ERIC Educational Resources Information Center
Sandler, Andrew B.
Statistical significance is misused in educational and psychological research when it is applied as a method to establish the reliability of research results. Other techniques have been developed which can be correctly utilized to establish the generalizability of findings. Methods that do provide such estimates are known as invariance or…
A Statistical Method for Syntactic Dialectometry
ERIC Educational Resources Information Center
Sanders, Nathan C.
2010-01-01
This dissertation establishes the utility and reliability of a statistical distance measure for syntactic dialectometry, expanding dialectometry's methods to include syntax as well as phonology and the lexicon. It establishes the measure's reliability by comparing its results to those of dialectology and phonological dialectometry on Swedish…
Establishing Inter- and Intrarater Reliability for High-Stakes Testing Using Simulation.
Kardong-Edgren, Suzan; Oermann, Marilyn H; Rizzolo, Mary Anne; Odom-Maryon, Tamara
This article reports one method to develop a standardized training method to establish the inter- and intrarater reliability of a group of raters for high-stakes testing. Simulation is used increasingly for high-stakes testing, but without research into the development of inter- and intrarater reliability for raters. Eleven raters were trained using a standardized methodology. Raters scored 28 student videos over a six-week period. Raters then rescored all videos over a two-day period to establish both intra- and interrater reliability. One rater demonstrated poor intrarater reliability; a second rater failed all students. Kappa statistics improved from the moderate to substantial agreement range with the exclusion of the two outlier raters' scores. There may be faculty who, for different reasons, should not be included in high-stakes testing evaluations. All faculty are content experts, but not all are expert evaluators.
ERIC Educational Resources Information Center
Giesen, J. Martin; And Others
The study was designed to determine the reliability and criterion validity of a psychomotor performance test (the Fine Finger Dexterity Work Task Unit) with 40 partially or totally blind adults. Reliability was established by using the test-retest method. A supervisory rating was developed and the reliability established by using the split-half…
A Comparison of Two Methods of Determining Interrater Reliability
ERIC Educational Resources Information Center
Fleming, Judith A.; Taylor, Janeen McCracken; Carran, Deborah
2004-01-01
This article offers an alternative methodology for practitioners and researchers to use in establishing interrater reliability for testing purposes. The majority of studies on interrater reliability use a traditional methodology where by two raters are compared using a Pearson product-moment correlation. This traditional method of estimating…
A hydrostatic weighing method using total lung capacity and a small tank.
Warner, J G; Yeater, R; Sherwood, L; Weber, K
1986-01-01
The purpose of this study was to establish the validity and reliability of a hydrostatic weighing method using total lung capacity (measuring vital capacity with a respirometer at the time of weighing) the prone position, and a small oblong tank. The validity of the method was established by comparing the TLC prone (tank) method against three hydrostatic weighing methods administered in a pool. The three methods included residual volume seated, TLC seated and TLC prone. Eighty male and female subjects were underwater weighed using each of the four methods. Validity coefficients for per cent body fat between the TLC prone (tank) method and the RV seated (pool), TLC seated (pool) and TLC prone (pool) methods were .98, .99 and .99, respectively. A randomised complete block ANOVA found significant differences between the RV seated (pool) method and each of the three TLC methods with respect to both body density and per cent body fat. The differences were negligible with respect to HW error. Reliability of the TLC prone (tank) method was established by weighing twenty subjects three different times with ten-minute time intervals between testing. Multiple correlations yielded reliability coefficients for body density and per cent body fat values of .99 and .99, respectively. It was concluded that the TLC prone (tank) method is valid, reliable and a favourable method of hydrostatic weighing. PMID:3697596
A hydrostatic weighing method using total lung capacity and a small tank.
Warner, J G; Yeater, R; Sherwood, L; Weber, K
1986-03-01
The purpose of this study was to establish the validity and reliability of a hydrostatic weighing method using total lung capacity (measuring vital capacity with a respirometer at the time of weighing) the prone position, and a small oblong tank. The validity of the method was established by comparing the TLC prone (tank) method against three hydrostatic weighing methods administered in a pool. The three methods included residual volume seated, TLC seated and TLC prone. Eighty male and female subjects were underwater weighed using each of the four methods. Validity coefficients for per cent body fat between the TLC prone (tank) method and the RV seated (pool), TLC seated (pool) and TLC prone (pool) methods were .98, .99 and .99, respectively. A randomised complete block ANOVA found significant differences between the RV seated (pool) method and each of the three TLC methods with respect to both body density and per cent body fat. The differences were negligible with respect to HW error. Reliability of the TLC prone (tank) method was established by weighing twenty subjects three different times with ten-minute time intervals between testing. Multiple correlations yielded reliability coefficients for body density and per cent body fat values of .99 and .99, respectively. It was concluded that the TLC prone (tank) method is valid, reliable and a favourable method of hydrostatic weighing.
Establishing monitoring programs for travel time reliability.
DOT National Transportation Integrated Search
2014-01-01
Within the second Strategic Highway Research Program (SHRP 2), Project L02 focused on creating a suite of methods by which transportation agencies could monitor and evaluate travel time reliability. Creation of the methods also produced an improved u...
Development of a probabilistic analysis methodology for structural reliability estimation
NASA Technical Reports Server (NTRS)
Torng, T. Y.; Wu, Y.-T.
1991-01-01
The novel probabilistic analysis method for assessment of structural reliability presented, which combines fast-convolution with an efficient structural reliability analysis, can after identifying the most important point of a limit state proceed to establish a quadratic-performance function. It then transforms the quadratic function into a linear one, and applies fast convolution. The method is applicable to problems requiring computer-intensive structural analysis. Five illustrative examples of the method's application are given.
A Method to Establish Stimulus Control and Compliance with Instructions
ERIC Educational Resources Information Center
Borgen, John G.; Mace, F. Charles; Cavanaugh, Brenna M.; Shamlian, Kenneth; Lit, Keith R.; Wilson, Jillian B.; Trauschke, Stephanie L.
2017-01-01
We evaluated a unique procedure to establish compliance with instructions in four young children diagnosed with autism spectrum disorder (ASD) who had low levels of compliance. Our procedure included methods to establish a novel therapist as a source of positive reinforcement, reliably evoke orienting responses to the therapist, increase the…
Impact of coverage on the reliability of a fault tolerant computer
NASA Technical Reports Server (NTRS)
Bavuso, S. J.
1975-01-01
A mathematical reliability model is established for a reconfigurable fault tolerant avionic computer system utilizing state-of-the-art computers. System reliability is studied in light of the coverage probabilities associated with the first and second independent hardware failures. Coverage models are presented as a function of detection, isolation, and recovery probabilities. Upper and lower bonds are established for the coverage probabilities and the method for computing values for the coverage probabilities is investigated. Further, an architectural variation is proposed which is shown to enhance coverage.
Interrelation Between Safety Factors and Reliability
NASA Technical Reports Server (NTRS)
Elishakoff, Isaac; Chamis, Christos C. (Technical Monitor)
2001-01-01
An evaluation was performed to establish relationships between safety factors and reliability relationships. Results obtained show that the use of the safety factor is not contradictory to the employment of the probabilistic methods. In many cases the safety factors can be directly expressed by the required reliability levels. However, there is a major difference that must be emphasized: whereas the safety factors are allocated in an ad hoc manner, the probabilistic approach offers a unified mathematical framework. The establishment of the interrelation between the concepts opens an avenue to specify safety factors based on reliability. In cases where there are several forms of failure, then the allocation of safety factors should he based on having the same reliability associated with each failure mode. This immediately suggests that by the probabilistic methods the existing over-design or under-design can be eliminated. The report includes three parts: Part 1-Random Actual Stress and Deterministic Yield Stress; Part 2-Deterministic Actual Stress and Random Yield Stress; Part 3-Both Actual Stress and Yield Stress Are Random.
Design Optimization Method for Composite Components Based on Moment Reliability-Sensitivity Criteria
NASA Astrophysics Data System (ADS)
Sun, Zhigang; Wang, Changxi; Niu, Xuming; Song, Yingdong
2017-08-01
In this paper, a Reliability-Sensitivity Based Design Optimization (RSBDO) methodology for the design of the ceramic matrix composites (CMCs) components has been proposed. A practical and efficient method for reliability analysis and sensitivity analysis of complex components with arbitrary distribution parameters are investigated by using the perturbation method, the respond surface method, the Edgeworth series and the sensitivity analysis approach. The RSBDO methodology is then established by incorporating sensitivity calculation model into RBDO methodology. Finally, the proposed RSBDO methodology is applied to the design of the CMCs components. By comparing with Monte Carlo simulation, the numerical results demonstrate that the proposed methodology provides an accurate, convergent and computationally efficient method for reliability-analysis based finite element modeling engineering practice.
A criterion for establishing life limits. [for Space Shuttle Main Engine service
NASA Technical Reports Server (NTRS)
Skopp, G. H.; Porter, A. A.
1990-01-01
The development of a rigorous statistical method that would utilize hardware-demonstrated reliability to evaluate hardware capability and provide ground rules for safe flight margin is discussed. A statistical-based method using the Weibull/Weibayes cumulative distribution function is described. Its advantages and inadequacies are pointed out. Another, more advanced procedure, Single Flight Reliability (SFR), determines a life limit which ensures that the reliability of any single flight is never less than a stipulated value at a stipulated confidence level. Application of the SFR method is illustrated.
Empirical methods for assessing meaningful neuropsychological change following epilepsy surgery.
Sawrie, S M; Chelune, G J; Naugle, R I; Lüders, H O
1996-11-01
Traditional methods for assessing the neurocognitive effects of epilepsy surgery are confounded by practice effects, test-retest reliability issues, and regression to the mean. This study employs 2 methods for assessing individual change that allow direct comparison of changes across both individuals and test measures. Fifty-one medically intractable epilepsy patients completed a comprehensive neuropsychological battery twice, approximately 8 months apart, prior to any invasive monitoring or surgical intervention. First, a Reliable Change (RC) index score was computed for each test score to take into account the reliability of that measure, and a cutoff score was empirically derived to establish the limits of statistically reliable change. These indices were subsequently adjusted for expected practice effects. The second approach used a regression technique to establish "change norms" along a common metric that models both expected practice effects and regression to the mean. The RC index scores provide the clinician with a statistical means of determining whether a patient's retest performance is "significantly" changed from baseline. The regression norms for change allow the clinician to evaluate the magnitude of a given patient's change on 1 or more variables along a common metric that takes into account the reliability and stability of each test measure. Case data illustrate how these methods provide an empirically grounded means for evaluating neurocognitive outcomes following medical interventions such as epilepsy surgery.
Probabilistic fatigue methodology for six nines reliability
NASA Technical Reports Server (NTRS)
Everett, R. A., Jr.; Bartlett, F. D., Jr.; Elber, Wolf
1990-01-01
Fleet readiness and flight safety strongly depend on the degree of reliability that can be designed into rotorcraft flight critical components. The current U.S. Army fatigue life specification for new rotorcraft is the so-called six nines reliability, or a probability of failure of one in a million. The progress of a round robin which was established by the American Helicopter Society (AHS) Subcommittee for Fatigue and Damage Tolerance is reviewed to investigate reliability-based fatigue methodology. The participants in this cooperative effort are in the U.S. Army Aviation Systems Command (AVSCOM) and the rotorcraft industry. One phase of the joint activity examined fatigue reliability under uniquely defined conditions for which only one answer was correct. The other phases were set up to learn how the different industry methods in defining fatigue strength affected the mean fatigue life and reliability calculations. Hence, constant amplitude and spectrum fatigue test data were provided so that each participant could perform their standard fatigue life analysis. As a result of this round robin, the probabilistic logic which includes both fatigue strength and spectrum loading variability in developing a consistant reliability analysis was established. In this first study, the reliability analysis was limited to the linear cumulative damage approach. However, it is expected that superior fatigue life prediction methods will ultimately be developed through this open AHS forum. To that end, these preliminary results were useful in identifying some topics for additional study.
Models for evaluating the performability of degradable computing systems
NASA Technical Reports Server (NTRS)
Wu, L. T.
1982-01-01
Recent advances in multiprocessor technology established the need for unified methods to evaluate computing systems performance and reliability. In response to this modeling need, a general modeling framework that permits the modeling, analysis and evaluation of degradable computing systems is considered. Within this framework, several user oriented performance variables are identified and shown to be proper generalizations of the traditional notions of system performance and reliability. Furthermore, a time varying version of the model is developed to generalize the traditional fault tree reliability evaluation methods of phased missions.
NASA Astrophysics Data System (ADS)
Yang, Zhou; Zhu, Yunpeng; Ren, Hongrui; Zhang, Yimin
2015-03-01
Reliability allocation of computerized numerical controlled(CNC) lathes is very important in industry. Traditional allocation methods only focus on high-failure rate components rather than moderate failure rate components, which is not applicable in some conditions. Aiming at solving the problem of CNC lathes reliability allocating, a comprehensive reliability allocation method based on cubic transformed functions of failure modes and effects analysis(FMEA) is presented. Firstly, conventional reliability allocation methods are introduced. Then the limitations of direct combination of comprehensive allocation method with the exponential transformed FMEA method are investigated. Subsequently, a cubic transformed function is established in order to overcome these limitations. Properties of the new transformed functions are discussed by considering the failure severity and the failure occurrence. Designers can choose appropriate transform amplitudes according to their requirements. Finally, a CNC lathe and a spindle system are used as an example to verify the new allocation method. Seven criteria are considered to compare the results of the new method with traditional methods. The allocation results indicate that the new method is more flexible than traditional methods. By employing the new cubic transformed function, the method covers a wider range of problems in CNC reliability allocation without losing the advantages of traditional methods.
Effective Chemical Inactivation of Ebola Virus
Haddock, Elaine; Feldmann, Friederike
2016-01-01
Reliable inactivation of specimens before removal from high-level biocontainment is crucial for safe operation. To evaluate efficacy of methods of chemical inactivation, we compared in vitro and in vivo approaches using Ebola virus as a surrogate pathogen. Consequently, we have established parameters and protocols leading to reliable and effective inactivation. PMID:27070504
Institutional Research Needs for U. S. Community Colleges.
ERIC Educational Resources Information Center
Washington State Board for Community Coll. Education, Seattle. Research and Planning Office.
Seven problem areas where research is needed critically at the two-year institution level are identified: (1) establish reliability and stability of MIS/data base; (2) find reliable predictive instruments and/or formulae; (3) analyze support services and academic assistance objectives; (4) develop research methods to evaluate curricula; (5)…
NASA Technical Reports Server (NTRS)
Kleinhammer, Roger K.; Graber, Robert R.; DeMott, D. L.
2016-01-01
Reliability practitioners advocate getting reliability involved early in a product development process. However, when assigned to estimate or assess the (potential) reliability of a product or system early in the design and development phase, they are faced with lack of reasonable models or methods for useful reliability estimation. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, analysts attempt to develop the "best" or composite analog data to support the assessments. Industries, consortia and vendors across many areas have spent decades collecting, analyzing and tabulating fielded item and component reliability performance in terms of observed failures and operational use. This data resource provides a huge compendium of information for potential use, but can also be compartmented by industry, difficult to find out about, access, or manipulate. One method used incorporates processes for reviewing these existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component. It can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. It also establishes a baseline prior that may updated based on test data or observed operational constraints and failures, i.e., using Bayesian techniques. This tutorial presents a descriptive compilation of historical data sources across numerous industries and disciplines, along with examples of contents and data characteristics. It then presents methods for combining failure information from different sources and mathematical use of this data in early reliability estimation and analyses.
Kang, Edith; Fields, Henry W; Cornett, Sandy; Beck, F Michael
2005-01-01
The purpose of this study was to determine the appropriateness of nationally available dental information materials according to the suitability assessment of materials (SAM) method. Clinically related, professionally produced patient dental health education materials (N=22) provided by the American Academy of Pediatric Dentistry (AAPD) were evaluated using the SAM method that had previously been judged valid and reliable. A rater was trained by an experienced health literacy evaluator to establish validity. The rater then rated all materials for 5 categories of assessment (content, literacy demand, graphics, layout and typography, and learning stimulation/motivation) and an overall assessment, and repeated 5 materials to establish intrarater reliability. When compared to the experienced rater, the validity was K=0.43. The reliability was established for all ratings as K=0.52. The consistently weakest categories were content, graphics, and learning stimulation, while reading level as part of literacy demand was often not suitable. The overall suitability of the AAPD materials was generally classified as superior. Reliable and valid evaluation of available dental patient information materials can be accomplished. The materials were largely superior. There is great variability within the categories of evaluation. The categories of content, graphics, and learning stimulation require attention and could raise the overall quality of the materials.
Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.
2010-01-01
The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339
EVALUATION OF LITERATURE ESTABLISHING SCREENING LEVELS FOR TERRESTRIAL PLANTS/INVERTEBRATES
Scientific publications often lack key information on experimental design or do not follow appropriate test methods and therefore cannot be used in deriving reliable benchmarks. Risk based soil screening levels (Eco-SSLs) are being established for chemicals of concern to terrestr...
Reliability Evaluation of Machine Center Components Based on Cascading Failure Analysis
NASA Astrophysics Data System (ADS)
Zhang, Ying-Zhi; Liu, Jin-Tong; Shen, Gui-Xiang; Long, Zhe; Sun, Shu-Guang
2017-07-01
In order to rectify the problems that the component reliability model exhibits deviation, and the evaluation result is low due to the overlook of failure propagation in traditional reliability evaluation of machine center components, a new reliability evaluation method based on cascading failure analysis and the failure influenced degree assessment is proposed. A direct graph model of cascading failure among components is established according to cascading failure mechanism analysis and graph theory. The failure influenced degrees of the system components are assessed by the adjacency matrix and its transposition, combined with the Pagerank algorithm. Based on the comprehensive failure probability function and total probability formula, the inherent failure probability function is determined to realize the reliability evaluation of the system components. Finally, the method is applied to a machine center, it shows the following: 1) The reliability evaluation values of the proposed method are at least 2.5% higher than those of the traditional method; 2) The difference between the comprehensive and inherent reliability of the system component presents a positive correlation with the failure influenced degree of the system component, which provides a theoretical basis for reliability allocation of machine center system.
Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi
2015-05-01
Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. The root mean square errors for the humeral coordinate system were <1.0 mm/1.0° for comparison of all translations/rotations obtained by a single tester and <1.0 mm/2.0° for comparison obtained by 2 different testers. Assessment of reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
A study on the real-time reliability of on-board equipment of train control system
NASA Astrophysics Data System (ADS)
Zhang, Yong; Li, Shiwei
2018-05-01
Real-time reliability evaluation is conducive to establishing a condition based maintenance system for the purpose of guaranteeing continuous train operation. According to the inherent characteristics of the on-board equipment, the connotation of reliability evaluation of on-board equipment is defined and the evaluation index of real-time reliability is provided in this paper. From the perspective of methodology and practical application, the real-time reliability of the on-board equipment is discussed in detail, and the method of evaluating the realtime reliability of on-board equipment at component level based on Hidden Markov Model (HMM) is proposed. In this method the performance degradation data is used directly to realize the accurate perception of the hidden state transition process of on-board equipment, which can achieve a better description of the real-time reliability of the equipment.
NASA Astrophysics Data System (ADS)
Lamour, B. G.; Harris, R. T.; Roberts, A. G.
2010-06-01
Power system reliability problems are very difficult to solve because the power systems are complex and geographically widely distributed and influenced by numerous unexpected events. It is therefore imperative to employ the most efficient optimization methods in solving the problems relating to reliability of the power system. This paper presents a reliability analysis and study of the power interruptions resulting from severe power outages in the Nelson Mandela Bay Municipality (NMBM), South Africa and includes an overview of the important factors influencing reliability, and methods to improve the reliability. The Blue Horizon Bay 22 kV overhead line, supplying a 6.6 kV residential sector has been selected. It has been established that 70% of the outages, recorded at the source, originate on this feeder.
NASA Technical Reports Server (NTRS)
Wallace, Dolores R.
2003-01-01
In FY01 we learned that hardware reliability models need substantial changes to account for differences in software, thus making software reliability measurements more effective, accurate, and easier to apply. These reliability models are generally based on familiar distributions or parametric methods. An obvious question is 'What new statistical and probability models can be developed using non-parametric and distribution-free methods instead of the traditional parametric method?" Two approaches to software reliability engineering appear somewhat promising. The first study, begin in FY01, is based in hardware reliability, a very well established science that has many aspects that can be applied to software. This research effort has investigated mathematical aspects of hardware reliability and has identified those applicable to software. Currently the research effort is applying and testing these approaches to software reliability measurement, These parametric models require much project data that may be difficult to apply and interpret. Projects at GSFC are often complex in both technology and schedules. Assessing and estimating reliability of the final system is extremely difficult when various subsystems are tested and completed long before others. Parametric and distribution free techniques may offer a new and accurate way of modeling failure time and other project data to provide earlier and more accurate estimates of system reliability.
Predictions of Crystal Structure Based on Radius Ratio: How Reliable Are They?
ERIC Educational Resources Information Center
Nathan, Lawrence C.
1985-01-01
Discussion of crystalline solids in undergraduate curricula often includes the use of radius ratio rules as a method for predicting which type of crystal structure is likely to be adopted by a given ionic compound. Examines this topic, establishing more definitive guidelines for the use and reliability of the rules. (JN)
Aerts, Frank; Carrier, Kathy; Alwood, Becky
2016-01-01
Background: The assessment of clinical manifestation of muscle fatigue is an effective procedure in establishing therapeutic exercise dose. Few studies have evaluated physical therapist reliability in establishing muscle fatigue through detection of changes in quality of movement patterns in a live setting. Objective: The purpose of this study is to evaluate the inter-rater reliability of physical therapists’ ability to detect altered movement patterns due to muscle fatigue. Design: A reliability study in a live setting with multiple raters. Participants: Forty-four healthy individuals (ages 19-35) were evaluated by six physical therapists in a live setting. Methods: Participants were evaluated by physical therapists for altered movement patterns during resisted shoulder rotation. Each participant completed a total of four tests: right shoulder internal rotation, right shoulder external rotation, left shoulder internal rotation and left shoulder external rotation. Results: For all tests combined, the inter-rater reliability for a single rater scoring ICC (2,1) was .65 (95%, .60, .71) This corresponds to moderate inter-rater reliability between physical therapists. Limitations: The results of this study apply only to healthy participants and therefore cannot be generalized to a symptomatic population. Conclusion: Moderate inter-rater reliability was found between physical therapists in establishing muscle fatigue through the observation of sustained altered movement patterns during dynamic resistive shoulder internal and external rotation. PMID:27347241
ERIC Educational Resources Information Center
Dirlikov, Benjamin; Younes, Laurent; Nebel, Mary Beth; Martinelli, Mary Katherine; Tiedemann, Alyssa Nicole; Koch, Carolyn A.; Fiorilli, Diana; Bastian, Amy J.; Denckla, Martha Bridge; Miller, Michael I.; Mostofsky, Stewart H.
2017-01-01
This study presents construct validity for a novel automated morphometric and kinematic handwriting assessment, including (1) convergent validity, establishing reliability of automated measures with traditional manual-derived Minnesota Handwriting Assessment (MHA), and (2) discriminant validity, establishing that the automated methods distinguish…
A Valid and Reliable Instrument for Cognitive Complexity Rating Assignment of Chemistry Exam Items
ERIC Educational Resources Information Center
Knaus, Karen; Murphy, Kristen; Blecking, Anja; Holme, Thomas
2011-01-01
The design and use of a valid and reliable instrument for the assignment of cognitive complexity ratings to chemistry exam items is described in this paper. Use of such an instrument provides a simple method to quantify the cognitive demands of chemistry exam items. Instrument validity was established in two different ways: statistically…
Jung, Kyoung-Sim; Jung, Jin-Hwa; In, Tae-Sung; Cho, Hwi-Young
2016-09-01
[Purpose] The purpose of this study was to establish the reliability and validity of the Short Musculoskeletal Function Assessment questionnaire, which was translated into Korean, for patients with musculoskeletal disorder. [Subjects and Methods] Fifty-five subjects (26 males and 29 females) with musculoskeletal diseases participated in the study. The Short Musculoskeletal Function Assessment questionnaire focuses on a limited range of physical functions and includes a dysfunction index and a bother index. Reliability was determined using the intraclass correlation coefficient, and validity was examined by correlating short musculoskeletal function assessment scores with the 36-item Short-Form Health Survey (SF-36) score. [Results] The reliability was 0.97 for the dysfunction index and 0.94 for the bother index. Validity was established by comparison with Korean version of the SF-36. [Conclusion] This study demonstrated that the Korean version of the Short Musculoskeletal Function Assessment questionnaire is a reliable and valid instrument for the assessment of musculoskeletal disorders.
NASA Astrophysics Data System (ADS)
Creagh, Dudley; Cameron, Alyce
2017-08-01
When skeletonized remains are found it becomes a police task to determine to identify the body and establish the cause of death. It assists investigators if the Post-Mortem Interval (PMI) can be established. Hitherto no reliable qualitative method of estimating the PMI has been found. A quantitative method has yet to be developed. This paper shows that IR spectroscopy and Raman microscopy have the potential to form the basis of a quantitative method.
Crockford, Christopher; Newton, Judith; Lonergan, Katie; Madden, Caoifa; Mays, Iain; O'Sullivan, Meabhdh; Costello, Emmet; Pinto-Grau, Marta; Vajda, Alice; Heverin, Mark; Pender, Niall; Al-Chalabi, Ammar; Hardiman, Orla; Abrahams, Sharon
2018-02-01
Cognitive impairment affects approximately 50% of people with amyotrophic lateral sclerosis (ALS). Research has indicated that impairment may worsen with disease progression. The Edinburgh Cognitive and Behavioural ALS Screen (ECAS) was designed to measure neuropsychological functioning in ALS, with its alternate forms (ECAS-A, B, and C) allowing for serial assessment over time. The aim of the present study was to establish reliable change scores for the alternate forms of the ECAS, and to explore practice effects and test-retest reliability of the ECAS's alternate forms. Eighty healthy participants were recruited, with 57 completing two and 51 completing three assessments. Participants were administered alternate versions of the ECAS serially (A-B-C) at four-month intervals. Intra-class correlation analysis was employed to explore test-retest reliability, while analysis of variance was used to examine the presence of practice effects. Reliable change indices (RCI) and regression-based methods were utilized to establish change scores for the ECAS alternate forms. Test-retest reliability was excellent for ALS Specific, ALS Non-Specific, and ECAS Total scores of the combined ECAS A, B, and C (all > .90). No significant practice effects were observed over the three testing sessions. RCI and regression-based methods produced similar change scores. The alternate forms of the ECAS possess excellent test-retest reliability in a healthy control sample, with no significant practice effects. The use of conservative RCI scores is recommended. Therefore, a change of ≥8, ≥4, and ≥9 for ALS Specific, ALS Non-Specific, and ECAS Total score is required for reliable change.
NASA Astrophysics Data System (ADS)
Wu, Jianing; Yan, Shaoze; Xie, Liyang
2011-12-01
To address the impact of solar array anomalies, it is important to perform analysis of the solar array reliability. This paper establishes the fault tree analysis (FTA) and fuzzy reasoning Petri net (FRPN) models of a solar array mechanical system and analyzes reliability to find mechanisms of the solar array fault. The index final truth degree (FTD) and cosine matching function (CMF) are employed to resolve the issue of how to evaluate the importance and influence of different faults. So an improvement reliability analysis method is developed by means of the sorting of FTD and CMF. An example is analyzed using the proposed method. The analysis results show that harsh thermal environment and impact caused by particles in space are the most vital causes of the solar array fault. Furthermore, other fault modes and the corresponding improvement methods are discussed. The results reported in this paper could be useful for the spacecraft designers, particularly, in the process of redesigning the solar array and scheduling its reliability growth plan.
ERIC Educational Resources Information Center
Lung, For-Wey; Chiang, Tung-Liang; Lin, Shio-Jean; Feng, Jui-Ying; Chen, Po-Fei; Shu, Bih-Ching
2011-01-01
The parental report instrument is the most efficient developmental detection method and has shown high validity with professional assessment instruments. The reliability and validity of the Taiwan Birth Cohort Study (TBCS) 6-, 18- and 36-month scales have already been established. In this study, the reliability and validity of the 60-month scale…
NASA Astrophysics Data System (ADS)
Xia, Quan; Wang, Zili; Ren, Yi; Sun, Bo; Yang, Dezhen; Feng, Qiang
2018-05-01
With the rapid development of lithium-ion battery technology in the electric vehicle (EV) industry, the lifetime of the battery cell increases substantially; however, the reliability of the battery pack is still inadequate. Because of the complexity of the battery pack, a reliability design method for a lithium-ion battery pack considering the thermal disequilibrium is proposed in this paper based on cell redundancy. Based on this method, a three-dimensional electric-thermal-flow-coupled model, a stochastic degradation model of cells under field dynamic conditions and a multi-state system reliability model of a battery pack are established. The relationships between the multi-physics coupling model, the degradation model and the system reliability model are first constructed to analyze the reliability of the battery pack and followed by analysis examples with different redundancy strategies. By comparing the reliability of battery packs of different redundant cell numbers and configurations, several conclusions for the redundancy strategy are obtained. More notably, the reliability does not monotonically increase with the number of redundant cells for the thermal disequilibrium effects. In this work, the reliability of a 6 × 5 parallel-series configuration is the optimal system structure. In addition, the effect of the cell arrangement and cooling conditions are investigated.
Design and Implementation of Secure and Reliable Communication using Optical Wireless Communication
NASA Astrophysics Data System (ADS)
Saadi, Muhammad; Bajpai, Ambar; Zhao, Yan; Sangwongngam, Paramin; Wuttisittikulkij, Lunchakorn
2014-11-01
Wireless networking intensify the tractability in the home and office environment to connect the internet without wires but at the cost of risks associated with stealing the data or threat of loading malicious code with the intention of harming the network. In this paper, we proposed a novel method of establishing a secure and reliable communication link using optical wireless communication (OWC). For security, spatial diversity based transmission using two optical transmitters is used and the reliability in the link is achieved by a newly proposed method for the construction of structured parity check matrix for binary Low Density Parity Check (LDPC) codes. Experimental results show that a successful secure and reliable link between the transmitter and the receiver can be achieved by using the proposed novel technique.
Lo, Brian K C; Minaker, Leia; Chan, Alicia N T; Hrgetic, Jessica; Mah, Catherine L
2016-03-01
To adapt and validate a survey instrument to assess the nutrition environment of grab-and-go establishments at a university campus. A version of the Nutrition Environment Measures Survey for grab-and-go establishments (NEMS-GG) was adapted from existing NEMS instruments and tested for reliability and validity through a cross-sectional assessment of the grab-and-go establishments at the University of Toronto. Product availability, price, and presence of nutrition information were evaluated. Cohen's kappa coefficient and intra-class correlation coefficients (ICC) were assessed for inter-rater reliability, and construct validity was assessed using the known-groups comparison method (via store scores). Fifteen grab-and-go establishments were assessed. Inter-rater reliability was high with an almost perfect agreement for availability (mean κ = 0.995) and store scores (ICC = 0.999). The tool demonstrated good face and construct validity. About half of the venues carried fruit and vegetables (46.7% and 53.3%, respectively). Regular and healthier entrée items were generally the same price. Healthier grains were cheaper than regular options. Six establishments displayed nutrition information. Establishments operated by the university's Food Services consistently scored the highest across all food premise types for nutrition signage, availability, and cost of healthier options. Health promotion strategies are needed to address availability and variety of healthier grab-and-go options in university settings.
Between-day reliability of a method for non-invasive estimation of muscle composition.
Simunič, Boštjan
2012-08-01
Tensiomyography is a method for valid and non-invasive estimation of skeletal muscle fibre type composition. The validity of selected temporal tensiomyographic measures has been well established recently; there is, however, no evidence regarding the method's between-day reliability. Therefore it is the aim of this paper to establish the between-day repeatability of tensiomyographic measures in three skeletal muscles. For three consecutive days, 10 healthy male volunteers (mean±SD: age 24.6 ± 3.0 years; height 177.9 ± 3.9 cm; weight 72.4 ± 5.2 kg) were examined in a supine position. Four temporal measures (delay, contraction, sustain, and half-relaxation time) and maximal amplitude were extracted from the displacement-time tensiomyogram. A reliability analysis was performed with calculations of bias, random error, coefficient of variation (CV), standard error of measurement, and intra-class correlation coefficient (ICC) with a 95% confidence interval. An analysis of ICC demonstrated excellent agreement (ICC were over 0.94 in 14 out of 15 tested parameters). However, lower CV was observed in half-relaxation time, presumably because of the specifics of the parameter definition itself. These data indicate that for the three muscles tested, tensiomyographic measurements were reproducible across consecutive test days. Furthermore, we indicated the most possible origin of the lowest reliability detected in half-relaxation time. Copyright © 2012 Elsevier Ltd. All rights reserved.
Cruz, Jonas P; Baldacchino, Donia R; Alquwez, Nahed
2016-06-01
Patients often resort to religious and spiritual activities to cope with physical and mental challenges. The effect of spiritual coping on overall health, adaptation and health-related quality of life among patients undergoing haemodialysis (HD) is well documented. Thus, it is essential to establish a valid and reliable instrument that can assess both the religious and non-religious coping methods in patients undergoing HD. This study aimed to assess the validity and reliability of the Spiritual Coping Strategies Scale Arabic version (SCS-A) in Saudi patients undergoing HD. A convenience sample of 60 Saudi patients undergoing HD was recruited for this descriptive, cross-sectional study. Data were collected between May and June 2015. Forward-backward translation was used to formulate the SCS-A. The SCS-A, Muslim Religiosity Scale and the Quality of Life Index Dialysis Version III were used to procure the data. Internal consistency reliability, stability reliability, factor analysis and construct validity tests were performed. Analyses were set at the 0.05 level of significance. The SCS-A showed an acceptable internal consistency and strong stability reliability over time. The EFA produced two factors (non-religious and religious coping). Satisfactory construct validity was established by the convergent and divergent validity and known-groups method. The SCS-A is a reliable and valid tool that can be used to measure the religious and non-religious coping strategies of patients undergoing HD in Saudi Arabia and other Muslim and Arabic-speaking countries. © 2016 European Dialysis and Transplant Nurses Association/European Renal Care Association.
NASA Astrophysics Data System (ADS)
Liu, Yuan; Wang, Mingqiang; Ning, Xingyao
2018-02-01
Spinning reserve (SR) should be scheduled considering the balance between economy and reliability. To address the computational intractability cursed by the computation of loss of load probability (LOLP), many probabilistic methods use simplified formulations of LOLP to improve the computational efficiency. Two tradeoffs embedded in the SR optimization model are not explicitly analyzed in these methods. In this paper, two tradeoffs including primary tradeoff and secondary tradeoff between economy and reliability in the maximum LOLP constrained unit commitment (UC) model are explored and analyzed in a small system and in IEEE-RTS System. The analysis on the two tradeoffs can help in establishing new efficient simplified LOLP formulations and new SR optimization models.
Establishment and validation of a method for multi-dose irradiation of cells in 96-well microplates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abatzoglou, Ioannis; Zois, Christos E.; Pouliliou, Stamatia
2013-02-15
Highlights: ► We established a method for multi-dose irradiation of cell cultures within a 96-well plate. ► Equations to adjust to preferable dose levels are produced and provided. ► Up to eight different dose levels can be tested in one microplate. ► This method results in fast and reliable estimation of radiation dose–response curves. -- Abstract: Microplates are useful tools in chemistry, biotechnology and molecular biology. In radiobiology research, these can be also applied to assess the effect of a certain radiation dose delivered to the whole microplate, to test radio-sensitivity, radio-sensitization or radio-protection. Whether different radiation doses can bemore » accurately applied to a single 96-well plate to further facilitate and accelerated research by one hand and spare funds on the other, is a question dealt in the current paper. Following repeated ion-chamber, TLD and radiotherapy planning dosimetry we established a method for multi-dose irradiation of cell cultures within a 96-well plate, which allows an accurate delivery of desired doses in sequential columns of the microplate. Up to eight different dose levels can be tested in one microplate. This method results in fast and reliable estimation of radiation dose–response curves.« less
Kamei, Yasuhiro; Itou, Junji; Oda, Shoji; Masui, Mami; Kim, Jin-Hyeong; Ishikawa, Tomoko; Yuba, Shunsuke; Kinoshita, Masato; Mitani, Hiroshi; Todo, Takeshi
2007-12-01
Medaka is a small Asian freshwater teleost and has been an excellent model for fertilization studies for more than 50 years. Therefore, experimental procedures for in vitro fertilization (IVF) and cryopreservation of sperm are well established. In contrast, since the eggs or early embryos can not be cryopreserved, many females are killed to obtain unfertilized eggs for IVF. Recent progress in genomics is establishing medaka as a new model animal in functional genomics, and numerous mutant and transgenic strains have been established and stored as frozen sperm. Accumulated preserved resources require a simple and reliable recovery method for IVF. In this paper, we describe a method for obtaining a large number of unfertilized eggs without killing females, using sterile interspecific hybrids between Oryzias latipes and O. curvinotus. However, there is no report about the normality of offspring that were obtained by IVF using unfertilized eggs spawned in mating with the sterile hybrid male. In this paper, we have confirmed the reliability of the method regarding the influences on the next generation and also assessed conditions for efficient collection of unfertilized eggs. The method would be useful not only for fertilization studies but also for keeping transgenics and mutants, including a mutant library for a reverse genetic approach.
Assessment of mesh simplification algorithm quality
NASA Astrophysics Data System (ADS)
Roy, Michael; Nicolier, Frederic; Foufou, S.; Truchetet, Frederic; Koschan, Andreas; Abidi, Mongi A.
2002-03-01
Traditionally, medical geneticists have employed visual inspection (anthroposcopy) to clinically evaluate dysmorphology. In the last 20 years, there has been an increasing trend towards quantitative assessment to render diagnosis of anomalies more objective and reliable. These methods have focused on direct anthropometry, using a combination of classical physical anthropology tools and new instruments tailor-made to describe craniofacial morphometry. These methods are painstaking and require that the patient remain still for extended periods of time. Most recently, semiautomated techniques (e.g., structured light scanning) have been developed to capture the geometry of the face in a matter of seconds. In this paper, we establish that direct anthropometry and structured light scanning yield reliable measurements, with remarkably high levels of inter-rater and intra-rater reliability, as well as validity (contrasting the two methods).
Hesari, Nikou; Kıratlı Yılmazçoban, Nursel; Elzein, Mohamad; Alum, Absar; Abbaszadegan, Morteza
2017-01-03
Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor method for the detection of E. coli in drinking water samples. In this study, different reagents and assay conditions including temperatures, holding time, E. coli strains and concentrations, dissolving agents, salinity and pH effects, quality of substrates of various suppliers of 4-methylumbelliferyl glucuronide (MUG), and environmental water samples were included in the QA/QC plan and used in the assay optimization and documentation. Furthermore, the procedural QA/QC for the monitoring of drinking water samples was established to validate the performance of the biosensor platform for the detection of E. coli using a culture-based standard technique. Implementing the developed QA/QC plan, the same level of precision and accuracy was achieved using both the standard and the biosensor methods. The established procedural QA/QC for the biosensor will provide a reliable tool for a near real-time monitoring of E. coli in drinking water samples to both industry and regulatory authorities.
Hesari, Nikou; Kıratlı Yılmazçoban, Nursel; Elzein, Mohamad; Alum, Absar; Abbaszadegan, Morteza
2017-01-01
Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor method for the detection of E. coli in drinking water samples. In this study, different reagents and assay conditions including temperatures, holding time, E. coli strains and concentrations, dissolving agents, salinity and pH effects, quality of substrates of various suppliers of 4-methylumbelliferyl glucuronide (MUG), and environmental water samples were included in the QA/QC plan and used in the assay optimization and documentation. Furthermore, the procedural QA/QC for the monitoring of drinking water samples was established to validate the performance of the biosensor platform for the detection of E. coli using a culture-based standard technique. Implementing the developed QA/QC plan, the same level of precision and accuracy was achieved using both the standard and the biosensor methods. The established procedural QA/QC for the biosensor will provide a reliable tool for a near real-time monitoring of E. coli in drinking water samples to both industry and regulatory authorities. PMID:28054956
ERIC Educational Resources Information Center
Furr-Holden, C. D. M.; Campbell, K. D. M.; Milam, A. J.; Smart, M. J.; Ialongo, N. A.; Leaf, P. J.
2010-01-01
Objectives: Establish metric properties of the Neighborhood Inventory for Environmental Typology (NIfETy). Method: A total of 919 residential block faces were assessed by paired raters using the NIfETy. Reliability was evaluated via interrater and internal consistency reliability; validity by comparing NIfETy data with youth self-reported…
Petrova, Tatjana; Kavookjian, Jan; Madson, Michael B; Dagley, John; Shannon, David; McDonough, Sharon K
2015-01-01
Motivational interviewing (MI) has demonstrated a significant impact as an intervention strategy for addiction management, change in lifestyle behaviors, and adherence to prescribed medication and other treatments. Key elements to studying MI include training in MI of professionals who will use it, assessment of skills acquisition in trainees, and the use of a validated skills assessment tool. The purpose of this research project was to develop a psychometrically valid and reliable tool that has been designed to assess MI skills competence in health care provider trainees. The goal was to develop an assessment tool that would evaluate the acquisition and use of specific MI skills and principles, as well as the quality of the patient-provider therapeutic alliance in brief health care encounters. To address this purpose, specific steps were followed, beginning with a literature review. This review contributed to the development of relevant conceptual and operational definitions, selecting a scaling technique and response format, and methods for analyzing validity and reliability. Internal consistency reliability was established on 88 video recorded interactions. The inter-rater and test-retest reliability were established using randomly selected 18 from the 88 interactions. The assessment tool Motivational Interviewing Skills for Health Care Encounters (MISHCE) and a manual for use of the tool were developed. Validity and reliability of MISHCE were examined. Face and content validity were supported with well-defined conceptual and operational definitions and feedback from an expert panel. Reliability was established through internal consistency, inter-rater reliability, and test-retest reliability. The overall internal consistency reliability (Cronbach's alpha) for all fifteen items was 0.75. MISHCE demonstrated good inter-rater reliability and good to excellent test-retest reliability. MISHCE assesses the health provider's level of knowledge and skills in brief disease management encounters. MISHCE also evaluates quality of the patient-provider therapeutic alliance, i.e., the "flow" of the interaction. Copyright © 2015 Elsevier Inc. All rights reserved.
Height modernization program and subsidence study in northern Ohio.
DOT National Transportation Integrated Search
2013-11-01
This study is an initiative focused on establishing accurate, reliable heights using Global Navigation Satellite System (GNSS) technology in conjunction with traditional leveling, gravity, and modern remote sensing information. The traditional method...
NASA Astrophysics Data System (ADS)
Cauquil, Jean-Marc; Seguineau, Cédric; Vasse, Christophe; Raynal, Gaetan; Benschop, Tonny
2018-05-01
The cooler reliability is a major performance requested by the customers, especially for 24h/24h applications, which are a growing market. Thales has built a reliability policy based on accelerate ageing and tests to establish a robust knowledge on acceleration factors. The current trend seems to prove that the RM2 mean time to failure is now higher than 30,000hr. Even with accelerate ageing; the reliability growth becomes hardly manageable for such large figures. The paper focuses on these figures and comments the robustness of such a method when projections over 30,000hr of MTTF are needed.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
... systems. E. Quantitative Methods for Comparing Capital Frameworks The NPR sought comment on how the... industry while assessing levels of capital. This commenter points out maintaining reliable comparative data over time could make quantitative methods for this purpose difficult. For example, evaluating asset...
Establishing even-age northern hardwood regeneration by the shelterwood method--a preliminary guide.
Richard M. Godman; Carl H. Tubbs
1973-01-01
The shelterwood system of regeneration with northern hardwoods is a reliable method of obtaining even-age stands of both tolerant and moderately tolerant species. Details of applying the two-cut system are described along with the necessary modifications for encouraging moderately tolerant species.
Doğramac, Sera N; Watsford, Mark L; Murphy, Aron J
2011-03-01
Subjective notational analysis can be used to track players and analyse movement patterns during match-play of team sports such as futsal. The purpose of this study was to establish the validity and reliability of the Event Recorder for subjective notational analysis. A course was designed, replicating ten minutes of futsal match-play movement patterns, where ten participants undertook the course. The course allowed a comparison of data derived from subjective notational analysis, to the known distances of the course, and to GPS data. The study analysed six locomotor activity categories, focusing on total distance covered, total duration of activities and total frequency of activities. The values between the known measurements and the Event Recorder were similar, whereas the majority of significant differences were found between the Event Recorder and GPS values. The reliability of subjective notational analysis was established with all ten participants being analysed on two occasions, as well as analysing five random futsal players twice during match-play. Subjective notational analysis is a valid and reliable method of tracking player movements, and may be a preferred and more effective method than GPS, particularly for indoor sports such as futsal, and field sports where short distances and changes in direction are observed.
ERIC Educational Resources Information Center
Liu, Xueman Lucy; de Villiers, Jill; Ning, Chunyan; Rolfhus, Eric; Hutchings, Teresa; Lee, Wendy; Jiang, Fan; Zhang, Yi Wen
2017-01-01
Purpose: With no existing gold standard for comparison, challenges arise for establishing the validity of a new standardized Mandarin language assessment normed in mainland China. Method: A new assessment, Diagnostic Receptive and Expressive Assessment of Mandarin (DREAM), was normed with a stratified sample of 969 children ages 2;6 (years;months)…
Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective
Shterenshis, Michael
2017-01-01
Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes. PMID:29138741
Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective.
Shterenshis, Michael
2017-01-01
Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes.
NASA Astrophysics Data System (ADS)
Lauer, Eric A.; Corner, Brian D.; Li, Peng; Beecher, Robert M.; Deutsch, Curtis
2002-03-01
Traditionally, medical geneticists have employed visual inspection (anthroposcopy) to clinically evaluate dysmorphology. In the last 20 years, there has been an increasing trend towards quantitative assessment to render diagnosis of anomalies more objective and reliable. These methods have focused on direct anthropometry, using a combination of classical physical anthropology tools and new instruments tailor-made to describe craniofacial morphometry. These methods are painstaking and require that the patient remain still for extended periods of time. Most recently, semiautomated techniques (e.g., structured light scanning) have been developed to capture the geometry of the face in a matter of seconds. In this paper, we establish that direct anthropometry and structured light scanning yield reliable measurements, with remarkably high levels of inter-rater and intra-rater reliability, as well as validity (contrasting the two methods).
NASA Astrophysics Data System (ADS)
Song, Lu-Kai; Wen, Jie; Fei, Cheng-Wei; Bai, Guang-Chen
2018-05-01
To improve the computing efficiency and precision of probabilistic design for multi-failure structure, a distributed collaborative probabilistic design method-based fuzzy neural network of regression (FR) (called as DCFRM) is proposed with the integration of distributed collaborative response surface method and fuzzy neural network regression model. The mathematical model of DCFRM is established and the probabilistic design idea with DCFRM is introduced. The probabilistic analysis of turbine blisk involving multi-failure modes (deformation failure, stress failure and strain failure) was investigated by considering fluid-structure interaction with the proposed method. The distribution characteristics, reliability degree, and sensitivity degree of each failure mode and overall failure mode on turbine blisk are obtained, which provides a useful reference for improving the performance and reliability of aeroengine. Through the comparison of methods shows that the DCFRM reshapes the probability of probabilistic analysis for multi-failure structure and improves the computing efficiency while keeping acceptable computational precision. Moreover, the proposed method offers a useful insight for reliability-based design optimization of multi-failure structure and thereby also enriches the theory and method of mechanical reliability design.
Distributed collaborative response surface method for mechanical dynamic assembly reliability design
NASA Astrophysics Data System (ADS)
Bai, Guangchen; Fei, Chengwei
2013-11-01
Because of the randomness of many impact factors influencing the dynamic assembly relationship of complex machinery, the reliability analysis of dynamic assembly relationship needs to be accomplished considering the randomness from a probabilistic perspective. To improve the accuracy and efficiency of dynamic assembly relationship reliability analysis, the mechanical dynamic assembly reliability(MDAR) theory and a distributed collaborative response surface method(DCRSM) are proposed. The mathematic model of DCRSM is established based on the quadratic response surface function, and verified by the assembly relationship reliability analysis of aeroengine high pressure turbine(HPT) blade-tip radial running clearance(BTRRC). Through the comparison of the DCRSM, traditional response surface method(RSM) and Monte Carlo Method(MCM), the results show that the DCRSM is not able to accomplish the computational task which is impossible for the other methods when the number of simulation is more than 100 000 times, but also the computational precision for the DCRSM is basically consistent with the MCM and improved by 0.40˜4.63% to the RSM, furthermore, the computational efficiency of DCRSM is up to about 188 times of the MCM and 55 times of the RSM under 10000 times simulations. The DCRSM is demonstrated to be a feasible and effective approach for markedly improving the computational efficiency and accuracy of MDAR analysis. Thus, the proposed research provides the promising theory and method for the MDAR design and optimization, and opens a novel research direction of probabilistic analysis for developing the high-performance and high-reliability of aeroengine.
Anderson, Ruth A.; Hsieh, Pi-Ching; Su, Hui Fang; Landerman, Lawrence R.; McDaniel, Reuben R.
2013-01-01
Objectives. To (1) describe participation in decision-making as a systems-level property of complex adaptive systems and (2) present empirical evidence of reliability and validity of a corresponding measure. Method. Study 1 was a mail survey of a single respondent (administrators or directors of nursing) in each of 197 nursing homes. Study 2 was a field study using random, proportionally stratified sampling procedure that included 195 organizations with 3,968 respondents. Analysis. In Study 1, we analyzed the data to reduce the number of scale items and establish initial reliability and validity. In Study 2, we strengthened the psychometric test using a large sample. Results. Results demonstrated validity and reliability of the participation in decision-making instrument (PDMI) while measuring participation of workers in two distinct job categories (RNs and CNAs). We established reliability at the organizational level aggregated items scores. We established validity of the multidimensional properties using convergent and discriminant validity and confirmatory factor analysis. Conclusions. Participation in decision making, when modeled as a systems-level property of organization, has multiple dimensions and is more complex than is being traditionally measured. Managers can use this model to form decision teams that maximize the depth and breadth of expertise needed and to foster connection among them. PMID:24349771
Anderson, Ruth A; Plowman, Donde; Corazzini, Kirsten; Hsieh, Pi-Ching; Su, Hui Fang; Landerman, Lawrence R; McDaniel, Reuben R
2013-01-01
Objectives. To (1) describe participation in decision-making as a systems-level property of complex adaptive systems and (2) present empirical evidence of reliability and validity of a corresponding measure. Method. Study 1 was a mail survey of a single respondent (administrators or directors of nursing) in each of 197 nursing homes. Study 2 was a field study using random, proportionally stratified sampling procedure that included 195 organizations with 3,968 respondents. Analysis. In Study 1, we analyzed the data to reduce the number of scale items and establish initial reliability and validity. In Study 2, we strengthened the psychometric test using a large sample. Results. Results demonstrated validity and reliability of the participation in decision-making instrument (PDMI) while measuring participation of workers in two distinct job categories (RNs and CNAs). We established reliability at the organizational level aggregated items scores. We established validity of the multidimensional properties using convergent and discriminant validity and confirmatory factor analysis. Conclusions. Participation in decision making, when modeled as a systems-level property of organization, has multiple dimensions and is more complex than is being traditionally measured. Managers can use this model to form decision teams that maximize the depth and breadth of expertise needed and to foster connection among them.
Simulation-Based Training for Colonoscopy
Preisler, Louise; Svendsen, Morten Bo Søndergaard; Nerup, Nikolaj; Svendsen, Lars Bo; Konge, Lars
2015-01-01
Abstract The aim of this study was to create simulation-based tests with credible pass/fail standards for 2 different fidelities of colonoscopy models. Only competent practitioners should perform colonoscopy. Reliable and valid simulation-based tests could be used to establish basic competency in colonoscopy before practicing on patients. Twenty-five physicians (10 consultants with endoscopic experience and 15 fellows with very little endoscopic experience) were tested on 2 different simulator models: a virtual-reality simulator and a physical model. Tests were repeated twice on each simulator model. Metrics with discriminatory ability were identified for both modalities and reliability was determined. The contrasting-groups method was used to create pass/fail standards and the consequences of these were explored. The consultants significantly performed faster and scored higher than the fellows on both the models (P < 0.001). Reliability analysis showed Cronbach α = 0.80 and 0.87 for the virtual-reality and the physical model, respectively. The established pass/fail standards failed one of the consultants (virtual-reality simulator) and allowed one fellow to pass (physical model). The 2 tested simulations-based modalities provided reliable and valid assessments of competence in colonoscopy and credible pass/fail standards were established for both the tests. We propose to use these standards in simulation-based training programs before proceeding to supervised training on patients. PMID:25634177
10 CFR 434.603 - Determination of the design energy use.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Design using the same methods, assumptions, climate data, and simulation tool as were used to establish... reliable local source. During rapid changes in fuel prices it is recommended that an average fuel price for...
10 CFR 434.603 - Determination of the design energy use.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Design using the same methods, assumptions, climate data, and simulation tool as were used to establish... reliable local source. During rapid changes in fuel prices it is recommended that an average fuel price for...
10 CFR 434.603 - Determination of the design energy use.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Design using the same methods, assumptions, climate data, and simulation tool as were used to establish... reliable local source. During rapid changes in fuel prices it is recommended that an average fuel price for...
Rapid Identification of Legionella Pathogenicity by Surface-Enhanced Raman Spectroscopy.
Li, Jing; Qin, Tian; Jia, Xiao Xiao; Deng, Ai Hua; Zhang, Xu; Fan, Wen Hui; Huo, Shuai Dong; Wen, Ting Yi; Liu, Wen Jun
2015-06-01
To establish Surface-enhanced Raman Spectroscopy (SERS) can be used as a rapid and reliable method to distinguish virulent strain and mild strain of L. pneumophila. Mortality data were collected from company departments through administrative documents, death certificates, etc. Trend analyses of cancer mortality were performed on the basis of 925 cancer deaths between 2001 and 2010. Our results indicated that the peaks of high virulence strains reached ⋝4000. This criterion was verified by subsequent cell experiments. In addition, we also conducted SERS rapid identification on the virulence of several collected clinical strains and obtained accurate results. The present study indicates that the established SERS protocol can be used as a rapid and reliable method to distinguish virulent and mildly virulent strains of L. pneumophila, which can be further used in clinical samples. Copyright © 2015 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Saffari, Mohsen; Naderi, Maryam K; Piper, Crystal N; Koenig, Harold G
There is no valid and well-established tool to measure fatigue in people with chronic hepatitis B. The aim of this study was to translate the Multidimensional Fatigue Inventory (MFI) into Persian and examine its reliability and validity in Iranian people with chronic hepatitis B. The demographic questionnaire and MFI, as well as Chronic Liver Disease Questionnaire and EuroQol-5D (to assess criterion validity), were administered in face-to-face interviews with 297 participants. A forward-backward translation method was used to develop a culturally adapted Persian version of the questionnaire. Cronbach's α was used to assess the internal reliability of the scale. Pearson correlation was used to assess criterion validity, and known-group method was used along with factor analysis to establish construct validity. Cronbach's α for the total scale was 0.89. Convergent and discriminant validities were also established. Correlations between the MFI and the health-related quality of life scales were significant (p < .01). The scale differentiated between subgroups of persons with the hepatitis B infection in terms of age, gender, employment, education, disease duration, and stage of disease. Factor analysis indicated a four-factor solution for the scale that explained 60% of the variance. The MFI is a valid and reliable instrument to identify fatigue in Iranians with hepatitis B.
ERIC Educational Resources Information Center
Rahman, Nurulhuda Abd; Masuwai, Azwani; Tajudin, Nor'ain Mohd; Tek, Ong Eng; Adnan, Mazlini
2016-01-01
Purpose: This study was aimed at establishing, through the validation of the "Teaching and Learning Guiding Principles Instrument" (TLGPI), the validity and reliability of the underlying factor structure of the Teaching and Learning Guiding Principles (TLGP) generated by a previous study. Method: A survey method was used to collect data…
ERIC Educational Resources Information Center
Lakes, Kimberley D.; Swanson, James M.; Riggs, Matt
2012-01-01
Objective: To evaluate the reliability and validity of the English and Spanish versions of the Strengths and Weaknesses of ADHD-symptom and Normal-behavior (SWAN) rating scale. Method: Parents of preschoolers completed both a SWAN and the well-established Strengths and Difficulties Questionnaire (SDQ) on two separate occasions over a span of 3…
Scherr, Karen A.; Fagerlin, Angela; Williamson, Lillie D.; Davis, J. Kelly; Fridman, Ilona; Atyeo, Natalie; Ubel, Peter A.
2016-01-01
Background Physicians’ recommendations affect patients’ treatment choices. However, most research relies on physicians’ or patients’ retrospective reports of recommendations, which offer a limited perspective and have limitations such as recall bias. Objective To develop a reliable and valid method to measure the strength of physician recommendations using direct observation of clinical encounters. Methods Clinical encounters (n = 257) were recorded as part of a larger study of prostate cancer decision making. We used an iterative process to create the 5-point Physician Recommendation Coding System (PhyReCS). To determine reliability, research assistants double-coded 50 transcripts. To establish content validity, we used one-way ANOVAs to determine whether relative treatment recommendation scores differed as a function of which treatment patients received. To establish concurrent validity, we examined whether patients’ perceived treatment recommendations matched our coded recommendations. Results The PhyReCS was highly reliable (Krippendorf’s alpha =. 89, 95% CI [.86, .91]). The average relative treatment recommendation score for each treatment was higher for individuals who received that particular treatment. For example, the average relative surgery recommendation score was higher for individuals who received surgery versus radiation (mean difference = .98, SE = .18, p < .001) or active surveillance (mean difference = 1.10, SE = .14, p < .001). Patients’ perceived recommendations matched coded recommendations 81% of the time. Conclusion The PhyReCS is a reliable and valid way to capture the strength of physician recommendations. We believe that the PhyReCS would be helpful for other researchers who wish to study physician recommendations, an important part of patient decision making. PMID:27343015
Choosing the optimal wind turbine variant using the ”ELECTRE” method
NASA Astrophysics Data System (ADS)
Ţişcă, I. A.; Anuşca, D.; Dumitrescu, C. D.
2017-08-01
This paper presents a method of choosing the “optimal” alternative, both under certainty and under uncertainty, based on relevant analysis criteria. Taking into account that a product can be assimilated to a system and that the reliability of the system depends on the reliability of its components, the choice of product (the appropriate system decision) can be done using the “ELECTRE” method and depending on the level of reliability of each product. In the paper, the “ELECTRE” method is used in choosing the optimal version of a wind turbine required to equip a wind farm in western Romania. The problems to be solved are related to the current situation of wind turbines that involves reliability problems. A set of criteria has been proposed to compare two or more products from a range of available products: Operating conditions, Environmental conditions during operation, Time requirements. Using the ELECTRE hierarchical mathematical method it was established that on the basis of the obtained coefficients of concordance the optimal variant of the wind turbine and the order of preference of the variants are determined, the values chosen as limits being arbitrary.
Code of Federal Regulations, 2011 CFR
2011-01-01
... HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the Human Reliability Program General Provisions § 712.1 Purpose. This part establishes the policies and procedures for a Human Reliability Program... judgment and reliability may be impaired by physical or mental/personality disorders, alcohol abuse, use of...
Reliability Modeling of Microelectromechanical Systems Using Neural Networks
NASA Technical Reports Server (NTRS)
Perera. J. Sebastian
2000-01-01
Microelectromechanical systems (MEMS) are a broad and rapidly expanding field that is currently receiving a great deal of attention because of the potential to significantly improve the ability to sense, analyze, and control a variety of processes, such as heating and ventilation systems, automobiles, medicine, aeronautical flight, military surveillance, weather forecasting, and space exploration. MEMS are very small and are a blend of electrical and mechanical components, with electrical and mechanical systems on one chip. This research establishes reliability estimation and prediction for MEMS devices at the conceptual design phase using neural networks. At the conceptual design phase, before devices are built and tested, traditional methods of quantifying reliability are inadequate because the device is not in existence and cannot be tested to establish the reliability distributions. A novel approach using neural networks is created to predict the overall reliability of a MEMS device based on its components and each component's attributes. The methodology begins with collecting attribute data (fabrication process, physical specifications, operating environment, property characteristics, packaging, etc.) and reliability data for many types of microengines. The data are partitioned into training data (the majority) and validation data (the remainder). A neural network is applied to the training data (both attribute and reliability); the attributes become the system inputs and reliability data (cycles to failure), the system output. After the neural network is trained with sufficient data. the validation data are used to verify the neural networks provided accurate reliability estimates. Now, the reliability of a new proposed MEMS device can be estimated by using the appropriate trained neural networks developed in this work.
Hauge, Cindy Horst; Jacobs-Knight, Jacque; Jensen, Jamie L; Burgess, Katherine M; Puumala, Susan E; Wilton, Georgiana; Hanson, Jessica D
2015-06-01
The purpose of this study was to use a mixed-methods approach to determine the validity and reliability of measurements used within an alcohol-exposed pregnancy prevention program for American Indian women. To develop validity, content experts provided input into the survey measures, and a "think aloud" methodology was conducted with 23 American Indian women. After revising the measurements based on this input, a test-retest was conducted with 79 American Indian women who were randomized to complete either the original measurements or the new, modified measurements. The test-retest revealed that some of the questions performed better for the modified version, whereas others appeared to be more reliable for the original version. The mixed-methods approach was a useful methodology for gathering feedback on survey measurements from American Indian participants and in indicating specific survey questions that needed to be modified for this population. © The Author(s) 2015.
Himle, Michael B; Chang, Susanna; Woods, Douglas W; Pearlman, Amanda; Buzzella, Brian; Bunaciu, Liviu; Piacentini, John C
2006-01-01
Behavior analysis has been at the forefront in establishing effective treatments for children and adults with chronic tic disorders. As is customary in behavior analysis, the efficacy of these treatments has been established using direct-observation assessment methods. Although behavior-analytic treatments have enjoyed acceptance and integration into mainstream health care practices for tic disorders (e.g., psychiatry and neurology), the use of direct observation as a primary assessment tool has been neglected in favor of less objective methods. Hesitation to use direct observation appears to stem largely from concerns about the generalizability of clinic observations to other settings (e.g., home) and a lack of consensus regarding the most appropriate and feasible techniques for conducting and scoring direct observation. The purpose of the current study was to evaluate and establish a reliable, valid, and feasible direct-observation protocol capable of being transported to research and clinical settings. A total of 43 children with tic disorders, collected from two outpatient specialty clinics, were assessed using direct (videotape samples) and indirect (Yale Global Tic Severity Scale; YGTSS) methods. Videotaped observation samples were collected across 3 consecutive weeks and two different settings (clinic and home), were scored using both exact frequency counts and partial-interval coding, and were compared to data from a common indirect measure of tic severity (the YGTSS). In addition, various lengths of videotaped segments were scored to determine the optimal observation length. Results show that (a) clinic-based observations correspond well to home-based observations, (b) brief direct-observation segments scored with time-sampling methods reliably quantified tics, and (c) indirect methods did not consistently correspond with the direct methods.
