Zhao, Dan; Azimi, Parham; Stephens, Brent
2015-01-01
Much of human exposure to fine particulate matter (PM2.5) of outdoor origin occurs in residences. High-efficiency particle air filtration in central heating, ventilating, and air-conditioning (HVAC) systems is increasingly being used to reduce concentrations of particulate matter inside homes. However, questions remain about the effectiveness of filtration for reducing exposures to PM2.5 of outdoor origin and adverse health outcomes. Here we integrate epidemiology functions and mass balance modeling to estimate the long-term health and economic impacts of HVAC filtration for reducing premature mortality associated with indoor PM2.5 of outdoor origin in residences. We evaluate 11 classifications of filters (MERV 5 through HEPA) using six case studies of single-family home vintages and ventilation system combinations located in 22 U.S. cities. We estimate that widespread use of higher efficiency filters would reduce premature mortality by 0.002–2.5% and increase life expectancy by 0.02–1.6 months, yielding annual monetary benefits ranging from $1 to $1348 per person in the homes and locations modeled herein. Large differences in the magnitude of health and economic impacts are driven largely by differences in rated filter efficiency and building and ventilation system characteristics that govern particle infiltration and persistence, with smaller influences attributable to geographic location. PMID:26197328
Zhao, Dan; Azimi, Parham; Stephens, Brent
2015-07-21
Much of human exposure to fine particulate matter (PM2.5) of outdoor origin occurs in residences. High-efficiency particle air filtration in central heating, ventilating, and air-conditioning (HVAC) systems is increasingly being used to reduce concentrations of particulate matter inside homes. However, questions remain about the effectiveness of filtration for reducing exposures to PM2.5 of outdoor origin and adverse health outcomes. Here we integrate epidemiology functions and mass balance modeling to estimate the long-term health and economic impacts of HVAC filtration for reducing premature mortality associated with indoor PM2.5 of outdoor origin in residences. We evaluate 11 classifications of filters (MERV 5 through HEPA) using six case studies of single-family home vintages and ventilation system combinations located in 22 U.S. cities. We estimate that widespread use of higher efficiency filters would reduce premature mortality by 0.002-2.5% and increase life expectancy by 0.02-1.6 months, yielding annual monetary benefits ranging from $1 to $1348 per person in the homes and locations modeled herein. Large differences in the magnitude of health and economic impacts are driven largely by differences in rated filter efficiency and building and ventilation system characteristics that govern particle infiltration and persistence, with smaller influences attributable to geographic location.
Singer, B C; Delp, W W; Black, D R; Walker, I S
2017-07-01
This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250 m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration provided indoor PM 2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection, whereas supply MERV16 filtration reduced PM 2.5 by 97-98% relative to outdoors. Supply filtration systems used little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 filter in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM 2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM 2.5 . Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM 2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, Brett C.; Delp, William W.; Black, Douglas R.
This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration produced indoor PM 2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection whereas supply MERV16 filtration reduced PM 2.55 by 97-98% relative to outdoors. Supply filtration systems usedmore » little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 filters in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM 2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM 2.5. Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM 2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, B. C.; Delp, W. W.; Black, D. R.
This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250 m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration provided indoor PM 2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection, whereas supply MERV16 filtration reduced PM 2.5 by 97-98% relative to outdoors. Supply filtration systems usedmore » little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 fil ter in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM 2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM 2.5 . Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM 2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.« less
Singer, B. C.; Delp, W. W.; Black, D. R.; ...
2016-12-05
This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250 m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration provided indoor PM 2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection, whereas supply MERV16 filtration reduced PM 2.5 by 97-98% relative to outdoors. Supply filtration systems usedmore » little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 fil ter in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM 2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM 2.5 . Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM 2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.« less
Enhanced performance of crumb rubber filtration for ballast water treatment.
Tang, Zhijian; Butkus, Michael A; Xie, Yuefeng F
2009-03-01
Waste-tire-derived crumb rubber was utilized as filter media to develop an efficient filter for ballast water treatment. In this study, the effects of coagulation, pressure filtration and dual-media (gravity) filtration on the performance of the crumb rubber filtration were investigated. The removal efficiencies of turbidity, phytoplankton and zooplankton, and head loss development were monitored during the filtration process. The addition of a coagulant enhanced the removal efficiencies of all targeted matter, but resulted in substantial increase of head loss. Pressure filtration increased filtration rates to 220 m(3)h(-1)m(-2) for 8-h operation and improved the zooplankton removal. Dual-media (crumb rubber/sand) gravity filtration also improved the removal efficiencies of phytoplankton and zooplankton over mono-media gravity crumb rubber filtration. However, these filtration techniques alone did not meet the criteria for removing indigenous organisms from ballast water. A combination of filtration and disinfection is suggested for future studies.
NASA Astrophysics Data System (ADS)
Shuler, Harrey Jeong
Information technology (IT) is becoming increasingly pervasive throughout society as more data is digitally processed, stored, and transferred. The infrastructure that supports IT activity is growing accordingly, and data center energy demands have increased by nearly a factor of four over the past decade. This dissertation investigates how building design and operation influence energy use and indoor air quality in data centers and provides strategies to improve both design goals simultaneously. As an initial step toward understanding data center air quality, measurements of particle concentrations were made at multiple operating northern California data centers. Ratios of measured particle concentrations in conventional data centers to the corresponding outside concentrations were significantly lower than those reported in the literature for office or residential buildings. Estimates using a material-balance model match well with empirical results, indicating that the dominant particle sources and losses---ventilation and filtration---have been characterized. Measurements taken at a data center using economizers show nearly an order of magnitude increase in particle concentration during economizer activity. However, even with the increase, the measured particle concentrations are still below concentration limits recommended in most industry standards. The research proceeds by exploring the feasibility of using economizers in data centers while simultaneously controlling particle concentrations with high-quality air filtration. Physical and chemical properties of indoor and outdoor particles were analyzed at a data center using economizers and varying levels of air filtration efficiency. Results show that when improved filtration is used in combination with an economizer, the indoor/outdoor concentration ratios for most measured particle types were similar to the measurements when using conventional filtration without economizers. An energy analysis of the data center reveals that, even during the summer months, chiller savings from economizer use greatly outweigh the increase in fan power associated with improved filtration. These findings indicate that economizer use combined with improved filtration could significantly reduce data center energy demand while providing a level of protection from particles of outdoor origin similar to that observed with conventional design. The emphasis of the dissertation then shifts to evaluate the energy benefits of economizer use in data centers under different design strategies. Economizer use with high ventilation rates is compared against an alternative, water-side economizer design that does not affect indoor particle concentrations. Building energy models are employed to estimate energy savings of both economizer designs for data centers in several climate zones in California. Results show that water-side economizers consistently provide less energy savings than air-side economizers, though the difference in savings varies by location. Model results also show that conventional limits on humidity levels in data centers can restrict the energy benefits of economizers. The modeling efforts are then extended to estimate national data center energy use. Different size data centers are modeled to represent the national variation in efficiency and operation of associated mechanical equipment. Results indicate increased energy efficiency opportunities with larger data centers and highlight the importance of temperature setpoints in maximizing economizer efficiency. A bottom-up modeling approach is used to estimate current (2008) United States data center energy use at nearly 62--70 billion kWh annually. The model indicates that more about 65--70% of this energy demand can be avoided through energy efficient IT and cooling infrastructure design, equivalent to an annual energy efficiency resource of approximately 40--50 billion kWh available at a national level. Within the context of greenhouse gas emissions, benefits can be significantly increased by incorporating site location into energy-efficient design strategies. (Abstract shortened by UMI.).
Chan, W R; Parthasarathy, S; Fisk, W J; McKone, T E
2016-04-01
We assessed the chronic health risks from inhalation exposure to volatile organic compounds (VOCs) and particulate matter (PM2.5) in U.S. offices, schools, grocery, and other retail stores and evaluated how chronic health risks were affected by changes in ventilation rates and air filtration efficiency. Representative concentrations of VOCs and PM2.5 were obtained from available data. Using a mass balance model, changes in exposure to VOCs and PM2.5 were predicted if ventilation rate were to increase or decrease by a factor of two, and if higher efficiency air filters were used. Indoor concentrations were compared to health guidelines to estimate percentage exceedances. The estimated chronic health risks associated with VOC and PM2.5 exposures in these buildings were low relative to the risks from exposures in homes. Chronic health risks were driven primarily by exposures to PM2.5 that were evaluated using disease incidence of mortality, chronic bronchitis, and non-fatal stroke. The leading cancer risk factor was exposure to formaldehyde. Using disability-adjusted life years (DALYs) to account for both cancer and non-cancer effects, results suggest that increasing ventilation alone is ineffective at reducing chronic health burdens. Other strategies, such as pollutant source control and the use of particle filtration, should also be considered. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Pang, Liping; Close, Murray; Goltz, Mark; Noonan, Mike; Sinton, Lester
2005-04-01
Filtration of Bacillus subtilis spores and the F-RNA phage MS2 (MS2) on a field scale in a coarse alluvial gravel aquifer was evaluated from the authors' previously published data. An advection-dispersion model that is coupled with first-order attachment kinetics was used in this study to interpret microbial concentration vs. time breakthrough curves (BTC) at sampling wells. Based on attachment rates (katt) that were determined by applying the model to the breakthrough data, filter factors (f) were calculated and compared with f values estimated from the slopes of log (cmax/co) vs. distance plots. These two independent approaches resulted in nearly identical filter factors, suggesting that both approaches are useful in determining reductions in microbial concentrations over transport distance. Applying the graphic approach to analyse spatial data, we have also estimated the f values for different aquifers using information provided by some other published field studies. The results show that values of f, in units of log (cmax/co) m(-1), are consistently in the order of 10(-2) for clean coarse gravel aquifers, 10(-3) for contaminated coarse gravel aquifers, and generally 10(-1) for sandy fine gravel aquifers and river and coastal sand aquifers. For each aquifer category, the f values for bacteriophages and bacteria are in the same order-of-magnitude. The f values estimated in this study indicate that for every one-log reduction in microbial concentration in groundwater, it requires a few tens of meters of travel in clean coarse gravel aquifers, but a few hundreds of meters in contaminated coarse gravel aquifers. In contrast, a one-log reduction generally only requires a few meters of travel in sandy fine gravel aquifers and sand aquifers. Considering the highest concentration in human effluent is in the order of 10(4) pfu/l for enteroviruses and 10(6) cfu/100 ml for faecal coliform bacteria, a 7-log reduction in microbial concentration would comply with the drinking water standards for the downgradient wells under natural gradient conditions. Based on the results of this study, a 7-log reduction would require 125-280 m travel in clean coarse gravel aquifers, 1.7-3.9 km travel in contaminated coarse gravel aquifers, 33-61 m travel in clean sandy fine gravel aquifers, 33-129 m travel in contaminated sandy fine gravel aquifers, and 37-44 m travel in contaminated river and coastal sand aquifers. These recommended setback distances are for a worst-case scenario, assuming direct discharge of raw effluent into the saturated zone of an aquifer. Filtration theory was applied to calculate collision efficiency (alpha) from model-derived attachment rates (katt), and the results are compared with those reported in the literature. The calculated alpha values vary by two orders-of-magnitude, depending on whether collision efficiency is estimated from the effective particle size (d10) or the mean particle size (d50). Collision efficiency values for MS-2 are similar to those previously reported in the literature (e.g. ) [DeBorde, D.C., Woessner, W.W., Kiley, QT., Ball, P., 1999. Rapid transport of viruses in a floodplain aquifer. Water Res. 33 (10), 2229-2238]. However, the collision efficiency values calculated for Bacillus subtilis spores were unrealistic, suggesting that filtration theory is not appropriate for theoretically estimating filtration capacity for poorly sorted coarse gravel aquifer media. This is not surprising, as filtration theory was developed for uniform sand filters and does not consider particle size distribution. Thus, we do not recommend the use of filtration theory to estimate the filter factor or setback distances. Either of the methods applied in this work (BTC or concentration vs. distance analyses), which takes into account aquifer heterogeneities and site-specific conditions, appear to be most useful in determining filter factors and setback distances.
NASA Astrophysics Data System (ADS)
Pang, Liping; Close, Murray; Goltz, Mark; Noonan, Mike; Sinton, Lester
2005-04-01
Filtration of Bacillus subtilis spores and the F-RNA phage MS2 (MS2) on a field scale in a coarse alluvial gravel aquifer was evaluated from the authors' previously published data. An advection-dispersion model that is coupled with first-order attachment kinetics was used in this study to interpret microbial concentration vs. time breakthrough curves (BTC) at sampling wells. Based on attachment rates ( katt) that were determined by applying the model to the breakthrough data, filter factors ( f) were calculated and compared with f values estimated from the slopes of log ( cmax/ co) vs. distance plots. These two independent approaches resulted in nearly identical filter factors, suggesting that both approaches are useful in determining reductions in microbial concentrations over transport distance. Applying the graphic approach to analyse spatial data, we have also estimated the f values for different aquifers using information provided by some other published field studies. The results show that values of f, in units of log ( cmax/ co) m -1, are consistently in the order of 10 -2 for clean coarse gravel aquifers, 10 -3 for contaminated coarse gravel aquifers, and generally 10 -1 for sandy fine gravel aquifers and river and coastal sand aquifers. For each aquifer category, the f values for bacteriophages and bacteria are in the same order-of-magnitude. The f values estimated in this study indicate that for every one-log reduction in microbial concentration in groundwater, it requires a few tens of meters of travel in clean coarse gravel aquifers, but a few hundreds of meters in contaminated coarse gravel aquifers. In contrast, a one-log reduction generally only requires a few meters of travel in sandy fine gravel aquifers and sand aquifers. Considering the highest concentration in human effluent is in the order of 10 4 pfu/l for enteroviruses and 10 6 cfu/100 ml for faecal coliform bacteria, a 7-log reduction in microbial concentration would comply with the drinking water standards for the downgradient wells under natural gradient conditions. Based on the results of this study, a 7-log reduction would require 125-280 m travel in clean coarse gravel aquifers, 1.7-3.9 km travel in contaminated coarse gravel aquifers, 33-61 m travel in clean sandy fine gravel aquifers, 33-129 m travel in contaminated sandy fine gravel aquifers, and 37-44 m travel in contaminated river and coastal sand aquifers. These recommended setback distances are for a worst-case scenario, assuming direct discharge of raw effluent into the saturated zone of an aquifer. Filtration theory was applied to calculate collision efficiency ( α) from model-derived attachment rates ( katt), and the results are compared with those reported in the literature. The calculated α values vary by two orders-of-magnitude, depending on whether collision efficiency is estimated from the effective particle size ( d10) or the mean particle size ( d50). Collision efficiency values for MS-2 are similar to those previously reported in the literature (e.g. DeBorde et al., 1999) [DeBorde, D.C., Woessner, W.W., Kiley, QT., Ball, P., 1999. Rapid transport of viruses in a floodplain aquifer. Water Res. 33 (10), 2229-2238]. However, the collision efficiency values calculated for Bacillus subtilis spores were unrealistic, suggesting that filtration theory is not appropriate for theoretically estimating filtration capacity for poorly sorted coarse gravel aquifer media. This is not surprising, as filtration theory was developed for uniform sand filters and does not consider particle size distribution. Thus, we do not recommend the use of filtration theory to estimate the filter factor or setback distances. Either of the methods applied in this work (BTC or concentration vs. distance analyses), which takes into account aquifer heterogeneities and site-specific conditions, appear to be most useful in determining filter factors and setback distances.
Fluorometric Method for Determining the Efficiency of Spun-Glass Air Filtration Media
Sullivan, James F.; Songer, Joseph R.; Mathis, Raymond G.
1967-01-01
The procedures and equipment needed to measure filtration efficiency by means of fluorescent aerosols are described. The filtration efficiency of individual lots of spun-glass air filtration medium or of entire air filtration systems employing such media was determined. Data relating to the comparative evaluation of spun-glass filter media by means of the fluorometric method described, as well as by conventional biological procedures, are presented. PMID:6031433
Experimental investigation of air pressure affecting filtration performance of fibrous filter sheet.
Xu, Bin; Yu, Xiao; Wu, Ya; Lin, Zhongping
2017-03-01
Understanding the effect of air pressure on their filtration performance is important for assessing the effectiveness of fibrous filters under different practical circumstances. The effectiveness of three classes of air filter sheets were investigated in laboratory-based measurements at a wide range of air pressures (60-130 KPa). The filtration efficiency was found most sensitive to the air pressure change at smaller particle sizes. As the air pressure increased from 60 to 130 KPa, significant decrease in filtration efficiency (up to 15%) and increase in pressure drop (up to 90 Pa) were observed. The filtration efficiency of the filter sheet with largest fiber diameter and smallest solid volume fraction was affected most, while the pressure drop of the filter sheet with smallest fiber diameter and largest solid volume fraction was affected most. The effect of air pressure on the filtration efficiency was slightly larger at greater filter face air velocity. However, the effect of air pressure on the pressure drop was negligible. The filtration efficiency and pressure drop were explicitly expressed as functions of the air pressure. Two coefficients were empirically derived and successfully accounted for the effects of air pressure on filtration efficiency and pressure drop.
Crumb rubber filtration: a potential technology for ballast water treatment.
Tang, Zhijian; Butkus, Michael A; Xie, Yuefeng F
2006-05-01
The removal of turbidity, particles, phytoplankton and zooplankton in water by crumb rubber filtration was investigated. A substantial reduction was achieved. Of the three variables, filter depth, media size and filtration rate, media size had the most significant influence. Smaller media size favored higher removal efficiency of all targeted matter. There was no apparent relationship between removal efficiency and filter depth. Higher filtration rate resulted in lower removal efficiency and higher head loss. Compared with conventional granular media filters, crumb rubber filters required less backwash, and developed lower head loss. Consequently crumb rubber filters could be run for a longer time or allow a higher filtration rate. The results also indicate that the crumb rubber filtration alone did not achieve the target removal of invasive species. However, crumb rubber filtration could potentially be used as a primary treatment technology to enhance the efficiency of a secondary treatment process (e.g., disinfection).
Dong, Jianghu J; Wang, Liangliang; Gill, Jagbir; Cao, Jiguo
2017-01-01
This article is motivated by some longitudinal clinical data of kidney transplant recipients, where kidney function progression is recorded as the estimated glomerular filtration rates at multiple time points post kidney transplantation. We propose to use the functional principal component analysis method to explore the major source of variations of glomerular filtration rate curves. We find that the estimated functional principal component scores can be used to cluster glomerular filtration rate curves. Ordering functional principal component scores can detect abnormal glomerular filtration rate curves. Finally, functional principal component analysis can effectively estimate missing glomerular filtration rate values and predict future glomerular filtration rate values.
Expanded uncertainty estimation methodology in determining the sandy soils filtration coefficient
NASA Astrophysics Data System (ADS)
Rusanova, A. D.; Malaja, L. D.; Ivanov, R. N.; Gruzin, A. V.; Shalaj, V. V.
2018-04-01
The combined standard uncertainty estimation methodology in determining the sandy soils filtration coefficient has been developed. The laboratory researches were carried out which resulted in filtration coefficient determination and combined uncertainty estimation obtaining.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viswanathan, Sandeep; Rothamer, David; Zelenyuk, Alla
The impact of inlet particle properties on the filtration performance of clean and particulate matter (PM) laden cordierite filter samples was evaluated using PM generated by a spark-ignition direct-injection (SIDI) engine fuelled with tier II EEE certification gasoline. Prior to the filtration experiments, a scanning mobility particle spectrometer (SMPS) was used to measure the electrical-mobility based particle size distribution (PSD) in the SIDI exhaust from distinct engine operating conditions. An advanced aerosol characterization system that comprised of a centrifugal particle mass analyser (CPMA), a differential mobility analyser (DMA), and a single particle mass spectrometer (SPLAT II) was used to obtainmore » additional information on the SIDI particulate, including particle composition, mass, and dynamic shape factors (DSFs) in the transition () and free-molecular () flow regimes. During the filtration experiments, real-time measurements of PSDs upstream and downstream of the filter sample were used to estimate the filtration performance and the total trapped mass within the filter using an integrated particle size distribution method. The filter loading process was paused multiple times to evaluate the filtration performance in the partially loaded state. The change in vacuum aerodynamic diameter () distribution of mass-selected particles was examined for flow through the filter to identify whether preferential capture of particles of certain shapes occurred in the filter. The filter was also probed using different inlet PSDs to understand their impact on particle capture within the filter sample. Results from the filtration experiment suggest that pausing the filter loading process and subsequently performing the filter probing experiments did not impact the overall evolution of filtration performance. Within the present distribution of particle sizes, filter efficiency was independent of particle shape potentially due to the diffusion-dominant filtration process. Particle mobility diameter and trapped mass within the filter appeared to be the dominant parameters that impacted filter performance.« less
Filtration Efficiency of Functionalized Ceramic Foam Filters for Aluminum Melt Filtration
NASA Astrophysics Data System (ADS)
Voigt, Claudia; Jäckel, Eva; Taina, Fabio; Zienert, Tilo; Salomon, Anton; Wolf, Gotthard; Aneziris, Christos G.; Le Brun, Pierre
2017-02-01
The influence of filter surface chemistry on the filtration efficiency of cast aluminum alloys was evaluated for four different filter coating compositions (Al2O3—alumina, MgAl2O4—spinel, 3Al2O3·2SiO2—mullite, and TiO2—rutile). The tests were conducted on a laboratory scale with a filtration pilot plant, which facilitates long-term filtration tests (40 to 76 minutes). This test set-up allows the simultaneous use of two LiMCAs (before and after the filter) for the determination of the efficiency of inclusion removal. The four tested filter surface chemistries exhibited good thermal stability and mechanical robustness after 750 kg of molten aluminum had been cast. All four filter types exhibited a mean filtration efficiency of at least 80 pct. However, differences were also observed. The highest filtration efficiencies were obtained with alumina- and spinel-coated filter surfaces (>90 pct), and the complete removal of the largest inclusions (>90 µm) was observed. The efficiency was slightly lower with mullite- and rutile-coated filter surfaces, in particular for large inclusions. These observations are discussed in relation to the properties of the filters, in particular in terms of, for example, the surface roughness.
Different methods of hilar clamping during partial nephrectomy: Impact on renal function.
Lee, Jeong Woo; Kim, Hwanik; Choo, Minsoo; Park, Yong Hyun; Ku, Ja Hyeon; Kim, Hyeon Hoe; Kwak, Cheol
2014-03-01
To evaluate the impact of different hilar clamping methods on changes in renal function after partial nephrectomy. We analyzed the clinical data of 369 patients who underwent partial nephrectomy for a single renal tumor of size ≤4.0 cm and a normal contralateral kidney. Patients were separated into three groups depending on hilar clamping method: non-clamping, cold ischemia and warm ischemia. Estimated glomerular filtration rate was examined at preoperative, nadir and 1 year postoperatively. Percent change in estimated glomerular filtration rate was used as the parameter to assess the renal functional outcome. Percent change in nadir estimated glomerular filtration rate in the non-clamping group was significantly less compared with the cold ischemia and warm ischemia groups (P < 0.001). However, no significant differences among the groups were noted in percent change of estimated glomerular filtration rate at 1 year (P = 0.348). The cold ischemia group had a similar serial change of postoperative renal function compared with the warm ischemia group. Percent change in 1-year estimated glomerular filtration rate increased with increasing ischemia time in the cold ischemia (P for trend = 0.073) and warm ischemia groups (P for trend = 0.010). On multivariate analysis, hilar clamping (both warm ischemia and cold ischemia) were significantly associated with percent change in nadir estimated glomerular filtration rate, but not in 1-year estimated glomerular filtration rate. Non-clamping partial nephrectomy results in a lower percent change in nadir estimated glomerular filtration rate, whereas it carries an estimated glomerular filtration rate change at 1 year that is similar to partial nephrectomy with cold ischemia and warm ischemia. Cold ischemia and warm ischemia provide a similar effect on renal function. Therefore, when hilar clamping is required, minimization of ischemia time is necessary. © 2013 The Japanese Urological Association.
Sim, Kyoung Mi; Park, Hyun-Seol; Bae, Gwi-Nam; Jung, Jae Hee
2015-11-15
In this study, we demonstrated an antimicrobial nanoparticle-coated electrostatic (ES) air filter. Antimicrobial natural-product Sophora flavescens nanoparticles were produced using an aerosol process, and were continuously deposited onto the surface of air filter media. For the electrostatic activation of the filter medium, a corona discharge electrification system was used before and after antimicrobial treatment of the filter. In the antimicrobial treatment process, the deposition efficiency of S. flavescens nanoparticles on the ES filter was ~12% higher than that on the pristine (Non-ES) filter. In the evaluation of filtration performance using test particles (a nanosized KCl aerosol and submicron-sized Staphylococcus epidermidis bioaerosol), the ES filter showed better filtration efficiency than the Non-ES filter. However, antimicrobial treatment with S. flavescens nanoparticles affected the filtration efficiency of the filter differently depending on the size of the test particles. While the filtration efficiency of the KCl nanoparticles was reduced on the ES filter after the antimicrobial treatment, the filtration efficiency was improved after the recharging process. In summary, we prepared an antimicrobial ES air filter with >99% antimicrobial activity, ~92.5% filtration efficiency (for a 300-nm KCl aerosol), and a ~0.8 mmAq pressure drop (at 13 cm/s). This study provides valuable information for the development of a hybrid air purification system that can serve various functions and be used in an indoor environment. Copyright © 2015 Elsevier B.V. All rights reserved.
Harvey, R.W.; Garabedian, S.P.
1991-01-01
??? A filtration model commonly used to describe removal of colloids during packed-bed filtration in water treatment applications was modified for describing downgradient transport of bacteria in sandy, aquifer sediments. The modified model was applied to the results of a small-scale (7 m), natural-gradient tracer test and to observations of an indigenous bacterial population moving downgradient within a plume of organically contaminated groundwater in Cape Cod, MA. The model reasonably accounted for concentration histories of labeled bacteria appearing at samplers downgradient from the injection well in the tracer experiment and for the observed 0.25-??m increase in average cell length for an unlabeled, indigenous bacterial population, 0.6 km downgradient from the source of the plume. Several uncertainties were apparent in applying filtration theory to problems involving transport of bacteria in groundwater. However, adsorption (attachment) appeared to be a major control of the extent of bacterial movement downgradient, which could be described, in part, by filtration theory. Estimates of the collision efficiency factor, which represents the physicochemical factors that determine adsorption of the bacteria onto the grain surfaces, ranged from 5.4 ?? 10-3 to 9.7 ?? 10-3.
PDF-based heterogeneous multiscale filtration model.
Gong, Jian; Rutland, Christopher J
2015-04-21
Motivated by modeling of gasoline particulate filters (GPFs), a probability density function (PDF) based heterogeneous multiscale filtration (HMF) model is developed to calculate filtration efficiency of clean particulate filters. A new methodology based on statistical theory and classic filtration theory is developed in the HMF model. Based on the analysis of experimental porosimetry data, a pore size probability density function is introduced to represent heterogeneity and multiscale characteristics of the porous wall. The filtration efficiency of a filter can be calculated as the sum of the contributions of individual collectors. The resulting HMF model overcomes the limitations of classic mean filtration models which rely on tuning of the mean collector size. Sensitivity analysis shows that the HMF model recovers the classical mean model when the pore size variance is very small. The HMF model is validated by fundamental filtration experimental data from different scales of filter samples. The model shows a good agreement with experimental data at various operating conditions. The effects of the microstructure of filters on filtration efficiency as well as the most penetrating particle size are correctly predicted by the model.
Sievers, David A; Tao, Ling; Schell, Daniel J
2014-09-01
Solid-liquid separation of pretreated lignocellulosic biomass slurries is a critical unit operation employed in several different processes for production of fuels and chemicals. An effective separation process achieves good recovery of solute (sugars) and efficient dewatering of the biomass slurry. Dilute acid pretreated corn stover slurries were subjected to pressure and vacuum filtration and basket centrifugation to evaluate the technical and economic merits of these technologies. Experimental performance results were used to perform detailed process simulations and economic analysis using a 2000 tonne/day biorefinery model to determine differences between the various filtration methods and their process settings. The filtration processes were able to successfully separate pretreated slurries into liquor and solid fractions with estimated sugar recoveries of at least 95% using a cake washing process. A continuous vacuum belt filter produced the most favorable process economics. Copyright © 2014 Elsevier Ltd. All rights reserved.
Choi, Dong Yun; An, Eun Jeong; Jung, Soo-Ho; Song, Dong Keun; Oh, Yong Suk; Lee, Hyung Woo; Lee, Hye Moon
2018-04-10
Through the direct decomposition of an Al precursor ink AlH 3 {O(C 4 H 9 ) 2 }, we fabricated an Al-coated conductive fiber filter for the efficient electrostatic removal of airborne particles (>99%) with a low pressure drop (~several Pascals). The effects of the electrical and structural properties of the filters were investigated in terms of collection efficiency, pressure drop, and particle deposition behavior. The collection efficiency did not show a significant correlation with the extent of electrical conductivity, as the filter is electrostatically charged by the metallic Al layers forming electrical networks throughout the fibers. Most of the charged particles were collected via surface filtration by Coulombic interactions; consequently, the filter thickness had little effect on the collection efficiency. Based on simulations of various fiber structures, we found that surface filtration can transition to depth filtration depending on the extent of interfiber distance. Therefore, the effects of structural characteristics on collection efficiency varied depending on the degree of the fiber packing density. This study will offer valuable information pertaining to the development of a conductive metal/polymer composite air filter for an energy-efficient and high-performance electrostatic filtration system.
Occurrence of Mycobacteria in Water Treatment Lines and in Water Distribution Systems
Le Dantec, Corinne; Duguet, Jean-Pierre; Montiel, Antoine; Dumoutier, Nadine; Dubrou, Sylvie; Vincent, Véronique
2002-01-01
The frequency of recovery of atypical mycobacteria was estimated in two treatment plants providing drinking water to Paris, France, at some intermediate stages of treatment. The two plants use two different filtration processes, rapid and slow sand filtration. Our results suggest that slow sand filtration is more efficient for removing mycobacteria than rapid sand filtration. In addition, our results show that mycobacteria can colonize and grow on granular activated carbon and are able to enter distribution systems. We also investigated the frequency of recovery of mycobacteria in the water distribution system of Paris (outside buildings). The mycobacterial species isolated from the Paris drinking water distribution system are different from those isolated from the water leaving the treatment plants. Saprophytic mycobacteria (present in 41.3% of positive samples), potentially pathogenic mycobacteria (16.3%), and unidentifiable mycobacteria (54.8%) were isolated from 12 sites within the Paris water distribution system. Mycobacterium gordonae was preferentially recovered from treated surface water, whereas Mycobacterium nonchromogenicum was preferentially recovered from groundwater. No significant correlations were found among the presence of mycobacteria, the origin of water, and water temperature. PMID:12406720
Nitsch, Dorothea; Grams, Morgan; Sang, Yingying; Black, Corri; Cirillo, Massimo; Djurdjev, Ognjenka; Iseki, Kunitoshi; Jassal, Simerjot K; Kimm, Heejin; Kronenberg, Florian; Oien, Cecilia M; Levey, Andrew S; Levin, Adeera; Woodward, Mark; Hemmelgarn, Brenda R
2013-01-29
To assess for the presence of a sex interaction in the associations of estimated glomerular filtration rate and albuminuria with all-cause mortality, cardiovascular mortality, and end stage renal disease. Random effects meta-analysis using pooled individual participant data. 46 cohorts from Europe, North and South America, Asia, and Australasia. 2,051,158 participants (54% women) from general population cohorts (n=1,861,052), high risk cohorts (n=151,494), and chronic kidney disease cohorts (n=38,612). Eligible cohorts (except chronic kidney disease cohorts) had at least 1000 participants, outcomes of either mortality or end stage renal disease of ≥ 50 events, and baseline measurements of estimated glomerular filtration rate according to the Chronic Kidney Disease Epidemiology Collaboration equation (mL/min/1.73 m(2)) and urinary albumin-creatinine ratio (mg/g). Risks of all-cause mortality and cardiovascular mortality were higher in men at all levels of estimated glomerular filtration rate and albumin-creatinine ratio. While higher risk was associated with lower estimated glomerular filtration rate and higher albumin-creatinine ratio in both sexes, the slope of the risk relationship for all-cause mortality and for cardiovascular mortality were steeper in women than in men. Compared with an estimated glomerular filtration rate of 95, the adjusted hazard ratio for all-cause mortality at estimated glomerular filtration rate 45 was 1.32 (95% CI 1.08 to 1.61) in women and 1.22 (1.00 to 1.48) in men (P(interaction)<0.01). Compared with a urinary albumin-creatinine ratio of 5, the adjusted hazard ratio for all-cause mortality at urinary albumin-creatinine ratio 30 was 1.69 (1.54 to 1.84) in women and 1.43 (1.31 to 1.57) in men (P(interaction)<0.01). Conversely, there was no evidence of a sex difference in associations of estimated glomerular filtration rate and urinary albumin-creatinine ratio with end stage renal disease risk. Both sexes face increased risk of all-cause mortality, cardiovascular mortality, and end stage renal disease with lower estimated glomerular filtration rates and higher albuminuria. These findings were robust across a large global consortium.
Jeong, Tae-Dong; Cho, Eun-Jung; Lee, Woochang; Chun, Sail; Hong, Ki-Sook; Min, Won-Ki
2017-10-26
The updated bedside Schwartz equation requires constant, serum creatinine concentration and height measurements to calculate the estimated glomerular filtration rate (eGFR) in pediatric patients. Unlike the serum creatinine levels, obtaining height information from the laboratory information system (LIS) is not always possible in a clinical laboratory. Recently, the height-independent eGFR equation, the full age spectrum (FAS) equation, has been introduced. We evaluated the performance of height-independent eGFR equation in Korean children with cancer. A total of 250 children who underwent chromium-51-ethylenediamine tetra acetic-acid (51Cr-EDTA)-based glomerular filtration rate (GFR) measurements were enrolled. The 51Cr-EDTA GFR was used as the reference GFR. The bias (eGFR - measured GFR), precision (root mean square error [RMSE]) and accuracy (P30) of the FAS equations were compared to those of the updated Schwartz equation. P30 was defined as the percentage of patients whose eGFR was within ±30% of the measured GFR. The FAS equation showed significantly lower bias (mL/min/1.73 m2) than the updated Schwartz equation (4.2 vs. 8.7, p<0.001). The RMSE and P30 were: updated Schwartz of 43.8 and 64.4%, respectively, and FAS of 42.7 and 66.8%, respectively. The height-independent eGFR-FAS equation was less biased and as accurate as the updated Schwartz equation in Korean children. The use of the height-independent eGFR equation will allow for efficient reporting of eGFR through the LIS in clinical laboratories.
Li, Peng; Wang, Chunya; Zhang, Yingying; Wei, Fei
2014-11-01
Air filtration in the free molecular flow (FMF) regime is important and challenging because a higher filtration efficiency and lower pressure drop are obtained when the fiber diameter is smaller than the gas mean free path in the FMF regime. In previous studies, FMF conditions have been obtained by increasing the gas mean free path through reducing the pressure and increasing the temperature. In the case of carbon nanotubes (CNTs) with nanoscale diameters, it is possible to filtrate in the FMF regime under normal conditions. This paper reviews recent progress in theoretical and experimental studies of air filtration in the FMF regime. Typical structure models of high-efficiency particulate (HEPA) air filters based on CNTs are introduced. The pressure drop in air filters operated in the FMF regime is less than that predicted by the conventional air filtration theory. The thinnest HEPA filters fabricated from single-walled CNT films have an extremely low pressure drop. CNT air filters with a gradient nanostructure are shown to give a much better filtration performance in dynamic filtration. CNT air filters with a hierarchical structure and an agglomerated CNT fluidized bed air filter are also introduced. Finally, the challenges and opportunities for the application of CNTs in air filtration are discussed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Validation of serum free light chain reference ranges in primary care.
Galvani, Luca; Flanagan, Jane; Sargazi, Mansour; Neithercut, William D
2016-05-01
The demand for measurement of serum immunoglobulin free kappa (κ) and lambda (λ) light chains has increased. The κ:λ ratio is used to assist in diagnosis/monitoring of plasma cell disorders. The binding site reference range for serum-free light chain κ:λ ratios of 0.26-1.65 was derived from healthy volunteers. Subsequently, a reference range of 0.37-3.1 for patients with chronic kidney disease has been proposed. Elevated free light chain concentrations and borderline raised free light chain ratios also may be found in polyclonal gammopathies and with other non-renal illnesses. This assessment was conducted to validate the established free light chain reference ranges in individuals from primary care. A total of 130 samples were identified from routine blood samples collected in primary care for routine biochemistry testing and estimated glomerular filtration rate calculation. The median and range of κ:λ ratios found in each estimated glomerular filtration rate group used for chronic kidney disease classification were higher than previously described. This was the case for individuals with normal or essentially normal renal function with estimated glomerular filtration rates>90, (0.58-1.76) and estimated glomerular filtration rate of 60-90 mL/min/1.73 m(2), (0.71-1.93). Individuals with estimated glomerular filtration rate 15-30, (0.72-4.50) and estimated glomerular filtration rate <15 ml/min/1.73 m(2) (0.71-4.95) also had higher values when compared to the current renal reference range of 0.37-3.10. Elevation of free light chain-κ:λ ratios may occur in the absence of a reduced renal function shown by a normal estimated glomerular filtration rate and in the presence of reduced renal function by estimated glomerular filtration rate when comparing results with the established reference ranges. Explanations include choice of analytical systems or the presence of other concurrent non-plasma cell illness. © The Author(s) 2016.
Uemura, Osamu; Iwata, Naoyuki; Nagai, Takuhito; Yamakawa, Satoshi; Hibino, Satoshi; Yamamoto, Masaki; Nakano, Masaru; Tanaka, Kazuki
2018-05-01
To determine the optimal method of evaluating kidney function in patients with thyroid dysfunction, this study compared the estimated glomerular filtration rate derived from serum creatinine, cystatin C, or β2-microglobulin with inulin or creatinine clearance in two pediatric patients, one with hypothyroidism and the other with hyperthyroidism. It was observed that the kidney function decreased in a hypothyroid child and enhanced in a hyperthyroid child, with their kidney function becoming normalized by treatment with drugs, which normalized their thyroid function. Kidney function cannot be accurately evaluated using cystatin C-based or β2-microglobulin-based estimated glomerular filtration rate in patients with thyroid dysfunction, as these tests overestimated glomerular filtration rate in a patient with hypothyroidism and underestimated glomerular filtration rate in a patient with hyperthyroidism, perhaps through a metabolic rate-mediated mechanism. In both our patients, 24-h urinary creatinine secretion was identical before and after treatment, suggesting that creatinine production is not altered in patients with thyroid dysfunction. Therefore, kidney function in patients with thyroid dysfunction should be evaluated using creatinine-based estimated glomerular filtration rate.
FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS
The filtration efficiency of ventilation air cleaners is highly particle-size dependent over the 0.01 to 3 μm diameter size range. Current standardized test methods, which determine only overall efficiencies for ambient aerosol or other test aerosols, provide data of limited util...
Nitsch, Dorothea; Grams, Morgan; Sang, Yingying; Black, Corri; Cirillo, Massimo; Djurdjev, Ognjenka; Iseki, Kunitoshi; Jassal, Simerjot K; Kimm, Heejin; Kronenberg, Florian; Øien, Cecilia M; Levin, Adeera; Woodward, Mark; Hemmelgarn, Brenda R
2013-01-01
Objective To assess for the presence of a sex interaction in the associations of estimated glomerular filtration rate and albuminuria with all-cause mortality, cardiovascular mortality, and end stage renal disease. Design Random effects meta-analysis using pooled individual participant data. Setting 46 cohorts from Europe, North and South America, Asia, and Australasia. Participants 2 051 158 participants (54% women) from general population cohorts (n=1 861 052), high risk cohorts (n=151 494), and chronic kidney disease cohorts (n=38 612). Eligible cohorts (except chronic kidney disease cohorts) had at least 1000 participants, outcomes of either mortality or end stage renal disease of ≥50 events, and baseline measurements of estimated glomerular filtration rate according to the Chronic Kidney Disease Epidemiology Collaboration equation (mL/min/1.73 m2) and urinary albumin-creatinine ratio (mg/g). Results Risks of all-cause mortality and cardiovascular mortality were higher in men at all levels of estimated glomerular filtration rate and albumin-creatinine ratio. While higher risk was associated with lower estimated glomerular filtration rate and higher albumin-creatinine ratio in both sexes, the slope of the risk relationship for all-cause mortality and for cardiovascular mortality were steeper in women than in men. Compared with an estimated glomerular filtration rate of 95, the adjusted hazard ratio for all-cause mortality at estimated glomerular filtration rate 45 was 1.32 (95% CI 1.08 to 1.61) in women and 1.22 (1.00 to 1.48) in men (Pinteraction<0.01). Compared with a urinary albumin-creatinine ratio of 5, the adjusted hazard ratio for all-cause mortality at urinary albumin-creatinine ratio 30 was 1.69 (1.54 to 1.84) in women and 1.43 (1.31 to 1.57) in men (Pinteraction<0.01). Conversely, there was no evidence of a sex difference in associations of estimated glomerular filtration rate and urinary albumin-creatinine ratio with end stage renal disease risk. Conclusions Both sexes face increased risk of all-cause mortality, cardiovascular mortality, and end stage renal disease with lower estimated glomerular filtration rates and higher albuminuria. These findings were robust across a large global consortium. PMID:23360717
Fernandez-Prado, Raul; Castillo-Rodriguez, Esmeralda; Velez-Arribas, Fernando Javier; Gracia-Iguacel, Carolina; Ortiz, Alberto
2016-12-01
Direct oral anticoagulants (DOACs) may require dose reduction or avoidance when glomerular filtration rate is low. However, glomerular filtration rate is not usually measured in routine clinical practice. Rather, equations that incorporate different variables use serum creatinine to estimate either creatinine clearance in mL/min or glomerular filtration rate in mL/min/1.73 m 2 . The Cockcroft-Gault equation estimates creatinine clearance and incorporates weight into the equation. By contrast, the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations estimate glomerular filtration rate and incorporate ethnicity but not weight. As a result, an individual patient may have very different renal function estimates, depending on the equation used. We now highlight these differences and discuss the impact on routine clinical care for anticoagulation to prevent embolization in atrial fibrillation. Pivotal DOAC clinical trials used creatinine clearance as a criterion for patient enrollment, and dose adjustment and Federal Drug Administration recommendations are based on creatinine clearance. However, clinical biochemistry laboratories provide CKD-EPI glomerular filtration rate estimations, resulting in discrepancies between clinical trial and routine use of the drugs. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gong, Jian; Stewart, Mark L.; Zelenyuk, Alla
The state-of-the-art multiscale modeling of GPFs including channel scale, wall scale, and pore scale is described. The microstructures of two GPFs were experimentally characterized. The pore size distributions of the GPFs were determined by mercury porosimetry. The porosity was measured by X-ray computed tomography (CT) and found to be inhomogeneous across the substrate wall. The significance of pore size distribution with respect to filtration performance was analyzed. The predictions of filtration efficiency were improved by including the pore size distribution in the filtration model. A dynamic heterogeneous multiscale filtration (HMF) model was utilized to simulate particulate filtration on a singlemore » channel particulate filter with realistic particulate emissions from a spark-ignition direct-injection (SIDI) gasoline engine. The dynamic evolution of filter’s microstructure and macroscopic filtration characteristics including mass- and number-based filtration efficiencies and pressure drop were predicted and discussed. The microstructure of the GPF substrate including inhomogeneous porosity and pore size distribution is found to significantly influence local particulate deposition inside the substrate and macroscopic filtration performance and is recommended to be resolved in the filtration model to simulate and evaluate the filtration performance of GPFs.« less
Ng, Bing Feng; Xiong, Jin Wen; Wan, Man Pun
2017-01-01
The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV) systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency.
Xiong, Jin Wen; Wan, Man Pun
2017-01-01
The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV) systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency. PMID:28594862
Gong, Jian; Stewart, Mark L.; Zelenyuk, Alla; ...
2018-01-03
The state-of-the-art multiscale modeling of gasoline particulate filter (GPF) including channel scale, wall scale, and pore scale is described. The microstructures of two GPFs were experimentally characterized. The pore size distributions of the GPFs were determined by mercury porosimetry. The porosity was measured by X-ray computed tomography (CT) and found to be inhomogeneous across the substrate wall. The significance of pore size distribution with respect to filtration performance was analyzed. The predictions of filtration efficiency were improved by including the pore size distribution in the filtration model. A dynamic heterogeneous multiscale filtration (HMF) model was utilized to simulate particulate filtrationmore » on a single channel particulate filter with realistic particulate emissions from a spark-ignition direct-injection (SIDI) gasoline engine. The dynamic evolution of filter’s microstructure and macroscopic filtration characteristics including mass- and number-based filtration efficiencies and pressure drop were predicted and discussed. In conclusion, the microstructure of the GPF substrate including inhomogeneous porosity and pore size distribution is found to significantly influence local particulate deposition inside the substrate and macroscopic filtration performance and is recommended to be resolved in the filtration model to simulate and evaluate the filtration performance of GPFs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gong, Jian; Stewart, Mark L.; Zelenyuk, Alla
The state-of-the-art multiscale modeling of gasoline particulate filter (GPF) including channel scale, wall scale, and pore scale is described. The microstructures of two GPFs were experimentally characterized. The pore size distributions of the GPFs were determined by mercury porosimetry. The porosity was measured by X-ray computed tomography (CT) and found to be inhomogeneous across the substrate wall. The significance of pore size distribution with respect to filtration performance was analyzed. The predictions of filtration efficiency were improved by including the pore size distribution in the filtration model. A dynamic heterogeneous multiscale filtration (HMF) model was utilized to simulate particulate filtrationmore » on a single channel particulate filter with realistic particulate emissions from a spark-ignition direct-injection (SIDI) gasoline engine. The dynamic evolution of filter’s microstructure and macroscopic filtration characteristics including mass- and number-based filtration efficiencies and pressure drop were predicted and discussed. In conclusion, the microstructure of the GPF substrate including inhomogeneous porosity and pore size distribution is found to significantly influence local particulate deposition inside the substrate and macroscopic filtration performance and is recommended to be resolved in the filtration model to simulate and evaluate the filtration performance of GPFs.« less
Reed, Mike; Kimberger, Oliver; McGovern, Paul D; Albrecht, Mark C
2013-08-01
Forced-air warming devices are effective for the prevention of surgical hypothermia. However, these devices intake nonsterile floor-level air, and it is unknown whether they have adequate filtration measures to prevent the internal buildup or emission of microbial contaminants. We rated the intake filtration efficiency of a popular current-generation forced-air warming device (Bair Hugger model 750, Arizant Healthcare) using a monodisperse sodium chloride aerosol in the laboratory. We further sampled 23 forced-air warming devices (same model) in daily hospital use for internal microbial buildup and airborne-contamination emissions via swabbing and particle counting. Laboratory testing found the intake filter to be 63.8% efficient. Swabbing detected microorganisms within 100% of the forced-air warming blowers sampled, with isolates of coagulase-negative staphylococci, mold, and micrococci identified. Particle counting showed 96% of forced-air warming blowers to be emitting significant levels of internally generated airborne contaminants out of the hose end. These findings highlight the need for upgraded intake filtration, preferably high-efficiency particulate air filtration (99.97% efficient), on current-generation forced-air warming devices to reduce contamination buildup and emission risks.
Deen, John; Cano, Jean Paul; Batista, Laura; Pijoan, Carlos
2006-01-01
Abstract The purpose of this study was to compare 4 methods for the reduction of aerosol transmission of Porcine reproductive and respiratory syndrome virus (PRRSV): high-efficiency particulate air (HEPA) filtration, 2×-low-cost filtration, bag filtration, and use of a filter tested against particles derived from dioctylphthalate (DOP). The HEPA-filtration system used a prefilter screen, a bag filter (Eurovent [EU] 8 rating), and a HEPA filter (EU13 rating). The low-cost-filtration system contained mosquito netting (prefilter), 2 fiberglass furnace filters, and 2 electrostatic furnace filters. Bag filtration involved the use of a filter rated EU8 and a minimum efficiency reporting value (MERV) of 14. The 95%-DOP, 0.3-μm-filtration system involved a pleat-in-pleat V-bank disposable filter with a 95% efficiency rating for particles 0.3 μm or greater in diameter and ratings of EU9 and MERV 15. No form of intervention was used in the control group. The experimental facilities consisted of 2 chambers connected by a 1.3-m-long duct containing the treatments. Recipient pigs, housed in chamber 2, were exposed to artificial aerosols created by a mechanically operated mister containing modified live PRRSV vaccine located in chamber 1. Aerosol transmission of PRRSV occurred in 0 of the 10 HEPA-filtration replicates, 2 of the 10 bag-filtration replicates, 4 of the 10 low-cost-filtration replicates, 0 of the 10 95%-DOP, 0.3-μm-filtration replicates, and all 10 of the control replicates. Using a similar approach, we further evaluated the HEPA- and 95%-DOP, 0.3-μm-filtration systems. Infection was not observed in any of the 76 HEPA-filtration replicates but was observed in 2 of the 76 95%-DOP, 0.3-μm replicates and 42 of the 50 control replicates. Although the difference between the 95%-DOP, 0.3-μm and control replicates was significant (P < 0.0005), so was the level of failure of the 95%-DOP, 0.3-μm system (P = 0.02). In conclusion, under the conditions of this study, some methods of air filtration were significantly better than others in reducing aerosol transmission of PRRSV, and HEPA filtration was the only system that completely prevented transmission. PMID:16850938
Increase of Total Nephron Albumin Filtration and Reabsorption in Diabetic Nephropathy.
Mori, Keita P; Yokoi, Hideki; Kasahara, Masato; Imamaki, Hirotaka; Ishii, Akira; Kuwabara, Takashige; Koga, Kenichi; Kato, Yukiko; Toda, Naohiro; Ohno, Shoko; Kuwahara, Koichiro; Endo, Tomomi; Nakao, Kazuwa; Yanagita, Motoko; Mukoyama, Masashi; Mori, Kiyoshi
2017-01-01
The amount of albumin filtered through the glomeruli and reabsorbed at the proximal tubules in normal and in diabetic kidneys is debated. The megalin/cubilin complex mediates protein reabsorption, but genetic knockout of megalin is perinatally lethal. To overcome current technical problems, we generated a drug-inducible megalin-knockout mouse line, megalin(lox/lox);Ndrg1-CreER T2 (iMegKO), in which megalin expression can be shut off at any time by administration of tamoxifen (Tam). Tam administration in adult iMegKO mice decreased the expression of renal megalin protein by 92% compared with that in wild-type C57BL/6J mice and almost completely abrogated renal reabsorption of intravenously injected retinol-binding protein. Furthermore, urinary albumin excretion increased to 175 μg/d (0.46 mg albumin/mg creatinine) in Tam-treated iMegKO mice, suggesting that this was the amount of total nephron albumin filtration. By comparing Tam-treated, streptozotocin-induced diabetic iMegKO mice with Tam-treated nondiabetic iMegKO mice, we estimated that the development of diabetes led to a 1.9-fold increase in total nephron albumin filtration, a 1.8-fold increase in reabsorption, and a significant reduction in reabsorption efficiency (86% efficiency versus 96% efficiency in nondiabetic mice). Insulin treatment normalized these abnormalities. Akita;iMegKO mice, another model of type 1 diabetes, showed equivalent results. Finally, nondiabetic iMegKO mice had a glomerular sieving coefficient of albumin of 1.7×10 -5 , which approximately doubled in diabetic iMegKO mice. This study reveals actual values and changes of albumin filtration and reabsorption in early diabetic nephropathy in mice, bringing new insights to our understanding of renal albumin dynamics associated with the hyperfiltration status of diabetic nephropathy. Copyright © 2016 by the American Society of Nephrology.
Estimation of single-kidney glomerular filtration rate without exogenous contrast agent.
He, Xiang; Aghayev, Ayaz; Gumus, Serter; Ty Bae, K
2014-01-01
Measurement of single-kidney filtration fraction and glomerular filtration rate (GFR) without exogenous contrast is clinically important to assess renal function and pathophysiology, especially for patients with comprised renal function. The objective of this study is to develop a novel MR-based tool for noninvasive quantification of renal function using conventional MR arterial spin labeling water as endogenous tracer. The regional differentiation of the arterial spin labeling water between the glomerular capsular space and the renal parenchyma was characterized and measured according to their MR relaxation properties (T1ρ or T2 ), and applied to the estimation of filtration fraction and single-kidney GFR. The proposed approach was tested to quantify GFR in healthy volunteers at baseline and after a protein-loading challenge. Biexponential decay of the cortical arterial spin labeling water MR signal was observed. The major component decays the same as parenchyma water; the minor component decays much slower as expected from glomerular ultra-filtrates. The mean single-kidney GFR was estimated to be 49 ± 9 mL/min at baseline and increased by 28% after a protein-loading challenge. We developed an arterial spin labeling-based MR imaging method that allows us to estimate renal filtration fraction and singe-kidney GFR without use of exogenous contrast. Copyright © 2013 Wiley Periodicals, Inc.
Shikanov, Sergey; Clark, Melanie A; Raman, Jay D; Smith, Benjamin; Kaag, Matthew; Russo, Paul; Wheat, Jeffrey C; Wolf, J Stuart; Huang, William C; Shalhav, Arieh L; Eggener, Scott E
2010-11-01
A novel equation, the Chronic Kidney Disease Epidemiology Collaboration, has been proposed to replace the Modification of Diet in Renal Disease for estimated glomerular filtration rate due to higher accuracy, particularly in the setting of normal renal function. We compared these equations in patients with 2 functioning kidneys undergoing partial nephrectomy. We assembled a cohort of 1,158 patients from 5 institutions who underwent partial nephrectomy between 1991 and 2009. Only subjects with 2 functioning kidneys were included in the study. The end points were baseline estimated glomerular filtration rate, last followup estimated glomerular filtration rate (3 to 18 months), absolute and percent change estimated glomerular filtration rate ([absolute change/baseline] × 100%), and proportion of newly developed chronic kidney disease stage III. The agreement between the equations was evaluated using Bland-Altman plots and the McNemar test for paired observations. Mean baseline estimated glomerular filtration rate derived from the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration equations were 73 and 77 ml/minute/1.73 m(2), respectively, and following surgery were 63 and 67 ml/minute/1.73 m(2), respectively. Mean percent change estimated glomerular filtration rate was -12% for both equations (p = 0.2). The proportion of patients with newly developed chronic kidney disease stage III following surgery was 32% and 25%, according to the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration equations, respectively (p = 0.001). For patients with 2 functioning kidneys undergoing partial nephrectomy the Chronic Kidney Disease Epidemiology Collaboration equation provides slightly higher glomerular filtration rate estimates compared to the Modification of Diet in Renal Disease equation, with 7% fewer patients categorized as having chronic kidney disease stage III or worse. Copyright © 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Liu, Bowen; Zhang, Shichao; Wang, Xueli; Yu, Jianyong; Ding, Bin
2015-11-01
Nanofibrous media that both possess high airborne particle interception efficiency and robust air permeability would have broad technological implications for areas ranging from individual protection and industrial security to environmental governance; however, creating such filtration media has proved extremely challenging. Here we report a strategy to construct the bio-based polyamide-56 nanofiber/nets (PA-56 NFN) membranes with bimodal structures for effective air filtration via one-step electrospinning/netting. The PA-56 membranes are composed of completely covered two-dimensional (2D) ultrathin (∼20 nm) nanonets which are optimized by facilely regulating the solution concentration, and the bonded scaffold fibers constructed cavity structures which are synchronously created by using the CH3COOH inspiration. With integrated properties of small aperture, high porosity, and bonded scaffold, the resulting PA-56 NFN membranes exhibit high filtration efficiency of 99.995%, low pressure drop of 111 Pa, combined with large dust holding capacity of 49 g/m(2) and dust-cleaning regeneration ability, for filtrating ultrafine airborne particles in the most safe manner involving sieving principle and surface filtration. The successful synthesis of PA-56 NFN medium would not only make it a promising candidate for air filtration, but also provide new insights into the design and development of nanonet-based bimodal structures for various applications. Copyright © 2015 Elsevier Inc. All rights reserved.
Novel Filtration Markers for GFR Estimation
Inker, Lesley A.; Coresh, Josef; Levey, Andrew S.; Eckfeldt, John H.
2017-01-01
Creatinine-based glomerular filtration rate estimation (eGFRcr) has been improved and refined since the 1970s through both the Modification of Diet in Renal Disease (MDRD) Study equation in 1999 and the CKD Epidemiology Collaboration (CKD-EPI) equation in 2009, with current clinical practice dependent primarily on eGFR for accurate assessment of GFR. However, researchers and clinicians have recognized limitations of relying on creatinine as the only filtration marker, which can lead to inaccurate GFR estimates in certain populations due to the influence of non-GFR determinants of serum or plasma creatinine. Therefore, recent literature has proposed incorporation of multiple serum or plasma filtration markers into GFR estimation to improve precision and accuracy and decrease the impact of non-GFR determinants for any individual biomarker. To this end, the CKD-EPI combined creatinine-cystatin C equation (eGFRcr-cys) was developed in 2012 and demonstrated superior accuracy to equations relying on creatinine or cystatin C alone (eGFRcr or eGFRcys). Now, the focus has broadened to include additional novel filtration markers to further refine and improve GFR estimation. Beta-2-microglobulin (B2M) and beta-trace-protein (BTP) are two filtration markers with established assays that have been proposed as candidates for improving both GFR estimation and risk prediction. GFR estimating equations based on B2M and BTP have been developed and validated, with the CKD-EPI combined BTP-B2M equation (eGFRBTP-B2M) demonstrating similar performance to eGFR and eGFR. Additionally, several studies have demonstrated that both B2M and BTP are associated with outcomes in CKD patients, including cardiovascular events, ESRD and mortality. This review will primarily focus on these two biomarkers, and will highlight efforts to identify additional candidate biomarkers through metabolomics-based approaches. PMID:29333147
Exploration of PM2.5 filtration property of filter bag for environment protection
NASA Astrophysics Data System (ADS)
Zhu, Ruitian; Zheng, Jinwei; Ni, Bingxuan; Zhang, Peng
2017-06-01
In this paper, filter bag of polyphenylene sulfide (PPS) needle punched nonwoven for environment protection was investigated. The results showed that air permeability of sample was linear rise with the increase of the pressure drop. During the testing process, the residual pressure drop rose with the increase of cycles because of test dust attaching on the surface of the filter. The PM2.5 filtration efficiency was obtained of 99.854%, which was smaller than the dust filtration efficiency of 99.971% because of the fine particles taking larger proportion of the dust through the sample. Results show that this method of evaluating the PM2.5 filtration property is feasible.
EFFECT OF LOADING DUST TYPE ON THE FILTRATION EFFICIENCY OF ELECTROSTATICALLY CHARGED FILTERS
The paper gives results of an evaluation of the effect of loading dust type on the filtration efficiency of electrostatically charged filters. Three types of filters were evaluated: a rigid-cell filter charged using an electrodynamic spinning process, a pleated-panel filter cha...
Silver nanoparticle-doped zirconia capillaries for enhanced bacterial filtration.
Wehling, Julia; Köser, Jan; Lindner, Patrick; Lüder, Christian; Beutel, Sascha; Kroll, Stephen; Rezwan, Kurosch
2015-03-01
Membrane clogging and biofilm formation are the most serious problems during water filtration. Silver nanoparticle (Agnano) coatings on filtration membranes can prevent bacterial adhesion and the initiation of biofilm formation. In this study, Agnano are immobilized via direct reduction on porous zirconia capillary membranes to generate a nanocomposite material combining the advantages of ceramics being chemically, thermally and mechanically stable with nanosilver, an efficient broadband bactericide for water decontamination. The filtration of bacterial suspensions of the fecal contaminant Escherichia coli reveals highly efficient bacterial retention capacities of the capillaries of 8 log reduction values, fulfilling the requirements on safe drinking water according to the U.S. Environmental Protection Agency. Maximum bacterial loading capacities of the capillary membranes are determined to be 3×10(9)bacterialcells/750mm(2) capillary surface until back flushing is recommendable. The immobilized Agnano remain accessible and exhibit strong bactericidal properties by killing retained bacteria up to maximum bacterial loads of 6×10(8)bacterialcells/750mm(2) capillary surface and the regenerated membranes regain filtration efficiencies of 95-100%. Silver release is moderate as only 0.8% of the initial silver loading is leached during a three-day filtration experiment leading to average silver contaminant levels of 100μg/L. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Perrier, E. M. A.; Bird, N. R. A.; Rieutord, T. B.
2010-04-01
Quantifying the connectivity of pore networks is a key issue not only for modelling fluid flow and solute transport in porous media but also for assessing the ability of soil ecosystems to filter bacteria, viruses and any type of living microorganisms as well inert particles which pose a contamination risk. Straining is the main mechanical component of filtration processes: it is due to size effects, when a given soil retains a conveyed entity larger than the pores through which it is attempting to pass. We postulate that the range of sizes of entities which can be trapped inside soils has to be associated with the large range of scales involved in natural soil structures and that information on the pore size distribution has to be complemented by information on a Critical Filtration Size (CFS) delimiting the transition between percolating and non percolating regimes in multiscale pore networks. We show that the mass fractal dimensions which are classically used in soil science to quantify scaling laws in observed pore size distributions can also be used to build 3-D multiscale models of pore networks exhibiting such a critical transition. We extend to the 3-D case a new theoretical approach recently developed to address the connectivity of 2-D fractal networks (Bird and Perrier, 2009). Theoretical arguments based on renormalisation functions provide insight into multi-scale connectivity and a first estimation of CFS. Numerical experiments on 3-D prefractal media confirm the qualitative theory. These results open the way towards a new methodology to estimate soil filtration efficiency from the construction of soil structural models to be calibrated on available multiscale data.
NASA Astrophysics Data System (ADS)
Perrier, E. M. A.; Bird, N. R. A.; Rieutord, T. B.
2010-10-01
Quantifying the connectivity of pore networks is a key issue not only for modelling fluid flow and solute transport in porous media but also for assessing the ability of soil ecosystems to filter bacteria, viruses and any type of living microorganisms as well inert particles which pose a contamination risk. Straining is the main mechanical component of filtration processes: it is due to size effects, when a given soil retains a conveyed entity larger than the pores through which it is attempting to pass. We postulate that the range of sizes of entities which can be trapped inside soils has to be associated with the large range of scales involved in natural soil structures and that information on the pore size distribution has to be complemented by information on a critical filtration size (CFS) delimiting the transition between percolating and non percolating regimes in multiscale pore networks. We show that the mass fractal dimensions which are classically used in soil science to quantify scaling laws in observed pore size distributions can also be used to build 3-D multiscale models of pore networks exhibiting such a critical transition. We extend to the 3-D case a new theoretical approach recently developed to address the connectivity of 2-D fractal networks (Bird and Perrier, 2009). Theoretical arguments based on renormalisation functions provide insight into multi-scale connectivity and a first estimation of CFS. Numerical experiments on 3-D prefractal media confirm the qualitative theory. These results open the way towards a new methodology to estimate soil filtration efficiency from the construction of soil structural models to be calibrated on available multiscale data.
Joe, Yun Haeng; Woo, Kyoungja; Hwang, Jungho
2014-09-15
In this study, SiO2 nanoparticles surface coated with Ag nanoparticles (SA particles) were fabricated to coat a medium air filter. The pressure drop, filtration efficiency, and anti-viral ability of the filter were evaluated against aerosolized bacteriophage MS2 in a continuous air flow condition. A mathematical approach was developed to measure the anti-viral ability of the filter with various virus deposition times. Moreover, two quality factors based on the anti-viral ability of the filter, and a traditional quality factor based on filtration efficiency, were calculated. The filtration efficiency and pressure drop increased with decreasing media velocity and with increasing SA particle coating level. The anti-viral efficiency also increased with increasing SA particle coating level, and decreased by with increasing virus deposition time. Consequently, SA particle coating on a filter does not have significant effects on filtration quality, and there is an optimal coating level to produce the highest anti-viral quality. Copyright © 2014 Elsevier B.V. All rights reserved.
Paig-Tran, E W Misty; Bizzarro, Joseph J; Strother, James A; Summers, Adam P
2011-05-15
We created physical models based on the morphology of ram suspension-feeding fishes to better understand the roles morphology and swimming speed play in particle retention, size selectivity and filtration efficiency during feeding events. We varied the buccal length, flow speed and architecture of the gills slits, including the number, size, orientation and pore size/permeability, in our models. Models were placed in a recirculating flow tank with slightly negatively buoyant plankton-like particles (~20-2000 μm) collected at the simulated esophagus and gill rakers to locate the highest density of particle accumulation. Particles were captured through sieve filtration, direct interception and inertial impaction. Changing the number of gill slits resulted in a change in the filtration mechanism of particles from a bimodal filter, with very small (≤ 50 μm) and very large (>1000 μm) particles collected, to a filter that captured medium-sized particles (101-1000 μm). The number of particles collected on the gill rakers increased with flow speed and skewed the size distribution towards smaller particles (51-500 μm). Small pore sizes (105 and 200 μm mesh size) had the highest filtration efficiencies, presumably because sieve filtration played a significant role. We used our model to make predictions about the filtering capacity and efficiency of neonatal whale sharks. These results suggest that the filtration mechanics of suspension feeding are closely linked to an animal's swimming speed and the structural design of the buccal cavity and gill slits.
Wang, Haolun; Lin, Sen; Yang, Shen; Yang, Xudong; Song, Jianan; Wang, Dong; Wang, Haiyang; Liu, Zhenglian; Li, Bo; Fang, Minghao; Wang, Ning; Wu, Hui
2018-05-01
Particulate matter (PM) is a major air pollutant in many regions, jeopardizing ecosystems and public health. Filtration at pollutant source is one of the most important ways to protect the environment, however, considering the high-temperature exhaust gas emissions, effective removal of PM and related pollutants from their sources remains a major challenge. In this study, a resilient, heat-resisting, and high-efficiency PM filter based on yttria-stabilized ZrO 2 (YSZ) nanofiber sponge produced with a scalable solution blow spinning process is reported. The porous 3D sponge composed of YSZ nanofibers is lightweight (density of 20 mg cm -3 ) and resilient at both room temperature and high temperatures. At room-temperature conditions, the YSZ nanofiber sponge exhibits 99.4% filtration efficiency for aerosol particles with size in the range of 20-600 nm, associated with a low pressure drop of only 57 Pa under an airflow velocity of 4.8 cm s -1 . At a high temperature of 750 °C, the ceramic sponge maintains a high filtration efficiency of 99.97% for PM 0.3-2.5 under a high airflow velocity of 10 cm s -1 . A practical vehicle exhaust filter to capture particles with filtration efficiency of >98.3% is also assembled. Hence, the YSZ nanofiber sponge has enormous potential to be applied in industry. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Copic, Davor; Maggini, Laura; De Volder, Michael
2018-03-01
Carbon nanotube (CNT)-based filters have the potential to revolutionize water treatment because of their high capacity and fast kinetics in sorption of organic, inorganic, and biological pollutants. To date, CNT filters either rely on CNTs dispersed in liquids, which are difficult to recover and cause safety concerns, or on CNT buckypaper, which offers high efficiency, but suffers from an intrinsic trade-off between filter permeability and capacity. Here, a new approach is presented that bypasses this trade-off and achieves buckypaper-like efficiency combined with filter-column-like permeability and capacity. For this, CNTs are first assembled into porous microspheres and then are packed into microfluidic column filters. These microcolumns exhibit large flow-through filtration efficiencies, while maintaining membrane permeabilities an order of magnitude larger then CNT buckypaper and specific permeabilities double that of activated carbon for similar flowrates (232 000 L m -2 h -1 bar -1 , 1.23 × 10 -12 m 2 ). Moreover, in a test to remove sodium dodecyl sulfate (SDS) from water, these microstructured CNT columns outperform activated carbon columns. This improved filtration efficiency and permeability is an important step toward a broader implementation of CNT-based filtration devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gholikandi, G Badalians; Dehghanifard, E; Sepehr, M Noori; Torabian, A; Moalej, S; Dehnavi, A; Yari, Ar; Asgari, Ar
2012-01-01
Water filtration units have been faced problems in water turbidity removal related to their media, which is determined by qualitative indices. Moreover, Current qualitative indices such as turbidity and escaping particle number could not precisely determine the efficiency of the media in water filtration, so defining new indices is essential. In this study, the efficiency of Anthracite-Silica and LECA-Silica media in turbidity removal were compared in different operating condition by using modified qualitative indices. The pilot consisted of a filter column (one meter depth) which consisted of a layer of LECA (450 mm depth) and a layer of Silica sand (350 mm depth. Turbidities of 10, 20, and 30 NTU, coagulant concentrations of 4, 8, and 12 ppm and filtration rates of 10, 15, and 20 m/h were considered as variables. The LECA-Silica media is suitable media for water filtration. Averages of turbidity removal efficiencies in different condition for the LECA-Silica media were 85.8±5.37 percent in stable phase and 69.75±3.37 percent in whole operation phase, while the efficiency of total system were 98.31±0.63 and 94.49±2.97 percent, respectively. The LECA layer efficiency in turbidity removal was independent from filtration rates and due to its low head loss; LECA can be used as a proper medium for treatment plants. Results also showed that the particle index (PI) was a suitable index as a substitute for turbidity and EPN indices.
Performance of ultrafiltration membrane process combined with coagulation/sedimentation.
Jang, N Y; Watanabe, Y; Minegishi, S
2005-01-01
Effects of coagulation/sedimentation as a pre-treatment on the dead-end ultrafiltration (UF) membrane process were studied in terms of membrane fouling and removal efficiency of natural dissolved organic matter, using Chitose River water. Two types of experiment were carried out. One was a bench scale membrane filtration with jar-test and the other was membrane filtration pilot plant combined with the Jet Mixed Separator (JMS) as a pre-coagulation/sedimentation unit. In the bench scale experiment, the effects of coagulant dosage, pH and membrane operating pressure on the membrane fouling and removal efficiency of natural dissolved organic matter were investigated. In the pilot plant experiment, we also investigated the effect of pre-coagulation/sedimentation on the membrane fouling and the removal efficiency of natural dissolved organic matter. Coagulation/sedimentation prior to membrane filtration process controlled the membrane fouling and increased the removal efficiency of natural dissolved organic matter.
Kegel, F Schoonenberg; Rietman, B M; Verliefde, A R D
2010-01-01
Drinking water utilities in Europe are faced with a growing presence of organic micropollutants in their water sources. The aim of this research was to assess the robustness of a drinking water treatment plant equipped with reverse osmosis and subsequent activated carbon filtration for the removal of these pollutants. The total removal efficiency of 47 organic micropollutants was investigated. Results indicated that removal of most organic micropollutants was high for all membranes tested. Some selected micropollutants were less efficiently removed (e.g. the small and polar NDMA and glyphosate, and the more hydrophobic ethylbenzene and napthalene). Very high removal efficiencies for almost all organic micropollutants by the subsequent activated carbon, fed with the permeate stream of the RO element were observed except for the very small and polar NDMA and 1,4-dioxane. RO and subsequent activated carbon filtration are complementary and their combined application results in the removal of a large part of these emerging organic micropollutants. Based on these experiments it can be concluded that the robustness of a proposed treatment scheme for the drinking water treatment plant Engelse Werk is sufficiently guaranteed.
Tiong, H Y; Goldfarb, D A; Kattan, M W; Alster, J M; Thuita, L; Yu, C; Wee, A; Poggio, E D
2009-03-01
We developed nomograms that predict transplant renal function at 1 year (Modification of Diet in Renal Disease equation [estimated glomerular filtration rate]) and 5-year graft survival after living donor kidney transplantation. Data for living donor renal transplants were obtained from the United Network for Organ Sharing registry for 2000 to 2003. Nomograms were designed using linear or Cox regression models to predict 1-year estimated glomerular filtration rate and 5-year graft survival based on pretransplant information including demographic factors, immunosuppressive therapy, immunological factors and organ procurement technique. A third nomogram was constructed to predict 5-year graft survival using additional information available by 6 months after transplantation. These data included delayed graft function, any treated rejection episodes and the 6-month estimated glomerular filtration rate. The nomograms were internally validated using 10-fold cross-validation. The renal function nomogram had an r-square value of 0.13. It worked best when predicting estimated glomerular filtration rate values between 50 and 70 ml per minute per 1.73 m(2). The 5-year graft survival nomograms had a concordance index of 0.71 for the pretransplant nomogram and 0.78 for the 6-month posttransplant nomogram. Calibration was adequate for all nomograms. Nomograms based on data from the United Network for Organ Sharing registry have been validated to predict the 1-year estimated glomerular filtration rate and 5-year graft survival. These nomograms may facilitate individualized patient care in living donor kidney transplantation.
Zabor, Emily C; Furberg, Helena; Lee, Byron; Campbell, Steven; Lane, Brian R; Thompson, R Houston; Antonio, Elvis Caraballo; Noyes, Sabrina L; Zaid, Harras; Jaimes, Edgar A; Russo, Paul
2018-04-01
We sought to confirm the findings from a previous single institution study of 572 patients from Memorial Sloan Kettering Cancer Center in which we found that 49% of patients recovered to the preoperative estimated glomerular filtration rate within 2 years following radical nephrectomy for renal cell carcinoma. A multicenter retrospective study was performed in 1,928 patients using data contributed from 3 independent centers. The outcome of interest was postoperative recovery to the preoperative estimated glomerular filtration rate. Data were analyzed using cumulative incidence and competing risks regression with death from any cause treated as a competing event. This study demonstrated that 45% of patients had recovered to the preoperative estimated glomerular filtration rate by 2 years following radical nephrectomy. Furthermore, this study confirmed that recovery of renal function differed according to preoperative renal function such that patients with a lower preoperative estimated glomerular filtration rate had an increased chance of recovery. This study also suggested that larger tumor size and female gender were significantly associated with an increased chance of renal function recovery. In this multicenter retrospective study we confirmed that in the long term a large proportion of patients recover to preoperative renal function following radical nephrectomy for kidney tumors. Recovery is more likely among those with a lower preoperative estimated glomerular filtration rate. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Exploration of Ultralight Nanofiber Aerogels as Particle Filters: Capacity and Efficiency.
Deuber, Fabian; Mousavi, Sara; Federer, Lukas; Hofer, Marco; Adlhart, Christian
2018-03-14
Ultralight nanofiber aerogels (NFAs) or nanofiber sponges are a truly three-dimensional derivative of the intrinsically flat electrospun nanofiber mats or membranes (NFMs). Here we investigated the potential of such materials for particle or aerosol filtration because particle filtration is a major application of NFMs. Ultralight NFAs were synthesized from electrospun nanofibers using a solid-templating technique. These materials had a tunable hierarchical cellular open-pore structure. We observed high filtration efficiencies of up to 99.999% at the most penetrating particle size. By tailoring the porosity of the NFAs through the processing parameters, we were able to adjust the number of permeated particles by a factor of 1000 and the pressure drop by a factor of 9. These NFAs acted as a deep-bed filter, and they were capable of handling high dust loadings without any indication of performance loss or an increase in the pressure drop. When the face velocity was increased from 0.75 to 6 cm s -1 , the filtration efficiency remained high within a factor of 1.1-10. Both characteristics were in contrast to the behavior of two commercial NFM particle filters, which showed significant increases in the pressure drop with the filtration time as well as a susceptibility against high face velocities by a factor of 105.
Contribution of stone size to chronic kidney disease in kidney stone formers.
Ahmadi, Farrokhlagha; Etemadi, Samira Motedayen; Lessan-Pezeshki, Mahbob; Mahdavi-Mazdeh, Mitra; Ayati, Mohsen; Mir, Alireza; Yazdi, Hadi Rokni
2015-01-01
To determine whether stone burden correlates with the degree of chronic kidney disease in kidney stone formers. A total of 97 extracorporeal shockwave lithotripsy candidates aged 18 years and older were included. Size, number and location of the kidney stones, along with cumulative stone size, defined as the sum of diameters of all stones) were determined. Estimated glomerular filtration rate was determined using the Chronic Kidney Disease Epidemiology Collaboration cystatin C/creatinine equation, and chronic kidney disease was defined as estimated glomerular filtration rate <60 mL/min/1.73 m(2). In individuals with cumulative stone size <20 mm, estimated glomerular filtration rate significantly decreased when moving from the first (estimated glomerular filtration rate 75.5 ± 17.8 mL/min/1.73 m(2)) to the fourth (estimated glomerular filtration rate 56.4 ± 20.44 mL/min/1.73 m(2) ) quartile (P = 0.004). When patients with a cumulative stone size ≥ 20 mm were included, the observed association was rendered non-significant. In individuals with a cumulative stone size < 20 mm, each 1-mm increase in cumulative stone size was associated with a 20% increased risk of having chronic kidney disease. The relationship persisted even after adjustment for age, sex, body mass index, C-reactive protein, fasting plasma glucose, thyroid stimulating hormone, presence of microalbuminuria, history of renal calculi, history of extracorporeal shockwave lithotripsy, number and location of the stones (odds ratio 1.24, 95% confidence interval 1.02-1.52). The same was not observed for individuals with a cumulative stone size ≥ 20 mm. In kidney stone formers with a cumulative stone size up to 20 mm, estimated glomerular filtration rate linearly declines with increasing cumulative stone size. Additionally, cumulative stone size is an independent predictor of chronic kidney disease in this group of patients. © 2014 The Japanese Urological Association.
