Sample records for estimating human body

  1. Position Estimation Method of Medical Implanted Devices Using Estimation of Propagation Velocity inside Human Body

    NASA Astrophysics Data System (ADS)

    Kawasaki, Makoto; Kohno, Ryuji

    Wireless communication devices in the field of medical implant, such as cardiac pacemakers and capsule endoscopes, have been studied and developed to improve healthcare systems. Especially it is very important to know the range and position of each device because it will contribute to an optimization of the transmission power. We adopt the time-based approach of position estimation using ultra wideband signals. However, the propagation velocity inside the human body differs in each tissue and each frequency. Furthermore, the human body is formed of various tissues with complex structures. For this reason, propagation velocity is different at a different point inside human body and the received signal so distorted through the channel inside human body. In this paper, we apply an adaptive template synthesis method in multipath channel for calculate the propagation time accurately based on the output of the correlator between the transmitter and the receiver. Furthermore, we propose a position estimation method using an estimation of the propagation velocity inside the human body. In addition, we show by computer simulation that the proposal method can perform accurate positioning with a size of medical implanted devices such as a medicine capsule.

  2. Effect of body composition methodology on heritability estimation of body fatness

    USDA-ARS?s Scientific Manuscript database

    Heritability estimates of human body fatness vary widely and the contribution of body composition methodology to this variability is unknown. The effect of body composition methodology on estimations of genetic and environmental contributions to body fatness variation was examined in 78 adult male ...

  3. Body size, body proportions, and encephalization in a Middle Pleistocene archaic human from northern China.

    PubMed

    Rosenberg, Karen R; Zuné, Lü; Ruff, Christopher B

    2006-03-07

    The unusual discovery of associated cranial and postcranial elements from a single Middle Pleistocene fossil human allows us to calculate body proportions and relative cranial capacity (encephalization quotient) for that individual rather than rely on estimates based on sample means from unassociated specimens. The individual analyzed here (Jinniushan) from northeastern China at 260,000 years ago is the largest female specimen yet known in the human fossil record and has body proportions (body height relative to body breadth and relative limb length) typical of cold-adapted populations elsewhere in the world. Her encephalization quotient of 4.15 is similar to estimates for late Middle Pleistocene humans that are based on mean body size and mean brain size from unassociated specimens.

  4. Body mass estimates of hominin fossils and the evolution of human body size.

    PubMed

    Grabowski, Mark; Hatala, Kevin G; Jungers, William L; Richmond, Brian G

    2015-08-01

    Body size directly influences an animal's place in the natural world, including its energy requirements, home range size, relative brain size, locomotion, diet, life history, and behavior. Thus, an understanding of the biology of extinct organisms, including species in our own lineage, requires accurate estimates of body size. Since the last major review of hominin body size based on postcranial morphology over 20 years ago, new fossils have been discovered, species attributions have been clarified, and methods improved. Here, we present the most comprehensive and thoroughly vetted set of individual fossil hominin body mass predictions to date, and estimation equations based on a large (n = 220) sample of modern humans of known body masses. We also present species averages based exclusively on fossils with reliable taxonomic attributions, estimates of species averages by sex, and a metric for levels of sexual dimorphism. Finally, we identify individual traits that appear to be the most reliable for mass estimation for each fossil species, for use when only one measurement is available for a fossil. Our results show that many early hominins were generally smaller-bodied than previously thought, an outcome likely due to larger estimates in previous studies resulting from the use of large-bodied modern human reference samples. Current evidence indicates that modern human-like large size first appeared by at least 3-3.5 Ma in some Australopithecus afarensis individuals. Our results challenge an evolutionary model arguing that body size increased from Australopithecus to early Homo. Instead, we show that there is no reliable evidence that the body size of non-erectus early Homo differed from that of australopiths, and confirm that Homo erectus evolved larger average body size than earlier hominins. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Revised Estimates for the Number of Human and Bacteria Cells in the Body.

    PubMed

    Sender, Ron; Fuchs, Shai; Milo, Ron

    2016-08-01

    Reported values in the literature on the number of cells in the body differ by orders of magnitude and are very seldom supported by any measurements or calculations. Here, we integrate the most up-to-date information on the number of human and bacterial cells in the body. We estimate the total number of bacteria in the 70 kg "reference man" to be 3.8·1013. For human cells, we identify the dominant role of the hematopoietic lineage to the total count (≈90%) and revise past estimates to 3.0·1013 human cells. Our analysis also updates the widely-cited 10:1 ratio, showing that the number of bacteria in the body is actually of the same order as the number of human cells, and their total mass is about 0.2 kg.

  6. Revised Estimates for the Number of Human and Bacteria Cells in the Body

    PubMed Central

    Milo, Ron

    2016-01-01

    Reported values in the literature on the number of cells in the body differ by orders of magnitude and are very seldom supported by any measurements or calculations. Here, we integrate the most up-to-date information on the number of human and bacterial cells in the body. We estimate the total number of bacteria in the 70 kg "reference man" to be 3.8·1013. For human cells, we identify the dominant role of the hematopoietic lineage to the total count (≈90%) and revise past estimates to 3.0·1013 human cells. Our analysis also updates the widely-cited 10:1 ratio, showing that the number of bacteria in the body is actually of the same order as the number of human cells, and their total mass is about 0.2 kg. PMID:27541692

  7. Human blood metabolite timetable indicates internal body time

    PubMed Central

    Kasukawa, Takeya; Sugimoto, Masahiro; Hida, Akiko; Minami, Yoichi; Mori, Masayo; Honma, Sato; Honma, Ken-ichi; Mishima, Kazuo; Soga, Tomoyoshi; Ueda, Hiroki R.

    2012-01-01

    A convenient way to estimate internal body time (BT) is essential for chronotherapy and time-restricted feeding, both of which use body-time information to maximize potency and minimize toxicity during drug administration and feeding, respectively. Previously, we proposed a molecular timetable based on circadian-oscillating substances in multiple mouse organs or blood to estimate internal body time from samples taken at only a few time points. Here we applied this molecular-timetable concept to estimate and evaluate internal body time in humans. We constructed a 1.5-d reference timetable of oscillating metabolites in human blood samples with 2-h sampling frequency while simultaneously controlling for the confounding effects of activity level, light, temperature, sleep, and food intake. By using this metabolite timetable as a reference, we accurately determined internal body time within 3 h from just two anti-phase blood samples. Our minimally invasive, molecular-timetable method with human blood enables highly optimized and personalized medicine. PMID:22927403

  8. Estimation of the whole-body averaged SAR of grounded human models for plane wave exposure at respective resonance frequencies.

    PubMed

    Hirata, Akimasa; Yanase, Kazuya; Laakso, Ilkka; Chan, Kwok Hung; Fujiwara, Osamu; Nagaoka, Tomoaki; Watanabe, Soichi; Conil, Emmanuelle; Wiart, Joe

    2012-12-21

    According to the international guidelines, the whole-body averaged specific absorption rate (WBA-SAR) is used as a metric of basic restriction for radio-frequency whole-body exposure. It is well known that the WBA-SAR largely depends on the frequency of the incident wave for a given incident power density. The frequency at which the WBA-SAR becomes maximal is called the 'resonance frequency'. Our previous study proposed a scheme for estimating the WBA-SAR at this resonance frequency based on an analogy between the power absorption characteristic of human models in free space and that of a dipole antenna. However, a scheme for estimating the WBA-SAR in a grounded human has not been discussed sufficiently, even though the WBA-SAR in a grounded human is larger than that in an ungrounded human. In this study, with the use of the finite-difference time-domain method, the grounded condition is confirmed to be the worst-case exposure for human body models in a standing posture. Then, WBA-SARs in grounded human models are calculated at their respective resonant frequencies. A formula for estimating the WBA-SAR of a human standing on the ground is proposed based on an analogy with a quarter-wavelength monopole antenna. First, homogenized human body models are shown to provide the conservative WBA-SAR as compared with anatomically based models. Based on the formula proposed here, the WBA-SARs in grounded human models are approximately 10% larger than those in free space. The variability of the WBA-SAR was shown to be ±30% even for humans of the same age, which is caused by the body shape.

  9. A Bayesian Framework for Human Body Pose Tracking from Depth Image Sequences

    PubMed Central

    Zhu, Youding; Fujimura, Kikuo

    2010-01-01

    This paper addresses the problem of accurate and robust tracking of 3D human body pose from depth image sequences. Recovering the large number of degrees of freedom in human body movements from a depth image sequence is challenging due to the need to resolve the depth ambiguity caused by self-occlusions and the difficulty to recover from tracking failure. Human body poses could be estimated through model fitting using dense correspondences between depth data and an articulated human model (local optimization method). Although it usually achieves a high accuracy due to dense correspondences, it may fail to recover from tracking failure. Alternately, human pose may be reconstructed by detecting and tracking human body anatomical landmarks (key-points) based on low-level depth image analysis. While this method (key-point based method) is robust and recovers from tracking failure, its pose estimation accuracy depends solely on image-based localization accuracy of key-points. To address these limitations, we present a flexible Bayesian framework for integrating pose estimation results obtained by methods based on key-points and local optimization. Experimental results are shown and performance comparison is presented to demonstrate the effectiveness of the proposed approach. PMID:22399933

  10. Hierarchical human action recognition around sleeping using obscured posture information

    NASA Astrophysics Data System (ADS)

    Kudo, Yuta; Sashida, Takehiko; Aoki, Yoshimitsu

    2015-04-01

    This paper presents a new approach for human action recognition around sleeping with the human body parts locations and the positional relationship between human and sleeping environment. Body parts are estimated from the depth image obtained by a time-of-flight (TOF) sensor using oriented 3D normal vector. Issues in action recognition of sleeping situation are the demand of availability in darkness, and hiding of the human body by duvets. Therefore, the extraction of image features is difficult since color and edge features are obscured by covers. Thus, first in our method, positions of four parts of the body (head, torso, thigh, and lower leg) are estimated by using the shape model of bodily surface constructed by oriented 3D normal vector. This shape model can represent the surface shape of rough body, and is effective in robust posture estimation of the body hidden with duvets. Then, action descriptor is extracted from the position of each body part. The descriptor includes temporal variation of each part of the body and spatial vector of position of the parts and the bed. Furthermore, this paper proposes hierarchical action classes and classifiers to improve the indistinct action classification. Classifiers are composed of two layers, and recognize human action by using the action descriptor. First layer focuses on spatial descriptor and classifies action roughly. Second layer focuses on temporal descriptor and classifies action finely. This approach achieves a robust recognition of obscured human by using the posture information and the hierarchical action recognition.

  11. Estimation of skeletal movement of human locomotion from body surface shapes using dynamic spatial video camera (DSVC) and 4D human model.

    PubMed

    Saito, Toshikuni; Suzuki, Naoki; Hattori, Asaki; Suzuki, Shigeyuki; Hayashibe, Mitsuhiro; Otake, Yoshito

    2006-01-01

    We have been developing a DSVC (Dynamic Spatial Video Camera) system to measure and observe human locomotion quantitatively and freely. A 4D (four-dimensional) human model with detailed skeletal structure, joint, muscle, and motor functionality has been built. The purpose of our research was to estimate skeletal movements from body surface shapes using DSVC and the 4D human model. For this purpose, we constructed a body surface model of a subject and resized the standard 4D human model to match with geometrical features of the subject's body surface model. Software that integrates the DSVC system and the 4D human model, and allows dynamic skeletal state analysis from body surface movement data was also developed. We practically applied the developed system in dynamic skeletal state analysis of a lower limb in motion and were able to visualize the motion using geometrically resized standard 4D human model.

  12. Novel joint TOA/RSSI-based WCE location tracking method without prior knowledge of biological human body tissues.

    PubMed

    Ito, Takahiro; Anzai, Daisuke; Jianqing Wang

    2014-01-01

    This paper proposes a novel joint time of arrival (TOA)/received signal strength indicator (RSSI)-based wireless capsule endoscope (WCE) location tracking method without prior knowledge of biological human tissues. Generally, TOA-based localization can achieve much higher localization accuracy than other radio frequency-based localization techniques, whereas wireless signals transmitted from a WCE pass through various kinds of human body tissues, as a result, the propagation velocity inside a human body should be different from one in free space. Because the variation of propagation velocity is mainly affected by the relative permittivity of human body tissues, instead of pre-measurement for the relative permittivity in advance, we simultaneously estimate not only the WCE location but also the relative permittivity information. For this purpose, this paper first derives the relative permittivity estimation model with measured RSSI information. Then, we pay attention to a particle filter algorithm with the TOA-based localization and the RSSI-based relative permittivity estimation. Our computer simulation results demonstrates that the proposed tracking methods with the particle filter can accomplish an excellent localization accuracy of around 2 mm without prior information of the relative permittivity of the human body tissues.

  13. New model for estimating the relationship between surface area and volume in the human body using skeletal remains.

    PubMed

    Kasabova, Boryana E; Holliday, Trenton W

    2015-04-01

    A new model for estimating human body surface area and body volume/mass from standard skeletal metrics is presented. This model is then tested against both 1) "independently estimated" body surface areas and "independently estimated" body volume/mass (both derived from anthropometric data) and 2) the cylindrical model of Ruff. The model is found to be more accurate in estimating both body surface area and body volume/mass than the cylindrical model, but it is more accurate in estimating body surface area than it is for estimating body volume/mass (as reflected by the standard error of the estimate when "independently estimated" surface area or volume/mass is regressed on estimates derived from the present model). Two practical applications of the model are tested. In the first test, the relative contribution of the limbs versus the trunk to the body's volume and surface area is compared between "heat-adapted" and "cold-adapted" populations. As expected, the "cold-adapted" group has significantly more of its body surface area and volume in its trunk than does the "heat-adapted" group. In the second test, we evaluate the effect of variation in bi-iliac breadth, elongated or foreshortened limbs, and differences in crural index on the body's surface area to volume ratio (SA:V). Results indicate that the effects of bi-iliac breadth on SA:V are substantial, while those of limb lengths and (especially) the crural index are minor, which suggests that factors other than surface area relative to volume are driving morphological variation and ecogeographical patterning in limb prorportions. © 2014 Wiley Periodicals, Inc.

  14. Dynamic Human Body Modeling Using a Single RGB Camera.

    PubMed

    Zhu, Haiyu; Yu, Yao; Zhou, Yu; Du, Sidan

    2016-03-18

    In this paper, we present a novel automatic pipeline to build personalized parametric models of dynamic people using a single RGB camera. Compared to previous approaches that use monocular RGB images, our system can model a 3D human body automatically and incrementally, taking advantage of human motion. Based on coarse 2D and 3D poses estimated from image sequences, we first perform a kinematic classification of human body parts to refine the poses and obtain reconstructed body parts. Next, a personalized parametric human model is generated by driving a general template to fit the body parts and calculating the non-rigid deformation. Experimental results show that our shape estimation method achieves comparable accuracy with reconstructed models using depth cameras, yet requires neither user interaction nor any dedicated devices, leading to the feasibility of using this method on widely available smart phones.

  15. Dynamic Human Body Modeling Using a Single RGB Camera

    PubMed Central

    Zhu, Haiyu; Yu, Yao; Zhou, Yu; Du, Sidan

    2016-01-01

    In this paper, we present a novel automatic pipeline to build personalized parametric models of dynamic people using a single RGB camera. Compared to previous approaches that use monocular RGB images, our system can model a 3D human body automatically and incrementally, taking advantage of human motion. Based on coarse 2D and 3D poses estimated from image sequences, we first perform a kinematic classification of human body parts to refine the poses and obtain reconstructed body parts. Next, a personalized parametric human model is generated by driving a general template to fit the body parts and calculating the non-rigid deformation. Experimental results show that our shape estimation method achieves comparable accuracy with reconstructed models using depth cameras, yet requires neither user interaction nor any dedicated devices, leading to the feasibility of using this method on widely available smart phones. PMID:26999159

  16. Accurate estimation of human body orientation from RGB-D sensors.

    PubMed

    Liu, Wu; Zhang, Yongdong; Tang, Sheng; Tang, Jinhui; Hong, Richang; Li, Jintao

    2013-10-01

    Accurate estimation of human body orientation can significantly enhance the analysis of human behavior, which is a fundamental task in the field of computer vision. However, existing orientation estimation methods cannot handle the various body poses and appearances. In this paper, we propose an innovative RGB-D-based orientation estimation method to address these challenges. By utilizing the RGB-D information, which can be real time acquired by RGB-D sensors, our method is robust to cluttered environment, illumination change and partial occlusions. Specifically, efficient static and motion cue extraction methods are proposed based on the RGB-D superpixels to reduce the noise of depth data. Since it is hard to discriminate all the 360 (°) orientation using static cues or motion cues independently, we propose to utilize a dynamic Bayesian network system (DBNS) to effectively employ the complementary nature of both static and motion cues. In order to verify our proposed method, we build a RGB-D-based human body orientation dataset that covers a wide diversity of poses and appearances. Our intensive experimental evaluations on this dataset demonstrate the effectiveness and efficiency of the proposed method.

  17. Sensing power transfer between the human body and the environment.

    PubMed

    Veltink, Peter H; Kortier, Henk; Schepers, H Martin

    2009-06-01

    The power transferred between the human body and the environment at any time and the work performed are important quantities to be estimated when evaluating and optimizing the physical interaction between the human body and the environment in sports, physical labor, and rehabilitation. It is the objective of the current paper to present a concept for estimating power transfer between the human body and the environment during free motions and using sensors at the interface, not requiring measurement systems in the environment, and to experimentally demonstrate this principle. Mass and spring loads were moved by hand over a fixed height difference via varying free movement trajectories. Kinematic and kinetic quantities were measured in the handle between the hand and the load. 3-D force and moments were measured using a 6 DOF force/moment sensor module, 3-D movement was measured using 3-D accelerometers and angular velocity sensors. The orientation was estimated from the angular velocity, using the initial orientation as a begin condition. The accelerometer signals were expressed in global coordinates using this orientation information. Velocity was estimated by integrating acceleration in global coordinates, obtained by adding gravitational acceleration to the accelerometer signals. Zero start and end velocities were used as begin and end conditions. Power was calculated as the sum of the inner products of velocity and force and of angular velocity and moment, and work was estimated by integrating power over time. The estimated performed work was compared to the potential energy difference corresponding to the change in height of the loads and appeared to be accurate within 4% for varying movements with net displacements and varying loads (mass and spring). The principle of estimating power transfer demonstrated in this paper can be used in future interfaces between the human body and the environment instrumented with body-mounted miniature 3-D force and acceleration sensors.

  18. Human Body 3D Posture Estimation Using Significant Points and Two Cameras

    PubMed Central

    Juang, Chia-Feng; Chen, Teng-Chang; Du, Wei-Chin

    2014-01-01

    This paper proposes a three-dimensional (3D) human posture estimation system that locates 3D significant body points based on 2D body contours extracted from two cameras without using any depth sensors. The 3D significant body points that are located by this system include the head, the center of the body, the tips of the feet, the tips of the hands, the elbows, and the knees. First, a linear support vector machine- (SVM-) based segmentation method is proposed to distinguish the human body from the background in red, green, and blue (RGB) color space. The SVM-based segmentation method uses not only normalized color differences but also included angle between pixels in the current frame and the background in order to reduce shadow influence. After segmentation, 2D significant points in each of the two extracted images are located. A significant point volume matching (SPVM) method is then proposed to reconstruct the 3D significant body point locations by using 2D posture estimation results. Experimental results show that the proposed SVM-based segmentation method shows better performance than other gray level- and RGB-based segmentation approaches. This paper also shows the effectiveness of the 3D posture estimation results in different postures. PMID:24883422

  19. Non-invasive body temperature measurement of wild chimpanzees using fecal temperature decline.

    PubMed

    Jensen, Siv Aina; Mundry, Roger; Nunn, Charles L; Boesch, Christophe; Leendertz, Fabian H

    2009-04-01

    New methods are required to increase our understanding of pathologic processes in wild mammals. We developed a noninvasive field method to estimate the body temperature of wild living chimpanzees habituated to humans, based on statistically fitting temperature decline of feces after defecation. The method was established with the use of control measures of human rectal temperature and subsequent changes in fecal temperature over time. The method was then applied to temperature data collected from wild chimpanzee feces. In humans, we found good correspondence between the temperature estimated by the method and the actual rectal temperature that was measured (maximum deviation 0.22 C). The method was successfully applied and the average estimated temperature of the chimpanzees was 37.2 C. This simple-to-use field method reliably estimates the body temperature of wild chimpanzees and probably also other large mammals.

  20. A cascaded two-step Kalman filter for estimation of human body segment orientation using MEMS-IMU.

    PubMed

    Zihajehzadeh, S; Loh, D; Lee, M; Hoskinson, R; Park, E J

    2014-01-01

    Orientation of human body segments is an important quantity in many biomechanical analyses. To get robust and drift-free 3-D orientation, raw data from miniature body worn MEMS-based inertial measurement units (IMU) should be blended in a Kalman filter. Aiming at less computational cost, this work presents a novel cascaded two-step Kalman filter orientation estimation algorithm. Tilt angles are estimated in the first step of the proposed cascaded Kalman filter. The estimated tilt angles are passed to the second step of the filter for yaw angle calculation. The orientation results are benchmarked against the ones from a highly accurate tactical grade IMU. Experimental results reveal that the proposed algorithm provides robust orientation estimation in both kinematically and magnetically disturbed conditions.

  1. Robust automatic measurement of 3D scanned models for the human body fat estimation.

    PubMed

    Giachetti, Andrea; Lovato, Christian; Piscitelli, Francesco; Milanese, Chiara; Zancanaro, Carlo

    2015-03-01

    In this paper, we present an automatic tool for estimating geometrical parameters from 3-D human scans independent on pose and robustly against the topological noise. It is based on an automatic segmentation of body parts exploiting curve skeleton processing and ad hoc heuristics able to remove problems due to different acquisition poses and body types. The software is able to locate body trunk and limbs, detect their directions, and compute parameters like volumes, areas, girths, and lengths. Experimental results demonstrate that measurements provided by our system on 3-D body scans of normal and overweight subjects acquired in different poses are highly correlated with the body fat estimates obtained on the same subjects with dual-energy X-rays absorptiometry (DXA) scanning. In particular, maximal lengths and girths, not requiring precise localization of anatomical landmarks, demonstrate a good correlation (up to 96%) with the body fat and trunk fat. Regression models based on our automatic measurements can be used to predict body fat values reasonably well.

  2. Experimental Quasi-Microwave Whole-Body Averaged SAR Estimation Method Using Cylindrical-External Field Scanning

    NASA Astrophysics Data System (ADS)

    Kawamura, Yoshifumi; Hikage, Takashi; Nojima, Toshio

    The aim of this study is to develop a new whole-body averaged specific absorption rate (SAR) estimation method based on the external-cylindrical field scanning technique. This technique is adopted with the goal of simplifying the dosimetry estimation of human phantoms that have different postures or sizes. An experimental scaled model system is constructed. In order to examine the validity of the proposed method for realistic human models, we discuss the pros and cons of measurements and numerical analyses based on the finite-difference time-domain (FDTD) method. We consider the anatomical European human phantoms and plane-wave in the 2GHz mobile phone frequency band. The measured whole-body averaged SAR results obtained by the proposed method are compared with the results of the FDTD analyses.

  3. Human location estimation using thermopile array sensor

    NASA Astrophysics Data System (ADS)

    Parnin, S.; Rahman, M. M.

    2017-11-01

    Utilization of Thermopile sensor at an early stage of human detection is challenging as there are many things that produce thermal heat other than human such as electrical appliances and animals. Therefrom, an algorithm for early presence detection has been developed through the study of human body temperature behaviour with respect to the room temperature. The change in non-contact detected temperature of human varied according to body parts. In an indoor room, upper parts of human body change up to 3°C whereas lower part ranging from 0.58°C to 1.71°C. The average changes in temperature of human is used as a conditional set-point value in the program algorithm to detect human presence. The current position of human and its respective angle is gained when human is presence at certain pixels of Thermopile’s sensor array. Human position is estimated successfully as the developed sensory system is tested to the actuator of a stand fan.

  4. Human body mass estimation: a comparison of "morphometric" and "mechanical" methods.

    PubMed

    Auerbach, Benjamin M; Ruff, Christopher B

    2004-12-01

    In the past, body mass was reconstructed from hominin skeletal remains using both "mechanical" methods which rely on the support of body mass by weight-bearing skeletal elements, and "morphometric" methods which reconstruct body mass through direct assessment of body size and shape. A previous comparison of two such techniques, using femoral head breadth (mechanical) and stature and bi-iliac breadth (morphometric), indicated a good general correspondence between them (Ruff et al. [1997] Nature 387:173-176). However, the two techniques were never systematically compared across a large group of modern humans of diverse body form. This study incorporates skeletal measures taken from 1,173 Holocene adult individuals, representing diverse geographic origins, body sizes, and body shapes. Femoral head breadth, bi-iliac breadth (after pelvic rearticulation), and long bone lengths were measured on each individual. Statures were estimated from long bone lengths using appropriate reference samples. Body masses were calculated using three available femoral head breadth (FH) formulae and the stature/bi-iliac breadth (STBIB) formula, and compared. All methods yielded similar results. Correlations between FH estimates and STBIB estimates are 0.74-0.81. Slight differences in results between the three FH estimates can be attributed to sampling differences in the original reference samples, and in particular, the body-size ranges included in those samples. There is no evidence for systematic differences in results due to differences in body proportions. Since the STBIB method was validated on other samples, and the FH methods produced similar estimates, this argues that either may be applied to skeletal remains with some confidence. 2004 Wiley-Liss, Inc.

  5. Moving human full body and body parts detection, tracking, and applications on human activity estimation, walking pattern and face recognition

    NASA Astrophysics Data System (ADS)

    Chen, Hai-Wen; McGurr, Mike

    2016-05-01

    We have developed a new way for detection and tracking of human full-body and body-parts with color (intensity) patch morphological segmentation and adaptive thresholding for security surveillance cameras. An adaptive threshold scheme has been developed for dealing with body size changes, illumination condition changes, and cross camera parameter changes. Tests with the PETS 2009 and 2014 datasets show that we can obtain high probability of detection and low probability of false alarm for full-body. Test results indicate that our human full-body detection method can considerably outperform the current state-of-the-art methods in both detection performance and computational complexity. Furthermore, in this paper, we have developed several methods using color features for detection and tracking of human body-parts (arms, legs, torso, and head, etc.). For example, we have developed a human skin color sub-patch segmentation algorithm by first conducting a RGB to YIQ transformation and then applying a Subtractive I/Q image Fusion with morphological operations. With this method, we can reliably detect and track human skin color related body-parts such as face, neck, arms, and legs. Reliable body-parts (e.g. head) detection allows us to continuously track the individual person even in the case that multiple closely spaced persons are merged. Accordingly, we have developed a new algorithm to split a merged detection blob back to individual detections based on the detected head positions. Detected body-parts also allow us to extract important local constellation features of the body-parts positions and angles related to the full-body. These features are useful for human walking gait pattern recognition and human pose (e.g. standing or falling down) estimation for potential abnormal behavior and accidental event detection, as evidenced with our experimental tests. Furthermore, based on the reliable head (face) tacking, we have applied a super-resolution algorithm to enhance the face resolution for improved human face recognition performance.

  6. The evolution of body size and shape in the human career

    PubMed Central

    Grabowski, Mark; Hatala, Kevin G.; Richmond, Brian G.

    2016-01-01

    Body size is a fundamental biological property of organisms, and documenting body size variation in hominin evolution is an important goal of palaeoanthropology. Estimating body mass appears deceptively simple but is laden with theoretical and pragmatic assumptions about best predictors and the most appropriate reference samples. Modern human training samples with known masses are arguably the ‘best’ for estimating size in early bipedal hominins such as the australopiths and all members of the genus Homo, but it is not clear if they are the most appropriate priors for reconstructing the size of the earliest putative hominins such as Orrorin and Ardipithecus. The trajectory of body size evolution in the early part of the human career is reviewed here and found to be complex and nonlinear. Australopith body size varies enormously across both space and time. The pre-erectus early Homo fossil record from Africa is poor and dominated by relatively small-bodied individuals, implying that the emergence of the genus Homo is probably not linked to an increase in body size or unprecedented increases in size variation. Body size differences alone cannot explain the observed variation in hominin body shape, especially when examined in the context of small fossil hominins and pygmy modern humans. This article is part of the themed issue ‘Major transitions in human evolution’. PMID:27298459

  7. The evolution of body size and shape in the human career.

    PubMed

    Jungers, William L; Grabowski, Mark; Hatala, Kevin G; Richmond, Brian G

    2016-07-05

    Body size is a fundamental biological property of organisms, and documenting body size variation in hominin evolution is an important goal of palaeoanthropology. Estimating body mass appears deceptively simple but is laden with theoretical and pragmatic assumptions about best predictors and the most appropriate reference samples. Modern human training samples with known masses are arguably the 'best' for estimating size in early bipedal hominins such as the australopiths and all members of the genus Homo, but it is not clear if they are the most appropriate priors for reconstructing the size of the earliest putative hominins such as Orrorin and Ardipithecus The trajectory of body size evolution in the early part of the human career is reviewed here and found to be complex and nonlinear. Australopith body size varies enormously across both space and time. The pre-erectus early Homo fossil record from Africa is poor and dominated by relatively small-bodied individuals, implying that the emergence of the genus Homo is probably not linked to an increase in body size or unprecedented increases in size variation. Body size differences alone cannot explain the observed variation in hominin body shape, especially when examined in the context of small fossil hominins and pygmy modern humans.This article is part of the themed issue 'Major transitions in human evolution'. © 2016 The Author(s).

  8. A method for direct measurement of the first-order mass moments of human body segments.

    PubMed

    Fujii, Yusaku; Shimada, Kazuhito; Maru, Koichi; Ozawa, Junichi; Lu, Rong-Sheng

    2010-01-01

    We propose a simple and direct method for measuring the first-order mass moment of a human body segment. With the proposed method, the first-order mass moment of the body segment can be directly measured by using only one precision scale and one digital camera. In the dummy mass experiment, the relative standard uncertainty of a single set of measurements of the first-order mass moment is estimated to be 1.7%. The measured value will be useful as a reference for evaluating the uncertainty of the body segment inertial parameters (BSPs) estimated using an indirect method.

  9. Modal Damping Ratio and Optimal Elastic Moduli of Human Body Segments for Anthropometric Vibratory Model of Standing Subjects.

    PubMed

    Gupta, Manoj; Gupta, T C

    2017-10-01

    The present study aims to accurately estimate inertial, physical, and dynamic parameters of human body vibratory model consistent with physical structure of the human body that also replicates its dynamic response. A 13 degree-of-freedom (DOF) lumped parameter model for standing person subjected to support excitation is established. Model parameters are determined from anthropometric measurements, uniform mass density, elastic modulus of individual body segments, and modal damping ratios. Elastic moduli of ellipsoidal body segments are initially estimated by comparing stiffness of spring elements, calculated from a detailed scheme, and values available in literature for same. These values are further optimized by minimizing difference between theoretically calculated platform-to-head transmissibility ratio (TR) and experimental measurements. Modal damping ratios are estimated from experimental transmissibility response using two dominant peaks in the frequency range of 0-25 Hz. From comparison between dynamic response determined form modal analysis and experimental results, a set of elastic moduli for different segments of human body and a novel scheme to determine modal damping ratios from TR plots, are established. Acceptable match between transmissibility values calculated from the vibratory model and experimental measurements for 50th percentile U.S. male, except at very low frequencies, establishes the human body model developed. Also, reasonable agreement obtained between theoretical response curve and experimental response envelop for average Indian male, affirms the technique used for constructing vibratory model of a standing person. Present work attempts to develop effective technique for constructing subject specific damped vibratory model based on its physical measurements.

  10. Influence of the model's degree of freedom on human body dynamics identification.

    PubMed

    Maita, Daichi; Venture, Gentiane

    2013-01-01

    In fields of sports and rehabilitation, opportunities of using motion analysis of the human body have dramatically increased. To analyze the motion dynamics, a number of subject specific parameters and measurements are required. For example the contact forces measurement and the inertial parameters of each segment of the human body are necessary to compute the joint torques. In this study, in order to perform accurate dynamic analysis we propose to identify the inertial parameters of the human body and to evaluate the influence of the model's number of degrees of freedom (DoF) on the results. We use a method to estimate the inertial parameters without torque sensor, using generalized coordinates of the base link, joint angles and external forces information. We consider a 34DoF model, a 58DoF model, as well as the case when the human is manipulating a tool (here a tennis racket). We compare the obtained in results in terms of contact force estimation.

  11. Body mass and stature estimation based on the first metatarsal in humans.

    PubMed

    De Groote, Isabelle; Humphrey, Louise T

    2011-04-01

    Archaeological assemblages often lack the complete long bones needed to estimate stature and body mass. The most accurate estimates of body mass and stature are produced using femoral head diameter and femur length. Foot bones including the first metatarsal preserve relatively well in a range of archaeological contexts. In this article we present regression equations using the first metatarsal to estimate femoral head diameter, femoral length, and body mass in a diverse human sample. The skeletal sample comprised 87 individuals (Andamanese, Australasians, Africans, Native Americans, and British). Results show that all first metatarsal measurements correlate moderately to highly (r = 0.62-0.91) with femoral head diameter and length. The proximal articular dorsoplantar diameter is the best single measurement to predict both femoral dimensions. Percent standard errors of the estimate are below 5%. Equations using two metatarsal measurements show a small increase in accuracy. Direct estimations of body mass (calculated from measured femoral head diameter using previously published equations) have an error of just over 7%. No direct stature estimation equations were derived due to the varied linear body proportions represented in the sample. The equations were tested on a sample of 35 individuals from Christ Church Spitalfields. Percentage differences in estimated and measured femoral head diameter and length were less than 1%. This study demonstrates that it is feasible to use the first metatarsal in the estimation of body mass and stature. The equations presented here are particularly useful for assemblages where the long bones are either missing or fragmented, and enable estimation of these fundamental population parameters in poorly preserved assemblages. Copyright © 2011 Wiley-Liss, Inc.

  12. Numerical compliance testing of human exposure to electromagnetic radiation from smart-watches.

    PubMed

    Hong, Seon-Eui; Lee, Ae-Kyoung; Kwon, Jong-Hwa; Pack, Jeong-Ki

    2016-10-07

    In this study, we investigated the electromagnetic dosimetry for smart-watches. At present, the standard for compliance testing of body-mounted and handheld devices specifies the use of a flat phantom to provide conservative estimates of the peak spatial-averaged specific absorption rate (SAR). This means that the estimated SAR using a flat phantom should be higher than the SAR in the exposure part of an anatomical human-body model. To verify this, we numerically calculated the SAR for a flat phantom and compared it with the numerical calculation of the SAR for four anatomical human-body models of different ages. The numerical analysis was performed using the finite difference time domain method (FDTD). The smart-watch models were used in the three antennas: the shorted planar inverted-F antenna (PIFA), loop antenna, and monopole antenna. Numerical smart-watch models were implemented for cellular commutation and wireless local-area network operation at 835, 1850, and 2450 MHz. The peak spatial-averaged SARs of the smart-watch models are calculated for the flat phantom and anatomical human-body model for the wrist-worn and next to mouth positions. The results show that the flat phantom does not provide a consistent conservative SAR estimate. We concluded that the difference in the SAR results between an anatomical human-body model and a flat phantom can be attributed to the different phantom shapes and tissue structures.

  13. Numerical compliance testing of human exposure to electromagnetic radiation from smart-watches

    NASA Astrophysics Data System (ADS)

    Hong, Seon-Eui; Lee, Ae-Kyoung; Kwon, Jong-Hwa; Pack, Jeong-Ki

    2016-10-01

    In this study, we investigated the electromagnetic dosimetry for smart-watches. At present, the standard for compliance testing of body-mounted and handheld devices specifies the use of a flat phantom to provide conservative estimates of the peak spatial-averaged specific absorption rate (SAR). This means that the estimated SAR using a flat phantom should be higher than the SAR in the exposure part of an anatomical human-body model. To verify this, we numerically calculated the SAR for a flat phantom and compared it with the numerical calculation of the SAR for four anatomical human-body models of different ages. The numerical analysis was performed using the finite difference time domain method (FDTD). The smart-watch models were used in the three antennas: the shorted planar inverted-F antenna (PIFA), loop antenna, and monopole antenna. Numerical smart-watch models were implemented for cellular commutation and wireless local-area network operation at 835, 1850, and 2450 MHz. The peak spatial-averaged SARs of the smart-watch models are calculated for the flat phantom and anatomical human-body model for the wrist-worn and next to mouth positions. The results show that the flat phantom does not provide a consistent conservative SAR estimate. We concluded that the difference in the SAR results between an anatomical human-body model and a flat phantom can be attributed to the different phantom shapes and tissue structures.

  14. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition

    PubMed Central

    Wang, ZiMian; Heymsfield, Steven B; Chen, Zhao; Zhu, Shankuan; Pierson, Richard N

    2010-01-01

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated RST value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the RST concept depends on the mass of each major element in the human body. The DXA RST values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA RST value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body 40K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the RST values. The DXA RST values were strongly associated with the RST values predicted from elemental content (r = 0.976, P < 0.001), although there was a tendency for the elemental-predicted RST to systematically exceed the DXA-measured RST (mean ± SD, 1.389 ± 0.024 versus 1.341 ± 0.024). DXA-estimated %fat was strongly associated with 5C %fat (24.4 ± 12.0% versus 24.9 ± 11.1%, r = 0.983, P < 0.001). DXA RST evaluated by in vivo elemental composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat. PMID:20393230

  15. Updates to Blast Injury Criteria Models for Nuclear Casualty Estimation

    DTIC Science & Technology

    2015-12-01

    the likelihood of blast-related injury use a two-step process. First, the maximum velocity obtained by the human body or secondary missile is determined...the human body . Secondary injuries are caused by missiles that are accelerated by the blast wave. Tertiary injuries are caused by the acceleration of...the human body and the ensuing deceleration. In this work, we focus on secondary and tertiary injuries. Because of the dramatic effects experienced

  16. Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing

    PubMed Central

    Sabatini, Angelo Maria

    2011-01-01

    User-worn sensing units composed of inertial and magnetic sensors are becoming increasingly popular in various domains, including biomedical engineering, robotics, virtual reality, where they can also be applied for real-time tracking of the orientation of human body parts in the three-dimensional (3D) space. Although they are a promising choice as wearable sensors under many respects, the inertial and magnetic sensors currently in use offer measuring performance that are critical in order to achieve and maintain accurate 3D-orientation estimates, anytime and anywhere. This paper reviews the main sensor fusion and filtering techniques proposed for accurate inertial/magnetic orientation tracking of human body parts; it also gives useful recipes for their actual implementation. PMID:22319365

  17. Estimating three-dimensional orientation of human body parts by inertial/magnetic sensing.

    PubMed

    Sabatini, Angelo Maria

    2011-01-01

    User-worn sensing units composed of inertial and magnetic sensors are becoming increasingly popular in various domains, including biomedical engineering, robotics, virtual reality, where they can also be applied for real-time tracking of the orientation of human body parts in the three-dimensional (3D) space. Although they are a promising choice as wearable sensors under many respects, the inertial and magnetic sensors currently in use offer measuring performance that are critical in order to achieve and maintain accurate 3D-orientation estimates, anytime and anywhere. This paper reviews the main sensor fusion and filtering techniques proposed for accurate inertial/magnetic orientation tracking of human body parts; it also gives useful recipes for their actual implementation.

  18. Six degree-of-freedom analysis of hip, knee, ankle and foot provides updated understanding of biomechanical work during human walking.

    PubMed

    Zelik, Karl E; Takahashi, Kota Z; Sawicki, Gregory S

    2015-03-01

    Measuring biomechanical work performed by humans and other animals is critical for understanding muscle-tendon function, joint-specific contributions and energy-saving mechanisms during locomotion. Inverse dynamics is often employed to estimate joint-level contributions, and deformable body estimates can be used to study work performed by the foot. We recently discovered that these commonly used experimental estimates fail to explain whole-body energy changes observed during human walking. By re-analyzing previously published data, we found that about 25% (8 J) of total positive energy changes of/about the body's center-of-mass and >30% of the energy changes during the Push-off phase of walking were not explained by conventional joint- and segment-level work estimates, exposing a gap in our fundamental understanding of work production during gait. Here, we present a novel Energy-Accounting analysis that integrates various empirical measures of work and energy to elucidate the source of unexplained biomechanical work. We discovered that by extending conventional 3 degree-of-freedom (DOF) inverse dynamics (estimating rotational work about joints) to 6DOF (rotational and translational) analysis of the hip, knee, ankle and foot, we could fully explain the missing positive work. This revealed that Push-off work performed about the hip may be >50% greater than conventionally estimated (9.3 versus 6.0 J, P=0.0002, at 1.4 m s(-1)). Our findings demonstrate that 6DOF analysis (of hip-knee-ankle-foot) better captures energy changes of the body than more conventional 3DOF estimates. These findings refine our fundamental understanding of how work is distributed within the body, which has implications for assistive technology, biomechanical simulations and potentially clinical treatment. © 2015. Published by The Company of Biologists Ltd.

  19. How much more would KNM-WT 15000 have grown?

    PubMed

    Ruff, Christopher B; Burgess, M Loring

    2015-03-01

    Because of its completeness, the juvenile Homo ergaster/erectus KNM-WT 15000 has played an important role in studies of the evolution of body form in Homo. Early attempts to estimate his adult body size used modern human growth models. However, more recent evidence, particularly from the dentition, suggests that he may have had a more chimpanzee-like growth trajectory. Here we re-estimate his adult stature and body mass using ontogenetic data derived from four African ape taxa: Pan troglodytes troglodytes, Pan troglodytes schweinfurthii, Pan paniscus, and Gorilla gorilla gorilla. The average percentage change in femoral and tibial lengths and femoral head breadth between individuals at the same stage of dental development as KNM-WT 15000 - eruption of M2s but not M3s - and adult individuals with fully fused long bone epiphyses, was determined. Results were then applied to KNM-WT 15000, and his adult size estimated from skeletal dimensions using modern human prediction formulae. Using this approach, adult stature best estimates of 176-180 cm and body mass best estimates of 80-83 kg were obtained. These estimates are close to those estimated directly from longitudinal changes in body length and body mass between 8 and 12 years of age in chimpanzees, the suggested chronological equivalent to KNM-WT 15000's remaining growth period. Thus, even using an African ape growth model, it is likely that KNM-WT 15000 would have attained close to 180 cm in stature (without a slight reduction for his lower cranial height) and 80 kg in body mass as an adult. Other evidence from the East African Early Pleistocene indicates that KNM-WT 15000 was not unusually large-bodied for his time period. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Human body surface area database and estimation formula.

    PubMed

    Yu, Chi-Yuang; Lin, Ching-Hua; Yang, Yi-Hsueh

    2010-08-01

    This study established human body surface area (BSA) database and estimation formula based on three-dimensional (3D) scanned data. For each gender, 135 subjects were drawn. The sampling was stratified in five stature heights and three body weights according to a previous survey. The 3D body surface shape was measured using an innovated 3D body scanner and a high resolution hand/foot scanner, the total body surface area (BSA) and segmental body surface area (SBSA) were computed based on the summation of every tiny triangular area of triangular meshes of the scanned surface; and the accuracy of BSA measurement is below 1%. The results of BSA and sixteen SBSAs were tabulated in fifteen strata for the Male, the Female and the Total (two genders combined). The %SBSA data was also used to revise new Lund and Browder Charts. The comparison of BSA shows that the BSA of this study is comparable with the Du Bois and Du Bois' but smaller than that of Tikuisis et al. The difference might be attributed to body size difference between the samples. The comparison of SBSA shows that the differences of SBSA between this study and the Lund and Browder Chart range between 0.00% and 2.30%. A new BSA estimation formula, BSA=71.3989 x H(.7437) x W(.4040), was obtained. An accuracy test showed that this formula has smaller estimation error than that of the Du Bois and Du Bois'; and significantly better than other BSA estimation formulae.

  1. Human adaptations for the visual assessment of strength and fighting ability from the body and face

    PubMed Central

    Sell, Aaron; Cosmides, Leda; Tooby, John; Sznycer, Daniel; von Rueden, Christopher; Gurven, Michael

    2008-01-01

    Selection in species with aggressive social interactions favours the evolution of cognitive mechanisms for assessing physical formidability (fighting ability or resource-holding potential). The ability to accurately assess formidability in conspecifics has been documented in a number of non-human species, but has not been demonstrated in humans. Here, we report tests supporting the hypothesis that the human cognitive architecture includes mechanisms that assess fighting ability—mechanisms that focus on correlates of upper-body strength. Across diverse samples of targets that included US college students, Bolivian horticulturalists and Andean pastoralists, subjects in the US were able to accurately estimate the physical strength of male targets from photos of their bodies and faces. Hierarchical linear modelling shows that subjects were extracting cues of strength that were largely independent of height, weight and age, and that corresponded most strongly to objective measures of upper-body strength—even when the face was all that was available for inspection. Estimates of women's strength were less accurate, but still significant. These studies are the first empirical demonstration that, for humans, judgements of strength and judgements of fighting ability not only track each other, but accurately track actual upper-body strength. PMID:18945661

  2. CT scan range estimation using multiple body parts detection: let PACS learn the CT image content.

    PubMed

    Wang, Chunliang; Lundström, Claes

    2016-02-01

    The aim of this study was to develop an efficient CT scan range estimation method that is based on the analysis of image data itself instead of metadata analysis. This makes it possible to quantitatively compare the scan range of two studies. In our study, 3D stacks are first projected to 2D coronal images via a ray casting-like process. Trained 2D body part classifiers are then used to recognize different body parts in the projected image. The detected candidate regions go into a structure grouping process to eliminate false-positive detections. Finally, the scale and position of the patient relative to the projected figure are estimated based on the detected body parts via a structural voting. The start and end lines of the CT scan are projected to a standard human figure. The position readout is normalized so that the bottom of the feet represents 0.0, and the top of the head is 1.0. Classifiers for 18 body parts were trained using 184 CT scans. The final application was tested on 136 randomly selected heterogeneous CT scans. Ground truth was generated by asking two human observers to mark the start and end positions of each scan on the standard human figure. When compared with the human observers, the mean absolute error of the proposed method is 1.2% (max: 3.5%) and 1.6% (max: 5.4%) for the start and end positions, respectively. We proposed a scan range estimation method using multiple body parts detection and relative structure position analysis. In our preliminary tests, the proposed method delivered promising results.

  3. A painless and constraint-free method to estimate viscoelastic passive dynamics of limbs' joints to support diagnosis of neuromuscular diseases.

    PubMed

    Venture, Gentiane; Nakamura, Yoshihiko; Yamane, Katsu; Hirashima, Masaya

    2007-01-01

    Though seldom identified, the human joints dynamics is important in the fields of medical robotics and medical research. We present a general solution to estimate in-vivo and simultaneously the passive dynamics of the human limbs' joints. It is based on the use of the multi-body description of the human body and its kinematics and dynamics computations. The linear passive joint dynamics of the shoulders and the elbows: stiffness, viscosity and friction, is estimated simultaneously using the linear least squares method. Acquisition of movements is achieved with an optical motion capture studio on one examinee during the clinical diagnosis of neuromuscular diseases. Experimental results are given and discussed.

  4. Human Pose Estimation from Monocular Images: A Comprehensive Survey

    PubMed Central

    Gong, Wenjuan; Zhang, Xuena; Gonzàlez, Jordi; Sobral, Andrews; Bouwmans, Thierry; Tu, Changhe; Zahzah, El-hadi

    2016-01-01

    Human pose estimation refers to the estimation of the location of body parts and how they are connected in an image. Human pose estimation from monocular images has wide applications (e.g., image indexing). Several surveys on human pose estimation can be found in the literature, but they focus on a certain category; for example, model-based approaches or human motion analysis, etc. As far as we know, an overall review of this problem domain has yet to be provided. Furthermore, recent advancements based on deep learning have brought novel algorithms for this problem. In this paper, a comprehensive survey of human pose estimation from monocular images is carried out including milestone works and recent advancements. Based on one standard pipeline for the solution of computer vision problems, this survey splits the problem into several modules: feature extraction and description, human body models, and modeling methods. Problem modeling methods are approached based on two means of categorization in this survey. One way to categorize includes top-down and bottom-up methods, and another way includes generative and discriminative methods. Considering the fact that one direct application of human pose estimation is to provide initialization for automatic video surveillance, there are additional sections for motion-related methods in all modules: motion features, motion models, and motion-based methods. Finally, the paper also collects 26 publicly available data sets for validation and provides error measurement methods that are frequently used. PMID:27898003

  5. The perceptual homunculus: the perception of the relative proportions of the human body.

    PubMed

    Linkenauger, Sally A; Wong, Hong Yu; Geuss, Michael; Stefanucci, Jeanine K; McCulloch, Kathleen C; Bülthoff, Heinrich H; Mohler, Betty J; Proffitt, Dennis R

    2015-02-01

    Given that observing one's body is ubiquitous in experience, it is natural to assume that people accurately perceive the relative sizes of their body parts. This assumption is mistaken. In a series of studies, we show that there are dramatic systematic distortions in the perception of bodily proportions, as assessed by visual estimation tasks, where participants were asked to compare the lengths of two body parts. These distortions are not evident when participants estimate the extent of a body part relative to a noncorporeal object or when asked to estimate noncorporal objects that are the same length as their body parts. Our results reveal a radical asymmetry in the perception of corporeal and noncorporeal relative size estimates. Our findings also suggest that people visually perceive the relative size of their body parts as a function of each part's relative tactile sensitivity and physical size.

  6. Quantitative body DW-MRI biomarkers uncertainty estimation using unscented wild-bootstrap.

    PubMed

    Freiman, M; Voss, S D; Mulkern, R V; Perez-Rossello, J M; Warfield, S K

    2011-01-01

    We present a new method for the uncertainty estimation of diffusion parameters for quantitative body DW-MRI assessment. Diffusion parameters uncertainty estimation from DW-MRI is necessary for clinical applications that use these parameters to assess pathology. However, uncertainty estimation using traditional techniques requires repeated acquisitions, which is undesirable in routine clinical use. Model-based bootstrap techniques, for example, assume an underlying linear model for residuals rescaling and cannot be utilized directly for body diffusion parameters uncertainty estimation due to the non-linearity of the body diffusion model. To offset this limitation, our method uses the Unscented transform to compute the residuals rescaling parameters from the non-linear body diffusion model, and then applies the wild-bootstrap method to infer the body diffusion parameters uncertainty. Validation through phantom and human subject experiments shows that our method identify the regions with higher uncertainty in body DWI-MRI model parameters correctly with realtive error of -36% in the uncertainty values.

  7. Estimation of body surface area in the musk shrew ( Suncus murinus): a small animal for testing chemotherapy-induced emesis.

    PubMed

    Eiseman, Julie L; Sciullo, Michael; Wang, Hong; Beumer, Jan H; Horn, Charles C

    2017-10-01

    Several cancer chemotherapies cause nausea and vomiting, which can be dose-limiting. Musk shrews are used as preclinical models for chemotherapy-induced emesis and for antiemetic effectiveness. Unlike rats and mice, shrews possess a vomiting reflex and demonstrate an emetic profile similar to humans, including acute and delayed phases. As with most animals, dosing of shrews is based on body weight, while translation of such doses to clinically equivalent exposure requires doses based on body surface area. In the current study body surface area in musk shrews was directly assessed to determine the Meeh constant (K m ) conversion factor (female = 9.97, male = 9.10), allowing estimation of body surface area based on body weight. These parameters can be used to determine dosing strategies for shrew studies that model human drug exposures, particularly for investigating the emetic liability of cancer chemotherapeutic agents.

  8. A Novel Field-Circuit FEM Modeling and Channel Gain Estimation for Galvanic Coupling Real IBC Measurements.

    PubMed

    Gao, Yue-Ming; Wu, Zhu-Mei; Pun, Sio-Hang; Mak, Peng-Un; Vai, Mang-I; Du, Min

    2016-04-02

    Existing research on human channel modeling of galvanic coupling intra-body communication (IBC) is primarily focused on the human body itself. Although galvanic coupling IBC is less disturbed by external influences during signal transmission, there are inevitable factors in real measurement scenarios such as the parasitic impedance of electrodes, impedance matching of the transceiver, etc. which might lead to deviations between the human model and the in vivo measurements. This paper proposes a field-circuit finite element method (FEM) model of galvanic coupling IBC in a real measurement environment to estimate the human channel gain. First an anisotropic concentric cylinder model of the electric field intra-body communication for human limbs was developed based on the galvanic method. Then the electric field model was combined with several impedance elements, which were equivalent in terms of parasitic impedance of the electrodes, input and output impedance of the transceiver, establishing a field-circuit FEM model. The results indicated that a circuit module equivalent to external factors can be added to the field-circuit model, which makes this model more complete, and the estimations based on the proposed field-circuit are in better agreement with the corresponding measurement results.

  9. Whole-Body Human Inverse Dynamics with Distributed Micro-Accelerometers, Gyros and Force Sensing †

    PubMed Central

    Latella, Claudia; Kuppuswamy, Naveen; Romano, Francesco; Traversaro, Silvio; Nori, Francesco

    2016-01-01

    Human motion tracking is a powerful tool used in a large range of applications that require human movement analysis. Although it is a well-established technique, its main limitation is the lack of estimation of real-time kinetics information such as forces and torques during the motion capture. In this paper, we present a novel approach for a human soft wearable force tracking for the simultaneous estimation of whole-body forces along with the motion. The early stage of our framework encompasses traditional passive marker based methods, inertial and contact force sensor modalities and harnesses a probabilistic computational technique for estimating dynamic quantities, originally proposed in the domain of humanoid robot control. We present experimental analysis on subjects performing a two degrees-of-freedom bowing task, and we estimate the motion and kinetics quantities. The results demonstrate the validity of the proposed method. We discuss the possible use of this technique in the design of a novel soft wearable force tracking device and its potential applications. PMID:27213394

  10. Control of the seven-degree-of-freedom upper limb exoskeleton for an improved human-robot interface

    NASA Astrophysics Data System (ADS)

    Kim, Hyunchul; Kim, Jungsuk

    2017-04-01

    This study analyzes a practical scheme for controlling an exoskeleton robot with seven degrees of freedom (DOFs) that supports natural movements of the human arm. A redundant upper limb exoskeleton robot with seven DOFs is mechanically coupled to the human body such that it becomes a natural extension of the body. If the exoskeleton robot follows the movement of the human body synchronously, the energy exchange between the human and the robot will be reduced significantly. In order to achieve this, the redundancy of the human arm, which is represented by the swivel angle, should be resolved using appropriate constraints and applied to the robot. In a redundant 7-DOF upper limb exoskeleton, the pseudoinverse of the Jacobian with secondary objective functions is widely used to resolve the redundancy that defines the desired joint angles. A secondary objective function requires the desired joint angles for the movement of the human arm, and the angles are estimated by maximizing the projection of the longest principle axis of the manipulability ellipsoid for the human arm onto the virtual destination toward the head region. Then, they are fed into the muscle model with a relative damping to achieve more realistic robot-arm movements. Various natural arm movements are recorded using a motion capture system, and the actual swivel-angle is compared to that estimated using the proposed swivel angle estimation algorithm. The results indicate that the proposed algorithm provides a precise reference for estimating the desired joint angle with an error less than 5°.

  11. Investigation of human body potential measured by a non-contact measuring system.

    PubMed

    Ichikawa, Norimitsu

    2016-12-07

    A human body is occasionally electrified in a room. This charged object will be a source of electrostatic accidents, including the malfunction of electronic equipment. Hence, prevention of these accidents is required. Accidents occasionally occur, even though antistatic clothes and shoes are used. One of the causes for these accidents is that there is a lack of the preventive measures. This situation occurs when using, for example, unconductive wax. In this study, human body potential (voltage) is measured using a non-contact measuring system. An investigation of the human body's voltage when using this system is conducted. The result demonstrates that the voltage of a human body wearing antistatic clothes and shoes or light clothes and slippers exceeds a malfunctioning voltage of a microelectronics device when the body walks on floors. Thus, accidents may occur even if a human body wearing the antistatic clothes walks on flooring. These results will be useful in estimating determination whether electrostatic accidents occur or not.

  12. Analysis of Timing Control Mechanism of Utterance and Body Motion Using Dialogue between Human and Communication Robot

    NASA Astrophysics Data System (ADS)

    Takasugi, Shoji; Yamamoto, Tomohito; Muto, Yumiko; Abe, Hiroyuki; Miyake, Yoshihiro

    The purpose of this study is to clarify the effects of timing control of utterance and body motion in human-robot interaction. Our previous study has already revealed the correlation of timing of utterance and body motion in human-human communication. Here we proposed a timing control model based on our previous research and estimated its influence to realize human-like communication using a questionnaire method. The results showed that the difference of effectiveness between the communication with the timing control model and that without it was observed. In addition, elderly people evaluated the communication with timing control much higher than younger people. These results show not only the importance of timing control of utterance and body motion in human communication but also its effectiveness for realizing human-like human-robot interaction.

  13. Simultaneous and multi-point measurement of ammonia emanating from human skin surface for the estimation of whole body dermal emission rate.

    PubMed

    Furukawa, Shota; Sekine, Yoshika; Kimura, Keita; Umezawa, Kazuo; Asai, Satomi; Miyachi, Hayato

    2017-05-15

    Ammonia is one of the members of odor gases and a possible source of odor in indoor environment. However, little has been known on the actual emission rate of ammonia from the human skin surface. Then, this study aimed to estimate the whole-body dermal emission rate of ammonia by simultaneous and multi-point measurement of emission fluxes of ammonia employing a passive flux sampler - ion chromatography system. Firstly, the emission fluxes of ammonia were non-invasively measured for ten volunteers at 13 sampling positions set in 13 anatomical regions classified by Kurazumi et al. The measured emission fluxes were then converted to partial emission rates using the surface body areas estimated by weights and heights of volunteers and partial rates of 13 body regions. Subsequent summation of the partial emission rates provided the whole body dermal emission rate of ammonia. The results ranged from 2.9 to 12mgh -1 with an average of 5.9±3.2mgh -1 per person for the ten healthy young volunteers. The values were much greater than those from human breath, and thus the dermal emission of ammonia was found more significant odor source than the breath exhalation in indoor environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. A learning-based markerless approach for full-body kinematics estimation in-natura from a single image.

    PubMed

    Drory, Ami; Li, Hongdong; Hartley, Richard

    2017-04-11

    We present a supervised machine learning approach for markerless estimation of human full-body kinematics for a cyclist from an unconstrained colour image. This approach is motivated by the limitations of existing marker-based approaches restricted by infrastructure, environmental conditions, and obtrusive markers. By using a discriminatively learned mixture-of-parts model, we construct a probabilistic tree representation to model the configuration and appearance of human body joints. During the learning stage, a Structured Support Vector Machine (SSVM) learns body parts appearance and spatial relations. In the testing stage, the learned models are employed to recover body pose via searching in a test image over a pyramid structure. We focus on the movement modality of cycling to demonstrate the efficacy of our approach. In natura estimation of cycling kinematics using images is challenging because of human interaction with a bicycle causing frequent occlusions. We make no assumptions in relation to the kinematic constraints of the model, nor the appearance of the scene. Our technique finds multiple quality hypotheses for the pose. We evaluate the precision of our method on two new datasets using loss functions. Our method achieves a score of 91.1 and 69.3 on mean Probability of Correct Keypoint (PCK) measure and 88.7 and 66.1 on the Average Precision of Keypoints (APK) measure for the frontal and sagittal datasets respectively. We conclude that our method opens new vistas to robust user-interaction free estimation of full body kinematics, a prerequisite to motion analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Understanding Differences in the Body Burden–Age Relationships of Bioaccumulating Contaminants Based on Population Cross Sections versus Individuals

    PubMed Central

    Quinn, Cristina L.

    2012-01-01

    Background: Body burdens of persistent bioaccumulative contaminants estimated from the cross-sectional biomonitoring of human populations are often plotted against age. Such relationships have previously been assumed to reflect the role of age in bioaccumulation. Objectives: We used a mechanistic modeling approach to reproduce concentration-versus-age relationships and investigate factors that influence them. Method: CoZMoMAN is an environmental fate and human food chain bioaccumulation model that estimates time trends in human body burdens in response to time-variant environmental emissions. Trends of polychlorinated biphenyl (PCB) congener 153 concentrations versus age for population cross sections were estimated using simulated longitudinal data for individual women born at different times. The model was also used to probe the influence of partitioning and degradation properties, length of emissions, and model assumptions regarding lipid content and liver metabolism on concentration–age trends of bioaccumulative and persistent contaminants. Results: Body burden–age relationships for population cross sections and individuals over time are not equivalent. The time lapse between the peak in emissions and sample collection for biomonitoring is the most influential factor controlling the shape of concentration–age trends for chemicals with human metabolic half-lives longer than 1 year. Differences in observed concentration–age trends for PCBs and polybrominated diphenyl ethers are consistent with differences in emission time trends and human metabolic half-lives. Conclusions: Bioaccumulation does not monotonically increase with age. Our model suggests that the main predictors of cross-sectional body burden trends with age are the amount of time elapsed after peak emissions and the human metabolic and environmental degradation rates. PMID:22472302

  16. Identification and experimental validation of damping ratios of different human body segments through anthropometric vibratory model in standing posture.

    PubMed

    Gupta, T C

    2007-08-01

    A 15 degrees of freedom lumped parameter vibratory model of human body is developed, for vertical mode vibrations, using anthropometric data of the 50th percentile US male. The mass and stiffness of various segments are determined from the elastic modulii of bones and tissues and from the anthropometric data available, assuming the shape of all the segments is ellipsoidal. The damping ratio of each segment is estimated on the basis of the physical structure of the body in a particular posture. Damping constants of various segments are calculated from these damping ratios. The human body is modeled as a linear spring-mass-damper system. The optimal values of the damping ratios of the body segments are estimated, for the 15 degrees of freedom model of the 50th percentile US male, by comparing the response of the model with the experimental response. Formulating a similar vibratory model of the 50th percentile Indian male and comparing the frequency response of the model with the experimental response of the same group of subjects validate the modeling procedure. A range of damping ratios has been considered to develop a vibratory model, which can predict the vertical harmonic response of the human body.

  17. Dosimetry of 64Cu-DOTA-AE105, a PET tracer for uPAR imaging.

    PubMed

    Persson, Morten; El Ali, Henrik H; Binderup, Tina; Pfeifer, Andreas; Madsen, Jacob; Rasmussen, Palle; Kjaer, Andreas

    2014-03-01

    (64)Cu-DOTA-AE105 is a novel positron emission tomography (PET) tracer specific to the human urokinase-type plasminogen activator receptor (uPAR). In preparation of using this tracer in humans, as a new promising method to distinguish between indolent and aggressive cancers, we have performed PET studies in mice to evaluate the in vivo biodistribution and estimate human dosimetry of (64)Cu-DOTA-AE105. Five mice received iv tail injection of (64)Cu-DOTA-AE105 and were PET/CT scanned 1, 4.5 and 22 h post injection. Volume-of-interest (VOI) were manually drawn on the following organs: heart, lung, liver, kidney, spleen, intestine, muscle, bone and bladder. The activity concentrations in the mentioned organs [%ID/g] were used for the dosimetry calculation. The %ID/g of each organ at 1, 4.5 and 22 h was scaled to human value based on a difference between organ and body weights. The scaled values were then exported to OLINDA software for computation of the human absorbed doses. The residence times as well as effective dose equivalent for male and female could be obtained for each organ. To validate this approach, of human projection using mouse data, five mice received iv tail injection of another (64)Cu-DOTA peptide-based tracer, (64)Cu-DOTA-TATE, and underwent same procedure as just described. The human dosimetry estimates were then compared with observed human dosimetry estimate recently found in a first-in-man study using (64)Cu-DOTA-TATE. Human estimates of (64)Cu-DOTA-AE105 revealed the heart wall to receive the highest dose (0.0918 mSv/MBq) followed by the liver (0.0815 mSv/MBq), All other organs/tissue were estimated to receive doses in the range of 0.02-0.04 mSv/MBq. The mean effective whole-body dose of (64)Cu-DOTA-AE105 was estimated to be 0.0317 mSv/MBq. Relatively good correlation between human predicted and observed dosimetry estimates for (64)Cu-DOTA-TATE was found. Importantly, the effective whole body dose was predicted with very high precision (predicted value: 0.0252 mSv/Mbq, Observed value: 0.0315 mSv/MBq) thus validating our approach for human dosimetry estimation. Favorable dosimetry estimates together with previously reported uPAR PET data fully support human testing of (64)Cu-DOTA-AE105. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition.

    PubMed

    Wang, ZiMian; Heymsfield, Steven B; Chen, Zhao; Zhu, Shankuan; Pierson, Richard N

    2010-05-07

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R(ST) value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R(ST) concept depends on the mass of each major element in the human body. The DXA R(ST) values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA R(ST) value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body (40)K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the R(ST) values. The DXA R(ST) values were strongly associated with the R(ST) values predicted from elemental content (r = 0.976, P < 0.001), although there was a tendency for the elemental-predicted R(ST) to systematically exceed the DXA-measured R(ST) (mean +/- SD, 1.389 +/- 0.024 versus 1.341 +/- 0.024). DXA-estimated %fat was strongly associated with 5C %fat (24.4 +/- 12.0% versus 24.9 +/- 11.1%, r = 0.983, P < 0.001). DXA R(ST) is evaluated by in vivo elemental composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat.

  19. Direct comparison of radiation dosimetry of six PET tracers using human whole-body imaging and murine biodistribution studies.

    PubMed

    Sakata, Muneyuki; Oda, Keiichi; Toyohara, Jun; Ishii, Kenji; Nariai, Tadashi; Ishiwata, Kiichi

    2013-04-01

    We investigated the whole-body biodistributions and radiation dosimetry of five (11)C-labeled and one (18)F-labeled radiotracers in human subjects, and compared the results to those obtained from murine biodistribution studies. The radiotracers investigated were (11)C-SA4503, (11)C-MPDX, (11)C-TMSX, (11)C-CHIBA-1001, (11)C-4DST, and (18)F-FBPA. Dynamic whole-body positron emission tomography (PET) was performed in three human subjects after a single bolus injection of each radiotracer. Emission scans were collected in two-dimensional mode in five bed positions. Regions of interest were placed over organs identified in reconstructed PET images. The OLINDA program was used to estimate radiation doses from the number of disintegrations of these source organs. These results were compared with the predicted human radiation doses on the basis of biodistribution data obtained from mice by dissection. The ratios of estimated effective doses from the human-derived data to those from the mouse-derived data ranged from 0.86 to 1.88. The critical organs that received the highest absorbed doses in the human- and mouse-derived studies differed for two of the six radiotracers. The differences between the human- and mouse-derived dosimetry involved not only the species differences, including faster systemic circulation of mice and differences in the metabolism, but also measurement methodologies. Although the mouse-derived effective doses were roughly comparable to the human-derived doses in most cases, considerable differences were found for critical organ dose estimates and pharmacokinetics in certain cases. Whole-body imaging for investigation of radiation dosimetry is desirable for the initial clinical evaluation of new PET probes prior to their application in subsequent clinical investigations.

  20. Attribute And-Or Grammar for Joint Parsing of Human Pose, Parts and Attributes.

    PubMed

    Park, Seyoung; Nie, Xiaohan; Zhu, Song-Chun

    2017-07-25

    This paper presents an attribute and-or grammar (A-AOG) model for jointly inferring human body pose and human attributes in a parse graph with attributes augmented to nodes in the hierarchical representation. In contrast to other popular methods in the current literature that train separate classifiers for poses and individual attributes, our method explicitly represents the decomposition and articulation of body parts, and account for the correlations between poses and attributes. The A-AOG model is an amalgamation of three traditional grammar formulations: (i)Phrase structure grammar representing the hierarchical decomposition of the human body from whole to parts; (ii)Dependency grammar modeling the geometric articulation by a kinematic graph of the body pose; and (iii)Attribute grammar accounting for the compatibility relations between different parts in the hierarchy so that their appearances follow a consistent style. The parse graph outputs human detection, pose estimation, and attribute prediction simultaneously, which are intuitive and interpretable. We conduct experiments on two tasks on two datasets, and experimental results demonstrate the advantage of joint modeling in comparison with computing poses and attributes independently. Furthermore, our model obtains better performance over existing methods for both pose estimation and attribute prediction tasks.

  1. Investigation of human body potential measured by a non-contact measuring system

    PubMed Central

    ICHIKAWA, Norimitsu

    2016-01-01

    A human body is occasionally electrified in a room. This charged object will be a source of electrostatic accidents, including the malfunction of electronic equipment. Hence, prevention of these accidents is required. Accidents occasionally occur, even though antistatic clothes and shoes are used. One of the causes for these accidents is that there is a lack of the preventive measures. This situation occurs when using, for example, unconductive wax. In this study, human body potential (voltage) is measured using a non-contact measuring system. An investigation of the human body’s voltage when using this system is conducted. The result demonstrates that the voltage of a human body wearing antistatic clothes and shoes or light clothes and slippers exceeds a malfunctioning voltage of a microelectronics device when the body walks on floors. Thus, accidents may occur even if a human body wearing the antistatic clothes walks on flooring. These results will be useful in estimating determination whether electrostatic accidents occur or not. PMID:27319403

  2. Entropy flow and entropy production in the human body in basal conditions.

    PubMed

    Aoki, I

    1989-11-08

    Entropy inflow and outflow for the naked human body in basal conditions in the respiration calorimeter due to infrared radiation, convection, evaporation of water and mass-flow are calculated by use of the energetic data obtained by Hardy & Du Bois. Also, the change of entropy content in the body is estimated. The entropy production in the human body is obtained as the change of entropy content minus the net entropy flow into the body. The entropy production thus calculated becomes positive. The magnitude of entropy production per effective radiating surface area does not show any significant variation with subjects. The entropy production is nearly constant at the calorimeter temperatures of 26-32 degrees C; the average in this temperature range is 0.172 J m-2 sec-1 K-1. The forced air currents around the human body and also clothing have almost no effect in changing the entropy production. Thus, the entropy production of the naked human body in basal conditions does not depend on its environmental factors.

  3. Effect of Body Composition Methodology on Heritability Estimation of Body Fatness

    PubMed Central

    Elder, Sonya J.; Roberts, Susan B.; McCrory, Megan A.; Das, Sai Krupa; Fuss, Paul J.; Pittas, Anastassios G.; Greenberg, Andrew S.; Heymsfield, Steven B.; Dawson-Hughes, Bess; Bouchard, Thomas J.; Saltzman, Edward; Neale, Michael C.

    2014-01-01

    Heritability estimates of human body fatness vary widely and the contribution of body composition methodology to this variability is unknown. The effect of body composition methodology on estimations of genetic and environmental contributions to body fatness variation was examined in 78 adult male and female monozygotic twin pairs reared apart or together. Body composition was assessed by six methods – body mass index (BMI), dual energy x-ray absorptiometry (DXA), underwater weighing (UWW), total body water (TBW), bioelectric impedance (BIA), and skinfold thickness. Body fatness was expressed as percent body fat, fat mass, and fat mass/height2 to assess the effect of body fatness expression on heritability estimates. Model-fitting multivariate analyses were used to assess the genetic and environmental components of variance. Mean BMI was 24.5 kg/m2 (range of 17.8–43.4 kg/m2). There was a significant effect of body composition methodology (p<0.001) on heritability estimates, with UWW giving the highest estimate (69%) and BIA giving the lowest estimate (47%) for fat mass/height2. Expression of body fatness as percent body fat resulted in significantly higher heritability estimates (on average 10.3% higher) compared to expression as fat mass/height2 (p=0.015). DXA and TBW methods expressing body fatness as fat mass/height2 gave the least biased heritability assessments, based on the small contribution of specific genetic factors to their genetic variance. A model combining DXA and TBW methods resulted in a relatively low FM/ht2 heritability estimate of 60%, and significant contributions of common and unique environmental factors (22% and 18%, respectively). The body fatness heritability estimate of 60% indicates a smaller contribution of genetic variance to total variance than many previous studies using less powerful research designs have indicated. The results also highlight the importance of environmental factors and possibly genotype by environmental interactions in the etiology of weight gain and the obesity epidemic. PMID:25067962

  4. Body Parts Dependent Joint Regressors for Human Pose Estimation in Still Images.

    PubMed

    Dantone, Matthias; Gall, Juergen; Leistner, Christian; Van Gool, Luc

    2014-11-01

    In this work, we address the problem of estimating 2d human pose from still images. Articulated body pose estimation is challenging due to the large variation in body poses and appearances of the different body parts. Recent methods that rely on the pictorial structure framework have shown to be very successful in solving this task. They model the body part appearances using discriminatively trained, independent part templates and the spatial relations of the body parts using a tree model. Within such a framework, we address the problem of obtaining better part templates which are able to handle a very high variation in appearance. To this end, we introduce parts dependent body joint regressors which are random forests that operate over two layers. While the first layer acts as an independent body part classifier, the second layer takes the estimated class distributions of the first one into account and is thereby able to predict joint locations by modeling the interdependence and co-occurrence of the parts. This helps to overcome typical ambiguities of tree structures, such as self-similarities of legs and arms. In addition, we introduce a novel data set termed FashionPose that contains over 7,000 images with a challenging variation of body part appearances due to a large variation of dressing styles. In the experiments, we demonstrate that the proposed parts dependent joint regressors outperform independent classifiers or regressors. The method also performs better or similar to the state-of-the-art in terms of accuracy, while running with a couple of frames per second.

  5. Realtime Reconstruction of an Animating Human Body from a Single Depth Camera.

    PubMed

    Chen, Yin; Cheng, Zhi-Quan; Lai, Chao; Martin, Ralph R; Dang, Gang

    2016-08-01

    We present a method for realtime reconstruction of an animating human body,which produces a sequence of deforming meshes representing a given performance captured by a single commodity depth camera. We achieve realtime single-view mesh completion by enhancing the parameterized SCAPE model.Our method, which we call Realtime SCAPE, performs full-body reconstruction without the use of markers.In Realtime SCAPE, estimations of body shape parameters and pose parameters, needed for reconstruction, are decoupled. Intrinsic body shape is first precomputed for a given subject, by determining shape parameters with the aid of a body shape database. Subsequently, per-frame pose parameter estimation is performed by means of linear blending skinning (LBS); the problem is decomposed into separately finding skinning weights and transformations. The skinning weights are also determined offline from the body shape database,reducing online reconstruction to simply finding the transformations in LBS. Doing so is formulated as a linear variational problem;carefully designed constraints are used to impose temporal coherence and alleviate artifacts. Experiments demonstrate that our method can produce full-body mesh sequences with high fidelity.

  6. Human-Derived Disturbance Estimation and Compensation (DEC) Method Lends Itself to a Modular Sensorimotor Control in a Humanoid Robot.

    PubMed

    Lippi, Vittorio; Mergner, Thomas

    2017-01-01

    The high complexity of the human posture and movement control system represents challenges for diagnosis, therapy, and rehabilitation of neurological patients. We envisage that engineering-inspired, model-based approaches will help to deal with the high complexity of the human posture control system. Since the methods of system identification and parameter estimation are limited to systems with only a few DoF, our laboratory proposes a heuristic approach that step-by-step increases complexity when creating a hypothetical human-derived control systems in humanoid robots. This system is then compared with the human control in the same test bed, a posture control laboratory. The human-derived control builds upon the identified disturbance estimation and compensation (DEC) mechanism, whose main principle is to support execution of commanded poses or movements by compensating for external or self-produced disturbances such as gravity effects. In previous robotic implementation, up to 3 interconnected DEC control modules were used in modular control architectures separately for the sagittal plane or the frontal body plane and successfully passed balancing and movement tests. In this study we hypothesized that conflict-free movement coordination between the robot's sagittal and frontal body planes emerges simply from the physical embodiment, not necessarily requiring a full body control. Experiments were performed in the 14 DoF robot Lucy Posturob (i) demonstrating that the mechanical coupling from the robot's body suffices to coordinate the controls in the two planes when the robot produces movements and balancing responses in the intermediate plane, (ii) providing quantitative characterization of the interaction dynamics between body planes including frequency response functions (FRFs), as they are used in human postural control analysis, and (iii) witnessing postural and control stability when all DoFs are challenged together with the emergence of inter-segmental coordination in squatting movements. These findings represent an important step toward controlling in the robot in future more complex sensorimotor functions such as walking.

  7. Human-Derived Disturbance Estimation and Compensation (DEC) Method Lends Itself to a Modular Sensorimotor Control in a Humanoid Robot

    PubMed Central

    Lippi, Vittorio; Mergner, Thomas

    2017-01-01

    The high complexity of the human posture and movement control system represents challenges for diagnosis, therapy, and rehabilitation of neurological patients. We envisage that engineering-inspired, model-based approaches will help to deal with the high complexity of the human posture control system. Since the methods of system identification and parameter estimation are limited to systems with only a few DoF, our laboratory proposes a heuristic approach that step-by-step increases complexity when creating a hypothetical human-derived control systems in humanoid robots. This system is then compared with the human control in the same test bed, a posture control laboratory. The human-derived control builds upon the identified disturbance estimation and compensation (DEC) mechanism, whose main principle is to support execution of commanded poses or movements by compensating for external or self-produced disturbances such as gravity effects. In previous robotic implementation, up to 3 interconnected DEC control modules were used in modular control architectures separately for the sagittal plane or the frontal body plane and successfully passed balancing and movement tests. In this study we hypothesized that conflict-free movement coordination between the robot's sagittal and frontal body planes emerges simply from the physical embodiment, not necessarily requiring a full body control. Experiments were performed in the 14 DoF robot Lucy Posturob (i) demonstrating that the mechanical coupling from the robot's body suffices to coordinate the controls in the two planes when the robot produces movements and balancing responses in the intermediate plane, (ii) providing quantitative characterization of the interaction dynamics between body planes including frequency response functions (FRFs), as they are used in human postural control analysis, and (iii) witnessing postural and control stability when all DoFs are challenged together with the emergence of inter-segmental coordination in squatting movements. These findings represent an important step toward controlling in the robot in future more complex sensorimotor functions such as walking. PMID:28951719

  8. Validating skinfold thickness as a proxy to estimate total body fat in wild toque macaques (Macaca sinica) using the mass of dissected adipose tissue.

