Science.gov

Sample records for esquerdo pelo doppler

  1. Doppler echocardiography

    SciTech Connect

    Labovitz, A.J.; Williams, G.A.

    1988-01-01

    The authors are successful in presenting a basic book on clinical quantitative Doppler echocardiography. It is not intended to be a comprehensive text, but it does cover clinical applications in a succinct fashion. Only the more common diseases in the adult are considered. The subjects are presented logically and are easy to comprehend. The illustrations are good, and the book is paperbound. The basic principles of Doppler echocardiography are presented briefly. The book ends with chapters on left ventricular function (stroke volume and cardiac output), congenital heart disease, and color Doppler echo-cardiography. There are numerous references and a good glossary and index.

  2. Doppler flowmeter

    DOEpatents

    Karplus, Henry H. B.; Raptis, Apostolos C.

    1983-01-01

    A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.

  3. Doppler flowmeter

    DOEpatents

    Karplus, H.H.B.; Raptis, A.C.

    1981-11-13

    A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.

  4. DOPPLER WEATHER SYSTEM

    SciTech Connect

    Berlin, Gary J.

    2002-08-05

    The SRS Doppler Weather System consists of a Doppler Server, A Master Server (also known as the Weather Server), several Doppler Slave Servers, and client-side software program called the Doppler Radar Client. This system is used to display near rel-time images taken from the SRS Weather Center's Doppler Radar computer. The Doppler Server is software that resides on the SRS Doppler Computer. It gathers raw data, 24-bit color weather images via screen scraping ever five minutes as requested by the Master Server. The Doppler Server then reduces the 24-bit color images to 8-bit color using a fixed color table for analysis and compression. This preserves the fidelity of the image color and arranges the colors in specific order for display. At the time of color reduction, the white color used for the city names on the background images are remapped to a different index (color) of white that the white on the weather scale. The Weather Server places a time stamp on the image, then compresses the image and passes it to all Doppler Slave servers. Each of the Doppler Slave servers mainitain a circular buffer of the eight most current images representing the last 40 minutes of weather data. As a new image is added, the oldest drops off. The Doppler Radar Client is an optional install program for any site-wide workstation. When a Client session is started, the Client requests Doppler Slave server assignment from the Master Server. Upon its initial request to the Slave Server, the Client obtains all eight current images and maintains its own circular buffer, updating its images every five minutes as the Doppler Slave is updated. Three background reference images are stored as part of the Client. The Client brings up the appropriate background image, decompresses the doppler data, and displays the doppler data on the background image.

  5. Christian Doppler and the Doppler effect

    NASA Astrophysics Data System (ADS)

    Toman, Kurt

    1984-04-01

    A summary is given of Doppler's life and career. He was born 180 years ago on November 29, 1803, in Salzburg, Austria. He died on March 17, 1853 in Venice. The effect bearing his name was first announced in a presentation before the Royal Bohemian Society of the Sciences in Prague on May 25, 1842. Doppler considered his work a generalization of the aberration theorem as discovered by Bradley. With it came the inference that the perception of physical phenomena can change with the state of motion of the observer. Acceptance of the principle was not without controversy. In 1852, the mathematician Petzval claimed that no useful scientific deductions can be made from Doppler's elementary equations. In 1860, Ernst Mach resolved the misunderstanding that clouded this controversy. The Doppler effect is alive and well. Its role in radio science and related disciplines is enumerated.

  6. Advances in Doppler OCT

    PubMed Central

    Liu, Gangjun; Chen, Zhongping

    2014-01-01

    We review the principle and some recent applications of Doppler optical coherence tomography (OCT). The advances of the phase-resolved Doppler OCT method are described. Functional OCT algorithms which are based on an extension of the phase-resolved scheme are also introduced. Recent applications of Doppler OCT for quantification of flow, imaging of microvasculature and vocal fold vibration, and optical coherence elastography are briefly discussed. PMID:24443649

  7. Advanced Doppler tracking experiments

    NASA Technical Reports Server (NTRS)

    Armstrong, J. W.

    1989-01-01

    The Doppler tracking method is currently the only technique available for broadband gravitational wave searches in the approx. 10(exp -4) to 10(exp -1) Hz low frequency band. A brief review is given of the Doppler method, a discussion of the main noise sources, and a review of experience with current spacecraft and the prospects for sensitivity improvements in an advanced Doppler tracking experiment.

  8. The Cognitive Doppler.

    ERIC Educational Resources Information Center

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  9. Doppler ultrasound monitoring technology.

    PubMed

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  10. Doppler radar flowmeter

    DOEpatents

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  11. Doppler Lidar (DL) Handbook

    SciTech Connect

    Newsom, RK

    2012-02-13

    The Doppler lidar (DL) is an active remote sensing instrument that provides range- and time-resolved measurements of radial velocity and attenuated backscatter. The principle of operation is similar to radar in that pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is inferred. The radial or line-of-sight velocity of the scatterers is determined from the Doppler frequency shift of the backscattered radiation. The DL uses a heterodyne detection technique in which the return signal is mixed with a reference laser beam (i.e., local oscillator) of known frequency. An onboard signal processing computer then determines the Doppler frequency shift from the spectra of the heterodyne signal. The energy content of the Doppler spectra can also be used to determine attenuated backscatter.

  12. Pulse subtraction Doppler

    NASA Astrophysics Data System (ADS)

    Mahue, Veronique; Mari, Jean Martial; Eckersley, Robert J.; Caro, Colin G.; Tang, Meng-Xing

    2010-01-01

    Recent advances have demonstrated the feasibility of molecular imaging using targeted microbubbles and ultrasound. One technical challenge is to selectively detect attached bubbles from those freely flowing bubbles and surrounding tissue. Pulse Inversion Doppler is an imaging technique enabling the selective detection of both static and moving ultrasound contrast agents: linear scatterers generate a single band Doppler spectrum, while non-linear scatterers generate a double band spectrum, one being uniquely correlated with the presence of contrast agents and non-linear tissue signals. We demonstrate that similar spectrums, and thus the same discrimination, can be obtained through a Doppler implementation of Pulse Subtraction. This is achieved by reconstructing a virtual echo using the echo generated from a short pulse transmission. Moreover by subtracting from this virtual echo the one generated from a longer pulse transmission, it is possible to fully suppress the echo from linear scatterers, while for non-linear scatterers, a signal will remain, allowing classical agent detection. Simulations of a single moving microbubble and a moving linear scatterer subject to these pulses show that when the virtual echo and the long pulse echo are used to perform pulsed Doppler, the power Doppler spectrum allows separation of linear and non-linear moving scattering. Similar results are obtained on experimental data acquired on a flow containing either microbubble contrast agents or linear blood mimicking fluid. This new Doppler method constitutes an alternative to Pulse Inversion Doppler and preliminary results suggest that similar dual band spectrums could be obtained by the combination of any non-linear detection technique with Doppler demodulation.

  13. Doppler ion program description

    SciTech Connect

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities.

  14. Finnish Meteorological Institute Doppler Lidar

    SciTech Connect

    Ewan OConnor

    2015-03-27

    This doppler lidar system provides co-polar and cross polar attenuated backscatter coefficients,signal strength, and doppler velocities in the cloud and in the boundary level, including uncertainties for all parameters. Using the doppler beam swinging DBS technique, and Vertical Azimuthal Display (VAD) this system also provides vertical profiles of horizontal winds.

  15. The Doppler Pendulum Experiment

    ERIC Educational Resources Information Center

    Lee, C. K.; Wong, H. K.

    2011-01-01

    An experiment to verify the Doppler effect of sound waves is described. An ultrasonic source is mounted at the end of a simple pendulum. As the pendulum swings, the rapid change of frequency can be recorded by a stationary receiver using a simple frequency-to-voltage converter. The experimental results are in close agreement with the Doppler…

  16. Doppler wind profile experiment

    NASA Technical Reports Server (NTRS)

    Arnold, J. E.

    1985-01-01

    The data collection phase of a Doppler wind measurement experiment supported by high-resolution Jimsphere/FPS-16 wind data and Windsonde data was carried out at the Kennedy Space Center in February, March and early April of 1985. The Doppler wind measurements were made using a hybrid doppler profiler put in place by the Johnson Space Center and a SOUSY profiler operated by Radian Corporation. Both systems operated at 50 Mhz. Although the doppler profiler systems were located 10 km apart to enable concurrent operation of the systems for data comparison, little concurrent data were obtained due to set-up delays with the SOUSY system, and system problems with the WPL system during the last month of the test. During the test period, special serial Jimsphere soundings were taken at two-hour intervals on six days in March and April in addition to balloon soundings taken in support of the Shuttle launch operations. In addition, there is temperature, moisture and wind information available from the daily morning Radiosonde sounding taken at the Kennedy site. The balloon release point was at the same location as the SOUSY profiler. Vertical resolution of the SOUSY profiler was 150 M to approximately 20 km. The vertical resolution of the WPL profiler was 290 M to 10 km and 870 M to 17 km. Winds determined form the Jimsphere balloon have a vertical resolution of 30 M.

  17. Doppler effect in optical velocimetry

    NASA Astrophysics Data System (ADS)

    Rinkevichius, Bronius S.

    1996-02-01

    The current state of the optical metrology based on the Doppler effect has been reviewed. Some historical and scientific information is given, in addition the contemporary optical methods of the velocity measurement using the Doppler effect are analyzed. The Doppler effect applications in astrophysics, plasma physics, investigations of gas and liquid flows, acoustics, mechanics of the deforming solid body and of the rotational motion are considered. The description is presented for the following techniques of the velocity measurement: laser Doppler anemometry, laser Doppler vibrometry, laser gyroscopy.

  18. Laser Doppler anemometry

    NASA Technical Reports Server (NTRS)

    Johnson, Dennis A.

    1988-01-01

    The material in this NASA TM is to appear as a chapter on Laser Doppler Anemometry (LDA) in the AGARDograph entitled, A Survey of Measurements and Measuring Techniques in Rapidly Distorted Compressible Turbulent Boundary Layers. The application of LDA (specifically, the dual-beam, burst-counter approach) to compressible flows is discussed. Subjects treated include signal processing, particle light scattering and tracking, data reduction and sampling bias, and three-dimensional measurements.

  19. Doppler Optical Coherence Tomography

    PubMed Central

    Leitgeb, Rainer A.; Werkmeister, René M.; Blatter, Cedric; Schmetterer, Leopold

    2014-01-01

    Optical Coherence Tomography (OCT) has revolutionized ophthalmology. Since its introduction in the early 1990s it has continuously improved in terms of speed, resolution and sensitivity. The technique has also seen a variety of extensions aiming to assess functional aspects of the tissue in addition to morphology. One of these approaches is Doppler OCT (DOCT), which aims to visualize and quantify blood flow. Such extensions were already implemented in time domain systems, but have gained importance with the introduction of Fourier domain OCT. Nowadays phase-sensitive detection techniques are most widely used to extract blood velocity and blood flow from tissues. A common problem with the technique is that the Doppler angle is not known and several approaches have been realized to obtain absolute velocity and flow data from the retina. Additional studies are required to elucidate which of these techniques is most promising. In the recent years, however, several groups have shown that data can be obtained with high validity and reproducibility. In addition, several groups have published values for total retinal blood flow. Another promising application relates to non-invasive angiography. As compared to standard techniques such as fluorescein and indocyanine-green angiography the technique offers two major advantages: no dye is required and depth resolution is required is provided. As such Doppler OCT has the potential to improve our abilities to diagnose and monitor ocular vascular diseases. PMID:24704352

  20. Laser double Doppler flowmeter

    NASA Astrophysics Data System (ADS)

    Poffo, L.; Goujon, J.-M.; Le Page, R.; Lemaitre, J.; Guendouz, M.; Lorrain, N.; Bosc, D.

    2014-05-01

    The Laser Doppler flowmetry (LDF) is a non-invasive method for estimating the tissular blood flow and speed at a microscopic scale (microcirculation). It is used for medical research as well as for the diagnosis of diseases related to circulatory system tissues and organs including the issues of microvascular flow (perfusion). It is based on the Doppler effect, created by the interaction between the laser light and tissues. LDF measures the mean blood flow in a volume formed by the single laser beam, that penetrate into the skin. The size of this measurement volume is crucial and depends on skin absorption, and is not directly reachable. Therefore, current developments of the LDF are focused on the use of always more complex and sophisticated signal processing methods. On the other hand, laser Double Doppler Flowmeter (FL2D) proposes to use two laser beams to generate the measurement volume. This volume would be perfectly stable and localized at the intersection of the two laser beams. With FL2D we will be able to determine the absolute blood flow of a specific artery. One aimed application would be to help clinical physicians in health care units.

  1. Clinical applications of doppler ultrasound

    SciTech Connect

    Taylor, K.J.W.; Burns, P.N.; Well, P.N.T.

    1987-01-01

    This book introduces a guide to the physical principles and instrumentation of duplex Doppler ultrasound and its applications in obstetrics, gynecology, neonatology, gastroentology, and evaluation of peripheral vascular disease. The book provides information needed to perform Doppler ultrasound examinations and interpret the results. An introduction to Doppler physics and instrumentation is followed by a thorough review of hemodynamics, which explains the principles underlying interpretation of Doppler signals. Of special note is the state-of-the-art coverage of new applications of Doppler in recognition of high-risk pregnancy, diagnosis of intrauterine growth retardation, investigation of neonatal blood flow, evaluation of first-trimester pregnancy, and diagnosis of gastrointestinal disease. The book also offers guidelines on the use of Doppler ultrasound in diagnosing carotid disease, deep venous thrombosis, and aorta/femoral disease.

  2. Laser Doppler diagnostics for orthodontia

    NASA Astrophysics Data System (ADS)

    Ryzhkova, Anastasia V.; Lebedeva, Nina G.; Sedykh, Alexey V.; Ulyanov, Sergey S.; Lepilin, Alexander V.; Kharish, Natalia A.

    2004-06-01

    The results of statistical analysis of Doppler spectra of intensity fluctuations of light, scattered from mucous membrane of oral cavity of healthy volunteers and patients, abused by the orthodontic diseases, are presented. Analysis of Doppler spectra, obtained from tooth pulp of patients, is carried out. New approach to monitoring of blood microcirculation in orthodontics is suggested. Influence of own noise of Doppler measuring system on formation of the output signal is studied.

  3. Laser Doppler velocimetry primer

    NASA Technical Reports Server (NTRS)

    Bachalo, William D.

    1985-01-01

    Advanced research in experimental fluid dynamics required a familiarity with sophisticated measurement techniques. In some cases, the development and application of new techniques is required for difficult measurements. Optical methods and in particular, the laser Doppler velocimeter (LDV) are now recognized as the most reliable means for performing measurements in complex turbulent flows. And such, the experimental fluid dynamicist should be familiar with the principles of operation of the method and the details associated with its application. Thus, the goals of this primer are to efficiently transmit the basic concepts of the LDV method to potential users and to provide references that describe the specific areas in greater detail.

  4. ANL Doppler flowmeter

    NASA Astrophysics Data System (ADS)

    Karplus, H. B.; Raptis, A. C.; Lee, S.; Simpson, T.

    1985-10-01

    A flowmeter has been developed for measuring flow velocity in hot slurries. The flowmeter works on an ultrasonic Doppler principle in which ultrasound is injected into the flowing fluid through the solid pipe wall. Isolating waveguides separate the hot pipe from conventional ultrasonic transducers. Special clamp-on high-temperature transducers also can be adapted to work well in this application. Typical flows in pilot plants were found to be laminar, giving rise to broad-band Doppler spectra. A special circuit based on a servomechanism sensor was devised to determine the frequency average of such a broad spectrum. The device was tested at different pilot plants. Slurries with particulates greater than 70 microns (0.003 in.) yielded good signals, but slurries with extremely fine particulates were unpredictable. Small bubbles can replace the coarse particles to provide a good signal if there are not too many. Successful operation with very fine particulate slurries may have been enhanced by the presence of microbubbles.

  5. Doppler Beats or Interference Fringes?

    ERIC Educational Resources Information Center

    Kelly, Paul S.

    1979-01-01

    Discusses the following: another version of Doppler beats; alternate proof of spin-1 sin-1/2 problems; some mechanisms related to Dirac's strings; Doppler redshift in oblique approach of source and observer; undergraduate experiment on noise thermometry; use of the time evolution operator; resolution of an entropy maximization controversy;…

  6. GEOS-3 Doppler difference tracking

    NASA Technical Reports Server (NTRS)

    Rosenbaum, B.

    1977-01-01

    The Doppler difference method as applied to track the GEOS 3 spacecraft is discussed. In this method a pair of 2 GHz ground tracking stations simultaneously track a spacecraft beacon to generate an observable signal in which bias and instability of the carrier frequency cancel. The baselines are formed by the tracking sites at Bermuda, Rosman, and Merritt Island. Measurements were made to evaluate the effectiveness of the Doppler differencing procedure in tracking a beacon target with the high dynamic rate of the GEOS 3 orbit. Results indicate the precision of the differenced data to be at a level comparable to the conventional precise two way Doppler tracking.

  7. Digital Doppler measurement with spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.; Hinedi, Sami M.; Labelle, Remi C.; Bevan, Roland P.; Del Castillo, Hector M.; Chong, Dwayne C.

    1991-01-01

    Digital and analog phase-locked loop (PLL) receivers were operated in parallel, each tracking the residual carrier from a spacecraft. The PLL tracked the downlink carrier and measured its instantaneous phase. This information, combined with a knowledge of the uplink carrier and the transponder ratio, permitted the computation of a Doppler observable. In this way, two separate Doppler measurements were obtained for one observation window. The two receivers agreed on the magnitude of the Doppler effect to within 1 mHz. There was less jitter on the data from the digital receiver. This was due to its smaller noise bandwidth. The demonstration and its results are described.

  8. Evaluation of meteorological airborne Doppler radar

    NASA Technical Reports Server (NTRS)

    Hildebrand, P. H.; Mueller, C. K.

    1984-01-01

    This paper will discuss the capabilities of airborne Doppler radar for atmospheric sciences research. The evaluation is based on airborne and ground based Doppler radar observations of convective storms. The capability of airborne Doppler radar to measure horizontal and vertical air motions is evaluated. Airborne Doppler radar is shown to be a viable tool for atmospheric sciences research.

  9. Dual-Doppler Feasibility Study

    NASA Technical Reports Server (NTRS)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  10. Doppler characteristics of sea clutter.

    SciTech Connect

    Raynal, Ann Marie; Doerry, Armin Walter

    2010-06-01

    Doppler radars can distinguish targets from clutter if the target's velocity along the radar line of sight is beyond that of the clutter. Some targets of interest may have a Doppler shift similar to that of clutter. The nature of sea clutter is different in the clutter and exo-clutter regions. This behavior requires special consideration regarding where a radar can expect to find sea-clutter returns in Doppler space and what detection algorithms are most appropriate to help mitigate false alarms and increase probability of detection of a target. This paper studies the existing state-of-the-art in the understanding of Doppler characteristics of sea clutter and scattering from the ocean to better understand the design and performance choices of a radar in differentiating targets from clutter under prevailing sea conditions.

  11. Doppler tracking of planetary spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.

    1992-01-01

    This article concerns the measurement of Doppler shift on microwave links that connect planetary spacecraft with the Deep Space Network. Such measurements are made by tracking the Doppler effect with phase-locked loop receivers. A description of equipment and techniques as well as a summary of the appropriate mathematical models are given. The two-way Doppler shift is measured by transmitting a highly-stable microwave (uplink) carrier from a ground station, having the spacecraft coherently transpond this carrier, and using a phase-locked loop receiver at the ground station to track the returned (downlink) carrier. The largest sources of measurement error are usually plasma noise and thermal noise. The plasma noise, which may originate in the ionosphere or the solar corona, is discussed; and a technique to partially calibrate its effect, involving the use of two simultaneous downlink carriers that are coherently related, is described. Range measurements employing Doppler rate-aiding are also described.

  12. Mathematical Models for Doppler Measurements

    NASA Technical Reports Server (NTRS)

    Lear, William M.

    1987-01-01

    Error analysis increases precision of navigation. Report presents improved mathematical models of analysis of Doppler measurements and measurement errors of spacecraft navigation. To take advantage of potential navigational accuracy of Doppler measurements, precise equations relate measured cycle count to position and velocity. Drifts and random variations in transmitter and receiver oscillator frequencies taken into account. Mathematical models also adapted to aircraft navigation, radar, sonar, lidar, and interferometry.

  13. Novel instantaneous laser Doppler velocimeter.

    PubMed

    Avidor, J M

    1974-02-01

    A laser Doppler velocimeter capable of directly measuring instantaneous velocities is described. The new LDV uses a novel detection technique based on the utilization of a static slightly defocused spherical Fabry-Perot interferometer used in conjunction with a special mask for the detection of instantaneous Doppler frequency shifts. The essential characteristics of this LDV are discussed, and such a system recently developed is described. Results of turbulent flow measurements show good agreement with data obtained using hot wire anemometry.

  14. Adaptive spectral doppler estimation.

    PubMed

    Gran, Fredrik; Jakobsson, Andreas; Jensen, Jørgen Arendt

    2009-04-01

    In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence. The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to provide good spectral resolution and contrast even when the observation window is very short. The 2 adaptive techniques are tested and compared with the averaged periodogram (Welch's method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set of matched filters (one for each velocity component of interest) and filtering the blood process over slow-time and averaging over depth to find the PSD. The methods are tested using various experiments and simulations. First, controlled flow-rig experiments with steady laminar flow are carried out. Simulations in Field II for pulsating flow resembling the femoral artery are also analyzed. The simulations are followed by in vivo measurement on the common carotid artery. In all simulations and experiments it was concluded that the adaptive methods display superior performance for short observation windows compared with the averaged periodogram. Computational costs and implementation details are also discussed.

  15. High Resolution Doppler Lidar

    NASA Technical Reports Server (NTRS)

    1996-01-01

    This Grant supported the development of an incoherent lidar system to measure winds and aerosols in the lower atmosphere. During this period the following activities occurred: (1) an active feedback system was developed to improve the laser frequency stability; (2) a detailed forward model of the instrument was developed to take into account many subtle effects, such as detector non-linearity; (3) a non-linear least squares inversion method was developed to recover the Doppler shift and aerosol backscatter without requiring assumptions about the molecular component of the signal; (4) a study was done of the effects of systematic errors due to multiple etalon misalignment. It was discovered that even for small offsets and high aerosol loadings, the wind determination can be biased by as much as 1 m/s. The forward model and inversion process were modified to account for this effect; and (5) the lidar measurements were validated using rawinsonde balloon measurements. The measurements were found to be in agreement within 1-2 m/s.

  16. High Resolution Doppler Imager

    NASA Technical Reports Server (NTRS)

    Hays, Paul B.

    1999-01-01

    This report summarizes the accomplishments of the High Resolution Doppler Imager (HRDI) on UARS spacecraft during the period 4/l/96 - 3/31/99. During this period, HRDI operation, data processing, and data analysis continued, and there was a high level of vitality in the HRDI project. The HRDI has been collecting data from the stratosphere, mesosphere, and lower thermosphere since instrument activation on October 1, 1991. The HRDI team has stressed three areas since operations commenced: 1) operation of the instrument in a manner which maximizes the quality and versatility of the collected data; 2) algorithm development and validation to produce a high-quality data product; and 3) scientific studies, primarily of the dynamics of the middle atmosphere. There has been no significant degradation in the HRDI instrument since operations began nearly 8 years ago. HRDI operations are fairly routine, although we have continued to look for ways to improve the quality of the scientific product, either by improving existing modes, or by designing new ones. The HRDI instrument has been programmed to collect data for new scientific studies, such as measurements of fluorescence from plants, measuring cloud top heights, and lower atmosphere H2O.

  17. Doppler Ultrasound: What Is It Used for?

    MedlinePlus

    ... in your neck (carotid artery stenosis) A Doppler ultrasound can estimate how fast blood flows by measuring the rate of change in its pitch (frequency). During a Doppler ultrasound, a technician trained in ultrasound imaging (sonographer) presses ...

  18. Right Ventricular Tissue Doppler in Space Flight

    NASA Technical Reports Server (NTRS)

    Garcia, Kathleen M.; Hamilton, Douglas R.; Sargsyan, Ashot E.; Ebert, Douglas; Martin, David S.; Barratt, Michael R.; Martin, David S.; Bogomolov, Valery V.; Dulchavsky, Scott A.; Duncan, J. Michael

    2010-01-01

    The presentation slides review normal physiology of the right ventricle in space, general physiology of the right ventricle; difficulties in imaging the heart in space, imaging methods, tissue Doppler spectrum, right ventricle tissue Doppler, and Rt Tei Index.

  19. Understanding Doppler Broadening of Gamma Rays

    SciTech Connect

    Rawool-Sullivan, Mohini; Sullivan, John P.

    2014-07-03

    Doppler-broadened gamma ray peaks are observed routinely in the collection and analysis of gamma-ray spectra. If not recognized and understood, the appearance of Doppler broadening can complicate the interpretation of a spectrum and the correct identification of the gamma ray-emitting material. We have conducted a study using a simulation code to demonstrate how Doppler broadening arises and provide a real-world example in which Doppler broadening is found. This report describes that study and its results.

  20. The Doppler Effect--A New Approach

    ERIC Educational Resources Information Center

    Allen, J.

    1973-01-01

    Discusses the Doppler effect as it applies to different situations, such as a stationary source of sound with the observer moving, a stationary observer, and the sound source and observer both moving. Police radar, satellite surveillance radar, radar astronomy, and the Doppler navigator, are discussed as applications of Doppler shift. (JR)

  1. Doppler observations of solar rotation

    NASA Technical Reports Server (NTRS)

    Scherrer, P. H.

    1980-01-01

    Daily observations of the photospheric equatorial rotation rate using the Doppler effect mode at the Sanford Solar Observatory are presented. These observations show no variations in the rotation rate that exceed the observational error of about one percent. The average rotation rate is indistinguishable from that of sunspots and large scale magnetic field structures.

  2. Doppler observations of solar rotation

    NASA Technical Reports Server (NTRS)

    Scherrer, P. H.; Wilcox, J. M.

    1980-01-01

    Daily observations of the photospheric equatorial rotation rate using the Doppler effect are made at the Stanford Solar Observatory. These observations show no variations in the rotation rate that exceed the observational error of about 1%. The average rotation rate is indistinguishable from that of sunspots and large-scale magnetic field structures.

  3. Doppler Imaging of EI Eridani

    NASA Astrophysics Data System (ADS)

    Washuettl, Albert; Strassmeier, Klaus G.; Collier-Cameron, Andrew

    We present Doppler images of the rapidly rotating active close binary star EI Eridani. Several Doppler images have been produced since 1984 making use of different versions of the Doppler imaging technique. They all show high-latitude spots surrounding or covering the rotational pole as well as some smaller spots on lower latitudes. The high-latitude/polar spot seems to be long-lived (at least a decade) but changes its shape on comparatively short timescales (of the order of one month). From time to time spots along the stellar equator also occur, but their lifetimes tend to be relatively short (weeks). Furthermore, long-term photometric observations revealed the existence of a magnetic cycle which has been estimated to be around 11 years. We also present time-resolved Doppler images from EI Eri obtained at McMath/NSO in fall 1996 during 70 consecutive nights. The final aim of this program is to investigate the spot evolution over the whole activity cycle.

  4. Ultrasound imaging for the rheumatologist. XVII. Role of colour Doppler and power Doppler.

    PubMed

    Iagnocco, A; Epis, O; Delle Sedie, A; Meenagh, G; Filippucci, E; Riente, L; Scirè, C A; Montecucco, C; Bombardieri, S; Grassi, W; Valesini, G

    2008-01-01

    The use of Doppler ultrasound in rheumatology has grown in recent years. This is partly due to the increasing number of rheumatologists who perform US in their daily clinical practise and also to the technological advances of US systems. Both colour Doppler and power Doppler are used to evaluate the degree of intra- and peri-articular soft tissue inflammation. Moreover, Doppler US has been found to be of help in the assessment of vascular pathologies such as the vasculitides. In this review we provide an update of the data regarding the use of colour Doppler and power Doppler in rheumatology.

  5. Measurement of the Doppler power of flowing blood using ultrasound Doppler devices.

    PubMed

    Huang, Chih-Chung; Chou, Hung-Lung; Chen, Pay-Yu

    2015-02-01

    Measurement of the Doppler power of signals backscattered from flowing blood (henceforth referred to as the Doppler power of flowing blood) and the echogenicity of flowing blood have been used widely to assess the degree of red blood cell (RBC) aggregation for more than 20 y. Many studies have used Doppler flowmeters based on an analogue circuit design to obtain the Doppler shifts in the signals backscattered from flowing blood; however, some recent studies have mentioned that the analogue Doppler flowmeter exhibits a frequency-response problem whereby the backscattered energy is lost at higher Doppler shift frequencies. Therefore, the measured Doppler power of flowing blood and evaluations of RBC aggregation obtained using an analogue Doppler device may be inaccurate. To overcome this problem, the present study implemented a field-programmable gate array-based digital pulsed-wave Doppler flowmeter to measure the Doppler power of flowing blood, in the aim of providing more accurate assessments of RBC aggregation. A clinical duplex ultrasound imaging system that can acquire pulsed-wave Doppler spectrograms is now available, but its usefulness for estimating the ultrasound scattering properties of blood is still in doubt. Therefore, the echogenicity and Doppler power of flowing blood under the same flow conditions were measured using a laboratory pulser-receiver system and a clinical ultrasound system, respectively, for comparisons. The experiments were carried out using porcine blood under steady laminar flow with both RBC suspensions and whole blood. The experimental results indicated that a clinical ultrasound system used to measure the Doppler spectrograms is not suitable for quantifying Doppler power. However, the Doppler power measured using a digital Doppler flowmeter can reveal the relationship between backscattering signals and the properties of blood cells because the effects of frequency response are eliminated. The measurements of the Doppler power and

  6. Performance Of A Doppler-Corrected MDPSK Detector

    NASA Technical Reports Server (NTRS)

    Nguyen, Tien M.; Jedrey, Thomas C.; Hinedi, Sami; Agan, Martin J.

    1994-01-01

    Report presents theoretical analysis of effect of rate of change of Doppler shift of received multiple-differential-phase-shift-keyed (MDPSK) radio signal on performance of Doppler-corrected differential detector. In particular detector, phase of received signal corrected for Doppler shift by use of Doppler estimator designed to operate in presence of negligibly small Doppler rate.

  7. Equations for Bistatic Doppler Shift and Rate of Change of Doppler Shift of Dark Satellite Observations

    DTIC Science & Technology

    Equations are given for the doppler shift and rate of change of doppler shift for the bistatic case where an orbiting, nontransmitting earth... of change of doppler shift, satellite height, earth-center angle between the receiver and the satellite, and zenith angle from receiver to satellite are shown for a typical satellite, 1958 Alpha, Explorer I....have been computed, using transmitting and receiving sites of the Space Surveillance System. Plots of various relationships between doppler shift, rate

  8. Airborne Differential Doppler Weather Radar

    NASA Technical Reports Server (NTRS)

    Meneghini, R.; Bidwell, S.; Liao, L.; Rincon, R.; Heymsfield, G.; Hildebrand, Peter H. (Technical Monitor)

    2001-01-01

    The Precipitation Radar aboard the Tropical Rain Measuring Mission (TRMM) Satellite has shown the potential for spaceborne sensing of snow and rain by means of an incoherent pulsed radar operating at 13.8 GHz. The primary advantage of radar relative to passive instruments arises from the fact that the radar can image the 3-dimensional structure of storms. As a consequence, the radar data can be used to determine the vertical rain structure, rain type (convective/stratiform) effective storm height, and location of the melting layer. The radar, moreover, can be used to detect snow and improve the estimation of rain rate over land. To move toward spaceborne weather radars that can be deployed routinely as part of an instrument set consisting of passive and active sensors will require the development of less expensive, lighter-weight radars that consume less power. At the same time, the addition of a second frequency and an upgrade to Doppler capability are features that are needed to retrieve information on the characteristics of the drop size distribution, vertical air motion and storm dynamics. One approach to the problem is to use a single broad-band transmitter-receiver and antenna where two narrow-band frequencies are spaced apart by 5% to 10% of the center frequency. Use of Ka-band frequencies (26.5 GHz - 40 GHz) affords two advantages: adequate spatial resolution can be attained with a relatively small antenna and the differential reflectivity and mean Doppler signals are directly related to the median mass diameter of the snow and raindrop size distributions. The differential mean Doppler signal has the additional property that this quantity depends only on that part of the radial speed of the hydrometeors that is drop-size dependent. In principle, the mean and differential mean Doppler from a near-nadir viewing radar can be used to retrieve vertical air motion as well as the total mean radial velocity. In the paper, we present theoretical calculations for the

  9. Observation of the Zero Doppler Effect.

    PubMed

    Ran, Jia; Zhang, Yewen; Chen, Xiaodong; Fang, Kai; Zhao, Junfei; Chen, Hong

    2016-04-05

    The normal Doppler effect has well-established applications in many areas of science and technology. Recently, a few experimental demonstrations of the inverse Doppler effect have begun to appear in negative-index metamaterials. Here we report an experimental observation of the zero Doppler effect, that is, no frequency shift irrespective of the relative motion between the wave signal source and the detector in a zero-index metamaterial. This unique phenomenon, accompanied by the normal and inverse Doppler effects, is generated by reflecting a wave from a moving discontinuity in a composite right/left-handed transmission line loaded with varactors when operating in the near zero-index passband, or the right/left-handed passband. This work has revealed a complete picture of the Doppler effect in metamaterials and may lead to potential applications in electromagnetic wave related metrology.

  10. Development of the doppler electron velocimeter: theory.

    SciTech Connect

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  11. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    NASA Astrophysics Data System (ADS)

    Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.

    2016-08-01

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  12. Inverse Doppler Effects in Broadband Acoustic Metamaterials.

    PubMed

    Zhai, S L; Zhao, X P; Liu, S; Shen, F L; Li, L L; Luo, C R

    2016-08-31

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with 'flute-like' acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  13. Laser Doppler dust devil measurements

    NASA Technical Reports Server (NTRS)

    Bilbro, J. W.; Jeffreys, H. B.; Kaufman, J. W.; Weaver, E. A.

    1977-01-01

    A scanning laser doppler velocimeter (SLDV) system was used to detect, track, and measure the velocity flow field of naturally occurring tornado-like flows (dust devils) in the atmosphere. A general description of the dust devil phenomenon is given along with a description of the test program, measurement system, and data processing techniques used to collect information on the dust devil flow field. The general meteorological conditions occurring during the test program are also described, and the information collected on two selected dust devils are discussed in detail to show the type of information which can be obtained with a SLDV system. The results from these measurements agree well with those of other investigators and illustrate the potential for the SLDV in future endeavors.

  14. Rotational Doppler effect in nonlinear optics

    NASA Astrophysics Data System (ADS)

    Li, Guixin; Zentgraf, Thomas; Zhang, Shuang

    2016-08-01

    The translational Doppler effect of electromagnetic and sound waves has been successfully applied in measurements of the speed and direction of vehicles, astronomical objects and blood flow in human bodies, and for the Global Positioning System. The Doppler effect plays a key role for some important quantum phenomena such as the broadened emission spectra of atoms and has benefited cooling and trapping of atoms with laser light. Despite numerous successful applications of the translational Doppler effect, it fails to measure the rotation frequency of a spinning object when the probing wave propagates along its rotation axis. This constraint was circumvented by deploying the angular momentum of electromagnetic waves--the so-called rotational Doppler effect. Here, we report on the demonstration of rotational Doppler shift in nonlinear optics. The Doppler frequency shift is determined for the second harmonic generation of a circularly polarized beam passing through a spinning nonlinear optical crystal with three-fold rotational symmetry. We find that the second harmonic generation signal with circular polarization opposite to that of the fundamental beam experiences a Doppler shift of three times the rotation frequency of the optical crystal. This demonstration is of fundamental significance in nonlinear optics, as it provides us with insight into the interaction of light with moving media in the nonlinear optical regime.

  15. Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment.

    PubMed

    Ramnarine, K V; Hoskins, P R; Routh, H F; Davidson, F

    1999-01-01

    The Doppler backscatter properties of a blood-mimickig fluid (BMF) were studied to evaluate its suitability for use in a Doppler flow test object. Measurements were performed using a flow rig with C-flex tubing and BMF flow produced by a roller pump or a gear pump. A SciMed Doppler system was used to measure the backscattered Doppler power with a root-mean-square power meter connected to the audio output. Studies investigated the dependence of the backscattered Doppler power of the BMF with: circulation time; batch and operator preparations; storage; sieve size; flow speed; and pump type. A comparison was made with human red blood cells resuspended in saline. The backscatter properties are stable and within International Electrotechnical Commission requirements. The BMF is suitable for use in a test object for Doppler performance assessment.

  16. IIP Update: A Packaged Coherent Doppler Wind Lidar Transceiver. Doppler Aerosol WiNd Lidar (DAWN)

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.; Koch, Grady J.; Yu, Jirong; Trieu, Bo C.; Amzajerdian, Farzin; Singh, Upendra N.; Petros, Mulugeta

    2006-01-01

    The state-of-the-art 2-micron coherent Doppler wind lidar breadboard at NASA/LaRC will be engineered and compactly packaged consistent with future aircraft flights. The packaged transceiver will be integrated into a coherent Doppler wind lidar system test bed at LaRC. Atmospheric wind measurements will be made to validate the packaged technology. This will greatly advance the coherent part of the hybrid Doppler wind lidar solution to the need for global tropospheric wind measurements.

  17. Teaching the Doppler effect in astrophysics

    NASA Astrophysics Data System (ADS)

    Hughes, Stephen W.; Cowley, Michael

    2017-03-01

    The Doppler effect is a shift in the frequency of waves emitted from an object moving relative to the observer. By observing and analysing the Doppler shift in electromagnetic waves from astronomical objects, astronomers gain greater insight into the structure and operation of our Universe. In this paper, a simple technique is described for teaching the basics of the Doppler effect to undergraduate astrophysics students using acoustic waves. An advantage of the technique is that it produces a visual representation of the acoustic Doppler shift. The equipment comprises a 40 kHz acoustic transmitter and a microphone. The sound is bounced off a computer fan and the signal collected by a DrDAQ ADC and processed by a spectrum analyser. Widening of the spectrum is observed as the fan power supply potential is increased from 4 to 12 V.

  18. Generalized Doppler Formula in a Nonstatic Universe

    ERIC Educational Resources Information Center

    Gross, Peter G.

    1977-01-01

    Derives the general Doppler formula in a nonstatic universe using assumptions of special relativity, homogeneity and isotropy of the universe. Examples of applications to physical cosmology are given. (SL)

  19. Student Microwave Experiments Involving the Doppler Effect.

    ERIC Educational Resources Information Center

    Weber, F. Neff; And Others

    1980-01-01

    Described is the use of the Doppler Effect with microwaves in the measurement of the acceleration due to gravity of falling objects. The experiments described add to the repertoire of quantitative student microwave experiments. (Author/DS)

  20. [Cerebral Doppler ultrasonography in newborn infants].

    PubMed

    Luciano, R; Velardi, F

    1995-01-01

    Following the first study of Bada et al. (1979), Doppler assessment of cerebral blood flow has increasingly been used in newborn infants, matching the technical progress in the available equipment. The experience gathered in recent years has confirmed that Doppler US is a reliable and reproducible examination while precising the limitations and the methodology to be followed in order to prevent gross errors of assessment and interpretation. The interest this procedure has arisen, among other things, stems from being noninvasive and feasible at the patient's bed. These features enable its repeated use in newborn infants in poor clinical condition. The diagnostic and prognostic role of Doppler velocimetry has been shown in a number of neonatal diseases and the cerebral hemodynamics has been assessed in physiologic conditions as well as after drug administration. The most common equipment used in newborn infants is at present Duplex Doppler consisting of a pulsed Doppler combined with bidimensional scanner, which, with visualization of study arteries, enables precise positioning of sample volume and correction of the ultrasonic angle of incidence with respect to the direction of blood flow in the examined vessel. In this report, after a survey of the techniques and modalities of cerebral Doppler examination in newborns, a review of the present state of the art, in neonatal cerebral as well as extracranial disease, is presented.

  1. Doppler micro sense and avoid radar

    NASA Astrophysics Data System (ADS)

    Gorwara, Ashok; Molchanov, Pavlo; Asmolova, Olga

    2015-10-01

    There is a need for small Sense and Avoid (SAA) systems for small and micro Unmanned Aerial Systems (UAS) to avoid collisions with obstacles and other aircraft. The proposed SAA systems will give drones the ability to "see" close up and give them the agility to maneuver through tight areas. Doppler radar is proposed for use in this sense and avoid system because in contrast to optical or infrared (IR) systems Doppler can work in more harsh conditions such as at dusk, and in rain and snow. And in contrast to ultrasound based systems, Doppler can better sense small sized obstacles such as wires and it can provide a sensing range from a few inches to several miles. An SAA systems comprised of Doppler radar modules and an array of directional antennas that are distributed around the perimeter of the drone can cover the entire sky. These modules are designed so that they can provide the direction to the obstacle and simultaneously generate an alarm signal if the obstacle enters within the SAA system's adjustable "Protection Border". The alarm signal alerts the drone's autopilot to automatically initiate an avoidance maneuver. A series of Doppler radar modules with different ranges, angles of view and transmitting power have been designed for drones of different sizes and applications. The proposed Doppler radar micro SAA system has simple circuitry, works from a 5 volt source and has low power consumption. It is light weight, inexpensive and it can be used for a variety of small unmanned aircraft.

  2. Doppler-corrected differential detection system

    NASA Technical Reports Server (NTRS)

    Simon, Marvin K. (Inventor); Divsalar, Dariush (Inventor)

    1991-01-01

    Doppler in a communication system operating with a multiple differential phase-shift-keyed format (MDPSK) creates an adverse phase shift in an incoming signal. An open loop frequency estimation is derived from a Doppler-contaminated incoming signal. Based upon the recognition that, whereas the change in phase of the received signal over a full symbol contains both the differentially encoded data and the Doppler induced phase shift, the same change in phase over half a symbol (within a given symbol interval) contains only the Doppler induced phase shift, and the Doppler effect can be estimated and removed from the incoming signal. Doppler correction occurs prior to the receiver's final output of decoded data. A multiphase system can operate with two samplings per symbol interval at no penalty in signal-to-noise ratio provided that an ideal low pass pre-detection filter is employed, and two samples, at 1/4 and 3/4 of the symbol interval T sub s, are taken and summed together prior to incoming signal data detection.

  3. Retroreflector for photonic Doppler velocimetry

    NASA Astrophysics Data System (ADS)

    Lagoski, Thomas J.; Coutu, Ronald A., Jr.; Starman, LaVern A.

    2009-08-01

    In order to meet the goals of the Department of Defense (DoD) for smaller and more accurate weapons, numerous projects are currently investigating the miniaturization of weapons and munition fuze components. One of these efforts is to characterize the performance of small detonators. The velocity of the flyer, the key component needed to initiate a detonation sequence, can be measured using a photonic Doppler velocimeter (PDV). The purpose of this research was to develop a microelectromechanical system (MEMS) device that would act as an optimal retroreflective surface for the PDV. Two MEMS solutions were explored: one using the PolyMUMPsTM fabrication process and one in-house fabrication design using silicon on insulator (SOI) wafers. The in-house design consisted of an array of corner reflectors created using an SOI wafer. Each corner reflector consisted of three separate mirror plates which were self-assembled by photoresist pad hinges. When heated to a critical temperature (typically 140-160 °C), the photoresist pads melted and the resulting surface tension caused each mirror to rotate into place. The resulting array of corner reflectors was then coated with a thin layer of gold to increase reflectivity. Despite the successful assembly of a PolyMUMPsTM corner reflector, assembling an array of these reflectors was found to be unfeasible. Although the SOI corner reflector design was completed, these devices were not fabricated in time for testing during this research. However, the bidirectional reflectance distribution function (BRDF) and optical cross section (OCS) of commercially available retroreflective tapes were measured. These results can be used as a baseline comparison for future testing of a fabricated SOI corner reflector array.

  4. The leicester Doppler phantom--a digital electronic phantom for ultrasound pulsed Doppler system testing.

    PubMed

    Gittins, John; Martin, Kevin

    2010-04-01

    Doppler flow and string phantoms have been used to assess the performance of ultrasound Doppler systems in terms of parameters such as sensitivity, velocity accuracy and sample volume registration. However, because of the nature of their construction, they cannot challenge the accuracy and repeatability of modern digital ultrasound systems or give objective measures of system performance. Electronic Doppler phantoms are able to make use of electronically generated test signals, which may be controlled precisely in terms of frequency, amplitude and timing. The Leicester Electronic Doppler Phantom uses modern digital signal processing methods and field programmable gate array technology to overcome some of the limitations of previously described electronic phantoms. In its present form, it is able to give quantitative graphical assessments of frequency response and range gate characteristics, as well as measures of dynamic range and velocity measurement accuracy. The use of direct acoustic coupling eliminates uncertainties caused by Doppler beam effects, such as intrinsic spectral broadening, but prevents their evaluation.

  5. Doppler-guided retrograde catheterization system

    NASA Astrophysics Data System (ADS)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  6. Doppler estimation accuracy of linear FM waveforms

    NASA Astrophysics Data System (ADS)

    Daum, F. E.

    The single-pulse Doppler estimation accuracy of an unweighted linear FM waveform is analyzed in detail. Simple formulas are derived that predict that one-sigma Doppler estimation error for realistic radar applications. The effects of multiple target interference and nonlinearlities in the radar measurements are considered. In addition, a practical method to estimate Doppler frequency is presented. This technique uses the phase data after pulse compression, and it limits the effect of multiple target interference. In contrast, the available literature is based on the Cramer-Rao bound for Doppler accuracy, which ignores the effects of nonlinearities, multiple target interference and the question of practical implementation. A simple formula is derived that predicts the region of validity for the Cramer-Rao bound. This formula provides a criterion for minimum signal-to-noise ratio in terms of time-bandwidth product. Finally, an important concept that is demonstrated in this paper is that: the bulk of the Doppler information in a linear FM pulse is encoded in the range sidelobes after pulse compression.

  7. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    PubMed Central

    Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.

    2016-01-01

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe. PMID:27578317

  8. Spacecraft Doppler Tracking as a Xylophone Detector

    NASA Technical Reports Server (NTRS)

    Tinto, Massimo

    1996-01-01

    We discuss spacecraft Doppler tracking in which Doppler data recorded on the ground are linearly combined with Doppler measurements made on board a spacecraft. By using the four-link radio system first proposed by Vessot and Levine, we derive a new method for removing from the combined data the frequency fluctuations due to the Earth troposphere, ionosphere, and mechanical vibrations of the antenna on the ground. Our method provides also for reducing by several orders of magnitude, at selected Fourier components, the frequency fluctuations due to other noise sources, such as the clock on board the spacecraft or the antenna and buffeting of the probe by non-gravitational forces. In this respect spacecraft Doppler tracking can be regarded as a xylophone detector. Estimates of the sensitivities achievable by this xylophone are presented for two tests of Einstein's theory of relativity: searches for gravitational waves and measurements of the gravitational red shift. This experimental technique could be extended to other tests of the theory of relativity, and to radio science experiments that rely on high-precision Doppler measurements.

  9. Color Doppler sonography in obstetrics and gynecology.

    PubMed

    Fleischer, Arthur C; Andreotti, Rochelle F

    2005-09-01

    This review aims to provide the reader with an overview of the present and future clinical applications in color Doppler sonography for the evaluation of vascularity and blood flow within the uterus (both gravid and nongravid), ovaries, fetus and placenta. The clinical use of color Doppler sonography has been demonstrated within many organ systems. Color Doppler sonography has become an integral part of cardiovascular imaging. Significant improvements have recently occurred, improving the visualization and evaluation of intra-organ vascularity, resulting from enhancements in delineation of tissue detail through electronic compounding and harmonics, as well as enhancements in signal processing of frequency- and/or amplitude-based color Doppler sonography. Spatial representation of vascularity can be improved by utilizing 3D and 4D (live 3D) processing. Greater sensitivity of color Doppler sonography to macro- and microvascular flow has provided improved anatomic and physiologic assessment throughout pregnancy and for pelvic organs. The potential use of contrast enhancement is also mentioned as a means to further differentiate benign from malignant ovarian lesions. The rapid development of these new sonographic techniques will continue to enlarge the scope of clinical applications in a variety of obstetric and gynecologic disorders.

  10. Real-time virtual Doppler ultrasound

    NASA Astrophysics Data System (ADS)

    Khoshniat, Mahdieh; Thorne, Meghan L.; Poepping, Tamie L.; Holdsworth, David W.; Steinman, David A.

    2004-04-01

    Doppler ultrasound (DUS) is widely used to diagnose and plan treatments for vascular diseases, but the relationship between complex blood flow dynamics and the observed DUS signal is not completely understood. In this paper, we demonstrate that Doppler ultrasound can be realistically simulated in a real-time manner via the coupling of a known, previously computed velocity field with a simple model of the ultrasound physics. In the present case a 3D computational fluid dynamics (CFD) model of physiologically pulsatile flow a stenosed carotid bifurcation was interrogated using a sample volume of known geometry and power distribution. Velocity vectors at points within the sample volume were interpolated using a fast geometric search algorithm and, using the specified US probe characteristics and orientation, converted into Doppler shifts for subsequent display as a Doppler spectrogram or color DUS image. The important effect of the intrinsic spectral broadening was simulated by convolving the velocity at each point within the sample volume by a triangle function whose width was proportional to velocity. A spherical sample volume with a Gaussian power distribution was found to be adequate for producing realistic Doppler spectrogram in regions of uniform, jet, and recirculation flow. Fewer than 1000 points seeded uniformly within a radius comprising more than 99% of the total power were required, allowing spectra to be generated from high resolution CFD data at 100Hz frame rates on an inexpensive desktop workstation.

  11. Doppler Imaging of Exoplanets and Brown Dwarfs

    NASA Astrophysics Data System (ADS)

    Crossfield, I.; Biller, B.; Schlieder, J.; Deacon, N.; Bonnefoy, M.; Homeier, D.; Allard, F.; Buenzli, E.; Henning, T.; Brandner, W.; Goldman, Bertr; Kopytova, T.

    2014-03-01

    Doppler Imaging produces 2D global maps. When applied to cool planets or more massive brown dwarfs, it can map atmospheric features and track global weather patterns. The first substellar map, of the 2pc-distant brown dwarf Luhman 16B (Crossfeld et al. 2014), revealed patchy regions of thin & thick clouds. Here, I investigate the feasibility of future Doppler Imaging of additional objects. Searching the literature, I find that all 3 of P, v sin i, and variability are published for 22 brown dwarfs. At least one datum exists for 333 targets. The sample is very incomplete below ~L5; we need more surveys to find the best targets for Doppler Imaging! I estimate limiting magnitudes for Doppler Imaging with various hi-resolution near-infrared spectrographs. Only a handful of objects - at the M/L and L/T transitions - can be mapped with current tools. Large telescopes such as TMT and GMT will allow Doppler Imaging of many dozens of brown dwarfs and the brightest exoplanets. More targets beyond type L5 likely remain to be found. Future observations will let us probe the global atmospheric dynamics of many diverse objects.

  12. The EVE Doppler Sensitivity and Flare Observations

    NASA Technical Reports Server (NTRS)

    Hudson, H. S.; Woods, T. N.; Chamberlin, P. C.; Didkovsky, L.; Del Zanna, G.

    2011-01-01

    The Extreme-ultraviolet Variability Experiment (EVE) obtains continuous EUV spectra of the Sun viewed as a star. Its primary objective is the characterization of solar spectral irradiance, but its sensitivity and stability make it extremely interesting for observations of variability on time scales down to the limit imposed by its basic 10 s sample interval. In this paper we characterize the Doppler sensitivity of the EVE data. We find that the 30.4 nm line of He II has a random Doppler error below 0.001 nm (1 pm, better than 10 km/s as a redshift), with ample stability to detect the orbital motion of its satellite, the Solar Dynamics Observatory (SDO). Solar flares also displace the spectrum, both because of Doppler shifts and because of EVE's optical layout, which (as with a slitless spectrograph) confuses position and wavelength. As a flare develops, the centroid of the line displays variations that reflect Doppler shifts and therefore flare dynamics. For the impulsive phase of the flare SOL2010-06-12, we find the line centroid to have a redshift of 16.8 +/- 5.9 km/s relative to that of the flare gradual phase (statistical errors only). We find also that high-temperature lines, such as Fe XXIV 19.2 nm, have well-determined Doppler components for major flares, with decreasing apparent blueshifts as expected from chromospheric evaporation flows.

  13. Doppler-corrected differential detection of MPSK

    NASA Technical Reports Server (NTRS)

    Simon, Marvin K.; Divsalar, Dariush

    1989-01-01

    An open-loop technique is presented for estimating and correcting Doppler frequency shift in an M-ary differential phase-shift-keyed (MDPSK) receiver. The novelty of the scheme is based on the observation that whereas the change in phase of the received signal over a full symbol contains the sum of the data (phase) and the Doppler-induced phase shift, the same change in phase over half a symbol (within a given symbol interval) contains only the Doppler-induced phase shift. Thus, by proper processing, the latter can be estimated and removed from the former. Analytical and simulation results are given for the variance of the above estimator, and the error probability performance of the MDPSK receiver is evaluated in the presence of the Doppler correction. Next, the practical considerations associated with the application of this technique on bandlimited Nyquist channels are discussed and incorporated into the final design. It is shown that the receiver can, in the absence of timing jitter, be designed to allow combined Doppler correction and data detection with no penalty due to intersymbol interference (ISI). The effects of ISI due to timing jitter are assessed by computer simulation.

  14. Compression of polyphase codes with Doppler shift

    NASA Astrophysics Data System (ADS)

    Wirth, W. D.

    It is shown that pulse compression with sufficient Doppler tolerance may be achieved with polyphase codes derived from linear frequency modulation (LFM) and nonlinear frequency modulation (NLFM). Low sidelobes in range and Doppler are required especially for the radar search function. These may be achieved by an LFM derived phase coder together with Hamming weighting or by applying a PNL polyphase code derived from NLFM. For a discrete and known Doppler frequency with an expanded and mismatched reference vector a sidelobe reduction is possible. The compression is then achieved without a loss in resolution. A set up for the expanded reference gives zero sidelobes only in an interval around the signal peak or a least square minimization for all range elements. This version may be useful for target tracking.

  15. Doppler effect in Schwarzschild and Kerr geometries

    NASA Astrophysics Data System (ADS)

    Radosz, A.; Augousti, A. T.; Ostasiewicz, K.

    2008-03-01

    Calculation of the Doppler shift in general relativity involves contributions of gravitational and kinematical origins and for most metrics or trajectories these contributions are coupled. The exact expression for this Doppler shift may simplify for particular symmetries. Here the specific case for a light signal emitted by a distant inertial observer and received by an in-falling observer in a Schwarzschild geometry is discussed. The resulting expression the Doppler shift is composed of simple factors that can be clearly identified with contributions arising from classical kinematical, special relativistic and general relativistic origins. This result turns out to be more general and it holds for a case of an arbitrary radial in-fall in Schwarzschild geometry and for a particular type of in-fall in the case of a Kerr metric.

  16. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    NASA Technical Reports Server (NTRS)

    Roberts, W. T.

    1985-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  17. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    NASA Technical Reports Server (NTRS)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  18. Doppler experiments with Cassini radio system

    NASA Technical Reports Server (NTRS)

    Comoretto, G.; Bertotti, B.; Iess, L.; Ambrosini, R.

    1992-01-01

    The radio system of the Cassini orbiter will include a K-alpha band downlink channel, mainly intended for telemetry. A K-alpha uplink has also been proposed to allow for a highly accurate gravitational wave experiment. The fourfold increase in frequency will reduce the plasma noise by a factor of 12 and will allow a Doppler accuracy better than 10 exp -15 for time scales of 10 exp 3 - 10 exp 4 s. Extensive Doppler measurements of the gravitational field of Saturn and its satellites can be performed, exploiting the induced change in the velocity of the spacecraft. Possible sources of low-frequency gravitational waves and errors in the Doppler link are discussed.