Schlosser, O; Huyard, A; Rybacki, D; Do Quang, Z
2012-06-01
Microbial quality of air inside vehicle cabs is a major occupational health risk management issue in composting facilities. Large differences and discrepancies in protection factors between vehicles and between biological agents have been reported. This study aimed at estimating the mean protection efficiency of the vehicle cab environment against bioaerosols with higher precision. In-cab measurement results were also analysed to ascertain whether or not these protection systems reduce workers' exposure to tolerable levels. Five front-end loaders, one mobile mixer and two agricultural tractors pulling windrow turners were investigated. Four vehicles were fitted with a pressurisation and high efficiency particulate air (HEPA) filtration system. The four others were only equipped with pleated paper filter without pressurisation. Bacteria, fungi and endotoxins were measured in 72 pairs of air samples, simultaneously collected inside the cab and on the outside of the cab with a CIP 10-M sampler. A front-end loader, purchased a few weeks previously, fitted with a pressurisation and high efficiency particulate air (HEPA) filtration system, and with a clean cab, exhibited a mean protection efficiency of between 99.47% CI 95% [98.58-99.97%] and 99.91% [99.78-99.98%] depending on the biological agent. It is likely that the lower protection efficiency demonstrated in other vehicles was caused by penetration through the only moderately efficient filters, by the absence of pressurisation, by leakage in the filter-sealing system, and by re-suspension of particles which accumulated in dirty cabs. Mean protection efficiency in regards to bacteria and endotoxins ranged between 92.64% [81.87-97.89%] and 98.61% [97.41-99.38%], and between 92.68% [88.11-96.08%] and 98.43% [97.44-99.22%], respectively. The mean protection efficiency was the lowest when confronted with fungal spores, from 59.76% [4.19-90.75%] to 94.71% [91.07-97.37%]. The probability that in-cab exposure to fungi exceeded the benchmark value for short-term respiratory effects suggests that front-end loaders and mobile mixers in composting facilities should be fitted with a pressurisation and HEPA filtration system, regardless of whether or not the facility is indoors or outdoors. Regarding the tractors, exposure inside the cabs was not significantly reduced. However, in this study, there was a less than 0.01% risk of exceeding the bench mark value associated with fungi related short-term respiratory effects during an 1-h per day windrow turning operation. Pressurisation and a HEPA filtration system can provide safe working conditions inside loaders and mobile mixer with regard to airborne bacteria, fungi and endotoxins in composting facilities. However, regular thorough cleaning of the vehicle cab, as well as overalls and shoes cleaning, and mitigation of leakage in the filter-sealing system are necessary to achieve high levels of protection efficiency. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Jing; Tronville, Paolo
2014-06-01
The filtration of airborne nanoparticles is an important control technique as the environmental, health, and safety impacts of nanomaterials grow. A review of the literature shows that significant progress has been made on airborne nanoparticle filtration in the academic field in the recent years. We summarize the filtration mechanisms of fibrous and membrane filters; the air flow resistance and filter media figure of merit are discussed. Our review focuses on the air filtration test methods and instrumentation necessary to implement them; recent experimental studies are summarized accordingly. Two methods using monodisperse and polydisperse challenging aerosols, respectively, are discussed in detail. Our survey shows that the commercial instruments are already available for generating a large amount of nanoparticles, sizing, and quantifying them accurately. The commercial self-contained filter test systems provide the possibility of measurement for particles down to 15 nm. Current international standards dealing with efficiency test for filters and filter media focus on measurement of the minimum efficiency at the most penetrating particle size. The available knowledge and instruments provide a solid base for development of test methods to determine the effectiveness of filtration media against airborne nanoparticles down to single-digit nanometer range.
Modeling of submicrometer aerosol penetration through sintered granular membrane filters.
Marre, Sonia; Palmeri, John; Larbot, André; Bertrand, Marielle
2004-06-01
We present a deep-bed aerosol filtration model that can be used to estimate the efficiency of sintered granular membrane filters in the region of the most penetrating particle size. In this region the capture of submicrometer aerosols, much smaller than the filter pore size, takes place mainly via Brownian diffusion and direct interception acting in synergy. By modeling the disordered sintered grain packing of such filters as a simple cubic lattice, and mapping the corresponding 3D connected pore volume onto a discrete cylindrical pore network, the efficiency of a granular filter can be estimated, using new analytical results for the efficiency of cylindrical pores. This model for aerosol penetration in sintered granular filters includes flow slip and the kinetics of particle capture by the pore surface. With a unique choice for two parameters, namely the structural tortuosity and effective kinetic coefficient of particle adsorption, this semiempirical model can account for the experimental efficiency of a new class of "high-efficiency particulate air" ceramic membrane filters as a function of particle size over a wide range of filter thickness and texture (pore size and porosity) and operating conditions (face velocity).
Estimation of Glomerular Filtration Rate from Plasma Clearance of 51-Chromium Edetic Acid
Chantler, C.; Barratt, T. M.
1972-01-01
The glomerular filtration rate was estimated by a single compartment analysis of the rate of fall of plasma concentration of 51-chromium edetic acid after a single intravenous injection. This slope clearance consistently overestimated the simultaneously determined standard urinary clearance, but could be used to predict the latter with an accuracy of ±9% (95% confidence limits). The coefficient of variation of replicate estimates of the slope clearance in the same individual was 3·9%; thus two estimates of glomerular filtration rate by this technique which differ by 11% have a 95% probability of reflecting a genuine difference. The method requires an intravenous injection and blood samples at 2 and 4 hours; urine samples are not required. It is simple, safe, and precise, and is applicable to children. PMID:4625784
Fadrowski, Jeffrey J.; Pierce, Christopher B.; Cole, Stephen R.; Moxey-Mims, Marva; Warady, Bradley A.; Furth, Susan L.
2008-01-01
Background and objectives: The level of glomerular filtration rate at which hemoglobin declines in chronic kidney disease is poorly described in the pediatric population. Design, setting, participants, & measurements: This cross-sectional study of North American children with chronic kidney disease examined the association of glomerular filtration rate, determined by the plasma disappearance of iohexol, and hemoglobin concentration. Results: Of the 340 patients studied, the mean age was 11 ± 4 yr, the mean glomerular filtration rate was 42 ± 14 ml/min per 1.73 m2, and the mean hemoglobin was 12.5 ± 1.5. Below a glomerular filtration rate of 43, the hemoglobin declined by 0.3 g/dl (95% confidence interval −0.2 to −0.5) for every 5-ml/min per 1.73 m2 decrease in glomerular filtration rate. Above a glomerular filtration rate of 43 ml/min per 1.73 m2, the hemoglobin showed a nonsignificant decline of 0.1 g/dl for every 5-ml/min per 1.73 m2 decrease in glomerular filtration rate. Conclusions: In pediatric patients with chronic kidney disease, hemoglobin declines as an iohexol-determined glomerular filtration rate decreases below 43 ml/min per 1.73 m2. Because serum creatinine–based estimated glomerular filtration rates may overestimate measured glomerular filtration rate in this population, clinicians need to be mindful of the potential for hemoglobin decline and anemia even at early stages of chronic kidney disease, as determined by current Schwartz formula estimates. Future longitudinal analyses will further characterize the relationship between glomerular filtration rate and hemoglobin, including elucidation of reasons for the heterogeneity of this association among individuals. PMID:18235140
NASA Astrophysics Data System (ADS)
Wang, Zhe; Pan, Zhijuan
2015-11-01
Hierarchical structured nano-sized/porous poly(lactic acid) (PLA-N/PLA-P) composite fibrous membranes with excellent air filtration performance were prepared via an electrospinning technique. Firstly, PLA-P fibers with different morphology were fabricated by varying the relative humidity, and the nanopores on fiber surface played a key role in improving the specific surface area and filtration performance of the resultant membranes. Secondly, hierarchical structure of PLA-N/PLA-P interlaced structured membranes and PLA-N/PLA-P double-layer structured membranes with different mass ratios for further enhanced air filtration performance were also successfully prepared by combining PLA-N fibers with PLA-P fibers. Filtration tests by measuring the penetration of sodium chloride (NaCl) aerosol particles with a 260 nm mass median diameter revealed that a moderate mass ratio of PLA-P fibers and PLA-N fibers contributed to improving the filtration performance of the hierarchical structured PLA-N/PLA-P composite membrane, and the double-layer structured PLA-N/PLA-P membrane possessed a higher filtration efficiency and quality factor than that of an interlaced structured PLA-N/PLA-P membrane with the same mass ratio. The as-prepared PLA-N/PLA-P double-layer structured membrane with a mass ratio of 1/5 showed a high filtration efficiency (99.999%) and a relatively low pressure drop (93.3 Pa) at the face velocity of 5.3 cm/s.
de Freitas, Normanda L; Gonçalves, José A S; Innocentini, Murilo D M; Coury, José R
2006-08-25
The performance of double-layered ceramic filters for aerosol filtration at high temperatures was evaluated in this work. The filtering structure was composed of two layers: a thin granular membrane deposited on a reticulate ceramic support of high porosity. The goal was to minimize the high pressure drop inherent of granular structures, without decreasing their high collection efficiency for small particles. The reticulate support was developed using the technique of ceramic replication of polyurethane foam substrates of 45 and 75 pores per inch (ppi). The filtering membrane was prepared by depositing a thin layer of granular alumina-clay paste on one face of the support. Filters had their permeability and fractional collection efficiency analyzed for filtration of an airborne suspension of phosphatic rock in temperatures ranging from ambient to 700 degrees C. Results revealed that collection efficiency decreased with gas temperature and was enhanced with filtration time. Also, the support layer influenced the collection efficiency: the 75 ppi support was more effective than the 45 ppi. Particle collection efficiency dropped considerably for particles below 2 microm in diameter. The maximum collection occurred for particle diameters of approximately 3 microm, and decreased again for diameters between 4 and 8 microm. Such trend was successfully represented by the proposed correlation, which is based on the classical mechanisms acting on particle collection. Inertial impaction seems to be the predominant collection mechanism, with particle bouncing/re-entrainment acting as detachment mechanisms.
Lam, Christopher O; Finlay, W H
2009-10-01
Fiber aerosols tend to align parallel to surrounding fluid streamlines in shear flows, making their filtration more difficult. However, previous research indicates that composite particles made from cromoglycic acid fibers coated with small nanoscaled magnetite particles can align with an applied magnetic field. The present research explored the effect of magnetically aligning these fibers to increase their filtration. Nylon net filters were challenged with the aerosol fibers, and efficiency tests were performed with and without a magnetic field applied perpendicular to the flow direction. We investigated the effects of varying face velocities, the amount of magnetite material on the aerosol particles, and magnetic field strengths. Findings from the experiments, matched by supporting single-fiber theories, showed significant efficiency increases at the low face velocity of 1.5 cm s(-1) at all magnetite compositions, with efficiencies more than doubling due to magnetic field alignment in certain cases. At a higher face velocity of 5.12 cm s(-1), filtration efficiencies were less affected by the magnetic field alignment being, at most, 43% higher for magnetite weight compositions up to 30%, while at a face velocity of 10.23 cm s(-1) alignment effects were insignificant. In most cases, efficiencies became independent of magnetic field strength above 50 mT, suggesting full alignment of the fibers. The present data suggest that fiber alignment in a magnetic field may warrant applications in the filtration and detection of fibers, such as asbestos.
Gong, Jian; Viswanathan, Sandeep; Rothamer, David A; Foster, David E; Rutland, Christopher J
2017-10-03
Motivated by high filtration efficiency (mass- and number-based) and low pressure drop requirements for gasoline particulate filters (GPFs), a previously developed heterogeneous multiscale filtration (HMF) model is extended to simulate dynamic filtration characteristics of GPFs. This dynamic HMF model is based on a probability density function (PDF) description of the pore size distribution and classical filtration theory. The microstructure of the porous substrate in a GPF is resolved and included in the model. Fundamental particulate filtration experiments were conducted using an exhaust filtration analysis (EFA) system for model validation. The particulate in the filtration experiments was sampled from a spark-ignition direct-injection (SIDI) gasoline engine. With the dynamic HMF model, evolution of the microscopic characteristics of the substrate (pore size distribution, porosity, permeability, and deposited particulate inside the porous substrate) during filtration can be probed. Also, predicted macroscopic filtration characteristics including particle number concentration and normalized pressure drop show good agreement with the experimental data. The resulting dynamic HMF model can be used to study the dynamic particulate filtration process in GPFs with distinct microstructures, serving as a powerful tool for GPF design and optimization.
Higaki, Shogo; Hirota, Masahiro
2012-01-01
Rainwater was contaminated by a large release of radionuclides into the environment during the Fukushima Daiichi nuclear disaster. It became a matter of concern for Japan when several water purification plants detected 131I contamination in the drinking water. In the present study, the decontamination efficiency of two easily obtainable commercial water purifiers were examined for rainwater contaminated with 131I, 134Cs and 137Cs. The water purifiers removed 94.2–97.8% of the 131I and 84.2–91.5% of the 134Cs and 137Cs after one filtration. Seven filtrations removed 98.2–99.6% of the 131I and over 98.0% of the 134Cs and 137Cs. From a practical perspective, over the fourth filtrations were not needed because of no significant improvements after the third filtration. PMID:22615935
Stabili, Loredana; Licciano, Margherita; Gravina, Maria Flavia; Giangrande, Adriana
2016-12-15
We investigated and compared, by laboratory experiments, the filter-feeding activity on bacteria by the solitary ascidian Styela plicata and the colonial ascidian Polyandrocarpa zorritensis. Clearance rates and retention efficiencies were estimated by using, as only food source, the bacterial species Vibrio alginolyticus selected on account of its importance in aquaculture pathogenicity. The Cmax was 1.4±0.17Lh -1 g -1 DW for S. plicata and 1.745Lh -1 g -1 DW for P. zorritensis. The highest retention efficiency was 41% corresponding to a removed bacterial biomass of 16.34+1.71 μgCL -1 g -1 DW for P. zorritensis and 81% corresponding to a bacterial biomass of 32.28+2.15 μgCL -1 g -1 DW for S. plicata. Styela plicata resulted higher efficient than P. zorritensis in removing V. alginolyticus from seawater in experimental tanks, thus representing a more suitable biofilter to restore the quality of microbiologically contaminated waters including those where aquaculture is practiced. Present laboratory experiments represent the first contribution to the comparison of the filtration activity of the two ascidians, as well as to characterize the filtration process on bacterioplankton and pone the basis for future field works aimed to restore bacteriological polluted seawater. Copyright © 2016 Elsevier B.V. All rights reserved.
Fu, Lijun; Li, Dong; Wu, Chengji; Zheng, Tianling
2012-06-04
We studied the algicidal mechanism of extracellular substances of algicidal bacteria strain BS03 (Microbulbifer sp.) on photosynthetic characteristics, antioxident enzyme system and cysteine-dependent aspartate specific protease-3 (Caspase-3) of Alexandrium tamarense. We tested photosynthetic pigments, chlorophyll fluorescence efficiency, antioxidant systems and caspase-3 activity in the algae cells treated with 0.5%, 1.0% , 1.5% and 2.0% BS03 cell-free filtrate after 12, 24, 36 and 48 h. (1) The chlorophyll-a and chlorophyll fluorescence efficiency Fv/Fm decreased with the increase of BS03 cell-free filtrate and treatment time. Carotenoids contents of A. tamarense cells treated with low BS03 (0.5% and 1.0%) cell-free filtrate were higher than the control. (2) Antioxident enzyme activities varied as treatment time and concentration. Malodialdehyde (MDA) contents increased significantly with BS03 cell-free filtrate treatment. (3) Caspase-3 protease activities of algal cells increased by BS03 cell-free filtrate. BS03 inhibited the photosynthesis whereas enhanced the lipid peroxidation of the cellular membrane of Alexandrium tamarense, indicating its algicidal activity.
Moynihan, M; Petersen, I
1981-01-01
The use of ELISA to estimate poliovirus antigen concentration has permitted an evaluation of the methodology used in vaccine production and allowed exploration of less wasteful filtration-techniques. The replacement of Seitz-EKS-1B filtration with either Seitz-Supra-EKS or Pall-filtration in the preparation of the vaccine could make a large saving in the total antigen yield, but the results in the safety test excluded their possible use in our process as it stands at the moment.
ERIC Educational Resources Information Center
Lin, Jin-Ding; Lin, Lan-Ping; Hsieh, Molly; Lin, Pei-Ying
2010-01-01
The present study aimed to describe the kidney function profile--serum creatinine and estimated glomerular filtration rate (eGFR), and to examine the relationships of predisposing factors to abnormal serum creatinine in people with intellectual disabilities (ID). Data were collected by a cross-sectional study of 827 aged 15-18 years adolescents…
Qian, Fuping; Wang, Haigang
2010-04-15
The gas-solid two-phase flows in the plain wave fabric filter were simulated by computational fluid dynamics (CFD) technology, and the warps and wefts of the fabric filter were made of filaments with different dimensions. The numerical solutions were carried out using commercial computational fluid dynamics (CFD) code Fluent 6.1. The filtration performances of the plain wave fabric filter with different geometry parameters and operating condition, including the horizontal distance, the vertical distance and the face velocity were calculated. The effects of geometry parameters and operating condition on filtration efficiency and pressure drop were studied using response surface methodology (RSM) by means of the statistical software (Minitab V14), and two second-order polynomial models were obtained with regard to the effect of the three factors as stated above. Moreover, the models were modified by dismissing the insignificant terms. The results show that the horizontal distance, vertical distance and the face velocity all play an important role in influencing the filtration efficiency and pressure drop of the plane wave fabric filters. The horizontal distance of 3.8 times the fiber diameter, the vertical distance of 4.0 times the fiber diameter and Reynolds number of 0.98 are found to be the optimal conditions to achieve the highest filtration efficiency at the same face velocity, while maintaining an acceptable pressure drop. 2009 Elsevier B.V. All rights reserved.
Jacobs, Anne; Benraad, Carolien; Wetzels, Jack; Rikkert, Marcel Olde; Kramers, Cornelis
2017-06-01
The risk of incorrect medication dosing is high in frail older people. Therefore, accurate assessment of the glomerular filtration rate is important. The objective of this study was to compare the estimated glomerular filtration rate using creatinine- and cystatin C-based formulae, the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, in frail older people. We hypothesized that frailty determines the difference between the creatinine- and cystatin C-based formulae. The mean difference between CKD-EPI creatinine and cystatin C was determined using (cross-sectional) data of 55 patients (mean age 73 years) admitted to a psychiatric ward for older adults. The level of agreement of these estimations was assessed by a Bland-Altman analysis. In all patients, the Rockwood's Frailty Index was derived and correlated with the mean difference between CKD-EPI creatinine and cystatin C. The mean difference between CKD-EPI creatinine (mean 71.2 mL/min/1.73 m 2 ) and CKD-EPI cystatin C (mean 57.6 mL/min/1.73 m 2 ) was 13.6 mL/min/1.73 m 2 (p < 0.0001). The two standard deviation limit in the Bland-Altman plot was large (43.2 mL/min/1.73 m 2 ), which represents a low level of agreement. The Frailty Index did not correlate with the mean difference between the creatinine- and cystatin C-based glomerular filtration rate (Pearson correlation coefficient 0.182, p = 0.184). There was a significant gap between a creatinine- and cystatin C-based estimation of glomerular filtration rate, irrespective of frailty. The range of differences between the commonly used estimated glomerular filtration rate formulae might result in clinically relevant differences in drug prescription and differences in chronic kidney disease staging.
The expected result of this research is a new nanostructured system for the treatment and remediation of aqueous and gaseous environments with improved efficiency over current filtration technologies. The multiple functions that these chitosan membranes will serve (removal,...
Riverbank filtration has been shown to be effective at removing viable Cryptosporidium parvum oocysts and, therefore, drinking water systems that employ riverbank filtration may receive additional treatment credits beyond that which they can obtain using traditional engineering a...
RIVERBANK FILTRATION AS A PRETREATMENT FOR NANOFILTRATION MEMBRANES
The loss of membrane efficiency due to fouling is one of the main impediments to the development of membrane processes for use in drinking water treatment. Surface waters, in general, have a greater proclivity towards fouling as compared to groundwaters. Riverbank filtration ch...
RIVERBANK FILTRATION AS A PRETREATMENT FOR NANOFILTRATION MEMBRANES
The loss of membrane efficiency due to fouling is one of the main impediments to the development of membrane processes for use in drinking water treatment. Surface waters, in general, have a greater proclivity towards fouling as compared to groundwaters. Riverbank filtration chan...
Yossepowitch, Ofer; Eggener, Scott E; Serio, Angel; Huang, William C; Snyder, Mark E; Vickers, Andrew J; Russo, Paul
2006-10-01
The emergence of laparoscopic nephron sparing surgery has rekindled interest in the impact of warm renal ischemia on renal function. To provide data with which warm renal ischemia can be compared we analyzed short-term and long-term changes in the glomerular filtration rate after temporary cold renal ischemia. In patients undergoing open nephron sparing surgery the estimated glomerular filtration rate was assessed preoperatively, early in the postoperative hospital stay, and 1 and 12 months after surgery using the abbreviated Modification of Diet in Renal Disease Study equation. We separately analyzed 70 patients with a solitary kidney and 592 with 2 functioning kidneys. The end point was the percent change from the baseline glomerular filtration rate. A linear regression model was used to test the association between the glomerular filtration rate change, and ischemia time, patient age, tumor size, estimated blood loss and intraoperative fluid administration. Median cold ischemia time was 31 minutes in patients with a solitary kidney and 35 minutes in those with 2 kidneys. Compared to patients with 2 kidneys those with a solitary kidney had a significantly lower preoperative estimated glomerular filtration rate (p < 0.001), which decreased a median of 30% during the early postoperative period, and 15% and 32% 1 and 12 months after surgery, respectively. In patients with 2 kidneys the corresponding glomerular filtration rate decreases were 16%, 13% and 14%, respectively. On multivariate analyses in each group cold ischemia duration and intraoperative blood loss were significantly associated with early glomerular filtration rate changes. However, 12 months after surgery age was the only independent predictor of a glomerular filtration rate decrease in patients with 2 kidneys. Cold renal ischemia during nephron sparing surgery is a significant determinant of the short-term postoperative glomerular filtration rate. Longer clamping time is particularly detrimental in patients with a solitary kidney but it does not appear to influence long-term renal function. Patients of advanced age may be less likely to recover from acute ischemic renal injury.
GFR Estimation: From Physiology to Public Health
Levey, Andrew S.; Inker, Lesley A.; Coresh, Josef
2014-01-01
Estimating glomerular filtration rate (GFR) is essential for clinical practice, research, and public health. Appropriate interpretation of estimated GFR (eGFR) requires understanding the principles of physiology, laboratory medicine, epidemiology and biostatistics used in the development and validation of GFR estimating equations. Equations developed in diverse populations are less biased at higher GFR than equations developed in CKD populations and are more appropriate for general use. Equations that include multiple endogenous filtration markers are more precise than equations including a single filtration marker. The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations are the most accurate GFR estimating equations that have been evaluated in large, diverse populations and are applicable for general clinical use. The 2009 CKD-EPI creatinine equation is more accurate in estimating GFR and prognosis than the 2006 Modification of Diet in Renal Disease (MDRD) Study equation and provides lower estimates of prevalence of decreased eGFR. It is useful as a “first” test for decreased eGFR and should replace the MDRD Study equation for routine reporting of serum creatinine–based eGFR by clinical laboratories. The 2012 CKD-EPI cystatin C equation is as accurate as the 2009 CKD-EPI creatinine equation in estimating eGFR, does not require specification of race, and may be more accurate in patients with decreased muscle mass. The 2012 CKD-EPI creatinine–cystatin C equation is more accurate than the 2009 CKD-EPI creatinine and 2012 CKD-EPI cystatin C equations and is useful as a confirmatory test for decreased eGFR as determined by an equation based on serum creatinine. Further improvement in GFR estimating equations will require development in more broadly representative populations, including diverse racial and ethnic groups, use of multiple filtration markers, and evaluation using statistical techniques to compare eGFR to “true GFR”. PMID:24485147
Kim, Juyoung; Chan Hong, Seung; Bae, Gwi Nam; Jung, Jae Hee
2017-10-17
Filtration technology has been widely studied due to concerns about exposure to airborne dust, including metal oxide nanoparticles, which cause serious health problems. The aim of these studies has been to develop mechanisms for the continuous and efficient removal of metal oxide dusts. In this study, we introduce a novel air filtration system based on the magnetic attraction force. The filtration system is composed of a magnetic nanoparticle (MNP)-decorated nanofiber (MNP-NF) filter. Using a simple electrospinning system, we fabricated continuous and smooth electrospun nanofibers with evenly distributed Fe 3 O 4 MNPs. Our electrospun MNP-NF filter exhibited high particle collection efficiency (∼97% at 300 nm particle size) compared to the control filter (w/o MNPs, ∼ 68%), with a ∼ 64% lower pressure drop (∼17 Pa) than the control filter (∼27 Pa). Finally, the filter quality factors of the MNP-NF filter were 4.7 and 11.9 times larger than those of the control filter and the conventional high-efficiency particulate air filters (>99% and ∼269 Pa), respectively. Furthermore, we successfully performed a field test of our MNP-NF filter using dust from a subway station tunnel. This work suggests that our novel MNP-NF filter can be used to facilitate effective protection against hazardous metal oxide dust in real environments.
Rodriguez-Chiang, Lourdes; Vanhatalo, Kari; Llorca, Jordi; Dahl, Olli
2017-07-01
Chemical pulp mills have a need to diversify their end-product portfolio due to the current changing bio-economy. In this study, the methane potential of brown, oxygen delignified and bleached pulp were evaluated in order to assess the potential of converting traditional fibers; as well as microcrystalline cellulose and filtrates; to energy. Results showed that high yields (380mL CH 4 /gVS) were achieved with bleached fibers which correlates with the lower presence of lignin. Filtrates from the hydrolysis process on the other hand, had the lowest yields (253mL CH 4 /gVS) due to the high amount of acid and lignin compounds that cause inhibition. Overall, substrates had a biodegradability above 50% which demonstrates that they can be subjected to efficient anaerobic digestion. An energy and cost estimation showed that the energy produced can be translated into a significant profit and that methane production can be a promising new alternative option for chemical pulp mills. Copyright © 2017 Elsevier Ltd. All rights reserved.
Improving indoor air quality through botanical air filtration in energy efficient residences
NASA Astrophysics Data System (ADS)
Newkirk, Daniel W.
According to the U.S. EPA, the average American spends 90% of their time indoors where pollutants are two to five times more prevalent than outside. The consequences of these pollutants are estimated to cost the U.S. 125 billion dollars in lost health and productivity. Background literature suggests botanical air filtration may be able to solve this problem by leveraging the natural ability of plants to purify indoor air. By improving indoor air quality, energy consumption can also be reduced by bringing in less outside air to dilute contaminants within the space. A botanical air filter, called the Biowall, was designed and grown aeroponically in a sealed environmental chamber. Precise measurements of air temperature, air humidity, air quality and energy consumption were made under various lighting levels, plant species and watering strategies to optimize its performance. It was found to reduce indoor air pollutants 60 percent and has the potential to reduce heating and cooling energy consumption by 20 to 30 percent.
Effects of oil on the feeding mechanism of the bowhead whale. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braithwaite, L.F.
1983-06-10
Research was designed to determine the effect of crude oil on the filtration efficiency of bowhead whale (Balaena mysticetus) baleen. An experiment apparatus was constructed with temperature-controlled, circulating sea water moving through a chamber containing mounted baleen plates. All circulating water of the apparatus flowed over and through the hair-fringed stratum of the baleen plates. Efficiency of filtration of living plankters was measured and compared for various kinds and levels of petroleum fouling. The filtering efficiency of the baleen plates decreased when the plates were fouled with Prudhoe Bay crude oil.
NASA Astrophysics Data System (ADS)
Manzo, Gabriel
Coalescing filters are used to remove small liquid droplets from air streams. They have numerous industrial applications including dehumidification, cabin air filtration, compressed air filtration, metal working, CCV, and agriculture. In compressed air systems, oils used for lubrication of compressor parts can aerosolize into the main air stream causing potential contamination concerns for downstream applications. In many systems, humid air can present problems to sensitive equipment and sensors. As the humid air cools, small water drops condense and can disrupt components that need to be kept dry. Fibrous nonwoven filter media are commonly used to coalesce small drops into larger drops for easier removal. The coalescing performance of a medium is dependent upon several parameters including permeability, porosity, and wettability. In many coalescing filters, glass fibers are used. In this work, the properties of steel fiber media are measured to see how these properties compare to glass fiber media. Steel fiber media has different permeability, porosity and wettability to oil and water than fiber glass media. These differences can impact coalescence performance. The impact of these differences in properties on coalescence filtration performance was evaluated in a coalescence test apparatus. The overall coalescence performance of the steel and glass nonwoven fiber media are compared using a filtration efficiency and filtration index. In many cases, the stainless steel media performed comparably to fiber glass media with efficiencies near 90%. Since stainless steel media had lower pressure drops than fiber glass media, its filtration index values were significantly higher. Broader impact of this work is the use of stainless steel fiber media as an alternative to fiber glass media in applications where aerosol filtration is needed to protect the environment or sensitive equipment and sensors.
Lane, Brian R; Demirjian, Sevag; Weight, Christopher J; Larson, Benjamin T; Poggio, Emilio D; Campbell, Steven C
2010-03-01
Accurate renal function determination before and after nephrectomy is essential for proper prevention and management of chronic kidney disease due to nephron loss and ischemic injury. We compared the estimated glomerular filtration rate using several serum creatinine based formulas against the measured rate based on (125)I-iothalamate clearance to determine which most accurately reflects the rate in this setting. Of 7,611 patients treated at our institution since 1975 the measured glomerular filtration rate was selectively determined before and after nephrectomy in 268 and 157, respectively. Performance of the Cockcroft-Gault, Modification of Diet in Renal Disease Study, re-expressed Modification of Diet in Renal Disease Study and Chronic Kidney Disease-Epidemiology Study equations, each of which estimates the glomerular filtration rate, were determined using serum creatinine, age, gender, weight and body surface area. The performance of serum creatinine, reciprocal serum creatinine and the 4 formulas was compared with the measured rate using Pearson's correlation, Lin's concordance coefficient and residual plots. Median serum creatinine was 1.4 mg/dl and the median measured glomerular filtration rate was 50 ml per minute per 1.73 m(2). The correlation between serum creatinine and the measured rate was poor (-0.66) compared with that of reciprocal serum creatinine (0.78) and the 4 equations (0.82 to 0.86). The Chronic Kidney Disease-Epidemiology Study equation performed with greatest precision and accuracy, and least bias of all equations. Stage 3 or greater chronic kidney disease ((125)I-iothalamate glomerular filtration rate 60 ml per minute per 1.73 m(2) or less) was present in 44% of patients with normal serum creatinine (1.4 mg/dl or less) postoperatively. Such missed diagnoses of chronic kidney disease decreased 42% using the Chronic Kidney Disease-Epidemiology Study equation. Glomerular filtration rate estimation equations outperform serum creatinine and better identify patients with perinephrectomy compromised renal function. The newly developed, serum creatinine based, Chronic Kidney Disease-Epidemiology Study equation has sufficient accuracy to render direct glomerular filtration rate measurement unnecessary before and after nephrectomy for cause in most circumstances. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ottney, T.C.
Filtration systems that are incorrectly selected, installed and maintained can cause excessive particulates in occupied spaces. This article describes how to identify and correct problems. Particulate matter can be removed from ventilation air at several sites within a building. These sites include: on heat exchanger surfaces; inside ductwork, ceiling tiles and diffusers; and in the air filter. The cost associated with removing these unwanted contaminants is unavoidable. However, this removal cost varies depending on where the particulates have been deposited. Not all particulates that are generated by work-related activities are transported to the filter bank by return air currents beforemore » being deposited on other surfaces. Accordingly, walls still have to be repainted at varying intervals and carpeting vacuumed. Ceiling tiles will discolor at a rate that is influenced by their texture, the air outlet velocity, the amount of dirt in the ventilation air and how much contaminant is being generated in the room. It is estimated that 15% of ventilation air escapes the air filtration process. This leakage results in higher utility, janitorial and redecorating costs as well as contributing to employee absenteeism. When building management does not prevent it, air-conditioning coils and ductwork become an unintended part of the building's air filtration system. In time, this is much more expensive both in energy and cleaning costs than the steps available to keep them clean. Good particulate control can lower the total cost of building operation. However, a building operator may not have to upgrade to a higher efficiency filter to achieve higher system efficiency. Simply eliminating the source of leaks and better management of the existing filters may be all that is necessary.« less
Paramonova, Ekaterina; Zerfoss, Erica L.; Logan, Bruce E.
2006-01-01
Point-of-use filters containing granular activated carbon (GAC) are an effective method for removing certain chemicals from water, but their ability to remove bacteria and viruses has been relatively untested. Collision efficiencies (α) were determined using clean-bed filtration theory for two bacteria (Raoutella terrigena 33257 and Escherichia coli 25922), a bacteriophage (MS2), and latex microspheres for four GAC samples. These GAC samples had particle size distributions that were bimodal, but only a single particle diameter can be used in the filtration equation. Therefore, consistent with previous reports, we used a particle diameter based on the smallest diameter of the particles (derived from the projected areas of 10% of the smallest particles). The bacterial collision efficiencies calculated using the filtration model were high (0.8 ≤ α ≤ 4.9), indicating that GAC was an effective capture material. Collision efficiencies greater than unity reflect an underestimation of the collision frequency, likely as a result of particle roughness and wide GAC size distributions. The collision efficiencies for microspheres (0.7 ≤ α ≤ 3.5) were similar to those obtained for bacteria, suggesting that the microspheres were a reasonable surrogate for the bacteria. The bacteriophage collision efficiencies ranged from ≥0.2 to ≤0.4. The predicted levels of removal for 1-cm-thick carbon beds ranged from 0.8 to 3 log for the bacteria and from 0.3 to 1.0 log for the phage. These tests demonstrated that GAC can be an effective material for removal of bacteria and phage and that GAC particle size is a more important factor than relative stickiness for effective particle removal. PMID:16885264
Muntner, Paul; Vupputuri, Suma; Coresh, Josef; Uribarri, Jaime; Fox, Caroline S.
2011-01-01
Elevated serum cystatin C may represent an early stage of kidney disease. It is unclear whether metabolic abnormalities typically seen in advanced chronic kidney disease are present in adults with estimated glomerular filtration rate ≥60 ml/min/1.73m2 and elevated cystatin C. Participants of the Third National Health and Nutrition Examination Survey (n=6722) were categorized into three groups: estimated glomerular filtration rate ≥ 60 ml/min/1.73m2 and cystatin C <1.09 mg/L (normal cystatin C); estimated glomerular filtration rate ≥60 ml/min/1.73m2 and cystatin C ≥1.09 mg/L (elevated cystatin C); and estimated glomerular filtration rate of 15-59 ml/min/1.73m2 (stage 3 or 4 chronic kidney disease). Among those with normal cystatin C, elevated cystatin C, and stage 3 or 4 chronic kidney disease, the age, race-ethnicity, sex standardized prevalence of serum hemoglobin <12 g/dL (<13 g/dL for men) was 4.3%, 8.2%, and 13.8%; serum uric acid ≥ 5.9 mg/dL (≥7.4 mg/dL for men) was 12.6%, 30.0%, and 45.0%; serum homocysteine ≥13 μmol/L was 12.1%, 25.1%, and 41.0%; serum phosphorus ≥3.9 mg/dL was 17.2%, 23.2%, and 25.8%; serum albumin <3.8 mg/dL was 14.5%, 20.0%, and 20.4%; plasma fibrinogen ≥352 mg/dL was 10.5%, 21.7%, and 23.2%; and C-reactive protein ≥1.0 g/dL was 7.5%, 22.5%, and 21.6% (each p-trend<0.001). Among adults with estimated glomerular filtration rate ≥60 ml/min/1.73m2, elevated serum cystatin C is associated with an increased prevalence of several metabolic abnormalities. PMID:19295502
Maqbool, Tahir; Khan, Sher Jamal; Lee, Chung-Hak
2014-11-01
Relaxation or backwashing is obligatory for effective operation of membrane module and intermittent aeration is helpful for nutrients removal. This study was performed to investigate effects of different filtration modes on membrane fouling behavior and treatment in membrane bioreactor (MBR) operated at three modes i.e., 12, 10 and 8min filtration and 3, 2, and 2min relaxation corresponding to 6, 5 and 4cycles/hour, respectively. Various parameters including trans-membrane pressure, specific cake resistance, specific oxygen uptake rate, nutrients removal and sludge dewaterability were examined to optimize the filtration mode. TMP profiles showed that MBR(8+2) with 8min filtration and 2min relaxation reduced the fouling rate and depicted long filtration time in MBR treating synthetic wastewater. MBR(12+3) was more efficient in organic and nutrients removal while denitrification rate was high in MBR(8+2). Copyright © 2014 Elsevier Ltd. All rights reserved.
Qiu, Ling; Guo, Xiuzhi; Zhu, Yan; Shou, Weilin; Gong, Mengchun; Zhang, Lin; Han, Huijuan; Quan, Guoqiang; Xu, Tao; Li, Hang; Li, Xuewang
2013-01-01
To investigate the impact of serum creatinine measurement on the applicability of glomerular filtration rate (GFR) evaluation equations. 99mTc-DTPA plasma clearance rate was used as GFR reference (rGFR) in patients with chronic kidney disease (CKD). Serum creatinine was measureded using enzymatic or picric acid creatinine reagent. The GFR of the patients were estimated using the Cockcroft-Gault equation corrected for body surface area, simplified Modification of Diet in Renal Disease (MDRD) equation, simplified MDRD equation corrected to isotopes dilution mass spectrometry, the CKD epidemiology collaborative research equation, and two Chinese simplified MDRD equations. Significant differences in the eGFR results estimated through enzymatic and picric acid methods were observed for the same evaluation equation. The intraclass correlation coefficient (ICC) of eGFR when the creatinine was measured by the picric acid method was significantly lower than that of the enzymatic method. The assessment accuracy of every equation using the enzymatic method to measure creatinine was significantly higher than that measured by the picric acid method when rGFR was > or = 60 mL/min/1.73m2. A significant difference was demonstrated in the same GFR evaluation equation using the picric acid and enzymatic methods. The enzymatic creatinine method was better than the picric acid method.
Samuel, Manoj P; Senthilvel, S; Tamilmani, D; Mathew, A C
2012-09-01
A horizontal flow multimedia stormwater filter was developed and tested for hydraulic efficiency and pollutant removal efficiency. Gravel, coconut (Cocos nucifera) fibre and sand were selected as the media and filled in 1:1:1 proportion. A fabric screen made up of woven sisal hemp was used to separate the media. The adsorption behaviour of coir fibre was determined in a series of column and batch studies and the corresponding isotherms were developed. The hydraulic efficiency of the filter showed a diminishing trend as the sediment level in inflow increased. The filter exhibited 100% sediment removal at lower sediment concentrations in inflow water (>6 g L(-1)). The filter could remove NO3(-), SO4(2-) and total solids (TS) effectively. Removal percentages of Mg(2+) and Na(+) were also found to be good. Similar results were obtained from a field evaluation study. Studies were also conducted to determine the pattern of silt and sediment deposition inside the filter body. The effects of residence time and rate of flow on removal percentages of NO3(-) and TS were also investigated out. In addition, a multiple regression equation that mathematically represents the filtration process was developed. Based on estimated annual costs and returns, all financial viability criteria (internal rate of return, net present value and benefit-cost ratio) were found favourable and affordable to farmers for investment in the developed filtration system. The model MUSIC was calibrated and validated for field conditions with respect to the developed stormwater filter.
Filter aids influence on pressure drop across a filtration system
NASA Astrophysics Data System (ADS)
Hajar, S.; Rashid, M.; Nurnadia, A.; Ammar, M. R.; Hasfalina, C. M.
2017-06-01
Filter aids is commonly used to reduce pressure drop across air filtration system as it helps to increase the efficiency of filtration of accumulated filter cake. Filtration velocity is one of the main parameters that affect the performance of filter aids material. In this study, a formulated filter aids consisting of PreKot™ and activated carbon mixture (designated as PrekotAC) was tested on PTFE filter media under various filtration velocities of 5, 6, and 8 m/min at a constant material loading of 0.2 mg/mm2. Results showed that pressure drop is highly influenced by filtration velocity where higher filtration velocity leads to a higher pressure drop across the filter cake. It was found that PrekotAC performed better in terms of reducing the pressure drop across the filter cake even at the highest filtration velocity. The diversity in different particle size distribution of non-uniform particle size in the formulated PrekotAC mixture presents a higher permeability causes a lower pressure drop across the accumulated filter cake. The finding suggests that PrekotAC is a promising filter aids material that helps reducing the pressure drop across fabric filtration system.
Koivula, Elsi; Kallioinen, Mari; Sainio, Tuomo; Antón, Enrique; Luque, Susana; Mänttäri, Mika
2013-09-01
In this study adsorption of foulants from birch and pine/eucalyptus wood hydrolysates on two polymeric adsorbents was studied aiming to reduce the membrane fouling. The effect of the pretreatment of hydrolysate on polyethersulphone membrane performance was studied in dead-end filtration experiments. Adsorption pretreatment improved significantly filtration capacity and decreased membrane fouling. Especially high-molecular weight lignin was efficiently removed. A multistep adsorption pretreatment was found to reduce the amount of adsorbent required. While large adsorbent amount was shown to increase flux in filtration, it was found also to cause significant hemicellulose losses. Copyright © 2013 Elsevier Ltd. All rights reserved.
Horwatich, Judy A.; Bannerman, Roger T.; Pearson, Robert
2011-01-01
The treatment efficiencies of two prefabricated stormwater-treatment devices were tested at a freeway site in a high-density urban part of Milwaukee, Wisconsin. One treatment device is categorized as a hydrodynamic-settling device (HSD), which removes pollutants by sedimentation and flotation. The other treatment device is categorized as a stormwater-filtration device (SFD), which removes pollutants by filtration and sedimentation. During runoff events, flow measurements were recorded and water-quality samples were collected at the inlet and outlet of each device. Efficiency-ratio and summation-of-load (SOL) calculations were used to estimate the treatment efficiency of each device. Event-mean concentrations and loads that were decreased by passing through the HSD include total suspended solids (TSS), suspended sediment (SS), total phosphorus (TP), total copper (TCu), and total zinc (TZn). The efficiency ratios for these constituents were 42, 57, 17, 33, and 23 percent, respectively. The SOL removal rates for these constituents were 25, 49, 10, 27, and 16 percent, respectively. Event-mean concentrations and loads that increased by passing through the HSD include chloride (Cl), total dissolved solids (TDS), and dissolved zinc (DZn). The efficiency ratios for these constituents were -347, -177, and 20 percent, respectively. Four constituents—dissolved phosphorus (DP), chemical oxygen demand (COD), total polycyclic aromatic hydrocarbon (PAH), and dissolved copper (DCu)—are not included in the list of computed efficiency ratio and SOL because the variability between sampled inlet and outlet pairs were not significantly different. Event-mean concentrations and loads that decreased by passing through the SFD include TSS, SS, TP, DCu, TCu, DZn, TZn, and COD. The efficiency ratios for these constituents were 59, 90, 40, 21, 66, 23, 66, and 18, respectively. The SOLs for these constituents were 50, 89, 37, 19, 60, 20, 65, and 21, respectively. Two constituents—DP and PAH—are not included in the lists of computed efficiency ratio and SOL because the variability between sampled inlet and outlet pairs were not significantly different. Similar to the HSD, the average efficiency ratios and SOLs for TDS and Cl were negative. Flow rates, high concentrations of SS, and particle-size distributions (PSD) can affect the treatment efficacies of the two devices. Flow rates equal to or greater than the design flow rate of the HSD had minimal or negative removal efficiencies for TSS and SS loads. Similar TSS removal efficiencies were observed at the SFD, but SS was consistently removed throughout the flow regime. Removal efficiencies were high for both devices when concentrations of SS and TSS approached 200 mg/L. A small number of runoff events were analyzed for PSD; the average sand content at the HSD was 33 percent and at the SFD was 71 percent. The 71-percent sand content may reflect the 90-percent removal efficiency of SS at the SFD. Particles retained at the bottom of both devices were largely sand-size or greater.
Pig manure treatment by filtration.
Kowalski, Zygmunt; Makara, Agnieszka; Matýsek, Dalibor; Hoffmann, Józef; Hoffmann, Krystyna
2013-01-01
A study of new pig manure treatment and filtration process was carried out. The advantage of the worked out technology is the method of incorporation of crystalline phase into solid organic part of manure. The obtained new solid phase of manure contains about 50% of crystalline phase forming a filtration aid that enables high effectiveness of manure filtration. The filtration rate of manure separation into solid and liquid fractions with pressure filter may achieve 1300-3000 kg/m(2)/h. The method makes it possible to maintain an overall average pollutant removal performance 90% for the chemical oxygen demand COD, > 99% for the suspended solids SS, to 47% for the total nitrogen content. The obtained results showed that the proposed technology being efficient and simple offers a possible solution to pig manure problems.
Flexographic newspaper deinking : treatment of wash filtrate effluent by membrane technology
B. Chabot; G.A. Krishnagopalan; S. Abubakr
1999-01-01
Ultrafiltration was investigated as a means to remove flexographic ink pigments from wash filtrate effluent generated from various mixtures of flexographic and offset old newspapers from deinking operations. Membrane separation efficiency was assessed from permeate flux, fouling rate, and ease of membrane regeneration (cleaning). Ultrafiltration was capable of...
The Environmental Technology Verification report discusses the technology and performance of the AFP30 air filter for dust and bioaerosol filtration manufactured by Airflow Products. The pressure drop across the filter was 62 Pa clean and 247 Pa dust loaded. The filtration effici...
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
Polyaluminium chloride as an alternative to alum for the direct filtration of drinking water.
Zarchi, Idit; Friedler, Eran; Rebhun, Menahem
2013-01-01
The efficiency of various polyaluminium chloride coagulants (PACls) was compared to the efficiency of aluminium sulfate (alum) in the coagulation-flocculation process preceding direct filtration in drinking water treatment. The comparative study consisted of two separate yet complementary series of experiments: the first series included short (5-7 h) and long (24 h) filter runs conducted at a pilot filtration plant equipped with large filter columns that simulated full-scale filters. Partially treated surface water from the Sea of Galilee, characterized by very low turbidity (-1 NTU), was used. In the second series of experiments, speciation of aluminium in situ was investigated using the ferron assay method. Results from the pilot-scale study indicate that most PACls were as or more efficient a coagulant as alum for direct filtration of surface water without requiring acid addition for pH adjustment and subsequent base addition for re-stabilizing the water. Consequently, cost analysis of the chemicals needed for the process showed that treatment with PACl would be significantly less costly than treatment with alum. The aluminium speciation experiments revealed that the performance of the coagulant is more influenced by the species present during the coagulation process than those present in the original reagents.
Enhanced diffusion on oscillating surfaces through synchronization
NASA Astrophysics Data System (ADS)
Wang, Jin; Cao, Wei; Ma, Ming; Zheng, Quanshui
2018-02-01
The diffusion of molecules and clusters under nanoscale confinement or absorbed on surfaces is the key controlling factor in dynamical processes such as transport, chemical reaction, or filtration. Enhancing diffusion could benefit these processes by increasing their transport efficiency. Using a nonlinear Langevin equation with an extensive number of simulations, we find a large enhancement in diffusion through surface oscillation. For helium confined in a narrow carbon nanotube, the diffusion enhancement is estimated to be over three orders of magnitude. A synchronization mechanism between the kinetics of the particles and the oscillating surface is revealed. Interestingly, a highly nonlinear negative correlation between diffusion coefficient and temperature is predicted based on this mechanism, and further validated by simulations. Our results provide a general and efficient method for enhancing diffusion, especially at low temperatures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sisniega, A.; Vaquero, J. J., E-mail: juanjose.vaquero@uc3m.es; Instituto de Investigación Sanitaria Gregorio Marañón, Madrid ES28007
Purpose: The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammography. However, most of these models cannot be used directly for modeling microfocus x-ray sources due to differences in inherent filtration, energy range and/or anode material. For this reason the authors propose in this work a new model for the simulation of microfocus spectra based on existing models for mammography and radiology, modifiedmore » to compensate for the effects of inherent filtration and energy range. Methods: The authors used the radiology and mammography versions of an existing empirical model [tungsten anode spectral model interpolating polynomials (TASMIP)] as the basis of the microfocus model. First, the authors estimated the inherent filtration included in the radiology model by comparing the shape of the spectra with spectra from the mammography model. Afterwards, the authors built a unified spectra dataset by combining both models and, finally, they estimated the parameters of the new version of TASMIP for microfocus sources by calibrating against experimental exposure data from a microfocus x-ray source. The model was validated by comparing estimated and experimental exposure and attenuation data for different attenuating materials and x-ray beam peak energy values, using two different x-ray tubes. Results: Inherent filtration for the radiology spectra from TASMIP was found to be equivalent to 1.68 mm Al, as compared to spectra obtained from the mammography model. To match the experimentally measured exposure data the combined dataset required to apply a negative filtration of about 0.21 mm Al and an anode roughness of 0.003 mm W. The validation of the model against real acquired data showed errors in exposure and attenuation in line with those reported for other models for radiology or mammography. Conclusions: A new version of the TASMIP model for the estimation of x-ray spectra in microfocus x-ray sources has been developed and validated experimentally. Similarly to other versions of TASMIP, the estimation of spectra is very simple, involving only the evaluation of polynomial expressions.« less
FILTRATION OF GROUND WATER SAMPLES FOR METALS ANALYSIS
The filtration of a ground water samples with 0.45 um filters for determination of 'dissolved' metals is not only inaccurate for distinguishing between dissolved and particulate phases, but if used for estimates of mobile contaminant loading in a given aquifer, may result in sign...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azhar, A.; Hamdy, M.K.
Use of ultrafiltration membrane systems in stirred cell and in thin-channel systems for immobilizing enzyme (sweet potato intrinsic and crystalline beta-amylase) in hydrolysis of sweet potato through a continuous operation mode were studied. Both the filtration rate and reducing sugars, produced as the result of enzymic hydrolysis, decreased with the filtration time. The immobilized enzymes in the thin-channel system showed a much better performance compared to that in the stirred cell system. Addition of crystalline sweet potato beta-amylase to the sweet potato increased both the filtration rate and reducing-sugars content. Alcohol fermentation of the filtrate resulted in an alcohol contentmore » of 4.2%. This represented fermentation of 95% of the sugars with an efficiency of 88%.« less
Battery-Powered Field Filtration Assembly Using an Inexpensive Mini-Compressor.
ERIC Educational Resources Information Center
Corbett, Robert G.; Quick, Thomas J.
1986-01-01
Suggests how modifications on a mini-compressor can result in a low-cost vacuum filtration system for use with suspended sediments in the field or laboratory. Explains and illustrates the changes needed to make the apparatus efficient and servicable for providing data for mass balance, geochemical exploration, and environmental studies. (ML)
Higaki, Shogo; Hirota, Masahiro
2012-01-01
Rainwater was contaminated by a large release of radionuclides into the environment during the Fukushima Daiichi nuclear disaster. It became a matter of concern for Japan when several water purification plants detected ¹³¹I contamination in the drinking water. In the present study, the decontamination efficiency of two easily obtainable commercial water purifiers were examined for rainwater contaminated with ¹³¹I, ¹³⁴Cs and ¹³⁷Cs. The water purifiers removed 94.2-97.8% of the ¹³¹I and 84.2-91.5% of the ¹³⁴Cs and ¹³⁷Cs after one filtration. Seven filtrations removed 98.2-99.6% of the ¹³¹I and over 98.0% of the ¹³⁴Cs and ¹³⁷Cs. From a practical perspective, over the fourth filtrations were not needed because of no significant improvements after the third filtration.
Test of precoat filtration technology for treatment of swimming pool water.
Christensen, Morten Lykkegaard; Klausen, Morten Møller; Christensen, Peter Vittrup
2018-02-01
The technical performance of a precoat filter was compared with that of a traditional sand filter. Particle concentration and size distribution were measured before and after the filtration of swimming pool water. Both the sand and precoat filters could reduce the particle concentration in the effluent. However, higher particle removal efficiency was generally observed for the precoat filter, especially for particles smaller than 10 μm in diameter. Adding flocculant improved the removal efficiency of the sand filter, resulting in removal efficiencies comparable to those of the precoat filter. Three powders, i.e., two types of perlite (Harbolite ® and Aquatec perlite) and cellulose fibers (Arbocel ® ), were tested for the precoat filter, but no significant difference in particle removal efficiency was observed among them. The maximum efficiency was reached within 30-40 min of filtration. The energy required for the pumps increased by approximately 35% over a period of 14 days. The energy consumption could be reduced by replacing the powder on the filter cloth. The sand filter was backwashed once a week, while the powder on the precoat filter was replaced every two weeks. Under these conditions, it was possible to reduce the water used for cleaning by 88% if the precoat filter was used instead of the sand filter.
NASA Astrophysics Data System (ADS)
Kellnerová, E.; Večeřa, Z.; Kellner, J.; Zeman, T.; Navrátil, J.
2018-03-01
The paper evaluates the filtration and sorption efficiency of selected types of military combined filters and protective filters. The testing was carried out with the use of ultra-fine aerosol containing cupric oxide nanoparticles ranging in size from 7.6 nm to 299.6 nm. The measurements of nanoparticles were carried out using a scanning mobility particle sizer before and after the passage through the filter and a developed sampling device at the level of particle number concentration approximately 750000 particles·cm-3. The basic parameters of permeability of ultra-fine aerosol passing through the tested material were evaluated, in particular particle size, efficiency of nanoparticle capture by filter, permeability coefficient and overall filtration efficiency. Results indicate that the military filter and particle filters exhibited the highest aerosol permeability especially in the nanoparticle size range between 100–200 nm, while the MOF filters had the highest permeability in the range of 200 to 300 nm. The Filter Nuclear and the Health and Safety filter had 100% nanoparticle capture efficiency and were therefore the most effective. The obtained measurement results have shown that the filtration efficiency over the entire measured range of nanoparticles was sufficient; however, it was different for particular particle sizes.
Characterization of drinking water treatment for virus risk assessment.
Teunis, P F M; Rutjes, S A; Westrell, T; de Roda Husman, A M
2009-02-01
Removal or inactivation of viruses in drinking water treatment processes can be quantified by measuring the concentrations of viruses or virus indicators in water before and after treatment. Virus reduction is then calculated from the ratio of these concentrations. Most often only the average reduction is reported. That is not sufficient when treatment efficiency must be characterized in quantitative risk assessment. We present three simple models allowing statistical analysis of series of counts before and after treatment: distribution of the ratio of concentrations, and distribution of the probability of passage for unpaired and paired water samples. Performance of these models is demonstrated for several processes (long and short term storage, coagulation/filtration, coagulation/sedimentation, slow sand filtration, membrane filtration, and ozone disinfection) using microbial indicator data from full-scale treatment processes. All three models allow estimation of the variation in (log) reduction as well as its uncertainty; the results can be easily used in risk assessment. Although they have different characteristics and are present in vastly different concentrations, different viruses and/or bacteriophages appear to show similar reductions in a particular treatment process, allowing generalization of the reduction for each process type across virus groups. The processes characterized in this paper may be used as reference for waterborne virus risk assessment, to check against location specific data, and in case no such data are available, to use as defaults.
Metal reduction at point-of-use filtration
NASA Astrophysics Data System (ADS)
Umeda, Toru; Daikoku, Shusaku; Varanasi, Rao; Tsuzuki, Shuichi
2016-03-01
We explored the metal removal efficiency of Nylon 6,6 and HDPE (High Density Polyethylene) membrane based filters, in solvents of varying degree of polarity such as Cyclohexanone and 70:30 mixture of PGME (Propylene Glycol Monomethyl Ether) and PGMEA (Propylene Glycol Monomethyl Ether), In all the solvents tested, Nylon 6,6 membrane filtration was found to be significantly more effective in removing metals than HDPE membranes, regardless of their respective membrane pore sizes. Hydrophilic interaction chromatography (HILIC) mechanism was invoked to rationalize metal removal efficiency dependence on solvent hydrophobicity.
Efficiency of different air filter types for pig facilities at laboratory scale
Wenke, Cindy; Pospiech, Janina; Reutter, Tobias; Truyen, Uwe
2017-01-01
Air filtration has been shown to be efficient in reducing pathogen burden in circulating air. We determined at laboratory scale the retention efficiency of different air filter types either composed of a prefilter (EU class G4) and a secondary fiberglass filter (EU class F9) or consisting of a filter mat (EU class M6 and F8-9). Four filter prototypes were tested for their capability to remove aerosol containing equine arteritis virus (EAV), porcine reproductive and respiratory syndrome virus (PRRSV), bovine enterovirus 1 (BEV), Actinobacillus pleuropneumoniae (APP), and Staphylococcus (S.) aureus from air. Depending on the filter prototype and utilisation, the airflow was set at 1,800 m3/h (combination of upstream prefilter and fiberglass filter) or 80 m3/h (filter mat). The pathogens were aerosolized and their concentration was determined in front of and behind the filter by culture or quantitative real-time RT-PCR. Furthermore, survival of the pathogens over time in the filter material was determined. Bacteria were most efficiently filtered with a reduction rate of up to 99.9% depending on the filter used. An approximately 98% reduction was achieved for the viruses tested. Viability or infectivity of APP or PRRSV in the filter material decreased below the detection limit after 4 h and 24 h, respectively, whereas S. aureus was still culturable after 4 weeks. Our results demonstrate that pathogens can efficiently be reduced by air filtration. Consequently, air filtration combined with other strict biosecurity measures markedly reduces the risk of introducing airborne transmitted pathogens to animal facilities. In addition, air filtration might be useful in reducing bioaerosols within a pig barn, hence improving respiratory health of pigs. PMID:29028843
Efficiency of different air filter types for pig facilities at laboratory scale.
Wenke, Cindy; Pospiech, Janina; Reutter, Tobias; Truyen, Uwe; Speck, Stephanie
2017-01-01
Air filtration has been shown to be efficient in reducing pathogen burden in circulating air. We determined at laboratory scale the retention efficiency of different air filter types either composed of a prefilter (EU class G4) and a secondary fiberglass filter (EU class F9) or consisting of a filter mat (EU class M6 and F8-9). Four filter prototypes were tested for their capability to remove aerosol containing equine arteritis virus (EAV), porcine reproductive and respiratory syndrome virus (PRRSV), bovine enterovirus 1 (BEV), Actinobacillus pleuropneumoniae (APP), and Staphylococcus (S.) aureus from air. Depending on the filter prototype and utilisation, the airflow was set at 1,800 m3/h (combination of upstream prefilter and fiberglass filter) or 80 m3/h (filter mat). The pathogens were aerosolized and their concentration was determined in front of and behind the filter by culture or quantitative real-time RT-PCR. Furthermore, survival of the pathogens over time in the filter material was determined. Bacteria were most efficiently filtered with a reduction rate of up to 99.9% depending on the filter used. An approximately 98% reduction was achieved for the viruses tested. Viability or infectivity of APP or PRRSV in the filter material decreased below the detection limit after 4 h and 24 h, respectively, whereas S. aureus was still culturable after 4 weeks. Our results demonstrate that pathogens can efficiently be reduced by air filtration. Consequently, air filtration combined with other strict biosecurity measures markedly reduces the risk of introducing airborne transmitted pathogens to animal facilities. In addition, air filtration might be useful in reducing bioaerosols within a pig barn, hence improving respiratory health of pigs.
Control of asthma triggers in indoor air with air cleaners: a modeling analysis.
Myatt, Theodore A; Minegishi, Taeko; Allen, Joseph G; Macintosh, David L
2008-08-06
Reducing exposure to environmental agents indoors shown to increase asthma symptoms or lead to asthma exacerbations is an important component of a strategy to manage asthma for individuals. Numerous investigations have demonstrated that portable air cleaning devices can reduce concentrations of asthma triggers in indoor air; however, their benefits for breathing problems have not always been reproducible. The potential exposure benefits of whole house high efficiency in-duct air cleaners for sensitive subpopulations have yet to be evaluated. We used an indoor air quality modeling system (CONTAM) developed by NIST to examine peak and time-integrated concentrations of common asthma triggers present in indoor air over a year as a function of natural ventilation, portable air cleaners, and forced air ventilation equipped with conventional and high efficiency filtration systems. Emission rates for asthma triggers were based on experimental studies published in the scientific literature. Forced air systems with high efficiency filtration were found to provide the best control of asthma triggers: 30-55% lower cat allergen levels, 90-99% lower risk of respiratory infection through the inhalation route of exposure, 90-98% lower environmental tobacco smoke (ETS) levels, and 50-75% lower fungal spore levels than the other ventilation/filtration systems considered. These results indicate that the use of high efficiency in-duct air cleaners provide an effective means of controlling allergen levels not only in a single room, like a portable air cleaner, but the whole house. These findings are useful for evaluating potential benefits of high efficiency in-duct filtration systems for controlling exposure to asthma triggers indoors and for the design of trials of environmental interventions intended to evaluate their utility in practice.
Control of asthma triggers in indoor air with air cleaners: a modeling analysis
Myatt, Theodore A; Minegishi, Taeko; Allen, Joseph G; MacIntosh, David L
2008-01-01
Background Reducing exposure to environmental agents indoors shown to increase asthma symptoms or lead to asthma exacerbations is an important component of a strategy to manage asthma for individuals. Numerous investigations have demonstrated that portable air cleaning devices can reduce concentrations of asthma triggers in indoor air; however, their benefits for breathing problems have not always been reproducible. The potential exposure benefits of whole house high efficiency in-duct air cleaners for sensitive subpopulations have yet to be evaluated. Methods We used an indoor air quality modeling system (CONTAM) developed by NIST to examine peak and time-integrated concentrations of common asthma triggers present in indoor air over a year as a function of natural ventilation, portable air cleaners, and forced air ventilation equipped with conventional and high efficiency filtration systems. Emission rates for asthma triggers were based on experimental studies published in the scientific literature. Results Forced air systems with high efficiency filtration were found to provide the best control of asthma triggers: 30–55% lower cat allergen levels, 90–99% lower risk of respiratory infection through the inhalation route of exposure, 90–98% lower environmental tobacco smoke (ETS) levels, and 50–75% lower fungal spore levels than the other ventilation/filtration systems considered. These results indicate that the use of high efficiency in-duct air cleaners provide an effective means of controlling allergen levels not only in a single room, like a portable air cleaner, but the whole house. Conclusion These findings are useful for evaluating potential benefits of high efficiency in-duct filtration systems for controlling exposure to asthma triggers indoors and for the design of trials of environmental interventions intended to evaluate their utility in practice. PMID:18684328
Hossain, Mohammad A; Quinlan, Amy; Heck-Kanellidis, Jennifer; Calderon, Dawn; Patel, Tejas; Gandhi, Bhavika; Patel, Shrinil; Hetavi, Mahida; Costanzo, Eric J; Cosentino, James; Patel, Chirag; Dewan, Asa; Kuo, Yen-Hong; Salman, Loay; Vachharajani, Tushar J
2018-07-01
While transradial approach to conduct percutaneous coronary interventions offers multiple advantages, the procedure can cause radial artery damage and occlusion. Because radial artery is the preferred site for the creation of an arteriovenous fistula to provide dialysis, patients with chronic kidney disease are particularly dependent on radial artery for their long-term survival. In this retrospective study, we investigated the prevalence of chronic kidney disease in patients undergoing coronary interventions via radial artery. Stage of chronic kidney disease was based on estimated glomerular filtration rate and National Kidney Foundation - Kidney Disease Outcomes Quality Initiative guidelines. A total of 497 patients undergoing transradial percutaneous coronary interventions were included. Over 70.4% (350/497) of the patients had chronic kidney disease. Stage II chronic kidney disease was observed in 243 (69%) patients (estimated glomerular filtration rate = 76.0 ± 8.4 mL/min). Stage III was observed in 93 (27%) patients (estimated glomerular filtration rate = 49 ± 7.5 mL/min). Stage IV chronic kidney disease was observed in 5 (1%) patients (estimated glomerular filtration rate = 25.6 ± 4.3 mL/min) and Stage V chronic kidney disease was observed in 9 (3%) patients (estimated glomerular filtration rate = 9.3 ± 3.5 mL/min). Overall, 107 of 350 patients (30%) had advanced chronic kidney disease, that is, stage III-V chronic kidney disease. Importantly, 14 of the 107 (13%) patients had either stage IV or V chronic kidney disease. This study finds that nearly one-third of the patients undergoing transradial percutaneous coronary interventions have advanced chronic kidney disease. Because many of these patients may require dialysis, the use of radial artery to conduct percutaneous coronary interventions must be carefully considered in chronic kidney disease population.
Acute kidney injury and cardiovascular outcomes in acute severe hypertension.
Szczech, Lynda A; Granger, Christopher B; Dasta, Joseph F; Amin, Alpesh; Peacock, W Frank; McCullough, Peter A; Devlin, John W; Weir, Matthew R; Katz, Jason N; Anderson, Frederick A; Wyman, Allison; Varon, Joseph
2010-05-25
Little is known about the association of kidney dysfunction and outcome in acute severe hypertension. This study aimed to measure the association between baseline chronic kidney disease (estimated glomerular filtration rate), acute kidney injury (AKI, decrease in estimated glomerular filtration rate > or =25% from baseline) and outcome in patients hospitalized with acute severe hypertension. The Studying the Treatment of Acute Hypertension (STAT) registry enrolled patients with acute severe hypertension, defined as > or =1 blood pressure measurement >180 mm Hg systolic and/or >110 mm Hg diastolic and treated with intravenous antihypertensive therapy. Data were compared across groups categorized by admission estimated glomerular filtration rate and AKI during admission. On admission, 79% of the cohort (n=1566) had at least mild chronic kidney disease (estimated glomerular filtration rate <60 mL/min in 46%, <30 mL/min in 22%). Chronic kidney disease patients were more likely to develop heart failure (P<0.0001), non-ST-elevation myocardial infarction (P=0.003), and AKI (P<0.007). AKI patients were at greater risk of heart failure and cardiac arrest (P< or =0.0001 for both). Subjects with AKI experienced higher mortality at 90 days (P=0.003). Any acute loss of estimated glomerular filtration rate during hospitalization was independently associated with an increased risk of death (odds ratio, 1.05; P=0.03 per 10-mL/min decline). Other independent predictors of mortality included increasing age (P<0.0001), male gender (P=0.016), white versus black race (P=0.003), and worse baseline kidney function (P=0.003). Chronic kidney disease is a common comorbidity among patients admitted with acute severe hypertension, and AKI is a frequent form of acute target organ dysfunction, particularly in those with baseline chronic kidney disease. Any degree of AKI is associated with a greater risk of morbidity and mortality.
Fine dust filtration using a metal fiber bed.
Lee, Kyung Mi; Lee, Young Sup; Jo, Young Min
2006-08-01
A bed-type filter composed of thin metal alloy fiber was closely examined with dust capturing in cold and hot runs. The investigation of an individual mechanism across the filter bed indicated that the aerated dust could be initially collected by depth filtration, and after a while, surface filtration dominated the overall dust collection. The present metal fiber bed was comparable to the conventional ceramic filters because of its good collection efficiency with low pressure drop. It also showed potential to be used as a prefilter in a diesel exhaust trapping system.
Suttels, Veronique; Florence, Eric; Leys, John; Vekemans, Marc; Van den Ende, Jef; Vlieghe, Erika; Kenyon, Chris
2015-09-08
We present what we believe to be the first case in the literature of rhabdomyolysis-induced renal failure caused by a probable drug interaction between elvitegravir/cobicistat/emtricitabine/tenofovir disoproxil fumarate (EVG/COBI/FTC/TDF) and pravastatin/fenofibrate. A 68-year old Caucasian man presented with progressive pain in both legs two weeks after commencing treatment with EVG/COBI/FTC/TDF. He was found to have biochemical evidence of rhabdomyolysis and acute renal failure. We emphasize the need for post marketing surveillance of adverse effects of new products. Pharmacokinetic studies are necessary to investigate the levels of pravastatin in patients taking COBI and fenofibrate with and without other comorbidities. Meanwhile, we suggest that creatine kinase levels should be monitored and patients advised to report myalgias when using concomitant EVG/COBI/FTC/TDF and pravastatin/fenofibrate. This case serves as an important reminder to use estimated glomerular filtration rates rather than serum creatinine levels when choosing new medications. If potentially nephrotoxic combinations are started in patients with borderline estimated glomerular filtration rates, it may be prudent to check these filtration rates more frequently than usual. In patients with reduced estimated glomerular filtration rates, potentially nephrotoxic combinations should be avoided wherever possible.
Advanced particulate matter control apparatus and methods
Miller, Stanley J [Grand Forks, ND; Zhuang, Ye [Grand Forks, ND; Almlie, Jay C [East Grand Forks, MN
2012-01-10
Apparatus and methods for collection and removal of particulate matter, including fine particulate matter, from a gas stream, comprising a unique combination of high collection efficiency and ultralow pressure drop across the filter. The apparatus and method utilize simultaneous electrostatic precipitation and membrane filtration of a particular pore size, wherein electrostatic collection and filtration occur on the same surface.
Membrane-less microfiltration using inertial microfluidics
Warkiani, Majid Ebrahimi; Tay, Andy Kah Ping; Guan, Guofeng; Han, Jongyoon
2015-01-01
Microfiltration is a ubiquitous and often crucial part of many industrial processes, including biopharmaceutical manufacturing. Yet, all existing filtration systems suffer from the issue of membrane clogging, which fundamentally limits the efficiency and reliability of the filtration process. Herein, we report the development of a membrane-less microfiltration system by massively parallelizing inertial microfluidics to achieve a macroscopic volume processing rates (~ 500 mL/min). We demonstrated the systems engineered for CHO (10–20 μm) and yeast (3–5 μm) cells filtration, which are two main cell types used for large-scale bioreactors. Our proposed system can replace existing filtration membrane and provide passive (no external force fields), continuous filtration, thus eliminating the need for membrane replacement. This platform has the desirable combinations of high throughput, low-cost, and scalability, making it compatible for a myriad of microfiltration applications and industrial purposes. PMID:26154774
Effect of work of adhesion on deep bed filtration process
NASA Astrophysics Data System (ADS)
Przekop, Rafał; Jackiewicz, Anna; WoŻniak, Michał; Gradoń, Leon
2016-06-01
Collection of aerosol particles in the particular steps of the technology of their production, and purification of the air at the workplace and atmospheric environment, requires the efficient method of separation of particulate matter from the carrier gas. There are many papers published in last few years in which the deposition of particles on fibrous collectors is considered, Most of them assume that collisions between particle and collector surface is 100% effective. In this work we study the influence of particles and fiber properties on the deposition efficiency. For the purpose of this work the lattice-Boltzmann model describes fluid dynamics, while the solid particle motion is modeled by the Brownian dynamics. The interactions between particles and surface are modelled using energy balanced oscillatory model. The work of adhesion was estimated using Atomic Force Microscopy.
Effect of work of adhesion on deep bed filtration process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Przekop, Rafał; Jackiewicz, Anna; Gradoń, Leon
2016-06-08
Collection of aerosol particles in the particular steps of the technology of their production, and purification of the air at the workplace and atmospheric environment, requires the efficient method of separation of particulate matter from the carrier gas. There are many papers published in last few years in which the deposition of particles on fibrous collectors is considered, Most of them assume that collisions between particle and collector surface is 100% effective. In this work we study the influence of particles and fiber properties on the deposition efficiency. For the purpose of this work the lattice-Boltzmann model describes fluid dynamics,more » while the solid particle motion is modeled by the Brownian dynamics. The interactions between particles and surface are modelled using energy balanced oscillatory model. The work of adhesion was estimated using Atomic Force Microscopy.« less
NASA Astrophysics Data System (ADS)
Zhu, Yuanzhi; Xu, Danyun; Zhao, Qingshan; Li, Yang; Peng, Wenchao; Zhang, Guoliang; Zhang, Fengbao; Fan, Xiaobin
2015-10-01
Porous organic frameworks (POFs) based membranes have potential applications in molecular filtration, despite the lack of a corresponding study. This study reports an interesting strategy to get processable POFs dispersion and a novel ultrathin sandwich-like membrane design. It was accidentally found that the hydrophobic N-rich Schiff based POFs agglomerates could react with lithium-ethylamine and formed stable dispersion in water. By successively filtrating the obtained POFs dispersion and graphene oxide (GO), we successfully prepared ultrathin sandwich-like hybrid membranes with layered structure, which showed significantly improved separation efficiency in molecular filtration of organic dyes. This study may provide a universal way to the preparation of processable POFs and their hybrid membranes with GO.
NASA Astrophysics Data System (ADS)
Kishkovich, Oleg P.; Bolgov, Dennis; Goodwin, William
1999-06-01
In this paper, the authors discuss the requirements for chemical air filtration system used in conjunction with modern DUV photolithography equipment. Among the topics addressed are the scope of pollutants, their respective internal and external sources, and an overview of different types of filtration technologies currently in use. Key filtration parameters, including removal efficiency, service life, and spill protection capacity, are discussed and supported by actual data, reflection the total molecular base concentration in operational IC manufacturing facilities. The authors also describe a time-accelerated testing procedure for comparing and evaluating different filtration technologies and designs, and demonstrate how this three-day test procedure can reliably predict an effective filter service life up to ten years.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azhar, A.; Hamdy, M.K.
Use of ultrafiltration membrane systems in stirred cell and in thin-channel systems for immobilizing enzyme (sweet potato intrinsic and crystalline /beta/-amylase) in hydrolysis of sweet potato through a continuous operation mode were studied. Both the filtration rate and reducing sugars, produced as the result of enzymatic hydrolysis, decreased with the filtration time. THe immobilized enzymes in the thin-channel system showed a much better performance compared to that in the stirred cell system. Addition of crystalline sweet potato /beta/-amylase to the sweet potato increased both the filtration rate and reducing-sugars content. Alcoholic fermentation of the filtrate resulted in an alcohol contentmore » of 4.2%. This represented fermentation of 95% of the sugars with an efficiency of 88%. 17 refs.« less
Lambertini, Elisabetta; Spencer, Susan K.; Bertz, Phillip D.; Loge, Frank J.; Kieke, Burney A.; Borchardt, Mark A.
2008-01-01
Available filtration methods to concentrate waterborne viruses are either too costly for studies requiring large numbers of samples, limited to small sample volumes, or not very portable for routine field applications. Sodocalcic glass wool filtration is a cost-effective and easy-to-use method to retain viruses, but its efficiency and reliability are not adequately understood. This study evaluated glass wool filter performance to concentrate the four viruses on the U.S. Environmental Protection Agency contaminant candidate list, i.e., coxsackievirus, echovirus, norovirus, and adenovirus, as well as poliovirus. Total virus numbers recovered were measured by quantitative reverse transcription-PCR (qRT-PCR); infectious polioviruses were quantified by integrated cell culture (ICC)-qRT-PCR. Recovery efficiencies averaged 70% for poliovirus, 14% for coxsackievirus B5, 19% for echovirus 18, 21% for adenovirus 41, and 29% for norovirus. Virus strain and water matrix affected recovery, with significant interaction between the two variables. Optimal recovery was obtained at pH 6.5. No evidence was found that water volume, filtration rate, and number of viruses seeded influenced recovery. The method was successful in detecting indigenous viruses in municipal wells in Wisconsin. Long-term continuous filtration retained viruses sufficiently for their detection for up to 16 days after seeding for qRT-PCR and up to 30 days for ICC-qRT-PCR. Glass wool filtration is suitable for large-volume samples (1,000 liters) collected at high filtration rates (4 liters min−1), and its low cost makes it advantageous for studies requiring large numbers of samples. PMID:18359827
Removal of Cryptosporidium parvum in bank filtration systems
NASA Astrophysics Data System (ADS)
Harter, T.; Atwill, E. R.; Hou, L. L.
2003-04-01
The protozoan pathogen Cryptosporidium parvum is a leading cause of waterborne disease. Many surface water systems therefore depend on filtration systems, including bank filtration systems, for the removal of the pathogenic oocysts. To better understand the effectiveness, e.g., of bank filtration systems, we have implemented a series of columns studies under various environmental conditions (column length: 10 cm - 60 cm, flow rates: 0.7 m/d - 30 m/d, ionic strength: 0.01 - 100 mM, filter grain size: 0.2 - 2 mm, various solution chemistry). We show that classic colloid filtration theory is a reasonable tool for predicting the initial breakthrough of C. parvum in pulsed injections of the oocyst through sand columns, although the model does not account for the significant tailing that occurs in C. parvum transport. Application of colloid filtration theory to bank filtration system is further limited by the intrinsic heterogeneity of the geologic systems used for bank filtration. We couple filtration theory with a stochastic subsurface transport approach and with percolation theory to account for the effects of intrinsic heterogeneity. We find that a 1-log removal can be achieved even under relatively adverse conditions (low collision efficiency, high velocity) if 85% - 90% of the sedimentary hydrofacies located within the bank filtration system or of the coarsest known hydrofacies connecting the riverbed with the extraction system has a grain-size distribution with a 10% passing diameter equal to 1 mm. One millimeter is a standard sieve size in sediment analysis.
2006-01-01
Abstract The purpose of this study was to compare 3 methods for the reduction of aerosol transmission of Porcine reproductive and respiratory syndrome virus (PRRSV): high-efficiency particulate air (HEPA) filtration, low-cost filtration, and ultraviolet light (UV) irradiation. The HEPA-filtration system involved a pre-filter screen, a bag filter (EU8 rating), and a HEPA filter (EU13 rating). The low-cost-filtration system contained mosquito netting (pre-filter), a fiberglass furnace filter, and an electrostatic furnace filter. For UV irradiation, a lamp emitted UVC radiation at 253.7 nm. No form of intervention was used in the control group. The experimental facilities consisted of 2 chambers connected by a 1.3-m-long duct. Recipient pigs, housed in chamber 2, were exposed to artificial aerosols created by a mechanically operated mister containing modified live PRRSV vaccine located in chamber 1. Aerosol transmission of PRRSV occurred in 9 of the 10 control replicates, 8 of the 10 UVC-irradiation replicates, 4 of the 10 low-cost-filtration replicates, and 0 of the 10 HEPA-filtration replicates. When compared with no intervention, HEPA filtration and low-cost filtration significantly reduced PRRSV transmission (P < 0.0005 and = 0.0286, respectively), whereas UV irradiation had no effect (P = 0.5). However, low-cost filtration and UV irradiation were significantly less effective (P = 0.043 and P < 0.0005, respectively) than HEPA filtration. In conclusion, under the conditions of this study, HEPA filtration was significantly more effective at reducing aerosol transmission of PRRSV than the other methods evaluated. PMID:16548329
Noll, J.D.; Cecala, A.B.; J.A.Organiscak; Rider, J.P.
