-01
..., claim up to the equivalent of a step 10, GS-15 for professional personnel and up to the current... value of indirect expenditures. Allocate value on the basis of sound management and accounting...
Identifying a Probabilistic Boolean Threshold Network From Samples.
Melkman, Avraham A; Cheng, Xiaoqing; Ching, Wai-Ki; Akutsu, Tatsuya
2018-04-01
This paper studies the problem of exactly identifying the structure of a probabilistic Boolean network (PBN) from a given set of samples, where PBNs are probabilistic extensions of Boolean networks. Cheng et al. studied the problem while focusing on PBNs consisting of pairs of AND/OR functions. This paper considers PBNs consisting of Boolean threshold functions while focusing on those threshold functions that have unit coefficients. The treatment of Boolean threshold functions, and triplets and -tuplets of such functions, necessitates a deepening of the theoretical analyses. It is shown that wide classes of PBNs with such threshold functions can be exactly identified from samples under reasonable constraints, which include: 1) PBNs in which any number of threshold functions can be assigned provided that all have the same number of input variables and 2) PBNs consisting of pairs of threshold functions with different numbers of input variables. It is also shown that the problem of deciding the equivalence of two Boolean threshold functions is solvable in pseudopolynomial time but remains co-NP complete.
Schulze, W; Schul, J
2001-02-01
The responses of female Tettigonia viridissima to simulated bat echolocation calls were examined during tethered flight. The insects responded with three distinct behaviours, which occurred at graded stimulus intensities. At low intensities (threshold 54 dB SPL), T. viridissima responded by steering away from the sound source (negative phonotaxis). At intensities approximately 10 dB higher, beating of the hindwing was interrupted, although the insect remained in the flight posture. A diving response (cessation of the wingbeat, closure of the forewings and alignment of the legs against the body) occurred with a threshold of 76 dB SPL. Considering these thresholds, we estimate that the diving response occurs at approximately the sound amplitude at which many aerial-hawking bats first receive echoes from the insect. The other behaviours probably occur before the bat detects the insect and should therefore be interpreted as early avoidance behaviours. The repertoire of startle responses in T. viridissima, with directional and non-directional components, is similar to those of crickets and moths, but quite different from those described for another bushcricket (Neoconocephalus ensiger), which shows only a non-directional response. This supports the conclusion that bat-evasive behaviours are not conserved within the Tettigoniidae, but instead are shaped by the ecological constraints of the insects.
Tympanal mechanics and neural responses in the ears of a noctuid moth
NASA Astrophysics Data System (ADS)
Ter Hofstede, Hannah M.; Goerlitz, Holger R.; Montealegre-Z, Fernando; Robert, Daniel; Holderied, Marc W.
2011-12-01
Ears evolved in many groups of moths to detect the echolocation calls of predatory bats. Although the neurophysiology of bat detection has been intensively studied in moths for decades, the relationship between sound-induced movement of the noctuid tympanic membrane and action potentials in the auditory sensory cells (A1 and A2) has received little attention. Using laser Doppler vibrometry, we measured the velocity and displacement of the tympanum in response to pure tone pulses for moths that were intact or prepared for neural recording. When recording from the auditory nerve, the displacement of the tympanum at the neural threshold remained constant across frequencies, whereas velocity varied with frequency. This suggests that the key biophysical parameter for triggering action potentials in the sensory cells of noctuid moths is tympanum displacement, not velocity. The validity of studies on the neurophysiology of moth hearing rests on the assumption that the dissection and recording procedures do not affect the biomechanics of the ear. There were no consistent differences in tympanal velocity or displacement when moths were intact or prepared for neural recordings for sound levels close to neural threshold, indicating that this and other neurophysiological studies provide good estimates of what intact moths hear at threshold.
Hamlet, William R.; Lu, Yong
2016-01-01
Intrinsic plasticity has emerged as an important mechanism regulating neuronal excitability and output under physiological and pathological conditions. Here, we report a novel form of intrinsic plasticity. Using perforated patch clamp recordings, we examined the modulatory effects of group II metabotropic glutamate receptors (mGluR II) on voltage-gated potassium (KV) currents and the firing properties of neurons in the chicken nucleus laminaris (NL), the first central auditory station where interaural time cues are analyzed for sound localization. We found that activation of mGluR II by synthetic agonists resulted in a selective increase of the high threshold KV currents. More importantly, synaptically released glutamate (with reuptake blocked) also enhanced the high threshold KV currents. The enhancement was frequency-coding region dependent, being more pronounced in low frequency neurons compared to middle and high frequency neurons. The intracellular mechanism involved the Gβγ signaling pathway associated with phospholipase C and protein kinase C. The modulation strengthened membrane outward rectification, sharpened action potentials, and improved the ability of NL neurons to follow high frequency inputs. These data suggest that mGluR II provides a feedforward modulatory mechanism that may regulate temporal processing under the condition of heightened synaptic inputs. PMID:26964678
Microphone Handling Noise: Measurements of Perceptual Threshold and Effects on Audio Quality
Kendrick, Paul; Jackson, Iain R.; Fazenda, Bruno M.; Cox, Trevor J.; Li, Francis F.
2015-01-01
A psychoacoustic experiment was carried out to test the effects of microphone handling noise on perceived audio quality. Handling noise is a problem affecting both amateurs using their smartphones and cameras, as well as professionals using separate microphones and digital recorders. The noises used for the tests were measured from a variety of devices, including smartphones, laptops and handheld microphones. The signal features that characterise these noises are analysed and presented. The sounds include various types of transient, impact noises created by tapping or knocking devices, as well as more sustained sounds caused by rubbing. During the perceptual tests, listeners auditioned speech podcasts and were asked to rate the degradation of any unwanted sounds they heard. A representative design test methodology was developed that tried to encourage everyday rather than analytical listening. Signal-to-noise ratio (SNR) of the handling noise events was shown to be the best predictor of quality degradation. Other factors such as noise type or background noise in the listening environment did not significantly affect quality ratings. Podcast, microphone type and reproduction equipment were found to be significant but only to a small extent. A model allowing the prediction of degradation from the SNR is presented. The SNR threshold at which 50% of subjects noticed handling noise was found to be 4.2 ± 0.6 dBA. The results from this work are important for the understanding of our perception of impact sound and resonant noises in recordings, and will inform the future development of an automated predictor of quality for handling noise. PMID:26473498
Sills, Jillian M; Southall, Brandon L; Reichmuth, Colleen
2014-03-01
Spotted seals (Phoca largha) inhabit Arctic regions that are facing both rapid climate change and increasing industrialization. While little is known about their sensory capabilities, available knowledge suggests that spotted seals and other ice seals use sound to obtain information from the surrounding environment. To quantitatively assess their auditory capabilities, the hearing of two young spotted seals was tested using a psychophysical paradigm. Absolute detection thresholds for tonal sounds were measured in air and under water over the frequency range of hearing, and critical ratios were determined using octave-band masking noise in both media. The behavioral audiograms show a range of best sensitivity spanning four octaves in air, from approximately 0.6 to 11 kHz. The range of sensitive hearing extends across seven octaves in water, with lowest thresholds between 0.3 and 56 kHz. Critical ratio measurements were similar in air and water and increased monotonically from 12 dB at 0.1 kHz to 30 dB at 25.6 kHz, indicating that the auditory systems of these seals are quite efficient at extracting signals from background noise. This study demonstrates that spotted seals possess sound reception capabilities different from those previously described for ice seals, and more similar to those reported for harbor seals (Phoca vitulina). The results are consistent with the amphibious lifestyle of these seals and their apparent reliance on sound. The hearing data reported herein are the first available for spotted seals and can inform best management practices for this vulnerable species in a changing Arctic.
Harris, Debra D
2015-01-01
Three flooring materials, terrazzo, rubber, and carpet tile, in patient unit corridors were compared for absorption of sound, comfort, light reflectance, employee perceptions and preferences, and patient satisfaction. Environmental stressors, such as noise and ergonomic factors, effect healthcare workers and patients, contributing to increased fatigue, anxiety and stress, decreased productivity, and patient safety and satisfaction. A longitudinal comparative cohort study comparing three types of flooring assessed sound levels, healthcare worker responses, and patient Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) ratings over 42 weeks. A linear mixed model analysis was conducted to determine significant differences between the means for participant responses and objective sound meter data during all three phases of the study. A significant difference was found for sound levels between flooring type for equivalent continuous sound levels. Carpet tile performed better for sound attenuation by absorption, reducing sound levels 3.14 dBA. Preferences for flooring materials changed over the course of the study. The HCAHPS ratings aligned with the sound meter data showing that patients perceived the noise levels to be lower with carpet tiles, improving patient satisfaction ratings. Perceptions for healthcare staff and patients were aligned with the sound meter data. Carpet tile provides sound absorption that affects sound levels and influences occupant's perceptions of environmental factors that contribute to the quality of the indoor environment. Flooring that provides comfort underfoot, easy cleanability, and sound absorption influence healthcare worker job satisfaction and patient satisfaction with their patient experience. © The Author(s) 2015.
Huang, Shou-Horng; Chen, Ching-Huan; Chen, Chiou-Nan; Wu, Wen-Jer
2013-04-01
The economic threshold (ET) for multiple pest species that share the same injury type on host plants (feeding guild) has been proposed for decision-making in integrated management framework of many defoliating insect pests. However, only a few consider agricultural pests with sucking mouthparts. This study presents the first injury equivalency system for the feeding guild made up of three rice (Oryza sativa L.) planthopper (Hemiptera: Delphacidae) species--Nilaparvata lugens (Stål), Sogatella furcifera (Harváth), and Laodelphax striatellus (Fallén)--by using relative amount of honeydew excretion of each species. The intraspecific injury equivalent coefficient was determined; this coefficient provides an exchange rate for different developmental stages in a species. N. lugens was chosen as the standard species to obtain interspecific injury equivalents for other individuals in the guild, allowing estimates of total guild injury feasible. For extension purposes, the injury equivalency was simplified by pooling all nymphs and adults in the guild to mitigate the potential confusion resulting from uncertainty of instars or wing form. A matrix of ETs established on previous studies and incorporating changes of management cost and rice price was used and served as a control decision guide for the guild samples. The validity of the proposed injury equivalency system was tested using several field data sets, and the results are generally promising and meaningfully elevate the accuracy of estimating combined injury and damage to rice, suggesting that the proposed system is a better integrated pest management decision-making system compared with conventional practices.
Statistical Analysis for Subjective and Objective Evaluations of Dental Drill Sounds
Yamada, Tomomi; Kuwano, Sonoko; Ebisu, Shigeyuki; Hayashi, Mikako
2016-01-01
The sound produced by a dental air turbine handpiece (dental drill) can markedly influence the sound environment in a dental clinic. Indeed, many patients report that the sound of a dental drill elicits an unpleasant feeling. Although several manufacturers have attempted to reduce the sound pressure levels produced by dental drills during idling based on ISO 14457, the sound emitted by such drills under active drilling conditions may negatively influence the dental clinic sound environment. The physical metrics related to the unpleasant impressions associated with dental drill sounds have not been determined. In the present study, psychological measurements of dental drill sounds were conducted with the aim of facilitating improvement of the sound environment at dental clinics. Specifically, we examined the impressions elicited by the sounds of 12 types of dental drills in idling and drilling conditions using a semantic differential. The analysis revealed that the impressions of dental drill sounds varied considerably between idling and drilling conditions and among the examined drills. This finding suggests that measuring the sound of a dental drill in idling conditions alone may be insufficient for evaluating the effects of the sound. We related the results of the psychological evaluations to those of measurements of the physical metrics of equivalent continuous A-weighted sound pressure levels (LAeq) and sharpness. Factor analysis indicated that impressions of the dental drill sounds consisted of two factors: “metallic and unpleasant” and “powerful”. LAeq had a strong relationship with “powerful impression”, calculated sharpness was positively related to “metallic impression”, and “unpleasant impression” was predicted by the combination of both LAeq and calculated sharpness. The present analyses indicate that, in addition to a reduction in sound pressure level, refining the frequency components of dental drill sounds is important for creating a comfortable sound environment in dental clinics. PMID:27462903
Sounds can boost the awareness of visual events through attention without cross-modal integration.
Pápai, Márta Szabina; Soto-Faraco, Salvador
2017-01-31
Cross-modal interactions can lead to enhancement of visual perception, even for visual events below awareness. However, the underlying mechanism is still unclear. Can purely bottom-up cross-modal integration break through the threshold of awareness? We used a binocular rivalry paradigm to measure perceptual switches after brief flashes or sounds which, sometimes, co-occurred. When flashes at the suppressed eye coincided with sounds, perceptual switches occurred the earliest. Yet, contrary to the hypothesis of cross-modal integration, this facilitation never surpassed the assumption of probability summation of independent sensory signals. A follow-up experiment replicated the same pattern of results using silent gaps embedded in continuous noise, instead of sounds. This manipulation should weaken putative sound-flash integration, although keep them salient as bottom-up attention cues. Additional results showed that spatial congruency between flashes and sounds did not determine the effectiveness of cross-modal facilitation, which was again not better than probability summation. Thus, the present findings fail to fully support the hypothesis of bottom-up cross-modal integration, above and beyond the independent contribution of two transient signals, as an account for cross-modal enhancement of visual events below level of awareness.
Sanchez, Tanit Ganz; Moraes, Fernanda; Casseb, Juliana; Cota, Jaci; Freire, Katya; Roberts, Larry E.
2016-01-01
Recent neuroscience research suggests that tinnitus may reflect synaptic loss in the cochlea that does not express in the audiogram but leads to neural changes in auditory pathways that reduce sound level tolerance (SLT). Adolescents (N = 170) completed a questionnaire addressing their prior experience with tinnitus, potentially risky listening habits, and sensitivity to ordinary sounds, followed by psychoacoustic measurements in a sound booth. Among all adolescents 54.7% reported by questionnaire that they had previously experienced tinnitus, while 28.8% heard tinnitus in the booth. Psychoacoustic properties of tinnitus measured in the sound booth corresponded with those of chronic adult tinnitus sufferers. Neither hearing thresholds (≤15 dB HL to 16 kHz) nor otoacoustic emissions discriminated between adolescents reporting or not reporting tinnitus in the sound booth, but loudness discomfort levels (a psychoacoustic measure of SLT) did so, averaging 11.3 dB lower in adolescents experiencing tinnitus in the acoustic chamber. Although risky listening habits were near universal, the teenagers experiencing tinnitus and reduced SLT tended to be more protective of their hearing. Tinnitus and reduced SLT could be early indications of a vulnerability to hidden synaptic injury that is prevalent among adolescents and expressed following exposure to high level environmental sounds. PMID:27265722
Anaerobic Threshold and Salivary α-amylase during Incremental Exercise.
Akizuki, Kazunori; Yazaki, Syouichirou; Echizenya, Yuki; Ohashi, Yukari
2014-07-01
[Purpose] The purpose of this study was to clarify the validity of salivary α-amylase as a method of quickly estimating anaerobic threshold and to establish the relationship between salivary α-amylase and double-product breakpoint in order to create a way to adjust exercise intensity to a safe and effective range. [Subjects and Methods] Eleven healthy young adults performed an incremental exercise test using a cycle ergometer. During the incremental exercise test, oxygen consumption, carbon dioxide production, and ventilatory equivalent were measured using a breath-by-breath gas analyzer. Systolic blood pressure and heart rate were measured to calculate the double product, from which double-product breakpoint was determined. Salivary α-amylase was measured to calculate the salivary threshold. [Results] One-way ANOVA revealed no significant differences among workloads at the anaerobic threshold, double-product breakpoint, and salivary threshold. Significant correlations were found between anaerobic threshold and salivary threshold and between anaerobic threshold and double-product breakpoint. [Conclusion] As a method for estimating anaerobic threshold, salivary threshold was as good as or better than determination of double-product breakpoint because the correlation between anaerobic threshold and salivary threshold was higher than the correlation between anaerobic threshold and double-product breakpoint. Therefore, salivary threshold is a useful index of anaerobic threshold during an incremental workload.
The difference between “equivalent” and “not different”
Anderson-Cook, Christine M.; Borror, Connie M.
2015-10-27
Often, experimenters wish to establish that populations of units can be considered equivalent to each other, in order to leverage improved knowledge about one population for characterizing the new population, or to establish the comparability of items. Equivalence tests have existed for many years, but their use in industry seems to have been largely restricted to biomedical applications, such as for assessing the equivalence of two drugs or protocols. We present the fundamentals of equivalence tests, compare them to traditional two-sample and ANOVA tests that are better suited to establishing differences in populations, and propose the use of a graphicalmore » summary to compare p-values across different thresholds of practically important differences.« less
Döge, Julia; Baumann, Uwe; Weissgerber, Tobias; Rader, Tobias
2017-12-01
To assess auditory localization accuracy and speech reception threshold (SRT) in complex noise conditions in adult patients with acquired single-sided deafness, after intervention with a cochlear implant (CI) in the deaf ear. Nonrandomized, open, prospective patient series. Tertiary referral university hospital. Eleven patients with late-onset single-sided deafness (SSD) and normal hearing in the unaffected ear, who received a CI. All patients were experienced CI users. Unilateral cochlear implantation. Speech perception was tested in a complex multitalker equivalent noise field consisting of multiple sound sources. Speech reception thresholds in noise were determined in aided (with CI) and unaided conditions. Localization accuracy was assessed in complete darkness. Acoustic stimuli were radiated by multiple loudspeakers distributed in the frontal horizontal plane between -60 and +60 degrees. In the aided condition, results show slightly improved speech reception scores compared with the unaided condition in most of the patients. For 8 of the 11 subjects, SRT was improved between 0.37 and 1.70 dB. Three of the 11 subjects showed deteriorations between 1.22 and 3.24 dB SRT. Median localization error decreased significantly by 12.9 degrees compared with the unaided condition. CI in single-sided deafness is an effective treatment to improve the auditory localization accuracy. Speech reception in complex noise conditions is improved to a lesser extent in 73% of the participating CI SSD patients. However, the absence of true binaural interaction effects (summation, squelch) impedes further improvements. The development of speech processing strategies that respect binaural interaction seems to be mandatory to advance speech perception in demanding listening situations in SSD patients.
Identifying equivalent sound sources from aeroacoustic simulations using a numerical phased array
NASA Astrophysics Data System (ADS)
Pignier, Nicolas J.; O'Reilly, Ciarán J.; Boij, Susann
2017-04-01
An application of phased array methods to numerical data is presented, aimed at identifying equivalent flow sound sources from aeroacoustic simulations. Based on phased array data extracted from compressible flow simulations, sound source strengths are computed on a set of points in the source region using phased array techniques assuming monopole propagation. Two phased array techniques are used to compute the source strengths: an approach using a Moore-Penrose pseudo-inverse and a beamforming approach using dual linear programming (dual-LP) deconvolution. The first approach gives a model of correlated sources for the acoustic field generated from the flow expressed in a matrix of cross- and auto-power spectral values, whereas the second approach results in a model of uncorrelated sources expressed in a vector of auto-power spectral values. The accuracy of the equivalent source model is estimated by computing the acoustic spectrum at a far-field observer. The approach is tested first on an analytical case with known point sources. It is then applied to the example of the flow around a submerged air inlet. The far-field spectra obtained from the source models for two different flow conditions are in good agreement with the spectra obtained with a Ffowcs Williams-Hawkings integral, showing the accuracy of the source model from the observer's standpoint. Various configurations for the phased array and for the sources are used. The dual-LP beamforming approach shows better robustness to changes in the number of probes and sources than the pseudo-inverse approach. The good results obtained with this simulation case demonstrate the potential of the phased array approach as a modelling tool for aeroacoustic simulations.
Amaral, Joice A T; Nogueira, Marcela L; Roque, Adriano L; Guida, Heraldo L; De Abreu, Luiz Carlos; Raimundo, Rodrigo Daminello; Vanderlei, Luiz Carlos M; Ribeiro, Vivian L; Ferreira, Celso; Valenti, Vitor E
2014-03-01
The effects of chronic music auditory stimulation on the cardiovascular system have been investigated in the literature. However, data regarding the acute effects of different styles of music on cardiac autonomic regulation are lacking. The literature has indicated that auditory stimulation with white noise above 50 dB induces cardiac responses. We aimed to evaluate the acute effects of classical baroque and heavy metal music of different intensities on cardiac autonomic regulation. The study was performed in 16 healthy men aged 18-25 years. All procedures were performed in the same soundproof room. We analyzed heart rate variability (HRV) in time (standard deviation of normal-to-normal R-R intervals [SDNN], root-mean square of differences [RMSSD] and percentage of adjacent NN intervals with a difference of duration greater than 50 ms [pNN50]) and frequency (low frequency [LF], high frequency [HF] and LF/HF ratio) domains. HRV was recorded at rest for 10 minutes. Subsequently, the volunteers were exposed to one of the two musical styles (classical baroque or heavy metal music) for five minutes through an earphone, followed by a five-minute period of rest, and then they were exposed to the other style for another five minutes. The subjects were exposed to three equivalent sound levels (60-70dB, 70-80dB and 80-90dB). The sequence of songs was randomized for each individual. Auditory stimulation with heavy metal music did not influence HRV indices in the time and frequency domains in the three equivalent sound level ranges. The same was observed with classical baroque musical auditory stimulation with the three equivalent sound level ranges. Musical auditory stimulation of different intensities did not influence cardiac autonomic regulation in men.
Optical Sound Generation and Amplification
1983-01-15
acoustic cavitation threshold of water with concentration of the polymer additives polyethylene oxide and guar gum . It was found that small amounts of...Technical Library 2800 Powder Mill Road Adelphi, Maryland 20783 1 copy 3 copies 1 copy 1 copy 1 copy 1 copy 1 copy Naval Air Development Center
Wind turbines and health: a critical review of the scientific literature.
McCunney, Robert J; Mundt, Kenneth A; Colby, W David; Dobie, Robert; Kaliski, Kenneth; Blais, Mark
2014-11-01
This review examines the literature related to health effects of wind turbines. We reviewed literature related to sound measurements near turbines, epidemiological and experimental studies, and factors associated with annoyance. (1) Infrasound sound near wind turbines does not exceed audibility thresholds. (2) Epidemiological studies have shown associations between living near wind turbines and annoyance. (3) Infrasound and low-frequency sound do not present unique health risks. (4) Annoyance seems more strongly related to individual characteristics than noise from turbines. Further areas of inquiry include enhanced noise characterization, analysis of predicted noise values contrasted with measured levels postinstallation, longitudinal assessments of health pre- and postinstallation, experimental studies in which subjects are "blinded" to the presence or absence of infrasound, and enhanced measurement techniques to evaluate annoyance.
Characterization of holding brake friction pad surface after pin-on-plate wear test
NASA Astrophysics Data System (ADS)
Drago, N.; Gonzalez Madruga, D.; De Chiffre, L.
2018-03-01
This article concerns the metrological characterization of the surface on a holding brake friction material pin after a pin-on-plate (POP) wear test. The POP test induces the formation of surface plateaus that affect brake performances such as wear, friction, noise and heat. Three different materials’ surfaces have been characterized after wear from data obtained with a focus variation 3D microscope. A new surface characterization approach with plateau identification is proposed, using the number of plateau on the surface, equivalent diameter, length and breadth as measurands. The identification method is based on determining and imposing ISO 27158-2 lower plateau limit (LPL) in material probability curves; and on applying a combined criterion of height segmentation threshold and equivalent diameter threshold. The method determines the criterion thresholds for each material since LPL appears typical by material. The proposed method has allowed quantifying the surface topography at two different levels of wear. An expanded measurement uncertainty of 3.5 µm for plateau dimensions in the range 50–2000 µm and one of 0.15 µm for plateau heights up to 10 µm have been documented.
NASA Astrophysics Data System (ADS)
Samardzic, Nikolina
The effectiveness of in-vehicle speech communication can be a good indicator of the perception of the overall vehicle quality and customer satisfaction. Currently available speech intelligibility metrics do not account in their procedures for essential parameters needed for a complete and accurate evaluation of in-vehicle speech intelligibility. These include the directivity and the distance of the talker with respect to the listener, binaural listening, hearing profile of the listener, vocal effort, and multisensory hearing. In the first part of this research the effectiveness of in-vehicle application of these metrics is investigated in a series of studies to reveal their shortcomings, including a wide range of scores resulting from each of the metrics for a given measurement configuration and vehicle operating condition. In addition, the nature of a possible correlation between the scores obtained from each metric is unknown. The metrics and the subjective perception of speech intelligibility using, for example, the same speech material have not been compared in literature. As a result, in the second part of this research, an alternative method for speech intelligibility evaluation is proposed for use in the automotive industry by utilizing a virtual reality driving environment for ultimately setting targets, including the associated statistical variability, for future in-vehicle speech intelligibility evaluation. The Speech Intelligibility Index (SII) was evaluated at the sentence Speech Receptions Threshold (sSRT) for various listening situations and hearing profiles using acoustic perception jury testing and a variety of talker and listener configurations and background noise. In addition, the effect of individual sources and transfer paths of sound in an operating vehicle to the vehicle interior sound, specifically their effect on speech intelligibility was quantified, in the framework of the newly developed speech intelligibility evaluation method. Lastly, as an example of the significance of speech intelligibility evaluation in the context of an applicable listening environment, as indicated in this research, it was found that the jury test participants required on average an approximate 3 dB increase in sound pressure level of speech material while driving and listening compared to when just listening, for an equivalent speech intelligibility performance and the same listening task.
Wireless and acoustic hearing with bone-anchored hearing devices.
