ANATOMIC VARIATIONS OF HEPATIC ARTERY: A STUDY IN 479 LIVER TRANSPLANTATIONS.
Fonseca-Neto, Olival Cirilo Lucena da; Lima, Heloise Caroline de Souza; Rabelo, Priscylla; Melo, Paulo Sérgio Vieira de; Amorim, Américo Gusmão; Lacerda, Cláudio Moura
2017-01-01
The incidence of anatomic variations of hepatic artery ranges from 20-50% in different series. Variations are especially important in the context of liver orthotopic transplantation, since, besides being an ideal opportunity for surgical anatomical study, their precise identification is crucial to the success of the procedure. To identify the anatomical variations in the hepatic arterial system in hepatic transplantation. 479 medical records of transplanted adult patients in the 13-year period were retrospectively analyzed, and collected data on hepatic arterial anatomy of the deceased donor. It was identified normal hepatic arterial anatomy in 416 donors (86.84%). The other 63 patients (13.15%) showed some variation. According to the Michels classification, the most frequently observed abnormalities were: right hepatic artery branch of superior mesenteric artery (Type III, n=27, 5.63%); left hepatic artery branch of the left gastric artery (Type II, n=13, 2.71%); right hepatic artery arising from the superior mesenteric artery associated with the left hepatic artery arising from the left gastric artery (Type IV, n=4, 0.83%). Similarly, in relation to Hiatt classification, the most prevalent changes were: right hepatic accessory artery or substitute of the superior mesenteric artery (Type III, n=28, 6.05%)), followed by liver ancillary left artery or replacement of gastric artery left (Type II, n=16, 3.34. Fourteen donors (2.92%) showed no anatomical abnormalities defined in classifications, the highest frequency being hepatomesenteric trunk identified in five (01.04%). Detailed knowledge of the variations of hepatic arterial anatomy is of utmost importance to surgeons who perform approaches in this area, particularly in liver transplantation, since their identification and proper management are critical to the success of the procedure. A incidência das variações anatômicas da artéria hepática varia de 20-50% em diferentes casuísticas. Elas são especialmente importantes no contexto do transplante ortotópico hepático, visto que, além de representar oportunidade ideal para seu estudo anatômico cirúrgico, a sua precisa identificação é determinante para o sucesso do procedimento. Identificar as variações anatômicas no sistema arterial hepático em transplantes hepáticos. Foram analisados retrospectivamente, no período de 13 anos, 479 prontuários de pacientes adultos transplantados, sendo coletados dados referentes à anatomia arterial hepática do doador falecido. Identificou-se anatomia arterial hepática normal em 416 doadores (86,84%). Os outros 63 indivíduos (13,15%) apresentaram alguma variação. De acordo com a classificação de Michels, as anomalias mais frequentes foram: artéria hepática direita ramo da artéria mesentérica superior (Tipo III, n=27, 5,63%); artéria hepática esquerda ramo da artéria gástrica esquerda (Tipo II, n=13, 2,71%); artéria hepática direita ramo da artéria mesentérica superior associada à artéria hepática esquerda ramo da artéria gástrica esquerda (Tipo IV, n=4, 0,83%). Do mesmo modo, em relação à Classificação de Hiatt, as variações mais prevalentes foram: artéria hepática direita acessória ou substituta da artéria mesentérica superior (Tipo III, n=28, 6,05%), seguida da artéria hepática esquerda acessória ou substituta da artéria gástrica esquerda (Tipo II, n=16, 3,34%). Quatorze pessoas (2,92%) apresentaram alterações anatômicas sem classificação definida, sendo a de maior frequência o tronco hepatomesentérico, identificado em cinco (1,04%). O conhecimento detalhado das variações da anatomia arterial hepática é de grande importância aos cirurgiões que realizam abordagens nessa região, em especial no transplante hepático, visto que sua identificação e correto manejo são fundamentais para o êxito do procedimento.
Abreu, José Sebastião de; Rocha, Eduardo Arrais; Machado, Isadora Sucupira; Parahyba, Isabelle O; Rocha, Thais Brito; Paes, Fernando José Villar Nogueira; Diogenes, Tereza Cristina Pinheiro; Abreu, Marília Esther Benevides de; Farias, Ana Gardenia Liberato Ponte; Carneiro, Marcia Maria; Paes, José Nogueira
2017-05-01
Normal coronary flow velocity reserve (CFVR) (≥ 2) obtained in the left anterior descending coronary artery (LAD) from transthoracic echocardiography is associated with a good prognosis, but there is no study correlating CFVR with submaximal target heart rate (HR). To evaluate the prognostic value of CFVR obtained in the LAD of patients with preserved (>50%) left ventricular ejection fraction (LVEF) who completed a dobutamine stress echocardiography (DSE), considering target HR. Prospective study of patients with preserved LVEF and CFVR obtained in the LAD who completed DSE. In Group I (GI = 31), normal CFVR was obtained before achieving target HR, and, in Group II (GII = 28), after that. Group III (G III=24) reached target HR, but CFVR was abnormal. Death, acute coronary insufficiency, coronary intervention, coronary angiography without further intervention, and hospitalization were considered events. In 28 ± 4 months, there were 18 (21.6%) events: 6% (2/31) in GI, 18% (5/28) in GII, and 46% (11/24) in GIII. There were 4 (4.8%) deaths, 6 (7.2%) coronary interventions and 8 (9.6%) coronary angiographies without further intervention. In event-free survival by regression analysis, GIII had more events than GI (p < 0.001) and GII (p < 0.045), with no difference between GI and GII (p = 0.160). After adjustment, the only difference was between GIII and GI (p = 0.012). In patients with preserved LVEF and who completed their DSE, normal CFVR obtained before achieving target HR was associated with better prognosis. A reserva de velocidade de fluxo coronariano (RVFC) adequada (≥ 2) obtida na artéria descendente anterior (ADA) através do ecocardiograma transtorácico associa-se a bom prognóstico, mas não há estudo correlacionando-a com a frequência cardíaca (FC) alvo (submáxima). Avaliar o valor prognóstico da RVFC obtida na ADA de pacientes com fração de ejeção do ventrículo esquerdo (FEVE) preservada (>50%) e ecocardiograma sob estresse com dobutamina (EED) concluído, considerando a FC alvo submáxima. studo prospectivo de pacientes com FEVE preservada e RVFC obtida na ADA durante EED concluído. No Grupo I (GI=31), a RVFC adequada foi obtida antes de se atingir a FC alvo, e no Grupo II (G II=28), após. O Grupo III (G III=24) atingiu a FC alvo, mas a RVFC foi inadequada. Foram considerados eventos: óbito, insuficiência coronariana aguda, intervenção coronariana, coronariografia sem intervenção subsequente e internamento hospitalar. Em 28 ± 4 meses, ocorreram 18 (21,6%) eventos, sendo 6% (2/31) no GI, 18% (5/28) no GII e 46% (11/24) no GIII. Foram 4 (4,8%) óbitos, 6 (7,2%) intervenções coronarianas e 8 (9,6%) coronariografias sem intervenção subsequente. Na sobrevida livre de eventos pela análise de regressão, GIII apresentou mais eventos do que GI (p < 0,001) ou GII (p < 0,045), não havendo diferença entre GI e GII (p = 0,160). Após o ajustamento, foi mantida a diferença apenas entre GIII e GI (p = 0,012). Em pacientes com FEVE preservada e EED concluído, a RVFC adequada obtida antes da FC alvo associou-se ao melhor prognóstico.
The brain of the horse: weight and cephalization quotients.
Cozzi, Bruno; Povinelli, Michele; Ballarin, Cristina; Granato, Alberto
2014-01-01
The horse is a common domestic animal whose anatomy has been studied since the XVI century. However, a modern neuroanatomy of this species does not exist and most of the data utilized in textbooks and reviews derive from single specimens or relatively old literature. Here, we report information on the brain of Equus caballus obtained by sampling 131 horses, including brain weight (as a whole and subdivided into its constituents), encephalization quotient (EQ), and cerebellar quotient (CQ), and comparisons with what is known about other relevant species. The mean weight of the fresh brains in our experimental series was 598.63 g (SEM ± 7.65), with a mean body weight of 514.12 kg (SEM ± 15.42). The EQ was 0.78 and the CQ was 0.841. The data we obtained indicate that the horse possesses a large, convoluted brain, with a weight similar to that of other hoofed species of like mass. However, the shape of the brain, the noteworthy folding of the neocortex, and the peculiar longitudinal distribution of the gyri suggest an evolutionary specificity at least partially separate from that of the Cetartiodactyla (even-toed mammals and cetaceans) with whom Perissodactyla (odd-toed mammals) are often grouped.
Soeiro, Alexandre de Matos; Silva, Pedro Gabriel Melo de Barros E; Roque, Eduardo Alberto de Castro; Bossa, Aline Siqueira; César, Maria Cristina; Simões, Sheila Aparecida; Okada, Mariana Yumi; Leal, Tatiana de Carvalho Andreucci Torres; Pedroti, Fátima Cristina Monteiro; Oliveira, Múcio Tavares de
2016-09-01
Recent studies have shown fondaparinux's superiority over enoxaparin in patients with non-ST elevation acute coronary syndrome (ACS), especially in relation to bleeding reduction. The description of this finding in a Brazilian registry has not yet been documented. To compare fondaparinux versus enoxaparin in in-hospital prognosis of non-ST elevation ACS. Multicenter retrospective observational study. A total of 2,282 patients were included (335 in the fondaparinux group, and 1,947 in the enoxaparin group) between May 2010 and May 2015. Demographic, medication intake and chosen coronary treatment data were obtained. Primary outcome was mortality from all causes. Secondary outcome was combined events (cardiogenic shock, reinfarction, death, stroke and bleeding). Comparison between the groups were done through Chi-Square test and T test. Multivariate analysis was done through logistic regression, with significance values defined as p < 0.05. With regards to treatment, we observed the performance of a percutaneous coronary intervention in 40.2% in the fondaparinux group, and in 35.1% in the enoxaparin group (p = 0.13). In the multivariate analysis, we observed significant differences between fondaparinux and enoxaparin groups in relation to combined events (13.8% vs. 22%. OR = 2.93, p = 0.007) and bleeding (2.3% vs. 5.2%, OR = 4.55, p = 0.037), respectively. Similarly to recently published data in international literature, fondaparinux proved superior to enoxaparin for the Brazilian population, with significant reduction of combined events and bleeding. Estudos recentes têm apresentado superioridade do fondaparinux em relação à enoxaparina em pacientes com síndrome coronariana aguda (SCA) sem supradesnivelamento de ST, principalmente relacionada à redução de sangramentos. A descrição desse achado em registro brasileiro ainda não foi documentada. Comparar fondaparinux versus enoxaparina no prognóstico intrahospitalar em SCA sem supradesnivelamento de ST. Estudo retrospectivo, multicêntrico e observacional. Foram incluídos 2.282 pacientes (335 no grupo fondaparinux e 1.947 no grupo enoxaparina) entre maio de 2.010 e maio de 2.015. Foram obtidos dados demográficos, medicações utilizadas e tratamento coronariano adotado. O desfecho primário foi mortalidade por todas as causas. O desfecho secundário foi eventos combinados (choque cardiogênico, reinfarto, morte, acidente vascular cerebral e sangramentos). A comparação entre os grupos foi realizada por meio de Q-quadrado e teste-T. A análise multivariada foi realizada por regressão logística, sendo considerado significativo p < 0,05. Em relação ao tratamento, observou-se realização de intervenção coronária percutânea em 40,2% no grupo fondaparinux e 35,1% no grupo enoxaparina (p = 0,13). Na análise multivariada, observaram-se diferenças significativas entre os grupos fondaparinux e enoxaparina em relação a eventos combinados (13,8% vs. 22%, OR = 2,93, p = 0,007) e sangramentos (2,3% vs. 5,2%, OR = 4,55, p = 0,037), respectivamente. Semelhante aos dados recentemente publicados na literatura mundial, fondaparinux mostrou-se superior à enoxaparina para a população brasileira, com redução significativa de eventos combinados e sangramentos.
Eventos Planetarios Periodicos
NASA Astrophysics Data System (ADS)
Flores Gutierrez, J. D.
1987-05-01
El análisis de las coordenadas ecuatoriales para los planetas Mercurio, Venus, Marte, Júpiter, Saturno, en los instantes en que ocurren algunos eventos astronómicos, como conjunciones, oposiciones,etc., muestra un comportamiento periódico, característico a cada planeta. El caso de Venus es el mejor estudiado. El cálculo de las efemérides a lo largo de 1000 años , indica un período característico de aproximadamente 260 años. Resultados preliminares con otros planetas muestran períodos distintos.
Uso de curativo a vácuo como terapia adjuvante na cicatrização de sítio cirúrgico infectado
de Camargo, Paula Angeleli Bueno; Bertanha, Matheus; Moura, Regina; Jaldin, Rodrigo Gibin; Yoshida, Ricardo de Alvarenga; Pimenta, Rafael Elias Farres; Mariúba, Jamil Victor de Oliveira; Sobreira, Marcone Lima
2016-01-01
Resumo Infecções de sítios cirúrgicos com envolvimento de próteses sintéticas constituem grande desafio para tratamento. Apresentamos o caso de uma paciente com múltiplas comorbidades, histórico de enxerto aortobifemoral há 6 anos e reabordagem das anastomoses femorais por reestenoses há 5 anos. Apresentou dor inguinal esquerda e abaulamento súbitos com diagnóstico de pseudoaneurisma femoral roto e instabilidade hemodinâmica. Foi submetida a correção emergencial com interposição de prótese de dácron recoberta por prata e correção de grande hérnia incisional abdominal com tela sintética ao mesmo tempo. No pós-operatório, manteve-se por longo período sob terapia intensiva com dificuldade de extubação. Nesse ínterim, apresentou deiscência das suturas e fístula purulenta inguinal esquerda em contato com a prótese vascular. Optou-se pelo tratamento conservador, com desbridamento das feridas e aplicação de curativo a vácuo. A paciente evoluiu com melhora e cicatrização das feridas. Essa pode se constituir em ferramenta importante em casos similares.
López Robledo, Yaritza M.; Cumba-Avilés, Eduardo; Bernal, Guillermo
2018-01-01
Se examinó la prevalencia de experiencias atípicas psicóticas y cuasi-psicóticas y se identificaron factores asociados a éstas en 162 jóvenes puertorriqueños/as entre 13 y 17.5 años. Se evaluó la sintomatología depresiva, la ideación suicida, así como la presencia o historia de experiencias atípicas, eventos traumáticos y maltrato o abuso. Las experiencias atípicas estuvieron asociadas (p<.05) a ser fémina, a tener enfermedades físicas, a experimentar eventos traumáticos, a haber recibido tratamiento para la depresión, y a una sintomatología depresiva e ideación suicida elevada. Los eventos traumáticos, el tratamiento farmacológico para la depresión y la severidad de la ideación suicida fueron predictores significativos del número de experiencias reportadas. Los resultados confirman que la mayoría de las experiencias no son psicóticas. Se discuten las implicaciones para la evaluación y el tratamiento de jóvenes deprimidos/as.
Fuchs, Felipe C; Ribeiro, Jorge P; Fuchs, Flávio D; Wainstein, Marco V; Bergoli, Luis C; Wainstein, Rodrigo V; Zen, Vanessa; Kerkhoff, Alessandra C; Moreira, Leila B; Fuchs, Sandra C
2016-09-01
The importance of coronary anatomy in predicting cardiovascular events is well known. The use of traditional anatomical scores in routine angiography, however, has not been incorporated to clinical practice. SYNTAX score (SXscore) is a scoring system that estimates the anatomical extent of coronary artery disease (CAD). Its ability to predict outcomes based on a baseline diagnostic angiography has not been tested to date. To evaluate the performance of the SXscore in predicting major adverse cardiac events (MACE) in patients referred for diagnostic angiography. Prospective cohort of 895 patients with suspected CAD referred for elective diagnostic coronary angiography from 2008 to 2011, at a university-affiliated hospital in Brazil. They had their SXscores calculated and were stratified in three categories: no significant CAD (n = 495), SXscoreLOW-INTERMEDIATE: < 23 (n = 346), and SXscoreHIGH: ≥ 23 (n = 54). Primary outcome was a composite of cardiac death, myocardial infarction, and late revascularization. Secondary endpoints were the components of MACE and death from any cause. On average, patients were followed up for 1.8 ± 1.4 years. The primary outcome occurred in 2.2%, 15.3%, and 20.4% in groups with no significant CAD, SXscoreLOW-INTERMEDIATE, and SXscoreHIGH, respectively (p < 0.001). All-cause death was significantly higher in the SXscoreHIGH compared with the 'no significant CAD' group, 16.7% and 3.8% (p < 0.001), respectively. After adjustment for confounding factors, all outcomes remained associated with the SXscore. SXscore independently predicts MACE in patients submitted to diagnostic coronary angiography. Its routine use in this setting could identify patients with worse prognosis. A importância da anatomia coronariana na predição de eventos cardiovasculares é bem conhecida. O uso de escores anatômicos tradicionais na cineangiocoronariografia de rotina, entretanto, não foi incorporado à prática clínica. O SYNTAX escore (SXescore) é um sistema de escore que estima a extensão anatômica da doença arterial coronariana (DAC). Sua capacidade para predizer desfechos com base na cineangiocoronariografia diagnóstica de base ainda não foi testada. Avaliar o desempenho do SXescore para predizer eventos cardíacos adversos maiores (MACE) em pacientes encaminhados para cineangiocoronariografia diagnóstica. Coorte prospectiva de 895 pacientes com suspeita de DAC encaminhados para cineangiocoronariografia diagnóstica eletiva de 2008 a 2011, em hospital universitário no Brasil. Os pacientes tiveram seus SXescores calculados e foram estratificados em três categorias: 'sem DAC significativa' (n = 495); SXescoreBAIXO-INTERMEDIÁRIO: < 23 (n = 346); e SXescoreALTO: ≥ 23 (n = 54). O desfecho primário foi composto de morte cardíaca, infarto do miocárdio e revascularização tardia. Os desfechos secundários foram MACE e morte por todas as causas. Em média, os pacientes foram acompanhados por 1,8 ± 1,4 anos. Desfecho primário ocorreu em 2,2%, 15,3% e 20,4% nos grupos 'sem DAC significativa', SXescoreBAIXO-INTERMEDIÁRIO e SXescoreALTO, respectivamente (p < 0,001). Morte por todas as causas foi significativamente mais frequente no grupo de SXescoreALTO comparado ao grupo 'sem DAC significativa', 16,7% e 3,8% (p < 0,001), respectivamente. Após ajuste para fatores de confusão, todos os desfechos permaneceram associados com o SXescore. O SXescore prediz independentemente MACE em pacientes submetidos a cineangiocoronariografia diagnóstica. Seu uso rotineiro nesse contexto poderia identificar pacientes de pior prognóstico.
The Douro estuarine plume: Detection, processes and dynamics =
NASA Astrophysics Data System (ADS)
Mendes, Renato Paulo dos Santos
O Douro e um dos maiores rios da Peninsula Iberica, constituindo a maior descarga de agua doce para o Oceano Atlântico na costa noroeste portuguesa. A sua pluma estuarina tem particular relevância na dinâmica costeira e na modulacao de fenomenos biogeoquimicos. Sao objetivos desta dissertacao contribuir para a compreensao dos processos fisicos associados a geracao e propagacao da pluma estuarina do Rio Douro no oceano, assim como para o conhecimento dos seus padroes de dispersao e da forma como estes alteram a hidrologia e a circulacao costeira, considerando os agentes forcadores tipicos deste fenomeno (caudal fluvial, vento e mare) e indices climaticos relevantes. Para concretizacao destes objetivos foram desenvolvidas e aplicadas metodologias inovadoras de processamento de dados de detecao remota, assim como novas implementacoes estuarinas e costeiras de modelos numericos. Atraves de imagens MODIS, otimizadas para o estudo de fenomenos costeiros, efetuou-se uma detecao rigorosa da pluma. Identificou-se uma relacao entre o sinal turbido nLw555 e o caudal, demonstrando-se este produto como um bom proxy para a observacao da pluma no oceano. As escalas temporais e espaciais da pluma foram caraterizadas atraves destas imagens, combinadas com dados de caudal fluvial, mare, vento e precipitacao, e tambem com indices climaticos relevantes. Para compreender a propagacao da pluma e caracterizar a sua dinâmica e impacto na circulacao costeira, foi desenvolvida uma aplicacao 3D de modelos estuarinos e costeiros com malhas aninhadas de resolucao variavel. Definiramse e analisaram-se diferentes cenarios de vento e descarga fluvial. A interacao da pluma do Rio Douro e do Minho foi ainda analisada atraves dos resultados de simulacoes baseadas num evento de inverno. Os compositos turbidos mostraram que a pluma e facilmente detetada quando o caudal e maior que 500 m3 s??1. A descarga fluvial e o vento sao os principais forcadores da sua propagacao, enquanto a mare e apenas importante na regiao proxima a embocadura do estuario. Observaram-se relacoes a uma escala interanual entre a turbidez da pluma e os indices climaticos East Atlantic e NAO, com uma correlacao maxima identificada com 1 e 3 meses de desfasamento, respetivamente. Com base nos resultados das simulacoes efetuadas, a pluma e classificada como de larga escala e de advecao superficial, apresentando caracteristicas de uma pluma prototipica. Em condicoes de caudal moderado a elevado, a descarga estuarina e suficiente para gerar uma corrente costeira para norte sem acao do vento. Em eventos de ventos leste, a propagacao da pluma e similar ao caso sem vento, com um aumento da velocidade da corrente. Uma corrente costeira para sul e unicamente identificada sob condicoes de forte vento de oeste. Ventos de norte tendem a estender a pluma para o largo, com uma inclinacao na direcao sudoeste, enquanto ventos de sul intensificam a corrente para norte, sendo a mistura das plumas do Douro e do Minho uma consequencia possivel. A analise desta interacao apontou a contribuicao do Douro como importante na estabilizacao da WIBP e nas trocas de agua entre o oceano e as Rias Baixas. A interacao da pluma do Douro com estuarios localizados a sul da sua foz e a confirmacao in situ da recirculacao observada nos resultados numericos afiguram-se como temas relevantes para investigacoes futuras. None
Quick Tips for Small Manufacturing Businesses Spanish Translation
Empresas pequeñas de manufactura que cumplen con regulaciones ambientales e implementan buenas practicas de manejo, pueden mantenerse a la vanguardia respecto a prepararse para eventos climáticos extremos en el futuro.
Cuban Telecommunications, Computer Networking, and U.S. Policy Implications,
1996-07-01
Informacion para la Prensa Federacion de Mujeres Cubanas Grupo para la Educacion sobre el SIDA Instituto Superior Latinoamericano de Ajedrez...DIR) Informacion sobre Medio Ambiente (DIR) Medicina Alternativa (DIR) Servicio Especial de la Mujer (DIR) Eventos Internacionales (DIR
Terapia fibrinolítica sistêmica no tromboembolismo pulmonar
Ceresetto, José Manuel; Marques, Marcos Arêas
2017-01-01
Resumo O tromboembolismo pulmonar permanece como um grande desafio terapêutico para os médicos especialistas, pois, apesar de todo investimento e desenvolvimento em seu diagnóstico, profilaxia e tratamento, essa condição continua sendo a principal causa de morte evitável em ambiente hospitalar. Ainda restam muitas dúvidas em relação a qual perfil de paciente vai se beneficiar de fato da terapia fibrinolítica sistêmica, sem ficar exposto a um grande risco de sangramento. A estratificação de risco e a avaliação do prognóstico do evento, através de escores clínicos de insuficiência ventricular direita, marcadores de dilatação e disfunção do ventrículo direito e avaliação da massa trombótica, associados ou de forma isolada, são ferramentas que podem auxiliar na identificação do paciente que irá se beneficiar dessa terapia. Os únicos consensos em relação à terapia fibrinolítica no tratamento do tromboembolismo pulmonar são: não deve ser indicada de forma rotineira; nenhum dos escores ou marcadores, isoladamente, devem justificar seu uso; e os pacientes com instabilidade hemodinâmica são os mais beneficiados. Além disto, deve-se avaliar cada caso em relação ao risco de sangramento, especialmente no sistema nervoso central. PMID:29930636
Eventos de Noviembre (November Events).
ERIC Educational Resources Information Center
Pla, Myrna; Toro, Leonor
Written in Spanish, this booklet contains information on three events occurring in the month of November: Armistice Day (November 11), the discovery of Puerto Rico (November 19), and Thanksgiving (last Thursday in November). Following a brief discussion of "Dia del Armisticio" (Armistice Day), first celebrated on November 11, 1919, the…
Eventos de Octubre (October Events).
ERIC Educational Resources Information Center
Pla, Myrna; Toro, Leonor
Written in Spanish, this booklet contains information on three events occurring in the month of October: the discovery of America (October 12), the organization of the United Nations (October 24), and Halloween (October 31). Christopher Columbus' journey to America is discussed through a short story; an epic poem ("Velas Epicas"); and…
Eventos de Marzo (March Events).
ERIC Educational Resources Information Center
Toro, Leonor
Designed for teachers, this booklet, written in Spanish, contains information on seven March events: La Ley Jones; Pachin Marin; San Patricio; Primavera; Luis Pales Matos; La Masacre de Ponce; and La Esclavitud. The first section provides an overview of the Ley Jones, which introduced the bill of rights and made American citizenship obligatory for…
Eventos de Julio (July Events).
ERIC Educational Resources Information Center
Pla, Myrna; Toro, Leonor
Written in Spanish, this booklet contains brief information on 10 July events celebrated by Puerto Ricans: United States Declaration of Independence; the birthdays of P.T. Barnum, Elias Howe, John Quincy Adams, Luis Munoz Rivera, and Simon Bolivar; Marisol Malaret (first puerto Rican to be "Miss Universe"); Puerto Rican Constitution; Las…
Eventos de Septiembre (September Events).
ERIC Educational Resources Information Center
Toro, Leonor, Ed.
Written in Spanish, this booklet contains brief information on 10 September events celebrated by Puerto Ricans: Arturo Somohano, the beginning of the academic year, Dia del Trabajo (Labor Day), Pedro Albizu Campos, Lola Rodriguez de Tio, William Howard Taft, El Grito de Lares, Dia del Indio Americano (American Indian Day), las retretas, and…
Eventos de Junio (June Events).
ERIC Educational Resources Information Center
Pla, Myrna; Toro, Leonor
Written in Spanish, this booklet contains brief information on six June events celebrated by Puerto Ricans: Nathan Hale, Dia de la Bandera (Flag Day), Francisco Oller, Dia de los Padres (Father's Day), Fiesta de San Juan Bautista, and school graduation. Designed for teachers, the booklet includes a listing of 16 historical events occurring in…
Eventos de Agosto (August Events).
ERIC Educational Resources Information Center
Toro, Leonor; Pla, Myrna
Written in Spanish, this booklet contains brief information on seven August events celebrated by Puerto Ricans: Herbert Hoover's birthdate (August 10); Acta del Seguro Social (Social Security Act, August 14); Julian E. Blanco (August 14), Enmienda 19 Sufragia de la Mujer (Amendment 19, Women's Suffrage, August 26); Benjamin Harrison (August 20);…
Eventos de Abril (April Events).
ERIC Educational Resources Information Center
Toro, Leonor; Pla, Myrna
Designed for teachers, this booklet, written in Spanish, contains information on nine April events: Dia de los Tontos; Pascua de Resurreccion; Thomas Jefferson; Jose de Diego; Rosendo Matienzo Cintron; James Buchanan; Ulysses S. Grant; James Monroe; and Dia del Arbol. An overview of Dia de los Tontos is provided. Following brief descriptions of…
Eventos de Diciembre (December Events).
ERIC Educational Resources Information Center
Pla, Myrna; Toro, Leonor
Written in Spanish, this booklet contains information on three events occurring in the month of December: winter, Christmas, and New Year's Eve. Winter is briefly discussed. The section on Christmas includes a short story ("La Nochebuena"); a poem about Christmas in Puerto Rico; a legend about the poinsettia; brief discussion of Santa…
Eventos de Febrero (February Events).
ERIC Educational Resources Information Center
Toro, Leonor; Pla, Myrna
Designed as a resource for teachers, the booklet contains brief information on eight events celebrated by Puerto Ricans in the month of February: La Candelaria; Abraham Lincoln; Black History; Valentine's Day; Julia de Burgos; Luis Munoz Marin; George Washington; and the Carnaval. Written in Spanish, the booklet discusses the orgin and ways of…
Proprioception in the extraocular muscles of mammals and man.
Blumer, Roland; Konacki, Kadriye Zeynep; Streicher, Johannes; Hoetzenecker, Wolfram; Blumer, Michael Josef Franz; Lukas, Julius-Robert
2006-06-01
This article summarizes the authors' previous studies on proprioceptors in extraocular muscles (EOMs) of mammals and man. They report on muscle spindles in the EOMs of man, Golgi tendon organs in the EOMs of even-toed ungulates, and palisade endings in the EOMs of the cat. Muscle spindles: Muscle spindles are present in the EOMs of some mammals and in the EOMs of man. Compared with muscle spindles in other skeletal muscles, those in human EOMs exhibit structural differences. These structural differences may indicate a special function. Golgi tendon organs: Golgi tendon organs are absent in human EOMs. Golgi tendon organs exhibiting a specific morphology are present in the EOMs of even-toed ungulates. Their high number and rich innervation indicate functional importance. Palisade endings: Palisade endings are nervous end organs confined to the EOMs of mammals and man. It is assumed that these organs have a proprioceptive function. The authors show that palisade endings are immunoreactive for antibodies against choline acetyltransferase. Neuromuscular contacts, if present in palisade endings, are alpha -bungarotoxin positive as well. Taken together, these results show that palisade endings exhibit molecular characteristics of effector organs.
Eventos de Enero (January Events).
ERIC Educational Resources Information Center
Pla, Myrna; Toro, Leonor
Written in Spanish, this booklet contains brief information on the origin of four events celebrated in the month of January in Puerto Rico and the United States: New Year (January 1), Dia de Reyes (January 6), Eugenio Maria de Hostos (January 11), and Martin Luther King (January 15). Designed as a resource for teachers to use in teaching the child…
ERIC Educational Resources Information Center
Toro, Leonor; Pla, Myrna
Designed as a resource for teachers, this booklet, written in Spanish, contains brief information on seven May events: La Semana de la Educacion (first Friday in May), Harry S. Truman (May 8), Dia de las Madres (second Sunday in May), Luis Llorens Torres (May 14), La Cruz Roja (May 21), John F. Kennedy (May 29), and El Dia De Conmemoracion (May…
Research on large area VUV-sensitive gaseous photomultipliers for cryogenic applications
NASA Astrophysics Data System (ADS)
Coimbra, Artur Emanuel Cardoso
Desde cedo que a comunidade cientifica compreendeu que gases nobres em liquido sao excelentes meios de deteccao de radiacao, combinando a sua elevada densidade, elevado grau de homogeneidade e de elevado rendimento de cintilacao. Para alem destas caracteristicas inerentes, estes tem a potencialidade de fornecer ambos sinais de ionizacao - criando electroes livres - e cintilacao em resposta a interaccao com radiacao ionizante e, tendo em vista a sua aplicacao em experiencias de eventos raros relacionados com fisica de neutrinos ou materia-escura, a capacidade de autoblindagem garante a exclusao de eventos induzidos por radiacao de fundo. O facto de nao absorverem a sua propria luz, emergente dos eventos de cintilacao, permite a expansao deste tipo de detectores ate grandes volumes, sendo que as colaboracoes mais recentes propoem detectores com dezenas de toneladas de xenon em estado liquido. As experiencias actuais que usam gases nobres em estado liquido empregam xenon ou argon numa so fase (estado liquido) ou em dupla-fase (estado liquido + gasoso) e as suas aplicacoes abrangem desde as ja referidas experiencias de procura de eventos raros, passando por imagiologia medica tais como detectores de radiacao gama para PET ou câmaras Compton "3-gamma" em combinacao com PET, passando tambem por aplicacoes de seguranca como sistemas de inspeccao para deteccao de material fissil e, finalmente, em câmaras Compton para aplicacoes de astrofisica. Em ambas as configuracoes a leitura dos sinais de cintilacao e geralmente feita atraves de um grande numero de dispendiosos fotomultiplicadores de vacuo agrupados. A presente tese de doutoramento e dedicada aos fotomultiplicadores gasosos de grande area para aplicacoes criogenicas desenvolvidos no contexto do programa doutoral, tendo em vista a sua eventual aplicacao como um dispositivo complementar aos metodos existentes de deteccao de cintilacao, para aplicacao em futuras experiencias de grande escala. Esta pesquisa foi direccionada tendo em vista o desenvolvimento de eficientes fotomultiplicadores gasosos de grande area, potencialmente mais economicos por unidade de area, baseados em "Thick Gas-Electron Multipliers" (THGEMs). Combinando fotocatodos de alta eficiencia com multiplicadores gasosos de electroes capazes de atingir elevado ganho em carga obteve-se assim um dispositivo com elevada sensibilidade para a deteccao de fotoes unicos, com a possibilidade de discriminacao em posicao com resolucao espacial inferior a um milimetro e com resolucao temporal da ordem de poucos nano segundos. Contrariamente ao que sucede com a tecnologia de vacuo actualmente, com este dispositivo a localizacao em posicao de fotoes em grandes areas e feita num unico dispositivo integrando electronica habitualmente utilizada em experiencias de rastreamento de particulas. Neste trabalho o fotomultiplicador gasoso desenvolvido consiste numa cadeia de THGEMs combinados com um fotocatodo de iodeto de cesio (CsI) sensivel ao ultravioleta enquanto que os testes criogenicos foram realizados na Time Projection Chamber (TPC) de dupla fase de xenon liquido recentemente desenvolvida no Weizmann Institute of Science (WILiX). (Abstract shortened by ProQuest.).
1984-08-07
never constructive , A calm and thorough dis- cussion of these issues should deal first with this evaluation of the threat and the means of...end with only a few statements (or even a few commitments) concerning the joint construction of this or that materiel. As useful and even...to a statement made by Fernando de Caralt, president of Construcciones Aeronauticas, S. A. (CAS), yesterday at a meeting of stockhold- ers, the
Propriedades de estruturas temporais rápidas submilimétricas durante uma grande explosão solar
NASA Astrophysics Data System (ADS)
Raulin, J.-P.; Kaufmann, P.; Gimenez de Castro, C. G.; Pacini, A. A.; Makhmutov, V.; Levato, H.; Rovira, M.
2003-08-01
Apresentamos novas propriedades de variações rápidas da emissão submilimétrica durante uma das maiores explosões solares do ciclo solar 23. Os dados analisados neste estudo foram obtidos com o Telescópio Solar Submilimétrico (SST), que observa o Sol em 212 GHz e 405 GHz, e comparados com emissões em Raios-X duros e Raios-gama (fótons de energia > 10 MeV), que foram obtidas pelo experimento GRS do Yohkoh. Aplicamos diferentes metodologias para detectar e caracterizar, ao longo do evento, os pulsos submilimétricos (duração de 50-300 ms) detectados acima de uma componente mais lenta (alguns minutos). Os resultados mostram que durante a fase impulsiva, num instante próximo ao tempo do máximo do evento, houve um aumento da ocorrência de maiores e de mais rápidas estruturas temporais. Também identificamos uma boa correlação com as emissões em raios-X e raios-gama (até a faixa de energia 10-100 MeV), indicando que os pulsos rápidos submilimétricos refletiram injeções primárias de energia durante o evento.O espectro do fluxo desses pulsos é crescente com a freqüência entre 212 and 405 GHz, na maioria dos casos, ao contrário do observado para a componente gradual. As posições calculadas para as estruturas rápidas são discretas, compactas e localizadas em toda a área da região ativa, o que é previsto nos modelos de explosões solares decorrentes de instabilidades múltiplas em diferentes pequenas regiões. Por outro lado, a posição calculada para a componente lenta é estável durante a fase impulsiva. Assim, a comparação entre as características do espectro de fluxo e da localização da emissão, para os pulsos rápidos e para a componente gradual, sugere que as respectivas emissões são de natureza diferente.
Grützenmacher, S; Robinson, D M; Sevecke, J; Mlynski, G; Beule, A G
2011-03-01
Knowledge of airflow in animal noses is sparse. Such knowledge could be important for selection of animal models used in environmental studies. From the phylogenetic and ontogenetic point of view, a comparison between the animal and human nose is interesting. Nose models of 5 even-toed ungulate species (he-goat, sheep, cow, roebuck, wild boar) and two humans (new born infant and adult) were examined. Anatomical and physiological features of the nasal cavities of all species were compared. All models were rinsed with water and the flow was visualized for observation. Geometric and rhinoresistometric measurements were then performed. Even-toed ungulates have two turbinates directly in the main part of the nasal airflow (respiratory turbinates) and a different number of turbinates in a so-called dead space of the nasal airflow above the nasopharyngeal duct (ethmoidal turbinates). The latter correspond with the upper and middle turbinate in analogy to the human nose. Respiratory turbinates of even-toed ungulates insert immediately behind the external nasal ostium. Thus, the whole nasal cavity acts as a functional area with the exception of a small area acting as dead space only detectable in ruminants, possibly indicating a small evolutionary progress from suinae to bovidae. The shape of the animal nasal cavity is stretched and flat. The airflow runs nearly completely turbulent through the nose. The nasal cavity in the adult human is relatively short and high. The area between the external nasal ostium and the head of the inferior turbinate is called inflow area. It distributes the airflow over the whole nasal cross section and generates a turbulent flow. So the airflow is prepared to contact the mucosa in the functional area (turbinate area). The morphology of the inflow area is approximately formed by the shape of the external nose. The nasal cavity of a newborn child is also stretched and flat and more similar to the nasal shape of the investigated animals. The inflow area in the newborn nose is not yet developed and corresponds with the growing external newborn nose. One can hypothesize that the inflow area in human noses is a morphological adaptation in the changed length-height-ratio of the nasal cavity.
R. Kasten Dumroese; Douglass F. Jacobs; Kim M. Wilkinson
2012-01-01
El cultivo de plantines en contenedor no tiene principio ni final; es un ciclo continuo de eventos que se repiten. Todos los aspectos de la producción son importantes y ningún detalle es menos relevante que los demás. Iniciar la producción de los plantines de forma adecuada asegura la obtención de plantas saludables y de buena calidad para la plantación a campo. En...
Meneguz-Moreno, Rafael Alexandre; Costa, José de Ribamar; Moscoso, Freddy Antônio Britto; Staico, Rodolfo; Tanajura, Luiz Fernando Leite; Centemero, Marinella Patrizia; Chaves, Auréa Jacob; Abizaid, Andrea Claudia Leão de Sousa; Sousa, Amanda Guerra de Moraes Rego E; Abizaid, Alexandre Antonio Cunha
2017-02-01
Bioresorbable vascular scaffolds (BVS) were developed to improve the long-term results of percutaneous coronary intervention, restoring vasomotion. To report very late follow-up of everolimus-eluting Absorb BVS (Abbott Vascular, Santa Clara, USA) in our center. Observational retrospective study, in a single Brazilian center, from August 2011 to October 2013, including 49 patients submitted to Absorb BVS implantation. Safety and efficacy outcomes were analyzed in the in-hospital and very late follow-up phases (> 2 years). All 49 patients underwent a minimum follow-up of 2.5 years and a maximum of 4.6 years. Mean age was 56.8 ± 7.6 years, 71.4% of the patients were men, and 26.5% were diabetic. Regarding clinical presentation, the majority (94%) had stable angina or silent ischemia. Device success was achieved in 100% of cases with 96% overall procedure success rate. Major adverse cardiovascular events rate was 4% at 30 days, 8.2% at 1 year, and 12.2% at 2 years, and there were no more events until 4.6 years. There were 2 cases of thrombosis (1 subacute and 1 late). In this preliminary analysis, Absorb BVS showed to be a safe and effective device in the very late follow-up. Establishing the efficacy and safety profiles of these devices in more complex scenarios is necessary. Os suportes vasculares bioabsorvíveis (SVB) foram desenvolvidos com o intuito de melhorar os resultados da intervenção coronária percutânea a longo prazo, restabelecendo-se a vasomotricidade. Reportar o seguimento muito tardio do implante do SVB eluidor de everolimus Absorb® (Abbot Vascular, Santa Clara, EUA) em nosso centro. Estudo observacional, retrospectivo, em um único centro brasileiro, que incluiu 49 pacientes submetidos ao implante do SVB Absorb® entre agosto/2011 e outubro/2013. Foram analisados os desfechos de segurança e eficácia na fase hospitalar e bastante tardia (> 2 anos). Todos os 49 pacientes completaram um seguimento mínimo de 2,5 anos, sendo o máximo de 4,6 anos. A média de idade foi 56,8 ± 7,6 anos, sendo 71,4% da população estudada do sexo masculino e 26,5% composta por diabéticos. Considerando a apresentação clínica, a grande maioria (94%) tinha angina estável ou isquemia silenciosa. Obteve-se sucesso do dispositivo em 100% dos casos e do procedimento, em 96%. A taxa de eventos cardiovasculares maiores foi de 4% aos 30 dias, de 8,2% em 1 ano, e de 12,2% em 2 anos, sem mais eventos até 4,6 anos. Houve 2 casos de trombose (1 subaguda e 1 tardia) até o último seguimento. Nesta análise preliminar, o uso do SVB Absorb® mostrou-se seguro e eficaz no seguimento bastante tardio. Faz-se necessário estabelecer o perfil de eficácia e segurança destes dispositivos em cenários de maior complexidade.
Araujo, Ana Carla Pereira de; Santos, Bruno F de Oliveira; Calasans, Flavia Ricci; Pinto, Ibraim M Francisco; Oliveira, Daniel Pio de; Melo, Luiza Dantas; Andrade, Stephanie Macedo; Tavares, Irlaneide da Silva; Sousa, Antonio Carlos Sobral; Oliveira, Joselina Luzia Menezes
2014-11-01
Background: Studies have demonstrated the diagnostic accuracy and prognostic value of physical stress echocardiography in coronary artery disease. However, the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia is limited. Objective: To evaluate the effectiveness of physical stress echocardiography in the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia. Methods: This is a retrospective cohort in which 866 consecutive patients with exercise test positive for myocardial ischemia, and who underwent physical stress echocardiography were studied. Patients were divided into two groups: with physical stress echocardiography negative (G1) or positive (G2) for myocardial ischemia. The endpoints analyzed were all-cause mortality and major cardiac events, defined as cardiac death and non-fatal acute myocardial infarction. Results: G2 comprised 205 patients (23.7%). During the mean 85.6 ± 15.0-month follow-up, there were 26 deaths, of which six were cardiac deaths, and 25 non-fatal myocardial infarction cases. The independent predictors of mortality were: age, diabetes mellitus, and positive physical stress echocardiography (hazard ratio: 2.69; 95% confidence interval: 1.20 - 6.01; p = 0.016). The independent predictors of major cardiac events were: age, previous coronary artery disease, positive physical stress echocardiography (hazard ratio: 2.75; 95% confidence interval: 1.15 - 6.53; p = 0.022) and absence of a 10% increase in ejection fraction. All-cause mortality and the incidence of major cardiac events were significantly higher in G2 (p < 0. 001 and p = 0.001, respectively). Conclusion: Physical stress echocardiography provides additional prognostic information in patients with exercise test positive for myocardial ischemia.Fundamento: Estudos têm demonstrado a acurácia diagnóstica e o valor prognóstico da ecocardiografia com estresse físico na doença arterial coronária, mas a predição de mortalidade e de eventos cardíacos maiores, em pacientes com teste ergométrico positivo para isquemia miocárdica, é limitada. Objetivo: Avaliar a predição de mortalidade e de eventos cardíacos maiores pela ecocardiografia com estresse físico em pacientes com teste ergométrico positivo para isquemia miocárdica. Métodos: Trata-se de uma coorte retrospectiva em que foram estudados 866 pacientes consecutivos, com teste ergométrico positivo para isquemia miocárdica, submetidos à ecocardiografia com estresse físico. Os pacientes foram divididos em dois grupos: ecocardiografia com estresse físico negativa (G1) ou positiva (G2) para isquemia miocárdica. Os desfechos avaliados foram mortalidade por qualquer causa e eventos cardíacos maiores, definidos como óbito cardíaco e infarto agudo do miocárdio não fatal. Resultados: O G2 constituiu-se de 205 (23,7%) pacientes. Durante o seguimento médio de 85,6 ± 15,0 meses, ocorreram 26 óbitos, sendo seis por causa cardíaca, e 25 casos de infarto agudo do miocárdio não fatais. Os preditores independentes de mortalidade foram idade, diabetes melito e a ecocardiografia com estresse físico + (hazard ratio: 2,69; intervalo de confiança de 95%: 1,20 - 6,01; p = 0,016), com os seguintes eventos cardíacos maiores: idade, doença arterial coronária prévia, ecocardiografia com estresse físico + (hazard ratio: 2,75; intervalo de confiança de 95%: 1,15 - 6,53; p = 0,022) e ausência do incremento de 10% na fração de ejeção. A mortalidade por qualquer causa e os eventos cardíacos maiores foram significativamente superiores no G2 (p < 0, 001 e p = 0,001, respectivamente). Conclusão: A ecocardiografia com estresse físico oferece informações prognósticas adicionais em pacientes com teste ergométrico positivo para isquemia miocárdica.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magana-Mendoza, Leonel
1997-10-01
La medicion de la distribucion de momento longitudinal en eventos pmore » $$\\bar{p}$$ → Z → e +e -constituye una prueba para las parametrizaciones de las funciones de distribucion partonica, al mismo tiempo que proporciona un nuevo conjunto de datos que pueden ser empleados como parametros de entrada en los ajustes globales encaminados a mejorar dichas parametrizaciones.« less
NASA Astrophysics Data System (ADS)
Paissan, G.; Stenborg, G.; Rovira, M.
Se conocen tres diferentes fenómenos de gran escala que ocurren en la atmósfera solar, denominados eyecciones coronales de masa (ECMs), protuberancias eruptivas y grandes fulguraciones de dos bandas. Estos fenómenos están estrechamente relacionados y podrían ser distintas manifestaciones de un único proceso físico. Las ECMs son definidas como eyecciones de gran escala de masa y flujo magnético desde la baja corona al espacio interplanetario. Desde su descubrimiento en los '70, muchos modelos han sido propuestos para explicar su origen y evolución. La explicación física de las ECMs es un tema de debate intenso. No obstante, los modelos pueden sintetizarse en dos grandes grupos: 1) los modelos de inyección de flujo y 2) los modelos de almacenamiento y liberación. En este trabajo, se presentan los estudios realizados con una serie de eventos observados con el coronógrafo MICA (Mirror Coronograph for Argentina), el telescopio en H-alfa HASTA (H-alpha Solar Telescope for Argentina) y los coronógrafos C2 y C3 de la sonda SOHO (Solar and Heliospheric Observatory). Los eventos que pudieron ser identificados como ECMs son contrastados dentro del esquema de los dos paradigmas teóricos propuestos.
Pivatto Junior, Fernando; Scheffel, Rafael Selbach; Ries, Lucas; Wolkind, Ricardo Roitman; Marobin, Roberta; Barkan, Sabrina Sigal; Amon, Luís Carlos; Biolo, Andréia
2017-04-01
The SAMe-TT2R2 score was developed to predict which patients on oral anticoagulation with vitamin K antagonists (VKAs) will reach an adequate time in therapeutic range (TTR) (> 65%-70%). Studies have reported a relationship between this score and the occurrence of adverse events. To describe the TTR according to the score, in addition to relating the score obtained with the occurrence of adverse events in patients with nonvalvular atrial fibrillation (AF) on oral anticoagulation with VKAs. Retrospective cohort study including patients with nonvalvular AF attending an outpatient anticoagulation clinic of a tertiary hospital. Visits to the outpatient clinic and emergency, as well as hospital admissions to the institution, during 2014 were evaluated. The TTR was calculated through the Rosendaal´s method. We analyzed 263 patients (median TTR, 62.5%). The low-risk group (score 0-1) had a better median TTR as compared with the high-risk group (score ≥ 2): 69.2% vs. 56.3%, p = 0.002. Similarly, the percentage of patients with TTR ≥ 60%, 65% or 70% was higher in the low-risk group (p < 0.001, p = 0.001 and p = 0.003, respectively). The high-risk group had a higher percentage of adverse events (11.2% vs. 7.2%), although not significant (p = 0.369). The SAMe-TT2R2 score proved to be effective to predict patients with a better TTR, but was not associated with adverse events. O escore SAMe-TT2R2 foi desenvolvido visando predizer quais pacientes em anticoagulação oral com antagonistas da vitamina K (AVKs) atingirão um tempo na faixa terapêutica (TFT) adequado (> 65%-70%) no seguimento. Estudos também o relacionaram com a ocorrência de eventos adversos. Descrever o TFT de acordo com o escore, além de relacionar a pontuação obtida com a ocorrência de eventos adversos adversos em pacientes com fibrilação atrial (FA) não valvar em anticoagulação oral com AVKs. Estudo de coorte retrospectivo incluindo pacientes com FA não valvar em acompanhamento em ambulatório de anticoagulação de um hospital terciário. Foi realizada uma avaliação retrospectiva de consultas ambulatoriais, visitas a emergência e internações hospitalares na instituição no período de janeiro-dezembro/2014. O TFT foi calculado aplicando-se o método de Rosendaal. Foram analisados 263 pacientes com TFT mediano de 62,5%. O grupo de baixo risco (0-1 ponto) obteve um TFT mediano maior em comparação com o grupo de alto risco (≥ 2 pontos): 69,2% vs. 56,3%, p = 0,002. Da mesma forma, o percentual de pacientes com TFT ≥ 60%, 65% ou 70% foi superior nos pacientes de baixo risco (p < 0,001, p = 0,001 e p = 0,003, respectivamente). Os pacientes de alto risco tiveram um percentual maior de eventos adversos (11,2% vs. 7,2%), embora não significativo (p = 0,369). O escore SAMe-TT2R2 foi uma ferramenta eficaz na predição do TFT em pacientes com FA em uso de AVKs para anticoagulação, porém não se associou à ocorrência de eventos adversos.
ANALYSIS OF BIOMECHANICAL PARAMETERS IN COLONIC ANASTOMOSIS.
Iwanaga, Tiago Cavalcanti; Aguiar, José Lamartine de Andrade; Martins-Filho, Euclides Dias; Kreimer, Flávio; Silva-Filho, Fernando Luiz; Albuquerque, Amanda Vasconcelos de
2016-01-01
The use of measures in colonic anastomoses to prevent dehiscences is of great medical interest. Sugarcane molasses, which has adequate tolerability and compatibility in vivo, has not yet been tested for this purpose. To analyze the biomechanical parameters of colonic suture in rats undergoing colectomy, using sugarcane molasses polysaccharide as tape or gel. 45 Wistar rats (Rattus norvegicus albinus) were randomized into three groups of 15 animals: irrigation of enteric sutures with 0.9% saline solution; application of sugarcane molasses polysaccharide as tape; and sugarcane molasses polysaccharide as gel. The rats underwent colon ressection, with subsequent reanastomosis using polypropylene suture; they were treated according to their respective groups. Five rats from each group were evaluated at different times after the procedure: 30, 90 and 180 days postoperatively. The following variables were evaluated: maximum rupture force, modulus of elasticity and specific deformation of maximum force. The biomechanical variables among the scheduled times and treatment groups were statistically calculated. The characteristics of maximum rupture force and modulus of elasticity of the specimens remained identical, regardless of treatment with saline, polysaccharide gel or tape, and treatment time. However, it was found that the specific deformation of maximum force of the intestinal wall was higher after 180 days in the group treated with sugarcane polysaccharide gel (p=0.09). Compared to control, it was detected greater elasticity of the intestinal wall in mice treated with sugarcane polysaccharide gel, without changing other biomechanical characteristics, regardless of type or time of treatment. A aplicação de produtos em anastomoses colônicas que possam prevenir o surgimento de deiscências são de grande interesse médico. O emprego do polissacarídeo de melaço de cana-de-açúcar (Saccharum officinarum), que possui adequada tolerabilidade e compatibilidade in vivo, ainda não foi testado para este fim. Analisar os parâmetros biomecânicos em suturas colônicas de ratos submetidos à colectomia esquerda após aplicação de fita ou gel do polissacarídeo do melaço da cana-de-açúcar no sítio cirúrgico. Quarenta e cinco ratos (Rattus norvegicus albinus da linhagem Wistar) foram sorteados em três grupos de 15 submetidos a: irrigação das suturas entéricas com soro fisiológico a 0,9%; aplicação de fita de polissacarídeo do melaço da cana-de-açúcar; e aplicação do gel do mesmo melaço. Os ratos foram submetidos à colectomia esquerda com anastomose primária, e tratados segundo os respectivos grupos. Cinco ratos de cada grupo foram avaliados em diferentes tempos após o procedimento: 30º, 90º e 180º dias de pós-operatório. Foram avaliadas as variáveis de força máxima de ruptura, módulo de elasticidade e deformação específica da força máxima. As variáveis biomecânicas entre os tempos de coleta da pesquisa e os grupos de tratamento foram analisados estatisticamente. As características biomecânicas de força máxima de ruptura e o módulo de elasticidade do corpo de prova permaneceram idênticas, independente do tratamento com soro, fita ou gel de polissacarídeo, e do tempo de tratamento. No entanto, foi evidenciada maior deformação específica da força máxima da parede intestinal, aos 180 dias nos ratos tratados com gel de polissacarídeo de cana-de-açúcar. (p=0,09). Em relação ao controle, foi detectada maior elasticidade da parede intestinal nos ratos tratados com gel de polissacarídeo de cana-de-açúcar, sem alteração de outras características biomecânicas, independente do tipo ou tempo de tratamento.
Las marismas costeras proporcionan numerosos beneficios a los ecosistemas, incluyendo la proporción del hábitat de la flora y fauna, la protección de las zonas costeras contra inundaciones durante eventos extremos, mejoran la calidad del agua para las almejas y ostras a través de...
Spontaneous pneumomediastinum: experience in 18 patients during the last 12 years.
Dionísio, Patrícia; Martins, Luís; Moreira, Susana; Manique, Alda; Macedo, Rita; Caeiro, Fátima; Boal, Luísa; Bárbara, Cristina
2017-01-01
To characterize clinically all of the patients with spontaneous pneumomediastinum (SPM) admitted to an adult pulmonology ward in Lisbon, Portugal. This was a retrospective descriptive study of all adult patients (≥ 18 years of age) diagnosed with SPM between January of 2004 and September of 2015. At least one predisposing factor was identified in most (88.9%) of the 18 patients who presented with SPM during the study period. With regard to precipitating factors, bouts of cough were present in 50.0% of the patients. Other precipitating factors included a sudden increase in tobacco consumption, inhaled drug use, occupational inhalation of varnish fumes, intense exercise, and vomiting. The most common complaints were dyspnea (in 83.3%) and chest pain (in 77.8%). Other complaints included cough, neck pain, dysphagia, and odynophagia. Subcutaneous emphysema was found in most of the patients. The diagnosis of SPM was based on chest X-ray findings in 61.1% of the patients. Although SPM is a rare condition, it should be considered in the differential diagnosis of chest pain and dyspnea. It can develop without a triggering event or conclusive findings on a chest X-ray, which is usually sufficient for diagnosis. Caracterizar clinicamente todos os pacientes com pneumomediastino espontâneo (PME) admitidos em uma enfermaria de pneumologia para adultos em Lisboa, Portugal. Estudo descritivo retrospectivo no qual foram analisados todos os pacientes adultos (≥ 18 anos de idade) com diagnóstico de PME entre janeiro de 2004 e setembro de 2015. Pelo menos um fator predisponente foi identificado na maioria (isto é, em 88,9%) dos 18 pacientes que apresentaram PME durante o período de estudo. No tocante a fatores precipitantes, crises de tosse ocorreram em 50,0% dos pacientes. Outros fatores precipitantes foram um aumento repentino do consumo de tabaco, uso de drogas inalatórias, inalação ocupacional de vapores de vernizes, exercício intenso e vômitos. As queixas mais comuns foram dispneia (em 83,3%) e dor torácica (em 77,8%). Outras queixas foram tosse, cervicalgia, disfagia e odinofagia. Constatou-se a presença de enfisema subcutâneo na maioria dos pacientes. O diagnóstico de PME baseou-se na radiografia de tórax em 61,1% dos pacientes. Embora seja uma doença rara, o PME deve ser levado em conta no diagnóstico diferencial de dor torácica e dispneia. O PME pode surgir sem um evento desencadeante e sem achados conclusivos na radiografia de tórax, que é geralmente suficiente para o diagnóstico.
Cesena, Fernando Henpin Yue; Laurinavicius, Antonio Gabriele; Valente, Viviane A; Conceição, Raquel D; Santos, Raul D; Bittencourt, Marcio S
2017-06-01
There is controversy whether management of blood cholesterol should be based or not on LDL-cholesterol (LDL-c) target concentrations. To compare the estimated impact of different lipid-lowering strategies, based or not on LDL-c targets, on the risk of major cardiovascular events in a population with higher cardiovascular risk. We included consecutive individuals undergoing a routine health screening in a single center who had a 10-year risk for atherosclerotic cardiovascular disease (ASCVD) ≥ 7.5% (pooled cohort equations, ACC/AHA, 2013). For each individual, we simulated two strategies based on LDL-c target (≤ 100 mg/dL [Starget-100] or ≤ 70 mg/dL [Starget-70]) and two strategies based on percent LDL-c reduction (30% [S30%] or 50% [S50%]). In 1,897 subjects (57 ± 7 years, 96% men, 10-year ASCVD risk 13.7 ± 7.1%), LDL-c would be lowered from 141 ± 33 mg/dL to 99 ± 23 mg/dL in S30%, 71 ± 16 mg/dL in S50%, 98 ± 9 mg/dL in Starget-100, and 70 ± 2 mg/dL in Starget-70. Ten-year ASCVD risk would be reduced to 8.8 ± 4.8% in S50% and 8.9 ± 5.2 in Starget-70. The number of major cardiovascular events prevented in 10 years per 1,000 individuals would be 32 in S30%, 31 in Starget-100, 49 in S50%, and 48 in Starget-70. Compared with Starget-70, S50% would prevent more events in the lower LDL-c tertile and fewer events in the higher LDL-c tertile. The more aggressive lipid-lowering approaches simulated in this study, based on LDL-c target or percent reduction, may potentially prevent approximately 50% more hard cardiovascular events in the population compared with the less intensive treatments. Baseline LDL-c determines which strategy (based or not on LDL-c target) is more appropriate at the individual level. Há controvérsias sobre se o controle do colesterol plasmático deve ou não se basear em metas de concentração de colesterol LDL (LDL-c). Comparar o impacto estimado de diferentes estratégias hipolipemiantes, baseadas ou não em metas de LDL-c, sobre o risco de eventos cardiovasculares maiores em uma população de risco cardiovascular mais elevado. Foram incluídos indivíduos consecutivamente submetidos a uma avaliação rotineira de saúde em um único centro e que apresentavam um risco em 10 anos de doença cardiovascular aterosclerótica (DCVAS) ≥ 7,5% ("pooled cohort equations", ACC/AHA, 2013). Para cada indivíduo, foram simuladas duas estratégias baseadas em meta de LDL-c (≤ 100 mg/dL [Emeta-100] ou ≤ 70 mg/dL [Emeta-70]) e duas estratégias baseadas em redução percentual do LDL-c (30% [E30%] ou 50% [E50%]). Em 1.897 indivíduos (57 ± 7 anos, 96% homens, risco em 10 anos de DCVAS 13,7 ± 7,1%), o LDL-c seria reduzido de 141 ± 33 mg/dL para 99 ± 23 mg/dL na E30%, 71 ± 16 mg/dL na E50%, 98 ± 9 mg/dL na Emeta-100 e 70 ± 2 mg/dL na Emeta-70. O risco em 10 anos de DCVAS seria reduzido para 8,8 ± 4,8% na E50% e para 8,9 ± 5,2 na Emeta-70. O número de eventos cardiovasculares maiores prevenidos em 10 anos por 1.000 indivíduos seria de 32 na E30%, 31 na Emeta-100, 49 na E50% e 48 na Emeta-70. Em comparação com a Emeta-70, a E50% evitaria mais eventos no tercil inferior de LDL-c e menos eventos no tercil superior de LDL-c. As abordagens hipolipemiantes mais agressivas simuladas neste estudo, com base em meta de LDL-c ou redução percentual, podem potencialmente prevenir cerca de 50% mais eventos cardiovasculares graves na população em comparação com os tratamentos menos intensivos. Os níveis basais de LDL-c determinam qual estratégia (baseada ou não em meta de LDL-c) é mais apropriada para cada indivíduo.
Waidmann, Oliver; Trojan, Jörg; Friedrich-Rust, Mireen; Sarrazin, Christoph; Bechstein, Wolf Otto; Ulrich, Frank; Zeuzem, Stefan; Albert, Jörg Gerhard
2013-01-01
AIM: To compare clinical success and complications of uncovered self-expanding metal stents (SEMS) vs covered SEMS (cSEMS) in obstruction of the small bowel. METHODS: Technical success, complications and outcome of endoscopic SEMS or cSEMS placement in tumor related obstruction of the duodenum or jejunum were retrospectively assessed. The primary end points were rates of stent migration and overgrowth. Secondary end points were the effect of concomitant biliary drainage on migration rate and overall survival. The data was analyzed according to the Strengthening the Reporting of Observational Studies in Epidemiology guidelines. RESULTS: Thirty-two SEMS were implanted in 20 patients. In all patients, endoscopic stent implantation was successful. Stent migration was observed in 9 of 16 cSEMS (56%) in comparison to 0/16 SEMS (0%) implantations (P = 0.002). Stent overgrowth did not significantly differ between the two stent types (SEMS: 3/16, 19%; cSEMS: 2/16, 13%). One cSEMS dislodged and had to be recovered from the jejunum by way of laparotomy. Time until migration between SEMS and cSEMS in patients with and without concomitant biliary stents did not significantly differ (HR = 1.530, 95%CI 0.731-6.306; P = 0.556). The mean follow-up was 57 ± 71 d (range: 1-275 d). CONCLUSION: SEMS and cSEMS placement is safe in small bowel tumor obstruction. However, cSEMS is accompanied with a high rate of migration in comparison to uncovered SEMS. PMID:24115817
Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi
2017-10-01
Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (<30%) stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).
Pendleton, Michael W; Washburn, Dorothy K; Ellis, E Ann; Pendleton, Bonnie B
2014-03-01
The same sherd was analyzed using a scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and a micro X-ray fluorescence tube attached to a scanning electron microscope (Micro-XRF-SEM) to compare the effectiveness of elemental detection of iron-based pigment. To enhance SEM-EDS mapping, the sherd was carbon coated. The carbon coating was not required to produce Micro-XRF-SEM maps but was applied to maintain an unbiased comparison between the systems. The Micro-XRF-SEM analysis was capable of lower limits of detection than that of the SEM-EDS system, and therefore the Micro-XRF-SEM system could produce elemental maps of elements not easily detected by SEM-EDS mapping systems. Because SEM-EDS and Micro-XRF-SEM have been used for imaging and chemical analysis of biological samples, this comparison of the detection systems should be useful to biologists, especially those involved in bone or tooth (hard tissue) analysis.
Pendleton, Michael W.; Washburn, Dorothy K.; Ellis, E. Ann; Pendleton, Bonnie B.
2014-01-01
The same sherd was analyzed using a scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and a micro X-ray fluorescence tube attached to a scanning electron microscope (Micro-XRF-SEM) to compare the effectiveness of elemental detection of iron-based pigment. To enhance SEM-EDS mapping, the sherd was carbon coated. The carbon coating was not required to produce Micro-XRF-SEM maps but was applied to maintain an unbiased comparison between the systems. The Micro-XRF-SEM analysis was capable of lower limits of detection than that of the SEM-EDS system, and therefore the Micro-XRF-SEM system could produce elemental maps of elements not easily detected by SEM-EDS mapping systems. Because SEM-EDS and Micro-XRF-SEM have been used for imaging and chemical analysis of biological samples, this comparison of the detection systems should be useful to biologists, especially those involved in bone or tooth (hard tissue) analysis. PMID:24600333
Hald, Gert Martin; Stulhofer, Aleksandar; Lange, Theis
2018-03-01
Investigations of patterns of sexual arousal to certain groups of sexually explicit media (SEM) in the general population in non-laboratory settings are rare. Such knowledge could be important to understand more about the relative specificity of sexual arousal in different SEM users. (i) To investigate whether sexual arousal to non-mainstream vs mainstream SEM contents could be categorized across gender and sexual orientation, (ii) to compare levels of SEM-induced sexual arousal, sexual satisfaction, and self-evaluated sexual interests and fantasies between non-mainstream and mainstream SEM groups, and (iii) to explore the validity and predictive accuracy of the Non-Mainstream Pornography Arousal Scale (NPAS). Online cross-sectional survey of 2,035 regular SEM users in Croatia. Patterns of sexual arousal to 27 different SEM themes, sexual satisfaction, and self-evaluations of sexual interests and sexual fantasies. Groups characterized by sexual arousal to non-mainstream SEM could be identified across gender and sexual orientation. These non-mainstream SEM groups reported more SEM use and higher average levels of sexual arousal across the 27 SEM themes assessed compared with mainstream SEM groups. Only few differences were found between non-mainstream and mainstream SEM groups in self-evaluative judgements of sexual interests, sexual fantasies, and sexual satisfaction. The internal validity and predictive accuracy of the NPAS was good across most user groups investigated. The findings suggest that in classified non-mainstream SEM groups, patterns of sexual arousal might be less fixated and category specific than previously assumed. Further, these groups are not more judgmental of their SEM-related sexual arousal patterns than groups characterized by patterns of sexual arousal to more mainstream SEM content. Moreover, accurate identification of non-mainstream SEM group membership is generally possible across gender and sexual orientation using the NPAS. Hald GM, Stulhofer A, Lange T, et al. Sexual Arousal and Sexually Explicit Media (SEM): Comparing Patterns of Sexual Arousal to SEM and Sexual Self-Evaluations and Satisfaction Across Gender and Sexual Orientation. Sex Med 2018;6:30-38. Copyright © 2017. Published by Elsevier Inc.
Modified UMS, Modified SemRep and SemMedDB-UTH | Informatics Technology for Cancer Research (ITCR)
Modified UMLS, modified SemRep and SemMedDB-UTH – these are resources (UMLS, SemMedDB-UT) and tools (SemRep) created and maintained by National Library of Medicine that we have modified for personalized cancer therapy and returned to the NLM.
A Data-Driven Approach to SEM Development at a Two-Year College
ERIC Educational Resources Information Center
Pirius, Landon K.
2014-01-01
This article explores implementation of strategic enrollment management (SEM) at a two-year college and why SEM is critical to the long-term viability of an institution. This article also outlines the five initial steps needed to implement SEM, including identifying SEM leadership, building a SEM committee, developing a common understanding of…
?Cuales son las amenazas o peligros volcanicos?
Myers, Bobbie; Brantley, Steven R.; Stauffer, Peter; Hendley, James W.
2000-01-01
Los volcanes son capaces de producir numerosos peligros geologicos e hidrologicos. Los cientificos del Servicio Geologico de los EE. UU. (USGS, por sus siglas en ingles) y de otras instituciones alrededor del mundo estan estudiando los peligros de muchos de los centenares de volcanes activos y potencialmente activos del mundo. Estos cientificos vigilan muy de cerca la actividad de algunos de los volcanes mas peligrosos, por lo que estan preparados para alertar a las autoridades y/o a la poblacion en caso de que aumente sustancialmente la probabilidad de que ocurra una erupcion u otro evento peligroso.
Ahmed, Abul-Fotouh; Alshahrani, Saad; Morgan, Anthony; Gabr, Ahmed H; Abdel-Razik, Mohamed; Daoud, Abdallah
2017-12-01
To evaluate the frequency of sex-enhancing medications (S-EM) use and to investigate the demographics and sexual characteristics of the S-EM users amongst a Saudi Arabian male population. A cross-sectional sample of 1176 Saudi Arabian men was recruited using a web-based survey between 1 January and 1 April 2015. The survey included multiple open and closed questions to assess the frequency of S-EM use; and demographics, clinical, and sexual characteristics of S-EM users, as well as their perceptions of S-EM. Amongst the participants, 1008 were sexually active and included in the data analysis. Of the sexually active participants, 402 (39.9%) reported S-EM use in the form of herbal or phosphodiesterase type 5 inhibitors at some time in their lives. Comparing S-EM users with S-EM non-users, the S-EM users had a number of demographic and sexual characteristics including: higher education level, higher income, smoking, more than one sexual partner, longer sexual activity duration, higher frequency of sexual intercourse, and lower sexual satisfaction level. Most of the S-EM users (82.1%) bought S-EM without a medical prescription and 62.5% had used them recreationally. In all, 52% of respondents used S-EM to treat ED and 69% of those who used it recreationally reported enhancement of erection with S-EM usage. Demographic and sexual characteristics of S-EM users and the attitude of the users towards the S-EM were identified amongst a Saudi Arabian male population.
Lopatina, Elena; Damani, Zaheed; Bohm, Eric; Noseworthy, Tom W; Conner-Spady, Barbara; MacKean, Gail; Simpson, Chris S; Marshall, Deborah A
2017-09-01
Long waiting times for elective services continue to be a challenging issue. Single-entry models (SEMs) are used to increase access to and flow through the healthcare system. This paper provides a roadmap for healthcare decision-makers, managers, physicians, and researchers to guide implementation and management of successful and sustainable SEMs. The roadmap was informed by an inductive qualitative synthesis of the findings from a deliberative process (a symposium on SEMs, with clinicians, researchers, senior policy-makers, healthcare managers, and patient representatives) and focus groups with the symposium participants. SEMs are a promising strategy to improve the management of referrals and represent one approach to reduce waiting times. The SEMs roadmap outlines current knowledge about SEMs and critical success factors for SEMs' implementation and management. This SEM roadmap is intended to help clinicians, decision-makers, managers, and researchers interested in developing new or strengthening existing SEMs. We consider this roadmap to be a living document that will continue to evolve as we learn more about implementing and managing sustainable SEMs. Copyright © 2017 Elsevier B.V. All rights reserved.
SEM-based overlay measurement between via patterns and buried M1 patterns using high-voltage SEM
NASA Astrophysics Data System (ADS)
Hasumi, Kazuhisa; Inoue, Osamu; Okagawa, Yutaka; Shao, Chuanyu; Leray, Philippe; Halder, Sandip; Lorusso, Gian; Jehoul, Christiane
2017-03-01
The miniaturization of semiconductors continues, importance of overlay measurement is increasing. We measured overlay with analysis SEM called Miracle Eye which can output ultrahigh acceleration voltage in 1998. Meanwhile, since 2006, we have been working on SEM based overlay measurement and developed overlay measurement function of the same layer using CD-SEM. Then, we evaluated overlay of the same layer pattern after etching. This time, in order to measure overlay after lithography, we evaluated the see-through overlay using high voltage SEM CV5000 released in October 2016. In collaboration between imec and Hitachi High-Technologies, we evaluated repeatability, TIS of SEM-OVL as well as correlation between SEM-OVL and Opt-OVL in the M1@ADI and V0@ADI process. Repeatability and TIS results are reasonable and SEM-OVL has good correlation with Opt-OVL. By overlay measurement using CV 5000, we got the following conclusions. (1)SEM_OVL results of both M1 and V0 at ADI show good correlation to OPT_OVL. (2)High voltage SEM can prove the measurement capability of a small pattern(Less than 1 2um) like device that can be placed in-die area. (3)"In-die SEM based overlay" shows possibility for high order control of scanner
Antebi-Gruszka, Nadav; Downing, Martin J.
2016-01-01
The last decade has seen a dramatic increase in the availability of sexually explicit media (SEM) on the Internet. Men who have sex with men (MSM) report near universal use of SEM. However, this widespread use of SEM among MSM may contribute to more condomless anal sex. To examine the association of viewing SEM on the Internet and the number of condomless anal sex encounters among MSM, in 2012, an online survey was conducted of 265 MSM from New York, Philadelphia, Baltimore, or Washington D.C. who reported viewing SEM online in the past 3 months. Analyses were performed using negative binomial regression. Nearly all men reported viewing SEM featuring anal sex with (91%) or without (92%) condoms in the past 3 months. Neither viewing more hours of SEM per week or compulsively viewing SEM were associated with more condomless anal sex encounters. Rather, viewing a greater proportion of SEM containing condomless anal sex was associated with engaging in more condomless anal encounters (IRR = 1.25), while viewing a greater proportion of SEM containing anal sex where condoms were used was associated with fewer condomless anal sex encounters (IRR = 0.62). MSM reported that viewing SEM caused changes in their sexual fantasies, desires, and behaviors. These findings provide important insights for health policy and the design of interventions addressing SEM and condomless sex among MSM. The findings suggest that condom use by SEM performers may benefit not only actor health, but also have health implications for SEM viewers. PMID:27119990
CD-SEM real time bias correction using reference metrology based modeling
NASA Astrophysics Data System (ADS)
Ukraintsev, V.; Banke, W.; Zagorodnev, G.; Archie, C.; Rana, N.; Pavlovsky, V.; Smirnov, V.; Briginas, I.; Katnani, A.; Vaid, A.
2018-03-01
Accuracy of patterning impacts yield, IC performance and technology time to market. Accuracy of patterning relies on optical proximity correction (OPC) models built using CD-SEM inputs and intra die critical dimension (CD) control based on CD-SEM. Sub-nanometer measurement uncertainty (MU) of CD-SEM is required for current technologies. Reported design and process related bias variation of CD-SEM is in the range of several nanometers. Reference metrology and numerical modeling are used to correct SEM. Both methods are slow to be used for real time bias correction. We report on real time CD-SEM bias correction using empirical models based on reference metrology (RM) data. Significant amount of currently untapped information (sidewall angle, corner rounding, etc.) is obtainable from SEM waveforms. Using additional RM information provided for specific technology (design rules, materials, processes) CD extraction algorithms can be pre-built and then used in real time for accurate CD extraction from regular CD-SEM images. The art and challenge of SEM modeling is in finding robust correlation between SEM waveform features and bias of CD-SEM as well as in minimizing RM inputs needed to create accurate (within the design and process space) model. The new approach was applied to improve CD-SEM accuracy of 45 nm GATE and 32 nm MET1 OPC 1D models. In both cases MU of the state of the art CD-SEM has been improved by 3x and reduced to a nanometer level. Similar approach can be applied to 2D (end of line, contours, etc.) and 3D (sidewall angle, corner rounding, etc.) cases.
Estimativa de imagens solares soho através de redes neurais artificiais
NASA Astrophysics Data System (ADS)
Andrade, M. C.; Fernandes, F. C. R.; Cecatto, J. R.; Rios Neto, A.; Rosa, R. R.; Sawant, H. S.
2003-08-01
A Rede Neural Artificial (RNA), no âmbito da teoria computacional, constitui uma teoria emergente que, por possuir habilidade em aprender a partir de dados de entrada, encontra diferentes aplicações em diferentes áreas. Um exemplo é a utilização de RNA na caracterização de padrões associados à dinâmica de processos espaço-temporais relacionados a fenômenos físicos não-lineares. Para obter informações sobre o comportamento destes fenômenos físicos utiliza-se, em diversos casos, seqüências de imagens digitalizadas, onde a caracterização de alguns fenômenos espaço-temporais é o procedimento mais viável para descrever a dinâmica das regiões ativas do Sol. Com base em imagens observadas por telescópios a bordo de satélites, estudos de previsão de eventos solares podem ser programados, permitindo prever possíveis efeitos posteriores nas regiões mais próximas da Terra (tempestades geomagnéticas e irregularidades ionosféricas). Neste trabalho avaliamos o desempenho da RNA para estimar padrões espaço-temporais, ou seja, imagens solares em ultravioleta, obtidas através do telescópio a bordo do satélite SOHO. Os resultados mostraram que as RNA conseguem generalizar os padrões de maneira satisfatória sem perder de forma significativa os principais aspectos da configuração global da atmosfera solar, comprovando a eficácia da RNA como ferramenta para esse tipo de aplicação. Portanto, este trabalho comprova a viabilidade de uso desta ferramenta em projetos voltados ao estudo do comportamento solar, em trabalhos do grupo de Física do Meio Interplanetário (FMI) na DAS e em programas desenvolvidos pelo Núcleo de Simulação e Análise de Sistemas Complexos (NUSASC) do Laboratório Associado de Computação e Matemática Aplicada (LAC) do INPE.
