Cost Estimation of Software Development and the Implications for the Program Manager
1992-06-01
Software Lifecycle Model (SLIM), the Jensen System-4 model, the Software Productivity, Quality, and Reliability Estimator ( SPQR \\20), the Constructive...function models in current use are the Software Productivity, Quality, and Reliability Estimator ( SPQR /20) and the Software Architecture Sizing and...Estimator ( SPQR /20) was developed by T. Capers Jones of Software Productivity Research, Inc., in 1985. The model is intended to estimate the outcome
Software For Computing Reliability Of Other Software
NASA Technical Reports Server (NTRS)
Nikora, Allen; Antczak, Thomas M.; Lyu, Michael
1995-01-01
Computer Aided Software Reliability Estimation (CASRE) computer program developed for use in measuring reliability of other software. Easier for non-specialists in reliability to use than many other currently available programs developed for same purpose. CASRE incorporates mathematical modeling capabilities of public-domain Statistical Modeling and Estimation of Reliability Functions for Software (SMERFS) computer program and runs in Windows software environment. Provides menu-driven command interface; enabling and disabling of menu options guides user through (1) selection of set of failure data, (2) execution of mathematical model, and (3) analysis of results from model. Written in C language.
Practical Issues in Implementing Software Reliability Measurement
NASA Technical Reports Server (NTRS)
Nikora, Allen P.; Schneidewind, Norman F.; Everett, William W.; Munson, John C.; Vouk, Mladen A.; Musa, John D.
1999-01-01
Many ways of estimating software systems' reliability, or reliability-related quantities, have been developed over the past several years. Of particular interest are methods that can be used to estimate a software system's fault content prior to test, or to discriminate between components that are fault-prone and those that are not. The results of these methods can be used to: 1) More accurately focus scarce fault identification resources on those portions of a software system most in need of it. 2) Estimate and forecast the risk of exposure to residual faults in a software system during operation, and develop risk and safety criteria to guide the release of a software system to fielded use. 3) Estimate the efficiency of test suites in detecting residual faults. 4) Estimate the stability of the software maintenance process.
Methodology for Software Reliability Prediction. Volume 1.
1987-11-01
SPACECRAFT 0 MANNED SPACECRAFT B ATCH SYSTEM AIRBORNE AVIONICS 0 UNMANNED EVENT C014TROL a REAL TIME CLOSED 0 UNMANNED SPACECRAFT LOOP OPERATINS SPACECRAFT...software reliability. A Software Reliability Measurement Framework was established which spans the life cycle of a software system and includes the...specification, prediction, estimation, and assessment of software reliability. Data from 59 systems , representing over 5 million lines of code, were
NASA Technical Reports Server (NTRS)
Lee, Alice T.; Gunn, Todd; Pham, Tuan; Ricaldi, Ron
1994-01-01
This handbook documents the three software analysis processes the Space Station Software Analysis team uses to assess space station software, including their backgrounds, theories, tools, and analysis procedures. Potential applications of these analysis results are also presented. The first section describes how software complexity analysis provides quantitative information on code, such as code structure and risk areas, throughout the software life cycle. Software complexity analysis allows an analyst to understand the software structure, identify critical software components, assess risk areas within a software system, identify testing deficiencies, and recommend program improvements. Performing this type of analysis during the early design phases of software development can positively affect the process, and may prevent later, much larger, difficulties. The second section describes how software reliability estimation and prediction analysis, or software reliability, provides a quantitative means to measure the probability of failure-free operation of a computer program, and describes the two tools used by JSC to determine failure rates and design tradeoffs between reliability, costs, performance, and schedule.
Estimation and enhancement of real-time software reliability through mutation analysis
NASA Technical Reports Server (NTRS)
Geist, Robert; Offutt, A. J.; Harris, Frederick C., Jr.
1992-01-01
A simulation-based technique for obtaining numerical estimates of the reliability of N-version, real-time software is presented. An extended stochastic Petri net is employed to represent the synchronization structure of N versions of the software, where dependencies among versions are modeled through correlated sampling of module execution times. Test results utilizing specifications for NASA's planetary lander control software indicate that mutation-based testing could hold greater potential for enhancing reliability than the desirable but perhaps unachievable goal of independence among N versions.
NASA Technical Reports Server (NTRS)
Wallace, Dolores R.