2015-01-01
An effective technique to minimize miners’ respirable dust and diesel exposure on mobile mining equipment is to place mine operators in enclosed cabs with designed filtration and pressurization systems. Many factors affect the performance of these enclosed cab systems, and one of the most significant factors is the effectiveness of the filtration system. High-efficiency particulate air (HEPA)-type filters are typically used because they are highly efficient at capturing all types and sizes of particles, including those in the submicron range such as diesel particulate matter (DPM). However, in laboratory tests, minimum efficiency reporting value (MERV) 16 filters have proven to be highly efficient for capturing DPM and respirable dust. Also, MERV 16 filters can be less restrictive to cab airflow and less expensive than HEPA filters. To verify their effectiveness in the field, MERV 16 filters were used in the enclosed cab filtration system on a face drill and roof bolting mining machine and tested at an underground limestone mine. Test results showed that DPM and respirable dust concentrations were reduced by more than 90% when the cabs were properly sealed. However, when the cab door was opened periodically throughout the shift, the reduction efficiency of the MERV 16 filters was reduced to 80% on average. PMID:26236044
Modification of the TASMIP x-ray spectral model for the simulation of microfocus x-ray sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sisniega, A.; Vaquero, J. J., E-mail: juanjose.vaquero@uc3m.es; Instituto de Investigación Sanitaria Gregorio Marañón, Madrid ES28007
2014-01-15
Purpose: The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammography. However, most of these models cannot be used directly for modeling microfocus x-ray sources due to differences in inherent filtration, energy range and/or anode material. For this reason the authors propose in this work a new model for the simulation of microfocus spectra based on existing models for mammography and radiology, modifiedmore » to compensate for the effects of inherent filtration and energy range. Methods: The authors used the radiology and mammography versions of an existing empirical model [tungsten anode spectral model interpolating polynomials (TASMIP)] as the basis of the microfocus model. First, the authors estimated the inherent filtration included in the radiology model by comparing the shape of the spectra with spectra from the mammography model. Afterwards, the authors built a unified spectra dataset by combining both models and, finally, they estimated the parameters of the new version of TASMIP for microfocus sources by calibrating against experimental exposure data from a microfocus x-ray source. The model was validated by comparing estimated and experimental exposure and attenuation data for different attenuating materials and x-ray beam peak energy values, using two different x-ray tubes. Results: Inherent filtration for the radiology spectra from TASMIP was found to be equivalent to 1.68 mm Al, as compared to spectra obtained from the mammography model. To match the experimentally measured exposure data the combined dataset required to apply a negative filtration of about 0.21 mm Al and an anode roughness of 0.003 mm W. The validation of the model against real acquired data showed errors in exposure and attenuation in line with those reported for other models for radiology or mammography. Conclusions: A new version of the TASMIP model for the estimation of x-ray spectra in microfocus x-ray sources has been developed and validated experimentally. Similarly to other versions of TASMIP, the estimation of spectra is very simple, involving only the evaluation of polynomial expressions.« less
Fast Simulation of Membrane Filtration by Combining Particle Retention Mechanisms and Network Models
NASA Astrophysics Data System (ADS)
Krupp, Armin; Griffiths, Ian; Please, Colin
2016-11-01
Porous membranes are used for their particle retention capabilities in a wide range of industrial filtration processes. The underlying mechanisms for particle retention are complex and often change during the filtration process, making it hard to predict the change in permeability of the membrane during the process. Recently, stochastic network models have been shown to predict the change in permeability based on retention mechanisms, but remain computationally intensive. We show that the averaged behaviour of such a stochastic network model can efficiently be computed using a simple partial differential equation. Moreover, we also show that the geometric structure of the underlying membrane and particle-size distribution can be represented in our model, making it suitable for modelling particle retention in interconnected membranes as well. We conclude by demonstrating the particular application to microfluidic filtration, where the model can be used to efficiently compute a probability density for flux measurements based on the geometry of the pores and particles. A. U. K. is grateful for funding from Pall Corporation and the Mathematical Institute, University of Oxford. I.M.G. gratefully acknowledges support from the Royal Society through a University Research Fellowship.
Modeling filtration and fouling with a microstructured membrane filter
NASA Astrophysics Data System (ADS)
Cummings, Linda; Sanaei, Pejman
2017-11-01
Membrane filters find widespread use in diverse applications such as A/C systems and water purification. While the details of the filtration process may vary significantly, the broad challenge of efficient filtration is the same: to achieve finely-controlled separation at low power consumption. The obvious resolution to the challenge would appear simple: use the largest pore size consistent with the separation requirement. However, the membrane characteristics (and hence the filter performance) are far from constant over its lifetime: the particles removed from the feed are deposited within and on the membrane filter, fouling it and degrading the performance over time. The processes by which this occurs are complex, and depend on several factors, including: the internal structure of the membrane and the type of particles in the feed. We present a model for fouling of a simple microstructured membrane, and investigate how the details of the microstructure affect the filtration efficiency. Our idealized membrane consists of bifurcating pores, arranged in a layered structure, so that the number (and size) of pores changes in the depth of the membrane. In particular, we address how the details of the membrane microstructure affect the filter lifetime, and the total throughput. NSF DMS 1615719.
Production of a ruminant protein supplement by anaerobic fermentation of feedlot waste filtrate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reddy, C.A.; Erdman, M.D.
1977-01-01
In studies initiated to develop simple and efficient procedures for the production of feed supplements, it was shown that the filtrate from feedlot wastes diluted with water and filtered could be fermented under anaerobic conditions by mixed rumen bacteria, Lactobacilli, or natural microflora from the feedlot wastes to produce a protein-rich feed supplement. The filtrate is low in carbohydrate and therefore supplemental carbohydrate in the form of whey, molasses, starch from potato processing wastes, or corn starch is necessary. Rigid anaerobic conditions need not be maintained nor must aseptic conditions be observed. (JSR)
Removal of trace metal contaminants from potable water by electrocoagulation.
Heffron, Joe; Marhefke, Matt; Mayer, Brooke K
2016-06-21
This study investigated the effects of four operational and environmental variables on the removal of trace metal contaminants from drinking water by electrocoagulation (EC). Removal efficiencies for five metals (arsenic, cadmium, chromium, lead and nickel) were compared under varying combinations of electrode material, post-treatment, water composition and pH. Iron electrodes out-performed aluminum electrodes in removing chromium and arsenic. At pH 6.5, aluminum electrodes were slightly more effective at removing nickel and cadmium, while at pH 8.5, iron electrodes were more effective for these metals. Regardless of electrode, cadmium and nickel removal efficiencies were higher at pH 8.5 than at pH 6.5. Post-EC treatment using membrane filtration (0.45 μm) enhanced contaminant removal for all metals but nickel. With the exception of lead, all metals exhibited poorer removal efficiencies as the ionic strength of the background electrolyte increased, particularly in the very high-solids synthetic groundwaters. Residual aluminum concentrations were lowest at pH 6.5, while iron residuals were lowest in low ionic strength waters. Both aluminum and iron residuals required post-treatment filtration to meet drinking water standards. EC with post-treatment filtration appears to effectively remove trace metal contaminants to potable water standards, but both reactor and source water parameters critically impact removal efficiency.
Removal of trace metal contaminants from potable water by electrocoagulation
NASA Astrophysics Data System (ADS)
Heffron, Joe; Marhefke, Matt; Mayer, Brooke K.
2016-06-01
This study investigated the effects of four operational and environmental variables on the removal of trace metal contaminants from drinking water by electrocoagulation (EC). Removal efficiencies for five metals (arsenic, cadmium, chromium, lead and nickel) were compared under varying combinations of electrode material, post-treatment, water composition and pH. Iron electrodes out-performed aluminum electrodes in removing chromium and arsenic. At pH 6.5, aluminum electrodes were slightly more effective at removing nickel and cadmium, while at pH 8.5, iron electrodes were more effective for these metals. Regardless of electrode, cadmium and nickel removal efficiencies were higher at pH 8.5 than at pH 6.5. Post-EC treatment using membrane filtration (0.45 μm) enhanced contaminant removal for all metals but nickel. With the exception of lead, all metals exhibited poorer removal efficiencies as the ionic strength of the background electrolyte increased, particularly in the very high-solids synthetic groundwaters. Residual aluminum concentrations were lowest at pH 6.5, while iron residuals were lowest in low ionic strength waters. Both aluminum and iron residuals required post-treatment filtration to meet drinking water standards. EC with post-treatment filtration appears to effectively remove trace metal contaminants to potable water standards, but both reactor and source water parameters critically impact removal efficiency.
Gu, Liubao; Huang, Liji; Wu, Haidi; Lou, Qinglin; Bian, Rongwen
2017-05-01
Serum uric acid has shown to be a predictor of renal disease progression in most but not all studies. This study aims to test whether renal function-normalized serum uric acid is superior to serum uric acid as the predictor of incident chronic kidney disease in type 2 diabetes mellitus patients. In this study, 1339 type 2 diabetes mellitus patients with estimated glomerular filtration rate ⩾60 mL/min/1.73 m 2 and normouricemia were included. Renal function-normalized serum uric acid was calculated using serum uric acid/creatinine. Cox regression analysis was used to estimate the association between serum uric acid, renal function-normalized serum uric acid and incident chronic kidney disease. In total, 74 (5.53%) patients developed to chronic kidney disease 3 or greater during a median follow-up of 4 years, with older ages, longer diabetes duration and lower estimated glomerular filtration rate at baseline. The decline rate of estimated glomerular filtration rate was positively correlated with serum uric acid/creatinine ( r = 0.219, p < 0.001), but not serum uric acid ( r = 0.005, p = 0.858). Moreover, multivariate analysis revealed that serum uric acid was not an independent risk factor for incident chronic kidney disease ( p = 0.055), whereas serum uric acid to creatinine ratio was significantly associated with incident chronic kidney disease independently of potential confounders including baseline estimated glomerular filtration rate. serum uric acid to creatinine ratio might be a better predictor of incident chronic kidney disease in type 2 diabetes mellitus patients.
Withington, S; Chambers, S T; Beard, M E; Inder, A; Allen, J R; Ikram, R B; Schousboe, M I; Heaton, D C; Spearing, R I; Hart, D N
1998-01-01
The impact of intranasal amphotericin B and high-efficiency particulate air (HEPA) filtration on the incidence of invasive aspergillosis was reviewed in patients from 1977 to 1994 undergoing intensive chemotherapy. Overall, the incidence of proven invasive aspergillosis was reduced from 24.4% (1977-1984) to 7.1% (1985-1991) (P < 0.001) following the introduction of intranasal prophylaxis, but when probable cases of aspergillosis were included and lymphoma cases excluded, there was no change in incidence. Following the introduction of HEPA filtration, patient exposure to aspergillus spores as measured by air sampling was markedly reduced and there were no new cases of invasive aspergillosis. HEPA filtration proved effective in reducing invasive aspergillosis and has allowed increasingly aggressive treatment regimens to be introduced.
NASA Astrophysics Data System (ADS)
Messina, F.; Tosco, T.; Sethi, R.
2017-12-01
Colloidal transport and deposition in saturated porous media are phenomena of considerable importance in a large number of natural processes and engineering applications, such as the contaminant and microorganism propagation in aquifer systems, the development of innovative groundwater remediation technologies, air and water filtration, and many others. Therefore, a thorough understanding of particle filtration is essential for predicting the transport and fate of colloids in the subsurface environment. The removal efficiency of a filter is a key aspect for colloid transport in porous media. Several efforts were devoted to derive accurate correlations for the single collector efficiency, one of the key concept in the filtration theory. However, up scaling this parameter to the entire porous medium is still a challenge. The common up-scaling approach assumes the deposition to be independent of the transport history, which means that the collector efficiency is considered uniform along the porous medium. However, previous works showed that this approach is inadequate under unfavorable deposition conditions. This study demonstrates that it is not adequate even in the simplest case of favorable deposition. Computational Fluid Dynamics simulations were run for a simplify porous media geometry, composed of a vertical array of 50 identical spherical collectors. A combination of Lagrangian and Eulerian simulations were performed to analyze the particle transport under a broad range of parameters (i.e., particle size, particle density, water velocity). The results show the limits of the existing models to interpret the experimental data. In fact, the outcome evidenced that when particle deposition is not controlled by Brownian diffusion, non-exponential concentration profiles are retrieved, in contrast with the assumption of uniform efficiency. Moreover, when the deposition mechanisms of sedimentation and interception dominate, the efficiency of the first sphere of the column is significantly higher compared to the others, and then it declines along the array down to an asymptotic value. A more rigorous procedure to evaluate the filtration processes in presence of a series of collectors was developed, and a new correlation for the up-scaled removal efficiency of the entire array was derived and proposed.
Park, Jae Hong; Yoon, Ki Young; Na, Hyungjoo; Kim, Yang Seon; Hwang, Jungho; Kim, Jongbaeg; Yoon, Young Hun
2011-09-01
We grew multi-walled carbon nanotubes (MWCNTs) on a glass fiber air filter using thermal chemical vapor deposition (CVD) after the filter was catalytically activated with a spark discharge. After the CNT deposition, filtration and antibacterial tests were performed with the filters. Potassium chloride (KCl) particles (<1 μm) were used as the test aerosol particles, and their number concentration was measured using a scanning mobility particle sizer. Antibacterial tests were performed using the colony counting method, and Escherichia coli (E. coli) was used as the test bacteria. The results showed that the CNT deposition increased the filtration efficiency of nano and submicron-sized particles, but did not increase the pressure drop across the filter. When a pristine glass fiber filter that had no CNTs was used, the particle filtration efficiencies at particle sizes under 30 nm and near 500 nm were 48.5% and 46.8%, respectively. However, the efficiencies increased to 64.3% and 60.2%, respectively, when the CNT-deposited filter was used. The reduction in the number of viable cells was determined by counting the colony forming units (CFU) of each test filter after contact with the cells. The pristine glass fiber filter was used as a control, and 83.7% of the E. coli were inactivated on the CNT-deposited filter. Copyright © 2011 Elsevier B.V. All rights reserved.
Fan, Xinfei; Zhao, Huimin; Liu, Yanming; Quan, Xie; Yu, Hongtao; Chen, Shuo
2015-02-17
Membrane filtration provides effective solutions for removing contaminants, but achieving high permeability, good selectivity, and antifouling ability remains a great challenge for existing membrane filtration technologies. In this work, membrane filtration coupled with electrochemistry has been developed to enhance the filtration performance of a CNTs/Al2O3 membrane. The as-prepared CNTs/Al2O3 membrane, obtained by coating interconnected CNTs on an Al2O3 substrate, presented good pore-size tunability, mechanical stability, and electroconductivity. For the removal of a target (silica spheres as a probe) with a size comparable to the membrane pore size, the removal efficiency and flux at +1.5 V were 1.1 and 1.5 times higher, respectively, than those without electrochemical assistance. Moreover, the membrane also exhibited a greatly enhanced removal efficiency for contaminants smaller than the membrane pores, providing enhancements of 4 orders of magnitude and a factor of 5.7 for latex particles and phenol, respectively. These results indicated that both the permeability and the selectivity of CNTs/Al2O3 membranes can be significantly improved by electrochemical assistance, which was further confirmed by the removal of natural organic matter (NOM). The permeate flux and NOM removal efficiency at +1.5 V were about 1.6 and 3.0 times higher, respectively, than those without electrochemical assistance. In addition, the lost flux of the fouled membrane was almost completely recovered by an electrochemically assisted backwashing process.
Maremar, prevalence of chronic kidney disease, how to avoid over-diagnosis and under-diagnosis.
De Broe, Marc E; Gharbi, Mohammed Benghanem; Elseviers, Monique
2016-04-01
Chronic kidney disease is considered as a major public health problem. Recent studies mention a prevalence rate between 8%-12%. Several editorials, comments, short reviews described the weaknesses (lack of confirmation of proteinuria, and of chronicity of decreased estimated glomerular filtration rate) of a substantial number of studies and the irrational of using a single arbitrary set point, i.e. diagnosis of chronic kidney disease whenever the estimated glomerular filtration rate is less than 60mL/min/1.73m(2). Maremar (Maladies rénales chroniques au Maroc) is a prevalence study of chronic kidney disease, hypertension, diabetes and obesity in a randomized, representative, high response rate (85%), sample of the adult population of Morocco, strictly applying the Kidney Disease: Improving Global Outcomes (KDIGO) criteria. Compared to the vast majority of the available studies, Maremar has a low prevalence of chronic kidney disease (2.9% adjusted to the actual adult population of Morocco). The population pyramid, and particularly the confirmation of proteinuria and "chronicity" of the decreased estimated glomerular filtration rate are the main reasons for this low prevalence of chronic kidney disease. The choice of arbitrary single threshold of estimated glomerular filtration rate for classifying stage 3-5 chronic kidney disease inevitably leads to "over-diagnosis" (false positives) of the disease in the elderly, particularly those without proteinuria, hematuria or hypertension, and to "under-diagnosed" (false negatives) in younger individuals with an estimated glomerular filtration rate above 60mL/min/1.73m(2) and below the 3rd percentile of their age/gender category. There is an urgent need for quality studies using in a correct way the recent KDIGO guidelines when investigating the prevalence of chronic kidney disease, in order to avoid a 50 to 100% overestimation of a disease state with potential dramatic consequences. The combination of the general population screening encompassing four different major health problems in the same screening procedure, using the correct methodologies and procedures, combined with a prevention/follow-up program results in a clinically/scientifically relevant program. Copyright © 2016 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.
Kim, Dae Keun; Jang, Yujin; Lee, Jaeseon; Hong, Helen; Kim, Ki Hong; Shin, Tae Young; Jung, Dae Chul; Choi, Young Deuk; Rha, Koon Ho
2015-12-01
To analyze long-term changes in both kidneys, and to predict renal function and contralateral hypertrophy after robot-assisted partial nephrectomy. A total of 62 patients underwent robot-assisted partial nephrectomy, and renal parenchymal volume was calculated using three-dimensional semi-automatic segmentation technology. Patients were evaluated within 1 month preoperatively, and postoperatively at 6 months, 1 year and continued up to 2-year follow up. Linear regression models were used to identify the factors predicting variables that correlated with estimated glomerular filtration rate changes and contralateral hypertrophy 2 years after robot-assisted partial nephrectomy. The median global estimated glomerular filtration rate changes were -10.4%, -11.9%, and -2.4% at 6 months, 1 and 2 years post-robot-assisted partial nephrectomy, respectively. The ipsilateral kidney median parenchymal volume changes were -24%, -24.4%, and -21% at 6 months, 1 and 2 years post-robot-assisted partial nephrectomy, respectively. The contralateral renal volume changes were 2.3%, 9.6% and 12.9%, respectively. On multivariable linear analysis, preoperative estimated glomerular filtration rate was the best predictive factor for global estimated glomerular filtration rate change on 2 years post-robot-assisted partial nephrectomy (B -0.452; 95% confidence interval -0.84 to -0.14; P = 0.021), whereas the parenchymal volume loss rate (B -0.43; 95% confidence interval -0.89 to -0.15; P = 0.017) and tumor size (B 5.154; 95% confidence interval -0.11 to 9.98; P = 0.041) were the significant predictive factors for the degree of contralateral renal hypertrophy on 2 years post-robot-assisted partial nephrectomy. Preoperative estimated glomerular filtration rate significantly affects post-robot-assisted partial nephrectomy renal function. Renal mass size and renal parenchyma volume loss correlates with compensatory hypertrophy of the contralateral kidney. Contralateral hypertrophy of the renal parenchyma compensates for the functional loss of the ipsilateral kidney. © 2015 The Japanese Urological Association.
[Effect of ozone on membrane fouling in water and wastewater treatment: a research review].
Zhu, Hong-tao; Wen, Xiang-hua; Huang, Xia
2009-01-01
As a high efficient water and wastewater treatment technology, membrane filtration has been mainly used in wastewater treatment as membrane bioreactor, in reclaiming secondary effluent,treating surface water and potable water, and etc. Membrane fouling is a main obstacle to the wide application of membrane technology. Ozone has strong oxidizing power and has been utilized widely in water and wastewater treatment. In recent years, researches on combined process of ozone-membrane filtration are increasing. This paper does reviews and analysis of these researches. It is noticed that there has been a few of researches on the ozone treatment plus MBR process. Pre-ozonation of feed to MBR and slight ozonation of the mixed liquid in MBR may be used to relieve membrane fouling.Combined processes of ozone-membrane filtration can be divided into three classes in terms of the function of ozone and the system configuration: (1) cleaning the fouled membrane with ozone; (2) separate ozone-membrane filtration process; (3) integrated ozone-membrane filtration process. Although most reports supported that ozonation can control membrane fouling development,there were contrary results. At present, researches on the mechanisms of ozone's effect on membrane fouling control concentrated on the change of organic composition of the filtration influent under ozonation, however, particulate substances, microbial and inorganic substances may also be affected and then play roles in membrane fouling, depending on source water quality and process configuration. Moreover, there have not been common parameters to evaluate the ozone diffusion equipment and efficiency. The authors suggest that further researches should emphasize on integrated ozone-membrane process, and more attention should be paid to the cost-effectiveness of the combined process.
Normalization and extension of single-collector efficiency correlation equation
NASA Astrophysics Data System (ADS)
Messina, Francesca; Marchisio, Daniele; Sethi, Rajandrea
2015-04-01
The colloidal transport and deposition are important phenomena involved in many engineering problems. In the environmental engineering field the use of micro- and nano-scale zerovalent iron (M-NZVI) is one of the most promising technologies for groundwater remediation. Colloid deposition is normally studied from a micro scale point of view and the results are then implemented in macro scale models that are used to design field-scale applications. The single collector efficiency concept predicts particles deposition onto a single grain of a complex porous medium in terms of probability that an approaching particle would be retained on the solid grain. In literature, many different approaches and equations exist to predict it, but most of them fail under specific conditions (e.g. very small or very big particle size and very low fluid velocity) because they predict efficiency values exceeding unity. By analysing particle fluxes and deposition mechanisms and performing a mass balance on the entire domain, the traditional definition of efficiency was reformulated and a novel total flux normalized correlation equation is proposed for predicting single-collector efficiency under a broad range of parameters. It has been formulated starting from a combination of Eulerian and Lagrangian numerical simulations, performed under Smoluchowski-Levich conditions, in a geometry which consists of a sphere enveloped by a control volume. In order to guarantee the independence of each term, the correlation equation is derived through a rigorous hierarchical parameter estimation process, accounting for single and mutual interacting transport mechanisms. The correlation equation provides efficiency values lower than one over a wide range of parameters and is valid both for point and finite-size particles. A reduced form is also proposed by elimination of the less relevant terms. References 1. Yao, K. M.; Habibian, M. M.; Omelia, C. R., Water and Waste Water Filtration - Concepts and Applications. Environ Sci Technol 1971, 5, (11), 1105-&. 2. Tufenkji, N., and M. Elimelech, Correlation equation for predicting single-collector efficiency in physicochemical filtration in saturated porous media. Environmental Science & Technology 2004 38(2):529-536. 3. Boccardo, G.; Marchisio, D. L.; Sethi, R., Microscale simulation of particle deposition in porous media. J Colloid Interface Sci 2014, 417, 227-37
Kong, Jianlei; Ding, Xiaokang; Liu, Jinhao; Yan, Lei; Wang, Jianli
2015-01-01
In this paper, a new algorithm to improve the accuracy of estimating diameter at breast height (DBH) for tree trunks in forest areas is proposed. First, the information is collected by a two-dimensional terrestrial laser scanner (2DTLS), which emits laser pulses to generate a point cloud. After extraction and filtration, the laser point clusters of the trunks are obtained, which are optimized by an arithmetic means method. Then, an algebraic circle fitting algorithm in polar form is non-linearly optimized by the Levenberg-Marquardt method to form a new hybrid algorithm, which is used to acquire the diameters and positions of the trees. Compared with previous works, this proposed method improves the accuracy of diameter estimation of trees significantly and effectively reduces the calculation time. Moreover, the experimental results indicate that this method is stable and suitable for the most challenging conditions, which has practical significance in improving the operating efficiency of forest harvester and reducing the risk of causing accidents. PMID:26147726
Although studied extensively in recent years in Europe, the occurrence of endocrine disrupters and other organic wastewater compounds in the environment in the United States is not well documented. To better understand the efficiency of riverbank filtration with respect to endoc...
Hong, Shen; Xian-Chun, Tang; Nan-Xiang, Wu; Hong-Bin, Chen
2018-07-01
The application of ozone-biological activated carbon (O 3 -BAC) as an advanced treatment method in drinking water treatment plants (DWTPs) can help to remove organic micropollutants and further decrease the dissolved organic carbon (DOC) level in finished water. With the increase attention to microbial safety of drinking water, a pre-positioned O 3 -BAC followed by a sand filter has been implanted into DWTP located in Shanghai, China to increase the biostability of effluents. The results showed that BAC had high removal efficiencies of UV 254 , DOC and disinfection by-product formation potential (DBPFP). The removal efficiencies between pre- and post-positioned BAC filtrations were similar. Based on the analyses of fluorescence excitation-emission matrix spectrophotometry (FEEM), the generation and leakage of soluble microbial products (SMPs) were found in both two BAC filtrations on account of the increased fluorescence intensities and fluorescence regional integration (FRI) distribution of protein-like organics, as well as the enhanced biological index (BIX). The leakage of SMPs produced by metabolism of microbes during BAC process resulted in increased DBPFP yield and carcinogenic factor per unit of DOC (CF/DOC). Although BAC filtration reduced the DBPFP and CF, there still was high health risk of effluents for the production of SMPs. Therefore, the health risks for SMPs generated by BAC filtration in drinking water advanced treatment process should be addressed, especially with that at high temperature. Copyright © 2018 Elsevier Ltd. All rights reserved.
Recycled PET Nanofibers for Water Filtration Applications
Zander, Nicole E.; Gillan, Margaret; Sweetser, Daniel
2016-01-01
Water shortage is an immediate and serious threat to our world population. Inexpensive and scalable methods to clean freshwater and wastewater are in high demand. Nanofiber filtration membranes represent a next generation nonwoven filter media due to their unique properties. Polyethlyene terephthalate (PET) is often used in the packaging of water and other commonly used materials, leading to a large amount of plastic waste often with limited incentive for recycling (few value-added uses). Here, we present work in the generation of nanofiber liquid filtration membranes from PET plastic bottles and demonstrate their use in microfiltration. PET nanofiber membranes were formed via solution electrospinning with fiber diameters as low as ca. 100 nm. Filtration efficiency was tested with latex beads with sizes ranging from 30 to 2000 nm. Greater than 99% of the beads as small as 500 nm were removed using gravity filtration. To reduce biofouling, the mats were functionalized with quaternary ammonium and biguanide biocides. The biguanide functionalized mats achieved 6 log reduction for both gram negative and gram positive bacteria. PMID:28773380
Elcik, Harun; Cakmakci, Mehmet
2017-06-01
The purpose of this study was to investigate the efficient harvesting of microalgal biomass through crossflow membrane filtration. The microalgal biomass harvesting experiments were performed using one microfiltration membrane (pore size: 0.2 µm, made from polyvinylidene fluoride) and three ultrafiltration membranes (molecular weight cut-off: 150, 50, and 30 kDa, made from polyethersulfone, hydrophilic polyethersulfone, and regenerated cellulose, respectively). Initially, to minimize membrane fouling caused by microalgal cells, experiments with the objective of determining the critical flux were performed. Based on the critical flux calculations, the best performing membrane was confirmed to be the UH050 membrane, produced from hydrophilic polyethersulfone material. Furthermore, we also evaluated the effect of transmembrane pressure (TMP) and crossflow velocity (CFV) on filtration flux. It was observed that membrane fouling was affected not only by the membrane characteristics, but also by the TMP and CFV. In all the membranes, it was observed that increasing CFV was associated with increasing filtration flux, independent of the TMP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, C; Yu, L; Vrieze, T
Purpose: Added filtration such as tin filter has the potential to improve dose efficiency of x-ray beam in lung-cancer screening CT. However, dose efficiency with added beam filtration is highly dependent on patient attenuation level. In this phantom study, we evaluated the image quality at different tube voltages with and without added tin filter when attenuation level varies. Methods: A 30 x 20 cm anthropomorphic thorax phantom with three added extension rings were used to simulate small (S), medium (M), large (L), and extra-large (XL) adult patients. These phantoms were scanned on a 192-slice CT scanner (Force, Siemens) at 100more » and 120kV without tin filtration, and 100 and 150 kV with tin filtration (100Sn and 150Sn), at multiple dose levels at each kV. Images were reconstructed using iterative reconstruction (ADMIRE, Siemens). Radiation dose was measured with a 0.6 cc ion chamber in the middle and peripheral areas of the phantom. Image quality was assessed using mean image noise at uniform areas in the central region and lung. Radiation dose that is required for each kV to match the noise in a routine lung-cancer CT screening technique (120kV, 25 quality reference mAs) was calculated. Results: At each of the four phantom sizes, 100Sn had the lowest noise in both soft tissue and lung. Compared with 120 kV, 100Sn saved 39%–60% dose for the same noise, depending on phantom size. For the XL phantom (50 by 40 cm), 150Sn provided images with the least beam-hardening artifact in peripheral region. Conclusion: For thoracic CT, added tin filtration can provide considerable dose reduction compared with 120 kV. 100Sn provides better dose efficiencies for all phantom sizes, while 150Sn provides better image quality in peripheral region for extra-large patients. Drs.Joel G. Fletcher and Cynthia H. McCollough receive research support from Siemens Healthcare.« less
Gumińska, Jolanta; Kłos, Marcin
2015-01-01
Filtration efficiency in a conventional water treatment system was analyzed in the context of pre-hydrolyzed coagulant overdosing. Two commercial coagulants of different aluminum speciation were tested. A study was carried out at a water treatment plant supplied with raw water of variable quality. The lack of stability of water quality caused many problems with maintaining the optimal coagulant dose. The achieved results show that the type of coagulant had a very strong influence on the effectiveness of filtration resulting from the application of an improper coagulant dose. The overdosing of high basicity coagulant (PAC85) caused a significant increase of fine particles in the outflow from the sedimentation tanks, which could not be retained in the filter bed due to high surface charge and the small size of hydrolysis products. When using a coagulant of lower basicity (PAC70), it was much easier to control the dose of coagulant and to adjust it to the changing water quality.
Dia, Oumar; Drogui, Patrick; Buelna, Gerardo; Dubé, Rino; Ihsen, Ben Salah
2017-02-01
Electrocoagulation (EC) was employed to treat residual organic matter from a landfill leachate pretreated by an aerated bio-filter system. Organic matter (humic acids (HA), fulvic acids (FA) and hydrophilic compounds (Hyl)) was fractionated using DAX-8 resin in order to estimate the efficiency of EC on each fraction. Initial characterization of the bio-filtrated landfill leachate showed that humic substances (HA + FA) represented nearly 90% of TOC. The effects of current densities, type of anode (Aluminum versus iron), and treatment time on the performance of COD removal were investigated. The best COD removal performances were recorded at a current density ranging between 8.0 and 10 mA cm -2 during 20 min of treatment time. Under these conditions, 70% and 65% of COD were removed using aluminum and iron electrodes, respectively. The fractionating of organic matter after EC treatment revealed that HA was completely removed using either aluminum or iron anode. However, FA and Hyl fractions were partially removed, with the percentages varying from 57 to 60% and 37-46%, respectively. FA and Hyl removal were quite similar using either aluminum or iron anode. Likewise, a significant decrease in 254-nm absorbance was recorded (UV 254 removal of 79-80%) using either type of anode. These results proved that EC is a suitable and efficient approach for treating the residual refractory organic matter from a landfill leachate previously treated by a biological system. Copyright © 2016 Elsevier Ltd. All rights reserved.
Filter media properties of mineral fibres produced by plasma spray.
Prasauskas, Tadas; Matulevicius, Jonas; Kliucininkas, Linas; Krugly, Edvinas; Valincius, Vitas; Martuzevicius, Dainius
2016-01-01
The purpose of this study was to determine the properties of fibrous gas filtration media produced from mineral zeolite. Fibres were generated by direct current plasma spray. The paper characterizes morphology, chemical composition, geometrical structure of elementary fibres, and thermal resistance, as well as the filtration properties of fibre media. The diameter of the produced elementary fibres ranged from 0.17 to 0.90 μm and the length ranged from 0.025 to 5.1 mm. The release of fibres from the media in the air stream was noticed, but it was minimized by hot-pressing the formed fibre mats. The fibres kept their properties up to the temperature of 956°C, while further increase in temperature resulted in the filter media becoming shrunk and brittle. The filtration efficiency of the prepared filter mats ranged from 95.34% to 99.99% for aerosol particles ranging in a size between 0.03 and 10.0 μm. Unprocessed fibre media showed the highest filtration efficiency when filtering aerosol particles smaller than 0.1 µm. Hot-pressed filters were characterized by the highest quality factor values, ranging from 0.021 to 0.064 Pa(-1) (average value 0.034 Pa(-1)).
Ali, Asmaa; Ahmed, Abdelkader; Gad, Ali
2017-01-01
This study aims to investigate the ability of low cost ceramic membrane filtration in removing three common heavy metals namely; Pb 2+ , Cu 2+ , and Cd 2+ from water media. The work includes manufacturing ceramic membranes with dimensions of 15 by 15 cm and 2 cm thickness. The membranes were made from low cost materials of local clay mixed with different sawdust percentages of 0.5%, 2.0%, and 5.0%. The used clay was characterized by X-ray diffraction (XRD) and X-ray fluorescence analysis. Aqueous solutions of heavy metals were prepared in the laboratory and filtered through the ceramic membranes. The influence of the main parameters such as pH, initial driving pressure head, and concentration of heavy metals on their removal efficiency by ceramic membranes was investigated. Water samples were collected before and after the filtration process and their heavy metal concentrations were determined by chemical analysis. Moreover, a microstructural analysis using scanning electronic microscope (SEM) was performed on ceramic membranes before and after the filtration process. The chemical analysis results showed high removal efficiency up to 99% for the concerned heavy metals. SEM images approved these results by showing adsorbed metal ions on sides of the internal pores of the ceramic membranes.
Removal of trace metal contaminants from potable water by electrocoagulation
Heffron, Joe; Marhefke, Matt; Mayer, Brooke K.
2016-01-01
This study investigated the effects of four operational and environmental variables on the removal of trace metal contaminants from drinking water by electrocoagulation (EC). Removal efficiencies for five metals (arsenic, cadmium, chromium, lead and nickel) were compared under varying combinations of electrode material, post-treatment, water composition and pH. Iron electrodes out-performed aluminum electrodes in removing chromium and arsenic. At pH 6.5, aluminum electrodes were slightly more effective at removing nickel and cadmium, while at pH 8.5, iron electrodes were more effective for these metals. Regardless of electrode, cadmium and nickel removal efficiencies were higher at pH 8.5 than at pH 6.5. Post-EC treatment using membrane filtration (0.45 μm) enhanced contaminant removal for all metals but nickel. With the exception of lead, all metals exhibited poorer removal efficiencies as the ionic strength of the background electrolyte increased, particularly in the very high-solids synthetic groundwaters. Residual aluminum concentrations were lowest at pH 6.5, while iron residuals were lowest in low ionic strength waters. Both aluminum and iron residuals required post-treatment filtration to meet drinking water standards. EC with post-treatment filtration appears to effectively remove trace metal contaminants to potable water standards, but both reactor and source water parameters critically impact removal efficiency. PMID:27324564
Wang, Xinyan; Shi, Tingming; Lu, Wei; Qin, Shaoxian; Liu, Yuewei; Tao, Ying; Zhang, Hongge; Chen, Weihong
2015-01-01
The objective of this study was to investigate the aspiratory resistance, filtration penetration and their influence factors of N95 filtering-facepiece respirators used widely in China. The total of 6 brands and 21 models of N95 filtering-facepiece respirators which are certified and big sales on the market. The aspiratory resistance and filtration efficiency filter penetration were measured while air pump ran from 10 L/min to 100 L/min using differential pressure gauge and the PortaCount, respectively. The filtration penetrations for 2 of the 21 models were lower than 95%, and the qualified rate for all models was 90.47%. The filtration penetrations gradually decreased when ventilation flow of air pump increased. The negative correlation was observed between filtration penetration and ventilation flow (r(2) = 0.711, P < 0.05). The resistances of all 21 models of N95 respirators met the requirements of the national standard. The aspiratory resistance started to elevate with the increasing of ventilation flow, and a positive correlation between both (r(2) = 0.878, P < 0.05). Significant differences of filtration penetration and aspiratory resistance were observed among between different brands (P < 0.05) although no differences of filtration penetration existed among different models of one brand (P > 0.05). But the differences of the aspiratory resistance among different models of one brand were statistically significant (P < 0.05). The aspiratory resistances of all N95 filtering-facepiece respirators used in this study met the requirements of the national standard. And the qualified ratio of filtration penetration of all models was higher than 90%. The influencing factors of aspiratory resistance included materials, size and ventilation flow. And influencing factors for filtration penetration were materials and ventilation flow.
Phelps, T J; Palumbo, A V; Bischoff, B L; Miller, C J; Fagan, L A; McNeilly, M S; Judkins, R R
2008-07-01
Robust filtering techniques capable of efficiently removing particulates and biological agents from water or air suffer from plugging, poor rejuvenation, low permeance, and high backpressure. Operational characteristics of pressure-driven separations are in part controlled by the membrane pore size, charge of particulates, transmembrane pressure and the requirement for sufficient water flux to overcome fouling. With long term use filters decline in permeance due to filter-cake plugging of pores, fouling, or filter deterioration. Though metallic filter tube development at ORNL has focused almost exclusively on gas separations, a small study examined the applicability of these membranes for tangential filtering of aqueous suspensions of bacterial-sized particles. A mixture of fluorescent polystyrene microspheres ranging in size from 0.5 to 6 microm in diameter simulated microorganisms in filtration studies. Compared to a commercial filter, the ORNL 0.6 microm filter averaged approximately 10-fold greater filtration efficiency of the small particles, several-fold greater permeance after considerable use and it returned to approximately 85% of the initial flow upon backflushing versus 30% for the commercial filter. After filtering several liters of the particle-containing suspension, the ORNL composite filter still exhibited greater than 50% of its initial permeance while the commercial filter had decreased to less than 20%. When considering a greater filtration efficiency, greater permeance per unit mass, greater percentage of rejuvenation upon backflushing (up to 3-fold), and likely greater performance with extended use, the ORNL 0.6 microm filters can potentially outperform the commercial filter by factors of 100-1,000 fold.
IMPROVED TEST METHODS FOR ELECTRONIC AIR CLEANERS
The objective of this project was to develop a fractional filtration efficiency test protocol for residential electrostatic precipitators (ESPs) that avoids the limitations of the ASHRAE 52.2 method. Specifically, the objectives were to a) determine the change in efficiency that ...
Soares, Abel Esteves; Maes, Michael; Godeny, Paula; Matsumoto, Andressa Keiko; Barbosa, Décio Sabbatini; da Silva, Taysa Antonia F; Souza, Flávio Henrique M O; Delfino, Vinicius Daher Alvares
2017-12-15
Vitamin D has anti-inflammatory, anti-fibrotic effect, and may block the intrarenal renin-angiotensin system. Adequate vitamin D levels in conjunction with the use of Angiotensin-converting Enzyme Inhibitors/Angiotensin Receptor Blockers may help to slow down chronic kidney disease progression. To study a possible beneficial effect of vitamin D supplementation in chronic kidney disease patients using angiotensin-converting enzyme inhibitors/angiotensin receptor blockers on chronic kidney disease progression we performed a clinical study involving vitamin D supplementation in patients with deficiency of this vitamin. This study was conducted in two chronic kidney disease clinics in the city of Londrina, Brazil, from October 2010 to December 2012. It was involved stage 3 and 4 chronic kidney disease (estimated glomerular filtration rate between 60 and 15mL/min/1.73m 2 ) patients with and without vitamin D deficiency. The patients ingested six-month cholecalciferol 50,000IU oral supplementation to chronic kidney disease patients with vitamin D deficiency. We hypothesize changes in estimated glomerular filtration rate over study period. Our data demonstrate reservation of estimated glomerular filtration with cholecalciferol supplementation to chronic kidney disease patients taking angiotensin-converting enzyme inhibitors/angiotensin receptor blockers. The combination treatment of angiotensin converting enzyme inhibitors/angiotensin receptor blockers with cholecalciferol prevents the decline in estimated glomerular filtration in patients with chronic kidney disease following treatment with angiotensin-converting enzyme inhibitors/angiotensin receptor blockers and may represent a valid approach to reduce renal disease progression in chronic kidney disease patients with vitamin D deficiency. This result needs confirmation in prospective controlled clinical trials. Copyright © 2017. Published by Elsevier Inc.
Townsend, Raymond R; Anderson, Amanda Hyre; Chirinos, Julio A; Feldman, Harold I; Grunwald, Juan E; Nessel, Lisa; Roy, Jason; Weir, Matthew R; Wright, Jackson T; Bansal, Nisha; Hsu, Chi-Yuan
2018-06-01
Patients with chronic kidney diseases (CKDs) are at risk for further loss of kidney function and death, which occur despite reasonable blood pressure treatment. To determine whether arterial stiffness influences CKD progression and death, independent of blood pressure, we conducted a prospective cohort study of CKD patients enrolled in the CRIC study (Chronic Renal Insufficiency Cohort). Using carotid-femoral pulse wave velocity (PWV), we examined the relationship between PWV and end-stage kidney disease (ESRD), ESRD or halving of estimated glomerular filtration rate, or death from any cause. The 2795 participants we enrolled had a mean age of 60 years, 56.4% were men, 47.3% had diabetes mellitus, and the average estimated glomerular filtration rate at entry was 44.4 mL/min per 1.73 m 2 During follow-up, there were 504 ESRD events, 628 ESRD or halving of estimated glomerular filtration rate events, and 394 deaths. Patients with the highest tertile of PWV (>10.3 m/s) were at higher risk for ESRD (hazard ratio [95% confidence interval], 1.37 [1.05-1.80]), ESRD or 50% decline in estimated glomerular filtration rate (hazard ratio [95% confidence interval], 1.25 [0.98-1.58]), or death (hazard ratio [95% confidence interval], 1.72 [1.24-2.38]). PWV is a significant predictor of CKD progression and death in people with impaired kidney function. Incorporation of PWV measurements may help define better the risks for these important health outcomes in patients with CKDs. Interventions that reduce aortic stiffness deserve study in people with CKD. © 2018 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Roy, Sukumar; Ghosh, Subrata; Bhowmick, Niranjan
2018-06-01
A mechanism to remove the Pseudomonas bacteria from contaminated water by using textile fibrous media has been proposed in this article. The attachment of Pseudomonas bacteria on nylon fibrous media was studied in laboratory column experiment. A systematic study was carried out to investigate the attachment of bacteria on the fibrous material as a function of fiber orientation to the direction of the liquid flow. Three types of textiles media with different orientation fiber were selected for the experiment (i.e. 0°, 45° and 90°). It was found that the bacteria removal efficiency was comparatively higher at 90° orientation as compared to that of 45° and 0° orientation of fibrous media, suggesting that the removal efficiency of bacteria (1 - Fp) was depended on fiber orientation. The removal trends were explained on the basis of colloidal filtration theory. This is due to the higher single collector contact efficiency and attachment/collision efficiency as observed from the experimental data of removal efficiency.
NASA Astrophysics Data System (ADS)
Roy, Sukumar; Ghosh, Subrata; Bhowmick, Niranjan
2018-05-01
A mechanism to remove the Pseudomonas bacteria from contaminated water by using textile fibrous media has been proposed in this article. The attachment of Pseudomonas bacteria on nylon fibrous media was studied in laboratory column experiment. A systematic study was carried out to investigate the attachment of bacteria on the fibrous material as a function of fiber orientation to the direction of the liquid flow. Three types of textiles media with different orientation fiber were selected for the experiment (i.e. 0°, 45° and 90°). It was found that the bacteria removal efficiency was comparatively higher at 90° orientation as compared to that of 45° and 0° orientation of fibrous media, suggesting that the removal efficiency of bacteria (1 - Fp) was depended on fiber orientation. The removal trends were explained on the basis of colloidal filtration theory. This is due to the higher single collector contact efficiency and attachment/collision efficiency as observed from the experimental data of removal efficiency.
Activities of Aureobasidium pullulans cell filtrates against Monilinia laxa of peaches.
Di Francesco, Alessandra; Roberti, Roberta; Martini, Camilla; Baraldi, Elena; Mari, Marta
2015-12-01
The Aureobasidium pullulans L1 and L8 strains are known as efficient biocontrol agents against several postharvest fungal pathogens. In order to better understand the mechanism of action underneath the antifungal activity of L1 and L8 strains, yeast cell filtrates grown at different times were evaluated in vivo against Monilinia laxa on peach. Lesion diameters on peach fruit were reduced by L1 and L8 culture filtrates of 42.5% and 67% respectively. The ability of these filtrates to inhibit M. laxa conidia germination and germ tube elongation was studied by in vitro assays. The results showed a 70% reduction of conidia germination for both strains while for germ tube elongation, it was 52% and 41% for L1 and L8 culture filtrates respectively. Finally, the activity of cell wall hydrolytic enzymes such as chitinase and glucanase in cell filtrates was analysed and the expression of genes encoding these activities was quantified during yeast growth. From 24h onward, both culture filtrates contained β,1-3,glucanase and. chitinase activities, the most pronounced of which was N-β-acetylglucosaminidase. Gene expression level encoding for these enzymes in L1 and L8 varied according to the strain. These results indicate that L1 and L8 strains culture filtrates retain the yeast antagonistic activity and suggest that the production of hydrolytic enzymes plays an important role in this activity. Copyright © 2015 Elsevier GmbH. All rights reserved.
Eco-efficient one-pot synthesis of quinazoline-2,4(1H,3H)-diones at room temperature in water.
Tian, Xin-Chuan; Huang, Xing; Wang, Dan; Gao, Feng
2014-01-01
An efficient one-pot synthesis of quinazoline-2,4(1H,3H)-diones was developed. First, the reactions of anthranilic acid derivatives with potassium cyanate afforded the corresponding urea derivatives. Then, cyclization of the urea derivatives with NaOH afforded the monosodium salts of benzoylene urea. Finally, HCl treatment afforded the desired products in near-quantitative yields. This is an eco-efficient method because all the reactions were carried out in water, and the desired products were obtained simply by filtration. The aqueous filtrate was the only waste generated from the reaction. We scaled up the reaction to 1 kg starting material, thus establishing an alternative approach for the green synthesis of quinazoline-2,4(1H,3H)-diones in the chemical and pharmaceutical industries.
Abebe, Lydia S; Su, Yi-Hsuan; Guerrant, Richard L; Swami, Nathan S; Smith, James A
2015-11-03
Ceramic water filters (CWFs) impregnated with silver nanoparticles are a means of household-level water treatment. CWFs remove/deactivate microbial pathogens by employing two mechanisms: metallic disinfection and physical filtration. Herein we report on the independent effects of silver salt and nanoparticles on Cryptosporidium parvum and the removal of C. parvum by physical filtration in porous ceramic filter media. Using a murine (mouse) model, we observed that treatment of oocysts with silver nitrate and proteinate-capped silver nanoparticles resulted in decreased infection relative to untreated oocysts. Microscopy and excystation experiments were conducted to support the disinfection investigation. Heat and proteinate-capped silver-nanoparticle treatment of oocysts resulted in morphological modifications and decreased excystation rates of sporozoites. Subsequently, disk-shaped ceramic filters were produced to investigate the transport of C. parvum. Two factors were varied: sawdust size and clay-to-sawdust ratio. Five disks were prepared with combinations of 10, 16, and 20 mesh sawdust and sawdust percentage that ranged from 9 to 11%. C. parvum removal efficiencies ranged from 1.5 log (96.4%) to 2.1 log (99.2%). The 16-mesh/10% sawdust had the greatest mean reduction of 2.1-log (99.2%), though there was no statistically significant difference in removal efficiency. Based on our findings, physical filtration and silver nanoparticle disinfection likely contribute to treatment of C. parvum for silver impregnated ceramic water filters, although the contribution of physical filtration is likely greater than silver disinfection.
Origins of saline fluids at convergent margins
NASA Astrophysics Data System (ADS)
Martin, Jonathan B.; Kastner, Miriam; Egeberg, Per Kr.
The compositions of pore and venting fluids at convergent margins differ from seawater values, reflecting mixing and diagenesis. Most significantly, the concentration of Cl-, assumed to be a conservative ion, differs from its seawater value. Chloride concentrations could be elevated by four processes, although two, the formation of gas hydrate and ion filtration by clay membranes, are insignificant in forming saline fluids at convergent margins. During the formation of gas hydrate, the resulting Cl--rich fluids, estimated to contain an average excess of ˜140 mM Cl- over seawater value, probably would be flushed from the sediment when the pore fluids vent to seawater. Ion filtration by clay membranes requires compaction pressures typical of >2 km burial depths. Even at these depths, the efficiency of ion filtration will be negligible because (1) fluids will flow through fractures, thereby bypassing clay membranes, (2) concentrations of clay minerals are diluted by other phases, and (3) during burial, smectite converts to illite, which has little capacity for ion filtration. A third process, mixing with subaerially evaporated seawater, elevates Cl- concentrations to 1043 mM in forearc basins along the Peru margin. Evaporation of seawater, however, will be important only in limited geographic regions that are characterized by enclosed basins, arid climates, and permeable sediments. At the New Hebrides and Izu-Bonin margins, Cl- concentrations are elevated to a maximum of 1241 mM. The process responsible for this increase is the alteration of volcanic ash to hydrous clay and zeolite minerals. Mass balance calculations, based on the decrease in δ18O values to -9.5‰ (SMOW), suggest that the Cl- concentrations could increase solely from the formation of smectite in a closed system. The diagenesis of volcanic ash also alters the concentrations of most dissolved species in addition to Cl-. Depending on the volume of this altered fluid, it could influence seawater chemistry when vented from the sediment.
Under EPA's Environmental Technology Verification Program, Research Triangle Institute (RTI) will operate the Air Pollution Control Technology Center to verify the filtration efficiency and bioaerosol inactivation efficiency of heating, ventilation and air conditioning air cleane...
Rotating Reverse Osmosis for Wastewater Reuse
NASA Technical Reports Server (NTRS)
Lueptow, Richard M.; Yoon, Yeomin; Pederson, Cynthia
2004-01-01
Membrane filtration such as Reverse Osmosis (RO) removes ions, proteins, and organic chemicals which are generally very difficult to remove using conventional treatment. Moreover, membrane is an absolute filtration method, so its treatment efficiency and performance are stable and predictable. We are currently working on the development of rotating RO membrane system. Dynamic rotating membrane filtration, which can produce a high shear rate, may be helpful to obtain high rejection of organic pollutants.The goal of our current work is to improve the flux of the device by increasing pressure by a factor of 3 to 4. In addition, the rejections for a wider variety of inorganic and organic compounds typically found in space mission wastewater are measured.
Pernin, P.; Pélandakis, M.; Rouby, Y.; Faure, A.; Siclet, F.
1998-01-01
Detection of pathogenic Naegleria fowleri in environmental water samples, which is necessary for the prevention of primary amoebic meningoencephalitis, generally requires concentrating the samples. Two concentration techniques, filtration and centrifugation, were used to study the recovery of N. fowleri, in vegetative or cystic form, that had been mixed with the two other thermotolerant Naegleria species, N. lovaniensis and N. australiensis. Counting of amoebae was performed by the most probable number method on 10 water replicates of 100 ml and 10 ml each. With both concentration methods, recovery was better for cysts than for trophozoites (53% ± 21% versus 5% ± 5% by filtration and 57% ± 25% versus 22% ± 5% by centrifugation). The recovery of Naegleria trophozoites by filtration was very low, and centrifugation was significantly better than filtration in recovery of Naegleria trophozoites (22% ± 5% versus 5% ± 5%; P < 0.001). For cysts, however, filtration appeared as efficient as centrifugation, with equivalent values for recovery (53% ± 21% versus 57% ± 25%; P > 0.7). Although the recovery of cysts of N. fowleri obtained by filtration (51% ± 24%) appeared higher than that by centrifugation (36% ± 23%), the difference was not significant (P > 0.1). Both concentration methods have highly variable recovery rates, making accurate quantification of low concentrations (<100/liter) of N. fowleri in the environment difficult. PMID:9501435
Kwiatkowska, Ewa; Domański, Leszek; Bober, Joanna; Safranow, Krzysztof; Pawlik, Andrzej; Ciechanowski, Kazimierz; Wiśniewska, Magda; Kędzierska, Karolina
2017-08-01
Organs from brain-dead donors are the main source of allografts for transplant. Comparisons between living-donor and brain-dead donor kidneys show that the latter are more likely to demonstrate delayed graft function and lower long-term survival. This study aimed to assess the effects of various clinical and biochemical factors of donors on early- and long-term renal function after transplant. We analyzed data from kidney recipients treated between 2006 and 2008 who received organs from brain-dead donors. Data from 54 donors and 89 recipients were analyzed. No relation was observed between donor sodium concentration and the presence of delayed graft function. Donor height was positively correlated with creatinine clearance in recipients in the 1 to 3 months after renal transplant. Donor diastolic blood pressure was negatively correlated with estimated glomerular filtration rate throughout the observation period. Donor age was negatively correlated with the allograft recipient's estimated glomerular filtration rate throughout 4 years of observation. Donor estimated glomerular filtration rate was positively correlated with that of the recipient throughout 3 years of observation. The results of this study indicate that various factors associated with allograft donors may influence graft function.
Ravn, Bo; Prowle, John R; Mårtensson, Johan; Martling, Claes-Roland; Bell, Max
2017-09-01
Renal outcomes after critical illness are seldom assessed despite strong correlation between chronic kidney disease and survival. Outside hospital, renal dysfunction is more strongly associated with mortality when assessed by serum cystatin C than by creatinine. The relationship between creatinine and longer term mortality might be particularly weak in survivors of critical illness. Retrospective observational cohort study. In 3,077 adult ICU survivors, we compared ICU discharge cystatin C and creatinine and their association with 1-year mortality. Exclusions were death within 72 hours of ICU discharge, ICU stay less than 24 hours, and end-stage renal disease. None. During ICU admission, serum cystatin C and creatinine diverged, so that by ICU discharge, almost twice as many patients had glomerular filtration rate less than 60 mL/min/1.73 m when estimated from cystatin C compared with glomerular filtration rate estimated from creatinine, 44% versus 26%. In 743 patients without acute kidney injury, where ICU discharge renal function should reflect ongoing baseline, discharge glomerular filtration rate estimated from creatinine consistently overestimated follow-up glomerular filtration rate estimated from creatinine, whereas ICU discharge glomerular filtration rate estimated from cystatin C well matched follow-up chronic kidney disease status. By 1 year, 535 (17.4%) had died. In survival analysis adjusted for age, sex, and comorbidity, cystatin C was near-linearly associated with increased mortality, hazard ratio equals to 1.78 (95% CI, 1.46-2.18), 75th versus 25th centile. Conversely, creatinine demonstrated a J-shaped relationship with mortality, so that in the majority of patients, there was no significant association with survival, hazard ratio equals to 1.03 (0.87-1.2), 75th versus 25th centile. After adjustment for both creatinine and cystatin C levels, higher discharge creatinine was then associated with lower long-term mortality. In contrast to creatinine, cystatin C consistently associated with long-term mortality, identifying patients at both high and low risk, and better correlated with follow-up renal function. Conversely, lower creatinine relative to cystatin C appeared to confer adverse prognosis, confounding creatinine interpretation in isolation. Cystatin C warrants further investigation as a more meaningful measure of renal function after critical illness.
NASA Astrophysics Data System (ADS)
Tsai, Candace S.-J.; Echevarría-Vega, Manuel E.; Sotiriou, Georgios A.; Santeufemio, Christopher; Schmidt, Daniel; Demokritou, Philip; Ellenbecker, Michael
2012-05-01
Applying engineering controls to airborne engineered nanoparticles (ENPs) is critical to prevent environmental releases and worker exposure. This study evaluated the effectiveness of two air sampling and six air cleaning fabric filters at collecting ENPs using industrially relevant flame-made engineered nanoparticles generated using a versatile engineered nanomaterial generation system (VENGES), recently designed and constructed at Harvard University. VENGES has the ability to generate metal and metal oxide exposure atmospheres while controlling important particle properties such as primary particle size, aerosol size distribution, and agglomeration state. For this study, amorphous SiO2 ENPs with a 15.4 nm primary particle size were generated and diluted with HEPA-filtered air. The aerosol was passed through the filter samples at two different filtration face velocities (2.3 and 3.5 m/min). Particle concentrations as a function of particle size were measured upstream and downstream of the filters using a specially designed filter test system to evaluate filtration efficiency. Real time instruments (FMPS and APS) were used to measure particle concentration for diameters from 5 to 20,000 nm. Membrane-coated fabric filters were found to have enhanced nanoparticle collection efficiency by 20-46 % points compared to non-coated fabric and could provide collection efficiency above 95 %.
Biofiltration of airborne VOCs with green wall systems-Microbial and chemical dynamics.
Mikkonen, A; Li, T; Vesala, M; Saarenheimo, J; Ahonen, V; Kärenlampi, S; Blande, J D; Tiirola, M; Tervahauta, A
2018-05-06
Botanical air filtration is a promising technology for reducing indoor air contaminants, but the underlying mechanisms need better understanding. Here, we made a set of chamber fumigation experiments of up to 16 weeks of duration, to study the filtration efficiencies for seven volatile organic compounds (VOCs; decane, toluene, 2-ethylhexanol, α-pinene, octane, benzene, and xylene) and to monitor microbial dynamics in simulated green wall systems. Biofiltration functioned on sub-ppm VOC levels without concentration-dependence. Airflow through the growth medium was needed for efficient removal of chemically diverse VOCs, and the use of optimized commercial growth medium further improved the efficiency compared with soil and Leca granules. Experimental green wall simulations using these components were immediately effective, indicating that initial VOC removal was largely abiotic. Golden pothos plants had a small additional positive impact on VOC filtration and bacterial diversity in the green wall system. Proteobacteria dominated the microbiota of rhizosphere and irrigation water. Airborne VOCs shaped the microbial communities, enriching potential VOC-utilizing bacteria (especially Nevskiaceae and Patulibacteraceae) in the irrigation water, where much of the VOC degradation capacity of the biofiltration systems resided. These results clearly show the benefits of active air circulation and optimized growth media in modern green wall systems. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Echevarría-Vega, Manuel E.; Sotiriou, Georgios A.; Santeufemio, Christopher; Schmidt, Daniel; Demokritou, Philip; Ellenbecker, Michael
2013-01-01
Applying engineering controls to airborne engineered nanoparticles (ENPs) is critical to prevent environmental releases and worker exposure. This study evaluated the effectiveness of two air sampling and six air cleaning fabric filters at collecting ENPs using industrially relevant flame-made engineered nanoparticles generated using a versatile engineered nanomaterial generation system (VENGES), recently designed and constructed at Harvard University. VENGES has the ability to generate metal and metal oxide exposure atmospheres while controlling important particle properties such as primary particle size, aerosol size distribution, and agglomeration state. For this study, amorphous SiO2 ENPs with a 15.4 nm primary particle size were generated and diluted with HEPA-filtered air. The aerosol was passed through the filter samples at two different filtration face velocities (2.3 and 3.5 m/min). Particle concentrations as a function of particle size were measured upstream and downstream of the filters using a specially designed filter test system to evaluate filtration efficiency. Real time instruments (FMPS and APS) were used to measure particle concentration for diameters from 5 to 20,000 nm. Membrane-coated fabric filters were found to have enhanced nanoparticle collection efficiency by 20–46 % points compared to non-coated fabric and could provide collection efficiency above 95 %. PMID:23412707
Bulanek, Boris; Hulka, Jiri; Jilek, Karel; Stekl, Ivan
2015-06-01
In this article, a portable device was presented for continual measuring of equilibrium equivalent concentration (EEC) of (222)Rn based on the Timepix detector with 300-µm-thick active layer. In order to have a portable device, a filtration head was developed for collecting short-lived radon progenies attached on aerosols. The short-lived progenies are estimated from analysing alphas from decay of (218,214)Po from Millipore filter after termination of filtration. Comparison with beta measurement was done as well. The dependence of EEC on an air flow and filtration time was studied. The low-level detection limit for EEC was estimated from the last 10 min of 3-h decay measurement and was found in the range of 40-70 Bq m(-3). EEC was measured in National Radiation Protection Institute radon chamber, and results were compared with the commercial detector Fritra4. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ding, Yanfeng; Stidham, Rhesa; Bumeister, Ron; Trevino, Isaac; Winters, Ali; Sprouse, Marc; Ding, Min; Ferguson, Deborah A.; Meyer, Colin J.; Wigley, W. Christian; Ma, Rong
2012-01-01
Bardoxolone methyl, a synthetic triterpenoid, improves the estimated glomerular filtration rate (GFR) in patients with chornic kidney disease and type 2 diabetes. Since the contractile activity of mesangial cells may influence glomerular filtration, we evaluated the effect of the synthetic triterpenoid RTA405 with structural similarity to bardoxolone methyl, on GFR in rats and on mesangial cell contractility in freshly isolated glomeruli. In rats, RTA 405 increased basal GFR, assessed by inulin clearance, and attenuated the angiotensin II-induced decline in GFR. RTA 405 increased the filtration fraction, but did not affect arterial blood pressure or renal plasma flow. Glomeruli from RTA 405-treated rats were resistant to angiotensin II-induced volume reduction ex vivo. In cultured mesangial cells, angiotensin II-stimulated contraction was attenuated by RTA 405, in a dose- and time-dependent fashion. Further, Nrf2 targeted gene transcription (regulates antioxidant, anti-inflammatory, and cytoprotective responses) in mesangial cells was associated with decreased basal and reduced angiotensin II-stimulated hydrogen peroxide and calcium ion levels. These mechanisms contribute to the GFR increase that occurs following treatment with RTA 405 in rats and may underlie the effect of bardoxolone methyl on the estimated GFR in patients. PMID:23235569
Ding, Yanfeng; Stidham, Rhesa D; Bumeister, Ron; Trevino, Isaac; Winters, Ali; Sprouse, Marc; Ding, Min; Ferguson, Deborah A; Meyer, Colin J; Wigley, W Christian; Ma, Rong
2013-05-01
Bardoxolone methyl, a synthetic triterpenoid, improves the estimated glomerular filtration rate (GFR) in patients with chronic kidney disease and type 2 diabetes. Since the contractile activity of mesangial cells may influence glomerular filtration, we evaluated the effect of the synthetic triterpenoid RTA 405, with structural similarity to bardoxolone methyl, on GFR in rats and on mesangial cell contractility in freshly isolated glomeruli. In rats, RTA 405 increased basal GFR, assessed by inulin clearance, and attenuated the angiotensin II-induced decline in GFR. RTA 405 increased the filtration fraction, but did not affect arterial blood pressure or renal plasma flow. Glomeruli from RTA 405-treated rats were resistant to angiotensin II-induced volume reduction ex vivo. In cultured mesangial cells, angiotensin II-stimulated contraction was attenuated by RTA 405, in a dose- and time-dependent fashion. Further, Nrf2-targeted gene transcription (regulates antioxidant, anti-inflammatory, and cytoprotective responses) in mesangial cells was associated with decreased basal and reduced angiotensin II-stimulated hydrogen peroxide and calcium ion levels. These mechanisms contribute to the GFR increase that occurs following treatment with RTA 405 in rats and may underlie the effect of bardoxolone methyl on the estimated GFR in patients.
Ruilope, Luis M; Zanchetti, Alberto; Julius, Stevo; McInnes, Gordon T; Segura, Julian; Stolt, Pelle; Hua, Tsushung A; Weber, Michael A; Jamerson, Ken
2007-07-01
Reduced renal function is predictive of poor cardiovascular outcomes but the predictive value of different measures of renal function is uncertain. We compared the value of estimated creatinine clearance, using the Cockcroft-Gault formula, with that of estimated glomerular filtration rate (GFR), using the Modification of Diet in Renal Disease (MDRD) formula, as predictors of cardiovascular outcome in 15 245 high-risk hypertensive participants in the Valsartan Antihypertensive Long-term Use Evaluation (VALUE) trial. For the primary end-point, the three secondary end-points and for all-cause death, outcomes were compared for individuals with baseline estimated creatinine clearance and estimated GFR < 60 ml/min and > or = 60 ml/min using hazard ratios and 95% confidence intervals. Coronary heart disease, left ventricular hypertrophy, age, sex and treatment effects were included as covariates in the model. For each end-point considered, the risk in individuals with poor renal function at baseline was greater than in those with better renal function. Estimated creatinine clearance (Cockcroft-Gault) was significantly predictive only of all-cause death [hazard ratio = 1.223, 95% confidence interval (CI) = 1.076-1.390; P = 0.0021] whereas estimated GFR was predictive of all outcomes except stroke. Hazard ratios (95% CIs) for estimated GFR were: primary cardiac end-point, 1.497 (1.332-1.682), P < 0.0001; myocardial infarction, 1.501 (1.254-1.796), P < 0.0001; congestive heart failure, 1.699 (1.435-2.013), P < 0.0001; stroke, 1.152 (0.952-1.394) P = 0.1452; and all-cause death, 1.231 (1.098-1.380), P = 0.0004. These results indicate that estimated glomerular filtration rate calculated with the MDRD formula is more informative than estimated creatinine clearance (Cockcroft-Gault) in the prediction of cardiovascular outcomes.
Characterization of microsieves recovery efficiency in isolation of circulating tumor cells
NASA Astrophysics Data System (ADS)
Osuchowska, Paulina Natalia; Sarzyński, Antoni; Strzelec, Marek; Bogdanowicz, Zdzisław; Marczak, Jan; Łapiński, Mariusz Piotr; Trafny, ElŻbieta Anna
2016-12-01
Isolation of circulating tumor cells (CTCs) from the blood is important in the diagnosis of malignant tumors and for monitoring therapeutic responses. The two main problems to be solved are extremely low CTCs numbers in the blood (average 1-10 CTC per 10 ml of whole blood) and the absence of one particular phenotype or genotype, which would allow for precise identification. Isolation of CTCs can be based on physical characteristics, e.g. the size of the cells (ISET, Isolation by Size of Epithelial Tumor cells) or the biological properties of these cells (the expression of specific proteins on their surface). In the IOE WAT the copper alloy microsieves with a pore diameter of 10.85 +/- 0.89 μm designed for cell isolation by ISET method were produced. The microsieves with 100 000 pores with a 50 μm interval was made using precise, percussion laser drilling. The performance microsieves filtration was determined using fluorescent beads with three dimensions: 4 μm, 10 μm and 15 μm. Furthermore, the suspensions of cells lines from different types of tumor were used in the process of filtration. The efficiency of the cells filtration process was affected by lack of biocompatibility of the material used for the microsieves production as well as the roughness and porosity of the microsieves surface. Moreover, the diameter of the pores and the course of the filtration process were also significant.
Frohnert, Anne; Kreißel, Katja; Lipp, Pia; Dizer, Halim; Hambsch, Beate; Szewzyk, Regine; Selinka, Hans-Christoph
2015-03-19
Experiments to determine the removal of viruses in different types of water (surface water from two reservoirs for drinking water treatment, treated groundwater and groundwater contaminated with either 5 or 30 % of wastewater) by ultrafiltration were performed with a semi-technical ultrafiltration unit. Concentrations of human adenoviruses (HAdVs), murine norovirus (MNV), and the bacteriophages MS2, ΦX174 and PRD1 were measured in the feed water and the filtrate, and log removal values were calculated. Bacteria added to the feed water were not detected in the filtrates. In contrast, in most cases viruses and bacteriophages were still present in the filtrates: log removal values were in the range of 1.4-6.3 depending on virus sizes and water qualities. Best removals were observed with bacteriophage PRD1 and HAdVs, followed by MNV and phages MS2 and ΦX174. Virus size, however, was not the only criterion for efficient removal. In diluted wastewater as compared to drinking water and uncontaminated environmental waters, virus removal was clearly higher for all viruses, most likely due to higher membrane fouling. For quality assessment purposes of membrane filtration efficiencies with regard to the elimination of human viruses the small bacteriophages MS2 and ΦX174 should be used as conservative viral indicators.
Shabtai, Itamar A; Mishael, Yael G
2016-08-02
Hybrid polycation-clay composites, based on methylated poly vinylpyridinium, were optimized as sorbents for secondary effluent organic matter (EfOM) including emerging micropollutants. Composite structure was tuned by solution ionic strength and characterized by zeta potential, FTIR, X-ray diffraction, and thermal gravimetric analyses. An increase in ionic strength induced a transition from a train to a loops and tails configuration, accompanied by greater polycation adsorption. Composite charge reversal (zeta potential -18 to 45 mV) increased the adsorption of EfOM and humic acid (HA), moderately and sharply, respectively, suggesting electrostatic and also nonspecific interactions with EfOM. Filtration of EfOM by columns of positively charged composites was superior to that of granular activated carbon (GAC). The overall removal of EfOM was most efficient by the composite with a train configuration. Whereas a composite with a loops and tails configuration was beneficial for the removal of the anionic micropollutants diclofenac, gemfibrozil and ibuprofen from EfOM. These new findings suggest that the loops and tails may offer unique binding sites for small micropollutants which are overseen by the bulk EfOM. Furthermore, they may explain our previous observations that in the presence of dissolved organic matter, micropollutant filtration by GAC columns was reduced, while their filtration by composite columns remained high.
Zhang, Shichao; Liu, Hui; Zuo, Fenglei; Yin, Xia; Yu, Jianyong; Ding, Bin
2017-03-01
The filtration capacity of fibrous media for airborne particles is restricted by their thick diameter, low porosity, and limited frontal area. The ability to solve this problem would have broad technological implications for various air filtration applications; despite many past efforts, it remains a great challenge to achieve. Herein, a facile and scalable strategy to fabricate the ripple-like polyamide-6 nanofiber/nets (PA-6 NF/N) air filter via combining electrospinning/netting technique with receiving substrate design is demonstrated. This proposed approach allows the scaffold filaments to orderly embed into 2D PA-6 nanonets layer with Steiner-tree structures and nanoscale diameter of ≈20 nm, resulting in the ripple-like membrane with extremely small pore size, highly porous structure, and hugely extended frontal surface, by facilely adjusting its pleat span and pleat pitch. These unique structural advantages enable the ripple-like PA-6 NF/N filter to filtrate the ultrafine particles with high removal efficiency of 99.996%, low air resistance of 95 Pa, and robust quality factor of >0.11 Pa -1 ; using its superlight weight of 0.9 g m -2 and physical sieving manner. This approach has the potentialities to give rise to a novel generation of filter media displaying enhanced filtration capacity for various applications thanks to their nanoscale features and designed macrostructures. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Magnetically Enhanced Solid-Liquid Separation
NASA Astrophysics Data System (ADS)
Rey, C. M.; Keller, K.; Fuchs, B.
2005-07-01
DuPont is developing an entirely new method of solid-liquid filtration involving the use of magnetic fields and magnetic field gradients. The new hybrid process, entitled Magnetically Enhanced Solid-Liquid Separation (MESLS), is designed to improve the de-watering kinetics and reduce the residual moisture content of solid particulates mechanically separated from liquid slurries. Gravitation, pressure, temperature, centrifugation, and fluid dynamics have dictated traditional solid-liquid separation for the past 50 years. The introduction of an external field (i.e. the magnetic field) offers the promise to manipulate particle behavior in an entirely new manner, which leads to increased process efficiency. Traditional solid-liquid separation typically consists of two primary steps. The first is a mechanical step in which the solid particulate is separated from the liquid using e.g. gas pressure through a filter membrane, centrifugation, etc. The second step is a thermal drying process, which is required due to imperfect mechanical separation. The thermal drying process is over 100-200 times less energy efficient than the mechanical step. Since enormous volumes of materials are processed each year, more efficient mechanical solid-liquid separations can be leveraged into dramatic reductions in overall energy consumption by reducing downstream drying requirements have a tremendous impact on energy consumption. Using DuPont's MESLS process, initial test results showed four very important effects of the magnetic field on the solid-liquid filtration process: 1) reduction of the time to reach gas breakthrough, 2) less loss of solid into the filtrate, 3) reduction of the (solids) residual moisture content, and 4) acceleration of the de-watering kinetics. These test results and their potential impact on future commercial solid-liquid filtration is discussed. New applications can be found in mining, chemical and bioprocesses.
Particle effects on ultraviolet disinfection of coliform bacteria in recycled water.
Jolis, D; Lam, C; Pitt, P
2001-01-01
Pilot- and bench-scale coliform inactivation tests with UV irradiation were used to show how suspended solids remaining in filtered secondary effluent affect the efficiency of the UV disinfection process. Observed kinetic inactivation rates decreased with increasing suspended particle sizes of 7 microm or larger present in tertiary effluent. First-order inactivation rates estimated from collimated beam dose-response curves for discrete ranges of UV doses were substantially different, which should caution researchers not to compare inactivation data obtained with largely dissimilar UV doses or suspended particle distributions. A dose of approximately 800 J/m2 was identified as the minimum dose that will consistently meet the California wastewater reclamation coliform criterion when applied to in-line filtration effluent.
The Influence of Grain Refiners on the Efficiency of Ceramic Foam Filters
NASA Astrophysics Data System (ADS)
Towsey, Nicholas; Schneider, Wolfgang; Krug, Hans-Peter; Hardman, Angela; Keegan, Neil J.
An extensive program of work has been carried out to evaluate the efficiency of ceramic foam filters under carefully controlled conditions. Work reported at previous TMS meetings showed that in the absence of grain refiners, ceramic foam filters have the capacity for high filtration efficiency and consistent, reliable performance. The current phase of the investigation focuses on the impact grain refiner additions have on filter performance. The high filtration efficiencies obtained using 50 or 80ppi CFF's in the absence of grain refiners diminish when Al-3%Ti-1%B grain refiners are added. This, together with the impact of incoming inclusion loading on filter performance and the level of grain refiner addition are considered in detail. The new generation Al-3%Ti-0.15%C grain refiner has also been included. At typical addition levels (1kg/tonne) the effect on filter efficiency is similar to that for TiB2based grain refiners. The work was again conducted on a production scale using AA1050 alloy. Metal quality was determined using LiMCA and PoDFA. Spent filters were also analysed.
Filter Media Tests Under Simulated Martian Atmospheric Conditions
NASA Technical Reports Server (NTRS)
Agui, Juan H.
2016-01-01
Human exploration of Mars will require the optimal utilization of planetary resources. One of its abundant resources is the Martian atmosphere that can be harvested through filtration and chemical processes that purify and separate it into its gaseous and elemental constituents. Effective filtration needs to be part of the suite of resource utilization technologies. A unique testing platform is being used which provides the relevant operational and instrumental capabilities to test articles under the proper simulated Martian conditions. A series of tests were conducted to assess the performance of filter media. Light sheet imaging of the particle flow provided a means of detecting and quantifying particle concentrations to determine capturing efficiencies. The media's efficiency was also evaluated by gravimetric means through a by-layer filter media configuration. These tests will help to establish techniques and methods for measuring capturing efficiency and arrestance of conventional fibrous filter media. This paper will describe initial test results on different filter media.
Evaluation of various harvesting methods for high-density microalgae, Aurantiochytrium sp. KRS101.
Kim, Kyochan; Shin, Heewon; Moon, Myounghoon; Ryu, Byung-Gon; Han, Jong-In; Yang, Ji-Won; Chang, Yong Keun
2015-12-01
Five technologies, coagulation, electro-flotation (EF), electro-coagulation-flotation (ECF), centrifugation, and membrane filtration, were systematically assessed for their adequacy of harvesting Aurantiochytrium sp. KRS101, a heterotrophic microalgal species that has much higher biomass concentration than photoautotrophic species. Coagulation, EF, and ECF were found to have limited efficiency. Centrifugation was overly powerful to susceptible cells like Aurantiochytrium sp. KRS101, inducing cell rupture and consequently biomass loss of over 13%. Membrane filtration, in particular equipped with an anti-fouling turbulence generator, turned out to be best suited: nearly 100% of harvesting efficiency and low water content in harvested biomass were achieved. With rotation rate increased, high permeate fluxes could be attained even with extremely concentrated biomass: e.g., 219.0 and 135.0 L/m(2)/h at 150.0 and 203.0 g/L, respectively. Dynamic filtration appears to be indeed a suitable means especially to obtain highly concentrated biomass that have no need of dewatering and can be directly processed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Removal of iron and manganese using biological roughing up flow filtration technology.
Pacini, Virginia Alejandra; María Ingallinella, Ana; Sanguinetti, Graciela
2005-11-01
The removal of iron and manganese from groundwater using biological treatment methods is almost unknown in Latin America. Biological systems used in Europe are based on the process of double rapid biofiltration during which dissolved oxygen and pH need to be strictly controlled in order to limit abiotic iron oxidation. The performance of roughing filter technology in a biological treatment process for the removal of iron and manganese, without the use of chemical agents and under natural pH conditions was studied. Two pilot plants, using two different natural groundwaters, were operated with the following treatment line: aeration, up flow roughing filtration and final filtration (either slow or rapid). Iron and manganese removal efficiencies were found to be between 85% and 95%. The high solid retention capability of the roughing filter means that it is possible to remove iron and manganese simultaneously by biotic and abiotic mechanisms. This system combines simple, low-cost operation and maintenance with high iron and manganese removal efficiencies, thus constituting a technology which is particularly suited to small waterworks.
Silica incorporated membrane for wastewater based filtration
NASA Astrophysics Data System (ADS)
Fernandes, C. S.; Bilad, M. R.; Nordin, N. A. H. M.
2017-10-01
Membrane technology has long been applied for waste water treatment industries due to its numerous advantages compared to other conventional processes. However, the biggest challenge in pressure driven membrane process is membrane fouling. Fouling decreases the productivity and efficiency of the filtration, reduces the lifespan of the membrane and reduces the overall efficiency of water treatment processes. In this study, a novel membrane material is developed for water filtration. The developed membrane incorporates silica nanoparticles mainly to improve its structural properties. Membranes with different loadings of silica nanoparticles were applied in this study. The result shows an increase in clean water permeability and filterability of the membrane for treating activated sludge, microalgae solution, secondary effluent and raw sewage as feed. Adding silica into the membrane matrix does not significantly alter contact angle and membrane pore size. We believe that silica acts as an effective pore forming agent that increases the number of pores without significantly altering the pore sizes. A higher number of small pores on the surface of the membrane could reduce membrane fouling because of a low specific loading imposed to individual pores.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sawada, Y.; Fujii, R.; Igami, I.