NASA Astrophysics Data System (ADS)
Balan, Catalin
Na ultima decada, foram feitos grandes progressos no desenvolvimento dos detetores de detecao direta das particulas que constituem a materia negra. Com estrategias do aumento gradual do volume do alvo e, simultaneamente, de reducao dos niveis de fundo, a experiencia XENON obteve resultados muito bons e perspetivas promissoras para a detecao de materia negra. Tarefas relativas a analise de dados experimentais adquiridos com o detetor de dupla fase em uso, assim como as simulacoes do campo eletrico, desenvolvimento, montagem e testes para o proximo detetor XENON1T, assim como a participacao regular na manutencao geral e monitorizacao do prototipo atual XENON100 no LNGS, constituiram o plano de trabalhos para as atividades de investigacao do presente doutoramento e a minha contribuicao para a otimizacao da detecao de cintilacao nos detetores da experiencia XENON. A necessidade de alcancar niveis elevados de sensibilidade, requer inovacao em todos os aspetos fisicos do detetor, assim como a reducao de todas as fontes de radioatividade que contribuem para o fundo. O modo mais indicado de operacao para os detetores com enchimento a Xe no estado liquido e gasoso envolve a medicao da cintilacao primaria e da secundaria provenientes da interacao das particulas no Xe liquido. A razao entre estes dois sinais permite diferenciar claramente a maior parte dos eventos correspondentes as fundo dos eventos correspondentes a WIMPs. Deste modo, a leitura dos sinais correspondentes a cintilacao e de extrema importancia. A amplitude do sinal de cintilacao antes dos fotossensores e maximizada atraves da otimizacao de varios parametros, tais como a geometria do alvo do detetor, a transparencia das grelhas dos eletrodos, a uniformidade do ganho em cintilacao secundaria e a utilizacao de material reflectivo para cobrir as superficies que nao sao fotossensiveis.
Endoscopic removal of malfunctioning biliary self-expandable metallic stents.
Familiari, Pietro; Bulajic, Milutin; Mutignani, Massimiliano; Lee, Linda S; Spera, Gianluca; Spada, Cristiano; Tringali, Andrea; Costamagna, Guido
2005-12-01
Endoscopic removal of malfunctioning self-expandable metallic biliary stents (SEMS) is difficult and not well described. The aim of this study is to review the indications, the techniques, and the results of SEMS removal in a cohort of patients with malfunctioning stents. All patients who underwent an attempt at endoscopic removal of biliary SEMS over a 5-year period were retrospectively identified. The main indications for SEMS removal were the following: distal migration of the stent or impaction to the duodenum, impaction into the bile-duct wall, tissue ingrowth, and inappropriate length of the stent causing occlusion of intrahepatic ducts. SEMS were removed by using foreign-body forceps or polypectomy snares. Endoscopic removal of 39 SEMS (13 uncovered and 26 covered) was attempted in 29 patients (17 men; mean age, 66 years). SEMS extraction was attempted after a mean of 7.5 months (8.75 months standard deviation) post-SEMS insertion. Removal was successful in 20 patients (68.9%) and in 29 SEMS (74.3%). Covered SEMS were effectively removed more frequently than uncovered ones: 24 of 26 (92.3%) and 5 of 13 (38.4%), respectively (p < 0.05). No major complications were recorded. Multivariate analysis showed that the time interval between insertion and removal, SEMS length, stent-mesh design (zigzag vs. interlaced), and indication for removal were not predictive of success at stent removal. Endoscopic removal of biliary SEMS is feasible and safe in more than 70% of cases. Because only 38% of uncovered SEMS were removable, the presence of a stent covering is the only factor predictive of successful stent extraction. The presence of diffuse and severe ingrowth was the main feature limiting SEMS removal.
The effects of sexually explicit material use on romantic relationship dynamics
Minarcik, Jenny; Wetterneck, Chad T.; Short, MARY B.
2016-01-01
Background and aims Pornography use has become increasingly common. Studies have shown that individuals who use sexually explicit materials (SEMs) report negative effects (Schneider, 2000b). However, Bridges (2008b) found that couples who use SEM together have higher relationship satisfaction than those who use SEM independently. A further investigation into various types of SEM use in relationships may highlight how SEM is related to various areas of couple satisfaction. Thus, the purpose of the current study is to examine the impact of SEM use related to different relationship dynamics. Methods The current study included a college and Internet sample of 296 participants divided into groups based upon the SEM use in relationships (i.e., SEM alone, SEM use with partner, and no SEM use). Results There were significant differences between groups in relationship satisfaction [F(2, 252) = 3.69, p = .026], intimacy [F(2, 252) = 7.95, p = <.001], and commitment [F(2, 252) = 5.30, p = .006]. Post-hoc analyses revealed additional differences in relationship satisfaction [t(174) = 2.13, p = .035] and intimacy [t(174) = 2.76, p = .006] based on the frequency of SEM use. Discussion Further exploration of the SEM use function in couples will provide greater understanding of its role in romantic relationships. PMID:27784182
Scanning Electron Microscope-Cathodoluminescence Analysis of Rare-Earth Elements in Magnets.
Imashuku, Susumu; Wagatsuma, Kazuaki; Kawai, Jun
2016-02-01
Scanning electron microscope-cathodoluminescence (SEM-CL) analysis was performed for neodymium-iron-boron (NdFeB) and samarium-cobalt (Sm-Co) magnets to analyze the rare-earth elements present in the magnets. We examined the advantages of SEM-CL analysis over conventional analytical methods such as SEM-energy-dispersive X-ray (EDX) spectroscopy and SEM-wavelength-dispersive X-ray (WDX) spectroscopy for elemental analysis of rare-earth elements in NdFeB magnets. Luminescence spectra of chloride compounds of elements in the magnets were measured by the SEM-CL method. Chloride compounds were obtained by the dropwise addition of hydrochloric acid on the magnets followed by drying in vacuum. Neodymium, praseodymium, terbium, and dysprosium were separately detected in the NdFeB magnets, and samarium was detected in the Sm-Co magnet by the SEM-CL method. In contrast, it was difficult to distinguish terbium and dysprosium in the NdFeB magnet with a dysprosium concentration of 1.05 wt% by conventional SEM-EDX analysis. Terbium with a concentration of 0.02 wt% in an NdFeB magnet was detected by SEM-CL analysis, but not by conventional SEM-WDX analysis. SEM-CL analysis is advantageous over conventional SEM-EDX and SEM-WDX analyses for detecting trace rare-earth elements in NdFeB magnets, particularly dysprosium and terbium.
1989-07-07
Colonel H. Dale Brown, Jr., De mahder for Administration/Prept-o-r, Martin Army Community HQz12ita1_-FortT-Benning, Georgia 31905-6100 FOR Chairman...Peyton 5 Review of the Literature Evento Leading to the Development of PRIMUS The Department of Defense Authorization Act of 1984 directed that DoD...direction for providing M. Peyton 11 increased access to primary care. While a great deal of thought and planning was put forth in developing the
Using digital colour to increase the realistic appearance of SEM micrographs of bloodstains.
Hortolà, Policarp
2010-10-01
Although in the scientific-research literature the micrographs from scanning electron microscopes (SEMs) are usually displayed in greyscale, the potential of colour resources provided by the SEM-coupled image-acquiring systems and, subsidiarily, by image-manipulation free softwares deserves be explored as a tool for colouring SEM micrographs of bloodstains. After acquiring greyscale SEM micrographs of a (dark red to the naked eye) human blood smear on grey chert, they were manually obtained in red tone using both the SEM-coupled image-acquiring system and an image-manipulation free software, as well as they were automatically generated in thermal tone using the SEM-coupled system. Red images obtained by the SEM-coupled system demonstrated lower visual-discrimination capability than the other coloured images, whereas those in red generated by the free software rendered better magnitude of scopic information than the red images generated by the SEM-coupled system. Thermal-tone images, although were further from the real sample colour than the red ones, not only increased their realistic appearance over the greyscale images, but also yielded the best visual-discrimination capability among all the coloured SEM micrographs, and fairly enhanced the relief effect of the SEM micrographs over both the greyscale and the red images. The application of digital colour by means of the facilities provided by an SEM-coupled image-acquiring system or, when required, by an image-manipulation free software provides a user-friendly, quick and inexpensive way of obtaining coloured SEM micrographs of bloodstains, avoiding to do sophisticated, time-consuming colouring procedures. Although this work was focused on bloodstains, well probably other monochromatic or quasi-monochromatic samples are also susceptible of increasing their realistic appearance by colouring them using the simple methods utilized in this study.
Budzyńska, Agnieszka; Nowakowska-Duława, Ewa; Marek, Tomasz; Hartleb, Marek
2016-10-01
Most patients with malignant biliary obstruction are suited only for palliation by endoscopic drainage with plastic stents (PS) or self-expandable metal stents (SEMS). To compare the clinical outcome and costs of biliary stenting with SEMS and PS in patients with malignant biliary strictures. A total of 114 patients with malignant jaundice who underwent 376 endoscopic retrograde biliary drainage (ERBD) were studied. ERBD with the placement of PS was performed in 80 patients, with one-step SEMS in 20 patients and two-step SEMS in 14 patients. Significantly fewer ERBD interventions were performed in patients with one-step SEMS than PS or the two-step SEMS technique (2.0±1.12 vs. 3.1±1.7 or 5.7±2.1, respectively, P<0.0001). The median hospitalization duration per procedure was similar for the three groups of patients. The patients' survival time was the longest in the two-step SEMS group in comparison with the one-step SEMS and PS groups (596±270 vs. 276±141 or 208±219 days, P<0.001). Overall median time to recurrent biliary obstruction was 89.3±159 days for PS and 120.6±101 days for SEMS (P=0.01). The total cost of hospitalization with ERBD was higher for two-step SEMS than for one-step SEMS or PS (1448±312, 1152±135 and 977±156&OV0556;, P<0.0001). However, the estimated annual cost of medical care for one-step SEMS was higher than that for the two-step SEMS or PS groups (4618, 4079, and 3995&OV0556;, respectively). Biliary decompression by SEMS is associated with longer patency and reduced number of auxiliary procedures; however, repeated PS insertions still remain the most cost-effective strategy.
EPA Region 2 SEMS_CERCLIS Sites All [R2] and SEMS_CERCLIS Sites NPL [R2] GIS Layers
The Region 2 SEMS_CERCLIS Sites All [R2] GIS layer contains unique Superfund Enterprise Management System (SEMS) site records. These records have the following NPL_STATUS designations: CURRENTLY ON FINAL NPL, DELETED FROM FINAL NPL, NOT ON NPL, PROPOSED FOR NPL, REMOVED FROM PROPOSED NPL, and SITE IS PART OF NPL SITE. The Region 2 SEMS_CERCLIS NPL Sites [R2] GIS layer only has SEMS records with the following NPL_STATUS designations: 'CURRENTLY ON FINAL NPL', 'DELETED FROM FINAL NPL', 'PROPOSED FOR NPL'.The Superfund Enterprise Management System (SEMS) is EPA's official record for tracking hazardous waste sites, potentially hazardous waste sites, and remedial activities performed in support of the Superfund Program across the nation. This includes sites that are on the National Priorities List (NPL) or are being considered for the NPL. SEMS represents a joint development and ongoing collaboration between Superfund's Remedial, Removal, Federal Facilities, Enforcement, and Emergency Response programs. It provides its wide audience base with a means of ongoing analysis of Superfund Program activities and informational needs at the site, regional management, and national management levels. The customers of SEMS or SEMS data are five EPA Headquarters offices and regional staff, citizens, the regulated community, other Federal agencies, States, Tribes, local agencies, and industry. SEMS stakeholders are States, Congress, other Federal agencies, industry groups, and cit
Simulation of FIB-SEM images for analysis of porous microstructures.
Prill, Torben; Schladitz, Katja
2013-01-01
Focused ion beam nanotomography-scanning electron microscopy tomography yields high-quality three-dimensional images of materials microstructures at the nanometer scale combining serial sectioning using a focused ion beam with SEM. However, FIB-SEM tomography of highly porous media leads to shine-through artifacts preventing automatic segmentation of the solid component. We simulate the SEM process in order to generate synthetic FIB-SEM image data for developing and validating segmentation methods. Monte-Carlo techniques yield accurate results, but are too slow for the simulation of FIB-SEM tomography requiring hundreds of SEM images for one dataset alone. Nevertheless, a quasi-analytic description of the specimen and various acceleration techniques, including a track compression algorithm and an acceleration for the simulation of secondary electrons, cut down the computing time by orders of magnitude, allowing for the first time to simulate FIB-SEM tomography. © Wiley Periodicals, Inc.
Structural equation modeling in pediatric psychology: overview and review of applications.
Nelson, Timothy D; Aylward, Brandon S; Steele, Ric G
2008-08-01
To describe the use of structural equation modeling (SEM) in the Journal of Pediatric Psychology (JPP) and to discuss the usefulness of SEM applications in pediatric psychology research. The use of SEM in JPP between 1997 and 2006 was examined and compared to leading journals in clinical psychology, clinical child psychology, and child development. SEM techniques were used in <4% of the empirical articles appearing in JPP between 1997 and 2006. SEM was used less frequently in JPP than in other clinically relevant journals over the past 10 years. However, results indicated a recent increase in JPP studies employing SEM techniques. SEM is an under-utilized class of techniques within pediatric psychology research, although investigations employing these methods are becoming more prevalent. Despite its infrequent use to date, SEM is a potentially useful tool for advancing pediatric psychology research with a number of advantages over traditional statistical methods.
The Effects of Gay Sexually Explicit Media on the HIV Risk Behavior of Men who have Sex with Men
Simon Rosser, B. R.; Smolenski, Derek J.; Erickson, Darin; Iantaffi, Alex; Brady, Sonya S.; Galos, Dylan L.; Grey, Jeremy A.; Hald, Gert Martin; Horvath, Keith J.; Kilian, Gunna; Træen, Bente; Wilkerson, J. Michael
2013-01-01
This study sought to study consumption patterns of gay-oriented sexually explicit media (SEM) by men who have sex with men (MSM); and to investigate a hypothesized relationship between gay SEM consumption and HIV risk behavior. Participants were 1391 MSM living in the US, recruited online to complete a SEM consumption and sexual risk survey. Almost all (98.5%) reported some gay SEM exposure over the last 90 days. While 41% reported a preference to watch actors perform anal sex without condoms (termed “bareback SEM”), 17% preferred to actors perform anal sex with condoms (termed “safer sex SEM”) and 42% reported no preference. Overall SEM consumption was not associated with HIV risk; however participants who watched more bareback SEM reported significantly greater odds of engaging in risk behavior. The results suggest that a preference for bareback SEM is associated with engaging in risk behavior. More research to understand how MSM develop and maintain preferences in viewing SEM, and to identify new ways to use SEM in HIV prevention, is recommended. PMID:23564010
Weber, Kathryn; Delben, Juliana; Bromage, Timothy G; Duarte, Simone
2014-01-01
The study compared images of mature Streptococcus mutans biofilms captured at increasing magnification to determine which microscopy method is most acceptable for imaging the biofilm topography and the extracellular polymeric substance (EPS). In vitro S. mutans biofilms were imaged using (1) scanning electron microscopy (SEM), which requires a dehydration process; (2) SEM and ruthenium red (SEM-RR), which has been shown to support the EPS of biofilms during the SEM dehydration; and (3) variable pressure scanning electron microscopy (VPSEM), which does not require the intensive dehydration process of SEM. The dehydration process and high chamber vacuum of both SEM techniques devastated the biofilm EPS, removed supporting structures, and caused cracking on the biofilm surface. The VPSEM offered the most comprehensive representation of the S. mutans biofilm morphology. VPSEM provides similar contrast and focus as the SEM, but the procedure is far less time-consuming, and the use of hazardous chemicals associated with SEM dehydration protocol is avoided with the VPSEM. The inaccurate representations of the biofilm EPS in SEM experimentation is a possible source of inaccurate data and impediments in the study of S. mutans biofilms. © 2013 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.
Long-term outcome of self expandable metal stents for biliary obstruction in chronic pancreatitis.
Waldthaler, Alexander; Schütte, Kerstin; Weigt, Jochen; Kropf, Siegfried; Malfertheiner, Peter; Kahl, Stefan
2013-01-10
Insertion of a self-expandable metal stent is still controversial for treatment of benign common bile duct stenosis but can be a valuable alternative to surgical treatment. Aim of our study was to analyze the efficacy of covered and uncovered self-expandable metal stent in patients with chronic pancreatitis and common bile duct stenosis. Twenty patients with common bile duct stenosis due to alcoholic chronic pancreatitis were retrospective analyzed. All patients had advanced chronic pancreatitis, presenting with calcifications in pancreatic head. Uncovered self-expandable metal stent (uSEMS) were used in 11 patients (3 females, 8 males) while in 9 patients (3 females, 6 males) partially covered self-expandable metal stent (cSEMS) were inserted. All patients treated with self-expandable metal stent had contraindications for surgery. Overall mean follow up time was 155 weeks: 206 (52-412) weeks in uSEMS, and 93 (25-233) weeks in cSEMS, respectively. Stent patency was in mean 118 weeks: 159 (44-412) weeks in uSEMS and 67 (25-150) weeks in cSEMS (P=0.019). In the uSEMS group, reintervention was necessary in 5 patients (45%) due to stent obstruction, whereas in the cSEMS group 4 patients (44%) needed reintervention (2 obstructions, 2 migration). Stent migration is an early complication, compared to obstruction (P<0.05), and in cSEMS obstruction occurred significantly earlier compared to uSEMS (P<0.05). Patency of uSEMS was significantly longer compared to partially cSEMS. Available self-expandable metal stent, unfortunately, do not meet the demands on successful treatment of benign common bile duct stenosis.
Wullschleger, Marcel; Aghlmandi, Soheila; Egger, Marcel; Zwahlen, Marcel
2014-01-01
In biomedical journals authors sometimes use the standard error of the mean (SEM) for data description, which has been called inappropriate or incorrect. To assess the frequency of incorrect use of SEM in articles in three selected cardiovascular journals. All original journal articles published in 2012 in Cardiovascular Research, Circulation: Heart Failure and Circulation Research were assessed by two assessors for inappropriate use of SEM when providing descriptive information of empirical data. We also assessed whether the authors state in the methods section that the SEM will be used for data description. Of 441 articles included in this survey, 64% (282 articles) contained at least one instance of incorrect use of the SEM, with two journals having a prevalence above 70% and "Circulation: Heart Failure" having the lowest value (27%). In 81% of articles with incorrect use of SEM, the authors had explicitly stated that they use the SEM for data description and in 89% SEM bars were also used instead of 95% confidence intervals. Basic science studies had a 7.4-fold higher level of inappropriate SEM use (74%) than clinical studies (10%). The selection of the three cardiovascular journals was based on a subjective initial impression of observing inappropriate SEM use. The observed results are not representative for all cardiovascular journals. In three selected cardiovascular journals we found a high level of inappropriate SEM use and explicit methods statements to use it for data description, especially in basic science studies. To improve on this situation, these and other journals should provide clear instructions to authors on how to report descriptive information of empirical data.
Hamada, Tsuyoshi; Nakai, Yousuke; Isayama, Hiroyuki; Togawa, Osamu; Kogure, Hirofumi; Kawakubo, Kazumichi; Tsujino, Takeshi; Sasahira, Naoki; Hirano, Kenji; Yamamoto, Natsuyo; Ito, Yukiko; Sasaki, Takashi; Mizuno, Suguru; Toda, Nobuo; Tada, Minoru; Koike, Kazuhiko
2014-03-01
Self-expandable metallic stent (SEMS) placement is widely carried out for distal malignant biliary obstruction, and survival analysis is used to evaluate the cumulative incidences of SEMS dysfunction (e.g. the Kaplan-Meier [KM] method and the log-rank test). However, these statistical methods might be inappropriate in the presence of 'competing risks' (here, death without SEMS dysfunction), which affects the probability of experiencing the event of interest (SEMS dysfunction); that is, SEMS dysfunction can no longer be observed after death. A competing risk analysis has rarely been done in studies on SEMS. We introduced the concept of a competing risk analysis and illustrated its impact on the evaluation of SEMS outcomes using hypothetical and actual data. Our illustrative study included 476 consecutive patients who underwent SEMS placement for unresectable distal malignant biliary obstruction. A significant difference between cumulative incidences of SEMS dysfunction in male and female patients via theKM method (P = 0.044 by the log-rank test) disappeared after applying a competing risk analysis (P = 0.115 by Gray's test). In contrast, although cumulative incidences of SEMS dysfunction via the KM method were similar with and without chemotherapy (P = 0.647 by the log-rank test), cumulative incidence of SEMS dysfunction in the non-chemotherapy group was shown to be significantly lower (P = 0.031 by Gray's test) in a competing risk analysis. Death as a competing risk event needs to be appropriately considered in estimating a cumulative incidence of SEMS dysfunction, otherwise analytical results may be biased. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Sonomura, Takahiro; Furuta, Takahiro; Nakatani, Ikuko; Yamamoto, Yo; Honma, Satoru; Kaneko, Takeshi
2014-11-01
Ten years have passed since a serial block-face scanning electron microscopy (SBF-SEM) method was developed [1]. In this innovative method, samples were automatically sectioned with an ultramicrotome placed inside a scanning electron microscope column, and the block surfaces were imaged one after another by SEM to capture back-scattered electrons. The contrast-inverted images obtained by the SBF-SEM were very similar to those acquired using conventional TEM. SFB-SEM has made easy to acquire image stacks of the transmission electron microscopy (TEM) in the mesoscale, which is taken with the confocal laser-scanning microcopy(CF-LSM).Furthermore, serial-section SEM has been combined with the focused ion beam (FIB) milling method [2]. FIB-incorporated SEM (FIB-SEM) has enabled the acquisition of three-dimensional images with a higher z-axis resolution com- pared to ultramicrotome-equipped SEM.We tried immunocytochemistry for FIB-SEM and correlated this immunoreactivity with that in CF-LSM. Dendrites of neurons in the rat neostriatum were visualized using a recombinant viral vector. Moreover, the thalamostriatal afferent terminals were immunolabeled with Cy5 fluorescence for vesicular glutamate transporter 2 (VGluT2). After detection of the sites of terminals apposed to the dendrites by using CF-LSM, GFP and VGluT2 immunoreactivities were further developed for EM by using immunogold/silver enhancement and immunoperoxidase/diaminobenzidine (DAB) methods, respectively.We showed that conventional immuno-cytochemical staining for TEM was applicable to FIB-SEM. Furthermore, several synaptic contacts, which were thought to exist on the basis of CF-LSM findings, were confirmed with FIB-SEM, revealing the usefulness of the combined method of CF-LSM and FIB-SEM. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Virtual Levels and Role Models: N-Level Structural Equations Model of Reciprocal Ratings Data.
Mehta, Paras D
2018-01-01
A general latent variable modeling framework called n-Level Structural Equations Modeling (NL-SEM) for dependent data-structures is introduced. NL-SEM is applicable to a wide range of complex multilevel data-structures (e.g., cross-classified, switching membership, etc.). Reciprocal dyadic ratings obtained in round-robin design involve complex set of dependencies that cannot be modeled within Multilevel Modeling (MLM) or Structural Equations Modeling (SEM) frameworks. The Social Relations Model (SRM) for round robin data is used as an example to illustrate key aspects of the NL-SEM framework. NL-SEM introduces novel constructs such as 'virtual levels' that allows a natural specification of latent variable SRMs. An empirical application of an explanatory SRM for personality using xxM, a software package implementing NL-SEM is presented. Results show that person perceptions are an integral aspect of personality. Methodological implications of NL-SEM for the analyses of an emerging class of contextual- and relational-SEMs are discussed.
Chai, Minwei; Shen, Xiaoxue; Li, Ruili; Qiu, Guoyu
2015-08-15
The risks of heavy metal in Futian mangrove forest sediment were assessed using the acid-volatile sulfide (AVS) and simultaneously extracted metals (SEM) methods. The results indicated that AVS distributions were more variable than the SEM distributions at all 16 sampling sites. The positive correlation between AVS and SEM indicated that their similar formative and existing conditions and that AVS acted as an important carrier for SEM. The major SEM component was Zn (69.7.3-94.2%), whereas the Cd contribution (the most toxic metal present) to SEM was no more than 1%. The possible adverse effects caused by heavy metals at ten sampling sites may be due to higher levels of SEMs, rather than AVSs. The total organic carbon (TOC) was an important metal-binding phase in the sediments. Taking into account the TOC concentration, there were no adverse effects due to heavy metals in any of the Futian mangrove forest sediments. Copyright © 2015 Elsevier Ltd. All rights reserved.
Standard deviation and standard error of the mean.
Lee, Dong Kyu; In, Junyong; Lee, Sangseok
2015-06-01
In most clinical and experimental studies, the standard deviation (SD) and the estimated standard error of the mean (SEM) are used to present the characteristics of sample data and to explain statistical analysis results. However, some authors occasionally muddle the distinctive usage between the SD and SEM in medical literature. Because the process of calculating the SD and SEM includes different statistical inferences, each of them has its own meaning. SD is the dispersion of data in a normal distribution. In other words, SD indicates how accurately the mean represents sample data. However the meaning of SEM includes statistical inference based on the sampling distribution. SEM is the SD of the theoretical distribution of the sample means (the sampling distribution). While either SD or SEM can be applied to describe data and statistical results, one should be aware of reasonable methods with which to use SD and SEM. We aim to elucidate the distinctions between SD and SEM and to provide proper usage guidelines for both, which summarize data and describe statistical results.
Standard deviation and standard error of the mean
In, Junyong; Lee, Sangseok
2015-01-01
In most clinical and experimental studies, the standard deviation (SD) and the estimated standard error of the mean (SEM) are used to present the characteristics of sample data and to explain statistical analysis results. However, some authors occasionally muddle the distinctive usage between the SD and SEM in medical literature. Because the process of calculating the SD and SEM includes different statistical inferences, each of them has its own meaning. SD is the dispersion of data in a normal distribution. In other words, SD indicates how accurately the mean represents sample data. However the meaning of SEM includes statistical inference based on the sampling distribution. SEM is the SD of the theoretical distribution of the sample means (the sampling distribution). While either SD or SEM can be applied to describe data and statistical results, one should be aware of reasonable methods with which to use SD and SEM. We aim to elucidate the distinctions between SD and SEM and to provide proper usage guidelines for both, which summarize data and describe statistical results. PMID:26045923
Hein, L R O; Campos, K A; Caltabiano, P C R O; Kostov, K G
2013-01-01
The methodology for fracture analysis of polymeric composites with scanning electron microscopes (SEM) is still under discussion. Many authors prefer to use sputter coating with a conductive material instead of applying low-voltage (LV) or variable-pressure (VP) methods, which preserves the original surfaces. The present work examines the effects of sputter coating with 25 nm of gold on the topography of carbon-epoxy composites fracture surfaces, using an atomic force microscope. Also, the influence of SEM imaging parameters on fractal measurements is evaluated for the VP-SEM and LV-SEM methods. It was observed that topographic measurements were not significantly affected by the gold coating at tested scale. Moreover, changes on SEM setup leads to nonlinear outcome on texture parameters, such as fractal dimension and entropy values. For VP-SEM or LV-SEM, fractal dimension and entropy values did not present any evident relation with image quality parameters, but the resolution must be optimized with imaging setup, accompanied by charge neutralization. © Wiley Periodicals, Inc.
Viewing Sexually-Explicit Materials Alone or Together: Associations with Relationship Quality
Maddox, Amanda M.; Rhoades, Galena K.; Markman, Howard J.
2010-01-01
This study investigated associations between viewing sexually-explicit material (SEM) and relationship functioning in a random sample of 1291 unmarried individuals in romantic relationships. More men (76.8%) than women (31.6%) reported that they viewed SEM on their own, but nearly half of both men and women reported sometimes viewing SEM with their partner (44.8%). Measures of communication, relationship adjustment, commitment, sexual satisfaction, and infidelity were examined. Individuals who never viewed SEM reported higher relationship quality on all indices than those who viewed SEM alone. Those who viewed SEM only with their partners reported more dedication and higher sexual satisfaction than those who viewed SEM alone. The only difference between those who never viewed SEM and those who viewed it only with their partners was that those who never viewed it had lower rates of infidelity. Implications for future research in this area as well as for sex therapy and couple therapy are discussed. PMID:20039112
Shen, Qinfang; Shi, Herong; Tian, Chenxi; Ghai, Vikas; Liu, Jun
2017-09-01
Proper development of a multicellular organism relies on well-coordinated regulation of cell fate specification, cell proliferation and cell differentiation. The C. elegans postembryonic mesoderm provides a useful system for uncovering factors involved in these processes and for further dissecting their regulatory relationships. The single Spalt-like zinc finger containing protein SEM-4/SALL is known to be involved in specifying the proliferative sex myoblast (SM) fate. We have found that SEM-4/SALL is sufficient to promote the SM fate and that it does so in a cell autonomous manner. We further showed that SEM-4/SALL acts through the SoxC transcription factor SEM-2 to promote the SM fate. SEM-2 is known to promote the SM fate by inhibiting the expression of two BWM-specifying transcription factors. In light of recent findings in mammals showing that Sall4, one of the mammalian homologs of SEM-4, contributes to pluripotency regulation by inhibiting differentiation, our work suggests that the function of SEM-4/SALL proteins in regulating pluripotency versus differentiation appears to be evolutionarily conserved. Copyright © 2017 Elsevier Inc. All rights reserved.
Tarka, Piotr
2018-01-01
This paper is a tribute to researchers who have significantly contributed to improving and advancing structural equation modeling (SEM). It is, therefore, a brief overview of SEM and presents its beginnings, historical development, its usefulness in the social sciences and the statistical and philosophical (theoretical) controversies which have often appeared in the literature pertaining to SEM. Having described the essence of SEM in the context of causal analysis, the author discusses the years of the development of structural modeling as the consequence of many researchers' systematically growing needs (in particular in the social sciences) who strove to effectively understand the structure and interactions of latent phenomena. The early beginnings of SEM models were related to the work of Spearman and Wright, and to that of other prominent researchers who contributed to SEM development. The importance and predominance of theoretical assumptions over technical issues for the successful construction of SEM models are also described. Then, controversies regarding the use of SEM in the social sciences are presented. Finally, the opportunities and threats of this type of analytical strategy as well as selected areas of SEM applications in the social sciences are discussed.
Pornography, sexual socialization, and satisfaction among young men.
Stulhofer, Aleksandar; Busko, Vesna; Landripet, Ivan
2010-02-01
In spite of a growing presence of pornography in contemporary life, little is known about its potential effects on young people's sexual socialization and sexual satisfaction. In this article, we present a theoretical model of the effects of sexually explicit materials (SEM) mediated by sexual scripting and moderated by the type of SEM used. An on-line survey dataset that included 650 young Croatian men aged 18-25 years was used to explore empirically the model. Descriptive findings pointed to significant differences between mainstream and paraphilic SEM users in frequency of SEM use at the age of 14, current SEM use, frequency of masturbation, sexual boredom, acceptance of sex myths, and sexual compulsiveness. In testing the model, a novel instrument was used, the Sexual Scripts Overlap Scale, designed to measure the influence of SEM on sexual socialization. Structural equation analyses suggested that negative effects of early exposure to SEM on young men's sexual satisfaction, albeit small, could be stronger than positive effects. Both positive and negative effects-the latter being expressed through suppression of intimacy-were observed only among users of paraphilic SEM. No effect of early exposure to SEM was found among the mainstream SEM users. To counterbalance moral panic but also glamorization of pornography, sex education programs should incorporate contents that would increase media literacy and assist young people in critical interpretation of pornographic imagery.
Structural Equation Model Trees
ERIC Educational Resources Information Center
Brandmaier, Andreas M.; von Oertzen, Timo; McArdle, John J.; Lindenberger, Ulman
2013-01-01
In the behavioral and social sciences, structural equation models (SEMs) have become widely accepted as a modeling tool for the relation between latent and observed variables. SEMs can be seen as a unification of several multivariate analysis techniques. SEM Trees combine the strengths of SEMs and the decision tree paradigm by building tree…
USDA-ARS?s Scientific Manuscript database
Recent developments in spectrally encoded microspheres (SEMs)-based technologies provide high multiplexing possibilities. Most SEMs-based assays required a flow cytometer with sophisticated fluidics and optics. The new imaging superparamagnetic SEMs-based platform transports SEMs with considerably ...
Multiple-Group Analysis Using the sem Package in the R System
ERIC Educational Resources Information Center
Evermann, Joerg
2010-01-01
Multiple-group analysis in covariance-based structural equation modeling (SEM) is an important technique to ensure the invariance of latent construct measurements and the validity of theoretical models across different subpopulations. However, not all SEM software packages provide multiple-group analysis capabilities. The sem package for the R…
Application of SEM and EDX in studying biomineralization in plant tissues.
He, Honghua; Kirilak, Yaowanuj
2014-01-01
This chapter describes protocols using formalin-acetic acid-alcohol (FAA) to fix plant tissues for studying biomineralization by means of scanning electron microscopy (SEM) and qualitative energy-dispersive X-ray microanalysis (EDX). Specimen preparation protocols for SEM and EDX mainly include fixation, dehydration, critical point drying (CPD), mounting, and coating. Gold-coated specimens are used for SEM imaging, while gold- and carbon-coated specimens are prepared for qualitative X-ray microanalyses separately to obtain complementary information on the elemental compositions of biominerals. During the specimen preparation procedure for SEM, some biominerals may be dislodged or scattered, making it difficult to determine their accurate locations, and light microscopy is used to complement SEM studies. Specimen preparation protocols for light microscopy generally include fixation, dehydration, infiltration and embedding with resin, microtome sectioning, and staining. In addition, microwave processing methods are adopted here to speed up the specimen preparation process for both SEM and light microscopy.
The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.
Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C
2014-01-01
Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.
Galos, Dylan L.; Smolenski, Derek J.; Grey, Jeremy A.; Iantaffi, Alex; Rosser, B.R. Simon
2014-01-01
Sexually explicit media (SEM) is viewed by many men who have sex with men (MSM) and is widely available via the Internet. Though research has investigated the link between SEM and sexual risk behaviour, little has been published about preferences for characteristics of SEM. In an Internet-based cross-sectional study, 1390 adult MSM completed an online survey about their preferences for nine characteristics of SEM and ranked them in order of importance. Respondents preferred free, Internet-based, anonymous SEM portraying behaviours they would do. Cost and looks were the most important characteristics of SEM to participants, while condom use and sexual behaviours themselves were least important. Results suggest that while participants may have preferences for specific behaviours and condom use, these are not the most salient characteristics of SEM to consumers when choosing. PMID:26085898
In Search of Search Engine Marketing Strategy Amongst SME's in Ireland
NASA Astrophysics Data System (ADS)
Barry, Chris; Charleton, Debbie
Researchers have identified the Web as a searchers first port of call for locating information. Search Engine Marketing (SEM) strategies have been noted as a key consideration when developing, maintaining and managing Websites. A study presented here of SEM practices of Irish small to medium enterprises (SMEs) reveals they plan to spend more resources on SEM in the future. Most firms utilize an informal SEM strategy, where Website optimization is perceived most effective in attracting traffic. Respondents cite the use of ‘keywords in title and description tags’ as the most used SEM technique, followed by the use of ‘keywords throughout the whole Website’; while ‘Pay for Placement’ was most widely used Paid Search technique. In concurrence with the literature, measuring SEM performance remains a significant challenge with many firms unsure if they measure it effectively. An encouraging finding is that Irish SMEs adopt a positive ethical posture when undertaking SEM.
The development of comparative bias index
NASA Astrophysics Data System (ADS)
Aimran, Ahmad Nazim; Ahmad, Sabri; Afthanorhan, Asyraf; Awang, Zainudin
2017-08-01
Structural Equation Modeling (SEM) is a second generation statistical analysis techniques developed for analyzing the inter-relationships among multiple variables in a model simultaneously. There are two most common used methods in SEM namely Covariance-Based Structural Equation Modeling (CB-SEM) and Partial Least Square Path Modeling (PLS-PM). There have been continuous debates among researchers in the use of PLS-PM over CB-SEM. While there is few studies were conducted to test the performance of CB-SEM and PLS-PM bias in estimating simulation data. This study intends to patch this problem by a) developing the Comparative Bias Index and b) testing the performance of CB-SEM and PLS-PM using developed index. Based on balanced experimental design, two multivariate normal simulation data with of distinct specifications of size 50, 100, 200 and 500 are generated and analyzed using CB-SEM and PLS-PM.
30 CFR 250.1901 - What is the goal of my SEMS program?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 250.1901 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT... and Environmental Management Systems (SEMS) § 250.1901 What is the goal of my SEMS program? The goal... your SEMS program must be trained to have the skills and knowledge to perform their assigned duties. ...
ERIC Educational Resources Information Center
Beretvas, S. Natasha; Furlow, Carolyn F.
2006-01-01
Meta-analytic structural equation modeling (MA-SEM) is increasingly being used to assess model-fit for variables' interrelations synthesized across studies. MA-SEM researchers have analyzed synthesized correlation matrices using structural equation modeling (SEM) estimation that is designed for covariance matrices. This can produce incorrect…
Tondare, Vipin N; Villarrubia, John S; Vlada R, András E
2017-10-01
Three-dimensional (3D) reconstruction of a sample surface from scanning electron microscope (SEM) images taken at two perspectives has been known for decades. Nowadays, there exist several commercially available stereophotogrammetry software packages. For testing these software packages, in this study we used Monte Carlo simulated SEM images of virtual samples. A virtual sample is a model in a computer, and its true dimensions are known exactly, which is impossible for real SEM samples due to measurement uncertainty. The simulated SEM images can be used for algorithm testing, development, and validation. We tested two stereophotogrammetry software packages and compared their reconstructed 3D models with the known geometry of the virtual samples used to create the simulated SEM images. Both packages performed relatively well with simulated SEM images of a sample with a rough surface. However, in a sample containing nearly uniform and therefore low-contrast zones, the height reconstruction error was ≈46%. The present stereophotogrammetry software packages need further improvement before they can be used reliably with SEM images with uniform zones.
Honda, Shogo; Kohama, Takeshi; Tanaka, Tatsuro; Yoshida, Hisashi
2014-01-01
It is well known that a decline of arousal level causes of poor performance of movements or judgments. Our previous study indicates that microsaccade (MS) rates and pupil fluctuations change before slow eye movements (SEMs) (Honda et al. 2013). However, SEM detection of this study was obscure and insufficient. In this study, we propose a new SEM detection method and analyze MS rates and pupil fluctuations while subjects maintain their gaze on a target. We modified Shin et al.'s method, which is optimized for EOG (electrooculography) signals, to extract the period of sustaining SEMs using a general eye tracker. After SEM detection, we analyzed MS rates and pupil fluctuations prior to the initiation of SEMs. As a result, we were able to detect SEMs more precisely than in our previous study. Moreover, the results of eye movements and pupil fluctuations analyses show that gradual rise of MS rate and longitudinal miosis are observed prior to the initiation of SEMs, which is consistent with our previous study. These findings suggest that monitoring eye movements and pupil fluctuations may evaluate the arousal level more precisely. Further, we found that these tendencies become more significant when they are restricted to the initial SEMs.
Wilkerson, J Michael; Iantaffi, Alex; Smolenski, Derek J; Brady, Sonya S; Horvath, Keith J; Grey, Jeremy A; Rosser, B R Simon
2012-01-01
While the effects of sexually explicit media (SEM) on heterosexuals' sexual intentions and behaviors have been studied, little is known about the consumption and possible influence of SEM among men who have sex with men (MSM). Importantly, conceptual models of how Internet-based SEM influences behavior are lacking. Seventy-nine MSM participated in online focus groups about their SEM viewing preferences and sexual behavior. Twenty-three participants reported recent exposure to a new behavior via SEM. Whether participants modified their sexual intentions and/or engaged in the new behavior depended on three factors: arousal when imagining the behavior, pleasure when attempting the behavior, and trust between sex partners. Based on MSM's experience, we advance a model of how viewing a new sexual behavior in SEM influences sexual intentions and behaviors. The model includes five paths. Three paths result in the maintenance of sexual intentions and behaviors. One path results in a modification of sexual intentions while maintaining previous sexual behaviors, and one path results in a modification of both sexual intentions and behaviors. With this model, researchers have a framework to test associations between SEM consumption and sexual intentions and behavior, and public health programs have a framework to conceptualize SEM-based HIV/STI prevention programs.
Selenomethionine incorporation into amyloid sequences regulates fibrillogenesis and toxicity.
Martínez, Javier; Lisa, Silvia; Sánchez, Rosa; Kowalczyk, Wioleta; Zurita, Esther; Teixidó, Meritxell; Giralt, Ernest; Andreu, David; Avila, Jesús; Gasset, María
2011-01-01
The capacity of a polypeptide chain to engage in an amyloid formation process and cause a conformational disease is contained in its sequence. Some of the sequences undergoing fibrillation contain critical methionine (Met) residues which in vivo can be synthetically substituted by selenomethionine (SeM) and alter their properties. Using peptide synthesis, biophysical techniques and cell viability determinations we have studied the effect of the substitution of methionine (Met) by selenomethionine (SeM) on the fibrillogenesis and toxic properties of Aβ40 and HuPrP(106-140). We have found that the effects display site-specificity and vary from inhibition of fibrillation and decreased toxicity ([SeM(35)]Aβ40, [SeM(129)]HuPrP(106-140) and [SeM(134)]HuPrP(106-140)), retarded assembly, modulation of polymer shape and retention of toxicity ([SeM(112)]HuPrP(106-140) to absence of effects ([SeM(109)]HuPrP(106-140)). This work provides direct evidence that the substitution of Met by SeM in proamyloid sequences has a major impact on their self-assembly and toxic properties, suggesting that the SeM pool can play a major role in dictating the allowance and efficiency of a polypeptide chain to undergo toxic polymerization.
Estudio de la galaxia peculiar NGC 1487
NASA Astrophysics Data System (ADS)
Agüero, E. L.; Paolantonio, S.; Gunthardt, G.
La galaxia peculiar NGC 1487, cuya morfología sugiere un evento de ``merging" o interacción próxima, es estudiada en base a material observacional espectroscópico y fotométrico obtenido en el CASLEO. Mediante técnicas espectrofotométricas standards se determinan las principales características espectrales, los mecanismos de excitación actuantes, las condiciones físicas y las velocidades radiales de las estructuras conspicuas de la galaxia. Por otra parte, usando imágenes directas en las bandas B, V, R e I, se obtienen distribuciones detalladas de los colores B-V, V-R y R-I y detalles de su morfología.
Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth
2018-02-01
Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2 = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2 = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.
Shyleshchandran, Mohanachandran Nair; Mohan, Mahesh; Ramasamy, Eswara Venkatesaperumal
2018-03-01
Contamination of estuarine system due to heavy metals is a severe issue in tropical countries, especially in India. For the evaluation of the risk due to heavy metals, the current study assessed spatial and temporal variation of acid-volatile sulfide (AVS), simultaneously extracted metal (SEM), and total metal concentration as toxicity indicator of aquatic sediments in Vembanad Lake System (VLS), India. Surface sediment samples collected from 12 locations from the northern portion of VLS for 4 years during different seasons. The results suggest, in post-monsoon season, 91% of the sampling locations possessed high bioavailability of metals and results in toxicity to aquatic biota. The average seasonal distribution of SEM during the period of observations was in the order post-monsoon > pre-monsoon > monsoon (1.76 ± 2.00 > 1.35 ± 0.60 > 0.80 ± 0.54 μmol/g). The concentration of individual metals on ∑SEM are in the order SEM Zn > SEM Cu> SEM Cd ≈ SEM Pb > SEM Hg. Considering annual ΣSEM/AVS ratio, 83% of the sites cross the critical value of 'One,' reveals that active sulfide phase of the sediment for fixing the metals is saturated. The molar ratio (differences between SEM and AVS) and its normalized organic carbon ratio reveals that in the post-monsoon season, about 42% of the sites are in the category of adverse effects are possible. The study suggests the toxicity and mobility of the metals largely depend on the available AVS, and the current situation may pose harm to benthic organisms.
Endoscopic management of occluded metal biliary stents: Metal versus 10F plastic stents
Yoon, Won Jae; Ryu, Ji Kon; Lee, Jung Won; Ahn, Dong-Won; Kim, Yong-Tae; Yoon, Yong Bum; Woo, Sang Myung; Lee, Woo Jin
2010-01-01
AIM: To compare the efficacy of self-expandable metal stents (SEMSs) with 10F plastic stents (PSs) in the endoscopic management of occluded SEMSs. METHODS: We retrospectively reviewed the medical records of 56 patients who underwent SEMS insertion for palliation of unresectable malignant biliary obstruction between 2000 and 2007 and subsequent endoscopic retrograde biliary drainage (ERBD) with SEMS or PS for initial SEMS occlusion between 2000 and 2008. RESULTS: Subsequent ERBD with SEMS was performed in 29 patients and with PS in 27. The median time to stent occlusion after subsequent ERBD was 186 d in the SEMS group and 101 d in the PS group (P = 0.118). Overall median stent patency was 79 d for the SEMS group and 66 d for the PS group (P = 0.379). The mean number of additional biliary drainage procedures after subsequent ERBD in patients that died (n = 50) during the study period was 2.54 ± 4.12 for the SEMS group and 1.85 ± 1.95 for the PS group (P = 0.457). The mean total cost of additional biliary drainage procedures after the occlusion of subsequent SEMS or PS was $410.04 ± 692.60 for the SEMS group and $630.16 ± 671.63 for the PS group (P = 0.260). Tumor ingrowth as the cause of initial SEMS occlusion was the only factor associated with a shorter time to subsequent stent occlusion (101 d for patients with tumor ingrowth vs 268 d for patients without tumor ingrowth, P = 0.008). CONCLUSION: Subsequent ERBD with PSs offered similar patency and number of additional biliary drainage procedures compared to SEMSs in the management of occluded SEMS. PMID:21072899
Endoscopic management of occluded metal biliary stents: metal versus 10F plastic stents.
Yoon, Won Jae; Ryu, Ji Kon; Lee, Jung Won; Ahn, Dong-Won; Kim, Yong-Tae; Yoon, Yong Bum; Woo, Sang Myung; Lee, Woo Jin
2010-11-14
To compare the efficacy of self-expandable metal stents (SEMSs) with 10F plastic stents (PSs) in the endoscopic management of occluded SEMSs. We retrospectively reviewed the medical records of 56 patients who underwent SEMS insertion for palliation of unresectable malignant biliary obstruction between 2000 and 2007 and subsequent endoscopic retrograde biliary drainage (ERBD) with SEMS or PS for initial SEMS occlusion between 2000 and 2008. Subsequent ERBD with SEMS was performed in 29 patients and with PS in 27. The median time to stent occlusion after subsequent ERBD was 186 d in the SEMS group and 101 d in the PS group (P = 0.118). Overall median stent patency was 79 d for the SEMS group and 66 d for the PS group (P = 0.379). The mean number of additional biliary drainage procedures after subsequent ERBD in patients that died (n = 50) during the study period was 2.54 ± 4.12 for the SEMS group and 1.85 ± 1.95 for the PS group (P = 0.457). The mean total cost of additional biliary drainage procedures after the occlusion of subsequent SEMS or PS was $410.04 ± 692.60 for the SEMS group and $630.16 ± 671.63 for the PS group (P = 0.260). Tumor ingrowth as the cause of initial SEMS occlusion was the only factor associated with a shorter time to subsequent stent occlusion (101 d for patients with tumor ingrowth vs 268 d for patients without tumor ingrowth, P = 0.008). Subsequent ERBD with PSs offered similar patency and number of additional biliary drainage procedures compared to SEMSs in the management of occluded SEMS.
Anisimowicz, Yvonne; O'Sullivan, Lucia F
2017-04-01
The Internet and mobile computing have been highly influential in shaping the modern technological era and subsequently the production of and access to online sexually explicit materials (SEM). Fandom-the realm of fans sharing a common interest-has also adapted to the Internet, which has changed how fans access and distribute fanworks (i.e., material created by fans such as stories and art), many of which contain SEM. The current study examined gender differences in the use and creation of online SEM by surveying 468 men and 347 women (ages 18 or older; mean age = 33.8 years) residing in North America. Participants completed anonymous measures assessing demographic information, experiences using and creating online SEM, and measures of related sexual attitudes. Use of online SEM was widely reported by participants, with men (87.8 %) indicating more use than with women (67.4 %). As expected, few participants reported creating online SEM (3.6 % of men, 4.9 % of women). Men and women reported similar levels of preferred sexual explicitness in the online SEM that they used. There were no significant gender differences in the use of fanworks reported by men (14.3 %) and women (14.7 %) or in the creation of fanworks (1.5 % of men, 3.2 % of women). Fandom-related online SEM use was predicted only by more permissive sexual attitudes (one of eight predictors). Although there were many similarities between men's and women's use of online SEM, some gender differences were found in their motives for online SEM use. Findings are discussed in terms of the context in which men and women experience online SEM.
PHOTOMICROPHOTOGRAPHY- GEOLOGY ( SEM)
1972-10-13
PHOTOMICROPHOTOGRAPHY -GEOLOGY (SEM) High magnification and resolution views of lunar, meteorite and terrestrial materials using the Scanning Electron MIcroscope (SEM), Bldg. 31 Planetary and Earth Science Laboratory.
Growth restriction and gender influence cerebral oxygenation in preterm neonates.
Cohen, Emily; Baerts, Willem; Alderliesten, Thomas; Derks, Jan; Lemmers, Petra; van Bel, Frank
2016-03-01
To investigate the effect of fetal growth restriction and gender on cerebral oxygenation in preterm neonates during the first 3 days of life. Case-control study. Neonatal Intensive Care Unit of the Wilhelmina Children's Hospital, The Netherlands. 68 (41 males) small for gestational age (SGA) (birth weight <10th percentile) and 136 (82 males) appropriate for gestational age (AGA) (birth weight 20th-80th percentile) neonates, matched for gender, gestational age, ventilatory and blood pressure support. Regional cerebral oxygen saturation (rScO2) and cerebral fractional tissue oxygen extraction (cFTOE) as measured by near-infrared spectroscopy throughout the first 72 h of life were compared between SGA and AGA neonates. The effect of gender was also explored within these comparisons. SGA neonates demonstrated higher rScO2 (71% SEM 0.2 vs 68% SEM 0.2) and lower cFTOE (0.25 SEM 0.002 vs 0.29 SEM 0.002) than AGA neonates. There was an independent effect of gender on rScO2 and cFTOE, resulting in the finding that SGA males displayed highest rScO2 and lowest cFTOE (73% SEM 0.3 respectively 0.24 SEM 0.003). AGA males and SGA females showed comparable rScO2 (69% SEM 0.2 vs 69% SEM 0.4) and cFTOE (0.28 SEM 0.002 vs 0.28 SEM 0.004). AGA females showed lowest rScO2 and highest cFTOE (66% SEM 0.2 respectively 0.30 SEM 0.002). Growth restriction and gender influence cerebral oxygenation and oxygen extraction in preterm neonates throughout the first 3 days of life. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Leal-Junior, Ernesto Cesar Pinto; de Almeida, Patrícia; Tomazoni, Shaiane Silva; de Carvalho, Paulo de Tarso Camillo; Lopes-Martins, Rodrigo Álvaro Brandão; Frigo, Lucio; Joensen, Jon; Johnson, Mark I; Bjordal, Jan Magnus
2014-01-01
To evaluate the effects of preventive treatment with low-level laser therapy (LLLT) on progression of dystrophy in mdx mice. Ten animals were randomly divided into 2 experimental groups treated with superpulsed LLLT (904 nm, 15 mW, 700 Hz, 1 J) or placebo-LLLT at one point overlying the tibialis anterior muscle (bilaterally) 5 times per week for 14 weeks (from 6th to 20th week of age). Morphological changes, creatine kinase (CK) activity and mRNA gene expression were assessed in animals at 20th week of age. Animals treated with LLLT showed very few morphological changes in skeletal muscle, with less atrophy and fibrosis than animals treated with placebo-LLLT. CK was significantly lower (p=0.0203) in animals treated with LLLT (864.70 U.l-1, SEM 226.10) than placebo (1708.00 U.l-1, SEM 184.60). mRNA gene expression of inflammatory markers was significantly decreased by treatment with LLLT (p<0.05): TNF-α (placebo-control=0.51 µg/µl [SEM 0.12], - LLLT=0.048 µg/µl [SEM 0.01]), IL-1β (placebo-control=2.292 µg/µl [SEM 0.74], - LLLT=0.12 µg/µl [SEM 0.03]), IL-6 (placebo-control=3.946 µg/µl [SEM 0.98], - LLLT=0.854 µg/µl [SEM 0.33]), IL-10 (placebo-control=1.116 µg/µl [SEM 0.22], - LLLT=0.352 µg/µl [SEM 0.15]), and COX-2 (placebo-control=4.984 µg/µl [SEM 1.18], LLLT=1.470 µg/µl [SEM 0.73]). Irradiation of superpulsed LLLT on successive days five times per week for 14 weeks decreased morphological changes, skeletal muscle damage and inflammation in mdx mice. This indicates that LLLT has potential to decrease progression of Duchenne muscular dystrophy.
Tan, Wei Shuan Kimberly; Tan, Wei Jie Kevin; Ponnalagu, Shalini D/O; Koecher, Katie; Menon, Ravi; Tan, Sze-Yen; Henry, Christiani J
2018-05-01
A low-glycaemic-index (GI) breakfast has been shown to lower blood glucose levels throughout the day. A wide variety of breakfast foods are consumed, but their GI values are largely unknown, hence limiting consumers' ability to select healthier options. This study investigated the GI values of ten common breakfast (five Asian and five Western) foods in this region using a randomised, cross-over study design. Participants arrived after an overnight fast, and fasting blood sample was taken before participants consumed test foods. Next, blood samples were taken at fixed intervals for 180 min. Glycaemic and insulinaemic responses to test foods were calculated as incremental AUC over 120 min, which were subsequently reported as glycaemic and insulinaemic indices. In all, nineteen healthy men (nine Chinese and ten Indians) aged 24·7 (sem 0·4) years with a BMI of 21·7 (sem 0·4) kg/m2 completed the study. Asian breakfast foods were of medium (white bun filled with red bean paste=58 (sem 4); Chinese steamed white bun=58 (sem 3)) to high GI (rice idli=85 (sem 4); rice dosa=76 (sem 5); upma=71 (sem 6)), whereas Western breakfast foods were all of low GI (whole-grain biscuit=54 (sem 5); whole-grain biscuit filled with peanut butter=44 (sem 3); whole-grain oat muesli=55 (sem 4); whole-grain oat protein granola=51 (sem 4); whole-grain protein cereal=49 (sem 3)). The GI of test foods negatively correlated with protein (r s -0·366), fat (r s -0·268) and dietary fibre (r s -0·422) (all P<0·001). GI values from this study contribute to the worldwide GI database, and may assist healthcare professionals in recommending low-GI breakfast to assist in lower daily glycaemia among Asians who are susceptible to type 2 diabetes mellitus.
Pregnancy augments hepatic glucose storage in response to a mixed meal
Moore, Mary Courtney; Smith, Marta S.; Connolly, Cynthia C.
2013-01-01
Studies were carried out on conscious female non-pregnant (NP) and pregnant (P; third-trimester) dogs (n 16; eight animals per group) to define the role of the liver in mixed meal disposition with arteriovenous difference and tracer techniques. Hepatic and hindlimb substrate disposal was assessed for 390 min during and after an intragastric mixed meal infusion labelled with [14C]glucose. The P dogs exhibited postprandial hyperglycaemia compared with NP dogs (area under the curve (AUC; change from basal over 390 min) of arterial plasma glucose: 86 680 (sem 12 140) and 187 990 (sem 33 990) mg/l in NP and P dogs, respectively; P<0·05). Plasma insulin concentrations did not differ significantly between the groups (AUC: 88 230 (sem 16 314) and 69 750 (sem 19 512) pmol/l in NP and P dogs, respectively). Net hepatic glucose uptake totalled 3691 (sem 508) v. 5081 (sem 1145) mg/100 g liver in NP and P dogs, respectively (P=0·38). The AUC of glucose oxidation by the gut and hindlimb were not different in NP and P dogs, but hepatic glucose oxidation (84 (sem 13) v. 206 (sem 30) mg/100 g liver) and glycogen synthesis (0·4 (sem 0·5) v. 26 (sem 0·7) g/100 g liver) were greater in P dogs (P<0·05). The proportion of hepatic glycogen deposited via the direct pathway did not differ between the groups. Hindlimb glucose uptake and skeletal muscle glycogen synthesis was similar between the groups, although final glycogen concentrations were higher in NP dogs (9·6 (sem 0·6) v. 70 (sem 0·6) mg/g muscle; P<0·05). Thus, hepatic glucose oxidation and glycogen storage were augmented in late pregnancy. Enhanced hepatic glycogen storage following a meal probably facilitates the maintenance of an adequate glucose supply to maternal and fetal tissues during the post-absorptive period PMID:21831337
Leal-Junior, Ernesto Cesar Pinto; de Almeida, Patrícia; Tomazoni, Shaiane Silva; de Carvalho, Paulo de Tarso Camillo; Lopes-Martins, Rodrigo Álvaro Brandão; Frigo, Lucio; Joensen, Jon; Johnson, Mark I.; Bjordal, Jan Magnus
2014-01-01
Aim To evaluate the effects of preventive treatment with low-level laser therapy (LLLT) on progression of dystrophy in mdx mice. Methods Ten animals were randomly divided into 2 experimental groups treated with superpulsed LLLT (904 nm, 15 mW, 700 Hz, 1 J) or placebo-LLLT at one point overlying the tibialis anterior muscle (bilaterally) 5 times per week for 14 weeks (from 6th to 20th week of age). Morphological changes, creatine kinase (CK) activity and mRNA gene expression were assessed in animals at 20th week of age. Results Animals treated with LLLT showed very few morphological changes in skeletal muscle, with less atrophy and fibrosis than animals treated with placebo-LLLT. CK was significantly lower (p = 0.0203) in animals treated with LLLT (864.70 U.l−1, SEM 226.10) than placebo (1708.00 U.l−1, SEM 184.60). mRNA gene expression of inflammatory markers was significantly decreased by treatment with LLLT (p<0.05): TNF-α (placebo-control = 0.51 µg/µl [SEM 0.12], - LLLT = 0.048 µg/µl [SEM 0.01]), IL-1β (placebo-control = 2.292 µg/µl [SEM 0.74], - LLLT = 0.12 µg/µl [SEM 0.03]), IL-6 (placebo-control = 3.946 µg/µl [SEM 0.98], - LLLT = 0.854 µg/µl [SEM 0.33]), IL-10 (placebo-control = 1.116 µg/µl [SEM 0.22], - LLLT = 0.352 µg/µl [SEM 0.15]), and COX-2 (placebo-control = 4.984 µg/µl [SEM 1.18], LLLT = 1.470 µg/µl [SEM 0.73]). Conclusion Irradiation of superpulsed LLLT on successive days five times per week for 14 weeks decreased morphological changes, skeletal muscle damage and inflammation in mdx mice. This indicates that LLLT has potential to decrease progression of Duchenne muscular dystrophy. PMID:24599021
2018-01-01
Fibromyalgia syndrome (FMS) is a highly prevalent, chronic musculoskeletal condition characterized by widespread pain and evoked pain at tender points. This study evaluated various aspects of body awareness in a sample of 14 women with FMS and 13 healthy controls, such as plasticity of the body schema, body esteem, and interoceptive awareness. To this end, the Rubber Hand Illusion (RHI), the Body Esteem Scale (BES), and the Body Perception Questionnaire (BPQ) were used, respectively. Consistent with increased plasticity of the body schema, FMS patients scored higher, with large or very large effect sizes, across all three domains evaluated in the RHI paradigm, namely proprioceptive drift and perceived ownership and motor control over the rubber hand. Scores on all items addressed by the BES were consistently lower among FMS subjects (2.52, SEM .19 vs 3.89, SEM .16, respectively, p < .01, Cohen’s d = .38-.66). In the FMS sample, BES scores assigned to most painful regions also were lower than those assigned to the remaining body sites (1.58, SEM .19 vs 2.87, SEM .18, respectively, p < .01). Significantly higher scores (p < .01, Cohen’s d = .51-.87) were found in the FMS sample across awareness (3.57 SEM .15 vs 1.87 SEM .11), stress response (3.76 SEM .11 vs 1.78 SEM .11), autonomic nervous system reactivity (2.59 SEM .17 vs 1.35 SEM .07), and stress style 2 (2.73 SEM .27 vs 1.13 SEM .04) subscales of the BPQ. Intensity of ongoing clinical pain was found to be strongly correlated with interoceptive awareness (r = .75, p = .002). The results suggest a disturbed embodiment in FMS, characterized by instability of the body schema, negatively biased cognitions regarding one’s own body, and increased vigilance to internal bodily cues. These manifestations may be interpreted as related with the inability of incoming sensory inputs to adequately update negatively biased off-line somatorepresentations stored as long-term memory. PMID:29624596
3D imaging of cells and tissues by focused ion beam/scanning electron microscopy (FIB/SEM).
Drobne, Damjana
2013-01-01
Integration of a scanning electron microscope (SEM) and focused ion beam (FIB) technology into a single FIB/SEM system permits use of the FIB as a nano-scalpel to reveal site-specific subsurface microstructures which can be examined in great detail by SEM. The FIB/SEM technology is widely used in the semiconductor industry and material sciences, and recently its use in the life sciences has been initiated. Samples for FIB/SEM investigation can be either embedded in a plastic matrix, the traditional means of preparation of transmission electron microscopy (TEM) specimens, or simply dried as in samples prepared for SEM imaging. Currently, FIB/SEM is used in the life sciences for (a) preparation by the lift-out technique of lamella for TEM analysis, (b) tomography of samples embedded in a matrix, and (c) in situ site-specific FIB milling and SEM imaging using a wide range of magnifications. Site-specific milling and imaging has attracted wide interest as a technique in structural research of single eukaryotic and prokaryotic cells, small animals, and different animal tissue, but it still remains to be explored more thoroughly. In the past, preparation of samples for site-specific milling and imaging by FIB/SEM has typically adopted the embedding techniques used for TEM samples, and which have been very well described in the literature. Sample preparation protocols for the use of dried samples in FIB/SEM have been less well investigated. The aim of this chapter is to encourage application of FIB/SEM on dried biological samples. A detailed description of conventional dried sample preparation and FIB/SEM investigation of dried biological samples is presented. The important steps are described and illustrated, and direct comparison between embedded and dried samples of same tissues is provided. The ability to discover links between gross morphology of the tissue or organ, surface characteristics of any selected region, and intracellular structural details on the nanometer scale is an appealing application of electron microscopy in the life sciences and merits further exploration.
Cho, Jae Hee; Jeon, Tae Joo; Park, Jeong Youp; Kim, Hee Man; Kim, Yoon Jae; Park, Seung Woo; Chung, Jae Bock; Song, Si Young; Bang, Seungmin
2011-02-01
The self-expandable metallic stent (SEMS) has been widely used for unresectable malignant biliary obstruction but eventually becomes occluded by tumor ingrowth/overgrowth and sludge. Therefore, we aimed to determine the therapeutic effectiveness of secondary stents and to find differences according to various combinations of the first and second stents for the management of occluded SEMSs in patients with malignant distal biliary obstruction. Between 1999 and November 2008, 77 patients with malignant biliary obstruction underwent secondary biliary stent placement as "stent-in-stent" at three university hospitals in Korea (40 covered, 26 uncovered, and 11 plastic stents). The membrane of the covered SEMS was regarded as the barrier against tumor ingrowth. We categorized the patients into three groups based on whether the covered SEMS was either the first or the second stent: membrane-SEMS (18 covered-covered; 9 covered-uncovered; 22 uncovered-covered SEMS), bare-SEMS (17 uncovered-uncovered SEMS), and plastic stent (3 covered-plastic; 8 uncovered-plastic). The median patency of second stents was 138, 109, and 88 days (covered, uncovered, and plastic stents). The second covered SEMSs had a significantly longer patency than plastic stents (p=0.047). In a multivariate analysis including membrane-SEMS, bare-SEMS, and plastic stent groups, the bare-SEMS had a worse cumulative stent patency (HR=2.04, CI=1.08-3.86) and survival time (HR=2.37, CI=1.25-4.49) than the membrane-SEMS. Patients with ampulla of Vater cancer had better stent patency (HR=0.27, CI=0.08-0.98) and survival (HR=0.17, CI=0.04-0.77) than those with other pancreatobiliary malignancies. In addition, antitumor treatment prolonged survival time (HR=0.50, CI=0.26-0.99). The placement of additional biliary stents using the "stent-in-stent" method is an effective treatment for an occluded metallic primary stent. In addition, double biliary SEMS placement using at least one covered SEMS (in the primary and/or secondary procedure) might provide longer cumulative stent patency and survival than using uncovered SEMSs in both procedures.
Liu, Haichuan; Usmani, Shariq M.; Neidleman, Jason; Müller, Janis A.; Avila-Herrera, Aram; Gawanbacht, Ali; Zirafi, Onofrio; Chu, Simon; Dong, Ming; Kumar, Senthil T.; Smith, James F.; Pollard, Katherine S.; Fändrich, Marcus; Kirchhoff, Frank; Münch, Jan; Witkowska, H. Ewa; Greene, Warner C.
2014-01-01
ABSTRACT Semen enhances HIV infection in vitro, but how long it retains this activity has not been carefully examined. Immediately postejaculation, semen exists as a semisolid coagulum, which then converts to a more liquid form in a process termed liquefaction. We demonstrate that early during liquefaction, semen exhibits maximal HIV-enhancing activity that gradually declines upon further incubation. The decline in HIV-enhancing activity parallels the degradation of peptide fragments derived from the semenogelins (SEMs), the major components of the coagulum that are cleaved in a site-specific and progressive manner upon initiation of liquefaction. Because amyloid fibrils generated from SEM fragments were recently demonstrated to enhance HIV infection, we set out to determine whether any of the liquefaction-generated SEM fragments associate with the presence of HIV-enhancing activity. We identify SEM1 from amino acids 86 to 107 [SEM1(86-107)] to be a short, cationic, amyloidogenic SEM peptide that is generated early in the process of liquefaction but that, conversely, is lost during prolonged liquefaction due to the activity of serine proteases. Synthetic SEM1(86-107) amyloids directly bind HIV-1 virions and are sufficient to enhance HIV infection of permissive cells. Furthermore, endogenous seminal levels of SEM1(86-107) correlate with donor-dependent variations in viral enhancement activity, and antibodies generated against SEM1(86-107) recognize endogenous amyloids in human semen. The amyloidogenic potential of SEM1(86-107) and its virus-enhancing properties are conserved among great apes, suggesting an evolutionarily conserved function. These studies identify SEM1(86-107) to be a key, HIV-enhancing amyloid species in human semen and underscore the dynamic nature of semen's HIV-enhancing activity. IMPORTANCE Semen, the most common vehicle for HIV transmission, enhances HIV infection in vitro, but how long it retains this activity has not been investigated. Semen naturally undergoes physiological changes over time, whereby it converts from a gel-like consistency to a more liquid form. This process, termed liquefaction, is characterized at the molecular level by site-specific and progressive cleavage of SEMs, the major components of the coagulum, by seminal proteases. We demonstrate that the HIV-enhancing activity of semen gradually decreases over the course of extended liquefaction and identify a naturally occurring semenogelin-derived fragment, SEM1(86-107), whose levels correlate with virus-enhancing activity over the course of liquefaction. SEM1(86-107) amyloids are naturally present in semen, and synthetic SEM1(86-107) fibrils bind virions and are sufficient to enhance HIV infection. Therefore, by characterizing dynamic changes in the HIV-enhancing activity of semen during extended liquefaction, we identified SEM1(86-107) to be a key virus-enhancing component of human semen. PMID:24741080
Characteristics of different frequency ranges in scanning electron microscope images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sim, K. S., E-mail: kssim@mmu.edu.my; Nia, M. E.; Tan, T. L.
2015-07-22
We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement.
Structural Equation Model Trees
Brandmaier, Andreas M.; von Oertzen, Timo; McArdle, John J.; Lindenberger, Ulman
2015-01-01
In the behavioral and social sciences, structural equation models (SEMs) have become widely accepted as a modeling tool for the relation between latent and observed variables. SEMs can be seen as a unification of several multivariate analysis techniques. SEM Trees combine the strengths of SEMs and the decision tree paradigm by building tree structures that separate a data set recursively into subsets with significantly different parameter estimates in a SEM. SEM Trees provide means for finding covariates and covariate interactions that predict differences in structural parameters in observed as well as in latent space and facilitate theory-guided exploration of empirical data. We describe the methodology, discuss theoretical and practical implications, and demonstrate applications to a factor model and a linear growth curve model. PMID:22984789
O'Halloran, P; Tzortziou Brown, V; Morgan, K; Maffulli, N; Perry, M; Morrissey, D
2009-12-01
To investigate the opinions of general practitioners, orthopaedic surgeons, rheumatologists, sport and exercise medicine (SEM) registrars and public health consultants on training, caseload, the most appropriate setting and the position of SEM within the National Health Service (NHS) in the UK. A cross-sectional questionnaire-based survey investigated the opinions of the above professionals from three primary care trusts and associated hospitals in London and Birmingham. With a 50% response rate (n = 226), 93% (208/224) of participants felt that there was a role for SEM in the NHS. 56% (124/223) agreed that this role should be in both primary and secondary care. 64% (136/212) of participants felt that their practice would benefit from the input of a SEM physician and 95% (191/202) would consider referring patients to SEM services. 74% (165/222) agreed that SEM should have a public health role, and 63% (140/222) believed that these responsibilities should be evenly balanced with the treatment of sports injuries. Despite the emphasis on public health work from SEM policy makers, none of the SEM registrars selected public health as an important training area. 31% (44/140) of participants felt that a lack of education in the medical profession regarding SEM represented the greatest hindrance to its development in the NHS. Several areas of agreement were demonstrated across the specialties, many of which matched the views of policy makers. This study involved participants from a range of cognate disciplines and was the first to investigate this issue since SEM was recognised as a specialty in 2005.
Lindahl, Susanne; Söderlund, Robert; Frosth, Sara; Pringle, John; Båverud, Viveca; Aspán, Anna
2011-11-21
Strangles is a serious respiratory disease in horses caused by Streptococcus equi subspecies equi (S. equi). Transmission of the disease occurs by direct contact with an infected horse or contaminated equipment. Genetically, S. equi strains are highly homogenous and differentiation of strains has proven difficult. However, the S. equi M-protein SeM contains a variable N-terminal region and has been proposed as a target gene to distinguish between different strains of S. equi and determine the source of an outbreak. In this study, strains of S. equi (n=60) from 32 strangles outbreaks in Sweden during 1998-2003 and 2008-2009 were genetically characterized by sequencing the SeM protein gene (seM), and by pulsed-field gel electrophoresis (PFGE). Swedish strains belonged to 10 different seM types, of which five have not previously been described. Most were identical or highly similar to allele types from strangles outbreaks in the UK. Outbreaks in 2008/2009 sharing the same seM type were associated by geographic location and/or type of usage of the horses (racing stables). Sequencing of the seM gene generally agreed with pulsed-field gel electrophoresis profiles. Our data suggest that seM sequencing as a epidemiological tool is supported by the agreement between seM and PFGE and that sequencing of the SeM protein gene is more sensitive than PFGE in discriminating strains of S. equi. Copyright © 2011 Elsevier B.V. All rights reserved.
Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya
2015-01-01
Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Toshimitsu, Fumiyuki; Nakashima, Naotoshi
2015-12-14
The ideal form of semiconducting-single-walled carbon nanotubes (sem-SWNTs) for science and technology is long, defect-free, chirality pure and chemically pure isolated narrow diameter tubes. While various techniques to solubilize and purify sem-SWNTs have been developed, many of them targeted only the chiral- or chemically-purity while sacrificing the sem-SWNT intrinsic structural identities by applying strong ultra-sonication and/or chemical modifications. Toward the ultimate purification of the sem-SWNTs, here we report a mild-conditioned extraction of the sem-SWNTs using removable supramolecular hydrogen-bonding polymers (HBPs) that are composed of dicarboxylic- or diaminopyridyl-fluorenes with ~70%-(8,6)SWNT selective extraction. Replacing conventional strong sonication techniques by a simple shaking using HPBs was found to provide long sem-SWNTs (>2.0 μm) with a very high D/G ratio, which was determined by atomic force microscopy observations. The HBPs were readily removed from the nanotube surfaces by an outer stimulus, such as a change in the solvent polarities, to provide chemically pure (8,6)-enriched sem-SWNTs. We also describe molecular mechanics calculations to propose possible structures for the HBP-wrapped sem-SWNTs, furthermore, the mechanism of the chiral selectivity for the sorted sem-SWNTs is well explained by the relationship between the molecular surface area and mass of the HBP/SWNT composites.
Ishigaki, Yasuhito; Nakamura, Yuka; Oikawa, Yosaburo; Yano, Yasuhiro; Kuwabata, Susumu; Nakagawa, Hideaki; Tomosugi, Naohisa; Takegami, Tsutomu
2012-01-01
Scanning electron microscopes (SEM), which image sample surfaces by scanning with an electron beam, are widely used for steric observations of resting samples in basic and applied biology. Various conventional methods exist for SEM sample preparation. However, conventional SEM is not a good tool to observe living organisms because of the associated exposure to high vacuum pressure and electron beam radiation. Here we attempted SEM observations of live ticks. During 1.5×10−3 Pa vacuum pressure and electron beam irradiation with accelerated voltages (2–5 kV), many ticks remained alive and moved their legs. After 30-min observation, we removed the ticks from the SEM stage; they could walk actively under atmospheric pressure. When we tested 20 ticks (8 female adults and 12 nymphs), they survived for two days after SEM observation. These results indicate the resistance of ticks against SEM observation. Our second survival test showed that the electron beam, not vacuum conditions, results in tick death. Moreover, we describe the reaction of their legs to electron beam exposure. These findings open the new possibility of SEM observation of living organisms and showed the resistance of living ticks to vacuum condition in SEM. These data also indicate, for the first time, the usefulness of tick as a model system for biology under extreme condition. PMID:22431980
Wilkerson, J. Michael; Iantaffi, Alex; Smolenski, Derek J.; Brady, Sonya S.; Horvath, Keith J.; Grey, Jeremy A.; Rosser, B. R. Simon
2012-01-01
While the effects of sexually explicit media (SEM) on heterosexuals’ sexual intentions and behaviors have been studied, little is known about the consumption and possible influence of SEM among men who have sex with men (MSM). Importantly, conceptual models of how Internet-based SEM influences behavior are lacking. Seventy-nine MSM participated in online focus groups about their SEM viewing preferences and sexual behavior. Twenty-three participants reported recent exposure to a new behavior via SEM. Whether participants modified their sexual intentions and/or engaged in the new behavior depended on three factors: arousal when imagining the behavior, pleasure when attempting the behavior, and trust between sex partners. Based on MSM’s experience, we advance a model of how viewing a new sexual behavior in SEM influences sexual intentions and behaviors. The model includes five paths. Three paths result in the maintenance of sexual intentions and behaviors. One path results in a modification of sexual intentions while maintaining previous sexual behaviors, and one path results in a modification of both sexual intentions and behaviors. With this model, researchers have a framework to test associations between SEM consumption and sexual intentions and behavior, and public health programs have a framework to conceptualize SEM-based HIV/STI prevention programs. PMID:23185126
Two novel approaches to study arthropod anatomy by using dualbeam FIB/SEM.
Di Giulio, Andrea; Muzzi, Maurizio
2018-03-01
Transmission Electron Microscopy (TEM) has always been the conventional method to study arthropod ultrastructure, while the use of Scanning Electron Microscopy (SEM) was mainly devoted to the examination of the external cuticular structures by secondary electrons. The new generation field emission SEMs are capable to generate images at sub-cellular level, comparable to TEM images employing backscattered electrons. The potential of this kind of acquisition becomes very powerful in the dual beam FIB/SEM where the SEM column is combined with a Focused Ion Beam (FIB) column. FIB uses ions as a nano-scalpel to slice samples fixed and embedded in resin, replacing traditional ultramicrotomy. We here present two novel methods, which optimize the use of FIB/SEM for studying arthropod anatomy. Copyright © 2017 Elsevier Ltd. All rights reserved.
From patterns to causal understanding: Structural equation modeling (SEM) in soil ecology
Eisenhauer, Nico; Powell, Jeff R; Grace, James B.; Bowker, Matthew A.
2015-01-01
In this perspectives paper we highlight a heretofore underused statistical method in soil ecological research, structural equation modeling (SEM). SEM is commonly used in the general ecological literature to develop causal understanding from observational data, but has been more slowly adopted by soil ecologists. We provide some basic information on the many advantages and possibilities associated with using SEM and provide some examples of how SEM can be used by soil ecologists to shift focus from describing patterns to developing causal understanding and inspiring new types of experimental tests. SEM is a promising tool to aid the growth of soil ecology as a discipline, particularly by supporting research that is increasingly hypothesis-driven and interdisciplinary, thus shining light into the black box of interactions belowground.
GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM.
Bok, Jan; Lalinský, Ondřej; Hanuš, Martin; Onderišinová, Zuzana; Kelar, Jakub; Kučera, Miroslav
2016-04-01
Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications. Copyright © 2016 Elsevier B.V. All rights reserved.
2011-08-01
Specimen 625 -58 Cleaned with 50-ksi Water Jet ....................... 18 Figure 12. SEM Images of Inconel Specimen 626-63 Cleaned with 50-ksi Water...SEM Images of Inconel Specimen 626-22 Cleaned with Wet Glass Bead.......................... 21 Figure 15. SEM Images of Titanium Specimen 625 -02...Figure 18. SEM Images of Titanium Specimen 625 -40 Cleaned with Dry Al2O3 (240 grit) ............... 24 Figure 19. SEM Images of Inconel Specimen
Rinaldi, Mariano; Mezzano, Emilio; Berra, Matias S.; Parés, Herald R.; Olocco, Ricardo V.; Papalini, Francisco R.