  19. Inline Ultrasonic Rheometry by Pulsed Doppler

    SciTech Connect

    Pfund, David M.; Greenwood, Margaret S.; Bamberger, Judith A.; Pappas, Richard A.

    2006-12-22

    This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning, thixotropic gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).

  20. Effects of transducer, velocity, Doppler angle, and instrument settings on the accuracy of color Doppler ultrasound.

    PubMed

    Stewart, S F

    2001-04-01

    The accuracy of a commercial color Doppler ultrasound (US) system was assessed in vitro using a rotating torus phantom. The phantom consisted of a thin rubber tube filled with a blood-mimicking fluid, joined at the ends to form a torus. The torus was mounted on a disk suspended in water, and rotated at constant speeds by a motor. The torus fluid was shown in a previous study to rotate as a solid body, so that the actual fluid velocity was dependent only on the motor speed and sample volume radius. The fluid velocity could, thus, be easily compared to the color Doppler-derived velocity. The effects of instrument settings, velocity and the Doppler angle was assessed in four transducers: a 2.0-MHz phased-array transducer designed for cardiac use, a 4.0-MHz curved-array transducer designed for general thoracic use, and two linear transducers designed for vascular use (one 4.0 MHz and one 6.0 MHz). The color Doppler accuracy was found to be significantly dependent on the transducer used, the pulse-repetition frequency and wall-filter frequency, the actual fluid velocity and the Doppler angle (p < 0.001 by analysis of variance). In particular, the phased array and curved array were observed to be significantly more accurate than the two linear arrays. The torus phantom was found to provide a sensitive measure of color Doppler accuracy. Clinicians need to be aware of these effects when performing color Doppler US exams.

  1. Broad-band acoustic Doppler current profiler

    USGS Publications Warehouse

    Cobb, E.D.

    1993-01-01

    The broad-band acoustic Doppler current profiler is an instrument that determines velocity based on the Doppler principle by reflecting acoustic signals off sediment particles in the water. The instrument is capable of measuring velocity magnitude and direction throughout a water column and of measuring water depth. It is also capable of bottom tracking and can, therefore, keep track of its own relative position as it is moved across a channel. Discharge measurements can be made quickly and, based on limited tests, accurately with this instrument. ?? 1993.

  2. Laser Doppler distance sensor using phase evaluation.

    PubMed

    Günther, P; Pfister, T; Büttner, L; Czarske, J

    2009-02-16

    This paper presents a novel optical sensor which allows simultaneous measurements of axial position and tangential velocity of moving solid state objects. An extended laser Doppler velocimeter setup is used with two slightly tilted interference fringe systems. The distance to a solid state surface can be determined via a phase evaluation. The phase laser Doppler distance sensor offers a distance resolution of 150 nm and a total position uncertainty below 1 microm. Compared to conventional measurement techniques, such as triangulation, the distance resolution is independent of the lateral surface velocity. This advantage enables precise distance and shape measurements of fast rotating surfaces.

  3. Development of Doppler Global Velocimeter (DGV)

    DTIC Science & Technology

    1998-05-01

    Dissertation, Wichita State University, May, 1995. Q«M?7 A301 ’ E’ a’IdI MilleI’ L; S-’ "Eva,uation of a Basic Doppler Global Velocimetry System," SAE...200 words) A two-component Doppler Global Velocimeter (DGV) and a two-component Point Doppier Velocimeter (PDV) are descried Velocity measurements...for both systems to quantify accuracy are presented. Results are presented for velocity distributions over the surface of a rotating wheel and fully

  4. Laser Doppler And Range Systems For Spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, P. W.; Gagliardi, R. M.

    1990-01-01

    Report discusses two types of proposed laser systems containing active transponders measuring distance (range) and line-of-sight velocity (via Doppler effect) between deep space vehicle and earth-orbiting satellite. Laser system offers diffraction advantage over microwave system. Delivers comparable power to distant receiver while using smaller transmitting and receiving antennas and less-powerful transmitter. Less subject to phase scintillations caused by passage through such inhomogeneous media as solar corona. One type of system called "incoherent" because range and Doppler measurements do not require coherence with laser carrier signals. Other type of system called "coherent" because successful operation requires coherent tracking of laser signals.

  5. Ultrasonographic Doppler Use for Female Reproduction Management.

    PubMed

    Bollwein, Heinrich; Heppelmann, Maike; Lüttgenau, Johannes

    2016-03-01

    Transrectal color Doppler ultrasonography is a useful technique to get new information about physiologic and pathophysiologic alterations of the uterus and ovaries in female cattle. During all reproductive stages characteristic changes in uterine blood flow are observed. Cows with puerperal disturbances show delayed decrease in uterine blood flow in the first few weeks postparturition compared with healthy cows. Measurement of follicular blood flow is used to identify normally developing follicles and predict superovulatory response. Determination of luteal blood is more reliable than B-mode sonography to distinguish between functional and nonfunctional corpora lutea. Color Doppler ultrasonography is a promising tool to improve reproductive management in female cattle.

  6. Laser Doppler velocimeter aerial spray measurements

    NASA Technical Reports Server (NTRS)

    Zalay, A. D.; Eberle, W. R.; Howle, R. E.; Shrider, K. R.

    1978-01-01

    An experimental research program for measuring the location, spatial extent, and relative concentration of airborne spray clouds generated by agricultural aircraft is described. The measurements were conducted with a ground-based laser Doppler velocimeter. The remote sensing instrumentation, experimental tests, and the results of the flight tests are discussed. The cross section of the aerial spray cloud and the observed location, extent, and relative concentration of the airborne particulates are presented. It is feasible to use a mobile laser Doppler velocimeter to track and monitor the transport and dispersion of aerial spray generated by an agricultural aircraft.

  7. Velocity precision measurements using laser Doppler anemometry

    NASA Astrophysics Data System (ADS)

    Dopheide, D.; Taux, G.; Narjes, L.

    1985-07-01

    A Laser Doppler Anemometer (LDA) was calibrated to determine its applicability to high pressure measurements (up to 10 bars) for industrial purposes. The measurement procedure with LDA and the experimental computerized layouts are presented. The calibration procedure is based on absolute accuracy of Doppler frequency and calibration of interference strip intervals. A four-quadrant detector allows comparison of the interference strip distance measurements and computer profiles. Further development of LDA is recommended to increase accuracy (0.1% inaccuracy) and to apply the method industrially.

  8. Photoacoustic Doppler flow measurement in optically scattering media

    NASA Astrophysics Data System (ADS)

    Fang, Hui; Maslov, Konstantin; Wang, Lihong V.

    2007-12-01

    We recently observed the photoacoustic Doppler effect from flowing small light-absorbing particles. Here, we apply the effect to measure blood-mimicking fluid flow in an optically scattering medium. The light scattering in the medium decreases the amplitude of the photoacoustic Doppler signal but does not affect either the magnitude or the directional discrimination of the photoacoustic Doppler shift. This technology may hold promise for a new Doppler method for measuring blood flow in microcirculation with high sensitivity.

  9. Method for Canceling Ionospheric Doppler Effect

    NASA Technical Reports Server (NTRS)

    Vessot, R. F. C.

    1982-01-01

    Unified transponder system with hydrogen-maser oscillators at both stations can compensate for both motional and ionospheric components of Doppler shift. Appropriate choices of frequency shift in output of mixer m3. System exploits proportionality between dispersive component of frequency shift and reciprocal of frequency to achieve cancellation of dispersive component at output.

  10. Calculating "g" from Acoustic Doppler Data

    ERIC Educational Resources Information Center

    Torres, Sebastian; Gonzalez-Espada, Wilson J.

    2006-01-01

    Traditionally, the Doppler effect for sound is introduced in high school and college physics courses. Students calculate the perceived frequency for several scenarios relating a stationary or moving observer and a stationary or moving sound source. These calculations assume a constant velocity of the observer and/or source. Although seldom…

  11. Rubidium Atomic Line Filtered (RALF) Doppler Velocimetry

    NASA Astrophysics Data System (ADS)

    Fajardo, Mario; Molek, Christopher; Vesely, Annamaria

    2015-06-01

    We report the successful proof-of-concept demonstration of the Rubidium Atomic Line Filtered (RALF) Doppler velocimetry technique. RALF is a high-velocity and high-acceleration adaptation of the Global Doppler Velocimetry (GDV) method developed in the 1990s by aerodynamics researchers. Laser velocimetry techniques in common use within the shock physics community (e . g . VISAR, Fabry-Perot, PDV) decode the Doppler shift of light reflected from a moving surface via interference phenomena. In contrast, RALF employs a completely different physical principle: the frequency-dependent near-resonant optical transmission of a Rb/N2 gas cell, to convert the Doppler shift of reflected λ0 ~ 780.24 nm light directly into transmitted light intensity. The single-point RALF apparatus used in these experiments is fiber optic based, and incorporates a simultaneous PDV measurement channel as an ``internal standard'' for validation of the RALF results. Future plans include ``line-RALF'' experiments with streak camera detection, and two-dimensional surface velocity mapping using pulsed laser illumination and gated intensified CCD camera detection. [RW PA#4931

  12. Investigations of Near-Zone Doppler Effects.

    NASA Astrophysics Data System (ADS)

    Prouty, Dale Austen

    Far away from an electromagnetic source the normal Doppler shifts in frequency occur--a red shift for receding and a blue shift for approaching. As indicated by previous work with an infinitesimal dipole, different frequency shifts occur when the source and observer move closer together, into the near-zone. These "near-zone Doppler effects" are investigated for general sources and subsequently two specific examples are presented. The general results show that near-zone shifts are similar to far-zone shifts, but the local phase velocity must be used, i.e. (DIAGRAM, TABLE OR GRAPHIC OMITTED...PLEASE SEE DAI). In the far zone the phase velocity is the speed of light; in the near zone it differs. Fundamentally, the distance between surfaces of constant phase in the near zone is changed. The surfaces of constant phase for the waves are no longer spherical, but more ellipsoidal or spheroidal, so that a moving observer sees a different frequency shift. Two specific examples are presented to indicate the actual magnitude of near-zone effects. The examples include a prolate spheroidal antenna and a circular aperture. Once the magnitude of the effects is determined, the measurability of near-zone Doppler effects is discussed. The investigation concentrates on Fresnel zone effects due to the measurement problem. Finally, it is shown that for an electrically large wire antenna (the spheroidal example) near-zone Doppler effects are measurable.

  13. Adaptive Spectral Envelope Estimation for Doppler Ultrasound.

    PubMed

    Kathpalia, Aditi; Karabiyik, Yucel; Eik-Nes, Sturla; Tegnander, Eva; Ekroll, Ingvild; Kiss, Gabriel; Torp, Hans

    2016-07-07

    Estimation of accurate maximum velocities and spectral envelope in ultrasound Doppler blood flow spectrograms are both essential for clinical diagnostic purposes. However, obtaining accurate maximum velocity is not straightforward due to intrinsic spectral broadening and variance in the power spectrum estimate. The method proposed in this work for maximum velocity point detection has been developed by modifying an existing method - Signal Noise Slope Intersection (SNSI), incorporating in it steps from an altered version of another method called Geometric Method (GM). Adaptive noise estimation from the spectrogram ensures that a smooth spectral envelope is obtained post detection of these maximum velocity points. The method has been tested on simulated Doppler signal with scatterers possessing a parabolic flow velocity profile constant in time, steady and pulsatile string phantom recordings as well as in vivo recordings from uterine, umbilical, carotid and subclavian arteries. Results from simulation experiments indicate a bias of less than 2.5% in maximum velocities when estimated for a range of peak velocities, Doppler angles and SNR levels. Standard deviation in the envelope is low - less than 2% in case of experiments done by varying the peak velocity and Doppler angle for steady phantom and simulated flow; and also less than 2% in case of experiments done by varying SNR but keeping constant flow conditions for in vivo and simulated flow. Low variability in the envelope makes the prospect of using the envelope for automated blood flow measurements possible and is illustrated for the case of Pulsatility Index estimation in uterine and umbilical arteries.

  14. Tissue Doppler imaging reproducibility during exercise.

    PubMed

    Bougault, V; Nottin, S; Noltin, S; Doucende, G; Obert, P

    2008-05-01

    Tissue Doppler imaging (TDI) is an echocardiographic technique used during exercising to improve the accuracy of a cardiovascular diagnostic. The validity of TDI requires its reproducibility, which has never been challenged during moderate to maximal intensity exercising. The present study was specifically designed to assess the transmitral Doppler and pulsed TDI reproducibility in 19 healthy men, who had undergone two identical semi-supine maximal exercise tests on a cycle ergometer. Systolic (S') and diastolic (E') tissue velocities at the septal and lateral walls as well as early transmitral velocities (E) were assessed during exercise up to maximal effort. The data were compared between the two tests at 40 %, 60 %, 80 % and 100 % of maximal aerobic power. Despite upper body movements and hyperventilation, good quality echocardiographic images were obtained in each case. Regardless of exercise intensity, no differences were noticed between the two tests for all measurements. The variation coefficients for Doppler variables ranged from 3 % to 9 % over the transition from rest to maximal exercise. The random measurement error was, on average, 5.8 cm/s for E' and 4.4 cm/s for S'. Overall, the reproducibility of TDI was acceptable. Tissue Doppler imaging can be used to accurately evaluate LV diastolic and/or systolic function for this range of exercise intensity.

  15. Satellite Doppler data processing using a microcomputer

    NASA Technical Reports Server (NTRS)

    Schmid, P. E.; Lynn, J. J.

    1977-01-01

    A microcomputer which was developed to compute ground radio beacon position locations using satellite measurements of Doppler frequency shift is described. Both the computational algorithms and the microcomputer hardware incorporating these algorithms were discussed. Results are presented where the microcomputer in conjunction with the NIMBUS-6 random access measurement system provides real time calculation of beacon latitude and longitude.

  16. Tissue Doppler imaging in cardiac sarcoidosis.

    PubMed

    Smedema, J P

    2008-07-01

    A middle-aged African lady, who presented with ventricular tachycardias, mitral valve regurgitation and congestive heart failure, was diagnosed with cardiac sarcoidosis. Tissue Doppler imaging demonstrated abnormalities suggestive of myocardial scar, which was confirmed by contrast-enhanced cardiac magnetic resonance.

  17. Acoustic Doppler discharge-measurement system

    USGS Publications Warehouse

    Simpson, Michael R.; Oltmann, Richard N.; ,

    1990-01-01

    A discharge-measurement system that uses a vessel-mounted acoustic Doppler current profiler has been developed and tested by the U.S. Geological Survey. Discharge measurements using the system require a fraction of the time needed for conventional current-meter discharge measurements and do not require shore-based navigational aids or tag lines for positioning the vessel.

  18. A MAGNETIC CALIBRATION OF PHOTOSPHERIC DOPPLER VELOCITIES

    SciTech Connect

    Welsch, Brian T.; Fisher, George H.; Sun, Xudong

    2013-03-10

    The zero point of measured photospheric Doppler shifts is uncertain for at least two reasons: instrumental variations (from, e.g., thermal drifts); and the convective blueshift, a known correlation between intensity and upflows. Accurate knowledge of the zero point is, however, useful for (1) improving estimates of the Poynting flux of magnetic energy across the photosphere, and (2) constraining processes underlying flux cancellation, the mutual apparent loss of magnetic flux in closely spaced, opposite-polarity magnetogram features. We present a method to absolutely calibrate line-of-sight (LOS) velocities in solar active regions (ARs) near disk center using three successive vector magnetograms and one Dopplergram coincident with the central magnetogram. It exploits the fact that Doppler shifts measured along polarity inversion lines (PILs) of the LOS magnetic field determine one component of the velocity perpendicular to the magnetic field, and optimizes consistency between changes in LOS flux near PILs and the transport of transverse magnetic flux by LOS velocities, assuming that ideal electric fields govern the magnetic evolution. Previous calibrations fitted the center-to-limb variation of Doppler velocities, but this approach cannot, by itself, account for residual convective shifts at the limb. We apply our method to vector magnetograms of AR 11158, observed by the Helioseismic and Magnetic Imager aboard the Solar Dynamics Observatory, and find clear evidence of offsets in the Doppler zero point in the range of 50-550 m s{sup -1}. In addition, we note that a simpler calibration can be determined from an LOS magnetogram and Dopplergram pair from the median Doppler velocity among all near-disk-center PIL pixels. We briefly discuss shortcomings in our initial implementation, and suggest ways to address these. In addition, as a step in our data reduction, we discuss the use of temporal continuity in the transverse magnetic field direction to correct apparently

  19. Rubidium atomic line filtered (RALF) Doppler velocimetry

    NASA Astrophysics Data System (ADS)

    Fajardo, Mario E.; Molek, Christopher D.; Vesely, Annamaria L.

    2017-01-01

    We report recent improvements to our Rubidium Atomic Line Filtered (RALF) Doppler velocimetry apparatus [M.E. Fajardo, C.D. Molek, and A.L. Vesely, J. Appl. Phys. 118, 144901 (2015)]. RALF is a high-velocity and high-acceleration adaptation of the Doppler Global Velocimetry method for measuring multi-dimensional velocity vector flow fields, which was developed in the 1990s by aerodynamics researchers [H. Komine, U.S. Patent #4,919,536]. Laser velocimetry techniques in common use within the shock physics community (e.g. VISAR, Fabry-Pérot, PDV) decode the Doppler shift of light reflected from a moving surface via interference phenomena. In contrast, RALF employs a completely different physical principle: the frequency-dependent near-resonant optical transmission of a Rb/N2 gas cell, to encode the Doppler shift of reflected λ0 ≈ 780.24 nm light directly onto the transmitted light intensity. Thus, RALF is insensitive to minor changes to the optical pathlengths and transit times of the Doppler shifted light, which promises a number of practical advantages in imaging velocimetry applications. The single-point RALF proof-of-concept apparatus described here is fiber optic based, and our most recent modifications include the incorporation of a larger bandwidth detection system, and a second 780 nm laser for simultaneous upshifted-PDV (UPDV) measurements. We report results for the laser driven launch of a 10-μm-thick aluminum flyer which show good agreement between the RALF and UPDV velocity profiles, within the limitations of the admittedly poor signal:noise ratio (SNR) RALF data.

  20. The Novel Nonlinear Adaptive Doppler Shift Estimation Technique and the Coherent Doppler Lidar System Validation Lidar

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y.; Koch, Grady J.

    2006-01-01

    The signal processing aspect of a 2-m wavelength coherent Doppler lidar system under development at NASA Langley Research Center in Virginia is investigated in this paper. The lidar system is named VALIDAR (validation lidar) and its signal processing program estimates and displays various wind parameters in real-time as data acquisition occurs. The goal is to improve the quality of the current estimates such as power, Doppler shift, wind speed, and wind direction, especially in low signal-to-noise-ratio (SNR) regime. A novel Nonlinear Adaptive Doppler Shift Estimation Technique (NADSET) is developed on such behalf and its performance is analyzed using the wind data acquired over a long period of time by VALIDAR. The quality of Doppler shift and power estimations by conventional Fourier-transform-based spectrum estimation methods deteriorates rapidly as SNR decreases. NADSET compensates such deterioration in the quality of wind parameter estimates by adaptively utilizing the statistics of Doppler shift estimate in a strong SNR range and identifying sporadic range bins where good Doppler shift estimates are found. The authenticity of NADSET is established by comparing the trend of wind parameters with and without NADSET applied to the long-period lidar return data.

  1. Phase tracking for pulsar navigation with Doppler frequency

    NASA Astrophysics Data System (ADS)

    Xinyuan, Zhang; Ping, Shuai; Liangwei, Huang

    2016-12-01

    Doppler frequency in pulsar navigation is an effect caused by spacecraft and pulsar motion, which would worsen the pulsar navigation accuracy. To describe this influence, we establish the Doppler frequency measurement model based on pulsar timing. With this model, we describe the relationship between the phase estimation performance and the observation time when Doppler frequency exists. To reduce the pulsar navigation error due to the Doppler frequency, we designed the phase tracking loop for the pulsar navigation. The pulsar frequency can be modified before the phase estimation. As a result, the impact of the Doppler frequency could be lessened, and the observation interval lengths can be lengthened to improve the phase estimation performance.

  2. Superharmonic microbubble Doppler effect in ultrasound therapy.

    PubMed

    Pouliopoulos, Antonios N; Choi, James J

    2016-08-21

    The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5  ×  10(4)-5  ×  10(7) microbubbles ml(-1)) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s(-1), prior to the onset

  3. Superharmonic microbubble Doppler effect in ultrasound therapy

    NASA Astrophysics Data System (ADS)

    Pouliopoulos, Antonios N.; Choi, James J.

    2016-08-01

    The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5  ×  104-5  ×  107 microbubbles ml-1) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s-1, prior to the onset of

  4. Normal Echocardiographic Measurements in a Korean Population Study: Part II. Doppler and Tissue Doppler Imaging

    PubMed Central

    Choi, Jin-Oh; Shin, Mi-Seung; Kim, Mi-Jeong; Jung, Hae Ok; Park, Jeong Rang; Sohn, Il Suk; Kim, Hyungseop; Park, Seong-Mi; Yoo, Nam Jin; Choi, Jung Hyun; Kim, Hyung-Kwan; Cho, Goo-Yeong; Lee, Mi-Rae; Park, Jin-Sun; Shim, Chi Young; Kim, Dae-Hee; Shin, Dae-Hee; Shin, Gil Ja; Shin, Sung Hee; Kim, Kye Hun; Park, Jae-Hyeong; Lee, Sang Yeub; Kim, Woo-Shik

    2016-01-01

    Background Hemodynamic and functional evaluation with Doppler and tissue Doppler study as a part of comprehensive echocardiography is essential but normal reference values have never been reported from Korean normal population especially according to age and sex. Methods Using Normal echOcaRdiographic Measurements in a KoreAn popuLation study subjects, we obtained normal reference values for Doppler and tissue Doppler echocardiography including tricuspid annular velocities according to current guidelines and compared values according to gender and age groups. Results Mitral early diastolic (E) and late diastolic (A) velocity as well as E/A ratio were significantly higher in women compared to those in men. Conversely, mitral peak systolic and late diastolic annular velocity in both septal and lateral mitral annulus were significantly lower in women compared to those in men. However, there were no significant differences in both septal and lateral mitral early diastolic annular (e') velocity between men and women. In both men and women, mitral E velocity and its deceleration time as well as both E/A and E/e' ratio considerably increased with age. There were no significant differences in tricuspid inflow velocities and tricuspid lateral annular velocities between men and women except e' velocity, which was significantly higher in women compared to that in men. However, changes in both tricuspid inflow and lateral annular velocities according to age were similar to those in mitral velocities. Conclusion Since there were significant differences in Doppler and tissue Doppler echocardiographic variables between men and women and changes according to age were even more considerable in both gender groups, normal Doppler echocardiographic values should be differentially applied based on age and sex. PMID:27358707

  5. Design of a Doppler reflectometer for KSTAR

    SciTech Connect

    Lee, K. D. Nam, Y. U.; Seo, Seong-Heon; Kim, Y. S.

    2014-11-15

    A Doppler reflectometer has been designed to measure the poloidal propagation velocity on the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. It has the operating frequency range of V-band (50-75 GHz) and the monostatic antenna configuration with extraordinary mode (X-mode). The single sideband modulation with an intermediate frequency of 50 MHz is used for the heterodyne measurement with the 200 MHz in-phase and quadrature (I/Q) phase detector. The corrugated conical horn antenna is used to approximate the Gaussian beam propagation and it is installed together with the oversized rectangular waveguides in the vacuum vessel. The first commissioning test of the Doppler reflectometer system on the KSTAR tokamak is planned in the 2014 KSTAR experimental campaign.

  6. Analysis of Doppler measurements of people

    NASA Astrophysics Data System (ADS)

    Tan, Robert; Bender, Robert

    2006-05-01

    With the changing nature of international security it is of interest to the military to use remote sensors to detect and classify people as potential threats. We chose a millimeter wave (MMW) radar as our sensor to collect data on single and small groups of people that were either walking or running to determine how easily they could be detected. This work was done to support the concept of using Ka-band radar to detect people from an airborne platform. Fully-polarimetric Ka-Band radar data was collected of people walking and running at various orientations with respect to the radar. Micro-Doppler analysis reveals Doppler oscillations with time that are characteristic of people at all orientations measured.

  7. ROTATIONAL DOPPLER BEAMING IN ECLIPSING BINARIES

    SciTech Connect

    Groot, Paul J.

    2012-01-20

    In eclipsing binaries the stellar rotation of the two components will cause a rotational Doppler beaming during eclipse ingress and egress when only part of the eclipsed component is covered. For eclipsing binaries with fast spinning components this photometric analog of the well-known spectroscopic Rossiter-McLaughlin effect can exceed the strength of the orbital effect. Example light curves are shown for a detached double white dwarf binary, a massive O-star binary and a transiting exoplanet case, similar to WASP-33b. Inclusion of the rotational Doppler beaming in eclipsing systems is a prerequisite for deriving the correct stellar parameters from fitting high-quality photometric light curves and can be used to determine stellar obliquities as well as, e.g., an independent measure of the rotational velocity in those systems that may be expected to be fully synchronized.

  8. Scrotal inflammatory disease: color Doppler US findings.

    PubMed

    Horstman, W G; Middleton, W D; Melson, G L

    1991-04-01

    A study of 45 patients with 51 cases of hemiscrotal inflammatory disease was done to determine the color Doppler ultrasonographic appearance of scrotal inflammatory disorders. The diagnosis was ultimately established by means of appropriate response to antibiotic treatment (47 cases) or surgery (four cases). In all cases, there was evidence of hyperemia: an increased number and concentration of detectable vessels in the affected portion of the scrotum. In 17 cases, the gray scale images were normal, and the only evidence of inflammation was the presence of hypervascularity. Abnormally decreased epididymal vascular resistance was detected in 14 cases of epididymitis; abnormally decreased testicular vascular resistance was detected in six cases of orchitis. Spontaneous venous flow was present in 18 patients. The authors conclude that color Doppler can demonstrate the hyperemic response to scrotal inflammatory disease and that, in the proper clinical setting, it can supplement the gray scale findings and increase diagnostic confidence.

  9. Intracoronary Doppler: Clinical Application And Future Directions

    NASA Astrophysics Data System (ADS)

    Whitlow, Patrick L.; Raymond, Russell E.; Tuzcu, E. Murat

    1989-08-01

    Because coronary arteriography may underestimate the severity of coronary artery disease, other methods to assess the physiologic significance of a coronary lesion have been sought. Experimental data have confirmed that the ratio of peak flow to resting flow, coronary vasodilator reserve (CVDR), is a quantitative measure of the functional significance of a coronary a stenosis. A 20 MHz pulsed Doppler catheter with a 1 mm outer diameter and an innerlumen for guidewire placement was developed in 1985 and has been used for clinical measurement of CVDR. The technique appears safe, and reliable signals can be obtained in the vast majority of patients studied. Limitations of the technique include possible changes in vessel diameter with delivery of a vasodilator stimulus, possible elevation of baseline flow above normal resting values which would diminish the CVDR, and inability to measure absolute coronary flow. These limitations could be overcome by the development of an intravascular Echo-Doppler device in the future.

  10. [Color-Doppler semiology in transplanted kidney].

    PubMed

    Rivolta, R; Castagnone, D; Burdick, L; Mandelli, C; Mangiarotti, R

    1993-05-01

    Color-encoded duplex ultrasonography (CEDU) makes a more accurate technique in kidney graft monitoring by combining real-time US with pulsed Doppler studies of renal vasculature. It is a non-invasive and easy technique. Suitable to study the whole renal artery and vein, CEDU also allows the qualitative and quantitative assessment of the intrarenal vasculature and therefore the easy diagnosis of such vessel dysfunctions as arteriovenous fistulas following biopsy. Moreover, Doppler spectral analysis can be used to distinguish among different causes of renal allograft dysfunction--i.e. rejection, cyclosporine nephrotoxicity or acute tubular necrosis. The value of the resistive index for the differential diagnosis is discussed. CEDU allows a more reliable measurement of renal blood flow thanks to the more precise evaluation of renal artery diameter and mean flow velocity.

  11. Doppler Lidar Wind Value-Added Product

    SciTech Connect

    Newsom, R. K.; Sivaraman, C.; Shippert, T. R.; Riihimaki, L. D.

    2015-07-01

    Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

  12. Adaptive Spectral Envelope Estimation for Doppler Ultrasound.

    PubMed

    Kathpalia, Aditi; Karabiyik, Yucel; Eik-Nes, Sturla H; Tegnander, Eva; Ekroll, Ingvild Kinn; Kiss, Gabriel; Torp, Hans

    2016-11-01

    Estimation of accurate maximum velocities and spectral envelope in ultrasound Doppler blood flow spectrograms are both essential for clinical diagnostic purposes. However, obtaining accurate maximum velocity is not straightforward due to intrinsic spectral broadening and variance in the power spectrum estimate. The method proposed in this paper for maximum velocity point detection has been developed by modifying an existing method-signal noise slope intersection, incorporating in it steps from an altered version of another method called geometric method. Adaptive noise estimation from the spectrogram ensures that a smooth spectral envelope is obtained postdetection of these maximum velocity points. The method has been tested on simulated Doppler signal with scatterers possessing a parabolic flow velocity profile constant in time, steady and pulsatile string phantom recordings, as well as in vivo recordings from uterine, umbilical, carotid, and subclavian arteries. The results from simulation experiments indicate a bias of less than 2.5% in maximum velocities when estimated for a range of peak velocities, Doppler angles, and SNR levels. Standard deviation in the envelope is low-less than 2% in the case of experiments done by varying the peak velocity and Doppler angle for steady phantom and simulated flow, and also less than 2% in the case of experiments done by varying SNR but keeping constant flow conditions for in vivo and simulated flow. Low variability in the envelope makes the prospect of using the envelope for automated blood flow measurements possible and is illustrated for the case of pulsatility index estimation in uterine and umbilical arteries.

  13. Sub miniaturized laser doppler velocimeter sensor

    NASA Technical Reports Server (NTRS)

    Gharib, Morteza (Inventor); Modaress, Darius (Inventor); Taugwalder, Frederic (Inventor)

    2003-01-01

    A miniaturized laser Doppler velocimeter is formed in a housing that is preferably 3 mm in diameter or less. A laser couples light to a first diffractive optical element that is formed on the fiber end. The light is coupled to a lens that also includes a diffractive optical element. The same lens is also used to collect receive light, and receives includes another diffractive optical element to collect that received light.

  14. Doppler Lidar for Wind Measurements on Venus

    NASA Technical Reports Server (NTRS)

    Singh, Upendra N.; Emmitt, George D.; Yu, Jirong; Kavaya, Michael J.

    2010-01-01

    NASA Langley Research Center has a long history of developing 2-micron laser transmitter for wind sensing. With support from NASA Laser Risk Reduction Program (LRRP) and Instrument Incubator Program (IIP), NASA Langley Research Center has developed a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement. The transmitter portion of the transceiver employs the high-pulse-energy, Ho:Tm:LuLiF, partially conductively cooled laser technology developed at NASA Langley. The transceiver is capable of 250 mJ pulses at 10 Hz. It is very similar to the technology envisioned for coherent Doppler lidar wind measurements from Earth and Mars orbit. The transceiver is coupled to the large optics and data acquisition system in the NASA Langley VALIDAR mobile trailer. The large optics consists of a 15-cm off-axis beam expanding telescope, and a full-hemispheric scanner. Vertical and horizontal vector winds are measured, as well as relative backscatter. The data acquisition system employs frequency domain velocity estimation and pulse accumulation. It permits real-time display of the processed winds and archival of all data. This lidar system was recently deployed at Howard University facility in Beltsville, Mary-land, along with other wind lidar systems. Coherent Doppler wind lidar ground-based wind measurements and comparisons with other sensors will be presented. A simulation and data product for wind measurement at Venus will be presented.

  15. Velocity variability in ultrasonic Doppler examinations.

    PubMed

    Hadlock, Jean; Beach, Kirk W

    2009-06-01

    Ultrasonic Doppler examination with spectral waveform has been used for the classification and surveillance of carotid artery stenosis for over 25 years. Progression/regression between examinations can be identified with 95% confidence if the velocity measurements change by more than two times the root mean square difference (RMSD) of the repeat measurement. Peak systolic velocity and end diastolic velocity measurements at a Doppler angle of 60 degrees were repeated in 47 carotid examinations. Measurement difference between sonographers and between instruments was tabulated. Root mean square difference was 11 cm/s (RMS%D = 11%) for systolic and 7 cm/s (RMS%D = 21%) for diastolic velocity measurements (excluding one severe stenosis case). Results for differences between sonographers and between instruments were similar to the overall results. In serial arterial studies using this Doppler velocimetry method, a difference exceeding 23 cm/s (21%) systolic, or 14 cm/s (42%) diastolic velocity indicates a significant (2 x RMSD) hemodynamic change.

  16. Laser Doppler measurement techniques for spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.; Gagliardi, Robert M.

    1986-01-01

    Two techniques are proposed for using laser links to measure the relative radial velocity of two spacecraft. The first technique determines the relative radial velocity from a measurement of the two-way Doppler shift on a transponded radio-frequency subcarrier. The subcarrier intensity-modulates reciprocating laser beams. The second technique determines the relative radial velocity from a measurement of the two-way Doppler shift on an optical frequency carrier which is transponded between spacecraft using optical Costas loops. The first technique might be used in conjunction with noncoherent optical communications, while the second technique is compatible with coherent optical communications. The first technique simultaneously exploits the diffraction advantage of laser beams and the maturity of radio-frequency phase-locked loop technology. The second technique exploits both the diffraction advantage of laser beams and the large Doppler effect at optical frequencies. The second technique has the potential for greater accuracy; unfortunately, it is more difficult to implement since it involves optical Costas loops.

  17. Applications of Doppler ultrasound in clinical vascular disease

    NASA Technical Reports Server (NTRS)

    Barnes, R. W.; Hokanson, D. E.; Sumner, D. S.; Strandness, D. E., Jr.

    1975-01-01

    Doppler ultrasound has become the most useful and versatile noninvasive technique for objective evaluation of clinical vascular disease. Commercially available continuous-wave instruments provide qualitative and quantitative assessment of venous and arterial disease. Pulsed Doppler ultrasound was developed to provide longitudinal and transverse cross-sectional images of the arterial lumen with a resolution approaching that of conventional X-ray techniques. Application of Doppler ultrasound in venous, peripheral arterial, and cerebrovascular diseases is reviewed.

  18. How to Create and Manipulate Radar Range-Doppler Plots

    DTIC Science & Technology

    2014-12-01

    UNCLASSIFIED How to Create and Manipulate Radar Range–Doppler Plots Don Koks Cyber & Electronic Warfare Division Defence Science and Technology...to the approach taken in addressing the jamming task in a later report. We discuss in detail how a radar generates a range–Doppler plot , using a set...FOR PUBLIC RELEASE ii UNCLASSIFIED UNCLASSIFIED DSTO–TN–1386 How to Create and Manipulate Radar Range–Doppler Plots Executive Summary This report lays

  19. Doppler and speckle methods for diagnostics in dentistry

    NASA Astrophysics Data System (ADS)

    Ulyanov, Sergey S.; Lepilin, Alexander V.; Lebedeva, Nina G.; Sedykh, Alexey V.; Kharish, Natalia A.; Osipova, Yulia; Karpovich, Alexander

    2002-02-01

    The results of statistical analysis of Doppler spectra of scattered intensity, obtained from tissues of oral cavity membrane of healthy volunteers, are presented. The dependence of the spectral moments of Doppler signal on cutoff frequency is investigated. Some results of statistical analysis of Doppler spectra, obtained from tooth pulp of patients, are presented. New approach for monitoring of blood microcirculation in orthodontics is suggested. Influence of own noise of measuring system on formation of speckle-interferometric signal is studied.

  20. Eliminating Doppler Effects in Synthetic-Aperture Radar Optical Processors

    NASA Technical Reports Server (NTRS)

    Constantindes, N. J.; Bicknell, T. J.

    1984-01-01

    Pair of photodetectors generates correction signals. Instrument detects Doppler shifts in radar and corrects processing parameters so ambiguities caused by shifts not manifested as double or overlapping images.

  1. Reexamination of the Doppler effect through Maxwell's equations.

    PubMed

    Guo, Wei; Aktas, Yildirim

    2012-08-01

    In this work, the electric field emitted from a moving source, an electric point dipole, is analyzed for the purpose of illustrating the physics behind the Doppler effect. It is found that if the (translational) motion of the source is nonrelativistic, the Doppler effect is realized in two steps: the motion of the source first causes the dyadic Green function associated with the electric field to acquire an oscillation frequency in the far-field region of the source, and then the frequency leads to the Doppler effect. It is also demonstrated that the Doppler effect is observable only in the far-field region of the source.

  2. PRECISE DOPPLER MONITORING OF BARNARD'S STAR

    SciTech Connect

    Choi, Jieun; Marcy, Geoffrey W.; Howard, Andrew W.; Isaacson, Howard; McCarthy, Chris; Fischer, Debra A.; Johnson, John A.; Wright, Jason T.

    2013-02-20

    We present 248 precise Doppler measurements of Barnard's Star (Gl 699), the second nearest star system to Earth, obtained from Lick and Keck Observatories during the 25 years between 1987 and 2012. The early precision was 20 m s{sup -1} but was 2 m s{sup -1} during the last 8 years, constituting the most extensive and sensitive search for Doppler signatures of planets around this stellar neighbor. We carefully analyze the 136 Keck radial velocities spanning 8 years by first applying a periodogram analysis to search for nearly circular orbits. We find no significant periodic Doppler signals with amplitudes above {approx}2 m s{sup -1}, setting firm upper limits on the minimum mass (Msin i) of any planets with orbital periods from 0.1 to 1000 days. Using a Monte Carlo analysis for circular orbits, we determine that planetary companions to Barnard's Star with masses above 2 M {sub Circled-Plus} and periods below 10 days would have been detected. Planets with periods up to 2 years and masses above 10 M {sub Circled-Plus} (0.03 M {sub Jup}) are also ruled out. A similar analysis allowing for eccentric orbits yields comparable mass limits. The habitable zone of Barnard's Star appears to be devoid of roughly Earth-mass planets or larger, save for face-on orbits. Previous claims of planets around the star by van de Kamp are strongly refuted. The radial velocity of Barnard's Star increases with time at 4.515 {+-} 0.002 m s{sup -1} yr{sup -1}, consistent with the predicted geometrical effect, secular acceleration, that exchanges transverse for radial components of velocity.

  3. The feasibility of Doppler monitoring during EVA.

    PubMed

    Barer, A; Filipenkov, S; Katuntsev, V; Vogt, L; Wenzel, J

    1995-07-01

    During extravehicular activities (EVA) outside the spacecraft, astronauts have to work under reduced pressure in a space suit. This pressure reduction induces the risk of decompression sickness (DCS) by the formation of gas bubbles from excess nitrogen dissolved in the organism by breathing air at normal pressure. Under laboratory conditions the gas bubbles moving in the blood stream can be detected by the non-invasive ultrasonic Doppler method. By early detection of excessive bubble formation the development of DCS symptoms may be prevented by early application of preventative measures. The method could also be useful when applied in the space suit in order to compare the results of laboratory tests with operational results, because there is a discrepancy according to the DCS risk of laboratory experiments and actual EVA missions, where no symptoms have been reported yet. A prototype Doppler sensor has been developed and implemented in the Russian Orlan suit. To investigate the feasibility of this method under simulated space conditions, the equipment has been used in a series of 12 thermovacuum chamber tests with suited subjects, where intravenous bubble formation was compared to unsuited control experiments. In more than 50% of the suited tests good Doppler recordings could be achieved. In some cases with unsatisfying results the signal could be improved by breathholding. Although the results do not yet allow any conclusion about a possible difference between suited and unsuited subjects due to the small number of tests performed, the method proved its feasibility for use in EVA suits and should be further developed to enhance the safety of EVA procedures.

  4. Christian Doppler is 200 years young.

    PubMed

    Bollinger, Alfred; Partsch, Hugo

    2003-11-01

    Christian Doppler was born 200 years ago in Salzburg, Austria, on November 29, 1803, worked in Prague and Vienna and died 150 years ago in Venice. In an article of eight pages he described the principle, which made him famous. It appeared in 1842 with the exotic title: "On the Coloured Light of the Double Stars and Certain Other Stars of the Heaven". The validity of his principle for velocity measurement was confirmed by trumpet sounds produced on a train moving towards and away from the observer. Around 1960 Japanese scientists suggested that flow velocity in blood vessels could be determined by analysing the difference of frequency between emitted and backscattered ultrasound. Rushmer and coworkers built machines suitable for medicine in Seattle, where Eugene Strandness recognized their potential and applied them in first studies. In 1967 the technique jumped to Europe and started to be used worldwide. Already by using continuous wave ultrasound it was possible to diagnose occlusive disease of neck and limb arteries, venous thrombosis and valvular insufficiency with accuracy. Measurements of postestenotic ankle blood pressure were facilitated by Doppler sensing. Over the years more sophisticated instruments were developed. Pulsed emission of ultrasound waves opened a way to study flow velocity profiles across large vessels. By combining the method with A or B mode ultrasound blood flow could be quantified and finally perfused segments of blood vessels visualized. Duplex scanning in its simple and then in its colour coded version is nowadays the standard non-invasive technique that nobody would like to miss. Vascular territories like intracranial, renal and intestinal arteries can also be explored. For the assessment of microvascular flow in skin and mucosae laser Doppler instruments were introduced.

  5. Intrarenal Doppler Indices in Acute Ureteric Obstruction

    PubMed Central

    2014-01-01

    Context: Urolithiasis remains a major health problem despite advances in therapy. Obstruction results in an increase in pressure within the urinary tract, causing structural and physiologic changes. This study aimed to calculate the intra renal Resistivity Index (RI) of acutely obstructed kidney, to determine the significance of Resistivity Index Ratio (RIR) and difference in Resistivity Index of obstructed and contralateral non obstructed kidney. Materials and Methods: Prospective study with renal Doppler for patients presenting with acute unilateral ureteric obstruction. Seventy two patients between the age group 20-45 y presenting to the Department of Radiodiagnosis, between January – December 2006 with acute unilateral ureteric obstruction were included in the study. Gray scale and Doppler evaluation of the kidneys done; with assessment of the ureteric calculus. Renal Doppler indices calculated and follow up of the same done after relief of obstruction. Statistical Analysis: Statistical analysis was done using SPSS Software V13 and p-value <0.05 was considered as statistically significant. Results: Forty two patients (58.33%) had mild, 28 (38.89%) moderate and 2 (2.78%) severe hydronephrosis. The mean RI of the obstructed kidney was 0.66±0.88 and that of contralateral non obstructed kidney was 0.569±0.05. Delta RI between the obstructed and contralateral non obstructed kidney was 0.08±0.03. The mean RIR between the obstructed and non obstructed kidney was 1.12±0.04 and the same after relief of obstruction was 1.03±0.06. Conclusion: The intrarenal Resistivity indices are less sensitive indicators in predicting the diagnosis of acute ureteric obstruction, although Resistivity Index Ratio appears to be a better parameter. The indices within the normal range do not rule out the absence of obstruction. Hence these parameters should not be interpreted in isolation. PMID:25654006

  6. Detection of microemboli by transcranial Doppler ultrasound.

    PubMed Central

    Grosset, D G; Georgiadis, D; Kelman, A W; Cowburn, P; Stirling, S; Lees, K R; Faichney, A; Mallinson, A; Quin, R; Bone, I; Pettigrew, L; Brodie, E; MacKay, T; Wheatley, D J

    1996-01-01

    Doppler ultrasound detection of abnormally high-pitched signals within the arterial waveform offers a new method for diagnosis, and potentially for prediction, of embolic complications in at-risk patients. The nature of Doppler "microembolic" signals is of particular interest in patients with prosthetic heart valves, where a high prevalence of these signals is observed. Monitoring the middle cerebral artery with 2-MHz transcranial Doppler ultrasound (TC-2000, Nicolet Biomedical; Warwick, UK), we looked for microemboli signals in 150 patients (95 women and 55 men), and found 1 or more signals during a 30-min recording in 89% of 70 patients with Bjork-Shiley valves (principally monostrut), 54% of 50 patients with Medtronic-Hall valves, and 50% of 30 patients with Carpentier-Edwards valves (p < 0.001, chi 2). In the patients with Bjork-Shiley valves, the mean number of signals per hour was 59 (range, 42-86; 95% confidence interval), which was significantly higher than the mean in patients with Medtronic-Hall and Carpentier-Edwards valves (1.5[range, 0.5-2.5] and 1 [range, 0-5.3], respectively; both p < 0.04, multiple comparisons. Bonferroni correction). In the patients undergoing serial pre- and postoperative studies, the causative role of the valve implant was emphasized. There was no correlation between the number of emboli signals and a prior history of neurologic deficit, cardiac rhythm, previous cardiac surgery, or the intensity of oral anticoagulation, in patients with prosthetic heart valves. In Bjork-Shiley patients, dual (mitral and aortic) valves were associated with more signals than were single valves. In Medtronic-Hall patients, the signal count was greater for valves in the aortic position than it was for valves in the mitral position. Comparative studies of Doppler emboli signals in other clinical settings suggest a difference in composition or size of the underlying maternal between prosthetic valve patients and patients with carotid stenosis. These

  7. Catadioptric optics for laser Doppler velocimeter applications

    NASA Technical Reports Server (NTRS)

    Dunagan, Stephen E.

    1989-01-01

    This paper examines the adaptation of low-cost Schmidt-Cassegrain astronomical telescopes to perform the laser-beam-focusing and scattered-light collection tasks associated with dual-beam laser Doppler velocimetry. A generic telescope design is analyzed using ray-tracing methods and Gaussian beam-propagation theory. A straightforward modification procedure to convert from infinite to near unity conjugate-ratio operation with very low residual aberration is identified and tested with a 200-mm-aperture telescope modified for f/10 operation. Performance data for this modified telescope configuration are near the diffraction limit and agree well with predictions.

  8. Transmission media effects on precise Doppler tracking

    NASA Technical Reports Server (NTRS)

    Callahan, P. S.

    1978-01-01

    The effects of the transmission media - the earth's troposphere and ionosphere, and the solar wind - on precise Doppler tracking are discussed. The charged particle effects can be largely removed by dual frequency observations; however there are limitations to these corrections (besides system noise and/or finite integration times) including the effects of magnetic fields, diffraction, and differential refraction, all of which must be carefully evaluated. The earth's troposphere can contribute an error of delta f/f approximately 10 to the minus 14th power.

  9. The new Adelaide medium frequency Doppler radar

    NASA Astrophysics Data System (ADS)

    Reid, I. M.; Vandepeer, B. G. W.; Dillon, S.; Fuller, B.

    1993-08-01

    The Buckland Park Aerial Array (35 deg S, 138 deg E) is situated about 40 km north of Adelaide on a flat coastal plain. It was designed by Basil Briggs and Graham Elford, and constructed between 1965 and 1968. The first results were published in the late 1960's. Some aspects of the history of the array are described in Briggs (1993). A new MF Doppler Radar utilizing the array has been developed. This paper describes some of the technical details of this new facility.

  10. Applying Zeeman Doppler imaging to solar spectra

    NASA Astrophysics Data System (ADS)

    Hussain, G. A. J.; Saar, S. H.; Collier Cameron, A.

    2004-03-01

    A new generation of spectro-polarimeters with high throughput (e.g. CFHT/ESPADONS and LBT/PEPSI) is becoming available. This opportunity can be exploited using Zeeman Doppler imaging (ZDI), a technique that inverts time-series of Stokes V spectra to map stellar surface magnetic fields (Semel 1989). ZDI is assisted by ``Least squares deconvolution'' (LSD), which sums up the signal from 1000's of photospheric lines to produce a mean deconvolved profile with higher S:N (Donati & Collier Cameron 1997).

  11. Dealiasing Doppler velocites using edge detection

    NASA Astrophysics Data System (ADS)

    Meech, Scott P.

    This study presents a new algorithm to dealias folded Doppler velocities in S, C, and X-Band radars using a new boundary detection technique on the raw velocity field as a whole, rather than the traditional gate by gate methodology used in more popular and widespread algorithms. Several different types of precipitation events are used to compare and contrast the final output of the new boundary based algorithm. The results are then compared to the NEXRAD dealiasing algorithm as defined by Eilts and Smith (1989) and an objective manual unfolding by radar manipulation software called SoloII.

  12. Mobile fiber-optic laser Doppler anemometer.

    PubMed

    Stieglmeier, M; Tropea, C

    1992-07-20

    A laser Doppler anemometer (LDA) has been developed that combines the compactness and low power consumption of laser diodes and avalanche photodiodes with the flexibility and possibility of miniaturization by using fiber-optic probes. The system has been named DFLDA for laser diode fiber LDA and is especially suited for mobile applications, for example, in trains, airplanes, or automobiles. Optimization considerations of fiber-optic probes are put forward and several probe examples are described in detail. Measurement results from three typical applications are given to illustrate the use of the DFLDA. Finally, a number of future configurations of the DFLDA concept are discussed.

  13. Wideband infrared receiver backend. [Doppler radar, radiometers

    NASA Technical Reports Server (NTRS)

    Flattau, T.; Mellars, J.

    1974-01-01

    The design, operation, and configuration of the receiver backend for a wideband infrared tracking receiver are described. A squaring loop is incorporated into the receiver design to enable it to track the Doppler shifted carrier which is Phase Shift Keyed modulated. The receiver has a 400 MHz instantaneous bandwidth and tracks signals whose carrier frequency at the backend input is between 200 and 900 MHz with frequency variation rates greater than 20 MHz/second. The output data is compatible with MECL 3 logic.

  14. Overview of mesocale research Doppler lidar activities

    NASA Technical Reports Server (NTRS)

    Fitzjarrald, D. E.

    1984-01-01

    In evaluating the performance of the airborne Doppler lidar system, a large number of deficiencies or mistakes were identified in the original system and experiment plans. All of the known problems were addressed and corrected in the planning and engineering for the fall 1984/spring 1985 ADLS flight series. Thus, the most significant result of the data analysis was the input it has provided to the preparations for the new experiment. Attitude measurements are taken together with the streamlined operating procedures, color graphics real time displays of data, and better experiment design, the result is a second-generation system that is considerably better than the one used in 1981.

  15. In-suit Doppler technology assessment

    NASA Technical Reports Server (NTRS)

    Schulze, Arthur E.; Greene, Ernest R.; Nadeau, John J.

    1991-01-01

    The objective of this program was to perform a technology assessment survey of non-invasive air embolism detection utilizing Doppler ultrasound methodologies. The primary application of this technology will be a continuous monitor for astronauts while performing extravehicular activities (EVA's). The technology assessment was to include: (1) development of a full understanding of all relevant background research; and (2) a survey of the medical ultrasound marketplace for expertise, information, and technical capability relevant to this development. Upon completion of the assessment, LSR was to provide an overview of technological approaches and R&D/manufacturing organizations.

  16. Solar Doppler shifts - Sources of continuous spectra

    NASA Technical Reports Server (NTRS)

    Duvall, T. L., Jr.; Harvey, J. W.

    1986-01-01

    Oscillation observations can be used to study nonoscillatory solar phenomena that exhibit Doppler shifts. The paper discusses several effects of these phenomena and their associated temporal and spatial power spectra: (1) they limit the signal-to-noise ratio and sometimes detectability of oscillation modes; (2) there is the potential for better understanding and/or detection of solar phenomena; (3) large-scale convection may spatially modulate oscillation modes, leading to a continuous background spectrum; and (4) in regions of the spectrum where the resolution to separate modes is lacking one can determine upper limits for the integrated effects of modes.

  17. Applications of Doppler optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Xu, Zhiqiang

    A major development in biomedical imaging in the last decade has been optical coherence tomography (OCT). This technique enables microscale resolution, depth resolved imaging of the detailed morphology of transparent and nontransparent biological tissue in a noncontact and quasi-noninvasive way. In the first part of this dissertation, we will describe the development and the performance of our home-made OCT systems working with different wavelength regions based on free-space and optical fiber Michelson interferometers. The second part will focus on Doppler OCT (DOCT), an important extension of OCT, which enables the simultaneous evaluation of the structural information and of the fluid flow distribution at a localized position beneath the sample surface. Much effort has been spent during the past few years in our laboratory aimed at providing more accurate velocity measurements with an extended dynamic range. We also applied our technique in different research areas such as microfluidics and hemodynamics. Investigations on the optical properties of the biological tissues (such as absorption and scattering) corresponding to different center wavelengths, have been performed in our laboratory. We used a 10 femtosecond Ti:sapphire laser centered at about 810 nm associated with a free-space Michelson interferometer. The infrared sources were centered at about 1310 and 1560 nm with all-fiber interferometers. Comparative studies using three different sources for several in vitro biological tissues based on a graphical method illustrated how the optical properties affect the quality of the OCT images in terms of the penetration depth and backscattering intensity. We have shown the advantage of working with 810-nm emission wavelength for good backscattering amplitude and contrast, while sources emitting at 1570 nm give good penetration depth. The 1330-nm sources provide a good compromise between the two. Therefore, the choice of the source will ultimately determine the

  18. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    PubMed Central

    Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V

    2015-01-01

    Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: “Gestational trophoblastic disease AND Ultrasonography, Doppler.” Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. 1 Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. 2 There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. 3 Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. 4 Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. CONCLUSION: Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia. PMID:26735221

  19. Ambiguity resolution for satellite Doppler positioning systems

    NASA Technical Reports Server (NTRS)

    Argentiero, P.; Marini, J.

    1979-01-01

    The implementation of satellite-based Doppler positioning systems frequently requires the recovery of transmitter position from a single pass of Doppler data. The least-squares approach to the problem yields conjugate solutions on either side of the satellite subtrack. It is important to develop a procedure for choosing the proper solution which is correct in a high percentage of cases. A test for ambiguity resolution which is the most powerful in the sense that it maximizes the probability of a correct decision is derived. When systematic error sources are properly included in the least-squares reduction process to yield an optimal solution the test reduces to choosing the solution which provides the smaller valuation of the least-squares loss function. When systematic error sources are ignored in the least-squares reduction, the most powerful test is a quadratic form comparison with the weighting matrix of the quadratic form obtained by computing the pseudoinverse of a reduced-rank square matrix. A formula for computing the power of the most powerful test is provided. Numerical examples are included in which the power of the test is computed for situations that are relevant to the design of a satellite-aided search and rescue system.

  20. Doppler echocardiography in athletes from different sports

    PubMed Central

    Moro, Andre Santos; Okoshi, Marina Politi; Padovani, Carlos Roberto; Okoshi, Katashi

    2013-01-01

    Background Studies have shown cardiac changes induced by intense and regular physical activity. The purpose of this study was to evaluate cardiac structures and function in soccer players, cyclists and long-distance runners, and compare them with non-athlete controls. Material/Methods Cardiac structural, systolic, and diastolic function parameters in 53 athletes and 36 non-athlete controls were evaluated by Doppler echocardiography. Results Athletes presented higher left atrial volume, left ventricular (LV) thickness, and LV and right ventricular (RV) diastolic diameters (LVDD and RVDD, respectively) compared to non-athletes. Left atrium and LVDD were higher in cyclists than runners, and RVDD was higher in cyclists than soccer players. LV mass index was higher in athletes, and cyclists had higher values than runners and soccer players. LV systolic function did not differ significantly between groups. The only altered index of LV diastolic function was a higher E/A ratio in cyclists compared to controls. There was no difference in LV E/E’ ratio. RV systolic function evaluated by tissue Doppler imaging was higher in cyclists and soccer players than runners. There were no conclusive differences in RV diastolic function. Conclusions Soccer players, runners and cyclists had remodeling of left and right ventricular structures compared to controls. Cardiac remodeling was more intense in cyclists than runners and soccer players. PMID:23478754

  1. ALADIN doppler wind lidar: recent advances

    NASA Astrophysics Data System (ADS)

    Morancais, Didier; Fabre, Frédéric; Endemann, Martin; Culoma, Alain

    2007-10-01

    The Atmospheric Laser Doppler Instrument (ALADIN) is the payload of the ADM-Aeolus mission, which will provide direct measurements of global wind fields. It will determine the wind velocity component normal to the satellite velocity vector. The instrument is a direct detection Doppler Lidar operating in the UV, which will be the first of its kind in space. ALADIN comprises a high energy laser and a direct detection receiver operating on aerosol and molecular backscatter signals in parallel. The laser is all solid-state, based on Nd-YAG technology and high power laser diodes. The detector is a silicon CCD whose architecture allows on-chip accumulation of the returns, providing photon counting performance. The 1.5 m diameter telescope is lightweight, all made of silicon carbide. ALADIN is now in its final construction stage: the integration of the Flight Model is on-going. Most of the subsystems have been integrated; the payload performance and qualification test campaign will commence. This paper briefly describes the instrument design and provides insights on the development status and the results obtained so far. This regards in particular the receiver performance, the telescope development and the challenges of the laser. The Aeolus satellite is developed for the European Space Agency by EADS Astrium Satellites as prime contractor for the satellite and the instrument.