Bosman, Arjan J; Mylanus, Emmanuel A M; Hol, Myrthe K S; Snik, Ad F M
2015-07-01
The efficacy of wireless connectivity in bone-anchored hearing was studied by comparing the wireless and acoustic performance of the Ponto Plus sound processor from Oticon Medical relative to the acoustic performance of its predecessor, the Ponto Pro. Nineteen subjects with more than two years' experience with a bone-anchored hearing device were included. Thirteen subjects were fitted unilaterally and six bilaterally. Subjects served as their own control. First, subjects were tested with the Ponto Pro processor. After a four-week acclimatization period performance the Ponto Plus processor was measured. In the laboratory wireless and acoustic input levels were made equal. In daily life equal settings of wireless and acoustic input were used when watching TV, however when using the telephone the acoustic input was reduced by 9 dB relative to the wireless input. Speech scores for microphone with Ponto Pro and for both input modes of the Ponto Plus processor were essentially equal when equal input levels of wireless and microphone inputs were used. Only the TV-condition showed a statistically significant (p <5%) lower speech reception threshold for wireless relative to microphone input. In real life, evaluation of speech quality, speech intelligibility in quiet and noise, and annoyance by ambient noise, when using landline phone, mobile telephone, and watching TV showed a clear preference (p <1%) for the Ponto Plus system with streamer over the microphone input. Due to the small number of respondents with landline phone (N = 7) the result for noise annoyance was only significant at the 5% level. Equal input levels for acoustic and wireless inputs results in equal speech scores, showing a (near) equivalence for acoustic and wireless sound transmission with Ponto Pro and Ponto Plus. The default 9-dB difference between microphone and wireless input when using the telephone results in a substantial wireless benefit when using the telephone. The preference of wirelessly transmitted audio when watching TV can be attributed to the relatively poor sound quality of backward facing loudspeakers in flat screen TVs. The ratio of wireless and acoustic input can be easily set to the user's preference with the streamer's volume control.
A derivation of the stable cavitation threshold accounting for bubble-bubble interactions.
Guédra, Matthieu; Cornu, Corentin; Inserra, Claude
2017-09-01
The subharmonic emission of sound coming from the nonlinear response of a bubble population is the most used indicator for stable cavitation. When driven at twice their resonance frequency, bubbles can exhibit subharmonic spherical oscillations if the acoustic pressure amplitude exceeds a threshold value. Although various theoretical derivations exist for the subharmonic emission by free or coated bubbles, they all rest on the single bubble model. In this paper, we propose an analytical expression of the subharmonic threshold for interacting bubbles in a homogeneous, monodisperse cloud. This theory predicts a shift of the subharmonic resonance frequency and a decrease of the corresponding pressure threshold due to the interactions. For a given sonication frequency, these results show that an optimal value of the interaction strength (i.e. the number density of bubbles) can be found for which the subharmonic threshold is minimum, which is consistent with recently published experiments conducted on ultrasound contrast agents. Copyright © 2017 Elsevier B.V. All rights reserved.
Nociception at the diabetic foot, an uncharted territory
Chantelau, Ernst A
2015-01-01
The diabetic foot is characterised by painless foot ulceration and/or arthropathy; it is a typical complication of painless diabetic neuropathy. Neuropathy depletes the foot skin of intraepidermal nerve fibre endings of the afferent A-delta and C-fibres, which are mostly nociceptors and excitable by noxious stimuli only. However, some of them are cold or warm receptors whose functions in diabetic neuropathy have frequently been reported. Hence, it is well established by quantitative sensory testing that thermal detection thresholds at the foot skin increase during the course of painless diabetic neuropathy. Pain perception (nociception), by contrast, has rarely been studied. Recent pilot studies of pinprick pain at plantar digital skinfolds showed that the perception threshold was always above the upper limit of measurement of 512 mN (equivalent to 51.2 g) at the diabetic foot. However, deep pressure pain perception threshold at musculus abductor hallucis was beyond 1400 kPa (equivalent to 14 kg; limit of measurement) only in every fifth case. These discrepancies of pain perception between forefoot and hindfoot, and between skin and muscle, demand further study. Measuring nociception at the feet in diabetes opens promising clinical perspectives. A critical nociception threshold may be quantified (probably corresponding to a critical number of intraepidermal nerve fibre endings), beyond which the individual risk of a diabetic foot rises appreciably. Staging of diabetic neuropathy according to nociception thresholds at the feet is highly desirable as guidance to an individualised injury prevention strategy. PMID:25897350
L-type calcium channels refine the neural population code of sound level.
Grimsley, Calum Alex; Green, David Brian; Sivaramakrishnan, Shobhana
2016-12-01
The coding of sound level by ensembles of neurons improves the accuracy with which listeners identify how loud a sound is. In the auditory system, the rate at which neurons fire in response to changes in sound level is shaped by local networks. Voltage-gated conductances alter local output by regulating neuronal firing, but their role in modulating responses to sound level is unclear. We tested the effects of L-type calcium channels (Ca L : Ca V 1.1-1.4) on sound-level coding in the central nucleus of the inferior colliculus (ICC) in the auditory midbrain. We characterized the contribution of Ca L to the total calcium current in brain slices and then examined its effects on rate-level functions (RLFs) in vivo using single-unit recordings in awake mice. Ca L is a high-threshold current and comprises ∼50% of the total calcium current in ICC neurons. In vivo, Ca L activates at sound levels that evoke high firing rates. In RLFs that increase monotonically with sound level, Ca L boosts spike rates at high sound levels and increases the maximum firing rate achieved. In different populations of RLFs that change nonmonotonically with sound level, Ca L either suppresses or enhances firing at sound levels that evoke maximum firing. Ca L multiplies the gain of monotonic RLFs with dynamic range and divides the gain of nonmonotonic RLFs with the width of the RLF. These results suggest that a single broad class of calcium channels activates enhancing and suppressing local circuits to regulate the sensitivity of neuronal populations to sound level. Copyright © 2016 the American Physiological Society.
Comparison of airborne lidar measurements with 420 kHz echo-sounder measurements of zooplankton.
Churnside, James H; Thorne, Richard E
2005-09-10
Airborne lidar has the potential to survey large areas quickly and at a low cost per kilometer along a survey line. For this reason, we investigated the performance of an airborne lidar for surveys of zooplankton. In particular, we compared the lidar returns with echo-sounder measurements of zooplankton in Prince William Sound, Alaska. Data from eight regions of the Sound were compared, and the correlation between the two methods was 0.78. To obtain this level of agreement, a threshold was applied to the lidar return to remove the effects of scattering from phytoplankton.
Great Ears: Low-Frequency Sensitivity Correlates in Land and Marine Leviathans.
Ketten, D R; Arruda, J; Cramer, S; Yamato, M
2016-01-01
Like elephants, baleen whales produce low-frequency (LF) and even infrasonic (IF) signals, suggesting they may be particularly susceptible to underwater anthropogenic sound impacts. Analyses of computerized tomography scans and histologies of the ears in five baleen whale and two elephant species revealed that LF thresholds correlate with basilar membrane thickness/width and cochlear radii ratios. These factors are consistent with high-mass, low-stiffness membranes and broad spiral curvatures, suggesting that Mysticeti and Proboscidea evolved common inner ear adaptations over similar time scales for processing IF/LF sounds despite operating in different media.
[Auditory processing and high frequency audiometry in students of São Paulo].
Ramos, Cristina Silveira; Pereira, Liliane Desgualdo
2005-01-01
Auditory processing and auditory sensibility to high Frequency sounds. To characterize the localization processes, temporal ordering, hearing patterns and detection of high frequency sounds, looking for possible relations between these factors. 32 hearing fourth grade students, born in city of São Paulo, were submitted to: a simplified evaluation of the auditory processing; duration pattern test; high frequency audiometry. Three (9,4%) individuals presented auditory processing disorder (APD) and in one of them there was the coexistence of lower hearing thresholds in high frequency audiometry. APD associated to an auditory sensibility loss in high frequencies should be further investigated.
Tanaka, Tagayasu; Inaba, Ryoichi; Aoyama, Atsuhito
2016-01-01
Objectives: This study investigated the actual situation of noise and low-frequency sounds in firework events and their impact on pyrotechnicians. Methods: Data on firework noise and low-frequency sounds were obtained at a point located approximately 100 m away from the launch site of a firework display held in "A" City in 2013. We obtained the data by continuously measuring and analyzing the equivalent continuous sound level (Leq) and the one-third octave band of the noise and low-frequency sounds emanating from the major firework detonations, and predicted sound levels at the original launch site. Results: Sound levels of 100-115 dB and low-frequency sounds of 100-125 dB were observed at night. The maximum and mean Leq values were 97 and 95 dB, respectively. The launching noise level predicted from the sounds (85 dB) at the noise measurement point was 133 dB. Occupational exposure to noise for pyrotechnicians at the remote operation point (located 20-30 m away from the launch site) was estimated to be below 100 dB. Conclusions: Pyrotechnicians are exposed to very loud noise (>100 dB) at the launch point. We believe that it is necessary to implement measures such as fixing earplugs or earmuffs, posting a warning at the workplace, and executing a remote launching operation to prevent hearing loss caused by occupational exposure of pyrotechnicians to noise. It is predicted that both sound levels and low-frequency sounds would be reduced by approximately 35 dB at the remote operation site. PMID:27725489
Tanaka, Tagayasu; Inaba, Ryoichi; Aoyama, Atsuhito
2016-11-29
This study investigated the actual situation of noise and low-frequency sounds in firework events and their impact on pyrotechnicians. Data on firework noise and low-frequency sounds were obtained at a point located approximately 100 m away from the launch site of a firework display held in "A" City in 2013. We obtained the data by continuously measuring and analyzing the equivalent continuous sound level (Leq) and the one-third octave band of the noise and low-frequency sounds emanating from the major firework detonations, and predicted sound levels at the original launch site. Sound levels of 100-115 dB and low-frequency sounds of 100-125 dB were observed at night. The maximum and mean Leq values were 97 and 95 dB, respectively. The launching noise level predicted from the sounds (85 dB) at the noise measurement point was 133 dB. Occupational exposure to noise for pyrotechnicians at the remote operation point (located 20-30 m away from the launch site) was estimated to be below 100 dB. Pyrotechnicians are exposed to very loud noise (>100 dB) at the launch point. We believe that it is necessary to implement measures such as fixing earplugs or earmuffs, posting a warning at the workplace, and executing a remote launching operation to prevent hearing loss caused by occupational exposure of pyrotechnicians to noise. It is predicted that both sound levels and low-frequency sounds would be reduced by approximately 35 dB at the remote operation site.
NASA Astrophysics Data System (ADS)
Bi, Chuan-Xing; Hu, Ding-Yu; Zhang, Yong-Bin; Jing, Wen-Qian
2015-06-01
In previous studies, an equivalent source method (ESM)-based technique for recovering the free sound field in a noisy environment has been successfully applied to exterior problems. In order to evaluate its performance when applied to a more general noisy environment, that technique is used to identify active sources inside cavities where the sound field is composed of the field radiated by active sources and that reflected by walls. A patch approach with two semi-closed surfaces covering the target active sources is presented to perform the measurements, and the field that would be radiated by these target active sources into free space is extracted from the mixed field by using the proposed technique, which will be further used as the input of nearfield acoustic holography for source identification. Simulation and experimental results validate the effectiveness of the proposed technique for source identification in cavities, and show the feasibility of performing the measurements with a double layer planar array.
Annoyance, detection and recognition of wind turbine noise.
Van Renterghem, Timothy; Bockstael, Annelies; De Weirt, Valentine; Botteldooren, Dick
2013-07-01
Annoyance, recognition and detection of noise from a single wind turbine were studied by means of a two-stage listening experiment with 50 participants with normal hearing abilities. In-situ recordings made at close distance from a 1.8-MW wind turbine operating at 22 rpm were mixed with road traffic noise, and processed to simulate indoor sound pressure levels at LAeq 40 dBA. In a first part, where people were unaware of the true purpose of the experiment, samples were played during a quiet leisure activity. Under these conditions, pure wind turbine noise gave very similar annoyance ratings as unmixed highway noise at the same equivalent level, while annoyance by local road traffic noise was significantly higher. In a second experiment, listeners were asked to identify the sample containing wind turbine noise in a paired comparison test. The detection limit of wind turbine noise in presence of highway noise was estimated to be as low as a signal-to-noise ratio of -23 dBA. When mixed with local road traffic, such a detection limit could not be determined. These findings support that noticing the sound could be an important aspect of wind turbine noise annoyance at the low equivalent levels typically observed indoors in practice. Participants that easily recognized wind-turbine(-like) sounds could detect wind turbine noise better when submersed in road traffic noise. Recognition of wind turbine sounds is also linked to higher annoyance. Awareness of the source is therefore a relevant aspect of wind turbine noise perception which is consistent with previous research. Copyright © 2013 Elsevier B.V. All rights reserved.
[HYGIENIC ASSESSMENT OF NOISE FACTOR OF THE LARGE CITY].
Chubirko, M L; Stepkin, Yu I; Seredenko, O V
2015-01-01
The article is devoted to the problem of the negative impact of traffic noise on the health and living conditions of the population in conditions of the large city. Every day on the streets there are appeared more and more different modes of transport, and to date almost all transportation network has reached his traffic performance. The increase in traffic noise certainly has an impact on the human body. The most common and intense noise is caused by the traffic of urban automobile and electric transport. This is explained by the existence of the heavy traffic (2-3 thousand crews/h) on almost all main roads in historically emerged parts of the city. In addition, sources of external noise in the city can be a railway running in residential zone, access roads, industrial enterprises, located in close proximity to residential areas and on the borders of residential zones, planes of military and civil aviation. For the evaluation of the different noises sound levels were measured with the use of sound level meters. The most common parameter for the assessment ofthe noise generatedfrom motor vehicles on residential areas and usedfor the noise characteristics of the traffic flows, is the equivalent sound level/A EQ dB. This parameter is used in the majority of normative-technical documentation as hygienic noise standard. With the aim of the assessment of noise exposure there were selected 122 control points at intersections of roads of different traffic performance where there were made instrumental measurements the equivalent sound level, followed by its comparison with permissible levels.
Eye-movements intervening between two successive sounds disrupt comparisons of auditory location
Pavani, Francesco; Husain, Masud; Driver, Jon
2008-01-01
Summary Many studies have investigated how saccades may affect the internal representation of visual locations across eye-movements. Here we studied instead whether eye-movements can affect auditory spatial cognition. In two experiments, participants judged the relative azimuth (same/different) of two successive sounds presented from a horizontal array of loudspeakers, separated by a 2.5 secs delay. Eye-position was either held constant throughout the trial (being directed in a fixed manner to the far left or right of the loudspeaker array), or had to be shifted to the opposite side of the array during the retention delay between the two sounds, after the first sound but before the second. Loudspeakers were either visible (Experiment1) or occluded from sight (Experiment 2). In both cases, shifting eye-position during the silent delay-period affected auditory performance in the successive auditory comparison task, even though the auditory inputs to be judged were equivalent. Sensitivity (d′) for the auditory discrimination was disrupted, specifically when the second sound shifted in the opposite direction to the intervening eye-movement with respect to the first sound. These results indicate that eye-movements affect internal representation of auditory location. PMID:18566808
Eye-movements intervening between two successive sounds disrupt comparisons of auditory location.
Pavani, Francesco; Husain, Masud; Driver, Jon
2008-08-01
Many studies have investigated how saccades may affect the internal representation of visual locations across eye-movements. Here, we studied, instead, whether eye-movements can affect auditory spatial cognition. In two experiments, participants judged the relative azimuth (same/different) of two successive sounds presented from a horizontal array of loudspeakers, separated by a 2.5-s delay. Eye-position was either held constant throughout the trial (being directed in a fixed manner to the far left or right of the loudspeaker array) or had to be shifted to the opposite side of the array during the retention delay between the two sounds, after the first sound but before the second. Loudspeakers were either visible (Experiment 1) or occluded from sight (Experiment 2). In both cases, shifting eye-position during the silent delay-period affected auditory performance in thn the successive auditory comparison task, even though the auditory inputs to be judged were equivalent. Sensitivity (d') for the auditory discrimination was disrupted, specifically when the second sound shifted in the opposite direction to the intervening eye-movement with respect to the first sound. These results indicate that eye-movements affect internal representation of auditory location.
Hooten, W Michael; Qu, Wenchun; Townsend, Cynthia O; Judd, Jeffrey W
2012-04-01
Strength training and aerobic exercise have beneficial effects on pain in adults with fibromyalgia. However, the equivalence of strengthening and aerobic exercise has not been reported. The primary aim of this randomized equivalence trial involving patients with fibromyalgia admitted to an interdisciplinary pain treatment program was to test the hypothesis that strengthening (n=36) and aerobic (n=36) exercise have equivalent effects (95% confidence interval within an equivalence margin ± 8) on pain, as measured by the pain severity subscale of the Multidimensional Pain Inventory. Secondary aims included determining the effects of strengthening and aerobic exercise on peak Vo(2) uptake, leg strength, and pressure pain thresholds. In an intent-to-treat analysis, the mean (± standard deviation) pain severity scores for the strength and aerobic groups at study completion were 34.4 ± 11.5 and 37.6 ± 11.9, respectively. The group difference was -3.2 (95% confidence interval, -8.7 to 2.3), which was within the equivalence margin of Δ8. Significant improvements in pain severity (P<.001), peak Vo(2) (P<.001), strength (P<.001), and pain thresholds (P<.001) were observed from baseline to week 3 in the intent-to-treat analysis; however, patients in the aerobic group (mean change 2.0 ± 2.6 mL/kg/min) experienced greater gains (P<.013) in peak Vo(2) compared to the strength group (mean change 0.4 ± 2.6 mL/kg/min). Knowledge of the equivalence and physiological effects of exercise have important clinical implications that could allow practitioners to target exercise recommendations on the basis of comorbid medical conditions or patient preference for a particular type of exercise. This study found that strength and aerobic exercise had equivalent effects on reducing pain severity among patients with fibromyalgia. Copyright © 2012 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Nelson, Paul C; Smith, Zachary M; Young, Eric D
2009-02-25
An organism's ability to detect and discriminate sensory inputs depends on the recent stimulus history. For example, perceptual detection thresholds for a brief tone can be elevated by as much as 50 dB when following a masking stimulus. Previous work suggests that such forward masking is not a direct result of peripheral neural adaptation; the central pathway apparently modifies the representation in a way that further attenuates the input's response to short probe signals. Here, we show that much of this transformation is complete by the level of the inferior colliculus (IC). Single-neuron extracellular responses were recorded in the central nucleus of the awake marmoset IC. The threshold for a 20 ms probe tone presented at best frequency was determined for various masker-probe delays, over a range of masker sound pressure levels (SPLs) and frequencies. The most striking aspect of the data was the increased potency of forward maskers as their SPL was increased, despite the fact that the excitatory response to the masker was often saturating or nonmonotonic over the same range of levels. This led to probe thresholds at high masker levels that were almost always higher than those observed in the auditory nerve. Probe threshold shifts were not usually caused by a persistent excitatory response to the masker; instead we propose a wide-dynamic-range inhibitory mechanism locked to sound offset as an explanation for several key aspects of the data. These findings further delineate the role of subcortical auditory processing in the generation of a context-dependent representation of ongoing acoustic scenes.
van Hooff, Miranda L; Mannion, Anne F; Staub, Lukas P; Ostelo, Raymond W J G; Fairbank, Jeremy C T
2016-10-01
The achievement of a given change score on a valid outcome instrument is commonly used to indicate whether a clinically relevant change has occurred after spine surgery. However, the achievement of such a change score can be dependent on baseline values and does not necessarily indicate whether the patient is satisfied with the current state. The achievement of an absolute score equivalent to a patient acceptable symptom state (PASS) may be a more stringent measure to indicate treatment success. This study aimed to estimate the score on the Oswestry Disability Index (ODI, version 2.1a; 0-100) corresponding to a PASS in patients who had undergone surgery for degenerative disorders of the lumbar spine. This is a cross-sectional study of diagnostic accuracy using follow-up data from an international spine surgery registry. The sample includes 1,288 patients with degenerative lumbar spine disorders who had undergone elective spine surgery, registered in the EUROSPINE Spine Tango Spine Surgery Registry. The main outcome measure was the ODI (version 2.1a). Surgical data and data from the ODI and Core Outcome Measures Index (COMI) were included to determine the ODI threshold equivalent to PASS at 1 year (±1.5 months; n=780) and 2 years (±2 months; n=508) postoperatively. The symptom-specific well-being item of the COMI was used as the external criterion in the receiver operating characteristic (ROC) analysis to determine the ODI threshold equivalent to PASS. Separate sensitivity analyses were performed based on the different definitions of an "acceptable state" and for subgroups of patients. JF is a copyright holder of the ODI. The ODI threshold for PASS was 22, irrespective of the time of follow-up (area under the curve [AUC]: 0.89 [sensitivity {Se}: 78.3%, specificity {Sp}: 82.1%] and AUC: 0.91 [Se: 80.7%, Sp: 85.6] for the 1- and 2-year follow-ups, respectively). Sensitivity analyses showed that the absolute ODI-22 threshold for the two follow-up time-points were robust. A stricter definition of PASS resulted in lower ODI thresholds, varying from 16 (AUC=0.89; Se: 80.2%, Sp: 82.0%) to 18 (AUC=0.90; Se: 82.4%, Sp: 80.4%) depending on the time of follow-up. An ODI score ≤22 indicates the achievement of an acceptable symptom state and can hence be used as a criterion of treatment success alongside the commonly used change score measures. At the individual level, the threshold could be used to indicate whether or not a patient with a lumbar spine disorder is a "responder" after elective surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
Improving Accuracy in Detecting Acoustic Onsets
ERIC Educational Resources Information Center
Duyck, Wouter; Anseel, Frederik; Szmalec, Arnaud; Mestdagh, Pascal; Tavernier, Antoine; Hartsuiker, Robert J.
2008-01-01
In current cognitive psychology, naming latencies are commonly measured by electronic voice keys that detect when sound exceeds a certain amplitude threshold. However, recent research (e.g., K. Rastle & M. H. Davis, 2002) has shown that these devices are particularly inaccurate in precisely detecting acoustic onsets. In this article, the authors…
ERIC Educational Resources Information Center
Capewell, Carmel
2014-01-01
Glue ear, a condition resulting in intermittent hearing loss in young children, affects about 80% of young children under seven years old. About 60% of children will spend a third of their time unable to hear within normal thresholds. Teachers are unlikely to consider the sound quality in classrooms. In my research young people provided…
[Acoustical parameters of toys].
Harazin, Barbara
2010-01-01
Toys play an important role in the development of the sight and hearing concentration in children. They also support the development of manipulation, gently influence a child and excite its emotional activities. A lot of toys emit various sounds. The aim of the study was to assess sound levels produced by sound-emitting toys used by young children. Acoustical parameters of noise were evaluated for 16 sound-emitting plastic toys in laboratory conditions. The noise level was recorded at four different distances, 10, 20, 25 and 30 cm, from the toy. Measurements of A-weighted sound pressure levels and noise levels in octave band in the frequency range from 31.5 Hz to 16 kHz were performed at each distance. Taking into consideration the highest equivalent A-weighted sound levels produced by tested toys, they can be divided into four groups: below 70 dB (6 toys), from 70 to 74 dB (4 toys), from 75 to 84 dB (3 toys) and from 85 to 94 dB (3 toys). The majority of toys (81%) emitted dominant sound levels in octave band at the frequency range from 2 kHz to 4 kHz. Sound-emitting toys produce the highest acoustic energy at the frequency range of the highest susceptibility of the auditory system. Noise levels produced by some toys can be dangerous to children's hearing.
Abrams, Thad E; Lund, Brian C; Alexander, Bruce; Bernardy, Nancy C; Friedman, Matthew J
2015-01-01
Posttraumatic stress disorder (PTSD) is a high-priority treatment area for the Veterans Health Administration (VHA), and dissemination patterns of innovative, efficacious therapies can inform areas for potential improvement of diffusion efforts and quality prescribing. In this study, we replicated a prior examination of the period prevalence of prazosin use as a function of distance from Puget Sound, Washington, where prazosin was first tested as an effective treatment for PTSD and where prazosin use was previously shown to be much greater than in other parts of the United States. We tested the following three hypotheses related to prazosin geographic diffusion: (1) a positive geographical correlation exists between the distance from Puget Sound and the proportion of users treated according to a guideline recommended minimum therapeutic target dose (>/=6 mg/d), (2) an inverse geographic correlation exists between prazosin and benzodiazepine use, and (3) no geographical correlation exists between prazosin use and serotonin reuptake inhibitor/serotonin norepinephrine reuptake inhibitor (SSRI/SNRI) use. Among a national sample of veterans with PTSD, overall prazosin utilization increased from 5.5 to 14.8% from 2006 to 2012. During this time period, rates at the Puget Sound VHA location declined from 34.4 to 29.9%, whereas utilization rates at locations a minimum of 2,500 miles away increased from 3.0 to 12.8%. Rates of minimum target dosing fell from 42.6 to 34.6% at the Puget Sound location. In contrast, at distances of at least 2,500 miles from Puget Sound, minimum threshold dosing rates remained stable (range, 18.6 to 17.7%). No discernible association was demonstrated between SSRI/SNRI or benzodiazepine utilization and the geographic distance from Puget Sound. Minimal threshold dosing of prazosin correlated positively with increased diffusion of prazosin use, but there was still a distance diffusion gradient. Although prazosin adoption has improved, geographic differences persist in both prescribing rates and minimum target dosing. Importantly, these regional disparities appear to be limited to prazosin prescribing and are not meaningfully correlated with SSRI/SNRI and benzodiazepine use as indicators of PTSD prescribing quality.