    PubMed

    Dittus, Wolfgang P J; Gunathilake, K A Sunil

    2015-06-01

    Skinfold thickness (SFT) has been used often in non-human primates and humans as a proxy to estimate fatness (% body fat). We intended to validate the relation between SFT (in recently deceased specimens) and the mass of adipose tissue as determined from dissection of fresh carcasses of wild toque macaques (Macaca sinica). In adult male and female toque macaques body composition is normally 2% adipose tissue. Calipers for measuring SFT were suitable for measuring only some subcutaneous deposits of adipose tissue but were not suitable for measuring large fat deposits within the body cavity or minor intermuscular ones. The anatomical distribution of 13 different adipose deposits, in different body regions (subcutaneous, intra-abdominal and intermuscular) and their proportional size differences, were consistent in this species (as in other primates), though varying in total mass among individuals. These consistent allometric relationships were fundamental for estimating fatness of different body regions based on SFT. The best fit statistically significant correlations and regressions with the known masses of dissectible adipose tissue were evident between the SFT means of the seven sites measured, as well as with a single point on the abdomen anterior to the umbilicus. SFT related to total fat mass and intra-abdominal fat mass in curvilinear regressions and to subcutaneous fat mass in a linear relationship. To adjust for differences in body size among individuals, and to circumvent intangible variations in total body mass allocated, for example to the gastro-intestinal contents, dissected fat mass was estimated per unit body size (length of crown-rump)(3). SFT had greater coefficients of correlation and regressions with this Fat Mass Index (g/dm(3)) than with Percent Body Fat. © 2015 Wiley Periodicals, Inc.

  9. Exploring point-cloud features from partial body views for gender classification

    NASA Astrophysics Data System (ADS)

    Fouts, Aaron; McCoppin, Ryan; Rizki, Mateen; Tamburino, Louis; Mendoza-Schrock, Olga

    2012-06-01

    In this paper we extend a previous exploration of histogram features extracted from 3D point cloud images of human subjects for gender discrimination. Feature extraction used a collection of concentric cylinders to define volumes for counting 3D points. The histogram features are characterized by a rotational axis and a selected set of volumes derived from the concentric cylinders. The point cloud images are drawn from the CAESAR anthropometric database provided by the Air Force Research Laboratory (AFRL) Human Effectiveness Directorate and SAE International. This database contains approximately 4400 high resolution LIDAR whole body scans of carefully posed human subjects. Success from our previous investigation was based on extracting features from full body coverage which required integration of multiple camera images. With the full body coverage, the central vertical body axis and orientation are readily obtainable; however, this is not the case with a one camera view providing less than one half body coverage. Assuming that the subjects are upright, we need to determine or estimate the position of the vertical axis and the orientation of the body about this axis relative to the camera. In past experiments the vertical axis was located through the center of mass of torso points projected on the ground plane and the body orientation derived using principle component analysis. In a natural extension of our previous work to partial body views, the absence of rotational invariance about the cylindrical axis greatly increases the difficulty for gender classification. Even the problem of estimating the axis is no longer simple. We describe some simple feasibility experiments that use partial image histograms. Here, the cylindrical axis is assumed to be known. We also discuss experiments with full body images that explore the sensitivity of classification accuracy relative to displacements of the cylindrical axis. Our initial results provide the basis for further investigation of more complex partial body viewing problems and new methods for estimating the two position coordinates for the axis location and the unknown body orientation angle.

  10. Human body motion tracking based on quantum-inspired immune cloning algorithm

    NASA Astrophysics Data System (ADS)

    Han, Hong; Yue, Lichuan; Jiao, Licheng; Wu, Xing

    2009-10-01

    In a static monocular camera system, to gain a perfect 3D human body posture is a great challenge for Computer Vision technology now. This paper presented human postures recognition from video sequences using the Quantum-Inspired Immune Cloning Algorithm (QICA). The algorithm included three parts. Firstly, prior knowledge of human beings was used, the key joint points of human could be detected automatically from the human contours and skeletons which could be thinning from the contours; And due to the complexity of human movement, a forecasting mechanism of occlusion joint points was addressed to get optimum 2D key joint points of human body; And then pose estimation recovered by optimizing between the 2D projection of 3D human key joint points and 2D detection key joint points using QICA, which recovered the movement of human body perfectly, because this algorithm could acquire not only the global optimal solution, but the local optimal solution.

  11. Estimation of Human Body Volume (BV) from Anthropometric Measurements Based on Three-Dimensional (3D) Scan Technique.

    PubMed

    Liu, Xingguo; Niu, Jianwei; Ran, Linghua; Liu, Taijie

    2017-08-01

    This study aimed to develop estimation formulae for the total human body volume (BV) of adult males using anthropometric measurements based on a three-dimensional (3D) scanning technique. Noninvasive and reliable methods to predict the total BV from anthropometric measurements based on a 3D scan technique were addressed in detail. A regression analysis of BV based on four key measurements was conducted for approximately 160 adult male subjects. Eight total models of human BV show that the predicted results fitted by the regression models were highly correlated with the actual BV (p < 0.001). Two metrics, the mean value of the absolute difference between the actual and predicted BV (V error ) and the mean value of the ratio between V error and actual BV (RV error ), were calculated. The linear model based on human weight was recommended as the most optimal due to its simplicity and high efficiency. The proposed estimation formulae are valuable for estimating total body volume in circumstances in which traditional underwater weighing or air displacement plethysmography is not applicable or accessible. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

  12. Case report: Time of death estimation of a buried body by modeling a decomposition matrix for a pig carcass.

    PubMed

    Niederegger, Senta; Schermer, Julia; Höfig, Juliane; Mall, Gita

    2015-01-01

    Estimating time of death of buried human bodies is a very difficult task. Casper's rule from 1860 is still widely used which illustrates the lack of suitable methods. In this case study excavations in an arbor revealed the crouching body of a human being, dressed only in boxer shorts and socks. Witnesses were not able to generate a concise answer as to when the person in question was last seen alive; the pieces of information opened a window of 2-6 weeks for the possible time of death. To determine the post mortem interval (PMI) an experiment using a pig carcass was conducted to set up a decomposition matrix. Fitting the autopsy findings of the victim into the decomposition matrix yielded a time of death estimation of 2-3 weeks. This time frame was later confirmed by a new witness. The authors feel confident that a widespread conduction of decomposition matrices using pig carcasses can lead to a great increase of experience and knowledge in PMI estimation of buried bodies and will eventually lead to applicable new methods. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Modular neuron-based body estimation: maintaining consistency over different limbs, modalities, and frames of reference

    PubMed Central

    Ehrenfeld, Stephan; Herbort, Oliver; Butz, Martin V.

    2013-01-01

    This paper addresses the question of how the brain maintains a probabilistic body state estimate over time from a modeling perspective. The neural Modular Modality Frame (nMMF) model simulates such a body state estimation process by continuously integrating redundant, multimodal body state information sources. The body state estimate itself is distributed over separate, but bidirectionally interacting modules. nMMF compares the incoming sensory and present body state information across the interacting modules and fuses the information sources accordingly. At the same time, nMMF enforces body state estimation consistency across the modules. nMMF is able to detect conflicting sensory information and to consequently decrease the influence of implausible sensor sources on the fly. In contrast to the previously published Modular Modality Frame (MMF) model, nMMF offers a biologically plausible neural implementation based on distributed, probabilistic population codes. Besides its neural plausibility, the neural encoding has the advantage of enabling (a) additional probabilistic information flow across the separate body state estimation modules and (b) the representation of arbitrary probability distributions of a body state. The results show that the neural estimates can detect and decrease the impact of false sensory information, can propagate conflicting information across modules, and can improve overall estimation accuracy due to additional module interactions. Even bodily illusions, such as the rubber hand illusion, can be simulated with nMMF. We conclude with an outlook on the potential of modeling human data and of invoking goal-directed behavioral control. PMID:24191151

  14. A Study to Investigate the Sleeping Comfort of Mattress using Finite Element Method

    NASA Astrophysics Data System (ADS)

    Yoshida, Hiroaki; Kamijo, Masayoshi; Shimizu, Yoshio

    Sleep is an essential physiological activity for human beings and many studies have so far investigated sleeping comfort of mattresses. The appropriate measurement of stress distribution within the human body would provide valuable information to us. For the appropriate measurement to estimate stress distribution within the human body, numerical analysis is considered one of the most desirable techniques, and Finite Element Method (FEM), which is widely accepted as a useful numerical technique, was utilized in this study. Since human body dimensions have individual differences, however, it is presumed that the way of the internal stress distribution also changes due to the differences and that the mattress preference varies among different body forms. Thus, we developed three human FEM models reproducing the body forms of three types of male subjects, and investigated the sleeping comfort of mattress based on the relationship between FEM analysis findings and sensory testing results. In comparison with the results of both FEM analysis and sensory testing in the neck region, we found, the sensory testing results corresponded to the FEM analysis findings, and it was possible to estimate subjects' preferences of mattress and comfort in the neck region using the FEM analysis. In this study, we believe, the FEM analysis managed to quantify the subjects' preferences for mattress and to prove itself that it is the valuable tools to examine the sleeping comfort of mattress.

  15. Motion capture based identification of the human body inertial parameters.

    PubMed

    Venture, Gentiane; Ayusawa, Ko; Nakamura, Yoshihiko

    2008-01-01

    Identification of body inertia, masses and center of mass is an important data to simulate, monitor and understand dynamics of motion, to personalize rehabilitation programs. This paper proposes an original method to identify the inertial parameters of the human body, making use of motion capture data and contact forces measurements. It allows in-vivo painless estimation and monitoring of the inertial parameters. The method is described and then obtained experimental results are presented and discussed.

  16. Comparison of organ dose and dose equivalent using ray tracing of male and female Voxel phantoms to space flight phantom torso data

    NASA Astrophysics Data System (ADS)

    Kim, Myung-Hee; Qualls, Garry; Slaba, Tony; Cucinotta, Francis A.

    Phantom torso experiments have been flown on the space shuttle and International Space Station (ISS) providing validation data for radiation transport models of organ dose and dose equivalents. We describe results for space radiation organ doses using a new human geometry model based on detailed Voxel phantoms models denoted for males and females as MAX (Male Adult voXel) and Fax (Female Adult voXel), respectively. These models represent the human body with much higher fidelity than the CAMERA model currently used at NASA. The MAX and FAX models were implemented for the evaluation of directional body shielding mass for over 1500 target points of major organs. Radiation exposure to solar particle events (SPE), trapped protons, and galactic cosmic rays (GCR) were assessed at each specific site in the human body by coupling space radiation transport models with the detailed body shielding mass of MAX/FAX phantom. The development of multiple-point body-shielding distributions at each organ site made it possible to estimate the mean and variance of space dose equivalents at the specific organ. For the estimate of doses to the blood forming organs (BFOs), active marrow distributions in adult were accounted at bone marrow sites over the human body. We compared the current model results to space shuttle and ISS phantom torso experiments and to calculations using the CAMERA model.

  17. Comparison of Organ Dose and Dose Equivalent Using Ray Tracing of Male and Female Voxel Phantoms to Space Flight Phantom Torso Data

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Qualls, Garry D.; Cucinotta, Francis A.

    2008-01-01

    Phantom torso experiments have been flown on the space shuttle and International Space Station (ISS) providing validation data for radiation transport models of organ dose and dose equivalents. We describe results for space radiation organ doses using a new human geometry model based on detailed Voxel phantoms models denoted for males and females as MAX (Male Adult voXel) and Fax (Female Adult voXel), respectively. These models represent the human body with much higher fidelity than the CAMERA model currently used at NASA. The MAX and FAX models were implemented for the evaluation of directional body shielding mass for over 1500 target points of major organs. Radiation exposure to solar particle events (SPE), trapped protons, and galactic cosmic rays (GCR) were assessed at each specific site in the human body by coupling space radiation transport models with the detailed body shielding mass of MAX/FAX phantom. The development of multiple-point body-shielding distributions at each organ site made it possible to estimate the mean and variance of space dose equivalents at the specific organ. For the estimate of doses to the blood forming organs (BFOs), active marrow distributions in adult were accounted at bone marrow sites over the human body. We compared the current model results to space shuttle and ISS phantom torso experiments and to calculations using the CAMERA model.

  18. [An instrument for estimating human body composition using impedance measurement].

    PubMed

    Yin, J; Peng, C

    1997-03-01

    According to the impedance feature of biological tissue, the instrument was designed at 1, 5, 10, 50, 100kHz to measure human impedance, and then to calculate human FAT, FFM, FAT%, TBW, ECW, ICW and so on. A 8031 singlechip microprocessor contacuting used as a control center in the instrument. The part of electric circuit contacuting human body in the instrument was unreally earthing. The instrument was safty, effective, repeatable, and easily manpulative. Prelimintary clinical experiment showed the results measured with the instrument could effectively reflect practical, status of human composition.

  19. Whole-body biodistribution and estimation of radiation-absorbed doses of the dopamine D1 receptor radioligand 11C-NNC 112 in humans.

    PubMed

    Cropley, Vanessa L; Fujita, Masahiro; Musachio, John L; Hong, Jinsoo; Ghose, Subroto; Sangare, Janet; Nathan, Pradeep J; Pike, Victor W; Innis, Robert B

    2006-01-01

    The present study estimated radiation-absorbed doses of the dopamine D(1) receptor radioligand [(11)C]((+)-8-chloro-5-(7-benzofuranyl)-7-hydroxy-3-methyl-2,3,4,5-tetrahydro-1H-3-benzazepine) (NNC 112) in humans, based on dynamic whole-body PET in healthy subjects. Whole-body PET was performed on 7 subjects after injection of 710 +/- 85 MBq of (11)C-NNC 112. Fourteen frames were acquired for a total of 120 min in 7 segments of the body. Regions of interest were drawn on compressed planar images of source organs that could be identified. Radiation dose estimates were calculated from organ residence times using the OLINDA 1.0 program. The organs with the highest radiation-absorbed doses were the gallbladder, liver, lungs, kidneys, and urinary bladder wall. Biexponential fitting of mean bladder activity demonstrated that 15% of activity was excreted via the urine. With a 2.4-h voiding interval, the effective dose was 5.7 microSv/MBq (21.1 mrem/mCi). (11)C-NNC 112 displays a favorable radiation dose profile in humans and would allow multiple PET examinations per year to be performed on the same subject.

  20. Precise determination of anthropometric dimensions by means of image processing methods for estimating human body segment parameter values.

    PubMed

    Baca, A

    1996-04-01

    A method has been developed for the precise determination of anthropometric dimensions from the video images of four different body configurations. High precision is achieved by incorporating techniques for finding the location of object boundaries with sub-pixel accuracy, the implementation of calibration algorithms, and by taking into account the varying distances of the body segments from the recording camera. The system allows automatic segment boundary identification from the video image, if the boundaries are marked on the subject by black ribbons. In connection with the mathematical finite-mass-element segment model of Hatze, body segment parameters (volumes, masses, the three principal moments of inertia, the three local coordinates of the segmental mass centers etc.) can be computed by using the anthropometric data determined videometrically as input data. Compared to other, recently published video-based systems for the estimation of the inertial properties of body segments, the present algorithms reduce errors originating from optical distortions, inaccurate edge-detection procedures, and user-specified upper and lower segment boundaries or threshold levels for the edge-detection. The video-based estimation of human body segment parameters is especially useful in situations where ease of application and rapid availability of comparatively precise parameter values are of importance.

  1. An estimation of the number of cells in the human body.

    PubMed

    Bianconi, Eva; Piovesan, Allison; Facchin, Federica; Beraudi, Alina; Casadei, Raffaella; Frabetti, Flavia; Vitale, Lorenza; Pelleri, Maria Chiara; Tassani, Simone; Piva, Francesco; Perez-Amodio, Soledad; Strippoli, Pierluigi; Canaider, Silvia

    2013-01-01

    All living organisms are made of individual and identifiable cells, whose number, together with their size and type, ultimately defines the structure and functions of an organism. While the total cell number of lower organisms is often known, it has not yet been defined in higher organisms. In particular, the reported total cell number of a human being ranges between 10(12) and 10(16) and it is widely mentioned without a proper reference. To study and discuss the theoretical issue of the total number of cells that compose the standard human adult organism. A systematic calculation of the total cell number of the whole human body and of the single organs was carried out using bibliographical and/or mathematical approaches. A current estimation of human total cell number calculated for a variety of organs and cell types is presented. These partial data correspond to a total number of 3.72 × 10(13). Knowing the total cell number of the human body as well as of individual organs is important from a cultural, biological, medical and comparative modelling point of view. The presented cell count could be a starting point for a common effort to complete the total calculation.

  2. Real-time stylistic prediction for whole-body human motions.

    PubMed

    Matsubara, Takamitsu; Hyon, Sang-Ho; Morimoto, Jun

    2012-01-01

    The ability to predict human motion is crucial in several contexts such as human tracking by computer vision and the synthesis of human-like computer graphics. Previous work has focused on off-line processes with well-segmented data; however, many applications such as robotics require real-time control with efficient computation. In this paper, we propose a novel approach called real-time stylistic prediction for whole-body human motions to satisfy these requirements. This approach uses a novel generative model to represent a whole-body human motion including rhythmic motion (e.g., walking) and discrete motion (e.g., jumping). The generative model is composed of a low-dimensional state (phase) dynamics and a two-factor observation model, allowing it to capture the diversity of motion styles in humans. A real-time adaptation algorithm was derived to estimate both state variables and style parameter of the model from non-stationary unlabeled sequential observations. Moreover, with a simple modification, the algorithm allows real-time adaptation even from incomplete (partial) observations. Based on the estimated state and style, a future motion sequence can be accurately predicted. In our implementation, it takes less than 15 ms for both adaptation and prediction at each observation. Our real-time stylistic prediction was evaluated for human walking, running, and jumping behaviors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. The modular modality frame model: continuous body state estimation and plausibility-weighted information fusion.

    PubMed

    Ehrenfeld, Stephan; Butz, Martin V

    2013-02-01

    Humans show admirable capabilities in movement planning and execution. They can perform complex tasks in various contexts, using the available sensory information very effectively. Body models and continuous body state estimations appear necessary to realize such capabilities. We introduce the Modular Modality Frame (MMF) model, which maintains a highly distributed, modularized body model continuously updating, modularized probabilistic body state estimations over time. Modularization is realized with respect to modality frames, that is, sensory modalities in particular frames of reference and with respect to particular body parts. We evaluate MMF performance on a simulated, nine degree of freedom arm in 3D space. The results show that MMF is able to maintain accurate body state estimations despite high sensor and motor noise. Moreover, by comparing the sensory information available in different modality frames, MMF can identify faulty sensory measurements on the fly. In the near future, applications to lightweight robot control should be pursued. Moreover, MMF may be enhanced with neural encodings by introducing neural population codes and learning techniques. Finally, more dexterous goal-directed behavior should be realized by exploiting the available redundant state representations.

  4. Human motion analysis with detection of subpart deformations

    NASA Astrophysics Data System (ADS)

    Wang, Juhui; Lorette, Guy; Bouthemy, Patrick

    1992-06-01

    One essential constraint used in 3-D motion estimation from optical projections is the rigidity assumption. Because of muscle deformations in human motion, this rigidity requirement is often violated for some regions on the human body. Global methods usually fail to bring stable solutions. This paper presents a model-based approach to combating the effect of muscle deformations in human motion analysis. The approach developed is based on two main stages. In the first stage, the human body is partitioned into different areas, where each area is consistent with a general motion model (not necessarily corresponding to a physical existing motion pattern). In the second stage, the regions are eliminated under the hypothesis that they are not induced by a specific human motion pattern. Each hypothesis is generated by making use of specific knowledge about human motion. A global method is used to estimate the 3-D motion parameters in basis of valid segments. Experiments based on a cycling motion sequence are presented.

  5. COMPARISON OF ORGAN DOSES IN HUMAN PHANTOMS: VARIATIONS DUE TO BODY SIZE AND POSTURE.

    PubMed

    Feng, Xu; Xiang-Hong, Jia; Qian, Liu; Xue-Jun, Yu; Zhan-Chun, Pan; Chun-Xin, Yang

    2017-04-20

    Organ dose calculations performed using human phantoms can provide estimates of astronauts' health risks due to cosmic radiation. However, the characteristics of such phantoms strongly affect the estimation precision. To investigate organ dose variations with body size and posture in human phantoms, a non-uniform rational B-spline boundary surfaces model was constructed based on cryosection images. This model was used to establish four phantoms with different body size and posture parameters, whose organs parameters were changed simultaneously and which were voxelised with 4 × 4 × 4 mm3 resolution. Then, using Monte Carlo transport code, the organ doses caused by ≤500 MeV isotropic incident protons were calculated. The dose variations due to body size differences within a certain range were negligible, and the doses received in crouching and standing-up postures were similar. Therefore, a standard Chinese phantom could be established, and posture changes cannot effectively protect astronauts during solar particle events. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. An optimal state estimation model of sensory integration in human postural balance

    NASA Astrophysics Data System (ADS)

    Kuo, Arthur D.

    2005-09-01

    We propose a model for human postural balance, combining state feedback control with optimal state estimation. State estimation uses an internal model of body and sensor dynamics to process sensor information and determine body orientation. Three sensory modalities are modeled: joint proprioception, vestibular organs in the inner ear, and vision. These are mated with a two degree-of-freedom model of body dynamics in the sagittal plane. Linear quadratic optimal control is used to design state feedback and estimation gains. Nine free parameters define the control objective and the signal-to-noise ratios of the sensors. The model predicts statistical properties of human sway in terms of covariance of ankle and hip motion. These predictions are compared with normal human responses to alterations in sensory conditions. With a single parameter set, the model successfully reproduces the general nature of postural motion as a function of sensory environment. Parameter variations reveal that the model is highly robust under normal sensory conditions, but not when two or more sensors are inaccurate. This behavior is similar to that of normal human subjects. We propose that age-related sensory changes may be modeled with decreased signal-to-noise ratios, and compare the model's behavior with degraded sensors against experimental measurements from older adults. We also examine removal of the model's vestibular sense, which leads to instability similar to that observed in bilateral vestibular loss subjects. The model may be useful for predicting which sensors are most critical for balance, and how much they can deteriorate before posture becomes unstable.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spriggs, G D

    In a previous paper, the composite exposure rate conversion factor (ECF) for nuclear fallout was calculated using a simple theoretical photon-transport model. The theoretical model was used to fill in the gaps in the FGR-12 table generated by ORNL. The FGR-12 table contains the individual conversion factors for approximate 1000 radionuclides. However, in order to calculate the exposure rate during the first 30 minutes following a nuclear detonation, the conversion factors for approximately 2000 radionuclides are needed. From a human-effects standpoint, it is also necessary to have the dose rate conversion factors (DCFs) for all 2000 radionuclides. The DCFs aremore » used to predict the whole-body dose rates that would occur if a human were standing in a radiation field of known exposure rate. As calculated by ORNL, the whole-body dose rate (rem/hr) is approximately 70% of the exposure rate (R/hr) at one meter above the surface. Hence, the individual DCFs could be estimated by multiplying the individual ECFs by 0.7. Although this is a handy rule-of-thumb, a more consistent (and perhaps, more accurate) method of estimating the individual DCFs for the missing radionuclides in the FGR-12 table is to use the linear relationship between DCF and total gamma energy released per decay. This relationship is shown in Figure 1. The DCFs for individual organs in the body can also be estimated from the estimated whole-body DCF. Using the DCFs given FGR-12, the ratio of the organ-specific DCFs to the whole-body DCF were plotted as a function of the whole-body DCF. From these plots, the asymptotic ratios were obtained (see Table 1). Using these asymptotic ratios, the organ-specific DCFs can be estimated using the estimated whole-body DCF for each of the missing radionuclides in the FGR-12 table. Although this procedure for estimating the organ-specific DCFs may over-estimate the value for some low gamma-energy emitters, having a finite value for the organ-specific DCFs in the table is probably better than having no value at all. A summary of the complete ECF and DCF values are given in Table 2.« less

  8. Experimental Study of Radiation Efficiency from an Ingested Source inside a Human Body Model*.

    PubMed

    Chan, Yawen; -H Meng, Max; Wu, K-L; Wang, Xiaona

    2005-01-01

    The attenuation of human body trunk at frequency range of 100MHz to 6GHz from an internal source was estimated using a simplified experimental model. Antennas were placed in the model which was filled with distilled water, 0.9% NaCl saline solution, and porcine body tissue alternately to determine the attenuation of the system. Saline has greater attenuation than water due to its higher conductivity, while porcine body tissue has attenuation bounded by saline solution and water. Estimated attenuation at the four ISM bands, 434MHz, 915MHz, 2.45GHz and 5.8GHz were given and all of these bands satisfied the safety and sensitivity requirements of a biomedical telemetry system. 915MHz and 2.45GHz are good choices for the wireless link because of their relatively larger electrical size of RF components such as antenna. In addition, with the growth in wireless LAN and Bluetooth technology, miniaturized antennas, camera modules, and other RF devices have been developed which can be employed in biomedical ingested or implanted devices. This paper gives a reference of attenuation values of a human body trunk of average size. It should be noted that the attenuation values can be different for different body size and different body composition, and therefore the values in this paper serves as a reference only.

  9. Real-time 3D human pose recognition from reconstructed volume via voxel classifiers

    NASA Astrophysics Data System (ADS)

    Yoo, ByungIn; Choi, Changkyu; Han, Jae-Joon; Lee, Changkyo; Kim, Wonjun; Suh, Sungjoo; Park, Dusik; Kim, Junmo

    2014-03-01

    This paper presents a human pose recognition method which simultaneously reconstructs a human volume based on ensemble of voxel classifiers from a single depth image in real-time. The human pose recognition is a difficult task since a single depth camera can capture only visible surfaces of a human body. In order to recognize invisible (self-occluded) surfaces of a human body, the proposed algorithm employs voxel classifiers trained with multi-layered synthetic voxels. Specifically, ray-casting onto a volumetric human model generates a synthetic voxel, where voxel consists of a 3D position and ID corresponding to the body part. The synthesized volumetric data which contain both visible and invisible body voxels are utilized to train the voxel classifiers. As a result, the voxel classifiers not only identify the visible voxels but also reconstruct the 3D positions and the IDs of the invisible voxels. The experimental results show improved performance on estimating the human poses due to the capability of inferring the invisible human body voxels. It is expected that the proposed algorithm can be applied to many fields such as telepresence, gaming, virtual fitting, wellness business, and real 3D contents control on real 3D displays.

  10. Population Physiologically-Based Pharmacokinetic Modeling for the Human Lactational Transfer of PCB 153 with Consideration of Worldwide Human Biomonitoring Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Redding, Laurel E.; Sohn, Michael D.; McKone, Thomas E.

    2008-03-01

    We developed a physiologically based pharmacokinetic model of PCB 153 in women, and predict its transfer via lactation to infants. The model is the first human, population-scale lactational model for PCB 153. Data in the literature provided estimates for model development and for performance assessment. Physiological parameters were taken from a cohort in Taiwan and from reference values in the literature. We estimated partition coefficients based on chemical structure and the lipid content in various body tissues. Using exposure data in Japan, we predicted acquired body burden of PCB 153 at an average childbearing age of 25 years and comparemore » predictions to measurements from studies in multiple countries. Forward-model predictions agree well with human biomonitoring measurements, as represented by summary statistics and uncertainty estimates. The model successfully describes the range of possible PCB 153 dispositions in maternal milk, suggesting a promising option for back estimating doses for various populations. One example of reverse dosimetry modeling was attempted using our PBPK model for possible exposure scenarios in Canadian Inuits who had the highest level of PCB 153 in their milk in the world.« less

  11. Age estimation by amino acid racemization in human teeth.

    PubMed

    Ohtani, Susumu; Yamamoto, Toshiharu

    2010-11-01

    When an unidentified body is found, it is essential to establish the personal identity of the body in addition to investigating the cause of death. Identification is one of the most important functions of forensic dentistry. Fingerprint, dental, and DNA analysis can be used to accurately identify a body. However, if no information is available for identification, age estimation can contribute to the resolution of a case. The authors have been using aspartic acid racemization rates in dentin (D-aspartic acid/L-aspartic acid: D/L Asp) as an index for age estimation and have obtained satisfactory results. We report five cases of age estimation using the racemization method. In all five cases, estimated ages were accurate within a range ±3 years. We conclude that the racemization method is a reliable and practical method for estimating age. © 2010 American Academy of Forensic Sciences.

  12. Validity of Three-Dimensional Photonic Scanning Technique for Estimating Percent Body Fat.

    PubMed

    Shitara, K; Kanehisa, H; Fukunaga, T; Yanai, T; Kawakami, Y

    2013-01-01

    Three-dimensional photonic scanning (3DPS) was recently developed to measure dimensions of a human body surface. The purpose of this study was to explore the validity of body volume measured by 3DPS for estimating the percent body fat (%fat). Design, setting, participants, and measurement: The body volumes were determined by 3DPS in 52 women. The body volume was corrected for residual lung volume. The %fat was estimated from body density and compared with the corresponding reference value determined by the dual-energy x-ray absorptiometry (DXA). No significant difference was found for the mean values of %fat obtained by 3DPS (22.2 ± 7.6%) and DXA (23.5 ± 4.9%). The root mean square error of %fat between 3DPS and reference technique was 6.0%. For each body segment, there was a significant positive correlation between 3DPS- and DXA-values, although the corresponding value for the head was slightly larger in 3DPS than in DXA. Residual lung volume was negatively correlated with the estimated error in %fat. The body volume determined with 3DPS is potentially useful for estimating %fat. A possible strategy for enhancing the measurement accuracy of %fat might be to refine the protocol for preparing the subject's hair prior to scanning and to improve the accuracy in the measurement of residual lung volume.

  13. Extension of perceived arm length following tool-use: clues to plasticity of body metrics.

    PubMed

    Sposito, Ambra; Bolognini, Nadia; Vallar, Giuseppe; Maravita, Angelo

    2012-07-01

    Humans hold a very accurate representation of the metrics of their body parts. Recent evidence shows that the spatial estimation of body parts length, as assessed through a bisection task, is even more accurate than that of non-corporeal extrapersonal objects (Sposito, Bolognini, Vallar, Posteraro, & Maravita (2009)). In the present paper we show that human participants estimate the mid-point of their forearm, which was kept in a radial posture, to be more distal following a 15-min training with a 60 cm-long tool as compared to pre tool-use. This outcome is compatible with an increased representation of the participants' forearm length. Control experiments show that this result was not due to a mere distal proprioceptive shift induced by tool-use, and was not replicated following the use of a 20 cm-long, functionally irrelevant tool. These results strongly support the view that, although the inner knowledge of one's own body metrics appears to be one of the more stable features of body representation, body-space interactions requiring the use of tools that extend the natural range of action, entail measurable dynamic changes in the representation of body metrics. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Noninvasive oxygen partial pressure measurement of human body fluids in vivo using magnetic resonance imaging.

    PubMed

    Zaharchuk, Greg; Busse, Reed F; Rosenthal, Guy; Manley, Geoffery T; Glenn, Orit A; Dillon, William P

    2006-08-01

    The oxygen partial pressure (pO2) of human body fluids reflects the oxygenation status of surrounding tissues. All existing fluid pO2 measurements are invasive, requiring either microelectrode/optode placement or fluid removal. The purpose of this study is to develop a noninvasive magnetic resonance imaging method to measure the pO2 of human body fluids. We developed an imaging paradigm that exploits the paramagnetism of molecular oxygen to create quantitative images of fluid oxygenation. A single-shot fast spin echo pulse sequence was modified to minimize artifacts from motion, fluid flow, and partial volume. Longitudinal relaxation rate (R1 = 1/T1) was measured with a time-efficient nonequilibrium saturation recovery method and correlated with pO2 measured in phantoms. pO2 images of human and fetal cerebrospinal fluid, bladder urine, and vitreous humor are presented and quantitative oxygenation levels are compared with prior literature estimates, where available. Significant pO2 increases are shown in cerebrospinal fluid and vitreous following 100% oxygen inhalation. Potential errors due to temperature, fluid flow, and partial volume are discussed. Noninvasive measurements of human body fluid pO2 in vivo are presented, which yield reasonable values based on prior literature estimates. This rapid imaging-based measurement of fluid oxygenation may provide insight into normal physiology as well as changes due to disease or during treatment.

  15. Iteration of ultrasound aberration correction methods

    NASA Astrophysics Data System (ADS)

    Maasoey, Svein-Erik; Angelsen, Bjoern; Varslot, Trond

    2004-05-01

    Aberration in ultrasound medical imaging is usually modeled by time-delay and amplitude variations concentrated on the transmitting/receiving array. This filter process is here denoted a TDA filter. The TDA filter is an approximation to the physical aberration process, which occurs over an extended part of the human body wall. Estimation of the TDA filter, and performing correction on transmit and receive, has proven difficult. It has yet to be shown that this method works adequately for severe aberration. Estimation of the TDA filter can be iterated by retransmitting a corrected signal and re-estimate until a convergence criterion is fulfilled (adaptive imaging). Two methods for estimating time-delay and amplitude variations in receive signals from random scatterers have been developed. One method correlates each element signal with a reference signal. The other method use eigenvalue decomposition of the receive cross-spectrum matrix, based upon a receive energy-maximizing criterion. Simulations of iterating aberration correction with a TDA filter have been investigated to study its convergence properties. A weak and strong human-body wall model generated aberration. Both emulated the human abdominal wall. Results after iteration improve aberration correction substantially, and both estimation methods converge, even for the case of strong aberration.

  16. Total Body Capacitance for Estimating Human Basal Metabolic Rate in an Egyptian Population

    PubMed Central

    M. Abdel-Mageed, Samir; I. Mohamed, Ehab

    2016-01-01

    Determining basal metabolic rate (BMR) is important for estimating total energy needs in the human being yet, concerns have been raised regarding the suitability of sex-specific equations based on age and weight for its calculation on an individual or population basis. It has been shown that body cell mass (BCM) is the body compartment responsible for BMR. The objectives of this study were to investigate the relationship between total body capacitance (TBC), which is considered as an expression for BCM, and BMR and to develop a formula for calculating BMR in comparison with widely used equations. Fifty healthy nonsmoking male volunteers [mean age (± SD): 24.93 ± 4.15 year and body mass index (BMI): 25.63 ± 3.59 kg/m2] and an equal number of healthy nonsmoking females matched for age and BMI were recruited for the study. TBC and BMR were measured for all participants using octopolar bioelectric impedance analysis and indirect calorimetry techniques, respectively. A significant regressing equation based on the covariates: sex, weight, and TBC for estimating BMR was derived (R=0.96, SEE=48.59 kcal, and P<0.0001), which will be useful for nutritional and health status assessment for both individuals and populations. PMID:27127453

  17. Statistical analysis of whole-body absorption depending on anatomical human characteristics at a frequency of 2.1 GHz.

    PubMed

    Habachi, A El; Conil, E; Hadjem, A; Vazquez, E; Wong, M F; Gati, A; Fleury, G; Wiart, J

    2010-04-07

    In this paper, we propose identification of the morphological factors that may impact the whole-body averaged specific absorption rate (WBSAR). This study is conducted for the case of exposure to a front plane wave at a 2100 MHz frequency carrier. This study is based on the development of different regression models for estimating the WBSAR as a function of morphological factors. For this purpose, a database of 12 anatomical human models (phantoms) has been considered. Also, 18 supplementary phantoms obtained using the morphing technique were generated to build the required relation. This paper presents three models based on external morphological factors such as the body surface area, the body mass index or the body mass. These models show good results in estimating the WBSAR (<10%) for families obtained by the morphing technique, but these are still less accurate (30%) when applied to different original phantoms. This study stresses the importance of the internal morphological factors such as muscle and fat proportions in characterization of the WBSAR. The regression models are then improved using internal morphological factors with an estimation error of approximately 10% on the WBSAR. Finally, this study is suitable for establishing the statistical distribution of the WBSAR for a given population characterized by its morphology.

  18. Statistical analysis of whole-body absorption depending on anatomical human characteristics at a frequency of 2.1 GHz

    NASA Astrophysics Data System (ADS)

    El Habachi, A.; Conil, E.; Hadjem, A.; Vazquez, E.; Wong, M. F.; Gati, A.; Fleury, G.; Wiart, J.

    2010-04-01

    In this paper, we propose identification of the morphological factors that may impact the whole-body averaged specific absorption rate (WBSAR). This study is conducted for the case of exposure to a front plane wave at a 2100 MHz frequency carrier. This study is based on the development of different regression models for estimating the WBSAR as a function of morphological factors. For this purpose, a database of 12 anatomical human models (phantoms) has been considered. Also, 18 supplementary phantoms obtained using the morphing technique were generated to build the required relation. This paper presents three models based on external morphological factors such as the body surface area, the body mass index or the body mass. These models show good results in estimating the WBSAR (<10%) for families obtained by the morphing technique, but these are still less accurate (30%) when applied to different original phantoms. This study stresses the importance of the internal morphological factors such as muscle and fat proportions in characterization of the WBSAR. The regression models are then improved using internal morphological factors with an estimation error of approximately 10% on the WBSAR. Finally, this study is suitable for establishing the statistical distribution of the WBSAR for a given population characterized by its morphology.

  19. Biodistribution and radiation dosimetry of the hypoxia marker 18F-HX4 in monkeys and humans determined by using whole-body PET/CT.

    PubMed

    Doss, Mohan; Zhang, James J; Bélanger, Marie-José; Stubbs, James B; Hostetler, Eric D; Alpaugh, Katherine; Kolb, Hartmuth C; Yu, Jian Q

    2010-12-01

    F-HX4 is a novel positron emission tomography (PET) tracer for imaging hypoxia. The purpose of this study was to determine the biodistribution and estimate the radiation dose of F-HX4 using whole-body PET/computed tomography (CT) scans in monkeys and humans. Successive whole-body PET/CT scans were done after the injection of F-HX4 in four healthy humans (422±142 MBq) and in three rhesus monkeys (189±3 MBq). Biodistribution was determined from PET images and organ doses were estimated using OLINDA/EXM software. The bladder, liver, and kidneys showed the highest percentage of the injected radioactivity for humans and monkeys. For humans, approximately 45% of the activity is eliminated by bladder voiding in 3.6 h, and for monkeys 60% is in the bladder content after 3 h. The critical organ is the urinary bladder wall with the highest absorbed radiation dose of 415±18 (monkeys) and 299±38 μGy/MBq (humans), in the 4.8-h bladder voiding interval model. The average value of effective dose for the adult male was estimated at 42±4.2 μSv/MBq from monkey data and 27±2 μSv/MBq from human data. Bladder, kidneys, and liver have the highest uptake of injected F-HX4 activity for both monkeys and humans. The urinary bladder wall receives the highest dose of F-HX4 and is the critical organ. Thus, patients should be encouraged to maintain adequate hydration and void frequently. The effective dose of F-HX4 is comparable with that of other F-based imaging agents.

  20. Evaluation of multiple frequency bioelectrical impedance and Cole-Cole analysis for the assessment of body water volumes in healthy humans.

    PubMed

    Cornish, B H; Ward, L C; Thomas, B J; Jebb, S A; Elia, M

    1996-03-01

    To assess the application of a Cole-Cole analysis of multiple frequency bioelectrical impedance analysis (MFBIA) measurements to predict total body water (TBW) and extracellular water (ECW) in humans. This technique has previously been shown to produce accurate and reliable estimates in both normal and abnormal animals. The whole body impedance of 60 healthy humans was measured at 496 frequencies (ranging from 4 kHz to 1 MHz) and the impedance at zero frequency, Ro, and at the characteristic frequency, Zc, were determined from the impedance spectrum, (Cole-Cole plot). TBW and ECW were independently determined using deuterium and bromide tracer dilution techniques. At the Dunn Clinical Nutrition Centre and The Department of Biochemistry, University of Queensland. 60 healthy adult volunteers (27 men and 33 women, aged 18-45 years). The results presented suggest that the swept frequency bioimpedance technique estimates total body water, (SEE = 5.2%), and extracellular water, (SEE = 10%), only slightly better in normal, healthy subjects than a method based on single frequency bioimpedance or anthropometric estimates based on weight, height and gender. This study has undertaken the most extensive analysis to date of relationships between TBW (and ECW) and individual impedances obtained at different frequencies ( > 400 frequencies), and has shown marginal advantages of using one frequency over another, even if values predicted from theoretical bioimpedance models are used in the estimations. However in situations where there are disturbances of fluid distribution, values predicted from the Cole-Cole analysis of swept frequency bioimpedance measurements could prove to be more useful.

  1. A portable meter for measuring low frequency currents in the human body.

    PubMed

    Niple, J C; Daigle, J P; Zaffanella, L E; Sullivan, T; Kavet, R

    2004-07-01

    A portable meter has been developed for measuring low frequency currents that flow in the human body. Although the present version of the meter was specifically designed to measure 50/60 Hz "contact currents," the principles involved can be used with other low frequency body currents. Contact currents flow when the human body provides a conductive path between objects in the environment with different electrical potentials. The range of currents the meter detects is approximately 0.4-800 microA. This provides measurements of currents from the threshold of human perception (approximately 500 microA(RMS)) down to single microampere levels. The meter has a unique design, which utilizes the human subject's body impedance as the sensing element. Some of the advantages of this approach are high sensitivity, the ability to measure current flow in the majority of the body, and relative insensitivity to the current path connection points. Current measurement accuracy varies with the accuracy of the body impedance (resistance) measurement and different techniques can be used to obtain a desired level of accuracy. Techniques are available to achieve an estimated +/-20% accuracy. Copyright 2004 Wiley-Liss, Inc.

  2. Stability, precision, and near-24-hour period of the human circadian pacemaker

    NASA Technical Reports Server (NTRS)

    Czeisler, C. A.; Duffy, J. F.; Shanahan, T. L.; Brown, E. N.; Mitchell, J. F.; Rimmer, D. W.; Ronda, J. M.; Silva, E. J.; Allan, J. S.; Emens, J. S.; hide

    1999-01-01

    Regulation of circadian period in humans was thought to differ from that of other species, with the period of the activity rhythm reported to range from 13 to 65 hours (median 25.2 hours) and the period of the body temperature rhythm reported to average 25 hours in adulthood, and to shorten with age. However, those observations were based on studies of humans exposed to light levels sufficient to confound circadian period estimation. Precise estimation of the periods of the endogenous circadian rhythms of melatonin, core body temperature, and cortisol in healthy young and older individuals living in carefully controlled lighting conditions has now revealed that the intrinsic period of the human circadian pacemaker averages 24.18 hours in both age groups, with a tight distribution consistent with other species. These findings have important implications for understanding the pathophysiology of disrupted sleep in older people.

  3. Preliminary Upper Estimate of Peak Currents in Transcranial Magnetic Stimulation at Distant Locations from a TMS Coil

    PubMed Central

    Makarov, Sergey N.; Yanamadala, Janakinadh; Piazza, Matthew W.; Helderman, Alex M.; Thang, Niang S.; Burnham, Edward H.; Pascual-Leone, Alvaro

    2016-01-01

    Goals Transcranial magnetic stimulation (TMS) is increasingly used as a diagnostic and therapeutic tool for numerous neuropsychiatric disorders. The use of TMS might cause whole-body exposure to undesired induced currents in patients and TMS operators. The aim of the present study is to test and justify a simple analytical model known previously, which may be helpful as an upper estimate of eddy current density at a particular distant observation point for any body composition and any coil setup. Methods We compare the analytical solution with comprehensive adaptive mesh refinement-based FEM simulations of a detailed full-body human model, two coil types, five coil positions, about 100,000 observation points, and two distinct pulse rise times, thus providing a representative number of different data sets for comparison, while also using other numerical data. Results Our simulations reveal that, after a certain modification, the analytical model provides an upper estimate for the eddy current density at any location within the body. In particular, it overestimates the peak eddy currents at distant locations from a TMS coil by a factor of 10 on average. Conclusion The simple analytical model tested in the present study may be valuable as a rapid method to safely estimate levels of TMS currents at different locations within a human body. Significance At present, safe limits of general exposure to TMS electric and magnetic fields are an open subject, including fetal exposure for pregnant women. PMID:26685221

  4. Comparison of decomposition rates between autopsied and non-autopsied human remains.

    PubMed

    Bates, Lennon N; Wescott, Daniel J

    2016-04-01

    Penetrating trauma has been cited as a significant factor in the rate of decomposition. Therefore, penetrating trauma may have an effect on estimations of time-since-death in medicolegal investigations and on research examining decomposition rates and processes when autopsied human bodies are used. The goal of this study was to determine if there are differences in the rate of decomposition between autopsied and non-autopsied human remains in the same environment. The purpose is to shed light on how large incisions, such as those from a thorocoabdominal autopsy, effect time-since-death estimations and research on the rate of decomposition that use both autopsied and non-autopsied human remains. In this study, 59 non-autopsied and 24 autopsied bodies were studied. The number of accumulated degree days required to reach each decomposition stage was then compared between autopsied and non-autopsied remains. Additionally, both types of bodies were examined for seasonal differences in decomposition rates. As temperature affects the rate of decomposition, this study also compared the internal body temperatures of autopsied and non-autopsied remains to see if differences between the two may be leading to differential decomposition. For this portion of this study, eight non-autopsied and five autopsied bodies were investigated. Internal temperature was collected once a day for two weeks. The results showed that differences in the decomposition rate between autopsied and non-autopsied remains was not statistically significant, though the average ADD needed to reach each stage of decomposition was slightly lower for autopsied bodies than non-autopsied bodies. There was also no significant difference between autopsied and non-autopsied bodies in the rate of decomposition by season or in internal temperature. Therefore, this study suggests that it is unnecessary to separate autopsied and non-autopsied remains when studying gross stages of human decomposition in Central Texas and that penetrating trauma may not be a significant factor in the overall rate of decomposition. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Hierarchical graphical-based human pose estimation via local multi-resolution convolutional neural network

    NASA Astrophysics Data System (ADS)

    Zhu, Aichun; Wang, Tian; Snoussi, Hichem

    2018-03-01

    This paper addresses the problems of the graphical-based human pose estimation in still images, including the diversity of appearances and confounding background clutter. We present a new architecture for estimating human pose using a Convolutional Neural Network (CNN). Firstly, a Relative Mixture Deformable Model (RMDM) is defined by each pair of connected parts to compute the relative spatial information in the graphical model. Secondly, a Local Multi-Resolution Convolutional Neural Network (LMR-CNN) is proposed to train and learn the multi-scale representation of each body parts by combining different levels of part context. Thirdly, a LMR-CNN based hierarchical model is defined to explore the context information of limb parts. Finally, the experimental results demonstrate the effectiveness of the proposed deep learning approach for human pose estimation.

  6. Predictive dose-based estimation of systemic exposure multiples in mouse and monkey relative to human for antisense oligonucleotides with 2'-o-(2-methoxyethyl) modifications.

    PubMed

    Yu, Rosie Z; Grundy, John S; Henry, Scott P; Kim, Tae-Won; Norris, Daniel A; Burkey, Jennifer; Wang, Yanfeng; Vick, Andrew; Geary, Richard S

    2015-01-20

    Evaluation of species differences and systemic exposure multiples (or ratios) in toxicological animal species versus human is an ongoing exercise during the course of drug development. The systemic exposure ratios are best estimated by directly comparing area under the plasma concentration-time curves (AUCs), and sometimes by comparing the dose administered, with the dose being adjusted either by body surface area (BSA) or body weight (BW). In this study, the association between AUC ratio and the administered dose ratio from animals to human were studied using a retrospective data-driven approach. The dataset included nine antisense oligonucleotides (ASOs) with 2'-O-(2-methoxyethyl) modifications, evaluated in two animal species (mouse and monkey) following single and repeated parenteral administrations. We found that plasma AUCs were similar between ASOs within the same species, and are predictable to human exposure using a single animal species, either mouse or monkey. Between monkey and human, the plasma exposure ratio can be predicted directly based on BW-adjusted dose ratios, whereas between mouse and human, the exposure ratio would be nearly fivefold lower in mouse compared to human based on BW-adjusted dose values. Thus, multiplying a factor of 5 for the mouse BW-adjusted dose would likely provide a reasonable AUC exposure estimate in human at steady-state.

  7. Heat loss and hypothermia in free diving: Estimation of survival time under water

    NASA Astrophysics Data System (ADS)

    Aguilella-Arzo, Marcel; Alcaraz, Antonio; Aguilella, Vicente M.

    2003-04-01

    The heat exchange between a diver and the colder surrounding water is analyzed on the basis of the fundamental equations of thermal transport. To estimate the decrease in the diver's body temperature as a function of time, we discuss the complex interplay of several factors including the body heat production rate, the role of the diver's wet suit, and the way different heat exchange mechanisms (conduction, convection, and radiation) contribute to thermal transport. This knowledge could be useful to prevent physiological disorders that occur when the human body temperature drops below 35 °C.

  8. Computer Aided Multi-Data Fusion Dismount Modeling

    DTIC Science & Technology

    2012-03-22

    The ability of geometric morphometric methods to estimate a known covariance matrix., volume 49. Systematic Biology, 2000. [39] Wang C., Yuen M...the use of human shape descriptors like landmarks, body composition, body segmentation, skeletonisation, body representation using geometrical shapes...Springer. [10] Bookstein, F. L. “ Morphometric Tools for Landmark Data: Geometry and Biology.” Cambridge University Press, 1991. [11] Borengasser, M

  9. Skeletal muscle mass in human athletes: What is the upper limit?

    PubMed

    Abe, Takashi; Buckner, Samuel L; Dankel, Scott J; Jessee, Matthew B; Mattocks, Kevin T; Mouser, J Grant; Loenneke, Jeremy P

    2018-01-22

    To examine the amount of absolute and relative skeletal muscle mass (SM) in large sized athletes to investigate the potential upper limit of whole body muscle mass accumulation in the human body. Ninety-five large-sized male athletes and 48 recreationally active males (control) had muscle thickness measured by ultrasound at nine sites on the anterior and posterior aspects of the body. SM was estimated from an ultrasound-derived prediction equation. Body density was estimated by hydrostatic weighing technique, and then body fat percentage and fat-free mass (FFM) were calculated. We used the SM index and FFM index to adjust for the influence of standing height (ie, divided by height squared). Ten of the athletes had more than 100 kg of FFM, including the largest who had 120.2 kg, while seven of the athletes had more than 50 kg of SM, including the largest who had 59.3 kg. FFM index and SM index were higher in athletes compared to controls and the percentage differences between the two groups were 44% and 56%, respectively. The FFM index increased linearly up to 90 kg of body mass, and then the values leveled off in those of increasing body mass. Similarly, the SM index increased in a parabolic fashion reaching a plateau (approximately 17 kg/m 2 ) beyond 120 kg body mass. SM index may be a valuable indicator for determining skeletal muscle mass in athletes. A SM index of approximately 17 kg/m 2 may serve as the potential upper limit in humans. © 2018 Wiley Periodicals, Inc.

  10. Gender recognition from unconstrained and articulated human body.

    PubMed

    Wu, Qin; Guo, Guodong

    2014-01-01

    Gender recognition has many useful applications, ranging from business intelligence to image search and social activity analysis. Traditional research on gender recognition focuses on face images in a constrained environment. This paper proposes a method for gender recognition in articulated human body images acquired from an unconstrained environment in the real world. A systematic study of some critical issues in body-based gender recognition, such as which body parts are informative, how many body parts are needed to combine together, and what representations are good for articulated body-based gender recognition, is also presented. This paper also pursues data fusion schemes and efficient feature dimensionality reduction based on the partial least squares estimation. Extensive experiments are performed on two unconstrained databases which have not been explored before for gender recognition.

  11. Gender Recognition from Unconstrained and Articulated Human Body

    PubMed Central

    Wu, Qin; Guo, Guodong

    2014-01-01

    Gender recognition has many useful applications, ranging from business intelligence to image search and social activity analysis. Traditional research on gender recognition focuses on face images in a constrained environment. This paper proposes a method for gender recognition in articulated human body images acquired from an unconstrained environment in the real world. A systematic study of some critical issues in body-based gender recognition, such as which body parts are informative, how many body parts are needed to combine together, and what representations are good for articulated body-based gender recognition, is also presented. This paper also pursues data fusion schemes and efficient feature dimensionality reduction based on the partial least squares estimation. Extensive experiments are performed on two unconstrained databases which have not been explored before for gender recognition. PMID:24977203

  12. The effect of age and body composition on body mass estimation of males using the stature/bi-iliac method.

    PubMed

    Junno, Juho-Antti; Niskanen, Markku; Maijanen, Heli; Holt, Brigitte; Sladek, Vladimir; Niinimäki, Sirpa; Berner, Margit

    2018-02-01

    The stature/bi-iliac breadth method provides reasonably precise, skeletal frame size (SFS) based body mass (BM) estimations across adults as a whole. In this study, we examine the potential effects of age changes in anthropometric dimensions on the estimation accuracy of SFS-based body mass estimation. We use anthropometric data from the literature and our own skeletal data from two osteological collections to study effects of age on stature, bi-iliac breadth, body mass, and body composition, as they are major components behind body size and body size estimations. We focus on males, as relevant longitudinal data are based on male study samples. As a general rule, lean body mass (LBM) increases through adolescence and early adulthood until people are aged in their 30s or 40s, and starts to decline in the late 40s or early 50s. Fat mass (FM) tends to increase until the mid-50s and declines thereafter, but in more mobile traditional societies it may decline throughout adult life. Because BM is the sum of LBM and FM, it exhibits a curvilinear age-related pattern in all societies. Skeletal frame size is based on stature and bi-iliac breadth, and both of those dimensions are affected by age. Skeletal frame size based body mass estimation tends to increase throughout adult life in both skeletal and anthropometric samples because an age-related increase in bi-iliac breadth more than compensates for an age-related stature decline commencing in the 30s or 40s. Combined with the above-mentioned curvilinear BM change, this results in curvilinear estimation bias. However, for simulations involving low to moderate percent body fat, the stature/bi-iliac method works well in predicting body mass in younger and middle-aged adults. Such conditions are likely to have applied to most human paleontological and archaeological samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Comparative assessment of endocrine modulators with oestrogenic activity: I. Definition of a hygiene-based margin of safety (HBMOS) for xeno-oestrogens against the background of European developments.

    PubMed

    Bolt, H M; Janning, P; Michna, H; Degen, G H

    2001-01-01

    A novel concept - the hygiene-based margin of safety (HBMOS) - is suggested for the assessment of the impact of potential endocrine modulators. It integrates exposure scenarios and potency data for industrial chemicals and naturally occurring dietary compounds with oestrogenic activity. An HBMOS is defined as a quotient of estimated daily intakes weighted by the relative in vivo potencies of these compounds. The Existing Chemicals Programme of the European Union provides Human and Environmental Risk Assessments of Existing Chemicals which include human exposure scenarios. Such exposure scenarios, along with potency estimates for endocrine activities, may provide a basis for a quantitative comparison of the potential endocrine-modulating effects of industrial chemicals with endocrine modulators as natural constituents of human diet. Natural phyto-oestrogens exhibit oestrogenic activity in vitro and in vivo. Important phyto-oestrogens for humans are isoflavones (daidzein, genistein) and lignans, with the highest quantities found in soybeans and flaxseed, respectively. Daily isoflavone exposures calculated for infants on soy-based formulae were in the ranges of 4.5-8 mg/kg body wt.; estimates for adults range up to 1 mg/kg body wt. The Senate Commission on the Evaluation of Food Safety (SKLM) of the Deutsche Forschungsgemeinschaft has also indicated a wide range of dietary exposures. For matters of risk assessment, the SKLM has based recommendations on dietary exposure scenarios, implying a daily intake of phyto-oestrogens in the order of 1 mg/kg body wt. On the basis of information compiled within the Existing Chemicals Programme of the EU, it appears that a daily human exposure to nonylphenol of 2 microg/kg body wt. may be a worst-case assumption, but which is based on valid scenarios. The intake of octylphenol is much lower, due to a different use pattern and applications, and may be neglected. Data from migration studies led to estimations of the daily human uptake of bisphenol A of maximally 1 microg/kg body wt. On the basis of comparative data from uterotrophic assays in rats, with three consecutive days of oral applications involved, and taking the natural phyto-oestrogen daidzein as reference (= 1), relative uterotrophic activities in DA/Han rats follow the sequence: daidzein = 1; bisphenol A = 1; p-tertoctylphenol = 2; o, p'-DDT = 4; ethinyl oestradiol = 40,000. The derived values from exposure scenarios, as well as these relative potency values and bridging assumptions, led to calculations of HBMOS as a quantitative comparison of potential endocrine-modulating effects of industrial chemicals with those of natural constituents of human diet. HBMOS estimates for nonylphenol ranged between 250 and 500, dependent on bridging assumptions, and around 1000 for bisphenol A. The derivations of HBMOS were in full support of the conclusions reached by the SKLM of the Deutsche Forschungsgemeinschaft. The estimated HBMOS values for the industrial chemicals (nonylphenol, bisphenol A) appear sufficiently high to ensure the absence of a practical risk to human health under the present exposure conditions.

  14. Three-dimensional surface imaging system for assessing human obesity

    NASA Astrophysics Data System (ADS)

    Xu, Bugao; Yu, Wurong; Yao, Ming; Pepper, M. Reese; Freeland-Graves, Jeanne H.

    2009-10-01

    The increasing prevalence of obesity suggests a need to develop a convenient, reliable, and economical tool for assessment of this condition. Three-dimensional (3-D) body surface imaging has emerged as an exciting technology for the estimation of body composition. We present a new 3-D body imaging system, which is designed for enhanced portability, affordability, and functionality. In this system, stereo vision technology is used to satisfy the requirement for a simple hardware setup and fast image acquisition. The portability of the system is created via a two-stand configuration, and the accuracy of body volume measurements is improved by customizing stereo matching and surface reconstruction algorithms that target specific problems in 3-D body imaging. Body measurement functions dedicated to body composition assessment also are developed. The overall performance of the system is evaluated in human subjects by comparison to other conventional anthropometric methods, as well as air displacement plethysmography, for body fat assessment.

  15. A 3D surface imaging system for assessing human obesity

    NASA Astrophysics Data System (ADS)

    Xu, B.; Yu, W.; Yao, M.; Yao, X.; Li, Q.; Pepper, M. R.; Freeland-Graves, J. H.

    2009-08-01

    The increasing prevalence of obesity suggests a need to develop a convenient, reliable and economical tool for assessment of this condition. Three-dimensional (3D) body surface imaging has emerged as an exciting technology for estimation of body composition. This paper presents a new 3D body imaging system, which was designed for enhanced portability, affordability, and functionality. In this system, stereo vision technology was used to satisfy the requirements for a simple hardware setup and fast image acquisitions. The portability of the system was created via a two-stand configuration, and the accuracy of body volume measurements was improved by customizing stereo matching and surface reconstruction algorithms that target specific problems in 3D body imaging. Body measurement functions dedicated to body composition assessment also were developed. The overall performance of the system was evaluated in human subjects by comparison to other conventional anthropometric methods, as well as air displacement plethysmography, for body fat assessment.

  16. Estimation of Human Power Output from Maximal Vertical Jump and Body Mass

    DTIC Science & Technology

    1988-01-01

    Medicine and Physical Fitness, 23(3):326-332, 1983. 2. Enoka, R.M. Neuromechanical Basis of Kinesiology. Human Kinetics , Champaign Illinois, 1988, pp. 6...1974, pp. 257-258. 5. Kirkendall, D.R., J.J. Gruber, and R.E. Johnson. Measurement and evaluation for physical educators, 2nd edition. Human Kinetics , Champaign

  17. 75 FR 47475 - Acetamiprid, Mepiquat; Order Denying NRDC’s Objections on Remand: Environmental Protection Agency

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-06

    ... milligrams of pesticide per kilogram of human body weight per day (mg/ kg/day).) Suppose the safe level of... of concern''), how EPA measures human exposure to pesticides, and how hazard, level of concern conclusions, and human exposure estimates are combined to evaluate risk. Further, this unit presents...

  18. 77 FR 72254 - New Animal Drugs; Updating Tolerances for Residues of New Animal Drugs in Food

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-05

    ... concentrations, FDA considered food consumption values and human body weight. Consumption was estimated as a... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Parts 500, 520, 522... for the Secretary of Health and Human Services (the Secretary) to establish and publish regulations...

  19. Qualitative human body composition analysis assessed with bioelectrical impedance.

    PubMed

    Talluri, T

    1998-12-01

    Body composition is generally aiming at quantitative estimates of fat mass, inadequate to assess nutritional states that on the other hand are well defined by the intra/extra cellular masses proportion (ECM/BCM). Direct measures performed with phase sensitive bioelectrical impedance analyzers can be used to define the current distribution in normal and abnormal populations. Phase angle and reactance nomogram is directly reflecting the ECM/BCM pathways proportions and body impedance analysis (BIA) is also validated to estimate the individual content of body cell mass (BCM). A new body cell mass index (BCMI) obtained dividing the weight of BCM in kilograms by the body surface in square meters is confronted to the scatterplot distribution of phase angle and reactance values obtained from controls and patients, and proposed as a qualitative approach to identify abnormal ECM/BCM ratios and nutritional states.

  20. Can blind persons accurately assess body size from the voice?

    PubMed

    Pisanski, Katarzyna; Oleszkiewicz, Anna; Sorokowska, Agnieszka

    2016-04-01

    Vocal tract resonances provide reliable information about a speaker's body size that human listeners use for biosocial judgements as well as speech recognition. Although humans can accurately assess men's relative body size from the voice alone, how this ability is acquired remains unknown. In this study, we test the prediction that accurate voice-based size estimation is possible without prior audiovisual experience linking low frequencies to large bodies. Ninety-one healthy congenitally or early blind, late blind and sighted adults (aged 20-65) participated in the study. On the basis of vowel sounds alone, participants assessed the relative body sizes of male pairs of varying heights. Accuracy of voice-based body size assessments significantly exceeded chance and did not differ among participants who were sighted, or congenitally blind or who had lost their sight later in life. Accuracy increased significantly with relative differences in physical height between men, suggesting that both blind and sighted participants used reliable vocal cues to size (i.e. vocal tract resonances). Our findings demonstrate that prior visual experience is not necessary for accurate body size estimation. This capacity, integral to both nonverbal communication and speech perception, may be present at birth or may generalize from broader cross-modal correspondences. © 2016 The Author(s).

  1. Can blind persons accurately assess body size from the voice?

    PubMed Central

    Oleszkiewicz, Anna; Sorokowska, Agnieszka

    2016-01-01

    Vocal tract resonances provide reliable information about a speaker's body size that human listeners use for biosocial judgements as well as speech recognition. Although humans can accurately assess men's relative body size from the voice alone, how this ability is acquired remains unknown. In this study, we test the prediction that accurate voice-based size estimation is possible without prior audiovisual experience linking low frequencies to large bodies. Ninety-one healthy congenitally or early blind, late blind and sighted adults (aged 20–65) participated in the study. On the basis of vowel sounds alone, participants assessed the relative body sizes of male pairs of varying heights. Accuracy of voice-based body size assessments significantly exceeded chance and did not differ among participants who were sighted, or congenitally blind or who had lost their sight later in life. Accuracy increased significantly with relative differences in physical height between men, suggesting that both blind and sighted participants used reliable vocal cues to size (i.e. vocal tract resonances). Our findings demonstrate that prior visual experience is not necessary for accurate body size estimation. This capacity, integral to both nonverbal communication and speech perception, may be present at birth or may generalize from broader cross-modal correspondences. PMID:27095264

  2. The Effect of Body Mass on Outdoor Adult Human Decomposition.

    PubMed

    Roberts, Lindsey G; Spencer, Jessica R; Dabbs, Gretchen R

    2017-09-01

    Forensic taphonomy explores factors impacting human decomposition. This study investigated the effect of body mass on the rate and pattern of adult human decomposition. Nine males and three females aged 49-95 years ranging in mass from 73 to 159 kg who were donated to the Complex for Forensic Anthropology Research between December 2012 and September 2015 were included in this study. Kelvin accumulated degree days (KADD) were used to assess the thermal energy required for subjects to reach several total body score (TBS) thresholds: early decomposition (TBS ≥6.0), TBS ≥12.5, advanced decomposition (TBS ≥19.0), TBS ≥23.0, and skeletonization (TBS ≥27.0). Results indicate no significant correlation between body mass and KADD at any TBS threshold. Body mass accounted for up to 24.0% of variation in decomposition rate depending on stage, and minor differences in decomposition pattern were observed. Body mass likely has a minimal impact on postmortem interval estimation. © 2017 American Academy of Forensic Sciences.

  3. A method to accurately estimate the muscular torques of human wearing exoskeletons by torque sensors.

    PubMed

    Hwang, Beomsoo; Jeon, Doyoung

    2015-04-09

    In exoskeletal robots, the quantification of the user's muscular effort is important to recognize the user's motion intentions and evaluate motor abilities. In this paper, we attempt to estimate users' muscular efforts accurately using joint torque sensor which contains the measurements of dynamic effect of human body such as the inertial, Coriolis, and gravitational torques as well as torque by active muscular effort. It is important to extract the dynamic effects of the user's limb accurately from the measured torque. The user's limb dynamics are formulated and a convenient method of identifying user-specific parameters is suggested for estimating the user's muscular torque in robotic exoskeletons. Experiments were carried out on a wheelchair-integrated lower limb exoskeleton, EXOwheel, which was equipped with torque sensors in the hip and knee joints. The proposed methods were evaluated by 10 healthy participants during body weight-supported gait training. The experimental results show that the torque sensors are to estimate the muscular torque accurately in cases of relaxed and activated muscle conditions.

  4. State-of-the-art measurements in human body composition: A moving frontier of clinical importance.

    PubMed

    Gallagher, D; Shaheen, I; Zafar, K

    2008-01-01

    The measurement of human body composition allows for the estimation of body tissues, organs, and their distributions in living persons without inflicting harm. From a nutritional perspective, the interest in body composition has increased multi-fold with the global increase in the prevalence of obesity and its complications. The latter has driven in part the need for improved measurement methods with greater sensitivity and precision. There is no single gold standard for body-composition measurements in-vivo. All methods incorporate assumptions that do not apply in all individuals and the more accurate models are derived by using a combination of measurements, thereby reducing the importance of each assumption. This review will discuss why the measurement of body composition or human phenotyping is important; discuss new areas where the measurement of body composition (human phenotyping) is recognized as having important application; and will summarize recent advances made in new methodology. Reference will also be made to areas we cannot yet measure due to the lack of appropriate measurement methodologies, most especially measurements methods that provide information on kinetic states (not just static state) and metabolic function.

  5. State-of-the-art measurements in human body composition: A moving frontier of clinical importance

    PubMed Central

    Gallagher, D.; Shaheen, I.; Zafar, K.

    2010-01-01

    The measurement of human body composition allows for the estimation of body tissues, organs, and their distributions in living persons without inflicting harm. From a nutritional perspective, the interest in body composition has increased multi-fold with the global increase in the prevalence of obesity and its complications. The latter has driven in part the need for improved measurement methods with greater sensitivity and precision. There is no single gold standard for body-composition measurements in-vivo. All methods incorporate assumptions that do not apply in all individuals and the more accurate models are derived by using a combination of measurements, thereby reducing the importance of each assumption. This review will discuss why the measurement of body composition or human phenotyping is important; discuss new areas where the measurement of body composition (human phenotyping) is recognized as having important application; and will summarize recent advances made in new methodology. Reference will also be made to areas we cannot yet measure due to the lack of appropriate measurement methodologies, most especially measurements methods that provide information on kinetic states (not just static state) and metabolic function. PMID:21234275

  6. Validation of a quantitative magnetic resonance method for measuring human body composition.

    PubMed

    Napolitano, Antonella; Miller, Sam R; Murgatroyd, Peter R; Coward, W Andrew; Wright, Antony; Finer, Nick; De Bruin, Tjerk W; Bullmore, Edward T; Nunez, Derek J

    2008-01-01

    To evaluate a novel quantitative magnetic resonance (QMR) methodology (EchoMRI-AH, Echo Medical Systems) for measurement of whole-body fat and lean mass in humans. We have studied (i) the in vitro accuracy and precision by measuring 18 kg Canola oil with and without 9 kg water (ii) the accuracy and precision of measures of simulated fat mass changes in human subjects (n = 10) and (iii) QMR fat and lean mass measurements compared to those obtained using the established 4-compartment (4-C) model method (n = 30). (i) QMR represented 18 kg of oil at 40 degrees C as 17.1 kg fat and 1 kg lean while at 30 degrees C 15.8 kg fat and 4.7 kg lean were reported. The s.d. of repeated estimates was 0.13 kg for fat and 0.23 kg for lean mass. Adding 9 kg of water reduced the fat estimates, increased misrepresentation of fat as lean, and degraded the precision. (ii) the simulated change in the fat mass of human volunteers was accurately represented, independently of added water. (iii) compared to the 4-C model, QMR underestimated fat and over-estimated lean mass. The extent of difference increased with body mass. The s.d. of repeated measurements increased with adiposity, from 0.25 kg (fat) and 0.51 kg (lean) with BMI <25 kg/m(2) to 0.43 kg and 0.81 kg respectively with BMI >30 kg/m(2). EchoMRI-AH prototype showed shortcomings in absolute accuracy and specificity of fat mass measures, but detected simulated body composition change accurately and with precision roughly three times better than current best measures. This methodology should reduce the study duration and cohort number needed to evaluate anti-obesity interventions.

  7. Infant dietary exposure to dioxins and dioxin-like compounds in Greece.

    PubMed

    Costopoulou, Danae; Vassiliadou, Irene; Leondiadis, Leondios

    2013-09-01

    The dietary exposure of infants to polychlorinated dibenzo dioxins and furans (PCDD/Fs) and dioxin like polychlorinated biphenyls (dl-PCBs) is an issue of great social impact. We investigated for the first time the dietary intake of these compounds in infants living in Greece. We included in our study two age groups: 0-6 months, when infants are fed exclusively by human milk and/or formula milk, and 6 to 12 months, when solid food is introduced to nutrition. We took into consideration analytical results for PCDD/Fs and dl-PCBs concentrations in the most popular infant formulae in the Greek market, previous data for mother milk concentrations of PCDD/Fs and dl-PCBs from Greece, and finally analytical data for fat-containing food products from the Greek market. In the first study group, it was found than in infants exclusively fed by breast milk, the calculated sum of PCDD/Fs and dioxin-like PCBs (60.3-80.4 TEQ pg/kg body weight) was significantly higher than that of infants that consume a combination of human milk and formula (31.2-41.6 TEQ pg/kg body weight). In the second study group, separate daily intake estimations were performed for babies receiving human milk (estimated total daily intake 19.76-24.95 TEQ pg/kg body weight) and formula milk (estimated total daily intake 1.60-2.24 TEQ pg/kg body weight). The risks of this exposure should not be overestimated because nursing is restricted to a limited period of human life and besides, the potential consumption of higher levels of dioxin-like compounds is fully compensated by the significant benefits of breast-feeding. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Total body skeletal muscle mass: estimation by creatine (methyl-d3) dilution in humans

    PubMed Central

    Walker, Ann C.; O'Connor-Semmes, Robin L.; Leonard, Michael S.; Miller, Ram R.; Stimpson, Stephen A.; Turner, Scott M.; Ravussin, Eric; Cefalu, William T.; Hellerstein, Marc K.; Evans, William J.

    2014-01-01

    Current methods for clinical estimation of total body skeletal muscle mass have significant limitations. We tested the hypothesis that creatine (methyl-d3) dilution (D3-creatine) measured by enrichment of urine D3-creatinine reveals total body creatine pool size, providing an accurate estimate of total body skeletal muscle mass. Healthy subjects with different muscle masses [n = 35: 20 men (19–30 yr, 70–84 yr), 15 postmenopausal women (51–62 yr, 70–84 yr)] were housed for 5 days. Optimal tracer dose was explored with single oral doses of 30, 60, or 100 mg D3-creatine given on day 1. Serial plasma samples were collected for D3-creatine pharmacokinetics. All urine was collected through day 5. Creatine and creatinine (deuterated and unlabeled) were measured by liquid chromatography mass spectrometry. Total body creatine pool size and muscle mass were calculated from D3-creatinine enrichment in urine. Muscle mass was also measured by magnetic resonance imaging (MRI), dual-energy x-ray absorptiometry (DXA), and traditional 24-h urine creatinine. D3-creatine was rapidly absorbed and cleared with variable urinary excretion. Isotopic steady-state of D3-creatinine enrichment in the urine was achieved by 30.7 ± 11.2 h. Mean steady-state enrichment in urine provided muscle mass estimates that correlated well with MRI estimates for all subjects (r = 0.868, P < 0.0001), with less bias compared with lean body mass assessment by DXA, which overestimated muscle mass compared with MRI. The dilution of an oral D3-creatine dose determined by urine D3-creatinine enrichment provides an estimate of total body muscle mass strongly correlated with estimates from serial MRI with less bias than total lean body mass assessment by DXA. PMID:24764133

  9. Total body skeletal muscle mass: estimation by creatine (methyl-d3) dilution in humans.

    PubMed

    Clark, Richard V; Walker, Ann C; O'Connor-Semmes, Robin L; Leonard, Michael S; Miller, Ram R; Stimpson, Stephen A; Turner, Scott M; Ravussin, Eric; Cefalu, William T; Hellerstein, Marc K; Evans, William J

    2014-06-15

    Current methods for clinical estimation of total body skeletal muscle mass have significant limitations. We tested the hypothesis that creatine (methyl-d3) dilution (D3-creatine) measured by enrichment of urine D3-creatinine reveals total body creatine pool size, providing an accurate estimate of total body skeletal muscle mass. Healthy subjects with different muscle masses [n = 35: 20 men (19-30 yr, 70-84 yr), 15 postmenopausal women (51-62 yr, 70-84 yr)] were housed for 5 days. Optimal tracer dose was explored with single oral doses of 30, 60, or 100 mg D3-creatine given on day 1. Serial plasma samples were collected for D3-creatine pharmacokinetics. All urine was collected through day 5. Creatine and creatinine (deuterated and unlabeled) were measured by liquid chromatography mass spectrometry. Total body creatine pool size and muscle mass were calculated from D3-creatinine enrichment in urine. Muscle mass was also measured by magnetic resonance imaging (MRI), dual-energy x-ray absorptiometry (DXA), and traditional 24-h urine creatinine. D3-creatine was rapidly absorbed and cleared with variable urinary excretion. Isotopic steady-state of D3-creatinine enrichment in the urine was achieved by 30.7 ± 11.2 h. Mean steady-state enrichment in urine provided muscle mass estimates that correlated well with MRI estimates for all subjects (r = 0.868, P < 0.0001), with less bias compared with lean body mass assessment by DXA, which overestimated muscle mass compared with MRI. The dilution of an oral D3-creatine dose determined by urine D3-creatinine enrichment provides an estimate of total body muscle mass strongly correlated with estimates from serial MRI with less bias than total lean body mass assessment by DXA. Copyright © 2014 the American Physiological Society.

  10. An improved silhouette for human pose estimation

    NASA Astrophysics Data System (ADS)

    Hawes, Anthony H.; Iftekharuddin, Khan M.

    2017-08-01

    We propose a novel method for analyzing images that exploits the natural lines of a human poses to find areas where self-occlusion could be present. Errors caused by self-occlusion cause several modern human pose estimation methods to mis-identify body parts, which reduces the performance of most action recognition algorithms. Our method is motivated by the observation that, in several cases, occlusion can be reasoned using only boundary lines of limbs. An intelligent edge detection algorithm based on the above principle could be used to augment the silhouette with information useful for pose estimation algorithms and push forward progress on occlusion handling for human action recognition. The algorithm described is applicable to computer vision scenarios involving 2D images and (appropriated flattened) 3D images.

  11. Investigation of in-body path loss in different human subjects for localization of capsule endoscope.

    PubMed

    Ara, Perzila; Cheng, Shaokoon; Heimlich, Michael; Dutkiewicz, Eryk

    2015-01-01

    Recent developments in capsule endoscopy have highlighted the need for accurate techniques to estimate the location of a capsule endoscope. A highly accurate location estimation of a capsule endoscope in the gastrointestinal (GI) tract in the range of several millimeters is a challenging task. This is mainly because the radio-frequency signals encounter high loss and a highly dynamic channel propagation environment. Therefore, an accurate path-loss model is required for the development of accurate localization algorithms. This paper presents an in-body path-loss model for the human abdomen region at 2.4 GHz frequency. To develop the path-loss model, electromagnetic simulations using the Finite-Difference Time-Domain (FDTD) method were carried out on two different anatomical human models. A mathematical expression for the path-loss model was proposed based on analysis of the measured loss at different capsule locations inside the small intestine. The proposed path-loss model is a good approximation to model in-body RF propagation, since the real measurements are quite infeasible for the capsule endoscopy subject.

  12. Lumbar joint torque estimation based on simplified motion measurement using multiple inertial sensors.

    PubMed

    Miyajima, Saori; Tanaka, Takayuki; Imamura, Yumeko; Kusaka, Takashi

    2015-01-01

    We estimate lumbar torque based on motion measurement using only three inertial sensors. First, human motion is measured by a 6-axis motion tracking device that combines a 3-axis accelerometer and a 3-axis gyroscope placed on the shank, thigh, and back. Next, the lumbar joint torque during the motion is estimated by kinematic musculoskeletal simulation. The conventional method for estimating joint torque uses full body motion data measured by an optical motion capture system. However, in this research, joint torque is estimated by using only three link angles of the body, thigh, and shank. The utility of our method was verified by experiments. We measured motion of bendung knee and waist simultaneously. As the result, we were able to estimate the lumbar joint torque from measured motion.