  2. An elementary approach to the gravitational Doppler shift

    NASA Astrophysics Data System (ADS)

    Wörner, C. H.; Rojas, Roberto

    2017-01-01

    In college physics courses, treatment of the Doppler effect is usually done far from the first introduction to kinematics. This paper aims to apply a graphical treatment to describe the gravitational redshift, by considering the Doppler effect in two accelerated reference frames and exercising the equivalence principle. This approach seems appropriate to discuss with beginner students and could serve to enrich the didactic processes.

  3. Tissue Doppler characterization of cardiac phenotype in mouse.

    PubMed

    Fayssoil, Abdallah

    2009-10-01

    Mice allow biologists to study various genes playing a role in cardiac function and pathophysiological situations. Echocardiography is a non-invasive tool for assessing cardiac phenotype. Because of load dependence of conventional parameters (left ventricular shortening fraction, left ventricular ejection fraction and mitral pulsed Doppler), we have to perform Doppler tissular velocity imaging and strain imaging for the characterization of cardiomyopathies mice models.

  4. Doppler weather radar with predictive wind shear detection capabilities

    NASA Technical Reports Server (NTRS)

    Kuntman, Daryal

    1991-01-01

    The status of Bendix research on Doppler weather radar with predictive wind shear detection capability is given in viewgraph form. Information is given on the RDR-4A, a fully coherent, solid state transmitter having Doppler turbulence capability. Frequency generation data, plans, modifications, system characteristics and certification requirements are covered.

  5. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended...

  6. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended...

  7. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended...

  8. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended...

  9. New Doppler echocardiographic applications for the study of diastolic function

    NASA Technical Reports Server (NTRS)

    Garcia, M. J.; Thomas, J. D.; Klein, A. L.

    1998-01-01

    Doppler echocardiography is one of the most useful clinical tools for the assessment of left ventricular (LV) diastolic function. Doppler indices of LV filling and pulmonary venous (PV) flow are used not only for diagnostic purposes but also for establishing prognosis and evaluating the effect of therapeutic interventions. The utility of these indices is limited, however, by the confounding effects of different physiologic variables such as LV relaxation, compliance and filling pressure. Since alterations in these variables result in changes in Doppler indices of opposite direction, it is often difficult to determine the status of a given variable when a specific Doppler filling pattern is observed. Recently, color M-mode and tissue Doppler have provided useful insights in the study of diastolic function. These new Doppler applications have been shown to provide an accurate estimate of LV relaxation and appear to be relatively insensitive to the effects of preload compensation. This review will focus on the complementary role of color M-mode and tissue Doppler echocardiography and traditional Doppler indices of LV filling and PV flow in the assessment of diastolic function.

  10. Investigations of atmospheric dynamics using a CW Doppler sounder array

    NASA Technical Reports Server (NTRS)

    Rao, G. L.

    1974-01-01

    A three-dimensional CW Doppler sounding system currently under operation at the NASA-Marshall Space Flight Center, Alabama is described. The properties of the neutral atmosphere are discussed along with the theory of Doppler sounding technique. Methods of data analyses used to investigate the dynamical phenomena at the ionospheric heights are presented and suggestions for future investigations provided.

  11. Ionospheric observations made by a time-interleaved Doppler ionosonde

    NASA Astrophysics Data System (ADS)

    Lynn, Kenneth J. W.

    2008-10-01

    Mid-latitude HF observations of ionospheric Doppler velocity as a function of frequency are reported here as observed over a quiet 24-h period by a KEL IPS71 ionosonde operating at a 5-min sampling rate. The unique time-interleaving technique used in this ionosonde provided a Doppler resolution of 0.04 Hz over a Doppler range of ±2.5 Hz at each sounding frequency via FFT processing and is described here for the first time. The time-interleaving technique can be applied to other types of ionosonde as well as to other applications. The measurements described were made at a middle latitude site (Salisbury, South Australia). Doppler variations (<30 min) were ever present throughout the day and showed short-period TID characteristics. The day-time Doppler shift was found to closely follow the rate-of-change of foF2 as predicted by a simple parabolic layer model. The descending cusp in short-period TIDs is shown to mark an abrupt change with increasing frequency from negative towards positive Doppler shift with the greatest change in Doppler shift being observed below the cusp. The “smilergram” is introduced as observed in both F2 and Sporadic E. The characteristic curve in Doppler versus group height at a single frequency is described and related to changes in reflection symmetry, velocity and depth of moving ionospheric inhomogeneities.

  12. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1550 Ultrasonic pulsed doppler...

  13. Micro-Doppler classification of riders and riderless horses

    NASA Astrophysics Data System (ADS)

    Tahmoush, David

    2014-05-01

    Micro-range Micro-Doppler can be used to isolate particular parts of the radar signature, and in this case we demonstrate the differences in the signature between a walking horse versus a walking horse with a rider. Using micro-range micro-Doppler, we can distinguish the radar returns from the rider as separate from the radar returns of the horse.

  14. Imaging doppler velocimeter with downward heterodyning in the optical domain

    DOEpatents

    Reu, Phillip L; Hansche, Bruce D

    2013-05-21

    In a Doppler velocimeter, the incoming Doppler-shifted beams are heterodyned to reduce their frequencies into the bandwidth of a digital camera. This permits the digital camera to produce at every sampling interval a complete two-dimensional array of pixel values. This sequence of pixel value arrays provides a velocity image of the target.

  15. Rotational Doppler effect in x-ray photoionization

    SciTech Connect

    Sun Yuping; Wang Chuankui; Gel'mukhanov, Faris

    2010-11-15

    The energy of the photoelectron experiences a red or blue Doppler shift when the molecule recedes from the detector or approaches him. This results in a broadening of the photoelectron line due to the translational thermal motion. However, the molecules also have rotational degrees of freedom and we show that the translational Doppler effect has its rotational counterpart. This rotational Doppler effect leads to an additional broadening of the spectral line of the same magnitude as the Doppler broadening caused by translational thermal motion. The rotational Doppler broadening as well as the rotational recoil broadening is sensitive to the molecular orbital from which the photoelectron is ejected. This broadening should be taken into account in analysis of x-ray photoemission spectra of super-high resolution and it can be directly observed using x-ray pump-probe spectroscopy.

  16. One way Doppler extractor. Volume 1: Vernier technique

    NASA Technical Reports Server (NTRS)

    Blasco, R. W.; Klein, S.; Nossen, E. J.; Starner, E. R.; Yanosov, J. A.

    1974-01-01

    A feasibility analysis, trade-offs, and implementation for a One Way Doppler Extraction system are discussed. A Doppler error analysis shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared and a Vernier technique is developed which obtains high Doppler resolution with low speed logic. Parameter trade-offs and sensitivities for the Vernier technique are analyzed, leading to a hardware design configuration. A detailed design, operation, and performance evaluation of the resulting breadboard model is presented which verifies the theoretical performance predictions. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of less than 0.02 Hertz for a one second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

  17. Spline function approximation for velocimeter Doppler frequency measurement

    NASA Technical Reports Server (NTRS)

    Savakis, Andreas E.; Stoughton, John W.; Kanetkar, Sharad V.

    1989-01-01

    A spline function approximation approach for measuring the Doppler spectral peak frequency in a laser Doppler velocimeter system is presented. The processor is designed for signal bursts with mean Doppler shift frequencies up to 100 MHz, input turbulence up to 20 percent, and photon counts as low as 300. The frequency-domain processor uses a bank of digital bandpass filters for the capture of the energy spectrum of each signal burst. The average values of the filter output energies, as a function of normalized frequency, are modeled as deterministic spline functions which are linearly weighted to evaluate the spectral peak location associated with the Doppler shift. The weighting coefficients are chosen to minimize the mean square error. Performance evaluation by simulation yields average errors in estimating mean Doppler frequencies within 0.5 percent for poor signal-to-noise conditions associated with a low photon count of 300 photons/burst.

  18. Doppler-cancelled response to VLF gravitational waves

    NASA Technical Reports Server (NTRS)

    Caporali, A.

    1981-01-01

    The interaction of long periodic gravitational waves with a three link microwave system known as the Doppler Cancelling System is discussed. This system, which was developed for a gravitational redshift experiment, uses one-way and two-way Doppler informatin to construct the beat signal of two reference oscillators moving with respect to each other. The geometric optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational wave space-time. The signature left on the Doppler-cancelled beat by burst and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler Cancelling System and that of a Doppler tracking system which employs two-way, round-trip radio waves. A three-fold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences.

  19. Hands-Free Transcranial Color Doppler Probe

    NASA Technical Reports Server (NTRS)

    Chin, Robert; Madala, Srihdar; Sattler, Graham

    2012-01-01

    Current transcranial color Doppler (TCD) transducer probes are bulky and difficult to move in tiny increments to search and optimize TCD signals. This invention provides miniature motions of a TCD transducer probe to optimize TCD signals. The mechanical probe uses spherical bearing in guiding and locating the tilting crystal face. The lateral motion of the crystal face as it tilts across the full range of motion was achieved by minimizing the distance between the pivot location and the crystal face. The smallest commonly available metal spherical bearing was used with an outer diameter of 12 mm, a 3-mm tall retaining ring, and 5-mm overall height. Small geared motors were used that would provide sufficient power in a very compact package. After confirming the validity of the basic positioning concept, optimization design loops were completed to yield the final design.

  20. Microscale Heat Conduction Models and Doppler Feedback

    SciTech Connect

    Hawari, Ayman I.; Ougouag, Abderrafi

    2015-01-22

    The objective of this project is to establish an approach for providing the fundamental input that is needed to estimate the magnitude and time-dependence of the Doppler feedback mechanism in Very High Temperature reactors. This mechanism is the foremost contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic (TRISO) coated particles. Therefore, its correct prediction is essential to the conduct of safety analyses for these reactors. Since the effect is directly dependent on the actual temperature reached by the fuel during transients, the underlying phenomena of heat deposition, heat transfer and temperature rise must be correctly predicted. To achieve the above objective, this project will explore an approach that accounts for lattice effects as well as local temperature variations and the correct definition of temperature and related local effects.

  1. Doppler interpretation of quasar red shifts.

    PubMed

    Zapolsky, H S

    1966-08-05

    The hypothesis that the quasistellar sources (quasars) are local objects moving with velocities close to the speed of light is examined. Provided there is no observational cutoff on apparent bolometric magnitude for the quasars, the transverse Doppler effect leads to the expectation of fewer blue shifts than red shifts for an isotropic distribution of velocities. Such a distribution also yields a function N(z), the number of objects with red shift less than z which is not inconsistent with the present data. On the basis of two extreme assumptions concerning the origin of such rapidly moving sources, we computed curves of red shift plotted against magnitude. In particular, the curve obtained on the assumption that the quasars originated from an explosion in or nearby our own galaxy is in as good agreement with the observations as the curve of cosmological red shift plotted against magnitude.

  2. Laser Doppler systems in atmospheric turbulence

    NASA Technical Reports Server (NTRS)

    Murty, S. S. R.

    1976-01-01

    The loss of heterodyne signal power for the Marshall Space Flight Center laser Doppler system due to the random changes in the atmospheric index of refraction is investigated. The current status in the physics of low energy laser propagation through turbulent atmosphere is presented. The analysis and approximate evaluation of the loss of the heterodyne signal power due to the atmospheric absorption, scattering, and turbulence are estimated for the conditions of the January 1973 flight tests. Theoretical and experimental signal to noise values are compared. Maximum and minimum values of the atmospheric attenuation over a two way path of 20 km range are calculated as a function of altitude using models of atmosphere, aerosol concentration, and turbulence.

  3. Doppler cooling and trapping on forbidden transitions.

    PubMed

    Binnewies, T; Wilpers, G; Sterr, U; Riehle, F; Helmcke, J; Mehlstäubler, T E; Rasel, E M; Ertmer, W

    2001-09-17

    Ultracold atoms at temperatures close to the recoil limit have been achieved by extending Doppler cooling to forbidden transitions. A cloud of (40)Ca atoms has been cooled and trapped to a temperature as low as 6 microK by operating a magnetooptical trap on the spin-forbidden intercombination transition. Quenching the long-lived excited state with an additional laser enhanced the scattering rate by a factor of 15, while a high selectivity in velocity was preserved. With this method, more than 10% of precooled atoms from a standard magnetooptical trap have been transferred to the ultracold trap. Monte Carlo simulations of the cooling process are in good agreement with the experiments.

  4. Laser Doppler vibrometry: new ENT applications

    NASA Astrophysics Data System (ADS)

    Stasche, Norbert; Baermann, M.; Kempe, C.; Hoermann, Karl; Foth, Hans-Jochen

    1996-12-01

    Common audiometry often does not really allow a reliable and objective differential diagnosis of hearing disorders such as otosclerosis, adhesive otitis, ossicular interruption or tinnitus, even though several methods might be used complementarily. In recent years, some experimental studies on middle ear mechanics established laser Doppler vibrometry (LDV) as a useful method allowing objective measurement of human tympanic membrane displacement. The present study on LDV investigated the clinical use of this new method under physiological conditions. LDV proved to be a fast, reproducible, non-invasive and very sensitive instrument to characterize ear-drum vibrations in various middle ear dysfunctions, except in tinnitus patients. For future applications, improved optical characteristics of the vibrometer might result in a better differential diagnosis of subjective and objective tinnitus, otoacoustic emissions or Morbus Meniere.

  5. Phase Doppler anemometry as an ejecta diagnostic

    NASA Astrophysics Data System (ADS)

    Bell, D. J.; Chapman, D. J.

    2017-01-01

    When a shock wave is incident on a free surface, micron sized pieces of the material can be ejected from that surface. Phase Doppler Anemometry (PDA) is being developed to simultaneously measure the sizes and velocities of the individual shock induced ejecta particles; providing an important insight into ejecta phenomena. The results from experiments performed on the 13 mm bore light gas gun at the Institute of Shock Physics, Imperial College London are presented. Specially grooved tin targets were shocked at pressures of up to 14 GPa, below the melt on release pressure, to generate ejecta particles. These experiments are the first time that PDA has been successfully fielded on dynamic ejecta experiments. The results and current state of the art of the technique are discussed along with the future improvements required to optimise performance and increase usability.

  6. The generalized Doppler effect for surface waves

    NASA Astrophysics Data System (ADS)

    Michel, G.

    2016-11-01

    We investigate energy exchanges through scales occurring when a surface wave reflects on a harmonically oscillating wall. We first experimentally evidence the creation of Doppler-shifted waves and measure their height as a function of the oscillation amplitude. Then, we theoretically compute the amplitudes of these new waves in the gravity regime. Both results show that even without bulk non-linearities, oscillating paddles in a fluid container lead to a complex wave energy spectrum competing with the one predicted by wave turbulence. To exemplify this point, we characterize a simple one-dimensional model consisting of a linear wave equation in an oscillating cavity with distinct injection and dissipation mechanisms. It displays features usually associated with non-linearities, as self-similarity in a spectral domain (the so-called inertial range), appearance of energy at larger and/or lower scales than the forcing one and creation of shock waves.

  7. NEXRAD - An advanced Doppler weather radar system

    NASA Astrophysics Data System (ADS)

    Durham, A. F.

    The WSR-57 system, which was first placed into operation in 1957, forms the backbone of the current radar observation network of the National Weather Service. However, in connection with its age, it has become increasingly difficult and expensive to maintain this system. The present investigation is concerned with the replacement of the WSR-57 by a new system which incorporates important advances made in radar technology since the 1950s. The new system considered, called the Next Generation Weather Radar (NEXRAD) makes use of highly automated Doppler techniques to measure the radial velocity of air movement within the internal structure of a storm system. Attention is given to background regarding the NEXRAD system development, the four phases of the NEXRAD program, NEXRAD system capabilities, operational (display) products, and questions of siting.

  8. Widefield laser doppler velocimeter: development and theory.

    SciTech Connect

    Hansche, Bruce David; Reu, Phillip L.; Massad, Jordan Elias

    2007-03-01

    The widefield laser Doppler velocimeter is a new measurement technique that significantly expands the functionality of a traditional scanning system. This new technique allows full-field velocity measurements without scanning, a drawback of traditional measurement techniques. This is particularly important for tests in which the sample is destroyed or the motion of the sample is non-repetitive. The goal of creating ''velocity movies'' was accomplished during the research, and this report describes the current functionality and operation of the system. The mathematical underpinnings and system setup are thoroughly described. Two prototype experiments are then presented to show the practical use of the current system. Details of the corresponding hardware used to collect the data and the associated software to analyze the data are presented.

  9. Spacecraft Doppler tracking with a VLBI antenna

    NASA Technical Reports Server (NTRS)

    Comoretto, G.; Iess, L.; Bertotti, B.; Brenkle, J. P.; Horton, T.

    1990-01-01

    Preliminary results are reported from Doppler-shift measurements to the Voyager-2 spacecraft at a distance of 26 AU, obtained using the 32-m VLBI antenna at Medicina (Italy) during July and August 1988. The apparatus comprises the el-az antenna, an S-X-band receiver, a hydrogen maser to generate the reference signal, a Mark III VLBI terminal, and a digital tone extractor capable of isolating a tone of known frequency from a noisy signal and giving its phase and amplitude. A signal transmitted in S-band from the NASA Deep Space Network (DSN) station in Australia and retransmitted coherently in X-band by Voyager, was received 7 h 6 min later at Medicina and at the DSN station in Madrid. Sample data are presented graphically and shown to be of generally high quality; further in-depth analysis is under way.

  10. Cyclotron maser using the anomalous Doppler effect

    NASA Astrophysics Data System (ADS)

    Didenko, A. N.; Borisov, A. R.; Fomenko, G. P.; Shlapakovskii, A. S.; Shtein, Iu. G.

    1983-11-01

    The operation of an anomalous-Doppler-effect cyclotron-resonance maser using a waveguide partially filled with dielectric as the slow-wave system is reported. The device investigated is similar to that of Didenko et al. (1983) and comprises a 300-mm-long 50-mm-o.d. 30-mm-i.d. waveguide with fabric-laminate dielectric, located 150 mm from the cathode in a 500-mm-long region of uniform 0-20-kG magnetic field, and a coaxial magnetic-insulation gun producing a 13-mm-i.d. 25-mm-o.d. hollow electron beam. Radiation at 12 + or - 1 mm wavelength and optimum power 20 MW is observed using hot-carrier detectors, with a clear peak in the power-versus-magnetic-field curve at about 6.4 kG.

  11. DC coupled Doppler radar physiological monitor.

    PubMed

    Zhao, Xi; Song, Chenyan; Lubecke, Victor; Boric-Lubecke, Olga

    2011-01-01

    One of the challenges in Doppler radar systems for physiological monitoring is a large DC offset in baseband outputs. Typically, AC coupling is used to eliminate this DC offset. Since the physiological signals of interest include frequency content near DC, it is not desirable to simply use AC coupling on the radar outputs. While AC coupling effectively removes DC offset, it also introduces a large time delay and distortion. This paper presents the first DC coupled IQ demodulator printed circuit board (PCB) design and measurements. The DC coupling is achieved by using a mixer with high LO to RF port isolation, resulting in a very low radar DC offset on the order of mV. The DC coupled signals from the PCB radar system were successfully detected with significant LNA gain without saturation. Compared to the AC coupled results, the DC coupled results show great advantages of less signal distortion and more accurate rate estimation.

  12. Processing of the laser Doppler velocimeter signals

    NASA Technical Reports Server (NTRS)

    Meyers, J. F.; Feller, W. V.

    1973-01-01

    The laser Doppler velocimeter (LDV) is a probeless technique that provides a remote measurement of mean and fluctuating velocities. The measurement is actually obtained from small particles embedded in the flow which scatter light from an illuminating laser beam interference pattern. A portion of this scattered light is collected by a photomultiplier which yields an electronic signal whose frequency is directly proportional to the velocity of the small particles. The purpose of this paper is to describe and critically compare three techniques most used to process this electronic signal. These techniques are: (1) spectrum analyzer - a frequency scanning filter (frequency domain instrument), (2) wide-band frequency tracker - a frequency lock loop (frequency domain instrument), and (3) high-speed frequency counter - an interval timer (time domain instrument). The study determines the ability of each technique to process the LDV signal and yield velocity data to be used in determining the flow characteristics.

  13. [Use of laser Doppler flowmetry in dentistry].

    PubMed

    Roeykens, H; Nammour, S; De Moor, R

    2009-01-01

    An early determination of pulpal vitality is crucial with respect to a correct differential diagnosis of revascularisation or necrosis and its treatment. The use of sensibility tests (cold, heat, electrical pulp test) in combination with X-ray are commonly promoted. However these tests are arbitrary, based on sensations and therefore not always reliable. In such situation the registration of 'real' pulpal blood flow and hence pulp vitality will be more than an added value. The most studied and well documented method is laser Doppler flowmetry (LDF) as it is non invasive, direct and objective. In this article we describe blood flow, LDF and its characteristics, advantages and disadvantages of this method and the newest developments regarding LDF. Despite a low implementation of LDF in Belgium, this technique proved to belong indisputable to the basic assets of a dental clinic. A number of cases are described to demonstrate the efficacy and added value of LDF in assessing tooth vitality.

  14. Wind Field Measurements With Airborne Doppler Lidar

    NASA Technical Reports Server (NTRS)

    Menzies, Robert T.

    1999-01-01

    In collaboration with lidar atmospheric remote sensing groups at NASA Marshall Space Flight Center and National Oceanic and Atmospheric Administration (NOAA) Environmental Technology Laboratory, we have developed and flown the Multi-center Airborne Coherent Atmospheric Wind Sensor (MACAWS) lidar on the NASA DC-8 research aircraft. The scientific motivations for this effort are: to obtain measurements of subgrid scale (i.e. 2-200 km) processes and features which may be used to improve parameterizations in global/regional-scale models; to improve understanding and predictive capabilities on the mesoscale; and to assess the performance of Earth-orbiting Doppler lidar for global tropospheric wind measurements. MACAWS is a scanning Doppler lidar using a pulsed transmitter and coherent detection; the use of the scanner allows 3-D wind fields to be produced from the data. The instrument can also be radiometrically calibrated and used to study aerosol, cloud, and surface scattering characteristics at the lidar wavelength in the thermal infrared. MACAWS was used to study surface winds off the California coast near Point Arena, with an example depicted in the figure below. The northerly flow here is due to the Pacific subtropical high. The coastal topography interacts with the northerly flow in the marine inversion layer, and when the flow passes a cape or point that juts into the winds, structures called "hydraulic expansion fans" are observed. These are marked by strong variation along the vertical and cross-shore directions. The plots below show three horizontal slices at different heights above sea level (ASL). Bottom plots are enlargements of the area marked by dotted boxes above. The terrain contours are in 200-m increments, with the white spots being above 600-m elevation. Additional information is contained in the original.

  15. Laser Doppler flowmetry in endodontics: a review.

    PubMed

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  16. Doppler sensitivity and its effect on transatlantic TWSTFT links

    NASA Astrophysics Data System (ADS)

    Zhang, Shengkang; Parker, Thomas; Zhang, Victor

    2017-02-01

    Some investigations have concluded that the diurnal pattern in the time comparison results of present two way satellite time and frequency transfer (TWSTFT) links may come mainly from Doppler dependent errors in the time of arrival (TOA) measurements made by the receivers of the TWSTFT modems. In this paper, several experiments were carried out to test if there is a Doppler dependent error in the ‘delay’ measurements of the receivers currently used. By simulating quantitative Doppler effects in the time transfer signal both on the carrier and the code, a type of Doppler sensitivity on the code was observed in the receivers, which has about  -0.49 ns offset in ‘delay’ measurement for a 1  ×  10-9 fractional Doppler shift. This sensitivity is basically the same for modems with different serial numbers from the same manufacture. We calculated this Doppler caused diurnal pattern in the time comparison results of the transatlantic TWSTFT link between NIST and PTB and found that it is very small and negligible, because the Doppler dependent error is almost identical in the NIST and PTB measurements and therefore it is nearly canceled in the TWSTFT difference. Commercial products are identified for technical completeness only, and no endorsement by NIST is implied.

  17. Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning.

    PubMed

    Lorintiu, Oana; Liebgott, Herve; Friboulet, Denis

    2016-04-01

    In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal allowed reducing the number of Doppler emissions and yielded better results than traditional interpolation and at least equivalent or even better depending on the configuration than the study estimating the signal from sparse data sets given in Jensen, 2006. We propose here to improve over this study by using a novel framework for randomly interleaving Doppler and US emissions. The proposed method reconstructs the Doppler signal segment by segment using a block sparse Bayesian learning (BSBL) algorithm based CS reconstruction. The interest of using such framework in the context of duplex Doppler is linked to the unique ability of BSBL to exploit block-correlated signals and to recover non-sparse signals. The performance of the technique is evaluated from simulated data as well as experimental in vivo data and compared to the recent results in Richy , 2013.

  18. Limits on Planetary Companions from Doppler Surveys of Nearby Stars

    NASA Astrophysics Data System (ADS)

    Howard, Andrew W.; Fulton, Benjamin J.

    2016-11-01

    Most of our knowledge of planets orbiting nearby stars comes from Doppler surveys. For spaced-based, high-contrast imaging missions, nearby stars with Doppler-discovered planets are attractive targets. The known orbits tell imaging missions where and when to observe, and the dynamically determined masses provide important constraints for the interpretation of planetary spectra. Quantifying the set of planet masses and orbits that could have been detected will enable more efficient planet discovery and characterization. We analyzed Doppler measurements from Lick and Keck Observatories by the California Planet Survey. We focused on stars that are likely targets for three space-based planet imaging mission concepts studied by NASA—WFIRST-AFTA, Exo-C, and Exo-S. The Doppler targets are primarily F8 and later main sequence stars, with observations spanning 1987-2014. We identified 76 stars with Doppler measurements from the prospective mission target lists. We developed an automated planet search and a methodology to estimate the pipeline completeness using injection and recovery tests. We applied this machinery to the Doppler data and computed planet detection limits for each star as a function of planet minimum mass and semimajor axis. For typical stars in the survey, we are sensitive to approximately Saturn-mass planets inside of 1 au, Jupiter-mass planets inside of ˜3 au, and our sensitivity declines out to ˜10 au. For the best Doppler targets, we are sensitive to Neptune-mass planets in 3 au orbits. Using an idealized model of Doppler survey completeness, we forecast the precision of future surveys of non-ideal Doppler targets that are likely targets of imaging missions. Based on observations obtained at the W. M. Keck Observatory, which is operated jointly by the University of California and the California Institute of Technology. Keck time has been granted by NASA, the University of California, and the University of Hawaii.

  19. Pulsed Doppler echocardiographic analysis of mitral regurgitation after myocardial infarction.

    PubMed

    Loperfido, F; Biasucci, L M; Pennestri, F; Laurenzi, F; Gimigliano, F; Vigna, C; Rossi, E; Favuzzi, A; Santarelli, P; Manzoli, U

    1986-10-01

    In 72 patients with previous myocardial infarction (MI), mitral regurgitation (MR) was assessed by pulsed-wave Doppler echocardiography and compared with physical and 2-dimensional echocardiographic findings. MR was found by Doppler in 29 of 42 patients (62%) with anterior MI, 11 of 30 (37%) with inferior MI (p less than 0.01) and in none of 20 normal control subjects. MR was more frequent in patients who underwent Doppler study 3 months after MI than in those who underwent Doppler at discharge (anterior MI = 83% vs 50%, p less than 0.01; inferior MI = 47% vs 27%, p = not significant). Of 15 patients who underwent Doppler studies both times, 3 (all with anterior MI) had MR only on the second study. Of the patients with Doppler MR, 12 of 27 (44%) with a left ventricular (LV) ejection fraction (EF) greater than 30% and 1 of 13 (8%) with an EF of 30% or less (p less than 0.01) had an MR systolic murmur. Mitral prolapse or eversion and papillary muscle fibrosis were infrequent in MI patients, whether or not Doppler MR was present. The degree of Doppler MR correlated with EF (r = -0.61), LV systolic volume (r = 0.47), and systolic and diastolic mitral anulus circumference (r = 0.52 and 0.51, respectively). Doppler MR was present in 24 of 28 patients (86%) with an EF of 40% or less and in 16 of 44 (36%) with EF more than 40% (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Modular high accuracy tracker for dual channel laser Doppler velocimeter

    NASA Technical Reports Server (NTRS)

    Fridman, J. D.; Young, R. M.; Seavey, R. E.; Orloff, K. L.

    1976-01-01

    In the study described, a scanning dual-channel cross-beam laser Doppler velocimeter (developed for measuring simultaneously the two orthogonal components of flow velocity and turbulence intensity) was used to measure the instantaneous velocity characteristics of a model helicopter rotor and in a vortex wake survey experiment on a Boeing 747 aircraft model. Particular attention is given to a special purpose dual-loop frequency tracker developed to track and demodulate 10 microsecond wide pulse burst Doppler signals with a study cycle of 25% (or narrower signals at a higher duty cycle) generated by the laser Doppler velocimeter.

  1. Mitigating Doppler shift effect in HF multitone data modem

    NASA Astrophysics Data System (ADS)

    Sonlu, Yasar

    1989-09-01

    Digital communications over High Frequency (HF) radio channels are getting important in recent years. Current HF requirements are for data transmission at rates 2.4 kbps or more to accommodate computer data links and digital secure voice. HF modems which were produced to meet these speeds are, serial modems and parallel modems. On the other hand, the HF sky-wave communication medium, the ionosphere, has some propagation problems such as multipath and Doppler shift. The effect of Doppler shift in a parallel modem which employs Differential Quadrature Phase Shift Keying (DQPSK) modulation is considered and a correction method to mitigate the Doppler Shift effect is introduced.

  2. Ultrasonic Doppler measurement of renal artery blood flow

    NASA Technical Reports Server (NTRS)

    Freund, W. R.; Beaver, W. L.; Meindl, J. D.

    1976-01-01

    Studies were made of (1) blood flow redistribution during lower body negative pressure (LBNP), (2) the profile of blood flow across the mitral annulus of the heart (both perpendicular and parallel to the commissures), (3) testing and evaluation of a number of pulsed Doppler systems, (4) acute calibration of perivascular Doppler transducers, (5) redesign of the mitral flow transducers to improve reliability and ease of construction, and (6) a frequency offset generator designed for use in distinguishing forward and reverse components of blood flow by producing frequencies above and below the offset frequency. Finally methodology was developed and initial results were obtained from a computer analysis of time-varying Doppler spectra.

  3. Laser Doppler anemometer signal processing for blood flow velocity measurements

    SciTech Connect

    Borozdova, M A; Fedosov, I V; Tuchin, V V

    2015-03-31

    A new method for analysing the signal in a laser Doppler anemometer based on the differential scheme is proposed, which provides the flow velocity measurement in strongly scattering liquids, particularly, blood. A laser Doppler anemometer intended for measuring the absolute blood flow velocity in animal and human near-surface arterioles and venules is developed. The laser Doppler anemometer signal structure is experimentally studied for measuring the flow velocity in optically inhomogeneous media, such as blood and suspensions of scattering particles. The results of measuring the whole and diluted blood flow velocity in channels with a rectangular cross section are presented. (laser applications and other topics in quantum electronics)

  4. Interferometric millimeter wave and THz wave doppler radar

    DOEpatents

    Liao, Shaolin; Gopalsami, Nachappa; Bakhtiari, Sasan; Raptis, Apostolos C.; Elmer, Thomas

    2015-08-11

    A mixerless high frequency interferometric Doppler radar system and methods has been invented, numerically validated and experimentally tested. A continuous wave source, phase modulator (e.g., a continuously oscillating reference mirror) and intensity detector are utilized. The intensity detector measures the intensity of the combined reflected Doppler signal and the modulated reference beam. Rigorous mathematics formulas have been developed to extract bot amplitude and phase from the measured intensity signal. Software in Matlab has been developed and used to extract such amplitude and phase information from the experimental data. Both amplitude and phase are calculated and the Doppler frequency signature of the object is determined.

  5. An audit of a hospital-based Doppler ultrasound quality control protocol using a commercial string Doppler phantom.

    PubMed

    Cournane, S; Fagan, A J; Browne, J E

    2014-05-01

    Results from a four-year audit of a Doppler quality assurance (QA) program using a commercially available Doppler string phantom are presented. The suitability of the phantom was firstly determined and modifications were made to improve the reliability and quality of the measurements. QA of Doppler ultrasound equipment is very important as data obtained from these systems is used in patient management. It was found that if the braided-silk filament of the Doppler phantom was exchanged with an O-ring rubber filament and the velocity range below 50 cm/s was avoided for Doppler quality control (QC) measurements, then the maximum velocity accuracy (MVA) error and intrinsic spectral broadening (ISB) results obtained using this device had a repeatability of 18 ± 3.3% and 19 ± 3.5%, respectively. A consistent overestimation of the MVA of between 12% and 56% was found for each of the tested ultrasound systems. Of more concern was the variation of the overestimation within each respective transducer category: MVA errors of the linear, curvilinear and phased array probes were in the range 12.3-20.8%, 32.3-53.8% and 27-40.7%, respectively. There is a dearth of QA data for Doppler ultrasound; it would be beneficial if a multicentre longitudinal study was carried out using the same Doppler ultrasound test object to evaluate sensitivity to deterioration in performance measurements.

  6. The Next Generation Airborne Polarimetric Doppler Radar

    NASA Astrophysics Data System (ADS)

    Vivekanandan, J.; Lee, Wen-Chau; Loew, Eric; Salazar, Jorge; Chandrasekar, V.

    2013-04-01

    NCAR's Electra Doppler radar (ELDORA) with a dual-beam slotted waveguide array using dual-transmitter, dual-beam, rapid scan and step-chirped waveform significantly improved the spatial scale to 300m (Hildebrand et al. 1996). However, ELDORA X-band radar's penetration into precipitation is limited by attenuation and is not designed to collect polarimetric measurements to remotely estimate microphysics. ELDORA has been placed on dormancy because its airborne platform (P3 587) was retired in January 2013. The US research community has strongly voiced the need to continue measurement capability similar to the ELDORA. A critical weather research area is quantitative precipitation estimation/forecasting (QPE/QPF). In recent years, hurricane intensity change involving eye-eyewall interactions has drawn research attention (Montgomery et al., 2006; Bell and Montgomery, 2006). In the case of convective precipitation, two issues, namely, (1) when and where convection will be initiated, and (2) determining the organization and structure of ensuing convection, are key for QPF. Therefore collocated measurements of 3-D winds and precipitation microphysics are required for achieving significant skills in QPF and QPE. Multiple radars in dual-Doppler configuration with polarization capability estimate dynamical and microphysical characteristics of clouds and precipitation are mostly available over land. However, storms over complex terrain, the ocean and in forest regions are not observable by ground-based radars (Bluestein and Wakimoto, 2003). NCAR/EOL is investigating potential configurations for the next generation airborne radar that is capable of retrieving dynamic and microphysical characteristics of clouds and precipitation. ELDORA's slotted waveguide array radar is not compatible for dual-polarization measurements. Therefore, the new design has to address both dual-polarization capability and platform requirements to replace the ELDORA system. NCAR maintains a C-130

  7. Doing the Doppler. How to Drive This Concept Home.

    ERIC Educational Resources Information Center

    Koser, John F.

    1990-01-01

    An outdoor activity that demonstrates the Doppler effect is described. Class predictions are verified by actual involvement in collecting data. Presented is a method of analyzing data. Safety concerns are discussed. (KR)

  8. The Doppler Effect: A Consideration of Quasar Redshifts.

    ERIC Educational Resources Information Center

    Gordon, Kurtiss J.

    1980-01-01

    Provides information on the calculation of the redshift to blueshift ratio introduced by the transverse Doppler effect at relativistic speeds. Indicates that this shift should be mentioned in discussions of whether quasars are "local" rather than "cosmological" objects. (GS)

  9. Doppler electron velocimetry : notes on creating a practical tool.

    SciTech Connect

    Reu, Phillip L.; Milster, Tom

    2008-11-01

    The Doppler electron velocimeter (DEV) has been shown to be theoretically possible. This report attempts to answer the next logical question: Is it a practical instrument? The answer hinges upon whether enough electrons are available to create a time-varying Doppler current to be measured by a detector with enough sensitivity and bandwidth. The answer to both of these questions is a qualified yes. A target Doppler frequency of 1 MHz was set as a minimum rate of interest. At this target a theoretical beam current signal-to-noise ratio of 25-to-1 is shown for existing electron holography equipment. A detector is also demonstrated with a bandwidth of 1-MHz at a current of 10 pA. Additionally, a Linnik-type interferometer that would increase the available beam current is shown that would offer a more flexible arrangement for Doppler electron measurements over the traditional biprism.

  10. Extracting and analyzing micro-Doppler from ladar signatures

    NASA Astrophysics Data System (ADS)

    Tahmoush, Dave

    2015-05-01

    Ladar and other 3D imaging modalities have the capability of creating 3D micro-Doppler to analyze the micro-motions of human subjects. An additional capability to the recognition of micro-motion is the recognition of the moving part, such as the hand or arm. Combined with measured RCS values of the body, ladar imaging can be used to ground-truth the more sensitive radar micro-Doppler measurements and associate the moving part of the subject with the measured Doppler and RCS from the radar system. The 3D ladar signatures can also be used to classify activities and actions on their own, achieving an 86% accuracy using a micro-Doppler based classification strategy.

  11. Coherent Doppler Lidar for Precision Navigation of Spacecrafts

    NASA Technical Reports Server (NTRS)

    Amzajerdian, Farzin; Pierrottet, Diego; Petway, Larry; Hines, Glenn; Lockhard, George; Barnes, Bruce

    2011-01-01

    A fiber-based coherent Doppler lidar, utilizing an FMCW technique, has been developed and its capabilities demonstrated through two successful helicopter flight test campaigns. This Doppler lidar is expected to play a critical role in future planetary exploration missions because of its ability in providing the necessary data for soft landing on the planetary bodies and for landing missions requiring precision navigation to the designated location on the ground. Compared with radars, the Doppler lidar can provide significantly higher precision velocity and altitude data at a much higher rate without concerns for measurement ambiguity or target clutter. Future work calls for testing the Doppler lidar onboard a rocket-powered free-flyer platform operating in a closed-loop with the vehicle s guidance, navigation, and control (GN&C) unit.

  12. Ambiguity Of Doppler Centroid In Synthetic-Aperture Radar

    NASA Technical Reports Server (NTRS)

    Chang, Chi-Yung; Curlander, John C.

    1991-01-01

    Paper discusses performances of two algorithms for resolution of ambiguity in estimated Doppler centroid frequency of echoes in synthetic-aperture radar. One based on range-cross-correlation technique, other based on multiple-pulse-repetition-frequency technique.

  13. Exploratory Meeting on Airborne Doppler Lidar Wind Velocity Measurements

    NASA Technical Reports Server (NTRS)

    Fichtel, G. H. (Editor); Kaufman, J. W. (Editor); Vaughan, W. W. (Editor)

    1980-01-01

    The scientific interests and applications of the Airborne Doppler Lidar Wind Velocity Measurement System to severe storms and local weather are discussed. The main areas include convective phenomena, local circulation, atmospheric boundary layer, atmospheric dispersion, and industrial aerodynamics.

  14. Apparatus and method for noninvasive particle detection using doppler spectroscopy

    DOEpatents

    Sinha, Dipen N.

    2016-05-31

    An apparatus and method for noninvasively detecting the presence of solid particulate matter suspended in a fluid flowing through a pipe or an oil and gas wellbore are described. Fluid flowing through a conduit containing the particulate solids is exposed to a fixed frequency (>1 MHz) of ultrasonic vibrations from a transducer attached to the outside of the pipe. The returning Doppler frequency shifted signal derived from the scattering of sound from the moving solid particles is detected by an adjacent transducer. The transmitted signal and the Doppler signal are combined to provide sensitive particulate detection. The magnitude of the signal and the Doppler frequency shift are used to determine the particle size distribution and the velocity of the particles. Measurement of the phase shift between the applied frequency and the detected Doppler shifted may be used to determine the direction of motion of the particles.

  15. Laser Doppler technology applied to atmospheric environmental operating problems

    NASA Technical Reports Server (NTRS)

    Weaver, E. A.; Bilbro, J. W.; Dunkin, J. A.; Jeffreys, H. B.

    1976-01-01

    Carbon dioxide laser Doppler ground wind data were very favorably compared with data from standard anemometers. As a result of these measurements, two breadboard systems were developed for taking research data: a continuous wave velocimeter and a pulsed Doppler system. The scanning continuous wave laser Doppler velocimeter developed for detecting, tracking and measuring aircraft wake vortices was successfully tested at an airport where it located vortices to an accuracy of 3 meters at a range of 150 meters. The airborne pulsed laser Doppler system was developed to detect and measure clear air turbulence (CAT). This system was tested aboard an aircraft, but jet stream CAT was not encountered. However, low altitude turbulence in cumulus clouds near a mountain range was detected by the system and encountered by the aircraft at the predicted time.

  16. Quantitative Measurement of the Doppler Shift at an Ultrasonic Frequency

    ERIC Educational Resources Information Center

    Nerbun, R. C.; Leskovec, R. A.

    1976-01-01

    Discussed is a Doppler shift laboratory experiment for an introductory college physics course. Ultrasonic transducers and a digital phase detector circuit "black box" are used to overcome room noise and "standing waves" and to produce an observable frequency shift. (SL)

  17. Software For Clear-Air Doppler-Radar Display

    NASA Technical Reports Server (NTRS)

    Johnston, Bruce W.

    1990-01-01

    System of software developed to present plan-position-indicator scans of clear-air Doppler radar station on color graphical cathode-ray-tube display. Designed to incorporate latest accepted standards for equipment, computer programs, and meteorological data bases. Includes use of Ada programming language, of "Graphical-Kernel-System-like" graphics interface, and of Common Doppler Radar Exchange Format. Features include portability and maintainability. Use of Ada software packages produced number of software modules reused on other related projects.

  18. Investigation of Surface Preparations to Enhance Photon Doppler Velocimetry Measurements

    DTIC Science & Technology

    2015-08-01

    SUPPLEMENTARY NOTES 14. ABSTRACT The work described in this report compiles empirical measurements of the intensity of 1.55-μm light reflected from...for conducting Photon Doppler Velocimetry measurements, which necessitates a prediction of the intensity of Doppler shifted light that will be...reflected from a surface to optimize the measurement. It was found that the intensity of reflected light could be sufficiently explained using the law of

  19. Doppler Spectra of Bistatic Reverberation from the Sea Surface.

    DTIC Science & Technology

    1979-05-08

    Doppler spectrum of surface scattered acoustic waves was performed by Liebermann [1-2]. Acoustic waves in air were scattered from capillary waves generated...scattered angle. Liebermann concluded that out of a broad spectrum of surface wave frequen- cies the wavelength most effective in scattering the acoustic... Liebermann , the theoretical prediction of a 1030 Hz Doppler shift was not in good agreement with the measured. It was suggested that nonlinear sur- face

  20. Using doppler radar images to estimate aircraft navigational heading error

    SciTech Connect

    Doerry, Armin W; Jordan, Jay D; Kim, Theodore J

    2012-07-03

    A yaw angle error of a motion measurement system carried on an aircraft for navigation is estimated from Doppler radar images captured using the aircraft. At least two radar pulses aimed at respectively different physical locations in a targeted area are transmitted from a radar antenna carried on the aircraft. At least two Doppler radar images that respectively correspond to the at least two transmitted radar pulses are produced. These images are used to produce an estimate of the yaw angle error.

  1. Doppler-resolved kinetics of saturation recovery

    SciTech Connect

    Forthomme, Damien; Hause, Michael L.; Yu, Hua -Gen; Dagdigian, Paul J.; Sears, Trevor J.; Hall, Gregory E.

    2015-04-08

    Frequency modulated laser transient absorption has been used to monitor the ground state rotational energy transfer rates of CN radicals in a double-resonance, depletion recovery experiment. When a pulsed laser is used to burn a hole in the equilibrium ground state population of one rotational state without velocity selection, the population recovery rate is found to depend strongly on the Doppler detuning of a narrow-band probe laser. Similar effects should be apparent for any relaxation rate process that competes effectively with velocity randomization. Alternative methods of extracting thermal rate constants in the presence of these non-thermal conditions are evaluated. Total recovery rate constants, analogous to total removal rate constants in an experiment preparing a single initial rotational level, are in good agreement with quantum scattering calculations, but are slower than previously reported experiments and show qualitatively different rotational state dependence between Ar and He collision partners. As a result, quasi-classical trajectory studies confirm that the differing rotational state dependence is primarily a kinematic effect.

  2. Atmospheric aerosol and Doppler lidar studies

    NASA Technical Reports Server (NTRS)

    Rothermel, Jeff; Bowdle, D. A.; Srivastava, V.; Jarzembski, M.; Cutten, D.; Mccaul, E. W., Jr.

    1991-01-01

    Experimental and theoretical studies were performed of atmospheric aerosol backscatter and atmospheric dynamics with Doppler lidar as a primary tool. Activities include field and laboratory measurement and analysis efforts. The primary focus of activities related to understanding aerosol backscatter is the GLObal Backscatter Experiment (GLOBE) program. GLOBE is a multi-element effort designed toward developing a global aerosol model to describe tropospheric clean background backscatter conditions that Laser Atmospheric Wind Sounder (LAWS) is likely to encounter. Two survey missions were designed and flown in the NASA DC-8 in November 1989 and May to June 1990 over the remote Pacific Ocean, a region where backscatter values are low and where LAWS wind measurements could make a major contribution. The instrument complement consisted of pulsed and continuous-wave (CW) CO2 gas and solid state lidars measuring aerosol backscatter, optical particle counters measuring aerosol concentration, size distribution, and chemical composition, a filter/impactor system collecting aerosol samples for subsequent analysis, and integrating nephelometers measuring visible scattering coefficients. The GLOBE instrument package and survey missions were carefully planned to achieve complementary measurements under clean background backscatter conditions.

  3. Doppler effect induced spin relaxation boom

    NASA Astrophysics Data System (ADS)

    Zhao, Xinyu; Huang, Peihao; Hu, Xuedong

    2016-03-01

    We study an electron spin qubit confined in a moving quantum dot (QD), with our attention on both spin relaxation, and the product of spin relaxation, the emitted phonons. We find that Doppler effect leads to several interesting phenomena. In particular, spin relaxation rate peaks when the QD motion is in the transonic regime, which we term a spin relaxation boom in analogy to the classical sonic boom. This peak indicates that a moving spin qubit may have even lower relaxation rate than a static qubit, pointing at the possibility of coherence-preserving transport for a spin qubit. We also find that the emitted phonons become strongly directional and narrow in their frequency range as the qubit reaches the supersonic regime, similar to Cherenkov radiation. In other words, fast moving excited spin qubits can act as a source of non-classical phonons. Compared to classical Cherenkov radiation, we show that quantum dot confinement produces a small but important correction on the Cherenkov angle. Taking together, these results have important implications to both spin-based quantum information processing and coherent phonon dynamics in semiconductor nanostructures.

  4. Doppler effect induced spin relaxation boom.

    PubMed

    Zhao, Xinyu; Huang, Peihao; Hu, Xuedong

    2016-03-21

    We study an electron spin qubit confined in a moving quantum dot (QD), with our attention on both spin relaxation, and the product of spin relaxation, the emitted phonons. We find that Doppler effect leads to several interesting phenomena. In particular, spin relaxation rate peaks when the QD motion is in the transonic regime, which we term a spin relaxation boom in analogy to the classical sonic boom. This peak indicates that a moving spin qubit may have even lower relaxation rate than a static qubit, pointing at the possibility of coherence-preserving transport for a spin qubit. We also find that the emitted phonons become strongly directional and narrow in their frequency range as the qubit reaches the supersonic regime, similar to Cherenkov radiation. In other words, fast moving excited spin qubits can act as a source of non-classical phonons. Compared to classical Cherenkov radiation, we show that quantum dot confinement produces a small but important correction on the Cherenkov angle. Taking together, these results have important implications to both spin-based quantum information processing and coherent phonon dynamics in semiconductor nanostructures.

  5. Doppler effect induced spin relaxation boom

    PubMed Central

    Zhao, Xinyu; Huang, Peihao; Hu, Xuedong

    2016-01-01

    We study an electron spin qubit confined in a moving quantum dot (QD), with our attention on both spin relaxation, and the product of spin relaxation, the emitted phonons. We find that Doppler effect leads to several interesting phenomena. In particular, spin relaxation rate peaks when the QD motion is in the transonic regime, which we term a spin relaxation boom in analogy to the classical sonic boom. This peak indicates that a moving spin qubit may have even lower relaxation rate than a static qubit, pointing at the possibility of coherence-preserving transport for a spin qubit. We also find that the emitted phonons become strongly directional and narrow in their frequency range as the qubit reaches the supersonic regime, similar to Cherenkov radiation. In other words, fast moving excited spin qubits can act as a source of non-classical phonons. Compared to classical Cherenkov radiation, we show that quantum dot confinement produces a small but important correction on the Cherenkov angle. Taking together, these results have important implications to both spin-based quantum information processing and coherent phonon dynamics in semiconductor nanostructures. PMID:26996253

  6. Doppler Tomography of A0620-00

    NASA Astrophysics Data System (ADS)

    Neilsen, Joseph; Steeghs, D.; Vrtilek, S. D.

    2007-05-01

    We present the results of spectroscopic observations of the quiescent black hole binary A0620-00 with LDSS3 on the Clay telescope at Las Campanas Observatory. We measure absorption-line radial velocities of the secondary and find K2=434.6±0.5 km/s; this is the most precise absorption-line radial velocity measurement for the system to date. By fitting the rotational broadening of the secondary, we measure the mass ratio q=0.060±0.04 these results, combined with the orbital period, imply a minimum mass for the compact object of 3.09±0.04 M⊙. Although X-ray quiescence implies little accretion activity, we find that the disk contributes ≥50% of the light in B and V, and is subject to significant flickering. The variability of the disk makes ellipsoidal constraints on the inclination nearly impossible. Doppler maps in Hα and Hβ show strong disk emission and a bright spot displaced from the gas stream; lower S/N lines show significant bright spot emission, consistent with Marsh et al. (1994). With high S/N, we pursue modulation tomography of Hα and find that the bright spot is strongly modulated at the orbital period. This research was funded by NSF grant 16640156, the Harvard University Graduate School of Arts and Sciences, and a Smithsonian Astrophysical Observatory Clay Fellowship.

  7. Doppler radar detection of vortex hazard indicators

    NASA Technical Reports Server (NTRS)

    Nespor, Jerald D.; Hudson, B.; Stegall, R. L.; Freedman, Jerome E.

    1994-01-01

    Wake vortex experiments were conducted at White Sands Missile Range, NM using the AN/MPS-39 Multiple Object Tracking Radar (MOTR). The purpose of these experiments was twofold. The first objective was to verify that radar returns from wake vortex are observed for some time after the passage of an aircraft. The second objective was to verify that other vortex hazard indicators such as ambient wind speed and direction could also be detected. The present study addresses the Doppler characteristics of wake vortex and clear air returns based upon measurements employing MOTR, a very sensitive C-Band phased array radar. In this regard, the experiment was conducted so that the spectral characteristics could be determined on a dwell to-dwell basis. Results are presented from measurements of the backscattered power (equivalent structure constant), radial velocity and spectral width when the aircraft flies transverse and axial to the radar beam. The statistics of the backscattered power and spectral width for each case are given. In addition, the scan strategy, experimental test procedure and radar parameters are presented.

  8. Doppler lidar signal and turbulence study

    NASA Technical Reports Server (NTRS)

    Frost, W.; Huang, K. H.

    1983-01-01

    Wind fields were measured with the ground-based NASA/MSFC lidar are compared with the in situ NASA RB-57 aircraft measurements. The mean wind fields, the turbulence intensities, and the turbulence spectra determined from measurements by both systems are in very good agreement. Turbulence intensities and spectra were calculated from the fluctuations with time in the radial wind speed component. The second moment or Doppler frequency spectral width of the lidar measurements was also compared with turbulence intensities measured by the aircraft. These second moments could only be resolved at the very low altitudes (in three range bins). Turbulence intensities estimated from the spectral width data were an order of magnitude higher than those measured by the aircraft. An interesting boundary layer evolved during the progress of the experiment. The breakup of a stable boundary layer resulted in winds blowing in one direction above 600 m msl and in the opposite direction below that level. Both the aircraft and the lidar systems clearly identified this unusual boundary layer flow and showed the identical trends.

  9. Zeeman Doppler Maps: Always Unique, Never Spurious?

    NASA Astrophysics Data System (ADS)

    Stift, Martin J.; Leone, Francesco

    2017-01-01

    Numerical models of atomic diffusion in magnetic atmospheres of ApBp stars predict abundance structures that differ from the empirical maps derived with (Zeeman) Doppler mapping (ZDM). An in-depth analysis of this apparent disagreement investigates the detectability by means of ZDM of a variety of abundance structures, including (warped) rings predicted by theory, but also complex spot-like structures. Even when spectra of high signal-to-noise ratio are available, it can prove difficult or altogether impossible to correctly recover shapes, positions, and abundances of a mere handful of spots, notwithstanding the use of all four Stokes parameters and an exactly known field geometry; the recovery of (warped) rings can be equally challenging. Inversions of complex abundance maps that are based on just one or two spectral lines usually permit multiple solutions. It turns out that it can by no means be guaranteed that any of the regularization functions in general use for ZDM (maximum entropy or Tikhonov) will lead to a true abundance map instead of some spurious one. Attention is drawn to the need for a study that would elucidate the relation between the stratified, field-dependent abundance structures predicted by diffusion theory on the one hand, and empirical maps obtained by means of “canonical” ZDM, i.e., with mean atmospheres and unstratified abundances, on the other hand. Finally, we point out difficulties arising from the three-dimensional nature of the atomic diffusion process in magnetic ApBp star atmospheres.

  10. Recent applications of acoustic Doppler current profilers

    USGS Publications Warehouse

    Oberg, K.A.; Mueller, David S.

    1994-01-01

    A Broadband acoustic Doppler current profiler (BB-ADCP) is a new instrument being used by the U.S. Geological Survey (USGS) to measure stream discharge and velocities, and bathymetry. During the 1993 Mississippi River flood, more than 160 high-flow BB-ADCP measurements were made by the USGS at eight locations between Quincy and Cairo, Ill., from July 19 to August 20, 1993. A maximum discharge of 31,400 m3/s was measured at St. Louis, Mo., on August 2, 1993. A BB-ADCP also has been used to measure leakage through three control structures near Chicago, Ill. These measurements are unusual in that the average velocity for the measured section was as low as 0.03 m/s. BB-ADCP's are also used in support of studies of scour at bridges. During the recent Mississippi River flood, BB-ADCP's were used to measure water velocities and bathymetry upstream from, next to, and downstream from bridge piers at several bridges over the Mississippi River. Bathymetry data were collected by merging location data from Global Positioning System (GPS) receivers, laser tracking systems, and depths measured by the BB-ADCP. These techniques for collecting bathymetry data were used for documenting the channel formation downstream from the Miller City levee break and scour near two bridges on the Mississippi River.