Research on Novel Algorithms for Smart Grid Reliability Assessment and Economic Dispatch
NASA Astrophysics Data System (ADS)
Luo, Wenjin
In this dissertation, several studies of electric power system reliability and economy assessment methods are presented. To be more precise, several algorithms in evaluating power system reliability and economy are studied. Furthermore, two novel algorithms are applied to this field and their simulation results are compared with conventional results. As the electrical power system develops towards extra high voltage, remote distance, large capacity and regional networking, the application of a number of new technique equipments and the electric market system have be gradually established, and the results caused by power cut has become more and more serious. The electrical power system needs the highest possible reliability due to its complication and security. In this dissertation the Boolean logic Driven Markov Process (BDMP) method is studied and applied to evaluate power system reliability. This approach has several benefits. It allows complex dynamic models to be defined, while maintaining its easy readability as conventional methods. This method has been applied to evaluate IEEE reliability test system. The simulation results obtained are close to IEEE experimental data which means that it could be used for future study of the system reliability. Besides reliability, modern power system is expected to be more economic. This dissertation presents a novel evolutionary algorithm named as quantum evolutionary membrane algorithm (QEPS), which combines the concept and theory of quantum-inspired evolutionary algorithm and membrane computation, to solve the economic dispatch problem in renewable power system with on land and offshore wind farms. The case derived from real data is used for simulation tests. Another conventional evolutionary algorithm is also used to solve the same problem for comparison. The experimental results show that the proposed method is quick and accurate to obtain the optimal solution which is the minimum cost for electricity supplied by wind farm system.
Binding, N; Schilder, K; Czeschinski, P A; Witting, U
1998-08-01
The 2,4-dinitrophenylhydrazine (2,4-DNPH) derivatization method mainly used for the determination of airborne formaldehyde was extended for acetaldehyde, acetone, 2-butanone, and cyclohexanone, the next four carbonyl compounds of industrial importance. Sampling devices and sampling conditions were adjusted for the respective limit value regulations. Analytical reliability criteria were established and compared to those of other recommended methods. With a minimum analytical range from one tenth to the 3-fold limit value in all cases and with relative standard deviations below 5%, the adjusted method meets all requirements for the reliable quantification of the four compounds in workplace air as well as in ambient air.
Lorencatto, Fabiana; West, Robert; Seymour, Natalie; Michie, Susan
2013-06-01
There is a difference between interventions as planned and as delivered in practice. Unless we know what was actually delivered, we cannot understand "what worked" in effective interventions. This study aimed to (a) assess whether an established taxonomy of 53 smoking cessation behavior change techniques (BCTs) may be applied or adapted as a method for reliably specifying the content of smoking cessation behavioral support consultations and (b) develop an effective method for training researchers and practitioners in the reliable application of the taxonomy. Fifteen transcripts of audio-recorded consultations delivered by England's Stop Smoking Services were coded into component BCTs using the taxonomy. Interrater reliability and potential adaptations to the taxonomy to improve coding were discussed following 3 coding waves. A coding training manual was developed through expert consensus and piloted on 10 trainees, assessing coding reliability and self-perceived competence before and after training. An average of 33 BCTs from the taxonomy were identified at least once across sessions and coding waves. Consultations contained on average 12 BCTs (range = 8-31). Average interrater reliability was high (88% agreement). The taxonomy was adapted to simplify coding by merging co-occurring BCTs and refining BCT definitions. Coding reliability and self-perceived competence significantly improved posttraining for all trainees. It is possible to apply a taxonomy to reliably identify and classify BCTs in smoking cessation behavioral support delivered in practice, and train inexperienced coders to do so reliably. This method can be used to investigate variability in provision of behavioral support across services, monitor fidelity of delivery, and identify training needs.
NASA Astrophysics Data System (ADS)
Yu, Bo; Ning, Chao-lie; Li, Bing
2017-03-01
A probabilistic framework for durability assessment of concrete structures in marine environments was proposed in terms of reliability and sensitivity analysis, which takes into account the uncertainties under the environmental, material, structural and executional conditions. A time-dependent probabilistic model of chloride ingress was established first to consider the variations in various governing parameters, such as the chloride concentration, chloride diffusion coefficient, and age factor. Then the Nataf transformation was adopted to transform the non-normal random variables from the original physical space into the independent standard Normal space. After that the durability limit state function and its gradient vector with respect to the original physical parameters were derived analytically, based on which the first-order reliability method was adopted to analyze the time-dependent reliability and parametric sensitivity of concrete structures in marine environments. The accuracy of the proposed method was verified by comparing with the second-order reliability method and the Monte Carlo simulation. Finally, the influences of environmental conditions, material properties, structural parameters and execution conditions on the time-dependent reliability of concrete structures in marine environments were also investigated. The proposed probabilistic framework can be implemented in the decision-making algorithm for the maintenance and repair of deteriorating concrete structures in marine environments.
Psychometric Properties of the Adolescent Health Concern Inventory: The Persian Version
Baheiraei, Azam; Ahmadi, Fazlollah; Foroushani, Abbas Rahimi; Ghofranipour, Fazlollah; Weiler, Robert M
2013-01-01
Objective It is important to consider the health concerns of adolescents before developing and implementing public health promotion or health education curriculum programs aimed at ameliorating priority health problems experienced by adolescents. The aim of this study was to test the psychometric properties of the original Adolescent Health Concern Inventory (AHCI) for use with an Iranian population. Methods This was a methodological study in which 50 adolescents with age range of 14-18 years were selected using convenience sampling. The translation and cultural adaptation process of The AHCI followed recognized and established guidelines. The face and content validity was established by analyzing feedback solicited from teenagers and professionals with expertise in health, sociology and psychology. Reliability was examined using test-retest and Cronbach's alpha for internal consistency reliability. Kappa and McNemar tests were used to examine test-retest reliability for each item. Results Minor cultural differences were identified and resolved during the translation process and determining the validity of the checklist. Results from Kappa and McNemar tests indicate a high degree of test-retest reliability. Internal consistency reliability as measured by Cronbach's alpha for the subscales were between 0.68 and 0.87 with total instrument reliability of 0.96 indicating considerable overall reliability. Conclusion The Persian version of the AHCI appears valid and reliable. Hence, it can be used for filling a gap in identifying the adolescents’ health concerns in the research and community settings and school health education programs in Iran to design appropriate interventions. PMID:23682249
Calhoun Thielen, C; Sadowsky, C; Vogel, L C; Taylor, H; Davidson, L; Bultman, J; Gaughan, J; Mulcahey, M J
2017-05-01
Mixed methods were used in this study. The appropriateness of the levels of the Walking Index for Spinal Cord Injury II (WISCI-II) for application in children was critically reviewed by physical therapists using the Modified Delphi Technique, and the inter- and intra-rater reliability of the WISCI-II in children was evaluated. To examine the construct validity, and to establish reliability of the WISCI-II related to its use in children with spinal cord injury (SCI). United States of America. Using a Modified Delphi Technique, physical therapists critically reviewed the WISCI-II levels for pediatric utilization. Concurrently, ambulatory children under age 18 years with SCI were evaluated using the WISCI-II on two occasions by the same therapist to establish intra-rater reliability. One trial was photographed and de-identified. Each photograph was reviewed by four different physical therapists who gave WISCI-II scores to establish inter-rater reliability. Summary and descriptive statistics were used to calculate the frequency of yes/no responses for each WISCI-II level question and to determine the percent agreement for each question. Inter- and intra-rater reliability was calculated using interclass correlation coefficients (ICCs) with 95% confidence intervals (CI). Construct validity was confirmed after one Delphi round during which at least 80% agreement was established by 51 physical therapists on the appropriateness of the WISCI-II levels for children. Fifty-two children with SCI aged 2-17 years completed repeated WISCI-II assessments and 40 de-identified photographs were scored by four physical therapists. Intra- and inter-rater reliability was high (ICC=0.997, CI=0.995-0.998 and ICC=0.97, CI=0.95-0.98, respectively). This study demonstrates support for the use of the WISCI-II in ambulatory children with SCI. This study was funded by the Craig H Neilsen Foundation, Spinal Cord Injury Research on the Translation Spectrum, Senior Research Award #282592 (Mulcahey, PI).
The Scorer Reliability of Self-Scored Interest Inventories.
ERIC Educational Resources Information Center
O'Shea, Arthur J.; Harrington, Thomas F.
1980-01-01
Describes the procedures the authors of the System for Career Decision-Making (CDM) followed in establishing client scoring reliability. Authors recommend that manuals of self-scored inventories provide data establishing scorer reliability, that scoring be supervised, and that APGA test standards deal directly with scorer reliability. (Author)
Jayaprakash, Paul T
2015-01-01
Establishing identification during skull-photo superimposition relies on correlating the salient morphological features of an unidentified skull with those of a face-image of a suspected dead individual using image overlay processes. Technical progression in the process of overlay has included the incorporation of video cameras, image-mixing devices and software that enables real-time vision-mixing. Conceptual transitions occur in the superimposition methods that involve 'life-size' images, that achieve orientation of the skull to the posture of the face in the photograph and that assess the extent of match. A recent report on the reliability of identification using the superimposition method adopted the currently prevalent methods and suggested an increased rate of failures when skulls were compared with related and unrelated face images. The reported reduction in the reliability of the superimposition method prompted a review of the transition in the concepts that are involved in skull-photo superimposition. The prevalent popular methods for visualizing the superimposed images at less than 'life-size', overlaying skull-face images by relying on the cranial and facial landmarks in the frontal plane when orienting the skull for matching and evaluating the match on a morphological basis by relying on mix-mode alone are the major departures in the methodology that may have reduced the identification reliability. The need to reassess the reliability of the method that incorporates the concepts which have been considered appropriate by the practitioners is stressed. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Fei, Cheng-Wei; Bai, Guang-Chen
2014-12-01
To improve the computational precision and efficiency of probabilistic design for mechanical dynamic assembly like the blade-tip radial running clearance (BTRRC) of gas turbine, a distribution collaborative probabilistic design method-based support vector machine of regression (SR)(called as DCSRM) is proposed by integrating distribution collaborative response surface method and support vector machine regression model. The mathematical model of DCSRM is established and the probabilistic design idea of DCSRM is introduced. The dynamic assembly probabilistic design of aeroengine high-pressure turbine (HPT) BTRRC is accomplished to verify the proposed DCSRM. The analysis results reveal that the optimal static blade-tip clearance of HPT is gained for designing BTRRC, and improving the performance and reliability of aeroengine. The comparison of methods shows that the DCSRM has high computational accuracy and high computational efficiency in BTRRC probabilistic analysis. The present research offers an effective way for the reliability design of mechanical dynamic assembly and enriches mechanical reliability theory and method.
White, Sarah A; van den Broek, Nynke R
2004-05-30
Before introducing a new measurement tool it is necessary to evaluate its performance. Several statistical methods have been developed, or used, to evaluate the reliability and validity of a new assessment method in such circumstances. In this paper we review some commonly used methods. Data from a study that was conducted to evaluate the usefulness of a specific measurement tool (the WHO Colour Scale) is then used to illustrate the application of these methods. The WHO Colour Scale was developed under the auspices of the WHO to provide a simple portable and reliable method of detecting anaemia. This Colour Scale is a discrete interval scale, whereas the actual haemoglobin values it is used to estimate are on a continuous interval scale and can be measured accurately using electrical laboratory equipment. The methods we consider are: linear regression, correlation coefficients, paired t-tests plotting differences against mean values and deriving limits of agreement; kappa and weighted kappa statistics, sensitivity and specificity, an intraclass correlation coefficient and the repeatability coefficient. We note that although the definition and properties of each of these methods is well established inappropriate methods continue to be used in medical literature for assessing reliability and validity, as evidenced in the context of the evaluation of the WHO Colour Scale. Copyright 2004 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Simelane-Mnisi, Sibongile; Mji, Andile
2017-01-01
Introduction: The Approaches and Study Skills Inventory for Students (ASSIST Short Version) was used to better understand the students' approaches to learning in a mathematics classes. Method: Quantitave method was used in this study. Participants were 345 first and second year mathematics students from a university in the Gauteng province of…
Validity and Reliability Study of the Korean Tinetti Mobility Test for Parkinson's Disease.
Park, Jinse; Koh, Seong-Beom; Kim, Hee Jin; Oh, Eungseok; Kim, Joong-Seok; Yun, Ji Young; Kwon, Do-Young; Kim, Younsoo; Kim, Ji Seon; Kwon, Kyum-Yil; Park, Jeong-Ho; Youn, Jinyoung; Jang, Wooyoung
2018-01-01
Postural instability and gait disturbance are the cardinal symptoms associated with falling among patients with Parkinson's disease (PD). The Tinetti mobility test (TMT) is a well-established measurement tool used to predict falls among elderly people. However, the TMT has not been established or widely used among PD patients in Korea. The purpose of this study was to evaluate the reliability and validity of the Korean version of the TMT for PD patients. Twenty-four patients diagnosed with PD were enrolled in this study. For the interrater reliability test, thirteen clinicians scored the TMT after watching a video clip. We also used the test-retest method to determine intrarater reliability. For concurrent validation, the unified Parkinson's disease rating scale, Hoehn and Yahr staging, Berg Balance Scale, Timed-Up and Go test, 10-m walk test, and gait analysis by three-dimensional motion capture were also used. We analyzed receiver operating characteristic curve to predict falling. The interrater reliability and intrarater reliability of the Korean Tinetti balance scale were 0.97 and 0.98, respectively. The interrater reliability and intra-rater reliability of the Korean Tinetti gait scale were 0.94 and 0.96, respectively. The Korean TMT scores were significantly correlated with the other clinical scales and three-dimensional motion capture. The cutoff values for predicting falling were 14 points (balance subscale) and 10 points (gait subscale). We found that the Korean version of the TMT showed excellent validity and reliability for gait and balance and had high sensitivity and specificity for predicting falls among patients with PD.
Poulos, Natalie S; Pasch, Keryn E
2015-07-01
Few studies of the food environment have collected primary data, and even fewer have reported reliability of the tool used. This study focused on the development of an innovative electronic data collection tool used to document outdoor food and beverage (FB) advertising and establishments near 43 middle and high schools in the Outdoor MEDIA Study. Tool development used GIS based mapping, an electronic data collection form on handheld devices, and an easily adaptable interface to efficiently collect primary data within the food environment. For the reliability study, two teams of data collectors documented all FB advertising and establishments within one half-mile of six middle schools. Inter-rater reliability was calculated overall and by advertisement or establishment category using percent agreement. A total of 824 advertisements (n=233), establishment advertisements (n=499), and establishments (n=92) were documented (range=8-229 per school). Overall inter-rater reliability of the developed tool ranged from 69-89% for advertisements and establishments. Results suggest that the developed tool is highly reliable and effective for documenting the outdoor FB environment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Poulos, Natalie S.; Pasch, Keryn E.
2015-01-01
Few studies of the food environment have collected primary data, and even fewer have reported reliability of the tool used. This study focused on the development of an innovative electronic data collection tool used to document outdoor food and beverage (FB) advertising and establishments near 43 middle and high schools in the Outdoor MEDIA Study. Tool development used GIS based mapping, an electronic data collection form on handheld devices, and an easily adaptable interface to efficiently collect primary data within the food environment. For the reliability study, two teams of data collectors documented all FB advertising and establishments within one half-mile of six middle schools. Inter-rater reliability was calculated overall and by advertisement or establishment category using percent agreement. A total of 824 advertisements (n=233), establishment advertisements (n=499), and establishments (n=92) were documented (range=8–229 per school). Overall inter-rater reliability of the developed tool ranged from 69–89% for advertisements and establishments. Results suggest that the developed tool is highly reliable and effective for documenting the outdoor FB environment. PMID:26022774
NASA Astrophysics Data System (ADS)
Abdenov, A. Zh; Trushin, V. A.; Abdenova, G. A.
2018-01-01
The paper considers the questions of filling the relevant SIEM nodes based on calculations of objective assessments in order to improve the reliability of subjective expert assessments. The proposed methodology is necessary for the most accurate security risk assessment of information systems. This technique is also intended for the purpose of establishing real-time operational information protection in the enterprise information systems. Risk calculations are based on objective estimates of the adverse events implementation probabilities, predictions of the damage magnitude from information security violations. Calculations of objective assessments are necessary to increase the reliability of the proposed expert assessments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kanjilal, Oindrila, E-mail: oindrila@civil.iisc.ernet.in; Manohar, C.S., E-mail: manohar@civil.iisc.ernet.in
The study considers the problem of simulation based time variant reliability analysis of nonlinear randomly excited dynamical systems. Attention is focused on importance sampling strategies based on the application of Girsanov's transformation method. Controls which minimize the distance function, as in the first order reliability method (FORM), are shown to minimize a bound on the sampling variance of the estimator for the probability of failure. Two schemes based on the application of calculus of variations for selecting control signals are proposed: the first obtains the control force as the solution of a two-point nonlinear boundary value problem, and, the secondmore » explores the application of the Volterra series in characterizing the controls. The relative merits of these schemes, vis-à-vis the method based on ideas from the FORM, are discussed. Illustrative examples, involving archetypal single degree of freedom (dof) nonlinear oscillators, and a multi-degree of freedom nonlinear dynamical system, are presented. The credentials of the proposed procedures are established by comparing the solutions with pertinent results from direct Monte Carlo simulations. - Highlights: • The distance minimizing control forces minimize a bound on the sampling variance. • Establishing Girsanov controls via solution of a two-point boundary value problem. • Girsanov controls via Volterra's series representation for the transfer functions.« less
Reliability of temporal summation and diffuse noxious inhibitory control
Cathcart, Stuart; Winefield, Anthony H; Rolan, Paul; Lushington, Kurt
2009-01-01
BACKGROUND: The test-retest reliability of temporal summation (TS) and diffuse noxious inhibitory control (DNIC) has not been reported to date. Establishing such reliability would support the possibility of future experimental studies examining factors affecting TS and DNIC. Similarly, the use of manual algometry to induce TS, or an occlusion cuff to induce DNIC of TS to mechanical stimuli, has not been reported to date. Such devices may offer a simpler method than current techniques for inducing TS and DNIC, affording assessment at more anatomical locations and in more varied research settings. METHOD: The present study assessed the test-retest reliability of TS and DNIC using the above techniques. Sex differences on these measures were also investigated. RESULTS: Repeated measures ANOVA indicated successful induction of TS and DNIC, with no significant differences across test-retest occasions. Sex effects were not significant for any measure or interaction. Intraclass correlations indicated high test-retest reliability for all measures; however, there was large interindividual variation between test and retest measurements. CONCLUSION: The present results indicate acceptable within-session test-retest reliability of TS and DNIC. The results support the possibility of future experimental studies examining factors affecting TS and DNIC. PMID:20011713
NASA Astrophysics Data System (ADS)
Teves, André da Costa; Lima, Cícero Ribeiro de; Passaro, Angelo; Silva, Emílio Carlos Nelli
2017-03-01
Electrostatic or capacitive accelerometers are among the highest volume microelectromechanical systems (MEMS) products nowadays. The design of such devices is a complex task, since they depend on many performance requirements, which are often conflicting. Therefore, optimization techniques are often used in the design stage of these MEMS devices. Because of problems with reliability, the technology of MEMS is not yet well established. Thus, in this work, size optimization is combined with the reliability-based design optimization (RBDO) method to improve the performance of accelerometers. To account for uncertainties in the dimensions and material properties of these devices, the first order reliability method is applied to calculate the probabilities involved in the RBDO formulation. Practical examples of bulk-type capacitive accelerometer designs are presented and discussed to evaluate the potential of the implemented RBDO solver.
Climate Change Impacts and Vulnerability Assessment in Industrial Complexes
NASA Astrophysics Data System (ADS)
Lee, H. J.; Lee, D. K.
2016-12-01
Climate change has recently caused frequent natural disasters, such as floods, droughts, and heat waves. Such disasters have also increased industrial damages. We must establish climate change adaptation policies to reduce the industrial damages. It is important to make accurate vulnerability assessment to establish climate change adaptation policies. Thus, this study aims at establishing a new index to assess vulnerability level in industrial complexes. Most vulnerability indices have been developed with subjective approaches, such as the Delphi survey and the Analytic Hierarchy Process(AHP). The subjective approaches rely on the knowledge of a few experts, which provokes the lack of the reliability of the indices. To alleviate the problem, we have designed a vulnerability index incorporating objective approaches. We have investigated 42 industrial complex sites in Republic of Korea (ROK). To calculate weights of variables, we used entropy method as an objective method integrating the Delphi survey as a subjective method. Finally, we found our method integrating both subjective method and objective method could generate result. The integration of the entropy method enables us to assess the vulnerability objectively. Our method will be useful to establish climate change adaptation policies by reducing the uncertainties of the methods based on the subjective approaches.
NASA Astrophysics Data System (ADS)
Xiang, Zhaowei; Yin, Ming; Dong, Guanhua; Mei, Xiaoqin; Yin, Guofu
2018-06-01
A finite element model considering volume shrinkage with powder-to-dense process of powder layer in selective laser melting (SLM) is established. Comparison between models that consider and do not consider volume shrinkage or powder-to-dense process is carried out. Further, parametric analysis of laser power and scan speed is conducted and the reliability of linear energy density as a design parameter is investigated. The results show that the established model is an effective method and has better accuracy allowing for the temperature distribution, and the length and depth of molten pool. The maximum temperature is more sensitive to laser power than scan speed. The maximum heating rate and cooling rate increase with increasing scan speed at constant laser power and increase with increasing laser power at constant scan speed as well. The simulation results and experimental result reveal that linear energy density is not always reliable using as a design parameter in the SLM.
NASA Astrophysics Data System (ADS)
Kuschenerus, Mieke; Cullen, Robert
2016-08-01
To ensure reliability and precision of wave height estimates for future satellite altimetry missions such as Sentinel 6, reliable parameter retrieval algorithms that can extract significant wave heights up to 20 m have to be established. The retrieved parameters, i.e. the retrieval methods need to be validated extensively on a wide range of possible significant wave heights. Although current missions require wave height retrievals up to 20 m, there is little evidence of systematic validation of parameter retrieval methods for sea states with wave heights above 10 m. This paper provides a definition of a set of simulated sea states with significant wave height up to 20 m, that allow simulation of radar altimeter response echoes for extreme sea states in SAR and low resolution mode. The simulated radar responses are used to derive significant wave height estimates, which can be compared with the initial models, allowing precision estimations of the applied parameter retrieval methods. Thus we establish a validation method for significant wave height retrieval for sea states causing high significant wave heights, to allow improved understanding and planning of future satellite altimetry mission validation.
Enrichment of Female Germline Stem Cells from Mouse Ovaries Using the Differential Adhesion Method.
Wu, Meng; Xiong, Jiaqiang; Ma, Lingwei; Lu, Zhiyong; Qin, Xian; Luo, Aiyue; Zhang, Jinjin; Xie, Huan; Shen, Wei; Wang, Shixuan
2018-04-28
The isolation and establishment of female germline stem cells (FGSCs) is controversial because of questions regarding the reliability and stability of the isolation method using antibody targeting mouse vasa homologue (MVH), and the molecular mechanism of FGSCs self-renewal remains unclear. Thus, there needs to be a simple and reliable method for sorting FGSCs to study them. We applied the differential adhesion method to enrich FGSCs (DA-FGSCs) from mouse ovaries. Through four rounds of purification and 7-9 subsequent passages, DA-FGSC lines were established. In addition, we assessed the role of the phosphoinositide-3 kinase (PI3K)-AKT pathway in regulating FGSC self-renewal. The obtained DA-FGSCs spontaneously differentiated into oocyte-like cells in vitro and formed functional eggs in vivo that were fertilized and produced healthy offspring. AKT was rapidly phosphorylated when the proliferation rate of FGSCs increased after 10 passages, and the addition of a chemical PI3K inhibitor prevented FGSCs self-renewal. Furthermore, over-expression of AKT-induced proliferation and differentiation of FGSCs, c-Myc, Oct-4 and Gdf-9 levels were increased. The differential adhesion method provides a more feasible approach and is an easier procedure to establish FGSC lines than traditional methods. The AKT pathway plays an important role in regulation of the proliferation and maintenance of FGSCs. These findings could help promote stem cell studies and provide a better understanding of causes of ovarian infertility, thereby providing potential treatments for infertility. © 2018 The Author(s). Published by S. Karger AG, Basel.
Kenyon, Lisa K.; Elliott, James M; Cheng, M. Samuel
2016-01-01
Purpose/Background Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. Methods A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts’ USA-Gymnastics competitive level to calculate the coefficient of determination (r2). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. Results The relationship between total MGFMT scores and subjects’ current USA-Gymnastics competitive level was found to be good (r2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). Conclusions The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level of Evidence Level 3 PMID:27999723
Kvistgaard Olsen, Jack; Fener, Dilay Kesgin; Waehrens, Eva Elisabet; Wulf Christensen, Anton; Jespersen, Anders; Danneskiold-Samsøe, Bente; Bartels, Else Marie
2017-07-01
Computerized pneumatic cuff pressure algometry (CPA) using the DoloCuff is a new method for pain assessment. Intra- and inter-rater reliabilities have not yet been established. Our aim was to examine the inter- and intrarater reliabilities of DoloCuff measures in healthy subjects. Twenty healthy subjects (ages 20 to 29 years) were assessed three times at 24-hour intervals by two trained raters. Inter-rater reliability was established based on the first and second assessments, whereas intrarater reliability was based on the second and third assessments. Subjects were randomized 1:1 to first assessment at either rater 1 or rater 2. The variables of interest were pressure pain threshold (PT), pressure pain tolerance (PTol), and temporal summation index (TSI). Reliability was estimated by a two-way mixed intraclass correlation coefficient (ICC) absolute agreement analysis. Reliability was considered excellent if ICC > 0.75, fair to good if 0.4 < ICC < 0.75, and poor if ICC < 0.4. Bias and random errors between raters and assessments were evaluated using 95% confidence interval (CI) and Bland-Altman plots. Inter-rater reliability for PT, PTol, and TSI was 0.88 (95% CI: 0.69 to 0.95), 0.86 (95% CI: 0.65 to 0.95), and 0.81 (95% CI: 0.42 to 0.94), respectively. The intrarater reliability for PT, PTol, and TSI was 0.81 (95% CI: 0.53 to 0.92), 0.89 (95% CI: 0.74 to 0.96), and 0.75 (95% CI: 0.28 to 0.91), respectively. Inter-rater reliability was excellent for PT, PTol, and TSI. Similarly, the intrarater reliability for PT and PTol was excellent, while borderline excellent/good for TSI. Therefore, the DoloCuff can be used to obtain reliable measures of pressure pain parameters in healthy subjects. © 2016 World Institute of Pain.
Identifying and classifying hyperostosis frontalis interna via computerized tomography.
May, Hila; Peled, Nathan; Dar, Gali; Hay, Ori; Abbas, Janan; Masharawi, Youssef; Hershkovitz, Israel
2010-12-01
The aim of this study was to recognize the radiological characteristics of hyperostosis frontalis interna (HFI) and to establish a valid and reliable method for its identification and classification. A reliability test was carried out on 27 individuals who had undergone a head computerized tomography (CT) scan. Intra-observer reliability was obtained by examining the images three times, by the same researcher, with a 2-week interval between each sample ranking. The inter-observer test was performed by three independent researchers. A validity test was carried out using two methods for identifying and classifying HFI: 46 cadaver skullcaps were ranked twice via computerized tomography scans and then by direct observation. Reliability and validity were calculated using Kappa test (SPSS 15.0). Reliability tests of ranking HFI via CT scans demonstrated good results (K > 0.7). As for validity, a very good consensus was obtained between the CT and direct observation, when moderate and advanced types of HFI were present (K = 0.82). The suggested classification method for HFI, using CT, demonstrated a sensitivity of 84%, specificity of 90.5%, and positive predictive value of 91.3%. In conclusion, volume rendering is a reliable and valid tool for identifying HFI. The suggested three-scale classification is most suitable for radiological diagnosis of the phenomena. Considering the increasing awareness of HFI as an early indicator of a developing malady, this study may assist radiologists in identifying and classifying the phenomena.
[Determination of aluminium in flour foods with photometric method].
Ma, Lan; Zhao, Xin; Zhou, Shuang; Yang, Dajin
2012-05-01
To establish a determination method for aluminium in flour foods with photometric method. After samples being treated with microwave digestion and wet digestion, aluminium in staple flour foods was determined by photometric method. There was a good linearity of the result in the range of 0.25 - 5.0 microg/ml aluminium, r = 0.9998; limit of detection (LOD) : 2.3 ng/ml; limit of quantitation (LOQ) : 7 ng/ml. This method of determining aluminium in flour foods is simple, rapid and reliable.
Establishing Reliability and Validity of the Criterion Referenced Exam of GeoloGy Standards EGGS
NASA Astrophysics Data System (ADS)
Guffey, S. K.; Slater, S. J.; Slater, T. F.; Schleigh, S.; Burrows, A. C.
2016-12-01
Discipline-based geoscience education researchers have considerable need for a criterion-referenced, easy-to-administer and -score conceptual diagnostic survey for undergraduates taking introductory science survey courses in order for faculty to better be able to monitor the learning impacts of various interactive teaching approaches. To support ongoing education research across the geosciences, we are continuing to rigorously and systematically work to firmly establish the reliability and validity of the recently released Exam of GeoloGy Standards, EGGS. In educational testing, reliability refers to the consistency or stability of test scores whereas validity refers to the accuracy of the inferences or interpretations one makes from test scores. There are several types of reliability measures being applied to the iterative refinement of the EGGS survey, including test-retest, alternate form, split-half, internal consistency, and interrater reliability measures. EGGS rates strongly on most measures of reliability. For one, Cronbach's alpha provides a quantitative index indicating the extent to which if students are answering items consistently throughout the test and measures inter-item correlations. Traditional item analysis methods further establish the degree to which a particular item is reliably assessing students is actually quantifiable, including item difficulty and item discrimination. Validity, on the other hand, is perhaps best described by the word accuracy. For example, content validity is the to extent to which a measurement reflects the specific intended domain of the content, stemming from judgments of people who are either experts in the testing of that particular content area or are content experts. Perhaps more importantly, face validity is a judgement of how representative an instrument is reflective of the science "at face value" and refers to the extent to which a test appears to measure a the targeted scientific domain as viewed by laypersons, examinees, test users, the public, and other invested stakeholders.
Gu, Zhi-rong; Wang, Ya-li; Sun, Yu-jing; Dind, Jun-xia
2014-09-01
To investigate the establishment and application methods of entropy-weight TOPSIS model in synthetical quality evaluation of traditional Chinese medicine with Angelica sinensis growing in Gansu Province as an example. The contents of ferulic acid, 3-butylphthalide, Z-butylidenephthalide, Z-ligustilide, linolic acid, volatile oil, and ethanol soluble extractive were used as an evaluation index set. The weights of each evaluation index were determined by information entropy method. The entropyweight TOPSIS model was established to synthetically evaluate the quality of Angelica sinensis growing in Gansu Province by Euclid closeness degree. The results based on established model were in line with the daodi meaning and the knowledge of clinical experience. The established model was simple in calculation, objective, reliable, and can be applied to synthetical quality evaluation of traditional Chinese medicine.
Mousavi, Seyed Mohammad Hadi; Dargahi, Hossein; Mohammadi, Sara
2016-10-01
Creating a safe of health care system requires the establishment of High Reliability Organizations (HROs), which reduces errors, and increases the level of safety in hospitals. This model focuses on improving reliability through higher process design, building a culture of accreditation, and leveraging human factors. The present study intends to determine the readiness of hospitals for the establishment of HROs model in Tehran University of Medical Sciences from the viewpoint of managers of these hospitals. This is a descriptive-analytical study carried out in 2013-2014. The research population consists of 105 senior and middle managers of 15 hospitals of Tehran University of Medical Sciences. The data collection tool was a 55-question researcher-made questionnaire, included six elements of HROs to assess the level of readiness for establishing HROS model from managers' point of view. The validity of the questionnaire was calculated through the content validity method using 10 experts in the area of hospitals' accreditation, and its reliability was calculated through test-retest method with a correlation coefficient of 0.90. The response rate was 90 percent. The Likert scale was used for the questions, and data analysis was conducted through SPSS version 21 Descriptive statistics was presented via tables and normal distributions of data and means. Analytical methods, including t-test, Mann-Whitney, Spearman, and Kruskal-Wallis, were used for presenting inferential statistics. The study showed that from the viewpoint of senior and middle managers of the hospitals considered in this study, these hospitals are indeed ready for acceptance and establishment of HROs model. A significant relationship was showed between HROs model and its elements with demographic details of managers like their age, work experience, management experience, and level of management. Although the studied hospitals, as viewed by their managers, are capable of attaining the goals of HROs, it seems there are a lot of challenges in this way. Therefore, it is suggested that a detailed audit is conducted among hospitals' current status regarding different characteristics of HROs, and workshops are held for medical and non-medical employees and managers of hospitals as an influencing factor; and a re-assessment process afterward, can help moving the hospitals from their current position towards an HROs culture.
Lee, Hoe C.; Yanting Chee, Derserri; Selander, Helena; Falkmer, Torbjorn
2012-01-01
Background Current methods of determining licence retainment or cancellation is through on-road driving tests. Previous research has shown that occupational therapists frequently assess drivers’ visual attention while sitting in the back seat on the opposite side of the driver. Since the eyes of the driver are not always visible, assessment by eye contact becomes problematic. Such procedural drawbacks may challenge validity and reliability of the visual attention assessments. In terms of correctly classified attention, the aim of the study was to establish the accuracy and the inter-rater reliability of driving assessments of visual attention from the back seat. Furthermore, by establishing eye contact between the assessor and the driver through an additional mirror on the wind screen, the present study aimed to establish how much such an intervention would enhance the accuracy of the visual attention assessment. Methods Two drivers with Parkinson's disease (PD) and six control drivers drove a fixed route in a driving simulator while wearing a head mounted eye tracker. The eye tracker data showed where the foveal visual attention actually was directed. These data were time stamped and compared with the simultaneous manual scoring of the visual attention of the drivers. In four of the drivers, one with Parkinson's disease, a mirror on the windscreen was set up to arrange for eye contact between the driver and the assessor. Inter-rater reliability was performed with one of the Parkinson drivers driving, but without the mirror. Results Without mirror, the overall accuracy was 56% when assessing the three control drivers and with mirror 83%. However, for the PD driver without mirror the accuracy was 94%, whereas for the PD driver with a mirror the accuracy was 90%. With respect to the inter-rater reliability, a 73% agreement was found. Conclusion If the final outcome of a driving assessment is dependent on the subcategory of a protocol assessing visual attention, we suggest the use of an additional mirror to establish eye contact between the assessor and the driver. The clinicians’ observations on-road should not be a standalone assessment in driving assessments. Instead, eye trackers should be employed for further analyses and correlation in cases where there is doubt about a driver's attention. PMID:22461850
Development of a Peer Teaching-Assessment Program and a Peer Observation and Evaluation Tool
Trujillo, Jennifer M.; Barr, Judith; Gonyeau, Michael; Van Amburgh, Jenny A.; Matthews, S. James; Qualters, Donna
2008-01-01
Objectives To develop a formalized, comprehensive, peer-driven teaching assessment program and a valid and reliable assessment tool. Methods A volunteer taskforce was formed and a peer-assessment program was developed using a multistep, sequential approach and the Peer Observation and Evaluation Tool (POET). A pilot study was conducted to evaluate the efficiency and practicality of the process and to establish interrater reliability of the tool. Intra-class correlation coefficients (ICC) were calculated. Results ICCs for 8 separate lectures evaluated by 2-3 observers ranged from 0.66 to 0.97, indicating good interrater reliability of the tool. Conclusion Our peer assessment program for large classroom teaching, which includes a valid and reliable evaluation tool, is comprehensive, feasible, and can be adopted by other schools of pharmacy. PMID:19325963
NASA Astrophysics Data System (ADS)
Miao, Yongchun; Kang, Rongxue; Chen, Xuefeng
2017-12-01
In recent years, with the gradual extension of reliability research, the study of production system reliability has become the hot topic in various industries. Man-machine-environment system is a complex system composed of human factors, machinery equipment and environment. The reliability of individual factor must be analyzed in order to gradually transit to the research of three-factor reliability. Meanwhile, the dynamic relationship among man-machine-environment should be considered to establish an effective blurry evaluation mechanism to truly and effectively analyze the reliability of such systems. In this paper, based on the system engineering, fuzzy theory, reliability theory, human error, environmental impact and machinery equipment failure theory, the reliabilities of human factor, machinery equipment and environment of some chemical production system were studied by the method of fuzzy evaluation. At last, the reliability of man-machine-environment system was calculated to obtain the weighted result, which indicated that the reliability value of this chemical production system was 86.29. Through the given evaluation domain it can be seen that the reliability of man-machine-environment integrated system is in a good status, and the effective measures for further improvement were proposed according to the fuzzy calculation results.
NASA Astrophysics Data System (ADS)
Sidhom, H.; Amadou, T.; Sahlaoui, H.; Braham, C.
2007-06-01
The evaluation of the degree of sensitization (DOS) to intergranular corrosion (IGC) of a commercial AISI 316L austenitic stainless steel aged at temperatures ranging from 550 °C to 800 °C during 100 to 80,000 hours was carried out using three different assessment methods. (1) The microstructural method coupled with the Strauss standard test (ASTM A262). This method establishes the kinetics of the precipitation phenomenon under different aging conditions, by transmission electronic microscope (TEM) examination of thin foils and electron diffraction. The subsequent chromium-depleted zones are characterized by X-ray microanalysis using scanning transmission electronic microscope (STEM). The superimposition of microstructural time-temperature-precipitation (TTP) and ASTM A262 time-temperature-sensitization (TTS) diagrams provides the relationship between aged microstructure and IGC. Moreover, by considering the chromium-depleted zone characteristics, sensitization and desensitization criteria could be established. (2) The electrochemical method involving the double loop-electrochemical potentiokinetic reactivation (DL-EPR) test. The operating conditions of this test were initially optimized using the experimental design method on the bases of the reliability, the selectivity, and the reproducibility of test responses for both annealed and sensitized steels. The TTS diagram of the AISI 316L stainless steel was established using this method. This diagram offers a quantitative assessment of the DOS and a possibility to appreciate the time-temperature equivalence of the IGC sensitization and desensitization. (3) The analytical method based on the chromium diffusion models. Using the IGC sensitization and desensitization criteria established by the microstructural method, numerical solving of the chromium diffusion equations leads to a calculated AISI 316L TTS diagram. Comparison of these three methods gives a clear advantage to the nondestructive DL-EPR test when it is used with its optimized operating conditions. This quantitative method is simple to perform; it is fast, reliable, economical, and presents the best ability to detect the lowest DOS to IGC. For these reasons, this method can be considered as a serious candidate for IGC checking of stainless steel components of industrial plants.
HPLC fingerprint analysis combined with chemometrics for pattern recognition of ginger.
Feng, Xu; Kong, Weijun; Wei, Jianhe; Ou-Yang, Zhen; Yang, Meihua
2014-03-01
Ginger, the fresh rhizome of Zingiber officinale Rosc. (Zingiberaceae), has been used worldwide; however, for a long time, there has been no standard approbated internationally for its quality control. To establish an efficacious and combinational method and pattern recognition technique for quality control of ginger. A simple, accurate and reliable method based on high-performance liquid chromatography with photodiode array (HPLC-PDA) detection was developed for establishing the chemical fingerprints of 10 batches of ginger from different markets in China. The method was validated in terms of precision, reproducibility and stability; and the relative standard deviations were all less than 1.57%. On the basis of this method, the fingerprints of 10 batches of ginger samples were obtained, which showed 16 common peaks. Coupled with similarity evaluation software, the similarities between each fingerprint of the sample and the simulative mean chromatogram were in the range of 0.998-1.000. Then, the chemometric techniques, including similarity analysis, hierarchical clustering analysis and principal component analysis were applied to classify the ginger samples. Consistent results were obtained to show that ginger samples could be successfully classified into two groups. This study revealed that HPLC-PDA method was simple, sensitive and reliable for fingerprint analysis, and moreover, for pattern recognition and quality control of ginger.
30 CFR 250.302 - Definitions concerning air quality.
Code of Federal Regulations, 2010 CFR
2010-07-01
... any combination of agents for which the Environmental Protection Agency (EPA) has established... by air quality modeling (or other methods determined by the Administrator of EPA to be reliable) not... control technology (BACT) means an emission limitation based on the maximum degree of reduction for each...
Networked Resources, Assessment and Collection Development
ERIC Educational Resources Information Center
Samson, Sue; Derry, Sebastian; Eggleston, Holly
2004-01-01
This project provides a critical evaluation of networked resources as they relate to the library's collection development policy, identifies areas of the curriculum not well represented, establishes a reliable method of assessing usage across all resources, and develops a framework of quantitative data for collection development decision making.
A Novel Three-Dimensional Vector Analysis of Axial Globe Position in Thyroid Eye Disease
Guo, Jie; Yuan, Yifei; Zhang, Rui; Huang, Wenhu
2017-01-01
Purpose. To define a three-dimensional (3D) vector method to describe the axial globe position in thyroid eye disease (TED). Methods. CT data from 59 patients with TED were collected and 3D images were reconstructed. A reference coordinate system was established, and the coordinates of the corneal apex and the eyeball center were calculated to obtain the globe vector EC→. The measurement reliability was evaluated. The parameters of EC→ were analyzed and compared with the results of two-dimensional (2D) CT measurement, Hertel exophthalmometry, and strabismus tests. Results. The reliability of EC→ measurement was excellent. The difference between EC→ and 2D CT measurement was significant (p = 0.003), and EC→ was more consistent with Hertel exophthalmometry than with 2D CT measurement (p < 0.001). There was no significant difference between EC→ and Hirschberg test, and a strong correlation was found between EC→ and synoptophore test. When one eye had a larger deviation angle than its fellow, its corneal apex shifted in the corresponding direction, but the shift of the eyeball center was not significant. The parameters of EC→ were almost perfectly consistent with the geometrical equation. Conclusions. The establishment of a 3D globe vector is feasible and reliable, and it could provide more information in the axial globe position. PMID:28491471
Zhou, Hao; Chen, Shun; Qi, Yulin; Wang, Mingshu; Jia, Renyong; Zhu, Dekang; Liu, Mafeng; Liu, Fei; Chen, Xiaoyue; Cheng, Anchun
2015-10-01
Real time quantitative polymerase chain reaction (RT-qPCR) based on SYBR-Green I binding is a quick, reliable, and easy method for analyzing small amounts of mRNA. Viral pathogens are recognized at the time of infection by pattern recognition receptors; thus, the inflammatory cytokines (IL1β, IL6, and IL18) and antiviral cytokines (IFNα, IFNγ) are secreted by innate immune cells and induced to respond to the pathogens. The objective of this study was to develop an effective and sensitive RT-qPCR assay for the rapid and accurate quantification of goose cytokines: IFNα, IFNγ, IL1β, IL6, and IL18. Subsequently, the established methods were employed to detect the immune response in agonist-stimulated goose spleen cells in vitro. These data indicated that the established RT-qPCR is a reliable method for determining relative gene expression. The results revealed that Imiquimod led to the significant upregulation of goose IFNα (P < 0.01), IFNγ (P < 0.01), IL1β (P < 0.01), IL6 (P < 0.01), and IL18 (P < 0.05). The established methods are important for scientific research and clinical applications, which require rapid and accurate results in a short period of time. The technique can potentially be used in the further research of goose molecular immunology, which will help us understand the interactions between hosts and pathogens. © 2015 Poultry Science Association Inc.
Analytical method for promoting process capability of shock absorption steel.
Sung, Wen-Pei; Shih, Ming-Hsiang; Chen, Kuen-Suan
2003-01-01
Mechanical properties and low cycle fatigue are two factors that must be considered in developing new type steel for shock absorption. Process capability and process control are significant factors in achieving the purpose of research and development programs. Often-used evaluation methods failed to measure process yield and process centering; so this paper uses Taguchi loss function as basis to establish an evaluation method and the steps for assessing the quality of mechanical properties and process control of an iron and steel manufacturer. The establishment of this method can serve the research and development and manufacturing industry and lay a foundation in enhancing its process control ability to select better manufacturing processes that are more reliable than decision making by using the other commonly used methods.
Direct nuclear reaction experiments for stellar nucleosynthesis
NASA Astrophysics Data System (ADS)
Cherubini, S.
2017-09-01
During the last two decades indirect methods where proposed and used in many experiments in order to measure nuclear cross sections between charged particles at stellar energies. These are among the lowest to be measured in nuclear physics. One of these methods, the Trojan Horse method, is based on the Quasi-Free reaction mechanism and has proved to be particularly flexible and reliable. It allowed for the measurement of the cross sections of various reactions of astrophysical interest using stable beams. The use and reliability of indirect methods become even more important when reactions induced by Radioactive Ion Beams are considered, given the much lower intensity generally available for these beams. The first Trojan Horse measurement of a process involving the use of a Radioactive Ion Beam dealt with the ^{18} F(p, α ^{15} O process in Nova conditions. To obtain pieces of information on this process, in particular about its cross section at Nova energies, the Trojan Horse method was applied to the ^{18} F(d, α ^{15} O)n three body reaction. In order to establish the reliability of the Trojan Horse method approach, the Treiman-Yang criterion is an important test and it will be addressed briefly in this paper.
Validity and Reliability of the School Physical Activity Environment Questionnaire
ERIC Educational Resources Information Center
Martin, Jeffrey J.; McCaughtry, Nate; Flory, Sara; Murphy, Anne; Wisdom, Kimberlydawn
2011-01-01
The goal of the current study was to establish the factor validity of the Questionnaire Assessing School Physical Activity Environment (Robertson-Wilson, Levesque, & Holden, 2007) using confirmatory factor analysis procedures. Another goal was to establish internal reliability and test-retest reliability. The confirmatory factor analysis…
Scherr, Karen A; Fagerlin, Angela; Williamson, Lillie D; Davis, J Kelly; Fridman, Ilona; Atyeo, Natalie; Ubel, Peter A
2017-01-01
Physicians' recommendations affect patients' treatment choices. However, most research relies on physicians' or patients' retrospective reports of recommendations, which offer a limited perspective and have limitations such as recall bias. To develop a reliable and valid method to measure the strength of physician recommendations using direct observation of clinical encounters. Clinical encounters (n = 257) were recorded as part of a larger study of prostate cancer decision making. We used an iterative process to create the 5-point Physician Recommendation Coding System (PhyReCS). To determine reliability, research assistants double-coded 50 transcripts. To establish content validity, we used 1-way analyses of variance to determine whether relative treatment recommendation scores differed as a function of which treatment patients received. To establish concurrent validity, we examined whether patients' perceived treatment recommendations matched our coded recommendations. The PhyReCS was highly reliable (Krippendorf's alpha = 0.89, 95% CI [0.86, 0.91]). The average relative treatment recommendation score for each treatment was higher for individuals who received that particular treatment. For example, the average relative surgery recommendation score was higher for individuals who received surgery versus radiation (mean difference = 0.98, SE = 0.18, P < 0.001) or active surveillance (mean difference = 1.10, SE = 0.14, P < 0.001). Patients' perceived recommendations matched coded recommendations 81% of the time. The PhyReCS is a reliable and valid way to capture the strength of physician recommendations. We believe that the PhyReCS would be helpful for other researchers who wish to study physician recommendations, an important part of patient decision making. © The Author(s) 2016.
Taheriyoun, Masoud; Moradinejad, Saber
2015-01-01
The reliability of a wastewater treatment plant is a critical issue when the effluent is reused or discharged to water resources. Main factors affecting the performance of the wastewater treatment plant are the variation of the influent, inherent variability in the treatment processes, deficiencies in design, mechanical equipment, and operational failures. Thus, meeting the established reuse/discharge criteria requires assessment of plant reliability. Among many techniques developed in system reliability analysis, fault tree analysis (FTA) is one of the popular and efficient methods. FTA is a top down, deductive failure analysis in which an undesired state of a system is analyzed. In this study, the problem of reliability was studied on Tehran West Town wastewater treatment plant. This plant is a conventional activated sludge process, and the effluent is reused in landscape irrigation. The fault tree diagram was established with the violation of allowable effluent BOD as the top event in the diagram, and the deficiencies of the system were identified based on the developed model. Some basic events are operator's mistake, physical damage, and design problems. The analytical method is minimal cut sets (based on numerical probability) and Monte Carlo simulation. Basic event probabilities were calculated according to available data and experts' opinions. The results showed that human factors, especially human error had a great effect on top event occurrence. The mechanical, climate, and sewer system factors were in subsequent tier. Literature shows applying FTA has been seldom used in the past wastewater treatment plant (WWTP) risk analysis studies. Thus, the developed FTA model in this study considerably improves the insight into causal failure analysis of a WWTP. It provides an efficient tool for WWTP operators and decision makers to achieve the standard limits in wastewater reuse and discharge to the environment.
2011-01-01
Background Psychometric properties include validity, reliability and sensitivity to change. Establishing the psychometric properties of an instrument which measures three-dimensional human posture are essential prior to applying it in clinical practice or research. Methods This paper reports the findings of a systematic literature review which aimed to 1) identify non-invasive three-dimensional (3D) human posture-measuring instruments; and 2) assess the quality of reporting of the methodological procedures undertaken to establish their psychometric properties, using a purpose-build critical appraisal tool. Results Seventeen instruments were identified, of which nine were supported by research into psychometric properties. Eleven and six papers respectively, reported on validity and reliability testing. Rater qualification and reference standards were generally poorly addressed, and there was variable quality reporting of rater blinding and statistical analysis. Conclusions There is a lack of current research to establish the psychometric properties of non-invasive 3D human posture-measuring instruments. PMID:21569486
Li, Jing-Jing; Gao, Qi; Liu, Zhi-Dong; Kang, Qiong-Hua; Hou, Yi-Jun; Zhang, Luo-Chuan; Hu, Xiao-Mei; Li, Jie; Zhang, Juan
2015-01-01
Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world. PMID:26488582
NASA Technical Reports Server (NTRS)
Eichenlaub, Carl T.; Harper, C. Douglas; Hird, Geoffrey
1993-01-01
Life-critical applications warrant a higher level of software reliability than has yet been achieved. Since it is not certain that traditional methods alone can provide the required ultra reliability, new methods should be examined as supplements or replacements. This paper describes a mathematical counterpart to the traditional process of empirical testing. ORA's Penelope verification system is demonstrated as a tool for evaluating the correctness of Ada software. Grady Booch's Ada calendar utility package, obtained through NASA, was specified in the Larch/Ada language. Formal verification in the Penelope environment established that many of the package's subprograms met their specifications. In other subprograms, failed attempts at verification revealed several errors that had escaped detection by testing.
Qureshi, Adnan I
2007-10-01
Imaging of head and neck vasculature continues to improve with the application of new technology. To judge the value of new technologies reported in the literature, it is imperative to develop objective standards optimized against bias and favoring statistical power and clinical relevance. A review of the existing literature identified the following items as lending scientific value to a report on imaging technology: prospective design, comparison with an accepted modality, unbiased patient selection, standardized image acquisition, blinded interpretation, and measurement of reliability. These were incorporated into a new grading scheme. Two physicians tested the new scheme and an established scheme to grade reports published in the medical literature. Inter-observer reliability for both methods was calculated using the kappa coefficient. A total of 22 reports evaluating imaging modalities for cervical internal carotid artery stenosis were identified from a literature search and graded by both schemes. Agreement between the two physicians in grading the level of scientific evidence using the new scheme was excellent (kappa coefficient: 0.93, p<0.0001). Agreement using the established scheme was less rigorous (kappa coefficient: 0.39, p<0.0001). The weighted kappa coefficients were 0.95 and 0.38 for the new and established schemes, respectively. Overall agreement was higher for the newer scheme (95% versus 64%). The new grading scheme can be used reliably to categorize the strength of scientific knowledge provided by individual studies of vascular imaging. The new method could assist clinicians and researchers in determining appropriate clinical applications of newly reported technical advances.
Assessing Lower Limb Alignment: Comparison of Standard Knee Xray vs Long Leg View
Zampogna, Biagio; Vasta, Sebastiano; Amendola, Annunziato; Uribe-Echevarria Marbach, Bastian; Gao, Yubo; Papalia, Rocco; Denaro, Vincenzo
2015-01-01
Background High tibial osteotomy (HTO) is a well-established and commonly utilized technique in medial knee osteoarthritis secondary to varus malalignment. Accurate measurement of the preoperative limb alignment, and the amount of correction required are essential when planning limb realignment surgery. The hip-knee-ankle angle (HKA) measured on a full length weightbearing (FLWB) X-ray in the standing position is considered the gold standard, since it allows for reliable and accurate measurement of the mechanical axis of the whole lower extremity. In general practice, alignment is often evaluated on standard anteroposterior weightbearing (APWB) X-rays, as the angle between the femur and tibial anatomic axis (TFa). It is, therefore, of value to establish if measuring the anatomical axis from limited APWB is an effective measure of knee alignment especially in patients undergoing osteotomy about the knee. Methods Three independent observers measured preoperative and postoperative FTa with standard method (FTa1) and with circles method (FTa2) on APWB X-ray and the HKA on FLWB X-ray at three different time-points separated by a two-week period. Intra-observer and inter-observer reliabilities and the comparison and relationship between anatomical and mechanical alignment were calculated. Results Intra- and interclass coefficients for all the three methods indicated excellent reliability, having all the values above 0.80. Using the mean of paired t-student test, the comparison of HKA versus TFa1 and TFa2 showed a statistically significant difference (p<.0001) both for the pre-operative and post-operative sets of values. The correlation between the HKA and FTal was found poor for the preoperative set (R=0.26) and fair for the postoperative one (R=0.53), while the new circles method showed a higher correlation in both the preoperative (R=0.71) and postoperative sets (R=0.79). Conclusions Intra-observer reliability was high for HKA, FTal and FTa2 on APWB x-rays in the pre- and post-operative setting. Inter-rater reliability was higher for HKA and TFa2 compared to FTal. The femoro-tibial angle as measured on APWB with the traditional method (FTal) has a weak correlation with the HKA, and based on these findings, should not be used in everyday practice. The FTa2 showed better correlation with the HKA, although not excellent Level of Evidence Level III, Retrospective study. PMID:26361444
Designing a Pedagogical Model for Web Engineering Education: An Evolutionary Perspective
ERIC Educational Resources Information Center
Hadjerrouit, Said
2005-01-01
In contrast to software engineering, which relies on relatively well established development approaches, there is a lack of a proven methodology that guides Web engineers in building reliable and effective Web-based systems. Currently, Web engineering lacks process models, architectures, suitable techniques and methods, quality assurance, and a…
Using Embedded Visual Coding to Support Contextualization of Historical Texts
ERIC Educational Resources Information Center
Baron, Christine
2016-01-01
This mixed-method study examines the think-aloud protocols of 48 randomly assigned undergraduate students to understand what effect embedding a visual coding system, based on reliable visual cues for establishing historical time period, would have on novice history students' ability to contextualize historic documents. Results indicate that using…
Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowl...
Physical Activity Measurement Methods for Young Children: A Comparative Study
ERIC Educational Resources Information Center
Hands, Beth; Parker, Helen; Larkin, Dawne
2006-01-01
Many behavior patterns that impact on physical activity experiences are established in early childhood, therefore it is important that valid, reliable, and feasible measures are constructed to identify children who are not developing appropriate and healthy activity habits. In this study, measures of physical activity derived by accelerometry and…
National audit of continence care: laying the foundation.
Mian, Sarah; Wagg, Adrian; Irwin, Penny; Lowe, Derek; Potter, Jonathan; Pearson, Michael
2005-12-01
National audit provides a basis for establishing performance against national standards, benchmarking against other service providers and improving standards of care. For effective audit, clinical indicators are required that are valid, feasible to apply and reliable. This study describes the methods used to develop clinical indicators of continence care in preparation for a national audit. To describe the methods used to develop and test clinical indicators of continence care with regard to validity, feasibility and reliability. A multidisciplinary working group developed clinical indicators that measured the structure, process and outcome of care as well as case-mix variables. Literature searching, consensus workshops and a Delphi process were used to develop the indicators. The indicators were tested in 15 secondary care sites, 15 primary care sites and 15 long-term care settings. The process of development produced indicators that received a high degree of consensus within the Delphi process. Testing of the indicators demonstrated an internal reliability of 0.7 and an external reliability of 0.6. Data collection required significant investment in terms of staff time and training. The method used produced indicators that achieved a high degree of acceptance from health care professionals. The reliability of data collection was high for this audit and was similar to the level seen in other successful national audits. Data collection for the indicators was feasible to collect, however, issues of time and staffing were identified as limitations to such data collection. The study has described a systematic method for developing clinical indicators for national audit. The indicators proved robust and reliable in primary and secondary care as well as long-term care settings.
Sawchuk, Dena; Currie, Kris; Vich, Manuel Lagravere; Palomo, Juan Martin
2016-01-01
Objective To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority. PMID:27668196
Plain film measurement error in acute displaced midshaft clavicle fractures
Archer, Lori Anne; Hunt, Stephen; Squire, Daniel; Moores, Carl; Stone, Craig; O’Dea, Frank; Furey, Andrew
2016-01-01
Background Clavicle fractures are common and optimal treatment remains controversial. Recent literature suggests operative fixation of acute displaced mid-shaft clavicle fractures (DMCFs) shortened more than 2 cm improves outcomes. We aimed to identify correlation between plain film and computed tomography (CT) measurement of displacement and the inter- and intraobserver reliability of repeated radiographic measurements. Methods We obtained radiographs and CT scans of patients with acute DMCFs. Three orthopedic staff and 3 residents measured radiographic displacement at time zero and 2 weeks later. The CT measurements identified absolute shortening in 3 dimensions (by subtracting the length of the fractured from the intact clavicle). We then compared shortening measured on radiographs and shortening measured in 3 dimensions on CT. Interobserver and intraobserver reliability were calculated. Results We reviewed the fractures of 22 patients. Bland–Altman repeatability coefficient calculations indicated that radiograph and CT measurements of shortening could not be correlated owing to an unacceptable amount of measurement error (6 cm). Interobserver reliability for plain radiograph measurements was excellent (Cronbach α = 0.90). Likewise, intraobserver reliabilities for plain radiograph measurements as calculated with paired t tests indicated excellent correlation (p > 0.05 in all but 1 observer [p = 0.04]). Conclusion To establish shortening as an indication for DMCF fixation, reliable measurement tools are required. The low correlation between plain film and CT measurements we observed suggests further research is necessary to establish what imaging modality reliably predicts shortening. Our results indicate weak correlation between radiograph and CT measurement of acute DMCF shortening. PMID:27438054
Martin, RobRoy L.
2012-01-01
Purpose/Background: The purpose of this study was to systematically review the literature for functional performance tests with evidence of reliability and validity that could be used for a young, athletic population with hip dysfunction. Methods: A search of PubMed and SPORTDiscus databases were performed to identify movement, balance, hop/jump, or agility functional performance tests from the current peer-reviewed literature used to assess function of the hip in young, athletic subjects. Results: The single-leg stance, deep squat, single-leg squat, and star excursion balance tests (SEBT) demonstrated evidence of validity and normative data for score interpretation. The single-leg stance test and SEBT have evidence of validity with association to hip abductor function. The deep squat test demonstrated evidence as a functional performance test for evaluating femoroacetabular impingement. Hop/Jump tests and agility tests have no reported evidence of reliability or validity in a population of subjects with hip pathology. Conclusions: Use of functional performance tests in the assessment of hip dysfunction has not been well established in the current literature. Diminished squat depth and provocation of pain during the single-leg balance test have been associated with patients diagnosed with FAI and gluteal tendinopathy, respectively. The SEBT and single-leg squat tests provided evidence of convergent validity through an analysis of kinematics and muscle function in normal subjects. Reliability of functional performance tests have not been established on patients with hip dysfunction. Further study is needed to establish reliability and validity of functional performance tests that can be used in a young, athletic population with hip dysfunction. Level of Evidence: 2b (Systematic Review of Literature) PMID:22893860
Reliability Issues and Solutions in Flexible Electronics Under Mechanical Fatigue
NASA Astrophysics Data System (ADS)
Yi, Seol-Min; Choi, In-Suk; Kim, Byoung-Joon; Joo, Young-Chang
2018-07-01
Flexible devices are of significant interest due to their potential expansion of the application of smart devices into various fields, such as energy harvesting, biological applications and consumer electronics. Due to the mechanically dynamic operations of flexible electronics, their mechanical reliability must be thoroughly investigated to understand their failure mechanisms and lifetimes. Reliability issue caused by bending fatigue, one of the typical operational limitations of flexible electronics, has been studied using various test methodologies; however, electromechanical evaluations which are essential to assess the reliability of electronic devices for flexible applications had not been investigated because the testing method was not established. By employing the in situ bending fatigue test, we has studied the failure mechanism for various conditions and parameters, such as bending strain, fatigue area, film thickness, and lateral dimensions. Moreover, various methods for improving the bending reliability have been developed based on the failure mechanism. Nanostructures such as holes, pores, wires and composites of nanoparticles and nanotubes have been suggested for better reliability. Flexible devices were also investigated to find the potential failures initiated by complex structures under bending fatigue strain. In this review, the recent advances in test methodology, mechanism studies, and practical applications are introduced. Additionally, perspectives including the future advance to stretchable electronics are discussed based on the current achievements in research.
Reliability Issues and Solutions in Flexible Electronics Under Mechanical Fatigue
NASA Astrophysics Data System (ADS)
Yi, Seol-Min; Choi, In-Suk; Kim, Byoung-Joon; Joo, Young-Chang
2018-03-01
Flexible devices are of significant interest due to their potential expansion of the application of smart devices into various fields, such as energy harvesting, biological applications and consumer electronics. Due to the mechanically dynamic operations of flexible electronics, their mechanical reliability must be thoroughly investigated to understand their failure mechanisms and lifetimes. Reliability issue caused by bending fatigue, one of the typical operational limitations of flexible electronics, has been studied using various test methodologies; however, electromechanical evaluations which are essential to assess the reliability of electronic devices for flexible applications had not been investigated because the testing method was not established. By employing the in situ bending fatigue test, we has studied the failure mechanism for various conditions and parameters, such as bending strain, fatigue area, film thickness, and lateral dimensions. Moreover, various methods for improving the bending reliability have been developed based on the failure mechanism. Nanostructures such as holes, pores, wires and composites of nanoparticles and nanotubes have been suggested for better reliability. Flexible devices were also investigated to find the potential failures initiated by complex structures under bending fatigue strain. In this review, the recent advances in test methodology, mechanism studies, and practical applications are introduced. Additionally, perspectives including the future advance to stretchable electronics are discussed based on the current achievements in research.
Zhang, Jiawen; He, Shaohui; Wang, Dahai; Liu, Yangpeng; Yao, Wenbo; Liu, Xiabing
2018-01-01
Based on the operating Chegongzhuang heat-supplying tunnel in Beijing, the reliability of its lining structure under the action of large thrust and thermal effect is studied. According to the characteristics of a heat-supplying tunnel service, a three-dimensional numerical analysis model was established based on the mechanical tests on the in-situ specimens. The stress and strain of the tunnel structure were obtained before and after the operation. Compared with the field monitoring data, the rationality of the model was verified. After extracting the internal force of the lining structure, the improved method of subset simulation was proposed as the performance function to calculate the reliability of the main control section of the tunnel. In contrast to the traditional calculation method, the analytic relationship between the sample numbers in the subset simulation method and Monte Carlo method was given. The results indicate that the lining structure is greatly influenced by coupling in the range of six meters from the fixed brackets, especially the tunnel floor. The improved subset simulation method can greatly save computation time and improve computational efficiency under the premise of ensuring the accuracy of calculation. It is suitable for the reliability calculation of tunnel engineering, because “the lower the probability, the more efficient the calculation.” PMID:29401691
Consistency of Lower-Body Dimensions Using Surface Landmarks and Simple Measurement Tools.