  13. Height and body mass influence on human body outlines: a quantitative approach using an elliptic Fourier analysis.

    PubMed

    Courtiol, Alexandre; Ferdy, Jean Baptiste; Godelle, Bernard; Raymond, Michel; Claude, Julien

    2010-05-01

    Many studies use representations of human body outlines to study how individual characteristics, such as height and body mass, affect perception of body shape. These typically involve reality-based stimuli (e.g., pictures) or manipulated stimuli (e.g., drawings). These two classes of stimuli have important drawbacks that limit result interpretations. Realistic stimuli vary in terms of traits that are correlated, which makes it impossible to assess the effect of a single trait independently. In addition, manipulated stimuli usually do not represent realistic morphologies. We describe and examine a method based on elliptic Fourier descriptors to automatically predict and represent body outlines for a given set of predicted variables (e.g., sex, height, and body mass). We first estimate whether these predictive variables are significantly related to human outlines. We find that height and body mass significantly influence body shape. Unlike height, the effect of body mass on shape differs between sexes. Then, we show that we can easily build a regression model that creates hypothetical outlines for an arbitrary set of covariates. These statistically computed outlines are quite realistic and may be used as stimuli in future studies.

  14. Effects of body and organ size on absorbed dose: there is no standard patient. [Radiation dose distribution in patients following radionuclide administration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poston, J.W.

    1976-01-01

    The problem of estimating the absorbed dose to organs and tissues of the human body due to the presence of a radiopharmaceutical in one or more organs is discussed. Complications are introduced by the fact that the body is not homogeneous and in many cases the organ shapes are not regular. Publications of the MIRD Committee have provided a direct means of estimating the absorbed dose (or absorbed fraction) for a number of radioisotopes. These estimates are based on Monte Carlo calculations for monoenergetic photons distributed uniformly in organs of an adult phantom. The medical physicist finds that his patientmore » does not resemble the adult phantom. In addition, the absorbed fractions for the adult are not reasonable values for the child. This paper examines how these absorbed fraction estimates apply to a nonstandard patient. (auth)« less

  15. THE RESPONSE OF SOME HEALTH PHYSICS INSTRUMENTS TO SODIUM-24 AND CHLORINE- 38 ACTIVITIES IN POLYTHENE MANPHANTOMS AND THE HUMAN BODY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peabody, C.O.

    1963-12-01

    Measurements were made of the response of five commonly used health physics instruments when held near polythene man-phantoms filled with aqueous solutions containing sodium-24 and chlorine-38. The ratios of the wholebody chlorine-38 and sodium-24 activities are calculated for various periods of accidental human irradiation by neutrons. These ratios and the phantom results are used to estimate the response of the five instruments when held near the human body at various times after irradiation. Relative contributions of the chlorine-38 and sodium-24 to the instrument indications are listed. The tabulated data enable the instrument readings to be converted to wholebody sodium- 24more » activity at the time of irradiation. This may be used as a quick estimate of the degree of neutron irradiation. (auth)« less

  16. A nonintrusive temperature measuring system for estimating deep body temperature in bed.

    PubMed

    Sim, S Y; Lee, W K; Baek, H J; Park, K S

    2012-01-01

    Deep body temperature is an important indicator that reflects human being's overall physiological states. Existing deep body temperature monitoring systems are too invasive to apply to awake patients for a long time. Therefore, we proposed a nonintrusive deep body temperature measuring system. To estimate deep body temperature nonintrusively, a dual-heat-flux probe and double-sensor probes were embedded in a neck pillow. When a patient uses the neck pillow to rest, the deep body temperature can be assessed using one of the thermometer probes embedded in the neck pillow. We could estimate deep body temperature in 3 different sleep positions. Also, to reduce the initial response time of dual-heat-flux thermometer which measures body temperature in supine position, we employed the curve-fitting method to one subject. And thereby, we could obtain the deep body temperature in a minute. This result shows the possibility that the system can be used as practical temperature monitoring system with appropriate curve-fitting model. In the next study, we would try to establish a general fitting model that can be applied to all of the subjects. In addition, we are planning to extract meaningful health information such as sleep structure analysis from deep body temperature data which are acquired from this system.

  17. Human Bites in the Classroom: Incidence, Treatment, and Complications

    ERIC Educational Resources Information Center

    Conlon, Helen Acree

    2007-01-01

    It has been estimated that at least one half of the population will experience some type of bite in their lifetime. Human bites are the third leading cause of all bites seen in hospital emergency departments after dog and cat bites. Human bites can be the source of exposure to body fluids, transmission of communicable diseases, infections ranging…

  18. Estimation of Full-Body Poses Using Only Five Inertial Sensors: An Eager or Lazy Learning Approach?

    PubMed Central

    Wouda, Frank J.; Giuberti, Matteo; Bellusci, Giovanni; Veltink, Peter H.

    2016-01-01

    Human movement analysis has become easier with the wide availability of motion capture systems. Inertial sensing has made it possible to capture human motion without external infrastructure, therefore allowing measurements in any environment. As high-quality motion capture data is available in large quantities, this creates possibilities to further simplify hardware setups, by use of data-driven methods to decrease the number of body-worn sensors. In this work, we contribute to this field by analyzing the capabilities of using either artificial neural networks (eager learning) or nearest neighbor search (lazy learning) for such a problem. Sparse orientation features, resulting from sensor fusion of only five inertial measurement units with magnetometers, are mapped to full-body poses. Both eager and lazy learning algorithms are shown to be capable of constructing this mapping. The full-body output poses are visually plausible with an average joint position error of approximately 7 cm, and average joint angle error of 7∘. Additionally, the effects of magnetic disturbances typical in orientation tracking on the estimation of full-body poses was also investigated, where nearest neighbor search showed better performance for such disturbances. PMID:27983676

  19. Estimation of Full-Body Poses Using Only Five Inertial Sensors: An Eager or Lazy Learning Approach?

    PubMed

    Wouda, Frank J; Giuberti, Matteo; Bellusci, Giovanni; Veltink, Peter H

    2016-12-15

    Human movement analysis has become easier with the wide availability of motion capture systems. Inertial sensing has made it possible to capture human motion without external infrastructure, therefore allowing measurements in any environment. As high-quality motion capture data is available in large quantities, this creates possibilities to further simplify hardware setups, by use of data-driven methods to decrease the number of body-worn sensors. In this work, we contribute to this field by analyzing the capabilities of using either artificial neural networks (eager learning) or nearest neighbor search (lazy learning) for such a problem. Sparse orientation features, resulting from sensor fusion of only five inertial measurement units with magnetometers, are mapped to full-body poses. Both eager and lazy learning algorithms are shown to be capable of constructing this mapping. The full-body output poses are visually plausible with an average joint position error of approximately 7 cm, and average joint angle error of 7 ∘ . Additionally, the effects of magnetic disturbances typical in orientation tracking on the estimation of full-body poses was also investigated, where nearest neighbor search showed better performance for such disturbances.

  20. High-resolution Doppler model of the human gait

    NASA Astrophysics Data System (ADS)

    Geisheimer, Jonathan L.; Greneker, Eugene F., III; Marshall, William S.

    2002-07-01

    A high resolution Doppler model of the walking human was developed for analyzing the continuous wave (CW) radar gait signature. Data for twenty subjects were collected simultaneously using an infrared motion capture system along with a two channel 10.525 GHz CW radar. The motion capture system recorded three-dimensional coordinates of infrared markers placed on the body. These body marker coordinates were used as inputs to create the theoretical Doppler output using a model constructed in MATLAB. The outputs of the model are the simulated Doppler signals due to each of the major limbs and the thorax. An estimated radar cross section for each part of the body was assigned using the Lund & Browder chart of estimated body surface area. The resultant Doppler model was then compared with the actual recorded Doppler gait signature in the frequency domain using the spectrogram. Comparison of the two sets of data has revealed several identifiable biomechanical features in the radar gait signature due to leg and body motion. The result of the research shows that a wealth of information can be unlocked from the radar gait signature, which may be useful in security and biometric applications.

  1. Elevated serum level of human alkaline phosphatase in obesity.

    PubMed

    Khan, Abdul Rehman; Awan, Fazli Rabbi; Najam, Syeda Sadia; Islam, Mehboob; Siddique, Tehmina; Zain, Maryam

    2015-11-01

    To investigate a correlation between serum alkaline phosphatase level and body mass index in human subjects. The comparative cross-sectional study was carried out at the National Institute for Biotechnology and Genetic Engineering, Faisalabad, Pakistan, from April 2012 to June 2013. Blood serum alkaline phosphatase levels were estimated and the subjects were divided into three sub-groups on the basis of their body mass. normal weight (<25kg/m2), overweight (25-27kg/m2) and obese (>27kg/m2) subjects. The serum samples were used for the estimation of clinically important biochemical parameters, using commercial kits on clinical chemistry analyser. Of the 197 subjects, 97(49%) were obese and 100(51%) were non-obese. The serum alkaline phosphatase level increased in obese (214±6.4 IU/L) compared to the non-obese subjects (184.5±5 IU/L). Furthermore, a significant linear relationship (r=0.3;p-0.0001) was found between serum alkaline phosphatase and body mass index. Other biochemical variables were not correlated to the body mass index. Over activity and higher amounts of alkaline phosphatase were linked to the development of obesity.

  2. THE EFFECTS OF DISINFECTION ON PHARMACEUTICALS IN DRINKING WATER SUPPLIES

    EPA Science Inventory

    Pharmaceuticals are intended to be applied to or ingested by humans and animals, metabolized by their bodies, and excreted through urine or feces. However, it has been estimated that somewhere between 30 and 90% of administered active ingredients pass through the human and anima...

  3. Human decomposition and the reliability of a 'Universal' model for post mortem interval estimations.

    PubMed

    Cockle, Diane L; Bell, Lynne S

    2015-08-01

    Human decomposition is a complex biological process driven by an array of variables which are not clearly understood. The medico-legal community have long been searching for a reliable method to establish the post-mortem interval (PMI) for those whose deaths have either been hidden, or gone un-noticed. To date, attempts to develop a PMI estimation method based on the state of the body either at the scene or at autopsy have been unsuccessful. One recent study has proposed that two simple formulae, based on the level of decomposition humidity and temperature, could be used to accurately calculate the PMI for bodies outside, on or under the surface worldwide. This study attempted to validate 'Formula I' [1] (for bodies on the surface) using 42 Canadian cases with known PMIs. The results indicated that bodies exposed to warm temperatures consistently overestimated the known PMI by a large and inconsistent margin for Formula I estimations. And for bodies exposed to cold and freezing temperatures (less than 4°C), then the PMI was dramatically under estimated. The ability of 'Formulae II' to estimate the PMI for buried bodies was also examined using a set of 22 known Canadian burial cases. As these cases used in this study are retrospective, some of the data needed for Formula II was not available. The 4.6 value used in Formula II to represent the standard ratio of time that burial decelerates the rate of decomposition was examined. The average time taken to achieve each stage of decomposition both on, and under the surface was compared for the 118 known cases. It was found that the rate of decomposition was not consistent throughout all stages of decomposition. The rates of autolysis above and below the ground were equivalent with the buried cases staying in a state of putrefaction for a prolonged period of time. It is suggested that differences in temperature extremes and humidity levels between geographic regions may make it impractical to apply formulas developed in one region to any other region. These results also suggest that there are other variables, apart from temperature and humidity that may impact the rate of human decomposition. These variables, or complex of variables, are considered regionally specific. Neither of the Universal Formulae performed well, and our results do not support the proposition of Universality for PMI estimation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Efficiency of whole-body counter for various body size calculated by MCNP5 software.

    PubMed

    Krstic, D; Nikezic, D

    2012-11-01

    The efficiency of a whole-body counter for (137)Cs and (40)K was calculated using the MCNP5 code. The ORNL phantoms of a human body of different body sizes were applied in a sitting position in front of a detector. The aim was to investigate the dependence of efficiency on the body size (age) and the detector position with respect to the body and to estimate the accuracy of real measurements. The calculation work presented here is related to the NaI detector, which is available in the Serbian Whole-body Counter facility in Vinca Institute.

  5. Estimation of body mass index from the metrics of the first metatarsal

    NASA Astrophysics Data System (ADS)

    Dunn, Tyler E.

    Estimation of the biological profile from as many skeletal elements as possible is a necessity in both forensic and bioarchaeological contexts; this includes non-standard aspects of the biological profile, such as body mass index (BMI). BMI is a measure that allows for understanding of the composition of an individual and is traditionally divided into four groups: underweight, normal weight, overweight, and obese. BMI estimation incorporates both estimation of stature and body mass. The estimation of stature from skeletal elements is commonly included into the standard biological profile but the estimation of body mass needs to be further statistically validated to be consistently included. The bones of the foot, specifically the first metatarsal, may have the ability to estimate BMI given an allometric relationship to stature and the mechanical relationship to body mass. There are two commonly used methods for stature estimation, the anatomical method and the regression method. The anatomical method takes into account all of the skeletal elements that contribute to stature while the regression method relies on the allometric relationship between a skeletal element and living stature. A correlation between the metrics of the first metatarsal and living stature has been observed, and proposed as a method for valid stature estimation from the boney foot (Byers et al., 1989). Body mass estimation from skeletal elements relies on two theoretical frameworks: the morphometric and the mechanical approaches. The morphometric approach relies on the size relationship of the individual to body mass; the basic relationship between volume, density, and weight allows for body mass estimation. The body is thought of as a cylinder, and in order to understand the volume of this cylinder the diameter is needed. A commonly used proxy for this in the human body is skeletal bi-iliac breadth from rearticulated pelvic girdle. The mechanical method of body mass estimation relies on the ideas of biomechanical bone remodeling; the elements of the skeleton that are under higher forces, including weight, will remodel to minimize stress. A commonly used metric for the mechanical method of body mass estimation is the diameter of the head of the femur. The foot experiences nearly the entire weight force of the individual at any point in the gait cycle and is subject to the biomechanical remodeling that this force would induce. Therefore, the application of the mechanical framework for body mass estimation could stand true for the elements of the foot. The morphometric and mechanical approaches have been validated against one another on a large, geographically disparate population (Auerbach and Ruff, 2004), but have yet to be validated on a sample of known body mass. DeGroote and Humphrey (2011) test the ability of the first metatarsal to estimate femoral head diameter, body mass, and femoral length. The estimated femoral head diameter from the first metatarsal is used to estimate body mass via the morphometric approach and the femoral length is used to estimate living stature. The authors find that body mass and stature estimation methods from more commonly used skeletal elements compared well with the methods developed from the first metatarsal. This study examines 388 `White' individuals from the William M. Bass donated skeletal collection to test the reliability of the body mass estimates from femoral head diameter and bi-iliac breadth, stature from maximum femoral length, and body mass and stature from the metrics of the first metatarsal. This sample included individuals from all four of the BMI classes. This study finds that all of the skeletal indicators compare well with one another; there is no statistical difference in the stature estimates from the first metatarsal and the maximum length of the femur, and there is no statistical between all three of the body mass estimation methods. When compared to the forensic estimates of stature neither of the tested methods had statistical difference. Conversely, when the body mass estimates are compared to forensic body mass there was a statistical difference and when further investigated the most difference in the body mass estimates was in the extremes of body mass (the underweight and obese categories). These findings indicate that the estimation of stature from both the maximum femoral length and the metrics of the metatarsal are accurate methods. Furthermore, the estimation of body mass is accurate when the individual is in the middle range of the BMI spectrum while these methods for outlying individuals are inaccurate. These findings have implications for the application of stature and body mass estimation in the fields of bioarchaeology, forensic anthropology, and paleoanthropology.

  6. Morphological analysis of the hindlimb in apes and humans. I. Muscle architecture.

    PubMed

    Payne, R C; Crompton, R H; Isler, K; Savage, R; Vereecke, E E; Günther, M M; Thorpe, S K S; D'Août, K

    2006-06-01

    We present quantitative data on the hindlimb musculature of Pan paniscus, Gorilla gorilla gorilla, Gorilla gorilla graueri, Pongo pygmaeus abelii and Hylobates lar and discuss the findings in relation to the locomotor habits of each. Muscle mass and fascicle length data were obtained for all major hindlimb muscles. Physiological cross-sectional area (PCSA) was estimated. Data were normalized assuming geometric similarity to allow for comparison of animals of different size/species. Muscle mass scaled closely to (body mass)(1.0) and fascicle length scaled closely to (body mass)(0.3) in most species. However, human hindlimb muscles were heavy and had short fascicles per unit body mass when compared with non-human apes. Gibbon hindlimb anatomy shared some features with human hindlimbs that were not observed in the non-human great apes: limb circumferences tapered from proximal-to-distal, fascicle lengths were short per unit body mass and tendons were relatively long. Non-human great ape hindlimb muscles were, by contrast, characterized by long fascicles arranged in parallel, with little/no tendon of insertion. Such an arrangement of muscle architecture would be useful for locomotion in a three dimensionally complex arboreal environment.

  7. Morphological analysis of the hindlimb in apes and humans. I. Muscle architecture

    PubMed Central

    Payne, R C; Crompton, R H; Isler, K; Savage, R; Vereecke, E E; Günther, M M; Thorpe, S K S; D'Août, K

    2006-01-01

    We present quantitative data on the hindlimb musculature of Pan paniscus, Gorilla gorilla gorilla, Gorilla gorilla graueri, Pongo pygmaeus abelii and Hylobates lar and discuss the findings in relation to the locomotor habits of each. Muscle mass and fascicle length data were obtained for all major hindlimb muscles. Physiological cross-sectional area (PCSA) was estimated. Data were normalized assuming geometric similarity to allow for comparison of animals of different size/species. Muscle mass scaled closely to (body mass)1.0 and fascicle length scaled closely to (body mass)0.3 in most species. However, human hindlimb muscles were heavy and had short fascicles per unit body mass when compared with non-human apes. Gibbon hindlimb anatomy shared some features with human hindlimbs that were not observed in the non-human great apes: limb circumferences tapered from proximal-to-distal, fascicle lengths were short per unit body mass and tendons were relatively long. Non-human great ape hindlimb muscles were, by contrast, characterized by long fascicles arranged in parallel, with little/no tendon of insertion. Such an arrangement of muscle architecture would be useful for locomotion in a three dimensionally complex arboreal environment. PMID:16761973

  8. The relationships among jaw-muscle fiber architecture, jaw morphology, and feeding behavior in extant apes and modern humans.

    PubMed

    Taylor, Andrea B; Vinyard, Christopher J

    2013-05-01

    The jaw-closing muscles are responsible for generating many of the forces and movements associated with feeding. Muscle physiologic cross-sectional area (PCSA) and fiber length are two architectural parameters that heavily influence muscle function. While there have been numerous comparative studies of hominoid and hominin craniodental and mandibular morphology, little is known about hominoid jaw-muscle fiber architecture. We present novel data on masseter and temporalis internal muscle architecture for small- and large-bodied hominoids. Hominoid scaling patterns are evaluated and compared with representative New- (Cebus) and Old-World (Macaca) monkeys. Variation in hominoid jaw-muscle fiber architecture is related to both absolute size and allometry. PCSAs scale close to isometry relative to jaw length in anthropoids, but likely with positive allometry in hominoids. Thus, large-bodied apes may be capable of generating both absolutely and relatively greater muscle forces compared with smaller-bodied apes and monkeys. Compared with extant apes, modern humans exhibit a reduction in masseter PCSA relative to condyle-M1 length but retain relatively long fibers, suggesting humans may have sacrificed relative masseter muscle force during chewing without appreciably altering muscle excursion/contraction velocity. Lastly, craniometric estimates of PCSAs underestimate hominoid masseter and temporalis PCSAs by more than 50% in gorillas, and overestimate masseter PCSA by as much as 30% in humans. These findings underscore the difficulty of accurately estimating jaw-muscle fiber architecture from craniometric measures and suggest models of fossil hominin and hominoid bite forces will be improved by incorporating architectural data in estimating jaw-muscle forces. Copyright © 2013 Wiley Periodicals, Inc.

  9. A Method to Accurately Estimate the Muscular Torques of Human Wearing Exoskeletons by Torque Sensors

    PubMed Central

    Hwang, Beomsoo; Jeon, Doyoung

    2015-01-01

    In exoskeletal robots, the quantification of the user’s muscular effort is important to recognize the user’s motion intentions and evaluate motor abilities. In this paper, we attempt to estimate users’ muscular efforts accurately using joint torque sensor which contains the measurements of dynamic effect of human body such as the inertial, Coriolis, and gravitational torques as well as torque by active muscular effort. It is important to extract the dynamic effects of the user’s limb accurately from the measured torque. The user’s limb dynamics are formulated and a convenient method of identifying user-specific parameters is suggested for estimating the user’s muscular torque in robotic exoskeletons. Experiments were carried out on a wheelchair-integrated lower limb exoskeleton, EXOwheel, which was equipped with torque sensors in the hip and knee joints. The proposed methods were evaluated by 10 healthy participants during body weight-supported gait training. The experimental results show that the torque sensors are to estimate the muscular torque accurately in cases of relaxed and activated muscle conditions. PMID:25860074

  10. Theoretical assessment of the maximum obtainable power in wireless power transfer constrained by human body exposure limits in a typical room scenario.

    PubMed

    Chen, Xi Lin; De Santis, Valerio; Umenei, Aghuinyue Esai

    2014-07-07

    In this study, the maximum received power obtainable through wireless power transfer (WPT) by a small receiver (Rx) coil from a relatively large transmitter (Tx) coil is numerically estimated in the frequency range from 100 kHz to 10 MHz based on human body exposure limits. Analytical calculations were first conducted to determine the worst-case coupling between a homogeneous cylindrical phantom with a radius of 0.65 m and a Tx coil positioned 0.1 m away with the radius ranging from 0.25 to 2.5 m. Subsequently, three high-resolution anatomical models were employed to compute the peak induced field intensities with respect to various Tx coil locations and dimensions. Based on the computational results, scaling factors which correlate the cylindrical phantom and anatomical model results were derived. Next, the optimal operating frequency, at which the highest transmitter source power can be utilized without exceeding the exposure limits, is found to be around 2 MHz. Finally, a formulation is proposed to estimate the maximum obtainable power of WPT in a typical room scenario while adhering to the human body exposure compliance mandates.

  11. Theoretical assessment of the maximum obtainable power in wireless power transfer constrained by human body exposure limits in a typical room scenario

    NASA Astrophysics Data System (ADS)

    Chen, Xi Lin; De Santis, Valerio; Esai Umenei, Aghuinyue

    2014-07-01

    In this study, the maximum received power obtainable through wireless power transfer (WPT) by a small receiver (Rx) coil from a relatively large transmitter (Tx) coil is numerically estimated in the frequency range from 100 kHz to 10 MHz based on human body exposure limits. Analytical calculations were first conducted to determine the worst-case coupling between a homogeneous cylindrical phantom with a radius of 0.65 m and a Tx coil positioned 0.1 m away with the radius ranging from 0.25 to 2.5 m. Subsequently, three high-resolution anatomical models were employed to compute the peak induced field intensities with respect to various Tx coil locations and dimensions. Based on the computational results, scaling factors which correlate the cylindrical phantom and anatomical model results were derived. Next, the optimal operating frequency, at which the highest transmitter source power can be utilized without exceeding the exposure limits, is found to be around 2 MHz. Finally, a formulation is proposed to estimate the maximum obtainable power of WPT in a typical room scenario while adhering to the human body exposure compliance mandates.

  12. A Layered Approach for Robust Spatial Virtual Human Pose Reconstruction Using a Still Image

    PubMed Central

    Guo, Chengyu; Ruan, Songsong; Liang, Xiaohui; Zhao, Qinping

    2016-01-01

    Pedestrian detection and human pose estimation are instructive for reconstructing a three-dimensional scenario and for robot navigation, particularly when large amounts of vision data are captured using various data-recording techniques. Using an unrestricted capture scheme, which produces occlusions or breezing, the information describing each part of a human body and the relationship between each part or even different pedestrians must be present in a still image. Using this framework, a multi-layered, spatial, virtual, human pose reconstruction framework is presented in this study to recover any deficient information in planar images. In this framework, a hierarchical parts-based deep model is used to detect body parts by using the available restricted information in a still image and is then combined with spatial Markov random fields to re-estimate the accurate joint positions in the deep network. Then, the planar estimation results are mapped onto a virtual three-dimensional space using multiple constraints to recover any deficient spatial information. The proposed approach can be viewed as a general pre-processing method to guide the generation of continuous, three-dimensional motion data. The experiment results of this study are used to describe the effectiveness and usability of the proposed approach. PMID:26907289

  13. Genetic variance estimation with imputed variants finds negligible missing heritability for human height and body mass index

    PubMed Central

    Yang, Jian; Bakshi, Andrew; Zhu, Zhihong; Hemani, Gibran; Vinkhuyzen, Anna A.E.; Lee, Sang Hong; Robinson, Matthew R.; Perry, John R.B.; Nolte, Ilja M.; van Vliet-Ostaptchouk, Jana V.; Snieder, Harold; Esko, Tonu; Milani, Lili; Mägi, Reedik; Metspalu, Andres; Hamsten, Anders; Magnusson, Patrik K.E.; Pedersen, Nancy L.; Ingelsson, Erik; Soranzo, Nicole; Keller, Matthew C.; Wray, Naomi R.; Goddard, Michael E.; Visscher, Peter M.

    2015-01-01

    We propose a method (GREML-LDMS) to estimate heritability for human complex traits in unrelated individuals using whole-genome sequencing (WGS) data. We demonstrate using simulations based on WGS data that ~97% and ~68% of variation at common and rare variants, respectively, can be captured by imputation. Using the GREML-LDMS method, we estimate from 44,126 unrelated individuals that all ~17M imputed variants explain 56% (s.e. = 2.3%) of variance for height and 27% (s.e. = 2.5%) for body mass index (BMI), and find evidence that height- and BMI-associated variants have been under natural selection. Considering imperfect tagging of imputation and potential overestimation of heritability from previous family-based studies, heritability is likely to be 60–70% for height and 30–40% for BMI. Therefore, missing heritability is small for both traits. For further gene discovery of complex traits, a design with SNP arrays followed by imputation is more cost-effective than WGS at current prices. PMID:26323059

  14. Gated Sensor Fusion: A way to Improve the Precision of Ambulatory Human Body Motion Estimation.

    PubMed

    Olivares, Alberto; Górriz, J M; Ramírez, J; Olivares, Gonzalo

    2014-01-01

    Human body motion is usually variable in terms of intensity and, therefore, any Inertial Measurement Unit attached to a subject will measure both low and high angular rate and accelerations. This can be a problem for the accuracy of orientation estimation algorithms based on adaptive filters such as the Kalman filter, since both the variances of the process noise and the measurement noise are set at the beginning of the algorithm and remain constant during its execution. Setting fixed noise parameters burdens the adaptation capability of the filter if the intensity of the motion changes rapidly. In this work we present a conjoint novel algorithm which uses a motion intensity detector to dynamically vary the noise statistical parameters of different approaches of the Kalman filter. Results show that the precision of the estimated orientation in terms of the RMSE can be improved up to 29% with respect to the standard fixed-parameters approaches.

  15. A Single Camera Motion Capture System for Human-Computer Interaction

    NASA Astrophysics Data System (ADS)

    Okada, Ryuzo; Stenger, Björn

    This paper presents a method for markerless human motion capture using a single camera. It uses tree-based filtering to efficiently propagate a probability distribution over poses of a 3D body model. The pose vectors and associated shapes are arranged in a tree, which is constructed by hierarchical pairwise clustering, in order to efficiently evaluate the likelihood in each frame. Anew likelihood function based on silhouette matching is proposed that improves the pose estimation of thinner body parts, i. e. the limbs. The dynamic model takes self-occlusion into account by increasing the variance of occluded body-parts, thus allowing for recovery when the body part reappears. We present two applications of our method that work in real-time on a Cell Broadband Engine™: a computer game and a virtual clothing application.

  16. Human exposure to HBCD and TBBPA via indoor dust in Korea: Estimation of external exposure and body burden.

    PubMed

    Barghi, Mandana; Shin, Eun-Su; Kim, Jong-Chul; Choi, Sung-Deuk; Chang, Yoon-Seok

    2017-09-01

    Human exposure to brominated flame retardants (BFRs) such as hexabromocyclododecane (HBCD) and tetrabromobisphenol A (TBBPA) mainly occurs through diet and dust ingestion. In this study, the BFR concentrations in 124 vacuum dust samples of six categories of indoor environments (homes, offices, kindergartens, cars, schools, and public indoor environments) and 32 surface dust samples were investigated. The median ΣHBCD concentrations ranged from 106.30ngg -1 in home dust to 496.13ngg -1 in office dust. The TBBPA concentrations in indoor dust (from 78.87 to 463.81ngg -1 ) were among the highest compared to other countries because of the high market demand for this flame retardant in Korea. The TBBPA concentrations in surface dust of living rooms were significantly higher (p<0.05) than sleeping rooms, due to the presence of more electrical equipment in living rooms. The estimated daily intakes (EDI) of ΣHBCD and TBBPA (dust+diet) for toddlers were 6.18ngkg -1 bwd -1 and 2.54ngkg -1 bwd -1 , respectively. In general, the ΣHBCD estimated body burden of Korean adults showed good agreement with the reported ΣHBCD median concentrations in their sera. Since the developmental health effect of exposure to HBCD was categorized as "high hazard" by the US Environmental Protection Agency, the estimated high body burden of ΣHBCD in Korean toddlers (7.91ngg -1 lw) warns us of possible adverse effects on the development of essential systems in their bodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Transient interaction model of electromagnetic field generated by lightning current pulses and human body

    NASA Astrophysics Data System (ADS)

    Iváncsy, T.; Kiss, I.; Szücs, L.; Tamus, Z. Á.

    2015-10-01

    The lightning current generates time-varying magnetic field near the down- conductor and the down-conductors are mounted on the wall of the buildings where residential places might be situated. It is well known that the rapidly changing magnetic fields can generate dangerous eddy currents in the human body.The higher duration and gradient of the magnetic field can cause potentially life threatening cardiac stimulation. The coupling mechanism between the electromagnetic field and the human body is based on a well-known physical phenomena (e.g. Faradays law of induction). However, the calculation of the induced current is very complicated because the shape of the organs is complex and the determination of the material properties of living tissues is difficult, as well. Our previous study revealed that the cardiac stimulation is independent of the rising time of the lightning current and only the peak of the current counts. In this study, the authors introduce an improved model of the interaction of electromagnetic fields of lighting current near down-conductor and human body. Our previous models are based on the quasi stationer field calculations, the new improved model is a transient model. This is because the magnetic field around the down-conductor and in the human body can be determined more precisely, therefore the dangerous currents in the body can be estimated.

  18. Directional and sectional ride comfort estimation using an integrated human biomechanical-seat foam model

    NASA Astrophysics Data System (ADS)

    Mohajer, Navid; Abdi, Hamid; Nahavandi, Saeid; Nelson, Kyle

    2017-09-01

    In the methodology of objective measurement of ride comfort, application of a Human Biomechanical Model (HBM) is valuable for Whole Body Vibration (WBV) analysis. In this study, using a computational Multibody System (MBS) approach, development of a 3D passive HBM for a seated human is considered. For this purpose, the existing MBS-based HBMs of seated human are briefly reviewed first. The Equations of Motion (EoM) for the proposed model are then obtained and the simulation results are shown and compared with idealised ranges of experimental results suggested in the literature. The human-seat interaction is established using a nonlinear vibration model of foam with respect to the sectional behaviour of the seat foam. The developed system is then used for ride comfort estimation offered by a ride dynamic model. The effects of human weight, road class, and vehicle speed on the vibration of the human body segments in different directions are studied. It is shown that the there is a high correlation (more than 99.2%) between the vibration indices of the proposed HBM-foam model and the corresponding ISO 2631 WBV indices. In addition, relevant ISO 2631 indices that show a high correlation with the directional vibration of the head are identified.

  19. Measured body composition and geometrical data of four ``virtual family'' members for thermoregulatory modeling

    NASA Astrophysics Data System (ADS)

    Xu, Xiaojiang; Rioux, Timothy P.; MacLeod, Tynan; Patel, Tejash; Rome, Maxwell N.; Potter, Adam W.

    2017-03-01

    The purpose of this paper is to develop a database of tissue composition, distribution, volume, surface area, and skin thickness from anatomically correct human models, the virtual family. These models were based on high-resolution magnetic resonance imaging (MRI) of human volunteers, including two adults (male and female) and two children (boy and girl). In the segmented image dataset, each voxel is associated with a label which refers to a tissue type that occupies up that specific cubic millimeter of the body. The tissue volume was calculated from the number of the voxels with the same label. Volumes of 24 organs in body and volumes of 7 tissues in 10 specific body regions were calculated. Surface area was calculated from the collection of voxels that are touching the exterior air. Skin thicknesses were estimated from its volume and surface area. The differences between the calculated and original masses were about 3 % or less for tissues or organs that are important to thermoregulatory modeling, e.g., muscle, skin, and fat. This accurate database of body tissue distributions and geometry is essential for the development of human thermoregulatory models. Data derived from medical imaging provide new effective tools to enhance thermal physiology research and gain deeper insight into the mechanisms of how the human body maintains heat balance.

  20. Juvenile body mass estimation: A methodological evaluation.

    PubMed

    Cowgill, Libby

    2018-02-01

    Two attempts have been made to develop body mass prediction formulae specifically for immature remains: Ruff (Ruff, C.C., 2007, Body size prediction from juvenile skeletal remains. American Journal Physical Anthropology 133, 698-716) and Robbins et al. (Robbins, G., Sciulli, P.W., Blatt, S.H., 2010. Estimating body mass in subadult human skeletons. American Journal Physical Anthropology 143, 146-150). While both were developed from the same reference population, they differ in their independent variable selection: Ruff (2008) used measures of metaphyseal and articular surface size to predict body mass in immature remains, whereas Robbins et al. (2010) relied on cross-sectional properties. Both methods perform well on independent testing samples; however, differences between the two methods exist in the predicted values. This research evaluates the differences in the body mass estimates from these two methods in seven geographically diverse skeletal samples under the age of 18 (n = 461). The purpose of this analysis is not to assess which method performs with greater accuracy or precision; instead, differences between the two methods are used as a heuristic device to focus attention on the unique challenges affecting the prediction of immature body mass estimates in particular. The two methods differ by population only in some cases, which may be a reflection of activity variation or nutritional status. In addition, cross-sectional properties almost always produce higher estimates than metaphyseal surface size across all age categories. This highlights the difficulty in teasing apart information related to body mass from that relevant to loading, particularly when the original reference population is urban/industrial. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. A Temperature-Based Bioimpedance Correction for Water Loss Estimation During Sports.

    PubMed

    Ring, Matthias; Lohmueller, Clemens; Rauh, Manfred; Mester, Joachim; Eskofier, Bjoern M

    2016-11-01

    The amount of total body water (TBW) can be estimated based on bioimpedance measurements of the human body. In sports, TBW estimations are of importance because mild water losses can impair muscular strength and aerobic endurance. Severe water losses can even be life threatening. TBW estimations based on bioimpedance, however, fail during sports because the increased body temperature corrupts bioimpedance measurements. Therefore, this paper proposes a machine learning method that eliminates the effects of increased temperature on bioimpedance and, consequently, reveals the changes in bioimpedance that are due to TBW loss. This is facilitated by utilizing changes in skin and core temperature. The method was evaluated in a study in which bioimpedance, temperature, and TBW loss were recorded every 15 min during a 2-h running workout. The evaluation demonstrated that the proposed method is able to reduce the error of TBW loss estimation by up to 71%, compared to the state of art. In the future, the proposed method in combination with portable bioimpedance devices might facilitate the development of wearable systems for continuous and noninvasive TBW loss monitoring during sports.

  2. Body mass prediction from skeletal frame size in elite athletes.

    PubMed

    Ruff, C B

    2000-12-01

    Body mass can be estimated from measures of skeletal frame size (stature and bi-iliac (maximum pelvic) breadth) fairly accurately in modern human populations. However, it is not clear whether such a technique will lead to systematic biases in body mass estimation when applied to earlier hominins. Here the stature/bi-iliac method is tested, using data available for modern Olympic and Olympic-caliber athletes, with the rationale that these individuals may be more representative of the general physique and degree of physical conditioning characteristic of earlier populations. The average percent prediction error of body mass among both male and female athletes is less than 3%, with males slightly underestimated and females slightly overestimated. Among males, the ratio of shoulder to hip (biacromial/bi-iliac) breadth is correlated with prediction error, while lower limb/trunk length has only a weak inconsistent effect. In both sexes, athletes in "weight" events (e.g. , shot put, weight-lifting), which emphasize strength, are underestimated, while those in more endurance-related events (e.g., long distance running) are overestimated. It is likely that the environmental pressures facing earlier hominins would have favored more generalized physiques adapted for a combination of strength, speed, agility, and endurance. The events most closely approximating these requirements in Olympic athletes are the decathlon, pentathlon, and wrestling, all of which have average percent prediction errors of body mass of 5% or less. Thus, "morphometric" estimation of body mass from skeletal frame size appears to work reasonably well in both "normal" and highly athletic modern humans, increasing confidence that the technique will also be applicable to earlier hominins. Copyright 2000 Wiley-Liss, Inc.

  3. Accelerometer-based on-body sensor localization for health and medical monitoring applications

    PubMed Central

    Vahdatpour, Alireza; Amini, Navid; Xu, Wenyao; Sarrafzadeh, Majid

    2011-01-01

    In this paper, we present a technique to recognize the position of sensors on the human body. Automatic on-body device localization ensures correctness and accuracy of measurements in health and medical monitoring systems. In addition, it provides opportunities to improve the performance and usability of ubiquitous devices. Our technique uses accelerometers to capture motion data to estimate the location of the device on the user’s body, using mixed supervised and unsupervised time series analysis methods. We have evaluated our technique with extensive experiments on 25 subjects. On average, our technique achieves 89% accuracy in estimating the location of devices on the body. In order to study the feasibility of classification of left limbs from right limbs (e.g., left arm vs. right arm), we performed analysis, based of which no meaningful classification was observed. Personalized ultraviolet monitoring and wireless transmission power control comprise two immediate applications of our on-body device localization approach. Such applications, along with their corresponding feasibility studies, are discussed. PMID:22347840

  4. Neurotoxicity of lead, methylmercury, and PCBs in relation to the Great Lakes.

    PubMed Central

    Rice, D C

    1995-01-01

    There is ample evidence identifying lead, methylmercury, and polychlorinated biphenyls (PCBs) as neurotoxic agents. A large body of data on the neurotoxicity of lead, based on both epidemiologic studies in children and animal models of developmental exposure, reveals that body burdens of lead typical of people in industrialized environments produce behavioral impairment. Methylmercury was identified as a neurotoxicant in both adults and the developing organism based on episodes of human poisoning: these effects have been replicated and extended in animals. High-dose PCB exposure was recognized as a developmental toxicant as a result of several episodes of contamination of cooking oil. The threshold for PCB neurotoxicity in humans is less clear, although research in animals suggests that relatively low-level exposure produces behavioral impairment and other toxic effects. Tissue levels in fish below which human health would not be adversely affected were estimated for methylmercury and PCBs based on calculated reference doses (RfDs) and estimated fish intake. Present levels in fish tissue in the Great Lakes exceed these levels for both neurotoxicants. Great Lakes fish and water do not pose a particular hazard for increased lead intake. However, the fact that the present human body burden is in a range at which functional deficits are probable suggests that efforts should be made to eliminate point sources of lead contamination in the Great Lakes basin. PMID:8635443

  5. Multiple regression based imputation for individualizing template human model from a small number of measured dimensions.

    PubMed

    Nohara, Ryuki; Endo, Yui; Murai, Akihiko; Takemura, Hiroshi; Kouchi, Makiko; Tada, Mitsunori

    2016-08-01

    Individual human models are usually created by direct 3D scanning or deforming a template model according to the measured dimensions. In this paper, we propose a method to estimate all the necessary dimensions (full set) for the human model individualization from a small number of measured dimensions (subset) and human dimension database. For this purpose, we solved multiple regression equation from the dimension database given full set dimensions as the objective variable and subset dimensions as the explanatory variables. Thus, the full set dimensions are obtained by simply multiplying the subset dimensions to the coefficient matrix of the regression equation. We verified the accuracy of our method by imputing hand, foot, and whole body dimensions from their dimension database. The leave-one-out cross validation is employed in this evaluation. The mean absolute errors (MAE) between the measured and the estimated dimensions computed from 4 dimensions (hand length, breadth, middle finger breadth at proximal, and middle finger depth at proximal) in the hand, 2 dimensions (foot length, breadth, and lateral malleolus height) in the foot, and 1 dimension (height) and weight in the whole body are computed. The average MAE of non-measured dimensions were 4.58% in the hand, 4.42% in the foot, and 3.54% in the whole body, while that of measured dimensions were 0.00%.

  6. Wind-chill-equivalent temperatures: regarding the impact due to the variability of the environmental convective heat transfer coefficient.

    PubMed

    Shitzer, Avraham

    2006-03-01

    The wind-chill index (WCI), developed in Antarctica in the 1940s and recently updated by the weather services in the USA and Canada, expresses the enhancement of heat loss in cold climates from exposed body parts, e.g., face, due to wind. The index provides a simple and practical means for assessing the thermal effects of wind on humans outdoors. It is also used for indicating weather conditions that may pose adverse risks of freezing at subfreezing environmental temperatures. Values of the WCI depend on a number of parameters, i.e, temperatures, physical properties of the air, wind speed, etc., and on insolation and evaporation. This paper focuses on the effects of various empirical correlations used in the literature for calculating the convective heat transfer coefficients between humans and their environment. Insolation and evaporation are not included in the presentation. Large differences in calculated values among these correlations are demonstrated and quantified. Steady-state wind-chill-equivalent temperatures (WCETs) are estimated by a simple, one-dimensional heat-conducting hollow-cylindrical model using these empirical correlations. Partial comparison of these values with the published "new" WCETs is presented. The variability of the estimated WCETs, due to different correlations employed to calculate them, is clearly demonstrated. The results of this study clearly suggest the need for establishing a "gold standard" for estimating convective heat exchange between exposed body elements and the cold and windy environment. This should be done prior to the introduction and adoption of further modifications to WCETs and indices. Correlations to estimate the convective heat transfer coefficients between exposed body parts of humans in windy and cold environments influence the WCETs and need to be standardized.

  7. Wind-chill-equivalent temperatures: regarding the impact due to the variability of the environmental convective heat transfer coefficient

    NASA Astrophysics Data System (ADS)

    Shitzer, Avraham

    2006-03-01

    The wind-chill index (WCI), developed in Antarctica in the 1940s and recently updated by the weather services in the USA and Canada, expresses the enhancement of heat loss in cold climates from exposed body parts, e.g., face, due to wind. The index provides a simple and practical means for assessing the thermal effects of wind on humans outdoors. It is also used for indicating weather conditions that may pose adverse risks of freezing at subfreezing environmental temperatures. Values of the WCI depend on a number of parameters, i.e, temperatures, physical properties of the air, wind speed, etc., and on insolation and evaporation. This paper focuses on the effects of various empirical correlations used in the literature for calculating the convective heat transfer coefficients between humans and their environment. Insolation and evaporation are not included in the presentation. Large differences in calculated values among these correlations are demonstrated and quantified. Steady-state wind-chill-equivalent temperatures (WCETs) are estimated by a simple, one-dimensional heat-conducting hollow-cylindrical model using these empirical correlations. Partial comparison of these values with the published “new” WCETs is presented. The variability of the estimated WCETs, due to different correlations employed to calculate them, is clearly demonstrated. The results of this study clearly suggest the need for establishing a “gold standard” for estimating convective heat exchange between exposed body elements and the cold and windy environment. This should be done prior to the introduction and adoption of further modifications to WCETs and indices. Correlations to estimate the convective heat transfer coefficients between exposed body parts of humans in windy and cold environments influence the WCETs and need to be standardized.

  8. Perceptual precision of passive body tilt is consistent with statistically optimal cue integration

    PubMed Central

    Karmali, Faisal; Nicoucar, Keyvan; Merfeld, Daniel M.

    2017-01-01

    When making perceptual decisions, humans have been shown to optimally integrate independent noisy multisensory information, matching maximum-likelihood (ML) limits. Such ML estimators provide a theoretic limit to perceptual precision (i.e., minimal thresholds). However, how the brain combines two interacting (i.e., not independent) sensory cues remains an open question. To study the precision achieved when combining interacting sensory signals, we measured perceptual roll tilt and roll rotation thresholds between 0 and 5 Hz in six normal human subjects. Primary results show that roll tilt thresholds between 0.2 and 0.5 Hz were significantly lower than predicted by a ML estimator that includes only vestibular contributions that do not interact. In this paper, we show how other cues (e.g., somatosensation) and an internal representation of sensory and body dynamics might independently contribute to the observed performance enhancement. In short, a Kalman filter was combined with an ML estimator to match human performance, whereas the potential contribution of nonvestibular cues was assessed using published bilateral loss patient data. Our results show that a Kalman filter model including previously proven canal-otolith interactions alone (without nonvestibular cues) can explain the observed performance enhancements as can a model that includes nonvestibular contributions. NEW & NOTEWORTHY We found that human whole body self-motion direction-recognition thresholds measured during dynamic roll tilts were significantly lower than those predicted by a conventional maximum-likelihood weighting of the roll angular velocity and quasistatic roll tilt cues. Here, we show that two models can each match this “apparent” better-than-optimal performance: 1) inclusion of a somatosensory contribution and 2) inclusion of a dynamic sensory interaction between canal and otolith cues via a Kalman filter model. PMID:28179477

  9. Application of overall dynamic body acceleration as a proxy for estimating the energy expenditure of grazing farm animals: relationship with heart rate.

    PubMed

    Miwa, Masafumi; Oishi, Kazato; Nakagawa, Yasuhiro; Maeno, Hiromichi; Anzai, Hiroki; Kumagai, Hajime; Okano, Kanji; Tobioka, Hisaya; Hirooka, Hiroyuki

    2015-01-01

    Estimating the energy expenditure of farm animals at pasture is important for efficient animal management. In recent years, an alternative technique for estimating energy expenditure by measuring body acceleration has been widely performed in wildlife and human studies, but the availability of the technique in farm animals has not yet been examined. In the present study, we tested the potential use of an acceleration index, overall dynamic body acceleration (ODBA), as a new proxy for estimating the energy expenditure of grazing farm animals (cattle, goats and sheep) at pasture with the simultaneous evaluation of a conventional proxy, heart rate. Body accelerations in three axes and heart rate for cows (n = 8, two breeds), goats (n = 6) and sheep (n = 5) were recorded, and the effect of ODBA calculated from the body accelerations on heart rate was analyzed. In addition, the effects of the two other activity indices, the number of steps and vectorial dynamic body acceleration (VeDBA), on heart rate were also investigated. The results of the comparison among three activity indices indicated that ODBA was the best predictor for heart rate. Although the relationship between ODBA and heart rate was different between the groups of species and breeds and between individuals (P<0.01), the difference could be explained by different body weights; a common equation could be established by correcting the body weights (M: kg): heart rate (beats/min) = 147.263∙M-0.141 + 889.640∙M-0.179∙ODBA (g). Combining this equation with the previously reported energy expenditure per heartbeat, we estimated the energy expenditure of the tested animals, and the results indicated that ODBA is a good proxy for estimating the energy expenditure of grazing farm animals across species and breeds. The utility and simplicity of the procedure with acceleration loggers could make the accelerometry technique a worthwhile option in field research and commercial farm use.

  10. Whole-body to tissue concentration ratios for use in biota dose assessments for animals.

    PubMed

    Yankovich, Tamara L; Beresford, Nicholas A; Wood, Michael D; Aono, Tasuo; Andersson, Pål; Barnett, Catherine L; Bennett, Pamela; Brown, Justin E; Fesenko, Sergey; Fesenko, J; Hosseini, Ali; Howard, Brenda J; Johansen, Mathew P; Phaneuf, Marcel M; Tagami, Keiko; Takata, Hyoe; Twining, John R; Uchida, Shigeo

    2010-11-01

    Environmental monitoring programs often measure contaminant concentrations in animal tissues consumed by humans (e.g., muscle). By comparison, demonstration of the protection of biota from the potential effects of radionuclides involves a comparison of whole-body doses to radiological dose benchmarks. Consequently, methods for deriving whole-body concentration ratios based on tissue-specific data are required to make best use of the available information. This paper provides a series of look-up tables with whole-body:tissue-specific concentration ratios for non-human biota. Focus was placed on relatively broad animal categories (including molluscs, crustaceans, freshwater fishes, marine fishes, amphibians, reptiles, birds and mammals) and commonly measured tissues (specifically, bone, muscle, liver and kidney). Depending upon organism, whole-body to tissue concentration ratios were derived for between 12 and 47 elements. The whole-body to tissue concentration ratios can be used to estimate whole-body concentrations from tissue-specific measurements. However, we recommend that any given whole-body to tissue concentration ratio should not be used if the value falls between 0.75 and 1.5. Instead, a value of one should be assumed.

  11. Footbridge system identification using wireless inertial measurement units for force and response measurements

    NASA Astrophysics Data System (ADS)

    Brownjohn, James Mark William; Bocian, Mateusz; Hester, David; Quattrone, Antonino; Hudson, William; Moore, Daniel; Goh, Sushma; Lim, Meng Sun

    2016-12-01

    With the main focus on safety, design of structures for vibration serviceability is often overlooked or mismanaged, resulting in some high profile structures failing publicly to perform adequately under human dynamic loading due to walking, running or jumping. A standard tool to inform better design, prove fitness for purpose before entering service and design retrofits is modal testing, a procedure that typically involves acceleration measurements using an array of wired sensors and force generation using a mechanical shaker. A critical but often overlooked aspect is using input (force) to output (response) relationships to enable estimation of modal mass, which is a key parameter directly controlling vibration levels in service. This paper describes the use of wireless inertial measurement units (IMUs), designed for biomechanics motion capture applications, for the modal testing of a 109 m footbridge. IMUs were first used for an output-only vibration survey to identify mode frequencies, shapes and damping ratios, then for simultaneous measurement of body accelerations of a human subject jumping to excite specific vibrations modes and build up bridge deck accelerations at the jumping location. Using the mode shapes and the vertical acceleration data from a suitable body landmark scaled by body mass, thus providing jumping force data, it was possible to create frequency response functions and estimate modal masses. The modal mass estimates for this bridge were checked against estimates obtained using an instrumented hammer and known mass distributions, showing consistency among the experimental estimates. Finally, the method was used in an applied research application on a short span footbridge where the benefits of logistical and operational simplicity afforded by the highly portable and easy to use IMUs proved extremely useful for an efficient evaluation of vibration serviceability, including estimation of modal masses.

  12. Dynamically adjustable foot-ground contact model to estimate ground reaction force during walking and running.

    PubMed

    Jung, Yihwan; Jung, Moonki; Ryu, Jiseon; Yoon, Sukhoon; Park, Sang-Kyoon; Koo, Seungbum

    2016-03-01

    Human dynamic models have been used to estimate joint kinetics during various activities. Kinetics estimation is in demand in sports and clinical applications where data on external forces, such as the ground reaction force (GRF), are not available. The purpose of this study was to estimate the GRF during gait by utilizing distance- and velocity-dependent force models between the foot and ground in an inverse-dynamics-based optimization. Ten males were tested as they walked at four different speeds on a force plate-embedded treadmill system. The full-GRF model whose foot-ground reaction elements were dynamically adjusted according to vertical displacement and anterior-posterior speed between the foot and ground was implemented in a full-body skeletal model. The model estimated the vertical and shear forces of the GRF from body kinematics. The shear-GRF model with dynamically adjustable shear reaction elements according to the input vertical force was also implemented in the foot of a full-body skeletal model. Shear forces of the GRF were estimated from body kinematics, vertical GRF, and center of pressure. The estimated full GRF had the lowest root mean square (RMS) errors at the slow walking speed (1.0m/s) with 4.2, 1.3, and 5.7% BW for anterior-posterior, medial-lateral, and vertical forces, respectively. The estimated shear forces were not significantly different between the full-GRF and shear-GRF models, but the RMS errors of the estimated knee joint kinetics were significantly lower for the shear-GRF model. Providing COP and vertical GRF with sensors, such as an insole-type pressure mat, can help estimate shear forces of the GRF and increase accuracy for estimation of joint kinetics. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Postmortem time estimation using body temperature and a finite-element computer model.

    PubMed

    den Hartog, Emiel A; Lotens, Wouter A

    2004-09-01

    In the Netherlands most murder victims are found 2-24 h after the crime. During this period, body temperature decrease is the most reliable method to estimate the postmortem time (PMT). Recently, two murder cases were analysed in which currently available methods did not provide a sufficiently reliable estimate of the PMT. In both cases a study was performed to verify the statements of suspects. For this purpose a finite-element computer model was developed that simulates a human torso and its clothing. With this model, changes to the body and the environment can also be modelled; this was very relevant in one of the cases, as the body had been in the presence of a small fire. In both cases it was possible to falsify the statements of the suspects by improving the accuracy of the PMT estimate. The estimated PMT in both cases was within the range of Henssge's model. The standard deviation of the PMT estimate was 35 min in the first case and 45 min in the second case, compared to 168 min (2.8 h) in Henssge's model. In conclusion, the model as presented here can have additional value for improving the accuracy of the PMT estimate. In contrast to the simple model of Henssge, the current model allows for increased accuracy when more detailed information is available. Moreover, the sensitivity of the predicted PMT for uncertainty in the circumstances can be studied, which is crucial to the confidence of the judge in the results.

  14. Simplified model of mean double step (MDS) in human body movement

    NASA Astrophysics Data System (ADS)

    Dusza, Jacek J.; Wawrzyniak, Zbigniew M.; Mugarra González, C. Fernando

    In this paper we present a simplified and useful model of the human body movement based on the full gait cycle description, called the Mean Double Step (MDS). It enables the parameterization and simplification of the human movement. Furthermore it allows a description of the gait cycle by providing standardized estimators to transform the gait cycle into a periodical movement process. Moreover the method of simplifying the MDS model and its compression are demonstrated. The simplification is achieved by reducing the number of bars of the spectrum and I or by reducing the number of samples describing the MDS both in terms of reducing their computational burden and their resources for the data storage. Our MDS model, which is applicable to the gait cycle method for examining patients, is non-invasive and provides the additional advantage of featuring a functional characterization of the relative or absolute movement of any part of the body.

  15. Vital Sign Monitoring Through the Back Using an UWB Impulse Radar With Body Coupled Antennas.

    PubMed

    Schires, Elliott; Georgiou, Pantelis; Lande, Tor Sverre

    2018-04-01

    Radar devices can be used in nonintrusive situations to monitor vital sign, through clothes or behind walls. By detecting and extracting body motion linked to physiological activity, accurate simultaneous estimations of both heart rate (HR) and respiration rate (RR) is possible. However, most research to date has focused on front monitoring of superficial motion of the chest. In this paper, body penetration of electromagnetic (EM) wave is investigated to perform back monitoring of human subjects. Using body-coupled antennas and an ultra-wideband (UWB) pulsed radar, in-body monitoring of lungs and heart motion was achieved. An optimised location of measurement in the back of a subject is presented, to enhance signal-to-noise ratio and limit attenuation of reflected radar signals. Phase-based detection techniques are then investigated for back measurements of vital sign, in conjunction with frequency estimation methods that reduce the impact of parasite signals. Finally, an algorithm combining these techniques is presented to allow robust and real-time estimation of both HR and RR. Static and dynamic tests were conducted, and demonstrated the possibility of using this sensor in future health monitoring systems, especially in the form of a smart car seat for driver monitoring.

  16. Estimating Lethal and Severe Toxic Effects in Minipigs Following 10, 60, and 180 Minutes of Whole-Body GB Vapor Exposure

    DTIC Science & Technology

    2006-03-01

    povidone-iodine) followed either by an application of isopropyl alcohol or a sporicidal agent. The surgical area was then covered with sterile drapes ...for Ten Minutes. MLRR 1952, 150. 20. Bide, R.W.; Armour , S.J.; Yee, E. Estimation of Human Toxicity from Animal Toxicity Data: GB Toxicity Reassessed

  17. Proton magnetic resonance spectroscopy for assessment of human body composition.

    PubMed

    Kamba, M; Kimura, K; Koda, M; Ogawa, T

    2001-02-01

    The usefulness of magnetic resonance spectroscopy (MRS)-based techniques for assessment of human body composition has not been established. We compared a proton MRS-based technique with the total body water (TBW) method to determine the usefulness of the former technique for assessment of human body composition. Proton magnetic resonance spectra of the chest to abdomen, abdomen to pelvis, and pelvis to thigh regions were obtained from 16 volunteers by using single, free induction decay measurement with a clinical magnetic resonance system operating at 1.5 T. The MRS-derived metabolite ratio was determined as the ratio of fat methyl and methylene proton resonance to water proton resonance. The peak areas for the chest to abdomen and the pelvis to thigh regions were normalized to an external reference (approximately 2200 g benzene) and a weighted average of the MRS-derived metabolite ratios for the 2 positions was calculated. TBW for each subject was determined by the deuterium oxide dilution technique. The MRS-derived metabolite ratios were significantly correlated with the ratio of body fat to lean body mass estimated by TBW. The MRS-derived metabolite ratio for the abdomen to pelvis region correlated best with the ratio of body fat to lean body mass on simple regression analyses (r = 0.918). The MRS-derived metabolite ratio for the abdomen to pelvis region and that for the pelvis to thigh region were selected for a multivariate regression model (R = 0.947, adjusted R(2) = 0.881). This MRS-based technique is sufficiently accurate for assessment of human body composition.

  18. Noninvasive estimation of fluid shifts between body compartments by measurement of bioelectric characteristics

    NASA Technical Reports Server (NTRS)

    Bishop, Phillip A.

    1989-01-01

    Previous research has established that bioelectrical characteristics of the human body reflect fluid status to some extent. It has been previously assumed that changes in electrical resistance (R) and reactance (X) are associated with changes in total body water (TBW). The purpose of the present pilot investigation was to assess the correspondence between body R and X and changes in estimated TBW and plasma volume during a period of bedrest (simulated weightlessness). R and X were measured pre-, during, and post- a 13 day bedrest status. Although a clear relationship was not elucidated, evidence was found suggesting that R and X reflect plasma volume rather than TBW. Indirect evidence provided by previous studies which investigated other aspects of the electrical/fluid relationship, also suggests the independence of TBW and electrical properties. With further research, a bioelectrical technique for noninvasively tracking fluid changes consequent to space flight may be developed.

  19. Insects found on a human cadaver in central Italy including the blowfly Calliphora loewi (Diptera, Calliphoridae), a new species of forensic interest.

    PubMed

    Vanin, S; Gherardi, M; Bugelli, V; Di Paolo, M

    2011-04-15

    In the case of unidentified bodies the estimation of the period since death or of the season of death plays an important role to focus the attention on a reduced number of people among the ones reported missing. Forensic entomology can be one of the most important methods for these estimations, as occurred in this case. Flies are typically the first insects to colonize a dead body. The case reported here concerns the colonisation by insects of a male body in advanced decay found during the winter in Central Italy. This case is of particular interest as few data are available on the entomological evidence in the cold season. In particular, in this case we recovered Calliphora loewi (Calliphoridae), a species never collected before on dead bodies in Southern Europe. Larvae of the black soldier fly Hermetia illucens (Stratiomyidae), pupae and larvae belonging to genus Hydrothea (Muscidae), and Necrobia rufipes (Cleridae) specimens were also collected. The estimated PMI enabled identification of the cadaver, confirmed by DNA analysis. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Using frequency analysis to improve the precision of human body posture algorithms based on Kalman filters.

    PubMed

    Olivares, Alberto; Górriz, J M; Ramírez, J; Olivares, G

    2016-05-01

    With the advent of miniaturized inertial sensors many systems have been developed within the last decade to study and analyze human motion and posture, specially in the medical field. Data measured by the sensors are usually processed by algorithms based on Kalman Filters in order to estimate the orientation of the body parts under study. These filters traditionally include fixed parameters, such as the process and observation noise variances, whose value has large influence in the overall performance. It has been demonstrated that the optimal value of these parameters differs considerably for different motion intensities. Therefore, in this work, we show that, by applying frequency analysis to determine motion intensity, and varying the formerly fixed parameters accordingly, the overall precision of orientation estimation algorithms can be improved, therefore providing physicians with reliable objective data they can use in their daily practice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Continuum Reconfigurable Parallel Robots for Surgery: Shape Sensing and State Estimation with Uncertainty.

    PubMed

    Anderson, Patrick L; Mahoney, Arthur W; Webster, Robert J

    2017-07-01

    This paper examines shape sensing for a new class of surgical robot that consists of parallel flexible structures that can be reconfigured inside the human body. Known as CRISP robots, these devices provide access to the human body through needle-sized entry points, yet can be configured into truss-like structures capable of dexterous movement and large force application. They can also be reconfigured as needed during a surgical procedure. Since CRISP robots are elastic, they will deform when subjected to external forces or other perturbations. In this paper, we explore how to combine sensor information with mechanics-based models for CRISP robots to estimate their shapes under applied loads. The end result is a shape sensing framework for CRISP robots that will enable future research on control under applied loads, autonomous motion, force sensing, and other robot behaviors.

  2. Physics-based Simulation of Human Posture Using 3D Whole Body Scanning Technology for Astronaut Space Suit Evaluation

    NASA Technical Reports Server (NTRS)

    Kim, Kyu-Jung

    2005-01-01

    Over the past few years high precision three-dimensional (3D) full body laser scanners have been developed to be used as a powerful anthropometry tool for quantification of the morphology of the human body. The full body scanner can quickly extract body characteristics in non-contact fashion. It is required for the Anthropometry and Biomechanics Facility (ABF) to have capabilities for kinematics simulation of a digital human at various postures whereas the laser scanner only allows capturing a single static posture at each time. During this summer fellowship period a theoretical study has been conducted to estimate an arbitrary posture with a series of example postures through finite element (FE) approximation and found that four-point isoparametric FE approximation would result in reasonable maximum position errors less than 5%. Subsequent pilot scan experiments demonstrated that a bead marker with a nominal size of 6 mm could be used as a marker for digitizing 3-D coordinates of anatomical landmarks for further kinematic analysis. Two sessions of human subject testing were conducted for reconstruction of an arbitrary postures from a set of example postures for each joint motion for the forearm/hand complex and the whole upper extremity.

  3. Hand Pose Estimation by Fusion of Inertial and Magnetic Sensing Aided by a Permanent Magnet.

    PubMed

    Kortier, Henk G; Antonsson, Jacob; Schepers, H Martin; Gustafsson, Fredrik; Veltink, Peter H

    2015-09-01

    Tracking human body motions using inertial sensors has become a well-accepted method in ambulatory applications since the subject is not confined to a lab-bounded volume. However, a major drawback is the inability to estimate relative body positions over time because inertial sensor information only allows position tracking through strapdown integration, but does not provide any information about relative positions. In addition, strapdown integration inherently results in drift of the estimated position over time. We propose a novel method in which a permanent magnet combined with 3-D magnetometers and 3-D inertial sensors are used to estimate the global trunk orientation and relative pose of the hand with respect to the trunk. An Extended Kalman Filter is presented to fuse estimates obtained from inertial sensors with magnetic updates such that the position and orientation between the human hand and trunk as well as the global trunk orientation can be estimated robustly. This has been demonstrated in multiple experiments in which various hand tasks were performed. The most complex task in which simultaneous movements of both trunk and hand were performed resulted in an average rms position difference with an optical reference system of 19.7±2.2 mm whereas the relative trunk-hand and global trunk orientation error was 2.3±0.9 and 8.6±8.7 deg respectively.

  4. Overview of physiological principles to support thermal balance and comfort of astronauts in open space and on planetary surfaces

    NASA Astrophysics Data System (ADS)

    Koscheyev, Victor S.; Coca, Aitor; Leon, Gloria R.

    2007-02-01

    Although specialists have attempted to improve the space suit to provide better protection in open space or on planetary surfaces, there has been a relative lack of attention to features of human thermoregulatory processes that influence comfort and therefore have an impact on the effectiveness of protective equipment. Our findings showed that different body tissues transfer heat in/out of the body in a different manner. There are also individual differences in thermal transfer through body areas with different proportions of tissues; therefore, data on the thermal profile of each astronaut needs to be used to estimate the optimal body areas for heat/cold transfer in and out of the body in an individually tailored cooling/warming garment. Principles for supporting thermal comfort in space were formulated based on a series of studies to evaluate the human body's response to uniform/nonuniform thermal conditions on the body surface. We conclude that future space suit design and comfort support of astronauts can be easier and more effective if these principles are incorporated.

  5. People watching: The perception of the relative body proportions of the self and others.

    PubMed

    Linkenauger, Sally A; Kirby, Laura R; McCulloch, Kathleen C; Longo, Matthew R

    2017-07-01

    We have an abundance of perceptual information from multiple modalities specifying our body proportions. Consequently, it seems reasonable for researchers to assume that we have an accurate perception of our body proportions. In contrast to this intuition, recent research has shown large, striking distortions in people's perceptions of the relative proportions of their own bodies. Specifically, individuals show large distortions when estimating the length of their body parts with a corporal metric, such as the hand, but not with a non-corporal object of the same length (Linkenauger et al., 2015). However, it remains unclear whether these distortions are specific to the perception of the relative proportions of one's own body or whether they generalize to the perception of the relative proportions of all human bodies. To assess this, individuals judged the relative lengths of either their own body parts or the body parts of another individual. We found that people have distorted perceptions of relative body proportions even when viewing the bodies of others. These distortions were greater when estimating the relative body parts of someone of the same gender. These results suggest our implicit full body representation is distorted and influences our perceptions of other people's bodies, especially if the other person's body is similar to our own. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. A principal component analysis of the relationship between the external body shape and internal skeleton for the upper body.

    PubMed

    Nerot, A; Skalli, W; Wang, X

    2016-10-03

    Recent progress in 3D scanning technologies allows easy access to 3D human body envelope. To create personalized human models with an articulated linkage for realistic re-posturing and motion analyses, an accurate estimation of internal skeleton points, including joint centers, from the external envelope is required. For this research project, 3D reconstructions of both internal skeleton and external envelope from low dose biplanar X-rays of 40 male adults were obtained. Using principal component analysis technique (PCA), a low-dimensional dataset was used to predict internal points of the upper body from the trunk envelope. A least squares method was used to find PC scores that fit the PCA-based model to the envelope of a new subject. To validate the proposed approach, estimated internal points were evaluated using a leave-one-out (LOO) procedure, i.e. successively considering each individual from our dataset as an extra-subject. In addition, different methods were proposed to reduce the variability in data and improve the performance of the PCA-based prediction. The best method was considered as the one providing the smallest errors between estimated and reference internal points with an average error of 8.3mm anterior-posteriorly, 6.7mm laterally and 6.5mm vertically. As the proposed approach relies on few or no bony landmarks, it could be easily applicable and generalizable to surface scans from any devices. Combined with automatic body scanning techniques, this study could potentially constitute a new step towards automatic generation of external/internal subject-specific manikins. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Genetic variance estimation with imputed variants finds negligible missing heritability for human height and body mass index.

    PubMed

    Yang, Jian; Bakshi, Andrew; Zhu, Zhihong; Hemani, Gibran; Vinkhuyzen, Anna A E; Lee, Sang Hong; Robinson, Matthew R; Perry, John R B; Nolte, Ilja M; van Vliet-Ostaptchouk, Jana V; Snieder, Harold; Esko, Tonu; Milani, Lili; Mägi, Reedik; Metspalu, Andres; Hamsten, Anders; Magnusson, Patrik K E; Pedersen, Nancy L; Ingelsson, Erik; Soranzo, Nicole; Keller, Matthew C; Wray, Naomi R; Goddard, Michael E; Visscher, Peter M

    2015-10-01

    We propose a method (GREML-LDMS) to estimate heritability for human complex traits in unrelated individuals using whole-genome sequencing data. We demonstrate using simulations based on whole-genome sequencing data that ∼97% and ∼68% of variation at common and rare variants, respectively, can be captured by imputation. Using the GREML-LDMS method, we estimate from 44,126 unrelated individuals that all ∼17 million imputed variants explain 56% (standard error (s.e.) = 2.3%) of variance for height and 27% (s.e. = 2.5%) of variance for body mass index (BMI), and we find evidence that height- and BMI-associated variants have been under natural selection. Considering the imperfect tagging of imputation and potential overestimation of heritability from previous family-based studies, heritability is likely to be 60-70% for height and 30-40% for BMI. Therefore, the missing heritability is small for both traits. For further discovery of genes associated with complex traits, a study design with SNP arrays followed by imputation is more cost-effective than whole-genome sequencing at current prices.

  8. Command Recognition of Robot with Low Dimension Whole-Body Haptic Sensor

    NASA Astrophysics Data System (ADS)

    Ito, Tatsuya; Tsuji, Toshiaki

    The authors have developed “haptic armor”, a whole-body haptic sensor that has an ability to estimate contact position. Although it is developed for safety assurance of robots in human environment, it can also be used as an interface. This paper proposes a command recognition method based on finger trace information. This paper also discusses some technical issues for improving recognition accuracy of this system.

  9. Inland and coastal waters

    NASA Astrophysics Data System (ADS)

    Mouw, Colleen; Greb, Steven

    2012-09-01

    Workshop for Remote Sensing of Coastal and Inland Waters;Madison, Wisconsin, 20-22 June 2012 Coastal and inland water bodies, which have great value for recreation, food supply, commerce, transportation, and human health, have been experiencing external pressure from direct human activities and climate change. Given their societal and economic value, understanding issues of water quality, water quantity, and the impact of environmental change on the ecological and biogeochemical functioning of these water bodies is of interest to a broad range of communities. Remote sensing offers one of the most spatially and temporally comprehensive tools for observing these waters. While there has been some success with remotely observing these water bodies, many challenges still remain, including algorithm performance, atmospheric correction, the relationships between optical properties and biogeochemical parameters, sufficient spatial and spectral resolution, and a lack of uncertainty estimates over the wide range of environmental conditions encountered across these coastal and inland water bodies.

  10. Dynamic Propagation Channel Characterization and Modeling for Human Body Communication

    PubMed Central

    Nie, Zedong; Ma, Jingjing; Li, Zhicheng; Chen, Hong; Wang, Lei

    2012-01-01

    This paper presents the first characterization and modeling of dynamic propagation channels for human body communication (HBC). In-situ experiments were performed using customized transceivers in an anechoic chamber. Three HBC propagation channels, i.e., from right leg to left leg, from right hand to left hand and from right hand to left leg, were investigated under thirty-three motion scenarios. Snapshots of data (2,800,000) were acquired from five volunteers. Various path gains caused by different locations and movements were quantified and the statistical distributions were estimated. In general, for a given reference threshold è = −10 dB, the maximum average level crossing rate of the HBC was approximately 1.99 Hz, the maximum average fade time was 59.4 ms, and the percentage of bad channel duration time was less than 4.16%. The HBC exhibited a fade depth of −4 dB at 90% complementary cumulative probability. The statistical parameters were observed to be centered for each propagation channel. Subsequently a Fritchman model was implemented to estimate the burst characteristics of the on-body fading. It was concluded that the HBC is motion-insensitive, which is sufficient for reliable communication link during motions, and therefore it has great potential for body sensor/area networks. PMID:23250278

  11. Dynamic propagation channel characterization and modeling for human body communication.

    PubMed

    Nie, Zedong; Ma, Jingjing; Li, Zhicheng; Chen, Hong; Wang, Lei

    2012-12-18

    This paper presents the first characterization and modeling of dynamic propagation channels for human body communication (HBC). In-situ experiments were performed using customized transceivers in an anechoic chamber. Three HBC propagation channels, i.e., from right leg to left leg, from right hand to left hand and from right hand to left leg, were investigated under thirty-three motion scenarios. Snapshots of data (2,800,000) were acquired from five volunteers. Various path gains caused by different locations and movements were quantified and the statistical distributions were estimated. In general, for a given reference threshold è = -10 dB, the maximum average level crossing rate of the HBC was approximately 1.99 Hz, the maximum average fade time was 59.4 ms, and the percentage of bad channel duration time was less than 4.16%. The HBC exhibited a fade depth of -4 dB at 90% complementary cumulative probability. The statistical parameters were observed to be centered for each propagation channel. Subsequently a Fritchman model was implemented to estimate the burst characteristics of the on-body fading. It was concluded that the HBC is motion-insensitive, which is sufficient for reliable communication link during motions, and therefore it has great potential for body sensor/area networks.

  12. Hybrid Orientation Based Human Limbs Motion Tracking Method

    PubMed Central

    Glonek, Grzegorz; Wojciechowski, Adam

    2017-01-01

    One of the key technologies that lays behind the human–machine interaction and human motion diagnosis is the limbs motion tracking. To make the limbs tracking efficient, it must be able to estimate a precise and unambiguous position of each tracked human joint and resulting body part pose. In recent years, body pose estimation became very popular and broadly available for home users because of easy access to cheap tracking devices. Their robustness can be improved by different tracking modes data fusion. The paper defines the novel approach—orientation based data fusion—instead of dominating in literature position based approach, for two classes of tracking devices: depth sensors (i.e., Microsoft Kinect) and inertial measurement units (IMU). The detailed analysis of their working characteristics allowed to elaborate a new method that let fuse more precisely limbs orientation data from both devices and compensates their imprecisions. The paper presents the series of performed experiments that verified the method’s accuracy. This novel approach allowed to outperform the precision of position-based joints tracking, the methods dominating in the literature, of up to 18%. PMID:29232832

  13. A Rat Body Phantom for Radiation Analysis

    NASA Technical Reports Server (NTRS)

    Qualls, Garry D.; Clowdsley, Martha S.; Slaba, Tony C.; Walker, Steven A.

    2010-01-01

    To reduce the uncertainties associated with estimating the biological effects of ionizing radiation in tissue, researchers rely on laboratory experiments in which mono-energetic, single specie beams are applied to cell cultures, insects, and small animals. To estimate the radiation effects on astronauts in deep space or low Earth orbit, who are exposed to mixed field broad spectrum radiation, these experimental results are extrapolated and combined with other data to produce radiation quality factors, radiation weighting factors, and other risk related quantities for humans. One way to reduce the uncertainty associated with such extrapolations is to utilize analysis tools that are applicable to both laboratory and space environments. The use of physical and computational body phantoms to predict radiation exposure and its effects is well established and a wide range of human and non-human phantoms are in use today. In this paper, a computational rat phantom is presented, as well as a description of the process through which that phantom has been coupled to existing radiation analysis tools. Sample results are presented for two space radiation environments.

  14. Differential Scavenging Among Pig, Rabbit, and Human Subjects.

    PubMed

    Steadman, Dawnie Wolfe; Dautartas, Angela; Kenyhercz, Michael W; Jantz, Lee M; Mundorff, Amy; Vidoli, Giovanna M

    2018-04-12

    Different animal species have been used as proxies for human remains in decomposition studies for decades, although few studies have sought to validate their use in research aimed at estimating the postmortem interval. This study examines 45 pig, rabbit, and human subjects placed in three seasonal trials at the Anthropology Research Facility. In an earlier paper, we found that overall decomposition trends did vary between species that could be due to differential insect and scavenger behavior. This study specifically examines if scavenger behavior differs by carrion species. Daily photographs, game camera photographs, written observations, and Total Body Score (TBS) documented scavenging and decomposition changes. Results show that raccoons were the most commonly observed vertebrate scavenger, that scavenging was most extensive in winter, and that certain human subjects were preferred over other humans and all non-human subjects. Finally, scavenging activity greatly reduces the accuracy of postmortem interval estimates based on TBS. © 2018 American Academy of Forensic Sciences.

  15. Using Estimations of Entropy to Optimize Complex Human Dynamic Networks under Stress

    DTIC Science & Technology

    2013-12-30

    Age Race Weight (lb.) Height (in.) BMI Body Fat % Class Year Rank 4102 M 22 White 137.6 65 22.9 9.4 Senior Cadet Captain 4103 M 20 White 166.2 74 21.9...mission acts as a failed mission and concludes with a “walk of shame ”. Blood samples were taken before CSH1 and after CSH3; saliva samples were taken...individual scenarios, one subject did not have their body fat % recorded, therefore N=15 for individual correlations involving body fat %. Any

  16. Portable two-channel PPG cardiovascular sensor device

    NASA Astrophysics Data System (ADS)

    Spigulis, Janis; Erts, Renars; Ozols, Maris

    2003-10-01

    A portable sensor device for simultaneous detection and processing of skin-remitted optical signals from any two sites of the body has been developed and tested. The photoplethysmography (PPG) principle was applied to follow the dilatation and contraction of skin blood vessels during the cardiac cycle. The newly developed two-channel approach allows to estimate the vascular blood flow resistance by analysis of time shifts between the PPG pulses detected at different body sites. Potential of the sensor device for express-assessment of human cardio-vascular condition and for body fitness tests has been demonstrated.

  17. Accidental neutron dosimetry with human hair

    NASA Astrophysics Data System (ADS)

    Ekendahl, Daniela; Bečková, Věra; Zdychová, Vlasta; Bulánek, Boris; Prouza, Zdeněk; Štefánik, Milan

    2014-11-01

    Human hair contains sulfur, which can be activated by fast neutrons. The 32S(n,p)32P reaction with a threshold of 2.5 MeV was used for fast neutron dose estimation. It is a very important parameter for individual dose reconstruction with regards to the heterogeneity of the neutron transfer to the human body. Samples of human hair were irradiated in a radial channel of a training reactor VR-1. 32P activity in hair was measured both, directly by means of a proportional counter, and as ash dispersed in a liquid scintillator. Based on neutron spectrum estimation, a relationship between the neutron dose and induced activity was derived. The experiment verified the practical feasibility of this dosimetry method in cases of criticality accidents or malevolent acts with nuclear materials.