2003-01-01
In FY01 we learned that hardware reliability models need substantial changes to account for differences in software, thus making software reliability measurements more effective, accurate, and easier to apply. These reliability models are generally based on familiar distributions or parametric methods. An obvious question is 'What new statistical and probability models can be developed using non-parametric and distribution-free methods instead of the traditional parametric method?" Two approaches to software reliability engineering appear somewhat promising. The first study, begin in FY01, is based in hardware reliability, a very well established science that has many aspects that can be applied to software. This research effort has investigated mathematical aspects of hardware reliability and has identified those applicable to software. Currently the research effort is applying and testing these approaches to software reliability measurement, These parametric models require much project data that may be difficult to apply and interpret. Projects at GSFC are often complex in both technology and schedules. Assessing and estimating reliability of the final system is extremely difficult when various subsystems are tested and completed long before others. Parametric and distribution free techniques may offer a new and accurate way of modeling failure time and other project data to provide earlier and more accurate estimates of system reliability.
NHPP-Based Software Reliability Models Using Equilibrium Distribution
NASA Astrophysics Data System (ADS)
Xiao, Xiao; Okamura, Hiroyuki; Dohi, Tadashi
Non-homogeneous Poisson processes (NHPPs) have gained much popularity in actual software testing phases to estimate the software reliability, the number of remaining faults in software and the software release timing. In this paper, we propose a new modeling approach for the NHPP-based software reliability models (SRMs) to describe the stochastic behavior of software fault-detection processes. The fundamental idea is to apply the equilibrium distribution to the fault-detection time distribution in NHPP-based modeling. We also develop efficient parameter estimation procedures for the proposed NHPP-based SRMs. Through numerical experiments, it can be concluded that the proposed NHPP-based SRMs outperform the existing ones in many data sets from the perspective of goodness-of-fit and prediction performance.
Software reliability perspectives
NASA Technical Reports Server (NTRS)
Wilson, Larry; Shen, Wenhui
1987-01-01
Software which is used in life critical functions must be known to be highly reliable before installation. This requires a strong testing program to estimate the reliability, since neither formal methods, software engineering nor fault tolerant methods can guarantee perfection. Prior to the final testing software goes through a debugging period and many models have been developed to try to estimate reliability from the debugging data. However, the existing models are poorly validated and often give poor performance. This paper emphasizes the fact that part of their failures can be attributed to the random nature of the debugging data given to these models as input, and it poses the problem of correcting this defect as an area of future research.
A study of fault prediction and reliability assessment in the SEL environment
NASA Technical Reports Server (NTRS)
Basili, Victor R.; Patnaik, Debabrata
1986-01-01
An empirical study on estimation and prediction of faults, prediction of fault detection and correction effort, and reliability assessment in the Software Engineering Laboratory environment (SEL) is presented. Fault estimation using empirical relationships and fault prediction using curve fitting method are investigated. Relationships between debugging efforts (fault detection and correction effort) in different test phases are provided, in order to make an early estimate of future debugging effort. This study concludes with the fault analysis, application of a reliability model, and analysis of a normalized metric for reliability assessment and reliability monitoring during development of software.
Developing Confidence Limits For Reliability Of Software
NASA Technical Reports Server (NTRS)
Hayhurst, Kelly J.
1991-01-01
Technique developed for estimating reliability of software by use of Moranda geometric de-eutrophication model. Pivotal method enables straightforward construction of exact bounds with associated degree of statistical confidence about reliability of software. Confidence limits thus derived provide precise means of assessing quality of software. Limits take into account number of bugs found while testing and effects of sampling variation associated with random order of discovering bugs.
An experimental evaluation of software redundancy as a strategy for improving reliability
NASA Technical Reports Server (NTRS)
Eckhardt, Dave E., Jr.; Caglayan, Alper K.; Knight, John C.; Lee, Larry D.; Mcallister, David F.; Vouk, Mladen A.; Kelly, John P. J.