Caia, Johnpaul; Weiss, Lawrence W; Chiu, Loren Z F; Schilling, Brian K; Paquette, Max R
2016-09-01
Caia, J, Weiss, LW, Chiu, LZF, Schilling, BK, and Paquette, MR. Consistency of lower-body dimensions using surface landmarks and simple measurement tools. J Strength Cond Res 30(9): 2600-2608, 2016-Body dimensions may influence various types of physical performance. This study was designed to establish the reliability and precision of bilateral lower-body dimensions using surface anatomic landmarks and either sliding calipers or goniometry. Fifty university students (25 men and 25 women) were measured on 2 separate occasions separated by 48 or 72 hours. A small digital caliper was used to acquire longitudinal dimensions of the feet, whereas a larger broad-blade caliper was used to measure lower-limb, hip, and pelvic dimensions. Quadriceps angle (Q-angle) was determined through surface goniometry. Data for all foot and lower-limb dimensions were both reliable and precise (intraclass correlation coefficient (ICC) ≥0.72, SEM 0.1-0.5 cm). Measures of Q-angle were also reliable and precise (ICC ≥0.85, SEM 0.2-0.4°). Findings from this investigation demonstrate that lower-body dimensions may be reliably and precisely measured through simple practical tests, when surface anatomic landmarks and standardized procedures are used. Although intertester reliability remains to be established, meticulous adherence to specific measurement protocols is likely to yield viable output for lower-body dimensions when more sophisticated methods are unavailable or inappropriate.
Beardsley, Chris; Egerton, Tim; Skinner, Brendon
2016-01-01
Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.
NASA Astrophysics Data System (ADS)
Feng, Zhixin
2018-02-01
Projector calibration is crucial for a camera-projector three-dimensional (3-D) structured light measurement system, which has one camera and one projector. In this paper, a novel projector calibration method is proposed based on digital image correlation. In the method, the projector is viewed as an inverse camera, and a plane calibration board with feature points is used to calibrate the projector. During the calibration processing, a random speckle pattern is projected onto the calibration board with different orientations to establish the correspondences between projector images and camera images. Thereby, dataset for projector calibration are generated. Then the projector can be calibrated using a well-established camera calibration algorithm. The experiment results confirm that the proposed method is accurate and reliable for projector calibration.
An Integrated Approach to Establish Validity and Reliability of Reading Tests
ERIC Educational Resources Information Center
Razi, Salim
2012-01-01
This study presents the processes of developing and establishing reliability and validity of a reading test by administering an integrative approach as conventional reliability and validity measures superficially reveals the difficulty of a reading test. In this respect, analysing vocabulary frequency of the test is regarded as a more eligible way…
New Trends in Two-Way Time and Frequency Transfer via Satellite
1999-12-01
Recent developments performed with SATRE two-way time transfer ( TWSTFT ) modems resulted in significant performance upgrades and operational...improvements of the TWSTFT method These are aimed to reduce : manpower effort and to provide reliable, real-time data via a centralized monitoring and...collection have been used throughout the experiment INTRODUCTION Two-Way Time and Frequency Transfer via Satellite ( TWSTFT ) is a well established method to
Transformation From a Conventional Clinical Microbiology Laboratory to Full Automation.
Moreno-Camacho, José L; Calva-Espinosa, Diana Y; Leal-Leyva, Yoseli Y; Elizalde-Olivas, Dolores C; Campos-Romero, Abraham; Alcántar-Fernández, Jonathan
2017-12-22
To validate the performance, reproducibility, and reliability of BD automated instruments in order to establish a fully automated clinical microbiology laboratory. We used control strains and clinical samples to assess the accuracy, reproducibility, and reliability of the BD Kiestra WCA, the BD Phoenix, and BD Bruker MALDI-Biotyper instruments and compared them to previously established conventional methods. The following processes were evaluated: sample inoculation and spreading, colony counts, sorting of cultures, antibiotic susceptibility test, and microbial identification. The BD Kiestra recovered single colonies in less time than conventional methods (e.g. E. coli, 7h vs 10h, respectively) and agreement between both methodologies was excellent for colony counts (κ=0.824) and sorting cultures (κ=0.821). Antibiotic susceptibility tests performed with BD Phoenix and disk diffusion demonstrated 96.3% agreement with both methods. Finally, we compared microbial identification in BD Phoenix and Bruker MALDI-Biotyper and observed perfect agreement (κ=1) and identification at a species level for control strains. Together these instruments allow us to process clinical urine samples in 36h (effective time). The BD automated technologies have improved performance compared with conventional methods, and are suitable for its implementation in very busy microbiology laboratories. © American Society for Clinical Pathology 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Genetic engineering of Ganoderma lucidum for the efficient production of ganoderic acids.
Xu, Jun-Wei; Zhong, Jian-Jiang
2015-01-01
Ganoderma lucidum is a well-known traditional medicinal mushroom that produces ganoderic acids with numerous interesting bioactivities. Genetic engineering is an efficient approach to improve ganoderic acid biosynthesis. However, reliable genetic transformation methods and appropriate genetic manipulation strategies remain underdeveloped and thus should be enhanced. We previously established a homologous genetic transformation method for G. lucidum; we also applied the established method to perform the deregulated overexpression of a homologous 3-hydroxy-3-methyl-glutaryl coenzyme A reductase gene in G. lucidum. Engineered strains accumulated more ganoderic acids than wild-type strains. In this report, the genetic transformation systems of G. lucidum are described; current trends are also presented to improve ganoderic acid production through the genetic manipulation of G. lucidum.
Modification site localization scoring integrated into a search engine.
Baker, Peter R; Trinidad, Jonathan C; Chalkley, Robert J
2011-07-01
Large proteomic data sets identifying hundreds or thousands of modified peptides are becoming increasingly common in the literature. Several methods for assessing the reliability of peptide identifications both at the individual peptide or data set level have become established. However, tools for measuring the confidence of modification site assignments are sparse and are not often employed. A few tools for estimating phosphorylation site assignment reliabilities have been developed, but these are not integral to a search engine, so require a particular search engine output for a second step of processing. They may also require use of a particular fragmentation method and are mostly only applicable for phosphorylation analysis, rather than post-translational modifications analysis in general. In this study, we present the performance of site assignment scoring that is directly integrated into the search engine Protein Prospector, which allows site assignment reliability to be automatically reported for all modifications present in an identified peptide. It clearly indicates when a site assignment is ambiguous (and if so, between which residues), and reports an assignment score that can be translated into a reliability measure for individual site assignments.
A novel HPLC fluorescence method for the quantification of methylphenidate in human plasma
Zhu, Hao-Jie; Wang, Jun-Sheng; Patrick, Kennerly S.; Donovan, Jennifer L.; DeVane, C. Lindsay; Markowitz, John S.
2007-01-01
A number of analytical methods have been established to quantify methylphenidate (MPH). However, to date no HPLC methods are applicable to human pharmacokinetic studies without the use of mass spectrometry (MS) detection. We developed a sensitive and reliable HPLC-fluorescence method for the determination of MPH in human plasma using 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride (DIB-Cl) as the derivatizing agent. An established GC-MS method was adopted in this study as a comparator assay. MPH was derivatized DIB-Cl, and separated isocratically on a C18 column using a HPLC system with fluorescence detection (λex: 330 nm, λem: 460 nm). The lower limit of determination was found to be 1 ng/mL. A linear calibration curve was obtained over the concentrations ranging from 1 to 80 ng/mL (r=0.998). The relative standard deviations of intra-day and inter-day variations were ≤ 9.10 % and ≤ 7.58 %, respectively. The accuracy ranged between 92.59 % and 103.06 %. The method was successfully applied to the pharmacokinetic study of a subject who received a single oral dose (0.3 mg/kg) of immediate-release MPH and yielded consistent results with that of the GC-MS method. This method is the first HPLC assay with non-MS detection providing sufficient reliability and sensitivity for both pre-clinical and clinical studies of MPH. PMID:17804308
Reliable probabilities through statistical post-processing of ensemble predictions
NASA Astrophysics Data System (ADS)
Van Schaeybroeck, Bert; Vannitsem, Stéphane
2013-04-01
We develop post-processing or calibration approaches based on linear regression that make ensemble forecasts more reliable. We enforce climatological reliability in the sense that the total variability of the prediction is equal to the variability of the observations. Second, we impose ensemble reliability such that the spread around the ensemble mean of the observation coincides with the one of the ensemble members. In general the attractors of the model and reality are inhomogeneous. Therefore ensemble spread displays a variability not taken into account in standard post-processing methods. We overcome this by weighting the ensemble by a variable error. The approaches are tested in the context of the Lorenz 96 model (Lorenz 1996). The forecasts become more reliable at short lead times as reflected by a flatter rank histogram. Our best method turns out to be superior to well-established methods like EVMOS (Van Schaeybroeck and Vannitsem, 2011) and Nonhomogeneous Gaussian Regression (Gneiting et al., 2005). References [1] Gneiting, T., Raftery, A. E., Westveld, A., Goldman, T., 2005: Calibrated probabilistic forecasting using ensemble model output statistics and minimum CRPS estimation. Mon. Weather Rev. 133, 1098-1118. [2] Lorenz, E. N., 1996: Predictability - a problem partly solved. Proceedings, Seminar on Predictability ECMWF. 1, 1-18. [3] Van Schaeybroeck, B., and S. Vannitsem, 2011: Post-processing through linear regression, Nonlin. Processes Geophys., 18, 147.
Hattotuwagama, Channa K; Guan, Pingping; Doytchinova, Irini A; Flower, Darren R
2004-11-21
Quantitative structure-activity relationship (QSAR) analysis is a main cornerstone of modern informatic disciplines. Predictive computational models, based on QSAR technology, of peptide-major histocompatibility complex (MHC) binding affinity have now become a vital component of modern day computational immunovaccinology. Historically, such approaches have been built around semi-qualitative, classification methods, but these are now giving way to quantitative regression methods. The additive method, an established immunoinformatics technique for the quantitative prediction of peptide-protein affinity, was used here to identify the sequence dependence of peptide binding specificity for three mouse class I MHC alleles: H2-D(b), H2-K(b) and H2-K(k). As we show, in terms of reliability the resulting models represent a significant advance on existing methods. They can be used for the accurate prediction of T-cell epitopes and are freely available online ( http://www.jenner.ac.uk/MHCPred).
Development of a hybrid pollution index for heavy metals in marine and estuarine sediments.
Brady, James P; Ayoko, Godwin A; Martens, Wayde N; Goonetilleke, Ashantha
2015-05-01
Heavy metal pollution of sediments is a growing concern in most parts of the world, and numerous studies focussed on identifying contaminated sediments by using a range of digestion methods and pollution indices to estimate sediment contamination have been described in the literature. The current work provides a critical review of the more commonly used sediment digestion methods and identifies that weak acid digestion is more likely to provide guidance on elements that are likely to be bioavailable than other traditional methods of digestion. This work also reviews common pollution indices and identifies the Nemerow Pollution Index as the most appropriate method for establishing overall sediment quality. Consequently, a modified Pollution Index that can lead to a more reliable understanding of whole sediment quality is proposed. This modified pollution index is then tested against a number of existing studies and demonstrated to give a reliable and rapid estimate of sediment contamination and quality.
Bai, Xiao-ping; Zhang, Xi-wei
2013-01-01
Selecting construction schemes of the building engineering project is a complex multiobjective optimization decision process, in which many indexes need to be selected to find the optimum scheme. Aiming at this problem, this paper selects cost, progress, quality, and safety as the four first-order evaluation indexes, uses the quantitative method for the cost index, uses integrated qualitative and quantitative methodologies for progress, quality, and safety indexes, and integrates engineering economics, reliability theories, and information entropy theory to present a new evaluation method for building construction project. Combined with a practical case, this paper also presents detailed computing processes and steps, including selecting all order indexes, establishing the index matrix, computing score values of all order indexes, computing the synthesis score, sorting all selected schemes, and making analysis and decision. Presented method can offer valuable references for risk computing of building construction projects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, Dave; Brunett, Acacia J.; Bucknor, Matthew
GE Hitachi Nuclear Energy (GEH) and Argonne National Laboratory are currently engaged in a joint effort to modernize and develop probabilistic risk assessment (PRA) techniques for advanced non-light water reactors. At a high level the primary outcome of this project will be the development of next-generation PRA methodologies that will enable risk-informed prioritization of safety- and reliability-focused research and development, while also identifying gaps that may be resolved through additional research. A subset of this effort is the development of a reliability database (RDB) methodology to determine applicable reliability data for inclusion in the quantification of the PRA. The RDBmore » method developed during this project seeks to satisfy the requirements of the Data Analysis element of the ASME/ANS Non-LWR PRA standard. The RDB methodology utilizes a relevancy test to examine reliability data and determine whether it is appropriate to include as part of the reliability database for the PRA. The relevancy test compares three component properties to establish the level of similarity to components examined as part of the PRA. These properties include the component function, the component failure modes, and the environment/boundary conditions of the component. The relevancy test is used to gauge the quality of data found in a variety of sources, such as advanced reactor-specific databases, non-advanced reactor nuclear databases, and non-nuclear databases. The RDB also establishes the integration of expert judgment or separate reliability analysis with past reliability data. This paper provides details on the RDB methodology, and includes an example application of the RDB methodology for determining the reliability of the intermediate heat exchanger of a sodium fast reactor. The example explores a variety of reliability data sources, and assesses their applicability for the PRA of interest through the use of the relevancy test.« less
Assessing Lower Limb Alignment: Comparison of Standard Knee Xray vs Long Leg View.
Zampogna, Biagio; Vasta, Sebastiano; Amendola, Annunziato; Uribe-Echevarria Marbach, Bastian; Gao, Yubo; Papalia, Rocco; Denaro, Vincenzo
2015-01-01
High tibial osteotomy (HTO) is a well-established and commonly utilized technique in medial knee osteoarthritis secondary to varus malalignment. Accurate measurement of the preoperative limb alignment, and the amount of correction required are essential when planning limb realignment surgery. The hip-knee-ankle angle (HKA) measured on a full length weightbearing (FLWB) X-ray in the standing position is considered the gold standard, since it allows for reliable and accurate measurement of the mechanical axis of the whole lower extremity. In general practice, alignment is often evaluated on standard anteroposterior weightbearing (APWB) X-rays, as the angle between the femur and tibial anatomic axis (TFa). It is, therefore, of value to establish if measuring the anatomical axis from limited APWB is an effective measure of knee alignment especially in patients undergoing osteotomy about the knee. Three independent observers measured preoperative and postoperative FTa with standard method (FTa1) and with circles method (FTa2) on APWB X-ray and the HKA on FLWB X-ray at three different time-points separated by a two-week period. Intra-observer and inter-observer reliabilities and the comparison and relationship between anatomical and mechanical alignment were calculated. Intra- and interclass coefficients for all the three methods indicated excellent reliability, having all the values above 0.80. Using the mean of paired t-student test, the comparison of HKA versus TFa1 and TFa2 showed a statistically significant difference (p<.0001) both for the pre-operative and post-operative sets of values. The correlation between the HKA and FTal was found poor for the preoperative set (R=0.26) and fair for the postoperative one (R=0.53), while the new circles method showed a higher correlation in both the preoperative (R=0.71) and postoperative sets (R=0.79). Intra-observer reliability was high for HKA, FTal and FTa2 on APWB x-rays in the pre- and post-operative setting. Inter-rater reliability was higher for HKA and TFa2 compared to FTal. The femoro-tibial angle as measured on APWB with the traditional method (FTal) has a weak correlation with the HKA, and based on these findings, should not be used in everyday practice. The FTa2 showed better correlation with the HKA, although not excellent. Level III, Retrospective study.
Economical drive for large tube mills by means of planetary gears
NASA Technical Reports Server (NTRS)
Ackle, W.
1980-01-01
The performance of heavy-duty planetary gear drives for ball mills used in the cement industry since 1967 is described. These gear drives transmit up to 8500 HP per installation. A reliable method for establishing gear drive efficiency is described and possible savings due to higher efficiency are indicated.
Pressurized Wideband Absorbance Findings in Healthy Neonates: A Preliminary Study
ERIC Educational Resources Information Center
Wali, Hamzah A.; Mazlan, Rafidah; Kei, Joseph
2017-01-01
Purpose: The present study aimed to establish normative data for wideband absorbance (WBA) measured at tympanometric peak pressure (TPP) and 0 daPa and to assess the test-retest reliability of both measurements in healthy neonates. Method: Participants of this cross-sectional study included 99 full-term neonates (165 ears) with mean chronological…
USDA-ARS?s Scientific Manuscript database
Immunoassay for low molecular weight food contaminants, such as pesticides, veterinary drugs, and mycotoxins is now a well-established technique which meets the demands for a rapid, reliable, and cost-effective analytical method. However, due to limited understanding of the fundamental aspects of i...
Application of reliability-centered-maintenance to BWR ECCS motor operator valve performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feltus, M.A.; Choi, Y.A.
1993-01-01
This paper describes the application of reliability-centered maintenance (RCM) methods to plant probabilistic risk assessment (PRA) and safety analyses for four boiling water reactor emergency core cooling systems (ECCSs): (1) high-pressure coolant injection (HPCI); (2) reactor core isolation cooling (RCIC); (3) residual heat removal (RHR); and (4) core spray systems. Reliability-centered maintenance is a system function-based technique for improving a preventive maintenance program that is applied on a component basis. Those components that truly affect plant function are identified, and maintenance tasks are focused on preventing their failures. The RCM evaluation establishes the relevant criteria that preserve system function somore » that an RCM-focused approach can be flexible and dynamic.« less
NASA Astrophysics Data System (ADS)
Heller, R. A.; Thangjitham, S.; Wang, X.
1992-04-01
The state of stress in a cylindrical structure consisting of multiple layers of carbon-carbon composite and subjected to thermal and pressure shock are analyzed using an elasticity approach. The reliability of the structure based on the weakest link concept and the Weibull distribution is also calculated. Coupled thermo-elasticity is first assumed and is shown to be unnecessary for the material considered. The effects of external and internal thermal shock as well as a superimposed pressure shock are examined. It is shown that for the geometry chosen, the structure may fail when exposed to thermal shock alone while a superimposed pressure shock can mitigate the probability of failure.
Rao, Xueqin; Sun, Jie
2015-09-01
Watermelon silver mottle virus (WSMoV), which belongs to the genus Tospovirus , causes significant loss in Cucurbitaceae plants. Development of a highly sensitive and reliable detection method for WSMoV. Recombinant plasmids for targeting the sequence of nucleocapsid protein gene of WSMoV were constructed. SYBR Green I real-time PCR was established and evaluated with standard recombinant plasmids and 27 watermelon samples showing WSMoV infection symptoms. The recombinant plasmid was used as template for SYBR Green I real-time PCR to generate standard and melting curves. Melting curve analysis indicated no primer-dimers and non-specific products in the assay. No cross-reaction was observed with Capsicum chlorosis virus (genus Tospovirus ) and Cucumber mosaic virus (genus Cucumovirus). Repeatability tests indicated that inter-assay variability of the Ct values was 1.6%. A highly sensitive, reliable and rapid detection method of SYBR Green I real-time PCR for timely detection of WSMoV plants and vector thrips was established, which will facilitate disease forecast and control.
Inspection of Piezoceramic Transducers Used for Structural Health Monitoring
Mueller, Inka; Fritzen, Claus-Peter
2017-01-01
The use of piezoelectric wafer active sensors (PWAS) for structural health monitoring (SHM) purposes is state of the art for acousto-ultrasonic-based methods. For system reliability, detailed information about the PWAS itself is necessary. This paper gives an overview on frequent PWAS faults and presents the effects of these faults on the wave propagation, used for active acousto-ultrasonics-based SHM. The analysis of the wave field is based on velocity measurements using a laser Doppler vibrometer (LDV). New and established methods of PWAS inspection are explained in detail, listing advantages and disadvantages. The electro-mechanical impedance spectrum as basis for these methods is discussed for different sensor faults. This way this contribution focuses on a detailed analysis of PWAS and the need of their inspection for an increased reliability of SHM systems. PMID:28772431
Tau Oligomers as Pathogenic Seeds: Preparation and Propagation In Vitro and In Vivo.
Gerson, Julia E; Sengupta, Urmi; Kayed, Rakez
2017-01-01
Tau oligomers have been shown to be the main toxic tau species in a number of neurodegenerative disorders. In order to study tau oligomers both in vitro and in vivo, we have established methods for the reliable preparation, isolation, and detection of tau oligomers. Methods for the seeding of tau oligomers, isolation of tau oligomers from tissue, and detection of tau oligomers using tau oligomer-specific antibodies by biochemical and immunohistochemical methods are detailed below.
Aguilar, Hector N; Battié, Michele C
2017-01-01
Osteoarthritis is a common hip joint disease, involving loss of articular cartilage. The prevalence and prognosis of hip osteoarthritis have been difficult to determine, with various clinical and radiological methods used to derive epidemiological estimates exhibiting significant heterogeneity. MRI-based methods directly visualise hip joint cartilage, and offer potential to more reliably define presence and severity of osteoarthritis, but have been underused. We performed a systematic review of MRI-based estimates of hip articular cartilage in the general population and in patients with established osteoarthritis, using MEDLINE, EMBASE and SCOPUS current to June 2016, with search terms such as ‘hip’, ‘femoral head’, ‘cartilage’, ‘volume’, ‘thickness’, ‘MRI’, etc. Ultimately, 11 studies were found appropriate for inclusion, but they were heterogeneous in osteoarthritis assessment methodology and composition. Overall, the studies consistently demonstrate the reliability and potential clinical utility of MRI-based estimates. However, no longitudinal data or reference values for hip cartilage thickness or volume have been published, limiting the ability of MRI to define or risk-stratify hip osteoarthritis. MRI-based techniques are available to quantify articular cartilage signal, volume, thickness and defects, which could establish the sequence and rate of articular cartilage changes at the hip that yield symptomatic osteoarthritis. However, prevalence and rates of progression of hip osteoarthritis have not been established in any MRI studies in the general population. Future investigations could fill this important knowledge gap using robust MRI methods in population-based cross-sectional and longitudinal studies. PMID:28405471
Dai, Sheng-Yun; Xu, Bing; Zhang, Yi; Li, Jian-Yu; Sun, Fei; Shi, Xin-Yuan; Qiao, Yan-Jiang
2016-09-01
Coptis chinensis (Huanglian) is a commonly used traditional Chinese medicine (TCM) herb and alkaloids are the most important chemical constituents in it. In the present study, an isocratic reverse phase high performance liquid chromatography (RP-HPLC) method allowing the separation of six alkaloids in Huanglian was for the first time developed under the quality by design (QbD) principles. First, five chromatographic parameters were identified to construct a Plackett-Burman experimental design. The critical resolution, analysis time, and peak width were responses modeled by multivariate linear regression. The results showed that the percentage of acetonitrile, concentration of sodium dodecyl sulfate, and concentration of potassium phosphate monobasic were statistically significant parameters (P < 0.05). Then, the Box-Behnken experimental design was applied to further evaluate the interactions between the three parameters on selected responses. Full quadratic models were built and used to establish the analytical design space. Moreover, the reliability of design space was estimated by the Bayesian posterior predictive distribution. The optimal separation was predicted at 40% acetonitrile, 1.7 g·mL(-1) of sodium dodecyl sulfate and 0.03 mol·mL(-1) of potassium phosphate monobasic. Finally, the accuracy profile methodology was used to validate the established HPLC method. The results demonstrated that the QbD concept could be efficiently used to develop a robust RP-HPLC analytical method for Huanglian. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kanjilal, Oindrila; Manohar, C. S.
2017-07-01
The study considers the problem of simulation based time variant reliability analysis of nonlinear randomly excited dynamical systems. Attention is focused on importance sampling strategies based on the application of Girsanov's transformation method. Controls which minimize the distance function, as in the first order reliability method (FORM), are shown to minimize a bound on the sampling variance of the estimator for the probability of failure. Two schemes based on the application of calculus of variations for selecting control signals are proposed: the first obtains the control force as the solution of a two-point nonlinear boundary value problem, and, the second explores the application of the Volterra series in characterizing the controls. The relative merits of these schemes, vis-à-vis the method based on ideas from the FORM, are discussed. Illustrative examples, involving archetypal single degree of freedom (dof) nonlinear oscillators, and a multi-degree of freedom nonlinear dynamical system, are presented. The credentials of the proposed procedures are established by comparing the solutions with pertinent results from direct Monte Carlo simulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, Tsong-Lun; Varuttamaseni, Athi; Baek, Joo-Seok
The U.S. Nuclear Regulatory Commission (NRC) encourages the use of probabilistic risk assessment (PRA) technology in all regulatory matters, to the extent supported by the state-of-the-art in PRA methods and data. Although much has been accomplished in the area of risk-informed regulation, risk assessment for digital systems has not been fully developed. The NRC established a plan for research on digital systems to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems in the PRAs of nuclear power plants (NPPs), and (2) incorporating digital systems in the NRC's risk-informed licensing and oversight activities.more » Under NRC's sponsorship, Brookhaven National Laboratory (BNL) explored approaches for addressing the failures of digital instrumentation and control (I and C) systems in the current NPP PRA framework. Specific areas investigated included PRA modeling digital hardware, development of a philosophical basis for defining software failure, and identification of desirable attributes of quantitative software reliability methods. Based on the earlier research, statistical testing is considered a promising method for quantifying software reliability. This paper describes a statistical software testing approach for quantifying software reliability and applies it to the loop-operating control system (LOCS) of an experimental loop of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL).« less
Precise Relative Earthquake Magnitudes from Cross Correlation
Cleveland, K. Michael; Ammon, Charles J.
2015-04-21
We present a method to estimate precise relative magnitudes using cross correlation of seismic waveforms. Our method incorporates the intercorrelation of all events in a group of earthquakes, as opposed to individual event pairings relative to a reference event. This method works well when a reliable reference event does not exist. We illustrate the method using vertical strike-slip earthquakes located in the northeast Pacific and Panama fracture zone regions. Our results are generally consistent with the Global Centroid Moment Tensor catalog, which we use to establish a baseline for the relative event sizes.
A method to establish stimulus control and compliance with instructions.
Borgen, John G; Charles Mace, F; Cavanaugh, Brenna M; Shamlian, Kenneth; Lit, Keith R; Wilson, Jillian B; Trauschke, Stephanie L
2017-10-01
We evaluated a unique procedure to establish compliance with instructions in four young children diagnosed with autism spectrum disorder (ASD) who had low levels of compliance. Our procedure included methods to establish a novel therapist as a source of positive reinforcement, reliably evoke orienting responses to the therapist, increase the number of exposures to instruction-compliance-reinforcer contingencies, and minimize the number of exposures to instruction-noncompliance-no reinforcer contingencies. We further alternated between instructions with a high probability of compliance (high-p instructions) with instructions that had a prior low probability of compliance (low-p instructions) as soon as low-p instructions lost stimulus control. The intervention is discussed in relation to the conditions necessary for the development of stimulus control and as an example of a variation of translational research. © 2017 Society for the Experimental Analysis of Behavior.
Experience with modified aerospace reliability and quality assurance method for wind turbines
NASA Technical Reports Server (NTRS)
Klein, W. E.
1982-01-01
The SR&QA approach assures that the machine is not hazardous to the public or operating personnel, can operate unattended on a utility grid, demonstrates reliability operation, and helps establish the quality assurance and maintainability requirements for future wind turbine projects. The approach consisted of modified failure modes and effects analysis (FMEA) during the design phase, minimal hardware inspection during parts fabrication, and three simple documents to control activities during machine construction and operation. Five years experience shows that this low cost approach works well enough that it should be considered by others for similar projects.
Reliability of real-time ultrasound for the assessment of transversus abdominis function.
Kidd, Adrian W; Magee, Scott; Richardson, Carolyn A
2002-07-01
Transversus abdominis (TrA) has now been established as a key muscle for the stabilization of the lumbar spine and sacroiliac joints. Significantly, dysfunction of this muscle has also been implicated in low back pain. Real-time ultrasound (US) is a non-invasive procedure that has the potential to evaluate objectively the function of TrA. To investigate M-mode US as a reliable method of assessing TrA function. M-mode US was used to measure the width of TrA as subjects drew in their lower abdominal wall at a controlled speed to a target depth. Eleven subjects were imaged. the measures of TrA width were reliable and ranged between 3.14mm relaxed and 6.35mm contracted. The standard error of measurement ranged between 0.18mm and 0.57mm. M-mode US provides a reliable non-invasive measure of a controlled contraction of TrA.
The Validation of a Case-Based, Cumulative Assessment and Progressions Examination
Coker, Adeola O.; Copeland, Jeffrey T.; Gottlieb, Helmut B.; Horlen, Cheryl; Smith, Helen E.; Urteaga, Elizabeth M.; Ramsinghani, Sushma; Zertuche, Alejandra; Maize, David
2016-01-01
Objective. To assess content and criterion validity, as well as reliability of an internally developed, case-based, cumulative, high-stakes third-year Annual Student Assessment and Progression Examination (P3 ASAP Exam). Methods. Content validity was assessed through the writing-reviewing process. Criterion validity was assessed by comparing student scores on the P3 ASAP Exam with the nationally validated Pharmacy Curriculum Outcomes Assessment (PCOA). Reliability was assessed with psychometric analysis comparing student performance over four years. Results. The P3 ASAP Exam showed content validity through representation of didactic courses and professional outcomes. Similar scores on the P3 ASAP Exam and PCOA with Pearson correlation coefficient established criterion validity. Consistent student performance using Kuder-Richardson coefficient (KR-20) since 2012 reflected reliability of the examination. Conclusion. Pharmacy schools can implement internally developed, high-stakes, cumulative progression examinations that are valid and reliable using a robust writing-reviewing process and psychometric analyses. PMID:26941435
Failure analysis of solid rocket apogee motors
NASA Technical Reports Server (NTRS)
Martin, P. J.
1972-01-01
The analysis followed five selected motors through initial design, development, test, qualification, manufacture, and final flight reports. An audit was conducted at the manufacturing plants to complement the literature search with firsthand observations of the current philosophies and practices that affect reliability of the motors. A second literature search emphasized acquisition of spacecraft and satellite data bearing on solid motor reliability. It was concluded that present practices at the plants yield highly reliable flight hardware. Reliability can be further improved by new developments of aft-end bonding and initiator/igniter nondestructive test methods, a safe/arm device, and an insulation formulation. Minimum diagnostic instrumentation is recommended for all motor flights. Surplus motors should be used in margin testing. Criteria should be established for pressure and zone curing. The motor contractor should be represented at launch. New design analyses should be made of stretched motors and spacecraft/motor pairs.
NASA Technical Reports Server (NTRS)
Tamayo, Tak Chai
1987-01-01
Quality of software not only is vital to the successful operation of the space station, it is also an important factor in establishing testing requirements, time needed for software verification and integration as well as launching schedules for the space station. Defense of management decisions can be greatly strengthened by combining engineering judgments with statistical analysis. Unlike hardware, software has the characteristics of no wearout and costly redundancies, thus making traditional statistical analysis not suitable in evaluating reliability of software. A statistical model was developed to provide a representation of the number as well as types of failures occur during software testing and verification. From this model, quantitative measure of software reliability based on failure history during testing are derived. Criteria to terminate testing based on reliability objectives and methods to estimate the expected number of fixings required are also presented.
Espinoza-Venegas, Maritza; Sanhueza-Alvarado, Olivia; Ramírez-Elizondo, Noé; Sáez-Carrillo, Katia
2015-01-01
OBJECTIVE: The current study aimed to validate the construct and reliability of an emotional intelligence scale. METHOD: The Trait Meta-Mood Scale-24 was applied to 349 nursing students. The process included content validation, which involved expert reviews, pilot testing, measurements of reliability using Cronbach's alpha, and factor analysis to corroborate the validity of the theoretical model's construct. RESULTS: Adequate Cronbach coefficients were obtained for all three dimensions, and factor analysis confirmed the scale's dimensions (perception, comprehension, and regulation). CONCLUSION: The Trait Meta-Mood Scale is a reliable and valid tool to measure the emotional intelligence of nursing students. Its use allows for accurate determinations of individuals' abilities to interpret and manage emotions. At the same time, this new construct is of potential importance for measurements in nursing leadership; educational, organizational, and personal improvements; and the establishment of effective relationships with patients. PMID:25806642
Kneebone, Ian I.; Dewar, Sophie J.
2016-01-01
Background: The current study aimed to examine the psychometric properties of an attributional style measure that can be administered remotely, to people who have multiple sclerosis (MS). Methods: A total of 495 participants with MS were recruited. Participants completed the Attributional Style Questionnaire-Survey (ASQ-S) and two comparison measures of cognitive variables via postal survey on three occasions, each 12 months apart. Internal reliability, test-retest reliability and congruent validity were considered. Results: The internal reliability of the ASQ-S was good (α > 0.7). The test-retest correlations were significant, but failed to reach the 0.7 set. The congruent validity of the ASQ-S was established relative to the comparisons. Conclusions: The psychometric properties of the ASQ-S indicate that it shows promise as a tool for researchers investigating depression in people with MS and is likely sound to use clinically in this population. PMID:28450893
Liang, Qionglin; Qu, Jun; Luo, Guoan; Wang, Yiming
2006-02-13
In recent years, dietary supplements and herbal medicines are increasing in popularity all over the world. However, it is problematic that some manufacturers illegally included synthetic drugs in their products. Due to the extremely complex matrices of those products, most existing methods for screening illegal adulterations are time-consuming and liable to false positive. In this paper, a robust LC/MS/MS method for the high-throughput, sensitive and reliable determination of illegal adulterations from herbal medicines and dietary supplements was established. Minimal LC separation was employed and MRM was used to simultaneously monitor the three transitions under their respective optimal collision energy for each compound. Positive results were determined only if well-defined peaks appeared at all of the three transitions and the ratios among the peak areas were within given threshold. In this study, the method had been applied for the screening of nine most commonly adulterated therapeutic substances, such as sildenafil (Viagra) and famotidine, and the lower limits of detection of these compounds ranged from 0.05 to 1.5 ng/ml. Little sample preparation was needed for this method and the analysis time was less than 5 min/sample. The reliability has been demonstrated by the test with blank matrix. Over 200 products that were under suspicion by SDA of China had been assayed and till now no false negative or positive result was found. This method is rapid, simple, reliable and capable of screening multiple adulterants in one run.
Al-Abassi, Abdulla Ahmed; Al Saadi, Azan Saleh; Ahmed, Faisal
2018-06-19
Intra-abdominal pressure (IAP) can be measured by several indirect methods; however, the urinary bladder is largely preferred. The aim of this study was to compare intra-bladder pressure (IBP) at different levels of IAPs and assess its reliability as an indirect method for IAP measurement. We compared IBP with IAP in twenty-one patients undergoing laparoscopic cholecystectomy under general anesthesia. Measurements were recorded at increasing levels of insufflation pressures to approximately 22 mmHg. Pearson's correlation coefficient was calculated to establish the relationship between the two pressure measurements and Bland-Altman analysis was used to assess the limits of agreement between the two methods of measurements. The urinary bladder pressures reflected well the pressures in the abdominal cavity. Pearson correlation coefficient showed a good correlation between the two measurement techniques (r = 0.966, p < 0.0001) and Bland-Altman analysis indicated that the 95% limits of agreement between the two methods ranged from - 2.83 to 2.64. This range is accepted both clinically and according to the recommendations of the World Society of Abdominal Compartment Syndrome (WSACS). Our study showed that IBP measurement is a simple, minimally invasive method that may reliably estimates IAP in patients placed in supine position. Measurements for pressures higher than 12 mmHg may be less reliable. When applied clinically, this should alert the clinician to take safety measures to avoid abdominal compartment syndrome (ACS).
Schiffman, Eric L.; Truelove, Edmond L.; Ohrbach, Richard; Anderson, Gary C.; John, Mike T.; List, Thomas; Look, John O.
2011-01-01
AIMS The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. An overview is presented, including Axis I and II methodology and descriptive statistics for the study participant sample. This paper details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. Validity testing for the Axis II biobehavioral instruments was based on previously validated reference standards. METHODS The Axis I reference standards were based on the consensus of 2 criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion exam reliability was also assessed within study sites. RESULTS Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas ≥ 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion exam agreement with reference standards was excellent (k ≥ 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). CONCLUSION The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods. PMID:20213028
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ronold, K.O.; Nielsen, N.J.R.; Tura, F.
This paper demonstrates how a structural reliability method can be applied as a rational means to analyze free spans of submarine pipelines with respect to failure in ultimate loading, and to establish partial safety factors for design of such free spans against this failure mode. It is important to note that the described procedure shall be considered as an illustration of a structural reliability methodology, and that the results do not represent a set of final design recommendations. A scope of design cases, consisting of a number of available site-specific pipeline spans, is established and is assumed representative for themore » future occurrence of submarine pipeline spans. Probabilistic models for the wave and current loading and its transfer to stresses in the pipe wall of a pipeline span is established together with a stochastic representation of the material resistance. The event of failure in ultimate loading is considered as based on a limit state which is reached when the maximum stress over the design life of the pipeline exceeds the yield strength of the pipe material. The yielding limit state is considered an ultimate limit state (ULS).« less
Genetic engineering of Ganoderma lucidum for the efficient production of ganoderic acids
Xu, Jun-Wei; Zhong, Jian-Jiang
2015-01-01
Ganoderma lucidum is a well-known traditional medicinal mushroom that produces ganoderic acids with numerous interesting bioactivities. Genetic engineering is an efficient approach to improve ganoderic acid biosynthesis. However, reliable genetic transformation methods and appropriate genetic manipulation strategies remain underdeveloped and thus should be enhanced. We previously established a homologous genetic transformation method for G. lucidum; we also applied the established method to perform the deregulated overexpression of a homologous 3-hydroxy-3-methyl-glutaryl coenzyme A reductase gene in G. lucidum. Engineered strains accumulated more ganoderic acids than wild-type strains. In this report, the genetic transformation systems of G. lucidum are described; current trends are also presented to improve ganoderic acid production through the genetic manipulation of G. lucidum. PMID:26588475
Invasive species detection in Hawaiian rainforests using airborne imaging spectroscopy and LiDAR
Gregory P. Asner; David E. Knapp; Ty Kennedy-Bodoin; Matthew O. Jones; Roberta E. Martin; Joseph Boardman; Flint Hughes
2008-01-01
Remote sensing of invasive species is a critical component of conservation and management efforts, but reliable methods for the detection of invaders have not been widely established. In Hawaiian forests, we recently found that invasive trees often have hyperspectral signatures unique from that of native trees, but mapping based on spectral reflectance properties alone...
ERIC Educational Resources Information Center
Dorst, J.; Haag, A.; Knake, S.; Oertel, W. H.; Hamer, H. M.; Rosenow, F.
2008-01-01
Rationale: Functional transcranial Doppler sonography (fTCD) during word generation is well established for language lateralization. In this study, we evaluated a fTCD paradigm to reliably identify the non-dominant hemisphere. Methods: Twenty-nine right-handed healthy subjects (27.1 [plus or minus] 7.6 years) performed the "cube perspective test"…
Silviculture for multiple objectives in the Douglas-fir region.
R.O. Curtis; D.S. DeBell; C.A. Harrington; D.P. Lavender; J.B. St. Clair; J.C. Tappeiner; J.D. Walstad
1998-01-01
Silvicultural knowledge and practice have been evolving in the Pacific Northwest for nearly a century. Most research and management activities to date have focused on two major topics: (1) methods to regenerate older, naturally established forests after fire or timber harvest; and (2) growth and management of young stands. Today forest managers can reliably regenerate...
1990-02-01
CAlA WACe Mns. b. Amalgamated for all tank runs: (1) Significant wave height and mdal period of achieved wave condition. (2) Mean And .S mortions...experimental conditions. It is impossible to set sa jndtrd run lengths for all experimental conditions and so a method should be developed to analyse the
Constructing a Grounded Theory of E-Learning Assessment
ERIC Educational Resources Information Center
Alonso-Díaz, Laura; Yuste-Tosina, Rocío
2015-01-01
This study traces the development of a grounded theory of assessment in e-learning environments, a field in need of research to establish the parameters of an assessment that is both reliable and worthy of higher learning accreditation. Using grounded theory as a research method, we studied an e-assessment model that does not require physical…
A new approach to the measurement of pelvic asymmetry: proposed methods and reliability.
Gnat, Rafael; Biały, Maciej
2015-05-01
This is a methodological study presenting a novel method of pelvic asymmetry (PA) measurement for use in the research laboratory setting. The purpose of the study is (1) to establish intrarater and interrater reliability of the proposed measures of PA, (2) to verify the influence of repeated measurements on the reliability, and (3) to assess correlation between the proposed measures of PA. Twelve healthy volunteers participated, and 2 teams of raters were involved. Registration of anatomic landmarks' positions in the optical motion capture system was repeated 3 times. Two asymmetry indexes were calculated: for pelvic torsion and for lateral pelvic tilt. Interclass correlation coefficients (ICCs), standard errors of measurement, and smallest detectable differences were used to describe the intrarater and interrater reliability of the 2 indexes. After 2 repeated registrations of pelvic landmarks' positions, the reliability of our asymmetry indexes was good and excellent. The ICCs for intrarater reliability ranged from 0.96 to 0.97; the ICCs for interrater reliability ranged 0.81 to 0.90. There was moderate, nonsignificant correlation between asymmetry indexes for pelvis torsion and for lateral pelvic tilt (r = 0.45, P = .14). The 2 proposed asymmetry indexes showed good and excellent intrarater and interrater reliability after 2 repeated registrations of pelvic landmarks' positions and thus may be useful in the research laboratory setting. However, these indexes are not strongly correlated, which suggests that the 2 types of PA may constitute different clinical entities. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Pain, Liza A M; Baker, Ross; Sohail, Qazi Zain; Richardson, Denyse; Zabjek, Karl; Mogk, Jeremy P M; Agur, Anne M R
2018-03-23
Altered three-dimensional (3D) joint kinematics can contribute to shoulder pathology, including post-stroke shoulder pain. Reliable assessment methods enable comparative studies between asymptomatic shoulders of healthy subjects and painful shoulders of post-stroke subjects, and could inform treatment planning for post-stroke shoulder pain. The study purpose was to establish intra-rater test-retest reliability and within-subject repeatability of a palpation/digitization protocol, which assesses 3D clavicular/scapular/humeral rotations, in asymptomatic and painful post-stroke shoulders. Repeated measurements of 3D clavicular/scapular/humeral joint/segment rotations were obtained using palpation/digitization in 32 asymptomatic and six painful post-stroke shoulders during four reaching postures (rest/flexion/abduction/external rotation). Intra-class correlation coefficients (ICCs), standard error of the measurement and 95% confidence intervals were calculated. All ICC values indicated high to very high test-retest reliability (≥0.70), with lower reliability for scapular anterior/posterior tilt during external rotation in asymptomatic subjects, and scapular medial/lateral rotation, humeral horizontal abduction/adduction and axial rotation during abduction in post-stroke subjects. All standard error of measurement values demonstrated within-subject repeatability error ≤5° for all clavicular/scapular/humeral joint/segment rotations (asymptomatic ≤3.75°; post-stroke ≤5.0°), except for humeral axial rotation (asymptomatic ≤5°; post-stroke ≤15°). This noninvasive, clinically feasible palpation/digitization protocol was reliable and repeatable in asymptomatic shoulders, and in a smaller sample of painful post-stroke shoulders. Implications for Rehabilitation In the clinical setting, a reliable and repeatable noninvasive method for assessment of three-dimensional (3D) clavicular/scapular/humeral joint orientation and range of motion (ROM) is currently required. The established reliability and repeatability of this proposed palpation/digitization protocol will enable comparative 3D ROM studies between asymptomatic and post-stroke shoulders, which will further inform treatment planning. Intra-rater test-retest repeatability, which is measured by the standard error of the measure, indicates the range of error associated with a single test measure. Therefore, clinicians can use the standard error of the measure to determine the "true" differences between pre-treatment and post-treatment test scores.
Bu, Ri-E; Wang, Jin-Liang; Wu, Jin-Hua; Xilin, Gao-Wa; Chen, Jin-Long; Wang, Hua
2017-03-01
The aim of this study was to establish a rapid and accurate method for the detection of the Streptococcus agalactiae antibody (SA-Ab) to determine the presence of the bovine mastitis (BM)-causative pathogen. The multi-subunit fusion protein rSip-Pgk-FbsA was prokaryotically expressed and purified. The triple activities of the membrane surface-associated proteins Sip, phosphoglycerate kinase (Pgk), and fibronectin (FbsA) were used as the diagnostic antigens to establish an indirect enzyme-linked immunosorbent assay (ELISA) method for the detection of SA-Ab in BM. The optimal antigen coating concentration was 2 μg/mL, the optimal serum dilution was 1:160, and the optimal dilution of the enzyme-labeled secondary antibody was 1:6000. The sensitivity, specificity, and repeatability tests showed that the method established in this study had no cross-reaction with antibodies to Streptococcus pyogenes, Escherichia coli, Staphylococcus aureus, and Staphylococcus epidermidis in the sera. The results of the sensitivity test showed that a positive result could be obtained even if the serum dilution reached 1:12,800, indicating the high sensitivity and good repeatability of the method. The positive coincidence rate of this method was 98.6%, which is higher than that of previous tests established with the Sip or Pgk mono-antigen fusion protein, respectively, demonstrating the relatively higher sensitivity of this newly established method. The detection rate for 389 clinical samples was 46.53%. The indirect ELISA method established in this study could provide a more accurate and reliable serological method for the rapid detection of S. agalactiae in cases of BM.
On the short-term uncertainty in performance f a point absorber wave energy converter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coe, Ryan Geoffrey; Michelen, Carlos; Manuel, Lance
2016-03-01
Of interest, in this study, is the quantification of uncertainty in the performance of a two-body wave point absorber (Reference Model 3 or RM3), which serves as a wave energy converter (WEC). We demonstrate how simulation tools may be used to establish short-term relationships between any performance parameter of the WEC device and wave height in individual sea states. We demonstrate this methodology for two sea states. Efficient structural reliability methods, validated using more expensive Monte Carlo sampling, allow the estimation of uncertainty in performance of the device. Such methods, when combined with metocean data quantifying the likelihood of differentmore » sea states, can be useful in long-term studies and in reliability-based design.« less
NASA Astrophysics Data System (ADS)
Gromek, Katherine Emily
A novel computational and inference framework of the physics-of-failure (PoF) reliability modeling for complex dynamic systems has been established in this research. The PoF-based reliability models are used to perform a real time simulation of system failure processes, so that the system level reliability modeling would constitute inferences from checking the status of component level reliability at any given time. The "agent autonomy" concept is applied as a solution method for the system-level probabilistic PoF-based (i.e. PPoF-based) modeling. This concept originated from artificial intelligence (AI) as a leading intelligent computational inference in modeling of multi agents systems (MAS). The concept of agent autonomy in the context of reliability modeling was first proposed by M. Azarkhail [1], where a fundamentally new idea of system representation by autonomous intelligent agents for the purpose of reliability modeling was introduced. Contribution of the current work lies in the further development of the agent anatomy concept, particularly the refined agent classification within the scope of the PoF-based system reliability modeling, new approaches to the learning and the autonomy properties of the intelligent agents, and modeling interacting failure mechanisms within the dynamic engineering system. The autonomous property of intelligent agents is defined as agent's ability to self-activate, deactivate or completely redefine their role in the analysis. This property of agents and the ability to model interacting failure mechanisms of the system elements makes the agent autonomy fundamentally different from all existing methods of probabilistic PoF-based reliability modeling. 1. Azarkhail, M., "Agent Autonomy Approach to Physics-Based Reliability Modeling of Structures and Mechanical Systems", PhD thesis, University of Maryland, College Park, 2007.
[A simple and efficient method for establishing a mouse model of orthotopic MB49 bladder cancer].
Liang, Zhong-kun; Zhang, Lin; Hu, Zhi-ming; Chen, Zhong; Huang, Xin; Shi, Xiang-hua; Tan, Wan-long; Gao, Ji-min
2009-04-01
To establish a simple and efficient method for establishing a mouse model of orthotopic superficial bladder cancer. C57BL/6 mice were anesthetized with sodium pentobarbital and catheterized with modified IV catheter (24 G). The mice were intravesically pretreated with HCl and then with NaOH, and after washing the bladders with phosphate-buffered saline (PBS), 100 microl (1 x 10(7)) MB49 cells were infused and allowed to incubate in the bladder for 2 h followed intravesical mitomycin C (MMC) administration. The tumor formation rate, survival, gross hematuria, and bladder weight were determined as the outcome variables, and the pathology of the bladders was observed. Instillation of MB49 tumor cells resulted in a tumor formation rates of 100% in all the pretreated groups while 0% in the control group without pretreatment. MMC significantly reduced the bladder weight as compared to PBS. We have successfully established a stable, reproducible, and reliable orthotopic bladder cancer model in mice.
Yan, Yongqiu; Lu, Yu; Jiang, Shiping; Jiang, Yu; Tong, Yingpeng; Zuo, Limin; Yang, Jun; Gong, Feng; Zhang, Ling; Wang, Ping
2018-01-01
Background: Noni juice has been extensively used as folk medicine for the treatment of arthritis, infections, analgesic, colds, cancers, and diabetes by Polynesians for many years. Due to the lack of standard scientific evaluation methods, various kinds of commercial Noni juice with different quality and price were available on the market. Objective: To establish a sensitive, reliable, and accurate high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (HPLC-ESI-MS/MS) method for separation, identification, and simultaneous quantitative analysis of bioactive constituents in Noni juice. Materials and Methods: The analytes and eight batches of commercially available samples from different origins were separated and analyzed by the HPLC-ESI-MS/MS method on an Agilent ZORBAX SB-C18 (150 mm × 4.6 mm i.d., 5 μm) column using a gradient elution of acetonitrile-methanol-0.05% glacial acetic acid in water (v/v) at a constant flow rate of 0.5 mL/min. Results: Seven components were identification and all of the assay parameters were within the required limits. Components were within the correlation coefficient values (R2 ≥ 0.9993) at the concentration ranges tested. The precision of the assay method was <0.91% and the repeatability between 1.36% and 3.31%. The accuracy varied from 96.40% to 103.02% and the relative standard deviations of stability were <3.91%. Samples from the same origin showed similar content while different origins showed significant different result. Conclusions: The developed methods would provide a reliable basis and be useful in the establishment of a rational quality control standard of Noni juice. SUMMARY Separation, identification, and simultaneous quantitative analysis method of seven bioactive constituents in Noni juice is originally developed by high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometryThe presented method was successfully applied to the quality control of eight batches of commercially available samples of Noni juiceThis method is simple, sensitive, reliable, accurate, and efficient method with strong specificity, good precision, and high recovery rate and provides a reliable basis for quality control of Noni juice. Abbreviations used: HPLC-ESI-MS/MS: High-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry, LOD: Limit of detection, LOQ: Limit of quantitation, S/N: Signal-to-noise ratio, RSD: Relative standard deviations, DP: Declustering potential, CE: Collision energy, MRM: Multiple reaction monitoring, RT: Retention time. PMID:29576704
Evidence-based assessment in pediatric psychology: family measures.
Alderfer, Melissa A; Fiese, Barbara H; Gold, Jeffrey I; Cutuli, J J; Holmbeck, Grayson N; Goldbeck, Lutz; Chambers, Christine T; Abad, Mona; Spetter, Dante; Patterson, Joän
2008-10-01
To provide a review of the evidence base of family measures relevant to pediatric psychology. Twenty-nine family measures were selected based upon endorsement by Division 54 listserv members, expert judgment, and literature review. Spanning observational and self-report methods, the measures fell into three broad assessment categories: Family functioning, Dyadic family relationships, and Family functioning in the context of childhood chronic health conditions. Measures were categorized as: "Well-established", "Approaching well-established", or "Promising." Nineteen measures met "well-established" criteria and the remaining ten were "approaching well-established." "Well-established" measures were documented for each of the broad assessment categories named above. Many measures deemed "well-established" in the general population are proving to be reliable and useful in pediatric samples. More evidence of the validity of family measures is needed in this context. This review should prove helpful to clinicians and researchers as they strive to make evidence-based decisions regarding family measures.
Andreis, Elisabeth; Küllmer, Kai
2014-01-01
Self-monitoring of blood glucose (BG) by means of handheld BG systems is a cornerstone in diabetes therapy. The aim of this article is to describe a procedure with proven traceability for calibration and evaluation of BG systems to guarantee reliable BG measurements. Isotope dilution gas chromatography mass spectrometry (ID/GC/MS) is a method that fulfills all requirements to be used in a higher-order reference measurement procedure. However, this method is not applicable for routine measurements because of the time-consuming sample preparation. A hexokinase method with perchloric acid (PCA) sample pretreatment is used in a measurement procedure for such purposes. This method is directly linked to the ID/GC/MS method by calibration with a glucose solution that has an ID/GC/MS-determined target value. BG systems are calibrated with whole blood samples. The glucose levels in such samples are analyzed by this ID/GC/MS-linked hexokinase method to establish traceability to higher-order reference material. For method comparison, the glucose concentrations in 577 whole blood samples were measured using the PCA-hexokinase method and the ID/GC/MS method; this resulted in a mean deviation of 0.1%. The mean deviation between BG levels measured in >500 valid whole blood samples with BG systems and the ID/GC/MS was 1.1%. BG systems allow a reliable glucose measurement if a true reference measurement procedure, with a noninterrupted traceability chain using ID/GC/MS linked hexokinase method for calibration of BG systems, is implemented. Systems should be calibrated by means of a traceable and defined measurement procedure to avoid bias. PMID:24876614
A new real-time visual assessment method for faulty movement patterns during a jump-landing task.
Rabin, Alon; Levi, Ran; Abramowitz, Shai; Kozol, Zvi
2016-07-01
Determine the interrater reliability of a new real-time assessment of faulty movement patterns during a jump-landing task. Interrater reliability study. Human movement laboratory. 50 healthy females. Assessment included 6 items which were evaluated from a front and a side view. Two Physical Therapy students used a 9-point scale (0-8) to independently rate the quality of movement as good (0-2), moderate (3-5), or poor (6-8). Interrater reliability was expressed by percent agreement and weighted kappa. One examiner rated the quality of movement of 6 subjects as good, 34 subjects as moderate, and 10 subjects as poor. The second examiner rated the quality of movement of 12 subjects as good, 23 subjects as moderate, and 15 subjects as poor. Percent agreement and weighted kappa (95% confidence interval) were 78% and 0.68 (0.51, 0.85), respectively. A new real-time assessment of faulty movement patterns during jump-landing demonstrated adequate interrater reliability. Further study is warranted to validate this method against a motion analysis system, as well as to establish its predictive validity for injury. Copyright © 2015 Elsevier Ltd. All rights reserved.
Partnering to Establish and Study Simulation in International Nursing Education.
Garner, Shelby L; Killingsworth, Erin; Raj, Leena
The purpose of this article was to describe an international partnership to establish and study simulation in India. A pilot study was performed to determine interrater reliability among faculty new to simulation when evaluating nursing student competency performance. Interrater reliability was below the ideal agreement level. Findings in this study underscore the need to obtain baseline interrater reliability data before integrating competency evaluation into a simulation program.
Probabilistic Analysis of Space Shuttle Body Flap Actuator Ball Bearings
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Jett, Timothy R.; Predmore, Roamer E.; Zaretsky, Erin V.
2007-01-01
A probabilistic analysis, using the 2-parameter Weibull-Johnson method, was performed on experimental life test data from space shuttle actuator bearings. Experiments were performed on a test rig under simulated conditions to determine the life and failure mechanism of the grease lubricated bearings that support the input shaft of the space shuttle body flap actuators. The failure mechanism was wear that can cause loss of bearing preload. These tests established life and reliability data for both shuttle flight and ground operation. Test data were used to estimate the failure rate and reliability as a function of the number of shuttle missions flown. The Weibull analysis of the test data for a 2-bearing shaft assembly in each body flap actuator established a reliability level of 99.6 percent for a life of 12 missions. A probabilistic system analysis for four shuttles, each of which has four actuators, predicts a single bearing failure in one actuator of one shuttle after 22 missions (a total of 88 missions for a 4-shuttle fleet). This prediction is comparable with actual shuttle flight history in which a single actuator bearing was found to have failed by wear at 20 missions.
Probabilistic Analysis of Space Shuttle Body Flap Actuator Ball Bearings
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Jett, Timothy R.; Predmore, Roamer E.; Zaretsky, Erwin V.
2008-01-01
A probabilistic analysis, using the 2-parameter Weibull-Johnson method, was performed on experimental life test data from space shuttle actuator bearings. Experiments were performed on a test rig under simulated conditions to determine the life and failure mechanism of the grease lubricated bearings that support the input shaft of the space shuttle body flap actuators. The failure mechanism was wear that can cause loss of bearing preload. These tests established life and reliability data for both shuttle flight and ground operation. Test data were used to estimate the failure rate and reliability as a function of the number of shuttle missions flown. The Weibull analysis of the test data for the four actuators on one shuttle, each with a 2-bearing shaft assembly, established a reliability level of 96.9 percent for a life of 12 missions. A probabilistic system analysis for four shuttles, each of which has four actuators, predicts a single bearing failure in one actuator of one shuttle after 22 missions (a total of 88 missions for a 4-shuttle fleet). This prediction is comparable with actual shuttle flight history in which a single actuator bearing was found to have failed by wear at 20 missions.
Between Site Reliability of Startle Prepulse Inhibition Across Two Early Psychosis Consortia
Addington, Jean; Cannon, Tyrone D.; Cornblatt, Barbara A.; de la Fuente-Sandoval, Camilo; Mathalon, Dan H.; Perkins, Diana O.; Seidman, Larry J.; Tsuang, Ming; Walker, Elaine F.; Woods, Scott W.; Bachman, Peter; Belger, Ayse; Carrión, Ricardo E.; Donkers, Franc C.L.; Duncan, Erica; Johannesen, Jason; León-Ortiz, Pablo; Light, Gregory; Mondragón, Alejandra; Niznikiewicz, Margaret; Nunag, Jason; Roach, Brian J.; Solís-Vivanco, Rodolfo
2014-01-01
Prepulse inhibition (PPI) and reactivity of the acoustic startle response are widely used biobehavioral markers in psychopathology research. Previous studies have demonstrated that PPI and startle reactivity exhibit substantial within-site stability; between-site stability, however, has not been established. In two separate consortia investigating biomarkers of early psychosis, traveling subjects studies were performed as part of quality assurance procedures in order to assess the fidelity of data across sites. In the North American Prodromal Longitudinal Studies (NAPLS) Consortium, 8 normal subjects traveled to each of the 8 NAPLS sites and were tested twice at each site on the startle PPI paradigm. In preparation for a binational study, 10 healthy subjects were assessed twice in both San Diego and Mexico City. Intraclass correlations between and within sites were significant for PPI and startle response parameters, confirming the reliability of startle measures across sites in both consortia. There were between site differences in startle magnitude in the NAPLS study that did not appear to be related to methods or equipment. In planning multi-site studies, it is essential to institute quality assurance procedures early and establish between site reliability to assure comparable data across sites. PMID:23799460
1974-01-01
5.3 .7 131 United States .506.7 54,452 10.7 1.5 2704 --aGNF shown in this table is based on factor cost. This method of computation is used in NATO and...gives figures significantly different from those arrived at through the method’of computation normally used by U.S. economists. GNP at factor cost...in Table 5, page 31. This is true because once a reliable stateside source was established for an item, its management method changed from overseas
The establishment of insulin resistance model in FL83B and L6 cell
NASA Astrophysics Data System (ADS)
Liu, Lanlan; Han, Jizhong; Li, Haoran; Liu, Mengmeng; Zeng, Bin
2017-10-01
The insulin resistance models of mouse liver epithelial and rat myoblasts cells were induced by three kinds of inducers: dexamethasone, high insulin and high glucose. The purpose is to select the optimal insulin resistance model, to provide a simple and reliable TR cell model for the study of the pathogenesis of TR and the improvement of TR drugs and functional foods. The MTT method is used for toxicity screening of three compounds, selecting security and suitable concentration. We performed a Glucose oxidase peroxidase (GOD-POD) method involving FL83B and L6 cell with dexamethasone, high insulin and high glucose-induced insulin resistance. Results suggested that FL83B cells with dexamethasone-induced (0.25uM) were established insulin resistance and L6 cells with high-glucose (30mM) and dexamethasone-induced (0.25uM) were established insulin resistance.
18 CFR 39.3 - Electric Reliability Organization certification.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Electric Reliability... CERTIFICATION OF THE ELECTRIC RELIABILITY ORGANIZATION; AND PROCEDURES FOR THE ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.3 Electric Reliability Organization certification. (a) Any...
18 CFR 39.3 - Electric Reliability Organization certification.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Electric Reliability... CERTIFICATION OF THE ELECTRIC RELIABILITY ORGANIZATION; AND PROCEDURES FOR THE ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.3 Electric Reliability Organization certification. (a) Any...
18 CFR 39.3 - Electric Reliability Organization certification.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Electric Reliability... CERTIFICATION OF THE ELECTRIC RELIABILITY ORGANIZATION; AND PROCEDURES FOR THE ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.3 Electric Reliability Organization certification. (a) Any...
18 CFR 39.3 - Electric Reliability Organization certification.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Electric Reliability... CERTIFICATION OF THE ELECTRIC RELIABILITY ORGANIZATION; AND PROCEDURES FOR THE ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.3 Electric Reliability Organization certification. (a) Any...
New International Program to Asses the Reliability of Emerging Nondestructive Techniques (PARENT)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prokofiev, Iouri; Cumblidge, Stephen E.; Csontos, Aladar A.
2013-01-25
The Nuclear Regulatory Commission (NRC) established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) to follow on from the successful Program for the Inspection of Nickel alloy Components (PINC). The goal of the PARENT is to conduct a confirmatory assessment of the reliability of nondestructive evaluation (NDE) techniques for detecting and sizing primary water stress corrosion cracks (PWSCC) and applying the lessons learned from PINC to a series of round-robin tests. These open and blind round-robin tests will comprise a new set of typical pressure boundary components including dissimilar metal welds (DMWs) and bottom-mounted instrumentation penetrations. Openmore » round-robin tests will engage research and industry teams worldwide to investigate and demonstrate the reliability of emerging NDE techniques to detect and size flaws with a wide range of lengths, depths, orientations, and locations. Blind round-robin tests will utilize various testing organizations, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from relatively easy to very difficult for detection and sizing. Blind and open round-robin testing started in late 2011 and early 2012, respectively. This paper will present the work scope with reports on progress, NDE methods evaluated, and project timeline for PARENT.« less
Liang, Xianrui; Zhao, Cui; Su, Weike
2015-11-01
An ultra-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry method integrating multi-constituent determination and fingerprint analysis has been established for quality assessment and control of Scutellaria indica L. The optimized method possesses the advantages of speediness, efficiency, and allows multi-constituents determination and fingerprint analysis in one chromatographic run within 11 min. 36 compounds were detected, and 23 of them were unequivocally identified or tentatively assigned. The established fingerprint method was applied to the analysis of ten S. indica samples from different geographic locations. The quality assessment was achieved by using principal component analysis. The proposed method is useful and reliable for the characterization of multi-constituents in a complex chemical system and the overall quality assessment of S. indica. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lee, Bohyung; Weon, Jin Bae; Yun, Bo-Ra; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je
2014-01-01
Background: Tilia amurensis consists of various compounds, such as flavonoids and terpenoids. Objective: A simple and reliable high performance liquid chromatography (HPLC) coupled with the diode array detector (DAD) method has been established for simultaneous determination of epicatechin, nudiposide, lyoniside, and scopoletin isolated from Tilia amurensis. Materials and Methods: Optimum separations were obtained with a SHISEIDO C18 column by gradient eluton, with 0.1% Trifluoroacetic acid (TFA) water-methanol as the mobile phase. The gradient elution system was completed within 40 minutes. The flow rate and detection wavelength were 1 mL/minute, 205 nm, 250 nm, and 280 nm, respectively. Results: Validation of the analytical method was evaluated by linearity, precision, and the accuracy test. The calibration curve was linear over the established range with R2 > 0.997. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.01-15.20 μg/mL and 0.03-46.06 μg/mL. The method exhibited an intraday and interday precision range of 96.25-105.66% and 93.52-109.92%, respectively (RSD <2.80%). The recoveries and relative standard deviation (RSD) of the four compounds in Tilia amurensis were in the range of 90.42-104.84% and 0.2-2.58%. Conclusion: This developed method was accurate and reliable for the quality evaluation of the four compounds isolated from Tilia amurensis. PMID:25210303
NASA Technical Reports Server (NTRS)
Sargusingh, Miriam J.; Nelson, Jason R.