  18. Gamma-H2AX-based dose estimation for whole and partial body radiation exposure.

    PubMed

    Horn, Simon; Barnard, Stephen; Rothkamm, Kai

    2011-01-01

    Most human exposures to ionising radiation are partial body exposures. However, to date only limited tools are available for rapid and accurate estimation of the dose distribution and the extent of the body spared from the exposure. These parameters are of great importance for emergency triage and clinical management of exposed individuals. Here, measurements of γ-H2AX immunofluorescence by microscopy and flow cytometry were compared as rapid biodosimetric tools for whole and partial body exposures. Ex vivo uniformly X-irradiated blood lymphocytes from one donor were used to generate a universal biexponential calibration function for γ-H2AX foci/intensity yields per unit dose for time points up to 96 hours post exposure. Foci--but not intensity--levels remained significantly above background for 96 hours for doses of 0.5 Gy or more. Foci-based dose estimates for ex vivo X-irradiated blood samples from 13 volunteers were in excellent agreement with the actual dose delivered to the targeted samples. Flow cytometric dose estimates for X-irradiated blood samples from 8 volunteers were in excellent agreement with the actual dose delivered at 1 hour post exposure but less so at 24 hours post exposure. In partial body exposures, simulated by mixing ex vivo irradiated and unirradiated lymphocytes, foci/intensity distributions were significantly over-dispersed compared to uniformly irradiated lymphocytes. For both methods and in all cases the estimated fraction of irradiated lymphocytes and dose to that fraction, calculated using the zero contaminated Poisson test and γ-H2AX calibration function, were in good agreement with the actual mixing ratios and doses delivered to the samples. In conclusion, γ-H2AX analysis of irradiated lymphocytes enables rapid and accurate assessment of whole body doses while dispersion analysis of foci or intensity distributions helps determine partial body doses and the irradiated fraction size in cases of partial body exposures.

  19. Association between body mass index and body fat in 9-11-year-old children from countries spanning a range of human development.

    PubMed

    Katzmarzyk, P T; Barreira, T V; Broyles, S T; Chaput, J-P; Fogelholm, M; Hu, G; Kuriyan, R; Kurpad, A; Lambert, E V; Maher, C; Maia, J; Matsudo, V; Olds, T; Onywera, V; Sarmiento, O L; Standage, M; Tremblay, M S; Tudor-Locke, C; Zhao, P; Church, T S

    2015-12-01

    The purpose was to assess associations between body mass index (BMI) and body fat in a multinational sample of 9-11-year-old children. The sample included 7265 children from countries ranging in human development. Total body fat (TBF) and percentage body fat (PBF) were measured with a Tanita SC-240 scale and BMI z-scores (BMIz) and percentiles were computed using reference data from the World Health Organization and the U.S. Centers for Disease Control and Prevention, respectively. Mean PBF at BMIz values of -1, 0 and +1 were estimated using multilevel models. Correlations between BMI and TBF were >0.90 in all countries, and correlations between BMI and PBF ranged from 0.76 to 0.96. Boys from India had higher PBF than boys from several other countries at all levels of BMIz. Kenyan girls had lower levels of PBF than girls from several other countries at all levels of BMIz. Boys and girls from Colombia had higher values of PBF at BMIz=-1, whereas Colombian boys at BMIz 0 and +1 also had higher values of PBF than boys in other countries. Our results show a consistently high correlation between BMI and adiposity in children from countries representing a wide range of human development.

  20. Biokinetics of 13C in the human body after oral administration of 13C-labeled glucose as an index for the biokinetics of 14C.

    PubMed

    Masuda, Tsuyoshi; Tako, Yasuhiro; Matsushita, Kensaku; Takeda, Hiroshi; Endo, Masahiro; Nakamura, Yuji; Hisamatsu, Shun'ichi

    2016-09-01

    The retention of 13 C in the human body after oral administration of 13 C-labeled glucose was studied in three healthy volunteer subjects to estimate the 50 year cumulative body burden for 13 C as an index of the committed dose of the radioisotope 14 C. After administration of 13 C-labeled glucose, the volunteers ingested controlled diets with a fixed number of calories for 112 d. Samples of breath and urine were collected up to 112 d after administration. Samples of feces were collected up to 14 d after administration. Hair samples were obtained at 119 d after administration and analyzed as a representative index of the rate of excretion of organic 13 C via pathways such as skin cell exfoliation and mucus secretion. All samples were analyzed for 13 C/ 12 C atomic ratio to determine the rate of excretion via each pathway. We then constructed a metabolic model with a total of four pathways (breath, urine, feces, and other) comprising seven compartments. We determined the values of the biokinetic parameters in the model by using the obtained excretion data. From 74% to 94% of the 13 C administered was excreted in breath, whereas  <2% was excreted in urine and feces. In the other pathway, the excretion rate constant in the compartment with the longest residence time stretched to hundreds of days but the rate constant for each subject was not statistically significant (P value  >  0.1). In addition, the dataset for one of the three subjects was markedly different from those of the other two. When we estimated the 50 year cumulative body burden for 13 C by using our model and we included non-statistically significant parameters, a considerable cumulative body burden was found in the compartments excreting to the other pathway. Although our results on the cumulative body burden of 13 C from orally administered carbon as glucose were inconclusive, we found that the compartments excreting to the other pathway had a markedly long residence time and therefore should be studied further to clarify the fate of carbon in the human body. In addition to excreta, data for serum and blood cell samples were also collected from the subjects to examine the metabolism of 13 C in human body.

  1. Uncertainty of GHz-band Whole-body Average SARs in Infants based on their Kaup Indices

    NASA Astrophysics Data System (ADS)

    Miwa, Hironobu; Hirata, Akimasa; Fujiwara, Osamu; Nagaoka, Tomoaki; Watanabe, Soichi

    We previously showed that a strong correlation exists between the absorption cross section and the body surface area of a human for 0.3-2GHz far field exposure, and proposed a formula for estimating whole-body-average specific absorption rates (WBA-SARs) in terms of height and weight. In this study, to evaluate variability in the WBA-SARs in infants based on their physique, we derived a new formula including Kaup indices of infants, which are being used to check their growth, and thereby estimated the WBA-SARs in infants with respect to their age from 0 month to three years. As a result, we found that under the same height/weight, the smaller the Kaup indices are, the larger the WBA-SARs become, and that the variability in the WBA-SARs is around 15% at the same age. To validate these findings, using the FDTD method, we simulated the GHz-band WBA-SARs in numerical human models corresponding to infants with age of 0, 1, 3, 6 and 9 months, which were obtained by scaling down the anatomically based Japanese three-year child model developed by NICT (National Institute of Information and Communications Technology). Results show that the FDTD-simulated WBA-SARs are smaller by 20% compared to those estimated for infants having the median height and the Kaup index of 0.5 percentiles, which provide conservative WBA-SARs.

  2. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...

  3. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...

  4. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...

  5. Bison body size and climate change.

    PubMed

    Martin, Jeff M; Mead, Jim I; Barboza, Perry S

    2018-05-01

    The relationship between body size and temperature of mammals is poorly resolved, especially for large keystone species such as bison ( Bison bison ). Bison are well represented in the fossil record across North America, which provides an opportunity to relate body size to climate within a species. We measured the length of a leg bone (calcaneal tuber, DstL) in 849 specimens from 60 localities that were dated by stratigraphy and 14 C decay. We estimated body mass ( M ) as M  = (DstL/11.49) 3 . Average annual temperature was estimated from δ 18 O values in the ice cores from Greenland. Calcaneal tuber length of  Bison  declined over the last 40,000 years, that is, average body mass was 37% larger (910 ± 50 kg) than today (665 ± 21 kg). Average annual temperature has warmed by 6°C since the Last Glacial Maximum (~24-18 kya) and is predicted to further increase by 4°C by the end of the 21st century. If body size continues to linearly respond to global temperature, Bison body mass will likely decline by an additional 46%, to 357 ± 54 kg, with an increase of 4°C globally. The rate of mass loss is 41 ± 10 kg per°C increase in global temperature. Changes in body size of Bison may be a result of migration, disease, or human harvest but those effects are likely to be local and short-term and not likely to persist over the long time scale of the fossil record. The strong correspondence between body size of bison and air temperature is more likely the result of persistent effects on the ability to grow and the consequences of sustaining a large body mass in a warming environment. Continuing rises in global temperature will likely depress body sizes of bison, and perhaps other large grazers, without human intervention.

  6. Estimation of metabolic energy expenditure from core temperature using a human thermoregulatory model.

    PubMed

    Welles, Alexander P; Buller, Mark J; Looney, David P; Rumpler, William V; Gribok, Andrei V; Hoyt, Reed W

    2018-02-01

    Human metabolic energy expenditure is critical to many scientific disciplines but can only be measured using expensive and/or restrictive equipment. The aim of this work is to determine whether the SCENARIO thermoregulatory model can be adapted to estimate metabolic rate (M) from core body temperature (T C ). To validate this method of M estimation, data were collected from fifteen test volunteers (age = 23 ± 3yr, height = 1.73 ± 0.07m, mass = 68.6 ± 8.7kg, body fat = 16.7 ± 7.3%; mean ± SD) who wore long sleeved nylon jackets and pants (I tot,clo = 1.22, I m = 0.41) during treadmill exercise tasks (32 trials; 7.8 ± 0.5km in 1h; air temp. = 22°C, 50% RH, wind speed = 0.35ms -1 ). Core body temperatures were recorded by ingested thermometer pill and M data were measured via whole room indirect calorimetry. Metabolic rate was estimated for 5min epochs in a two-step process. First, for a given epoch, a range of M values were input to the SCENARIO model and a corresponding range of T C values were output. Second, the output T C range value with the lowest absolute error relative to the observed T C for the given epoch was identified and its corresponding M range input was selected as the estimated M for that epoch. This process was then repeated for each subsequent remaining epoch. Root mean square error (RMSE), mean absolute error (MAE), and bias between observed and estimated M were 186W, 130 ± 174W, and 33 ± 183W, respectively. The RMSE for total energy expenditure by exercise period was 0.30 MJ. These results indicate that the SCENARIO model is useful for estimating M from T C when measurement is otherwise impractical. Published by Elsevier Ltd.

  7. Estimating DXA total body fat percentage by lipometer subcutaneous adipose tissue thicknesses.

    PubMed

    Tafeit, Erwin; Greilberger, Joachim; Cvirn, Gerhard; Lipp, Rainer Walther; Schnedl, Wolfgang Johann; Jürimäe, Toivo; Jürimäe, Jaak; Wallner-Liebmann, Sandra Johanna

    2009-06-01

    DXA is an accepted reference method to estimate body composition. However several difficulties in the applicability exist. The equipment is rather expensive, not portable, impractical for measurement of big study populations and it provides a minimal amount of ionizing radiation exposure. The optical device Lipometer (EU Pat.No. 0516251) provides non-invasive, quick, precise and safe measurements of subcutaneous adipose tissue (SAT) layer thicknesses at any site of the human body. Compared to DXA there are some advantages in the Lipometer approach, because this device is portable, quick, not expensive and no radiation is involved. To use these advantages in the field of total body fat% (TBF%) assessment, an acceptable estimation of DXA TBF% by Lipometer SAT thicknesses is necessary, which was the aim of this study. Height, weight, waist and hip circumferences, DXA TBF% and Lipometer SAT thicknesses at fifteen defined body sites were measured in 28 healthy men (age: 33.9 +/- 16.6 years) and 52 healthy women (age: 40.1 +/- 10.7 years). To estimate Lipometer TBF% stepwise multiple regression analysis was applied, using DXA TBF% as dependent variable. Using the fifteen Lipometer SAT thicknesses together with age, height, weight and BMI as independent variables provided the best estimations of Lipometer TBF% for both genders with strong correlations to DXA TBF% (R = 0.985 for males and R = 0.953 for females). The limits of agreement were -2.48% to +2.48% for males and -4.28% to + 4.28% for females. For both genders we received a bias of 0.00%. The results of this paper extend the abilities of the Lipometer by a precise estimation of TBF% using DXA as golden standard.

  8. Factors Associated With Changes in Body Composition Shortly After Orthotopic Liver Transplantation: The Potential Influence of Immunosuppressive Agents.

    PubMed

    Brito-Costa, Ana; Pereira-da-Silva, Luís; Papoila, Ana Luísa; Alves, Marta; Mateus, Élia; Nolasco, Fernando; Barroso, Eduardo

    2016-08-01

    This study aimed to determine factors associated with body composition changes shortly after liver transplantation (LTx), including the influence of immunosuppressive agents. The combined resting energy expenditure (REE) and handgrip strength provided a valuable assessment in data interpretation of body composition. This observational single-center study included a cohort of consecutive end-stage liver disease patients with indications for LTx over 2 years. Cyclosporine was preferred for diabetic, hepatitis C-infected, and human immunodeficiency virus-infected patients per the transplant center protocol. Subjective Global Assessment, handgrip strength, multifrequency bioelectrical impedance analysis, and REE measurements were collected. The assessments were performed before LTx (T0) and at medians of 9 (T1) and 36 (T2) days after LTx. The fat mass index (FMI) and lean mass index (LMI) were surrogates of adiposity and skeletal muscle, respectively. Multiple linear regression analysis was used. Fifty-six patients with a mean age of 53.7 (8.5) years were included; 87.5% were men. Preoperative Subjective Global Assessment undernourishment (β-estimate = 17.9; P = 0.004) and of drug addiction absence (β estimate = 14.6; P = 0.049) were associated with FMI increase. Higher REE at T1 (per 100 kcal) was associated with LMI increase (β estimate = 1.70; P = 0.012) and body cell mass increase (β estimate = 1.60; P = 0.049). The cyclosporine-based regimen was associated with FMI decrease (β estimate = -25.64; P < 0.001) and LMI increase (β estimate = 23.76; P < 0.001) when compared with a tacrolimus-based regimen. Steroids did not affect body composition. The cyclosporine-based regimen was independently associated with decreased adiposity and increased skeletal muscle compared with the tacrolimus-based regimen. Future randomized controlled trials are needed to confirm these findings.

  9. Analyses of the Microbial Diversity across the Human Microbiome

    PubMed Central

    Li, Kelvin; Bihan, Monika; Yooseph, Shibu; Methé, Barbara A.

    2012-01-01

    Analysis of human body microbial diversity is fundamental to understanding community structure, biology and ecology. The National Institutes of Health Human Microbiome Project (HMP) has provided an unprecedented opportunity to examine microbial diversity within and across body habitats and individuals through pyrosequencing-based profiling of 16 S rRNA gene sequences (16 S) from habits of the oral, skin, distal gut, and vaginal body regions from over 200 healthy individuals enabling the application of statistical techniques. In this study, two approaches were applied to elucidate the nature and extent of human microbiome diversity. First, bootstrap and parametric curve fitting techniques were evaluated to estimate the maximum number of unique taxa, Smax, and taxa discovery rate for habitats across individuals. Next, our results demonstrated that the variation of diversity within low abundant taxa across habitats and individuals was not sufficiently quantified with standard ecological diversity indices. This impact from low abundant taxa motivated us to introduce a novel rank-based diversity measure, the Tail statistic, (“τ”), based on the standard deviation of the rank abundance curve if made symmetric by reflection around the most abundant taxon. Due to τ’s greater sensitivity to low abundant taxa, its application to diversity estimation of taxonomic units using taxonomic dependent and independent methods revealed a greater range of values recovered between individuals versus body habitats, and different patterns of diversity within habitats. The greatest range of τ values within and across individuals was found in stool, which also exhibited the most undiscovered taxa. Oral and skin habitats revealed variable diversity patterns, while vaginal habitats were consistently the least diverse. Collectively, these results demonstrate the importance, and motivate the introduction, of several visualization and analysis methods tuned specifically for next-generation sequence data, further revealing that low abundant taxa serve as an important reservoir of genetic diversity in the human microbiome. PMID:22719823

  10. Diet and body fat in adolescence and early adulthood: a systematic review of longitudinal studies.

    PubMed

    Schneider, Bruna Celestino; Dumith, Samuel Carvalho; Orlandi, Silvana Paiva; Assunção, Maria Cecília Formoso

    2017-05-01

    Adipose tissue is a vital component of the human body, but in excess, it represents a risk to health. According to the World Health Organization, one of the main factors determining excessive body adiposity is the dietary habit. This systematic review investigated longitudinal studies that assessed the association between diet and body fat in adolescents and young adults. Twenty-one relevant papers published between 2001 and 2015 were selected. The most used method for estimating body fat was the body mass index (15 studies). Diet was most commonly assessed by estimating the consumption of food groups (cereals, milk and dairy products) and specific foods (sugar-sweetened beverages, soft drinks, fast foods, milk, etc.). Ten studies found a direct association between diet and quantity of body fat. During adolescence, adhering to a dietary pattern characterized by high consumption of energy-dense food, fast foods, sugar-sweetened beverages and soft drinks, as well as low fiber intake, appears to contribute to an increase in body fat in early adulthood. The findings of the present study suggest that the frequent consumption of unhealthy foods and food groups (higher energy density and lower nutrient content) in adolescence is associated with higher quantity of body fat in early adulthood.

  11. In vitro assay to estimate tea astringency via observing flotation of artificial oil bodies sheltered by caleosin fused with histatin 3.

    PubMed

    Shih, Yu-En; Lin, Yu-Chih; Chung, Tse-Yu; Liu, Mei-Chun; Chen, Guan-Heng; Wu, Chia-Chang; Tzen, Jason T C

    2017-10-01

    Astringency, a sensory characteristic of food and beverages rich in polyphenols, mainly results from the formation of complexes between polyphenols and salivary proteins, causing a reduction of the lubricating properties of saliva. To develop an in vitro assay to estimate the astringency of oolong tea infusion, artificial oil bodies were constituted with sesame oil sheltered by a modified caleosin fused with histatin 3, one of the human salivary small peptides. Aggregation of artificial oil bodies was induced when they were mixed with oolong tea infusion or its major polyphenolic compound, (-)-epigallocatechin gallate (EGCG) of 100μM as observed in light microscopy. The aggregated artificial oil bodies gradually floated on top of the solution and formed a visible milky layer whose thickness was in proportion to the concentrations of tea infusion. This assay system was applied to test four different oolong tea infusions with sensory astringency corresponding to their EGCG contents. The result showed that relative astringency of the four tea infusions was correlated to the thickness of floated artificial oil bodies, and could be estimated according to the standard curve generated by simultaneously observing a serial dilution of the tea infusion with the highest astringency. Copyright © 2016. Published by Elsevier B.V.

  12. Solar particle event organ doses and dose equivalents for interplanetary crews: variations due to body size

    NASA Technical Reports Server (NTRS)

    Zapp, E. N.; Townsend, L. W.; Cucinotta, F. A.

    2002-01-01

    Proper assessments of spacecraft shielding requirements and concomitant estimates of risk to critical body organs of spacecraft crews from energetic space radiation require accurate, quantitative methods of characterizing the compositional changes in these radiation fields as they pass through the spacecraft and overlying tissue. When estimating astronaut radiation organ doses and dose equivalents it is customary to use the Computerized Anatomical Man (CAM) model of human geometry to account for body self-shielding. Usually, the distribution for the 50th percentile man (175 cm height; 70 kg mass) is used. Most male members of the U.S. astronaut corps are taller and nearly all have heights that deviate from the 175 cm mean. In this work, estimates of critical organ doses and dose equivalents for interplanetary crews exposed to an event similar to the October 1989 solar particle event are presented for male body sizes that vary from the 5th to the 95th percentiles. Overall the results suggest that calculations of organ dose and dose equivalent may vary by as much as approximately 15% as body size is varied from the 5th to the 95th percentile in the population used to derive the CAM model data. c2002 Published by Elsevier Science Ltd on behalf of COSPAR.

  13. Scoring of Decomposition: A Proposed Amendment to the Method When Using a Pig Model for Human Studies.

    PubMed

    Keough, Natalie; Myburgh, Jolandie; Steyn, Maryna

    2017-07-01

    Decomposition studies often use pigs as proxies for human cadavers. However, differences in decomposition sequences/rates relative to humans have not been scientifically examined. Descriptions of five main decomposition stages (humans) were developed and refined by Galloway and later by Megyesi. However, whether these changes/processes are alike in pigs is unclear. Any differences can have significant effects when pig models are used for human PMI estimation. This study compared human decomposition models to the changes observed in pigs. Twenty pigs (50-90 kg) were decomposed over five months and decompositional features recorded. Total body scores (TBS) were calculated. Significant differences were observed during early decomposition between pigs and humans. An amended scoring system to be used in future studies was developed. Standards for PMI estimation derived from porcine models may not directly apply to humans and may need adjustment. Porcine models, however, remain valuable to study variables influencing decomposition. © 2016 American Academy of Forensic Sciences.

  14. Neandertal clavicle length

    PubMed Central

    Trinkaus, Erik; Holliday, Trenton W.; Auerbach, Benjamin M.

    2014-01-01

    The Late Pleistocene archaic humans from western Eurasia (the Neandertals) have been described for a century as exhibiting absolutely and relatively long clavicles. This aspect of their body proportions has been used to distinguish them from modern humans, invoked to account for other aspects of their anatomy and genetics, used in assessments of their phylogenetic polarities, and used as evidence for Late Pleistocene population relationships. However, it has been unclear whether the usual scaling of Neandertal clavicular lengths to their associated humeral lengths reflects long clavicles, short humeri, or both. Neandertal clavicle lengths, along with those of early modern humans and latitudinally diverse recent humans, were compared with both humeral lengths and estimated body masses (based on femoral head diameters). The Neandertal do have long clavicles relative their humeri, even though they fall within the ranges of variation of early and recent humans. However, when scaled to body masses, their humeral lengths are relatively short, and their clavicular lengths are indistinguishable from those of Late Pleistocene and recent modern humans. The few sufficiently complete Early Pleistocene Homo clavicles seem to have relative lengths also well within recent human variation. Therefore, appropriately scaled clavicular length seems to have varied little through the genus Homo, and it should not be used to account for other aspects of Neandertal biology or their phylogenetic status. PMID:24616525

  15. Air displacement plethysmography: validation in overweight and obese subjects.

    PubMed

    Ginde, Samir R; Geliebter, Allan; Rubiano, Frederick; Silva, Analiza M; Wang, Jack; Heshka, Stanley; Heymsfield, Steven B

    2005-07-01

    Patients with moderate and severe obesity, because of their physical size, often cannot be evaluated with conventional body composition measurement systems. The BOD POD air displacement plethysmography (ADP) system can accommodate a large body volume and may provide an opportunity for measuring body density (D(b)) in obese subjects. D(b) can be used in two- or three-compartment body composition models for estimating total body fat in patients with severe obesity. The purpose of this study was to compare D(b) measured by ADP to D(b) measured by underwater weighing (UWW) in subjects ranging from normal weight to severely obese. D(b) was measured with UWW and BOD POD in 123 subjects (89 men and 34 women; age, 46.5 +/- 16.9 years; BMI, 31.5 +/- 7.3 kg/m2); 15, 70, and 10 subjects were overweight (25 < or = BMI < 30 kg/m2), obese (30 < or = BMI < 40 kg/m2), and severely obese (BMI > or = 40 kg/m2), respectively. There was a strong correlation between D(b) (kilograms per liter) measured by UWW and ADP (r = 0.94, standard error of the estimate = 0.0073 kg/L, p < 0.001). Similarly, percent fat estimates from UWW and ADP using the two-compartment Siri equation were highly correlated (r = 0.94, standard error of the estimate = 3.58%, p < 0.001). Bland-Altman analysis showed no significant bias between D(b) measured by UWW and ADP. After controlling for D(b) measured by ADP, no additional between-subject variation in D(b) by UWW was accounted for by subject age, sex, or BMI. Body density, an important physical property used in human body composition models, can be accurately measured by ADP in overweight and obese subjects.

  16. Propulsive efficiency of the underwater dolphin kick in humans.

    PubMed

    von Loebbecke, Alfred; Mittal, Rajat; Fish, Frank; Mark, Russell

    2009-05-01

    Three-dimensional fully unsteady computational fluid dynamic simulations of five Olympic-level swimmers performing the underwater dolphin kick are used to estimate the swimmer's propulsive efficiencies. These estimates are compared with those of a cetacean performing the dolphin kick. The geometries of the swimmers and the cetacean are based on laser and CT scans, respectively, and the stroke kinematics is based on underwater video footage. The simulations indicate that the propulsive efficiency for human swimmers varies over a relatively wide range from about 11% to 29%. The efficiency of the cetacean is found to be about 56%, which is significantly higher than the human swimmers. The computed efficiency is found not to correlate with either the slender body theory or with the Strouhal number.

  17. A research on the postural stability of a person wearing the lower limb exoskeletal robot by the HAT model.

    PubMed

    Chang, Minsu; Kim, Yeongmin; Lee, Yoseph; Jeon, Doyoung

    2017-07-01

    This paper proposes a method of detecting the postural stability of a person wearing the lower limb exoskeletal robot with the HAT(Head-Arm-Trunk) model. Previous studies have shown that the human posture is stable when the CoM(Center of Mass) of the human body is placed on the BoS(Base of Support). In the case of the lower limb exoskeletal robot, the motion data, which are used for the CoM estimation, are acquired by sensors in the robot. The upper body, however, does not have sensors in each segment so that it may cause the error of the CoM estimation. In this paper, the HAT(Head-Arm-Trunk) model which combines head, arms, and torso into a single segment is considered because the motion of head and arms are unknown due to the lack of sensors. To verify the feasibility of HAT model, the reflecting markers are attached to each segment of the whole human body and the exact motion data are acquired by the VICON to compare the COM of the full body model and HAT model. The difference between the CoM with full body and that with HAT model is within 20mm for the various motions of head and arms. Based on the HAT model, the XCoM(Extrapolated Center of Mass) which includes the velocity of the CoM is used for prediction of the postural stability. The experiment of making unstable posture shows that the XCoM of the whole body based on the HAT model is feasible to detect the instance of postural instability earlier than the CoM by 20-250 msec. This result may be used for the lower limb exoskeletal robot to prepare for any action to prevent the falling down.

  18. The Influence of Segmental Impedance Analysis in Predicting Validity of Consumer Grade Bioelectrical Impedance Analysis Devices

    NASA Astrophysics Data System (ADS)

    Sharp, Andy; Heath, Jennifer; Peterson, Janet

    2008-05-01

    Consumer grade bioelectric impedance analysis (BIA) instruments measure the body's impedance at 50 kHz, and yield a quick estimate of percent body fat. The frequency dependence of the impedance gives more information about the current pathway and the response of different tissues. This study explores the impedance response of human tissue at a range of frequencies from 0.2 - 102 kHz using a four probe method and probe locations standard for segmental BIA research of the arm. The data at 50 kHz, for a 21 year old healthy Caucasian male (resistance of 180φ±10 and reactance of 33φ±2) is in agreement with previously reported values [1]. The frequency dependence is not consistent with simple circuit models commonly used in evaluating BIA data, and repeatability of measurements is problematic. This research will contribute to a better understanding of the inherent difficulties in estimating body fat using consumer grade BIA devices. [1] Chumlea, William C., Richard N. Baumgartner, and Alex F. Roche. ``Specific resistivity used to estimate fat-free mass from segmental body measures of bioelectrical impedance.'' Am J Clin Nutr 48 (1998): 7-15.

  19. A Framework for Analyzing the Whole Body Surface Area from a Single View

    PubMed Central

    Doretto, Gianfranco; Adjeroh, Donald

    2017-01-01

    We present a virtual reality (VR) framework for the analysis of whole human body surface area. Usual methods for determining the whole body surface area (WBSA) are based on well known formulae, characterized by large errors when the subject is obese, or belongs to certain subgroups. For these situations, we believe that a computer vision approach can overcome these problems and provide a better estimate of this important body indicator. Unfortunately, using machine learning techniques to design a computer vision system able to provide a new body indicator that goes beyond the use of only body weight and height, entails a long and expensive data acquisition process. A more viable solution is to use a dataset composed of virtual subjects. Generating a virtual dataset allowed us to build a population with different characteristics (obese, underweight, age, gender). However, synthetic data might differ from a real scenario, typical of the physician’s clinic. For this reason we develop a new virtual environment to facilitate the analysis of human subjects in 3D. This framework can simulate the acquisition process of a real camera, making it easy to analyze and to create training data for machine learning algorithms. With this virtual environment, we can easily simulate the real setup of a clinic, where a subject is standing in front of a camera, or may assume a different pose with respect to the camera. We use this newly designated environment to analyze the whole body surface area (WBSA). In particular, we show that we can obtain accurate WBSA estimations with just one view, virtually enabling the possibility to use inexpensive depth sensors (e.g., the Kinect) for large scale quantification of the WBSA from a single view 3D map. PMID:28045895

  20. Estimation and harvesting of human heat power for wearable electronic devices

    NASA Astrophysics Data System (ADS)

    Dziurdzia, P.; Brzozowski, I.; Bratek, P.; Gelmuda, W.; Kos, A.

    2016-01-01

    The paper deals with the issue of self-powered wearable electronic devices that are capable of harvesting free available energy dissipated by the user in the form of human heat. The free energy source is intended to be used as a secondary power source supporting primary battery in a sensor bracelet. The main scope of the article is a presentation of the concept for a measuring setup used to quantitative estimation of heat power sources in different locations over the human body area. The crucial role in the measurements of the human heat plays a thermoelectric module working in the open circuit mode. The results obtained during practical tests are confronted with the requirements of the dedicated thermoelectric generator. A prototype design of a human warmth energy harvester with an ultra-low power DC-DC converter based on the LTC3108 circuit is analysed.

  1. Differential Decomposition Among Pig, Rabbit, and Human Remains.

    PubMed

    Dautartas, Angela; Kenyhercz, Michael W; Vidoli, Giovanna M; Meadows Jantz, Lee; Mundorff, Amy; Steadman, Dawnie Wolfe

    2018-03-30

    While nonhuman animal remains are often utilized in forensic research to develop methods to estimate the postmortem interval, systematic studies that directly validate animals as proxies for human decomposition are lacking. The current project compared decomposition rates among pigs, rabbits, and humans at the University of Tennessee's Anthropology Research Facility across three seasonal trials that spanned nearly 2 years. The Total Body Score (TBS) method was applied to quantify decomposition changes and calculate the postmortem interval (PMI) in accumulated degree days (ADD). Decomposition trajectories were analyzed by comparing the estimated and actual ADD for each seasonal trial and by fuzzy cluster analysis. The cluster analysis demonstrated that the rabbits formed one group while pigs and humans, although more similar to each other than either to rabbits, still showed important differences in decomposition patterns. The decomposition trends show that neither nonhuman model captured the pattern, rate, and variability of human decomposition. © 2018 American Academy of Forensic Sciences.

  2. Genome-wide genetic homogeneity between sexes and populations for human height and body mass index.

    PubMed

    Yang, Jian; Bakshi, Andrew; Zhu, Zhihong; Hemani, Gibran; Vinkhuyzen, Anna A E; Nolte, Ilja M; van Vliet-Ostaptchouk, Jana V; Snieder, Harold; Esko, Tonu; Milani, Lili; Mägi, Reedik; Metspalu, Andres; Hamsten, Anders; Magnusson, Patrik K E; Pedersen, Nancy L; Ingelsson, Erik; Visscher, Peter M

    2015-12-20

    Sex-specific genetic effects have been proposed to be an important source of variation for human complex traits. Here we use two distinct genome-wide methods to estimate the autosomal genetic correlation (rg) between men and women for human height and body mass index (BMI), using individual-level (n = ∼44 000) and summary-level (n = ∼133 000) data from genome-wide association studies. Results are consistent and show that the between-sex genetic correlation is not significantly different from unity for both traits. In contrast, we find evidence of genetic heterogeneity between sexes for waist-hip ratio (rg = ∼0.7) and between populations for BMI (rg = ∼0.9 between Europe and the USA) but not for height. The lack of evidence for substantial genetic heterogeneity for body size is consistent with empirical findings across traits and species. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. A kinematic model to estimate effective dose of radioactive substances in a human body

    NASA Astrophysics Data System (ADS)

    Sasaki, S.; Yamada, T.

    2013-05-01

    The great earthquake occurred in the north-east area in Japan in March 11, 2011. Facility system to control Fukushima Daiichi nuclear power station was completely destroyed by the following giant tsunami. From the damaged reactor containment vessels, an amount of radioactive substances had leaked and diffused in the vicinity of this station. Radiological internal exposure became a serious social issue both in Japan and all over the world. The present study provides an easily understandable, kinematic-based model to estimate the effective dose of radioactive substances in a human body by simplifying the complicated mechanism of metabolism. International Commission on Radiological Protection (ICRP) has developed a sophisticated model, which is well-known as a standard method to calculate the effective dose for radiological protection. However, owing to that ICRP method is fine, it is rather difficult for non-professional people of radiology to gasp the whole images of the movement and the influences of radioactive substances in a human body. Therefore, in the present paper we propose a newly-derived and easily-understandable model to estimate the effective dose. The present method is very similar with the traditional and conventional tank model in hydrology. Ingestion flux of radioactive substances corresponds to rain intensity and the storage of radioactive substances to the water storage in a basin in runoff analysis. The key of the present method is to estimate the energy radiated in the radioactive nuclear disintegration of an atom by using classical theory of β decay and special relativity for various kinds of radioactive atoms. The parameters used in this model are only physical half-time and biological half-time, and there are no operational parameters or coefficients to adjust our theoretical runoff to ICRP. Figure shows the time-varying effective dose with ingestion duration, and we can confirm the validity of our model. The time-varying effective dose with ingestion duration

  4. The interaction of natural background gamma radiation with depleted uranium micro-particles in the human body.

    PubMed

    Pattison, John E

    2013-03-01

    In this study, some characteristics of the photo-electrons produced when natural background gamma radiation interacts with micron-sized depleted uranium (DU) particles in the human body have been estimated using Monte Carlo simulations. In addition, an estimate has been made of the likelihood of radiological health effects occurring due to such an exposure. Upon exposure to naturally occurring background gamma radiation, DU particles in the body will produce an enhancement of the dose to the tissue in the immediate vicinity of the particles due to the photo-electric absorption of the radiation in the particle. In this study, the photo-electrons produced by a 10 μm-size particle embedded in tissue at the centre of the human torso have been investigated. The mean energies of the photo-electrons in the DU particle and in the two consecutive immediately surrounding 2 μm-wide tissue shells around the particle were found to be 38, 49 and 50 keV, respectively, with corresponding ranges of 1.3, 38 and 39 μm, respectively. The total photo-electron fluence-rates in the two consecutive 2 μm-wide tissue layers were found to be 14% and 7% of the fluence-rate in the DU particle, respectively. The estimated dose enhancement due to one 10 μm-sized DU particle in 1 cm(3) of tissue was less than 2 in 10 million of the dose received by the tissue without a particle being present. The increase in risk of death from cancer due to this effect is consequently insignificant.

  5. The effect of body postures on the distribution of air gap thickness and contact area.

    PubMed

    Mert, Emel; Psikuta, Agnes; Bueno, Marie-Ange; Rossi, René M

    2017-02-01

    The heat and mass transfer in clothing is predominantly dependent on the thickness of air layer and the magnitude of contact area between the body and the garment. The air gap thickness and magnitude of the contact area can be affected by the posture of the human body. Therefore, in this study, the distribution of the air gap and the contact area were investigated for different body postures of a flexible manikin. In addition, the effect of the garment fit (regular and loose) and style (t-shirts, sweatpants, jacket and trousers) were analysed for the interaction between the body postures and the garment properties. A flexible manikin was scanned using a three-dimensional (3D) body scanning technique, and the scans were post-processed in dedicated software. The body posture had a strong effect on the air gap thickness and the contact area for regions where the garment had a certain distance from the body. Furthermore, a mathematical model was proposed to estimate the possible heat transfer coefficient for the observed air layers and their change with posture. The outcome of this study can be used to improve the design of the protective and functional garments and predict their effect on the human body.

  6. Impact of brown adipose tissue on body fatness and glucose metabolism in healthy humans.

    PubMed

    Matsushita, M; Yoneshiro, T; Aita, S; Kameya, T; Sugie, H; Saito, M

    2014-06-01

    Brown adipose tissue (BAT) is involved in the regulation of whole-body energy expenditure and adiposity. Some clinical studies have reported an association between BAT and blood glucose in humans. To examine the impact of BAT on glucose metabolism, independent of that of body fatness, age and sex in healthy adult humans. Two hundred and sixty healthy volunteers (184 males and 76 females, 20-72 years old) underwent fluorodeoxyglucose-positron emission tomography and computed tomography after 2 h of cold exposure to assess maximal BAT activity. Blood parameters including glucose, HbA1c and low-density lipoprotein (LDL)/high-density lipoprotein-cholesterol were measured by conventional methods, and body fatness was estimated from body mass index (BMI), body fat mass and abdominal fat area. The impact of BAT on body fatness and blood parameters was determined by logistic regression with the use of univariate and multivariate models. Cold-activated BAT was detected in 125 (48%) out of 260 subjects. When compared with subjects without detectable BAT, those with detectable BAT were younger and showed lower adiposity-related parameters such as the BMI, body fat mass and abdominal fat area. Although blood parameters were within the normal range in the two subject groups, HbA1c, total cholesterol and LDL-cholesterol were significantly lower in the BAT-positive group. Blood glucose also tended to be lower in the BAT-positive group. Logistic regression demonstrated that BAT, in addition to age and sex, was independently associated with BMI, body fat mass, and abdominal visceral and subcutaneous fat areas. For blood parameters, multivariate analysis after adjustment for age, sex and body fatness revealed that BAT was a significantly independent determinant of glucose and HbA1c. BAT, independent of age, sex and body fatness, has a significant impact on glucose metabolism in adult healthy humans.

  7. Instrumentation for investigation of the depth-dose distribution by the Liulin-5 instrument of a human phantom on the Russian segment of ISS for estimation of the radiation risk during long term space flights

    NASA Technical Reports Server (NTRS)

    Semkova, J.; Koleva, R.; Todorova, G.; Kanchev, N.; Petrov, V.; Shurshakov, V.; Tchhernykh, I.; Kireeva, S.

    2004-01-01

    Described is the Liulin-5 experiment and instrumentation, developed for investigation of the space radiation doses depth distribution in a human phantom on the Russian Segment of the International Space Station (ISS). Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The experiment MATROSHKA-R is aimed to study the depth dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different places of the Russian Segment of ISS. Energy deposition spectra, linear energy transfer spectra, flux and dose rates for protons and the biologically-relevant heavy ion components of the galactic cosmic radiation will be measured simultaneously with near real time resolution at different depths of the phantom by a telescope of silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, verify the models of radiation environment in low Earth orbit, validate body transport model and correlate organ level dose to skin dose. Presented are the test results of the prototype unit. The spherical phantom will be flown on the ISS in 2004 year and Liulin-5 experiment is planned for 2005 year. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

  8. Estimation of human body concentrations of DDT from indoor residual spraying for malaria control.

    PubMed

    Gyalpo, Tenzing; Fritsche, Lukas; Bouwman, Henk; Bornman, Riana; Scheringer, Martin; Hungerbühler, Konrad

    2012-10-01

    Inhabitants of dwellings treated with DDT for indoor residual spraying show high DDT levels in blood and breast milk. This is of concern since mothers transfer lipid-soluble contaminants such as DDT via breastfeeding to their children. Focusing on DDT use in South Africa, we employ a pharmacokinetic model to estimate DDT levels in human lipid tissue over the lifetime of an individual to determine the amount of DDT transferred to children during breastfeeding, and to identify the dominant DDT uptake routes. In particular, the effects of breastfeeding duration, parity, and mother's age on DDT concentrations of mother and infant are investigated. Model results show that primiparous mothers have greater DDT concentrations than multiparous mothers, which causes higher DDT exposure of first-born children. DDT in the body mainly originates from diet. Generally, our modeled DDT levels reproduce levels found in South African biomonitoring data within a factor of 3. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Visual assessment of the radiation distribution in the ISS Lab module: visualization in the human body

    NASA Technical Reports Server (NTRS)

    Saganti, P. B.; Zapp, E. N.; Wilson, J. W.; Cucinotta, F. A.

    2001-01-01

    The US Lab module of the International Space Station (ISS) is a primary working area where the crewmembers are expected to spend majority of their time. Because of the directionality of radiation fields caused by the Earth shadow, trapped radiation pitch angle distribution, and inherent variations in the ISS shielding, a model is needed to account for these local variations in the radiation distribution. We present the calculated radiation dose (rem/yr) values for over 3,000 different points in the working area of the Lab module and estimated radiation dose values for over 25,000 different points in the human body for a given ambient radiation environment. These estimated radiation dose values are presented in a three dimensional animated interactive visualization format. Such interactive animated visualization of the radiation distribution can be generated in near real-time to track changes in the radiation environment during the orbit precession of the ISS.

  10. Different Cortical Dynamics in Face and Body Perception: An MEG study

    PubMed Central

    Meeren, Hanneke K. M.; de Gelder, Beatrice; Ahlfors, Seppo P.; Hämäläinen, Matti S.; Hadjikhani, Nouchine

    2013-01-01

    Evidence from functional neuroimaging indicates that visual perception of human faces and bodies is carried out by distributed networks of face and body-sensitive areas in the occipito-temporal cortex. However, the dynamics of activity in these areas, needed to understand their respective functional roles, are still largely unknown. We monitored brain activity with millisecond time resolution by recording magnetoencephalographic (MEG) responses while participants viewed photographs of faces, bodies, and control stimuli. The cortical activity underlying the evoked responses was estimated with anatomically-constrained noise-normalised minimum-norm estimate and statistically analysed with spatiotemporal cluster analysis. Our findings point to distinct spatiotemporal organization of the neural systems for face and body perception. Face-selective cortical currents were found at early latencies (120–200 ms) in a widespread occipito-temporal network including the ventral temporal cortex (VTC). In contrast, early body-related responses were confined to the lateral occipito-temporal cortex (LOTC). These were followed by strong sustained body-selective responses in the orbitofrontal cortex from 200–700 ms, and in the lateral temporal cortex and VTC after 500 ms latency. Our data suggest that the VTC region has a key role in the early processing of faces, but not of bodies. Instead, the LOTC, which includes the extra-striate body area (EBA), appears the dominant area for early body perception, whereas the VTC contributes to late and post-perceptual processing. PMID:24039712

  11. Use of Iodine-131 to Tellurium-132 Ratios for Assessing the Relationships between Human Inhaled Radioactivity and Environmental Monitoring after the Accident in Fukushima.

    PubMed

    Uchiyama, Koji; Miyashita, Masami; Tanishima, Yoshinobu; Maeda, Shigenobu; Sato, Hitoshi; Yoshikawa, Jun; Watanabe, Shuji; Shibata, Masamichi; Ohhira, Shuji; Kobashi, Gen

    2018-03-09

    Significant differences in findings were seen between the intake amounts of iodine-131 that were derived from direct measurements and the estimated intake from environmental monitoring data at the Fukushima accident. To clarify these discrepancies, we have investigated the iodine-131 and tellurium-132 body burdens of five human subjects, who after being exposed to a radioactive plume, underwent 21.5 h whole body counter measurements at Fukui Prefectural Hospital, so clear intake scenario and thyroid counter measurement data were available. To determine the iodine-131 and tellurium-132 body burdens, we introduced a new method of whole body counter calibration composed of a self-consistent approach with the time-dependent correction efficiency factors concept. The ratios of iodine-131 to tellurium-132, ranging from 0.96 ± 0.05 to 2.29 ± 0.38, were consistent with results of the environmental measurements. The 24 h iodine uptake values ranging from 12.1-16.0% were within euthyroid range in Japanese people. These results suggest, even if the relatively low thyroid iodine uptake in the Japanese population was taken into consideration, that there is no doubt about the consistency between direct measurements and environmental monitoring data. Adequate intake scenario is suggested to be principally important to estimate the inhaled radioactivity in areas in or around nuclear accidents.

  12. Estimating Physical Activity Energy Expenditure with the Kinect Sensor in an Exergaming Environment

    PubMed Central

    Nathan, David; Huynh, Du Q.; Rubenson, Jonas; Rosenberg, Michael

    2015-01-01

    Active video games that require physical exertion during game play have been shown to confer health benefits. Typically, energy expended during game play is measured using devices attached to players, such as accelerometers, or portable gas analyzers. Since 2010, active video gaming technology incorporates marker-less motion capture devices to simulate human movement into game play. Using the Kinect Sensor and Microsoft SDK this research aimed to estimate the mechanical work performed by the human body and estimate subsequent metabolic energy using predictive algorithmic models. Nineteen University students participated in a repeated measures experiment performing four fundamental movements (arm swings, standing jumps, body-weight squats, and jumping jacks). Metabolic energy was captured using a Cortex Metamax 3B automated gas analysis system with mechanical movement captured by the combined motion data from two Kinect cameras. Estimations of the body segment properties, such as segment mass, length, centre of mass position, and radius of gyration, were calculated from the Zatsiorsky-Seluyanov's equations of de Leva, with adjustment made for posture cost. GPML toolbox implementation of the Gaussian Process Regression, a locally weighted k-Nearest Neighbour Regression, and a linear regression technique were evaluated for their performance on predicting the metabolic cost from new feature vectors. The experimental results show that Gaussian Process Regression outperformed the other two techniques by a small margin. This study demonstrated that physical activity energy expenditure during exercise, using the Kinect camera as a motion capture system, can be estimated from segmental mechanical work. Estimates for high-energy activities, such as standing jumps and jumping jacks, can be made accurately, but for low-energy activities, such as squatting, the posture of static poses should be considered as a contributing factor. When translated into the active video gaming environment, the results could be incorporated into game play to more accurately control the energy expenditure requirements. PMID:26000460

  13. [The taphonomic aspects of cadaverous changes in corpses, buried in the plastic foils].

    PubMed

    Stuller, F; Straka, L; Macko, V; Krivos, D; Krajcovic, J; Novomeský, F

    2008-10-01

    The forensic expertise of the 6 human bodies, being murdered in organised crime activities, had been realised by the authors. All the cadavers were packed in plastic bags or plastic foils, then buried to the illegal graves, being prepared in advance. The detail overlook and autopsy of the bodies had disclosed, that due of almost airtight sealing of the cadavers in plastic materials, the postmortal cadaverous changes went on much slower and were manifested under a different picture, as seen in the human cadavers being buried in the standard wooden coffins. The authors point out the peculiarities of such a postmortal changes, with particular focusing on the estimation of postmortal period.

  14. Association between body mass index and body fat in 9–11-year-old children from countries spanning a range of human development

    PubMed Central

    Katzmarzyk, P T; Barreira, T V; Broyles, S T; Chaput, J-P; Fogelholm, M; Hu, G; Kuriyan, R; Kurpad, A; Lambert, E V; Maher, C; Maia, J; Matsudo, V; Olds, T; Onywera, V; Sarmiento, O L; Standage, M; Tremblay, M S; Tudor-Locke, C; Zhao, P; Church, T S

    2015-01-01

    The purpose was to assess associations between body mass index (BMI) and body fat in a multinational sample of 9–11-year-old children. The sample included 7265 children from countries ranging in human development. Total body fat (TBF) and percentage body fat (PBF) were measured with a Tanita SC-240 scale and BMI z-scores (BMIz) and percentiles were computed using reference data from the World Health Organization and the U.S. Centers for Disease Control and Prevention, respectively. Mean PBF at BMIz values of −1, 0 and +1 were estimated using multilevel models. Correlations between BMI and TBF were >0.90 in all countries, and correlations between BMI and PBF ranged from 0.76 to 0.96. Boys from India had higher PBF than boys from several other countries at all levels of BMIz. Kenyan girls had lower levels of PBF than girls from several other countries at all levels of BMIz. Boys and girls from Colombia had higher values of PBF at BMIz=−1, whereas Colombian boys at BMIz 0 and +1 also had higher values of PBF than boys in other countries. Our results show a consistently high correlation between BMI and adiposity in children from countries representing a wide range of human development. PMID:27152184

  15. Comparison of the Lund and Browder table to computed tomography scan three-dimensional surface area measurement for a pediatric cohort.

    PubMed

    Rumpf, R Wolfgang; Stewart, William C L; Martinez, Stephen K; Gerrard, Chandra Y; Adolphi, Natalie L; Thakkar, Rajan; Coleman, Alan; Rajab, Adrian; Ray, William C; Fabia, Renata

    2018-01-01

    Treating burns effectively requires accurately assessing the percentage of the total body surface area (%TBSA) affected by burns. Current methods for estimating %TBSA, such as Lund and Browder (L&B) tables, rely on historic body statistics. An increasingly obese population has been blamed for increasing errors in %TBSA estimates. However, this assumption has not been experimentally validated. We hypothesized that errors in %TBSA estimates using L&B were due to differences in the physical proportions of today's children compared with children in the early 1940s when the chart was developed and that these differences would appear as body mass index (BMI)-associated systematic errors in the L&B values versus actual body surface areas. We measured the TBSA of human pediatric cadavers using computed tomography scans. Subjects ranged from 9 mo to 15 y in age. We chose outliers of the BMI distribution (from the 31st percentile at the low through the 99th percentile at the high). We examined surface area proportions corresponding to L&B regions. Measured regional proportions based on computed tomography scans were in reasonable agreement with L&B, even with subjects in the tails of the BMI range. The largest deviation was 3.4%, significantly less than the error seen in real-world %TBSA estimates. While today's population is more obese than those studied by L&B, their body region proportions scale surprisingly well. The primary error in %TBSA estimation is not due to changing physical proportions of today's children and may instead lie in the application of the L&B table. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Hierarchical information fusion for global displacement estimation in microsensor motion capture.

    PubMed

    Meng, Xiaoli; Zhang, Zhi-Qiang; Wu, Jian-Kang; Wong, Wai-Choong

    2013-07-01

    This paper presents a novel hierarchical information fusion algorithm to obtain human global displacement for different gait patterns, including walking, running, and hopping based on seven body-worn inertial and magnetic measurement units. In the first-level sensor fusion, the orientation for each segment is achieved by a complementary Kalman filter (CKF) which compensates for the orientation error of the inertial navigation system solution through its error state vector. For each foot segment, the displacement is also estimated by the CKF, and zero velocity update is included for the drift reduction in foot displacement estimation. Based on the segment orientations and left/right foot locations, two global displacement estimates can be acquired from left/right lower limb separately using a linked biomechanical model. In the second-level geometric fusion, another Kalman filter is deployed to compensate for the difference between the two estimates from the sensor fusion and get more accurate overall global displacement estimation. The updated global displacement will be transmitted to left/right foot based on the human lower biomechanical model to restrict the drifts in both feet displacements. The experimental results have shown that our proposed method can accurately estimate human locomotion for the three different gait patterns with regard to the optical motion tracker.

  17. The Human Appropriation of Ecosystem Service Values (HAESV) in the Sundarban Biosphere Region Using Biophysical Quantification Approach

    NASA Astrophysics Data System (ADS)

    Sannigrahi, S.; Paul, S. K.; Sen, S.

    2017-12-01

    Human appropriation, especially unusual changes in land-use and land cover, significantly affects ecosystem services and functions. Driven by the growth of the population and the economy, human demands on earth's land surface have increased dramatically in the past 50 - 100 years. The area studied was divided into six major categories; cropland, mangrove forest, sparse vegetation, built-up urban area, water bodies and sandy coast, and the land coverage was calculated for the years 1973, 1988, 2002 and 2013. The spatial explicit value of the primary regulatory and supporting ecosystem services (climate regulation, raw material production, water regulation) were quantified through the indirect market valuation approach. A light use efficiency based ecosystem model, i.e. Carnegie- Ames-Stanford-Approach (CASA) was employed to estimate the carbon sequestration and oxygen production services of the ecosystem. The ArcGIS matrix transform approach calculated LULC dynamics among the classes. Investigation revealed that the built-up urban area increased from 42.9 km2 in 1973 to 308 km2 in 2013 with a 6.6 km2 yr-1 expansion rate. Similarly, water bodies (especially inland water bodies increased dramatically in the north central region) increased from 3392.1 sq.km in 1973 to 5420 sq.km in 2013 at the expense of semi-natural and natural land resulting in significant changes of ecological and ecosystem services. However, the area occupied by dense mangrove forest decreased substantially during the 40 years (1973 -2013); it was recorded to cover 2294 km2 in 1973 and 1820 km2 in 2013. The results showed that the estimated regulatory and supporting ecosystem services respond quite differently to human appropriation across the regions in both the economic and ecological dimensions. While evaluating the trade-of between human appropriation and ecosystem service changes, it has been estimated that the ecosystem service value of organic matter provision services decreased from 755 US ha-1 in 2000 to 608 US ha-1 in 2013. Therefore, the rigorous and centralised policy for sustainable and regionally balanced land-use planning has been essential in the recent era for economic viability, and ecosystem preservation, to prevent undesirable outcomes.

  18. Dynamics of the oral microbiota as a tool to estimate time since death.

    PubMed

    Adserias-Garriga, J; Quijada, N M; Hernandez, M; Rodríguez Lázaro, D; Steadman, D; Garcia-Gil, L J

    2017-06-27

    The oral cavity harbors one of the most diverse microbiomes in the human body. It has been shown to be the second most complex in the body after the gastrointestinal tract. Upon death, the indigenous microorganisms lead to the decomposition of the carcass. Therefore, the oral cavity and gastrointestinal tract microbiomes play a key role in human decomposition. The aim of the present study is to monitor the microbiome of decaying bodies on a daily basis and to identify signature bacterial taxa, that can improve postmortem interval estimation. Three individuals (one male and two female) donated to the University of Tennessee Forensic Anthropology Center for the W.M. Bass Donated Skeletal Collection were studied. Oral swab samples were taken daily throughout the different stages of cadaveric putrefaction. DNA was extracted and analyzed by next-generation sequencing techniques. The three cadavers showed similar overall successional changes during the decomposition process. Firmicutes and Actinobacteria are the predominant phyla in the fresh stage. The presence of Tenericutes corresponds to bloat stage. Firmicutes is the predominant phylum in advanced decay, but the Firmicutes community is a different one from the predominant Firmicutes of the fresh stage. This study depicts the thanatomicrobiome successional changes in the oral cavity, and highlights its potential use in forensic cases as a quantitative and objective approach to estimate postmortem interval, from an ecological rationale. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Maggot development during morgue storage and its effect on estimating the post-mortem interval.

    PubMed

    Huntington, Timothy E; Higley, Leon G; Baxendale, Frederick P

    2007-03-01

    When insect evidence is obtained during autopsy, forensic entomologists make decisions regarding the effects of low-temperature (-1 degrees C to 4 degrees C) storage of the body and associated insects when estimating the post-mortem interval (PMI). To determine the effects of storage in a morgue cooler on the temperature of maggot masses, temperatures inside and outside of body bags containing a human cadaver and porcine cadavers (seven replicates) were measured during storage. Temperatures remained significantly higher (p<0.05) inside of the body bags relative to the cooler, and remained at levels sufficient for maggot feeding and development. If the assumption that no insect development takes place during preautopsy refrigeration is made, potential error rates in PMI estimation of 8.6-12.8% occur. The potential for blow fly larvae to undergo significant development while being stored in the morgue is a possibility that forensic entomologists should consider during an investigation involving samples collected from autopsy. Case and experimental evidence also demonstrate that substantial tissue loss can occur from maggot feeding during morgue storage.

  20. A kinematic model to estimate the effective dose of radioactive isotopes in the human body for radiological protection

    NASA Astrophysics Data System (ADS)

    Sasaki, S.; Yamada, T.

    2013-12-01

    The great earthquake attacked the north-east area in Japan in March 11, 2011. The system of electrical facilities to control Fukushima Daiichi nuclear power station was completely destroyed by the following tsunamis. From the damaged reactor containment vessels, an amount of radioactive substances had leaked and been diffused in the vicinity of this station. Radiological internal exposure becomes a serious social issue both in Japan and all over the world. The present study provides an easily understandable, kinematic-based model to estimate the effective dose of radioactive substances in a human body by simplified the complicated mechanism of metabolism. International Commission on Radiological Protection (ICRP) has developed an exact model, which is well-known as a standard method to calculate the effective dose for radiological protection. However, owing to that the above method accord too much with the actual mechanism of metabolism in human bodies, it becomes rather difficult for non-professional people of radiology to gasp the whole images of the movement and the influences of radioactive substances in a human body. Therefore, in the present paper we propose a newly-derived and easily-understandable model to estimate the effective dose. The present method is very similar with the traditional and conventional hydrological tank model. Ingestion flux of radioactive substances corresponds to rain intensity and the storage of radioactive substances to the water storage in a basin in runoff analysis. The key of this method is to estimate the energy radiated from the radioactive nuclear disintegration of an atom by using classical theory of E. Fermi of beta decay and special relativity for various kinds of radioactive atoms. The parameters used in this study are only physical half-time and biological half-time, and there are no intentional and operational parameters of coefficients to adjust our theoretical runoff to observation of ICRP. Figure.1 compares time series of effective cesium-137 dose according to age calculated by ICRP software with calculated by the present method. Plots are calculated values by ICRP, the solid line is analytic solution given from the present method. It should be noted that the present study does not consider complicated mechanism, but it could give equally accurate results comparing to existing research. Time series of effective Cs-137 dose according to age when food contains 1 Bq/year is ingested for 1 year. (Plots are calculated values by ICRP. The solid line is analytic solution given from the present method)

  1. Development of a human body finite element model with multiple muscles and their controller for estimating occupant motions and impact responses in frontal crash situations.

    PubMed

    Iwamoto, Masami; Nakahira, Yuko; Kimpara, Hideyuki; Sugiyama, Takahiko; Min, Kyuengbo

    2012-10-01

    A few reports suggest differences in injury outcomes between cadaver tests and real-world accidents under almost similar conditions. This study hypothesized that muscle activity could primarily cause the differences, and then developed a human body finite element (FE) model with individual muscles. Each muscle was modeled as a hybrid model of bar elements with active properties and solid elements with passive properties. The model without muscle activation was firstly validated against five series of cadaver test data on impact responses in the anterior-posterior direction. The model with muscle activation levels estimated based on electromyography (EMG) data was secondly validated against four series of volunteer test data on bracing effects for stiffness and thickness of an upper arm muscle, and braced driver's responses under a static environment and a brake deceleration. A muscle controller using reinforcement learning (RL), which is a mathematical model of learning process in the basal ganglia associated with human postural controls, were newly proposed to estimate muscle activity in various occupant conditions including inattentive and attentive conditions. Control of individual muscles predicted by RL reproduced more human like head-neck motions than conventional control of two groups of agonist and antagonist muscles. The model and the controller demonstrated that head-neck motions of an occupant under an impact deceleration of frontal crash were different in between a bracing condition with maximal braking force and an occupant condition predicted by RL. The model and the controller have the potential to investigate muscular effects in various occupant conditions during frontal crashes.

  2. Application of a Sub-set of Skinfold Sites for Ultrasound Measurement of Subcutaneous Adiposity and Percentage Body Fat Estimation in Athletes.

    PubMed

    O'Neill, D C; Cronin, O; O'Neill, S B; Woods, T; Keohane, D M; Molloy, M G; Falvey, E C

    2016-05-01

    Body composition assessment is an integral feature of elite sport as optimization facilitates successful performance. This study aims to refine the use of B-mode ultrasound in the assessment of athlete body composition by determining suitable sites for measurement. 67 elite athletes recruited from the Human Performance Laboratory, University College Cork, Ireland, underwent dual measurement of body composition. Subcutaneous adipose tissue thickness at 7 anatomical sites were measured using ultrasound and compared to percentage body fat values determined using Dual-Energy X-ray Absorptiometry. Multiple linear regressions were performed and an equation to predict percentage body fat was derived. The present study found subcutaneous adipose tissue depths at the triceps, biceps, anterior thigh and supraspinale sites correlated significantly with percentage body fat by X-ray absorptiometry (all p<0.05). Summation of the depths at these locations correlated strongly with percentage body fat by Dual-Energy X-ray Absorptiometry (R²=0.879). The triceps, biceps, anterior thigh and supraspinale sites are suitable anatomical landmarks for the estimation of %BF using B-mode ultrasound. Use of B-mode ultrasound in the assessment of athlete body composition confers many benefits including lack of ionising radiation and its potential to be used as a portable field tool. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Enhanced Gender Recognition System Using an Improved Histogram of Oriented Gradient (HOG) Feature from Quality Assessment of Visible Light and Thermal Images of the Human Body.

    PubMed

    Nguyen, Dat Tien; Park, Kang Ryoung

    2016-07-21

    With higher demand from users, surveillance systems are currently being designed to provide more information about the observed scene, such as the appearance of objects, types of objects, and other information extracted from detected objects. Although the recognition of gender of an observed human can be easily performed using human perception, it remains a difficult task when using computer vision system images. In this paper, we propose a new human gender recognition method that can be applied to surveillance systems based on quality assessment of human areas in visible light and thermal camera images. Our research is novel in the following two ways: First, we utilize the combination of visible light and thermal images of the human body for a recognition task based on quality assessment. We propose a quality measurement method to assess the quality of image regions so as to remove the effects of background regions in the recognition system. Second, by combining the features extracted using the histogram of oriented gradient (HOG) method and the measured qualities of image regions, we form a new image features, called the weighted HOG (wHOG), which is used for efficient gender recognition. Experimental results show that our method produces more accurate estimation results than the state-of-the-art recognition method that uses human body images.

  4. Enhanced Gender Recognition System Using an Improved Histogram of Oriented Gradient (HOG) Feature from Quality Assessment of Visible Light and Thermal Images of the Human Body

    PubMed Central

    Nguyen, Dat Tien; Park, Kang Ryoung

    2016-01-01

    With higher demand from users, surveillance systems are currently being designed to provide more information about the observed scene, such as the appearance of objects, types of objects, and other information extracted from detected objects. Although the recognition of gender of an observed human can be easily performed using human perception, it remains a difficult task when using computer vision system images. In this paper, we propose a new human gender recognition method that can be applied to surveillance systems based on quality assessment of human areas in visible light and thermal camera images. Our research is novel in the following two ways: First, we utilize the combination of visible light and thermal images of the human body for a recognition task based on quality assessment. We propose a quality measurement method to assess the quality of image regions so as to remove the effects of background regions in the recognition system. Second, by combining the features extracted using the histogram of oriented gradient (HOG) method and the measured qualities of image regions, we form a new image features, called the weighted HOG (wHOG), which is used for efficient gender recognition. Experimental results show that our method produces more accurate estimation results than the state-of-the-art recognition method that uses human body images. PMID:27455264

  5. Urinary C-peptide as a method for monitoring body mass changes in captive bonobos (Pan paniscus).

    PubMed

    Deschner, Tobias; Kratzsch, Jürgen; Hohmann, Gottfried

    2008-11-01

    In recent years methodological improvements have allowed for more precise estimates of nutrient intake in wild primates. However, estimates of energetic condition have remained relatively imprecise due to the difficulties of estimating digestive efficiency and energy expenditure in these animals. In the absence of a reliable intake-expenditure calculation, a method is needed that directly links changes in energetic condition, such as body mass, to physiological changes that can be detected via markers in body excretions such as urine or feces. One promising marker is C-peptide, a metabolic byproduct of insulin synthesis. Here we present the results of a food restriction experiment carried out in a group of captive bonobos (Pan paniscus). We measured changes in food availability and body mass and determined urinary C-peptide levels with the help of a time-resolved fluoroimmunoassay routinely used for measuring C-peptide in human blood. Urinary C-peptide levels decreased during a period of food restriction and increased again when food availability was continuously increased. During this refeeding phase an increase in body mass was significantly correlated with an increase in urinary C-peptide levels. Our results suggest that urinary C-peptide levels are an accurate indicator of individual energy balance. In conclusion, measuring C-peptide in urine is a promising method to quantify the energetic condition of wild apes.

  6. Brain Tissue Compartment Density Estimated Using Diffusion-Weighted MRI Yields Tissue Parameters Consistent With Histology

    PubMed Central

    Sepehrband, Farshid; Clark, Kristi A.; Ullmann, Jeremy F.P.; Kurniawan, Nyoman D.; Leanage, Gayeshika; Reutens, David C.; Yang, Zhengyi

    2015-01-01

    We examined whether quantitative density measures of cerebral tissue consistent with histology can be obtained from diffusion magnetic resonance imaging (MRI). By incorporating prior knowledge of myelin and cell membrane densities, absolute tissue density values were estimated from relative intra-cellular and intra-neurite density values obtained from diffusion MRI. The NODDI (neurite orientation distribution and density imaging) technique, which can be applied clinically, was used. Myelin density estimates were compared with the results of electron and light microscopy in ex vivo mouse brain and with published density estimates in a healthy human brain. In ex vivo mouse brain, estimated myelin densities in different sub-regions of the mouse corpus callosum were almost identical to values obtained from electron microscopy (Diffusion MRI: 42±6%, 36±4% and 43±5%; electron microscopy: 41±10%, 36±8% and 44±12% in genu, body and splenium, respectively). In the human brain, good agreement was observed between estimated fiber density measurements and previously reported values based on electron microscopy. Estimated density values were unaffected by crossing fibers. PMID:26096639

  7. Comparison of human radiation exchange models in outdoor areas

    NASA Astrophysics Data System (ADS)

    Park, Sookuk; Tuller, Stanton E.

    2011-10-01

    Results from the radiation components of seven different human thermal exchange models/methods are compared. These include the Burt, COMFA, MENEX, OUT_SET* and RayMan models, the six-directional method and the new Park and Tuller model employing projected area factors ( f p) and effective radiation area factors ( f eff) determined from a sample of normal- and over-weight Canadian Caucasian adults. Input data include solar and longwave radiation measured during a clear summer day in southern Ontario. Variations between models came from differences in f p and f eff and different estimates of longwave radiation from the open sky. The ranges between models for absorbed solar, net longwave and net all-wave radiation were 164, 31 and 187 W m-2, respectively. These differentials between models can be significant in total human thermal exchange. Therefore, proper f p and f eff values should be used to make accurate estimation of radiation on the human body surface.

  8. Vitamin K-induced effects on body fat and weight: results from a 3-year vitamin K2 intervention study.

    PubMed

    Knapen, M H J; Jardon, K M; Vermeer, C

    2018-01-01

    Vitamin K status has been linked to fat and glucose metabolism by several authors, but whether high vitamin K intake influences body weight or composition has remained unclear. Here we tested the hypothesis that increased vitamin K intake decreases body fat or fat distribution. In a randomized placebo-controlled human intervention trial, 214 postmenopausal women, 55-65 years of age, received either 180 mcg/day of vitamin K2 (menaquinone-7, MK-7) or placebo for 3 years. Osteocalcin (OC) carboxylation was used as a marker for vitamin K status, and fat distribution was assessed by dual-energy X-ray absorptiometry total body scan. In the total cohort, MK-7 supplementation increased circulating carboxylated OC (cOC) but had no effect on body composition. In those with an above-median response in OC carboxylation ('good responders'), MK-7 treatment resulted in a significant increase in total and human molecular weight adiponectin and a decrease in abdominal fat mass and in the estimated visceral adipose tissue area compared with the placebo group and the poor responders. The fact that changes in body composition measures or markers for fat or glucose metabolism were not associated with changes in uncarboxylated OC (ucOC) does not support the assumption that ucOC stimulates fat metabolism in humans. Instead, high vitamin K2 intake may support reducing body weight, abdominal and visceral fat, notably in subjects showing a strong increase in cOC. A causal relation between the changes in cOC and body fat or distribution cannot be concluded from these data.

  9. Soft tissues store and return mechanical energy in human running.

    PubMed

    Riddick, R C; Kuo, A D

    2016-02-08

    During human running, softer parts of the body may deform under load and dissipate mechanical energy. Although tissues such as the heel pad have been characterized individually, the aggregate work performed by all soft tissues during running is unknown. We therefore estimated the work performed by soft tissues (N=8 healthy adults) at running speeds ranging 2-5 m s(-1), computed as the difference between joint work performed on rigid segments, and whole-body estimates of work performed on the (non-rigid) body center of mass (COM) and peripheral to the COM. Soft tissues performed aggregate negative work, with magnitude increasing linearly with speed. The amount was about -19 J per stance phase at a nominal 3 m s(-1), accounting for more than 25% of stance phase negative work performed by the entire body. Fluctuations in soft tissue mechanical power over time resembled a damped oscillation starting at ground contact, with peak negative power comparable to that for the knee joint (about -500 W). Even the positive work from soft tissue rebound was significant, about 13 J per stance phase (about 17% of the positive work of the entire body). Assuming that the net dissipative work is offset by an equal amount of active, positive muscle work performed at 25% efficiency, soft tissue dissipation could account for about 29% of the net metabolic expenditure for running at 5 m s(-1). During running, soft tissue deformations dissipate mechanical energy that must be offset by active muscle work at non-negligible metabolic cost. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Interindividual variation in DNA methylation at a putative POMC metastable epiallele is associated with obesity

    USDA-ARS?s Scientific Manuscript database

    The estimated heritability of human BMI is close to 75%, but identified genetic variants explain only a small fraction of interindividual body-weight variation. Inherited epigenetic variants identified in mouse models named "metastable epialleles" could in principle explain this "missing heritabilit...

  11. Estimation of decay rates for fecal indicator bacteria and bacterial pathogens in agricultural field-applied manure

    EPA Science Inventory

    Field-applied manure is an important source of pathogenic exposure in surface water bodies for humans and ecological receptors. We analyzed the persistence and decay of fecal indicator bacteria and bacterial pathogens from three sources (cattle, poultry, swine) for agricultural f...

  12. Development and application of traffic density-based parameters for studying near-road air pollutant exposure

    EPA Science Inventory

    Increasingly human populations are living and/or working in close proximity to heavily travelled roadways. There is a growing body of research indicating a variety of health conditions are adversely affected by near-road air pollutants. To reliably estimate the health risk assoc...

  13. Development and application of traffic density-based Parameters for near-road air pollutant exposure

    EPA Science Inventory

    Increasingly human populations are living and/or working in close proximity to heavily travelled roadways. There is a growing body of research indicating a variety of health conditions are adversely affected by near-road air pollutants. To reliably estimate the health risk assoc...

  14. PBDES IN US NURSING MOTHERS' MILK, FOOD, AND ELECTRONICS: LEVEL AND ESTIMATED INTAKE BY VARIOUS ROUTES

    EPA Science Inventory

    ABSTRACT BODY: Polybrominated diphenylether (PBDE) flame retardants are currently used in the USA to a larger extent than in Europe. They have recently been measured in human tissues, fish, dust and other environmental samples. Although animal studies find toxicity including carc...

  15. Simplified quantification and whole-body distribution of [18F]FE-PE2I in nonhuman primates: prediction for human studies.

    PubMed

    Varrone, Andrea; Gulyás, Balázs; Takano, Akihiro; Stabin, Michael G; Jonsson, Cathrine; Halldin, Christer

    2012-02-01

    [(18)F]FE-PE2I is a promising dopamine transporter (DAT) radioligand. In nonhuman primates, we examined the accuracy of simplified quantification methods and the estimates of radiation dose of [(18)F]FE-PE2I. In the quantification study, binding potential (BP(ND)) values previously reported in three rhesus monkeys using kinetic and graphical analyses of [(18)F]FE-PE2I were used for comparison. BP(ND) using the cerebellum as reference region was obtained with four reference tissue methods applied to the [(18)F]FE-PE2I data that were compared with the kinetic and graphical analyses. In the whole-body study, estimates of adsorbed radiation were obtained in two cynomolgus monkeys. All reference tissue methods provided BP(ND) values within 5% of the values obtained with the kinetic and graphical analyses. The shortest imaging time for stable BP(ND) estimation was 54 min. The average effective dose of [(18)F]FE-PE2I was 0.021 mSv/MBq, similar to 2-deoxy-2-[(18)F]fluoro-d-glucose. The results in nonhuman primates suggest that [(18)F]FE-PE2I is suitable for accurate and stable DAT quantification, and its radiation dose estimates would allow for a maximal administered radioactivity of 476 MBq in human subjects. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Effects of the TRPV1 antagonist ABT-102 on body temperature in healthy volunteers: pharmacokinetic/pharmacodynamic analysis of three phase 1 trials

    PubMed Central

    Othman, Ahmed A; Nothaft, Wolfram; Awni, Walid M; Dutta, Sandeep

    2013-01-01

    Aim To characterize quantitatively the relationship between ABT-102, a potent and selective TRPV1 antagonist, exposure and its effects on body temperature in humans using a population pharmacokinetic/pharmacodynamic modelling approach. Methods Serial pharmacokinetic and body temperature (oral or core) measurements from three double-blind, randomized, placebo-controlled studies [single dose (2, 6, 18, 30 and 40 mg, solution formulation), multiple dose (2, 4 and 8 mg twice daily for 7 days, solution formulation) and multiple-dose (1, 2 and 4 mg twice daily for 7 days, solid dispersion formulation)] were analyzed. nonmem was used for model development and the model building steps were guided by pre-specified diagnostic and statistical criteria. The final model was qualified using non-parametric bootstrap and visual predictive check. Results The developed body temperature model included additive components of baseline, circadian rhythm (cosine function of time) and ABT-102 effect (Emax function of plasma concentration) with tolerance development (decrease in ABT-102 Emax over time). Type of body temperature measurement (oral vs. core) was included as a fixed effect on baseline, amplitude of circadian rhythm and residual error. The model estimates (95% bootstrap confidence interval) were: baseline oral body temperature, 36.3 (36.3, 36.4)°C; baseline core body temperature, 37.0 (37.0, 37.1)°C; oral circadian amplitude, 0.25 (0.22, 0.28)°C; core circadian amplitude, 0.31 (0.28, 0.34)°C; circadian phase shift, 7.6 (7.3, 7.9) h; ABT-102 Emax, 2.2 (1.9, 2.7)°C; ABT-102 EC50, 20 (15, 28) ng ml−1; tolerance T50, 28 (20, 43) h. Conclusions At exposures predicted to exert analgesic activity in humans, the effect of ABT-102 on body temperature is estimated to be 0.6 to 0.8°C. This effect attenuates within 2 to 3 days of dosing. PMID:22966986

  17. Learning Multiple Band-Pass Filters for Sleep Stage Estimation: Towards Care Support for Aged Persons

    NASA Astrophysics Data System (ADS)

    Takadama, Keiki; Hirose, Kazuyuki; Matsushima, Hiroyasu; Hattori, Kiyohiko; Nakajima, Nobuo

    This paper proposes the sleep stage estimation method that can provide an accurate estimation for each person without connecting any devices to human's body. In particular, our method learns the appropriate multiple band-pass filters to extract the specific wave pattern of heartbeat, which is required to estimate the sleep stage. For an accurate estimation, this paper employs Learning Classifier System (LCS) as the data-mining techniques and extends it to estimate the sleep stage. Extensive experiments on five subjects in mixed health confirm the following implications: (1) the proposed method can provide more accurate sleep stage estimation than the conventional method, and (2) the sleep stage estimation calculated by the proposed method is robust regardless of the physical condition of the subject.

  18. Real-time upper-body human pose estimation from depth data using Kalman filter for simulator

    NASA Astrophysics Data System (ADS)

    Lee, D.; Chi, S.; Park, C.; Yoon, H.; Kim, J.; Park, C. H.

    2014-08-01

    Recently, many studies show that an indoor horse riding exercise has a positive effect on promoting health and diet. However, if a rider has an incorrect posture, it will be the cause of back pain. In spite of this problem, there is only few research on analyzing rider's posture. Therefore, the purpose of this study is to estimate a rider pose from a depth image using the Asus's Xtion sensor in real time. In the experiments, we show the performance of our pose estimation algorithm in order to comparing the results between our joint estimation algorithm and ground truth data.

  19. Comparative analysis of bones, mites, soil chemistry, nematodes and soil micro-eukaryotes from a suspected homicide to estimate the post-mortem interval.

    PubMed

    Szelecz, Ildikó; Lösch, Sandra; Seppey, Christophe V W; Lara, Enrique; Singer, David; Sorge, Franziska; Tschui, Joelle; Perotti, M Alejandra; Mitchell, Edward A D

    2018-01-08

    Criminal investigations of suspected murder cases require estimating the post-mortem interval (PMI, or time after death) which is challenging for long PMIs. Here we present the case of human remains found in a Swiss forest. We have used a multidisciplinary approach involving the analysis of bones and soil samples collected beneath the remains of the head, upper and lower body and "control" samples taken a few meters away. We analysed soil chemical characteristics, mites and nematodes (by microscopy) and micro-eukaryotes (by Illumina high throughput sequencing). The PMI estimate on hair 14 C-data via bomb peak radiocarbon dating gave a time range of 1 to 3 years before the discovery of the remains. Cluster analyses for soil chemical constituents, nematodes, mites and micro-eukaryotes revealed two clusters 1) head and upper body and 2) lower body and controls. From mite evidence, we conclude that the body was probably brought to the site after death. However, chemical analyses, nematode community analyses and the analyses of micro-eukaryotes indicate that decomposition took place at least partly on site. This study illustrates the usefulness of combining several lines of evidence for the study of homicide cases to better calibrate PMI inference tools.

  20. Development and validation of a predictive equation for lean body mass in children and adolescents.

    PubMed

    Foster, Bethany J; Platt, Robert W; Zemel, Babette S

    2012-05-01

    Lean body mass (LBM) is not easy to measure directly in the field or clinical setting. Equations to predict LBM from simple anthropometric measures, which account for the differing contributions of fat and lean to body weight at different ages and levels of adiposity, would be useful to both human biologists and clinicians. To develop and validate equations to predict LBM in children and adolescents across the entire range of the adiposity spectrum. Dual energy X-ray absorptiometry was used to measure LBM in 836 healthy children (437 females) and linear regression was used to develop sex-specific equations to estimate LBM from height, weight, age, body mass index (BMI) for age z-score and population ancestry. Equations were validated using bootstrapping methods and in a local independent sample of 332 children and in national data collected by NHANES. The mean difference between measured and predicted LBM was - 0.12% (95% limits of agreement - 11.3% to 8.5%) for males and - 0.14% ( - 11.9% to 10.9%) for females. Equations performed equally well across the entire adiposity spectrum, as estimated by BMI z-score. Validation indicated no over-fitting. LBM was predicted within 5% of measured LBM in the validation sample. The equations estimate LBM accurately from simple anthropometric measures.