  11. Doppler-resolved kinetics of saturation recovery

    DOE PAGES

    Forthomme, Damien; Hause, Michael L.; Yu, Hua -Gen; ...

    2015-04-08

    Frequency modulated laser transient absorption has been used to monitor the ground state rotational energy transfer rates of CN radicals in a double-resonance, depletion recovery experiment. When a pulsed laser is used to burn a hole in the equilibrium ground state population of one rotational state without velocity selection, the population recovery rate is found to depend strongly on the Doppler detuning of a narrow-band probe laser. Similar effects should be apparent for any relaxation rate process that competes effectively with velocity randomization. Alternative methods of extracting thermal rate constants in the presence of these non-thermal conditions are evaluated. Totalmore » recovery rate constants, analogous to total removal rate constants in an experiment preparing a single initial rotational level, are in good agreement with quantum scattering calculations, but are slower than previously reported experiments and show qualitatively different rotational state dependence between Ar and He collision partners. As a result, quasi-classical trajectory studies confirm that the differing rotational state dependence is primarily a kinematic effect.« less

  12. Muscle activity characterization by laser Doppler Myography

    NASA Astrophysics Data System (ADS)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Primo Tomasini, Enrico

    2013-09-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin.

  13. Radar/sonar signal design for bounded Doppler shifts

    NASA Astrophysics Data System (ADS)

    Altes, R. A.

    1982-07-01

    In many detection and estimation problems, Doppler frequency shifts are bounded. For clutter or multipath that is uniformly distributed in range and symmetrically distributed in Doppler shift relative to the signal, detectability of a point target or a communication signal is improved by minimizing the weighted volume of the magnitude-squared autoambiguity function. When clutter Doppler shifts are bounded, this volume is in a strip containing the range axis on the range-Doppler plane. For scattering function estimation, e.g., for weather radar, Doppler flow meters, and distributed target classifiers, it is again relevant to minimize ambiguity volume in a strip. Strip volume is minimized by using a pulse train, but such a signal has unacceptably large range sidelobe for most applications. Other waveforms that have relatively small sidelobe level within a strip on the range-Doppler plane, as well as small ambiguity volume in the strip, are obtained. The waveforms are composed of pulse pairs that are phase modulated with Golay complementary codes.

  14. Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking.

    PubMed

    Armstrong, J W

    2006-01-01

    This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (∼millihertz) gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity 2Δv/c = Δν/ν0, where Δν is the Doppler shift and ν0 is the radio link carrier frequency. A gravitational wave having strain amplitude h incident on the earth-spacecraft system causes perturbations of order h in the time series of Δν/ν0. Unlike other detectors, the ∼ 1-10 AU earth-spacecraft separation makes the detector large compared with millihertz-band gravitational wavelengths, and thus times-of-flight of signals and radio waves through the apparatus are important. A burst signal, for example, is time-resolved into a characteristic signature: three discrete events in the Doppler time series. I discuss here the principles of operation of this detector (emphasizing transfer functions of gravitational wave signals and the principal noises to the Doppler time series), some data analysis techniques, experiments to date, and illustrations of sensitivity and current detector performance. I conclude with a discussion of how gravitational wave sensitivity can be improved in the low-frequency band.

  15. Doppler Monitoring of the WASP-47 Multiplanet System

    NASA Astrophysics Data System (ADS)

    Dai, Fei; Winn, Joshua N.; Arriagada, Pamela; Butler, R. Paul; Crane, Jeffrey D.; Johnson, John Asher; Shectman, Stephen A.; Teske, Johanna K.; Thompson, Ian B.; Vanderburg, Andrew; Wittenmyer, Robert A.

    2015-11-01

    We present precise Doppler observations of WASP-47, a transiting planetary system featuring a hot Jupiter with both inner and outer planetary companions. This system has an unusual architecture and also provides a rare opportunity to measure planet masses in two different ways: the Doppler method, and the analysis of transit-timing variations (TTV). Based on the new Doppler data, obtained with the Planet Finder Spectrograph on the Magellan/Clay 6.5 m telescope, the mass of the hot Jupiter is 370+/- 29 {M}\\oplus . This is consistent with the previous Doppler determination as well as the TTV determination. For the inner planet WASP-47e, the Doppler data lead to a mass of 12.2+/- 3.7 {M}\\oplus , in agreement with the TTV-based upper limit of <22 M⊕ (95% confidence). For the outer planet WASP-47d, the Doppler mass constraint of 10.4+/- 8.4 {M}\\oplus is consistent with the TTV-based measurement of {15.2}-7.6+6.7 {M}\\oplus . This paper includes data gathered with the 6.5 m Magellan Telescopes located at Las Campanas Observatory, Chile.

  16. Analysis of airborne Doppler lidar, Doppler radar and tall tower measurements of atmospheric flows in quiescent and stormy weather

    NASA Technical Reports Server (NTRS)

    Bluestein, H. B.; Doviak, R. J.; Eilts, M. D.; Mccaul, E. W.; Rabin, R.; Sundara-Rajan, A.; Zrnic, D. S.

    1986-01-01

    The first experiment to combine airborne Doppler Lidar and ground-based dual Doppler Radar measurements of wind to detail the lower tropospheric flows in quiescent and stormy weather was conducted in central Oklahoma during four days in June-July 1981. Data from these unique remote sensing instruments, coupled with data from conventional in-situ facilities, i.e., 500-m meteorological tower, rawinsonde, and surface based sensors, were analyzed to enhance understanding of wind, waves and turbulence. The purposes of the study were to: (1) compare winds mapped by ground-based dual Doppler radars, airborne Doppler lidar, and anemometers on a tower; (2) compare measured atmospheric boundary layer flow with flows predicted by theoretical models; (3) investigate the kinematic structure of air mass boundaries that precede the development of severe storms; and (4) study the kinematic structure of thunderstorm phenomena (downdrafts, gust fronts, etc.) that produce wind shear and turbulence hazardous to aircraft operations. The report consists of three parts: Part 1, Intercomparison of Wind Data from Airborne Lidar, Ground-Based Radars and Instrumented 444 m Tower; Part 2, The Structure of the Convective Atmospheric Boundary Layer as Revealed by Lidar and Doppler Radars; and Part 3, Doppler Lidar Observations in Thunderstorm Environments.

  17. A prospective analysis of free flap monitoring techniques: physical examination, external Doppler, implantable Doppler, and tissue oximetry.

    PubMed

    Lohman, Robert F; Langevin, Claude-Jean; Bozkurt, Mehmet; Kundu, Neilendu; Djohan, Risal

    2013-01-01

    No universally accepted method of flap monitoring exists, and several techniques are in use. Repeated physical examination is most popular and is often supplemented with a handheld, external Doppler, and/or implantable Doppler probes; near-infrared spectroscopy is less commonly used. We investigated the nursing and resident house staff's experience and confidence with physical exam for flap monitoring. Also, a consecutive series of 38 patients with free flaps were monitored using physical examination, external Doppler, implantable arterial and venous Doppler probes, and near-infrared spectroscopy. Five patients developed signs of microvascular complications within 3 days of surgery; all were explored and salvaged. Neither the residents nor the nursing staff were universally trained or experienced in flap monitoring by physical exam. In all patients, changes in the appearance of the flap suggestive of a microvascular complication lagged 30 to 60 minutes after the adjunctive monitoring methods indicated that a problem had occurred. Near-infrared spectroscopy was the first warning sign in four of the five patients. Two patients were explored before thrombosis of the anastomoses occurred. Near-infrared spectroscopy may identify early microvascular complications more reliably than physical examination, external Doppler, or implantable Doppler.

  18. Right Ventricular Tissue Doppler in Space Flight

    NASA Technical Reports Server (NTRS)

    Hamilton, Douglas R.; Barratt, Michael R.; Sargsyan, Ashot E.; Ebert, Douglas; Garcia, Kathleen M.; Martin, David S.; Dulchavsky, Scott A.; Duncan, J. Michael

    2009-01-01

    Tissue Doppler (TD) registers movement of a given sample of cardiac tissue throughout the cardiac cycle. TD spectra of the right ventricle (RV) were obtained from a long-duration ISS crewmember as a portion of an ongoing experiment ("Braslet" test objective). To our knowledge, this is the first report of RV TD conducted in space flight, and the data represent reproducibility and fidelity of this application in space and serve as the first "space normal" data set. Methods RV TD was performed by astronaut scientists remotely guided by an ultrasound expert from Mission Control Center, Houston, TX. In four of the subjects, RV TD was acquired from the free wall near the tricuspid annulus in two separate sessions 4 to 7 days apart. A fifth subject had only one session. All digital DICOM frames were exported for off-line analysis. Systolic (S ), early diastolic (E ) and late diastolic (A ) velocities were measured. RV Tei-index was calculated using diastolic and systolic time intervals as a combined measure of myocardial performance. Results and Discussion The mean values from the first 4 subjects (8 sessions) were used as the on-orbit reference data, and subject 5 was considered as a hypothetical patient for comparison (see Table). The greatest difference was in the early diastolic A (31 %) yet the standard deviation (a) for A amongst the reference subjects was 2.25 (mean = 16.02). Of interest is the Tei index, a simple and feasible indicator of overall ventricular function; it was similar amongst all the subjects. The late diastolic A seems to compensate for the variance in E . Normal Tei index for the RV is < 0.3, yet our data show all but one subject consistently above this level, notwithstanding their nominal responses to daily exercise in microgravity. These data remind us that the physiology of RV preload in altered gravity environments is still not completely understood.

  19. Doppler optical coherence tomography in cardiovascular applications

    NASA Astrophysics Data System (ADS)

    Bonesi, M.; Matcher, S.; Meglinski, I.

    2010-06-01

    The study of flow dynamics in complex geometry vessels is highly important in various biomedical applications where the knowledge of the mechanic interactions between the moving fluid and the housing media plays a key role for the determination of the parameters of interest, including the effect of blood flow on the possible rupture of atherosclerotic plaques. Doppler Optical Coherence Tomography (DOCT), as a functional extension of Optical Coherence Tomography (OCT), is an optic, non-contact, noninvasive technique able to achieve detailed analysis of the flow/vessel interactions. It allows simultaneous high resolution imaging (˜10 µm typical) of the morphology and composition of the vessel and determination of the flow velocity distribution along the measured cross-section. We applied DOCT system to image high-resolution one-dimensional and multi-dimensional velocity distribution profiles of Newtonian and non-Newtonian fluids flowing in vessels with complex geometry, including Y-shaped and T-shaped vessels, vessels with aneurism, bifurcated vessels with deployed stent and scaffolds. The phantoms were built to mimic typical shapes of human blood vessels, enabling preliminary analysis of the interaction between flow dynamics and the (complex) geometry of the vessels and also to map the related velocity profiles at several inlet volume flow rates. Feasibility studies for quantitative observation of the turbulence of flows arising within the complex geometry vessels are discussed. In addition, DOCT technique was also applied for monitoring cerebral mouse blood flow in vivo. Two-dimensional DOCT images of complex flow velocity profiles in blood vessel phantoms and in vivo sub-cranial mouse blood flow velocities distributions are presented.

  20. Doppler optical coherence tomography in cardiovascular physiology

    NASA Astrophysics Data System (ADS)

    Bonesi, M.; Meglinski, I.; Matcher, S.

    2008-09-01

    The study of flow dynamics in complex geometry vessels is highly important in many biomedical applications where the knowledge of the mechanic interactions between the moving fluid and the housing media plays a key role for the determination of the parameters of interest, including the effect of blood flow on the possible rupture of atherosclerotic plaques. Doppler Optical Coherence Tomography (DOCT), as a functional extension of Optical Coherence Tomography (OCT), is an optic, non-contact, non-invasive technique able to achieve detailed analysis of the flow/vessel interactions. It allows simultaneous high resolution imaging (10 μm typical) of the morphology and composition of the vessel and determination of the flow velocity distribution along the measured cross-section. We applied DOCT system to image high-resolution one-dimensional and multi-dimensional velocity distribution profiles of Newtonian and non-Newtonian fluids flowing in vessels with complex geometry, including Y-shaped and T-shaped vessels, vessels with aneurism, bifurcated vessels with deployed stent and scaffolds. The phantoms were built to mimic typical shapes of human blood vessels, enabling preliminary analysis of the interaction between flow dynamics and the (complex) geometry of the vessels and also to map the related velocity profiles at several inlet volume flow rates. Feasibility studies for quantitative observation of the turbulence of flows arising within the complex geometry vessels are discussed. In addition, DOCT technique was also applied for monitoring cerebral mouse blood flow in vivo. Two-dimensional DOCT images of complex flow velocity profiles in blood vessel phantoms and in vivo sub-cranial mouse blood flow velocities distributions are presented.

  1. Single Mode, Extreme Precision Doppler Spectrographs

    NASA Astrophysics Data System (ADS)

    Schwab, Christian; Leon-Saval, Sergio G.; Betters, Christopher H.; Bland-Hawthorn, Joss; Mahadevan, Suvrath

    2014-04-01

    The `holy grail' of exoplanet research today is the detection of an earth-like planet: a rocky planet in the habitable zone around a main-sequence star. Extremely precise Doppler spectroscopy is an indispensable tool to find and characterize earth-like planets; however, to find these planets around solar-type stars, we need nearly one order of magnitude better radial velocity (RV) precision than the best current spectrographs provide. Recent developments in astrophotonics (Bland-Hawthorn & Horton 2006, Bland-Hawthorn et al. 2010) and adaptive optics (AO) enable single mode fiber (SMF) fed, high resolution spectrographs, which can realize the next step in precision. SMF feeds have intrinsic advantages over multimode fiber or slit coupled spectrographs: The intensity distribution at the fiber exit is extremely stable, and as a result the line spread function of a well-designed spectrograph is fully decoupled from input coupling conditions, like guiding or seeing variations (Ihle et al. 2010). Modal noise, a limiting factor in current multimode fiber fed instruments (Baudrand & Walker 2001), can be eliminated by proper design, and the diffraction limited input to the spectrograph allows for very compact instrument designs, which provide excellent optomechanical stability. A SMF is the ideal interface for new, very precise wavelength calibrators, like laser frequency combs (Steinmetz et al. 2008, Osterman et al. 2012), or SMF based Fabry-Perot Etalons (Halverson et al. 2013). At near infrared wavelengths, these technologies are ready to be implemented in on-sky instruments, or already in use. We discuss a novel concept for such a spectrograph.

  2. The recondite intricacies of Zeeman Doppler mapping

    NASA Astrophysics Data System (ADS)

    Stift, M. J.; Leone, F.; Cowley, C. R.

    2012-02-01

    We present a detailed analysis of the reliability of abundance and magnetic maps of Ap stars obtained by Zeeman Doppler mapping (ZDM). It is shown how they can be adversely affected by the assumption of a mean stellar atmosphere instead of appropriate 'local' atmospheres corresponding to the actual abundances in a given region. The essence of the difficulties was already shown by Chandrasekhar's picket-fence model. The results obtained with a suite of Stokes codes written in the ADA programming language and based on modern line-blanketed atmospheres are described in detail. We demonstrate that the high metallicity values claimed to have been found in chemically inhomogeneous (horizontally and vertically) Ap star atmospheres would lead to local temperature structures, continuum and line intensities, and line shapes that differ significantly from those predicted by a mean stellar atmosphere. Unfortunately, past applications of ZDM have consistently overlooked the intricate aspects of metallicity with their all-pervading effects. The erroneous assumption of a mean atmosphere for a spotted star can lead to phase-dependent errors of uncomfortably large proportions at varying wavelengths both in the Stokes I and V profiles, making precise mapping of abundances and magnetic field vectors largely impossible. The relation between core and wings of the Hβ line changes, too, with possible repercussions on the determination of gravity and effective temperature. Finally, a ZDM analysis of the synthetic Stokes spectra of a spotted star reveals the disturbing differences between the respective abundance maps based on a mean atmosphere on the one hand, and on appropriate 'local' atmospheres on the other. We then discuss what this all means for published ZDM results. Our discussion makes it clear that realistic local atmospheres must be used, especially if credible small-scale structures are to be obtained. Recondite: dealing with very profound, difficult or abstruse subject

  3. Hands-Free Transcranial Color Doppler Probe

    NASA Technical Reports Server (NTRS)

    Chin, Robert; Madala, Srihdar; Sattler, Graham

    2012-01-01

    Current transcranial color Doppler (TCD) transducer probes are bulky and difficult to move in tiny increments to search and optimize TCD signals. This invention provides miniature motions of a TCD transducer probe to optimize TCD signals. The mechanical probe uses a spherical bearing in guiding and locating the tilting crystal face. The lateral motion of the crystal face as it tilts across the full range of motion was achieved by minimizing the distance between the pivot location and the crystal face. The smallest commonly available metal spherical bearing was used with an outer diameter of 12 mm, a 3-mm tall retaining ring, and 5-mm overall height. Small geared motors were used that would provide sufficient power in a very compact package. After confirming the validity of the basic positioning concept, optimization design loops were completed to yield the final design. A parallel motor configuration was used to minimize the amount of space wasted inside the probe case while minimizing the overall case dimensions. The distance from the front edge of the crystal to the edge of the case was also minimized to allow positioning of the probe very close to the ear on the temporal lobe. The mechanical probe is able to achieve a +/-20deg tip and tilt with smooth repeatable action in a very compact package. The enclosed probe is about 7 cm long, 4 cm wide, and 1.8 cm tall. The device is compact, hands-free, and can be adjusted via an innovative touchscreen. Positioning of the probe to the head is performed via conventional transducer gels and pillows. This device is amendable to having advanced software, which could intelligently focus and optimize the TCD signal.

  4. DOPPLER SIGNATURES OF THE ATMOSPHERIC CIRCULATION ON HOT JUPITERS

    SciTech Connect

    Showman, Adam P.; Lewis, Nikole K.; Fortney, Jonathan J.; Shabram, Megan

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation-and Doppler signature-of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blueshifted and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps these waves and inhibits jet formation. As a result, this second regime exhibits a circulation dominated by high-altitude, day-to-night airflow, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art circulation models including non-gray radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that cool planets like GJ 436b lie in the first regime, HD 189733b is transitional, while planets hotter than HD 209458b lie in the second regime. Moreover, we show how the amplitude of the Doppler shifts constrains the strength of frictional drag in the upper atmospheres of hot Jupiters. If due to winds, the {approx}2 km s{sup -1} blueshift inferred on HD 209458b may require drag time constants as short as 10{sup 4}-10{sup 6} s, possibly the result of Lorentz-force braking on this planet's hot dayside.

  5. Doppler broadening induced spectral shift effects on reactor safety

    SciTech Connect

    Alapour, A.

    1980-01-01

    It is commonly accepted that the resonance reaction rate of any material increases when the temperature is raised. However, in a nuclear reactor the increase in resonance reaction rates with temperature at relatively high energy shifts the neutron spectrum in such a way that a net decrease in the neutron flux results at lower energies. This finding suggested that the spectral shift could significantly affect the Doppler reactivity change, warranting further investigations. The objective was to study the physical characteristics of this new phenomenon and its effects on reactor safety. The desirability of studying this effect was strengthened by the presence of discrepancies between the calculated and measured integral experiments. An exact Doppler broadening kernel, based on the Maxwellian distribution of nuclear velocities, and an accurate integral transport method NDCRAB, capable of including resonance overlap of all materials present in the reactor cell, were used in this study. The ZPR-6 Assembly 7 benchmark, a typical LMFBR reactor, was used to quantify the Doppler reactivity change for an increase in fuel temperature and to analyze the natural UO/sub 3/ sample Doppler worth in this assembly. The quantification of the various components of the Doppler reactivity change shows that the fissile material, /sup 239/Pu, has a large negative Doppler effect and contributes a large fraction to the total negative effect. The calculated Doppler effect of the natural UO/sub 3/ sample in this assembly was in good agreement with the measured value. The calculated and measured values for an increase in sample temperature from 293-0K to 1100/sup 0/K wre -0.887 Ih/kgU and -0.868 Ih/kgU.

  6. Doppler Feature Based Classification of Wind Profiler Data

    NASA Astrophysics Data System (ADS)

    Sinha, Swati; Chandrasekhar Sarma, T. V.; Lourde. R, Mary

    2017-01-01

    Wind Profilers (WP) are coherent pulsed Doppler radars in UHF and VHF bands. They are used for vertical profiling of wind velocity and direction. This information is very useful for weather modeling, study of climatic patterns and weather prediction. Observations at different height and different wind velocities are possible by changing the operating parameters of WP. A set of Doppler power spectra is the standard form of WP data. Wind velocity, direction and wind velocity turbulence at different heights can be derived from it. Modern wind profilers operate for long duration and generate approximately 4 megabytes of data per hour. The radar data stream contains Doppler power spectra from different radar configurations with echoes from different atmospheric targets. In order to facilitate systematic study, this data needs to be segregated according the type of target. A reliable automated target classification technique is required to do this job. Classical techniques of radar target identification use pattern matching and minimization of mean squared error, Euclidean distance etc. These techniques are not effective for the classification of WP echoes, as these targets do not have well-defined signature in Doppler power spectra. This paper presents an effective target classification technique based on range-Doppler features.

  7. Renal power Doppler ultrasonographic evaluation of children with acute pyelonephritis.

    PubMed

    Shajari, Ahmad; Nafisi-Moghadam, Reza; Malek, Mahrooz; Smaili, Agha; Fallah, Mahmud; Pahlusi, Ali

    2011-01-01

    Urinary tract infections are common in children. The available gold standard method for diagnosis, Tc-99m dimercaptosuccinic acid scan is expensive and exposes patients to considerable amount of radiation. This study was performed to compare and assess the efficacy of Power Doppler Ultrasound versus Tc-99m DMSA scan for diagnosis of acute pyelonephritis. A quasi experimental study was conducted on 34 children with mean age of 2.8 ± 2.7 years who were hospitalized with their first episode of febrile urinary tract infection. All children were evaluated in the first 3 days of admission by Doppler Ultrasound and Tc-99m DMSA scan. Patients with congenital structural anomalies were excluded. Each kidney was divided into three zones. The comparison between efficacy of Doppler Ultrasound and DMSA scan was carried out based on number of patients and on classified renal units. Based on the number of patients enrolled; the sensitivity, specificity, positive and negative predictive values and accuracy of Doppler Ultrasound were 89%, 53%, 70%, 80% and 74%, respectively but based on the renal units, it was 66%, 81%, 46%, 91% and 79% , respectively. Although Doppler Ultrasound has the potential for identifying acute pyelonephritis in children, but it is still soon to replace DMSA scan.

  8. GEOS 3 STDN S band Doppler tracking investigation

    NASA Technical Reports Server (NTRS)

    Rosenbaum, B.

    1979-01-01

    GEOS 3S Doppler band and laser ranging data, acquired from August 1975 to March 1976 in the spacecraft altimeter calibration area, are examined. An evaluation of two-way and three-way Doppler data, for the positioning of Spaceflight Tracking and Data Network S band stations is presented, as well as the Goddard Space Flight Center laser system that is used to reference the exact position of the Doppler stations. The two-way and three-way Doppler tracking devices, situated at Rosman and Bermuda, have yielded data for the recovery of GEOS 3 arc height with an uncertainty of only 1 m. Attention is given to the effects of beacon signal frequency instability, controlled by a temperature sensitive auxiliary crystal oscillator on board the spacecraft, and to the one-way range rate tracking noise that was found to be within a range of 2 to 10 cm/s. 1- and 2-way passes and their different arc meters are graphed, showing the Doppler tracking interval. It was concluded that other accurate computations and recovery of station coordinates could be performed employing tracking data from S band stations.

  9. Long duration meteor echoes characterized by Doppler spectrum bifurcation

    NASA Astrophysics Data System (ADS)

    Bourdillon, A.; Haldoupis, C.; Hanuise, C.; Le Roux, Y.; Menard, J.

    2005-03-01

    We report on a new category of long lasting meteor echoes observed occasionally with HF and VHF radars. These meteoric returns, which have lifetimes from many seconds to a few minutes, are characterized by a distinct Doppler spectral signature showing a pronounced Doppler bifurcation which includes narrow bands of discrete Doppler velocities, often of opposite polarity. The large signal to noise ratios and the narrowness of the spectra imply that coherent or Bragg scattering is not of relevance here, therefore these echoes do not associate with the long living meteor-induced backscatter (MIB) from the lower E region. A reasonable interpretation needs to explain both the Doppler spectrum bifurcation and the long echo duration. As such, we propose the idea of a structured vertical wind shear in the lower E region which traps different fragments of a meteor trail plasma in the same way that sporadic E layers form. These trail parts inside the shear-related wind profile may act as relatively long-lasting meteoric reflectors moving with different Doppler velocities, also of opposite polarity.

  10. Temporal enhancement of two-dimensional color doppler echocardiography

    NASA Astrophysics Data System (ADS)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  11. Results of the international ionospheric Doppler sounder network

    NASA Astrophysics Data System (ADS)

    Lastovicka, Jan; Chum, Jaroslav

    2016-07-01

    This paper summarizes main recent results reached by the Czech-lead international network of ionospheric Doppler sounders. The network consists of Doppler sounders in the western half of Czechia (5 measuring paths, 3 frequencies with central receivers in Prague), northern Taiwan (3 transmitters, two separated receivers, 1 frequency), and three similar systems (3 measuring paths with 1 receiver and 1 frequency) in Tucuman (north-western Argentina), Hermanus (the southernmost South Africa) and Luisville (northern South Africa). Three main areas of research have been (1) statistical properties of gravity waves, (2) ionospheric effects of earthquakes, and (3) low latitude/equatorial phenomena. Some results: (1) the theoretically expected dominance of gravity wave propagation against wind has been confirmed; (2) impact of the Tohoku 2001 M9.0 earthquake was registered in the ionosphere over the Czech Republic as long-period infrasound on the distance of about 9000 km from epicenter; analysis of ionospheric infrasound excited by the Nepal 2015 M7.8 earthquake observed by the Czech and Taiwan Doppler sounders showed that the intensity of ionospheric signal is significantly height dependent and that the Doppler shift depends not only on the advection (up and down motion) of the reflecting layer but also on the compression/rarefaction of the electron gas; (3) spread F structures observed by Doppler sounders in Tucuman and Taiwan (both under the crest of equatorial ionization anomaly) provide results consistent with S4 scintillation data and with previous optical, GPS and satellite measurements.

  12. Response of a Doppler canceling system to plane gravitational waves

    NASA Technical Reports Server (NTRS)

    Caporali, A.

    1982-01-01

    This paper discusses the interaction of long periodic gravitational waves with a three-link microwave system known as the Doppler canceling system. This system, which was developed for a gravitational red-shift experiment, uses one-way and two-way Doppler information to construct the beat signal of two reference oscillators moving with respect to each other. The geometric-optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational-wave space-time. The signature left on the Doppler-cancelled beat by bursts and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler canceling system and that of a (NASA) Doppler tracking system which employs two-way, round-trip radio waves. A threefold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences.

  13. Selection functions in doppler planet searches

    NASA Astrophysics Data System (ADS)

    O'Toole, S. J.; Tinney, C. G.; Jones, H. R. A.; Butler, R. P.; Marcy, G. W.; Carter, B.; Bailey, J.

    2009-01-01

    We present a preliminary analysis of the sensitivity of Anglo-Australian Planet Search data to the orbital parameters of extrasolar planets. To do so, we have developed new tools for the automatic analysis of large-scale simulations of Doppler velocity planet search data. One of these tools is the two-dimensional Keplerian Lomb-Scargle (LS) periodogram that enables the straightforward detection of exoplanets with high eccentricities (something the standard LS periodogram routinely fails to do). We used this technique to redetermine the orbital parameters of HD20782b, with one of the highest known exoplanet eccentricities (e = 0.97 +/- 0.01). We also derive a set of detection criteria that do not depend on the distribution functions of fitted Keplerian orbital parameters (which we show are non-Gaussian with pronounced, extended wings). Using these tools, we examine the selection functions in orbital period, eccentricity and planet mass of Anglo-Australian Planet Search data for three planets with large-scale Monte Carlo like simulations. We find that the detectability of exoplanets declines at high eccentricities. However, we also find that exoplanet detectability is a strong function of epoch-to-epoch data quality, number of observations and period sampling. This strongly suggests that simple parametrizations of the detectability of exoplanets based on `whole-of-survey' metrics may not be accurate. We have derived empirical relationships between the uncertainty estimates for orbital parameters that are derived from least-squares Keplerian fits to our simulations and the true 99 per cent limits for the errors in those parameters, which are larger than equivalent Gaussian limits by the factors of 5-10. We quantify the rate at which false positives are made by our detection criteria, and find that they do not significantly affect our final conclusions. And finally, we find that there is a bias against measuring near-zero eccentricities, which becomes more significant

  14. Signal processing considerations for low signal to noise ratio laser Doppler and phase Doppler signals

    NASA Technical Reports Server (NTRS)

    Ibrahim, K. M.; Wertheimer, G. D.; Bachalo, William D.

    1991-01-01

    The relative performance of current methods used for estimating the phase and the frequency in LDV and phase Doppler applications in low signal to noise ratio conditions is analyzed. These methods include the Fourier analysis and the correlation techniques. Three methods that use the correlation function for frequency and phase estimations are evaluated in terms of accuracy and speed of processing. These methods include: (1) the frequency estimation using zero crossings counting of the auto-correlation function, (2) the Blackman-Tukey method, and (3) the AutoRegressive method (AR). The relative performance of these methods is evaluated and compared with the Fourier analysis method which provides the optimum performance in terms of the Maximum Likelihood (ML) criteria.

  15. Imaging nanoparticle flow using magneto-motive optical Doppler tomography.

    PubMed

    Kim, Jeehyun; Oh, Junghwan; Milner, Thomas E; Nelson, J Stuart

    2007-01-24

    We introduce a novel approach for imaging solutions of superparamagnetic iron oxide (SPIO) nanoparticles using magneto-motive optical Doppler tomography (MM-ODT). MM-ODT combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect nanoparticles flowing through a microfluidic channel. A solenoid with a cone-shaped ferrite core extensively increased the magnetic field strength (B(max) = 1 T, [Formula: see text]) at the tip of the core and also focused the magnetic field in microfluidic channels containing nanoparticle solutions. Nanoparticle contrast was demonstrated in a microfluidic channel filled with an SPIO solution by imaging the Doppler frequency shift which was observed independently of the nanoparticle flow rate and direction. Results suggest that MM-ODT may be applied to image Doppler shift of SPIO nanoparticles in microfluidic flows with high contrast.

  16. It's all in the past: Deconstructing the temporal Doppler effect.

    PubMed

    Aksentijevic, Aleksandar; Treider, John Melvin Gudnyson

    2016-10-01

    A recent study reported an asymmetry between subjective estimates of future and past distances with passive estimation and virtual movement. The temporal Doppler effect refers to the contraction of future distance judgments relative to past ones. We aimed to replicate the effect using real and imagined motion in both directions as well as different temporal perspectives. To avoid the problem of subjective anchoring, we compared real- and imagined-, ego- and time-moving conditions to a control group. Generally, Doppler-like distortion was only observed in conditions in which the distance between the participant and a frontal target increased. No effects of temporal perspective were observed. The "past-directed temporal Doppler effect" presents a challenge for the current theories of temporal cognition by demonstrating absence of psychological movement into the future. The effect could open new avenues in memory research and serve as a starting point in a systematic examination of how the humans construct future.

  17. Manipulating the spin-dependent splitting by geometric Doppler effect.

    PubMed

    Liu, Yachao; Ke, Yougang; Zhou, Junxiao; Luo, Hailu; Wen, Shuangchun

    2015-06-29

    We report the manipulation of spin-dependent splitting by geometric Doppler effect based on dielectric metasurfaces. The extrapolation of rotational Doppler effect from temporal to spatial coordinate gives the phase change when the local optical axes of dielectric metasurfaces are rotating in space. Therefore, the continuous variation of local optical axes in a certain direction will introduce a phase gradient in the same direction at the beam cross section. This is additive to the phase gradient appeared when breaking the rotational symmetry of linearly polarized cylindrical vector beams, which leads to the deflections of different spin components of light, i.e., photonic spin Hall effect. Hence, it is possible to manipulate the spin-dependent splitting by introducing the geometric Doppler effect. Theoretically and experimentally, we show that the magnitude and orientation of the spin-dependent splitting are both tunable when changing the spatial rotation rate of local optical axes and incident polarization.

  18. Rotational Doppler Effect: A Probe for Molecular Orbitals Anisotropy.

    PubMed

    Miao, Quan; Travnikova, Oksana; Gel'mukhanov, Faris; Kimberg, Victor; Sun, Yu-Ping; Thomas, T Darrah; Nicolas, Christophe; Patanen, Minna; Miron, Catalin

    2015-05-07

    The vibrationally resolved X-ray photoelectron spectra of X2Σg+(3σg−1) and B2Σu+(2σu−1) states of N2+ were recorded for different photon energies and orientations of the polarization vector. Clear dependencies of the spectral line widths on the X-ray polarization as well as on the symmetry of the final electronic states are observed. Contrary to the translational Doppler, the rotational Doppler broadening is sensitive to the photoelectron emission anisotropy. On the basis of theoretical modeling, we suggest that the different rotational Doppler broadenings observed for gerade and ungerade final states result from a Young's double-slit interference phenomenon.

  19. Theoretical analysis and experimental verification on optical rotational Doppler effect.

    PubMed

    Zhou, Hailong; Fu, Dongzhi; Dong, Jianji; Zhang, Pei; Zhang, Xinliang

    2016-05-02

    We present a theoretical model to sufficiently investigate the optical rotational Doppler effect based on modal expansion method. We find that the frequency shift content is only determined by the surface of spinning object and the reduced Doppler shift is linear to the difference of mode index between input and output orbital angular momentum (OAM) light, and linear to the rotating speed of spinning object as well. An experiment is carried out to verify the theoretical model. We explicitly suggest that the spatial spiral phase distribution of spinning object determines the frequency content. The theoretical model makes us better understand the physical processes of rotational Doppler effect, and thus has many related application fields, such as detection of rotating bodies, imaging of surface and measurement of OAM light.

  20. Modeling and processing of laser Doppler reactive hyperaemia signals

    NASA Astrophysics Data System (ADS)

    Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre

    2003-07-01

    Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.

  1. Doppler Cooling Trapped Ions with a UV Frequency Comb.

    PubMed

    Davila-Rodriguez, Josue; Ozawa, Akira; Hänsch, Theodor W; Udem, Thomas

    2016-01-29

    We demonstrate Doppler cooling of trapped magnesium ions using a frequency comb at 280 nm obtained from a frequency tripled Ti:sapphire laser. A comb line cools on the 3s_{1/2}-3p_{3/2} transition, while the nearest blue-detuned comb line contributes negligible heating. We observe the cooling-heating transition and long-term cooling of ion chains with several sympathetically cooled ions. Spatial thermometry shows that the ion is cooled to near the Doppler limit. Doppler cooling with frequency combs has the potential to open many additional atomic species to laser cooling by reaching further into the vacuum and extreme ultraviolet via high-harmonic generation and by providing a broad bandwidth from which multiple excitation sidebands can be obtained.

  2. Improved technique for blood flow velocity measurement using Doppler effect

    NASA Astrophysics Data System (ADS)

    Valadares Oliveira, Eduardo J.; Nantes Button, Vera L. d. S.; Maia, Joaquim M.; Costa, Eduardo T.

    2002-04-01

    The Doppler velocimeter developed allows to determine the angle between the ultrasonic beam and the velocity vector of the flow, and to calculate the precise blood flow in a vessel. Four piezoelectric transducers constitute the Doppler velocimeter. Three of these transducers are positioned to form an equilateral triangle (base of a pyramid). When these transducers move simultaneously, backward or forward from the initial position, the emitted ultrasonic beams focalize on a position (peak of the pyramid) closer or farther from the transducers faces, according to the depth of the vessel where we intend to measure de flow. The angle between the transducers allows adjusting the height of this pyramid and the position of the focus (where the three beams meet). A forth transducer is used to determine the diameter of the vessel and monitor the position of the Doppler velocimeter relative to the vessel. Simulation results showed that with this technique is possible to accomplish precise measurement of blood flow.

  3. One way Doppler Extractor. Volume 2: Digital VCO technique

    NASA Technical Reports Server (NTRS)

    Nossen, E. J.; Starner, E. R.

    1974-01-01

    A feasibility analysis and trade-offs for a one-way Doppler extractor using digital VCO techniques is presented. The method of Doppler measurement involves the use of a digital phase lock loop; once this loop is locked to the incoming signal, the precise frequency and hence the Doppler component can be determined directly from the contents of the digital control register. The only serious error source is due to internally generated noise. Techniques are presented for minimizing this error source and achieving an accuracy of 0.01 Hz in a one second averaging period. A number of digitally controlled oscillators were analyzed from a performance and complexity point of view. The most promising technique uses an arithmetic synthesizer as a digital waveform generator.

  4. Phase relation recovery for scanning laser Doppler vibrometry

    NASA Astrophysics Data System (ADS)

    Alveringh, D.; Sanders, R. G. P.; Wiegerink, R. J.; Lötters, J. C.

    2017-02-01

    Laser Doppler vibrometers are able to measure the velocity of a single point compared to a reference point by analyzing the Doppler shift of the laser beams. In many commercially available laser Doppler vibrometers, the laser point can be scanned to obtain an out-of-plane velocity profile of a surface. It is essential that the phase information of the velocities between points is measured as well to be able to fully reproduce the velocity profile of the surface. If this cannot be done by triggering on the actuation signal, the proposed two stage method can be used. This method measures the surface in two stages: one scan with the reference beam at a fixed point and one scan with the reference beam on a moving point. The algorithm in this article calculates the phase and reconstructs the velocity of each point. This is experimentally verified on three different micro structures. The postprocessing algorithm is not intensive in computing power.

  5. All-sky Doppler interferometer for thermospheric dynamics studies

    NASA Astrophysics Data System (ADS)

    Biondi, Manfred A.; Zipf, Mark E.; Sipler, Dwight P.; Baumgardner, Jeffrey L.

    1995-04-01

    An efficient, all-sky input optical system has been mated to a 100-mm-aperture Fabry-Perot interferometer that employs a cooled (-150 deg C) CCD as a photon detector to create an all-sky Doppler interferom-eter. The instrument is capable of simultaneously measuring Doppler shifts and widths of nightglow emission lines from many different points in the sky, thereby providing determinations of upper-atmosphere neutral wind and temperature fields over a large region (to approximately equals 2000 km in extent). For OI 630-nm (thermosphere) and OH 799.6-nm (mesopause) nightglow emissions, exposure times of 5-15 min provide good-quality interferometric images. The capability of the all-sky Doppler interferometer is illustrated by examples of thermospheric wind and temperature fields measured over Millstone Hill, Massachusetts.

  6. UltraFast Doppler ultrasonography for hepatic vessels of liver recipients: preliminary experiences

    PubMed Central

    2015-01-01

    Purpose: The purpose of this study was to investigate the value of UltraFast Doppler ultrasonography (US) for evaluating hepatic vessels in liver recipients. Methods: Thirty-nine liver Doppler US sessions were conducted in 20 liver recipients. Each session consisted of UltraFast and conventional liver Doppler US in a random order. We compared the velocities and phasicities of the hepatic vessels, duration of each Doppler study, occurrence of technical failures, and differences in clinical decisions. Results: The velocities and resistive index values of hepatic vessels showed a strong positive correlation between the two Doppler studies (mean R=0.806; range, 0.710 to 0.924). The phasicities of the hepatic vessels were the same in both Doppler US exams. With respect to the duration of the Doppler US exam, there was no significant difference between the UltraFast (251±99 seconds) and conventional (231±117 seconds) Doppler studies (P=0.306). In five poor breath-holders, in whom the duration of conventional Doppler US was longer, UltraFast Doppler US (272±157 seconds) required a shorter time than conventional Doppler US (381±133 seconds; P=0.005). There was no difference between the two techniques with respect to technical failures and clinical decisions. Conclusion: UltraFast Doppler US is clinically equivalent to conventional Doppler US with advantages for poor breath-holders during the post-liver transplantation work-up. PMID:25409662

  7. Doppler displacements in kink MHD waves in solar flux tubes

    NASA Astrophysics Data System (ADS)

    Goossens, Marcel; Van Doorsselaere, Tom; Terradas, Jaume; Verth, Gary; Soler, Roberto

    Doppler displacements in kink MHD waves in solar flux tubes Presenting author: M. Goossens Co-authors: R. Soler, J. Terradas, T. Van Doorsselaere, G. Verth The standard interpretation of the transverse MHD waves observed in the solar atmosphere is that they are non-axisymmetric kink m=1) waves on magnetic flux tubes. This interpretation is based on the fact that axisymmetric and non-axisymmetric fluting waves do not displace the axis of the loop and the loop as a whole while kink waves indeed do so. A uniform transverse motion produces a Doppler displacement that is constant across the magnetic flux tube. A recent development is the observation of Doppler displacements that vary across the loop. The aim of the present contribution is to show that spatial variations of the Doppler displacements across the loop can be caused by kink waves. The motion associated with a kink wave is purely transverse only when the flux tube is uniform and sufficiently thin. Only in that case do the radial and azimuthal components of displacement have the same amplitude and is the azimuthal component a quarter of a period ahead of the radial component. This results in a unidirectional or transverse displacement. When the flux tube is non-uniform and has a non-zero radius the conditions for the generation of a purely transverse motion are not any longer met. In that case the motion in a kink wave is the sum of a transverse motion and a non-axisymmetric rotational motion that depends on the azimuthal angle. It can produce complicated variations of the Doppler displacement across the loop. I shall discuss the various cases of possible Doppler displacenents that can occur depending on the relative sizes of the amplitudes of the radial and azimuthal components of the displacement in the kink wave and on the orientation of the line of sight.

  8. A new clutter rejection algorithm for Doppler ultrasound.

    PubMed

    Cloutier, Guy; Chen, Danmin; Durand, Louis-Gilles

    2003-04-01

    Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): time-varying low-frequency components, covering systole and early diastole, and short transient clutter signals, distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted from the time-domain signal s(n) until the signal-to-clutter (S/C) ratio reached a maximum. For the low-frequency clutter signal, the improvement in S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient clutter signal, ten atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. The performance of the MP method was also tested on real data recorded over the common carotid artery of a normal subject. Removing 15 atoms significantly improved the appearance of the Doppler sonogram contaminated with low-frequency clutter. Many more atoms (over 200) were required to remove transient clutter components. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

  9. Browsing a wealth of millimeter-wavelength doppler spectra data

    SciTech Connect

    Johnson,K.; Luke,E.; Kollias, P.; Remillard, J.; Widener, K.; Jensen, M.

    2010-03-15

    The ARM Climate Research Facility has collected an extensive archive of vertically pointing millimeter wavelength Doppler radar spectra at both 35 and 95 GHz. These data are a rich potential source of detailed microphysical and dynamical cloud and precipitation information. The recording of spectra, which is ongoing, began at the Southern Great Plains site in September of 2003, at the North Slope of Alaska site in April 2004, and at Tropical Western Pacific sites in 2006. Spectra are also being collected during ARM Mobile Facility deployments. The data’s temporal resolution is as high as two seconds, at height intervals of 45 to 90 m. However, the sheer volume of available data can be somewhat daunting to access and search for specific features of interest. Here we present a user interface for spectra browsing, which allows the user to view time-height images of radar moments, select a time or height of interest, and then “drill down” through images of spectrograms to individual Doppler spectra or time- and height-sequences of spectra. Also available are images summarizing spectral characteristics, such as number of spectral peaks, spectral shape information (skewness and kurtosis), moment uncertainty estimates, and hydrometeor vs. clutter identification as produced by the ARM MicroARSCL (Microphysical Active Remote Sensing of Clouds) value-added product. In addition to the access and visualization tools, we are developing a Doppler spectra simulator capable of generating Doppler spectra from liquid, mixed-phase, and solid cloud constituents and precipitation. The Doppler spectra simulator can be used as an interface between explicit microphysics models and Doppler spectra observations from the ARM radars. The plan is to ultimately make the spectra simulator available from within the spectra browser, allowing a user to associate observed spectra with the microphysical conditions capable of producing them.

  10. Reducing Antenna Mechanical Noise in Precision Doppler Tracking

    NASA Astrophysics Data System (ADS)

    Armstrong, J. W.; Estabrook, F. B.; Asmar, S. W.; Iess, L.; Tortora, P.

    2006-05-01

    Precision Doppler tracking of deep-space probes is central to spacecraft navigation and many radio science investigations. The most sensitive Doppler observations to date have been taken using the NASA/JPL Deep Space Network (DSN) antenna DSS 25, a 34-m-diameter beam-waveguide station especially instrumented with simultaneous X-band (approximately 8.4-GHz) and Ka-band (approximately 32-GHz) links and tropospheric scintillation calibration equipment, tracking the Cassini spacecraft. These Cassini observations achieved Doppler fractional frequency stability (Doppler frequency fluctuation divided by center frequency, Delta f / f_o ) of approximately 3 x 10^-15 at tau = 1000 s integration. In those very-high-sensitivity tracks, the leading disturbance was antenna mechanical noise: time-dependent unmodeled physical motion of the ground antenna's phase center caused by antenna sag as the elevation angle changed, unmodeled subreflector motion, wind loading, bulk motion of the antenna as it rolled over irregularities in the supporting azimuth ring, differential thermal expansion of the structure, etc. This noise has seemed irreducible at reasonable cost, since it is unclear how to build a practical, large, moving, steel structure having mechanical stability significantly better than that of current tracking stations. Here we show how the mechanical noise of a large tracking antenna can effectively be removed when two-way Doppler tracking data from an existing DSN antenna are suitably combined with simultaneous tracking data using an ancillary (smaller and stiffer) antenna. Using our method, the mechanical noise in the final Doppler observable can be reduced, substantially, to that of the stiffer antenna.

  11. Single pass Doppler positioning for Search and Rescue satellite missions

    NASA Technical Reports Server (NTRS)

    Schmid, P. E.; Vonbun, F. O.; Lynn, J. J.

    1976-01-01

    This paper describes the implementation of beacon location experiments involving the NASA Nimbus-6 and the Amateur Satellite Corporation (AMSAT) Oscar-6 and Oscar-7 spacecraft. The purpose of these experiments is to demonstrate the feasibility of determining the geographical location of a low power VHF 'distress beacon' via satellite. Doppler data collected during satellite passes is reduced in a mini-computer by means of a simple algorithm resulting in the simultaneous recovery of the unknown receiver coordinates and the unknown Doppler bias frequency. Results indicate point positioning to within a few kilometers - which is within the required accuracies for the positioning of downed aircraft for Search/Rescue missions.

  12. Quantum interference of biphotons with a Doppler frequency shift

    NASA Astrophysics Data System (ADS)

    Lariontsev, E. G.

    2016-08-01

    We report a theoretical study of transformation of a biphoton state of light under Bragg diffraction on a travelling sound wave in an acousto-optic modulator (AOM). It is shown that the diffraction of AOM biphotons emitted during the collinear parametric scattering of light leads to a shift of the carrier frequency of a biphoton wave packet, which exceeds twice the Doppler frequency shift for the classical field. A method is proposed for measuring the Doppler frequency shift of a biphoton, which is based on interference between independent biphotons.

  13. Aerial ultrasonic micro Doppler sonar detection range in outdoor environments.

    PubMed

    Bradley, Marshall; Sabatier, James M

    2012-03-01

    Current research demonstrates that micro Doppler sonar has the capability to uniquely identify the presence of a moving human, making it an attractive component in surveillance systems for border security applications. Primary environmental factors that limit sonar performance are two-way spreading losses, ultrasonic absorption, and backscattered energy from the ground that appears at zero Doppler shift in the sonar signal processor. Spectral leakage from the backscatter component has a significant effect on sonar performance for slow moving targets. Sonar performance is shown to rapidly decay as the sensor is moved closer to the ground due to increasing surface backscatter levels.

  14. Barker code pulse compression with a large Doppler tolerance

    NASA Astrophysics Data System (ADS)

    Jiang, Xuefeng; Zhu, Zhaoda

    1991-03-01

    This paper discusses the application of least square approximate inverse filtering techniques to radar range sidelobe suppression. The method is illustrated by application to the design of a compensated noncoherent sidelobe suppression filter (SSF). The compensated noncoherent SSF of the 13-element Barker code has been found. The -40 kHz to 40 kHz Doppler tolerance of the filter is obtained under the conditions that the subpulse duration is equal to 0.7 microsec and the peak sidelobe level is less than -30 dB. Theoretical computations and experimental results indicate that the SSF implemented has much wider Doppler tolerance than the Rihaczek-Golden (1971) SSF.

  15. Doppler shifted H Ly alpha emission from Jupiter's aurora

    NASA Technical Reports Server (NTRS)

    Clarke, John T.; Trauger, John; Waite, J. Hunter, Jr.

    1989-01-01

    High-spectral-resolution IUE observations of the aurora on Jupiter were obtained in order to search for Doppler shifted H-Ly-alpha emission produced through charge exchange by fast precipitating protons. Although no emission has been observed corresponding to proton energies greater than 200 eV, a large fraction of the H-Ly-alpha emission has appeared Doppler shifted, mainly toward the blue, by about 50 km/s. These results show that the acceleration of ionospheric plasma in an H2 atmosphere can lead to bright Ly-alpha emission, setting constraints on the production of the outer planet airglow emissions.

  16. Grayscale and Color Doppler Features of Testicular Lymphoma

    PubMed Central

    Bertolotto, Michele; Derchi, Lorenzo E.; Secil, Mustafa; Dogra, Vikram; Sidhu, Paul S.; Clements, Richard; Freeman, Simon; Grenier, Nicolas; Mannelli, Lorenzo; Ramchandani, Parvati; Cicero, Calogero; Abete, Luca; Bussani, Rossana; Rocher, Laurence; Spencer, John; Tsili, Athina; Valentino, Massimo; Pavlica, Pietro

    2016-01-01

    Pooled data from 16 radiology centers were retrospectively analyzed to seek patients with pathologically proven testicular lymphoma and grayscale and color Doppler images available for review. Forty-three cases were found: 36 (84%) primary and 7 (16%) secondary testicular lymphoma. With unilateral primary lymphoma, involvement was unifocal (n = 10), multifocal (n = 11), or diffuse (n = 11). Synchronous bilateral involvement occurred in 6 patients. Color Doppler sonography showed normal testicular vessels within the tumor in 31 of 43 lymphomas (72%). Testicular lymphoma infiltrates through the tubules, preserving the normal vascular architecture of the testis. Depiction of normal testicular vessels crossing the lesion is a useful adjunctive diagnostic criterion. PMID:26014335

  17. Doppler echocardiographic parameters of evaluation of left ventricular systolic function.

    PubMed

    Drăgulescu, S I; Roşu, D; Abazid, J; Ionac, A

    1993-01-01

    The authors suggest a new method using Doppler echocardiography for the evaluation of cardiac performance. Doppler echocardiography permits the calculation of left ventricular (LV) ejection force (according to Newton's second law of motion). The ejection force was calculated in 36 patients with heart failure subgrouped into 3 groups based on ejection fraction (EF) (> 60%; 41-60%; < 40%) compared to 11 normal subjects. The LV ejection force showed a good linear correlation with LV ejection fraction (r = 0.86). Data of the study suggest that the LV ejection force is a valuable and accurate index for the assessment of cardiac performance, especially in early stages of disease.

  18. Method and apparatus for Doppler frequency modulation of radiation

    NASA Technical Reports Server (NTRS)

    Margolis, J. S.; Mccleese, D. J.; Shumate, M. S.; Seaman, C. H. (Inventor)

    1980-01-01

    A method and apparatus are described for frequency modulating radiation, such as from a laser, for optoacoustic detectors, interferometers, heterodyne spectrometers, and similar devices. Two oppositely reciprocating cats-eye retroreflectors are used to Doppler modulate the radiation. By reciprocally moving both retroreflectors, the center of mass is maintained constant to permit smooth operation at many Hertz. By slightly offsetting the axis of one retroreflector relative to the other, multiple passes of a light beam may be achieved for greater Doppler shifts with the same reciprocating motion of the retroreflectors.

  19. Color Doppler Imaging of Cardiac Catheters Using Vibrating Motors

    PubMed Central

    Reddy, Kalyan E.; Light, Edward D.; Rivera, Danny J.; Kisslo, Joseph A.; Smith, Stephen W.

    2010-01-01

    We attached a miniature motor rotating at 11,000 rpm onto the proximal end of cardiac electrophysiological (EP) catheters in order to produce vibrations at the tip which were then visualized by color Doppler on ultrasound scanners. We imaged the catheter tip within a vascular graft submerged in a water tank using the Volumetrics Medical Imaging 3D scanner, the Siemens Sonoline Antares 2D scanner, and the Philips ie33 3D ultrasound scanner with TEE probe. The vibrating catheter tip was visualized in each case though results varied with the color Doppler properties of the individual scanner. PMID:19514134

  20. Power Doppler ultrasound appearances of neonatal ischaemic brain injury.

    PubMed

    Steventon, D M; John, P R

    1997-02-01

    Following neonatal ischaemic brain injury, irregular vessels increase in size owing to luxury perfusion. These may be demonstrated by conventional colour flow Doppler (CFD) imaging at the periphery of the infarcted area. We present a case in which power Doppler imaging (PDI) was performed in addition to CFD in a neonate with unexplained seizures and which proved more sensitive than CFD in demonstrating luxury perfusion. Ultrasound appearances were compared with those seen on cranial CT. PDI can be a useful adjunct to conventional CFD examination of the neonatal brain in cerebral infarction.

  1. Imaging doppler lidar for wind turbine wake profiling

    DOEpatents

    Bossert, David J.

    2015-11-19

    An imaging Doppler lidar (IDL) enables the measurement of the velocity distribution of a large volume, in parallel, and at high spatial resolution in the wake of a wind turbine. Because the IDL is non-scanning, it can be orders of magnitude faster than conventional coherent lidar approaches. Scattering can be obtained from naturally occurring aerosol particles. Furthermore, the wind velocity can be measured directly from Doppler shifts of the laser light, so the measurement can be accomplished at large standoff and at wide fields-of-view.

  2. Multigroup Free-atom Doppler-broadening Approximation. Theory

    SciTech Connect

    Gray, Mark Girard

    2015-11-06

    Multigroup cross sections at a one target temperature can be Doppler-broadened to multigroup cross sections at a higher target temperature by matrix multiplication if the group structure suf- ficiently resolves the original temperature continuous energy cross section. Matrix elements are the higher temperature group weighted averages of the integral over the lower temperature group boundaries of the free-atom Doppler-broadening kernel. The results match theory for constant and 1/v multigroup cross sections at 618 lanl group structure resolution.

  3. C IV Doppler shifts observed in active region filaments

    NASA Technical Reports Server (NTRS)

    Klimchuk, J. A.

    1986-01-01

    The Doppler shift properties of 21 active region filaments were studied using C IV Dopplergram data. Most are associated with corridors of weak magnetic field that separate opposite polarity strong fields seen in photospheric magnetograms. A majority of the filaments are relatively blue shifted, although several lie very close to the dividing lines between blue and red shift. Only one filament in the samples is clearly red shifted. A new calibration procedure for Dopplergrams indicates that sizable zero point offsets are often required. The center-to-limb behavior of the resulting absolute Doppler shifts suggests that filament flows are usually quite small. It is possible that they vanish.

  4. Miniature Laser Doppler Velocimeter for Measuring Wall Shear

    NASA Technical Reports Server (NTRS)

    Gharib, Morteza; Modarress, Darius; Forouhar, Siamak; Fourguette, Dominique; Taugwalder, Federic; Wilson, Daniel

    2005-01-01

    A miniature optoelectronic instrument has been invented as a nonintrusive means of measuring a velocity gradient proportional to a shear stress in a flow near a wall. The instrument, which can be mounted flush with the wall, is a variant of a basic laser Doppler velocimeter. The laser Doppler probe volume can be located close enough to the wall (as little as 100 micron from the surface) to lie within the viscosity-dominated sublayer of a turbulent boundary layer. The instrument includes a diode laser, the output of which is shaped by a diffractive optical element (DOE) into two beams that have elliptical cross sections with very high aspect ratios.