2014-01-01
NASA has highlighted reliability as critical to future human space exploration, particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However, no consensus has been reached on what is meant by improving on reliability, or on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the spring of 2013, the AES Water Recovery Project hosted a series of events at Johnson Space Center with the intended goal of establishing a common language and understanding of NASA's reliability goals, and equipping the projects with acceptable means of assessing the respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools, and techniques associated with evaluating and designing for system reliability. The campaign culminated in a workshop that included members of the Environmental Control and Life Support System and AES communities. The goal of this workshop was to develop a consensus on what reliability means to AES and identify methods for assessing low- to mid-technology readiness level technologies for reliability. This paper details the results of that workshop.
ECLSS Reliability for Long Duration Missions Beyond Lower Earth Orbit
NASA Technical Reports Server (NTRS)
Sargusingh, Miriam J.; Nelson, Jason
2014-01-01
Reliability has been highlighted by NASA as critical to future human space exploration particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However there is no consensus on what is meant by improving on reliability; nor on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the spring of 2013, the AES Water Recovery Project (WRP) hosted a series of events at the NASA Johnson Space Center (JSC) with the intended goal of establishing a common language and understanding of our reliability goals, and equipping the projects with acceptable means of assessing our respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools and techniques associated with evalauating and designing for system reliability. The campaign culminated in a workshop at JSC with members of the ECLSS and AES communities with the goal of developing a consensus on what reliability means to AES and identifying methods for assessing our low to mid-technology readiness level (TRL) technologies for reliability. This paper details the results of the workshop.
ECLSS Reliability for Long Duration Missions Beyond Lower Earth Orbit
NASA Technical Reports Server (NTRS)
Sargusingh, Miriam J.; Nelson, Jason
2014-01-01
Reliability has been highlighted by NASA as critical to future human space exploration particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However, there is no consensus on what is meant by improving on reliability; nor on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the Spring of 2013, the AES Water Recovery Project (WRP) hosted a series of events at the NASA Johnson Space Center (JSC) with the intended goal of establishing a common language and understanding of our reliability goals and equipping the projects with acceptable means of assessing our respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools and techniques associated with evaluating and designing for system reliability. The campaign culminated in a workshop at JSC with members of the ECLSS and AES communities with the goal of developing a consensus on what reliability means to AES and identifying methods for assessing our low to mid-technology readiness level (TRL) technologies for reliability. This paper details the results of the workshop.
Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire
Akmaz, Hazel Ekin; Uyar, Meltem; Kuzeyli Yıldırım, Yasemin; Akın Korhan, Esra
2018-01-01
Background: Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. Aims: To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Study Design: Methodological and cross sectional study. Methods: A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. Results: The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. Conclusion: The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance of chronic pain. PMID:29843496
Yan, Yongqiu; Lu, Yu; Jiang, Shiping; Jiang, Yu; Tong, Yingpeng; Zuo, Limin; Yang, Jun; Gong, Feng; Zhang, Ling; Wang, Ping
2018-01-01
Noni juice has been extensively used as folk medicine for the treatment of arthritis, infections, analgesic, colds, cancers, and diabetes by Polynesians for many years. Due to the lack of standard scientific evaluation methods, various kinds of commercial Noni juice with different quality and price were available on the market. To establish a sensitive, reliable, and accurate high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (HPLC-ESI-MS/MS) method for separation, identification, and simultaneous quantitative analysis of bioactive constituents in Noni juice. The analytes and eight batches of commercially available samples from different origins were separated and analyzed by the HPLC-ESI-MS/MS method on an Agilent ZORBAX SB-C 18 (150 mm × 4.6 mm i.d., 5 μm) column using a gradient elution of acetonitrile-methanol-0.05% glacial acetic acid in water (v/v) at a constant flow rate of 0.5 mL/min. Seven components were identification and all of the assay parameters were within the required limits. Components were within the correlation coefficient values ( R 2 ≥ 0.9993) at the concentration ranges tested. The precision of the assay method was <0.91% and the repeatability between 1.36% and 3.31%. The accuracy varied from 96.40% to 103.02% and the relative standard deviations of stability were <3.91%. Samples from the same origin showed similar content while different origins showed significant different result. The developed methods would provide a reliable basis and be useful in the establishment of a rational quality control standard of Noni juice. Separation, identification, and simultaneous quantitative analysis method of seven bioactive constituents in Noni juice is originally developed by high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometryThe presented method was successfully applied to the quality control of eight batches of commercially available samples of Noni juiceThis method is simple, sensitive, reliable, accurate, and efficient method with strong specificity, good precision, and high recovery rate and provides a reliable basis for quality control of Noni juice. Abbreviations used: HPLC-ESI-MS/MS: High-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry, LOD: Limit of detection, LOQ: Limit of quantitation, S/N: Signal-to-noise ratio, RSD: Relative standard deviations, DP: Declustering potential, CE: Collision energy, MRM: Multiple reaction monitoring, RT: Retention time.
Homann, Stefanie; Hofmann, Christian; Gorin, Aleksandr M.; Nguyen, Huy Cong Xuan; Huynh, Diana; Hamid, Phillip; Maithel, Neil; Yacoubian, Vahe; Mu, Wenli; Kossyvakis, Athanasios; Sen Roy, Shubhendu; Yang, Otto Orlean
2017-01-01
Transfection is one of the most frequently used techniques in molecular biology that is also applicable for gene therapy studies in humans. One of the biggest challenges to investigate the protein function and interaction in gene therapy studies is to have reliable monospecific detection reagents, particularly antibodies, for all human gene products. Thus, a reliable method that can optimize transfection efficiency based on not only expression of the target protein of interest but also the uptake of the nucleic acid plasmid, can be an important tool in molecular biology. Here, we present a simple, rapid and robust flow cytometric method that can be used as a tool to optimize transfection efficiency at the single cell level while overcoming limitations of prior established methods that quantify transfection efficiency. By using optimized ratios of transfection reagent and a nucleic acid (DNA or RNA) vector directly labeled with a fluorochrome, this method can be used as a tool to simultaneously quantify cellular toxicity of different transfection reagents, the amount of nucleic acid plasmid that cells have taken up during transfection as well as the amount of the encoded expressed protein. Finally, we demonstrate that this method is reproducible, can be standardized and can reliably and rapidly quantify transfection efficiency, reducing assay costs and increasing throughput while increasing data robustness. PMID:28863132
Reliability and validity in a nutshell.
Bannigan, Katrina; Watson, Roger
2009-12-01
To explore and explain the different concepts of reliability and validity as they are related to measurement instruments in social science and health care. There are different concepts contained in the terms reliability and validity and these are often explained poorly and there is often confusion between them. To develop some clarity about reliability and validity a conceptual framework was built based on the existing literature. The concepts of reliability, validity and utility are explored and explained. Reliability contains the concepts of internal consistency and stability and equivalence. Validity contains the concepts of content, face, criterion, concurrent, predictive, construct, convergent (and divergent), factorial and discriminant. In addition, for clinical practice and research, it is essential to establish the utility of a measurement instrument. To use measurement instruments appropriately in clinical practice, the extent to which they are reliable, valid and usable must be established.
NASA Astrophysics Data System (ADS)
Caillol, J. M.; Levesque, D.
1992-01-01
The reliability and the efficiency of a new method suitable for the simulations of dielectric fluids and ionic solutions is established by numerical computations. The efficiency depends on the use of a simulation cell which is the surface of a four-dimensional sphere. The reliability originates from a charge-charge potential solution of the Poisson equation in this confining volume. The computation time, for systems of a few hundred molecules, is reduced by a factor of 2 or 3 compared to this of a simulation performed in a cubic volume with periodic boundary conditions and the Ewald charge-charge potential.
Technology as the Enabler of a New Wave of Active Learning
ERIC Educational Resources Information Center
Rollag, Keith; Billsberry, Jon
2012-01-01
Education has always been slow on the uptake of new technology. Instructors have established time-worn methods of teaching, and the performance nature of the job puts an emphasis on reliability and predictability. The last thing an instructor wants to be doing is fumbling around trying to make something work in front of an audience of 200…
NASA Astrophysics Data System (ADS)
Gao, Chen; Ding, Zhongan; Deng, Bofa; Yan, Shengteng
2017-10-01
According to the characteristics of electric energy data acquire system (EEDAS), considering the availability of each index data and the connection between the index integrity, establishing the performance evaluation index system of electric energy data acquire system from three aspects as master station system, communication channel, terminal equipment. To determine the comprehensive weight of each index based on triangular fuzzy number analytic hierarchy process with entropy weight method, and both subjective preference and objective attribute are taken into consideration, thus realize the performance comprehensive evaluation more reasonable and reliable. Example analysis shows that, by combination with analytic hierarchy process (AHP) and triangle fuzzy numbers (TFN) to establish comprehensive index evaluation system based on entropy method, the evaluation results not only convenient and practical, but also more objective and accurate.
Lv, Jin-Li; Yang, Biao; Li, Meng-Xuan; Meng, Zhao-Qing; Ma, Shi-Ping; Wang, Zhen-Zhong; Ding, Gang; Huang, Wen-Zhe; Xiao, Wei
2017-03-01
To study Ginkgo biloba leaves in different producing area, we establish an HPLC method for the simultaneously determination of seven flavonoids glycosides and four biflavonoids in G. biloba leaves. The analysis was performed on an Agilent ZORBAX SB-C₁₈ column(4.6 mm×250 mm, 5 μm) wich acetonitrile, and 0.4% phosphoric acid as mobile phase at flow rate of 1 mL•min⁻¹ in a gradient edution, and the detection was carried out at 254 nm.The calibration curves of the seven flavonoids glycosides and four biflavonoids had a good linearitiy with good recoveries. The established HPLC method is simple, rapid, accurate, reliable, and sensitive, and can be applied to the identification and quality control of G. biloba leaves. Copyright© by the Chinese Pharmaceutical Association.
Griessenauer, Christoph J; Foreman, Paul; Shoja, Mohammadali M; Kicielinski, Kimberly P; Deveikis, John P; Walters, Beverly C; Harrigan, Mark R
2015-04-01
Traumatic aneurysms occur in up to 20% of blunt traumatic extracranial carotid artery injuries. Currently there is no standardized method for characterization of traumatic aneurysms. For the carotid and vertebral injury study (CAVIS), a prospective study of traumatic cerebrovascular injury, we established a method for aneurysm characterization and tested its reliability. Saccular aneurysm size was defined as the greatest linear distance between the expected location of the normal artery wall and the outer edge of the aneurysm lumen ("depth"). Fusiform aneurysm size was defined as the "depth" and longitudinal distance ("length") paralleling the normal artery. The size of the aneurysm relative to the normal artery was also assessed. Reliability measurements were made using four raters who independently reviewed 15 computed tomographic angiograms (CTAs) and 13 digital subtraction angiograms (DSAs) demonstrating a traumatic aneurysm of the internal carotid artery. Raters categorized the aneurysms as either "saccular" or "fusiform" and made measurements. Five scans of each imaging modality were repeated to evaluate intra-rater reliability. Fleiss's free-marginal multi-rater kappa (κ), Cohen's kappa (κ), and interclass correlation coefficient (ICC) determined inter- and intra-rater reliability. Inter-rater agreement as to the aneurysm "shape" was almost perfect for CTA (κ = 0.82) and DSA (κ = 0.897). Agreements on aneurysm "depth," "length," "aneurysm plus parent artery," and "parent artery" for CTA and DSA were excellent (ICC > 0.75). Intra-rater agreement as to aneurysm "shape" was substantial to almost perfect (κ > 0.60). The CAVIS method of traumatic aneurysm characterization has remarkable inter- and intra-rater reliability and will facilitate further studies of the natural history and management of extracranial cerebrovascular traumatic aneurysms. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Soliton and periodic solutions for time-dependent coefficient non-linear equation
NASA Astrophysics Data System (ADS)
Guner, Ozkan
2016-01-01
In this article, we establish exact solutions for the generalized (3+1)-dimensional variable coefficient Kadomtsev-Petviashvili (GVCKP) equation. Using solitary wave ansatz in terms of ? functions and the modified sine-cosine method, we find exact analytical bright soliton solutions and exact periodic solutions for the considered model. The physical parameters in the soliton solutions are obtained as function of the dependent model coefficients. The effectiveness and reliability of the method are shown by its application to the GVCKP equation.
Stovall, Bradley A; Kumar, Shrawan
2010-11-01
The objective of this review is to establish the current state of knowledge on the reliability of clinical assessment of asymmetry in the lumbar spine and pelvis. To search the literature, the authors consulted the databases of MEDLINE, CINAHL, AMED, MANTIS, Academic Search Complete, and Web of Knowledge using different combinations of the following keywords: palpation, asymmetry, inter or intraexaminer reliability, tissue texture, assessment, and anatomic landmark. Of the 23 studies identified, 14 did not meet the inclusion criteria and were excluded. The quality and methods of studies investigating the reliability of bony anatomic landmark asymmetry assessment are variable. The κ statistic ranges without training for interexaminer reliability were as follows: anterior superior iliac spine (ASIS), -0.01 to 0.19; posterior superior iliac spine (PSIS), 0.04 to 0.15; inferior lateral angle, transverse plane (ILA-A/P), -0.03 to 0.11; inferior lateral angles, coronal plane (ILA-S/I), -0.01 to 0.08; sacral sulcus (SS), -0.4 to 0.37; lumbar spine transverse processes L1 through L5, 0.04 to 0.17. The corresponding ranges for intraexaminer reliability were higher for all associated landmarks: ASIS, 0.19 to 0.4; PSIS, 0.13 to 0.49; ILA-A/P, 0.1 to 0.2; ILA-S/I, 0.03 to 0.21; SS, 0.24 to 0.28; lumbar spine transverse processes L1 through L5, not applicable. Further research is needed to better understand the reliability of asymmetry assessment methods in manipulative medicine.
Stovall, Bradley A.; Kumar, Shrawan
2011-01-01
The objective of this review is to establish the current state of knowledge on the reliability of clinical assessment of asymmetry in the lumbar spine and pelvis. To search the literature, the authors consulted the databases of MEDLINE, CINAHL, AMED, MANTIS, Academic Search Complete, and Web of Knowledge using different combinations of the following keywords: palpation, asymmetry, inter- or intraex-aminer reliability, tissue texture, assessment, and anatomic landmark. Of the 23 studies identified, 14 did not meet the inclusion criteria and were excluded. The quality and methods of studies investigating the reliability of bony anatomic landmark asymmetry assessment are variable. The κ statistic ranges without training for interexaminer reliability were as follows: anterior superior iliac spine (ASIS), −0.01 to 0.19; posterior superior iliac spine (PSIS), 0.04 to 0.15; inferior lateral angle, transverse plane (ILA-A/P), −0.03 to 0.11; inferior lateral angles, coronal plane (ILA-S/I), −0.01 to 0.08; sacral sulcus (SS), −0.4 to 0.37; lumbar spine transverse processes L1 through L5, 0.04 to 0.17. The corresponding ranges for intraexaminer reliability were higher for all associated landmarks: ASIS, 0.19 to 0.4; PSIS, 0.13 to 0.49; ILA-A/P, 0.1 to 0.2; ILA-S/I, 0.03 to 0.21; SS, 0.24 to 0.28; lumbar spine transverse processes L1 through L5, not applicable. Further research is needed to better understand the reliability of asymmetry assessment methods in manipulative medicine. PMID:21135198
Schiffman, Eric L; Truelove, Edmond L; Ohrbach, Richard; Anderson, Gary C; John, Mike T; List, Thomas; Look, John O
2010-01-01
The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. The aim of this article is to provide an overview of the project's methodology, descriptive statistics, and data for the study participant sample. This article also details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. The Axis I reference standards were based on the consensus of two criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion examination reliability was also assessed within study sites. Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas > or = 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion examiner agreement with reference standards was excellent (k > or = 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods.
Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E
2014-05-01
Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.
Content validity and reliability of test of gross motor development in Chilean children
Cano-Cappellacci, Marcelo; Leyton, Fernanda Aleitte; Carreño, Joshua Durán
2016-01-01
ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2) for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries. PMID:26815160
Validity and reliability of the Short Physical Performance Battery (SPPB)
Curcio, Carmen-Lucía; Alvarado, Beatriz; Zunzunegui, María Victoria; Guralnik, Jack
2013-01-01
Objectives: To assess the validity (convergent and construct) and reliability of the Short Physical Performance Battery (SPPB) among non-disabled adults between 65 to 74 years of age residing in the Andes Mountains of Colombia. Methods: Design Validation study; Participants: 150 subjects aged 65 to 74 years recruited from elderly associations (day-centers) in Manizales, Colombia. Measurements: The SPPB tests of balance, including time to walk 4 meters and time required to stand from a chair 5 times were administered to all participants. Reliability was analyzed with a 7-day interval between assessments and use of repeated ANOVA testing. Construct validity was assessed using factor analysis and by testing the relationship between SPPB and depressive symptoms, cognitive function, and self rated health (SRH), while the concurrent validity was measured through relationships with mobility limitations and disability in Activities of Daily Living (ADL). ANOVA tests were used to establish these associations. Results: Test-retest reliability of the SPPB was high: 0.87 (CI95%: 0.77-0.96). A one factor solution was found with three SPPB tests. SPPB was related to self-rated health, limitations in walking and climbing steps and to indicators of disability, as well as to cognitive function and depression. There was a graded decrease in the mean SPPB score with increasing disability and poor health. Conclusion: The Spanish version of SPPB is reliable and valid to assess physical performance among older adults from our region. Future studies should establish their clinical applications and explore usage in population studies. PMID:24892614
Lauricella, Leticia L; Costa, Priscila B; Salati, Michele; Pego-Fernandes, Paulo M; Terra, Ricardo M
2018-06-01
Database quality measurement should be considered a mandatory step to ensure an adequate level of confidence in data used for research and quality improvement. Several metrics have been described in the literature, but no standardized approach has been established. We aimed to describe a methodological approach applied to measure the quality and inter-rater reliability of a regional multicentric thoracic surgical database (Paulista Lung Cancer Registry). Data from the first 3 years of the Paulista Lung Cancer Registry underwent an audit process with 3 metrics: completeness, consistency, and inter-rater reliability. The first 2 methods were applied to the whole data set, and the last method was calculated using 100 cases randomized for direct auditing. Inter-rater reliability was evaluated using percentage of agreement between the data collector and auditor and through calculation of Cohen's κ and intraclass correlation. The overall completeness per section ranged from 0.88 to 1.00, and the overall consistency was 0.96. Inter-rater reliability showed many variables with high disagreement (>10%). For numerical variables, intraclass correlation was a better metric than inter-rater reliability. Cohen's κ showed that most variables had moderate to substantial agreement. The methodological approach applied to the Paulista Lung Cancer Registry showed that completeness and consistency metrics did not sufficiently reflect the real quality status of a database. The inter-rater reliability associated with κ and intraclass correlation was a better quality metric than completeness and consistency metrics because it could determine the reliability of specific variables used in research or benchmark reports. This report can be a paradigm for future studies of data quality measurement. Copyright © 2018 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Developing an oropharyngeal cancer (OPC) knowledge and behaviors survey.
Dodd, Virginia J; Riley Iii, Joseph L; Logan, Henrietta L
2012-09-01
To use the community participation research model to (1) develop a survey assessing knowledge about mouth and throat cancer and (2) field test and establish test-retest reliability with newly developed instrument. Cognitive interviews with primarily rural African American adults to assess their perception and interpretation of survey items. Test-retest reliability was established with a racially diverse rural population. Test-retest reliabilities ranged from .79 to .40 for screening awareness and .74 to .19 for knowledge. Coefficients increased for composite scores. Community participation methodology provided a culturally appropriate survey instrument that demonstrated acceptable levels of reliability.
Reliability generalization: a viable key for establishing validity generalization
NASA Technical Reports Server (NTRS)
Kennedy, R. S.; Turnage, J. J.
1991-01-01
Even with radical restriction of range, reliability coefficients from 10 studies gave an average interstudy value of .74, suggesting constancy of reliability over diverse experiments. A value from a new test can help index reliability of tests not previously studied.
Validation of a new classification system for skin tears.
LeBlanc, Kimberly; Baranoski, Sharon; Holloway, Samantha; Langemo, Diane
2013-06-01
The aim of this study was to validate and establish reliability of the International Skin Tear classification system. A consensus panel of 12 internationally recognized key opinion leaders convened in 2011 to establish consensus statements on the prevention, prediction, assessment, and treatment of skin tears. Subsequently, a new skin tear classification system was proposed. The system was then tested for interrater and intrarater reliability between the experts before being tested more widely on a sample of 327 individuals from the United States, Canada, and Europe. The results of the study indicated a substantial level of agreement for the expert panel (Fleiss κ = 0.619; 2-month follow-up = 0.653). Intrarater reliability was high (Cohen κ = 0.877). Interrater reliability was moderate (Fleiss κ = 0.555) for healthcare professionals (n = 303) and fair for non-health professionals (Fleiss κ = 0.338; n = 24). This international study established the reliability and validity of a new classification system for skin tears.
Cyber Physical Systems for User Reliability Measurements in a Sharing Economy Environment
Seo, Aria; Kim, Yeichang
2017-01-01
As the sharing economic market grows, the number of users is also increasing but many problems arise in terms of reliability between providers and users in the processing of services. The existing methods provide shared economic systems that judge the reliability of the provider from the viewpoint of the user. In this paper, we have developed a system for establishing mutual trust between providers and users in a shared economic environment to solve existing problems. In order to implement a system that can measure and control users’ situation in a shared economic environment, we analyzed the necessary factors in a cyber physical system (CPS). In addition, a user measurement system based on a CPS structure in a sharing economic environment is implemented through analysis of the factors to consider when constructing a CPS. PMID:28805709
Cyber Physical Systems for User Reliability Measurements in a Sharing Economy Environment.
Seo, Aria; Jeong, Junho; Kim, Yeichang
2017-08-13
As the sharing economic market grows, the number of users is also increasing but many problems arise in terms of reliability between providers and users in the processing of services. The existing methods provide shared economic systems that judge the reliability of the provider from the viewpoint of the user. In this paper, we have developed a system for establishing mutual trust between providers and users in a shared economic environment to solve existing problems. In order to implement a system that can measure and control users' situation in a shared economic environment, we analyzed the necessary factors in a cyber physical system (CPS). In addition, a user measurement system based on a CPS structure in a sharing economic environment is implemented through analysis of the factors to consider when constructing a CPS.
Surface electromyography as a screening method for evaluation of dysphagia and odynophagia
Vaiman, Michael; Eviatar, Ephraim
2009-01-01
Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090
Test-Retest Reliability of Diffusion Tensor Imaging in Huntington's Disease.
Cole, James H; Farmer, Ruth E; Rees, Elin M; Johnson, Hans J; Frost, Chris; Scahill, Rachael I; Hobbs, Nicola Z
2014-03-21
Diffusion tensor imaging (DTI) has shown microstructural abnormalities in patients with Huntington's Disease (HD) and work is underway to characterise how these abnormalities change with disease progression. Using methods that will be applied in longitudinal research, we sought to establish the reliability of DTI in early HD patients and controls. Test-retest reliability, quantified using the intraclass correlation coefficient (ICC), was assessed using region-of-interest (ROI)-based white matter atlas and voxelwise approaches on repeat scan data from 22 participants (10 early HD, 12 controls). T1 data was used to generate further ROIs for analysis in a reduced sample of 18 participants. The results suggest that fractional anisotropy (FA) and other diffusivity metrics are generally highly reliable, with ICCs indicating considerably lower within-subject compared to between-subject variability in both HD patients and controls. Where ICC was low, particularly for the diffusivity measures in the caudate and putamen, this was partly influenced by outliers. The analysis suggests that the specific DTI methods used here are appropriate for cross-sectional research in HD, and give confidence that they can also be applied longitudinally, although this requires further investigation. An important caveat for DTI studies is that test-retest reliability may not be evenly distributed throughout the brain whereby highly anisotropic white matter regions tended to show lower relative within-subject variability than other white or grey matter regions.
NASA Astrophysics Data System (ADS)
Wan, Fubin; Tan, Yuanyuan; Jiang, Zhenhua; Chen, Xun; Wu, Yinong; Zhao, Peng
2017-12-01
Lifetime and reliability are the two performance parameters of premium importance for modern space Stirling-type pulse tube refrigerators (SPTRs), which are required to operate in excess of 10 years. Demonstration of these parameters provides a significant challenge. This paper proposes a lifetime prediction and reliability estimation method that utilizes accelerated degradation testing (ADT) for SPTRs related to gaseous contamination failure. The method was experimentally validated via three groups of gaseous contamination ADT. First, the performance degradation model based on mechanism of contamination failure and material outgassing characteristics of SPTRs was established. Next, a preliminary test was performed to determine whether the mechanism of contamination failure of the SPTRs during ADT is consistent with normal life testing. Subsequently, the experimental program of ADT was designed for SPTRs. Then, three groups of gaseous contamination ADT were performed at elevated ambient temperatures of 40 °C, 50 °C, and 60 °C, respectively and the estimated lifetimes of the SPTRs under normal condition were obtained through acceleration model (Arrhenius model). The results show good fitting of the degradation model with the experimental data. Finally, we obtained the reliability estimation of SPTRs through using the Weibull distribution. The proposed novel methodology enables us to take less than one year time to estimate the reliability of the SPTRs designed for more than 10 years.
A Conflict Management Scale for Pharmacy
Gregory, Paul A.; Martin, Craig
2009-01-01
Objectives To develop and establish the validity and reliability of a conflict management scale specific to pharmacy practice and education. Methods A multistage inventory-item development process was undertaken involving 93 pharmacists and using a previously described explanatory model for conflict in pharmacy practice. A 19-item inventory was developed, field tested, and validated. Results The conflict management scale (CMS) demonstrated an acceptable degree of reliability and validity for use in educational or practice settings to promote self-reflection and self-awareness regarding individuals' conflict management styles. Conclusions The CMS provides a unique, pharmacy-specific method for individuals to determine and reflect upon their own conflict management styles. As part of an educational program to facilitate self-reflection and heighten self-awareness, the CMS may be a useful tool to promote discussions related to an important part of pharmacy practice. PMID:19960081
Falaggis, Konstantinos; Towers, David P; Towers, Catherine E
2012-09-20
Multiwavelength interferometry (MWI) is a well established technique in the field of optical metrology. Previously, we have reported a theoretical analysis of the method of excess fractions that describes the mutual dependence of unambiguous measurement range, reliability, and the measurement wavelengths. In this paper wavelength, selection strategies are introduced that are built on the theoretical description and maximize the reliability in the calculated fringe order for a given measurement range, number of wavelengths, and level of phase noise. Practical implementation issues for an MWI interferometer are analyzed theoretically. It is shown that dispersion compensation is best implemented by use of reference measurements around absolute zero in the interferometer. Furthermore, the effects of wavelength uncertainty allow the ultimate performance of an MWI interferometer to be estimated.
Validity and reliability of a scale to measure genital body image.
Zielinski, Ruth E; Kane-Low, Lisa; Miller, Janis M; Sampselle, Carolyn
2012-01-01
Women's body image dissatisfaction extends to body parts usually hidden from view--their genitals. Ability to measure genital body image is limited by lack of valid and reliable questionnaires. We subjected a previously developed questionnaire, the Genital Self Image Scale (GSIS) to psychometric testing using a variety of methods. Five experts determined the content validity of the scale. Then using four participant groups, factor analysis was performed to determine construct validity and to identify factors. Further construct validity was established using the contrasting groups approach. Internal consistency and test-retest reliability was determined. Twenty one of 29 items were considered content valid. Two items were added based on expert suggestions. Factor analysis was undertaken resulting in four factors, identified as Genital Confidence, Appeal, Function, and Comfort. The revised scale (GSIS-20) included 20 items explaining 59.4% of the variance. Women indicating an interest in genital cosmetic surgery exhibited significantly lower scores on the GSIS-20 than those who did not. The final 20 item scale exhibited internal reliability across all sample groups as well as test-retest reliability. The GSIS-20 provides a measure of genital body image demonstrating reliability and validity across several populations of women.
NASA Astrophysics Data System (ADS)
Kamiaka, Shoya; Benomar, Othman; Suto, Yasushi
2018-05-01
Advances in asteroseismology of solar-like stars, now provide a unique method to estimate the stellar inclination i⋆. This enables to evaluate the spin-orbit angle of transiting planetary systems, in a complementary fashion to the Rossiter-McLaughlineffect, a well-established method to estimate the projected spin-orbit angle λ. Although the asteroseismic method has been broadly applied to the Kepler data, its reliability has yet to be assessed intensively. In this work, we evaluate the accuracy of i⋆ from asteroseismology of solar-like stars using 3000 simulated power spectra. We find that the low signal-to-noise ratio of the power spectra induces a systematic under-estimate (over-estimate) bias for stars with high (low) inclinations. We derive analytical criteria for the reliable asteroseismic estimate, which indicates that reliable measurements are possible in the range of 20° ≲ i⋆ ≲ 80° only for stars with high signal-to-noise ratio. We also analyse and measure the stellar inclination of 94 Kepler main-sequence solar-like stars, among which 33 are planetary hosts. According to our reliability criteria, a third of them (9 with planets, 22 without) have accurate stellar inclination. Comparison of our asteroseismic estimate of vsin i⋆ against spectroscopic measurements indicates that the latter suffers from a large uncertainty possibly due to the modeling of macro-turbulence, especially for stars with projected rotation speed vsin i⋆ ≲ 5km/s. This reinforces earlier claims, and the stellar inclination estimated from the combination of measurements from spectroscopy and photometric variation for slowly rotating stars needs to be interpreted with caution.
Gao, L; Mao, C; Yu, G Y; Peng, X
2016-10-09
Objective: To translate the adult comorbidity evaluation-27(ACE-27) index authored by professor JF Piccirillo into Chinese and for the purpose of assessing the possible impact of comorbidity on survival of oral cancer patients and improving cancer staging. Methods: The translation included the following steps, obtaining permission from professor Piccirillo, translation, back translation, language modification, adjusted by the advice from the professors of oral and maxillofacial surgery. The test population included 154 patients who were admitted to Peking University of Stomatology during March 2011. Questionnaire survey was conducted on these patients. Retest of reliability, internal consistency reliability, content validity, and structure validity were performed. Results: The simplified Chinese ACE-27 index was established. The Cronbach's α was 0.821 in the internal consistency reliability test. The Kaiser-Meyer-Olkin (KMO) value of 8 items was 0.859 in the structure validity test. Conclusions: The simplified Chinese ACE-27 index has good feasibility and reliability. It is useful to assess the comorbidity of oral cancer patients.
Malisova, Olga; Bountziouka, Vassiliki; Panagiotakos, Demosthenes B; Zampelas, Antonis; Kapsokefalou, Maria
2012-03-01
There is a need to develop a questionnaire as a research tool for the evaluation of water balance in the general population. The water balance questionnaire (WBQ) was designed to evaluate water intake from fluid and solid foods and drinking water, and water loss from urine, faeces and sweat at sedentary conditions and physical activity. For validation purposes, the WBQ was administrated in 40 apparently healthy participants aged 22-57 years (37.5% males). Hydration indices in urine (24 h volume, osmolality, specific gravity, pH, colour) were measured through established procedures. Furthermore, the questionnaire was administered twice to 175 subjects to evaluate its reliability. Kendall's τ-b and the Bland and Altman method were used to assess the questionnaire's validity and reliability. The proposed WBQ to assess water balance in healthy individuals was found to be valid and reliable, and it could thus be a useful tool in future projects that aim to evaluate water balance.
10 CFR 712.19 - Removal from HRP.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the Human Reliability Program... immediately remove that individual from HRP duties pending a determination of the individual's reliability. A... HRP duties pending a determination of the individual's reliability is an interim, precautionary action...
Testing for Soluble ST2 in Heart Failure Patients: Reliability of a Point of Care Method.
Gruson, Damien; Ferracin, Benjamin; Ahn, Sylvie A; Rousseau, Michel F
2017-01-01
Our objective was to determine soluble ST2 (sST2) concentrations in heart failure (HF) patients with a point-of-care (POCT) assay. sST2 levels were measured in 71 HF patients with both POCT and ELISA methods. The concentrations of sST2 were correlated to HF severity and to some established biomarkers of cardiovascular risk. sST2 levels measured with the ASPECT-PLUS POCT method were significantly correlated with the comparison ELISA assay (r = 0.94, p < 0.01) and were related to HF severity. Levels of sST2 measured with the POCT assay were significantly correlated to NT-proBNP (r = 0.57, p < 0.001), BNP (r = 0.75, p < 0.001), Galectin-3 (r = 0.40, p < 0.01) and PTH (1-84) (r = 0.39, p < 0.01). POCT and ELISA methods for sST2 testing were significantly correlated, and our results confirmed also the clinical reliability of the sST2 POCT assay. Furthermore, the POCT method allows a faster delivery of results to physicians.
Safety, reliability, maintainability and quality provisions for the Space Shuttle program
NASA Technical Reports Server (NTRS)
1990-01-01
This publication establishes common safety, reliability, maintainability and quality provisions for the Space Shuttle Program. NASA Centers shall use this publication both as the basis for negotiating safety, reliability, maintainability and quality requirements with Shuttle Program contractors and as the guideline for conduct of program safety, reliability, maintainability and quality activities at the Centers. Centers shall assure that applicable provisions of the publication are imposed in lower tier contracts. Centers shall give due regard to other Space Shuttle Program planning in order to provide an integrated total Space Shuttle Program activity. In the implementation of safety, reliability, maintainability and quality activities, consideration shall be given to hardware complexity, supplier experience, state of hardware development, unit cost, and hardware use. The approach and methods for contractor implementation shall be described in the contractors safety, reliability, maintainability and quality plans. This publication incorporates provisions of NASA documents: NHB 1700.1 'NASA Safety Manual, Vol. 1'; NHB 5300.4(IA), 'Reliability Program Provisions for Aeronautical and Space System Contractors'; and NHB 5300.4(1B), 'Quality Program Provisions for Aeronautical and Space System Contractors'. It has been tailored from the above documents based on experience in other programs. It is intended that this publication be reviewed and revised, as appropriate, to reflect new experience and to assure continuing viability.
Gregory, T Ryan; Nathwani, Paula; Bonnett, Tiffany R; Huber, Dezene P W
2013-09-01
A study was undertaken to evaluate both a pre-existing method and a newly proposed approach for the estimation of nuclear genome sizes in arthropods. First, concerns regarding the reliability of the well-established method of flow cytometry relating to impacts of rearing conditions on genome size estimates were examined. Contrary to previous reports, a more carefully controlled test found negligible environmental effects on genome size estimates in the fly Drosophila melanogaster. Second, a more recently touted method based on quantitative real-time PCR (qPCR) was examined in terms of ease of use, efficiency, and (most importantly) accuracy using four test species: the flies Drosophila melanogaster and Musca domestica and the beetles Tribolium castaneum and Dendroctonus ponderosa. The results of this analysis demonstrated that qPCR has the tendency to produce substantially different genome size estimates from other established techniques while also being far less efficient than existing methods.
NASA Astrophysics Data System (ADS)
Lin, Xiangyue; Peng, Minli; Lei, Fengming; Tan, Jiangxian; Shi, Huacheng
2017-12-01
Based on the assumptions of uniform corrosion and linear elastic expansion, an analytical model of cracking due to rebar corrosion expansion in concrete was established, which is able to consider the structure internal force. And then, by means of the complex variable function theory and series expansion technology established by Muskhelishvili, the corresponding stress component functions of concrete around the reinforcement were obtained. Also, a comparative analysis was conducted between the numerical simulation model and present model in this paper. The results show that the calculation results of both methods were consistent with each other, and the numerical deviation was less than 10%, proving that the analytical model established in this paper is reliable.
NASA Technical Reports Server (NTRS)
Alexander, R. H. (Principal Investigator); Mcginty, H. K., III
1975-01-01
The author has identified the following significant results. Recommendations resulting from the CARETS evaluation reflect the need to establish a flexible and reliable system for providing more detailed raw and processed land resource information as well as the need to improve the methods of making information available to users.
Facility Systems, Ground Support Systems, and Ground Support Equipment General Design Requirements
NASA Technical Reports Server (NTRS)
Thaxton, Eric A.; Mathews, Roger E.
2014-01-01
This standard establishes requirements and guidance for design and fabrication of ground systems (GS) that includes: ground support equipment (GSE), ground support systems (GSS), and facility ground support systems (F GSS) to provide uniform methods and processes for design and development of robust, safe, reliable, maintainable, supportable, and cost-effective GS in support of space flight and institutional programs and projects.
ERIC Educational Resources Information Center
Epcacan, Cevdet
2013-01-01
The objective of this research is to establish the opinions of teachers and candidate teachers on the effect of creative drama. Descriptive research method is used in line with the objective of the research. Questionnaire is used for collecting data for the research. Questionnaire was prepared by the researcher. For the reliability of the…
ERIC Educational Resources Information Center
Al-Motlaq, Mohammad A.; Abuidhail, Jamila; Salameh, Taghreed; Awwad, Wesam
2017-01-01
Objective: To develop an instrument to study family-centred care (FCC) in traditional open bay Neonatal Intensive Care Units (NICUs). Methods: The development process involved constructing instrument's items, establishing content validity by an expert panel and testing the instrument for validity and reliability with a convenience sample of 25…
USSR and Eastern Europe Scientific Abstracts Geophysics, Astronomy and Space No. 404
1977-09-01
atmospheric circulation. A reliable linear correlation was established between the monthly fallout activity of 10^Ru + -^Rh and monthly precipitation and...therefore the washing out of this radionuclide from tropospheric air by precipitation is more important for its fallout. [153] ANALYTICAL...development of some methods for predicting definite weather phenomena (such as precipitation ), taking into account the evolution of the
Keserue, Hans-Anton; Füchslin, Hans Peter; Egli, Thomas
2011-01-01
Giardia lamblia is an important waterborne pathogen and is among the most common intestinal parasites of humans worldwide. Its fecal-oral transmission leads to the presence of cysts of this pathogen in the environment, and so far, quantitative rapid screening methods are not available for various matrices, such as surface waters, wastewater, or food. Thus, it is necessary to establish methods that enable reliable rapid detection of a single cyst in 10 to 100 liters of drinking water. Conventional detection relies on cyst concentration, isolation, and confirmation by immunofluorescence microscopy (IFM), resulting in low recoveries and high detection limits. Many different immunomagnetic separation (IMS) procedures have been developed for separation and cyst purification, so far with variable but high losses of cysts. A method was developed that requires less than 100 min and consists of filtration, resuspension, IMS, and flow cytometric (FCM) detection. MACS MicroBeads were used for IMS, and a reliable flow cytometric detection approach was established employing 3 different parameters for discrimination from background signals, i.e., green and red fluorescence (resulting from the distinct pattern emitted by the fluorescein dye) and sideward scatter for size discrimination. With spiked samples, recoveries exceeding 90% were obtained, and false-positive results were never encountered for negative samples. Additionally, the method was applicable to naturally occurring cysts in wastewater and has the potential to be automated. PMID:21685159
NASA Technical Reports Server (NTRS)
Robinson, E. A.
1973-01-01
Quality, reliability, and design standards for microwave hybrid microcircuits were established. The MSFC Standard 85M03926 for hybrid microcircuits was reviewed and modifications were generated for use with microwave hybrid microcircuits. The results for reliability tests of microwave thin film capacitors, transistors, and microwave circuits are presented. Twenty-two microwave receivers were tested for 13,500 unit hours. The result of 111,121 module burn-in and operating hours for an integrated solid state transceiver module is reported.
Muir-Hunter, Susan W; Graham, Laura; Montero Odasso, Manuel
2015-08-01
To measure test-retest and interrater reliability of the Berg Balance Scale (BBS) in community-dwelling adults with mild to moderate Alzheimer disease (AD). Method : A sample of 15 adults (mean age 80.20 [SD 5.03] years) with AD performed three balance tests: the BBS, timed up-and-go test (TUG), and Functional Reach Test (FRT). Both relative reliability, using the intra-class correlation coefficient (ICC), and absolute reliability, using standard error of measurement (SEM) and minimal detectable change (MDC95) values, were calculated; Bland-Altman plots were constructed to evaluate inter-tester agreement. The test-retest interval was 1 week. Results : For the BBS, relative reliability values were 0.95 (95% CI, 0.85-0.98) for test-retest reliability and 0.72 (95% CI, 0.31-0.91) for interrater reliability; SEM was 6.01 points and MDC95 was 16.66 points; and interrater agreement was 16.62 points. The BBS performed better in test-retest reliability than the TUG and FRT, tests with established reliability in AD. Between 33% and 50% of participants required cueing beyond standardized instructions because they were unable to remember test instructions. Conclusions : The BBS achieved relative reliability values that support its clinical utility, but MDC95 and agreement values indicate the scale has performance limitations in AD. Further research to optimize balance assessment for people with AD is required.
Aerospace Payloads Leak Test Methodology
NASA Technical Reports Server (NTRS)
Lvovsky, Oleg; Grayson, Cynthia M.
2010-01-01
Pressurized and sealed aerospace payloads can leak on orbit. When dealing with toxic or hazardous materials, requirements for fluid and gas leakage rates have to be properly established, and most importantly, reliably verified using the best Nondestructive Test (NDT) method available. Such verification can be implemented through application of various leak test methods that will be the subject of this paper, with a purpose to show what approach to payload leakage rate requirement verification is taken by the National Aeronautics and Space Administration (NASA). The scope of this paper will be mostly a detailed description of 14 leak test methods recommended.
Otis, Colombe; Gervais, Julie; Guillot, Martin; Gervais, Julie-Anne; Gauvin, Dominique; Péthel, Catherine; Authier, Simon; Dansereau, Marc-André; Sarret, Philippe; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Beaudry, Francis; Troncy, Eric
2016-06-23
Lack of validity in osteoarthritis pain models and assessment methods is suspected. Our goal was to 1) assess the repeatability and reproducibility of measurement and the influence of environment, and acclimatization, to different pain assessment outcomes in normal rats, and 2) test the concurrent validity of the most reliable methods in relation to the expression of different spinal neuropeptides in a chemical model of osteoarthritic pain. Repeatability and inter-rater reliability of reflexive nociceptive mechanical thresholds, spontaneous static weight-bearing, treadmill, rotarod, and operant place escape/avoidance paradigm (PEAP) were assessed by the intraclass correlation coefficient (ICC). The most reliable acclimatization protocol was determined by comparing coefficients of variation. In a pilot comparative study, the sensitivity and responsiveness to treatment of the most reliable methods were tested in the monosodium iodoacetate (MIA) model over 21 days. Two MIA (2 mg) groups (including one lidocaine treatment group) and one sham group (0.9 % saline) received an intra-articular (50 μL) injection. No effect of environment (observer, inverted circadian cycle, or exercise) was observed; all tested methods except mechanical sensitivity (ICC <0.3), offered good repeatability (ICC ≥0.7). The most reliable acclimatization protocol included five assessments over two weeks. MIA-related osteoarthritic change in pain was demonstrated with static weight-bearing, punctate tactile allodynia evaluation, treadmill exercise and operant PEAP, the latter being the most responsive to analgesic intra-articular lidocaine. Substance P and calcitonin gene-related peptide were higher in MIA groups compared to naive (adjusted P (adj-P) = 0.016) or sham-treated (adj-P = 0.029) rats. Repeated post-MIA lidocaine injection resulted in 34 times lower downregulation for spinal substance P compared to MIA alone (adj-P = 0.029), with a concomitant increase of 17 % in time spent on the PEAP dark side (indicative of increased comfort). This study of normal rats and rats with pain established the most reliable and sensitive pain assessment methods and an optimized acclimatization protocol. Operant PEAP testing was more responsive to lidocaine analgesia than other tests used, while neuropeptide spinal concentration is an objective quantification method attractive to support and validate different centralized pain functional assessment methods.
ORRISS, ISABEL R.; HAJJAWI, MARK O.R.; HUESA, CARMEN; MACRAE, VICKY E.; ARNETT, TIMOTHY R.
2014-01-01
The in vitro culture of calvarial osteoblasts from neonatal rodents remains an important method for studying the regulation of bone formation. The widespread use of transgenic mice has created a particular need for a reliable, simple method that allows the differentiation and bone-forming activity of murine osteoblasts to be studied. In the present study, we established such a method and identified key differences in optimal culture conditions between mouse and rat osteoblasts. Cells isolated from neonatal rodent calvariae by collagenase digestion were cultured for 14–28 days before staining for tissue non-specific alkaline phosphatase (TNAP) and bone mineralisation (alizarin red). The reliable differentiation of mouse osteoblasts, resulting in abundant TNAP expression and the formation of mineralised ‘trabecular-shaped’ bone nodules, occurred only following culture in α minimum essential medium (αMEM) and took 21–28 days. Dexamethasone (10 nM) inhibited bone mineralisation in the mouse osteoblasts. By contrast, TNAP expression and bone formation by rat osteoblasts were observed following culture in both αMEM and Dulbecco’s modified Eagle’s medium (DMEM) after approximately 14 days (although ~3-fold more effectively in αMEM) and was strongly dependent on dexamethasone. Both the mouse and rat osteoblasts required ascorbate (50 μg/ml) for osteogenic differentiation and β-glycerophosphate (2 mM) for mineralisation. The rat and mouse osteoblasts showed similar sensitivity to the well-established inhibitors of mineralisation, inorganic pyrophosphate (PPi) and adenosine triphosphate (ATP; 1–100 μM). The high efficiency of osteogenic differentiation observed following culture in αMEM, compared with culture in DMEM possibly reflects the richer formulation of the former. These findings offer a reliable technique for inducing mouse osteoblasts to form bone in vitro and a more effective method for culturing bone-forming rat osteoblasts. PMID:25200658
Some new exact solitary wave solutions of the van der Waals model arising in nature
NASA Astrophysics Data System (ADS)
Bibi, Sadaf; Ahmed, Naveed; Khan, Umar; Mohyud-Din, Syed Tauseef
2018-06-01
This work proposes two well-known methods, namely, Exponential rational function method (ERFM) and Generalized Kudryashov method (GKM) to seek new exact solutions of the van der Waals normal form for the fluidized granular matter, linked with natural phenomena and industrial applications. New soliton solutions such as kink, periodic and solitary wave solutions are established coupled with 2D and 3D graphical patterns for clarity of physical features. Our comparison reveals that the said methods excel several existing methods. The worked-out solutions show that the suggested methods are simple and reliable as compared to many other approaches which tackle nonlinear equations stemming from applied sciences.
Peak Detection Method Evaluation for Ion Mobility Spectrometry by Using Machine Learning Approaches
Hauschild, Anne-Christin; Kopczynski, Dominik; D’Addario, Marianna; Baumbach, Jörg Ingo; Rahmann, Sven; Baumbach, Jan
2013-01-01
Ion mobility spectrometry with pre-separation by multi-capillary columns (MCC/IMS) has become an established inexpensive, non-invasive bioanalytics technology for detecting volatile organic compounds (VOCs) with various metabolomics applications in medical research. To pave the way for this technology towards daily usage in medical practice, different steps still have to be taken. With respect to modern biomarker research, one of the most important tasks is the automatic classification of patient-specific data sets into different groups, healthy or not, for instance. Although sophisticated machine learning methods exist, an inevitable preprocessing step is reliable and robust peak detection without manual intervention. In this work we evaluate four state-of-the-art approaches for automated IMS-based peak detection: local maxima search, watershed transformation with IPHEx, region-merging with VisualNow, and peak model estimation (PME). We manually generated a gold standard with the aid of a domain expert (manual) and compare the performance of the four peak calling methods with respect to two distinct criteria. We first utilize established machine learning methods and systematically study their classification performance based on the four peak detectors’ results. Second, we investigate the classification variance and robustness regarding perturbation and overfitting. Our main finding is that the power of the classification accuracy is almost equally good for all methods, the manually created gold standard as well as the four automatic peak finding methods. In addition, we note that all tools, manual and automatic, are similarly robust against perturbations. However, the classification performance is more robust against overfitting when using the PME as peak calling preprocessor. In summary, we conclude that all methods, though small differences exist, are largely reliable and enable a wide spectrum of real-world biomedical applications. PMID:24957992
Peak detection method evaluation for ion mobility spectrometry by using machine learning approaches.
Hauschild, Anne-Christin; Kopczynski, Dominik; D'Addario, Marianna; Baumbach, Jörg Ingo; Rahmann, Sven; Baumbach, Jan
2013-04-16
Ion mobility spectrometry with pre-separation by multi-capillary columns (MCC/IMS) has become an established inexpensive, non-invasive bioanalytics technology for detecting volatile organic compounds (VOCs) with various metabolomics applications in medical research. To pave the way for this technology towards daily usage in medical practice, different steps still have to be taken. With respect to modern biomarker research, one of the most important tasks is the automatic classification of patient-specific data sets into different groups, healthy or not, for instance. Although sophisticated machine learning methods exist, an inevitable preprocessing step is reliable and robust peak detection without manual intervention. In this work we evaluate four state-of-the-art approaches for automated IMS-based peak detection: local maxima search, watershed transformation with IPHEx, region-merging with VisualNow, and peak model estimation (PME).We manually generated Metabolites 2013, 3 278 a gold standard with the aid of a domain expert (manual) and compare the performance of the four peak calling methods with respect to two distinct criteria. We first utilize established machine learning methods and systematically study their classification performance based on the four peak detectors' results. Second, we investigate the classification variance and robustness regarding perturbation and overfitting. Our main finding is that the power of the classification accuracy is almost equally good for all methods, the manually created gold standard as well as the four automatic peak finding methods. In addition, we note that all tools, manual and automatic, are similarly robust against perturbations. However, the classification performance is more robust against overfitting when using the PME as peak calling preprocessor. In summary, we conclude that all methods, though small differences exist, are largely reliable and enable a wide spectrum of real-world biomedical applications.
Veenstra, Richard D
2016-01-01
The development of the patch clamp technique has enabled investigators to directly measure gap junction conductance between isolated pairs of small cells with resolution to the single channel level. The dual patch clamp recording technique requires specialized equipment and the acquired skill to reliably establish gigaohm seals and the whole cell recording configuration with high efficiency. This chapter describes the equipment needed and methods required to achieve accurate measurement of macroscopic and single gap junction channel conductances. Inherent limitations with the dual whole cell recording technique and methods to correct for series access resistance errors are defined as well as basic procedures to determine the essential electrical parameters necessary to evaluate the accuracy of gap junction conductance measurements using this approach.
ERIC Educational Resources Information Center
Williams, Lunetta M.; Hall, Katrina W.; Hedrick, Wanda B.; Lamkin, Marcia; Abendroth, Jennifer
2013-01-01
The purpose of the present study was to develop an instrument to measure reading during in-school independent reading (ISIR). Procedures to establish validity and reliability of the instrument included videotaping and observing students during ISIR, gathering feedback from literacy experts, establishing interrater reliability, crosschecking…
Bullying Participant Behaviors Questionnaire (BPBQ): Establishing a Reliable and Valid Measure
ERIC Educational Resources Information Center
Demaray, Michelle Kilpatrick; Summers, Kelly Hodgson; Jenkins, Lyndsay N.; Becker, Lisa Davidson
2016-01-01
The current study further establishes the reliability and validity of the Bullying Participant Behaviors Questionnaire (BPBQ), a self-report survey that allows for an examination of participation in various bullying participant role behaviors including bully, assistant to the bully, victim, defender of the victim, and outsider. The study included…
Bridges, Patricia H; Carter, Vincent; Rehm, Stephanie; Tintl, Sara Bowers; Halperin, Rebecca; Kniesly, Elizabeth; Pelino, Soni
2013-01-01
Conduct a pilot study to establish the reliability and validity of a survey instrument that directly measures the objectives and content of the APTA CIECP; and measure the self-reported frequency of use of the behaviors taught in the APTA CIECP. Eighteen (18) APTA credentialed CIs. Develop a web-based survey consisting of 58 items representative of the behaviors taught in the APTA CIECP and 8 demographic characteristics. Establish the content validity and reliability of the survey instrument. Conduct a descriptive analysis of the frequency of self-reported use of the behaviors. The APTA Clinical Instructor Education Board (CIEB) reviewed the items and determined that the items matched the objectives and content of the APTA CIECP, thereby establishing content validity. Cronbach's alpha coefficients ranging from 0.79-0.90 confirmed the reliability. The overall mean for all items on a 1-6 scale was 4.81. The content validity and reliability of the survey instrument were established. The outcomes of this pilot study suggest that when measured by a valid and reliable instrument that is representative of the objectives and content of the CIECP, the behaviors taught in the CIECP are being applied in the clinical setting by APTA credentialed clinical instructors.
Reliability and validity of the neurorehabilitation experience questionnaire for inpatients.
Kneebone, Ian I; Hull, Samantha L; McGurk, Rhona; Cropley, Mark
2012-09-01
Patient-centered measures of the inpatient neurorehabilitation experience are needed to assess services. The objective of this study was to develop a valid and reliable Neurorehabilitation Experience Questionnaire (NREQ) to assess whether neurorehabilitation inpatients experience service elements important to them. Based on the themes established in prior qualitative research, adopting questions from established inventories and using a literature review, a draft version of the NREQ was generated. Focus groups and interviews were conducted with 9 patients and 26 staff from neurological rehabilitation units to establish face validity. Then, 70 patients were recruited to complete the NREQ to ascertain reliability (internal and test-retest) and concurrent validity. On the basis of the face validity testing, several modifications were made to the draft version of the NREQ. Subsequently, internal reliability (time 1 α = .76, time 2 α = .80), test retest reliability (r = 0.70), and concurrent validity (r = 0.32 and r = 0.56) were established for the revised version. Whereas responses were associated with positive mood (r = 0.30), they appeared not to be influenced by negative mood, age, education, length of stay, sex, functional independence, or whether a participant had been a patient on a unit previously. Preliminary validation of the NREQ suggests promise for use with its target population.
18 CFR 39.6 - Conflict of a Reliability Standard with a Commission Order.
Code of Federal Regulations, 2010 CFR
2010-04-01
... FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT RULES CONCERNING CERTIFICATION OF THE ELECTRIC RELIABILITY ORGANIZATION; AND PROCEDURES FOR THE ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.6 Conflict of a Reliability Standard with...
An advanced probabilistic structural analysis method for implicit performance functions
NASA Technical Reports Server (NTRS)
Wu, Y.-T.; Millwater, H. R.; Cruse, T. A.
1989-01-01
In probabilistic structural analysis, the performance or response functions usually are implicitly defined and must be solved by numerical analysis methods such as finite element methods. In such cases, the most commonly used probabilistic analysis tool is the mean-based, second-moment method which provides only the first two statistical moments. This paper presents a generalized advanced mean value (AMV) method which is capable of establishing the distributions to provide additional information for reliability design. The method requires slightly more computations than the second-moment method but is highly efficient relative to the other alternative methods. In particular, the examples show that the AMV method can be used to solve problems involving non-monotonic functions that result in truncated distributions.
Method Development in Forensic Toxicology.
Peters, Frank T; Wissenbach, Dirk K; Busardo, Francesco Paolo; Marchei, Emilia; Pichini, Simona
2017-01-01
In the field of forensic toxicology, the quality of analytical methods is of great importance to ensure the reliability of results and to avoid unjustified legal consequences. A key to high quality analytical methods is a thorough method development. The presented article will provide an overview on the process of developing methods for forensic applications. This includes the definition of the method's purpose (e.g. qualitative vs quantitative) and the analytes to be included, choosing an appropriate sample matrix, setting up separation and detection systems as well as establishing a versatile sample preparation. Method development is concluded by an optimization process after which the new method is subject to method validation. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Chang, Jasper O; Levy, Susan S; Seay, Seth W; Goble, Daniel J
2014-05-01
Recent guidelines advocate sports medicine professionals to use balance tests to assess sensorimotor status in the management of concussions. The present study sought to determine whether a low-cost balance board could provide a valid, reliable, and objective means of performing this balance testing. Criterion validity testing relative to a gold standard and 7 day test-retest reliability. University biomechanics laboratory. Thirty healthy young adults. Balance ability was assessed on 2 days separated by 1 week using (1) a gold standard measure (ie, scientific grade force plate), (2) a low-cost Nintendo Wii Balance Board (WBB), and (3) the Balance Error Scoring System (BESS). Validity of the WBB center of pressure path length and BESS scores were determined relative to the force plate data. Test-retest reliability was established based on intraclass correlation coefficients. Composite scores for the WBB had excellent validity (r = 0.99) and test-retest reliability (R = 0.88). Both the validity (r = 0.10-0.52) and test-retest reliability (r = 0.61-0.78) were lower for the BESS. These findings demonstrate that a low-cost balance board can provide improved balance testing accuracy/reliability compared with the BESS. This approach provides a potentially more valid/reliable, yet affordable, means of assessing sports-related concussion compared with current methods.
Quantitative metal magnetic memory reliability modeling for welded joints
NASA Astrophysics Data System (ADS)
Xing, Haiyan; Dang, Yongbin; Wang, Ben; Leng, Jiancheng
2016-03-01
Metal magnetic memory(MMM) testing has been widely used to detect welded joints. However, load levels, environmental magnetic field, and measurement noises make the MMM data dispersive and bring difficulty to quantitative evaluation. In order to promote the development of quantitative MMM reliability assessment, a new MMM model is presented for welded joints. Steel Q235 welded specimens are tested along the longitudinal and horizontal lines by TSC-2M-8 instrument in the tensile fatigue experiments. The X-ray testing is carried out synchronously to verify the MMM results. It is found that MMM testing can detect the hidden crack earlier than X-ray testing. Moreover, the MMM gradient vector sum K vs is sensitive to the damage degree, especially at early and hidden damage stages. Considering the dispersion of MMM data, the K vs statistical law is investigated, which shows that K vs obeys Gaussian distribution. So K vs is the suitable MMM parameter to establish reliability model of welded joints. At last, the original quantitative MMM reliability model is first presented based on the improved stress strength interference theory. It is shown that the reliability degree R gradually decreases with the decreasing of the residual life ratio T, and the maximal error between prediction reliability degree R 1 and verification reliability degree R 2 is 9.15%. This presented method provides a novel tool of reliability testing and evaluating in practical engineering for welded joints.
A multi-strategy approach to informative gene identification from gene expression data.
Liu, Ziying; Phan, Sieu; Famili, Fazel; Pan, Youlian; Lenferink, Anne E G; Cantin, Christiane; Collins, Catherine; O'Connor-McCourt, Maureen D
2010-02-01
An unsupervised multi-strategy approach has been developed to identify informative genes from high throughput genomic data. Several statistical methods have been used in the field to identify differentially expressed genes. Since different methods generate different lists of genes, it is very challenging to determine the most reliable gene list and the appropriate method. This paper presents a multi-strategy method, in which a combination of several data analysis techniques are applied to a given dataset and a confidence measure is established to select genes from the gene lists generated by these techniques to form the core of our final selection. The remainder of the genes that form the peripheral region are subject to exclusion or inclusion into the final selection. This paper demonstrates this methodology through its application to an in-house cancer genomics dataset and a public dataset. The results indicate that our method provides more reliable list of genes, which are validated using biological knowledge, biological experiments, and literature search. We further evaluated our multi-strategy method by consolidating two pairs of independent datasets, each pair is for the same disease, but generated by different labs using different platforms. The results showed that our method has produced far better results.
Fast Entanglement Establishment via Local Dynamics for Quantum Repeater Networks
NASA Astrophysics Data System (ADS)
Gyongyosi, Laszlo; Imre, Sandor
Quantum entanglement is a necessity for future quantum communication networks, quantum internet, and long-distance quantum key distribution. The current approaches of entanglement distribution require high-delay entanglement transmission, entanglement swapping to extend the range of entanglement, high-cost entanglement purification, and long-lived quantum memories. We introduce a fundamental protocol for establishing entanglement in quantum communication networks. The proposed scheme does not require entanglement transmission between the nodes, high-cost entanglement swapping, entanglement purification, or long-lived quantum memories. The protocol reliably establishes a maximally entangled system between the remote nodes via dynamics generated by local Hamiltonians. The method eliminates the main drawbacks of current schemes allowing fast entanglement establishment with a minimized delay. Our solution provides a fundamental method for future long-distance quantum key distribution, quantum repeater networks, quantum internet, and quantum-networking protocols. This work was partially supported by the GOP-1.1.1-11-2012-0092 project sponsored by the EU and European Structural Fund, by the Hungarian Scientific Research Fund - OTKA K-112125, and by the COST Action MP1006.
Mosmuller, David G M; Maal, Thomas J; Prahl, Charlotte; Tan, Robin A; Mulder, Frans J; Schwirtz, Roderic M F; de Vet, Henrica C W; Bergé, Stefaan J; Don Griot, J P W
2017-08-01
For the assessment of the nasolabial appearance in cleft patients, a widely accepted, reliable scoring system is not available. In this study four different methods of assessment are compared, including 2D and 3D asymmetry and aesthetic assessments. The data and ratings from an earlier study using the Asher-McDade aesthetic index on 3D photographs and the outcomes of 3D facial distance mapping were compared to a 2D aesthetic assessment, the Cleft Aesthetic Rating Scale, and to SymNose, a computerized 2D asymmetry assessment technique. The reliability and correlation between the four assessment techniques were tested using a sample of 79 patients. The 3D asymmetry assessment had the highest reliability and could be performed by just one observer (Intraclass correlation coefficient (ICC): 0.99). The 2D asymmetry assessment of the nose was highly reliable when performed by just one observer (ICC: 0.89). However, for the 2D asymmetry assessment of the lip more observers were needed. For the 2D aesthetic assessments 3 observers were needed. The 3D aesthetic assessment had the lowest single-observer reliability (ICC: 0.38-0.56) of all four techniques. The agreement between the different assessment methods is poor to very poor. The highest correlation (R: 0.48) was found between 2D and 3D aesthetic assessments. Remarkably, the lowest correlations were found between 2D and 3D asymmetry assessments (0.08-0.17). Different assessment methods are not in agreement and seem to measure different nasolabial aspects. More research is needed to establish exactly what each assessment technique measures and which measurements or outcomes are relevant for the patients. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Romi, Wahengbam; Keisam, Santosh; Ahmed, Giasuddin; Jeyaram, Kumaraswamy
2014-02-28
Meyerozyma guilliermondii (anamorph Candida guilliermondii) and Meyerozyma caribbica (anamorph Candida fermentati) are closely related species of the genetically heterogenous M. guilliermondii complex. Conventional phenotypic methods frequently misidentify the species within this complex and also with other species of the Saccharomycotina CTG clade. Even the long-established sequencing of large subunit (LSU) rRNA gene remains ambiguous. We also faced similar problem during identification of yeast isolates of M. guilliermondii complex from indigenous bamboo shoot fermentation in North East India. There is a need for development of reliable and accurate identification methods for these closely related species because of their increasing importance as emerging infectious yeasts and associated biotechnological attributes. We targeted the highly variable internal transcribed spacer (ITS) region (ITS1-5.8S-ITS2) and identified seven restriction enzymes through in silico analysis for differentiating M. guilliermondii from M. caribbica. Fifty five isolates of M. guilliermondii complex which could not be delineated into species-specific taxonomic ranks by API 20 C AUX and LSU rRNA gene D1/D2 sequencing were subjected to ITS-restriction fragment length polymorphism (ITS-RFLP) analysis. TaqI ITS-RFLP distinctly differentiated the isolates into M. guilliermondii (47 isolates) and M. caribbica (08 isolates) with reproducible species-specific patterns similar to the in silico prediction. The reliability of this method was validated by ITS1-5.8S-ITS2 sequencing, mitochondrial DNA RFLP and electrophoretic karyotyping. We herein described a reliable ITS-RFLP method for distinct differentiation of frequently misidentified M. guilliermondii from M. caribbica. Even though in silico analysis differentiated other closely related species of M. guilliermondii complex from the above two species, it is yet to be confirmed by in vitro analysis using reference strains. This method can be used as a reliable tool for rapid and accurate identification of closely related species of M. guilliermondii complex and for differentiating emerging infectious yeasts of the Saccharomycotina CTG clade.