  1. Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition.

    PubMed

    Wang, Fu-Tai; Chan, Hsiao-Lung; Wang, Chun-Li; Jian, Hung-Ming; Lin, Sheng-Hsiung

    2015-07-07

    Impedance plethysmography provides a way to measure respiratory activity by sensing the change of thoracic impedance caused by inspiration and expiration. This measurement imposes little pressure on the body and uses the human body as the sensor, thereby reducing the need for adjustments as body position changes and making it suitable for long-term or ambulatory monitoring. The empirical mode decomposition (EMD) can decompose a signal into several intrinsic mode functions (IMFs) that disclose nonstationary components as well as stationary components and, similarly, capture respiratory episodes from thoracic impedance. However, upper-body movements usually produce motion artifacts that are not easily removed by digital filtering. Moreover, large motion artifacts disable the EMD to decompose respiratory components. In this paper, motion artifacts are detected and replaced by the data mirrored from the prior and the posterior before EMD processing. A novel intrinsic respiratory reconstruction index that considers both global and local properties of IMFs is proposed to define respiration-related IMFs for respiration reconstruction and instantaneous respiratory estimation. Based on the experiments performing a series of static and dynamic physical activates, our results showed the proposed method had higher cross correlations between respiratory frequencies estimated from thoracic impedance and those from oronasal airflow based on small window size compared to the Fourier transform-based method.

  2. Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition

    PubMed Central

    Wang, Fu-Tai; Chan, Hsiao-Lung; Wang, Chun-Li; Jian, Hung-Ming; Lin, Sheng-Hsiung

    2015-01-01

    Impedance plethysmography provides a way to measure respiratory activity by sensing the change of thoracic impedance caused by inspiration and expiration. This measurement imposes little pressure on the body and uses the human body as the sensor, thereby reducing the need for adjustments as body position changes and making it suitable for long-term or ambulatory monitoring. The empirical mode decomposition (EMD) can decompose a signal into several intrinsic mode functions (IMFs) that disclose nonstationary components as well as stationary components and, similarly, capture respiratory episodes from thoracic impedance. However, upper-body movements usually produce motion artifacts that are not easily removed by digital filtering. Moreover, large motion artifacts disable the EMD to decompose respiratory components. In this paper, motion artifacts are detected and replaced by the data mirrored from the prior and the posterior before EMD processing. A novel intrinsic respiratory reconstruction index that considers both global and local properties of IMFs is proposed to define respiration-related IMFs for respiration reconstruction and instantaneous respiratory estimation. Based on the experiments performing a series of static and dynamic physical activates, our results showed the proposed method had higher cross correlations between respiratory frequencies estimated from thoracic impedance and those from oronasal airflow based on small window size compared to the Fourier transform-based method. PMID:26198231

  3. Evaluation of [18F]Mefway biodistribution and dosimetry based on whole-body PET imaging of mice.

    PubMed

    Constantinescu, Cristian C; Sevrioukov, Evgueni; Garcia, Adriana; Pan, Min-Liang; Mukherjee, Jogeshwar

    2013-04-01

    [(18)F]Mefway is a novel radiotracer specific to the serotonin 5-HT1A receptor class. In preparation for using this tracer in humans, we have performed whole-body PET studies in mice to evaluate the biodistribution and dosimetry of [(18)F]Mefway. Six mice (three females and three males) received IV injections of [(18)F]Mefway and were scanned for 2 h in an Inveon-dedicated PET scanner. Each animal also received a high-resolution CT scan using an Inveon CT. The CT images were used to draw volume of interest on the following organs: the brain, large intestine, stomach, heart, kidneys, liver, lungs, pancreas, bone, spleen, testes, thymus, gallbladder, uterus, and urinary bladder. All organ time-activity curves without decay correction were normalized to the injected activity. The area under the normalized curves was then used to compute the residence times in each organ. Data were analyzed using PMOD and Matlab software. The absorbed doses in mouse organs were computed using the RAdiation Dose Assessment Resource animal models for dose assessment. The residence times in mouse organs were converted to human values using scale factors based on differences between organ and body weights. OLINDA/EXM 1.1 software was used to compute the absorbed human doses in multiple organs for both female and male phantoms. The highest mouse residence times were found in the liver, urinary bladder, and kidneys. The largest doses in mice were found in the urinary bladder (critical organ), kidney, and liver for both females and males, indicating primary elimination via urinary system. The projected human effective doses were 1.21E - 02 mSv/MBq for the adult female model and 1.13E - 02 mSv/MBq for the adult male model. The estimated human biodistribution of [(18)F]Mefway was similar to that of [(11)C]WAY 100,635, a 5-HT1A tracer for which dosimetry has been evaluated in humans. The elimination of radiotracer was primarily via the kidney and urinary bladder with the urinary bladder being the critical organ. Whole-body mouse imaging can be used as a preclinical tool to provide initial estimates of the absorbed doses of [(18)F]Mefway in humans.

  4. Comparison of SPECT aerosol deposition data with a human respiratory tract model.

    PubMed

    Fleming, John S; Epps, Ben P; Conway, Joy H; Martonen, Ted B

    2006-01-01

    Three-dimensional (3D) radionuclide imaging provides detailed information on the distribution of inhaled aerosol material within the body. Analysis of the data can provide estimates of the deposition per airway generation. In this study, two different nebulizers have been used to deliver radiolabeled aerosols of different particle size to 12 human subjects. Medical imaging has been used to assess the deposition in the body. The deposition pattern has also been estimated using the International Commission on Radiological Protection (ICRP) empirical model and compared to values obtained by experiment. The results showed generally good agreement between model and experiment for both aerosols for the deposition in the extrathoracic and conducting airways. However, there were significant differences in the fate of the remainder of the aerosol between the amount deposited in the alveolar region and that exhaled. The inter-subject variability of deposition predicted by the model was significantly less than that measured, for all regions of the body. The model predicted quite well the differences in deposition distribution pattern between the two aerosols. In conclusion, this study has shown that the ICPR model of inhaled aerosol deposition shows areas of good agreement with results from experiment. However, there are also areas of disagreement, which may be explained by hygroscopic particle growth and individual variation in airway anatomy.

  5. Time-lapse imaging of human heart motion with switched array UWB radar.

    PubMed

    Brovoll, Sverre; Berger, Tor; Paichard, Yoann; Aardal, Øyvind; Lande, Tor Sverre; Hamran, Svein-Erik

    2014-10-01

    Radar systems for detection of human heartbeats have mostly been single-channel systems with limited spatial resolution. In this paper, a radar system for ultra-wideband (UWB) imaging of the human heart is presented. To make the radar waves penetrate the human tissue the antenna is placed very close to the body. The antenna is an array with eight elements, and an antenna switch system connects the radar to the individual elements in sequence to form an image. Successive images are used to build up time-lapse movies of the beating heart. Measurements on a human test subject are presented and the heart motion is estimated at different locations inside the body. The movies show rhythmic motion consistent with the beating heart, and the location and shape of the reflections correspond well with the expected response form the heart wall. The spatial dependent heart motion is compared to ECG recordings, and it is confirmed that heartbeat modulations are seen in the radar data. This work shows that radar imaging of the human heart may provide valuable information on the mechanical movement of the heart.

  6. Probabilistic models in human sensorimotor control

    PubMed Central

    Wolpert, Daniel M.

    2009-01-01

    Sensory and motor uncertainty form a fundamental constraint on human sensorimotor control. Bayesian decision theory (BDT) has emerged as a unifying framework to understand how the central nervous system performs optimal estimation and control in the face of such uncertainty. BDT has two components: Bayesian statistics and decision theory. Here we review Bayesian statistics and show how it applies to estimating the state of the world and our own body. Recent results suggest that when learning novel tasks we are able to learn the statistical properties of both the world and our own sensory apparatus so as to perform estimation using Bayesian statistics. We review studies which suggest that humans can combine multiple sources of information to form maximum likelihood estimates, can incorporate prior beliefs about possible states of the world so as to generate maximum a posteriori estimates and can use Kalman filter-based processes to estimate time-varying states. Finally, we review Bayesian decision theory in motor control and how the central nervous system processes errors to determine loss functions and optimal actions. We review results that suggest we plan movements based on statistics of our actions that result from signal-dependent noise on our motor outputs. Taken together these studies provide a statistical framework for how the motor system performs in the presence of uncertainty. PMID:17628731

  7. Attenuation Coefficient Estimation of the Healthy Human Thyroid In Vivo

    NASA Astrophysics Data System (ADS)

    Rouyer, J.; Cueva, T.; Portal, A.; Yamamoto, T.; Lavarello, R.

    Previous studies have demonstrated that attenuation coefficients can be useful towards characterizing thyroid tissues. In this work, ultrasonic attenuation coefficients were estimated from healthy human thyroids in vivo using a clinical scanner. The selected subjects were five young, healthy volunteers (age: 26 ± 6 years old, gender: three females, two males) with no reported history of thyroid diseases, no palpable thyroid nodules, no smoking habits, and body mass index less than 30 kg/m2. Echographic examinations were conducted by a trained sonographer using a SonixTouch system (Ultrasonix Medical Corporation, Richmond, BC) equipped with an L14-5 linear transducer array (nominal center frequency of 10 MHz, transducer footprint of 3.8 cm). Radiofrequency data corresponding to the collected echographic images in both transverse and longitudinal views were digitized at a sampling rate of 40 MHz and processed with Matlab codes (MathWorks, Natick, MA) to estimate attenuation coefficients using the spectral log difference method. The estimation was performed using an analysis bandwidth spanning from 4.0 to 9.0 MHz. The average value of the estimated ultrasonic attenuation coefficients was equal to 1.34 ± 0.15 dB/(cm.MHz). The standard deviation of the estimated average attenuation coefficient across different volunteers suggests a non-negligible inter-subject variability in the ultrasonic attenuation coefficient of the human thyroid.

  8. Beyond Newton's law of cooling - estimation of time since death

    NASA Astrophysics Data System (ADS)

    Leinbach, Carl

    2011-09-01

    The estimate of the time since death and, thus, the time of death is strictly that, an estimate. However, the time of death can be an important piece of information in some coroner's cases, especially those that involve criminal or insurance investigations. It has been known almost from the beginning of time that bodies cool after the internal mechanisms such as circulation of the blood stop. A first attempt to link this phenomenon to the determination of the time of death used a crude linear relationship. Towards the end of the nineteenth century, Newton's law of cooling using body temperature data obtained by the coroner was used to make a more accurate estimate. While based on scientific principles and resulting in a better estimate, Newton's law does not really describe the cooling of a non-homogeneous human body. This article will discuss a more accurate model of the cooling process based on the theoretical work of Marshall and Hoare and the laboratory-based statistical work of Claus Henssge. Using DERIVE®6.10 and the statistical work of Henssge, the double exponential cooling formula developed by Marshall and Hoare will be explored. The end result is a tool that can be used in the field by coroner's scene investigators to determine a 95% confidence interval for the time since death and, thus, the time of death.

  9. Living and working in space; IAA Man in Space Symposium, 9th, Cologne, Federal Republic of Germany, June 17-21, 1991, Selection of Papers

    NASA Technical Reports Server (NTRS)

    Klein, Karl E. (Editor); Contant, Jean-Michel (Editor)

    1992-01-01

    The present symposium on living and working in space encompasses the physiological responses of humans in space and biomedical support for the conditions associated with space travel. Specific physiological issues addressed include cerebral and sensorimotor functions, effects on the cardiovascular and respiratory system, musculoskeletal system, body fluid, hormones and electrolytes, and some orthostatic hypotension mechanisms as countermeasures. The biomedical support techniques examined include selection training, and care, teleoperation and artificial intelligence, robotic automation, bioregenerative life support, and toxic hazard risks in space habitats. Also addressed are determinants of orientation in microgravity, the hormonal control of body fluid metabolism, integrated human-machine intelligence in space machines, and material flow estimation in CELSS.

  10. Estimation of dioxin and furan elimination rates with a pharmacokinetic model.

    PubMed

    Van der Molen, G W; Kooijman, B A; Wittsiepe, J; Schrey, P; Flesch-Janys, D; Slob, W

    2000-01-01

    Quantitative description of the pharmacokinetics of dioxins and furans in humans can be of great help for the assessment of health risks posed by these compounds. To that the elimination rates of sixteen 2,3,7,8-chlorinated dibenzodioxins and dibenzofurans are estimated from both a longitudinal and a cross-sectional data set using the model of Van der Molen et al. [Van der Molen G.W., Kooijman S.A.L.M., and Slob W. A generic toxicokinetic model for persistent lipophilic compounds in humans: an application to TCDD. Fundam Appl Toxicol 1996: 31: 83-94]. In this model the elimination rate is given by the (constant) specific elimination rate multiplied with the ratio between the lipid weight of the liver and total body lipid weight. Body composition, body weight and intake are assumed to depend on age. The elimination rate is, therefore, not constant. For 49-year-old males, the elimination rate estimates range between 0.03 per year for 1,2,3,6,7,8-hexaCDF to 1.0 per year for octaCDF. The elimination rates of the most toxic congeners, 2,3,7,8-tetraCDD, 1,2,3,7,8-pentaCDD, and 2,3,4,7,8-pentaCDF, were estimated at 0.09, 0.06, and 0.07, respectively, based on the cross-sectional data, and 0.11, 0.09, and 0.09 based on the longitudinal data. The elimination rates of dioxins decrease with age between 0.0011 per year for 1,2,3,6,7,8-hexaCDD and 0.0035 per year for 1,2,3,4,6,7,8-heptaCDD. For furans the average decrease is 0.0033 per year. The elimination rates were estimated both from a longitudinal and a cross-sectional data set, and agreed quite well with each other, after taking account of historical changes in average intake levels.

  11. Voltammetry of naltrexone in commercial formulation and human body fluids: Quantification and pharmacokinetic studies.

    PubMed

    Ghoneim, Mohamed M; El-Desoky, Hanaa S; Abdel-Galeil, Mohamed M

    2011-06-01

    Naltrexone HCl (NAL.HCl) has been reduced at the mercury electrode in Britton-Robinson universal buffer of pH values 2-11 with a mechanism involving the quasi-reversible uptake of the first transferring electron followed by a rate-determining protonation step of its C=O double bond at position C-6. Simple, sensitive, selective and reliable linear-sweep and square-wave adsorptive cathodic stripping voltammetry methods have been described for trace quantitation of NAL.HCl in bulk form, commercial formulation and human body fluids without the necessity for sample pretreatment and/or time-consuming extraction steps prior to the analysis. Limits of quantitation of 6.0×10(-9)M and 8.0×10(-10)M NAL.HCl in bulk form or commercial formulation and of 9.0×10(-9) and 1.0×10(-9)M NAL.HCl in spiked human serum samples were achieved by the described linear and square-wave stripping voltammetry methods, respectively. Furthermore, pharmacokinetic parameters of the drug in human plasma samples of healthy volunteers following the administration of an oral single dose of 50mg NAL.HCl (one Revia(®) tablet) were estimated by means of the described square-wave stripping voltammetry method without interferences from the drug's metabolites and/or endogenous human plasma constituents. The estimated pharmacokinetic parameters were favorably compared with those reported in literature. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. A Revised Model for Dosimetry in the Human Small Intestine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John Poston; Nasir U. Bhuiyan; R. Alex Redd

    2005-02-28

    A new model for an adult human gastrointestinal tract (GIT) has been developed for use in internal dose estimations to the wall of the GIT and to the other organs and tissues of the body from radionuclides deposited in the lumenal contents of the five sections of the GIT. These sections were the esophasgus, stomach, small intestine, upper large intestine, and the lower large intestine. The wall of each section was separated from its lumenal contents.

  13. Differences in Cu content in selected mushroom species growing in the same unpolluted areas in Poland.

    PubMed

    Mleczek, Mirosław; Siwulski, Marek; Mikołajczak, Patrycja; Gąsecka, Monika; Rissmann, Iwona; Goliński, Piotr; Sobieralski, Krzysztof

    2015-01-01

    The aim of the study was to estimate copper (Cu) accumulation efficiency in whole-fruiting bodies of 18 edible and non-edible wild growing mushrooms collected from 27 places in the Wielkopolska Voivodeship. Mushrooms were collected each time from the same places to estimate the diversity in Cu accumulation between tested mushroom species within 3 consecutive years of study (2011-2013). The study results revealed various accumulation of Cu in the whole-tested mushroom fruiting bodies. The highest mean accumulation of Cu was observed in Macrolepiota procera (119.4 ± 20.0 mg kg(-1) dm), while the lowest was in Suillus luteus and Russula fellea fruiting bodies (16.1 ± 3.0 and 18.8 ± 4.6 mg kg(-1) dm, respectively). Significant differences in Cu accumulation between mushroom species collected in 2011 and in the two following years (2012 and 2013) were observed. The results indicated that sporadic consumption of these mushrooms was not related to excessive intake of Cu for the human body (no toxic influence on health).

  14. Analysis of patient CT dose data using virtualdose

    NASA Astrophysics Data System (ADS)

    Bennett, Richard

    X-ray computer tomography has many benefits to medical and research applications. Recently, over the last decade CT has had a large increase in usage in hospitals and medical diagnosis. In pediatric care, from 2000 to 2006, abdominal CT scans increased by 49 % and chest CT by 425 % in the emergency room (Broder 2007). Enormous amounts of effort have been performed across multiple academic and government groups to determine an accurate measure of organ dose to patients who undergo a CT scan due to the inherent risks with ionizing radiation. Considering these intrinsic risks, CT dose estimating software becomes a necessary tool that health care providers and radiologist must use to determine many metrics to base the risks versus rewards of having an x-ray CT scan. This thesis models the resultant organ dose as body mass increases for patients with all other related scan parameters fixed. In addition to this,this thesis compares a modern dose estimating software, VirtualDose CT to two other programs, CT-Expo and ImPACT CT. The comparison shows how the software's theoretical basis and the phantom they use to represent the human body affect the range of results in organ dose. CT-Expo and ImPACT CT dose estimating software uses a different model for anatomical representation of the organs in the human body and the results show how that approach dramatically changes the outcome. The results categorizes four datasets as compared to the three software types where the appropriate phantom was available. Modeling was done to simulate chest abdominal pelvis scans and whole body scans. Organ dose difference versus body mass index shows as body mass index (BMI) ranges from 23.5 kg/m 2 to 45 kg/m2 the amount of organ dose also trends a percent change from -4.58 to -176.19 %. Comparing organ dose difference with increasing x-ray tube potential from 120 kVp to 140 kVp the percent change in organ dose increases from 55 % to 65 % across all phantoms. In comparing VirtualDose to CT-Expo for organ dose difference versus age, male phantoms show percent difference of -19 % to 25 % for various organs minus bone surface and breast tissues results. Finally, for organ dose difference across all software for average adult phantom the results range from -45 % to 6 % in the comparison of ImPACT CT to VirtualDose and -27 % to 66 % for the comparison of CT-Expo to VirtualDose. In the comparison for increased BMI (done only in VirtualDose), results show that with all other parameters fixed, the organ dose goes down as BMI increases, which is due to the increase in adipose tissue and bulk of the patient model. The range of results when comparing all the three softwares have a wide range, in some cases greater than 150 %, it is evident that using a different anatomical basis for the human phantom and the theoretical basis for the dose estimation will cause fluctuation in the results. Therefore, choosing the software with the most accurate human phantom will provide a closer range to the true dose to the organ.

  15. Human allometry: adult bodies are more nearly geometrically similar than regression analysis has suggested.

    PubMed

    Burton, Richard F

    2010-01-01

    It is almost a matter of dogma that human body mass in adults tends to vary roughly in proportion to the square of height (stature), as Quetelet stated in 1835. As he realised, perfect isometry or geometric similarity requires that body mass varies with height cubed, so there seems to be a trend for tall adults to be relatively much lighter than short ones. Much evidence regarding component tissues and organs seems to accord with this idea. However, the hypothesis is presented that the proportions of the body are actually very much less size-dependent. Past evidence has mostly been obtained by least-squares regression analysis, but this cannot generally give a true picture of the allometric relationships. This is because there is considerable scatter in the data (leading to a low correlation between mass and height) and because neither variable causally determines the other. The relevant regression equations, though often formulated in logarithmic terms, effectively treat the masses as proportional to (body height)(b). Values of b estimated by regression must usually underestimate the true functional values, doing so especially when mass and height are poorly correlated. It is therefore telling support for the hypothesis that published estimates of b both for the whole body (which range between 1.0 and 2.5) and for its component tissues and organs (which vary even more) correlate with the corresponding correlation coefficients for mass and height. There is no simple statistical technique for establishing the true functional relationships, but Monte Carlo modelling has shown that the results obtained for total body mass are compatible with a true height exponent of three. Other data, on relationships between body mass and the girths of various body parts such as the thigh and chest, are also more consistent with isometry than regression analysis has suggested. This too is demonstrated by modelling. It thus seems that much of anthropometry needs to be re-evaluated. It is not suggested that all organs and tissues scale equally with whole body size.

  16. Biological Monitoring of Air Pollutants and Its Influence on Human Beings

    PubMed Central

    Cen, Shihong

    2015-01-01

    Monitoring air pollutants via plants is an economic, convenient and credible method compared with the traditional ways. Plants show different damage symptoms to different air pollutants, which can be used to determine the species of air pollutants. Besides, pollutants mass concentration scope can be estimated by the damage extent of plants and the span of polluted time. Based on the domestic and foreign research, this paper discusses the principles, mechanism, advantages and disadvantages of plant-monitoring, and exemplifies plenty of such plants and the minimum mass concentration and pollution time of the plants showing damage symptoms. Finally, this paper introduced the human health effects of air pollutants on immune function of the body, such as decrease of the body's immune function, decline of lung function, respiratory and circulatory system changes, inducing and promoting human allergic diseases, respiratory diseases and other diseases. PMID:26628931

  17. An evaluation of soil chemistry in human cadaver decomposition islands: Potential for estimating postmortem interval (PMI).

    PubMed

    Fancher, J P; Aitkenhead-Peterson, J A; Farris, T; Mix, K; Schwab, A P; Wescott, D J; Hamilton, M D

    2017-10-01

    Soil samples from the Forensic Anthropology Research Facility (FARF) at Texas State University, San Marcos, TX, were analyzed for multiple soil characteristics from cadaver decomposition islands to a depth of 5centimeters (cm) from 63 human decomposition sites, as well as depths up to 15cm in a subset of 11 of the cadaver decomposition islands plus control soils. Postmortem interval (PMI) of the cadaver decomposition islands ranged from 6 to 1752 days. Some soil chemistry, including nitrate-N (NO 3 -N), ammonium-N (NH 4 -N), and dissolved inorganic carbon (DIC), peaked at early PMI values and their concentrations at 0-5cm returned to near control values over time likely due to translocation down the soil profile. Other soil chemistry, including dissolved organic carbon (DOC), dissolved organic nitrogen (DON), orthophosphate-P (PO 4 -P), sodium (Na + ), and potassium (K + ), remained higher than the control soil up to a PMI of 1752days postmortem. The body mass index (BMI) of the cadaver appeared to have some effect on the cadaver decomposition island chemistry. To estimate PMI using soil chemistry, backward, stepwise multiple regression analysis was used with PMI as the dependent variable and soil chemistry, body mass index (BMI) and physical soil characteristics such as saturated hydraulic conductivity as independent variables. Measures of soil parameters derived from predator and microbial mediated decomposition of human remains shows promise in estimating PMI to within 365days for a period up to nearly five years. This persistent change in soil chemistry extends the ability to estimate PMI beyond the traditionally utilized methods of entomology and taphonomy in support of medical-legal investigations, humanitarian recovery efforts, and criminal and civil cases. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Stereological study of developing glomerular forms during human fetal kidney development.

    PubMed

    Dakovic Bjelakovic, Marija; Vlajkovic, Slobodan; Petrovic, Aleksandar; Bjelakovic, Marko; Antic, Milorad

    2018-05-01

    Human fetal kidney development is a complex and stepwise process. The number, shape, size and distribution of glomeruli provide important information on kidney organization. The aim of this study was to quantify glomerular developing forms during human fetal kidney development using stereological methods. Kidney tissue specimens of 40 human fetuses with gestational ages ranging from 9 to 40 weeks were analyzed. Specimens were divided into eight groups based on gestational age, each corresponding to 1 lunar month. Stereological methods were used at the light microscopy level to estimate volume, surface and numerical density of the glomerular developing forms. During gestation, nephrogenesis continually advanced, and the number of nephrons increased. Volume, surface and numerical densities of vesicular forms and S-shaped bodies decreased gradually in parallel with gradual increases in estimated stereological parameters for vascularized glomeruli. Volume density and surface density of vascularized glomeruli increased gradually during fetal kidney development, and numerical density increased until the seventh lunar month. A relative decrease in vascularized glomeruli per unit volume of cortex occurred during the last 3 lunar months. Nephrogenesis began to taper off by 32 weeks and was completed by 36 weeks of gestation. The last sample in which we observed vesicles was from a fetus aged 32 weeks, and the last sample with S-shaped bodies was from a fetus aged 36 weeks. The present study is one of few quantitative studies conducted on human kidney development. Knowledge of normal human kidney morphogenesis during development could be important for future medical practice. Events occurring during fetal life may have significant consequences later in life.

  19. Body proportions in ancient Andeans from high and low altitudes.

    PubMed

    Weinstein, Karen J

    2005-11-01

    Living human populations from high altitudes in the Andes exhibit relatively short limbs compared with neighboring groups from lower elevations as adaptations to cold climates characteristic of high-altitude environments. This study compares relative limb lengths and proportions in pre-Contact human skeletons from different altitudes to test whether ecogeographic variation also existed in Andean prehistory. Maximum lengths of the humerus, radius, femur, and tibia, and femoral head breadth are measured in sex-specific groups of adult human skeletons (N = 346) from the central (n = 80) and the south-central (n = 123) Andean coasts, the Atacama Desert at 2,500 m (n = 102), and the southern Peruvian highlands at 2,000-3,800 m (n = 41). To test whether limb lengths vary with altitude, comparisons are made of intralimb proportions, limb lengths against body mass estimates derived from published equations, limb lengths against the geometric mean of all measurements, and principal component analysis. Intralimb proportions do not statistically differ between coastal groups and those from the Atacama Desert, whereas intralimb proportions are significantly shorter in the Peruvian highland sample. Overall body size and limb lengths relative to body size vary along an altitudinal gradient, with larger individuals from coastal environments and smaller individuals with relatively longer limbs for their size from higher elevations. Ecogeographic variation in relation to climate explains the variation in intralimb proportions, and dietary variation may explain the altitudinal cline in body size and limb lengths relative to body size. The potential effects of gene flow on variation in body proportions in Andean prehistory are also explored. Copyright 2005 Wiley-Liss, Inc

  20. Radiation dosimetry estimates of (18)F-alfatide II based on whole-body PET imaging of mice.

    PubMed

    Wang, Si-Yang; Bao, Xiao; Wang, Ming-Wei; Zhang, Yong-Ping; Zhang, Ying-Jian; Zhang, Jian-Ping

    2015-11-01

    We estimated the dosimetry of (18)F-alfatide II with the method established by MIRD based on biodistribution data of mice. Six mice (three females and three males) were scanned for 160min on an Inveon MicroPET/CT scanner after injection of (18)F-alfatide II via tail vein. Eight source organs were delineated on the CT images and their residence times calculated. The data was then converted to human using scaling factors based on organ and body weight. The absorbed doses for human and the resulting effective dose were computed by OLINDA 1.1 software. The highest absorbed doses was observed in urinary bladder wall (male 0.102mGy/MBq, female 0.147mGy/MBq); and the lowest one was detected in brain (male 0.0030mGy/MBq, female 0.0036). The total effective doses were 0.0127mSv/MBq for male and 0.0166 mSv/MBq for female, respectively. A 370-MBq injection of (18)F-alfatide II led to an estimated effective dose of 4.70mSv for male and 6.14mSv for female. The potential radiation burden associated with (18)F-alfatide II/PET imaging therefore is comparable to other PET examinations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Development of a sliding mode control model for quiet upright stance.

    PubMed

    Zhang, Hongbo; Nussbaum, Maury A; Agnew, Michael J

    2016-02-01

    Human upright stance appears maintained or controlled intermittently, through some combination of passive and active ankle torques, respectively representing intrinsic and contractile contributions of the ankle musculature. Several intermittent postural control models have been proposed, though it has been challenging to accurately represent actual kinematics and kinetics and to separately estimate passive and active ankle torque components. Here, a simplified single-segment, 2D (sagittal plane) sliding mode control model was developed for application to track kinematics and kinetics during upright stance. The model was implemented and evaluated using previous experimental data consisting of whole body angular kinematics and ankle torques. Tracking errors for the whole-body center-of-mass (COM) angle and angular velocity, as well as ankle torque, were all within ∼10% of experimental values, though tracking performance for COM angular acceleration was substantially poorer. The model also enabled separate estimates of the contributions of passive and active ankle torques, with overall contributions estimated here to be 96% and 4% of the total ankle torque, respectively. Such a model may have future utility in understanding human postural control, though additional work is needed, such as expanding the model to multiple segments and to three dimensions. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. A Self-Adaptive Capacitive Compensation Technique for Body Channel Communication.

    PubMed

    Mao, Jingna; Yang, Huazhong; Lian, Yong; Zhao, Bo

    2017-10-01

    In wireless body area network, capacitive-coupling body channel communication (CC-BCC) has the potential to attain better energy efficiency over conventional wireless communication schemes. The CC-BCC scheme utilizes the human body as the forward signal transmission medium, reducing the path loss in wireless body-centric communications. However, the backward path is formed by the coupling capacitance between the ground electrodes (GEs) of transmitter (Tx) and receiver (Rx), which increases the path loss and results in a body posture dependent backward impedance. Conventional methods use a fixed inductor to resonate with the backward capacitor to compensate the path loss, while it's not effective in compensating the variable backward impedance induced by the body movements. In this paper, we propose a self-adaptive capacitive compensation (SACC) technique to address such a problem. A backward distance detector is introduced to estimate the distance between two GEs of Tx and Rx, and a backward capacitance model is built to calculate the backward capacitance. The calculated backward capacitance at varying body posture is compensated by a digitally controlled tunable inductor (DCTI). The proposed SACC technique is validated by a prototype CC-BCC system, and measurements are taken on human subjects. The measurement results show that 9dB-16 dB channel enhancement can be achieved at a backward path distance of 1 cm-10 cm.

  3. A Novel Kalman Filter for Human Motion Tracking With an Inertial-Based Dynamic Inclinometer.

    PubMed

    Ligorio, Gabriele; Sabatini, Angelo M

    2015-08-01

    Design and development of a linear Kalman filter to create an inertial-based inclinometer targeted to dynamic conditions of motion. The estimation of the body attitude (i.e., the inclination with respect to the vertical) was treated as a source separation problem to discriminate the gravity and the body acceleration from the specific force measured by a triaxial accelerometer. The sensor fusion between triaxial gyroscope and triaxial accelerometer data was performed using a linear Kalman filter. Wrist-worn inertial measurement unit data from ten participants were acquired while performing two dynamic tasks: 60-s sequence of seven manual activities and 90 s of walking at natural speed. Stereophotogrammetric data were used as a reference. A statistical analysis was performed to assess the significance of the accuracy improvement over state-of-the-art approaches. The proposed method achieved, on an average, a root mean square attitude error of 3.6° and 1.8° in manual activities and locomotion tasks (respectively). The statistical analysis showed that, when compared to few competing methods, the proposed method improved the attitude estimation accuracy. A novel Kalman filter for inertial-based attitude estimation was presented in this study. A significant accuracy improvement was achieved over state-of-the-art approaches, due to a filter design that better matched the basic optimality assumptions of Kalman filtering. Human motion tracking is the main application field of the proposed method. Accurately discriminating the two components present in the triaxial accelerometer signal is well suited for studying both the rotational and the linear body kinematics.

  4. An Assessment of the Exposure of Americans to Perflourooctane Sulfonate: A Comparison of Estimated Intake with Values Inferred from NHANES Data

    EPA Science Inventory

    To better understand human exposure to perfluorinated compounds (PFCs), a model that assesses exposure to perfluorooctane sulfonate (PFOS) and its precursors from both an intake and a body burden perspective and combines the two with a simple pharmacokinetic (PK) model is demonst...

  5. Estimating Anthropometric Marker Locations from 3-D LADAR Point Clouds

    DTIC Science & Technology

    2011-06-01

    http://perception.inrialpes. fr/Publications/2008/CMKBH08. [17] Da Vinci , L. The Notebooks of Leonardo Da Vinci Complete. Public Domain, 2004. [18] Duda...the problem is based on historical research into the proper proportioning of the human body. A famous example of this research is Leonardo da Vinci’s

  6. Development of Human Posture Simulation Method for Assessing Posture Angles and Spinal Loads

    PubMed Central

    Lu, Ming-Lun; Waters, Thomas; Werren, Dwight

    2015-01-01

    Video-based posture analysis employing a biomechanical model is gaining a growing popularity for ergonomic assessments. A human posture simulation method of estimating multiple body postural angles and spinal loads from a video record was developed to expedite ergonomic assessments. The method was evaluated by a repeated measures study design with three trunk flexion levels, two lift asymmetry levels, three viewing angles and three trial repetitions as experimental factors. The study comprised two phases evaluating the accuracy of simulating self and other people’s lifting posture via a proxy of a computer-generated humanoid. The mean values of the accuracy of simulating self and humanoid postures were 12° and 15°, respectively. The repeatability of the method for the same lifting condition was excellent (~2°). The least simulation error was associated with side viewing angle. The estimated back compressive force and moment, calculated by a three dimensional biomechanical model, exhibited a range of 5% underestimation. The posture simulation method enables researchers to simultaneously quantify body posture angles and spinal loading variables with accuracy and precision comparable to on-screen posture matching methods. PMID:26361435

  7. The volume of the human knee joint.

    PubMed

    Matziolis, Georg; Roehner, Eric; Windisch, Christoph; Wagner, Andreas

    2015-10-01

    Despite its clinical relevance, particularly in septic knee surgery, the volume of the human knee joint has not been established to date. Therefore, the objective of this study was to determine knee joint volume and whether or not it is dependent on sex or body height. Sixty-one consecutive patients (joints) who were due to undergo endoprosthetic joint replacement were enrolled in this prospective study. During the operation, the joint volume was determined by injecting saline solution until a pressure of 200 mmHg was achieved in the joint. The average volume of all knee joints was 131 ± 53 (40-290) ml. The volume was not found to be dependent on sex, but it was dependent on the patients' height (R = 0.312, p = 0.014). This enabled an estimation of the joint volume according to V = 1.6 height - 135. The considerable inter-individual variance of the knee joint volume would suggest that it should be determined or at least estimated according to body height if the joint volume has consequences for the diagnostics or therapy of knee disorders.

  8. Comparison of Human and Humanoid Robot Control of Upright Stance

    PubMed Central

    Peterka, Robert J.

    2009-01-01

    There is considerable recent interest in developing humanoid robots. An important substrate for many motor actions in both humans and biped robots is the ability to maintain a statically or dynamically stable posture. Given the success of the human design, one would expect there are lessons to be learned in formulating a postural control mechanism for robots. In this study we limit ourselves to considering the problem of maintaining upright stance. Human stance control is compared to a suggested method for robot stance control called zero moment point (ZMP) compensation. Results from experimental and modeling studies suggest there are two important subsystems that account for the low- and mid-frequency (DC to ~1 Hz) dynamic characteristics of human stance control. These subsystems are 1) a “sensory integration” mechanism whereby orientation information from multiple sensory systems encoding body kinematics (i.e. position, velocity) is flexibly combined to provide an overall estimate of body orientation while allowing adjustments (sensory re-weighting) that compensate for changing environmental conditions, and 2) an “effort control” mechanism that uses kinetic-related (i.e., force-related) sensory information to reduce the mean deviation of body orientation from upright. Functionally, ZMP compensation is directly analogous to how humans appear to use kinetic feedback to modify the main sensory integration feedback loop controlling body orientation. However, a flexible sensory integration mechanism is missing from robot control leaving the robot vulnerable to instability in conditions were humans are able to maintain stance. We suggest the addition of a simple form of sensory integration to improve robot stance control. We also investigate how the biological constraint of feedback time delay influences the human stance control design. The human system may serve as a guide for improved robot control, but should not be directly copied because the constraints on robot and human control are different. PMID:19665564

  9. Comparison of human and humanoid robot control of upright stance.

    PubMed

    Peterka, Robert J

    2009-01-01

    There is considerable recent interest in developing humanoid robots. An important substrate for many motor actions in both humans and biped robots is the ability to maintain a statically or dynamically stable posture. Given the success of the human design, one would expect there are lessons to be learned in formulating a postural control mechanism for robots. In this study we limit ourselves to considering the problem of maintaining upright stance. Human stance control is compared to a suggested method for robot stance control called zero moment point (ZMP) compensation. Results from experimental and modeling studies suggest there are two important subsystems that account for the low- and mid-frequency (DC to approximately 1Hz) dynamic characteristics of human stance control. These subsystems are (1) a "sensory integration" mechanism whereby orientation information from multiple sensory systems encoding body kinematics (i.e. position, velocity) is flexibly combined to provide an overall estimate of body orientation while allowing adjustments (sensory re-weighting) that compensate for changing environmental conditions and (2) an "effort control" mechanism that uses kinetic-related (i.e., force-related) sensory information to reduce the mean deviation of body orientation from upright. Functionally, ZMP compensation is directly analogous to how humans appear to use kinetic feedback to modify the main sensory integration feedback loop controlling body orientation. However, a flexible sensory integration mechanism is missing from robot control leaving the robot vulnerable to instability in conditions where humans are able to maintain stance. We suggest the addition of a simple form of sensory integration to improve robot stance control. We also investigate how the biological constraint of feedback time delay influences the human stance control design. The human system may serve as a guide for improved robot control, but should not be directly copied because the constraints on robot and human control are different.

  10. A Markerless 3D Computerized Motion Capture System Incorporating a Skeleton Model for Monkeys.

    PubMed

    Nakamura, Tomoya; Matsumoto, Jumpei; Nishimaru, Hiroshi; Bretas, Rafael Vieira; Takamura, Yusaku; Hori, Etsuro; Ono, Taketoshi; Nishijo, Hisao

    2016-01-01

    In this study, we propose a novel markerless motion capture system (MCS) for monkeys, in which 3D surface images of monkeys were reconstructed by integrating data from four depth cameras, and a skeleton model of the monkey was fitted onto 3D images of monkeys in each frame of the video. To validate the MCS, first, estimated 3D positions of body parts were compared between the 3D MCS-assisted estimation and manual estimation based on visual inspection when a monkey performed a shuttling behavior in which it had to avoid obstacles in various positions. The mean estimation error of the positions of body parts (3-14 cm) and of head rotation (35-43°) between the 3D MCS-assisted and manual estimation were comparable to the errors between two different experimenters performing manual estimation. Furthermore, the MCS could identify specific monkey actions, and there was no false positive nor false negative detection of actions compared with those in manual estimation. Second, to check the reproducibility of MCS-assisted estimation, the same analyses of the above experiments were repeated by a different user. The estimation errors of positions of most body parts between the two experimenters were significantly smaller in the MCS-assisted estimation than in the manual estimation. Third, effects of methamphetamine (MAP) administration on the spontaneous behaviors of four monkeys were analyzed using the MCS. MAP significantly increased head movements, tended to decrease locomotion speed, and had no significant effect on total path length. The results were comparable to previous human clinical data. Furthermore, estimated data following MAP injection (total path length, walking speed, and speed of head rotation) correlated significantly between the two experimenters in the MCS-assisted estimation (r = 0.863 to 0.999). The results suggest that the presented MCS in monkeys is useful in investigating neural mechanisms underlying various psychiatric disorders and developing pharmacological interventions.

  11. Simple formula for the surface area of the body and a simple model for anthropometry.

    PubMed

    Reading, Bruce D; Freeman, Brian

    2005-03-01

    The body surface area (BSA) of any adult, when derived from the arithmetic mean of the different values calculated from four independent accepted formulae, can be expressed accurately in Systeme International d'Unites (SI) units by the simple equation BSA = 1/6(WH)0.5, where W is body weight in kg, H is body height in m, and BSA is in m2. This formula, which is derived in part by modeling the body as a simple solid of revolution or a prolate spheroid (i.e., a stretched ellipsoid of revolution) gives students, teachers, and clinicians a simple rule for the rapid estimation of surface area using rational units. The formula was tested independently for human subjects by using it to predict body volume and then comparing this prediction against the actual volume measured by Archimedes' principle. Copyright 2005 Wiley-Liss, Inc.

  12. Quantifying annual internal effective 137Cesium dose utilizing direct body-burden measurement and ecological dose modeling.

    PubMed

    Jelin, Benjamin A; Sun, Wenjie; Kravets, Alexandra; Naboka, Maryna; Stepanova, Eugenia I; Vdovenko, Vitaliy Y; Karmaus, Wilfried J; Lichosherstov, Alex; Svendsen, Erik R

    2016-11-01

    The Chernobyl Nuclear Power Plant (CNPP) accident represents one of the most significant civilian releases of 137 Cesium ( 137 Cs, radiocesium) in human history. In the Chernobyl-affected region, radiocesium is considered to be the greatest on-going environmental hazard to human health by radiobiologists and public health scientists. The goal of this study was to characterize dosimetric patterns and predictive factors for whole-body count (WBC)-derived radiocesium internal dose estimations in a CNPP-affected children's cohort, and cross-validate these estimations with a soil-based ecological dose estimation model. WBC data were used to estimate the internal effective dose using the International Commission on Radiological Protection (ICRP) 67 dose conversion coefficient for 137 Cs and MONDAL Version 3.01 software. Geometric mean dose estimates from each model were compared utilizing paired t-tests and intra-class correlation coefficients. Additionally, we developed predictive models for WBC-derived dose estimation in order to determine the appropriateness of EMARC to estimate dose for this population. The two WBC-derived dose predictive models identified 137 Cs soil concentration (P<0.0001) as the strongest predictor of annual internal effective dose from radiocesium validating the use of the soil-based EMARC model. The geometric mean internal effective dose estimate of the EMARC model (0.183 mSv/y) was the highest followed by the ICRP 67 dose estimates (0.165 mSv/y) and the MONDAL model estimates (0.149 mSv/y). All three models yielded significantly different geometric mean dose (P<0.05) estimates for this cohort when stratified by sex, age at time of exam and season of exam, except for the mean MONDAL and EMARC estimates for 15- and 16-year olds and mean ICRP and MONDAL estimates for children examined in Winter. Further prospective and retrospective radio-epidemiological studies utilizing refined WBC measurements and ecological model dose estimations, in conjunction with findings from animal toxicological studies, should help elucidate possible deterministic radiogenic health effects associated with chronic low-dose internal exposure to 137 Cs.

  13. Fixation patterns, not clinical diagnosis, predict body size over-estimation in eating disordered women and healthy controls.

    PubMed

    Cornelissen, Katri K; Cornelissen, Piers L; Hancock, Peter J B; Tovée, Martin J

    2016-05-01

    A core feature of anorexia nervosa (AN) is an over-estimation of body size. Women with AN have a different pattern of eye-movements when judging bodies, but it is unclear whether this is specific to their diagnosis or whether it is found in anyone over-estimating body size. To address this question, we compared the eye movement patterns from three participant groups while they carried out a body size estimation task: (i) 20 women with recovering/recovered anorexia (rAN) who had concerns about body shape and weight and who over-estimated body size, (ii) 20 healthy controls who had normative levels of concern about body shape and who estimated body size accurately (iii) 20 healthy controls who had normative levels of concern about body shape but who did over-estimate body size. Comparisons between the three groups showed that: (i) accurate body size estimators tended to look more in the waist region, and this was independent of clinical diagnosis; (ii) there is a pattern of looking at images of bodies, particularly viewing the upper parts of the torso and face, which is specific to participants with rAN but which is independent of accuracy in body size estimation. Since the over-estimating controls did not share the same body image concerns that women with rAN report, their over-estimation cannot be explained by attitudinal concerns about body shape and weight. These results suggest that a distributed fixation pattern is associated with over-estimation of body size and should be addressed in treatment programs. © 2016 Wiley Periodicals, Inc. (Int J Eat Disord 2016; 49:507-518). © 2016 The Authors. International Journal of Eating Disorders published by Wiley Periodicals, Inc.

  14. Adaptations in humans for assessing physical strength from the voice

    PubMed Central

    Sell, Aaron; Bryant, Gregory A.; Cosmides, Leda; Tooby, John; Sznycer, Daniel; von Rueden, Christopher; Krauss, Andre; Gurven, Michael

    2010-01-01

    Recent research has shown that humans, like many other animals, have a specialization for assessing fighting ability from visual cues. Because it is probable that the voice contains cues of strength and formidability that are not available visually, we predicted that selection has also equipped humans with the ability to estimate physical strength from the voice. We found that subjects accurately assessed upper-body strength in voices taken from eight samples across four distinct populations and language groups: the Tsimane of Bolivia, Andean herder-horticulturalists and United States and Romanian college students. Regardless of whether raters were told to assess height, weight, strength or fighting ability, they produced similar ratings that tracked upper-body strength independent of height and weight. Male voices were more accurately assessed than female voices, which is consistent with ethnographic data showing a greater tendency among males to engage in violent aggression. Raters extracted information about strength from the voice that was not supplied from visual cues, and were accurate with both familiar and unfamiliar languages. These results provide, to our knowledge, the first direct evidence that both men and women can accurately assess men's physical strength from the voice, and suggest that estimates of strength are used to assess fighting ability. PMID:20554544

  15. Body Composition Assessment in Axial CT Images Using FEM-Based Automatic Segmentation of Skeletal Muscle.

    PubMed

    Popuri, Karteek; Cobzas, Dana; Esfandiari, Nina; Baracos, Vickie; Jägersand, Martin

    2016-02-01

    The proportions of muscle and fat tissues in the human body, referred to as body composition is a vital measurement for cancer patients. Body composition has been recently linked to patient survival and the onset/recurrence of several types of cancers in numerous cancer research studies. This paper introduces a fully automatic framework for the segmentation of muscle and fat tissues from CT images to estimate body composition. We developed a novel finite element method (FEM) deformable model that incorporates a priori shape information via a statistical deformation model (SDM) within the template-based segmentation framework. The proposed method was validated on 1000 abdominal and 530 thoracic CT images and we obtained very good segmentation results with Jaccard scores in excess of 90% for both the muscle and fat regions.

  16. The timing of the human circadian clock is accurately represented by the core body temperature rhythm following phase shifts to a three-cycle light stimulus near the critical zone

    NASA Technical Reports Server (NTRS)

    Jewett, M. E.; Duffy, J. F.; Czeisler, C. A.

    2000-01-01

    A double-stimulus experiment was conducted to evaluate the phase of the underlying circadian clock following light-induced phase shifts of the human circadian system. Circadian phase was assayed by constant routine from the rhythm in core body temperature before and after a three-cycle bright-light stimulus applied near the estimated minimum of the core body temperature rhythm. An identical, consecutive three-cycle light stimulus was then applied, and phase was reassessed. Phase shifts to these consecutive stimuli were no different from those obtained in a previous study following light stimuli applied under steady-state conditions over a range of circadian phases similar to those at which the consecutive stimuli were applied. These data suggest that circadian phase shifts of the core body temperature rhythm in response to a three-cycle stimulus occur within 24 h following the end of the 3-day light stimulus and that this poststimulus temperature rhythm accurately reflects the timing of the underlying circadian clock.

  17. Emerging and legacy flame retardants in UK human milk and food suggest slow response to restrictions on use of PBDEs and HBCDD.

    PubMed

    Tao, Fang; Abou-Elwafa Abdallah, Mohamed; Ashworth, Danielle C; Douglas, Philippa; Toledano, Mireille B; Harrad, Stuart

    2017-08-01

    The legacy flame retardants (LFRs) polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCDD), together with six emerging flame retardants (EFRs) were measured in United Kingdom (UK) human milk collected in 2010 (n=25) and 2014-15 (n=10). These data are the first report of the presence of EFRs in UK human milk. The most abundant EFR was β-tetrabromoethylcyclohexane (DBE-DBCH) (average=2.5ng/g lw; geometric mean=1.5ng/g lw), which is comparable to the concentrations of the most abundant LFRs i.e. BDE 47 and α-HBCDD at 2.8 and 2.1ng/g lw, respectively (geometric mean=2.1 and 1.7). The estimated median dietary intake of ΣEFRs by UK nursing infants was 18ng/kg bw/day. EFRs were also measured in UK foodstuffs with β-DBE-DBCH again the predominant compound detected, accounting - on average - for 64.5±23.4% of ΣEFRs. Average estimated dietary intakes of ∑EFRs in the UK were 89 and 26ng/day (1.3 and 2.6ng/body weight/day) for adults and toddlers, respectively. Concentrations of Σtri-hexa BDEs in our UK food samples exceeded those reported in UK samples from the same food categories collected in 2003-04 and 2006. Despite this and our recent report elsewhere of significant temporal declines in concentrations of BDE 209 in UK indoor dust (p<0.05) and HBCDDs in UK indoor dust and air (p<0.001), no significant temporal differences (p>0.05) were observed between concentrations of Σtri-hexa BDEs, BDE 209 and HBCDDs in human milk sampled in 2010 and those obtained in 2014-15. UK adult body burdens for EFRs were predicted via inhalation, diet and dust ingestion using a simple pharmacokinetic model. The predicted EFR body burdens compared well with observed concentrations in human milk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. SERS quantitative urine creatinine measurement of human subject

    NASA Astrophysics Data System (ADS)

    Wang, Tsuei Lian; Chiang, Hui-hua K.; Lu, Hui-hsin; Hung, Yung-da

    2005-03-01

    SERS method for biomolecular analysis has several potentials and advantages over traditional biochemical approaches, including less specimen contact, non-destructive to specimen, and multiple components analysis. Urine is an easily available body fluid for monitoring the metabolites and renal function of human body. We developed surface-enhanced Raman scattering (SERS) technique using 50nm size gold colloidal particles for quantitative human urine creatinine measurements. This paper shows that SERS shifts of creatinine (104mg/dl) in artificial urine is from 1400cm-1 to 1500cm-1 which was analyzed for quantitative creatinine measurement. Ten human urine samples were obtained from ten healthy persons and analyzed by the SERS technique. Partial least square cross-validation (PLSCV) method was utilized to obtain the estimated creatinine concentration in clinically relevant (55.9mg/dl to 208mg/dl) concentration range. The root-mean square error of cross validation (RMSECV) is 26.1mg/dl. This research demonstrates the feasibility of using SERS for human subject urine creatinine detection, and establishes the SERS platform technique for bodily fluids measurement.

  19. Predicting metabolic adaptation, body weight change, and energy intake in humans

    PubMed Central

    2010-01-01

    Complex interactions between carbohydrate, fat, and protein metabolism underlie the body's remarkable ability to adapt to a variety of diets. But any imbalances between the intake and utilization rates of these macronutrients will result in changes in body weight and composition. Here, I present the first computational model that simulates how diet perturbations result in adaptations of fuel selection and energy expenditure that predict body weight and composition changes in both obese and nonobese men and women. No model parameters were adjusted to fit these data other than the initial conditions for each subject group (e.g., initial body weight and body fat mass). The model provides the first realistic simulations of how diet perturbations result in adaptations of whole body energy expenditure, fuel selection, and various metabolic fluxes that ultimately give rise to body weight change. The validated model was used to estimate free-living energy intake during a long-term weight loss intervention, a variable that has never previously been measured accurately. PMID:19934407

  20. Human body area factors for radiation exchange analysis: standing and walking postures

    NASA Astrophysics Data System (ADS)

    Park, Sookuk; Tuller, Stanton E.

    2011-09-01

    Effective radiation area factors ( f eff) and projected area factors ( f p) of unclothed Caucasians' standing and walking postures used in estimating human radiation exchange with the surrounding environment were determined from a sample of adults in Canada. Several three-dimensional (3D) computer body models were created for standing and walking postures. Only small differences in f eff and f p values for standing posture were found between gender (male or female) and body type (normal- or over-weight). Differences between this study and previous studies were much larger: ≤0.173 in f p and ≤0.101 in f eff. Directionless f p values for walking posture also had only minor differences between genders and positions in a stride. However, the differences of mean directional f p values of the positions dependent on azimuth angles were large enough, ≤0.072, to create important differences in modeled radiation receipt. Differences in f eff values were small: 0.02 between the normal-weight male and female models and up to 0.033 between positions in a stride. Variations of directional f p values depending on solar altitudes for walking posture were narrower than those for standing posture. When both standing and walking postures are considered, the mean f eff value, 0.836, of standing (0.826) and walking (0.846) could be used. However, f p values should be selected carefully because differences between directional and directionless f p values were large enough that they could influence the estimated level of human thermal sensation.

  1. Pre-anthropocene mercury residues in North American freshwater fish.

    PubMed

    Hope, Bruce K; Louch, Jeff

    2014-04-01

    Mercury (Hg) has been entering the environment from both natural and anthropogenic sources for millennia, and humans have been influencing its environmental transport and fate from well before the Industrial Revolution. Exposure to Hg (as neurotoxic monomethylmercury [MeHg]) occurs primarily through consumption of finfish, shellfish, and marine mammals, and regulatory limits for MeHg concentrations in fish tissue have steadily decreased as information on its health impacts has become available. These facts prompted us to consider 2 questions: 1) What might the MeHg levels in fish tissue have been in the pre-Anthropocene, before significant human impacts on the environment? and 2) How would these pre-Anthropocene levels have compared with current regulatory criteria for MeHg residues in fish tissue? We addressed the first question by estimating pre-Anthropocene concentrations of MeHg in the tissues of prey and predatory fish with an integrated Hg speciation, transport, fate, and food web model (SERAFM), using estimated Hg concentrations in soil, sediment, and atmospheric deposition before the onset of significant human activity (i.e., ≤2000 BCE). Model results show MeHg residues in fish varying depending on the characteristics of the modeled water body, which suggests that Hg in fish tissue is best considered at the scale of individual watersheds or water bodies. We addressed the second question by comparing these model estimates with current regulatory criteria and found that MeHg residues in predatory (but not prey) fish could have approached or exceeded these criteria in some water bodies during the pre-Anthropocene. This suggests that the possibility of naturally occurring levels of Hg in fish below which it is not possible to descend, regardless of where those levels stand with respect to current regulatory limits. Risk management decisions made under these circumstances have the potential to be ineffectual, frustrating, and costly for decision makers and stakeholders alike, suggesting the need for regulatory flexibility when addressing the issue of Hg in fish. © 2013 SETAC.

  2. Multifactorial analysis of human blood cell responses to clinical total body irradiation

    NASA Technical Reports Server (NTRS)

    Yuhas, J. M.; Stokes, T. R.; Lushbaugh, C. C.

    1972-01-01

    Multiple regression analysis techniques are used to study the effects of therapeutic radiation exposure, number of fractions, and time on such quantal responses as tumor control and skin injury. The potential of these methods for the analysis of human blood cell responses is demonstrated and estimates are given of the effects of total amount of exposure and time of protraction in determining the minimum white blood cell concentration observed after exposure of patients from four disease groups.

  3. Proposed biokinetic model for phosphorus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne

    2014-06-04

    This paper reviews data related to the biokinetics of phosphorus in the human body and proposes a biokinetic model for systemic phosphorus for use in updated International Commission on Radiological Protection (ICRP) guidance on occupational intake of radionuclides. Compared with the ICRP s current occupational model for phosphorus (Publication 68, 1994) the proposed model provides a more realistic description of the paths of movement of phosphorus in the body and improved consistency with experimental, medical, and environmental data on the time-dependent distribution and retention of phosphorus following uptake to blood. For acute uptake of 32P to blood, the proposed modelmore » yields roughly a 50% decrease in dose estimates for bone surface and red marrow and a 6-fold increase in estimates for liver and kidney compared with the biokinetic model of Publication 68 (applying Publication 68 dosimetric models in both sets of calculations). For acute uptake of 33P to blood, the proposed model yields roughly a 50% increase in dose estimates for bone surface and red marrow and a 7-fold increase in estimates for liver and kidney compared with the model of Publication 68.« less

  4. Estimation of median human lethal radiation dose computed from data on occupants of reinforced concrete structures in Nagasaki, Japan.

    PubMed

    Levin, S G; Young, R W; Stohler, R L

    1992-11-01

    This paper presents an estimate of the median lethal dose for humans exposed to total-body irradiation and not subsequently treated for radiation sickness. The median lethal dose was estimated from calculated doses to young adults who were inside two reinforced concrete buildings that remained standing in Nagasaki after the atomic detonation. The individuals in this study, none of whom have previously had calculated doses, were identified from a detailed survey done previously. Radiation dose to the bone marrow, which was taken as the critical radiation site, was calculated for each individual by the Engineering Physics and Mathematics Division of the Oak Ridge National Laboratory using a new three-dimensional discrete-ordinates radiation transport code that was developed and validated for this study using the latest site geometry, radiation yield, and spectra data. The study cohort consisted of 75 individuals who either survived > 60 d or died between the second and 60th d postirradiation due to radiation injury, without burns or other serious injury. Median lethal dose estimates were calculated using both logarithmic (2.9 Gy) and linear (3.4 Gy) dose scales. Both calculations, which met statistical validity tests, support previous estimates of the median lethal dose based solely on human data, which cluster around 3 Gy.

  5. Modified wind chill temperatures determined by a whole body thermoregulation model and human-based facial convective coefficients.

    PubMed

    Shabat, Yael Ben; Shitzer, Avraham; Fiala, Dusan

    2014-08-01

    Wind chill equivalent temperatures (WCETs) were estimated by a modified Fiala's whole body thermoregulation model of a clothed person. Facial convective heat exchange coefficients applied in the computations concurrently with environmental radiation effects were taken from a recently derived human-based correlation. Apart from these, the analysis followed the methodology used in the derivation of the currently used wind chill charts. WCET values are summarized by the following equation:[Formula: see text]Results indicate consistently lower estimated facial skin temperatures and consequently higher WCETs than those listed in the literature and used by the North American weather services. Calculated dynamic facial skin temperatures were additionally applied in the estimation of probabilities for the occurrence of risks of frostbite. Predicted weather combinations for probabilities of "Practically no risk of frostbite for most people," for less than 5 % risk at wind speeds above 40 km h(-1), were shown to occur at air temperatures above -10 °C compared to the currently published air temperature of -15 °C. At air temperatures below -35 °C, the presently calculated weather combination of 40 km h(-1)/-35 °C, at which the transition for risks to incur a frostbite in less than 2 min, is less conservative than that published: 60 km h(-1)/-40 °C. The present results introduce a fundamentally improved scientific basis for estimating facial skin temperatures, wind chill temperatures and risk probabilities for frostbites over those currently practiced.

  6. Modified wind chill temperatures determined by a whole body thermoregulation model and human-based facial convective coefficients

    NASA Astrophysics Data System (ADS)

    Shabat, Yael Ben; Shitzer, Avraham; Fiala, Dusan

    2014-08-01

    Wind chill equivalent temperatures (WCETs) were estimated by a modified Fiala's whole body thermoregulation model of a clothed person. Facial convective heat exchange coefficients applied in the computations concurrently with environmental radiation effects were taken from a recently derived human-based correlation. Apart from these, the analysis followed the methodology used in the derivation of the currently used wind chill charts. WCET values are summarized by the following equation: Results indicate consistently lower estimated facial skin temperatures and consequently higher WCETs than those listed in the literature and used by the North American weather services. Calculated dynamic facial skin temperatures were additionally applied in the estimation of probabilities for the occurrence of risks of frostbite. Predicted weather combinations for probabilities of "Practically no risk of frostbite for most people," for less than 5 % risk at wind speeds above 40 km h-1, were shown to occur at air temperatures above -10 °C compared to the currently published air temperature of -15 °C. At air temperatures below -35 °C, the presently calculated weather combination of 40 km h-1/-35 °C, at which the transition for risks to incur a frostbite in less than 2 min, is less conservative than that published: 60 km h-1/-40 °C. The present results introduce a fundamentally improved scientific basis for estimating facial skin temperatures, wind chill temperatures and risk probabilities for frostbites over those currently practiced.

  7. City-scale expansion of human thermoregulatory costs.

    PubMed

    Hill, Richard W; Muhich, Timothy E; Humphries, Murray M

    2013-01-01

    The physiological maintenance of a stable internal temperature by mammals and birds - the phenomenon termed homeothermy - is well known to be energetically expensive. The annual energy requirements of free-living mammals and birds are estimated to be 15-30 times higher than those of similar-size ectothermic vertebrates like lizards. Contemporary humans also use energy to accomplish thermoregulation. They are unique, however, in having shifted thermoregulatory control from the body to the occupied environment, with most people living in cities in dwellings that are temperature-regulated by furnaces and air conditioners powered by exogenous energy sources. The energetic implications of this strategy remain poorly defined. Here we comparatively quantify energy costs in cities, dwellings, and individual human bodies. Thermoregulation persists as a major driver of energy expenditure across these three scales, resulting in energy-versus-ambient-temperature relationships remarkably similar in shape. Incredibly, despite the many and diversified uses of network-delivered energy in modern societies, the energy requirements of six North American cities are as temperature-dependent as the energy requirements of isolated, individual homeotherms. However, the annual per-person energy cost of exogenously powered thermoregulation in cities and dwellings is 9-28 times higher than the cost of endogenous, metabolic thermoregulation of the human body. Shifting the locus of thermoregulatory control from the body to the dwelling achieves climate-independent thermal comfort. However, in an era of amplifying climate change driven by the carbon footprint of humanity, we must acknowledge the energetic extravagance of contemporary, city-scale thermoregulation, which prioritizes heat production over heat conservation.

  8. City-Scale Expansion of Human Thermoregulatory Costs

    PubMed Central

    Hill, Richard W.; Muhich, Timothy E.; Humphries, Murray M.

    2013-01-01

    The physiological maintenance of a stable internal temperature by mammals and birds – the phenomenon termed homeothermy – is well known to be energetically expensive. The annual energy requirements of free-living mammals and birds are estimated to be 15–30 times higher than those of similar-size ectothermic vertebrates like lizards. Contemporary humans also use energy to accomplish thermoregulation. They are unique, however, in having shifted thermoregulatory control from the body to the occupied environment, with most people living in cities in dwellings that are temperature-regulated by furnaces and air conditioners powered by exogenous energy sources. The energetic implications of this strategy remain poorly defined. Here we comparatively quantify energy costs in cities, dwellings, and individual human bodies. Thermoregulation persists as a major driver of energy expenditure across these three scales, resulting in energy-versus-ambient-temperature relationships remarkably similar in shape. Incredibly, despite the many and diversified uses of network-delivered energy in modern societies, the energy requirements of six North American cities are as temperature-dependent as the energy requirements of isolated, individual homeotherms. However, the annual per-person energy cost of exogenously powered thermoregulation in cities and dwellings is 9–28 times higher than the cost of endogenous, metabolic thermoregulation of the human body. Shifting the locus of thermoregulatory control from the body to the dwelling achieves climate-independent thermal comfort. However, in an era of amplifying climate change driven by the carbon footprint of humanity, we must acknowledge the energetic extravagance of contemporary, city-scale thermoregulation, which prioritizes heat production over heat conservation. PMID:24143181

  9. Use of epidemiologic data in Integrated Risk Information System (IRIS) assessments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Persad, Amanda S.; Cooper, Glinda S.

    2008-11-15

    In human health risk assessment, information from epidemiologic studies is typically utilized in the hazard identification step of the risk assessment paradigm. However, in the assessment of many chemicals by the Integrated Risk Information System (IRIS), epidemiologic data, both observational and experimental, have also been used in the derivation of toxicological risk estimates (i.e., reference doses [RfD], reference concentrations [RfC], oral cancer slope factors [CSF] and inhalation unit risks [IUR]). Of the 545 health assessments posted on the IRIS database as of June 2007, 44 assessments derived non-cancer or cancer risk estimates based on human data. RfD and RfC calculationsmore » were based on a spectrum of endpoints from changes in enzyme activity to specific neurological or dermal effects. There are 12 assessments with IURs based on human data, two assessments that extrapolated human inhalation data to derive CSFs and one that used human data to directly derive a CSF. Lung or respiratory cancer is the most common endpoint for cancer assessments based on human data. To date, only one chemical, benzene, has utilized human data for derivation of all three quantitative risk estimates (i.e., RfC, RfD, and dose-response modeling for cancer assessment). Through examples from the IRIS database, this paper will demonstrate how epidemiologic data have been used in IRIS assessments for both adding to the body of evidence in the hazard identification process and in the quantification of risk estimates in the dose-response component of the risk assessment paradigm.« less

  10. Association between inaccurate estimation of body size and obesity in schoolchildren.

    PubMed

    Costa, Larissa da Cunha Feio; Silva, Diego Augusto Santos; Almeida, Sebastião de Sousa; de Vasconcelos, Francisco de Assis Guedes

    2015-01-01

    To investigate the prevalence of inaccurate estimation of own body size among Brazilian schoolchildren of both sexes aged 7-10 years, and to test whether overweight/obesity; excess body fat and central obesity are associated with inaccuracy. Accuracy of body size estimation was assessed using the Figure Rating Scale for Brazilian Children. Multinomial logistic regression was used to analyze associations. The overall prevalence of inaccurate body size estimation was 76%, with 34% of the children underestimating their body size and 42% overestimating their body size. Obesity measured by body mass index was associated with underestimation of body size in both sexes, while central obesity was only associated with overestimation of body size among girls. The results of this study suggest there is a high prevalence of inaccurate body size estimation and that inaccurate estimation is associated with obesity. Accurate estimation of own body size is important among obese schoolchildren because it may be the first step towards adopting healthy lifestyle behaviors.

  11. Using inertial measurement units to identify medio-lateral ground reaction forces due to walking and swaying

    NASA Astrophysics Data System (ADS)

    Brownjohn, James Mark William; Chen, Jun; Bocian, Mateusz; Racic, Vitomir; Shahabpoor, Erfan

    2018-07-01

    Horizontal ground reaction forces (GRFs) due to human walking and swaying have been investigated (respectively) through direct measurements using a treadmill and a set of force plates. These GRFs have also been measured (or estimated) indirectly using acceleration data provided by inertial measurement units (IMUs). One motivation for this research has been the lack of published data on these two forms of loading that are generated by movements of the human body in the medio-lateral plane perpendicular to the direction of walking or the direction faced during swaying. The other motivation, following from successful developments in applying IMUs to in-situ vertical GRF measurements, has been to identify best practice for estimating medio-lateral GRFs outside the constraints of a laboratory. Examination of 852 treadmill measurements shows that medio-lateral GRFs at the first sub-harmonic of pacing rate can exceed 10% of body weight. Using a smaller and more recent set of measurements including motion capture, it has been shown that IMUs can be used to reconstruct these GRFs using a linear combination of body accelerations at each of the lower back and sternum positions. There are a number of potential applications for this capability yet to be explored, in particular relating to footbridge performance. A separate set of measurements using force plates has shown that harmonic components of medio-lateral dynamic load factors due to on the spot swaying can approach 50% of body weight. Such forces provide a capability to excite horizontal vibration modes of large civil structures with frequencies below 2 Hz that are problematic for mechanical excitation. As with walking, the ability to use IMUs to estimate medio-lateral swaying GRFs outside laboratory constraints has been demonstrated. As for walking a pair of IMUs is needed, but the best linear combination varies strongly between individuals, according to swaying style. In-situ application of indirect measurement has been successfully demonstrated through a very challenging application of system identification of a multi-storey building, including estimation of modal mass.

  12. Retrospective determination of the contamination in the HML's counting chambers.

    PubMed

    Kramer, Gary H; Hauck, Barry; Capello, Kevin; Phan, Quoc

    2008-09-01

    The original documentation surrounding the purchase of the Human Monitoring Laboratory's (HML) counting chambers clearly showed that the steel contained low levels of radioactivity, presumably as a result of A-bomb fallout or perhaps to the inadvertent mixing of radioactive sources with scrap steel. Monte Carlo simulations have been combined with experimental measurements to estimate the level of contamination in the steel of the HML's whole body counting chamber. A 24-h empty chamber background count showed the presence of 137Cs and 60Co. The estimated activity of 137Cs in the 51 tons of steel was 2.7 kBq in 2007 (51.3 microBq g(-1) steel) which would have been 8 kBq at the time of manufacture. The 60Co that was found in the background spectrum is postulated to be contained in the bed-frame. The estimated amount in 2007 was 5 Bq and its origin is likely to be contaminated scrap metal entering the steel production cycle sometime in the past. The estimated activities are 10 to 25 times higher than the estimated minimum detectable activity for this measurement. These amounts have no impact on the usefulness of the whole body counter.

  13. In Vitro Studies Evaluating Leaching of Mercury from Mine Waste Calcine Using Simulated Human Body Fluids

    PubMed Central

    2010-01-01

    In vitro bioaccessibility (IVBA) studies were carried out on samples of mercury (Hg) mine-waste calcine (roasted Hg ore) by leaching with simulated human body fluids. The objective was to estimate potential human exposure to Hg due to inhalation of airborne calcine particulates and hand-to-mouth ingestion of Hg-bearing calcines. Mine waste calcines collected from Hg mines at Almadén, Spain, and Terlingua, Texas, contain Hg sulfide, elemental Hg, and soluble Hg compounds, which constitute primary ore or compounds formed during Hg retorting. Elevated leachate Hg concentrations were found during calcine leaching using a simulated gastric fluid (as much as 6200 μg of Hg leached/g sample). Elevated Hg concentrations were also found in calcine leachates using a simulated lung fluid (as much as 9200 μg of Hg leached/g), serum-based fluid (as much as 1600 μg of Hg leached/g), and water of pH 5 (as much as 880 μg of Hg leached/g). The leaching capacity of Hg is controlled by calcine mineralogy; thus, calcines containing soluble Hg compounds contain higher leachate Hg concentrations. Results indicate that ingestion or inhalation of Hg mine-waste calcine may lead to increased Hg concentrations in the human body, especially through the ingestion pathway. PMID:20491469

  14. In vitro studies evaluating leaching of mercury from mine waste calcine using simulated human body fluids.

    PubMed

    Gray, John E; Plumlee, Geoffrey S; Morman, Suzette A; Higueras, Pablo L; Crock, James G; Lowers, Heather A; Witten, Mark L

    2010-06-15

    In vitro bioaccessibility (IVBA) studies were carried out on samples of mercury (Hg) mine-waste calcine (roasted Hg ore) by leaching with simulated human body fluids. The objective was to estimate potential human exposure to Hg due to inhalation of airborne calcine particulates and hand-to-mouth ingestion of Hg-bearing calcines. Mine waste calcines collected from Hg mines at Almaden, Spain, and Terlingua, Texas, contain Hg sulfide, elemental Hg, and soluble Hg compounds, which constitute primary ore or compounds formed during Hg retorting. Elevated leachate Hg concentrations were found during calcine leaching using a simulated gastric fluid (as much as 6200 microg of Hg leached/g sample). Elevated Hg concentrations were also found in calcine leachates using a simulated lung fluid (as much as 9200 microg of Hg leached/g), serum-based fluid (as much as 1600 microg of Hg leached/g), and water of pH 5 (as much as 880 microg of Hg leached/g). The leaching capacity of Hg is controlled by calcine mineralogy; thus, calcines containing soluble Hg compounds contain higher leachate Hg concentrations. Results indicate that ingestion or inhalation of Hg mine-waste calcine may lead to increased Hg concentrations in the human body, especially through the ingestion pathway.

  15. In vitro studies evaluating leaching of mercury from mine waste calcine using simulated human body fluids

    USGS Publications Warehouse

    Gray, John E.; Plumlee, Geoffrey S.; Morman, Suzette A.; Higueras, Pablo L.; Crock, James G.; Lowers, Heather A.; Witten, Mark L.

    2010-01-01

    In vitro bioaccessibility (IVBA) studies were carried out on samples of mercury (Hg) mine-waste calcine (roasted Hg ore) by leaching with simulated human body fluids. The objective was to estimate potential human exposure to Hg due to inhalation of airborne calcine particulates and hand-to-mouth ingestion of Hg-bearing calcines. Mine waste calcines collected from Hg mines at Almadén, Spain, and Terlingua, Texas, contain Hg sulfide, elemental Hg, and soluble Hg compounds, which constitute primary ore or compounds formed during Hg retorting. Elevated leachate Hg concentrations were found during calcine leaching using a simulated gastric fluid (as much as 6200 μg of Hg leached/g sample). Elevated Hg concentrations were also found in calcine leachates using a simulated lung fluid (as much as 9200 μg of Hg leached/g), serum-based fluid (as much as 1600 μg of Hg leached/g), and water of pH 5 (as much as 880 μg of Hg leached/g). The leaching capacity of Hg is controlled by calcine mineralogy; thus, calcines containing soluble Hg compounds contain higher leachate Hg concentrations. Results indicate that ingestion or inhalation of Hg mine-waste calcine may lead to increased Hg concentrations in the human body, especially through the ingestion pathway.

  16. Compact DD generator based in vivo neutron activation analysis (IVNAA) system to determine sodium concentrations in human bone.

    PubMed

    Coyne, Mychaela Dawn; Neumann, Colby R; Zhang, Xinxin; Byrne, Patrick; Liu, Yingzi; Weaver, Connie M; Nie, Linda Huiling

    2018-04-16

    This study presents the development of a non-invasive method for monitoring Na in human bone. Many diseases, such as hypertension and osteoporosis, are closely associated with sodium (Na) retention in the human body. Na retention is generally evaluated by calculating the difference between dietary intake and excretion. There is currently no method to directly quantify Na retained in the body. Bone is a storage for many elements, including Na, which renders bone Na an ideal biomarker to study Na metabolism and retention. Approach: A customized compact deuterium-deuterium (DD) neutron generator was used to produce neutrons for in vivo neutron activation analysis (IVNAA), with a moderator/ reflector/ shielding assembly optimized for human hand irradiation in order to maximize the thermal neutron flux inside the irradiation cave and to limit radiation exposure to the hand and the whole body. Main Results: The experimental results show that the system is able to detect sodium levels in the bone as low as 12 g Na/g dry bone with an effective dose to the body of about 27 μSv. The simulation results agree with the numbers estimated from the experiment. Significance: This is expected to be a feasible method for measuring the change of Na in bone. The low detection limit indicates this will be a useful system to study the association between Na retention and related diseases. © 2018 Institute of Physics and Engineering in Medicine.

  17. Conditions that influence the accuracy of anthropometric parameter estimation for human body segments using shape-from-silhouette

    NASA Astrophysics Data System (ADS)

    Mundermann, Lars; Mundermann, Annegret; Chaudhari, Ajit M.; Andriacchi, Thomas P.

    2005-01-01

    Anthropometric parameters are fundamental for a wide variety of applications in biomechanics, anthropology, medicine and sports. Recent technological advancements provide methods for constructing 3D surfaces directly. Of these new technologies, visual hull construction may be the most cost-effective yet sufficiently accurate method. However, the conditions influencing the accuracy of anthropometric measurements based on visual hull reconstruction are unknown. The purpose of this study was to evaluate the conditions that influence the accuracy of 3D shape-from-silhouette reconstruction of body segments dependent on number of cameras, camera resolution and object contours. The results demonstrate that the visual hulls lacked accuracy in concave regions and narrow spaces, but setups with a high number of cameras reconstructed a human form with an average accuracy of 1.0 mm. In general, setups with less than 8 cameras yielded largely inaccurate visual hull constructions, while setups with 16 and more cameras provided good volume estimations. Body segment volumes were obtained with an average error of 10% at a 640x480 resolution using 8 cameras. Changes in resolution did not significantly affect the average error. However, substantial decreases in error were observed with increasing number of cameras (33.3% using 4 cameras; 10.5% using 8 cameras; 4.1% using 16 cameras; 1.2% using 64 cameras).

  18. A low-cost three-dimensional laser surface scanning approach for defining body segment parameters.

    PubMed

    Pandis, Petros; Bull, Anthony Mj

    2017-11-01

    Body segment parameters are used in many different applications in ergonomics as well as in dynamic modelling of the musculoskeletal system. Body segment parameters can be defined using different methods, including techniques that involve time-consuming manual measurements of the human body, used in conjunction with models or equations. In this study, a scanning technique for measuring subject-specific body segment parameters in an easy, fast, accurate and low-cost way was developed and validated. The scanner can obtain the body segment parameters in a single scanning operation, which takes between 8 and 10 s. The results obtained with the system show a standard deviation of 2.5% in volumetric measurements of the upper limb of a mannequin and 3.1% difference between scanning volume and actual volume. Finally, the maximum mean error for the moment of inertia by scanning a standard-sized homogeneous object was 2.2%. This study shows that a low-cost system can provide quick and accurate subject-specific body segment parameter estimates.