2015-01-01
Objetivo: Describir nuestra experiencia en el manejo de las Mavs analizando las características clínicas de los pacientes y los resultados postoperatorios. Método de análisis: Realizamos un análisis retrospectivo de 52 pacientes admitidos en el Servicio de neurocirugía para manejo quirúrgico: La información de referencia incluyo síntomas al inicio, diagnostico de admisión, hallazgos neurológicos y hallazgos en estudio por imágenes tales como tomografía cerebral, IRM cerebral y angiografía por sustracción digital. Los hallazgos postoperatorios de interés fueron: Mortalidad, examen neurológico postoperatorio y complicaciones asociadas. Presentamos nuestro análisis estadístico. Resultados: Edad promedio: 37,7 años. Distribución: Hombres: 61,5%. Motivos de consulta más frecuentes: Cefalea 63,5%, evento hemorrágico 59,6%, convulsiones 26,9%. Localización: Supratentorial: 92,9%, Infratentorial: 7,2%. 30,8%, de las Mavs fueron grado 2 y grado 3 Cincuenta por ciento del total presentaron aneurismas, del total de la MAVs, 59,6% debutó con sangrado, 26,9% con Crisis Convulsivas y 13,5% con déficit neurológico. Recibieron tratamiento endovascular previo a cirugía 30,7%. Durante el postoperatorio 23,1% presentaron mejoría clínica, 57,7% no presento modificación, 19,2% empeoraron en el postoperatorio. La mortalidad fue 13,5%. Conclusión: Creemos que el subgrupo de Mavs grados III a V representan una entidad que requiere una compleja toma de decisiones dada la alta incidencia de aneurismas asociados que presentan y su asociación con eventos de sangrado. Nuestra mortalidad postoperatoria coincide con la bibliografía. Palabras clave, Mavs- aneurismas asociados- Acv hemorrágico- convulsiones. PMID:26600984
Eventos de Desconexao na Cauda de Plasma do Cometa P/Halley
NASA Astrophysics Data System (ADS)
Voelzke, M. R.; Fahr, H. J.
2001-08-01
Observacoes cometárias e de vento solar sao comparadas com o propósito de determinar-se as condicoes do vento solar associadas aos eventos de desconexao (DEs) observados em caudas de plasma cometárias. Os dados cometários sao provenientes do The International Halley Watch Atlas of Large-Scale Phenomena. A análise visual sistemática das imagens do atlas revelou, entre outras estruturas morfológicas, 47 DEs ao longo da cauda de plasma do P/Halley. Estes 47 DEs registrados em 47 imagens distintas permitiram a descoberta de 19 origens de DEs, ou seja, o tempo em que as desconexoes iniciaram foi calculado. Os dados do vento solar sao provenientes de medidas feitas in situ pela sonda espacial IMP-8, as quais foram usadas para elaborar a variacao da velocidade do vento solar, densidade e pressao dinâmica durante o intervalo analisado. O presente trabalho compara as atuais teorias conflitantes, baseadas nos mecanismos de formacao, com o intuito de explicar o fenômeno cíclico dos DEs, ou seja, os efeitos de producao iônica, os efeitos de pressao e os efeitos de reconexao magnética sao analisados. Para cada uma das 19 origens de DEs comparou-se a densidade com a respectiva velocidade do vento solar com o intuito de determinar-se uma possível correlacao entre estas origens e os efeitos de pressao dinâmica. Quando da ocorrência de 6 origens de DEs o IMP-8 nao realizou medidas, nos outros 13 casos 10 origens (77%) mostraram uma anticorrelacao entre velocidade e densidade e apenas 3 (23%) revelaram uma tendência similar entre velocidade e densidade. Portanto, a análise inicial demonstra uma fraca correlacao entre as origens dos DEs e os efeitos de pressao.
Assessing the utility of FIB-SEM images for shale digital rock physics
NASA Astrophysics Data System (ADS)
Kelly, Shaina; El-Sobky, Hesham; Torres-Verdín, Carlos; Balhoff, Matthew T.
2016-09-01
Shales and other unconventional or low permeability (tight) reservoirs house vast quantities of hydrocarbons, often demonstrate considerable water uptake, and are potential repositories for fluid sequestration. The pore-scale topology and fluid transport mechanisms within these nanoporous sedimentary rocks remain to be fully understood. Image-informed pore-scale models are useful tools for studying porous media: a debated question in shale pore-scale petrophysics is whether there is a representative elementary volume (REV) for shale models? Furthermore, if an REV exists, how does it differ among petrophysical properties? We obtain three dimensional (3D) models of the topology of microscale shale volumes from image analysis of focused ion beam-scanning electron microscope (FIB-SEM) image stacks and investigate the utility of these models as a potential REV for shale. The scope of data used in this work includes multiple local groups of neighboring FIB-SEM images of different microscale sizes, corresponding core-scale (milli- and centimeters) laboratory data, and, for comparison, series of two-dimensional (2D) cross sections from broad ion beam SEM images (BIB-SEM), which capture a larger microscale field of view than the FIB-SEM images; this array of data is larger than the majority of investigations with FIB-SEM-derived microscale models of shale. Properties such as porosity, organic matter content, and pore connectivity are extracted from each model. Assessments of permeability with single phase, pressure-driven flow simulations are performed in the connected pore space of the models using the lattice-Boltzmann method. Calculated petrophysical properties are compared to those of neighboring FIB-SEM images and to core-scale measurements of the sample associated with the FIB-SEM sites. Results indicate that FIB-SEM images below ∼5000 μm3 volume (the largest volume analyzed) are not a suitable REV for shale permeability and pore-scale networks; i.e. field of view is compromised at the expense of detailed, but often unconnected, nanopore morphology. Further, we find that it is necessary to acquire several local FIB-SEM or BIB-SEM images and correlate their extracted geometric properties to improve the likelihood of achieving representative values of porosity and organic matter volume. Our work indicates that FIB-SEM images of microscale volumes of shale are a qualitative tool for petrophysical and transport analysis. Finally, we offer alternatives for quantitative pore-scale assessments of shale.
Palta, Mari; Chen, Han-Yang; Kaplan, Robert M.; Feeny, David; Cherepanov, Dasha; Fryback, Dennis
2011-01-01
Background Standard errors of measurement (SEMs) of health related quality of life (HRQoL) indexes are not well characterized. SEM is needed to estimate responsiveness statistics and provides guidance on using indexes on the individual and group level. SEM is also a component of reliability. Purpose To estimate SEM of five HRQoL indexes. Design The National Health Measurement Study (NHMS) was a population based telephone survey. The Clinical Outcomes and Measurement of Health Study (COMHS) provided repeated measures 1 and 6 months post cataract surgery. Subjects 3844 randomly selected adults from the non-institutionalized population 35 to 89 years old in the contiguous United States and 265 cataract patients. Measurements The SF6-36v2™, QWB-SA, EQ-5D, HUI2 and HUI3 were included. An item-response theory (IRT) approach captured joint variation in indexes into a composite construct of health (theta). We estimated: (1) the test-retest standard deviation (SEM-TR) from COMHS, (2) the structural standard deviation (SEM-S) around the composite construct from NHMS and (3) corresponding reliability coefficients. Results SEM-TR was 0.068 (SF-6D), 0.087 (QWB-SA), 0.093 (EQ-5D), 0.100 (HUI2) and 0.134 (HUI3), while SEM-S was 0.071, 0.094, 0.084, 0.074 and 0.117, respectively. These translate into reliability coefficients for SF-6D: 0.66 (COMHS) and 0.71 (NHMS), for QWB: 0.59 and 0.64, for EQ-5D: 0.61 and 0.70 for HUI2: 0.64 and 0.80, and for HUI3: 0.75 and 0.77, respectively. The SEM varied considerably across levels of health, especially for HUI2, HUI3 and EQ-5D, and was strongly influenced by ceiling effects. Limitations Repeated measures were five months apart and estimated theta contain measurement error. Conclusions The two types of SEM are similar and substantial for all the indexes, and vary across the range of health. PMID:20935280
Palta, Mari; Chen, Han-Yang; Kaplan, Robert M; Feeny, David; Cherepanov, Dasha; Fryback, Dennis G
2011-01-01
Standard errors of measurement (SEMs) of health-related quality of life (HRQoL) indexes are not well characterized. SEM is needed to estimate responsiveness statistics, and is a component of reliability. To estimate the SEM of 5 HRQoL indexes. The National Health Measurement Study (NHMS) was a population-based survey. The Clinical Outcomes and Measurement of Health Study (COMHS) provided repeated measures. A total of 3844 randomly selected adults from the noninstitutionalized population aged 35 to 89 y in the contiguous United States and 265 cataract patients. The SF6-36v2™, QWB-SA, EQ-5D, HUI2, and HUI3 were included. An item-response theory approach captured joint variation in indexes into a composite construct of health (theta). The authors estimated 1) the test-retest standard deviation (SEM-TR) from COMHS, 2) the structural standard deviation (SEM-S) around theta from NHMS, and 3) reliability coefficients. SEM-TR was 0.068 (SF-6D), 0.087 (QWB-SA), 0.093 (EQ-5D), 0.100 (HUI2), and 0.134 (HUI3), whereas SEM-S was 0.071, 0.094, 0.084, 0.074, and 0.117, respectively. These yield reliability coefficients 0.66 (COMHS) and 0.71 (NHMS) for SF-6D, 0.59 and 0.64 for QWB-SA, 0.61 and 0.70 for EQ-5D, 0.64 and 0.80 for HUI2, and 0.75 and 0.77 for HUI3, respectively. The SEM varied across levels of health, especially for HUI2, HUI3, and EQ-5D, and was influenced by ceiling effects. Limitations. Repeated measures were 5 mo apart, and estimated theta contained measurement error. The 2 types of SEM are similar and substantial for all the indexes and vary across health.
Diversity of seM in Streptococcus equi subsp. equi isolated from strangles outbreaks.
Libardoni, Felipe; Vielmo, Andréia; Farias, Luana; Matter, Letícia Beatriz; Pötter, Luciana; Spilki, Fernando Rosado; de Vargas, Agueda Castagna
2013-03-23
Strangles is the main upper respiratory tract disease of horses. There are currently no studies on the changes in alleles of the M protein gene (seM) in Brazilian isolates of Streptococcus equi ssp. equi (S. equi). This study aimed to analyze and differentiate molecularly S. equi isolates from equine clinical specimens from southern Brazil, between 1994 and 2010. seM alleles were analyzed in 47 isolates of S. equi obtained from clinical cases of strangles (15 Thoroughbred horses, 29 Crioulo breed horses and three Brasileiro de Hipismo--BH). seM alleles characterization was performed by comparing variable region sequences of the seM gene. The alleles were also phylogenetically grouped by Neighbor-joining analysis, which demonstrated the geographic distribution of those in properties from southern Brazil. Fifteen alleles of the gene seM were found among the 47 S. equi isolates analyzed. Among these, only one allele (seM-61), which was identified in seven isolates (14.9%), was found in the database PubMLST-seM. Within the new alleles, allele seM-115 was the most prevalent, having been found in 13 isolates (27.7%), followed by allele seM-117 in 10 isolates (21.3%). In the Brazilian horse population studied, there is greater diversity of M protein alleles in S. equi isolates compared to worldwide data deposited in PubMLST-seM. Among the 15 seM alleles identified, only one allele sequence was previously published. The alleles identification is important to control the disease by guiding selection of strains for the manufacture of commercial and autogenous vaccines. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bekar, Kursat B; Miller, Thomas Martin; Patton, Bruce W
The characteristic X-rays produced by the interactions of the electron beam with the sample in a scanning electron microscope (SEM) are usually captured with a variable-energy detector, a process termed energy dispersive spectrometry (EDS). The purpose of this work is to exploit inverse simulations of SEM-EDS spectra to enable rapid determination of sample properties, particularly elemental composition. This is accomplished using penORNL, a modified version of PENELOPE, and a modified version of the traditional Levenberg Marquardt nonlinear optimization algorithm, which together is referred to as MOZAIK-SEM. The overall conclusion of this work is that MOZAIK-SEM is a promising method formore » performing inverse analysis of X-ray spectra generated within a SEM. As this methodology exists now, MOZAIK-SEM has been shown to calculate the elemental composition of an unknown sample within a few percent of the actual composition.« less
Stadler, Richard H; Verzegnassi, Ludovica; Seefelder, Walburga; Racault, Lucie
2015-01-01
A comprehensive global database on semicarbazide (SEM) in foodstuffs and food ingredients is presented, with over 4000 data collected in foods such as seafood (crustaceans, fish powders), meat (beef, chicken powders), dairy products (e.g. raw milk, milk powders, whey, sweet buttermilk powder, caseinate, yoghurt, cheese), honey and other ingredients. The results provide evidence that the presence of SEM in certain dairy ingredients (whey, milk protein concentrates) is a by-product of chemical reactions taking place during the manufacturing process. Of the dairy ingredients tested (c. 2000 samples), 5.3% showed traces of SEM > 0.5 µg/kg. The highest incidence of SEM-positive samples in the dairy category were whey (powders, liquid) and milk protein concentrates (35% positive), with up to 13 µg/kg measured in a whey powder. Sweet buttermilk powder and caseinate followed, with 27% and 9.3% positives, respectively. SEM was not detected in raw milk, or in yoghurt or cheese. Of the crustacean products (shrimp and prawn powders) tested, 44% were positive for SEM, the highest value measured at 284 µg/kg. Fish powders revealed an unexpectedly high incidence of positive samples (25%); in this case, fraudulent addition of shellfish shells or carry-over during processing cannot be excluded. Overall, the data provide new insights into the occurrence of SEM (for dairy products and fish powders), substantially strengthening the arguments that SEM in certain food categories is not a conclusive marker of the use of the illegal antibiotic nitrofurazone.
Structural Equation Modeling: A Framework for Ocular and Other Medical Sciences Research
Christ, Sharon L.; Lee, David J.; Lam, Byron L.; Diane, Zheng D.
2017-01-01
Structural equation modeling (SEM) is a modeling framework that encompasses many types of statistical models and can accommodate a variety of estimation and testing methods. SEM has been used primarily in social sciences but is increasingly used in epidemiology, public health, and the medical sciences. SEM provides many advantages for the analysis of survey and clinical data, including the ability to model latent constructs that may not be directly observable. Another major feature is simultaneous estimation of parameters in systems of equations that may include mediated relationships, correlated dependent variables, and in some instances feedback relationships. SEM allows for the specification of theoretically holistic models because multiple and varied relationships may be estimated together in the same model. SEM has recently expanded by adding generalized linear modeling capabilities that include the simultaneous estimation of parameters of different functional form for outcomes with different distributions in the same model. Therefore, mortality modeling and other relevant health outcomes may be evaluated. Random effects estimation using latent variables has been advanced in the SEM literature and software. In addition, SEM software has increased estimation options. Therefore, modern SEM is quite general and includes model types frequently used by health researchers, including generalized linear modeling, mixed effects linear modeling, and population average modeling. This article does not present any new information. It is meant as an introduction to SEM and its uses in ocular and other health research. PMID:24467557
Slow eye movements distribution during nocturnal sleep.
Pizza, Fabio; Fabbri, Margherita; Magosso, Elisa; Ursino, Mauro; Provini, Federica; Ferri, Raffaele; Montagna, Pasquale
2011-08-01
To assess the distribution across nocturnal sleep of slow eye movements (SEMs). We evaluated SEMs distribution in the different sleep stages, and across sleep cycles in nocturnal recordings of 10 healthy women. Sleep was scored according to standard criteria, and the percentage of time occupied by the SEMs was automatically detected. SEMs were differently represented during sleep stages with the following order: wakefulness after sleep onset (WASO): 61%, NREM sleep stage 1: 54%, REM sleep: 43%, NREM sleep stage 2: 21%, NREM sleep stage 3: 7%, and NREM sleep stage 4: 3% (p<0.0001). There was no difference between phasic and tonic REM sleep. SEMs progressively decreased across the NREM sleep cycles (38%, 15%, 13% during NREM sleep stage 2 in the first three sleep cycles, p=0.006), whereas no significant difference was found for REM, NREM sleep stage 1, slow-wave sleep and WASO. Our findings confirm that SEMs are a phenomenon typical of the sleep onset period, but are also found in REM sleep. The nocturnal evolution of SEMs during NREM sleep stage 2 parallels the homeostatic process underlying slow-wave sleep. SEMs are a marker of sleepiness and, potentially, of sleep homeostasis. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
TRÆEN, BENTE; NOOR, SYED W.; HALD, GERT MARTIN; SIMON ROSSER, B. R.; BRADY, SONYA S.; ERICKSON, DARIN; GALOS, DYLAN L.; GREY, JEREMY A.; HORVATH, KEITH J.; IANTAFFI, ALEX; KILIAN, GUDRUNA; WILKERSON, J. MICHAEL
2017-01-01
The purpose of this study was to investigate consumption patterns of gay-oriented sexually explicit media (SEM) among men who have sex with men (MSM) in Norway, with a particular emphasis on a possible relationship between gay SEM consumption and HIV risk behavior. Participants included 529 MSM living in Norway recruited online to complete a SEM consumption and sexual risk survey. Of the 507 participants who responded to the all items measuring exposure to SEM, 19% reported unprotected anal intercourse with a casual partner (UAI) in last 90 days, and 14% reported having had sero-discordant UAI. Among those with UAI experience, 23% reported receptive anal intercourse (R-UAI) and 37% reported insertive anal intercourse (I-UAI). SEM consumption was found to be significantly associated with sexual risk behaviors. Participants with increased consumption of bareback SEM reported higher odds of UAI and I-UAI after adjusting for other factors using multivariable statistics. MSM who started using SEM at a later age reported lower odds of UAI and I-UAI than MSM who started earlier. Future research should aim at understanding how MSM develop and maintain SEM preferences and the relationship between developmental and maintenance factors and HIV sexual risk behavior. PMID:25688731
Shami, Vanessa M; Mahajan, Anshu; Sundaram, Vinay; Davis, Eric M; Loch, Michelle M; Kahaleh, Michel
2008-11-01
Accurate preoperative staging of pancreatic cancer (Pca) is crucial to direct management. There is a perception that endoscopic ultrasound (EUS) staging should be performed before biliary decompression because of artifact caused by self-expandable metal stents (SEMS). Our aim is to determine whether placement of SEMS affects the staging of Pca. Fifty-five patients (35 men; mean age, 67 years) with newly diagnosed Pca staged in the last 5 years and captured prospectively were divided into 2 groups matched by age, sex, and final staging. The staging accuracy of EUS in patients who had a SEMS (n = 28) was compared with patients without a SEMS (n = 27). The gold standard was surgical pathology, or cytologic confirmation of metastatic disease. Multivariate analysis was effected on age, sex, presence of SEMS, and presence of metastasis to assess prediction of staging inaccuracy. Endoscopic ultrasound correctly staged 14 (52%) of 27 patients in the no-SEMS group and 13 (46%) of 28 in the SEMS group. Logistic regression analysis identified only metastasis as a predictor of inaccuracy in EUS staging. Endoscopic ultrasound staging of Pca does not seem to be affected by the presence of a SEMS. The major reason for misstaging in both groups was failure to detect metastatic disease.
Træen, Bente; Hald, Gert Martin; Noor, Syed W.; Iantaffi, Alex; Grey, Jeremy; Rosser, B. R. Simon
2014-01-01
This study tests the following three hypotheses: 1) there is a direct association between consumption of sexually explicit media (SEM) depicting non-condom use and STI-related sexual risk behavior among men who have sex with men (MSM), 2) The association between SEM consumption and STI-related sexual risk behavior is mediated by men’s sexual self-esteem, and 3) the relationship between SEM consumption and sexual risk behavior is mediated by condom use self-efficacy. A cross-sectional, Internet-based survey on exposure to SEM and sexual behavior of 1,391 MSM in the USA was conducted in 2011. The results confirmed hypothesis 1 and 3 while hypothesis 2 was rejected. Accordingly, a significant association between the use of SEM picturing condom use and STI related sexual risk behavior among MSM was found. Likewise, we found that the association between the use of SEM and sexual risk behavior was mediated by condom use self-efficacy in an indirect path. However, SEM did not influence sexual risk behavior via sexual self-esteem. To promote STI prevention, the actors in SEM may be used as role models in managing condom use in sexual contexts. PMID:24904709
Kownacki, Andrzej; Woznicka, Olga; Szarek-Gwiazda, Ewa; Michailova, Paraskeva; Czaplicka, Anna
2017-02-27
In this paper, a study of the morphology of the pupa and male imago of Glyptotendipes (G.) glaucus (Meigen 1818) was carried out, with the aid of a scanning electron microscope (SEM). The SEM provided additional valuable information on the morphology of the species. Adult male head, antenna, wing, leg, abdomen, hypopygium, pupal cephalothorax and abdomen were examined. It is emphasized that SEM was not often used in Chironomidae studies. The present results confirm SEM as a suitable approach in carrying out morphological and taxonomical descriptions of Chironomidae species.
Dependently Typed Programming with Domain-Specific Logics
2011-02-28
van den Berg and Garner, 2010; Voevodsky, 2010). This work promises a new class of proof assistants that intrinsically support proof irrelevance, equal...InΣ (neuA⇐ neu ⊗ sem) neut : InΣ (semA⇐ neu) slam : InΣ (semA⇐ (∀6 neuC (sem ⊃ sem))) reifyenv : Vars Vars Type reifyenv Ψe Ψs = ([Ψs ] * (neuC...ϕ) = lam · reify (Ψe, , expC) (Ψs, , neuC) σ’ (ϕ [neuC ] ( neut · (. i0))) where σ’ : (reifyenv (Ψe, , expC) (Ψs, , neuC)) σ’ i0 = i0 σ’ (iS x) = iS
Suzuki, Kazuhiko; Oho, Eisaku
2013-01-01
Quality of a scanning electron microscopy (SEM) image is strongly influenced by noise. This is a fundamental drawback of the SEM instrument. Complex hysteresis smoothing (CHS) has been previously developed for noise removal of SEM images. This noise removal is performed by monitoring and processing properly the amplitude of the SEM signal. As it stands now, CHS may not be so utilized, though it has several advantages for SEM. For example, the resolution of image processed by CHS is basically equal to that of the original image. In order to find wide application of the CHS method in microscopy, the feature of CHS, which has not been so clarified until now is evaluated correctly. As the application of the result obtained by the feature evaluation, cursor width (CW), which is the sole processing parameter of CHS, is determined more properly using standard deviation of noise Nσ. In addition, disadvantage that CHS cannot remove the noise with excessively large amplitude is improved by a certain postprocessing. CHS is successfully applicable to SEM images with various noise amplitudes. © Wiley Periodicals, Inc.
Justino, Priscilla F C; Melo, Luis F M; Nogueira, Andre F; Costa, Jose V G; Silva, Luara M N; Santos, Cecila M; Mendes, Walber O; Costa, Marina R; Franco, Alvaro X; Lima, Aldo A; Ribeiro, Ronaldo A; Souza, Marcellus H L P; Soares, Pedro M G
2014-05-01
Intestinal mucositis is an important toxic side effect of 5-fluorouracil (5-FU) treatment. Saccharomyces boulardii is known to protect from intestinal injury via an effect on the gastrointestinal microbiota. The objective of the present study was to evaluate the effect of S. boulardii on intestinal mucositis induced by 5-FU in a murine model. Mice were divided into saline, saline (control)+5-FU or 5-FU+S. boulardii (16 × 10⁹ colony-forming units/kg) treatment groups, and the jejunum and ileum were removed after killing of mice for the evaluation of histopathology, myeloperoxidase (MPO) activity, and non-protein sulfhydryl group (mainly reduced glutathione; GSH), nitrite and cytokine concentrations. To determine gastric emptying, phenol red was administered orally, mice were killed 20 min after administration, and the absorbance of samples collected from the mice was measured by spectrophotometry. Intestinal permeability was measured by the urinary excretion rate of lactulose and mannitol following oral administration. S. boulardii significantly reversed the histopathological changes in intestinal mucositis induced by 5-FU and reduced the inflammatory parameters: neutrophil infiltration (control 1·73 (SEM 0·37) ultrastructural MPO (UMPO)/mg, 5-FU 7·37 (SEM 1·77) UMPO/mg and 5-FU+S. boulardii 4·15 (SEM 0·73) UMPO/mg); nitrite concentration (control 37·00 (SEM 2·39) μm, 5-FU 59·04 (SEM 11·41) μm and 5-FU+S. boulardii 37·90 (SEM 5·78) μm); GSH concentration (control 477·60 (SEM 25·25) μg/mg, 5-FU 270·90 (SEM 38·50) μg/mg and 5-FU+S. boulardii 514·00 (SEM 38·64) μg/mg). Treatment with S. Boulardii significantly reduced the concentrations of TNF-α and IL-1β by 48·92 and 32·21 % in the jejunum and 38·92 and 61·79 % in the ileum. In addition, S. boulardii decreased the concentrations of chemokine (C-X-C motif) ligand 1 by 5-fold in the jejunum and 3-fold in the ileum. Interestingly, S. boulardii reduced the delay in gastric emptying (control 25·21 (SEM 2·55) %, 5-FU 54·91 (SEM 3·43) % and 5-FU+S. boulardii 31·38 (SEM 2·80) %) and induced the recovery of intestinal permeability (lactulose:mannitol ratio: control 0·52 (SEM 0·03), 5-FU 1·38 (SEM 0·24) and 5-FU+S. boulardii 0·62 (SEM 0·03)). In conclusion, S. boulardii reduces the inflammation and dysfunction of the gastrointestinal tract in intestinal mucositis induced by 5-FU.
Lee, Jong Jin; Hyun, Jong Jin; Choe, Jung Wan; Lee, Dong-Won; Kim, Seung Young; Jung, Sung Woo; Jung, Young Kul; Koo, Ja Seol; Yim, Hyung Joon; Lee, Sang Woo
2017-11-01
Endoscopic stenting for combined malignant biliary and duodenal obstruction is technically demanding. However, this procedure can be facilitated when there is guidance from previously inserted stent or PTBD tube. This study aimed to evaluate the feasibility and clinical success rate of endoscopic placement of biliary self-expandable metal stent (SEMS) through duodenal SEMS in patients with combined biliary and duodenal obstruction due to inoperable or metastatic periampullary malignancy. A total of 12 patients with combined malignant biliary and duodenal stricture underwent insertion of biliary SEMS through the mesh of specialized duodenal SEMS from July 2012 to October 2016. Technical and clinical success rate, adverse events and survival after completion of SEMS insertion were evaluated. The duodenal strictures were located in the first portion of the duodenum in four patients (Type I), in the second portion in three patients (Type II), and in the third portion in five patients (Type III). Technical success rate of combined metallic stenting was 91.7%. Insertion of biliary SEMS was guided by previously inserted biliary SEMS in nine patients, plastic stent in one patient, and PTBD in two patients. Clinical success rate was 90.9%. There were no early adverse events after the procedure. Mean survival period after combined metallic stenting was 91.9 days (range: 15-245 days). Endoscopic placement of biliary SEMS through duodenal SEMS is feasible with high success rates and relatively easy when there is guidance. This method can be a good alternative for palliation in patients with combined biliary and duodenal obstruction.
NASA Astrophysics Data System (ADS)
Aimran, Ahmad Nazim; Ahmad, Sabri; Afthanorhan, Asyraf; Awang, Zainudin
2017-05-01
Structural equation modeling (SEM) is the second generation statistical analysis technique developed for analyzing the inter-relationships among multiple variables in a model. Previous studies have shown that there seemed to be at least an implicit agreement about the factors that should drive the choice between covariance-based structural equation modeling (CB-SEM) and partial least square path modeling (PLS-PM). PLS-PM appears to be the preferred method by previous scholars because of its less stringent assumption and the need to avoid the perceived difficulties in CB-SEM. Along with this issue has been the increasing debate among researchers on the use of CB-SEM and PLS-PM in studies. The present study intends to assess the performance of CB-SEM and PLS-PM as a confirmatory study in which the findings will contribute to the body of knowledge of SEM. Maximum likelihood (ML) was chosen as the estimator for CB-SEM and was expected to be more powerful than PLS-PM. Based on the balanced experimental design, the multivariate normal data with specified population parameter and sample sizes were generated using Pro-Active Monte Carlo simulation, and the data were analyzed using AMOS for CB-SEM and SmartPLS for PLS-PM. Comparative Bias Index (CBI), construct relationship, average variance extracted (AVE), composite reliability (CR), and Fornell-Larcker criterion were used to study the consequence of each estimator. The findings conclude that CB-SEM performed notably better than PLS-PM in estimation for large sample size (100 and above), particularly in terms of estimations accuracy and consistency.
Nondestructive SEM for surface and subsurface wafer imaging
NASA Technical Reports Server (NTRS)
Propst, Roy H.; Bagnell, C. Robert; Cole, Edward I., Jr.; Davies, Brian G.; Dibianca, Frank A.; Johnson, Darryl G.; Oxford, William V.; Smith, Craig A.
1987-01-01
The scanning electron microscope (SEM) is considered as a tool for both failure analysis as well as device characterization. A survey is made of various operational SEM modes and their applicability to image processing methods on semiconductor devices.
Antoni, Rona; Johnston, Kelly L; Collins, Adam L; Robertson, M Denise
2018-03-01
The intermittent energy restriction (IER) approach to weight loss involves short periods of substantial (>70 %) energy restriction (ER) interspersed with normal eating. Studies to date comparing IER to continuous energy restriction (CER) have predominantly measured fasting indices of cardiometabolic risk. This study aimed to compare the effects of IER and CER on postprandial glucose and lipid metabolism following matched weight loss. In all, twenty-seven (thirteen male) overweight/obese participants (46 (sem 3) years, 30·1 (sem 1·0) kg/m2) who were randomised to either an IER intervention (2638 kJ for 2 d/week with an overall ER of 22 (sem 0·3) %, n 15) or a CER intervention (2510 kJ below requirements with overall ER of 23 (sem 0·8) %) completed the study. Postprandial responses to a test meal (over 360 min) and changes in anthropometry (fat mass, fat-free mass, circumferences) were assessed at baseline and upon attainment of 5 % weight loss, following a 7-d period of weight stabilisation. The study found no statistically significant difference in the time to attain a 5 % weight loss between groups (median 59 d (interquartile range (IQR) 41-80) and 73 d (IQR 48-128), respectively, P=0·246), or in body composition (P≥0·437). For postprandial measures, neither diet significantly altered glycaemia (P=0·266), whereas insulinaemia was reduced comparatively (P=0·903). The reduction in C-peptide tended (P=0·057) to be greater following IER (309 128 (sem23 268) to 247781 (sem20 709) pmol×360 min/l) v. CER (297 204 (sem25 112) to 301 655 (sem32 714) pmol×360 min/l). The relative reduction in TAG responses was greater (P=0·045) following IER (106 (sem30) to 68 (sem 15) mmol×360 min/l) compared with CER (117 (sem 43) to 130 (sem 31) mmol×360 min/l). In conclusion, these preliminary findings highlight underlying differences between IER and CER, including a superiority of IER in reducing postprandial lipaemia, which now warrant targeted mechanistic evaluation within larger study cohorts.
Three dimensional profile measurement using multi-channel detector MVM-SEM
NASA Astrophysics Data System (ADS)
Yoshikawa, Makoto; Harada, Sumito; Ito, Keisuke; Murakawa, Tsutomu; Shida, Soichi; Matsumoto, Jun; Nakamura, Takayuki
2014-07-01
In next generation lithography (NGL) for the 1x nm node and beyond, the three dimensional (3D) shape measurements such as side wall angle (SWA) and height of feature on photomask become more critical for the process control. Until today, AFM (Atomic Force Microscope), X-SEM (cross-section Scanning Electron Microscope) and TEM (Transmission Electron Microscope) tools are normally used for 3D measurements, however, these techniques require time-consuming preparation and observation. And both X-SEM and TEM are destructive measurement techniques. This paper presents a technology for quick and non-destructive 3D shape analysis using multi-channel detector MVM-SEM (Multi Vision Metrology SEM), and also reports its accuracy and precision.
Wieman, S R; Didkovsky, L V; Judge, D L
The Solar EUV Monitor (SEM) onboard SOHO has measured absolute extreme ultraviolet (EUV) and soft X-ray solar irradiance nearly continuously since January 1996. The EUV Variability Experiment (EVE) on SDO, in operation since April of 2010, measures solar irradiance in a wide spectral range that encompasses the band passes (26 - 34 nm and 0.1 - 50 nm) measured by SOHO/SEM. However, throughout the mission overlap, irradiance values from these two instruments have differed by more than the combined stated uncertainties of the measurements. In an effort to identify the sources of these differences and eliminate them, we investigate in this work the effect of reprocessing the SEM data using a more accurate SEM response function (obtained from synchrotron measurements with a SEM sounding-rocket clone instrument taken after SOHO was already in orbit) and time-dependent, measured solar spectral distributions - i.e ., solar reference spectra that were unavailable prior to the launch of the SDO. We find that recalculating the SEM data with these improved parameters reduces mean differences with the EVE measurements from about 20 % to less than 5 % in the 26 - 34 nm band, and from about 35 % to about 15 % for irradiances in the 0.1 - 7 nm band extracted from the SEM 0.1 - 50 nm channel.
NASA Astrophysics Data System (ADS)
Jusman, Yessi; Ng, Siew-Cheok; Hasikin, Khairunnisa; Kurnia, Rahmadi; Osman, Noor Azuan Bin Abu; Teoh, Kean Hooi
2016-10-01
The capability of field emission scanning electron microscopy and energy dispersive x-ray spectroscopy (FE-SEM/EDX) to scan material structures at the microlevel and characterize the material with its elemental properties has inspired this research, which has developed an FE-SEM/EDX-based cervical cancer screening system. The developed computer-aided screening system consisted of two parts, which were the automatic features of extraction and classification. For the automatic features extraction algorithm, the image and spectra of cervical cells features extraction algorithm for extracting the discriminant features of FE-SEM/EDX data was introduced. The system automatically extracted two types of features based on FE-SEM/EDX images and FE-SEM/EDX spectra. Textural features were extracted from the FE-SEM/EDX image using a gray level co-occurrence matrix technique, while the FE-SEM/EDX spectra features were calculated based on peak heights and corrected area under the peaks using an algorithm. A discriminant analysis technique was employed to predict the cervical precancerous stage into three classes: normal, low-grade intraepithelial squamous lesion (LSIL), and high-grade intraepithelial squamous lesion (HSIL). The capability of the developed screening system was tested using 700 FE-SEM/EDX spectra (300 normal, 200 LSIL, and 200 HSIL cases). The accuracy, sensitivity, and specificity performances were 98.2%, 99.0%, and 98.0%, respectively.
Koga, Daisuke; Kusumi, Satoshi; Shodo, Ryusuke; Dan, Yukari; Ushiki, Tatsuo
2015-12-01
In this study, we introduce scanning electron microscopy (SEM) of semithin resin sections. In this technique, semithin sections were adhered on glass slides, stained with both uranyl acetate and lead citrate, and observed with a backscattered electron detector at a low accelerating voltage. As the specimens are stained in the same manner as conventional transmission electron microscopy (TEM), the contrast of SEM images of semithin sections was similar to TEM images of ultrathin sections. Using this technique, wide areas of semithin sections were also observed by SEM, without the obstruction of grids, which was inevitable for traditional TEM. This study also applied semithin section SEM to correlative light and electron microscopy. Correlative immunofluorescence microscopy and immune-SEM were performed in semithin sections of LR white resin-embedded specimens using a FluoroNanogold-labeled secondary antibody. Because LR white resin is hydrophilic and electron stable, this resin is suitable for immunostaining and SEM observation. Using correlative microscopy, the precise localization of the primary antibody was demonstrated by fluorescence microscopy and SEM. This method has great potential for studies examining the precise localization of molecules, including Golgi- and ER-associated proteins, in correlation with LM and SEM. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Lee, Tae Hoon; Jang, Bong Seok; Jung, Min Kyo; Pack, Chan Gi; Choi, Jun-Ho; Park, Do Hyun
2016-01-01
To reduce tissue or tumor ingrowth, covered self-expandable metal stents (SEMSs) have been developed. The effectiveness of covered SEMSs may be attenuated by sludge or stone formation or by stent clogging due to the formation of biofilm on the covering membrane. In this study, we tested the hypothesis that a silicone membrane containing silver particles (Ag-P) would prevent sludge and biofilm formation on the covered SEMS. In vitro, the Ag-P-integrated silicone polymer-covered membrane exhibited sustained antibacterial activity, and there was no definite release of silver ions from the Ag-P-integrated silicone polymer membrane at any time point. Using a porcine stent model, in vivo analysis demonstrated that the Ag-P-integrated silicone polymer-covered SEMS reduced the thickness of the biofilm and the quantity of sludge formed, compared with a conventional silicone-covered SEMS. In vivo, the release of silver ions from an Ag-P-integrated silicone polymer-covered SEMS was not detected in porcine serum. The Ag-P-integrated silicone polymer-covered SEMS also resulted in significantly less stent-related bile duct and subepithelium tissue inflammation than a conventional silicone polymer-covered SEMS. Therefore, the Ag-P-integrated silicone polymer-covered SEMS reduced sludge and biofilm formation and stent-induced pathological changes in tissue. This novel SEMS may prolong the stent patency in clinical application. PMID:27739486
Focused ion beam (FIB)/scanning electron microscopy (SEM) in tissue structural research.
Leser, Vladka; Milani, Marziale; Tatti, Francesco; Tkalec, Ziva Pipan; Strus, Jasna; Drobne, Damjana
2010-10-01
The focused ion beam (FIB) and scanning electron microscope (SEM) are commonly used in material sciences for imaging and analysis of materials. Over the last decade, the combined FIB/SEM system has proven to be also applicable in the life sciences. We have examined the potential of the focused ion beam/scanning electron microscope system for the investigation of biological tissues of the model organism Porcellio scaber (Crustacea: Isopoda). Tissue from digestive glands was prepared as for conventional SEM or as for transmission electron microscopy (TEM). The samples were transferred into FIB/SEM for FIB milling and an imaging operation. FIB-milled regions were secondary electron imaged, back-scattered electron imaged, or energy dispersive X-ray (EDX) analyzed. Our results demonstrated that FIB/SEM enables simultaneous investigation of sample gross morphology, cell surface characteristics, and subsurface structures. The same FIB-exposed regions were analyzed by EDX to provide basic compositional data. When samples were prepared as for TEM, the information obtained with FIB/SEM is comparable, though at limited magnification, to that obtained from TEM. A combination of imaging, micro-manipulation, and compositional analysis appears of particular interest in the investigation of epithelial tissues, which are subjected to various endogenous and exogenous conditions affecting their structure and function. The FIB/SEM is a promising tool for an overall examination of epithelial tissue under normal, stressed, or pathological conditions.
Lee, Tae Hoon; Jang, Bong Seok; Jung, Min Kyo; Pack, Chan Gi; Choi, Jun-Ho; Park, Do Hyun
2016-10-14
To reduce tissue or tumor ingrowth, covered self-expandable metal stents (SEMSs) have been developed. The effectiveness of covered SEMSs may be attenuated by sludge or stone formation or by stent clogging due to the formation of biofilm on the covering membrane. In this study, we tested the hypothesis that a silicone membrane containing silver particles (Ag-P) would prevent sludge and biofilm formation on the covered SEMS. In vitro, the Ag-P-integrated silicone polymer-covered membrane exhibited sustained antibacterial activity, and there was no definite release of silver ions from the Ag-P-integrated silicone polymer membrane at any time point. Using a porcine stent model, in vivo analysis demonstrated that the Ag-P-integrated silicone polymer-covered SEMS reduced the thickness of the biofilm and the quantity of sludge formed, compared with a conventional silicone-covered SEMS. In vivo, the release of silver ions from an Ag-P-integrated silicone polymer-covered SEMS was not detected in porcine serum. The Ag-P-integrated silicone polymer-covered SEMS also resulted in significantly less stent-related bile duct and subepithelium tissue inflammation than a conventional silicone polymer-covered SEMS. Therefore, the Ag-P-integrated silicone polymer-covered SEMS reduced sludge and biofilm formation and stent-induced pathological changes in tissue. This novel SEMS may prolong the stent patency in clinical application.
Wu, Honghan; Toti, Giulia; Morley, Katherine I; Ibrahim, Zina M; Folarin, Amos; Jackson, Richard; Kartoglu, Ismail; Agrawal, Asha; Stringer, Clive; Gale, Darren; Gorrell, Genevieve; Roberts, Angus; Broadbent, Matthew; Stewart, Robert; Dobson, Richard J B
2018-05-01
Unlocking the data contained within both structured and unstructured components of electronic health records (EHRs) has the potential to provide a step change in data available for secondary research use, generation of actionable medical insights, hospital management, and trial recruitment. To achieve this, we implemented SemEHR, an open source semantic search and analytics tool for EHRs. SemEHR implements a generic information extraction (IE) and retrieval infrastructure by identifying contextualized mentions of a wide range of biomedical concepts within EHRs. Natural language processing annotations are further assembled at the patient level and extended with EHR-specific knowledge to generate a timeline for each patient. The semantic data are serviced via ontology-based search and analytics interfaces. SemEHR has been deployed at a number of UK hospitals, including the Clinical Record Interactive Search, an anonymized replica of the EHR of the UK South London and Maudsley National Health Service Foundation Trust, one of Europe's largest providers of mental health services. In 2 Clinical Record Interactive Search-based studies, SemEHR achieved 93% (hepatitis C) and 99% (HIV) F-measure results in identifying true positive patients. At King's College Hospital in London, as part of the CogStack program (github.com/cogstack), SemEHR is being used to recruit patients into the UK Department of Health 100 000 Genomes Project (genomicsengland.co.uk). The validation study suggests that the tool can validate previously recruited cases and is very fast at searching phenotypes; time for recruitment criteria checking was reduced from days to minutes. Validated on open intensive care EHR data, Medical Information Mart for Intensive Care III, the vital signs extracted by SemEHR can achieve around 97% accuracy. Results from the multiple case studies demonstrate SemEHR's efficiency: weeks or months of work can be done within hours or minutes in some cases. SemEHR provides a more comprehensive view of patients, bringing in more and unexpected insight compared to study-oriented bespoke IE systems. SemEHR is open source, available at https://github.com/CogStack/SemEHR.
The Truth about Scores Children Achieve on Tests.
ERIC Educational Resources Information Center
Brown, Jonathan R.
1989-01-01
The importance of using the standard error of measurement (SEm) in determining reliability in test scores is emphasized. The SEm is compared to the hypothetical true score for standardized tests, and procedures for calculation of the SEm are explained. (JDD)
Carbon Stocks and Fluxes in Tropical Lowland Dipterocarp Rainforests in Sabah, Malaysian Borneo
Saner, Philippe; Loh, Yen Yee; Ong, Robert C.; Hector, Andy
2012-01-01
Deforestation in the tropics is an important source of carbon C release to the atmosphere. To provide a sound scientific base for efforts taken to reduce emissions from deforestation and degradation (REDD+) good estimates of C stocks and fluxes are important. We present components of the C balance for selectively logged lowland tropical dipterocarp rainforest in the Malua Forest Reserve of Sabah, Malaysian Borneo. Total organic C in this area was 167.9 Mg C ha−1±3.8 (SD), including: Total aboveground (TAGC: 55%; 91.9 Mg C ha−1±2.9 SEM) and belowground carbon in trees (TBGC: 10%; 16.5 Mg C ha−1±0.5 SEM), deadwood (8%; 13.2 Mg C ha−1±3.5 SEM) and soil organic matter (SOM: 24%; 39.6 Mg C ha−1±0.9 SEM), understory vegetation (3%; 5.1 Mg C ha−1±1.7 SEM), standing litter (<1%; 0.7 Mg C ha−1±0.1 SEM) and fine root biomass (<1%; 0.9 Mg C ha−1±0.1 SEM). Fluxes included litterfall, a proxy for leaf net primary productivity (4.9 Mg C ha−1 yr−1±0.1 SEM), and soil respiration, a measure for heterotrophic ecosystem respiration (28.6 Mg C ha−1 yr−1±1.2 SEM). The missing estimates necessary to close the C balance are wood net primary productivity and autotrophic respiration. Twenty-two years after logging TAGC stocks were 28% lower compared to unlogged forest (128 Mg C ha−1±13.4 SEM); a combined weighted average mean reduction due to selective logging of −57.8 Mg C ha−1 (with 95% CI −75.5 to −40.2). Based on the findings we conclude that selective logging decreased the dipterocarp stock by 55–66%. Silvicultural treatments may have the potential to accelerate the recovery of dipterocarp C stocks to pre-logging levels. PMID:22235319
Kuwajima, Masaaki; Mendenhall, John M.; Lindsey, Laurence F.; Harris, Kristen M.
2013-01-01
Transmission-mode scanning electron microscopy (tSEM) on a field emission SEM platform was developed for efficient and cost-effective imaging of circuit-scale volumes from brain at nanoscale resolution. Image area was maximized while optimizing the resolution and dynamic range necessary for discriminating key subcellular structures, such as small axonal, dendritic and glial processes, synapses, smooth endoplasmic reticulum, vesicles, microtubules, polyribosomes, and endosomes which are critical for neuronal function. Individual image fields from the tSEM system were up to 4,295 µm2 (65.54 µm per side) at 2 nm pixel size, contrasting with image fields from a modern transmission electron microscope (TEM) system, which were only 66.59 µm2 (8.160 µm per side) at the same pixel size. The tSEM produced outstanding images and had reduced distortion and drift relative to TEM. Automated stage and scan control in tSEM easily provided unattended serial section imaging and montaging. Lens and scan properties on both TEM and SEM platforms revealed no significant nonlinear distortions within a central field of ∼100 µm2 and produced near-perfect image registration across serial sections using the computational elastic alignment tool in Fiji/TrakEM2 software, and reliable geometric measurements from RECONSTRUCT™ or Fiji/TrakEM2 software. Axial resolution limits the analysis of small structures contained within a section (∼45 nm). Since this new tSEM is non-destructive, objects within a section can be explored at finer axial resolution in TEM tomography with current methods. Future development of tSEM tomography promises thinner axial resolution producing nearly isotropic voxels and should provide within-section analyses of structures without changing platforms. Brain was the test system given our interest in synaptic connectivity and plasticity; however, the new tSEM system is readily applicable to other biological systems. PMID:23555711
Romero-Franco, Natalia; Montaño-Munuera, Juan Antonio; Fernández-Domínguez, Juan Carlos; Jiménez-Reyes, Pedro
2017-12-18
New methods are being validated to easily evaluate the knee joint position sense (JPS) due to its role in sports movement and the risk of injury. However, no studies to date have considered the open kinetic chain (OKC) technique, despite the biomechanical differences compared to closed kinetic chain movements. To analyze the validity and reliability of a digital inclinometer to measure the knee JPS in the OKC movement. The validity, inter-tester and intra-tester reliability of a digital inclinometer for measuring knee JPS were evaluated. Sports research laboratory. Eighteen athletes (11 males and 7 females; 28.4 ± 6.6 years; 71.9 ± 14.0 kg; 1.77 ± 0.09 m; 22.8 ± 3.2 kg/m 2 ) voluntary participated in this study. Absolute angular error (AAE), relative angular error (RAE) and variable angular error (VAE) of knee JPS in an OKC. Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed excellent validity of the inclinometer to obtain proprioceptive errors compared to the video analysis in JPS tasks (AAE: ICC = 0.981, SEM = 0.08; RAE: ICC = 0.974, SEM = 0.12; VAE: ICC = 0.973, SEM = 0.07). Inter-tester reliability was also excellent for all the proprioceptive errors (AAE: ICC = 0.967, SEM = 0.04; RAE: ICC = 0.974, SEM = 0.03; VAE: ICC = 0.939, SEM = 0.08). Similar results were obtained for intra-tester reliability (AAE: ICC = 0.861, SEM = 0.1; RAE: ICC = 0.894, SEM = 0.1; VAE: ICC = 0.700, SEM = 0.2). The digital inclinometer is a valid and reliable method to assess the knee JPS in OKC. Sport professionals may evaluate the knee JPS to monitor its deterioration during training or improvements throughout the rehabilitation process.
Kitessa, Soressa M; Young, Paul
2009-03-01
alpha-Linolenic acid (ALA; 18 : 3n-3) and stearidonic acid (SDA; 18 : 4n-3) are on the biosynthetic pathway of EPA (20 : 5n-3) and DHA (22 : 6n-3). The n-3 fatty acid in rapeseed oil is ALA while Echium oil contains both ALA and SDA. To determine the comparative efficacy of ALA- and SDA-rich oils in enriching broiler meat with n-3 PUFA, we offered diets supplemented with rapeseed oil (rapeseed group) or Echium oil (Echium group) for 35 d to two groups of chicks (age 21 d). There were no differences in carcass weight (2.20 (sem 0.06) v. 2.23 (sem 0.05) kg), boned, skinless thigh muscle (494 (sem 20.5) v. 507 (sem 16.7) g), boned, skinless breast muscle (553 (sem 13.4) v. 546 (sem 11.6) g) or organ weights (heart, liver and gizzard) between the two groups. The total intramuscular fat (IMF) percentage of thigh (8.0 (sem 0.64) v. 8.1 (sem 0.62) %) and breast muscles (2.3 (sem 0.24) v. 2.0 (sem 0.19) %) were also similar between the groups. In contrast, the concentrations of most of the individual n-3 fatty acids (ALA, SDA, EPA and docosapentaenoic acid) were all higher in the Echium than the rapeseed group (P < 0.05). However, differences in DHA concentrations were significant in breast but not thigh muscle IMF. The total n-3 yields/100 g serve thigh muscle were 265 and 676 mg for the rapeseed and Echium groups, respectively (P < 0.0001). The corresponding values for equivalent breast muscles were 70 and 137 mg, respectively (P < 0.01). We conclude that Echium oil is a better lipid supplement than rapeseed oil in changing the concentration and yield of n-3 fatty acids, except DHA, in broiler meat.
Shah, Tilak; Desai, Svetang; Haque, Mahfuzul; Dakik, Hassan; Fisher, Deborah
2013-01-01
Background Covered or uncovered self expandable metallic stents (SEMS) placed in patients with malignant biliary obstruction can occlude in 19–40%, but optimal management is unclear. Aim We sought to summarize current evidence regarding management of occluded SEMS in patients with malignant biliary obstruction. Methods Two investigators independently searched Pubmed, Embase, and Web of Science using pre-defined search criteria, and reviewed bibliographies of included studies. Data were independently abstracted by two investigators, and analyzed using RevMan. We compared strategies of second SEMS versus plastic stents with respect to the following outcomes: rate of second stent re-occlusion, duration of second stent patency, and survival. Results Ten retrospective studies met inclusion criteria for the systematic review. Management options described were placement of an uncovered SEMS (n=125), covered SEMS (n=106), plastic stent (n=135), percutaneous biliary drain (n=7), mechanical cleaning (n=18), or microwave coagulation (n=7). Relative risk of re-occlusion was not significantly different in patients with second SEMS compared to plastic stents (RR 1.24, 95% CI 0.92, 1.67, I2= 0, p 0.16). Duration of second stent patency was not significantly different between patients who received second SEMS versus plastic stents (weighted mean difference 0.46, 95% CI −0.30, 1.23, I2=83%). Survival was not significantly different among patients who received plastic stents versus SEMS (weighted mean difference −1.13, 95% CI −2.33, 0.07, I2 86%, p 0.07). Conclusions Among patients with malignant biliary obstruction and occluded SEMS, available evidence suggests a strategy of placing a plastic stent may be as effective as second SEMS. Limitations of these findings were that all studies were retrospective and heterogeneity between studies was detected for two of the outcomes. PMID:22732833
Nguyen, Huy Bang; Thai, Truc Quynh; Saitoh, Sei; Wu, Bao; Saitoh, Yurika; Shimo, Satoshi; Fujitani, Hiroshi; Otobe, Hirohide; Ohno, Nobuhiko
2016-01-01
Recent advances in serial block-face imaging using scanning electron microscopy (SEM) have enabled the rapid and efficient acquisition of 3-dimensional (3D) ultrastructural information from a large volume of biological specimens including brain tissues. However, volume imaging under SEM is often hampered by sample charging, and typically requires specific sample preparation to reduce charging and increase image contrast. In the present study, we introduced carbon-based conductive resins for 3D analyses of subcellular ultrastructures, using serial block-face SEM (SBF-SEM) to image samples. Conductive resins were produced by adding the carbon black filler, Ketjen black, to resins commonly used for electron microscopic observations of biological specimens. Carbon black mostly localized around tissues and did not penetrate cells, whereas the conductive resins significantly reduced the charging of samples during SBF-SEM imaging. When serial images were acquired, embedding into the conductive resins improved the resolution of images by facilitating the successful cutting of samples in SBF-SEM. These results suggest that improving the conductivities of resins with a carbon black filler is a simple and useful option for reducing charging and enhancing the resolution of images obtained for volume imaging with SEM. PMID:27020327
Typologies of sexually explicit media use among MSM: An application of latent class analysis
Erickson, Darin J.; Galos, Dylan L; Smolenski, Derek, J.; Iantaffi, Alex; Rosser, B.R. Simon
2014-01-01
The viewing of sexually explicit media (SEM) is widespread, especially among men, and research linking SEM viewing and sexual behavior has shown a variety of results, some positive (e.g., sexuality education) and some negative (e.g., poorer body image). These results might be due to limitations in measuring SEM consumption, particularly around typology. The goal of the current study was to examine potential patterns of SEM viewing activities. Using data from an online survey of men who have sex with men (MSM), we conducted latent class analyses of 15 SEM activities. Results suggested a three-class solution. The most prevalent class included over 60% of men and was characterized by viewing primarily safer-sex or conventional behaviors. The second class included 32% of men and had a similar albeit amplified pattern of viewing. The final class included just 7% of men and was marked by high levels of viewing of all activities, including fetish and kink. Compared to the conventional or safer-sex class, the other classes had lower internalized homonegativity, lower condom use self-efficacy, and higher SEM consumption or dose. Implications for HIV prevention, sexuality research and the SEM industry are discussed. PMID:25642301
Xing, Q.
2016-07-11
Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. Themore » electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energydispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. Finally, for an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly affect the usability of the SEM.« less
Information or resolution: Which is required from an SEM to study bulk inorganic materials?
Xing, Q
2016-11-01
Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. The electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energy-dispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. For an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly improve the usability of the SEM. SCANNING 38:864-879, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
Nelson, Kimberly M; Eaton, Lisa A; Gamarel, Kristi E
2017-05-01
Accumulating evidence suggests that viewing sexually explicit media (SEM; i.e., pornography) may be related to the sexual behaviors of men who have sex with men (MSM). Furthermore, stereotypical depictions of Black/African American MSM engaging in sexual risk behaviors in SEM may serve to normalize condomless sex, reinforce low peer norms around condom use, and facilitate HIV risk taking among Black/African American MSM. Despite this evidence, very little is known about the correlates of SEM consumption among Black/African American MSM, including HIV risk behaviors and their relation to preferences for viewing condomless sex in SEM. Participants were 653 HIV-seronegative Black-identified MSM ages 18-62 (M 33.58, SD 11.01) who completed a cross-sectional survey as a part of a HIV prevention trial in Atlanta, Georgia. Over three-quarters of the men (n = 514) reported a preference for condomless sex in SEM. In multivariate models, engaging in serodiscordant condomless sex was not significantly associated with preferences for condomless sex in SEM; however, men who self-identified as bisexual, engaged in transactional sex, and reported greater agreement with sexual risk cognitions (i.e., heat-of-the-moment thoughts about condom use) had significantly greater odds of reporting a preference for condomless sex in SEM. Study findings highlight the need for future research exploring the role of SEM in the sexual health of Black/African American MSM, including the extent to which SEM exposure alters norms and expectations about sexual behaviors among Black/African American MSM and how this might be addressed in HIV prevention programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xing, Q.
Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. Themore » electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energydispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. Finally, for an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly affect the usability of the SEM.« less
Automated CD-SEM recipe creation technology for mass production using CAD data
NASA Astrophysics Data System (ADS)
Kawahara, Toshikazu; Yoshida, Masamichi; Tanaka, Masashi; Ido, Sanyu; Nakano, Hiroyuki; Adachi, Naokaka; Abe, Yuichi; Nagatomo, Wataru
2011-03-01
Critical Dimension Scanning Electron Microscope (CD-SEM) recipe creation needs sample preparation necessary for matching pattern registration, and recipe creation on CD-SEM using the sample, which hinders the reduction in test production cost and time in semiconductor manufacturing factories. From the perspective of cost reduction and improvement of the test production efficiency, automated CD-SEM recipe creation without the sample preparation and the manual operation has been important in the production lines. For the automated CD-SEM recipe creation, we have introduced RecipeDirector (RD) that enables the recipe creation by using Computer-Aided Design (CAD) data and text data that includes measurement information. We have developed a system that automatically creates the CAD data and the text data necessary for the recipe creation on RD; and, for the elimination of the manual operation, we have enhanced RD so that all measurement information can be specified in the text data. As a result, we have established an automated CD-SEM recipe creation system without the sample preparation and the manual operation. For the introduction of the CD-SEM recipe creation system using RD to the production lines, the accuracy of the pattern matching was an issue. The shape of design templates for the matching created from the CAD data was different from that of SEM images in vision. Thus, a development of robust pattern matching algorithm that considers the shape difference was needed. The addition of image processing of the templates for the matching and shape processing of the CAD patterns in the lower layer has enabled the robust pattern matching. This paper describes the automated CD-SEM recipe creation technology for the production lines without the sample preparation and the manual operation using RD applied in Sony Semiconductor Kyusyu Corporation Kumamoto Technology Center (SCK Corporation Kumamoto TEC).
Haapamäki, C; Seppänen, H; Udd, M; Juuti, A; Halttunen, J; Kiviluoto, T; Sirén, J; Mustonen, H; Kylänpää, L
2015-06-01
The rainage (PBD) prior to pancreaticoduodenectomy (PD) is controversial. If PBD is required, large bore self-expandable metallic stents (SEMS) are thought to maintain better drainage and have fewer postoperative complications than plastic stents. The confirming evidence is scarce. The aim of the study was to compare outcomes of surgery in patients who underwent PBD with SEMS or plastic stents deployed at endoscopic retrograde cholangiopancreatography (ERCP). This is a retrospective study of 366 patients having had PD during 2000-2009. Preceding endoscopic PBD was performed in 191 patients and nine had had percutaneous transhepatic drainage (PTD). At the time of operation, 163 patients had a plastic stent and 28 had SEMS. Due to stent exchanges, 176 plastic stents and 29 SEMS were placed in all. The stent failure rate was 7.4% for plastic stents and 3.4% for SEMS (p = 0.697). A bilirubin level under 50 µmol/L was reached by 80% of the patients with plastic stents and by 61% of the patients with SEMS (p = 0.058). A postoperative infection complication and/or a pancreatic fistula was found in 26% while using plastic stents and in 25% using SEMS (p = 1.000). In unstented patients with biliary obstruction, the bile juice was sterile significantly more often than in endoscopically stented patients (100% vs 1%, p < 0.001). When the stented and unstented patients were compared regarding postoperative infection complications, there was no significant difference between the groups (p = 0.365). Plastic stents did not differ from SEMS regarding the stent failure rate, bilirubin level decrease, amount of bacteria in the bile juice, or postoperative complications when used for PBD. The significantly higher price of SEMS suggests their use in selected cases only. © The Finnish Surgical Society 2014.
Min, Chung Ki; Lee, Donghyoun; Jung, Kyung Uk; Lee, Sung Ryol; Kim, Hungdai; Chun, Ho-Kyung
2016-01-01
Purpose This study compared a subtotal colectomy to self-expandable metallic stent (SEMS) insertion as a bridge to surgery for patients with left colon-cancer obstruction. Methods Ninety-four consecutive patients with left colon-cancer obstruction underwent an emergency subtotal colectomy or elective SEMS insertion between January 2007 and August 2014. Using prospectively collected data, we performed a retrospective comparative analysis on an intention-to-treat basis. Results A subtotal colectomy and SEMS insertion were attempted in 24 and 70 patients, respectively. SEMS insertion technically failed in 5 patients (7.1%). The mean age and rate of obstruction in the descending colon were higher in the subtotal colectomy group than the SEMS group. Sex, underlying disease, American Society of Anesthesiologists physical status, and pathological stage showed no statistical difference. Laparoscopic surgery was performed more frequently in patients in the SEMS group (62 of 70, 88.6%) than in patients in the subtotal colectomy group (4 of 24, 16.7%). The overall rate of postoperative morbidity was higher in the SEMS group. No Clavien-Dindo grade III or IV complications occurred in the subtotal colectomy group, but 2 patients (2.9%) died from septic complications in the SEMS group. One patient (4.2%) in the subtotal colectomy group had synchronous cancer. The total hospital stay was shorter in the subtotal colectomy group. The median number of bowel movements in the subtotal colectomy group was twice per day at postoperative 3–6 months. Conclusion A subtotal colectomy for patients with obstructive left-colon cancer is a clinically and oncologically safer, 1-stage, surgical strategy compared to SEMS insertion as a bridge to surgery. PMID:28119864
Spectral-element Method for 3D Marine Controlled-source EM Modeling
NASA Astrophysics Data System (ADS)
Liu, L.; Yin, C.; Zhang, B., Sr.; Liu, Y.; Qiu, C.; Huang, X.; Zhu, J.
2017-12-01
As one of the predrill reservoir appraisal methods, marine controlled-source EM (MCSEM) has been widely used in mapping oil reservoirs to reduce risk of deep water exploration. With the technical development of MCSEM, the need for improved forward modeling tools has become evident. We introduce in this paper spectral element method (SEM) for 3D MCSEM modeling. It combines the flexibility of finite-element and high accuracy of spectral method. We use Galerkin weighted residual method to discretize the vector Helmholtz equation, where the curl-conforming Gauss-Lobatto-Chebyshev (GLC) polynomials are chosen as vector basis functions. As a kind of high-order complete orthogonal polynomials, the GLC have the characteristic of exponential convergence. This helps derive the matrix elements analytically and improves the modeling accuracy. Numerical 1D models using SEM with different orders show that SEM method delivers accurate results. With increasing SEM orders, the modeling accuracy improves largely. Further we compare our SEM with finite-difference (FD) method for a 3D reservoir model (Figure 1). The results show that SEM method is more effective than FD method. Only when the mesh is fine enough, can FD achieve the same accuracy of SEM. Therefore, to obtain the same precision, SEM greatly reduces the degrees of freedom and cost. Numerical experiments with different models (not shown here) demonstrate that SEM is an efficient and effective tool for MSCEM modeling that has significant advantages over traditional numerical methods.This research is supported by Key Program of National Natural Science Foundation of China (41530320), China Natural Science Foundation for Young Scientists (41404093), and Key National Research Project of China (2016YFC0303100, 2017YFC0601900).
Nelson, Kimberly M.; Eaton, Lisa A.; Gamarel, Kristi E.
2016-01-01
Accumulating evidence suggests that viewing sexually explicit media (SEM; i.e., pornography) may be related to the sexual behaviors of men who have sex with men (MSM). Furthermore, stereotypical depictions of Black/African American MSM engaging in sexual risk behaviors in SEM may serve to normalize condomless sex, reinforce low peer norms around condom use, and facilitate HIV risk-taking among Black/African American MSM. Despite this evidence, very little is known about the correlates of SEM consumption among Black/African American MSM, including HIV risk behaviors and their relation to preferences for viewing condomless sex in SEM. Participants were 653 HIV-seronegative Black-identified MSM ages 18 to 62 (M = 33.58, SD = 11.01) who completed a cross-sectional survey as a part of a HIV-prevention trial in Atlanta, Georgia. Over three-quarters of the men (n = 514) reported a preference for condomless sex in SEM. In multivariate models, engaging in serodiscordant condomless sex was not significantly associated with preferences for condomless sex in SEM; however, men who self-identified as bisexual, engaged in transactional sex, and reported greater agreement with sexual risk cognitions (i.e., heat of the moment thoughts about condom use) has significantly greater odds of reporting a preference for condomless sex in SEM. Study findings highlight the need for future research exploring the role of SEM in the sexual health of Black/African American MSM, including the extent to which SEM exposure alters norms and expectations about sexual behaviors among Black/African American MSM and how this might be addressed in HIV prevention programs. PMID:27987085
ERIC Educational Resources Information Center
Rodgers, Michelle; Zimar, Heather
2004-01-01
The "SEM Anthology" is a compilation of articles by more than 30 enrollment management professionals from a variety of institutions across the country. This collection, which has appeared in SEM Monthly over the past year, chronicles Strategic Enrollment Management efforts at campuses nationwide. The book illustrates the successes and challenges…
A methodology for extending domain coverage in SemRep.
Rosemblat, Graciela; Shin, Dongwook; Kilicoglu, Halil; Sneiderman, Charles; Rindflesch, Thomas C
2013-12-01
We describe a domain-independent methodology to extend SemRep coverage beyond the biomedical domain. SemRep, a natural language processing application originally designed for biomedical texts, uses the knowledge sources provided by the Unified Medical Language System (UMLS©). Ontological and terminological extensions to the system are needed in order to support other areas of knowledge. We extended SemRep's application by developing a semantic representation of a previously unsupported domain. This was achieved by adapting well-known ontology engineering phases and integrating them with the UMLS knowledge sources on which SemRep crucially depends. While the process to extend SemRep coverage has been successfully applied in earlier projects, this paper presents in detail the step-wise approach we followed and the mechanisms implemented. A case study in the field of medical informatics illustrates how the ontology engineering phases have been adapted for optimal integration with the UMLS. We provide qualitative and quantitative results, which indicate the validity and usefulness of our methodology. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
Edmunson, J.; Gaskin, J. A.; Danilatos, G.; Doloboff, I. J.; Effinger, M. R.; Harvey, R. P.; Jerman, G. A.; Klein-Schoder, R.; Mackie, W.; Magera, B.;
2016-01-01
The Miniaturized Variable Pressure Scanning Electron Microscope(MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Science (ROSES), will build upon previous miniaturized SEM designs for lunar and International Space Station (ISS) applications and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. By the end of the PICASSO work, a prototype of the primary proof-of-concept components (i.e., the electron gun, focusing optics and scanning system)will be assembled and preliminary testing in a Mars analog chamber at the Jet Propulsion Laboratory will be completed to partially fulfill Technology Readiness Level to 5 requirements for those components. The team plans to have Secondary Electron Imaging(SEI), Backscattered Electron (BSE) detection, and Energy Dispersive Spectroscopy (EDS) capabilities through the MVP-SEM.
Tang, Tang; Wei, Fangdi; Wang, Xu; Ma, Yujie; Song, Yueyue; Ma, Yunsu; Song, Quan; Xu, Guanhong; Cen, Yao; Hu, Qin
2018-02-15
A novel molecularly imprinted stir bar (MI-SB) for sorptive extraction of semicarbazide (SEM) was prepared in present paper. The coating of the stir bar was characterized by scanning electron microscopy, Fourier-transform infrared spectroscopy, dynamic adsorption and static adsorption tests. The saturated adsorption of MI-SB was about 4 times over that of non-imprinted stir bar (NI-SB). The selectivity of MI-SB for SEM was much better than NI-SB. A method to determine SEM was established by coupling MI-SB sorptive extraction with HPLC-UV. The liner range was 1-100ng/mL for SEM with a correlation coefficient of 0.9985. The limit of detection was about 0.59ng/mL, which was below the minimum required performance limit of SEM in meat products regulated by European Union. The method was applied to the determination of SEM in fish samples with satisfactory results. Copyright © 2018 Elsevier B.V. All rights reserved.
Wang, Ting; Li, Hong; Zhang, Qinglin; Tu, Shen; Yu, Caiyun; Qiu, Jiang
2010-04-01
Most Chinese characters are composed of a semantic radical on the left and a phonetic radical on the right. The semantic radical provides the semantic information; the phonetic radical provides information concerning the pronunciation of the whole character. The pseudo-characters in the study consisted of different sub-lexical parts of real Chinese characters and consequently they also had the semantic radical and the phonetic radical. But they were not readable and had no actual meaning. In order to investigate the spatiotemporal cortical activation patterns underlying the orthographic, phonological and semantic processing of Chinese characters, we used event-related brain potentials (ERPs) to explore the processing of Chinese characters and pseudo-characters when 14 healthy Chinese college students viewed the characters passively. Results showed that both Chinese characters and pseudo-characters elicited an evident negative potential peaking around 120 ms (N120), which appeared to reflect initial orthographic distinction and evaluation. Then, Chinese pseudo-characters elicited a more positive ERP deflection (P220) than did Chinese characters 200-250 ms after onset of the stimuli. It was similar to the recognition potential (RP) and might reflect the integration processes of phonological and semantic processing on the basis of early orthographic information. Dipole source analysis of the difference wave (pseudo-characters minus characters) indicated that a generator localized in the left temporal-occipital junction contributed to this effect, which was possibly related to phonological and perceptual-semantic information integration. Between 350-450 ms, a greater negativity (N360) in pseudo-characters as compared to characters was found over midline fronto-central scalp regions. Dipole analysis localized the generator of N360 in the right parahippocampal cortex. Therefore, the N360 might be an N400 component and reflect the higher-level semantic activation on the basis of orthographic, phonological and perceptual-semantic processing. La plupart des caractères chinois sont composés d'un radical sémantique à gauche et d'un radical phonétique à droite. Le radical sémantique peut fournir de l'information sémantique et le radical phonétique peut fournir de l'information concernant la prononciation du caractère entier. Les pseudo-caractères consistaient en différentes parties sous-lexicales des caractères chinois réels et, conséquemment, ils avaient aussi un radical sémantique et un radical phonétique. Mais ils ne pouvaient pas être lisibles et ils n'ont actuellement aucun sens. Afin d'étudier les patrons d'activation spatiotemporels corticaux sous-jacents aux traitements orthographique, phonologique et sémantique des caractères chinois, nous avons utilisé des Potentiels cérébraux reliés aux événements (PRE) pour explorer le traitement des caractères et des pseudo-caractères chinois auprès de 14 collégiens chinois visionnant les caractères passivement. Les résultats ont montré qu'à la fois les caractères et les pseudo-caractères chinois provoquaient un potentiel négatif évident atteignant un sommet autour de 120 ms (N120), ce qui apparaissait refléter la distinction et l'évaluation orthographiques initiales. Puis, les pseudo-caractères ont provoqué une déviation PRE plus positive (P220) que les caractères chinois entre 200 et 250 ms après l'apparition des stimuli. Ceci était similaire au PR (Potentiel de reconnaissance) et pouvait refléter les processus d'intégration des traitements phonologique et sémantique sur la base de l'information orthographique initiale. L'analyse dipôle de source de la différence de courbe (pseudo-caractères moins caractères) a indiqué qu'un générateur localisé dans la jonction temporo-occipitale gauche contribuait à cet effet, ce qui était possiblement relié à l'intégration de l'information phonologique et perceptuelle-sémantique. Entre 350 et 450 ms, une plus grande négativité (N360) fut observée pour les pseudo-caractères comparativement aux caractères des régions du scalp au-dessus des régions médianes fronto-centrales. L'analyse dipôle a localisé le générateur de N360 dans le cortex para-hippocampique droit. Ainsi, le N360 pourrait être une composante N400 et refléter une activation sémantique de haut niveau sur la base des traitements orthographique, phonologique et perceptuel-sémantique. La mayoría de los caracteres chinos están compuestos por un radical semántico a la izquierda y un radical fonético a la derecha. El radical semántico puede proporcionar información semántica y el radical fonético puede proporcionar información relacionada con la pronunciación del carácter entero. Los pseudo-caracteres consistieron en diferentes partes sub-léxicas de los caracteres reales chinos y como consecuencia, también tenían radicales semánticos y fonéticos. Pero éstos no se podían leer y tampoco tenían un significado real. Para investigar los patrones de la activación cortical espaciotemporal subyacentes de los procesamientos ortográfico, fonológico y semántico de los caracteres chinos, utilizamos potencial relacionado con eventos (ERPs) para explorar el procesamiento de caracteres chinos y pseudo-caracteres mientras que 14 sanos estudiantes chinos veían los caracteres de forma pasiva. Los resultados demostraron que ambos, caracteres y pseudo-caracteres chinos evocaban potenciales negativos con picos alrededor de los 120 ms (N120), lo cual parece reflejar distinción inicial ortográfica y evaluación. Además, los pseudo-caracteres chinos provocaban una desviación ERP más positiva (P220) en comparación con los caracteres chinos entre 200-250 ms después de la aparición de los estímulos. Esto fue parecido a RP (potenciales de reconocimiento) y puede reflejar un proceso de integración del procesamiento fonológico y semántico basado en la información ortográfica temprana. Un análisis dipolo de la fuente de la onda de diferencia (pseudo-caracteres menos caracteres) indicó que un generador localizado en el cruce temporal-occipital izquierdo contribuyó a este efecto, lo cual probablemente tuvo relación con la integración de la información fonológica y perceptivo-semántica. Se encontró mayor negatividad (N360) entre 350-450 ms, en pseudo-caracteres en comparación con los caracteres situada sobre las regiones de la línea media fronto-central craneal. Un análisis dipolo localizo un generador de N360 en el cortex parahipocampal derecho. Por tanto, el N360 podría ser un componente de N400 reflejando una activación semántica de más alto nivel basado en el procesamiento ortográfico, fonológico y perceptivo-semántico.
Inter-operator and inter-device agreement and reliability of the SEM Scanner.
Clendenin, Marta; Jaradeh, Kindah; Shamirian, Anasheh; Rhodes, Shannon L
2015-02-01
The SEM Scanner is a medical device designed for use by healthcare providers as part of pressure ulcer prevention programs. The objective of this study was to evaluate the inter-rater and inter-device agreement and reliability of the SEM Scanner. Thirty-one (31) volunteers free of pressure ulcers or broken skin at the sternum, sacrum, and heels were assessed with the SEM Scanner. Each of three operators utilized each of three devices to collect readings from four anatomical sites (sternum, sacrum, left and right heels) on each subject for a total of 108 readings per subject collected over approximately 30 min. For each combination of operator-device-anatomical site, three SEM readings were collected. Inter-operator and inter-device agreement and reliability were estimated. Over the course of this study, more than 3000 SEM Scanner readings were collected. Agreement between operators was good with mean differences ranging from -0.01 to 0.11. Inter-operator and inter-device reliability exceeded 0.80 at all anatomical sites assessed. The results of this study demonstrate the high reliability and good agreement of the SEM Scanner across different operators and different devices. Given the limitations of current methods to prevent and detect pressure ulcers, the SEM Scanner shows promise as an objective, reliable tool for assessing the presence or absence of pressure-induced tissue damage such as pressure ulcers. Copyright © 2015 Bruin Biometrics, LLC. Published by Elsevier Ltd.. All rights reserved.
Structural Equations and Causal Explanations: Some Challenges for Causal SEM
ERIC Educational Resources Information Center
Markus, Keith A.