The microporous polyethylene hollow-fiber membrane has a unique microfibrile structure throughout its depth and has been found to possess the functions of filtration and adsorption of endotoxin in water. The membrane has a maximum pore diameter of approximately 0.04 micron, a diameter which is within the range of microfiltration. Approximately 10 and 20% of the endotoxin in tap water and subterranean water, respectively, was smaller than 0.025 micron. Endotoxin in these water sources was efficiently removed by the microporous polyethylene hollow-fiber membrane. Escherichia coli O113 culture broth contained 26.4% of endotoxin smaller than 0.025 micron which was also removed. Endotoxinmore » was leaked into the filtrate only when endotoxin samples were successively passed through the membrane. These results indicate that endotoxin smaller than the pore size of the membrane was adsorbed and then leaked into the filtrate because of a reduction in binding sites. Dissociation of /sup 3/H-labeled endotoxin from the membrane was performed, resulting in the removal of endotoxin associated with the membrane by alcoholic alkali at 78% efficiency.« less
Hilton, Joan F.; Wright, Catherine C.; Arnold, Benjamin F.; Saha, Sona; Wade, Timothy J.; Scott, James; Eisenberg, Joseph N.S.
2009-01-01
Objectives. We estimated the relative rate of highly credible gastrointestinal illness (HCGI) per year associated with active versus sham household water filtration devices among older adults in a community receiving tap water meeting current US standards. Methods. We conducted a randomized, triple-blinded, crossover trial in 714 households (988 individuals), which used active and sham water filtration devices for 6 months each. We estimated the annual incidence rate ratio of HCGI episodes and the longitudinal prevalence ratio of HCGI days at population and individual levels with a generalized estimating equation (GEE) and generalized linear mixed models (GLMMs), respectively, adjusted for covariates associated with outcome. Results. The incidence rate ratios (active versus sham) were 0.88 (95% confidence interval [CI] = 0.77, 1.00) and 0.85 (95% CI = 0.76, 0.94) HCGI episodes per year estimated by GEE and GLMM models, respectively. The corresponding longitudinal prevalence ratios were 0.88 (95% CI = 0.74, 1.05) and 0.84 (95% CI = 0.78, 0.90) HCGI days per person per year. Conclusions. We observed reductions in population- and individual-level measures of HCGI associated with use of the active filtration device. These findings suggest the need for further research on the impact of drinking water on the health of sensitive subpopulations. PMID:19762663
Air filtration media from electrospun waste high-impact polystyrene fiber membrane
NASA Astrophysics Data System (ADS)
Zulfi, Akmal; Miftahul Munir, Muhammad; Hapidin, Dian Ahmad; Rajak, Abdul; Edikresnha, Dhewa; Iskandar, Ferry; Khairurrijal, Khairurrijal
2018-03-01
Nanofiber membranes were synthesized from waste high-impact polystyrene (HIPS) using electrospinning method and then applied as air filtration media. The waste HIPS precursor solution with the concentration of 20 wt.% was prepared by dissolving waste HIPS into the mixture of d-limonene and DMF solvents. Beaded or fine nanofibers could be achieved by adjusting the ratio of solvents mixture (d-limonene and DMF). Using the ratios of solvents (d-limonene: DMF) of 3:1, 1:1, and 1:3, it was obtained beaded HIPS nanofibers with the average diameter of 272 nm, beaded HIPS nanofibers with the average diameter of 937, and fine HIPS nanofibers with the average diameter of 621 nm, respectively. From the FTIR spectral analysis, it was found that the FTIR peaks of the HIPS nanofiber membranes are the same as those of the cleaned waste HIPS and there are no FTIR peaks of DMF and d-limonene solvents. These findings implied that the electrospinning process allows the recycling of waste HIPS into HIPS nanofibers without any trapped solvent phases or apparent degradation of the original material. From the contact angle measurement, it was confirmed that the HIPS nanofiber membranes are hydrophobic and the presence of the beads in the HIPS nanofiber membranes varies their contact angles. From the air-filtration test, it was shown that the fiber morphology (beaded or fine nanofibers) considerably affects the filtration performance of the membranes. The presence of beads increased the distance between the fibers so that the pressure drop decreased. Moreover, the basis weight of the membrane greatly affected the filtration efficiency. The HIPS nanofiber membrane with the basis weight of 12.22 g m‑2 had the efficiency greater than 99.999%, which was equivalent to that of the HEPA filter.
Assessment of Pollutant Removal Efficiency and Drainage Capacity in Stormwater Biofilters
NASA Astrophysics Data System (ADS)
Carroll, S. J.; Mills, H.; Reagan, A.; Triassi, M.; Bauer, S.; Matiasek, S. J.; Libby, R.; Meddings, C.
2016-12-01
Urban stormwater runoff contributes to flooding and impacts water quality with increased sediment and pollutant loads. Biofilters are vegetated filtration systems designed to mitigate stormwater by enhancing infiltration, sedimentation, contaminant sorption and uptake. Despite the rapid implementation of biofilters as stormwater management solutions, their performance is mainly evaluated in terms of flood reduction while their pollutant removal efficiency is rarely assessed. We investigated the effect of biofilter composition on drainage capacity and individual pollutant removal in test columns. Triplicate columns consisted of layers of pebbles, fine sand, filtration mix (test variable), mulch, lava rock and Santa Barbara sedges. The filtration mix was one of five combinations of coarse sand and local loam soil ranging from 100% sand to 100% soil. Consistent with differences in pore size distribution, hydraulic conductivity values were lowest in 100% soil biofilters (3.0 ± 0.6 mm/h) and highest in the 100% sand biofilters (22.7 ± 4.2 mm/h). A synthetic mixture of nutrients, metals, and salts in proportions representative of stormwater composition was applied to the test columns. Biofilters removed over 98% of dissolved copper, nickel, and zinc, and at least 67% of dissolved lead, even when applying synthetic runoff with metal concentrations three orders of magnitude larger than in actual stormwater. In addition, biofilters oxygenated, neutralized, and decreased the turbidity of stormwater. Ammonium was quantitatively removed from synthetic runoff (97-100%), while nitrate and phosphate were poorly retained (48-64%) or even leached from sand biofilters. This study demonstrated that, while decreasing drainage capacity, adding even a small proportion of native soil to the filtration media significantly increases pollutant removal of biofilters. With proper consideration of the filtration mixture, biofiltration systems can effectively remediate urban stormwater.
The use of an air filtration system in podiatry clinics.
McLarnon, Nichola; Burrow, Gordon; Maclaren, William; Aidoo, Kofi; Hepher, Mike
2003-06-01
A small-scale study was conducted to ascertain the efficiency and effectiveness of an air filtration system for use in podiatry/chiropody clinics (Electromedia Model 35F (A), Clean Air Ltd, Scotland, UK). Three clinics were identified, enabling comparison of data between podiatry clinics in the West of Scotland. The sampling was conducted using a portable Surface Air Sampler (Cherwell Laboratories, Bicester, UK). Samples were taken on two days at three different times before and after installation of the filtration units. The global results of the study indicate the filter has a statistically significant effect on microbial counts, with an average percentage decrease of 65%. This study is the first time, to the authors' knowledge, such a system has been tested within podiatric practice.
Tang, Tao; Zhang, Jun; Cao, Dongxiao; Shuai, Shijin; Zhao, Yanguang
2014-12-01
This study investigated the filtration and continuous regeneration of a particulate filter system on an engine test bench, consisting of a diesel oxidation catalyst (DOC) and a catalyzed diesel particulate filter (CDPF). Both the DOC and the CDPF led to a high conversion of NO to NO2 for continuous regeneration. The filtration efficiency on solid particle number (SPN) was close to 100%. The post-CDPF particles were mainly in accumulation mode. The downstream SPN was sensitively influenced by the variation of the soot loading. This phenomenon provides a method for determining the balance point temperature by measuring the trend of SPN concentration. Copyright © 2014. Published by Elsevier B.V.
Virus fate and transport during artificial recharge with recycled water
Anders, Robert; Chrysikopoulos, C.V.
2005-01-01
A field‐scale experiment was conducted at a research site using bacterial viruses (bacteriophage) MS2 and PRD1 as surrogates for human viruses, bromide as a conservative tracer, and tertiary‐treated municipal wastewater (recycled water) to investigate the fate and transport of viruses during artificial recharge. Observed virus concentrations were fitted using a mathematical model that simulates virus transport in one‐dimensional, homogeneous, water‐saturated porous media accounting for virus sorption (or filtration), virus inactivation, and time‐dependent source concentration. The fitted time‐dependent clogging rate constants were used to estimate the collision efficiencies for bacteriophage MS2 and PRD1 during vertical fully saturated flow. Furthermore, the corresponding time‐dependent collision efficiencies for both bacteriophage asymptotically reached similar values at the various sampling locations. These results can be used to develop an optimal management scenario to maximize the amount of recycled water that can be applied to the spreading grounds while still maintaining favorable attachment conditions for virus removal.
Comparison of MERV 16 and HEPA filters for cab filtration of underground mining equipment.
Cecala, A B; Organiscak, J A; Noll, J D; Zimmer, J A
2016-08-01
Significant strides have been made in optimizing the design of filtration and pressurization systems used on the enclosed cabs of mobile mining equipment to reduce respirable dust and provide the best air quality to the equipment operators. Considering all of the advances made in this area, one aspect that still needed to be evaluated was a comparison of the efficiencies of the different filters used in these systems. As high-efficiency particulate arrestance (HEPA) filters provide the highest filtering efficiency, the general assumption would be that they would also provide the greatest level of protection to workers. Researchers for the U.S. National Institute for Occupational Safety and Health (NIOSH) speculated, based upon a previous laboratory study, that filters with minimum efficiency reporting value, or MERV rating, of 16 may be a more appropriate choice than HEPA filters in most cases for the mining industry. A study was therefore performed comparing HEPA and MERV 16 filters on two kinds of underground limestone mining equipment, a roof bolter and a face drill, to evaluate this theory. Testing showed that, at the 95-percent confidence level, there was no statistical difference between the efficiencies of the two types of filters on the two kinds of mining equipment. As the MERV 16 filters were less restrictive, provided greater airflow and cab pressurization, cost less and required less-frequent replacement than the HEPA filters, the MERV 16 filters were concluded to be the optimal choice for both the roof bolter and the face drill in this comparative-analysis case study. Another key finding of this study is the substantial improvement in the effectiveness of filtration and pressurization systems when using a final filter design.
Comparison of MERV 16 and HEPA filters for cab filtration of underground mining equipment
Cecala, A.B.; Organiscak, J.A.; Noll, J.D.; Zimmer, J.A.
2016-01-01
Significant strides have been made in optimizing the design of filtration and pressurization systems used on the enclosed cabs of mobile mining equipment to reduce respirable dust and provide the best air quality to the equipment operators. Considering all of the advances made in this area, one aspect that still needed to be evaluated was a comparison of the efficiencies of the different filters used in these systems. As high-efficiency particulate arrestance (HEPA) filters provide the highest filtering efficiency, the general assumption would be that they would also provide the greatest level of protection to workers. Researchers for the U.S. National Institute for Occupational Safety and Health (NIOSH) speculated, based upon a previous laboratory study, that filters with minimum efficiency reporting value, or MERV rating, of 16 may be a more appropriate choice than HEPA filters in most cases for the mining industry. A study was therefore performed comparing HEPA and MERV 16 filters on two kinds of underground limestone mining equipment, a roof bolter and a face drill, to evaluate this theory. Testing showed that, at the 95-percent confidence level, there was no statistical difference between the efficiencies of the two types of filters on the two kinds of mining equipment. As the MERV 16 filters were less restrictive, provided greater airflow and cab pressurization, cost less and required less-frequent replacement than the HEPA filters, the MERV 16 filters were concluded to be the optimal choice for both the roof bolter and the face drill in this comparative-analysis case study. Another key finding of this study is the substantial improvement in the effectiveness of filtration and pressurization systems when using a final filter design. PMID:27524838
Value-added products from chicken feather fiber and protein
NASA Astrophysics Data System (ADS)
Fan, Xiuling
Worldwide poultry consumption has generated a huge amount of feather "waste" annually. Currently, the feather has a low value-being used for animal feed in the world. The quality of fibrous air filters depend on their main component, fibers. The main physical structure of chicken feathers is barbs which can be used directly as fibers. They have small diameter, which makes them a good choice for air filtration. The main chemical structure of chicken feathers is structural fibrous protein, keratin. Therefore, chicken feathers could potentially be used for protein fiber production. To obtain chicken feather fibers, barbs were stripped from the quills by a stripping device and separated with a blender. Some feather fibers were entangled with polyester staple fibers, and needlepunched to form a nonwoven fabric. Some feather fibers were blended with CelBond(TM) bi-component polyester as binder fibers, and pressed between two hot plates to produce thermobonded nonwovens. Whole chicken feathers were ground into powder and their keratin was reduced in water. The reduced keratin was salt precipitated, dried and dissolved in ionic liquid with/without bleach cotton. The reduced chicken feather keratin ionic liquid solutions were spun into regenerated fibers through dry-jet wet spinning. The needlepunched and thermobonded nonwovens were tested for filtration and other properties. With an increase of areal density and feather fiber composition, the air permeability of the needlepunched nonwovens decreased, and their filtration efficiency and pressure drop both increased. The case can be made that feather fibers gave fabrics better filtration at the same fabric weight, but at the expense of air permeability and pressure drop. The scrim and needlepunching process improved the filtration efficiency. Their strength depended on scrim. The hot-press process was very simple. The thermobonded nonwovens had very high air permeability. In them, there was also an inverse relation between air permeability and either pressure drop or filtration efficiency. From these kinds of nonwovens, it is realized that feather fibers' fineness and the tree/fan-like structure of the feather does not offer a high level of performance advantages over conventional fibers. The use of feather fiber in air filtration applications must rely primarily on a favorable cost and weight differential in favor of the feather fiber. Only after chicken feather keratin was reduced, could it dissolve well in ionic liquid. 100% chicken feather keratin did not produce high tenacity fibers. Reduced chicken feather keratin and cellulose produced blend fibers with mechanical properties close to silk, cotton, and polyester fibers. Chemically reforming crosslinks might improve mechanical properties and the stability of the fibers to water and make them suitable for most fibrous applications. From this, it can be proposed that using chicken feathers for fiber production may be a good way to add value to chicken feather "waste".
Choi, Jeongan; Yang, Byeong Joon; Bae, Gwi-Nam; Jung, Jae Hee
2015-11-18
Recently, with the increased attention to indoor air quality, antimicrobial air filtration techniques have been studied widely to inactivate hazardous airborne microorganisms effectively. In this study, we demonstrate herbal extract incorporated (HEI) nanofibers synthesized by an electrospinning technique and their application to antimicrobial air filtration. As an antimicrobial herbal material, an ethanolic extract of Sophora flavescens, which exhibits great antibacterial activity against pathogens, was mixed with the polymer solution for the electrospinning process. We measured various characteristics of the synthesized HEI nanofibers, such as fiber morphology, fiber size distribution, and thermal stability. For application of the electrospun HEI nanofibers, we made highly effective air filters with 99.99% filtration efficiency and 99.98% antimicrobial activity against Staphylococcus epidermidis. The pressure drop across the HEI nanofiber air filter was 4.75 mmH2O at a face air velocity of 1.79 cm/s. These results will facilitate the implementation of electrospun HEI nanofiber techniques to control air quality and protect against hazardous airborne microorganisms.
Antibacterial performance of nano polypropylene filter media containing nano-TiO2 and clay particles
NASA Astrophysics Data System (ADS)
Shafiee, Sara; Zarrebini, Mohammad; Naghashzargar, Elham; Semnani, Dariush
2015-10-01
Disinfection and elimination of pathogenic microorganisms from liquid can be achieved by filtration process using antibacterial filter media. The advent of nanotechnology has facilitated the introduction of membranes consisting of nano-fiber in filtration operations. The melt electro-spun fibers due to their extremely small diameters are used in the production of this particular filtration medium. In this work, antibacterial polypropylene filter medium containing clay particles and nano-TiO2 were made using melt electro-spun technology. Antibacterial performance of polypropylene nano-filters was evaluated using E. coli bacteria. Additionally, filtration efficiency of the samples in terms fiber diameter, filter porosity, and fiber distribution using image processing technique was determined. Air permeability and dust aerosol tests were conducted to establish the suitability of the samples as a filter medium. It was concluded that as far as antibacterial property is concerned, nano-fibers filter media containing clay particles are preferential to similar media containing TiO2 nanoparticles.
Chang, Shu-Hsuan; Tsai, Chia-Ti; Yen, Amy Ming-Fang; Lei, Meng-Huan; Chen, Hsiu-Hsi; Tseng, Chuen-Den
2015-03-01
The aim of this study was to evaluate the independent roles of proteinuria and reduced estimated glomerular filtration rate (GFR) in the development of acute myocardial infarction in a northern Taiwanese population. We conducted a community-based prospective cohort study in Keelung, the northernmost county of Taiwan. A total of 63,129 subjects (63% women) ≥ 20 years of age who had no history of coronary heart disease were recruited and followed-up. Univariate and multivariate proportional hazards regression analysis was performed to assess the association between proteinuria and estimated GFR and the risk of acute myocardial infarction. There were 305 new cases of acute myocardial infarction (114 women and 191 men) documented during a four-year follow-up period. After adjustment of potential confounding covariates, heavier proteinuria (dipstick urinalysis reading 3+) and estimated GFR of less than 60 ml/min/1.73 m(2) independently predicted increased risk of developing acute myocardial infarction. The adjusted hazard ratio (aHR) of heavier proteinuria for occurrence of acute myocardial infarction was 1.85 [95% confidence intervals (CI), 1.17-2.91, p < 0.01] (vs. the reference group: negative dipstick proteinuria). The aHR of estimated GFR of 30-59 ml/min/1.73 m(2) for occurrence of acute myocardial infarction was 2.4 (95% CI, 1.31-4.38, p < 0.01) (vs. the reference group: estimated GFR ≥ 90 ml/ min/1.73 m(2)), and that of estimated GFR of 15-29 ml/min/1.73 m(2) was 5.26 (95% CI, 2.26-12.26, p < 0.01). We demonstrated that both heavier proteinuria and lower estimated GFR are significant independent predictors of developing future acute myocardial infarction in a northern Taiwanese population. Acute myocardial infarction; Estimated glomerular filtration rate; Proteinuria.
Zeiler, T; Kretschmer, V
1997-01-01
This study reports on in-line filtration of 72 platelet concentrates (PC) collected by the Fresenius AS 104 cell separator, using the new C4F sets with integrated leukocyte filters (Biofil P plus). 72 volunteer donors, automatic counts of platelets, microscopical counting of residual leukocytes with the Nageotte chamber, GMP-140 by flow cytometrie, beta-thromboglobulin release, platelet aggregation (ADP, collagen). Filtration reduced leukocytes by 98.5%. Residual leukocyte contamination remained clearly below 5 x 10(6) (mean 0.5 +/- 0.6 x 10(6), maximum 2.8 x 10(6). Platelet loss by filtration was found to be between 27.4 and 0.7% (median 8.5%). Filtration caused a significant decrease of platelet aggregability (p < 0.005), but no significant increase of beta-thromboglobulin release and only a slight decrease of GMP-140 expression. From these data can be concluded that in-line filtration was highly efficient with acceptable platelet retention. No significant platelet activation could be observed in the PC. The decrease of platelet aggregability have been due to the reduction of activated platelets which are believed to show reduced in vivo survival.
Retinopathy and chronic kidney disease in the Chronic Renal Insufficiency Cohort (CRIC) study.
Grunwald, Juan E; Alexander, Judith; Ying, Gui-Shuang; Maguire, Maureen; Daniel, Ebenezer; Whittock-Martin, Revell; Parker, Candace; McWilliams, Kathleen; Lo, Joan C; Go, Alan; Townsend, Raymond; Gadegbeku, Crystal A; Lash, James P; Fink, Jeffrey C; Rahman, Mahboob; Feldman, Harold; Kusek, John W; Xie, Dawei; Jaar, Bernard G
2012-09-01
To investigate the association between retinopathy and chronic kidney disease. In this observational, cross-sectional study, 2605 patients of the Chronic Renal Insufficiency Cohort (CRIC) study, a multicenter study of chronic kidney disease, were offered participation. Nonmydriatic fundus photographs of the disc and macula in both eyes were obtained in 1936 of these subjects. The photographs were reviewed in a masked fashion at a central photograph reading center using standard protocols. Presence and severity of retinopathy (diabetic, hypertensive, or other) and vessel diameter caliber were assessed by trained graders and a retinal specialist using protocols developed for large epidemiologic studies. Kidney function measurements and information on traditional and nontraditional risk factors for decreased kidney function were obtained from the CRIC study. Greater severity of retinopathy was associated with lower estimated glomerular filtration rate after adjustment for traditional and nontraditional risk factors. The presence of vascular abnormalities usually associated with hypertension was also associated with lower estimated glomerular filtration rate. We found no strong direct relationship between estimated glomerular filtration rate and average arteriolar or venular calibers. Our findings show a strong association between severity of retinopathy and its features and level of kidney function after adjustment for traditional and nontraditional risk factors for chronic kidney disease, suggesting that retinovascular pathology reflects renal disease.
Viazzi, Francesca; Piscitelli, Pamela; Ceriello, Antonio; Fioretto, Paola; Giorda, Carlo; Guida, Pietro; Russo, Giuseppina; De Cosmo, Salvatore; Pontremoli, Roberto
2017-09-22
Apparent treatment resistant hypertension (aTRH) is highly prevalent in patients with type 2 diabetes mellitus (T2D) and entails worse cardiovascular prognosis. The impact of aTRH and long-term achievement of recommended blood pressure (BP) values on renal outcome remains largely unknown. We assessed the role of aTRH and BP on the development of chronic kidney disease in patients with T2D and hypertension in real-life clinical practice. Clinical records from a total of 29 923 patients with T2D and hypertension, with normal baseline estimated glomerular filtration rate and regular visits during a 4-year follow-up, were retrieved and analyzed. The association between time-updated BP control (ie, 75% of visits with BP <140/90 mm Hg) and the occurrence of estimated glomerular filtration rate <60 and/or a reduction ≥30% from baseline was assessed. At baseline, 17% of patients had aTRH. Over the 4-year follow-up, 19% developed low estimated glomerular filtration rate and 12% an estimated glomerular filtration rate reduction ≥30% from baseline. Patients with aTRH showed an increased risk of developing both renal outcomes (adjusted odds ratio, 1.31 and 1.43; P <0.001 respectively), as compared with those with non-aTRH. No association was found between BP control and renal outcomes in non-aTRH, whereas in aTRH, BP control was associated with a 30% ( P =0.036) greater risk of developing the renal end points. ATRH entails a worse renal prognosis in T2D with hypertension. BP control is not associated with a more-favorable renal outcome in aTRH. The relationship between time-updated BP and renal function seems to be J-shaped, with optimal systolic BP values between 120 and 140 mm Hg. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Candela-Toha, Ángel; Pardo, María Carmen; Pérez, Teresa; Muriel, Alfonso; Zamora, Javier
2018-04-20
and objective Acute kidney injury (AKI) diagnosis is still based on serum creatinine and diuresis. However, increases in creatinine are typically delayed 48h or longer after injury. Our aim was to determine the utility of routine postoperative renal function blood tests, to predict AKI one or 2days in advance in a cohort of cardiac surgery patients. Using a prospective database, we selected a sample of patients who had undergone major cardiac surgery between January 2002 and December 2013. The ability of the parameters to predict AKI was based on Acute Kidney Injury Network serum creatinine criteria. A cohort of 3,962 cases was divided into 2groups of similar size, one being exploratory and the other a validation sample. The exploratory group was used to show primary objectives and the validation group to confirm results. The ability to predict AKI of several kidney function parameters measured in routine postoperative blood tests, was measured with time-dependent ROC curves. The primary endpoint was time from measurement to AKI diagnosis. AKI developed in 610 (30.8%) and 623 (31.4%) patients in the exploratory and validation samples, respectively. Estimated glomerular filtration rate using the MDRD-4 equation showed the best AKI prediction capacity, with values for the AUC ROC curves between 0.700 and 0.946. We obtained different cut-off values for estimated glomerular filtration rate depending on the degree of AKI severity and on the time elapsed between surgery and parameter measurement. Results were confirmed in the validation sample. Postoperative estimated glomerular filtration rate using the MDRD-4 equation showed good ability to predict AKI following cardiac surgery one or 2days in advance. Copyright © 2018 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.
Oliveras, Anna; Armario, Pedro; Martell-Clarós, Nieves; Ruilope, Luis M; de la Sierra, Alejandro
2011-03-01
Microalbuminuria is a known marker of subclinical organ damage. Its prevalence is higher in patients with resistant hypertension than in subjects with blood pressure at goal. On the other hand, some patients with apparently well-controlled hypertension still have microalbuminuria. The current study aimed to determine the relationship between microalbuminuria and both office and 24-hour ambulatory blood pressure. A cohort of 356 patients (mean age 64 ± 11 years; 40.2% females) with resistant hypertension (blood pressure ≥ 140 and/or 90 mm Hg despite treatment with ≥ 3 drugs, diuretic included) were selected from Spanish hypertension units. Patients with estimated glomerular filtration rate <30 mL/min/1.73 m(2) were excluded. All patients underwent clinical and demographic evaluation, complete laboratory analyses, and good technical-quality 24-hour ambulatory blood pressure monitoring. Urinary albumin/creatinine ratio was averaged from 3 first-morning void urine samples. Microalbuminuria (urinary albumin/creatinine ratio ≥ 2.5 mg/mmol in males or ≥ 3.5 mg/mmol in females) was detected in 46.6%, and impaired renal function (estimated glomerular filtration rate <60 mL/min/1.73 m(2)) was detected in 26.8%. Bivariate analyses showed significant associations of microalbuminuria with older age, reduced estimated glomerular filtration rate, increased nighttime systolic blood pressure, and elevated daytime, nighttime, and 24-hour diastolic blood pressure. In a logistic regression analysis, after age and sex adjustment, elevated nighttime systolic blood pressure (multivariate odds ratio, 1.014 [95% CI, 1.001 to 1.026]; P=0.029) and reduced estimated glomerular filtration rate (multivariate odds ratio, 2.79 [95% CI, 1.57 to 4.96]; P=0.0005) were independently associated with the presence of microalbuminuria. We conclude that microalbuminuria is better associated with increased nighttime systolic blood pressure than with any other office and 24-hour ambulatory blood pressure monitoring parameters.
Effects of UVB radiation on grazing of two cladocerans from high-altitude Andean lakes
Rejas, Danny
2017-01-01
Climate change and water extraction may result in increased exposition of the biota to ultraviolet-B radiation (UVB) in high-altitude Andean lakes. Although exposition to lethal doses in these lakes is unlikely, sub-lethal UVB doses may have strong impacts in key compartments such as zooplankton. Here, we aimed at determining the effect of sub-lethal UVB doses on filtration rates of two cladoceran species (Daphnia pulicaria and Ceriodaphnia dubia). We firstly estimated the Incipient Limiting Concentration (ILC) and the Gut Passage Time (GPT) for both species. Thereafter we exposed clones of each species to four increasing UVB doses (treatments): i) DUV-0 (Control), ii) DUV-1 (0.02 MJ m2), iii) DUV-2 (0.03 MJ m2) and iv) DUV-3 (0.15 MJ m2); and estimated their filtration rates using fluorescent micro-spheres. Our results suggest that increasing sub-lethal doses of UVB radiation may strongly disturb the structure and functioning of high-altitude Andean lakes. Filtration rates of D. pulicaria were not affected by the lowest dose applied (DUV-1), but decreased by 50% in treatments DUV-2 and DUV-3. Filtration rates for C. dubia were reduced by more than 80% in treatments DUV-1 and DUV-2 and 100% of mortality occurred at the highest UVB dose applied (DUV-3). PMID:28379975
Development of a filter to prevent infections with spore-forming bacteria in injecting drug users.
Alhusein, Nour; Scott, Jenny; Kasprzyk-Hordern, Barbara; Bolhuis, Albert
2016-12-01
In heroin injectors, there have been a number of outbreaks caused by spore-forming bacteria, causing serious infections such as anthrax or botulism. These are, most likely, caused by injecting contaminated heroin, and our aim was to develop a filter that efficiently removes these bacteria and is also likely to be acceptable for use by people who inject drugs (i.e. quick, simple and not spoil the hit). A prototype filter was designed and different filter membranes were tested to assess the volume of liquid retained, filtration time and efficiency of the filter at removing bacterial spores. Binding of active ingredients of heroin to different types of membrane filters was determined using a highly sensitive analytical chemistry technique. Heroin samples that were tested contained up to 580 bacteria per gramme, with the majority being Bacillus spp., which are spore-forming soil bacteria. To remove these bacteria, a prototype filter was designed to fit insulin-type syringes, which are commonly used by people who inject drugs (PWIDs). Efficient filtration of heroin samples was achieved by combining a prefilter to remove particles and a 0.22 μm filter to remove bacterial spores. The most suitable membrane was polyethersulfone (PES). This membrane had the shortest filtration time while efficiently removing bacterial spores. No or negligible amounts of active ingredients in heroin were retained by the PES membrane. This study successfully produced a prototype filter designed to filter bacterial spores from heroin samples. Scaled up production could produce an effective harm reduction tool, especially during outbreaks such as occurred in Europe in 2009/10 and 2012.
Li, Jian; Kang, Ruimei; Tang, Xiaohua; She, Houde; Yang, Yaoxia; Zha, Fei
2016-04-14
Oil-polluted water has become a worldwide problem due to increasing industrial oily wastewater as well as frequent oil-spill pollution. Compared with underwater superoleophobic (water-removing) filtration membranes, superhydrophobic/superoleophilic (oil-removing) materials have advantages as they can be used for the filtration of heavy oil or the absorption of floating oil from water/oil mixtures. However, most of the superhydrophobic materials used for oil/water separation lose their superhydrophobicity when exposed to hot (e.g. >50 °C) water and strong corrosive liquids. Herein, we demonstrate superhydrophobic overlapped candle soot (CS) and silica coated meshes that can repel hot water (about 92 °C) and strong corrosive liquids, and were used for the gravity driven separation of oil-water mixtures in hot water and strong acidic, alkaline, and salty environments. To the best of our knowledge, we are unaware of any previously reported studies on the use of superhydrophobic materials for the separation of oil from hot water and corrosive aqueous media. In addition, the as-prepared robust superhydrophobic CS and silica coated meshes can separate a series of oils and organic solvents like kerosene, toluene, petroleum ether, heptane and chloroform from water with a separation efficiency larger than 99.0%. Moreover, the as-prepared coated mesh still maintained a separation efficiency above 98.5% and stable recyclability after 55 cycles of separation. The robust superhydrophobic meshes developed in this work can therefore be practically used as a highly efficient filtration membrane for the separation of oil from harsh water conditions, benefiting the environment and human health.
Park, Walter D; Larson, Timothy S; Griffin, Matthew D; Stegall, Mark D
2012-11-15
After the first year after kidney transplantation, 3% to 5% of grafts fail each year but detailed studies of how grafts progress to failure are lacking. This study aimed to analyze the functional stability of kidney transplants between 1 and 5 years after transplantation and to identify initially well-functioning grafts with progressive decline in allograft function. The study included 788 adult conventional kidney transplants performed at the Mayo Clinic Rochester between January 2000 and December 2005 with a minimum graft survival and follow-up of 2.6 years. The modification of diet in renal disease equation for estimating glomerular filtration rate (eGFR(MDRD)) was used to calculate the slope of renal function over time using all available serum creatinine values between 1 and 5 years after transplantation. Most transplants demonstrated good function (eGFR(MDRD) ≥40 mL/min) at 1 year with positive eGFR(MDRD) slope between 1 and 5 years after transplantation. However, a subset of grafts with 1-year eGFR(MDRD) ≥40 mL/min exhibited strongly negative eGFR(MDRD) slope between 1 and 5 years suggestive of progressive loss of graft function. Forty-one percent of this subset reached graft failure during follow-up, accounting for 69% of allograft failures occurring after 2.5 years after transplantation. This pattern of progressive decline in estimated glomerular filtration rate despite good early function was associated with but not fully attributable to factors suggestive of enhanced antidonor immunity. Longitudinal analysis of serial estimated glomerular filtration ratemeasurements identifies initially well-functioning kidney transplants at high risk for subsequent graft loss. For this subset, further studies are needed to identify modifiable causes of functional decline.
Li, Z; Wang, A; Cai, J; Gao, X; Zhou, Y; Luo, Y; Wu, S; Zhao, X
2015-02-01
Persons with chronic kidney disease, defined by a reduced estimated glomerular filtration rate and proteinuria, have an increased risk of cardiovascular disease including stroke. However, data from developing countries are limited. Our aim was to assess the relationship between chronic kidney disease and risk of stroke and its subtypes in a community-based population in China. The study was based on 92,013 participants (18-98 years old; 73,248 men and 18,765 women) of the Kailuan study who at baseline were free from stroke and myocardial infarction and had undergone tests for serum creatinine or proteinuria. Glomerular filtration rate was estimated using the Chronic Kidney Disease Epidemiology Collaboration formula and proteinuria by the urine dipstick result in laboratory databases. The primary outcome was the first occurrence of stroke. Data were analyzed using Cox proportional hazards models adjusted for relevant confounders and results are presented as hazard ratios (HRs) with 95% confidence intervals (CIs). During a follow-up of 4 years, 1575 stroke events (1128 ischaemic, 406 intracerebral hemorrhagic and 41 subarachnoid hemorrhagic strokes) occurred. After adjustment for variable confounders, patients with proteinuria were found to have increased HRs for the total and subtypes of stroke events (HR 1.61; 95% CI 1.35-1.92 for total stroke; HR 1.53; 95% CI 1.24-1.89 for ischaemic stroke; and HR 1.90; 95% CI 1.35-2.67 for hemorrhagic stroke). However, estimated glomerular filtration rate was not associated with incident stroke after adjustment for established cardiovascular risk factors. Proteinuria increased the risk of stroke in a general Chinese population. © 2014 EAN.
Tang, Xiaobin; Ding, An; Qu, Fangshu; Jia, Ruibao; Chang, Haiqing; Cheng, Xiaoxiang; Liu, Bin; Li, Guibai; Liang, Heng
2016-08-01
A pilot-scale gravity-driven membrane (GDM) filtration system under low gravitational pressure without any pre-treatment, backwash, flushing, or chemical cleaning was carried out to investigate the effect of operation parameters (including operation pressure, aeration mode, and intermittent filtration) on the effluent quality and permeability development. The results revealed that GDM system exhibited an efficient performance for the removal of suspended substances and organic compounds. The stabilization of flux occurred and the average values of stable flux were 6.6, 8.1, and 8.6 Lm(-2) h(-1) for pressures of 65, 120, and 200 mbar, respectively. In contrast, flux stabilization was not observed under continuous and intermittent aeration conditions. However, aeration (especially continuous aeration) was effective to improve flux and alleviate membrane fouling during 1-month operation. Moreover, intermittent filtration would influence the stabilization of permeate flux, resulting in a higher stable flux (ranging from 6 to 13 Lm(-2) h(-1)). The stable flux significantly improved with the increase of intermittent period. Additionally, GDM systems exhibited an efficient recovery of flux after simple physical cleaning and the analyses of resistance reversibility demonstrated that most of the total resistance was hydraulic reversible resistance (50-75 %). Therefore, it is expected that the results of this study can develop strategies to increase membrane permeability and reduce energy consumption in GDM systems for decentralized water supply.
Treatment of Wastewater From Car Washes Using Natural Coagulation and Filtration System
NASA Astrophysics Data System (ADS)
Al-Gheethi, A. A.; Mohamed, R. M. S. R.; Rahman, M. A. A.; Johari, M. R.; Kassim, A. H. M.
2016-07-01
Wastewater generated from carwash is one of the main wastewater resources, which contribute effectively in the increasing of environmental contamination due to the chemical characteristics of the car wastes. The present work aimed to develop an integrated treatment system for carwash wastewater based on coagulation and flocculation using Moringa oleifera and Ferrous Sulphate (FeSO4.7H2O) as well as natural filtration system. The carwash wastewater samples were collected from carwash station located at Parit Raja, Johor, Malaysia. The treatment system of car wash wastewater was designed in the lab scale in four stages included, aeration, coagulation and flocculation, sedimentation and filtration. The coagulation and flocculation unit was carried out using different dosage (35, 70, 105 and 140 mg L-1) of M. oleifera and FeSO4.7H2O, respectively. The efficiency of the integrated treatment system to treat carwash wastewater and to meet Environmental Quality Act (EQA 1974) was evaluated based on the analysis of pH, dissolved oxygen (DO), chemical oxygen demand (COD) and turbidity (NTU). The integrated treatment system was efficient for treatment of raw carwash wastewater. The treated carwash wastewaters meet EQA 1974 regulation 2009 (Standards A) in the term of pH and DO while, turbidity and COD reduced in the wastewater to meet Standards B. The integrated treatment system designed here with natural coagulant (M. oleifera) and filtration unit were effective for primary treatment of carwash wastewater before the final disposal or to be reused again for carwash process.
Development of a low-cost biogas filtration system to achieve higher-power efficient AC generator
NASA Astrophysics Data System (ADS)
Mojica, Edison E.; Ardaniel, Ar-Ar S.; Leguid, Jeanlou G.; Loyola, Andrea T.
2018-02-01
The paper focuses on the development of a low-cost biogas filtration system for alternating current generator to achieve higher efficiency in terms of power production. A raw biogas energy comprises of 57% combustible element and 43% non-combustible elements containing carbon dioxide (36%), water vapor (5%), hydrogen sulfide (0.5%), nitrogen (1%), oxygen (0 - 2%), and ammonia (0 - 1%). The filtration system composes of six stages: stage 1 is the water scrubber filter intended to remove the carbon dioxide and traces of hydrogen sulfide; stage 2 is the silica gel filter intended to reduce the water vapor; stage 3 is the iron sponge filter intended to remove the remaining hydrogen sulfide; stage 4 is the sodium hydroxide solution filter intended to remove the elemental sulfur formed during the interaction of the hydrogen sulfide and the iron sponge and for further removal of carbon dioxide; stage 5 is the silica gel filter intended to further eliminate the water vapor gained in stage 4; and, stage 6 is the activated carbon filter intended to remove the carbon dioxide. The filtration system was able to lower the non-combustible elements by 72% and thus, increasing the combustible element by 54.38%. The unfiltered biogas is capable of generating 16.3 kW while the filtered biogas is capable of generating 18.6 kW. The increased in methane concentration resulted to 14.11% increase in the power output. The outcome resulted to better engine performance in the generation of electricity.
Kim, Kyung-Jo; Jang, Am
2018-04-01
To enhance the removal of natural organic matter (NOM) in ceramic (Ce) membrane filtration, an iron-aluminum binary oxide (FAO) was applied to the ceramic membrane surface as the adsorbent cake layer, and it was compared with heated aluminum oxide (HAO) for the evaluation of the control of NOM. Both the HAO and FAO adsorbent cake layers efficiently removed the NOM regardless of NOM's hydrophobic/hydrophilic characteristics, and the dissolved organic carbon (DOC) removal in NOM for FAO was 1-1.12 times greater than that for HAO, which means FAO was more efficient in the removal of DOC in NOM. FAO (0.03 μm), which is smaller in size than HAO (0.4 μm), had greater flux reduction than HAO. The flux reduction increased as the filtration proceeded because most of the organic foulants (colloid/particles and soluble NOM) were captured by the adsorbent cake layer, which caused fouling between the membrane surface and the adsorbent cake layer. However, no chemically irreversible fouling was observed on the Ce membrane at the end of the FAO adsorbent cake layer filtration. This means that a stable adsorbent cake layer by FAO formed on the Ce membrane, and that the reduced pure water flux of the Ce membrane, resulting from the NOM fouling, can easily be recovered through physicochemical cleaning. Copyright © 2018 Elsevier Ltd. All rights reserved.
Structural ordering of casein micelles on silicon nitride micro-sieves during filtration.
Gebhardt, Ronald; Holzmüller, Wolfgang; Zhong, Qi; Müller-Buschbaum, Peter; Kulozik, Ulrich
2011-11-01
The paper reports on the structure and formation of casein micelle deposits on silicon nitride micro-sieves during the frontal filtration. The most frequent radius of the fractionated casein micelles we use is R=60 nm as detected by static light scattering (SLS) and atomic force microscopy (AFM). We estimate the size and size distribution of the casein micelles which pass through the micro-sieve during the filtration process. A sharpening of the size distribution at the beginning of the filtration process (t=40s) is followed by a broadening and a shift of the most frequent radii towards smaller sizes at later times (t=840 s). The size distribution of the micelles deposited on the micro-sieve during filtration is bimodal and consists of the largest and smallest micelles. At larger filtration times, we observe a shift of both deposited size classes towards smaller sizes. The atomic force micrographs of the reference sample reveal a tendency of the casein micelles to order in a hexagonal lattice when deposited on the micro-sieves by solution casting. The deposition of two size classes can be explained by a formation of a mixed hexagonal lattice with large micelles building up the basis lattice and smaller sizes filling octahedral and tetrahedral holes of the lattice. The accompanied compression with increasing thickness of the casein layer could result from preferential deposition of smaller sizes in the course of the filtration. Copyright © 2011 Elsevier B.V. All rights reserved.
Methodology for modeling the microbial contamination of air filters.
Joe, Yun Haeng; Yoon, Ki Young; Hwang, Jungho
2014-01-01
In this paper, we propose a theoretical model to simulate microbial growth on contaminated air filters and entrainment of bioaerosols from the filters to an indoor environment. Air filter filtration and antimicrobial efficiencies, and effects of dust particles on these efficiencies, were evaluated. The number of bioaerosols downstream of the filter could be characterized according to three phases: initial, transitional, and stationary. In the initial phase, the number was determined by filtration efficiency, the concentration of dust particles entering the filter, and the flow rate. During the transitional phase, the number of bioaerosols gradually increased up to the stationary phase, at which point no further increase was observed. The antimicrobial efficiency and flow rate were the dominant parameters affecting the number of bioaerosols downstream of the filter in the transitional and stationary phase, respectively. It was found that the nutrient fraction of dust particles entering the filter caused a significant change in the number of bioaerosols in both the transitional and stationary phases. The proposed model would be a solution for predicting the air filter life cycle in terms of microbiological activity by simulating the microbial contamination of the filter.
Particle Collection Efficiency of a Lens-Liquid Filtration System
NASA Astrophysics Data System (ADS)
Wong, Ross Y. M.; Ng, Moses L. F.; Chao, Christopher Y. H.; Li, Z. G.
2011-09-01
Clinical and epidemiological studies have shown that indoor air quality has substantial impact on the health of building occupants [1]. Possible sources of indoor air contamination include hazardous gases as well as particulate matters (PMs) [2]. Experimental studies show that the size distribution of PMs in indoor air ranges from tens of nanometers to a few hundreds of micrometers [3]. Vacuum cleaners can be used as a major tool to collect PMs from floor/carpets, which are the main sources of indoor PMs. However, the particle collection efficiency of typical cyclonic filters in the vacuums drops significantly for particles of diameter below 10 μm. In this work, we propose a lens-liquid filtration system (see Figure 1), where the flow channel is formed by a liquid free surface and a planar plate with fin/lens structures. Computational fluid dynamics simulations are performed by using FLUENT to optimize the structure of the proposed system toward high particle collection efficiency and satisfactory pressure drop. Numerical simulations show that the system can collect 250 nm diameter particles with collection efficiency of 50%.
Lu, Ping; Amburgey, James E; Hill, Vincent R; Murphy, Jennifer L; Schneeberger, Chandra L; Arrowood, Michael J; Yuan, Tao
2017-06-01
Removal of Cryptosporidium-sized microspheres and Cryptosporidium parvum oocysts from swimming pools was investigated using diatomaceous earth (DE) precoat filtration and perlite-sand filtration. In pilot-scale experiments, microsphere removals of up to 2 log were obtained with 0.7 kg·DE/m 2 at a filtration rate of 5 m/h. A slightly higher microsphere removal (2.3 log) was obtained for these DE-precoated filters when the filtration rate was 3.6 m/h. Additionally, pilot-scale perlite-sand filters achieved greater than 2 log removal when at least 0.37 kg/m 2 of perlite was used compared to 0.1-0.4 log removal without perlite both at a surface loading rate of 37 m/h. Full-scale testing achieved 2.7 log of microspheres and oocysts removal when 0.7 kg·DE/m 2 was used at 3.6 m/h. Removals were significantly decreased by a 15-minute interruption of the flow (without any mechanical agitation) to the DE filter in pilot-scale studies, which was not observed in full-scale filters. Microsphere removals were 2.7 log by perlite-sand filtration in a full-scale swimming pool filter operated at 34 m/h with 0.5 kg/m 2 of perlite. The results demonstrate that either a DE precoat filter or a perlite-sand filter can improve the efficiency of removal of microspheres and oocysts from swimming pools over a standard sand filter under the conditions studied.
NASA Astrophysics Data System (ADS)
Qarib, Hossein; Adeli, Hojjat
2015-12-01
In this paper authors introduce a new adaptive signal processing technique for feature extraction and parameter estimation in noisy exponentially damped signals. The iterative 3-stage method is based on the adroit integration of the strengths of parametric and nonparametric methods such as multiple signal categorization, matrix pencil, and empirical mode decomposition algorithms. The first stage is a new adaptive filtration or noise removal scheme. The second stage is a hybrid parametric-nonparametric signal parameter estimation technique based on an output-only system identification technique. The third stage is optimization of estimated parameters using a combination of the primal-dual path-following interior point algorithm and genetic algorithm. The methodology is evaluated using a synthetic signal and a signal obtained experimentally from transverse vibrations of a steel cantilever beam. The method is successful in estimating the frequencies accurately. Further, it estimates the damping exponents. The proposed adaptive filtration method does not include any frequency domain manipulation. Consequently, the time domain signal is not affected as a result of frequency domain and inverse transformations.
New approach to reducing water consumption in commercial kitchen hood
NASA Astrophysics Data System (ADS)
Asmuin, N.; Pairan, M. R.
2017-09-01
Water mist sprays are used in wide range of application. However it is depend to the spray characteristic to suit the particular application. The modern commercial kitchen hood ventilation system was adopted with the water mist nozzle technology as an additional tool to increase the filtration efficiency. However, low level of filtration effectiveness and high water consumption were the major problems among the Commercial Kitchen Ventilation expert. Therefore, this study aims to develop a new mist spray technology to replacing the conventional KSJB nozzle (KSJB is a nozzle’s name). At the same time, an appropriate recommended location to install the nozzle in kitchen hood system was suggested. An extensive simulation works were carried out to observe the spray characteristics, ANSYS (FLUENT) was used for simulation wise. In the case of nozzle studies, nozzles were tested at 1 bar pressure of water and air. In comparison with conventional nozzles configuration, this new approach suggested nozzle configuration was reduce up to 50% of water consumption, which by adopted 3 numbers of nozzles instead of 6 numbers of nozzles in the commercial kitchen hood system. Therefore, this nozzle will be used in industry for their benefits of water consumption, filtration efficiency and reduced the safety limitations.
Mermillod-Blondin, Florian; Simon, Laurent; Maazouzi, Chafik; Foulquier, Arnaud; Delolme, Cécile; Marmonier, Pierre
2015-09-15
Managed aquifer recharge (MAR) has been developed in many countries to limit the risk of urban flooding and compensate for reduced groundwater recharge in urban areas. The environmental performances of MAR systems like infiltration basins depend on the efficiency of soil and vadose zone to retain stormwater-derived contaminants. However, these performances need to be finely evaluated for stormwater-derived dissolved organic matter (DOM) that can affect groundwater quality. Therefore, this study examined the performance of MAR systems to process DOM during its transfer from infiltration basins to an urban aquifer. DOM characteristics (fluorescent spectroscopic properties, biodegradable and refractory fractions of dissolved organic carbon -DOC-, consumption by micro-organisms during incubation in slow filtration sediment columns) were measured in stormwater during its transfer through three infiltration basins during a stormwater event. DOC concentrations sharply decreased from surface to the aquifer for the three MAR sites. This pattern was largely due to the retention of biodegradable DOC which was more than 75% for the three MAR sites, whereas the retention of refractory DOC was more variable and globally less important (from 18% to 61% depending on MAR site). Slow filtration column experiments also showed that DOC retention during stormwater infiltration through soil and vadose zone was mainly due to aerobic microbial consumption of the biodegradable fraction of DOC. In parallel, measurements of DOM characteristics from groundwaters influenced or not by MAR demonstrated that stormwater infiltration increased DOC quantity without affecting its quality (% of biodegradable DOC and relative aromatic carbon content -estimated by SUVA254-). The present study demonstrated that processes occurring in soil and vadose zone of MAR sites were enough efficient to limit DOC fluxes to the aquifer. Nevertheless, the enrichments of DOC concentrations measured in groundwater below infiltration basins need to be considered in future studies to especially assess their impact on groundwater quality. Copyright © 2015 Elsevier Ltd. All rights reserved.
Filter-based control of particulate matter from a lean gasoline direct injection engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parks, II, James E; Lewis Sr, Samuel Arthur; DeBusk, Melanie Moses
New regulations requiring increases in vehicle fuel economy are challenging automotive manufacturers to identify fuel-efficient engines for future vehicles. Lean gasoline direct injection (GDI) engines offer significant increases in fuel efficiency over the more common stoichiometric GDI engines already in the marketplace. However, particulate matter (PM) emissions from lean GDI engines, particularly during stratified combustion modes, are problematic for lean GDI technology to meet U.S. Environmental Protection Agency Tier 3 and other future emission regulations. As such, the control of lean GDI PM with wall-flow filters, referred to as gasoline particulate filter (GPF) technology, is of interest. Since lean GDImore » PM chemistry and morphology differ from diesel PM (where more filtration experience exists), the functionality of GPFs needs to be studied to determine the operating conditions suitable for efficient PM removal. In addition, lean GDI engine exhaust temperatures are generally higher than diesel engines which results in more continuous regeneration of the GPF and less presence of the soot cake layer common to diesel particulate filters. Since the soot layer improves filtration efficiency, this distinction is important to consider. Research on the emission control of PM from a lean GDI engine with a GPF was conducted on an engine dynamometer. PM, after dilution, was characterized with membrane filters, organic vs. elemental carbon characterization, and size distribution techniques at various steady state engine speed and load points. The engine was operated in three primary combustion modes: stoichiometric, lean homogeneous, and lean stratified. In addition, rich combustion was utilized to simulate PM from engine operation during active regeneration of lean NOx control technologies. High (>95%) PM filtration efficiencies were observed over a wide range of conditions; however, some PM was observed to slip through the GPF at high speed and load conditions. The PM characterization at various engine speeds and loads will help enable optimized GPF design and control to achieve more fuel efficient lean GDI vehicles with low PM emissions.« less
Zipf, Mariah Siebert; Pinheiro, Ivone Gohr; Conegero, Mariana Garcia
2016-07-01
One of the main actions of sustainability that is applicable to residential, commercial, and public buildings is the rational use of water that contemplates the reuse of greywater as one of the main options for reducing the consumption of drinking water. Therefore, this research aimed to study the efficiencies of simplified treatments for greywater reuse using slow sand and slow slate waste filtration, both followed by granular activated carbon filters. The system monitoring was conducted over 28 weeks, using analyses of the following parameters: pH, turbidity, apparent color, biochemical oxygen demand (BOD), chemical oxygen demand (COD), surfactants, total coliforms, and thermotolerant coliforms. The system was run at two different filtration rates: 6 and 2 m(3)/m(2)/day. Statistical analyses showed no significant differences in the majority of the results when filtration rate changed from 6 to 2 m(3)/m(2)/day. The average removal efficiencies with regard to the turbidity, apparent color, COD and BOD were 61, 54, 56, and 56%, respectively, for the sand filter, and 66, 61, 60, and 51%, respectively, for the slate waste filter. Both systems showed good efficiencies in removing surfactants, around 70%, while the pH reached values of around 7.80. The average removal efficiencies of the total and thermotolerant coliforms were of 61 and 90%, respectively, for the sand filter, and 67 and 80%, respectively, for the slate waste filter. The statistical analysis found no significant differences between the responses of the two systems, which attest to the fact that the slate waste can be a substitute for sand. The maximum levels of efficiency were high, indicating the potential of the systems, and suggesting their optimization in order to achieve much higher average efficiencies. Copyright © 2016 Elsevier Ltd. All rights reserved.
... small-particle or high-efficiency particulate air (HEPA) filter. Shampoo the carpet frequently. Curtains and blinds. Use ... dander they shed. Air filtration. Choose an air filter that has a small-particle or HEPA filter. ...
Penetration of diesel exhaust particles through commercially available dust half masks.
Penconek, Agata; Drążyk, Paulina; Moskal, Arkadiusz
2013-04-01
Half masks are certified by the competent, national institutions--National Institute for Occupational Safety and Health (NIOSH) in the USA and the respective European national institutions applying common European regulations. However, certification testing is conducted with particles of NaCl, paraffin oil, or dioctyl phthalate (DOP) and at the constant flow rate, whereas particles commonly found in workplaces may differ in size, shape, and morphology from these particles. Therefore, the aim of this study was to investigate filtration efficiency of commercially available filtering facepiece half masks under the condition of exposure to diesel fumes. In this study, we focused on the particulate phase [diesel exhaust particles (DEP)] of three (petroleum diesel, ecodiesel, and biodiesel) diesel fuel combustion types. Two types of European standard-certified half masks, FFP2 and FFP - Filtering Facepiece, and three types of popular diesel fuels were tested. The study showed that the filtration efficiencies for each examined half mask and for each of diesel exhaust fumes were lower than the minimum filtration efficiency required for the standard test aerosols by the European standards. For FFP2 and FFP3 particulate half masks, standard minimum filtration efficiency is 94 and 99%, respectively, whereas 84-89% of mass of DEP from various fuels were filtered by the tested FFP2 and only 75-86% by the FFP3. The study indicated that DEP is more penetrating for these filters than the standard salt or paraffin oil test aerosols. The study also showed that the most penetrating DEP are probably in the 30- to 300-nm size range, regardless of the fuel type and the half-mask model. Finally, the pressure drops across both half masks during the 80-min tests remained below an acceptable maximum of breathing resistance-regardless of the fuel types. The respiratory system, during 40-min test exposures, may be exposed to 12-16mg of DEP if a FFP2 or FFP3 particulate half mask is used. To conclude, commercially available half masks may not ensure a sufficient level of protection of the respiratory tract against diesel exhaust fumes.
Visualization of flow during cleaning process on a liquid nanofibrous filter
NASA Astrophysics Data System (ADS)
Bílek, P.
2017-10-01
This paper deals with visualization of flow during cleaning process on a nanofibrous filter. Cleaning of a filter is very important part of the filtration process which extends lifetime of the filter and improve filtration properties. Cleaning is carried out on flat-sheet filters, where particles are deposited on the filter surface and form a filtration cake. The cleaning process dislodges the deposited filtration cake, which is loose from the membrane surface to the retentate flow. The blocked pores in the filter are opened again and hydrodynamic properties are restored. The presented optical method enables to see flow behaviour in a thin laser sheet on the inlet side of a tested filter during the cleaning process. The local concentration of solid particles is possible to estimate and achieve new information about the cleaning process. In the article is described the cleaning process on nanofibrous membranes for waste water treatment. The hydrodynamic data were compared to the images of the cleaning process.
Bilad, M R; Discart, V; Vandamme, D; Foubert, I; Muylaert, K; Vankelecom, Ivo F J
2013-06-01
This study was performed to investigate the effectiveness of submerged microfiltration to harvest both a marine diatom Phaeodactylum tricornutum and a Chlorella vulgaris in a recently developed magnetically induced membrane vibrating (MMV) system. We assess the filtration performance by conducting the improved flux step method (IFM), fed-batch concentration filtrations and membrane fouling autopsy using two lab-made membranes with different porosity. The full-scale energy consumption was also estimated. Overall results suggest that the MMV offers a good fouling control and the process was proven to be economically attractive. By combining the membrane filtration (15× concentration) with centrifugation to reach a final concentration of 25% w/v, the energy consumption to harvest P. tricornutum and C. vulgaris was, respectively, as low as 0.84 and 0.77kWh/m(3), corresponding to 1.46 and 1.39 kWh/kg of the harvested biomass. Copyright © 2013 Elsevier Ltd. All rights reserved.
Fleischman, Rafael; Amiel, Ran; Czerwinski, Jan; Mayer, Andreas; Tartakovsky, Leonid
2018-05-01
Retrofitting older vehicles with diesel particulate filter (DPF) is a cost-effective measure to quickly and efficiently reduce particulate matter emissions. This study experimentally analyzes real-world performance of buses retrofitted with CRT DPFs. 18 in-use Euro III technology urban and intercity buses were investigated for a period of 12months. The influence of the DPF and of the vehicle natural aging on buses fuel economy are analyzed and discussed. While the effect of natural deterioration is about 1.2%-1.3%, DPF contribution to fuel economy penalty is found to be 0.6% to 1.8%, depending on the bus type. DPF filtration efficiency is analyzed throughout the study and found to be in average 96% in the size range of 23-560nm. Four different load and non-load engine operating modes are investigated on their appropriateness for roadworthiness tests. High idle is found to be the most suitable regime for PN diagnostics considering particle number filtration efficiency. Copyright © 2017. Published by Elsevier B.V.
Storck, Florian R; Schmidt, Carsten K; Wülser, Richard; Brauch, Heinz-Jürgen
2012-01-01
Drinking water is often produced from surface water by riverbank filtration (RBF) or artificial groundwater recharge (AGR). In this study, an AGR system was exemplarily investigated and results were compared with those of RBF systems, in which the effects of redox milieu, temperature and surface water discharge on the cleaning efficiency were evaluated. Besides bulk parameters such as DOC (dissolved organic carbon), organic trace pollutants including iodinated X-ray contrast media, personal care products, complexing agents, and pharmaceuticals were investigated. At all studied sites, levels of TOC (total organic carbon), DOC, AOX (adsorbable organic halides), SAC (spectral absorption coefficient at 254 nm), and turbidity were reduced significantly. DOC removal was stimulated at higher groundwater temperatures during AGR. Several substances were generally easily removable during both AGR and RBF, regardless of the site, season, discharge or redox regime. For some more refractory substances, however, removal efficiency turned out to be significantly influenced by redox conditions.
NASA Astrophysics Data System (ADS)
Grubov, V. V.; Runnova, A. E.; Hramov, A. E.
2018-05-01
A new method for adaptive filtration of experimental EEG signals in humans and for removal of different physiological artifacts has been proposed. The algorithm of the method includes empirical mode decomposition of EEG, determination of the number of empirical modes that are considered, analysis of the empirical modes and search for modes that contains artifacts, removal of these modes, and reconstruction of the EEG signal. The method was tested on experimental human EEG signals and demonstrated high efficiency in the removal of different types of physiological EEG artifacts.
Huang, Gui-Wen; Xiao, Hong-Mei; Fu, Shao-Yun
2014-08-07
Here a facile, green and efficient printing-filtration-press (PFP) technique is reported for room-temperature (RT) mass-production of low-cost, environmentally friendly, high performance paper-based electronic circuits. The as-prepared silver nanowires (Ag-NWs) are uniformly deposited at RT on a pre-printed paper substrate to form high quality circuits via vacuum filtration and pressing. The PFP circuit exhibits more excellent electrical property and bending stability compared with other flexible circuits made by existing techniques. Furthermore, practical applications of the PFP circuits are demonstrated.
NASA Astrophysics Data System (ADS)
Kabrein, H.; Hariri, A.; Leman, A. M.; Noraini, N. M. R.; Yusof, M. Z. M.; Afandi, A.
2017-09-01
Heating ventilation and air conditioning system (HVAC) is very important for offices building and human health. The combining filter method was used to reduce the air pollution indoor such as that particulate matter and gases pollution that affected in health and productivity. Using particle filters in industrial HVAC systems (factories and manufacturing process) does not enough to remove all the indoor pollution. The main objective of this study is to investigate the impact of combination filters for particle and gases removal efficiency. The combining method is by using two filters (particulate filter pre-filter and carbon filter) to reduce particle matter and gases respectively. The purpose of this study is to use minimum efficiency reporting value (MERV filter) rating 13 and activated carbon filter (ACF) to remove indoor air pollution and controlling the air change rate to enhance the air quality and energy saving. It was concluded that the combination filter showed good removal efficiency of particle up to 90.76% and 89.25% for PM10 and PM2.5 respectively. The pressure drop across the filters was small compared with the high-efficiency filters. The filtration efficiency of combination filters after three months’ was better than efficiency by the new MERV filter alone.
Zarriello, Phillip J.; Breault, Robert F.; Weiskel, Peter K.
2002-01-01
The water quality of the lower Charles River is periodically impaired by combined sewer overflows (CSOs) and non-CSO stormwater runoff. This study examined the potential non-CSO load reductions of suspended solids, fecal coliform bacteria, total phosphorus, and total lead that could reasonably be achieved by implementation of stormwater best management practices, including both structural controls and systematic street sweeping. Structural controls were grouped by major physical or chemical process; these included infiltration-filtration (physical separation), biofiltration-bioretention (biological mechanisms), or detention-retention (physical settling). For each of these categories, upper and lower quartiles, median, and average removal efficiencies were compiled from three national databases of structural control performance. Removal efficiencies obtained indicated a wide range of performance. Removal was generally greatest for infiltration-filtration controls and suspended solids, and least for biofiltration-bioretention controls and fecal coliform bacteria. Street sweeping has received renewed interest as a water-quality control practice because of reported improvements in sweeper technology and the recognition that opportunities for implementing structural controls are limited in highly urbanized areas. The Stormwater Management Model that was developed by the U.S. Geological Survey for the lower Charles River Watershed was modified to simulate the effects of street sweeping in a single-family land-use basin. Constituent buildup and washoff variable values were calibrated to observed annual and storm-event loads. Once calibrated, the street sweeping model was applied to various permutations of four sweeper efficiencies and six sweeping frequencies that ranged from every day to once every 30 days. Reduction of constituent loads to the lower Charles River by the combined hypothetical practices of structural controls and street sweeping was estimated for a range of removal efficiencies because of their inherent variability and uncertainty. This range of efficiencies, with upper and lower estimates, provides reasonable bounds on the load that could be removed by the practices examined. The upper estimated load reduction from combined street sweeping and structural controls, as a percentage of the total non-CSO load entering the lower Charles River downstream of Watertown Dam, was 44 percent for suspended solids, 34 percent for total lead, 14 percent for total phosphorus, and 17 percent for fecal coliform bacteria. The lower estimated load reduction from combined street sweeping and structural controls from non-CSO sources downstream of Watertown Dam, was 14 percent for suspended solids, 11 percent for total lead, 4.9 percent for total phosphorus, and 7.5 percent for fecal coliform bacteria. Load reductions by these combined management practices can be a small as 1.4 percent for total phosphorus to about 4 percent for the other constituents if the total load above Watertown Dam is added to the load from below the dam. Although the reductions in stormwater loads to the lower Charles River from the control practices examined appear to be minor, these practices would likely provide water-quality benefits to portions of the river during those times that they are most impaired-during and immediately after storms. It should also be recognized that only direct measurements of changes in stormwater loads before and after implementation of control practices can provide definitive evidence of the beneficial effects of these practices on water-quality conditions in the lower Charles River.
NASA Astrophysics Data System (ADS)
Syngouna, Vasiliki I.; Chrysikopoulos, Constantinos V.
2012-03-01
The main objective of this study was to evaluate the combined effects of grain size and pore water velocity on the transport in water saturated porous media of three waterborne fecal indicator organisms (Escherichia coli, MS2, and ΦX174) in laboratory-scale columns packed with clean quartz sand. Three different grain sizes and three pore water velocities were examined and the attachment behavior of Escherichia coli, MS2, and ΦX174 onto quartz sand was evaluated. The mass recoveries of the biocolloids examined were shown to be highest for Escherichia coli and lowest for MS2. However, no obvious relationships between mass recoveries and water velocity or grain size could be established from the experimental results. The observed mean dispersivity values for each sand grain size were smaller for bacteria than coliphages, but higher for MS2 than ΦX174. The single collector removal and collision efficiencies were quantified using the classical colloid filtration theory. Furthermore, theoretical collision efficiencies were estimated only for E. coli by the Interaction-Force-Boundary-Layer, and Maxwell approximations. Better agreement between the experimental and Maxwell theoretical collision efficiencies were observed.
NASA Astrophysics Data System (ADS)
Syngouna, Vasiliki I.; Chrysikopoulos, Constantinos V.
2011-11-01
The main objective of this study was to evaluate the combined effects of grain size and pore water velocity on the transport in water saturated porous media of three waterborne fecal indicator organisms ( Escherichia coli, MS2, and ΦX174) in laboratory-scale columns packed with clean quartz sand. Three different grain sizes and three pore water velocities were examined and the attachment behavior of Escherichia coli, MS2, and ΦX174 onto quartz sand was evaluated. The mass recoveries of the biocolloids examined were shown to be highest for Escherichia coli and lowest for MS2. However, no obvious relationships between mass recoveries and water velocity or grain size could be established from the experimental results. The observed mean dispersivity values for each sand grain size were smaller for bacteria than coliphages, but higher for MS2 than ΦX174. The single collector removal and collision efficiencies were quantified using the classical colloid filtration theory. Furthermore, theoretical collision efficiencies were estimated only for E. coli by the Interaction-Force-Boundary-Layer, and Maxwell approximations. Better agreement between the experimental and Maxwell theoretical collision efficiencies were observed.
Removal of Inclusions from Molten Aluminum by Supergravity Filtration
NASA Astrophysics Data System (ADS)
Song, Gaoyang; Song, Bo; Yang, Zhanbing; Yang, Yuhou; Zhang, Jing
2016-12-01
A new approach to removing inclusions from aluminum melt by supergravity filtration was investigated. The molten aluminum containing MgAl2O4 spinel and coarse Al3Ti particles was isothermally filtered with different gravity coefficients, different filtering times, and various filtering temperatures under supergravity field. When the gravity coefficient G ≥ 50, the alloy samples were divided automatically into two parts: the upper residue and the lower filtered aluminum. All inclusions (MgAl2O4 and Al3Ti particles) were nearly intercepted in the upper residue by filter felt with average pore size of 44.78 μm. The removal efficiencies of oxide inclusions and Al3Ti particles exceeded 98 and 90 pct, respectively, at G ≥ 50, t = 2 minutes, T = 973 K (700 °C). Besides, the yield of purified aluminum was up to 92.1 pct at G = 600, t = 2 minutes, and T = 973 K (700 °C). The calculations of centrifugal pressure indicated that supergravity filtration could effectively overcome the pressure drop without meeting the rigorous requirement of height of molten metal, especially for using the fine-pore filter medium. Moreover, cake-mode filtration was the major mechanism of supergravity filtration of molten metal in this work.
Separation of nanoparticles: Filtration and scavenging from waste incineration plants.
Förster, Henning; Thajudeen, Thaseem; Funk, Christine; Peukert, Wolfgang
2016-06-01
Increased amounts of nanoparticles are applied in products of everyday life and despite material recycling efforts, at the end of their life cycle they are fed into waste incineration plants. This raises the question on the fate of nanoparticles during incineration. In terms of environmental impact the key question is how well airborne nanoparticles are removed by separation processes on their way to the bag house filters and by the existing filtration process based on pulse-jet cleanable fibrous filter media. Therefore, we investigate the scavenging and the filtration of metal nanoparticles under typical conditions in waste incineration plants. The scavenging process is investigated by a population balance model while the nanoparticle filtration experiments are realized in a filter test rig. The results show that depending on the particle sizes, in some cases nearly 80% of the nanoparticles are scavenged by fly ash particles before they reach the bag house filter. For the filtration step dust cakes with a pressure drop of 500Pa or higher are found to be very effective in preventing nanoparticles from penetrating through the filter. Thus, regeneration of the filter must be undertaken with care in order to guarantee highly efficient collection of particles even in the lower nanometre size regime. Copyright © 2016 Elsevier Ltd. All rights reserved.
Grey water treatment in urban slums by a filtration system: optimisation of the filtration medium.
Katukiza, A Y; Ronteltap, M; Niwagaba, C B; Kansiime, F; Lens, P N L
2014-12-15
Two uPVC columns (outer diameter 160 cm, internal diameter 14.6 cm and length 100 cm) were operated in parallel and in series to simulate grey water treatment by media based filtration at unsaturated conditions and constant hydraulic loading rates (HLR). Grey water from bathroom, laundry and kitchen activities was collected from 10 households in the Bwaise III slum in Kampala (Uganda) in separate containers, mixed in equal proportions followed by settling, prior to transferring the influent to the tanks. Column 1 was packed with lava rock to a depth of 60 cm, while column 2 was packed with lava rock (bottom 30 cm) and silica sand, which was later replaced by granular activated carbon (top 30 cm) to further investigate nutrient removal from grey water. Operating the two filter columns in series at a HLR of 20 cm/day resulted in a better effluent quality than at a higher (40 cm/day) HLR. The COD removal efficiencies by filter columns 1 and 2 in series amounted to 90% and 84% at HLR of 20 cm/day and 40 cm/day, respectively. TOC and DOC removal efficiency amounted to 77% and 71% at a HLR of 20 cm/day, but decreased to 72% and 67% at a HLR of 40 cm/day, respectively. The highest log removal of Escherichia coli, Salmonella sp. and total coliforms amounted to 3.68, 3.50 and 3.95 at a HLR of 20 cm/day respectively. The overall removal of pollutants increased with infiltration depth, with the highest pollutant removal efficiency occurring in the top 15 cm layer. Grey water pre-treatment followed by double filtration using coarse and fine media has the potential to reduce the grey water pollution load in slum areas by more than 60%. Copyright © 2014 Elsevier Ltd. All rights reserved.
Gel filtration applied to the study of lipases and other esterases
Downey, W. K.; Andrews, P.
1965-01-01
1. Sephadex G-100 and G-200 gel-filtration columns were calibrated for molecular-weight estimation with proteins of known molecular weights, and used to study the composition of several lipase or esterase preparations. 2. Enzymes from cow's milk, rat adipose tissue and pig pancreas were detected in the column effluents by their ability to liberate free acid from emulsified tributyrin at pH 8·5. 3. Four tributyrinases were detected in preparations from individual cow's milks. Molecular weights 62000, 75000 and 112000 were estimated for three of them, but although the fourth may be of unusually low molecular weight an estimate was not possible. 4. Extracts of rat adipose tissue apparently contained six tributyrinases (molecular weights 39000, 47000, 55000, 68000, 75000 and 200000) but the relative amounts of these enzymes varied widely from rat to rat. 5. Tributyrinase activity in juice expressed from pig pancreatic tissue was due mainly to one enzyme (molecular weight 42000). On the other hand, activity in extracts of acetone-dried pancreas was confined to material of molecular weight > 106, which may be an aggregated form of the lower-molecular-weight enzyme. 6. Activity in fractionated wheat-germ extracts was assayed with emulsified triacetin substrate, and was evidently due to one enzyme (molecular weight 51000). 7. Some problems arising in the application of gel filtration to the study of lipase–esterase systems were indicated. PMID:14340054
Vulnerability of bank filtration systems to climate change.
Sprenger, C; Lorenzen, G; Hülshoff, I; Grützmacher, G; Ronghang, M; Pekdeger, A
2011-01-15
Bank filtration (BF) is a well established and proven natural water treatment technology, where surface water is infiltrated to an aquifer through river or lake banks. Improvement of water quality is achieved by a series of chemical, biological and physical processes during subsurface passage. This paper aims at identifying climate sensitive factors affecting bank filtration performance and assesses their relevance based on hypothetical 'drought' and 'flood' climate scenarios. The climate sensitive factors influencing water quantity and quality also have influence on substance removal parameters such as redox conditions and travel time. Droughts are found to promote anaerobic conditions during bank filtration passage, while flood events can drastically shorten travel time and cause breakthrough of pathogens, metals, suspended solids, DOC and organic micropollutants. The study revealed that only BF systems comprising an oxic to anoxic redox sequence ensure maximum removal efficiency. The storage capacity of the banks and availability of two source waters renders BF for drinking water supply less vulnerable than surface water or groundwater abstraction alone. Overall, BF is vulnerable to climate change although anthropogenic impacts are at least as important. Copyright © 2010 Elsevier B.V. All rights reserved.
Sultan, Zuraimi M
2007-05-01
Although many studies have reported calculations of outdoor particulate matter (PM) associated externalities using ambient data, there is little information on the role buildings, their ventilation and filtration play. This study provides the framework to evaluate the health risk and cost reduction of building, ventilation and filtration strategies from outdoor PM pollution on a nationwide level and applied it to a case study in Singapore. Combining Indoor Air Quality (IAQ) and time weighted exposure models, with established concentration-response functions and monetary valuation methods, mortality and morbidity effects of outdoor PM on the population of Singapore under different building, ventilation and filtration strategies were estimated. Different interventions were made to compare the effects from the current building conditions. The findings demonstrate that building protection effect reduced approximately half the attributable health cases amounting to US$17.7 billion due to PM pollution when compared to levels computed using outdoor data alone. For residential buildings, nationwide adoption of natural ventilation from current state is associated with 28% higher cases of mortality and 13 to 38% higher cases for different morbidities, amounting to US$6.7 billion. The incurred cost is negligible compared to energy costs of air-conditioning. However, nationwide adoption of closed residence and air-conditioning are associated with outcomes including fewer mortality (10 and 6% respectively), fewer morbidities (8 and 4% respectively) and economic savings of US$1.5 and 0.9 billion respectively. The related savings were about a factor of 9 the energy cost for air-conditioning. Nationwide adoption of mechanical ventilation and filtration from current natural ventilation in schools is associated with fewer asthma hospital admissions and exacerbations; although the economic impact is not substantial. Enhanced workplace filtration reduces the mortality and morbidity cases by 14 and 13% respectively amounting to savings of up to US$2.4 billion. The huge costs savings are comparable to the average worker salary and insignificant to energy, installation and rental cost. Despite uncertainty about accurate benefits, this study shows that health and economic gain via different building, ventilation and filtration designs in minimizing ingress of outdoor PM applied to a nationwide scale can be very large. Importantly, the results suggest that PM associated externalities and legislative efforts should not only focus on ambient PM reduction policies but also include building-informed decisions.
Evolution of deep-bed filtration of engine exhaust particulates with trapped mass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viswanathan, Sandeep; Rothamer, David A.; Foster, David E.
Micro-scale filtration experiments were performed on cordierite filter samples using particulate matter (PM) generated by a spark-ignition direct-injection (SIDI) engine fueled with tier II EEE certification gasoline. Size-resolved mass and number concentrations were obtained from several engine operating conditions. The resultant mass-mobility relationships showed weak dependence on the operating condition. An integrated particle size distribution (IPSD) method was used estimate the PM mass concentration in the exhaust stream from the SIDI engine and a heavy duty diesel (HDD) engine. The average estimated mass concentration between all conditions was ~77****** % of the gravimetric measurements performed on Teflon filters. Despite themore » relatively low elemental carbon fraction (~0.4 to 0.7), the IPSD mass for stoichiometric SIDI exhaust was ~83±38 % of the gravimetric measurement. Identical cordierite filter samples with properties representative of diesel particulate filters were sequentially loaded with PM from the different SIDI engine operating conditions, in order of increasing PM mass concentration. Simultaneous particle size distribution measurements upstream and downstream of the filter sample were used to evaluate filter performance evolution and the instantaneous trapped mass within the filter for two different filter face velocities. The evolution of filtration performance for the different samples was sensitive only to trapped mass, despite using PM from a wide range of operating conditions. Higher filtration velocity resulted in a more rapid shift in the most penetrating particle size towards smaller mobility diameters.« less
Reducing indoor air pollutants with air filtration units in wood stove homes.
McNamara, Marcy L; Thornburg, Jonathon; Semmens, Erin O; Ward, Tony J; Noonan, Curtis W
2017-08-15
Biomass burning has been shown to be a major source of poor indoor air quality (IAQ) in developing and higher income countries across the world. Specifically, wood burning for cooking and heating contributes to high indoor concentrations of fine (particles with aerodynamic diameters<2.5μm; PM 2.5 ) and coarse (particles with aerodynamic diameters <10μm and >2.5μm; PMc) particulate matter. Endotoxin, predominantly found within the coarse fraction of airborne particulate matter, is associated with proinflammatory effects and adverse outcomes among susceptible populations. The aim of this study was to assess the efficacy of air filter interventions in reducing indoor PM 2.5 , PMc, and PMc-associated endotoxin concentrations in homes using a wood stove for primary heating. Homes (n=48) were randomized to receive in-room air filtration units with either a high efficiency filter (i.e. active) or a lower efficiency fiberglass filter (i.e., placebo). The active filter intervention showed a 66% reduction in indoor PM 2.5 concentrations (95% CI: 42.2% to 79.7% reduction) relative to the placebo intervention. Both the active and the placebo filters were effective in substantially reducing indoor concentrations of PMc (63.3% and 40.6% average reduction for active and placebo filters, respectively) and PMc-associated endotoxin concentrations (91.8% and 80.4% average reductions, respectively). These findings support the use of high efficiency air filtration units for reducing indoor PM 2.5 in homes using a wood stove for primary heating. We also discovered that using lower efficiency, lower cost filter alternatives can be effective for reducing PMc and airborne endotoxin in homes burning biomass fuel. Copyright © 2017. Published by Elsevier B.V.
Optimization of an enhanced ceramic micro-filter for concentrating E.coli in water
NASA Astrophysics Data System (ADS)
Zhang, Yushan; Guo, Tianyi; Xu, Changqing; Hong, Lingcheng
2017-02-01
Recently lower limit of detection (LOD) is necessary for rapid bacteria detection and analysis applications in clinical practices and daily life. A critical pre-conditioning step for these applications is bacterial concentration, especially for low level of pathogens. Sample volume can be largely reduced with an efficient pre-concentration process. Some approaches such as hollow-fiber ultra-filtration and electrokinetic technique have been applied to bacterial concentration. Since none of these methods can provide a concentrating method with a stable recovery efficiency, bacterial concentration still remains challenging Ceramic micro- filter can be used to concentrate the bacteria but the cross flow system keeps the bacteria in suspension. Similar harvesting bacteria using ultra-filtration showed an average recovery efficiency of 43% [1] and other studies achieved recovery rates greater than 50% [2]. In this study, an enhanced ceramic micro-filter with 0.14 μm pore size was proposed and demonstrated to optimize the concentration of E.coli. A high recovery rate (mean value >90%) and a high volumetric concentration ratio (>100) were achieved. Known quantities (104 to 106 CFU/ml) of E.coli cells were spiked to different amounts of phosphate buffered saline (0.1 to 1 L), and then concentrated to a final retentate of 5 ml to 10 ml. An average recovery efficiency of 95.3% with a standard deviation of 5.6% was achieved when the volumetric con- centration ratio was 10. No significant recovery rate loss was indicated when the volumetric concentration ratio reached up to 100. The effects of multiple parameters on E.coli recovery rate were also studied. The obtained results indicated that the optimized ceramic micro- filtration system can successfully concentrate E.coli cells in water with an average recovery rate of 90.8%.