Davy, John L
2012-08-01
The author has published equations for predicting the air borne sound transmission of double leaf cavity walls due to the structure borne sound transmission across the air cavity via (possibly resilient) line connections, but has never published the full derivation of these equations. The author also derived equations for the case when the connections are rigid point connections but has never used them or published them or their derivations. This paper will present the full derivation of the author's theory of the air borne sound transmission of double leaf cavity walls due to the structure borne sound transmission across the air cavity via point or line connections which are modeled as four pole networks. The theoretical results will be compared with experimental results on wooden stud cavity walls from the National Research Council of Canada because the screw spacing is given for these results. This enables connections via studs and screws to be modeled as point connections and avoids the need to make any assumptions about the compliance of the equivalent point or line connections.
Jones, Matthew D; Taylor, Janet L; Booth, John; Barry, Benjamin K
2016-01-01
Exercise-induced hypoalgesia is well described, but the underlying mechanisms are unclear. The aim of this study was to examine the effect of exercise on somatosensory evoked potentials, laser evoked potentials, pressure pain thresholds and heat pain thresholds. These were recorded before and after 3-min of isometric elbow flexion exercise at 40% of the participant's maximal voluntary force, or an equivalent period of rest. Exercise-induced hypoalgesia was confirmed in two experiments (Experiment 1-SEPs; Experiment 2-LEPs) by increased pressure pain thresholds at biceps brachii (24.3 and 20.6% increase in Experiment 1 and 2, respectively; both d > 0.84 and p < 0.001) and first dorsal interosseous (18.8 and 21.5% increase in Experiment 1 and 2, respectively; both d > 0.57 and p < 0.001). In contrast, heat pain thresholds were not significantly different after exercise (forearm: 10.8% increase, d = 0.35, p = 0.10; hand: 3.6% increase, d = 0.06, p = 0.74). Contrasting effects of exercise on the amplitude of laser evoked potentials (14.6% decrease, d = -0.42, p = 0.004) and somatosensory evoked potentials (10.9% increase, d = -0.02, p = 1) were also observed, while an equivalent period of rest showed similar habituation (laser evoked potential: 7.3% decrease, d = -0.25, p = 0.14; somatosensory evoked potential: 20.7% decrease, d = -0.32, p = 0.006). The differential response of pressure pain thresholds and heat pain thresholds to exercise is consistent with relative insensitivity of thermal nociception to the acute hypoalgesic effects of exercise. Conflicting effects of exercise on somatosensory evoked potentials and laser evoked potentials were observed. This may reflect non-nociceptive contributions to the somatosensory evoked potential, but could also indicate that peripheral nociceptors contribute to exercise-induced hypoalgesia.
Kastelein, Ronald A; Hoek, Lean; Gransier, Robin; Rambags, Martijn; Claeys, Naomi
2014-07-01
Safety criteria for underwater low-frequency active sonar sounds produced during naval exercises are needed to protect harbor porpoise hearing. As a first step toward defining criteria, a porpoise was exposed to sequences consisting of series of 1-s, 1-2 kHz sonar down-sweeps without harmonics (as fatiguing noise) at various combinations of average received sound pressure levels (SPLs; 144-179 dB re 1 μPa), exposure durations (1.9-240 min), and duty cycles (5%-100%). Hearing thresholds were determined for a narrow-band frequency-swept sine wave centered at 1.5 kHz before exposure to the fatiguing noise, and at 1-4, 4-8, 8-12, 48, 96, 144, and 1400 min after exposure, to quantify temporary threshold shifts (TTSs) and recovery of hearing. Results show that the inter-pulse interval of the fatiguing noise is an important parameter in determining the magnitude of noise-induced TTS. For the reported range of exposure combinations (duration and SPL), the energy of the exposure (i.e., cumulative sound exposure level; SELcum) can be used to predict the induced TTS, if the inter-pulse interval is known. Exposures with equal SELcum but with different inter-pulse intervals do not result in the same induced TTS.
Drake, D.E.; Cacchione, D.A.
1986-01-01
Bed shear stress was estimated using wave and current measurements obtained with the GEOPROBE bottom-tripod system during resuspension events in Norton Sound, Alaska, and on the northern California shelf. The boundary-layer model of Grant and Madsen (1979, Journal of Geophysical Research, 84, 1797-1808) was used to compute the bed shear stress under combined wave-generated and quasi-steady currents. Resuspension events were identified by sudden, large increases in light scattering at 1.9 m above the sea floor. The shear-stress values were used to compute the Shields parameter (??). The results for Norton Sound are in excellent agreement with the Shields threshold criterion; the data for the California shelf plot somewhat above the Shields threshold curve, though generally within the scatter envelope. Although the surface sediments in each area contain substantial fine-grained fractions (mean diameters were 0.007 cm in Norton Sound and 0.002 cm on the California shelf), the results do not indicate significant cohesion, because the sediment was entrained at bed shear-stress values close to those predicted by the modified Shields curve for cohesionless fine-grained particles. We suspect that frequent wave stirring and observed plowing of the surface sediment by benthonic animals maintain a high water content and contribute to the ease with which these materials are resuspended. ?? 1986.
A differentially amplified motion in the ear for near-threshold sound detection
Chen, Fangyi; Zha, Dingjun; Fridberger, Anders; Zheng, Jiefu; Choudhury, Niloy; Jacques, Steven L.; Wang, Ruikang K.; Shi, Xiaorui; Nuttall, Alfred L.
2011-01-01
The ear is a remarkably sensitive pressure fluctuation detector. In guinea pigs, behavioral measurements indicate a minimum detectable sound pressure of ~20 μPa at 16 kHz. Such faint sounds produce 0.1 nm basilar membrane displacements, a distance smaller than conformational transitions in ion channels. It seems that noise within the auditory system would swamp such tiny motions, making weak sounds imperceptible. Here, a new mechanism contributing to a resolution of this problem is proposed and validated through direct measurement. We hypothesize that vibration at the apical end of hair cells is enhanced compared to the commonly measured basilar membrane side. Using in vivo optical coherence tomography, we demonstrated that apical-side vibrations peak at a higher frequency, had different timing, and were enhanced compared to the basilar membrane. These effects depend nonlinearly on the stimulus level. The timing difference and enhancement are important for explaining how the noise problem is circumvented. PMID:21602821
Merchant, Nathan D; Witt, Matthew J; Blondel, Philippe; Godley, Brendan J; Smith, George H
2012-07-01
Underwater noise from shipping is a growing presence throughout the world's oceans, and may be subjecting marine fauna to chronic noise exposure with potentially severe long-term consequences. The coincidence of dense shipping activity and sensitive marine ecosystems in coastal environments is of particular concern, and noise assessment methodologies which describe the high temporal variability of sound exposure in these areas are needed. We present a method of characterising sound exposure from shipping using continuous passive acoustic monitoring combined with Automatic Identification System (AIS) shipping data. The method is applied to data recorded in Falmouth Bay, UK. Absolute and relative levels of intermittent ship noise contributions to the 24-h sound exposure level are determined using an adaptive threshold, and the spatial distribution of potential ship sources is then analysed using AIS data. This technique can be used to prioritize shipping noise mitigation strategies in coastal marine environments. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Van Hirtum, A.; Berckmans, D.
2003-09-01
A natural acoustic indicator of animal welfare is the appearance (or absence) of coughing in the animal habitat. A sound-database of 5319 individual sounds including 2034 coughs was collected on six healthy piglets containing both animal vocalizations and background noises. Each of the test animals was repeatedly placed in a laboratory installation where coughing was induced by nebulization of citric acid. A two-class classification into 'cough' or 'other' was performed by the application of a distance function to a fast Fourier spectral sound analysis. This resulted in a positive cough recognition of 92%. For the whole sound-database however there was a misclassification of 21%. As spectral information up to 10000 Hz is available, an improved overall classification on the same database is obtained by applying the distance function to nine frequency ranges and combining the achieved distance-values in fuzzy rules. For each frequency range clustering threshold is determined by fuzzy c-means clustering.
Houser, Dorian S; Finneran, James J
2006-09-01
Variable stimulus presentation methods are used in auditory evoked potential (AEP) estimates of cetacean hearing sensitivity, each of which might affect stimulus reception and hearing threshold estimates. This study quantifies differences in underwater hearing thresholds obtained by AEP and behavioral means. For AEP estimates, a transducer embedded in a suction cup (jawphone) was coupled to the dolphin's lower jaw for stimulus presentation. Underwater AEP thresholds were obtained for three dolphins in San Diego Bay and for one dolphin in a quiet pool. Thresholds were estimated from the envelope following response at carrier frequencies ranging from 10 to 150 kHz. One animal, with an atypical audiogram, demonstrated significantly greater hearing loss in the right ear than in the left. Across test conditions, the range and average difference between AEP and behavioral threshold estimates were consistent with published comparisons between underwater behavioral and in-air AEP thresholds. AEP thresholds for one animal obtained in-air and in a quiet pool demonstrated a range of differences of -10 to 9 dB (mean = 3 dB). Results suggest that for the frequencies tested, the presentation of sound stimuli through a jawphone, underwater and in-air, results in acceptable differences to AEP threshold estimates.
The effect of cockpit noise on the temporary threshold shift of Cessna 172SP flight instructors
NASA Astrophysics Data System (ADS)
Bellini, Andrew Robert
The purpose of this thesis was to study the temporary threshold shift of general aviation flight instructors resulting from their working environment. Exposure to noise before a temporary threshold shift completely recovers can cause a permanent threshold shift with no possibility of recovery, resulting in permanent hearing loss. A result showing minimal to no temporary threshold shift would indicate that hearing personal protective equipment is working properly. This study used sound-level measurements, and audiometric testing, together with survey data to determine whether or not flight instructors were at risk for potential hearing impairment due to temporary threshold shift. Independent t-tests and descriptive statistics were used in analyzing the data. It was determined that there was a difference in temporary threshold shift based on the number of hours a flight instructor flies in a Cessna 172SP for only one frequency - 2000Hz in the left ear. All other frequencies tested in both ears showed no difference. Because there was a very low mean temporary threshold shift at 2000Hz in the left ear and no differences shown for all other frequencies in both ears, it was concluded that there was no need to improve or require additional hearing personal protective equipment, or to require decreased exposure times to aircraft noise.
Kok, Annebelle C M; Engelberts, J Pamela; Kastelein, Ronald A; Helder-Hoek, Lean; Van de Voorde, Shirley; Visser, Fleur; Slabbekoorn, Hans
2018-02-01
The continuing rise in underwater sound levels in the oceans leads to disturbance of marine life. It is thought that one of the main impacts of sound exposure is the alteration of foraging behaviour of marine species, for example by deterring animals from a prey location, or by distracting them while they are trying to catch prey. So far, only limited knowledge is available on both mechanisms in the same species. The harbour porpoise (Phocoena phocoena) is a relatively small marine mammal that could quickly suffer fitness consequences from a reduction of foraging success. To investigate effects of anthropogenic sound on their foraging efficiency, we tested whether experimentally elevated sound levels would deter two captive harbour porpoises from a noisy pool into a quiet pool (Experiment 1) and reduce their prey-search performance, measured as prey-search time in the noisy pool (Experiment 2). Furthermore, we tested the influence of the temporal structure and amplitude of the sound on the avoidance response of both animals. Both individuals avoided the pool with elevated sound levels, but they did not show a change in search time for prey when trying to find a fish hidden in one of three cages. The combination of temporal structure and SPL caused variable patterns. When the sound was intermittent, increased SPL caused increased avoidance times. When the sound was continuous, avoidance was equal for all SPLs above a threshold of 100 dB re 1 μPa. Hence, we found no evidence for an effect of sound exposure on search efficiency, but sounds of different temporal patterns did cause spatial avoidance with distinct dose-response patterns. Copyright © 2017 Elsevier Ltd. All rights reserved.
Neutron scattered dose equivalent to a fetus from proton radiotherapy of the mother.
Mesoloras, Geraldine; Sandison, George A; Stewart, Robert D; Farr, Jonathan B; Hsi, Wen C
2006-07-01
Scattered neutron dose equivalent to a representative point for a fetus is evaluated in an anthropomorphic phantom of the mother undergoing proton radiotherapy. The effect on scattered neutron dose equivalent to the fetus of changing the incident proton beam energy, aperture size, beam location, and air gap between the beam delivery snout and skin was studied for both a small field snout and a large field snout. Measurements of the fetus scattered neutron dose equivalent were made by placing a neutron bubble detector 10 cm below the umbilicus of an anthropomorphic Rando phantom enhanced by a wax bolus to simulate a second trimester pregnancy. The neutron dose equivalent in milliSieverts (mSv) per proton treatment Gray increased with incident proton energy and decreased with aperture size, distance of the fetus representative point from the field edge, and increasing air gap. Neutron dose equivalent to the fetus varied from 0.025 to 0.450 mSv per proton Gray for the small field snout and from 0.097 to 0.871 mSv per proton Gray for the large field snout. There is likely to be no excess risk to the fetus of severe mental retardation for a typical proton treatment of 80 Gray to the mother since the scattered neutron dose to the fetus of 69.7 mSv is well below the lower confidence limit for the threshold of 300 mGy observed for the occurrence of severe mental retardation in prenatally exposed Japanese atomic bomb survivors. However, based on the linear no threshold hypothesis, and this same typical treatment for the mother, the excess risk to the fetus of radiation induced cancer death in the first 10 years of life is 17.4 per 10,000 children.
Auditory brainstem response to complex sounds predicts self-reported speech-in-noise performance.
Anderson, Samira; Parbery-Clark, Alexandra; White-Schwoch, Travis; Kraus, Nina
2013-02-01
To compare the ability of the auditory brainstem response to complex sounds (cABR) to predict subjective ratings of speech understanding in noise on the Speech, Spatial, and Qualities of Hearing Scale (SSQ; Gatehouse & Noble, 2004) relative to the predictive ability of the Quick Speech-in-Noise test (QuickSIN; Killion, Niquette, Gudmundsen, Revit, & Banerjee, 2004) and pure-tone hearing thresholds. Participants included 111 middle- to older-age adults (range = 45-78) with audiometric configurations ranging from normal hearing levels to moderate sensorineural hearing loss. In addition to using audiometric testing, the authors also used such evaluation measures as the QuickSIN, the SSQ, and the cABR. Multiple linear regression analysis indicated that the inclusion of brainstem variables in a model with QuickSIN, hearing thresholds, and age accounted for 30% of the variance in the Speech subtest of the SSQ, compared with significantly less variance (19%) when brainstem variables were not included. The authors' results demonstrate the cABR's efficacy for predicting self-reported speech-in-noise perception difficulties. The fact that the cABR predicts more variance in self-reported speech-in-noise (SIN) perception than either the QuickSIN or hearing thresholds indicates that the cABR provides additional insight into an individual's ability to hear in background noise. In addition, the findings underscore the link between the cABR and hearing in noise.
Duarte, Alexandre Scalli Mathias; Ng, Ronny Tah Yen; de Carvalho, Guilherme Machado; Guimarães, Alexandre Caixeta; Pinheiro, Laiza Araujo Mohana; Costa, Everardo Andrade da; Gusmão, Reinaldo Jordão
2015-01-01
The clinical evaluation of subjects with occupational noise exposure has been difficult due to the discrepancy between auditory complaints and auditory test results. This study aimed to evaluate the contralateral acoustic reflex thresholds of workers exposed to high levels of noise, and to compare these results to the subjects' auditory complaints. This clinical retrospective study evaluated 364 workers between 1998 and 2005; their contralateral acoustic reflexes were compared to auditory complaints, age, and noise exposure time by chi-squared, Fisher's, and Spearman's tests. The workers' age ranged from 18 to 50 years (mean=39.6), and noise exposure time from one to 38 years (mean=17.3). We found that 15.1% (55) of the workers had bilateral hearing loss, 38.5% (140) had bilateral tinnitus, 52.8% (192) had abnormal sensitivity to loud sounds, and 47.2% (172) had speech recognition impairment. The variables hearing loss, speech recognition impairment, tinnitus, age group, and noise exposure time did not show relationship with acoustic reflex thresholds; however, all complaints demonstrated a statistically significant relationship with Metz recruitment at 3000 and 4000Hz bilaterally. There was no significance relationship between auditory complaints and acoustic reflexes. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Speech training alters consonant and vowel responses in multiple auditory cortex fields
Engineer, Crystal T.; Rahebi, Kimiya C.; Buell, Elizabeth P.; Fink, Melyssa K.; Kilgard, Michael P.
2015-01-01
Speech sounds evoke unique neural activity patterns in primary auditory cortex (A1). Extensive speech sound discrimination training alters A1 responses. While the neighboring auditory cortical fields each contain information about speech sound identity, each field processes speech sounds differently. We hypothesized that while all fields would exhibit training-induced plasticity following speech training, there would be unique differences in how each field changes. In this study, rats were trained to discriminate speech sounds by consonant or vowel in quiet and in varying levels of background speech-shaped noise. Local field potential and multiunit responses were recorded from four auditory cortex fields in rats that had received 10 weeks of speech discrimination training. Our results reveal that training alters speech evoked responses in each of the auditory fields tested. The neural response to consonants was significantly stronger in anterior auditory field (AAF) and A1 following speech training. The neural response to vowels following speech training was significantly weaker in ventral auditory field (VAF) and posterior auditory field (PAF). This differential plasticity of consonant and vowel sound responses may result from the greater paired pulse depression, expanded low frequency tuning, reduced frequency selectivity, and lower tone thresholds, which occurred across the four auditory fields. These findings suggest that alterations in the distributed processing of behaviorally relevant sounds may contribute to robust speech discrimination. PMID:25827927
Influence of double stimulation on sound-localization behavior in barn owls.
Kettler, Lutz; Wagner, Hermann
2014-12-01
Barn owls do not immediately approach a source after they hear a sound, but wait for a second sound before they strike. This represents a gain in striking behavior by avoiding responses to random incidents. However, the first stimulus is also expected to change the threshold for perceiving the subsequent second sound, thus possibly introducing some costs. We mimicked this situation in a behavioral double-stimulus paradigm utilizing saccadic head turns of owls. The first stimulus served as an adapter, was presented in frontal space, and did not elicit a head turn. The second stimulus, emitted from a peripheral source, elicited the head turn. The time interval between both stimuli was varied. Data obtained with double stimulation were compared with data collected with a single stimulus from the same positions as the second stimulus in the double-stimulus paradigm. Sound-localization performance was quantified by the response latency, accuracy, and precision of the head turns. Response latency was increased with double stimuli, while accuracy and precision were decreased. The effect depended on the inter-stimulus interval. These results suggest that waiting for a second stimulus may indeed impose costs on sound localization by adaptation and this reduces the gain obtained by waiting for a second stimulus.
Natural and anthropogenic events influence the soundscapes of four bays on Hawaii Island.
Heenehan, Heather L; Van Parijs, Sofie M; Bejder, Lars; Tyne, Julian A; Southall, Brandon L; Southall, Hugh; Johnston, David W
2017-11-15
The soundscapes of four bays along the Kona Coast of Hawaii Island were monitored between January 2011 and March 2013. Equivalent, unweighted sound pressure levels within standard 1/3rd-octave bands (dB re: 1μPa) were calculated for each recording. Sound levels increased at night and were lowest during the daytime when spinner dolphins use the bays to rest. A tsunami provided an opportunity to monitor the soundscape with little anthropogenic component. We detected a decrease in sound levels and variability in one of the busiest bays. During the daytime in the 3.15kHz 1/3rd octave band, we detected 92 loud outliers from vessels, aquaculture, and military mid-frequency active sonar. During one military mid-frequency active sonar event sound levels reached 45.8dB above median ambient noise levels. The differences found in the bays illustrate the importance of understanding soundscapes to effectively manage noise pollution in marine ecosystems. Copyright © 2017 Elsevier Ltd. All rights reserved.
Holikachuk Noun Dictionary (Preliminary).
ERIC Educational Resources Information Center
Kari, James, Comp.; And Others
This dictionary contains lists of nouns in the Holikachuk Athabaskan language as spoken by about twenty people, most of whom live in the village of Grayling, Alaska. The Holikachuk alphabet and sound system are presented. The nouns with English equivalents are listed according to the following categories: animals, fish, insects, birds, plants,…
Theater Instruction via Interactive Television.
ERIC Educational Resources Information Center
Merrion, Margaret
1992-01-01
Although experiencing theater through videotape is not equivalent to experiencing live theater, the magic of theater and live instruction was not entirely lost when one off-campus student transferred from classroom to off-campus viewing for a semester. Concentration on graphics became more important, and lighting and sound could be more easily…
Code of Federal Regulations, 2011 CFR
2011-04-01
... the natural and mechanical sources and human activity, considered to be usually present in a... the period under consideration. (d) L10(h). The hourly value of L10. (e) Leq—the equivalent steady... sound level during the same time period. (f) Leq(h). The hourly value of Leq. (g) Traffic noise impacts...
Radiological protection and medical dosimetry for the Skylab crewmen
NASA Technical Reports Server (NTRS)
Bailey, J. V.; Hoffman, R. A.; English, R. A.
1977-01-01
Dosimetry results for Skylab crewmembers show that the Skylab 4 crewmen received the highest dose equivalents but remained well within the established limits for Skylab missions below the threshold of significant clinical effects. These dose equivalents apply specificially to long term effects such as general life shortening, increased neoplasm incidence, and cataract production. A Skylab crewman could fly a mission comparable to one 84-day Skylab 4 mission per year for 50 years before exceeding these career limits.
Neural representation of consciously imperceptible speech sound differences.
Allen, J; Kraus, N; Bradlow, A
2000-10-01
The concept of subliminal perception has been a subject of interest and controversy for decades. Of interest in the present investigation was whether a neurophysiologic index of stimulus change could be elicited to speech sound contrasts that were consciously indiscriminable. The stimuli were chosen on the basis of each individual subject's discrimination threshold. The speech stimuli (which varied along an F3 onset frequency continuum from /da/ to /ga/) were synthesized so that the acoustical properties of the stimuli could be tightly controlled. Subthreshold and suprathreshold stimuli were chosen on the basis of behavioral ability demonstrated during psychophysical testing. A significant neural representation of stimulus change, reflected by the mismatch negativity response, was obtained in all but 1 subject in response to subthreshold stimuli. Grand average responses differed significantly from responses obtained in a control condition consisting of physiologic responses elicited by physically identical stimuli. Furthermore, responses to suprathreshold stimuli (close to threshold) did not differ significantly from subthreshold responses with respect to latency, amplitude, or area. These results suggest that neural representation of consciously imperceptible stimulus differences occurs and that this representation occurs at a preattentive level.
Flow noise of an underwater vector sensor embedded in a flexible towed array.
Korenbaum, Vladimir I; Tagiltsev, Alexander A
2012-05-01
The objective of this work is to simulate the flow noise of a vector sensor embedded in a flexible towed array. The mathematical model developed, based on long-wavelength analysis of the inner space of a cylindrical multipole source, predicts the reduction of the flow noise of a vector sensor embedded in an underwater flexible towed array by means of intensimetric processing (cross-spectral density calculation of oscillatory velocity and sound-pressure-sensor responses). It is found experimentally that intensimetric processing results in flow noise reduction by 12-25 dB at mean levels and by 10-30 dB in fluctuations compared to a squared oscillatory velocity channel. The effect of flow noise suppression in the intensimetry channel relative to a squared sound pressure channel is observed, but only for frequencies above the threshold. These suppression values are 10-15 dB at mean noise levels and 3-6 dB in fluctuations. At towing velocities of 1.5-3 ms(-1) and an accumulation time of 98.3 s, the threshold frequency in fluctuations is between 30 and 45 Hz.
Spectral envelope sensitivity of musical instrument sounds.
Gunawan, David; Sen, D
2008-01-01
It is well known that the spectral envelope is a perceptually salient attribute in musical instrument timbre perception. While a number of studies have explored discrimination thresholds for changes to the spectral envelope, the question of how sensitivity varies as a function of center frequency and bandwidth for musical instruments has yet to be addressed. In this paper a two-alternative forced-choice experiment was conducted to observe perceptual sensitivity to modifications made on trumpet, clarinet and viola sounds. The experiment involved attenuating 14 frequency bands for each instrument in order to determine discrimination thresholds as a function of center frequency and bandwidth. The results indicate that perceptual sensitivity is governed by the first few harmonics and sensitivity does not improve when extending the bandwidth any higher. However, sensitivity was found to decrease if changes were made only to the higher frequencies and continued to decrease as the distorted bandwidth was widened. The results are analyzed and discussed with respect to two other spectral envelope discrimination studies in the literature as well as what is predicted from a psychoacoustic model.
[Sound improves distinction of low intensities of light in the visual cortex of a rabbit].
Polianskiĭ, V B; Alymkulov, D E; Evtikhin, D V; Chernyshev, B V
2011-01-01
Electrodes were implanted into cranium above the primary visual cortex of four rabbits (Orictolagus cuniculus). At the first stage, visual evoked potentials (VEPs) were recorded in response to substitution of threshold visual stimuli (0.28 and 0.31 cd/m2). Then the sound (2000 Hz, 84 dB, duration 40 ms) was added simultaneously to every visual stimulus. Single sounds (without visual stimuli) did not produce a VEP-response. It was found that the amplitude ofVEP component N1 (85-110 ms) in response to complex stimuli (visual and sound) increased 1.6 times as compared to "simple" visual stimulation. At the second stage, paired substitutions of 8 different visual stimuli (range 0.38-20.2 cd/m2) by each other were performed. Sensory spaces of intensity were reconstructed on the basis of factor analysis. Sensory spaces of complexes were reconstructed in a similar way for simultaneous visual and sound stimulation. Comparison of vectors representing the stimuli in the spaces showed that the addition of a sound led to a 1.4-fold expansion of the space occupied by smaller intensities (0.28; 1.02; 3.05; 6.35 cd/m2). Also, the addition of the sound led to an arrangement of intensities in an ascending order. At the same time, the sound 1.33-times narrowed the space of larger intensities (8.48; 13.7; 16.8; 20.2 cd/m2). It is suggested that the addition of a sound improves a distinction of smaller intensities and impairs a dis- tinction of larger intensities. Sensory spaces revealed by complex stimuli were two-dimensional. This fact can be a consequence of integration of sound and light in a unified complex at simultaneous stimulation.