1990-01-01
The strategy of using multiple versions of independently developed software as a means to tolerate residual software design faults is suggested by the success of hardware redundancy for tolerating hardware failures. Although, as generally accepted, the independence of hardware failures resulting from physical wearout can lead to substantial increases in reliability for redundant hardware structures, a similar conclusion is not immediate for software. The degree to which design faults are manifested as independent failures determines the effectiveness of redundancy as a method for improving software reliability. Interest in multi-version software centers on whether it provides an adequate measure of increased reliability to warrant its use in critical applications. The effectiveness of multi-version software is studied by comparing estimates of the failure probabilities of these systems with the failure probabilities of single versions. The estimates are obtained under a model of dependent failures and compared with estimates obtained when failures are assumed to be independent. The experimental results are based on twenty versions of an aerospace application developed and certified by sixty programmers from four universities. Descriptions of the application, development and certification processes, and operational evaluation are given together with an analysis of the twenty versions.
Prediction of Software Reliability using Bio Inspired Soft Computing Techniques.
Diwaker, Chander; Tomar, Pradeep; Poonia, Ramesh C; Singh, Vijander
2018-04-10
A lot of models have been made for predicting software reliability. The reliability models are restricted to using particular types of methodologies and restricted number of parameters. There are a number of techniques and methodologies that may be used for reliability prediction. There is need to focus on parameters consideration while estimating reliability. The reliability of a system may increase or decreases depending on the selection of different parameters used. Thus there is need to identify factors that heavily affecting the reliability of the system. In present days, reusability is mostly used in the various area of research. Reusability is the basis of Component-Based System (CBS). The cost, time and human skill can be saved using Component-Based Software Engineering (CBSE) concepts. CBSE metrics may be used to assess those techniques which are more suitable for estimating system reliability. Soft computing is used for small as well as large-scale problems where it is difficult to find accurate results due to uncertainty or randomness. Several possibilities are available to apply soft computing techniques in medicine related problems. Clinical science of medicine using fuzzy-logic, neural network methodology significantly while basic science of medicine using neural-networks-genetic algorithm most frequently and preferably. There is unavoidable interest shown by medical scientists to use the various soft computing methodologies in genetics, physiology, radiology, cardiology and neurology discipline. CBSE boost users to reuse the past and existing software for making new products to provide quality with a saving of time, memory space, and money. This paper focused on assessment of commonly used soft computing technique like Genetic Algorithm (GA), Neural-Network (NN), Fuzzy Logic, Support Vector Machine (SVM), Ant Colony Optimization (ACO), Particle Swarm Optimization (PSO), and Artificial Bee Colony (ABC). This paper presents working of soft computing techniques and assessment of soft computing techniques to predict reliability. The parameter considered while estimating and prediction of reliability are also discussed. This study can be used in estimation and prediction of the reliability of various instruments used in the medical system, software engineering, computer engineering and mechanical engineering also. These concepts can be applied to both software and hardware, to predict the reliability using CBSE.
Experiments in fault tolerant software reliability
NASA Technical Reports Server (NTRS)
Mcallister, David F.; Tai, K. C.; Vouk, Mladen A.
1987-01-01
The reliability of voting was evaluated in a fault-tolerant software system for small output spaces. The effectiveness of the back-to-back testing process was investigated. Version 3.0 of the RSDIMU-ATS, a semi-automated test bed for certification testing of RSDIMU software, was prepared and distributed. Software reliability estimation methods based on non-random sampling are being studied. The investigation of existing fault-tolerance models was continued and formulation of new models was initiated.
Clayson, Peter E; Miller, Gregory A
2017-01-01
Generalizability theory (G theory) provides a flexible, multifaceted approach to estimating score reliability. G theory's approach to estimating score reliability has important advantages over classical test theory that are relevant for research using event-related brain potentials (ERPs). For example, G theory does not require parallel forms (i.e., equal means, variances, and covariances), can handle unbalanced designs, and provides a single reliability estimate for designs with multiple sources of error. This monograph provides a detailed description of the conceptual framework of G theory using examples relevant to ERP researchers, presents the algorithms needed to estimate ERP score reliability, and provides a detailed walkthrough of newly-developed software, the ERP Reliability Analysis (ERA) Toolbox, that calculates score reliability using G theory. The ERA Toolbox is open-source, Matlab software that uses G theory to estimate the contribution of the number of trials retained for averaging, group, and/or event types on ERP score reliability. The toolbox facilitates the rigorous evaluation of psychometric properties of ERP scores recommended elsewhere in this special issue. Copyright © 2016 Elsevier B.V. All rights reserved.
The Infeasibility of Quantifying the Reliability of Life-Critical Real-Time Software
NASA Technical Reports Server (NTRS)
Butler, Ricky W.; Finelli, George B.