Yuruk, Emrah; Binbay, Murat; Ozgor, Faruk; Erbin, Akif; Berberoglu, Yalcin; Muslumanoglu, Ahmet Y
2014-12-01
To evaluate the outcomes of kidney stone treatment using flexible ureterorenoscopy (f-URS) among patients with chronic kidney disease (CKD). Data of patients who underwent f-URS between January 2009 and December 2012 were collected. Patients were staged according to estimated glomerular filtration rate. Patients with stage ≥ 3 were accepted as having CKD (study group). These patients were matched with a group of patients without CKD (control group). Operative characteristics, complication rates, and third-month success rates were compared. Overall, 339 patients underwent f-URS and 62 (18.28%) had CKD. Control group constituted of 87 patients. Having a solitary kidney (17.4% vs 3.5%; P = .003) and history of stone intervention (51.6% vs 23%; P = .001) were more common in the CKD group. Similarly, access sheath was more commonly used among patients with CKD (87.1% vs 70.22%; P = .015). Both perioperative (19.35% vs 19.54; P = .372) and postoperative (22.6% vs 16.1%; P = .214) complication rates were similar in patients with and without CKD. Hospitalization time was 25.70 ± 25.62 and 24.5 ± 25 hours (P = .871) for patients with and without CKD, respectively. Although mean third postoperative estimated glomerular filtration rate of patients with CKD did not change significantly (48.16 ± 8.72 vs 49.08 ± 9.26; P = .431), CKD stage of 13 patients shifted from 3 to 2. At the third postoperative month, stone free rate in patients with and without CKD was 87.1% vs 86.2% (P = .875). f-URS is a safe and effective procedure in patients with CKD and it is associated with improved overall kidney function. Copyright © 2014 Elsevier Inc. All rights reserved.
Shirasaki, N; Matsushita, T; Matsui, Y; Yamashita, R
2018-02-01
Here, we evaluated the removal of three representative human enteric viruses - adenovirus (AdV) type 40, coxsackievirus (CV) B5, and hepatitis A virus (HAV) IB - and one surrogate of human caliciviruses - murine norovirus (MNV) type 1 - by coagulation-rapid sand filtration, using water samples from eight water sources for drinking water treatment plants in Japan. The removal ratios of a plant virus (pepper mild mottle virus; PMMoV) and two bacteriophages (MS2 and φX174) were compared with the removal ratios of human enteric viruses to assess the suitability of PMMoV, MS2, and φX174 as surrogates for human enteric viruses. The removal ratios of AdV, CV, HAV, and MNV, evaluated via the real-time polymerase chain reaction (PCR) method, were 0.8-2.5-log 10 when commercially available polyaluminum chloride (PACl, basicity 1.5) and virgin silica sand were used as the coagulant and filter medium, respectively. The type of coagulant affected the virus removal efficiency, but the age of silica sand used in the rapid sand filtration did not. Coagulation-rapid sand filtration with non-sulfated, high-basicity PACls (basicity 2.1 or 2.5) removed viruses more efficiently than the other aluminum-based coagulants. The removal ratios of MS2 were sometimes higher than those of the three human enteric viruses and MNV, whereas the removal ratios of φX174 tended to be smaller than those of the three human enteric viruses and MNV. In contrast, the removal ratios of PMMoV were similar to and strongly correlated with those of the three human enteric viruses and MNV. Thus, PMMoV appears to be a suitable surrogate for human enteric viruses for the assessment of the efficacy of coagulation-rapid sand filtration to remove viruses. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pan, Lin-Men; Huang, Min-Yan; Guo, Li-Wei
2012-11-01
To study the measures for preventing and controlling the pollution of aqueous extract of Astragali Radix proceeded with inorganic ceramic membrane micro-filtration, in order to find effective measures for preventing and controlling the membrane pollution. The resistance distribution, polymer removal and changes in physical and chemical parameters of the zirconium oxide film of different pore diameters were determined to analyze the state or location of pollutants as well as the regularity of formation. Meanwhile, recoil and ultrasonic physical measures were adopted to strengthen the membrane process, in order to explore the methods for preventing and controlling the membrane pollution. When 0.2 microm of ZrO2 micro-filtrated aqueous extract of Astragali Radix, the rate of pollution was as high as 44.9%. The hole blocking resistance and the concentration polarization resistance were the main filtration resistances, while the surface deposit resistance decreased with the increase in the membrane's hold diameter; after micro-filtration, the liquid turbidity significantly reduced, with slight changes in both pH and viscosity. The 0.2 microm ZrO2 micro-filtration membrane performed better than the 0.05 microm pore size membrane in terms of conductivity. The 0. 2 microm and 0.05 microm pore diameter membranes showed better performance in the removal of pectin. The ultrasonic measure to strengthen membranes is more suitable to this system, with a flux rate up by 41.7%. The membrane optimization process adopts appropriate measures for preventing and controlling the membrane pollution, in order to reduce the membrane pollution, recover membrane performance and increase filtration efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rizzo, Jeffrey J.
2010-04-30
The Wabash gasification facility, owned and operated by sgSolutions LLC, is one of the largest single train solid fuel gasification facilities in the world capable of transforming 2,000 tons per day of petroleum coke or 2,600 tons per day of bituminous coal into synthetic gas for electrical power generation. The Wabash plant utilizes Phillips66 proprietary E-Gas (TM) Gasification Process to convert solid fuels such as petroleum coke or coal into synthetic gas that is fed to a combined cycle combustion turbine power generation facility. During plant startup in 1995, reliability issues were realized in the gas filtration portion of themore » gasification process. To address these issues, a slipstream test unit was constructed at the Wabash facility to test various filter designs, materials and process conditions for potential reliability improvement. The char filtration slipstream unit provided a way of testing new materials, maintenance procedures, and process changes without the risk of stopping commercial production in the facility. It also greatly reduced maintenance expenditures associated with full scale testing in the commercial plant. This char filtration slipstream unit was installed with assistance from the United States Department of Energy (built under DOE Contract No. DE-FC26-97FT34158) and began initial testing in November of 1997. It has proven to be extremely beneficial in the advancement of the E-Gas (TM) char removal technology by accurately predicting filter behavior and potential failure mechanisms that would occur in the commercial process. After completing four (4) years of testing various filter types and configurations on numerous gasification feed stocks, a decision was made to investigate the economic and reliability effects of using a particulate removal gas cyclone upstream of the current gas filtration unit. A paper study had indicated that there was a real potential to lower both installed capital and operating costs by implementing a char cyclonefiltration hybrid unit in the E-Gas (TM) gasification process. These reductions would help to keep the E-Gas (TM) technology competitive among other coal-fired power generation technologies. The Wabash combined cyclone and gas filtration slipstream test program was developed to provide design information, equipment specification and process control parameters of a hybrid cyclone and candle filter particulate removal system in the E-Gas (TM) gasification process that would provide the optimum performance and reliability for future commercial use. The test program objectives were as follows: 1. Evaluate the use of various cyclone materials of construction; 2. Establish the optimal cyclone efficiency that provides stable long term gas filter operation; 3. Determine the particle size distribution of the char separated by both the cyclone and candle filters. This will provide insight into cyclone efficiency and potential future plant design; 4. Determine the optimum filter media size requirements for the cyclone-filtration hybrid unit; 5. Determine the appropriate char transfer rates for both the cyclone and filtration portions of the hybrid unit; 6. Develop operating procedures for the cyclone-filtration hybrid unit; and, 7. Compare the installed capital cost of a scaled-up commercial cyclone-filtration hybrid unit to the current gas filtration design without a cyclone unit, such as currently exists at the Wabash facility.« less
... Testing Epstein-Barr Virus (EBV) Antibody Tests Erythrocyte Sedimentation Rate (ESR) Erythropoietin Estimated Glomerular Filtration Rate (eGFR) ... Available online at http://health.lifestyle.yahoo.ca/channel_section_details.asp?text_id=1364&channel_id= ...
Alternatives for the Bedside Schwartz Equation to Estimate Glomerular Filtration Rate in Children.
Pottel, Hans; Dubourg, Laurence; Goffin, Karolien; Delanaye, Pierre
2018-01-01
The bedside Schwartz equation has long been and still is the recommended equation to estimate glomerular filtration rate (GFR) in children. However, this equation is probably best suited to estimate GFR in children with chronic kidney disease (reduced GFR) but is not optimal for children with GFR >75 mL/min/1.73 m 2 . Moreover, the Schwartz equation requires the height of the child, information that is usually not available in the clinical laboratory. This makes automatic reporting of estimated glomerular filtration rate (eGFR) along with serum creatinine impossible. As the majority of children (even children referred to nephrology clinics) have GFR >75 mL/min/1.73 m 2 , it might be interesting to evaluate possible alternatives to the bedside Schwartz equation. The pediatric form of the Full Age Spectrum (FAS) equation offers an alternative to Schwartz, allowing automatic reporting of eGFR since height is not necessary. However, when height is involved in the FAS equation, the equation is essentially equal to the Schwartz equation for children, but there are large differences for adolescents. Combining standardized biomarkers increases the prediction performance of eGFR equations for children, reaching P10 ≈ 45% and P30 ≈ 90%. There are currently good and simple alternatives to the bedside Schwartz equation, but the more complex equations combining serum creatinine, serum cystatin C, and height show the highest accuracy and precision. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Torres-Sánchez, M J; Ávila-Barranco, E; Esteban de la Rosa, R J; Fernández-Castillo, R; Esteban, M A; Carrero, J J; García-Valverde, M; Bravo-Soto, J A
2016-03-01
To determine in patients with autosomal dominant polycystic kidney disease the relationship between total renal volume (the sum of both kidneys, TRV) as measured by magnetic resonance and renal function; and its behaviour according to sex and the presence of arterial hypertension, hypercholesterolaemia and hyperglycemia. Cross-sectional study including patients with autosomal dominant polycystic kidney disease who underwent periodic reviews at Nephrology external consultations at Hospital de las Nieves de Granada, and who underwent an magnetic resonance to estimate renal volume between January 2008 and March 2011. We evaluated 67 patients (59.7% women, average age of 48±14.4 years) and found a significant positive association between TRV and serum creatinine or urea, which was reversed compared with estimated glomerular filtration by MDRD-4 and Cockcroft-Gault. Women showed an average serum creatinine level and a significantly lower TRV level compared with males. Subgroups affected by arterial hypertension and hyperuricemia presented average values for serum creatinine and urea, higher for TRV and lower for estimated glomerular filtration. The hypercholesterolaemia subgroup showed higher average values for urea and lower for estimated glomerular filtration, without detecting significant differences compared with TRV. The volume of polycystic kidneys measured by magnetic resonance is associated with renal function, and can be useful as a complementary study to monitor disease progression. The presence of arterial hypertension, hyperuricemia or hypercholesterolaemia is associated with a poorer renal function. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Medicina Interna (SEMI). All rights reserved.
Henriksson, Martin; Palmer, Stephen; Chen, Ruoling; Damant, Jacqueline; Fitzpatrick, Natalie K; Abrams, Keith; Hingorani, Aroon D; Stenestrand, Ulf; Janzon, Magnus; Feder, Gene; Keogh, Bruce; Shipley, Martin J; Kaski, Juan-Carlos; Timmis, Adam; Sculpher, Mark
2010-01-01
Objective To determine the effectiveness and cost effectiveness of using information from circulating biomarkers to inform the prioritisation process of patients with stable angina awaiting coronary artery bypass graft surgery. Design Decision analytical model comparing four prioritisation strategies without biomarkers (no formal prioritisation, two urgency scores, and a risk score) and three strategies based on a risk score using biomarkers: a routinely assessed biomarker (estimated glomerular filtration rate), a novel biomarker (C reactive protein), or both. The order in which to perform coronary artery bypass grafting in a cohort of patients was determined by each prioritisation strategy, and mean lifetime costs and quality adjusted life years (QALYs) were compared. Data sources Swedish Coronary Angiography and Angioplasty Registry (9935 patients with stable angina awaiting coronary artery bypass grafting and then followed up for cardiovascular events after the procedure for 3.8 years), and meta-analyses of prognostic effects (relative risks) of biomarkers. Results The observed risk of cardiovascular events while on the waiting list for coronary artery bypass grafting was 3 per 10 000 patients per day within the first 90 days (184 events in 9935 patients). Using a cost effectiveness threshold of £20 000-£30 000 (€22 000-€33 000; $32 000-$48 000) per additional QALY, a prioritisation strategy using a risk score with estimated glomerular filtration rate was the most cost effective strategy (cost per additional QALY was <£410 compared with the Ontario urgency score). The impact on population health of implementing this strategy was 800 QALYs per 100 000 patients at an additional cost of £245 000 to the National Health Service. The prioritisation strategy using a risk score with C reactive protein was associated with lower QALYs and higher costs compared with a risk score using estimated glomerular filtration rate. Conclusion Evaluating the cost effectiveness of prognostic biomarkers is important even when effects at an individual level are small. Formal prioritisation of patients awaiting coronary artery bypass grafting using a routinely assessed biomarker (estimated glomerular filtration rate) along with simple, routinely collected clinical information was cost effective. Prioritisation strategies based on the prognostic information conferred by C reactive protein, which is not currently measured in this context, or a combination of C reactive protein and estimated glomerular filtration rate, is unlikely to be cost effective. The widespread practice of using only implicit or informal means of clinically ordering the waiting list may be harmful and should be replaced with formal prioritisation approaches. PMID:20085988
Determination of glomerular function in advanced renal failure.
Manz, F; Alatas, H; Kochen, W; Lutz, P; Rebien, W; Schärer, K
1977-01-01
In 15 children with advanced chronic renal failure, glomerular filtration rate was determined by different methods. Inulin clearance correlated well with the mean of creatinine and urea clearance, and also with 51-chromium edetic acid (EDTA) clearance measured over 24 hours. The absolute values of creatinine clearance and of 51Cr-EDTA clearance measured up to 8 hours were higher than inulin clearance. In advanced renal failure both the 51Cr-EDTA clearance measured over 24 hours, and the mean of creatinine and urea clearance, provide acceptable estimates of true glomerular filtration rate. PMID:411426
Methodology for Modeling the Microbial Contamination of Air Filters
Joe, Yun Haeng; Yoon, Ki Young; Hwang, Jungho
2014-01-01
In this paper, we propose a theoretical model to simulate microbial growth on contaminated air filters and entrainment of bioaerosols from the filters to an indoor environment. Air filter filtration and antimicrobial efficiencies, and effects of dust particles on these efficiencies, were evaluated. The number of bioaerosols downstream of the filter could be characterized according to three phases: initial, transitional, and stationary. In the initial phase, the number was determined by filtration efficiency, the concentration of dust particles entering the filter, and the flow rate. During the transitional phase, the number of bioaerosols gradually increased up to the stationary phase, at which point no further increase was observed. The antimicrobial efficiency and flow rate were the dominant parameters affecting the number of bioaerosols downstream of the filter in the transitional and stationary phase, respectively. It was found that the nutrient fraction of dust particles entering the filter caused a significant change in the number of bioaerosols in both the transitional and stationary phases. The proposed model would be a solution for predicting the air filter life cycle in terms of microbiological activity by simulating the microbial contamination of the filter. PMID:24523908
Further evaluation of the NWF filter for the purification of Plasmodium vivax-infected erythrocytes.
Li, Jiangyan; Tao, Zhiyong; Li, Qian; Brashear, Awtum; Wang, Ying; Xia, Hui; Fang, Qiang; Cui, Liwang
2017-05-17
Isolation of Plasmodium-infected red blood cells (iRBCs) from clinical blood samples is often required for experiments, such as ex vivo drug assays, in vitro invasion assays and genome sequencing. Current methods for removing white blood cells (WBCs) from malaria-infected blood are time-consuming or costly. A prototype non-woven fabric (NWF) filter was developed for the purification of iRBCs, which showed great efficiency for removing WBCs in a pilot study. Previous work was performed with prototype filters optimized for processing 5-10 mL of blood. With the commercialization of the filters, this study aims to evaluate the efficiency and suitability of the commercial NWF filter for the purification of Plasmodium vivax-infected RBCs in smaller volumes of blood and to compare its performance with that of Plasmodipur ® filters. Forty-three clinical P. vivax blood samples taken from symptomatic patients attending malaria clinics at the China-Myanmar border were processed using the NWF filters in a nearby field laboratory. The numbers of WBCs and iRBCs and morphology of P. vivax parasites in the blood samples before and after NWF filtration were compared. The viability of P. vivax parasites after filtration from 27 blood samples was examined by in vitro short-term culture. In addition, the effectiveness of the NWF filter for removing WBCs was compared with that of the Plasmodipur ® filter in six P. vivax blood samples. Filtration of 1-2 mL of P. vivax-infected blood with the NWF filter removed 99.68% WBCs. The densities of total iRBCs, ring and trophozoite stages before and after filtration were not significantly different (P > 0.05). However, the recovery rates of schizont- and gametocyte-infected RBCs, which were minor parasite stages in the clinical samples, were relatively low. After filtration, the P. vivax parasites did not show apparent morphological changes. Culture of 27 P. vivax-infected blood samples after filtration showed that parasites successfully matured into the schizont stage. The WBC removal rates and iRBC recovery rates were not significantly different between the NWF and Plasmodipur ® filters (P > 0.05). When tested with 1-2 mL of P. vivax-infected blood, the NWF filter could effectively remove WBCs and the recovery rates for ring- and trophozoite-iRBCs were high. P. vivax parasites after filtration could be successfully cultured in vitro to reach maturity. The performance of the NWF and Plasmodipur ® filters for removing WBCs and recovering iRBCs was comparable.
NASA Astrophysics Data System (ADS)
Amirnasr, Elham
It is widely recognized that nonwoven basis weight non-uniformity affects various properties of nonwovens. However, few studies can be found in this topic. The development of uniformity definition and measurement methods and the study of their impact on various web properties such as filtration properties and air permeability would be beneficial both in industrial applications and in academia. They can be utilized as a quality control tool and would provide insights about nonwoven behaviors that cannot be solely explained by average values. Therefore, for quantifying nonwoven web basis weight uniformity we purse to develop an optical analytical tool. The quadrant method and clustering analysis was utilized in an image analysis scheme to help define "uniformity" and its spatial variation. Implementing the quadrant method in an image analysis system allows the establishment of a uniformity index that can be used to quantify the degree of uniformity. Clustering analysis has also been modified and verified using uniform and random simulated images with known parameters. Number of clusters and cluster properties such as cluster size, member and density was determined. We also utilized this new measurement method to evaluate uniformity of nonwovens produced with different processes and investigated impacts of uniformity on filtration and permeability. The results of quadrant method shows that uniformity index computed from quadrant method demonstrate a good range for non-uniformity of nonwoven webs. Clustering analysis is also been applied on reference nonwoven with known visual uniformity. From clustering analysis results, cluster size is promising to be used as uniformity parameter. It is been shown that non-uniform nonwovens has provide lager cluster size than uniform nonwovens. It was been tried to find a relationship between web properties and uniformity index (as a web characteristic). To achieve this, filtration properties, air permeability, solidity and uniformity index of meltblown and spunbond samples was measured. Results for filtration test show some deviation between theoretical and experimental filtration efficiency by considering different types of fiber diameter. This deviation can occur due to variation in basis weight non-uniformity. So an appropriate theory is required to predict the variation of filtration efficiency with respect to non-uniformity of nonwoven filter media. And the results for air permeability test showed that uniformity index determined by quadrant method and measured properties have some relationship. In the other word, air permeability decreases as uniformity index on nonwoven web increase.
Effect of ozonation on the removal of cyanobacterial toxins during drinking water treatment.
Hoeger, Stefan J; Dietrich, Daniel R; Hitzfeld, Bettina C
2002-01-01
Water treatment plants faced with toxic cyanobacteria have to be able to remove cyanotoxins from raw water. In this study we investigated the efficacy of ozonation coupled with various filtration steps under different cyanobacterial bloom conditions. Cyanobacteria were ozonated in a laboratory-scale batch reactor modeled on a system used by a modern waterworks, with subsequent activated carbon and sand filtration steps. The presence of cyanobacterial toxins (microcystins) was determined using the protein phosphatase inhibition assay. We found that ozone concentrations of at least 1.5 mg/L were required to provide enough oxidation potential to destroy the toxin present in 5 X 10(5 )Microcystis aeruginosa cells/mL [total organic carbon (TOC), 1.56 mg/L]. High raw water TOC was shown to reduce the efficiency of free toxin oxidation and destruction. In addition, ozonation of raw waters containing high cyanobacteria cell densities will result in cell lysis and liberation of intracellular toxins. Thus, we emphasize that only regular and simultaneous monitoring of TOC/dissolved organic carbon and cyanobacterial cell densities, in conjunction with online residual O(3) concentration determination and efficient filtration steps, can ensure the provision of safe drinking water from surface waters contaminated with toxic cyanobacterial blooms. PMID:12417484
Bandak, Ghassan; Sang, Yingying; Gasparini, Alessandro; Chang, Alex R; Ballew, Shoshana H; Evans, Marie; Arnlov, Johan; Lund, Lars H; Inker, Lesley A; Coresh, Josef; Carrero, Juan-Jesus; Grams, Morgan E
2017-07-19
Concerns about hyperkalemia limit the use of angiotensin-converting enzyme inhibitors (ACE-I) and angiotensin receptor blockers (ARBs), but guidelines conflict regarding potassium-monitoring protocols. We quantified hyperkalemia monitoring and risks after ACE-I/ARB initiation and developed and validated a hyperkalemia susceptibility score. We evaluated 69 426 new users of ACE-I/ARB therapy in the Stockholm Creatinine Measurements (SCREAM) project with medication initiation from January 1, 2007 to December 31, 2010, and follow-up for 1 year thereafter. Three fourths (76%) of SCREAM patients had potassium checked within the first year. Potassium >5 and >5.5 mmol/L occurred in 5.6% and 1.7%, respectively. As a comparison, we propensity-matched new ACE-I/ARB users to 20 186 new β-blocker users in SCREAM: 64% had potassium checked. The occurrence of elevated potassium levels was similar between new β-blocker and ACE-I/ARB users without kidney disease; only at estimated glomerular filtration rate <60 mL/min per 1.73 m 2 were risks higher among ACE-I/ARB users. We developed a hyperkalemia susceptibility score that incorporated estimated glomerular filtration rate, baseline potassium level, sex, diabetes mellitus, heart failure, and the concomitant use of potassium-sparing diuretics in new ACE-I/ARB users; this score accurately predicted 1-year hyperkalemia risk in the SCREAM cohort (area under the curve, 0.845, 95% CI: 0.840-0.869) and in a validation cohort from the US-based Geisinger Health System (N=19 524; area under the curve, 0.818, 95% CI: 0.794-0.841), with good calibration. Hyperkalemia within the first year of ACE-I/ARB therapy was relatively uncommon among people with estimated glomerular filtration rate >60 mL/min per 1.73 m 2 , but rates were much higher with lower estimated glomerular filtration rate. Use of the hyperkalemia susceptibility score may help guide laboratory monitoring and prescribing strategies. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Masi, Marco; Moeini, Seyed Arash; Boari, Angela; Cimmino, Alessio; Vurro, Maurizio; Evidente, Antonio
2018-07-01
Cavoxin is a tetrasubstituted phytotoxic chalcone and cavoxone is the corresponding chroman-4-one, both produced in vitro by Phoma cava, a fungus isolated from chestnut. Cavoxin showed biofungicide potential against fungal species responsible for food moulding. Therefore, cavoxin has potential to be incorporated into biopolymer to generate 'intelligent food packaging'. To reach this objective, large-scale production of cavoxin by P. cava fermentation needs to be optimized. A rapid and efficient method for cavoxin analysis, as well as of cavoxone, in the fungal culture filtrates and the corresponding organic extracts is the first experimental step. Thus, a HPLC method was developed and applied to quantify cavoxin and cavoxone production in two different fungal culture conditions. The analysis proved that cavoxin production in stirred culture filtrates is significantly higher than in static ones.
Ludwig, T; Kern, P; Bongards, M; Wolf, C
2011-01-01
The optimization of relaxation and filtration times of submerged microfiltration flat modules in membrane bioreactors used for municipal wastewater treatment is essential for efficient plant operation. However, the optimization and control of such plants and their filtration processes is a challenging problem due to the underlying highly nonlinear and complex processes. This paper presents the use of genetic algorithms for this optimization problem in conjunction with a fully calibrated simulation model, as computational intelligence methods are perfectly suited to the nonconvex multi-objective nature of the optimization problems posed by these complex systems. The simulation model is developed and calibrated using membrane modules from the wastewater simulation software GPS-X based on the Activated Sludge Model No.1 (ASM1). Simulation results have been validated at a technical reference plant. They clearly show that filtration process costs for cleaning and energy can be reduced significantly by intelligent process optimization.
Recent Trends in Nanofibrous Membranes and Their Suitability for Air and Water Filtrations
Balamurugan, Ramalingam; Sundarrajan, Subramanian; Ramakrishna, Seeram
2011-01-01
In recent decades, engineered membranes have become a viable separation technology for a wide range of applications in environmental, food and biomedical fields. Membranes are now competitive compared to conventional techniques such as adsorption, ion exchangers and sand filters. The main advantage of membrane technology is the fact that it works without the addition of any chemicals, with relatively high efficiency and low energy consumption with well arranged process conductions. Hence they are widely utilized in biotechnology, food and drink manufacturing, air filtration and medical uses such as dialysis for kidney failure patients. Membranes from nanofibrous materials possess high surface area to volume ratio, fine tunable pore sizes and their ease of preparation prompted both industry and academic researchers to study their use in many applications. In this paper, modern concepts and current research progress on various nanofibrous membranes, such as water and air filtration media, are presented. PMID:24957734
DOE Office of Scientific and Technical Information (OSTI.GOV)
Landkamer, Lee L.; Harvey, Ronald W.; Scheibe, Timothy D.
A new colloid transport model is introduced that is conceptually simple but captures the essential features of complicated attachment and detachment behavior of colloids when conditions of secondary minimum attachment exist. This model eliminates the empirical concept of collision efficiency; the attachment rate is computed directly from colloid filtration theory. Also, a new paradigm for colloid detachment based on colloid population heterogeneity is introduced. Assuming the dispersion coefficient can be estimated from tracer behavior, this model has only two fitting parameters: (1) the fraction of colloids that attach irreversibly and (2) the rate at which reversibly attached colloids leave themore » surface. These two parameters were correlated to physical parameters that control colloid transport such as the depth of the secondary minimum and pore water velocity. Given this correlation, the model serves as a heuristic tool for exploring the influence of physical parameters such as surface potential and fluid velocity on colloid transport. This model can be extended to heterogeneous systems characterized by both primary and secondary minimum deposition by simply increasing the fraction of colloids that attach irreversibly.« less
Qin, Wenjun; Dekermenjian, Manuel; Martin, Richard J
2006-08-01
Loss of filtration efficiency in a fabric filter baghouse is typically caused by bag failure, in one form or another. The degree of such failure can be as minor as a pinhole leak or as major as a fully involved baghouse fire. In some cases, local air pollution regulations or federal hazardous waste laws may require estimation of the total quantity of particulate matter released to the environment as a result of such failures. In this paper, a technique is presented for computing the dust loading in the baghouse exhaust when one or more bags have failed. The algorithm developed is shown to be an improvement over a previously published result, which requires empirical knowledge of the variation in baghouse pressure differential with bag failures. An example calculation is presented for a baghouse equipped with 200 bags. The prediction shows that a small percentage of failed bags can cause a relatively large proportion of the gas flow to bypass the active bags, which, in turn, leads to high outlet dust loading and low overall collection efficiency from the baghouse.
Water reuse systems: A review of the principal components
Lucchetti, G.; Gray, G.A.
1988-01-01
Principal components of water reuse systems include ammonia removal, disease control, temperature control, aeration, and particulate filtration. Effective ammonia removal techniques include air stripping, ion exchange, and biofiltration. Selection of a particular technique largely depends on site-specific requirements (e.g., space, existing water quality, and fish densities). Disease control, although often overlooked, is a major problem in reuse systems. Pathogens can be controlled most effectively with ultraviolet radiation, ozone, or chlorine. Simple and inexpensive methods are available to increase oxygen concentration and eliminate gas supersaturation, these include commercial aerators, air injectors, and packed columns. Temperature control is a major advantage of reuse systems, but the equipment required can be expensive, particularly if water temperature must be rigidly controlled and ambient air temperature fluctuates. Filtration can be readily accomplished with a hydrocyclone or sand filter that increases overall system efficiency. Based on criteria of adaptability, efficiency, and reasonable cost, we recommend components for a small water reuse system.
Population based screening for chronic kidney disease: cost effectiveness study.
Manns, Braden; Hemmelgarn, Brenda; Tonelli, Marcello; Au, Flora; Chiasson, T Carter; Dong, James; Klarenbach, Scott
2010-11-08
To determine the cost effectiveness of one-off population based screening for chronic kidney disease based on estimated glomerular filtration rate. Cost utility analysis of screening with estimated glomerular filtration rate alone compared with no screening (with allowance for incidental finding of cases of chronic kidney disease). Analyses were stratified by age, diabetes, and the presence or absence of proteinuria. Scenario and sensitivity analyses, including probabilistic sensitivity analysis, were performed. Costs were estimated in all adults and in subgroups defined by age, diabetes, and hypertension. Publicly funded Canadian healthcare system. Large population based laboratory cohort used to estimate mortality rates and incidence of end stage renal disease for patients with chronic kidney disease over a five year follow-up period. Patients had not previously undergone assessment of glomerular filtration rate. Lifetime costs, end stage renal disease, quality adjusted life years (QALYs) gained, and incremental cost per QALY gained. Compared with no screening, population based screening for chronic kidney disease was associated with an incremental cost of $C463 (Canadian dollars in 2009; equivalent to about £275, €308, US $382) and a gain of 0.0044 QALYs per patient overall, representing a cost per QALY gained of $C104 900. In a cohort of 100 000 people, screening for chronic kidney disease would be expected to reduce the number of people who develop end stage renal disease over their lifetime from 675 to 657. In subgroups of people with and without diabetes, the cost per QALY gained was $C22 600 and $C572 000, respectively. In a cohort of 100 000 people with diabetes, screening would be expected to reduce the number of people who develop end stage renal disease over their lifetime from 1796 to 1741. In people without diabetes with and without hypertension, the cost per QALY gained was $C334 000 and $C1 411 100, respectively. Population based screening for chronic kidney disease with assessment of estimated glomerular filtration rate is not cost effective overall or in subgroups of people with hypertension or older people. Targeted screening of people with diabetes is associated with a cost per QALY that is similar to that accepted in other interventions funded by public healthcare systems.
Nguyen, Hoang C; Langland, Amie L; Amara, John P; Dullen, Michael; Kahn, David S; Costanzo, Joseph A
2018-04-30
Biologic manufacturing processes typically employ clarification technologies like depth filtration to remove insoluble and soluble impurities. Conventional depth filtration media used in these processes contain naturally-derived components like diatomaceous earth and cellulose. These components may introduce performance variability and contribute extractable/leachable components like beta-glucans that could interfere with limulus amebocyte lysate endotoxin assays. Recently a novel, all-synthetic depth filtration media is developed (Millistak+ ® HC Pro X0SP) that may improve process consistency, efficiency, and drug substance product quality by reducing soluble process impurities. This new media is evaluated against commercially available benchmark filters containing naturally-derived components (Millistak+ ® HC X0HC and B1HC). Using model proteins, the synthetic media demonstrates increased binding capacity of positively charged proteins (72-126 mg g -1 media) compared to conventional media (0.3-8.6 mg g -1 media); and similar values for negatively charged species (1.3-5.6 mg g -1 media). Several CHO-derived monoclonal antibodies (mAbs) or mAb-like molecules are also evaluated. The X0SP filtration performance behaves similarly to benchmarks, and exhibits improved HCP reduction (at least 50% in 55% of cases tested). X0SP filtrates contained increased silicon extractables relative to benchmarks, but these were readily removed downstream. Finally, the X0SP devices demonstrates suitable lot-to-lot robustness when specific media components are altered intentionally to manufacturing specification limits. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
El-Sayed, Ashraf S. A.; Patel, Jaimin S.; Green, Kari B.; Ali, Mohammad; Brennan, Mary; Norman, David
2015-01-01
Bacterial biological control agents (BCAs) are largely used as live products to control plant pathogens. However, due to variable environmental and ecological factors, live BCAs usually fail to produce desirable results against foliar pathogens. In this study, we investigated the potential of cell-free culture filtrates of 12 different bacterial BCAs isolated from flower beds for controlling foliar diseases caused by Alternaria spp. In vitro studies showed that culture filtrates from two isolates belonging to Bacillus subtilis and Bacillus amyloliquefaciens displayed strong efficacy and potencies against Alternaria spp. The antimicrobial activity of the culture filtrate of these two biological control agents was effective over a wider range of pH (3.0 to 9.0) and was not affected by autoclaving or proteolysis. Comparative liquid chromatography-mass spectrometry (LC-MS) analyses showed that a complex mixture of cyclic lipopeptides, primarily of the fengycin A and fengycin B families, was significantly higher in these two BCAs than inactive Bacillus spp. Interaction studies with mixtures of culture filtrates of these two species revealed additive activity, suggesting that they produce similar products, which was confirmed by LC-tandem MS analyses. In in planta pre- and postinoculation trials, foliar application of culture filtrates of B. subtilis reduced lesion sizes and lesion frequencies caused by Alternaria alternata by 68 to 81%. Taken together, our studies suggest that instead of live bacteria, culture filtrates of B. subtilis and B. amyloliquefaciens can be applied either individually or in combination for controlling foliar diseases caused by Alternaria species. PMID:26519395
NASA Astrophysics Data System (ADS)
D'Urzo, Lucia; Bayana, Hareen; Vandereyken, Jelle; Foubert, Philippe; Wu, Aiwen; Jaber, Jad; Hamzik, James
2017-03-01
Specific "killer-defects", such as micro-line-bridges are one of the key challenges in photolithography's advanced applications, such as multi-pattern. These defects generate from several sources and are very difficult to eliminate. Pointof-use filtration (POU) plays a crucial role on the mitigation, or elimination, of such defects. Previous studies have demonstrated how the contribution of POU filtration could not be studied independently from photoresists design and track hardware settings. Specifically, we investigated how an effective combination of optimized photoresist, filtration rate, filtration pressure, membrane and device cleaning, and single and multilayer filter membranes at optimized pore size could modulate the occurrence of such defects [1, 2, 3 and 4]. However, the ultimate desired behavior for POU filtration is the selective retention of defect precursor molecules contained in commercially available photoresist. This optimal behavior can be achieved via customized membrane functionalization. Membrane functionalization provides additional non-sieving interactions which combined with efficient size exclusion can selectively capture certain defect precursors. The goal of this study is to provide a comprehensive assessment of membrane functionalization applied on an asymmetric ultra-high molecular weight polyethylene (UPE) membrane at different pore size. Defectivity transferred in a 45 nm line 55 nm space (45L/55S) pattern, created through 193 nm immersion (193i) lithography with a positive tone chemically amplified resist (PT-CAR), has been evaluated on organic under-layer coated wafers. Lithography performance, such as critical dimensions (CD), line width roughness (LWR) and focus energy matrix (FEM) is also assessed.
Faisal, Nabiha; Bilodeau, Marc; Aljudaibi, Bandar; Hirch, Geri; Yoshida, Eric M; Hussaini, Trana; Ghali, Maged P; Congly, Stephen E; Ma, Mang M; Lilly, Leslie B
2018-04-04
We assessed the impact of sofosbuvir-based regimens on renal function in liver transplant recipients with recurrent hepatitis C virus and the role of renal function on the efficacy and safety of these regimens. In an expanded pan-Canadian cohort, 180 liver transplant recipients were treated with sofosbuvir-based regimens for hepatitis C virus recurrence from January 2014 to May 2015. Mean age was 58 ± 6.85 years, and 50% had F3/4 fibrosis. Patients were stratified into 4 groups based on baseline estimated glomerular filtration rate (calculated by the Modification of Diet in Renal Disease formula): < 30, 30 to 45, 46 to 60, and > 60 mL/min/173 m2. The primary outcome was posttreatment changes in renal function from baseline. Secondary outcomes included sustained virologic response at 12 weeks posttreatment and anemia-related and serious adverse events. Posttreatment renal function was improved in most patients (58%). Renal function declined in 22% of patients, which was more marked in those with estimated glomerular filtration rate < 30 mL/min/173 m2, advanced cirrhosis (P = .05), and aggressive hepatitis C virus/fibrosing cholestatic hepatitis (P < .05). High rates (80%-88%) of sustained virologic response at 12 weeks posttreatment were seen across all renal function strata. Cirrhotic patients with glomerular filtration rates < 30 mL/min/173 m2 had sustained virologic response rates at 12 weeks posttreatment comparable to the overall patient group. Rates of anemia-related adverse events and transfusion requirements increased across decreasing estimated glomerular filtration rate groups, with notably more occurrences with ribavirin-based regimens. Sofosbuvir-based regimens improved overall renal function in liver transplant recipients, with sustained virologic response, suggesting an association of subclinical hepatitis C virus-related renal disease. Sustained virologic response rates at 12 weeks posttreatment (80%-88%) were comparable regardless of baseline renal function but lower in cirrhosis.
Recirculating Air Filtration Significantly Reduces Exposure to Airborne Nanoparticles
Pui, David Y.H.; Qi, Chaolong; Stanley, Nick; Oberdörster, Günter; Maynard, Andrew
2008-01-01
Background Airborne nanoparticles from vehicle emissions have been associated with adverse effects in people with pulmonary and cardiovascular disease, and toxicologic studies have shown that nanoparticles can be more hazardous than their larger-scale counterparts. Recirculating air filtration in automobiles and houses may provide a low-cost solution to reducing exposures in many cases, thus reducing possible health risks. Objectives We investigated the effectiveness of recirculating air filtration on reducing exposure to incidental and intentionally produced airborne nanoparticles under two scenarios while driving in traffic, and while generating nanomaterials using gas-phase synthesis. Methods We tested the recirculating air filtration in two commercial vehicles when driving in traffic, as well as in a nonventilation room with a nanoparticle generator, simulating a nanomaterial production facility. We also measured the time-resolved aerosol size distribution during the in-car recirculation to investigate how recirculating air filtration affects particles of different sizes. We developed a recirculation model to describe the aerosol concentration change during recirculation. Results The use of inexpensive, low-efficiency filters in recirculation systems is shown to reduce nanoparticle concentrations to below levels found in a typical office within 3 min while driving through heavy traffic, and within 20 min in a simulated nanomaterial production facility. Conclusions Development and application of this technology could lead to significant reductions in airborne nanoparticle exposure, reducing possible risks to health and providing solutions for generating nanomaterials safely. PMID:18629306
Bakr, Ahmed Refaat; Rahaman, Md Saifur
2017-10-01
Bisphenol A is a chemical with hazardous health effects that is largely used in the manufacture of extensively used products including adhesives, plastics, powder paints, thermal paper and paper coatings, and epoxy resin, and is reported to exist in nature in an accumulative manner. In this study, both pristine and boron-doped multiwalled carbon nanotubes (MWNTs) were employed as filtration and electrochemical filtration materials, resulting in a significant removal of bisphenol A with identical performance for both MWNTs types. It was shown that the presence of salt is not critical for the greatest contaminant removal efficiency, likely due to the vital role of other electroactive species (e.g. reactive oxygen species). Near complete removal of 1 mg L -1 bisphenol A at 2 and 3 V of applied DC potentials was achieved, indicating that the electrochemical filtration process is voltage dependent at both 2 and 3 V. Increasing the residence time by 7.4 fold (from 2.0 to 14.9 s) resulted in a significant removal of bisphenol A and its toxic byproducts, up to 424 min of electrochemical filtration time at 3 V of applied potential. Based on these results, electrochemical filtration using MWNTs is considered a promising technology for the removal of the accumulative bisphenol A and the reduction of its hazardous effects in waters. Copyright © 2017. Published by Elsevier Ltd.
Noll, J.; Cecala, A.; Hummer, J.
2016-01-01
The National Institute for Occupational Safety and Health has observed that many control rooms and operator compartments in the U.S. mining industry do not have filtration systems capable of maintaining low dust concentrations in these areas. In this study at a mineral processing plant, to reduce respirable dust concentrations in a control room that had no cleaning system for intake air, a filtration and pressurization system originally designed for enclosed cabs was modified and installed. This system was composed of two filtering units: one to filter outside air and one to filter and recirculate the air inside the control room. Eighty-seven percent of submicrometer particles were reduced by the system under static conditions. This means that greater than 87 percent of respirable dust particles should be reduced as the particle-size distribution of respirable dust particles is greater than that of submicrometer particles, and filtration systems usually are more efficient in capturing the larger particles. A positive pressure near 0.02 inches of water gauge was produced, which is an important component of an effective system and minimizes the entry of particles, such as dust, into the room. The intake airflow was around 118 cfm, greater than the airflow suggested by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) for acceptable indoor air quality. After one year, the loading of the filter caused the airflow to decrease to 80 cfm, which still produces acceptable indoor air quality. Due to the loading of the filters, the reduction efficiency for submicrometer particles under static conditions increased to 94 percent from 87 percent. PMID:26834293
Enhancement of microfluidic particle separation using cross-flow filters with hydrodynamic focusing
Chiu, Yun-Yen; Huang, Chen-Kang
2016-01-01
A microfluidic chip is proposed to separate microparticles using cross-flow filtration enhanced with hydrodynamic focusing. By exploiting a buffer flow from the side, the microparticles in the sample flow are pushed on one side of the microchannels, lining up to pass through the filters. Meanwhile a larger pressure gradient in the filters is obtained to enhance separation efficiency. Compared with the traditional cross-flow filtration, our proposed mechanism has the buffer flow to create a moving virtual boundary for the sample flow to actively push all the particles to reach the filters for separation. It further allows higher flow rates. The device only requires soft lithograph fabrication to create microchannels and a novel pressurized bonding technique to make high-aspect-ratio filtration structures. A mixture of polystyrene microparticles with 2.7 μm and 10.6 μm diameters are successfully separated. 96.2 ± 2.8% of the large particle are recovered with a purity of 97.9 ± 0.5%, while 97.5 ± 0.4% of the small particle are depleted with a purity of 99.2 ± 0.4% at a sample throughput of 10 μl/min. The experiment is also conducted to show the feasibility of this mechanism to separate biological cells with the sample solutions of spiked PC3 cells in whole blood. By virtue of its high separation efficiency, our device offers a label-free separation technique and potential integration with other components, thereby serving as a promising tool for continuous cell filtration and analysis applications. PMID:26858812
EVALUATION OF FOUR NOVEL FINE PARTICULATE COLLECTION DEVICES
The report gives results of an experimental performance evaluation of four novel fine particulate control devices: the Johns-Manville Cleanable High-Efficiency Air Filtration (CHEAF) System, the APS Electrostatic Scrubber, the APS Electrotube, and the TRW Charged Droplet Scrubber...
Zhang, Shuangyi; Gitungo, Stephen; Axe, Lisa; Dyksen, John E; Raczko, Robert F
2016-11-15
With widespread occurrence of pharmaceuticals and personal care products (PPCPs) in the water cycle, their presence in source water has led to the need to better understand their treatability and removal efficiency in treatment processes. Fifteen indicator compounds were identified to represent the large number of PPCPs reported worldwide. Criteria applied to determine the indicator compounds included PPCPs widely used, observed at great frequency in aqueous systems, resistant to treatment, persistent in the environment, and representative of classes of organics. Through a pilot plant investigation to understand the optimal combination of unit process for treating PPCPs, 12 treatment trains with their additive and synergistic contributions were investigated; processes included dissolved air flotation (DAF), pre- and intermediate-ozonation with and without H 2 O 2 , intermediate chlorination, dual media filtration, granular activated carbon (GAC), and UV/H 2 O 2 . Treatment trains that achieved the greatest removals involved 1. DAF followed by intermediate ozonation, dual media filtration, and virgin GAC; 2. pre-ozonation followed by DAF, dual media filtration, and virgin GAC; and, 3. DAF (with either pre- or intermediate oxidation) followed by dual media filtration and UV/H 2 O 2 . Results revealed significant removal efficiencies for virgin GAC (preceded by DAF and intermediate ozonation) and UV/H 2 O 2 with an intensity of 700 mJ/cm 2 , where more than 12 of the compounds were removed by greater than 90%. Reduced PPCP removals were observed with virgin GAC preceded by pre-ozonation and DAF. Intermediate ozonation was more effective than using pre-ozonation, demonstrating the importance of this process targeting PPCPs after treatment of natural organic matter. Removal efficiencies of indicator compounds through ozonation were found to be a function of the O 3 rate constants (k O3 ). For compounds with low O 3 rate constants (k O3 < 10 M -1 s -1 ), H 2 O 2 addition in the O 3 reactor was required. Of the 15 indicator compounds, tri(2-chloroethyl) phosphate (TCEP) and cotinine were observed to be the most recalcitrant. Although UV/H 2 O 2 with elevated intensity (700 mJ/cm 2 ) was effective for PPCP removals, energy requirements far exceed intensities applied for disinfection. Copyright © 2016 Elsevier Ltd. All rights reserved.
Straight-Pore Microfilter with Efficient Regeneration
NASA Technical Reports Server (NTRS)
Liu, Han; LaConti, Anthony B.; McCallum. Thomas J.; Schmitt, Edwin W.
2010-01-01
A novel, high-efficiency gas particulate filter has precise particle size screening, low pressure drop, and a simple and fast regeneration process. The regeneration process, which requires minimal material and energy consumption, can be completely automated, and the filtration performance can be restored within a very short period of time. This filter is of a novel material composite that contains the support structure and a novel coating.
Manzano-Fernández, Sergio; Andreu-Cayuelas, José M; Marín, Francisco; Orenes-Piñero, Esteban; Gallego, Pilar; Valdés, Mariano; Vicente, Vicente; Lip, Gregory Y H; Roldán, Vanessa
2015-06-01
New oral anticoagulants require dosing adjustment according to renal function. We aimed to determine discordance in hypothetical recommended dosing of these drugs using different estimated glomerular filtration rate equations in patients with atrial fibrillation. Cross-sectional analysis of 910 patients with atrial fibrillation and an indication for oral anticoagulation. The glomerular filtration rate was estimated using the Cockcroft-Gault, Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration equations. For dabigatran, rivaroxaban, and apixaban we identified dose discordance when there was disagreement in the recommended dose based on different equations. Among the overall population, relative to Cockcroft-Gault, discordance in dabigatran dosage was 11.4% for Modification of Diet in Renal Disease and 10% for Chronic Kidney Disease Epidemiology Collaboration, discordance in rivaroxaban dosage was 10% for Modification of Diet in Renal Disease and 8.5% for the Chronic Kidney Disease Epidemiology Collaboration. The lowest discordance was observed for apixaban: 1.4% for Modification of Diet in Renal Disease and 1.5% for the Chronic Kidney Disease Epidemiology Collaboration. In patients with Cockcroft-Gault<60mL/min or elderly patients, discordances in dabigatran and rivaroxaban dosages were higher, ranging from 13.2% to 30.4%. Discordance in apixaban dosage remained<5% in these patients. Discordance in new oral anticoagulation dosages using different equations is frequent, especially among elderly patients with renal impairment. This discordance was higher in dabigatran and rivaroxaban dosages than in apixaban dosages. Further studies are needed to clarify the clinical importance of these discordances and the optimal anticoagulant dosages depending on the use of different equations to estimate renal function. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Internal Structure and Morphology Profile in Optimizing Filter Membrane Performance
NASA Astrophysics Data System (ADS)
Sanaei, Pejman; Cummings, Linda J.
Membrane filters are in widespread use, and manufacturers have considerable interest in improving their performance, in terms of particle retention properties, and total throughput over the filter lifetime. A good question to ask is therefore: what is the optimal configuration of filter membranes, in terms of internal morphology (pore size and shape), to achieve the most efficient filtration? To answer this question, we must first propose a robust measure of filtration performance. As filtration occurs the membrane becomes blocked, or fouled, by the impurities in the feed solution, and any performance measure must take account of this. For example, one performance measure might be the total throughput (the volume of filtered feed solution) at the end of the filtration process, when the membrane is so badly blocked that it is deemed no longer functional. Here we present a simplified mathematical model, which (i) characterizes membrane internal pore structure via pore or permeability profiles in the depth of the membrane; (ii) accounts for various membrane fouling mechanisms (adsorption, blocking and cake formation); and (iv) predicts the optimum pore profile for our chosen performance measure. NSF DMS-1261596 and NSF DMS-1615719.
NASA Astrophysics Data System (ADS)
Astuti, A. D.; Lindu, M.; Yanidar, R.; Faruq, M.
2018-01-01
As environmental regulation has become stricter in recent years, there is an increasing concern about the issue of wastewater treatment in urban areas. Senior High School as center of student activity has a potential source to generated domestic wastewater from toilet, bathroom and canteen. Canteen wastewater contains high-organic content that to be treated before discharged. Based on previous research the subsurface constructed wetland-multilayer filtration with vertical flow is an attractive alternative to provide efficient treatment of canteen wastewater. The effluent concentration complied with regulation according to [9]. Due to limited land, addition of preliminary treatment such as the presence of biofilter was found to improve the performance. The aim of this study was to design combination biofilter and subsurface constructed wetland-multilayer filtration with vertical flow type using vetiveria zizanioides (akar wangi) treating canteen wastewater. Vetiveria zizanioides (akar wangi) is used because from previous research, subsurface constructed wetland-multilayer filtration (SCW-MLF) with vertical flow type using vetiveria zizanioides (akar wangi) can be an alternative canteen wastewater treatment that is uncomplicated in technology, low cost in operational and have a beautiful landscape view, besides no odors or insects were presented during the operation.
Xu, G R; Fitzpatrick, C S B; Deng, L Y
2006-01-01
Recent Cryptosporidium outbreaks have highlighted concerns about filter efficiency and especially particle breakthrough. Understanding the causes of breakthrough is essential, as the parasite cannot be destroyed by conventional disinfection with chlorine. Particle breakthrough depends on many factors. This research aims to investigate the influence of temperature, humic acid (HA) level and chemical dosing on particle breakthrough in filtration. A series of temperatures were set at 5 degrees C, 15 degrees C and 25 degrees C; humic acid level was 5 mg L(-1). Each was combined with a series of Al doses. A laser particle counter was used to assess the particle breakthrough online. Turbidity, zeta potential, and UV254 absorption were measured before and after filtration. The results showed that particle breakthrough was influenced significantly by temperature, humic acid and dosing. Particle breakthrough occurred earlier at lower temperature, while at higher temperature it was reduced at the same coagulant dose. With coagulants, even at low dose, particle breakthrough was significantly reduced. With HA 5 mg L(-1), particle breakthrough was earlier and the amount was much larger than without HA even at high temperature. There was an optimal dose in filtration and it was well correlated with zeta potential.
Jiang, T; Kennedy, M D; Guinzbourg, B F; Vanrolleghem, P A; Schippers, J C
2005-01-01
In order to optimize some operational conditions of MBR systems, a MBR pilot plant equipped with a submerged hollow fibre membrane module was employed in this study. The pilot MBR was fed with real municipal wastewater and the filtration flux, backwashing interval, aeration frequency and temperature were varied. A filtration flux below 25 I/m2h is generally recommended, at below this flux, the MBR operated at sub-critical flux conditions, the filter cake was minimized and membrane fouling was mainly attributed to the membrane pore blocking. Moreover, the membrane fouling, at below 25 I/m2h, was more reversible to backwashing; above this value, backwashing became less efficient to clean the membrane. Less frequent backwashing (e.g. 600 s filtration/45 s backwashing) decreased the amount of fouling irreversible to backwashing and its performance was superior to that of frequent backwashing (e.g. 200 s filtration/15 s backwashing). The MBR suffered more fouling at low temperature conditions (e.g. at 13-14 degrees C) than at high temperature conditions (e.g. at 17-18 degrees C). A conceptual model was built up and successfully interpreted this temperature effect.
Fate of leaf litter deposits and impacts on oxygen availability in bank filtration column studies.
Bayarsaikhan, Uranchimeg; Filter, Josefine; Gernert, Ulrich; Jekel, Martin; Ruhl, Aki Sebastian
2018-07-01
Degradation of particulate organic carbon (POC) such as leaf litter might deplete dissolved oxygen within the upper layers of bank filtration, an efficient and robust barrier for pathogens and for various organic micro-pollutants (OMP) in water supply systems worldwide. The degradation of OMP during bank filtration depends on the redox conditions. The present study aimed at identifying the impacts and fates of different local leaves on the oxygen consumption and the possible biological degradation of indicator OMP. Oxygen concentrations initially decreased within the columns from around 8 mg/L in the influent to low concentrations indicating extensive consumption within a short travel distance. Still a substantial oxygen consumption was observed after 250 days. OMP concentrations were not significantly affected by the microbial processes. A layer of calcium carbonate crystallites was observed on the POC layer. Some leaf fragments appeared to be persistant towards degradation and the carbon content relative to nitrogen and sulfur contents decreased within 250 days. The results demonstrate that trees at bank filtration sites might have a strong long-term impact on the subsurface redox conditions. Copyright © 2018 Elsevier Inc. All rights reserved.
Evaluation of gravimetric techniques to estimate the microvascular filtration coefficient
Dongaonkar, R. M.; Laine, G. A.; Stewart, R. H.
2011-01-01
Microvascular permeability to water is characterized by the microvascular filtration coefficient (Kf). Conventional gravimetric techniques to estimate Kf rely on data obtained from either transient or steady-state increases in organ weight in response to increases in microvascular pressure. Both techniques result in considerably different estimates and neither account for interstitial fluid storage and lymphatic return. We therefore developed a theoretical framework to evaluate Kf estimation techniques by 1) comparing conventional techniques to a novel technique that includes effects of interstitial fluid storage and lymphatic return, 2) evaluating the ability of conventional techniques to reproduce Kf from simulated gravimetric data generated by a realistic interstitial fluid balance model, 3) analyzing new data collected from rat intestine, and 4) analyzing previously reported data. These approaches revealed that the steady-state gravimetric technique yields estimates that are not directly related to Kf and are in some cases directly proportional to interstitial compliance. However, the transient gravimetric technique yields accurate estimates in some organs, because the typical experimental duration minimizes the effects of interstitial fluid storage and lymphatic return. Furthermore, our analytical framework reveals that the supposed requirement of tying off all draining lymphatic vessels for the transient technique is unnecessary. Finally, our numerical simulations indicate that our comprehensive technique accurately reproduces the value of Kf in all organs, is not confounded by interstitial storage and lymphatic return, and provides corroboration of the estimate from the transient technique. PMID:21346245
Altmann, Johannes; Rehfeld, Daniel; Träder, Kai; Sperlich, Alexander; Jekel, Martin
2016-04-01
Adsorption onto granular activated carbon (GAC) is an established technology in water and advanced wastewater treatment for the removal of organic substances from the liquid phase. Besides adsorption, the removal of particulate matter by filtration and biodegradation of organic substances in GAC contactors has frequently been reported. The application of GAC as both adsorbent for organic micropollutant (OMP) removal and filter medium for solids retention in tertiary wastewater filtration represents an energy- and space saving option, but has rarely been considered because high dissolved organic carbon (DOC) and suspended solids concentrations in the influent of the GAC adsorber put a significant burden on this integrated treatment step and might result in frequent backwashing and unsatisfactory filtration efficiency. This pilot-scale study investigates the combination of GAC adsorption and deep-bed filtration with coagulation as a single advanced treatment step for simultaneous removal of OMPs and phosphorus from secondary effluent. GAC was assessed as upper filter layer in dual-media downflow filtration and as mono-media upflow filter with regard to filtration performance and OMP removal. Both filtration concepts effectively removed suspended solids and phosphorus, achieving effluent concentrations of 0.1 mg/L TP and 1 mg/L TSS, respectively. Analysis of grain size distribution and head loss within the filter bed showed that considerable head loss occurred in the topmost filter layer in downflow filtration, indicating that most particles do not penetrate deeply into the filter bed. Upflow filtration exhibited substantially lower head loss and effective utilization of the whole filter bed. Well-adsorbing OMPs (e.g. benzotriazole, carbamazepine) were removed by >80% up to throughputs of 8000-10,000 bed volumes (BV), whereas weakly to medium adsorbing OMPs (e.g. primidone, sulfamethoxazole) showed removals <80% at <5,000 BV. In addition, breakthrough behavior was also determined for gabapentin, an anticonvulsant drug recently detected in drinking water resources for which suitable removal technologies are still largely unknown. Gabapentin showed poor adsorptive removal, resulting in rapid concentration increases. Whereas previous studies classified gabapentin as not readily biodegradable, sustained removal was observed after prolonged operation and points at biological elimination of gabapentin within the GAC filter. The application of GAC as filter medium was compared to direct addition of powdered activated carbon (PAC) to deep-bed filtration as a direct process alternative. Both options yielded comparable OMP removals for most compounds at similar carbon usage rates, but GAC achieved considerably higher removals for biodegradable OMPs. Based on the results, the application of GAC in combination with coagulation/filtration represents a promising alternative to powdered activated carbon and ozone for advanced wastewater treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cerny, R; Johnova, K; Otahal, P; Thinova, L; Kluson, J
2017-12-01
Radioactive aerosol particles represent a serious risk for people facing the consequences of nuclear accident of any kind. The first responders to emergency situation need to be protected by personal protective equipment which includes radiation protection suit supplemented with gas mask. The purpose of this work is to estimate the dose to the organs of responder's body as a result of radionuclide deposition in the filtration unit of the gas mask. The problem was analyzed using Monte Carlo simulations. The dose absorbed by different organs for five representative radionuclides and the dose distribution over the responder's body are presented in this paper. Based on presented MC simulations, we suggest a method of evaluating the irradiation of the responder by the radionuclides deposited in the filtration unit of the gas mask. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Measuring dynamic kidney function in an undergraduate physiology laboratory.
Medler, Scott; Harrington, Frederick
2013-12-01
Most undergraduate physiology laboratories are very limited in how they treat renal physiology. It is common to find teaching laboratories equipped with the capability for high-resolution digital recordings of physiological functions (muscle twitches, ECG, action potentials, respiratory responses, etc.), but most urinary laboratories still rely on a "dipstick" approach of urinalysis. Although this technique can provide some basic insights into the functioning of the kidneys, it overlooks the dynamic processes of filtration, reabsorption, and secretion. In the present article, we provide a straightforward approach of using renal clearance measurements to estimate glomerular filtration rate, fractional water reabsorption, glucose clearance, and other physiologically relevant parameters. The estimated values from our measurements in laboratory are in close agreement with those anticipated based on textbook parameters. For example, we found glomerular filtration rate to average 124 ± 45 ml/min, serum creatinine to be 1.23 ± 0.4 mg/dl, and fractional water reabsorption to be ∼96.8%. Furthermore, analyses for the class data revealed significant correlations between parameters like fractional water reabsorption and urine concentration, providing opportunities to discuss urine concentrating mechanisms and other physiological processes. The procedures outlined here are general enough that most undergraduate physiology laboratory courses should be able to implement them without difficulty.
Huq, A; Xu, B; Chowdhury, M A; Islam, M S; Montilla, R; Colwell, R R
1996-07-01
Plankton to which cells of Vibrio cholerae O1 and/or O139 were attached was introduced into 0.5% Instant Ocean microcosms maintained at 25 degrees C. The bulk of the plankton and associated particulates was removed with a filter constructed from either nylon net and one of several different types of sari material, the latter being very inexpensive and readily available in villages in Bangladesh, where V. cholerae is endemic. V. cholerae was enumerated before and after filtration to evaluate the efficiency of the filtration procedure. The results obtained indicate that 99% of V. cholerae, i.e., those cells attached to plankton, were removed from the water samples. Epidemic strains of V. cholerae O1 and O139 from various geographical sources, including Bangladesh, Brazil, India, and Mexico, were included in the experiments. Removal of vibrios from water by this simple filtration method was found to yield consistent results with all strains examined in this study. Thus, it is concluded that a simple filtration procedure involving the use of domestic sari material can reduce the number of cholera vibrios attached to plankton in raw water from ponds and rivers commonly used for drinking. Since untreated water from such sources serves as drinking water for millions of people living in developing countries (e.g., Bangladesh), filtration should prove effective at reducing the incidence and severity of outbreaks, especially in places that lack fuel wood for boiling water and/or municipal water treatment plants. The results of this study provide the basis for determining such reductions, which are to be carried out in the near future.
The Effects of Antifoam Agent on Dead End Filtration Process
NASA Astrophysics Data System (ADS)
Mohamad Pauzi, S.; Ahmad, N.; Yahya, M. F.; Arifin, M. A.
2018-05-01
The formation of foam as a result from introducing gases during cell culture process in the bioprocess industry has indirectly affected the throughput of the product of interest. Due to that, antifoams were developed and established as one of the means to minimize the formation of foam in the cell culture. There are many types of antifoams but the silicone-type of antifoams are widely used in the bioprocess industry. Although the establishment of antifoam has aided the cell culture process, the impacts of its presence in the cell culture to the downstream process especially the dead end filtration is not widely discussed. The findings in the study emphasized on the dead end filtration performance that includes flux rate profile and the resulted filtration capacity. In this study, the concentrations of antifoam injected into the solution were varied from 0.2% v/v – 1.0% v/v and the solutions were filtered using constant flow method. The resulted maximum pressure readings and final flux rates indicated that the resistance exerted to the feed flow rate increased as the concentration of antifoam loaded in the solution increased. This later has led to the decline in the flux rates with percentage reduction between 32 – 68%. The calculated filter capacity for flux rate of 1000LMH ranged from 53 – 63L/m2 while it is in the range of 40 – 43L/m2 for flux rate of 2000LMH. The presence of antifoam agents in the feed load was determined to have negative effects on the dead end filtration performance and it may reduce the efficiency of the dead end filtration process.
Ali, Gul Shad; El-Sayed, Ashraf S A; Patel, Jaimin S; Green, Kari B; Ali, Mohammad; Brennan, Mary; Norman, David
2016-01-15
Bacterial biological control agents (BCAs) are largely used as live products to control plant pathogens. However, due to variable environmental and ecological factors, live BCAs usually fail to produce desirable results against foliar pathogens. In this study, we investigated the potential of cell-free culture filtrates of 12 different bacterial BCAs isolated from flower beds for controlling foliar diseases caused by Alternaria spp. In vitro studies showed that culture filtrates from two isolates belonging to Bacillus subtilis and Bacillus amyloliquefaciens displayed strong efficacy and potencies against Alternaria spp. The antimicrobial activity of the culture filtrate of these two biological control agents was effective over a wider range of pH (3.0 to 9.0) and was not affected by autoclaving or proteolysis. Comparative liquid chromatography-mass spectrometry (LC-MS) analyses showed that a complex mixture of cyclic lipopeptides, primarily of the fengycin A and fengycin B families, was significantly higher in these two BCAs than inactive Bacillus spp. Interaction studies with mixtures of culture filtrates of these two species revealed additive activity, suggesting that they produce similar products, which was confirmed by LC-tandem MS analyses. In in planta pre- and postinoculation trials, foliar application of culture filtrates of B. subtilis reduced lesion sizes and lesion frequencies caused by Alternaria alternata by 68 to 81%. Taken together, our studies suggest that instead of live bacteria, culture filtrates of B. subtilis and B. amyloliquefaciens can be applied either individually or in combination for controlling foliar diseases caused by Alternaria species. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Rakruam, Pharkphum; Wattanachira, Suraphong
2014-03-01
This research was aimed at investigating the reduction of DOM fractions and their trihalomethane formation potential (THMFP) by in-line coagulation with 0.1 μm ceramic membrane filtration. The combination of ceramic membrane filtration with a coagulation process is an alternative technology which can be applied to enhance conventional coagulation processes in the field of water treatment and drinking water production. The Ping River water (high turbidity water) was selected as the raw surface water because it is currently the main raw water source for water supply production in the urban and rural areas of Chiang Mai Province. From the investigation, the results showed that the highest percent reductions of DOC, UV-254, and THMFP (47.6%, 71.0%, and 67.4%, respectively) were achieved from in-line coagulation with ceramic membrane filtration at polyaluminum chloride dosage 40 mg/L. Resin adsorption techniques were employed to characterize the DOM in raw surface water and filtered water. The results showed that the use of a ceramic membrane with in-line coagulation was able to most efficiently reduce the hydrophobic fraction (HPOA) (68.5%), which was then followed by the hydrophilic fraction (HPIA) (49.3%). The greater mass DOC reduction of these two fractions provided the highest THMFP reductions (55.1% and 37.2%, respectively). Furthermore, the in-line coagulation with ceramic membrane filtration was able to reduce the hydrophobic (HPOB) fraction which is characterized by high reactivity toward THM formation. The percent reduction of mass DOC and THMFP of HPOB by in-line coagulation with ceramic membrane filtration was 45.9% and 48.0%, respectively. Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
Hu, Jing; Liu, Zuoliang; Zhang, Hao
2017-01-01
The aim of this study was to evaluate the benefits and risks of omega-3 fatty acid supplementation in patients with chronic kidney disease. A systematic search of articles in PubMed, Embase, the Cochrane Library, and reference lists was performed to find relevant literature. All eligible studies assessed proteinuria, the serum creatinine clearance rate, the estimated glomerular filtration rate, or the occurrence of end-stage renal disease. Standard mean differences with 95% confidence intervals for continuous data were used to estimate the effects of omega-3 fatty acid supplementation on renal function, as reflected by the serum creatinine clearance rate, proteinuria, the estimated glomerular filtration rate, and relative risk. Additionally, a random-effects model was used to estimate the effect of omega-3 fatty acid supplementation on the risk of end-stage renal disease. Nine randomized controlled trials evaluating 444 patients with chronic kidney disease were included in the study. The follow-up duration ranged from 2 to 76.8 months. Compared with no or low-dose omega-3 fatty acid supplementation, any or high-dose omega-3 fatty acid supplementation, respectively, was associated with a lower risk of proteinuria (SMD: -0.31; 95% CI: -0.53 to -0.10; p=0.004) but had little or no effect on the serum creatinine clearance rate (SMD: 0.22; 95% CI: -0.40 to 0.84; p=0.482) or the estimated glomerular filtration rate (SMD: 0.14; 95% CI: -0.13 to 0.42; p=0.296). However, this supplementation was associated with a reduced risk of end-stage renal disease (RR: 0.49; 95% CI: 0.24 to 0.99; p=0.047). In sum, omega-3 fatty acid supplementation is associated with a significantly reduced risk of end-stage renal disease and delays the progression of this disease.
Comparison of filtration mechanisms of food and industrial grade TiO2 nanoparticles.
Chen, Chen; Marcus, Ian M; Waller, Travis; Walker, Sharon L
2018-05-21
The removal of food and industrial grade titanium dioxide (TiO 2 ) particles through drinking water filtration was assessed via direct visualization of an in situ 2-D micromodel. The goal of this research was to determine whether variances in surface composition, aggregate size, and ionic strength result in different transport and deposition processes in porous media. Food and industrial grade TiO 2 particles were characterized by measuring their hydrodynamic diameter, zeta potential, and zero point of charge before introduction into the 2-D micromodel. The removal efficiency as a function of position on the collector surface was calculated from direct visualization measurements. Notably, food grade TiO 2 had a lower removal efficiency when compared with industrial grade. The difference in removal efficiency between the two particle types could be attributed to the higher stability (as indicated by the larger zeta potential values) of the food grade particles, which lead to a reduced aggregate size when compared to the industrial grade particles. This removal efficiency trend was most pronounced in the rear stagnation point, due to the high contribution of hydrodynamic forces at that point. It could be inferred from the results presented herein that particle removal strategies should be based on particle aggregate size and surface charge. Graphical abstract ᅟ.
[Decline in renal function in old age : Part of physiological aging versus age-related disease].
Braun, F; Brinkkötter, P T
2016-08-01
The incidence and prevalence of chronic renal disease (CKD) in elderly patients are continuously increasing worldwide. Loss of renal function is not only considered to be part of the aging process itself but also reflects the multimorbidity of many geriatric patients. Calculating the glomerular filtration rate using specific algorithms validated for the elderly population and measuring the amount of proteinuria allow an estimation of renal function in elderly patients with high accuracy. Chronic renal failure has many clinical consequences and not only results in a delayed excretion of toxins cleared by the kidneys but also affects hematogenesis, water and electrolyte balance as well as mineral bone metabolism. Furthermore, CKD directly leads to and aggravates geriatric syndromes and in particular the onset of frailty. Therapeutic strategies to halt progression of CKD not only comprise treatment of the underlying disease but also efficient blood pressure and diabetic control and the avoidance of nephrotoxic medications.
Selective removal of cesium by ammonium molybdophosphate - polyacrylonitrile bead and membrane.
Ding, Dahu; Zhang, Zhenya; Chen, Rongzhi; Cai, Tianming
2017-02-15
The selective removal of radionuclides with extremely low concentrations from environmental medium remains a big challenge. Ammonium molybdophosphate possess considerable selectivity towards cesium ion (Cs + ) due to the specific ion exchange between Cs + and NH 4 + . Ammonium molybdophosphate - polyacrylonitrile (AMP-PAN) membrane was successfully prepared for the first time in this study. Efficient removal of Cs + (95.7%, 94.1% and 91.3% of 1mgL -1 ) from solutions with high ionic strength (400mgL -1 of Na + , Ca 2+ or K + ) was achieved by AMP-PAN composite. Multilayer chemical adsorption process was testified through kinetic and isotherm studies. The estimated maximum adsorption capacities even reached 138.9±21.3mgg -1 . Specifically, the liquid film diffusion was identified as the rate-limiting step throughout the removal process. Finally, AMP-PAN membrane could eliminate Cs + from water effectively through the filtration adsorption process. Copyright © 2016 Elsevier B.V. All rights reserved.
Removal of humic acid by a new type of electrical hollow-fiber microfiltration (E-HFMF)
NASA Astrophysics Data System (ADS)
Shang, Ran; Deng, Hui-ping; Hu, Jing-yi
2010-11-01
Low pressure membrane filtration, such as microfiltration, was widely used in the field of drinking water purification in the past few decades. Traditional microfiltration membranes are not efficient enough in the removal of natural organic matters (NOM) from raw water. Moreover, they tend to be fouled by the NOM and the filtration age of the membranes is thus shrinked. To tackle these problems, a new type of electrical hollow-fiber microfiltration module (E-HFMF) was designed. In the E-HFMF module, the hollow-fiber microfiltration membranes were placed into the radialized electrical field which functioned from the centre to the exterior of the cylindrical cavity. The main goal of the present study was to evaluate the efficiency of E-HFMF to remove the humic acid (HA, one of the main components of NOM). According to the parallel tests compared with the traditional microfiltration, the removal rate of humic acid was raised to 70%˜85% in terms of UV-254 and to 60%˜75% in terms of DOC when filtrating with the E-HFMF, while the removal rates of humic acid were 10%˜20% and 1%˜10% respectively when filtrating with the traditional microfiltration. The negative charged humic acid moved to the anode because of the electrophoresis, so few humic acid could be able to permeate through the membrane. The electrophoresis mobility of the humic acid permeating through the traditional microfiltration decreased by 19%, while the same index from the E-HFMF decreased by 75%. This indicated that the electrophoresis played a significant role on removing the humic acid. According to the gel permeate chromatograph analysis, humic acid aggregated in an electric field and thus forms loose and permeable cake layer on the membrane surface, which also relieved membrane fouling. Meanwhile, the negative charged humic acid migrating to the anode at the center minimized the deposition onto the membrane surface, and eliminated the membrane fouling as a result. During the E-HFMF filtration, the humic acid was not oxidized observably in the electrical field, according to the FT-IR analysis.
Singh, Varun Kumar; Ravi, Sai Kishore; Sun, Wanxin; Tan, Swee Ching
2017-02-01
Alarming levels of particulate matter pollution in air pose a serious health threat in several countries, therefore intriguing a strong need for an economic and a viable technology of air filtration. Current air purification technology is rather expensive with certain types even having the risk of emitting hazardous by-products. The authors have developed a multifunctional air filter inspired from the nasal hairs possessing an ability to specifically trap/exhale the foreign particles and allergens while still letting the air flow. This design is achieved by introducing different functionalities at different dimensional scale employing a bottom-up approach starting with an organic molecule which is further self-organized to form nanoparticles and ultimately to a nanofibrous mesh. While the molecular building block inherently possesses the property of shielding Ultraviolet (UV) rays, the nanofibrous mesh built up from it aids in trapping the particulate matter while maintaining good air flow. By controlling the concentration of the organic molecule, the formation of fibers has been enabled in the nanoscale regime to obtain high particle-capture possibilities. The self-assembled nanofibrous filter thus designed has achieved a high filtration efficiency of ≈90% for the PM 2.5 particle in congruence with the ability to block the harmful UV radiations. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Iwama, Ryosuke; Sato, Tsubasa; Katayama, Masaaki; Shimamura, Shunsuke; Satoh, Hiroshi; Ichijo, Toshihiro; Furuhama, Kazuhisa
2015-08-01
We examined the correlation between the glomerular filtration rate (GFR) estimated from an equation based on the serum iodixanol clearance technique and International Renal Interest Society (IRIS) stages of chronic kidney disease (CKD) in cats. The equation included the injection dose, sampling time, serum concentration and estimated volume of distribution (Vd) of the isotonic, nonionic, contrast medium iodixanol as a test tracer. The percent changes in the median basal GFR values calculated from the equation in CKD cats resembled those of IRIS stages 1-3. These data validate the association between the GFR derived from the simplified equation and IRIS stages based on the serum creatinine concentration in cats with CKD. They describe the GFR ranges determined using single-sample iodixanol clearance for healthy cats and cats with various IRIS stages of CKD.
[Bioimpedometry and its utilization in dialysis therapy].
Lopot, František
2016-01-01
Measurement of living tissue impedance - bioimpedometry - started to be used in medicine some 50 years ago, first exclusively for estimation of extracellular and intracellular compartment volumes. Its most simple single frequency (50 kHz) version works directly with the measured impedance vector. Technically more sophisticated versions convert the measured impedance in values of volumes of different compartments of body fluids and calculate also principal markers of nutritional status (lean body mass, adipose tissue mass). The latest version specifically developed for application in dialysis patients includes body composition modelling and provides even absolute value of overhydration (excess fluid). Still in experimental phase is the bioimpedance exploitation for more precise estimation of residual glomerular filtration. Not yet standardized is also segmental bioimpedance measurement which should enable separate assessment of hydration status of the trunk segment and ultrafiltration capacity of peritoneum in peritoneal dialysis patients.Key words: assessment - bioimpedance - excess fluid - fluid status - glomerular filtration - haemodialysis - nutritional status - peritoneal dialysis.
Maeng, Sung Kyu; Ameda, Emmanuel; Sharma, Saroj K; Grützmacher, Gesche; Amy, Gary L
2010-07-01
Natural treatment systems such as bank filtration (BF) and artificial recharge (via an infiltration basin) are a robust barrier for many organic micropollutants (OMPs) and may represent a low-cost alternative compared to advanced drinking water treatment systems. This study analyzes a comprehensive database of OMPs at BF and artificial recharge (AR) sites located near Lake Tegel in Berlin (Germany). The focus of the study was on the derivation of correlations between the removal efficiencies of OMPs and key factors influencing the performance of BF and AR. At the BF site, shallow monitoring wells located close to the Lake Tegel source exhibited oxic conditions followed by prolonged anoxic conditions in deep monitoring wells and a production well. At the AR site, oxic conditions prevailed from the recharge pond along monitoring wells to the production well. Long residence times of up to 4.5 months at the BF site reduced the temperature variation during soil passage between summer and winter. The temperature variations were greater at the AR site as a consequence of shorter residence times. Deep monitoring wells and the production well located at the BF site were under the influence of ambient groundwater and old bank filtrate (up to several years of age). Thus, it is important to account for mixing with native groundwater and other sources (e.g., old bank filtrate) when estimating the performance of BF with respect to removal of OMPs. Principal component analysis (PCA) was used to investigate correlations between OMP removals and hydrogeochemical conditions with spatial and temporal parameters (e.g., well distance, residence time and depth) from both sites. Principal component-1 (PC1) embodied redox conditions (oxidation-reduction potential and dissolved oxygen), and principal component-2 (PC2) embodied degradation potential (e.g., total organic carbon and dissolved organic carbon) with the calcium carbonate dissolution potential (Ca(2+) and HCO(3)(-)) for the BF site. These two PCs explained a total variance of 55% at the BF site. At the AR site, PCA revealed redox conditions (PC1) and degradation potential with temperature (PC2) as principal components, which explained a total variance of 56%. Copyright 2010 Elsevier Ltd. All rights reserved.
Development of an Indexing Media Filtration System for Long Duration Space Missions
NASA Technical Reports Server (NTRS)
Agui, Juan H.; Vijayakumar, R.
2013-01-01
The effective maintenance of air quality aboard spacecraft cabins will be vital to future human exploration missions. A key component will be the air cleaning filtration system which will need to remove a broad size range of particles derived from multiple biological and material sources. In addition, during surface missions any extraterrestrial planetary dust, including dust generated by near-by ISRU equipment, which is tracked into the habitat will also need to be managed by the filtration system inside the pressurized habitat compartments. An indexing media filter system is being developed to meet the demand for long-duration missions that will result in dramatic increases in filter service life and loading capacity, and will require minimal crew involvement. The filtration system consists of three stages: an inertial impactor stage, an indexing media stage, and a high-efficiency filter stage, packaged in a stacked modular cartridge configuration. Each stage will target a specific range of particle sizes that optimize the filtration and regeneration performance of the system. An 1/8th scale and full-scale prototype of the filter system have been fabricated and have been tested in the laboratory and reduced gravity environments that simulate conditions on spacecrafts, landers and habitats. Results from recent laboratory and reduce-gravity flight tests data will be presented. The features of the new filter system may also benefit other closed systems, such as submarines, and remote location terrestrial installations where servicing and replacement of filter units is not practical.