226-237 E. Ontario, April 2016, Lindsay Light Radiological Survey
Field gamma measurements did not exceed the field instrument threshold equivalent to the USEPA removal actionlevel and ranged from a minimum of 6,000 cpm to a maximum of approximately 9,000 cpm unshielded.
330-334 E. Ontario, April 2016, Lindsay Light Radiological Survey
Field gamma measurement did not exceed the field instrument threshold equivalent to the USEPA removal actionlevel and ranged from a minimum of 5,700 cpm to a maximum of approximately 13,100 cpm unshielded.
Pitch discrimination by ferrets for simple and complex sounds.
Walker, Kerry M M; Schnupp, Jan W H; Hart-Schnupp, Sheelah M B; King, Andrew J; Bizley, Jennifer K
2009-09-01
Although many studies have examined the performance of animals in detecting a frequency change in a sequence of tones, few have measured animals' discrimination of the fundamental frequency (F0) of complex, naturalistic stimuli. Additionally, it is not yet clear if animals perceive the pitch of complex sounds along a continuous, low-to-high scale. Here, four ferrets (Mustela putorius) were trained on a two-alternative forced choice task to discriminate sounds that were higher or lower in F0 than a reference sound using pure tones and artificial vowels as stimuli. Average Weber fractions for ferrets on this task varied from approximately 20% to 80% across references (200-1200 Hz), and these fractions were similar for pure tones and vowels. These thresholds are approximately ten times higher than those typically reported for other mammals on frequency change detection tasks that use go/no-go designs. Naive human listeners outperformed ferrets on the present task, but they showed similar effects of stimulus type and reference F0. These results suggest that while non-human animals can be trained to label complex sounds as high or low in pitch, this task may be much more difficult for animals than simply detecting a frequency change.
Cheng, Liang; Wang, Shao-Hui; Peng, Kang; Liao, Xiao-Mei
2017-01-01
Most citizen people are exposed daily to environmental noise at moderate levels with a short duration. The aim of the present study was to determine the effects of daily short-term exposure to moderate noise on sound level processing in the auditory midbrain. Sound processing properties of auditory midbrain neurons were recorded in anesthetized mice exposed to moderate noise (80 dB SPL, 2 h/d for 6 weeks) and were compared with those from age-matched controls. Neurons in exposed mice had a higher minimum threshold and maximum response intensity, a longer first spike latency, and a higher slope and narrower dynamic range for rate level function. However, these observed changes were greater in neurons with the best frequency within the noise exposure frequency range compared with those outside the frequency range. These sound processing properties also remained abnormal after a 12-week period of recovery in a quiet laboratory environment after completion of noise exposure. In conclusion, even daily short-term exposure to moderate noise can cause long-term impairment of sound level processing in a frequency-specific manner in auditory midbrain neurons.
Amplitude modulation detection by human listeners in sound fields.
Zahorik, Pavel; Kim, Duck O; Kuwada, Shigeyuki; Anderson, Paul W; Brandewie, Eugene; Srinivasan, Nirmal
2011-10-01
The temporal modulation transfer function (TMTF) approach allows techniques from linear systems analysis to be used to predict how the auditory system will respond to arbitrary patterns of amplitude modulation (AM). Although this approach forms the basis for a standard method of predicting speech intelligibility based on estimates of the acoustical modulation transfer function (MTF) between source and receiver, human sensitivity to AM as characterized by the TMTF has not been extensively studied under realistic listening conditions, such as in reverberant sound fields. Here, TMTFs (octave bands from 2 - 512 Hz) were obtained in 3 listening conditions simulated using virtual auditory space techniques: diotic, anechoic sound field, reverberant room sound field. TMTFs were then related to acoustical MTFs estimated using two different methods in each of the listening conditions. Both diotic and anechoic data were found to be in good agreement with classic results, but AM thresholds in the reverberant room were lower than predictions based on acoustical MTFs. This result suggests that simple linear systems techniques may not be appropriate for predicting TMTFs from acoustical MTFs in reverberant sound fields, and may be suggestive of mechanisms that functionally enhance modulation during reverberant listening.
Cheng, Liang; Wang, Shao-Hui; Peng, Kang
2017-01-01
Most citizen people are exposed daily to environmental noise at moderate levels with a short duration. The aim of the present study was to determine the effects of daily short-term exposure to moderate noise on sound level processing in the auditory midbrain. Sound processing properties of auditory midbrain neurons were recorded in anesthetized mice exposed to moderate noise (80 dB SPL, 2 h/d for 6 weeks) and were compared with those from age-matched controls. Neurons in exposed mice had a higher minimum threshold and maximum response intensity, a longer first spike latency, and a higher slope and narrower dynamic range for rate level function. However, these observed changes were greater in neurons with the best frequency within the noise exposure frequency range compared with those outside the frequency range. These sound processing properties also remained abnormal after a 12-week period of recovery in a quiet laboratory environment after completion of noise exposure. In conclusion, even daily short-term exposure to moderate noise can cause long-term impairment of sound level processing in a frequency-specific manner in auditory midbrain neurons. PMID:28589040
Sound localization in common vampire bats: Acuity and use of the binaural time cue by a small mammal
Heffner, Rickye S.; Koay, Gimseong; Heffner, Henry E.
2015-01-01
Passive sound-localization acuity and the ability to use binaural time and intensity cues were determined for the common vampire bat (Desmodus rotundus). The bats were tested using a conditioned suppression/avoidance procedure in which they drank defibrinated blood from a spout in the presence of sounds from their right, but stopped drinking (i.e., broke contact with the spout) whenever a sound came from their left, thereby avoiding a mild shock. The mean minimum audible angle for three bats for a 100-ms noise burst was 13.1°—within the range of thresholds for other bats and near the mean for mammals. Common vampire bats readily localized pure tones of 20 kHz and higher, indicating they could use interaural intensity-differences. They could also localize pure tones of 5 kHz and lower, thereby demonstrating the use of interaural time-differences, despite their very small maximum interaural distance of 60 μs. A comparison of the use of locus cues among mammals suggests several implications for the evolution of sound localization and its underlying anatomical and physiological mechanisms. PMID:25618037
The sound insulations of studio doors. Part 2: Door seals
NASA Astrophysics Data System (ADS)
Plumb, G. D.; Clark, R.
The acoustic performances of a range of proprietary acoustic door seals were measured in the Transmission Suite. The seals were fitted to a standard BBC lead-cored door hung in a purpose-built blockwork wall. As a result of the work, suitable plant-on magnetic perimeter seals and drop-down threshold seals are recommended. The use of these seals will simplify the existing door frame design and should reduce costs without compromising the acoustic performances. The sound insulations were also measured of a range of door blanks with the intention of improving the performances. This work is documented in a companion Report (BBC RD 1994/14).
A laboratory study of subjective annoyance response to sonic booms and aircraft flyovers
NASA Technical Reports Server (NTRS)
Leatherwood, Jack D.; Sullivan, Brenda M.
1994-01-01
Three experiments were conducted to determine subjective equivalence of aircraft subsonic flyover noise and sonic booms. Two of the experiments were conducted in a loudspeaker-driven sonic boom simulator, and the third in a large room containing conventional loudspeakers. The sound generation system of the boom simulator had a frequency response extending to very low frequencies (about 1 Hz) whereas the large room loudspeakers were limited to about 20 Hz. Subjective equivalence between booms and flyovers was quantified in terms of the difference between the noise level of a boom and that of a flyover when the two were judged equally annoying. Noise levels were quantified in terms of the following noise descriptors: Perceived Level (PL), Perceived Noise Level (PNL), C-weighted sound exposure level (SELC), and A-weighted sound exposure level (SELA). Results from the present study were compared, where possible, to similar results obtained in other studies. Results showed that noise level differences depended upon the descriptor used, specific boom and aircraft noise events being compared and, except for the PNL descriptor, varied between the simulator and large room. Comparison of noise level differences obtained in the present study with those of other studies indicated good agreement across studies only for the PNL and SELA descriptors. Comparison of the present results with assessments of community response to high-energy impulsive sounds made by Working Group 84 of the National Research Council's Committee on Hearing, Bioacoustics, and Biomechanics (CHABA) showed good agreement when boom/flyover noise level differences were based on SELA. However, noise level differences obtained by CHABA using SELA for aircraft flyovers and SELC for booms were not in agreement with results obtained in the present study.
Assessment and analysis of noise pollution in Biskra public gardens (Algeria)
NASA Astrophysics Data System (ADS)
Bouzir, Tallal Abdel Karim; Zemmouri, Noureddine; Berkouk, Djihed
2018-05-01
A quantitative evaluation of noise pollution in the public gardens of Biskra, Algeria, was carried out in this research. The equivalent sound level (leq1min) was measured in 27 points distributed over the seven main gardens of the city. The results of the measurements show that the measured level of sound intensity varies from 56.38 dB in the Landon garden to 62.55 dB in the Larbi Ben Mhidi garden. By comparing, the measured values with the noise limit values recommended by the national legislation, the standards of the World Health Organization and the United States Environmental Protection Agency; it is clear that the sound environment in these public gardens do not comply with the recognized standards of acoustic comfort. The gardens' spaces are heavily over-exposed to traffic noise resulting in high levels acoustic pollution.
Statistical mechanics of self-driven Carnot cycles.
Smith, E
1999-10-01
The spontaneous generation and finite-amplitude saturation of sound, in a traveling-wave thermoacoustic engine, are derived as properties of a second-order phase transition. It has previously been argued that this dynamical phase transition, called "onset," has an equivalent equilibrium representation, but the saturation mechanism and scaling were not computed. In this work, the sound modes implementing the engine cycle are coarse-grained and statistically averaged, in a partition function derived from microscopic dynamics on criteria of scale invariance. Self-amplification performed by the engine cycle is introduced through higher-order modal interactions. Stationary points and fluctuations of the resulting phenomenological Lagrangian are analyzed and related to background dynamical currents. The scaling of the stable sound amplitude near the critical point is derived and shown to arise universally from the interaction of finite-temperature disorder, with the order induced by self-amplification.
Long-time cavitation threshold of silica water mixture under acoustic drive
NASA Astrophysics Data System (ADS)
Bussonniére, Adrien; Liu, Qingxia; Tsai, Peichun Amy
2017-11-01
The low cavitation threshold of water observed experimentally has been attributed to the presence of pre-existing tiny bubbles stabilized by impurities. However, the origin and stability of these cavitation nuclei remain unresolved. We therefore investigate the long-time cavitation evolution of water seeded with micron-sized silica particles under the influences of several parameters. Experimentally, cavitation is induced by a High Intensity Focused Ultrasound and subsequently detected by monitoring the backscattered sound. Degassed or aerated solutions of different concentrations are subjected to acoustic pulses (with the amplitude ranging from 0.1 to 1.7 MPa and a fixed repetition frequency between 0.1 and 6.5 Hz). The cavitation threshold was measured by fitting the cavitation probability curve, averaged over 1000 pulses. Surprisingly, our results shown that the cavitation threshold stabilizes at a reproducible value after a few thousand pulses. Moreover, this long-time threshold was found to decrease with increasing particle concentration, pulse period, and initial oxygen level. In contrast to the depletion of nuclei expected under long acoustic cavitation, the results suggest stabilized nuclei population depending on concentration, oxygen level, and driving period.
Acoustic pressure waves induced in human heads by RF pulses from high-field MRI scanners.
Lin, James C; Wang, Zhangwei
2010-04-01
The current evolution toward greater image resolution from magnetic resonance image (MRI) scanners has prompted the exploration of higher strength magnetic fields and use of higher levels of radio frequencies (RFs). Auditory perception of RF pulses by humans has been reported during MRI with head coils. It has shown that the mechanism of interaction for the auditory effect is caused by an RF pulse-induced thermoelastic pressure wave inside the head. We report a computational study of the intensity and frequency of thermoelastic pressure waves generated by RF pulses in the human head inside high-field MRI and clinical scanners. The U.S. Food and Drug Administration (U.S. FDA) guides limit the local specific absorption rate (SAR) in the body-including the head-to 8 W kg(-1). We present results as functions of SAR and show that for a given SAR the peak acoustic pressures generated in the anatomic head model were essentially the same at 64, 300, and 400 MHz (1.5, 7.0, and 9.4 T). Pressures generated in the anatomic head are comparable to the threshold pressure of 20 mPa for sound perception by humans at the cochlea for 4 W kg(-1). Moreover, results indicate that the peak acoustic pressure in the brain is only 2 to 3 times the auditory threshold at the U.S. FDA guideline of 8 W kg(-1). Even at a high SAR of 20 W kg(-1), where the acoustic pressure in the brain could be more than 7 times the auditory threshold, the sound pressure levels would not be more than 17 db above threshold of perception at the cochlea.
Effects of sound intensity on temporal properties of inhibition in the pallid bat auditory cortex.
Razak, Khaleel A
2013-01-01
Auditory neurons in bats that use frequency modulated (FM) sweeps for echolocation are selective for the behaviorally-relevant rates and direction of frequency change. Such selectivity arises through spectrotemporal interactions between excitatory and inhibitory components of the receptive field. In the pallid bat auditory system, the relationship between FM sweep direction/rate selectivity and spectral and temporal properties of sideband inhibition have been characterized. Of note is the temporal asymmetry in sideband inhibition, with low-frequency inhibition (LFI) exhibiting faster arrival times compared to high-frequency inhibition (HFI). Using the two-tone inhibition over time (TTI) stimulus paradigm, this study investigated the interactions between two sound parameters in shaping sideband inhibition: intensity and time. Specifically, the impact of changing relative intensities of the excitatory and inhibitory tones on arrival time of inhibition was studied. Using this stimulation paradigm, single unit data from the auditory cortex of pentobarbital-anesthetized cortex show that the threshold for LFI is on average ~8 dB lower than HFI. For equal intensity tones near threshold, LFI is stronger than HFI. When the inhibitory tone intensity is increased further from threshold, the strength asymmetry decreased. The temporal asymmetry in LFI vs. HFI arrival time is strongest when the excitatory and inhibitory tones are of equal intensities or if excitatory tone is louder. As inhibitory tone intensity is increased, temporal asymmetry decreased suggesting that the relative magnitude of excitatory and inhibitory inputs shape arrival time of inhibition and FM sweep rate and direction selectivity. Given that most FM bats use downward sweeps as echolocation calls, a similar asymmetry in threshold and strength of LFI vs. HFI may be a general adaptation to enhance direction selectivity while maintaining sweep-rate selective responses to downward sweeps.
Noise in contemporary neonatal intensive care.
Williams, Amber L; van Drongelen, Wim; Lasky, Robert E
2007-05-01
Weekly sound surveys (n = 63) were collected, using 5 s sampling intervals, for two modern neonatal intensive care units (NICUs). Median weekly equivalent sound pressure levels (LEQ) for NICU A ranged from 61 to 63 dB (A weighted), depending on the level of care. NICU B L(EQ) measurements ranged from 55 to 60 dB (A weighted). NICU B was recently built with a focus on sound abatement, explaining much of the difference between the two NICUs. Sound levels exceeded 45 dB (A weighted), recommended by the American Academy of Pediatrics, more than 70% of the time for all levels of care. Hourly L(EQ)s below 50 dB (A weighted) and hourly L10s below 55 dB (A weighted), recommended by the Sound Study Group (SSG) of the National Resource Center, were also exceeded in more than 70% of recorded samples. A third SSG recommendation, that the 1 s L(MAX), should not exceed 70 dB (A weighted), was exceeded relatively infrequently (< 11% of the time). Peak impulse measurements exceeded 90 dB for 6.3% of 5 s samples recorded from NICU A and 2.8% of NICU B samples. Twenty-four h periodicities in sound levels as a function of regular staff activities were apparent, but short-term variability was considerable.
Using listening difficulty ratings of conditions for speech communication in rooms
NASA Astrophysics Data System (ADS)
Sato, Hiroshi; Bradley, John S.; Morimoto, Masayuki
2005-03-01
The use of listening difficulty ratings of speech communication in rooms is explored because, in common situations, word recognition scores do not discriminate well among conditions that are near to acceptable. In particular, the benefits of early reflections of speech sounds on listening difficulty were investigated and compared to the known benefits to word intelligibility scores. Listening tests were used to assess word intelligibility and perceived listening difficulty of speech in simulated sound fields. The experiments were conducted in three types of sound fields with constant levels of ambient noise: only direct sound, direct sound with early reflections, and direct sound with early reflections and reverberation. The results demonstrate that (1) listening difficulty can better discriminate among these conditions than can word recognition scores; (2) added early reflections increase the effective signal-to-noise ratio equivalent to the added energy in the conditions without reverberation; (3) the benefit of early reflections on difficulty scores is greater than expected from the simple increase in early arriving speech energy with reverberation; (4) word intelligibility tests are most appropriate for conditions with signal-to-noise (S/N) ratios less than 0 dBA, and where S/N is between 0 and 15-dBA S/N, listening difficulty is a more appropriate evaluation tool. .
Finneran, James J; Schlundt, Carolyn E; Dear, Randall; Carder, Donald A; Ridgway, Sam H
2002-06-01
A behavioral response paradigm was used to measure masked underwater hearing thresholds in a bottlenose dolphin (Tursiops truncatus) and a white whale (Delphinapterus leucas) before and after exposure to single underwater impulsive sounds produced from a seismic watergun. Pre- and postexposure thresholds were compared to determine if a temporary shift in masked hearing thresholds (MTTS), defined as a 6-dB or larger increase in postexposure thresholds, occurred. Hearing thresholds were measured at 0.4, 4, and 30 kHz. MTTSs of 7 and 6 dB were observed in the white whale at 0.4 and 30 kHz, respectively, approximately 2 min following exposure to single impulses with peak pressures of 160 kPa, peak-to-peak pressures of 226 dB re 1 microPa, and total energy fluxes of 186 dB re 1 microPa2 x s. Thresholds returned to within 2 dB of the preexposure value approximately 4 min after exposure. No MTTS was observed in the dolphin at the highest exposure conditions: 207 kPa peak pressure, 228 dB re 1 microPa peak-to-peak pressure, and 188 dB re 1 microPa2 x s total energy flux.
Krumm, Bianca; Klump, Georg; Köppl, Christine; Langemann, Ulrike
2017-09-27
We measured the auditory sensitivity of the barn owl ( Tyto alba ), using a behavioural Go/NoGo paradigm in two different age groups, one younger than 2 years ( n = 4) and another more than 13 years of age ( n = 3). In addition, we obtained thresholds from one individual aged 23 years, three times during its lifetime. For computing audiograms, we presented test frequencies of between 0.5 and 12 kHz, covering the hearing range of the barn owl. Average thresholds in quiet were below 0 dB sound pressure level (SPL) for frequencies between 1 and 10 kHz. The lowest mean threshold was -12.6 dB SPL at 8 kHz. Thresholds were the highest at 12 kHz, with a mean of 31.7 dB SPL. Test frequency had a significant effect on auditory threshold but age group had no significant effect. There was no significant interaction between age group and test frequency. Repeated threshold estimates over 21 years from a single individual showed only a slight increase in thresholds. We discuss the auditory sensitivity of barn owls with respect to other species and suggest that birds, which generally show a remarkable capacity for regeneration of hair cells in the basilar papilla, are naturally protected from presbycusis. © 2017 The Author(s).
Noise exposure and auditory thresholds of German airline pilots: a cross-sectional study
Müller, Reinhard; Schneider, Joachim
2017-01-01
Objective The cockpit workplace of airline pilots is a noisy environment. This study examines the hearing thresholds of pilots with respect to ambient noise and communication sound. Methods The hearing of 487 German pilots was analysed by audiometry in the frequency range of 125 Hz–16 kHz in varying age groups. Cockpit noise (free-field) data and communication sound (acoustic manikin) measurements were evaluated. Results The ambient noise levels in cockpits were found to be between 74 and 80 dB(A), and the sound pressure levels under the headset were found to be between 84 and 88 dB(A). The left–right threshold differences at 3, 4 and 6 kHz show evidence of impaired hearing at the left ear, which worsens by age. In the age groups <40/≥40 years the mean differences at 3 kHz are 2/3 dB, at 4 kHz 2/4 dB and at 6 kHz 1/6 dB. In the pilot group which used mostly the left ear for communication tasks (43 of 45 are in the older age group) the mean difference at 3 kHz is 6 dB, at 4 kHz 7 dB and at 6 kHz 10 dB. The pilots who used the headset only at the right ear also show worse hearing at the left ear of 2 dB at 3 kHz, 3 dB at 4 kHz and at 6 kHz. The frequency-corrected exposure levels under the headset are 7–11 dB(A) higher than the ambient noise with an averaged signal-to-noise ratio for communication of about 10 dB(A). Conclusions The left ear seems to be more susceptible to hearing loss than the right ear. Active noise reduction systems allow for a reduced sound level for the communication signal below the upper exposure action value of 85 dB(A) and allow for a more relaxed working environment for pilots. PMID:28559452
Promising Electric Aircraft Drive Systems
NASA Technical Reports Server (NTRS)
Dudley, Michael R.
2010-01-01
An overview of electric aircraft propulsion technology performance thresholds for key power system components is presented. A weight comparison of electric drive systems with equivalent total delivered energy is made to help identify component performance requirements, and promising research and development opportunities.
2016-08-10
Anno, et al. 2003). The asymptomatic level (0.75 Gy) is considered the lower dose threshold of the presence of symptoms from acute radiation ...high probability of acute injury due to prompt radiation (shown in yellow, > 0.75-Gy equivalent dose) and low probability of acute injury from prompt...of an urban nuclear-weapon detonation as associated with the possibility of acute , deterministic radiation effects. Equivalent-dose calculations for
Independence of Echo-Threshold and Echo-Delay in the Barn Owl
Nelson, Brian S.; Takahashi, Terry T.
2008-01-01
Despite their prevalence in nature, echoes are not perceived as events separate from the sounds arriving directly from an active source, until the echo's delay is long. We measured the head-saccades of barn owls and the responses of neurons in their auditory space-maps while presenting a long duration noise-burst and a simulated echo. Under this paradigm, there were two possible stimulus segments that could potentially signal the location of the echo. One was at the onset of the echo; the other, after the offset of the direct (leading) sound, when only the echo was present. By lengthening the echo's duration, independently of its delay, spikes and saccades were evoked by the source of the echo even at delays that normally evoked saccades to only the direct source. An echo's location thus appears to be signaled by the neural response evoked after the offset of the direct sound. PMID:18974886
Automated detection of sperm whale sounds as a function of abrupt changes in sound intensity
NASA Astrophysics Data System (ADS)
Walker, Christopher D.; Rayborn, Grayson H.; Brack, Benjamin A.; Kuczaj, Stan A.; Paulos, Robin L.
2003-04-01
An algorithm designed to detect abrupt changes in sound intensity was developed and used to identify and count sperm whale vocalizations and to measure boat noise. The algorithm is a MATLAB routine that counts the number of occurrences for which the change in intensity level exceeds a threshold. The algorithm also permits the setting of a ``dead time'' interval to prevent the counting of multiple pulses within a single sperm whale click. This algorithm was used to analyze digitally sampled recordings of ambient noise obtained from the Gulf of Mexico using near bottom mounted EARS buoys deployed as part of the Littoral Acoustic Demonstration Center experiment. Because the background in these data varied slowly, the result of the application of the algorithm was automated detection of sperm whale clicks and creaks with results that agreed well with those obtained by trained human listeners. [Research supported by ONR.
Efroymson, R A; Suter, G W
2001-04-01
An ecological risk assessment framework for aircraft overflights has been developed, with special emphasis on military applications. This article presents the analysis of effects and risk characterization phases; the problem formulation and exposure analysis phases are presented in a companion article. The framework addresses the effects of sound, visual stressors, and collision on the abundance and production of wildlife populations. Profiles of effects, including thresholds, are highlighted for two groups of endpoint species: ungulates (hoofed mammals) and pinnipeds (seals, sea lions, walruses). Several factors complicate the analysis of effects for aircraft overflights. Studies of the effects of aircraft overflights previously have not been associated with a quantitative assessment framework; therefore no consistent relations between exposure and population-level response have been developed. Information on behavioral effects of overflights by military aircraft (or component stressors) on most wildlife species is sparse. Moreover, models that relate behavioral changes to abundance or reproduction, and those that relate behavioral or hearing effects thresholds from one population to another are generally not available. The aggregation of sound frequencies, durations, and the view of the aircraft into the single exposure metric of slant distance is not always the best predictor of effects, but effects associated with more specific exposure metrics (e.g., narrow sound spectra) may not be easily determined or added. The weight of evidence and uncertainty analyses of the risk characterization for overflights are also discussed in this article.
Two-Plasmon Decay: Simulations and Experiments on the NIKE Laser System
NASA Astrophysics Data System (ADS)
Phillips, Lee; Weaver, J. L.; Oh, J.; Schmitt, A. J.; Obenschain, S.; Colombant, D.