Davoudi, Arash; Seighalani, Ramin; Aleyasin, Seyed Ahmad; Tarang, Alireza; Salehi, Abdolreza Salehi; Tahmoressi, Farideh
2012-04-01
In order to establish a reliable non-invasive method for sex determination in a bovine fetus in a routine setting, the possibility of identifying specific sequence in the fetal X and Y-chromosomes has been evaluated in maternal plasma using conventional multiplex polymerase chain reaction (PCR) analysis. The aim of this study was to provide a rapid and reliable method for sexing bovine fetuses. In this experimental study, peripheral blood samples were taken from 38 pregnant heifers with 8 to 38 weeks of gestation. DNA template was extracted by phenol-chloroform method from 350 µl maternal plasma. Two primer pairs for bovine amelogenin gene (bAML) and BC1.2 were used to amplify fragments from X and Y chromosomes. A multiplex PCR reaction has been optimized for amplification of 467 bp and 341 bp fragments from X and Y bAML gene and a 190 bp fragment from BC1.2 related to Y chromosome. The 467 bp fragment was observed in all 38 samples. Both 341 and 190 bp fragments were detected only in 24 plasma samples from male calves. The sensitivity and specificity of test were 100% with no false negative or false positive results. The results showed that phenol-chloroform method is a simple and suitable method for isolation of fetal DNA in maternal plasma. The multiplex PCR method is an available non-invasive approach which is cost efficient and reliable for sexing bovine fetuses.
System-reliability studies for wave-energy generation
NASA Astrophysics Data System (ADS)
Dawson, J. M.; Din, S.; Mytton, M. G.; Shore, N. L.; Stansfield, H. B.
1980-06-01
A study is reported that is being undertaken in the United Kingdom to determine means of developing the potential of the large wave-energy resource around the coast, in particular, that to the west facing the Atlantic. It is shown that derivation of the mean annual energy to be expected involved knowledge, not only of the wave climates, conversion efficiency characteristics of the proposed devices and of the power transmission system, but also of factors reflecting the availability overall. Attention is given to a simplified approach to the quantifying of reliability for each stage of the process. An appropriate method of analysis is established and a summary of the results obtained is given.
Santourlidis, Simeon; Ghanjati, Foued; Beermann, Agnes; Hermanns, Thomas; Poyet, Cédric
2016-02-01
Sensitive, accurate, and reliable measurements of tumor cell-specific DNA methylation changes are of fundamental importance in cancer diagnosis, prognosis, and monitoring. Real-time methylation-specific PCR (MSP) using intercalating dyes is an established method of choice for this purpose. Here we present a simple but crucial adaptation of this widely applied method that overcomes a major obstacle: genetic abnormalities in the DNA samples, such as aneuploidy or copy number variations, that could result in inaccurate results due to improper normalization if the copy numbers of the target and reference sequences are not the same. In our idiolocal normalization (IDLN) method, the locus for the normalizing, methylation-independent reference amplification is chosen close to the locus of the methylation-dependent target amplification. This ensures that the copy numbers of both the target and reference sequences will be identical in most cases if they are close enough to each other, resulting in accurate normalization and reliable comparative measurements of DNA methylation in clinical samples when using real-time MSP.
A method for analyzing clustered interval-censored data based on Cox's model.
Kor, Chew-Teng; Cheng, Kuang-Fu; Chen, Yi-Hau
2013-02-28
Methods for analyzing interval-censored data are well established. Unfortunately, these methods are inappropriate for the studies with correlated data. In this paper, we focus on developing a method for analyzing clustered interval-censored data. Our method is based on Cox's proportional hazard model with piecewise-constant baseline hazard function. The correlation structure of the data can be modeled by using Clayton's copula or independence model with proper adjustment in the covariance estimation. We establish estimating equations for the regression parameters and baseline hazards (and a parameter in copula) simultaneously. Simulation results confirm that the point estimators follow a multivariate normal distribution, and our proposed variance estimations are reliable. In particular, we found that the approach with independence model worked well even when the true correlation model was derived from Clayton's copula. We applied our method to a family-based cohort study of pandemic H1N1 influenza in Taiwan during 2009-2010. Using the proposed method, we investigate the impact of vaccination and family contacts on the incidence of pH1N1 influenza. Copyright © 2012 John Wiley & Sons, Ltd.
A strategy for evaluating pathway analysis methods.
Yu, Chenggang; Woo, Hyung Jun; Yu, Xueping; Oyama, Tatsuya; Wallqvist, Anders; Reifman, Jaques
2017-10-13
Researchers have previously developed a multitude of methods designed to identify biological pathways associated with specific clinical or experimental conditions of interest, with the aim of facilitating biological interpretation of high-throughput data. Before practically applying such pathway analysis (PA) methods, we must first evaluate their performance and reliability, using datasets where the pathways perturbed by the conditions of interest have been well characterized in advance. However, such 'ground truths' (or gold standards) are often unavailable. Furthermore, previous evaluation strategies that have focused on defining 'true answers' are unable to systematically and objectively assess PA methods under a wide range of conditions. In this work, we propose a novel strategy for evaluating PA methods independently of any gold standard, either established or assumed. The strategy involves the use of two mutually complementary metrics, recall and discrimination. Recall measures the consistency of the perturbed pathways identified by applying a particular analysis method to an original large dataset and those identified by the same method to a sub-dataset of the original dataset. In contrast, discrimination measures specificity-the degree to which the perturbed pathways identified by a particular method to a dataset from one experiment differ from those identifying by the same method to a dataset from a different experiment. We used these metrics and 24 datasets to evaluate six widely used PA methods. The results highlighted the common challenge in reliably identifying significant pathways from small datasets. Importantly, we confirmed the effectiveness of our proposed dual-metric strategy by showing that previous comparative studies corroborate the performance evaluations of the six methods obtained by our strategy. Unlike any previously proposed strategy for evaluating the performance of PA methods, our dual-metric strategy does not rely on any ground truth, either established or assumed, of the pathways perturbed by a specific clinical or experimental condition. As such, our strategy allows researchers to systematically and objectively evaluate pathway analysis methods by employing any number of datasets for a variety of conditions.
Perinetti, Giuseppe; Primozic, Jasmina; Sharma, Bhavna; Cioffi, Iacopo; Contardo, Luca
2018-03-28
The capability of the cervical vertebral maturation (CVM) method in the identification of the mandibular growth peak on an individual basis remains undetermined. The diagnostic reliability of the six-stage CVM method in the identification of the mandibular growth peak was thus investigated. From the files of the Oregon and Burlington Growth Studies (data obtained between early 1950s and middle 1970s), 50 subjects (26 females, 24 males) with at least seven annual lateral cephalograms taken from 9 to 16 years were identified. Cervical vertebral maturation was assessed according to the CVM code staging system, and mandibular growth was defined as annual increments in Co-Gn distance. A diagnostic reliability analysis was carried out to establish the capability of the circumpubertal CVM stages 2, 3, and 4 in the identification of the imminent mandibular growth peak. Variable durations of each of the CVM stages 2, 3, and 4 were seen. The overall diagnostic accuracy values for the CVM stages 2, 3, and 4 were 0.70, 0.76, and 0.77, respectively. These low values appeared to be due to false positive cases. Secular trends in conjunction with the use of a discrete staging system. In most of the Burlington Growth Study sample, the lateral head film at age 15 was missing. None of the CVM stages 2, 3, and 4 reached a satisfactorily diagnostic reliability in the identification of imminent mandibular growth peak.
Inspection planning development: An evolutionary approach using reliability engineering as a tool
NASA Technical Reports Server (NTRS)
Graf, David A.; Huang, Zhaofeng
1994-01-01
This paper proposes an evolutionary approach for inspection planning which introduces various reliability engineering tools into the process and assess system trade-offs among reliability, engineering requirement, manufacturing capability and inspection cost to establish an optimal inspection plan. The examples presented in the paper illustrate some advantages and benefits of the new approach. Through the analysis, reliability and engineering impacts due to manufacturing process capability and inspection uncertainty are clearly understood; the most cost effective and efficient inspection plan can be established and associated risks are well controlled; some inspection reductions and relaxations are well justified; and design feedbacks and changes may be initiated from the analysis conclusion to further enhance reliability and reduce cost. The approach is particularly promising as global competitions and customer quality improvement expectations are rapidly increasing.
Self-esteem among nursing assistants: reliability and validity of the Rosenberg Self-Esteem Scale.
McMullen, Tara; Resnick, Barbara
2013-01-01
To establish the reliability and validity of the Rosenberg Self-Esteem Scale (RSES) when used with nursing assistants (NAs). Testing the RSES used baseline data from a randomized controlled trial testing the Res-Care Intervention. Female NAs were recruited from nursing homes (n = 508). Validity testing for the positive and negative subscales of the RSES was based on confirmatory factor analysis (CFA) using structural equation modeling and Rasch analysis. Estimates of reliability were based on Rasch analysis and the person separation index. Evidence supports the reliability and validity of the RSES in NAs although we recommend minor revisions to the measure for subsequent use. Establishing reliable and valid measures of self-esteem in NAs will facilitate testing of interventions to strengthen workplace self-esteem, job satisfaction, and retention.
Ovarian and cervical cancer awareness: development of two validated measurement tools
Simon, Alice E; Wardle, Jane; Grimmett, Chloe; Power, Emily; Corker, Elizabeth; Menon, Usha; Matheson, Lauren; Waller, Jo
2012-01-01
Background The aim of the study was to develop and validate measures of awareness of symptoms and risk factors for ovarian and cervical cancer (Ovarian and Cervical Cancer Awareness Measures). Methods Potentially relevant items were extracted from the literature and generated by experts. Four validation studies were carried out to establish reliability and validity. Women aged 21–67 years (n=146) and ovarian and cervical cancer experts (n=32) were included in the studies. Internal reliability was assessed psychometrically. Test-retest reliability was assessed over a 1-week interval. To establish construct validity, Cancer Awareness Measure (CAM) scores of cancer experts were compared with equally well-educated comparison groups. Sensitivity to change was tested by randomly assigning participants to read either a leaflet giving information about ovarian/cervical cancer or a leaflet with control information, and then completing the ovarian/cervical CAM. Results Internal reliability (Cronbach's α=0.88 for the ovarian CAM and α=0.84 for the cervical CAM) and test-retest reliability (r=0.84 and r=0.77 for the ovarian and cervical CAMs, respectively) were both high. Validity was demonstrated with cancer experts achieving higher scores than controls [ovarian CAM: t(36)= –5.6, p<0.001; cervical CAM: t(38)= –3.7, p=0.001], and volunteers who were randomised to read a cancer leaflet scored higher than those who received a control leaflet [ovarian CAM: t(49)=7.5, p<0.001; cervical CAM: t(48)= –5.5, p<0.001]. Conclusions This study demonstrates the psychometric properties of the ovarian and cervical CAMs and supports their utility in assessing ovarian and cervical cancer awareness in the general population. PMID:21933805
Development of the caregivers attitude scale on home care of schizophrenics (CASHS)
Balasubramanian, N; Sathyanarayana Rao, T. S.; D’Sa, Juliana Linnette
2014-01-01
Background: Schizophrenia is a severe mental disorder that elicits feelings of strangeness and discomfort, which may create stigma and lead to the social exclusion of the mentally ill and of the people relating with them. In the past decade, there has been an increase in the number of research studies on attitudes toward mental disorders. Materials and Methods: An instrument was developed to assess the attitude of primary caregivers on home care of schizophrenics. This article describes the development of a Likert scale, the Caregivers Attitude Scale on Home Care of Schizophrenics CASHS, which is a 31-item self-reported instrument that quantifies three aspects of home care, that is, attitude towards patient, towards treatment, and towards social interaction. The steps involved in its development are the review of literature, development of items, content validation, translation and language validity, pretesting, and reliability. Results: After establishing the content validity, the CASHS was pretested with five subjects. To establish the reliability of the CASHS, 21 primary caregivers were recruited through purposive sampling technique. In order to measure the stability between scores obtained, a test-retest reliability was computed using Karl Pearson correlation coefficient and the r value was 0.78. The internal consistency was measured using Cronbach's alpha and item-total correlation and the r value was 0.789. The item discrimination analysis was also computed and the value was of above 0.35. These statistical measurements indicate that the CASHS was reliable. Conclusions: The CASHS is a valid and reliable tool that can be utilized for assessing the attitude of primary caregivers on home care of schizophrenics. PMID:24574561
2012-01-01
Background Adolescents and young adult (AYA) cancer survivors may have unique physical, psychological and social needs due to their cancer occurring at a critical phase of development. The aim of this study was to develop a psychometrically rigorous measure of unmet need to capture the specific needs of this group. Methods Items were developed following a comprehensive literature review, focus groups with AYAs, and feedback from health care providers, researchers and other professionals. The measure was pilot tested with 32 AYA cancer survivors recruited through a state-based cancer registry to establish face and content validity. A main sample of 139 AYA cancer patients and survivors were recruited through seven treatment centres and invited to complete the questionnaire. To establish test-retest reliability, a sub-sample of 34 participants completed the measure a second time. Exploratory factor analysis was performed and the measure was assessed for internal consistency, discriminative validity, potential responsiveness and acceptability. Results The Cancer Needs Questionnaire - Young People (CNQ-YP) has established face and content validity, and acceptability. The final measure has 70 items and six factors: Treatment Environment and Care (33 items); Feelings and Relationships (14 items); Daily Life (12 items); Information and Activities (5 items); Education (3 items); and Work (3 items). All domains achieved Cronbach's alpha values greater than 0.80. Item-to-item test-retest reliability was also high, with all but four items reaching weighted kappa values above 0.60. Conclusions The CNQ-YP is the first multi-dimensional measure of unmet need which has been developed specifically for AYA cancer patients and survivors. The measure displays a strong factor structure, and excellent internal consistency and test-retest reliability. However, the small sample size has implications for the reliability of the statistical analyses undertaken, particularly the exploratory factor analysis. Future studies with a larger sample are recommended to confirm the factor structure of the measure. Longitudinal studies to establish responsiveness and predictive validity should also be undertaken. PMID:22284545
On the Local Convergence of Pattern Search
NASA Technical Reports Server (NTRS)
Dolan, Elizabeth D.; Lewis, Robert Michael; Torczon, Virginia; Bushnell, Dennis M. (Technical Monitor)
2000-01-01
We examine the local convergence properties of pattern search methods, complementing the previously established global convergence properties for this class of algorithms. We show that the step-length control parameter which appears in the definition of pattern search algorithms provides a reliable asymptotic measure of first-order stationarity. This gives an analytical justification for a traditional stopping criterion for pattern search methods. Using this measure of first-order stationarity, we analyze the behavior of pattern search in the neighborhood of an isolated local minimizer. We show that a recognizable subsequence converges r-linearly to the minimizer.
ERIC Educational Resources Information Center
Beery, Thomas H.
2013-01-01
The purpose of this preliminary study is to establish a reliable and valid measure of environmental connectedness (EC) to allow for further exploration of the Swedish Outdoor Recreation in Change national survey data. The Nordic concept of friluftsliv (nature-based outdoor recreation) and the environmental psychology concept of EC are explored to…
Fernández, Ramón Fuentes; Carter, Pablo; Muñoz, Sergio; Silva, Héctor; Venegas, Gonzalo Hernán Oporto; Cantin, Mario; Ottone, Nicolás Ernesto
2016-01-01
INTRODUCTION Temporomandibular joint disorders (TMJDs) are caused by several factors such as anatomical, neuromuscular and psychological alterations. A relationship has been established between TMJDs and postural alterations, a type of anatomical alteration. An anterior position of the head requires hyperactivity of the posterior neck region and shoulder muscles to prevent the head from falling forward. This compensatory muscular function may cause fatigue, discomfort and trigger point activation. To our knowledge, a method for assessing human postural attitude in more than one plane has not been reported. Thus, the aim of this study was to design a methodology to measure the external human postural attitude in frontal and sagittal planes, with proper validity and reliability analyses. METHODS The variable postures of 78 subjects (36 men, 42 women; age 18–24 years) were evaluated. The postural attitudes of the subjects were measured in the frontal and sagittal planes, using an acromiopelvimeter, grid panel and Fox plane. RESULTS The method we designed for measuring postural attitudes had adequate reliability and validity, both qualitatively and quantitatively, based on Cohen’s Kappa coefficient (> 0.87) and Pearson’s correlation coefficient (r = 0.824, > 80%). CONCLUSION This method exhibits adequate metrical properties and can therefore be used in further research on the association of human body posture with skeletal types and TMJDs. PMID:26768173
Voehringer, Patrizia; Fuertig, René; Ferger, Boris
2013-11-15
Glycine is an important amino acid neurotransmitter in the central nervous system (CNS) and a useful biomarker to indicate biological activity of drugs such as glycine reuptake inhibitors (GRI) in the brain. Here, we report how a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the fast and reliable analysis of glycine in brain microdialysates and cerebrospinal fluid (CSF) samples has been established. Additionally, we compare this method with the conventional approach of high performance liquid chromatography (HPLC) coupled to fluorescence detection (FD). The present LC-MS/MS method did not require any derivatisation step. Fifteen microliters of sample were injected for analysis. Glycine was detected by a triple quadrupole mass spectrometer in the positive electrospray ionisation (ESI) mode. The total running time was 5min. The limit of quantitation (LOQ) was determined as 100nM, while linearity was given in the range from 100nM to 100μM. In order to demonstrate the feasibility of the LC-MS/MS method, we measured glycine levels in striatal in vivo microdialysates and CSF of rats after administration of the commercially available glycine transporter 1 (GlyT1) inhibitor LY 2365109 (10mg/kg, p.o.). LY 2365109 produced 2-fold and 3-fold elevated glycine concentrations from 1.52μM to 3.6μM in striatal microdialysates and from 10.38μM to 36μM in CSF, respectively. In conclusion, we established a fast and reliable LC-MS/MS method, which can be used for the quantification of glycine in brain microdialysis and CSF samples in biomarker studies. Copyright © 2013 Elsevier B.V. All rights reserved.
Han, Min; Kang, Xing; Liu, Zhengbin; Zhang, Tingting; Li, Yanwei; Chen, Chao; Wang, Huijuan
2017-07-01
HLA-B*57:01 is strongly associated with severe adverse drug reaction induced by the anti-HIV drug abacavir (ABC) and antibiotic flucloxacillin. This study was dedicated to establishing a new method for HLA-B*57:01 genotyping and investigating the HLA-B*57:01 distribution pattern in four Chinese populations. A single-tube duplex real-time polymerase chain reaction (PCR) system was established by combining the amplification refractory mutation system and TaqMan probe. The reliability of this assay was validated by comparing the genotyping results with those by sequence-based typing. With this assay, the distribution of HLA-B*57:01 in 354 blood samples from four ethnic groups, namely, Han, Tibetan, Uighur, and Buyei, was determined. A 100% concordance was observed between the results of real-time PCR and sequence-based typing in 50 Uighur samples. As low as 0.016 ng DNA that carried HLA-B*57:01 could be detected with this assay. HLA-B*57:01 carriers identified in 100 Northern Han Chinese, 104 Buyeis, 100 Tibetans, and 50 Uighurs were 0, 1 (0.96%), 3 (3%), and 6 (12%), respectively. The carrier rate of HLA-B*57:01 in Uighur was significantly higher than those in Northern Han (p = .001) and Buyei (p = .005). The newly established real-time PCR assay provides a rapid and reliable tool for HLA-B*57:01 allele screening before the prescription of ABC and flucloxacillin in clinical practice.
Yousuf, Naveed; Violato, Claudio; Zuberi, Rukhsana W
2015-01-01
CONSTRUCT: Authentic standard setting methods will demonstrate high convergent validity evidence of their outcomes, that is, cutoff scores and pass/fail decisions, with most other methods when compared with each other. The objective structured clinical examination (OSCE) was established for valid, reliable, and objective assessment of clinical skills in health professions education. Various standard setting methods have been proposed to identify objective, reliable, and valid cutoff scores on OSCEs. These methods may identify different cutoff scores for the same examinations. Identification of valid and reliable cutoff scores for OSCEs remains an important issue and a challenge. Thirty OSCE stations administered at least twice in the years 2010-2012 to 393 medical students in Years 2 and 3 at Aga Khan University are included. Psychometric properties of the scores are determined. Cutoff scores and pass/fail decisions of Wijnen, Cohen, Mean-1.5SD, Mean-1SD, Angoff, borderline group and borderline regression (BL-R) methods are compared with each other and with three variants of cluster analysis using repeated measures analysis of variance and Cohen's kappa. The mean psychometric indices on the 30 OSCE stations are reliability coefficient = 0.76 (SD = 0.12); standard error of measurement = 5.66 (SD = 1.38); coefficient of determination = 0.47 (SD = 0.19), and intergrade discrimination = 7.19 (SD = 1.89). BL-R and Wijnen methods show the highest convergent validity evidence among other methods on the defined criteria. Angoff and Mean-1.5SD demonstrated least convergent validity evidence. The three cluster variants showed substantial convergent validity with borderline methods. Although there was a high level of convergent validity of Wijnen method, it lacks the theoretical strength to be used for competency-based assessments. The BL-R method is found to show the highest convergent validity evidences for OSCEs with other standard setting methods used in the present study. We also found that cluster analysis using mean method can be used for quality assurance of borderline methods. These findings should be further confirmed by studies in other settings.
1994-06-30
tip Opening Displacement (CTOD) Fracture Toughness Measurement". 48 The method has found application in the elastic-plastic fracture mechanics ( EPFM ...68 6.1 Proposed Material Property Database Format and Hierarchy .............. 68 6.2 Sample Application of the Material Property Database...the E 49.05 sub-committee. The relevant quality indicators applicable to the present program are: source of data, statistical basis of data
Oviedo-Caro, Miguel Ángel; Bueno-Antequera, Javier; Munguía-Izquierdo, Diego
2018-03-19
To transculturally adapt the Spanish version of Pregnancy Physical Activity Questionnaire (PPAQ) analyzing its psychometric properties. The PPAQ was transculturally adapted into Spanish. Test-retest reliability was evaluated in a subsample of 109 pregnant women. The validity was evaluated in a sample of 208 pregnant women who answered the questionnaire and wore the multi-sensor monitor for 7 valid days. The reliability (intraclass correlation coefficient), concordance (concordance correlation coefficient), correlation (Pearson correlation coefficient), agreement (Bland-Altman plots) and relative activity levels (Jonckheere-Terpstra test) between both administrations and methods were examined. Intraclass correlation coefficients between both administrations were good for all categories except transportation. A low but significant correlation was found for total activity (light and above) whereas no correlation was found for other intensities between both methods. Relative activity levels analysis showed a significant linear trend for increased total activity between both methods. Spanish version of PPAQ is a brief and easily interpretable questionnaire with good reliability and ability to rank individuals, and poor validity compared with multi-sensor monitor. The use of PPAQ provides information of pregnancy-specific activities in order to establish physical activity levels of pregnant women and adapt health promotion interventions. Copyright © 2018 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.
Establishment of a method for determination of arsenic species in seafood by LC-ICP-MS.
Zmozinski, Ariane V; Llorente-Mirandes, Toni; López-Sánchez, José F; da Silva, Márcia M
2015-04-15
An analytical method for determination of arsenic species (inorganic arsenic (iAs), methylarsonic acid (MA), dimethylarsinic acid (DMA), arsenobetaine (AB), trimethylarsine oxide (TMAO) and arsenocholine (AC)) in Brazilian and Spanish seafood samples is reported. This study was focused on extraction and quantification of inorganic arsenic (iAs), the most toxic form. Arsenic speciation was carried out via LC with both anionic and cationic exchange with ICP-MS detection (LC-ICP-MS). The detection limits (LODs), quantification limits (LOQs), precision and accuracy for arsenic species were established. The proposed method was evaluated using eight reference materials (RMs). Arsenobetaine was the main species found in all samples. The total and iAs concentration in 22 seafood samples and RMs ranged between 0.27-35.2 and 0.02-0.71 mg As kg(-1), respectively. Recoveries ranging from 100% to 106% for iAs, based on spikes, were achieved. The proposed method provides reliable iAs data for future risk assessment analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.
Nonlinear Rayleigh wave inversion based on the shuffled frog-leaping algorithm
NASA Astrophysics Data System (ADS)
Sun, Cheng-Yu; Wang, Yan-Yan; Wu, Dun-Shi; Qin, Xiao-Jun
2017-12-01
At present, near-surface shear wave velocities are mainly calculated through Rayleigh wave dispersion-curve inversions in engineering surface investigations, but the required calculations pose a highly nonlinear global optimization problem. In order to alleviate the risk of falling into a local optimal solution, this paper introduces a new global optimization method, the shuffle frog-leaping algorithm (SFLA), into the Rayleigh wave dispersion-curve inversion process. SFLA is a swarm-intelligence-based algorithm that simulates a group of frogs searching for food. It uses a few parameters, achieves rapid convergence, and is capability of effective global searching. In order to test the reliability and calculation performance of SFLA, noise-free and noisy synthetic datasets were inverted. We conducted a comparative analysis with other established algorithms using the noise-free dataset, and then tested the ability of SFLA to cope with data noise. Finally, we inverted a real-world example to examine the applicability of SFLA. Results from both synthetic and field data demonstrated the effectiveness of SFLA in the interpretation of Rayleigh wave dispersion curves. We found that SFLA is superior to the established methods in terms of both reliability and computational efficiency, so it offers great potential to improve our ability to solve geophysical inversion problems.
A novel interacting multiple model based network intrusion detection scheme
NASA Astrophysics Data System (ADS)
Xin, Ruichi; Venkatasubramanian, Vijay; Leung, Henry
2006-04-01
In today's information age, information and network security are of primary importance to any organization. Network intrusion is a serious threat to security of computers and data networks. In internet protocol (IP) based network, intrusions originate in different kinds of packets/messages contained in the open system interconnection (OSI) layer 3 or higher layers. Network intrusion detection and prevention systems observe the layer 3 packets (or layer 4 to 7 messages) to screen for intrusions and security threats. Signature based methods use a pre-existing database that document intrusion patterns as perceived in the layer 3 to 7 protocol traffics and match the incoming traffic for potential intrusion attacks. Alternately, network traffic data can be modeled and any huge anomaly from the established traffic pattern can be detected as network intrusion. The latter method, also known as anomaly based detection is gaining popularity for its versatility in learning new patterns and discovering new attacks. It is apparent that for a reliable performance, an accurate model of the network data needs to be established. In this paper, we illustrate using collected data that network traffic is seldom stationary. We propose the use of multiple models to accurately represent the traffic data. The improvement in reliability of the proposed model is verified by measuring the detection and false alarm rates on several datasets.
Tessonnière, H; Vidal, S; Barnavon, L; Alexandre, H; Remize, F
2009-02-28
Because the yeast Brettanomyces produces volatile phenols and acetic acid, it is responsible for wine spoilage. The uncontrolled accumulation of these molecules in wine leads to sensorial defects that compromise wine quality. The need for a rapid, specific, sensitive and reliable method to detect this spoilage yeast has increased over the last decade. All these requirements are met by real-time PCR. We here propose improvements of existing methods to enhance the robustness of the assay. Six different protocols to isolate DNA from a wine and three PCR mix compositions were tested, and the best method was selected. Insoluble PVPP addition during DNA extraction by a classical phenol:chloroform protocol succeeded in the relief of PCR inhibitors from wine. We developed an internal control which was efficient to avoid false negative results due to decreases in the efficiency of DNA isolation and/or amplification. The method was evaluated by an intra-laboratory study for its specificity, linearity, repeatability and reproducibility. A standard curve was established from 14 different wines artificially inoculated. The quantification limit was 31 cfu/mL.
A new semiquantitative method for evaluation of metastasis progression.
Volarevic, A; Ljujic, B; Volarevic, V; Milovanovic, M; Kanjevac, T; Lukic, A; Arsenijevic, N
2012-01-01
Although recent technical advancements are directed toward developing novel assays and methods for detection of micro and macro metastasis, there are still no reports of reliable, simple to use imaging software that could be used for the detection and quantification of metastasis in tissue sections. We herein report a new semiquantitative method for evaluation of metastasis progression in a well established 4T1 orthotopic mouse model of breast cancer metastasis. The new semiquantitative method presented here was implemented by using the Autodesk AutoCAD 2012 program, a computer-aided design program used primarily for preparing technical drawings in 2 dimensions. By using the Autodesk AutoCAD 2012 software- aided graphical evaluation we managed to detect each metastatic lesion and we precisely calculated the average percentage of lung and liver tissue parenchyma with metastasis in 4T1 tumor-bearing mice. The data were highly specific and relevant to descriptive histological analysis, confirming reliability and accuracy of the AutoCAD 2012 software as new method for quantification of metastatic lesions. The new semiquantitative method using AutoCAD 2012 software provides a novel approach for the estimation of metastatic progression in histological tissue sections.
NASA Technical Reports Server (NTRS)
Jacklin, Stephen; Schumann, Johann; Gupta, Pramod; Richard, Michael; Guenther, Kurt; Soares, Fola
2005-01-01
Adaptive control technologies that incorporate learning algorithms have been proposed to enable automatic flight control and vehicle recovery, autonomous flight, and to maintain vehicle performance in the face of unknown, changing, or poorly defined operating environments. In order for adaptive control systems to be used in safety-critical aerospace applications, they must be proven to be highly safe and reliable. Rigorous methods for adaptive software verification and validation must be developed to ensure that control system software failures will not occur. Of central importance in this regard is the need to establish reliable methods that guarantee convergent learning, rapid convergence (learning) rate, and algorithm stability. This paper presents the major problems of adaptive control systems that use learning to improve performance. The paper then presents the major procedures and tools presently developed or currently being developed to enable the verification, validation, and ultimate certification of these adaptive control systems. These technologies include the application of automated program analysis methods, techniques to improve the learning process, analytical methods to verify stability, methods to automatically synthesize code, simulation and test methods, and tools to provide on-line software assurance.
Bime, Christian; Wei, Christine Y.; Holbrook, Janet T.; Sockrider, Marianna M.; Revicki, Dennis A.; Wise, Robert A.
2012-01-01
Background The evaluation of asthma symptoms is a core outcome measure in asthma clinical research. The Asthma Symptom Utility Index (ASUI) was developed to assess frequency and severity of asthma symptoms. The psychometric properties of the ASUI are not well characterized and a minimal important difference (MID) is not established. Objectives We assessed the reliability, validity, and responsiveness to change of the ASUI in a population of adult asthma patients. We also sought to determine the MID for the ASUI. Methods Adult asthma patients (n = 1648) from two previously completed multicenter randomized trials were included. Demographic information, spirometry, ASUI scores, and other asthma questionnaire scores were obtained at baseline and during follow-up visits. Participants also kept a daily asthma diary. Results Internal consistency reliability of the ASUI was 0.74 (Cronbach’s alpha). Test-retest reliability was 0.76 (intra-class correlation). Construct validity was demonstrated by significant correlations between ASUI scores and Asthma Control Questionnaire (ACQ) scores (Spearman correlation r = −0.79, 95% CI [−0.85, −0.75], P<0.001) and Mini Asthma Quality of Life Questionnaire (Mini AQLQ) scores (r = 0.59, 95% CI [0.51, 0.61], P<0.001). Responsiveness to change was demonstrated, with significant differences between mean changes in ASUI score across groups of participants differing by 10% in the percent predicted FEV1 (P<0.001), and by 0.5 points in ACQ score (P < 0.001). Anchor-based methods and statistical methods support an MID for the ASUI of 0.09 points. Conclusions The ASUI is reliable, valid, and responsive to changes in asthma control over time. The MID of the ASUI (range of scores 0–1) is 0.09. PMID:23026499
NASA Astrophysics Data System (ADS)
Sil, Arjun; Longmailai, Thaihamdau
2017-09-01
The lateral displacement of Reinforced Concrete (RC) frame building during an earthquake has an important impact on the structural stability and integrity. However, seismic analysis and design of RC building needs more concern due to its complex behavior as the performance of the structure links to the features of the system having many influencing parameters and other inherent uncertainties. The reliability approach takes into account the factors and uncertainty in design influencing the performance or response of the structure in which the safety level or the probability of failure could be ascertained. This present study, aims to assess the reliability of seismic performance of a four storey residential RC building seismically located in Zone-V as per the code provisions given in the Indian Standards IS: 1893-2002. The reliability assessment performed by deriving an explicit expression for maximum roof-lateral displacement as a failure function by regression method. A total of 319, four storey RC buildings were analyzed by linear static method using SAP2000. However, the change in the lateral-roof displacement with the variation of the parameters (column dimension, beam dimension, grade of concrete, floor height and total weight of the structure) was observed. A generalized relation established by regression method which could be used to estimate the expected lateral displacement owing to those selected parameters. A comparison made between the displacements obtained from analysis with that of the equation so formed. However, it shows that the proposed relation could be used directly to determine the expected maximum lateral displacement. The data obtained from the statistical computations was then used to obtain the probability of failure and the reliability.
Establishing the reliability of rhesus macaque social network assessment from video observations
Feczko, Eric; Mitchell, Thomas A. J.; Walum, Hasse; Brooks, Jenna M.; Heitz, Thomas R.; Young, Larry J.; Parr, Lisa A.
2015-01-01
Understanding the properties of a social environment is important for understanding the dynamics of social relationships. Understanding such dynamics is relevant for multiple fields, ranging from animal behaviour to social and cognitive neuroscience. To quantify social environment properties, recent studies have incorporated social network analysis. Social network analysis quantifies both the global and local properties of a social environment, such as social network efficiency and the roles played by specific individuals, respectively. Despite the plethora of studies incorporating social network analysis, methods to determine the amount of data necessary to derive reliable social networks are still being developed. Determining the amount of data necessary for a reliable network is critical for measuring changes in the social environment, for example following an experimental manipulation, and therefore may be critical for using social network analysis to statistically assess social behaviour. In this paper, we extend methods for measuring error in acquired data and for determining the amount of data necessary to generate reliable social networks. We derived social networks from a group of 10 male rhesus macaques, Macaca mulatta, for three behaviours: spatial proximity, grooming and mounting. Behaviours were coded using a video observation technique, where video cameras recorded the compound where the 10 macaques resided. We collected, coded and used 10 h of video data to construct these networks. Using the methods described here, we found in our data that 1 h of spatial proximity observations produced reliable social networks. However, this may not be true for other studies due to differences in data acquisition. Our results have broad implications for measuring and predicting the amount of error in any social network, regardless of species. PMID:26392632
18 CFR 292.308 - Standards for operating reliability.
Code of Federal Regulations, 2010 CFR
2010-04-01
... reliability. 292.308 Section 292.308 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... SMALL POWER PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying... may establish reasonable standards to ensure system safety and reliability of interconnected...
Stanifer, John W.; Karia, Francis; Voils, Corrine I.; Turner, Elizabeth L.; Maro, Venance; Shimbi, Dionis; Kilawe, Humphrey; Lazaro, Matayo; Patel, Uptal D.
2015-01-01
Introduction Non-communicable diseases are a growing global burden, and structured surveys can identify critical gaps to address this epidemic. In sub-Saharan Africa, there are very few well-tested survey instruments measuring population attributes related to non-communicable diseases. To meet this need, we have developed and validated the first instrument evaluating knowledge, attitudes and practices pertaining to chronic kidney disease in a Swahili-speaking population. Methods and Results Between December 2013 and June 2014, we conducted a four-stage, mixed-methods study among adults from the general population of northern Tanzania. In stage 1, the survey instrument was constructed in English by a group of cross-cultural experts from multiple disciplines and through content analysis of focus group discussions to ensure local significance. Following translation, in stage 2, we piloted the survey through cognitive and structured interviews, and in stage 3, in order to obtain initial evidence of reliability and construct validity, we recruited and then administered the instrument to a random sample of 606 adults. In stage 4, we conducted analyses to establish test-retest reliability and known-groups validity which was informed by thematic analysis of the qualitative data in stages 1 and 2. The final version consisted of 25 items divided into three conceptual domains: knowledge, attitudes and practices. Each item demonstrated excellent test-retest reliability with established content and construct validity. Conclusions We have developed a reliable and valid cross-cultural survey instrument designed to measure knowledge, attitudes and practices of chronic kidney disease in a Swahili-speaking population of Northern Tanzania. This instrument may be valuable for addressing gaps in non-communicable diseases care by understanding preferences regarding healthcare, formulating educational initiatives, and directing development of chronic disease management programs that incorporate chronic kidney disease across sub-Saharan Africa. PMID:25811781
A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press.
Rahmani, Abderrahmane; Samozino, Pierre; Morin, Jean-Benoit; Morel, Baptiste
2018-02-01
To analyze the reliability and validity of a field computation method based on easy-to-measure data to assess the mean force ([Formula: see text]) and velocity ([Formula: see text]) produced during a ballistic bench-press movement and to verify that the force-velocity profile (F-v) obtained with multiple loaded trials is accurately described. Twelve participants performed ballistic bench presses against various lifted mass from 30% to 70% of their body mass. For each trial, [Formula: see text] and [Formula: see text] were determined from an accelerometer (sampling rate 500 Hz; reference method) and a simple computation method based on upper-limb mass, barbell flight height, and push-off distance. These [Formula: see text] and [Formula: see text] data were used to establish the F-v relationship for each individual and method. A strong to almost perfect reliability was observed between the 2 trials (ICC > .90 for [Formula: see text] and .80 for [Formula: see text], CV% < 10%), whatever the considered method. The mechanical variables ([Formula: see text], [Formula: see text]) measured with the 2 methods and all the variables extrapolated from the F-v relationships were strongly correlated (r 2 > .80, P < .001). The practical differences between the methods for the extrapolated mechanical parameters were all <5%, indicating very probably no differences. The findings suggest that the simple computation method used here provides valid and reliable information on force and velocity produced during ballistic bench press, in line with that observed in laboratory conditions. This simple method is thus a practical tool, requiring only 3 simple parameters (upper-limb mass, barbell flight height, and push-off distance).
Hosseini, Mohammad-Parsa; Nazem-Zadeh, Mohammad-Reza; Pompili, Dario; Jafari-Khouzani, Kourosh; Elisevich, Kost; Soltanian-Zadeh, Hamid
2016-01-01
Purpose: Segmentation of the hippocampus from magnetic resonance (MR) images is a key task in the evaluation of mesial temporal lobe epilepsy (mTLE) patients. Several automated algorithms have been proposed although manual segmentation remains the benchmark. Choosing a reliable algorithm is problematic since structural definition pertaining to multiple edges, missing and fuzzy boundaries, and shape changes varies among mTLE subjects. Lack of statistical references and guidance for quantifying the reliability and reproducibility of automated techniques has further detracted from automated approaches. The purpose of this study was to develop a systematic and statistical approach using a large dataset for the evaluation of automated methods and establish a method that would achieve results better approximating those attained by manual tracing in the epileptogenic hippocampus. Methods: A template database of 195 (81 males, 114 females; age range 32–67 yr, mean 49.16 yr) MR images of mTLE patients was used in this study. Hippocampal segmentation was accomplished manually and by two well-known tools (FreeSurfer and hammer) and two previously published methods developed at their institution [Automatic brain structure segmentation (ABSS) and LocalInfo]. To establish which method was better performing for mTLE cases, several voxel-based, distance-based, and volume-based performance metrics were considered. Statistical validations of the results using automated techniques were compared with the results of benchmark manual segmentation. Extracted metrics were analyzed to find the method that provided a more similar result relative to the benchmark. Results: Among the four automated methods, ABSS generated the most accurate results. For this method, the Dice coefficient was 5.13%, 14.10%, and 16.67% higher, Hausdorff was 22.65%, 86.73%, and 69.58% lower, precision was 4.94%, −4.94%, and 12.35% higher, and the root mean square (RMS) was 19.05%, 61.90%, and 65.08% lower than LocalInfo, FreeSurfer, and hammer, respectively. The Bland–Altman similarity analysis revealed a low bias for the ABSS and LocalInfo techniques compared to the others. Conclusions: The ABSS method for automated hippocampal segmentation outperformed other methods, best approximating what could be achieved by manual tracing. This study also shows that four categories of input data can cause automated segmentation methods to fail. They include incomplete studies, artifact, low signal-to-noise ratio, and inhomogeneity. Different scanner platforms and pulse sequences were considered as means by which to improve reliability of the automated methods. Other modifications were specially devised to enhance a particular method assessed in this study. PMID:26745947
Mohammed, Rezwana Begum; Kalyan, V Siva; Tircouveluri, Saritha; Vegesna, Goutham Chakravarthy; Chirla, Anil; Varma, D Maruthi
2014-07-01
Determining the age of a person in the absence of documentary evidence of birth is essential for legal and medico-legal purpose. Fishman method of skeletal maturation is widely used for this purpose; however, the reliability of this method for people with all geographic locations is not well-established. In this study, we assessed various stages of carpal and metacarpal bone maturation and tested the reliability of Fishman method of skeletal maturation to estimate the age in South Indian population. We also evaluated the correlation between the chronological age (CA) and predicted age based on the Fishman method of skeletal maturation. Digital right hand-wrist radiographs of 330 individuals aged 9-20 years were obtained and the skeletal maturity stage for each subject was determined using Fishman method. The skeletal maturation indicator scores were obtained and analyzed with reference to CA and sex. Data was analyzed using the SPSS software package (version 12, SPSS Inc., Chicago, IL, USA). The study subjects had a tendency toward late maturation with the mean skeletal age (SA) estimated being significantly lowers (P < 0.05) than the mean CA at various skeletal maturity stages. Nevertheless, significant correlation was observed in this study between SA and CA for males (r = 0.82) and females (r = 0.85). Interestingly, female subjects were observed to be advanced in SA compared with males. Fishman method of skeletal maturation can be used as an alternative tool for the assessment of mean age of an individual of unknown CA in South Indian children.
Lo, Wing-Sze; Ho, Sai-Yin; Wong, Bonny Yee-Man; Mak, Kwok-Kei; Lam, Tai-Hing
2011-06-01
The reliability and validity of Stunkard's Figure Rating Scale (FRS) as a measure of current body size (CBS) was established in Western adolescent girls but not in non-Western population. We examined the validity and test-retest reliability of Stunkard's FRS in assessing CBS among Chinese adolescents. Methods. In a school-based survey in Hong Kong, 5666 adolescents (boys: 45.1%; mean age 14.7 years) provided data on self-reported height and weight, CBS, perceived weight status, and health-related quality of life using the Medical Outcomes Study Short-Form version 2 (SF-12v2). Height and weight were also objectively measured. Spearman's correlation was used to assess construct validity, concurrent validity and test-retest reliability. Convergent and discriminant validity were good: CBS correlated strongly with weight and self-reported/measured BMI, but only weakly with SF-12v2. CBS correlated strongly with perceived weight status, showing concurrent validity. Spearman's correlation (r) for CBS was 0.78 for girls and 0.72 for boys indicating good test-retest reliability. Validity and reliability results did not differ significantly between senior and junior grade adolescents. Our findings support the use of Stunkard's FRS to measure body size among Chinese adolescents.
Best Practices for Reliable and Robust Spacecraft Structures
NASA Technical Reports Server (NTRS)
Raju, Ivatury S.; Murthy, P. L. N.; Patel, Naresh R.; Bonacuse, Peter J.; Elliott, Kenny B.; Gordon, S. A.; Gyekenyesi, J. P.; Daso, E. O.; Aggarwal, P.; Tillman, R. F.
2007-01-01
A study was undertaken to capture the best practices for the development of reliable and robust spacecraft structures for NASA s next generation cargo and crewed launch vehicles. In this study, the NASA heritage programs such as Mercury, Gemini, Apollo, and the Space Shuttle program were examined. A series of lessons learned during the NASA and DoD heritage programs are captured. The processes that "make the right structural system" are examined along with the processes to "make the structural system right". The impact of technology advancements in materials and analysis and testing methods on reliability and robustness of spacecraft structures is studied. The best practices and lessons learned are extracted from these studies. Since the first human space flight, the best practices for reliable and robust spacecraft structures appear to be well established, understood, and articulated by each generation of designers and engineers. However, these best practices apparently have not always been followed. When the best practices are ignored or short cuts are taken, risks accumulate, and reliability suffers. Thus program managers need to be vigilant of circumstances and situations that tend to violate best practices. Adherence to the best practices may help develop spacecraft systems with high reliability and robustness against certain anomalies and unforeseen events.
Miller, M; Hamilton, J; Scupham, R; Matwiejczyk, L; Prichard, I; Farrer, O; Yaxley, A
2018-01-01
Food service staff are integral to delivery of quality food in aged care homes yet measurement of their satisfaction is unable to be performed due to an absence of a valid and reliable questionnaire. The aim of this study was to develop and perform psychometric testing for a new Food Service Satisfaction Questionnaire developed in Australia specifically for use by food service staff working in residential aged care homes (Flinders FSSQFSAC). A mixed methods design utilizing both a qualitative (in-depth interviews, focus groups) and a quantitative approach (cross sectional survey) was used. Content validity was determined from focus groups and interviews with food service staff currently working in aged care homes, related questionnaires from the literature and consultation with an expert panel. The questionnaire was tested for construct validity and internal consistency using data from food service staff currently working in aged care homes that responded to an electronic invitation circulated to Australian aged care homes using a national database of email addresses. Construct validity was tested via principle components analysis and internal consistency through Cronbach's alpha. Temporal stability of the questionnaire was determined from food service staff undertaking the Flinders FSSQFSAC on two occasions, two weeks apart, and analysed using Pearson's correlations. Content validity for the Flinders FSSQFSAC was established from a panel of experts and stakeholders. Principle components analysis revealed food service staff satisfaction was represented by 61-items divided into eight domains: job satisfaction (α=0.832), food quality (α=0.871), staff training (α=0.922), consultation (α=0.840), eating environment (α=0.777), reliability (α=0.695), family expectations (α=0.781) and resident relationships (α=0.429), establishing construct validity in all domains, and internal consistency in all (α>0.5) except for "resident relationships" (α=0.429). Test-retest reliability coefficients ranged from 0.276 to 0.826 dependent on domain, with test-retest reliability established in seven domains at r>0.4; an exception was "reliability" at r=0.276. The newly developed Flinders FSSQFSAC has acceptable validity and reliability and thereby the potential to measure satisfaction of food service staff working in residential aged care homes, identify areas for strategic change, measure improvements and in turn, improve the satisfaction and quality of life of both food service staff and residents of aged care homes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skees, J. Daniel
2010-06-15
The Energy Policy Act of 2005 established mandatory reliability standard enforcement under a system in which the Federal Energy Regulatory Commission and the Electric Reliability Organization would have their own spheres of responsibility and authority. Recent orders, however, reflect the Commission's frustration with the reliability standard drafting process and suggest that the Electric Reliability Organization's discretion is likely to receive less deference in the future. (author)
Chen, Wei; Zeng, Guang
2006-02-01
To establish a comprehensive assessment model on the ability of emergency response within the public health system in flooding-prone areas. A hierarchy process theory was used to establish the initial assessing framework. Delphi method was used to screen and choose the ultimate indicators and their weights before an assessment model was set up under the 'synthetic scored method' to assess the ability of the emergency response among twenty county public health units. We then used the 'analysis of variation (ANOVA)' methodology to test the feasibility of distinguishing the ability of emergency response among different county health units and correlation analysis was used to assess the independence of indicators in the assessing model. A comprehensive model was then established including twenty first-class indicators and fifty-six second-class indicators and the degree of ability to emergency response with flooding of public health units was evaluated. There were five public health units having higher, ten having moderate but five with lower levels on emergency response. The assessment model was proved to be a good method in differentiating the ability of public health units, using independent indicators. The assessment model which we established seemed to be practical and reliable.
Peleg, Smadar; Dar, Gali; Steinberg, Nili; Peled, Nathan; Hershkovitz, Israel; Masharawi, Youssef
2007-07-01
A descriptive study of the sacral anatomic orientation (SAO) and its association with pelvic incidence (PI). To introduce the concept of SAO, establish a method for measuring it, and evaluate its association with pelvic orientation. Pelvic orientation (PO) is considered a key factor in spinal shape and balance. Sacral slope (SS), PI, and pelvic tilt (PT) are the most frequently used parameters for evaluating PO. Nevertheless, the association between the anatomic orientation of the sacrum and these parameters has never been established. The aim of the present study is to define the anatomic orientation of the sacrum, to establish a reliable method for measuring it, and to examine its association with PI. SAO was defined as the angle created between the intersection of a line running parallel to the superior endplate surface of the sacrum and a line running between the anterior superior iliac spine (ASIS) and the anterior-superior edge of the symphysis pubis. Methods for measuring SAO and PI on both skeletal populations and living individuals are described. The study was carried out on 424 skeletons (articulated pelves) using a three-dimensional digitizer and on 20 adult individuals using CT three-dimensional images (volume-rendering method). Reliability (intratester and intertester) was assessed using intraclass correlation test. A regression analysis was carried out to evaluate the association between the two measurements. The mean SAO and PI in the human skeletal population were found to be 48.46 degrees +/- 10.17 degrees and 54.08 degrees +/- 12.64 degrees , respectively and of the living individuals (CT) 52.76 degrees +/- 10.31 degrees and 57.14 degrees +/- 13.08 degrees , respectively. SAO and PI measurements were highly correlated (r = -0.824, and r = -0.828, P < 0.001 for skeletal material and living individuals, respectively). PI can be predicted via SAO, i.e., PI = [-0.971 x SAO] + 101.16 degrees . The newly suggested parameter (SAO) may be an important tool in defining the sagittal shape of the spine and understanding its association with spinal diseases.
Fixture tests bellows reliability through repetitive pressure/temperature cycling
NASA Technical Reports Server (NTRS)
Levinson, C.
1967-01-01
Fixture explores the reliability of bellows used in precision in inertial systems. The fixture establishes the ability of the bellows to withstand repetitive over-stress pressure cycling at elevated temperatures. It is applicable in quality control and reliability programs.
18 CFR 39.8 - Delegation to a Regional Entity.
Code of Federal Regulations, 2010 CFR
2010-04-01
... agreement promotes effective and efficient administration of Bulk-Power System reliability. (d) The... Interconnection-wide basis promotes effective and efficient administration of Bulk-Power System reliability and... THE ELECTRIC RELIABILITY ORGANIZATION; AND PROCEDURES FOR THE ESTABLISHMENT, APPROVAL, AND ENFORCEMENT...
Tan, Christine L.; Hassali, Mohamed A.; Saleem, Fahad; Shafie, Asrul A.; Aljadhey, Hisham; Gan, Vincent B.
2015-01-01
Objective: (i) To develop the Pharmacy Value-Added Services Questionnaire (PVASQ) using emerging themes generated from interviews. (ii) To establish reliability and validity of questionnaire instrument. Methods: Using an extended Theory of Planned Behavior as the theoretical model, face-to-face interviews generated salient beliefs of pharmacy value-added services. The PVASQ was constructed initially in English incorporating important themes and later translated into the Malay language with forward and backward translation. Intention (INT) to adopt pharmacy value-added services is predicted by attitudes (ATT), subjective norms (SN), perceived behavioral control (PBC), knowledge and expectations. Using a 7-point Likert-type scale and a dichotomous scale, test-retest reliability (N=25) was assessed by administrating the questionnaire instrument twice at an interval of one week apart. Internal consistency was measured by Cronbach’s alpha and construct validity between two administrations was assessed using the kappa statistic and the intraclass correlation coefficient (ICC). Confirmatory Factor Analysis, CFA (N=410) was conducted to assess construct validity of the PVASQ. Results: The kappa coefficients indicate a moderate to almost perfect strength of agreement between test and retest. The ICC for all scales tested for intra-rater (test-retest) reliability was good. The overall Cronbach’ s alpha (N=25) is 0.912 and 0.908 for the two time points. The result of CFA (N=410) showed most items loaded strongly and correctly into corresponding factors. Only one item was eliminated. Conclusions: This study is the first to develop and establish the reliability and validity of the Pharmacy Value-Added Services Questionnaire instrument using the Theory of Planned Behavior as the theoretical model. The translated Malay language version of PVASQ is reliable and valid to predict Malaysian patients’ intention to adopt pharmacy value-added services to collect partial medicine supply. PMID:26445622
Advancing implementation science through measure development and evaluation: a study protocol.
Lewis, Cara C; Weiner, Bryan J; Stanick, Cameo; Fischer, Sarah M
2015-07-22
Significant gaps related to measurement issues are among the most critical barriers to advancing implementation science. Three issues motivated the study aims: (a) the lack of stakeholder involvement in defining pragmatic measure qualities; (b) the dearth of measures, particularly for implementation outcomes; and (c) unknown psychometric and pragmatic strength of existing measures. Aim 1: Establish a stakeholder-driven operationalization of pragmatic measures and develop reliable, valid rating criteria for assessing the construct. Aim 2: Develop reliable, valid, and pragmatic measures of three critical implementation outcomes, acceptability, appropriateness, and feasibility. Aim 3: Identify Consolidated Framework for Implementation Research and Implementation Outcome Framework-linked measures that demonstrate both psychometric and pragmatic strength. For Aim 1, we will conduct (a) interviews with stakeholder panelists (N = 7) and complete a literature review to populate pragmatic measure construct criteria, (b) Q-sort activities (N = 20) to clarify the internal structure of the definition, (c) Delphi activities (N = 20) to achieve consensus on the dimension priorities, (d) test-retest and inter-rater reliability assessments of the emergent rating system, and (e) known-groups validity testing of the top three prioritized pragmatic criteria. For Aim 2, our systematic development process involves domain delineation, item generation, substantive validity assessment, structural validity assessment, reliability assessment, and predictive validity assessment. We will also assess discriminant validity, known-groups validity, structural invariance, sensitivity to change, and other pragmatic features. For Aim 3, we will refine our established evidence-based assessment (EBA) criteria, extract the relevant data from the literature, rate each measure using the EBA criteria, and summarize the data. The study outputs of each aim are expected to have a positive impact as they will establish and guide a comprehensive measurement-focused research agenda for implementation science and provide empirically supported measures, tools, and methods for accomplishing this work.
de Vries, Merlijn W; Visscher, Corine; Delwel, Suzanne; van der Steen, Jenny T; Pieper, Marjoleine J C; Scherder, Erik J A; Achterberg, Wilco P; Lobbezoo, Frank
2016-01-01
Objectives. The aim of this study was to establish the reliability of the "chewing" subscale of the OPS-NVI, a novel tool designed to estimate presence and severity of orofacial pain in nonverbal patients. Methods. The OPS-NVI consists of 16 items for observed behavior, classified into four categories and a subjective estimate of pain. Two observers used the OPS-NVI for 237 video clips of people with dementia in Dutch nursing homes during their meal to observe their behavior and to estimate the intensity of orofacial pain. Six weeks later, the same observers rated the video clips a second time. Results. Bottom and ceiling effects for some items were found. This resulted in exclusion of these items from the statistical analyses. The categories which included the remaining items (n = 6) showed reliability varying between fair-to-good and excellent (interobserver reliability, ICC: 0.40-0.47; intraobserver reliability, ICC: 0.40-0.92). Conclusions. The "chewing" subscale of the OPS-NVI showed a fair-to-good to excellent interobserver and intraobserver reliability in this dementia population. This study contributes to the validation process of the OPS-NVI as a whole and stresses the need for further assessment of the reliability of the OPS-NVI with subjects that might already show signs of orofacial pain.
ERIC Educational Resources Information Center
St Clair-Thompson, Helen
2014-01-01
The aim of the present study was to investigate the reliability and validity of a brief standardized assessment of children's working memory; "Lucid Recall." Although there are many established assessments of working memory, "Lucid Recall" is fully automated and can therefore be administered in a group setting. It is therefore…
Hosseini, Mohammad-Parsa; Nazem-Zadeh, Mohammad-Reza; Pompili, Dario; Jafari-Khouzani, Kourosh; Elisevich, Kost; Soltanian-Zadeh, Hamid
2016-01-01
Segmentation of the hippocampus from magnetic resonance (MR) images is a key task in the evaluation of mesial temporal lobe epilepsy (mTLE) patients. Several automated algorithms have been proposed although manual segmentation remains the benchmark. Choosing a reliable algorithm is problematic since structural definition pertaining to multiple edges, missing and fuzzy boundaries, and shape changes varies among mTLE subjects. Lack of statistical references and guidance for quantifying the reliability and reproducibility of automated techniques has further detracted from automated approaches. The purpose of this study was to develop a systematic and statistical approach using a large dataset for the evaluation of automated methods and establish a method that would achieve results better approximating those attained by manual tracing in the epileptogenic hippocampus. A template database of 195 (81 males, 114 females; age range 32-67 yr, mean 49.16 yr) MR images of mTLE patients was used in this study. Hippocampal segmentation was accomplished manually and by two well-known tools (FreeSurfer and hammer) and two previously published methods developed at their institution [Automatic brain structure segmentation (ABSS) and LocalInfo]. To establish which method was better performing for mTLE cases, several voxel-based, distance-based, and volume-based performance metrics were considered. Statistical validations of the results using automated techniques were compared with the results of benchmark manual segmentation. Extracted metrics were analyzed to find the method that provided a more similar result relative to the benchmark. Among the four automated methods, ABSS generated the most accurate results. For this method, the Dice coefficient was 5.13%, 14.10%, and 16.67% higher, Hausdorff was 22.65%, 86.73%, and 69.58% lower, precision was 4.94%, -4.94%, and 12.35% higher, and the root mean square (RMS) was 19.05%, 61.90%, and 65.08% lower than LocalInfo, FreeSurfer, and hammer, respectively. The Bland-Altman similarity analysis revealed a low bias for the ABSS and LocalInfo techniques compared to the others. The ABSS method for automated hippocampal segmentation outperformed other methods, best approximating what could be achieved by manual tracing. This study also shows that four categories of input data can cause automated segmentation methods to fail. They include incomplete studies, artifact, low signal-to-noise ratio, and inhomogeneity. Different scanner platforms and pulse sequences were considered as means by which to improve reliability of the automated methods. Other modifications were specially devised to enhance a particular method assessed in this study.
Pinchi, Vilma; De Luca, Federica; Ricciardi, Federico; Focardi, Martina; Piredda, Valentina; Mazzeo, Elena; Norelli, Gian-Aristide
2014-05-01
Paediatricians, radiologists, anthropologists and medico-legal specialists are often called as experts in order to provide age estimation (AE) for forensic purposes. The literature recommends performing the X-rays of the left hand and wrist (HW-XR) for skeletal age estimation. The method most frequently employed is the Greulich and Pyle (GP) method. In addition, the so-called bone-specific techniques are also applied including the method of Tanner Whitehouse (TW) in the latest versions TW2 and TW3. To compare skeletal age and chronological age in a large sample of children and adolescents using GP, TW2 and TW3 methods in order to establish which of these is the most reliable for forensic purposes. The sample consisted of 307 HW-XRs of Italian children or adolescents, 145 females and 162 males aged between 6 and 20 years. The radiographies were scored according to the GP, TW2RUS and TW3RUS methods by one investigator. The results' reliability was assessed using intraclass correlation coefficient. Wilcoxon signed-rank test and Student t-test were performed to search for significant differences between skeletal and chronological ages. The distributions of the differences between estimated and chronological age, by means of boxplots, show how median differences for TW3 and GP methods are generally very close to 0. Hypothesis tests' results were obtained, with respect to the sex, both for the entire group of individuals and people grouped by age. Results show no significant differences among estimated and chronological age for TW3 and, to a lesser extent, GP. The TW2 proved to be the worst of the three methods. Our results support the conclusion that the TW2 method is not reliable for AE for forensic purpose. The GP and TW3 methods have proved to be reliable in males. For females, the best method was found to be TW3. When performing forensic age estimation in subjects around 14 years of age, it could be advisable to use and associate the TW3 and GP methods. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Proteomic Approaches in Biomarker Discovery: New Perspectives in Cancer Diagnostics
Kocevar, Nina; Komel, Radovan
2014-01-01
Despite remarkable progress in proteomic methods, including improved detection limits and sensitivity, these methods have not yet been established in routine clinical practice. The main limitations, which prevent their integration into clinics, are high cost of equipment, the need for highly trained personnel, and last, but not least, the establishment of reliable and accurate protein biomarkers or panels of protein biomarkers for detection of neoplasms. Furthermore, the complexity and heterogeneity of most solid tumours present obstacles in the discovery of specific protein signatures, which could be used for early detection of cancers, for prediction of disease outcome, and for determining the response to specific therapies. However, cancer proteome, as the end-point of pathological processes that underlie cancer development and progression, could represent an important source for the discovery of new biomarkers and molecular targets for tailored therapies. PMID:24550697
Reliability evaluation of oil pipelines operating in aggressive environment
NASA Astrophysics Data System (ADS)
Magomedov, R. M.; Paizulaev, M. M.; Gebel, E. S.
2017-08-01
In connection with modern increased requirements for ecology and safety, the development of diagnostic services complex is obligatory and necessary enabling to ensure the reliable operation of the gas transportation infrastructure. Estimation of oil pipelines technical condition should be carried out not only to establish the current values of the equipment technological parameters in operation, but also to predict the dynamics of changes in the physical and mechanical characteristics of the material, the appearance of defects, etc. to ensure reliable and safe operation. In the paper, existing Russian and foreign methods for evaluation of the oil pipelines reliability are considered, taking into account one of the main factors leading to the appearance of crevice in the pipeline material, i.e. change the shape of its cross-section, - corrosion. Without compromising the generality of the reasoning, the assumption of uniform corrosion wear for the initial rectangular cross section has been made. As a result a formula for calculation the probability of failure-free operation was formulated. The proposed mathematical model makes it possible to predict emergency situations, as well as to determine optimal operating conditions for oil pipelines.
NASA Astrophysics Data System (ADS)
Yang, Linlin; Sun, Hai; Fu, Xudong; Wang, Suli; Jiang, Luhua; Sun, Gongquan
2014-07-01
A novel method for measuring effective diffusion coefficient of porous materials is developed. The oxygen concentration gradient is established by an air-breathing proton exchange membrane fuel cell (PEMFC). The porous sample is set in a sample holder located in the cathode plate of the PEMFC. At a given oxygen flux, the effective diffusion coefficients are related to the difference of oxygen concentration across the samples, which can be correlated with the differences of the output voltage of the PEMFC with and without inserting the sample in the cathode plate. Compared to the conventional electrical conductivity method, this method is more reliable for measuring non-wetting samples.
Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire
Akmaz, Hazel Ekin; Uyar, Meltem; Kuzeyli Yıldırım, Yasemin; Akın Korhan, Esra
2018-05-29
Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Methodological and cross sectional study. A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance of chronic pain.
Shen, Qing; Dai, Zhiyuan; Lu, Yanbin
2010-10-01
An ultra-fast high-performance LC-ESI-MS/MS method was developed for the analysis and quantification of caffeoylquinic acid derivatives, including chlorogenic acid, 1,3-di-O-caffeoylquinic acid (cynarin) and 1,5-di-O-caffeoylquinic acid, in artichoke (Cynara scolymus L.) heads and leaves. The rapid separation (less than 4 min) was achieved based on a Halo fused core C18-silica column (50 mm × 2.1 mm id, 2.7 μm). The target compounds were detected and quantified by a triple-quadrupole mass spectrometer in multiple-reaction monitoring mode. The calibration function is linear from 0.06 to 2800 ng/mL for chlorogenic acid, 0.3-3000 ng/mL for cynarin and 0.24-4800 ng/mL for 1,5-di-O-caffeoylquinic acid, respectively. The average recoveries ranged from 92.1 to 113.2% with RSDs ≤6.5%. Moreover, four batches of artichoke head and leaf extracts were analyzed using the established method. The results indicated that the Halo fused core column provided much faster separations and higher sample throughput without sacrificing column ruggedness and reliability, and triple-quadrupole MS provided extraordinarily lower LOQs for most of the target analytes. Comparing to conventional quantitative approaches, the established method was fast, sensitive and reliable for the determination of caffeoylquinic acid derivatives in artichoke.
Lu, Hai-Lin; Guo, Min; Liao, Yue-Kui; Huang, Ding-Ying; Huang, Chun-Ni; Wu, Xiao-Chen; He, Bao-Zuo
2012-11-01
To study the identification characters of Houttuynia cordata and its confused herb Gymnotheca chinensis and establish an identification method. LMVP (leaf morphological-venation pattern for identification Chinese herbs), and QAERM (quantitatively analyze and evaluate reliability for the method of identification Chinese herbs) were applied for the study. Both venations were brochidodromous-acrodromous and arising from the mid-petiole or the upper section of petiole. The main characteristic of the leaf of Houttuynia cordata: surface with small gray-white stoma protuberances; Ligulate process of stipule-petiole sheath were clear; Primary veins 7 or 5; The innermost pair of primary vein closed up the top of the sinus at blade base or above sinus, and the section of closed vein was straight; Emitted a smell of fish when fresh leaf was kneaded into pieces. The main feature of the leaf of Gymnotheca chinensis: no small gray-white stoma protuberances; Ligulate process of stipule-petiole sheath were not clear; Primary veins 5; The innermost pair of primary vein closed into the sinus at blade base, and the section of closed vein was slightly curve; No smell of fish. With the mentioned key differences, the both plants could be successfully identified from each other. The accuracy of identification results (AC) was 100%, the repeatability of identification results: agreement rate for observation (ARO) was 100% and Kappa value was 1.00. The established method is simple, rapid, economic and reliable.
Reliability analysis of different structure parameters of PCBA under drop impact
NASA Astrophysics Data System (ADS)
Liu, P. S.; Fan, G. M.; Liu, Y. H.
2018-03-01
The establishing process of PCBA is modelled by finite element analysis software ABAQUS. Firstly, introduce the Input-G method and the fatigue life under drop impact are introduced and the mechanism of the solder joint failure in the process of drop is analysed. The main reason of solder joint failure is that the PCB component is suffering repeated tension and compression stress during the drop impact. Finally, the equivalent stress and peel stress of different solder joint and plate-level components under different impact acceleration are also analysed. The results show that the reliability of tin-silver copper joint is better than that of tin- lead solder joint, and the fatigue life of solder joint expectancy decrease as the impact pulse amplitude increases.
The Wartegg Zeichen Test: a literature overview and a meta-analysis of reliability and validity.
Soilevuo Grønnerød, Jarna; Grønnerød, Cato
2012-06-01
All available studies on the Wartegg Zeichen Test (WZT; Wartegg, 1939) were collected and evaluated through a literature overview and a meta-analysis. The literature overview shows that the history of the WZT reflects the geographical and language-based processes of marginalization where relatively isolated traditions have lived and vanished in different parts of the world. The meta-analytic review indicates a high average interscorer reliability of rw = .74 and high validity effect size for studies with clear hypotheses of rw = .33. Although the results were strong, we conclude that the WZT research has not been able to establish cumulative knowledge of the method because of the isolation of research traditions. (c) 2012 APA, all rights reserved
EDRN Standard Operating Procedures (SOP) — EDRN Public Portal
The NCI’s Early Detection Research Network is developing a number of standard operating procedures for assays, methods, and protocols for collection and processing of biological samples, and other reference materials to assist investigators to conduct experiments in a consistent, reliable manner. These SOPs are established by the investigators of the Early Detection Research Network to maintain constancy throughout the Network. These SOPs represent neither a consensus, nor are the recommendations of NCI.
Paini, Dean R.; Bianchi, Felix J. J. A.; Northfield, Tobin D.; De Barro, Paul J.
2011-01-01
Predicting future species invasions presents significant challenges to researchers and government agencies. Simply considering the vast number of potential species that could invade an area can be insurmountable. One method, recently suggested, which can analyse large datasets of invasive species simultaneously is that of a self organising map (SOM), a form of artificial neural network which can rank species by establishment likelihood. We used this method to analyse the worldwide distribution of 486 fungal pathogens and then validated the method by creating a virtual world of invasive species in which to test the SOM. This novel validation method allowed us to test SOM's ability to rank those species that can establish above those that can't. Overall, we found the SOM highly effective, having on average, a 96–98% success rate (depending on the virtual world parameters). We also found that regions with fewer species present (i.e. 1–10 species) were more difficult for the SOM to generate an accurately ranked list, with success rates varying from 100% correct down to 0% correct. However, we were able to combine the numbers of species present in a region with clustering patterns in the SOM, to further refine confidence in lists generated from these sparsely populated regions. We then used the results from the virtual world to determine confidences for lists generated from the fungal pathogen dataset. Specifically, for lists generated for Australia and its states and territories, the reliability scores were between 84–98%. We conclude that a SOM analysis is a reliable method for analysing a large dataset of potential invasive species and could be used by biosecurity agencies around the world resulting in a better overall assessment of invasion risk. PMID:22016773
Paini, Dean R; Bianchi, Felix J J A; Northfield, Tobin D; De Barro, Paul J
2011-01-01
Predicting future species invasions presents significant challenges to researchers and government agencies. Simply considering the vast number of potential species that could invade an area can be insurmountable. One method, recently suggested, which can analyse large datasets of invasive species simultaneously is that of a self organising map (SOM), a form of artificial neural network which can rank species by establishment likelihood. We used this method to analyse the worldwide distribution of 486 fungal pathogens and then validated the method by creating a virtual world of invasive species in which to test the SOM. This novel validation method allowed us to test SOM's ability to rank those species that can establish above those that can't. Overall, we found the SOM highly effective, having on average, a 96-98% success rate (depending on the virtual world parameters). We also found that regions with fewer species present (i.e. 1-10 species) were more difficult for the SOM to generate an accurately ranked list, with success rates varying from 100% correct down to 0% correct. However, we were able to combine the numbers of species present in a region with clustering patterns in the SOM, to further refine confidence in lists generated from these sparsely populated regions. We then used the results from the virtual world to determine confidences for lists generated from the fungal pathogen dataset. Specifically, for lists generated for Australia and its states and territories, the reliability scores were between 84-98%. We conclude that a SOM analysis is a reliable method for analysing a large dataset of potential invasive species and could be used by biosecurity agencies around the world resulting in a better overall assessment of invasion risk.
[Reliability of HOMA-IR for evaluation of insulin resistance during perioperative period].
Fujino, Hiroko; Itoda, Shoko; Sako, Saori; Matsuo, Kazuki; Sakamoto, Eiji; Yokoyama, Takeshi
2013-02-01
Hyperglycemia due to increase in insulin resistance (IR) is often observed after surgery in spite of normal insulin secretion. To evaluate the degree of IR, the golden standard method is the normoglycemic hyperinsulinemic clamp technique (glucose clamp: GC). The GC using the artificial pancreas, STG-22 (Nikkiso, Tokyo, Japan), was established as a more reliable method, since it was evaluated during steady-state period under constant insulin infusion. Homeostasis model assessment insulin resistance (HOMA-IR), however, is frequently employed in daily practice because of its convenience. We, therefore, investigated the reliability of HOMA-IR in comparison with the glucose clamp using the STG-22. Eight healthy patients undergoing maxillofacial surgery were employed in this study after obtaining written informed consent. Their insulin resistance was evaluated by HOMA-IR and the GC using the STG-22 before and after surgery. HOMA-IR increased from 0.81 +/- 0.48 to 1.17 +/- 0.50, although there were no significant differences between before and after surgery. On the other hand, M-value by GC significantly decreased after surgery from 8.82 +/- 2.49 mg x kg(-1) x min(-1) to 3.84 +/- 0.79 mg x kg(-1) x min(-1) (P = 0.0003). In addition, no significant correlation was found between the values of HOMA-IR and the M-value by GC. HOMA-IR may not be reliable to evaluate IR for perioperative period.
Torsional resonance frequency analysis: a novel method for assessment of dental implant stability.
Tang, Yu-Long; Li, Bing; Jin, Wei; Li, De-Hua
2015-06-01
To establish and experimentally validate a novel resonance frequency analysis (RFA) method for measurement of dental implant stability by analyzing torsional resonance frequency (TRF). A numerical study and in vitro measurements were performed to evaluate the feasibility and reliability of the method of torsional RFA (T-RFA) using a T-shaped bilateral cantilever beam transducer. The sensitivity of this method was assessed by measuring the TRFs of dental implants with 8 sizes of T-shaped transducers during polymerization, which simulated the process of bone healing around an implant. The TRFs of the test implants detected using this new method and the bending resonance frequencies (BRFs) measured by Osstell(®) ISQ were compared. TRFs and BRFs on implant models in polymethyl methacrylate (PMMA) blocks with three exposure heights were also measured to assess the specificity of this method. Finite element analysis showed two bending modes (5333 and 6008 Hz) following a torsional mode (8992 Hz) in the lower rank frequency. During in vitro measurements, a bending formant (mean 6075 Hz) and a torsional formant (mean 10225 Hz) appeared, which were verified by multipoint measurement with invariable excitation frequency in the laboratory. In the self-curing resin experiments, the average growth rate at all time points of TRFs using the new method with Transducer II was 2.36% and that of BRFs using Osstell(®) ISQ was 1.97%. In the implant exposure height tests, the mean declined rate of TRFs was 2.06% and that of BRFs using Osstell(®) ISQ was 12.34%. A novel method for assessment of implant stability through TRF was established using a T-shape transducer, which showed high reliability and sensibility. The method alleviated the effects of implant exposure height on the measurements compared with Osstell(®) ISQ. The application of T-RFA represents another way in the investigation of dental implant osseointegration. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sarig Bahat, Hilla; Sprecher, Elliot; Sela, Itamar; Treleaven, Julia
2016-07-01
The use of virtual reality (VR) for assessment and intervention of neck pain has previously been used and shown reliable for cervical range of motion measures. Neck VR enables analysis of task-oriented neck movement by stimulating responsive movements to external stimuli. Therefore, the purpose of this study was to establish inter-tester reliability of neck kinematic measures so that it can be used as a reliable assessment and treatment tool between clinicians. This reliability study included 46 asymptomatic participants, who were assessed using the neck VR system which displayed an interactive VR scenario via a head-mounted device, controlled by neck movements. The objective of the interactive assessment was to hit 16 targets, randomly appearing in four directions, as fast as possible. Each participant was tested twice by two different testers. Good reliability was found of neck motion kinematic measures in flexion, extension, and rotation (0.64-0.93 inter-class correlation). High reliability was shown for peak velocity globally (0.93), in left rotation (0.9), right rotation and extension (0.88), and flexion (0.86). Mean velocity had a good global reliability (0.84), except for left rotation directed movement with moderate reliability (0.68). Minimal detectable change for peak velocity ranged from 41 to 53 °/s, while mean velocity ranged from 20 to 25 °/s. The results suggest high reliability for peak and mean velocity as measured by the interactive Neck VR assessment of neck motion kinematics. VR appears to provide a reliable and more ecologically valid method of cervical motion evaluation than previous conventional methodologies.
Reliability of videotaped observational gait analysis in patients with orthopedic impairments
Brunnekreef, Jaap J; van Uden, Caro JT; van Moorsel, Steven; Kooloos, Jan GM
2005-01-01
Background In clinical practice, visual gait observation is often used to determine gait disorders and to evaluate treatment. Several reliability studies on observational gait analysis have been described in the literature and generally showed moderate reliability. However, patients with orthopedic disorders have received little attention. The objective of this study is to determine the reliability levels of visual observation of gait in patients with orthopedic disorders. Methods The gait of thirty patients referred to a physical therapist for gait treatment was videotaped. Ten raters, 4 experienced, 4 inexperienced and 2 experts, individually evaluated these videotaped gait patterns of the patients twice, by using a structured gait analysis form. Reliability levels were established by calculating the Intraclass Correlation Coefficient (ICC), using a two-way random design and based on absolute agreement. Results The inter-rater reliability among experienced raters (ICC = 0.42; 95%CI: 0.38–0.46) was comparable to that of the inexperienced raters (ICC = 0.40; 95%CI: 0.36–0.44). The expert raters reached a higher inter-rater reliability level (ICC = 0.54; 95%CI: 0.48–0.60). The average intra-rater reliability of the experienced raters was 0.63 (ICCs ranging from 0.57 to 0.70). The inexperienced raters reached an average intra-rater reliability of 0.57 (ICCs ranging from 0.52 to 0.62). The two expert raters attained ICC values of 0.70 and 0.74 respectively. Conclusion Structured visual gait observation by use of a gait analysis form as described in this study was found to be moderately reliable. Clinical experience appears to increase the reliability of visual gait analysis. PMID:15774012
Gunnarsson, U; Johansson, M; Strigård, K
2011-08-01
The decrease in recurrence rates in ventral hernia surgery have led to a redirection of focus towards other important patient-related endpoints. One such endpoint is abdominal wall function. The aim of the present study was to evaluate the reliability and external validity of abdominal wall strength measurement using the Biodex System-4 with a back abdomen unit. Ten healthy volunteers and ten patients with ventral hernias exceeding 10 cm were recruited. Test-retest reliability, both with and without girdle, was evaluated by comparison of measurements at two test occasions 1 week apart. Reliability was calculated by the interclass correlation coefficients (ICC) method. Validity was evaluated by correlation with the well-established International Physical Activity Questionnaire (IPAQ) and a self-assessment of abdominal wall strength. One person in the healthy group was excluded after the first test due to neck problems following minor trauma. The reliability was excellent (>0.75), with ICC values between 0.92 and 0.97 for the different modalities tested. No differences were seen between testing with and without a girdle. Validity was also excellent both when calculated as correlation to self-assessment of abdominal wall strength, and to IPAQ, giving Kendall tau values of 0.51 and 0.47, respectively, and corresponding P values of 0.002 and 0.004. Measurement of abdominal muscle function using the Biodex System-4 is a reliable and valid method to assess this important patient-related endpoint. Further investigations will be made to explore the potential of this technique in the evaluation of the results of ventral hernia surgery, and to compare muscle function after different abdominal wall reconstruction techniques.
RELIABILITY AND VALIDITY OF A BIOMECHANICALLY BASED ANALYSIS METHOD FOR THE TENNIS SERVE
Kibler, W. Ben; Lamborn, Leah; Smith, Belinda J.; English, Tony; Jacobs, Cale; Uhl, Tim L.
2017-01-01
Background An observational tennis serve analysis (OTSA) tool was developed using previously established body positions from three-dimensional kinematic motion analysis studies. These positions, defined as nodes, have been associated with efficient force production and minimal joint loading. However, the tool has yet to be examined scientifically. Purpose The primary purpose of this investigation was to determine the inter-observer reliability for each node between two health care professionals (HCPs) that developed the OTSA, and secondarily to investigate the validity of the OTSA. Methods Two separate studies were performed to meet these objectives. An inter-observer reliability study preceded the validity study by examining 28 videos of players serving. Two HCPs graded each video and scored the presence or absence of obtaining each node. Discriminant validity was determined in 33 tennis players using video taped records of three first serves. Serve mechanics were graded using the OSTA and categorized players into those with good ( ≥ 5) and poor ( ≤ 4) mechanics. Participants performed a series of field tests to evaluate trunk flexibility, lower extremity and trunk power, and dynamic balance. Results The group with good mechanics demonstrated greater backward trunk flexibility (p=0.02), greater rotational power (p=0.02), and higher single leg countermovement jump (p=0.05). Reliability of the OTSA ranged from K = 0.36-1.0, with the majority of all the nodes displaying substantial reliability (K>0.61). Conclusion This study provides HCPs with a valid and reliable field tool used to assess serve mechanics. Physical characteristics of trunk mobility and power appear to discriminate serve mechanics between players. Future intervention studies are needed to determine if improvement in physical function contribute to improved serve mechanics. Level of Evidence 3 PMID:28593098
A Critical Comparison of Methods for the Analysis of Indigo in Dyeing Liquors and Effluents
Buscio, Valentina; Crespi, Martí; Gutiérrez-Bouzán, Carmen
2014-01-01
Indigo is one of the most important dyes in the textile industry. The control of the indigo concentration in dyeing liquors and effluents is an important tool to ensure the reproducibility of the dyed fabrics and also to establish the efficiency of the wastewater treatment. In this work, three analytical methods were studied and validated with the aim to select a reliable, fast and automated method for the indigo dye determination. The first method is based on the extraction of the dye, with chloroform, in its oxidized form. The organic solution is measured by Ultraviolet (UV)-visible spectrophotometry at 604 nm. The second method determines the concentration of indigo in its leuco form in aqueous medium by UV-visible spectrophotometry at 407 nm. Finally, in the last method, the concentration of indigo is determined by redox titration with potassium hexacyanoferrate (K3(Fe(CN)6)). The results indicated that the three methods that we studied met the established acceptance criteria regarding accuracy and precision. However, the third method was considered the most adequate for application on an industrial scale due to its wider work range, which provides a significant advantage over the others. PMID:28788185
Song, Jing-Zheng; Han, Quan-Bin; Qiao, Chun-Feng; But, Paul Pui-Hay; Xu, Hong-Xi
2010-01-01
Aconites, with aconite alkaloids as the major therapeutic and toxic components, are used for the treatment of analgesic, antirheumatic and neurological symptoms. Quantification of the aconite alkaloids is important for the quality control of aconite-containing drugs. To establish a validated capillary zone electrophoresis (CZE) method for the simultaneous determination of six major alkaloids, namely aconitine, mesaconitine, hypaconitine, benzoylaconine, benzoylmesaconine and benzoylhypaconine, in crude and processed aconite roots. The CZE method was optimised and validated using a stability-indicating method. The optimised running buffer was a mixture of 200 mm Tris, 150 mm perchloric acid and 40% 1,4-dioxane (pH 7.8) with the capillary thermostated at 25 degrees C. Using the optimised method, six aconite alkaloids were well separated. The established method showed good precision, accuracy and recovery. Contents of these alkaloids in crude and processed aconites were determined and it was observed that the levels of individual alkaloids varied between samples. The developed CZE method was reliable for the quality control of aconites contained in herbal medicines. The method could also be used as an approach for toxicological studies.
FY12 End of Year Report for NEPP DDR2 Reliability
NASA Technical Reports Server (NTRS)
Guertin, Steven M.
2013-01-01
This document reports the status of the NASA Electronic Parts and Packaging (NEPP) Double Data Rate 2 (DDR2) Reliability effort for FY2012. The task expanded the focus of evaluating reliability effects targeted for device examination. FY11 work highlighted the need to test many more parts and to examine more operating conditions, in order to provide useful recommendations for NASA users of these devices. This year's efforts focused on development of test capabilities, particularly focusing on those that can be used to determine overall lot quality and identify outlier devices, and test methods that can be employed on components for flight use. Flight acceptance of components potentially includes considerable time for up-screening (though this time may not currently be used for much reliability testing). Manufacturers are much more knowledgeable about the relevant reliability mechanisms for each of their devices. We are not in a position to know what the appropriate reliability tests are for any given device, so although reliability testing could be focused for a given device, we are forced to perform a large campaign of reliability tests to identify devices with degraded reliability. With the available up-screening time for NASA parts, it is possible to run many device performance studies. This includes verification of basic datasheet characteristics. Furthermore, it is possible to perform significant pattern sensitivity studies. By doing these studies we can establish higher reliability of flight components. In order to develop these approaches, it is necessary to develop test capability that can identify reliability outliers. To do this we must test many devices to ensure outliers are in the sample, and we must develop characterization capability to measure many different parameters. For FY12 we increased capability for reliability characterization and sample size. We increased sample size this year by moving from loose devices to dual inline memory modules (DIMMs) with an approximate reduction of 20 to 50 times in terms of per device under test (DUT) cost. By increasing sample size we have improved our ability to characterize devices that may be considered reliability outliers. This report provides an update on the effort to improve DDR2 testing capability. Although focused on DDR2, the methods being used can be extended to DDR and DDR3 with relative ease.
Guohua, Xia; Pan, Ruirong; Bao, Rui; Ge, Yanru; Zhou, Cunshan; Shen, Yuping
2017-01-01
Sanghuang is one of mystical traditional Chinese medicines recorded earliest 2000 years ago, that included various fungi of Inonotus genus and was well-known for antitumor effect in modern medicine. Inonotus vaninii is grown in natural forest of Northeastern China merely and used as Sanghuang commercially, but it has no quality control specification until now. This study was to establish a rapid method of two-phase acid hydrolysis followed by reversed phase-high performance liquid chromatography-ultra violet (RP-HPLC-UV) to quantify naringenin in the fruit body of I. vaninii . Sample solution was prepared by pretreatment of raw material in two-phase acid hydrolysis and the hydrolysis technology was optimized. After reconstitution, analysis was performed using RP-HPLC-UV. The method validation was investigated and the naringenin content of sample and comparison were determined. The naringenin was obtained by two-phase acid hydrolysis method, namely, 10.0 g of raw material was hydrolyzed in 200 mL of 1% sulfuric acid aqueous solution (v/v) and 400 mL of chloroform in oil bath at 110°C for 2 h. Good linearity ( r = 0.9992) was achieved between concentration of analyte and peak area. The relative standard deviation (RSD) of precision was 2.47% and the RSD of naringenin contents for repeatability was 3.13%. The accuracy was supported with recoveries at 96.37%, 97.30%, and 99.31%. The sample solution prepared using the proposed method contained higher content of naringenin than conventional method and was stable for 8 h. Due to the high efficiency of sample preparation and high reliability of the HPLC method, it is feasible to use this method for routine analysis of naringenin in the fungus. A convenient two-phase acid hydrolysis was employed to produce naringenin from raw material, and then an efficient and reliable reversed phase-high performance liquid chromatography-ultra violet method was established to monitor naringenin in the fruit bodies of Inonotus vaninii . The newly established method could be used to control the quality of the herb. Abbreviations used: RP-HPLC-UV: Reversed Phase-High Performance Liquid Chromatography-Ultra Violet, RSD: Relative Standard Deviation, EtOAc: Ethyl acetate, ACN: Acetonitrile, MeOH: Methanol, RH: Relative Humility.
Mohammed, Rezwana Begum; Kalyan, V. Siva; Tircouveluri, Saritha; Vegesna, Goutham Chakravarthy; Chirla, Anil; Varma, D. Maruthi
2014-01-01
Introduction: Determining the age of a person in the absence of documentary evidence of birth is essential for legal and medico-legal purpose. Fishman method of skeletal maturation is widely used for this purpose; however, the reliability of this method for people with all geographic locations is not well-established. Aims and Objectives: In this study, we assessed various stages of carpal and metacarpal bone maturation and tested the reliability of Fishman method of skeletal maturation to estimate the age in South Indian population. We also evaluated the correlation between the chronological age (CA) and predicted age based on the Fishman method of skeletal maturation. Materials and Methods: Digital right hand-wrist radiographs of 330 individuals aged 9-20 years were obtained and the skeletal maturity stage for each subject was determined using Fishman method. The skeletal maturation indicator scores were obtained and analyzed with reference to CA and sex. Data was analyzed using the SPSS software package (version 12, SPSS Inc., Chicago, IL, USA). Results: The study subjects had a tendency toward late maturation with the mean skeletal age (SA) estimated being significantly lowers (P < 0.05) than the mean CA at various skeletal maturity stages. Nevertheless, significant correlation was observed in this study between SA and CA for males (r = 0.82) and females (r = 0.85). Interestingly, female subjects were observed to be advanced in SA compared with males. Conclusion: Fishman method of skeletal maturation can be used as an alternative tool for the assessment of mean age of an individual of unknown CA in South Indian children. PMID:25097402
Mischiati, Carolina R.; Comerford, Mark; Gosford, Emma; Swart, Jacqueline; Ewings, Sean; Botha, Nadine; Stokes, Maria; Mottram, Sarah L.
2015-01-01
Pre-season screening is well established within the sporting arena, and aims to enhance performance and reduce injury risk. With the increasing need to identify potential injury with greater accuracy, a new risk assessment process has been produced; The Performance Matrix (battery of movement control tests). As with any new method of objective testing, it is fundamental to establish whether the same results can be reproduced between examiners and by the same examiner on consecutive occasions. This study aimed to determine the intra-rater test re-test and inter-rater reliability of tests from a component of The Performance Matrix, The Foundation Matrix. Twenty participants were screened by two experienced musculoskeletal therapists using nine tests to assess the ability to control movement during specific tasks. Movement evaluation criteria for each test were rated as pass or fail. The therapists observed participants real-time and tests were recorded on video to enable repeated ratings four months later to examine intra-rater reliability (videos rated two weeks apart). Overall test percentage agreement was 87% for inter-rater reliability; 98% Rater 1, 94% Rater 2 for test re-test reliability; and 75% for real-time versus video. Intraclass-correlation coefficients (ICCs) were excellent between raters (0.81) and within raters (Rater 1, 0.96; Rater 2, 0.88) but poor for real-time versus video (0.23). Reliability for individual components of each test was more variable: inter-rater, 68-100%; intra-rater, 88-100% Rater 1, 75-100% Rater 2; and real-time versus video 31-100%. Cohen’s Kappa values for inter-rater reliability were 0.0-1.0; intra-rater 0.6-1.0 for Rater 1; -0.1-1.0 for Rater 2; and -0.1-1 for real-time versus video. It is concluded that both inter and intra-rater reliability of tests in The Foundation Matrix are acceptable when rated by experienced therapists. Recommendations are made for modifying some of the criteria to improve reliability where excellence was not reached. Key points The movement control tests of The Foundation Matrix had acceptable reliability between raters and within raters on different days Agreement between observations made on tests performed real-time and on video recordings was low, indicating poor validity of use of video recordings Some movement evaluation criteria related to specific tests that did not achieve excellent agreement could be modified to improve reliability PMID:25983594
78 FR 49595 - Aviation Rulemaking Advisory Committee-New Task
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-14
... the new ARAC activity and solicits membership for the Maintenance Reliability Program Working Group... establish the Maintenance Reliability Program Working Group. The working group will serve as staff to ARAC... programs. The Maintenance Reliability Program Working Group will provide advice and recommendations on the...
10 CFR 712.12 - HRP implementation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the Human Reliability...) Report any observed or reported behavior or condition of another HRP-certified individual that could indicate a reliability concern, including those behaviors and conditions listed in § 712.13(c), to a...
Proposed reliability cost model
NASA Technical Reports Server (NTRS)
Delionback, L. M.
1973-01-01
The research investigations which were involved in the study include: cost analysis/allocation, reliability and product assurance, forecasting methodology, systems analysis, and model-building. This is a classic example of an interdisciplinary problem, since the model-building requirements include the need for understanding and communication between technical disciplines on one hand, and the financial/accounting skill categories on the other. The systems approach is utilized within this context to establish a clearer and more objective relationship between reliability assurance and the subcategories (or subelements) that provide, or reenforce, the reliability assurance for a system. Subcategories are further subdivided as illustrated by a tree diagram. The reliability assurance elements can be seen to be potential alternative strategies, or approaches, depending on the specific goals/objectives of the trade studies. The scope was limited to the establishment of a proposed reliability cost-model format. The model format/approach is dependent upon the use of a series of subsystem-oriented CER's and sometimes possible CTR's, in devising a suitable cost-effective policy.
Lessons learned applying CASE methods/tools to Ada software development projects
NASA Technical Reports Server (NTRS)
Blumberg, Maurice H.; Randall, Richard L.
1993-01-01
This paper describes the lessons learned from introducing CASE methods/tools into organizations and applying them to actual Ada software development projects. This paper will be useful to any organization planning to introduce a software engineering environment (SEE) or evolving an existing one. It contains management level lessons learned, as well as lessons learned in using specific SEE tools/methods. The experiences presented are from Alpha Test projects established under the STARS (Software Technology for Adaptable and Reliable Systems) project. They reflect the front end efforts by those projects to understand the tools/methods, initial experiences in their introduction and use, and later experiences in the use of specific tools/methods and the introduction of new ones.
Barnini, Simona; Ghelardi, Emilia; Brucculeri, Veronica; Morici, Paola; Lupetti, Antonella
2015-06-18
Rapid identification of the causative agent(s) of bloodstream infections using the matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) methodology can lead to increased empirical antimicrobial therapy appropriateness. Herein, we aimed at establishing an easier and simpler method, further referred to as the direct method, using bacteria harvested by serum separator tubes from positive blood cultures and placed onto the polished steel target plate for rapid identification by MALDI-TOF. The results by the direct method were compared with those obtained by MALDI-TOF on bacteria isolated on solid media. Identification of Gram-negative bacilli was 100 % concordant using the direct method or MALDI-TOF on isolated bacteria (96 % with score > 2.0). These two methods were 90 % concordant on Gram-positive cocci (32 % with score > 2.0). Identification by the SepsiTyper method of Gram-positive cocci gave concordant results with MALDI-TOF on isolated bacteria in 87 % of cases (37 % with score > 2.0). The direct method herein developed allows rapid identification (within 30 min) of Gram-negative bacteria and Gram-positive cocci from positive blood cultures and can be used to rapidly report reliable and accurate results, without requiring skilled personnel or the use of expensive kits.
Gwynne, Craig R; Curran, Sarah A
2014-12-01
Clinical assessment of lower limb kinematics during dynamic tasks may identify individuals who demonstrate abnormal movement patterns that may lead to etiology of exacerbation of knee conditions such as patellofemoral joint (PFJt) pain. The purpose of this study was to determine the reliability, validity and associated measurement error of a clinically appropriate two-dimensional (2-D) procedure of quantifying frontal plane knee alignment during single limb squats. Nine female and nine male recreationally active subjects with no history of PFJt pain had frontal plane limb alignment assessed using three-dimensional (3-D) motion analysis and digital video cameras (2-D analysis) while performing single limb squats. The association between 2-D and 3-D measures was quantified using Pearson's product correlation coefficients. Intraclass correlation coefficients (ICCs) were determined for within- and between-session reliability of 2-D data and standard error of measurement (SEM) was used to establish measurement error. Frontal plane limb alignment assessed with 2-D analysis demonstrated good correlation compared with 3-D methods (r = 0.64 to 0.78, p < 0.001). Within-session (0.86) and between-session ICCs (0.74) demonstrated good reliability for 2-D measures and SEM scores ranged from 2° to 4°. 2-D measures have good consistency and may provide a valid measure of lower limb alignment when compared to existing 3-D methods. Assessment of lower limb kinematics using 2-D methods may be an accurate and clinically useful alternative to 3-D motion analysis when identifying individuals who demonstrate abnormal movement patterns associated with PFJt pain. 2b.
Tactile Acuity Charts: A Reliable Measure of Spatial Acuity
Bruns, Patrick; Camargo, Carlos J.; Campanella, Humberto; Esteve, Jaume; Dinse, Hubert R.; Röder, Brigitte
2014-01-01
For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds. PMID:24504346
UV Spectrophotometric Method for Estimation of Polypeptide-K in Bulk and Tablet Dosage Forms
NASA Astrophysics Data System (ADS)
Kaur, P.; Singh, S. Kumar; Gulati, M.; Vaidya, Y.
2016-01-01
An analytical method for estimation of polypeptide-k using UV spectrophotometry has been developed and validated for bulk as well as tablet dosage form. The developed method was validated for linearity, precision, accuracy, specificity, robustness, detection, and quantitation limits. The method has shown good linearity over the range from 100.0 to 300.0 μg/ml with a correlation coefficient of 0.9943. The percentage recovery of 99.88% showed that the method was highly accurate. The precision demonstrated relative standard deviation of less than 2.0%. The LOD and LOQ of the method were found to be 4.4 and 13.33, respectively. The study established that the proposed method is reliable, specific, reproducible, and cost-effective for the determination of polypeptide-k.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yokoyama, Yoko; Shimizu, Akira; Okada, Etsuko
Highlights: Black-Right-Pointing-Pointer We developed new method to rapidly identify COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer New PCR method using a single primer pair detected COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer This is the first report of DFSP with a novel COL1A1 breakpoint in exon 5. -- Abstract: The detection of fusion transcripts of the collagen type 1{alpha}1 (COL1A1) and platelet-derived growth factor-BB (PDGFB) genes by genetic analysis has recognized as a reliable and valuable molecular tool for the diagnosis of dermatofibrosarcoma protuberans (DFSP). To detect the COL1A1-PDGFB fusion, almost previous reports performed reverse transcription polymerase chain reaction (RT-PCR) using multiplex forward primersmore » from COL1A1. However, it has possible technical difficulties with respect to the handling of multiple primers and reagents in the procedure. The objective of this study is to establish a rapid, easy, and efficient one-step method of PCR using only a single primer pair to detect the fusion transcripts of the COL1A1 and PDGFB in DFSP. To validate new method, we compared the results of RT-PCR in five patients of DFSP between the previous method using multiplex primers and our established one-step RT-PCR using a single primer pair. In all cases of DFSP, the COL1A1-PDGFB fusion was detected by both previous method and newly established one-step PCR. Importantly, we detected a novel COL1A1 breakpoint in exon 5. The newly developed method is valuable to rapidly identify COL1A1-PDGFB fusion transcripts in DFSP.« less
O'Connor, S; McCaffrey, N; Whyte, E; Moran, K
2016-07-01
To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.
[Study on quality standard of Mucuna pruriens var. utilis].
Wu, Shi-Hong; Jiang, Wei-Zhe; Lv, Li; Wu, Ling-Ling; Lv, Cong; Shi, Xiao-Xia; Su, Gui-Liang
2009-03-01
To provide scientific basis for the utilization and development of Mucuna pruriens var. utilis by establishing its quality control standard. The bioactive constituents were analyzed by TLC and HPLC. Moisture, ash and the extracts of Mucuna pruriens var. utilis were all determined. The TLC spots of levodopa had similar color with the control group at the same position. The results of HPLC quantitative analysis showed that the linear range of levodopa was 26.45 to approximately 132.25 microg/mL, r = 0.9992, and the average recovery rate was 103.8%, RSD = 1.85%. This method is convenient, accurate, reliable with good reproducibility, so it can be used to establish quality standard for the medicinal material.
A new method of radio frequency links by coplanar coils for implantable medical devices.
Xue, L; Hao, H W; Li, L; Ma, B Z
2005-01-01
A new method based on coplanar coils for the design of radio frequency links has been developed, to realize the communication between the programming wand and the implantable medical devices with shielding container simply and reliably. With the analysis of electronic and magnetic field theory, the communication model has been established and simulated, and the circuit has been designed and tested. The experimental results are consistent with the simulation fairly well. The voltage transfer ratio of the typical circuit with present parameters can reach as high as 0.02, which can fulfill the requirements of communication.
NASA Astrophysics Data System (ADS)
Sheikholeslami, Mohsen; Azimi, Mohammadreza; Domiri Ganji, Davood
2015-07-01
In this study, we propose a reliable algorithm to develop an analytical solution for the problem of laminar steady magnetohydrodymanics (MHD) nanofluid flow in a semi-permeable channel using the differential transformation method (DTM). The working fluid is water with copper nanoparticles. The effects of Hartmann number and Reynolds number on velocity profiles have been also considered for various numerical cases. The effective thermal conductivity and viscosity of nanofluid are calculated by the Maxwell and Brinkman models, respectively. A close agreement between the obtained solution and some well-known results has been established.
Palmer, Janice L.; Coats, Mary A.; Roe, Catherine M.; Hanko, Shelly M.; Xiong, Chengjie; Morris, John C.
2010-01-01
Aim This paper is a report of a study to establish the inter-rater reliability of advanced practice nurse and neurologist neurological assessments which included ratings with the Unified Parkinson’s Disease Rating Scale-Motor Exam. Background Around the world, advanced practice nurses are performing tasks once completed by only physicians. To promote consumer and provider confidence, it is important to establish that nurse and physician ratings using assessment tools are similar. In addition in research settings, when different raters are used, establishment of inter-rater reliability for study assessments is needed. Method Advanced practice nurses and neurologists independently recorded findings on neurological examinations of 46 participants in a study conducted between August 2007 and January 2008. An intraclass correlation coefficient was calculated to estimate overall agreement between the nurse and neurologist ratings. Agreement for individual items measured on a dichotomous scale was assessed by calculating Cohen’s kappa. Results There was substantial agreement between advanced practice nurses and neurologists on the mean Unified Parkinson’s Disease Rating Scale-Motor Exam ratings (intraclass correlation coefficient = 0.65) and the U.S. National Alzheimer’s Coordinating Center Uniform Data Set neurological examination ratings of unremarkable findings (kappa = 0.74) and of gait disorder (kappa = 0.73). Moderate agreement (kappa = 0.53) was reached for the rating of whether all Unified Parkinson’s Disease Rating Scale-Motor Exam items were normal. Conclusion These findings are consistent with studies of the inter-rater agreement of the Unified Parkinson’s Disease Rating Scale-Motor Exam and support the conduct of neurological assessments by advanced practice nurses. PMID:20546368
Jiang, Guofei; Lu, Tulin; Mao, Chunqin; Su, Tao; Sun, Xiaomin
2010-11-01
To establish a HPLC method for determination of 4 components in different varieties of vinegar backed Rhizoma Curcuma. The method was established by using an Elite Hypersil ODS2 column (4.6 mm x 250 mm, 5 microm). The mobile phase comprising acetonitrile (A) and water (B) was used to elute the targets in gradient elution mode. Flow rate and detection wavelength were set at 1 mL x min(-1) and 214 nm, respectively. The column temperature was 25 degrees C and the injection volume was 10 microL. All calibration curves showed good linearity with r > 0.999 5. Recoveries measured at three concentrations were in the range of 97.27% - 99.27% with RSD < 3%. The validated method is simple, reliable, and successfully applied to determine the contents of the selected compounds in vinegar backed Rhizoma Curcuma. The results of the determination showed that contents of the four components in vinegar backed Curcuma wenyujin were relatively high.
Autonomous learning in gesture recognition by using lobe component analysis
NASA Astrophysics Data System (ADS)
Lu, Jian; Weng, Juyang
2007-02-01
Gesture recognition is a new human-machine interface method implemented by pattern recognition(PR).In order to assure robot safety when gesture is used in robot control, it is required to implement the interface reliably and accurately. Similar with other PR applications, 1) feature selection (or model establishment) and 2) training from samples, affect the performance of gesture recognition largely. For 1), a simple model with 6 feature points at shoulders, elbows, and hands, is established. The gestures to be recognized are restricted to still arm gestures, and the movement of arms is not considered. These restrictions are to reduce the misrecognition, but are not so unreasonable. For 2), a new biological network method, called lobe component analysis(LCA), is used in unsupervised learning. Lobe components, corresponding to high-concentrations in probability of the neuronal input, are orientation selective cells follow Hebbian rule and lateral inhibition. Due to the advantage of LCA method for balanced learning between global and local features, large amount of samples can be used in learning efficiently.
Wang, Yutang; Liu, Yuanyuan; Xiao, Chunxia; Liu, Laping; Hao, Miao; Wang, Jianguo; Liu, Xuebo
2014-06-01
This study established a new method for quantitative and qualitative determination of certain components in black rice wine, a traditional Chinese brewed wine. Specifically, we combined solid-phase extraction and high-performance liquid chromatography (HPLC) with triple quadrupole mass spectrometry (MS/MS) to determine 8 phenolic acids, 3 flavonols, and 4 anthocyanins in black rice wine. First, we clean samples with OASIS HLB cartridges and optimized extraction parameters. Next, we performed separation on a SHIM-PACK XR-ODS column (I.D. 3.0 mm × 75 mm, 2.2 μm particle size) with a gradient elution of 50% aqueous acetonitrile (V/V) and water, both containing 0.2% formic acid. We used multiple-reaction monitoring scanning for quantification, with switching electrospray ion source polarity between positive and negative modes in a single chromatographic run. We detected 15 phenolic compounds properly within 38 min under optimized conditions. Limits of detection ranged from 0.008 to 0.030 mg/L, and average recoveries ranged from 60.8 to 103.1% with relative standard deviation ≤8.6%. We validated the method and found it to be sensitive and reliable for quantifying phenolic compounds in rice wine matrices. This study developed a new, reliable HPLC-MS/MS method for simultaneous determination of 15 bioactive components in black rice wine. This method was validated and found to be sensitive and reliable for quantifying phenolic compounds in rice wine. © 2014 Institute of Food Technologists®
Whalley, H C; Kestelman, J N; Rimmington, J E; Kelso, A; Abukmeil, S S; Best, J J; Johnstone, E C; Lawrie, S M
1999-07-30
The Edinburgh High Risk Project is a longitudinal study of brain structure (and function) in subjects at high risk of developing schizophrenia in the next 5-10 years for genetic reasons. In this article we describe the methods of volumetric analysis of structural magnetic resonance images used in the study. We also consider potential sources of error in these methods: the validity of our image analysis techniques; inter- and intra-rater reliability; possible positional variation; and thresholding criteria used in separating brain from cerebro-spinal fluid (CSF). Investigation with a phantom test object (of similar imaging characteristics to the brain) provided evidence for the validity of our image acquisition and analysis techniques. Both inter- and intra-rater reliability were found to be good in whole brain measures but less so for smaller regions. There were no statistically significant differences in positioning across the three study groups (patients with schizophrenia, high risk subjects and normal volunteers). A new technique for thresholding MRI scans longitudinally is described (the 'rescale' method) and compared with our established method (thresholding by eye). Few differences between the two techniques were seen at 3- and 6-month follow-up. These findings demonstrate the validity and reliability of the structural MRI analysis techniques used in the Edinburgh High Risk Project, and highlight methodological issues of general concern in cross-sectional and longitudinal studies of brain structure in healthy control subjects and neuropsychiatric populations.
Reliability of a New Radiographic Classification for Developmental Dysplasia of the Hip.
Narayanan, Unni; Mulpuri, Kishore; Sankar, Wudbhav N; Clarke, Nicholas M P; Hosalkar, Harish; Price, Charles T
2015-01-01
Existing radiographic classification schemes (eg, Tönnis criteria) for DDH quantify the severity of disease based on the position of the ossific nucleus relative to Hilgenreiner's and Perkin's lines. By definition, this method requires the presence of an ossification centre, which can be delayed in appearance and eccentric in location within the femoral head. A new radiographic classification system has been developed by the International Hip Dysplasia Institute (IHDI), which uses the mid-point of the proximal femoral metaphysis as a reference landmark, and can therefore be applied to children of all ages. The purpose of this study was to compare the reliability of this new method with that of Tönnis, as the first step in establishing its validity and clinical utility. Twenty standardized anteroposterior pelvic radiographs of children with untreated DDH were selected purposefully to capture the spectrum of age (range, 3 to 32 mo) at presentation and disease severity. Each of the hips was classified separately by the IHDI and Tönnis methods by 6 experienced pediatric orthopaedists from the United States, Canada, Mexico, United Kingdom, and by 2 orthopaedic senior residents. The inter-rater reliability was tested using the Intra Class Correlation coefficient (ICC) to measure concordance between raters. All 40 hips were classifiable by the IHDI method by all raters. Ten of the 40 hips could not be classified by the Tönnis method because of the absence of the ossific nucleus on one or both sides. The ICC (95% confidence interval) for the IHDI method for all raters was 0.90 (0.83-0.95) and 0.95 (0.91-0.98) for the right and left hips, respectively. The corresponding ICCs for the Tönnis method were 0.63 (0.46-0.80) and 0.60 (0.43-0.78), respectively. There was no significant difference between the ICCs of the 6 experts and 2 trainees. The IHDI method of classification has excellent inter-rater reliability, both among experts and novices, and is more widely applicable than the Tönnis method as it can be applied even when the ossification centre is absent. Level II (diagnostic).
Potential of DNA barcoding for detecting quarantine fungi.
Gao, Ruifang; Zhang, Guiming
2013-11-01
The detection of live quarantine pathogenic fungi plays an important role in guaranteeing regional biological safety. DNA barcoding, an emerging species identification technology, holds promise for the reliable, quick, and accurate detection of quarantine fungi. International standards for phytosanitary guidelines are urgently needed. The varieties of quarantine fungi listed for seven countries/regions, the currently applied detection methods, and the status of DNA barcoding for detecting quarantine fungi are summarized in this study. Two approaches have been proposed to apply DNA barcoding to fungal quarantine procedures: (i) to verify the reliability of known internal transcribed spacer (ITS)/cytochrome c oxidase subunit I (COI) data for use as barcodes, and (ii) to determine other barcodes for species that cannot be identified by ITS/COI. As a unique, standardizable, and universal species identification tool, DNA barcoding offers great potential for integrating detection methods used in various countries/regions and establishing international detection standards based on accepted DNA barcodes. Through international collaboration, interstate disputes can be eased and many problems related to routine quarantine detection methods can be solved for global trade.
Christians, Stefan; van Treel, Nadine Denise; Bieniara, Gabriele; Eulig-Wien, Annika; Hanschmann, Kay-Martin; Giess, Siegfried
2016-07-01
Capillary zone electrophoresis (CZE) provides an alternative means of separating native proteins on the basis of their inherent electrophoretic mobilities. The major advantage of CZE is the quantification by UV detection, circumventing the drawbacks of staining and densitometry in the case of gel electrophoresis methods. The data of this validation study showed that CZE is a reliable assay for the determination of protein composition in therapeutic preparations of human albumin and human polyclonal immunoglobulins. Data obtained by CZE are in line with "historical" data obtained by the compendial method, provided that peak integration is performed without time correction. The focus here was to establish a rapid and reliable test to substitute the current gel based zone electrophoresis techniques for the control of protein composition of human immunoglobulins or albumins in the European Pharmacopoeia. We believe that the more advanced and modern CZE method described here is a very good alternative to the procedures currently described in the relevant monographs. Copyright © 2016 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Smith, Richard; Zaitoun, Halla; Coxon, Tom; Karmo, Mayada; Kaur, Gurpreet; Townsend, Grant; Harris, Edward F.; Brook, Alan
2009-01-01
Aims In studying aetiological interactions of genetic, epigenetic and environmental factors in normal and abnormal developments of the dentition, methods of measurement have often been limited to maximum mesio-distal and bucco-lingual crown diameters, obtained with hand-held calipers. While this approach has led to many important findings, there are potentially many other informative measurements that can be made to describe dental crown morphology. Advances in digital imaging and computer technology now offer the opportunity to define and measure new dental phenotypes in 3-D that have the potential to provide better anatomical discrimination and clearer insights into the underlying biological processes in dental development. Over recent years, image analysis in 2-D has proved to be a valuable addition to hand-measurement methods but a reliable and rapid 3-D method would increase greatly the morphological information obtainable from natural teeth and dental models. Additional measurements such as crown heights, surface contours, actual surface perimeters and areas, and tooth volumes would maximise our ability to discriminate between samples and to explore more deeply genetic and environmental contributions to observed variation. The research objectives were to investigate the limitations of existing methodologies and to develop and validate new methods for obtaining true 3-D measurements, including curvatures and volumes, in order to enhance discrimination to allow increased differentiation in studies of dental morphology and development. The validity of a new methodology for the 3-D measurement of teeth is compared against an established 2-D system. The intra- and inter-observer reliability of some additional measurements, made possible with a 3-D approach, are also tested. Methods and results From each of 20 study models, the permanent upper right lateral and upper left central incisors were separated and imaged independently by two operators using 2-D image analysis and a 3-D image analysis system. The mesio-distal (MD), labio-lingual (LL) and inciso-gingival (IG) dimensions were recorded using our 2-D system and the same projected variables were also recorded using a newly developed 3-D system for comparison. Values of Pearson's correlation coefficient between measurements obtained using the two techniques were significant at the 0.01 probability level for variables mesio-distal and incisal-gingival with labio-lingual significant at the 0.05 level for the upper left side only, confirming their comparability. For both 2-D and 3-D systems the intra- and inter-operator reliability was substantial or excellent for variables mesio-distal, labio-lingual, incisal-gingival actual and projected and actual surface area. The reliability was good for inter-operator reliability measurement of the labio-lingual dimension using 3-D. Conclusions We have developed a new 3-D laser scanning system that enables additional dental phenotypes to be defined. It has been validated against an established 2-D system and shown to provide measurements with excellent reliability, both within and between operators. This new approach provides exciting possibilities for exploring normal and abnormal variations in dental morphology and development applicable to research on genetic and environmental factors. PMID:18644585
Validity of a Simple Method for Measuring Force-Velocity-Power Profile in Countermovement Jump.
Jiménez-Reyes, Pedro; Samozino, Pierre; Pareja-Blanco, Fernando; Conceição, Filipe; Cuadrado-Peñafiel, Víctor; González-Badillo, Juan José; Morin, Jean-Benoît
2017-01-01
To analyze the reliability and validity of a simple computation method to evaluate force (F), velocity (v), and power (P) output during a countermovement jump (CMJ) suitable for use in field conditions and to verify the validity of this computation method to compute the CMJ force-velocity (F-v) profile (including unloaded and loaded jumps) in trained athletes. Sixteen high-level male sprinters and jumpers performed maximal CMJs under 6 different load conditions (0-87 kg). A force plate sampling at 1000 Hz was used to record vertical ground-reaction force and derive vertical-displacement data during CMJ trials. For each condition, mean F, v, and P of the push-off phase were determined from both force-plate data (reference method) and simple computation measures based on body mass, jump height (from flight time), and push-off distance and used to establish the linear F-v relationship for each individual. Mean absolute bias values were 0.9% (± 1.6%), 4.7% (± 6.2%), 3.7% (± 4.8%), and 5% (± 6.8%) for F, v, P, and slope of the F-v relationship (S Fv ), respectively. Both methods showed high correlations for F-v-profile-related variables (r = .985-.991). Finally, all variables computed from the simple method showed high reliability, with ICC >.980 and CV <1.0%. These results suggest that the simple method presented here is valid and reliable for computing CMJ force, velocity, power, and F-v profiles in athletes and could be used in practice under field conditions when body mass, push-off distance, and jump height are known.
A simple and reliable multi-gene transformation method for switchgrass.
Ogawa, Yoichi; Shirakawa, Makoto; Koumoto, Yasuko; Honda, Masaho; Asami, Yuki; Kondo, Yasuhiro; Hara-Nishimura, Ikuko
2014-07-01
A simple and reliable Agrobacterium -mediated transformation method was developed for switchgrass. Using this method, many transgenic plants carrying multiple genes-of-interest could be produced without untransformed escape. Switchgrass (Panicum virgatum L.) is a promising biomass crop for bioenergy. To obtain transgenic switchgrass plants carrying a multi-gene trait in a simple manner, an Agrobacterium-mediated transformation method was established by constructing a Gateway-based binary vector, optimizing transformation conditions and developing a novel selection method. A MultiRound Gateway-compatible destination binary vector carrying the bar selectable marker gene, pHKGB110, was constructed to introduce multiple genes of interest in a single transformation. Two reporter gene expression cassettes, GUSPlus and gfp, were constructed independently on two entry vectors and then introduced into a single T-DNA region of pHKGB110 via sequential LR reactions. Agrobacterium tumefaciens EHA101 carrying the resultant binary vector pHKGB112 and caryopsis-derived compact embryogenic calli were used for transformation experiments. Prolonged cocultivation for 7 days followed by cultivation on media containing meropenem improved transformation efficiency without overgrowth of Agrobacterium, which was, however, not inhibited by cefotaxime or Timentin. In addition, untransformed escape shoots were completely eliminated during the rooting stage by direct dipping the putatively transformed shoots into the herbicide Basta solution for a few seconds, designated as the 'herbicide dipping method'. It was also demonstrated that more than 90 % of the bar-positive transformants carried both reporters delivered from pHKGB112. This simple and reliable transformation method, which incorporates a new selection technique and the use of a MultiRound Gateway-based binary vector, would be suitable for producing a large number of transgenic lines carrying multiple genes.
Fuentes Fernández, Ramón; Carter, Pablo; Muñoz, Sergio; Silva, Héctor; Oporto Venegas, Gonzalo Hernán; Cantin, Mario; Ottone, Nicolás Ernesto
2016-04-01
Temporomandibular joint disorders (TMJDs) are caused by several factors such as anatomical, neuromuscular and psychological alterations. A relationship has been established between TMJDs and postural alterations, a type of anatomical alteration. An anterior position of the head requires hyperactivity of the posterior neck region and shoulder muscles to prevent the head from falling forward. This compensatory muscular function may cause fatigue, discomfort and trigger point activation. To our knowledge, a method for assessing human postural attitude in more than one plane has not been reported. Thus, the aim of this study was to design a methodology to measure the external human postural attitude in frontal and sagittal planes, with proper validity and reliability analyses. The variable postures of 78 subjects (36 men, 42 women; age 18-24 years) were evaluated. The postural attitudes of the subjects were measured in the frontal and sagittal planes, using an acromiopelvimeter, grid panel and Fox plane. The method we designed for measuring postural attitudes had adequate reliability and validity, both qualitatively and quantitatively, based on Cohen's Kappa coefficient (> 0.87) and Pearson's correlation coefficient (r = 0.824, > 80%). This method exhibits adequate metrical properties and can therefore be used in further research on the association of human body posture with skeletal types and TMJDs. Copyright © Singapore Medical Association.
Active Control of Forebody Vortices on a schematic Aircraft Model
2001-06-01
coeffi- The system comprised two miniature soleniod on/off cient (C, = 0.0013) was sufficient to reliably switch pneumatic valves to control the flow to...method and time-average rolling moment, pitching moment, and normal force. Nomenclature T duration a valve is open during the alternating blow- b wing...reasonably high reduced frequency of the valves , and the tubes that delivered the air to the (* =0.16). Having established that the forebody vor- nozzles
Courses of Action to Optimize Heavy Bearings Cages
NASA Astrophysics Data System (ADS)
Szekely, V. G.
2016-11-01
The global expansion in the industrial, economically and technological context determines the need to develop products, technologies, processes and methods which ensure increased performance, lower manufacturing costs and synchronization of the main costs reported to the elementary values which correspond to utilization”. The development trend of the heavy bearing industry and the wide use of bearings determines the necessity of choosing the most appropriate material for a given application in order to meet the cumulative requirements of durability, reliability, strength, etc. Evaluation of commonly known or new materials represents a fundamental criterion, in order to choose the materials based on the cost, machinability and the technological process. In order to ensure the most effective basis for the decision, regarding the heavy bearing cage, in the first stage the functions of the product are established and in a further step a comparative analysis of the materials is made in order to establish the best materials which satisfy the product functions. The decision for selecting the most appropriate material is based largely on the overlapping of the material costs and manufacturing process during which the half-finished material becomes a finished product. The study is orientated towards a creative approach, especially towards innovation and reengineering by using specific techniques and methods applied in inventics. The main target is to find new efficient and reliable constructive and/or technological solutions which are consistent with the concept of sustainable development.
Statistical summaries of fatigue data for design purposes
NASA Technical Reports Server (NTRS)
Wirsching, P. H.
1983-01-01
Two methods are discussed for constructing a design curve on the safe side of fatigue data. Both the tolerance interval and equivalent prediction interval (EPI) concepts provide such a curve while accounting for both the distribution of the estimators in small samples and the data scatter. The EPI is also useful as a mechanism for providing necessary statistics on S-N data for a full reliability analysis which includes uncertainty in all fatigue design factors. Examples of statistical analyses of the general strain life relationship are presented. The tolerance limit and EPI techniques for defining a design curve are demonstrated. Examples usng WASPALOY B and RQC-100 data demonstrate that a reliability model could be constructed by considering the fatigue strength and fatigue ductility coefficients as two independent random variables. A technique given for establishing the fatigue strength for high cycle lives relies on an extrapolation technique and also accounts for "runners." A reliability model or design value can be specified.
A Tool for Measuring Active Learning in the Classroom
Devlin, John W.; Kirwin, Jennifer L.; Qualters, Donna M.
2007-01-01
Objectives To develop a valid and reliable active-learning inventory tool for use in large classrooms and compare faculty perceptions of active-learning using the Active-Learning Inventory Tool. Methods The Active-Learning Inventory Tool was developed using published literature and validated by national experts in educational research. Reliability was established by trained faculty members who used the Active-Learning Inventory Tool to observe 9 pharmacy lectures. Instructors were then interviewed to elicit perceptions regarding active learning and asked to share their perceptions. Results Per lecture, 13 (range: 4-34) episodes of active learning encompassing 3 (range: 2-5) different types of active learning occurred over 2.2 minutes (0.6-16) per episode. Both interobserver (≥87%) and observer-instructor agreement (≥68%) were high for these outcomes. Conclusions The Active-Learning Inventory Tool is a valid and reliable tool to measure active learning in the classroom. Future studies are needed to determine the impact of the Active-Learning Inventory Tool on teaching and its usefulness in other disciplines. PMID:17998982
Methodology for Software Reliability Prediction. Volume 1.
1987-11-01
SPACECRAFT 0 MANNED SPACECRAFT B ATCH SYSTEM AIRBORNE AVIONICS 0 UNMANNED EVENT C014TROL a REAL TIME CLOSED 0 UNMANNED SPACECRAFT LOOP OPERATINS SPACECRAFT...software reliability. A Software Reliability Measurement Framework was established which spans the life cycle of a software system and includes the...specification, prediction, estimation, and assessment of software reliability. Data from 59 systems , representing over 5 million lines of code, were
Universal first-order reliability concept applied to semistatic structures
NASA Technical Reports Server (NTRS)
Verderaime, V.
1994-01-01
A reliability design concept was developed for semistatic structures which combines the prevailing deterministic method with the first-order reliability method. The proposed method surmounts deterministic deficiencies in providing uniformly reliable structures and improved safety audits. It supports risk analyses and reliability selection criterion. The method provides a reliability design factor derived from the reliability criterion which is analogous to the current safety factor for sizing structures and verifying reliability response. The universal first-order reliability method should also be applicable for air and surface vehicles semistatic structures.
Universal first-order reliability concept applied to semistatic structures
NASA Astrophysics Data System (ADS)
Verderaime, V.
1994-07-01
A reliability design concept was developed for semistatic structures which combines the prevailing deterministic method with the first-order reliability method. The proposed method surmounts deterministic deficiencies in providing uniformly reliable structures and improved safety audits. It supports risk analyses and reliability selection criterion. The method provides a reliability design factor derived from the reliability criterion which is analogous to the current safety factor for sizing structures and verifying reliability response. The universal first-order reliability method should also be applicable for air and surface vehicles semistatic structures.
Reliability analysis of a robotic system using hybridized technique
NASA Astrophysics Data System (ADS)
Kumar, Naveen; Komal; Lather, J. S.
2017-09-01
In this manuscript, the reliability of a robotic system has been analyzed using the available data (containing vagueness, uncertainty, etc). Quantification of involved uncertainties is done through data fuzzification using triangular fuzzy numbers with known spreads as suggested by system experts. With fuzzified data, if the existing fuzzy lambda-tau (FLT) technique is employed, then the computed reliability parameters have wide range of predictions. Therefore, decision-maker cannot suggest any specific and influential managerial strategy to prevent unexpected failures and consequently to improve complex system performance. To overcome this problem, the present study utilizes a hybridized technique. With this technique, fuzzy set theory is utilized to quantify uncertainties, fault tree is utilized for the system modeling, lambda-tau method is utilized to formulate mathematical expressions for failure/repair rates of the system, and genetic algorithm is utilized to solve established nonlinear programming problem. Different reliability parameters of a robotic system are computed and the results are compared with the existing technique. The components of the robotic system follow exponential distribution, i.e., constant. Sensitivity analysis is also performed and impact on system mean time between failures (MTBF) is addressed by varying other reliability parameters. Based on analysis some influential suggestions are given to improve the system performance.
Development of X-ray computed tomography inspection facility for the H-II solid rocket boosters
NASA Astrophysics Data System (ADS)
Sasaki, M.; Fujita, T.; Fukushima, Y.; Shimizu, M.; Itoh, S.; Satoh, A.; Miyamoto, H.
The National Space Development Agency of Japan (NASDA) initiated the development of an X-ray computed tomography (CT) equipment for the H-II solid rocket boosters (SRBs) in 1987 for the purpose of minimizing inspection time and achieving high cost-effectiveness. The CT facility has been completed in Jan. 1991 in Tanegashima Space Center for the inspection of the SRBs transported from the manufacturer's factory to the launch site. It was first applied to the qualification model SRB from Feb. to Apr. in 1991. Through the CT inspection of the SRB, it has been confirmed that inspection time decreased significantly compared with the X-ray radiography method and that even an unskilled inspector could find various defects. As a result, the establishment of a new reliable inspection method for the SRB has been verified. In this paper, the following are discussed: (1) the defect detectability of the CT equipment using a dummy SRB with various artificial defects, (2) the performance comparison between the CT method and the X-ray radiography method, (3) the reliability of the CT equipment, and (4) the radiation shield design of the nondestructive test building.