  5. Stretched-exponential Doppler spectra in underwater acoustic communication channels.

    PubMed

    van Walree, P A; Jenserud, T; Otnes, R

    2010-11-01

    The theory of underwater sound interacting with the sea surface predicts a Gaussian-spread frequency spectrum in the case of a large Rayleigh parameter. However, recent channel soundings reveal more sharply peaked spectra with heavier tails. The measured Doppler spread increases with the frequency and differs between multipath arrivals. The overall Doppler spectrum of a broadband waveform is the sum of the spectra of all constituent paths and frequencies, and is phenomenologically described by a stretched or compressed exponential. The stretched exponential also fits well to the broadband spectrum of a single propagation path, and narrowband spectra summed over all paths.

  6. [Echocardiographic and Doppler echocardiographic characterization of left ventricular diastolic function].

    PubMed

    Muscholl, M; Dennig, K; Kraus, F; Rudolph, W

    1990-12-01

    For noninvasive assessment of diastolic ventricular function, in addition to echocardiography, more recently, in particular, Doppler echocardiography has been employed. M-mode echocardiogram velocity curves for diameter changes as well as Doppler-echocardiographically registered velocity curves of mitral flow characterize the temporal changes of diastolic flow into the left ventricle. They represent the overall result of factors which influence diastolic filling and are functions of the temporal course of the pressure difference between left atrium and left ventricle. Registration of M-mode and Doppler echocardiograms: For determination of M-mode parameters which should describe left ventricular diastolic function, in addition to the motion of the mitral valve, the left ventricular contours of septum and posterior wall between mitral leaflets and papillary muscles are recorded together with the ECG. For evaluation of the index of atrial emptying, an M-mode registration is obtained from the region of the aortic root. Determination of the Doppler echocardiographic parameters is based on analysis of the blood flow velocity in the region of the mitral valve in the apical four-chamber view with the pulsed Doppler method. Additionally, simultaneous to the Doppler curve, a phonocardiogram is registered or, alternatively, a continuous-wave Doppler registration is obtained which delineates the left ventricular outflow signal and the artefact of mitral valve opening. Parameters for characterization of left ventricular diastolic filling: The first peak of the velocity curve of the diameter change in the M-mode echocardiogram corresponds with the maximal diameter change resulting from early-diastolic filling and the second peak with the maximal diameter change of the left ventricle associated with atrial filling. From this curve as well as the diameter curve relative to time and the mitral valve motion, the times for isovolumetric relaxation as well as the rapid, slow and

  7. Doppler and range determination for deep space vehicles using active optical transponders

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.; Gagliardi, Robert M.

    1988-01-01

    This paper describes and analyzes two types of laser system employing active transponders that could accurately determine Doppler and range to deep space vehicles from earth-orbiting satellites. The first is a noncoherent optical system in which the Doppler effect on an intensity-modulating subcarrier is measured. The second is a coherent optical system in which the Doppler effect of the optical carrier itself is measured. Doppler and range measurement errors are mathematically modeled and, for three example systems, numerically evaluated.

  8. Analysis of Doppler Lidar Data Acquired During the Pentagon Shield Field Campaign

    DTIC Science & Technology

    2011-04-01

    two coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to characterize the...Observations from two coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to... coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to characterize the overall

  9. Research on Fast-Doppler-Broadening of neutron cross sections

    SciTech Connect

    Li, S.; Wang, K.; Yu, G.

    2012-07-01

    A Fast-Doppler-Broadening method is developed in this work to broaden Continuous Energy neutron cross-sections for Monte Carlo calculations. Gauss integration algorithm and parallel computing are implemented in this method, which is unprecedented in the history of cross section processing. Compared to the traditional code (NJOY, SIGMA1, etc.), the new Fast-Doppler-Broadening method shows a remarkable speedup with keeping accuracy. The purpose of using Gauss integration is to avoid complex derivation of traditional broadening formula and heavy load of computing complementary error function that slows down the Doppler broadening process. The OpenMP environment is utilized in parallel computing which can take full advantage of modern multi-processor computers. Combination of the two can reduce processing time of main actinides (such as {sup 238}U, {sup 235}U) to an order of magnitude of 1{approx}2 seconds. This new method is fast enough to be applied to Online Doppler broadening. It can be combined or coupled with Monte Carlo transport code to solve temperature dependent problems and neutronics-thermal hydraulics coupled scheme which is a big challenge for the conventional NJOY-MCNP system. Examples are shown to determine the efficiency and relative errors compared with the NJOY results. A Godiva Benchmark is also used in order to test the ACE libraries produced by the new method. (authors)

  10. A range-rate extraction unit for determining Doppler effect

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Active ranging technique devised for VHF or S-band radar systems divides target Doppler frequency by counter-generated number that is proportional to transmitting frequency, thus producing target velocity data in terms of speed and distance relative to target transponder.

  11. Doppler optical mixing spectroscopy in multiparticle scattering fluids

    SciTech Connect

    Dubnishchev, Yu N

    2011-03-31

    We discuss the basic scheme of laser Doppler optical mixing spectroscopy for the analysis of media with multiparticle scattering. It is shown that the Rayleigh scheme, in contrast to the heterodyne and differential schemes, is insensitive to the effects of multiparticle scattering. (laser applications and other aspects of quantum electronics)

  12. [Myocardial function analysis with echocardiography-Doppler in septic shock].

    PubMed

    Fayssoil, A; Checinski, A

    2012-02-01

    Septic shock is a severe sepsis associated with cardio-circulatory failure and tissular hypoperfusion. Echocardiography-Doppler remains essential for the assessment of myocardial function in septic shock. This ultrasound procedure helps clinicians for the analysis of left ventricular systolic function, left ventricular diastolic function, right ventricular function and cardiac filling.

  13. Anomaly Detection In Additively Manufactured Parts Using Laser Doppler Vibrometery

    SciTech Connect

    Hernandez, Carlos A.

    2015-09-29

    Additively manufactured parts are susceptible to non-uniform structure caused by the unique manufacturing process. This can lead to structural weakness or catastrophic failure. Using laser Doppler vibrometry and frequency response analysis, non-contact detection of anomalies in additively manufactured parts may be possible. Preliminary tests show promise for small scale detection, but more future work is necessary.

  14. Validar: A Testbed for Advanced 2-Micron Doppler Lidar

    NASA Technical Reports Server (NTRS)

    Koch, Grady J.; Petros, Mulugeta; Barnes, Bruce W.; Beyon, Jeffrey Y.; Amzajerdian, Farzin; Yu, Jirong; Kavaya, Michael J.; Singh, Upendra N.

    2004-01-01

    High-energy 2-microns lasers have been incorporated in a breadboard coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Sample data is presented on wind profiling and CO2 concentration measurements.

  15. Reliability of Doppler sonography in extracranial cerebro-vascular stenosis.

    PubMed

    Colon, E J; de Weerd, J P; Notermans, S L; Vingerhoets, H M

    1979-01-01

    Of our patients who underwent quantitative Doppler sonography (Haemato-Tacho-Graphy), 382 underwent carotid angiography and 61 vertebral artery angiography. The reliability of the method proved to be between 90 and 95 percent for carotid as well as for vertebral arteries. The HTG proved to be a useful addition to angiography in patients with extracranial cerebro-vascular stenosis.

  16. Language Lateralization in Children Using Functional Transcranial Doppler Sonography

    ERIC Educational Resources Information Center

    Haag, Anja; Moeller, Nicola; Knake, Susanne; Hermsen, Anke; Oertel, Wolfgang H.; Rosenow, Felix; Hamer, Hajo M.

    2010-01-01

    Aim: Language lateralization with functional transcranial Doppler sonography (fTCD) and lexical word generation has been shown to have high concordance with the Wada test and functional magnetic resonance imaging in adults. We evaluated a nonlexical paradigm to determine language dominance in children. Method: In 23 right-handed children (12…

  17. Wing tip vortex measurements with laser Doppler systems

    NASA Technical Reports Server (NTRS)

    Fuller, C. E., III

    1973-01-01

    The vortex velocity field produced by a rectangular wing in a subsonic wind tunnel was measured using two laser Doppler velocimeter systems. One system made three dimensional mean velocity measurements and the other made one dimensional turbulence measurements. The systems and test procedures are described and comparisons of the measurements are made. The data defined a strong spiral motion in the vortex formation process.

  18. Doppler shifts of radar return from the sea surface

    NASA Astrophysics Data System (ADS)

    Ermakov, S. A.; Kapustin, I. A.; Molkov, A. A.; Sergievskaya, I. A.; Shomina, O. V.

    2016-10-01

    Investigation of the Doppler shift of radar return from the sea surface is very important for better understanding of capabilities of exploitation of microwave radar for measuring velocities of marine currents. Here new field experiments carried out from a Platform on the Black Sea with a coherent X-band scatterometer, and a Doppler multifrequency (X- /C-/S-band) dual-polarized radar recently designed at IAP RAS are discussed. It is shown that the radar return contains both Bragg (polarized) and non polarized scattering components, presumably giving different contributions to radar Doppler shifts. Radar Doppler shifts were estimated using two different definitions as a) a frequency of the "centre of gravity" of an instantaneous radar return spectrum (ASIS) averaged over periods of dominant wind waves and b) the "centre of gravity" of the averaged over dominant wave periods spectrum (SAS). The ASIS and SAS values for both VV and HH-polarizations are shown to be different due to effects of radar backscatter modulation by dominant (long) wind waves. The radar Modulation Transfer Function (MTF) has been analyzed from experimental data and difference between SAS- and ASIS-values has been satisfactory explained using the measured MTF-values. It is obtained that experimental values of ASIS can be satisfactory described by the Bragg model despite the significant contribution of NP component to the radar backscatter. A physical explanation of the effect is given.

  19. Analysis of multiple scattering effects in optical Doppler tomography

    NASA Astrophysics Data System (ADS)

    Yura, Harold T.; Thrane, Lars; Andersen, Peter E.

    2005-08-01

    Optical Doppler tomography (ODT) combines Doppler velocimetry and optical coherence tomography (OCT) to obtain high-resolution cross-sectional imaging of particle flow velocity in scattering media such as the human retina and skin. Here, we present the results of a theoretical analysis of ODT where multiple scattering effects are included. The purpose of this analysis is to determine how multiple scattering affects the estimation of the depth-resolved localized flow velocity. Depth-resolved velocity estimates are obtained directly from the corresponding mean or standard deviation of the observed Doppler frequency spectrum. Thus, in the present analysis, the dependence of the mean and standard deviation of the Doppler shift on the scattering properties of the flowing medium are obtained. Taking the multiple scattering effects into account, we are able to explain previous measurements of depth-resolved retinal flow profiles where the influence of multiple scattering was observed [Yazdanfar et al., Opt. Lett. 25, 1448 (2000)]. To the best of our knowledge, no analytical model exists that are able to explain these observations.

  20. Analysis of multiple scattering effects in optical Doppler tomography

    NASA Astrophysics Data System (ADS)

    Yura, Harold T.; Thrane, Lars; Andersen, Peter E.

    2005-04-01

    Optical Doppler tomography (ODT) combines Doppler velocimetry and optical coherence tomography (OCT) to obtain high-resolution cross-sectional imaging of particle flow velocity in scattering media such as the human retina and skin. Here, we present the results of a theoretical analysis of ODT where multiple scattering effects are included. The purpose of this analysis is to determine how multiple scattering affects the estimation of the depth-resolved localized flow velocity. Depth-resolved velocity estimates are obtained directly from the corresponding mean or standard deviation of the observed Doppler frequency spectrum. Thus, in the present analysis, the dependence of the mean and standard deviation of the Doppler shift on the scattering properties of the flowing medium are obtained. Taking the multiple scattering effects into account, we are able to explain previous measurements of depth-resolved retinal flow profiles where the influence of multiple scattering was observed [Yazdanfar et al., Opt. Lett. 25, 1448 (2000)]. To the best of our knowledge, no analytical model exists that are able to explain these observations.

  1. High-Energy 2-Micrometers Doppler Lidar for Wind Measurements

    NASA Technical Reports Server (NTRS)

    Koch, Grady J.; Beyon, Jeffrey Y.; Barnes, Bruce W.; Petros, Mulugeta; Yu, Jirong; Amzajerdian, Farzin; Kavaya, Michael J.; Singh, Upendra N.

    2006-01-01

    High-energy 2-micrometer wavelength lasers have been incorporated in a prototype coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Calibration tests and sample atmospheric data are presented on wind and aerosol profiling.

  2. Phase dynamics in a Doppler broadened optically-pumped laser

    NASA Astrophysics Data System (ADS)

    Roldán, E.; de Valcárcel, G. J.; Vilaseca, R.; Silva, F.; Pujol, J.; Corbalán, R.; Laguarta, F.

    1989-11-01

    The dynamic behavior of the phase of the generated field in a Doppler-broadened optically-pumped far-infrared laser is theoretically investigated for the first time. The phase undergoes sudden jumps of approximately π radians, which allow to establish the actual symmetry of the main attractor in the phase space, explaining the heteroclynic character of the chaotic behavior observed in experiments.

  3. Validar: a testbed for advanced 2-micron Doppler lidar

    NASA Astrophysics Data System (ADS)

    Koch, Grady J.; Petros, Mulugeta; Barnes, Bruce W.; Beyon, Jeffrey Y.; Amzajerdian, Farzin; Yu, Jirong; Kavaya, Michael J.; Singh, Upendra N.

    2004-09-01

    High-energy 2-micron lasers have been incorporated in a breadboard coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Sample data is presented on wind profiling and CO2 concentration measurements.

  4. Doppler velocimetric parameters of the testicular artery in healthy dogs.

    PubMed

    de Souza, Mírley Barbosa; da Cunha Barbosa, Claudia; Pereira, Barbara Sucupira; Monteiro, Cynthia Levi Baratta; Pinto, José Nicodemos; Linhares, Jussiara Candeira Spíndola; da Silva, Lúcia Daniel Machado

    2014-06-01

    This study aimed to examine the Doppler velocimetric pattern of the testicular artery of small dogs in two different locations. Testes of 21 dogs were evaluated by two-dimensional ultrasonography to measure testicular volume and by Doppler ultrasonography to record the velocimetric patterns of the testicular artery in the spermatic cord and marginal location. The volume of left testes (4.70 ± 1.22 cm(3)) was significantly higher than the volume of the right testes (4.45 ± 1.17 cm(3)). Peak systolic velocity (PSV) of the left spermatic cord was significantly higher than the right side. End-diastolic velocity was significantly higher in the marginal artery than the spermatic cord on both sides; however, resistance and pulsatility indexes were significantly lower in the marginal artery. Results demonstrate the viability of Doppler ultrasonography for characterization of the testicular artery in small dogs and Doppler velocimetric values vary according to the location of measurement along the artery.

  5. Robust estimation of fetal heart rate from US Doppler signals

    NASA Astrophysics Data System (ADS)

    Voicu, Iulian; Girault, Jean-Marc; Roussel, Catherine; Decock, Aliette; Kouame, Denis

    2010-01-01

    Introduction: In utero, Monitoring of fetal wellbeing or suffering is today an open challenge, due to the high number of clinical parameters to be considered. An automatic monitoring of fetal activity, dedicated for quantifying fetal wellbeing, becomes necessary. For this purpose and in a view to supply an alternative for the Manning test, we used an ultrasound multitransducer multigate Doppler system. One important issue (and first step in our investigation) is the accurate estimation of fetal heart rate (FHR). An estimation of the FHR is obtained by evaluating the autocorrelation function of the Doppler signals for ills and healthiness foetus. However, this estimator is not enough robust since about 20% of FHR are not detected in comparison to a reference system. These non detections are principally due to the fact that the Doppler signal generated by the fetal moving is strongly disturbed by the presence of others several Doppler sources (mother' s moving, pseudo breathing, etc.). By modifying the existing method (autocorrelation method) and by proposing new time and frequency estimators used in the audio' s domain, we reduce to 5% the probability of non-detection of the fetal heart rate. These results are really encouraging and they enable us to plan the use of automatic classification techniques in order to discriminate between healthy and in suffering foetus.

  6. Doppler Lidar in the Wind Forecast Improvement Projects

    NASA Astrophysics Data System (ADS)

    Pichugina, Yelena; Banta, Robert; Brewer, Alan; Choukulkar, Aditya; Marquis, Melinda; Olson, Joe; Hardesty, Mike

    2016-06-01

    This paper will provide an overview of some projects in support of Wind Energy development involving Doppler lidar measurement of wind flow profiles. The high temporal and vertical resolution of these profiles allows the uncertainty of Numerical Weather Prediction models to be evaluated in forecasting dynamic processes and wind flow phenomena in the layer of rotor-blade operation.

  7. Dual beam translator for use in Laser Doppler anemometry

    DOEpatents

    Brudnoy, D.M.

    1984-04-12

    A method and apparatus for selectively translating the path of at least one pair of light beams in a Laser Doppler anemometry device whereby the light paths are translated in a direction parallel to the original beam paths so as to enable attainment of spacial coincidence of the two intersection volumes and permit accurate measurements of Reynolds shear stress.

  8. Pediatric imaging/doppler ultrasound of the chest: Extracardiac diagnosis

    SciTech Connect

    Huhta, J.C.

    1986-01-01

    In this book the author spells out new diagnostic applications in pediatrics for high resolution cross-sectional ultrasonography, and demonstrates the ways in which Doppler techniques complement the cross-sectional method. This reference presents practical, step-by-step methods for non-invasive ultrasound examination of extra-cardiac anatomy and assessment of vascular blood flow.

  9. Airborne Wind Profiling Algorithm for Doppler Wind LIDAR

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y. (Inventor); Koch, Grady J. (Inventor); Kavaya, Michael J. (Inventor)

    2015-01-01

    Systems, methods, and devices of the present invention enable airborne Doppler Wind LIDAR system measurements and INS/GPS measurements to be combined to estimate wind parameters and compensate for instrument misalignment. In a further embodiment, the wind speed and wind direction may be computed based on two orthogonal line-of-sight LIDAR returns.

  10. How to Study the Doppler Effect with Audacity Software

    ERIC Educational Resources Information Center

    Dias, Marco Adriano; Carvalho, Paulo Simeão; Ventura, Daniel Rodrigues

    2016-01-01

    The Doppler effect is one of the recurring themes in college and high school classes. In order to contextualize the topic and engage the students in their own learning process, we propose a simple and easily accessible activity, i.e. the analysis of the videos available on the internet by the students. The sound of the engine of the vehicle…

  11. Coincidence doppler broadening study in electron-irradiated polyurethane

    NASA Astrophysics Data System (ADS)

    Yang, D. J.; Zhang, J. D.; Leung, J. K. C.; Beling, C. D.; Liu, L. B.

    2007-06-01

    Coincidence doppler broadening measurements on electron-irradiated polyurethanes were performed in the presence of air. It is shown that, after a certain electron irradiation, the momentum density distributions of annihilation electrons have obvious changes for the high crosslinking polyurethane, but no significant changes have been observed for the low crosslinking polyurethane. The results were performed to analyse by irradiation crosslinking and degradation principles.

  12. Multiplexed sub-Doppler spectroscopy with an optical frequency comb

    NASA Astrophysics Data System (ADS)

    Long, D. A.; Fleisher, A. J.; Plusquellic, D. F.; Hodges, J. T.

    2016-12-01

    An optical frequency comb generated with an electro-optic phase modulator and a chirped radio-frequency waveform is used to perform pump-probe spectroscopy on the D1 and D2 transitions of atomic potassium at 770.1 and 766.7 nm, respectively. With a comb tooth spacing of 200 kHz and an optical bandwidth of 2 GHz the hyperfine transitions can be observed simultaneously. Interferograms are recorded in as little as 5 µs (a timescale corresponding to the inverse of the comb tooth spacing). Importantly, the sub-Doppler features can be measured as long as the laser carrier frequency lies within the Doppler profile, thus removing the need for slow scanning or a priori knowledge of the frequencies of the sub-Doppler features. Sub-Doppler optical frequency comb spectroscopy has the potential to dramatically reduce acquisition times and allow for rapid and accurate assignment of complex molecular and atomic spectra which are presently intractable.

  13. Low Cost Coherent Doppler Lidar Data Acquisition and Processing

    NASA Technical Reports Server (NTRS)

    Barnes, Bruce W.; Koch, Grady J.

    2003-01-01

    The work described in this paper details the development of a low-cost, short-development time data acquisition and processing system for a coherent Doppler lidar. This was done using common laboratory equipment and a small software investment. This system provides near real-time wind profile measurements. Coding flexibility created a very useful test bed for new techniques.

  14. Multi-sensor Doppler radar for machine tool collision detection

    NASA Astrophysics Data System (ADS)

    Wächter, T. J.; Siart, U.; Eibert, T. F.; Bonerz, S.

    2014-11-01

    Machine damage due to tool collisions is a widespread issue in milling production. These collisions are typically caused by human errors. A solution for this problem is proposed based on a low-complexity 24 GHz continuous wave (CW) radar system. The developed monitoring system is able to detect moving objects by evaluating the Doppler shift. It combines incoherent information from several spatially distributed Doppler sensors and estimates the distance between an object and the sensors. The specially designed compact prototype contains up to five radar sensor modules and amplifiers yet fits into the limited available space. In this first approach we concentrate on the Doppler-based positioning of a single moving target. The recorded signals are preprocessed in order to remove noise and interference from the machinery hall. We conducted and processed system measurements with this prototype. The Doppler frequency estimation and the object position obtained after signal conditioning and processing with the developed algorithm were in good agreement with the reference coordinates provided by the machine's control unit.

  15. Doppler ultrasound and renal artery stenosis: An overview.

    PubMed

    Granata, A; Fiorini, F; Andrulli, S; Logias, F; Gallieni, M; Romano, G; Sicurezza, E; Fiore, C E

    2009-12-01

    Renovascular disease is a complex disorder, most commonly caused by fibromuscular dysplasia and atherosclerotic diseases. It can be found in one of three forms: asymptomatic renal artery stenosis (RAS), renovascular hypertension, and ischemic nephropathy. Particularly, the atherosclerotic form is a progressive disease that may lead to gradual and silent loss of renal function. Thus, early diagnosis of RAS is an important clinical objective since interventional therapy may improve or cure hypertension and preserve renal function. Screening for RAS is indicated in suspected renovascular hypertension or ischemic nephropathy, in order to identify patients in whom an endoluminal or surgical revascularization is advisable. Screening tests for RAS have improved considerably over the last decade. While captopril renography was widely used in the past, Doppler ultrasound (US) of the renal arteries (RAs), angio-CT, or magnetic resonance angiography (MRA) have replaced other modalities and they are now considered the screening tests of choice. An arteriogram is rarely needed for diagnostic purposes only. Color-Doppler US (CDUS) is a noninvasive, repeatable, relatively inexpensive diagnostic procedure which can accurately screen for renovascular diseases if performed by an expert. Moreover, the evaluation of the resistive index (RI) at Doppler US may be very useful in RAS affected patients for predicting the response to revascularization. However, when a discrepancy exists between clinical data and the results of Doppler US, additional tests are mandatory.

  16. Determining the Speed of Sound Using the Doppler Effect.

    ERIC Educational Resources Information Center

    Gagne, Richard.

    1996-01-01

    Presents a simple but effective experiment that uses ultrasonic transducers and some basic electronics to study the speed of sound using the Doppler effect. Eliminates the noise problems associated with most sound experiments. Discusses the theory, and describes the apparatus and procedure. (JRH)

  17. Noise Studies of Externally Dispersed Interferometry for Doppler Velocimetry

    SciTech Connect

    Erskine, D J; Edelstein, J; Lloyd, J; Muirhead, P

    2006-05-04

    Externally Dispersed Interferometry (EDI) is the series combination of a fixed-delay field-widened Michelson interferometer with a dispersive spectrograph. This combination boosts the spectrograph performance for both Doppler velocimetry and high resolution spectroscopy. The interferometer creates a periodic comb that multiplies against the input spectrum to create moire fringes, which are recorded in combination with the regular spectrum. Both regular and high-frequency spectral components can be recovered from the data--the moire component carries additional information that increases the signal to noise for velocimetry and spectroscopy. Here we present simulations and theoretical studies of the photon limited Doppler velocity noise in an EDI. We used a model spectrum of a 1600K temperature star. For several rotational blurring velocities 0, 7.5, 15 and 25 km/s we calculated the dimensionless Doppler quality index (Q) versus wavenumber v. This is the normalized RMS of the derivative of the spectrum and is proportional to the photon-limited Doppler signal to noise ratio.

  18. Fetal and umbilical Doppler ultrasound in high-risk pregnancies

    PubMed Central

    Alfirevic, Zarko; Stampalija, Tamara; Gyte, Gillian ML

    2014-01-01

    Background Abnormal blood flow patterns in fetal circulation detected by Doppler ultrasound may indicate poor fetal prognosis. It is also possible false positive Doppler ultrasound findings could encourage inappropriate early delivery. Objectives The objective of this review was to assess the effects of Doppler ultrasound used to assess fetal well-being in high-risk pregnancies on obstetric care and fetal outcomes. Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (September 2009) and the reference lists of identified studies. Selection criteria Randomised and quasi-randomised controlled trials of Doppler ultrasound for the investigation of umbilical and fetal vessels waveforms in high-risk pregnancies compared to no Doppler ultrasound. Data collection and analysis Two authors independently assessed the studies for inclusion, assessed risk of bias and carried out data extraction. Data entry was checked. Main results Eighteen completed studies involving just over 10,000 women were included. The trials were generally of unclear quality with some evidence of possible publication bias. The use of Doppler ultrasound in high-risk pregnancy was associated a reduction in perinatal deaths (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.52 to 0.98, 16 studies, 10,225 babies, 1.2% versus 1.7 %, numbers needed to treat = 203; 95%CI 103 to 4352). There were also fewer inductions of labour (average RR 0.89, 95% CI 0.80 to 0.99, 10 studies, 5633 women, random effects) and fewer caesarean sections (RR 0.90, 95% CI 0.84 to 0.97, 14 studies, 7918 women). No difference was found in operative vaginal births (RR 0.95, 95% CI 0.80 to 1.14, four studies, 2813 women) nor in Apgar scores less than seven at five minutes (RR 0.92, 95% CI 0.69 to 1.24, seven studies, 6321 babies). Authors’ conclusions Current evidence suggests that the use of Doppler ultrasound in high-risk pregnancies reduced the risk of perinatal deaths and resulted in less

  19. Non-Gaussianity and CMB aberration and Doppler

    SciTech Connect

    Catena, Riccardo; Liguori, Michele; Renzi, Alessandro; Notari, Alessio E-mail: michele.liguori@pd.infn.it E-mail: arenzi@pd.infn.it

    2013-09-01

    The peculiar motion of an observer with respect to the CMB rest frame induces a deflection in the arrival direction of the observed photons (also known as CMB aberration) and a Doppler shift in the measured photon frequencies. As a consequence, aberration and Doppler effects induce non trivial correlations between the harmonic coefficients of the observed CMB temperature maps. In this paper we investigate whether these correlations generate a bias on non-Gaussianity estimators f{sub NL}. We perform this analysis simulating a large number of temperature maps with Planck-like resolution (lmax = 2000) as different realizations of the same cosmological fiducial model (WMAP7yr). We then add to these maps aberration and Doppler effects employing a modified version of the HEALPix code. We finally evaluate a generalization of the Komatsu, Spergel and Wandelt non-Gaussianity estimator for all the simulated maps, both when peculiar velocity effects have been considered and when these phenomena have been neglected. Using the value v/c = 1.23 × 10{sup −3} for our peculiar velocity, we found that the aberration/Doppler induced non-Gaussian signal is at most of about half of the cosmic variance σ for f{sub NL} both in a full-sky and in a cut-sky experimental configuration, for local, equilateral and orthogonal estimators. We conclude therefore that when estimating f{sub NL} it is safe to ignore aberration and Doppler effects if the primordial map is already Gaussian. More work is necessary however to assess whether a map which contains non-Gaussianity can be significantly distorted by a peculiar velocity.

  20. Observation of Doppler broadening in β -delayed proton- γ decay

    DOE PAGES

    Schwartz, S. B.; Wrede, C.; Bennett, M. B.; ...

    2015-09-14

    Background: The Doppler broadening of gamma-ray peaks is due to nuclear recoil from beta-delayed nucleon emission can be used to measure the energies of the nucleons. This method has never been tested using beta-delayed proton emission or applied to a recoil heavier than A = 10. Purpose: To test and apply this Doppler broadening method using gamma-ray peaks from the P-26(beta p gamma)Al-25 decay sequence. Methods: A fast beam of P-26 was implanted into a planar Ge detector, which was used as a P-26 beta-decay trigger. The SeGA array of high-purity Ge detectors was used to detect gamma rays frommore » the P-26(beta p gamma)Al-25 decay sequence. Results: Radiative Doppler broadening in beta-delayed proton-gamma decay was observed for the first time. Moreover, the Doppler broadening analysis method was verified using the 1613-keV gamma-ray line for which the proton energies were previously known. The 1776-keV gamma ray de-exciting the 2720 keV Al-25 level was observed in P-26(beta p gamma)Al-25 decay for the first time and used to determine that the center-of-mass energy of the proton emission feeding the 2720-keV level is 5.1 +/- 1.0 (stat.) +/- 0.6 (syst.) MeV, corresponding to a Si-26 excitation energy of 13.3 +/- 1.0 (stat.) +/- 0.6 (syst.) MeV for the proton-emitting level. Conclusions: Finally, the Doppler broadening method has been demonstrated to provide practical measurements of the energies for beta-delayed nucleon emissions populating excited states of nuclear recoils at least as heavy as A = 25.« less

  1. Acute Effects of Lateral Thigh Foam Rolling on Arterial Tissue Perfusion Determined by Spectral Doppler and Power Doppler Ultrasound.

    PubMed

    Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U

    2017-04-01

    Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p < 0.001), in TAMx of 53.2% (p < 0.001) and 38.3% (p = 0.002), and in TAMn of 84.4% (p < 0.001) and 68.2% (p < 0.001). Semiquantitative power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.

  2. Micro-Doppler analysis of multiple frequency continuous wave radar signatures

    NASA Astrophysics Data System (ADS)

    Anderson, Michael G.; Rogers, Robert L.

    2007-04-01

    Micro-Doppler refers to Doppler scattering returns produced by non rigid-body motion. Micro-Doppler gives rise to many detailed radar image features in addition to those associated with bulk target motion. Targets of different classes (for example, humans, animals, and vehicles) produce micro-Doppler images that are often distinguishable even by nonexpert observers. Micro-Doppler features have great potential for use in automatic target classification algorithms. Although the potential benefit of using micro-Doppler in classification algorithms is high, relatively little experimental (non-synthetic) micro-Doppler data exists. Much of the existing experimental data comes from highly cooperative targets (human or vehicle targets directly approaching the radar). This research involved field data collection and analysis of micro-Doppler radar signatures from non-cooperative targets. The data was collected using a low cost Xband multiple frequency continuous wave (MFCW) radar with three transmit frequencies. The collected MFCW radar signatures contain data from humans, vehicles, and animals. The presented data includes micro-Doppler signatures previously unavailable in the literature such as crawling humans and various animal species. The animal micro-Doppler signatures include deer, dog, and goat datasets. This research focuses on the analysis of micro-Doppler from noncooperative targets approaching the radar at various angles, maneuvers, and postures.

  3. Spaceborne Simulations of Two Direct-Detection Doppler Lidar Techniques

    NASA Technical Reports Server (NTRS)

    McGill, Matthew J.; Li, Steve X.

    1998-01-01

    Direct-detection (or incoherent) lidar is now a proven technique for measuring winds in the atmosphere. Over the last few years, several types of direct-detection lidar have evolved. These methods rely on Fabry-Perot interferometers(also termed etalons) or other narrow-passband filters to provide the required spectral resolution. One method, now called the edge (EDG) technique, uses a sharply-sloping filter and measures changes in the filter transmission caused by Doppler shifting of the laser wavelength. A variation of the EDG method, called the double-edge (DEDG) technique, uses two filters. The molecular DEDG method was first demonstrated by Chanin et al. for stratospheric measurements and more recently Korb et al. successfully demonstrated the aerosol DEDG through the troposphere. A second method, here termed the multi-channel (MC) technique, measures Doppler shifts by observing angular displacement of a Fabry-Perot fringe in a spatially resolving detector. The EDG technique thus employs the Fabry-Perot to convert the frequency shift into an amplitude signal, while the MC technique uses the Fabry-Perot to resolve the spectral signature which is then fitted to determine the centroid. The focus of this presentation is on the DEDG and MC methods because these are viewed as the current state of the art in direct-detection lidar. Successful ground-based demonstrations of direct-detection wind measurements have resulted in proposals for spaceborne systems. With this new emphasis on spaceborne systems comes the need for accurate prediction of spaceborne direct-detection Doppler lidar performance. Previously, the EDG and MC methods have been compared although only for aerosol Doppler systems. A recent paper by McGill and Spinhirne compares the DEDG and MC methods in a non-system specific manner for both the aerosol and molecular Doppler systems. The purpose of this presentation is to extend the previous work of McGill and Spinhirne to examine the performance of

  4. Comparison between ultrasonographic findings of benign and malignant canine mammary gland tumours using B-mode, colour Doppler, power Doppler and spectral Doppler.

    PubMed

    Soler, Marta; Dominguez, Elisabet; Lucas, Xiomara; Novellas, Rosa; Gomes-Coelho, Kassia Valeria; Espada, Yvonne; Agut, Amalia

    2016-08-01

    The aim of this study was to evaluate whether the comparison between the ultrasonographic features of canine mammary tumours, assessed by B-Mode, colour Doppler, power Doppler, spectral Doppler, and histopathologic features, would help to differentiate if a tumour is benign or malignant. Ultrasonographic examinations of 104 tumours were performed. Volume, margins, presence of a capsule, echotexture and presence and distribution of the vascular flow of the tumours were evaluated. All the tumours were surgically removed, submitted for histopathologic examination and classified in two groups: Group I (benign tumours) and Group II (malignant tumours). Echotexture was the only parameter evaluated by B-Mode ultrasonography where significant differences were found (p<0.01), with tumours in Group I being homogeneous and tumours in Group II presenting greater heterogeneity. Presence of vascular flow was observed in most of the tumours from both groups and no differences between them were found. Regarding flow distribution, significant differences were observed between groups (p<0.05). In benign tumours, the most common vascular pattern was the peripheral, showing significant differences (p<0.05) compared to mixed and central patterns. In malignant tumours the mixed pattern was the most frequent. Also significant differences among other patterns (peripheral and central) were found. Concerning vascular resistivity and pulsatility indexes, there were no significant differences between the two groups. The echotexture and type of vascular flow pattern of canine mammary gland tumours may help, in a first examination of the tumour, to differentiate between benign and malignant tumours; however to reach a definitive diagnosis histological study is required.

  5. Doppler Lidar Vertical Velocity Statistics Value-Added Product

    SciTech Connect

    Newsom, R. K.; Sivaraman, C.; Shippert, T. R.; Riihimaki, L. D.

    2015-07-01

    Accurate height-resolved measurements of higher-order statistical moments of vertical velocity fluctuations are crucial for improved understanding of turbulent mixing and diffusion, convective initiation, and cloud life cycles. The Atmospheric Radiation Measurement (ARM) Climate Research Facility operates coherent Doppler lidar systems at several sites around the globe. These instruments provide measurements of clear-air vertical velocity profiles in the lower troposphere with a nominal temporal resolution of 1 sec and height resolution of 30 m. The purpose of the Doppler lidar vertical velocity statistics (DLWSTATS) value-added product (VAP) is to produce height- and time-resolved estimates of vertical velocity variance, skewness, and kurtosis from these raw measurements. The VAP also produces estimates of cloud properties, including cloud-base height (CBH), cloud frequency, cloud-base vertical velocity, and cloud-base updraft fraction.

  6. Novel Doppler laser radar for diagnostics in fusion reactors

    SciTech Connect

    Menon, Madhavan; Slotwinski, Anthony

    2004-10-01

    We describe the development of a novel Doppler laser radar (DOLAR) for remote measurement of flow velocity (0-10 m/s) and film thickness of liquid metal walls, currently being studied for their superior heat handling and self-healing characteristics. Small fluctuations in flow velocity({approx}mm/s) and flow thickness ({approx}50 {mu}m) that may arise during plasma discharges can also be measured. The DOLAR is also designed for non intrusive mapping of features of plasma-facing solid surfaces with very high precision ({approx}50 {mu}m). It can also measure the motion of structural components of a fusion reactor during plasma discharges and during plasma disruptions. The device utilizes frequency modulation laser radar principles for precision range measurements. Compensation of Doppler frequency shift is used to measure flow velocity. The DOLAR probe head is designed with acousto-optic and piezoelectric devices for operation in the harsh fusion environment.

  7. Laser Doppler velocimeter system simulation for sensing aircraft wake vortices

    NASA Technical Reports Server (NTRS)

    Thomson, J. A. L.; Meng, J. C. S.

    1974-01-01

    A hydrodynamic model of aircraft vortex wakes in an irregular wind shear field near the ground is developed and used as a basis for modeling the characteristics of a laser Doppler detection and vortex location system. The trailing vortex sheet and the wind shear are represented by discrete free vortices distributed over a two-dimensional grid. The time dependent hydrodynamic equations are solved by direct numerical integration in the Boussinesq approximation. The ground boundary is simulated by images, and fast Fourier Transform techniques are used to evaluate the vorticity stream function. The atmospheric turbulence was simulated by constructing specific realizations at time equal to zero, assuming that Kolmogoroff's law applies, and that the dissipation rate is constant throughout the flow field. The response of a simulated laser Doppler velocimeter is analyzed by simulating the signal return from the flow field as sensed by a simulation of the optical/electronic system.

  8. Augmented Reality Based Doppler Lidar Data Visualization: Promises and Challenges

    NASA Astrophysics Data System (ADS)

    Cherukuru, N. W.; Calhoun, R.

    2016-06-01

    Augmented reality (AR) is a technology in which the enables the user to view virtual content as if it existed in real world. We are exploring the possibility of using this technology to view radial velocities or processed wind vectors from a Doppler wind lidar, thus giving the user an ability to see the wind in a literal sense. This approach could find possible applications in aviation safety, atmospheric data visualization as well as in weather education and public outreach. As a proof of concept, we used the lidar data from a recent field campaign and developed a smartphone application to view the lidar scan in augmented reality. In this paper, we give a brief methodology of this feasibility study, present the challenges and promises of using AR technology in conjunction with Doppler wind lidars.

  9. Tracking driver's heart rate by continuous-wave Doppler radar.

    PubMed

    Kwang Jin Lee; Chanki Park; Boreom Lee

    2016-08-01

    Developing driving safety system with medical assistance devices for preventing accidents has become a major social issue in recent year. These devices have been developed using electrocardiogram (ECG) and photoplethysmogram (PPG) for measuring the heart rate (HR). However, driver should directly contact with the sensor for monitoring the HR. Recently, non-contact system based on continuous-wave Doppler radar has widely studied for monitoring HR. The periodogram by Fast Fourier Transform (FFT) was used for estimating HR. However, if motion artifacts by movement of driver and vehicle vibration contaminate the radar signal, we cannot find spectral peak of HR using FFT. In this paper, we propose a method using multiple signal classification (MUSIC) for estimating HR. We compared MUSIC algorithms with a commonly used FFT method using real experiment data while driving. The results indicate that our proposed method can estimate HR accurately from received radar Doppler signal with motion artifacts.

  10. How to study the Doppler effect with Audacity software

    NASA Astrophysics Data System (ADS)

    Adriano Dias, Marco; Simeão Carvalho, Paulo; Rodrigues Ventura, Daniel

    2016-05-01

    The Doppler effect is one of the recurring themes in college and high school classes. In order to contextualize the topic and engage the students in their own learning process, we propose a simple and easily accessible activity, i.e. the analysis of the videos available on the internet by the students. The sound of the engine of the vehicle passing by the camera is recorded on the video; it is then analyzed with the free software Audacity by measuring the frequency of the sound during approach and recede of the vehicle from the observer. The speed of the vehicle is determined due to the application of Doppler effect equations for acoustic waves.

  11. Atomic Auger Doppler effects upon emission of fast photoelectrons.

    PubMed

    Simon, Marc; Püttner, Ralph; Marchenko, Tatiana; Guillemin, Renaud; Kushawaha, Rajesh K; Journel, Loïc; Goldsztejn, Gildas; Piancastelli, Maria Novella; Ablett, James M; Rueff, Jean-Pascal; Céolin, Denis

    2014-06-06

    Studies of photoemission processes induced by hard X-rays including production of energetic electrons have become feasible due to recent substantial improvement of instrumentation. Novel dynamical phenomena have become possible to investigate in this new regime. Here we show a significant change in Auger emission following 1s photoionization of neon, which we attribute to the recoil of the Ne ion induced by the emission of a fast photoelectron. Because of the preferential motion of the ionized Ne atoms along two opposite directions, an Auger Doppler shift is revealed, which manifests itself as a gradual broadening and doubling of the Auger spectral features. This Auger Doppler effect should be a general phenomenon in high-energy photoemission of both isolated atoms and molecules, which will have to be taken into account in studies of other recoil effects such as vibrational or rotational recoil in molecules, and may also have consequences in measurements in solids.

  12. An integrated microwave Doppler cinemometer for transport applications

    NASA Astrophysics Data System (ADS)

    Descamps, P.; Bekkali, M. El; Vindevoghel, J.

    1991-08-01

    In order to automate the driving of terrestrial vehicles it is necessary to know at any time and with the highest accuracy the values of the speed of the vehicle and of the distance covered by the vehicle; it is also necessary to know the direction of the motion relative to the ground. These values must be measured in the real-time domain and this involves that contactless and very low time-constant sensors must be used. On the other hand, the applications concerned ask for a miniaturization of the whole measurement system. For these reasons, sensors using the Doppler effect in the microwave range are particularly well convenient to these applications. We developed an X band microwave Doppler cinemometer (MDC) with a printed antenna that is built using microstrip technology.

  13. Doppler centroid estimation ambiguity for synthetic aperture radars

    NASA Technical Reports Server (NTRS)

    Chang, C. Y.; Curlander, J. C.

    1989-01-01

    A technique for estimation of the Doppler centroid of an SAR in the presence of large uncertainty in antenna boresight pointing is described. Also investigated is the image degradation resulting from data processing that uses an ambiguous centroid. Two approaches for resolving ambiguities in Doppler centroid estimation (DCE) are presented: the range cross-correlation technique and the multiple-PRF (pulse repetition frequency) technique. Because other design factors control the PRF selection for SAR, a generalized algorithm is derived for PRFs not containing a common divisor. An example using the SIR-C parameters illustrates that this algorithm is capable of resolving the C-band DCE ambiguities for antenna pointing uncertainties of about 2-3 deg.

  14. Using Doppler Shifts of GPS Signals To Measure Angular Speed

    NASA Technical Reports Server (NTRS)

    Campbell, Charles E., Jr.

    2006-01-01

    A method has been proposed for extracting information on the rate of rotation of an aircraft, spacecraft, or other body from differential Doppler shifts of Global Positioning System (GPS) signals received by antennas mounted on the body. In principle, the method should be capable of yielding low-noise estimates of rates of rotation. The method could eliminate the need for gyroscopes to measure rates of rotation. The method is based on the fact that for a given signal of frequency ft transmitted by a given GPS satellite, the differential Doppler shift is attributable to the difference between those components of the instantaneous translational velocities of the antennas that lie along the line of sight from the antennas to the GPS satellite.

  15. Microwave Doppler reflectometer system in the Experimental Advanced Superconducting Tokamak.

    PubMed

    Zhou, C; Liu, A D; Zhang, X H; Hu, J Q; Wang, M Y; Li, H; Lan, T; Xie, J L; Sun, X; Ding, W X; Liu, W D; Yu, C X

    2013-10-01

    A Doppler reflectometer system has recently been installed in the Experimental Advanced Superconducting (EAST) Tokamak. It includes two separated systems, one for Q-band (33-50 GHz) and the other for V-band (50-75 GHz). The optical system consists of a flat mirror and a parabolic mirror which are optimized to improve the spectral resolution. A synthesizer is used as the source and a 20 MHz single band frequency modulator is used to get a differential frequency for heterodyne detection. Ray tracing simulations are used to calculate the scattering location and the perpendicular wave number. In EAST last experimental campaign, the Doppler shifted signals have been obtained and the radial profiles of the perpendicular propagation velocity during L-mode and H-mode are calculated.

  16. Robust estimation of fetal heart rate variability using Doppler ultrasound.

    PubMed

    Fernando, Kumari L; Mathews, V John; Varner, Michael W; Clark, Edward B

    2003-08-01

    This paper presents a new measure of heart rate variability (HRV) that can be estimated using Doppler ultrasound techniques and is robust to variations in the angle of incidence of the ultrasound beam and the measurement noise. This measure employs the multiple signal characterization (MUSIC) algorithm which is a high-resolution method for estimating the frequencies of sinusoidal signals embedded in white noise from short-duration measurements. We show that the product of the square-root of the estimated signal-to-noise ratio (SNR) and the mean-square error of the frequency estimates is independent of the noise level in the signal. Since varying angles of incidence effectively changes the input SNR, this measure of HRV is robust to the input noise as well as the angle of incidence. This paper includes the results of analyzing synthetic and real Doppler ultrasound data that demonstrates the usefulness of the new measure in HRV analysis.

  17. Ultrasonic Doppler measurement of renal artery blood flow

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

  18. Photonic Doppler velocimetry lens array probe incorporating stereo imaging

    DOEpatents

    Malone, Robert M.; Kaufman, Morris I.

    2015-09-01

    A probe including a multiple lens array is disclosed to measure velocity distribution of a moving surface along many lines of sight. Laser light, directed to the moving surface is reflected back from the surface and is Doppler shifted, collected into the array, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to the multiple lens array. Numerous fibers in a fiber array project numerous rays to establish many measurement points at numerous different locations. One or more lens groups may be replaced with imaging lenses so a stereo image of the moving surface can be recorded. Imaging a portion of the surface during initial travel can determine whether the surface is breaking up.

  19. Multipoint photonic doppler velocimetry using optical lens elements

    DOEpatents

    Frogget, Brent Copely; Romero, Vincent Todd

    2014-04-29

    A probe including a fisheye lens is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface and then reflected back from the surface, is Doppler shifted by the moving surface, collected into fisheye lens, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to an index-matching lens and eventually to a fisheye lens. The fiber array flat polished and coupled to the index-matching lens using index-matching gel. Numerous fibers in a fiber array project numerous rays through the fisheye lens which in turn project many measurement points at numerous different locations to establish surface coverage over a hemispherical shape with very little crosstalk.

  20. An ideal blood mimicking fluid for doppler ultrasound phantoms.

    PubMed

    Samavat, H; Evans, J A

    2006-10-01

    In order to investigate the problems of detecting tumours by ultrasound it is very important to have a portable Doppler flow test object to use as a standardising tool. The flow Doppler test objects are intended to mimic the flow in human arteries. To make the test meaningful, the acoustic properties of the main test object components (tissue and blood mimic) should match closely the properties of the corresponding human tissues, while the tube should ideally have little influence. The blood mimic should also represent the haemodynamic properties of blood. An acceptable flow test object has been designed to closely mimic blood flow in arteries. We have evaluated the properties of three blood mimicking fluid: two have been described recently in the literature, the third is a local design. One of these has emerged as being particularly well matched to the necessary characteristics for in-vitro work.

  1. Curvature affects Doppler investigation of vessels: implications for clinical practice.

    PubMed

    Balbis, S; Roatta, S; Guiot, C

    2005-01-01

    In clinical practice, blood velocity estimations from Doppler examination of curved vascular segments are normally different from those of nearby straight segments. The observed "accelerations," sometimes considered as a sort of stochastic disturbances, can actually be related to very specific physical effects due to vessel curvature (i.e., the development of nonaxial velocity [NAV] components) and the spreading of the axial velocity direction in the Doppler sample volume with respect to the insonation axis. The relevant phenomena and their dependence on the radius of curvature of the vessels and on the insonation angle are investigated with a beam-vessel geometry as close as possible to clinical setting, with the simplifying assumptions of steady flow, mild vessel curvature, uniform ultrasonic beam and complete vessel insonation. The insonation angles that minimize the errors are provided on the basis of the study results.

  2. Wind measurements with the High Resolution Doppler Imager (HRDI)

    NASA Technical Reports Server (NTRS)

    Skinner, W. R.; Hays, P. B.; Abreu, V. J.

    1985-01-01

    The Upper Atmosphere Research Satellite (UARS), to be launched in 1989, is to provide a global data set required to understand the mechanisms controlling upper atmosphere structure and processes, as well as the response of the upper atmosphere to natural and human perturbations. The High Resolution Doppler Imager (HRDI) is the primary instrument for measuring the dynamics of the stratosphere and mesosphere. The goal of HRDI is to measure wind velocities in the stratosphere and mesosphere during the day and the mesosphere and thermosphere at night with an accuracy of 5 m/sec. HRDI will determine winds by measuring Doppler shifts of atmosphere absorption and emission features. Line of sight winds will be taken in two directions, thus allowing the wind vector to be formed. The HRDI instrument is overviewed. The basis of the measurement is explained, as is an outline of the instrument. Since neither instrument nor observational techniques is fully mature, only a brief sketch is presented.

  3. Simultaneous fetal magnetocardiography and ultrasound/Doppler imaging.

    PubMed

    Zhao, Hui; Chen, Mingli; Van Veen, Barry D; Strasburger, Janette F; Wakai, Ronald T

    2007-06-01

    The difficulty of utilizing multimodality diagnostic imaging techniques for fetal surveillance remains one of the greatest challenges in providing enhanced prenatal care. In this Letter we demonstrate the feasibility of performing fetal magnetocardiography (fMCG) and ultrasound/Doppler imaging simultaneously, using a multichannel SQUID magnetometer and a portable ultrasound scanner. Despite large magnetic interference from the scanner, the implementation of simple noise reduction procedures and appropriate signal processing techniques yielded fMCG recordings of sufficient quality for assessment of fetal heart rate and rhythm. A variation of reference channel filtering, referred to here as synthetic reference channel filtering, was used to reduce nonstationary low-frequency interference. The combination of fMCG and/or fMEG with ultrasound/Doppler offers new possibilities for assessment of fetal well-being and fetal cardiac function.

  4. Dove prism based rotating dual beam bidirectional Doppler OCT

    PubMed Central

    Blatter, Cedric; Coquoz, Séverine; Grajciar, Branislav; Singh, Amardeep S. G.; Bonesi, Marco; Werkmeister, René M.; Schmetterer, Leopold; Leitgeb, Rainer A.

    2013-01-01

    Traditional Doppler OCT is highly sensitive to motion artifacts due to the dependence on the Doppler angle. This limits its accuracy in clinical practice. To overcome this limitation, we use a bidirectional dual beam technique equipped with a novel rotating scanning scheme employing a Dove prism. The volume is probed from two distinct illumination directions with variable controlled incidence plane, allowing for reconstruction of the true flow velocity at arbitrary vessel orientations. The principle is implemented with Swept Source OCT at 1060nm with 100,000 A-Scans/s. We apply the system to resolve pulsatile retinal absolute blood velocity by performing segment scans around the optic nerve head and circumpapillary scan time series. PMID:23847742

  5. Laser Doppler anemometer studies in unsteady ventricular flows.

    PubMed

    Phillips, W M; Furkay, S S; Pierce, W S

    1979-01-01

    The laser Doppler technique was employed to obtain intraventricular velocity distributions on the basis of in vivo confirmation of previous in vitro flow visualization predictions. The quasi-steady assumption required for quantification of flow visualization results is unsatisfactory in regions of high acceleration and fluctuating velocities are unavailable via such techniques. Mean and fluctuating velocity profiles were obtained in a pneumatically driven prosthetic ventricle with the laser Doppler anemometer and stress levels estimated. The preliminary data presented here illustrates that the technique can be applied to such flows. The measurement and data reduction schemes are applicable to a wide range of simulated cardiovascular flows. The particular application to prosthetic ventricle design should minimize the number of in vivo experiments required to develop a satisfactory blood pump and aid in tailoring pump actuation protocols for minimum thromboembolic complications.

  6. All semiconductor laser Doppler anemometer at 1.55 microm.

    PubMed

    Hansen, René Skov; Pedersen, Christian

    2008-10-27

    We report to our best knowledge the first all semiconductor Laser Doppler Anemometer (LIDAR) for wind speed determination. We will present the design and first experimental results on a focusing coherent cw laser Doppler anemometer for measuring atmospheric wind velocities in the 10 meters to 300 meters distance range. Especially, we will demonstrate that both the output power as well as the demanding coherence properties required from the laser source can be accomplished by an all semiconductor laser. Preliminary tests at a distance of 40 meters indicate a typical signal to noise ratio of 9 dB. This result is obtained at a clear day with an up-date rate of 12 Hz.

  7. Application of FFT analyzed cardiac Doppler signals to fuzzy algorithm.

    PubMed

    Güler, Inan; Hardalaç, Firat; Barişçi, Necaattin

    2002-11-01

    Doppler signals, recorded from the output of tricuspid, mitral, and aorta valves of 60 patients, were transferred to a personal computer via 16-bit sound card. The fast Fourier transform (FFT) method was applied to the recorded signal from each patient. Since FFT method inherently cannot offer a good spectral resolution at highly turbulent blood flows, it sometimes leads to wrong interpretation of cardiac Doppler signals. In order to avoid this problem, firstly six known diseased heart signals such as hypertension, mitral stenosis, mitral failure, tricuspid stenosis, aorta stenosis, aorta insufficiency were introduced to fuzzy algorithm. Then, the unknown heart diseases from 15 patients were applied to the same fuzzy algorithm in order to detect the kinds of diseases. It is observed that the fuzzy algorithm gives true results for detecting the kind of diseases.

  8. A preliminary investigation of bird classification by Doppler radar

    NASA Technical Reports Server (NTRS)

    Martinson, L. W.

    1973-01-01

    A preliminary study of the application of Doppler radar to the classification of birds is reported. The desirability for improvements in bird classification stems primarily from the hazards they present to jet aircraft in flight and in the vicinity of airports. A secondary need exists in the study of bird migration. The wing body and tail motion of a bird in flight reflect signals which, when analyzed properly present a signature of wing beat pattern which is unique for each bird species. Although the results of this investigation did not validate the feasibility of classifying bird species, they do indicate that a more thorough investigation is warranted. Certain gross characteristics such as wing beat rates, multiple bird patterns, and bird maneuverability, were indicated clearly in the results. Large birds with slow wing beat rates appear to be the most optimum subject for further study with the X-band Doppler radar used in this investigation.

  9. Ionospheric S-shaped Doppler fluctuations produced by the tornadoes

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Rao, G. L.; Smith, R. E.

    1974-01-01

    A three-dimensional nine element HF-CW Doppler sounder array has been used to detect ionospheric disturbances which may be due to tornadoes. The typical events chosen in the present study occurred on November 20 and 27, 1973. Both events are apparently associated with tornadoes sighted in the Huntsville, Alabama area. The Doppler records show S-shaped waves rather than the quasi-sinusoidal waves observed in conjunction with and apparently due to thunderstorms. The wave-periods are in the range of 6 to 8 minutes instead of the 3 to 5 minute periods associated with thunderstorms. Dissipation of waves is mostly due to the evanescent effect and they cannot propagate very far from the path of the tornado center. A theory is presented which is in good agreement with the observations.

  10. HF Doppler observations of acoustic waves excited by the earthquake

    NASA Technical Reports Server (NTRS)

    Ichinose, T.; Takagi, K.; Tanaka, T.; Okuzawa, T.; Shibata, T.; Sato, Y.; Nagasawa, C.; Ogawa, T.

    1985-01-01

    Ionospheric disturbances caused by the earthquake of a relatively small and large epicentral distance have been detected by a network of HF-Doppler sounders in central Japan and Kyoto station, respectively. The HF-Doppler data of a small epicentral distance, together with the seismic data, have been used to formulate a mechanism whereby ionospheric disturbances are produced by the Urakawa-Oki earthquake in Japan. Comparison of the dynamic spectra of these data has revealed experimentally that the atmosphere acts as a low-pass filter for upward-propagating acoustic waves. By surveying the earthquakes for which the magnitude M is larger than 6.0, researchers found the ionospheric effect in 16 cases of 82 seismic events. As almost all these effects have occurred in the daytime, it is considered that it may result from the filtering effect of the upward-propagating acoustic waves.