1991-01-01
This paper affirms that the quantification of life-critical software reliability is infeasible using statistical methods whether applied to standard software or fault-tolerant software. The classical methods of estimating reliability are shown to lead to exhorbitant amounts of testing when applied to life-critical software. Reliability growth models are examined and also shown to be incapable of overcoming the need for excessive amounts of testing. The key assumption of software fault tolerance separately programmed versions fail independently is shown to be problematic. This assumption cannot be justified by experimentation in the ultrareliability region and subjective arguments in its favor are not sufficiently strong to justify it as an axiom. Also, the implications of the recent multiversion software experiments support this affirmation.
Hardware and software reliability estimation using simulations
NASA Technical Reports Server (NTRS)
Swern, Frederic L.
1994-01-01
The simulation technique is used to explore the validation of both hardware and software. It was concluded that simulation is a viable means for validating both hardware and software and associating a reliability number with each. This is useful in determining the overall probability of system failure of an embedded processor unit, and improving both the code and the hardware where necessary to meet reliability requirements. The methodologies were proved using some simple programs, and simple hardware models.
Bayesian methods in reliability
NASA Astrophysics Data System (ADS)
Sander, P.; Badoux, R.
1991-11-01
The present proceedings from a course on Bayesian methods in reliability encompasses Bayesian statistical methods and their computational implementation, models for analyzing censored data from nonrepairable systems, the traits of repairable systems and growth models, the use of expert judgment, and a review of the problem of forecasting software reliability. Specific issues addressed include the use of Bayesian methods to estimate the leak rate of a gas pipeline, approximate analyses under great prior uncertainty, reliability estimation techniques, and a nonhomogeneous Poisson process. Also addressed are the calibration sets and seed variables of expert judgment systems for risk assessment, experimental illustrations of the use of expert judgment for reliability testing, and analyses of the predictive quality of software-reliability growth models such as the Weibull order statistics.
Brůžek, Jaroslav; Santos, Frédéric; Dutailly, Bruno; Murail, Pascal; Cunha, Eugenia
2017-10-01
A new tool for skeletal sex estimation based on measurements of the human os coxae is presented using skeletons from a metapopulation of identified adult individuals from twelve independent population samples. For reliable sex estimation, a posterior probability greater than 0.95 was considered to be the classification threshold: below this value, estimates are considered indeterminate. By providing free software, we aim to develop an even more disseminated method for sex estimation. Ten metric variables collected from 2,040 ossa coxa of adult subjects of known sex were recorded between 1986 and 2002 (reference sample). To test both the validity and reliability, a target sample consisting of two series of adult ossa coxa of known sex (n = 623) was used. The DSP2 software (Diagnose Sexuelle Probabiliste v2) is based on Linear Discriminant Analysis, and the posterior probabilities are calculated using an R script. For the reference sample, any combination of four dimensions provides a correct sex estimate in at least 99% of cases. The percentage of individuals for whom sex can be estimated depends on the number of dimensions; for all ten variables it is higher than 90%. Those results are confirmed in the target sample. Our posterior probability threshold of 0.95 for sex estimate corresponds to the traditional sectioning point used in osteological studies. DSP2 software is replacing the former version that should not be used anymore. DSP2 is a robust and reliable technique for sexing adult os coxae, and is also user friendly. © 2017 Wiley Periodicals, Inc.
An experiment in software reliability
NASA Technical Reports Server (NTRS)
Dunham, J. R.; Pierce, J. L.
1986-01-01
The results of a software reliability experiment conducted in a controlled laboratory setting are reported. The experiment was undertaken to gather data on software failures and is one in a series of experiments being pursued by the Fault Tolerant Systems Branch of NASA Langley Research Center to find a means of credibly performing reliability evaluations of flight control software. The experiment tests a small sample of implementations of radar tracking software having ultra-reliability requirements and uses n-version programming for error detection, and repetitive run modeling for failure and fault rate estimation. The experiment results agree with those of Nagel and Skrivan in that the program error rates suggest an approximate log-linear pattern and the individual faults occurred with significantly different error rates. Additional analysis of the experimental data raises new questions concerning the phenomenon of interacting faults. This phenomenon may provide one explanation for software reliability decay.