2009-11-01
NIKE is a Krf laser system at the Naval Research Laboratory used to explore hydrodynamic stability, equation of state, and other issues arising in the research toward inertial fusion energy. The relatively small KrF wavelength, according to widely used theories, raises the threshold of most parametric instabilities. We report on simulations performed using the FAST3d radiation hydrocode to design TPD experiments. By post-processing the results of the simulations we have designed experiments that have explored the use of simple threshold formulas (from developing theories) and help establish the soundness of our simulational approach. Turning to the targets proposed for ICF energy research, we have found that among the designs for the proposed Fusion Test Facility (Obenschain et al., Phys. Plasmas 13 056320 (2006)), are some that are below LPI thresholds. We have also studied high-gain KrF shock ignition designs and found that they are below LPI thresholds for most of the implosion, becoming susceptible to TPD only late in the pulse.
The VERITAS Facility: A Virtual Environment Platform for Human Performance Research
2016-01-01
IAE The IAE supports the audio environment that users experience during the course of an experiment. This includes environmental sounds, user-to...future, we are looking towards a database-based system that would use MySQL or an equivalent product to store the large data sets and provide standard
Electroacoustic Performance of Direct-Input Hearing Aids with FM Amplification Systems.
ERIC Educational Resources Information Center
Thibodeau, Linda M.
1990-01-01
The electroacoustic performance of 18 direct-input and two inductive-coupling hearing aids was compared when operating with two different frequency modulation (FM) systems. The most significant differences occurred in full-on gain, equivalent-input noise, and frequency response, as opposed to high frequency average saturation sound pressure level…
Ni Zhisinisszi. Nee Nahnah Aideenau (I Speak Cheyenne. I Speak Arapaho).
ERIC Educational Resources Information Center
Berlin, William
This is a primary-level reader to be used in connection with a bilingual education program. The story is preceded by a pronunciation guide, which lists Cheyenne and Arapaho sound symbols and their approximate English equivalents. Each illustrated page contains a Cheyenne and an Arapaho caption with an English translation. (AM)
Letter Names and Sounds: Their Implications for the Phonetisation Process
ERIC Educational Resources Information Center
Silva, Cristina; Almeida, Tiago; Alves Martins, Margarida
2010-01-01
Our aim was to analyse the impact of the characteristics of words used in spelling programmes and the nature of instructional guidelines on the evolution from grapho-perceptive writing to phonetic writing in preschool children. The participants were 50 5-year-old children, divided in five equivalent groups in intelligence, phonological skills and…
The Scaling of Broadband Shock-Associated Noise with Increasing Temperature
NASA Technical Reports Server (NTRS)
Miller, Steven A. E.
2013-01-01
A physical explanation for the saturation of broadband shock-associated noise (BBSAN) intensity with increasing jet stagnation temperature has eluded investigators. An explanation is proposed for this phenomenon with the use of an acoustic analogy. To isolate the relevant physics, the scaling of BBSAN peak intensity level at the sideline observer location is examined. The equivalent source within the framework of an acoustic analogy for BBSAN is based on local field quantities at shock wave shear layer interactions. The equivalent source combined with accurate calculations of the propagation of sound through the jet shear layer, using an adjoint vector Green's function solver of the linearized Euler equations, allows for predictions that retain the scaling with respect to stagnation pressure and allows for saturation of BBSAN with increasing stagnation temperature. The sources and vector Green's function have arguments involving the steady Reynolds- Averaged Navier-Stokes solution of the jet. It is proposed that saturation of BBSAN with increasing jet temperature occurs due to a balance between the amplication of the sound propagation through the shear layer and the source term scaling.
Hansen, Hans; Weber, Reinhard
2009-02-01
An evaluation of tonal components in noise using a semantic differential approach yields several perceptual and connotative factors. This study investigates the effect of culture on these factors with the aid of equivalent listening tests carried out in Japan (n=20), France (n=23), and Germany (n=20). The data's equivalence level is determined by a bias analysis. This analysis gives insight in the cross-cultural validity of the scales used for sound character determination. Three factors were extracted by factor analysis in all cultural subsamples: pleasant, metallic, and power. By employing appropriate target rotations of the factor spaces, the rotated factors were compared and they yield high similarities between the different cultural subsamples. To check cross-cultural differences in means, an item bias analysis was conducted. The a priori assumption of unbiased scales is rejected; the differences obtained are partially linked to bias effects. Acoustical sound descriptors were additionally tested for the semantic dimensions. The high agreement in judgments between the different cultural subsamples contrast the moderate success of the signal parameters to describe the dimensions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaper, H. G.
1998-01-05
An interdisciplinary project encompassing sound synthesis, music composition, sonification, and visualization of music is facilitated by the high-performance computing capabilities and the virtual-reality environments available at Argonne National Laboratory. The paper describes the main features of the project's centerpiece, DIASS (Digital Instrument for Additive Sound Synthesis); ''A.N.L.-folds'', an equivalence class of compositions produced with DIASS; and application of DIASS in two experiments in the sonification of complex scientific data. Some of the larger issues connected with this project, such as the changing ways in which both scientists and composers perform their tasks, are briefly discussed.
Sensor system for heart sound biomonitor
NASA Astrophysics Data System (ADS)
Maple, Jarrad L.; Hall, Leonard T.; Agzarian, John; Abbott, Derek
1999-09-01
Heart sounds can be utilized more efficiently by medical doctors when they are displayed visually, rather than through a conventional stethoscope. A system whereby a digital stethoscope interfaces directly to a PC will be directly along with signal processing algorithms, adopted. The sensor is based on a noise cancellation microphone, with a 450 Hz bandwidth and is sampled at 2250 samples/sec with 12-bit resolution. Further to this, we discuss for comparison a piezo-based sensor with a 1 kHz bandwidth. A major problem is that the recording of the heart sound into these devices is subject to unwanted background noise which can override the heart sound and results in a poor visual representation. This noise originates from various sources such as skin contact with the stethoscope diaphragm, lung sounds, and other surrounding sounds such as speech. Furthermore we demonstrate a solution using 'wavelet denoising'. The wavelet transform is used because of the similarity between the shape of wavelets and the time-domain shape of a heartbeat sound. Thus coding of the waveform into the wavelet domain is achieved with relatively few wavelet coefficients, in contrast to the many Fourier components that would result from conventional decomposition. We show that the background noise can be dramatically reduced by a thresholding operation in the wavelet domain. The principle is that the background noise codes into many small broadband wavelet coefficients that can be removed without significant degradation of the signal of interest.
Food approach conditioning and discrimination learning using sound cues in benthic sharks.
Vila Pouca, Catarina; Brown, Culum
2018-07-01
The marine environment is filled with biotic and abiotic sounds. Some of these sounds predict important events that influence fitness while others are unimportant. Individuals can learn specific sound cues and 'soundscapes' and use them for vital activities such as foraging, predator avoidance, communication and orientation. Most research with sounds in elasmobranchs has focused on hearing thresholds and attractiveness to sound sources, but very little is known about their abilities to learn about sounds, especially in benthic species. Here we investigated if juvenile Port Jackson sharks could learn to associate a musical stimulus with a food reward, discriminate between two distinct musical stimuli, and whether individual personality traits were linked to cognitive performance. Five out of eight sharks were successfully conditioned to associate a jazz song with a food reward delivered in a specific corner of the tank. We observed repeatable individual differences in activity and boldness in all eight sharks, but these personality traits were not linked to the learning performance assays we examined. These sharks were later trained in a discrimination task, where they had to distinguish between the same jazz and a novel classical music song, and swim to opposite corners of the tank according to the stimulus played. The sharks' performance to the jazz stimulus declined to chance levels in the discrimination task. Interestingly, some sharks developed a strong side bias to the right, which in some cases was not the correct side for the jazz stimulus.
Why is auditory frequency weighting so important in regulation of underwater noise?
Tougaard, Jakob; Dähne, Michael
2017-10-01
A key question related to regulating noise from pile driving, air guns, and sonars is how to take into account the hearing abilities of different animals by means of auditory frequency weighting. Recordings of pile driving sounds, both in the presence and absence of a bubble curtain, were evaluated against recent thresholds for temporary threshold shift (TTS) for harbor porpoises by means of four different weighting functions. The assessed effectivity, expressed as time until TTS, depended strongly on choice of weighting function: 2 orders of magnitude larger for an audiogram-weighted TTS criterion relative to an unweighted criterion, highlighting the importance of selecting the right frequency weighting.
Assessment of Marine Mammal Impact Zones for Use of Military Sonar in the Baltic Sea.
Andersson, Mathias H; Johansson, Torbjörn
2016-01-01
Military sonars are known to have caused cetaceans to strand. Navies in shallow seas use different frequencies and sonar pulses, commonly frequencies between 25 and 100 kHz, compared with most studied NATO sonar systems that have been evaluated for their environmental impact. These frequencies match the frequencies of best hearing in the harbor porpoises and seals resident in the Baltic Sea. This study uses published temporary and permanent threshold shifts, measured behavioral response thresholds, technical specifications of a sonar system, and environmental parameters affecting sound propagation common for the Baltic Sea to estimate the impact zones for harbor porpoises and seals.
Sounds, Behaviour, and Auditory Receptors of the Armoured Ground Cricket, Acanthoplus longipes
Kowalski, Kerstin; Lakes-Harlan, Reinhard
2010-01-01
The auditory sensory system of the taxon Hetrodinae has not been studied previously. Males of the African armoured ground cricket, Acanthoplus longipes (Orthoptera: Tettigoniidae: Hetrodinae) produce a calling song that lasts for minutes and consists of verses with two pulses. About three impulses are in the first pulse and about five impulses are in the second pulse. In contrast, the disturbance stridulation consists of verses with about 14 impulses that are not separated in pulses. Furthermore, the inter-impulse intervals of both types of sounds are different, whereas verses have similar durations. This indicates that the neuronal networks for sound generation are not identical. The frequency spectrum peaks at about 15 kHz in both types of sounds, whereas the hearing threshold has the greatest sensitivity between 4 and 10 kHz. The auditory afferents project into the prothoracic ganglion. The foreleg contains about 27 sensory neurons in the crista acustica; the midleg has 18 sensory neurons, and the hindleg has 14. The auditory system is similar to those of other Tettigoniidae. PMID:20569136
Developing an active artificial hair cell using nonlinear feedback control
NASA Astrophysics Data System (ADS)
Joyce, Bryan S.; Tarazaga, Pablo A.
2015-09-01
The hair cells in the mammalian cochlea convert sound-induced vibrations into electrical signals. These cells have inspired a variety of artificial hair cells (AHCs) to serve as biologically inspired sound, fluid flow, and acceleration sensors and could one day replace damaged hair cells in humans. Most of these AHCs rely on passive transduction of stimulus while it is known that the biological cochlea employs active processes to amplify sound-induced vibrations and improve sound detection. In this work, an active AHC mimics the active, nonlinear behavior of the cochlea. The AHC consists of a piezoelectric bimorph beam subjected to a base excitation. A feedback control law is used to reduce the linear damping of the beam and introduce a cubic damping term which gives the AHC the desired nonlinear behavior. Model and experimental results show the AHC amplifies the response due to small base accelerations, has a higher frequency sensitivity than the passive system, and exhibits a compressive nonlinearity like that of the mammalian cochlea. This bio-inspired accelerometer could lead to new sensors with lower thresholds of detection, improved frequency sensitivities, and wider dynamic ranges.
Long-term high-intensity sound stimulation inhibits h current (Ih ) in CA1 pyramidal neurons.
Cunha, A O S; Ceballos, C C; de Deus, J L; Leão, R M
2018-05-19
Afferent neurotransmission to hippocampal pyramidal cells can lead to long-term changes to their intrinsic membrane properties and affect many ion currents. One of the most plastic neuronal currents is the hyperpolarization activated cationic current (I h ), which changes in CA1 pyramidal cells in response to many types of physiological and pathological processes, including auditory stimulation. Recently we demonstrated that long-term potentiation (LTP) in rat hippocampal Schaffer-CA1 synapses is depressed by high-intensity sound stimulation. Here we investigated if a long-term high-intensity sound stimulation could affect intrinsic membrane properties of rat CA1 pyramidal neurons. Our results showed that I h is depressed by long-term high intensity sound exposure (1 minute of 110 dB sound, applied two times per day for 10 days). This resulted in a decreased resting membrane potential, increased membrane input resistance and time constant, and decreased action potential threshold. In addition, CA1 pyramidal neurons from sound-exposed animals fired more action potentials than neurons from control animals; However, this effect was not caused by a decreased I h . Interestingly, a single episode (1 minute) of 110 dB sound stimulation which also inhibits hippocampal LTP did not affect I h and firing in pyramidal neurons, suggesting that effects on I h are long-term responses to high intensity sound exposure. Our results show that prolonged exposure to high-intensity sound affects intrinsic membrane properties of hippocampal pyramidal neurons, mainly by decreasing the amplitude of I h . This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Influence of sound source location on the behavior and physiology of the precedence effect in cats.
Dent, Micheal L; Tollin, Daniel J; Yin, Tom C T
2009-08-01
Psychophysical experiments on the precedence effect (PE) in cats have shown that they localize pairs of auditory stimuli presented from different locations in space based on the spatial position of the stimuli and the interstimulus delay (ISD) between the stimuli in a manner similar to humans. Cats exhibit localization dominance for pairs of transient stimuli with |ISDs| from approximately 0.4 to 10 ms, summing localization for |ISDs| < 0.4 ms and breakdown of fusion for |ISDs| > 10 ms, which is the approximate echo threshold. The neural correlates to the PE have been described in both anesthetized and unanesthetized animals at many levels from auditory nerve to cortex. Single-unit recordings from the inferior colliculus (IC) and auditory cortex of cats demonstrate that neurons respond to both lead and lag sounds at ISDs above behavioral echo thresholds, but the response to the lag is reduced at shorter ISDs, consistent with localization dominance. Here the influence of the relative locations of the leading and lagging sources on the PE was measured behaviorally in a psychophysical task and physiologically in the IC of awake behaving cats. At all configurations of lead-lag stimulus locations, the cats behaviorally exhibited summing localization, localization dominance, and breakdown of fusion. Recordings from the IC of awake behaving cats show neural responses paralleling behavioral measurements. Both behavioral and physiological results suggest systematically shorter echo thresholds when stimuli are further apart in space.
Influence of Sound Source Location on the Behavior and Physiology of the Precedence Effect in Cats
Dent, Micheal L.; Tollin, Daniel J.; Yin, Tom C. T.
2009-01-01
Psychophysical experiments on the precedence effect (PE) in cats have shown that they localize pairs of auditory stimuli presented from different locations in space based on the spatial position of the stimuli and the interstimulus delay (ISD) between the stimuli in a manner similar to humans. Cats exhibit localization dominance for pairs of transient stimuli with |ISDs| from ∼0.4 to 10 ms, summing localization for |ISDs| < 0.4 ms and breakdown of fusion for |ISDs| > 10 ms, which is the approximate echo threshold. The neural correlates to the PE have been described in both anesthetized and unanesthetized animals at many levels from auditory nerve to cortex. Single-unit recordings from the inferior colliculus (IC) and auditory cortex of cats demonstrate that neurons respond to both lead and lag sounds at ISDs above behavioral echo thresholds, but the response to the lag is reduced at shorter ISDs, consistent with localization dominance. Here the influence of the relative locations of the leading and lagging sources on the PE was measured behaviorally in a psychophysical task and physiologically in the IC of awake behaving cats. At all configurations of lead-lag stimulus locations, the cats behaviorally exhibited summing localization, localization dominance, and breakdown of fusion. Recordings from the IC of awake behaving cats show neural responses paralleling behavioral measurements. Both behavioral and physiological results suggest systematically shorter echo thresholds when stimuli are further apart in space. PMID:19439668
The Gap Detection Test: Can It Be Used to Diagnose Tinnitus?
Boyen, Kris; Başkent, Deniz; van Dijk, Pim
2015-01-01
Animals with induced tinnitus showed difficulties in detecting silent gaps in sounds, suggesting that the tinnitus percept may be filling the gap. The main purpose of this study was to evaluate the applicability of this approach to detect tinnitus in human patients. The authors first hypothesized that gap detection would be impaired in patients with tinnitus, and second, that gap detection would be more impaired at frequencies close to the tinnitus frequency of the patient. Twenty-two adults with bilateral tinnitus, 20 age-matched and hearing loss-matched subjects without tinnitus, and 10 young normal-hearing subjects participated in the study. To determine the characteristics of the tinnitus, subjects matched an external sound to their perceived tinnitus in pitch and loudness. To determine the minimum detectable gap, the gap threshold, an adaptive psychoacoustic test was performed three times by each subject. In this gap detection test, four different stimuli, with various frequencies and bandwidths, were presented at three intensity levels each. Similar to previous reports of gap detection, increasing sensation level yielded shorter gap thresholds for all stimuli in all groups. Interestingly, the tinnitus group did not display elevated gap thresholds in any of the four stimuli. Moreover, visual inspection of the data revealed no relation between gap detection performance and perceived tinnitus pitch. These findings show that tinnitus in humans has no effect on the ability to detect gaps in auditory stimuli. Thus, the testing procedure in its present form is not suitable for clinical detection of tinnitus in humans.
Interpretation of magnetotelluric resistivity and phase soundings over horizontal layers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patella, D.
1976-02-01
The present paper deals with a new inverse method for quantitatively interpreting magnetotelluric apparent resistivity and phase-lag sounding curves over horizontally stratified earth sections. The recurrent character of the general formula relating the wave impedance of an (n-l)-layered medium to that of an n-layered medium suggests the use of the method of reduction to a lower boundary plane, as originally termed by Koefoed in the case of dc resistivity soundings. The layering parameters are so directly derived by a simple iterative procedure. The method is applicable for any number of layers but only when both apparent resistivity and phase-lag soundingmore » curves are jointly available. Moreover no sophisticated algorithm is required: a simple desk electronic calculator together with a sheet of two-layer apparent resistivity and phase-lag master curves are sufficient to reproduce earth sections which, in the range of equivalence, are all consistent with field data.« less
Development and evaluation of a general aviation real world noise simulator
NASA Technical Reports Server (NTRS)
Galanter, E.; Popper, R.
1980-01-01
An acoustic playback system is described which realistically simulates the sounds experienced by the pilot of a general aviation aircraft during engine idle, take-off, climb, cruise, descent, and landing. The physical parameters of the signal as they appear in the simulator environment are compared to analogous parameters derived from signals recorded during actual flight operations. The acoustic parameters of the simulated and real signals during cruise conditions are within plus or minus two dB in third octave bands from 0.04 to 4 kHz. The overall A-weighted levels of the signals are within one dB of signals generated in the actual aircraft during equivalent maneuvers. Psychoacoustic evaluations of the simulator signal are compared with similar measurements based on transcriptions of actual aircraft signals. The subjective judgments made by human observers support the conclusion that the simulated sound closely approximates transcribed sounds of real aircraft.
Reanalysis of the Stratosphere in GEOS-5: Lessons Learned from MERRA and Future Prospects
NASA Technical Reports Server (NTRS)
Pawson, Steven
2011-01-01
The MERRA configuration of GEOS-5 includes about 30 layers in the middle atmosphere, with an upper boundary near 80km. Stratospheric Sounding Unit (SSU) and Advanced microwave sounding unit ( AMSU) radiance data are assimilated, which yield good constraints on the analyses up to the upper stratosphere. This paper examines the performance of MERRA, with foci on: the somewhat erratic system behavior in the 1980s, as numerous SSU instruments were available for short periods; the transition from SSU to AMSU radiances; conflicts between equivalent instruments on different platforms, given in the context of bias correction and the diurnal cycle; and, the relative stability of the analyses in the 21st Century. The results from MERRA provide guidance for how to use the operational polar-orbiting datasets in future reanalyses. Additional discussion will be directed at the possible use of research data sets, from limb-sounding instruments, in future multi-decadal products.
Horizontal sound localization in cochlear implant users with a contralateral hearing aid.
Veugen, Lidwien C E; Hendrikse, Maartje M E; van Wanrooij, Marc M; Agterberg, Martijn J H; Chalupper, Josef; Mens, Lucas H M; Snik, Ad F M; John van Opstal, A
2016-06-01
Interaural differences in sound arrival time (ITD) and in level (ILD) enable us to localize sounds in the horizontal plane, and can support source segregation and speech understanding in noisy environments. It is uncertain whether these cues are also available to hearing-impaired listeners who are bimodally fitted, i.e. with a cochlear implant (CI) and a contralateral hearing aid (HA). Here, we assessed sound localization behavior of fourteen bimodal listeners, all using the same Phonak HA and an Advanced Bionics CI processor, matched with respect to loudness growth. We aimed to determine the availability and contribution of binaural (ILDs, temporal fine structure and envelope ITDs) and monaural (loudness, spectral) cues to horizontal sound localization in bimodal listeners, by systematically varying the frequency band, level and envelope of the stimuli. The sound bandwidth had a strong effect on the localization bias of bimodal listeners, although localization performance was typically poor for all conditions. Responses could be systematically changed by adjusting the frequency range of the stimulus, or by simply switching the HA and CI on and off. Localization responses were largely biased to one side, typically the CI side for broadband and high-pass filtered sounds, and occasionally to the HA side for low-pass filtered sounds. HA-aided thresholds better than 45 dB HL in the frequency range of the stimulus appeared to be a prerequisite, but not a guarantee, for the ability to indicate sound source direction. We argue that bimodal sound localization is likely based on ILD cues, even at frequencies below 1500 Hz for which the natural ILDs are small. These cues are typically perturbed in bimodal listeners, leading to a biased localization percept of sounds. The high accuracy of some listeners could result from a combination of sufficient spectral overlap and loudness balance in bimodal hearing. Copyright © 2016 Elsevier B.V. All rights reserved.
Papes, Sandra; Ladich, Friedrich
2011-01-01
Background Sound production and hearing sensitivity of ectothermic animals are affected by the ambient temperature. This is the first study investigating the influence of temperature on both sound production and on hearing abilities in a fish species, namely the neotropical Striped Raphael catfish Platydoras armatulus. Methodology/Principal Findings Doradid catfishes produce stridulation sounds by rubbing the pectoral spines in the shoulder girdle and drumming sounds by an elastic spring mechanism which vibrates the swimbladder. Eight fish were acclimated for at least three weeks to 22°, then to 30° and again to 22°C. Sounds were recorded in distress situations when fish were hand-held. The stridulation sounds became shorter at the higher temperature, whereas pulse number, maximum pulse period and sound pressure level did not change with temperature. The dominant frequency increased when the temperature was raised to 30°C and the minimum pulse period became longer when the temperature decreased again. The fundamental frequency of drumming sounds increased at the higher temperature. Using the auditory evoked potential (AEP) recording technique, the hearing thresholds were tested at six different frequencies from 0.1 to 4 kHz. The temporal resolution was determined by analyzing the minimum resolvable click period (0.3–5 ms). The hearing sensitivity was higher at the higher temperature and differences were more pronounced at higher frequencies. In general, latencies of AEPs in response to single clicks became shorter at the higher temperature, whereas temporal resolution in response to double-clicks did not change. Conclusions/Significance These data indicate that sound characteristics as well as hearing abilities are affected by temperatures in fishes. Constraints imposed on hearing sensitivity at different temperatures cannot be compensated even by longer acclimation periods. These changes in sound production and detection suggest that acoustic orientation and communication are affected by temperature changes in the neotropical catfish P. armatulus. PMID:22022618
Sulaiman, A H; Seluakumaran, K; Husain, R
2013-08-01
To investigate listening habits and hearing risks associated with the use of personal listening devices among urban high school students in Malaysia. Cross-sectional, descriptive study. In total, 177 personal listening device users (13-16 years old) were interviewed to elicit their listening habits (e.g. listening duration, volume setting) and symptoms of hearing loss. Their listening levels were also determined by asking them to set their usual listening volume on an Apple iPod TM playing a pre-selected song. The iPod's sound output was measured with an artificial ear connected to a sound level meter. Subjects also underwent pure tone audiometry to ascertain their hearing thresholds at standard frequencies (0.5-8 kHz) and extended high frequencies (9-16 kHz). The mean measured listening level and listening duration for all subjects were 72.2 dBA and 1.2 h/day, respectively. Their self-reported listening levels were highly correlated with the measured levels (P < 0.001). Subjects who listened at higher volumes also tend to listen for longer durations (P = 0.012). Male subjects listened at a significantly higher volume than female subjects (P = 0.008). When sound exposure levels were compared with the recommended occupational noise exposure limit, 4.5% of subjects were found to be listening at levels which require mandatory hearing protection in the occupational setting. Hearing loss (≥25 dB hearing level at one or more standard test frequencies) was detected in 7.3% of subjects. Subjects' sound exposure levels from the devices were positively correlated with their hearing thresholds at two of the extended high frequencies (11.2 and 14 kHz), which could indicate an early stage of noise-induced hearing loss. Although the average high school student listened at safe levels, a small percentage of listeners were exposed to harmful sound levels. Preventive measures are needed to avoid permanent hearing damage in high-risk listeners. Copyright © 2013 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Jones, Matthew D.; Taylor, Janet L.; Booth, John; Barry, Benjamin K.