  19. Active numerical model of human body for reconstruction of falls from height.

    PubMed

    Milanowicz, Marcin; Kędzior, Krzysztof

    2017-01-01

    Falls from height constitute the largest group of incidents out of approximately 90,000 occupational accidents occurring each year in Poland. Reconstruction of the exact course of a fall from height is generally difficult due to lack of sufficient information from the accident scene. This usually results in several contradictory versions of an incident and impedes, for example, determination of the liability in a judicial process. In similar situations, in many areas of human activity, researchers apply numerical simulation. They use it to model physical phenomena to reconstruct their real course over time; e.g. numerical human body models are frequently used for investigation and reconstruction of road accidents. However, they are validated in terms of specific road traffic accidents and are considerably limited when applied to the reconstruction of other types of accidents. The objective of the study was to develop an active numerical human body model to be used for reconstruction of accidents associated with falling from height. Development of the model involved extension and adaptation of the existing Pedestrian human body model (available in the MADYMO package database) for the purposes of reconstruction of falls from height by taking into account the human reaction to the loss of balance. The model was developed by using the results of experimental tests of the initial phase of the fall from height. The active numerical human body model covering 28 sets of initial conditions related to various human reactions to the loss of balance was developed. The application of the model was illustrated by using it to reconstruct a real fall from height. From among the 28 sets of initial conditions, those whose application made it possible to reconstruct the most probable version of the incident was selected. The selection was based on comparison of the results of the reconstruction with information contained in the accident report. Results in the form of estimated injuries overlap with the real injuries sustained by the casualty. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Comparison of anthropometric-based equations for estimation of body fat percentage in a normal-weight and overweight female cohort: validation via air-displacement plethysmography.

    PubMed

    Temple, Derry; Denis, Romain; Walsh, Marianne C; Dicker, Patrick; Byrne, Annette T

    2015-02-01

    To evaluate the accuracy of the most commonly used anthropometric-based equations in the estimation of percentage body fat (%BF) in both normal-weight and overweight women using air-displacement plethysmography (ADP) as the criterion measure. A comparative study in which the equations of Durnin and Womersley (1974; DW) and Jackson, Pollock and Ward (1980) at three, four and seven sites (JPW₃, JPW₄ and JPW₇) were validated against ADP in three groups. Group 1 included all participants, group 2 included participants with a BMI <25·0 kg/m² and group 3 included participants with a BMI ≥25·0 kg/m². Human Performance Laboratory, Institute for Sport and Health, University College Dublin, Republic of Ireland. Forty-three female participants aged between 18 and 55 years. In all three groups, the %BF values estimated from the DW equation were closer to the criterion measure (i.e. ADP) than those estimated from the other equations. Of the three JPW equations, JPW₃ provided the most accurate estimation of %BF when compared with ADP in all three groups. In comparison to ADP, these findings suggest that the DW equation is the most accurate anthropometric method for the estimation of %BF in both normal-weight and overweight females.

  1. Toxicological Assessment of Inhaled Nanoparticles: Role of in Vivo, ex Vivo, in Vitro, and in Silico Studies

    PubMed Central

    Fröhlich, Eleonore; Salar-Behzadi, Sharareh

    2014-01-01

    The alveolar epithelium of the lung is by far the most permeable epithelial barrier of the human body. The risk for adverse effects by inhaled nanoparticles (NPs) depends on their hazard (negative action on cells and organism) and on exposure (concentration in the inhaled air and pattern of deposition in the lung). With the development of advanced in vitro models, not only in vivo, but also cellular studies can be used for toxicological testing. Advanced in vitro studies use combinations of cells cultured in the air-liquid interface. These cultures are useful for particle uptake and mechanistic studies. Whole-body, nose-only, and lung-only exposures of animals could help to determine retention of NPs in the body. Both approaches also have their limitations; cellular studies cannot mimic the entire organism and data obtained by inhalation exposure of rodents have limitations due to differences in the respiratory system from that of humans. Simulation programs for lung deposition in humans could help to determine the relevance of the biological findings. Combination of biological data generated in different biological models and in silico modeling appears suitable for a realistic estimation of potential risks by inhalation exposure to NPs. PMID:24646916

  2. Development and Validation of the Total HUman Model for Safety (THUMS) Toward Further Understanding of Occupant Injury Mechanisms in Precrash and During Crash.

    PubMed

    Iwamoto, Masami; Nakahira, Yuko; Kimpara, Hideyuki

    2015-01-01

    Active safety devices such as automatic emergency brake (AEB) and precrash seat belt have the potential to accomplish further reduction in the number of the fatalities due to automotive accidents. However, their effectiveness should be investigated by more accurate estimations of their interaction with human bodies. Computational human body models are suitable for investigation, especially considering muscular tone effects on occupant motions and injury outcomes. However, the conventional modeling approaches such as multibody models and detailed finite element (FE) models have advantages and disadvantages in computational costs and injury predictions considering muscular tone effects. The objective of this study is to develop and validate a human body FE model with whole body muscles, which can be used for the detailed investigation of interaction between human bodies and vehicular structures including some safety devices precrash and during a crash with relatively low computational costs. In this study, we developed a human body FE model called THUMS (Total HUman Model for Safety) with a body size of 50th percentile adult male (AM50) and a sitting posture. The model has anatomical structures of bones, ligaments, muscles, brain, and internal organs. The total number of elements is 281,260, which would realize relatively low computational costs. Deformable material models were assigned to all body parts. The muscle-tendon complexes were modeled by truss elements with Hill-type muscle material and seat belt elements with tension-only material. The THUMS was validated against 35 series of cadaver or volunteer test data on frontal, lateral, and rear impacts. Model validations for 15 series of cadaver test data associated with frontal impacts are presented in this article. The THUMS with a vehicle sled model was applied to investigate effects of muscle activations on occupant kinematics and injury outcomes in specific frontal impact situations with AEB. In the validations using 5 series of cadaver test data, force-time curves predicted by the THUMS were quantitatively evaluated using correlation and analysis (CORA), which showed good or acceptable agreement with cadaver test data in most cases. The investigation of muscular effects showed that muscle activation levels and timing had significant effects on occupant kinematics and injury outcomes. Although further studies on accident injury reconstruction are needed, the THUMS has the potential for predictions of occupant kinematics and injury outcomes considering muscular tone effects with relatively low computational costs.

  3. Allometric scaling for predicting human clearance of bisphenol A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collet, Séverine H., E-mail: s.collet@envt.fr; Picard-Hagen, Nicole, E-mail: n.hagen-picard@envt.fr; Lacroix, Marlène Z., E-mail: m.lacroix@envt.fr

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady statemore » volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.« less

  4. Control of a Robot Dancer for Enhancing Haptic Human-Robot Interaction in Waltz.

    PubMed

    Hongbo Wang; Kosuge, K

    2012-01-01

    Haptic interaction between a human leader and a robot follower in waltz is studied in this paper. An inverted pendulum model is used to approximate the human's body dynamics. With the feedbacks from the force sensor and laser range finders, the robot is able to estimate the human leader's state by using an extended Kalman filter (EKF). To reduce interaction force, two robot controllers, namely, admittance with virtual force controller, and inverted pendulum controller, are proposed and evaluated in experiments. The former controller failed the experiment; reasons for the failure are explained. At the same time, the use of the latter controller is validated by experiment results.

  5. Body composition and wages.

    PubMed

    Wada, Roy; Tekin, Erdal

    2010-07-01

    This paper examines the relationship between body composition and wages in the United States. We develop measures of body composition--body fat (BF) and fat-free mass (FFM)--using data on bioelectrical impedance analysis (BIA) that are available in the National Health and Nutrition Examination Survey III and estimate wage models for respondents in the National Longitudinal Survey of Youth 1979. Previous research uses body size or BMI as measures of obesity despite a growing concern that they do not distinguish between body fat and fat-free body mass or adequately control for non-homogeneity inside the human body. Therefore, measures presented in this paper represent a useful alternative to BMI-based proxies of obesity. Our results indicate that BF is associated with decreased wages for both males and females among whites and blacks. We also present evidence suggesting that FFM is associated with increased wages. We show that these results are not the artifacts of unobserved heterogeneity. Finally, our findings are robust to numerous specification checks and to a large number of alternative BIA prediction equations from which the body composition measures are derived. 2010 Elsevier B.V. All rights reserved.

  6. Do fungi need to be included within environmental radiation protection assessment models?

    PubMed

    Guillén, J; Baeza, A; Beresford, N A; Wood, M D

    2017-09-01

    Fungi are used as biomonitors of forest ecosystems, having comparatively high uptakes of anthropogenic and naturally occurring radionuclides. However, whilst they are known to accumulate radionuclides they are not typically considered in radiological assessment tools for environmental (non-human biota) assessment. In this paper the total dose rate to fungi is estimated using the ERICA Tool, assuming different fruiting body geometries, a single ellipsoid and more complex geometries considering the different components of the fruit body and their differing radionuclide contents based upon measurement data. Anthropogenic and naturally occurring radionuclide concentrations from the Mediterranean ecosystem (Spain) were used in this assessment. The total estimated weighted dose rate was in the range 0.31-3.4 μGy/h (5 th -95 th percentile), similar to natural exposure rates reported for other wild groups. The total estimated dose was dominated by internal exposure, especially from 226 Ra and 210 Po. Differences in dose rate between complex geometries and a simple ellipsoid model were negligible. Therefore, the simple ellipsoid model is recommended to assess dose rates to fungal fruiting bodies. Fungal mycelium was also modelled assuming a long filament. Using these geometries, assessments for fungal fruiting bodies and mycelium under different scenarios (post-accident, planned release and existing exposure) were conducted, each being based on available monitoring data. The estimated total dose rate in each case was below the ERICA screening benchmark dose, except for the example post-accident existing exposure scenario (the Chernobyl Exclusion Zone) for which a dose rate in excess of 35 μGy/h was estimated for the fruiting body. Estimated mycelium dose rate in this post-accident existing exposure scenario was close to the 400 μGy/h benchmark for plants, although fungi are generally considered to be less radiosensitive than plants. Further research on appropriate mycelium geometries and their radionuclide content is required. Based on the assessments presented in this paper, there is no need to recommend that fungi should be added to the existing assessment tools and frameworks; if required some tools allow a geometry representing fungi to be created and used within a dose assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Comparison of 3D dynamic virtual model to link segment model for estimation of net L4/L5 reaction moments during lifting.

    PubMed

    Abdoli-Eramaki, Mohammad; Stevenson, Joan M; Agnew, Michael J; Kamalzadeh, Amin

    2009-04-01

    The purpose of this study was to validate a 3D dynamic virtual model for lifting tasks against a validated link segment model (LSM). A face validation study was conducted by collecting x, y, z coordinate data and using them in both virtual and LSM models. An upper body virtual model was needed to calculate the 3D torques about human joints for use in simulated lifting styles and to estimate the effect of external mechanical devices on human body. Firstly, the model had to be validated to be sure it provided accurate estimates of 3D moments in comparison to a previously validated LSM. Three synchronised Fastrak units with nine sensors were used to record data from one male subject who completed dynamic box lifting under 27 different load conditions (box weights (3), lifting techniques (3) and rotations (3)). The external moments about three axes of L4/L5 were compared for both models. A pressure switch on the box was used to denote the start and end of the lift. An excellent agreement [image omitted] was found between the two models for dynamic lifting tasks, especially for larger moments in flexion and extension. This virtual model was considered valid for use in a complete simulation of the upper body skeletal system. This biomechanical virtual model of the musculoskeletal system can be used by researchers and practitioners to give a better tool to study the causes of LBP and the effect of intervention strategies, by permitting the researcher to see and control a virtual subject's motions.

  8. Low is large: spatial location and pitch interact in voice-based body size estimation.

    PubMed

    Pisanski, Katarzyna; Isenstein, Sari G E; Montano, Kelyn J; O'Connor, Jillian J M; Feinberg, David R

    2017-05-01

    The binding of incongruent cues poses a challenge for multimodal perception. Indeed, although taller objects emit sounds from higher elevations, low-pitched sounds are perceptually mapped both to large size and to low elevation. In the present study, we examined how these incongruent vertical spatial cues (up is more) and pitch cues (low is large) to size interact, and whether similar biases influence size perception along the horizontal axis. In Experiment 1, we measured listeners' voice-based judgments of human body size using pitch-manipulated voices projected from a high versus a low, and a right versus a left, spatial location. Listeners associated low spatial locations with largeness for lowered-pitch but not for raised-pitch voices, demonstrating that pitch overrode vertical-elevation cues. Listeners associated rightward spatial locations with largeness, regardless of voice pitch. In Experiment 2, listeners performed the task while sitting or standing, allowing us to examine self-referential cues to elevation in size estimation. Listeners associated vertically low and rightward spatial cues with largeness more for lowered- than for raised-pitch voices. These correspondences were robust to sex (of both the voice and the listener) and head elevation (standing or sitting); however, horizontal correspondences were amplified when participants stood. Moreover, when participants were standing, their judgments of how much larger men's voices sounded than women's increased when the voices were projected from the low speaker. Our results provide novel evidence for a multidimensional spatial mapping of pitch that is generalizable to human voices and that affects performance in an indirect, ecologically relevant spatial task (body size estimation). These findings suggest that crossmodal pitch correspondences evoke both low-level and higher-level cognitive processes.

  9. Equilibrium energy intake estimated by dietary energy intake and body weight changes in young Japanese females.

    PubMed

    Miyamoto, Kayoko; Nishimuta, Mamoru; Hamaoka, Takafumi; Kodama, Naoko; Yoshitake, Yutaka

    2012-01-01

    To determine the energy intake (EI) required to maintain body weight (equilibrium energy intake: EEI), we investigated the relationship between calculated energy intake and body weight changes in female subjects participating in 14 human balance studies (n=149) conducted at the National Institute of Health and Nutrition (Tokyo). In four and a half studies (n=43), sweat was collected from the arm to estimate loss of minerals through sweating during exercise on a bicycle ergometer; these subjects were classified in the exercise group (Ex G). In nine and a half experiments (n=106) subjects did not exercise, and were classified in the sedentary group (Sed G). The relationship between dietary energy intake (EI) and body weight (BW) changes (ΔBW) was analyzed and divided by four variables: body weight (BW), lean body mass (LBM), standard body weight (SBW), and body surface area (BSA). Equilibrium energy intake (EEI) and 95% confidence interval (CI) for EEI in Ex G were 34.3 and 32.8-35.9 kcal/kg BW/d, 32.0 and 30.8-33.1 kcal/kg SBW/d, 46.3 and 44.2-48.5 kcal/kg LBW/d, and 1,200 and 1,170-1,240 kcal/m(2) BSA/d, respectively. EEI and 95% CI for EEI in Sed G were 34.5 and 33.9-35.1 kcal/kg BW/d, 31.4 and 30.9-32.0 kcal/kg SBW/d, 44.9 and 44.1-45.8 kcal/kg LBM/d, and 1,200 and 1,180-1,210 kcal/m2 BSA/d, respectively. EEIs obtained in this study are 3 to 5% higher than estimated energy requirement (EER) for Japanese. In five out of six analyses, EER in a population (female, 18-29 y, physical activity level: 1.50) was under 95% CI of EEI obtained in this study.

  10. A model to estimate insulin sensitivity in dairy cows.

    PubMed

    Holtenius, Paul; Holtenius, Kjell

    2007-10-11

    Impairment of the insulin regulation of energy metabolism is considered to be an etiologic key component for metabolic disturbances. Methods for studies of insulin sensitivity thus are highly topical. There are clear indications that reduced insulin sensitivity contributes to the metabolic disturbances that occurs especially among obese lactating cows. Direct measurements of insulin sensitivity are laborious and not suitable for epidemiological studies. We have therefore adopted an indirect method originally developed for humans to estimate insulin sensitivity in dairy cows. The method, "Revised Quantitative Insulin Sensitivity Check Index" (RQUICKI) is based on plasma concentrations of glucose, insulin and free fatty acids (FFA) and it generates good and linear correlations with different estimates of insulin sensitivity in human populations. We hypothesized that the RQUICKI method could be used as an index of insulin function in lactating dairy cows. We calculated RQUICKI in 237 apparently healthy dairy cows from 20 commercial herds. All cows included were in their first 15 weeks of lactation. RQUICKI was not affected by the homeorhetic adaptations in energy metabolism that occurred during the first 15 weeks of lactation. In a cohort of 24 experimental cows fed in order to obtain different body condition at parturition RQUICKI was lower in early lactation in cows with a high body condition score suggesting disturbed insulin function in obese cows. The results indicate that RQUICKI might be used to identify lactating cows with disturbed insulin function.

  11. Channel Modeling of Miniaturized Battery-Powered Capacitive Human Body Communication Systems.

    PubMed

    Park, Jiwoong; Garudadri, Harinath; Mercier, Patrick P

    2017-02-01

    The purpose of this contribution is to estimate the path loss of capacitive human body communication (HBC) systems under practical conditions. Most prior work utilizes large grounded instruments to perform path loss measurements, resulting in overly optimistic path loss estimates for wearable HBC devices. In this paper, small battery-powered transmitter and receiver devices are implemented to measure path loss under realistic assumptions. A hybrid electrostatic finite element method simulation model is presented that validates measurements and enables rapid and accurate characterization of future capacitive HBC systems. Measurements from form-factor-accurate prototypes reveal path loss results between 31.7 and 42.2 dB from 20 to 150 MHz. Simulation results matched measurements within 2.5 dB. Comeasurements using large grounded benchtop vector network analyzer (VNA) and large battery-powered spectrum analyzer (SA) underestimate path loss by up to 33.6 and 8.2 dB, respectively. Measurements utilizing a VNA with baluns, or large battery-powered SAs with baluns still underestimate path loss by up to 24.3 and 6.7 dB, respectively. Measurements of path loss in capacitive HBC systems strongly depend on instrumentation configurations. It is thus imperative to simulate or measure path loss in capacitive HBC systems utilizing realistic geometries and grounding configurations. HBC has a great potential for many emerging wearable devices and applications; accurate path loss estimation will improve system-level design leading to viable products.

  12. Body size estimation of self and others in females varying in BMI.

    PubMed

    Thaler, Anne; Geuss, Michael N; Mölbert, Simone C; Giel, Katrin E; Streuber, Stephan; Romero, Javier; Black, Michael J; Mohler, Betty J

    2018-01-01

    Previous literature suggests that a disturbed ability to accurately identify own body size may contribute to overweight. Here, we investigated the influence of personal body size, indexed by body mass index (BMI), on body size estimation in a non-clinical population of females varying in BMI. We attempted to disentangle general biases in body size estimates and attitudinal influences by manipulating whether participants believed the body stimuli (personalized avatars with realistic weight variations) represented their own body or that of another person. Our results show that the accuracy of own body size estimation is predicted by personal BMI, such that participants with lower BMI underestimated their body size and participants with higher BMI overestimated their body size. Further, participants with higher BMI were less likely to notice the same percentage of weight gain than participants with lower BMI. Importantly, these results were only apparent when participants were judging a virtual body that was their own identity (Experiment 1), but not when they estimated the size of a body with another identity and the same underlying body shape (Experiment 2a). The different influences of BMI on accuracy of body size estimation and sensitivity to weight change for self and other identity suggests that effects of BMI on visual body size estimation are self-specific and not generalizable to other bodies.

  13. Body size estimation of self and others in females varying in BMI

    PubMed Central

    Geuss, Michael N.; Mölbert, Simone C.; Giel, Katrin E.; Streuber, Stephan; Romero, Javier; Black, Michael J.; Mohler, Betty J.

    2018-01-01

    Previous literature suggests that a disturbed ability to accurately identify own body size may contribute to overweight. Here, we investigated the influence of personal body size, indexed by body mass index (BMI), on body size estimation in a non-clinical population of females varying in BMI. We attempted to disentangle general biases in body size estimates and attitudinal influences by manipulating whether participants believed the body stimuli (personalized avatars with realistic weight variations) represented their own body or that of another person. Our results show that the accuracy of own body size estimation is predicted by personal BMI, such that participants with lower BMI underestimated their body size and participants with higher BMI overestimated their body size. Further, participants with higher BMI were less likely to notice the same percentage of weight gain than participants with lower BMI. Importantly, these results were only apparent when participants were judging a virtual body that was their own identity (Experiment 1), but not when they estimated the size of a body with another identity and the same underlying body shape (Experiment 2a). The different influences of BMI on accuracy of body size estimation and sensitivity to weight change for self and other identity suggests that effects of BMI on visual body size estimation are self-specific and not generalizable to other bodies. PMID:29425218

  14. Estimation of Quasi-Stiffness of the Human Hip in the Stance Phase of Walking

    PubMed Central

    Shamaei, Kamran; Sawicki, Gregory S.; Dollar, Aaron M.

    2013-01-01

    This work presents a framework for selection of subject-specific quasi-stiffness of hip orthoses and exoskeletons, and other devices that are intended to emulate the biological performance of this joint during walking. The hip joint exhibits linear moment-angular excursion behavior in both the extension and flexion stages of the resilient loading-unloading phase that consists of terminal stance and initial swing phases. Here, we establish statistical models that can closely estimate the slope of linear fits to the moment-angle graph of the hip in this phase, termed as the quasi-stiffness of the hip. Employing an inverse dynamics analysis, we identify a series of parameters that can capture the nearly linear hip quasi-stiffnesses in the resilient loading phase. We then employ regression analysis on experimental moment-angle data of 216 gait trials across 26 human adults walking over a wide range of gait speeds (0.75–2.63 m/s) to obtain a set of general-form statistical models that estimate the hip quasi-stiffnesses using body weight and height, gait speed, and hip excursion. We show that the general-form models can closely estimate the hip quasi-stiffness in the extension (R2 = 92%) and flexion portions (R2 = 89%) of the resilient loading phase of the gait. We further simplify the general-form models and present a set of stature-based models that can estimate the hip quasi-stiffness for the preferred gait speed using only body weight and height with an average error of 27% for the extension stage and 37% for the flexion stage. PMID:24349136

  15. Electrical Impedance Tomography: a new study method for neonatal Respiratory Distress Syndrome?

    PubMed Central

    Chatziioannidis, I; Samaras, T; Nikolaidis, N

    2011-01-01

    Treatment of cardiorespiratory system diseases is a procedure that usually demands data collection on terms of the anatomy and the operation of the organs that are under study. Electrical Impedance Tomography (EIT) is an alternative approach, in comparison to existing techniques. With EIT electrodes are placed in the perimeter of the human body and images of the estimated organ are reconstructed, using the measurement of its impendence (or resistance) distribution and determining its alteration through time, while at the same time the patient is not exposed to ionizing radiation. Its clinical use presupposes the correct placement of the electrodes over the perimeter of the human body, the rapid data collection and electrical safety. It is a low cost technique and it is implemented near the patient. It is able to determine the distribution of ventilation, blood supply, diffused or localized lung defects, but it can also estimate therapeutic interventions or alteration to assisted ventilation of the neonate. EIT was developed at the beginning of the 1980s, but it has only recently begun to be implemented on neonates, and especially in the study of their respiratory system function. The low rate of image analysis is considered to be a drawback, but it is offset by the potential offered for the estimation of lungs' function (both under normal and pathological conditions), since ventilation and resistance are two quite similar concepts. In this review the most important studies about EIT are mentioned as a method of estimating respiratory distress syndrome in neonates. In terms of the above mentioned development, it is supposed that this technique will offer a great amount of help to the doctor in his / her estimations of the cardiorespiratory system and to his / her selection of the best intervening strategies. PMID:22435017

  16. New directions in the toxicokinetics of human lead exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mushak, P.

    An important determinant of body lead (Pb) burden and Pb toxicity in exposed humans is Pb metabolism, or more correctly, Pb toxicokinetics. It affects the former through the quantitative processes of uptake, distribution and retention/excretion and the latter via delivery of toxic doses to cellular/molecular sites of action. Pb toxicokinetics has useful application in understanding Pb's behavior in populations. Several of these applications have been studied and results are presented for the toxicokinetic basis of dose-neurotoxic effect relationships in selected longitudinal studies and the use of toxicokinetic modeling for estimation of body lead burden in early populations. Three well-known, ongoingmore » longitudinal studies of developmental neurotoxicity--in Boston, Cincinnati, and Port Pirie, Australia--involve cohorts who differ markedly as to their pre- and postnatal lead exposure profiles. Toxicokinetic examination of these exposure differences helps to explain the temporal variability seen in blood Pb-toxic effect relationships and supports a causal role for lead. Toxicokinetic models of Pb uptake and in-vivo behavior are increasingly being considered for estimating Pb-B levels in lieu of direct measurement. A linear biokinetic model, using reliable input data for natural/prehistoric levels of Pb in sources, was applied to estimation of prehistoric/preindustrial children's blood lead. A range of 0.06 to 0.12 microgram/dl was estimated for two lead intakes. These estimates are still two orders of magnitude (85 to 165-fold) lower than the newly issued CDC toxicity guideline for children of 10 micrograms/dl. Lastly, the toxicokinetics of lead in bone, particularly its resorption with metabolic stimuli, is of concern, particularly for baby boom women who are either of childbearing age or approaching menopause and who had greatly elevated environmental lead exposures in the 1940s to 1970s. 115 refs.« less

  17. An arm phantom for in vivo determination of Americium-241 in bone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kephart, G.S.; Palmer, H.E.

    1988-04-01

    The focus of this research has been to construct a realistic arm phantom as a calibration tool in estimation of /sup 241/Am in the bone. The United States Transuranium Registry (USTR), through its program of whole body donations, continues to provide data on transuranic incorporation in man that would not otherwise be readily available (Norwood 1972; Breitenstein 1981; Swint, et al. 1985). This project uses well-characterized human bones loaned by the USTR for the construction of realistic phantoms for improvement of whole-body counter calibrations. 27 refs., 2 figs., 4 tabs.

  18. Human health risk analysis from disinfection by-products (DBPs) in drinking and bathing water of some Indian cities

    PubMed Central

    2014-01-01

    Background Human health risk assessment from exposure to disinfection by-products (DBPs) during drinking and bathing water vary from country to country as per life expectancy, body mass index, water consumption pattern and individual concentration of DBPs component, etc. Methods Present study considered average direct water intake per person for adult males and females as 4 & 3 L/day, respectively as per Indian literature for risk evaluation from another component of pollutant. While other important factor like average life expectancy, body weight & body surface area for male and female were considered 64 & 67 years, 51.9 & 45.4 Kg and 1.54 & 1.38 m2 respectively as per Indian Council of Medical Research and WHO report. The corresponding lifetime cancer risk of the formed THMs to human beings was estimated by the USEPA and IRIS method as per Indian population. Results The total cancer risk reached 8.99 E-04 and 8.92 E-04 for males and females, respectively, the highest risk from THMs seems to be from the inhalation route followed by ingestion and dermal contacts. Conclusions The multipath way evaluations of lifetime cancer risks for THMs exposure through ingestion, dermal absorption, and inhalation exposure were examined at the highest degree of danger. Results reveals that water containing THMs of the selected water treatment plant of the eastern part of India was unsafe in terms of risk evaluation through inhalation and ingestion, while dermal route of risk was found very close to permissible limit of USEPA. Sensitivity analysis shows that every input parameter is sole responsible for total risk potential, whereas exposure duration playing important role for estimation of total risk. PMID:24872885

  19. [Progress in environmental exposure of organophosphate flame retardants].

    PubMed

    Ding, J J; Yang, F X

    2017-06-06

    Organophosphate flame retardants (OPFRs), which have both great properties of flame retardation and plasticization, are currently widely used as additive flame retardants. Due to the restriction and phase-out of brominated flame retardants (BFRs), the market demand for OPFRs as excellent alternatives of BFRs has been rapid increasing. OPFRs can be slowly released into the environment during production and application. Some OPFRs might be persistent in the environment. As a result, OPFRs have been detected in various matrices in the environment and are expected to accumulate in human body through various pathways. OPFRs may cause adverse effects to human health as some of them have been identified as neurotoxicants, reproductive toxicants and potential carcinogens. The article summarized the occurrence and patterns of OPFRs in various environmental matrices such as air, dust, water, food and so on, and in human specimens, estimates the exposure status through different pathways and body burdens of OPFRs. The expected hotspots of OPFRs were also discussed in the future.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, L.R.

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- andmore » inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.« less

  1. Thermometry, calorimetry, and mean body temperature during heat stress.

    PubMed

    Kenny, Glen P; Jay, Ollie

    2013-10-01

    Heat balance in humans is maintained at near constant levels through the adjustment of physiological mechanisms that attain a balance between the heat produced within the body and the heat lost to the environment. Heat balance is easily disturbed during changes in metabolic heat production due to physical activity and/or exposure to a warmer environment. Under such conditions, elevations of skin blood flow and sweating occur via a hypothalamic negative feedback loop to maintain an enhanced rate of dry and evaporative heat loss. Body heat storage and changes in core temperature are a direct result of a thermal imbalance between the rate of heat production and the rate of total heat dissipation to the surrounding environment. The derivation of the change in body heat content is of fundamental importance to the physiologist assessing the exposure of the human body to environmental conditions that result in thermal imbalance. It is generally accepted that the concurrent measurement of the total heat generated by the body and the total heat dissipated to the ambient environment is the most accurate means whereby the change in body heat content can be attained. However, in the absence of calorimetric methods, thermometry is often used to estimate the change in body heat content. This review examines heat exchange during challenges to heat balance associated with progressive elevations in environmental heat load and metabolic rate during exercise. Further, we evaluate the physiological responses associated with heat stress and discuss the thermal and nonthermal influences on the body's ability to dissipate heat from a heat balance perspective.

  2. Molecular Tools for Investigating the Gut Microbiota

    NASA Astrophysics Data System (ADS)

    Lay, Christophe

    The “microbial world within us” (Zoetendal et al., 2006) is populated by a complex society of indigenous microorganisms that feature different “ethnic” populations. Those microbial cells thriving within us are estimated to outnumber human body cells by a factor of ten to one. Insights into the relation between the intestinal microbial community and its host have been gained through gnotobiology. Indeed, the influence of the gut microbiota upon human development, physiology, immunity, and nutrition has been inferred by comparing gnotoxenic and axenic murine models (Hooper et al., 1998, 2002, 2003; Hooper and Gordon, 2001).

  3. Improving IMES Localization Accuracy by Integrating Dead Reckoning Information

    PubMed Central

    Fujii, Kenjiro; Arie, Hiroaki; Wang, Wei; Kaneko, Yuto; Sakamoto, Yoshihiro; Schmitz, Alexander; Sugano, Shigeki

    2016-01-01

    Indoor positioning remains an open problem, because it is difficult to achieve satisfactory accuracy within an indoor environment using current radio-based localization technology. In this study, we investigate the use of Indoor Messaging System (IMES) radio for high-accuracy indoor positioning. A hybrid positioning method combining IMES radio strength information and pedestrian dead reckoning information is proposed in order to improve IMES localization accuracy. For understanding the carrier noise ratio versus distance relation for IMES radio, the signal propagation of IMES radio is modeled and identified. Then, trilateration and extended Kalman filtering methods using the radio propagation model are developed for position estimation. These methods are evaluated through robot localization and pedestrian localization experiments. The experimental results show that the proposed hybrid positioning method achieved average estimation errors of 217 and 1846 mm in robot localization and pedestrian localization, respectively. In addition, in order to examine the reason for the positioning accuracy of pedestrian localization being much lower than that of robot localization, the influence of the human body on the radio propagation is experimentally evaluated. The result suggests that the influence of the human body can be modeled. PMID:26828492

  4. Motion estimation using point cluster method and Kalman filter.

    PubMed

    Senesh, M; Wolf, A

    2009-05-01

    The most frequently used method in a three dimensional human gait analysis involves placing markers on the skin of the analyzed segment. This introduces a significant artifact, which strongly influences the bone position and orientation and joint kinematic estimates. In this study, we tested and evaluated the effect of adding a Kalman filter procedure to the previously reported point cluster technique (PCT) in the estimation of a rigid body motion. We demonstrated the procedures by motion analysis of a compound planar pendulum from indirect opto-electronic measurements of markers attached to an elastic appendage that is restrained to slide along the rigid body long axis. The elastic frequency is close to the pendulum frequency, as in the biomechanical problem, where the soft tissue frequency content is similar to the actual movement of the bones. Comparison of the real pendulum angle to that obtained by several estimation procedures--PCT, Kalman filter followed by PCT, and low pass filter followed by PCT--enables evaluation of the accuracy of the procedures. When comparing the maximal amplitude, no effect was noted by adding the Kalman filter; however, a closer look at the signal revealed that the estimated angle based only on the PCT method was very noisy with fluctuation, while the estimated angle based on the Kalman filter followed by the PCT was a smooth signal. It was also noted that the instantaneous frequencies obtained from the estimated angle based on the PCT method is more dispersed than those obtained from the estimated angle based on Kalman filter followed by the PCT method. Addition of a Kalman filter to the PCT method in the estimation procedure of rigid body motion results in a smoother signal that better represents the real motion, with less signal distortion than when using a digital low pass filter. Furthermore, it can be concluded that adding a Kalman filter to the PCT procedure substantially reduces the dispersion of the maximal and minimal instantaneous frequencies.

  5. ArcNLET: A GIS-based software to simulate groundwater nitrate load from septic systems to surface water bodies

    NASA Astrophysics Data System (ADS)

    Rios, J. Fernando; Ye, Ming; Wang, Liying; Lee, Paul Z.; Davis, Hal; Hicks, Rick

    2013-03-01

    Onsite wastewater treatment systems (OWTS), or septic systems, can be a significant source of nitrates in groundwater and surface water. The adverse effects that nitrates have on human and environmental health have given rise to the need to estimate the actual or potential level of nitrate contamination. With the goal of reducing data collection and preparation costs, and decreasing the time required to produce an estimate compared to complex nitrate modeling tools, we developed the ArcGIS-based Nitrate Load Estimation Toolkit (ArcNLET) software. Leveraging the power of geographic information systems (GIS), ArcNLET is an easy-to-use software capable of simulating nitrate transport in groundwater and estimating long-term nitrate loads from groundwater to surface water bodies. Data requirements are reduced by using simplified models of groundwater flow and nitrate transport which consider nitrate attenuation mechanisms (subsurface dispersion and denitrification) as well as spatial variability in the hydraulic parameters and septic tank distribution. ArcNLET provides a spatial distribution of nitrate plumes from multiple septic systems and a load estimate to water bodies. ArcNLET's conceptual model is divided into three sub-models: a groundwater flow model, a nitrate transport and fate model, and a load estimation model which are implemented as an extension to ArcGIS. The groundwater flow model uses a map of topography in order to generate a steady-state approximation of the water table. In a validation study, this approximation was found to correlate well with a water table produced by a calibrated numerical model although it was found that the degree to which the water table resembles the topography can vary greatly across the modeling domain. The transport model uses a semi-analytical solution to estimate the distribution of nitrate within groundwater, which is then used to estimate a nitrate load using a mass balance argument. The estimates given by ArcNLET are suitable for a screening-level analysis.

  6. Illustrating the body: Cross-sectional and prospective investigations of the impact of life drawing sessions on body image.

    PubMed

    Swami, Viren

    2016-01-30

    Life drawing sessions, where individuals produce drawings of the human figure from observations of a live model, may contain embodying elements that promote healthier body image. Two pilot studies were conducted to test this hypothesis. In Study 1, 138 individuals recruited from life drawing sessions in London, UK, estimated how many sessions they had attended in their lifetime and completed measures of negative and positive body image. In women, greater attendance was significantly associated with higher body appreciation and lower drive for thinness and social physique anxiety. In men, greater attendance was significantly associated with higher body appreciation, but not drive for muscularity or social physique anxiety. In Study 2, 37 women took part in a life drawing session for the first time. Compared to pre-session scores, participants had significantly more positive state body image and appearance satisfaction after the session. The findings of these studies suggest that life drawing may promote healthier body image, particularly among women, but further research is needed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Toxicity of cadmium and its health risks from leafy vegetable consumption.

    PubMed

    Huang, Yingying; He, Chuntao; Shen, Chuang; Guo, Jingjie; Mubeen, Samavia; Yuan, Jiangang; Yang, Zhongyi

    2017-04-19

    Cadmium (Cd) is a highly toxic heavy metal and has spread widely in the environment in recent decades. This review summarizes current knowledge about Cd contamination of leafy vegetables, its toxicity, exposure, health risks, and approaches to reducing its toxicity in humans. Leafy vegetable consumption has been identified as a dominant exposure pathway of Cd in the human body. An overview of Cd pollution in leafy vegetables as well as the main sources of Cd is given. Notable estimated daily intakes and health risks of Cd exposure through vegetable consumption for humans are revealed in occupational exposure areas and even in some reference areas. Vegetable consumption is one of the most significant sources of exposure to Cd, particularly in occupational exposure regions. Therefore, numerous approaches have been developed to minimize the accumulation of Cd in leafy vegetables, among which the breeding of Cd pollution-safe cultivars is one of the most effective tools. Furthermore, dietary supplements from leafy vegetables perform positive roles in alleviating Cd toxicity in humans with regard to the effects of essential mineral elements, vitamins and phytochemicals taken into the human body via leafy vegetable consumption.

  8. Extracting motor synergies from random movements for low-dimensional task-space control of musculoskeletal robots.

    PubMed

    Fu, Kin Chung Denny; Dalla Libera, Fabio; Ishiguro, Hiroshi

    2015-10-08

    In the field of human motor control, the motor synergy hypothesis explains how humans simplify body control dimensionality by coordinating groups of muscles, called motor synergies, instead of controlling muscles independently. In most applications of motor synergies to low-dimensional control in robotics, motor synergies are extracted from given optimal control signals. In this paper, we address the problems of how to extract motor synergies without optimal data given, and how to apply motor synergies to achieve low-dimensional task-space tracking control of a human-like robotic arm actuated by redundant muscles, without prior knowledge of the robot. We propose to extract motor synergies from a subset of randomly generated reaching-like movement data. The essence is to first approximate the corresponding optimal control signals, using estimations of the robot's forward dynamics, and to extract the motor synergies subsequently. In order to avoid modeling difficulties, a learning-based control approach is adopted such that control is accomplished via estimations of the robot's inverse dynamics. We present a kernel-based regression formulation to estimate the forward and the inverse dynamics, and a sliding controller in order to cope with estimation error. Numerical evaluations show that the proposed method enables extraction of motor synergies for low-dimensional task-space control.

  9. In vivo assessment of magnesium status in human body using accelerator-based neutron activation measurement of hands: a pilot study.

    PubMed

    Aslam; Pejović-Milić, A; McNeill, F E; Byun, S H; Prestwich, W V; Chettle, D R

    2008-02-01

    Magnesium (Mg) is an element essential for many enzymatic reactions in the human body. Various human and animal studies suggest that changes in Mg status are linked to diseases such as cardiac arrhythmia, coronary heart disease, hypertension, premenstrual syndrome, and diabetes mellitus. Thus, knowledge of Mg levels in the human body is needed. A direct measurement of human blood serum, which contains only 0.3% of the total body Mg, is generally used to infer information about the status of Mg in the body. However, in many clinical situations, Mg stored in large levels, for example in bones, muscles, and soft tissues, needs to be monitored either to evaluate the efficacy of a treatment or to study the progression of diseases associated with the deficiency of total body Mg. This work presents a feasibility study of a noninvasive, in vivo neutron activation analysis (IVNAA) technique using the 26Mg (n, gamma) 27Mg reaction to measure Mg levels in human hands. The technique employs the McMaster University high beam current Tandetron accelerator hand irradiation facility and an array of eight NaI (T1) detectors arranged in a 4 pi geometry for delayed counting of the 0.844 and 1.014 MeV gamma rays emitted when 27Mg decays in the irradiated hand. Mg determination in humans using IVNAA of hands has been demonstrated to be feasible, with effective doses as low as one-quarter of those delivered in chest x rays. The overall experimental uncertainty in the measurements is estimated to be approximately 5% (1 sigma). The results are found to be in the range of the in vitro measurements reported for other cortical bones collected from different sites of the human skeleton, which confirms that this technique mainly provides a measure of the amount of Mg in hand bones. The average concentration of Mg determined in human hands is 10.96 +/- 1.25 (+/- 1 SD) mg Mg/g Ca. The coefficient of variation (11%) observed in this study is comparable with or lower than several studies using in vitro measurements reported in the literature and therefore allows for a quantitative intersubject comparison, even if to a limited extent. The features of the developed technique such as its simplicity, rapidity, accuracy, robustness, noninvasive nature, and very effective use of radiation doses, present the technique as a viable diagnostic tool available for trial in a clinical environment.

  10. Refined gravity determination at small bodies through landing probes

    NASA Astrophysics Data System (ADS)

    Bellerose, J.

    2012-02-01

    Very small objects of the near-Earth population have not been visited to date, and may be among the next targets for human exploration. As density is a strong indication of the body origin and intrinsic properties, determining the mass is one of the most important goals. The past missions to Eros and Itokawa resulted in mass and density estimates to less than five percent error, allowing precise mission planning while giving new insights on the body structure. Current mass determination techniques have limitations in the low gravity regime, and spacecraft tracking at very small asteroids is challenging. We investigate the constraints on measuring the mass at very small near-Earth objects, and their consequences on proximity operation planning. An alternative option to spacecraft radio tracking is to use surface probes. The near-surface and landing dynamics can be observed and tracked by the host spacecraft, providing higher resolution measurements of the NEA gravity pull. We show analytical methods to estimate the performance of given proximity operations, and simulations of spacecraft and probe dynamics at NEAs less than 100 m in diameter.

  11. Variation in the human ribs geometrical properties and mechanical response based on X-ray computed tomography images resolution.

    PubMed

    Perz, Rafał; Toczyski, Jacek; Subit, Damien

    2015-01-01

    Computational models of the human body are commonly used for injury prediction in automobile safety research. To create these models, the geometry of the human body is typically obtained from segmentation of medical images such as computed tomography (CT) images that have a resolution between 0.2 and 1mm/pixel. While the accuracy of the geometrical and structural information obtained from these images depend greatly on their resolution, the effect of image resolution on the estimation of the ribs geometrical properties has yet to be established. To do so, each of the thirty-four sections of ribs obtained from a Post Mortem Human Surrogate (PMHS) was imaged using three different CT modalities: standard clinical CT (clinCT), high resolution clinical CT (HRclinCT), and microCT. The images were processed to estimate the rib cross-section geometry and mechanical properties, and the results were compared to those obtained from the microCT images by computing the 'deviation factor', a metric that quantifies the relative difference between results obtained from clinCT and HRclinCT to those obtained from microCT. Overall, clinCT images gave a deviation greater than 100%, and were therefore deemed inadequate for the purpose of this study. HRclinCT overestimated the rib cross-sectional area by 7.6%, the moments of inertia by about 50%, and the cortical shell area by 40.2%, while underestimating the trabecular area by 14.7%. Next, a parametric analysis was performed to quantify how the variations in the estimate of the geometrical properties affected the rib predicted mechanical response under antero-posterior loading. A variation of up to 45% for the predicted peak force and up to 50% for the predicted stiffness was observed. These results provide a quantitative estimate of the sensitivity of the response of the FE model to the resolution of the images used to generate it. They also suggest that a correction factor could be derived from the comparison between microCT and HRclinCT images to improve the response of the model developed based on HRclinCT images. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. The generation of simple compliance boundaries for mobile communication base station antennas using formulae for SAR estimation.

    PubMed

    Thors, B; Hansson, B; Törnevik, C

    2009-07-07

    In this paper, a procedure is proposed for generating simple and practical compliance boundaries for mobile communication base station antennas. The procedure is based on a set of formulae for estimating the specific absorption rate (SAR) in certain directions around a class of common base station antennas. The formulae, given for both whole-body and localized SAR, require as input the frequency, the transmitted power and knowledge of antenna-related parameters such as dimensions, directivity and half-power beamwidths. With knowledge of the SAR in three key directions it is demonstrated how simple and practical compliance boundaries can be generated outside of which the exposure levels do not exceed certain limit values. The conservativeness of the proposed procedure is discussed based on results from numerical radio frequency (RF) exposure simulations with human body phantoms from the recently developed Virtual Family.

  13. Center of gravity estimation using a reaction board instrumented with fiber Bragg gratings

    NASA Astrophysics Data System (ADS)

    Oliveira, Rui; Roriz, Paulo; Marques, Manuel B.; Frazão, Orlando

    2018-03-01

    The purpose of the present work is to construct a reaction board based on fiber Bragg gratings (FBGs) that could be used for estimation of the 2D coordinates of the projection of center of gravity (CG) of an object. The apparatus is consisted of a rigid equilateral triangular board mounted on three supports at the vertices, two of which have cantilevers instrumented with FBGs. When an object of known weight is placed on the board, the bending strain of the cantilevers is measured by a proportional wavelength shift of the FBGs. Applying the equilibrium conditions of a rigid body and proper calibration procedures, the wavelength shift is used to estimate the vertical reaction forces and moments of force at the supports and the coordinates of the object's CG projection on the board. This method can be used on a regular basis to estimate the CG of the human body or objects with complex geometry and density distribution. An example is provided for the estimation of the CG projection coordinates of two orthopaedic femur bone models, one intact, and the other with a hip stem implant encased. The clinical implications of changing the normal CG location by means of a prosthesis have been discussed.

  14. Transport calculations and accelerator experiments needed for radiation risk assessment in space.

    PubMed

    Sihver, Lembit

    2008-01-01

    The major uncertainties on space radiation risk estimates in humans are associated to the poor knowledge of the biological effects of low and high LET radiation, with a smaller contribution coming from the characterization of space radiation field and its primary interactions with the shielding and the human body. However, to decrease the uncertainties on the biological effects and increase the accuracy of the risk coefficients for charged particles radiation, the initial charged-particle spectra from the Galactic Cosmic Rays (GCRs) and the Solar Particle Events (SPEs), and the radiation transport through the shielding material of the space vehicle and the human body, must be better estimated Since it is practically impossible to measure all primary and secondary particles from all possible position-projectile-target-energy combinations needed for a correct risk assessment in space, accurate particle and heavy ion transport codes must be used. These codes are also needed when estimating the risk for radiation induced failures in advanced microelectronics, such as single-event effects, etc., and the efficiency of different shielding materials. It is therefore important that the models and transport codes will be carefully benchmarked and validated to make sure they fulfill preset accuracy criteria, e.g. to be able to predict particle fluence, dose and energy distributions within a certain accuracy. When validating the accuracy of the transport codes, both space and ground based accelerator experiments are needed The efficiency of passive shielding and protection of electronic devices should also be tested in accelerator experiments and compared to simulations using different transport codes. In this paper different multipurpose particle and heavy ion transport codes will be presented, different concepts of shielding and protection discussed, as well as future accelerator experiments needed for testing and validating codes and shielding materials.

  15. An allometric pharmacokinetic/pharmacodynamics model for BI 893923, a novel IGF-1 receptor inhibitor.

    PubMed

    Titze, Melanie I; Schaaf, Otmar; Hofmann, Marco H; Sanderson, Michael P; Zahn, Stephan K; Quant, Jens; Lehr, Thorsten

    2017-03-01

    BI 893923 is a novel IGF1R/INSR inhibitor with promising anti-tumor efficacy. Dose-limiting hyperglycemia has been observed for other IGF1R/INSR inhibitors in clinical trials. To counterbalance anti-tumor efficacy with the risk of hyperglycemia and to determine the therapeutic window, we aimed to develop a translational pharmacokinetic/pharmacodynamics model for BI 893923. This aimed to translate pharmacokinetics and pharmacodynamics from animals to humans by an allometrically scaled semi-mechanistic model. Model development was based on a previously published PK/PD model for BI 893923 in mice (Titze et al., Cancer Chemother Pharmacol 77:1303-1314, 13). PK and blood glucose parameters were scaled by allometric principles using body weight as a scaling factor along with an estimation of the parameter exponents. Biomarker and tumor growth parameters were extrapolated from mouse to human using the body weight ratio as scaling factor. The allometric PK/PD model successfully described BI 893923 pharmacokinetics and blood glucose across mouse, rat, dog, minipig, and monkey. BI 893923 human exposure as well as blood glucose and tumor growth were predicted and compared for different dosing scenarios. A comprehensive risk-benefit analysis was conducted by determining the net clinical benefit for each schedule. An oral dose of 2750 mg BI 893923 divided in three evenly distributed doses was identified as the optimal human dosing regimen, predicting a tumor growth inhibition of 90.4% without associated hyperglycemia. Our model supported human therapeutic dose estimation by rationalizing the optimal efficacious dosing regimen with minimal undesired effects. This modeling approach may be useful for PK/PD scaling of other IGF1R/INSR inhibitors.

  16. New Radiation Dosimetry Estimates for [18F]FLT based on Voxelized Phantoms.

    PubMed

    Mendes, B M; Ferreira, A V; Nascimento, L T C; Ferreira, S M Z M D; Silveira, M B; Silva, J B

    2018-04-25

    3'-Deoxy-3-[ 18 F]fluorothymidine, or [ 18 F]FLT, is a positron emission tomography (PET) tracer used in clinical studies for noninvasive assessment of proliferation activity in several types of cancer. Although the use of this PET tracer is expanding, to date, few studies concerning its dosimetry have been published. In this work, new [ 18 F]FLT dosimetry estimates are determined for human and mice using Monte Carlo simulations. Modern voxelized male and female phantoms and [ 18 F]FLT biokinetic data, both published by the ICRP, were used for simulations of human cases. For most human organs/tissues the absorbed doses were higher than those reported in ICRP Publication 128. An effective dose of 1.70E-02 mSv/MBq to the whole body was determined, which is 13.5% higher than the ICRP reference value. These new human dosimetry estimates obtained using more realistic human phantoms represent an advance in the knowledge of [ 18 F]FLT dosimetry. In addition, mice biokinetic data were obtained experimentally. These data and a previously developed voxelized mouse phantom were used for simulations of animal cases. Concerning animal dosimetry, absorbed doses for organs/tissues ranged from 4.47 ± 0.75 to 155.74 ± 59.36 mGy/MBq. The obtained set of organ/tissue radiation doses for healthy Swiss mice is a useful tool for application in animal experiment design.

  17. Development of a Sampler for Total Aerosol Deposition in the Human Respiratory Tract

    PubMed Central

    Koehler, Kirsten A.; Clark, Phillip; Volckens, John

    2009-01-01

    Studies that seek to associate reduced human health with exposure to occupational and environmental aerosols are often hampered by limitations in the exposure assessment process. One limitation involves the measured exposure metric itself. Current methods for personal exposure assessment are designed to estimate the aspiration of aerosol into the human body. Since a large proportion of inhaled aerosol is subsequently exhaled, a portion of the aspirated aerosol will not contribute to the dose. This leads to variable exposure misclassification (for heterogenous exposures) and increased uncertainty in health effect associations. Alternatively, a metric for respiratory deposition would provide a more physiologically relevant estimate of risk. To address this challenge, we have developed a method to estimate the deposition of aerosol in the human respiratory tract using a sampler engineered from polyurethane foam. Using a semi-empirical model based on inertial, gravitational, and diffusional particle deposition, a foam was engineered to mimic aerosol total deposition in the human respiratory tract. The sampler is comprised of commercially available foam with fiber diameter = 49.5 μm (equivalent to industry standard 100 PPI foam) of 8 cm thickness operating at a face velocity of 1.3 m s−1. Additionally, the foam sampler yields a relatively low-pressure drop, independent of aerosol loading, providing uniform particle collection efficiency over time. PMID:19638392

  18. Age-Related Differences in Susceptibility to Carcinogenesis. II. Approaches for Application and Uncertainty Analyses for Individual Genetically Acting Carcinogens

    PubMed Central

    Hattis, Dale; Goble, Robert; Chu, Margaret

    2005-01-01

    In an earlier report we developed a quantitative likelihood-based analysis of the differences in sensitivity of rodents to mutagenic carcinogens across three life stages (fetal, birth to weaning, and weaning to 60 days) relative to exposures in adult life. Here we draw implications for assessing human risks for full lifetime exposures, taking into account three types of uncertainties in making projections from the rodent data: uncertainty in the central estimates of the life-stage–specific sensitivity factors estimated earlier, uncertainty from chemical-to-chemical differences in life-stage–specific sensitivities for carcinogenesis, and uncertainty in the mapping of rodent life stages to human ages/exposure periods. Among the uncertainties analyzed, the mapping of rodent life stages to human ages/exposure periods is most important quantitatively (a range of several-fold in estimates of the duration of the human equivalent of the highest sensitivity “birth to weaning” period in rodents). The combined effects of these uncertainties are estimated with Monte Carlo analyses. Overall, the estimated population arithmetic mean risk from lifetime exposures at a constant milligrams per kilogram body weight level to a generic mutagenic carcinogen is about 2.8-fold larger than expected from adult-only exposure with 5–95% confidence limits of 1.5-to 6-fold. The mean estimates for the 0- to 2-year and 2- to 15-year periods are about 35–55% larger than the 10- and 3-fold sensitivity factor adjustments recently proposed by the U.S. Environmental Protection Agency. The present results are based on data for only nine chemicals, including five mutagens. Risk inferences will be altered as data become available for other chemicals. PMID:15811844

  19. Bivariate genome-wide association meta-analysis of pediatric musculoskeletal traits reveals pleiotropic effects at the SREBF1/TOM1L2 locus.

    PubMed

    Medina-Gomez, Carolina; Kemp, John P; Dimou, Niki L; Kreiner, Eskil; Chesi, Alessandra; Zemel, Babette S; Bønnelykke, Klaus; Boer, Cindy G; Ahluwalia, Tarunveer S; Bisgaard, Hans; Evangelou, Evangelos; Heppe, Denise H M; Bonewald, Lynda F; Gorski, Jeffrey P; Ghanbari, Mohsen; Demissie, Serkalem; Duque, Gustavo; Maurano, Matthew T; Kiel, Douglas P; Hsu, Yi-Hsiang; C J van der Eerden, Bram; Ackert-Bicknell, Cheryl; Reppe, Sjur; Gautvik, Kaare M; Raastad, Truls; Karasik, David; van de Peppel, Jeroen; Jaddoe, Vincent W V; Uitterlinden, André G; Tobias, Jonathan H; Grant, Struan F A; Bagos, Pantelis G; Evans, David M; Rivadeneira, Fernando

    2017-07-25

    Bone mineral density is known to be a heritable, polygenic trait whereas genetic variants contributing to lean mass variation remain largely unknown. We estimated the shared SNP heritability and performed a bivariate GWAS meta-analysis of total-body lean mass (TB-LM) and total-body less head bone mineral density (TBLH-BMD) regions in 10,414 children. The estimated SNP heritability is 43% (95% CI: 34-52%) for TBLH-BMD, and 39% (95% CI: 30-48%) for TB-LM, with a shared genetic component of 43% (95% CI: 29-56%). We identify variants with pleiotropic effects in eight loci, including seven established bone mineral density loci: WNT4, GALNT3, MEPE, CPED1/WNT16, TNFSF11, RIN3, and PPP6R3/LRP5. Variants in the TOM1L2/SREBF1 locus exert opposing effects TB-LM and TBLH-BMD, and have a stronger association with the former trait. We show that SREBF1 is expressed in murine and human osteoblasts, as well as in human muscle tissue. This is the first bivariate GWAS meta-analysis to demonstrate genetic factors with pleiotropic effects on bone mineral density and lean mass.Bone mineral density and lean skeletal mass are heritable traits. Here, Medina-Gomez and colleagues perform bivariate GWAS analyses of total body lean mass and bone mass density in children, and show genetic loci with pleiotropic effects on both traits.

  20. Effects of body habitus on internal radiation dose calculations using the 5-year-old anthropomorphic male models.

    PubMed

    Xie, Tianwu; Kuster, Niels; Zaidi, Habib

    2017-07-13

    Computational phantoms are commonly used in internal radiation dosimetry to assess the amount and distribution pattern of energy deposited in various parts of the human body from different internal radiation sources. Radiation dose assessments are commonly performed on predetermined reference computational phantoms while the argument for individualized patient-specific radiation dosimetry exists. This study aims to evaluate the influence of body habitus on internal dosimetry and to quantify the uncertainties in dose estimation correlated with the use of fixed reference models. The 5-year-old IT'IS male phantom was modified to match target anthropometric parameters, including body weight, body height and sitting height/stature ratio (SSR), determined from reference databases, thus enabling the creation of 125 5-year-old habitus-dependent male phantoms with 10th, 25th, 50th, 75th and 90th percentile body morphometries. We evaluated the absorbed fractions and the mean absorbed dose to the target region per unit cumulative activity in the source region (S-values) of F-18 in 46 source regions for the generated 125 anthropomorphic 5-year-old hybrid male phantoms using the Monte Carlo N-Particle eXtended general purpose Monte Carlo transport code and calculated the absorbed dose and effective dose of five 18 F-labelled radiotracers for children of various habitus. For most organs, the S-value of F-18 presents stronger statistical correlations with body weight, standing height and sitting height than BMI and SSR. The self-absorbed fraction and self-absorbed S-values of F-18 and the absorbed dose and effective dose of 18 F-labelled radiotracers present with the strongest statistical correlations with body weight. For 18 F-Amino acids, 18 F-Brain receptor substances, 18 F-FDG, 18 F-L-DOPA and 18 F-FBPA, the mean absolute effective dose differences between phantoms of different habitus and fixed reference models are 11.4%, 11.3%, 10.8%, 13.3% and 11.4%, respectively. Total body weight, standing height and sitting height have considerable effects on human internal dosimetry. Radiation dose calculations for individual subjects using the most closely matched habitus-dependent computational phantom should be considered as an alternative to improve the accuracy of the estimates.

  1. Effects of body habitus on internal radiation dose calculations using the 5-year-old anthropomorphic male models

    NASA Astrophysics Data System (ADS)

    Xie, Tianwu; Kuster, Niels; Zaidi, Habib

    2017-08-01

    Computational phantoms are commonly used in internal radiation dosimetry to assess the amount and distribution pattern of energy deposited in various parts of the human body from different internal radiation sources. Radiation dose assessments are commonly performed on predetermined reference computational phantoms while the argument for individualized patient-specific radiation dosimetry exists. This study aims to evaluate the influence of body habitus on internal dosimetry and to quantify the uncertainties in dose estimation correlated with the use of fixed reference models. The 5-year-old IT’IS male phantom was modified to match target anthropometric parameters, including body weight, body height and sitting height/stature ratio (SSR), determined from reference databases, thus enabling the creation of 125 5-year-old habitus-dependent male phantoms with 10th, 25th, 50th, 75th and 90th percentile body morphometries. We evaluated the absorbed fractions and the mean absorbed dose to the target region per unit cumulative activity in the source region (S-values) of F-18 in 46 source regions for the generated 125 anthropomorphic 5-year-old hybrid male phantoms using the Monte Carlo N-Particle eXtended general purpose Monte Carlo transport code and calculated the absorbed dose and effective dose of five 18F-labelled radiotracers for children of various habitus. For most organs, the S-value of F-18 presents stronger statistical correlations with body weight, standing height and sitting height than BMI and SSR. The self-absorbed fraction and self-absorbed S-values of F-18 and the absorbed dose and effective dose of 18F-labelled radiotracers present with the strongest statistical correlations with body weight. For 18F-Amino acids, 18F-Brain receptor substances, 18F-FDG, 18F-L-DOPA and 18F-FBPA, the mean absolute effective dose differences between phantoms of different habitus and fixed reference models are 11.4%, 11.3%, 10.8%, 13.3% and 11.4%, respectively. Total body weight, standing height and sitting height have considerable effects on human internal dosimetry. Radiation dose calculations for individual subjects using the most closely matched habitus-dependent computational phantom should be considered as an alternative to improve the accuracy of the estimates.

  2. The development of a post-mortem interval estimation for human remains found on land in the Netherlands.

    PubMed

    Gelderman, H T; Boer, L; Naujocks, T; IJzermans, A C M; Duijst, W L J M

    2018-05-01

    The decomposition process of human remains can be used to estimate the post-mortem interval (PMI), but decomposition varies due to many factors. Temperature is believed to be the most important and can be connected to decomposition by using the accumulated degree days (ADD). The aim of this research was to develop a decomposition scoring method and to develop a formula to estimate the PMI by using the developed decomposition scoring method and ADD.A decomposition scoring method and a Book of Reference (visual resource) were made. Ninety-one cases were used to develop a method to estimate the PMI. The photographs were scored using the decomposition scoring method. The temperature data was provided by the Royal Netherlands Meteorological Institute. The PMI was estimated using the total decomposition score (TDS) and using the TDS and ADD. The latter required an additional step, namely to calculate the ADD from the finding date back until the predicted day of death.The developed decomposition scoring method had a high interrater reliability. The TDS significantly estimates the PMI (R 2  = 0.67 and 0.80 for indoor and outdoor bodies, respectively). When using the ADD, the R 2 decreased to 0.66 and 0.56.The developed decomposition scoring method is a practical method to measure decomposition for human remains found on land. The PMI can be estimated using this method, but caution is advised in cases with a long PMI. The ADD does not account for all the heat present in a decomposing remain and is therefore a possible bias.

  3. Local air gap thickness and contact area models for realistic simulation of human thermo-physiological response

    NASA Astrophysics Data System (ADS)

    Psikuta, Agnes; Mert, Emel; Annaheim, Simon; Rossi, René M.

    2018-02-01

    To evaluate the quality of new energy-saving and performance-supporting building and urban settings, the thermal sensation and comfort models are often used. The accuracy of these models is related to accurate prediction of the human thermo-physiological response that, in turn, is highly sensitive to the local effect of clothing. This study aimed at the development of an empirical regression model of the air gap thickness and the contact area in clothing to accurately simulate human thermal and perceptual response. The statistical model predicted reliably both parameters for 14 body regions based on the clothing ease allowances. The effect of the standard error in air gap prediction on the thermo-physiological response was lower than the differences between healthy humans. It was demonstrated that currently used assumptions and methods for determination of the air gap thickness can produce a substantial error for all global, mean, and local physiological parameters, and hence, lead to false estimation of the resultant physiological state of the human body, thermal sensation, and comfort. Thus, this model may help researchers to strive for improvement of human thermal comfort, health, productivity, safety, and overall sense of well-being with simultaneous reduction of energy consumption and costs in built environment.

  4. A Longitudinal Study on Human Outdoor Decomposition in Central Texas.

    PubMed

    Suckling, Joanna K; Spradley, M Katherine; Godde, Kanya

    2016-01-01

    The development of a methodology that estimates the postmortem interval (PMI) from stages of decomposition is a goal for which forensic practitioners strive. A proposed equation (Megyesi et al. 2005) that utilizes total body score (TBS) and accumulated degree days (ADD) was tested using longitudinal data collected from human remains donated to the Forensic Anthropology Research Facility (FARF) at Texas State University-San Marcos. Exact binomial tests examined the rate of the equation to successfully predict ADD. Statistically significant differences were found between ADD estimated by the equation and the observed value for decomposition stage. Differences remained significant after carnivore scavenged donations were removed from analysis. Low success rates for the equation to predict ADD from TBS and the wide standard errors demonstrate the need to re-evaluate the use of this equation and methodology for PMI estimation in different environments; rather, multivariate methods and equations should be derived that are environmentally specific. © 2015 American Academy of Forensic Sciences.

  5. Origins and early development of human body knowledge.

    PubMed

    Slaughter, Virginia; Heron, Michelle

    2004-01-01

    As a knowable object, the human body is highly complex. Evidence from several converging lines of research, including psychological studies, neuroimaging and clinical neuropsychology, indicates that human body knowledge is widely distributed in the adult brain, and is instantiated in at least three partially independent levels of representation. Sensorimotor body knowledge is responsible for on-line control and movement of one's own body and may also contribute to the perception of others' moving bodies; visuo-spatial body knowledge specifies detailed structural descriptions of the spatial attributes of the human body; and lexical-semantic body knowledge contains language-based knowledge about the human body. In the first chapter of this Monograph, we outline the evidence for these three hypothesized levels of human body knowledge, then review relevant literature on infants' and young children's human body knowledge in terms of the three-level framework. In Chapters II and III, we report two complimentary series of studies that specifically investigate the emergence of visuo-spatial body knowledge in infancy. Our technique is to compare infants'responses to typical and scrambled human bodies, in order to evaluate when and how infants acquire knowledge about the canonical spatial layout of the human body. Data from a series of visual habituation studies indicate that infants first discriminate scrambled from typical human body picture sat 15 to 18 months of age. Data from object examination studies similarly indicate that infants are sensitive to violations of three-dimensional human body stimuli starting at 15-18 months of age. The overall pattern of data supports several conclusions about the early development of human body knowledge: (a) detailed visuo-spatial knowledge about the human body is first evident in the second year of life, (b) visuo-spatial knowledge of human faces and human bodies are at least partially independent in infancy and (c) infants' initial visuo-spatial human body representations appear to be highly schematic, becoming more detailed and specific with development. In the final chapter, we explore these conclusions and discuss how levels of body knowledge may interact in early development.

  6. Estimated human absorbed dose of a new (153)Sm bone seeking agent based on biodistribution data in mice: Comparison with (153)Sm-EDTMP.

    PubMed

    Yousefnia, Hassan; Zolghadri, Samaneh

    2015-11-01

    The main goal in radiotherapy is to deliver the absorbed dose within the target organs in highest possible amount, while the absorbed dose of the other organs, especially the critical organs, should be kept as low as possible. In this work, the absorbed dose to human organs for a new (153)Sm bone-seeking agent was investigated. (153)Sm-(4-{[(bis(phosphonomethyl))carbamoyl]methyl}-7,10-bis(carboxymethyl)-1,4,7,10-tetraazacyclododec-1-yl) acetic acid ((153)Sm-BPAMD) complex was successfully prepared. The biodistribution of the complex was investigated in male Syrian mice up to 48 h post injection. The human absorbed dose of the complex was estimated based on the biodistribution data of the mice by radiation absorbed dose assessment resource (RADAR) method. The target to non-target absorbed dose ratios for (153)Sm-BPAMD were compared with these ratios for (153)Sm-EDTMP. The highest absorbed dose for (153)Sm-BPAMD was observed in bone surface with 5.828 mGy/MBq. The dose ratios of the bone surface to the red marrow and to the total body for (153)Sm-BPAMD were 5.3 and 20.0, respectively, while these ratios for (153)Sm-EDTMP were 4.4 and 18.3, respectively. This means, for a given dose to the bone surface as the target organ, the red marrow (as the main critical organ) and the total body would receive lesser absorbed dose in the case of (153)Sm-BPAMD. Generally, the human absorbed dose estimation of (153)Sm-BPAMD indicated that all other tissues approximately received insignificant absorbed dose in comparison with bone surface and therefore can be regarded as a new potential agent for bone pain palliation therapy. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Body Segment Differences in Surface Area, Skin Temperature and 3D Displacement and the Estimation of Heat Balance during Locomotion in Hominins

    PubMed Central

    Cross, Alan; Collard, Mark; Nelson, Andrew

    2008-01-01

    The conventional method of estimating heat balance during locomotion in humans and other hominins treats the body as an undifferentiated mass. This is problematic because the segments of the body differ with respect to several variables that can affect thermoregulation. Here, we report a study that investigated the impact on heat balance during locomotion of inter-segment differences in three of these variables: surface area, skin temperature and rate of movement. The approach adopted in the study was to generate heat balance estimates with the conventional method and then compare them with heat balance estimates generated with a method that takes into account inter-segment differences in surface area, skin temperature and rate of movement. We reasoned that, if the hypothesis that inter-segment differences in surface area, skin temperature and rate of movement affect heat balance during locomotion is correct, the estimates yielded by the two methods should be statistically significantly different. Anthropometric data were collected on seven adult male volunteers. The volunteers then walked on a treadmill at 1.2 m/s while 3D motion capture cameras recorded their movements. Next, the conventional and segmented methods were used to estimate the volunteers' heat balance while walking in four ambient temperatures. Lastly, the estimates produced with the two methods were compared with the paired t-test. The estimates of heat balance during locomotion yielded by the two methods are significantly different. Those yielded by the segmented method are significantly lower than those produced by the conventional method. Accordingly, the study supports the hypothesis that inter-segment differences in surface area, skin temperature and rate of movement impact heat balance during locomotion. This has important implications not only for current understanding of heat balance during locomotion in hominins but also for how future research on this topic should be approached. PMID:18560580

  8. Body segment differences in surface area, skin temperature and 3D displacement and the estimation of heat balance during locomotion in hominins.

    PubMed

    Cross, Alan; Collard, Mark; Nelson, Andrew

    2008-06-18

    The conventional method of estimating heat balance during locomotion in humans and other hominins treats the body as an undifferentiated mass. This is problematic because the segments of the body differ with respect to several variables that can affect thermoregulation. Here, we report a study that investigated the impact on heat balance during locomotion of inter-segment differences in three of these variables: surface area, skin temperature and rate of movement. The approach adopted in the study was to generate heat balance estimates with the conventional method and then compare them with heat balance estimates generated with a method that takes into account inter-segment differences in surface area, skin temperature and rate of movement. We reasoned that, if the hypothesis that inter-segment differences in surface area, skin temperature and rate of movement affect heat balance during locomotion is correct, the estimates yielded by the two methods should be statistically significantly different. Anthropometric data were collected on seven adult male volunteers. The volunteers then walked on a treadmill at 1.2 m/s while 3D motion capture cameras recorded their movements. Next, the conventional and segmented methods were used to estimate the volunteers' heat balance while walking in four ambient temperatures. Lastly, the estimates produced with the two methods were compared with the paired t-test. The estimates of heat balance during locomotion yielded by the two methods are significantly different. Those yielded by the segmented method are significantly lower than those produced by the conventional method. Accordingly, the study supports the hypothesis that inter-segment differences in surface area, skin temperature and rate of movement impact heat balance during locomotion. This has important implications not only for current understanding of heat balance during locomotion in hominins but also for how future research on this topic should be approached.

  9. [Trans-uranium elements in food products (review)].

    PubMed

    Vasilenko, I Ia

    1994-01-01

    The data of Russian and foreign authors concerning of level environmental contamination and migration of transuranic elements in food chains, metabolism and biological danger of nuclides entering in human body with foods are reviewed. A level of radionuclide load of population and doses of radiation are discussed and the danger is estimated. The doses of radiation from radionuclide ingestion are lower than level of allowed radiation safety standards.

  10. Burn Injury Assessment Tool with Morphable 3D Human Body Models

    DTIC Science & Technology

    2017-04-21

    waist, arms and legs measurements) as stored in most anthropometry databases . To improve on bum area estimations, the bum tool will allow the user to...different algorithm for morphing that relies on searching of an extensive anthropometric database , which is created from thousands of randomly...interpolation methods are required. Develop Patient Database : Patient data entered (name, gender, age, anthropometric measurements), collected (photographic

  11. Neurophysiological Estimates of Human Performance Capabilities in Aerospace Systems

    DTIC Science & Technology

    1975-01-27

    effects on the visual system (in lateral geniculate bodies and optic cortex) depending on the frequency of auditory stimulation. 27 SECTION VI...of spa- tial positions. Correct responses were rewarded with food. EEG activity was recorded in the hippocampus, hypothalamus and lateral geniculate ...movement or an object movement reduce transmission of visual information through the lateral geniculate nucleus. This may be a mechanism for saccadic

  12. How well does the standard body mass index or variations with a different exponent predict human lifespan?

    PubMed

    Foster, Dean; Karloff, Howard; Shirley, Kenneth E

    2016-02-01

    The objective was twofold: (1) to estimate for each individual the body mass index (BMI) which is associated with the lowest risk of death, and (2) to study variants of the BMI formula to determine which gives the best predictions of death. Treating BMI = mass/height(2) as a continuous variable and estimating its interaction effects with several other variables, this study analyzed the NIH-AARP study data set of approximately 566,000 individuals and fit Cox proportional hazards models to the survival times. For each individual, a "personalized optimal BMI," the BMI for that individual which, according to the model, is associated with the lowest risk of death, is estimated. The average personalized optimal BMI is approximately 26, which is in the current "overweight" category. In fact, mass/height is a better predictor of death on the data set than BMI itself. The model suggests that an individual's "optimal" BMI depends on his or her features; "one-size-fits-all" recommendations may be not best. © 2016 The Obesity Society.

  13. Human spatial orientation in the pitch dimension

    NASA Technical Reports Server (NTRS)

    Cohen, M. M.; Larson, C. A.

    1974-01-01

    Two experiments were conducted. In Experiment I, each of eight Ss attempted to place himself at 13 different goal orientations between prone and supine. Deviations of achieved body pitch angles from goal orientations were determined. In Experiment II, each of eight Ss attempted to align a visual target with his morphological horizon while he was placed at each of the 13 goal orientations. Changes in settings of the target were examined. Results indicate that Ss underestimate body pitch when they are tilted less than 60 deg backward or forward from the vertical, overestimate body pitch when they are nearly prone, and accurately estimate body pitch when they are nearly supine. In contrast, Ss set the visual target maximally above the morphological horizon when they are tilted 30 deg forward from the vertical. The findings are discussed in terms of common and different physiological mechanism that may underlie judgments of these types.

  14. Age-related factors in the relationship between foot measurements and living stature and body weight.

    PubMed

    Atamturk, Derya; Duyar, Izzet

    2008-11-01

    The measurements of feet and footprints are especially important in forensic identification, as they have been used to predict the body height and weight of victims or suspects. It can be observed that the subjects of forensic-oriented studies are generally young adults. That is to say, researchers rarely take into consideration the body's proportional changes with age. Hence, the aim of this study is to generate equations which take age and sex into consideration, when stature and body weight are estimated from foot and footprints dimensions. With this aim in mind, we measured the stature, body weight, foot length and breadth, heel breadth, footprint length and breadth, and footprint heel breadth of 516 volunteers (253 males and 263 females) aged between 17.6 and 82.9 years using standard measurement techniques. The sample population was divided randomly into two groups. Group 1, the study group, consisted of 80% of the sample (n = 406); the remaining 20% were assigned to the cross-validation group or Group 2 (n = 110). In the first stage of the study, we produced equations for estimating stature and weight using a stepwise regression technique. Then, their reliability was tested on Group 2 members. Statistical analyses showed that the ratios of foot dimensions to stature and body weight change considerably with age and sex. Consequently, the regression equations which include these variables yielded more reliable results. Our results indicated that age and sex should be taken into consideration when predicting human body height and weight for forensic purposes.

  15. Cuff-Free Blood Pressure Estimation Using Pulse Transit Time and Heart Rate.

    PubMed

    Wang, Ruiping; Jia, Wenyan; Mao, Zhi-Hong; Sclabassi, Robert J; Sun, Mingui

    2014-10-01

    It has been reported that the pulse transit time (PTT), the interval between the peak of the R-wave in electrocardiogram (ECG) and the fingertip photoplethysmogram (PPG), is related to arterial stiffness, and can be used to estimate the systolic blood pressure (SBP) and diastolic blood pressure (DBP). This phenomenon has been used as the basis to design portable systems for continuously cuff-less blood pressure measurement, benefiting numerous people with heart conditions. However, the PTT-based blood pressure estimation may not be sufficiently accurate because the regulation of blood pressure within the human body is a complex, multivariate physiological process. Considering the negative feedback mechanism in the blood pressure control, we introduce the heart rate (HR) and the blood pressure estimate in the previous step to obtain the current estimate. We validate this method using a clinical database. Our results show that the PTT, HR and previous estimate reduce the estimated error significantly when compared to the conventional PTT estimation approach (p<0.05).

  16. Differences between the most used equations in BAT-human studies to estimate parameters of skin temperature in young lean men.

    PubMed

    Martinez-Tellez, Borja; Sanchez-Delgado, Guillermo; Acosta, Francisco M; Alcantara, Juan M A; Boon, Mariëtte R; Rensen, Patrick C N; Ruiz, Jonatan R

    2017-09-05

    Cold exposure is necessary to activate human brown adipose tissue (BAT), resulting in heat production. Skin temperature is an indirect measure to monitor the body's reaction to cold. The aim of this research was to study whether the most used equations to estimate parameters of skin temperature in BAT-human studies measure the same values of temperature in young lean men (n = 11: 23.4 ± 0.5 years, fat mass: 19.9 ± 1.2%). Skin temperature was measured with 26 ibuttons at 1-minute intervals in warm and cold room conditions. We used 12 equations to estimate parameters of mean, proximal, and distal skin temperature as well as skin temperature gradients. Data were analysed with Temperatus software. Significant differences were found across equations to measure the same parameters of skin temperature in warm and cold room conditions, hampering comparison across studies. Based on these findings, we suggest to use a set of 14 ibuttons at anatomical positions reported by ISO STANDARD 9886:2004 plus five ibuttons placed on the right supraclavicular fossa, right middle clavicular bone, right middle upper forearm, right top of forefinger, and right upper chest.

  17. [Survival Strategies of Aspergillus in the Human Body].

    PubMed

    Tashiro, Masato; Izumikawa, Koichi

    2017-01-01

     The human body is a hostile environment for Aspergillus species, which originally live outside the human body. There are lots of elimination mechanisms against Aspergillus inhaled into the human body, such as high body temperature, soluble lung components, mucociliary clearance mechanism, or responses of phagocytes. Aspergillus fumigatus, which is the primary causative agent of human infections among the human pathogenic species of Aspergillus, defend itself from the hostile human body environment by various mechanisms, such as thermotolerance, mycotoxin production, and characteristic morphological features. Here we review mechanisms of defense in Aspergillus against elimination from the human body.

  18. Computational dosimetry for grounded and ungrounded human models due to contact current

    NASA Astrophysics Data System (ADS)

    Chan, Kwok Hung; Hattori, Junya; Laakso, Ilkka; Hirata, Akimasa; Taki, Masao

    2013-08-01

    This study presents the computational dosimetry of contact currents for grounded and ungrounded human models. The uncertainty of the quasi-static (QS) approximation of the in situ electric field induced in a grounded/ungrounded human body due to the contact current is first estimated. Different scenarios of cylindrical and anatomical human body models are considered, and the results are compared with the full-wave analysis. In the QS analysis, the induced field in the grounded cylindrical model is calculated by the QS finite-difference time-domain (QS-FDTD) method, and compared with the analytical solution. Because no analytical solution is available for the grounded/ungrounded anatomical human body model, the results of the QS-FDTD method are then compared with those of the conventional FDTD method. The upper frequency limit for the QS approximation in the contact current dosimetry is found to be 3 MHz, with a relative local error of less than 10%. The error increases above this frequency, which can be attributed to the neglect of the displacement current. The QS or conventional FDTD method is used for the dosimetry of induced electric field and/or specific absorption rate (SAR) for a contact current injected into the index finger of a human body model in the frequency range from 10 Hz to 100 MHz. The in situ electric fields or SAR are compared with the basic restrictions in the international guidelines/standards. The maximum electric field or the 99th percentile value of the electric fields appear not only in the fat and muscle tissues of the finger, but also around the wrist, forearm, and the upper arm. Some discrepancies are observed between the basic restrictions for the electric field and SAR and the reference levels for the contact current, especially in the extremities. These discrepancies are shown by an equation that relates the current density, tissue conductivity, and induced electric field in the finger with a cross-sectional area of 1 cm2.