Integrating Formal Methods and Testing 2002
NASA Technical Reports Server (NTRS)
Cukic, Bojan
2002-01-01
Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.
System and Software Reliability (C103)
NASA Technical Reports Server (NTRS)
Wallace, Dolores
2003-01-01
Within the last decade better reliability models (hardware. software, system) than those currently used have been theorized and developed but not implemented in practice. Previous research on software reliability has shown that while some existing software reliability models are practical, they are no accurate enough. New paradigms of development (e.g. OO) have appeared and associated reliability models have been proposed posed but not investigated. Hardware models have been extensively investigated but not integrated into a system framework. System reliability modeling is the weakest of the three. NASA engineers need better methods and tools to demonstrate that the products meet NASA requirements for reliability measurement. For the new models for the software component of the last decade, there is a great need to bring them into a form that they can be used on software intensive systems. The Statistical Modeling and Estimation of Reliability Functions for Systems (SMERFS'3) tool is an existing vehicle that may be used to incorporate these new modeling advances. Adapting some existing software reliability modeling changes to accommodate major changes in software development technology may also show substantial improvement in prediction accuracy. With some additional research, the next step is to identify and investigate system reliability. System reliability models could then be incorporated in a tool such as SMERFS'3. This tool with better models would greatly add value in assess in GSFC projects.
Corroded Anchor Structure Stability/Reliability (CAS_Stab-R) Software for Hydraulic Structures
2017-12-01
This report describes software that provides a probabilistic estimate of time -to-failure for a corroding anchor strand system. These anchor...stability to the structure. A series of unique pull-test experiments conducted by Ebeling et al. (2016) at the U.S. Army Engineer Research and...Reliability (CAS_Stab-R) produces probabilistic Remaining Anchor Life time estimates for anchor cables based upon the direct corrosion rate for the
NASA Technical Reports Server (NTRS)
Tamayo, Tak Chai
1987-01-01
Quality of software not only is vital to the successful operation of the space station, it is also an important factor in establishing testing requirements, time needed for software verification and integration as well as launching schedules for the space station. Defense of management decisions can be greatly strengthened by combining engineering judgments with statistical analysis. Unlike hardware, software has the characteristics of no wearout and costly redundancies, thus making traditional statistical analysis not suitable in evaluating reliability of software. A statistical model was developed to provide a representation of the number as well as types of failures occur during software testing and verification. From this model, quantitative measure of software reliability based on failure history during testing are derived. Criteria to terminate testing based on reliability objectives and methods to estimate the expected number of fixings required are also presented.
An experiment in software reliability: Additional analyses using data from automated replications
NASA Technical Reports Server (NTRS)
Dunham, Janet R.; Lauterbach, Linda A.
1988-01-01
A study undertaken to collect software error data of laboratory quality for use in the development of credible methods for predicting the reliability of software used in life-critical applications is summarized. The software error data reported were acquired through automated repetitive run testing of three independent implementations of a launch interceptor condition module of a radar tracking problem. The results are based on 100 test applications to accumulate a sufficient sample size for error rate estimation. The data collected is used to confirm the results of two Boeing studies reported in NASA-CR-165836 Software Reliability: Repetitive Run Experimentation and Modeling, and NASA-CR-172378 Software Reliability: Additional Investigations into Modeling With Replicated Experiments, respectively. That is, the results confirm the log-linear pattern of software error rates and reject the hypothesis of equal error rates per individual fault. This rejection casts doubt on the assumption that the program's failure rate is a constant multiple of the number of residual bugs; an assumption which underlies some of the current models of software reliability. data raises new questions concerning the phenomenon of interacting faults.
Development of confidence limits by pivotal functions for estimating software reliability
NASA Technical Reports Server (NTRS)
Dotson, Kelly J.
1987-01-01
The utility of pivotal functions is established for assessing software reliability. Based on the Moranda geometric de-eutrophication model of reliability growth, confidence limits for attained reliability and prediction limits for the time to the next failure are derived using a pivotal function approach. Asymptotic approximations to the confidence and prediction limits are considered and are shown to be inadequate in cases where only a few bugs are found in the software. Departures from the assumed exponentially distributed interfailure times in the model are also investigated. The effect of these departures is discussed relative to restricting the use of the Moranda model.