2016-01-01
Exercise-induced hypoalgesia is well described, but the underlying mechanisms are unclear. The aim of this study was to examine the effect of exercise on somatosensory evoked potentials, laser evoked potentials, pressure pain thresholds and heat pain thresholds. These were recorded before and after 3-min of isometric elbow flexion exercise at 40% of the participant's maximal voluntary force, or an equivalent period of rest. Exercise-induced hypoalgesia was confirmed in two experiments (Experiment 1–SEPs; Experiment 2–LEPs) by increased pressure pain thresholds at biceps brachii (24.3 and 20.6% increase in Experiment 1 and 2, respectively; both d > 0.84 and p < 0.001) and first dorsal interosseous (18.8 and 21.5% increase in Experiment 1 and 2, respectively; both d > 0.57 and p < 0.001). In contrast, heat pain thresholds were not significantly different after exercise (forearm: 10.8% increase, d = 0.35, p = 0.10; hand: 3.6% increase, d = 0.06, p = 0.74). Contrasting effects of exercise on the amplitude of laser evoked potentials (14.6% decrease, d = −0.42, p = 0.004) and somatosensory evoked potentials (10.9% increase, d = −0.02, p = 1) were also observed, while an equivalent period of rest showed similar habituation (laser evoked potential: 7.3% decrease, d = −0.25, p = 0.14; somatosensory evoked potential: 20.7% decrease, d = −0.32, p = 0.006). The differential response of pressure pain thresholds and heat pain thresholds to exercise is consistent with relative insensitivity of thermal nociception to the acute hypoalgesic effects of exercise. Conflicting effects of exercise on somatosensory evoked potentials and laser evoked potentials were observed. This may reflect non-nociceptive contributions to the somatosensory evoked potential, but could also indicate that peripheral nociceptors contribute to exercise-induced hypoalgesia. PMID:27965587
Exercise Thresholds on Trial: Are They Really Equivalent?
Caen, Kevin; Vermeire, Kobe; Bourgois, Jan G; Boone, Jan
2018-06-01
The interchangeable use of whole-body exercise thresholds and breakpoints (BP) in the local oxygenation response, as measured via near-infrared spectroscopy, has recently been questioned in scientific literature. Therefore, the present study aimed to longitudinally investigate the interrelationship of four commonly used exercise thresholds: critical power (CP), the respiratory compensation point (RCP), and BP in muscle (m[HHb]BP) and brain (c[O2Hb]BP) oxygenation. Nine male participants (21.8 ± 1.2 yr) completed 6 wk of cycling interval training. Before and after this intervention period, subjects performed a ramp incremental exercise protocol to determine RCP, m[HHb]BP, and c[O2Hb]BP and four constant work rate (WR) tests to calculate CP. WR associated with CP, RCP, m[HHB]BP, and c[O2Hb]BP increased by 7.7% ± 4.2%, 13.6% ± 9.0%, 9.8% ± 5.7%, and 11.3% ± 11.1%, respectively. CP was lower (pre: 260 ± 32 W, post: 280 ± 41 W; P < 0.05) than the WR associated with RCP (pre: 281 ± 28 W, post: 318 ± 36 W) and c[O2Hb]BP (pre: 283 ± 36 W, post: 313 ± 32 W) which occurred concomitantly (P = 0.683). M[HHb]BP occurred at the highest WR and differed from all others (pre: 313 ± 23 W, post: 344 ± 32 W; P < 0.05). Training-induced WR differences (ΔWR) did not contrast between thresholds, and initial parameter differences were not affected by the intervention (P = 0.253). Thresholds were partly correlated before (R = 0.67-0.85, P < 0.05) and after (R = 0.83-0.96, P < 0.05) training, but ΔWR values were not associated (P > 0.05). Results of the present study strongly question true equivalence of CP, RCP, m[HHb]BP, and c[O2Hb]BP during ramp incremental exercise. Therefore, these exercise thresholds should not be used interchangeably.
Zhou, Ji-Xun; Zhang, Xue-Zhen
2012-12-01
Several physics-based seabed geoacoustic models (including the Biot theory) predict that compressional wave attenuation α(2) in sandy marine sediments approximately follows quadratic frequency dependence at low frequencies, i.e., α(2)≈kf(n) (dB/m), n=2. A recent paper on broadband geoacoustic inversions from low frequency (LF) field measurements, made at 20 locations around the world, has indicated that the frequency exponent of the effective sound attenuation n≈1.80 in a frequency band of 50-1000 Hz [Zhou et al., J. Acoust. Soc. Am. 125, 2847-2866 (2009)]. Carey and Pierce hypothesize that the discrepancy is due to the inversion models' neglect of shear wave effects [J. Acoust. Soc. Am. 124, EL271-EL277 (2008)]. The broadband geoacoustic inversions assume that the seabottom is an equivalent fluid and sound waves interact with the bottom at small grazing angles. The shear wave velocity and attenuation in the upper layer of ocean bottoms are estimated from the LF field-inverted effective bottom attenuations using a near-grazing bottom reflection expression for the equivalent fluid model, derived by Zhang and Tindle [J. Acoust. Soc. Am. 98, 3391-3396 (1995)]. The resultant shear wave velocity and attenuation are consistent with the SAX99 measurement at 25 Hz and 1000 Hz. The results are helpful for the analysis of shear wave effects on long-range sound propagation in shallow water.
[Comparative evaluation of mastoidoplasty results in application of various plastic materials].
Zaporoshchenko, A Iu; Kravchenko, S V
2015-01-01
The results of surgical treatment of 62 patients, suffering chronic purulent middle otitis, were analyzed. The structure of mastoid processus and attic constitutes a base for choice of middle ear surgical sanation. Sanation operation with preservation or reconstruction of external acoustical meatus posterior wall was finished with combined mastoidoplasty using autobone, spongioid bone bioimplant Tutoplast or bioceramic material "Sintekost". Achievement of a steady sanating effect have promoted in late postoperative period a trustworthy lowering of the perception threshold of the bone--conducted sounds as on vocal, and also on high frequencies, while of the air--conducted sounds--on vocal frequencies. This permits in perspective to perform a hearing--improving operations with good functional result.
Multi-level basis selection of wavelet packet decomposition tree for heart sound classification.
Safara, Fatemeh; Doraisamy, Shyamala; Azman, Azreen; Jantan, Azrul; Abdullah Ramaiah, Asri Ranga
2013-10-01
Wavelet packet transform decomposes a signal into a set of orthonormal bases (nodes) and provides opportunities to select an appropriate set of these bases for feature extraction. In this paper, multi-level basis selection (MLBS) is proposed to preserve the most informative bases of a wavelet packet decomposition tree through removing less informative bases by applying three exclusion criteria: frequency range, noise frequency, and energy threshold. MLBS achieved an accuracy of 97.56% for classifying normal heart sound, aortic stenosis, mitral regurgitation, and aortic regurgitation. MLBS is a promising basis selection to be suggested for signals with a small range of frequencies. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.
Visualizing the deep end of sound: plotting multi-parameter results from infrasound data analysis
NASA Astrophysics Data System (ADS)
Perttu, A. B.; Taisne, B.
2016-12-01
Infrasound is sound below the threshold of human hearing: approximately 20 Hz. The field of infrasound research, like other waveform based fields relies on several standard processing methods and data visualizations, including waveform plots and spectrograms. The installation of the International Monitoring System (IMS) global network of infrasound arrays, contributed to the resurgence of infrasound research. Array processing is an important method used in infrasound research, however, this method produces data sets with a large number of parameters, and requires innovative plotting techniques. The goal in designing new figures is to be able to present easily comprehendible, and information-rich plots by careful selection of data density and plotting methods.
Musical expertise and foreign speech perception
Martínez-Montes, Eduardo; Hernández-Pérez, Heivet; Chobert, Julie; Morgado-Rodríguez, Lisbet; Suárez-Murias, Carlos; Valdés-Sosa, Pedro A.; Besson, Mireille
2013-01-01
The aim of this experiment was to investigate the influence of musical expertise on the automatic perception of foreign syllables and harmonic sounds. Participants were Cuban students with high level of expertise in music or in visual arts and with the same level of general education and socio-economic background. We used a multi-feature Mismatch Negativity (MMN) design with sequences of either syllables in Mandarin Chinese or harmonic sounds, both comprising deviants in pitch contour, duration and Voice Onset Time (VOT) or equivalent that were either far from (Large deviants) or close to (Small deviants) the standard. For both Mandarin syllables and harmonic sounds, results were clear-cut in showing larger MMNs to pitch contour deviants in musicians than in visual artists. Results were less clear for duration and VOT deviants, possibly because of the specific characteristics of the stimuli. Results are interpreted as reflecting similar processing of pitch contour in speech and non-speech sounds. The implications of these results for understanding the influence of intense musical training from childhood to adulthood and of genetic predispositions for music on foreign language perception are discussed. PMID:24294193
Musical expertise and foreign speech perception.
Martínez-Montes, Eduardo; Hernández-Pérez, Heivet; Chobert, Julie; Morgado-Rodríguez, Lisbet; Suárez-Murias, Carlos; Valdés-Sosa, Pedro A; Besson, Mireille
2013-01-01
The aim of this experiment was to investigate the influence of musical expertise on the automatic perception of foreign syllables and harmonic sounds. Participants were Cuban students with high level of expertise in music or in visual arts and with the same level of general education and socio-economic background. We used a multi-feature Mismatch Negativity (MMN) design with sequences of either syllables in Mandarin Chinese or harmonic sounds, both comprising deviants in pitch contour, duration and Voice Onset Time (VOT) or equivalent that were either far from (Large deviants) or close to (Small deviants) the standard. For both Mandarin syllables and harmonic sounds, results were clear-cut in showing larger MMNs to pitch contour deviants in musicians than in visual artists. Results were less clear for duration and VOT deviants, possibly because of the specific characteristics of the stimuli. Results are interpreted as reflecting similar processing of pitch contour in speech and non-speech sounds. The implications of these results for understanding the influence of intense musical training from childhood to adulthood and of genetic predispositions for music on foreign language perception are discussed.
Jenkins, Herman A; Uhler, Kristin
2012-01-01
To compare the speech understanding abilities of cochlear implant listeners using 2 microphone technologies, the Otologics fully implantable Carina and the Cochlear Freedom microphones. Feasibility study using direct comparison of the 2 microphones, nonrandomized and nonblinded within case studies. Tertiary referral center hospital outpatient clinic. Four subjects with greater than 1 year of unilateral listening experience with the Freedom Cochlear Implant and a CNC word score higher than 40%. A Carina microphone coupled to a percutaneous plug was implanted on the ipsilateral side of the cochlear implant. Two months were allowed for healing before connecting to the Carina microphone. The percutaneous plug was connected to a body worn external processor with output leads inserted into the auxiliary port of the Freedom processor. Subjects were instructed to use each of the 2 microphones for half of their daily implant use. Aided pure tone thresholds, consonant-nucleus-consonant (CNC), Bamford-Kowel-Bench Speech in Noise test (BKN-SIN), and Abbreviated Profile of Hearing Aid Benefit. All subjects had sound perceptions using both microphones. The loudness and quality of the sound was judged to be poorer with the Carina in the first 2 subjects. The latter 2 demonstrated essential equivalence in the second two listeners, with the exception of the Abbreviated Profile of Hearing Aid Benefit reporting greater percentage of problems for the Carina in the background noise situation for subject 0011-003PP. CNC word scores were better with the Freedom than the Carina in all 4 subjects. The latter 2 showed improved speech perception abilities with the Carina, compared with the first 2. The BKB-SIN showed consistently better results with the Freedom in noise. Early observations indicate that it is potentially feasible to use the fully implanted Carina microphone with the Freedom Cochlear Implant. The authors would anticipate that outcomes would improve as more knowledge is gained in signal processing and with the fabrication of an integrated device.
Bizley, Jennifer K; Walker, Kerry M M; King, Andrew J; Schnupp, Jan W H
2013-01-01
Spectral timbre is an acoustic feature that enables human listeners to determine the identity of a spoken vowel. Despite its importance to sound perception, little is known about the neural representation of sound timbre and few psychophysical studies have investigated timbre discrimination in non-human species. In this study, ferrets were positively conditioned to discriminate artificial vowel sounds in a two-alternative-forced-choice paradigm. Animals quickly learned to discriminate the vowel sound /u/ from /ε/ and were immediately able to generalize across a range of voice pitches. They were further tested in a series of experiments designed to assess how well they could discriminate these vowel sounds under different listening conditions. First, a series of morphed vowels was created by systematically shifting the location of the first and second formant frequencies. Second, the ferrets were tested with single formant stimuli designed to assess which spectral cues they could be using to make their decisions. Finally, vowel discrimination thresholds were derived in the presence of noise maskers presented from either the same or a different spatial location. These data indicate that ferrets show robust vowel discrimination behavior across a range of listening conditions and that this ability shares many similarities with human listeners.
Another ``new'' metric for outdoor amphitheater criteria
NASA Astrophysics Data System (ADS)
Berens, Robert S.
2005-09-01
Since the late 1960s, when amplified musical performances began being held there, Atlanta's open-air Chastain Park Amphitheater has been the source of enormous friction between the City, the venue's owner, and the wealthy, politically-connected residential community abutting the Park. To identify the characteristics of concert event sound to which neighbors are particularly sensitive, sound levels were monitored during 17 concerts, ranging from quiet jazz and classical performances to rock-and-roll and hip-hop. Community sound levels were monitored at 25 locations, including nine where measurements were made simultaneously inside and outside homes. The study team confirmed that low-frequency sound was the one feature of concert-related sound that community residents identified as most problematic, but that only a relatively small proportion of the Chastain concerts resulted in any significant community annoyance. After assessing the spectral characteristics of the most troublesome concerts, a new compliance metric has been proposed to address low-frequency annoyance issues: a two-tiered exceedence threshold, based on 1-minute LEQ levels in the 63 Hz octave band measured at the rear of the amphitheater, with a concert-event ``exceedence'' defined to be either a 1-minute LEQ(63 Hz) level greater than 95 dB or more than ten 1-minute LEQ(63 Hz) levels greater than 90 dB.
Bizley, Jennifer K; Walker, Kerry MM; King, Andrew J; Schnupp, Jan WH
2013-01-01
Spectral timbre is an acoustic feature that enables human listeners to determine the identity of a spoken vowel. Despite its importance to sound perception, little is known about the neural representation of sound timbre and few psychophysical studies have investigated timbre discrimination in non-human species. In this study, ferrets were positively conditioned to discriminate artificial vowel sounds in a two-alternative-forced-choice paradigm. Animals quickly learned to discriminate the vowel sound /u/ from /ε/, and were immediately able to generalize across a range of voice pitches. They were further tested in a series of experiments designed to assess how well they could discriminate these vowel sounds under different listening conditions. First, a series of morphed vowels was created by systematically shifting the location of the first and second formant frequencies. Second, the ferrets were tested with single formant stimuli designed to assess which spectral cues they could be using to make their decisions. Finally, vowel discrimination thresholds were derived in the presence of noise maskers presented from either the same or a different spatial location. These data indicate that ferrets show robust vowel discrimination behavior across a range of listening conditions and that this ability shares many similarities with human listeners. PMID:23297909
Boyle, Kelly S; Colleye, Orphal; Parmentier, Eric
2014-09-22
Elucidating the origins of complex biological structures has been one of the major challenges of evolutionary studies. Within vertebrates, the capacity to produce regular coordinated electric organ discharges (EODs) has evolved independently in different fish lineages. Intermediate stages, however, are not known. We show that, within a single catfish genus, some species are able to produce sounds, electric discharges or both signals (though not simultaneously). We highlight that both acoustic and electric communication result from actions of the same muscle. In parallel to their abilities, the studied species show different degrees of myofibril development in the sonic and electric muscle. The lowest myofibril density was observed in Synodontis nigriventris, which produced EODs but no swim bladder sounds, whereas the greatest myofibril density was observed in Synodontis grandiops, the species that produced the longest sound trains but did not emit EODs. Additionally, S. grandiops exhibited the lowest auditory thresholds. Swim bladder sounds were similar among species, while EODs were distinctive at the species level. We hypothesize that communication with conspecifics favoured the development of species-specific EOD signals and suggest an evolutionary explanation for the transition from a fast sonic muscle to electrocytes. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
Ricketts, Todd A; Dittberner, Andrew B; Johnson, Earl E
2008-02-01
One factor that has been shown to greatly affect sound quality is audible bandwidth. Provision of gain for frequencies above 4-6 kHz has not generally been supported for groups of hearing aid wearers. The purpose of this study was to determine if preference for bandwidth extension in hearing aid processed sounds was related to the magnitude of hearing loss in individual listeners. Ten participants with normal hearing and 20 participants with mild-to-moderate hearing loss completed the study. Signals were processed using hearing aid-style compression algorithms and filtered using two cutoff frequencies, 5.5 and 9 kHz, which were selected to represent bandwidths that are achievable in modern hearing aids. Round-robin paired comparisons based on the criteria of preferred sound quality were made for 2 different monaurally presented brief sound segments, including music and a movie. Results revealed that preference for either the wider or narrower bandwidth (9- or 5.5-kHz cutoff frequency, respectively) was correlated with the slope of hearing loss from 4 to 12 kHz, with steep threshold slopes associated with preference for narrower bandwidths. Consistent preference for wider bandwidth is present in some listeners with mild-to-moderate hearing loss.
Evidence of Cnidarians sensitivity to sound after exposure to low frequency noise underwater sources
NASA Astrophysics Data System (ADS)
Solé, Marta; Lenoir, Marc; Fontuño, José Manuel; Durfort, Mercè; van der Schaar, Mike; André, Michel
2016-12-01
Jellyfishes represent a group of species that play an important role in oceans, particularly as a food source for different taxa and as a predator of fish larvae and planktonic prey. The massive introduction of artificial sound sources in the oceans has become a concern to science and society. While we are only beginning to understand that non-hearing specialists like cephalopods can be affected by anthropogenic noises and regulation is underway to measure European water noise levels, we still don’t know yet if the impact of sound may be extended to other lower level taxa of the food web. Here we exposed two species of Mediterranean Scyphozoan medusa, Cotylorhiza tuberculata and Rhizostoma pulmo to a sweep of low frequency sounds. Scanning electron microscopy (SEM) revealed injuries in the statocyst sensory epithelium of both species after exposure to sound, that are consistent with the manifestation of a massive acoustic trauma observed in other species. The presence of acoustic trauma in marine species that are not hearing specialists, like medusa, shows the magnitude of the problem of noise pollution and the complexity of the task to determine threshold values that would help building up regulation to prevent permanent damage of the ecosystems.
Parra, Johanna; de Suremain, Aurelie; Berne Audeoud, Frederique; Ego, Anne; Debillon, Thierry
2017-12-01
This study measured sound levels in a 2008 built French neonatal intensive care unit (NICU) and compared them to the 2007 American Academy of Pediatrics (AAP) recommendations. The ultimate aim was to identify factors that could influence noise levels. The study measured sound in 17 single or double rooms in the NICU. Two dosimeters were installed in each room, one inside and one outside the incubators, and these conducted measurements over a 24-hour period. The noise metrics measured were the equivalent continuous sound level (L eq ), the maximum noise level (L max ) and the noise level exceeded for 10% of the measurement period (L 10 ). The mean L eq , L 10 and L max were 60.4, 62.1 and 89.1 decibels (dBA), which exceeded the recommended levels of 45, 50 and 65 dBA (p < 0.001), respectively. The L eq inside the incubator was significantly higher than in the room (+8 dBA, p < 0.001). None of the newborns' characteristics, the environment or medical care was correlated to an increased noise level, except for a postconceptional age below 32 weeks. The sound levels significantly exceeded the AAP recommendations, particularly inside incubators. A multipronged strategy is required to improve the sound environment and protect the neonates' sensory development. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
46 CFR 161.002-10 - Automatic fire detecting system control unit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... inches) or other audible alarm that has an equivalent sound level and that is mounted at the control unit... section. (4) Non-interference. The control unit shall be so arranged as to permit one or any number of... the visible alarm to remain until the trouble has been corrected. (3) Non-interference. The control...
46 CFR 161.002-10 - Automatic fire detecting system control unit.
Code of Federal Regulations, 2014 CFR
2014-10-01
... inches) or other audible alarm that has an equivalent sound level and that is mounted at the control unit... section. (4) Non-interference. The control unit shall be so arranged as to permit one or any number of... the visible alarm to remain until the trouble has been corrected. (3) Non-interference. The control...
46 CFR 161.002-10 - Automatic fire detecting system control unit.
Code of Federal Regulations, 2013 CFR
2013-10-01
... inches) or other audible alarm that has an equivalent sound level and that is mounted at the control unit... section. (4) Non-interference. The control unit shall be so arranged as to permit one or any number of... the visible alarm to remain until the trouble has been corrected. (3) Non-interference. The control...
46 CFR 161.002-10 - Automatic fire detecting system control unit.
Code of Federal Regulations, 2011 CFR
2011-10-01
... inches) or other audible alarm that has an equivalent sound level and that is mounted at the control unit... section. (4) Non-interference. The control unit shall be so arranged as to permit one or any number of... the visible alarm to remain until the trouble has been corrected. (3) Non-interference. The control...
Helleman, Hiske W; Dreschler, Wouter A
2015-02-01
To investigate the effect of a break in music exposure on temporary threshold shifts. A cross-over design where subjects are exposed to dance music for either two hours consecutively, or exposed to two hours of dance music with a one-hour break in between. Outcome measure was the change in hearing threshold, measured in 1-dB steps at different time points after ending the music. Eighteen normal-hearing subjects participated in this study. Changes in pure-tone threshold were observed in both conditions and were similar, regardless of the break. Threshold shifts could be averaged for 1000, 2000, and 4000 Hz. The shift immediately after the ending of the music was 1.7 dB for right ears, and 3.4 dB for left ears. The difference between left and right ears was significant. One hour after the exposure, right ears were recovered to baseline conditions whereas left ears showed a small but clinically irrelevant remaining shift of approximately 1 dB. The advice to use chill-out zones is still valid, because this helps to reduce the duration to the exposure. This study does not provide evidence that a rest period gives an additional reduction of temporary threshold shifts.
Auditory enhancement of visual perception at threshold depends on visual abilities.
Caclin, Anne; Bouchet, Patrick; Djoulah, Farida; Pirat, Elodie; Pernier, Jacques; Giard, Marie-Hélène
2011-06-17
Whether or not multisensory interactions can improve detection thresholds, and thus widen the range of perceptible events is a long-standing debate. Here we revisit this question, by testing the influence of auditory stimuli on visual detection threshold, in subjects exhibiting a wide range of visual-only performance. Above the perceptual threshold, crossmodal interactions have indeed been reported to depend on the subject's performance when the modalities are presented in isolation. We thus tested normal-seeing subjects and short-sighted subjects wearing their usual glasses. We used a paradigm limiting potential shortcomings of previous studies: we chose a criterion-free threshold measurement procedure and precluded exogenous cueing effects by systematically presenting a visual cue whenever a visual target (a faint Gabor patch) might occur. Using this carefully controlled procedure, we found that concurrent sounds only improved visual detection thresholds in the sub-group of subjects exhibiting the poorest performance in the visual-only conditions. In these subjects, for oblique orientations of the visual stimuli (but not for vertical or horizontal targets), the auditory improvement was still present when visual detection was already helped with flanking visual stimuli generating a collinear facilitation effect. These findings highlight that crossmodal interactions are most efficient to improve perceptual performance when an isolated modality is deficient. Copyright © 2011 Elsevier B.V. All rights reserved.
Photoacoustics of disperse systems: Below cavitation threshold
DOE Office of Scientific and Technical Information (OSTI.GOV)
Egerev, Sergey; Ovchinnikov, Oleg
2012-05-24
The paper considers photoacoustic (PA) conversion while irradiating suspensions in extra-small volume probes with laser pulses having small fluence values. Only linear and nonlinear thermooptical laser sound generation regimes were observed. Thus, good repeatability of acoustic signal parameters informative about probe content was achieved. The experiment conducted has shown how one can avoid the decrease of particles detection sensitivity for the thermooptical mode.
Network Update: Plug-Ins, Forms and All That Java.
ERIC Educational Resources Information Center
Higgins, Chris
1997-01-01
Notes that the desire to make World Wide Web (WWW) pages more interactive and laden with animation, sound, and video brings us to the threshold of the deeper levels of Web page creation. Lists and discusses resources available on the WWW that will aid in learning and using these dynamic functions for Web page development to assist in interactive…
Evaluation of occupational exposure to infrasonic noise in Poland.
Pawlaczyk-Luszczyńska, M
1999-01-01
A short review of infrasound sources and effects on humans is presented. Polish standard PN-86/N-01338 and international standards ISO 7196:1995 and ISO 9612:1997 concerning the measuring techniques of infrasonic noise are described. The results of infrasonic noise measurements performed in the work environment in Poland are discussed. The study concerned the noise emitted by 124 different types of industrial machinery, appliances and means of transport. The measurements were made in typical working conditions with reference to Polish and international standards. The sound pressure levels exceeding Polish admissible values for: (a) workers' health protection were found in 5 (4.0%) cases, (b) ensuring proper conditions for performing basic functions in observational dispatcher cabins etc. in 77 (62.1%) cases; and (c) administration premises, design offices etc. in 92 (74.2%) cases. The admissible sound pressure levels for workers' health protection are in fact the permissible levels for hearing protection, however they do not correspond with the hearing threshold of infrasound the G-weighting characteristic is associated with. The hearing threshold of infrasound (G86 curve) was exceeded in 66.9% of all the industrial machinery and means of transport under study.
Picou, Erin M; Marcrum, Steven C; Ricketts, Todd A
2015-03-01
While potentially improving audibility for listeners with considerable high frequency hearing loss, the effects of implementing nonlinear frequency compression (NFC) for listeners with moderate high frequency hearing loss are unclear. The purpose of this study was to investigate the effects of activating NFC for listeners who are not traditionally considered candidates for this technology. Participants wore study hearing aids with NFC activated for a 3-4 week trial period. After the trial period, they were tested with NFC and with conventional processing on measures of consonant discrimination threshold in quiet, consonant recognition in quiet, sentence recognition in noise, and acceptableness of sound quality of speech and music. Seventeen adult listeners with symmetrical, mild to moderate sensorineural hearing loss participated. Better ear, high frequency pure-tone averages (4, 6, and 8 kHz) were 60 dB HL or better. Activating NFC resulted in lower (better) thresholds for discrimination of /s/, whose spectral center was 9 kHz. There were no other significant effects of NFC compared to conventional processing. These data suggest that the benefits, and detriments, of activating NFC may be limited for this population.