2010-01-01
One common application of structural equation modeling (SEM) involves expressing and empirically investigating causal explanations. Nonetheless, several aspects of causal explanation that have an impact on behavioral science methodology remain poorly understood. It remains unclear whether applications of SEM should attempt to provide complete…
Amthauer, Camila; Cunha, Maria Luzia Chollopetz da
2016-08-29
to characterize the care services performed through risk rating by the Manchester Triage System, identifying demographics (age, gender), main flowcharts, discriminators and outcomes in pediatric emergency. cross-sectional quantitative study. Data on risk classification were obtained through a search of computerized registration data from medical records of patients treated in the pediatric emergency within one year. Descriptive statistics with absolute and relative frequencies was used for the analysis. 10,921 visits were conducted in the pediatric emergency, mostly male (54.4%), aged between 29 days and two years (44.5%). There was a prevalence of the urgent risk category (43.6%). The main flowchart used in the care was worried parents (22.4%) and the most prevalent discriminator was recent event (15.3%). The hospitalization outcome occurred in 10.4% of care performed in the pediatric emergency, however 61.8% of care needed to stay under observation and / or being under the health team care in the pediatric emergency. worried parents was the main flowchart used and recent events the most prevalent discriminator, comprising the hospitalization outcomes and permanency in observation in the pediatric emergency before discharge from the hospital. caracterizar os atendimentos realizados por meio da classificação de risco pelo Sistema de Triagem de Manchester, identificando dados demográficos (idade, sexo), principais fluxogramas, discriminadores e desfechos na emergência pediátrica. estudo quantitativo transversal. Os dados referentes à classificação de risco foram obtidos por meio de uma pesquisa ao registro informatizado de dados dos prontuários dos pacientes atendidos na emergência pediátrica no período de um ano. Para análise foi utilizada estatística descritiva com frequências absolutas e relativas. foram realizados 10.921 atendimentos na emergência pediátrica, em sua maioria do sexo masculino (54,4%), com idade entre 29 dias e dois anos (44,5%). Houve prevalência da categoria de risco urgente (43,6%). O principal fluxograma utilizado nos atendimentos foi pais preocupados (22,4%) e o discriminador mais prevalente foi evento recente (15,3%). O desfecho de internação hospitalar ocorreu em 10,4% dos atendimentos realizados na emergência pediátrica, entretanto 61,8% dos atendimentos necessitaram permanecer em observação e/ou ficar sob os cuidados da equipe de saúde na emergência pediátrica. pais preocupados foi o principal fluxograma utilizado e evento recente o discriminador mais prevalente, constando-se os desfechos de hospitalização e de permanencia em observação na emergência pediátrica, antes da alta para o domicílio. caracterizar la atención recibida por calificación de riesgo por el sistema de triaje de Manchester, identificando los datos demográficos (edad, sexo), principales organigramas, discriminadores y los resultados en la emergencia pediátrica. estudio cuantitativo transversal. Los datos sobre la clasificación de riesgo se obtuvieron a través de una búsqueda de los datos de registro informático de los registros médicos de los pacientes tratados en la emergencia pediátrica en el período de un año. Para el análisis se utilizó la estadística descriptiva con frecuencias absolutas y relativas. se llevaron a cabo 10.921 consultas en urgencias pediátricas, en su mayoría hombres (54,4%), con edades comprendidas entre 29 días y dos años (44,5%). Hubo una prevalencia de la categoría de riesgo urgente (43,6%). El diagrama de flujo principal utilizado en los cuidados fue padres preocupados (22,4%) y el discriminador más prevalente fue el evento reciente (15,3%). El resultado de internación se produjo en el 10,4% de los casos realizados en la emergencia pediátrica, sin embargo el 61,8% de las visitas precisaron permanecer en observación y/o estar bajo el cuidado del equipo de atención médica en la emergencia pediátrica. padres preocupados fue el diagrama de flujo principal utilizado y los eventos recientes el discriminador más frecuente, constatando los resultados de hospitalización y permanencia en la observación en la emergencia pediátrica antes del alta a la casa.
Characterization of calcium crystals in Abelia using x-ray diffraction and electron microscopes
USDA-ARS?s Scientific Manuscript database
Localization, chemical composition, and morphology of calcium crystals in leaves and stems of Abelia mosanensis and A. ×grandiflora were analyzed with a variable pressure scanning electron microscope (VP-SEM) equipped with an X-ray diffraction system, low temperature SEM (LT-SEM) and a transmission ...
On the Nature of SEM Estimates of ARMA Parameters.
ERIC Educational Resources Information Center
Hamaker, Ellen L.; Dolan, Conor V.; Molenaar, Peter C. M.
2002-01-01
Reexamined the nature of structural equation modeling (SEM) estimates of autoregressive moving average (ARMA) models, replicated the simulation experiments of P. Molenaar, and examined the behavior of the log-likelihood ratio test. Simulation studies indicate that estimates of ARMA parameters observed with SEM software are identical to those…
SEM (Symmetry Equivalent Molecules): a web-based GUI to generate and visualize the macromolecules
Hussain, A. S. Z.; Kumar, Ch. Kiran; Rajesh, C. K.; Sheik, S. S.; Sekar, K.
2003-01-01
SEM, Symmetry Equivalent Molecules, is a web-based graphical user interface to generate and visualize the symmetry equivalent molecules (proteins and nucleic acids). In addition, the program allows the users to save the three-dimensional atomic coordinates of the symmetry equivalent molecules in the local machine. The widely recognized graphics program RasMol has been deployed to visualize the reference (input atomic coordinates) and the symmetry equivalent molecules. This program is written using CGI/Perl scripts and has been interfaced with all the three-dimensional structures (solved using X-ray crystallography) available in the Protein Data Bank. The program, SEM, can be accessed over the World Wide Web interface at http://dicsoft2.physics.iisc.ernet.in/sem/ or http://144.16.71.11/sem/. PMID:12824326
Investigation of hidden periodic structures on SEM images of opal-like materials using FFT and IFFT.
Stephant, Nicolas; Rondeau, Benjamin; Gauthier, Jean-Pierre; Cody, Jason A; Fritsch, Emmanuel
2014-01-01
We have developed a method to use fast Fourier transformation (FFT) and inverse fast Fourier transformation (IFFT) to investigate hidden periodic structures on SEM images. We focused on samples of natural, play-of-color opals that diffract visible light and hence are periodically structured. Conventional sample preparation by hydrofluoric acid etch was not used; untreated, freshly broken surfaces were examined at low magnification relative to the expected period of the structural features, and, the SEM was adjusted to get a very high number of pixels in the images. These SEM images were treated by software to calculate autocorrelation, FFT, and IFFT. We present how we adjusted SEM acquisition parameters for best results. We first applied our procedure on an SEM image on which the structure was obvious. Then, we applied the same procedure on a sample that must contain a periodic structure because it diffracts visible light, but on which no structure was visible on the SEM image. In both cases, we obtained clearly periodic patterns that allowed measurements of structural parameters. We also investigated how the irregularly broken surface interfered with the periodic structure to produce additional periodicity. We tested the limits of our methodology with the help of simulated images. © 2014 Wiley Periodicals, Inc.
Bok, Jan; Schauer, Petr
2014-01-01
In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector's influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated e-beam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart-Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the e-beam scan. The results demonstrate the great benefit of the description of SEM detectors using the MTF and DQE. In addition, point-by-point and continual-sweep e-beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF. © 2013 Wiley Periodicals, Inc.
Optimization of SEM-EDS to determine the C–A–S–H composition in matured cement paste samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rossen, J.E., E-mail: john.rossen@alumni.epfl.ch
Microanalysis of characteristic X-rays in the SEM is a powerful method to assess the chemical composition of phases in cement pastes, in particular the calcium silicate hydrate containing aluminium (C–A–S–H). Nevertheless, many variables may influence the results obtained, due mainly to the intimate mixing of C–A–S–H with other hydrate phases and the susceptibility of this phase to damage by the electron beam. In this study the effect of various acquisition parameters was examined, along with methods to determine an “average” C–A–S–H composition. The results acquired in the SEM were compared with the analysis of the same samples in the TEM,more » where phases can be analyzed without intermixing. A simple method was used to obtain compositions from SEM based analysis that are very close to those which can be obtained in the TEM. - Highlights: •The intermixing of phases is the limiting factor in the analysis of C–A–S–H composition by SEM-EDS •Guidelines to limit beam damage and properly analyze C–A–S–H composition by SEM-EDS are given •SEM-EDS and TEM-EDS give similar results when proper data treatment is made.« less
NASA Technical Reports Server (NTRS)
Edmunson, J.; Gaskin, J. A.; Jerman, G. A.; Harvey, R. P.; Doloboff, I. J.; Neidholdt, E. L.
2016-01-01
The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.
FIB-SEM cathodoluminescence tomography: practical and theoretical considerations.
De Winter, D A M; Lebbink, M N; Wiggers De Vries, D F; Post, J A; Drury, M R
2011-09-01
Focused ion beam-scanning electron microscope (FIB-SEM) tomography is a powerful application in obtaining three-dimensional (3D) information. The FIB creates a cross section and subsequently removes thin slices. The SEM takes images using secondary or backscattered electrons, or maps every slice using X-rays and/or electron backscatter diffraction patterns. The objective of this study is to assess the possibilities of combining FIB-SEM tomography with cathodoluminescence (CL) imaging. The intensity of CL emission is related to variations in defect or impurity concentrations. A potential problem with FIB-SEM CL tomography is that ion milling may change the defect state of the material and the CL emission. In addition the conventional tilted sample geometry used in FIB-SEM tomography is not compatible with conventional CL detectors. Here we examine the influence of the FIB on CL emission in natural diamond and the feasibility of FIB-SEM CL tomography. A systematic investigation establishes that the ion beam influences CL emission of diamond, with a dependency on both the ion beam and electron beam acceleration voltage. CL emission in natural diamond is enhanced particularly at low ion beam and electron beam voltages. This enhancement of the CL emission can be partly explained by an increase in surface defects induced by ion milling. CL emission enhancement could be used to improve the CL image quality. To conduct FIB-SEM CL tomography, a recently developed novel specimen geometry is adopted to enable sequential ion milling and CL imaging on an untilted sample. We show that CL imaging can be manually combined with FIB-SEM tomography with a modified protocol for 3D microstructure reconstruction. In principle, automated FIB-SEM CL tomography should be feasible, provided that dedicated CL detectors are developed that allow subsequent milling and CL imaging without manual intervention, as the current CL detector needs to be manually retracted before a slice can be milled. Due to the required high electron beam acceleration voltage for CL emission, the resolution for FIB-SEM CL tomography is currently limited to several hundreds of nm in XY and up to 650 nm in Z for diamonds. Opaque materials are likely to have an improved Z resolution, as CL emission generated deeper in the material is not able to escape from it. © 2011 The Authors Journal of Microscopy © 2011 Royal Microscopical Society.
Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Sato, Yuki; Hikichi, Takuto; Ohira, Hiromasa
2017-01-01
AIM To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents (SEMSs). METHODS This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography (ERCP) procedures between the two groups. RESULTS The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices (ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve (sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. CONCLUSION A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement. PMID:28974893
Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Sato, Yuki; Hikichi, Takuto; Ohira, Hiromasa
2017-09-14
To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents (SEMSs). This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography (ERCP) procedures between the two groups. The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices (ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve (sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement.
Viegas, Ivan; Rito, João; Jarak, Ivana; Leston, Sara; Caballero-Solares, Albert; Metón, Isidoro; Pardal, Miguel A; Baanante, Isabel V; Jones, John G
2015-05-14
In the present study, the effects of partial substitution of dietary protein by digestible starch on endogenous glucose production were evaluated in European seabass (Dicentrarchus labrax). The fractional contribution of dietary carbohydrates v. gluconeogenesis to blood glucose appearance and hepatic glycogen synthesis was quantified in two groups of seabass fed with a diet containing 30% digestible starch (DS) or without a carbohydrate supplement as the control (CTRL). Measurements were performed by transferring the fish to a tank containing water enriched with 5% (2)H2O over the last six feeding days, and quantifying the incorporation of (2)H into blood glucose and hepatic glycogen by (2)H NMR. For CTRL fish, gluconeogenesis accounted for the majority of circulating glucose while for the DS fish, this contribution was significantly lower (CTRL 85 (SEM 4) % v. DS 54 (SEM 2) %; P < 0.001). Hepatic glycogen synthesis via gluconeogenesis (indirect pathway) was also significantly reduced in the DS fish, in both relative (CTRL 100 (SEM 1) % v. DS 72 (SEM 1) %; P < 0.001) and absolute terms (CTRL 28 (SEM 1) v. DS 17 (sem 1) μmol/kg per h; P < 0.001). A major fraction of the dietary carbohydrates that contributed to blood glucose appearance (33 (sem 1) % of the total 47 (SEM 2) %) had undergone exchange with hepatic glucose 6-phosphate. This indicated the simultaneous activity of hepatic glucokinase and glucose 6-phosphatase. In conclusion, supplementation of digestible starch resulted in a significant reduction of gluconeogenic contributions to systemic glucose appearance and hepatic glycogen synthesis.
Soderlund, Claes; Linder, Stefan; Bergenzaun, Per E; Grape, Tomas; Hakansson, Hans-Olof; Kilander, Anders; Lindell, Gert; Ljungman, Martin; Ohlin, Bo; Nielsen, Jorgen; Rudberg, Claes; Stotzer, Per-Ove; Svartholm, Erik; Toth, Ervin; Frozanpor, Farshad
2014-11-01
Covered nitinol alloy self-expandable metal stents (SEMSs) have been developed to overcome the shortcomings of steel SEMS in patients with malignant biliary obstruction. In a randomized, multicenter trial, we compared stent patency, patient survival, and adverse events in patients with partly covered stents made from steel or nitinol. A total of 400 patients with unresectable distal malignant biliary obstruction were randomized at endoscopic retrograde cholangiopancreatography (ERCP) to insertion of a steel or nitinol partially covered SEMS, with 200 patients in each group. The primary outcome was confirmed stent failure during 300 days of follow-up. At 300 days, the proportion of patients with patent stents was 77 % in the steel group, compared with 89 % in the nitinol group (P = 0.01). Confirmed stent failure occurred more often in the steel SEMS group compared with the nitinol SEMS group, in 30 versus 14 patients (P = 0.02). Stent migration occurred in 13 patients in the steel group and in 3 patients in the nitinol group (P = 0.01). Median patient survival (secondary outcome) was 137 days and 120 days in the steel SEMS and nitinol SEMS groups, respectively (P = 0.59). The nitinol SEMS showed longer patency time, and the nitinol group had fewer patients with stent failure, compared with the steel SEMS group. We could not detect any differences between the two groups regarding survival time, and regarding adverse event rate.Clinical trial registration : NCT 00980889. © Georg Thieme Verlag KG Stuttgart · New York.
Yamashita, Shinya; Tanemura, Masahiro; Sawada, Genta; Moon, Jeongho; Shimizu, Yosuke; Yamaguchi, Toshiki; Kuwai, Toshio; Urata, Yasuo; Kuraoka, Kazuya; Hatanaka, Nobutaka; Yamashita, Yoshinori; Taniyama, Kiyomi
2018-01-01
The placement of a self-expanding metallic stent (SEMS) in obstructive colorectal cancer (OCRC) is acknowledged to be a safe and effective procedure for the relief of obstruction. However, there is concern that shear forces acting on the tumor during stent expansion may release cancer cells into the circulation, resulting in a poor prognosis. The aim of the present study was to determine whether colonic stent insertion increases viable circulating tumor cells (v-CTCs). A telomerase-specific replication-selective adenovirus-expressing GFP (TelomeScanF35) detection system was used to detect v-CTCs in 8 OCRC patients with a SEMS before and after stent insertion and after surgical resection. In 7 patients, a SEMS was inserted as a bridge to surgery (BTS), and in one patient, a SEMS was inserted for palliation. Surgical resection (R0) was performed in 7 patients. Four patients had no v-CTCs before SEMS placement, two of four measurable patients had an increased number of v-CTCs after SEMS placement (1–3 v-CTCs), and one of two patients with increased v-CTCs developed distant lymphatic metastasis despite curative resection. Four patients had v-CTCs (1–19 cells) before SEMS placement, and two of these four patients had an increase in the number of v-CTCs (20–21 cells) after SEMS placement, while one of the four patients died early with distant metastasis. The present study demonstrated that endoscopic stent insertion for OCRC may result in tumor cell dissemination into the peripheral circulation and may induce distant metastases. PMID:29391884
Yamashita, Shinya; Tanemura, Masahiro; Sawada, Genta; Moon, Jeongho; Shimizu, Yosuke; Yamaguchi, Toshiki; Kuwai, Toshio; Urata, Yasuo; Kuraoka, Kazuya; Hatanaka, Nobutaka; Yamashita, Yoshinori; Taniyama, Kiyomi
2018-01-01
The placement of a self-expanding metallic stent (SEMS) in obstructive colorectal cancer (OCRC) is acknowledged to be a safe and effective procedure for the relief of obstruction. However, there is concern that shear forces acting on the tumor during stent expansion may release cancer cells into the circulation, resulting in a poor prognosis. The aim of the present study was to determine whether colonic stent insertion increases viable circulating tumor cells (v-CTCs). A telomerase-specific replication-selective adenovirus-expressing GFP (TelomeScanF35) detection system was used to detect v-CTCs in 8 OCRC patients with a SEMS before and after stent insertion and after surgical resection. In 7 patients, a SEMS was inserted as a bridge to surgery (BTS), and in one patient, a SEMS was inserted for palliation. Surgical resection (R0) was performed in 7 patients. Four patients had no v-CTCs before SEMS placement, two of four measurable patients had an increased number of v-CTCs after SEMS placement (1-3 v-CTCs), and one of two patients with increased v-CTCs developed distant lymphatic metastasis despite curative resection. Four patients had v-CTCs (1-19 cells) before SEMS placement, and two of these four patients had an increase in the number of v-CTCs (20-21 cells) after SEMS placement, while one of the four patients died early with distant metastasis. The present study demonstrated that endoscopic stent insertion for OCRC may result in tumor cell dissemination into the peripheral circulation and may induce distant metastases.
Saccadic Eye Movement Improves Plantar Sensation and Postural Balance in Elderly Women.
Bae, Youngsook
2016-06-01
Vision, proprioception and plantar sensation contribute to the control of postural balance (PB). Reduced plantar sensation alters postural response and is at an increased risk of fall, and eye movements reduce the postural sway. Therefore, the aim of this study was to study the improvement of plantar sensation and PB after saccadic eye movement (SEM) and pursuit eye movement (PEM) in community-dwelling elderly women. Participants (104 females; 75.11 ± 6.25 years) were randomly allocated into the SEM group (n = 52) and PEM groups (n = 52). The SEM group performed eye fixation and SEM for 5 minutes, and the PEM group performed eye fixation and PEM for 5 minutes. The plantar sensation was measured according to the plantar surface area of the feet in contact with the floor surface before and after the intervention. Before and after SEM and PEM with the eyes open and closed, PB was measured as the area (mm(2)), length (cm), and velocity (cm/s) of the fluctuation of the center of pressure (COP). The plantar sensation of both feet improved in both groups (p < 0.01). Significant decreases in the area, length, and velocity of the COP were observed in the eye open and close in both groups (p < 0.01). The length and velocity of the COP significantly decreased in the SEM group compared to the PEM group (p < 0.05). In conclusion, SEM and PEM are effective interventions for improving plantar sensation and PB in elderly women, with greater PB improvement after SEM.
Bootstrap Estimation of Sample Statistic Bias in Structural Equation Modeling.
ERIC Educational Resources Information Center
Thompson, Bruce; Fan, Xitao
This study empirically investigated bootstrap bias estimation in the area of structural equation modeling (SEM). Three correctly specified SEM models were used under four different sample size conditions. Monte Carlo experiments were carried out to generate the criteria against which bootstrap bias estimation should be judged. For SEM fit indices,…
30 CFR 250.1909 - What are management's general responsibilities for the SEMS program?
Code of Federal Regulations, 2012 CFR
2012-07-01
... ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL... intervals specified in the SEMS program and at least annually, review the SEMS program to determine if it... recommendations of that review. (e) Develop and endorse a written description of your safety and environmental...
30 CFR 250.1909 - What are management's general responsibilities for the SEMS program?
Code of Federal Regulations, 2013 CFR
2013-07-01
... ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL... intervals specified in the SEMS program and at least annually, review the SEMS program to determine if it... recommendations of that review. (e) Develop and endorse a written description of your safety and environmental...
30 CFR 250.1909 - What are management's general responsibilities for the SEMS program?
Code of Federal Regulations, 2014 CFR
2014-07-01
... ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL... intervals specified in the SEMS program and at least annually, review the SEMS program to determine if it... recommendations of that review. (e) Develop and endorse a written description of your safety and environmental...
30 CFR 250.1909 - What are management's general responsibilities for the SEMS program?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE... performance of the SEMS program. (d) At intervals specified in the SEMS program and at least annually, review... the observations, conclusions and recommendations of that review. (e) Develop and endorse a written...
Some Esoteric Aspects of SEM that Its Practitioners Should Want to Know
ERIC Educational Resources Information Center
Rozeboom, William W.
2009-01-01
The topic of this article is the interpretation of structural equation modeling (SEM) solutions. Its purpose is to augment structural modeling's metatheoretic resources while enhancing awareness of how problematic is the causal significance of SEM-parameter solutions. Part I focuses on the nonuniqueness and consequent dubious interpretability of…
30 CFR 250.1916 - What criteria for mechanical integrity must my SEMS program meet?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 2 2011-07-01 2011-07-01 false What criteria for mechanical integrity must my SEMS program meet? 250.1916 Section 250.1916 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT... mechanical integrity must my SEMS program meet? You must develop and implement written procedures that...
30 CFR 250.1924 - How will BOEMRE determine if my SEMS program is effective?
Code of Federal Regulations, 2011 CFR
2011-07-01
... protecting the safety and health of workers, the environment, and preventing incidents. BOEMRE or its..., (2) You can explain and demonstrate the procedures and policies included in your SEMS program; and (3) You can produce evidence to support the implementation of your SEMS program. (d) Representatives from...
Stephant, Nicolas; Grissa, Rabeb; Guillou, Fanch; Bretaudeau, Mickaël; Borjon-Piron, Yann; Guillet, Jacques; Moreau, Philippe
2018-04-18
The surface of some materials reacts very quickly on contact with air, either because it is oxidized or because it gets humidity from the air. For the sake of original surface observation by scanning electron microscopy (SEM), we conceived an airtight transfer box to keep the samples under vacuum from the place of manufacturing to the SEM chamber. This object is designed to fit in all the models of SEM including those provided with an airlock chamber. The design is voluntarily simplified to allow the manufacturing of the object by a standard mechanical workshop. The transfer box can be easily opened by gravity inside the SEM and allows the preservation of the best vacuum inside, before opening. SEM images and energy dispersive spectroscopy (EDX) analyses of metallic lithium and sodium samples are presented prior and after exposure to the air. X-ray Photoelectron Spectroscopy (XPS) analyses of all samples are also discussed in order to investigate the chemical environments of the detected elements. Copyright © 2018 Elsevier Ltd. All rights reserved.
van Oosten, Johanna M F; Peter, Jochen; Boot, Inge
2015-01-01
Previous research on women's responses to male-targeted sexually explicit material (SEM) suggests that women may be critical toward such content. However, women's critical responses to SEM have not been explained empirically. The present study had two goals: (1) to investigate whether women's critical responses to male-targeted SEM depend on individual differences in gender role orientation (i.e., hyperfemininity) and (2) to explain the effect of hyperfemininity on critical responses to SEM by looking at the way sexual material is processed. In an online experiment among women aged 18 to 30 (N = 195), both the type of SEM (a male- versus female-targeted erotic story) and processing style (stimulus- versus response-focused) were manipulated. In addition, participants were divided into three groups based on low, moderate, or high hyperfemininity. When using stimulus-focused processing (i.e., attending to the characters and situational context of the story), women were more critical toward male-targeted SEM (relative to female-targeted material), but only when they had low and moderate degrees of hyperfemininity.
In Situ Characterization of Boehmite Particles in Water Using Liquid SEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, Juan; Arey, Bruce W.; Yang, Li
In situ imaging and elemental analysis of boehmite (AlOOH) particles in water is realized using the System for Analysis at the Liquid Vacuum Interface (SALVI) and Scanning Electron Microscopy (SEM). This paper describes the method and key steps in integrating the vacuum compatible SAVLI to SEM and obtaining secondary electron (SE) images of particles in liquid in high vacuum. Energy dispersive x-ray spectroscopy (EDX) is used to obtain elemental analysis of particles in liquid. A synthesized AlOOH particle is used as a model in the liquid SEM illustration. Our results demonstrate that particles can be imaged in the SE modemore » with good resolution. The AlOOH EDX spectrum shows significant signal from the Al compared with deionized water and the empty channel control. In situ liquid SEM is a powerful technique to study particles in liquid with many exciting applications. This procedure aims to provide technical details in how to conduct liquid SEM imaging and EDX analysis using SALVI and reduce potential pitfalls using this approach for other researchers.« less
Nizoli, Erico Casare; Luiz-Silva, Wanilson
2012-04-01
In anoxic sediments, as those found in estuaries, the mobility of metals can be controlled by the formation of stable sulfide complexes. The potential bioavailability of a metal can then be predicted on the basis of the acid volatile sulfide (AVS) and simultaneously extracted metals (SEM) criterion. Distributions of AVS and SEM (Hg, Cu, Pb, Cd, Zn, and Ni) along the sediment profiles were determined seasonally for three rivers that constitute the Santos-Cubatão estuarine system (SE Brazil), which is located in one of the most industrialized areas of Latin America. AVS and SEM concentrations varied significantly, from 0.04 to 31.9 μmol g(-1) and 0.086-6.659 μmol g(-1), respectively. The highest AVS levels in sediments were detected in the winter, whereas high SEM values predominated in the summer. Considering SEM-AVS molar differences as a parameter to evaluate potential bioavailability, sediments nearest to the industrial area represent higher risk to biota, especially during the summer. It is due to relatively low AVS values and not necessarily high concentrations of metals.
Scanning electron microscope image signal-to-noise ratio monitoring for micro-nanomanipulation.
Marturi, Naresh; Dembélé, Sounkalo; Piat, Nadine
2014-01-01
As an imaging system, scanning electron microscope (SEM) performs an important role in autonomous micro-nanomanipulation applications. When it comes to the sub micrometer range and at high scanning speeds, the images produced by the SEM are noisy and need to be evaluated or corrected beforehand. In this article, the quality of images produced by a tungsten gun SEM has been evaluated by quantifying the level of image signal-to-noise ratio (SNR). In order to determine the SNR, an efficient and online monitoring method is developed based on the nonlinear filtering using a single image. Using this method, the quality of images produced by a tungsten gun SEM is monitored at different experimental conditions. The derived results demonstrate the developed method's efficiency in SNR quantification and illustrate the imaging quality evolution in SEM. © 2014 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, James
Strategic energy management (SEM) focuses on achieving energy-efficiency improvements through systematic and planned changes in facility operations, maintenance, and behaviors (OM&B) and capital equipment upgrades in large energy-using facilities, including industrial buildings, commercial buildings, and multi-facility organizations such as campuses or communities. Facilities can institute a spectrum of SEM actions, ranging from a simple process for regularly identifying energy-savings actions, to establishing a formal, third-party recognized or certified SEM framework for continuous improvement of energy performance. In general, SEM programs that would be considered part of a utility program will contain a set of energy-reducing goals, principles, and practices emphasizingmore » continuous improvements in energy performance or savings through energy management and an energy management system (EnMS).« less
FIB/SEM and SEM/EDS microstructural analysis of metal-ceramic and zirconia-ceramic interfaces.
Massimi, F; Merlati, G; Sebastiani, M; Battaini, P; Menghini, P; Bemporad, E
2012-01-10
Recently introduced FIB/SEM analysis in microscopy seems to provide a high-resolution characterization of the samples by 3D (FIB) cross-sectioning and (SEM) high resolution imaging. The aim of this study was to apply the FIB/SEM and SEM/EDS analysis to the interfaces of a metal-ceramic vs. two zirconia-ceramic systems. Plate samples of three different prosthetic systems were prepared in the dental lab following the manufacturers' instructions, where metal-ceramic was the result of a ceramic veneering (porcelain-fused-to-metal) and the two zirconia-ceramic systems were produced by the dedicated CAD-CAM procedures of the zirconia cores (both with final sintering) and then veneered by layered or heat pressed ceramics. In a FIB/SEM equipment (also called DualBeam), a thin layer of platinum (1 μm) was deposited on samples surface crossing the interfaces, in order to protect them during milling. Then, increasingly deeper trenches were milled by a focused ion beam, first using a relatively higher and later using a lower ion current (from 9 nA to 0.28 nA, 30KV). Finally, FEG-SEM (5KV) micrographs (1000-50,000X) were acquired. In a SEM the analysis of the morphology and internal microstructure was performed by 13KV secondary and backscattered electrons signals (in all the samples). The compositional maps were then performed by EDS probe only in the metal-ceramic system (20kV). Despite the presence of many voids in all the ceramic layers, it was possible to identify: (1) the grain structures of the metallic and zirconia substrates, (2) the thin oxide layer at the metal-ceramic interface and its interactions with the first ceramic layer (wash technique), (3) the roughness of the two different zirconia cores and their interactions with the ceramic interface, where the presence of zirconia grains in the ceramic layer was reported in two system possibly due to sandblasting before ceramic firing.
Wacker, Irene U.; Veith, Lisa; Spomer, Waldemar; Hofmann, Andreas; Thaler, Marlene; Hillmer, Stefan; Gengenbach, Ulrich; Schröder, Rasmus R.
2018-01-01
Targeting specific cells at ultrastructural resolution within a mixed cell population or a tissue can be achieved by hierarchical imaging using a combination of light and electron microscopy. Samples embedded in resin are sectioned into arrays consisting of ribbons of hundreds of ultrathin sections and deposited on pieces of silicon wafer or conductively coated coverslips. Arrays are imaged at low resolution using a digital consumer like smartphone camera or light microscope (LM) for a rapid large area overview, or a wide field fluorescence microscope (fluorescence light microscopy (FLM)) after labeling with fluorophores. After post-staining with heavy metals, arrays are imaged in a scanning electron microscope (SEM). Selection of targets is possible from 3D reconstructions generated by FLM or from 3D reconstructions made from the SEM image stacks at intermediate resolution if no fluorescent markers are available. For ultrastructural analysis, selected targets are finally recorded in the SEM at high-resolution (a few nanometer image pixels). A ribbon-handling tool that can be retrofitted to any ultramicrotome is demonstrated. It helps with array production and substrate removal from the sectioning knife boat. A software platform that allows automated imaging of arrays in the SEM is discussed. Compared to other methods generating large volume EM data, such as serial block-face SEM (SBF-SEM) or focused ion beam SEM (FIB-SEM), this approach has two major advantages: (1) The resin-embedded sample is conserved, albeit in a sliced-up version. It can be stained in different ways and imaged with different resolutions. (2) As the sections can be post-stained, it is not necessary to use samples strongly block-stained with heavy metals to introduce contrast for SEM imaging or render the tissue blocks conductive. This makes the method applicable to a wide variety of materials and biological questions. Particularly prefixed materials e.g., from biopsy banks and pathology labs, can directly be embedded and reconstructed in 3D. PMID:29630046
Fuller, John C; Sharp, Rick L; Angus, Hector F; Baier, Shawn M; Rathmacher, John A
2011-02-01
The leucine metabolite, β-hydroxy-β-methylbutyrate (HMB), is a nutritional supplement that increases lean muscle and strength with exercise and in disease states. HMB is presently available as the Ca salt (CaHMB). The present study was designed to examine whether HMB in free acid gel form will improve HMB availability to tissues. Two studies were conducted and in each study four males and four females were given three treatments in a randomised, cross-over design. Treatments were CaHMB (gelatin capsule, 1 g), equivalent HMB free acid gel swallowed (FASW) and free acid gel held sublingual for 15 s then swallowed (FASL). Plasma HMB was measured for 3 h following treatment in study 1 and 24 h with urine collection in study 2. In both the studies, the times to peak plasma HMB were 128 (sem 11), 38 (sem 4) and 38 (sem 1) min (P < 0·0001) for CaHMB, FASW and FASL, respectively. The peak concentrations were 131 (sem 6), 249 (sem 14) and 239 (sem 14) μmol/l (P < 0·0001) for CaHMB, FASW and FASL, respectively. The areas under the curve were almost double for FASW and FASL (P < 0·0001). Daily urinary HMB excretion was not significantly increased resulting in more HMB retained (P < 0·003) with FASW and FASL. Half-lives were 3·17 (sem 0·22), 2·50 (sem 0·13) and 2·51 (sem 0·14) h for CaHMB, FASW and FASL, respectively (P < 0·004). Free acid gel resulted in quicker and greater plasma concentrations (+185%) and improved clearance (+25%) of HMB from plasma. In conclusion, HMB free acid gel could improve HMB availability and efficacy to tissues in health and disease.
Sim, K S; Kiani, M A; Nia, M E; Tso, C P
2014-01-01
A new technique based on cubic spline interpolation with Savitzky-Golay noise reduction filtering is designed to estimate signal-to-noise ratio of scanning electron microscopy (SEM) images. This approach is found to present better result when compared with two existing techniques: nearest neighbourhood and first-order interpolation. When applied to evaluate the quality of SEM images, noise can be eliminated efficiently with optimal choice of scan rate from real-time SEM images, without generating corruption or increasing scanning time. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.
The SEM description of interaction of a transient electromagnetic wave with an object
NASA Technical Reports Server (NTRS)
Pearson, L. W.; Wilton, D. R.
1980-01-01
The singularity expansion method (SEM), proposed as a means for determining and representing the transient surface current density induced on a scatterer by a transient electromagnetic wave is described. The resulting mathematical description of the transient surface current on the object is discussed. The data required to represent the electromagnetic scattering properties of a given object are examined. Experimental methods which were developed for the determination of the SEM description are discussed. The feasibility of characterizing the surface current induced on aircraft flying in proximity to a lightning stroke by way of SEM is examined.
A Simulation of the Topographic Contrast in the SEM
NASA Astrophysics Data System (ADS)
Kotera, Masatoshi; Fujiwara, Takafumi; Suga, Hiroshi; Wittry, David B.
1990-10-01
A simulation model is presented to analyze the topographic contast in the scanning electron microscope (SEM). This simulation takes into account all major mechanisms from signal generation to signal detection in the SEM. The calculated result shows that the resolution of the secondary electron image is better than that of the backscattered electron image for 1 and 3 keV primary electrons incident on an Al target. An asymmetric intensity profile of a signal at a topographic pattern, usually found in the SEM equipped with the Everhart-Thornley detector, is mainly due to the asymmetric profile of the backscattered electron signal.
Understanding the Mechanical forces of Self-Expandable Metal Stents in the Biliary Ducts.
Isayama, Hiroyuki; Nakai, Yousuke; Hamada, Tsuyoshi; Matsubara, Saburo; Kogure, Hirofumi; Koike, Kazuhiko
2016-12-01
Self-expandable metallic stent (SEMS) was an effective biliary endoprosthesis. Mechanical properties of SEMS, radial and axial force (RF, AF), may play important roles in the bile duct after placement. RF was well known dilation force and influenced on the occurrence of migration. AF, newly proposed by this author, was defined as the recovery force when the SEMS vended. AF was related with the cause of bile duct kinking, pancreatitis, and cholecystitis due to the compression of the bile duct, orifice of the cystic duct, and pancreatic orifice. Ideal SEMS may show high RF and low AF.
Raman-in-SEM, a multimodal and multiscale analytical tool: performance for materials and expertise.
Wille, Guillaume; Bourrat, Xavier; Maubec, Nicolas; Lahfid, Abdeltif
2014-12-01
The availability of Raman spectroscopy in a powerful analytical scanning electron microscope (SEM) allows morphological, elemental, chemical, physical and electronic analysis without moving the sample between instruments. This paper documents the metrological performance of the SEMSCA commercial Raman interface operated in a low vacuum SEM. It provides multiscale and multimodal analyses as Raman/EDS, Raman/cathodoluminescence or Raman/STEM (STEM: scanning transmission electron microscopy) as well as Raman spectroscopy on nanomaterials. Since Raman spectroscopy in a SEM can be influenced by several SEM-related phenomena, this paper firstly presents a comparison of this new tool with a conventional micro-Raman spectrometer. Then, some possible artefacts are documented, which are due to the impact of electron beam-induced contamination or cathodoluminescence contribution to the Raman spectra, especially with geological samples. These effects are easily overcome by changing or adapting the Raman spectrometer and the SEM settings and methodology. The deletion of the adverse effect of cathodoluminescence is solved by using a SEM beam shutter during Raman acquisition. In contrast, this interface provides the ability to record the cathodoluminescence (CL) spectrum of a phase. In a second part, this study highlights the interest and efficiency of the coupling in characterizing micrometric phases at the same point. This multimodal approach is illustrated with various issues encountered in geosciences. Copyright © 2014 Elsevier Ltd. All rights reserved.
The relationship between cost estimates reliability and BIM adoption: SEM analysis
NASA Astrophysics Data System (ADS)
Ismail, N. A. A.; Idris, N. H.; Ramli, H.; Rooshdi, R. R. Raja Muhammad; Sahamir, S. R.
2018-02-01
This paper presents the usage of Structural Equation Modelling (SEM) approach in analysing the effects of Building Information Modelling (BIM) technology adoption in improving the reliability of cost estimates. Based on the questionnaire survey results, SEM analysis using SPSS-AMOS application examined the relationships between BIM-improved information and cost estimates reliability factors, leading to BIM technology adoption. Six hypotheses were established prior to SEM analysis employing two types of SEM models, namely the Confirmatory Factor Analysis (CFA) model and full structural model. The SEM models were then validated through the assessment on their uni-dimensionality, validity, reliability, and fitness index, in line with the hypotheses tested. The final SEM model fit measures are: P-value=0.000, RMSEA=0.079<0.08, GFI=0.824, CFI=0.962>0.90, TLI=0.956>0.90, NFI=0.935>0.90 and ChiSq/df=2.259; indicating that the overall index values achieved the required level of model fitness. The model supports all the hypotheses evaluated, confirming that all relationship exists amongst the constructs are positive and significant. Ultimately, the analysis verified that most of the respondents foresee better understanding of project input information through BIM visualization, its reliable database and coordinated data, in developing more reliable cost estimates. They also perceive to accelerate their cost estimating task through BIM adoption.
Structural equation modeling for observational studies
Grace, J.B.
2008-01-01
Structural equation modeling (SEM) represents a framework for developing and evaluating complex hypotheses about systems. This method of data analysis differs from conventional univariate and multivariate approaches familiar to most biologists in several ways. First, SEMs are multiequational and capable of representing a wide array of complex hypotheses about how system components interrelate. Second, models are typically developed based on theoretical knowledge and designed to represent competing hypotheses about the processes responsible for data structure. Third, SEM is conceptually based on the analysis of covariance relations. Most commonly, solutions are obtained using maximum-likelihood solution procedures, although a variety of solution procedures are used, including Bayesian estimation. Numerous extensions give SEM a very high degree of flexibility in dealing with nonnormal data, categorical responses, latent variables, hierarchical structure, multigroup comparisons, nonlinearities, and other complicating factors. Structural equation modeling allows researchers to address a variety of questions about systems, such as how different processes work in concert, how the influences of perturbations cascade through systems, and about the relative importance of different influences. I present 2 example applications of SEM, one involving interactions among lynx (Lynx pardinus), mongooses (Herpestes ichneumon), and rabbits (Oryctolagus cuniculus), and the second involving anuran species richness. Many wildlife ecologists may find SEM useful for understanding how populations function within their environments. Along with the capability of the methodology comes a need for care in the proper application of SEM.
NASA Astrophysics Data System (ADS)
Ohtsuka, Y.; Yabunaka, Noriyuki; Takayama, Shigeru
The influence of ''shinrin-yoku'' (forest-air bathing and walking) on blood glucose levels in diabetic patients was examined. Eighty-seven (29 male and 58 female) non-insulin-dependent diabetic patients [61 (SEM 1) years old] participated in the present study. Shinrin-yoku was performed nine times over a period of 6 years. The patients were divided into two parties. They then walked in the forest for 3 km or 6 km according to their physical ability and/or the existence of diabetic complications. The mean blood glucose level after forest walking changed from 179 (SEM 4) mg . 100 ml-1 to 108 (SEM 2) mg . 100 ml-1 (P<0.0001). The level of glycated haemoglobin A1c also decreased from 6.9 (SEM 0.2)% (before the first shinrin-yoku) to 6.5 (SEM 0.1)% (after the last shinrin-yoku; P<0.05). Blood glucose values declined by 74 (SEM 9) mg . 100 ml-1 and 70 (SEM 4) mg . 100 ml-1 after short- and long-distance walking respectively. There was no significant difference between these values. Since the forest environment causes changes in hormonal secretion and autonomic nervous functions, it is presumed that, in addition to the increased calorie consumption and improved insulin sensitivity, walking in a forest environment has other beneficial effects in decreasing blood glucose levels.
ERIC Educational Resources Information Center
Yale, Amanda
2010-01-01
The first article in this two-part series focused on the need for enrollment management conceptual and organizational models to focus more intentionally and purposefully on efforts related to improving student learning, success, and persistence. Time and again, SEM is viewed from a conventional lens comprising marketing, recruitment and …
ERIC Educational Resources Information Center
Yale, Amanda
2010-01-01
It's now nearly ten years since the author started participating in and presenting at national conferences related to strategic enrollment management (SEM). Having entered this profession with nearly 20 years of experience in transitional initiatives related to the first-year experience and academic advisement services, she has perceived an…
ERIC Educational Resources Information Center
Cheung, Mike W. L.; Chan, Wai
2009-01-01
Structural equation modeling (SEM) is widely used as a statistical framework to test complex models in behavioral and social sciences. When the number of publications increases, there is a need to systematically synthesize them. Methodology of synthesizing findings in the context of SEM is known as meta-analytic SEM (MASEM). Although correlation…
Implementing Restricted Maximum Likelihood Estimation in Structural Equation Models
ERIC Educational Resources Information Center
Cheung, Mike W.-L.
2013-01-01
Structural equation modeling (SEM) is now a generic modeling framework for many multivariate techniques applied in the social and behavioral sciences. Many statistical models can be considered either as special cases of SEM or as part of the latent variable modeling framework. One popular extension is the use of SEM to conduct linear mixed-effects…
30 CFR 250.1917 - What criteria for pre-startup review must be in my SEMS program?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 2 2011-07-01 2011-07-01 false What criteria for pre-startup review must be in... pre-startup review must be in my SEMS program? Your SEMS program must require that the commissioning process include a pre-startup safety and environmental review for new and significantly modified...
ERIC Educational Resources Information Center
Wolf, Erika J.; Harrington, Kelly M.; Clark, Shaunna L.; Miller, Mark W.
2013-01-01
Determining sample size requirements for structural equation modeling (SEM) is a challenge often faced by investigators, peer reviewers, and grant writers. Recent years have seen a large increase in SEMs in the behavioral science literature, but consideration of sample size requirements for applied SEMs often relies on outdated rules-of-thumb.…
Coté, Gregory A; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K; Elmunzer, B Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart
Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of -15%. There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, -3.0% to ∞; P < .001). Given the prespecified noninferiority margin of -15%, the null hypothesis that cSEMS is less effective than plastic stents was rejected. The mean number of ERCPs to achieve resolution was lower for cSEMS (2.14) vs plastic (3.24; mean difference, 1.10; 95% CI, 0.74 to 1.46; P < .001). Among patients with benign biliary strictures and a bile duct diameter 6 mm or more in whom the covered metallic stent would not overlap the cystic duct, cSEMS were not inferior to multiple plastic stents after 12 months in achieving stricture resolution. Metallic stents should be considered an appropriate option in patients such as these. clinicaltrials.gov Identifier: NCT01221311.
Rodrigues-Pinto, E; Pereira, P; Coelho, R; Andrade, P; Ribeiro, A; Lopes, S; Moutinho-Ribeiro, P; Macedo, G
2017-02-01
Self-expanding metal stents (SEMS) are the treatment of choice for advanced esophageal cancers. Literature is scarce on risk factors predictors for adverse events after SEMS placement. Assess risk factors for adverse events after SEMS placement in advanced esophageal cancer and evaluate survival after SEMS placement. Cross-sectional study of patients with advanced esophageal cancer referred for SEMS placement, during a period of 3 years. Ninety-seven patients with advanced esophageal cancer placed SEMS. Adverse events were more common when tumors were located at the level of the distal esophagus/cardia (47% vs 23%, P = 0.011, OR 3.1), with statistical significance being kept in the multivariate analysis (OR 3.1, P = 0.018). Time until adverse events was lower in the tumors located at the level of the distal esophagus/cardia (P = 0.036). Survival was higher in patients who placed SEMS with curative intent (327 days [126-528] vs. 119 days [91-147], P = 0.002) and in patients submitted subsequently to surgery compared with those who did just chemo/radiotherapy or who did not do further treatment (563 days [378-748] vs. 154 days [133-175] vs. 46 days [20-72], P < 0.001). Subsequent treatment kept statistical significance in the multivariate analysis (HR 3.4, P < 0.001). SEMS allow palliation of dysphagia in advanced esophageal cancer and are associated with an increased out-of-hospital survival, as long as there are conditions for further treatments. Tumors located at the level of the distal esophagus/cardia are associated with a greater number of adverse events, which also occur earlier. © 2016 International Society for Diseases of the Esophagus.
Nymo, Siren; Coutinho, Silvia R; Torgersen, Linn-Christin H; Bomo, Ola J; Haugvaldstad, Ingrid; Truby, Helen; Kulseng, Bård; Martins, Catia
2018-07-01
Diet-induced weight loss (WL) is associated with reduced resting and non-resting energy expenditure (EE), driven not only by changes in body composition but also potentially by adaptive thermogenesis (AT). When exactly this happens, during progressive WL, remains unknown. The aim of this study was to determine the timeline of changes in RMR and exercise-induced EE (EIEE), stemming from changes in body composition v. the presence of AT, during WL with a very-low-energy diet (VLED). In all, thirty-one adults (eighteen men) with obesity (BMI: 37 (sem 4·5) kg/m2; age: 43 (sem 10) years) underwent 8 weeks of a VLED, followed by 4 weeks of weight maintenance. Body weight and composition, RMR, net EIEE (10, 25 and 50 W) and AT (for RMR (ATRMR) and EIEE (ATEIEE)) were measured at baseline, day 3 (2 (sem 1) % WL), after 5 and 10 % WL and at weeks 9 (16 (sem 2) %) and 13 (16 (sem 1) %). RMR and fat mass were significantly reduced for the first time at 5 % WL (12 (sem 8) d) (P<0·01 and P<0·001, respectively) and EIEE at 10 % WL (32 (sem 8) d), for all levels of power (P<0·05), and sustained up to week 13. ATRMR was transiently present at 10 % WL (-460 (sem 690) kJ/d, P<0·01). A fall in RMR should be anticipated at ≥5 % WL and a reduction in EIEE at ≥10 % WL. Transient ATRMR can be expected at 10 % WL. These physiological adaptations may make progressive WL difficult and will probably contribute to relapse.
Advanced metrology by offline SEM data processing
NASA Astrophysics Data System (ADS)
Lakcher, Amine; Schneider, Loïc.; Le-Gratiet, Bertrand; Ducoté, Julien; Farys, Vincent; Besacier, Maxime
2017-06-01
Today's technology nodes contain more and more complex designs bringing increasing challenges to chip manufacturing process steps. It is necessary to have an efficient metrology to assess process variability of these complex patterns and thus extract relevant data to generate process aware design rules and to improve OPC models. Today process variability is mostly addressed through the analysis of in-line monitoring features which are often designed to support robust measurements and as a consequence are not always very representative of critical design rules. CD-SEM is the main CD metrology technique used in chip manufacturing process but it is challenged when it comes to measure metrics like tip to tip, tip to line, areas or necking in high quantity and with robustness. CD-SEM images contain a lot of information that is not always used in metrology. Suppliers have provided tools that allow engineers to extract the SEM contours of their features and to convert them into a GDS. Contours can be seen as the signature of the shape as it contains all the dimensional data. Thus the methodology is to use the CD-SEM to take high quality images then generate SEM contours and create a data base out of them. Contours are used to feed an offline metrology tool that will process them to extract different metrics. It was shown in two previous papers that it is possible to perform complex measurements on hotspots at different process steps (lithography, etch, copper CMP) by using SEM contours with an in-house offline metrology tool. In the current paper, the methodology presented previously will be expanded to improve its robustness and combined with the use of phylogeny to classify the SEM images according to their geometrical proximities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, D.; Berry, W.; Benyi, S.
1995-12-31
The role of interstitial cadmium and acid volatile sulfide (AVS) in controlling the bioavailability of sediment-associated metal was examined using the chronic saltwater benthic colonization test. Sediments were spiked with cadmium to achieve simultaneously extracted metal (SEM)/AVS molar ratios of 0. 0 (control), 0.1, 0.8 and 3.0 in this 118-day test. Oxidation of AVS in the surficial 2.4 cm within two to four weeks resulted in sulfide profiles similar to those occurring naturally in local sediments. In the nominal 0.1 SEM/AVS treatment, measured SEM was always less than AVS. Interstitial cadmium concentrations (< 3--10 {micro}g/L) were below those likely tomore » cause biological effects. No significant biological effects were detected. In the nominal 0.8 SEM/AVS treatment, measured SEM commonly exceeded AVS in the surficial 2.4 cm of sediment. Interstitial cadmium concentrations (24--157 {micro}g/L) were likely of toxicological significance to sensitive species. Shifts were observed in presence/absence of species, and there were fewer macrobenthic polychaetes (Mediomastus ambiseta, Strebloapio benedicti and Podarke obscura) and unidentified meiofaunal nematodes. In the nominal 3.0 SEM/AVS treatment, concentrations of SEM were always greater than AVS throughout the sediment column. Interstitial cadmium ranged from 28,000 to 174,000 {micro}g/L. In addition to the effects above, these sediments were colonized by fewer macrobenthic species, polychaete species and harpacticoids; had lower densities of diatoms; lacked bivalve molluscs and exhibited other impacts. The observed biological responses were consistent with measured SEM/AVS ratios in surficial sediments and interstitial water cadmium concentrations, further supporting their utility in predicting metals bioavailability.« less
Smith, Christopher E; Mollard, Rebecca C; Luhovyy, Bohdan L; Anderson, G Harvey
2012-08-01
Pulses are low-glycaemic foods rich in protein (20-25 %), resistant starch and fibre that suppress appetite and glycaemia. The objective of the present study was to elucidate the component(s) of yellow peas responsible for these benefits and assess their efficacy as value-added food ingredients. We investigated the effects of 10 or 20 g of isolated yellow pea protein (P10 and P20) or fibre (F10 and F20) on food intake (FI) at an ad libitum pizza meal served at 30 min (Expt 1, n 19) or 120 min (Expt 2, n 20) and blood glucose (BG) and appetite in young, healthy males (20-30 years). In Expt 1, P20 led to lower FI than control (4937 (sem 502) v. 5632 (sem 464) kJ (1180 (sem 120) v. 1346 (sem 111) kcal)) and all other treatments (P < 0·01) and lower cumulative FI (pizza meal kcal+treatment kcal; CFI) compared to F10 (5460 (sem 498) v. 6084 (sem 452) kJ (1305 (sem 119) v. 1454 (sem 108) kcal); P = 0·033). Both protein treatments suppressed mean pre-meal (0-30 min) BG compared to control (P < 0·05), whereas only P20 suppressed mean post-meal (50-120 min) BG (P < 0·01). There was no effect of treatment on pre-meal or post-meal appetite. In Expt 2, there was no effect of treatment on FI, CFI, or pre- or post-meal BG or appetite. In conclusion, protein is the component responsible for the short-term effects of yellow peas in the regulation of glycaemia and FI, but its second-meal effects disappear by 2 h post-consumption.
Rodenhizer, Kara Anne E; Edwards, Katie M
2017-01-01
Dating violence (DV) and sexual violence (SV) are widespread problems among adolescents and emerging adults. A growing body of literature demonstrates that exposure to sexually explicit media (SEM) and sexually violent media (SVM) may be risk factors for DV and SV. The purpose of this article is to provide a systematic and comprehensive literature review on the impact of exposure to SEM and SVM on DV and SV attitudes and behaviors. A total of 43 studies utilizing adolescent and emerging adult samples were reviewed, and collectively the findings suggest that (1) exposure to SEM and SVM is positively related to DV and SV myths and more accepting attitudes toward DV and SV; (2) exposure to SEM and SVM is positively related to actual and anticipated DV and SV victimization, perpetration, and bystander nonintervention; (3) SEM and SVM more strongly impact men's DV and SV attitudes and behaviors than women's DV and SV attitudes and behaviors; and (4) preexisting attitudes related to DV and SV and media preferences moderate the relationship between SEM and SVM exposure and DV and SV attitudes and behaviors. Future studies should strive to employ longitudinal and experimental designs, more closely examine the mediators and moderators of SEM and SVM exposure on DV and SV outcomes, focus on the impacts of SEM and SVM that extend beyond men's use of violence against women, and examine the extent to which media literacy programs could be used independently or in conjunction with existing DV and SV prevention programs to enhance effectiveness of these programming efforts.
de Oliveira, Martha Lima; de Melo, Edésio José Tenório; Miguens, Flávio Costa
2016-09-01
Airborne particulate matter (PM) has been included among the most important air pollutants by governmental environment agencies and academy researchers. The use of terrestrial plants for monitoring PM has been widely accepted, particularly when it is coupled with SEM/EDS. Herein, Tillandsia stricta leaves were used as monitors of PM, focusing on a comparative evaluation of Environmental SEM (ESEM) and High-Pressure SEM (HPSEM). In addition, specimens air-dried at formaldehyde atmosphere (AD/FA) were introduced as an SEM procedure. Hydrated specimen observation by ESEM was the best way to get information from T. stricta leaves. If any artifacts were introduced by AD/FA, they were indiscernible from those caused by CPD. Leaf anatomy was always well preserved. PM density was determined on adaxial and abaxial leaf epidermis for each of the SEM proceedings. When compared with ESEM, particle extraction varied from 0 to 20% in air-dried leaves while 23-78% of particles deposited on leaves surfaces were extracted by CPD procedures. ESEM was obviously the best choice over other methods but morphological artifacts increased in function of operation time while HPSEM operation time was without limit. AD/FA avoided the shrinkage observed in the air-dried leaves and particle extraction was low when compared with CPD. Structural and particle density results suggest AD/FA as an important methodological approach to air pollution biomonitoring that can be widely used in all electron microscopy labs. Otherwise, previous PM assessments using terrestrial plants as biomonitors and performed by conventional SEM could have underestimated airborne particulate matter concentration. © 2016 Wiley Periodicals, Inc.
Morgan, Anthony; Ogunbajo, Adedotun; Trent, Maria; Harper, Gary W.; Fortenberry, J. Dennis
2015-01-01
Sexually explicit material (SEM) (including Internet, video, and print) may play a key role in the lives of Black same-sex sexually active youth by providing the only information to learn about sexual development. There is limited school-and/or family-based sex education to serve as models for sexual behaviors for Black youth. We describe the role SEM plays in the sexual development of a sample of Black same-sex attracted (SSA) young adolescent men ages 15–19. Adolescents recruited from clinics, social networking sites, and through snowball sampling were invited to participate in a 90-min, semi-structured qualitative interview. Most participants described using SEM prior to their first same-sex sexual experience. Participants described using SEM primarily for sexual development, including learning about sexual organs and function, the mechanics of same-gender sex, and to negotiate one’s sexual identity. Secondary functions were to determine readiness for sex; to learn about sexual performance, including understanding sexual roles and responsibilities (e.g., “top” or “bottom”); to introduce sexual performance scripts; and to develop models for how sex should feel (e.g., pleasure and pain). Youth also described engaging in sexual behaviors (including condom non-use and/or swallowing ejaculate) that were modeled on SEM. Comprehensive sexuality education programs should be designed to address the unmet needs of young, Black SSA young men, with explicit focus on sexual roles and behaviors that may be inaccurately portrayed and/or involve sexual risk-taking (such as unprotected anal intercourse and swallowing ejaculate) in SEM. This work also calls for development of Internet-based HIV/STI prevention strategies targeting young Black SSA men who maybe accessing SEM. PMID:25677334
Measurement of pattern roughness and local size variation using CD-SEM: current status
NASA Astrophysics Data System (ADS)
Fukuda, Hiroshi; Kawasaki, Takahiro; Kawada, Hiroki; Sakai, Kei; Kato, Takashi; Yamaguchi, Satoru; Ikota, Masami; Momonoi, Yoshinori
2018-03-01
Measurement of line edge roughness (LER) is discussed from four aspects: edge detection, PSD prediction, sampling strategy, and noise mitigation, and general guidelines and practical solutions for LER measurement today are introduced. Advanced edge detection algorithms such as wave-matching method are shown effective for robustly detecting edges from low SNR images, while conventional algorithm with weak filtering is still effective in suppressing SEM noise and aliasing. Advanced PSD prediction method such as multi-taper method is effective in suppressing sampling noise within a line edge to analyze, while number of lines is still required for suppressing line to line variation. Two types of SEM noise mitigation methods, "apparent noise floor" subtraction method and LER-noise decomposition using regression analysis are verified to successfully mitigate SEM noise from PSD curves. These results are extended to LCDU measurement to clarify the impact of SEM noise and sampling noise on LCDU.
Connected component analysis of review-SEM images for sub-10nm node process verification
NASA Astrophysics Data System (ADS)
Halder, Sandip; Leray, Philippe; Sah, Kaushik; Cross, Andrew; Parisi, Paolo
2017-03-01
Analysis of hotspots is becoming more and more critical as we scale from node to node. To define true process windows at sub-14 nm technology nodes, often defect inspections are being included to weed out design weak spots (often referred to as hotspots). Defect inspection sub 28 nm nodes is a two pass process. Defect locations identified by optical inspection tools need to be reviewed by review-SEM's to understand exactly which feature is failing in the region flagged by the optical tool. The images grabbed by the review-SEM tool are used for classification but rarely for quantification. The goal of this paper is to see if the thousands of review-SEM images which are existing can be used for quantification and further analysis. More specifically we address the SEM quantification problem with connected component analysis.
NASA Astrophysics Data System (ADS)
Fernandes, F. C. R.; Sawant, H. S.; Cecatto, J. R.; Caracini, A. G.; Vats, H. O.; Karlický, M.; Meszarosova, H.
2003-08-01
Em 06 de junho de 2000 (~15: 00-17: 00 UT), o Brazilian Solar Spectroscope (BSS) registrou uma explosão solar intensa no intervalo de freqüência de (1000-2000) MHz, com alta resolução temporal (100 ms) e espectral (5 MHz). A atividade solar relacionada a esta explosão associada à região ativa (AR) 9026 e classificada como X2.3 foi grande. O Ondrejov Observatory registrou rádio emissões até 4,5 GHz. O satélite SOHO registrou uma série de erupções solares, incluindo uma Ejeção de Massa Coronal (CME) tipo "full-halo" (~15: 54 UT). Explosões tipo II/IV também foram registradas. Na faixa de ondas decimétricas, este evento apresentou dois picos distintos (~15: 21 UT e ~16: 42 UT). O primeiro pico coincide com a explosão registrada em raios-X moles (GOES) e em raios-X duros (Yohkoh). Os espectros dinâmicos com alta resolução do BSS revelaram várias estruturas finas, principalmente emissões tipo "zebra" e "fibra", rádio pulsações, emissões tipo III e do único caso de emissões "zebra" harmônicas observado na faixa decimétrica. Neste trabalho, analisamos a evolução temporal e o comportamento global do evento de 06 de junho de 2000, com ênfase na identificação e associação da ocorrência de cada tipo de estrutura fina registrada em rádio com cada etapa da explosão. Resultados preliminares mostraram que, na fase pré-flare, as estruturas finas apresentaram taxa de deriva negativa (~ 70-190 MHz/s). As emissões tipo "zebra" concentram-se na fase de descida do primeiro pico impulsivo e na de subida do segundo pico. Enquanto que as emissões tipo "fibra" ocorrem em ambas fases, mas preferivelmente durante a fase de descida. Os resultados serão apresentados e discutidos.
Structural Equation Modeling in Language Testing and Learning Research: A Review
ERIC Educational Resources Information Center
In'nami, Yo; Koizumi, Rie
2011-01-01
Despite the recent increase of structural equation modeling (SEM) in language testing and learning research and Kunnan's (1998) call for the proper use of SEM to produce useful findings, there seem to be no reviews about how SEM is applied in these areas or about the extent to which the current application accords with appropriate practices. To…
ERIC Educational Resources Information Center
Fenske, Robert H.; Porter, John D.; DuBrock, Caryl P.
2000-01-01
This longitudinal study followed four consecutive freshmen cohorts at a large urban public university. Found science, engineering, and mathematics (SEM) students persisted and graduated at higher rates than non-SEM majors. Gift aid for SEM majors was more likely to be merit-based than need-based. Women, but not underrepresented minorities or needy…
ERIC Educational Resources Information Center
Seo, Hyojeong; Little, Todd D.; Shogren, Karrie A.; Lang, Kyle M.
2016-01-01
Structural equation modeling (SEM) is a powerful and flexible analytic tool to model latent constructs and their relations with observed variables and other constructs. SEM applications offer advantages over classical models in dealing with statistical assumptions and in adjusting for measurement error. So far, however, SEM has not been fully used…
Serpentine End Matching: A Test of Visual Perception
Bruce G. Hansen; Charles J. Gatchell
1978-01-01
In tests of gross perception of Serpentine end matched (Sem) joints in oak and cherry display panels, there were no significant differences between the number of times the non-Sem panels were chosen and the number of these selections that could be attributed to chance. Results of separate tests of sensitivity of perception of Sem joints showed that the most conspicuous...
ERIC Educational Resources Information Center
Ng, Peggy; Galbraith, Craig
2016-01-01
The purpose of this study is to examine how the dimensions of strategic enrolment management (SEM) tie to the success metrics in the area of enrolment, retention and graduation from senior and programme management perspectives of a self-financed institution in Hong Kong. The literature on SEM has demonstrated that managing enrolment is a global…
Scanning Electron Microscopy (SEM) Procedure for HE Powders on a Zeiss Sigma HD VP SEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaka, F.
This method describes the characterization of inert and HE materials by the Zeiss Sigma HD VP field emission Scanning Electron Microscope (SEM). The SEM uses an accelerated electron beam to generate high-magnification images of explosives and other materials. It is fitted with five detectors (SE, Inlens, STEM, VPSE, HDBSD) to enable imaging of the sample via different secondary electron signatures, angles, and energies. In addition to imaging through electron detection, the microscope is also fitted with two Oxford Instrument Energy Dispersive Spectrometer (EDS) 80 mm detectors to generate elemental constituent spectra and two-dimensional maps of the material being scanned.
Improvement of CD-SEM mark position measurement accuracy
NASA Astrophysics Data System (ADS)
Kasa, Kentaro; Fukuhara, Kazuya
2014-04-01
CD-SEM is now attracting attention as a tool that can accurately measure positional error of device patterns. However, the measurement accuracy can get worse due to pattern asymmetry as in the case of image based overlay (IBO) and diffraction based overlay (DBO). For IBO and DBO, a way of correcting the inaccuracy arising from measurement patterns was suggested. For CD-SEM, although a way of correcting CD bias was proposed, it has not been argued how to correct the inaccuracy arising from pattern asymmetry using CD-SEM. In this study we will propose how to quantify and correct the measurement inaccuracy affected by pattern asymmetry.
3DSEM++: Adaptive and intelligent 3D SEM surface reconstruction.
Tafti, Ahmad P; Holz, Jessica D; Baghaie, Ahmadreza; Owen, Heather A; He, Max M; Yu, Zeyun
2016-08-01
Structural analysis of microscopic objects is a longstanding topic in several scientific disciplines, such as biological, mechanical, and materials sciences. The scanning electron microscope (SEM), as a promising imaging equipment has been around for decades to determine the surface properties (e.g., compositions or geometries) of specimens by achieving increased magnification, contrast, and resolution greater than one nanometer. Whereas SEM micrographs still remain two-dimensional (2D), many research and educational questions truly require knowledge and facts about their three-dimensional (3D) structures. 3D surface reconstruction from SEM images leads to remarkable understanding of microscopic surfaces, allowing informative and qualitative visualization of the samples being investigated. In this contribution, we integrate several computational technologies including machine learning, contrario methodology, and epipolar geometry to design and develop a novel and efficient method called 3DSEM++ for multi-view 3D SEM surface reconstruction in an adaptive and intelligent fashion. The experiments which have been performed on real and synthetic data assert the approach is able to reach a significant precision to both SEM extrinsic calibration and its 3D surface modeling. Copyright © 2016 Elsevier Ltd. All rights reserved.
Recent advances in 3D SEM surface reconstruction.
Tafti, Ahmad P; Kirkpatrick, Andrew B; Alavi, Zahrasadat; Owen, Heather A; Yu, Zeyun
2015-11-01
The scanning electron microscope (SEM), as one of the most commonly used instruments in biology and material sciences, employs electrons instead of light to determine the surface properties of specimens. However, the SEM micrographs still remain 2D images. To effectively measure and visualize the surface attributes, we need to restore the 3D shape model from the SEM images. 3D surface reconstruction is a longstanding topic in microscopy vision as it offers quantitative and visual information for a variety of applications consisting medicine, pharmacology, chemistry, and mechanics. In this paper, we attempt to explain the expanding body of the work in this area, including a discussion of recent techniques and algorithms. With the present work, we also enhance the reliability, accuracy, and speed of 3D SEM surface reconstruction by designing and developing an optimized multi-view framework. We then consider several real-world experiments as well as synthetic data to examine the qualitative and quantitative attributes of our proposed framework. Furthermore, we present a taxonomy of 3D SEM surface reconstruction approaches and address several challenging issues as part of our future work. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hasegawa, Tomoka; Yamamoto, Tomomaya; Hongo, Hiromi; Qiu, Zixuan; Abe, Miki; Kanesaki, Takuma; Tanaka, Kawori; Endo, Takashi; de Freitas, Paulo Henrique Luiz; Li, Minqi; Amizuka, Norio
2018-04-01
The aim of this study is to demonstrate the application of focused ion beam-scanning electron microscopy, FIB-SEM for revealing the three-dimensional features of osteocytic cytoplasmic processes in metaphyseal (immature) and diaphyseal (mature) trabeculae. Tibiae of eight-week-old male mice were fixed with aldehyde solution, and treated with block staining prior to FIB-SEM observation. While two-dimensional backscattered SEM images showed osteocytes' cytoplasmic processes in a fragmented fashion, three-dimensional reconstructions of FIB-SEM images demonstrated that osteocytes in primary metaphyseal trabeculae extended their cytoplasmic processes randomly, thus maintaining contact with neighboring osteocytes and osteoblasts. In contrast, diaphyseal osteocytes extended thin cytoplasmic processes from their cell bodies, which ran perpendicular to the bone surface. In addition, these osteocytes featured thick processes that branched into thinner, transverse cytoplasmic processes; at some point, however, these transverse processes bend at a right angle to run perpendicular to the bone surface. Osteoblasts also possessed thicker cytoplasmic processes that branched off as thinner processes, which then connected with cytoplasmic processes of neighboring osteocytes. Thus, FIB-SEM is a useful technology for visualizing the three-dimensional structures of osteocytes and their cytoplasmic processes.
Hortolà, Policarp
2015-12-01
Some archaeological or ethnographic specimens are unavailable for direct examination using a scanning electron microscope (SEM) due to methodological obstacles or legal issues. In order to assess the feasibility of using SEM synthetic replicas for the identification of bloodstains (BSs) via morphology of red blood cells (RBCs), three fragments of different natural raw material (inorganic, stone; plant, wood; animal, shell) were smeared with peripheral human blood. Afterwards, molds and casts of the bloodstained areas were made using vinyl polysiloxane (VPS) silicone impression and polyurethane (PU) resin casting material, respectively. Then, the original samples and the resulting casts were coated with gold and examined in secondary-electron mode using a high-vacuum SEM. Results suggest that PU resin casts obtained from VPS silicone molds can preserve RBC morphology in BSs, and consequently that synthetic replicas are feasible for SEM identification of BSs on cultural heritage specimens made of natural raw materials. Although the focus of this study was on BSs, the method reported in this paper may be applicable to organic residues other than blood, as well as to the surface of other specimens when, for any reason, the original is unavailable for an SEM.
In Situ Characterization of Boehmite Particles in Water Using Liquid SEM.
Yao, Juan; Arey, Bruce W; Yang, Li; Zhang, Fei; Komorek, Rachel; Chun, Jaehun; Yu, Xiao-Ying
2017-09-27
In situ imaging and elemental analysis of boehmite (AlOOH) particles in water is realized using the System for Analysis at the Liquid Vacuum Interface (SALVI) and Scanning Electron Microscopy (SEM). This paper describes the method and key steps in integrating the vacuum compatible SAVLI to SEM and obtaining secondary electron (SE) images of particles in liquid in high vacuum. Energy dispersive x-ray spectroscopy (EDX) is used to obtain elemental analysis of particles in liquid and control samples including deionized (DI) water only and an empty channel as well. Synthesized boehmite (AlOOH) particles suspended in liquid are used as a model in the liquid SEM illustration. The results demonstrate that the particles can be imaged in the SE mode with good resolution (i.e., 400 nm). The AlOOH EDX spectrum shows significant signal from the aluminum (Al) when compared with the DI water and the empty channel control. In situ liquid SEM is a powerful technique to study particles in liquid with many exciting applications. This procedure aims to provide technical know-how in order to conduct liquid SEM imaging and EDX analysis using SALVI and to reduce potential pitfalls when using this approach.
Multidimensionally encoded magnetic resonance imaging.
Lin, Fa-Hsuan
2013-07-01
Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled. Copyright © 2012 Wiley Periodicals, Inc.
Structural neuroanatomy of tinnitus and hyperacusis in semantic dementia.
Mahoney, Colin J; Rohrer, Jonathan D; Goll, Johanna C; Fox, Nick C; Rossor, Martin N; Warren, Jason D
2011-11-01
Tinnitus and hyperacusis are common symptoms of excessive auditory perception in the general population; however, their anatomical substrates and disease associations continue to be defined. with semantic dementia (SemD) frequently report tinnitus and hyperacusis but the significance and basis for these symptoms have not been elucidated. 43 patients with a diagnosis of SemD attending a specialist cognitive disorders clinic were retrospectively studied. 14 patients (32% of the cohort) reported at least moderately severe chronic auditory symptoms: seven had tinnitus and a further seven had hyperacusis, and all had brain MRI while symptomatic. MRI data from SemD patients with and without auditory symptoms were compared using voxel based morphometry in order to identify neuroanatomical associations of tinnitus and hyperacusis. Compared with SemD patients with no history of auditory symptoms, patients with tinnitus or hyperacusis had relative preservation of grey matter in the posterior superior temporal lobe and reduced grey matter in the orbitofrontal cortex and medial geniculate nucleus. Tinnitus and hyperacusis may be a significant issue in SemD. Neuroanatomical evidence in SemD supports previous work implicating a distributed cortico-subcortical auditory and limbic network in the pathogenesis of these abnormal auditory percepts.
Environmental scanning electron microscope imaging examples related to particle analysis.
Wight, S A; Zeissler, C J
1993-08-01
This work provides examples of some of the imaging capabilities of environmental scanning electron microscopy applied to easily charged samples relevant to particle analysis. Environmental SEM (also referred to as high pressure or low vacuum SEM) can address uncoated samples that are known to be difficult to image. Most of these specimens are difficult to image by conventional SEM even when coated with a conductive layer. Another area where environmental SEM is particularly applicable is for specimens not compatible with high vacuum, such as volatile specimens. Samples from which images were obtained that otherwise may not have been possible by conventional methods included fly ash particles on an oiled plastic membrane impactor substrate, a one micrometer diameter fiber mounted on the end of a wire, uranium oxide particles embedded in oil-bearing cellulose nitrate, teflon and polycarbonate filter materials with collected air particulate matter, polystyrene latex spheres on cellulosic filter paper, polystyrene latex spheres "loosely" sitting on a glass slide, and subsurface tracks in an etched nuclear track-etch detector. Surface charging problems experienced in high vacuum SEMs are virtually eliminated in the low vacuum SEM, extending imaging capabilities to samples previously difficult to use or incompatible with conventional methods.
Tomić, Ivan; Burić, Jakov; Štulhofer, Aleksandar
2017-10-25
The use of sexually explicit material (SEM) has become a part of adolescent sexual socialization, at least in the Western world. Adolescent and young people's SEM use has been associated with risky sexual behaviors, which has recently resulted in policy debates about restricting access to SEM. Such development seems to suggest a crisis of the preventive role of parental oversight. Based on the Differential Susceptibility to Media Effects Model, this study assessed the role of parental monitoring in the context of adolescent vulnerability to SEM-associated risky or potentially adverse outcomes (sexual activity, sexual aggressiveness, and sexting). Using an online sample of Croatian 16-year-olds (N = 1265) and structural equation modeling approach, parental monitoring was found consistently and negatively related to the problematic behavioral outcomes, regardless of participants' gender. While SEM use was related to sexual experience and sexting, higher levels of parental monitoring were associated with less frequent SEM use and lower acceptance of sexual permissiveness. Despite parents' fears about losing the ability to monitor their adolescent children's lives in the Internet era, there is evidence that parental engagement remains an important protective factor.
Sun, Cheng; Müller, Erich; Meffert, Matthias; Gerthsen, Dagmar
2018-04-01
Transmission electron microscopy (TEM) with low-energy electrons has been recognized as an important addition to the family of electron microscopies as it may avoid knock-on damage and increase the contrast of weakly scattering objects. Scanning electron microscopes (SEMs) are well suited for low-energy electron microscopy with maximum electron energies of 30 keV, but they are mainly used for topography imaging of bulk samples. Implementation of a scanning transmission electron microscopy (STEM) detector and a charge-coupled-device camera for the acquisition of on-axis transmission electron diffraction (TED) patterns, in combination with recent resolution improvements, make SEMs highly interesting for structure analysis of some electron-transparent specimens which are traditionally investigated by TEM. A new aspect is correlative SEM, STEM, and TED imaging from the same specimen region in a SEM which leads to a wealth of information. Simultaneous image acquisition gives information on surface topography, inner structure including crystal defects and qualitative material contrast. Lattice-fringe resolution is obtained in bright-field STEM imaging. The benefits of correlative SEM/STEM/TED imaging in a SEM are exemplified by structure analyses from representative sample classes such as nanoparticulates and bulk materials.
Rheeder, P; Stolk, R P; Veenhouwer, J F; Grobbee, D E
2002-08-01
To examine the association between measures of obesity and features of the metabolic syndrome in treated black female hypertensive subjects. Cross-sectional study. An urban primary health care centre in Mamelodi, Pretoria. Women with hypertension and without known diabetes mellitus or secondary causes of hypertension. In total 124 women participated, with a mean age of 56.9 years (standard deviation (SD) 11.0) and mean body mass index (BMI) of 34.1 kg/m2 (SD 8.1). Blood pressure, glucose, insulin and lipid levels. Waist circumference and waist-hip ratio were more strongly associated with insulin, uric acid, glucose and triglycerides than was BMI. Statistically significant associations were found between waist circumference and low high-density lipoprotein HDL cholesterol (standardised regression coefficient -0.006, standard error of the mean (SEM) 0.002), log triglycerides (0.007, SEM 0.003), uric acid (0.002, SEM 0.001) and log insulin (0.012, SEM 0.003). BMI was only significantly associated with uric acid (0.002, SEM 0.002) and log insulin (0.009, SEM 0.004). In a group of black hypertensive women measures of central obesity were more strongly associated with components of the metabolic syndrome than BMI.
Lo, Te-Wen; Bennett, Daniel C; Goodman, S Jay; Stern, Michael J
2010-06-01
The components of receptor tyrosine kinase signaling complexes help to define the specificity of the effects of their activation. The Caenorhabditis elegans fibroblast growth factor receptor (FGFR), EGL-15, regulates a number of processes, including sex myoblast (SM) migration guidance and fluid homeostasis, both of which require a Grb2/Sos/Ras cassette of signaling components. Here we show that SEM-5/Grb2 can bind directly to EGL-15 to mediate SM chemoattraction. A yeast two-hybrid screen identified SEM-5 as able to interact with the carboxy-terminal domain (CTD) of EGL-15, a domain that is specifically required for SM chemoattraction. This interaction requires the SEM-5 SH2-binding motifs present in the CTD (Y(1009) and Y(1087)), and these sites are required for the CTD role of EGL-15 in SM chemoattraction. SEM-5, but not the SEM-5 binding sites located in the CTD, is required for the fluid homeostasis function of EGL-15, indicating that SEM-5 can link to EGL-15 through an alternative mechanism. The multi-substrate adaptor protein FRS2 serves to link vertebrate FGFRs to Grb2. In C. elegans, an FRS2-like gene, rog-1, functions upstream of a Ras/MAPK pathway for oocyte maturation but is not required for EGL-15 function. Thus, unlike the vertebrate FGFRs, which require the multi-substrate adaptor FRS2 to recruit Grb2, EGL-15 can recruit SEM-5/Grb2 directly.
Kawahara, Yohei; Terada, Itsuro; Terai, Shiro; Watanabe, Toshifumi; Amaya, Koji; Yamamoto, Seiichi; Kaji, Masahide; Maeda, Kiichi; Shimizu, Koichi
2015-11-01
In our institution, placement of a self-expanding metallic stent (SEMS) for obstructive colorectal cancer to avoid emergency operations, namely as a bridge to surgery (BTS), was introduced in April 2012. Here, we assess the efficacy and safety of pre-operative SEMS placement for treatment of Stage Ⅳ obstructive colorectal cancer. We analyzed a total of 44 cases of Stage Ⅳ colorectal cancer, which consisted of 13 obstructive cases that were surgically resected following SEMS placement as BTS (BTS group), and 31 cases that were resected in elective operations without pre-operative SEMS placement (Ope group), from April 2012 to August 2014. None of the patients had any adverse events during the SEMS procedure or after SEMS placement, and all patients of BTS group could undergo the planned operations after sufficient decompression. In the postoperative period, 1 patient of BTS group (7.7%) had anastomosis bleeding, but no other complications, including anastomosis leakage, were observed in BTS group. However more progressive primary tumors were resected in BTS group (p=0.0115), there were no significant differences for post-operative course between the 2 groups; this indicated avoiding high-risk emergency operations contributed to adequate short-term outcomes in BTS group comparable to those in Ope group. SEMS placement as BTS could be performed safely for Stage Ⅳ obstructive colorectal cancer cases, and was 1 of the effective strategies for local treatment.