A Survey of Software Reliability Modeling and Estimation
1983-09-01
considered include: the Jelinski-Moranda Model, the ,Geometric Model,’ and Musa’s Model. A Monte -Carlo study of the behavior of the ’V"’"*least squares...ceedings Number 261, 1979, pp. 34-1, 34-11. IoelAmrit, AGieboSSukert, Alan and Goel, Ararat , "A Guidebookfor Software Reliability Assessment, 1980
Jelicic Kadic, Antonia; Vucic, Katarina; Dosenovic, Svjetlana; Sapunar, Damir; Puljak, Livia
2016-06-01
To compare speed and accuracy of graphical data extraction using manual estimation and open source software. Data points from eligible graphs/figures published in randomized controlled trials (RCTs) from 2009 to 2014 were extracted by two authors independently, both by manual estimation and with the Plot Digitizer, open source software. Corresponding authors of each RCT were contacted up to four times via e-mail to obtain exact numbers that were used to create graphs. Accuracy of each method was compared against the source data from which the original graphs were produced. Software data extraction was significantly faster, reducing time for extraction for 47%. Percent agreement between the two raters was 51% for manual and 53.5% for software data extraction. Percent agreement between the raters and original data was 66% vs. 75% for the first rater and 69% vs. 73% for the second rater, for manual and software extraction, respectively. Data extraction from figures should be conducted using software, whereas manual estimation should be avoided. Using software for data extraction of data presented only in figures is faster and enables higher interrater reliability. Copyright © 2016 Elsevier Inc. All rights reserved.
1988-12-01
software development scene is often charac- c. SPQR Model-Jones terized by: * schedule and cost estimates that are gross-d. COPMO-Thebaut ly inaccurate, SEI...time c. SPQR Model-Jones (in seconds) is simply derived from E by dividing T. Capers Jones has developed a software cost by the Stroud number, S...estimation model called the Software Produc- T=E/S tivity, Quality, and Reliability ( SPQR ) model. The basic approach is similar to that of Boehm’s The value
Lessons learned in deploying software estimation technology and tools
NASA Technical Reports Server (NTRS)
Panlilio-Yap, Nikki; Ho, Danny
1994-01-01
Developing a software product involves estimating various project parameters. This is typically done in the planning stages of the project when there is much uncertainty and very little information. Coming up with accurate estimates of effort, cost, schedule, and reliability is a critical problem faced by all software project managers. The use of estimation models and commercially available tools in conjunction with the best bottom-up estimates of software-development experts enhances the ability of a product development group to derive reasonable estimates of important project parameters. This paper describes the experience of the IBM Software Solutions (SWS) Toronto Laboratory in selecting software estimation models and tools and deploying their use to the laboratory's product development groups. It introduces the SLIM and COSTAR products, the software estimation tools selected for deployment to the product areas, and discusses the rationale for their selection. The paper also describes the mechanisms used for technology injection and tool deployment, and concludes with a discussion of important lessons learned in the technology and tool insertion process.
On Quality and Measures in Software Engineering
ERIC Educational Resources Information Center
Bucur, Ion I.
2006-01-01
Complexity measures are mainly used to estimate vital information about reliability and maintainability of software systems from regular analysis of the source code. Such measures also provide constant feedback during a software project to assist the control of the development procedure. There exist several models to classify a software product's…
NASA Astrophysics Data System (ADS)
Gurov, V. V.
2017-01-01
Software tools for educational purposes, such as e-lessons, computer-based testing system, from the point of view of reliability, have a number of features. The main ones among them are the need to ensure a sufficiently high probability of their faultless operation for a specified time, as well as the impossibility of their rapid recovery by the way of replacing it with a similar running program during the classes. The article considers the peculiarities of reliability evaluation of programs in contrast to assessments of hardware reliability. The basic requirements to reliability of software used for carrying out practical and laboratory classes in the form of computer-based training programs are given. The essential requirements applicable to the reliability of software used for conducting the practical and laboratory studies in the form of computer-based teaching programs are also described. The mathematical tool based on Markov chains, which allows to determine the degree of debugging of the training program for use in the educational process by means of applying the graph of the software modules interaction, is presented.