Experimental Analysis of the Mechanism of Hearing under Water
Chordekar, Shai; Kishon-Rabin, Liat; Kriksunov, Leonid; Adelman, Cahtia; Sohmer, Haim
2015-01-01
The mechanism of human hearing under water is debated. Some suggest it is by air conduction (AC), others by bone conduction (BC), and others by a combination of AC and BC. A clinical bone vibrator applied to soft tissue sites on the head, neck, and thorax also elicits hearing by a mechanism called soft tissue conduction (STC) or nonosseous BC. The present study was designed to test whether underwater hearing at low intensities is by AC or by osseous BC based on bone vibrations or by nonosseous BC (STC). Thresholds of normal hearing participants to bone vibrator stimulation with their forehead in air were recorded and again when forehead and bone vibrator were under water. A vibrometer detected vibrations of a dry human skull in all similar conditions (in air and under water) but not when water was the intermediary between the sound source and the skull forehead. Therefore, the intensities required to induce vibrations of the dry skull in water were significantly higher than the underwater hearing thresholds of the participants, under conditions when hearing by AC and osseous BC is not likely. The results support the hypothesis that hearing under water at low sound intensities may be attributed to nonosseous BC (STC). PMID:26770975
Perception of environmental sounds by experienced cochlear implant patients.
Shafiro, Valeriy; Gygi, Brian; Cheng, Min-Yu; Vachhani, Jay; Mulvey, Megan
2011-01-01
Environmental sound perception serves an important ecological function by providing listeners with information about objects and events in their immediate environment. Environmental sounds such as car horns, baby cries, or chirping birds can alert listeners to imminent dangers as well as contribute to one's sense of awareness and well being. Perception of environmental sounds as acoustically and semantically complex stimuli may also involve some factors common to the processing of speech. However, very limited research has investigated the abilities of cochlear implant (CI) patients to identify common environmental sounds, despite patients' general enthusiasm about them. This project (1) investigated the ability of patients with modern-day CIs to perceive environmental sounds, (2) explored associations among speech, environmental sounds, and basic auditory abilities, and (3) examined acoustic factors that might be involved in environmental sound perception. Seventeen experienced postlingually deafened CI patients participated in the study. Environmental sound perception was assessed with a large-item test composed of 40 sound sources, each represented by four different tokens. The relationship between speech and environmental sound perception and the role of working memory and some basic auditory abilities were examined based on patient performance on a battery of speech tests (HINT, CNC, and individual consonant and vowel tests), tests of basic auditory abilities (audiometric thresholds, gap detection, temporal pattern, and temporal order for tones tests), and a backward digit recall test. The results indicated substantially reduced ability to identify common environmental sounds in CI patients (45.3%). Except for vowels, all speech test scores significantly correlated with the environmental sound test scores: r = 0.73 for HINT in quiet, r = 0.69 for HINT in noise, r = 0.70 for CNC, r = 0.64 for consonants, and r = 0.48 for vowels. HINT and CNC scores in quiet moderately correlated with the temporal order for tones. However, the correlation between speech and environmental sounds changed little after partialling out the variance due to other variables. Present findings indicate that environmental sound identification is difficult for CI patients. They further suggest that speech and environmental sounds may overlap considerably in their perceptual processing. Certain spectrotemproral processing abilities are separately associated with speech and environmental sound performance. However, they do not appear to mediate the relationship between speech and environmental sounds in CI patients. Environmental sound rehabilitation may be beneficial to some patients. Environmental sound testing may have potential diagnostic applications, especially with difficult-to-test populations and might also be predictive of speech performance for prelingually deafened patients with cochlear implants.
Underwater temporary threshold shift induced by octave-band noise in three species of pinniped.
Kastak, D; Schusterman, R J; Southall, B L; Reichmuth, C J
1999-08-01
Pure-tone sound detection thresholds were obtained in water for one harbor seal (Phoca vitulina), two California sea lions (Zalophus californianus), and one northern elephant seal (Mirounga angustirostris) before and immediately following exposure to octave-band noise. Additional thresholds were obtained following a 24-h recovery period. Test frequencies ranged from 100 Hz to 2000 Hz and octave-band exposure levels were approximately 60-75 dB SL (sensation level at center frequency). Each subject was trained to dive into a noise field and remain stationed underwater during a noise-exposure period that lasted a total of 20-22 min. Following exposure, three of the subjects showed threshold shifts averaging 4.8 dB (Phoca), 4.9 dB (Zalophus), and 4.6 dB (Mirounga). Recovery to baseline threshold levels was observed in test sessions conducted within 24 h of noise exposure. Control sessions in which the subjects completed a simulated noise exposure produced shifts that were significantly smaller than those observed following noise exposure. These results indicate that noise of moderate intensity and duration is sufficient to induce TTS under water in these pinniped species.
Adaptive spatial filtering improves speech reception in noise while preserving binaural cues.
Bissmeyer, Susan R S; Goldsworthy, Raymond L
2017-09-01
Hearing loss greatly reduces an individual's ability to comprehend speech in the presence of background noise. Over the past decades, numerous signal-processing algorithms have been developed to improve speech reception in these situations for cochlear implant and hearing aid users. One challenge is to reduce background noise while not introducing interaural distortion that would degrade binaural hearing. The present study evaluates a noise reduction algorithm, referred to as binaural Fennec, that was designed to improve speech reception in background noise while preserving binaural cues. Speech reception thresholds were measured for normal-hearing listeners in a simulated environment with target speech generated in front of the listener and background noise originating 90° to the right of the listener. Lateralization thresholds were also measured in the presence of background noise. These measures were conducted in anechoic and reverberant environments. Results indicate that the algorithm improved speech reception thresholds, even in highly reverberant environments. Results indicate that the algorithm also improved lateralization thresholds for the anechoic environment while not affecting lateralization thresholds for the reverberant environments. These results provide clear evidence that this algorithm can improve speech reception in background noise while preserving binaural cues used to lateralize sound.
O'Brien, Anna; Keidser, Gitte; Yeend, Ingrid; Hartley, Lisa; Dillon, Harvey
2010-12-01
Audiometric measurements through a hearing aid ('in-situ') may facilitate provision of hearing services where these are limited. This study investigated the validity and reliability of in-situ air conduction hearing thresholds measured with closed and open domes relative to thresholds measured with insert earphones, and explored sources of variability in the measures. Twenty-four adults with sensorineural hearing impairment attended two sessions in which thresholds and real-ear-to-dial-difference (REDD) values were measured. Without correction, significantly higher low-frequency thresholds in dB HL were measured in-situ than with insert earphones. Differences were due predominantly to differences in ear canal SPL, as measured with the REDD, which were attributed to leaking low-frequency energy. Test-retest data yielded higher variability with the closed dome coupling due to inconsistent seals achieved with this tip. For all three conditions, inter-participant variability in the REDD values was greater than intra-participant variability. Overall, in-situ audiometry is as valid and reliable as conventional audiometry provided appropriate REDD corrections are made and ambient sound in the test environment is controlled.
Soneja, Sutyajeet; Chen, Chen; Tielsch, James M.; Katz, Joanne; Zeger, Scott L.; Checkley, William; Curriero, Frank C.; Breysse, Patrick N.
2014-01-01
Great uncertainty exists around indoor biomass burning exposure-disease relationships due to lack of detailed exposure data in large health outcome studies. Passive nephelometers can be used to estimate high particulate matter (PM) concentrations during cooking in low resource environments. Since passive nephelometers do not have a collection filter they are not subject to sampler overload. Nephelometric concentration readings can be biased due to particle growth in high humid environments and differences in compositional and size dependent aerosol characteristics. This paper explores relative humidity (RH) and gravimetric equivalency adjustment approaches to be used for the pDR-1000 used to assess indoor PM concentrations for a cookstove intervention trial in Nepal. Three approaches to humidity adjustment performed equivalently (similar root mean squared error). For gravimetric conversion, the new linear regression equation with log-transformed variables performed better than the traditional linear equation. In addition, gravimetric conversion equations utilizing a spline or quadratic term were examined. We propose a humidity adjustment equation encompassing the entire RH range instead of adjusting for RH above an arbitrary 60% threshold. Furthermore, we propose new integrated RH and gravimetric conversion methods because they have one response variable (gravimetric PM2.5 concentration), do not contain an RH threshold, and is straightforward. PMID:24950062
Soneja, Sutyajeet; Chen, Chen; Tielsch, James M; Katz, Joanne; Zeger, Scott L; Checkley, William; Curriero, Frank C; Breysse, Patrick N
2014-06-19
Great uncertainty exists around indoor biomass burning exposure-disease relationships due to lack of detailed exposure data in large health outcome studies. Passive nephelometers can be used to estimate high particulate matter (PM) concentrations during cooking in low resource environments. Since passive nephelometers do not have a collection filter they are not subject to sampler overload. Nephelometric concentration readings can be biased due to particle growth in high humid environments and differences in compositional and size dependent aerosol characteristics. This paper explores relative humidity (RH) and gravimetric equivalency adjustment approaches to be used for the pDR-1000 used to assess indoor PM concentrations for a cookstove intervention trial in Nepal. Three approaches to humidity adjustment performed equivalently (similar root mean squared error). For gravimetric conversion, the new linear regression equation with log-transformed variables performed better than the traditional linear equation. In addition, gravimetric conversion equations utilizing a spline or quadratic term were examined. We propose a humidity adjustment equation encompassing the entire RH range instead of adjusting for RH above an arbitrary 60% threshold. Furthermore, we propose new integrated RH and gravimetric conversion methods because they have one response variable (gravimetric PM2.5 concentration), do not contain an RH threshold, and is straightforward.
Bueno, Regiane Cristina Oliveira de Freitas; Bueno, Adeney de Freitas; Moscardi, Flávio; Parra, José Roberto Postali; Hoffmann-Campo, Clara Beatriz
2011-02-01
Defoliation by Anticarsia gemmatalis (Hübner), Pseudoplusia includens (Walker), Spodoptera eridania (Cramer), S. cosmioides (Walker) and S. frugiperda (JE Smith) (Lepidoptera: Noctuidae) was evaluated in four soybean genotypes. A multiple-species economic threshold (ET), based upon the species' feeding capacity, is proposed with the aim of improving growers' management decisions on when to initiate control measures for the species complex. Consumption by A. gemmatalis, S. cosmioides or S. eridania on different genotypes was similar. The highest consumption of P. includens was 92.7 cm(2) on Codetec 219RR; that of S. frugiperda was 118 cm(2) on Codetec 219RR and 115.1 cm(2) on MSoy 8787RR. The insect injury equivalent for S. cosmoides, calculated on the basis of insect consumption, was double the standard consumption by A. gemmatalis, and statistically different from the other species tested, which were similar to each other. As S. cosmioides always defoliated nearly twice the leaf area of the other species, the injury equivalent would be 2 for this lepidopteran species and 1 for the other species. The recommended multiple-species ET to trigger the beginning of insect control would then be 20 insect equivalents per linear metre. Copyright © 2010 Society of Chemical Industry.
Low-Frequency Cortical Oscillations Entrain to Subthreshold Rhythmic Auditory Stimuli
Schroeder, Charles E.; Poeppel, David; van Atteveldt, Nienke
2017-01-01
Many environmental stimuli contain temporal regularities, a feature that can help predict forthcoming input. Phase locking (entrainment) of ongoing low-frequency neuronal oscillations to rhythmic stimuli is proposed as a potential mechanism for enhancing neuronal responses and perceptual sensitivity, by aligning high-excitability phases to events within a stimulus stream. Previous experiments show that rhythmic structure has a behavioral benefit even when the rhythm itself is below perceptual detection thresholds (ten Oever et al., 2014). It is not known whether this “inaudible” rhythmic sound stream also induces entrainment. Here we tested this hypothesis using magnetoencephalography and electrocorticography in humans to record changes in neuronal activity as subthreshold rhythmic stimuli gradually became audible. We found that significant phase locking to the rhythmic sounds preceded participants' detection of them. Moreover, no significant auditory-evoked responses accompanied this prethreshold entrainment. These auditory-evoked responses, distinguished by robust, broad-band increases in intertrial coherence, only appeared after sounds were reported as audible. Taken together with the reduced perceptual thresholds observed for rhythmic sequences, these findings support the proposition that entrainment of low-frequency oscillations serves a mechanistic role in enhancing perceptual sensitivity for temporally predictive sounds. This framework has broad implications for understanding the neural mechanisms involved in generating temporal predictions and their relevance for perception, attention, and awareness. SIGNIFICANCE STATEMENT The environment is full of rhythmically structured signals that the nervous system can exploit for information processing. Thus, it is important to understand how the brain processes such temporally structured, regular features of external stimuli. Here we report the alignment of slowly fluctuating oscillatory brain activity to external rhythmic structure before its behavioral detection. These results indicate that phase alignment is a general mechanism of the brain to process rhythmic structure and can occur without the perceptual detection of this temporal structure. PMID:28411273
MPN estimation of qPCR target sequence recoveries from whole cell calibrator samples
DNA extracts from enumerated target organism cells (calibrator samples) have been used for estimating Enterococcus cell equivalent densities in surface waters by a comparative cycle threshold (Ct) qPCR analysis method. To compare surface water Enterococcus density estimates from ...
500 E Illinois St, June 2013, Lindsay Light Radiological Survey
In the immediatevicinity of the area of the potential contamination the surface gamma readings were 8,400 to 9,500 cpm.The unshielded Ludlum threshold value equivalent to the USEPA cleanup value of 7.1 pCi/g total radiumwas 17,920 cpm.
A large surface photomultiplier based on SiPMs
NASA Astrophysics Data System (ADS)
Barbarino, Giancarlo; de Asmundis, Riccardo; De Rosa, Gianfranca; Vivolo, Daniele; Mollo, Carlos Maximiliano
2013-10-01
Light detection through photosensitive devices represents one of the key issues for a large variety of experiments. In the recent years, Silicon PhotoMultipliers (SiPMs) based on limited Geiger-mode avalanche have been extensively studied in view of their future applications. However, their use is strongly limited by their small sensitive surfaces and by the fact that any increment in the surface turns out into an increase of the dark count rate. In the present work we describe the dark count rate reduction obtained by using a FPGA-based logical circuit for fast pre-processing of pulses from a 3×3 matrix of SiPMs. The prototype we developed supports two SiPMs: we show that a rate reduction from 6.6 Mcps (Mega counts per second) down to 0.436 Mcps at the lowest threshold (0.5 photon-equivalent) and from 1.2 kcps down to 0.02 cps for the highest threshold (3.5 photon-equivalent) is obtainable.
Burkart, Katrin; Schneider, Alexandra; Breitner, Susanne; Khan, Mobarak Hossain; Krämer, Alexander; Endlicher, Wilfried
2011-01-01
This study assessed the effect of temperature and thermal atmospheric conditions on all-cause and cardiovascular mortality in Bangladesh. In particular, differences in the response to elevated temperatures between urban and rural areas were investigated. Generalized additive models (GAMs) for daily death counts, adjusted for trend, season, day of the month and age were separately fitted for urban and rural areas. Breakpoint models were applied for determining the increase in mortality above and below a threshold (equivalent) temperature. Generally, a 'V'-shaped (equivalent) temperature-mortality curve with increasing mortality at low and high temperatures was observed. Particularly, urban areas suffered from heat-related mortality with a steep increase above a specific threshold. This adverse heat effect may well increase with ongoing urbanization and the intensification of the urban heat island due to the densification of building structures. Moreover, rising temperatures due to climate change could aggravate thermal stress. Copyright © 2011 Elsevier Ltd. All rights reserved.
Mind the Gap: Two Dissociable Mechanisms of Temporal Processing in the Auditory System
Anderson, Lucy A.
2016-01-01
High temporal acuity of auditory processing underlies perception of speech and other rapidly varying sounds. A common measure of auditory temporal acuity in humans is the threshold for detection of brief gaps in noise. Gap-detection deficits, observed in developmental disorders, are considered evidence for “sluggish” auditory processing. Here we show, in a mouse model of gap-detection deficits, that auditory brain sensitivity to brief gaps in noise can be impaired even without a general loss of central auditory temporal acuity. Extracellular recordings in three different subdivisions of the auditory thalamus in anesthetized mice revealed a stimulus-specific, subdivision-specific deficit in thalamic sensitivity to brief gaps in noise in experimental animals relative to controls. Neural responses to brief gaps in noise were reduced, but responses to other rapidly changing stimuli unaffected, in lemniscal and nonlemniscal (but not polysensory) subdivisions of the medial geniculate body. Through experiments and modeling, we demonstrate that the observed deficits in thalamic sensitivity to brief gaps in noise arise from reduced neural population activity following noise offsets, but not onsets. These results reveal dissociable sound-onset-sensitive and sound-offset-sensitive channels underlying auditory temporal processing, and suggest that gap-detection deficits can arise from specific impairment of the sound-offset-sensitive channel. SIGNIFICANCE STATEMENT The experimental and modeling results reported here suggest a new hypothesis regarding the mechanisms of temporal processing in the auditory system. Using a mouse model of auditory temporal processing deficits, we demonstrate the existence of specific abnormalities in auditory thalamic activity following sound offsets, but not sound onsets. These results reveal dissociable sound-onset-sensitive and sound-offset-sensitive mechanisms underlying auditory processing of temporally varying sounds. Furthermore, the findings suggest that auditory temporal processing deficits, such as impairments in gap-in-noise detection, could arise from reduced brain sensitivity to sound offsets alone. PMID:26865621
Spectral Characteristics of Wake Vortex Sound During Roll-Up
NASA Technical Reports Server (NTRS)
Booth, Earl R., Jr. (Technical Monitor); Zhang, Yan; Wang, Frank Y.; Hardin, Jay C.
2003-01-01
This report presents an analysis of the sound spectra generated by a trailing aircraft vortex during its rolling-up process. The study demonstrates that a rolling-up vortex could produce low frequency (less than 100 Hz) sound with very high intensity (60 dB above threshold of human hearing) at a distance of 200 ft from the vortex core. The spectrum then drops o rapidly thereafter. A rigorous analytical approach has been adopted in this report to derive the spectrum of vortex sound. First, the sound pressure was solved from an alternative treatment of the Lighthill s acoustic analogy approach [1]. After the application of Green s function for free space, a tensor analysis was applied to permit the removal of the source term singularity of the wave equation in the far field. Consequently, the sound pressure is expressed in terms of the retarded time that indicates the time history and spacial distribution of the sound source. The Fourier transformation is then applied to the sound pressure to compute its spectrum. As a result, the Fourier transformation greatly simplifies the expression of the vortex sound pressure involving the retarded time, so that the numerical computation is applicable with ease for axisymmetric line vortices during the rolling-up process. The vortex model assumes that the vortex circulation is proportional to the time and the core radius is a constant. In addition, the velocity profile is assumed to be self-similar along the aircraft flight path, so that a benchmark vortex velocity profile can be devised to obtain a closed form solution, which is then used to validate the numerical calculations for other more realistic vortex profiles for which no closed form solutions are available. The study suggests that acoustic sensors operating at low frequency band could be profitably deployed for detecting the vortex sound during the rolling-up process.
NASA Astrophysics Data System (ADS)
Zhang, Bo; Zhang, Weiyong; Zhu, Jian
2012-04-01
The transfer matrix method, based on plane wave theory, of multi-layer equivalent fluid is employed to evaluate the sound absorbing properties of two-layer-assembled and three-layer-assembled sintered fibrous sheets (generally regarded as a kind of compound absorber or structures). Two objective functions which are more suitable for the optimization of sound absorption properties of multi-layer absorbers within the wider frequency ranges are developed and the optimized results of using two objective functions are also compared with each other. It is found that using the two objective functions, especially the second one, may be more helpful to exert the sound absorbing properties of absorbers at lower frequencies to the best of their abilities. Then the calculation and optimization of sound absorption properties of multi-layer-assembled structures are performed by developing a simulated annealing genetic arithmetic program and using above-mentioned objective functions. Finally, based on the optimization in this work the thoughts of the gradient design over the acoustic parameters- the porosity, the tortuosity, the viscous and thermal characteristic lengths and the thickness of each samples- of porous metals are put forth and thereby some useful design criteria upon the acoustic parameters of each layer of porous fibrous metals are given while applying the multi-layer-assembled compound absorbers in noise control engineering.
Characterizing noise and perceived work environment in a neurological intensive care unit.
Ryherd, Erica E; Waye, Kerstin Persson; Ljungkvist, Linda
2008-02-01
The hospital sound environment is complex. Alarms, medical equipment, activities, and ventilation generate noise that may present occupational problems as well as hinder recovery among patients. In this study, sound measurements and occupant evaluations were conducted in a neurological intensive care unit. Staff completed questionnaires regarding psychological and physiological reactions to the sound environment. A-weighted equivalent, minimum, and maximum (L(Aeq),L(AFMin),L(AFMax)) and C-weighted peak (L(CPeak)) sound pressure levels were measured over five days at patient and staff locations. Acoustical descriptors that may be explored further were investigated, including level distributions, restorative periods, and spectral content. Measurements near the patients showed average L(Aeq) values of 53-58 dB. The mean length of restorative periods (L(Aeq) below 50 dB for more than 5 min) was 9 and 13 min for day and night, respectively. Ninety percent of the time, the L(AFMax) levels exceeded 50 dB and L(CPeak) exceeded 70 dB. Dosimeters worn by the staff revealed higher noise levels. Personnel perceived the noise as contributing to stress symptoms. Compared to the majority of previous studies, this study provides a more thorough description of intensive care noise and aids in understanding how the sound environment may be disruptive to occupants.
Andrés, Pilar; Parmentier, Fabrice B R; Escera, Carles
2006-01-01
The aim of this study was to examine the effects of aging on the involuntary capture of attention by irrelevant sounds (distraction) and the use of these sounds as warning cues (alertness) in an oddball paradigm. We compared the performance of older and younger participants on a well-characterized auditory-visual distraction task. Based on the dissociations observed in aging between attentional processes sustained by the anterior and posterior attentional networks, our prediction was that distraction by irrelevant novel sounds would be stronger in older adults than in young adults while both groups would be equally able to use sound as an alert to prepare for upcoming stimuli. The results confirmed both predictions: there was a larger distraction effect in the older participants, but the alert effect was equivalent in both groups. These results give support to the frontal hypothesis of aging [Raz, N. (2000). Aging of the brain and its impact on cognitive performance: integration of structural and functional finding. In F.I.M. Craik & T.A. Salthouse (Eds.) Handbook of aging and cognition (pp. 1-90). Mahwah, NJ: Erlbaum; West, R. (1996). An application of prefrontal cortex function theory to cognitive aging. Psychological Bulletin, 120, 272-292].
Quieting Weinberg 5C: a case study in hospital noise control.
MacLeod, Mark; Dunn, Jeffrey; Busch-Vishniac, Ilene J; West, James E; Reedy, Anita
2007-06-01
Weinberg 5C of Johns Hopkins Hospital is a very noisy hematological cancer unit in a relatively new building of a large medical campus. Because of the requirements for dealing with immuno-suppressed patients, options for introducing sound absorbing materials are limited. In this article, a case study of noise control in a hospital, the sound environment in the unit before treatment is described, the chosen noise control approach of adding custom-made sound absorbing panels is presented, and the impact of the noise control installation is discussed. The treatment of Weinberg 5C involved creating sound absorbing panels of 2-in.-thick fiberglass wrapped in an anti-bacterial fabric. Wallpaper paste was used to hold the fabric to the backing of the fiberglass. Installation of these panels on the ceiling and high on corridor walls had a dramatic effect. The noise on the unit (as measured by the equivalent sound pressure level) was immediately reduced by 5 dB(A) and the reverberation time dropped by a factor of over 2. Further, this drop in background noise and reverberation time understates the dramatic impact of the change. Surveys of staff and patients before and after the treatment indicated a change from viewing the unit as very noisy to a view of the unit as relatively quiet.
Feasibility of using fMRI to study mothers responding to infant cries.
Lorberbaum, J P; Newman, J D; Dubno, J R; Horwitz, A R; Nahas, Z; Teneback, C C; Bloomer, C W; Bohning, D E; Vincent, D; Johnson, M R; Emmanuel, N; Brawman-Mintzer, O; Book, S W; Lydiard, R B; Ballenger, J C; George, M S
1999-01-01
While parenting is a universal human behavior, its neuroanatomic basis is currently unknown. Animal data suggest that the cingulate may play an important function in mammalian parenting behavior. For example, in rodents cingulate lesions impair maternal behavior. Here, in an attempt to understand the brain basis of human maternal behavior, we had mothers listen to recorded infant cries and white noise control sounds while they underwent functional MRI (fMRI) of the brain. We hypothesized that mothers would show significantly greater cingulate activity during the cries compared to the control sounds. Of 7 subjects scanned, 4 had fMRI data suitable for analysis. When fMRI data were averaged for these 4 subjects, the anterior cingulate and right medial prefrontal cortex were the only brain regions showing statistically increased activity with the cries compared to white noise control sounds (cluster analysis with one-tailed z-map threshold of P < 0.001 and spatial extent threshold of P < 0.05). These results demonstrate the feasibility of using fMRI to study brain activity in mothers listening to infant cries and that the anterior cingulate may be involved in mothers listening to crying babies. We are currently replicating this study in a larger group of mothers. Future work in this area may help (1) unravel the functional neuroanatomy of the parent-infant bond and (2) examine whether markers of this bond, such as maternal brain response to infant crying, can predict maternal style (i.e., child neglect), offspring temperament, or offspring depression or anxiety.