Development of an Indexing Media Filtration System for Long Duration Space Missions
NASA Technical Reports Server (NTRS)
Agui, Juan H.; Vijayakumar, R.
2013-01-01
The effective maintenance of air quality aboard spacecraft cabins will be vital to future human exploration missions. A key component will be the air cleaning filtration system which will need to remove a broad size range of particles including skin flakes, hair and clothing fibers, other biological matter, and particulate matter derived from material and equipment wear. In addition, during surface missions any extraterrestrial planetary dust, including dust generated by near-by ISRU equipment, which is tracked into the habitat will also need to be managed by the filtration system inside the pressurized habitat compartments. An indexing media filter system is being developed to meet the demand for long-duration missions that will result in dramatic increases in filter service life and loading capacity, and will require minimal crew involvement. These features may also benefit other closed systems, such as submarines, and remote location terrestrial installations where servicing and replacement of filter units is not practical. The filtration system consists of three stages: an inertial impactor stage, an indexing media stage, and a high-efficiency filter stage, packaged in a stacked modular cartridge configuration. Each stage will target a specific range of particle sizes that optimize the filtration and regeneration performance of the system. An 1/8th scale and full-scale prototype of the filter system have been fabricated and have been tested in the laboratory and reduced gravity environments that simulate conditions on spacecrafts, landers and habitats. Results from recent laboratory and reducegravity flight tests data will be presented.
ERIC Educational Resources Information Center
Frank, David J.
1998-01-01
Discusses the creation of an effective carpet vacuuming program by combining area usage assessment and vacuuming requirements with a scheduling plan. Also explains vacuum cleaner suction and filtration and how it makes custodian work more efficient. A complementary article discusses creating an effective floor-maintenance plan for resilient…
ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: PAINT OVERSPRAY ARRESTOR, FARR COMPANY RIGA-FLO 200
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: PAINT OVERSPRAY ARRESTOR, ATI OSM 200 SYSTEM
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: PAINT OVERSPRAY ARRESTOR, COLUMBUS INDUSTRIES SL-46B
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
Caught in a net: Retention efficiency of microplankton ≥ 10 and < 50 μm collected on mesh netting
NASA Astrophysics Data System (ADS)
Molina, Vanessa; Robbins-Wamsley, Stephanie H.; Riley, Scott C.; First, Matthew R.; Drake, Lisa A.
2018-03-01
Living organisms ≥ 10 μm and < 50 μm in ballast water discharged from ships are typically collected by filtering samples through a monofilament mesh net with pore openings sized to retain organisms ≥ 10 μm. This (or any) filtering method does not result in perfect size fractionation, and it can induce stress, mortality, and loss of organisms that, in turn, may underestimate the concentration of organisms within samples. To address this loss, the retention efficiency (RE) was determined for six filtration approaches using laboratory cultures of microalgae and ambient marine organisms. The approaches employed a membrane filter or mesh nettings of different compositions (nylon, stainless steel, polyester, and polycarbonate), nominal pore sizes (5, 7, and 10 μm), and filtering sequences (e.g., pre-filtering water through a coarse filter). Additionally, in trials with polycarbonate track etched (PCTE) membrane filters, water was amended with particulate material to increase turbidity. Organisms ≥ 10 μm were counted in the material retained on the filter (the filtrand), the material passing through the filter (the filtrate), and the whole water (i.e., unfiltered water). In addition, variable fluorescence fluorometry was used to gauge the relative photochemical yield of phytoplankton-a proximal measurement of the physiological status of phytoplankton-in the size fractions. Further, the mesh types and filters were examined using scanning electron microscopy, which showed irregular openings. The RE of cultured organisms-calculated as the concentration in the filtrand relative to combined concentration in the filtrand and the filtrate-was high for all filtration approaches when laboratory cultures were assessed (> 93%), but RE ranged from 66 to 98% when mixed assemblages of ambient organisms were evaluated. Although PCTE membrane filters had the highest RE (98%), it was not significantly higher than the efficiencies of the 7-μm polyester, Double 7-μm polyester, and Dual 35-μm and 7-μm polyester approaches, but it was significantly higher than the 5-μm nylon and 5-μm stainless steel techniques. This result suggests that PCTE membrane filters perform comparably to 7-μm polyester meshes, so that any of these approaches could be used for concentrating organisms. However, the potential for handling loss is inherently lower for one rinsing step rather than two. Therefore, it is recommended that, either PCTE filters or 7-μm polyester mesh could be used to concentrate organisms ≥ 10 μm and < 50 μm. In trials conducted using a 10-μm PCTE filters with water amended to increase the particulate concentration, no significant difference in RE of ambient organisms was found compared to unamended water. Finally, photochemical yield did not vary significantly between organisms in the filtrand or filtrate, regardless of the filtration approach used.
2009-01-01
An important part of characterizing any protein molecule is to determine its size and shape. Sedimentation and gel filtration are hydrodynamic techniques that can be used for this medium resolution structural analysis. This review collects a number of simple calculations that are useful for thinking about protein structure at the nanometer level. Readers are reminded that the Perrin equation is generally not a valid approach to determine the shape of proteins. Instead, a simple guideline is presented, based on the measured sedimentation coefficient and a calculated maximum S, to estimate if a protein is globular or elongated. It is recalled that a gel filtration column fractionates proteins on the basis of their Stokes radius, not molecular weight. The molecular weight can be determined by combining gradient sedimentation and gel filtration, techniques available in most biochemistry laboratories, as originally proposed by Siegel and Monte. Finally, rotary shadowing and negative stain electron microscopy are powerful techniques for resolving the size and shape of single protein molecules and complexes at the nanometer level. A combination of hydrodynamics and electron microscopy is especially powerful. PMID:19495910
NASA Technical Reports Server (NTRS)
Laicer, Castro; Rasimick, Brian; Green, Zachary
2012-01-01
Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of dust particles on the filter surface and to facilitate dust removal with pulse or back airflow.
Lam, K S; Chan, F S; Fung, W Y; Lui, B S S; Lau, L W L
2006-04-01
A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficiency particulates air (HEPA) filters were tested in a commercial building in Causeway Bay. The results show that an RSP objective of <20 microg/m3 could be met by removing RSP from both the return air and outdoor air supply simultaneously. This level of performance is classed as 'excellent' by the Hong Kong Government, Environmental Protection Department. Filters with efficiency that exceed 80% placed both in the return air and outdoor air were sufficient to meet the objective. It is not necessary to install HEPA filters to achieve the 'excellent' class. The outdoor air filter has great influence on the steady state indoor RSP concentration while the effective cleaning rate is governed by the return air filter. Higher efficiency filters increased the static drop but the volume flow of the air fan was not affected significantly. The additional cost incurred was <5% of the existing operation cost. This paper reports a field study of RSP control for an indoor office environment. The results are directly applicable to building service engineering in the design of ventilation systems using air-handling units. Field observations indicated that indoor RSP in an office environment could be suppressed below 20 microg/m3 within 1 h by the simultaneous filtration of outdoor air and return air. Outdoor air filtration has a great influence on the steady state indoor concentration and return air filtration governs the cleaning rate. It is believed that the results of this study could be extended to the cleaning of other indoor pollutants such as volatile organic compounds.
Rovin, B H; Dooley, M A; Radhakrishnan, J; Ginzler, E M; Forrester, T D; Anderson, P W
2016-12-01
Tabalumab is a monoclonal antibody that neutralizes membrane and soluble B-cell activating factor. Two 52-week, randomized, double-blind, placebo controlled phase 3 trials evaluated the safety and efficacy of tabalumab in systemic lupus erythematosus. Patients with moderate to severe active systemic lupus erythematosus (without severe active lupus nephritis) were randomly assigned 1:1:1 to receive tabalumab (120 mg subcutaneously every 2 or 4 weeks) or placebo for 52 weeks. Serum creatinine concentration, estimated glomerular filtration rate, urine protein/creatinine ratio, renal flares and renal adverse events were determined monthly. Data were analyzed for the intent-to-treat population and for intent-to-treat patients with baseline urine protein/creatinine ratio >20 mg/mmol (intent-to-treat plus urine protein/creatinine ratio). The trials enrolled 2262 patients. At baseline, demographics, systemic lupus erythematosus disease activity, serum creatinine concentration, estimated glomerular filtration rate and urine protein/creatinine ratio were similar among the treatment arms (with the exception of disease duration). In the intent-to-treat and intent-to-treat plus urine protein/creatinine ratio populations, there were no differences between the arms in the baseline-to-endpoint change in serum creatinine concentration, glomerular filtration rate, urine protein/creatinine ratio, or renal flare rates. Tabalumab resulted in a significant B-cell reduction and decreased immunoglobulin G levels at both doses. Compared to placebo, tabalumab did not significantly affect the serum creatinine concentration, glomerular filtration rate, urine protein/creatinine ratio, or renal flare rates over 1 year in intent-to-treat or intent-to-treat plus urine protein/creatinine ratio patients. There were no significant renal safety signals.ClinicalTrials.gov identifiers: NCT01205438 and NCT01196091 Lupus (2016) 25, 1597-1601. © The Author(s) 2016.
Prevalence of and risk factors for reduced serum bicarbonate in chronic kidney disease.
Raphael, Kalani L; Zhang, Yingying; Ying, Jian; Greene, Tom
2014-10-01
The prevalence of metabolic acidosis increases as glomerular filtration rate falls. However, most patients with stage 4 chronic kidney disease have normal serum bicarbonate concentration while some with stage 3 chronic kidney disease have low serum bicarbonate, suggesting that other factors contribute to generation of acidosis. The purpose of this study is to identify risk factors, other than reduced glomerular filtration rate, for reduced serum bicarbonate in chronic kidney disease. This is a cross-sectional analysis of baseline data from the Chronic Renal Insufficiency Cohort Study. Multivariable logistic and linear regression models were used to relate predictor variables to the odds of low serum bicarbonate (< 22 mM) compared with normal serum bicarbonate (22-30 mM) and the coefficients of Δ serum bicarbonate concentration. The prevalence of low serum bicarbonate at baseline was 17.3%. Lower estimated glomerular filtration rate had the strongest relationship with low serum bicarbonate. Factors associated with higher odds of low serum bicarbonate, independent of estimated glomerular filtration rate, were urinary albumin/creatinine ≥ 10 mg/g, smoking, anaemia, hyperkalaemia, non-diuretic use and higher serum albumin. These and younger age, higher waist circumference, and use of angiotensin converting enzyme inhibitors or angiotensin receptor blockers associated with negative Δ serum bicarbonate in linear regression models. Several factors not typically considered to associate with reduced serum bicarbonate in chronic kidney disease were identified including albuminuria ≥ 10 mg/g, anaemia, smoking, higher serum albumin, higher waist circumference, and use of angiotensin converting enzyme inhibitors or angiotensin receptor blockers. Future studies should explore the longitudinal effect of these factors on serum bicarbonate concentration. © 2014 Asian Pacific Society of Nephrology.
Breakthrough of cyanobacteria in bank filtration.
Pazouki, Pirooz; Prévost, Michèle; McQuaid, Natasha; Barbeau, Benoit; de Boutray, Marie-Laure; Zamyadi, Arash; Dorner, Sarah
2016-10-01
The removal of cyanobacteria cells in well water following bank filtration was investigated from a source water consisting of two artificial lakes (A and B). Phycocyanin probes used to monitor cyanobacteria in the source and in filtered well water showed an increase of fluorescence values demonstrating a progressive seasonal growth of cyanobacteria in the source water that were correlated with cyanobacterial biovolumes from taxonomic counts (r = 0.59, p < 0.00001). A strong correlation was observed between the cyanobacterial concentrations in the lake water and in the well water as measured by the phycocyanin probe (p < 0.001, 0.73 ≤ r(2) ≤ 0.94). Log removals from bank filtration estimated from taxonomic counts ranged from 0.96 ± (0.5) and varied according to the species of cyanobacteria. Of cyanobacteria that passed through bank filtration, smaller cells were significantly more frequent in well water samples (p < 0.05) than larger cells. Travel times from the lakes to the wells were estimated as 2 days for Lake B and 10 days for Lake A. Cyanobacterial species in the wells were most closely related to species found in Lake B. Thus, a travel time of less than 1 week permitted the breakthrough of cyanobacteria to wells. Winter samples demonstrated that cyanobacteria accumulate within bank filters, leading to continued passage of cells beyond the bloom season. Although no concentrations of total microcystin-LR were above detection limits in filtered well water, there is concern that cyanobacterial cells that reach the wells have the potential to contain intracellular toxins. Copyright © 2016 Elsevier Ltd. All rights reserved.
Removal of emerging micropollutants from water using cyclodextrin.
Nagy, Zsuzsanna Magdolna; Molnár, Mónika; Fekete-Kertész, Ildikó; Molnár-Perl, Ibolya; Fenyvesi, Éva; Gruiz, Katalin
2014-07-01
Small scale laboratory experiment series were performed to study the suitability of a cyclodextrin-based sorbent (ß-cyclodextrin bead polymer, BCDP) for modelling the removal of micropollutants from drinking water and purified waste water using simulated inflow test solutions containing target analytes (ibuprofen, naproxen, ketoprofen, bisphenol-A, diclofenac, β-estradiol, ethinylestradiol, estriol, cholesterol at 2-6 μg/L level). This work was focused on the preliminary evaluation of BCDP as a sorbent in two different model systems (filtration and fluidization) applied for risk reduction of emerging micropollutants. For comparison different filter systems combined with various sorbents (commercial filter and activated carbon) were applied and evaluated in the filtration experiment series. The spiked test solution (inflow) and the treated outflows were characterized by an integrated methodology including chemical analytical methods gas chromatography-tandem mass spectrometry (GC-MS/MS) and various environmental toxicity tests to determine the efficiency and selectivity of the applied sorbents. Under experimental conditions the cyclodextrin-based filters used for purification of drinking water in most cases were able to absorb more than 90% of the bisphenol-A and of the estrogenic compounds. Both the analytical chemistry and toxicity results showed efficient elimination of these pollutants. Especially the toxicity of the filtrate decreased considerably. Laboratory experiment modelling post-purification of waste water was also performed applying fluidization technology by ß-cyclodextrin bead polymer. The BCDP removed efficiently from the spiked test solution most of the micropollutants, especially the bisphenol-A (94%) and the hormones (87-99%) The results confirmed that the BCDP-containing sorbents provide a good solution to water quality problems and they are able to decrease the load and risk posed by micropollutants to the water systems. Copyright © 2014 Elsevier B.V. All rights reserved.
Challenge of N95 Filtering Facepiece Respirators with Viable H1N1 Influenza Aerosols
Harnish, Delbert A.; Heimbuch, Brian K.; Husband, Michael; Lumley, April E.; Kinney, Kimberly; Shaffer, Ronald E.; Wander, Joseph D.
2015-01-01
OBJECTIVE Specification of appropriate personal protective equipment for respiratory protection against influenza is somewhat controversial. In a clinical environment, N95 filtering facepiece respirators (FFRs) are often recommended for respiratory protection against infectious aerosols. This study evaluates the ability of N95 FFRs to capture viable H1N1 influenza aerosols. METHODS Five N95 FFR models were challenged with aerosolized viable H1N1 influenza and inert polystyrene latex particles at continuous flow rates of 85 and 170 liters per minute. Virus was assayed using Madin-Darby canine kidney cells to determine the median tissue culture infective dose (TCID50). Aerosols were generated using a Collison nebulizer containing H1N1 influenza virus at 1 × 108 TCID50/mL. To determine filtration efficiency, viable sampling was performed upstream and downstream of the FFR. RESULTS N95 FFRs filtered 0.8-µm particles of both H1N1 influenza and inert origins with more than 95% efficiency. With the exception of 1 model, no statistically significant difference in filtration performance was observed between influenza and inert particles of similar size. Although statistically significant differences were observed for 2 models when comparing the 2 flow rates, the differences have no significance to protection. CONCLUSIONS This study empirically demonstrates that a National Institute for Occupational Safety and Health–approved N95 FFR captures viable H1N1 influenza aerosols as well as or better than its N95 rating, suggesting that a properly fitted FFR reduces inhalation exposure to airborne influenza virus. This study also provides evidence that filtration efficiency is based primarily on particle size rather than the nature of the particle’s origin. PMID:23571366
Zanacic, Enisa; Stavrinides, John; McMartin, Dena W
2016-11-01
Potable water treatment in small communities is challenging due to a complexity of factors starting with generally poor raw water sources, a smaller tax and consumption base that limit capital and operating funds, and culminating in what is typically a less sophisticated and robust water treatment plant for production and delivery of safe, high quality potable water. The design and optimization of modular ozone-assisted biological filtration systems can address some of these challenges. In surface water treatment, the removal of organic matter (e.g., dissolved organic carbon - DOC), inorganic nutrients and other exposure-related contaminants (e.g., turbidity and dissolved solids) from the raw water source is essential. Thus, a combination of chemical and biological oxidation processes can produce an effective and efficient water treatment plant design that is also affordable and robust. To that end, the ozone-assisted biological filtration water treatment plants in two communities were evaluated to determine the efficacy of oxidation and contaminant removal processes. The results of testing for in-field system performance indicate that plant performance is particularly negatively impacted by high alkalinity, high organics loading, and turbidity. Both bicarbonate and carbonate alkalinity were observed to impede ozone contact and interaction with DOC, resulting in lower than anticipated DOC oxidation efficiency and bioavailability. The ozone dosage at both water treatment plants must be calculated on a more routine basis to better reflect both the raw water DOC concentration and presence of alkalinities to ensure maximized organics oxidation and minimization of trihalomethanes production. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Universal and reusable virus deactivation system for respiratory protection
NASA Astrophysics Data System (ADS)
Quan, Fu-Shi; Rubino, Ilaria; Lee, Su-Hwa; Koch, Brendan; Choi, Hyo-Jick
2017-01-01
Aerosolized pathogens are a leading cause of respiratory infection and transmission. Currently used protective measures pose potential risk of primary/secondary infection and transmission. Here, we report the development of a universal, reusable virus deactivation system by functionalization of the main fibrous filtration unit of surgical mask with sodium chloride salt. The salt coating on the fiber surface dissolves upon exposure to virus aerosols and recrystallizes during drying, destroying the pathogens. When tested with tightly sealed sides, salt-coated filters showed remarkably higher filtration efficiency than conventional mask filtration layer, and 100% survival rate was observed in mice infected with virus penetrated through salt-coated filters. Viruses captured on salt-coated filters exhibited rapid infectivity loss compared to gradual decrease on bare filters. Salt-coated filters proved highly effective in deactivating influenza viruses regardless of subtypes and following storage in harsh environmental conditions. Our results can be applied in obtaining a broad-spectrum, airborne pathogen prevention device in preparation for epidemic and pandemic of respiratory diseases.
Use of mep HyperCel for polishing of human serum albumin.
McCann, Karl B; Vucica, Yvonne; Wu, John; Bertolini, Joseph
2014-10-15
The manufacture of human serum albumin by chromatographic procedures involves gel filtration chromatography as a final polishing step. Despite this step being essential to remove high molecular weight impurity proteins and thus ensure a stable and safe final product, it is relatively inefficient. This paper explores the use of hydrophobic charge induction chromatographic media, MEP HyperCel as an alternative to Sephacryl S200HR gel filtration for the polishing of human serum albumin derived by ion exchange chromatographic purification of Cohn Supernatant I. The use of MEP HyperCel results in a product with a higher purity than achieved with gel filtration and in a less time consuming manner and with potential resource savings. MEP HyperCel appears to have great potential for incorporation into downstream processes in the plasma fractionation industry as an efficient means of achieving polishing of intermediates or capture of proteins of interest. Copyright © 2014 Elsevier B.V. All rights reserved.
Universal and reusable virus deactivation system for respiratory protection
Quan, Fu-Shi; Rubino, Ilaria; Lee, Su-Hwa; Koch, Brendan; Choi, Hyo-Jick
2017-01-01
Aerosolized pathogens are a leading cause of respiratory infection and transmission. Currently used protective measures pose potential risk of primary/secondary infection and transmission. Here, we report the development of a universal, reusable virus deactivation system by functionalization of the main fibrous filtration unit of surgical mask with sodium chloride salt. The salt coating on the fiber surface dissolves upon exposure to virus aerosols and recrystallizes during drying, destroying the pathogens. When tested with tightly sealed sides, salt-coated filters showed remarkably higher filtration efficiency than conventional mask filtration layer, and 100% survival rate was observed in mice infected with virus penetrated through salt-coated filters. Viruses captured on salt-coated filters exhibited rapid infectivity loss compared to gradual decrease on bare filters. Salt-coated filters proved highly effective in deactivating influenza viruses regardless of subtypes and following storage in harsh environmental conditions. Our results can be applied in obtaining a broad-spectrum, airborne pathogen prevention device in preparation for epidemic and pandemic of respiratory diseases. PMID:28051158
Schmidt, Carsten K; Brauch, Heinz-Jürgen
2008-09-01
Application and microbial degradation of the fungicide tolylfluanide gives rise to a new decomposition product named N,N-dimethylsulfamide (DMS). In Germany, DMS was found in groundwaters and surface waters with typical concentrations in the range of 100-1000 ng/L and 50-90 ng/L, respectively. Laboratory-scale and field investigations concerning its fate during drinking water treatment showed that DMS cannot be removed via riverbank filtration, activated carbon filtration, flocculation, and oxidation or disinfection procedures based on hydrogen peroxide, potassium permanganate, chlorine dioxide, or UV irradiation. Even nanofiltration does not provide a sufficient removal efficiency. During ozonation about 30-50% of DMS are converted to the carcinogenic N-nitrosodimethylamine (NDMA). The NDMA being formed is biodegradable and can at least partially be removed by subsequent biologically active drinking water treatment steps including sand or activated carbon filtration. Disinfection with hypochlorous acid converts DMS to so far unknown degradation products but not to NDMA or 1,1-dimethylhydrazine (UDMH).
Printed microfluidic filter for heparinized blood.
Bilatto, Stanley E R; Adly, Nouran Y; Correa, Daniel S; Wolfrum, Bernhard; Offenhäusser, Andreas; Yakushenko, Alexey
2017-05-01
A simple lab-on-a-chip method for blood plasma separation was developed by combining stereolithographic 3D printing with inkjet printing, creating a completely sealed microfluidic device. In some approaches, one dilutes the blood sample before separation, reducing the concentration of a target analyte and increasing a contamination risk. In this work, a single drop (8 μ l) of heparinized whole blood could be efficiently filtered using a capillary effect without any external driving forces and without dilution. The blood storage in heparin tubes during 24 h at 4 °C initiated the formation of small crystals that formed auto-filtration structures in the sample upon entering the 3D-printed device, with pores smaller than the red blood cells, separating plasma from the cellular content. The total filtration process took less than 10 s. The presented printed plasma filtration microfluidics fabricated with a rapid prototyping approach is a miniaturized, fast and easy-to-operate device that can be integrated into healthcare/portable systems for point-of-care diagnostics.
Immunoadsorption in Anti-GBM Glomerulonephritis: Case Report in a Child and Literature Review.
Dorval, Guillaume; Lion, Mathilde; Guérin, Sophie; Krid, Saoussen; Galmiche-Rolland, Louise; Salomon, Rémi; Boyer, Olivia
2017-11-01
Antiglomerular basement membrane glomerulonephritis (anti-GBM GN) is a rare autoimmune disease that is characterized by rapidly progressive glomerulonephritis that may be associated with pulmonary hemorrhage. Anti-GBM GN is caused by autoantibodies (classically type G immunoglobulin) directed against the α3 subunit of type IV collagen. Without any appropriate treatment, the disease is generally fulminant, and patient and kidney survival is poor. The current guidelines recommend the use of plasma exchanges and immunosuppressive drugs. Immunoadsorption (IA) can remove pathogenic IgGs from the circulation and do not require plasma infusions, contrary to plasma exchanges. IA has seldom been used in adult patients with good tolerance and efficiency. We report herein the first pediatric case successfully treated with IA combined with immunosuppressive drugs in a 7-year-old girl who presented acute kidney injury (estimated glomerular filtration rate 38 mL/minute/1.73 m 2 ). A kidney biopsy revealed numerous >80% glomerular crescents and linear IgG deposits along the glomerular basement membrane. Ten IA sessions led to rapid and sustained clearance of autoantibodies and improvement of kidney function until 21 months after onset (glomerular filtration rate 87 mL/minute/1.73 m 2 ). No adverse effect was noted. This report adds to the growing body of evidence suggesting IA as a therapeutic alternative to plasma exchanges in anti-GBM GN. The other 27 published pediatric cases of anti-GBM GN are reviewed. Copyright © 2017 by the American Academy of Pediatrics.
Particle loading rates for HVAC filters, heat exchangers, and ducts.
Waring, M S; Siegel, J A
2008-06-01
The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.
Comparing viral metagenomics methods using a highly multiplexed human viral pathogens reagent
Li, Linlin; Deng, Xutao; Mee, Edward T.; Collot-Teixeira, Sophie; Anderson, Rob; Schepelmann, Silke; Minor, Philip D.; Delwart, Eric
2014-01-01
Unbiased metagenomic sequencing holds significant potential as a diagnostic tool for the simultaneous detection of any previously genetically described viral nucleic acids in clinical samples. Viral genome sequences can also inform on likely phenotypes including drug susceptibility or neutralization serotypes. In this study, different variables of the laboratory methods often used to generate viral metagenomics libraries on the efficiency of viral detection and virus genome coverage were compared. A biological reagent consisting of 25 different human RNA and DNA viral pathogens was used to estimate the effect of filtration and nuclease digestion, DNA/RNA extraction methods, pre-amplification and the use of different library preparation kits on the detection of viral nucleic acids. Filtration and nuclease treatment led to slight decreases in the percentage of viral sequence reads and number of viruses detected. For nucleic acid extractions silica spin columns improved viral sequence recovery relative to magnetic beads and Trizol extraction. Pre-amplification using random RT-PCR while generating more viral sequence reads resulted in detection of fewer viruses, more overlapping sequences, and lower genome coverage. The ScriptSeq library preparation method retrieved more viruses and a greater fraction of their genomes than the TruSeq and Nextera methods. Viral metagenomics sequencing was able to simultaneously detect up to 22 different viruses in the biological reagent analyzed including all those detected by qPCR. Further optimization will be required for the detection of viruses in biologically more complex samples such as tissues, blood, or feces. PMID:25497414
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A
Purpose: The purpose of this investigation was to quantify percent depth dose (PDD) curves for fluoroscopic x-ray beam qualities incorporating added copper filtration. Methods: A PTW (Freiburg, Germany) MP3 water tank was used with a Standard Imaging (Middleton, WI) Exradin Model 11 Spokas Chamber to measure PDD curves for 60, 80, 100 and 120 kVp x-ray beams with copper filtration ranging from 0.0–0.9 mm at 22cm and 42cm fields of view from 0 to 150 mm of water. A free-in-air monitor chamber was used to normalize the water tank data to fluctuations in output from the fluoroscope. The measurements weremore » acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope. The fluoroscope was inverted from the typical orientation providing an x-ray beam originating from above the water tank. The water tank was positioned so that the water level was located at 60cm from the focal spot; which also represents the focal spot to interventional reference plane distance for that fluoroscope. Results: PDDs for 60, 80, 100, and 120 kVp with 0 mm of copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)] for those beam qualities given differences in fluoroscopes, geometric orientation, type of ionization chamber, and the water tank used for data collection. PDDs for 60, 80, 100, and 120 kVp with copper filtration were obtained and are presented, which have not been previously investigated and published. Conclusion: The equipment and processes used to acquire the reported data were sound and compared well with previously published data for PDDs without copper filtration. PDD data for the fluoroscopic x-ray beams incorporating copper filtration can be used as reference data for estimating organ or soft tissue dose at depth involving similar beam qualities or for comparison with mathematical models.« less
Tran, Dinh Minh; Clément-Demange, André; Déon, Marine; Garcia, Dominique; Le Guen, Vincent; Clément-Vidal, Anne; Soumahoro, Mouman; Masson, Aurélien; Label, Philippe; Le, Mau Tuy; Pujade-Renaud, Valérie
2016-01-01
An indirect phenotyping method was developed in order to estimate the susceptibility of rubber tree clonal varieties to Corynespora Leaf Fall (CLF) disease caused by the ascomycete Corynespora cassiicola. This method consists in quantifying the impact of fungal exudates on detached leaves by measuring the induced electrolyte leakage (EL%). The tested exudates were either crude culture filtrates from diverse C. cassiicola isolates or the purified cassiicolin (Cas1), a small secreted effector protein produced by the aggressive isolate CCP. The test was found to be quantitative, with the EL% response proportional to toxin concentration. For eight clones tested with two aggressive isolates, the EL% response to the filtrates positively correlated to the response induced by conidial inoculation. The toxicity test applied to 18 clones using 13 toxinic treatments evidenced an important variability among clones and treatments, with a significant additional clone x treatment interaction effect. A genetic linkage map was built using 306 microsatellite markers, from the F1 population of the PB260 x RRIM600 family. Phenotyping of the population for sensitivity to the purified Cas1 effector and to culture filtrates from seven C. cassiicola isolates revealed a polygenic determinism, with six QTL detected on five chromosomes and percentages of explained phenotypic variance varying from 11 to 17%. Two common QTL were identified for the CCP filtrate and the purified cassiicolin, suggesting that Cas1 may be the main effector of CCP filtrate toxicity. The CCP filtrate clearly contrasted with all other filtrates. The toxicity test based on Electrolyte Leakage Measurement offers the opportunity to assess the sensitivity of rubber genotypes to C. cassiicola exudates or purified effectors for genetic investigations and early selection, without risk of spreading the fungus in plantations. However, the power of this test for predicting field susceptibility of rubber clones to CLF will have to be further investigated.
Tran, Dinh Minh; Clément-Demange, André; Déon, Marine; Garcia, Dominique; Le Guen, Vincent; Clément-Vidal, Anne; Soumahoro, Mouman; Masson, Aurélien; Label, Philippe; Le, Mau Tuy; Pujade-Renaud, Valérie
2016-01-01
An indirect phenotyping method was developed in order to estimate the susceptibility of rubber tree clonal varieties to Corynespora Leaf Fall (CLF) disease caused by the ascomycete Corynespora cassiicola. This method consists in quantifying the impact of fungal exudates on detached leaves by measuring the induced electrolyte leakage (EL%). The tested exudates were either crude culture filtrates from diverse C. cassiicola isolates or the purified cassiicolin (Cas1), a small secreted effector protein produced by the aggressive isolate CCP. The test was found to be quantitative, with the EL% response proportional to toxin concentration. For eight clones tested with two aggressive isolates, the EL% response to the filtrates positively correlated to the response induced by conidial inoculation. The toxicity test applied to 18 clones using 13 toxinic treatments evidenced an important variability among clones and treatments, with a significant additional clone x treatment interaction effect. A genetic linkage map was built using 306 microsatellite markers, from the F1 population of the PB260 x RRIM600 family. Phenotyping of the population for sensitivity to the purified Cas1 effector and to culture filtrates from seven C. cassiicola isolates revealed a polygenic determinism, with six QTL detected on five chromosomes and percentages of explained phenotypic variance varying from 11 to 17%. Two common QTL were identified for the CCP filtrate and the purified cassiicolin, suggesting that Cas1 may be the main effector of CCP filtrate toxicity. The CCP filtrate clearly contrasted with all other filtrates. The toxicity test based on Electrolyte Leakage Measurement offers the opportunity to assess the sensitivity of rubber genotypes to C. cassiicola exudates or purified effectors for genetic investigations and early selection, without risk of spreading the fungus in plantations. However, the power of this test for predicting field susceptibility of rubber clones to CLF will have to be further investigated. PMID:27736862
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
TEST QA PLAN FOR THE VERIFICATION TESTING OF BAGHOUSE FILTRATION PRODUCTS
Baghouses and their accompanying filter media are a leading particulate control technique for industrial sources. Increasingly emphasis on higher removal efficiencies has helped the baghouse to be even more competitive when compared to other control devices. At present there is n...
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
Li, Wen-Wei; Wang, Yun-Kun; Sheng, Guo-Ping; Gui, Yong-Xin; Yu, Lei; Xie, Tong-Qing; Yu, Han-Qing
2012-10-01
Conventional MBR has been mostly based on floc sludge and the use of costly microfiltration membranes. Here, a novel aerobic granule (AG)-mesh filter MBR (MMBR) process was developed for cost-effective wastewater treatment. During 32-day continuous operation, a predominance of granules was maintained in the system, and good filtration performance was achieved at a low trans-membrane pressure (TMP) of below 0.025 m. The granules showed a lower fouling propensity than sludge flocs, attributed to the formation of more porous biocake layer at mesh surface. A low-flux and low-TMP filtration favored a stable system operation. In addition, the reactor had high pollutant removal efficiencies, with a 91.4% chemical oxygen demand removal, 95.7% NH(4)(+) removal, and a low effluent turbidity of 4.1 NTU at the stable stage. This AG-MMBR process offers a promising technology for low-cost and efficient treatment of wastewaters. Copyright © 2012 Elsevier Ltd. All rights reserved.
Zhang, Yong-Gang; Zhu, Ying-Jie; Xiong, Zhi-Chao; Wu, Jin; Chen, Feng
2018-04-18
Inorganic aerogels have been attracting great interest owing to their distinctive structures and properties. However, the practical applications of inorganic aerogels are greatly restricted by their high brittleness and high fabrication cost. Herein, inspired by the cancellous bone, we have developed a novel kind of hydroxyapatite (HAP) nanowire-based inorganic aerogel with excellent elasticity, which is highly porous (porosity ≈ 99.7%), ultralight (density 8.54 mg/cm 3 , which is about 0.854% of water density), and highly adiabatic (thermal conductivity 0.0387 W/m·K). Significantly, the as-prepared HAP nanowire aerogel can be used as the highly efficient air filter with high PM 2.5 filtration efficiency. In addition, the HAP nanowire aerogel is also an ideal candidate for continuous oil-water separation, which can be used as a smart switch to separate oil from water continuously. Compared with organic aerogels, the as-prepared HAP nanowire aerogel is biocompatible, environmentally friendly, and low-cost. Moreover, the synthetic method reported in this work can be scaled up for large-scale production of HAP nanowires, free from the use of organic solvents. Therefore, the as-prepared new kind of HAP nanowire aerogel is promising for the applications in various fields.
Treatment of phosphate-containing oily wastewater by coagulation and microfiltration.
Zhang, Jin; Sun, Yu-xin; Huang, Zhi-feng; Liu, Xing-qin; Meng, Guang-yao
2006-01-01
The oily wastewater generated from pretreatment unit of electrocoating industry contains oils, phosphate, organic solvents, and surfactants. In order to improve the removal efficiencies of phosphate and oils, to mitigate the membrane fouling, coagulation for ceramic membrane microfiltration of oily wastewater was performed. The results of filtration tests show that the membrane fouling decreased and the permeate flux and quality increased with coagulation as pretreatment. At the coagulant Ca (OH)2 dosage of 900 mg/L, the removal efficiency of phosphate was increased from 46.4% without coagulation to 99.6%; the removal of COD and oils were 97.0% and 99.8%, respectively. And the permeate flux was about 70% greater than that when Ca(OH)2 was not used. The permeate obtained from coagulation and microfiltration can be reused as make-up water, and the recommended operation conditions for pilot and industrial application are transmembrane pressure of 0.10 MPa and cross-flow velocity of 5 m/s. The comparison results show that 0.2 microm ZrO2 microfilter with coagulation could be used to perform the filtration rather than conventional ultrafilter, with very substantial gain in flux and removal efficiency of phosphate.
Glomerular filtration rate and kidney size in type 2 (non-insulin-dependent) diabetes mellitus.
Wirta, O R; Pasternack, A I
1995-07-01
The objective of the present study was to estimate glomerular filtration rate and kidney size in recently diagnosed and long-term type 2 (non-insulin-dependent) diabetic subjects. The study design comprised of a population-based controlled cross-sectional survey of middle-aged type 2 diabetic subjects in the City of Tampere, Southwest Finland. One hundred and fifty consecutive recently diagnosed and 146 long-term middle-aged type 2 diabetic subjects with a disease duration of at least five years and one hundred and fifty age- and sex-matched (to recent diabetic subjects) non-diabetic control subjects were recruited. The glomerular filtration rate by single-shot 51Cr-EDTA clearance and kidney size by native X-ray tomography were measured. The glomerular filtration rate (ml/min/1.73 m2) was increased in both recently diagnosed (males 121 [27] and females 112 [27]) and long-term (males 123 [24] and females 102 [36]) diabetic subjects (corrected for age) compared to control subjects (males 111 [26] and females 93 [17]). The kidney areas (cm2) were greater in both recent diabetic (males 116.6 [15.4] and females 99.1 [15.3] and long-term diabetic (males 118.3 [15.8] and females 100.4 [15.2]) subjects than in the control group (males 104.3 [12.0] and females 88.6 [12.0]). All differences between diabetic subjects and non-diabetic subjects were statistically significant (p < 0.05), except that between long-term diabetic and non-diabetic females for glomerular filtration rate (p = 0.07). Analyzed by linear regression glomerular filtration rate was related to kidney area in all study groups and to hemoglobin A1c in long-term diabetic males.(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Bilyi, Olexander I.; Getman, Vasyl B.; Konyev, Fedir A.; Sapunkov, Olexander; Sapunkov, Pavlo G.
2001-06-01
The devices for monitoring of parameters of efficiency of water solutions filtration, which are based on the analysis of scattered light by microparticles are considered in this article. The efficiency of using of devices in pharmaceutics in technological processes of manufacturing medical injection solutions is shown. The examples of monitoring of contents of bacterial cultures Pseudomonas aeruginosa, Escherichia coli, and Micrococcus luteus in water solutions of glucose are indicated.
Andreoli, Fernando César; Sabogal-Paz, Lyda Patricia
2017-11-15
Removing protozoa from a water supply using coagulation, flocculation, dissolved air flotation (DAF) and filtration on a bench scale was evaluated. Calcium carbonate flocculation with and without immunomagnetic separation (IMS) was chosen to detect Giardia spp. cysts and Cryptosporidium spp. oocysts in the studied samples. The results indicated that DAF removed between 1.31 log and 1.79 log of cysts and between 1.08 log and 1.42 log of oocysts. The performance was lower in filtration, with the removal of 1.07 log-1.44 log for cysts and 0.82 log-0.98 log for oocysts. The coagulation, flocculation, DAF and filtration steps removed more than 2.2 log of cysts and oocysts from the water studied. However, protozoa were detected in the filtered water, even with turbidity values of 0.2 NTU. The recovery of the detection method met the international criteria and was higher when there was no IMS. Including the third acid dissociation in the IMS was critical to improve the performance of the protocol tested. However, there was an increase in the technical and analytical complexity and costs. It was also observed that the efficiency of the treatment was linked to the performance of the selected method of detecting protozoa.
Models for nearly every occasion: Part III - One box decreasing emission models.
Hewett, Paul; Ganser, Gary H
2017-11-01
New one box "well-mixed room" decreasing emission (DE) models are introduced that allow for local exhaust or local exhaust with filtered return, as well the recirculation of a filtered (or cleaned) portion of the general room ventilation. For each control device scenario, a steady state and transient model is presented. The transient equations predict the concentration at any time t after the application of a known mass of a volatile substance to a surface, and can be used to predict the task exposure profile, the average task exposure, as well as peak and short-term exposures. The steady state equations can be used to predict the "average concentration per application" that is reached whenever the substance is repeatedly applied. Whenever the beginning and end concentrations are expected to be zero (or near zero) the steady state equations can also be used to predict the average concentration for a single task with multiple applications during the task, or even a series of such tasks. The transient equations should be used whenever these criteria cannot be met. A structured calibration procedure is proposed that utilizes a mass balance approach. Depending upon the DE model selected, one or more calibration measurements are collected. Using rearranged versions of the steady state equations, estimates of the model variables-e.g., the mass of the substance applied during each application, local exhaust capture efficiency, and the various cleaning or filtration efficiencies-can be calculated. A new procedure is proposed for estimating the emission rate constant.
Pervaporation • Membrane-based separation process • Not filtration Separation based on solution-diffusion transport through non-porous or “molecularly-porous” membrane Permeate is a vapor • Permeate contains only volatile compounds • Able to separate mixtures of mis...
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than 10 micrometers. The APCT Verification Center...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wenjun Qin; Manuel Dekermenjian; Richard J. Martin
2006-08-15
Loss of filtration efficiency in a fabric filter baghouse is typically caused by bag failure, in one form or another. The degree of such failure can be as minor as a pinhole leak or as major as a fully involved baghouse fire. In some cases, local air pollution regulations or federal hazardous waste laws may require estimation of the total quantity of particulate matter released to the environment as a result of such failures. In this paper, a technique is presented for computing the dust loading in the baghouse exhaust when one or more bags have failed. The algorithm developedmore » is shown to be an improvement over a previously published result, which requires empirical knowledge of the variation in baghouse pressure differential with bag failures. An example calculation is presented for a baghouse equipped with 200 bags. The prediction shows that a small percentage of failed bags can cause a relatively large proportion of the gas flow to bypass the active bags, which, in turn, leads to high outlet dust loading and low overall collection efficiency from the baghouse. 10 refs., 5 figs., 3 tabs.« less
Juge, Pierre-Antoine; Truchetet, Marie-Elise; Pillebout, Evangeline; Ottaviani, Sébastien; Vigneau, Cécile; Loustau, Clotilde; Cornec, Divi; Pascart, Tristan; Snanoudj, Renaud; Bailly, Florian; Cornec-Le Gall, Emilie; Schaeverbeke, Thierry; Saraux, Alain; Dieudé, Philippe; Flipo, René-Marc; Richette, Pascal; Lioté, Frédéric; Bardin, Thomas; Chalès, Gérard; Ea, Hang-Korng
2017-10-01
The allopurinol dose is limited in chronic kidney disease, particularly stage 4/5 chronic kidney disease. Febuxostat has a hepatic metabolism and has been approved without dose adaptation in gouty patients with stage 1-3 chronic kidney disease. We aimed to study the safety and efficacy of febuxostat for stage 4/5 chronic kidney disease. In this retrospective study, we included patients with (1) a diagnosis of gout, (2) febuxostat treatment, (3) estimated glomerular filtration rate≤30mL/min/1.73m 2 (Modification of Diet in Renal Disease formula) at febuxostat initiation and (4) follow-up for at least 3 months after febuxostat initiation. Efficacy, safety and variation in estimated glomerular filtration rate were analyzed. We included 73 patients (mean age 70.2±11.8, 61 men, 31 with vascular chronic kidney disease and 18 renal transplantation) with gout (baseline serum uric acid level=9.86±2.85mg/dL, mean gout duration 6.2±7.0 years) from 10 academic centers. Comorbidities included cardiac failure (17.8%), hypertension (98.6%), diabetes mellitus (30.1%), dyslipidemia (64.8%) and history of cardiovascular events (38.4%). At the last visit (mean follow-up 68.5±64.8 weeks), the daily dose of febuxostat was 40mg for 7 patients (10.5%), 80mg for 50 (74.6%) and 120mg for 10 (14.9%). Serum uric acid level was<6mg/dL for 49 patients (67%). Renal function improved for 18 patients, was unchanged for 24 and worsened for 31; 19 patients experienced flares and 1 patient, limb edema. Febuxostat seemed efficient in gouty patients with stage 4/5 chronic kidney disease. However, safety data were not clear regarding renal function. Larger studies are needed to assess safety. Copyright © 2016 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delincee, H.
1978-01-01
Industrial dry fungal pectinase from A. niger was irradiated with doses (up to 1 Mrad) of /sup 60/Co-..gamma..rays effective in reducing microbial contamination. The pectinase was characterized by thin-layer isoelectric focusing and gel filtration in order to detect possible radiation-induced structural alterations. Thin-layer isoelectric focusing revealed at least fifteen multiple forms with pectin-depolymerizing activity, with isoelectric points in the range pH 4.5 to 7. Heterogeneity of pectinesterase was also demonstrated, the main band occurring around pH 4. By thin-layer gel filtration the molecular weight of the pectin-depolymerase was estimated as being about 36,000, and that of pectinesterase as about 33,000.more » Radiation-induced changes of the charge properties or molecular size of the irradiated pectinase preparation were not observed. The feasibility of using ionizing radiation for the reduction of microbial contamination of industrial enzyme preparations looks promising.« less
Lantagne, Daniele S.; Cardinali, Fred; Blount, Ben C.
2010-01-01
Almost a billion persons lack access to improved drinking water, and diarrheal diseases cause an estimated 1.87 million deaths per year. Sodium dichloroisocyanurate (NaDCC) tablets are widely recommended for household water treatment to reduce diarrhea. Because NaDCC is directly added to untreated water sources, concerns have been raised about the potential health impact of disinfection by-products. This study investigated trihalomethane (THM) production in water from six sources used for drinking (0.6–888.5 nephelometric turbidity units) near Arusha, Tanzania. No sample collected at 1, 8, and 24 hours after NaDCC addition exceeded the World Health Organization guideline values for either individual or total THMs. Ceramic filtration, sand filtration, cloth filtration, and settling and decanting were not effective mitigation strategies to reduce THM formation. Chlorine residual and THM formation were not significantly different in NaDCC and sodium hypochlorite treatment. Household chlorination of turbid and non-turbid waters did not create THM concentrations that exceeded health risk guidelines. PMID:20595492
Jha, Ashish Kumar
2015-01-01
Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.
Horká, Marie; Horký, Jaroslav; Kubesová, Anna; Zapletalová, Eva; Slais, Karel
2011-07-01
Trace analysis of microorganisms in real biological samples needs very sensitive methods for their detection. Most procedures for detecting and quantifying pathogens require a sample preparation step including concentrating microorganisms from large sample volumes with high and reproducible efficiency. Electromigration techniques have great potential to include the preconcentration, separation, and detection of whole cells and therefore they can rapidly indicate the presence of pathogens. The preconcentration and separation of microorganisms from real suspensions utilising a combination of filtration and capillary isoelectric focusing was developed and the possibility for its application to real samples was verified. For our experiments, spores of Monilinia species and of Penicillium expansum were selected as model bioparticles, as they cause major losses in agrosystems. The isoelectric points of the spores of M. laxa, M. fructigena, M. fruticola, and P. expansum were determined and the method was verified using real samples taken directly from infected apples. The coupling of a filtration cartridge with a separation capillary can improve the detection limit of isoelectric focusing with UV detection by at least 4 orders of magnitude. Spores of M. fructigena and of M. laxa in numbers of hundreds of particles per milliliter were detected on a visually noninfected apple surface which was cross-contaminated during handling and storage. The efficiency of preconcentration and a preliminary identification was verified by the phenotyping technique after cultivation of the spores sampled from the apple surface.
Fluid and solute transfer characteristics in a dialyzer with a high-performance membrane.
Mineshima, Michio
2011-01-01
To date, many types of high-flux dialyzers with high-performance membranes have been developed. They seem to have a higher internal filtration flow rate (Q(IF)) because of a higher ultrafiltration coefficient. In the health reimbursement system in Japan, commercially available dialyzers are categorized into five types based on their β(2)-microglobulin clearance (K(BMG)) values. Although the K(BMG) value was not correlated strongly with the Q(IF) value for 26 types of commercially available dialyzers, almost all the dialyzers with a higher Q(IF) value had a higher KBMG value. These dialyzers seem to have a higher convective transport because of internal filtration in addition to diffusive transport. We measured the blood flow velocity in a cross-sectional plane of the dialyzer using pulse Doppler ultra-sonography to evaluate QIF. It is a useful method for the bedside monitoring because it is noninvasive to the patient and produces reliable data with a higher reproducibility. On the other hand, membrane fouling occurs more easily in higher Q(IF) dialyzers, compared with conventional dialyzers, because of the higher degree of membrane fouling. Internal filtration-enhanced hemodialysis (IFEHD) using these dialyzers, therefore, has the advantage of increasing solute removal efficiency by enhancing convective transport and the simultaneous disadvantage of decreasing solute removal efficiency by causing membrane fouling. Thus, IFEHD treatment should be performed using a dialyzer with a high-performance membrane to ensure that the advantage is superior to the disadvantage. Copyright © 2011 S. Karger AG, Basel.
Portable Nanomesh Creates Safer Drinking Water
NASA Technical Reports Server (NTRS)
2008-01-01
Providing astronauts with clean water is essential to space exploration to ensure the health and well-being of crewmembers away from Earth. For the sake of efficient and safe long-term space travel, NASA constantly seeks to improve the process of filtering and re-using wastewater in closed-loop systems. Because it would be impractical for astronauts to bring months (or years) worth of water with them, reducing the weight and space taken by water storage through recycling and filtering as much water as possible is crucial. Closed-loop systems using nanotechnology allow wastewater to be cleaned and reused while keeping to a minimum the amount of drinking water carried on missions. Current high-speed filtration methods usually require electricity, and methods without electricity usually prove impractical or slow. Known for their superior strength and electrical conductivity, carbon nanotubes measure only a few nanometers in diameter; a nanometer is one billionth of a meter, or roughly one hundred-thousandth the width of a human hair. Nanotubes have improved water filtration by eliminating the need for chemical treatments, significant pressure, and heavy water tanks, which makes the new technology especially appealing for applications where small, efficient, lightweight materials are required, whether on Earth or in space. "NASA will need small volume, effective water purification systems for future long-duration space flight," said Johnson Space Center s Karen Pickering. NASA advances in water filtration with nanotechnology are now also protecting human health in the most remote areas of Earth.
Effectiveness of in-room air filtration and dilution ventilation for tuberculosis infection control.
Miller-Leiden, S; Lobascio, C; Nazaroff, W W; Macher, J M
1996-09-01
Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.
Effectiveness of In-Room Air Filtration and Dilution Ventilation for Tuberculosis Infection Control.
Miller-Leiden, S; Lohascio, C; Nazaroff, W W; Macher, J M
1996-09-01
Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.
NASA Astrophysics Data System (ADS)
de Tullio, Marco D.; Singh, Jaykrishna; Pascazio, Giuseppe; Decuzzi, Paolo
2014-03-01
Vascular targeted nanoparticles have been developed for the delivery of therapeutic and imaging agents in cancer and cardiovascular diseases. However, at authors' knowledge, a comprehensive systematic analysis on their delivery efficiency is still missing. Here, a computational model is developed to predict the vessel wall accumulation of agents released from vascular targeted nanoconstructs. The transport problem for the released agent is solved using a finite volume scheme in terms of three governing parameters: the local wall shear rate , ranging from to ; the wall filtration velocity , varying from to ; and the agent diffusion coefficient , ranging from to . It is shown that the percentage of released agent adsorbing on the vessel walls in the vicinity of the vascular targeted nanoconstructs reduces with an increase in shear rate , and with a decrease in filtration velocity and agent diffusivity . In particular, in tumor microvessels, characterized by lower shear rates () and higher filtration velocities (), an agent with a diffusivity (i.e. a 50 nm particle) is predicted to deposit on the vessel wall up to of the total released dose. Differently, drug molecules, exhibiting a smaller size and much higher diffusion coefficient (), are predicted to accumulate up to . In healthy vessels, characterized by higher and lower , the largest majority of the released agent is redistributed directly in the circulation. These data suggest that drug molecules and small nanoparticles only can be efficiently released from vascular targeted nanoconstructs towards the diseased vessel walls and tissue.
NASA Technical Reports Server (NTRS)
Green, Robert D.; Agui, Juan H.; Vijayakumar, R.; Berger, Gordon M.; Perry, Jay L.
2017-01-01
The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.
Filter Efficiency and Pressure Testing of Returned ISS Bacterial Filter Elements (BFEs)
NASA Technical Reports Server (NTRS)
Green, Robert D.; Agui, Juan H.; Berger, Gordon M.; Vijayakumar, R.; Perry, Jay L.
2017-01-01
The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.
Removal of heavy metals from water with forest based materials
James D. McSweeny; Roger M. Rowell; George C. Chen; Thomas L. Eberhardt; Soo-Hong Min
2006-01-01
For 1.5 to 2.5 billion people in the world, clean water is a critical issue (Lepkowski 1999). In the U.S., it is estimated that 90% of all Americans live within 10 miles of a body of contaminated water (Hogue, 2000). The development of filters to clean our water supply is big business. It is estimated that global spending on filtration (including dust collectors, air...
Benefits, Harms, and Costs of Osteoporosis Screening in Male Veterans
2015-10-01
K Lyles, J LaFleur, C VanHoutven, C Pieper – accepted to American Geriatrics Society Annual Meeting, May 2016 Background: Practice guidelines...Veterans. Rasheeda K. Hall, Richard Sloane, Carl Pieper, Cathleen Colón-Emeric. – accepted to American Geriatrics Society Annual Meeting, May 2016...who had no prior diagnoses of fracture or osteoporosis therapy . Estimated glomerular filtration rate (eGFR) was estimated using baseline creatinine
Kidney Function in Obesity-Challenges in Indexing and Estimation.
Chang, Alex R; Zafar, Waleed; Grams, Morgan E
2018-01-01
As the prevalence of obesity continues to increase worldwide, an increasing number of people are at risk for kidney disease. Thus, there is a critical need to understand how best to assess kidney function in this population, and several challenges exist. The convention of indexing glomerular filtration rate (GFR) to body surface area (BSA) attempts to normalize exposure to metabolic wastes across populations of differing body size. In obese individuals, this convention results in a significantly lower indexed GFR than unindexed GFR, which has practical implications for drug dosing. Recent data suggest that "unindexing" estimated GFR (multiplying by BSA/1.73 m 2 ) for drug dosing may be acceptable, but pharmocokinetic data to support this practice are lacking. Beyond indexing, biomarkers commonly used for estimating GFR may induce bias. Creatinine is influenced by muscle mass, whereas cystatin C correlates with fat mass, both independent of kidney function. Further research is needed to evaluate the performance of estimating equations and other filtration markers in obesity, and determine whether unindexed GFR might better predict optimal drug dosing and clinical outcomes in patients whose BSA is very different than the conventional normalized value of 1.73 m 2 . Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
The applicability of eGFR equations to different populations.
Delanaye, Pierre; Mariat, Christophe
2013-09-01
The Cockcroft-Gault equation for estimating glomerular filtration rate has been learnt by every generation of medical students over the decades. Since the publication of the Modification of Diet in Renal Disease (MDRD) study equation in 1999, however, the supremacy of the Cockcroft-Gault equation has been relentlessly disputed. More recently, the Chronic Kidney Disease Epidemiology (CKD-EPI) consortium has proposed a group of novel equations for estimating glomerular filtration rate (GFR). The MDRD and CKD-EPI equations were developed following a rigorous process, are expressed in a way in which they can be used with standardized biomarkers of GFR (serum creatinine and/or serum cystatin C) and have been evaluated in different populations of patients. Today, the MDRD Study equation and the CKD-EPI equation based on serum creatinine level have supplanted the Cockcroft-Gault equation. In many regards, these equations are superior to the Cockcroft-Gault equation and are now specifically recommended by international guidelines. With their generalized use, however, it has become apparent that those equations are not infallible and that they fail to provide an accurate estimate of GFR in certain situations frequently encountered in clinical practice. After describing the processes that led to the development of the new GFR-estimating equations, this Review discusses the clinical situations in which the applicability of these equations is questioned.
Katulska, Katarzyna; Milewska, Agata; Wykretowicz, Mateusz; Krauze, Tomasz; Przymuszala, Dagmara; Piskorski, Jaroslaw; Stajgis, Marek; Guzik, Przemyslaw; Wysocki, Henryk; Wykrętowicz, Andrzej
2013-10-01
Left atrial (LA) size is an important predictor of stroke, death, and atrial fibrillation. It was demonstrated recently that body fat, arterial stiffness and renal functions are associated with LA diameter. However, data are lacking for comprehensive assessments of all these risk factors in a single population. Therefore, the aim of the present study was to investigate the association between LA size and different fat descriptors, central hemodynamics, arterial stiffness, and renal function in healthy subjects. To this end, body fat percentage, abdominal, subcutaneous fat, and general descriptors of body fat were estimated in 162 healthy subjects (mean age 51 years). Echocardiography was performed to assess LA diameter. Arterial stiffness and peripheral and central hemodynamics were estimated by digital volume pulse analysis and pulse wave analysis. Glomerular filtration rate was estimated by MDRD formula. There were significant (p < 0.05) bivariate correlations between LA diameter and all descriptors of body fat (except subcutaneous fat). Arterial stiffness and estimated glomerular filtration rate (eGFR) were also significantly correlated with LA size. Multiple regression analysis including all significant confounders, such as sex, mean arterial pressure, arterial stiffness, eGFR and body fat descriptors, explained 35% of variance in LA diameter. In conclusion, the present study reveals significant, independent relationships between body fat, arterial stiffness, and LA size.
Water recovery in a concentrated solar power plant
NASA Astrophysics Data System (ADS)
Raza, Aikifa; Higgo, Alex R.; Alobaidli, Abdulaziz; Zhang, TieJun
2016-05-01
For CSP plants, water consumption is undergoing increasing scrutiny particularly in dry and arid regions with water scarcity conditions. Significant amount of water has to be used for parabolic trough mirror cleaning to maintain high mirror reflectance and optical efficiency in sandy environment. For this specific purpose, solar collectors are washed once or twice every week at Shams 1, one of the largest CSP plant in the Middle East, and about 5 million gallons of demineralized water is utilized every year without further recovery. The produced waste water from a CSP plant contains the soiling i.e. accumulated dust and some amount of organic contaminants, as indicated by our analysis of waste water samples from the solar field. We thus need to develop a membrane based system to filter fine dust particulates and to degrade organic contaminant simultaneously. Membrane filtration technology is considered to be cost-effective way to address the emerging problem of a clean water shortage, and to reuse the filtered water after cleaning solar collectors. But there are some major technical barriers to improve the robustness and energy efficiency of filtration membranes especially when dealing with the removal of ultra-small particles and oil traces. Herein, we proposed a robust and scalable nanostructured inorganic microporous filtration copper mesh. The inorganic membrane surface wettability is tailored to enhance the water permeability and filtration flux by creating nanostructures. These nanostructured membranes were successfully employed to recover water collected after cleaning the reflectors of solar field of Shams 1. Another achievement was to remove the traces of heat transfer fluid (HTF) from run-off water which was collected after accidental leakage in some of the heat exchangers during the commissioning of the Shams 1 for safe disposal into the main stream. We hope, by controlling the water recovery factor and membrane reusability performance, the membrane design could be used for water conservation in CSP plants.
9 CFR 590.146 - Application for continuous inspection in official plants; approval.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., lockers, and toilets. The prints shall show slope of floors to drains. (6) The official plant shall..., toilet and dressing rooms, storerooms for supplies, and all other rooms, compartments, or passageways... systems, description of pasteurizer, description of drier, type and efficiency of air filtration, hot...
9 CFR 590.146 - Application for continuous inspection in official plants; approval.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., lockers, and toilets. The prints shall show slope of floors to drains. (6) The official plant shall..., toilet and dressing rooms, storerooms for supplies, and all other rooms, compartments, or passageways... systems, description of pasteurizer, description of drier, type and efficiency of air filtration, hot...
9 CFR 590.146 - Application for continuous inspection in official plants; approval.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., lockers, and toilets. The prints shall show slope of floors to drains. (6) The official plant shall..., toilet and dressing rooms, storerooms for supplies, and all other rooms, compartments, or passageways... systems, description of pasteurizer, description of drier, type and efficiency of air filtration, hot...
9 CFR 590.146 - Application for continuous inspection in official plants; approval.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., lockers, and toilets. The prints shall show slope of floors to drains. (6) The official plant shall..., toilet and dressing rooms, storerooms for supplies, and all other rooms, compartments, or passageways... systems, description of pasteurizer, description of drier, type and efficiency of air filtration, hot...
The relative efficiencies of a buffered beef extract solution, sewage secondary effluent, and distilled water, were compared in a study designed to simulate leaching of indigenous enteric viruses from raw primary sewage sludge. The initial sludge liquid fractions, termed sludge l...
The Role of Microbial Processes in the Oxidation and Removal of Ammonia from Drinking Water
The purpose of this study was two-fold: (1) to monitor and evaluate nitrification in a full-scale iron removal filtration plant with biologically active granular media filters located in Ohio, and (2) to determine how to most efficiently regain nitrification following filter rebe...
Removal of waterborne microorganisms by filtration using clay-polymer complexes.
Undabeytia, Tomas; Posada, Rosa; Nir, Shlomo; Galindo, Irene; Laiz, Leonila; Saiz-Jimenez, Cesareo; Morillo, Esmeralda
2014-08-30
Clay-polymer composites were designed for use in filtration processes for disinfection during the course of water purification. The composites were formed by sorption of polymers based on starch modified with quaternary ammonium ethers onto the negatively charged clay mineral bentonite. The performance of the clay-polymer complexes in removal of bacteria was strongly dependent on the conformation adopted by the polycation on the clay surface, the charge density of the polycation itself and the ratio between the concentrations of clay and polymer used during the sorption process. The antimicrobial effect exerted by the clay-polymer system was due to the cationic monomers adsorbed on the clay surface, which resulted in a positive surface potential of the complexes and charge reversal. Clay-polymer complexes were more toxic to bacteria than the polymers alone. Filtration employing our optimal clay-polymer composite yielded 100% removal of bacteria after the passage of 3L, whereas an equivalent filter with granular activated carbon (GAC) hardly yielded removal of bacteria after 0.5L. Regeneration of clay-polymer complexes saturated with bacteria was demonstrated. Modeling of the filtration processes permitted to optimize the design of filters and estimation of experimental conditions for purifying large water volumes in short periods. Copyright © 2014 Elsevier B.V. All rights reserved.
Tanagho, Youssef S; Bhayani, Sam B; Sandhu, Gurdarshan S; Vaughn, Nicholas P; Nepple, Kenneth G; Figenshau, R Sherburne
2012-10-01
To evaluate the potential benefit of performing off-clamp robot-assisted partial nephrectomy as it relates to renal functional outcomes, while assessing the safety profile of this unconventional surgical approach. Twenty-nine patients who underwent off-clamp robot-assisted partial nephrectomy for suspected renal cell carcinoma at Washington University between March 2008 and September 2011 (group 1) were matched to 29 patients with identical nephrometry scores and comparable baseline renal function who underwent robot-assisted partial nephrectomy with hilar clamping during the same period (group 2). The matched cohorts' perioperative and renal functional outcomes were compared at a mean 9-month follow-up. Mean estimated blood loss was 146.4 mL in group 1, versus 103.9 mL in group 2 (P = .039). Mean hilar clamp time was 0 minutes in group 1 and 14.7 minutes in group 2. No perioperative complications were encountered in group 1; 1 Clavien-2 complication (3.4%) occurred in group 2 (P = 1.000). At 9-month follow-up, mean estimated glomerular filtration rate in group 1 was 79.9 versus 84.8 mL/min/1.73 m(2) preoperatively (P = .013); mean estimated glomerular filtration rate in group 2 was 74.1 versus 85.8 mL/min/1.73 m(2) preoperatively (P < .001). Hence, estimated glomerular filtration rate declined by a mean of 4.9 mL/min/1.73 m(2) in group 1 versus 11.7 mL/min/1.73 m(2) in group 2 (P = .033). Off-clamp robot-assisted partial nephrectomy is associated with a favorable morbidity profile and relatively greater renal functional preservation compared to clamped robot-assisted partial nephrectomy. Nevertheless, the benefit is small in renal functional terms and may have very limited clinical relevance. Copyright © 2012 Elsevier Inc. All rights reserved.
Spector, June T.; Navas-Acien, Ana; Fadrowski, Jeffrey; Guallar, Eliseo; Jaar, Bernard
2011-01-01
Background. Low-level lead exposure is widespread and has been implicated as a chronic kidney disease (CKD) risk factor. However, studies evaluating associations of lead dose with newer, potentially more accurate, estimates of kidney function, in participants with a wide range of glomerular filtration rates (GFRs), are scarce. Methods. We compared associations of blood lead and estimated glomerular filtration rate (eGFR) using the Modification of Diet in Renal Disease (MDRD), Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) and cystatin C single variable, multivariable and combined creatinine/cystatin C equations in 3941 adults who participated in the 1999–2002 National Health and Nutrition Examination Survey cystatin C subsample. Results. Geometric mean blood lead was 1.7 μg/dL. After multivariable adjustment, differences [95% confidence interval (CI)] in mean eGFR for a doubling of blood lead were −1.9 (−3.2, −0.7), −1.7 (−3.0, −0.5) and −1.4 (−2.3, −0.5) mL/min/1.73 m2, using the cystatin C single variable, multivariable and combined creatinine/cystatin C equations, respectively, reflecting lower eGFR with increased blood lead. The corresponding differences (95% CI) were −0.9 (−1.9, 0.02) and −0.9 (−1.8, 0.01) using the creatinine-based MDRD and CKD-EPI equations, respectively. In participants aged ≥60 years, differences in mean eGFR ranged from −3.0 to −4.5 mL/min/1.73 m2, and odds of reduced eGFR (<60 mL/min/1.73 m2) were increased for all estimates of GFR. Conclusions. These results support the inclusion of cystatin C-based eGFR in future lead research and provide additional evidence for environmental lead exposure as a CKD risk factor. PMID:21248295
Hsieh, Po-Fan; Wang, Yu-De; Huang, Chi-Ping; Wu, Hsi-Chin; Yang, Che-Rei; Chen, Guang-Heng; Chang, Chao-Hsiang
2016-07-01
We proposed a mathematical formula to calculate contact surface area between a tumor and renal parenchyma. We examined the applicability of using contact surface area to predict renal function after partial nephrectomy. We performed this retrospective study in patients who underwent partial nephrectomy between January 2012 and December 2014. Based on abdominopelvic computerized tomography or magnetic resonance imaging, we calculated the contact surface area using the formula (2*π*radius*depth) developed by integral calculus. We then evaluated the correlation between contact surface area and perioperative parameters, and compared contact surface area and R.E.N.A.L. (Radius/Exophytic/endophytic/Nearness to collecting system/Anterior/Location) score in predicting a reduction in renal function. Overall 35, 26 and 45 patients underwent partial nephrectomy with open, laparoscopic and robotic approaches, respectively. Mean ± SD contact surface area was 30.7±26.1 cm(2) and median (IQR) R.E.N.A.L. score was 7 (2.25). Spearman correlation analysis showed that contact surface area was significantly associated with estimated blood loss (p=0.04), operative time (p=0.04) and percent change in estimated glomerular filtration rate (p <0.001). On multivariate analysis contact surface area and R.E.N.A.L. score independently affected percent change in estimated glomerular filtration rate (p <0.001 and p=0.03, respectively). On ROC curve analysis contact surface area was a better independent predictor of a greater than 10% change in estimated glomerular filtration rate compared to R.E.N.A.L. score (AUC 0.86 vs 0.69). Using this simple mathematical method, contact surface area was associated with surgical outcomes. Compared to R.E.N.A.L. score, contact surface area was a better predictor of functional change after partial nephrectomy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Karimzadeh, Iman; Khalili, Hossein
2016-06-06
Serum cystatin C (Cys C) has a number of advantages over serum creatinine in the evaluation of kidney function. Apart from Cys C level itself, several formulas have also been introduced in different clinical settings for the estimation of glomerular filtration rate (GFR) based upon serum Cys C level. The aim of the present study was to compare a serum Cys C-based equation with Cockcroft-Gault serum creatinine-based formula, both used in the calculation of GFR, in patients receiving amphotericin B. Fifty four adult patients with no history of acute or chronic kidney injury having been planned to receive conventional amphotericin B for an anticipated duration of at least 1 week for any indication were recruited. At three time points during amphotericin B treatment, including days 0, 7, and 14, serum cystatin C as well as creatinine levels were measured. GFR at the above time points was estimated by both creatinine (Cockcroft-Gault) and serum Cys C based equations. There was significant correlation between creatinine-based and Cys C-based GFR values at days 0 (R = 0.606, P = 0.001) and 7 (R = 0.714, P < 0.001). In contrast to GFR estimated by the Cockcroft-Gault equation, the mean (95 % confidence interval) Cys C-based GFR values at different studied time points were comparable within as well as between patients with and without amphotericin B nephrotoxicity. Our results suggested that the Gentian Cys C-based GFR equation correlated significantly with the Cockcroft-Gault formula at least at the early time period of treatment with amphotericin B. Graphical abstract Comparison between a serum creatinine-and a cystatin C-based glomerular filtration rate equation in patients receiving amphotericin B.
Prognostic Nutritional Index and the Risk of Mortality in Patients With Acute Heart Failure.
Cheng, Yu-Lun; Sung, Shih-Hsien; Cheng, Hao-Min; Hsu, Pai-Feng; Guo, Chao-Yu; Yu, Wen-Chung; Chen, Chen-Huan
2017-06-25
Nutritional status has been related to clinical outcomes in patients with heart failure. We assessed the association between nutritional status, indexed by prognostic nutritional index (PNI), and survival in patients hospitalized for acute heart failure. A total of 1673 patients (age 76±13 years, 68% men) hospitalized for acute heart failure in a tertiary medical center were analyzed. PNI was calculated as 10×serum albumin (g/dL)+0.005×total lymphocyte count (per mm 3 ). National Death Registry was linked to identify the clinical outcomes of all-cause and cardiovascular death. With increasing tertiles of PNI, age and N-terminal probrain natriuretic peptide decreased, and body mass index, estimated glomerular filtration rate, and hemoglobin increased. During a mean follow-up duration of 31.5 months, a higher PNI tertile was related to better survival free from all-cause and cardiovascular mortality in the total study population and in participants with either reduced or preserved left ventricular ejection fraction. After accounting for age, sex, estimated glomerular filtration rate, left ventricular ejection fraction, serum sodium level, and on-admission systolic blood pressure, PNI was independently associated with cardiovascular death and total mortality (hazard ratio per 1 SD of the natural logarithm of the PNI: 0.76 [95% CI, 0.66-0.87] and 0.79 [95% CI, 0.73-0.87], respectively). In subgroup analyses stratified by age, sex, left ventricular ejection fraction, body mass index, or estimated glomerular filtration rate, PNI was consistently related to mortality. PNI is independently associated with long-term survival in patients hospitalized for acute heart failure with either reduced or preserved left ventricular ejection fraction. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
The effects of weight change on glomerular filtration rate.
Chang, Alex; Greene, Tom H; Wang, Xuelei; Kendrick, Cynthia; Kramer, Holly; Wright, Jackson; Astor, Brad; Shafi, Tariq; Toto, Robert; Lewis, Julia; Appel, Lawrence J; Grams, Morgan
2015-11-01
Little is known about the effect of weight loss/gain on kidney function. Analyses are complicated by uncertainty about optimal body surface indexing strategies for measured glomerular filtration rate (mGFR). Using data from the African-American Study of Kidney Disease and Hypertension (AASK), we determined the association of change in weight with three different estimates of change in kidney function: (i) unindexed mGFR estimated by renal clearance of iodine-125-iothalamate, (ii) mGFR indexed to concurrently measured BSA and (iii) GFR estimated from serum creatinine (eGFR). All models were adjusted for baseline weight, time, randomization group and time-varying diuretic use. We also examined whether these relationships were consistent across a number of subgroups, including tertiles of baseline 24-h urine sodium excretion. In 1094 participants followed over an average of 3.6 years, a 5-kg weight gain was associated with a 1.10 mL/min/1.73 m(2) (95% CI: 0.87 to 1.33; P < 0.001) increase in unindexed mGFR. There was no association between weight change and mGFR indexed for concurrent BSA (per 5 kg weight gain, 0.21; 95% CI: -0.02 to 0.44; P = 0.1) or between weight change and eGFR (-0.09; 95% CI: -0.32 to 0.14; P = 0.4). The effect of weight change on unindexed mGFR was less pronounced in individuals with higher baseline sodium excretion (P = 0.08 for interaction). The association between weight change and kidney function varies depending on the method of assessment. Future clinical trials should examine the effect of intentional weight change on measured GFR or filtration markers robust to changes in muscle mass. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Eckfeldt, John H; Karger, Amy B; Miller, W Greg; Rynders, Gregory P; Inker, Lesley A
2015-07-01
Cystatin C is becoming an increasingly popular biomarker for estimating glomerular filtration rate, and accurate measurements of cystatin C concentrations are necessary for accurate estimates of glomerular filtration rate. To assess the accuracy of cystatin C concentration measurements in laboratories participating in the College of American Pathologists CYS Survey. Two fresh frozen serum pools, the first from apparently healthy donors and the second from patients with chronic kidney disease, were prepared and distributed to laboratories participating in the CYS Survey along with the 2 usual processed human plasma samples. Target values were established for each pool by using 2 immunoassays and ERM DA471/IFCC international reference material. For the normal fresh frozen pool (ERM-DA471/IFCC-traceable target of 0.960 mg/L), the all-method mean (SD, % coefficient of variation [CV]) reported by all of the 123 reporting laboratories was 0.894 mg/L (0.128 mg/L, 14.3%). For the chronic kidney disease pool (ERM-DA471/IFCC-traceable target of 2.37 mg/L), the all-method mean (SD, %CV) was 2.258 mg/L (0.288 mg/L, 12.8%). There were substantial method-specific biases (mean milligram per liter reported for the normal pool was 0.780 for Siemens, 0.870 for Gentian, 0.967 for Roche, 1.061 for Diazyme, and 0.970 for other/not specified reagents; and mean milligram per liter reported for the chronic kidney disease pool was 2.052 for Siemens, 2.312 for Gentian, 2.247 for Roche, 2.909 for Diazyme, and 2.413 for other/not specified reagents). Manufacturers need to improve the accuracy of cystatin C measurement procedures if cystatin C is to achieve its full potential as a biomarker for estimating glomerular filtration rate.
The effects of weight change on glomerular filtration rate
Chang, Alex; Greene, Tom H.; Wang, Xuelei; Kendrick, Cynthia; Kramer, Holly; Wright, Jackson; Astor, Brad; Shafi, Tariq; Toto, Robert; Lewis, Julia; Appel, Lawrence J.; Grams, Morgan
2015-01-01
Background Little is known about the effect of weight loss/gain on kidney function. Analyses are complicated by uncertainty about optimal body surface indexing strategies for measured glomerular filtration rate (mGFR). Methods Using data from the African-American Study of Kidney Disease and Hypertension (AASK), we determined the association of change in weight with three different estimates of change in kidney function: (i) unindexed mGFR estimated by renal clearance of iodine-125-iothalamate, (ii) mGFR indexed to concurrently measured BSA and (iii) GFR estimated from serum creatinine (eGFR). All models were adjusted for baseline weight, time, randomization group and time-varying diuretic use. We also examined whether these relationships were consistent across a number of subgroups, including tertiles of baseline 24-h urine sodium excretion. Results In 1094 participants followed over an average of 3.6 years, a 5-kg weight gain was associated with a 1.10 mL/min/1.73 m2 (95% CI: 0.87 to 1.33; P < 0.001) increase in unindexed mGFR. There was no association between weight change and mGFR indexed for concurrent BSA (per 5 kg weight gain, 0.21; 95% CI: −0.02 to 0.44; P = 0.1) or between weight change and eGFR (−0.09; 95% CI: −0.32 to 0.14; P = 0.4). The effect of weight change on unindexed mGFR was less pronounced in individuals with higher baseline sodium excretion (P = 0.08 for interaction). Conclusion The association between weight change and kidney function varies depending on the method of assessment. Future clinical trials should examine the effect of intentional weight change on measured GFR or filtration markers robust to changes in muscle mass. PMID:26085555
Bernstein, J A; Levin, L; Crandall, M S; Perez, A; Lanphear, B
2005-12-01
Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores that are potentially allergenic. The purpose of this pilot study was to investigate whether dehumidification in combination with high-efficiency particulate arrestance (HEPA) filtration is effective at reducing airborne mold spore levels in day care centers. Two day care centers within a 2-mile radius of each other were selected. Day care center A was 2 years old with eight rooms while day care center B was 15 years old with six rooms. A high efficiency Santa Fe dehumidification unit equipped with a HEPA filter was installed in half the rooms (intervention) of each day care facility. Electronic HOBO data loggers continuously measured outdoor and indoor room dew point and temperature every 2 h throughout the study. Dew point and airborne fungal spore measurements from selected rooms with controlled air conditions were analyzed by comparing baseline measurements to those obtained at subsequent time periods over 1 year. Regression models accounted for correlations between measurements in the same room over time. Intervention resulted in a lowered average dew point from baseline by 8.8 degrees C compared with a decrease of 7.1 degrees C in non-intervention rooms across all time periods in both facilities (P<0.001). Fungal analyses demonstrated lower baseline (P=0.06) and follow-up means in intervention rooms (P<0.05), however the change from baseline to end of follow-up differed between intervention and non-intervention rooms in the two facilities. Log transformation was applied to approximate normality of fungal measurements. Dehumidification with HEPA filtration was effective at controlling indoor dew point in both facilities and at reducing airborne culturable fungal spore levels in one of the two facilities. These preliminary results provide a scientific rationale for using this intervention in future studies designed to investigate the impact of indoor mold exposure on health outcomes. Poor indoor air quality is a recognized cause or contributing factor to health effects. Dampness and humidity have been linked to upper and lower respiratory symptoms in children and adults. This study indicates that reducing indoor relative humidity and airborne mold spore levels using high-efficiency dehumidification units equipped with HEPA filtration is feasible even in work facilities such as day care centers where traffic in and out of the building is difficult to regulate. Clinicians should emphasize to their patients the importance of dehumidification and HEPA filtration to improve indoor air quality in the home and workplace.
Carter, Joanne L; Lane, Catherine E; Fan, Stanley L; Lamb, Edmund J
2011-11-01
Measuring glomerular filtration rate (GFR) is an important assessment in peritoneal dialysis patients. In clinical practice, it is commonly measured by calculating the mean of the urinary clearance of urea and creatinine (GFR(UrCl)) but this process is time consuming and unreliable. We wished to compare several estimates of GFR including residual GFR estimated from cystatin C (GFR(CysC)) using a published equation (Hoek), GFR(UrCl) and (51)Cr-ethylenediaminetetraacetic acid (EDTA) clearance, in peritoneal dialysis patients. GFR(CysC), GFR(UrCl) and (51)Cr-EDTA clearance were measured in 28 patients undergoing peritoneal dialysis in a single dialysis unit. GFR(CysC) was related to GFR(UrCl) (Spearman's rank correlation coefficient r(s) = 0.44; P = 0.0185) and to (51)Cr-EDTA clearance (r(s) = 0.48; P = 0.0099). GFR(CysC) values were significantly (P = 0.0077) lower than (51)Cr-EDTA clearance results (mean bias -19.7%). However, GFR(CysC) did not differ significantly (P > 0.05) from GFR(UrCl). GFR(CysC) is related to GFR(UrCl) but has a significant negative bias against (51)Cr-EDTA. Given the known limitations of (51)Cr-EDTA in estimating GFR in renal failure, this study provides additional validation suggesting that cystatin C-estimated rGFR (GFR(CysC)) gives a reasonable estimation of GFR without the clinical problems associated with 24 h urine collections.