2011-01-01
Background Since stress is hypothesized to play a role in the etiology of obesity during adolescence, research on associations between adolescent stress and obesity-related parameters and behaviours is essential. Due to lack of a well-established recent stress checklist for use in European adolescents, the study investigated the reliability and validity of the Adolescent Stress Questionnaire (ASQ) for assessing perceived stress in European adolescents. Methods The ASQ was translated into the languages of the participating cities (Ghent, Stockholm, Vienna, Zaragoza, Pecs and Athens) and was implemented within the HELENA cross-sectional study. A total of 1140 European adolescents provided a valid ASQ, comprising 10 component scales, used for internal reliability (Cronbach α) and construct validity (confirmatory factor analysis or CFA). Contributions of socio-demographic (gender, age, pubertal stage, socio-economic status) characteristics to the ASQ score variances were investigated. Two-hundred adolescents also provided valid saliva samples for cortisol analysis to compare with the ASQ scores (criterion validity). Test-retest reliability was investigated using two ASQ assessments from 37 adolescents. Results Cronbach α-values of the ASQ scales (0.57 to 0.88) demonstrated a moderate internal reliability of the ASQ, and intraclass correlation coefficients (0.45 to 0.84) established an insufficient test-retest reliability of the ASQ. The adolescents' gender (girls had higher stress scores than boys) and pubertal stage (those in a post-pubertal development had higher stress scores than others) significantly contributed to the variance in ASQ scores, while their age and socio-economic status did not. CFA results showed that the original scale construct fitted moderately with the data in our European adolescent population. Only in boys, four out of 10 ASQ scale scores were a significant positive predictor for baseline wake-up salivary cortisol, suggesting a rather poor criterion validity of the ASQ, especially in girls. Conclusions In our European adolescent sample, the ASQ had an acceptable internal reliability and construct validity and the adolescents' gender and pubertal stage systematically contributed to the ASQ variance, but its test-retest reliability and criterion validity were rather poor. Overall, the utility of the ASQ for assessing perceived stress in adolescents across Europe is uncertain and some aspects require further examination. PMID:21943341
THE INTRA- AND INTER-RATER RELIABILITY OF THE SOCCER INJURY MOVEMENT SCREEN (SIMS)
aus der Fünten, Karen; Govus, Andrew; Julian, Ross; Schimpchen, Jan; Meyer, Tim
2017-01-01
Background/purpose The growing volume of movement screening research reveals a belief among practitioners and researchers alike that movement quality may have an association with injury risk. However, existing movement screening tools have not considered the sport-specific movement and injury patterns relevant to soccer. The present study introduces the Soccer Injury Movement Screen (SIMS), which has been designed specifically for use within soccer. Furthermore, the purpose of the present study was to assess the intra- and inter-rater reliability of the SIMS and determine its suitability for use in further research. Methods The study utilized a test-retest design to discern reliablility. Twenty-five (11 males, 14 females) healthy, recreationally active university students (age 25.5 ± 4.0 years, height 171 ± 9 cm, weight 64.7 ± 12.6 kg) agreed to participate. The SIMS contains five sub-tests: the anterior reach, single-leg deadlift, in-line lunge, single-leg hop for distance and tuck jump. Each movement was scored out of 10 points and summed to produce a composite score out of 50. The anterior reach and single-leg hop for distance were scored in real-time while the remaining tests were filmed and scored retrospectively. Three raters conducted the SIMS with each participant on three occasions separated by an average of three and a half days (minimum one day, maximum seven days). Rater 1 re-scored the filmed movements for all participants on all occasions six months later to establish the ‘pure’ intra-rater (intra-occasion) reliability for those movements. Results Intraclass correlation coefficient (ICC) values for intra- and inter-rater composite score reliability ranged from 0.66-0.72 and 0.79-0.86 respectively. Weighted kappa values representing the intra- and inter-rater reliability of the individual sub-tests ranged from 0.35-0.91 indicating fair to almost perfect agreement. Conclusions Establishing the reliability of the SIMS is a prerequisite for further research seeking to investigate the relationship between test score and subsequent injury. The present results indicate acceptable reliability for this purpose; however, room for further development of the intra-rater reliability exists for some of the individual sub-tests. Level of evidence 2b PMID:28217416
Reliability and Validity of Dual-Task Mobility Assessments in People with Chronic Stroke
Yang, Lei; He, Chengqi; Pang, Marco Yiu Chung
2016-01-01
Background The ability to perform a cognitive task while walking simultaneously (dual-tasking) is important in real life. However, the psychometric properties of dual-task walking tests have not been well established in stroke. Objective To assess the test-retest reliability, concurrent and known-groups validity of various dual-task walking tests in people with chronic stroke. Design Observational measurement study with a test-retest design. Methods Eighty-eight individuals with chronic stroke participated. The testing protocol involved four walking tasks (walking forward at self-selected and maximal speed, walking backward at self-selected speed, and crossing over obstacles) performed simultaneously with each of the three attention-demanding tasks (verbal fluency, serial 3 subtractions or carrying a cup of water). For each dual-task condition, the time taken to complete the walking task, the correct response rate (CRR) of the cognitive task, and the dual-task effect (DTE) for the walking time and CRR were calculated. Forty-six of the participants were tested twice within 3–4 days to establish test-retest reliability. Results The walking time in various dual-task assessments demonstrated good to excellent reliability [Intraclass correlation coefficient (ICC2,1) = 0.70–0.93; relative minimal detectable change at 95% confidence level (MDC95%) = 29%-45%]. The reliability of the CRR (ICC2,1 = 0.58–0.81) and the DTE in walking time (ICC2,1 = 0.11–0.80) was more varied. The reliability of the DTE in CRR (ICC2,1 = -0.31–0.40) was poor to fair. The walking time and CRR obtained in various dual-task walking tests were moderately to strongly correlated with those of the dual-task Timed-up-and-Go test, thus demonstrating good concurrent validity. None of the tests could discriminate fallers (those who had sustained at least one fall in the past year) from non-fallers. Limitation The results are generalizable to community-dwelling individuals with chronic stroke only. Conclusions The walking time derived from the various dual-task assessments generally demonstrated good to excellent reliability, making them potentially useful in clinical practice and future research endeavors. However, the usefulness of these measurements in predicting falls needs to be further explored. Relatively low reliability was shown in the cognitive outcomes and DTE, which may not be preferred measurements for assessing dual-task performance. PMID:26808662
A simple behavioral test for locomotor function after brain injury in mice.
Tabuse, Masanao; Yaguchi, Masae; Ohta, Shigeki; Kawase, Takeshi; Toda, Masahiro
2010-11-01
To establish a simple and reliable test for assessing locomotor function in mice with brain injury, we developed a new method, the rotarod slip test, in which the number of slips of the paralytic hind limb from a rotarod is counted. Brain injuries of different severity were created in adult C57BL/6 mice, by inflicting 1-point, 2-point and 4-point cryo-injuries. These mice were subjected to the rotarod slip test, the accelerating rotarod test and the elevated body swing test (EBST). Histological analyses were performed to assess the severity of the brain damage. Significant and consistent correlations between test scores and severity were observed for the rotarod slip test and the EBST. Only the rotarod slip test detected the mild hindlimb paresis in the acute and sub-acute phase after injury. Our results suggest that the rotarod slip test is the most sensitive and reliable method for assessing locomotor function after brain damage in mice. Copyright © 2010 Elsevier Ltd. All rights reserved.
A novel reliable method of DNA extraction from olive oil suitable for molecular traceability.
Raieta, Katia; Muccillo, Livio; Colantuoni, Vittorio
2015-04-01
Extra virgin olive oil production has a worldwide economic impact. The use of this brand, however, is of great concern to Institutions and private industries because of the increasing number of fraud and adulteration attempts to the market products. Here, we present a novel, reliable and not expensive method for extracting the DNA from commercial virgin and extra virgin olive oils. The DNA is stable overtime and amenable for molecular analyses; in fact, by carrying out simple sequence repeats (SSRs) markers analysis, we characterise the genetic profile of monovarietal olive oils. By comparing the oil-derived pattern with that of the corresponding tree, we can unambiguously identify four cultivars from Samnium, a region of Southern Italy, and distinguish them from reference and more widely used varieties. Through a parentage statistical analysis, we also identify the putative pollinators, establishing an unprecedented and powerful tool for olive oil traceability. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chen, Lin-Wei; Wang, Qin; Qin, Kun-Ming; Wang, Xiao-Li; Wang, Bin; Chen, Dan-Ni; Cai, Bao-Chang; Cai, Ting
2016-02-01
The present study was designed to develop and validate a sensitive and reliable ultra high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UPLC-QTOF/MS) method to separate and identify the chemical constituents of Qixue Shuangbu Tincture (QXSBT), a classic traditional Chinese medicine (TCM) prescription. Under the optimized UPLC and QTOF/MS conditions, 56 components in QXSBT, including chalcones, triterpenoids, protopanaxatriol, flavones and flavanones were identified and tentatively characterized within a running time of 42 min. The components were identified by comparing the retention times, accurate mass, and mass spectrometric fragmentation characteristic ions, and matching empirical molecular formula with that of the published compounds. In conclusion, the established UPLC-QTOF/MS method was reliable for a rapid identification of complicated components in the TCM prescriptions. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
The first case study of 230Th/U and 14C dating of mid-valdai organic deposits
NASA Astrophysics Data System (ADS)
Maksimov, F. E.; Kuznetsov, V. Yu.; Zaretskaya, N. E.; Subetto, D. A.; Shebotinov, V. V.; Zherebtsov, I. E.; Levchenko, S. B.; Kuznetsov, D. D.; Larsen, E.; Lysö, A.; Jensen, M.
2011-05-01
From the viewpoint of precision and reliability of radioisotopic dating, deposits whose quantitative age can be determined through several methods of geochronometry are of special interest. The mutually conforming finite 14C and 230Th/U dates of buried Neopleistocene organic deposits, taken from the Tolokonka section by the North Dvina River (100 km downstream from the city of Kotlas), have been obtained for the first time in Russia. The stratigraphical reference of these results to those obtained via the optically induced luminescence for upper and lower bedding layers has been established. The presented geochronometric data have allowed us to consider the age of oxbow lake organic deposits completely reliable and refer the time of their formation to the Tyrbei warming within the MIS-3. The applicability of the new version of the 230Th/U method for dating of interglacial and interstadial deposits, for the purpose of solving the Middle and Late Neopleistocene chronostratigraphy issues, is confirmed.
ZyFISH: A Simple, Rapid and Reliable Zygosity Assay for Transgenic Mice
McHugh, Donal; O’Connor, Tracy; Bremer, Juliane; Aguzzi, Adriano
2012-01-01
Microinjection of DNA constructs into fertilized mouse oocytes typically results in random transgene integration at a single genomic locus. The resulting transgenic founders can be used to establish hemizygous transgenic mouse lines. However, practical and experimental reasons often require that such lines be bred to homozygosity. Transgene zygosity can be determined by progeny testing assays which are expensive and time-consuming, by quantitative Southern blotting which is labor-intensive, or by quantitative PCR (qPCR) which requires transgene-specific design. Here, we describe a zygosity assessment procedure based on fluorescent in situ hybridization (zyFISH). The zyFISH protocol entails the detection of transgenic loci by FISH and the concomitant assignment of homozygosity using a concise and unbiased scoring system. The method requires small volumes of blood, is scalable to at least 40 determinations per assay, and produces results entirely consistent with the progeny testing assay. This combination of reliability, simplicity and cost-effectiveness makes zyFISH a method of choice for transgenic mouse zygosity determinations. PMID:22666404
Cyclic Solvent Vapor Annealing for Rapid, Robust Vertical Orientation of Features in BCP Thin Films
NASA Astrophysics Data System (ADS)
Paradiso, Sean; Delaney, Kris; Fredrickson, Glenn
2015-03-01
Methods for reliably controlling block copolymer self assembly have seen much attention over the past decade as new applications for nanostructured thin films emerge in the fields of nanopatterning and lithography. While solvent assisted annealing techniques are established as flexible and simple methods for achieving long range order, solvent annealing alone exhibits a very weak thermodynamic driving force for vertically orienting domains with respect to the free surface. To address the desire for oriented features, we have investigated a cyclic solvent vapor annealing (CSVA) approach that combines the mobility benefits of solvent annealing with selective stress experienced by structures oriented parallel to the free surface as the film is repeatedly swollen with solvent and dried. Using dynamical self-consistent field theory (DSCFT) calculations, we establish the conditions under which the method significantly outperforms both static and cyclic thermal annealing and implicate the orientation selection as a consequence of the swelling/deswelling process. Our results suggest that CSVA may prove to be a potent method for the rapid formation of highly ordered, vertically oriented features in block copolymer thin films.
Evaluation of quantitative PCR measurement of bacterial colonization of epithelial cells.
Schmidt, Marcin T; Olejnik-Schmidt, Agnieszka K; Myszka, Kamila; Borkowska, Monika; Grajek, Włodzimierz
2010-01-01
Microbial colonization is an important step in establishing pathogenic or probiotic relations to host cells and in biofilm formation on industrial or medical devices. The aim of this work was to verify the applicability of quantitative PCR (Real-Time PCR) to measure bacterial colonization of epithelial cells. Salmonella enterica and Caco-2 intestinal epithelial cell line was used as a model. To verify sensitivity of the assay a competition of the pathogen cells to probiotic microorganism was tested. The qPCR method was compared to plate count and radiolabel approach, which are well established techniques in this area of research. The three methods returned similar results. The best quantification accuracy had radiolabel method, followed by qPCR. The plate count results showed coefficient of variation two-times higher than this of qPCR. The quantitative PCR proved to be a reliable method for enumeration of microbes in colonization assay. It has several advantages that make it very useful in case of analyzing mixed populations, where several different species or even strains can be monitored at the same time.
Infrared Drying as a Quick Preparation Method for Dried Tangerine Peel
Xu, Mingyue; Zhao, Chengying; Ahmad, Aftab; Zhang, Huijuan; Xiao, Hang
2017-01-01
To establish the most convenient and effective method to dry tangerine peels, different methods (sun drying, hot-air drying, freeze drying, vacuum drying, and medium- and short-wave infrared drying) were exploited. Our results indicated that medium- and short-wave infrared drying was the best method to preserve nutraceutical components; for example, vitamin C was raised to 6.77 mg/g (D.W.) from 3.39 mg/g (sun drying). Moreover, the drying time can be shortened above 96% compared with sun drying. Importantly, the efficiency of DPPH radical scavenging was enhanced from 26.66% to 55.92%. These findings would provide a reliable and time-saving methodology to produce high-quality dried tangerine peels. PMID:29348752
A Study of Wind Turbine Comprehensive Operational Assessment Model Based on EM-PCA Algorithm
NASA Astrophysics Data System (ADS)
Zhou, Minqiang; Xu, Bin; Zhan, Yangyan; Ren, Danyuan; Liu, Dexing
2018-01-01
To assess wind turbine performance accurately and provide theoretical basis for wind farm management, a hybrid assessment model based on Entropy Method and Principle Component Analysis (EM-PCA) was established, which took most factors of operational performance into consideration and reach to a comprehensive result. To verify the model, six wind turbines were chosen as the research objects, the ranking obtained by the method proposed in the paper were 4#>6#>1#>5#>2#>3#, which are completely in conformity with the theoretical ranking, which indicates that the reliability and effectiveness of the EM-PCA method are high. The method could give guidance for processing unit state comparison among different units and launching wind farm operational assessment.
Wikipedia mining of hidden links between political leaders
NASA Astrophysics Data System (ADS)
Frahm, Klaus M.; Jaffrès-Runser, Katia; Shepelyansky, Dima L.
2016-12-01
We describe a new method of reduced Google matrix which allows to establish direct and hidden links between a subset of nodes of a large directed network. This approach uses parallels with quantum scattering theory, developed for processes in nuclear and mesoscopic physics and quantum chaos. The method is applied to the Wikipedia networks in different language editions analyzing several groups of political leaders of USA, UK, Germany, France, Russia and G20. We demonstrate that this approach allows to recover reliably direct and hidden links among political leaders. We argue that the reduced Google matrix method can form the mathematical basis for studies in social and political sciences analyzing Leader-Members eXchange (LMX).
2013-01-01
Summary of background data Recent smartphones, such as the iPhone, are often equipped with an accelerometer and magnetometer, which, through software applications, can perform various inclinometric functions. Although these applications are intended for recreational use, they have the potential to measure and quantify range of motion. The purpose of this study was to estimate the intra and inter-rater reliability as well as the criterion validity of the clinometer and compass applications of the iPhone in the assessment cervical range of motion in healthy participants. Methods The sample consisted of 28 healthy participants. Two examiners measured cervical range of motion of each participant twice using the iPhone (for the estimation of intra and inter-reliability) and once with the CROM (for the estimation of criterion validity). Estimates of reliability and validity were then established using the intraclass correlation coefficient (ICC). Results We observed a moderate intra-rater reliability for each movement (ICC = 0.65-0.85) but a poor inter-rater reliability (ICC < 0.60). For the criterion validity, the ICCs are moderate (>0.50) to good (>0.65) for movements of flexion, extension, lateral flexions and right rotation, but poor (<0.50) for the movement left rotation. Conclusion We found good intra-rater reliability and lower inter-rater reliability. When compared to the gold standard, these applications showed moderate to good validity. However, before using the iPhone as an outcome measure in clinical settings, studies should be done on patients presenting with cervical problems. PMID:23829201
Regulatory observations in bioanalytical determinations.
Viswanathan, C T
2010-07-01
The concept of measuring analytes in biological media is a long-established area of the quantitative sciences that is employed in many sectors. While academic research and R&D units of private firms have been in the forefront of developing complex methodologies, it is the regulatory environment that has brought the focus and rigor to the quality control of the quantitative determination of drug concentration in biological samples. In this article, the author examines the regulatory findings discovered during the course of several years of auditing bioanalytical work. The outcomes of these findings underscore the importance of quality method validation to ensure the reliability of the data generated. The failure to ensure the reliability of these data can lead to potential risks in the health management of millions of people in the USA.
Wei, Wenhui; Gao, Zhaohui; Gao, Shesheng; Jia, Ke
2018-04-09
In order to meet the requirements of autonomy and reliability for the navigation system, combined with the method of measuring speed by using the spectral redshift information of the natural celestial bodies, a new scheme, consisting of Strapdown Inertial Navigation System (SINS)/Spectral Redshift (SRS)/Geomagnetic Navigation System (GNS), is designed for autonomous integrated navigation systems. The principle of this SINS/SRS/GNS autonomous integrated navigation system is explored, and the corresponding mathematical model is established. Furthermore, a robust adaptive central difference particle filtering algorithm is proposed for this autonomous integrated navigation system. The simulation experiments are conducted and the results show that the designed SINS/SRS/GNS autonomous integrated navigation system possesses good autonomy, strong robustness and high reliability, thus providing a new solution for autonomous navigation technology.
A conflict management scale for pharmacy.
Austin, Zubin; Gregory, Paul A; Martin, Craig
2009-11-12
To develop and establish the validity and reliability of a conflict management scale specific to pharmacy practice and education. A multistage inventory-item development process was undertaken involving 93 pharmacists and using a previously described explanatory model for conflict in pharmacy practice. A 19-item inventory was developed, field tested, and validated. The conflict management scale (CMS) demonstrated an acceptable degree of reliability and validity for use in educational or practice settings to promote self-reflection and self-awareness regarding individuals' conflict management styles. The CMS provides a unique, pharmacy-specific method for individuals to determine and reflect upon their own conflict management styles. As part of an educational program to facilitate self-reflection and heighten self-awareness, the CMS may be a useful tool to promote discussions related to an important part of pharmacy practice.
Assuring reliability program effectiveness.
NASA Technical Reports Server (NTRS)
Ball, L. W.
1973-01-01
An attempt is made to provide simple identification and description of techniques that have proved to be most useful either in developing a new product or in improving reliability of an established product. The first reliability task is obtaining and organizing parts failure rate data. Other tasks are parts screening, tabulation of general failure rates, preventive maintenance, prediction of new product reliability, and statistical demonstration of achieved reliability. Five principal tasks for improving reliability involve the physics of failure research, derating of internal stresses, control of external stresses, functional redundancy, and failure effects control. A final task is the training and motivation of reliability specialist engineers.
Jiang, Guangming; Wan, Xiaoju; Wang, Ming; Zhou, Jianhua; Pan, Jian; Wang, Baolong
2016-08-01
Mouse embryonic fibroblasts (MEFs) are widely used to prepare feeder layers for culturing embryonic stem cells (ESCs) or induced pluripotent stem cells (iPSCs) in vitro. Transportation lesions and exorbitant prices make the commercially obtained MEFs unsuitable for long term research. The aim of present study is to establish a method, which enables researchers to gain MEFs from mice and establish feeder layers by themselves in ordinary laboratories. MEFs were isolated from ICR mouse embryos at 12.5-17.5 day post-coitum (DPC) and cultured in vitro. At P2-P7, the cells were inactivated with mitomycin C or by X-ray irradiation. Then they were used to prepare feeder layers. The key factors of the whole protocol were analyzed to determine the optimal conditions for the method. The results revealed MEFs isolated at 12.5-13.5 DPC, and cultured to P3 were the best choice for feeder preparation, those P2 and P4-P5 MEFs were also suitable for the purpose. The P3-P5 MEFs treated with 10 μg/ml of mitomycin C for 3 h, or irradiated with X-ray at 1.5 Gy/min for 25 Gy were the most suitable feeder cells. Treating MEFs with 10 μg/ml of mitomycin C for 2.5 h, 15 μg/ml for 2.0 h, or irradiating the cells with 20 Gy of X-ray at 2.0 Gy/min could all serve as alternative methods for P3-P4 cells. Our study provides a reliable and economical way to obtain large amount of qualified MEFs for long term research of ESCs or iPSCs.
2011-05-01
Medical Institute’s publications Web site: www.faa.gov/library/reports/medical/oamtechreports i Technical Report Documentation Page 1. Report No. 2...Study One provided evidence of the reliability of the subtests, established performance norms for subjects with normal color vision ( NCV ) on each...Two provided evidence of the reliability of second operational ATCOV subtests, established performance norms for NCV subjects on each subtest
Zeilinger, Markus; Pichler, Florian; Nics, Lukas; Wadsak, Wolfgang; Spreitzer, Helmut; Hacker, Marcus; Mitterhauser, Markus
2017-12-01
Resolving the kinetic mechanisms of biomolecular interactions have become increasingly important in early-phase drug development. Since traditional in vitro methods belong to dose-dependent assessments, binding kinetics is usually overlooked. The present study aimed at the establishment of two novel experimental approaches for the assessment of binding affinity of both, radiolabelled and non-labelled compounds targeting the A 3 R, based on high-resolution real-time data acquisition of radioligand-receptor binding kinetics. A novel time-resolved competition assay was developed and applied to determine the K i of eight different A 3 R antagonists, using CHO-K1 cells stably expressing the hA 3 R. In addition, a new kinetic real-time cell-binding approach was established to quantify the rate constants k on and k off , as well as the dedicated K d of the A 3 R agonist [ 125 I]-AB-MECA. Furthermore, lipophilicity measurements were conducted to control influences due to physicochemical properties of the used compounds. Two novel real-time cell-binding approaches were successfully developed and established. Both experimental procedures were found to visualize the kinetic binding characteristics with high spatial and temporal resolution, resulting in reliable affinity values, which are in good agreement with values previously reported with traditional methods. Taking into account the lipophilicity of the A 3 R antagonists, no influences on the experimental performance and the resulting affinity were investigated. Both kinetic binding approaches comprise tracer administration and subsequent binding to living cells, expressing the dedicated target protein. Therefore, the experiments resemble better the true in vivo physiological conditions and provide important markers of cellular feedback and biological response.
Irinyi, Laszlo; Serena, Carolina; Garcia-Hermoso, Dea; Arabatzis, Michael; Desnos-Ollivier, Marie; Vu, Duong; Cardinali, Gianluigi; Arthur, Ian; Normand, Anne-Cécile; Giraldo, Alejandra; da Cunha, Keith Cassia; Sandoval-Denis, Marcelo; Hendrickx, Marijke; Nishikaku, Angela Satie; de Azevedo Melo, Analy Salles; Merseguel, Karina Bellinghausen; Khan, Aziza; Parente Rocha, Juliana Alves; Sampaio, Paula; da Silva Briones, Marcelo Ribeiro; e Ferreira, Renata Carmona; de Medeiros Muniz, Mauro; Castañón-Olivares, Laura Rosio; Estrada-Barcenas, Daniel; Cassagne, Carole; Mary, Charles; Duan, Shu Yao; Kong, Fanrong; Sun, Annie Ying; Zeng, Xianyu; Zhao, Zuotao; Gantois, Nausicaa; Botterel, Françoise; Robbertse, Barbara; Schoch, Conrad; Gams, Walter; Ellis, David; Halliday, Catriona; Chen, Sharon; Sorrell, Tania C; Piarroux, Renaud; Colombo, Arnaldo L; Pais, Célia; de Hoog, Sybren; Zancopé-Oliveira, Rosely Maria; Taylor, Maria Lucia; Toriello, Conchita; de Almeida Soares, Célia Maria; Delhaes, Laurence; Stubbe, Dirk; Dromer, Françoise; Ranque, Stéphane; Guarro, Josep; Cano-Lira, Jose F; Robert, Vincent; Velegraki, Aristea; Meyer, Wieland
2015-05-01
Human and animal fungal pathogens are a growing threat worldwide leading to emerging infections and creating new risks for established ones. There is a growing need for a rapid and accurate identification of pathogens to enable early diagnosis and targeted antifungal therapy. Morphological and biochemical identification methods are time-consuming and require trained experts. Alternatively, molecular methods, such as DNA barcoding, a powerful and easy tool for rapid monophasic identification, offer a practical approach for species identification and less demanding in terms of taxonomical expertise. However, its wide-spread use is still limited by a lack of quality-controlled reference databases and the evolving recognition and definition of new fungal species/complexes. An international consortium of medical mycology laboratories was formed aiming to establish a quality controlled ITS database under the umbrella of the ISHAM working group on "DNA barcoding of human and animal pathogenic fungi." A new database, containing 2800 ITS sequences representing 421 fungal species, providing the medical community with a freely accessible tool at http://www.isham.org/ and http://its.mycologylab.org/ to rapidly and reliably identify most agents of mycoses, was established. The generated sequences included in the new database were used to evaluate the variation and overall utility of the ITS region for the identification of pathogenic fungi at intra-and interspecies level. The average intraspecies variation ranged from 0 to 2.25%. This highlighted selected pathogenic fungal species, such as the dermatophytes and emerging yeast, for which additional molecular methods/genetic markers are required for their reliable identification from clinical and veterinary specimens. © The Author 2015. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
76 FR 58716 - Interpretation of Transmission Planning Reliability Standard
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-22
... directs NERC and Commission staff to initiate a process to identify any reliability issues, as discussed... Commission directs NERC and Commission staff to initiate a process to identify any reliability issues, as... established a process to select and certify an ERO,\\5\\ and subsequently certified NERC.\\6\\ On April 4, 2006...
How to Measure the Onset of Babbling Reliably?
ERIC Educational Resources Information Center
Molemans, Inge; van den Berg, Renate; van Severen, Lieve; Gillis, Steven
2012-01-01
Various measures for identifying the onset of babbling have been proposed in the literature, but a formal definition of the exact procedure and a thorough validation of the sample size required for reliably establishing babbling onset is lacking. In this paper the reliability of five commonly used measures is assessed using a large longitudinal…
Teaching acute care nurses cognitive assessment using LOCFAS: what's the best method?
Flannery, J; Land, K
2001-02-01
The Levels of Cognitive Functioning Assessment Scale (LOCFAS) is a behavioral checklist used by nurses in the acute care setting to assess the level of cognitive functioning in severely brain-injured patients in the early post-trauma period. Previous research studies have supported the reliability and validity of LOCFAS. For LOCFAS to become a more firmly established method of cognitive assessment, nurses must become familiar with and proficient in the use of this instrument. The purpose of this study was to find the most effective method of instruction by comparing three methods: a self-directed manual, a teaching video, and a classroom presentation. Videotaped vignettes of actual brain-injured patients were presented at the end of each training session, and participants were required to categorize these videotaped patients by using LOCFAS. High levels of reliability were observed for both the self-directed manual group and the teaching video group, but an overall lower level of reliability was observed for the classroom presentation group. Examination of the accuracy of overall LOCFAS ratings revealed a significant difference for instructional groups; the accuracy of the classroom presentation group was significantly lower than that of either the self-directed manual group or the teaching video group. The three instructional groups also differed on the average accuracy of ratings of the individual behaviors; the accuracy of the classroom presentation group was significantly lower than that of the teaching video group, whereas the self-directed manual group fell in between. Nurses also rated the instructional methods across a number of evaluative dimensions on a 5-point Likert-type scale. Evaluative statements ranged from average to good, with no significant differences among instructional methods.
Karbalaie, Abdolamir; Abtahi, Farhad; Fatemi, Alimohammad; Etehadtavakol, Mahnaz; Emrani, Zahra; Erlandsson, Björn-Erik
2017-09-01
Nailfold capillaroscopy is a practical method for identifying and obtaining morphological changes in capillaries which might reveal relevant information about diseases and health. Capillaroscopy is harmless, and seems simple and repeatable. However, there is lack of established guidelines and instructions for acquisition as well as the interpretation of the obtained images; which might lead to various ambiguities. In addition, assessment and interpretation of the acquired images are very subjective. In an attempt to overcome some of these problems, in this study a new modified technique for assessment of nailfold capillary density is introduced. The new method is named elliptic broken line (EBL) which is an extension of the two previously known methods by defining clear criteria for finding the apex of capillaries in different scenarios by using a fitted elliptic. A graphical user interface (GUI) is developed for pre-processing, manual assessment of capillary apexes and automatic correction of selected apexes based on 90° rule. Intra- and inter-observer reliability of EBL and corrected EBL is evaluated in this study. Four independent observers familiar with capillaroscopy performed the assessment for 200 nailfold videocapillaroscopy images, form healthy subject and systemic lupus erythematosus patients, in two different sessions. The results show elevation from moderate (ICC=0.691) and good (ICC=0.753) agreements to good (ICC=0.750) and good (ICC=0.801) for intra- and inter-observer reliability after automatic correction of EBL. This clearly shows the potential of this method to improve the reliability and repeatability of assessment which motivates us for further development of automatic tool for EBL method. Copyright © 2017 Elsevier Inc. All rights reserved.
Ahern, Tracey; Gardner, Anne; Gardner, Glenn; Middleton, Sandy; Della, Phillip
2013-05-01
The final phase of a three phase study analysing the implementation and impact of the nurse practitioner role in Australia (the Australian Nurse Practitioner Project or AUSPRAC) was undertaken in 2009, requiring nurse telephone interviewers to gather information about health outcomes directly from patients and their treating nurse practitioners. A team of several registered nurses was recruited and trained as telephone interviewers. The aim of this paper is to report on development and evaluation of the training process for telephone interviewers. The training process involved planning the content and methods to be used in the training session; delivering the session; testing skills and understanding of interviewers post-training; collecting and analysing data to determine the degree to which the training process was successful in meeting objectives and post-training follow-up. All aspects of the training process were informed by established educational principles. Interrater reliability between interviewers was high for well-validated sections of the survey instrument resulting in 100% agreement between interviewers. Other sections with unvalidated questions showed lower agreement (between 75% and 90%). Overall the agreement between interviewers was 92%. Each interviewer was also measured against a specifically developed master script or gold standard and for this each interviewer achieved a percentage of correct answers of 94.7% or better. This equated to a Kappa value of 0.92 or better. The telephone interviewer training process was very effective and achieved high interrater reliability. We argue that the high reliability was due to the use of well validated instruments and the carefully planned programme based on established educational principles. There is limited published literature on how to successfully operationalise educational principles and tailor them for specific research studies; this report addresses this knowledge gap. Copyright © 2012 Elsevier Ltd. All rights reserved.
Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye
2016-01-13
A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.
Song, Y; Kato, N; Liu, C; Matsumiya, Y; Kato, H; Watanabe, K
2000-06-15
Rapid and reliable two-step multiplex polymerase chain reaction (PCR) assays were established to identify human intestinal lactobacilli; a multiplex PCR was used for grouping of lactobacilli with a mixture of group-specific primers followed by four multiplex PCR assays with four sorts of species-specific primer mixtures for identification at the species level. Primers used were designed from nucleotide sequences of the 16S-23S rRNA intergenic spacer region and its flanking 23S rRNA gene of members of the genus Lactobacillus which are commonly isolated from human stool specimens: Lactobacillus acidophilus, Lactobacillus crispatus, Lactobacillus delbrueckii (ssp. bulgaricus and ssp. lactis), Lactobacillus fermentum, Lactobacillus gasseri, Lactobacillus jensenii, Lactobacillus paracasei (ssp. paracasei and ssp. tolerans), Lactobacillus plantarum, Lactobacillus reuteri, Lactobacillus rhamnosus and Lactobacillus salivarius (ssp. salicinius and ssp. salivarius). The established two-step multiplex PCR assays were applied to the identification of 84 Lactobacillus strains isolated from human stool specimens and the PCR results were consistent with the results from the DNA-DNA hybridization assay. These results suggest that the multiplex PCR system established in this study is a simple, rapid and reliable method for the identification of common Lactobacillus isolates from human stool samples.
Developing safety performance functions incorporating reliability-based risk measures.
Ibrahim, Shewkar El-Bassiouni; Sayed, Tarek
2011-11-01
Current geometric design guides provide deterministic standards where the safety margin of the design output is generally unknown and there is little knowledge of the safety implications of deviating from these standards. Several studies have advocated probabilistic geometric design where reliability analysis can be used to account for the uncertainty in the design parameters and to provide a risk measure of the implication of deviation from design standards. However, there is currently no link between measures of design reliability and the quantification of safety using collision frequency. The analysis presented in this paper attempts to bridge this gap by incorporating a reliability-based quantitative risk measure such as the probability of non-compliance (P(nc)) in safety performance functions (SPFs). Establishing this link will allow admitting reliability-based design into traditional benefit-cost analysis and should lead to a wider application of the reliability technique in road design. The present application is concerned with the design of horizontal curves, where the limit state function is defined in terms of the available (supply) and stopping (demand) sight distances. A comprehensive collision and geometric design database of two-lane rural highways is used to investigate the effect of the probability of non-compliance on safety. The reliability analysis was carried out using the First Order Reliability Method (FORM). Two Negative Binomial (NB) SPFs were developed to compare models with and without the reliability-based risk measures. It was found that models incorporating the P(nc) provided a better fit to the data set than the traditional (without risk) NB SPFs for total, injury and fatality (I+F) and property damage only (PDO) collisions. Copyright © 2011 Elsevier Ltd. All rights reserved.
Pritchard, N Stewart; Smoliga, James M; Nguyen, Anh-Dung; Branscomb, Micah C; Sinacore, David R; Taylor, Jeffrey B; Ford, Kevin R
2017-01-01
Metatarsal fractures, especially of the fifth metatarsal, are common injuries of the foot in a young athletic population, but the risk factors for this injury are not well understood. Dual-energy x-ray absorptiometry (DXA) provides reliable measures of regional bone mineral density to predict fracture risk in the hip and lumbar spine. Recently, sub-regional metatarsal reliability was established in fresh cadaveric specimens and associated with ultimate fracture force. The purpose of this study was to assess the reliability of DXA bone mineral density measurements of sub-regions of the second and fifth metatarsals in a young, active population. Thirty two recreationally active individuals participated in the study, and the bone density of the second (2MT) and fifth (5MT) metatarsals of each subject was measured using a Hologic QDR x-ray bone densitometer. Scans were analyzed separately by two raters, and regional bone mineral density, bone mineral content, and area measurements were calculated for the proximal, shaft, and distal regions of the bone. Intra-rater, inter-rater, and scan-rescan reliability were then determined for each region. Proximal and shaft bone mineral density measurements of the second and fifth metatarsal were reliable. ICC's were variable across regions and metatarsals, with the distal region being the poorest. Bone mineral density measurements of the metatarsals may be a better indicator of fracture risk of the metatarsals than whole body measurements. A reliable method for measuring the regional bone mineral densities of the metatarsals was found. However, inter-rater reliability and scan-rescan reliability for the distal regions were poor. Future research should examine the relationship between DXA bone mineral density measurements and fracture risk at the metatarsals.
Cardamone-Breen, Mairead C.; Jorm, Anthony F.; Lawrence, Katherine A.; Mackinnon, Andrew J.
2017-01-01
Background Despite substantial evidence demonstrating numerous parental risk and protective factors for the development of adolescent depression and anxiety disorders, there is currently no single measure that assesses these parenting factors. To address this gap, we developed the Parenting to Reduce Adolescent Depression and Anxiety Scale (PRADAS) as a criterion-referenced measure of parental concordance with a set of evidence-based parenting guidelines for the prevention of adolescent depression and anxiety disorders. In this paper, we used a sample of Australian parents of adolescents to: (1) validate the PRADAS as a criterion-referenced measure; (2) examine parental concordance with the guidelines in the sample; and (3) examine correlates of parental concordance with the guidelines. Methods Seven hundred eleven parents completed the PRADAS, as well as two established parenting measures, and parent-report measures of adolescent depression and anxiety symptoms. Six hundred sixty adolescent participants (aged 12–15) also completed the symptom measures. Concordance with the guidelines was assessed via nine subscale scores and a total score. Reliability of the scores was assessed with an estimate of the agreement coefficient, as well as 1-month test-retest reliability. Convergent validity was examined via correlations between the scale and two established parenting measures. Results One proposed subscale was removed from the final version of the scale, resulting in a total of eight subscales. Reliability was high for the total score, and acceptable to high for seven of the eight subscales. One-month test-retest reliability was acceptable to high for the total score. Convergent validity was supported by moderate to high correlations with two established measures of parenting. Overall, rates of parental concordance with the guidelines were low in our sample. Higher scores were associated with being female and higher levels of parental education. Greater parental concordance with the guidelines was associated with fewer symptoms of depression and anxiety in adolescent participants. Discussion This initial validation study provides preliminary support for the reliability and validity of the PRADAS. The scale has potential for use in both clinical and research settings. It may be used to identify parents’ strengths and potential targets for intervention, and as an outcome measure in studies of preventive parenting interventions. PMID:28951815
A Novel Imaging Analysis Method for Capturing Pharyngeal Constriction During Swallowing.
Schwertner, Ryan W; Garand, Kendrea L; Pearson, William G
2016-01-01
Videofluoroscopic imaging of swallowing known as the Modified Barium Study (MBS) is the standard of care for assessing swallowing difficulty. While the clinical purpose of this radiographic imaging is to primarily assess aspiration risk, valuable biomechanical data is embedded in these studies. Computational analysis of swallowing mechanics (CASM) is an established research methodology for assessing multiple interactions of swallowing mechanics based on coordinates mapping muscle function including hyolaryngeal movement, pharyngeal shortening, tongue base retraction, and extension of the head and neck, however coordinates characterizing pharyngeal constriction is undeveloped. The aim of this study was to establish a method for locating the superior and middle pharyngeal constrictors using hard landmarks as guides on MBS videofluoroscopic imaging, and to test the reliability of this new method. Twenty de-identified, normal, MBS videos were randomly selected from a database. Two raters annotated landmarks for the superior and middle pharyngeal constrictors frame-by-frame using a semi-automated MATLAB tracker tool at two time points. Intraclass correlation coefficients were used to assess test-retest reliability between two raters with an ICC = 0.99 or greater for all coordinates for the retest measurement. MorphoJ integrated software was used to perform a discriminate function analysis to visualize how all 12 coordinates interact with each other in normal swallowing. The addition of the superior and middle pharyngeal constrictor coordinates to CASM allows for a robust analysis of the multiple components of swallowing mechanics interacting with a wide range of variables in both patient specific and cohort studies derived from common use imaging data.
A Novel Imaging Analysis Method for Capturing Pharyngeal Constriction During Swallowing
Schwertner, Ryan W.; Garand, Kendrea L.; Pearson, William G.
2016-01-01
Videofluoroscopic imaging of swallowing known as the Modified Barium Study (MBS) is the standard of care for assessing swallowing difficulty. While the clinical purpose of this radiographic imaging is to primarily assess aspiration risk, valuable biomechanical data is embedded in these studies. Computational analysis of swallowing mechanics (CASM) is an established research methodology for assessing multiple interactions of swallowing mechanics based on coordinates mapping muscle function including hyolaryngeal movement, pharyngeal shortening, tongue base retraction, and extension of the head and neck, however coordinates characterizing pharyngeal constriction is undeveloped. The aim of this study was to establish a method for locating the superior and middle pharyngeal constrictors using hard landmarks as guides on MBS videofluoroscopic imaging, and to test the reliability of this new method. Twenty de-identified, normal, MBS videos were randomly selected from a database. Two raters annotated landmarks for the superior and middle pharyngeal constrictors frame-by-frame using a semi-automated MATLAB tracker tool at two time points. Intraclass correlation coefficients were used to assess test-retest reliability between two raters with an ICC = 0.99 or greater for all coordinates for the retest measurement. MorphoJ integrated software was used to perform a discriminate function analysis to visualize how all 12 coordinates interact with each other in normal swallowing. The addition of the superior and middle pharyngeal constrictor coordinates to CASM allows for a robust analysis of the multiple components of swallowing mechanics interacting with a wide range of variables in both patient specific and cohort studies derived from common use imaging data. PMID:28239682
Isoelectric points and points of zero charge of metal (hydr)oxides: 50years after Parks' review.
Kosmulski, Marek
2016-12-01
The pH-dependent surface charging of metal (hydr)oxides is reviewed on the occasion of the 50th anniversary of the publication by G.A. Parks: "Isoelectric points of solid oxides, solid hydroxides, and aqueous hydroxo complex systems" in Chemical Reviews. The point of zero charge (PZC) and isoelectric point (IEP) became standard parameters to characterize metal oxides in aqueous dispersions, and they define adsorption (surface excess) of ions, stability against coagulation, rheological properties of dispersions, etc. They are commonly used in many branches of science including mineral processing, soil science, materials science, geochemistry, environmental engineering, and corrosion science. Parks established standard procedures and experimental conditions which are required to obtain reliable and reproducible values of PZC and IEP. The field is very active, and the number of related papers exceeds 300 a year, and the standards established by Parks remain still valid. Relevant experimental techniques improved over the years, especially the measurements of electrophoretic mobility became easier and more reliable, are the numerical values of PZC and IEP compiled by Parks were confirmed by contemporary publications with a few exceptions. The present paper is an up-to-date compilation of the values of PZC and IEP of metal oxides. Unlike in former reviews by the same author, which were more comprehensive, only limited number of selected results are presented and discussed here. On top of the results obtained by means of classical methods (titration and electrokinetic methods), new methods and correlations found over the recent 50years are presented. Copyright © 2016 Elsevier B.V. All rights reserved.
Benej, Martin; Bendlova, Bela; Vaclavikova, Eliska; Poturnajova, Martina
2011-10-06
Reliable and effective primary screening of mutation carriers is the key condition for common diagnostic use. The objective of this study is to validate the method high resolution melting (HRM) analysis for routine primary mutation screening and accomplish its optimization, evaluation and validation. Due to their heterozygous nature, germline point mutations of c-RET proto-oncogene, associated to multiple endocrine neoplasia type 2 (MEN2), are suitable for HRM analysis. Early identification of mutation carriers has a major impact on patients' survival due to early onset of medullary thyroid carcinoma (MTC) and resistance to conventional therapy. The authors performed a series of validation assays according to International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines for validation of analytical procedures, along with appropriate design and optimization experiments. After validated evaluation of HRM, the method was utilized for primary screening of 28 pathogenic c-RET mutations distributed among nine exons of c-RET gene. Validation experiments confirm the repeatability, robustness, accuracy and reproducibility of HRM. All c-RET gene pathogenic variants were detected with no occurrence of false-positive/false-negative results. The data provide basic information about design, establishment and validation of HRM for primary screening of genetic variants in order to distinguish heterozygous point mutation carriers among the wild-type sequence carriers. HRM analysis is a powerful and reliable tool for rapid and cost-effective primary screening, e.g., of c-RET gene germline and/or sporadic mutations and can be used as a first line potential diagnostic tool.
A low-cost, tablet-based option for prehospital neurologic assessment
Chapman Smith, Sherita N.; Govindarajan, Prasanthi; Padrick, Matthew M.; Lippman, Jason M.; McMurry, Timothy L.; Resler, Brian L.; Keenan, Kevin; Gunnell, Brian S.; Mehndiratta, Prachi; Chee, Christina Y.; Cahill, Elizabeth A.; Dietiker, Cameron; Cattell-Gordon, David C.; Smith, Wade S.; Perina, Debra G.; Solenski, Nina J.; Worrall, Bradford B.
2016-01-01
Objectives: In this 2-center study, we assessed the technical feasibility and reliability of a low cost, tablet-based mobile telestroke option for ambulance transport and hypothesized that the NIH Stroke Scale (NIHSS) could be performed with similar reliability between remote and bedside examinations. Methods: We piloted our mobile telemedicine system in 2 geographic regions, central Virginia and the San Francisco Bay Area, utilizing commercial cellular networks for videoconferencing transmission. Standardized patients portrayed scripted stroke scenarios during ambulance transport and were evaluated by independent raters comparing bedside to remote mobile telestroke assessments. We used a mixed-effects regression model to determine intraclass correlation of the NIHSS between bedside and remote examinations (95% confidence interval). Results: We conducted 27 ambulance runs at both sites and successfully completed the NIHSS for all prehospital assessments without prohibitive technical interruption. The mean difference between bedside (face-to-face) and remote (video) NIHSS scores was 0.25 (1.00 to −0.50). Overall, correlation of the NIHSS between bedside and mobile telestroke assessments was 0.96 (0.92–0.98). In the mixed-effects regression model, there were no statistically significant differences accounting for method of evaluation or differences between sites. Conclusions: Utilizing a low-cost, tablet-based platform and commercial cellular networks, we can reliably perform prehospital neurologic assessments in both rural and urban settings. Further research is needed to establish the reliability and validity of prehospital mobile telestroke assessment in live patients presenting with acute neurologic symptoms. PMID:27281534
2013-01-01
Background This study evaluated the score reliability and equivalence of factor structure of the Sociocultural Attitudes towards Appearance Questionnaire-3 (SATAQ-3) [1] in a sample of female college students from the four largest ethnic groups in the USA. Methods Participants were 1245 women who self-identified as European American/White (n = 543), African American/Black (n = 137), Asian American (n = 317), or Latina/Hispanic (n = 248). All completed the SATAQ-3 and a demographic questionnaire. To test the factor similarity and score reliability across groups, we used exploratory factor analysis and calculated Cronbach’s alphas (respectively). Results Score reliability was high for all groups. Tests of factor equivalence suggested that the four pre-established factors of the SATAQ-3 (i.e., knowledge, perceived pressure, thin-ideal internalization, athletic-ideal internalization) were similar for women of all ethnic groups. Only two items (20 and 27) did not consistently load on the previously identified scale across all four groups. When scored, African Americans reported significantly less perceived pressure and internalization than all other groups. Conclusions Results support the use of the SATAQ-3 in female college students of these four ethnicities. PMID:24999395
Measuring first-line nurse manager work: instrument: development and testing.
Cadmus, Edna; Wisniewska, Edyta K
2013-12-01
The objective of this study was to develop and test a 1st-line nurse manager (FLNM) work instrument to measure categories of work and frequency of activities. First-line nurse managers have been demonstrated to be key contributors in meeting organizational outcomes and patient and nurse satisfaction. Identifying the work of FLNMs is essential to help in the development of prioritization and sequence. The need for an instrument that can measure and categorize the work of FLNMs is indicated. The author-developed instrument was administered as a pilot study to 173 FLNMs in New Jersey. Descriptive statistics were analyzed, and validity and reliability were measured. Content validity was established through 2 focus groups using 10 FLNMs and conducting a survey of 5 chief nursing officers. Reliability was assessed by 13 of 16 FLNM participants using the test/retest method and quantified using percent agreement within a 10-day period. Those items with 70% agreement or more were identified as reliable and retained on the instrument. The content validity of the instrument is strong; further refinement and testing of the tool are indicated to improve the reliability and generalizability across multiple populations of leaders and settings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aydin, Süleyman, E-mail: yupul@hotmail.com; Haşiloğlu, M. Akif, E-mail: mehmet.hasiloglu@hotmail.com; Kunduraci, Ayşe, E-mail: ayse-kndrc@hotmail.com
In this study it was aimed to improve an academic achievement test to establish the students’ knowledge about the earthquake and the ways of protection from earthquakes. In the method of this study, the steps that Webb (1994) was created to improve an academic achievement test for a unit were followed. In the developmental process of multiple choice test having 25 questions, was prepared to measure the pre-service teachers’ knowledge levels about the earthquake and the ways of protection from earthquakes. The multiple choice test was presented to view of six academics (one of them was from geographic field andmore » five of them were science educator) and two expert teachers in science Prepared test was applied to 93 pre-service teachers studying in elementary education department in 2014-2015 academic years. As a result of validity and reliability of the study, the test was composed of 20 items. As a result of these applications, Pearson Moments Multiplication half-reliability coefficient was found to be 0.94. When this value is adjusted according to Spearman Brown reliability coefficient the reliability coefficient was set at 0.97.« less
Reliability modelling and analysis of a multi-state element based on a dynamic Bayesian network
NASA Astrophysics Data System (ADS)
Li, Zhiqiang; Xu, Tingxue; Gu, Junyuan; Dong, Qi; Fu, Linyu
2018-04-01
This paper presents a quantitative reliability modelling and analysis method for multi-state elements based on a combination of the Markov process and a dynamic Bayesian network (DBN), taking perfect repair, imperfect repair and condition-based maintenance (CBM) into consideration. The Markov models of elements without repair and under CBM are established, and an absorbing set is introduced to determine the reliability of the repairable element. According to the state-transition relations between the states determined by the Markov process, a DBN model is built. In addition, its parameters for series and parallel systems, namely, conditional probability tables, can be calculated by referring to the conditional degradation probabilities. Finally, the power of a control unit in a failure model is used as an example. A dynamic fault tree (DFT) is translated into a Bayesian network model, and subsequently extended to a DBN. The results show the state probabilities of an element and the system without repair, with perfect and imperfect repair, and under CBM, with an absorbing set plotted by differential equations and verified. Through referring forward, the reliability value of the control unit is determined in different kinds of modes. Finally, weak nodes are noted in the control unit.
Bai, Yeon; Peng, C-Y Joanne; Fly, Alyce D
2008-07-01
The purpose of this study was to create and establish the validity of a short questionnaire to measure mothers' perceived support for breastfeeding from the workplace. The items in the workplace breastfeeding support scale (WBSS) were derived from a literature review. The scale was self-administered in central Indiana during the fall of 2005 to a convenience sample of 66 volunteers who were primiparous, 6 to 12 months postpartum, worked outside home, and had initiated breastfeeding prior to the survey. Internal consistency (alpha) and split-half reliability (r) tests and a factor analysis were done to establish reliability and construct validity of the scale. The WBSS showed acceptable reliability (alpha=.77, r=0.86). Content validity was established by review using a panel of experts. Four distinct constructs of the scale were identified that accounted for 62.1% of the total variability of the scale: technical, environmental, facility, and peer support, thus establishing construct validity of the scale. Lactation consultants and worksite lactation program planners can use the WBSS to help mothers returning to work and to assess the needs for improvement of support programs.
Basques, Bryce A; Long, William D; Golinvaux, Nicholas S; Bohl, Daniel D; Samuel, Andre M; Lukasiewicz, Adam M; Webb, Matthew L; Grauer, Jonathan N
2017-06-01
Multiple methods are used to measure proximal junctional angle (PJA) and diagnose proximal junctional kyphosis (PJK) after fusion for adolescent idiopathic scoliosis (AIS); however, there is no gold standard. Previous studies using the three most common measurement methods, upper-instrumented vertebra (UIV)+1, UIV+2, and UIV to T2, have minimized the difficulty in obtaining these measurements, and often exclude patients for which measurements cannot be recorded. The purpose of this study is to assess the technical feasibility of measuring PJA and PJK in a series of AIS patients who have undergone posterior instrumented fusion and to assess the variability in results depending on the measurement technique used. A retrospective cohort study was carried out. There were 460 radiographs from 98 patients with AIS who underwent posterior spinal fusion at a single institution from 2006 through 2012. The outcomes for this study were the ability to obtain a PJA measurement for each method, the ability to diagnose PJK, and the inter- and intra-rater reliability of these measurements. Proximal junctional angle was determined by measuring the sagittal Cobb angle on preoperative and postoperative lateral upright films using the three most common methods (UIV+1, UIV+2, and UIV to T2). The ability to obtain a PJA measurement, the ability to assess PJK, and the total number of patients with a PJK diagnosis were tabulated for each method based on established definitions. Intra- and inter-rater reliability of each measurement method was assessed using intra-class correlation coefficients (ICCs). A total of 460 radiographs from 98 patients were evaluated. The average number of radiographs per patient was 5.3±1.7 (mean±standard deviation), with an average follow-up of 2.1 years (780±562 days). A PJA measurement was only readable on 13%-18% of preoperative filmsand 31%-49% of postoperative films (range based on measurement technique). Only 12%-31% of films were able to be assessed for PJK based on established definitions. The rate of PJK diagnosis ranged from 1% to 29%. Of these diagnoses, 21%-100% disappeared on at least one subsequent film for the given patient. ICC ranges for intra-rater and inter-rater reliability were 0.730-0.799 and 0.794-0.836, respectively. This study suggests significant limitations of the three most common methods of measuring and diagnosing PJK. The results of studies using these methods can be significantly affected based on the exclusion of patients for whom measurements cannot be made and choice of measurement technique. Copyright © 2015 Elsevier Inc. All rights reserved.
Brown Adipose Tissue Quantification in Human Neonates Using Water-Fat Separated MRI
Rasmussen, Jerod M.; Entringer, Sonja; Nguyen, Annie; van Erp, Theo G. M.; Guijarro, Ana; Oveisi, Fariba; Swanson, James M.; Piomelli, Daniele; Wadhwa, Pathik D.
2013-01-01
There is a major resurgence of interest in brown adipose tissue (BAT) biology, particularly regarding its determinants and consequences in newborns and infants. Reliable methods for non-invasive BAT measurement in human infants have yet to be demonstrated. The current study first validates methods for quantitative BAT imaging of rodents post mortem followed by BAT excision and re-imaging of excised tissues. Identical methods are then employed in a cohort of in vivo infants to establish the reliability of these measures and provide normative statistics for BAT depot volume and fat fraction. Using multi-echo water-fat MRI, fat- and water-based images of rodents and neonates were acquired and ratios of fat to the combined signal from fat and water (fat signal fraction) were calculated. Neonatal scans (n = 22) were acquired during natural sleep to quantify BAT and WAT deposits for depot volume and fat fraction. Acquisition repeatability was assessed based on multiple scans from the same neonate. Intra- and inter-rater measures of reliability in regional BAT depot volume and fat fraction quantification were determined based on multiple segmentations by two raters. Rodent BAT was characterized as having significantly higher water content than WAT in both in situ as well as ex vivo imaging assessments. Human neonate deposits indicative of bilateral BAT in spinal, supraclavicular and axillary regions were observed. Pairwise, WAT fat fraction was significantly greater than BAT fat fraction throughout the sample (ΔWAT-BAT = 38%, p<10−4). Repeated scans demonstrated a high voxelwise correlation for fat fraction (Rall = 0.99). BAT depot volume and fat fraction measurements showed high intra-rater (ICCBAT,VOL = 0.93, ICCBAT,FF = 0.93) and inter-rater reliability (ICCBAT,VOL = 0.86, ICCBAT,FF = 0.93). This study demonstrates the reliability of using multi-echo water-fat MRI in human neonates for quantification throughout the torso of BAT depot volume and fat fraction measurements. PMID:24205024
Weir, David R.; Wallace, Robert B.; Langa, Kenneth M.; Plassman, Brenda L.; Wilson, Robert S.; Bennett, David A.; Duara, Ranjan; Loewenstein, David; Ganguli, Mary; Sano, Mary
2011-01-01
Establishing methods for ascertainment of dementia and cognitive impairment that are accurate and also cost effective is a challenging enterprise. Large population-based studies often using administrative data sets offer relatively inexpensive but reliable estimates of severe conditions including moderate to advanced dementia that are useful for public health planning, but they can miss less severe cognitive impairment which may be the most effective point for intervention. Clinical and epidemiological cohorts, intensively assessed, provide more sensitive detection of less severe cognitive impairment but are often costly. Here, several approaches to ascertainment are evaluated for validity, reliability, and cost. In particular, the methods of ascertainment from the Health and Retirement Study (HRS) are described briefly, along with those of the Aging, Demographics, and Memory Study (ADAMS). ADAMS, a resource-intense sub-study of the HRS, was designed to provide diagnostic accuracy among persons with more advanced dementia. A proposal to streamline future ADAMS assessments is offered. Also considered are decision tree, algorithmic, and web-based approaches to diagnosis that can reduce the expense of clinical expertise and, in some contexts, can reduce the extent of data collection. These approaches are intended for intensively assessed epidemiological cohorts. The goal is valid and reliable detection with efficient and cost-effective tools. PMID:21255747
1980-04-01
incorporate the high reliability ceramic-packaged quartz crystal resonator developed at ERADCOM, and utilize beam -leaded devices wherever possible...the form of a truncated cylinder. The rather complex module outline is best accomplished through the use of a precast potting shell filled with a low...crossover connections are achieved by means of thick-film dielectric material. Chip components attached to the metallized substrate complete the circuits
CNES organization for station positioning of geostationary satellites
NASA Technical Reports Server (NTRS)
Dulac, Jean
1993-01-01
Since 1975, the Toulouse Space Centre (a technical establishment of the French Space Agency, CNES) has successfully brought 15 geostationary satellites on to station. During these 17 years of experience, an organization of human and material resources has been built up that ensures a very high level of reliability in the execution of these station positioning operations. The main characteristics of this organization are a rigourous definition of the roles and responsibilities of each person involved, very detailed operations documentation, and methodical preparation of the operations.
Protecting the entanglement of twisted photons by adaptive optics
NASA Astrophysics Data System (ADS)
Leonhard, Nina; Sorelli, Giacomo; Shatokhin, Vyacheslav N.; Reinlein, Claudia; Buchleitner, Andreas
2018-01-01
We study the efficiency of adaptive optics (AO) correction for the free-space propagation of entangled photonic orbital-angular-momentum (OAM) qubit states to reverse moderate atmospheric turbulence distortions. We show that AO can significantly reduce crosstalk to modes within and outside the encoding subspace and thereby stabilize entanglement against turbulence. This method establishes a reliable quantum channel for OAM photons in turbulence, and it enhances the threshold turbulence strength for secure quantum communication by at least a factor 2.
Air Force Manufacturing Technology Electronics Program, FY72-FY85.
1985-04-01
magnetic films of the composition Yl.52 EuO.30 TmO.30 CaO.88 Fe4.12 012 on 1.5 inch and 2.0 inch gadolinium gallium garnet substrates. Ten film were...volume manufacturing of hybrid MIC’s. A systematic integrated cost effective approach to testing, trimming/matching, fabri - cation, and assembly is...ESTABLISH MANUFACTURING METHODS FOR LOW COST HIGH RELIABILITY FABRI - CATION AND ACTIVATION OF OXIDE CATHODES FOR USE IN SPACE TRAVELING WAVE TUBES
Study of advanced techniques for determining the long-term performance of components
NASA Technical Reports Server (NTRS)
1972-01-01
A study was conducted of techniques having the capability of determining the performance and reliability of components for spacecraft liquid propulsion applications for long term missions. The study utilized two major approaches; improvement in the existing technology, and the evolution of new technology. The criteria established and methods evolved are applicable to valve components. Primary emphasis was placed on the propellants oxygen difluoride and diborane combination. The investigation included analysis, fabrication, and tests of experimental equipment to provide data and performance criteria.
A quick method for AlCu interconnect electromigration performance predicting and monitoring
NASA Astrophysics Data System (ADS)
Zhang, Wenjie; Yi, Leeward; Tao, Kai; Ma, Yue; Chang, Pingyi; Mao, Duli; Wu, Jin; Zou, S. C.
2006-05-01
The film properties and microstructures of (bottom)Si/SiO2/Ti(top) and (bottom)Si/SiO2/Ti/TiN/AlCu(top) stacks deposited by different processes were characterized. The resistivities of thin Ti films and the reflectivities of AlCu alloy films were found to correlate with the microstructure as well as the mean time to failure (MTTF) in the electromigration (EM) test. A quick-turn monitor for AlCu interconnect reliability in the semiconductor manufacturing industry was established.
Multiple attribute decision making model and application to food safety risk evaluation.
Ma, Lihua; Chen, Hong; Yan, Huizhe; Yang, Lifeng; Wu, Lifeng
2017-01-01
Decision making for supermarket food purchase decisions are characterized by network relationships. This paper analyzed factors that influence supermarket food selection and proposes a supplier evaluation index system based on the whole process of food production. The author established the intuitive interval value fuzzy set evaluation model based on characteristics of the network relationship among decision makers, and validated for a multiple attribute decision making case study. Thus, the proposed model provides a reliable, accurate method for multiple attribute decision making.
Bulk Fuel Pricing: DOD Needs to Take Additional Actions to Establish a More Reliable Methodology
2015-11-19
Page 1 GAO-16-78R Bulk Fuel Pricing 441 G St. N.W. Washington, DC 20548 November 19, 2015 The Honorable Ashton Carter The Secretary of...Defense Bulk Fuel Pricing : DOD Needs to Take Additional Actions to Establish a More Reliable Methodology Dear Secretary Carter: Each fiscal...year, the Office of the Under Secretary of Defense (Comptroller), in coordination with the Defense Logistics Agency, sets a standard price per barrel
Design of an audio advertisement dataset
NASA Astrophysics Data System (ADS)
Fu, Yutao; Liu, Jihong; Zhang, Qi; Geng, Yuting
2015-12-01
Since more and more advertisements swarm into radios, it is necessary to establish an audio advertising dataset which could be used to analyze and classify the advertisement. A method of how to establish a complete audio advertising dataset is presented in this paper. The dataset is divided into four different kinds of advertisements. Each advertisement's sample is given in *.wav file format, and annotated with a txt file which contains its file name, sampling frequency, channel number, broadcasting time and its class. The classifying rationality of the advertisements in this dataset is proved by clustering the different advertisements based on Principal Component Analysis (PCA). The experimental results show that this audio advertisement dataset offers a reliable set of samples for correlative audio advertisement experimental studies.
Wang, Jun; Zhou, Bihua; Zhou, Shudao
2016-01-01
This paper proposes an improved cuckoo search (ICS) algorithm to establish the parameters of chaotic systems. In order to improve the optimization capability of the basic cuckoo search (CS) algorithm, the orthogonal design and simulated annealing operation are incorporated in the CS algorithm to enhance the exploitation search ability. Then the proposed algorithm is used to establish parameters of the Lorenz chaotic system and Chen chaotic system under the noiseless and noise condition, respectively. The numerical results demonstrate that the algorithm can estimate parameters with high accuracy and reliability. Finally, the results are compared with the CS algorithm, genetic algorithm, and particle swarm optimization algorithm, and the compared results demonstrate the method is energy-efficient and superior. PMID:26880874
[Study on HPLC fingerprint of Alpinia officinarum].