Re-Sonification of Objects, Events, and Environments
NASA Astrophysics Data System (ADS)
Fink, Alex M.
Digital sound synthesis allows the creation of a great variety of sounds. Focusing on interesting or ecologically valid sounds for music, simulation, aesthetics, or other purposes limits the otherwise vast digital audio palette. Tools for creating such sounds vary from arbitrary methods of altering recordings to precise simulations of vibrating objects. In this work, methods of sound synthesis by re-sonification are considered. Re-sonification, herein, refers to the general process of analyzing, possibly transforming, and resynthesizing or reusing recorded sounds in meaningful ways, to convey information. Applied to soundscapes, re-sonification is presented as a means of conveying activity within an environment. Applied to the sounds of objects, this work examines modeling the perception of objects as well as their physical properties and the ability to simulate interactive events with such objects. To create soundscapes to re-sonify geographic environments, a method of automated soundscape design is presented. Using recorded sounds that are classified based on acoustic, social, semantic, and geographic information, this method produces stochastically generated soundscapes to re-sonify selected geographic areas. Drawing on prior knowledge, local sounds and those deemed similar comprise a locale's soundscape. In the context of re-sonifying events, this work examines processes for modeling and estimating the excitations of sounding objects. These include plucking, striking, rubbing, and any interaction that imparts energy into a system, affecting the resultant sound. A method of estimating a linear system's input, constrained to a signal-subspace, is presented and applied toward improving the estimation of percussive excitations for re-sonification. To work toward robust recording-based modeling and re-sonification of objects, new implementations of banded waveguide (BWG) models are proposed for object modeling and sound synthesis. Previous implementations of BWGs use arbitrary model parameters and may produce a range of simulations that do not match digital waveguide or modal models of the same design. Subject to linear excitations, some models proposed here behave identically to other equivalently designed physical models. Under nonlinear interactions, such as bowing, many of the proposed implementations exhibit improvements in the attack characteristics of synthesized sounds.
NASA Technical Reports Server (NTRS)
Kacprowski, J.; Motylewski, J.; Miazga, J.
1974-01-01
An objective method and apparatus for noise control and acoustic diagnostics of motorcar engines are reported. The method and apparatus let us know whether the noisiness of the vehicle under test exceeds the admissible threshold levels given by appropriate standards and if so what is the main source of the excessive noise. The method consists in measuring both the overall noise level and the sound pressure levels in definite frequency bands while the engine speed is controlled as well and may be fixed at prescribed values. Whenever the individually adjusted threshold level has been exceeded in any frequency band, a self-sustaining control signal is sent.
Hearing in Cichlid Fishes under Noise Conditions
Ladich, Friedrich; Schulz-Mirbach, Tanja
2013-01-01
Background Hearing thresholds of fishes are typically acquired under laboratory conditions. This does not reflect the situation in natural habitats, where ambient noise may mask their hearing sensitivities. In the current study we investigate hearing in terms of sound pressure (SPL) and particle acceleration levels (PAL) of two cichlid species within the naturally occurring range of noise levels. This enabled us to determine whether species with and without hearing specializations are differently affected by noise. Methodology/Principal Findings We investigated auditory sensitivities in the orange chromide Etroplus maculatus, which possesses anterior swim bladder extensions, and the slender lionhead cichlid Steatocranus tinanti, in which the swim bladder is much smaller and lacks extensions. E. maculatus was tested between 0.2 and 3kHz and S. tinanti between 0.1 and 0.5 kHz using the auditory evoked potential (AEP) recording technique. In both species, SPL and PAL audiograms were determined in the presence of quiet laboratory conditions (baseline) and continuous white noise of 110 and 130 dB RMS. Baseline thresholds showed greatest hearing sensitivity around 0.5 kHz (SPL) and 0.2 kHz (PAL) in E. maculatus and 0.2 kHz in S. tinanti. White noise of 110 dB elevated the thresholds by 0–11 dB (SPL) and 7–11 dB (PAL) in E. maculatus and by 1–2 dB (SPL) and by 1–4 dB (PAL) in S. tinanti. White noise of 130 dB elevated hearing thresholds by 13–29 dB (SPL) and 26–32 dB (PAL) in E. maculatus and 6–16 dB (SPL) and 6–19 dB (PAL) in S. tinanti. Conclusions Our data showed for the first time for SPL and PAL thresholds that the specialized species was masked by different noise regimes at almost all frequencies, whereas the non-specialized species was much less affected. This indicates that noise can limit sound detection and acoustic orientation differently within a single fish family. PMID:23469032
Psychophysical investigation of an auditory spatial illusion in cats: the precedence effect.
Tollin, Daniel J; Yin, Tom C T
2003-10-01
The precedence effect (PE) describes several spatial perceptual phenomena that occur when similar sounds are presented from two different locations and separated by a delay. The mechanisms that produce the effect are thought to be responsible for the ability to localize sounds in reverberant environments. Although the physiological bases for the PE have been studied, little is known about how these sounds are localized by species other than humans. Here we used the search coil technique to measure the eye positions of cats trained to saccade to the apparent locations of sounds. To study the PE, brief broadband stimuli were presented from two locations, with a delay between their onsets; the delayed sound meant to simulate a single reflection. Although the cats accurately localized single sources, the apparent locations of the paired sources depended on the delay. First, the cats exhibited summing localization, the perception of a "phantom" sound located between the sources, for delays < +/-400 micros for sources positioned in azimuth along the horizontal plane, but not for sources positioned in elevation along the sagittal plane. Second, consistent with localization dominance, for delays from 400 micros to about 10 ms, the cats oriented toward the leading source location only, with little influence of the lagging source, both for horizontally and vertically placed sources. Finally, the echo threshold was reached for delays >10 ms, where the cats first began to orient to the lagging source on some trials. These data reveal that cats experience the PE phenomena similarly to humans.
Grimm, Giso; Hohmann, Volker; Laugesen, Søren; Neher, Tobias
2017-01-01
In contrast to static sounds, spatially dynamic sounds have received little attention in psychoacoustic research so far. This holds true especially for acoustically complex (reverberant, multisource) conditions and impaired hearing. The current study therefore investigated the influence of reverberation and the number of concurrent sound sources on source movement detection in young normal-hearing (YNH) and elderly hearing-impaired (EHI) listeners. A listening environment based on natural environmental sounds was simulated using virtual acoustics and rendered over headphones. Both near-far (‘radial’) and left-right (‘angular’) movements of a frontal target source were considered. The acoustic complexity was varied by adding static lateral distractor sound sources as well as reverberation. Acoustic analyses confirmed the expected changes in stimulus features that are thought to underlie radial and angular source movements under anechoic conditions and suggested a special role of monaural spectral changes under reverberant conditions. Analyses of the detection thresholds showed that, with the exception of the single-source scenarios, the EHI group was less sensitive to source movements than the YNH group, despite adequate stimulus audibility. Adding static sound sources clearly impaired the detectability of angular source movements for the EHI (but not the YNH) group. Reverberation, on the other hand, clearly impaired radial source movement detection for the EHI (but not the YNH) listeners. These results illustrate the feasibility of studying factors related to auditory movement perception with the help of the developed test setup. PMID:28675088
Lundbeck, Micha; Grimm, Giso; Hohmann, Volker; Laugesen, Søren; Neher, Tobias
2017-01-01
In contrast to static sounds, spatially dynamic sounds have received little attention in psychoacoustic research so far. This holds true especially for acoustically complex (reverberant, multisource) conditions and impaired hearing. The current study therefore investigated the influence of reverberation and the number of concurrent sound sources on source movement detection in young normal-hearing (YNH) and elderly hearing-impaired (EHI) listeners. A listening environment based on natural environmental sounds was simulated using virtual acoustics and rendered over headphones. Both near-far ('radial') and left-right ('angular') movements of a frontal target source were considered. The acoustic complexity was varied by adding static lateral distractor sound sources as well as reverberation. Acoustic analyses confirmed the expected changes in stimulus features that are thought to underlie radial and angular source movements under anechoic conditions and suggested a special role of monaural spectral changes under reverberant conditions. Analyses of the detection thresholds showed that, with the exception of the single-source scenarios, the EHI group was less sensitive to source movements than the YNH group, despite adequate stimulus audibility. Adding static sound sources clearly impaired the detectability of angular source movements for the EHI (but not the YNH) group. Reverberation, on the other hand, clearly impaired radial source movement detection for the EHI (but not the YNH) listeners. These results illustrate the feasibility of studying factors related to auditory movement perception with the help of the developed test setup.
Cross-sensory correspondences and symbolism in spoken and written language.
Walker, Peter
2016-09-01
Lexical sound symbolism in language appears to exploit the feature associations embedded in cross-sensory correspondences. For example, words incorporating relatively high acoustic frequencies (i.e., front/close rather than back/open vowels) are deemed more appropriate as names for concepts associated with brightness, lightness in weight, sharpness, smallness, speed, and thinness, because higher pitched sounds appear to have these cross-sensory features. Correspondences also support prosodic sound symbolism. For example, speakers might raise the fundamental frequency of their voice to emphasize the smallness of the concept they are naming. The conceptual nature of correspondences and their functional bidirectionality indicate they should also support other types of symbolism, including a visual equivalent of prosodic sound symbolism. For example, the correspondence between auditory pitch and visual thinness predicts that a typeface with relatively thin letter strokes will reinforce a word's reference to a relatively high pitch sound (e.g., squeal). An initial rating study confirms that the thinness-thickness of a typeface's letter strokes accesses the same cross-sensory correspondences observed elsewhere. A series of speeded word classification experiments then confirms that the thinness-thickness of letter strokes can facilitate a reader's comprehension of the pitch of a sound named by a word (thinner letter strokes being appropriate for higher pitch sounds), as can the brightness of the text (e.g., white-on-gray text being appropriate for the names of higher pitch sounds). It is proposed that the elementary visual features of text are represented in the same conceptual system as word meaning, allowing cross-sensory correspondences to support visual symbolism in language. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
The Hilbert-Huang Transform-Based Denoising Method for the TEM Response of a PRBS Source Signal
NASA Astrophysics Data System (ADS)
Hai, Li; Guo-qiang, Xue; Pan, Zhao; Hua-sen, Zhong; Khan, Muhammad Younis
2016-08-01
The denoising process is critical in processing transient electromagnetic (TEM) sounding data. For the full waveform pseudo-random binary sequences (PRBS) response, an inadequate noise estimation may result in an erroneous interpretation. We consider the Hilbert-Huang transform (HHT) and its application to suppress the noise in the PRBS response. The focus is on the thresholding scheme to suppress the noise and the analysis of the signal based on its Hilbert time-frequency representation. The method first decomposes the signal into the intrinsic mode function, and then, inspired by the thresholding scheme in wavelet analysis; an adaptive and interval thresholding is conducted to set to zero all the components in intrinsic mode function which are lower than a threshold related to the noise level. The algorithm is based on the characteristic of the PRBS response. The HHT-based denoising scheme is tested on the synthetic and field data with the different noise levels. The result shows that the proposed method has a good capability in denoising and detail preservation.
NASA Technical Reports Server (NTRS)
Hirsch, David; Williams, Jim; Beeson, Harold
2006-01-01
Spacecraft materials selection is based on an upward flammability test conducted in a quiescent environment in the highest-expected oxygen-concentration environment. However, NASA s advanced space exploration program is anticipating using various habitable environments. Because limited data is available to support current program requirements, a different test logic is suggested to address these expanded atmospheric environments through the determination of materials self-extinguishment limits. This paper provides additional pressure effects data on oxygen concentration and partial pressure self-extinguishment limits under quiescent conditions. For the range of total pressures tested, the oxygen concentration and oxygen partial pressure flammability thresholds show a near linear function of total pressure. The oxygen concentration/oxygen partial pressure flammability thresholds depend on the total pressure and appear to increase with increasing oxygen concentration (and oxygen partial pressure). For the Constellation Program, the flammability threshold information will allow NASA to identify materials with increased flammability risk because of oxygen concentration and total pressure changes, minimize potential impacts, and allow for development of sound requirements for new spacecraft and extraterrestrial landers and habitats.
Kastelein, R A; Verboom, W C; Muijsers, M; Jennings, N V; van der Heul, S
2005-05-01
To prevent grounding of ships and collisions between ships in shallow coastal waters, an underwater data collection and communication network is currently under development: Acoustic Communication network for Monitoring of underwater Environment in coastal areas (ACME). Marine mammals might be affected by ACME sounds since they use sounds of similar frequencies (around 12 kHz) for communication, orientation, and prey location. If marine mammals tend to avoid the vicinity of the transmitters, they may be kept away from ecologically important areas by ACME sounds. One marine mammal species that may be affected in the North Sea is the harbour porpoise. Therefore, as part of an environmental impact assessment program, two captive harbour porpoises were subjected to four sounds, three of which may be used in the underwater acoustic data communication network. The effect of each sound was judged by comparing the animals' positions and respiration rates during a test period with those during a baseline period. Each of the four sounds could be made a deterrent by increasing the amplitude of the sound. The porpoises reacted by swimming away from the sounds and by slightly, but significantly, increasing their respiration rate. From the sound pressure level distribution in the pen, and the distribution of the animals during test sessions, discomfort sound level thresholds were determined for each sound. In combination with information on sound propagation in the areas where the communication system may be deployed, the extent of the 'discomfort zone' can be estimated for several source levels (SLs). The discomfort zone is defined as the area around a sound source that harbour porpoises are expected to avoid. Based on these results, SLs can be selected that have an acceptable effect on harbour porpoises in particular areas. The discomfort zone of a communication sound depends on the selected sound, the selected SL, and the propagation characteristics of the area in which the sound system is operational. In shallow, winding coastal water courses, with sandbanks, etc., the type of habitat in which the ACME sounds will be produced, propagation loss cannot be accurately estimated by using a simple propagation model, but should be measured on site. The SL of the communication system should be adapted to each area (taking into account bounding conditions created by narrow channels, sound propagation variability due to environmental factors, and the importance of an area to the affected species). The discomfort zone should not prevent harbour porpoises from spending sufficient time in ecologically important areas (for instance feeding areas), or routes towards these areas.
32 CFR 199.14 - Provider reimbursement methods.
Code of Federal Regulations, 2014 CFR
2014-07-01
... for neonatal services which has standardized costs that exceed a threshold of the greater of two times... CHAMPUS discharges in fiscal year 1988. (iv) Hold harmless provision. At such time as the weights... direct medical education costs. (x) Total full-time equivalents for: (A) Residents. (B) Interns. (xi...
32 CFR 199.14 - Provider reimbursement methods.
Code of Federal Regulations, 2013 CFR
2013-07-01
... for neonatal services which has standardized costs that exceed a threshold of the greater of two times... CHAMPUS discharges in fiscal year 1988. (iv) Hold harmless provision. At such time as the weights... direct medical education costs. (x) Total full-time equivalents for: (A) Residents. (B) Interns. (xi...
A Multilingual Dictionary Also Containing Qazaq Terminology in Phonetics and Phonology
ERIC Educational Resources Information Center
Yurtbasi, Metin
2017-01-01
The aim of this article is to present to the reader a sampling (860 items) from the Qazaq phonological terminology with their equivalents in Russian, English and Turkish. There has been many linguistic studies and publications in the Qazaq sound system both by Qazaq and foreign scholars in form of books, articles and glossaries. Qazaq is a member…
Navy Training Lands Sustainability: Initiation Decision Report
2004-06-01
Health Promotion and Preventative Medicine CLF Combat Logistics Force CMAQ Community Multiscale Air Quality CNEL Community Noise Equivalent Level...Environmental Consequences of Underwater Sound EDQW (DoD) Environmental Data Quality Workgroup EEZ Exclusive Economic Zone EFHA Essential Fish Habitat...Conservation Management Act established a 200-mile fishery conservation zone, which is now known as the Exclusive Economic Zone (EEZ), and established
14 CFR Appendix A to Part 36 - Aircraft Noise Measurement and Evaluation Under § 36.101
Code of Federal Regulations, 2014 CFR
2014-01-01
... involve only minor changes to the airplane type design. The resulting changes in noise can often be... equivalent weighted sound attenuations in each one-third octave band; or (2) The peak noy values at the time... airplane at the time of PNLTM, for each measurement; (e) Average wind velocity 33 ft (10 m) above ground...
ERIC Educational Resources Information Center
Kardos, Leah
2012-01-01
I am a composer, producer, pianist and part-time music lecturer at a Further Education college where I teach composing on Music Technology courses at levels 3 (equivalent to A-level) and 4 (Undergraduate/Foundation Degree). A "Music Technology" course, distinct from a "Music" course, often attracts applicants from diverse musical backgrounds; it…
Detection of cough signals in continuous audio recordings using hidden Markov models.
Matos, Sergio; Birring, Surinder S; Pavord, Ian D; Evans, David H
2006-06-01
Cough is a common symptom of many respiratory diseases. The evaluation of its intensity and frequency of occurrence could provide valuable clinical information in the assessment of patients with chronic cough. In this paper we propose the use of hidden Markov models (HMMs) to automatically detect cough sounds from continuous ambulatory recordings. The recording system consists of a digital sound recorder and a microphone attached to the patient's chest. The recognition algorithm follows a keyword-spotting approach, with cough sounds representing the keywords. It was trained on 821 min selected from 10 ambulatory recordings, including 2473 manually labeled cough events, and tested on a database of nine recordings from separate patients with a total recording time of 3060 min and comprising 2155 cough events. The average detection rate was 82% at a false alarm rate of seven events/h, when considering only events above an energy threshold relative to each recording's average energy. These results suggest that HMMs can be applied to the detection of cough sounds from ambulatory patients. A postprocessing stage to perform a more detailed analysis on the detected events is under development, and could allow the rejection of some of the incorrectly detected events.
Hearing in alpacas (Vicugna pacos): audiogram, localization acuity, and use of binaural locus cues.
Heffner, Rickye S; Koay, Gimseong; Heffner, Henry E
2014-02-01
Behavioral audiograms and sound localization abilities were determined for three alpacas (Vicugna pacos). Their hearing at a level of 60 dB sound pressure level (SPL) (re 20 μPa) extended from 40 Hz to 32.8 kHz, a range of 9.7 octaves. They were most sensitive at 8 kHz, with an average threshold of -0.5 dB SPL. The minimum audible angle around the midline for 100-ms broadband noise was 23°, indicating relatively poor localization acuity and potentially supporting the finding that animals with broad areas of best vision have poorer sound localization acuity. The alpacas were able to localize low-frequency pure tones, indicating that they can use the binaural phase cue, but they were unable to localize pure tones above the frequency of phase ambiguity, thus indicating complete inability to use the binaural intensity-difference cue. In contrast, the alpacas relied on their high-frequency hearing for pinna cues; they could discriminate front-back sound sources using 3-kHz high-pass noise, but not 3-kHz low-pass noise. These results are compared to those of other hoofed mammals and to mammals more generally.
Evaluation Experiment of Ultrasound Computed Tomography for the Abdominal Sound Speed Imaging
NASA Astrophysics Data System (ADS)
Nogami, Keisuke; Yamada, Akira
2007-07-01
Abdominal sound speed tomographic imaging using through-transmission travel time data on the body surface was investigated. To this end, a hundred kHz range low-frequency wave was used to reduce the wave attenuation within an inner body medium. A method was investigated for the reconstruction of the image with the smallest possible number of path data around the abdominal surface. Specifically, the data from a strong scattering spinal cord should be avoided. To fulfill the requirement, the smoothed path algebraic reconstruction technique was introduced. The validity of this method was examined both on the numerically synthesized data and the experimentally measured data for the phantom specimen and actual human subject. It was shown that an abdominal tomographic sound speed image could be successfully obtained by preparing only 32 transducer locations at the circumference around the abdominal surface and their combination of less than 100 number of observation path data as well as by avoiding the data intersecting the spinal cord. In addition, fat regions were extracted having a sound speed lower than the threshold value to demonstrate the possibility of this method for metabolic syndrome diagnosis.
Assessment of directionality performances: comparison between Freedom and CP810 sound processors.
Razza, Sergio; Albanese, Greta; Ermoli, Lucilla; Zaccone, Monica; Cristofari, Eliana
2013-10-01
To compare speech recognition in noise for the Nucleus Freedom and CP810 sound processors using different directional settings among those available in the SmartSound portfolio. Single-subject, repeated measures study. Tertiary care referral center. Thirty-one monoaurally and binaurally implanted subjects (24 children and 7 adults) were enrolled. They were all experienced Nucleus Freedom sound processor users and achieved a 100% open set word recognition score in quiet listening conditions. Each patient was fitted with the Freedom and the CP810 processor. The program setting incorporated Adaptive Dynamic Range Optimization (ADRO) and adopted the directional algorithm BEAM (both devices) and ZOOM (only on CP810). Speech reception threshold (SRT) was assessed in a free-field layout, with disyllabic word list and interfering multilevel babble noise in the 3 different pre-processing configurations. On average, CP810 improved significantly patients' SRTs as compared to Freedom SP after 1 hour of use. Instead, no significant difference was observed in patients' SRT between the BEAM and the ZOOM algorithm fitted in the CP810 processor. The results suggest that hardware developments achieved in the design of CP810 allow an immediate and relevant directional advantage as compared to the previous-generation Freedom device.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borisova, Elena; Lilly, Simon J.; Cantalupo, Sebastiano
A toy model is developed to understand how the spatial distribution of fluorescent emitters in the vicinity of bright quasars could be affected by the geometry of the quasar bi-conical radiation field and by its lifetime. The model is then applied to the distribution of high-equivalent-width Ly α emitters (with rest-frame equivalent widths above 100 Å, threshold used in, e.g., Trainor and Steidel) identified in a deep narrow-band 36 × 36 arcmin{sup 2} image centered on the luminous quasar Q0420–388. These emitters are found near the edge of the field and show some evidence of an azimuthal asymmetry on themore » sky of the type expected if the quasar is radiating in a bipolar cone. If these sources are being fluorescently illuminated by the quasar, the two most distant objects require a lifetime of at least 15 Myr for an opening angle of 60° or more, increasing to more than 40 Myr if the opening angle is reduced to a minimum of 30°. However, some other expected signatures of boosted fluorescence are not seen at the current survey limits, e.g., a fall off in Ly α brightness, or equivalent width, with distance. Furthermore, to have most of the Ly α emission of the two distant sources to be fluorescently boosted would require the quasar to have been significantly brighter in the past. This suggests that these particular sources may not be fluorescent, invalidating the above lifetime constraints. This would cast doubt on the use of this relatively low equivalent width threshold and thus also on the lifetime analysis in Trainor and Steidel.« less
The Gap Detection Test: Can It Be Used to Diagnose Tinnitus?
Boyen, Kris; Başkent, Deniz
2015-01-01
Objectives: Animals with induced tinnitus showed difficulties in detecting silent gaps in sounds, suggesting that the tinnitus percept may be filling the gap. The main purpose of this study was to evaluate the applicability of this approach to detect tinnitus in human patients. The authors first hypothesized that gap detection would be impaired in patients with tinnitus, and second, that gap detection would be more impaired at frequencies close to the tinnitus frequency of the patient. Design: Twenty-two adults with bilateral tinnitus, 20 age-matched and hearing loss–matched subjects without tinnitus, and 10 young normal-hearing subjects participated in the study. To determine the characteristics of the tinnitus, subjects matched an external sound to their perceived tinnitus in pitch and loudness. To determine the minimum detectable gap, the gap threshold, an adaptive psychoacoustic test was performed three times by each subject. In this gap detection test, four different stimuli, with various frequencies and bandwidths, were presented at three intensity levels each. Results: Similar to previous reports of gap detection, increasing sensation level yielded shorter gap thresholds for all stimuli in all groups. Interestingly, the tinnitus group did not display elevated gap thresholds in any of the four stimuli. Moreover, visual inspection of the data revealed no relation between gap detection performance and perceived tinnitus pitch. Conclusions: These findings show that tinnitus in humans has no effect on the ability to detect gaps in auditory stimuli. Thus, the testing procedure in its present form is not suitable for clinical detection of tinnitus in humans. PMID:25822647
Le Prell, Colleen G; Spankovich, Christopher; Lobariñas, Edward; Griffiths, Scott K
2013-09-01
Human hearing is sensitive to sounds from as low as 20 Hz to as high as 20,000 Hz in normal ears. However, clinical tests of human hearing rarely include extended high-frequency (EHF) threshold assessments, at frequencies extending beyond 8000 Hz. EHF thresholds have been suggested for use monitoring the earliest effects of noise on the inner ear, although the clinical usefulness of EHF threshold testing is not well established for this purpose. The primary objective of this study was to determine if EHF thresholds in healthy, young adult college students vary as a function of recreational noise exposure. A retrospective analysis of a laboratory database was conducted; all participants with both EHF threshold testing and noise history data were included. The potential for "preclinical" EHF deficits was assessed based on the measured thresholds, with the noise surveys used to estimate recreational noise exposure. EHF thresholds measured during participation in other ongoing studies were available from 87 participants (34 male and 53 female); all participants had hearing within normal clinical limits (≤25 HL) at conventional frequencies (0.25-8 kHz). EHF thresholds closely matched standard reference thresholds [ANSI S3.6 (1996) Annex C]. There were statistically reliable threshold differences in participants who used music players, with 3-6 dB worse thresholds at the highest test frequencies (10-16 kHz) in participants who reported long-term use of music player devices (>5 yr), or higher listening levels during music player use. It should be possible to detect small changes in high-frequency hearing for patients or participants who undergo repeated testing at periodic intervals. However, the increased population-level variability in thresholds at the highest frequencies will make it difficult to identify the presence of small but potentially important deficits in otherwise normal-hearing individuals who do not have previously established baseline data. American Academy of Audiology.