Performance evaluation of a dual-flow recharge filter for improving groundwater quality.
Samuel, Manoj P; Senthilvel, S; Mathew, Abraham C
2014-07-01
A dual-flow multimedia stormwater filter integrated with a groundwater recharge system was developed and tested for hydraulic efficiency and pollutant removal efficiency. The influent stormwater first flows horizontally through the circular layers of planted grass and biofibers. Subsequently, the flow direction changes to a vertical direction so that water moves through layers of pebbles and sand and finally gets recharged to the deep aquifers. The media in the sequence of vegetative medium:biofiber to pebble:sand were filled in nine proportions and tested for the best performing combination. Three grass species, viz., Typha (Typha angustifolia), Vetiver (Chrysopogon zizanioides), and St. Augustine grass (Stenotaphrum secundatum), were tested as the best performing vegetative medium. The adsorption behavior of Coconut (Cocos nucifera) fiber, which was filled in the middle layer, was determined by a series of column and batch studies.The dual-flow filter showed an increasing trend in hydraulic efficiency with an increase in flowrate. The chemical removal efficiency of the recharge dual-flow filter was found to be very high in case of K+ (81.6%) and Na+ (77.55%). The pH normalizing efficiency and electrical conductivity reduction efficiency were also recorded as high. The average removal percentage of Ca2+ was moderate, while that of Mg2+ was very low. The filter proportions of 1:1 to 1:2 (plant:fiber to pebble:sand) showed a superior performance compared to all other proportions. Based on the estimated annual costs and returns, all the financial viability criteria (internal rate of return, net present value, and benefit-cost ratio) were found to be favorable and affordable to farmers in terms of investing in the developed filtration system.
2017-04-24
Acute Kidney Injury (AKI); Chronic Kidney Disease (CKD); End Stage Renal Disease (ESRD); Estimated Glomerular Filtration Rate (eGFR); Neutrophil Gelatinase-associated Lipocalin (NGAL); Serum Creatinine (SCr); Urine Creatinine (UCr); Urine Albumin (UAlb)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erdman, M.D.; Reddy, C.A.
1986-03-01
An optimized batch fermentation process for the conversion of cattle feedlot waste filtrate, supplemented with cheese whey, into a nitrogenous feed supplement for ruminants is described. Feedlot waste filtrate supplemented with cheese whey (5 g of whey per 100 ml) was fermented by the indigenous microbial flora in the feedlot waste filtrate. Ammonium hydroxide was added to the fermentation not only to maintain a constant pH but also to produce ammonium salts of organic acids, which have been shown to be valuable as nitrogenous feed supplements for ruminants. The utilization of substrate carbohydrate at pH 7.0 and 43 degrees Cmore » was greater than 94% within 8 h, and the crude protein (total N X 6.25) content of the product was 70 to 78% (dry weight basis). About 66 to 69% of the crude protein was in the form of ammonia nitrogen. Lactate and acetate were the predominant acids during the first 6 to 8 hours of fermentation, but after 24 hours, appreciable levels of propionate and butyrate were also present. The rate of fermentation and the crude protein content of the product were optimal at pH 7.0 and decreased at a lower pH. For example, fermentation did not go to completion even after 24 hours at pH 4.5. Fermentation proceeded optimally at 43 degrees C, less so at 37 degrees C, and considerably more slowly at 23 and 50 degrees C. Concentrations of up to 15 g of cheese whey per 100 ml of feedlot waste filtrate were fermented efficiently. Fermentation of feedlot waste filtrate obtained from animals fed low silage-high grain, high silage-low grain, or dairy rations resulted in similar products in terms of total nitrogen and organic acid composition.« less
Olson, D.W.
2000-01-01
The state of the global industrial garnet industry in 1999 is discussed. Industrial garnet mined in the U.S., which accounts for approximately one-third of the world's total, is usually a solid-solution of almandine and pyrope. The U.S. is the largest consumer of industrial garnet, using an estimated 47,800 st in 1999 as an abrasive and as a filtration medium in the petroleum industry, filtration plants, aircraft and motor vehicle manufacture, shipbuilding, wood furniture finishing operations, electronic component manufacture, ceramics manufacture, and glass production. Prices for crude concentrates ranged from approximately $50 to $110/st and refined garnet from $50 to $215/st in 1999, depending on type, source, quantity purchased, quality, and application.
Takagi, Toshio; Kondo, Tsunenori; Tachibana, Hidekazu; Iizuka, Junpei; Omae, Kenji; Kobayashi, Hirohito; Yoshida, Kazuhiko; Tanabe, Kazunari
2017-07-01
To compare surgical outcomes between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy in patients with chronic kidney disease. Of 550 patients who underwent partial nephrectomy between 2012 and 2015, 163 patients with T1-2 renal tumors who had an estimated glomerular filtration rate between 30 and 60 mL/min/1.73 m 2 , and underwent robot-assisted laparoscopic partial nephrectomy or open partial nephrectomy were retrospectively analyzed. To minimize selection bias between the two surgical methods, patient variables were adjusted by 1:1 propensity score matching. The present study included 75 patients undergoing robot-assisted laparoscopic partial nephrectomy and 88 undergoing open partial nephrectomy. After propensity score matching, 40 patients were included in each operative group. The mean preoperative estimated glomerular filtration rate was 49 mL/min/1.73 m 2 . The mean ischemia time was 21 min in robot-assisted laparoscopic partial nephrectomy (warm ischemia) and 35 min in open partial nephrectomy (cold ischemia). Preservation of the estimated glomerular filtration rate 3-6 months postoperatively was not significantly different between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy (92% vs 91%, P = 0.9348). Estimated blood loss was significantly lower in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (104 vs 185 mL, P = 0.0025). The postoperative length of hospital stay was shorter in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (P < 0.0001). The prevalence of Clavien-Dindo grade 3 complications and a negative surgical margin status were not significantly different between the two groups. In our experience, robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy provide similar outcomes in terms of functional preservation and perioperative complications among patients with chronic kidney disease. However, a lower estimated blood loss and shorter postoperative length of hospital stay can be obtained with robot-assisted laparoscopic partial nephrectomy. © 2017 The Japanese Urological Association.
Method for reducing pressure drop through filters, and filter exhibiting reduced pressure drop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sappok, Alexander; Wong, Victor
Methods for generating and applying coatings to filters with porous material in order to reduce large pressure drop increases as material accumulates in a filter, as well as the filter exhibiting reduced and/or more uniform pressure drop. The filter can be a diesel particulate trap for removing particulate matter such as soot from the exhaust of a diesel engine. Porous material such as ash is loaded on the surface of the substrate or filter walls, such as by coating, depositing, distributing or layering the porous material along the channel walls of the filter in an amount effective for minimizing ormore » preventing depth filtration during use of the filter. Efficient filtration at acceptable flow rates is achieved.« less
[Construction and application of an onboard absorption analyzer device for CDOM].
Lin, Jun-Fang; Sun, Zhao-Hua; Cao, Wen-Xi; Hu, Shui-Bo; Xu, Zhan-Tang
2013-04-01
Colored dissolved organic matter (CDOM) plays an important role in marine ecosystems. In order to solve the current problems in measurement of CDOM absorption, an automated onboard analyzer based on liquid core waveguides (Teflon AF LWCC/LCW) was constructed. This analyzer has remarkable characteristics including adjusted optical pathlength, wide measurement range, and high sensitivity. The model of filtration and injection can implement the function of automated filtration, sample injection, and LWCC cleaning. The LabVIEW software platform can efficiently control the running state of the analyzer and acquire real time data including light absorption spectra, GPS data, and CTW data. By the comparison experiments and shipboard measurements, it was proved that the analyzer was reliable and robust.
Sakamoto, Masashi; Hashimoto, Ryuya; Yoshida, Izumi; Maeno, Takatoshi
2018-01-01
We retrospectively reviewed patients with postoperative neovascular glaucoma (NVG) after vitrectomy for proliferative diabetic retinopathy to investigate how variables assessed before, during, and after vitrectomy are associated with the requirement for filtration surgery. The subjects in this retrospective, observational, comparative study were 55 consecutive patients (61 eyes) who underwent vitrectomy for proliferative diabetic retinopathy at Toho University Sakura Medical Center between December 2011 and November 2016, were followed up for at least 6 months after surgery, and developed NVG within 2 years after surgery. They comprised 44 men and 11 women of mean age 52.4±9.1 years, who were followed up for a mean 7.1±6.1 months. We collected data on the following 16 variables: sex, age, history of panretinal photocoagulation completed within 3 months before vitrectomy, presence/absence of a lens, obvious iris/angle neovascularization, tractional retinal detachment, diabetic macular edema, vitreous hemorrhage, visual acuity and intraocular pressure before vitrectomy and at the onset of NVG, glycated hemoglobin, fasting blood glucose, estimated glomerular filtration rate, and use of intraoperative gas tamponade. Logistic regression analysis with the backward elimination method identified preoperative fasting hyperglycemia ( P =0.08), high intraocular pressure at the onset of NVG ( P =0.04), and use of gas tamponade during vitrectomy ( P =0.008) to be significant risk factors for requirement of filtration surgery. Preoperative fasting hyperglycemia, high intraocular pressure at the onset of NVG, and use of gas tamponade during vitrectomy predispose patients to require filtration surgery in the event of postoperative NVG.
NASA Astrophysics Data System (ADS)
Trinh Nguyen, Thuy Ai; Phu Dang, Van; Duy Nguyen, Ngoc; Le, Anh Quoc; Thanh Nguyen, Duc; Hien Nguyen, Quoc
2014-09-01
Porous ceramic candle filters (PCCF) were prepared by sintering silica from rice husk with silver nanoparticles (AgNPs)/zeolite A at about 1050 °C to create bactericidal PCCF/AgNPs for water disinfection. The silver content in PCCF/AgNPs was of 300-350 mg kg-1 determined by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) and the average pore size of PCCF/AgNPs was of 50-70 Å measured by Brunauer-Emmett-Teller (BET) method. The bactericidal activity and silver release of PCCF/AgNPs have been investigated by flow test with water flow rate of 5 L h-1 and initial inoculation of E. coli in inlet water of 106 CFU/100 mL. The volume of filtrated water was collected up to 500 L. Results showed that the contamination of E. coli in filtrated water was <1 CFU/100 mL and the content of silver released from PCCF/AgNPs into filtrated water was <1 μg L-1, it is low, far under the WHO guideline of 100 μg L-1 at maximum for drinking water. Based on the content of silver in PCCF/AgNPs and in filtrated water, it was estimated that one PCCF/AgNPs could be used to filtrate of ˜100 m3 water. Thus, as-prepared PCCF/AgNPs releases low content of silver into water and shows effectively bactericidal activity that is promising to apply as point-of-use water treatment technology for drinking water disinfection.
Tofts, Paul S; Cutajar, Marica; Mendichovszky, Iosif A; Peters, A Michael; Gordon, Isky
2012-06-01
To model the uptake phase of T(1)-weighted DCE-MRI data in normal kidneys and to demonstrate that the fitted physiological parameters correlate with published normal values. The model incorporates delay and broadening of the arterial vascular peak as it appears in the capillary bed, two distinct compartments for renal intravascular and extravascular Gd tracer, and uses a small-vessel haematocrit value of 24%. Four physiological parameters can be estimated: regional filtration K ( trans ) (ml min(-1) [ml tissue](-1)), perfusion F (ml min(-1) [100 ml tissue](-1)), blood volume v ( b ) (%) and mean residence time MRT (s). From these are found the filtration fraction (FF; %) and total GFR (ml min(-1)). Fifteen healthy volunteers were imaged twice using oblique coronal slices every 2.5 s to determine the reproducibility. Using parenchymal ROIs, group mean values for renal biomarkers all agreed with published values: K ( trans ): 0.25; F: 219; v ( b ): 34; MRT: 5.5; FF: 15; GFR: 115. Nominally cortical ROIs consistently underestimated total filtration (by ~50%). Reproducibility was 7-18%. Sensitivity analysis showed that these fitted parameters are most vulnerable to errors in the fixed parameters kidney T(1), flip angle, haematocrit and relaxivity. These renal biomarkers can potentially measure renal physiology in diagnosis and treatment. • Dynamic contrast-enhanced magnetic resonance imaging can measure renal function. • Filtration and perfusion values in healthy volunteers agree with published normal values. • Precision measured in healthy volunteers is between 7 and 15%.
Treatment and potential reuse of greywater from schools: a pilot study.
Alsulaili, Abdalrahman D; Hamoda, Mohamed F; Al-Jarallah, Rawa; Alrukaibi, Duaij
2017-05-01
This study presented performance data on a low cost and easy maintenance pilot system for on-site treatment and reuse of water collected from wash sinks and fountains, as major sources of greywater (GW) at schools. Various treatment options were studied including screening, sand filtration, chlorination, and UV disinfection operated at different flow rates. Results showed that filtration operated at low rates is very effective in total suspended solids (TSS) removal, while UV proved to be more effective than chlorination for reduction of biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total coliforms. Removal efficiencies up to 63%, 30% and 20% were obtained for TSS, COD and BOD, respectively and reductions of log TC (CFU/100 ml) from 6.5 to 2 were obtained at a filtration rate of 14 m 3 /d·m 2 . Treated effluent satisfied WHO standards for reclaimed water reuse in landscape irrigation and toilet flushing. The filtration-UV system is robust, showing the best and most reliable performance for low and high strength GW treatment even under a 10-fold increase in flow rate. A 5 m 3 /d pilot plant was developed for schools having 500 students and detailed cost-benefit analysis indicated a net saving value, a surplus of $1,600 per year, and pay back after 6 years and 11 months.
Grünheid, Steffen; Amy, Gary; Jekel, Martin
2005-09-01
Bank filtration and artificial recharge provide an important drinking water source to the city of Berlin. Due to the practice of water recycling through a semi-closed urban water cycle, the introduction of effluent organic matter (EfOM) and persistent trace organic pollutants in the drinking water is of potential concern. In the work reported herein, the research objectives are to study the removal of bulk and trace organics at bank filtration and artificial recharge sites and to assess important factors of influence for the Berlin area. The monthly analytical program is comprised of dissolved organic carbon (DOC), UV absorbance (UVA254), liquid chromatography with organic carbon detection (LC-OCD), differentiated adsorbable organic halogens (AOX) and single organic compound analysis of a few model compounds. More than 1 year of monitoring was conducted on observation wells located along the flowpaths of the infiltrating water at two field sites that have different characteristics regarding redox conditions, travel time, and travel distance. Two transects are highlighted: one associated with a bank filtration site dominated by anoxic/anaerobic conditions with a travel time of up to 4-5 months, and another with an artificial recharge site dominated by aerobic conditions with a travel time of up to 50 days. It was found that redox conditions and travel time significantly influence the DOC degradation kinetics and the efficiency of AOX and trace compound removal.
Flood induced infiltration affecting a bank filtrate well at the River Enns, Austria
NASA Astrophysics Data System (ADS)
Wett, Bernhard; Jarosch, Hannes; Ingerle, Kurt
2002-09-01
Bank filtration employs a natural filtration process of surface water on its flow path from the river to the well. The development of a stable filter layer is of major importance to the quality of the delivered water. Flooding is expected to destabilise the riverbed, to reduce the filter efficiency of the bank and therefore to endanger the operation of water supply facilities near the riverbank. This paper provides an example of how bank storage in an unconfined alluvial aquifer causes a significant decrease of the seepage rate after a high-water event. Extensive monitoring equipment has been installed in the river bank of the oligotrophic alpine River Enns focusing on the first metre of the flow path. Head losses measured by multilevel probes throughout a year characterise the development of the hydraulic conductivity of different riverbed layers. Concentration profiles of nitrate, total ions and a NaCl tracer have been used to study infiltration rates of river water and its dilution with groundwater. Dynamic modelling was applied in order to investigate the propagation of flood induced head elevation and transport of pollutants.
CRADA opportunities in removal of particulates from hot-gas streams by filtration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, D H
1995-06-01
Our analyses of samples and operating data from the Pressurized Fluidized Bed Combustion (PFBC), cyclone, and filtration units of the Tidd Clean Coal demonstration facility show that calcined dolomitic sorbent reacted with SO{sub 2} (and O{sub 2}) to form Sulfates (CaSO{sub 4} and CaMgn [SO{sub 4}]n+1) not only in the PFBC bed, but also in the filtration vessel. Analyses of limited data from the journal literature suggest that the filter-vessel reactions may have produced sulfate {open_quotes}necks,{close_quotes} which bonded the particles together, thus substantially increasing the critical angle of repose and shear tensile strengths of the filtered powders. This proposed mechanismmore » rationalizes the {open_quotes}bridging{close_quotes} and other particle-accumulation problems that caused filter breakage. Engineering services potentially available to resolve these problems include elucidation and modeling of ex-situ and in-situ filter-vessel chemistry, measurement and modeling of particulate materials properties, and measurement and modeling of cleaning back-pulse aerodynamics and cleaning efficiencies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
James K. Neathery; Gary Jacobs; Burtron H. Davis
In this reporting period, a fundamental filtration study was started to investigate the separation of Fischer-Tropsch Synthesis (FTS) liquids from iron-based catalyst particles. Slurry-phase FTS in slurry bubble column reactor systems is the preferred mode of production since the reaction is highly exothermic. Consequently, heavy wax products must be separated from catalyst particles before being removed from the reactor system. Achieving an efficient wax product separation from iron-based catalysts is one of the most challenging technical problems associated with slurry-phase FTS. The separation problem is further compounded by catalyst particle attrition and the formation of ultra-fine iron carbide and/or carbonmore » particles. Existing pilot-scale equipment was modified to include a filtration test apparatus. After undergoing an extensive plant shakedown period, filtration tests with cross-flow filter modules using simulant FTS wax slurry were conducted. The focus of these early tests was to find adequate mixtures of polyethylene wax to simulate FTS wax. Catalyst particle size analysis techniques were also developed. Initial analyses of the slurry and filter permeate particles will be used by the research team to design improved filter media and cleaning strategies.« less
Applicability of dynamic membrane technology in anaerobic membrane bioreactors.
Ersahin, Mustafa Evren; Ozgun, Hale; Tao, Yu; van Lier, Jules B
2014-01-01
This study investigated the applicability of dynamic membrane technology in anaerobic membrane bioreactors for the treatment of high strength wastewaters. A monofilament woven fabric was used as support material for dynamic membrane formation. An anaerobic dynamic membrane bioreactor (AnDMBR) was operated under a variety of operational conditions, including different sludge retention times (SRTs) of 20 and 40 days in order to determine the effect of SRT on both biological performance and dynamic membrane filtration characteristics. High COD removal efficiencies exceeding 99% were achieved during the operation at both SRTs. Higher filtration resistances were measured during the operation at SRT of 40 days in comparison to SRT of 20 days, applying a stable flux of 2.6 L/m(2) h. The higher filtration resistances coincided with lower extracellular polymeric substances concentration in the bulk sludge at SRT of 40 days, likely resulting in a decreased particle flocculation. Results showed that dynamic membrane technology achieved a stable and high quality permeate and AnDMBRs can be used as a reliable and satisfactory technology for treatment of high strength wastewaters. Copyright © 2013 Elsevier Ltd. All rights reserved.
Zhang, Xiang; Ma, Jun; Lu, Xixin; Huangfu, Xiaoliu; Zou, Jing
2015-12-30
Comparatively investigated the different effects of Fe2(SO4)3 coagulation-filtration and FeCl3 coagulation-filtration on the removal of Mo (VI). And the influence of calcium, sulfate, silicate, phosphate and humic acid (HA) were also studied. The following conclusions can be obtained: (1) compared with the case of FeCl3, Fe2(SO4)3 showed a higher Mo (VI) removal efficiency at pH 4.00-5.00, but an equal removal efficiency at pH 6.00-9.00. (2) The optimum Mo (VI) removal by Fe2(SO4)3 was achieved at pH 5.00-6.00; (3) The presence of calcium can reduce the removal of Mo (VI) over the entire pH range in the present study; (4) The effect of co-existing background anions (including HA) was dominated by three factors: Firstly the influence of co-existing background anions on the content of Fe intercepted from water (intercepted Fe). Secondly the competition of co-existing anions with Mo (VI) for adsorption sites. Thirdly the influence of co-existing background anions on the Zeta potential of the iron flocs. Copyright © 2015 Elsevier B.V. All rights reserved.
Amphiphobic Polytetrafluoroethylene Membranes for Efficient Organic Aerosol Removal.
Feng, Shasha; Zhong, Zhaoxiang; Zhang, Feng; Wang, Yong; Xing, Weihong
2016-04-06
Polytetrafluoroethylene (PTFE) membrane is an extensively used air filter, but its oleophilicity leads to severe fouling of the membrane surface due to organic aerosol deposition. Herein, we report the fabrication of a new amphiphobic 1H,1H,2H,2H-perfluorodecyl acrylate (PFDAE)-grafted ZnO@PTFE membrane with enhanced antifouling functionality and high removal efficiency. We use atomic-layer deposition (ALD) to uniformly coat a layer of nanosized ZnO particles onto porous PTFE matrix to increase surface area and then subsequently graft PFDAE with plasma. Consequently, the membrane surface showed both superhydrophobicity and oleophobicity with a water contact angle (WCA) and an oil contact angle (OCA) of 150° and 125°, respectively. The membrane air permeation rate of 513 (m(3) m(-2) h(-1) kPa(-1)) was lower than the pristine membrane rate of 550 (m(3) m(-2) h(-1) kPa(-1)), which indicates the surface modification slightly decreased the membrane air permeation. Significantly, the filtration resistance of this amphiphobic membrane to the oil aerosol system was much lower than the initial one. Moreover, the filter exhibited exceptional organic aerosol removal efficiencies that were greater than 99.5%. These results make the amphiphobic PTFE membranes very promising for organic aerosol-laden air-filtration applications.
Waste Water Management and Infectious Disease. Part II: Impact of Waste Water Treatment
ERIC Educational Resources Information Center
Cooper, Robert C.
1975-01-01
The ability of various treatment processes, such as oxidation ponds, chemical coagulation and filtration, and the soil mantle, to remove the agents of infectious disease found in waste water is discussed. The literature concerning the efficiency of removal of these organisms by various treatment processes is reviewed. (BT)
Aligned Carbon Nanotubes for Highly Efficient Energy Generation and Storage Devices
2012-01-24
solution processing methods, including filtration, solution-casting, electrophoretic deposition, and Langmuir - Blodgett deposition. However, most...supercapacitors with environmentally friendly ionic liquid electrolytes. These new nanocomposite electrodes consist of the high-surface-area activated...carbons, carbon nanotubes, and ionic liquids as the integrated constituent components. The resultant composites show significantly improved charge
The Environmental Technology Verification report discusses the technology and performance of the High Efficiency Mini Pleat air filter for dust and bioaerosol filtration manufactured by Columbus Industries. The pressure drop across the filter was 142 Pa clean and 283 Pa dust load...
Buyel, Johannes F.; Gruchow, Hannah M.; Fischer, Rainer
2015-01-01
The clarification of biological feed stocks during the production of biopharmaceutical proteins is challenging when large quantities of particles must be removed, e.g., when processing crude plant extracts. Single-use depth filters are often preferred for clarification because they are simple to integrate and have a good safety profile. However, the combination of filter layers must be optimized in terms of nominal retention ratings to account for the unique particle size distribution in each feed stock. We have recently shown that predictive models can facilitate filter screening and the selection of appropriate filter layers. Here we expand our previous study by testing several filters with different retention ratings. The filters typically contain diatomite to facilitate the removal of fine particles. However, diatomite can interfere with the recovery of large biopharmaceutical molecules such as virus-like particles and aggregated proteins. Therefore, we also tested filtration devices composed solely of cellulose fibers and cohesive resin. The capacities of both filter types varied from 10 to 50 L m−2 when challenged with tobacco leaf extracts, but the filtrate turbidity was ~500-fold lower (~3.5 NTU) when diatomite filters were used. We also tested pre–coat filtration with dispersed diatomite, which achieved capacities of up to 120 L m−2 with turbidities of ~100 NTU using bulk plant extracts, and in contrast to the other depth filters did not require an upstream bag filter. Single pre-coat filtration devices can thus replace combinations of bag and depth filters to simplify the processing of plant extracts, potentially saving on time, labor and consumables. The protein concentrations of TSP, DsRed and antibody 2G12 were not affected by pre-coat filtration, indicating its general applicability during the manufacture of plant-derived biopharmaceutical proteins. PMID:26734037
2013-01-01
Background Exposure to particulate air pollution increases respiratory and cardiovascular morbidity and mortality, especially in elderly, possibly through inflammation and vascular dysfunction. Methods We examined potential beneficial effects of indoor air filtration in the homes of elderly, including people taking vasoactive drugs. Forty-eight nonsmoking subjects (51 to 81 years) in 27 homes were included in this randomized, double-blind, crossover intervention study with consecutive two-week periods with or without the inclusion of a high-efficiency particle air filter in re-circulating custom built units in their living room and bedroom. We measured blood pressure, microvascular and lung function and collected blood samples for hematological, inflammation, monocyte surface and lung cell damage markers before and at day 2, 7 and 14 during each exposure scenario. Results The particle filters reduced the median concentration of PM2.5 from approximately 8 to 4 μg/m3 and the particle number concentration from 7669 to 5352 particles/cm3. No statistically significant effects of filtration as category were observed on microvascular and lung function or the biomarkers of systemic inflammation among all subjects, or in the subgroups taking (n = 11) or not taking vasoactive drugs (n = 37). However, the filtration efficacy was variable and microvascular function was within 2 days significantly increased with the actual PM2.5 decrease in the bedroom, especially among 25 subjects not taking any drugs. Conclusion Substantial exposure contrasts in the bedroom and no confounding by drugs appear required for improved microvascular function by air filtration, whereas no other beneficial effect was found in this elderly population. PMID:24373585
Buyel, Johannes F; Gruchow, Hannah M; Fischer, Rainer
2015-01-01
The clarification of biological feed stocks during the production of biopharmaceutical proteins is challenging when large quantities of particles must be removed, e.g., when processing crude plant extracts. Single-use depth filters are often preferred for clarification because they are simple to integrate and have a good safety profile. However, the combination of filter layers must be optimized in terms of nominal retention ratings to account for the unique particle size distribution in each feed stock. We have recently shown that predictive models can facilitate filter screening and the selection of appropriate filter layers. Here we expand our previous study by testing several filters with different retention ratings. The filters typically contain diatomite to facilitate the removal of fine particles. However, diatomite can interfere with the recovery of large biopharmaceutical molecules such as virus-like particles and aggregated proteins. Therefore, we also tested filtration devices composed solely of cellulose fibers and cohesive resin. The capacities of both filter types varied from 10 to 50 L m(-2) when challenged with tobacco leaf extracts, but the filtrate turbidity was ~500-fold lower (~3.5 NTU) when diatomite filters were used. We also tested pre-coat filtration with dispersed diatomite, which achieved capacities of up to 120 L m(-2) with turbidities of ~100 NTU using bulk plant extracts, and in contrast to the other depth filters did not require an upstream bag filter. Single pre-coat filtration devices can thus replace combinations of bag and depth filters to simplify the processing of plant extracts, potentially saving on time, labor and consumables. The protein concentrations of TSP, DsRed and antibody 2G12 were not affected by pre-coat filtration, indicating its general applicability during the manufacture of plant-derived biopharmaceutical proteins.
Therapeutic apheresis for severe hypertriglyceridemia in pregnancy.
Basar, Rafet; Uzum, Ayse Kubat; Canbaz, Bulent; Dogansen, Sema Ciftci; Kalayoglu-Besisik, Sevgi; Altay-Dadin, Senem; Aral, Ferihan; Ozbey, Nese Colak
2013-05-01
During pregnancy, a progressive increase in serum triglyceride (TG) and cholesterol levels is observed whereas TG levels mostly remain <300 mg/dl. In women with genetic forms of hypertriglyceridemia, pregnancy may cause extremely elevated TG levels leading to potentially life-threatening pancreatitis attacks and chylomicronemia syndrome. The only safe medical treatment option during pregnancy is ω-3 fatty acids, which have moderate TG lowering effects. Therapeutic apheresis could be used as primary treatment approach during pregnancy. We reported the effect of double filtration apheresis in one pregnant women with severe hypertriglyceridemia, therapeutic plasmapheresis and double filtration methods in the other severe hypertriglyceridemic pregnant woman; a 32-year-old pregnant woman (patient 1) with a history of hypertriglyceridemia-induced acute pancreatitis during pregnancy and a 30-year-old pregnant woman with extremely high TG levels (12,000 mg/dl) leading to chylomicronemia syndrome (patient 2). Medical nutrition therapy and ω-3 fatty acids were also provided. Double filtration apheresis (patient 1) and plasmapheresis + double filtration apheresis (patient 2) were used. When we calculated the TG levels before and after therapeutic apheresis, maximum decrease achieved with double filtration apheresis was 46.3 % for patient 1 and 37.3 % for patient 2. However, with plasmapheresis TG level declined by 72 % in patient 2. Plasmapheresis seemed to be more efficient to decrease TG levels. Iron deficiency anemia was the main complication apart from technical difficulties by lipemic obstruction of tubing system. Healthy babies were born. Delivery led to decreases in TG levels. It is concluded that during pregnancy therapeutic apheresis is an effective method to decrease extremely high TG levels and risks of its potentially life-threatening complications.
Devarajan, Nainamalai; Karthik, Murugan; Suresh, Palaniswamy
2017-11-07
A straightforward and efficient method has been demonstrated for the oxidative coupling of terminal alkynes using a simple Cu 3 (BTC) 2 -metal organic framework as a sustainable heterogeneous copper catalyst. A series of symmetrical 1,3-diynes bearing diverse functional groups have been synthesized in moderate to excellent yields via a Cu 3 (BTC) 2 catalyzed Glaser-Hay reaction. The presence of the coordinatively unsaturated open Cu II sites in Cu 3 (BTC) 2 catalyzes the homocoupling in the presence of air, as an environment friendly oxidant without the use of external oxidants, ligands or any additives. The present methodology avoids stoichiometric reagents and harsher or special reaction conditions, and shows good functional group tolerance. The as-prepared catalyst could be separated easily by simple filtration and reused several times without any notable loss in activity. The hot filtration test has investigated the true heterogeneity of the catalyst. Additionally, the powder X-ray diffraction pattern of the reused catalyst revealed the high stability of the catalyst.
Ding, An; Liang, Heng; Qu, Fangshu; Bai, Langming; Li, Guibai; Ngo, Huu Hao; Guo, Wenshan
2014-11-01
To mitigate membrane fouling of membrane-coupled anaerobic process, granular activated carbon (GAC: 50 g/L) was added into an expanded granular sludge bed (EGSB). A short-term ultrafiltration test was investigated for analyzing membrane fouling potential and underlying fouling mechanisms. The results showed that adding GAC into the EGSB not only improved the COD removal efficiency, but also alleviated membrane fouling efficiently because GAC could help to reduce soluble microbial products, polysaccharides and proteins by 26.8%, 27.8% and 24.7%, respectively, compared with the control system. Furthermore, excitation emission matrix (EEM) fluorescence spectroscopy analysis revealed that GAC addition mainly reduced tryptophan protein-like, aromatic protein-like and fulvic-like substances. In addition, the resistance distribution analysis demonstrated that adding GAC primarily decreased the cake layer resistance by 53.5%. The classic filtration mode analysis showed that cake filtration was the major fouling mechanism for membrane-coupled EGSB process regardless of the GAC addition. Copyright © 2014 Elsevier Ltd. All rights reserved.
Boleda, M A Rosa; Galceran, M A Teresa; Ventura, Francesc
2011-06-01
The behavior along the potabilization process of 29 pharmaceuticals and 12 drugs of abuse identified from a total of 81 compounds at the intake of a drinking water treatment plant (DWTP) has been studied. The DWTP has a common treatment consisting of dioxychlorination, coagulation/flocculation and sand filtration and then water is splitted in two parallel treatment lines: conventional (ozonation and carbon filtration) and advanced (ultrafiltration and reverse osmosis) to be further blended, chlorinated and distributed. Full removals were reached for most of the compounds. Iopromide (up to 17.2 ng/L), nicotine (13.7 ng/L), benzoylecgonine (1.9 ng/L), cotinine (3.6 ng/L), acetaminophen (15.6 ng/L), erythromycin (2.0 ng/L) and caffeine (6.0 ng/L) with elimination efficiencies ≥ 94%, were the sole compounds found in the treated water. The advanced treatment process showed a slightly better efficiency than the conventional treatment to eliminate pharmaceuticals and drugs of abuse. Copyright © 2011 Elsevier Ltd. All rights reserved.
Leion, Felicia; Hegbrant, Josefine; den Bakker, Emil; Jonsson, Magnus; Abrahamson, Magnus; Nyman, Ulf; Björk, Jonas; Lindström, Veronica; Larsson, Anders; Bökenkamp, Arend; Grubb, Anders
2017-09-01
Estimating glomerular filtration rate (GFR) in adults by using the average of values obtained by a cystatin C- (eGFR cystatin C ) and a creatinine-based (eGFR creatinine ) equation shows at least the same diagnostic performance as GFR estimates obtained by equations using only one of these analytes or by complex equations using both analytes. Comparison of eGFR cystatin C and eGFR creatinine plays a pivotal role in the diagnosis of Shrunken Pore Syndrome, where low eGFR cystatin C compared to eGFR creatinine has been associated with higher mortality in adults. The present study was undertaken to elucidate if this concept can also be applied in children. Using iohexol and inulin clearance as gold standard in 702 children, we studied the diagnostic performance of 10 creatinine-based, 5 cystatin C-based and 3 combined cystatin C-creatinine eGFR equations and compared them to the result of the average of 9 pairs of a eGFR cystatin C and a eGFR creatinine estimate. While creatinine-based GFR estimations are unsuitable in children unless calibrated in a pediatric or mixed pediatric-adult population, cystatin C-based estimations in general performed well in children. The average of a suitable creatinine-based and a cystatin C-based equation generally displayed a better diagnostic performance than estimates obtained by equations using only one of these analytes or by complex equations using both analytes. Comparing eGFR cystatin and eGFR creatinine may help identify pediatric patients with Shrunken Pore Syndrome.
Vogel, J.R.; Barber, L.B.; Furlong, E.T.; Coplen, T.B.; Verstraeten, Ingrid M.; Meyer, M.T.
2005-01-01
This document is the second volume of a data series report that describes the data collected during a study conducted during 2001 through 2005 by the U.S. Geological Survey, in cooperation with the U.S. Environmental Protection Agency and the City of Lincoln, at an established riverbank-filtration well field with horizontal collector wells and vertical wells. The data were collected as part of a study designed to help researchers better understand the efficiency of riverbank filtration with respect to endocrine disrupting compounds and to evaluate the use of riverbank filtration as an effective means of drinking-water treatment. This study provides information that will be useful for (1) increased understanding of the processes and factors controlling the transport of endocrine disrupters, such as pesticides and pharmaceuticals during riverbank filtration, (2) better understanding of the physical and chemical processes that affect riverbank-filtration efficiency, and (3) managing the water resources of the eastern Platte River Basin. This report presents analytical methods and additional data for pharmaceuticals, dissolved organic carbon (DOC), ultraviolet absorbance at 254 nanometer (nm) wavelength (UV254), specific ultraviolet absorbance (SUVA), nitrilotriacetic acid (NTA), ethylenediaminetetraacetic acid (EDTA), nonylphenol ethoxycarboxylates (NPECs), and stable hydrogen and oxygen isotope ratios that were not available at the time of publication of Volume 1 in the data series. Data are presented as generalized statistics and in figures showing temporal variations. Sites from which water-quality samples were collected for this study included wastewater sites (a cattle feedlot lagoon, a hog confinement lagoon, and wastewater-treatment plant effluent), surface-water sites (Platte River, Salt Creek, and Loup Power Canal), ground-water sites (one collector well and five vertical wells), and drinking-water sites (raw and finished). Field water-quality properties also were measured in samples from these sites. Pharmaceuticals detected at least once in samples collected from the Platte River included 1,7-dimethylxanthine, acetaminophen, caffeine, carbamazapine, and cotinine. Among the ground-water samples, pharmaceutical compounds detected at low concentrations in at least one sample included 1,7-dimethylxanthine, acetaminophen, carbamazapine, and trimethoprim. When analyzing for non-pharmaceutical compounds in samples from the wastewater sites, the wastewater-treatment plant effluent samples had the highest concentrations of each of NTA, EDTA, and NPECs compounds. Surface-water samples from Salt Creek had higher concentrations of EDTA and NPECs than samples from the Platte River. NTA was not detected in any samples from the ground-water sites. EDTA was detected in all samples from all wells. Detectable concentrations of EDTA were also observed in all samples from the raw water and finished water.
Baskaran, M.; Swarzenski, P.W.; Biddanda, B.A.
2009-01-01
[1] Large volume (102-103 L) seawater samples are routinely processed to investigate the partitioning of particle reactive radionuclides and Ra between solution and size-fractionated suspended particulate matter. One of the most frequently used methods to preconcentrate these nuclides from such large volumes involves extraction onto three filter cartridges (a prefilter for particulate species and two MnO2-coated filters for dissolved species) connected in series. This method assumes that the extraction efficiency is uniform for both MnO2-coated cartridges, that no dissolved species are removed by the prefilter, and that any adsorbed radionuclides are not desorbed from the MnO2-coated cartridges during filtration. In this study, we utilized 234Th-spiked coastal seawater and deionized water to address the removal of dissolved Th onto prefilters and MnO2-coated filter cartridges. Experimental results provide the first data that indicate (1) a small fraction of dissolved Th (<6%) can be removed by the prefilter cartridge; (2) a small fraction of dissolved Th (<5%) retained by the MnO2 surface can also be desorbed, which undermines the assumption of uniform extraction efficiency for Th; and (3) the absolute and relative extraction efficiencies can vary widely. These experiments provide insight on the variability of the extraction efficiency of MnO 2-coated filter cartridges by comparing the relative and absolute efficiencies and recommend the use of a constant efficiency on the combined activity from two filter cartridges connected in series for future studies of dissolved 234Th and other radionuclides in natural waters using sequential filtration/extraction methods. ?? 2009 by the American Geophysical Union.
Nehring, R Barry; Thompson, Kevin G; Taurman, Karen; Atkinson, William
2003-12-03
The aquatic oligochaete Tubifex tubifex parasitized by Myxobolus cerebralis releases triactinomyxon (TAM) actinospores that can infect some species of salmonids and cause salmonid whirling disease. Silica sand was tested as a filtration medium for removal of TAMs from water containing the parasite. Laboratory tests indicated sand filtration removed > 99.99% of TAMs. In 2 different field tests, groups of 1 mo old rainbow trout Oncorhynchus mykiss were exposed for 2 wk to filtered and unfiltered water from a spring-fed pond enzootic for M. cerebralis. In November 2000, the exposure dose was estimated as between 3 and 5 TAMs fish(-1). During a March 2001 exposure, the estimated dose was between 286 and 404 TAMs fish(-1). Fish were held for 6 mo post exposure (p.e.) in laboratory aquaria for observation and evidence of clinical signs of whirling disease. We used 4 diagnostic techniques to assess the prevalence and severity of infection by M. cerebralis among fish exposed to filtered and unfiltered water. These included polymerase chain reaction (PCR) for genomic DNA of the parasite, histological evaluation for tissue damage, tissue digestion for quantification of cranial myxospores of the parasite, and total non-sampling mortality that occurred over 6 mo p.e. All diagnostic tests verified that the prevalence and severity of infection was significantly reduced among fish in treatment groups exposed to filtered water compared to those exposed to unfiltered water in both the low-dose and high-dose exposures.
Purification and characterization of two enone reductases from Saccharomyces cerevisiae.
Wanner, P; Tressl, R
1998-07-01
Two enone reductases catalyzing irreversibly the enantioselective reduction of alpha,beta-unsaturated carbonyls have been purified 165-fold and 257-fold, respectively, from the cytosolic fraction of Saccharomyces cerevisiae by means of streptomycin sulfate treatment, Sephadex G-25 filtration, DEAE-Sepharose CL-6B chromatography, blue Sepharose CL-6B chromatography and Superdex 200 preparation-grade filtration. One enzyme (E I) was NADPH-dependent, showed a molecular mass of 75 kDa and decomposed under denaturing electrophoretic conditions into two subunits of 34 kDa and 37 kDa. The other enzyme (E II) was NADH linked and the molecular mass estimated by means of Superdex 200 preparation-grade filtration, was 130 kDa. The enzyme decomposed into subunits of 56 kDa and 64 kDa on SDS/PAGE. Both enzymes were most active at pH 4.8 and accepted 1-octen-3-one, 1-hexen-3-one, 3-alken-2-ones, 4-alken-3-ones, 2-cyclohexen-1-ones, 2-alkenals, 2,4-alkadienals, 2-phenyl-2-alkenals, and 2-alkyl-2-alkenals as substrates. Both enzymes showed their highest activities with 1-hexen-3-one and 1-octen-3-one, respectively. The Km values for 1-octen-3-one were estimated as 0.54 mM (E I) and 0.20 mM (E II), respectively. Both enzymes catalyzed the enantioselective reduction of cis- and trans-2-phenyl-2-butenal into (R)-2-phenylbutanal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A
Purpose: The purpose of this investigation is to characterize and quantify X-ray beam profiles for fluoroscopic x-ray beam spectra incorporating spectral (copper) filtration. Methods: A PTW (Freiburg, Germany) type 60016 silicon diode detector and PTW MP3 water tank were used to measure X-ray beam profiles for 60, 80, 100 and 120 kVp x-ray beams at five different copper filtration thicknesses ranging from 0–0.9 mm at 22 and 42 cm fields of view and depths of 1, 5, and 10 cm in both the anode-cathode axis (inplane) and cross-plane directions. All measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGomore » fluoroscope inverted from the typical orientation providing an x-ray beam originating from above the water surface with the water level set at 60 cm from the focal spot. Results: X-ray beam profiles for beam spectra without copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. Our data collection benefited from the geometric orientation of the fluoroscope, providing a beam perpendicular to the tank water surface, rather than through a thin side wall as did the previously mentioned study. Profiles for beams with copper filtration were obtained which have not been previously investigated and published. Beam profiles in the anode-cathode axis near the surface and at lower x-ray energy exhibited substantial heel effect, which became less pronounced at greater depth. At higher energy with copper filtration in the beam, the dose falloff out-of-field became less pronounced, as would be anticipated given higher scatter photon energy. Conclusion: The x-ray beam profile data for the fluoroscopic x-ray beams incorporating copper filtration are intended for use as reference data for estimating doses to organs or soft tissue, including fetal dose, involving similar beam qualities or for comparison with mathematical models.« less
Forced-air warming: a source of airborne contamination in the operating room?
Albrecht, Mark; Gauthier, Robert; Leaper, David
2009-10-10
Forced-air-warming (FAW) is an effective and widely used means for maintaining surgical normothermia, but FAW also has the potential to generate and mobilize airborne contamination in the operating room.We measured the emission of viable and non-viable forms of airborne contamination from an arbitrary selection of FAW blowers (n=25) in the operating room. A laser particle counter measured particulate concentrations of the air near the intake filter and in the distal hose airstream. Filtration efficiency was calculated as the reduction in particulate concentration in the distal hose airstream relative to that of the intake. Microbial colonization of the FAW blower's internal hose surfaces was assessed by culturing the microorganisms recovered through swabbing (n=17) and rinsing (n=9) techniques.Particle counting revealed that 24% of FAW blowers were emitting significant levels of internally generated airborne contamination in the 0.5 to 5.0 µm size range, evidenced by a steep decrease in FAW blower filtration efficiency for particles 0.5 to 5.0 µm in size. The particle size-range-specific reduction in efficiency could not be explained by the filtration properties of the intake filter. Instead, the reduction was found to be caused by size-range-specific particle generation within the FAW blowers. Microorganisms were detected on the internal air path surfaces of 94% of FAW blowers.The design of FAW blowers was found to be questionable for preventing the build-up of internal contamination and the emission of airborne contamination into the operating room. Although we did not evaluate the link between FAW and surgical site infection rates, a significant percentage of FAW blowers with positive microbial cultures were emitting internally generated airborne contamination within the size range of free floating bacteria and fungi (<4 µm) that could, conceivably, settle onto the surgical site.
Grubb, Anders; Horio, Masaru; Hansson, Lars-Olof; Björk, Jonas; Nyman, Ulf; Flodin, Mats; Larsson, Anders; Bökenkamp, Arend; Yasuda, Yoshinari; Blufpand, Hester; Lindström, Veronica; Zegers, Ingrid; Althaus, Harald; Blirup-Jensen, Søren; Itoh, Yoshi; Sjöström, Per; Nordin, Gunnar; Christensson, Anders; Klima, Horst; Sunde, Kathrin; Hjort-Christensen, Per; Armbruster, David; Ferrero, Carlo
2014-07-01
Many different cystatin C-based equations exist for estimating glomerular filtration rate. Major reasons for this are the previous lack of an international cystatin C calibrator and the nonequivalence of results from different cystatin C assays. Use of the recently introduced certified reference material, ERM-DA471/IFCC, and further work to achieve high agreement and equivalence of 7 commercially available cystatin C assays allowed a substantial decrease of the CV of the assays, as defined by their performance in an external quality assessment for clinical laboratory investigations. By use of 2 of these assays and a population of 4690 subjects, with large subpopulations of children and Asian and Caucasian adults, with their GFR determined by either renal or plasma inulin clearance or plasma iohexol clearance, we attempted to produce a virtually assay-independent simple cystatin C-based equation for estimation of GFR. We developed a simple cystatin C-based equation for estimation of GFR comprising only 2 variables, cystatin C concentration and age. No terms for race and sex are required for optimal diagnostic performance. The equation, [Formula: see text] is also biologically oriented, with 1 term for the theoretical renal clearance of small molecules and 1 constant for extrarenal clearance of cystatin C. A virtually assay-independent simple cystatin C-based and biologically oriented equation for estimation of GFR, without terms for sex and race, was produced. © 2014 The American Association for Clinical Chemistry.
Montañés Bermúdez, R; Gràcia Garcia, S; Fraga Rodríguez, G M; Escribano Subias, J; Diez de Los Ríos Carrasco, M J; Alonso Melgar, A; García Nieto, V
2014-05-01
The appearance of the K/DOQI guidelines in 2002 on the definition, evaluation and staging of chronic kidney disease (CKD) have led to a major change in how to assess renal function in adults and children. These guidelines, recently updated, recommended that the study of renal function is based, not only on measuring the serum creatinine concentration, but this must be accompanied by the estimation of glomerular filtration rate (GFR) obtained by an equation. However, the implementation of this recommendation in the clinical laboratory reports in the paediatric population has been negligible. Numerous studies have appeared in recent years on the importance of screening and monitoring of patients with CKD, the emergence of new equations for estimating GFR, and advances in clinical laboratories regarding the methods for measuring plasma creatinine and cystatin C, determined by the collaboration between the departments of paediatrics and clinical laboratories to establish recommendations based on the best scientific evidence on the use of equations to estimate GFR in this population. The purpose of this document is to provide recommendations on the evaluation of renal function and the use of equations to estimate GFR in children from birth to 18 years of age. The recipients of these recommendations are paediatricians, nephrologists, clinical biochemistry, clinical analysts, and all health professionals involved in the study and evaluation of renal function in this group of patients. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Evaluation of equations that estimate glomerular filtration rate in renal transplant recipients.
De Alencastro, M G; Veronese, F V; Vicari, A R; Gonçalves, L F; Manfro, R C
2014-03-01
The accuracy of equations that estimate the glomerular filtration rate (GFR) in renal transplant patients has not been established; thus their performance was assessed in stable renal transplant patients. Renal transplant patients (N.=213) with stable graft function were enrolled. The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation was used as the reference method and compared with the Cockcroft-Gault (CG), Modification of Diet in Renal Disease (MDRD), Mayo Clinic (MC) and Nankivell equations. Bias, accuracy and concordance rates were determined for all equation relative to CKD-EPI. Mean estimated GFR values of the equations differed significantly from the CKD-EPI values, though the correlations with the reference method were significant. Values of MDRD differed from the CG, MC and Nankivell estimations. The best agreement to classify the chronic kidney disease (CKD) stages was for the MDRD (Kappa=0.649, P<0.001), and for the other equations the agreement was moderate. The MDRD had less bias and narrower agreement limits but underestimated the GFR at levels above 60 mL/min/1.73 m2. Conversely, the CG, MC and Nankivell equations overestimated the GFR, and the Nankivell equation had the worst performance. The MDRD equation P15 and P30 values were higher than those of the other equations (P<0.001). Despite their correlations, equations estimated the GFR and CKD stage differently. The MDRD equation was the most accurate, but the sub-optimal performance of all the equations precludes their accurate use in clinical practice.
Murayama, I; Miyano, A; Sasaki, Y; Hirata, T; Ichijo, T; Satoh, H; Sato, S; Furuhama, K
2013-11-01
This study was performed to clarify whether a formula (Holstein equation) based on a single blood sample and the isotonic, nonionic, iodine contrast medium iodixanol in Holstein dairy cows can apply to the estimation of glomerular filtration rate (GFR) for beef cattle. To verify the application of iodixanol in beef cattle, instead of the standard tracer inulin, both agents were coadministered as a bolus intravenous injection to identical animals at doses of 10 mg of I/kg of BW and 30 mg/kg. Blood was collected 30, 60, 90, and 120 min after the injection, and the GFR was determined by the conventional multisample strategies. The GFR values from iodixanol were well consistent with those from inulin, and no effects of BW, age, or parity on GFR estimates were noted. However, the GFR in cattle weighing less than 300 kg, aged<1 yr old, largely fluctuated, presumably due to the rapid ruminal growth and dynamic changes in renal function at young adult ages. Using clinically healthy cattle and those with renal failure, the GFR values estimated from the Holstein equation were in good agreement with those by the multisample method using iodixanol (r=0.89, P=0.01). The results indicate that the simplified Holstein equation using iodixanol can be used for estimating the GFR of beef cattle in the same dose regimen as Holstein dairy cows, and provides a practical and ethical alternative.
Analysis of Wellbore Skin Samples-Typology, Composition, and Hydraulic Properties.
Houben, Georg J; Halisch, Matthias; Kaufhold, Stephan; Weidner, Christoph; Sander, Jürgen; Reich, Morris
2016-09-01
The presence of a wellbore skin layer, formed during the drilling process, is a major impediment for the energy-efficient use of water wells. Many models exist that predict its potential impacts on well hydraulics, but so far its relevant hydraulic parameters were only estimates or, at best, model results. Here, we present data on the typology, thickness, composition, and hydraulic properties obtained from the sampling of excavated dewatering wells in lignite surface mines and from inclined core drilling into the annulus of an abandoned water well. Despite the limited number of samples, several types of skin were identified. Both surface cake filtration and particle straining in the aquifer occur. The presence of microcracks may be a determining feature for the hydraulic conductivity of skin layers. In the case of the well-developed water supply well, no skin layer was detected. The observed types and properties of wellbore skin samples can be used to test the many mathematical skin models. © 2016, National Ground Water Association.
Removal of adenovirus, calicivirus, and bacteriophages by conventional drinking water treatment.
Abbaszadegan, Morteza; Monteiro, Patricia; Nwachuku, Nena; Alum, Absar; Ryu, Hodon
2008-02-01
This study was conducted to evaluate the removal of adenovirus, feline calicivirus (FCV), and bacteriophages MS-2, fr, PRD-1, and Phi X-174 during conventional drinking water treatment using ferric chloride as a coagulant. Adenovirus and FCV were removed to a greater extent than PRD-1 and Phi X-174, indicating that these bacteriophages may be appropriate surrogates for both adenovirus and FCV. Of the four bacteriophages studied in the pilot plant, MS-2 was removed to the greatest extent (5.1 log), followed by fr (4.9 log), PRD-1 (3.5 log), and Phi X-174 (1.3 log). The virus removal trend in the pilot-scale testing was similar to the bench-scale testing; however, the bench-scale testing seemed to provide a conservative estimate of the pilot plant performance. In the pilot-scale testing, MS-2 and fr were removed with the greatest efficiency during filtration, whereas PRD-1 and Phi X-174 showed the greatest removal during sedimentation.
Day, D B; Xiang, J; Mo, J; Clyde, M A; Weschler, C J; Li, F; Gong, J; Chung, M; Zhang, Y; Zhang, J
2018-05-01
High-efficiency particulate air (HEPA) filtration in combination with an electrostatic precipitator (ESP) can be a cost-effective approach to reducing indoor particulate exposure, but ESPs produce ozone. The health effect of combined ESP-HEPA filtration has not been examined. We conducted an intervention study in 89 volunteers. At baseline, the air-handling units of offices and residences for all subjects were comprised of coarse, ESP, and HEPA filtration. During the 5-week long intervention, the subjects were split into 2 groups, 1 with just the ESP removed and the other with both the ESP and HEPA removed. Each subject was measured for cardiopulmonary risk indicators once at baseline, twice during the intervention, and once 2 weeks after baseline conditions were restored. Measured indoor and outdoor PM 2.5 and ozone concentrations, coupled with time-activity data, were used to calculate exposures. Removal of HEPA filters increased 24-hour mean PM 2.5 exposure by 38 (95% CI: 31, 45) μg/m 3 . Removal of ESPs decreased 24-hour mean ozone exposure by 2.2 (2.0, 2.5) ppb. No biomarkers were significantly associated with HEPA filter removal. In contrast, ESP removal was associated with a -16.1% (-21.5%, -10.4%) change in plasma-soluble P-selectin and a -3.0% (-5.1%, -0.8%) change in systolic blood pressure, suggesting reduced cardiovascular risks. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Chen, Chong-Jun; Zhang, Rui; Xiang, Kun; Wu, Wei-Xiang
2014-08-01
Unorganized discharge of greenhouse turtle breeding wastewater has brought several negative influences on the ecological environment in the rural area of Yangtze River Delta. Biological filtration and vegetable floating-bed combined system is a potential ecological method for greenhouse turtle breeding wastewater treatment. In order to explore the feasibility of this system and evaluate the contribution of vegetable uptake of nitrogen (N) and phosphorus (P) in treating greenhouse turtle breeding wastewater, three types of vegetables, including Ipomoea aquatica, lettuce and celery were selected in this study. Results showed the combined system had a high capacity in simultaneous removal of organic matter, N and P. The removal efficiencies of COD, NH4(+)-N, TN and TP from the wastewater reached up to 93.2%-95.6%, 97.2%-99.6%, 73.9%-93.1% and 74.9%-90.0%, respectively. System with I. aquatica had the highest efficiencies in N and P removal, followed by lettuce and celery. However, plant uptake was not the primary pathway for TN arid TP removal in the combined system. The vegetable uptake of N and P accounted for only 9.1%-25.0% of TN and TP removal from the wastewater while the effect of microorganisms would be dominant for N and P removal. In addition, the highest amounts of N and P uptake in I. aquatica were closely related with the biomass of plant. Results from the study indicated that the biological filtration and vegetable floating-bed combined system was an effective approach to treating greenhouse turtle breeding wastewater in China.
SLUDGE PARTICLE SEPAPATION EFFICIENCIES DURING SETTLER TANK RETRIEVAL INTO SCS-CON-230
DOE Office of Scientific and Technical Information (OSTI.GOV)
DEARING JI; EPSTEIN M; PLYS MG
2009-07-16
The purpose of this document is to release, into the Hanford Document Control System, FA1/0991, Sludge Particle Separation Efficiencies for the Rectangular SCS-CON-230 Container, by M. Epstein and M. G. Plys, Fauske & Associates, LLC, June 2009. The Sludge Treatment Project (STP) will retrieve sludge from the 105-K West Integrated Water Treatment System (IWTS) Settler Tanks and transfer it to container SCS-CON-230 using the Settler Tank Retrieval System (STRS). The sludge will enter the container through two distributors. The container will have a filtration system that is designed to minimize the overflow of sludge fines from the container to themore » basin. FAI/09-91 was performed to quantify the effect of the STRS on sludge distribution inside of and overflow out of SCS-CON-230. Selected results of the analysis and a system description are discussed. The principal result of the analysis is that the STRS filtration system reduces the overflow of sludge from SCS-CON-230 to the basin by roughly a factor of 10. Some turbidity can be expected in the center bay where the container is located. The exact amount of overflow and subsequent turbidity is dependent on the density of the sludge (which will vary with location in the Settler Tanks) and the thermal gradient between the SCS-CON-230 and the basin. Attachment A presents the full analytical results. These results are applicable specifically to SCS-CON-230 and the STRS filtration system's expected operating duty cycles.« less
Zheng, Junjian; Wang, Zhiwei; Ma, Jinxing; Xu, Shaoping; Wu, Zhichao
2018-04-03
Inability to remove low-molecular-weight anthropogenic contaminants is a critical issue in low-pressure membrane filtration processes for water treatment. In this work, a novel electrochemical ceramic membrane filtration (ECMF) system using TiO 2 @SnO 2 -Sb anode was developed for removing persistent p-chloroaniline (PCA). Results showed that the ECMF system achieved efficient removal of PCA from contaminated waters. At a charging voltage of 3 V, the PCA removal rate of TiO 2 @SnO 2 -Sb ECMF system under flow-through mode was 2.4 times that of flow-by mode. The energy consumption for 50% of PCA removal for TiO 2 @SnO 2 -Sb ECMF at 3 V under flow-through mode was 0.38 Wh/L, much lower than that of flow-by operation (1.5 Wh/L), which was attributed to the improved utilization of the surface adsorbed HO· and dissociated HO· driven by the enhanced mass transfer of PCA toward the anode surface. Benefiting from the increased production of reactive oxygen species such as O 2 •- , H 2 O 2 , and HO· arising from excitation of anatase TiO 2 , TiO 2 @SnO 2 -Sb ECMF exhibited a superior electrocatalytic activity to the SnO 2 -Sb ECMF system. The degradation pathways of PCA initiated by OH· attack were further proposed, with the biodegradable short-chain carboxylic acids (mainly formic, acetic, and oxalic acids) identified as the dominant oxidized products. These results highlight the potential of the ECMF system for cost-effective water purification.
USDA-ARS?s Scientific Manuscript database
Background: Anticoagulation management is difficult in chronic kidney disease, with frequent supratherapeutic international normalized ratios (INRs >/= 4) increasing hemorrhagic risk. We evaluated whether the interaction of INR and lower estimated glomerular filtration rate (eGFR) increases hemorrha...
Lifestyle factors and indices of kidney function in the Framingham Heart Study
USDA-ARS?s Scientific Manuscript database
Background and objectives: Lifestyle characteristics are modifiable factors that could be targeted as part of chronic kidney disease (CKD) prevention. We sought to determine the association of lifestyle characteristics with incident estimated glomerular filtration rate (eGFR)<60mL/min/1.73m2 and rap...
Tunc, Talip; Sahin, Ustun
2016-04-01
The objective of this 2-year field study was to evaluate the effects of drip irrigation with urban wastewaters reclaimed using primary (filtration) and secondary (filtration and aeration) processes on red cabbage growth and fresh yield, heavy metal content, water use and efficiency and soil chemical properties. Filtered wastewater (WW1), filtered and aerated wastewater (WW2), freshwater and filtered wastewater mix (1:1 by volume) (WW3) and freshwater (FW) were investigated as irrigation water treatments. Crop evapotranspiration decreased significantly, while water use efficiency increased under wastewater treatments compared to FW. WW1 treatment had the lowest value (474.2 mm), while FW treatments had the highest value (556.7 mm). The highest water use efficiency was found in the WW1 treatment as 8.41 kg m(-3), and there was a twofold increase with regard to the FW. Wastewater irrigation increased soil fertility and therefore red cabbage yield. WW2 treatment produced the highest total fresh yield (40.02 Mg ha(-1)). However, wastewater irrigation increased the heavy metal content in crops and soil. Cd content in red cabbage heads was above the safe limit, and WW1 treatment had the highest value (0.168 mg kg(-1)). WW3 treatment among wastewater treatments is less risky in terms of soil and crop heavy metal pollution and faecal coliform contamination. Therefore, WW3 wastewater irrigation for red cabbage could be recommended for higher yield and water efficiency with regard to freshwater irrigation.
Long-term evaluation of the performance of four point-of-use water filters.
Pérez-Vidal, Andrea; Diaz-Gómez, Jaime; Castellanos-Rozo, Jose; Usaquen-Perilla, Olga Lucía
2016-07-01
Despite technological advances water supply quality and poor access to safe water remain a major problem in developing countries, especially in rural areas. Point-of-use (POU) water treatment has been shown to be a viable option to produce safe drinking water quality. The aim of this study was to evaluate, under laboratory conditions over 14 months, the performance of four household filtration systems: membrane filter (MF), one-candle ceramic filter (1CCF), two-candle ceramic filter (2CCF) and pot ceramic filter (PCF). The evaluation was made using spiked water having the required concentrations of turbidity, Escherichia coli and Total Dissolved Solids (TDS). The results show that all systems have high removal efficiencies for turbidity (98-99%), and E. coli 4-5 Log Reduction Value (LRV). The poorest efficiency was for TDS (9-18%). The MF and the CCF displayed no significant difference in efficiencies for these parameters. The PCF had less significant differences for turbidity removal than the other systems. The average filtration rate for all systems decreased during the operation time. The CPF showed the major potential to be used in rural communities mainly for its low operational level and maintenance requirements as well as its local craftsmanship. It was observed that the efficiency of the systems is highly sensitive to cleaning and maintenance activities and therefore, the system sustainability will depend considerably on the training and education of the potential users. Copyright © 2016 Elsevier Ltd. All rights reserved.
Wu, Xuan; Tan, Ke-Yan; Hu, Xi-Jia; Gu, Yun; Yang, Hong
2014-04-01
At the temperature of 18.0-22.3 degrees C, biological carriers were produce from pure SRB and zeolite by the embedding immobilized method, and a sulfate-reducing biological filter filled with filter carriers was built to treat cadmium-containing wastewater. Experimental research on removal efficiency of Cd2+, COD and SO4(2-) in wastewater by the biological filter was carried out after SRB domestication. Results show that cadmium can be removed satisfactorily from wastewater using SRB by the biological filter filled with sulfate-reducing bacteria. When the filtration rate was 0.4 m x h(-1) and the cadmium concentration in wastewater was not more than 15 mg x L(-1), the processing efficiency was the best. In the formal running period, the removal rates of Cd2+, COD and SO4(2-) by the biological filter were more than 99%, 75% and 50%. The effluent Cd2+ concentration was less than 0.1 mg x L(-1), which could meet the cadmium emission requirements in the wastewater quality standards for discharge to municipal sewers (CJ 343-2010). The removal of Cd2+, COD and SO4(2-) by biological filter mainly occurs in the top 60 cm of the filter bed during stable operation. When the filtration rate was less than 0.6 m x h(-1), Cd(2+) can be removed by the biological filter with high efficiency and stability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... filtration. (1) For systems using diatomaceous earth filtration, the turbidity level of representative... PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.73 Filtration. A public water system... treatment or direct filtration. (1) For systems using conventional filtration or direct filtration, the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... filtration. (1) For systems using diatomaceous earth filtration, the turbidity level of representative... PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.73 Filtration. A public water system... treatment or direct filtration. (1) For systems using conventional filtration or direct filtration, the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... filtration. (1) For systems using diatomaceous earth filtration, the turbidity level of representative... PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.73 Filtration. A public water system... treatment or direct filtration. (1) For systems using conventional filtration or direct filtration, the...
Analysis of radon and thoron progeny measurements based on air filtration.
Stajic, J M; Nikezic, D
2015-02-01
Measuring of radon and thoron progeny concentrations in air, based on air filtration, was analysed in order to assess the reliability of the method. Changes of radon and thoron progeny activities on the filter during and after air sampling were investigated. Simulation experiments were performed involving realistic measuring parameters. The sensitivity of results (radon and thoron concentrations in air) to the variations of alpha counting in three and five intervals was studied. The concentration of (218)Po showed up to be the most sensitive to these changes, as was expected because of its short half-life. The well-known method for measuring of progeny concentrations based on air filtration is rather unreliable and obtaining unrealistic or incorrect results appears to be quite possible. A simple method for quick estimation of radon potential alpha energy concentration (PAEC), based on measurements of alpha activity in a saturation regime, was proposed. Thoron PAEC can be determined from the saturation activity on the filter, through beta or alpha measurements. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Purification of human alpha uterine protein.
Sutcliffe, R G; Bolton, A E; Sharp, F; Nicholson, L V; MacKinnon, R
1980-03-01
Human alpha uterine protein (AUP) has been prepared from extracts of decudua by antibody affinity chromatography, DEAE Sepharose chromatography and by filtration through Sephadex G-150. This procedure yielded a protein fraction containing AUP, which was labelled with 125I by chloramine T. When analysed by SDS gel electrophoresis this radioiodinated protein fraction was found to contain predominantly a single species of protein which was precipitated by antibodies against AUP in antibody-antigen crossed electrophoresis. Rabbit anti-AUP precipitated 55-65% of the tracer in a double-antibody system. Sephadex G150 gel filtration of AUP obtained before and after affinity chromatography provided a molecular weight estimate of 50000. Since SDS gel electrophoresis revealed a polypeptide molecular weight of 23000-25000, it is suggested that AUP is a dimer.
What to do after nutrient removal?
van der Graaf, J H
2001-01-01
In the Netherlands, interest in advanced treatment is increasing now that almost all wastewater treatment plants apply full biological treatment and nutrient removal. The resulting effluents have an excellent quality which can be improved further by applying advanced treatment processes like flocculating filtration, membrane filtration, UV or activated carbon, and others. The treated effluent can be re-used for various purposes, as process water, household water, urban water, for groundwater suppletion and drinking water. Nowadays many applications are investigated. In order to confirm the applicability pilot test investigations are done at various WWTPs. The results are promising; the cost estimations show increasing prospects. This will finally lead to the maturity of the advanced treatment. It will certainly contribute to a more sustainable water cycle.
Bromate formation in a hybrid ozonation-ceramic membrane filtration system.
Moslemi, Mohammadreza; Davies, Simon H; Masten, Susan J
2011-11-01
The effect of pH, ozone mass injection rate, initial bromide concentration, and membrane molecular weight cut off (MWCO) on bromate formation in a hybrid membrane filtration-ozonation reactor was studied. Decreasing the pH, significantly reduced bromate formation. Bromate formation increased with increasing gaseous ozone mass injection rate, due to increase in dissolved ozone concentrations. Greater initial bromide concentrations resulted in higher bromate concentrations. An increase in the bromate concentration was observed by reducing MWCO, which resulted in a concomitant increase in the retention time in the system. A model to estimate the rate of bromate formation was developed. Good correlation between the model simulation and the experimental data was achieved. Copyright © 2011 Elsevier Ltd. All rights reserved.
Nanoceramics for blood-borne virus removal.
Zhao, Yufeng; Sugiyama, Sadahiro; Miller, Thomas; Miao, Xigeng
2008-05-01
The development of nanoscience and nanotechnology in the field of ceramics has brought new opportunities for the development of virus-removal techniques. A number of nanoceramics, including nanostructured alumina, titania and zirconia, have been introduced for the applications in virus removal or separation. Filtration or adsorption of viruses, and thus the removal of viruses through nanoceramics, such as nanoporous/mesoporous ceramic membranes, ceramic nanofibers and ceramic nanoparticles, will make it possible to produce an efficient system for virus removal from blood and one with excellent chemical/thermal stability. Currently, nanoceramic membranes and filters based on sol-gel alumina membranes and NanoCeram nanofiber filters have been commercialized and applied to remove viruses from the blood. Nevertheless, filtration using nanoporous filters is limited to the removal of only free viruses in the bloodstream.
Pearson, D T; Watson, B G; Waterhouse, P S
1978-01-01
The ability of 12 commercially available cardiotomy reservoirs to remove bubbles from aspirated blood was investigated by means of a simulated cardiopulmonary bypass circuit and an ultrasonic microbubble detector. Performance varied considerably. The number of gaseous microemboli remaining after passage of blood through the reservoir was reduced by (a) holding the blood in the reservoir, (b) reducing the volume of air mixed with the aspirated blood, and (c) using a reservoir that did not induce turbulence and that contained integral micropore filtration material. Further micropore filtration of the blood after passage through the cardiotomy reservoir was beneficial, and significantly more bubbles were extracted when the microfilter was sited below the reservoir than when it was placed in the arterial line. PMID:684672
Filtration of human EEG recordings from physiological artifacts with empirical mode method
NASA Astrophysics Data System (ADS)
Grubov, Vadim V.; Runnova, Anastasiya E.; Khramova, Marina V.
2017-03-01
In the paper we propose the new method for dealing with noise and physiological artifacts in experimental human EEG recordings. The method is based on analysis of EEG signals with empirical mode decomposition (Hilbert-Huang transform). We consider noises and physiological artifacts on EEG as specific oscillatory patterns that cause problems during EEG analysis and can be detected with additional signals recorded simultaneously with EEG (ECG, EMG, EOG, etc.) We introduce the algorithm of the method with following steps: empirical mode decomposition of EEG signal, choosing of empirical modes with artifacts, removing empirical modes with artifacts, reconstruction of the initial EEG signal. We test the method on filtration of experimental human EEG signals from eye-moving artifacts and show high efficiency of the method.
Risch, Martin; Risch, Lorenz; Purde, Mette-Triin; Renz, Harald; Ambühl, Patrice; Szucs, Thomas; Tomonaga, Yuki
2016-09-01
The ratio of cystatin C to creatinine (cysC/crea) is regarded as a marker of glomerular filtration quality and predicts mortality. It has been hypothesized that increased mortality may be mediated by the retention of biologically active substances due to shrinking glomerular pores. The present study investigated whether cysC/crea is independently associated with the levels of two renally cleared hormones, which have been linked to increased mortality. We conducted a multicenter, cross-sectional study with a random selection of general practitioners (GPs) from all GP offices in seven Swiss cantons. Markers of glomerular filtration quality were investigated together with estimated glomerular filtration rate (eGFR), albuminuria and urinary neutrophil gelatinase associated lipocalin (uNGAL) as well as two renally cleared low-molecular-weight protein hormones (i.e. BNP and PTH), Morbidity was assessed with the Charlson Comorbidity Index (CCI). A total of 1000 patients (433 males; mean age 57 ± 17 years) were included. There was a significant univariate association of BNP (r = 0.36, p < 0.001) and PTH (r = 0.18, p < 0.001) with cysC/crea. An adjusted model that accounted for kidney function (eGFR), altered glomerular structure (albuminuria), renal stress (uNGAL), and CCI showed that BNP and PTH were independently associated with cysC/crea as well as with the ratio of cystatin C-based to creatinine-based eGFR. In conclusion, in primary care patients, BNP and PTH are independently associated both with markers of glomerular filtration quality and eGFR regardless of structural kidney damage or renal stress. These findings offer an explanation, how altered glomerular filtration quality could contribute to increased mortality.
Renal Blood Flow, Glomerular Filtration Rate, and Renal Oxygenation in Early Clinical Septic Shock.
Skytte Larsson, Jenny; Krumbholz, Vitus; Enskog, Anders; Bragadottir, Gudrun; Redfors, Bengt; Ricksten, Sven-Erik
2018-06-01
Data on renal hemodynamics, function, and oxygenation in early clinical septic shock are lacking. We therefore measured renal blood flow, glomerular filtration rate, renal oxygen consumption, and oxygenation in patients with early septic shock. Prospective comparative study. General and cardiothoracic ICUs. Patients with norepinephrine-dependent early septic shock (n = 8) were studied within 24 hours after arrival in the ICU and compared with postcardiac surgery patients without acute kidney injury (comparator group, n = 58). None. Data on systemic hemodynamics and renal variables were obtained during two 30-minute periods. Renal blood flow was measured by the infusion clearance of para-aminohippuric acid, corrected for renal extraction of para-aminohippuric acid. Renal filtration fraction was measured by renal extraction of chromium-51 labeled EDTA. Renal oxygenation was estimated from renal oxygen extraction. Renal oxygen delivery (-24%; p = 0.037) and the renal blood flow-to-cardiac index ratio (-21%; p = 0.018) were lower, renal vascular resistance was higher (26%; p = 0.027), whereas renal blood flow tended to be lower (-19%; p = 0.068) in the septic group. Glomerular filtration rate (-32%; p = 0.006) and renal sodium reabsorption (-29%; p = 0.014) were both lower in the septic group. Neither renal filtration fraction nor renal oxygen consumption differed significantly between groups. Renal oxygen extraction was significantly higher in the septic group (28%; p = 0.022). In the septic group, markers of tubular injury were elevated. In early clinical septic shock, renal function was lower, which was accompanied by renal vasoconstriction, a lower renal oxygen delivery, impaired renal oxygenation, and tubular sodium reabsorption at a high oxygen cost compared with controls.
Agoons, D D; Balti, E V; Kaze, F F; Azabji-Kenfack, M; Ashuntantang, G; Kengne, A P; Sobngwi, E; Mbanya, J C
2016-09-01
We evaluated the performance of the Modification of Diet in Renal Disease (MDRD), Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) and Cockcroft-Gault (CG) equations against creatinine clearance (CrCl) to estimate glomerular filtration rate (GFR) in 51 patients with Type 2 diabetes. The CrCl value was obtained from the average of two consecutive 24-h urine samples. Results were adjusted for body surface area using the Dubois formula. Serum creatinine was measured using the kinetic Jaffe method and was calibrated to standardized levels. Bland-Altman analysis and kappa statistic were used to examine agreement between measured and estimated GFR. Estimates of GFR from the CrCl, MDRD, CKD-EPI and CG equations were similar (overall P = 0.298), and MDRD (r = 0.58; 95% CI: 0.36-0.74), CKD-EPI (r = 0.55; 95% CI: 0.33-0.72) and CG (r = 0.61; 95% CI: 0.39-0.75) showed modest correlation with CrCl (all P < 0.001). Bias was -0.3 for MDRD, 1.7 for CKD-EPI and -5.4 for CG. All three equations showed fair-to-moderate agreement with CrCl (kappa: 0.38-0.51). The c-statistic for all three equations ranged between 0.75 and 0.77 with no significant difference (P = 0.639 for c-statistic comparison). The MDRD equation seems to have a modest advantage over CKD-EPI and CG in estimating GFR and detecting impaired renal function in sub-Saharan African patients with Type 2 diabetes. The overall relatively modest correlation with CrCl, however, suggests the need for context-specific estimators of GFR or context adaptation of existing estimators. © 2015 Diabetes UK.
van Deventer, Hendrick E; George, Jaya A; Paiker, Janice E; Becker, Piet J; Katz, Ivor J
2008-07-01
The 4-variable Modification of Diet in Renal Disease (4-v MDRD) and Cockcroft-Gault (CG) equations are commonly used for estimating glomerular filtration rate (GFR); however, neither of these equations has been validated in an indigenous African population. The aim of this study was to evaluate the performance of the 4-v MDRD and CG equations for estimating GFR in black South Africans against measured GFR and to assess the appropriateness for the local population of the ethnicity factor established for African Americans in the 4-v MDRD equation. We enrolled 100 patients in the study. The plasma clearance of chromium-51-EDTA ((51)Cr-EDTA) was used to measure GFR, and serum creatinine was measured using an isotope dilution mass spectrometry (IDMS) traceable assay. We estimated GFR using both the reexpressed 4-v MDRD and CG equations and compared it to measured GFR using 4 modalities: correlation coefficient, weighted Deming regression analysis, percentage bias, and proportion of estimated GFR within 30% of measured GFR (P(30)). The Spearman correlation coefficient between measured and estimated GFR for both equations was similar (4-v MDRD R(2) = 0.80 and CG R(2) = 0.79). Using the 4-v MDRD equation with the ethnicity factor of 1.212 as established for African Americans resulted in a median positive bias of 13.1 (95% CI 5.5 to 18.3) mL/min/1.73 m(2). Without the ethnicity factor, median bias was 1.9 (95% CI -0.8 to 4.5) mL/min/1.73 m(2). The 4-v MDRD equation, without the ethnicity factor of 1.212, can be used for estimating GFR in black South Africans.
The federal standard for the presence of asbestos in drinking water mandates the use of transmission electron microscopy (TEM) as the only acceptable testing method. The July 17, 1992 Federal Register (57 FR 31839, Section 141.23(k)(4)) specifies that the analysis for as...
De Rocker, E; Goen, K; Van Poucke, K
2006-01-01
The efficiency of the disinfection of drain water was tested at 11 greenhouses with tomato cultivation on rockwool substrate in Flanders (Belgium) by means of mycological analysis. In addition the presence of phytopathogenic fungi in the drain water was analysed at 2 supplementary greenhouses with recirculation without disinfection.
Bojinova, Darinka; Teodosieva, Ralitsa
2016-06-01
The solid industrial wastes generated from thermal power plants (TPPs) can be considered as renewable secondary sources for recovery of valuable metals. This study presents the results from investigations that integrated a thermo-hydro-metallurgical method for treatment of bottom ash obtained from the Enel Maritsa East 3 TPP in Bulgaria. Leaching was performed with 20, 30 and 40 wt% sulphuric acid, respectively, in an autoclave at 100(o)C, 120(o)C and 140(o)C for 120, 240, 360 and 480 min, at a constant value of the liquid/solid ratio. After autoclaving, the samples (suspensions) were diluted with a constant value of water and stirring at 50(o)C for 60 min. On the basis of the experimental data the leaching efficiency (α) of the elements in the liquid phase after filtration was estimated. The leaching of aluminium increases significantly with increasing of the temperature, reaching the maximum value of 70 wt%. The highest leaching efficiency values for the other elements are as follows: Fe (86.4%), Ca (86.6%), Na (86.6%), Ni (83.3%) and Zn (83.3%). The maximum value of leaching for Mg, K, Mn, Cu and Cr is in the interval of 46-70%. © The Author(s) 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bjoerk, M.; Gilek, M.