  19. Application of isotope dilution technique in vitamin A nutrition.

    PubMed

    Wasantwisut, Emorn

    2002-09-01

    The isotope dilution technique involving deuterated retinol has been developed to quantitatively estimate total body reserves of vitamin A in humans. The technique provided good estimates in comparison to hepatic vitamin A concentrations in Bangladeshi surgical patients. Kinetic studies in the United States, Bangladesh, and Guatemala indicated the mean equilibration time of 17 to 20 days irrespective of the size of hepatic reserves. Due to the controversy surrounding the efficacy of a carotene-rich diet on improvement of vitamin A status, the isotope dilution technique was proposed to pursue this research question further (IAEA's coordinated research program). In the Philippines, schoolchildren with low serum retinol concentrations showed significant improvement in total body vitamin A stores following intake of carotene-rich foods (orange fruits and vegetables), using a three-day deuterated-retinol-dilution procedure. When Chinese kindergarten children were fed green and yellow vegetables during the winter, their total body vitamin A stores were sustained as compared to a steady decline of vitamin A stores in the control children. Likewise, daily consumption of purified beta-carotene or diet rich in provitamin A carotenoids were shown to prevent a loss in total body vitamin A stores among Thai lactating women during the rice-planting season. These studies demonstrate potentials of the isotope dilution technique to evaluate the impact of provitamin A carotenoid intervention programs.

  20. Biodistribution and Radiation Dosimetry of the Integrin Marker 64Cu-BaBaSar-RGD2 Determined from Whole-Body PET/CT in a Non-Human Primate

    NASA Astrophysics Data System (ADS)

    Liu, Shuanglong; Vorobyova, Ivetta; Park, Ryan; Conti, Peter S.

    2017-10-01

    Introduction: 64Cu-BaBaSar-RGD2 is a positron emission radiotracer taken up by integrin αvβ3, which is overexpressed in many malignancies. The aim of this study was to evaluate the biodistribution of 64Cu-BaBaSar-RGD2 in a non-human primate with positron emission tomography and to estimate the absorbed doses in major organs for human. Materials and methods: Whole-body PET imaging was done in a Siemens Biograph scanner in a male macaque monkey. After an i.v. injection of 13.1–19.7 MBq/kg of 64Cu-BaBaSar-RGD2, whole body scan was collected for a total duration of 180 min. Attenuation and scatter corrections were applied to reconstruction of the whole-body emission scan. After image reconstruction, three-dimensional volumes of interest (VOI) were hand-drawn on the PET transaxial or coronal slices of the frame where the organ was most conspicuous. Time-activity curves for each VOI were obtained, and residence time of each organ was calculated by integration of the time-activity curves. Human absorbed doses were estimated using the standard human model in OLINDA/EXM software. Results: Injection of 64Cu-BaBaSar-RGD2 was well tolerated in the macaque monkey, with no serious tracer-related adverse events observed. 64Cu-BaBaSar-RGD2 was cleared rapidly from the blood pool, with a 12.1-min biological half-time. Increased 64Cu-BaBaSar-RGD2 uptake was observed in the kidneys, and bladder, with mean percentage injected dose (ID%) values at 1 h after injection approximately 35.50 ± 6.47 and 36.89 ± 5.48, respectively. The calculated effective dose was 15.30 ± 2.21 µSv/MBq, and the kidneys had the highest absorbed dose at 108.43 ± 16.41 µGy/MBq using the non-voiding model. For an injected activity of 925 MBq 64Cu for human, the effective dose would be 14.2 ± 2.1 mSv. Discussion: Due to the limitation of the monkey number, we evaluated 64Cu-BaBaSar-RGD2 in the same monkey of three imaging sessions. Measured absorbed doses and effective doses of 64Cu-BaBaSar-RGD2 are comparable to other reported RGD-derived radiopharmaceuticals labeled with 64Cu and 18F. Therefore, 64Cu-BaBaSar-RGD2 can be safely injected into humans for studying integrin αvβ3 expression non-invasively.

  1. Human environmental and occupational exposures to boric acid: reconciliation with experimental reproductive toxicity data.

    PubMed

    Bolt, Hermann M; Başaran, Nurşen; Duydu, Yalçın

    2012-01-01

    The reproductive toxicity of boric acid and borates is a matter of current regulatory concern. Based on experimental studies in rats, no-observed-adverse-effect levels (NOAELs) were found to be 17.5 mg boron (B)/kg body weight (b.w.) for male fertility and 9.6 mg B/kg b.w. for developmental toxicity. Recently, occupational human field studies in highly exposed cohorts were reported from China and Turkey, with both studies showing negative results regarding male reproduction. A comparison of the conditions of these studies with the experimental NOAEL conditions are based on reported B blood levels, which is clearly superior to a scaling according to estimated B exposures. A comparison of estimated daily B exposure levels and measured B blood levels confirms the preference of biomonitoring data for a comparison of human field studies. In general, it appears that high environmental exposures to B are lower than possible high occupational exposures. The comparison reveals no contradiction between human and experimental reproductive toxicity data. It clearly appears that human B exposures, even in the highest exposed cohorts, are too low to reach the blood (and target tissue) concentrations that would be required to exert adverse effects on reproductive functions.

  2. Fly pupae and puparia as potential contaminants of forensic entomology samples from sites of body discovery.

    PubMed

    Archer, M S; Elgar, M A; Briggs, C A; Ranson, D L

    2006-11-01

    Fly pupae and puparia may contaminate forensic entomology samples at death scenes if they have originated not from human remains but from animal carcasses or other decomposing organic material. These contaminants may erroneously lengthen post-mortem interval estimates if no pupae or puparia are genuinely associated with the body. Three forensic entomology case studies are presented, in which contamination either occurred or was suspected. In the first case, blow fly puparia collected near the body were detected as contaminants because the species was inactive both when the body was found and when the deceased was last sighted reliably. The second case illustrates that contamination may be suspected at particularly squalid death scenes because of the likely presence of carcasses or organic material. The third case involves the presence at the body discovery site of numerous potentially contaminating animal carcasses. Soil samples were taken along transects to show that pupae and puparia were clustered around their probable sources.

  3. Skeletal Correlates for Body Mass Estimation in Modern and Fossil Flying Birds

    PubMed Central

    Field, Daniel J.; Lynner, Colton; Brown, Christian; Darroch, Simon A. F.

    2013-01-01

    Scaling relationships between skeletal dimensions and body mass in extant birds are often used to estimate body mass in fossil crown-group birds, as well as in stem-group avialans. However, useful statistical measurements for constraining the precision and accuracy of fossil mass estimates are rarely provided, which prevents the quantification of robust upper and lower bound body mass estimates for fossils. Here, we generate thirteen body mass correlations and associated measures of statistical robustness using a sample of 863 extant flying birds. By providing robust body mass regressions with upper- and lower-bound prediction intervals for individual skeletal elements, we address the longstanding problem of body mass estimation for highly fragmentary fossil birds. We demonstrate that the most precise proxy for estimating body mass in the overall dataset, measured both as coefficient determination of ordinary least squares regression and percent prediction error, is the maximum diameter of the coracoid’s humeral articulation facet (the glenoid). We further demonstrate that this result is consistent among the majority of investigated avian orders (10 out of 18). As a result, we suggest that, in the majority of cases, this proxy may provide the most accurate estimates of body mass for volant fossil birds. Additionally, by presenting statistical measurements of body mass prediction error for thirteen different body mass regressions, this study provides a much-needed quantitative framework for the accurate estimation of body mass and associated ecological correlates in fossil birds. The application of these regressions will enhance the precision and robustness of many mass-based inferences in future paleornithological studies. PMID:24312392

  4. Bioconcentration factors and potential human health risks of heavy metals in cultivated Lentinus edodes in Chengdu, People's Republic of China.

    PubMed

    Pei, Donghui; Xie, Han; Song, Haihai; Xu, Heng; Wu, Yumeng

    2015-02-01

    Lentinus edodes is one of the most popular edible mushrooms in the market. However, it contains heavy metals that are poisonous to humans even at trace concentrations. The concentrations and bioconcentration factors of five heavy metals in cultivated L. edodes in Chengdu were studied, and the potential health risks to local residents associated with the cultivated L. edodes consumption were evaluated. Total concentrations of cadmium (Cd), lead (Pb), chromium (Cr), arsenic (As), and mercury were determined in the fruiting bodies and the substrate from three agricultural areas. Fruiting bodies samples were collected at different growing times (2, 4, 6, and 8 days). The bioconcentration factors of heavy metals from the substrate to the fruiting bodies were estimated, and the potential health risks of local L. edodes were assessed. Because antioxidant enzymes can resist the creation of reactive oxygen species and defend against heavy metals, the activities of three antioxidant enzymes (superoxide dismutase, catalase, and peroxidase) in the fruiting bodies were also determined. A gradual change in heavy metal concentrations occurred across the growing time of the fruiting bodies. Cd transferred from the substrate to the fruiting bodies in larger concentrations than did Pb, Cr, and As. However, Chengdu residents were not exposed to significant health risks associated with consumption of local L. edodes. Nevertheless, more attention should be focused on children because of their higher sensitivity to metal pollutants.

  5. Comparison of oral bioavailability of benzo[a]pyrene in soils using rat and swine and the implications for human health risk assessment.

    PubMed

    Duan, Luchun; Naidu, Ravi; Liu, Yanju; Dong, Zhaomin; Mallavarapu, Megharaj; Herde, Paul; Kuchel, Tim; Semple, Kirk T

    2016-09-01

    There are many uncertainties concerning variations in benzo[a]pyrene (B[a]P) soil guidelines protecting human health based on carcinogenic data obtained in animal studies. Although swine is recognised as being much more representative of the human child in terms of body size, gut physiology and genetic profile the rat/mice model is commonly used in practice. We compare B[a]P bioavailability using a rat model to that estimated in a swine model, to investigate the correlation between these two animal models. This may help reduce uncertainty in applying bioavailability to human health risk assessment. Twelve spiked soil samples and a spiked silica sand (reference material) were dosed to rats in parallel with a swine study. B[a]P bioavailability was estimated by the area under the plasma B[a]P concentration-time curve (AUC) and faecal excretion as well in the rats. Direct comparison between the two animal models was made for: firstly, relative bioavailability (RB) using AUC assay; and secondly, the two assays in the rat model. Both AUC and faecal excretion assays showed linear dose-response for the reference material. However, absolute bioavailability was significantly higher when using faecal excretion assay (p<0.001). In aged soils faecal excretion estimated based on solvent extraction was not accurate due to the form of non-extractable fraction through ageing. A significant correlation existed between the two models using RB for soil samples (RBrat=0.26RBswine+17.3, R(2)=0.70, p<0.001), despite the regression slope coefficient revealing that the rat model would underestimate RB by about one quarter compared to using swine. In the comparison employed in this study, an interspecies difference of four in RB using AUC assay was identified between the rat and swine models regarding pharmacokinetic differences, which supported the body weight scaling method recommended by US EPA. Future research should focus on the carcinogenic competency (pharmacodynamics) used in experiment animals and humans. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Estimation of Circadian Body Temperature Rhythm Based on Heart Rate in Healthy, Ambulatory Subjects.

    PubMed

    Sim, Soo Young; Joo, Kwang Min; Kim, Han Byul; Jang, Seungjin; Kim, Beomoh; Hong, Seungbum; Kim, Sungwan; Park, Kwang Suk

    2017-03-01

    Core body temperature is a reliable marker for circadian rhythm. As characteristics of the circadian body temperature rhythm change during diverse health problems, such as sleep disorder and depression, body temperature monitoring is often used in clinical diagnosis and treatment. However, the use of current thermometers in circadian rhythm monitoring is impractical in daily life. As heart rate is a physiological signal relevant to thermoregulation, we investigated the feasibility of heart rate monitoring in estimating circadian body temperature rhythm. Various heart rate parameters and core body temperature were simultaneously acquired in 21 healthy, ambulatory subjects during their routine life. The performance of regression analysis and the extended Kalman filter on daily body temperature and circadian indicator (mesor, amplitude, and acrophase) estimation were evaluated. For daily body temperature estimation, mean R-R interval (RRI), mean heart rate (MHR), or normalized MHR provided a mean root mean square error of approximately 0.40 °C in both techniques. The mesor estimation regression analysis showed better performance than the extended Kalman filter. However, the extended Kalman filter, combined with RRI or MHR, provided better accuracy in terms of amplitude and acrophase estimation. We suggest that this noninvasive and convenient method for estimating the circadian body temperature rhythm could reduce discomfort during body temperature monitoring in daily life. This, in turn, could facilitate more clinical studies based on circadian body temperature rhythm.

  7. Gorilla and Orangutan Brains Conform to the Primate Cellular Scaling Rules: Implications for Human Evolution

    PubMed Central

    Herculano-Houzel, Suzana; Kaas, Jon H.

    2011-01-01

    Gorillas and orangutans are primates at least as large as humans, but their brains amount to about one third of the size of the human brain. This discrepancy has been used as evidence that the human brain is about 3 times larger than it should be for a primate species of its body size. In contrast to the view that the human brain is special in its size, we have suggested that it is the great apes that might have evolved bodies that are unusually large, on the basis of our recent finding that the cellular composition of the human brain matches that expected for a primate brain of its size, making the human brain a linearly scaled-up primate brain in its number of cells. To investigate whether the brain of great apes also conforms to the primate cellular scaling rules identified previously, we determine the numbers of neuronal and other cells that compose the orangutan and gorilla cerebella, use these numbers to calculate the size of the brain and of the cerebral cortex expected for these species, and show that these match the sizes described in the literature. Our results suggest that the brains of great apes also scale linearly in their numbers of neurons like other primate brains, including humans. The conformity of great apes and humans to the linear cellular scaling rules that apply to other primates that diverged earlier in primate evolution indicates that prehistoric Homo species as well as other hominins must have had brains that conformed to the same scaling rules, irrespective of their body size. We then used those scaling rules and published estimated brain volumes for various hominin species to predict the numbers of neurons that composed their brains. We predict that Homo heidelbergensis and Homo neanderthalensis had brains with approximately 80 billion neurons, within the range of variation found in modern Homo sapiens. We propose that while the cellular scaling rules that apply to the primate brain have remained stable in hominin evolution (since they apply to simians, great apes and modern humans alike), the Colobinae and Pongidae lineages favored marked increases in body size rather than brain size from the common ancestor with the Homo lineage, while the Homo lineage seems to have favored a large brain instead of a large body, possibly due to the metabolic limitations to having both. PMID:21228547

  8. Gorilla and orangutan brains conform to the primate cellular scaling rules: implications for human evolution.

    PubMed

    Herculano-Houzel, Suzana; Kaas, Jon H

    2011-01-01

    Gorillas and orangutans are primates at least as large as humans, but their brains amount to about one third of the size of the human brain. This discrepancy has been used as evidence that the human brain is about 3 times larger than it should be for a primate species of its body size. In contrast to the view that the human brain is special in its size, we have suggested that it is the great apes that might have evolved bodies that are unusually large, on the basis of our recent finding that the cellular composition of the human brain matches that expected for a primate brain of its size, making the human brain a linearly scaled-up primate brain in its number of cells. To investigate whether the brain of great apes also conforms to the primate cellular scaling rules identified previously, we determine the numbers of neuronal and other cells that compose the orangutan and gorilla cerebella, use these numbers to calculate the size of the brain and of the cerebral cortex expected for these species, and show that these match the sizes described in the literature. Our results suggest that the brains of great apes also scale linearly in their numbers of neurons like other primate brains, including humans. The conformity of great apes and humans to the linear cellular scaling rules that apply to other primates that diverged earlier in primate evolution indicates that prehistoric Homo species as well as other hominins must have had brains that conformed to the same scaling rules, irrespective of their body size. We then used those scaling rules and published estimated brain volumes for various hominin species to predict the numbers of neurons that composed their brains. We predict that Homo heidelbergensis and Homo neanderthalensis had brains with approximately 80 billion neurons, within the range of variation found in modern Homo sapiens. We propose that while the cellular scaling rules that apply to the primate brain have remained stable in hominin evolution (since they apply to simians, great apes and modern humans alike), the Colobinae and Pongidae lineages favored marked increases in body size rather than brain size from the common ancestor with the Homo lineage, while the Homo lineage seems to have favored a large brain instead of a large body, possibly due to the metabolic limitations to having both. Copyright © 2011 S. Karger AG, Basel.

  9. IMU-to-Segment Assignment and Orientation Alignment for the Lower Body Using Deep Learning

    PubMed Central

    2018-01-01

    Human body motion analysis based on wearable inertial measurement units (IMUs) receives a lot of attention from both the research community and the and industrial community. This is due to the significant role in, for instance, mobile health systems, sports and human computer interaction. In sensor based activity recognition, one of the major issues for obtaining reliable results is the sensor placement/assignment on the body. For inertial motion capture (joint kinematics estimation) and analysis, the IMU-to-segment (I2S) assignment and alignment are central issues to obtain biomechanical joint angles. Existing approaches for I2S assignment usually rely on hand crafted features and shallow classification approaches (e.g., support vector machines), with no agreement regarding the most suitable features for the assignment task. Moreover, estimating the complete orientation alignment of an IMU relative to the segment it is attached to using a machine learning approach has not been shown in literature so far. This is likely due to the high amount of training data that have to be recorded to suitably represent possible IMU alignment variations. In this work, we propose online approaches for solving the assignment and alignment tasks for an arbitrary amount of IMUs with respect to a biomechanical lower body model using a deep learning architecture and windows of 128 gyroscope and accelerometer data samples. For this, we combine convolutional neural networks (CNNs) for local filter learning with long-short-term memory (LSTM) recurrent networks as well as generalized recurrent units (GRUs) for learning time dynamic features. The assignment task is casted as a classification problem, while the alignment task is casted as a regression problem. In this framework, we demonstrate the feasibility of augmenting a limited amount of real IMU training data with simulated alignment variations and IMU data for improving the recognition/estimation accuracies. With the proposed approaches and final models we achieved 98.57% average accuracy over all segments for the I2S assignment task (100% when excluding left/right switches) and an average median angle error over all segments and axes of 2.91° for the I2S alignment task. PMID:29351262

  10. Control of human gait stability through foot placement.

    PubMed

    Bruijn, Sjoerd M; van Dieën, Jaap H

    2018-06-01

    During human walking, the centre of mass (CoM) is outside the base of support for most of the time, which poses a challenge to stabilizing the gait pattern. Nevertheless, most of us are able to walk without substantial problems. In this review, we aim to provide an integrative overview of how humans cope with an underactuated gait pattern. A central idea that emerges from the literature is that foot placement is crucial in maintaining a stable gait pattern. In this review, we explore this idea; we first describe mechanical models and concepts that have been used to predict how foot placement can be used to control gait stability. These concepts, such as for instance the extrapolated CoM concept, the foot placement estimator concept and the capture point concept, provide explicit predictions on where to place the foot relative to the body at each step, such that gait is stabilized. Next, we describe empirical findings on foot placement during human gait in unperturbed and perturbed conditions. We conclude that humans show behaviour that is largely in accordance with the aforementioned concepts, with foot placement being actively coordinated to body CoM kinematics during the preceding step. In this section, we also address the requirements for such control in terms of the sensory information and the motor strategies that can implement such control, as well as the parts of the central nervous system that may be involved. We show that visual, vestibular and proprioceptive information contribute to estimation of the state of the CoM. Foot placement is adjusted to variations in CoM state mainly by modulation of hip abductor muscle activity during the swing phase of gait, and this process appears to be under spinal and supraspinal, including cortical, control. We conclude with a description of how control of foot placement can be impaired in humans, using ageing as a primary example and with some reference to pathology, and we address alternative strategies available to stabilize gait, which include modulation of ankle moments in the stance leg and changes in body angular momentum, such as rapid trunk tilts. Finally, for future research, we believe that especially the integration of consideration of environmental constraints on foot placement with balance control deserves attention. © 2018 The Authors.

  11. Human metabolism and ecological transfer of radioactive caesium: Comparative studies of Chernobyl debris and nuclear weapons fallout, in Southern Sweden and in Bryansk, Russia

    NASA Astrophysics Data System (ADS)

    Raaf, Christopher Leopold

    The whole-body content of radiocaesium was measured in a South-Swedish urban group of people residing in the city of Lund (55.7°N, 13.2°E) between 1960 and 1994. The results from the survey have been analysed in order to estimate the ecological half-time, Teff,eco, of fallout radiocaesium and the aggregate transfer from ground deposition to man in the region. After 1987, the biological half-times, Ts, of 137Cs and 40K in man were also determined in the reference group through whole-body content measurements in combination with 24-hour urine sampling. Relationships between 24-hour urinary excretion and body burden of 137Cs in the group together with data from the literature were then applied to urine samples collected in 1994 and 1995 from adult subjects living in the highly contaminated region of Bryansk, Russia, in order to estimate their average body burden of 137Cs. The equivalent biological half-time for 137Cs in females of the Lund reference group was, on average (+/-1 WSE), 66 +/- 3 d, which agrees with other findings, whereas the value for the males, 81 +/- 4 d, was, on average, significantly lower than what is found in the literature. This is partly explained by the elevated mean age and relatively low mean body muscle mass of the males investigated in the group during the post-Chernobyl study period. The effective ecological half-time for 137Cs from Chernobyl was found to be 1.8 +/- 0.2 y. The aggregate transfer of 137Cs from deposition to mean activity concentration in man was estimated to be 1.7 Bq kg-1/kBq m-2. These vales may be compared with an effective ecological half-time of 1.3 years found in the reference group in the 1960s, and an aggregate transfer factor of 9.8 Bq kg-1/kBq m-2. The average committed effective dose from ingested 137Cs Chernobyl fallout in the study group was estimated to be 0.02 mSv and from the nuclear weapons fallout to 0.20 mSv. The estimates of whole-body content of 137Cs in the Russian subjects obtained through creatinine normalisation of the 137Cs content in urine were, on average, a factor of 2 higher than estimates obtained through a potassium normalisation procedure; 55 +/- 8 (1 SE) kBq for creatinine and 29 +/- 4 (1 SE) kBq for potassium normalisation in the year 1994. This was due to a significant difference in the relationship between the urinary potassium and creatinine concentration between the Swedish and Russian group. The elevated potassium concentration found in the rural Russian subjects indicated a higher dietary intake of potassium, which greatly influences the accuracy and applicability of the potassium normalisation method when estimating body burden of 137Cs through urine assay. It is therefore recommended not to use the potassium normalisation procedure in cases where the daily intake of potassium is unknown. The estimated body burden of 137Cs in the Bryansk group in 1994 corresponds to a contribution to the estimated annual effective dose of 1.8 mSv y-1, which is approximately 200 times greater than the average annual dose received from ingested 137Cs by the subjects of the Lund reference group during the period 1987-1994.

  12. Dietary exposure to acrylamide from potato crisps to the Spanish population.

    PubMed

    Arribas-Lorenzo, G; Morales, F J

    2009-03-01

    Potato crisps are one of the food commodities that contribute most to overall dietary human exposure of acrylamide. This investigation has estimated the dietary exposure to acrylamide form potato crisps in the Spanish population. Sampling of potato crisps (n = 36) from 16 different producers were carried out in March 2008. An average level of 740 microg kg(-1) (ranging from 81 to 2622 microg kg(-1); minimum to maximum) and a median of 592 microg kg(-1) were obtained. Acrylamide levels in marketed potato crisps have been significantly reduced (nearly to 50%) compared with a previous sampling performed 4 years earlier. The observed signal value (90th percentile) was 1377 microg kg(-1) with 86% of the samples with acrylamide levels lower than 1000 microg kg(-1). Dietary exposure to acrylamide from potato crisp consumption in the total Spanish population was estimated to be 0.042 microg kg(-1) body weight day(-1) by using a deterministic approach based on the National consumption database. In a second study, dietary exposure (based on a 3-day food record) was determined to be 0.053 microg kg(-1) body weight day(-1) for the adult population (17-60 years) and 0.142 microg kg(-1) body weight day(-1) for children (7-12 years). The contribution of potato crisps to the estimated dietary acrylamide exposure of the Spanish population is moderate as compared with other European Member States.

  13. Estimating the center of mass of a free-floating body in microgravity.

    PubMed

    Lejeune, L; Casellato, C; Pattyn, N; Neyt, X; Migeotte, P-F

    2013-01-01

    This paper addresses the issue of estimating the position of the center of mass (CoM) of a free-floating object of unknown mass distribution in microgravity using a stereoscopic imaging system. The method presented here is applied to an object of known mass distribution for validation purposes. In the context of a study of 3-dimensional ballistocardiography in microgravity, and the elaboration of a physical model of the cardiovascular adaptation to weightlessness, the hypothesis that the fluid shift towards the head of astronauts induces a significant shift of their CoM needs to be tested. The experiments were conducted during the 57th parabolic flight campaign of the European Space Agency (ESA). At the beginning of the microgravity phase, the object was given an initial translational and rotational velocity. A 3D point cloud corresponding to the object was then generated, to which a motion-based method inspired by rigid body physics was applied. Through simulations, the effects of the centroid-to-CoM distance and the number of frames of the sequence are investigated. In experimental conditions, considering the important residual accelerations of the airplane during the microgravity phases, CoM estimation errors (16 to 76 mm) were consistent with simulations. Overall, our results suggest that the method has a good potential for its later generalization to a free-floating human body in a weightless environment.

  14. Body Density Estimates from Upper-Body Skinfold Thicknesses Compared to Air-Displacement Plethysmography

    USDA-ARS?s Scientific Manuscript database

    Technical Summary Objectives: Determine the effect of body mass index (BMI) on the accuracy of body density (Db) estimated with skinfold thickness (SFT) measurements compared to air displacement plethysmography (ADP) in adults. Subjects/Methods: We estimated Db with SFT and ADP in 131 healthy men an...

  15. [The importance of handprint morphometry for determining the human body length].

    PubMed

    Grigor'eva, M A

    2018-01-01

    Handprint morphometry for the purpose of personality identification still remains a relatively novel approach. The methods employed for the measurements are not infrequently difficult to reproduce and therefore cause controversy. The objective of the present study was to introduce the system of methods for the measurement of handprints suitable for the reliable determination of the human body length. The study included the measurement of the size of 40 handprints left by124 adult subjects (52 men and 72 women). Two methods of the regression analysis, stepwise and forced inclusion, were applied to the combined group of handprints to select the equations with the high (R>0.800) coefficients of multiple correlation with the body length. 13 equations of multiple regression were obtained and analyzed. The standard error of estimating (SEE) varied from 4.30 to 5.19 cm. The best results were obtained with the equations constructed from the sizes I, II, and III of the rays without their distal phalanges. It was shown that the body length can be successfully reconstructed within the height range from 168 to 183 cm for men and from 157 to 176 cm for women. The examples of the use of the equations for the purpose of expertise of illegible and incomplete handprints are presented.

  16. Exploring the relationship between α-actinin-3 deficiency and obesity in mice and humans.

    PubMed

    Houweling, P J; Berman, Y D; Turner, N; Quinlan, K G R; Seto, J T; Yang, N; Lek, M; Macarthur, D G; Cooney, G; North, K N

    2017-07-01

    Obesity is a worldwide health crisis, and the identification of genetic modifiers of weight gain is crucial in understanding this complex disorder. A common null polymorphism in the fast fiber-specific gene ACTN3 (R577X) is known to influence skeletal muscle function and metabolism. α-Actinin-3 deficiency occurs in an estimated 1.5 billion people worldwide, and results in reduced muscle strength and a shift towards a more efficient oxidative metabolism. The X-allele has undergone strong positive selection during recent human evolution, and in this study, we sought to determine whether ACTN3 genotype influences weight gain and obesity in mice and humans. An Actn3 KO mouse has been generated on two genetic backgrounds (129X1/SvJ and C57BL/6J) and fed a high-fat diet (HFD, 45% calories from fat). Anthropomorphic features (including body weight) were examined and show that Actn3 KO 129X1/SvJ mice gained less weight compared to WT. In addition, six independent human cohorts were genotyped for ACTN3 R577X (Rs1815739) and body mass index (BMI), waist-to-hip ratio-adjusted BMI (WHRadjBMI) and obesity-related traits were assessed. In humans, ACTN3 genotype alone does not contribute to alterations in BMI or obesity.

  17. Dosimetry for radiobiological studies of the human hematopoietic system

    NASA Technical Reports Server (NTRS)

    Beck, W. L.; Stokes, T. R.; Lushbaugh, C. C.

    1972-01-01

    A system for estimating individual bone marrow doses in therapeutic radiation exposures of leukemia patients was studied. These measurements are used to make dose response correlations and to study the effect of dose protraction on peripheral blood cell levels. Three irradiators designed to produce a uniform field of high energy gamma radiation for total body exposures of large animals and man are also used for radiobiological studies.

  18. Evaluation of Allergy Effector Cell Function: Suppression of Basophils in Chronic Helminth Infections

    DTIC Science & Technology

    2011-01-01

    cylindrical bodies, make up the largest group of helminths that parasitize humans. A 1997 World Health Organization study estimated that nearly 4 billion... eosinophilia in the lung was markedly reduced, compared to uninfected sensitized controls. Some of the protection in this model was associated with...the prevention of airway eosinophilia and reduced airway hyperreactivity after OVA challenge (38). When excretory/secretory products obtained from

  19. Estimating Impacts of Treatment Random Assignment on Classroom Quality in the Head Start Impact Study: The Problem of Missing Data

    ERIC Educational Resources Information Center

    Friedman-Krauss, Allison H.; Connors, Maia C.; Morris, Pamela A.

    2013-01-01

    As a result of the 1998 reauthorization of Head Start, the Department of Health and Human Services conducted a national evaluation of the Head Start program. The goal of Head Start is to improve the school readiness skills of low-income children in the United States. There is a substantial body of experimental and correlational research that has…

  20. Gender and Ethnicity Classification from Small Subsets of Human Body Measurements

    DTIC Science & Technology

    2014-03-01

    SIGNATURE PAGE Using Government drawings, specifications, or other data included in this document for any purpose other than Government procurement...does not in any way obligate the U.S. Government. The fact that the Government formulated or supplied the drawings, specifications, or other data does...collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources

  1. The prediction of speed and incline in outdoor running in humans using accelerometry.

    PubMed

    Herren, R; Sparti, A; Aminian, K; Schutz, Y

    1999-07-01

    To explore whether triaxial accelerometric measurements can be utilized to accurately assess speed and incline of running in free-living conditions. Body accelerations during running were recorded at the lower back and at the heel by a portable data logger in 20 human subjects, 10 men, and 10 women. After parameterizing body accelerations, two neural networks were designed to recognize each running pattern and calculate speed and incline. Each subject ran 18 times on outdoor roads at various speeds and inclines; 12 runs were used to calibrate the neural networks whereas the 6 other runs were used to validate the model. A small difference between the estimated and the actual values was observed: the square root of the mean square error (RMSE) was 0.12 m x s(-1) for speed and 0.014 radiant (rad) (or 1.4% in absolute value) for incline. Multiple regression analysis allowed accurate prediction of speed (RMSE = 0.14 m x s(-1)) but not of incline (RMSE = 0.026 rad or 2.6% slope). Triaxial accelerometric measurements allows an accurate estimation of speed of running and incline of terrain (the latter with more uncertainty). This will permit the validation of the energetic results generated on the treadmill as applied to more physiological unconstrained running conditions.

  2. Human-Robot Control Strategies for the NASA/DARPA Robonaut

    NASA Technical Reports Server (NTRS)

    Diftler, M. A.; Culbert, Chris J.; Ambrose, Robert O.; Huber, E.; Bluethmann, W. J.

    2003-01-01

    The Robotic Systems Technology Branch at the NASA Johnson Space Center (JSC) is currently developing robot systems to reduce the Extra-Vehicular Activity (EVA) and planetary exploration burden on astronauts. One such system, Robonaut, is capable of interfacing with external Space Station systems that currently have only human interfaces. Robonaut is human scale, anthropomorphic, and designed to approach the dexterity of a space-suited astronaut. Robonaut can perform numerous human rated tasks, including actuating tether hooks, manipulating flexible materials, soldering wires, grasping handrails to move along space station mockups, and mating connectors. More recently, developments in autonomous control and perception for Robonaut have enabled dexterous, real-time man-machine interaction. Robonaut is now capable of acting as a practical autonomous assistant to the human, providing and accepting tools by reacting to body language. A versatile, vision-based algorithm for matching range silhouettes is used for monitoring human activity as well as estimating tool pose.

  3. Human Skin Is the Largest Epithelial Surface for Interaction with Microbes.

    PubMed

    Gallo, Richard L

    2017-06-01

    Human skin contains an abundant and diverse population of microbial organisms. Many of these microbes inhabit follicular structures of the skin. Furthermore, numerous studies have shown that the interaction of some members of the skin microbiome with host cells will result in changes in cell function. However, estimates of the potential for the microbiome to influence human health through skin have ignored the inner follicular surface, and therefore vastly underestimated the potential of the skin microbiome to have a systemic effect on the human body. By calculating the surface area of follicular and the interfollicular epithelial surface it is shown that skin provides a vast interface for interactions with the microbiome. Copyright © 2017 The Author. Published by Elsevier Inc. All rights reserved.

  4. Influence of Caloric Vestibular Stimulation on Body Experience in Healthy Humans

    PubMed Central

    Schönherr, Andreas; May, Christian Albrecht

    2016-01-01

    The vestibular system has more connections with and influence on higher cortical centers than previously thought. These interactions with higher cortical centers and the phenomena that they elicit require a structural intact cerebral cortex. To date, little is known about the role and influence of the vestibular system on one’s body experience. In this study we show that caloric vestibular stimulation (CVS) in healthy participants has an effect on the perceptive component of one’s body experience. After CVS all participants showed a statistically significant difference of thigh width estimation. In contrast to previous studies, which demonstrated an influence of CVS on higher cortical centers with an intact cerebral cortex both the cognitive and affective component of body experience were not effected by the CVS. Our results demonstrate the influence of the vestibular system on body perception and emphasize its role in modulating different perceptive-qualities which contributes to our body experience. We found that CVS has a limited influence on one’s conscious state, thought process and higher cortical functions. PMID:27013995

  5. [Contents of vitreous humor of dead body with different postmortem intervals].

    PubMed

    Tao, Tao; Xu, Jing; Luo, Tong-Xing; Liao, Zhi-Gang; Pan, Hong-Fu

    2006-11-01

    To establish regression correlations between postmortem interval (PMI) and contents of human vitreous humor of dead bodies for forensic purposes. The human vitreous humor were taken from 126 dead bodies between 0.5 to 216 hours after death, and 11 chemical elements were detected by the OLYMPUS AU400 auto-biochemistry instrument. (1) The glucose, natrium and chlorine in human vitreous humor decreased, while the urea, creatinine, uric acid, potassium, calcium, magnesium, phosphorus, and micro-protein increased after death. The change of glucose, potassium and phosphorus were well correlated with the PMI (r = 0.824, 0.967, 0.880). But the uric acid and micro-protein did not have a good correlation with the PMI(r = 0.350, 0.153). (2) The stepwise regression analysis established the following equations for the PMI (Y): Y = -35. 15+6.05X, R2 = 0.957 (X = potassium); Y = -27.83+ 5.49X(1) - 1.35X(2), R2 = 0.960 (X(1) = potassium, X(2) = glucose); Y = -6.37+3.93X(1) -2.29X(2) + 5.36X(3), R2 = 0.966 (X(1) = potassium, X(2) = glucose, X(3) = phosphorus). (1) Eleven chemical components in human vitreous humor change after death, among which postassium has the best linear correlation with the PMI within 72 hours after death. (2) The accuracy of the estimation of PMI could be improved by establishing a multi-variable equation through stepwise regression.

  6. A biokinetic model for systemic technetium in adult humans

    DOE PAGES

    Leggett, Richard Wayne; Giussani, Augusto

    2015-04-10

    The International Commission on Radiological Protection (ICRP) currently is updating its biokinetic and dosimetric models for internally deposited radionuclides. Technetium (Tc), the lightest element that exists only in radioactive form, has two important isotopes from the standpoint of potential risk to humans: the long-lived isotope 99Tm(T 1/2=2.1x10 5 y) is present in high concentration in nuclear waste, and the short-lived isotope 99mTc (T 1/2=6.02 h) is the most commonly used radionuclide in diagnostic nuclear medicine. This paper reviews data on the biological behavior of technetium and proposes a biokinetic model for systemic technetium in the adult human body formore » use in radiation protection. Compared with the ICRP s current occupational model for systemic technetium, the proposed model provides a more realistic description of the paths of movement of technetium in the body; provides greater consistency with experimental and medical data; and, for most radiosensitive organs, yields substantially different estimates of cumulative activity (total radioactive decays within the organ) following uptake of 99Tm or 99mTc to blood.« less

  7. Ecosystem services impacts associated with environmental ...

    EPA Pesticide Factsheets

    Nitrogen release to the environment from human activities can have important and costly impacts on human health, recreation, transportation, fisheries, and ecosystem health. Recent efforts to quantify these damage costs have identified annual damages associated with reactive nitrogen release to the EU and US in the hundreds of billions of US dollars (USD). The general approach used to estimate these damages associated with reactive nitrogen are derived from a variety of methods to estimate economic damages, for example, impacts to human respiratory health in terms of hospital visits and mortality, willingness to pay to improve a water body and costs to replace or treat drinking water systems affected by nitrate or cyanotoxin contamination. These values are then extrapolated to other areas to develop the damage cost estimates that are probably best seen as potential damage costs, particularly for aquatic ecosystems. We seek to provide an additional verification of these potential damages using data assembled by the US EPA for case studies of measured costs of nutrient impacts across the US from 2000-2012. We compare the spatial distribution and the magnitude of these costs with the spatial distribution and magnitude of costs from HUC8 watershed units across the US by Sobota et al. (2015). We anticipate that this analysis will provide a ground truthing of existing damage cost estimates, and continue to support the incorporation of cost and benefit informatio

  8. Daily thanatomicrobiome changes in soil as an approach of postmortem interval estimation: An ecological perspective.

    PubMed

    Adserias-Garriga, Joe; Hernández, Marta; Quijada, Narciso M; Rodríguez Lázaro, David; Steadman, Dawnie; Garcia-Gil, Jesús

    2017-09-01

    Understanding human decomposition is critical for its use in postmortem interval (PMI) estimation, having a significant impact on forensic investigations. In recognition of the need to establish the scientific basis for PMI estimation, several studies on decomposition have been carried out in the last years. The aims of the present study were: (i) to identify soil microbiota communities involved in human decomposition through high-throughput sequencing (HTS) of DNA sequences from the different bacteria, (ii) to monitor quantitatively and qualitatively the decay of such signature species, and (iii) to describe succesional changes in bacterial populations from the early putrefaction state until skeletonization. Three donated individuals to the University of Tennessee FAC were studied. Soil samples around the body were taken from the placement of the donor until advanced decay/dry remains stage. Bacterial DNA extracts were obtained from the samples, HTS techniques were applied and bioinformatic data analysis was performed. The three cadavers showed similar overall successional changes. At the beginning of the decomposition process the soil microbiome consisted of diverse indigenous soil bacterial communities. As decomposition advanced, Firmicutes community abundance increased in the soil during the bloat stage. The growth curve of Firmicutes from human remains can be used to estimate time since death during Tennessee summer conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A Virtual Reality Full Body Illusion Improves Body Image Disturbance in Anorexia Nervosa.

    PubMed

    Keizer, Anouk; van Elburg, Annemarie; Helms, Rossa; Dijkerman, H Chris

    2016-01-01

    Patients with anorexia nervosa (AN) have a persistent distorted experience of the size of their body. Previously we found that the Rubber Hand Illusion improves hand size estimation in this group. Here we investigated whether a Full Body Illusion (FBI) affects body size estimation of body parts more emotionally salient than the hand. In the FBI, analogue to the RHI, participants experience ownership over an entire virtual body in VR after synchronous visuo-tactile stimulation of the actual and virtual body. We asked participants to estimate their body size (shoulders, abdomen, hips) before the FBI was induced, directly after induction and at ~2 hour 45 minutes follow-up. The results showed that AN patients (N = 30) decrease the overestimation of their shoulders, abdomen and hips directly after the FBI was induced. This effect was strongest for estimates of circumference, and also observed in the asynchronous control condition of the illusion. Moreover, at follow-up, the improvements in body size estimation could still be observed in the AN group. Notably, the HC group (N = 29) also showed changes in body size estimation after the FBI, but the effect showed a different pattern than that of the AN group. The results lead us to conclude that the disturbed experience of body size in AN is flexible and can be changed, even for highly emotional body parts. As such this study offers novel starting points from which new interventions for body image disturbance in AN can be developed.

  10. Kinematic Model-Based Pedestrian Dead Reckoning for Heading Correction and Lower Body Motion Tracking.

    PubMed

    Lee, Min Su; Ju, Hojin; Song, Jin Woo; Park, Chan Gook

    2015-11-06

    In this paper, we present a method for finding the enhanced heading and position of pedestrians by fusing the Zero velocity UPdaTe (ZUPT)-based pedestrian dead reckoning (PDR) and the kinematic constraints of the lower human body. ZUPT is a well known algorithm for PDR, and provides a sufficiently accurate position solution for short term periods, but it cannot guarantee a stable and reliable heading because it suffers from magnetic disturbance in determining heading angles, which degrades the overall position accuracy as time passes. The basic idea of the proposed algorithm is integrating the left and right foot positions obtained by ZUPTs with the heading and position information from an IMU mounted on the waist. To integrate this information, a kinematic model of the lower human body, which is calculated by using orientation sensors mounted on both thighs and calves, is adopted. We note that the position of the left and right feet cannot be apart because of the kinematic constraints of the body, so the kinematic model generates new measurements for the waist position. The Extended Kalman Filter (EKF) on the waist data that estimates and corrects error states uses these measurements and magnetic heading measurements, which enhances the heading accuracy. The updated position information is fed into the foot mounted sensors, and reupdate processes are performed to correct the position error of each foot. The proposed update-reupdate technique consequently ensures improved observability of error states and position accuracy. Moreover, the proposed method provides all the information about the lower human body, so that it can be applied more effectively to motion tracking. The effectiveness of the proposed algorithm is verified via experimental results, which show that a 1.25% Return Position Error (RPE) with respect to walking distance is achieved.

  11. On Inertial Body Tracking in the Presence of Model Calibration Errors

    PubMed Central

    Miezal, Markus; Taetz, Bertram; Bleser, Gabriele

    2016-01-01

    In inertial body tracking, the human body is commonly represented as a biomechanical model consisting of rigid segments with known lengths and connecting joints. The model state is then estimated via sensor fusion methods based on data from attached inertial measurement units (IMUs). This requires the relative poses of the IMUs w.r.t. the segments—the IMU-to-segment calibrations, subsequently called I2S calibrations—to be known. Since calibration methods based on static poses, movements and manual measurements are still the most widely used, potentially large human-induced calibration errors have to be expected. This work compares three newly developed/adapted extended Kalman filter (EKF) and optimization-based sensor fusion methods with an existing EKF-based method w.r.t. their segment orientation estimation accuracy in the presence of model calibration errors with and without using magnetometer information. While the existing EKF-based method uses a segment-centered kinematic chain biomechanical model and a constant angular acceleration motion model, the newly developed/adapted methods are all based on a free segments model, where each segment is represented with six degrees of freedom in the global frame. Moreover, these methods differ in the assumed motion model (constant angular acceleration, constant angular velocity, inertial data as control input), the state representation (segment-centered, IMU-centered) and the estimation method (EKF, sliding window optimization). In addition to the free segments representation, the optimization-based method also represents each IMU with six degrees of freedom in the global frame. In the evaluation on simulated and real data from a three segment model (an arm), the optimization-based method showed the smallest mean errors, standard deviations and maximum errors throughout all tests. It also showed the lowest dependency on magnetometer information and motion agility. Moreover, it was insensitive w.r.t. I2S position and segment length errors in the tested ranges. Errors in the I2S orientations were, however, linearly propagated into the estimated segment orientations. In the absence of magnetic disturbances, severe model calibration errors and fast motion changes, the newly developed IMU centered EKF-based method yielded comparable results with lower computational complexity. PMID:27455266

  12. Comparison of estimated human dose of (68)Ga-MAA with (99m)Tc-MAA based on rat data.

    PubMed

    Shanehsazzadeh, Saeed; Lahooti, Afsaneh; Yousefnia, Hassan; Geramifar, Parham; Jalilian, Amir Reza

    2015-10-01

    (99m)Tc macroaggregated albumin ((99m)Tc-MAA) that had been used as a perfusion agent has been evaluated. In this study, we tried to estimate human absorbed dose of ⁶⁸Ga-MAA via commercially available kit from Pars-Isotopes, based on biodistribution data in wild-type rats, and compare our estimation with the available absorbed dose data from (99m)Tc-MAA. For biodistribution of ⁶⁸Ga-MAA, three rats were sacrificed at each selected times after injection (15, 30, 45, 60, and 120 min) and the percentage of injected dose per gram of each organ was measured by direct counting from rats data from 11 harvested organs. The medical internal radiation dose formulation was applied to extrapolate from rats to human and to project the absorbed radiation dose for various organs in humans. The biodistribution data for ⁶⁸Ga-MAA showed that the most of the activity was taken up by the lung (more than 97 %) in no time. Our dose prediction shows that a 185-MBq injection of ⁶⁸Ga-MAA into humans might result in an estimated absorbed dose of 4.31 mGy in the whole body. The highest absorbed doses are observed in the adrenals, spleen, pancreas, and red marrow with 0.36, 0.34, 0.26, and 0.19 mGy, respectively. Since the (99m)Tc-MAA remains longer than ⁶⁸Ga-MAA in the lung and ⁶⁸Ga-MAA has good image qualities and results in lower amounts of dose delivery to the critical organs such as gonads, red marrow, and adrenals, the use of ⁶⁸Ga-MAA is recommended.

  13. A study on a robot chasing a human using Kinect while identifying walking parameters using the back view

    NASA Astrophysics Data System (ADS)

    Konno, S.; Mita, A.

    2014-03-01

    Recently, the demand of the building spaces to respond to increase of single aged households and the diversification of life style is increasing. Smart house is one of them, but it is difficult for them to be changed and renovated. Therefore, we suggest Biofied builing. In biofied building, we use a mobile robot to get concious and unconcious information about residents and try to make it more secure and comfort builing spaces by realizing the intraction between residents and builing spaces. Walking parameters are one of the most important unconscious information about residents. They are an indicator of autonomy of elderly, and changes of stride length and walking speed may be pridictive of a future fall and a cognitive impairment. By observing their walking and informing residents their walking state, they can forestall such dangers and it helps them to live more securely and autonomously. Many methods to estimate walking parameters have been studied. The famous ones are to use accelerometers and a motion capture camera. Walking parameters estimated by them are high precise but the sensors are attached to a human body in these method and it can make human's walk different from the original walk. Furthermore, some elderly feel it to invade them. In this work, Kinect which can get information about human untouchably was used on the mobile robot. A stride time, stride length, and walking speed were estimated from the back view of human by following him or her. Evaluation was done for 10m, 5m, 4m, and 3m in whole walking. As a result, the proposal system can estimate walking parameters of the walk more than 3m.

  14. Human body region enhancement method based on Kinect infrared imaging

    NASA Astrophysics Data System (ADS)

    Yang, Lei; Fan, Yubo; Song, Xiaowei; Cai, Wenjing

    2016-10-01

    To effectively improve the low contrast of human body region in the infrared images, a combing method of several enhancement methods is utilized to enhance the human body region. Firstly, for the infrared images acquired by Kinect, in order to improve the overall contrast of the infrared images, an Optimal Contrast-Tone Mapping (OCTM) method with multi-iterations is applied to balance the contrast of low-luminosity infrared images. Secondly, to enhance the human body region better, a Level Set algorithm is employed to improve the contour edges of human body region. Finally, to further improve the human body region in infrared images, Laplacian Pyramid decomposition is adopted to enhance the contour-improved human body region. Meanwhile, the background area without human body region is processed by bilateral filtering to improve the overall effect. With theoretical analysis and experimental verification, the results show that the proposed method could effectively enhance the human body region of such infrared images.

  15. Age estimation by using dental radiographs

    PubMed Central

    Limdiwala, Piyush G.; Shah, J. S.

    2013-01-01

    Background: Estimation of age is important in forensic sciences as a way to establish the identity of human remains. Of the various parts of the body used in age estimation, teeth are the least affected by the taphonomic process. Their durability means that they are sometimes the only body part available for study. Several methods of age estimation have been studied using bone and teeth, and among them, tooth wear and apposition of secondary dentine are the currently available non-destructive methods. Objectives: The purpose of the study was to determine the age of adults by using Kvaal's method as well as to establish the relationship of chronological age and dental age with its reliability and limitations on digital panoramic radiographs. Materials and Methods: The present study was based on panoramic radiographs that consisted of two groups. One hundred orthopantomographs with Kvaal's criteria (Group A) and 50 orthopantomographs without Kvaal's criteria (Group B) were included. Various parameters were measured and the result was analyzed by means of SPSS-12.0 program statistical data. Result and Conclusion: On the basis of Kvaal's criteria, the difference between chronological age and real age was 8.3 years. This suggests that the accuracy of this method depends on the precision of measurements and quality and number of the orthopantomographs. PMID:24255560

  16. "Life history space": a multivariate analysis of life history variation in extant and extinct Malagasy lemurs.

    PubMed

    Catlett, Kierstin K; Schwartz, Gary T; Godfrey, Laurie R; Jungers, William L

    2010-07-01

    Studies of primate life history variation are constrained by the fact that all large-bodied extant primates are haplorhines. However, large-bodied strepsirrhines recently existed. If we can extract life history information from their skeletons, these species can contribute to our understanding of primate life history variation. This is particularly important in light of new critiques of the classic "fast-slow continuum" as a descriptor of variation in life history profiles across mammals in general. We use established dental histological methods to estimate gestation length and age at weaning for five extinct lemur species. On the basis of these estimates, we reconstruct minimum interbirth intervals and maximum reproductive rates. We utilize principal components analysis to create a multivariate "life history space" that captures the relationships among reproductive parameters and brain and body size in extinct and extant lemurs. Our data show that, whereas large-bodied extinct lemurs can be described as "slow" in some fashion, they also varied greatly in their life history profiles. Those with relatively large brains also weaned their offspring late and had long interbirth intervals. These were not the largest of extinct lemurs. Thus, we distinguish size-related life history variation from variation that linked more strongly to ecological factors. Because all lemur species larger than 10 kg, regardless of life history profile, succumbed to extinction after humans arrived in Madagascar, we argue that large body size increased the probability of extinction independently of reproductive rate. We also provide some evidence that, among lemurs, brain size predicts reproductive rate better than body size. (c) 2010 Wiley-Liss, Inc.

  17. Non-invasive heart rate monitoring system using giant magneto resistance sensor.

    PubMed

    Kalyan, Kubera; Chugh, Vinit Kumar; Anoop, C S

    2016-08-01

    A simple heart rate (HR) monitoring system designed and developed using the Giant Magneto-Resistance (GMR) sensor is presented in this paper. The GMR sensor is placed on the wrist of the human and it provides the magneto-plethysmographic signal. This signal is processed by the simple analog and digital instrumentation stages to render the heart rate indication. A prototype of the system has been built and test results on 26 volunteers have been reported. The error in HR estimation of the system is merely 1 beat per minute. The performance of the system when layer of cloth is present between the sensor and the human body is investigated. The capability of the system as a HR variability estimator has also been established through experimentation. The proposed technique can be used as an efficient alternative to conventional HR monitors and is well suited for remote and continuous monitoring of HR.

  18. Precision of EM Simulation Based Wireless Location Estimation in Multi-Sensor Capsule Endoscopy

    PubMed Central

    Ye, Yunxing; Aisha, Ain-Ul; Swar, Pranay; Pahlavan, Kaveh

    2018-01-01

    In this paper, we compute and examine two-way localization limits for an RF endoscopy pill as it passes through an individuals gastrointestinal (GI) tract. We obtain finite-difference time-domain and finite element method-based simulation results position assessment employing time of arrival (TOA). By means of a 3-D human body representation from a full-wave simulation software and lognormal models for TOA propagation from implant organs to body surface, we calculate bounds on location estimators in three digestive organs: stomach, small intestine, and large intestine. We present an investigation of the causes influencing localization precision, consisting of a range of organ properties; peripheral sensor array arrangements, number of pills in cooperation, and the random variations in transmit power of sensor nodes. We also perform a localization precision investigation for the situation where the transmission signal of the antenna is arbitrary with a known probability distribution. The computational solver outcome shows that the number of receiver antennas on the exterior of the body has higher impact on the precision of the location than the amount of capsules in collaboration within the GI region. The large intestine is influenced the most by the transmitter power probability distribution. PMID:29651364

  19. Precision of EM Simulation Based Wireless Location Estimation in Multi-Sensor Capsule Endoscopy.

    PubMed

    Khan, Umair; Ye, Yunxing; Aisha, Ain-Ul; Swar, Pranay; Pahlavan, Kaveh

    2018-01-01

    In this paper, we compute and examine two-way localization limits for an RF endoscopy pill as it passes through an individuals gastrointestinal (GI) tract. We obtain finite-difference time-domain and finite element method-based simulation results position assessment employing time of arrival (TOA). By means of a 3-D human body representation from a full-wave simulation software and lognormal models for TOA propagation from implant organs to body surface, we calculate bounds on location estimators in three digestive organs: stomach, small intestine, and large intestine. We present an investigation of the causes influencing localization precision, consisting of a range of organ properties; peripheral sensor array arrangements, number of pills in cooperation, and the random variations in transmit power of sensor nodes. We also perform a localization precision investigation for the situation where the transmission signal of the antenna is arbitrary with a known probability distribution. The computational solver outcome shows that the number of receiver antennas on the exterior of the body has higher impact on the precision of the location than the amount of capsules in collaboration within the GI region. The large intestine is influenced the most by the transmitter power probability distribution.

  20. Monitoring the water balance of Lake Victoria, East Africa, from space

    NASA Astrophysics Data System (ADS)

    Swenson, Sean; Wahr, John

    2009-05-01

    SummaryUsing satellite gravimetric and altimetric data, we examine trends in water storage and lake levels of multiple lakes in the Great Rift Valley region of East Africa for the years 2003-2008. GRACE total water storage estimates reveal that water storage declined in much of East Africa, by as much as 60 {mm}/{year}, while altimetric data show that lake levels in some large lakes dropped by as much as 1-2 m. The largest declines occurred in Lake Victoria, the Earth's second largest freshwater body. Because the discharge from the outlet of Lake Victoria is used to generate hydroelectric power, the role of human management in the lake's decline has been questioned. By comparing catchment water storage trends to lake level trends, we confirm that climatic forcing explains only about 50decline. This analysis provides an independent means of assessing the relative impacts of climate and human management on the water balance of Lake Victoria that does not depend on observations of dam discharge, which may not be publically available. In the second part of the study, the individual components of the lake water balance are estimated. Satellite estimates of changes in lake level, precipitation, and evaporation are used with observed lake discharge to develop a parameterization for estimating subsurface inflows due to changes in groundwater storage estimated from satellite gravimetry. At seasonal timescales, this approach provides closure to Lake Victoria's water balance to within 17 {mm}/{month}. The third part of this study uses the water balance of a downstream water body, Lake Kyoga, to estimate the outflow from Lake Victoria remotely. Because Lake Kyoga is roughly 20 times smaller in area than Lake Victoria, its water balance is strongly influenced by inflow from Lake Victoria. Lake Kyoga has been shown to act as a linear reservoir, where its outflow is proportional to the height of the lake. This model can be used with satellite altimetric lake levels to estimate a time series of Lake Victoria discharge with an rms error of about 134 {m}/{s}.

  1. Linearized motion estimation for articulated planes.

    PubMed

    Datta, Ankur; Sheikh, Yaser; Kanade, Takeo

    2011-04-01

    In this paper, we describe the explicit application of articulation constraints for estimating the motion of a system of articulated planes. We relate articulations to the relative homography between planes and show that these articulations translate into linearized equality constraints on a linear least-squares system, which can be solved efficiently using a Karush-Kuhn-Tucker system. The articulation constraints can be applied for both gradient-based and feature-based motion estimation algorithms and to illustrate this, we describe a gradient-based motion estimation algorithm for an affine camera and a feature-based motion estimation algorithm for a projective camera that explicitly enforces articulation constraints. We show that explicit application of articulation constraints leads to numerically stable estimates of motion. The simultaneous computation of motion estimates for all of the articulated planes in a scene allows us to handle scene areas where there is limited texture information and areas that leave the field of view. Our results demonstrate the wide applicability of the algorithm in a variety of challenging real-world cases such as human body tracking, motion estimation of rigid, piecewise planar scenes, and motion estimation of triangulated meshes.

  2. Inference of ecological and social drivers of human brain-size evolution.

    PubMed

    González-Forero, Mauricio; Gardner, Andy

    2018-05-01

    The human brain is unusually large. It has tripled in size from Australopithecines to modern humans 1 and has become almost six times larger than expected for a placental mammal of human size 2 . Brains incur high metabolic costs 3 and accordingly a long-standing question is why the large human brain has evolved 4 . The leading hypotheses propose benefits of improved cognition for overcoming ecological 5-7 , social 8-10 or cultural 11-14 challenges. However, these hypotheses are typically assessed using correlative analyses, and establishing causes for brain-size evolution remains difficult 15,16 . Here we introduce a metabolic approach that enables causal assessment of social hypotheses for brain-size evolution. Our approach yields quantitative predictions for brain and body size from formalized social hypotheses given empirical estimates of the metabolic costs of the brain. Our model predicts the evolution of adult Homo sapiens-sized brains and bodies when individuals face a combination of 60% ecological, 30% cooperative and 10% between-group competitive challenges, and suggests that between-individual competition has been unimportant for driving human brain-size evolution. Moreover, our model indicates that brain expansion in Homo was driven by ecological rather than social challenges, and was perhaps strongly promoted by culture. Our metabolic approach thus enables causal assessments that refine, refute and unify hypotheses of brain-size evolution.

  3. Quantification of interstitial fluid on whole body CT: comparison with whole body autopsy.

    PubMed

    Lo Gullo, Roberto; Mishra, Shelly; Lira, Diego A; Padole, Atul; Otrakji, Alexi; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Singh, Sarabjeet; Shepard, Jo-Anne O; Digumarthy, Subba R; Kalra, Mannudeep K; Stone, James R

    2015-12-01

    Interstitial fluid accumulation can occur in pleural, pericardial, and peritoneal spaces, and subcutaneous tissue planes. The purpose of the study was to assess if whole body CT examination in a postmortem setting could help determine the presence and severity of third space fluid accumulation in the body. Our study included 41 human cadavers (mean age 61 years, 25 males and 16 females) who had whole-body postmortem CT prior to autopsy. All bodies were maintained in the morgue in the time interval between death and autopsy. Two radiologists reviewed the whole-body CT examinations independently to grade third space fluid in the pleura, pericardium, peritoneum, and subcutaneous space using a 5-point grading system. Qualitative CT grading for third space fluid was correlated with the amount of fluid found on autopsy and the quantitative CT fluid volume, estimated using a dedicated software program (Volume, Syngo Explorer, Siemens Healthcare). Moderate and severe peripheral edema was seen in 16/41 and 7/41 cadavers respectively. It is not possible to quantify anasarca at autopsy. Correlation between imaging data for third space fluid and the quantity of fluid found during autopsy was 0.83 for pleural effusion, 0.4 for pericardial effusion and 0.9 for ascites. The degree of anasarca was significantly correlated with the severity of ascites (p < 0.0001) but not with pleural or pericardial effusion. There was strong correlation between volumetric estimation and qualitative grading for anasarca (p < 0.0001) and pleural effusion (p < 0.0001). Postmortem CT can help in accurate detection and quantification of third space fluid accumulation. The quantity of ascitic fluid on postmortem CT can predict the extent of anasarca.

  4. Predictive equations for the estimation of body size in seals and sea lions (Carnivora: Pinnipedia)

    PubMed Central

    Churchill, Morgan; Clementz, Mark T; Kohno, Naoki

    2014-01-01

    Body size plays an important role in pinniped ecology and life history. However, body size data is often absent for historical, archaeological, and fossil specimens. To estimate the body size of pinnipeds (seals, sea lions, and walruses) for today and the past, we used 14 commonly preserved cranial measurements to develop sets of single variable and multivariate predictive equations for pinniped body mass and total length. Principal components analysis (PCA) was used to test whether separate family specific regressions were more appropriate than single predictive equations for Pinnipedia. The influence of phylogeny was tested with phylogenetic independent contrasts (PIC). The accuracy of these regressions was then assessed using a combination of coefficient of determination, percent prediction error, and standard error of estimation. Three different methods of multivariate analysis were examined: bidirectional stepwise model selection using Akaike information criteria; all-subsets model selection using Bayesian information criteria (BIC); and partial least squares regression. The PCA showed clear discrimination between Otariidae (fur seals and sea lions) and Phocidae (earless seals) for the 14 measurements, indicating the need for family-specific regression equations. The PIC analysis found that phylogeny had a minor influence on relationship between morphological variables and body size. The regressions for total length were more accurate than those for body mass, and equations specific to Otariidae were more accurate than those for Phocidae. Of the three multivariate methods, the all-subsets approach required the fewest number of variables to estimate body size accurately. We then used the single variable predictive equations and the all-subsets approach to estimate the body size of two recently extinct pinniped taxa, the Caribbean monk seal (Monachus tropicalis) and the Japanese sea lion (Zalophus japonicus). Body size estimates using single variable regressions generally under or over-estimated body size; however, the all-subset regression produced body size estimates that were close to historically recorded body length for these two species. This indicates that the all-subset regression equations developed in this study can estimate body size accurately. PMID:24916814

  5. Anthropometric changes in elite male water polo players: survey in 1980 and 1995.

    PubMed

    Lozovina, Vinko; Pavicić, Leo

    2004-04-01

    To assess the differences in anthropometric parameters, body fat, body mass index (BMI), and body density induced by sport-specific morphological optimization (adaptation) between two generations (1980 and 1995) of male elite water polo players. The survey included a total of 160 elite male water polo players, all members of the top clubs in Croatia. The 1980's generation consisted of 95 players (71.9% of target population) aged between 18 and 32 years, and the 1995's generation included 65 players (50% of target population) aged between 19 and 29 years. Trained and qualified anthropometrists performed the measurements under standardized experimental conditions and in accordance with the procedures described by the International Biological Program. They measured 23 anthropometric variables reflecting basic human body characteristics described by skeletal bone lengths (total leg length, total arm length, hand length, foot length, and height), breadths (hand at proximal phalanges, foot in metatarsal area, biacromial, biiliocristal, biepycondylar femur, biepycondyar humerus, and radio-ulnar wrist breadth), girths (chest, arm, forearm, thigh, and calf girth), skinfold thickness as a measure of subcutaneous adiposity (triceps, subscapular, axillary, calf, and abdominal skinfold thickness), and mass. Additionally, estimates of body mass index (BMI), body density, and percentage of body fat were calculated from the primary measures. Comparison between anthropometric measures of the two generations of water polo players revealed a positive trend in body skeletal measures and negative trend in body adiposity measures. Most noteworthy differences (d) were an increase in height (d=37.3 mm, p

  6. Comparative study of human blood Raman spectra and biochemical analysis of patients with cancer

    NASA Astrophysics Data System (ADS)

    Shamina, Lyudmila A.; Bratchenko, Ivan A.; Artemyev, Dmitry N.; Myakinin, Oleg O.; Moryatov, Alexander A.; Orlov, Andrey E.; Kozlov, Sergey V.; Zakharov, Valery P.

    2018-04-01

    In this study we measured spectral features of blood by Raman spectroscopy. Correlation of the obtained spectral data and biochemical studies results is investigated. Analysis of specific spectra allows for identification of informative spectral bands proportional to components whose content is associated with body fluids homeostasis changes at various pathological conditions. Regression analysis of the obtained spectral data allows for discriminating the lung cancer from other tumors with a posteriori probability of 88.3%. The potentiality of applying surface-enhanced Raman spectroscopy with utilized experimental setup for further studies of the body fluids component composition was estimated. The greatest signal amplification was achieved for the gold substrate with a surface roughness of 1 μm. In general, the developed approach of body fluids analysis provides the basis of a useful and minimally invasive method of pathologies screening.

  7. Body-on-a-chip simulation with gastrointestinal tract and liver tissues suggests that ingested nanoparticles have the potential to cause liver injury.

    PubMed

    Esch, Mandy B; Mahler, Gretchen J; Stokol, Tracy; Shuler, Michael L

    2014-08-21

    The use of nanoparticles in medical applications is highly anticipated, and at the same time little is known about how these nanoparticles affect human tissues. Here we have simulated the oral uptake of 50 nm carboxylated polystyrene nanoparticles with a microscale body-on-a-chip system (also referred to as multi-tissue microphysiological system or micro Cell Culture Analog). Using the 'GI tract-liver-other tissues' system allowed us to observe compounding effects and detect liver tissue injury at lower nanoparticle concentrations than was expected from experiments with single tissues. To construct this system, we combined in vitro models of the human intestinal epithelium, represented by a co-culture of enterocytes (Caco-2) and mucin-producing cells (TH29-MTX), and the liver, represented by HepG2/C3A cells, within one microfluidic device. The device also contained chambers that together represented the liquid portions of all other organs of the human body. Measuring the transport of 50 nm carboxylated polystyrene nanoparticles across the Caco-2/HT29-MTX co-culture, we found that this multi-cell layer presents an effective barrier to 90.5 ± 2.9% of the nanoparticles. Further, our simulation suggests that a larger fraction of the 9.5 ± 2.9% nanoparticles that travelled across the Caco-2/HT29-MTX cell layer were not large nanoparticle aggregates, but primarily single nanoparticles and small aggregates. After crossing the GI tract epithelium, nanoparticles that were administered in high doses estimated in terms of possible daily human consumption (240 and 480 × 10(11) nanoparticles mL(-1)) induced the release of aspartate aminotransferase (AST), an intracellular enzyme of the liver that indicates liver cell injury. Our results indicate that body-on-a-chip devices are highly relevant in vitro models for evaluating nanoparticle interactions with human tissues.

  8. Body proportions of Homo habilis reviewed.

    PubMed

    Haeusler, Martin; McHenry, Henry M

    2004-04-01

    The ratio of fore- to hindlimb size plays an important role in our understanding of human evolution. Although Homo habilis was relatively modern craniodentally, its body proportions are commonly believed to have been more apelike than in the earlier Australopithecus afarensis. The evidence for this, however, rests, on two fragmentary skeletons, OH 62 and KNM-ER 3735. The upper limb of the better-preserved OH 62 from Olduvai Gorge is long and slender, but its hindlimb is represented mainly by the proximal portion of a thin femur of uncertain length. The present analysis shows that upper-to-lower limb shaft proportions of both OH 62 and AL 288-1 (A. afarensis) fall in the modern human range of variation, although OH 62 also falls inside that of chimpanzees due to their overlap in small individuals. Despite being more fragmentary, the larger-bodied KNM-ER 3735 lies outside the chimpanzee range and close to the human mean. Because the differences between any of the three individuals are compatible with the range of variation seen in extant hominoid groups, it is not legitimate to infer more primitive upper-to-lower limb shaft proportions for either H. habilis or A. afarensis. Femur length of OH 62 can only be estimated by comparison. Its closest match in size and morphology is with the gracile OH 34 specimen, which therefore provides a better analogue for the reconstruction of OH 62 than the stocky AL 288-1 femur that is traditionally used. OH 34's slender proportions are hardly due to abrasion, but match those of a modern human of that body-size, suggesting that the relative length of OH 62's leg may have been human-like. Brachial proportions, however, remained primitive. Long legs may imply long distance terrestrial travel. Perhaps this adaptation evolved early in the genus Homo, with H. habilis providing an early representative of this important change.

  9. Determination of Percent Body Fat Using 3D Whole Body Laser Scanning: A Preliminary Investigation

    DTIC Science & Technology

    2006-11-01

    S.B., Lohman, T.G., Wang, Z., and Going, S.B., 2005: Human body composition: Human Kinetics : Champaign, IL. Heyward, V.H. and Wagner, D.R...2004: Applied body composition assessment: Human Kinetics : Champaign, IL. Hodgdon, J.A., and Beckett, M.B., 1984a: Prediction of percent body fat...ethnicity. In: Human body Composition., Heymsfield, S.B., Lohman, T.G., Wang, Z., and Going, S.B (eds.). Human Kinetics : Champaign, IL. Marriott

  10. A Virtual Reality Full Body Illusion Improves Body Image Disturbance in Anorexia Nervosa

    PubMed Central

    Keizer, Anouk; van Elburg, Annemarie; Helms, Rossa; Dijkerman, H. Chris

    2016-01-01

    Background Patients with anorexia nervosa (AN) have a persistent distorted experience of the size of their body. Previously we found that the Rubber Hand Illusion improves hand size estimation in this group. Here we investigated whether a Full Body Illusion (FBI) affects body size estimation of body parts more emotionally salient than the hand. In the FBI, analogue to the RHI, participants experience ownership over an entire virtual body in VR after synchronous visuo-tactile stimulation of the actual and virtual body. Methods and Results We asked participants to estimate their body size (shoulders, abdomen, hips) before the FBI was induced, directly after induction and at ~2 hour 45 minutes follow-up. The results showed that AN patients (N = 30) decrease the overestimation of their shoulders, abdomen and hips directly after the FBI was induced. This effect was strongest for estimates of circumference, and also observed in the asynchronous control condition of the illusion. Moreover, at follow-up, the improvements in body size estimation could still be observed in the AN group. Notably, the HC group (N = 29) also showed changes in body size estimation after the FBI, but the effect showed a different pattern than that of the AN group. Conclusion The results lead us to conclude that the disturbed experience of body size in AN is flexible and can be changed, even for highly emotional body parts. As such this study offers novel starting points from which new interventions for body image disturbance in AN can be developed. PMID:27711234

  11. On-farm estimation of energy balance in dairy cows using only frequent body weight measurements and body condition score.

    PubMed

    Thorup, V M; Edwards, D; Friggens, N C

    2012-04-01

    Precise energy balance estimates for individual cows are of great importance to monitor health, reproduction, and feed management. Energy balance is usually calculated as energy input minus output (EB(inout)), requiring measurements of feed intake and energy output sources (milk, maintenance, activity, growth, and pregnancy). Except for milk yield, direct measurements of the other sources are difficult to obtain in practice, and estimates contain considerable error sources, limiting on-farm use. Alternatively, energy balance can be estimated from body reserve changes (EB(body)) using body weight (BW) and body condition score (BCS). Automated weighing systems exist and new technology performing semi-automated body condition scoring has emerged, so frequent automated BW and BCS measurements are feasible. We present a method to derive individual EB(body) estimates from frequently measured BW and BCS and evaluate the performance of the estimated EB(body) against the traditional EB(inout) method. From 76 Danish Holstein and Jersey cows, parity 1 or 2+, on a glycerol-rich or a whole grain-rich total mixed ration, BW was measured automatically at each milking. The BW was corrected for the weight of milk produced and for gutfill. Changes in BW and BCS were used to calculate changes in body protein, body lipid, and EB(body) during the first 150 d in milk. The EB(body) was compared with the traditional EB(inout) by isolating the term within EB(inout) associated with most uncertainty; that is, feed energy content (FEC); FEC=(EB(body)+EMilk+EMaintenance+Eactivity)/dry matter intake, where the energy requirements are for milk produced (EMilk), maintenance (EMaintenance), and activity (EActivity). Estimated FEC agreed well with FEC values derived from tables (the mean estimate was 0.21 MJ of effective energy/kg of dry matter or 2.2% higher than the mean table value). Further, the FEC profile did not suggest systematic bias in EB(body) with stage of lactation. The EB(body) estimated from daily BW, adjusted for milk and meal-related gutfill and combined with frequent BCS, can provide a successful tool. This offers a pragmatic solution to on-farm calculation of energy balance with the perspective of improved precision under commercial conditions. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Superparamagnetic nanoparticle-based viscosity test

    NASA Astrophysics Data System (ADS)

    Wu, Kai; Liu, Jinming; Wang, Yi; Ye, Clark; Feng, Yinglong; Wang, Jian-Ping

    2015-08-01

    Hyperviscosity syndrome is triggered by high blood viscosity in the human body. This syndrome can result in retinopathy, vertigo, coma, and other unanticipated complications. Serum viscosity is one of the important factors affecting whole blood viscosity, which is regarded as an indicator of general health. In this letter, we propose and demonstrate a Brownian relaxation-based mixing frequency method to test human serum viscosity. This method uses excitatory and detection coils and Brownian relaxation-dominated superparamagnetic nanoparticles, which are sensitive to variables of the liquid environment such as viscosity and temperature. We collect the harmonic signals produced by magnetic nanoparticles and estimate the viscosity of unknown solutions by comparison to the calibration curves. An in vitro human serum viscosity test is performed in less than 1.5 min.

  13. Assessment of body perception among Swedish adolescents and young adults.

    PubMed

    Bergström, E; Stenlund, H; Svedjehäll, B

    2000-01-01

    To assess body perception in adolescents and young adults without anorexia nervosa. Using a visual size estimation technique, perceived body size was estimated in four groups of Swedish adolescents and young adults without anorexia nervosa (86 males and 95 females). Perceived body size was estimated at nine different body sites comparing these estimations to real body size. The results show that 95% of males and 96% of females overestimated their body size (mean overestimation: males +22%, females +33%). The overestimations were greatest in females. The greatest overestimations were made of the waist (males +31%, females +46%), buttocks (males +22%, females +42%), and thighs (males +27%, females +41%). The results indicate that overestimation of body size may be a general phenomenon in adolescents and young adults in a country such as Sweden, implying a similar, but less pronounced distortion of body image as in individuals with anorexia nervosa.

  14. Body metaphors--reading the body in contemporary culture.

    PubMed

    Skara, Danica

    2004-01-01

    This paper addresses the linguistic reframing of the human body in contemporary culture. Our aim is to provide a linguistic description of the ways in which the body is represented in modern English language. First, we will try to focus on body metaphors in general. We have collected a sample of 300 words and phrases functioning as body metaphors in modern English language. Reading the symbolism of the body we are witnessing changes in the basic metaphorical structuring of the human body. The results show that new vocabulary binds different fields of knowledge associated with machines and human beings according to a shared textual frame: human as computer and computer as human metaphor. Humans are almost blended with computers and vice versa. This metaphorical use of the human body and its parts reveals not only currents of unconscious though but also the structures of modern society and culture.

  15. Human body segmentation via data-driven graph cut.

    PubMed

    Li, Shifeng; Lu, Huchuan; Shao, Xingqing

    2014-11-01

    Human body segmentation is a challenging and important problem in computer vision. Existing methods usually entail a time-consuming training phase for prior knowledge learning with complex shape matching for body segmentation. In this paper, we propose a data-driven method that integrates top-down body pose information and bottom-up low-level visual cues for segmenting humans in static images within the graph cut framework. The key idea of our approach is first to exploit human kinematics to search for body part candidates via dynamic programming for high-level evidence. Then, by using the body parts classifiers, obtaining bottom-up cues of human body distribution for low-level evidence. All the evidence collected from top-down and bottom-up procedures are integrated in a graph cut framework for human body segmentation. Qualitative and quantitative experiment results demonstrate the merits of the proposed method in segmenting human bodies with arbitrary poses from cluttered backgrounds.

  16. Infants' Responses to Real Humans and Representations of Humans

    ERIC Educational Resources Information Center

    Heron, Michelle; Slaughter, Virginia

    2010-01-01

    Infants' responses to typical and scrambled human body shapes were assessed in relation to the realism of the human body stimuli presented. In four separate experiments, infants were familiarized to typical human bodies and then shown a series of scrambled human bodies on the test. Looking behaviour was assessed in response to a range of different…

  17. A body composition model to estimate mammalian energy stores and metabolic rates from body mass and body length, with application to polar bears.

    PubMed

    Molnár, Péter K; Klanjscek, Tin; Derocher, Andrew E; Obbard, Martyn E; Lewis, Mark A

    2009-08-01

    Many species experience large fluctuations in food availability and depend on energy from fat and protein stores for survival, reproduction and growth. Body condition and, more specifically, energy stores thus constitute key variables in the life history of many species. Several indices exist to quantify body condition but none can provide the amount of stored energy. To estimate energy stores in mammals, we propose a body composition model that differentiates between structure and storage of an animal. We develop and parameterize the model specifically for polar bears (Ursus maritimus Phipps) but all concepts are general and the model could be easily adapted to other mammals. The model provides predictive equations to estimate structural mass, storage mass and storage energy from an appropriately chosen measure of body length and total body mass. The model also provides a means to estimate basal metabolic rates from body length and consecutive measurements of total body mass. Model estimates of body composition, structural mass, storage mass and energy density of 970 polar bears from Hudson Bay were consistent with the life history and physiology of polar bears. Metabolic rate estimates of fasting adult males derived from the body composition model corresponded closely to theoretically expected and experimentally measured metabolic rates. Our method is simple, non-invasive and provides considerably more information on the energetic status of individuals than currently available methods.