Deng, Yi-Feng; Feng, Li-Na; Luo, Hui
2011-09-01
To establish the chromatography fingerprint of Alpinia officinarum by HPLC. An optimum HPLC conditions which were obtained under the assessment of LC-MS were as follows: Shim-pack VP-ODS column (2.0 mm x 250 mm, 5 microm), 0.1% HAc aqueous solution as phase A, 15% Acetonitrile: 40% Methanol: 45% Tetrafuran as phase B, the flow rate was 0.20 mL/min, column temperature was 35 degrees C and UV detector was set at 280 nm. The HPLC fingerprint of Alpinia officinarum was established, the consensus 10 peaks and their relative retention times along with the ranges of relative area were determined. The method is reliable and stable and can be used for the quality control and identification of Alpinia officinarum.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santos-Villalobos, Hector J; Barstow, Del R; Karakaya, Mahmut
Iris recognition has been proven to be an accurate and reliable biometric. However, the recognition of non-ideal iris images such as off angle images is still an unsolved problem. We propose a new biometric targeted eye model and a method to reconstruct the off-axis eye to its frontal view allowing for recognition using existing methods and algorithms. This allows for existing enterprise level algorithms and approaches to be largely unmodified by using our work as a pre-processor to improve performance. In addition, we describe the `Limbus effect' and its importance for an accurate segmentation of off-axis irides. Our method usesmore » an anatomically accurate human eye model and ray-tracing techniques to compute a transformation function, which reconstructs the iris to its frontal, non-refracted state. Then, the same eye model is used to render a frontal view of the reconstructed iris. The proposed method is fully described and results from synthetic data are shown to establish an upper limit on performance improvement and establish the importance of the proposed approach over traditional linear elliptical unwrapping methods. Our results with synthetic data demonstrate the ability to perform an accurate iris recognition with an image taken as much as 70 degrees off-axis.« less
Almeida, Gabriel Peixoto Leão; das Neves Rodrigues, Helena Larissa; de Freitas, Bruno Wesley; de Paula Lima, Pedro Olavo
2017-12-01
Study Design Cross-sectional study. Background The Hip Stability Isometric Test (HipSIT) evaluates the strength of the hip posterolateral stabilizers in a position that favors greater activation of the gluteus maximus and gluteus medius and lower activation of the tensor fascia lata. Objectives To check the validity and reliability of the HipSIT and to evaluate the HipSIT in women with patellofemoral pain (PFP). Methods The HipSIT was evaluated with a handheld dynamometer. During testing, the participants were sidelying, with their legs positioned at 45° of hip flexion and 90° of knee flexion. Participants were instructed to raise the knee of the upper leg while keeping the upper and lower heels in contact. To establish reliability and validity, 49 women were tested with the HipSIT by 2 different evaluators on day 1, and then again 7 days later. The strength of the hip extensors, abductors, and external rotators was also evaluated. Twenty women with unilateral PFP were also evaluated. Results The HipSIT has excellent intrarater and interrater reliability. The standard error of measurement was 0.01 kgf/kg, and the minimal detectable change was 0.036 kgf/kg. The HipSIT showed good validity in isolated hip abduction, external rotation, and extension (P<.01). Women with PFP showed a 10% deficit in the HipSIT results for the symptomatic limb (P = .01). Conclusion The HipSIT showed excellent interrater and intrarater reliability, moderate to good validity in women, and was able to identify strength deficits in women with PFP. J Orthop Sports Phys Ther 2017;47(12):906-913. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7274.
Frequency control of wind turbine in power system
NASA Astrophysics Data System (ADS)
Xu, Huawei
2018-06-01
In order to improve the stability of the overall frequency of the power system, automatic power generation control and secondary frequency adjustment were applied. Automatic power generation control was introduced into power generation planning. A dual-fed wind generator power regulation model suitable for secondary frequency regulation was established. The results showed that this method satisfied the basic requirements of frequency regulation control of large-scale wind power access power systems and improved the stability and reliability of power system operation. Therefore, this system frequency control method and strategy is relatively simple. The effect is significant. The system frequency can quickly reach a steady state. It is worth applying and promoting.
Modelling and management of subjective information in a fuzzy setting
NASA Astrophysics Data System (ADS)
Bouchon-Meunier, Bernadette; Lesot, Marie-Jeanne; Marsala, Christophe
2013-01-01
Subjective information is very natural for human beings. It is an issue at the crossroad of cognition, semiotics, linguistics, and psycho-physiology. Its management requires dedicated methods, among which we point out the usefulness of fuzzy and possibilistic approaches and related methods, such as evidence theory. We distinguish three aspects of subjectivity: the first deals with perception and sensory information, including the elicitation of quality assessment and the establishment of a link between physical and perceived properties; the second is related to emotions, their fuzzy nature, and their identification; and the last aspect stems from natural language and takes into account information quality and reliability of information.
Annual peak discharges from small drainage areas in Montana through September 1976
Johnson, M.V.; Omang, R.J.; Hull, J.A.
1977-01-01
Annual peak discharge from small drainage areas is tabulated for 336 sites in Montana. The 1976 additions included data collected at 206 sites. The program which investigates the magnitude and frequency of floods from small drainage areas in Montana, was begun July 1, 1955. Originally 45 crest-stage gaging stations were established. The purpose of the program is to collect sufficient peak-flow data, which through analysis could provide methods for estimating the magnitude and frequency of floods at any point in Montana. The ultimate objective is to provide methods for estimating the 100-year flood with the reliability needed for road design. (Woodard-USGS)
Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.
2010-01-01
The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208
Application Research of Fault Tree Analysis in Grid Communication System Corrective Maintenance
NASA Astrophysics Data System (ADS)
Wang, Jian; Yang, Zhenwei; Kang, Mei
2018-01-01
This paper attempts to apply the fault tree analysis method to the corrective maintenance field of grid communication system. Through the establishment of the fault tree model of typical system and the engineering experience, the fault tree analysis theory is used to analyze the fault tree model, which contains the field of structural function, probability importance and so on. The results show that the fault tree analysis can realize fast positioning and well repairing of the system. Meanwhile, it finds that the analysis method of fault tree has some guiding significance to the reliability researching and upgrading f the system.
Characteristics of the transmission loss apparatus at NASA Langley Research Center
NASA Technical Reports Server (NTRS)
Grosveld, F. W.
1983-01-01
A description of the Transmission Loss Apparatus at NASA Langley Research Center, which is specifically designed to accommodate general aviation type aircraft structures, is presented. The measurement methodology, referred to as the Plate Reference Method, is discussed and compared with the classical method as described in the Standard of the American Society for Testing and Materials. This measurement procedure enables reliable and accurate noise transmission loss measurements down to the 50 Hz one-third octave band. The transmission loss characteristics of add-on acoustical treatments, applied to the basic structure, can be established by inclusion of appropriate absorption corrections for the treatment.
The influence of liquidity on informational efficiency: The case of the Thai Stock Market
NASA Astrophysics Data System (ADS)
Bariviera, Aurelio Fernández
2011-11-01
The presence of long-range memory in financial time series is a puzzling fact that challenges the established financial theory. We study the effect of liquidity on the efficiency (measured by the Hurst’s exponent) of the Thai Stock Market. According to our study, we find that: (i) the R/S method could generate spurious long-range dependence, giving the DFA method more reliable estimates of the Hurst’s exponent and (ii) there is a weak relationship between market capitalization and the efficiency of the market, and that the latter is not significantly affected by the presence of foreign investors.
[Determination of protopine and isocorydine in root of Dactylicapnos scandens by HPLC].
Yan, Tian-qing; Yang, Yan-fang; Ai, Tie-min
2004-10-01
To establish a HPLC method for determination of protopine and isocorydine in root of Dactylicapnos scandens. The separation was performed in a PHENOMENEX-C18 column with a mobile phase of methanol-0.2% phosphoric acid (adjusted to pH 7.0 with triethylamine)(50:50), The detection wavelength was at 254 nm and the flow rate was 0.8 mL x min(-1). The average recovery of Protopine and Isocorydine was 97.9%, 98.6% respectively, and RSD 1.3%, 1.4%. This method is accurate, simple and reliable. It can be used for quality control of D. scandens.
18 CFR 39.10 - Changes to an Electric Reliability Organization Rule or Regional Entity Rule.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Changes to an Electric Reliability Organization Rule or Regional Entity Rule. 39.10 Section 39.10 Conservation of Power and Water... ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.10 Changes to an Electric...
18 CFR 39.10 - Changes to an Electric Reliability Organization Rule or Regional Entity Rule.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Changes to an Electric Reliability Organization Rule or Regional Entity Rule. 39.10 Section 39.10 Conservation of Power and Water... ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.10 Changes to an Electric...
18 CFR 39.10 - Changes to an Electric Reliability Organization Rule or Regional Entity Rule.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Changes to an Electric Reliability Organization Rule or Regional Entity Rule. 39.10 Section 39.10 Conservation of Power and Water... ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.10 Changes to an Electric...
18 CFR 39.10 - Changes to an Electric Reliability Organization Rule or Regional Entity Rule.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Changes to an Electric Reliability Organization Rule or Regional Entity Rule. 39.10 Section 39.10 Conservation of Power and Water... ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.10 Changes to an Electric...
Construction of Valid and Reliable Test for Assessment of Students
ERIC Educational Resources Information Center
Osadebe, P. U.
2015-01-01
The study was carried out to construct a valid and reliable test in Economics for secondary school students. Two research questions were drawn to guide the establishment of validity and reliability for the Economics Achievement Test (EAT). It is a multiple choice objective test of five options with 100 items. A sample of 1000 students was randomly…
Measuring the Nonviolent Tendencies of College Students.
ERIC Educational Resources Information Center
Mayton, Daniel M., II; Richel, Timothy W.; Susnjic, Silvia; Majdanac, Maja
The Teenage Nonviolence Test (TNT) has previously been established as a generally reliable and valid measure of nonviolence in adolescents. This study examined the extent to which the TNT's reliability and validity could be extended to college students aged 18-22 years of age. Five of the six subscales of the TNT were found to be reliable. The…
Validity and Reliability of the Arabic Token Test for Children
ERIC Educational Resources Information Center
Alkhamra, Rana A.; Al-Jazi, Aya B.
2016-01-01
Background: The Token Test for Children (2nd edition) (TTFC) is a measure for assessing receptive language. In this study we describe the translation process, validity and reliability of the Arabic Token Test for Children (A-TTFC). Aims: The aim of this study is to translate, validate and establish the reliability of the Arabic Token Test for…
Development and evaluation of a patient-centred measurement tool for surgeons' non-technical skills.
Yule, J; Hill, K; Yule, S
2018-06-01
Non-technical skills are essential for safe and effective surgery. Several tools to assess surgeons' non-technical skills from the clinician's perspective have been developed. However, a reliable measurement tool using a patient-centred approach does not currently exist. The aim of this study was to translate the existing Non-Technical Skills for Surgeons (NOTSS) tool into a patient-centred evaluation tool. Data were gathered from four cohorts of patients using an iterative four-stage mixed-methods research design. Exploratory and confirmatory factor analyses were performed to establish the psychometric properties of the tool, focusing on validity, reliability, usability and parsimony. Some 534 patients were recruited to the study. A total of 24 patient-centred non-technical skill items were developed in stage 1, and reduced to nine items in stage 2 using exploratory factor analysis. In stage 3, confirmatory factor analysis demonstrated that these nine items each loaded on to one of three factors, with excellent internal consistency: decision-making, leadership, and communication and teamwork. In stage 4, validity testing established that the new tool was independent of physician empathy and predictive of surgical quality. Surgical leadership emerged as the most dominant skill that patients could recognize and evaluate. A novel nine-item assessment tool has been developed. The Patients' Evaluation of Non-Technical Skills (PENTS) tool allows valid and reliable measurement of surgeons' non-technical skills from the patient perspective. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.
Benavides, Francisco D; Santamaria, Andrea J; Bodoukhin, Nikita; Guada, Luis G; Solano, Juan P; Guest, James D
2017-09-15
Yucatan micropigs have brain and spinal cord dimensions similar to humans and are useful for certain spinal cord injury (SCI) translational studies. Micropigs are readily trained in behavioral tasks, allowing consistent testing of locomotor loss and recovery. However, there has been little description of their motor and sensory pathway neurophysiology. We established methods to assess motor and sensory cortical evoked potentials in the anesthetized, uninjured state. We also evaluated epidurally evoked motor and sensory stimuli from the T6 and T9 levels, spanning the intended contusion injury epicenter. Response detection frequency, mean latency and amplitude values, and variability of evoked potentials were determined. Somatosensory evoked potentials were reliable and best detected during stimulation of peripheral nerve and epidural stimulation by referencing the lateral cortex to midline Fz. The most reliable hindlimb motor evoked potential (MEP) occurred in tibialis anterior. We found MEPs in forelimb muscles in response to thoracic epidural stimulation likely generated from propriospinal pathways. Cranially stimulated MEPs were easier to evoke in the upper limbs than in the hindlimbs. Autopsy studies revealed substantial variations in cortical morphology between animals. This electrophysiological study establishes that neurophysiological measures can be reliably obtained in micropigs in a time frame compatible with other experimental procedures, such as SCI and transplantation. It underscores the need to better understand the motor control pathways, including the corticospinal tract, to determine which therapeutics are suitable for testing in the pig model.
The TiltMeter app is a novel and accurate measurement tool for the weight bearing lunge test.
Williams, Cylie M; Caserta, Antoni J; Haines, Terry P
2013-09-01
The weight bearing lunge test is increasing being used by health care clinicians who treat lower limb and foot pathology. This measure is commonly established accurately and reliably with the use of expensive equipment. This study aims to compare the digital inclinometer with a free app, TiltMeter on an Apple iPhone. This was an intra-rater and inter-rater reliability study. Two raters (novice and experienced) conducted the measurements in both a bent knee and straight leg position to determine the intra-rater and inter-rater reliability. Concurrent validity was also established. Allied health practitioners were recruited as participants from the workplace. A preconditioning stretch was conducted and the ankle range of motion was established with the weight bearing lunge test position with firstly the leg straight and secondly with the knee bent. The measurement device and each participant were randomised during measurement. The intra-rater reliability and inter-rater reliability for the devices and in both positions were all over ICC 0.8 except for one intra-rater measure (Digital inclinometer, novice, ICC 0.65). The inter-rater reliability between the digital inclinometer and the tilmeter was near perfect, ICC 0.96 (CI: 0.898-0.983); Concurrent validity ICC between the two devices was 0.83 (CI: -0.740 to 0.445). The use of the Tiltmeter app on the iPhone is a reliable and inexpensive tool to measure the available ankle range of motion. Health practitioners should use caution in applying these findings to other smart phone equipment if surface areas are not comparable. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Stolinski, L; Kozinoga, M; Czaprowski, D; Tyrakowski, M; Cerny, P; Suzuki, N; Kotwicki, T
2017-01-01
Digital photogrammetry provides measurements of body angles or distances which allow for quantitative posture assessment with or without the use of external markers. It is becoming an increasingly popular tool for the assessment of the musculoskeletal system. The aim of this paper is to present a structured method for the analysis of posture and its changes using a standardized digital photography technique. The purpose of the study was twofold. The first one comprised 91 children (44 girls and 47 boys) aged 7-10 (8.2 ± 1.0), i.e., students of primary school, and its aim was to develop the photographic method, choose the quantitative parameters, and determine the intraobserver reliability (repeatability) along with the interobserver reliability (reproducibility) measurements in sagittal plane using digital photography, as well as to compare the Rippstein plurimeter and digital photography measurements. The second one involved 7782 children (3804 girls, 3978 boys) aged 7-10 (8.4 ± 0.5), who underwent digital photography postural screening. The methods consisted in measuring and calculating selected parameters, establishing the normal ranges of photographic parameters, presenting percentile charts, as well as noticing common pitfalls and possible sources of errors in digital photography. A standardized procedure for the photographic evaluation of child body posture was presented. The photographic measurements revealed very good intra- and inter-rater reliability regarding the five sagittal parameters and good reliability performed against Rippstein plurimeter measurements. The parameters displayed insignificant variability over time. Normative data were calculated based on photographic assessment, while the percentile charts were provided to serve as reference values. The technical errors observed during photogrammetry are carefully discussed in this article. Technical developments are allowed for the regular use of digital photogrammetry in body posture assessment. Specific child positioning (described above) enables us to avoid incidentally modified posture. Image registration is simple, quick, harmless, and cost-effective. The semi-automatic image analysis, together with the normal values and percentile charts, makes the technique reliable in terms of child's posture documentation and corrective therapy effects' monitoring.
75 FR 72664 - System Personnel Training Reliability Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-26
...Under section 215 of the Federal Power Act, the Commission approves two Personnel Performance, Training and Qualifications (PER) Reliability Standards, PER-004-2 (Reliability Coordination--Staffing) and PER-005-1 (System Personnel Training), submitted to the Commission for approval by the North American Electric Reliability Corporation, the Electric Reliability Organization certified by the Commission. The approved Reliability Standards require reliability coordinators, balancing authorities, and transmission operators to establish a training program for their system operators, verify each of their system operators' capability to perform tasks, and provide emergency operations training to every system operator. The Commission also approves NERC's proposal to retire two existing PER Reliability Standards that are replaced by the standards approved in this Final Rule.
Zarkovic, Andrea; Mora, Justin; McKelvie, James; Gamble, Greg
2007-12-01
The aim of the study was to establish the correlation between visual filed loss as shown by second-generation Frequency Doubling Technology (Humphrey Matrix) and Standard Automated Perimetry (Humphrey Field Analyser) in patients with glaucoma. Also, compared were the test duration and reliability. Forty right eyes from glaucoma patients from a private ophthalmology practice were included in this prospective study. All participants had tests within an 8-month period. Pattern deviation plots and mean deviation were compared to establish the correlation between the two perimetry tests. Overall correlation and correlation between hemifields, quadrants and individual test locations were assessed. Humphrey Field Analyser tests were slightly more reliable (37/40 vs. 34/40 for Matrix)) but overall of longer duration. There was good correlation (0.69) between mean deviations. Superior hemifields and superonasal quadrants had the highest correlation (0.88 [95% CI 0.79, 0.94]). Correlation between individual points was independent of distance from the macula. Generally, the Matrix and Humphrey Field Analyser perimetry correlate well; however, each machine utilizes a different method of analysing data and thus the direct comparison should be made with caution.
Methods for determining time of death.
Madea, Burkhard
2016-12-01
Medicolegal death time estimation must estimate the time since death reliably. Reliability can only be provided empirically by statistical analysis of errors in field studies. Determining the time since death requires the calculation of measurable data along a time-dependent curve back to the starting point. Various methods are used to estimate the time since death. The current gold standard for death time estimation is a previously established nomogram method based on the two-exponential model of body cooling. Great experimental and practical achievements have been realized using this nomogram method. To reduce the margin of error of the nomogram method, a compound method was developed based on electrical and mechanical excitability of skeletal muscle, pharmacological excitability of the iris, rigor mortis, and postmortem lividity. Further increasing the accuracy of death time estimation involves the development of conditional probability distributions for death time estimation based on the compound method. Although many studies have evaluated chemical methods of death time estimation, such methods play a marginal role in daily forensic practice. However, increased precision of death time estimation has recently been achieved by considering various influencing factors (i.e., preexisting diseases, duration of terminal episode, and ambient temperature). Putrefactive changes may be used for death time estimation in water-immersed bodies. Furthermore, recently developed technologies, such as H magnetic resonance spectroscopy, can be used to quantitatively study decompositional changes. This review addresses the gold standard method of death time estimation in forensic practice and promising technological and scientific developments in the field.
Thomas, Krista; Wechsler, Dominik; Chen, Yi-Min; Crain, Sheila; Quilliam, Michael A
2016-09-01
The implementation of instrumental analytical methods such as LC-MS for routine monitoring of toxins requires the availability of accurate calibration standards. This is a challenge because many toxins are rare, expensive, dangerous to handle, and/or unstable, and simple gravimetric procedures are not reliable for establishing accurate concentrations in solution. NMR has served as one method of qualitative and quantitative characterization of toxin calibration solution Certified Reference Materials (CRMs). LC with chemiluminescence N detection (LC-CLND) was selected as a complementary method for comprehensive characterization of CRMs because it provides a molar response to N. Here we report on our investigation of LC-CLND as a method suitable for quantitative analysis of nitrogenous toxins. It was demonstrated that a wide range of toxins could be analyzed quantitatively by LC-CLND. Furthermore, equimolar responses among diverse structures were established and it was shown that a single high-purity standard such as caffeine could be used for instrument calibration. The limit of detection was approximately 0.6 ng N. Measurement of several of Canada's National Research Council toxin CRMs with caffeine as the calibrant showed precision averaging 2% RSD and accuracy ranging from 97 to 102%. Application of LC-CLND to the production of calibration solution CRMs and the establishment of traceability of measurement results are presented.
Establishing the validity and reliability of the Project Talent Personality Inventory
Pozzebon, Julie; Damian, Rodica I.; Hill, Patrick L.; Lin, Yuchen; Lapham, Susan; Roberts, Brent W.
2013-01-01
Project Talent is a national longitudinal study that started in 1960. The original sample included over 440,000 students, which amounted to a 5% representative sample of high school students across the United States. Previous research has not yet established the validity and reliability of the personality measure used in this study, that is, the Project Talent Personality Inventory (PTPI). Given the potential interest and use of the PTPI in forthcoming research, the goals of the present paper were to establish (a) the construct and predictive validity and (b) the internal consistency and test-retest reliability of the PTPI. This information will be valuable to researchers who might be interested in using the PTPI to predict life course outcomes, such as mortality, occupational success, relationship success, and health. Study 1 found that the 10 sub-scales of the PTPI showed good internal consistency reliability, as well as good construct and predictive validity. With the use of several modern personality measures, we showed how the 10 PTPI scales can be mapped onto the Big Five personality traits, and we examined their relations with health, well-being, and life satisfaction outcomes. Study 2 found that the 10 PTPI scales showed good test-retest reliability. Together, these findings allow researchers to better understand and use the PTPI scales, as they are available in Project Talent. PMID:24399984
How reliable are clinical systems in the UK NHS? A study of seven NHS organisations
Franklin, Bryony Dean; Moorthy, Krishna; Cooke, Matthew W; Vincent, Charles
2012-01-01
Background It is well known that many healthcare systems have poor reliability; however, the size and pervasiveness of this problem and its impact has not been systematically established in the UK. The authors studied four clinical systems: clinical information in surgical outpatient clinics, prescribing for hospital inpatients, equipment in theatres, and insertion of peripheral intravenous lines. The aim was to describe the nature, extent and variation in reliability of these four systems in a sample of UK hospitals, and to explore the reasons for poor reliability. Methods Seven UK hospital organisations were involved; each system was studied in three of these. The authors took delivery of the systems' intended outputs to be a proxy for the reliability of the system as a whole. For example, for clinical information, 100% reliability was defined as all patients having an agreed list of clinical information available when needed during their appointment. Systems factors were explored using semi-structured interviews with key informants. Common themes across the systems were identified. Results Overall reliability was found to be between 81% and 87% for the systems studied, with significant variation between organisations for some systems: clinical information in outpatient clinics ranged from 73% to 96%; prescribing for hospital inpatients 82–88%; equipment availability in theatres 63–88%; and availability of equipment for insertion of peripheral intravenous lines 80–88%. One in five reliability failures were associated with perceived threats to patient safety. Common factors causing poor reliability included lack of feedback, lack of standardisation, and issues such as access to information out of working hours. Conclusions Reported reliability was low for the four systems studied, with some common factors behind each. However, this hides significant variation between organisations for some processes, suggesting that some organisations have managed to create more reliable systems. Standardisation of processes would be expected to have significant benefit. PMID:22495099
Inter-rater reliability of malaria parasite counts and comparison of methods
2009-01-01
Background The introduction of artemesinin-based treatment for falciparum malaria has led to a shift away from symptom-based diagnosis. Diagnosis may be achieved by using rapid non-microscopic diagnostic tests (RDTs), of which there are many available. Light microscopy, however, has a central role in parasite identification and quantification and remains the main method of parasite-based diagnosis in clinic and hospital settings and is necessary for monitoring the accuracy of RDTs. The World Health Organization has prepared a proficiency testing panel containing a range of malaria-positive blood samples of known parasitaemia, to be used for the assessment of commercially available malaria RDTs. Different blood film and counting methods may be used for this purpose, which raises questions regarding accuracy and reproducibility. A comparison was made of the established methods for parasitaemia estimation to determine which would give the least inter-rater and inter-method variation Methods Experienced malaria microscopists counted asexual parasitaemia on different slides using three methods; the thin film method using the total erythrocyte count, the thick film method using the total white cell count and the Earle and Perez method. All the slides were stained using Giemsa pH 7.2. Analysis of variance (ANOVA) models were used to find the inter-rater reliability for the different methods. The paired t-test was used to assess any systematic bias between the two methods, and a regression analysis was used to see if there was a changing bias with parasite count level. Results The thin blood film gave parasite counts around 30% higher than those obtained by the thick film and Earle and Perez methods, but exhibited a loss of sensitivity with low parasitaemia. The thick film and Earle and Perez methods showed little or no bias in counts between the two methods, however, estimated inter-rater reliability was slightly better for the thick film method. Conclusion The thin film method gave results closer to the true parasite count but is not feasible at a parasitaemia below 500 parasites per microlitre. The thick film method was both reproducible and practical for this project. The determination of malarial parasitaemia must be applied by skilled operators using standardized techniques. PMID:19939271
Illustrated structural application of universal first-order reliability method
NASA Technical Reports Server (NTRS)
Verderaime, V.
1994-01-01
The general application of the proposed first-order reliability method was achieved through the universal normalization of engineering probability distribution data. The method superimposes prevailing deterministic techniques and practices on the first-order reliability method to surmount deficiencies of the deterministic method and provide benefits of reliability techniques and predictions. A reliability design factor is derived from the reliability criterion to satisfy a specified reliability and is analogous to the deterministic safety factor. Its application is numerically illustrated on several practical structural design and verification cases with interesting results and insights. Two concepts of reliability selection criteria are suggested. Though the method was developed to support affordable structures for access to space, the method should also be applicable for most high-performance air and surface transportation systems.
Murray, Nicholas P.; Hunfalvay, Melissa; Bolte, Takumi
2017-01-01
Purpose The purpose of this study was to determine the reliability of interpupillary distance (IPD) and pupil diameter (PD) measures using an infrared eye tracker and central point stimuli. Validity of the test compared to known clinical tools was determined, and normative data was established against which individuals can measure themselves. Methods Participants (416) across various demographics were examined for normative data. Of these, 50 were examined for reliability and validity. Validity for IPD measured the test (RightEye IPD/PD) against the PL850 Pupilometer and the Essilor Digital CRP. For PD, the test was measured against the Rosenbaum Pocket Vision Screener (RPVS). Reliability was analyzed with intraclass correlation coefficients (ICC) between trials with Cronbach's alpha (CA) and the standard error of measurement for each ICC. Convergent validity was investigated by calculating the bivariate correlation coefficient. Results Reliability results were strong (CA > 0.7) for all measures. High positive significant correlations were found between the RightEye IPD test and the PL850 Pupilometer (P < 0.001) and Essilor Digital CRP (P < 0.001) and for the RightEye PD test and the RPVS (P < 0.001). Conclusions Using infrared eye tracking and the RightEye IPD/PD test stimuli, reliable and accurate measures of IPD and PD were found. Results from normative data showed an adequate comparison for people with normal vision development. Translational Relevance Results revealed a central point of fixation may remove variability in examining PD reliably using infrared eye tracking when consistent environmental and experimental procedures are conducted. PMID:28685104
An Evaluation Method of Equipment Reliability Configuration Management
NASA Astrophysics Data System (ADS)
Wang, Wei; Feng, Weijia; Zhang, Wei; Li, Yuan
2018-01-01
At present, many equipment development companies have been aware of the great significance of reliability of the equipment development. But, due to the lack of effective management evaluation method, it is very difficult for the equipment development company to manage its own reliability work. Evaluation method of equipment reliability configuration management is to determine the reliability management capabilities of equipment development company. Reliability is not only designed, but also managed to achieve. This paper evaluates the reliability management capabilities by reliability configuration capability maturity model(RCM-CMM) evaluation method.
Constructing the "Best" Reliability Data for the Job
NASA Technical Reports Server (NTRS)
DeMott, D. L.; Kleinhammer, R. K.
2014-01-01
Modern business and technical decisions are based on the results of analyses. When considering assessments using "reliability data", the concern is how long a system will continue to operate as designed. Generally, the results are only as good as the data used. Ideally, a large set of pass/fail tests or observations to estimate the probability of failure of the item under test would produce the best data. However, this is a costly endeavor if used for every analysis and design. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, we attempt to develop the "best" or composite analog data to support our assessments. One method used incorporates processes for reviewing existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. Data that is more representative of reality and more project specific would provide more accurate analysis, and hopefully a better final decision.
Constructing the Best Reliability Data for the Job
NASA Technical Reports Server (NTRS)
Kleinhammer, R. K.; Kahn, J. C.
2014-01-01
Modern business and technical decisions are based on the results of analyses. When considering assessments using "reliability data", the concern is how long a system will continue to operate as designed. Generally, the results are only as good as the data used. Ideally, a large set of pass/fail tests or observations to estimate the probability of failure of the item under test would produce the best data. However, this is a costly endeavor if used for every analysis and design. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, we attempt to develop the "best" or composite analog data to support our assessments. One method used incorporates processes for reviewing existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. Data that is more representative of reality and more project specific would provide more accurate analysis, and hopefully a better final decision.
Taguchi Approach to Design Optimization for Quality and Cost: An Overview
NASA Technical Reports Server (NTRS)
Unal, Resit; Dean, Edwin B.
1990-01-01
Calibrations to existing cost of doing business in space indicate that to establish human presence on the Moon and Mars with the Space Exploration Initiative (SEI) will require resources, felt by many, to be more than the national budget can afford. In order for SEI to succeed, we must actually design and build space systems at lower cost this time, even with tremendous increases in quality and performance requirements, such as extremely high reliability. This implies that both government and industry must change the way they do business. Therefore, new philosophy and technology must be employed to design and produce reliable, high quality space systems at low cost. In recognizing the need to reduce cost and improve quality and productivity, Department of Defense (DoD) and National Aeronautics and Space Administration (NASA) have initiated Total Quality Management (TQM). TQM is a revolutionary management strategy in quality assurance and cost reduction. TQM requires complete management commitment, employee involvement, and use of statistical tools. The quality engineering methods of Dr. Taguchi, employing design of experiments (DOE), is one of the most important statistical tools of TQM for designing high quality systems at reduced cost. Taguchi methods provide an efficient and systematic way to optimize designs for performance, quality, and cost. Taguchi methods have been used successfully in Japan and the United States in designing reliable, high quality products at low cost in such areas as automobiles and consumer electronics. However, these methods are just beginning to see application in the aerospace industry. The purpose of this paper is to present an overview of the Taguchi methods for improving quality and reducing cost, describe the current state of applications and its role in identifying cost sensitive design parameters.
Requirements for Printed Wiring Boards
NASA Technical Reports Server (NTRS)
1984-01-01
In order to maintain the high standards of the NASA printed wiring programs, this publication: prescribes NASA's requirements for assuring reliable rigid printed wiring boards; describes and incorporates basic considerations necessary to assure reliable rigid printed wiring boards; establishes the supplier's responsibility to train and certify personnel; provides for supplier documentation of the fabrication and inspection procedures to be used for NASA work, including supplier innovations and changes in technology; and provides visual workmanship standards to aid those responsible for determining quality conformance to the established requirements.
Molecular differentiation of Russian wild ginseng using mitochondrial nad7 intron 3 region.
Li, Guisheng; Cui, Yan; Wang, Hongtao; Kwon, Woo-Saeng; Yang, Deok-Chun
2017-07-01
Cultivated ginseng is often introduced as a substitute and adulterant of Russian wild ginseng due to its lower cost or misidentification caused by similarity in appearance with wild ginseng. The aim of this study is to develop a simple and reliable method to differentiate Russian wild ginseng from cultivated ginseng. The mitochondrial NADH dehydrogenase subunit 7 ( nad 7) intron 3 regions of Russian wild ginseng and Chinese cultivated ginseng were analyzed. Based on the multiple sequence alignment result, a specific primer for Russian wild ginseng was designed by introducing additional mismatch and allele-specific polymerase chain reaction (PCR) was performed for identification of wild ginseng. Real-time allele-specific PCR with endpoint analysis was used for validation of the developed Russian wild ginseng single nucleotide polymorphism (SNP) marker. An SNP site specific to Russian wild ginseng was exploited by multiple alignments of mitochondrial nad 7 intron 3 regions of different ginseng samples. With the SNP-based specific primer, Russian wild ginseng was successfully discriminated from Chinese and Korean cultivated ginseng samples by allele-specific PCR. The reliability and specificity of the SNP marker was validated by checking 20 individuals of Russian wild ginseng samples with real-time allele-specific PCR assay. An effective DNA method for molecular discrimination of Russian wild ginseng from Chinese and Korean cultivated ginseng was developed. The established real-time allele-specific PCR was simple and reliable, and the present method should be a crucial complement of chemical analysis for authentication of Russian wild ginseng.
NASA Astrophysics Data System (ADS)
Hardikar, Kedar Y.; Liu, Bill J. J.; Bheemreddy, Venkata
2016-09-01
Gaining an understanding of degradation mechanisms and their characterization are critical in developing relevant accelerated tests to ensure PV module performance warranty over a typical lifetime of 25 years. As newer technologies are adapted for PV, including new PV cell technologies, new packaging materials, and newer product designs, the availability of field data over extended periods of time for product performance assessment cannot be expected within the typical timeframe for business decisions. In this work, to enable product design decisions and product performance assessment for PV modules utilizing newer technologies, Simulation and Mechanism based Accelerated Reliability Testing (SMART) methodology and empirical approaches to predict field performance from accelerated test results are presented. The method is demonstrated for field life assessment of flexible PV modules based on degradation mechanisms observed in two accelerated tests, namely, Damp Heat and Thermal Cycling. The method is based on design of accelerated testing scheme with the intent to develop relevant acceleration factor models. The acceleration factor model is validated by extensive reliability testing under different conditions going beyond the established certification standards. Once the acceleration factor model is validated for the test matrix a modeling scheme is developed to predict field performance from results of accelerated testing for particular failure modes of interest. Further refinement of the model can continue as more field data becomes available. While the demonstration of the method in this work is for thin film flexible PV modules, the framework and methodology can be adapted to other PV products.
Study on validation method for femur finite element model under multiple loading conditions
NASA Astrophysics Data System (ADS)
Guan, Fengjiao; Zhang, Guanjun; Liu, Jie; Wang, Shujing; Luo, Xu
2018-03-01
Acquisition of accurate and reliable constitutive parameters related to bio-tissue materials was beneficial to improve biological fidelity of a Finite Element (FE) model and predict impact damages more effectively. In this paper, a femur FE model was established under multiple loading conditions with diverse impact positions. Then, based on sequential response surface method and genetic algorithms, the material parameters identification was transformed to a multi-response optimization problem. Finally, the simulation results successfully coincided with force-displacement curves obtained by numerous experiments. Thus, computational accuracy and efficiency of the entire inverse calculation process were enhanced. This method was able to effectively reduce the computation time in the inverse process of material parameters. Meanwhile, the material parameters obtained by the proposed method achieved higher accuracy.
NASA Astrophysics Data System (ADS)
Tiwari, Harinarayan; Sharma, Nayan
2017-05-01
This research paper focuses on the need of turbulence, instruments reliable to capture turbulence, different turbulence parameters and some advance methodology which can decompose various turbulence structures at different levels near hydraulic structures. Small-scale turbulence research has valid prospects in open channel flow. The relevance of the study is amplified as we introduce any hydraulic structure in the channel which disturbs the natural flow and creates discontinuity. To recover this discontinuity, the piano key weir (PKW) might be used with sloped keys. Constraints of empirical results in the vicinity of PKW necessitate extensive laboratory experiments with fair and reliable instrumentation techniques. Acoustic Doppler velocimeter was established to be best suited within range of some limitations using principal component analysis. Wavelet analysis is proposed to decompose the underlying turbulence structure in a better way.
Wei, Wenhui; Gao, Zhaohui; Gao, Shesheng; Jia, Ke
2018-01-01
In order to meet the requirements of autonomy and reliability for the navigation system, combined with the method of measuring speed by using the spectral redshift information of the natural celestial bodies, a new scheme, consisting of Strapdown Inertial Navigation System (SINS)/Spectral Redshift (SRS)/Geomagnetic Navigation System (GNS), is designed for autonomous integrated navigation systems. The principle of this SINS/SRS/GNS autonomous integrated navigation system is explored, and the corresponding mathematical model is established. Furthermore, a robust adaptive central difference particle filtering algorithm is proposed for this autonomous integrated navigation system. The simulation experiments are conducted and the results show that the designed SINS/SRS/GNS autonomous integrated navigation system possesses good autonomy, strong robustness and high reliability, thus providing a new solution for autonomous navigation technology. PMID:29642549
Impact of identity theft on methods of identification.
McLemore, Jerri; Hodges, Walker; Wyman, Amy
2011-06-01
Responsibility for confirming a decedent's identity commonly falls on the shoulders of the coroner or medical examiner. Misidentification of bodies results in emotional turmoil for the next-of-kin and can negatively impact the coroner's or medical examiner's career. To avoid such mishaps, the use of scientific methods to establish a positive identification is advocated. The use of scientific methods of identification may not be reliable in cases where the decedent had assumed the identity of another person. Case studies of erroneously identified bodies due to identity theft from the state medical examiner offices in Iowa and New Mexico are presented. This article discusses the scope and major concepts of identity theft and how identity theft prevents the guarantee of a positive identification.
Simulation Study on the Deflection Response of the 921A Steel thin plate under Explosive Impact Load
NASA Astrophysics Data System (ADS)
Zhang, Yu-Xiang; Chen, Fang; Han, Yan
2018-03-01
The Ship cabin would be subject to high-intensity shock wave load when it is attacked by anti-ship weapons, causing its side board damaged. The time course of the deflection of the thin plate made of 921A steel in different initial conditions under the impact load is researched by theoretical analysis and numerical simulation. According to the theory of elastic-plastic deformation of the thin plate, the dynamic response equation of the thin plate under the explosion impact load is established with the method of energy, and the theoretical calculation value is compared with the result from the simulation method. It proved that the theoretical calculation method has better reliability and accuracy in different boundary size.
Intracranial Pressure Monitoring—Review and Avenues for Development
Dolmans, Rianne G. F.
2018-01-01
Intracranial pressure (ICP) monitoring is a staple of neurocritical care. The most commonly used current methods of monitoring in the acute setting include fluid-based systems, implantable transducers and Doppler ultrasonography. It is well established that management of elevated ICP is critical for clinical outcomes. However, numerous studies show that current methods of ICP monitoring cannot reliably define the limit of the brain’s intrinsic compensatory capacity to manage increases in pressure, which would allow for proactive ICP management. Current work in the field hopes to address this gap by harnessing live-streaming ICP pressure-wave data and a multimodal integration with other physiologic measures. Additionally, there is continued development of non-invasive ICP monitoring methods for use in specific clinical scenarios. PMID:29401746
Laser Doppler vibrometry: new ENT applications
NASA Astrophysics Data System (ADS)
Stasche, Norbert; Baermann, M.; Kempe, C.; Hoermann, Karl; Foth, Hans-Jochen
1996-12-01
Common audiometry often does not really allow a reliable and objective differential diagnosis of hearing disorders such as otosclerosis, adhesive otitis, ossicular interruption or tinnitus, even though several methods might be used complementarily. In recent years, some experimental studies on middle ear mechanics established laser Doppler vibrometry (LDV) as a useful method allowing objective measurement of human tympanic membrane displacement. The present study on LDV investigated the clinical use of this new method under physiological conditions. LDV proved to be a fast, reproducible, non-invasive and very sensitive instrument to characterize ear-drum vibrations in various middle ear dysfunctions, except in tinnitus patients. For future applications, improved optical characteristics of the vibrometer might result in a better differential diagnosis of subjective and objective tinnitus, otoacoustic emissions or Morbus Meniere.
The reliability paradox: Why robust cognitive tasks do not produce reliable individual differences.
Hedge, Craig; Powell, Georgina; Sumner, Petroc
2018-06-01
Individual differences in cognitive paradigms are increasingly employed to relate cognition to brain structure, chemistry, and function. However, such efforts are often unfruitful, even with the most well established tasks. Here we offer an explanation for failures in the application of robust cognitive paradigms to the study of individual differences. Experimental effects become well established - and thus those tasks become popular - when between-subject variability is low. However, low between-subject variability causes low reliability for individual differences, destroying replicable correlations with other factors and potentially undermining published conclusions drawn from correlational relationships. Though these statistical issues have a long history in psychology, they are widely overlooked in cognitive psychology and neuroscience today. In three studies, we assessed test-retest reliability of seven classic tasks: Eriksen Flanker, Stroop, stop-signal, go/no-go, Posner cueing, Navon, and Spatial-Numerical Association of Response Code (SNARC). Reliabilities ranged from 0 to .82, being surprisingly low for most tasks given their common use. As we predicted, this emerged from low variance between individuals rather than high measurement variance. In other words, the very reason such tasks produce robust and easily replicable experimental effects - low between-participant variability - makes their use as correlational tools problematic. We demonstrate that taking such reliability estimates into account has the potential to qualitatively change theoretical conclusions. The implications of our findings are that well-established approaches in experimental psychology and neuropsychology may not directly translate to the study of individual differences in brain structure, chemistry, and function, and alternative metrics may be required.
Ernst, D; Clerc, J; Decullier, E; Gavanier, G; Dupuis, O
2012-10-01
At birth, evaluation of neonatal well-being is crucial. It is though important to perform umbilical cord blood gas analysis, and then to analyze the samples. We wanted to establish the feasibility and reliability of systematic umbilical cord blood sampling in a French labour ward. Study of systematic umbilical cord blood gas analysis was realized retrospectively from 1000 consecutive deliveries. We first established the feasibility of the samples. Feasibility was defined by the ratio of complete cord acid-base data on the number of deliveries from alive newborns. Afterwards, we established the reliability on the remaining cord samples. Reliability was the ratio of samples that fulfilled quality criteria defined by Westgate et al. and revised by Kro et al., on the number of complete samples from alive newborns. At last, we looked for factors that would influence these results. The systematic umbilical cord blood sample feasibility reached 91.6%, and the reliability reached 80.7%. About the delivery mode, 38.6% of emergency caesarians (IC 95% [30.8-46.3]; P<0.0001) led to non-valid samples, when only 11.3% of programmed caesarians (IC 95% [4.3-18.2]; P<0.0001) led to non-valid samples. Umbilical cord blood analysis were significantly less validated during emergency caesarians. Realization of systematic cord blood gas analysis was followed by 8.4% of incomplete samples, and by 19.3% that were uninterpretable. Training sessions should be organized to improve the feasibility and reliability, especially during emergency caesarians. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
A new compound control method for sine-on-random mixed vibration test
NASA Astrophysics Data System (ADS)
Zhang, Buyun; Wang, Ruochen; Zeng, Falin
2017-09-01
Vibration environmental test (VET) is one of the important and effective methods to provide supports for the strength design, reliability and durability test of mechanical products. A new separation control strategy was proposed to apply in multiple-input multiple-output (MIMO) sine on random (SOR) mixed mode vibration test, which is the advanced and intensive test type of VET. As the key problem of the strategy, correlation integral method was applied to separate the mixed signals which included random and sinusoidal components. The feedback control formula of MIMO linear random vibration system was systematically deduced in frequency domain, and Jacobi control algorithm was proposed in view of the elements, such as self-spectrum, coherence, and phase of power spectral density (PSD) matrix. Based on the excessive correction of excitation in sine vibration test, compression factor was introduced to reduce the excitation correction, avoiding the destruction to vibration table or other devices. The two methods were synthesized to be applied in MIMO SOR vibration test system. In the final, verification test system with the vibration of a cantilever beam as the control object was established to verify the reliability and effectiveness of the methods proposed in the paper. The test results show that the exceeding values can be controlled in the tolerance range of references accurately, and the method can supply theory and application supports for mechanical engineering.
A Study on Micropipetting Detection Technology of Automatic Enzyme Immunoassay Analyzer.
Shang, Zhiwu; Zhou, Xiangping; Li, Cheng; Tsai, Sang-Bing
2018-04-10
In order to improve the accuracy and reliability of micropipetting, a method of micro-pipette detection and calibration combining the dynamic pressure monitoring in pipetting process and quantitative identification of pipette volume in image processing was proposed. Firstly, the normalized pressure model for the pipetting process was established with the kinematic model of the pipetting operation, and the pressure model is corrected by the experimental method. Through the pipetting process pressure and pressure of the first derivative of real-time monitoring, the use of segmentation of the double threshold method as pipetting fault evaluation criteria, and the pressure sensor data are processed by Kalman filtering, the accuracy of fault diagnosis is improved. When there is a fault, the pipette tip image is collected through the camera, extract the boundary of the liquid region by the background contrast method, and obtain the liquid volume in the tip according to the geometric characteristics of the pipette tip. The pipette deviation feedback to the automatic pipetting module and deviation correction is carried out. The titration test results show that the combination of the segmented pipetting kinematic model of the double threshold method of pressure monitoring, can effectively real-time judgment and classification of the pipette fault. The method of closed-loop adjustment of pipetting volume can effectively improve the accuracy and reliability of the pipetting system.
Cao, Hengyi; Plichta, Michael M; Schäfer, Axel; Haddad, Leila; Grimm, Oliver; Schneider, Michael; Esslinger, Christine; Kirsch, Peter; Meyer-Lindenberg, Andreas; Tost, Heike
2014-01-01
The investigation of the brain connectome with functional magnetic resonance imaging (fMRI) and graph theory analyses has recently gained much popularity, but little is known about the robustness of these properties, in particular those derived from active fMRI tasks. Here, we studied the test-retest reliability of brain graphs calculated from 26 healthy participants with three established fMRI experiments (n-back working memory, emotional face-matching, resting state) and two parcellation schemes for node definition (AAL atlas, functional atlas proposed by Power et al.). We compared the intra-class correlation coefficients (ICCs) of five different data processing strategies and demonstrated a superior reliability of task-regression methods with condition-specific regressors. The between-task comparison revealed significantly higher ICCs for resting state relative to the active tasks, and a superiority of the n-back task relative to the face-matching task for global and local network properties. While the mean ICCs were typically lower for the active tasks, overall fair to good reliabilities were detected for global and local connectivity properties, and for the n-back task with both atlases, smallworldness. For all three tasks and atlases, low mean ICCs were seen for the local network properties. However, node-specific good reliabilities were detected for node degree in regions known to be critical for the challenged functions (resting-state: default-mode network nodes, n-back: fronto-parietal nodes, face-matching: limbic nodes). Between-atlas comparison demonstrated significantly higher reliabilities for the functional parcellations for global and local network properties. Our findings can inform the choice of processing strategies, brain atlases and outcome properties for fMRI studies using active tasks, graph theory methods, and within-subject designs, in particular future pharmaco-fMRI studies. © 2013 Elsevier Inc. All rights reserved.
Pinch aperture proprioception: reliability and feasibility study
Yahya, Abdalghani; von Behren, Timothy; Levine, Shira; dos Santos, Marcio
2018-01-01
[Purpose] To establish the reliability and feasibility of a novel pinch aperture device to measure proprioceptive joint position sense. [Subjects and Methods] Reliability of the pinch aperture device was assessed in 21 healthy subjects. Following familiarization with a 15° target position of the index finger and thumb, subjects performed 5 trials in which they attempted to actively reproduce the target position without visual feedback. This procedure was repeated at a testing session on a separate date, and the between-session intraclass correlation coefficient (ICC) was calculated. In addition, extensor tendon vibration was applied to 19 healthy subjects, and paired t-tests were conducted to compare performance under vibration and no-vibration conditions. Pinch aperture proprioception was also assessed in two individuals with known diabetic neuropathy. [Results] The pinch aperture device demonstrated excellent reliability in healthy subjects (ICC 0.88, 95% confidence interval 0.70–0.95). Tendon vibration disrupted pinch aperture proprioception, causing subjects to undershoot the target position (18.1 ± 2.6° vs. 14.8° ± 0.76, p<0.001). This tendency to undershoot the target position was also noted in individuals with diabetic neuropathy. [Conclusion] This study describes a reliable, feasible, and functional means of measuring finger proprioception. Further research should investigate the assessment and implications of pinch aperture proprioception in neurological and orthopedic populations. PMID:29765192
ERIC Educational Resources Information Center
van Iterson, Loretta; Augustijn, Paul B.; de Jong, Peter F.; van der Leij, Aryan
2013-01-01
The goal of this study was to investigate reliable cognitive change in epilepsy by developing computational procedures to determine reliable change index scores (RCIs) for the Dutch Wechsler Intelligence Scales for Children. First, RCIs were calculated based on stability coefficients from a reference sample. Then, these RCIs were applied to a…
Cognitive Decline in Down Syndrome: A Validity/Reliability Study of the Test for Severe Impairment.
ERIC Educational Resources Information Center
Cosgrave, Mary P.; McCarron, Mary; Anderson, Mary; Tyrrell, Janette; Gill, Michael; Lawlor, Brian A.
1998-01-01
The utility of the Test for Severe Impairment was studied with 60 older persons who had Down Syndrome. Construct validity, test-retest reliability, and interrater reliability were established for the full study group and for subgroups based on degree of mental retardation and dementia status. Some possible applications and limitations of the test…
Non-invasive body temperature measurement of wild chimpanzees using fecal temperature decline.
Jensen, Siv Aina; Mundry, Roger; Nunn, Charles L; Boesch, Christophe; Leendertz, Fabian H
2009-04-01
New methods are required to increase our understanding of pathologic processes in wild mammals. We developed a noninvasive field method to estimate the body temperature of wild living chimpanzees habituated to humans, based on statistically fitting temperature decline of feces after defecation. The method was established with the use of control measures of human rectal temperature and subsequent changes in fecal temperature over time. The method was then applied to temperature data collected from wild chimpanzee feces. In humans, we found good correspondence between the temperature estimated by the method and the actual rectal temperature that was measured (maximum deviation 0.22 C). The method was successfully applied and the average estimated temperature of the chimpanzees was 37.2 C. This simple-to-use field method reliably estimates the body temperature of wild chimpanzees and probably also other large mammals.
Simple method for quick estimation of aquifer hydrogeological parameters
NASA Astrophysics Data System (ADS)
Ma, C.; Li, Y. Y.
2017-08-01
Development of simple and accurate methods to determine the aquifer hydrogeological parameters was of importance for groundwater resources assessment and management. Aiming at the present issue of estimating aquifer parameters based on some data of the unsteady pumping test, a fitting function of Theis well function was proposed using fitting optimization method and then a unitary linear regression equation was established. The aquifer parameters could be obtained by solving coefficients of the regression equation. The application of the proposed method was illustrated, using two published data sets. By the error statistics and analysis on the pumping drawdown, it showed that the method proposed in this paper yielded quick and accurate estimates of the aquifer parameters. The proposed method could reliably identify the aquifer parameters from long distance observed drawdowns and early drawdowns. It was hoped that the proposed method in this paper would be helpful for practicing hydrogeologists and hydrologists.
Sajnóg, Adam; Hanć, Anetta; Barałkiewicz, Danuta
2018-05-15
Analysis of clinical specimens by imaging techniques allows to determine the content and distribution of trace elements on the surface of the examined sample. In order to obtain reliable results, the developed procedure should be based not only on the properly prepared sample and performed calibration. It is also necessary to carry out all phases of the procedure in accordance with the principles of chemical metrology whose main pillars are the use of validated analytical methods, establishing the traceability of the measurement results and the estimation of the uncertainty. This review paper discusses aspects related to sampling, preparation and analysis of clinical samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) with emphasis on metrological aspects, i.e. selected validation parameters of the analytical method, the traceability of the measurement result and the uncertainty of the result. This work promotes the introduction of metrology principles for chemical measurement with emphasis to the LA-ICP-MS which is the comparative method that requires studious approach to the development of the analytical procedure in order to acquire reliable quantitative results. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Song-Hua; Chang, James Y. H.; Boring,Ronald L.
2010-03-01
The Office of Nuclear Regulatory Research (RES) at the US Nuclear Regulatory Commission (USNRC) is sponsoring work in response to a Staff Requirements Memorandum (SRM) directing an effort to establish a single human reliability analysis (HRA) method for the agency or guidance for the use of multiple methods. As part of this effort an attempt to develop a comprehensive HRA qualitative approach is being pursued. This paper presents a draft of the method's middle layer, a part of the qualitative analysis phase that links failure mechanisms to performance shaping factors. Starting with a Crew Response Tree (CRT) that has identifiedmore » human failure events, analysts identify potential failure mechanisms using the mid-layer model. The mid-layer model presented in this paper traces the identification of the failure mechanisms using the Information-Diagnosis/Decision-Action (IDA) model and cognitive models from the psychological literature. Each failure mechanism is grouped according to a phase of IDA. Under each phase of IDA, the cognitive models help identify the relevant performance shaping factors for the failure mechanism. The use of IDA and cognitive models can be traced through fault trees, which provide a detailed complement to the CRT.« less
Colony-PCR Is a Rapid Method for DNA Amplification of Hyphomycetes
Walch, Georg; Knapp, Maria; Rainer, Georg; Peintner, Ursula
2016-01-01
Fungal pure cultures identified with both classical morphological methods and through barcoding sequences are a basic requirement for reliable reference sequences in public databases. Improved techniques for an accelerated DNA barcode reference library construction will result in considerably improved sequence databases covering a wider taxonomic range. Fast, cheap, and reliable methods for obtaining DNA sequences from fungal isolates are, therefore, a valuable tool for the scientific community. Direct colony PCR was already successfully established for yeasts, but has not been evaluated for a wide range of anamorphic soil fungi up to now, and a direct amplification protocol for hyphomycetes without tissue pre-treatment has not been published so far. Here, we present a colony PCR technique directly from fungal hyphae without previous DNA extraction or other prior manipulation. Seven hundred eighty-eight fungal strains from 48 genera were tested with a success rate of 86%. PCR success varied considerably: DNA of fungi belonging to the genera Cladosporium, Geomyces, Fusarium, and Mortierella could be amplified with high success. DNA of soil-borne yeasts was always successfully amplified. Absidia, Mucor, Trichoderma, and Penicillium isolates had noticeably lower PCR success. PMID:29376929
Plant, Katherine L; Stanton, Neville A
2013-01-01
Aeronautical decision-making is complex as there is not always a clear coupling between the decision made and decision outcome. As such, there is a call for process-orientated decision research in order to understand why a decision made sense at the time it was made. Schema theory explains how we interact with the world using stored mental representations and forms an integral part of the perceptual cycle model (PCM); proposed here as a way to understand the decision-making process. This paper qualitatively analyses data from the critical decision method (CDM) based on the principles of the PCM. It is demonstrated that the approach can be used to understand a decision-making process and highlights how influential schemata can be at informing decision-making. The reliability of this approach is established, the general applicability is discussed and directions for future work are considered. This paper introduces the PCM, and the associated schema theory, as a framework to structure and explain data collected from the CDM. The reliability of both the method and coding scheme is addressed.
Farouk, Abd-ElAziem; Batcha, Mohamed F; Greiner, Ralf; Salleh, Hamzah M; Salleh, Mohamad R; Sirajudin, Abdur R
2006-09-01
To develop a molecular technique that is fast and reliable in detecting porcine contamination or ingredients in foods. The method applied involved DNA amplification using polymerase chain reaction (PCR) technology. Thus, the sequence of a certain gene found uniquely in pork was identified and its sequence was used to design specific primers for the PCR. The extraction of DNA was optimized in respect to PCR and detection limits were established. The optimized method was then used to identify pork in food products obtained from various local hypermarkets. The latest results were confirmed in triplicates on the 20th April 2006 at the Molecular Biology Laboratory, International Islamic University, Malaysia. The method was shown to be robust and reliable. Out of 30 food samples not expected to contain pork material, 3 samples were shown to be contaminated with pork material; 2 chocolates and one chicken nugget. We observed that 2 food products that were labeled as halal showed positive for porcine ingredients, while another that did not have any halal logo but originated from outside Malaysia and exported to many Middle Eastern nations also showed positive.
Analysis of the iteratively regularized Gauss-Newton method under a heuristic rule
NASA Astrophysics Data System (ADS)
Jin, Qinian; Wang, Wei
2018-03-01
The iteratively regularized Gauss-Newton method is one of the most prominent regularization methods for solving nonlinear ill-posed inverse problems when the data is corrupted by noise. In order to produce a useful approximate solution, this iterative method should be terminated properly. The existing a priori and a posteriori stopping rules require accurate information on the noise level, which may not be available or reliable in practical applications. In this paper we propose a heuristic selection rule for this regularization method, which requires no information on the noise level. By imposing certain conditions on the noise, we derive a posteriori error estimates on the approximate solutions under various source conditions. Furthermore, we establish a convergence result without using any source condition. Numerical results are presented to illustrate the performance of our heuristic selection rule.
Yan, Zhou; Xia, Bing; Qiu, Ming Hua; Li Sheng, Ding; Xu, Hong Xi
2013-11-01
A rapid and reliable method was established for simultaneous determination of main triterpenoids in Ganoderma lucidum spores using ultra-high-performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC-TQ-MS). The established method was validated in terms of linearity, sensitivity, precision, accuracy and stability, and was successfully applied to determine the contents of 10 main triterpenoids in different batches of G. lucidum spores. The analysis results showed that moderate levels of triterpenoids were found in G. lucidum spores. In addition, a MS full scan with a daughter ion scan experiment was performed to identify the potential derivatives of triterpenoids present in G. lucidum spores. As a result, a total of 22 triterpenoids from different G. lucidum spores were unequivocally or tentatively identified via comparisons with authentic standards and literatures. This method provides both qualitative and quantitative results without the need for repetitive UPLC-MS analyses, thereby increasing efficiency and productivity, making it suitable for high-throughput applications. Copyright © 2013 John Wiley & Sons, Ltd.
Improved Virtual Planning for Bimaxillary Orthognathic Surgery.
Hatamleh, Muhanad; Turner, Catherine; Bhamrah, Gurprit; Mack, Gavin; Osher, Jonas
2016-09-01
Conventional model surgery planning for bimaxillary orthognathic surgery can be laborious, time-consuming and may contain potential errors; hence three-dimensional (3D) virtual orthognathic planning has been proven to be an efficient, reliable, and cost-effective alternative. In this report, the 3D planning is described for a patient presenting with a Class III incisor relationship on a Skeletal III base with pan facial asymmetry complicated by reverse overjet and anterior open bite. A combined scan data of direct cone beam computer tomography and indirect dental scan were used in the planning. Additionally, a new method of establishing optimum intercuspation by scanning dental casts in final occlusion and positioning it to the composite-scans model was shown. Furthermore, conventional model surgery planning was carried out following in-house protocol. Intermediate and final intermaxillary splints were produced following the conventional method and 3D printing. Three-dimensional planning showed great accuracy and treatment outcome and reduced laboratory time in comparison with the conventional method. Establishing the final dental occlusion on casts and integrating it in final 3D planning enabled us to achieve the best possible intercuspation.
Validation of the Australian Propensity for Angry Driving Scale (Aus-PADS).
Leal, Nerida L; Pachana, Nancy A
2009-09-01
The present study used a university sample to assess the test-retest reliability and validity of the Australian Propensity for Angry Driving Scale (Aus-PADS). The scale has stability over time, and convergent validity was established, as Aus-PADS scores correlated significantly with established anger and impulsivity measures. Discriminant validity was also established, as Aus-PADS scores did not correlate with Venturesomeness scores. The Aus-PADS has demonstrated criterion validity, as scores were correlated with behavioural measures, such as yelling at other drivers, gesturing at other drivers, and feeling angry but not doing anything. Aus-PADS scores reliably predicted the frequency of these behaviours over and above other study variables. No significant relationship between aggressive driving and crash involvement was observed. It was concluded that the Aus-PADS is a reliable and valid tool appropriate for use in Australian research, and that the potential relationship between aggressive driving and crash involvement warrants further investigation with a more representative (and diverse) driver sample.
Ghaderi, Forouzan; Ghaderi, Amir H; Ghaderi, Noushin; Najafi, Bijan
2017-01-01
Background: The thermal conductivity of fluids can be calculated by several computational methods. However, these methods are reliable only at the confined levels of density, and there is no specific computational method for calculating thermal conductivity in the wide ranges of density. Methods: In this paper, two methods, an Artificial Neural Network (ANN) approach and a computational method established upon the Rainwater-Friend theory, were used to predict the value of thermal conductivity in all ranges of density. The thermal conductivity of six refrigerants, R12, R14, R32, R115, R143, and R152 was predicted by these methods and the effectiveness of models was specified and compared. Results: The results show that the computational method is a usable method for predicting thermal conductivity at low levels of density. However, the efficiency of this model is considerably reduced in the mid-range of density. It means that this model cannot be used at density levels which are higher than 6. On the other hand, the ANN approach is a reliable method for thermal conductivity prediction in all ranges of density. The best accuracy of ANN is achieved when the number of units is increased in the hidden layer. Conclusion: The results of the computational method indicate that the regular dependence between thermal conductivity and density at higher densities is eliminated. It can develop a nonlinear problem. Therefore, analytical approaches are not able to predict thermal conductivity in wide ranges of density. Instead, a nonlinear approach such as, ANN is a valuable method for this purpose.
Ghaderi, Forouzan; Ghaderi, Amir H.; Ghaderi, Noushin; Najafi, Bijan
2017-01-01
Background: The thermal conductivity of fluids can be calculated by several computational methods. However, these methods are reliable only at the confined levels of density, and there is no specific computational method for calculating thermal conductivity in the wide ranges of density. Methods: In this paper, two methods, an Artificial Neural Network (ANN) approach and a computational method established upon the Rainwater-Friend theory, were used to predict the value of thermal conductivity in all ranges of density. The thermal conductivity of six refrigerants, R12, R14, R32, R115, R143, and R152 was predicted by these methods and the effectiveness of models was specified and compared. Results: The results show that the computational method is a usable method for predicting thermal conductivity at low levels of density. However, the efficiency of this model is considerably reduced in the mid-range of density. It means that this model cannot be used at density levels which are higher than 6. On the other hand, the ANN approach is a reliable method for thermal conductivity prediction in all ranges of density. The best accuracy of ANN is achieved when the number of units is increased in the hidden layer. Conclusion: The results of the computational method indicate that the regular dependence between thermal conductivity and density at higher densities is eliminated. It can develop a nonlinear problem. Therefore, analytical approaches are not able to predict thermal conductivity in wide ranges of density. Instead, a nonlinear approach such as, ANN is a valuable method for this purpose. PMID:29188217
Obtaining reliable phase-gradient delays from otoacoustic emission data.
Shera, Christopher A; Bergevin, Christopher
2012-08-01
Reflection-source otoacoustic emission phase-gradient delays are widely used to obtain noninvasive estimates of cochlear function and properties, such as the sharpness of mechanical tuning and its variation along the length of the cochlear partition. Although different data-processing strategies are known to yield different delay estimates and trends, their relative reliability has not been established. This paper uses in silico experiments to evaluate six methods for extracting delay trends from reflection-source otoacoustic emissions (OAEs). The six methods include both previously published procedures (e.g., phase smoothing, energy-weighting, data exclusion based on signal-to-noise ratio) and novel strategies (e.g., peak-picking, all-pass factorization). Although some of the methods perform well (e.g., peak-picking), others introduce substantial bias (e.g., phase smoothing) and are not recommended. In addition, since standing waves caused by multiple internal reflection can complicate the interpretation and compromise the application of OAE delays, this paper develops and evaluates two promising signal-processing strategies, the first based on time-frequency filtering using the continuous wavelet transform and the second on cepstral analysis, for separating the direct emission from its subsequent reflections. Altogether, the results help to resolve previous disagreements about the frequency dependence of human OAE delays and the sharpness of cochlear tuning while providing useful analysis methods for future studies.
Data driven CAN node reliability assessment for manufacturing system
NASA Astrophysics Data System (ADS)
Zhang, Leiming; Yuan, Yong; Lei, Yong
2017-01-01
The reliability of the Controller Area Network(CAN) is critical to the performance and safety of the system. However, direct bus-off time assessment tools are lacking in practice due to inaccessibility of the node information and the complexity of the node interactions upon errors. In order to measure the mean time to bus-off(MTTB) of all the nodes, a novel data driven node bus-off time assessment method for CAN network is proposed by directly using network error information. First, the corresponding network error event sequence for each node is constructed using multiple-layer network error information. Then, the generalized zero inflated Poisson process(GZIP) model is established for each node based on the error event sequence. Finally, the stochastic model is constructed to predict the MTTB of the node. The accelerated case studies with different error injection rates are conducted on a laboratory network to demonstrate the proposed method, where the network errors are generated by a computer controlled error injection system. Experiment results show that the MTTB of nodes predicted by the proposed method agree well with observations in the case studies. The proposed data driven node time to bus-off assessment method for CAN networks can successfully predict the MTTB of nodes by directly using network error event data.