  11. Performance evaluation of a thermal Doppler Michelson interferometer system.

    PubMed

    Mani, Reza; Dobbie, Steven; Scott, Alan; Shepherd, Gordon; Gault, William; Brown, Stephen

    2005-11-20

    The thermal Doppler Michelson interferometer is the primary element of a proposed limb-viewing satellite instrument called SWIFT (Stratospheric Wind Interferometer for Transport studies). SWIFT is intended to measure stratospheric wind velocities in the altitude range of 15-45 km. SWIFT also uses narrowband tandem etalon filters made of germanium to select a line out of the thermal spectrum. The instrument uses the same technique of phase-stepping interferometry employed by the Wind Imaging Interferometer onboard the Upper Atmosphere Research Satellite. A thermal emission line of ozone near 9 microm is used to detect the Doppler shift due to winds. A test bed was set up for this instrument that included the Michelson interferometer and the etalon filters. For the test bed work, we investigate the behavior of individual components and their combination and report the results.

  12. Laser Doppler velocimeter measurements in a turbine stator cascade facility

    NASA Technical Reports Server (NTRS)

    Seasholtz, R. G.

    1974-01-01

    A laser Doppler velocimeter (LDV) developed for mapping the flow velocity downstream from a 32-inch diameter annular cascade of turbine stator vanes in described. The LDV measurements were taken in a plane located approximately 0.5 inch downstream of the trailing edges of the vanes. Two components of the mean velocity (axial and circumferential) were measured. The flow velocities were in the high subsonic range. The LDV optics are of the dual scatter type with off-axis collection of the scattered light. The electronics system is based on the measurement of the time interval corresponding to eight periods of the Doppler signal and has a range of 10 to 80 MHz. The LDV measurements are compared with previous measurements made with a pressure probe.

  13. Laser Doppler velocimeter measurements in a turbine stator cascade facility

    NASA Technical Reports Server (NTRS)

    Seasholtz, R. G.

    1974-01-01

    A laser Doppler velocimeter (LDV) developed for mapping the flow velocity downstream from a 32-inch diameter annular cascade of turbine stator vanes is described. The LDV measurements were taken in a plane located approximately 0.5 inch downstream of the trailing edges of the vanes. Two components of the mean velocity (axial and circumferential) were measured. The flow velocities were in the high subsonic range. The LDV optics are of the dual scatter type with off-axis collection of the scattered light. The electronics system is based on the measurement of the time interval corresponding to eight periods of the Doppler signal and has a range of 10 to 80 MHz. The LDV measurements are compared with previous measurements made with a pressure probe.

  14. An introduction to Doppler effect and fading in mobile communications

    NASA Astrophysics Data System (ADS)

    Depaula, Abdon B.

    1992-12-01

    In this research we present an introductory analysis of a complex aspect of mobile communications: Doppler effect is evaluated in both Ricean and Rayleigh channels. A noncoherent 2-FSK scheme is selected to evaluate the behavior of the system under very strong fading channel conditions. The analysis is conducted for the binary case due to the possibility of developing closed form solutions. Therefore, the approach is simplified avoiding long lasting simulations that may obscure the concepts. The probability of bit error for the 2-FSK case can also be used as an initial bound for a M-FSK scheme. Diversity is evaluated as a means of combating fading and Doppler effects. Error correcting codes, in the form of a convolutional codes, are also used and applied to both effects.

  15. Apollo-Soyuz Doppler-tracking experiment MA-089

    NASA Technical Reports Server (NTRS)

    Weiffenbach, G. C.; Grossi, M. D.; Shores, P. W.

    1976-01-01

    The Doppler tracking experiment was designed to test the feasibility of improved mapping of the earth's gravity field by the low-low satellite-to-satellite tracking method and to observe variations in the electron density of the ionosphere between the two spacecraft. Data were taken between 1:01 and 14:37 GMT on July 24, 1975. Baseline data taken earlier, while the docking module was still attached to the command and service module, indicated that the equipment operated satisfactorily. The ionospheric data contained in the difference between the Doppler signals at the two frequencies are of excellent quality, resulting in valuable satellite-to-satellite observations, never made before, of wave phenomena in the ionosphere. The gravity data were corrupted by an unexpectedly high noise level of as-yet-undetermined origin, with periods greater than 150 seconds, that prevented unambiguous identification of gravity-anomaly signatures.

  16. Normal Doppler velocimetry of renal vasculature in Persian cats.

    PubMed

    Carvalho, Cibele F; Chammas, Maria C

    2011-06-01

    Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m

  17. Laser Doppler velocimetry using a modified computer mouse

    NASA Astrophysics Data System (ADS)

    Zaron, Edward D.

    2016-10-01

    A computer mouse has been modified for use as a low-cost laser Doppler interferometer and used to measure the two-component fluid velocity of a flowing soap film. The mouse sensor contains two vertical cavity surface emitting lasers, photodiodes, and signal processing hardware integrated into a single package, approximately 1 cm2 in size, and interfaces to a host computer via a standard USB port. Using the principle of self-mixing interferometry, whereby laser light re-enters the laser cavity after being scattered from a moving target, the Doppler shift and velocity of scatterers dispersed in the flow are measured. Observations of the boundary layer in a turbulent soap film channel flow demonstrate the capabilities of the sensor.

  18. Normal and anomalous Doppler effects in periodic waveguide cyclotron maser

    SciTech Connect

    Korol, M.; Jerby, E.

    1995-12-31

    A linear analysis of the periodic-waveguide cyclotron (PWC) maser shows that the PWC interaction with fast-waves possesses properties of the known anomalous Doppler resonance interaction if the wave impedance of the resonant spatial harmonic, Z{sub n}, is much smaller than the free space impedance, i.e. if Z{sub n} {much_lt} Z{sub 0}. The feasibility of a fast-wave PWC interaction in a low impedance waveguide is examined theoretically in this paper. A practical scheme of a slotted-waveguide PWC operating in the fundamental harmonic near cutoff is proposed for a future experiment. The possible advantages of the quasi-anomalous Doppler effect in the fast-wave-PWC operating regime are the alleviation of the initial electron rotation and a high-efficiency operation.

  19. Ge's Mobile, Coherent Doppler Lidar Test/Ealuation Facilities

    NASA Technical Reports Server (NTRS)

    Sroga, J. T.; Scott, J. W.; Kiernan, S. C.; Weaver, F. J.; Trotta, J. E.; Petheram, J. C.

    1992-01-01

    The primary objective of this independent research and development (IR and D) program in support of the Laser Atmospheric Wind Sounder (LAWS) program is to develop and evaluate technologies with direct applications to spaceborne laser wind sensing, and to develop system level engineering experience in designing, operating, and modeling a coherent Doppler lidar. GE is developing a mobile, ground based coherent Doppler lidar as an end-to-end system level test facility to evaluate applicable technologies, verify system level performance issues, perform instrument calibration, and validate end-to-end system performance model predictions. Here, the primary focus is on a description of the ground based lidar system and the performance during the initial shakedown operation after system integration.

  20. A novel approach for Doppler blood flow measurement.

    PubMed

    McNamara, D M; Goli, A; Ziarani, A K

    2008-01-01

    A new approach to frequency estimation for the velocity estimation in Doppler ultrasound blood flow analysis is presented. The basis of the approach is an adaptive sinusoid-tracking algorithm which is effective in extracting nonstationary signals from within noise and estimating their time-varying parameters, such as the frequency, over time. The preliminary studies conducted using simulated signals show the potential of this approach in estimating Doppler frequency shifts under noisy conditions. A qualitative comparison with the short-time Fourier transform (STFT) is presented to show the advantages of the proposed technique over the STFT. The proposed approach offers advantages over conventional time-frequency analysis techniques in terms of high time-frequency resolution and high noise immunity.

  1. Theoretical model for Sub-Doppler Cooling with EIT System

    NASA Astrophysics Data System (ADS)

    He, Peiru; Tengdin, Phoebe; Anderson, Dana; Rey, Ana Maria; Holland, Murray

    2016-05-01

    We propose a of sub-Doppler cooling mechanism that takes advantage of the unique spectral features and extreme dispersion generated by the so-called Electromagnetically Induced Transparency (EIT) effect, a destructive quantum interference phenomenon experienced by atoms with Lambda-shaped energy levels when illuminated by two light fields with appropriate frequencies. By detuning the probe lasers slightly from the ``dark resonance'', we observe that atoms can be significantly cooled down by the strong viscous force within the transparency window, while being just slightly heated by the diffusion caused by the small absorption near resonance. In contrast to polarization gradient cooling or EIT sideband cooling, no external magnetic field or external confining potential are required. Using a semi-classical method, analytical expressions, and numerical simulations, we demonstrate that the proposed EIT cooling method can lead to temperatures well below the Doppler limit. This work is supported by NSF and NIST.

  2. Doppler radar fall activity detection using the wavelet transform.

    PubMed

    Su, Bo Yu; Ho, K C; Rantz, Marilyn J; Skubic, Marjorie

    2015-03-01

    We propose in this paper the use of Wavelet transform (WT) to detect human falls using a ceiling mounted Doppler range control radar. The radar senses any motions from falls as well as nonfalls due to the Doppler effect. The WT is very effective in distinguishing the falls from other activities, making it a promising technique for radar fall detection in nonobtrusive inhome elder care applications. The proposed radar fall detector consists of two stages. The prescreen stage uses the coefficients of wavelet decomposition at a given scale to identify the time locations in which fall activities may have occurred. The classification stage extracts the time-frequency content from the wavelet coefficients at many scales to form a feature vector for fall versus nonfall classification. The selection of different wavelet functions is examined to achieve better performance. Experimental results using the data from the laboratory and real inhome environments validate the promising and robust performance of the proposed detector.

  3. [The value of Doppler ultrasound studies in threatened premature labor].

    PubMed

    Jörn, H; Funk, A; Fendel, H

    1993-01-01

    95 patients were investigated using Doppler ultrasound to evaluate its usefulness during the clinical management of patients with preterm labor, preterm rupture of membranes and incompetent cervix. Cases with additional pregnancy complications as preeclampsia or intrauterine growth retardation or infection of the amnion or the birth canal were excluded from our study. We examined the umbilical artery and the uterine arteries. Predicting preterm birth we found a sensitivity of 31.4% and a specificity of 70% for the former and a sensitivity of 34.3% and a specificity of 83.3% for the latter. As a result of our investigation we have to conclude that Doppler ultrasound is not able to predict sufficiently reliable preterm birth to use it in clinical management. Normal uterine blood flow in cases with preterm labor seems to indicate birth at term in a high degree.

  4. Rotational Dove prism scanning dual angle Doppler OCT

    NASA Astrophysics Data System (ADS)

    Blatter, Cedric; Coquoz, Séverine; Grajciar, Branislav; Singh, Amardeep S. G.; Werkmeister, René M.; Schmetterer, Leopold; Leitgeb, Rainer A.

    2013-03-01

    Traditional Doppler OCT is highly sensitive to motion artifacts due to the dependence on the Doppler angle. This limits its reproducibility in clinical practice. To overcome this limitation, we use a bidirectional technique with a novel rotating scanning scheme. The volume is probed simultaneously from two distinct illumination directions with variable controlled orientations, allowing reconstruction of the true flow velocity, independently of the vessel orientation. A Dove prism in the sample arm permits a rotation of the illumination directions that can be synchronized with the standard beam steering device. The principle is implemented with Swept Source OCT at 1060nm with 100,000 A-Scans/s. We apply the system to human retinal absolute blood velocity measurement by performing segment and circumpapillary time series scans around the optic nerve head. We also demonstrate microvasculature imaging by calculation of squared intensity differences between successive tomograms.

  5. Graphical Representation of the Doppler Shift: Classical and Relativistic

    ERIC Educational Resources Information Center

    Rojas, R.; Fuster, G.

    2007-01-01

    The Doppler shift is a frequency change of a repetitive effect, as measured by a receiver, due to the motion of the wave emitter, to the motion of the wave receiver, or both. A demonstration of the effect is provided by the sound of a car's horn that changes from a higher pitch to a lower pitch when a car drives past. Most derivations of the…

  6. Spread-Spectrum Carrier Estimation With Unknown Doppler Shift

    NASA Technical Reports Server (NTRS)

    DeLeon, Phillip L.; Scaife, Bradley J.

    1998-01-01

    We present a method for the frequency estimation of a BPSK modulated, spread-spectrum carrier with unknown Doppler shift. The approach relies on a classic periodogram in conjunction with a spectral matched filter. Simulation results indicate accurate carrier estimation with processing gains near 40. A DSP-based prototype has been implemented for real-time carrier estimation for use in New Mexico State University's proposal for NASA's Demand Assignment Multiple Access service.

  7. Doppler Tomography of the Dwarf Nova IY UMa During Quiescence

    NASA Astrophysics Data System (ADS)

    Rolfe, D. J.; Abbott, T. M. C.; Haswell, C. A.

    Quiescent Doppler tomography of the newly discovered deeply-eclipsing SU UMa system IY UMa reveals properties of the region where the accretion stream from the donor impacts the edge of the disc. A very strong bright spot is produced and the Keplerian disc emission in the impact region is disrupted or obscured. The differing properties of Hα, Hβ and He I emission will allow physical parameters of the converging flow region to be studied.

  8. Laser Doppler flowmetry in diagnoses of chronic tonsillitis

    NASA Astrophysics Data System (ADS)

    Mareew, Gleb O.; Mareew, Oleg V.; Maslyakova, Galina N.; Ivliev, Igor I.; Fedosov, Ivan V.; Lychagov, Vladislav V.; Tuchin, Valery V.

    2005-06-01

    Chronic tonsillitis is one of the most common diseases in ENT all over the world. There are two ways of treatment-surgical tonsillectomy and conservative therapeutically treatment. But still doctors have no possibility to make objective decisions for this painful and tonsil-destructive operation. In this article we try to research how the degree of sclerosis in tonsillar tissue affects the blood flow in tonsils, by using laser Doppler flowmetry.

  9. Laser Doppler spectrometer method of particle sizing. [for air pollution

    NASA Technical Reports Server (NTRS)

    Weber, F. N.

    1976-01-01

    A spectrometer for the detection of airborne particulate pollution in the submicron size range is described. In this device, airborne particles are accelerated through a supersonic nozzle, with different sizes achieving different velocities in the gas flow. Information about the velocities of the accelerated particles is obtained with a laser-heterodyne optical system through the Doppler shift of light scattered from the particles. Detection is accomplished by means of a photomultiplier. Nozzle design and signal processing techniques are also discussed.

  10. Simultaneous two-wavelength Doppler phase-shifting digital holography.

    PubMed

    Barada, Daisuke; Kiire, Tomohiro; Sugisaka, Jun-ichiro; Kawata, Shigeo; Yatagai, Toyohiko

    2011-12-01

    This paper presents a method based on the use of an image sensor for obtaining the complex amplitudes of beams diffracted from an object at two different wavelengths. The complex amplitude for each wavelength is extracted by the Doppler phase-shifting method. The principle underlying the proposed method is experimentally verified by using the method with two lasers having different wavelengths to measure the surface shape of a concave mirror.

  11. Teaching Doppler Effect with a passing noise source

    NASA Astrophysics Data System (ADS)

    Costa, Ivan F.; Mocellin, Alexandra

    2010-07-01

    The noise pitch variation of a passing noise source allows a low cost experimental approach to calculate speed and, for the first time, distance. We adjusted the recorded noise pitch variation to the Doppler shift equation for sound. We did this by taking into account the frequency delay due to the sound source displacement and performing a Fast Fourier Transform (FFT) of the noise signal using free software. This experimental method was successfully applied to aircraft and automobiles.

  12. Comparison between digital Doppler filtering processes applied to radar signals

    NASA Astrophysics Data System (ADS)

    Desodt, G.

    1983-10-01

    Two families of Doppler processes based on FFT and FIR filters, respectively, are compared in terms of hardware complexity and performance. It is shown that FIR filter banks are characterized by better performance than FFT filter banks. For the same number of pulses, the FIR processor permits a better clutter rejection and greater bandwidth than the FFT one. Also, an FIR-based bank has a much simpler and more adaptable architecture than an FFT-based bank.

  13. Three-dimensional Doppler anemometer using a holographic optical element.

    PubMed

    Schneider, F; Windein, W

    1988-11-01

    A new simple 3-D laser Doppler system has been developed for simultaneous measurement of the instantaneous velocity vector of a scattering particle. The system is based on the reference beam method. It uses a hologram to generate the reference beams. Only one laser operating in single mode is required as the light source. The system has been tested by measuring all the components of the Reynolds stress tensor in a round cold air jet. The results are presented.

  14. Ultrasonic Doppler measurement of renal artery blood flow

    NASA Technical Reports Server (NTRS)

    Freund, W. R.; Meindl, J. D.

    1975-01-01

    An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

  15. Phase-referenced Doppler optical coherence tomography in scattering media.

    PubMed

    Pedersen, Cameron J; Yazdanfar, Siavash; Westphal, Volker; Rollins, Andrew M

    2005-08-15

    We present a fiber-based, low-coherence interferometer that significantly reduces phase noise by incorporating a second, narrowband, continuous-wave light source as a phase reference. By incorporating this interferometer into a Doppler OCT system, we demonstrate significant velocity noise reduction in reflective and scattering samples using processing techniques amenable to real-time implementation. We also demonstrate 90% suppression of velocity noise in a flow phantom.

  16. A Compact Programmable Laser Doppler Velocimeter for Marine Applications

    DTIC Science & Technology

    1990-11-01

    signal which was processed. 11 RON0101 To demonstrate the three beam laser Doppler velocimeter in water, a Plexiglass test chamber was constructed. A pump ...stationary particle ( pump off). The Fourier transform of this signal is shown on Figure 8 and demonstrates that for the no flow case the measured...required to obtain adequate signal resolution. To demonstrate the three beam LDV in water, a Plexiglass test chamber was constructed. A pump flowed

  17. Evaluation of the MV (CAPON) Coherent Doppler Lidar Velocity Estimator

    NASA Technical Reports Server (NTRS)

    Lottman, B.; Frehlich, R.

    1997-01-01

    The performance of the CAPON velocity estimator for coherent Doppler lidar is determined for typical space-based and ground-based parameter regimes. Optimal input parameters for the algorithm were determined for each regime. For weak signals, performance is described by the standard deviation of the good estimates and the fraction of outliers. For strong signals, the fraction of outliers is zero. Numerical effort was also determined.

  18. Harmonic Motion Microwave Doppler Imaging method for breast tumor detection.

    PubMed

    Top, Can Barıs; Tafreshi, Azadeh Kamali; Gençer, Nevzat G

    2014-01-01

    Harmonic Motion Microwave Doppler Imaging (HMMDI) method is recently proposed as a non-invasive hybrid breast imaging technique for tumor detection. The acquired data depend on acoustic, elastic and electromagnetic properties of the tissue. The potential of the method is analyzed with simulation studies and phantom experiments. In this paper, the results of these studies are summarized. It is shown that HMMDI method has a potential to detect malignancies inside fibro-glandular tissue.

  19. Adaptive cancellation of harmonic interferences in transcranial Doppler signal

    NASA Astrophysics Data System (ADS)

    Zabolotny, Wojciech M.; Karlowicz, Pawel; Jurkiewicz, Jerzy

    2004-07-01

    This paper presents a method of improving the Transcranial Doppler (TCD) signal by removing harmonic interferences. Such interferences, originating from medical equipment using the high power HF signals are common in a clinical environment, especially in the neighborhood of the operating theater. The Adaptive Interference Canceler based on the NLMS FIR filter has been used. The reference signal was obtained by delaying of the original TCD signal. The presented method allows significant improvement of a seriously disturbed TCD signal.

  20. Identification and Minimization of Errors in Doppler Global Velocimetry Measurements

    NASA Technical Reports Server (NTRS)

    Meyers, James F.; Lee, Joseph W.

    2000-01-01

    A systematic laboratory investigation was conducted to identify potential measurement error sources in Doppler Global Velocimetry technology. Once identified, methods were developed to eliminate or at least minimize the effects of these errors. The areas considered included the Iodine vapor cell, optical alignment, scattered light characteristics, noise sources, and the laser. Upon completion the demonstrated measurement uncertainty was reduced to 0.5 m/sec.

  1. Wind Measurements with High Energy 2 Micron Coherent Doppler Lidar

    NASA Technical Reports Server (NTRS)

    Barnes, Bruce W.; Koch, Grady J.; Petros, Mulugeta; Beyon, Jeffrey Y.; Amzajerdian, Farzin; Yu, Ji-Rong; Kavaya, Michael J.; Singh, Upendra N.

    2004-01-01

    A coherent Doppler lidar based on an injection seeded Ho:Tm:YLF pulsed laser was developed for wind measurements. A transmitted pulse energy over 75 mJ at 5 Hz repetition rate has been demonstrated. Designs are presented on the laser, injection seeding, receiver, and signal processing subsystems. Sample data of atmospheric measurements are presented including a wind profile extending from the atmospheric boundary layer (ABL) to the free troposphere.

  2. A Fisheye Lens as a Photonic Doppler Velocimetry Probe

    SciTech Connect

    Frogget, B. C.

    2012-08-16

    These presentation visuals report an instrument that, by use of a fish-eye lens, generates a beat signal using fiber mixing of unshifted light with Doppler-shifted light and measures the beat frequency. Ray trace diagrams are shown to illustrate advantages and disadvantages. The authors find their instrument has a long tracking distance, and large angle coverage. Index matching eases assembly, reduces return loss and flattens the field.

  3. Micro-Doppler Radar Signatures for Itelligent Target Recognition

    DTIC Science & Technology

    2004-09-01

    es. En tant qu’outil d’identification et de reconnaissance, l’effet m-D semble prometteur pour les syst~mes op ~ rationnels susceptibles d’am~liorer...Defence Research and Recherche et developpement Development Canada pour la defense Canada DEFENCE DE7 DEFENS . Micro-Doppler radar signatures for... recherche permettant d’atteindre les objectifs techniques d6sir6s. ii DRDC Ottawa TM 2004-170 Executive summary Mechanical vibrations or rotations of

  4. Robust population transfer in atomic beams induced by Doppler shifts

    NASA Astrophysics Data System (ADS)

    Unanyan, R. G.

    2016-10-01

    The influence of photon momentum recoil on adiabatic population transfer in an atomic three-level lambda system is studied. It is shown that the Doppler frequency shifts, due to atomic motion, can play an important role in adiabatic population transfer processes of atomic internal states by a pair of laser fields. For the limiting case of slow atoms (Doppler shift much smaller than the photon recoil energy), the atoms occupy the same target state regardless of the order of switching of laser fields, while for the case of fast atoms interacting with the intuitive sequence of pulses, the target state is the intermediate atomic state. Furthermore, it is shown that this novel technique for adiabatic population transfer is related to a level crossing in the bright-intermediate state basis (rather than in the original atomic basis). It is shown that these processes are robust with respect to parameter fluctuations, such as the laser pulse area and the relative spatial offset (delay) of the laser beams. The obtained results can be used for the control of temporal evolution of atomic populations in cold atomic beams by externally adjustable Doppler shifts.

  5. Doppler effect in opposite propagating modes of cavity

    NASA Astrophysics Data System (ADS)

    Enaki, Nicolae; Bazgan, Sergiu

    2016-12-01

    It is proposed a new approach in the estimation of quantum fluctuations of the electromagnetic field and Doppler effect using a model formed from two quantum modes of the cavity which propagate in opposite direction. The Doppler effect plays a significant role in the model in which an atom flies through the nodes and anti-nodes of the standing wave. It is shown that if the vacuum Rabi frequency achieves the value of Doppler shift kv, where k is the wave vector and v represents the atomic velocity, then the collective interactive and non-interactive modes of the resonator become connected. The interaction process looks like in the case of two coupled cavities in one of which is placed an atom. The comparison between the proposed approach and existing time dependent coupling model is given. In our model, it is obtained the non-zero value of quantum fluctuations in the nodes of the standing wave during the time in which atom flies through the cavity.

  6. Active Region Moss: Doppler Shifts from Hinode/EIS Observations

    NASA Technical Reports Server (NTRS)

    Tripathi, Durgesh; Mason, Helen E.; Klimchuk, James A.

    2012-01-01

    Studying the Doppler shifts and the temperature dependence of Doppler shifts in moss regions can help us understand the heating processes in the core of the active regions. In this paper we have used an active region observation recorded by the Extreme-ultraviolet Imaging Spectrometer (EIS) onboard Hinode on 12-Dec- 2007 to measure the Doppler shifts in the moss regions. We have distinguished the moss regions from the rest of the active region by defining a low density cut-off as derived by Tripathi et al. (2010). We have carried out a very careful analysis of the EIS wavelength calibration based on the method described in Young, O Dwyer and Mason (2012). For spectral lines having maximum sensitivity between log T = 5.85 and log T = 6.25 K, we find that the velocity distribution peaks at around 0 km/s with an estimated error of 4 km/s. The width of the distribution decreases with temperature. The mean of the distribution shows a blue shift which increases with increasing temperature and the distribution also shows asymmetries towards blue-shift. Comparing these results with observables predicted from different coronal heating models, we find that these results are consistent with both steady and impulsive heating scenarios. Further observational constraints are needed to distinguish between these two heating scenarios.

  7. Doppler findings in chronic ectopic pregnancy: case report.

    PubMed

    Abramov, Y; Nadjari, M; Shushan, A; Prus, D; Anteby, S O

    1997-05-01

    Chronic ectopic pregnancy is an uncommon form of tubal pregnancy manifested as a pelvic mass with minimal symptoms and a low or absent titer of human chorionic gonadotropin. For this reason, most of the reported cases have been diagnosed only after explorative laparotomy. The value of Doppler ultrasonography for preoperative diagnosis of this entity has not yet been established. We report on a 36-year-old patient who was admitted for intermittent right lower quadrant abdominal pain of 3 months' duration, and a right adnexal mass found on pelvic examination. On Doppler ultrasonography, a right complex adnexal mass was demonstrated, characterized by extensive external vascularization, aberrant vessels and arteriovenous shunting, but with no internal blood flow. Explorative laparotomy revealed a right tubal mass adherent to the omentum, and covered by numerous enlarged and tortuous blood vessels originating in the omentum. Pathological examination of the mass revealed a chronic ectopic pregnancy. The possible contribution of Doppler-specific characteristics for the diagnosis of chronic ectopic pregnancy is described and discussed.

  8. Development of Point Doppler Velocimetry for Flow Field Investigations

    NASA Technical Reports Server (NTRS)

    Cavone, Angelo A.; Meyers, James F.; Lee, Joseph W.

    2006-01-01

    A Point Doppler Velocimeter (pDv) has been developed using a vapor-limited iodine cell as the sensing medium. The iodine cell is utilized to directly measure the Doppler shift frequency of laser light scattered from submicron particles suspended within a fluid flow. The measured Doppler shift can then be used to compute the velocity of the particles, and hence the fluid. Since this approach does not require resolution of scattered light from individual particles, the potential exists to obtain temporally continuous signals that could be uniformly sampled in the manner as a hot wire anemometer. This leads to the possibility of obtaining flow turbulence power spectra without the limitations of fringe-type laser velocimetry. The development program consisted of a methodical investigation of the technology coupled with the solution of practical engineering problems to produce a usable measurement system. The paper outlines this development along with the evaluation of the resulting system as compared to primary standards and other measurement technologies.

  9. Reducing Spaceborne-Doppler-Radar Rainfall-Velocity Error

    NASA Technical Reports Server (NTRS)

    Tanelli, Simone; Im, Eastwood; Durden, Stephen L.

    2008-01-01

    A combined frequency-time (CFT) spectral moment estimation technique has been devised for calculating rainfall velocity from measurement data acquired by a nadir-looking spaceborne Doppler weather radar system. Prior spectral moment estimation techniques used for this purpose are based partly on the assumption that the radar resolution volume is uniformly filled with rainfall. The assumption is unrealistic in general but introduces negligible error in application to airborne radar systems. However, for spaceborne systems, the combination of this assumption and inhomogeneities in rainfall [denoted non-uniform beam filling (NUBF)] can result in velocity measurement errors of several meters per second. The present CFT spectral moment estimation technique includes coherent processing of a series of Doppler spectra generated in a standard manner from data over measurement volumes that are partially overlapping in the along-track direction. Performance simulation of this technique using high-resolution data from an airborne rain-mapping radar shows that a spaceborne Ku-band Doppler radar operating at signal-to-noise ratios greater than 10 dB can achieve root-mean-square accuracy between 0.5 and 0.6 m/s in vertical-velocity estimates.

  10. Micro-Doppler frequency comb generation by rotating wire scatterers

    NASA Astrophysics Data System (ADS)

    Kozlov, V.; Filonov, D.; Yankelevich, Y.; Ginzburg, P.

    2017-03-01

    Electromagnetic scattering in accelerating reference frames inspires a variety of phenomena, requiring employment of general relativity for their description. While the 'quasi-stationary field' analysis could be applied to slowly-accelerating bodies as a first-order approximation, the scattering problem remains fundamentally nonlinear in boundary conditions, giving rise to multiple frequency generation (micro-Doppler shifts). Here a frequency comb, generated by an axially rotating subwavelength (cm-range) wires is analyzed theoretically and observed experimentally by illuminating the system with a 2 GHz carrier wave. Highly accurate 'lock in' detection scheme enables factorization of the carrier and observation of multiple peaks in a comb. The Hallen integral equation is employed for deriving the currents induced on the scatterer and a set of coordinate transformations, connecting laboratory and rotating frames, is applied in order to make analytical predictions of the spectral positions and amplitudes of the frequency comb peaks. Numeric simulations of the theoretic framework reveal the dependence of the micro-Doppler peaks on the wire's length and its axis of rotation. Unique spectral signature of micro-Doppler shifts could enable resolving internal structures of scatterers and mapping their accelerations in space, which is valuable for a variety of applications spanning from targets identification to stellar radiometry.

  11. New signal analysis methods for laser doppler flowmetric recordings

    NASA Astrophysics Data System (ADS)

    ǎgǎnescu, G. E., Dr; Todea, Carmen

    2014-01-01

    The laser Doppler flowmetry devices give a series of information like the blood flux and some statistical parameters, automatically estimated. There are also new important attempts based on the Fourier transform of the flow flux signal which gather more information from the laser Doppler flowmetry. The amplitude spectra estimated in these articles, exhibit a series of peaks corresponding to the cardiac variation of the blood flow and noise components of the flow flux signals, dependent on the state of the tooth. The aim of our investigations is to introduce new signal processing methods, based on wavelet continuous tranform, which express in a more sensitive manner the modifications of the flow flux signal with the state of the tooth, and to introduce new quantitative parameters, defined in a previous paper. These parameters express, in a more sensitive manner the modifications of the pulp flow flux signal in relation with the pulp tooth healt, and to introduce new quantitative parameters, defined in a previous paper. These parameters express, in a sensitive way the changes of the blood flux. For practical investigations we used a series of signals recorded with the aid of a Laser Doppler Blood Flow Monitoring device (Moor Instruments) and processed with the computer.

  12. Lab Demonstration of the Hybrid Doppler Wind Lidar (HDWL) Transceiver

    NASA Technical Reports Server (NTRS)

    Marx, Catherine T.; Gentry, Bruce; Jordan, Patrick; Dogoda, Peter; Faust, Ed; Kavaya, Michael

    2013-01-01

    The recommended design approach for the 3D Tropospheric Winds mission is a hybrid Doppler lidar which combines the best elements of both a coherent aerosol Doppler lidar operating at 2 microns and a direct detection molecular Doppler lidar operating at 0.355 microns. In support of the mission, we built a novel, compact, light-weighted multi-field of view transceiver where multiple telescopes are used to cover the required four fields of view. A small mechanism sequentially selects both the "transmit" and "receive" fields of view. The four fields are combined to stimulate both the 0.355 micron receiver and the 2 micron receiver. This version is scaled (0.2 m diameter aperture) from the space-based version but still demonstrates the feasibility of the hybrid approach. The primary mirrors were conventionally light-weighted and coated with dielectric, high reflectivity coatings with high laser damage thresholds at both 2 microns and 0.355 microns. The mechanical structure and mounts were fabricated from composites to achieve dimensional stability while significantly reducing the mass. In the laboratory, we demonstrated the system level functionality at 0.355 microns and at 2 microns, raising the Technology Readiness Level (TRL) from 2 to 4.

  13. Lab Demonstration of the Hybrid Doppler Wind Lidar (HDWL) Transceiver

    NASA Technical Reports Server (NTRS)

    Marx, Catherine T.; Gentry, Bruce; Jordan, Patrick; Dogoda, Peter; Faust, Ed; Kavaya, Michael

    2013-01-01

    The recommended design approach for the 3D Tropospheric Winds mission is a hybrid Doppler lidar which combines the best elements of both a coherent aerosol Doppler lidar operating at 2 micron and a direct detection molecular Doppler lidar operating at 0.355 micron. In support of the mission, we built a novel, compact, light-weighted multi-field of view transceiver where multiple telescopes are used to cover the required four fields of view. A small mechanism sequentially selects both the "transmit" and "receive" fields of view. The four fields are combined to stimulate both the 0.355 micron receiver and the 2 micron receiver. This version is scaled (0.2 micron diameter aperture) from the space-based version but still demonstrates the feasibility of the hybrid approach. The primary mirrors were conventionally light-weighted and coated with dielectric, high reflectivity coatings with high laser damage thresholds at both 2 micron and 0.355 micron. The mechanical structure and mounts were fabricated from composites to achieve dimensional stability while significantly reducing the mass. In the laboratory, we demonstrated the system level functionality at 0.355 micron and at 2 micron raising the Technology Readiness Level (TRL) from 2 to 4.

  14. [Doppler echocardiographic diagnosis and evaluation of tricuspid regurgitation].

    PubMed

    Blanchard, D; Diébold, B; Guermonprez, J L; Chitour, Z; Née, M; Péronneau, P; Forman, J; Maurice, P

    1982-12-01

    The reliability of pulsed Doppler echocardiography in the diagnosis and quantification of tricuspid regurgitation was assessed by analysis of blood flow in the inferior vena cava in 28 patients. The inferior vena caval flow was sampled in the retrohepatic portion of the vessel from the subxiphoid region. Recordings from 10 normal patients were used to define criteria of normality. This was characterised by two anterograde components (one systolic and one diastolic); atrial contraction gave rise to an end diastolic retrograde component. In tricuspid incompetence, retrograde systolic blood flow was recorded. A Doppler index was calculated from the ratio of the maximal amplitude of systolic reflux to the maximal amplitude of anterograde diastolic flow. In the absence of tricuspid regurgitation, this index approximated 0. The average of this ratio over 10 consecutive beats was compared with the semi quantitative assessment of tricuspid regurgitation from selective right ventricular angiography. There were no false positive results, specificity was, therefore, 100 p. 100. Six minimal regurgitations were not detected: sensitivity was therefore 74 p. 100. All moderate and severe regurgitations were detected, and the sensitivity for these cases was 100 p. 100. There was a close correlation (R = 0,89, p less than 0,01) between the Doppler index and the degree of regurgitation assessed by selective right ventricular angiography.

  15. Thermal tests for laser Doppler perfusion measurements in Raynaud's syndrome

    NASA Astrophysics Data System (ADS)

    Kacprzak, Michal; Skora, A.; Obidzinska, J.; Zbiec, A.; Maniewski, Roman; Staszkiewicz, W.

    2004-07-01

    The laser Doppler method offers a non-invasive, real time technique for monitoring of blood perfusion in microcirculation. In practical measurements the perfusion index is given only in relative values. Thus, accurate and reproducible results can be only obtained when using a well controlled stimulation test. The aim of this study was evaluation of the thermal stimulation test, which is frequently used to investigate microcirculation in patients with Raynaud's syndrome. Three types of thermal tests, in which air or water with temperature in range 5°C - 40°C were used. Ten normal volunteers and fifteen patients with clinical symptoms of the primary Raynaud's syndrome were enrolled in this study. To estimate skin microcirculation changes during the thermal test, the multichannel laser Doppler system and laser Doppler scanner were used. The obtained results were analyzed from the point of view of the efficiency of these methods and the thermal provocative tests in differentiation of normal subjects and patient with Raynaud's syndrome.

  16. Adaptive clutter rejection for ultrasound color Doppler imaging

    NASA Astrophysics Data System (ADS)

    Yoo, Yang Mo; Managuli, Ravi; Kim, Yongmin

    2005-04-01

    We have developed a new adaptive clutter rejection technique where an optimum clutter filter is dynamically selected according to the varying clutter characteristics in ultrasound color Doppler imaging. The selection criteria have been established based on the underlying clutter characteristics (i.e., the maximum instantaneous clutter velocity and the clutter power) and the properties of various candidate clutter filters (e.g., projection-initialized infinite impulse response and polynomial regression). We obtained an average improvement of 3.97 dB and 3.27 dB in flow signal-to-clutter-ratio (SCR) compared to the conventional and down-mixing methods, respectively. These preliminary results indicate that the proposed adaptive clutter rejection method could improve the sensitivity and accuracy in flow velocity estimation for ultrasound color Doppler imaging. For a 192 x 256 color Doppler image with an ensemble size of 10, the proposed method takes only 57.2 ms, which is less than the acquisition time. Thus, the proposed method could be implemented in modern ultrasound systems, while providing improved clutter rejection and more accurate velocity estimation in real time.

  17. Doppler shifts in a tornado in the solar corona

    NASA Astrophysics Data System (ADS)

    Schmieder, B.; Mein, P.; Mein, N.; Levens, P. J.; Labrosse, N.; Ofman, L.

    2017-01-01

    Context. High resolution movies in 193 Å from the Atmospheric Imaging Assembly (AIA) on the Solar Dynamic Observatory (SDO) show apparent rotation in the leg of a prominence observed during a coordinated campaign. Such structures are commonly referred to as tornadoes. Time-distance intensity diagrams of the AIA data show the existence of oscillations suggesting that the structure is rotating. Aims: The aim of this paper is to understand if the cool plasma at chromospheric temperatures inside the tornado is rotating around its central axis. Methods: The tornado was also observed in Hα with a cadence of 30 s by the MSDP spectrograph, operating at the Solar Tower in Meudon. The MSDP provides sequences of simultaneous spectra in a 2D field of view from which a cube of Doppler velocity maps is retrieved. Results: The Hα Doppler maps show a pattern with alternatively blueshifted and redshifted areas of 5 to 10'' wide. Over time the blueshifted areas become redshifted and vice versa, with a quasi-periodicity of 40 to 60 min. Weaker amplitude oscillations with periods of 4 to 6 min are superimposed onto these large period oscillations. Conclusions: The Doppler pattern observed in Hα cannot be interpreted as rotation of the cool plasma inside the tornado. The Hα velocity observations give strong constraints on the possible interpretations of the AIA tornado.

  18. In vivo feasibility of endovascular Doppler optical coherence tomography

    PubMed Central

    Sun, Cuiru; Nolte, Felix; Cheng, Kyle H. Y.; Vuong, Barry; Lee, Kenneth K. C.; Standish, Beau A.; Courtney, Brian; Marotta, Thomas R.; Mariampillai, Adrian; Yang, Victor X. D.

    2012-01-01

    Feasibility of detecting intravascular flow using a catheter based endovascular optical coherence tomography (OCT) system is demonstrated in a porcine carotid model in vivo. The effects of A-line density, radial distance, signal-to-noise ratio, non-uniform rotational distortion (NURD), phase stability of the swept wavelength laser and interferometer system on Doppler shift detection limit were investigated in stationary and flow phantoms. Techniques for NURD induced phase shift artifact removal were developed by tracking the catheter sheath. Detection of high flow velocity (~51 cm/s) present in the porcine carotid artery was obtained by phase unwrapping techniques and compared to numerical simulation, taking into consideration flow profile distortion by the eccentrically positioned imaging catheter. Using diluted blood in saline mixture as clearing agent, simultaneous Doppler OCT imaging of intravascular flow and structural OCT imaging of the carotid artery wall was feasible. To our knowledge, this is the first in vivo demonstration of Doppler imaging and absolute measurement of intravascular flow using a rotating fiber catheter in carotid artery. PMID:23082299

  19. Sevoflurane Used for Color Doppler Ultrasound Examination in Children.

    PubMed

    Fan, Conghai; Zhang, Fengchao; Huang, Xiaomei; Wen, Cheng; Shan, Chengjing

    2015-05-01

    The objective of this study is to investigate the feasibility of sevoflurane inhalation in pediatric color doppler ultrasound examination. In this study, 30 cases of children under 1 year were selected. They were all I or II levels according to American Society of Anesthesiology. Children with severe cyanotic congenital heart disease or severe pneumonia were excluded. All the children received anesthesia with sevoflurane. The University of Michigan Sedation Scale was assessed and bispectral index (BIS) was recorded before induction (T0), after induction (T1), when maintaining (T2), and when waking-up (T3). Blood pressure and heart rate were monitored during the color doppler ultrasound examination, the time to receive sedation examination and anesthesia recovery time were also recorded. (1) Score for UMSS was zero at T0 and 3 at T1; (2) BIS value was 93.18 ± 2.94 at T0 and decreased to 87.6 ± 3.9 at T1; (3) Blood pressure or heart rate did not decline obviously; (4) The time to receive sedation examination was 46.4 ± 13.1 s and anesthesia recovery time was 7.8 ± 5.3 min. In conclusion, sevoflurane can be used in pediatric color doppler ultrasound examination safely and effectively.

  20. The role of Doppler ultrasound in rheumatic diseases.

    PubMed

    Porta, Francesco; Radunovic, Goran; Vlad, Violeta; Micu, Mihaela C; Nestorova, Rodina; Petranova, Tzvetanka; Iagnocco, Annamaria

    2012-06-01

    The use of Doppler techniques, including power, colour and spectral Doppler, has greatly increased in rheumatology in recent years. This is due to the ability of Doppler US (DUS) to detect pathological vascularization within joints and periarticular soft tissues, thereby demonstrating the presence of active inflammation, which has been reported to be correlated with the local neo-angiogenesis. In synovitis, DUS showed a high correlation with histological and MRI findings, thus it is considered a valid tool to detect pathological synovial vascularization. Moreover, it is more sensitive than clinical examination in detecting active joint inflammation and in the evaluation of response to treatment. In addition, DUS may be considered as a reference imaging modality in the assessment of enthesitis, MRI being not sensitive and histology not feasible. Moreover, it has been demonstrated to be able to detect changes in asymptomatic enthesis. In conclusion, DUS is a useful and sensitive tool in the evaluation and monitoring of active inflammation. Its widespread use in clinical rheumatological practice is recommended. The aim of this article is to review the current literature about the role of DUS in rheumatic diseases, analysing its validity, reliability and feasibility.

  1. Novel measure for the calibration of laser Doppler flowmetry devices

    NASA Astrophysics Data System (ADS)

    Dunaev, Andrey V.; Zherebtsov, Evgeny A.; Rogatkin, Dmitrii A.; Stewart, Neil A.; Sokolovski, Sergei G.; Rafailov, Edik U.

    2014-03-01

    The metrological basis for optical non-invasive diagnostic devices is an unresolved issue. A major challenge for laser Doppler flowmetry (LDF) is the need to compare the outputs from individual devices and various manufacturers to identify variations useful in clinical diagnostics. The most common methods for instrument calibration are simulants or phantoms composed of colloids of light-scattering particles which simulate the motion of red blood cells based on Brownian motion. However, such systems have limited accuracy or stability and cannot calibrate for the known rhythmic components of perfusion (0.0095-1.6 Hz). To solve this problem, we propose the design of a novel technique based on the simulation of moving particles using an electromechanical transducer, in which a precision piezoelectric actuator is used (e.g., P-602.8SL with maximum movement less than 1 mm). In this system, Doppler shift is generated in the layered structure of different solid materials with different optical light diffusing properties. This comprises a fixed, light transparent upper plane-parallel plate and an oscillating fluoroplastic (PTFE) disk. Preliminary studies on this experimental setup using the LDF-channel of a "LAKK-M" system demonstrated the detection of the linear portion (0-10 Hz with a maximum signal corresponding to Doppler shift of about 20 kHz) of the LDF-signal from the oscillating frequency of the moving layer. The results suggest the possibility of applying this technique for the calibration of LDF devices.

  2. Doppler Spectra and Estimated Windspeed of a Violent Tornado.

    NASA Astrophysics Data System (ADS)

    Zrni, Dusan; Burgess, Donald W.; Hennington, Larry

    1985-10-01

    Presented in this Paper are Doppler spectra of a very large tornado that occurred on 22 May 1981 near Binger, Oklahoma. Tracking of the tornado was accomplished with the help of a novel `polar spectra display.' Bimodal tornado spectral signatures (TSS) were observed in about 40 scans. Direct measurements of maximum velocities from spectral skirts yielded a maximum tangential speed of 80 m s1 (90 m s1 relative to ground). A diameter of 1 km at 200 m above ground was deduced from a simplified model. Radial centrifuging of radar targets was estimated to be about 20 m s1. With simple assumptions for radar target sizes and summation of forces, a beamwidth average convergence value of about 2.5 × 102 s1 was calculated for the tornado boundary layer.Tornado damage to trees and structures was subjectively rated on the Fujita damage scale. The windspeed range associated with the damage scale agreed well with the Doppler-estimated maximum windspeed when the tornado was large (1 km diameter). However, as the tornado diameter decreased, the Doppler-derived windspeed considerably underestimated that associated with the damage scale.

  3. Turbulence as observed by concurrent measurements made at NSSL using weather radar, Doppler radar, Doppler lidar and aircraft

    NASA Technical Reports Server (NTRS)

    Lee, Jean T.

    1987-01-01

    As air traffic increases and aircraft capability increases in range and operating altitude, the exposure to weather hazards increases. Turbulence and wind shears are two of the most important of these hazards that must be taken into account if safe flight operations are to be accomplished. Beginning in the early 1960's, Project Rough Rider began thunderstorm investigations. Past and present efforts at the National Severe Storm Laboratory (NSSL) to measure these flight safety hazards and to describe the use of Doppler radar to detect and qualify these hazards are summarized. In particular, the evolution of the Doppler-measured radial velocity spectrum width and its applicability to the problem of safe flight is presented.

  4. Hurricane properties by principal component analysis of Doppler radar data

    NASA Astrophysics Data System (ADS)

    Harasti, Paul Robert

    A novel approach based on Principal Component Analysis (PCA) of Doppler radar data establishes hurricane properties such as the positions of the circulation centre and wind maxima. The method was developed in conjunction with a new Doppler radar wind model for both mature and weak hurricanes. The tangential wind (Vt) is modeled according to Vtζx = constant, where ζ is the radius, and x is an exponent. The maximum Vt occurs at the Radius of Maximum Wind (RMW). For the mature (weak) hurricane case, x = 1 ( x < 1) within the RMW, and x = 0.5 ( x = 0) beyond the RMW. The radial wind is modeled in a similar fashion in the radial direction with up to two transition radii but it is also varied linearly in the vertical direction. This is the first Doppler radar wind model to account for the vertical variations in the radial wind. The new method employs an S2-mode PCA on the Doppler velocity data taken from a single PPI scan and arranged sequentially in a matrix according to their azimuth and range coordinates. The first two eigenvectors of both the range and azimuth eigenspaces represent over 95% of the total variance in the modeled data; one eigenvector from each pair is analyzed separately to estimate particular hurricane properties. These include the bearing and range to the hurricane's circulation centre, the RMW, and the transition radii of the radial wind. Model results suggest that greater accuracy is achievable and fewer restrictions apply in comparison to other methods. The PCA method was tested on the Doppler velocity data of Hurricane Erin (1995) and Typhoon Alex (1987). In both cases, the similarity of the eigenvectors to their theoretical counterparts was striking even in the presence of significant missing data. Results from Hurricane Erin were in agreement with concurrent aircraft observations of the wind centre corrected for the storm motion. Such information was not available for Typhoon Alex, however, the results agreed with those from other methods

  5. Doppler ultrasound study of penis in men with systemic sclerosis: a correlation with Doppler indices of renal and digital arteries.

    PubMed

    Rosato, E; Barbano, B; Gigante, A; Cianci, R; Molinaro, I; Quarta, S; Digiulio, M A; Messineo, D; Pisarri, S; Salsano, F

    2013-01-01

    Erectile dysfunction (ED) prevalence in male systemic sclerosis (SSc) is high and its pathogenesis is unclear. The aim of the study is to assess correlation between Doppler ultrasound indices of penis and kidneys or digital arteries in male systemic sclerosis. Fourteen men with systemic sclerosis were enrolled in this study. Erectile function was investigated by the International Index of Erectile Function-5. Peak systolic velocity, end diastolic velocity, resistive index, pulsative index, and systolic/diastolic ratio were measured on the cavernous arteries at the peno-scrotal junction in the flaccid state, on the interlobar artery of both kidneys and all ten proper palmar digital arteries. Ten (71 percent) patients have an International Index of Erectile Function-5 less than 21. Reduction of penis peak systolic velocity was observed in all SSc subjects. Doppler indices of cavernous arteries correlate with the International Index of Erectile Function-5. The renal and digital arteries resistive index demonstrated a good correlation (p less than 0.0001) with International Index of Erectile Function-5. A positive correlation exists between penis and kidney arteries Doppler indices: end diastolic velocity (p less than 0.05, r=0.54), resistive index (p less than 0.0001, r=0.90), systolic/diastolic ratio (p less than 0.01, r=0.69). A positive correlation was observed between penis and digital arteries Doppler indices: peak systolic velocity (p less than 0.01, r=0.68), end diastolic velocity (p less than 0.01, r=0.75), resistive index (p less than 0.001, r=0.79), systolic/diastolic ratio (p less than 0.05, r=0.59). A correlation exists between arterial impairment of penis and renal or digital arteries.

  6. Ultrasonic distance and velocity measurement using a pair of LPM signals for cross-correlation method: improvement of Doppler-shift compensation and examination of Doppler velocity estimation.

    PubMed

    Hirata, Shinnosuke; Kurosawa, Minoru Kuribayashi

    2012-09-01

    Real-time distance measurement of a moving object with high accuracy and high resolution using an ultrasonic wave is difficult due to the influence of the Doppler effect or the limit of the calculation cost of signal processing. An over-sampling signal processing method using a pair of LPM signals has been proposed for ultrasonic distance and velocity measurement of moving objects with high accuracy and high resolution. The proposed method consists of cross correlation by single-bit signal processing, high-resolution Doppler velocity estimation with wide measurement range and low-calculation-cost Doppler-shift compensation. The over-sampling cross-correlation function is obtained from cross correlation by single-bit signal processing with low calculation cost. The Doppler velocity and distance of the object are determined from the peak interval and peak form in the cross-correlation function by the proposed method of Doppler velocity estimation and Doppler-shift compensation. In this paper, the proposed method of Doppler-shift compensation is improved. Accuracy of the determined distance was improved from approximately within ±140μm in the previous method to approximately within ±10μm in computer simulations. Then, the proposed method of Doppler velocity estimation is evaluated. In computer simulations, accuracy of the determined Doppler velocity and distance were demonstrated within ±8.471mm/s and ±13.87μm. In experiments, Doppler velocities of the motorized stage could be determined within ±27.9mm/s.

  7. Influence of sub-Doppler force on the Doppler trap parameters of a magneto-optical trap

    NASA Astrophysics Data System (ADS)

    Noh, Heung-Ryoul; Kim, Kihwan

    2005-05-01

    We have measured the trap frequency as well as the damping coefficient of a magneto-optical trap by using a transient oscillation method. The dependence of such trap properties on the various experimental parameters such as the cooling laser intensity, detuning, and magnetic field gradient is investigated. We find that the measured trap frequency is in excellent agreement with the simple rate-equation analysis based on the Doppler cooling theory. In contrast, the damping coefficient is about twice larger than the calculated one, which is attributed to the existence of the sub-Doppler trap near the trap center. We also have shown for the multi-level atom the trap parameters are affected by the laser intensity, detuning of other directions. From the measurement of the damping coefficient, we have found that the trap parameters are affected by the sub-Doppler force. These observations are explained by the direct calculation of the force where the detuning of transverse laser is different from the considered axis.

  8. Realizing Tunable Inverse and Normal Doppler Shifts in Reconfigurable RF Metamaterials.

    PubMed

    Ran, Jia; Zhang, Yewen; Chen, Xiaodong; Fang, Kai; Zhao, Junfei; Sun, Yong; Chen, Hong

    2015-06-26

    The Doppler effect has well-established applications in astronomy, medicine, radar and metrology. Recently, a number of experimental demonstrations of the inverse Doppler effect have begun to appear. However, the inverse Doppler effect has never been observed on an electronically reconfigurable system with an external electromagnetic wave source at radio frequencies (RF) in experiment. Here we demonstrate an experimental observation of the inverse Doppler shift on an electronically reconfigurable RF metamaterial structure, which can exhibit anomalous dispersion, normal dispersion or a stop band, depending on an applied bias voltage. Either inverse or normal Doppler shift is realized by injecting an external RF signal into the electronically reconfigurable metamaterial, on which an electronically controllable moving reflective boundary is formed. The effective velocity of this boundary and the resulting frequency shift can be tuned over a wide range by a digital switching circuit. This work is expected to open up possibilities in applying the inverse Doppler effect in wireless communications, radar and satellite navigation.

  9. Shear-layer detection in poststenotic flow by spectrum analysis of Doppler signals.

    PubMed

    Tamura, T; Fronek, A

    1988-11-01

    Spectrum analysis of the Doppler signals was performed 0.5 tube diameters downstream from an axisymmetric constriction with an area reduction of 80 percent in steady flow at a jet Reynolds number of 2840. Both pulsed and continuous wave (CW) Doppler spectra showed significant reverse flow components in the separated flow. The pulsed Doppler spectra exhibited sudden changes when the sample volume crossed the shear layer between the center jet and the separated flow. A power spectrum equation was theoretically derived from continuity of flow to define the Doppler shift frequency for the shear layer velocity. The CW Doppler spectrum showed a minimum spectrum density at a frequency which equalled the shear layer Doppler shift frequency derived from the equation. The pulsed spectra exhibited the sudden changes at the same frequency as well.

  10. [Noise and speckle reduction in ultrasound Doppler blood flow spectrograms by using MP-PCNN].

    PubMed

    Li, Haiyan; Ma, Yue; Zhang, Yufeng; Shu, Xinling

    2011-10-01

    To reduce background noise and Dopplar speckle in the spectrogram of ultrasound Doppler blood flow signals, a novel method, called Matching Pursuit with threshold decaying pulse coupled neural network (MP-PCNN), has been proposed. The proposed method used an iterative algorithm, which decomposed the ultrasound Doppler signals into linear expansion of atoms in a time-frequency dictionary by using the Matching Pursuit (MP) for de-noising the ultrasound Doppler signal. Subsequently, a simplified unidirectional pulse coupled neural network was applied to calculate the firing matrix of the denoised spectrogram. The Doppler speckles were located and removed through analyzing and processing the PCNN firing matrix. Experiments were conducted on simulation signals which SNRs were 0dB, 5dB and 10dB. The result showed that the MP-PCNN performed effectively in reducing noise, eliminating Doppler speckles, and achieved better performance than exiting noise and speckle suppression algorithm for Doppler ultrasound blood flow spectrogram.

  11. Spacecraft Doppler Tracking as a Narrow-Band Detector of Gravitational Waves

    NASA Technical Reports Server (NTRS)

    Tinto, Massimo

    1997-01-01

    We discuss spacecraft Doppler tracking for detecting gravitational waves in which Doppler data recorded on the ground are linearly combined with Doppler measurements made on board a spacecraft. By using the four-link radio system first proposed by Vessot and Levine, we derive a new method for removing from the combined data the frequency fluctuations due to the Earth troposphere, ionosphere, and mechanical vibrations of the antenna on the ground.

  12. Compact, Engineered 2-Micron Coherent Doppler Wind Lidar Prototype for Field and Airborne Evaluation

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.; Amzajerdian, Farzin; Koch, Grady J.