  18. Differential barometric-based positioning technique for indoor elevation measurement in IoT medical applications.

    PubMed

    Wang, Hua; Wen, Yingyou; Zhao, Dazhe

    2017-07-20

    Medical applications have begun to benefit from Internet of Things (IoT) technology through the introduction of wearable devices. Several medical applications require accurate patient location as various changes affect pressure parameters inside the body. This study aims to develop a system to measure indoor altitude for IoT medical applications. We propose a differential barometric-based positioning system to estimate the altitude between a reference sensor and a localizing sensor connected to the human body. The differential barometric altimetry model is introduced to estimate indoor elevations and eliminate environmental artifacts. In addition, a Gaussian filter processing is adopted to remove noise from the elevation measurements. The proposed system is then investigated through extensive experiments, using various evaluation criteria. The results indicate that the proposed system yielded good accuracy with reduced implementation complexity and fewer costs. The proposed system is resilient compared to other indoor localization approaches, even when numerous environmental artifacts in indoor environments are present.

  19. 3D kinematic measurement of human movement using low cost fish-eye cameras

    NASA Astrophysics Data System (ADS)

    Islam, Atiqul; Asikuzzaman, Md.; Garratt, Matthew A.; Pickering, Mark R.

    2017-02-01

    3D motion capture is difficult when the capturing is performed in an outdoor environment without controlled surroundings. In this paper, we propose a new approach of using two ordinary cameras arranged in a special stereoscopic configuration and passive markers on a subject's body to reconstruct the motion of the subject. Firstly for each frame of the video, an adaptive thresholding algorithm is applied for extracting the markers on the subject's body. Once the markers are extracted, an algorithm for matching corresponding markers in each frame is applied. Zhang's planar calibration method is used to calibrate the two cameras. As the cameras use the fisheye lens, they cannot be well estimated using a pinhole camera model which makes it difficult to estimate the depth information. In this work, to restore the 3D coordinates we use a unique calibration method for fisheye lenses. The accuracy of the 3D coordinate reconstruction is evaluated by comparing with results from a commercially available Vicon motion capture system.

  20. Assessment of exposure to radio frequency electromagnetic fields from smart utility meters in GB; part II) numerical assessment of induced SAR within the human body.

    PubMed

    Qureshi, Muhammad R A; Alfadhl, Yasir; Chen, Xiaodong; Peyman, Azadeh; Maslanyj, Myron; Mann, Simon

    2018-04-01

    Human body exposure to radiofrequency electromagnetic waves emitted from smart meters was assessed using various exposure configurations. Specific energy absorption rate distributions were determined using three anatomically realistic human models. Each model was assigned with age- and frequency-dependent dielectric properties representing a collection of age groups. Generalized exposure conditions involving standing and sleeping postures were assessed for a home area network operating at 868 and 2,450 MHz. The smart meter antenna was fed with 1 W power input which is an overestimation of what real devices typically emit (15 mW max limit). The highest observed whole body specific energy absorption rate value was 1.87 mW kg -1 , within the child model at a distance of 15 cm from a 2,450 MHz device. The higher values were attributed to differences in dimension and dielectric properties within the model. Specific absorption rate (SAR) values were also estimated based on power density levels derived from electric field strength measurements made at various distances from smart meter devices. All the calculated SAR values were found to be very small in comparison to International Commission on Non-Ionizing Radiation Protection limits for public exposure. Bioelectromagnetics. 39:200-216, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  1. Optimal External Wrench Distribution During a Multi-Contact Sit-to-Stand Task.

    PubMed

    Bonnet, Vincent; Azevedo-Coste, Christine; Robert, Thomas; Fraisse, Philippe; Venture, Gentiane

    2017-07-01

    This paper aims at developing and evaluating a new practical method for the real-time estimate of joint torques and external wrenches during multi-contact sit-to-stand (STS) task using kinematics data only. The proposed method allows also identifying subject specific body inertial segment parameters that are required to perform inverse dynamics. The identification phase is performed using simple and repeatable motions. Thanks to an accurately identified model the estimate of the total external wrench can be used as an input to solve an under-determined multi-contact problem. It is solved using a constrained quadratic optimization process minimizing a hybrid human-like energetic criterion. The weights of this hybrid cost function are adjusted and a sensitivity analysis is performed in order to reproduce robustly human external wrench distribution. The results showed that the proposed method could successfully estimate the external wrenches under buttocks, feet, and hands during STS tasks (RMS error lower than 20 N and 6 N.m). The simplicity and generalization abilities of the proposed method allow paving the way of future diagnosis solutions and rehabilitation applications, including in-home use.

  2. A Method for Calculating the Amount of Movements to Estimate the Self-position of Manta Robots

    NASA Astrophysics Data System (ADS)

    Imahama, Takuya; Watanabe, Keigo; Mikuriya, Kota; Nagai, Isaku

    2018-02-01

    In recent years, the demand of underwater investigation is increasing in the circumference of a dam, the environmental research of the shallow where approach by ship is difficult, etc. It is known, however, that for man, all over the sea, danger exists mostly, and prolonged diving has a bad influence to a human body. Then, the development of underwater exploration robots that investigate underwater instead of humans is expected. Among underwater exploration robots, it is known that robots imitating aquatic organisms have little influence on underwater environment. Therefore, at this laboratory, a Manta robot using propulsive mechanisms with pectoral fins was developed, imitating the pectoral fin of Manta. Although underwater environmental research needs a function for estimating the self-position, it is not mounted in this Manta robot. This paper explains the amount estimation of movements using optical flows. Especially, a gimbal mechanism is introduced to reduce the influence on the optical flow calculation by pitch motion of the Manta robot. Several experiments are conducted to demonstrate the usefulness of the proposed method.

  3. The Human Retrosplenial Cortex and Thalamus Code Head Direction in a Global Reference Frame.

    PubMed

    Shine, Jonathan P; Valdés-Herrera, José P; Hegarty, Mary; Wolbers, Thomas

    2016-06-15

    Spatial navigation is a multisensory process involving integration of visual and body-based cues. In rodents, head direction (HD) cells, which are most abundant in the thalamus, integrate these cues to code facing direction. Human fMRI studies examining HD coding in virtual environments (VE) have reported effects in retrosplenial complex and (pre-)subiculum, but not the thalamus. Furthermore, HD coding appeared insensitive to global landmarks. These tasks, however, provided only visual cues for orientation, and attending to global landmarks did not benefit task performance. In the present study, participants explored a VE comprising four separate locales, surrounded by four global landmarks. To provide body-based cues, participants wore a head-mounted display so that physical rotations changed facing direction in the VE. During subsequent MRI scanning, subjects saw stationary views of the environment and judged whether their orientation was the same as in the preceding trial. Parameter estimates extracted from retrosplenial cortex and the thalamus revealed significantly reduced BOLD responses when HD was repeated. Moreover, consistent with rodent findings, the signal did not continue to adapt over repetitions of the same HD. These results were supported by a whole-brain analysis showing additional repetition suppression in the precuneus. Together, our findings suggest that: (1) consistent with the rodent literature, the human thalamus may integrate visual and body-based, orientation cues; (2) global reference frame cues can be used to integrate HD across separate individual locales; and (3) immersive training procedures providing full body-based cues may help to elucidate the neural mechanisms supporting spatial navigation. In rodents, head direction (HD) cells signal facing direction in the environment via increased firing when the animal assumes a certain orientation. Distinct brain regions, the retrosplenial cortex (RSC) and thalamus, code for visual and vestibular cues of orientation, respectively. Putative HD signals have been observed in human RSC but not the thalamus, potentially because body-based cues were not provided. Here, participants encoded HD in a novel virtual environment while wearing a head-mounted display to provide body-based cues for orientation. In subsequent fMRI scanning, we found evidence of an HD signal in RSC, thalamus, and precuneus. These findings harmonize rodent and human data, and suggest that immersive training procedures provide a viable way to examine the neural basis of navigation. Copyright © 2016 the authors 0270-6474/16/366371-11$15.00/0.

  4. Articular scaling and body mass estimation in platyrrhines and catarrhines: Modern variation and application to fossil anthropoids.

    PubMed

    Perry, Jonathan M G; Cooke, Siobhán B; Runestad Connour, Jacqueline A; Burgess, M Loring; Ruff, Christopher B

    2018-02-01

    Body mass is an important component of any paleobiological reconstruction. Reliable skeletal dimensions for making estimates are desirable but extant primate reference samples with known body masses are rare. We estimated body mass in a sample of extinct platyrrhines and Fayum anthropoids based on four measurements of the articular surfaces of the humerus and femur. Estimates were based on a large extant reference sample of wild-collected individuals with associated body masses, including previously published and new data from extant platyrrhines, cercopithecoids, and hominoids. In general, scaling of joint dimensions is positively allometric relative to expectations of geometric isometry, but negatively allometric relative to expectations of maintaining equivalent joint surface areas. Body mass prediction equations based on articular breadths are reasonably precise, with %SEEs of 17-25%. The breadth of the distal femoral articulation yields the most reliable estimates of body mass because it scales similarly in all major anthropoid taxa. Other joints scale differently in different taxa; therefore, locomotor style and phylogenetic affinity must be considered when calculating body mass estimates from the proximal femur, proximal humerus, and distal humerus. The body mass prediction equations were applied to 36 Old World and New World fossil anthropoid specimens representing 11 taxa, plus two Haitian specimens of uncertain taxonomic affinity. Among the extinct platyrrhines studied, only Cebupithecia is similar to large, extant platyrrhines in having large humeral (especially distal) joints. Our body mass estimates differ from each other and from published estimates based on teeth in ways that reflect known differences in relative sizes of the joints and teeth. We prefer body mass estimators that are biomechanically linked to weight-bearing, and especially those that are relatively insensitive to differences in locomotor style and phylogenetic history. Whenever possible, extant reference samples should be chosen to match target fossils in joint proportionality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Detection and determination of organophosphorus insecticides in tissues by thin-layer chromatography.

    PubMed

    Tewari, S N; Harpalani, S P

    1977-01-11

    The toxicological analysis of 12 common organophosphorus insecticides is described. Suitable methods for the extraction of organophosphorus insecticides from tissues are proposed. The detection, identification and estimation of these insecticides by thin-layer chromatography is described for 25 solvent systems and a series of chromogenic reagents. The distribution of insecticides in human body tissues in five cases of poisoning by ethyl parathion, malathion, dimethoate, sumithion and phosphamidon has also been studied.

  6. Linking neuronal brain activity to the glucose metabolism.

    PubMed

    Göbel, Britta; Oltmanns, Kerstin M; Chung, Matthias

    2013-08-29

    Energy homeostasis ensures the functionality of the entire organism. The human brain as a missing link in the global regulation of the complex whole body energy metabolism is subject to recent investigation. The goal of this study is to gain insight into the influence of neuronal brain activity on cerebral and peripheral energy metabolism. In particular, the tight link between brain energy supply and metabolic responses of the organism is of interest. We aim to identifying regulatory elements of the human brain in the whole body energy homeostasis. First, we introduce a general mathematical model describing the human whole body energy metabolism. It takes into account the two central roles of the brain in terms of energy metabolism. The brain is considered as energy consumer as well as regulatory instance. Secondly, we validate our mathematical model by experimental data. Cerebral high-energy phosphate content and peripheral glucose metabolism are measured in healthy men upon neuronal activation induced by transcranial direct current stimulation versus sham stimulation. By parameter estimation we identify model parameters that provide insight into underlying neurophysiological processes. Identified parameters reveal effects of neuronal activity on regulatory mechanisms of systemic glucose metabolism. Our examinations support the view that the brain increases its glucose supply upon neuronal activation. The results indicate that the brain supplies itself with energy according to its needs, and preeminence of cerebral energy supply is reflected. This mechanism ensures balanced cerebral energy homeostasis. The hypothesis of the central role of the brain in whole body energy homeostasis as active controller is supported.

  7. Linking neuronal brain activity to the glucose metabolism

    PubMed Central

    2013-01-01

    Background Energy homeostasis ensures the functionality of the entire organism. The human brain as a missing link in the global regulation of the complex whole body energy metabolism is subject to recent investigation. The goal of this study is to gain insight into the influence of neuronal brain activity on cerebral and peripheral energy metabolism. In particular, the tight link between brain energy supply and metabolic responses of the organism is of interest. We aim to identifying regulatory elements of the human brain in the whole body energy homeostasis. Methods First, we introduce a general mathematical model describing the human whole body energy metabolism. It takes into account the two central roles of the brain in terms of energy metabolism. The brain is considered as energy consumer as well as regulatory instance. Secondly, we validate our mathematical model by experimental data. Cerebral high-energy phosphate content and peripheral glucose metabolism are measured in healthy men upon neuronal activation induced by transcranial direct current stimulation versus sham stimulation. By parameter estimation we identify model parameters that provide insight into underlying neurophysiological processes. Identified parameters reveal effects of neuronal activity on regulatory mechanisms of systemic glucose metabolism. Results Our examinations support the view that the brain increases its glucose supply upon neuronal activation. The results indicate that the brain supplies itself with energy according to its needs, and preeminence of cerebral energy supply is reflected. This mechanism ensures balanced cerebral energy homeostasis. Conclusions The hypothesis of the central role of the brain in whole body energy homeostasis as active controller is supported. PMID:23988084

  8. A review of vitamin A equivalency of β-carotene in various food matrices for human consumption.

    PubMed

    Van Loo-Bouwman, Carolien A; Naber, Ton H J; Schaafsma, Gertjan

    2014-06-28

    Vitamin A equivalency of β-carotene (VEB) is defined as the amount of ingested β-carotene in μg that is absorbed and converted into 1 μg retinol (vitamin A) in the human body. The objective of the present review was to discuss the different estimates for VEB in various types of dietary food matrices. Different methods are discussed such as mass balance, dose-response and isotopic labelling. The VEB is currently estimated by the US Institute of Medicine (IOM) as 12:1 in a mixed diet and 2:1 in oil. For humans consuming β-carotene dissolved in oil, a VEB between 2:1 and 4:1 is feasible. A VEB of approximately 4:1 is applicable for biofortified cassava, yellow maize and Golden Rice, which are specially bred for human consumption in developing countries. We propose a range of 9:1-16:1 for VEB in a mixed diet that encompasses the IOM VEB of 12:1 and is realistic for a Western diet under Western conditions. For a 'prudent' (i.e. non-Western) diet including a variety of commonly consumed vegetables, a VEB could range from 9:1 to 28:1 in a mixed diet.

  9. Space Radiation and Human Exposures, A Primer.

    PubMed

    Nelson, Gregory A

    2016-04-01

    The space radiation environment is a complex field comprised primarily of charged particles spanning energies over many orders of magnitude. The principal sources of these particles are galactic cosmic rays, the Sun and the trapped radiation belts around the earth. Superimposed on a steady influx of cosmic rays and a steady outward flux of low-energy solar wind are short-term ejections of higher energy particles from the Sun and an 11-year variation of solar luminosity that modulates cosmic ray intensity. Human health risks are estimated from models of the radiation environment for various mission scenarios, the shielding of associated vehicles and the human body itself. Transport models are used to propagate the ambient radiation fields through realistic shielding levels and materials to yield radiation field models inside spacecraft. Then, informed by radiobiological experiments and epidemiology studies, estimates are made for various outcome measures associated with impairments of biological processes, losses of function or mortality. Cancer-associated risks have been formulated in a probabilistic model while management of non-cancer risks are based on permissible exposure limits. This article focuses on the various components of the space radiation environment and the human exposures that it creates.

  10. Modeling In Vivo Interactions of Engineered Nanoparticles in the Pulmonary Alveolar Lining Fluid

    PubMed Central

    Mukherjee, Dwaipayan; Porter, Alexandra; Ryan, Mary; Schwander, Stephan; Chung, Kian Fan; Tetley, Teresa; Zhang, Junfeng; Georgopoulos, Panos

    2015-01-01

    Increasing use of engineered nanomaterials (ENMs) in consumer products may result in widespread human inhalation exposures. Due to their high surface area per unit mass, inhaled ENMs interact with multiple components of the pulmonary system, and these interactions affect their ultimate fate in the body. Modeling of ENM transport and clearance in vivo has traditionally treated tissues as well-mixed compartments, without consideration of nanoscale interaction and transformation mechanisms. ENM agglomeration, dissolution and transport, along with adsorption of biomolecules, such as surfactant lipids and proteins, cause irreversible changes to ENM morphology and surface properties. The model presented in this article quantifies ENM transformation and transport in the alveolar air to liquid interface and estimates eventual alveolar cell dosimetry. This formulation brings together established concepts from colloidal and surface science, physics, and biochemistry to provide a stochastic framework capable of capturing essential in vivo processes in the pulmonary alveolar lining layer. The model has been implemented for in vitro solutions with parameters estimated from relevant published in vitro measurements and has been extended here to in vivo systems simulating human inhalation exposures. Applications are presented for four different ENMs, and relevant kinetic rates are estimated, demonstrating an approach for improving human in vivo pulmonary dosimetry. PMID:26240755

  11. Body water compartments during bed rest: Evaluation of analytical methods

    NASA Technical Reports Server (NTRS)

    Young, H. L.; Juhos, L.; Castle, B. L.; Yusken, J.; Greenleaf, J. E.

    1973-01-01

    Nine healthy young men were studied to determine the reproducibility and interchangeability of the use of radio-iodinated human serum albumin and Evans Blue dye for estimating plasma volume, sodium bromide for extracellular fluid volume, and deuterium oxide for total body water volume. All subjects were tested in a semibasal condition and allowed to rest for at least 30 min. after arriving at the laboratory. The results indicate that there was uniform distribution of I131 and Evans Blue dye 10 min. after injection and of NaBr and D2O 3 hours after oral ingestion; the buildup of residual tracer did not interfere appreciably with the measurement of either or Evans Blue spaces when they are administered at equal intervals, and the buildup of background tracer after ingestion of NaBr and D2O once per week for three consecutive weeks did not affect the accuracy of the measurement. It was found that I131 and Evans Blue may be used interchangeably for estimating plasma volume; for estimating bromide and D2O spaces, one 3-hour equilibrium blood sample gives results similar to the extrapolation of multiple samples.

  12. Dioxin-like polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins, and polychlorinated dibenzofurans in seafood samples from Malaysia: estimated human intake and associated risks.

    PubMed

    Leong, Yin-Hui; Gan, Chee-Yuen; Majid, Mohamed Isa Abdul

    2014-07-01

    A total of 127 and 177 seafood samples from Malaysia were analyzed for polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs), respectively. The World Health Organization-toxic-equivalency quotients (WHO-TEQ) of PCDD/Fs varied from 0.13 to 1.03 pg TEQ g(-1), whereas dl-PCBs ranged from 0.33 to 1.32 pg TEQ g(-1). Based on food-consumption data from the global environment monitoring system-food contamination monitoring and assessment programme, calculated dietary exposures to PCDD/Fs and dl-PCBs from seafood for the general population in Malaysia were 0.042 and 0.098 pg TEQ kg(-1) body weight day(-1), respectively. These estimations were quite different from the values calculated using the Malaysian food-consumption statistics (average of 0.313 and 0.676 pg TEQ kg(-1) body weight day(-1) for PCDD/Fs and PCBs, respectively). However, both of the dietary exposure estimations were lower than the tolerable daily intake recommended by WHO. Thus, it is suggested that seafood from Malaysia does not pose a notable risk to the health of the average consumer.

  13. [ESTIMATION OF IONIZING RADIATION EFFECTIVE DOSES IN THE INTERNATIONAL SPACE STATION CREWS BY THE METHOD OF CALCULATION MODELING].

    PubMed

    Mitrikas, V G

    2015-01-01

    Monitoring of the radiation loading on cosmonauts requires calculation of absorbed dose dynamics with regard to the stay of cosmonauts in specific compartments of the space vehicle that differ in shielding properties and lack means of radiation measurement. The paper discusses different aspects of calculation modeling of radiation effects on human body organs and tissues and reviews the effective dose estimates for cosmonauts working in one or another compartment over the previous period of the International space station operation. It was demonstrated that doses measured by a real or personal dosimeters can be used to calculate effective dose values. Correct estimation of accumulated effective dose can be ensured by consideration for time course of the space radiation quality factor.

  14. Determination of fluorine in biological materials: reaction paper.

    PubMed

    Ophaug, R

    1994-06-01

    Although the fluorine in human tissues may exist in both inorganic and organic (covalently bound) forms, the inorganic fraction is clearly the most relevant for assessing human exposure to, and utilization of, environmental fluoride. There is now general agreement that the inorganic fraction of total tissue fluorine can be accurately determined by a variety of analytical techniques. One of the basic questions considered at this workshop is whether the analysis of a specific tissue or body fluid can provide an estimate of how much of the fluoride to which an individual is exposed actually enters and accumulates in the body. The analysis of hair and nails has been used as an indicator of exposure and utilization for several trace elements, including fluoride. Due to methodological uncertainties regarding sampling and pre-analysis treatment, however, it is presently not possible clearly to distinguish fluoride which is incorporated into hair and nails during formation (endogenous) from that which becomes associated with the tissues following exposure to the environment (exogenous). Consequently, although the fluoride content of hair and nails is clearly increased by environmental exposure to fluoride, the conclusion that these tissues are suitable indicators of fluoride utilization and accumulation in the body is premature.

  15. Fasting - the ultimate diet?

    PubMed

    Johnstone, A M

    2007-05-01

    Adult humans often undertake acute fasts for cosmetic, religious or medical reasons. For example, an estimated 14% of US adults have reported using fasting as a means to control body weight and this approach has long been advocated as an intermittent treatment for gross refractory obesity. There are unique historical data sets on extreme forms of food restriction that give insight into the consequences of starvation or semi-starvation in previously healthy, but usually non-obese subjects. These include documented medical reports on victims of hunger strike, famine and prisoners of war. Such data provide a detailed account on how the body adapts to prolonged starvation. It has previously been shown that fasting for the biblical period of 40 days and 40 nights is well within the overall physiological capabilities of a healthy adult. However, the specific effects on the human body and mind are less clearly documented, either in the short term (hours) or in the longer term (days). This review asks the following three questions, pertinent to any weight-loss therapy, (i) how effective is the regime in achieving weight loss, (ii) what impact does it have on psychology? and finally, (iii) does it work long-term?

  16. Enhancement of natural background gamma-radiation dose around uranium microparticles in the human body.

    PubMed

    Pattison, John E; Hugtenburg, Richard P; Green, Stuart

    2010-04-06

    Ongoing controversy surrounds the adverse health effects of the use of depleted uranium (DU) munitions. The biological effects of gamma-radiation arise from the direct or indirect interaction between secondary electrons and the DNA of living cells. The probability of the absorption of X-rays and gamma-rays with energies below about 200 keV by particles of high atomic number is proportional to the third to fourth power of the atomic number. In such a case, the more heavily ionizing low-energy recoil electrons are preferentially produced; these cause dose enhancement in the immediate vicinity of the particles. It has been claimed that upon exposure to naturally occurring background gamma-radiation, particles of DU in the human body would produce dose enhancement by a factor of 500-1000, thereby contributing a significant radiation dose in addition to the dose received from the inherent radioactivity of the DU. In this study, we used the Monte Carlo code EGSnrc to accurately estimate the likely maximum dose enhancement arising from the presence of micrometre-sized uranium particles in the body. We found that although the dose enhancement is significant, of the order of 1-10, it is considerably smaller than that suggested previously.

  17. δ2H and δ18O of human body water: a GIS model to distinguish residents from non-residents in the contiguous USA.

    PubMed

    Podlesak, David W; Bowen, Gabriel J; O'Grady, Shannon; Cerling, Thure E; Ehleringer, James R

    2012-06-01

    An understanding of the factors influencing the isotopic composition of body water is important to determine the isotopic composition of tissues that are used to reconstruct movement patterns of humans. The δ(2)H and δ(18)O values of body water (δ(2)H(bw) and δ(18)O(bw)) are related to the δ(2)H and δ(18)O values of drinking water (δ(2)H(dw) and δ(18)O(dw)), but clearly distinct because of other factors including the composition of food. Here, we develop a mechanistic geographical information system (GIS) model to produce spatial projections of δ(2)H(bw) and δ(18)O(bw) values for the USA. We investigate the influence of gender, food, and drinking water on the predicted values by comparing them with the published values. The strongest influence on the predicted values was related to the source of δ(2)H(dw) and δ(18)O(dw) values. We combine the model with equations that describe the rate of turnover to produce estimates for the time required for a non-resident to reach an isotopic equilibrium with a resident population.

  18. The error of L5/S1 joint moment calculation in a body-centered non-inertial reference frame when the fictitious force is ignored.

    PubMed

    Xu, Xu; Faber, Gert S; Kingma, Idsart; Chang, Chien-Chi; Hsiang, Simon M

    2013-07-26

    In ergonomics studies, linked segment models are commonly used for estimating dynamic L5/S1 joint moments during lifting tasks. The kinematics data input to these models are with respect to an arbitrary stationary reference frame. However, a body-centered reference frame, which is defined using the position and the orientation of human body segments, is sometimes used to conveniently identify the location of the load relative to the body. When a body-centered reference frame is moving with the body, it is a non-inertial reference frame and fictitious force exists. Directly applying a linked segment model to the kinematics data with respect to a body-centered non-inertial reference frame will ignore the effect of this fictitious force and introduce errors during L5/S1 moment estimation. In the current study, various lifting tasks were performed in the laboratory environment. The L5/S1 joint moments during the lifting tasks were calculated by a linked segment model with respect to a stationary reference frame and to a body-centered non-inertial reference frame. The results indicate that applying a linked segment model with respect to a body-centered non-inertial reference frame will result in overestimating the peak L5/S1 joint moments of the coronal plane, sagittal plane, and transverse plane during lifting tasks by 78%, 2%, and 59% on average, respectively. The instant when the peak moment occurred was delayed by 0.13, 0.03, and 0.09s on average, correspondingly for the three planes. The root-mean-square errors of the L5/S1 joint moment for the three planes are 21Nm, 19Nm, and 9Nm, correspondingly. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Expansion of Microbial Forensics

    PubMed Central

    Schmedes, Sarah E.; Sajantila, Antti

    2016-01-01

    Microbial forensics has been defined as the discipline of applying scientific methods to the analysis of evidence related to bioterrorism, biocrimes, hoaxes, or the accidental release of a biological agent or toxin for attribution purposes. Over the past 15 years, technology, particularly massively parallel sequencing, and bioinformatics advances now allow the characterization of microorganisms for a variety of human forensic applications, such as human identification, body fluid characterization, postmortem interval estimation, and biocrimes involving tracking of infectious agents. Thus, microbial forensics should be more broadly described as the discipline of applying scientific methods to the analysis of microbial evidence in criminal and civil cases for investigative purposes. PMID:26912746

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malfatti, M A; Felton, J S

    A number of carcinogenic heterocyclic amines (PhIP, MeIQx, and DiMeIQx) are produced from the condensation of creatinine, hexoses and amino acids during the cooking of meat (1). There are many variables that impact the production and subsequent ingestion of these compounds in our diet. Temperature, type of meat product, cooking method, doneness, and other factors affect the quantity of these carcinogens consumed by humans. Estimates of ingestion of these carcinogens are 1-20 ng/kg body weight per day (2). Human case control studies that correlate meat consumption from well-done cooking practices with cancer incidence indicate excess tumors for breast, colon, stomach,more » esophagus, and possibly prostate (3-5).« less

  1. Time-frequency analysis of human motion during rhythmic exercises.

    PubMed

    Omkar, S N; Vyas, Khushi; Vikranth, H N

    2011-01-01

    Biomechanical signals due to human movements during exercise are represented in time-frequency domain using Wigner Distribution Function (WDF). Analysis based on WDF reveals instantaneous spectral and power changes during a rhythmic exercise. Investigations were carried out on 11 healthy subjects who performed 5 cycles of sun salutation, with a body-mounted Inertial Measurement Unit (IMU) as a motion sensor. Variance of Instantaneous Frequency (I.F) and Instantaneous Power (I.P) for performance analysis of the subject is estimated using one-way ANOVA model. Results reveal that joint Time-Frequency analysis of biomechanical signals during motion facilitates a better understanding of grace and consistency during rhythmic exercise.

  2. Human biodistribution and dosimetry of [18F]nifene, an α4β2* nicotinic acetylcholine receptor PET tracer.

    PubMed

    Betthauser, Tobey J; Hillmer, Ansel T; Lao, Patrick J; Ehlerding, Emily; Mukherjee, Jogeshwar; Stone, Charles K; Christian, Bradley T

    2017-12-01

    The α4β2* nicotinic acetylcholine receptor (nAChR) system is implicated in many neuropsychiatric pathologies. [ 18 F]Nifene is a positron emission tomography (PET) ligand that has shown promise for in vivo imaging of the α4β2* nAChR system in preclinical models and humans. This work establishes the radiation burden associated with [ 18 F]nifene PET scans in humans. Four human subjects (2M, 2F) underwent whole-body PET/CT scans to determine the human biodistribution of [ 18 F]nifene. Source organs were identified and time-activity-curves (TACs) were extracted from the PET time-series. Dose estimates were calculated for each subject using OLINDA/EXM v1.1. [ 18 F]Nifene was well tolerated by all subjects with no adverse events reported. The mean whole-body effective dose was 28.4±3.8 mSv/MBq without bladder voiding, and 22.6±1.9 mSv/MBq with hourly micturition. The urinary bladder radiation dose limited the maximum injected dose for a single scan to 278 MBq without urinary bladder voiding, and 519 MBq with hourly voiding. [ 18 F]Nifene is a safe PET radioligand for imaging the α4β2* nAChR system in humans. This works presents human internal dosimetry for [ 18 F]nifene in humans for the first time. These results facilitate safe development of future [ 18 F]nifene studies to image the α4β2* nAChR system in humans. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. An assessment of the realism of digital human manikins used for simulation in ergonomics.

    PubMed

    Nérot, Agathe; Skalli, Wafa; Wang, Xuguang

    2015-01-01

    In this study, the accuracy of the joint centres of the manikins generated by RAMSIS and Human Builder (HB), two digital human modelling (DHM) systems widely used in industry for virtual ergonomics simulation, was investigated. Eighteen variously sized females and males were generated from external anthropometric dimensions and six joint centres (knee, hip and four spine joints) were compared with their anatomic locations obtained from the three-dimensional reconstructed bones from a low-dose X-ray system. Both RAMSIS and HB could correctly reproduce external anthropometric dimensions, while the estimation of internal joint centres location presented an average error of 27.6 mm for HB and 38.3 mm for RAMSIS. Differences between both manikins showed that a more realistic kinematic linkage led to better accuracy in joint location. This study opens the way to further research on the relationship between the external body geometry and internal skeleton in order to improve the realism of the internal skeleton of DHMs, especially for a biomechanical analysis requiring information of joint load and muscle force estimation. This study assessed two digital human modelling (DHM) systems widely used in industry for virtual ergonomics. Results support the need of a more realistic human modelling, especially for a biomechanical analysis and a standardisation of DHMs.

  4. The influence of preburial insect access on the decomposition rate.

    PubMed

    Bachmann, Jutta; Simmons, Tal

    2010-07-01

    This study compared total body score (TBS) in buried remains (35 cm depth) with and without insect access prior to burial. Sixty rabbit carcasses were exhumed at 50 accumulated degree day (ADD) intervals. Weight loss, TBS, intra-abdominal decomposition, carcass/soil interface temperature, and below-carcass soil pH were recorded and analyzed. Results showed significant differences (p < 0.001) in decomposition rates between carcasses with and without insect access prior to burial. An approximately 30% enhanced decomposition rate with insects was observed. TBS was the most valid tool in postmortem interval (PMI) estimation. All other variables showed only weak relationships to decomposition stages, adding little value to PMI estimation. Although progress in estimating the PMI for surface remains has been made, no previous studies have accomplished this for buried remains. This study builds a framework to which further comparable studies can contribute, to produce predictive models for PMI estimation in buried human remains.

  5. Relationship between body mass, lean mass, fat mass, and limb bone cross-sectional geometry: Implications for estimating body mass and physique from the skeleton.

    PubMed

    Pomeroy, Emma; Macintosh, Alison; Wells, Jonathan C K; Cole, Tim J; Stock, Jay T

    2018-05-01

    Estimating body mass from skeletal dimensions is widely practiced, but methods for estimating its components (lean and fat mass) are poorly developed. The ability to estimate these characteristics would offer new insights into the evolution of body composition and its variation relative to past and present health. This study investigates the potential of long bone cross-sectional properties as predictors of body, lean, and fat mass. Humerus, femur and tibia midshaft cross-sectional properties were measured by peripheral quantitative computed tomography in sample of young adult women (n = 105) characterized by a range of activity levels. Body composition was estimated from bioimpedance analysis. Lean mass correlated most strongly with both upper and lower limb bone properties (r values up to 0.74), while fat mass showed weak correlations (r ≤ 0.29). Estimation equations generated from tibial midshaft properties indicated that lean mass could be estimated relatively reliably, with some improvement using logged data and including bone length in the models (minimum standard error of estimate = 8.9%). Body mass prediction was less reliable and fat mass only poorly predicted (standard errors of estimate ≥11.9% and >33%, respectively). Lean mass can be predicted more reliably than body mass from limb bone cross-sectional properties. The results highlight the potential for studying evolutionary trends in lean mass from skeletal remains, and have implications for understanding the relationship between bone morphology and body mass or composition. © 2018 The Authors. American Journal of Physical Anthropology Published by Wiley Periodicals, Inc.

  6. Body composition in elderly people: effect of criterion estimates on predictive equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baumgartner, R.N.; Heymsfield, S.B.; Lichtman, S.

    1991-06-01

    The purposes of this study were to determine whether there are significant differences between two- and four-compartment model estimates of body composition, whether these differences are associated with aqueous and mineral fractions of the fat-free mass (FFM); and whether the differences are retained in equations for predicting body composition from anthropometry and bioelectric resistance. Body composition was estimated in 98 men and women aged 65-94 y by using a four-compartment model based on hydrodensitometry, {sup 3}H{sub 2}O dilution, and dual-photon absorptiometry. These estimates were significantly different from those obtained by using Siri's two-compartment model. The differences were associated significantly (Pmore » less than 0.0001) with variation in the aqueous fraction of FFM. Equations for predicting body composition from anthropometry and resistance, when calibrated against two-compartment model estimates, retained these systematic errors. Equations predicting body composition in elderly people should be calibrated against estimates from multicompartment models that consider variability in FFM composition.« less

  7. Studies on time of death estimation in the early post mortem period -- application of a method based on eyeball temperature measurement to human bodies.

    PubMed

    Kaliszan, Michał

    2013-09-01

    This paper presents a verification of the thermodynamic model allowing an estimation of the time of death (TOD) by calculating the post mortem interval (PMI) based on a single eyeball temperature measurement at the death scene. The study was performed on 30 cases with known PMI, ranging from 1h 35min to 5h 15min, using pin probes connected to a high precision electronic thermometer (Dostmann-electronic). The measured eye temperatures ranged from 20.2 to 33.1°C. Rectal temperature was measured at the same time and ranged from 32.8 to 37.4°C. Ambient temperatures which ranged from -1 to 24°C, environmental conditions (still air to light wind) and the amount of hair on the head were also recorded every time. PMI was calculated using a formula based on Newton's law of cooling, previously derived and successfully tested in comprehensive studies on pigs and a few human cases. Thanks to both the significantly faster post mortem decrease of eye temperature and a residual or nonexistent plateau effect in the eye, as well as practically no influence of body mass, TOD in the human death cases could be estimated with good accuracy. The highest TOD estimation error during the post mortem intervals up to around 5h was 1h 16min, 1h 14min and 1h 03min, respectively in three cases among 30, while for the remaining 27 cases it was not more than 47min. The mean error for all 30 cases was ±31min. All that indicates that the proposed method is of quite good precision in the early post mortem period, with an accuracy of ±1h for a 95% confidence interval. On the basis of the presented method, TOD can be also calculated at the death scene with the use of a proposed portable electronic device (TOD-meter). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Calculated SAR distributions in a human voxel phantom due to the reflection of electromagnetic fields from a ground plane between 65 MHz and 2 GHz

    NASA Astrophysics Data System (ADS)

    Findlay, R. P.; Dimbylow, P. J.

    2008-05-01

    If an electromagnetic field is incident normally onto a perfectly conducting ground plane, the field is reflected back into the domain. This produces a standing wave above the ground plane. If a person is present within the domain, absorption of the field in the body may cause problems regarding compliance with electromagnetic guidelines. To investigate this, the whole-body averaged specific energy absorption rate (SAR), localised SAR and ankle currents in the voxel model NORMAN have been calculated for a variety of these exposures under grounded conditions. The results were normalised to the spatially averaged field, a technique used to determine a mean value for comparison with guidelines when the field varies along the height of the body. Additionally, the external field values required to produce basic restrictions for whole-body averaged SAR have been calculated. It was found that in all configurations studied, the ICNIRP reference levels and IEEE MPEs provided a conservative estimate of these restrictions.

  9. Estimating in vivo airway surface liquid concentration in trials of inhaled antibiotics.

    PubMed

    Hasan, M A; Lange, C F

    2007-01-01

    Antibiotic drugs exhibit concentration dependence in their efficacy. Therefore, ensuring appropriate concentration of these drugs in the relevant body fluid is important for obtaining the desired therapeutic and physiological action. Until recently there had been no suitable method available to measure or estimate concentration of drugs in the human airways resulting from inhaled aerosols or to determine the amount of inhaled antibiotics required to ensure minimum inhibitory concentration of a drug in the airway surface liquid (ASL). In this paper a numerical method is used for estimating local concentration of inhaled pharmaceutical aerosols in different generations of the human tracheobronchial airways. The method utilizes a mathematical lung deposition model to estimate amounts of aerosols depositing in different lung generations, and a recent ASL model along with deposition results to assess the concentration of deposited drugs immediately following inhalation. Examples of concentration estimates for two case studies: one for the antibiotic tobramycin against Pseudomonas aeruginosa, and another for taurolidine against Burkholderia cepacia are presented. The aerosol characteristics, breathing pattern and properties of nebulized solutions were adopted from two recent clinical studies on efficacy of these drugs in cystic fibrosis (CF) patients and from other sources in the literature. While the clinically effective tobramycin showed a concentration higher than the required in vivo concentration, that for the ineffective taurolidine was found to be below the speculated required in vivo concentration. Results of this study thus show that the mathematical ASL model combined with the lung deposition model can be an effective tool for helping decide the optimum dosage of inhaled antibiotic drugs delivered during human clinical trials.

  10. A MODEL TO EVALUATE PAST EXPOSURE TO 2,3,7,8 ...

    EPA Pesticide Factsheets

    Data from several studies suggest that concentrations of dioxins rose in the environment from the 1930s to about the 1960s/70s and have been declining over the last decade or two. The most direct evidence of this trend comes from lake core sediments, which can be used to estimate past atmospheric depositions of dioxins. The primary source of human exposure to dioxins is through the food supply. The pathway relating atmospheric depositions to concentrations in food is quite complex, and accordingly, it is not known to what extent the trend in human exposure mirrors the trend in atmospheric depositions. This paper describes an attempt to statistically reconstruct the pattern of past human exposure to the most toxic dioxin congener, 2,3,7,8-TCDD (abbreviated TCDD), through use of a simple pharmacokinetic (PK) model which included a time-varying TCDD exposure dose. This PK model was fit to TCDD body burden data (i.e., TCDD concentrations in lipid) from five U.S. studies dating from 1972 to 1987 and covering a wide age range. A Bayesian statistical approach was used to fit TCDD exposure; model parameters other than exposure were all previously known or estimated from other data sources. The primary results of the analysis are as follows: 1.) use of a time-varying exposure dose provided a far better fit to the TCDD body burden data than did using a dose that was constant over time; this is strong evidence that exposure to TCDD has, in fact, varied during the

  11. Changing guards: time to move beyond body mass index for population monitoring of excess adiposity.

    PubMed

    Tanamas, S K; Lean, M E J; Combet, E; Vlassopoulos, A; Zimmet, P Z; Peeters, A

    2016-07-01

    With the obesity epidemic, and the effects of aging populations, human phenotypes have changed over two generations, possibly more dramatically than in other species previously. As obesity is an important and growing hazard for population health, we recommend a systematic evaluation of the optimal measure(s) for population-level excess body fat. Ideal measure(s) for monitoring body composition and obesity should be simple, as accurate and sensitive as possible, and provide good categorization of related health risks. Combinations of anthropometric markers or predictive equations may facilitate better use of anthropometric data than single measures to estimate body composition for populations. Here, we provide new evidence that increasing proportions of aging populations are at high health-risk according to waist circumference, but not body mass index (BMI), so continued use of BMI as the principal population-level measure substantially underestimates the health-burden from excess adiposity. © The Author 2015. Published by Oxford University Press on behalf of the Association of Physicians. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Variations in the ceramide profile in different seasons and regions of the body contribute to stratum corneum functions.

    PubMed

    Ishikawa, Junko; Shimotoyodome, Yoshie; Ito, Shotaro; Miyauchi, Yuki; Fujimura, Tsutomu; Kitahara, Takashi; Hase, Tadashi

    2013-03-01

    The objective of this study was to clarify variations of the ceramide (CER) profile in human stratum corneum (SC) in different seasons and in different regions of the body and to estimate the contributions of CERs to the SC barrier and water-holding functions. Based on the information that there are great variations of SC functions among body sites, we compared the CER profiles obtained from ten different anatomical sites in healthy Japanese males in four seasons. Not only the physiological parameters of skin but also the CER profile showed body region and seasonal variations. The total CER level, the CER composition and the C34-CER[NS] species displayed strong correlations with the values of transepidermal water loss and capacitance throughout the body. Especially in the cheek, a strong correlation between the capacitance and the CER profile was observed. There were seasonal variations of the CER profile in the lip, upper arm and palm. Our results indicate that regional and seasonal variations of the CER profile may contribute to SC functions.

  13. Economic Estimation of the Losses Caused by Surface Water Pollution Accidents in China From the Perspective of Water Bodies' Functions.

    PubMed

    Yao, Hong; You, Zhen; Liu, Bo

    2016-01-22

    The number of surface water pollution accidents (abbreviated as SWPAs) has increased substantially in China in recent years. Estimation of economic losses due to SWPAs has been one of the focuses in China and is mentioned many times in the Environmental Protection Law of China promulgated in 2014. From the perspective of water bodies' functions, pollution accident damages can be divided into eight types: damage to human health, water supply suspension, fishery, recreational functions, biological diversity, environmental property loss, the accident's origin and other indirect losses. In the valuation of damage to people's life, the procedure for compensation of traffic accidents in China was used. The functional replacement cost method was used in economic estimation of the losses due to water supply suspension and loss of water's recreational functions. Damage to biological diversity was estimated by recovery cost analysis and damage to environmental property losses were calculated using pollutant removal costs. As a case study, using the proposed calculation procedure the economic losses caused by the major Songhuajiang River pollution accident that happened in China in 2005 have been estimated at 2263 billion CNY. The estimated economic losses for real accidents can sometimes be influenced by social and political factors, such as data authenticity and accuracy. Besides, one or more aspects in the method might be overestimated, underrated or even ignored. The proposed procedure may be used by decision makers for the economic estimation of losses in SWPAs. Estimates of the economic losses of pollution accidents could help quantify potential costs associated with increased risk sources along lakes/rivers but more importantly, highlight the value of clean water to society as a whole.

  14. Comparison of methods to assess change in children’s body composition123

    PubMed Central

    Elberg, Jane; McDuffie, Jennifer R; Sebring, Nancy G; Salaita, Christine; Keil, Margaret; Robotham, Delphine; Reynolds, James C; Yanovski, Jack A

    2008-01-01

    Background Little is known about how simpler and more available methods to measure change in body fatness compare with criterion methods such as dual-energy X-ray absorptiometry (DXA) in children. Objective Our objective was to determine the ability of air-displacement plethysmography (ADP) and formulas based on triceps skinfold thickness (TSF) and bioelectrical impedance analysis (BIA) to estimate changes in body fat over time in children. Design Eighty-six nonoverweight and overweight boys (n = 34) and girls (n = 52) with an average age of 11.0 ± 2.4 y underwent ADP, TSF measurement, BIA, and DXA to estimate body fatness at baseline and 1 ± 0.3 y later. Recent equations were used to estimate percentage body fat by TSF measurement (Dezenberg equation) and by BIA (Suprasongsin and Lewy equations). Percentage body fat estimates by ADP, TSF measurement, and BIA were compared with those by DXA. Results All methods were highly correlated with DXA (P < 0.001). No mean bias for estimates of percentage body fat change was found for ADP (Siri equation) compared with DXA for all subjects examined together, and agreement between body fat estimation by ADP and DXA did not vary with race or sex. Magnitude bias was present for ADP relative to DXA (P < 0.01). Estimates of change in percentage body fat were systematically overestimated by BIA equations (1.37 ± 6.98%; P < 0.001). TSF accounted for only 13% of the variance in percentage body fat change. Conclusion Compared with DXA, there appears to be no noninvasive and simple method to measure changes in children’s percentage body fat accurately and precisely, but ADP performed better than did TSF or BIA. ADP could prove useful for measuring changes in adiposity in children. PMID:15213029

  15. Subject-specific body segment parameter estimation using 3D photogrammetry with multiple cameras

    PubMed Central

    Morris, Mark; Sellers, William I.

    2015-01-01

    Inertial properties of body segments, such as mass, centre of mass or moments of inertia, are important parameters when studying movements of the human body. However, these quantities are not directly measurable. Current approaches include using regression models which have limited accuracy: geometric models with lengthy measuring procedures or acquiring and post-processing MRI scans of participants. We propose a geometric methodology based on 3D photogrammetry using multiple cameras to provide subject-specific body segment parameters while minimizing the interaction time with the participants. A low-cost body scanner was built using multiple cameras and 3D point cloud data generated using structure from motion photogrammetric reconstruction algorithms. The point cloud was manually separated into body segments, and convex hulling applied to each segment to produce the required geometric outlines. The accuracy of the method can be adjusted by choosing the number of subdivisions of the body segments. The body segment parameters of six participants (four male and two female) are presented using the proposed method. The multi-camera photogrammetric approach is expected to be particularly suited for studies including populations for which regression models are not available in literature and where other geometric techniques or MRI scanning are not applicable due to time or ethical constraints. PMID:25780778

  16. Environmental Stability and Infectivity of Hepatitis C Virus (HCV) in Different Human Body Fluids.

    PubMed

    Pfaender, Stephanie; Helfritz, Fabian A; Siddharta, Anindya; Todt, Daniel; Behrendt, Patrick; Heyden, Julia; Riebesehl, Nina; Willmann, Wiebke; Steinmann, Joerg; Münch, Jan; Ciesek, Sandra; Steinmann, Eike

    2018-01-01

    Background: Hepatitis C virus (HCV) is a hepatotropic, blood-borne virus, but in up to one-third of infections of the transmission route remained unidentified. Viral genome copies of HCV have been identified in several body fluids, however, non-parental transmission upon exposure to contaminated body fluids seems to be rare. Several body fluids, e.g., tears and saliva, are renowned for their antimicrobial and antiviral properties, nevertheless, HCV stability has never been systematically analyzed in those fluids. Methods: We used state of the art infectious HCV cell culture techniques to investigate the stability of HCV in different body fluids to estimate the potential risk of transmission via patient body fluid material. In addition, we mimicked a potential contamination of HCV in tear fluid and analyzed which impact commercially available contact lens solutions might have in such a scenario. Results: We could demonstrate that HCV remains infectious over several days in body fluids like tears, saliva, semen, and cerebrospinal fluid. Only hydrogen-peroxide contact lens solutions were able to efficiently inactivate HCV in a suspension test. Conclusion: These results indicate that HCV, once it is present in various body fluids of infected patients, remains infective and could potentially contribute to transmission upon direct contact.

  17. Subject-specific body segment parameter estimation using 3D photogrammetry with multiple cameras.

    PubMed

    Peyer, Kathrin E; Morris, Mark; Sellers, William I

    2015-01-01

    Inertial properties of body segments, such as mass, centre of mass or moments of inertia, are important parameters when studying movements of the human body. However, these quantities are not directly measurable. Current approaches include using regression models which have limited accuracy: geometric models with lengthy measuring procedures or acquiring and post-processing MRI scans of participants. We propose a geometric methodology based on 3D photogrammetry using multiple cameras to provide subject-specific body segment parameters while minimizing the interaction time with the participants. A low-cost body scanner was built using multiple cameras and 3D point cloud data generated using structure from motion photogrammetric reconstruction algorithms. The point cloud was manually separated into body segments, and convex hulling applied to each segment to produce the required geometric outlines. The accuracy of the method can be adjusted by choosing the number of subdivisions of the body segments. The body segment parameters of six participants (four male and two female) are presented using the proposed method. The multi-camera photogrammetric approach is expected to be particularly suited for studies including populations for which regression models are not available in literature and where other geometric techniques or MRI scanning are not applicable due to time or ethical constraints.

  18. Evolving Concepts on Adjusting Human Resting Energy Expenditure Measurements for Body Size

    PubMed Central

    Heymsfield, Steven B.; Thomas, Diana; Bosy-Westphal, Anja; Shen, Wei; Peterson, Courtney M.; Müller, Manfred J.

    2012-01-01

    Establishing if an adult’s resting energy expenditure (REE) is high or low for their body size is a pervasive question in nutrition research. Early workers applied body mass and height as size measures and formulated the Surface Law and Kleiber’s Law, although each has limitations when adjusting REE. Body composition methods introduced during the mid-twentieth century provided a new opportunity to identify metabolically homogeneous “active” compartments. These compartments all show improved correlations with REE estimates over body mass-height approaches, but collectively share a common limitation: REE-body composition ratios are not “constant” but vary across men and women and with race, age, and body size. The now-accepted alternative to ratio-based norms is to adjust for predictors by applying regression models to calculate “residuals” that establish if a REE is relatively high or low. The distinguishing feature of statistical REE-body composition models is a “non-zero” intercept of unknown origin. The recent introduction of imaging methods has allowed development of physiological tissue-organ based REE prediction models. Herein we apply these imaging methods to provide a mechanistic explanation, supported by experimental data, for the non-zero intercept phenomenon and in that context propose future research directions for establishing between subject differences in relative energy metabolism. PMID:22863371

  19. Scaling left ventricular mass in adolescent boys aged 11-15 years.

    PubMed

    Valente-Dos-Santos, João; Coelho-E-Silva, Manuel J; Ferraz, António; Castanheira, Joaquim; Ronque, Enio R; Sherar, Lauren B; Elferink-Gemser, Marije T; Malina, Robert M

    2014-01-01

    Normalizing left ventricular mass (LVM) for inter-individual variation in body size is a central issue in human biology. During the adolescent growth spurt, variability in body size descriptors needs to be interpreted in combination with biological maturation. To examine the contribution of biological maturation, stature, sitting height, body mass, fat-free mass (FFM) and fat mass (FM) to inter-individual variability in LVM in boys, using proportional allometric modelling. The cross-sectional sample included 110 boys of 11-15 years (12.9-1.0 years). Stature, sitting height, body mass, cardiac chamber dimensions and LVM were measured. Age at peak height velocity (APHV) was predicted and used as an indicator of biological maturation. Percentage fat was estimated from triceps and subscapular skinfolds; FM and FFM were derived. Exponents for body size descriptors were k = 2.33 for stature, k = 2.18 for sitting height, k = 0.68 for body mass, k = 0.17 for FM and k = 0.80 for FFM (adjusted R(2 )= 19-62%). The combination of body descriptors and APHV increased the explained variance in LVM (adjusted R(2)( )= 56-69%). Stature, FM and FFM are the best combination for normalizing LVM in adolescent boys; when body composition is not available, an indicator of biological maturity should be included with stature.

  20. Occupant kinematics and estimated effectiveness of side airbags in pole side impacts using a human FE model with internal organs.

    PubMed

    Hayashi, Shigeki; Yasuki, Tsuyoshi; Kitagawa, Yuichi

    2008-11-01

    When a car collides against a pole-like obstacle, the deformation pattern of the vehicle body-side tends to extend to its upper region. A possible consequence is an increase of loading to the occupant thorax. Many studies have been conducted to understand human thoracic responses to lateral loading, and injury criteria have been developed based on the results. However, injury mechanisms, especially those of internal organs, are not well understood. A human body FE model was used in this study to simulate occupant kinematics in a pole side impact. Internal organ parts were introduced into the torso model, including their geometric features, material properties and connections with other tissues. The mechanical responses of the model were validated against PMHS data in the literature. Although injury criterion for each organ has not been established, pressure level and its changes can be estimated from the organ models. Finite element simulations were conducted assuming a case where a passenger vehicle collides against a pole at 29km/h. Occupant kinematics, force-deformation responses and pressure levels were compared between cases with and without side airbag deployment. The results indicated that strain to the ribs and pressure to the organs was smaller with side airbag deployment. The side airbag widened the contact area at the torso, helping to distribute the force to the shoulder, arm and chest. Such distributed force helped generate relatively smaller deformation in the ribs. Furthermore, the side airbag deployment helped restrict the spine displacement. The smaller displacement contributed to lowering the magnitude of contact force between the torso and the door. The study also examined the correlations between the pressure levels in the internal organs, rib deflection, and V*C of chest. The study found that the V*C(t) peak appeared to be synchronized with the organ pressure peak, suggesting that the pressure level of the internal organs could be one possible indicator to estimate their injury risk.

  1. [An interactive three-dimensional model of the human body].

    PubMed

    Liem, S L

    2009-01-01

    Driven by advanced computer technology, it is now possible to show the human anatomy on a computer. On the internet, the Visible Body programme makes it possible to navigate in all directions through the anatomical structures of the human body, using mouse and keyboard. Visible Body is a wonderful tool to give insight in the human structures, body functions and organs.

  2. Human resources requirements for highly active antiretroviral therapy scale-up in Malawi.

    PubMed

    Muula, Adamson S; Chipeta, John; Siziya, Seter; Rudatsikira, Emmanuel; Mataya, Ronald H; Kataika, Edward

    2007-12-19

    Twelve percent of the adult population in Malawi is estimated to be HIV infected. About 15% to 20% of these are in need of life saving antiretroviral therapy. The country has a public sector-led antiretroviral treatment program both in the private and public health sectors. Estimation of the clinical human resources needs is required to inform the planning and distribution of health professionals. We obtained data on the total number of patients on highly active antiretroviral treatment program from the Malawi National AIDS Commission and Ministry of Health, HIV Unit, and the number of registered health professionals from the relevant regulatory bodies. We also estimated number of health professionals required to deliver highly active antiretroviral therapy (HAART) using estimates of human resources from the literature. We also obtained data from the Ministry of Health on the actual number of nurses, clinical officers and medical doctors providing services in HAART clinics. We then made comparisons between the human resources situation on the ground and the theoretical estimates based on explicit assumptions. There were 610 clinicians (396 clinical officers and 214 physicians), 44 pharmacists and 98 pharmacy technicians and 7264 nurses registered in Malawi. At the end of March 2007 there were 85 clinical officer and physician full-time equivalents (FTEs) and 91 nurse FTEs providing HAART to 95,674 patients. The human resources used for the delivery of HAART comprised 13.9% of all clinical officers and physicians and 1.1% of all nurses. Using the estimated numbers of health professionals from the literature required 15.7-31.4% of all physicians and clinical officers, 66.5-199.3% of all pharmacists and pharmacy technicians and 2.6 to 9.2% of all the available nurses. To provide HAART to all the 170,000 HIV infected persons estimated as clinically eligible would require 4.7% to 16.4% of the total number of nurses, 118.1% to 354.2% of all the available pharmacists and pharmacy technicians and 27.9% to 55.7% of all clinical officers and physicians. The actual number of health professionals working in the delivery of HAART in the clinics represented 44% to 88.8% (for clinical officers and medical doctors) and 13.6% and 47.6% (for nurses), of what would have been needed based on the literature estimation. HAART provision is a labour intensive exercise. Although these data are insufficient to determine whether HAART scale-up has resulted in the weakening or strengthening of the health systems in Malawi, the human resources requirements for HAART scale-up are significant. Malawi is using far less human resources than would be estimated based on the literature from other settings. The impact of HAART scale-up on the overall delivery of health services should be assessed.

  3. Aerosol deposition in the human respiratory tract

    NASA Astrophysics Data System (ADS)

    Winchester, John W.; Jones, Donald L.; Mu-tian, Bi

    1984-04-01

    Rising sulfur dioxide emissions from increased coal combustion present risks, not only of acid rain, but also to health by inhalation of the SO 2 and acid to the lung. We are investigating human inhalation of ppm SO 2 concentrations mixed with aerosol of submicrometer aqueous salt droplets to determine the effects on lung function and body chemistry. Unlike some investigators, we emphasize ammonium sulfate and trace element aerosol composition which simulates ambient air; aerosol pH, relative humidity, and temperature control to reveal gas-particle reaction mechanisms; and dose estimates from length of exposure, SO 2 concentration, and a direct measurement of respiratory deposition of aerosol as a function of particle size by cascade impactor sampling and elemental analysis by PIXE. Exposures, at rest or during exercise, are in a walk-in chamber at body temperature and high humidity to simulate Florida's summer climate. Lung function measurement by spirometry is carried out immediately after exposure. The results are significant in relating air quality to athletic performance and to public health in the southeastern United States.

  4. Human movement analysis using stereophotogrammetry. Part 1: theoretical background.

    PubMed

    Cappozzo, Aurelio; Della Croce, Ugo; Leardini, Alberto; Chiari, Lorenzo

    2005-02-01

    This paper sets the stage for a series of reviews dealing with the problems associated with the reconstruction and analysis of in vivo skeletal system kinematics using optoelectronic stereophotogrammetric data. Instantaneous bone position and orientation and joint kinematic variable estimations are addressed in the framework of rigid body mechanics. The conceptual background to these exercises is discussed. Focus is placed on the experimental and analytical problem of merging the information relative to movement and that relative to the morphology of the anatomical body parts of interest. The various global and local frames that may be used in this context are defined. Common anatomical and mathematical conventions that can be used to describe joint kinematics are illustrated in a comparative fashion. The authors believe that an effort to systematize the different theoretical and experimental approaches to the problems involved and related nomenclatures, as currently reported in the literature, is needed to facilitate data and knowledge sharing, and to provide renewed momentum for the advancement of human movement analysis.

  5. Differences in pediatric vertical ground reaction force between planovalgus and neutrally aligned feet.

    PubMed

    Pauk, Jolanta; Szymul, Joanna

    2014-01-01

    Ground reaction forces (GRF) reflect the force history of human body contact with the ground. The purpose of this study was to explore human gait abnormalities due to planovalgus by comparing vertical GRF data between individuals with planovalgus and those with neutrally aligned feet. Second we estimated associations between various measurements and vertical GRF parameters in a pediatric population. Boys and girls between the ages of 4 and 18 years (72 planovalgus feet and 74 neutrally aligned feet) took part in this study. Ground reaction forces were recorded by two Kistler platforms and normalized to body weight. Comparison of vertical GRF between planovalgus and neutrally aligned feet suggests that the first and the second peaks of vertical force (Fz1, Fz2) are most affected by planovalgus. The results also indicate that neutrally aligned feet display a different ground reaction force pattern than planovalgus, and that differences between boys and girls may be observed. The shape of the vertical GRF curve can help in clinical interpretation of abnormal gait.

  6. Polonium assimilation and retention in mule deer and pronghorn antelope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sejkora, K.J.

    Excretion kinetics and tissue distribution of polonium-210 in mule deer and pronghorn were studied. Each animal in a captive herd of 7 mule deer and 2 pronghorn received an intraruminal injection of 4.4 ..mu..Ci of polonium chloride. Feces and urine were collected periodically over a 43-day period and daily excretion rate for each pathway was regressed as a function of time. Assimilation fractions of 0.40 and 0.51 were calculated for mule deer (n=2) and 0.60 for a pronghorn. Body burden retention functions were calculated from integrated excretion rate functions. Polonium burdens in muscle, liver, and kidney were calculated as amore » fraction of body burden from serially-sacrificed animals. Background tissue burdens in mule deer were comparable to those of other ruminants reported in the literature. Hypothetical cases were assumed which combined feeding rate of mule deer, forage concentrations of polonium, retention function, tissue burden fraction, and human intake to estimate human radiation dose. 26 references.« less

  7. Implications of human tissue studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kathren, R.L.

    1986-10-01

    Through radiochemical analysis of voluntary tissue donations, the United States Transuranium and Uranium Registries are gaining improved understanding of the distribution and biokinetics of actinide elements in occupationally exposed persons. Evaluation of the first two whole body contributions to the Transuranium Registry revealed an inverse proportionality between actinide concentration and bone ash fraction. The analysis of a whole body with a documented /sup 241/Am deposition indicated a significantly shorter half-time in liver and a greater fraction resident in the skeleton than predicted by existing models. Other studies of the Registries are designed to evaluate in vivo estimates of actinide depositionmore » with those derived from postmortem tissue analysis, compare results of animal experiments with human data, and reviw histopathologic slides for tissue toxicity that might be attributable to exposure to uranium and the transuranic elements. The implications of these recent findings and other work of the Registries are discussed from the standpoint of their potential impact on biokinetic modeling, internal dose assessment, safety standards, and operational health physics practices.« less

  8. Simultaneous voltammetric determination of prednisone and prednisolone in human body fluids.

    PubMed

    Goyal, Rajendra N; Bishnoi, Sunita

    2009-08-15

    A sensitive, rapid and reliable electrochemical method based on voltammetry at single wall carbon nanotube (SWNT) modified edge plane pyrolytic graphite electrode (EPPGE) is proposed for the simultaneous determination of prednisolone and prednisone in human body fluids and pharmaceutical preparations. The electrochemical response of both the drugs was evaluated by osteryoung square wave voltammetry (OSWV) in phosphate buffer medium of pH 7.2. The modified electrode exhibited good electrocatalytic properties towards prednisone and prednisolone reduction with a peak potential of approximately -1230 and approximately -1332 mV respectively. The concentration versus peak current plots were linear for both the analytes in the range 0.01-100 microM and the detection limit (3 sigma/slope) observed for prednisone and prednisolone were 0.45 x 10(-8), 0.90 x 10(-8)M, respectively. The results of the quantitative estimation of prednisone and prednisolone in biological fluids were also compared with HPLC and the results were in good agreement.

  9. Human induced rotation and reorganization of the brain of domestic dogs.

    PubMed

    Roberts, Taryn; McGreevy, Paul; Valenzuela, Michael

    2010-07-26

    Domestic dogs exhibit an extraordinary degree of morphological diversity. Such breed-to-breed variability applies equally to the canine skull, however little is known about whether this translates to systematic differences in cerebral organization. By looking at the paramedian sagittal magnetic resonance image slice of canine brains across a range of animals with different skull shapes (N = 13), we found that the relative reduction in skull length compared to width (measured by Cephalic Index) was significantly correlated to a progressive ventral pitching of the primary longitudinal brain axis (r = 0.83), as well as with a ventral shift in the position of the olfactory lobe (r = 0.81). Furthermore, these findings were independent of estimated brain size or body weight. Since brachycephaly has arisen from generations of highly selective breeding, this study suggests that the remarkable diversity in domesticated dogs' body shape and size appears to also have led to human-induced adaptations in the organization of the canine brain.

  10. Noninvasive monitoring local variations of fever and edema on human: potential for point-of-care inflammation assessment

    NASA Astrophysics Data System (ADS)

    Li, Zebin; Li, Xianglin; Li, Ting

    2018-02-01

    Tissue inflammation is often accompanied by fever and edema, which are common and troublesome problems that probably trigger disability, lymphangitis, cosmetic deformity and cellulitis. Here we developed a device, which can measure concentration and temperature variations of water in local human body by extended near infrared spectroscopy in 900 1000 nm wavelength range. An experiment of four steps incremental cycling exercise was designed to change tissue water concentration and temperature of subjects. Body temperature was also estimated by tympanic thermometer and surface thermometer as comparisons during the experiment. In the stage of recovery after exercise, the signal detected by custom device is similar to tympanic thermometer at the beginning, but it is closer to the temperature of surface later. In particular, this signal shows a better linearity, and a significant change when the exercise was suspended. This study demonstrated the potential of optical touch-sensing for inflammation severity monitoring by measuring water concentration and temperature variations in local lesions.

  11. Double-path acquisition of pulse wave transit time and heartbeat using self-mixing interferometry

    NASA Astrophysics Data System (ADS)

    Wei, Yingbin; Huang, Wencai; Wei, Zheng; Zhang, Jie; An, Tong; Wang, Xiulin; Xu, Huizhen

    2017-06-01

    We present a technique based on self-mixing interferometry for acquiring the pulse wave transit time (PWTT) and heartbeat. A signal processing method based on Continuous Wavelet Transform and Hilbert Transform is applied to extract potentially useful information in the self-mixing interference (SMI) signal, including PWTT and heartbeat. Then, some cardiovascular characteristics of the human body are easily acquired without retrieving the SMI signal by complicated algorithms. Experimentally, the PWTT is measured on the finger and the toe of the human body using double-path self-mixing interferometry. Experimental statistical data show the relation between the PWTT and blood pressure, which can be used to estimate the systolic pressure value by fitting. Moreover, the measured heartbeat shows good agreement with that obtained by a photoplethysmography sensor. The method that we demonstrate, which is based on self-mixing interferometry with significant advantages of simplicity, compactness and non-invasion, effectively illustrates the viability of the SMI technique for measuring other cardiovascular signals.

  12. Improved predictive ability of climate-human-behaviour interactions with modifications to the COMFA outdoor energy budget model.

    PubMed

    Vanos, J K; Warland, J S; Gillespie, T J; Kenny, N A

    2012-11-01

    The purpose of this paper is to implement current and novel research techniques in human energy budget estimations to give more accurate and efficient application of models by a variety of users. Using the COMFA model, the conditioning level of an individual is incorporated into overall energy budget predictions, giving more realistic estimations of the metabolism experienced at various fitness levels. Through the use of VO(2) reserve estimates, errors are found when an elite athlete is modelled as an unconditioned or a conditioned individual, giving budgets underpredicted significantly by -173 and -123 W m(-2), respectively. Such underprediction can result in critical errors regarding heat stress, particularly in highly motivated individuals; thus this revision is critical for athletic individuals. A further improvement in the COMFA model involves improved adaptation of clothing insulation (I (cl)), as well clothing non-uniformity, with changing air temperature (T (a)) and metabolic activity (M (act)). Equivalent T (a) values (for I (cl) estimation) are calculated in order to lower the I (cl) value with increasing M (act) at equal T (a). Furthermore, threshold T (a) values are calculated to predict the point at which an individual will change from a uniform I (cl) to a segmented I (cl) (full ensemble to shorts and a T-shirt). Lastly, improved relative velocity (v (r)) estimates were found with a refined equation accounting for the degree angle of wind to body movement. Differences between the original and improved v (r) equations increased with higher wind and activity speeds, and as the wind to body angle moved away from 90°. Under moderate microclimate conditions, and wind from behind a person, the convective heat loss and skin temperature estimates were 47 W m(-2) and 1.7°C higher when using the improved v (r) equation. These model revisions improve the applicability and usability of the COMFA energy budget model for subjects performing physical activity in outdoor environments. Application is possible for other similar energy budget models, and within various urban and rural environments.

  13. Improved predictive ability of climate-human-behaviour interactions with modifications to the COMFA outdoor energy budget model

    NASA Astrophysics Data System (ADS)

    Vanos, J. K.; Warland, J. S.; Gillespie, T. J.; Kenny, N. A.

    2012-11-01

    The purpose of this paper is to implement current and novel research techniques in human energy budget estimations to give more accurate and efficient application of models by a variety of users. Using the COMFA model, the conditioning level of an individual is incorporated into overall energy budget predictions, giving more realistic estimations of the metabolism experienced at various fitness levels. Through the use of VO2 reserve estimates, errors are found when an elite athlete is modelled as an unconditioned or a conditioned individual, giving budgets underpredicted significantly by -173 and -123 W m-2, respectively. Such underprediction can result in critical errors regarding heat stress, particularly in highly motivated individuals; thus this revision is critical for athletic individuals. A further improvement in the COMFA model involves improved adaptation of clothing insulation ( I cl), as well clothing non-uniformity, with changing air temperature ( T a) and metabolic activity ( M act). Equivalent T a values (for I cl estimation) are calculated in order to lower the I cl value with increasing M act at equal T a. Furthermore, threshold T a values are calculated to predict the point at which an individual will change from a uniform I cl to a segmented I cl (full ensemble to shorts and a T-shirt). Lastly, improved relative velocity ( v r) estimates were found with a refined equation accounting for the degree angle of wind to body movement. Differences between the original and improved v r equations increased with higher wind and activity speeds, and as the wind to body angle moved away from 90°. Under moderate microclimate conditions, and wind from behind a person, the convective heat loss and skin temperature estimates were 47 W m-2 and 1.7°C higher when using the improved v r equation. These model revisions improve the applicability and usability of the COMFA energy budget model for subjects performing physical activity in outdoor environments. Application is possible for other similar energy budget models, and within various urban and rural environments.

  14. A robust and accurate center-frequency estimation (RACE) algorithm for improving motion estimation performance of SinMod on tagged cardiac MR images without known tagging parameters.

    PubMed

    Liu, Hong; Wang, Jie; Xu, Xiangyang; Song, Enmin; Wang, Qian; Jin, Renchao; Hung, Chih-Cheng; Fei, Baowei

    2014-11-01

    A robust and accurate center-frequency (CF) estimation (RACE) algorithm for improving the performance of the local sine-wave modeling (SinMod) method, which is a good motion estimation method for tagged cardiac magnetic resonance (MR) images, is proposed in this study. The RACE algorithm can automatically, effectively and efficiently produce a very appropriate CF estimate for the SinMod method, under the circumstance that the specified tagging parameters are unknown, on account of the following two key techniques: (1) the well-known mean-shift algorithm, which can provide accurate and rapid CF estimation; and (2) an original two-direction-combination strategy, which can further enhance the accuracy and robustness of CF estimation. Some other available CF estimation algorithms are brought out for comparison. Several validation approaches that can work on the real data without ground truths are specially designed. Experimental results on human body in vivo cardiac data demonstrate the significance of accurate CF estimation for SinMod, and validate the effectiveness of RACE in facilitating the motion estimation performance of SinMod. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Use of thermal imagery for estimation of core body temperature during precooling, exertion, and recovery in wildland firefighter protective clothing.

    PubMed

    Bourlai, Thirimachos; Pryor, Riana R; Suyama, Joe; Reis, Steven E; Hostler, David

    2012-01-01

    Monitoring core body temperature to identify heat stress in first responders and in individuals participating in mass gatherings (e.g., marathons) is difficult. This study utilized high-sensitivity thermal imaging technology to predict the core temperature of human subjects at a distance while performing simulated field operations wearing thermal protective garments. Six male subjects participating in a study of precooling prior to exertion in wildland firefighter thermal protective clothing had thermal images of the face captured with a high-resolution thermal imaging camera concomitant with measures of core and skin temperature before, during, and after treadmill exercise in a heated room. Correlations and measures of agreement between core temperature and thermal imaging-based temperature were performed. The subjects walked an average (± standard deviation) of 42.6 (±5.9) minutes and a distance of 4.2 (±0.6) km on the treadmill. Mean heart rate at the end of exercise was 152 (±33) bpm and core body temperature at the end of exercise was 38.3°C (±0.7°C). A visual relationship and a strong correlation between core temperature and thermal imaging of the face were identified in all subjects, with the closest relationship and best agreement occurring during exercise. The Bland-Altman test of agreement during exercise revealed the majority of measurement pairs to be within two standard deviations of the measured temperature. High-resolution thermal imaging in the middle-wave infrared spectrum (3-5 μm) can be used to accurately estimate core body temperature during exertion in a hot room while participants are wearing wildland firefighting garments. Although this technology is promising, it must be refined. Using alternative measurement sites such as the skin over the carotid artery, using multiple measurement sites, or adding pulse detection may improve the estimation of body temperature by thermal imagery.

  16. Comparative study of the biodegradability of porous silicon films in simulated body fluid.

    PubMed

    Peckham, J; Andrews, G T

    2015-01-01

    The biodegradability of oxidized microporous, mesoporous and macroporous silicon films in a simulated body fluid with ion concentrations similar to those found in human blood plasma were studied using gravimetry. Film dissolution rates were determined by periodically weighing the samples after removal from the fluid. The dissolution rates for microporous silicon were found to be higher than those for mesoporous silicon of comparable porosity. The dissolution rate of macroporous silicon was much lower than that for either microporous or mesoporous silicon. This is attributed to the fact that its specific surface area is much lower than that of microporous and mesoporous silicon. Using an equation adapted from [Surf. Sci. Lett. 306 (1994), L550-L554], the dissolution rate of porous silicon in simulated body fluid can be estimated if the film thickness and specific surface area are known.

  17. Evaluation of human body irradiation caused by radionuclides deposited in the filtration unit of gas mask.

    PubMed

    Cerny, R; Johnova, K; Otahal, P; Thinova, L; Kluson, J

    2017-12-01

    Radioactive aerosol particles represent a serious risk for people facing the consequences of nuclear accident of any kind. The first responders to emergency situation need to be protected by personal protective equipment which includes radiation protection suit supplemented with gas mask. The purpose of this work is to estimate the dose to the organs of responder's body as a result of radionuclide deposition in the filtration unit of the gas mask. The problem was analyzed using Monte Carlo simulations. The dose absorbed by different organs for five representative radionuclides and the dose distribution over the responder's body are presented in this paper. Based on presented MC simulations, we suggest a method of evaluating the irradiation of the responder by the radionuclides deposited in the filtration unit of the gas mask. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Evaluation of Propagation Characteristics Using the Human Body as an Antenna

    PubMed Central

    Li, Jingzhen; Liu, Yuhang; Hao, Yang

    2017-01-01

    In this paper, an inhomogeneous human body model was presented to investigate the propagation characteristics when the human body was used as an antenna to achieve signal transmission. Specifically, the channel gain of four scenarios, namely, (1) both TX electrode and RX electrode were placed in the air, (2) TX electrode was attached on the human body, and RX electrode was placed in the air, (3) TX electrode was placed in the air, and RX electrode was attached on the human body, (4) both the TX electrode and RX electrode were attached on the human body, were studied through numerical simulation in the frequency range 1 MHz to 90 MHz. Furthermore, the comparisons of input efficiency, accepted efficiency, total efficiency, absorption power of human body, and electric field distribution of different distances of four aforementioned scenarios were explored when the frequency was at 44 MHz. In addition, the influences of different human tissues, electrode position, and the distance between electrode and human body on the propagation characteristics were investigated respectively at 44 MHz. The results showed that the channel gain of Scenario 4 was the maximum when the frequency was from 1 MHz to 90 MHz. The propagation characteristics were almost independent of electrode position when the human body was using as an antenna. However, as the distance between TX electrode and human body increased, the channel gain decreased rapidly. The simulations were verified by experimental measurements. The results showed that the simulations were in agreement with the measurements. PMID:29232905

  19. Evaluation of Propagation Characteristics Using the Human Body as an Antenna.

    PubMed

    Li, Jingzhen; Nie, Zedong; Liu, Yuhang; Wang, Lei; Hao, Yang

    2017-12-11

    In this paper, an inhomogeneous human body model was presented to investigate the propagation characteristics when the human body was used as an antenna to achieve signal transmission. Specifically, the channel gain of four scenarios, namely, (1) both TX electrode and RX electrode were placed in the air, (2) TX electrode was attached on the human body, and RX electrode was placed in the air, (3) TX electrode was placed in the air, and RX electrode was attached on the human body, (4) both the TX electrode and RX electrode were attached on the human body, were studied through numerical simulation in the frequency range 1 MHz to 90 MHz. Furthermore, the comparisons of input efficiency, accepted efficiency, total efficiency, absorption power of human body, and electric field distribution of different distances of four aforementioned scenarios were explored when the frequency was at 44 MHz. In addition, the influences of different human tissues, electrode position, and the distance between electrode and human body on the propagation characteristics were investigated respectively at 44 MHz. The results showed that the channel gain of Scenario 4 was the maximum when the frequency was from 1 MHz to 90 MHz. The propagation characteristics were almost independent of electrode position when the human body was using as an antenna. However, as the distance between TX electrode and human body increased, the channel gain decreased rapidly. The simulations were verified by experimental measurements. The results showed that the simulations were in agreement with the measurements.

  20. Scaling of human body composition to stature: new insights into body mass index.

    PubMed

    Heymsfield, Steven B; Gallagher, Dympna; Mayer, Laurel; Beetsch, Joel; Pietrobelli, Angelo

    2007-07-01

    Although Quetelet first reported in 1835 that adult weight scales to the square of stature, limited or no information is available on how anatomical body compartments, including adipose tissue (AT), scale to height. We examined the critical underlying assumptions of adiposity-body mass index (BMI) relations and extended these analyses to major anatomical compartments: skeletal muscle (SM), bone, residual mass, weight (AT+SM+bone), AT-free mass, and organs (liver, brain). This was a cross-sectional analysis of 2 body-composition databases: one including magnetic resonance imaging and dual-energy X-ray absorptiometry (DXA) estimates of evaluated components in adults (total n=411; organs=76) and the other a larger DXA database (n=1346) that included related estimates of fat, fat-free mass, and bone mineral mass. Weight, primary lean components (SM, residual mass, AT-free mass, and fat-free mass), and liver scaled to height with powers of approximately 2 (all P<0.001); bone and bone mineral mass scaled to height with powers >2 (2.31-2.48), and the fraction of weight as bone mineral mass was significantly (P<0.001) correlated with height in women. AT scaled weakly to height with powers of approximately 2, and adiposity was independent of height. Brain mass scaled to height with a power of 0.83 (P=0.04) in men and nonsignificantly in women; the fraction of weight as brain was inversely related to height in women (P=0.002). These observations suggest that short and tall subjects with equivalent BMIs have similar but not identical body composition, provide new insights into earlier BMI-related observations and thus establish a foundation for height-normalized indexes, and create an analytic framework for future studies.

Top