Kupek, Emil
2006-03-15
Structural equation modelling (SEM) has been increasingly used in medical statistics for solving a system of related regression equations. However, a great obstacle for its wider use has been its difficulty in handling categorical variables within the framework of generalised linear models. A large data set with a known structure among two related outcomes and three independent variables was generated to investigate the use of Yule's transformation of odds ratio (OR) into Q-metric by (OR-1)/(OR+1) to approximate Pearson's correlation coefficients between binary variables whose covariance structure can be further analysed by SEM. Percent of correctly classified events and non-events was compared with the classification obtained by logistic regression. The performance of SEM based on Q-metric was also checked on a small (N = 100) random sample of the data generated and on a real data set. SEM successfully recovered the generated model structure. SEM of real data suggested a significant influence of a latent confounding variable which would have not been detectable by standard logistic regression. SEM classification performance was broadly similar to that of the logistic regression. The analysis of binary data can be greatly enhanced by Yule's transformation of odds ratios into estimated correlation matrix that can be further analysed by SEM. The interpretation of results is aided by expressing them as odds ratios which are the most frequently used measure of effect in medical statistics.
Enrichment Mechanism of Semiconducting Single-walled Carbon Nanotubes by Surfactant Amines
Ju, Sang-Yong; Utz, Marcel; Papadimitrakopoulos, Fotios
2009-01-01
Utilization of single-walled carbon nanotubes (SWNTs) in high-end applications hinges on separating metallic (met-) from semiconducting (sem-) SWNTs. Surfactant amines, like octadecylamine (ODA) have proven instrumental for the selective extraction of sem-SWNTs from tetrahydrofuran (THF) nanotube suspensions. The chemical shift differences along the tail of an asymmetric, diacetylenic surfactant amine were used to probe the molecular dynamics in the presence and absence of nanotubes via NMR. The results suggest that the surfactant amine head is firmly immobilized onto the nanotube surface together with acidic water, while the aliphatic tail progressively gains larger mobility as it gets farther from the SWNT. X-ray and high-resolution TEM studies indicate that the sem-enriched sample is populated mainly by small nanotube bundles containing ca. three SWNTs. Molecular simulations in conjunction with previously determined HNO3/H2SO4 oxidation depths for met- and sem-SWNTs indicate that the strong pinning of the amine surfactants on the sem-enriched SWNTs bundles is a result of a well-ordered arrangement of nitrate/amine salts separated with a monomolecular layer of H2O. Such continuous 2D arrangement of nitrate/amine salts shields the local environment adjacent to sem-enriched SWNTs bundles and maintains an acidic pH that preserves nanotube oxidation (i.e. SWNTn+). This, in turn, results in strong interactions with charge-balancing NO3- counter ions that through their association with neutralized surfactant amines provide effective THF dispersion and consequent sem-enrichment. PMID:19397291
Han, Yimo; Nguyen, Kayla X; Ogawa, Yui; Park, Jiwoong; Muller, David A
2016-12-14
Scanning electron microscopes (SEMs) require a high vacuum environment to generate and shape an electron beam for imaging; however, the vacuum conditions greatly limit the nature of specimens that can be examined. From a purely scattering physics perspective, it is not necessary to place the specimen inside the vacuum chamber-the mean free paths (MFPs) for electron scattering in air at typical SEM beam voltages are 50-100 μm. This is the idea behind the airSEM, which removes the specimen vacuum chamber from the SEM and places the sample in air. The thickness of the gas layer is less than a MFP from an electron-transparent window to preserve the shape and resolution of the incident beam, resulting in comparable imaging quality to an all-vacuum SEM. Present silicon nitride windows scatter far more strongly than the air gap and are currently the contrast and resolution limiting factor in the airSEM. Graphene windows have been used previously to wrap or seal samples in vacuum for imaging. Here we demonstrate the use of a robust bilayer graphene window for sealing the electron optics from the room environment, providing an electron transparent window with only a 2% drop in contrast. There is a 5-fold-increase in signal/noise ratio for imaging compared to multi-MFP-thick silicon nitride windows, enabling high contrast in backscattered, transmission, and surface imaging modes for the new airSEM geometry.
Kroboth, P D; Folan, M M; Bauer, K S; Tullock, W; Wright, C E; Sweeney, J A
1998-04-01
The purpose of this study was to determine whether short-term tolerance develops to GABA-agonist-induced changes in saccadic eye movements (SEMs), and whether the time course for GABA-agonist induced onset and offset of impairment is similar for SEMs and for psychomotor function. An additional goal was to determine whether there are differences in sensitivity between SEMs and psychomotor function. Six healthy volunteers participated in this balanced double-blind, three-way crossover, single-dose study of placebo and two different dosage forms of the GABA-agonist alprazolam: a rapidly absorbed oral 1.5-mg compressed tablet (CT) and a 3.0-mg sustained release (SR) tablet. Treatments were separated by a 7-day washout period. Peak concentrations did not differ between CT and SR treatments, although area under the concentration-time curve (AUC) of alprazolam was greater after administration of SR than after CT, because plateau concentrations were attained after SR. Both SEM and psychomotor tests showed time-dependent responses consistent with the development of tolerance. SEMs discriminated the differences in rate of drug input of the CT and SR formulations, with impairment evident at low concentrations during absorption. SEM impairment also persisted longer than did psychomotor impairment. Peak saccade velocity is a more sensitive indicator of pharmacologic effects mediated by the GABA-benzodiazepine receptor complex than are psychomotor responses. This is probably the result of the very high GABA dependency of SEMs, along with their limited sensitivity to motivation.
ERIC Educational Resources Information Center
Pan, Tianshu; Yin, Yue
2012-01-01
In the discussion of mean square difference (MSD) and standard error of measurement (SEM), Barchard (2012) concluded that the MSD between 2 sets of test scores is greater than 2(SEM)[superscript 2] and SEM underestimates the score difference between 2 tests when the 2 tests are not parallel. This conclusion has limitations for 2 reasons. First,…
ERIC Educational Resources Information Center
Seo, Hyojeong; Little, Todd D.; Shogren, Karrie A.; Lang, Kyle M.
2016-01-01
Structural equation modeling (SEM) is a powerful and flexible analytic tool to model latent constructs and their relations with observed variables and other constructs. SEM applications offer advantages over classical models in dealing with statistical assumptions and in adjusting for measurement error. So far, however, SEM has not been fully used…
Downing, Martin J; Schrimshaw, Eric W; Scheinmann, Roberta; Antebi-Gruszka, Nadav; Hirshfield, Sabina
2017-08-01
Advances in production and distribution of sexually explicit media (SEM) online have resulted in widespread use among men. Limited research has compared contexts of use and behaviors viewed in Internet SEM by sexual identity. The current study examined differences in recent SEM use (past 6 months) by sexual identity among an ethnically diverse sample of 821 men who completed an online survey in 2015. Both gay and bisexual men reported significantly more frequent use of Internet SEM compared to heterosexual men. Although most participants reported viewing SEM at home (on a computer, tablet, or smartphone), significantly more gay men reported SEM use at a sex party or commercial sex venue than either heterosexual or bisexual men. Sexual identity predicted viewing of high-risk and protective behaviors in separate logistic regression models. Specifically, compared to heterosexual men, gay and bisexual men had increased odds of viewing condomless anal sex (gay OR 5.20, 95 % CI 3.35-8.09; bisexual OR 3.99, 95 % CI 2.24-7.10) and anal sex with a condom (gay OR 3.93, 95 % CI 2.64-5.83; bisexual OR 4.59, 95 % CI 2.78-7.57). Compared to gay men, heterosexual and bisexual men had increased odds of viewing condomless vaginal sex (heterosexual OR 27.08, 95 % CI 15.25-48.07; bisexual OR 5.59, 95 % CI 3.81-8.21) and vaginal sex with a condom (heterosexual OR 7.90, 95 % CI 5.19-12.03; bisexual OR 4.97, 95 % CI 3.32-7.44). There was also evidence of identity discrepant SEM viewing as 20.7 % of heterosexual-identified men reported viewing male same-sex behavior and 55.0 % of gay-identified men reported viewing heterosexual behavior. Findings suggest the importance of assessing SEM use across media types and contexts and have implications for research to address the potential influence of SEM on sexual behavior (e.g., investigate associations between viewing condomless vaginal sex and engaging in high-risk encounters with female partners).
Nyambe, Anayawa; Van Hal, Guido; Kampen, Jarl K
2016-11-17
Vaccination and screening are forms of primary and secondary prevention methods. These methods are recommended for controlling the spread of a vast number of diseases and conditions. To determine the most effective preventive methods to be used by a society, multi-level models have shown to be more effective than models that focus solely on individual level characteristics. The Social Ecological Model (SEM) and the Theory of Triadic Influence (TTI) are such models. The purpose of this systematic review was to identify main differences and similarities of SEM and TTI regarding screening and vaccination in order to prepare potentially successful prevention programs for practice. A systematic review was conducted. Separate literature searches were performed during January and February 2015 using Medline, Ovid, Proquest, PubMed, University of Antwerp Discovery Service and Web of Science, for articles that apply the SEM and TTI. A Data Extraction Form with mostly closed-end questions was developed to assist with data extraction. Aggregate descriptive statistics were utilized to summarize the general characteristics of the SEM and TTI as documented in the scientific literature. A total of 290 potentially relevant articles referencing the SEM were found. As for the TTI, a total of 131 potentially relevant articles were found. After strict evaluation for inclusion and exclusion criteria, 40 SEM studies and 46 TTI studies were included in the systematic review. The SEM and TTI are theoretical frameworks that share many theoretical concepts and are relevant for several types of health behaviors. However, they differ in the structure of the model, and in how the variables are thought to interact with each other, the TTI being a matrix while the SEM has a ring structure. The main difference consists of the division of the TTI into levels of causation (ultimate, distal and proximal) which are not considered within the levels of the SEM. It was further found that in the articles studied in this systematic review, both models are often considered effective, while the empirical basis of these (and other) conclusions reached by their authors is in many cases unclear or incompletely specified.
Coté, Gregory A.; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K.; Elmunzer, B. Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D.; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart
2017-01-01
IMPORTANCE Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. OBJECTIVE To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. DESIGN, SETTING, AND PARTICIPANTS Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. INTERVENTIONS Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. MAIN OUTCOMES AND MEASURES Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of −15%. RESULTS There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, −3.0% to ∞; P < .001). Given the prespecified noninferiority margin of −15%, the null hypothesis that cSEMS is less effective than plastic stents was rejected. The mean number of ERCPs to achieve resolution was lower for cSEMS (2.14) vs plastic (3.24; mean difference, 1.10; 95% CI, 0.74 to 1.46; P < .001). CONCLUSIONS AND RELEVANCE Among patients with benign biliary strictures and a bile duct diameter 6 mm or more in whom the covered metallic stent would not overlap the cystic duct, cSEMS were not inferior to multiple plastic stents after 12 months in achieving stricture resolution. Metallic stents should be considered an appropriate option in patients such as these. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01221311 PMID:27002446
Application of the SEM to the measurement of solar cell parameters
NASA Technical Reports Server (NTRS)
Weizer, V. G.; Andrews, C. W.
1977-01-01
Techniques are described which make use of the SEM to measure the minority carrier diffusion length and the metallurgical junction depth in silicon solar cells. The former technique permits the measurement of the true bulk diffusion length through the application of highly doped field layers to the back surfaces of the cells being investigated. It is shown that the secondary emission contrast observed in the SEM on a reverse-biased diode can depict the location of the metallurgical junction if the diode has been prepared with the proper beveled geometry. The SEM provides the required contrast and the option of high magnification, permitting the measurement of extremely shallow junction depths.
A new way of measuring wiggling pattern in SADP for 3D NAND technology
NASA Astrophysics Data System (ADS)
Mi, Jian; Chen, Ziqi; Tu, Li Ming; Mao, Xiaoming; Liu, Gong Cai; Kawada, Hiroki
2018-03-01
A new metrology method of quantitatively measuring wiggling patterns in a Self-Aligned Double Patterning (SADP) process for 2D NAND technology has been developed with a CD-SEM metrology program on images from a Review-SEM system. The metrology program provided accurate modeling of various wiggling patterns. The Review-SEM system provided a-few-micrometer-wide Field of View (FOV), which exceeds precision-guaranteed FOV of a conventional CD-SEM. The result has been effectively verified by visual inspection on vertically compressed images compared with Wiggling Index from this new method. A best-known method (BKM) system has been developed with connected HW and SW to automatically measure wiggling patterns.
Oho, Eisaku; Suzuki, Kazuhiko; Yamazaki, Sadao
2007-01-01
The quality of the image signal obtained from the environmental secondary electron detector (ESED) employed in a variable pressure (VP) SEM can be dramatically improved by using helium gas. The signal-to-noise ratio (SNR) increases gradually in the range of the pressures that can be used in our modified SEM. This method is especially useful in low-voltage VP SEM as well as in a variety of SEM operating conditions, because helium gas can more or less maintain the amount of unscattered primary electrons. In order to measure the SNR precisely, a digital scan generator system for obtaining two images with identical views is employed as a precondition.
Tian, Chenxi; Shi, Herong; Colledge, Clark; Stern, Michael; Waterston, Robert; Liu, Jun
2011-01-01
The proper development of multicellular organisms requires precise regulation and coordination of cell fate specification, cell proliferation and differentiation. Abnormal regulation and coordination of these processes could lead to disease, including cancer. We have examined the function of the sole C. elegans SoxC protein, SEM-2, in the M lineage, which produces the postembryonic mesoderm. We found that SEM-2/SoxC is both necessary and sufficient to promote a proliferating blast cell fate, the sex myoblast fate, over a differentiated striated bodywall muscle fate. A number of factors control the specific expression of sem-2 in the sex myoblast precursors and their descendants. This includes direct control of sem-2 expression by a Hox-PBC complex. The crucial nature of the HOX/PBC factors in directly enhancing expression of this proliferative factor in the C. elegans M lineage suggests a possible more general link between Hox-PBC factors and SoxC proteins in regulating cell proliferation. PMID:21307099
Yaghoubi, Ali; Pourjam, Ebrahim; Álvarez-Ortega, Sergio; Liébanas, Gracia; Atighi, Mohammad Reza; Pedram, Majid
2016-09-01
Discopersicus iranicus n. gen., n. comb., previously described from Iran as a new species under the genus Discotylenchus , is illustrated using light microscope and scanning electron microscope (SEM) observations and further studied using molecular characters. SEM studies revealed the newly proposed genus has oblique amphidial apertures on the lateral sides of the lip region. SEM images are also provided for two species of Discotylenchus , namely D. discretus and D. brevicaudatus , as the first SEM study of the genus . These results confirmed longitudinal amphidial aperture type on lateral sides of the lip region in genus Discotylenchus , as noted by Siddiqi while erecting the genus with D. discretus as the type species . Molecular phylogenetic analyses using partial small subunit (SSU) and large subunit (LSU) rDNA sequences revealed the affinity of the genus Discopersicus n. gen. with members of the subfamily Boleodorinae, as supported by morphological characters (mainly, the oblique amphidial opening).
Silane surface modification for improved bioadhesion of esophageal stents
NASA Astrophysics Data System (ADS)
Karakoy, Mert; Gultepe, Evin; Pandey, Shivendra; Khashab, Mouen A.; Gracias, David H.
2014-08-01
Stent migration occurs in 10-40% of patients who undergo placement of esophageal stents, with higher migration rates seen in those treated for benign esophageal disorders. This remains a major drawback of esophageal stent therapy. In this paper, we propose a new surface modification method to increase the adhesion between self-expandable metallic stents (SEMS) and tissue while preserving their removability. Taking advantage of the well-known affinity between epoxide and amine terminated silane coupling agents with amine and carboxyl groups that are abundant in proteins and related molecules in the human body; we modified the surfaces of silicone coated esophageal SEMS with these adhesive self-assembled monolayers (SAMs). We utilized vapor phase silanization to modify the surfaces of different substrates including PDMS strips and SEMS, and measured the force required to slide these substrates on a tissue piece. Our results suggest that surface modification of esophageal SEMS via covalent attachment of protein-binding coupling agents improves adhesion to tissue and could offer a solution to reduce SEMS migration while preserving their removability.
Human cardiac telocytes: 3D imaging by FIB-SEM tomography
Cretoiu, D; Hummel, E; Zimmermann, H; Gherghiceanu, M; Popescu, L M
2014-01-01
Telocyte (TC) is a newly identified type of cell in the cardiac interstitium (www.telocytes.com). TCs are described by classical transmission electron microscopy as cells with very thin and long telopodes (Tps; cellular prolongations) having podoms (dilations) and podomers (very thin segments). TCs’ three-dimensional (3D) morphology is still unknown. Cardiac TCs seem to be particularly involved in long and short distance intercellular signalling and, therefore, their 3D architecture is important for understanding their spatial connections. Using focused ion beam scanning electron microscopy (FIB-SEM) we show, for the first time, the whole ultrastructural anatomy of cardiac TCs. 3D reconstruction of cardiac TCs by FIB-SEM tomography confirms that they have long, narrow but flattened (ribbon-like) telopodes, with humps generated by the podoms. FIB-SEM tomography also confirms the network made by TCs in the cardiac interstitium through adherens junctions. This study provides the first FIB-SEM tomography of a human cell type. PMID:25327290
Graphical Tools for Linear Structural Equation Modeling
2014-06-01
others. 4Kenny and Milan (2011) write, “Identification is perhaps the most difficult concept for SEM researchers to understand. We have seen SEM...model to using typical SEM software to determine model identifia- bility. Kenny and Milan (2011) list the following drawbacks: (i) If poor starting...the well known recursive and null rules (Bollen, 1989) and the regression rule (Kenny and Milan , 2011). A Simple Criterion for Identifying Individual
The serpentine end-matched joint: evaluating strength and stability
Charles J. Gatchell; Curtis C. Peters
1981-01-01
The Serpentine end-matched (Sem) joint is a precisely machined butt joint with a sine wave shape. The joint is not readily visible to the eye and performs well in panels made of sugar maple, red oak, black walnut, and black cherry. The Sem joint is unaffected by changes in equilibrium moisture content from 6 to 12 to 18 to 6 percent. Panels containing Sem joints have...
Ronald E. Coleman
1977-01-01
SEMTAP (Serpentine End Match TApe Program) is an easy and inexpensive method of programing a numerically controlled router for the manufacture of SEM (Serpentine End Matching) joints. The SEMTAP computer program allows the user to issue commands that will accurately direct a numerically controlled router along any SEM path. The user need not be a computer programer to...
Katsen-Globa, Alisa; Puetz, Norbert; Gepp, Michael M; Neubauer, Julia C; Zimmermann, Heiko
2016-11-01
One of the often reported artefacts during cell preparation to scanning electron microscopy (SEM) is the shrinkage of cellular objects, that mostly occurs at a certain time-dependent stage of cell drying. Various methods of drying for SEM, such as critical point drying, freeze-drying, as well as hexamethyldisilazane (HMDS)-drying, were usually used. The latter becomes popular since it is a low cost and fast method. However, the correlation of drying duration and real shrinkage of objects was not investigated yet. In this paper, cell shrinkage at each stage of preparation for SEM was studied. We introduce a shrinkage coefficient using correlative light microscopy (LM) and SEM of the same human mesenchymal stem cells (hMSCs). The influence of HMDS-drying duration on the cell shrinkage is shown: the longer drying duration, the more shrinkage is observed. Furthermore, it was demonstrated that cell shrinkage is inversely proportional to cultivation time: the longer cultivation time, the more cell spreading area and the less cell shrinkage. Our results can be applicable for an exact SEM quantification of cell size and determination of cell spreading area in engineering of artificial cellular environments using biomaterials. SCANNING 38:625-633, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
Hayakawa, Eri H; Matsuoka, Hiroyuki
2016-10-01
Scanning electron microscopy (SEM) is a powerful tool used to investigate object surfaces and has been widely applied in both material science and biology. With respect to the study of malaria, SEM revealed that erythrocytes infected with Plasmodium falciparum, a human parasite, display 'knob-like' structures on their surface comprising parasitized proteins. However, detailed methodology for SEM studies of malaria parasites is lacking in the literature making such studies challenging. Here, we provide a step-by-step guide to preparing Plasmodium-infected erythrocytes from two mouse strains for SEM analysis with minimal structural deterioration. We tested three species of murine malaria parasites, P. berghei, P. yoelii, and P. chabaudi, as well as non-parasitized human erythrocytes and P. falciparum-infected erythrocytes for comparisons. Our data demonstrated that the surface structures of parasitized erythrocytes between the three species of murine parasites in the two different strains of mice were indistinguishable and no surface alterations were observed in P. falciparum-erythrocytes. Our SEM observations contribute towards an understanding of the molecular mechanisms of parasite maturation in the erythrocyte cytoplasm and, along with future studies using our detailed methodology, may help to gain insight into the clinical phenomena of human malaria. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Furuke, Hirotaka; Komatsu, Shuhei; Ikeda, Jun; Tanaka, Sachie; Kumano, Tatsuya; Imura, Ken-Ichiro; Shimomura, Katsumi; Taniguchi, Fumihiro; Ueshima, Yasuo; Takashina, Ken-Ichiro; Lee, Chol Joo; Deguchi, Eiichi; Ikeda, Eito; Otsuji, Eigo; Shioaki, Yasuhiro
2018-03-01
The self-expandable metallic stent (SEMS) is an excellent non-invasive tool for emergent bowel obstruction. This study was designed to evaluate the clinical usefulness of the SEMS for avoiding perioperative complications. We analyzed a total of 47 consecutive patients who had a bowel obstruction due to colorectal cancer at initial diagnosis between 2012 and 2017 from hospital records. Perioperative complications occurred in 30% (14/47) of patients. Univariate and multivariate logistic regression analyses identified an age of more than 75 years [p=0.037, OR=6.84 (95% CI=1.11-41.6)] and the absence of an SEMS treatment [p=0.028, OR=18.5 (95% CI=1.36-250.0)] as independent risk factors for perioperative complications. Pneumonia (12.7% (6/47)) was the most common complication. There were no pneumonia patients (0% (0/15)) who were treated with the SEMS. In contrast to patients with the non-SEMS treatment, 18.7% (6/32) of all patients and 35.7% (5/14) of elderly patients had pneumonia. The SEMS is a safe and effective treatment for avoiding perioperative complications, particularly pneumonia, and may be a crucial strategy in elderly patients with acute obstruction due to colorectal cancer. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Zanghì, A; Piccolo, G; Cavallaro, A; Pulvirenti, E; Lo Menzo, E; Cardì, F; Di Vita, M; Cappellani, A
2016-12-01
To evaluate the oncologic safety of colonic self-expandable metal stents (SEMS) in obstructive colon cancer. We retrospectively reviewed all the patients who were treated with endoscopic placement of a self-expandable metallic stent (SEMS) at our institution. A total of 26 patients were identified during the study period, of which 24 patients (92.30%) were treated with SEMS as a bridge-to-surgery and 2 (7.69%) as palliation. In 22 cases (80.76%), the stenosis was localized to the left side. Clinical success with resolution of bowel obstructions was achieved in 22 (84.61%) patients within a short period of time. Among patients treated successfully with SEMS insertion as bridge to surgery (n = 22), 20 (90.9%) underwent one-stage surgery with primary anastomosis while 2 patients (9.09%) underwent colostomy due to intraoperative evidence of a covered perforation by cancer tissue in the pelvis. Patients with subclinical perforation developed an early peritoneal carcinomatosis, 10 patients treated with curative intent subsequently developed liver metastasis after 24 months. We reported an overall poor outcome among patients treated with the insertion of SEMS. This led us to think that, in some cases, occlusion may be better than a "silent" perforation.
Safety and Efficacy of a Fully Covered Self-Expandable Metallic Stent in Benign Airway Stenosis.
Fortin, Marc; Lacasse, Yves; Elharrar, Xavier; Tazi-Mezalek, Rachid; Laroumagne, Sophie; Guinde, Julien; Astoul, Philippe; Dutau, Hervé
2017-01-01
The use of self-expandable metallic stents (SEMS) in benign airway disease was the object of a boxed warning from the United States Food and Drug Administration in 2005 due to the risk of stent-related complications and difficulties associated with their removal. Third-generation fully covered SEMS have been commercialized since this warning and theoretically should not present the same difficulties associated with removal as they cannot become embedded in the airway mucosa. We aimed to examine the safety and efficacy of a specific third-generation SEMS, the Silmet stent. We reviewed the records of all patients treated for benign airway stenosis with third-generation Silmet SEMS from January 2011 to December 2015 at the North Hospital of Marseilles, France. Forty SEMS were inserted in 30 patients over this period. Twenty (50.0%) stents were removed because of stent-related complications after a median of 77.0 ± 96.6 days (migration 32.5%, granulation tissue formation 7.5%, subjective intolerance 5.0%, mucus plugging 2.5%, laryngeal edema 2.5%). There were no cases of stent-related mortality. All complications were managed successfully endoscopically. Thirty-six stents (90.0%) were removed successfully after a median of 122.0 ± 113.2 days without any complications. The clinical success rate of stent treatment was 40.7%. Third-generation SEMS are a safe treatment option for complex benign airway stenosis, but complications requiring stent removal are frequent. Further studies are needed to compare the performance of third-generation SEMS and silicone stents in benign airway stenosis. © 2017 S. Karger AG, Basel.
Sub-50 nm metrology on extreme ultra violet chemically amplified resist—A systematic assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maas, D. J., E-mail: diederik.maas@tno.nl; Herfst, R.; Veldhoven, E. van
2015-10-15
With lithographic patterning dimensions decreasing well below 50 nm, it is of high importance to understand metrology at such small scales. This paper presents results obtained from dense arrays of contact holes (CHs) with various Critical Dimension (CD) between 15 and 50 nm, as patterned in a chemically amplified resist using an ASML EUV scanner and measured at ASML and TNO. To determine the differences between various (local) CD metrology techniques, we conducted an experiment using optical scatterometry, CD-Scanning Electron Microscopy (CD-SEM), Helium ion Microscopy (HIM), and Atomic Force Microscopy (AFM). CD-SEM requires advanced beam scan strategies to mitigate samplemore » charging; the other tools did not need that. We discuss the observed main similarities and differences between the various techniques. To this end, we assessed the spatial frequency content in the raw images for SEM, HIM, and AFM. HIM and AFM resolve the highest spatial frequencies, which are attributed to the more localized probe-sample interaction for these techniques. Furthermore, the SEM, HIM, and AFM waveforms are analyzed in detail. All techniques show good mutual correlation, albeit the reported CD values systematically differ significantly. HIM systematically reports a 25% higher CD uniformity number than CD-SEM for the same arrays of CHs, probably because HIM has a higher resolution than the CD-SEM used in this assessment. A significant speed boost for HIM and AFM is required before these techniques are to serve the demanding industrial metrology applications like optical critical dimension and CD-SEM do nowadays.« less
Inoue, Tadahisa; Naitoh, Itaru; Okumura, Fumihiro; Ozeki, Takanori; Anbe, Kaiki; Iwasaki, Hiroyasu; Nishie, Hirotada; Mizushima, Takashi; Sano, Hitoshi; Nakazawa, Takahiro; Yoneda, Masashi; Joh, Takashi
2016-11-01
Endoscopic reintervention for stent occlusions following bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstruction (MHBO) is challenging, and time to recurrent biliary obstruction (RBO) of the revisionary stent remains unclear. We aimed to clarify a suitable reintervention method for stent occlusions following bilateral SEMS placement for MHBO. Between 2002 and 2014, 52 consecutive patients with MHBO who underwent endoscopic reintervention for stent occlusion after bilateral SEMS placement were enrolled at two university hospitals and one tertiary care referral center. We retrospectively evaluated the technical and functional success rates of the reinterventions, and the time to RBO of the revisionary stents. Technical and functional success rates of the reinterventions were 92% (48/52) and 90% (43/48), respectively. Univariate analysis did not determine any significant predictive factors for technical and functional failures. Median time to RBO of the revisionary stents was 68 days. Median time to RBO was significantly longer for revisionary SEMS placement than for plastic stent placement (131 days vs 47 days, respectively; log-rank test, P = 0.005). Revisionary SEMS placement was the only independent factor that was significantly associated with a longer time to RBO of the revisionary stent in the multivariate Cox proportional hazards analysis (hazard ratio 0.37; 95% confidence interval 0.14-0.95; P = 0.039). Revisionary SEMS placement is a suitable endoscopic reintervention method for stent occlusion following bilateral SEMS placement from the perspective of time to RBO of the revisionary stent. © 2016 Japan Gastroenterological Endoscopy Society.
Effect of coffee and tea on the glycaemic index of foods: no effect on mean but reduced variability.
Aldughpassi, Ahmed; Wolever, Thomas M S
2009-05-01
Coffee and tea may influence glycaemic responses but it is not clear whether they affect the glycaemic index (GI) value of foods. Therefore, to see if coffee and tea affected the mean and SEM of GI values, the GI of fruit leather (FL) and cheese puffs (CP) were determined twice in ten subjects using the FAO/WHO protocol with white bread as the reference food. In one series subjects chose to drink 250 ml of either coffee or tea with all test meals, while in the other series they drank 250 ml water. The tests for both series were conducted as a single experiment with the order of all tests being randomised. Coffee and tea increased the overall mean peak blood glucose increment compared with water by 0.25 (SEM 0.09) mmol/l (P=0.02), but did not significantly affect the incremental area under the glucose response curve. Mean GI values were not affected by coffee or tea but the SEM was reduced by about 30% (FL: 31 (SEM 4) v. 35 (SEM 7) and CP: 76 (SEM 6) v. 75 (SEM 8) for coffee or tea v. water, respectively). The error mean square term from the ANOVA of the GI values was significantly smaller for coffee or tea v. water (F(18, 18) = 2.31; P=0.04). We conclude that drinking coffee or tea with test meals does not affect the mean GI value obtained, but may reduce variability and, hence, improve precision.
Petrosyan, Hayk A.; Alessi, Valentina; Hunanyan, Arsen S.; Sisto, Sue A.
2015-01-01
Our recent terminal experiments revealed that administration of a single train of repetitive spinal electromagnetic stimulation (sEMS; 35 min) enhanced synaptic plasticity in spinal circuitry following lateral hemisection spinal cord injury. In the current study, we have examined effects of repetitive sEMS applied as a single train and chronically (5 wk, every other day) following thoracic T10 contusion. Chronic studies involved examination of systematic sEMS administration alone and combined with exercise training and transgene delivery of neurotrophin [adeno-associated virus 10-neurotrophin 3 (AAV10-NT3)]. Electrophysiological intracellular/extracellular recordings, immunohistochemistry, behavioral testing, and anatomical tracing were performed to assess effects of treatments. We found that administration of a single sEMS train induced transient facilitation of transmission through preserved lateral white matter to motoneurons and hindlimb muscles in chronically contused rats with effects lasting for at least 2 h. These physiological changes associated with increased immunoreactivity of GluR1 and GluR2/3 glutamate receptors in lumbar neurons. Systematic administration of sEMS alone for 5 wk, however, was unable to induce cumulative improvements of transmission in spinomuscular circuitry or improve impaired motor function following thoracic contusion. Encouragingly, chronic administration of sEMS, followed by exercise training (running in an exercise ball and swimming), induced the following: 1) sustained strengthening of transmission to lumbar motoneurons and hindlimb muscles, 2) better retrograde transport of anatomical tracer, and 3) improved locomotor function. Greatest improvements were seen in the group that received exercise combined with sEMS and AAV-NT3. PMID:26424579
Petrosyan, Hayk A; Alessi, Valentina; Hunanyan, Arsen S; Sisto, Sue A; Arvanian, Victor L
2015-11-01
Our recent terminal experiments revealed that administration of a single train of repetitive spinal electromagnetic stimulation (sEMS; 35 min) enhanced synaptic plasticity in spinal circuitry following lateral hemisection spinal cord injury. In the current study, we have examined effects of repetitive sEMS applied as a single train and chronically (5 wk, every other day) following thoracic T10 contusion. Chronic studies involved examination of systematic sEMS administration alone and combined with exercise training and transgene delivery of neurotrophin [adeno-associated virus 10-neurotrophin 3 (AAV10-NT3)]. Electrophysiological intracellular/extracellular recordings, immunohistochemistry, behavioral testing, and anatomical tracing were performed to assess effects of treatments. We found that administration of a single sEMS train induced transient facilitation of transmission through preserved lateral white matter to motoneurons and hindlimb muscles in chronically contused rats with effects lasting for at least 2 h. These physiological changes associated with increased immunoreactivity of GluR1 and GluR2/3 glutamate receptors in lumbar neurons. Systematic administration of sEMS alone for 5 wk, however, was unable to induce cumulative improvements of transmission in spinomuscular circuitry or improve impaired motor function following thoracic contusion. Encouragingly, chronic administration of sEMS, followed by exercise training (running in an exercise ball and swimming), induced the following: 1) sustained strengthening of transmission to lumbar motoneurons and hindlimb muscles, 2) better retrograde transport of anatomical tracer, and 3) improved locomotor function. Greatest improvements were seen in the group that received exercise combined with sEMS and AAV-NT3.
Sub-50 nm metrology on extreme ultra violet chemically amplified resist—A systematic assessment
NASA Astrophysics Data System (ADS)
Maas, D. J.; Fliervoet, T.; Herfst, R.; van Veldhoven, E.; Meessen, J.; Vaenkatesan, V.; Sadeghian, H.
2015-10-01
With lithographic patterning dimensions decreasing well below 50 nm, it is of high importance to understand metrology at such small scales. This paper presents results obtained from dense arrays of contact holes (CHs) with various Critical Dimension (CD) between 15 and 50 nm, as patterned in a chemically amplified resist using an ASML EUV scanner and measured at ASML and TNO. To determine the differences between various (local) CD metrology techniques, we conducted an experiment using optical scatterometry, CD-Scanning Electron Microscopy (CD-SEM), Helium ion Microscopy (HIM), and Atomic Force Microscopy (AFM). CD-SEM requires advanced beam scan strategies to mitigate sample charging; the other tools did not need that. We discuss the observed main similarities and differences between the various techniques. To this end, we assessed the spatial frequency content in the raw images for SEM, HIM, and AFM. HIM and AFM resolve the highest spatial frequencies, which are attributed to the more localized probe-sample interaction for these techniques. Furthermore, the SEM, HIM, and AFM waveforms are analyzed in detail. All techniques show good mutual correlation, albeit the reported CD values systematically differ significantly. HIM systematically reports a 25% higher CD uniformity number than CD-SEM for the same arrays of CHs, probably because HIM has a higher resolution than the CD-SEM used in this assessment. A significant speed boost for HIM and AFM is required before these techniques are to serve the demanding industrial metrology applications like optical critical dimension and CD-SEM do nowadays.
Park, Insung; Ochiai, Ryuji; Ogata, Hitomi; Kayaba, Momoko; Hari, Sayaka; Hibi, Masanobu; Katsuragi, Yoshihisa; Satoh, Makoto; Tokuyama, Kumpei
2017-04-01
Chlorogenic acids (CGA) are the most abundant polyphenols in coffee. Continuous consumption of CGA reduces body fat and body weight. Since energy metabolism and sleep are controlled by common regulatory factors, consumption of CGA might modulate sleep. Lack of sleep has been identified as a risk factor for obesity, hypertension and type 2 diabetes. The aim of this study was to determine the effects of ingesting CGA over 5 d on energy metabolism and sleep quality in humans. A total of nine healthy subjects (four male and five female) completed a placebo-controlled, double-blinded, cross-over intervention study. Subjects consumed a test beverage containing 0 or 600 mg of CGA for 5 d. On the fifth night, subjects stayed in a whole-room metabolic chamber to measure energy metabolism; sleep was evaluated using polysomnographic recording. It was found that CGA shortened sleep latency (9 (sem 2) v. 16 (sem 4) min, P<0·05) compared with the control, whereas no effect on sleep architecture, such as slow-wave sleep, rapid eye movement or waking after sleep onset, was observed. Indirect calorimetry revealed that consumption of CGA increased fat oxidation (510 (sem 84) kJ/8 h (122 (sem 20) kcal/8 h) v. 331 (sem 79) kJ/8 h (81 (sem 19) kcal/8 h), P<0·05) but did not affect energy expenditure during sleep. Consumption of CGA enhanced parasympathetic activity assessed from heart-rate variability during sleep (999 (sem 77) v. 919 (sem 54), P<0·05). A period of 5-d CGA consumption significantly increased fat oxidation during sleep, suggesting that beverages containing CGA may be beneficial to reduce body fat and prevent obesity. Consumption of CGA shortened sleep latency and did not adversely affect sleep quality.
Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka
2012-05-01
Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.
Haapamäki, Carola; Kylänpää, Leena; Udd, Marianne; Lindström, Outi; Grönroos, Juha; Saarela, Arto; Mustonen, Harri; Halttunen, Jorma
2015-07-01
The use of covered self-expandable metallic stents (cSEMS) in benign biliary indications is evolving. The aim of the study was to assess the safety and feasibility of cSEMS compared with multiple plastic stents in the treatment of benign biliary stricture (BBS) caused by chronic pancreatitis. This was a prospective, multicenter, randomized study of 60 patients with BBS caused by chronic pancreatitis. All patients received an initial plastic stent before randomization. At randomization, the stent was replaced either with a single cSEMS or three plastic stents. After 3 months, the position of the cSEMS was checked or another three plastic stents were added. At 6 months after randomization, all stents were removed. Clinical follow-up including abdominal ultrasound and laboratory tests were performed at 6 months and 2 years after stent removal. Two patients dropped out of the cSEMS group before stent removal. In April 2014, the median follow-up was 40 months (range 1 - 66 months). The 2-year, stricture-free success rate was 90 % (95 % confidence interval [CI] 72 % - 97 %) in the plastic stent group and 92 % (95 %CI 70 % - 98 %) in the cSEMS group (P = 0.405). There was one late recurrence in the plastic stent group 50 months after stent removal. Stent migration occurred three times (10 %) in the plastic stent group and twice in the cSEMS group (7 %; P = 1.000). A 6-month treatment with either six 10-Fr plastic stents or with one 10-mm cSEMS produced good long-term relief of biliary stricture caused by chronic pancreatitis.Study registered at ClinicalTrials.gov (NCT01085747). © Georg Thieme Verlag KG Stuttgart · New York.
Cosgrove, Natalie; Siddiqui, Ali A; Adler, Douglas G; Shahid, Haroon; Sarkar, Avik; Sharma, Ashish; Kowalski, Thomas E; Loren, David; Warndorf, Matthew; Chennat, Jennifer; Munigala, Satish; Papachristou, Georgios I
2017-07-01
The optimal method for endoscopic placement of bilateral self-expanding metal stents (SEMS) for the management of malignant hilar biliary obstruction has not been determined. The aim of this study was to compare the efficacies and complication rates between SEMS placed above and across the sphincter of Oddi (SO) in patients with malignant hilar biliary obstruction. A retrospective review of patients with malignant hilar strictures who underwent bilateral SEMS placement at 3 centers was performed. Patients were divided into 2 groups: group A (above SO, n=52) or B (across SO, n=120). Patient demographics, technical success (successful SEMS placement across the stricture), functional success (decrease in pretreatment bilirubin level), complications, stent occlusion, and patient survival in the 2 groups were evaluated. We identified 172 patients with malignant hilar biliary obstruction (106 males, mean age 67 y). Significantly more early complications (1.9% vs. 11.7%, P=0.04) were seen in group B, mainly post-endoscopic retrograde cholangio-pancreatography pancreatitis. Mean SEMS patency periods were 33 weeks for group A and 29.6 weeks for group B (P=0.3). Occlusion rates were 50% and 45% for groups A and B (P=0.61); occlusion was due to tumor in-growth or overgrowth in all patients. SEMS occlusion was successfully treated endoscopically in 85% (22/26) patients in group A and 96% (52/54) in group B (P=0.24). The median survival time was 26 weeks in the group A and 29 weeks in group B (P=0.49). Bilateral side-by-side SEMS placement above or below the SO results in similar success rates, stent patency duration, and stent occlusion rates. Significantly fewer complications, with a trend toward lower rates of pancreatitis, were observed for SEMS placed above the SO.
Sparsity-Based Super Resolution for SEM Images.
Tsiper, Shahar; Dicker, Or; Kaizerman, Idan; Zohar, Zeev; Segev, Mordechai; Eldar, Yonina C
2017-09-13
The scanning electron microscope (SEM) is an electron microscope that produces an image of a sample by scanning it with a focused beam of electrons. The electrons interact with the atoms in the sample, which emit secondary electrons that contain information about the surface topography and composition. The sample is scanned by the electron beam point by point, until an image of the surface is formed. Since its invention in 1942, the capabilities of SEMs have become paramount in the discovery and understanding of the nanometer world, and today it is extensively used for both research and in industry. In principle, SEMs can achieve resolution better than one nanometer. However, for many applications, working at subnanometer resolution implies an exceedingly large number of scanning points. For exactly this reason, the SEM diagnostics of microelectronic chips is performed either at high resolution (HR) over a small area or at low resolution (LR) while capturing a larger portion of the chip. Here, we employ sparse coding and dictionary learning to algorithmically enhance low-resolution SEM images of microelectronic chips-up to the level of the HR images acquired by slow SEM scans, while considerably reducing the noise. Our methodology consists of two steps: an offline stage of learning a joint dictionary from a sequence of LR and HR images of the same region in the chip, followed by a fast-online super-resolution step where the resolution of a new LR image is enhanced. We provide several examples with typical chips used in the microelectronics industry, as well as a statistical study on arbitrary images with characteristic structural features. Conceptually, our method works well when the images have similar characteristics, as microelectronics chips do. This work demonstrates that employing sparsity concepts can greatly improve the performance of SEM, thereby considerably increasing the scanning throughput without compromising on analysis quality and resolution.
A wavelet based method for automatic detection of slow eye movements: a pilot study.
Magosso, Elisa; Provini, Federica; Montagna, Pasquale; Ursino, Mauro
2006-11-01
Electro-oculographic (EOG) activity during the wake-sleep transition is characterized by the appearance of slow eye movements (SEM). The present work describes an algorithm for the automatic localisation of SEM events from EOG recordings. The algorithm is based on a wavelet multiresolution analysis of the difference between right and left EOG tracings, and includes three main steps: (i) wavelet decomposition down to 10 detail levels (i.e., 10 scales), using Daubechies order 4 wavelet; (ii) computation of energy in 0.5s time steps at any level of decomposition; (iii) construction of a non-linear discriminant function expressing the relative energy of high-scale details to both high- and low-scale details. The main assumption is that the value of the discriminant function increases above a given threshold during SEM episodes due to energy redistribution toward higher scales. Ten EOG recordings from ten male patients with obstructive sleep apnea syndrome were used. All tracings included a period from pre-sleep wakefulness to stage 2 sleep. Two experts inspected the tracings separately to score SEMs. A reference set of SEM (gold standard) were obtained by joint examination by both experts. Parameters of the discriminant function were assigned on three tracings (design set) to minimize the disagreement between the system classification and classification by the two experts; the algorithm was then tested on the remaining seven tracings (test set). Results show that the agreement between the algorithm and the gold standard was 80.44+/-4.09%, the sensitivity of the algorithm was 67.2+/-7.37% and the selectivity 83.93+/-8.65%. However, most errors were not caused by an inability of the system to detect intervals with SEM activity against NON-SEM intervals, but were due to a different localisation of the beginning and end of some SEM episodes. The proposed method may be a valuable tool for computerized EOG analysis.
Quantitative approach for optimizing e-beam condition of photoresist inspection and measurement
NASA Astrophysics Data System (ADS)
Lin, Chia-Jen; Teng, Chia-Hao; Cheng, Po-Chung; Sato, Yoshishige; Huang, Shang-Chieh; Chen, Chu-En; Maruyama, Kotaro; Yamazaki, Yuichiro
2018-03-01
Severe process margin in advanced technology node of semiconductor device is controlled by e-beam metrology system and e-beam inspection system with scanning electron microscopy (SEM) image. By using SEM, larger area image with higher image quality is required to collect massive amount of data for metrology and to detect defect in a large area for inspection. Although photoresist is the one of the critical process in semiconductor device manufacturing, observing photoresist pattern by SEM image is crucial and troublesome especially in the case of large image. The charging effect by e-beam irradiation on photoresist pattern causes deterioration of image quality, and it affect CD variation on metrology system and causes difficulties to continue defect inspection in a long time for a large area. In this study, we established a quantitative approach for optimizing e-beam condition with "Die to Database" algorithm of NGR3500 on photoresist pattern to minimize charging effect. And we enhanced the performance of measurement and inspection on photoresist pattern by using optimized e-beam condition. NGR3500 is the geometry verification system based on "Die to Database" algorithm which compares SEM image with design data [1]. By comparing SEM image and design data, key performance indicator (KPI) of SEM image such as "Sharpness", "S/N", "Gray level variation in FOV", "Image shift" can be retrieved. These KPIs were analyzed with different e-beam conditions which consist of "Landing Energy", "Probe Current", "Scanning Speed" and "Scanning Method", and the best e-beam condition could be achieved with maximum image quality, maximum scanning speed and minimum image shift. On this quantitative approach of optimizing e-beam condition, we could observe dependency of SEM condition on photoresist charging. By using optimized e-beam condition, measurement could be continued on photoresist pattern over 24 hours stably. KPIs of SEM image proved image quality during measurement and inspection was stabled enough.
Wang, Fang; Ouyang, Guang; Zhou, Changsong; Wang, Suiping
2015-01-01
A number of studies have explored the time course of Chinese semantic and syntactic processing. However, whether syntactic processing occurs earlier than semantics during Chinese sentence reading is still under debate. To further explore this issue, an event-related potentials (ERPs) experiment was conducted on 21 native Chinese speakers who read individually-presented Chinese simple sentences (NP1+VP+NP2) word-by-word for comprehension and made semantic plausibility judgments. The transitivity of the verbs was manipulated to form three types of stimuli: congruent sentences (CON), sentences with a semantically violated NP2 following a transitive verb (semantic violation, SEM), and sentences with a semantically violated NP2 following an intransitive verb (combined semantic and syntactic violation, SEM+SYN). The ERPs evoked from the target NP2 were analyzed by using the Residue Iteration Decomposition (RIDE) method to reconstruct the ERP waveform blurred by trial-to-trial variability, as well as by using the conventional ERP method based on stimulus-locked averaging. The conventional ERP analysis showed that, compared with the critical words in CON, those in SEM and SEM+SYN elicited an N400-P600 biphasic pattern. The N400 effects in both violation conditions were of similar size and distribution, but the P600 in SEM+SYN was bigger than that in SEM. Compared with the conventional ERP analysis, RIDE analysis revealed a larger N400 effect and an earlier P600 effect (in the time window of 500-800 ms instead of 570-810ms). Overall, the combination of conventional ERP analysis and the RIDE method for compensating for trial-to-trial variability confirmed the non-significant difference between SEM and SEM+SYN in the earlier N400 time window. Converging with previous findings on other Chinese structures, the current study provides further precise evidence that syntactic processing in Chinese does not occur earlier than semantic processing.
Rymer, C; Hartnell, G F; Givens, D I
2011-03-01
Supplementing broiler diets with conventional vegetable oils has little effect on the long-chain n-3 PUFA (LC n-3 PUFA) content of the meat. The present study investigated the effect on fatty acid composition and sensory characteristics of chicken meat when broilers were fed oil extracted from soyabeans (SDASOY) that had been genetically engineered to produce C18 : 4n-3 (stearidonic acid (SDA), 240 mg/g oil). Three diets were fed to 120 birds (eight replicate pens of five birds) from 15 d to slaughter (41-50 d). Diets were identical apart from the oil added to them (45 and 50 g/kg as fed in the grower and finisher phases, respectively), which was either SDASOY, near-isogenic soya (CON) or fish oil (FISH). The LC n-3 PUFA content of the meat increased in the order CON, SDASOY and FISH. In breast meat with skin, the SDA concentration was 522, 13 and 37 (sem 14·4) mg/100 g meat for SDASOY, CON and FISH, respectively. Equivalent values for C20 : 5n-3 (EPA) were 53, 13 and 140 (sem 8·4); for C22 : 5n-3 (docosapentaenoic acid (DPA)) 65, 15 and 101 (sem 3·5); for C22 : 6n-3 (DHA) 19, 9 and 181 (sem 4·4). Leg meat (with skin) values for SDA were 861, 23 and 68 (sem 30·1); for EPA 87, 9 and 258 (sem 7·5); for DPA 95, 20 and 165 (sem 5·0); for DHA 29, 10 and 278 (sem 8·4). Aroma, taste and aftertaste of freshly cooked breast meat were not affected. Fishy aromas, tastes and aftertastes were associated with LC n-3 PUFA content of the meat, being most noticeable in the FISH leg meat (both freshly cooked and reheated) and in the reheated SDASOY leg meat.
2012-01-01
Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS) and plastic stents (PS).We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS), functional success (FS), early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III). Results The initial stent insertion was successful in 450 (93.8%) patients. TS was achieved in 204 (88.3%) patients treated with PS and in 246 (98.8%) patients palliated with SEMS (p < 0.001). In the intention-to-treat (ITT) analysis, the FS in patients treated with SEMS (97.9%) was significantly higher than in patients treated with PS (84.8%) (p < 0.001). Late complications occurred in 115 (56.4%) patients treated with PS and 60 (24.4%) patients treated with SEMS (p < 0.001). The median duration of stent patency in weeks (w) were as follows: 20 w in patients palliated with PS and 27 w in patients treated with SEMS (p < 0.0001). In Group 2, the median duration of PS patency was 17 w and 18 w for unilateral and bilateral placement, respectively (p = 0.0004); the median duration of SEMS patency was 24 w and 29 w for unilateral and bilateral placement, respectively (p < 0.0001). Multivariate analysis using the Poisson regression showed that SEMS placement (B = 0.48; P < 0.01) and bilateral deployment (B = 0.24; P < 0.01) were the only independent prognostic factors associated with stent patency. Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients. PMID:22873816
Ozaki, H; Nagai, Y; Tochihara, Y
2001-04-01
We evaluated human physiological responses and the performance of manual tasks during exposure to severe cold (-25 degrees C) at night (0300-0500 hours) and in the afternoon (1500-1700 hours). Thirteen male students wearing standard cold protective clothing occupied a severely cold room (-25 degrees C) for 20 min, and were then transferred to a cool room (10 degrees C) for 20 min. This pattern of exposure was repeated three times, for a total time of exposure to extreme cold of 60 min. The experiments were started either at 1500 hours or 0300 hours and measurements of rectal temperature, skin temperature, blood pressure, performance in a counting task, hand tremor, and subjective responses were made in each condition. At the end of the experiment at night the mean decrease in rectal temperature [0.68 (SEM 0.04) degree C] was significantly greater than that at the end of the experiment in the afternoon [0.55 (SEM 0.08) degree C, P < 0.01]. After the second cold exposure at night the mean increase in diastolic blood pressure [90 (SEM 2.0) mmHg] was significantly greater than that at the end of the second cold exposure in the afternoon [82 (SEM 2.8) mmHg, P < 0.01]. At the end of the second cold exposure at night, mean finger skin temperature [11.8 (SEM 0.8) degrees C] was significantly higher than that at the comparable time in the afternoon [9.0 (SEM 0.7) degrees C, P < 0.01]. Similarly for the toe, mean skin temperature at the start of the second cold exposure at night [25.6 (SEM 1.5) degrees C] was significantly higher than in the afternoon [20.1 (SEM 0.8) degrees C, P < 0.01]. The increased skin temperatures in the periphery resulted in increased heat loss. Since peripheral skin temperatures were highest at night, the subjects noted diminished sensations of thermal cold and pain at that time. Manual dexterity at the end of the first cold exposure at night [mean 83.7 (SEM 3.6) times.min-1] had decreased significantly more than at the end of the first cold exposure in the afternoon [mean 89.4 (SEM 3.5) times.min-1, P < 0.01]. These findings of a lowered rectal temperature and diminished manual dexterity suggest that there is an increased risk of both hypothermia and accidents for those who work at night.
Lee, J.-S.; Lee, B.-G.; Luoma, S.N.; Choi, H.J.; Koh, C.-H.; Brown, C.L.
2000-01-01
The influence of acid volatile sulfide (AVS) on the partitioning of Cd, Ni, and Zn in porewater (PW) and sediment as reactive metals (SEM, simultaneously extracted metals) was investigated in laboratory microcosms. Two spiking procedures were compared, and the effects of vertical geochemical gradients and infaunal activity were evaluated. Sediments were spiked with a Cd-Ni-Zn mixture (0.06, 3, 7.5 ??mol/g, respectively) containing four levels of AVS (0.5, 7.5, 15, 35 ??mol/g). The results were compared to sediments spiked with four levels of Cd-Ni-Zn mixtures at one AVS concentration (7.5 ??mol/g). A vertical redox gradient was generated in each treatment by an 18-d incubation with an oxidized water column. [AVS] in the surface sediments decreased by 65-95% due to oxidation during incubation; initial [AVS] was maintained at 0.5-7.5 cm depth. PW metal concentrations were correlated with [SEM - AVS] among all data. But PW metal concentrations were variable, causing the distribution coefficient, Kd(pw) (the ratio of [SEM] to PW metal concentrations) to vary by 2-3 orders of magnitude at a given [SEM - AVS]. One reason for the variability was that vertical profiles in PW metal concentrations appeared to be influenced by diffusion as well as [SEM - AVS]. The presence of animals appeared to enhance the diffusion of at least Zn. The generalization that PW metal concentrations are controlled by [SEM - AVS] is subject to some important qualifications if vertical gradients are complicated, metal concentrations vary, or equilibration times differ.The influence of acid volatile sulfide (AVS) on the partitioning of Cd, Ni, and Zn in porewater (PW) and sediment as reactive metals (SEM, simultaneously extracted metals) was investigated in laboratory microcosms. Two spiking procedures were compared, and the effects of vertical geochemical gradients and infaunal activity were evaluated. Sediments were spiked with a Cd-Ni-Zn mixture (0.06, 3, 7.5 ??mol/g, respectively) containing four levels of AVS (0.5, 7.5, 15, 35 ??mol/g). The results were compared to sediments spiked with four levels of Cd-Ni-Zn mixtures at one AVS concentration (7.5 ??mol/g). A vertical redox gradient was generated in each treatment by an 18-d incubation with an oxidized water column. [AVS] in the surface sediments decreased by 65-95% due to oxidation during incubation; initial [AVS] was maintained at 0.5-7.5 cm depth. PW metal concentrations were correlated with [SEM - AVS] among all data. But PW metal concentrations were variable, causing the distribution coefficient, Kdpw (the ratio of [SEM] to PW metal concentrations) to vary by 2-3 orders of magnitude at a given [SEM - AVS]. One reason for the variability was that vertical profiles in PW metal concentrations appeared to be influenced by diffusion as well as [SEM - AVS]. The presence of animals appeared to enhance the diffusion of at least Zn. The generalization that PW metal concentrations are controlled by [SEM - AVS] is subject to some important qualifications if vertical gradients are complicated, metal concentrations vary, or equilibration times differ.
Processing Research on Chemically Vapor Deposited Silicon Nitride.
1979-12-01
34 sea urchins ") predominated, suggesting that formation was primarily from the vapor phase with little of the nodular growths seen at only slightly...Specimen HW-4-200-10 .................................. 3-38 3-17 Fracture Stress: Grain Size Correlation 3-39 3-18 SEM Fractographs of Flexure...4-202-10 ........ 3-42 3-21 SEM Fractographs of Flexure Specimen HW-4-200-4 ......... 3-43 3-22 SEM Fractographs of Compression Side of Flexure
Preparation and Characterization of Carbon Filaments
1991-04-01
Kawasumi, "Whiskerization of Carbon Beads by Vapor Phase Growth of Carbon Fibers to Obtain Sea Urchin -Type Particles", Carbon 21, 89 (1983). 5) R.T.K...multiple fiber microstructure are possible on what appears to be a single fiber along the length of the fiber. However, without SEM micrographs, it is...180 minutes. Scanning Electron Microscopic ( SEM ) observations were cared out using P Philips series 505 SEM system, typically operating at an
Test and Evaluation of TRUST: Tools for Recognizing Useful Signals of Trustworthiness
2016-04-01
guaranteed, social exchange requires trust—the belief that others will follow through on their obligations. The model includes the beliefs that...current reflection could be measured based on properties of the skin, and (2) skin conductance response (SCR), where the fastest could be measured and...SEM prediction (H4d). The results of the LF HRV signals indicate the SEM model predicts distrust base on the experimental SS paradigm and SEM
[The journal of the Spanish Society of Microbiology, 1945-1995].
Isamat, D; Navarrete, A; Fernández de Castillo, A
1996-03-01
The official journal of the Spanish Society for Microbiology (SEM) was first published in 1947, under the name Microbiología Española. Until 1984 the journal was published by the SEM jointly with the Institute
NASA Astrophysics Data System (ADS)
Wasilah, S.; Fahmyddin, T.
2018-03-01
The employment of structural equation modeling (SEM) in research has taken an increasing attention in among researchers in built environment. There is a gap to understand the attributes, application, and importance of this approach in data analysis in built environment study. This paper intends to provide fundamental comprehension of SEM method in data analysis, unveiling attributes, employment and significance and bestow cases to assess associations amongst variables and constructs. The study uses some main literature to grasp the essence of SEM regarding with built environment research. The better acknowledgment of this analytical tool may assist the researcher in the built environment to analyze data under complex research questions and to test multivariate models in a single study.
SemVisM: semantic visualizer for medical image
NASA Astrophysics Data System (ADS)
Landaeta, Luis; La Cruz, Alexandra; Baranya, Alexander; Vidal, María.-Esther
2015-01-01
SemVisM is a toolbox that combines medical informatics and computer graphics tools for reducing the semantic gap between low-level features and high-level semantic concepts/terms in the images. This paper presents a novel strategy for visualizing medical data annotated semantically, combining rendering techniques, and segmentation algorithms. SemVisM comprises two main components: i) AMORE (A Modest vOlume REgister) to handle input data (RAW, DAT or DICOM) and to initially annotate the images using terms defined on medical ontologies (e.g., MesH, FMA or RadLex), and ii) VOLPROB (VOlume PRObability Builder) for generating the annotated volumetric data containing the classified voxels that belong to a particular tissue. SemVisM is built on top of the semantic visualizer ANISE.1
Precise and economic FIB/SEM for CLEM: with 2 nm voxels through mitosis.
Luckner, Manja; Wanner, Gerhard
2018-05-23
A portfolio is presented documenting economic, high-resolution correlative focused ion beam scanning electron microscopy (FIB/SEM) in routine, comprising: (i) the use of custom-labeled slides and coverslips, (ii) embedding of cells in thin, or ultra-thin resin layers for correlative light and electron microscopy (CLEM) and (iii) the claim to reach the highest resolution possible with FIB/SEM in xyz. Regions of interest (ROIs) defined in light microscope (LM), can be relocated quickly and precisely in SEM. As proof of principle, HeLa cells were investigated in 3D context at all stages of the cell cycle, documenting ultrastructural changes during mitosis: nuclear envelope breakdown and reassembly, Golgi degradation and reconstitution and the formation of the midzone and midbody.
Grainger, Elizabeth M; Hadley, Craig W; Moran, Nancy E; Riedl, Kenneth M; Gong, Michael C; Pohar, Kamal; Schwartz, Steven J; Clinton, Steven K
2015-08-28
Tomato product consumption and estimated lycopene intake are hypothesised to reduce the risk of prostate cancer. To define the impact of typical servings of commercially available tomato products on resultant plasma and prostate lycopene concentrations, men scheduled to undergo prostatectomy (n 33) were randomised either to a lycopene-restricted control group ( < 5 mg lycopene/d) or to a tomato soup (2-2¾ cups prepared/d), tomato sauce (142-198 g/d or 5-7 ounces/d) or vegetable juice (325-488 ml/d or 11-16·5 fluid ounces/d) intervention providing 25-35 mg lycopene/d. Plasma and prostate carotenoid concentrations were measured by HPLC. Tomato soup, sauce and juice consumption significantly increased plasma lycopene concentration from 0·68 (sem 0·1) to 1·13 (sem 0·09) μmol/l (66 %), 0·48 (sem 0·09) to 0·82 (sem 0·12) μmol/l (71 %) and 0·49 (sem 0·12) to 0·78 (sem 0·1) μmol/l (59 %), respectively, while the controls consuming the lycopene-restricted diet showed a decline in plasma lycopene concentration from 0·55 (sem 0·60) to 0·42 (sem 0·07) μmol/l ( - 24 %). The end-of-study prostate lycopene concentration was 0·16 (sem 0·02) nmol/g in the controls, but was 3·5-, 3·6- and 2·2-fold higher in tomato soup (P= 0·001), sauce (P= 0·001) and juice (P= 0·165) consumers, respectively. Prostate lycopene concentration was moderately correlated with post-intervention plasma lycopene concentrations (r 0·60, P =0·001), indicating that additional factors have an impact on tissue concentrations. While the primary geometric lycopene isomer in tomato products was all-trans (80-90 %), plasma and prostate isomers were 47 and 80 % cis, respectively, demonstrating a shift towards cis accumulation. Consumption of typical servings of processed tomato products results in differing plasma and prostate lycopene concentrations. Factors including meal composition and genetics deserve further evaluation to determine their impacts on lycopene absorption and biodistribution.
FIB-SEM tomography in biology.
Kizilyaprak, Caroline; Bittermann, Anne Greet; Daraspe, Jean; Humbel, Bruno M
2014-01-01
Three-dimensional information is much easier to understand than a set of two-dimensional images. Therefore a layman is thrilled by the pseudo-3D image taken in a scanning electron microscope (SEM) while, when seeing a transmission electron micrograph, his imagination is challenged. First approaches to gain insight in the third dimension were to make serial microtome sections of a region of interest (ROI) and then building a model of the object. Serial microtome sectioning is a tedious and skill-demanding work and therefore seldom done. In the last two decades with the increase of computer power, sophisticated display options, and the development of new instruments, an SEM with a built-in microtome as well as a focused ion beam scanning electron microscope (FIB-SEM), serial sectioning, and 3D analysis has become far easier and faster.Due to the relief like topology of the microtome trimmed block face of resin-embedded tissue, the ROI can be searched in the secondary electron mode, and at the selected spot, the ROI is prepared with the ion beam for 3D analysis. For FIB-SEM tomography, a thin slice is removed with the ion beam and the newly exposed face is imaged with the electron beam, usually by recording the backscattered electrons. The process, also called "slice and view," is repeated until the desired volume is imaged.As FIB-SEM allows 3D imaging of biological fine structure at high resolution of only small volumes, it is crucial to perform slice and view at carefully selected spots. Finding the region of interest is therefore a prerequisite for meaningful imaging. Thin layer plastification of biofilms offers direct access to the original sample surface and allows the selection of an ROI for site-specific FIB-SEM tomography just by its pronounced topographic features.
Torres, Lilith; Ortiz, Tatiana; Tang, Qiyi
2015-01-01
Human herpesviruses cause different infectious diseases, resulting in world-wide health problems. Sexual transmission is a major route for the spread of both herpes simplex virus-1 (HSV-1) and -2. Semen plays an important role in carrying the viral particle that invades the vaginal or rectal mucosa and, thereby, initiates viral replication. Previously, we demonstrated that the amyloid fibrils semenogelin (SEM) and semen-derived enhancer of viral infection (SEVI), and seminal plasma (SP) augment cytomegalovirus infection (Tang et al., J. Virol 2013). Whether SEM or SEVI amyloids or SP could also enhance other herpesvirus infections has not been examined. In this study, we found that the two amyloids as well as SP strongly enhance both HSV-1 and -2 infections in cell culture. Along with SP, SEM and SEVI amyloids enhanced viral entry and increased infection rates by more than 10-fold, as assessed by flow cytometry assay and fluorescence microscopy. Viral replication was increased by about 50- to 100-fold. Moreover, viral growth curve assays showed that SEM and SEVI amyloids, as well as SP, sped up the kinetics of HSV replication such that the virus reached its replicative peak more quickly. The interactions of SEM, SEVI, and SP with HSVs are direct. Furthermore, we discovered that the enhancing effects of SP, SEM, and SEVI can be significantly reduced by heparin, a sulfated polysaccharide with an anionic charge. It is probable that heparin abrogates said enhancing effects by interfering with the interaction of the viral particle and the amyloids, which interaction results in the binding of the viral particles and both SEM and SEVI. PMID:25903833
Beaumelle, Léa; Vile, Denis; Lamy, Isabelle; Vandenbulcke, Franck; Gimbert, Frédéric; Hedde, Mickaël
2016-11-01
Structural equation models (SEM) are increasingly used in ecology as multivariate analysis that can represent theoretical variables and address complex sets of hypotheses. Here we demonstrate the interest of SEM in ecotoxicology, more precisely to test the three-step concept of metal bioavailability to earthworms. The SEM modeled the three-step causal chain between environmental availability, environmental bioavailability and toxicological bioavailability. In the model, each step is an unmeasured (latent) variable reflected by several observed variables. In an exposure experiment designed specifically to test this SEM for Cd, Pb and Zn, Aporrectodea caliginosa was exposed to 31 agricultural field-contaminated soils. Chemical and biological measurements used included CaC12-extractable metal concentrations in soils, free ion concentration in soil solution as predicted by a geochemical model, dissolved metal concentration as predicted by a semi-mechanistic model, internal metal concentrations in total earthworms and in subcellular fractions, and several biomarkers. The observations verified the causal definition of Cd and Pb bioavailability in the SEM, but not for Zn. Several indicators consistently reflected the hypothetical causal definition and could thus be pertinent measurements of Cd and Pb bioavailability to earthworm in field-contaminated soils. SEM highlights that the metals present in the soil solution and easily extractable are not the main source of available metals for earthworms. This study further highlights SEM as a powerful tool that can handle natural ecosystem complexity, thus participating to the paradigm change in ecotoxicology from a bottom-up to a top-down approach. Copyright © 2016 Elsevier B.V. All rights reserved.
Park, Se Woo; Lee, Hyuk; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan
2014-03-01
Conventional endoscopy for self-expandable metallic stent (SEMS) placement may be technically limited in long and tortuous strictures. Therefore, we analyzed the feasibility, safety and usefulness of ultrathin endoscopy (UTE)-guided SEMS placement. This study involved 24 patients with upper gastrointestinal obstruction and unsuccessful initial attempts to place SEMS using conventional endoscopy. After completely passing a UTE across the stricture, the UTE was withdrawn, leaving a guidewire placed via the working channel. Through-the-scope SEMS placement was done using a conventional endoscope inserted along the guidewire. The primary endpoints were assessed by technical/clinical success and stent patency duration. Stents were successfully placed at target locations in all but one case with a long tortuous stricture, with 95.8% (23/24) technical success. One week after stent placement, mean gastricoutlet obstruction score improved significantly from baseline (1.74 ± 0.62 and 0.33 ± 0.48, respectively; P < 0.001). Stent migration, restenosis, and fracture occurred in four (17.4%), six (26.1%), and one (4.3%) of 23 stents, respectively. Median stent patency duration was 79 days. Mean stent patency was significantly longer in patients who received palliative chemotherapy than in those who did not (122.9 ± 11.0 and 38.3 ± 4.6, respectively; P < 0.001). UTE guidance SEMS delivery can be a feasible and safe rescue treatment method for malignant upper gastrointestinal obstruction in cases of failed attempts to place SEMS using conventional endoscopy. Our result warrants a further study to define the efficacy of this method in difficult SEMS placement cases. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Kassam, H; Tzortziou Brown, V; O'Halloran, P; Wheeler, P; Fairclough, J; Maffulli, N; Morrissey, D
2014-12-01
Sport and exercise medicine (SEM) aims to manage sporting injuries and promote physical activity. This study explores general practitioners' (GPs) awareness, understanding and utilisation of their local SEM services. A questionnaire survey, including patient case scenarios, was administered between February and May 2011. 693 GPs working in Cardiff and Vale, Leicester and Tower Hamlets were invited to participate. 244 GPs responded to the questionnaire (35.2% response rate). Less than half (46%; 112/244) were aware of their nearest SEM service and only 38% (92/244) had a clear understanding on referral indications. The majority (82%; 199/244) felt confident advising less active patients about exercise. There were divergent management opinions about the case scenarios of patients who were SEM referral candidates. Overall, GPs were significantly more likely to refer younger patients and patients with sport-related problems rather than patients who would benefit from increasing their activity levels in order to prevent or manage chronic conditions (p<0.01). GPs with previous SEM training were significantly more likely to refer (p<0.01). The majority (62%; 151/244) had never referred patients to their local SEM clinics but of those who had 75% (70/93) rated the service as good. There is a lack of awareness and understanding among GPs on the role of SEM within the National Health Service which may be resulting in suboptimal utilisation especially for patients who could benefit from increasing their activity levels. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Didden, Paul; Reijm, Agnes N; Erler, Nicole S; Wolters, Leonieke M M; Tang, Thjon J; Ter Borg, Pieter C J; Leeuwenburgh, Ivonne; Bruno, Marco J; Spaander, Manon C W
2018-06-12
Covered esophageal self-expandable metal stents (SEMSs) are currently used for palliation of malignant dysphagia. The optimal extent of the covering to prevent recurrent obstruction is unknown. Therefore, we aimed to compare fully covered (FC) versus partially covered (PC) SEMSs in patients with incurable malignant esophageal stenosis. In this multicenter randomized controlled trial, 98 incurable patients with dysphagia caused by a malignant stricture of the esophagus or cardia were randomized 1:1 to an FC-SEMS or PC-SEMS. The primary outcome was recurrent obstruction after endoscopic SEMS placement. Secondary outcomes were technical and clinical success, adverse events, and health-related quality of life (HRQoL). Patients were followed until 6 months after SEMS placement or to SEMS removal, second SEMS insertion, or death, whichever came first. Recurrent obstruction after SEMS placement was similar for both types of stents: 19 % for FC-SEMSs and 22 % for PC-SEMSs ( P = 0.65). The times to recurrent obstruction did not differ. The frequency of adverse events was similar between the two groups, with major adverse events occurring in 38 % and 47 % of patients for FC-SEMSs and PC-SEMSs, respectively ( P = 0.34). No significant differences were seen in technical success, improvement of dysphagia, and HRQoL. Proximal esophageal stenosis and female sex were independently associated with recurrent obstruction and/or major adverse events. Esophageal FC-SEMSs did not reveal a lower recurrent obstruction rate compared with PC-SEMSs in the palliative management of malignant dysphagia. © Georg Thieme Verlag KG Stuttgart · New York.
Soya isoflavone-enriched cereal bars affect markers of endothelial function in postmenopausal women.
Hallund, J; Bügel, S; Tholstrup, T; Ferrari, M; Talbot, D; Hall, W L; Reimann, M; Williams, C M; Wiinberg, N
2006-06-01
Soya isoflavones are thought to be cardioprotective due to their structural similarity to oestrogen. In order to investigate the effect of soya isoflavones on markers of endothelial function we conducted a randomised, double-blind, placebo-controlled, cross-over study with thirty healthy postmenopausal women. The women consumed cereal bars, with or without soya isoflavones (50 mg/d), for 8 weeks, separated by an 8-week washout period. Systemic arterial compliance (SAC), isobaric arterial compliance (IAC), flow-mediated endothelium-dependent vasodilation (FMD) and nitroglycerine-mediated endothelium-independent vasodilation (NMD) were measured at the beginning of the study and after each intervention period. Blood pressure (BP) and plasma concentrations of nitrite and nitrate (NOx) and endothelin-1 (ET-1) were measured at the beginning and end of each intervention period. NMD was 13.4 (SEM 2.0)% at baseline and 15.5 (SEM 1.1) % after isoflavone treatment compared with 12.4 (SEM 1.0)% after placebo treatment (P=0.03). NOx increased from 27.7 (SEM 2.7) to 31.1 (SEM 3.2) microM after isoflavones treatment compared with 25.4 (SEM 1.5) to 20.4 (SEM 1.1) microM after placebo treatment (P=0.003) and a significant increase in the NOx:ET-1 ratio (P=0.005) was observed after the isoflavone treatment compared with placebo. A significant difference in SAC after the isoflavone and placebo treatment was observed (P=0.04). No significant difference was found in FMD, IAC, BP and ET-1. In conclusion, 8 weeks' consumption of cereals bars enriched with 50 mg soya isoflavones/d increased plasma NOx concentrations and improved endothelium-independent vasodilation in healthy postmenopausal women.
Scanning electron microscopy of clays and clay minerals
Bohor, B.F.; Hughes, R.E.
1971-01-01
The scanning electron microscope (SEM) proves to be ideally suited for studying the configuration, texture, and fabric of clay samples. Growth mechanics of crystalline units—interpenetration and interlocking of crystallites, crystal habits, twinning, helical growth, and topotaxis—also are uniquely revealed by the SEM.Authigenic kaolins make up the bulk of the examples because their larger crystallite size, better crystallinity, and open texture make them more suited to examination by the SEM than most other clay mineral types.
SEM/EDS and optical microscopy analyses of microplastics in ocean trawl and fish guts.
Wang, Zhong-Min; Wagner, Jeff; Ghosal, Sutapa; Bedi, Gagandeep; Wall, Stephen
2017-12-15
Microplastic particles from Atlantic and Pacific Ocean trawls, lab-fed fish guts and ocean fish guts have been characterized using optical microscopy and SEM/EDS in terms of size, morphology, and chemistry. We assessed whether these measurements could serve as a rapid screening process for subsequent identification of the likely microplastic candidates by micro-spectroscopy. Optical microscopy enabled morphological classification of the types of particles or fibers present in the sample, as well as the quantification of particle size ranges and fiber lengths. SEM/EDS analysis was used to rule out non-plastic particles and screen the prepared samples for potential microplastic, based on their element signatures and surface characteristics. Chlorinated plastics such as polyvinyl chloride (PVC) could be easily identified with SEM/EDS due to their unique elemental signatures including chlorine, as could mineral species that are falsely identified as plastics by optical microscopy. Particle morphology determined by optical microscopy and SEM suggests the fish ingested particles contained both degradation fragments from larger plastic pieces and also manufactured microplastics. SEM images of microplastic particle surfaces revealed characteristic cracks consistent with environmental exposure, as well as pigment particles consistent with manufactured materials. Most of the microplastic surfaces in the fish guts and ocean trawls were covered with biofilms, radiolarians, and crustaceans. Many of the fish stomachs contained micro-shell pieces which visually resembled microplastics. Copyright © 2017 Elsevier B.V. All rights reserved.
Dos Santos, Q M; Avenant-Oldewage, A
2015-02-01
Classification of most monogeneans is primarily based on size, shape, and arrangement of haptoral sclerites. These structures are often obscured or misinterpreted when studied using light microscopy, leading to confusion regarding defining characters. Scanning electron microscopy (SEM) has predominantly been used to study haptoral sclerites in smaller monogeneans, focusing on hooks and anchors. In the Diplozoidae, SEM has not been used to study haptoral sclerites. Using new and modified techniques, the sclerites of diplozoids collected in South Africa were successfully studied using SEM. The digestion buffer from a DNA extraction kit was used to digest the surrounding tissue, and Poly-L-lysine-coated and concavity slides were employed to limit the movement and loss of sclerites, with the latter being more user-friendly. In addition to the success of visualizing the sclerites using SEM, the digested tissue from as little as half of the haptor provided viable genetic material for molecular characterization. From the results presented here, the study of the sclerites of larger monogeneans using SEM, including those bearing clamps, is a viable possibility for future research. Also, this method may be beneficial for the study of other, non-haptoral sclerites, such as cirri in other families of monogeneans. During this study, Labeo capensis was noted as a valid host of Paradiplozoon vaalense in a region of the Vaal River where the type host, Labeo umbratus, appears to be absent.
Minimal resin embedding of multicellular specimens for targeted FIB-SEM imaging.
Schieber, Nicole L; Machado, Pedro; Markert, Sebastian M; Stigloher, Christian; Schwab, Yannick; Steyer, Anna M
2017-01-01
Correlative light and electron microscopy (CLEM) is a powerful tool to perform ultrastructural analysis of targeted tissues or cells. The large field of view of the light microscope (LM) enables quick and efficient surveys of the whole specimen. It is also compatible with live imaging, giving access to functional assays. CLEM protocols take advantage of the features to efficiently retrace the position of targeted sites when switching from one modality to the other. They more often rely on anatomical cues that are visible both by light and electron microscopy. We present here a simple workflow where multicellular specimens are embedded in minimal amounts of resin, exposing their surface topology that can be imaged by scanning electron microscopy (SEM). LM and SEM both benefit from a large field of view that can cover whole model organisms. As a result, targeting specific anatomic locations by focused ion beam-SEM (FIB-SEM) tomography becomes straightforward. We illustrate this application on three different model organisms, used in our laboratory: the zebrafish embryo Danio rerio, the marine worm Platynereis dumerilii, and the dauer larva of the nematode Caenorhabditis elegans. Here we focus on the experimental steps to reduce the amount of resin covering the samples and to image the specimens inside an FIB-SEM. We expect this approach to have widespread applications for volume electron microscopy on multiple model organisms. Copyright © 2017 Elsevier Inc. All rights reserved.