    2006-01-01

    The state-of-the-art 2-micron coherent Doppler wind lidar breadboard at NASA/LaRC will be engineered and compactly packaged consistent with future aircraft flights. The packaged transceiver will be integrated into a coherent Doppler wind lidar system test bed at LaRC. Atmospheric wind measurements will be made to validate the packaged technology. This will greatly advance the coherent part of the hybrid Doppler wind lidar solution to the need for global tropospheric wind measurements.

  13. Coherent Doppler Lidar Deployment in the Canopy Horizontal Array Turbulence Study

    DTIC Science & Technology

    2008-02-06

    REPORT Coherent Doppler Lidar Deployment in the Canopy Horizontal Array Turbulence Study 14. ABSTRACT 16. SECURITY CLASSIFICATION OF: The PI’s and ASU...students/staff deployed their coherent Doppler lidar from May 9, 2007 to June 11, 2007 in support of the Canopy Horizontal Array Turbulence Study...DATES COVERED (From - To) 29-Mar-2007 Standard Form 298 (Rev 8/98) Prescribed by ANSI Std. Z39.18 - 28-Dec-2007 Coherent Doppler Lidar Deployment in

  14. Laser Doppler velocity measurement without directional ambiguity by using frequency shifted incident beams

    NASA Technical Reports Server (NTRS)

    Mazumder, M. K.

    1970-01-01

    Laser Doppler heterodyning system for velocity measurements without directional ambiguity, employing incident beams of different frequencies through rotating diffraction grating or Bragg cell application

  15. Design and Implementation of High Frequency Ultrasound Pulsed-Wave Doppler Using FPGA

    PubMed Central

    Hu, Chang-hong; Zhou, Qifa; Shung, K. Kirk

    2009-01-01

    The development of a field-programmable gate array (FPGA)-based pulsed-wave Doppler processing approach in pure digital domain is reported in this paper. After the ultrasound signals are digitized, directional Doppler frequency shifts are obtained with a digital-down converter followed by a low-pass filter. A Doppler spectrum is then calculated using the complex fast Fourier transform core inside the FPGA. In this approach, a pulsed-wave Doppler implementation core with reconfigurable and real-time processing capability is achieved. PMID:18986909

  16. Dispersed single-phase-step Michelson interferometer for Doppler imaging using sunlight.

    PubMed

    Wan, Xiaoke; Ge, Jian

    2012-09-15

    A Michelson interferometer is dispersed with a fiber array-fed spectrograph, providing 59 Doppler sensing channels using sunlight in the 510-570 nm wavelength region. The interferometer operates at a single-phase-step mode, which is particularly advantageous in multiplexing and data processing compared to the phase-stepping mode of other interferometer spectrometer instruments. Spectral templates are prepared using a standard solar spectrum and simulated interferometer modulations, such that the correlation function with a measured 1D spectrum determines the Doppler shift. Doppler imaging of a rotating cylinder is demonstrated. The average Doppler sensitivity is ~12 m/s, with some channels reaching ~5 m/s.

  17. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    PubMed Central

    2017-01-01

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography. PMID:28219004

  18. Reducing registration error in cross-beam vector doppler imaging with position sensor.

    PubMed

    Xu, Canxing; Beach, Kirk W; Leotta, Daniel; Stuzman, Edward; Kim, Yongmin

    2009-01-01

    Various vector Doppler methods have been proposed in the last several decades to overcome the Doppler angle dependency in both conventional spectral Doppler and color Doppler by measuring both the speed and direction of blood flow. However, they have not been adopted for routine use because most of them require specialized hardware, which is not available in commercial ultrasound systems. An alternative approach (cross-beam method) that uses color Doppler images obtained from different steered beam angles is more feasible, but there is error in registering multiple color Doppler images because they are not acquired simultaneously. To alleviate this problem, we have evaluated a cross-beam vector Doppler system that registers spatially with a position sensor two color Doppler images from two different angles and temporally with ECG synchronization. The registration error was reduced to an average of 0.92 mm from 2.49 mm in 9 human subjects. Vector Doppler carotid artery images of a healthy subject and a patient with atherosclerotic plaques are also presented.

  19. Suspected Fetal Growth Restriction at 37 Weeks: A Comparison of Doppler and Placental Pathology

    PubMed Central

    Millington, Karmaine A.; Ibekwe, Tochi O.; Ural, Serdar H.

    2017-01-01

    Objective. Our objective was determining if abnormal Doppler evaluation had a higher prevalence of placental pathology compared to normal Doppler in suspected fetal growth restriction (FGR) of cases delivered at 37 weeks. Study Design. This retrospective cohort study of suspected FGR singletons with antenatal Doppler evaluation delivered at 37 weeks had a primary outcome of the prevalence of placental pathology related to FGR. Significance was defined as p ≤ 0.05. Results. Of 100 pregnancies 46 and 54 were in the abnormal and normal Doppler cohorts, respectively. Placental pathology was more prevalent with any abnormal Doppler, 84.8% versus 55.6%, odds ratio (OR) 4.46, 95% confidence interval (CI): 1.55, 13.22, and p = 0.002. Abnormal middle cerebral artery (MCA) Doppler had a higher prevalence: 96.2% versus 54.8%, OR 20.7, 95% CI: 2.54, 447.1, and p < 0.001. Conclusion. Abnormal Doppler was associated with more placental pathology in comparison to normal Doppler in fetuses with suspected FGR. Abnormal MCA Doppler had the strongest association.

  20. A New Active Cavitation Mapping Technique for Pulsed HIFU Applications – Bubble Doppler

    PubMed Central

    Li, Tong; Khokhlova, Tatiana; Sapozhnikov, Oleg; Hwang, Joo Ha; Sapozhnikov, Oleg; O’Donnell, Matthew

    2015-01-01

    In this work, a new active cavitation mapping technique for pulsed high-intensity focused ultrasound (pHIFU) applications termed bubble Doppler is proposed and its feasibility tested in tissue-mimicking gel phantoms. pHIFU therapy uses short pulses, delivered at low pulse repetition frequency, to cause transient bubble activity that has been shown to enhance drug and gene delivery to tissues. The current gold standard for detecting and monitoring cavitation activity during pHIFU treatments is passive cavitation detection (PCD), which provides minimal information on the spatial distribution of the bubbles. B-mode imaging can detect hyperecho formation, but has very limited sensitivity, especially to small, transient microbubbles. The bubble Doppler method proposed here is based on a fusion of the adaptations of three Doppler techniques that had been previously developed for imaging of ultrasound contrast agents – color Doppler, pulse inversion Doppler, and decorrelation Doppler. Doppler ensemble pulses were interleaved with therapeutic pHIFU pulses using three different pulse sequences and standard Doppler processing was applied to the received echoes. The information yielded by each of the techniques on the distribution and characteristics of pHIFU-induced cavitation bubbles was evaluated separately, and found to be complementary. The unified approach - bubble Doppler – was then proposed to both spatially map the presence of transient bubbles and to estimate their sizes and the degree of nonlinearity. PMID:25265178

  1. Data Quality Control for Vessel Mounted Acoustic Doppler Current Profiler. Application for the Western Mediterranean Sea

    NASA Technical Reports Server (NTRS)

    Garcia-Gorriz, E.; Front, J.; Candela, J.

    1997-01-01

    A systematic Data Quality Checking Protocol for vessel Mounted Acoustic Doppler Current Profiler observations is proposed. Previous-to-acquisition conditions are considered along with simultaneous ones.

  2. Implementation of on-the-fly doppler broadening in MCNP

    SciTech Connect

    Martin, W. R.; Wilderman, S.; Brown, F. B.; Yesilyurt, G.

    2013-07-01

    A new method to obtain Doppler broadened cross sections has been implemented into MCNP, removing the need to generate cross sections for isotopes at problem temperatures. When a neutron of energy E enters a material region that is at some temperature T, the cross sections for that material at temperature T are immediately obtained 'on-the-fly' (OTF) by interpolation using a high order functional expansion for the temperature dependence of the Doppler-broadened cross section for that isotope at the neutron energy E. The OTF cross sections agree with the NJOY-based cross sections for all neutron energies and all temperatures in the range specified by the user, e.g., 250 K - 3200 K. The OTF methodology has been successfully implemented into the MCNP Monte Carlo code and has been tested on several test problems by comparing MCNP with conventional ACE cross sections versus MCNP with OTF cross sections. The test problems include the Doppler defect reactivity benchmark suite and two full-core VHTR configurations, including one with multiphysics coupling using RELAP5-3D/ATHENA for the thermal-hydraulic analysis. The comparison has been excellent, verifying that the OTF libraries can be used in place of the conventional ACE libraries generated at problem temperatures. In addition, it has been found that the OTF methodology greatly reduces the complexity of the input for MCNP, resulting in an order of magnitude decrease in the number of input lines for full-core configurations. Finally, for full-core problems with multiphysics feedback, the memory required to store the cross section data is considerably reduced with OTF cross sections and the additional computational effort with OTF is modest, on the order of 10-15%. (authors)

  3. 94 GHz doppler wind radar satellite mission concept

    NASA Astrophysics Data System (ADS)

    Lin, Chung-Chi; Rommen, Björn; Buck, Christopher; Schüttemeyer, Dirk

    2015-10-01

    Extreme weather such as storms, hurricanes and typhoons, also called `high impact weather', is a high priority area of research for the atmospheric dynamics and meteorological science communities. 94 GHz Doppler wind radar satellite mission concepts have been elaborated, which use cloud and precipitation droplets/particles as tracers to measure 3-D wind fields. The so-called polarisation-diversity pulse-pair (PDPP) technique enables to derive line-of-sight wind speed with good accuracy (< 2-3 m/s) and large unambiguous dynamic range (e.g. 75 m/s). Two distinct system concepts have been elaborated: (1) a conically scanning radar concept with large coverage (> 800 km) and ˜50 km along-track sampling, and; (2) a stereo viewing concept with high sampling resolution (< 4 km) within an inclined cut through the atmosphere. The former concept is adequate for studying large-scale severe/extreme weather systems, whereas the latter would be more suitable for understanding of small-scale convective phenomena. For demonstrating the potential of the FDPP technique for deriving accurate Doppler observations, ground-based and airborne Doppler radar campaigns are in preparation. The Galileo 94 GHz radar, upgraded recently to include a FDPP capability, at Chilbolton in the UK, will be used for an extended ground-based campaign (6 months). For the airborne campaign, the dual-frequency (9.4 + 94 GHz) NAWX radar on board a Convair-580 aircraft of the National Science Council of Canada will be upgraded and flown. This paper describes the observation requirements, preliminary satellite mission concepts, associated wind retrieval aspects and the planned demonstration campaigns.

  4. From HARPS to CODEX: exploring the limits of Doppler measurements

    NASA Astrophysics Data System (ADS)

    Pepe, F. A.; Lovis, C.

    2008-08-01

    Only 3 6 years ago, the Doppler technique was believed to have reached its final limitations in measuring stellar velocities and finding extra-solar planets. The 3 4 m s-1 precision level achieved, at that time, by various teams, was certainly limited by instrumental performances, but also constrained, as believed by a part of the community, by intrinsic stellar limitations. The advent of HARPS drastically changed this view. The instrument demonstrated, through its recent discoveries, that stars more 'stable' than 1 m s-1 actually exist, and that their radial velocity (RV) can be measured at that level of precision. Short-term precision of 20 cm s-1 rms and long-term precision of the order of 30 60 cm s-1 rms have been actually achieved on real stars, showing that RVs still harbor a great potential, and not only in the domain of extra-solar planets. Indeed, HARPS inspired the CODEX@ELT experiment for the direct determination of the expansion of the Universe, measuring the Doppler shift of Ly-α forest lines as a function of time. This experiment calls for a Doppler precision as low as 1 cm s-1, which in turn inspires new possibilities in the domain of extra-solar planets. We will investigate the obstacles on the way to cm s-1 precision. The discussion presented here will be based on our experience with HARPS and what we consider to be the current limitations set by the instrument, telescope, atmosphere and star. Finally, we will also provide an outlook on possible improvements and expected performances, which will finally define new scientific opportunities.

  5. The NPL Doppler fetal heart beat detector test facility.

    PubMed

    Bond, A D; Preston, R C

    1998-03-01

    There are many thousands of Doppler fetal heart beat detectors in medical use and many different detector manufacturers but, until recently, there has been no well-defined quantitative method for measuring the sensitivity of these detectors and, therefore, no way of directly comparing their technical performance under standardised test conditions. At NPL, we have developed a reference test facility for measuring detector sensitivity to meet the needs of manufacturers, and to comply with the requirements of an international standard (IEC 1995) that defines methods of measurement of the sensitivity of fetal heart beat detectors. The test facility has primarily been developed for detectors operating at a transmitted frequency of 2 MHz and with Doppler shifts of up to 1 kHz. The detectors are tested by directing the ultrasound beam at a small moving target being driven at a constant velocity, and then monitoring the output signal from the detector, which will be at the Doppler shift frequency. To determine the sensitivity, attenuators are inserted into the beam until the output signal is reduced to 6 dB above the noise level. The sensitivity is calculated by adding the final signal level above the noise to the total insertion loss of the attenuators in the ultrasound path and the reflection loss of the target. A crucial aspect of this calculation is the knowledge of the target strengths and characteristics. This has already been extensively studied (Preston and Bond 1997) over the frequency range of interest. The NPL test facility developed for undertaking the sensitivity measurements is described, including an assessment of the uncertainties in such a measurement and solutions to problems encountered along the way.

  6. Real-time and interactive virtual Doppler ultrasound

    NASA Astrophysics Data System (ADS)

    Hirji, Samira; Downey, Donal B.; Holdsworth, David W.; Steinman, David A.

    2005-04-01

    This paper describes our "virtual" Doppler ultrasound (DUS) system, in which colour DUS (CDUS) images and DUS spectrograms are generated on-the-fly and displayed in real-time in response to position and orientation cues provided by a magnetically tracked handheld probe. As the presence of complex flow often confounds the interpretation of Doppler ultrasound data, this system will serve to be a fundamental tool for training sonographers and gaining insight into the relationship between ambiguous DUS images and complex blood flow dynamics. Recently, we demonstrated that DUS spectra could be realistically simulated in real-time, by coupling a semi-empirical model of the DUS physics to a 3-D computational fluid dynamics (CFD) model of a clinically relevant flow field. Our system is an evolution of this approach where a motion-tracking device is used to continuously update the origin and orientation of a slice passing through a CFD model of a stenosed carotid bifurcation. After calibrating our CFD model onto a physical representation of a human neck, virtual CDUS images from an instantaneous slice are then displayed at a rate of approximately 15 Hz by simulating, on-the-fly, an array of DUS spectra and colour coding the resulting spectral mean velocity using a traditional Doppler colour scale. Mimicking a clinical examination, the operator can freeze the CDUS image on-screen, and a spectrogram corresponding to the selected sample volume location is rendered at a higher frame rate of at least 30 Hz. All this is achieved using an inexpensive desktop workstation and commodity graphics card.

  7. Coherent Doppler Laser Radar: Technology Development and Applications

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.; Arnold, James E. (Technical Monitor)

    2000-01-01

    NASA's Marshall Space Flight Center has been investigating, developing, and applying coherent Doppler laser radar technology for over 30 years. These efforts have included the first wind measurement in 1967, the first airborne flights in 1972, the first airborne wind field mapping in 1981, and the first measurement of hurricane eyewall winds in 1998. A parallel effort at MSFC since 1982 has been the study, modeling and technology development for a space-based global wind measurement system. These endeavors to date have resulted in compact, robust, eyesafe lidars at 2 micron wavelength based on solid-state laser technology; in a factor of 6 volume reduction in near diffraction limited, space-qualifiable telescopes; in sophisticated airborne scanners with full platform motion subtraction; in local oscillator lasers capable of rapid tuning of 25 GHz for removal of relative laser radar to target velocities over a 25 km/s range; in performance prediction theory and simulations that have been validated experimentally; and in extensive field campaign experience. We have also begun efforts to dramatically improve the fundamental photon efficiency of the laser radar, to demonstrate advanced lower mass laser radar telescopes and scanners; to develop laser and laser radar system alignment maintenance technologies; and to greatly improve the electrical efficiency, cooling technique, and robustness of the pulsed laser. This coherent Doppler laser radar technology is suitable for high resolution, high accuracy wind mapping; for aerosol and cloud measurement; for Differential Absorption Lidar (DIAL) measurements of atmospheric and trace gases; for hard target range and velocity measurement; and for hard target vibration spectra measurement. It is also suitable for a number of aircraft operations applications such as clear air turbulence (CAT) detection; dangerous wind shear (microburst) detection; airspeed, angle of attack, and sideslip measurement; and fuel savings through

  8. Radio wave phase scintillation and precision Doppler tracking of spacecraft

    NASA Astrophysics Data System (ADS)

    Armstrong, J. W.

    Phase scintillation caused by propagation through solar wind, ionospheric, and tropospheric irregularities is a noise process for many spacecraft radio science experiments. In precision Doppler tracking observations, scintillation can be the dominant noise process. Scintillation statistics are necessary for experiment planning and in design of signal processing procedures. Here high-precision tracking data taken with operational spacecraft (Mars Observer, Galileo, and Mars Global Surveyor) and ground systems are used to produce temporal statistics of tropospheric and plasma phase scintillation. The variance of Doppler frequency fluctuations is approximately decomposed into two propagation processes. The first, associated with distributed scattering along the sight line in the solar wind, has a smooth spectrum. The second, associated principally with localized tropospheric scattering for X-band experiments, has a marked autocorrelation peak at the two-way light time between the Earth and the spacecraft (thus a cosine-squared modulation of the fluctuation power spectrum). For X-band data taken in the antisolar hemisphere the average noise levels of this process are in good agreement with average tropospheric noise levels determined independently from water vapor radiometer observations and radio interferometic data. The variance of the process having a smooth spectrum is consistent with plasma noise levels determined independently from dual-frequency observations of the Viking spacecraft made at comparable Sun-Earth-spacecraft angles. The observations reported here are used to refine the propagation noise model for Doppler tracking of deep space probes. In particular, they can be used to predict propagation noise levels for high-precision X- and Ka-band tracking observations (e.g., atmosphere/ionosphere/ring occultations, celestial mechanics experiments, and gravitational wave experiments) to be done using the Cassini spacecraft.

  9. Novel laser Doppler flowmeter for pulpal blood flow measurements

    NASA Astrophysics Data System (ADS)

    Zang, De Yu; Millerd, James E.; Wilder-Smith, Petra B. B.; Arrastia-Jitosho, Anna-Marie A.

    1996-04-01

    We have proposed and experimentally demonstrated a new configuration of laser Doppler flowmetry for dental pulpal blood flow measurements. To date, the vitality of a tooth can be determined only by subjective thermal or electric tests, which are of questionable reliability and may induced pain in patient. Non-invasive techniques for determining pulpal vascular reactions to injury, treatment, and medication are in great demand. The laser Doppler flowmetry technique is non-invasive; however, clinical studies have shown that when used to measure pulpal blood flow the conventional back-scattering Doppler method suffers from low signal-to-noise ratio (SNR) and unreliable flux readings rendering it impossible to calibrate. A simplified theoretical model indicates that by using a forward scattered geometry the detected signal has a much higher SNR and can be calibrated. The forward scattered signal is readily detectable due to the fact that teeth are relatively thin organs with moderate optical loss. A preliminary experiment comparing forward scattered detection with conventional back- scattered detection was carried out using an extracted human molar. The results validated the findings of the simple theoretical model and clearly showed the utility of the forward scattering geometry. The back-scattering method had readings that fluctuated by as much as 187% in response to small changes in sensor position relative to the tooth. The forward scattered method had consistent readings (within 10%) that were independent of the sensor position, a signal-to-noise ratio that was at least 5.6 times higher than the back-scattering method, and a linear response to flow rate.

  10. Role of Ultrasound with Color Doppler in Acute Scrotum Management

    PubMed Central

    Agrawal, Alka M.; Tripathi, Prem Siddharth; Shankhwar, Amit; Naveen, C.

    2014-01-01

    Background and Objective: An acute scrotum is defined as acute pain with or without scrotal swelling, may be accompanied by local signs or general symptoms. Acute scrotal pain is a medical emergency. Depending on cause, the management is entirely different. Torsion of testis and strangulated hernia are surgical emergency; whereas, epididymo-orchitis is treated by medicines. Testicular trauma and obstructed hernia can be differentiated by taking history from patient. Physical examination adds only a little information. Color Doppler ultrasound (US) is the modality of choice to differentiate testicular torsion from inflammatory conditions and can thus help in avoiding unnecessary surgical explorations. Subjects and Methods: A study on 50 patients was conducted who were referred with history of acute scrotal pain to our department between January 2013 and January 2014. Trauma and scrotal mass were excluded from the study. The clinical presentation, outcome, and US results were analyzed. Results: Color Doppler sonography yielded a positive and negative predictive value (PPV and NPV) of 100% each for torsion, whereas, 93.9 and 70.6% for epididymo-orchitis, respectively; a sensitivity and specificity of 100% for torsion, whereas, for epididymo-orchitis it was found to be 86.1 and 85.7%, respectively. In cases of incomplete or early torsion, some residual perfusion may be detected leading to false-negative results. Conclusion: We therefore conclude that color Doppler sonography can reliably rule out testicular torsion and can thus help in avoiding unnecessary surgical explorations. Hence, it can significantly improve outcome and decrease morbidity of patient. It is an accurate, rapid, nonexpensive, nonionizing, important adjunct to clinical assessment of scrotum. PMID:25657954

  11. Coupling Between Doppler Radar Signatures and Tornado Damage Tracks

    NASA Technical Reports Server (NTRS)

    Jedlovec, Gary J.; Molthan, Andrew L.; Carey, Lawrence; Carcione, Brian; Smith, Matthew; Schultz, Elise V.; Schultz, Christopher; Lafontaine, Frank

    2011-01-01

    On April 27, 2011, the southeastern United States was raked with several episodes of severe weather. Numerous tornadoes caused extensive damage, and tragically, the deaths of over 300 people. In Alabama alone, there were 61 confirmed tornados, 4 of them produced EF5 damage, and several were on the ground an hour or more with continuous damage tracks exceeding 80km. The use of Doppler radars covering the region provided reflectivity and velocity signatures that allowed forecasters to monitors the severe storms from beginning to end issuing hundreds of severe weather warnings throughout the day. Meteorologists from the the NWS performed extensive surveys to assess the intensity, duration, and ground track of tornadoes reported during the event. Survey activities included site visits to the affected locations, analysis of radar and satellite data, aerial surveys, and interviews with eyewitnesses. Satellite data from NASA's MODIS and ASTER instruments played a helpful role in determining the location of tornado damage paths and in the assessment. High resolution multispectral and temporal composites helped forecasters corroborate their damage assessments, determine starting and ending points for tornado touchdowns, and helped to provide forecasters with a better big-picture view of the damage region. The imagery also helped to separate damage from the April 27th tornados from severe weather that occurred earlier that month. In a post analysis of the outbreak, tornado damage path signatures observed in the NASA satellite data have been correlated to "debris ball" signatures in the NWS Doppler radars and a special ARMOR dual-polarization radar operated by the University of Alabama Huntsville during the event. The Doppler radar data indicates a circular enhanced reflectivity signal and rotational couplet in the radial velocity likely associated with the tornado that is spatially correlated with the damage tracks in the observed satellite data. An algorithm to detect and

  12. Duplex Doppler ultrasound study of the temporomandibular joint.

    PubMed

    Stagnitti, A; Marini, A; Impara, L; Drudi, F M; Lo Mele, L; Lillo Odoardi, G

    2012-06-01

    Sommario INTRODUZIONE: La fisiologia articolare dell’articolazione temporo-mandibolare (ATM) può essere esaminata sia dal punto di vista clinico che strumentale. La diagnostica per immagini ha da tempo contribuito con la risonanza magnetica (RM) e anche con la radiografia (Rx) e la tomografia computerizzata (TC) all’analisi della morfologia dei capi articolari e della cinetica condilare. L’esame duplex-ecodoppler è una metodica di largo impiego nello studio delle strutture in movimento in particolar modo a livello delle strutture del sistema vascolare. MATERIALI E METODI: È stata utilizzata un’apparecchiatura Toshiba APLIO SSA-770A, con l’uso di tecnica duplex-ecodoppler multi display, che consente la visualizzazione contemporanea dell’immagine ecografica e dei segnali Doppler utilizzando una sonda lineare del tipo phased array con cristalli trasduttori funzionanti ad una frequenza fondamentale di 6 MHz per gli spettri Doppler pulsati e 7.5 MHz per l’imaging ecografico. Sono stati esaminati nel Dipartimento di Scienze Radiologiche, Oncologiche e Anatomo-patologiche dell’Università “Sapienza” di Roma, 30 pazienti del reparto di Ortognatodonzia dell’Istituto di Odontoiatria della stessa Università. RISULTATI: Nei pazienti normali si è ottenuta un’alternanza regolare degli spettri Doppler, mentre nei soggetti con disfunzioni del complesso condilo-meniscale, si è persa la regolarità della sommatoria degli spettri di Fourier, con altezze incostanti in relazione a spostamenti irregolari del complesso condilo-meniscale. CONCLUSIONI: L’esame ecodoppler si è dimostrato, in tutti i pazienti, capace di discriminare quelli normali dai patologici e tra questi ultimi ha permesso di identificare gli aspetti più significativi delle patologie disfunzionali.

  13. [Doppler ultrasound diagnosis in post-term pregnancy].

    PubMed

    Jörn, H; Funk, A; Fendel, H

    1993-09-01

    The capability of Doppler flow velocimetry to predict intrauterine growth retardation is well known. The increased morbidity and mortality rate of postterm newborns is also well known. The aim of our study was to examine if Doppler flow velocimetry is able to indicate foetal jeopardy in the postterm period. Flow velocimetry of the foetal descending aorta, the umbilical artery, the uterine arteries and in 59 cases also the foetal middle cerebral artery was obtained from 167 pregnancies after 40 completed weeks of gestation. We found significant changes of normal values in prolonged pregnancy compared to third trimester normal values, examining the mean velocity of the foetal descending aorta and the S/D-ratio of the umbilical artery. No clinically significant changes were found examining the S/D-ratio of the uterine arteries and the pulsatility index of the foetal middle cerebral artery. Daily examinations of the foetal descending aorta were carried out in 23 and of the umbilical artery in 19 cases during the last four days before delivery, and in 11 cases of the foetal middle cerebral artery during the last three days before delivery. We did not find significant changes in the medians of the mean velocity of the foetal aorta, of the S/D-ratio of the umbilical artery and of the pulsatility index of the foetal middle cerebral artery. Measurement of sensitivity and positive predictive value of the four arteries examined showed, that Doppler ultrasound could not predict small for date infants or Caesarean section because of foetal distress.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Observing crosswind over urban terrain using scintillometer and Doppler lidar

    NASA Astrophysics Data System (ADS)

    van Dinther, D.; Wood, C. R.; Hartogensis, O. K.; Nordbo, A.; O'Connor, E. J.

    2014-07-01

    In this study, the crosswind (wind component perpendicular to a path, U\\bot) is measured by a scintillometer and Doppler lidar above the urban environment of Helsinki, Finland, for 3 weeks. The scintillometer allows acquisition of a path-averaged value of U\\bot (U\\bot), while the Doppler lidar allows acquisition of path-resolved U\\bot (U\\bot (x), where x is the position along the path). The goal of this study is to evaluate the applicability of scintillometer U\\bot-measurements for conditions where U\\bot (x) is variable. If the scintillometer is applicable in such variable-wind conditions, it can also be used in the urban environment. Two methods were applied to obtain U\\bot from the scintillometer signal; the cumulative spectrum method (relies on scintillation spectra), and the lookup table method (relies on time-lagged correlation functions). Both methods compared reasonably well with the Doppler lidar measurements, especially considering the challenging urban environment in which they were measuring; with RMSE of 0.71 and 0.73 m s-1. This indicates that both measurement technologies are able to obtain U\\bot in the complex urban environment. The in detail investigation of four cases indicate that the cumulative spectrum method is less susceptible to a variable U\\bot (x) than the lookup table method. However, the lookup table method can be adjusted to improve its capabilities to obtain U\\bot for conditions where U\\bot (x) is variable.

  15. Numerical computation of doppler-broadening in the resonance domain

    SciTech Connect

    Sanchez, R.

    2013-07-01

    We have implemented an accurate and fast calculation of the Doppler-broadened kernel PT(E {yields} E') for neutron elastic scattering based on a gas model. An exponential cutoff which accounts for the asymptotic behavior of the error function helps limit the range of integration while eliminating difference effects. This allows for calculating a kernel library for {sup 238}U over a very fine energy grid covering the resonance range in only a few hours in a laptop. We give an example showing the impact of {sup 238}U elastic up-scattering on the values of self shielded cross sections. (authors)

  16. Analyzing left ventricular function in mice with Doppler echocardiography.

    PubMed

    Fayssoil, Abdallah; Tournoux, François

    2013-07-01

    Mice are widely used in heart failure research. Accurate evaluation of cardiac structure and function is key to modern cardiovascular research. Doppler echocardiography is a simple, reproducible, and non-invasive method, which allows a longitudinal study of these small animals. Besides common parameters such as left ventricular chamber size, mass, and function, new emerging echo tools are of great interest for small animal imaging. In this review, we describe the technical issues linked to murine cardiovascular anatomy and physiology and the most current echo parameters that can be used.

  17. Transcranial Doppler: Techniques and advanced applications: Part 2

    PubMed Central

    Sharma, Arvind K.; Bathala, Lokesh; Batra, Amit; Mehndiratta, Man Mohan; Sharma, Vijay K.

    2016-01-01

    Transcranial Doppler (TCD) is the only diagnostic tool that can provide continuous information about cerebral hemodynamics in real time and over extended periods. In the previous paper (Part 1), we have already presented the basic ultrasound physics pertaining to TCD, insonation methods, and various flow patterns. This article describes various advanced applications of TCD such as detection of right-to-left shunt, emboli monitoring, vasomotor reactivity (VMR), monitoring of vasospasm in subarachnoid hemorrhage (SAH), monitoring of intracranial pressure, its role in stoke prevention in sickle cell disease, and as a supplementary test for confirmation of brain death. PMID:27011639

  18. Laser Doppler anemometer measurements using nonorthogonal velocity components - Error estimates

    NASA Technical Reports Server (NTRS)

    Orloff, K. L.; Snyder, P. K.

    1982-01-01

    Laser Doppler anemometers (LDAs) that are arranged to measure nonorthogonal velocity components (from which orthogonal components are computed through transformation equations) are more susceptible to calibration and sampling errors than are systems with uncoupled channels. In this paper uncertainty methods and estimation theory are used to evaluate, respectively, the systematic and statistical errors that are present when such devices are applied to the measurement of mean velocities in turbulent flows. Statistical errors are estimated for two-channel LDA data that are either correlated or uncorrelated. For uncorrelated data the directional uncertainty of the measured velocity vector is considered for applications where mean streamline patterns are desired.

  19. Laser-scanning Doppler photoacoustic microscopy based on temporal correlation

    NASA Astrophysics Data System (ADS)

    Song, Wei; Liu, Wenzhong; Zhang, Hao F.

    2013-05-01

    We present a methodology to measure absolute flow velocity using laser-scanning photoacoustic microscopy. To obtain the Doppler angle, the angle between ultrasonic detection axis and flow direction, we extracted the distances between the transducer and three adjacent scanning points along the flow and repeatedly applied the law of cosines. To measure flow velocity along the ultrasonic detection axis, we calculated the time shift between two consecutive photoacoustic waves at the same scanning point, then converted the time shift to velocity according to the sound velocity and time interval between two laser illuminations. We verified our method by imaging flow phantoms.

  20. Fatigue damage in superalloys determined using Doppler broadening positron annihilation

    NASA Technical Reports Server (NTRS)

    Hoeckelman, Donald; Leighly, H. P., Jr.

    1990-01-01

    Axial fatigue specimens of three superalloys, Inconel 718, Incoloy 903 and Haynes 188, were machined from solution-heat-treated material and artificially aged. They were subjected to cyclic loading for a selected number of cycles after which the S parameter was determined using Doppler broadening positron annihilation. Initially, the S parameter decreased, followed by a large increase and a subsequent decline leading to fracture. This has been interpreted as the removal of residual vacancies, the introduction of new defects by cyclic loading, and, finally, a clustering of the defects as microcracks which grow to cause failure.

  1. A Doppler dimming determination of coronal outflow velocity

    NASA Technical Reports Server (NTRS)

    Strachan, Leonard; Kohl, John L.; Weiser, Heinz; Withbroe, George L.; Munro, Richard H.

    1993-01-01

    Outflow velocities in a polar coronal hole are derived from observations made during a 1982 sounding rocket flight. The velocity results are derived from a Doppler dimming analysis of resonantly scattered H I Ly-alpha. This analysis indicates radial outflow velocities of 217 km/s at 2 solar radii from sun-center with an uncertainty range of 153 to 251 km/s at a confidence level of 67 percent. These results are best characterized as strong evidence for supersonic outflow within 2 solar radii of sun-center in a polar coronal hole. Several means for obtaining improved accuracy in future observations are discussed.

  2. DC information preservation for cardiopulmonary monitor utilizing CW Doppler radar.

    PubMed

    Vergara, Alexander M; Boric-Lubecke, Olga; Lubecke, Victor M

    2008-01-01

    Direct conversion RF receivers introduce large DC offsets, reducing the dynamic range of the baseband signal. Coupled with the relatively small time varying signals in human vital sign monitoring using CW Doppler radar, extraction of cardio-pulmonary information becomes difficult. Previous DC offset compensation techniques utilizing AC coupling have proven detrimental to the performance of the system and the integrity of the low-frequency cardiopulmonary signals. A proposed system utilizing digitally controlled voltage feedback and center finding preserves the important DC information for optimal extraction of phase information in the quadrature system.

  3. Spinning disk calibration method and apparatus for laser Doppler velocimeter

    NASA Technical Reports Server (NTRS)

    Snyder, P. K. (Inventor)

    1986-01-01

    A method and apparatus for calibrating laser Doppler velocimeters having one or more intersecting beam pairs are described. These velocimeters measure fluid velocity by observing the light scattered by particles in the fluid stream. Moving fluid particulates are simulated by fine taut wires that are radially mounted on a disk that is rotated at a known velocity. The laser beam intersection locus is first aimed at the very center of the disk and then the disk is translated so that the locus is swept by the rotating wires. The radial distance traversed is precisely measured so that the velocity of the wires (pseudo particles) may be calculated.

  4. Development of Doppler Global Velocimetry as a Flow Diagnostics Tool

    NASA Technical Reports Server (NTRS)

    Meyers, James F.

    1995-01-01

    The development of Doppler global velocimetry is described from its inception to its use as a flow diagnostics tool. Its evolution is traced from an elementary one-component laboratory prototype, to a full three-component configuration operating in a wind tunnel at focal distances exceeding 15 m. As part of the developmental process, several wind tunnel flow field investigations were conducted. These included supersonic flow measurements about an oblique shock, subsonic and supersonic measurements of the vortex flow above a delta wing, and three-component measurements of a high-speed jet.

  5. Recalibration of Mount Wilson Doppler measurements (Research note)

    NASA Technical Reports Server (NTRS)

    Snodgrass, H. B.; Howard, R.; Webster, L.

    1984-01-01

    The dispersion calibration of spectroscopic velocity measurements made with the 150-ft tower telescope at Mt. Wilson Observatory is revised upward by 0.55 percent on the basis of observations of the six lines of comparable shape and equivalent width nearest the 5250.2-A line of Fe-I used in the solar Doppler rate measurements. The dispersion results are presented in a graph, and the superiority of the Kitt Peak wavelength tables (Pierce and Breckenridge, 1973) over those of Moore et al. (1966) is demonstrated. As a result of the recalibration, all recent spectroscopic velocities from this telescope must be revised downward by 0.55 percent.

  6. Fiber optic laser Doppler anemometry in swirling jets

    NASA Technical Reports Server (NTRS)

    Taghavi, R.; Rice, E. J.

    1991-01-01

    Time-averaged and fluctuating quantities are measured in a free turbulent swirling jet. Data from a two-component laser Doppler anemometry (LDA) are compared to the measurements via hot-wire and 5-hole pitot probes. To acquire the proper seeding density near the axis of a swirling jet for LDA measurements proved difficult. This is due to an imbalance of the centrifugal force and radial pressure gradient, which throws the seeding material off the axis. Despite this problem, close agreement between various measurement techniques is obtained.

  7. Current-induced spin-wave Doppler shift.

    PubMed

    Vlaminck, Vincent; Bailleul, Matthieu

    2008-10-17

    Spin transfer appears to be a promising tool for improving spintronics devices. Experiments that quantitatively access the magnitude of the spin transfer are required for a fundamental understanding of this phenomenon. By inductively measuring spin waves propagating along a permalloy strip subjected to a large electrical current, we observed a current-induced spin wave Doppler shift that we relate to the adiabatic spin transfer torque. Because spin waves provide a well-defined system for performing spin transfer, we anticipate that they could be used as an accurate probe of spin-polarized transport in various itinerant ferromagnets.

  8. Geometric doppler effect: spin-split dispersion of thermal radiation.

    PubMed

    Dahan, Nir; Gorodetski, Yuri; Frischwasser, Kobi; Kleiner, Vladimir; Hasman, Erez

    2010-09-24

    A geometric Doppler effect manifested by a spin-split dispersion relation of thermal radiation is observed. A spin-dependent dispersion splitting was obtained in a structure consisting of a coupled thermal antenna array. The effect is due to a spin-orbit interaction resulting from the dynamics of the surface waves propagating along the structure whose local anisotropy axis is rotated in space. The observation of the spin-symmetry breaking in thermal radiation may be utilized for manipulation of spontaneous or stimulated emission.

  9. Laser Doppler Vibrometry measurement of the mechanical myogram

    NASA Astrophysics Data System (ADS)

    Rohrbaugh, John W.; Sirevaag, Erik J.; Richter, Edward J.

    2012-06-01

    Contracting muscles show complex dimensional changes that include lateral expansion. Because this expansion process is intrinsically vibrational, driven by repetitive actions of multiple motor units, it can be sensed and quantified using the method of Laser Doppler Vibrometry (LDV). LDV has a number of advantages over more traditional mechanical methods based on microphones and accelerometers. The LDV mechanical myogram from a small hand muscle was shown under conditions of elastic loading to be related systematically to the level of force production, and to compare favorably with conventional methods for sensing the mechanical and electrical aspects of muscle contraction.

  10. A pilot study to Doppler-image an accretion spot

    NASA Astrophysics Data System (ADS)

    Moritz Guenther, Hans

    2009-10-01

    Classical T Tauri stars (CTTS) are young, accreting systems. The accretion is thought to cause a soft X-ray excess and unusual line ratios in the He-like triplets. The accretion spots can also be seen with optical Doppler-imaging; however, the final test to correlate these signatures - simultaneous X-ray and ground-based observations - is still missing. We propose a 15 ks pilot study of MN Lup, the prime target for simultaneous observations from the optical point of view, to confirm its CTTS status and characterize its X-ray properties.

  11. System for Processing Coded OFDM Under Doppler and Fading

    NASA Technical Reports Server (NTRS)

    Tsou, Haiping; Darden, Scott; Lee, Dennis; Yan, Tsun-Yee

    2005-01-01

    An advanced communication system has been proposed for transmitting and receiving coded digital data conveyed as a form of quadrature amplitude modulation (QAM) on orthogonal frequency-division multiplexing (OFDM) signals in the presence of such adverse propagation-channel effects as large dynamic Doppler shifts and frequency-selective multipath fading. Such adverse channel effects are typical of data communications between mobile units or between mobile and stationary units (e.g., telemetric transmissions from aircraft to ground stations). The proposed system incorporates novel signal processing techniques intended to reduce the losses associated with adverse channel effects while maintaining compatibility with the high-speed physical layer specifications defined for wireless local area networks (LANs) as the standard 802.11a of the Institute of Electrical and Electronics Engineers (IEEE 802.11a). OFDM is a multi-carrier modulation technique that is widely used for wireless transmission of data in LANs and in metropolitan area networks (MANs). OFDM has been adopted in IEEE 802.11a and some other industry standards because it affords robust performance under frequency-selective fading. However, its intrinsic frequency-diversity feature is highly sensitive to synchronization errors; this sensitivity poses a challenge to preserve coherence between the component subcarriers of an OFDM system in order to avoid intercarrier interference in the presence of large dynamic Doppler shifts as well as frequency-selective fading. As a result, heretofore, the use of OFDM has been limited primarily to applications involving small or zero Doppler shifts. The proposed system includes a digital coherent OFDM communication system that would utilize enhanced 802.1la-compatible signal-processing algorithms to overcome effects of frequency-selective fading and large dynamic Doppler shifts. The overall transceiver design would implement a two-frequency-channel architecture (see figure

  12. Precise Doppler tracking from the Medicina VLBI station

    NASA Astrophysics Data System (ADS)

    Ambrosini, R.; Comoretto, G.; Iess, L.; Messeri, A.

    1992-06-01

    The first opposition test of Doppler tracking the Ulysses spacecraft from the Medicina VLBI (Very Long Base Interferometry) station (Italy) proved its capability to perform a systematic search for gravitational waves. In house and JPL (Jet Propulsion Laboratory) data analysis showed that the target Allan variance of 3 x 10(exp -14) at 1000 s, planned for the DSN antennas was also achieved from the station. The main observation campaign during the second opposition phase will last for thirty continuous nights--from mid Feb. to mid Mar. 1992. The main hardware and software features developed for this application, together with some results of the first opposition test, are described.

  13. Hardening Doppler Global Velocimetry Systems for Large Wind Tunnel Applications

    NASA Technical Reports Server (NTRS)

    Meyers, James F.; Lee, Joseph W.; Fletcher, Mark T.; South, Bruce W.

    2004-01-01

    The development of Doppler Global Velocimetry from a laboratory curiosity to a wind tunnel instrumentation system is discussed. This development includes system advancements from a single velocity component to simultaneous three components, and from a steady state to instantaneous measurement. Improvements to system control and stability are discussed along with solutions to real world problems encountered in the wind tunnel. This on-going development program follows the cyclic evolution of understanding the physics of the technology, development of solutions, laboratory and wind tunnel testing, and reevaluation of the physics based on the test results.

  14. A relative performance analysis of atmospheric Laser Doppler Velocimeter methods.

    NASA Technical Reports Server (NTRS)

    Farmer, W. M.; Hornkohl, J. O.; Brayton, D. B.

    1971-01-01

    Evaluation of the effectiveness of atmospheric applications of a Laser Doppler Velocimeter (LDV) at a wavelength of about 0.5 micrometer in conjunction with dual scatter LDV illuminating techniques, or at a wavelength of 10.6 micrometer with local oscillator LDV illuminating techniques. Equations and examples are given to provide a quantitative basis for LDV system selection and performance criteria in atmospheric research. The comparative study shows that specific ranges and conditions exist where performance of one of the methods is superior to that of the other. It is also pointed out that great care must be exercised in choosing system parameters that optimize a particular LDV designed for atmospheric applications.

  15. Laser Doppler anemometer measurements using nonorthogonal velocity components: error estimates.

    PubMed

    Orloff, K L; Snyder, P K

    1982-01-15

    Laser Doppler anemometers (LDAs) that are arranged to measure nonorthogonal velocity components (from which orthogonal components are computed through transformation equations) are more susceptible to calibration and sampling errors than are systems with uncoupled channels. In this paper uncertainty methods and estimation theory are used to evaluate, respectively, the systematic and statistical errors that are present when such devices are applied to the measurement of mean velocities in turbulent flows. Statistical errors are estimated for two-channel LDA data that are either correlated or uncorrelated. For uncorrelated data the directional uncertainty of the measured velocity vector is considered for applications where mean streamline patterns are desired.

  16. Multigroup Free-atom Doppler-broadening Approximation. Experiment

    SciTech Connect

    Gray, Mark Girard

    2015-11-06

    The multigroup energy Doppler-broadening approximation agrees with continuous energy Dopplerbroadening generally to within ten percent for the total cross sections of 1H, 56Fe, and 235U at 250 lanl. Although this is probably not good enough for broadening from room temperature through the entire temperature range in production use, it is better than any interpolation scheme between temperatures proposed to date, and may be good enough for extrapolation from high temperatures. The method deserves further study since additional improvements are possible.

  17. Aerosol/Cloud Measurements Using Coherent Wind Doppler Lidars

    NASA Astrophysics Data System (ADS)

    Royer, Philippe; Boquet, Matthieu; Cariou, Jean-Pierre; Sauvage, Laurent; Parmentier, Rémy

    2016-06-01

    The accurate localization and characterization of aerosol and cloud layers is crucial for climate studies (aerosol indirect effect), meteorology (Planetary Boundary Layer PBL height), site monitoring (industrial emissions, mining,…) and natural hazards (thunderstorms, volcanic eruptions). LEOSPHERE has recently developed aerosol/cloud detection and characterization on WINDCUBE long range Coherent Wind Doppler Lidars (CWDL). These new features combine wind and backscatter intensity informations (Carrier-to-Noise Ratio CNR) in order to detect (aerosol/cloud base and top, PBL height) and to characterize atmospheric structures (attenuated backscatter, depolarization ratio). For each aerosol/cloud functionality the method is described, limitations are discussed and examples are given to illustrate the performances.

  18. SIRHEN : a data reduction program for photonic Doppler velocimetry measurements.

    SciTech Connect

    Dolan, Daniel H., III; Ao, Tommy

    2010-06-01

    SIRHEN (Sandia InfraRed HEtrodyne aNalysis) is a program for reducing data from photonic Doppler velocimetry (PDV) measurements. SIRHEN uses the short-time Fourier transform method to extract velocity information. The program can be run in MATLAB (2008b or later) or as a Windows executable. This report describes the new Sandia InfraRed HEtrodyne aNalysis program (SIRHEN; pronounced 'siren') that has been developed for efficient and robust analysis of PDV data. The program was designed for easy use within Sandia's dynamic compression community.

  19. Nonmechanical axial scanning laser Doppler velocimeter with directional discrimination.

    PubMed

    Maru, Koichi; Hata, Takahiro

    2012-07-10

    An axial scanning laser Doppler velocimeter (LDV) with directional discrimination not requiring any moving mechanism in its probe is proposed. The proposed LDV utilizes frequency shift induced by acousto-optic modulators (AOMs) for discriminating the direction of velocity. The measurement position is axially scanned by changing the wavelength of the light input to the probe. The experimental result reveals that both the axial scan and the directional discrimination can be realized by using the proposed method without any moving element in the probe.

  20. Tracking an imploding cylinder with photonic Doppler velocimetry.

    PubMed

    Dolan, D H; Lemke, R W; McBride, R D; Martin, M R; Harding, E; Dalton, D G; Blue, B E; Walker, S S

    2013-05-01

    Cylindrical implosion offers a path to extreme material states, reaching considerably higher pressures than planar geometry. However, diagnosing compressed material in cylindrical geometry is challenging. Time-resolved velocimetry, a standard technique in planar compression, is difficult to incorporate into cylindrical experiments. This paper describes the use of photonic Doppler velocimetry (PDV) in magnetically driven cylindrical compression experiments at the Sandia Z machine. With this diagnostic, it is possible to track the interior of an imploding cylinder beyond 20 km/s. A "leapfrog" implementation is described to support velocities well above the bandwidth limits of standard PDV measurements.

  1. Saturn's Doppler velocimetry wind measurements with VLT/UVES

    NASA Astrophysics Data System (ADS)

    Silva, Miguel; Mota Machado, Pedro; Luz, David; Sanchez-Lavega, Agustin; Hueso, Ricardo; Peralta, Javier

    2016-10-01

    We present Doppler wind velocity results of Saturn's zonal flow at ~0.4 mbar pressure level. Our aim is help to constrain the characterization of the equatorial jet at the referred altitude and the latitudinal variation of the zonal winds, to contribute to monitor the spatial and temporal variability in order to achieve a better understanding of the dynamics of Saturn's zonal winds, which Sánchez-Lavega et al. (2003, Nature, 423, 623) have found to have strongly changed in recent years, as the planet approached southern summer solstice.The UVES/VLT instrument has been used, which simultaneously achieves high spectral resolving power and high spatial resolution. The field has been derotated in order to have the aperture aligned perpendicularly to Saturn's rotation axis. In this configuration, spatial information in the East-West direction is preserved in a set of spectra in the direction perpendicular to dispersion.The technique of absolute accelerometry (AA, Connes, 1985, ApSS 110, 211) has been applied to the backscattered solar spectrum in order to determine the Doppler shift associated with the zonal circulation. Our measurements have been made in the wavelength range of 480-680 nm. Previously we successfully adapted this Doppler velocimetry technique for measuring winds at Venus cloud tops (Machado et al. 2012).The observations consisted of 4 blocks of 15 exposures of 90 sec, plus two shorter blocks of 9 exposures, totalling 7.3 hours of telescope time. In order to cover the whole disk the aperture has been offset by 1 arcsec in the North-South direction between consecutive exposures. Most of the northern hemisphere was covered by the rings. Saturn's diameter was 17.4 arcsec, and the slit aperture was 0.3x25 arcsec. The aperture offset between consecutive exposures was 1 arcsec. Two observations blocks of 9 exposures only covered the central part of the disk, and four others covered the whole disk. The sub-terrestrial point was at -26.1 degrees South. The

  2. NASA airborne Doppler lidar program: Data characteristics of 1981

    NASA Technical Reports Server (NTRS)

    Lee, R. W.

    1982-01-01

    The first flights of the NASA/Marshall airborne CO2 Doppler lidar wind measuring system were made during the summer of 1981. Successful measurements of two-dimensional flow fields were made to ranges of 15 km from the aircraft track. The characteristics of the data obtained are examined. A study of various artifacts introduced into the data set by incomplete compensation for aircraft dynamics is summarized. Most of these artifacts can be corrected by post processing, which reduces velocity errors in the reconstructed flow field to remarkably low levels.

  3. Compact laser Doppler flowmeter for application in dentistry

    NASA Astrophysics Data System (ADS)

    Fedosov, Ivan V.; Mareew, Gleb O.; Finokhina, Olga A.; Lepilin, Alexander V.; Tuchin, Valery V.

    2005-06-01

    Lightweight handheld laser Doppler instrument is designed for blood flow assessment in soft tissues of oral cavity. Laser light source, fiber optic probe detector and amplifier circuitry are mounted inside the compact hand held probe assembly to minimize noise and to exclude optical fiber motion artifacts. Both the instrument and data processing software are optimized for the using of the standard PC sound interface as the data acquisition device that provides low cost and effective solution for clinical use. The instrument is suitable for quantitative diagnostics of gingivitis and other disorders in dentistry.

  4. Turbulent transport measurements with a laser Doppler velocimeter

    NASA Technical Reports Server (NTRS)

    Edwards, R. V.; Angus, J. C.; Dunning, J. W., Jr.

    1972-01-01

    The power spectrum of phototube current from a laser Doppler velocimeter operating in the heterodyne mode has been computed. The spectrum is obtained in terms of the space time correlation function of the fluid. The spectral width and shape predicted by the theory are in agreement with experiment. For normal operating parameters the time average spectrum contains information only for times shorter than the Lagrangian integral time scale of the turbulence. To examine the long time behavior, one must use either extremely small scattering angles, much longer wavelength radiation or a different mode of signal analysis, e.g., FM detection.

  5. Quality assurance in laser-Doppler flowmetry applied to dentistry

    NASA Astrophysics Data System (ADS)

    Kaulich, Theodor W.; Koerber, Erich

    1996-12-01

    Laser-doppler flowmetry (LDF) is a diagnostic method for checking and judging vitality in tissues. In dentistry, with the help of LDF, there can be investigated short-term or long-term changes of the oral microcirculation. Defects in the LDF equipment which go undiscovered lead to changes in the quality of the biosignals and hamper diagnosis. Reliable and reproducible results are only obtained if the LDF equipment concerned there exists a standardized quality assurance program. There has been developed and tested a method for constancy checks in LDF measurements. The investigation shows that before each clinical application of an LDF equipment careful testing is necessary.

  6. Rotational Doppler effect in harmonic generation from spinning molecules

    NASA Astrophysics Data System (ADS)

    Faucher, O.; Prost, E.; Hertz, E.; Billard, F.; Lavorel, B.; Milner, Alexander A.; Milner, Valery A.; Zyss, Joseph; Averbukh, Ilya Sh.

    2016-11-01

    We present an observation of the rotational Doppler shift in the frequency of optical harmonic generated in fast rotating molecules. Conservation of energy and angular momentum in the light-molecule interaction suggests four different kinds of shifts depending on the mutual handedness of the circularly polarized fundamental and harmonic fields, as well as the handedness of the molecular rotation. All four types of the frequency shifts were observed in our experiments on third-harmonic generation in a gas of fast spinning O2 molecules.

  7. Clutter Rejection for Doppler Weather Radars with Multirate Sampling Schemes

    DTIC Science & Technology

    1990-12-11

    L > 0 02 0 j z uj>cq r LL) M:5ul -j CD <> . t<> t cc 0 0 uj m I.- CL CL ri) CL LU CL U) u S .) cc cr <m > Ij’ I I m 1-20 0 0 6 04 LU wm 0 wcc cc0...Zrni6, Doppler Radar and Weather Observations, Academic Press, New York, 1984. Evans83a. J.E. Evans, "Ground Clutter Cancellation for the NEXRAD System...Witt87a. A. Witt and S.D. Smith, Development and Testing of the Gust Front Algo- rithm, NOAA Environmental Research Laboratories, National Severe Storms

  8. Structural damage assessment in composite material using laser Doppler vibrometry

    NASA Astrophysics Data System (ADS)

    Willemann, Daniel P.; Castellini, Paolo; Revel, Gian M.; Tomasini, Enrico P.

    2004-06-01

    In recent years, a great effort has been done to improve damage detection techniques in structures by using vibration measurements. This paper presents a case where a non-contact measurement system, a Scanning Laser Doppler Vibrometer, has been used to detect delaminations in a composite material plate. The diagnostic technique is the evolution of a methodology previously approached by the authors. An in-house made software has been produced for data acquisition and vibrometer control. The maps of the detected defects are presented, thus allowing the assessment of the performances of this methodology to detect damages. This analysis permitted to outline the main points to be improved in the future investigations.

  9. Dynamic characteristics of laser-Doppler flux data.

    PubMed

    Popivanov, D; Mineva, A; Dushanova, J

    1999-01-01

    Methods for tracking the dynamics of the blood flow microcirculation obtained by laser-Doppler flowmetry (LDF) technique are described. It was shown that LDF signals have complex dynamics. It was mainly characterized by fractal structures and chaos, though multiperiodic, trend-like and stochastic components were also established. Procedures for (i) describing the dynamic structure and (ii) tracking the dynamic changes in time of LDF data are proposed. Examples illustrating the efficiency of these procedures are given using both simulated and LDF data collected in experiments with reactive hyperemia. Irrespective of the universality of the methods, the procedures should be specified according to the problem-oriented clinical and experimental studies.

  10. Doppler measurements of an interplanetary satellite with a VLBI antenna

    NASA Technical Reports Server (NTRS)

    Gomoretto, G.; Iess, L.; Bertotti, Bruno; Grueff, G.; Brenkle, I. B.; Horton, A.

    1989-01-01

    In preparation for the Ulysses Gravitational Wave Experiment a Doppler detector has been constructed for the Bologna VLBI antenna and tested in a differential mode with the spacecraft Voyager 2 at 25 AU. In this mode the signal was sent from the Deep Space Network station in Canberra and received at Madrid and Bologna. The correlation between the received signals allows a discrimination between local and common noise sources. The successful test was performed in August, 1988 showed that special communication procedure will have to be implemented to allow a smooth and reliable operation during the real experiment.

  11. Continuous cardiac output measurement - Aspects of Doppler frequency analysis

    NASA Technical Reports Server (NTRS)

    Mackay, R. S.; Hechtman, H. B.