1999-04-01
A novel method was used to estimate assimilation efficiencies (AEs) of dissolved and food associated PCBs (IUPAC 31, 49, and 153) by the Baltic Sea blue mussel (Mytilus edulis). Mussels were exposed to radiolabeled PCBs in a series of short-term toxicokinetic experiments at different algal food concentrations, both at apparent steady-state (ASS) and non-steady-state (NSS) conditions in respect to PCB partitioning between water and algae. The PCB AEs were calculated using a physiologically based bioaccumulation model where experimentally determined uptake and exposure rates at ASS and NSS conditions were combined into linear equation systems, which were solved for PCB AEmore » from water and food. A positive relationship between PCB uptake and algae clearance by the mussels was observed for all three PCBs. The PCB AEs from both water and food increased with congener hydrophobicity (octanol/water partition coefficient [K{sub ow}]), but AEs decreased with increases in water pumping and filtration rate of the mussels, respectively. The average contribution of food-associated PCB to the total uptake also increased with K{sub ow} from approximately 30% for PCB 31 and PCB 49 to 50% for PCB 153, mainly as a consequence of increased sorption to the algal food.« less
Object-oriented Persistent Homology
Wang, Bao; Wei, Guo-Wei
2015-01-01
Persistent homology provides a new approach for the topological simplification of big data via measuring the life time of intrinsic topological features in a filtration process and has found its success in scientific and engineering applications. However, such a success is essentially limited to qualitative data classification and analysis. Indeed, persistent homology has rarely been employed for quantitative modeling and prediction. Additionally, the present persistent homology is a passive tool, rather than a proactive technique, for classification and analysis. In this work, we outline a general protocol to construct object-oriented persistent homology methods. By means of differential geometry theory of surfaces, we construct an objective functional, namely, a surface free energy defined on the data of interest. The minimization of the objective functional leads to a Laplace-Beltrami operator which generates a multiscale representation of the initial data and offers an objective oriented filtration process. The resulting differential geometry based object-oriented persistent homology is able to preserve desirable geometric features in the evolutionary filtration and enhances the corresponding topological persistence. The cubical complex based homology algorithm is employed in the present work to be compatible with the Cartesian representation of the Laplace-Beltrami flow. The proposed Laplace-Beltrami flow based persistent homology method is extensively validated. The consistence between Laplace-Beltrami flow based filtration and Euclidean distance based filtration is confirmed on the Vietoris-Rips complex for a large amount of numerical tests. The convergence and reliability of the present Laplace-Beltrami flow based cubical complex filtration approach are analyzed over various spatial and temporal mesh sizes. The Laplace-Beltrami flow based persistent homology approach is utilized to study the intrinsic topology of proteins and fullerene molecules. Based on a quantitative model which correlates the topological persistence of fullerene central cavity with the total curvature energy of the fullerene structure, the proposed method is used for the prediction of fullerene isomer stability. The efficiency and robustness of the present method are verified by more than 500 fullerene molecules. It is shown that the proposed persistent homology based quantitative model offers good predictions of total curvature energies for ten types of fullerene isomers. The present work offers the first example to design object-oriented persistent homology to enhance or preserve desirable features in the original data during the filtration process and then automatically detect or extract the corresponding topological traits from the data. PMID:26705370
Active osmotic exchanger for advanced filtration at the nano scale
NASA Astrophysics Data System (ADS)
Marbach, Sophie; Bocquet, Lyderic
2015-11-01
One of the main functions of the kidney is to remove the waste products of an organism, mostly by excreting concentrated urea while reabsorbing water and other molecules. The human kidney is capable of recycling about 200 liters of water per day, at the relatively low cost of 0.5 kJ/L (standard dialysis requiring at least 150 kJ/L). Kidneys are constituted of millions of parallel filtration networks called nephrons. The nephrons of all mammalian kidneys present a specific loop geometry, the Loop of Henle, that is believed to play a key role in the urinary concentrating mechanism. One limb of the loop is permeable to water and the other contains sodium pumps that exchange with a common interstitium. In this work, we take inspiration from this osmotic exchanger design to propose new nanofiltration principles. We first establish simple analytical results to derive general operating principles, based on coupled water permeable pores and osmotic pumps. The best filtration geometry, in terms of power required for a given water recycling ratio, is comparable in many ways to the mammalian nephron. It is not only more efficient than traditional reverse osmosis systems, but can also work at much smaller pressures (of the order of the blood pressure, 0.13 bar, as compared to more than 30 bars for pressure-retarded osmosis systems). We anticipate that our proof of principle will be a starting point for the development of new filtration systems relying on the active osmotic exchanger principle.
Rigobello, Eliane Sloboda; Dantas, Angela Di Bernardo; Di Bernardo, Luiz; Vieira, Eny Maria
2013-06-01
This study was carried out to evaluate the efficiency of conventional drinking water treatment processes with and without pre-oxidation with chlorine and chlorine dioxide and the use of granular activated carbon (GAC) filtration for the removal of diclofenac (DCF). Water treatment was performed using the Jar test with filters on a lab scale, employing nonchlorinated artesian well water prepared with aquatic humic substances to yield 20HU true color, kaolin turbidity of 70 NTU and 1mgL(-1) DCF. For the quantification of DCF in water samples, solid phase extraction and HPLC-DAD methods were developed and validated. There was no removal of DCF in coagulation with aluminum sulfate (3.47mgAlL(-1) and pH=6.5), flocculation, sedimentation and sand filtration. In the treatment with pre-oxidation and disinfection, DCF was partially removed, but the concentration of dissolved organic carbon (DOC) was unchanged and byproducts of DCF were observed. Chlorine dioxide was more effective than chorine in oxidizing DCF. In conclusion, the identification of DCF and DOC in finished water indicated the incomplete elimination of DCF through conventional treatments. Nevertheless, conventional drinking water treatment followed by GAC filtration was effective in removing DCF (⩾99.7%). In the oxidation with chlorine, three byproducts were tentatively identified, corresponding to a hydroxylation, aromatic substitution of one hydrogen by chlorine and a decarboxylation/hydroxylation. Oxidation with chlorine dioxide resulted in only one byproduct (hydroxylation). Copyright © 2013 Elsevier Ltd. All rights reserved.
Vieno, Niina M; Härkki, Heli; Tuhkanen, Tuula; Kronberg, Leif
2007-07-15
The occurrence of four beta blockers, one antiepileptic drug, one lipid regulator, four anti-inflammatories, and three fluoroquinolones was studied in a river receiving sewage effluents. All compounds but two of the fluoroquinolones were observed in the water above their limit of quantification concentrations. The highest concentrations (up to 107 ng L(-1)) of the compounds were measured during the winter months. The river water was passed to a pilot-scale drinking water treatment plant, and the elimination of the pharmaceuticals was followed during the treatment. The processes applied by the plant consisted of ferric salt coagulation, rapid sand filtration, ozonation, two-stage granular activated carbon filtration (GAC), and UV disinfection. Following the coagulation, sedimentation, and rapid sand filtration, the studied pharmaceuticals were found to be eliminated only by an average of 13%. An efficient elimination was found to take place during ozonation at an ozone dose of about 1 mg L(-1) (i.e., 0.2-0.4 mg of O3/ mg of TOC). Following this treatment, the concentrations of the pharmaceuticals dropped to below the quantification limits with the exception of ciprofloxacin. Atenolol, sotalol, and ciprofloxacin, the most hydrophilic of the studied pharmaceuticals, were not fully eliminated during the GAC filtrations. All in all, the treatment train was found to very effectively eliminate the pharmaceuticals from the rawwater. The only compound that was found to pass almost unaffected through all the treatment steps was ciprofloxacin.
Fisk, W J; Chan, W R
2017-01-01
Increases in hospital admissions and deaths are associated with increases in outdoor air particles during wildfires. This analysis estimates the health benefits expected if interventions had improved particle filtration in homes in Southern California during a 10-day period of wildfire smoke exposure. Economic benefits and intervention costs are also estimated. The six interventions implemented in all affected houses are projected to prevent 11% to 63% of the hospital admissions and 7% to 39% of the deaths attributable to wildfire particles. The fraction of the population with an admission attributable to wildfire smoke is small, thus, the costs of interventions in all homes far exceeds the economic benefits of reduced hospital admissions. However, the estimated economic value of the prevented deaths exceed or far exceed intervention costs for interventions that do not use portable air cleaners. For the interventions with portable air cleaner use, mortality-related economic benefits exceed intervention costs as long as the cost of the air cleaners, which have a multi-year life, are not attributed to the short wildfire period. Cost effectiveness is improved by intervening only in the homes of the elderly who experience most of the health effects of particles from wildfires. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ceftazidime dosing in the elderly: economic implications.
Vlasses, P H; Bastion, W A; Behal, R; Sirgo, M A
1993-01-01
This study evaluated the prevalence and resulting costs of ceftazidime dosing in excess of product labeling recommendations in elderly hospitalized patients. Ceftazidime is a beta-lactam antibiotic excreted via glomerular filtration. According to product labeling, ceftazidime dosing can frequently be decreased in the elderly because glomerular filtration declines with age. A multicenter, retrospective utilization audit involving 11 US academic medical centers examined 221 medical records of patients 65 years of age or older receiving ceftazidime (any brand, any indication). The creatinine clearance of each patient was estimated using the Cockcroft-Gault formula. Renal insufficiency, defined as an estimated creatinine clearance of less than 50 mL/min, was present in 111 of the patients (50 percent). Ceftazidime dosing in excess of product labeling recommendations was noted in 75 of those 111 (68 percent). The cost of excess ceftazidime dosing for those 75 patients (i.e., extra drug acquisition, preparation, administration) was $13,822.50. Although the dosage of ceftazidime required in a specific patient is based on many factors, ceftazidime is frequently overdosed in the elderly because renal function is not considered. Ceftazidime dose-adjustment in the elderly, based on the estimated creatinine clearance, can lead to cost savings. In the US, where hospital reimbursement by Medicare is based on diagnosis, institutions can realize direct cost savings.
8. DETAIL OF COMPUTER SCREEN AND CONTROL BOARDS: LEFT SCREEN ...
8. DETAIL OF COMPUTER SCREEN AND CONTROL BOARDS: LEFT SCREEN TRACKS RESIDUAL CHLORINE; INDICATES AMOUNT OF SUNLIGHT WHICH ENABLES OPERATOR TO ESTIMATE NEEDED CHLORINE; CENTER SCREEN SHOWS TURNOUT STRUCTURES; RIGHT SCREEN SHOWS INDICATORS OF ALUMINUM SULFATE TANK FARM. - F. E. Weymouth Filtration Plant, 700 North Moreno Avenue, La Verne, Los Angeles County, CA
NASA Astrophysics Data System (ADS)
Dai, Z.; Wolfsberg, A. V.; Zhu, L.; Reimus, P. W.
2017-12-01
Colloids have the potential to enhance mobility of strongly sorbing radionuclide contaminants in fractured rocks at underground nuclear test sites. This study presents an experimental and numerical investigation of colloid-facilitated plutonium reactive transport in fractured porous media for identifying plutonium sorption/filtration processes. The transport parameters for dispersion, diffusion, sorption, and filtration are estimated with inverse modeling for minimizing the least squares objective function of multicomponent concentration data from multiple transport experiments with the Shuffled Complex Evolution Metropolis (SCEM). Capitalizing on an unplanned experimental artifact that led to colloid formation and migration, we adopt a stepwise strategy to first interpret the data from each experiment separately and then to incorporate multiple experiments simultaneously to identify a suite of plutonium-colloid transport processes. Nonequilibrium or kinetic attachment and detachment of plutonium-colloid in fractures was clearly demonstrated and captured in the inverted modeling parameters along with estimates of the source plutonium fraction that formed plutonium-colloids. The results from this study provide valuable insights for understanding the transport mechanisms and environmental impacts of plutonium in fractured formations and groundwater aquifers.
Mende, Christian W; Giles, Thomas D; Bharucha, David B; Ferguson, William G; Mallick, Madhuja; Patel, Mehul D
2017-06-01
Antihypertensive efficacy of single-pill combinations (SPCs) consisting of a β 1 -selective adrenergic blocker with vasodilatory properties via β 3 -agonism (nebivolol) and an angiotensin II receptor blocker (valsartan) was demonstrated in an 8-week phase 3 trial (NCT01508026). In this post hoc analysis, seated blood pressure, heart rate, 24-hour ambulatory blood pressure monitoring, plasma aldosterone, estimated glomerular filtration rate, and safety measures were assessed in obese (body mass index >32 kg/m 2 ; n=1823) and nonobese (body mass index <27 kg/m 2 ; n=847) adults with hypertension (stage I or II) treated with nebivolol-valsartan SPCs, nebivolol or valsartan monotherapy, or placebo. At week 8, reductions from baseline in blood pressure and ambulatory blood pressure monitoring were greater with SPCs and most nebivolol and valsartan monotherapy doses vs placebo regardless of obesity status. Aldosterone declined with all active treatments and estimated glomerular filtration rate remained steady. The nebivolol-valsartan 5/80 mg/d SPC was efficacious regardless of degree of obesity. © 2017 The Authors. The Journal of Clinical Hypertension Published by Wiley Periodicals, Inc.
Takenaka, Tsuneo; Kishimoto, Miyako; Ohta, Mari; Tomonaga, Osamu; Suzuki, Hiromichi
2017-05-01
The effects of sodium-glucose co-transporter type 2 inhibitors on home blood pressure were examined in type 2 diabetes with nephropathy. The patients with diabetic nephropathy were screened from medical records in our hospitals. Among them, 52 patients who measured home blood pressure and started to take sodium-glucose co-transporter type 2 inhibitors were selected. Clinical parameters including estimated glomerular filtration rate, albuminuria and home blood pressure for 6 months were analysed. Sodium-glucose co-transporter type 2 inhibitors (luseogliflozin 5 mg/day or canagliflozin 100 mg/day) reduced body weight, HbA1c, albuminuria, estimated glomerular filtration rate and office blood pressure. Although sodium-glucose co-transporter type 2 inhibitors did not alter morning blood pressure, it reduced evening systolic blood pressure. Regression analyses revealed that decreases in evening blood pressure predicted decrements in albuminuria. The present data suggest that sodium-glucose co-transporter type 2 inhibitors suppress sodium overload during daytime to reduce evening blood pressure and albuminuria.
Osugi, Naohiro; Suzuki, Susumu; Ishii, Hideki; Yasuda, Yoshinari; Shibata, Yohei; Tatami, Yosuke; Ota, Tomoyuki; Kawamura, Yoshihiro; Okumura, Satoshi; Tanaka, Akihito; Inoue, Yosuke; Matsuo, Seiichi; Murohara, Toyoaki
2014-07-01
Albuminuria has traditionally been associated with an elevated risk of cardiovascular events. However, few studies have examined the potential relation between albuminuria and periprocedural risk in percutaneous coronary intervention (PCI). The aim of this study was to evaluate the impact of albuminuria on the incidence of periprocedural myocardial injury (PMI) in patients who underwent PCI. The study included 252 consecutive patients who underwent PCI. The incidence of PMI was significantly higher in patients with albuminuria than in those with normoalbuminuria (31.9% vs 43.3%, respectively, p = 0.014). Even after adjustment for confounders, the presence of albuminuria predicted PMI (odds ratio 2.07, 95% confidence interval 1.08 to 3.97, p = 0.029). Furthermore, patients with albuminuria and preserved estimated glomerular filtration rate had a 4.2-fold higher risk for PMI than did patients with normoalbuminuria and preserved estimated glomerular filtration rate. In conclusion, albuminuria was a strong predictor of PMI in patients who underwent PCI. Copyright © 2014 Elsevier Inc. All rights reserved.
Wang, Zhen; Yuan, Xinxin; Cong, Shan; Chen, Zhigang; Li, Qingwen; Geng, Fengxia; Zhao, Zhigang
2018-05-02
Air pollution is one of the most serious issues affecting the world today. Instead of expensive and energy-intensive air filtering devices, a fiber-based transparent air filter coated on a window screen is seen as one of the state-of-the-art filtration technologies to combat the seriously growing problem, delivering the advantages of simplicity, convenience, and high filtering efficiency. However, such a window screen is currently limited to particulate matter (PM) filtration and ineffective with other air pollutants. Here, we report the use of a newfangled type of color-changing fibers, porous Prussian blue analogues (CuHCF)/polymer composite microfibers, for transparent window screens toward air pollutant filtration. To increase pollution filtration, pores and dimples are purposely introduced to the fibers using binary solvent systems through a nonsolvent-induced phase separation mechanism. Such composite microfibers overcome some of the limitations of those previously used fibers and could simultaneously capture PM 2.5 , PM 10 , and NH 3 with high efficiency. More interestingly, a distinct color change is observed upon exposure to air pollutants in such window screens, which provides multifunctional capability of simultaneous pollutant capture and naked eye screening of the pollutant amount. Specifically, in the case of long-term exposure to low-concentration NH 3 , the symbol displayed in such window screens changes from yellow color to brown and the coloration rate is directly controlled by the NH 3 concentration, which may serve as a careful reminder for those people who are repeatedly exposed to low-concentration ammonia gas (referred to as chronic poisoning). In contrast, after short-term exposure to a high concentration of ammonia gas, the yellow symbol immediately becomes blackened, which provides timely information about the risk of acute ammonia poisoning or even ammonia explosion. Further spectroscopic results show that the chromatic behaviors in response to different concentrations of NH 3 are fundamentally different, which is related to the different locations of ammonia in the lattice of CuHCF, either in its interstitial sites or at the Fe(CN) 6 vacancy sites, largely distinguished by the absence or presence of atmospheric moisture.
Bentahir, Mostafa; Laduron, Frederic; Irenge, Leonid; Ambroise, Jérôme; Gala, Jean-Luc
2014-01-01
Separating CBRN mixed samples that contain both chemical and biological warfare agents (CB mixed sample) in liquid and solid matrices remains a very challenging issue. Parameters were set up to assess the performance of a simple filtration-based method first optimized on separate C- and B-agents, and then assessed on a model of CB mixed sample. In this model, MS2 bacteriophage, Autographa californica nuclear polyhedrosis baculovirus (AcNPV), Bacillus atrophaeus and Bacillus subtilis spores were used as biological agent simulants whereas ethyl methylphosphonic acid (EMPA) and pinacolyl methylphophonic acid (PMPA) were used as VX and soman (GD) nerve agent surrogates, respectively. Nanoseparation centrifugal devices with various pore size cut-off (30 kD up to 0.45 µm) and three RNA extraction methods (Invisorb, EZ1 and Nuclisens) were compared. RNA (MS2) and DNA (AcNPV) quantification was carried out by means of specific and sensitive quantitative real-time PCRs (qPCR). Liquid chromatography coupled to time-of-flight mass spectrometry (LC/TOFMS) methods was used for quantifying EMPA and PMPA. Culture methods and qPCR demonstrated that membranes with a 30 kD cut-off retain more than 99.99% of biological agents (MS2, AcNPV, Bacillus Atrophaeus and Bacillus subtilis spores) tested separately. A rapid and reliable separation of CB mixed sample models (MS2/PEG-400 and MS2/EMPA/PMPA) contained in simple liquid or complex matrices such as sand and soil was also successfully achieved on a 30 kD filter with more than 99.99% retention of MS2 on the filter membrane, and up to 99% of PEG-400, EMPA and PMPA recovery in the filtrate. The whole separation process turnaround-time (TAT) was less than 10 minutes. The filtration method appears to be rapid, versatile and extremely efficient. The separation method developed in this work constitutes therefore a useful model for further evaluating and comparing additional separation alternative procedures for a safe handling and preparation of CB mixed samples. PMID:24505375
Numerical investigation of adhesion effects on solid particles filtration efficiency
NASA Astrophysics Data System (ADS)
Shaffee, Amira; Luckham, Paul; Matar, Omar K.
2017-11-01
Our work investigate the effectiveness of particle filtration process, in particular using a fully-coupled Computational Fluid Dynamics (CFD) and Discrete Element Method (DEM) approach involving poly-dispersed, adhesive solid particles. We found that an increase in particle adhesion reduces solid production through the opening of a wire-wrap type filter. Over time, as particle agglomerates continuously deposit on top of the filter, layer upon layer of particles is built on top of the filter, forming a particle pack. It is observed that with increasing particle adhesion, the pack height build up also increases and hence decreases the average particle volume fraction of the pack. This trend suggests higher porosity and looser packing of solid particles within the pack with increased adhesion. Furthermore, we found that the pressure drop for adhesive case is lower compared to non-adhesive case. Our results suggest agglomerating solid particles has beneficial effects on particle filtration. One important application of these findings is towards designing and optimizing sand control process for a hydrocarbon well with excessive sand production which is major challenge in oil and gas industry. Funding from PETRONAS and RAEng UK for Research Chair (OKM) gratefully acknowledged.
GPU-based cloud service for Smith-Waterman algorithm using frequency distance filtration scheme.
Lee, Sheng-Ta; Lin, Chun-Yuan; Hung, Che Lun
2013-01-01
As the conventional means of analyzing the similarity between a query sequence and database sequences, the Smith-Waterman algorithm is feasible for a database search owing to its high sensitivity. However, this algorithm is still quite time consuming. CUDA programming can improve computations efficiently by using the computational power of massive computing hardware as graphics processing units (GPUs). This work presents a novel Smith-Waterman algorithm with a frequency-based filtration method on GPUs rather than merely accelerating the comparisons yet expending computational resources to handle such unnecessary comparisons. A user friendly interface is also designed for potential cloud server applications with GPUs. Additionally, two data sets, H1N1 protein sequences (query sequence set) and human protein database (database set), are selected, followed by a comparison of CUDA-SW and CUDA-SW with the filtration method, referred to herein as CUDA-SWf. Experimental results indicate that reducing unnecessary sequence alignments can improve the computational time by up to 41%. Importantly, by using CUDA-SWf as a cloud service, this application can be accessed from any computing environment of a device with an Internet connection without time constraints.
Filter feeding mechanics of Hypophthalmichthys molitrix regarding porous gill rakers
NASA Astrophysics Data System (ADS)
Palumbo, David; Bulusu, Kartik V.; Cohen, Karly; Hernandez, Particia; Leftwich, Megan C.; Plesniak, Michael W.
2017-11-01
The silver carp (Hypophthalmichthys molitrix) is a filter-feeding fish known to feed upon algal-growth in lakes, rivers, and aquacultures. The filter-feeding process centers on sponge-like membranes located in the carp's pharynx supported by fused gill rakers (GRs), which can efficiently strain suspended food particles as small as 4 µm without clogging. Guided by the anatomy of the silver carp, scanning electron microscope (SEM) images of GRs, and video of the silver carp feeding, we have hypothesized that the filtration mechanism involves a pump-based biological function to capture food particles within the GRs. Dye visualization experiments were performed on a silver carp cadaver head, an excised GR sample, and on a scaled GR in vitro model - the Artificial Gill Raker (AGR). Measurements are performed for the AGR using laser Doppler velocimetry (LDV) and penetration pressure monitoring with a biologically-inspired pumping mechanism. The role of mucus in the retention and capture of food particles has also been explored through rheological measurements, and further experimentation is planned. Our motivation stems from the potential to develop bioinspired industrial-scale filtration technologies ranging from wastewater treatment to filtration in the food industry. supported by GW Center for Biomimetics and Bioinspired Engineering.
The cell engineering construction and function evaluation of multi-layer biochip dialyzer.
Zhu, Wen; Li, Jiwei; Liu, Jianfeng
2013-10-01
We report the fabrication and function evaluation of multi-layer biochip dialyzer. Such device may potentially be applied to the wearable hemodialysis systems. By merging the advantages of microfluidic chip technology with cell engineering, both functions of glomerular filtration and renal tubule physiological activity are integrated in the same device. This device is designed into a laminated structure, in which the chip number of the superimposed layer can be arbitrarily tailored in accordance with the requirements of dialysis capacity. We propose that such structure can overcome the obstacles of large size and detached structure of the traditional hollow fiber dialyzer. To construct this multilayer biochips dialyzer, two types of dialyzer device with two-layered and six-layered chips are assembled, respectively. Cell adhesion and proliferation on three different dialysis membrane materials under static and dynamic conditions are investigated and compared. The filtration capability, re-absorption function and excrete ammonia function of the resulting multi-layer biochip dialyzer are evaluated. The results reveal that the constructed device can perform higher filtration efficiency and also play a role of renal tubule. This methodology may be useful in developing "scaling down" artificial kidneys that can act as wearable or even implantable hemodialysis systems.
Zhao, Yi-Fan; Zhang, Pei-Bin; Sun, Jian; Liu, Cui-Jing; Yi, Zhuan; Zhu, Li-Ping; Xu, You-Yi
2015-06-15
Here we describe the development of versatile antifouling polyethersulfone (PES) filtration membranes modified via surface grafting of zwitterionic polymers from a reactive amphiphilic copolymer additive. Amphiphilic polyethersulfone-block-poly(2-hydroxyethyl methacrylate) (PES-b-PHEMA) was beforehand designed and used as the blending additive of PES membranes prepared by phase inversion technique. The surface enriched PHEMA blocks on membrane surface acted as an anchor to immobilize the initiating site. Poly(sulfobetaine methacrylate) (PSBMA) were subsequently grafted onto the PES blend membranes by surface-initiated atom transfer radical polymerization (SI-ATRP). The analysis of surface chemistry confirmed the successful grafting of zwitterionic PSBMA brushes on PES membrane surface. The resulted PES-g-PSBMA membranes were capable of separating proteins from protein solution and oil from oil/water emulsion efficiently. Furthermore, the modified membranes showed high hydrophilicity and strongly antifouling properties due to the incorporation of well-defined PSBMA layer. In addition, the PES-g-PSBMA membranes exhibited excellent blood compatibility and durability during the washing process. The developed antifouling PES membranes are versatile and can find their applications in protein filtration, blood purification and oil/water separation, etc. Copyright © 2015 Elsevier Inc. All rights reserved.
Highly Efficient Large-Scale Lentiviral Vector Concentration by Tandem Tangential Flow Filtration
Cooper, Aaron R.; Patel, Sanjeet; Senadheera, Shantha; Plath, Kathrin; Kohn, Donald B.; Hollis, Roger P.
2014-01-01
Large-scale lentiviral vector (LV) concentration can be inefficient and time consuming, often involving multiple rounds of filtration and centrifugation. This report describes a simpler method using two tangential flow filtration (TFF) steps to concentrate liter-scale volumes of LV supernatant, achieving in excess of 2000-fold concentration in less than 3 hours with very high recovery (>97%). Large volumes of LV supernatant can be produced easily through the use of multi-layer flasks, each having 1720 cm2 surface area and producing ~560 mL of supernatant per flask. Combining the use of such flasks and TFF greatly simplifies large-scale production of LV. As a demonstration, the method is used to produce a very high titer LV (>1010 TU/mL) and transduce primary human CD34+ hematopoietic stem/progenitor cells at high final vector concentrations with no overt toxicity. A complex LV (STEMCCA) for induced pluripotent stem cell generation is also concentrated from low initial titer and used to transduce and reprogram primary human fibroblasts with no overt toxicity. Additionally, a generalized and simple multiplexed real- time PCR assay is described for lentiviral vector titer and copy number determination. PMID:21784103
Zamyadi, Arash; Dorner, Sarah; Sauvé, Sébastien; Ellis, Donald; Bolduc, Anouka; Bastien, Christian; Prévost, Michèle
2013-05-15
Accumulation and breakthrough of several potentially toxic cyanobacterial species within drinking water treatment plants (DWTP) have been reported recently. The objectives of this project were to test the efficiency of different treatment barriers in cyanobacterial removal. Upon observation of cyanobacterial blooms, intensive sampling was conducted inside a full scale DWTP at raw water, clarification, filtration and oxidation processes. Samples were taken for microscopic speciation/enumeration and microcystins analysis. Total cyanobacteria cell numbers exceeded World Health Organisation and local alert levels in raw water (6,90,000 cells/mL). Extensive accumulation of cyanobacteria species in sludge beds and filters, and interruption of treatment were observed. Aphanizomenon cells were poorly coagulated and they were not trapped efficiently in the sludge. It was also demonstrated that Aphanizomenon cells passed through and were not retained over the filter. However, Microcystis, Anabaena, and Pseudanabaena cells were adequately removed by clarification and filtration processes. The breakthrough of non toxic cyanobacterial cells into DWTPs could also result in severe treatment disruption leading to plant shutdown. Application of intervention threshold values restricted to raw water does not take into consideration the major long term accumulation of potentially toxic cells in the sludge and the risk of toxins release. Thus, a sampling regime inside the plant adapted to cyanobacterial occurrence and intensity is recommended. Copyright © 2013 Elsevier Ltd. All rights reserved.
Enhancement of CNT-based filters efficiency by ion beam irradiation
NASA Astrophysics Data System (ADS)
Elsehly, Emad M.; Chechenin, N. G.; Makunin, A. V.; Shemukhin, A. A.; Motaweh, H. A.
2018-05-01
It is shown in the report that disorder produced by ion beam irradiation can enhance the functionality of the carbon nanotubes. The filters of pressed multiwalled carbon nanotubes (MWNTs) were irradiated by He+ ions of the energy E = 80 keV with the fluence 2 × 1016 ion/cm2. The removal of manganese from aqueous solutions by using pristine and ion beam irradiated MWNTs filters was studied as a function of pH, initial concentration of manganese in aqueous solution, MWNT mass and contact time. The filters before and after filtration were characterized by Raman (RS) and energy dispersive X-ray spectroscopy (EDS) techniques to investigate the deposition content in the filter and defect formation in the MWNTs. The irradiated samples showed an enhancement of removal efficiency of manganese up to 97.5% for 10 ppm Mn concentration, suggesting that irradiated MWNT filter is a better Mn adsorbent from aqueous solutions than the pristine one. Radiation-induced chemical functionalization of MWNTs due to ion beam irradiation, suggesting that complexation between the irradiated MWNTs and manganese ions is another mechanism. This conclusion is supported by EDS and RS and is correlated with a larger disorder in the irradiated samples as follows from RS. The study demonstrates that ion beam irradiation is a promising tool to enhance the filtration efficiency of MWNT filters.
NASA Technical Reports Server (NTRS)
Green, Robert D.; Agui, Juan H.; Vijayakumar, R.
2017-01-01
The air revitalization system aboard the International Space Station (ISS) provides the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation due to the microgravity environment in Low Earth Orbit (LEO). The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) media filters deployed at multiple locations in each U.S. Segment module; these filters are referred to as Bacterial Filter Elements, or BFEs. These filters see a replacement interval, as part of maintenance, of 2-5 years dependent on location in the ISS. In this work, we present particulate removal efficiency, pressure drop, and leak test results for a sample set of 8 BFEs returned from the ISS after filter replacement. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS beyond 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.
Shivaraju, H Puttaiah; Egumbo, Henok; Madhusudan, P; Anil Kumar, K M; Midhun, G
2018-02-01
Affordable clay-based ceramic filters with multifunctional properties were prepared using low-cost and active ingredients. The characterization results clearly revealed well crystallinity, structural elucidation, extensive porosity, higher surface area, higher stability, and durability which apparently enhance the treatment efficiency. The filtration rates of ceramic filter were evaluated under gravity and the results obtained were compared with a typical gravity slow sand filter (GSSF). All ceramic filters showed significant filtration rates of about 50-180 m/h, which is comparatively higher than the typical GSSF. Further, purification efficiency of clay-based ceramic filters was evaluated by considering important drinking water parameters and contaminants. A significant removal potential was achieved by the clay-based ceramic filter with 25% and 30% activated carbon along with active agents. Desired drinking water quality parameters were achieved by potential removal of nitrite (98.5%), nitrate (80.5%), total dissolved solids (62%), total hardness (55%), total organic pollutants (89%), and pathogenic microorganisms (100%) using ceramic filters within a short duration. The remarkable purification and disinfection efficiencies were attributed to the extensive porosity (0.202 cm 3 g -1 ), surface area (124.61 m 2 g -1 ), stability, and presence of active nanoparticles such as Cu, TiO 2 , and Ag within the porous matrix of the ceramic filter.
Modeling the resiliency of energy-efficient retrofits in low-income multifamily housing.
Underhill, L J; Fabian, M P; Vermeer, K; Sandel, M; Adamkiewicz, G; Leibler, J H; Levy, J I
2018-05-01
Residential energy efficiency and ventilation retrofits (eg, building weatherization, local exhaust ventilation, HVAC filtration) can influence indoor air quality (IAQ) and occupant health, but these measures' impact varies by occupant activity. In this study, we used the multizone airflow and IAQ analysis program CONTAM to simulate the impacts of energy retrofits on indoor concentrations of PM 2.5 and NO 2 in a low-income multifamily housing complex in Boston, Massachusetts (USA). We evaluated the differential impact of residential activities, such as low- and high-emission cooking, cigarette smoking, and window opening, on IAQ across two seasons. We found that a comprehensive package of energy and ventilation retrofits was resilient to a range of occupant activities, while less holistic approaches without ventilation improvements led to increases in indoor PM 2.5 or NO 2 for some populations. In general, homes with simulated concentration increases included those with heavy cooking and no local exhaust ventilation, and smoking homes without HVAC filtration. Our analytical framework can be used to identify energy-efficient home interventions with indoor retrofit resiliency (ie, those that provide IAQ benefits regardless of occupant activity), as well as less resilient retrofits that can be coupled with behavioral interventions (eg, smoking cessation) to provide cost-effective, widespread benefits. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Al-Sabi, M N S; Gad, J A; Riber, U; Kurtzhals, J A L; Enemark, H L
2015-09-01
To develop a filtration unit for efficient recovery of waterborne Cryptosporidium oocysts and Giardia cysts ((oo-)cysts) in drinking water. This unit utilizes a metallic filter and an ultrasound transducer for eluting (oo-)cysts, with a fixed retentate backwash volume; approx. 400 μl. Changes in the viability was evaluated by seeding wild type (oo-)cysts (1 × 10(4)) followed by sonication for 5, 10, 20 or 40 s (five replicates for each period). Flow cytometry analysis showed negligible increase in the mortality of (oo-)cysts exposed to 5-10 s of sonication. Recovery rate was assessed by seeding ColorSeed(™) (10 replicates) into the filter unit followed by air backwash to a glass slide and counting of (oo-)cysts by epifluorescent microscopy. High recovery rates (mean ± SD) were found: 84·9% ± 4·8 for Giardia cysts and 70% ± 6·5 for Cryptosporidium oocysts. DNA of seeded wild type (oo-)cysts (1 × 10(2); 10 replicates) was successfully amplified using real-time PCR. The use of a metallic filter, sonication and 'air backwash' were key factors for creating a highly efficient system for recovery of apparently undamaged protozoa. This reagent-less system can be used for monitoring of parasite contamination in drinking water. © 2015 The Society for Applied Microbiology.
Haifler, Miki; Ristau, Benjamin T; Higgins, Andrew M; Smaldone, Marc C; Kutikov, Alexander; Zisman, Amnon; Uzzo, Robert G
2017-09-20
We sought to externally validate a mathematical formula for tumor contact surface area as a predictor of postoperative renal function in patients undergoing partial nephrectomy for renal cell carcinoma. We queried a prospectively maintained kidney cancer database for patients who underwent partial nephrectomy between 2014 and 2016. Contact surface area was calculated using data obtained from preoperative cross-sectional imaging. The correlation between contact surface area and perioperative variables was examined. The correlation between postoperative renal functional outcomes, contact surface area and the R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines and tumor touches main renal artery or vein) nephrometry score was also assessed. A total of 257 patients who underwent partial nephrectomy had sufficient data to enter the study. Median contact surface area was 14.5 cm 2 (IQR 6.2-36) and the median nephrometry score was 9 (IQR 7-10). Spearman correlation analysis showed that contact surface area correlated with estimated blood loss (r s = 0.42, p <0.001), length of stay (r s = 0.18, p = 0.005), and percent and absolute change in the estimated glomerular filtration rate (r s = -0.77 and -0.78, respectively, each p <0.001). On multivariable analysis contact surface area and nephrometry score were independent predictors of the absolute change in the estimated glomerular filtration rate (each p <0.001). ROC curve analysis revealed that contact surface area was a better predictor of a greater than 20% postoperative decline in the estimated glomerular filtration rate compared with the nephrometry score (AUC 0.94 vs 0.80). Contact surface area correlated with the change in postoperative renal function after partial nephrectomy. It can be used in conjunction with the nephrometry score to counsel patients about the risk of renal functional decline after partial nephrectomy. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu Zhaohuan; Dong Ruobing; Nelson, Richard P.
By carrying out two-dimensional two-fluid global simulations, we have studied the response of dust to gap formation by a single planet in the gaseous component of a protoplanetary disk-the so-called dust filtration mechanism. We have found that a gap opened by a giant planet at 20 AU in an {alpha} = 0.01, M-dot =10{sup -8} M{sub Sun} yr{sup -1} disk can effectively stop dust particles larger than 0.1 mm drifting inward, leaving a submillimeter (submm) dust cavity/hole. However, smaller particles are difficult to filter by a gap induced by a several M{sub J} planet due to (1) dust diffusion andmore » (2) a high gas accretion velocity at the gap edge. Based on these simulations, an analytic model is derived to understand what size particles can be filtered by the planet-induced gap edge. We show that a dimensionless parameter T{sub s} /{alpha}, which is the ratio between the dimensionless dust stopping time and the disk viscosity parameter, is important for the dust filtration process. Finally, with our updated understanding of dust filtration, we have computed Monte Carlo radiative transfer models with variable dust size distributions to generate the spectral energy distributions of disks with gaps. By comparing with transitional disk observations (e.g., GM Aur), we have found that dust filtration alone has difficulties depleting small particles sufficiently to explain the near-IR deficit of moderate M-dot transitional disks, except under some extreme circumstances. The scenario of gap opening by multiple planets studied previously suffers the same difficulty. One possible solution is to invoke both dust filtration and dust growth in the inner disk. In this scenario, a planet-induced gap filters large dust particles in the disk, and the remaining small dust particles passing to the inner disk can grow efficiently without replenishment from fragmentation of large grains. Predictions for ALMA have also been made based on all these scenarios. We conclude that dust filtration with planet(s) in the disk is a promising mechanism to explain submm observations of transitional disks but it may need to be combined with other processes (e.g., dust growth) to explain the near-IR deficit of some systems.« less
Jung, Jae Hee; Hwang, Gi Byoung; Lee, Jung Eun; Bae, Gwi Nam
2011-08-16
Carbon nanotubes (CNTs) have been widely used in a variety of applications because of their unique structure and excellent mechanical and electrical properties. Additionally, silver (Ag) nanoparticles exhibit broad-spectrum biocidal activity toward many different bacteria, fungi, and viruses. In this study, we prepared Ag-coated CNT hybrid nanoparticles (Ag/CNTs) using aerosol nebulization and thermal evaporation/condensation processes and tested their usefulness for antimicrobial air filtration. Droplets were generated from a CNT suspension using a six-jet collison nebulizer, passed through a diffusion dryer to remove moisture, and entered a thermal tube furnace where silver nanoparticles were generated by thermal evaporation/condensation at ∼980 °C in a nitrogen atmosphere. The CNT and Ag nanoparticle aerosols mixed together and attached to each other, forming Ag/CNTs. For physicochemical characterization, the Ag/CNTs were introduced into a scanning mobility particle sizer (SMPS) for size distribution measurements and were sampled by the nanoparticle sampler for morphological and elemental analyses. For antimicrobial air filtration applications, the airborne Ag/CNT particles generated were deposited continuously onto an air filter medium. Physical characteristics (fiber morphology, pressure drop, and filtration efficiency) and biological characteristics (antimicrobial tests against Staphylococcus epidermidis and Escherichia coli bioaerosols) were evaluated. Real-time SMPS and transmission electron microscopy (TEM) data showed that Ag nanoparticles that were <20 nm in diameter were homogeneously dispersed and adhered strongly to the CNT surfaces. Because of the attachment of Ag nanoparticles onto the CNT surfaces, the total particle surface area concentration measured by a nanoparticle surface area monitor (NSAM) was lower than the summation of each Ag nanoparticle and CNT generated. When Ag/CNTs were deposited on the surface of an air filter medium, the antimicrobial activity against test bacterial bioaerosols was enhanced, compared with the deposition of CNTs or Ag nanoparticles alone, whereas the filter pressure drop and bioaerosol filtration efficiency were similar to those of CNT deposition only. At a residence time of 2 h, the relative microbial viabilities of gram-positive S. epidermidis were ∼32, 13, 5, and 0.9% on the control, CNT-, Ag nanoparticle-, and Ag/CNT-deposited filters, respectively, and those of gram-negative E. coli were 13, 2.1, 0.4, and 0.1% on the control, CNTs, Ag nanoparticles, and Ag/CNTs, respectively. These Ag/CNT hybrid nanoparticles may be useful for applications in biomedical devices and antibacterial control systems.
Moyer, E S; Bergman, M S
2000-08-01
The effects of intermittently loading small masses of sodium chloride aerosol on the filtration efficiency of N-95 filtering facepiece respirators was investigated. The National Institute for Occupational Safety and Health (NIOSH) certifies that N-95 respirators must provide at least 95 percent filtration efficiency against a sodium chloride aerosol challenge as per the respirator certification (42 CFR 84) test criteria. N-95 respirators are specified for protection against solid and water-based particulates (i.e., non-oil aerosols). New N-95 respirators from three different manufacturers were loaded with 5 +/- 1 mg of sodium chloride aerosol one day a week, over a period of weeks. Aerosol loading and penetration measurements were performed using the TSI 8130 Filter Tester. Respirators were stored uncovered on an office desktop outside the laboratory. To investigate environmental and temporal effects of filters being stored without sodium chloride exposure, control respirators were stored on the desk for various lengths of time before being initiated into weekly testing. For all manufacturers' respirators, the controls showed similar initial penetrations on their day of initiation (day zero) to those of the study samples on day zero. As the controls were tested weekly, they showed similar degradation rates to those of the study samples. Results show that some of the manufacturers' models had penetrations of greater than 5 percent when intermittently exposed to sodium chloride aerosol. It is concluded that intermittent, low-level sodium chloride aerosol loading of N-95 respirators has a degrading effect on filter efficiency. This reduction in filter efficiency was not accompanied by a significant increase in breathing resistance that would signal the user that the filter needs to be replaced. Furthermore, it was noted that the effect of room storage time prior to initial exposure was much less significant.
Current use of equations for estimating glomerular filtration rate in Spanish laboratories.
Gràcia-Garcia, Sílvia; Montañés-Bermúdez, Rosario; Morales-García, Luis J; Díez-de Los Ríos, M José; Jiménez-García, Juan Á; Macías-Blanco, Carlos; Martínez-López, Rosalina; Ruiz-Altarejos, Joaquín; Ruiz-Martín, Guadalupe; Sanz-Hernández, Sonia; Ventura-Pedret, Salvador
2012-07-17
In 2006 the Spanish Society of Clinical Biochemistry and Molecular Pathology (SEQC) and the Spanish Society of Nephrology (S.E.N.) developed a consensus document in order to facilitate the diagnosis and monitoring of chronic kidney disease with the incorporation of equations for estimating glomerular filtration rate (eGFR) into laboratory reports. The current national prevalence of eGFR reporting and the degree of adherence to these recommendations among clinical laboratories is unknown. We administered a national survey in 2010-11 to Spanish clinical laboratories. The survey was through e-mail or telephone to laboratories that participated in the SEQC’s Programme for External Quality Assurance, included in the National Hospitals Catalogue 2010, including both primary care and private laboratories. A total of 281 laboratories answered to the survey. Of these, 88.2% reported on the eGFR, with 61.9% reporting on the MDRD equation and 31.6% using the MDRD-IDMS equation. A total of 42.5% of laboratories always reported serum creatinine values, and other variables only when specifically requested. Regarding the way results were presented, 46.2% of laboratories reported the exact numerical value only when the filtration rate was below 60mL/min/1.73m2, while 50.6% reported all values regardless. In 56.3% of the cases reporting eGFR, an interpretive commentary of it was enclosed. Although a high percentage of Spanish laboratories have added eGFR in their reports, this metric is not universally used. Moreover, some aspects, such as the equation used and the correct expression of eGFR results, should be improved.
Rossignol, Patrick; Dobre, Daniela; McMurray, John J V; Swedberg, Karl; Krum, Henry; van Veldhuisen, Dirk J; Shi, Harry; Messig, Michael; Vincent, John; Girerd, Nicolas; Bakris, George; Pitt, Bertram; Zannad, Faiez
2014-01-01
Mineralocorticoid receptor antagonists improve outcomes in patients with systolic heart failure but may induce worsening of renal function (WRF) and hyperkalemia (HK). We assessed the risk factors for mineralocorticoid receptor antagonist-related WRF and for HK, as well as the association between HK and WRF with clinical outcomes in the Eplerenone in Mild Patients Hospitalization and Survival Study in Heart Failure (EMPHASIS-HF). Serial changes in estimated glomerular filtration rate and in serum potassium were available in 2737 patients during a median 21-month follow-up. HK variably defined as serum K>4.5, 5, or 5.5 mmol/L occurred in 74.7%, 32.5%, and 8.9% patients enrolled in EMPHASIS-HF, respectively. WRF defined as a decrease in estimated glomerular filtration rate>20% or >30% from baseline occurred in 27% and 14% of patients, respectively. Patients assigned eplerenone displayed modest and early but significant and persistent (1) rise in serum potassium and (2) reduction in estimated glomerular filtration rate when compared with those assigned placebo. In multivariate analyses, eplerenone was associated with a higher incidence of WRF and HK, which were interrelated and also associated with baseline patient characteristics (eg, age≥75 years, hypertension, diabetes mellitus, nonwhite race, ejection fraction<30%, and treatment with an antiarrythmics drug or loop diuretic). Eplerenone retained its survival benefits without any significant interaction with the association between HK>5.5 mmol/L only and WRF and worse outcomes. In patients with heart failure receiving optimal therapy, WRF and HK were more frequent when eplerenone was added, but their occurrence did not eliminate the survival benefit of eplerenone. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00232180.
Tsai, Ching-Wei; Grams, Morgan E.; Inker, Lesley A.; Coresh, Josef; Selvin, Elizabeth
2014-01-01
OBJECTIVE Serum cystatin C is an alternative to serum creatinine for estimating glomerular filtration rate (GFR), since cystatin C is less influenced by age and muscle mass. Among persons with diabetes, we compared the performance of GFR estimated using cystatin C (eGFRcys) with that using creatinine (eGFRcr) for the identification of reduced kidney function and its association with diabetes complications. RESEARCH DESIGN AND METHODS We analyzed data from adult participants from the 1999–2002 National Health and Nutrition Examination Survey with available cystatin C (N = 4,457). Kidney function was dichotomized as preserved (eGFR ≥60 mL/min/1.73 m2) or reduced (eGFR <60 mL/min/1.73 m2) using the 2012 Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) cystatin C and the 2009 CKD-EPI creatinine equations. RESULTS Among 778 persons with diabetes, the prevalence of reduced kidney function was 16.5% using eGFRcr and 22.0% using eGFRcys. More persons with diabetes were reclassified from preserved kidney function by eGFRcr to reduced kidney function by eGFRcys than persons without diabetes (odds ratio 3.1 [95% CI 1.9–4.9], P < 0.001). The associations between lower eGFR and higher prevalence of albuminuria, retinopathy, peripheral arterial disease, and coronary artery disease were robust regardless of filtration marker. Similarly, the risk of all-cause mortality increased with lower eGFRcr and eGFRcys. Only lower eGFRcys was significantly associated with cardiovascular mortality. CONCLUSIONS More persons with diabetes had reduced kidney function by eGFRcys than by eGFRcr, and lower eGFRcys was strongly associated with diabetes complications. Whether eGFRcys is superior to eGFRcr in approximating true kidney function in a diabetic population requires additional study. PMID:24271191
Skinner, Eila C; Fairey, Adrian S; Groshen, Susan; Daneshmand, Siamak; Cai, Jie; Miranda, Gus; Skinner, Donald G
2015-08-01
The need to prevent reflux in the construction of an orthotopic ileal neobladder is controversial. We designed the USC-STAR trial to determine whether the T-pouch neobladder that included an antireflux mechanism was superior to the Studer pouch in patients with bladder cancer undergoing radical cystectomy. This single center, randomized, controlled trial recruited patients with clinically nonmetastatic bladder cancer scheduled to undergo radical cystectomy with neobladder. Eligible patients were randomly assigned to undergo T-pouch or Studer ileal orthotopic neobladder. Treatment assignment was not masked. The primary end point was change in renal function from baseline to 3 years. The CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration) equation was used to calculate the estimated glomerular filtration rate. Between February 2002 and November 2009, 237 patients were randomly assigned to T-pouch ileal orthotopic neobladder and 247 to Studer ileal orthotopic neobladder. Baseline characteristics did not differ between the groups. Between baseline and 3 years the estimated glomerular filtration rate decreased by 6.4 ml/minute/1.73 m(2) in the Studer group and 6.6 ml/minute/1.73 m(2) in the T-pouch group (p=0.35). Multivariable analysis showed that type of ileal orthotopic neobladder was not independently associated with 3-year renal function (p=0.63). However, baseline estimated glomerular filtration rate, age and urinary tract obstruction were independently associated with 3-year decline in renal function. Cumulative risk of urinary tract infection and overall late complications were not different between the groups, but the T-pouch was associated with an increased risk of secondary diversion related surgeries. T-pouch ileal orthotopic neobladder with an antireflux mechanism did not prevent a moderate reduction in renal function observed at 3 years compared to the Studer pouch, but did result in an increase in diversion related secondary surgical procedures. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Association of Race With Mortality and Cardiovascular Events in a Large Cohort of US Veterans.
Kovesdy, Csaba P; Norris, Keith C; Boulware, L Ebony; Lu, Jun L; Ma, Jennie Z; Streja, Elani; Molnar, Miklos Z; Kalantar-Zadeh, Kamyar
2015-10-20
In the general population, blacks experience higher mortality than their white peers, attributed in part to their lower socioeconomic status, reduced access to care, and possibly intrinsic biological factors. Patients with kidney disease are a notable exception, among whom blacks experience lower mortality. It is unclear if similar differences affecting outcomes exist in patients with no kidney disease but with equal or similar access to health care. We compared all-cause mortality, incident coronary heart disease, and incident ischemic stroke using multivariable-adjusted Cox models in a nationwide cohort of 547 441 black and 2 525 525 white patients with baseline estimated glomerular filtration rate ≥ 60 mL·min⁻¹·1.73 m⁻² receiving care from the US Veterans Health Administration. In parallel analyses, we compared outcomes in black versus white individuals in the National Health and Nutrition Examination Survey (NHANES) 1999 to 2004. After multivariable adjustments in veterans, black race was associated with 24% lower all-cause mortality (adjusted hazard ratio, 0.76; 95% confidence interval, 0.75-0.77; P<0.001) and 37% lower incidence of coronary heart disease (adjusted hazard ratio, 0.63; 95% confidence interval, 0.62-0.65; P<0.001) but a similar incidence of ischemic stroke (adjusted hazard ratio, 0.99; 95% confidence interval, 0.97-1.01; P=0.3). Black race was associated with a 42% higher adjusted mortality among individuals with estimated glomerular filtration rate ≥ 60 mL·min⁻¹·1.73 m⁻² in NHANES (adjusted hazard ratio, 1.42; 95% confidence interval, 1.09-1.87). Black veterans with normal estimated glomerular filtration rate and equal access to healthcare have lower all-cause mortality and incidence of coronary heart disease and a similar incidence of ischemic stroke. These associations are in contrast to the higher mortality experienced by black individuals in the general US population. © 2015 American Heart Association, Inc.
Chronic Kidney Disease Is Associated With White Matter Hyperintensity Volume
Khatri, Minesh; Wright, Clinton B.; Nickolas, Thomas L.; Yoshita, Mitsuhiro; Paik, Myunghee C.; Kranwinkel, Grace; Sacco, Ralph L.; DeCarli, Charles
2010-01-01
Background and Purpose White matter hyperintensities have been associated with increased risk of stroke, cognitive decline, and dementia. Chronic kidney disease is a risk factor for vascular disease and has been associated with inflammation and endothelial dysfunction, which have been implicated in the pathogenesis of white matter hyperintensities. Few studies have explored the relationship between chronic kidney disease and white matter hyperintensities. Methods The Northern Manhattan Study is a prospective, community-based cohort of which a subset of stroke-free participants underwent MRIs. MRIs were analyzed quantitatively for white matter hyperintensities volume, which was log-transformed to yield a normal distribution (log-white matter hyperintensity volume). Kidney function was modeled using serum creatinine, the Cockcroft-Gault formula for creatinine clearance, and the Modification of Diet in Renal Disease formula for estimated glomerular filtration rate. Creatinine clearance and estimated glomerular filtration rate were trichotomized to 15 to 60 mL/min, 60 to 90 mL/min, and >90 mL/min (reference). Linear regression was used to measure the association between kidney function and log-white matter hyperintensity volume adjusting for age, gender, race–ethnicity, education, cardiac disease, diabetes, homocysteine, and hypertension. Results Baseline data were available on 615 subjects (mean age 70 years, 60% women, 18% whites, 21% blacks, 62% Hispanics). In multivariate analysis, creatinine clearance 15 to 60 mL/min was associated with increased log-white matter hyperintensity volume (β 0.322; 95% CI, 0.095 to 0.550) as was estimated glomerular filtration rate 15 to 60 mL/min (β 0.322; 95% CI, 0.080 to 0.564). Serum creatinine, per 1-mg/dL increase, was also positively associated with log-white matter hyperintensity volume (β 1.479; 95% CI, 1.067 to 2.050). Conclusions The association between moderate–severe chronic kidney disease and white matter hyperintensity volume highlights the growing importance of kidney disease as a possible determinant of cerebrovascular disease and/or as a marker of microangiopathy. PMID:17962588
Ascher, Simon B; Scherzer, Rebecca; Peralta, Carmen A; Tien, Phyllis C; Grunfeld, Carl; Estrella, Michelle M; Abraham, Alison; Gustafson, Deborah R; Nowicki, Marek; Sharma, Anjali; Cohen, Mardge H; Butch, Anthony W; Young, Mary A; Bennett, Michael R; Shlipak, Michael G
2017-02-01
Subclinical kidney disease is associated with developing hypertension in the general population, but data are lacking among HIV-infected people. We examined associations of kidney function and injury with incident hypertension in 823 HIV-infected and 267 HIV-uninfected women in the Women's Interagency HIV Study, a multicenter, prospective cohort of HIV-infected and uninfected women in the United States. Baseline kidney biomarkers included estimated glomerular filtration rate using cystatin C, urine albumin-to-creatinine ratio, and 7 urine biomarkers of tubular injury: α-1-microglobulin, interleukin-18, kidney injury molecule-1, neutrophil gelatinase-associated lipocalin, liver fatty acid-binding protein, N-acetyl-β-d-glucosaminidase, and α1-acid-glycoprotein. We used multivariable Poisson regression to evaluate associations of kidney biomarkers with incident hypertension, defined as 2 consecutive visits of antihypertensive medication use. During a median follow-up of 9.6 years, 288 HIV-infected women (35%) developed hypertension. Among the HIV-infected women, higher urine albumin-to-creatinine ratio was independently associated with incident hypertension (relative risk =1.13 per urine albumin-to-creatinine ratio doubling, 95% confidence interval, 1.07-1.20), as was lower estimated glomerular filtration rate (relative risk =1.10 per 10 mL/min/1.73 m 2 lower estimated glomerular filtration rate; 95% confidence interval, 1.04-1.17). No tubular injury and dysfunction biomarkers were independently associated with incident hypertension in HIV-infected women. In contrast, among the HIV-uninfected women, urine albumin-to-creatinine ratio was not associated with incident hypertension, whereas higher urine interleukin-18, α1-acid-glycoprotein, and N-acetyl-β-d-glucosaminidase levels were significantly associated with incident hypertension. These findings suggest that early glomerular injury and kidney dysfunction may be involved in the pathogenesis of hypertension in HIV-infected people. The associations of tubular markers with hypertension in HIV-uninfected women should be validated in other studies. © 2016 American Heart Association, Inc.
Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo
2017-06-01
To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P < 0.001 and r = 0.94, P < 0.001). The preoperative and postoperative split estimated glomerular filtration rate of the operated kidney showed a moderate correlation with split renal function (r = 0.39, P = 0.004 and r = 0.49, P < 0.001). The correlation between reductions in split renal function and split renal volume of the operated kidney (r = 0.87, P < 0.001) was stronger than that between split renal function and percent reduction in split estimated glomerular filtration rate (r = 0.64, P < 0.001). The split renal volume calculated using computed tomography-based renal volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.
Abumuaileq, Rami Riziq-Yousef; Abu-Assi, Emad; López-López, Andrea; Raposeiras-Roubin, Sergio; Rodríguez-Mañero, Moisés; Martínez-Sande, Luis; García-Seara, Francisco Javier; Fernandez-López, Xesus Alberte; González-Juanatey, Jose Ramón
2015-10-26
To compare the performance of the re-expressed Modification of Diet in Renal Disease equation vs the new Chronic Kidney Disease Epidemiology Collaboration equation in patients with non-valvular atrial fibrillation. We studied 911 consecutive patients with non-valvular atrial fibrillation on vitamin-K antagonist. The performance of the re-expressed Modification of Diet in Renal Disease equation vs the new Chronic Kidney Disease Epidemiology Collaboration equation in patients with non-valvular atrial fibrillation with respect to either a composite endpoint of major bleeding, thromboembolic events and all-cause mortality or each individual component of the composite endpoint was assessed using continuous and categorical ≥ 60, 59-30, and < 30 mL/min per 1.73 m(2) estimated glomerular filtration rate. During 10 ± 3 mo, the composite endpoint occurred in 98 (10.8%) patients: 30 patients developed major bleeding, 18 had thromboembolic events, and 60 died. The new equation provided lower prevalence of renal dysfunction < 60 mL/min per 1.73 m(2) (32.9%), compared with the re-expressed equation (34.1%). Estimated glomerular filtration rate from both equations was independent predictor of composite endpoint (HR = 0.98 and 0.97 for the re-expressed and the new equation, respectively; P < 0.0001) and all-cause mortality (HR = 0.98 for both equations, P < 0.01). Strong association with thromboembolic events was observed only when estimated glomerular filtration rate was < 30 mL/min per 1.73 m(2): HR is 5.1 for the re-expressed equation, and HR = 5.0 for the new equation. No significant association with major bleeding was observed for both equations. The new equation reduced the prevalence of renal dysfunction. Both equations performed similarly in predicting major adverse outcomes.
Lujambio, Inés; Sottolano, Mariana; Robaina, Sebastián; Carusso, Florencia; da Rosa, Alicia; Ríos, Ana Carina; Olascoaga, Alicia; Gadola, Liliana; Noboa, Oscar; Staessen, Jan A.; Boggia, José
2014-01-01
Background. Estimation of glomerular filtration rate (eGFR) from biomarkers has evolved and multiple equations are available to estimate renal function at bedside. Methods. In a random sample of 119 Uruguayans (54.5% women; 56.2 years (mean)), we used Bland and Altman's method and Cohen's kappa statistic to assess concordance on a continuous or categorical (eGFR < 60 versus ≥60 mL/min/1.73 m2) scale between eGFRcys (reference) and eGFR derived from serum creatinine according to the Modification of Diet in Renal Disease (eGFRmdrd) or the Chronic Kidney Disease Epidemiology Collaboration equations (eGFRepi) or from both serum cystatin C and creatinine (eGFRmix). Results. In all participants, eGFRmdrd, eGFRepi, and eGFRmix were, respectively, 9.7, 11.5, and 5.6 mL/min/1.73 m2 higher (P < 0.0001) than eGFRcys. The prevalence of eGFR <60 mL/min/1.73 m2 was the highest for eGFRcys (21.8%), intermediate for eGFRmix (11.8%), and the lowest for eGFRmdrd (5.9%) and eGFRepi (3.4%). Using eGFRcys as reference, we found only fair agreement with the equations based on creatinine (Cohen's kappa statistic 0.15 to 0.23). Conclusion. Using different equations we reached clinically significant differences in the estimation of renal function. eGFRcys provides lower estimates, resulting in higher prevalence of eGFR <60 mL/min/1.73 m2. PMID:25215234
N-SINK - reduction of waste water nitrogen load
NASA Astrophysics Data System (ADS)
Aalto, Sanni; Tiirola, Marja; Arvola, Lauri; Huotari, Jussi; Tulonen, Tiina; Rissanen, Antti; Nykänen, Hannu
2014-05-01
Protection of the Baltic Sea from eutrophication is one of the key topics in the European Union environmental policy. One of the main anthropogenic sources of nitrogen (N) loading into Baltic Sea are waste water treatment plants, which are currently capable in removing only 40-70% of N. European commission has obliged Finland and other Baltic states to reduce nitrate load, which would require high monetary investments on nitrate removal processes in treatment plants. In addition, forced denitrification in treatment plants would increase emissions of strong greenhouse gas N2O. In this project (LIFE12 FI/ENV/597 N-SINK) we will develop and demonstrate a novel economically feasible method for nitrogen removal using applied ecosystem services. As sediment is known to have enormous capacity to reduce nitrate to nitrogen gas through denitrification, we predict that spatial optimization of the waste water discharge would be an efficient way to reduce nitrate-based load in aquatic systems. A new sediment filtration approach, which will increase both the area and time that nitrified waste water will be in contact with the reducing microbes of the sediment, is tested. Compared to the currently implemented practice, where purified waste water is discharged though one-point outlet system, we expect that sediment filtration system will result in more efficient denitrification and decreased N load to aquatic system. We will conduct three full-scale demonstrations in the receiving water bodies of waste water treatment plants in Southern and Central Finland. The ecosystem effects of sediment filtration system will be monitored. Using the most advanced stable isotope techniques will allow us accurately measure denitrification and unfavoured DNRA (reduction of nitrite to ammonium) activity.
Wood dust particle and mass concentrations and filtration efficiency in sanding of wood materials.
Welling, Irma; Lehtimäki, Matti; Rautio, Sari; Lähde, Tero; Enbom, Seppo; Hynynen, Pasi; Hämeri, Kaarle
2009-02-01
The importance of fine particles has become apparent as the knowledge of their effects on health has increased. Fine particle concentrations have been published for outside air, plasma arc cutting, welding, and grinding, but little data exists for the woodworking industry. Sanding was evaluated as the producer of the woodworking industry's finest particles, and was selected as the target study. The number of dust particles in different particle size classes and the mass concentrations were measured in the following environments: workplace air during sanding in plywood production and in the inlet and return air; in the dust emission chamber; and in filter testing. The numbers of fine particles were low, less than 10(4) particles/cm(3) (10(7) particles/L). They were much lower than typical number concentrations near 10(6) particles/cm(3) measured in plasma arc cutting, grinding, and welding. Ultrafine particles in the size class less than 100 nm were found during sanding of MDF (medium density fiberboard) sheets. When the cleaned air is returned to the working areas, the dust content in extraction systems must be monitored continuously. One way to monitor the dust content in the return air is to use an after-filter and measure pressure drop across the filter to indicate leaks in the air-cleaning system. The best after-filtration materials provided a clear increase in pressure drop across the filter in the loading of the filter. The best after-filtration materials proved to be quite effective also for fine particles. The best mass removal efficiencies for fine particles around 0.3 mum were over 80% for some filter materials loaded with sanding wood dust.
Kemperman, F A; Silberbusch, J; Slaats, E H; van Zanten, A P; Weber, J A; Krediet, R T; Arisz, L
1999-05-01
Estimation of glomerular filtration rate (GFR) from plasma creatinine concentration after inhibition of tubular creatinine secretion with cimetidine provides a good assessment in patients with various nephropathies and with non-insulin-dependent diabetes mellitus (NIDDM). The aim of this study was to compare cimetidine-aided GFR estimations using various creatinine assays. In 30 outpatients with NIDDM GFR was measured as the urinary clearance of continuously infused [125I]iothalamate. Plasma creatinine concentration was analysed after oral cimetidine with an alkaline picrate (AP) method, with an enzymatic (PAP) assay and with HPLC. GFR estimations were calculated with the Cockcroft Gault formula (CG). AP creatinine concentrations were significantly higher than PAP or HPLC values. GFR estimations by AP (CG(AP) 66 +/- 19 ml/min/1.73 m2, mean SD) were significantly lower than GFR (89 +/- 30), whereas CG(PAP) (85 +/- 30) and CG(HPLC) (84 +/- 34 ml/min/1.73 m2) were not. Bland and Altman analysis showed a difference between CG(AP) and GFR of -22.4 +/- 17.7 ml/min/1.73 m2; this difference becomes larger when the GFR increases. The difference between CG and GFR was only -3.8 +/- 14.8 ml/min/1.73 m2 for PAP and -4.4 +/- 17.5 ml/min/1.73 m2 for HPLC, without any systematic difference. A good assessment of the GFR from plasma creatinine after cimetidine administration is possible when creatinine is measured with an enzymatic assay or with the less convenient HPLC method. The more widespread and cheaper alkaline picrate assay is not suitable for GFR-estimation.
Novel Particulate Air-Filtration Media: Market Survey
2013-02-01
efficiencies up to 99.999% (0.001% penetration) using two solid-state laser photometers to measure aerosol concentration levels up and downstream of...MN) Tetratex, Ultra-Web, Spider-Web, Dura-Life, Fiber-Web, and Syntek XP DuPont (Wilmington, DE) Spunbond Polypropylene , Nomex KD, and Hybrid...nanofiber technology. The meltblown textiles can be manufactured using polypropylene , polyamides, polylactic acid and biodegradable polymers
A new installation for treatment of road runoff: up-flow filtration by porous polypropylene media.
Lee, B C; Matsui, S; Shimizu, Y; Matsuda, T; Tanaka, Y
2005-01-01
We installed a new device on a paved road to treat runoff from a roadway surface. All the stormwater runoff was transferred into the device and the runoff equivalent to 10 mm/hr or less was treated. The treatment method consists of sedimentation and up-flow filtration with porous polypropylene (PPL) processes. The treated runoff was discharged into the existing storm drainage pipe. The average removal efficiency of the initial runoff at the beginning of rainfall which has high pollution intensity was about 90% for SS, about 70% for COD, about 40% for total phosphorus (T-P), about 80% for Pb and Cd, about 70% for Zn, Cu, Mn and Cr, and about 60% for polycyclic aromatic hydrocarbons (PAHs). The overall removal efficiencies of the experiment that ran for four months remained > 60% of SS, > 40% of COD, > 60% of heavy metals, and > 40% of PAHs. The PPL is excellent for removing smaller size particulates of suspended solids, which originate basically from diesel exhaust, as well as larger size particulates from automobile tires, asphalt roads, and other accumulated source(s) of clay and sand, etc.
Hajji-Hedfi, Lobna; Regaieg, Hajer; Larayedh, Asma; Chihani, Noura; Horrigue-Raouani, Najet
2017-09-23
The efficacy of Verticillium leptobactrum isolate (HR1) was evaluated in the control of root-knot nematode and Fusarium wilt fungus under laboratory and greenhouse conditions. Five concentrations of V. leptobactrum (HR1) isolate were tested for their nematicidal and fungicidal activities against Meloidogyne javanica and Fusarium oxysporum f.sp. lycopersici in vitro. Laboratory trials showed that mycelium growth inhibition of Fusarium wilt fungus was correlated to the increase of the concentration of culture filtrate. All dilutions showed efficiency in reducing the growth of Fusarium oxysporum f.sp. lycopersici. The greatest nematicidal activity was observed at 50, 75, and 100% filtrate dilutions. The egg hatching percentage reached 42%, and the juvenile's corrected mortality registered 90% for the above treatments. In greenhouse experiment, the biocontrol agent fungus enhanced significantly tomato growth components (height and weight of plant and root). The multiplication rate of root-knot nematode and the Fusarium wilt disease incidence declined significantly with soil application of V. leptobactrum as with chemical treatments. The isolate HR1 was efficient to control wilt disease complex caused by M. javanica and Fusarium oxysporum f.sp. lycopersici.
Chang, Fangfang; Qu, Jiuhui; Liu, Ruiping; Zhao, Xu; Lei, Pengju
2010-01-01
A treatment unit packed by granular adsorbent of Fe-Mn binary oxide incorporated into diatomite (FMBO(1:1)-diatomite) was studied to remove arsenic from anaerobic groundwater without any pre-treatment or post-treatment. The raw anaerobic groundwater containing 35-45 microg/L of arsenic was collected from suburb of Beijing. Arsenic (III) constituted roughly 60%-80% of the total arsenic content. Approximately 7,000 bed volumes (ratio of effluent volume to adsorbent volume) treated water with arsenic concentration below 10 microg/L were produced in the operation period of four months. The regeneration of FMBO (1:1)-diatomite had been operated for 15 times. In the first stage, the regeneration process significantly improved the adsorption capacity of FMBO (1:1)-diatomite. With increased loading amount of Fe-Mn binary oxide, the adsorption capacity for arsenic decreased 20%-40%. Iron and manganese in anaerobic groundwater were oxidized and adsorptive filtrated by FMBO (1:1)-diatomite efficiently. The final concentrations of iron and manganese in effluents were nearly zero. The continued safe performance of the treatment units proved that adsorbent FMBO (1:1)-diatomite had high oxidation ability and exhibited strong adsorptive filtration.
Catalytic polymer-clay composite for enhanced removal and degradation of diazinon.
Shabtai, Itamar A; Mishael, Yael G
2017-08-05
It is well established that organophosphate pesticides, such as diazinon, pose environmental and health risks. Diazinon is prone to rapid acidic hydrolysis, forming the less toxic compound 2-isopropyl-6-methyl-4-pyrimidinol (IMP). In this study, diazinon surface catalyzed hydrolysis was achieved by its adsorption to a composite, based on protonated poly (4-vinyl-pyridine-co-styrene) (HPVPcoS) and montmorillonite (MMT) clay. The adsorption affinity and kinetics of diazinon to HPVPcoS-MMT were significantly higher than those obtained to the deprotonated PVPcoS-MMT, emphasizing the importance of hydrogen bonding. Correspondingly, diazinon filtration by HPVPcoS-MMT columns was highly efficient (100% for 100 pore volumes), while filtration by columns of PVPcoS-MMT or granular activated carbon (GAC) reached only 55% and 85%, respectively. Regeneration of HPVPcoS-MMT by pH increase was demonstrated and sorbent reuse was successful, whereas regeneration and reuse of GAC and PVPcoS-MMT were inefficient. Proton transfer from HPVPcos-MMT to diazinon, investigated by FTIR analysis, supports the suggested mechanism of surface catalyzed hydrolysis. These findings demonstrate the applicability of such bi-functional sorbents, to adsorb and degrade pollutants, for efficient water treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
Fish Gill Inspired Crossflow for Efficient and Continuous Collection of Spilled Oil.
Dou, Yuhai; Tian, Dongliang; Sun, Ziqi; Liu, Qiannan; Zhang, Na; Kim, Jung Ho; Jiang, Lei; Dou, Shi Xue
2017-03-28
Developing an effective system to clean up large-scale oil spills is of great significance due to their contribution to severe environmental pollution and destruction. Superwetting membranes have been widely studied for oil/water separation. The separation, however, adopts a gravity-driven approach that is inefficient and discontinuous due to quick fouling of the membrane by oil. Herein, inspired by the crossflow filtration behavior in fish gills, we propose a crossflow approach via a hydrophilic, tilted gradient membrane for spilled oil collection. In crossflow collection, as the oil/water flows parallel to the hydrophilic membrane surface, water is gradually filtered through the pores, while oil is repelled, transported, and finally collected for storage. Owing to the selective gating behavior of the water-sealed gradient membrane, the large pores at the bottom with high water flux favor fast water filtration, while the small pores at the top with strong oil repellency allow easy oil transportation. In addition, the gradient membrane exhibits excellent antifouling properties due to the protection of the water layer. Therefore, this bioinspired crossflow approach enables highly efficient and continuous spilled oil collection, which is very promising for the cleanup of large-scale oil spills.
Boscan, Pedro; Pypendop, Bruno H; Siao, Kristine T; Francey, Thierry; Dowers, Kristy; Cowgill, Larry; Ilkiw, Jan E
2010-05-01
To determine fluid retention, glomerular filtration rate, and urine output in dogs anesthetized for a surgical orthopedic procedure. 23 dogs treated with a tibial plateau leveling osteotomy. 12 dogs were used as a control group. Cardiac output was measured in 5 dogs, and 6 dogs received carprofen for at least 14 days. Dogs received oxymorphone, atropine, propofol, and isoflurane for anesthesia (duration, 4 hours). Urine and blood samples were obtained for analysis every 30 minutes. Lactated Ringer's solution was administered at 10 mL/kg/h. Urine output was measured and glomerular filtration rate was estimated. Fluid retention was measured by use of body weight, fluid balance, and bioimpedance spectroscopy. No difference was found among control, cardiac output, or carprofen groups, so data were combined. Median urine output and glomerular filtration rate were 0.46 mL/kg/h and 1.84 mL/kg/min. Dogs retained a large amount of fluids during anesthesia, as indicated by increased body weight, positive fluid balance, increased total body water volume, and increased extracellular fluid volume. The PCV, total protein concentration, and esophageal temperature decreased in a linear manner. Dogs anesthetized for a tibial plateau leveling osteotomy retained a large amount of fluids, had low urinary output, and had decreased PCV, total protein concentration, and esophageal temperature. Evaluation of urine output alone in anesthetized dogs may not be an adequate indicator of fluid balance.
NASA Astrophysics Data System (ADS)
Sabino, Luis G.; Guimarães, Wellinson Gadelha; Costa, Pedro Mikael; Carepo, Marta S. P.; Gondim, Ana C. S.; Lopes, Luiz G. F.; Sousa, Eduardo H. S.
2016-03-01
The aim of this study is to investigate the structural organization and oligomerization properties of the sensory kinase protein DevS using low-angle light scattering (LALS) and gel filtration chromatography (HPLC). In addition, the structural characteristics of FixL and BSA were investigated and compared with DevS to better elucidate LALS technique. DevS is a direct and specific O2 sensing protein in Mycobacterium tuberculosis and acts as an activator of the transcription factor protein DevR. This latter triggers the latency state of tuberculosis under hypoxic conditions. DevS has been briefly evaluated under different conditions of concentration, ionic strength and temperature. LALS and gel filtration (HPLC) analysis were performed right after DevS purification process. The results of LALS for BSA proved to be highly reliable with a Rh value of c.a. 3.7 nm. Considering BSA a globular protein, the molecular weight estimative, using LALS was near 67 KDa, which is reasonably within the value reported in the literature. Preliminary LALS results showed a hydrodynamic radius (Rh) varying from 4.2-15.0 nm for DevS protein, and an average of 6.7 nm. These data supported, along with gel filtration, a dimer (~130 KDa) and tetramer (255 KDa) as the main DevS species. Additionally, it was found higher oligomeric species by gel filtration suggesting either an equilibrium of oligomers or an aggregation process that deserves further studies.
Drawbacks of Dialysis Procedures for Removal of EDTA
Mónico, Andreia; Martínez-Senra, Eva; Cañada, F. Javier; Zorrilla, Silvia
2017-01-01
Ethylenediaminetetraacetic acid (EDTA) is a chelating agent commonly used in protein purification, both to eliminate contaminating divalent cations and to inhibit protease activity. For a number of subsequent applications EDTA needs to be exhaustively removed. Most purification methods rely in extensive dialysis and/or gel filtration in order to exchange or remove protein buffer components, including metal chelators. We report here that dialysis protocols, even as extensive as those typically employed for protein refolding, may not effectively remove EDTA, which is reduced only by approximately two-fold and it also persists after spin-column gel filtration, as determined by NMR and by colorimetric methods. Remarkably, the most efficient removal was achieved by ultrafiltration, after which EDTA became virtually undetectable. These results highlight a potentially widespread source of experimental variability affecting free divalent cation concentrations in protein applications. PMID:28099451
Mayhead, Elyssia; Llewellyn, Carole A.; Fuentes-Grünewald, Claudio
2018-01-01
The nutrient removal efficiency of Chlorella vulgaris cultivated in domestic wastewater was investigated, along with the potential to use membrane filtration as a pre-treatment tool during the wastewater treatment process. Chlorella vulgaris was batch cultivated for 12 days in a bubble column system with two different wastewater treatments. Maximum uptake of 94.18% ammonium (NH4-N) and 97.69% ortho-phosphate (PO4-P) occurred in 0.2 μm membrane filtered primary wastewater. Membrane filtration enhanced the nutrient uptake performance of C. vulgaris by removing bacteria, protozoa, colloidal particles and suspended solids, thereby improving light availability for photosynthesis. The results of this study suggest that growing C. vulgaris in nutrient rich membrane filtered wastewater provides an option for domestic wastewater treatment to improve the quality of the final effluent. PMID:29351200
Yamada, Hiroya; Takano, Toru; Kihara, Minoru; Hirokawa, Mitsuyoshi; Yoshida, Hiroshi; Watanabe, Mikio; Iwatani, Yoshinori; Hidaka, Yoh; Miyauchi, Akira
2012-01-01
Measurement of gene expression levels in thyroid tumor cells in aspirates was difficult because it is interfered with peripheral blood cells or infiltrating lymphocytes. In this study, we established a novel method to separate thyroid tumor cells from blood cells efficiently with mesh filtration. The expression level of trefoil factor 3 (TFF3) mRNA was estimated using LGALS3 mRNA as an internal control (T/G ratio) in 148 preoperative thyroid aspirates. Intra-assay coefficients of variation (CV) of T/G ratio for high, moderate, and low samples were 6.5%, 2.5%, and 9.7%, respectively, and inter-assay CV for high, moderate, and low samples were 27.7%, 21.9%, and 38.2%, respectively. Nondiagnostic samples in terms of T/G ratio and cytology were 12.2% and 16.9%, respectively. We observed no interference with the data by contaminating blood cells. Among these patients, 12 patients received more than two repeated aspirations. We did not observe a marked day-to-day variation except in two cases. All 13 preoperative aspirates diagnosed as malignant by cytology showed an extremely low T/G ratio, whereas 93 aspirates diagnosed as benign by cytology showed extremely varied T/G ratios and 21.5% of them showed a T/G ratio below the cut-off value. Eleven cases underwent surgery. All nodules showing a low T/G ratio were diagnosed as papillary carcinoma by pathological diagnosis. However, one nodule diagnosed as follicular adenoma after surgery showed a high T/G ratio. Our present method may be a promising preoperative test for measuring mRNAs in thyroid aspirates.