Ellis, Richard; Hing, Wayne; Dilley, Andrew; McNair, Peter
2008-08-01
Diagnostic ultrasound provides a technique whereby real-time, in vivo analysis of peripheral nerve movement is possible. This study measured sciatic nerve movement during a "slider" neural mobilisation technique (ankle dorsiflexion/plantar flexion and cervical extension/flexion). Transverse and longitudinal movement was assessed from still ultrasound images and video sequences by using frame-by-frame cross-correlation software. Sciatic nerve movement was recorded in the transverse and longitudinal planes. For transverse movement, at the posterior midthigh (PMT) the mean value of lateral sciatic nerve movement was 3.54 mm (standard error of measurement [SEM] +/- 1.18 mm) compared with anterior-posterior/vertical (AP) movement of 1.61 mm (SEM +/- 0.78 mm). At the popliteal crease (PC) scanning location, lateral movement was 6.62 mm (SEM +/- 1.10 mm) compared with AP movement of 3.26 mm (SEM +/- 0.99 mm). Mean longitudinal sciatic nerve movement at the PMT was 3.47 mm (SEM +/- 0.79 mm; n = 27) compared with the PC of 5.22 mm (SEM +/- 0.05 mm; n = 3). The reliability of ultrasound measurement of transverse sciatic nerve movement was fair to excellent (Intraclass correlation coefficient [ICC] = 0.39-0.76) compared with excellent (ICC = 0.75) for analysis of longitudinal movement. Diagnostic ultrasound presents a reliable, noninvasive, real-time, in vivo method for analysis of sciatic nerve movement.
[Neoplasic colonic obstruction: resolution with self-expanding metallic stents].
Jury, Gastón; Amieva, Leandro; Dolan, Martín; Fagalde, Rafael López; Naiderman, Diego; Pastorino, Martín; Jury, Rubén
2014-03-01
The endoscopic placement of self-expanding metallic stents (SEMS) emerges as a therapeutic option for neoplastic colonic obstruction in two situations: as palliative treatment and as a bridge to surgery. The latter can avoid emergency surgery, thus decreasing the rate of ostomies and the mortality and morbidity associated with them. To evaluate the feasibility, safety and benefits of SEMS placement for the treatment of neoplastic colorectal obstruction. Between August 2008 and June 2012, we included in this prospective, longitudinal, descriptive and observational study all the patients suffering from colorectal neoplasia who were subjected to SEMS placement by the same group ofendoscopists. Nitinol SEMS were inserted under endoscopic vision and radioscopic control. Twenty seven SEMS were inserted in 27 patients, 61% of them were male and the average age was 70 years old. Symptoms of colonic suboclussion or obstruction were found in 92% of patients, 88% of the lesions were located in the left-side colon, 41% of cases were performed on an ambulatory basis and 65% of stenting was carried out for palliative purposes. The average time of hospitalization was 6,46 days. Technical and clinical success were 93% and 100%, respectively. Minor complications were observed in 11% of patients. Colonic stenting was followed by elective surgery within one month, by a laparoscopic technique in most cases. The placement of SEMS arises as a safe and effective alternative to palliative surgery or as a bridge to elective surgery.
Shiomi, Hideyuki; Matsumoto, Kazuya; Isayama, Hiroyuki
2017-04-01
Acute cholangitis as a result of common bile duct stones can be managed; however, cholangitis caused by occlusion with a biliary self-expandable metallic stent (SEMS) in patients with an unresectable malignant biliary obstruction has not been fully discussed. The acute cholangitis clinical guidelines (Tokyo Guidelines 2013) recommend following the same procedure as that used for cholangitis; however, the patient's condition, including performance status, tumor extension or staging, and prognosis must be considered. Most physicians manage cholangitis from a SEMS occlusion using a two-step procedure. They insert endoscopic drainage with a plastic stent or insert a nasobiliary drainage tube, which does not exacerbate sepsis. Addition or replacement of a biliary SEMS is required in many cases depending on the cause of the occlusion. Tumor ingrowth through the stent mesh is common in uncovered SEMS and requires placement of another stent in an in-stent method. However, covered SEMS tends to be occluded by sludge, so it must be replaced because of the bacterial biofilm that forms on the covering membrane. The location of the biliary stricture (hilar or distal) should also be considered. Strategies for managing cholangitis as a result of occlusion by a biliary SEMS remain controversial, so prospective clinical trials are needed. © 2017 The Authors. Digestive Endoscopy © 2017 Japan Gastroenterological Endoscopy Society.
Super-resolution for asymmetric resolution of FIB-SEM 3D imaging using AI with deep learning.
Hagita, Katsumi; Higuchi, Takeshi; Jinnai, Hiroshi
2018-04-12
Scanning electron microscopy equipped with a focused ion beam (FIB-SEM) is a promising three-dimensional (3D) imaging technique for nano- and meso-scale morphologies. In FIB-SEM, the specimen surface is stripped by an ion beam and imaged by an SEM installed orthogonally to the FIB. The lateral resolution is governed by the SEM, while the depth resolution, i.e., the FIB milling direction, is determined by the thickness of the stripped thin layer. In most cases, the lateral resolution is superior to the depth resolution; hence, asymmetric resolution is generated in the 3D image. Here, we propose a new approach based on an image-processing or deep-learning-based method for super-resolution of 3D images with such asymmetric resolution, so as to restore the depth resolution to achieve symmetric resolution. The deep-learning-based method learns from high-resolution sub-images obtained via SEM and recovers low-resolution sub-images parallel to the FIB milling direction. The 3D morphologies of polymeric nano-composites are used as test images, which are subjected to the deep-learning-based method as well as conventional methods. We find that the former yields superior restoration, particularly as the asymmetric resolution is increased. Our super-resolution approach for images having asymmetric resolution enables observation time reduction.
NASA Technical Reports Server (NTRS)
Zhao, Minhua; Ming, Bin; Kim, Jae-Woo; Gibbons, Luke J.; Gu, Xiaohong; Nguyen, Tinh; Park, Cheol; Lillehei, Peter T.; Villarrubia, J. S.; Vladar, Andras E.;
2015-01-01
Despite many studies of subsurface imaging of carbon nanotube (CNT)-polymer composites via scanning electron microscopy (SEM), significant controversy exists concerning the imaging depth and contrast mechanisms. We studied CNT-polyimide composites and, by threedimensional reconstructions of captured stereo-pair images, determined that the maximum SEM imaging depth was typically hundreds of nanometers. The contrast mechanisms were investigated over a broad range of beam accelerating voltages from 0.3 to 30 kV, and ascribed to modulation by embedded CNTs of the effective secondary electron (SE) emission yield at the polymer surface. This modulation of the SE yield is due to non-uniform surface potential distribution resulting from current flows due to leakage and electron beam induced current. The importance of an external electric field on SEM subsurface imaging was also demonstrated. The insights gained from this study can be generally applied to SEM nondestructive subsurface imaging of conducting nanostructures embedded in dielectric matrices such as graphene-polymer composites, silicon-based single electron transistors, high resolution SEM overlay metrology or e-beam lithography, and have significant implications in nanotechnology.
Goldberg, Martin W
2016-01-01
Scanning electron microscopy (SEM) is a technique used to image surfaces. Field emission SEMs (feSEMs) can resolve structures that are ~0.5-1.5 nm apart. FeSEM, therefore is a useful technique for imaging molecular structures that exist at surfaces such as membranes. The nuclear envelope consists of four membrane surfaces, all of which may be accessible for imaging. Imaging of the cytoplasmic face of the outer membrane gives information about ribosomes and cytoskeletal attachments, as well as details of the cytoplasmic peripheral components of the nuclear pore complex, and is the most easily accessed surface. The nucleoplasmic face of the inner membrane is easily accessible in some cells, such as amphibian oocytes, giving valuable details about the organization of the nuclear lamina and how it interacts with the nuclear pore complexes. The luminal faces of both membranes are difficult to access, but may be exposed by various fracturing techniques. Protocols are presented here for the preparation, labeling, and feSEM imaging of Xenopus laevis oocyte nuclear envelopes.
Jiang, Chenchen; Lu, Haojian; Zhang, Hongti; Shen, Yajing; Lu, Yang
2017-01-01
In the past decades, in situ scanning electron microscopy (SEM) has become a powerful technique for the experimental study of low-dimensional (1D/2D) nanomaterials, since it can provide unprecedented details for individual nanostructures upon mechanical and electrical stimulus and thus uncover the fundamental deformation and failure mechanisms for their device applications. In this overview, we summarized recent developments on in situ SEM-based mechanical and electrical characterization techniques including tensile, compression, bending, and electrical property probing on individual nanostructures, as well as the state-of-the-art electromechanical coupling analysis. In addition, the advantages and disadvantages of in situ SEM tests were also discussed with some possible solutions to address the challenges. Furthermore, critical challenges were also discussed for the development and design of robust in situ SEM characterization platform with higher resolution and wider range of samples. These experimental efforts have offered in-depth understanding on the mechanical and electrical properties of low-dimensional nanomaterial components and given guidelines for their further structural and functional applications.
Jiang, Chenchen; Lu, Haojian; Zhang, Hongti
2017-01-01
In the past decades, in situ scanning electron microscopy (SEM) has become a powerful technique for the experimental study of low-dimensional (1D/2D) nanomaterials, since it can provide unprecedented details for individual nanostructures upon mechanical and electrical stimulus and thus uncover the fundamental deformation and failure mechanisms for their device applications. In this overview, we summarized recent developments on in situ SEM-based mechanical and electrical characterization techniques including tensile, compression, bending, and electrical property probing on individual nanostructures, as well as the state-of-the-art electromechanical coupling analysis. In addition, the advantages and disadvantages of in situ SEM tests were also discussed with some possible solutions to address the challenges. Furthermore, critical challenges were also discussed for the development and design of robust in situ SEM characterization platform with higher resolution and wider range of samples. These experimental efforts have offered in-depth understanding on the mechanical and electrical properties of low-dimensional nanomaterial components and given guidelines for their further structural and functional applications. PMID:29209445
SD-SEM: sparse-dense correspondence for 3D reconstruction of microscopic samples.
Baghaie, Ahmadreza; Tafti, Ahmad P; Owen, Heather A; D'Souza, Roshan M; Yu, Zeyun
2017-06-01
Scanning electron microscopy (SEM) imaging has been a principal component of many studies in biomedical, mechanical, and materials sciences since its emergence. Despite the high resolution of captured images, they remain two-dimensional (2D). In this work, a novel framework using sparse-dense correspondence is introduced and investigated for 3D reconstruction of stereo SEM images. SEM micrographs from microscopic samples are captured by tilting the specimen stage by a known angle. The pair of SEM micrographs is then rectified using sparse scale invariant feature transform (SIFT) features/descriptors and a contrario RANSAC for matching outlier removal to ensure a gross horizontal displacement between corresponding points. This is followed by dense correspondence estimation using dense SIFT descriptors and employing a factor graph representation of the energy minimization functional and loopy belief propagation (LBP) as means of optimization. Given the pixel-by-pixel correspondence and the tilt angle of the specimen stage during the acquisition of micrographs, depth can be recovered. Extensive tests reveal the strength of the proposed method for high-quality reconstruction of microscopic samples. Copyright © 2017 Elsevier Ltd. All rights reserved.
Human cardiac telocytes: 3D imaging by FIB-SEM tomography.
Cretoiu, D; Hummel, E; Zimmermann, H; Gherghiceanu, M; Popescu, L M
2014-11-01
Telocyte (TC) is a newly identified type of cell in the cardiac interstitium (www.telocytes.com). TCs are described by classical transmission electron microscopy as cells with very thin and long telopodes (Tps; cellular prolongations) having podoms (dilations) and podomers (very thin segments). TCs' three-dimensional (3D) morphology is still unknown. Cardiac TCs seem to be particularly involved in long and short distance intercellular signalling and, therefore, their 3D architecture is important for understanding their spatial connections. Using focused ion beam scanning electron microscopy (FIB-SEM) we show, for the first time, the whole ultrastructural anatomy of cardiac TCs. 3D reconstruction of cardiac TCs by FIB-SEM tomography confirms that they have long, narrow but flattened (ribbon-like) telopodes, with humps generated by the podoms. FIB-SEM tomography also confirms the network made by TCs in the cardiac interstitium through adherens junctions. This study provides the first FIB-SEM tomography of a human cell type. © 2014 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
Tringali, Andrea; Blero, Daniel; Boškoski, Ivo; Familiari, Pietro; Perri, Vincenzo; Devière, Jacques; Costamagna, Guido
2014-06-01
Removal of biliary Fully Covered Self Expandable Metal Stents can fail due to stent migration and/or hyperplastic ingrowth/overgrowth. A case series of 5 patients with benign biliary strictures (2 post-cholecystectomy, 2 following liver transplantation and 1 related to chronic pancreatitis) is reported. The biliary stricture was treated by temporary insertion of Fully Covered Self Expandable Metal Stents. Stent removal failed due to proximal stent migration and/or overgrowth. Metal stent removal was attempted a few weeks after the insertion of another Fully Covered Metal Stent into the first one. The inner Fully Covered Self Expandable Metal Stent compressed the hyperplastic tissue, leading to the extraction of both the stents in all cases. Two complications were reported as a result of the attempt to stents removal (mild pancreatitis and self-limited haemobilia). In the present series, the "SEMS in SEMS" technique revealed to be effective when difficulties are encountered during Fully Covered Self Expandable Metal Stents removal. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Electricity Submetering on the Cheap: Stick-on Electricity Meters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lanzisera, Steven; Lorek, Michael; Pister, Kristofer
2014-08-17
We demonstrate a low-cost, 21 x 12 mm prototype Stick-on Electricity Meter (SEM) to replace traditional in-circuit-breaker-panel current and voltage sensors for building submetering. A SEM sensor is installed on the external face of a circuit breaker to generate voltage and current signals. This allows for the computation of real and apparent power as well as capturing harmonics created by non-linear loads. The prototype sensor is built using commercially available components, resulting in a production cost of under $10 per SEM. With no highvoltage install work requiring an electrician, home owners or other individuals can install the system in amore » few minutes with no safety implications. This leads to an installed system cost that is much lower than traditional submetering technology.. Measurement results from lab characterization as well as a real-world residential dwelling installation are presented, verifying the operation of our proposed SEM sensor. The SEM sensor can resolve breaker power levels below 10W, and it can be used to provide data for non-intrusive load monitoring systems at full sample rate.« less
Adaniya, Hidehito; Cheung, Martin; Cassidy, Cathal; Yamashita, Masao; Shintake, Tsumoru
2018-05-01
A new SEM-based in-line electron holography microscope has been under development. The microscope utilizes conventional SEM and BF-STEM functionality to allow for rapid searching of the specimen of interest, seamless interchange between SEM, BF-STEM and holographic imaging modes, and makes use of coherent low-energy in-line electron holography to obtain low-dose, high-contrast images of light element materials. We report here an overview of the instrumentation and first experimental results on gold nano-particles and carbon nano-fibers for system performance tests. Reconstructed images obtained from the holographic imaging mode of the new microscope show substantial image contrast and resolution compared to those acquired by SEM and BF-STEM modes, demonstrating the feasibility of high-contrast imaging via low-energy in-line electron holography. The prospect of utilizing the new microscope to image purified biological specimens at the individual particle level is discussed and electron optical issues and challenges to further improve resolution and contrast are considered. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhuang, Wen; Gao, Xuelu
2013-11-15
Surface sediments were collected from the coastal waters of southwestern Laizhou Bay and the rivers it connects with during summer and autumn 2012. The acid-volatile sulfide (AVS) and simultaneously extracted metals (SEM) were measured to assess the sediment quality. The results showed that not all sediments with [SEM]-[AVS]>0 were capable of causing toxicity because the organic carbon is also an important metal-binding phase in sediments. Suppose the sediments had not been disturbed and the criteria of US Environmental Protection Agency had been followed, heavy metals in this area had no adverse biological effects in both seasons except for few riverine samples. The major ingredient of SEM was Zn, whereas the contribution of Cd - the most toxic metal studied - to SEM was <1%. The distributions of AVS and SEM in riverine sediments were more easily affected by anthropogenic activity compared with those in marine sediments. Copyright © 2013 Elsevier Ltd. All rights reserved.
Zaaboub, Noureddine; Helali, Mohamed Amine; Martins, Maria Virgínia Alves; Ennouri, Rym; Béjaoui, Béchir; da Silva, Eduardo Ferreira; El Bour, Monia; Aleya, Lotfi
2016-11-01
Bizerte Lagoon is a southern Mediterranean semi-enclosed lagoon with a maximum depth of 12 m. After assessing sediment quality, the authors report on the physicochemical characteristics of the lagoon's surface sediment using SEM (simultaneously extracted metals) and AVS (acid volatile sulfides) as proxies. Biogeochemical tools are used to investigate the environmental disturbance at the water-sediment interface by means of SEM and AVS to seek conclusions concerning the study area's pollution status. Results confirm accumulation of trace elements in sediment. The use of the SEM-AVS model with organic matter in sediment (ƒOC) confirms possible bioavailability of accumulated trace elements, especially Zn, in the southern part of the lagoon, with organic matter playing an important role in SEM excess correction to affirm a nontoxic total metal sediment state. Individual trace element toxicity is dependent on the bioavailable fraction of SEM Metal on sediment, as is the influence of lagoon inflow from southern water sources on element bioavailability. Appropriate management strategies are highly recommended to mitigate any potential harmful effects on health from this heavy-metal-based pollution.
Wilkerson, J. Michael; Iantaffi, Alex; Smolenski, Derek J.; Horvath, Keith J.; Simon Rosser, B. R.
2014-01-01
To inform HIV/STI prevention messaging, we used cross-sectional data from 1,231 MSM to examine the acceptability of strategies for delivering prevention messages in sexually explicit media (SEM). The majority of participants (83%) found it acceptable to include prevention messages in SEM. A latent profile analysis identified three classifications of men with similar views on the acceptability of strategies. Compared to men endorsing some strategies (54%), men endorsing all strategies (29%) were younger (PORadj=0.56 [0.39, 0.79]) and preferred viewing SEM in which the actors used condoms for anal sex (PORadj=1.53 [1.05, 2.23]). Men endorsing no strategies (17%) were of similar age to men endorsing some, but were more likely to prefer viewing SEM in which the actors did not use condoms (PORadj=2.44 [1.43, 4.16]) and to report engaging in insertive unprotected anal sex within the last 3 months (PORadj=2.03 [1.11, 3.70]). Opportunities exist to use SEM for HIV/STI prevention. PMID:23837809
Silane surface modification for improved bioadhesion of esophageal stents
Karakoy, Mert; Gultepe, Evin; Pandey, Shivendra; Khashab, Mouen A.; Gracias, David H.
2014-01-01
Stent migration occurs in 10-40% of patients who undergo placement of esophageal stents, with higher migration rates seen in those treated for benign esophageal disorders. This remains a major drawback of esophageal stent therapy. In this paper, we propose a new surface modification method to increase the adhesion between self-expandable metallic stents (SEMS) and tissue while preserving their removability. Taking advantage of the well-known affinity between epoxide and amine terminated silane coupling agents with amine and carboxyl groups that are abundant in proteins and related molecules in the human body; we modified the surfaces of silicone coated esophageal SEMS with these adhesive self-assembled monolayers (SAMs). We utilized vapor phase silanization to modify the surfaces of different substrates including PDMS strips and SEMS, and measured the force required to slide these substrates on a tissue piece. Our results suggest that surface modification of esophageal SEMS via covalent attachment of protein-binding coupling agents improves adhesion to tissue and could offer a solution to reduce SEMS migration while preserving their removability. PMID:25663731
Identification of a potential toxic hot spot associated with AVS spatial and seasonal variation.
Campana, O; Rodríguez, A; Blasco, J
2009-04-01
In risk assessment of aquatic sediments, much attention is paid to the difference between acid-volatile sulfide (AVS) and simultaneously extracted metals (SEMs) as indicators of metal availability. Ten representative sampling sites were selected along the estuary of the Guadalete River. Surficial sediments were sampled in winter and summer to better understand SEM and AVS spatial and seasonal distributions and to establish priority risk areas. Total SEM concentration (SigmaSEM) ranged from 0.3 to 4.7 micromol g(-1). It was not significantly different between seasons, however, it showed a significant difference between sampling stations. AVS concentrations were much more variable, showing significant spatial and temporal variations. The values ranged from 0.8 to 22.4 micromol g(-1). The SEM/AVS ratio was found to be <1 at all except one station located near the mouth of the estuary. The results provided information on a potential pollution source near the mouth of the estuary, probably associated with vessel-related activities carried out in a local harbor area located near the station.
NASA Astrophysics Data System (ADS)
Dcruz, Noella L.
2014-07-01
We occasionally include projects in our learner-centered introductory astronomy college course to enable non-science major students explore some astronomical concepts in more detail than otherwise. Such projects also highlight ongoing or upcoming astronomical events. We hope that students will feel more interested in astronomy through projects tied to astronomical events. In Spring 2012, we offered short essays focused on eclipses, transits and occultations to promote the rare transit of Venus that occurred on June 5th, 2012. We asked students to write two short essays from three that were offered. The essays contained descriptive and conceptual parts. They were meant to serve as teaching tools. 62% of 106 essays from 55 students earned A, B or C grades. 21% of 47 feedback survey respondents felt the essays increased their interest in astronomy. 49% of respondents felt that the essays were not educationally beneficial and should not be offered again. The most common written response to our survey indicated that students need more guidance and better preparation in writing successful essays. Since students found the conceptual parts of the essays difficult, in the future we will provide relevant activities prior to essay deadlines to help students create successful essays. Ocasionalmente, incluimos proyectos en nuestro curso de introducción a la astronomía universitario centrado en el alumno para permitir que los estudiantes de carreras no científicas exploren algunos conceptos astronómicos en más detalle que lo habitual. Estos proyectos también ponen en relevancia eventos astronómicos en curso o futuros. Esperamos que los estudiantes se sientan más interesados en la astronomía a través de proyectos vinculados a eventos astronómicos. En el período de primavera de 2012 (EUA), propusimos breves ensayos centrados en los eclipses, tránsitos y ocultaciones para promover el raro tránsito de Venus que se produjo el 5 de junio de 2012. Le pedimos a los estudiantes que escribieran dos ensayos cortos de tres que se proponían. Los ensayos contenían partes descriptivas y conceptuales. Los mismos estaban destinados a servir como herramientas de enseñanza. 62% de los 106 ensayos de 55 estudiantes obtuvo grados A, B o C. 21% de los 47 encuestados que respondieron al cuestionario posterior consideró que los ensayos aumentaron su interés por la astronomía. 49% de los encuestados consideró que los ensayos no eran educacionalmente útiles y que no deben ser propuestos de nuevo. Las respuestas escritas más comunes a nuestra encuesta indicaran que los estudiantes necesitan más orientación y una mejor preparación en la redacción de ensayos exitosos. Dado que los estudiantes encontraron las piezas conceptuales de los ensayos difíciles, en el futuro vamos a ofrecer actividades pertinentes antes de los plazos de redacción para ayudar a los estudiantes a crear ensayos de mayor calidad. Nós ocasionalmente incluímos projetos em nosso curso universitário introdutório centrado no aluno para permitir aos estudantes que pertencem às carreiras não científicas explorar alguns conceitos astronômicos em mais detalhes do que o normal. Tais projetos também enfatizam eventos astronômicos em curso ou futuros. Esperamos que os alunos se sintam mais interessados na astronomia através de projetos ligados a eventos astronômicos. No termo de Primavera de 2012 (EUA), propomos ensaios curtos focados em eclipses, trânsitos e ocultações para promover o raro trânsito de Vênus que ocorreu no dia 5 de junho de 2012. Pedimos aos alunos que escrevessem dois ensaios curtos dentre três que foram propostos. Os ensaios continham partes descritivas e conceituais. Eles foram feitos para servir como ferramentas de ensino. 62% de 106 ensaios de 55 alunos ganhou graus A, B ou C. 21% dos 47 entrevistados que responderam ao levantamento posterior sentiu que os ensaios aumentaram seu interesse na astronomia. 49% dos inquiridos consideraram que os ensaios não eram benéficos para a educação e que não devem ser propostos novamente. As respostas escritas mais comuns da nossa pesquisa indicaram que os alunos precisam de mais orientação e melhor preparação para escrever ensaios bem sucedidos. Como os alunos consideraram difíceis os aspectos conceituais dos ensaios, no futuro iremos fornecer atividades relevantes antes dos ensaios para ajudar os alunos a escrevê-los com sucesso.
Novel biliary self-expanding metal stents: indications and applications.
Blero, Daniel; Huberty, Vincent; Devière, Jacques
2015-03-01
Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.
Mathematical model of the seismic electromagnetic signals (SEMS) in non crystalline substances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dennis, L. C. C.; Yahya, N.; Daud, H.
The mathematical model of seismic electromagnetic waves in non crystalline substances is developed and the solutions are discussed to show the possibility of improving the electromagnetic waves especially the electric field. The shear stress of the medium in fourth order tensor gives the equation of motion. Analytic methods are selected for the solutions written in Hansen vector form. From the simulated SEMS, the frequency of seismic waves has significant effects to the SEMS propagating characteristics. EM waves transform into SEMS or energized seismic waves. Traveling distance increases once the frequency of the seismic waves increases from 100% to 1000%. SEMSmore » with greater seismic frequency will give seismic alike waves but greater energy is embedded by EM waves and hence further distance the waves travel.« less
Synchronized voltage contrast display analysis system
NASA Technical Reports Server (NTRS)
Johnston, M. F.; Shumka, A.; Miller, E.; Evans, K. C. (Inventor)
1982-01-01
An apparatus and method for comparing internal voltage potentials of first and second operating electronic components such as large scale integrated circuits (LSI's) in which voltage differentials are visually identified via an appropriate display means are described. More particularly, in a first embodiment of the invention a first and second scanning electron microscope (SEM) are configured to scan a first and second operating electronic component respectively. The scan pattern of the second SEM is synchronized to that of the first SEM so that both simultaneously scan corresponding portions of the two operating electronic components. Video signals from each SEM corresponding to secondary electron signals generated as a result of a primary electron beam intersecting each operating electronic component in accordance with a predetermined scan pattern are provided to a video mixer and color encoder.
Snow crystal imaging using scanning electron microscopy: III. Glacier ice, snow and biota
Rango, A.; Wergin, W.P.; Erbe, E.F.; Josberger, E.G.
2000-01-01
Low-temperature scanning electron microscopy (SEM) was used to observe metamorphosed snow, glacial firn, and glacial ice obtained from South Cascade Glacier in Washington State, USA. Biotic samples consisting of algae (Chlamydomonas nivalis) and ice worms (a species of oligochaetes) were also collected and imaged. In the field, the snow and biological samples were mounted on copper plates, cooled in liquid nitrogen, and stored in dry shipping containers which maintain a temperature of -196??C. The firn and glacier ice samples were obtained by extracting horizontal ice cores, 8 mm in diameter, at different levels from larger standard glaciological (vertical) ice cores 7.5 cm in diameter. These samples were cooled in liquid nitrogen and placed in cryotubes, were stored in the same dry shipping container, and sent to the SEM facility. In the laboratory, the samples were sputter coated with platinum and imaged by a low-temperature SEM. To image the firn and glacier ice samples, the cores were fractured in liquid nitrogen, attached to a specimen holder, and then imaged. While light microscope images of snow and ice are difficult to interpret because of internal reflection and refraction, the SEM images provide a clear and unique view of the surface of the samples because they are generated from electrons emitted or reflected only from the surface of the sample. In addition, the SEM has a great depth of field with a wide range of magnifying capabilities. The resulting images clearly show the individual grains of the seasonal snowpack and the bonding between the snow grains. Images of firn show individual ice crystals, the bonding between the crystals, and connected air spaces. Images of glacier ice show a crystal structure on a scale of 1-2 mm which is considerably smaller than the expected crystal size. Microscopic air bubbles, less than 15 ??m in diameter, clearly marked the boundaries between these crystal-like features. The life forms associated with the glacier were easily imaged and studied. The low-temperature SEM sample collecting and handling methods proved to be operable in the field; the SEM analysis is applicable to glaciological studies and reveals details unattainable by conventional light microscopic methods.Low temperature scanning electron microscopy (SEM) was used to observe metamorphosed snow, glacial firn, and glacial ice obtained from South Cascade Glacier in Washington State, USA. Biotic samples consisting of algae and ice worms were also collected and imaged. The SEM images provide a clear and unique view of the surface of the samples because they are generated from electrons emitted or reflected only from the surface of the sample. The SEM has a great depth of field with a wide range of magnifying capabilities.
Studies of Al-Ti Alloys by SEM
NASA Astrophysics Data System (ADS)
Yildiz, K.; Atici, Y.; Keşlİ Oǧlu, K.; Yaşar, E.
2007-04-01
Al-Ti (1, 2 wt. %) alloys were investigated by Scanning Electron Microscopy (SEM). SEM observations and energy-dispersive x-ray analyses (EDX) showed that the phase structure of Al-Ti (1 %) alloy at 165 μm/s is composed of Al matrix and C, Ni, Fe and Si particles and the Al-Ti (1 %) alloys at 16 and 8 μm/s have only the Al matrix and C particles. It was also found that the Al-Ti (2 %) form the Al matrix and intermetallic TiAl.
Solid Lubricated Rolling Element Bearings
1980-02-15
ball paths (as received), at various SEM magnifications and EDX scrutiny 17 i. ■.- ■■ ••.■■ ■? • r 8. TMI TiC/MoS^ sputtered...MoS? removed with Oakite 126 HD), at various SEM magmtications and EDX scrutiny 19 10. TMI TiC/MoS^ sputtered 52100 gyro bearing inner race...ball path (MoS^ removed with Oakite 126 HD), at various SEM magnifications and EDX scrutiny 20 11. TMI TiC/MoS^ sputtered 52100 gyro bearing
2011-09-01
glancing angle X - ray diffraction (GAXRD), atomic force microscopy (AFM), scanning electron microscopy (SEM), and electrochemical...Emission SEM FWHM full width at half maximum GAXRD glancing angle X - ray diffraction H3COCH2CH2OH 2-methoxyethanol LiMn2O4 lithium manganese oxide...were characterized by scanning electron microscopy (SEM), X - ray diffraction (XRD), and atomic force microscopy (AFM). In addition,
Brumbaugh, William G.; Hammerschmidt, Chad R.; Zanella, Luciana; Rogevich, Emily; Salata, Gregory; Bolek, Radoslaw
2011-01-01
An interlaboratory comparison of acid-volatile sulfide (AVS) and simultaneously extracted nickel (SEM_Ni) measurements of sediments was conducted among five independent laboratories. Relative standard deviations for the seven test samples ranged from 5.6 to 71% (mean = 25%) for AVS and from 5.5 to 15% (mean = 10%) for SEM_Ni. These results are in stark contrast to a recently published study that indicated AVS and SEM analyses were highly variable among laboratories.
Yoshikawa, Yukihiro; Yoshikawa, Masato; Kawabata, Ryohei; Yoshida, Yuta; Kawada, Masahiro; Yasuyama, Akinobu; Watase, Chikashi; Koga, Chikato; Hitora, Toshiki; Murakami, Masahiro; Hirota, Masaki; Ikenaga, Masakazu; Shimizu, Junzo; Hasegawa, Junichi
2015-11-01
A 68-year-old man underwent esophagectomy for early esophageal cancer. Postoperative upper gastrointestinal series and esophagogastroduodenoscopy showed gastric tube stenosis. To improve passage, a removable self-expandable metallic stent (SEMS) was placed across the stenotic lesion. Two weeks later, the stent was removed, and passage through the gastric tube improved. The patient has no symptoms of stenosis. A removable SEMS could be an option for the treatment of gastric tube stenosis after esophagectomy.
Madden, Gary T.; Schmidt, Dwight Lyman; Whitmore, Frank C.
1983-01-01
A lower jaw fragment with its last molar (M/3) from the Baid formation in Wadi Sabya, southwestern Saudi Arabia, represents the first recorded occurrence in the Arabian Peninsula of an anthracotheriid artiodactyl (hippo-like, even-toed ungulate). This fossil is identified as a primitive species of Masritherium, a North and East African genus restricted, previously to the later early Miocene. This identification indicates that the age of the Baid formation, long problematical, is early Miocene and, moreover, shows that the age of the fossil site is earliest Miocene (from 25 to 21Ma). The Wadi Sabya anthracothere is the first species of fossil mammal recorded from western Saudi Arabia, and more important, it indicates an early Miocene age for the volcanic deposits of a continental rift-valley that preceded the initial sea-floor spreading of the Red Sea.
Bejan, Cosmin Adrian; Wei, Wei-Qi; Denny, Joshua C
2015-01-01
Objective To evaluate the contribution of the MEDication Indication (MEDI) resource and SemRep for identifying treatment relations in clinical text. Materials and methods We first processed clinical documents with SemRep to extract the Unified Medical Language System (UMLS) concepts and the treatment relations between them. Then, we incorporated MEDI into a simple algorithm that identifies treatment relations between two concepts if they match a medication-indication pair in this resource. For a better coverage, we expanded MEDI using ontology relationships from RxNorm and UMLS Metathesaurus. We also developed two ensemble methods, which combined the predictions of SemRep and the MEDI algorithm. We evaluated our selected methods on two datasets, a Vanderbilt corpus of 6864 discharge summaries and the 2010 Informatics for Integrating Biology and the Bedside (i2b2)/Veteran's Affairs (VA) challenge dataset. Results The Vanderbilt dataset included 958 manually annotated treatment relations. A double annotation was performed on 25% of relations with high agreement (Cohen's κ = 0.86). The evaluation consisted of comparing the manual annotated relations with the relations identified by SemRep, the MEDI algorithm, and the two ensemble methods. On the first dataset, the best F1-measure results achieved by the MEDI algorithm and the union of the two resources (78.7 and 80, respectively) were significantly higher than the SemRep results (72.3). On the second dataset, the MEDI algorithm achieved better precision and significantly lower recall values than the best system in the i2b2 challenge. The two systems obtained comparable F1-measure values on the subset of i2b2 relations with both arguments in MEDI. Conclusions Both SemRep and MEDI can be used to extract treatment relations from clinical text. Knowledge-based extraction with MEDI outperformed use of SemRep alone, but superior performance was achieved by integrating both systems. The integration of knowledge-based resources such as MEDI into information extraction systems such as SemRep and the i2b2 relation extractors may improve treatment relation extraction from clinical text. PMID:25336593
A two scale analysis of tight sandstones
NASA Astrophysics Data System (ADS)
Adler, P. M.; Davy, C. A.; Song, Y.; Troadec, D.; Hauss, G.; Skoczylas, F.
2015-12-01
Tight sandstones have a low porosity and a very small permeability K. Available models for K do not compare well with measurements. These sandstones are made of SiO_2 grains, with a typical size of several hundreds of micron. These grains are separated by a network of micro-cracks, with sizes ranging between microns down to tens of nm. Therefore, the structure can be schematized by Voronoi polyhedra separated by plane and permeable polygonal micro-cracks. Our goal is to estimate K based on a two scale analysis and to compare the results to measurements. For a particular sample [2], local measurements on several scales include FIB/SEM [3], CMT and 2D SEM. FIB/SEM is selected because the peak pore size given by Mercury Intrusion Porosimetry is of 350nm. FIB/SEM imaging (with 50 nm voxel size) identifies an individual crack of 180nm average opening, whereas CMT provides a connected porosity (individual crack) for 60 nm voxel size, of 4 micron average opening. Numerical modelling is performed by combining the micro-crack network scale (given by 2D SEM) and the 3D micro-crack scale (given by either FIB/SEM or CMT). Estimates of the micro-crack density are derived from 2D SEM trace maps by counting the intersections with scanlines, the surface density of traces, and the number of fracture intersections. K is deduced by using a semi empirical formula valid for identical, isotropic and uniformly distributed fractures [1]. This value is proportional to the micro-crack transmissivity sigma. Sigma is determined by solving the Stokes equation in the micro-cracks measured by FIB/SEM or CMT. K is obtained by combining the two previous results. Good correlation with measured values on centimetric plugs is found when using sigma from CMT data. The results are discussed and further research is proposed. [1] Adler et al, Fractured porous media, Oxford Univ. Press, 2012. [2] Duan et al, Int. J. Rock Mech. Mining Sci., 65, p75, 2014. [3] Song et al, Marine and Petroleum Eng., 65, p63, 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaka, Fowzia
This method describes the characterization of HE powders by Scanning Electron Microscopy (SEM). HE particles are dispersed onto an aluminum standard SEM specimen mount. Electron micrographs are collected at various magnifications (150 to 10,000 X) depending on HE particle size.
[Revisiting the chemical diversity in prostatic calculi: a SEM and FT-IR investigation].
Dessombz, A; Méria, P; Bazin, D; Foy, E; Rouzière, S; Weil, R; Daudon, M
2011-12-01
Revisiting the chemical diversity of the crystalline phases of prostatic calculi by means of SEM and FT-IR analysis. A set of 32 prostatic calculi has been studied by FT-IR and SEM. FT-IR analysis has determined the chemical composition of each prostatic calculus and the SEM observation has described the morphology of the calculi surfaces and layers. Infrared analysis revealed that 90.7% of the stones were mainly composed of calcium phosphates. However, several mineral phases previously not reported in prostatic calculi were observed, as brushite or octocalcium phosphate pentahydrate. Prostatic calculi exhibited a diversity of crystalline composition and morphology. As previously reported for urinary calculi, relationships between composition and morphology of prostatic stones and étiopathogenic conditions could be of interest in clinical practice. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
A history of scanning electron microscopy developments: towards "wet-STEM" imaging.
Bogner, A; Jouneau, P-H; Thollet, G; Basset, D; Gauthier, C
2007-01-01
A recently developed imaging mode called "wet-STEM" and new developments in environmental scanning electron microscopy (ESEM) allows the observation of nano-objects suspended in a liquid phase, with a few manometers resolution and a good signal to noise ratio. The idea behind this technique is simply to perform STEM-in-SEM, that is SEM in transmission mode, in an environmental SEM. The purpose of the present contribution is to highlight the main advances that contributed to development of the wet-STEM technique. Although simple in principle, the wet-STEM imaging mode would have been limited before high brightness electron sources became available, and needed some progresses and improvements in ESEM. This new technique extends the scope of SEM as a high-resolution microscope, relatively cheap and widely available imaging tool, for a wider variety of samples.
Application of the SEM to the measurement of solar cell parameters
NASA Technical Reports Server (NTRS)
Weizer, V. G.; Andrews, C. W.
1977-01-01
A pair of techniques are described which make use of the SEM to measure, respectively, the minority carrier diffusion length and the metallurgical junction depth in silicon solar cells. The former technique permits the measurement of the true bulk diffusion length through the application of highly doped field layers to the back surfaces of the cells being investigated. The technique yields an absolute value of the diffusion length from a knowledge of the collected fraction of the injected carriers and the cell thickness. It is shown that the secondary emission contrast observed in the SEM on a reverse-biased diode can depict the location of the metallurgical junction if the diode has been prepared with the proper beveled geometry. The SEM provides the required contrast and the option of high magnification, permitting the measurement of extremely shallow junction depths.
Pinteala, Tudor; Chiriac, Anca Eduard; Rosca, Irina; Larese Filon, Francesca; Pinteala, Mariana; Chiriac, Anca; Podoleanu, Cristian; Stolnicu, Simona; Coros, Marius Florin; Coroaba, Adina
2017-01-01
Background Scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) techniques have been used in various fields of medical research, including different pathologies of the nails; however, no studies have focused on obtaining high-resolution microscopic images and elemental analysis of disorders caused by synthetic nails and acrylic adhesives. Methods Damaged/injured fingernails caused by the use of acrylate glue and synthetic nails were investigated using SEM and EDX methods. Results SEM and EDX proved that synthetic nails, acrylic glue, and nails damaged by contact with acrylate glue have a different morphology and different composition compared to healthy human nails. Conclusions SEM and EDX analysis can give useful information about the aspects of topography (surface sample), morphology (shape and size), hardness or reflectivity, and the elemental composition of nails. PMID:28232921
High resolution SEM characterization of nano-precipitates in ODS steels.
Jóźwik, Iwona; Strojny-Nędza, Agata; Chmielewski, Marcin; Pietrzak, Katarzyna; Kurpaska, Łukasz; Nosewicz, Szymon
2018-05-01
The performance of the present-day scanning electron microscopy (SEM) extends far beyond delivering electronic images of the surface topography. Oxide dispersion strengthened (ODS) steel is on of the most promising materials for the future nuclear fusion reactor because of its good radiation resistance, and higher operation temperature up to 750°C. The microstructure of ODS should not exceed tens of nm, therefore there is a strong need in a fast and reliable technique for their characterization. In this work, the results of low-kV SEM characterization of nanoprecipitates formed in the ODS matrix are presented. Application of highly sensitive photo-diode BSE detector in SEM imaging allowed for the registration of single nm-sized precipitates in the vicinity of the ODS alloys. The composition of the precipitates has been confirmed by TEM-EDS. © 2018 Wiley Periodicals, Inc.
Special raster scanning for reduction of charging effects in scanning electron microscopy.
Suzuki, Kazuhiko; Oho, Eisaku
2014-01-01
A special raster scanning (SRS) method for reduction of charging effects is developed for the field of SEM. Both a conventional fast scan (horizontal direction) and an unusual scan (vertical direction) are adopted for acquiring raw data consisting of many sub-images. These data are converted to a proper SEM image using digital image processing techniques. About sharpness of the image and reduction of charging effects, the SRS is compared with the conventional fast scan (with frame-averaging) and the conventional slow scan. Experimental results show the effectiveness of SRS images. By a successful combination of the proposed scanning method and low accelerating voltage (LV)-SEMs, it is expected that higher-quality SEM images can be more easily acquired by the considerable reduction of charging effects, while maintaining the resolution. © 2013 Wiley Periodicals, Inc.
Hobo, Seiji; Niwa, Hidekazu; Oku, Kazuomi
2012-03-01
Loop-mediated isothermal amplification (LAMP) constitutes a potentially valuable diagnostic tool for rapid diagnosis of contagious diseases. In this study, we developed a novel LAMP method (seM-LAMP) to detect the seM gene of Streptococcus equi subsp. equi (S. equi), the causative agent of strangles in equids. The seM-LAMP successfully amplified the target sequence of the seM gene at 63°C within 60 min. The sensitivity of the seM-LAMP was slightly lower than the 2nd reaction of the seM semi-nested PCR. To evaluate the species specificity of the seM-LAMP, we tested 100 S. equi and 189 non-S. equi strains. Significant amplification of the DNA originating from S. equi was observed within 60 min incubation, but no amplification of non-S. equi DNA occurred. The results were identical to those of seM semi-nested PCR. To investigate the clinical usefulness of the methods, the seM-LAMP and the seM semi-nested PCR were used to screen 590 nasal swabs obtained during an outbreak of strangles. Both methods showed that 79 and 511 swabs were S. equi positive and negative, respectively, and the results were identical to those of the culture examination. These results indicate that the seM-LAMP is potentially useful for the reliable routine diagnosis of Streptococcus equi subsp. equi infections.
Novel antireflux covered metal stent for recurrent occlusion of biliary metal stents: a pilot study.
Hamada, Tsuyoshi; Isayama, Hiroyuki; Nakai, Yousuke; Kogure, Hirofumi; Togawa, Osamu; Kawakubo, Kazumichi; Yamamoto, Natsuyo; Ito, Yukiko; Sasaki, Takashi; Tsujino, Takeshi; Sasahira, Naoki; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko
2014-03-01
Feasibility of antireflux metal stent (ARMS), designed to prevent duodenobiliary reflux, was reported in patients with distal malignant biliary obstruction. In this prospective pilot study, we aimed to evaluate a newly designed ARMS as a reintervention for self-expandable metallic stent (SEMS) occlusion believed to be caused by duodenobiliary reflux. Patients with non-resectable distal malignant biliary obstruction were included in whom a prior SEMS was occluded as a result of sludge or food impaction between March 2010 and January 2012 at two Japanese tertiary referral centers. The occluded SEMS were endoscopically removed, if possible, and subsequently replaced by a newly designed ARMS. We evaluated the technical success rate and complications of ARMS and compared the time to occlusion of ARMS with that of prior SEMS. A total of 13 patients were included. ARMS was successfully placed in all patients in a single procedure. No procedure-related complications were identified. ARMS occlusion occurred in two patients (15%), the causes of which were sludge in one patient and unknown in the other. ARMS migration occurred in four patients (31%). ARMS patency time was significantly longer than that of prior SEMS (median, not available vs 58 days; P = 0.039). This newly designed ARMS is a technically feasible, safe, and effective reintervention for SEMS occlusion as a result of sludge or food impaction. An anti-migration mechanism to improve the outcomes of ARMS should be considered. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Younis, Alaa M; El-Zokm, Gehan M; Okbah, Mohamed A
2014-06-01
In risk assessment of aquatic sediments, the immobilizing effect of acid-volatile sulfide (AVS) on trace metals is a principal control on availability and associated toxicity of metals to aquatic biota, which reduces metal bioavailability and toxicity by binding and immobilizing metals as insoluble sulfides. Spatial variation pattern of AVS, simultaneously extracted metals (SEM), and sediment characteristics were studied for the first time in surface sediment samples (0-20 cm) from 43 locations in Egyptian northern delta lagoons (Manzalah, Burullus, and Maryut) as predictors of the bioavailability of some divalent metals (Cu, Zn, Cd, Pb, and Ni) in sediments as well as indicators of metal toxicity in anaerobic sediments. The results indicated that the ∑SEM (Cu + Zn + Cd + Pb + Ni) values in sediments of lagoon Burullus had higher concentrations than those of Maryut and Manzalah. In contrast, AVS concentrations were considerably higher in lagoons Manzalah and Maryut and seemed to be consistent with the increase in organic matter than lagoon Burullus. Generally, the average concentrations of the SEM in all lagoons were in the order of Zn > Cu > Ni > Pb > Cd. The ratios of ∑SEM/AVS were less than 1 at all the sampling stations except at one station in lagoon Maryut as well as four stations located in lagoon Burullus (∑SEM/AVS > 1), which suggests that the metals have toxicity potential in these sediments. Therefore, SEM concentrations probably are better indicators of the metal bioavailability in sediments than the conventional total metal concentrations.
NASA Astrophysics Data System (ADS)
Lee, Kyung M.; Yedur, Sanjay; Henrichs, Sven; Tavassoli, Malahat; Baik, Kiho
2007-03-01
Evaluation of lithography process or stepper involves very large quantity of CD measurements and measurement time. In this paper, we report on a application of Scatterometry based metrology for evaluation of binary photomask lithography. Measurements were made on mask level with ODP scatterometer then on wafer with CD-SEM. 4 to 1 scaling from mask to wafer means 60nm line on wafer translates to 240nm on mask, easily measurable on ODP. Calculation of scatterometer profile information was performed by a in-situ library-based analysis (5sec/site). We characterized the CD uniformity, linearity, and metal film thickness uniformity. Results show that linearity measured from fixed-pitch, varying line/space ratio targets show good correlation to top-down CD-SEM with R2 of more than 0.99. ODP-SEM correlation results for variable pitch shows that careful examination of scatterometer profile results in order to obtain better correlation to CD SEM, since both tools react differently to the target profile variation. ODP results show that global CD distribution is clearly measurable with less outliers compared to CD SEM data. This is thought to be due to 'averaging' effect of scatterometer. The data show that Scatterometry provides a nondestructive and faster mean of characterizing lithography stepper performanceprofiles. APSM 1st level (before Cr removal) 'dual-space' CDs and EPSM rectangular contacts were also measured with and results demonstrates that Scatterometer is capable of measuring these targets with reasonable correlation to SEM.
FIB-SEM imaging of carbon nanotubes in mouse lung tissue.
Købler, Carsten; Saber, Anne Thoustrup; Jacobsen, Nicklas Raun; Wallin, Håkan; Vogel, Ulla; Qvortrup, Klaus; Mølhave, Kristian
2014-06-01
Ultrastructural characterisation is important for understanding carbon nanotube (CNT) toxicity and how the CNTs interact with cells and tissues. The standard method for this involves using transmission electron microscopy (TEM). However, in particular, the sample preparation, using a microtome to cut thin sample sections for TEM, can be challenging for investigation of regions with agglomerations of large and stiff CNTs because the CNTs cut with difficulty. As a consequence, the sectioning diamond knife may be damaged and the uncut CNTs are left protruding from the embedded block surface excluding them from TEM analysis. To provide an alternative to ultramicrotomy and subsequent TEM imaging, we studied focused ion beam scanning electron microscopy (FIB-SEM) of CNTs in the lungs of mice, and we evaluated the applicability of the method compared to TEM. FIB-SEM can provide serial section volume imaging not easily obtained with TEM, but it is time-consuming to locate CNTs in the tissue. We demonstrate that protruding CNTs after ultramicrotomy can be used to locate the region of interest, and we present FIB-SEM images of CNTs in lung tissue. FIB-SEM imaging was applied to lung tissue from mice which had been intratracheally instilled with two different multiwalled CNTs; one being short and thin, and the other longer and thicker. FIB-SEM was found to be most suitable for detection of the large CNTs (Ø ca. 70 nm), and to be well suited for studying CNT agglomerates in biological samples which is challenging using standard TEM techniques.
Comparison of 3 tall fescue-based stocker systems.
Bailey, N J; Kallenbach, R L
2010-05-01
A 2-yr production study was conducted to evaluate 3 systems of growing stocker calves under rotational stocking. One group of steers was stocked on pasture from early April to mid August (spring-stocked steers = SSS), and another group of steers was stocked from early July to late October (fall-stocked steers = FSS). Steers were stratified by BW (n = 72, BW = 229 +/- 11 kg for SSS; n = 72, BW = 248 +/- 18 kg for FSS) and randomly assigned to 1 of 3 treatments. The 3 treatments were 1) rotationally stocked only (control; CON), steers rotated to a new paddock as forage availability dropped below acceptable levels in the occupied paddock; 2) rotationally stocked with distillers grains (DIST); this was the same as CON except steers were supplemented with varying amounts of distillers dried grains with solubles (DDGS) based on forage nutritive value; and 3) rotationally stocked with round-bale silage (SIL); excess forage in spring was harvested and stored as round-bale silage and fed back as needed. Total BW gain/ha over the entire grazing season did not differ between DIST and SIL (P = 0.09) steers, but both were greater than CON (P < 0.01). Total BW gain/ha for DIST, SIL, and CON was 459 (SEM = 11.5), 402 (SEM = 31.0), and 276 (SEM = 26.2) kg, respectively. For ADG, there was a group x year (P < 0.01) and group x treatment (P = 0.02) interaction. Steer ADG for SSS did not differ between SIL and DIST (P = 0.51), but was greater than the CON (P = 0.01). The ADG for SSS was 0.79 (SEM = 0.04), 0.81 (SEM = 0.05), and 0.62 (SEM = 0.05) kg for DIST, SIL, and CON, respectively. For the FSS, ADG for all 3 treatments was different (P = 0.02). The FSS ADG was 0.72 (SEM = 0.03), 0.53 (SEM = 0.04), and 0.29 (SEM = 0.04) kg for DIST, SIL, and CON, respectively. The only treatment with equivalent (P = 0.07) ADG between early and late-stocked steers (SSS vs. FSS) was DIST. Adjusting the amount of DDGS supplemented to steers based on forage nutritive value resulted in consistent BW gains throughout the grazing study, whereas steers in the SIL and CON treatments gained less BW during the latter portion of the season. Controlling forage maturity by removal in the SIL treatment resulted in total BW gains/ha that were not different than the DIST treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ogura, Toshihiko, E-mail: t-ogura@aist.go.jp
2009-03-06
The indirect secondary electron contrast (ISEC) condition of the scanning electron microscopy (SEM) produces high contrast detection with minimal damage of unstained biological samples mounted under a thin carbon film. The high contrast image is created by a secondary electron signal produced under the carbon film by a low acceleration voltage. Here, we show that ISEC condition is clearly able to detect unstained bacteriophage T4 under a thin carbon film (10-15 nm) by using high-resolution field emission (FE) SEM. The results show that FE-SEM provides higher resolution than thermionic emission SEM. Furthermore, we investigated the scattered electron area within themore » carbon film under ISEC conditions using Monte Carlo simulation. The simulations indicated that the image resolution difference is related to the scattering width in the carbon film and the electron beam spot size. Using ISEC conditions on unstained virus samples would produce low electronic damage, because the electron beam does not directly irradiate the sample. In addition to the routine analysis, this method can be utilized for structural analysis of various biological samples like viruses, bacteria, and protein complexes.« less
Takaku, Yasuharu; Suzuki, Hiroshi; Ohta, Isao; Tsutsui, Takami; Matsumoto, Haruko; Shimomura, Masatsugu; Hariyama, Takahiko
2015-01-01
Although extremely useful for a wide range of investigations, the field emission scanning electron microscope (FE-SEM) has not allowed researchers to observe living organisms. However, we have recently reported that a simple surface modification consisting of a thin extra layer, termed ‘NanoSuit’, can keep organisms alive in the high vacuum (10−5 to 10−7 Pa) of the SEM. This paper further explores the protective properties of the NanoSuit surface-shield. We found that a NanoSuit formed with the optimum concentration of Tween 20 faithfully preserves the integrity of an organism's surface without interfering with SEM imaging. We also found that electrostatic charging was absent as long as the organisms were alive, even if they had not been coated with electrically conducting materials. This result suggests that living organisms possess their own electrical conductors and/or rely on certain properties of the surface to inhibit charging. The NanoSuit seems to prolong the charge-free condition and increase survival time under vacuum. These findings should encourage the development of more sophisticated observation methods for studying living organisms in an FE-SEM. PMID:25631998
Integration of a high-NA light microscope in a scanning electron microscope.
Zonnevylle, A C; Van Tol, R F C; Liv, N; Narvaez, A C; Effting, A P J; Kruit, P; Hoogenboom, J P
2013-10-01
We present an integrated light-electron microscope in which an inverted high-NA objective lens is positioned inside a scanning electron microscope (SEM). The SEM objective lens and the light objective lens have a common axis and focal plane, allowing high-resolution optical microscopy and scanning electron microscopy on the same area of a sample simultaneously. Components for light illumination and detection can be mounted outside the vacuum, enabling flexibility in the construction of the light microscope. The light objective lens can be positioned underneath the SEM objective lens during operation for sub-10 μm alignment of the fields of view of the light and electron microscopes. We demonstrate in situ epifluorescence microscopy in the SEM with a numerical aperture of 1.4 using vacuum-compatible immersion oil. For a 40-nm-diameter fluorescent polymer nanoparticle, an intensity profile with a FWHM of 380 nm is measured whereas the SEM performance is uncompromised. The integrated instrument may offer new possibilities for correlative light and electron microscopy in the life sciences as well as in physics and chemistry. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.
Pupal melanization is associated with higher fitness in Spodoptera exigua
Liu, Sisi; Wang, Mo; Li, Xianchun
2015-01-01
Melanism has long been thought to be a habitat adaptation with a fitness cost. Here we reported a homozygous melanic strain (SEM) of Spodoptera exigua (Hübner) (Insecta: Lepidoptera: Noctuidae) established with black pupae spontaneously occurring within a typical laboratory population (SEW). The melanization is expressed globally, and only in the pupal stage. After pupation, the melanic SEM pupae gradually accumulate melanin to become completely black within 6 hours, whereas the wild-type SEW pupae gradually turn yellow-brown. The melanic SEM strain exhibits faster development in all life stages, heavier pupa weight, more mating time, higher fecundity, and accordingly, higher net reproductive rate and population trend index. While no reproductive isolation was observed between the SEM and SEW strains, the mating times per female of the reciprocal crosses and the SEM intracrosses were significantly higher than those of the SEW intracrosses. This represents a rare case of melanization that has fitness gains, rather than costs. Analysis of the life-history traits of this case and 14 previously reported cases of insect melanism indicate that none of melanization origin, stage, space and variation type determining whether melanism will cause fitness gain or cost. PMID:26039886
The Capabilities and Applications of FY-3A/B SEM on Monitoring Space Weather Events
NASA Astrophysics Data System (ADS)
Huang, C.; Li, J.; Yu, T.; Xue, B.; Wang, C.; Zhang, X.; Cao, G.; Liu, D.; Tang, W.
2012-12-01
The Space Environment Monitor (SEM), on board the Chinese meteorological satellites, FengYun-3A/B has the abilities to measure proton flux in 3-300 Mev energy range and electron flux in 0.15-5.7 Mev energy range. SEM can also detect the heavy ion compositions, satellite surface potential, the radiation dose in sensors, and the single events. The space environment information derived from SEM can be utilized for satellite security designs, scientific studies, development of radiation belt models, and space weather monitoring and disaster warning. In this study, the SEM's instrument characteristics are introduced and the post-launch calibration algorithm is presented. The applications in monitoring space weather events and the service for manned spaceflights are also demonstrated.; The protons with particle energy over 10 Mev are called "killer particles". These particles may damage the satellite and cause disruption of satellite's system. The protons flux of 10 M-26 Mev energy band reached 5000 in the SPE caused by a solar flare with CME during the period of 2012.01.23 to 2012.01.27 as shown in the figure. THE COMPARISONS OF HEAVY IONS (2010.11.11-2010.12.15)t;
Yamashita, Taiji; Miyamoto, Kenji; Yonenobu, Hitoshi
2018-06-20
A new pretreatment method using room-temperature ionic liquid (IL) was proposed for observing wood specimens in scanning electron microscopy (SEM). A variety of concentrations were examined for ethanol solution of the IL, [Emim][MePO3Me], to determine an optimal pretreatment procedure. It was concluded that 10% ethanol solution of the IL was the most adequate to acquire good SEM images. Using the procedure optimized, SEM images were taken for typical anatomical types of modern soft and hardwood species and archeological wood. SEM images taken were sufficiently good in observing wood cells. The pretreatment method was also effective to archeological wood dated ca. 1600 years ago. It was thus concluded that the method developed in this study is more useful than those conventionally used. Additionally, pretreatment at the high temperature was performed to confirm morphological changes in softwood. Deformation of latewood cells (tracheids) was occurred by treating with undiluted IL at the high temperature of 50°C, probably due to higher accessibility of the IL into intercellular space. Nonetheless, it was confirmed that this happens under far more extreme conditions than our proposed method.
Yi, Feng; Stevanovic, Ana; Osborn, William A; Kolmakov, A; LaVan, David A
2017-11-01
We have developed a versatile nanocalorimeter sensor which allows imaging and electrical measurements of samples under different gaseous environments using the scanning electron microscope (SEM) and can simultaneously measure the sample temperature and associated heat of reaction. This new sensor consists of four independent heating/sensing elements for nanocalorimetry and eight electrodes for electrical measurements, all mounted on a 50 nm thick, 250 μm × 250 μm suspended silicon nitride membrane. This membrane is highly electron transparent and mechanically robust enabling in situ SEM observation under realistic temperatures, environmental conditions and pressures up to one atmosphere. To demonstrate this new capability, we report here on 1) in situ SEM-nanocalorimetry study of melting and solidification of polyethylene oxide, 2) the temperature dependence of conductivity of a nanowire; 3) the electron beam induced current measurements (EBID) of a nanowire in vacuum and air. Furthermore, the sensor is easily adaptable to operate in liquid environment and is compatible with most existing SEM. This versatile platform couples nanocalorimetry with in situ SEM imaging under various gaseous and liquid environments and is applicable to materials research, nanotechnology, energy, catalysis and biomedical applications.
The role of viable airborne microorganisms deposition in the southeastern Mediterranean Sea
NASA Astrophysics Data System (ADS)
Rahav, E.; Paytan, A.; Herut, B.
2016-02-01
Rahav Eyal1*, Paytan Adina2, Herut Barak1[1] Israel Oceanographic and Limnological Research, National Institute of Oceanography, Haifa 31080, Israel [2] Institute of Marine Science, University of California, Santa Cruz, CA, USA 95064. * Presenting author A high diversity of bacteria, fungi and virus are carried by atmospheric dust and deposit into the ocean. The oligotrophic southeastern Mediterranean Sea (SEMS) is known to receive relatively high amounts of atmospheric dust, thereby potentially be impacted by transport of air-borne microorganisms of diverse biogeographic origin. In this study, we characterized the genetic fingerprinting of microorganisms attached to dust in representative samples collected between 2006-2012 during storm events in the SEMS. Statistical analysis showed that dust of common origin was clustered together based on its genetic signature. Thus, microorganisms picked up in diverse geographical areas can interact differently with ambient populations. Further, microcosm dust addition experiments with surface SEMS filtered (0.2 µm) and killed (autoclaved) seawater showed that airborne microorganisms originated in dust collected in the SEMS significantly enhanced system's bacterial productivity, introduced new species and altered the abundance and activity of ambient surface microbial populations. Our results demonstrate that dust-borne microorganisms may play a significant role in the SEMS ecology.
SEM probe of IC radiation sensitivity
NASA Technical Reports Server (NTRS)
Gauthier, M. K.; Stanley, A. G.
1979-01-01
Scanning Electron Microscope (SEM) used to irradiate single integrated circuit (IC) subcomponent to test for radiation sensitivity can localize area of IC less than .03 by .03 mm for determination of exact location of radiation sensitive section.
2012-08-01
unlimited 3.1.2. Fractography Figure 5: SEM images of a 3.18mm thick sheet specimen tested at 760◦C/758MPa. (a) The region near the fracture surface... fractography using secondary electron imaging (SE) in a scanning electron microscope (SEM). No surface oxidation was observed at this temperature. The...ruptured after 210 hours. 3.2.3. Fractography The SEM image of the reconstructed creep ruptured specimen with thickness h = 3.18mm is shown in Fig. 18a
Detecção da fase impulsiva de uma explosão solar gigante até 405 GHz
NASA Astrophysics Data System (ADS)
Raulin, J.-P.; Makhmutov, V.; Kaufmann, P.; Pacini, A. A.; Luethi, T.; Hudson, H. S.; Gary, D. E.; Yoshimori, M.
2003-08-01
A explosão ocorrida no dia 25/08/2001 foi uma das mais intensas do presente ciclo solar em ondas de rádio de altas frequências. Foram medidas em ondas milimétricas e submilimétricas, aproximadamente, 105 e vários milhares de unidades de fluxo solar, respectivamente. Apresentamos um estudo deste evento em múltiplas frequências, desde microondas (1GHz), até ondas submilimétricas (405 GHz) detectadas pelo Telescópio Solar para ondas Submilimétricas (SST). Esta base de dados foi complementada utilizando-se o experimento Yohkoh, incluindo a emissão em raios-X duros e raios-g (até 100 MeV), e imagens em raios-X moles da região ativa envolvida. Enfocamos e discutimos principalmente os seguintes aspectos da fase impulsiva do evento: (i) as implicações deduzidas do espectro eletromagnético, obtido pela primeira vez até 405 GHz; (ii) a dinâmica da região ativa. Os resultados mostram que para explicar o espectro rádio observado, são necessários entre 3.5×1037 e 1.5×1039 elétrons acelerados acima de 20 keV em uma região de campo magnético entre 300 e 800 Gauss. A estimativa do fluxo de fótons que seria produzido por estes elétrons, mostra que grande parte deles não precipitou na baixa atmosfera. A evolução temporal da emissão em raios-X moles revela que a configuração magnética da região ativa foi muito dinâmica durante a fase impulsiva da explosão. Em particular, mostramos que a produção dos elétrons altamente energéticos foi iniciada junto com a aparição, na baixa coroa solar, de um novo sistema compacto de estruturas magnéticas. Este fato sugere que os locais de aceleração estão localizados na baixa atmosfera do Sol, como resultado da interação entre o novo sistema compacto e o campo magnético ambiente da região ativa.
A semantic proteomics dashboard (SemPoD) for data management in translational research.
Jayapandian, Catherine P; Zhao, Meng; Ewing, Rob M; Zhang, Guo-Qiang; Sahoo, Satya S
2012-01-01
One of the primary challenges in translational research data management is breaking down the barriers between the multiple data silos and the integration of 'omics data with clinical information to complete the cycle from the bench to the bedside. The role of contextual metadata, also called provenance information, is a key factor ineffective data integration, reproducibility of results, correct attribution of original source, and answering research queries involving "What", "Where", "When", "Which", "Who", "How", and "Why" (also known as the W7 model). But, at present there is limited or no effective approach to managing and leveraging provenance information for integrating data across studies or projects. Hence, there is an urgent need for a paradigm shift in creating a "provenance-aware" informatics platform to address this challenge. We introduce an ontology-driven, intuitive Semantic Proteomics Dashboard (SemPoD) that uses provenance together with domain information (semantic provenance) to enable researchers to query, compare, and correlate different types of data across multiple projects, and allow integration with legacy data to support their ongoing research. The SemPoD platform, currently in use at the Case Center for Proteomics and Bioinformatics (CPB), consists of three components: (a) Ontology-driven Visual Query Composer, (b) Result Explorer, and (c) Query Manager. Currently, SemPoD allows provenance-aware querying of 1153 mass-spectrometry experiments from 20 different projects. SemPod uses the systems molecular biology provenance ontology (SysPro) to support a dynamic query composition interface, which automatically updates the components of the query interface based on previous user selections and efficiently prunes the result set usinga "smart filtering" approach. The SysPro ontology re-uses terms from the PROV-ontology (PROV-O) being developed by the World Wide Web Consortium (W3C) provenance working group, the minimum information required for reporting a molecular interaction experiment (MIMIx), and the minimum information about a proteomics experiment (MIAPE) guidelines. The SemPoD was evaluated both in terms of user feedback and as scalability of the system. SemPoD is an intuitive and powerful provenance ontology-driven data access and query platform that uses the MIAPE and MIMIx metadata guideline to create an integrated view over large-scale systems molecular biology datasets. SemPoD leverages the SysPro ontology to create an intuitive dashboard for biologists to compose queries, explore the results, and use a query manager for storing queries for later use. SemPoD can be deployed over many existing database applications storing 'omics data, including, as illustrated here, the LabKey data-management system. The initial user feedback evaluating the usability and functionality of SemPoD has been very positive and it is being considered for wider deployment beyond the proteomics domain, and in other 'omics' centers.
Fairchild, J F; Kemble, N E; Allert, A L; Brumbaugh, W G; Ingersoll, C G; Dowling, B; Gruenenfelder, C; Roland, J L
2012-07-01
From 1930 to 1995, the Upper Columbia River (UCR) of northeast Washington State received approximately 12 million metric tons of smelter slag and associated effluents from a large smelter facility located in Trail, British Columbia, approximately 10 km north of the United States-Canadian border. Studies conducted during the past two decades have demonstrated the presence of toxic concentrations of heavy metals in slag-based sandy sediments, including cadmium, copper, zinc, and lead in the UCR area as well as the downstream reservoir portion of Lake Roosevelt. We conducted standardized whole-sediment toxicity tests with the amphipod Hyalella azteca (28-day) and the midge Chironomus dilutus (10-day) on 11 samples, including both UCR and study-specific reference sediments. Metal concentrations in sediments were modeled for potential toxicity using three approaches: (1) probable effects quotients (PEQs) based on total recoverable metals (TRMs) and simultaneously extracted metals (SEMs); (2) SEMs corrected for acid-volatile sulfides (AVS; i.e., ∑SEM - AVS); and (3) ∑SEM - AVS normalized to the fractional organic carbon (f(oc)) (i.e., ∑SEM - AVS/f(oc)). The most highly metal-contaminated sample (∑PEQ(TRM) = 132; ∑PEQ(SEM) = 54; ∑SEM - AVS = 323; and ∑SEM - AVS/(foc) = 64,600 umol/g) from the UCR was dominated by weathered slag sediment particles and resulted in 80% mortality and 94% decrease in biomass of amphipods; in addition, this sample significantly decreased growth of midge by 10%. The traditional ∑AVS - SEM, uncorrected for organic carbon, was the most accurate approach for estimating the effects of metals in the UCR. Treatment of the toxic slag sediment with 20% Resinex SIR-300 metal-chelating resin significantly decreased the toxicity of the sample. Samples ∑SEM - AVS > 244 was not toxic to amphipods or midge in laboratory testing, indicating that this value may be an approximate threshold for effects in the UCR. In situ benthic invertebrate colonization studies in an experimental pond (8-week duration) indicated that two of the most metal-contaminated UCR sediments (dominated by high levels of sand-sized slag particles) exhibited decreased invertebrate colonization compared with sand-based reference sediments. Field-exposed SIR-300 resin samples also exhibited decreased invertebrate colonization numbers compared with reference materials, which may indicate behavioral avoidance of this material under field conditions. Multiple lines of evidence (analytical chemistry, laboratory toxicity, and field colonization results), along with findings from previous studies, indicate that high metal concentrations associated with slag-enriched sediments in the UCR are likely to adversely impact the growth and survival of native benthic invertebrate communities. Additional laboratory toxicity testing, refinement of the applications of sediment benchmarks for metal toxicity, and in situ benthic invertebrate studies will assist in better defining the spatial extent, temporal variations, and ecological impacts of metal-contaminated sediments in the UCR system.
2014-01-01
Background A balance test provides important information such as the standard to judge an individual’s functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Methods Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). Results The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. Conclusion The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment. PMID:24912769
Park, Dae-Sung; Lee, GyuChang
2014-06-10
A balance test provides important information such as the standard to judge an individual's functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment.
Ogendi, G.M.; Brumbaugh, W.G.; Hannigan, R.E.; Farris, J.L.
2007-01-01
Metal bioavailability and toxicity to aquatic organisms are greatly affected by variables such as pH, hardness, organic matter, and sediment acid-volatile sulfide (AVS). Sediment AVS, which reduces metal bioavailability and toxicity by binding and immobilizing metals as insoluble sulfides, has been studied intensely in recent years. Few studies, however, have determined the spatial variability of AVS and its interaction with simultaneously extracted metals (SEM) in sediments containing elevated concentrations of metals resulting from natural geochemical processes, such as weathering of black shales. We collected four sediment samples from each of four headwater bedrock streams in northcentral Arkansa (USA; three black shale-draining streams and one limestone-draining stream). We conducted 10-d acute whole-sediment toxicity tests using the midge Chironomus tentans and performed analyses for AVS, total metals, SEMs, and organic carbon. Most of the sediments from shale-draining streams had similar total metal and SEM concentrations but considerable differences in organic carbon and AVS. Zinc was the leading contributor to the SEM molar sum, averaging between 68 and 74%, whereas lead and cadmium contributed less than 3%. The AVS concentration was very low in all but two samples from one of the shale streams, and the sum of the SEM concentrations was in molar excess of AVS for all shale stream sediments. No significant differences in mean AVS concentrations between sediments collected from shale-draining or limestone-draining sites were noted (p > 0.05). Midge survival and growth in black shale-derived sediments were significantly less (p < 0.001) than that of limestone-derived sediments. On the whole, either SEM alone or SEM-AVS explained the total variation in midge survival and growth about equally well. However, survival and growth were significantly greater (p < 0.05) in the two sediment samples that contained measurable AVS compared with the two sediments from the same stream that contained negligible AVS. ?? 2007 SETAC.
Chaves, Dalton Marques; Mönkemüller, Klaus; Carneiro, Fred; Medrado, Bruno; Dos Santos, Marcos; Wodak, Stephanie; Reimão, Sílvia; Sakai, Paulo; de Moura, Eduardo
2014-12-01
Background/study aim: During the last several years, endoscopic ultrasound (EUS)-guided pancreatic fluid collections' (PFC) drainage has evolved into the preferred drainage technique. Recently, self-expanding metallic stents (SEMS) have been used as an alternative to double pigtail stents, with the advantage of providing a larger diameter fistula, thereby decreasing the risk of early obstruction and also allowing for direct endoscopic exploration of the cavity. The aim of this study was to evaluate the technical and clinical success, safety, and outcome of patients undergoing EUS-guided drainage of complex PFC using SEMS. The study was conducted at two tertiary hospitals from January 2010 to January 2013. All patients with PFC referred for endoscopic drainage were enrolled in a prospective database. The inclusion criteria were: (1) patients with pseudocysts or walled-off necrosis based on the revised Atlanta classification; (2) symptomatic patients with thick PFC; (3) PFC that persisted more than 6 weeks; and (4) large PFC diameter (≥ 9 cm). The exclusion criteria consisted of coagulation disorders, PFC bleeding or infection, and failure-to-inform written consent. A total of 16 patients (9 females, 7 males; mean age 52.6, range 20 - 82) underwent EUS drainage with SEMS. There were 14 cases of pseudocysts and 2 cases of walled-off necrosis. The etiologies of the PFC were mainly gallstones (8 of 16 patients, 50 %) and alcohol (5 of 16 patients, 31 %). Technical success was achieved in 100 % of the cases. All patients had a complete resolution of the PFC. Transmural EUS-guided drainage of complex PFC using SEMS is feasible, appears safe, and is efficacious. However, the exchange of the UC (uncovered)-SEMS for plastic stents is mandatory within 1 week. Future prospective studies, preferably multicenter studies, comparing SEMS versus traditional plastic stents for the drainage of PFC are warranted.
Thackeray, J F; Dykes, S
2016-02-01
Thackeray has previously explored the possibility of using a morphometric approach to quantify the "amount" of variation within species and to assess probabilities of conspecificity when two fossil specimens are compared, instead of "pigeon-holing" them into discrete species. In an attempt to obtain a statistical (probabilistic) definition of a species, Thackeray has recognized an approximation of a biological species constant (T=-1.61) based on the log-transformed standard error of the coefficient m (log sem) in regression analysis of cranial and other data from pairs of specimens of conspecific extant species, associated with regression equations of the form y=mx+c where m is the slope and c is the intercept, using measurements of any specimen A (x axis), and any specimen B of the same species (y axis). The log-transformed standard error of the co-efficient m (log sem) is a measure of the degree of similarity between pairs of specimens, and in this study shows central tendency around a mean value of -1.61 and standard deviation 0.10 for modern conspecific specimens. In this paper we focus attention on the need to take into account the range of difference in log sem values (Δlog sem or "delta log sem") obtained from comparisons when specimen A (x axis) is compared to B (y axis), and secondly when specimen A (y axis) is compared to B (x axis). Thackeray's approach can be refined to focus on high probabilities of conspecificity for pairs of specimens for which log sem is less than -1.61 and for which Δlog sem is less than 0.03. We appeal for the adoption of a concept here called "sigma taxonomy" (as opposed to "alpha taxonomy"), recognizing that boundaries between species are not always well defined. Copyright © 2015 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Kaboli, S.; Burnley, P. C.
2017-12-01
Imaging and characterization of defects in crystalline materials is of significant importance in various disciplines including geoscience, materials science, and applied physics. Linear defects such as dislocations and planar defects such as twins and stacking faults, strongly influence many of the properties of crystalline materials and also reflect the conditions and degree of deformation. Dislocations have been conventionally imaged in thin foils in a transmission electron microscope (TEM). Since the development of field emission scanning electron microscopes (FE-SEM) with high gun brightness and small spot size, extensive efforts have been dedicated to the imaging and characterization of dislocations in semi-conductors using electron channeling contrast imaging (ECCI) in the SEM. The obvious advantages of using SEM over TEM include easier and non-destructive sample preparation and a large field of view enabling statistical examination of the density and distribution of dislocations and other defects. In this contribution, we extend this technique to geological materials and introduce the Real Space Crystallography methodology for imaging and complete characterization of dislocations based on bend contour contrast obtained by ECCI in FE-SEM. Bend contours map out the distortion in the crystal lattice across a deformed grain. The contrast of dislocations is maximum in the vicinity of bend contours where crystal planes diffract at small and positive deviations from the Bragg positions (as defined by Bragg's law of electron diffraction). Imaging is performed in a commercial FE-SEM equipped with a standard silicon photodiode backscattered (BSE) detector and an electron backscatter diffraction (EBSD) system for crystal orientation measurements. We demonstrate the practice of this technique in characterization of a number of geological materials in particular quartz, forsterite olivine and corundum, experimentally deformed at high pressure-temperature conditions. This new approach in microstructure characterization of deformed geologic materials in FE-SEM, without the use of etching or decoration techniques, has valuable applications to both experimentally deformed and naturally deformed specimens.
SEM based overlay measurement between resist and buried patterns
NASA Astrophysics Data System (ADS)
Inoue, Osamu; Okagawa, Yutaka; Hasumi, Kazuhisa; Shao, Chuanyu; Leray, Philippe; Lorusso, Gian; Baudemprez, Bart
2016-03-01
With the continuous shrink in pattern size and increased density, overlay control has become one of the most critical issues in semiconductor manufacturing. Recently, SEM based overlay of AEI (After Etch Inspection) wafer has been used for reference and optimization of optical overlay (both Image Based Overlay (IBO) and Diffraction Based Overlay (DBO)). Overlay measurement at AEI stage contributes monitor and forecast the yield after formation by etch and calibrate optical measurement tools. however those overlay value seems difficult directly for feedback to a scanner. Therefore, there is a clear need to have SEM based overlay measurements of ADI (After Develop Inspection) wafers in order to serve as reference for optical overlay and make necessary corrections before wafers go to etch. Furthermore, to make the corrections as accurate as possible, actual device like feature dimensions need to be measured post ADI. This device size measurement is very unique feature of CDSEM , which can be measured with smaller area. This is currently possible only with the CD-SEM. This device size measurement is very unique feature of CD-SEM , which can be measured with smaller area. In this study, we assess SEM based overlay measurement of ADI and AEI wafer by using a sample from an N10 process flow. First, we demonstrate SEM based overlay performance at AEI by using dual damascene process for Via 0 (V0) and metal 1 (M1) layer. We also discuss the overlay measurements between litho-etch-litho stages of a triple patterned M1 layer and double pattern V0. Second, to illustrate the complexities in image acquisition and measurement we will measure overlay between M1B resist and buried M1A-Hard mask trench. Finally, we will show how high accelerating voltage can detect buried pattern information by BSE (Back Scattering Electron). In this paper we discuss the merits of this method versus standard optical metrology based corrections.