    1975-01-01

    From the suprasternal notch blood flow velocity in the aorta can be measured non-invasively by a Doppler probe. Integration over systole after frequency analysis gives a measure of stroke volume if a separate diameter observation is incorporated. Frequency analysis by a zero crossing counter or by a set of parallel phaselock loops was less effective than a set of bandpass filters. Observations on dogs, baboons and humans before and after exercise or surgery suggest the indications to be useful. Application to judging heart failure by the effect of introducing a volume load is indicated. Changes in output also are measured in freely moving subjects.

  12. Improved Prediction of the Doppler Effect in TRISO Fuel

    SciTech Connect

    J. Ortensi; A.M. Ougouag

    2009-05-01

    The Doppler feedback mechanism is a major contributor to the passive safety of gas-cooled, graphite-moderated High Temperature Reactors that use fuel based on TRISO particles. It follows that the correct prediction of the magnitude and time-dependence of this feedback effect is essential to the conduct of safety analyses for these reactors. Since the effect is directly dependent on the actual temperature reached by the fuel during transients, the underlying phenomena of heat transfer and temperature rise must be correctly predicted. This paper presents an improved model for the TRISO particle and its thermal behavior during transients. The improved approach incorporates an explicit TRISO heat conduction model to better quantify the time dependence of the temperature in the various layers of the TRISO particle, including its fuel central zone. There follows a better treatment of the Doppler Effect within said fuel zone. The new model is based on a 1-D analytic solution for composite media using the Green’s function technique. The modeling improvement takes advantage of some of the physical behavior of TRISO fuel under irradiation and includes a distinctive look at the physics of the neutronic Doppler Effect. The new methodology has been implemented within the coupled R-Z nodal diffusion code CYNOD-THERMIX. The new model has been applied to the analysis of earthquakes (presented in a companion paper). In this paper, the model is applied to the control rod ejection event, as specified in the OECD PBMR-400 benchmark, but with temperature dependent thermal properties. The results obtained for this transient using the enhanced code are a considerable improvement over the predictions of the original code. The incorporation of the enhanced model shows that the Doppler Effect plays a more significant role than predicted by the original unenhanced model based on the THERMIX homogenized fuel region model. The new model shows that the overall energy generation during the rod

  13. Radial pump impeller measurements using a laser Doppler velocimeter

    NASA Astrophysics Data System (ADS)

    Kannemans, H.

    1980-03-01

    A shrouded fully transparent radial pump impeller with thin backswept blades has been tested using a laser Doppler velocimeter. Two components of the velocity were measured relative to the laboratory reference frame in a plane perpendicular to the axis of rotation. The velocity distribution is presented relative to the blades at different radii and different flow rates over the whole blade passage. The results show that the flow is essentially unsteady and, at low flow rate, highly influenced by viscous effects. A comparison between the experimental data and a potential flow theory shows good agreement at high flow rates.

  14. Corruption of radio metric Doppler due to solar plasma dynamics: S/X dual-frequency Doppler calibration for these effects

    NASA Technical Reports Server (NTRS)

    Winn, F. B.; Reinbold, S. R.; Yip, K. W.; Koch, R. E.; Lubeley, A.

    1975-01-01

    Doppler data from Mariner 6, 7, 9, and 10 and Pioneer 10 and 11 were discussed and the rms noise level for various sun-earth-probe angles were shown. The noise levels of both S- and X-band Doppler data for sun-earth-probe angles smaller than 20 deg were observed to be orders of magnitude greater than nominal. Such solar plasma-related Doppler degradation reduced the Mariner 10-Mercury 11 encounter navigation accuracy by nearly a factor of 10. Furthermore, this degradation was shown to be indirectly related to plasma dynamics and not a direct measure of the dynamics.

  15. Least-Squares Multi-Angle Doppler Estimators for Plane Wave Vector Flow Imaging.

    PubMed

    Yiu, Billy Y S; Yu, Alfred C H

    2016-06-20

    Designing robust Doppler vector estimation strategies for use in plane wave imaging schemes based on unfocused transmissions is a topic that has yet to be studied in depth. One potential solution is to use a multi-angle Doppler estimation approach that computes flow vectors via least-squares fitting, but its performance has not been established. Here, we investigated the efficacy of multi-angle Doppler vector estimators by: (i) comparing its performance with respect to the classical dual-angle (cross-beam) Doppler vector estimator; (ii) examining the working effects of multi-angle Doppler vector estimators on flow visualization quality in the context of dynamic flow path rendering. Implementing Doppler vector estimators that use different combinations of transmit (Tx) and receive (Rx) steering angles, our analysis has compared the classical dual-angle Doppler method, a 5-Tx version of dual-angle Doppler, and various multi-angle Doppler configurations based on 3 Tx and 5 Tx. Two angle spans (10°, 20°) were examined in forming the steering angles. In imaging scenarios with known flow profiles (rotating disc and straight-tube parabolic flow), the 3-Tx, 3-Rx and 5-Tx, 5-Rx multi-angle configurations produced vector estimates with smaller variability comparing to the dual-angle method, and the estimation results were more consistent with the use of a 20° angle span. Flow vectors derived from multi-angle Doppler estimators were also found to be effective in rendering the expected flow paths in both rotating disc and straight-tube imaging scenarios, while the ones derived from the dual-angle estimator yielded flow paths that deviated from the expected course. These results serve to attest that, using multi-angle least-squares Doppler vector estimators, flow visualization can be consistently achieved.

  16. Least-Squares Multi-Angle Doppler Estimators for Plane-Wave Vector Flow Imaging.

    PubMed

    Yiu, Billy Y S; Yu, Alfred C H

    2016-11-01

    Designing robust Doppler vector estimation strategies for use in plane-wave imaging schemes based on unfocused transmissions is a topic that has yet to be studied in depth. One potential solution is to use a multi-angle Doppler estimation approach that computes flow vectors via least-squares fitting, but its performance has not been established. Here, we investigated the efficacy of multi-angle Doppler vector estimators by: 1) comparing its performance with respect to the classical dual-angle (cross-beam) Doppler vector estimator and 2) examining the working effects of multi-angle Doppler vector estimators on flow visualization quality in the context of dynamic flow path rendering. Implementing Doppler vector estimators that use different combinations of transmit (Tx) and receive (Rx) steering angles, our analysis has compared the classical dual-angle Doppler method, a 5-Tx version of dual-angle Doppler, and various multi-angle Doppler configurations based on 3 Tx and 5 Tx. Two angle spans (10°, 20°) were examined in forming the steering angles. In imaging scenarios with known flow profiles (rotating disk and straight-tube parabolic flow), the 3-Tx, 3-Rx and 5-Tx, 5-Rx multi-angle configurations produced vector estimates with smaller variability compared with the dual-angle method, and the estimation results were more consistent with the use of a 20° angle span. Flow vectors derived from multi-angle Doppler estimators were also found to be effective in rendering the expected flow paths in both rotating disk and straight-tube imaging scenarios, while the ones derived from the dual-angle estimator yielded flow paths that deviated from the expected course. These results serve to attest that using multi-angle least-squares Doppler vector estimators, flow visualization can be consistently achieved.

  17. [Tissue Doppler: the physical principles, representational and analytical modalities and clinical applications].

    PubMed

    Trambaiolo, P; Salustri, A; Tonti, G; Fedele, F; Palamara, A

    2000-01-01

    Tissue Doppler imaging or myocardial velocity imaging is a variation of conventional Doppler. This modality allows the quantification of the Doppler shift within the range of myocardial tissue motion. The velocity of motion at a variety of myocardial sites can be determined and distinguished very rapidly using Doppler techniques. The velocity of moving tissue can be studied with pulsed wave tissue Doppler sampling, which displays the velocity of a selected myocardial region against time, with high temporal resolution. In addition, the velocities can be calculated with time velocity maps and displayed as color coded velocity maps in either M-mode or two-dimensional format. This review will focus on the technical aspects and the different methods of tissue Doppler for regional systolic and diastolic left ventricular function analysis. While pulsed wave tissue Doppler allows us to measure the velocities of a selected myocardial region, color tissue Doppler gives the best overall view of cardiac dynamics because the whole scanned color data are displayed simultaneously. However, there is an increasing need for objective evaluation of tissue Doppler information. Digital images and data post-processing allow for quantitative off-line analysis, and the different approaches and parameters proposed from different centers are discussed. In recent years, tissue Doppler imaging has been applied for accurate evaluation of diastolic function, quantifying regional function particularly during stress, pre-excitation syndrome, and left ventricular hypertrophy. The results of these experiences indicate that tissue Doppler imaging is a promising technique for quantifying the response of the myocardium and endocardium during both normal and abnormal function. Again, there is a significant learning curve concerning its application, but with experience it will be a useful and reproducible technique.

  18. Doppler effects on velocity spectra observed by MST radars

    NASA Technical Reports Server (NTRS)

    Scheffler, A. O.; Liu, C. H.

    1986-01-01

    Recently, wind data from mesophere-stratosphere-troposphere (MST) radars have been used to study the spectra of gravity waves in the atmosphere (Scheffler and Liu, 1985; VanZandt et al., 1985). Since MST radar measures the line-of-sight Doppler velocities, it senses the components of the wave-associated velocities along its beam directions. These components are related through the polarization relations which depend on the frequency and wave number of the wave. Therfore, the radar-observed velocity spectrum will be different from the original gravity-wave spectrum. Their relationship depends on the frequency and wave number of the wave as well as the propagation geometry. This relation can be used to interpret the observed data. It can also be used to test the assumption of gravity-wave spectrum (Scheffler and Liu, 1985). In deriving this relation, the background atmosphere has been assumed to be motionless. Obviously, the Doppler shift due to the background wind will change the shape of the gravity-wave power spectrum as well as its relation with the radar-observed spectrum. Here, researcher's investigate these changes.

  19. Multiplexed photonic Doppler velocimetry for large channel count experiments

    NASA Astrophysics Data System (ADS)

    Daykin, Edward; Burk, Martin; Holtkamp, David; Miller, Edward Kirk; Rutkowski, Araceli; Strand, Oliver Ted; Pena, Michael; Perez, Carlos; Gallegos, Cenobio

    2017-01-01

    Photonic Doppler Velocimetry (PDV) is routinely employed as a means of measuring surface velocities for shockwave experimentation. Scientists typically collect ˜4 to 12 channels of PDV data and use extrapolation, assumptions, and models to determine the velocities in regions of the experiment that were not observed directly. We have designed, built and applied a new optical velocimetry diagnostic—the Multiplexed Photonic Doppler Velocimeter (MPDV)—for use on shock physics experiments that require a large number (100s) of spatial points to be measured. MPDV expands upon PDV measurement capabilities via frequency and time multiplexing using commercially available products developed for the telecommunications industry. The MPDV uses the heterodyne method to multiplex four data channels in the frequency domain combined with fiber delays to multiplex an additional four-channel dataset in the time domain, all of which are recorded onto the same digitizer input. This means that each digitizer input records data from eight separate spatial points, so that a single 4-input digitizer may record a total of 32 channels of data. Motivation for development of a multiplexed PDV was driven by requirements for an economical, high-fidelity, high channel-count optical velocimetry system. We present a survey of the methods, components, and trade-offs incorporated into this recent development in optical velocimetry.

  20. Users Guide to the JPL Doppler Gravity Database

    NASA Technical Reports Server (NTRS)

    Muller, P. M.; Sjogren, W. L.

    1986-01-01

    Local gravity accelerations and gravimetry have been determined directly from spacecraft Doppler tracking data near the Moon and various planets by the Jet Propulsion Laboratory. Researchers in many fields have an interest in planet-wide global gravimetric mapping and its applications. Many of them use their own computers in support of their studies and would benefit from being able to directly manipulate these gravity data for inclusion in their own modeling computations. Pubication of some 150 Apollo 15 subsatellite low-altitude, high-resolution, single-orbit data sets is covered. The doppler residuals with a determination of the derivative function providing line-of-sight-gravity are both listed and plotted (on microfilm), and can be ordered in computer readable forms (tape and floppy disk). The form and format of this database as well as the methods of data reduction are explained and referenced. A skeleton computer program is provided which can be modified to support re-reductions and re-formatted presentations suitable to a wide variety of research needs undertaken on mainframe or PC class microcomputers.

  1. Velocity magnitude estimation with linear arrays using Doppler bandwidth.

    PubMed

    Tortoli, P; Guidi, G; Mantovani, L; Newhouse, V L

    2001-04-01

    The dependence of pulsed wave Doppler bandwidth on parameters typical of linear transducer arrays used in commercial Duplex and color flow mapping systems is investigated experimentally. For a single flow line it is observed that this bandwidth generally depends not only on the scatterer velocity and the beam-to-flow angle, but also on the flow line range and orientation. This is due to the fact that in Duplex and color flow systems the transducer is differently focused in the scan and elevation planes and its aperture and focal lengths are often made to vary, depending on the distance of the flow line from the transducer. It is however experimentally demonstrated that, at points where the ultrasound beamwidths in the scan and elevation planes are both comparable to the sample volume length, the Doppler bandwidth is independent of the beam-to-flow angle. It is also shown that this invariance can be extended to other ranges by appropriately modifying the array aperture. Finally, as an application of this independence, the flow-line velocity magnitude in these beam regions is estimated with better than 5% uncertainty through a simple bandwidth measurement.

  2. A fisheye lens as a photonic Doppler velocimetry probe

    NASA Astrophysics Data System (ADS)

    Frogget, Brent C.; Cata, Brian M.; Cox, Brian C.; DeVore, Douglas O.; Esquibel, David L.; Frayer, Daniel K.; Furlanetto, Michael R.; Holtkamp, David B.; Kaufman, Morris I.; Malone, Robert M.; Romero, Vincent T.

    A new fisheye lens design is used as a miniature probe to measure the velocity distribution of an imploding surface along many lines of sight. Laser light, directed and scattered back along each beam on the surface, is Doppler shifted by the moving surface and collected into the launching fiber. The received light is mixed with reference laser light in each optical fiber in a technique called photonic Doppler velocimetry, providing a continuous time record. An array of single-mode optical fibers sends laser light through the fisheye lens. The lens consists of an index-matching positive element, two positive doublet groups, and two negative singlet elements. The optical design minimizes beam diameters, physical size, and back reflections for excellent signal collection. The fiber array projected through the fisheye lens provides many measurement points of surface coverage over a hemisphere with very little crosstalk. The probe measures surface movement with only a small encroachment into the center of the cavity. The fiber array is coupled to the index-matching element using index-matching gel. The array is bonded and sealed into a blast tube for ease of assembly and focusing. This configuration also allows the fiber array to be flat polished at a common object plane. In areas where increased measurement point density is desired, the fibers can be close packed. To further increase surface density coverage, smaller-diameter cladding optical fibers may be used.

  3. Evaluation of data obtained from atmospheric laser Doppler velocimeter

    NASA Technical Reports Server (NTRS)

    Keck, T. S.; Telford, J. W.

    1985-01-01

    The Doppler lidar velocimeter produces a variety of kinds of data. Besides the line of sight velocity components, there are the reflected amplitudes and the Doppler widths. Computer graphics software for displaying these data was produced. Different methods of presentation are needed for the various items. A picture was produced as pictures are often the best way to gain understanding. The individual lidar scans form a crosshatch pattern. Thus one-dimensional measurements fit together to form a two-dimensional whole. A pair of velocity measurements at a point combine to form a wind measurement with direction and magnitude. This gives a forest of wind vectors. The goal is to find a recognizable pattern to these trees. Often it is necessary to show only part of the information. That is, show only the wind direction not its magnitude or reduce the wind to streamlines of air flow. In other cases data are reduced to contour plots. Just enough contour lines are included to show the picture described.

  4. Evaluation of gingival vascularisation using laser Doppler flowmetry

    NASA Astrophysics Data System (ADS)

    Vitez, B.; Todea, C.; Velescu, A.; Şipoş, C.

    2016-03-01

    Aim: The present study aims to assess the level of vascularisation of the lower frontal gingiva of smoker patients, in comparison with non-smokers by using Laser Doppler Flowmetry (LDF), in order to determine the changes in gingival microcirculation. Material & methods: 16 volunteers were included in this study and separated into 2 equal groups: non-smoker subjects in Group I and smoker subjects in Group II. All patients were submitted to a visual examination and professional cleaning The gingival bloodflow of each patient was recorded in 5 zones using LDF, resulting in a total of 80 recordings. LDF was done with the Moor Instruments Ltd. "moorLAB" Laser Doppler. All data were collected as graphs, raw values and statistically analyzed. Results: After strict analysis results show that Group II presents a steady level of gingival microcirculation with even patterns in the graph, while Group I shows many signs of damage to it`s microvascular system through many irregularities in the microcirculation level and graph patterns. Conclusion: The results suggest that prolonged smoking has a definitive effect on the gingival vascularisation making it a key factor in periodontal pathology.

  5. Design, Assembly, and Testing of a Photon Doppler Velocimetry Probe

    SciTech Connect

    Malone, Robert M; Cox, Brian C; Daykin, Edward P; DeVore, Douglas O; Esquibel, David L; Frayer, Daniel K; Frogget, Brent C; Gallegos, Cenobio H; Kaufman, Morris I; McGillivray, Kevin D; Romero, Vincent T; Briggs, Matthew E; Furlanetto, Michael R; Holtkamp, David B; Pazuchanics, Peter; Primas, Lori E; Shinas, Michael A; Sorenson, Danny S

    2011-08-21

    A novel fiber-optic probe measures the velocity distribution of an imploding surface along many lines of sight. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called photon Doppler velocimetry, providing continuous time records. Within the probe, a matrix array of 56 single-mode fibers sends light through an optical relay consisting of three types of lenses. Seven sets of these relay lenses are grouped into a close-packed array allowing the interrogation of seven regions of interest. A six-faceted prism with a hole drilled into its center directs the light beams to the different regions. Several types of relay lens systems have been evaluated, including doublets and molded aspheric singlets. The optical design minimizes beam diameters and also provides excellent imaging capabilities. One of the fiber matrix arrays can be replaced by an imaging coherent bundle. This close-packed array of seven relay systems provides up to 476 beam trajectories. The pyramid prism has its six facets polished at two different angles that will vary the density of surface point coverage. Fibers in the matrix arrays are angle polished at 8{sup o} to minimize back reflections. This causes the minimum beam waist to vary along different trajectories. Precision metrology on the direction cosine trajectories is measured to satisfy environmental requirements for vibration and temperature.

  6. Color-flow Doppler sonography in Graves disease: "thyroid inferno".

    PubMed

    Ralls, P W; Mayekawa, D S; Lee, K P; Colletti, P M; Radin, D R; Boswell, W D; Halls, J M

    1988-04-01

    Graves disease is a common diffuse abnormality of the thyroid gland usually characterized by thyrotoxicosis. We performed color-flow Doppler sonography in 16 patients with Graves disease and compared the results with those in 15 normal volunteers and 14 patients with other thyroid diseases (eight with multinodular goiter, four with focal masses, and two with papillary thyroid carcinoma). All 16 Graves disease patients exhibited a pulsatile pattern we call "thyroid inferno." This pattern consists of multiple small areas of intrathyroidal flow seen diffusely throughout the gland in both systole and diastole. In systole, both high-velocity flow (color coded white) and lower velocity flow (color coded red and blue) were noted. In diastole, fewer areas of flow and lower velocity flow were noted. Patients with Graves disease also exhibited color flow around the periphery of the gland. The inferno pattern did not occur in normal subjects or in patients with other thyroid diseases. On occasion, focal areas of intrathyroidal flow were detected in patients with multinodular goiter and focal thyroid masses. High-resolution gray-scale images did not show the small vascular channels from which the flow signal originated. Color-flow Doppler sonography shows promise as a cost-effective, noninvasive technique for diagnosing Graves disease.

  7. A Fisheye Lens as a Photonic Doppler Velocimetry Probe

    SciTech Connect

    Frogget, B C; Cox, B C; DeVore, D O; Esquibel, D L; Frayer, D K; Furlanetto, M R; Holtkamp, D B; Kaufman, M I; Malone, R M; Romero, V T

    2012-09-01

    A new fisheye lens design is used as a miniature probe to measure the velocity distribution of an imploding surface along many lines of sight. Laser light, directed and scattered back along each beam on the surface, is Doppler shifted by the moving surface and collected into the launching fiber. The received light is mixed with reference laser light in each optical fiber in a technique called photonic Doppler velocimetry, providing a continuous time record. An array of single-mode optical fibers sends laser light through the fisheye lens. The lens consists of an index-matching positive element, two positive doublet groups, and two negative singlet elements. The optical design minimizes beam diameters, physical size, and back reflections for excellent signal collection. The fiber array projected through the fisheye lens provides many measurement points of surface coverage over a hemisphere with very little crosstalk. The probe measures surface movement with only a small encroachment into the center of the cavity. The fiber array is coupled to the index-matching element using index-matching gel. The array is bonded and sealed into a blast tube for ease of assembly and focusing. This configuration also allows the fiber array to be flat polished at a common object plane. In areas where increased measurement point density is desired, the fibers can be close packed. To further increase surface density coverage, smaller-diameter cladding optical fibers may be used.

  8. Multiplexed Photonic Doppler Velocimetry for Large Channel Count Experiments

    NASA Astrophysics Data System (ADS)

    Daykin, Edward; Burk, Martin; Gallegos, Cenobio; Pena, Michael; Perez, Carlos; Rutkowski, Araceli; Strand, Oliver; Holtkamp, David

    2015-06-01

    The Photonic Doppler Velocimeter (PDV) is routinely employed as a means of measuring surface velocities for shockwave experimentation. Scientists typically collect ~ 4 to 12 channels of PDV data and use extrapolation, assumptions and models to determine the velocities in regions of the experiment that were not observed directly. We have designed, built and applied a new optical velocimetry diagnostic - the Multiplexed Photonic Doppler Velocimeter (MPDV) - for use on shock physics experiments that requires a large number (~ 100) of spatial points to be measured. MPDV expands upon PDV measurement capabilities via frequency and time multiplexing. The MPDV is built using commercially available products. The MPDV uses the heterodyne method to multiplex four data channels in the frequency domain combined with fiber delays to multiplex an additional four channel data set in the time domain, all of which are recorded onto the same digitizer input. This means that each digitizer input records data from eight separate spatial points, so that a single 4-input digitizer may record a total of 32 channels of data. Motivation for development of a multiplexed PDV was driven by requirements for an economical, high channel count optical velocimetry system. We will present a survey of methods, components and trade-offs incorporated into this recent development in optical velocimetry.

  9. Doppler lidar observations of plume dynamics from large wildfires

    NASA Astrophysics Data System (ADS)

    Lareau, N.; Clements, C. B.

    2014-12-01

    Novel Doppler lidar observations of smoke plumes from large wildfires are made from a mobile atmospheric profiling system. Few quantitative observations exist that resolve the plume dynamics of active wildfires. Our observations elucidate three important and poorly understood aspects of convective columns: (1) column rotation, (2) penetrative convection, and (3) deep pyrocumulus clouds. Our first observational case examines vigorus anti-cyclonic rotation that occurred in a rapidly developing wildfire. The convective column was first purely convergent, then as the fire intensified, the column acquired strong (+/- 15 m s-1) anticyclonic rotation. The Doppler lidar recorded the vortex structure, strength, and evolution, including the merger of smaller vorticies into a single long-lived vortex. The second case examines the interaction of the convective plumes with shear layers and capping stable layers. These data show explosive convective growth as fire-induced buoyancy penetrated into the free troposphere. Observations of entrainment into the plumes is expecitly resolved in the lidar scans. The final case examines rarely observed deep pyrocumulus clouds associated with an intense forest fire. The lidar data reveal plume structure, including t the height of the lifted condensation level and the full height of the plume top which was in excess of 8 km AGL.

  10. On-Orbit Ephemeris Determination with Radio Doppler Validation

    SciTech Connect

    Dallmann, Nicholas; Proicou, Michael Chris; Seitz, Daniel Nathan; Warniment, Adam

    2016-02-09

    Multiple CubeSats are often released from the same host spacecraft into virtually the same orbit at nearly the same time. A satellite team needs the ability to identify and track its own satellites as soon as possible. However, this can be a difficult and confusing task with a large number of satellites. Los Alamos National Laboratory encountered this issue during a launch of LANL-designed CubeSats that were released with more than 20 other objects. A simple radio Doppler method used shortly after launch by the Los Alamos team to select its satellites of interest from the list of available tracked ephemerides is described. This method can also be used for automated real time ephemeris validation. For future efforts, each LANL-designed CubeSat will automatically perform orbit determination from the position, velocity, and covariance estimates provided by an added on-board GPS receiver. This self-determined ephemeris will be automatically downlinked by ground stations for mission planning, antenna tracking, Doppler-pre-correction, etc. A simple algorithm based on established theory and well suited for embedded on-board processing is presented. The trades examined in selecting the algorithm components and data formats are briefly discussed, as is the expected performance.

  11. Method for ambiguity resolution in range-Doppler measurements

    NASA Technical Reports Server (NTRS)

    Heymsfield, Gerald M. (Inventor); Miller, Lee S. (Inventor)

    1994-01-01

    A method for resolving range and Doppler target ambiguities when the target has substantial range or has a high relative velocity in which a first signal is generated and a second signal is also generated which is coherent with the first signal but at a slightly different frequency such that there exists a difference in frequency between these two signals of Delta f(sub t). The first and second signals are converted into a dual-frequency pulsed signal, amplified, and the dual-frequency pulsed signal is transmitted towards a target. A reflected dual-frequency signal is received from the target, amplified, and changed to an intermediate dual-frequency signal. The intermediate dual-frequency signal is amplified, with extracting of a shifted difference frequency Delta f(sub r) from the amplified intermediate dual-frequency signal done by a nonlinear detector. The final step is generating two quadrature signals from the difference frequency Delta f(sub t) and the shifted difference frequency Delta f(sub r) and processing the two quadrature signals to determine range and Doppler information of the target.

  12. Study on characteristics of chirp about Doppler wind lidar system

    NASA Astrophysics Data System (ADS)

    Du, Li-fang; Yang, Guo-tao; Wang, Ji-hong; Yue, Chuan; Chen, Lin-xiang

    2016-11-01

    In the doppler wind lidar, usually every 4MHz frequency error will produce wind error of 1m/s of 532nm laser. In the Doppler lidar system, frequency stabilization was achieved through absorption of iodine molecules. Commands that control the instrumental system were based on the PID algorithm and coded using VB language. The frequency of the seed laser was locked to iodine molecular absorption line 1109 which is close to the upper edge of the absorption range, with long-time (>4h) frequency-locking accuracy being≤0.5MHz and long-time frequency stability being 10-9 . The experimental result indicated that the seed frequency and the pulse laser frequency have a deviation, which effect is called the laser chirp characteristics. Finally chirp test system was constructed and tested the frequency offset in time. And such frequency deviation is known as Chirp of the laser pulse. The real-time measured frequency difference of the continuous and pulsed lights was about 10MHz, long-time stability deviation was around 5MHz. After experimental testing technology mature, which can monitoring the signal at long-term with corrected the wind speed.

  13. Simulated O VI Doppler dimming measurements of coronal outflow velocities

    NASA Technical Reports Server (NTRS)

    Strachan, Leonard; Gardner, L. D.; Kohl, John L.

    1992-01-01

    The possibility of determining O(5+) outflow velocities by using a Doppler dimming analysis of the resonantly scattered intensities of O VI lambda 1031.9 and lambda 1037.6 is addressed. The technique is sensitive to outflow velocities, W, in the range W greater than 30 and less than 250 km/s and can be used for probing regions of the inner solar corona, where significant coronal heating and solar wind acceleration may be occurring. These velocity measurements, when combined with measurements of other plasma parameters (temperatures and densities of ions and electrons) can be used to estimate the energy and mass flux of O(5+). In particular, it may be possible to locate where the flow changes from subsonic to supersonic and to identify source regions for the high and low speed solar wind. The velocity diagnostic technique is discussed with emphasis placed on the requirements needed for accurate outflow velocity determinations. Model determinations of outflow velocities based on simulated Doppler observations are presented.

  14. Cardiac involvement in Sydenham's chorea: clinical and Doppler echocardiographic findings.

    PubMed

    Elevli, M; Celebi, A; Tombul, T; Gökalp, A S

    1999-10-01

    Sydenham's chorea is often encountered in pure form, but it may also occur in association with carditis. Recently, it has been reported that silent, mild valvular regurgitation has been encountered in patients with rheumatic fever manifested by isolated polyarthritis and pure chorea. We studied 22 children with Sydenham's chorea to determine clinical and subclinical heart involvement at the time of the initial diagnosis. Ages of the patients ranged from 6-19 y (mean 13.14+/-3.0), and the female/male ratio was 3.4:1. All patients were evaluated by clinical and echocardiographic examination with respect to heart involvement. Carditis was detected in only 5 of 22 patients (23%) by auscultation. Clinical valvular involvement was determined: mitral regurgitation in three and combined mitral and aortic regurgitation in two. The frequency of valvular involvement increased significantly to 63% 2(14/22) after adding silent mitral regurgitation detected by colour Doppler echocardiography (chi2=7.50, p=0.0062). We found that clinically inaudible, but echocardiographically significant, mild valvular regurgitation was frequent in patients with pure chorea. It is concluded that colour Doppler echocardiography may be useful in detecting silent valvular regurgitation and in deciding the duration of prophylaxis.

  15. Digital storage and analysis of color Doppler echocardiograms

    NASA Technical Reports Server (NTRS)

    Chandra, S.; Thomas, J. D.

    1997-01-01

    Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.

  16. The first Doppler images of the eclipsing binary SZ Piscium

    NASA Astrophysics Data System (ADS)

    Xiang, Yue; Gu, Shenghong; Cameron, A. Collier; Barnes, J. R.; Zhang, Liyun

    2016-02-01

    We present the first Doppler images of the active eclipsing binary system SZ Psc, based on the high-resolution spectral data sets obtained in 2004 November and 2006 September-December. The least-squares deconvolution technique was applied to derive high signal-to-noise profiles from the observed spectra of SZ Psc. Absorption features contributed by a third component of the system were detected in the LSD profiles at all observed phases. We estimated the mass and period of the third component to be about 0.9 M⊙ and 1283 ± 10 d, respectively. After removing the contribution of the third body from the least-squares deconvolved profiles, we derived the surface maps of SZ Psc. The resulting Doppler images indicate significant star-spot activities on the surface of the K subgiant component. The distributions of star-spots are more complex than that revealed by previous photometric studies. The cooler K component exhibited pronounced high-latitude spots as well as numerous low- and intermediate-latitude spot groups during the entire observing seasons, but did not show any large, stable polar cap, different from many other active RS CVn-type binaries.

  17. Non-invasive diagnosis of mitral regurgitation by Doppler echocardiography.

    PubMed Central

    Blanchard, D; Diebold, B; Peronneau, P; Foult, J M; Nee, M; Guermonprez, J L; Maurice, P

    1981-01-01

    The value of Doppler echocardiography for the non-invasive diagnosis of mitral regurgitation was studied blindly in 161 consecutive invasively investigated adult patients. Regurgitation was graded from 0 to 3 at selective left ventricular angiography. The Doppler echocardiographic examination was considered to be positive when a disturbed systolic flow was found within the left atrium behind the aorta or the anterior leaflet of the mitral valve. The test was considered to be negative in the absence of a regurgitant jet. The level of the signal to noise ratio was checked by the recording of the ventricular filling flow. The study was performed in 131 cases from the left side of the sternum and in 101 cases from the apex. There were no false positives and thus the specificity was 100 per cent. The 20 false negatives were all in patients with grade 1 regurgitation. Thus only some (33%) instances of mild regurgitation were misdiagnosed, and the sensitivity for moderate to severe mitral regurgitation was 100 per cent. PMID:7236465

  18. Microwave and millimeter-wave Doppler radar heart sensing

    NASA Astrophysics Data System (ADS)

    Boric-Lubecke, Olga; Lin, Jenshan; Lubecke, Victor M.; Host-Madsen, Anders; Sizer, Tod

    2007-04-01

    Technology that can be used to unobtrusively detect and monitor the presence of human subjects from a distance and through barriers can be a powerful tool for meeting new security challenges, including asymmetric battlefield threats abroad and defense infrastructure needs back home. Our team is developing mobile remote sensing technology for battle-space awareness and warfighter protection, based on microwave and millimeter-wave Doppler radar motion sensing devices that detect human presence. This technology will help overcome a shortfall of current see-through-thewall (STTW) systems, which is, the poor detection of stationary personnel. By detecting the minute Doppler shifts induced by a subject's cardiopulmonary related chest motion, the technology will allow users to detect personnel that are completely stationary more effectively. This personnel detection technique can also have an extremely low probability of intercept since the signals used can be those from everyday communications. The software and hardware developments and challenges for personnel detection and count at a distance will be discussed, including a 2.4 GHz quadrature radar single-chip silicon CMOS implementation, a low-power double side-band Ka-band transmission radar, and phase demodulation and heart rate extraction algorithms. In addition, the application of MIMO techniques for determining the number of subjects will be discussed.

  19. Doppler weather radar as a meteorite recovery tool

    NASA Astrophysics Data System (ADS)

    Fries, Marc; Fries, Jeffrey

    2010-09-01

    We report the use of Doppler weather radar as a tool for locating meteorites, both at the time of a fall and from archived radar data. This asset is especially useful for meteorite recovery as it can provide information on the whereabouts of falling meteorites in "dark flight" portion of their descent where information on their flight paths cannot be discerned from more traditional meteorite location techniques such as eyewitness accounts. Weather radar data can provide information from detection in three distinct regimes: (A) direct detection of the rapidly moving, optically bright fireball by distant radars, (B) detection of falling debris to include hand-sample sized rocks, and (C) detection of dust produced by detonation events that can occur tens of minutes and many kilometers laterally removed from the actual fireball locality. We present examples of each, as well as comparisons against man-made debris from a re-entering Soyuz rocket and the Stardust Sample Return Capsule. The use of Doppler weather radar as a supplement to traditional meteorite recovery methods holds the promise of improving both the speed and total number of meteorite recoveries, thereby increasing the number of freshly fallen meteorites for scientific study.

  20. On-The-Fly Neutron Doppler Broadening in MCNP

    NASA Astrophysics Data System (ADS)

    Martin, William R.; Brown, Forrest B.; Wilderman, Scott; Yesilyurt, Gokhan

    2014-06-01

    Multi-physics calculations may involve coupling continuous-energy Monte Carlo neutronics codes to CFD codes that provide many thousands or even millions of region temperatures. The traditional Monte Carlo approach - using precalculated Doppler broadened nuclear cross-sections - is not feasible for these large multiphysics problems. Instead, an On-the-Fly (OTF) Doppler broadening methodology is required, whereby neutron cross-sections are broadened during the Monte Carlo transport. To this end, we have developed a methodology for MCNP to provide OTF broadening based on cell temperatures during neutron tracking. The method enables the use of many thousands or more temperatures in MCNP Monte Carlo calculations for multiphysics applications, significantly advancing the state-of-the-art by permitting the solution of problems that were not previously possible with continuous-energy Monte Carlo codes. A production library with an extended set of isotopes has been developed for use with MCNP6. Calculations of test problems with MCNP6 and the new library demonstrate the accuracy and effectiveness of the OTF approach.

  1. Transcranial Doppler ultrasonography: From methodology to major clinical applications

    PubMed Central

    D’Andrea, Antonello; Conte, Marianna; Cavallaro, Massimo; Scarafile, Raffaella; Riegler, Lucia; Cocchia, Rosangela; Pezzullo, Enrica; Carbone, Andreina; Natale, Francesco; Santoro, Giuseppe; Caso, Pio; Russo, Maria Giovanna; Bossone, Eduardo; Calabrò, Raffaele

    2016-01-01

    Non-invasive Doppler ultrasonographic study of cerebral arteries [transcranial Doppler (TCD)] has been extensively applied on both outpatient and inpatient settings. It is performed placing a low-frequency (≤ 2 MHz) transducer on the scalp of the patient over specific acoustic windows, in order to visualize the intracranial arterial vessels and to evaluate the cerebral blood flow velocity and its alteration in many different conditions. Nowadays the most widespread indication for TCD in outpatient setting is the research of right to left shunting, responsable of so called “paradoxical embolism”, most often due to patency of foramen ovale which is responsable of the majority of cryptogenic strokes occuring in patients younger than 55 years old. TCD also allows to classify the grade of severity of such shunts using the so called “microembolic signal grading score”. In addition TCD has found many useful applications in neurocritical care practice. It is useful on both adults and children for day-to-day bedside assessment of critical conditions including vasospasm in subarachnoidal haemorrhage (caused by aneurysm rupture or traumatic injury), traumatic brain injury, brain stem death. It is used also to evaluate cerebral hemodynamic changes after stroke. It also allows to investigate cerebral pressure autoregulation and for the clinical evaluation of cerebral autoregulatory reserve. PMID:27468332

  2. Electroencephalography and transcranial Doppler ultrasonography in neonatal citrullinemia.

    PubMed

    Su, Pen-Hua; Chen, Jia-Yuh; Chen, Yung-Jung; Niu, Dau-Ming; Hsu, Ju-Hui; Lee, Inn-Chi

    2014-11-01

    The authors present a case of citrullinemia with a genotype of argininosuccinate synthetase (ASS1), c.380 G>A (p.R127Q)/c.380 G>A (p.R127Q), in two alleles. A 3-day-old female infant presented with status epilepticus and coma. Laboratory data showed hyperammonemia and marked lactic acidosis in the blood and cerebrospinal fluid; electroencephalography showed severely suppressed cerebral activity and focal paroxysmal volleys of slow and sharp waves (< 1Hz) over the left hemisphere. Real-time transcranial Doppler ultrasonography showed a brain edema and high peaked systolic and low diastolic flows in basal, anterior, and middle cerebral arteries; however, immediately after a blood exchange transfusion, systolic flows were lower and diastolic flows were higher. The resistance indices were significantly different (means: 0.58 vs. 0.37; p=0.01). The patient was placed on diet therapy. After six blood exchange transfusions and peritoneal dialysis, her neurologic examination results and serum ammonia and lactate values were normal. The authors found that electroencephalography and transcranial Doppler ultrasonography were useful for the diagnosis and follow-up treatment of neonatal citrullinemia.

  3. Simultaneous 2D Doppler backscattering from edge turbulence

    NASA Astrophysics Data System (ADS)

    Thomas, David; Brunner, Kai; Freethy, Simon; Huang, Billy; Shevchenko, Vladimir; Vann, Roddy

    2015-11-01

    The Synthetic Aperture Microwave Imaging (SAMI) diagnostic (previously at MAST and now at NSTX-U) actively probes the plasma edge using a wide (80 degree beam width) and broadband (10-34.5 GHz) beam. It digitizes the phase and amplitude of the Doppler backscattered signal using a receiving array of eight antennas which can be focused in any direction post shot to an angular range of 6-24 degree FWHM. This allows Doppler BackScattering (DBS) experiments to be conducted in every direction within the field of view simultaneously. This capability is unique to SAMI and is a novel way of conducting DBS experiments. SAMI has measured the magnetic pitch angle in the edge for the first time using a backscattering diagnostic. This is possible with simultaneous 2D DBS because the maximum backscattered power is perpendicular to the turbulence and turbulence is elongated along the magnetic field. SAMI has also studied the effect of NBI and the L-H transition on turbulent velocity, and turbulence suppression in the edge during H-mode. Initial results from all of these studies will be presented. This work is supported by the Engineering and Physical Sciences Research Council Grants EP/K504178 and EP/H016732.

  4. Brunt-Doppler ducting of small-period gravity waves

    SciTech Connect

    Wang, D.Y.; Tuan, T.F. )

    1988-09-01

    The variation of the Brunt period with height lends itself to a natural ducting and filtering mechanism for low-altitude short-period gravity waves. The authors investigate this mechanism in combination with Doppler ducting produced by the variation in horizontal winds. Both the frequency dispersion at fixed propagation direction and the direction dispersion at fixed frequency have been examined in a COSPAR background atmosphere with zonal and meridional winds. The results show that not only are the low-altitude short-period gravity waves ducted, but unlike the usual ducting mechanisms due to uneven structure and dissipation which produce only partially guided modes, this mechanism produces primarily guided modes in the absence of winds and a mixture of fully and partially guided modes with winds. The wind effects are very large on the higher modes and less significant on the few lowest modes, including the Lamb mode. Investigation of viscous dissipation, nonlinearity, and instability have shown that viscosity is unimportant for most altitudes of interest and that nonlinearity and instability can play a role for all but the lowest guided modes. They propose that simultaneous continuous observation of airglow at mesospheric and ionospheric altitudes be made to verify not only the low-altitude Brunt-Doppler ducting for short-period gravity waves, but also the vertical energy distribution of the medium- and large-scale TIDs.

  5. Extremely high-frequency micro-Doppler measurements of humans

    NASA Astrophysics Data System (ADS)

    Hedden, Abigail S.; Silvious, Jerry L.; Dietlein, Charles R.; Green, Jeremy A.; Wikner, David A.

    2014-05-01

    The development of sensors that are capable of penetrating smoke, dust, fog, clouds, and rain is critical for maintaining situational awareness in degraded visual environments and for providing support to the Warfighter. Atmospheric penetration properties, the ability to form high-resolution imagery with modest apertures, and available source power make the extremely high-frequency (EHF) portion of the spectrum promising for the development of radio frequency (RF) sensors capable of penetrating visual obscurants. Comprehensive phenomenology studies including polarization and backscatter properties of relevant targets are lacking at these frequencies. The Army Research Laboratory (ARL) is developing a fully-polarimetric frequency-modulated continuous-wave (FMCW) instrumentation radar to explore polarization and backscatter properties of in-situ rain, scattering from natural and man-made surfaces, and the radar cross section and micro-Doppler signatures of humans at EHF frequencies, specifically, around the 220 GHz atmospheric window. This work presents an overview of the design and construction of the radar system, hardware performance, data acquisition software, and initial results including an analysis of human micro-Doppler signatures.

  6. [Placental 3D Doppler angiography: current and upcoming applications].

    PubMed

    Duan, J; Perdriolle-Galet, E; Chabot-Lecoanet, A-C; Callec, R; Beaumont, M; Chavatte-Palmer, P; Tsatsaris, V; Morel, O

    2015-02-01

    The placental dysfunction, which seems to be caused by a defect of trophoblastic invasion and impaired uterine vascular remodeling since the first trimester, is responsible in a non-exclusive way for the chronic placental hypoxia, resulting secondarily in the intra-uterine growth restriction (IUGR) and/or pre-eclampsia (PE). The quality of utero-placental vasculature is essential for a proper fetal development and a successful progress of pregnancy. However, the in vivo assessment of placental vascularization with non-invasive methods is complicated by the small size of placental terminal vessel and its complex architecture. Moreover, imaging with contrast agent is not recommended to pregnant women. Until recently, the fetal and maternal vascularization could only be evaluated through pulse Doppler of uterine arteries during pregnancy, which has little clinical value for utero-placental vascularization defects assessment. Recently, a non-invasive study, without use of contrast agent for vasculature evaluation of an organ of interest has become possible by the development of 3D Doppler angiography technique. The objective of this review was to make an inventory of its current and future applications for utero-placental vasculature quantification. The main findings of the literature on the assessment of utero-placental vascularization in physiological situation and major placental vascular dysfunction pathologies such as PE and IUGR were widely discussed.

  7. Doppler velocity measurements using a phase-stabilized michelson spectrometer

    NASA Astrophysics Data System (ADS)

    Smeets, G.

    1993-10-01

    Laser Doppler systems have become classical means of nonintrusively recording velocities in all kinds of flow fields. With the system mostly used, the so-called Doppler differential velocimeter, tracer particles incorporated in the flow are illuminated by two laser beams from slightly different directions, and the velocity is derived from the beating frequency of the two scattered light waves on the cathode of a photomultiplier. As the intersecting beams form equidistant light sheets within the probe volume by their interference, it is desirable, as is the case with any technique creating light barriers in space, that particles should pass the grid individually. The particles should be of a suitable size: large enough to scatter sufficient light for a good signal-to-noise ratio but small enough for negligible velocity relaxation and true indication of the turbulent velocity fluctuations. In most applications of this technique, e.g. in wind tunnel experiments, particles of controlled size and number density are seeded into the upstream flow.

  8. Detection of Doppler Microembolic Signals Using High Order Statistics

    PubMed Central

    Geryes, Maroun; Hassan, Walid; Mcheick, Ali

    2016-01-01

    Robust detection of the smallest circulating cerebral microemboli is an efficient way of preventing strokes, which is second cause of mortality worldwide. Transcranial Doppler ultrasound is widely considered the most convenient system for the detection of microemboli. The most common standard detection is achieved through the Doppler energy signal and depends on an empirically set constant threshold. On the other hand, in the past few years, higher order statistics have been an extensive field of research as they represent descriptive statistics that can be used to detect signal outliers. In this study, we propose new types of microembolic detectors based on the windowed calculation of the third moment skewness and fourth moment kurtosis of the energy signal. During energy embolus-free periods the distribution of the energy is not altered and the skewness and kurtosis signals do not exhibit any peak values. In the presence of emboli, the energy distribution is distorted and the skewness and kurtosis signals exhibit peaks, corresponding to the latter emboli. Applied on real signals, the detection of microemboli through the skewness and kurtosis signals outperformed the detection through standard methods. The sensitivities and specificities reached 78% and 91% and 80% and 90% for the skewness and kurtosis detectors, respectively. PMID:28096889

  9. Rayleigh-backscattering doppler broadening correction for differential absorption lidar

    NASA Astrophysics Data System (ADS)

    Fan, Lanlan; Zhang, Yinchao; Chen, Siying; Guo, Pan; Chen, He

    2015-11-01

    The spectral broadening by Rayleigh backscattering can cause large changes in water vapor echo signals, causing errors when the water vapor concentration is inversed by differential absorption lidar (DIAL). A correction algorithm is proposed to revise the errors due to the effect of laser spectral broadening. The relative errors of water vapor are calculated in cases of different aerosol distribution and temperature changes before and after correction. The results show that measurement errors due to the Doppler broadening are more than 5% before correction and a 2% measurement error after corrected for the case of a smooth, background aerosol distribution. However, due to the high aerosol gradients and strong temperature inversion, errors can be up to 40% and 10% with no corrections for this effect, respectively. The relative errors can reduce to less than 2% after correction. Hence, the correction algorithm for Rayleigh Doppler broadening can improve detection accuracy in H2O DIAL measurements especially when it is applied to high aerosol concentration or strong temperature inversion.

  10. Doppler radar sensor positioning in a fall detection system.

    PubMed

    Liu, Liang; Popescu, Mihail; Ho, K C; Skubic, Marjorie; Rantz, Marilyn

    2012-01-01

    Falling is a common health problem for more than a third of the United States population over 65. We are currently developing a Doppler radar based fall detection system that already has showed promising results. In this paper, we study the sensor positioning in the environment with respect to the subject. We investigate three sensor positions, floor, wall and ceiling of the room, in two experimental configurations. Within each system configuration, subjects performed falls towards or across the radar sensors. We collected 90 falls and 341 non falls for the first configuration and 126 falls and 817 non falls for the second one. Radar signature classification was performed using a SVM classifier. Fall detection performance was evaluated using the area under the ROC curves (AUCs) for each sensor deployment. We found that a fall is more likely to be detected if the subject is falling toward or away from the sensor and a ceiling Doppler radar is more reliable for fall detection than a wall mounted one.

  11. Modeling of Doppler frequency shift in multipath radiochannels

    NASA Astrophysics Data System (ADS)

    Penzin, Maksim; Iyin, Nikolay

    2016-06-01

    We discuss the modeling of propagation of a quasi-monochromatic radio signal, represented by a coherent pulse sequence, in a non-stationary multipath radio channel. In such a channel, signal propagation results in the observed frequency shift for each ray (Doppler effect). The modeling is based on the assumption that during propagation of a single pulse a channel can be considered stationary. A phase change in the channel transfer function is shown to cause the observed frequency shift in the received signal. Thus, instead of measuring the Doppler frequency shift, we can measure the rate of change in the mean phase of one pulse relative to another. The modeling is carried out within the framework of the method of normal waves. The method enables us to model the dynamics of the electromagnetic field at a given point with the required accuracy. The modeling reveals that a local change in ionospheric conditions more severely affects the rays whose reflection region is in the area where the changes occur.

  12. Tropospheric Wind Profile Measurements with a Direct Detection Doppler Lidar

    NASA Technical Reports Server (NTRS)

    Gentry, Bruce M.; Li, Steven X.; Korb, C. Laurence; Chen, Huailin; Mathur, Savyasachee

    1998-01-01

    Research has established the importance of global tropospheric wind measurements for large scale improvements in numerical weather prediction. In addition, global wind measurements provide data that are fundamental to the understanding and prediction of global climate change. These tasks are closely linked with the goals of the NASA Earth Science Enterprise and Global Climate Change programs. NASA Goddard has been actively involved in the development of direct detection Doppler lidar methods and technologies to meet the wind observing needs of the atmospheric science community. In this paper we describe a recently developed prototype wind lidar system using a direct detection Doppler technique for measuring wind profiles from the surface through the troposphere. This system uses a pulsed ND:YAG laser operating at 1064 nm as the transmitter. The laser pulse is directed to the atmosphere using a 40 cm diameter scan mirror. The portion of the laser energy backscattered from aerosols and molecules is collected by a 40 cm diameter telescope and coupled via fiber optics into the Doppler receiver. Single photon counting APD's are used to detect the atmospheric backscattered signal. The principle element of the receiver is a dual bandpass tunable Fabry Perot etalon which analyzes the Doppler shift of the incoming laser signal using the double edge technique. The double edge technique uses two high resolution optical filters having bandpasses offset relative to one another such that the 'edge' of the first filter's transmission function crosses that of the second at the half power point. The outgoing laser frequency is located approximately at the crossover point. Due to the opposite going slopes of the edges, a Doppler shift in the atmospheric backscattered laser frequency produces a positive change in signal for one filter and a negative change in the second filter. Taking the ratio of the two edge channel signals yields a result which is directly proportional to the

  13. Detection of gravitational radiation and oscillations of the sun via Doppler tracking of spacecraft

    NASA Technical Reports Server (NTRS)

    Douglas, D. H.

    1978-01-01

    The magnitude of Doppler signals produced by gravitational wave burst, continuous gravitational waves, and oscillations of the sun interacting with a spacecraft are considered. Expressions are worked out for the appropriate noise entering each measurement. The noise sources considered are the Doppler extractor, fluctuations in the solar wind and the troposphere, and fluctuations in the reference oscillator.

  14. The effect of dead elements on the accuracy of Doppler ultrasound measurements.

    PubMed

    Vachutka, Jaromir; Dolezal, Ladislav; Kollmann, Christian; Klein, Jakob

    2014-01-01

    The objective of this study is to investigate the effect of multiple dead elements in an ultrasound probe on the accuracy of Doppler ultrasound measurements. For this work, we used a specially designed ultrasound imaging system, the Ultrasonix Sonix RP, that provides the user with the ability to disable selected elements in the probe. Using fully functional convex, linear, and phased array probes, we established a performance baseline by measuring the parameters of a laminar parabolic flow profile. These same parameters were then measured using probes with 1 to 10 disabled elements. The acquired velocity spectra from the functional probes and the probes with disabled elements were then analyzed to determine the overall Doppler power, maximum flow velocity, and average flow velocity. Color Flow Doppler images were also evaluated in a similar manner. The analysis of the Doppler spectra indicates that the overall Doppler power as well as the detected maximum and average velocities decrease with the increasing number of disabled elements. With multiple disabled elements, decreases in the detected maximum and average velocities greater than 20% were recorded. Similar results were also observed with Color Flow Doppler measurements. Our results confirmed that the degradation of the ultrasound probe through the loss of viable elements will negatively affect the quality of the Doppler-derived diagnostic information. We conclude that the results of Doppler measurements cannot be considered accurate or reliable if there are four or more contiguous dead elements in any given probe.

  15. Is Doppler tissue velocity during early left ventricular filling preload independent?

    NASA Technical Reports Server (NTRS)

    Yalcin, F.; Kaftan, A.; Muderrisoglu, H.; Korkmaz, M. E.; Flachskampf, F.; Garcia, M.; Thomas, J. D.

    2002-01-01

    BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.

  16. Designing clutter rejection filters with complex coefficients for airborne pulsed Doppler weather radar

    NASA Technical Reports Server (NTRS)

    Jamora, Dennis A.

    1993-01-01

    Ground clutter interference is a major problem for airborne pulse Doppler radar operating at low altitudes in a look-down mode. With Doppler zero set at the aircraft ground speed, ground clutter rejection filtering is typically accomplished using a high-pass filter with real valued coefficients and a stopband notch centered at zero Doppler. Clutter spectra from the NASA Wind Shear Flight Experiments of l991-1992 show that the dominant clutter mode can be located away from zero Doppler, particularly at short ranges dominated by sidelobe returns. Use of digital notch filters with complex valued coefficients so that the stopband notch can be located at any Doppler frequency is investigated. Several clutter mode tracking algorithms are considered to estimate the Doppler frequency location of the dominant clutter mode. From the examination of night data, when a dominant clutter mode away from zero Doppler is present, complex filtering is able to significantly increase clutter rejection over use of a notch filter centered at zero Doppler.

  17. Direct Measurement of Basilar Membrane Motion Using Pulsed-Wave Doppler High-Frequency Ultrasound

    NASA Astrophysics Data System (ADS)

    Torbatian, Z.; Garland, P.; Adamson, R. B. A.; Bance, M.; Brown, J. A.

    2011-11-01

    We present a preliminary report on the use of a new technique for measuring the motion of the basilar membrane, high-frequency ultrasound Doppler vibrometry. Using a custom-built, 1 mm diameter probe, we collected ultrasonic reflections from intracochlear structures and applied pulsed-wave Doppler vibrometry to measure the basilar membrane response to pressure applied in the ear canal.

  18. Doppler Asymmetric Spatial Heterodyne Spectroscopy (DASH): An Innovative Concept for Measuring Winds in Planetary Atmospheres

    DTIC Science & Technology

    2006-01-01

    Doppler Asymmetric Spatial Heterodyne Spectroscopy (DASH): An innovative concept for measuring winds in planetary atmospheres Christoph R...USA Keywords: Wind, atmospheric dynamics, Doppler imaging, Spatial Heterodyne Spectroscopy , Michelson Interferometer, planetary atmospheres...Heterodyne Spectroscopy (DASH): An innovative concept for measuring winds in planetary atmospheres 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM

  19. Correction of Doppler Rada Data for Aircraft Motion Using Surface Measurements and Recursive Least-Squares Estimation

    NASA Technical Reports Server (NTRS)

    Durden, S.; Haddad, Z.

    1998-01-01

    Observations of Doppler velocity of hydrometeors form airborne Doppler weather radars normally contains a component due to the aircraft motion. Accurate hydrometeor velocity measurements thus require correction by subtracting this velocity from the observed velocity.

  20. Postoperative monitoring of free flap reconstruction: A comparison of external Doppler ultrasonography and the implantable Doppler probe

    PubMed Central

    Hosein, Rayaad C; Cornejo, Agustin; Wang, Howard T

    2016-01-01

    HYPOTHESIS: The time to detection of vascular compromise and the postoperative time to re-exploration are shorter using the implantable Doppler (ID) probe, thereby resulting in earlier surgical re-exploration and a higher flap salvage rate. METHODS: A single-centre experience with 176 consecutive free flap reconstructions in 167 patients from 2000 to 2008 in a university-based teaching hospital by retrospective chart review is presented. RESULTS: There was a significant difference in overall flap survival (ID 98.0%, external Doppler [ED] 89.3%) and total flap loss (ID 2.0%, ED 10.7%) between the two groups (P=0.03). The difference in flap salvage rate was not significant (ID 90.9%, ED 63.6%; P=0.068). The false-positive (ID 0%, ED 3%; P=0.18) and false-negative rates (ID 0.0%, ED 4.5%; P=1.0) were not significantly different. There was also a lower median postoperative time to re-exploration for the ID group, from 48 h to one week after initial surgery (ID 74.5 h, ED 136.8 h; P=0.05). CONCLUSION: The present analysis revealed a potential benefit for the ID probe in the postoperative monitoring of free tissue transfers. PMID:27054132