Using structural equation modeling for network meta-analysis.
Tu, Yu-Kang; Wu, Yun-Chun
2017-07-14
Network meta-analysis overcomes the limitations of traditional pair-wise meta-analysis by incorporating all available evidence into a general statistical framework for simultaneous comparisons of several treatments. Currently, network meta-analyses are undertaken either within the Bayesian hierarchical linear models or frequentist generalized linear mixed models. Structural equation modeling (SEM) is a statistical method originally developed for modeling causal relations among observed and latent variables. As random effect is explicitly modeled as a latent variable in SEM, it is very flexible for analysts to specify complex random effect structure and to make linear and nonlinear constraints on parameters. The aim of this article is to show how to undertake a network meta-analysis within the statistical framework of SEM. We used an example dataset to demonstrate the standard fixed and random effect network meta-analysis models can be easily implemented in SEM. It contains results of 26 studies that directly compared three treatment groups A, B and C for prevention of first bleeding in patients with liver cirrhosis. We also showed that a new approach to network meta-analysis based on the technique of unrestricted weighted least squares (UWLS) method can also be undertaken using SEM. For both the fixed and random effect network meta-analysis, SEM yielded similar coefficients and confidence intervals to those reported in the previous literature. The point estimates of two UWLS models were identical to those in the fixed effect model but the confidence intervals were greater. This is consistent with results from the traditional pairwise meta-analyses. Comparing to UWLS model with common variance adjusted factor, UWLS model with unique variance adjusted factor has greater confidence intervals when the heterogeneity was larger in the pairwise comparison. The UWLS model with unique variance adjusted factor reflects the difference in heterogeneity within each comparison. SEM provides a very flexible framework for univariate and multivariate meta-analysis, and its potential as a powerful tool for advanced meta-analysis is still to be explored.
Hald, Gert Martin; Smolenski, Derek; Simon Rosser, B. R.
2012-01-01
Introduction Researchers have proposed that consumption of Sexually Explicit Media (SEM) may not only adversely influence sexual attitudes and behaviors of Men Who Have Sex with Men (MSM) but (also) play a positive role in the development and sexual education of MSM, be a major source of sexual information for MSM, and provide validation, understanding, and confirmation of MSM’s sexual orientation. However, such claims are in urgent need of empirical validation as is the development of psychometrically sound and easily implemented instruments able to reliably assist such validations. Aim To investigate how MSM who consume SEM self-perceive the impact of SEM on their STI-related sexual risk behaviors (i.e. anal intercourse), sexual knowledge, enjoyment of sex, interest in sex, attitudes toward sex, and understanding of their sexual orientation. Further, to provide a thorough psychometric validation of a reduced and reworked version of the Pornography Consumption Effect Scale. Main Outcomes Measures A revised version of the Pornography Consumption Effect Scale (PCES) by Hald and Malamuth (2008). Results This study found that 97% of MSM reported positive effects of SEM consumption on their sexual knowledge, enjoyment of and interest in sex, attitudes toward sex, and understanding of their sexual orientation. Only 3 % reported any negative effects of their SEM consumption. SEM consumption was found to significantly increase consumers’ interest in having protected anal intercourse while not significantly influencing their interests in having unprotected anal intercourse. The revised version of the PCES showed excellent psychometric performance. Conclusion The study found that MSM generally report positive effects of their consumption of sexually explicit materials in areas related to their sexual knowledge, attitudes, behaviors, and orientation. This finding could have important implications for the sexual health and well-being of MSM by suggesting that SEM-based education and intervention might hold considerable overall health potential for MSM. PMID:23110358
Imaging of surface spin textures on bulk crystals by scanning electron microscopy
NASA Astrophysics Data System (ADS)
Akamine, Hiroshi; Okumura, So; Farjami, Sahar; Murakami, Yasukazu; Nishida, Minoru
2016-11-01
Direct observation of magnetic microstructures is vital for advancing spintronics and other technologies. Here we report a method for imaging surface domain structures on bulk samples by scanning electron microscopy (SEM). Complex magnetic domains, referred to as the maze state in CoPt/FePt alloys, were observed at a spatial resolution of less than 100 nm by using an in-lens annular detector. The method allows for imaging almost all the domain walls in the mazy structure, whereas the visualisation of the domain walls with the classical SEM method was limited. Our method provides a simple way to analyse surface domain structures in the bulk state that can be used in combination with SEM functions such as orientation or composition analysis. Thus, the method extends applications of SEM-based magnetic imaging, and is promising for resolving various problems at the forefront of fields including physics, magnetics, materials science, engineering, and chemistry.
A versatile atomic force microscope integrated with a scanning electron microscope.
Kreith, J; Strunz, T; Fantner, E J; Fantner, G E; Cordill, M J
2017-05-01
A versatile atomic force microscope (AFM), which can be installed in a scanning electron microscope (SEM), is introduced. The flexible design of the instrument enables correlated analysis for different experimental configurations, such as AFM imaging directly after nanoindentation in vacuum. In order to demonstrate the capabilities of the specially designed AFM installed inside a SEM, slip steps emanating around nanoindents in single crystalline brass were examined. This example showcases how the combination of AFM and SEM imaging can be utilized for quantitative dislocation analysis through the measurement of the slip step heights without the hindrance of oxide formation. Finally, an in situ nanoindentation technique is introduced, illustrating the use of AFM imaging during indentation experiments to examine plastic deformation occurring under the indenter tip. The mechanical indentation data are correlated to the SEM and AFM images to estimate the number of dislocations emitted to the surface.
Enhanced EDX images by fusion of multimodal SEM images using pansharpening techniques.
Franchi, G; Angulo, J; Moreaud, M; Sorbier, L
2018-01-01
The goal of this paper is to explore the potential interest of image fusion in the context of multimodal scanning electron microscope (SEM) imaging. In particular, we aim at merging the backscattered electron images that usually have a high spatial resolution but do not provide enough discriminative information to physically classify the nature of the sample, with energy-dispersive X-ray spectroscopy (EDX) images that have discriminative information but a lower spatial resolution. The produced images are named enhanced EDX. To achieve this goal, we have compared the results obtained with classical pansharpening techniques for image fusion with an original approach tailored for multimodal SEM fusion of information. Quantitative assessment is obtained by means of two SEM images and a simulated dataset produced by a software based on PENELOPE. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.
Structural equation modeling: building and evaluating causal models: Chapter 8
Grace, James B.; Scheiner, Samuel M.; Schoolmaster, Donald R.
2015-01-01
Scientists frequently wish to study hypotheses about causal relationships, rather than just statistical associations. This chapter addresses the question of how scientists might approach this ambitious task. Here we describe structural equation modeling (SEM), a general modeling framework for the study of causal hypotheses. Our goals are to (a) concisely describe the methodology, (b) illustrate its utility for investigating ecological systems, and (c) provide guidance for its application. Throughout our presentation, we rely on a study of the effects of human activities on wetland ecosystems to make our description of methodology more tangible. We begin by presenting the fundamental principles of SEM, including both its distinguishing characteristics and the requirements for modeling hypotheses about causal networks. We then illustrate SEM procedures and offer guidelines for conducting SEM analyses. Our focus in this presentation is on basic modeling objectives and core techniques. Pointers to additional modeling options are also given.
NASA Astrophysics Data System (ADS)
Kareiva, Simonas; Klimavicius, Vytautas; Momot, Aleksandr; Kausteklis, Jonas; Prichodko, Aleksandra; Dagys, Laurynas; Ivanauskas, Feliksas; Sakirzanovas, Simas; Balevicius, Vytautas; Kareiva, Aivaras
2016-09-01
Aqueous sol-gel chemistry route based on ammonium-hydrogen phosphate as the phosphorus precursor, calcium acetate monohydrate as source of calcium ions, and 1,2-ethylendiaminetetraacetic acid (EDTA), or 1,2-diaminocyclohexanetetracetic acid (DCTA), or tartaric acid (TA), or ethylene glycol (EG), or glycerol (GL) as complexing agents have been used to prepare calcium hydroxyapatite (Ca10(PO4)6(OH)2, CHAp). The phase transformations, composition, and structural changes in the polycrystalline samples were studied by infrared spectroscopy (FTIR), X-ray powder diffraction analysis (XRD), and scanning electron microscopy (SEM). The local short-range (nano- and mezo-) scale effects in CHAp were studied using solid-state NMR spectroscopy. The spatial 3D data from the SEM images of CHAp samples obtained by TA, EG and GL sol-gel routes were recovered for the first time to our knowledge.
Mechanical Sensing with Flexible Metallic Nanowires
NASA Astrophysics Data System (ADS)
Dobrokhotov, Vladimir; Yazdanpanah, Mehdi; Pabba, Santosh; Safir, Abdelilah; Cohn, Robert
2008-03-01
A calibrated method of force sensing is demonstrated in which the buckled shape of a long flexible metallic nanowire is interpreted to determine the applied force. Using a nanomanipulator the nanowire is buckled in the chamber of a scanning electron microscope (SEM) and the buckled shapes are recorded in SEM images. Force is determined as a function of deflection for an assumed elastic modulus by fitting the shapes using the generalized elastica model. In this calibration the elastic modulus was determined using an auxiliary AFM measurement, with the needle in the same orientation as in the SEM. Following this calibration the needle was used as a sensor in a different orientation than the AFM coordinates to deflect a suspended PLLA polymer fiber from which the elastic modulus (2.96 GPa) was determined. In this study the same needle remained rigidly secured to the AFM cantilever throughout the entire SEM/AFM calibration procedure and the characterization of the nanofiber.
Enhanced FIB-SEM systems for large-volume 3D imaging.
Xu, C Shan; Hayworth, Kenneth J; Lu, Zhiyuan; Grob, Patricia; Hassan, Ahmed M; García-Cerdán, José G; Niyogi, Krishna K; Nogales, Eva; Weinberg, Richard J; Hess, Harald F
2017-05-13
Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 µm 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.
X-ray microscopy using reflection targets based on SEM with tungsten filament
NASA Astrophysics Data System (ADS)
Liu, Junbiao; Ma, Yutian; Zhao, Weixia; Niu, Geng; Chu, Mingzhang; Yin, Bohua; Han, Li; Liu, Baodong
2016-10-01
X-ray MicroandNano imaging is developed based on the conventional x-ray tomography, it can not only provide nondestructive testing with higher resolution measurement, but also be used to examine the material or the structure with low atomic number and low density. The source with micro-focal spot size is one of the key components of x-ray MicroandNano imaging. The focused electron beam from SEM bombarding the metal target can generate x-ray with ultra-small size. It is convenient to set up x-ray microscopy based on SEM for laboratory use. This paper describes a new x-ray microscopy using reflection targets based on FEI Quanta600 SEM with tungsten filament. The flat panel detector is placed outside of the vacuum chamber with 300μm thickness Be-window to isolate vacuum from the air. A stage with 3 DOFs is added to adjust the positions of the target, the SEM's sample stage is used to move sample. And the shape of target is designed as cone with 60° half cone angle to get the maximum x-ray dosage. The attenuation coefficient of Bewindow for x-ray is about 25%. Finally, the line pair card is used to evaluate the resolution and the result shows that the resolution of the system can receive less than 750nm, when the acceleration voltage is 30keV, the beam current is 160nA, the SEM working distance is 5mm and the acquisition time of the detector is 60s.
Kiani, M A; Sim, K S; Nia, M E; Tso, C P
2015-05-01
A new technique based on cubic spline interpolation with Savitzky-Golay smoothing using weighted least squares error filter is enhanced for scanning electron microscope (SEM) images. A diversity of sample images is captured and the performance is found to be better when compared with the moving average and the standard median filters, with respect to eliminating noise. This technique can be implemented efficiently on real-time SEM images, with all mandatory data for processing obtained from a single image. Noise in images, and particularly in SEM images, are undesirable. A new noise reduction technique, based on cubic spline interpolation with Savitzky-Golay and weighted least squares error method, is developed. We apply the combined technique to single image signal-to-noise ratio estimation and noise reduction for SEM imaging system. This autocorrelation-based technique requires image details to be correlated over a few pixels, whereas the noise is assumed to be uncorrelated from pixel to pixel. The noise component is derived from the difference between the image autocorrelation at zero offset, and the estimation of the corresponding original autocorrelation. In the few test cases involving different images, the efficiency of the developed noise reduction filter is proved to be significantly better than those obtained from the other methods. Noise can be reduced efficiently with appropriate choice of scan rate from real-time SEM images, without generating corruption or increasing scanning time. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
The detection of metallic residues in skin stab wounds by means of SEM-EDS: A pilot study.
Palazzo, Elisa; Amadasi, Alberto; Boracchi, Michele; Gentile, Guendalina; Maciocco, Francesca; Marchesi, Matteo; Zoja, Riccardo
2018-05-01
The morphological analysis of stab wounds may often not be accurate enough to link it with the type of wounding weapon, but a further evaluation may be performed with the search for metallic residues left during the contact between the instrument and the skin. In this study, Scanning Electron Microscopy-Energy Dispersive Spectroscopy (SEM-EDS) was applied to the study of cadaveric stab wounds performed with kitchen knives composed of iron, chromium and nickel, in order to verify the presence of metallic residues on the wound's edge. Two groups of 10 corpses were selected: group A, including victims of stab wounds and a control group B (died of natural causes). Samplings were performed on the lesions and in intact areas of group A, whereas in group B sampling were performed in non-exposed intact skin. Samples were then analysed with optical microscopy and SEM-EDS. In group A, optical microscopic analysis showed the presence of vital haemorrhagic infiltration, while SEM-EDS showed evidence of microscopic metal traces, isolated or clustered, consisting of iron, chromium and nickel. Moreover, in two cases organic residues of calcium and phosphate were detected, as a probable sign of bone lesion. Control samples (group A in intact areas and group B), were negative for the search of exogenous material to optical microscopy and SEM-EDS. The results show the utility and possible application of the SEM-EDS in theidentification of metallic residues from sharp weapons on the skin. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.
Surgery on spinal epidural metastases (SEM) in renal cell carcinoma: a plea for a new paradigm.
Bakker, Nicolaas A; Coppes, Maarten H; Vergeer, Rob A; Kuijlen, Jos M A; Groen, Rob J M
2014-09-01
Prediction models for outcome of decompressive surgical resection of spinal epidural metastases (SEM) have in common that they have been developed for all types of SEM, irrespective of the type of primary tumor. It is our experience in clinical practice, however, that these models often fail to accurately predict outcome in the individual patient. To investigate whether decision making could be optimized by applying tumor-specific prediction models. For the proof of concept, we analyzed patients with SEM from renal cell carcinoma that we have operated on. Retrospective chart analysis 2006 to 2012. Twenty-one consecutive patients with symptomatic SEM of renal cell carcinoma. Predictive factors for survival. Next to established predictive factors for survival, we analyzed the predictive value of the Motzer criteria in these patients. The Motzer criteria comprise a specific and validated risk model for survival in patients with renal cell carcinoma. After multivariable analysis, only Motzer intermediate (hazard ratio [HR] 17.4, 95% confidence interval [CI] 1.82-166, p=.01) and high risk (HR 39.3, 95% CI 3.10-499, p=.005) turned out to be significantly associated with survival in patients with renal cell carcinoma that we have operated on. In this study, we have demonstrated that decision making could have been optimized by implementing the Motzer criteria next to established prediction models. We, therefore, suggest that in future, in patients with SEM from renal cell carcinoma, the Motzer criteria are also taken into account. Copyright © 2014 Elsevier Inc. All rights reserved.
The potential health benefits of legumes as a good source of dietary fibre.
Trinidad, Trinidad P; Mallillin, Aida C; Loyola, Anacleta S; Sagum, Rosario S; Encabo, Rosario R
2010-02-01
Dietary fibre has been shown to have important health implications in the prevention of risks of chronic diseases. The objective of the present study was to determine the potential health benefits of legumes as a good source of dietary fibre. Six to ten local legumes were studied as follows: cowpeas, mung beans, pole sitao, chickpeas, green peas, groundnuts, pigeon peas, kidney beans, lima beans and soyabeans. The following studies were conducted: (a) mineral availability, in vitro; (b) glycaemic index (GI) in non-diabetic and diabetic human subjects; (c) the cholesterol-lowering effect in human subjects with moderately raised serum cholesterol levels. The highest Fe availability among legumes was for lima beans (9.5 (sem 0.1)) while for Zn and Ca, the highest availability was for kidney beans (49.3 (sem 4.5)) and pigeon peas (75.1 (sem 7.1)), respectively. Groundnuts have the lowest Fe (1.3 (sem 1.1)), Zn (7.9 (sem 1.3)) and Ca (14.6 (sem 2.8)) availability. Legumes are low-GI foods ( < 55), ranging from 6 (chickpeas) to 13 (mung beans). Kidney beans showed significant reductions for both total (6 %) and LDL-cholesterol (9 %), and groundnuts for total cholesterol (7 %; P < 0.05). We conclude that mineral availability from legumes differs and may be attributed to their mineral content, mineral-mineral interaction and from their phytic and tannic acid content; legumes are considered low-GI foods and have shown potential hypocholesterolaemic effects. The above studies can be a scientific basis for considering legumes as functional foods.
Learmonth, Yvonne C; Dlugonski, Deirdre D; Pilutti, Lara A; Sandroff, Brian M; Motl, Robert W
2013-11-01
Assessing walking impairment in those with multiple sclerosis (MS) is common, however little is known about the reliability, precision and clinically important change of walking outcomes. The purpose of this study was to determine the reliability, precision and clinically important change of the Timed 25-Foot Walk (T25FW), Six-Minute Walk (6MW), Multiple Sclerosis Walking Scale-12 (MSWS-12) and accelerometry. Data were collected from 82 persons with MS at two time points, six months apart. Analyses were undertaken for the whole sample and stratified based on disability level and usage of walking aids. Intraclass correlation coefficient (ICC) analyses established reliability: standard error of measurement (SEM) and coefficient of variation (CV) determined precision; and minimal detectable change (MDC) defined clinically important change. All outcome measures were reliable with precision and MDC varying between measures in the whole sample: T25FW: ICC=0.991; SEM=1 s; CV=6.2%; MDC=2.7 s (36%), 6MW: ICC=0.959; SEM=32 m; CV=6.2%; MDC=88 m (20%), MSWS-12: ICC=0.927; SEM=8; CV=27%; MDC=22 (53%), accelerometry counts/day: ICC=0.883; SEM=28450; CV=17%; MDC=78860 (52%), accelerometry steps/day: ICC=0.907; SEM=726; CV=16%; MDC=2011 (45%). Variation in these estimates was seen based on disability level and walking aid. The reliability of these outcomes is good and falls within acceptable ranges. Precision and clinically important change estimates provide guidelines for interpreting these outcomes in clinical and research settings.
Barkun, Alan N; Adam, Viviane; Martel, Myriam; AlNaamani, Khalid; Moses, Peter L
2015-01-01
BACKGROUND/OBJECTIVE: Partially covered self-expandable metal stents (SEMS) and polyethylene stents (PES) are both commonly used in the palliation of malignant biliary obstruction. Although SEMS are significantly more expensive, they are more efficacious than PES. Accordingly, a cost-effectiveness analysis was performed. METHODS: A cost-effectiveness analysis compared the approach of initial placement of PES versus SEMS for the study population. Patients with malignant biliary obstruction underwent an endoscopic retrograde cholangiopancreatography to insert the initial stent. If the insertion failed, a percutaneous transhepatic cholangiogram was performed. If stent occlusion occurred, a PES was inserted at repeat endoscopic retrograde cholangiopancreatography, either in an outpatient setting or after admission to hospital if cholangitis was present. A third-party payer perspective was adopted. Effectiveness was expressed as the likelihood of no occlusion over the one-year adopted time horizon. Probabilities were based on a contemporary randomized clinical trial, and costs were issued from national references. Deterministic and probabilistic sensitivity analyses were performed. RESULTS: A PES-first strategy was both more expensive and less efficacious than an SEMS-first approach. The mean per-patient costs were US$6,701 for initial SEMS and US$20,671 for initial PES, which were associated with effectiveness probabilities of 65.6% and 13.9%, respectively. Sensitivity analyses confirmed the robustness of these results. CONCLUSION: At the time of initial endoscopic drainage for patients with malignant biliary obstruction undergoing palliative stenting, an initial SEMS insertion approach was both more effective and less costly than a PES-first strategy. PMID:26125107
Merchán-Pérez, Angel; Rodriguez, José-Rodrigo; Alonso-Nanclares, Lidia; Schertel, Andreas; Defelipe, Javier
2009-01-01
The advent of transmission electron microscopy (TEM) in the 1950s represented a fundamental step in the study of neuronal circuits. The application of this technique soon led to the realization that the number of synapses changes during the course of normal life, as well as under certain pathological or experimental circumstances. Since then, one of the main goals in neurosciences has been to define simple and accurate methods to estimate the magnitude of these changes. Contrary to analysing single sections, TEM reconstructions are extremely time-consuming and difficult. Therefore, most quantitative studies use stereological methods to define the three-dimensional characteristics of synaptic junctions that are studied in two dimensions. Here, to count the exact number of synapses per unit of volume we have applied a new three-dimensional reconstruction method that involves the combination of focused ion beam milling and scanning electron microscopy (FIB/SEM). We show that the images obtained with FIB/SEM are similar to those obtained with TEM, but with the advantage that FIB/SEM permits serial reconstructions of large volumes of tissue to be generated rapidly and automatically. Furthermore, we compared the estimates of the number of synapses obtained with stereological methods with the values obtained by FIB/SEM reconstructions. We concluded that FIB/SEM not only provides the actual number of synapses per volume but it is also much easier and faster to use than other currently available TEM methods. More importantly, it also avoids most of the errors introduced by stereological methods and overcomes the difficulties associated with these techniques.
Spatially explicit modeling in ecology: A review
DeAngelis, Donald L.; Yurek, Simeon
2017-01-01
The use of spatially explicit models (SEMs) in ecology has grown enormously in the past two decades. One major advancement has been that fine-scale details of landscapes, and of spatially dependent biological processes, such as dispersal and invasion, can now be simulated with great precision, due to improvements in computer technology. Many areas of modeling have shifted toward a focus on capturing these fine-scale details, to improve mechanistic understanding of ecosystems. However, spatially implicit models (SIMs) have played a dominant role in ecology, and arguments have been made that SIMs, which account for the effects of space without specifying spatial positions, have an advantage of being simpler and more broadly applicable, perhaps contributing more to understanding. We address this debate by comparing SEMs and SIMs in examples from the past few decades of modeling research. We argue that, although SIMs have been the dominant approach in the incorporation of space in theoretical ecology, SEMs have unique advantages for addressing pragmatic questions concerning species populations or communities in specific places, because local conditions, such as spatial heterogeneities, organism behaviors, and other contingencies, produce dynamics and patterns that usually cannot be incorporated into simpler SIMs. SEMs are also able to describe mechanisms at the local scale that can create amplifying positive feedbacks at that scale, creating emergent patterns at larger scales, and therefore are important to basic ecological theory. We review the use of SEMs at the level of populations, interacting populations, food webs, and ecosystems and argue that SEMs are not only essential in pragmatic issues, but must play a role in the understanding of causal relationships on landscapes.
Inoue, Tadahisa; Ishii, Norimitsu; Kobayashi, Yuji; Kitano, Rena; Sakamoto, Kazumasa; Ohashi, Tomohiko; Nakade, Yukiomi; Sumida, Yoshio; Ito, Kiyoaki; Nakao, Haruhisa; Yoneda, Masashi
2017-09-01
Endoscopic bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstructions (MHBOs) is technically demanding, and a second SEMS insertion is particularly challenging. A simultaneous side-by-side (SBS) placement technique using a thinner delivery system may mitigate these issues. We aimed to examine the feasibility and efficacy of simultaneous SBS SEMS placement for treating MHBOs using a novel SEMS that has a 5.7-Fr ultra-thin delivery system. Thirty-four patients with MHBOs underwent SBS SEMS placement between 2010 and 2016. We divided the patient cohort into those who underwent sequential (conventional) SBS placement between 2010 and 2014 (sequential group) and those who underwent simultaneous SBS placement between 2015 and 2016 (simultaneous group), and compared the groups with respect to the clinical outcomes. The technical success rates were 71% (12/17) and 100% (17/17) in the sequential and simultaneous groups, respectively, a difference that was significant (P = .045). The median procedure time was significantly shorter in the simultaneous group (22 min) than in the sequential group (52 min) (P = .017). There were no significant group differences in the time to recurrent biliary obstruction (sequential group: 113 days; simultaneous group: 140 days) or other adverse event rates (sequential group: 12%; simultaneous group: 12%). Simultaneous SBS placement using the novel 5.7-Fr SEMS delivery system may be more straightforward and have a higher success rate compared to that with sequential SBS placement. This new method may be useful for bilateral stenting to treat MHBOs.
Bioavailability of seleno-compounds in the lactating rat
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, A.M.; Picciano, M.F.
Previously the authors reported an increased selenium (Se) requirement for lactating rats of at least 0.2 ppm dietary Se if provided as selenite (SEL). In the present study bioavailability of selenomethionine (SEM), Se yeast (SEY) and SEL was assessed. A casein-based diet (0.025 ppm Se) was fed to 9 groups of 8 rats each during pregnancy to produce a marginal Se deficiency. During lactation each group was fed the same diet containing either 0.1, 0.25, or 0.5 ppm Se as SEL, SEM, or SEY. On day 18 of lactation dams and pups were sacrificed and tissue Se and glutathione peroxidasemore » activities (GPx) determined. Although food intake of the dams and growth of the pups did not vary, selenium and GPx activities were dependent upon quantity and form of Se consumed. Using slope-ratio analysis linear increases in blood, tissue and milk Se content the bioavailabilities were SEM>SEY>SEL. Maximal GPx depended on the form of dietary Se with SEM>SEY>SEL. Maximal GPx occurred at 0.25 ppm dietary Se as SEM and SEY, but did not reach this activity when fed at 0.5 ppm Se as SEL. These results indicate that regardless of form, the NRC requirement for growing rats of 0.1 ppm Se, is not adequate during lactation to maintain maximum tissue GSH-Px in nursing pups. Based on higher tissue Se in dams and GPx in nursing pups the bioavailability of dietary Se to the lactating rat is greater when fed as SEM and SEY than as SEL.« less
Siddiqui, Ali; Shahid, Haroon; Sarkar, Avik; Cox, Kristen; Kowalski, Thomas E; Loren, David E; Sharma, Ashish; Laing, Patrick; Birch, Madeline; Adler, Douglas G
2013-09-01
Most patients with hilar cholangiocarcinomas present with unresectable tumors, so only palliative biliary drainage with self-expanding metal stents (SEMS) is possible. Stents eventually cease to function because of tumor overgrowth and/or other causes, so it is important to identify factors that affect stent patency and failure. We examined the patency of endoscopically placed SEMS in patients with hilar cholangiocarcinoma and factors associated with patency. We performed a retrospective study of 120 consecutive patients (mean age, 67 ± 14.6 years; 74 male) who presented with obstructive jaundice from hilar cholangiocarcinoma and underwent bilateral SEMS from September 2006 through April 2012 at 2 US tertiary medical centers. We collected data on patient demographics and survival, success of stent placement and function, and immediate adverse events. The primary outcome was duration of stent patency (time from insertion to failure). Thirty-eight patients had stage 1 hilar cholangiocarcinomas, 45 had stage 2, 12 had stage 3, and 25 had stage 4. The median length of the hilar stricture was 9 mm (range, 8-50 mm). The stent was successfully passaged across the stricture in all patients and was functional in 115; its median length was 8 mm (range, 8-10 mm), and diameter was 80 mm (range, 60-100 mm). Fourteen patients had immediate adverse events, including perforation (n = 2), bleeding (n = 2), pancreatitis (n = 9), and cholangitis (n = 1). Median survival was 17 weeks (range, 1-211 weeks), and 50 patients had stent occlusion. On Kaplan-Meier analysis, the median time from stent placement to occlusion was 17 weeks (range, 1-104 weeks). More patients with stage 3 or 4 tumors (64%) had SEMS occlusion than patients with stage 1 or 2 tumors (28%) in univariate analysis (P = .017). In multivariate analysis, only cancer stage was independently and significantly associated with patency (P = .006; hazard ratio, 2.77); age, sex, length of stricture, and SEMS diameter and length were not. The cumulative patency of bilateral SEMS for hilar cholangiocarcinoma significantly decreases as tumor stage increases. Age, sex, length of stricture, and SEMS diameter and length are not associated with SEMS patency. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.
Group Waterpipe Tobacco Smoking Increases Smoke Toxicant Concentration
Ramôa, Carolina P.; Shihadeh, Alan; Salman, Rola
2016-01-01
Abstract Introduction: Waterpipe tobacco smoking is a global health concern. Laboratory research has focused on individual waterpipe users while group use is common. This study examined user toxicant exposure and smoke toxicant yield associated with individual and group waterpipe smoking. Methods: Twenty-two pairs of waterpipe smokers used a waterpipe individually and as a dyad. Before and after smoking, blood was sampled and expired carbon monoxide (CO) measured; puff topography was recorded throughout. One participant from each pair was selected randomly and their plasma nicotine and expired air CO concentrations were compared when smoking alone to when smoking as part of a dyad. Recorded puff topography was used to machine-produce smoke that was analyzed for toxicant content. Results: There was no difference in mean plasma nicotine concentration when an individual smoked as part of a dyad (mean = 14.9ng/ml; standard error of the mean [ SEM ] = 3.0) compared to when smoking alone (mean = 10.0ng/ml; SEM = 1.5). An individual smoking as part of as a dyad had, on average, lower CO (mean = 15.8 ppm; SEM = 2.0) compared to when smoking alone (mean= 21.3 ppm; SEM = 2.7). When two participants smoked as a dyad they took, on average, more puffs (mean = 109.8; SEM = 7.6) than a singleton smoker (mean = 77.7; SEM = 8.1) and a shorter interpuff interval (IPI; dyad mean = 23.8 seconds; SEM = 1.9; singleton mean = 40.8 seconds; SEM = 4.8). Higher concentrations of several toxicants were observed in dyad-produced smoke. Discussion: Dyad smoking may increase smoke toxicant content, likely due to the dyad’s shorter IPIs and greater puff number. More work is needed to understand if group waterpipe smoking alters the health risks of waterpipe tobacco smoking. Implications: This study is the first to measure toxicants in smoke generated from a waterpipe when used by a dyad. Relative to smoke generated by a singleton, dyad smoke had higher concentration of some toxicants. These differences may be attributed to differences in puffing behavior, specifically the shorter IPI and greater puff number observed in the dyad condition. Relative to singleton smokers, dyad smokers were exposed to less CO, but nicotine exposure did not differ. More work is needed to assess the health effects of inhalation of more toxicant-laden smoke during group waterpipe use. PMID:26659913
Determination of anisotropy and multimorphology in fly ash based geopolymers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, M. Irfan, E-mail: mirfanwazir@gmail.com; Azizli, Khairun, E-mail: khairun-azizli@petronas.com.my; Sufian, Suriati, E-mail: suriati@petronas.com.my
2015-07-22
In this study, Malaysian coal fly ash-based geopolymers were investigated for its morphology and chemical composition using scanning electron microscopy coupled with energy dispersive X-rays (SEM-EDX). Geopolymer was synthesized using sodium hydroxide as activator. SEM studies revealed multiphasous structure of the material, composed of geopolymeric gel, partially reacted fly ashparticles and selectively leached particles. EDX analysis confirmed the chemical composition of different regions. Infra red spectroscopic studies supported the SEM-EDX analysis by confirming presence of unreacted quartzite and mullite in geopolymers. It is concluded that geopolymers possese a non uniform chemistry through out the structure.
Determination of anisotropy and multimorphology in fly ash based geopolymers
NASA Astrophysics Data System (ADS)
Khan, M. Irfan; Azizli, Khairun; Sufian, Suriati; Man, Zakaria; Siyal, Ahmer Ali; Ullah, Hafeez
2015-07-01
In this study, Malaysian coal fly ash-based geopolymers were investigated for its morphology and chemical composition using scanning electron microscopy coupled with energy dispersive X-rays (SEM-EDX). Geopolymer was synthesized using sodium hydroxide as activator. SEM studies revealed multiphasous structure of the material, composed of geopolymeric gel, partially reacted fly ashparticles and selectively leached particles. EDX analysis confirmed the chemical composition of different regions. Infra red spectroscopic studies supported the SEM-EDX analysis by confirming presence of unreacted quartzite and mullite in geopolymers. It is concluded that geopolymers possese a non uniform chemistry through out the structure.
The Scanning Electron Microscope As An Accelerator For The Undergraduate Advanced Physics Laboratory
NASA Astrophysics Data System (ADS)
Peterson, Randolph S.; Berggren, Karl K.; Mondol, Mark
2011-06-01
Few universities or colleges have an accelerator for use with advanced physics laboratories, but many of these institutions have a scanning electron microscope (SEM) on site, often in the biology department. As an accelerator for the undergraduate, advanced physics laboratory, the SEM is an excellent substitute for an ion accelerator. Although there are no nuclear physics experiments that can be performed with a typical 30 kV SEM, there is an opportunity for experimental work on accelerator physics, atomic physics, electron-solid interactions, and the basics of modern e-beam lithography.
Surface topography characterization using 3D stereoscopic reconstruction of SEM images
NASA Astrophysics Data System (ADS)
Vedantha Krishna, Amogh; Flys, Olena; Reddy, Vijeth V.; Rosén, B. G.
2018-06-01
A major drawback of the optical microscope is its limitation to resolve finer details. Many microscopes have been developed to overcome the limitations set by the diffraction of visible light. The scanning electron microscope (SEM) is one such alternative: it uses electrons for imaging, which have much smaller wavelength than photons. As a result high magnification with superior image resolution can be achieved. However, SEM generates 2D images which provide limited data for surface measurements and analysis. Often many research areas require the knowledge of 3D structures as they contribute to a comprehensive understanding of microstructure by allowing effective measurements and qualitative visualization of the samples under study. For this reason, stereo photogrammetry technique is employed to convert SEM images into 3D measurable data. This paper aims to utilize a stereoscopic reconstruction technique as a reliable method for characterization of surface topography. Reconstructed results from SEM images are compared with coherence scanning interferometer (CSI) results obtained by measuring a roughness reference standard sample. This paper presents a method to select the most robust/consistent surface texture parameters that are insensitive to the uncertainties involved in the reconstruction technique itself. Results from the two-stereoscopic reconstruction algorithms are also documented in this paper.
SEM Analysis of Surface Impact on Biofilm Antibiotic Treatment.
Gomes, Luciana Calheiros; Mergulhão, Filipe José
2017-01-01
The aim of this work was to use scanning electron microscopy (SEM) to investigate the effect of ampicillin treatment on Escherichia coli biofilms formed on two surface materials with different properties, silicone (SIL) and glass (GLA). Epifluorescence microscopy (EM) was initially used to assess biofilm formation and killing efficiency on both surfaces. This technique showed that higher bacterial colonization was obtained in the hydrophobic SIL than in the hydrophilic GLA. It has also shown that higher biofilm inactivation was attained for GLA after the antibiotic treatment (7-log reduction versus 1-log reduction for SIL). Due to its high resolution and magnification, SEM enabled a more detailed analysis of the antibiotic effect on biofilm cells, complementing the killing efficiency information obtained by EM. SEM micrographs revealed that ampicillin-treated cells have an elongated form when compared to untreated cells. Additionally, it has shown that different materials induced different levels of elongation on cells exposed to antibiotic. Biofilms formed on GLA showed a 37% higher elongation than those formed on SIL. Importantly, cell elongation was related to viability since ampicillin had a higher bactericidal effect on GLA-formed biofilms. These findings raise the possibility of using SEM for understanding the efficacy of antimicrobial treatments by observation of biofilm morphology.
Geiser, Christian; Bishop, Jacob; Lockhart, Ginger; Shiffman, Saul; Grenard, Jerry L.
2013-01-01
Latent state-trait (LST) and latent growth curve (LGC) models are frequently used in the analysis of longitudinal data. Although it is well-known that standard single-indicator LGC models can be analyzed within either the structural equation modeling (SEM) or multilevel (ML; hierarchical linear modeling) frameworks, few researchers realize that LST and multivariate LGC models, which use multiple indicators at each time point, can also be specified as ML models. In the present paper, we demonstrate that using the ML-SEM rather than the SL-SEM framework to estimate the parameters of these models can be practical when the study involves (1) a large number of time points, (2) individually-varying times of observation, (3) unequally spaced time intervals, and/or (4) incomplete data. Despite the practical advantages of the ML-SEM approach under these circumstances, there are also some limitations that researchers should consider. We present an application to an ecological momentary assessment study (N = 158 youths with an average of 23.49 observations of positive mood per person) using the software Mplus (Muthén and Muthén, 1998–2012) and discuss advantages and disadvantages of using the ML-SEM approach to estimate the parameters of LST and multiple-indicator LGC models. PMID:24416023
Dealing with Multiple Solutions in Structural Vector Autoregressive Models.
Beltz, Adriene M; Molenaar, Peter C M
2016-01-01
Structural vector autoregressive models (VARs) hold great potential for psychological science, particularly for time series data analysis. They capture the magnitude, direction of influence, and temporal (lagged and contemporaneous) nature of relations among variables. Unified structural equation modeling (uSEM) is an optimal structural VAR instantiation, according to large-scale simulation studies, and it is implemented within an SEM framework. However, little is known about the uniqueness of uSEM results. Thus, the goal of this study was to investigate whether multiple solutions result from uSEM analysis and, if so, to demonstrate ways to select an optimal solution. This was accomplished with two simulated data sets, an empirical data set concerning children's dyadic play, and modifications to the group iterative multiple model estimation (GIMME) program, which implements uSEMs with group- and individual-level relations in a data-driven manner. Results revealed multiple solutions when there were large contemporaneous relations among variables. Results also verified several ways to select the correct solution when the complete solution set was generated, such as the use of cross-validation, maximum standardized residuals, and information criteria. This work has immediate and direct implications for the analysis of time series data and for the inferences drawn from those data concerning human behavior.
[Evaluation of three methods for forensic diatom test].
Wang, Yuzhong; Zhao, Jian; Li, Peng; Hu, Sunlin; Wang, Huipin; Wang, Huijun; Liu, Chao
2015-03-01
To compare the efficacy of three methods for forensic diatom test, namely strong acid digestion-centrifuge enrichment-light microscopy (SD-CE-LM), microwave digestion-membrane filtration-automated scanning electron microscopy (MD-ME-SEM), and microwave digestion-membrane filtration-light microscopy (MD-MF-LM). Sixty samples were randomly divided into 3 groups for diatom test using three methods, and the sample preparation time, degree of digestion and recovery rate of diatoms were compared. The sample preparation time was the shortest with MD-MF-LM and the longest with SD-CE-LM (P<0.05). MD-ME-SEM and MD-MF-LM allowed more thorough tissue digestion than SD-CE-LM. MD-ME-SEM resulted in the highest total recovery rate of diatom, followed by MD-MF-LM and then by SD-CE-LM (P<0.05); the recover rate of different diatom species was the highest with MD-ME-SEM, followed by MD-MF-LM and SD-CE-LM (P<0.05). SD-CE-LM has a low recovery rate of diatoms especially for those with lengths shorter than 40 µm or densities less than 1/5. With a high recovery rate and accuracy in diatom test, MD-ME-SEM is suitable for diagnosis of suspected drowning cases. MD-MF-LM is highly efficient, sensitive and convenient for forensic diatom test.
Measurement of elasticity and transepidermal water loss rate of burn scars with the Dermalab(®).
Anthonissen, Mieke; Daly, Daniel; Fieuws, Steffen; Massagé, Patrick; Van Brussel, Michel; Vranckx, Jan; Van den Kerckhove, Eric
2013-05-01
This cross-sectional study investigated the reproducibility of repeated elasticity and transepidermal water loss (TEWL) measurements with the DermaLab(®) on 32 active burn scars and healthy skin. Intra- and inter-observer reproducibility was examined by means of intra-class correlation coefficients (ICC) and standard error of measurements (SEM). Results showed good ICC values and rather high SEM values for inter- and intra-observer reproducibility of elasticity measurements. For TEWL measurements, ICC values were good and SEM values were high for inter- and intra-observer reproducibility. There was a significant difference between the estimated mean elasticity values of normal skin and grafted scars and between normal skin and spontaneously healed scars (p≤0.003). For the estimated mean TEWL values, there was a significant difference between normal skin and spontaneously healed scars (p=0.036). A significant negative relation was reported between mean TEWL and time after burn (p=0.008). In clinical trials it is necessary to interpret patient-specific changes in elasticity and TEWL with caution, since the SEMs of both modes are rather high. We therefore recommend the use of a mean of repeated measurements of elasticity and TEWL to decrease the SEM. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.
Are the evidences of forensic entomology preserved in ethanol suitable for SEM studies?
López-Esclapez, Raquel; García, María-Dolores; Arnaldos, María-Isabel; Presa, Juan José; Ubero-Pascal, Nicolás
2014-07-01
In forensic practice, the use of arthropod evidences to estimate the postmortem interval is a very good approach when the elapsed time from death is long, but it requires the correct identification of the specimens. This is a crucial step, not always easy to achieve, in particular when dealing with immature specimens. In this case, scanning electronic microscopy (SEM) can be useful, but the techniques used to preserve specimens in forensic practice are usually different from those used to prepare specimens for SEM studies. To determine whether forensic evidences preserving techniques are also compatible with SEM analysis, we have compared specimens of all the immature stages of Calliphora vicina Robineau-Desvoidy, 1830 (Diptera, Calliphoridae) preserved in 70% ethanol, with others prepared with aldehydic fixative techniques that are more appropriate for SEM studies. At the same time, two drying techniques have also been compared with both fixative techniques, the critical point drying and air-drying following with hexamethyldisilizane treatment (HMDS). Our results indicate that there are not basis against recommending the use of ethanol to preserve forensic entomological evidences and that both drying methods appear to offer good results for second and third instar larvae, although HMDS behaves better with eggs and pupae. Copyright © 2014 Elsevier Ltd. All rights reserved.
Depth-section imaging of swine kidney by spectrally encoded microscopy
NASA Astrophysics Data System (ADS)
Liao, Jiuling; Gao, Wanrong
2016-10-01
The kidneys are essential regulatory organs whose main function is to regulate the balance of electrolytes in the blood, along with maintaining pH homeostasis. The study of the microscopic structure of the kidney will help identify kidney diseases associated with specific renal histology change. Spectrally encoded microscopy (SEM) is a new reflectance microscopic imaging technique in which a grating is used to illuminate different positions along a line on the sample with different wavelengths, reducing the size of system and imaging time. In this paper, a SEM device is described which is based on a super luminescent diode source and a home-built spectrometer. The lateral resolution was measured by imaging the USAF resolution target. The axial response curve was obtained as a reflect mirror was scanned through the focal plane axially. In order to test the feasibility of using SEM for depth-section imaging of an excised swine kidney tissue, the images of the samples were acquired by scanning the sample at 10 μm per step along the depth direction. Architectural features of the kidney tissue could be clearly visualized in the SEM images, including glomeruli and blood vessels. Results from this study suggest that SEM may be useful for locating regions with probabilities of kidney disease or cancer.
[Sem: a suitable statistical software adaptated for research in oncology].
Kwiatkowski, F; Girard, M; Hacene, K; Berlie, J
2000-10-01
Many softwares have been adapted for medical use; they rarely enable conveniently both data management and statistics. A recent cooperative work ended up in a new software, Sem (Statistics Epidemiology Medicine), which allows data management of trials and, as well, statistical treatments on them. Very convenient, it can be used by non professional in statistics (biologists, doctors, researchers, data managers), since usually (excepted with multivariate models), the software performs by itself the most adequate test, after what complementary tests can be requested if needed. Sem data base manager (DBM) is not compatible with usual DBM: this constitutes a first protection against loss of privacy. Other shields (passwords, cryptage...) strengthen data security, all the more necessary today since Sem can be run on computers nets. Data organization enables multiplicity: forms can be duplicated by patient. Dates are treated in a special but transparent manner (sorting, date and delay calculations...). Sem communicates with common desktop softwares, often with a simple copy/paste. So, statistics can be easily performed on data stored in external calculation sheets, and slides by pasting graphs with a single mouse click (survival curves...). Already used over fifty places in different hospitals for daily work, this product, combining data management and statistics, appears to be a convenient and innovative solution.
Miniature Variable Pressure Scanning Electron Microscope for In-Situ Imaging and Chemical Analysis
NASA Technical Reports Server (NTRS)
Gaskin, Jessica A.; Jerman, Gregory; Gregory, Don; Sampson, Allen R.
2012-01-01
NASA Marshall Space Flight Center (MSFC) is leading an effort to develop a Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for in-situ imaging and chemical analysis of uncoated samples. This instrument development will be geared towards operation on Mars and builds on a previous MSFC design of a mini-SEM for the moon (funded through the NASA Planetary Instrument Definition and Development Program). Because Mars has a dramatically different environment than the moon, modifications to the MSFC lunar mini-SEM are necessary. Mainly, the higher atmospheric pressure calls for the use of an electron gun that can operate at High Vacuum, rather than Ultra-High Vacuum. The presence of a CO2-rich atmosphere also allows for the incorporation of a variable pressure system that enables the in-situ analysis of nonconductive geological specimens. Preliminary testing of Mars meteorites in a commercial Environmental SEM(Tradmark) (FEI) confirms the usefulness of lowcurrent/low-accelerating voltage imaging and highlights the advantages of using the Mars atmosphere for environmental imaging. The unique capabilities of the MVP-SEM make it an ideal tool for pursuing key scientific goals of NASA's Flagship Mission Max-C; to perform in-situ science and collect and cache samples in preparation for sample return from Mars.
Tang, Chih-Yuan; Huang, Rong-Nan; Kuo-Huang, Ling-Long; Kuo, Tai-Chih; Yang, Ya-Yun; Lin, Ching-Yeh; Jane, Wann-Neng; Chen, Shiang-Jiuun
2012-02-01
A pre-cryogenic holder (cryo-holder) facilitating cryo-specimen observation under a conventional scanning electron microscope (SEM) is described. This cryo-holder includes a specimen-holding unit (the stub) and a cryogenic energy-storing unit (a composite of three cylinders assembled with a screw). After cooling, the cryo-holder can continue supplying cryogenic energy to extend the observation time for the specimen in a conventional SEM. Moreover, the cryogenic energy-storing unit could retain appropriate liquid nitrogen that can evaporate to prevent frost deposition on the surface of the specimen. This device is proved feasible for various tissues and cells, and can be applied to the fields of both biology and material science. We have employed this novel cryo-holder for observation of yeast cells, trichome, and epidermal cells in the leaf of Arabidopsis thaliana, compound eyes of insects, red blood cells, filiform papillae on the surface of rat tongue, agar medium, water molecules, penicillium, etc. All results suggested that the newly designed cryo-holder is applicable for cryo-specimen observation under a conventional SEM without cooling system. Most importantly, the design of this cryo-holder is simple and easy to operate and could adapt a conventional SEM to a plain type cryo-SEM affordable for most laboratories. Copyright © 2011 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Zhang, Jiping; Hu, Jiwei; Huang, Xianfei; Shen, Wei; Jin, Mei; Fu, Liya; Jin, Xiaofei
2013-09-01
The bioavailability of five divalent cationic heavy metals (Pb, Cd, Cu, Zn and Ni) in 10 superficial sediment samples from Baihua Lake was assessed based on the molar ratio of simultaneously extracted metals (SEMs) to acid volatile sulfide (AVS). Atomic absorption spectrometry (AAS) and X-ray powder diffraction (XRD) were used to determine the heavy metal concentrations and examine the mineralogy of the crystalline phases, respectively. The AVS loadings in sediments from Baihua Lake ranged from 64.30 to 350.08 μmol/g (dry weight). The corresponding SEM levels for the sampling sites varied from 1.770 to 14.660 μmol/g. The molar ratio of SEMs to AVS ranged from 0.014 to 0.084 with a mean value of 0.034. The XRD analysis also confirmed the presence of some metal sulfides in sediments from Baihua Lake. The SEMs/AVS ratios for all sampling sites were significantly lower than 1.0, indicating that AVS in the sediments was sufficient to bind the five heavy metals; thus, these heavy metals are currently not significantly bioavailable to benthic organisms. Comparing the SEMs results to published guideline values for metal toxicity to benthic organisms in sediments, however, suggests that Zn and Ni pose a risk at some sampling locations in Baihua Lake.
NASA Astrophysics Data System (ADS)
Hamers, Maartje F.; Pennock, Gill M.; Herwegh, Marco; Drury, Martyn R.
2016-10-01
Planar deformation features (PDFs) in quartz are one of the most reliable and most widely used forms of evidence for hypervelocity impact. PDFs can be identified in scanning electron microscope cathodoluminescence (SEM-CL) images, but not all PDFs show the same CL behavior: there are nonluminescent and red luminescent PDFs. This study aims to explain the origin of the different CL emissions in PDFs. Focused ion beam (FIB) thin foils were prepared of specific sample locations selected in composite color SEM-CL images and were analyzed in a transmission electron microscope (TEM). The FIB preparation technique allowed a direct, often one-to-one correlation between the CL images and the defect structure observed in TEM. This correlation shows that composite color SEM-CL imaging allows distinction between amorphous PDFs on one hand and healed PDFs and basal Brazil twins on the other: nonluminescent PDFs are amorphous, while healed PDFs and basal Brazil twins are red luminescent, with a dominant emission peak at 650 nm. We suggest that the red luminescence is the result of preferential beam damage along dislocations, fluid inclusions, and twin boundaries. Furthermore, a high-pressure phase (possibly stishovite) in PDFs can be detected in color SEM-CL images by its blue luminescence.
Almadi, Majid A; Barkun, Alan; Martel, Myriam
2017-02-01
Self-expandable metal stents (SEMS) are thought to have an advantage over plastic stents in achieving biliary drainage. We performed a systematic search of MEDLINE, EMBASE, Scopus, CENTRAL, and ISI Web of knowledge databases, from January 1980 to September 2015, for randomized-controlled trials (RCTs) comparing SEMS vs. plastic stents in the palliation of malignant biliary obstruction. Primary outcomes were durations of stent patency, patient survival, and 30-day mortality. Numerous secondary outcomes were assessed, and extensive sensitivity and subgroup analyses were performed. In all, 20 RCTs totaling 1,713 patients yielded a weighted mean difference (WMD) in time to stent patency (4 studies) of 4.45 months (95% confidence interval (CI), 0.31, 8.59; GRADE=moderate) favoring SEMS. There were no differences in overall patient survival (5 studies) WMD=0.67 months (95% CI, -0.66, 1.99; GRADE=moderate), or 30-day mortality (8 studies) odds ratio (OR)=0.80 (95% CI, 0.52, 1.24; GRADE=moderate) but there was a higher symptom-free survival at 6 months (4 studies) OR=5.96 (95% CI, 1.71, 20.81; GRADE=moderate). SEMS use resulted in lower rates of late complications (11 studies) OR=0.43 (95% CI, 0.26, 0.71; GRADE=moderate), sepsis or cholangitis (14 studies) OR=0.53 (95% CI, 0.37, 0.77; GRADE=high), blocking from sludge (8 studies) OR=0.11(95% CI, 0.07, 0.17; GRADE=moderate), and mean number of re-interventions (8 studies) WMD=-0.83 interventions (95% CI, -1.64, -0.02; GRADE=moderate). There was a longer patency of SEMS for those without a prior drainage attempt (2 studies) WMD 7.70 months (95% CI, 7.14, 8.25; GRADE=high). Although a survival advantage was found when an uncovered SEMS was used (3 studies) WMD 1.31 months (95% CI, 0.30, 2.32; GRADE=high), but not partially or fully covered SEMS (2 studies) WMD -0.66 months (95% CI, -1.02, -0.30; GRADE=high) vs. plastic stents, and for SEMS in the setting of pre- or post-procedural antibiotic administration (2 studies) WMD 1.49 months (95% CI, 0.27, 2.70; GRADE=high), and performance of a sphincterotomy (2 studies) WMD 1.63 months (95% CI, 0.42, 2.84; GRADE=high). Keeping in mind the noted risk of bias in source data, the use of SEMS compared with plastic stents, in the palliation of patients with malignant biliary obstruction results in longer stent patency, lower complications rates, and fewer re-interventions, whereas exhibiting survival benefits in selected subgroups of patients.
Puchala, R; Animut, G; Patra, A K; Detweiler, G D; Wells, J E; Varel, V H; Sahlu, T; Goetsch, A L
2012-08-01
Twenty-four yearling Boer × Spanish wethers were used to assess effects of different forages, either fresh (Exp. 1) or as hay (Exp. 2), on feed intake, digestibilities, heat production, and ruminal methane emission. Treatments were: 1) Sericea lespedeza (SER; Lespedeza cuneata), a legume high in condensed tannins (CT; 20% and 15% in fresh forage and hay, respectively), 2) SER supplemented with polyethylene glycol (SER-PEG; 25 g/d), 3) alfalfa (Medicago sativa), a legume low in CT (ALF), and 4) sorghum-sudangrass (Sorghum bicolor), a grass low in CT (GRASS). Experiments were 22 d, which included 16 d for acclimatization followed by a 6-d period for fecal and urine collection, and gas exchange measurement (last 2 d). Intake of OM was 867, 823, 694, and 691 g/d (SEM = 20.1) with fresh forage, and 806, 887, 681, and 607 g/d with hay for SER, SER-PEG, ALF, and GRASS, respectively (SEM = 46.6). Apparent total tract N digestion was greater for SER-PEG vs. SER (P < 0.001) with fresh forage (46.3%, 66.5%, 81.7%, and 73.2%; SEM = 1.71) and hay (49.7%, 71.4%, 65.4%, and 54.8% for SER, SER-PEG, ALF, and GRASS, respectively; SEM = 1.57). Intake of ME was similar among treatments with fresh forage (8.24, 8.06, 7.42, and 7.70 MJ/d; SEM = 0.434) and with hay was greater for SER-PEG than ALF (P < 0.03) and GRASS (P < 0.001) (8.63, 10.40, 8.15, and 6.74 MJ/d for SER, SER-PEG, ALF, and GRASS, respectively; SEM = 0.655). The number of ciliate protozoa in ruminal fluid was least for SER with fresh forage (P < 0.01) (9.8, 20.1, 21.0, and 33.6 × 10(5)/ml; SEM = 2.76) and hay (P < 0.02) (6.3, 11.4, 13.6, and 12.5 × 10(5)/ml for SER, SER-PEG, ALF, and GRASS, respectively; SEM = 1.43). Methane emission as a percentage of DE intake was lower (P < 0.01) for SER vs. ALF and GRASS with fresh forage (6.6, 8.3, 9.4, and 9.2%; SEM = 0.64) and hay (4.3, 4.9, 6.4, and 6.7% for SER, SER-PEG, ALF, and GRASS, respectively; SEM = 0.38). In summary, methane emission in this short-term experiment was similar between a legume and grass low in CT as fresh forage and hay. The CT in SER markedly decreased N digestibility and elicited a moderate decline in ruminal methane emission. Supplementation with PEG alleviated the effect of CT on N digestibility but not ruminal methane emission, presumably because of different modes of action. In conclusion, potential of using CT-containing forage as a means of decreasing ruminal methane emission requires further study, such as with longer feeding periods.
Matte, J Jacques; Corrent, Etienne; Simongiovanni, Aude; Le Floc'h, Nathalie
2016-05-01
The present experiment aimed to determine if Trp metabolism and growth responses to dietary Trp are modulated by dietary niacin (B) in weanling piglets. Piglets weaned at 3 wk of age were distributed 1 wk later (7.6 kg of BW, SEM = 0.1) in 52 pens of 2 animals each. Pens were assigned to factorial dietary treatments with 2 additions of B, 15 mg/kg (LB3) vs. 45 mg/kg (HB3) and 2 additions of Trp, 0 mg/kg (-Trp) vs. 1 mg/kg (+Trp) for Trp to Lys ratios of 0.16 vs. 0.24, respectively. Growth performance was recorded every week from 4 to 10 wk of age. Fasting blood samples were taken at 4, 6, 8, and 10 wk of age. From 4 to 10 wk of age, ADFI tended to be greater ( = 0.10) in HB3 than in LB3 (1,031 vs. 1,003 g, SEM = 7), and this was reflected ( = 0.06) by ADG (642 vs. 623 g, SEM = 7). No treatment effect was observed on plasma Trp or kynurenine (Kyn), an intermediate metabolite of Trp catabolism. The response of plasma nicotinamide (Nam), a product of Trp catabolism and an indicator of B status, to dietary B differed according to treatments (interaction Trp × B, < 0.01) with values of 1.4, 3.3, 4.1, and 5.3 μM (SEM = 0.1) in LB3-Trp, HB3-Trp, LB3+Trp, and HB3+Trp, respectively. At 11 wk of age, postprandial blood samples were collected from 6 piglets per treatment for measurements of Trp and insulin metabolism. Postprandial plasma Trp (96.4 vs. 72.2 μ, SEM = 3.4) and Kyn (1.7 vs. 1.3 μ, SEM = 0.1) were greater ( < 0.01) in +Trp vs. -Trp. Postprandial plasma Nam was greater ( < 0.01) in +Trp vs. -Trp (3.4 vs. 1.9 µ, SEM = 0.3) and in HB3 vs. LB3 piglets (3.4 vs. 1.9 µ, SEM = 0.3). Postprandial peaks and areas under curves of C-peptide and glucose were not affected by treatments. However, for insulin, the postprandial peak was lower in +Trp vs. -Trp piglets in the LB3 group (interaction Trp × B, < 0.05); values were 1.3, 1.0, 0.7, and 1.0 n (SEM = 0.1) in LB3-Trp, HB3-Trp, LB3+Trp, and HB3+Trp, respectively. The peak value of the molar ratio insulin:C-peptide was lower ( < 0.02) in +Trp vs. -Trp piglets (0.56 vs. 0.73, SEM = 0.05). The responses observed on growth performance and plasma Nam suggest that the LB3 level was suboptimal. According also to plasma Nam, it appears that supplemental dietary B can attenuate Trp oxidation toward niacin metabolites. Postprandial profiles of insulin and C-peptide indicate that Trp action is exerted on insulin clearance rather than on insulin secretion in piglets, without apparent consequences on glucose utilization.
USING STRUCTURAL EQUATION MODELING TO INVESTIGATE RELATIONSHIPS AMONG ECOLOGICAL VARIABLES
This paper gives an introductory account of Structural Equation Modeling (SEM) and demonstrates its application using LISREL< with a model utilizing environmental data. Using nine EMAP data variables, we analyzed their correlation matrix with an SEM model. The model characterized...
Ahmed, Hany Mohamed Aly; Luddin, Norhayati; Kannan, Thirumulu Ponnuraj; Mokhtar, Khairani Idah; Ahmad, Azlina
2014-10-01
The attachment and spreading of mammalian cells on endodontic biomaterials are an area of active research. The purpose of this review is to discuss the cell attachment properties of Portland cement (PC)-based materials by using scanning electron microscope (SEM). In addition, methodological aspects and technical challenges are discussed. A PubMed electronic search was conducted by using appropriate key words to identify the available investigations on the cell attachment properties of PC-based endodontic materials. After retrieving the full text of related articles, the cross citations were also identified. A total of 23 articles published between January 1993 and October 2013 were identified. This review summarizes the cell attachment properties of commercial and experimental PC-based materials on different cell cultures by using SEM. Methodological procedures, technical challenges, and relevance of SEM in determining the biological profile of PC-based materials are discussed. SEM observations demonstrate that commercial MTA formulations show favorable cell attachment properties, which is consistent with their successful clinical outcomes. The favorable cell attachment properties of PC and its modified formulations support its potential use as a substitute for mineral trioxide aggregate. However, researchers should carefully select cell types for their SEM investigations that would be in contact with the proposed PC-based combinations in the clinical situation. Despite being a technical challenge, SEM provides useful information on the cell attachment properties of PC-based materials; however, other assays for cell proliferation and viability are essential to come up with an accurate in vitro biological profile of any given PC-based formulation. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Kerdsirichairat, Tossapol; Arain, Mustafa A; Attam, Rajeev; Glessing, Brooke; Bakman, Yan; Amateau, Stuart K; Freeman, Martin L
2017-01-01
Objectives: Endoscopic drainage of complex hilar tumors has generally resulted in poor outcomes. Drainage of >50% of liver volume has been proposed as optimal, but not evaluated using long multifenestrated plastic stents (MFPS) or self-expanding metal stents (SEMS). We evaluated outcomes of endoscopic drainage of malignant hilar strictures using optimal strategy and stents, and determined factors associated with stent patency, survival, and complications. Methods: Cross-sectional study was conducted at an academic center over 5 years. MFPS (10 French or 8.5 French) or open-cell SEMS were used for palliation of unresectable malignant hilar strictures, with imaging-targeted drainage of as many sectors as needed to drain >50% of viable liver volume. Risk factors were evaluated using regression analysis. The cumulative risk was assessed using Kaplan–Meier analysis. Results: 77 patients with malignant hilar biliary strictures (median Bismuth IV) underwent targeted stenting (41 MFPS and 36 SEMS). Comparing MFPS vs. SEMS, technical success (95.1 vs. 97.2%, P=0.64), clinical success (75.6 vs. 83.3%, P=0.40), frequency of multiple stents (23/41 vs. 25/36, P=0.19), survival and adverse events were similar, but stent patency was significantly shorter (P<0.0001). Factors associated with survival were Karnofsky score and serum bilirubin level at presentation. Outcomes were independent of Bismuth class with acceptable results in Bismuth III and IV. Conclusions: Endoscopic biliary drainage with MFPS or open-cell SEMS targeting >50% of viable liver resulted in effective palliation in patients with complex malignant hilar biliary strictures. Patency was shorter in the MFPS group, but similar survival and complications were found when comparing MFPS and SEMS group. PMID:28858292
Kerdsirichairat, Tossapol; Arain, Mustafa A; Attam, Rajeev; Glessing, Brooke; Bakman, Yan; Amateau, Stuart K; Freeman, Martin L
2017-08-31
Endoscopic drainage of complex hilar tumors has generally resulted in poor outcomes. Drainage of >50% of liver volume has been proposed as optimal, but not evaluated using long multifenestrated plastic stents (MFPS) or self-expanding metal stents (SEMS). We evaluated outcomes of endoscopic drainage of malignant hilar strictures using optimal strategy and stents, and determined factors associated with stent patency, survival, and complications. Cross-sectional study was conducted at an academic center over 5 years. MFPS (10 French or 8.5 French) or open-cell SEMS were used for palliation of unresectable malignant hilar strictures, with imaging-targeted drainage of as many sectors as needed to drain >50% of viable liver volume. Risk factors were evaluated using regression analysis. The cumulative risk was assessed using Kaplan-Meier analysis. 77 patients with malignant hilar biliary strictures (median Bismuth IV) underwent targeted stenting (41 MFPS and 36 SEMS). Comparing MFPS vs. SEMS, technical success (95.1 vs. 97.2%, P=0.64), clinical success (75.6 vs. 83.3%, P=0.40), frequency of multiple stents (23/41 vs. 25/36, P=0.19), survival and adverse events were similar, but stent patency was significantly shorter (P<0.0001). Factors associated with survival were Karnofsky score and serum bilirubin level at presentation. Outcomes were independent of Bismuth class with acceptable results in Bismuth III and IV. Endoscopic biliary drainage with MFPS or open-cell SEMS targeting >50% of viable liver resulted in effective palliation in patients with complex malignant hilar biliary strictures. Patency was shorter in the MFPS group, but similar survival and complications were found when comparing MFPS and SEMS group.
Febiyanto, Novian; Yamazaki, Chiho; Kameo, Satomi; Sari, Dian K; Puspitasari, Irma M; Sunjaya, Deni K; Herawati, Dewi M D; Nugraha, Gaga I; Fukuda, Toshio; Koyama, Hiroshi
2018-01-01
Oxidative stress in obesity leads to insulin resistance in type 2 diabetes. Some selenoproteins possess antioxidant properties, suggesting that selenium (Se) may protect against type 2 diabetes; however, evidence from epidemiological studies is contradictory. We hypothesized that Se status before supplementation (baseline) contributes to the supplementation outcome. This study aimed to clarify the influence of baseline Se status on the effect of Se supplementation on the diabetic condition. Six-week-old KKAy mice were fed a diet without supplemental Se or with 0.1 ppm Se in the form of L-selenomethionine (SeM) for 2 weeks to create low-Se and sufficient-Se baseline statuses, respectively. For the next 4 weeks, low-Se mice were given a SeM (0.5 ppm Se)-supplemented diet, and sufficient-Se mice were given either a SeM (0.5 ppm Se)- or sodium selenite (0.5 ppm Se)-supplemented diet; control groups continued on baseline diets. Serum Se concentrations, glutathione peroxidase (GPx) activities, adiponectin levels, glucose tolerance, and insulin sensitivity were analyzed. All mice became diabetic during the 2-week baseline induction period. At the end of the supplementation period, Se-receiving groups demonstrated significantly higher Se concentrations and GPx activities than their respective controls. Sufficient-Se mice receiving SeM had lower blood glucose levels and better insulin sensitivity than control and sodium selenite-receiving mice, whereas low-Se mice receiving SeM showed no such improvements compared with their controls. Our results suggest that Se supplementation in the form of SeM may help prevent type 2 diabetes aggravation in people taking the 55 μg/day Se recommended dietary allowance.
Guehrs, Erik; Schneider, Michael; Günther, Christian M; Hessing, Piet; Heitz, Karen; Wittke, Doreen; López-Serrano Oliver, Ana; Jakubowski, Norbert; Plendl, Johanna; Eisebitt, Stefan; Haase, Andrea
2017-03-21
Quantification of nanoparticle (NP) uptake in cells or tissues is very important for safety assessment. Often, electron microscopy based approaches are used for this purpose, which allow imaging at very high resolution. However, precise quantification of NP numbers in cells and tissues remains challenging. The aim of this study was to present a novel approach, that combines precise quantification of NPs in individual cells together with high resolution imaging of their intracellular distribution based on focused ion beam/ scanning electron microscopy (FIB/SEM) slice and view approaches. We quantified cellular uptake of 75 nm diameter citrate stabilized silver NPs (Ag 75 Cit) into an individual human macrophage derived from monocytic THP-1 cells using a FIB/SEM slice and view approach. Cells were treated with 10 μg/ml for 24 h. We investigated a single cell and found in total 3138 ± 722 silver NPs inside this cell. Most of the silver NPs were located in large agglomerates, only a few were found in clusters of fewer than five NPs. Furthermore, we cross-checked our results by using inductively coupled plasma mass spectrometry and could confirm the FIB/SEM results. Our approach based on FIB/SEM slice and view is currently the only one that allows the quantification of the absolute dose of silver NPs in individual cells and at the same time to assess their intracellular distribution at high resolution. We therefore propose to use FIB/SEM slice and view to systematically analyse the cellular uptake of various NPs as a function of size, concentration and incubation time.
Xu, Yin; Zheng, Yong; Rahman, Qazi
2017-03-01
Previous studies have indicated that viewing sexually explicit media (SEM) might be associated with sexual risk behaviors in men who have sex with men (MSM). However, most prior research has not explored this association cross-culturally or the potential influence that important covariates might have on the association. To explore the association between self-reports of viewing SEM depicting various sexual risk behaviors and engagement in sexual risk behaviors after controlling for relevant covariates in MSM in China. Three hundred fourteen Chinese MSM participated in a web-based survey. SEM consumption, sexual risk behavior, and measurements of covariates. SEM consumption was frequent in MSM in China. Viewing a larger proportion of SEM depicting sexual risk behaviors was associated with a larger number of regular partners with whom MSM reported engaging in sexual risk behaviors, but not with the number of casual partners, after controlling for covariates. HIV-related knowledge and seeking male sex partners were associated with the number of regular partners with whom MSM had engaged in sexual risk behaviors. Seeking sexual sensation, HIV-related knowledge, and seeking male sex partners were associated with the number of casual partners with whom MSM had engaged in sexual risk behaviors. Future research exploring the relation between SEM use and sexual health risk behaviors should consider theoretically important psychological and behavioral covariates. Xu Y, Zheng Y, Rahman Q. The Relationship Between Self-Reported Sexually Explicit Media Consumption and Sexual Risk Behaviors Among Men Who Have Sex With Men in China. J Sex Med 2017;14:357-365. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin
2016-01-01
Background Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. Objective The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. Methods We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Results Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Conclusions Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months. PMID:28507752
Nam, Hyeong Seok; Kang, Dae Hwan; Kim, Hyung Wook; Choi, Cheol Woong; Park, Su Bum; Kim, Su Jin; Ryu, Dae Gon
2017-01-01
AIM To evaluate the safety and efficacy of limited endoscopic sphincterotomy (ES) before placement of self-expandable metal stent (SEMS). METHODS This was a retrospective analysis of 244 consecutive patients with unresectable malignant biliary obstruction, who underwent placement of SEMSs following limited ES from December 2008 to February 2015. The diagnosis of malignant biliary obstruction and assessment of patient eligibility for the study was established by a combination of clinical findings, laboratory investigations, imaging and pathological results. All patients were monitored in the hospital for at least 24 h following endoscopic retrograde cholangio pancreatography (ERCP). The incidence of immediate or early post-ERCP complications such as post-ERCP pancreatitis (PEP) and bleeding related to limited ES were considered as primary outcomes. Also, characteristics and complications according to the cancer type were classified. RESULTS Among the 244 patients included, the underlying diagnosis was cholangiocarcinoma in 118 patients, pancreatic cancer in 79, and non-pancreatic or non-biliary malignancies in the remaining 47 patients. Early post-ERCP complications occurred in 9 patients (3.7%), with PEP in 7 patients (2.9%; mild, 6; moderate, 1) and mild bleeding in 2 patients (0.8%). There was no significant association between the incidence of post-ERCP complications and the type of malignancy (cholangiocarcinoma vs pancreatic cancer vs others, P = 0.696) or the type of SEMS used (uncovered vs covered, P = 1.000). Patients who had more than one SEMS placed at the first instance were at a significantly higher risk of post-ERCP complications (one SEMS vs two SEMS, P = 0.031). No other factors were predictive of post-ERCP complications. CONCLUSION Limited ES is feasible and safe, and effectively facilitates the placement of SEMS, without any significant risk of PEP or severe bleeding. PMID:28321164
2013-01-01
Background Scanning electron microscopy (SEM) has been used for high-resolution imaging of plant cell surfaces for many decades. Most SEM imaging employs the secondary electron detector under high vacuum to provide pseudo-3D images of plant organs and especially of surface structures such as trichomes and stomatal guard cells; these samples generally have to be metal-coated to avoid charging artefacts. Variable pressure-SEM allows examination of uncoated tissues, and provides a flexible range of options for imaging, either with a secondary electron detector or backscattered electron detector. In one application, we used the backscattered electron detector under low vacuum conditions to collect images of uncoated barley leaf tissue followed by simple quantification of cell areas. Results Here, we outline methods for backscattered electron imaging of a variety of plant tissues with particular focus on collecting images for quantification of cell size and shape. We demonstrate the advantages of this technique over other methods to obtain high contrast cell outlines, and define a set of parameters for imaging Arabidopsis thaliana leaf epidermal cells together with a simple image analysis protocol. We also show how to vary parameters such as accelerating voltage and chamber pressure to optimise imaging in a range of other plant tissues. Conclusions Backscattered electron imaging of uncoated plant tissue allows acquisition of images showing details of plant morphology together with images of high contrast cell outlines suitable for semi-automated image analysis. The method is easily adaptable to many types of tissue and suitable for any laboratory with standard SEM preparation equipment and a variable-pressure-SEM or tabletop SEM. PMID:24135233
Harrow, Jeffrey John; Mayrovitz, Harvey N.
2014-01-01
Objective Characterization of a non-invasive method of quantifying subepidermal moisture (SEM) surrounding stages III and IV pressure ulcers (PrUs) in spinal cord injury (SCI). Design Prospective, single-visit, single-rater, observational study, using repeated-measures analysis. Method Setting-inpatient units of one VA SCI Center. Participants Convenience sample of 16 subjects with SCI with stage III or IV PrUs over sacrum or ischium. Interventions Measurement with the MoistureMeter-D, a hand-held device using 300 MHz electromagnetic waves. Outcome measures Dielectric constant, a dimensionless number which increases with the moisture content. Each subject had a PrU site and a control site. Measurements were made at each site, on intact skin, at four points spaced angularly around the site, in triplicate. Results (1) Short-term, single-rater relative error was 2.5%. (2) Order effect: first readings were higher than second readings in 55 of 64 measurement sets. Order effect was significant for control sites (P < 0.0001) but not for PrU sites. (3) Angular effect: SEM varied by angle at the PrU sites (P < 0.01); 12 o'clock position the highest and 6 o'clock the lowest. (4) Ability to differentiate PrUs from intact skin: SEM at PrU sites was greater by 9.0% than control sites (P < 0.05). (5) Site effect: SEM was higher at sacral locations than ischial at control sites by 20% (P < 0.005). Conclusions SEM differentiates PrUs from intact skin. Future study designs must take into account order, angular, and site effects on this measure. This information will inform designers of future studies of SEM in healing of PrUs. PMID:25398030
Neural Network for Nanoscience Scanning Electron Microscope Image Recognition.
Modarres, Mohammad Hadi; Aversa, Rossella; Cozzini, Stefano; Ciancio, Regina; Leto, Angelo; Brandino, Giuseppe Piero
2017-10-16
In this paper we applied transfer learning techniques for image recognition, automatic categorization, and labeling of nanoscience images obtained by scanning electron microscope (SEM). Roughly 20,000 SEM images were manually classified into 10 categories to form a labeled training set, which can be used as a reference set for future applications of deep learning enhanced algorithms in the nanoscience domain. The categories chosen spanned the range of 0-Dimensional (0D) objects such as particles, 1D nanowires and fibres, 2D films and coated surfaces, and 3D patterned surfaces such as pillars. The training set was used to retrain on the SEM dataset and to compare many convolutional neural network models (Inception-v3, Inception-v4, ResNet). We obtained compatible results by performing a feature extraction of the different models on the same dataset. We performed additional analysis of the classifier on a second test set to further investigate the results both on particular cases and from a statistical point of view. Our algorithm was able to successfully classify around 90% of a test dataset consisting of SEM images, while reduced accuracy was found in the case of images at the boundary between two categories or containing elements of multiple categories. In these cases, the image classification did not identify a predominant category with a high score. We used the statistical outcomes from testing to deploy a semi-automatic workflow able to classify and label images generated by the SEM. Finally, a separate training was performed to determine the volume fraction of coherently aligned nanowires in SEM images. The results were compared with what was obtained using the Local Gradient Orientation method. This example demonstrates the versatility and the potential of transfer learning to address specific tasks of interest in nanoscience applications.
Ko, Wen-Ru; Hung, Wei-Te; Chang, Hui-Chin; Lin, Long-Yau
2014-03-01
The study was designed to investigate the frequency of misusing standard error of the mean (SEM) in place of standard deviation (SD) to describe study samples in four selected journals published in 2011. Citation counts of articles and the relationship between the misuse rate and impact factor, immediacy index, or cited half-life were also evaluated. All original articles in the four selected journals published in 2011 were searched for descriptive statistics reporting with either mean ± SD or mean ± SEM. The impact factor, immediacy index, and cited half-life of the journals were gathered from Journal Citation Reports Science edition 2011. Scopus was used to search for citations of individual articles. The difference in citation counts between the SD group and SEM group was tested by the Mann-Whitney U test. The relationship between the misuse rate and impact factor, immediacy index, or cited half-life was also evaluated. The frequency of inappropriate reporting of SEM was 13.60% for all four journals. For individual journals, the misuse rate was from 2.9% in Acta Obstetricia et Gynecologica Scandinavica to 22.68% in American Journal of Obstetrics & Gynecology. Articles using SEM were cited more frequently than those using SD (p = 0.025). An approximate positive correlation between the misuse rate and cited half-life was observed. Inappropriate reporting of SEM is common in medical journals. Authors of biomedical papers should be responsible for maintaining an integrated statistical presentation because valuable articles are in danger of being wasted through the misuse of statistics. Copyright © 2014. Published by Elsevier B.V.
Nam, Hyeong Seok; Kang, Dae Hwan; Kim, Hyung Wook; Choi, Cheol Woong; Park, Su Bum; Kim, Su Jin; Ryu, Dae Gon
2017-03-07
To evaluate the safety and efficacy of limited endoscopic sphincterotomy (ES) before placement of self-expandable metal stent (SEMS). This was a retrospective analysis of 244 consecutive patients with unresectable malignant biliary obstruction, who underwent placement of SEMSs following limited ES from December 2008 to February 2015. The diagnosis of malignant biliary obstruction and assessment of patient eligibility for the study was established by a combination of clinical findings, laboratory investigations, imaging and pathological results. All patients were monitored in the hospital for at least 24 h following endoscopic retrograde cholangio pancreatography (ERCP). The incidence of immediate or early post-ERCP complications such as post-ERCP pancreatitis (PEP) and bleeding related to limited ES were considered as primary outcomes. Also, characteristics and complications according to the cancer type were classified. Among the 244 patients included, the underlying diagnosis was cholangiocarcinoma in 118 patients, pancreatic cancer in 79, and non-pancreatic or non-biliary malignancies in the remaining 47 patients. Early post-ERCP complications occurred in 9 patients (3.7%), with PEP in 7 patients (2.9%; mild, 6; moderate, 1) and mild bleeding in 2 patients (0.8%). There was no significant association between the incidence of post-ERCP complications and the type of malignancy (cholangiocarcinoma vs pancreatic cancer vs others, P = 0.696) or the type of SEMS used (uncovered vs covered, P = 1.000). Patients who had more than one SEMS placed at the first instance were at a significantly higher risk of post-ERCP complications (one SEMS vs two SEMS, P = 0.031). No other factors were predictive of post-ERCP complications. Limited ES is feasible and safe, and effectively facilitates the placement of SEMS, without any significant risk of PEP or severe bleeding.
Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin; Caca, Karel
2017-04-01
Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months.
Ohno, Shotaro; Takahashi, Kana; Inoue, Aimi; Takada, Koki; Ishihara, Yoshiaki; Tanigawa, Masaru; Hirao, Kazuki
2017-12-01
This study aims to examine the smallest detectable change (SDC) and test-retest reliability of the Center for Epidemiologic Studies Depression Scale (CES-D), General Self-Efficacy Scale (GSES), and 12-item General Health Questionnaire (GHQ-12). We tested 154 young adults at baseline and 2 weeks later. We calculated the intra-class correlation coefficients (ICCs) for test-retest reliability with a two-way random effects model for agreement. We then calculated the standard error of measurement (SEM) for agreement using the ICC formula. The SEM for agreement was used to calculate SDC values at the individual level (SDC ind ) and group level (SDC group ). The study participants included 137 young adults. The ICCs for all self-reported outcome measurement scales exceeded 0.70. The SEM of CES-D was 3.64, leading to an SDC ind of 10.10 points and SDC group of 0.86 points. The SEM of GSES was 1.56, leading to an SDC ind of 4.33 points and SDC group of 0.37 points. The SEM of GHQ-12 with bimodal scoring was 1.47, leading to an SDC ind of 4.06 points and SDC group of 0.35 points. The SEM of GHQ-12 with Likert scoring was 2.44, leading to an SDC ind of 6.76 points and SDC group of 0.58 points. To confirm that the change was not a result of measurement error, a score of self-reported outcome measurement scales would need to change by an amount greater than these SDC values. This has important implications for clinicians and epidemiologists when assessing outcomes. © 2017 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuipers, Jeroen; Boer, Pascal de; Giepmans, Ben N.G., E-mail: b.n.g.giepmans@umcg.nl
Scanning electron microscopy (SEM) is increasing its application in life sciences for electron density measurements of ultrathin sections. These are traditionally analyzed with transmission electron microscopy (TEM); by most labs, SEM analysis still is associated with surface imaging only. Here we report several advantages of SEM for thin sections over TEM, both for structural inspection, as well as analyzing immuno-targeted labels such as quantum dots (QDs) and gold, where we find that QD-labeling is ten times more efficient than gold-labeling. Furthermore, we find that omitting post-staining with uranyl and lead leads to QDs readily detectable over the ultrastructure, but undermore » these conditions ultrastructural contrast was even almost invisible in TEM examination. Importantly, imaging in SEM with STEM detection leads to both outstanding QDs and ultrastructural contrast. STEM imaging is superior over back-scattered electron imaging of these non-contrasted samples, whereas secondary electron detection cannot be used at all. We conclude that examination of ultrathin sections by SEM, which may be immunolabeled with QDs, will allow rapid and straightforward analysis of large fields with more efficient labeling than can be achieved with immunogold. The large fields of view routinely achieved with SEM, but not with TEM, allows straightforward raw data sharing using virtual microscopy, also known as nanotomy when this concerns EM data in the life sciences. - Highlights: • High resolution and large fields of view via nanotomy or virtual microscopy. • Highly relevant for EM‐datasets where information density is high. • Sample preparation with low contrast good for STEM, not TEM. • Quantum dots now stand out in STEM‐based detection. • 10 Times more efficient labeling with quantum dots compared to gold.« less
The combination of scanning electron and scanning probe microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sapozhnikov, I. D.; Gorbenko, O. M., E-mail: gorolga64@gmail.com; Felshtyn, M. L.
2016-06-17
We suggest the SPM module to combine SEM and SPM methods for studying surfaces. The module is based on the original mechanical moving and scanning system. The examples of studies of the steel surface microstructure in both SEM and SPM modes are presented.
Scanning electron microscopy of bone: instrument, specimen, and issues.
Boyde, A; Jones, S J
1996-02-01
There are many ways available now to maximise and analyse the information that can be obtained on the structure and constitution of bone using SEM. This paper considers a range of methods and the problems that arise relating to instrumentation and methodology as they apply to the use of SEM in the study of bone. In addition to the review content, some novel technical approaches to the SEM of bone are considered here for the first time; these include low kV imaging for the detection of new surface bone packets (and residual demineralized matrix after resorption), low kV BSE imaging of uncoated, embedded, and unembedded samples, environmental SEM for the study of wet tissue, low distortion, very low magnification imaging for the study of cancellous bone architecture, the use of multiple detectors for fast electrons in improving the imaging of porous samples, and high resolution, low voltage imaging for the study of collagen degradation during bone resorption.
Carotene location in processed food samples measured by cryo In-SEM Raman.
Lopez-Sanchez, Patricia; Schumm, Stephan; Pudney, Paul D A; Hazekamp, Johan
2011-09-21
Cryo In-SEM Raman has been used for the first time to localise carotene compounds in a food matrix. Raman spectra of lycopene and β-carotene have been obtained from sampling oil droplets and plant cell structures visualised with cryo-SEM in tomato and carrot based emulsions containing 5% oil. It was possible to identify the carotenoids in both the oil droplets and the cell walls. Furthermore our results gave some indication that the carotenoids were in the non-crystalline state. It has been suggested that a higher amount of carotenes solubilised into the oil phase of the food matrix would lead to a higher bioaccessibility, thus understanding the effect of processing conditions on micronutrients distribution in a food matrix might help the design of plant based food products with a better nutritional quality. This shows improved structural characterisation of the cryo-SEM with the molecular sensitivity of Raman spectroscopy as a promising approach for complex biological problems.
Kanturski, Mariusz; Karcz, Jagna; Wieczorek, Karina
2015-09-01
Scanning electron microscopy (SEM) methods were used for the first time to elucidate the external morphology of the European species of the genus Eulachnus (Hemiptera: Aphididae: Lachninae), a representative genus of the conifer-feeding aphids tribe Eulachnini. We examined and compared the external morphology of apterous and alate viviparous females from the parthenogenetic generation as well as oviparous females and alate males belonging to the sexual generation. FE-SEM images based on HMDS and cryo-SEM preparation techniques revealed better image quality than the CPD technique in regard to surface tension and morphological signs of cell deteriorations (i.e., existence of depressions, drying artifacts and membrane blebs). Three morphologically different species groups "agilis", "brevipilosus" and "cembrae" were proposed due to the differences in head, antennae, legs and dorsal chaetotaxy as well as dorsal sclerotization. The most characteristic features and differences of representatives of these groups are presented and discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Image contrast enhancement of Ni/YSZ anode during the slice-and-view process in FIB-SEM.
Liu, Shu-Sheng; Takayama, Akiko; Matsumura, Syo; Koyama, Michihisa
2016-03-01
Focused ion beam-scanning electron microscopy (FIB-SEM) is a widely used and easily operational equipment for three-dimensional reconstruction with flexible analysis volume. It has been using successfully and increasingly in the field of solid oxide fuel cell. However, the phase contrast of the SEM images is indistinct in many cases, which will bring difficulties to the image processing. Herein, the phase contrast of a conventional Ni/yttria stabilized zirconia anode is tuned in an FIB-SEM with In-Lens secondary electron (SE) and backscattered electron detectors. Two accessories, tungsten probe and carbon nozzle, are inserted during the observation. The former has no influence on the contrast. When the carbon nozzle is inserted, best and distinct contrast can be obtained by In-Lens SE detector. This method is novel for contrast enhancement. Phase segmentation of the image can be automatically performed. The related mechanism for different images is discussed. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Enhanced FIB-SEM systems for large-volume 3D imaging
Xu, C Shan; Hayworth, Kenneth J; Lu, Zhiyuan; Grob, Patricia; Hassan, Ahmed M; García-Cerdán, José G; Niyogi, Krishna K; Nogales, Eva; Weinberg, Richard J; Hess, Harald F
2017-01-01
Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 106 µm3. These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology. DOI: http://dx.doi.org/10.7554/eLife.25916.001 PMID:28500755
Morphological Comparison of U3O8 Ore Concentrates from Canada Key Lake and Namibia Sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwartz, Daniel S.; Tandon, Lav; Martinez, Patrick Thomas
Uranium ore concentrates from two different sources were examined using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The ore powders are referred to as Namibia (id. no. 90036, LIMS id. no. 18775) and Canada Key Lake (id. no. 90019, LIMS id. no. 18774). Earlier work identified the ores as the U₃O₈ phase of uranium oxide using x-ray diffraction. Both sets of powders were in the form of dark brown to black powder fines. However, the Canada Key Lake concentrates contained larger chunks of material on the millimeter scale that were easily visible to the unaided eye. The powdersmore » were mounted for SEM examination by hand dispersing a small amount onto conductive sticky tape. Two types of applicators were used and compared: a fine-tipped spatula and a foam-tipped applicator. The sticky tape was on a standard SEM “tee” mount, which was tapped to remove loose contamination before being inserted into the SEM.« less
The capability of lithography simulation based on MVM-SEM® system
NASA Astrophysics Data System (ADS)
Yoshikawa, Shingo; Fujii, Nobuaki; Kanno, Koichi; Imai, Hidemichi; Hayano, Katsuya; Miyashita, Hiroyuki; Shida, Soichi; Murakawa, Tsutomu; Kuribara, Masayuki; Matsumoto, Jun; Nakamura, Takayuki; Matsushita, Shohei; Hara, Daisuke; Pang, Linyong
2015-10-01
The 1Xnm technology node lithography is using SMO-ILT, NTD or more complex pattern. Therefore in mask defect inspection, defect verification becomes more difficult because many nuisance defects are detected in aggressive mask feature. One key Technology of mask manufacture is defect verification to use aerial image simulator or other printability simulation. AIMS™ Technology is excellent correlation for the wafer and standards tool for defect verification however it is difficult for verification over hundred numbers or more. We reported capability of defect verification based on lithography simulation with a SEM system that architecture and software is excellent correlation for simple line and space.[1] In this paper, we use a SEM system for the next generation combined with a lithography simulation tool for SMO-ILT, NTD and other complex pattern lithography. Furthermore we will use three dimension (3D) lithography simulation based on Multi Vision Metrology SEM system. Finally, we will confirm the performance of the 2D and 3D lithography simulation based on SEM system for a photomask verification.
Framework for SEM contour analysis
NASA Astrophysics Data System (ADS)
Schneider, L.; Farys, V.; Serret, E.; Fenouillet-Beranger, C.
2017-03-01
SEM images provide valuable information about patterning capability. Geometrical properties such as Critical Dimension (CD) can be extracted from them and are used to calibrate OPC models, thus making OPC more robust and reliable. However, there is currently a shortage of appropriate metrology tools to inspect complex two-dimensional patterns in the same way as one would work with simple one-dimensional patterns. In this article we present a full framework for the analysis of SEM images. It has been proven to be fast, reliable and robust for every type of structure, and particularly for two-dimensional structures. To achieve this result, several innovative solutions have been developed and will be presented in the following pages. Firstly, we will present a new noise filter which is used to reduce noise on SEM images, followed by an efficient topography identifier, and finally we will describe the use of a topological skeleton as a measurement tool that can extend CD measurements on all kinds of patterns.
Automated SEM and TEM sample preparation applied to copper/low k materials
NASA Astrophysics Data System (ADS)
Reyes, R.; Shaapur, F.; Griffiths, D.; Diebold, A. C.; Foran, B.; Raz, E.
2001-01-01
We describe the use of automated microcleaving for preparation of both SEM and TEM samples as done by SELA's new MC500 and TEMstation tools. The MC500 is an automated microcleaving tool that is capable of producing cleaves with 0.25 μm accuracy resulting in SEM-ready samples. The TEMstation is capable of taking a sample output from the MC500 (or from SELA's earlier MC200 tool) and producing a FIB ready slice of 25±5 μm, mounted on a TEM-washer and ready for FIB thinning to electron transparency for TEM analysis. The materials selected for the tool set evaluation mainly included the Cu/TaN/HOSP low-k system. The paper is divided into three sections, experimental approach, SEM preparation and analysis of HOSP low-k, and TEM preparation and analysis of Cu/TaN/HOSP low-k samples. For the samples discussed, data is presented to show the quality of preparation provided by these new automated tools.
Constructing a Graph Database for Semantic Literature-Based Discovery.
Hristovski, Dimitar; Kastrin, Andrej; Dinevski, Dejan; Rindflesch, Thomas C
2015-01-01
Literature-based discovery (LBD) generates discoveries, or hypotheses, by combining what is already known in the literature. Potential discoveries have the form of relations between biomedical concepts; for example, a drug may be determined to treat a disease other than the one for which it was intended. LBD views the knowledge in a domain as a network; a set of concepts along with the relations between them. As a starting point, we used SemMedDB, a database of semantic relations between biomedical concepts extracted with SemRep from Medline. SemMedDB is distributed as a MySQL relational database, which has some problems when dealing with network data. We transformed and uploaded SemMedDB into the Neo4j graph database, and implemented the basic LBD discovery algorithms with the Cypher query language. We conclude that storing the data needed for semantic LBD is more natural in a graph database. Also, implementing LBD discovery algorithms is conceptually simpler with a graph query language when compared with standard SQL.
Contact detection for nanomanipulation in a scanning electron microscope.
Ru, Changhai; To, Steve
2012-07-01
Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000× magnification while inducing little end-effector damage. Copyright © 2012 Elsevier B.V. All rights reserved.
Enhanced FIB-SEM systems for large-volume 3D imaging
Xu, C. Shan; Hayworth, Kenneth J.; Lu, Zhiyuan; ...
2017-05-13
Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 ?m 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processesmore » and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.« less
Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns
NASA Astrophysics Data System (ADS)
Trifkovic, B.; Budak, I.; Todorovic, A.; Hodolic, J.; Puskar, T.; Jevremovic, D.; Vukelic, D.
2012-01-01
The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.
Multi-signal FIB/SEM tomography
NASA Astrophysics Data System (ADS)
Giannuzzi, Lucille A.
2012-06-01
Focused ion beam (FIB) milling coupled with scanning electron microscopy (SEM) on the same platform enables 3D microstructural analysis of structures using FIB for serial sectioning and SEM for imaging. Since FIB milling is a destructive technique, the acquisition of multiple signals from each slice is desirable. The feasibility of collecting both an inlens backscattered electron (BSE) signal and an inlens secondary electron (SE) simultaneously from a single scan of the electron beam from each FIB slice is demonstrated. The simultaneous acquisition of two different SE signals from two different detectors (inlens vs. Everhart-Thornley (ET) detector) is also possible. Obtaining multiple signals from each FIB slice with one scan increases the acquisition throughput. In addition, optimization of microstructural and morphological information from the target is achieved using multi-signals. Examples of multi-signal FIB/SEM tomography from a dental implant will be provided where both material contrast from the bone/ceramic coating/Ti substrate phases and porosity in the ceramic coating will be characterized.
Safety in the SEM laboratory--1981 update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bance, G.N.; Barber, V.C.; Sholdice, J.A.
1981-01-01
The article reviews recent information on hazards as they relate to safety in SEM laboratories. The first section lists the safety equipment that should be available in a SEM laboratory. Flammable and combustible liquids are discussed, and particular warnings are given concerning the fire and explosion risks associated with diethyl ether and diisopropyl ether. The possible hazards associated with electrical equipment, and the risk of X-ray emissions from EM's are briefly outlined. The hazards associated with acute and chronic toxicity of chemicals used in the EM laboratory are discussed. The need to reduce exposure to a growing list of recognizablemore » hazardous chemicals is emphasized. This reduction can be accomplished by more extensive use of functioning fume hoods, and the use of more appropriate and effective protective gloves. Allergies and the hazards of dangerous pathogens in the SEM laboratory are discussed. The explosion and other hazards associated with cryogens, vacuum evaporators, critical point dryers, and compressed gas cylinders are emphasized.« less
Hald, Gert Martin; Smolenski, Derek; Rosser, B R Simon
2013-03-01
Researchers have proposed that consumption of Sexually Explicit Media (SEM) may not only adversely influence sexual attitudes and behaviors of Men Who Have Sex with Men (MSM) but (also) play a positive role in the development and sexual education of MSM, be a major source of sexual information for MSM, and provide validation, understanding, and confirmation of MSM's sexual orientation. However, such claims are in urgent need of empirical validation as is the development of psychometrically sound and easily implemented instruments able to reliably assist such validations. To investigate how MSM who consume SEM self-perceive the impact of SEM on their sexually-transmitted-infections-related sexual risk behaviors (i.e., anal intercourse), sexual knowledge, enjoyment of sex, interest in sex, attitudes toward sex, and understanding of their sexual orientation. Further, to provide a thorough psychometric validation of a reduced and reworked version of the Pornography Consumption Effects Scale (PCES). Main Outcome Measure. A revised version of the PCES by Hald and Malamuth. Online cross-sectional survey study of 1,333 US adult Men Who Have Sex with Men. This study found that 97% of MSM reported positive effects of SEM consumption on their sexual knowledge, enjoyment of and interest in sex, attitudes toward sex, and understanding of their sexual orientation. Only 3% reported any negative effects of their SEM consumption. SEM consumption was found to significantly increase consumers' interest in having protected anal intercourse while not significantly influencing their interests in having unprotected anal intercourse. The revised version of the PCES showed excellent psychometric performance. The study found that MSM generally report positive effects of their consumption of sexually explicit materials in areas related to their sexual knowledge, attitudes, behaviors, and orientation. This finding could have important implications for the sexual health and well-being of MSM by suggesting that SEM-based education and intervention might hold considerable overall health potential for MSM. © 2012 International Society for Sexual Medicine.
Nagy, Péter; Thomas, Sonia; Markó, Orsolya; Juhász, Jutka
2013-03-01
In many arid countries, dromedaries play an important role as a milk source in rural areas. However, the milk and meat production potential of this species is not well understood and documented. A large-scale camel dairy farm was established in 2006 in the United Arab Emirates. This study summarises the most important data on milk production, raw milk quality and reproductive efficiency collected on this farm during the first three years of operation. The average daily milk production, the mean length of lactation and the mean total milk production per lactation of 174 dromedaries were 6.0 ± 0.12 kg (± SEM), 586 ± 11.0 days (± SEM) and 3314 ± 98.5 kg (± SEM), respectively. The lactation curve reached its peak during the 4th month after parturition (mean ± SEM, 8.9 ± 0.04 kg), then it declined gradually, falling to 50% of the maximum by the 16th month postpartum (mean ± SEM, 4.3 ± 0.06 kg). Milking three times a day did not increase daily milk production compared to two times milking. Mean total viable bacterial count (TVC) and mean somatic cell count (SCC, ± SEM) of bulk raw camel milk were 4,403 ± 94 CFU/cm3 and 392,602 ± 5,999 cells/cm3 for a one-year period, respectively. There was a significant difference among months (P < 0.001). Coliform count was < 10 CFU/cm3 in most cases (96.5%). The average (± SEM) fat, protein, lactose, total solids (TS) and solid-non-fat (SNF) concentrations of individual milk samples were 2.51 ± 0.03%, 2.60 ± 0.01%, 4.03 ± 0.03%, 9.98 ± 0.03% and 7.56 ± 0.03%, respectively. Lactation period, average daily milk production and morning vs. evening milking significantly influenced milk chemical composition. For the 470 camels in the breeding programme, end-of-season pregnancy rate and birth rate were 87.0% and 82.6%, respectively, after natural mating. We have demonstrated that sustainable milk production is possible from a traditional species, the dromedary camel, under an intensive management system.
GPU accelerated Monte-Carlo simulation of SEM images for metrology
NASA Astrophysics Data System (ADS)
Verduin, T.; Lokhorst, S. R.; Hagen, C. W.
2016-03-01
In this work we address the computation times of numerical studies in dimensional metrology. In particular, full Monte-Carlo simulation programs for scanning electron microscopy (SEM) image acquisition are known to be notoriously slow. Our quest in reducing the computation time of SEM image simulation has led us to investigate the use of graphics processing units (GPUs) for metrology. We have succeeded in creating a full Monte-Carlo simulation program for SEM images, which runs entirely on a GPU. The physical scattering models of this GPU simulator are identical to a previous CPU-based simulator, which includes the dielectric function model for inelastic scattering and also refinements for low-voltage SEM applications. As a case study for the performance, we considered the simulated exposure of a complex feature: an isolated silicon line with rough sidewalls located on a at silicon substrate. The surface of the rough feature is decomposed into 408 012 triangles. We have used an exposure dose of 6 mC/cm2, which corresponds to 6 553 600 primary electrons on average (Poisson distributed). We repeat the simulation for various primary electron energies, 300 eV, 500 eV, 800 eV, 1 keV, 3 keV and 5 keV. At first we run the simulation on a GeForce GTX480 from NVIDIA. The very same simulation is duplicated on our CPU-based program, for which we have used an Intel Xeon X5650. Apart from statistics in the simulation, no difference is found between the CPU and GPU simulated results. The GTX480 generates the images (depending on the primary electron energy) 350 to 425 times faster than a single threaded Intel X5650 CPU. Although this is a tremendous speedup, we actually have not reached the maximum throughput because of the limited amount of available memory on the GTX480. Nevertheless, the speedup enables the fast acquisition of simulated SEM images for metrology. We now have the potential to investigate case studies in CD-SEM metrology, which otherwise would take unreasonable amounts of computation time.
NASA Astrophysics Data System (ADS)
Conny, J. M.; Collins, S. M.; Anderson, I.; Herzing, A.
2010-12-01
Carbon-containing atmospheric particles may either absorb solar or outgoing long-wave radiation or scatter solar radiation, and thus, affect Earth’s radiative balance in multiple ways. Light-absorbing carbon that is common in urban air particles such as industrial coke dust, road dust, and diesel soot, often exists in the same particle with other phases that contain, for example, aluminum, calcium, iron, and sulfur. While the optical properties of atmospheric particles in general depend on overall particle size and shape, the inhomogeneity of chemical phases within internally-mixed particles may also greatly affect particle optical properties. In this study, a series of microscopic approaches were used to identify individual light-absorbing coarse-mode particles and to assess their interior structure and composition. Particle samples were collected in 2004 from one of the U.S. EPA’s Los Angeles Particulate Matter Supersites, and were likely affected substantially by road dust and construction dust. First, bright-field and dark-field light microscopy and computer-controlled scanning electron microscopy (SEM) with energy-dispersive x-ray spectroscopy (EDX) were used to distinguish predominantly light-absorbing carbonaceous particles from other particle types such as mineral dust, sea salt, and brake wear. Second, high-resolution SEM-EDX elemental mapping of individual carbonaceous particles was used to select particles with additional elemental phases that exhibited spatial inhomogeneity. Third, focused ion-beam SEM (FIB-SEM) with EDX was used to slice through selected particles to expose interior surfaces and to determine the spatial distribution of element phases throughout the particles. Fourth, study of the interior phases of a particle was augmented by the transmission electron microscopy (TEM) of a thin section of the particle prepared by FIB-SEM. Here, electron energy loss spectroscopy with TEM was used to study chemical bonding in the carbonaceous phase. Finally, automated serial slicing and imaging in the FIB-SEM generated a stack of secondary electron images of the particles’ interior surfaces that allowed for the 3-D reconstruction of the particles, a process known as FIB tomography. Interior surface of light-absorbing carbonaceous particle from FIB-SEM analysis.
Hernández-Crespo, Carmen; Martín, Miguel
2013-11-01
Lake Albufera is one of the most eutrophic bodies of water in Spain due to point and diffuse pollution over past decades, and its sediments are likely to be anoxic because of high organic matter flux. Hence, sulphides can play an important role in limiting the mobility of heavy metals. This study aimed to study the vertical variation of acid volatile sulphide (AVS) and simultaneously extracted metals (SEM) in sediment cores collected from Lake Albufera; other sediment characteristics, such as organic matter, biochemical oxygen, demand or total metals, were also studied. Three sites were selected, and four sampling campaigns were performed to study spatial and temporal variation as well as to obtain information regarding historical variation in the composition of sediments. AVS and SEM were analysed by the purge-and-trap method. The vertical distribution of AVS and SEM varied depending on the sampling site-concentrations of AVS and SEM were higher at sites close to mouths of inflowing channels. A decreasing trend of AVS has been found at these sites over time: In the two first samplings, AVS increased with depth reaching maximum concentrations of 40 and 21 μmol g(-1), but from then on AVS were lower and decreased with depth. SEM decreased with depth from 3 μmol g(-1) in surface layers to approximately 1 μmol g(-1) at deeper segments at these sites. However, the central site was more uniform with respect to depth as well as with time; it presented lower values of SEM and AVS (mean 0.9 and 2.0 μmol g(-1) respectively), and the maximum value of AVS (7 μmol g(-1)) was found at the top layer (0-3 cm). According to the (SEM-AVS)/fOC approach, every site, and throughout the cores, can be classified as containing nontoxic metals because the values were <130 μmol g(-1).
Three dimensional rock microstructures: insights from FIB-SEM tomography
NASA Astrophysics Data System (ADS)
Drury, Martyn; Pennock, Gill; de Winter, Matthijs
2016-04-01
Most studies of rock microstructures investigate two-dimensional sections or thin slices of three dimensional grain structures. With advances of X-ray and electron tomography methods the 3-D microstructure can be(relatively) routinely investigated on scales from a few microns to cm. 3D studies are needed to investigate the connectivity of microstructures and to test the assumptions we use to calculate 3D properties from 2D sections. We have used FIB-SEM tomography to study the topology of melts in synthetic olivine rocks, 3D crystal growth microstructures, pore networks and subgrain structures. The technique uses a focused ion beam to make serial sections with a spacing of tens to hundreds of nanometers. Each section is then imaged or mapped using the electron beam. The 3D geometry of grains and subgrains can be investigated using orientation contrast or EBSD mapping. FIB-SEM tomography of rocks and minerals can be limited by charging of the uncoated surfaces exposed by the ion beam. The newest generation of FIB-SEMs have much improved low voltage imaging capability allowing high resolution charge free imaging. Low kV FIB-SEM tomography is now widely used to study the connectivity of pore networks. In-situ fluids can also be studied using cryo-FIB-SEM on frozen samples, although special freezing techniques are needed to avoid artifacts produced by ice crystallization. FIB-SEM tomography is complementary, in terms of spatial resolution and sampled volume, to TEM tomography and X-ray tomography, and the combination of these methods can cover a wide range of scales. Our studies on melt topology in synthetic olivine rocks with a high melt content show that many grain boundaries are wetted by nanometre scale melt layers that are too thin to resolve by X-ray tomography. A variety of melt layer geometries occur consistent with several mechanisms of melt layer formation. The nature of melt geometries along triple line junctions and quadruple points can be resolved. Quadruple point junctions between four grains cannot be investigated in 2D studies. 3D microstructural studies suggest that triple lines and quadruple points are important sites for the initiation of recrystallization, reaction and fracture.
Method for observation of deembedded sections of fish gonad by scanning electron microscopy
NASA Astrophysics Data System (ADS)
Mao, Lian-Ju
2000-09-01
This article reports a method for examining the intracellular structure of fish gonads using a scanning electron microscope(SEM). The specimen preparation procedure is similar to that for transmission electron microscopy wherein samples cut into semi-thin sections are fixed and embedded in plastic. The embedment matrix was removed by solvents. Risen-free specimens could be observed by SEM. The morphology of matured sperms in the gonad was very clear, and the oocyte internal structures appeared in three-dimensional images. Spheroidal nucleoli and yolk vesicles and several bundles of filaments adhered on the nucleoli could be viewed by SEM for the first time.
Iantaffi, Alex; Wilkerson, J Michael; Grey, Jeremy A; Rosser, B R Simon
2015-01-01
Sexually explicit media (SEM) have been used in HIV-prevention advertisements to engage men who have sex with men (MSM) and to communicate content. These advertisements exist within larger discourses, including a dominant heteronormative culture and a growing homonormative culture. Cognizant of these hegemonic cultures, this analysis examined the acceptable level of sexual explicitness in prevention advertisements. Seventy-nine MSM participated in 13 online focus groups, which were part of a larger study of SEM. Three macro themes-audience, location, and community representation-emerged from the analysis, as did the influence of homonormativity on the acceptability of SEM in HIV-prevention messages.
Automated SEM-EDS GSR Analysis for Turkish Ammunitions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cakir, Ismail; Uner, H. Bulent
2007-04-23
In this work, Automated Scanning Electron Microscopy with Energy Dispersive X-ray Spectrometry (SEM-EDS) was used to characterize 7.65 and 9mm cartridges Turkish ammunition. All samples were analyzed in a SEM Jeol JSM-5600LV equipped BSE detector and a Link ISIS 300 (EDS). A working distance of 20mm, an accelerating voltage of 20 keV and gunshot residue software was used in all analysis. Automated search resulted in a high number of particles analyzed containing gunshot residues (GSR) unique elements (PbBaSb). The obtained data about the definition of characteristic GSR particles was concordant with other studies on this topic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yashchuk, Valeriy V; Conley, Raymond; Anderson, Erik H.
We discuss the results of SEM and TEM measurements with the BPRML test samples fabricated from a BPRML (WSi2/Si with fundamental layer thickness of 3 nm) with a Dual Beam FIB (focused ion beam)/SEM technique. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-raymore » microscopes. Corresponding work with x-ray microscopes is in progress.« less
A SEM-correlation of the anatomy of the vitreous body: making visible the invisible.
Jongebloed, W L; Humalda, D; Worst, J F
1986-12-30
The naked human vitreous (sclera, iris and cornea removed) suspended in water does not reveal inner structures. After ink injection into the vitreous, the presence of different compartments and the existence of cisterns becomes evident. A concept of the internal system of cisterns is given on the basis of stereoscopic-lightmicroscopic images. An attempt is made to correlate images of the complete vitreous body, obtained with a stereo-lightmicroscope, with images of segments of cisternal walls produced with a scanning electron-microscope (SEM). A comparison is made between SEM-images of the vitreous bodies of human and rabbit eyes.
Iantaffi, Alex; Wilkerson, J. Michael; Grey, Jeremy A.; Rosser, B. R. Simon
2014-01-01
Sexually explicit media (SEM) have been used in HIV-prevention advertisements to engage men who have sex with men (MSM), and to communicate content. These advertisements exist within larger discourses, including a dominant heternormative culture, and a growing homonormative culture. Cognizant of these hegemonic cultures, this analysis examined the acceptable level of sexual explicitness in prevention advertisements. 79 MSM participated in 13 online focus groups, which were part of a larger study of SEM. Three macro-themes—audience, location and community representation—emerged from the analysis, as did the influence of homonormativity on the acceptability of SEM in HIV-prevention messages. PMID:26075485
Characterization of Polycapillary Optics in a TES Microcalorimeter EDS System Installed on an SEM
NASA Astrophysics Data System (ADS)
Takano, A.; Maehata, K.; Iyomoto, N.; Yasuda, K.; Maeno, H.; Shiiyama, K.; Tanaka, K.
2016-08-01
Energy-dispersive spectroscopic measurements are performed using a superconducting transition-edge sensor (TES) microcalorimeter mounted on a scanning electron microscope (SEM) for advanced research at Kyushu University. Because the sensitive area of the TES microcalorimeter is about 0.02~mm2, polycapillary optics is used to collect the X-rays emitted by the SEM specimen on the TES microcalorimeter. The X-ray transmission efficiency of the polycapillary optics is obtained by analyzing the X-ray energy spectra measured by the TES microcalorimeter. The obtained transmission efficiency of the polycapillary optics is reproduced by the calculated results of the simulation.
Pharmacokinetics of pancreatic polypeptide in man.
Adrian, T E; Greenberg, G R; Besterman, H S; Bloom, S R
1978-10-01
Pure bovine pancreatic polypeptide (PP) was infused into 23 healthy subjects at doses of 1, 3, and 5 pmol/kg/min over 60 minutes and plasma PP was measured by radioimmunoassay. During the infusions mean plasma levels of 203 +/- 34, 575 +/- 73, and 930 +/- 48 pmol/l respectively were achieved. Mean disappearance half time on stopping the infusion was 6.9 +/- 0.3 min (mean +/- SEM). The metabolic clearance rate was 5.1 +/- 0.2 ml/kg/min (mean +/- SEM) and the apparent volume of distribution was calculated to be 51 +/- 3 ml/kg (mean +/- SEM). This study provides for the first time pharmacokinetic data for PP in man.
Pharmacokinetics of pancreatic polypeptide in man.
Adrian, T E; Greenberg, G R; Besterman, H S; Bloom, S R
1978-01-01
Pure bovine pancreatic polypeptide (PP) was infused into 23 healthy subjects at doses of 1, 3, and 5 pmol/kg/min over 60 minutes and plasma PP was measured by radioimmunoassay. During the infusions mean plasma levels of 203 +/- 34, 575 +/- 73, and 930 +/- 48 pmol/l respectively were achieved. Mean disappearance half time on stopping the infusion was 6.9 +/- 0.3 min (mean +/- SEM). The metabolic clearance rate was 5.1 +/- 0.2 ml/kg/min (mean +/- SEM) and the apparent volume of distribution was calculated to be 51 +/- 3 ml/kg (mean +/- SEM). This study provides for the first time pharmacokinetic data for PP in man. PMID:568585
Hamai, Yoichi; Hihara, Jun; Emi, Manabu; Okita, Riki; Shimizu, Katsuhiko; Okada, Morihito
2011-04-01
We herein describe a 41-year-old man with esophageal cancer who developed three esophagorespiratory fistulas (ERFs) that were successfully treated using one esophageal and three airway stents. A self-expandable metallic stent (SEMS) was initially inserted into the esophagus to close an ERF in the right bronchus. However, two new ERFs developed in the trachea and the left main bronchus 3 months later because of pressure necrosis and penetration of the esophageal SEMS. These secondary ERFs were subsequently closed using two silicone stents, together with one SEMS in the airway. This experience suggests that appropriate stenting can control multiple and large ERFs.
Building a SEM Analytics Reporting Portfolio
ERIC Educational Resources Information Center
Goff, Jay W.; Williams, Brian G.; Kilgore, Wendy
2016-01-01
Effective strategic enrollment management (SEM) efforts require vast amounts of internal and external data to ensure that meaningful reporting and analysis systems can assist managers in decision making. A wide range of information is integral for leading effective and efficient student recruitment and retention programs. This article is designed…
ERIC Educational Resources Information Center
Barnes, Bradley; Bourke, Brian
2015-01-01
The authors advance the concept that institutional culture is a purposeful framework by which to view SEM's utility, particularly as a cultural change agent. Through the connection of seemingly independent functions of performance and behavior, implications emerge that deepen the understanding of the influence of culture on performance outcomes…
Bayesian Semiparametric Structural Equation Models with Latent Variables
ERIC Educational Resources Information Center
Yang, Mingan; Dunson, David B.
2010-01-01
Structural equation models (SEMs) with latent variables are widely useful for sparse covariance structure modeling and for inferring relationships among latent variables. Bayesian SEMs are appealing in allowing for the incorporation of prior information and in providing exact posterior distributions of unknowns, including the latent variables. In…
GUIDELINES FOR THE APPLICATION OF SEM/EDX ANALYTICAL TECHNIQUES FOR FINE AND COARSE PM SAMPLES
Scanning Electron Microscopy (SEM) coupled with Energy-Dispersive X-ray analysis (EDX) is a powerful tool in the characterization and source apportionment of environmental particulate matter (PM), providing size, chemistry, and morphology of particles as small as a few tenths ...
Recent interest in monitoring and speciation of particulate matter has led to increased application of scanning electron microscopy (SEM) coupled with energy-dispersive x-ray analysis (EDX) to individual particle analysis. SEM/EDX provides information on the size, shape, co...
Development of Intrinsically Labeled Eggs and Poultry Meat for Use in Human Metabolic Research.
van Vliet, Stephan; Beals, Joseph W; Parel, Justin T; Hanna, Christina D; Utterback, Pamela L; Dilger, Anna C; Ulanov, Alexander V; Li, Zhong; Paluska, Scott A; Moore, Daniel R; Parsons, Carl M; Burd, Nicholas A
2016-07-01
Stable isotope amino acids are regularly used as tracers to examine whole-body and muscle protein metabolism in humans. To accurately assess in vivo dietary protein digestion and absorption kinetics, the amino acid tracer is required to be incorporated within the dietary protein food source (i.e., intrinsically labeled protein). We assessed the practicality of producing eggs and poultry meat intrinsically labeled with l-[5,5,5-(2)H3]leucine through noninvasive oral tracer administration. A specifically formulated diet containing 0.52% leucine was supplemented with 0.3% l-[5,5,5-(2)H3]leucine and subsequently fed to 3 laying hens (Lohmann LSL Whites) for 55 d. On day 55, the hens were slaughtered and their meat, bones, and organs were harvested to determine tissue labeling. In Expt. 1, 2 healthy young men [mean ± SEM age: 22 ± 1.5 y; mean ± SEM body mass index (BMI; in kg/m(2)): 23.7 ± 0.5] ingested 18 g l-[5,5,5-(2)H3]leucine-labeled egg protein. In Expt. 2, 2 healthy young men (mean ± SEM age: 20.0 ± 0.0 y; mean ± SEM BMI: 26.4 ± 3.1) ingested 28 g l-[5,5,5-(2)H3]leucine-labeled poultry meat protein. Plasma samples (Expts. 1 and 2) and muscle biopsies (Expt. 1) were collected before and after labeled-food ingestion. High tracer labeling [>20 mole percent excess (MPE)] in the eggs was obtained after 7 d and maintained throughout the feeding protocol (P < 0.05). Over a 55-d period, ∼850 g egg protein (145 eggs) was produced, with a mean ± SEM tracer enrichment of 22.0 ± 0.8 MPE. Mean ± SEM l-[5,5,5-(2)H3]leucine enrichment in the meat was 9.6 ± 0.1 MPE. In Expts. 1 and 2, the consumption of labeled eggs and poultry meat protein increased plasma l-[5,5,5-(2)H3]leucine enrichment, with mean ± SEM peak values of 6.7 ± 0.1 MPE and 4.0 ± 0.9 MPE, respectively. The mean ± SEM 5-h postprandial increase in myofibrillar l-[5,5,5-(2)H3]leucine enrichment after egg ingestion in healthy young men was 0.051 ± 0.008 MPE (Expt. 1). We demonstrated the feasibility of producing intrinsically labeled eggs and poultry meat for use in human metabolic research. © 2016 American Society for Nutrition.
Group Waterpipe Tobacco Smoking Increases Smoke Toxicant Concentration.
Ramôa, Carolina P; Shihadeh, Alan; Salman, Rola; Eissenberg, Thomas
2016-05-01
Waterpipe tobacco smoking is a global health concern. Laboratory research has focused on individual waterpipe users while group use is common. This study examined user toxicant exposure and smoke toxicant yield associated with individual and group waterpipe smoking. Twenty-two pairs of waterpipe smokers used a waterpipe individually and as a dyad. Before and after smoking, blood was sampled and expired carbon monoxide (CO) measured; puff topography was recorded throughout. One participant from each pair was selected randomly and their plasma nicotine and expired air CO concentrations were compared when smoking alone to when smoking as part of a dyad. Recorded puff topography was used to machine-produce smoke that was analyzed for toxicant content. There was no difference in mean plasma nicotine concentration when an individual smoked as part of a dyad (mean = 14.9 ng/ml; standard error of the mean [SEM] = 3.0) compared to when smoking alone (mean = 10.0 ng/ml; SEM = 1.5). An individual smoking as part of as a dyad had, on average, lower CO (mean = 15.8 ppm; SEM = 2.0) compared to when smoking alone (mean= 21.3 ppm; SEM = 2.7). When two participants smoked as a dyad they took, on average, more puffs (mean = 109.8; SEM = 7.6) than a singleton smoker (mean = 77.7; SEM = 8.1) and a shorter interpuff interval (IPI; dyad mean = 23.8 seconds; SEM = 1.9; singleton mean = 40.8 seconds; SEM = 4.8). Higher concentrations of several toxicants were observed in dyad-produced smoke. Dyad smoking may increase smoke toxicant content, likely due to the dyad's shorter IPIs and greater puff number. More work is needed to understand if group waterpipe smoking alters the health risks of waterpipe tobacco smoking. This study is the first to measure toxicants in smoke generated from a waterpipe when used by a dyad. Relative to smoke generated by a singleton, dyad smoke had higher concentration of some toxicants. These differences may be attributed to differences in puffing behavior, specifically the shorter IPI and greater puff number observed in the dyad condition. Relative to singleton smokers, dyad smokers were exposed to less CO, but nicotine exposure did not differ. More work is needed to assess the health effects of inhalation of more toxicant-laden smoke during group waterpipe use. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Extended mind and after: socially extended mind and actor-network.
Kono, Tetsuya
2014-03-01
The concept of extended mind has been impressively developed over the last 10 years by many philosophers and cognitive scientists. The extended mind thesis (EM) affirms that the mind is not simply ensconced inside the head, but extends to the whole system of brain-body-environment. Recently, some philosophers and psychologists try to adapt the idea of EM to the domain of social cognition research. Mind is socially extended (SEM). However, EM/SEM theory has problems to analyze the interactions among a subject and its surroundings with opposition, antagonism, or conflict; it also tends to think that the environment surrounding the subject is passive or static, and to neglect the power of non-human actants to direct and regulate the human subject. In these points, actor-network theory (ANT) proposed by Latour and Callon is more persuasive, while sharing some important ideas with EM/SEM theory. Actor-network is a hybrid community which is composed of a series of heterogeneous elements, animate and inanimate for a certain period of time. I shall conclude that EM/SEM could be best analyzed as a special case of actor-network. EM/SEM is a system which can be controlled by a human agent alone. In order to understand collective behavior, philosophy and psychology have to study the actor-network in which human individuals are situated.
Characterization of Pu-238 Heat Source Granule Containment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, Paul Dean II; Sanchez, Joey Leo; Wall, Angelique Dinorah
The Milliwatt Radioisotopic Themoelectric Generator (RTG) provides power for permissive-action links. Essentially these are nuclear batteries that convert thermal energy to electrical energy using a doped silicon-germanium thermopile. The thermal energy is provided by a heat source made of 238Pu, in the form of 238PuO 2 granules. The granules are contained by 3 layers of encapsulation. A thin T-111 liner surrounds the 238PuO 2 granules and protects the second layer (strength member) from exposure to the fuel granules. An outer layer of Hastalloy-C protects the T-111 from oxygen embrittlement. The T-111 strength member is considered the critical component in thismore » 238PuO 2 containment system. Any compromise in the strength member seen during destructive testing required by the RTG surveillance program is characterized. The T-111 strength member is characterized through Scanning Electron Microscopy (SEM), and Metallography. SEM is used in the Secondary Electron mode to reveal possible grain boundary deformation and/or cracking in the region of the strength member weld. Deformation and cracking uncovered by SEM are further characterized by Metallography. Metallography sections are mounted and polished, observed using optical microscopy, then documented in the form of microphotographs. SEM mat further be used to examine polished Metallography mounts to characterize elements using the SEM mode of Energy Dispersive X-ray spectroscopy (EDS).« less
Self-expanding metallic stents drainage for acute proximal colon obstruction
Yao, Li-Qin; Zhong, Yun-Shi; Xu, Mei-Dong; Xu, Jian-Min; Zhou, Ping-Hong; Cai, Xian-Li
2011-01-01
AIM: To clarify the usefulness of the self-expanding metallic stents (SEMS) in the management of acute proximal colon obstruction due to colon carcinoma before curative surgery. METHODS: Eighty-one colon (proximal to spleen flex) carcinoma patients (47 males and 34 females, aged 18-94 years, mean = 66.2 years) treated between September 2004 and June 2010 for acute colon obstruction were enrolled to this study, and their clinical and radiological features were reviewed. After a cleaning enema was administered, urgent colonoscopy was performed. Subsequently, endoscopic decompression using SEMS placement was attempted. RESULTS: Endoscopic decompression using SEMS placement was technically successful in 78 (96.3%) of 81 patients. Three patients’ symptoms could not be relieved after SEMS placement and emergent operation was performed 1 d later. The site of obstruction was transverse colon in 18 patients, the hepatic flex in 42, and the ascending colon in 21. Following adequate cleansing of the colon, patients’ abdominal girth was decreased from 88 ± 3 cm before drainage to 72 ± 6 cm 7 d later, and one-stage surgery after 8 ± 1 d (range, 7-10 d) was performed. No anastomotic leakage or postoperative stenosis occurred after operation. CONCLUSION: SEMS placement is effective and safe in the management of acute proximal colon obstruction due to colon carcinoma, and is considered as a bridged method before curative surgery. PMID:21876623
Correlative SEM SERS for quantitative analysis of dimer nanoparticles.
Timmermans, F J; Lenferink, A T M; van Wolferen, H A G M; Otto, C
2016-11-14
A Raman microscope integrated with a scanning electron microscope was used to investigate plasmonic structures by correlative SEM-SERS analysis. The integrated Raman-SEM microscope combines high-resolution electron microscopy information with SERS signal enhancement from selected nanostructures with adsorbed Raman reporter molecules. Correlative analysis is performed for dimers of two gold nanospheres. Dimers were selected on the basis of SEM images from multi aggregate samples. The effect of the orientation of the dimer with respect to the polarization state of the laser light and the effect of the particle gap size on the Raman signal intensity is observed. Additionally, calculations are performed to simulate the electric near field enhancement. These simulations are based on the morphologies observed by electron microscopy. In this way the experiments are compared with the enhancement factor calculated with near field simulations and are subsequently used to quantify the SERS enhancement factor. Large differences between experimentally observed and calculated enhancement factors are regularly detected, a phenomenon caused by nanoscale differences between the real and 'simplified' simulated structures. Quantitative SERS experiments reveal the structure induced enhancement factor, ranging from ∼200 to ∼20 000, averaged over the full nanostructure surface. The results demonstrate correlative Raman-SEM microscopy for the quantitative analysis of plasmonic particles and structures, thus enabling a new analytical method in the field of SERS and plasmonics.
Does your SEM really tell the truth?--How would you know? Part 1.
Postek, Michael T; Vladár, András E
2013-01-01
The scanning electron microscope (SEM) has gone through a tremendous evolution to become a critical tool for many and diverse scientific and industrial applications. The high resolution of the SEM is especially suited for both qualitative and quantitative applications especially for nanotechnology and nanomanufacturing. Quantitatively, measurement, or metrology is one of the main uses. It is likely that one of the first questions asked before even the first scanning electron micrograph was ever recorded was: "… how big is that?" The quality of that answer has improved a great deal over the past few years especially since today these instruments are being used as a primary measurement tool on semiconductor processing lines to monitor the manufacturing processes. The well-articulated needs of semiconductor production prompted a rapid evolution of the instrument and its capabilities. Over the past 20 years or so, instrument manufacturers, through substantial semiconductor industry investment of research and development (R&D) money, have vastly improved the performance of these instruments. All users have benefited from this investment, especially where quantitative measurements with an SEM are concerned. But, how good are these data? This article discusses some of the most important aspects and larger issues associated with imaging and measurements with the SEM that every user should know, and understand before any critical quantitative work is attempted. © Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Takamasu, Kiyoshi; Takahashi, Satoru; Kawada, Hiroki; Ikota, Masami
2018-03-01
LER (Line Edge Roughness) and LWR (Line Width Roughness) of the semiconductor device are an important evaluation scale of the performance of the device. Conventionally, LER and LWR is evaluated from CD-SEM (Critical Dimension Scanning Electron Microscope) images. However, CD-SEM measurement has a problem that high frequency random noise is large, and resolution is not sufficiently high. For random noise of CD-SEM measurement, some techniques are proposed. In these methods, it is necessary to set parameters for model and processing, and it is necessary to verify the correctness of these parameters using reference metrology. We have already proposed a novel reference metrology using FIB (Focused Ion Beam) process and planar-TEM (Transmission Electron Microscope) method. In this study, we applied the proposed method to three new samples such as SAQP (Self-Aligned Quadruple Patterning) FinFET device, EUV (Extreme Ultraviolet Lithography) conventional resist, and EUV new material resist. LWR and PSD (Power Spectral Density) of LWR are calculated from the edge positions on planar-TEM images. We confirmed that LWR and PSD of LWR can be measured with high accuracy and evaluated the difference by the proposed method. Furthermore, from comparisons with PSD of the same sample by CD-SEM, the validity of measurement of PSD and LWR by CD-SEM can be verified.
Gentilini, Davide; Garagnani, Paolo; Pisoni, Serena; Bacalini, Maria Giulia; Calzari, Luciano; Mari, Daniela; Vitale, Giovanni; Franceschi, Claudio; Di Blasio, Anna Maria
2015-08-01
In this study we applied a new analytical strategy to investigate the relations between stochastic epigenetic mutations (SEMs) and aging. We analysed methylation levels through the Infinium HumanMethylation27 and HumanMethylation450 BeadChips in a population of 178 subjects ranging from 3 to 106 years. For each CpG probe, epimutated subjects were identified as the extreme outliers with methylation level exceeding three times interquartile ranges the first quartile (Q1-(3 x IQR)) or the third quartile (Q3+(3 x IQR)). We demonstrated that the number of SEMs was low in childhood and increased exponentially during aging. Using the HUMARA method, skewing of X chromosome inactivation (XCI) was evaluated in heterozygotes women. Multivariate analysis indicated a significant correlation between log(SEMs) and degree of XCI skewing after adjustment for age (β = 0.41; confidence interval: 0.14, 0.68; p-value = 0.0053). The PATH analysis tested the complete model containing the variables: skewing of XCI, age, log(SEMs) and overall CpG methylation. After adjusting for the number of epimutations we failed to confirm the well reported correlation between skewing of XCI and aging. This evidence might suggest that the known correlation between XCI skewing and aging could not be a direct association but mediated by the number of SEMs.
Desmosomes: A light microscopic and ultrastructural analysis of desmosomes in odontogenic cysts.
Raju, Pratima; Wadhwan, Vijay; Chaudhary, Minal S
2014-01-01
Desmosomes together with adherens junctions represent the major adhesive cell-cell junctions of epithelial cells. Any damage to these junctions leads to loss of structural balance. The present study was designed to analyze the desmosomal junctions in different odontogenic cysts and compare them with their corresponding hematoxylin and eosin (H and E) stained sections. Ten cases each of odontogenic keratocyst (OKC), dentigerous cysts (DCs), radicular cysts (RCs) and normal mucosa were stained with hematoxylin and eosin. Scanning electron microscopy (SEM) analysis of the sections was then carried out of all the sections. The area of interest on H and E stained section was marked and this marking was later superimposed onto the corresponding unstained sections and were subjected to SEM analysis. OKC at ×1000 magnification showed many prominent desmosomes. However, an increase in the intercellular space was also noted. SEM analysis demonstrated similar findings with the presence of many desmosomes, though they were seen to be damaged and fragile. H and E stained DC under oil immersion did not show any prominent desmosomes. SEM analysis of the same confirmed the observation and very minimal number were seen with a very condense arrangement of the epithelial cells. RC at ×1000 magnification revealed plenty of desmosomes, which were again confirmed by SEM. The number and quality of desmosomal junctions in all the cysts has a role in the clinical behavior of the cyst.
Simulation and Characterization of a Miniaturized Scanning Electron Microscope
NASA Technical Reports Server (NTRS)
Gaskin, Jessica A.; Jerman, Gregory A.; Medley, Stephanie; Gregory, Don; Abbott, Terry O.; Sampson, Allen R.
2011-01-01
A miniaturized Scanning Electron Microscope (mSEM) for in-situ lunar investigations is being developed at NASA Marshall Space Flight Center with colleagues from the University of Alabama in Huntsville (UAH), Advanced Research Systems (ARS), the University of Tennessee in Knoxville (UTK) and Case Western Reserve University (CWRU). This effort focuses on the characterization of individual components of the mSEM and simulation of the complete system. SEMs can provide information on the size, shape, morphology and chemical composition of lunar regolith. Understanding these basic properties will allow us to better estimate the challenges associated with In-Situ Resource Utilization and to improve our basic science knowledge of the lunar surface (either precluding the need for sample return or allowing differentiation of unique samples to be returned to Earth.) The main components of the mSEM prototype includes: a cold field emission electron gun (CFEG), focusing lens, deflection/scanning system and backscatter electron detector. Of these, the electron gun development is of particular importance as it dictates much of the design of the remaining components. A CFEG was chosen for use with the lunar mSEM as its emission does not depend on heating of the tungsten emitter (lower power), it offers a long operation lifetime, is orders of magnitude brighter than tungsten hairpin guns, has a small source size and exhibits low beam energy spread.
2014-01-01
Introduction. Self-expandable metal stents (SEMS) are a nonsurgical option for treatment of malignant colorectal obstruction also as a bridge to surgery approach. The new nitinol conformable stent has improved clinical outcomes in these kinds of patients. We report a pilot experience with nitinol conformable SEMS placement as bridge to surgery treatment in patients with colorectal obstruction. Materials and Methods. Between April and August 2012, we collected data on colonic nitinol conformable SEMS placement in a cohort of consecutive symptomatic patients, with malignant colorectal obstruction, who were treated as a bridge to surgery. Technical success, clinical success, and adverse events were recorded. Results. Ten patients (7 male (70%)), with a mean age of 69.2 ± 10.1, were evaluated. The mean length of the stenosis was 3.6 ± 0.6 cm. Five patients (50%) were treated on an emergency basis. The median time from stent placement to surgery was 16 days (interquartile range 7–21). Technical and clinical success was achieved in all patients with a significant early improvement of symptoms. No adverse events due to the SEMS placement were observed. Conclusion. This pilot study confirmed the important role of nitinol conformable SEMS as a bridge to surgery option in the treatment of symptomatic malignant colorectal obstruction. PMID:24526914
Chandler, G Thomas; Schlekat, Christian E; Garman, Emily R; He, Lijian; Washburn, Katherine M; Stewart, Emily R; Ferry, John L
2014-11-04
Robust sediment quality criteria require chemistry and toxicity data predictive of concentrations where population/community response should occur under known geochemical conditions. Understanding kinetic and geochemical effects on toxicant bioavailability is key, and these are influenced by infaunal sediment bioturbation. This study used fine-scale sediment and porewater measurement of contrasting infaunal effects on carbon-normalized SEM-AVS to evaluate safe or potentially toxic nickel concentrations in a high-binding Spartina saltmarsh sediment (4%TOC; 35-45 μmol-S2-·g(-1)). Two crustaceans producing sharply contrasting bioturbation--the copepod Amphiascus tenuiremis and amphipod Leptocheirus plumulosus--were cultured in oxic to anoxic sediments with SEM[Ni]-AVS, TOC, porewater [Ni], and porewater DOC measured weekly. From 180 to 750 μg-Ni·g(-1) sediment, amphipod bioturbation reduced [AVS] and enhanced porewater [Ni]. Significant amphipod uptake, mortality, and growth-depression occurred at the higher sediment [Ni] even when [SEM-AVS]/foc suggested acceptable risk. Less bioturbative copepods produced higher AVS and porewater DOC but exhibited net population growth despite porewater [Ni] 1.3-1.7× their aqueous [Ni] LOEC. Copepod aqueous tests with/without dissolved organic matter showed significant aqueous DOC protection, which suggests porewater DOC attenuates sediment Ni toxicity. The SEM[Ni]-AVS relationship was predictive of acceptable risk for copepods at the important population-growth level.
Plug-and-Play Environmental Monitoring Spacecraft Subsystem
NASA Technical Reports Server (NTRS)
Patel, Jagdish; Brinza, David E.; Tran, Tuan A.; Blaes, Brent R.
2011-01-01
A Space Environment Monitor (SEM) subsystem architecture has been developed and demonstrated that can benefit future spacecraft by providing (1) real-time knowledge of the spacecraft state in terms of exposure to the environment; (2) critical, instantaneous information for anomaly resolution; and (3) invaluable environmental data for designing future missions. The SEM architecture consists of a network of plug-and- play (PnP) Sensor Interface Units (SIUs), each servicing one or more environmental sensors. The SEM architecture is influenced by the IEEE Smart Transducer Interface Bus standard (IEEE Std 1451) for its PnP functionality. A network of PnP Spacecraft SIUs is enabling technology for gathering continuous real-time information critical to validating spacecraft health in harsh space environments. The demonstrated system that provided a proof-of-concept of the SEM architecture consisted of three SIUs for measurement of total ionizing dose (TID) and single event upset (SEU) radiation effects, electromagnetic interference (EMI), and deep dielectric charging through use of a prototype Internal Electro-Static Discharge Monitor (IESDM). Each SIU consists of two stacked 2X2 in. (approximately 5X5 cm) circuit boards: a Bus Interface Unit (BIU) board that provides data conversion, processing and connection to the SEM power-and-data bus, and a Sensor Interface Electronics (SIE) board that provides sensor interface needs and data path connection to the BIU.
Kunito, Takashi; Toya, Hitomi; Sumi, Hirotaka; Ishikawa, Yuichi; Toda, Hideshige; Nagaoka, Kazunari; Saeki, Kazutoshi; Aikawa, Yoshio; Matsumoto, Satoshi
2017-04-01
We examined possible adverse effects of heavy metals on microbial activity, biomass, and community composition using the simultaneously extracted metals (SEM)/acid-volatile sulfide (AVS)-based approach and measurements of exchangeable metal concentrations in three paddy soils (wastewater-contaminated soil, mine-contaminated soil, and noncontaminated soil) incubated for 60 days under flooded conditions. Incubation under flooding increased pH and decreased Eh in all samples. AVS increased when Eh decreased to approximately -200 mV for the mine-contaminated and noncontaminated soils, while the wastewater-contaminated soil originally had a high concentration of AVS despite its air-dried condition. Addition of rice straw or alkaline material containing calcium carbonate and gypsum increased AVS levels under flooded conditions. We observed no apparent relationship between soil enzyme activity (β-D-glucosidase and acid phosphatase) and concentrations of SEM, [∑SEM - AVS], and exchangeable metals. Bacterial and fungal community composition, assessed using polymerase chain reaction-denaturing gradient gel electrophoresis (DGGE) analysis targeting rRNA genes, was largely influenced by site of collection and incubation time, but metal contamination did not influence community composition. We observed significant negative correlations between biomass C and [∑SEM - AVS] and between biomass C and ∑SEM, suggesting that [∑SEM - AVS] and ∑SEM might reflect the bioavailability of organic matter to microorganisms in these soils.
Toward a Model of Strategies and Summary Writing Performance
ERIC Educational Resources Information Center
Yang, Hui-Chun
2014-01-01
This study explores the construct of a summarization test task by means of single-group and multigroup structural equation modeling (SEM). It examines the interrelationships between strategy use and performance, drawing on data from 298 Taiwanese undergraduates' summary essays and their self-reported strategy use. Single-group SEM analyses…
CHARACTERISTICS OF INDIVIDUAL PARTICLES AT A RURAL SITE IN THE EASTERN UNITED STATES
To determine the nature of aerosol particles in a rural area of the eastern United States, aerosol samples were collected at Deep Creek Lake, Maryland, on various substrates and analyzed by a scanning electron microscope (SEM) and a transmission electron microscope (TEM). SEM ana...
Surface characterization of cottonseed meal products by SEM, SEM-EDS, XRD and XPS analysis
USDA-ARS?s Scientific Manuscript database
The utilization of cottonseed meal as a valuable industrial feedstock needs to be exploited. We have recently produced water-washed cottonseed meal, total cottonseed protein, sequentially extracted water- and alkali-soluble proteins, and two residues after the total and sequential protein extraction...
Modeling the Relationships between Subdimensions of Environmental Literacy
ERIC Educational Resources Information Center
Genc, Murat; Akilli, Mustafa
2016-01-01
The aim of this study is to demonstrate the relationships between subdimensions of environmental literacy using Structural Equation Modeling (SEM). The study was conducted by the analysis of students' answers to questionnaires data using SEM. Initially, Kaiser-Meyer-Olkin and Bartlett's tests were done to test appropriateness of subdimensions to…
Multiplicity Control in Structural Equation Modeling: Incorporating Parameter Dependencies
ERIC Educational Resources Information Center
Smith, Carrie E.; Cribbie, Robert A.
2013-01-01
When structural equation modeling (SEM) analyses are conducted, significance tests for all important model relationships (parameters including factor loadings, covariances, etc.) are typically conducted at a specified nominal Type I error rate ([alpha]). Despite the fact that many significance tests are often conducted in SEM, rarely is…
Errors of Inference in Structural Equation Modeling
ERIC Educational Resources Information Center
McCoach, D. Betsy; Black, Anne C.; O'Connell, Ann A.
2007-01-01
Although structural equation modeling (SEM) is one of the most comprehensive and flexible approaches to data analysis currently available, it is nonetheless prone to researcher misuse and misconceptions. This article offers a brief overview of the unique capabilities of SEM and discusses common sources of user error in drawing conclusions from…
Bayesian Data-Model Fit Assessment for Structural Equation Modeling
ERIC Educational Resources Information Center
Levy, Roy
2011-01-01
Bayesian approaches to modeling are receiving an increasing amount of attention in the areas of model construction and estimation in factor analysis, structural equation modeling (SEM), and related latent variable models. However, model diagnostics and model criticism remain relatively understudied aspects of Bayesian SEM. This article describes…
A Methodological Review of Structural Equation Modelling in Higher Education Research
ERIC Educational Resources Information Center
Green, Teegan
2016-01-01
Despite increases in the number of articles published in higher education journals using structural equation modelling (SEM), research addressing their statistical sufficiency, methodological appropriateness and quantitative rigour is sparse. In response, this article provides a census of all covariance-based SEM articles published up until 2013…
Hara, Toru
2014-11-01
IntroductionWe installed the first "orthogonally-arranged" FIB-SEM in 2011. The most characteristic point of this instrument is that the FIB and SEM columns are perpendicularly mounted; this is specially designed to obtain a serial-sectioning dataset more accurately and precisely with higher contrast and higher spatial resolution compare to other current FIB-SEMs [1]. Since the installation in 2011, we have developed the hardware and methodology of the serial-sectioning based on this orthogonal FIB-SEM. In order to develop this technique, we have widely opened this instrument to every researcher of all fields. In the presentation, I would like to introduce some of application results that are obtained by users of this instrument. The characteristic points of the orthogonal systemFigure 1 shows a difference between the standard and the orthogonal FIB-SEM systems: In the standard system, shown in Fig.1(a), optical axes of a FIB and a SEM crosses around 60deg., while in the orthogonal system (Fig.1(b)), they are perpendicular to each other. The standard arrangement (a) is certainly suitable for TEM lamellae preparation etc. because the FIB and the SEM can see the same position simultaneously. However, for a serial-sectioning, it is not to say the best arrangement. One of the reasons is that the sliced plane by the FIB is not perpendicular to the electron beam so that the background contrast is not uniform and observed plane is distorted. On the other hand, in case of the orthogonally-arranged system,(b), these problems are resolved. In addition, spatial resolution can keep high enough even in a low accelerating voltage (e.g. 500V) because a working distance is set very small, 2mm. From these special design, we can obtain the serial-sectioning dataset from rather wide area (∼100um) with high spatial resolution (Max. 2×2×2nm). As this system has many kinds of detectors: SE, ET, Backscatter Electron(Energy-selective), EDS, EBSD, STEM(BF&ADF), with Ar+ ion-gun and a plasma cleaner, many kinds of signals can be obtained simultaneously.jmicro;63/suppl_1/i5-a/DFU077F1F1DFU077F1Fig. 1.Schematic illustration described (a) a standard type arrangement, (b) an orthogonal type arrangement. Recent topics and Future prospectsWe have applied this instrument for wide area of microstructure analysis; Metals and Alloys, Semiconductor devices, Battery electrodes, Minerals, Biomaterials, and so on. In my presentation, I would like to introduce some of our application results and will discuss about future development of the methodology of a FIB-SEM serial sectioning. As the applied research field becomes wider, various requests for the method were arisen. However, most requests can be summarized as follows: observation of larger area, expansion of applicable sample, obtain many kind of information, linkage with other instruments. AcknowledgmentsThe instrument introduced in this work was installed at NIMS by a part of "Low-carbon research network Japan" funded by the MEXT,Japan. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Lee, B.-G.; Lee, J.-S.; Luoma, S.N.; Choi, H.J.; Koh, C.-H.
2000-01-01
An 18-day microcosm study was conducted to evaluate the influence of acid volatile sulfides (AVS) and metal additions on bioaccumulation from sediments of Cd, Ni, and Zn in two clams (Macoma balthica and Potamocorbula amurensis) and three marine polychaetes (Neanthes arenaceodentata, Heteromastus filiformis, and Spiophanes missionensis). Manipulation of AVS by oxidation of naturally anoxic sediments allowed use of metal concentrations typical of nature and evaluation of processes important to chronic metal exposure. A vertical sediment column similar to that often found in nature was used to facilitate realistic biological behavior. Results showed that AVS or porewater (PW) metals controlled bioaccumulation in only 2 of 15 metal-animal combinations. Bioaccumulation of all three metals by the bivalves was related significantly to metal concentrations extracted from sediments (SEM) but not to [SEM - AVS] or PW metals. SEM predominantly influenced bioaccumulation of Ni and Zn in N. arenaceodentata, but Cd bioaccumulation followed PW Cd concentrations. SEM controlled tissue concentrations of all three metals in H. filiformis and S. missionensis, with minor influences from metal-sulfide chemistry. Significant bioaccumulation occurred when SEM was only a small fraction of AVS in several treatments. Three factors appeared to contribute to the differences between these bioaccumulation results and the results from toxicity tests reported previously: differences in experimental design, dietary uptake, and biological attributes of the species, including mode and depth of feeding.An 18-day microcosm study was conducted to evaluate the influence of acid volatile sulfides (AVS) and metal additions on bioaccumulation from sediments of Cd, Ni, and Zn in two clams (Macoma balthica and Potamocorbula amurensis) and three marine polychaetes (Neanthes arenaceodentata, Heteromastus filiformis, and Spiophanes missionensis). Manipulation of AVS by oxidation of naturally anoxic sediments allowed use of metal concentrations typical of nature and evaluation of processes important to chronic metal exposure. A vertical sediment column similar to that often found in nature was used to facilitate realistic biological behavior. Results showed that AVS or porewater (PW) metals controlled bioaccumulation in only 2 of 15 metal-animal combinations. Bioaccumulation of all three metals by the bivalves was related significantly to metal concentrations extracted from sediments (SEM) but not to [SEM - AVS] or PW metals. SEM predominantly influenced bioaccumulation of Ni and Zn in N. arenaceodentata, but Cd bioaccumulation followed PW Cd concentrations. SEM controlled tissue concentrations of all three metals in H. filiformis and S. missionensis, with minor influences from metal-sulfide chemistry. Significant bioaccumulation occurred when SEM was only a small fraction of AVS in several treatments. Three factors appeared to contribute to the differences between these bioaccumulation results and the results from toxicity tests reported previously: differences in experimental design, dietary uptake, and biological attributes of the species, including mode and depth of feeding.Microcosms were used to simulate environmentally realistic metal, acid volatile sulfide (AVS), and geochemical gradients in sediments to evaluate effects of metal bioavailability. The 18-d study involved five test species: two bivalves and three polychaetes. Two series of experiments were designed to evaluate the effects of metal concentration and AVS on bioaccumulation, respectively. The metals of interest were cadmium, nickel, and zinc. Results showed that the concentrations of pore-water Cd, Ni, and Zn were controlled by the concentration of AVS. Organisms bioaccumulated significant amounts of metals from the sediments when the simultaneously extracted metal was only a small fraction of the AVS. Bioavailability increased linearly with the sediment metal concentration irrespective of AVS or pore-w
A hybrid method for the computation of quasi-3D seismograms.
NASA Astrophysics Data System (ADS)
Masson, Yder; Romanowicz, Barbara
2013-04-01
The development of powerful computer clusters and efficient numerical computation methods, such as the Spectral Element Method (SEM) made possible the computation of seismic wave propagation in a heterogeneous 3D earth. However, the cost of theses computations is still problematic for global scale tomography that requires hundreds of such simulations. Part of the ongoing research effort is dedicated to the development of faster modeling methods based on the spectral element method. Capdeville et al. (2002) proposed to couple SEM simulations with normal modes calculation (C-SEM). Nissen-Meyer et al. (2007) used 2D SEM simulations to compute 3D seismograms in a 1D earth model. Thanks to these developments, and for the first time, Lekic et al. (2011) developed a 3D global model of the upper mantle using SEM simulations. At the local and continental scale, adjoint tomography that is using a lot of SEM simulation can be implemented on current computers (Tape, Liu et al. 2009). Due to their smaller size, these models offer higher resolution. They provide us with images of the crust and the upper part of the mantle. In an attempt to teleport such local adjoint tomographic inversions into the deep earth, we are developing a hybrid method where SEM computation are limited to a region of interest within the earth. That region can have an arbitrary shape and size. Outside this region, the seismic wavefield is extrapolated to obtain synthetic data at the Earth's surface. A key feature of the method is the use of a time reversal mirror to inject the wavefield induced by distant seismic source into the region of interest (Robertsson and Chapman 2000). We compute synthetic seismograms as follow: Inside the region of interest, we are using regional spectral element software RegSEM to compute wave propagation in 3D. Outside this region, the wavefield is extrapolated to the surface by convolution with the Green's functions from the mirror to the seismic stations. For now, these Green's functions are computed using 2D SEM simulation in a 1D Earth model. Such seismograms account for the 3D structure inside the region of interest in a quasi-exact manner. Later we plan to extrapolate the misfit function computed from such seismograms at the stations back into the SEM region in order to compute local adjoint kernels. This opens a new path toward regional adjoint tomography into the deep Earth. Capdeville, Y., et al. (2002). "Coupling the spectral element method with a modal solution for elastic wave propagation in global Earth models." Geophysical Journal International 152(1): 34-67. Lekic, V. and B. Romanowicz (2011). "Inferring upper-mantle structure by full waveform tomography with the spectral element method." Geophysical Journal International 185(2): 799-831. Nissen-Meyer, T., et al. (2007). "A two-dimensional spectral-element method for computing spherical-earth seismograms-I. Moment-tensor source." Geophysical Journal International 168(3): 1067-1092. Robertsson, J. O. A. and C. H. Chapman (2000). "An efficient method for calculating finite-difference seismograms after model alterations." Geophysics 65(3): 907-918. Tape, C., et al. (2009). "Adjoint tomography of the southern California crust." Science 325(5943): 988-992.
NASA Astrophysics Data System (ADS)
Marty, Adam J.
The purpose of this research is to demonstrate the ability to generate and characterize a nanometer sized aerosol using solutions, suspensions, and a bulk nanopowder, and to research the viability of using an acoustic dry aerosol generator/elutriator (ADAGE) to aerosolize a bulk nanopowder into a nanometer sized aerosol. The research compares the results from a portable scanning mobility particle sizer (SMPS) to the more traditional method of counting and sizing particles on a filter sample using scanning electron microscopy (SEM). Sodium chloride aerosol was used for the comparisons. The sputter coating thickness, a conductive coating necessary for SEM, was measured on different sizes of polystyrene latex spheres (PSLS). Aluminum oxide powder was aerosolized using an ADAGE and several different support membranes and sound frequency combinations were explored. A portable SMPS was used to determine the size distributions of the generated aerosols. Polycarbonate membrane (PCM) filter samples were collected for subsequent SEM analysis. The particle size distributions were determined from photographs of the membrane filters. SMPS data and membrane samples were collected simultaneously. The sputter coating thicknesses on four different sizes of PSLS, range 57 nanometers (nm) to 220 nm, were measured using transmission electron microscopy and the results from the SEM and SMPS were compared after accounting for the sputter coating thickness. Aluminum oxide nanopowder (20 nm) was aerosolized using a modified ADAGE technique. Four different support membranes and four different sound frequencies were tested with the ADAGE. The aerosol was collected onto PCM filters and the samples were examined using SEM. The results indicate that the SMPS and SEM distributions were log-normally distributed with a median diameter of approximately 42 nm and 55 nm, respectively, and geometric standard deviations (GSD) of approximately 1.6 and 1.7, respectively. The two methods yielded similar distributional trends with a difference in median diameters of approximately 11 -- 15 nm. The sputter coating thickness on the different sizes of PSLSs ranged from 15.4 -- 17.4 nm. The aerosols generated, using the modified ADAGE, were low in concentration. The particles remained as agglomerates and varied widely in size. An aluminum foil support membrane coupled with a high sound frequency generated the smallest agglomerates. A well characterized sodium chloride aerosol was generated and was reproducible. The distributions determined using SEM were slightly larger than those obtained from SMPS, however, the distributions had relatively the same shape as reflected in their GSDs. This suggests that a portable SMPS is a suitable method for characterizing a nanoaerosol. The sizing techniques could be compared after correcting for the effects of the sputter coating necessary for SEM examination. It was determined that the sputter coating thickness on nano-sized particles and particles up to approximately 220 nm can be expected to be the same and that the sputter coating can add considerably to the size of a nanoparticle. This has important implications for worker health where nanoaerosol exposure is a concern. The sputter coating must be considered when SEM is used to describe a nanoaerosol exposure. The performance of the modified ADAGE was less than expected. The low aerosol output from the ADAGE prevented a more detailed analysis and was limited to only a qualitative comparison. Some combinations of support membranes and sound frequencies performed better than others, particularly conductive support membranes and high sound frequencies. In conclusion, a portable SMPS yielded results similar to those obtained by SEM. The sputter coating was the same thickness on the PSLSs studied. The sputter coating thickness must be considered when characterizing nanoparticles using SEM. Finally, a conductive support membrane and higher frequencies appeared to generate the smallest agglomerates using the ADAGE technique.
Genome sequences of wild and domestic bactrian camels
Jirimutu; Wang, Zhen; Ding, Guohui; Chen, Gangliang; Sun, Yamin; Sun, Zhihong; Zhang, Heping; Wang, Lei; Hasi, Surong; Zhang, Yan; Li, Jianmei; Shi, Yixiang; Xu, Ze; He, Chuan; Yu, Siriguleng; Li, Shengdi; Zhang, Wenbin; Batmunkh, Mijiddorj; Ts, Batsukh; Narenbatu; Unierhu; Bat-Ireedui, Shirzana; Gao, Hongwei; Baysgalan, Banzragch; Li, Qing; Jia, Zhiling; Turigenbayila; Subudenggerile; Narenmanduhu; Wang, Zhaoxia; Wang, Juan; Pan, Lei; Chen, Yongcan; Ganerdene, Yaichil; Dabxilt; Erdemt; Altansha; Altansukh; Liu, Tuya; Cao, Minhui; Aruuntsever; Bayart; Hosblig; He, Fei; Zha-ti, A; Zheng, Guangyong; Qiu, Feng; Sun, Zikui; Zhao, Lele; Zhao, Wenjing; Liu, Baohong; Li, Chao; Chen, Yunqin; Tang, Xiaoyan; Guo, Chunyan; Liu, Wei; Ming, Liang; Temuulen; Cui, Aiying; Li, Yi; Gao, Junhui; Li, Jing; Wurentaodi; Niu, Shen; Sun, Tao; Zhai, Zhengxiao; Zhang, Min; Chen, Chen; Baldan, Tunteg; Bayaer, Tuman; Li, Yixue; Meng, He
2012-01-01
Bactrian camels serve as an important means of transportation in the cold desert regions of China and Mongolia. Here we present a 2.01 Gb draft genome sequence from both a wild and a domestic bactrian camel. We estimate the camel genome to be 2.38 Gb, containing 20,821 protein-coding genes. Our phylogenomics analysis reveals that camels shared common ancestors with other even-toed ungulates about 55–60 million years ago. Rapidly evolving genes in the camel lineage are significantly enriched in metabolic pathways, and these changes may underlie the insulin resistance typically observed in these animals. We estimate the genome-wide heterozygosity rates in both wild and domestic camels to be 1.0 × 10−3. However, genomic regions with significantly lower heterozygosity are found in the domestic camel, and olfactory receptors are enriched in these regions. Our comparative genomics analyses may also shed light on the genetic basis of the camel's remarkable salt tolerance and unusual immune system. PMID:23149746