Software Fault Tolerance: A Tutorial
NASA Technical Reports Server (NTRS)
Torres-Pomales, Wilfredo
2000-01-01
Because of our present inability to produce error-free software, software fault tolerance is and will continue to be an important consideration in software systems. The root cause of software design errors is the complexity of the systems. Compounding the problems in building correct software is the difficulty in assessing the correctness of software for highly complex systems. After a brief overview of the software development processes, we note how hard-to-detect design faults are likely to be introduced during development and how software faults tend to be state-dependent and activated by particular input sequences. Although component reliability is an important quality measure for system level analysis, software reliability is hard to characterize and the use of post-verification reliability estimates remains a controversial issue. For some applications software safety is more important than reliability, and fault tolerance techniques used in those applications are aimed at preventing catastrophes. Single version software fault tolerance techniques discussed include system structuring and closure, atomic actions, inline fault detection, exception handling, and others. Multiversion techniques are based on the assumption that software built differently should fail differently and thus, if one of the redundant versions fails, it is expected that at least one of the other versions will provide an acceptable output. Recovery blocks, N-version programming, and other multiversion techniques are reviewed.
COSTMODL: An automated software development cost estimation tool
NASA Technical Reports Server (NTRS)
Roush, George B.
1991-01-01
The cost of developing computer software continues to consume an increasing portion of many organizations' total budgets, both in the public and private sector. As this trend develops, the capability to produce reliable estimates of the effort and schedule required to develop a candidate software product takes on increasing importance. The COSTMODL program was developed to provide an in-house capability to perform development cost estimates for NASA software projects. COSTMODL is an automated software development cost estimation tool which incorporates five cost estimation algorithms including the latest models for the Ada language and incrementally developed products. The principal characteristic which sets COSTMODL apart from other software cost estimation programs is its capacity to be completely customized to a particular environment. The estimation equations can be recalibrated to reflect the programmer productivity characteristics demonstrated by the user's organization, and the set of significant factors which effect software development costs can be customized to reflect any unique properties of the user's development environment. Careful use of a capability such as COSTMODL can significantly reduce the risk of cost overruns and failed projects.
NASA Software Cost Estimation Model: An Analogy Based Estimation Model
NASA Technical Reports Server (NTRS)
Hihn, Jairus; Juster, Leora; Menzies, Tim; Mathew, George; Johnson, James
2015-01-01
The cost estimation of software development activities is increasingly critical for large scale integrated projects such as those at DOD and NASA especially as the software systems become larger and more complex. As an example MSL (Mars Scientific Laboratory) developed at the Jet Propulsion Laboratory launched with over 2 million lines of code making it the largest robotic spacecraft ever flown (Based on the size of the software). Software development activities are also notorious for their cost growth, with NASA flight software averaging over 50% cost growth. All across the agency, estimators and analysts are increasingly being tasked to develop reliable cost estimates in support of program planning and execution. While there has been extensive work on improving parametric methods there is very little focus on the use of models based on analogy and clustering algorithms. In this paper we summarize our findings on effort/cost model estimation and model development based on ten years of software effort estimation research using data mining and machine learning methods to develop estimation models based on analogy and clustering. The NASA Software Cost Model performance is evaluated by comparing it to COCOMO II, linear regression, and K- nearest neighbor prediction model performance on the same data set.
Software Technology for Adaptable, Reliable Systems (STARS)
1994-03-25
Tmeline(3), SECOMO(3), SEER(3), GSFC Software Engineering Lab Model(l), SLIM(4), SEER-SEM(l), SPQR (2), PRICE-S(2), internally-developed models(3), APMSS(1...3 " Timeline - 3 " SASET (Software Architecture Sizing Estimating Tool) - 2 " MicroMan 11- 2 * LCM (Logistics Cost Model) - 2 * SPQR - 2 * PRICE-S - 2
Markov chains for testing redundant software
NASA Technical Reports Server (NTRS)
White, Allan L.; Sjogren, Jon A.
1988-01-01
A preliminary design for a validation experiment has been developed that addresses several problems unique to assuring the extremely high quality of multiple-version programs in process-control software. The procedure uses Markov chains to model the error states of the multiple version programs. The programs are observed during simulated process-control testing, and estimates are obtained for the transition probabilities between the states of the Markov chain. The experimental Markov chain model is then expanded into a reliability model that takes into account the inertia of the system being controlled. The reliability of the multiple version software is computed from this reliability model at a given confidence level using confidence intervals obtained for the transition probabilities during the experiment. An example demonstrating the method is provided.
A Bayesian modification to the Jelinski-Moranda software reliability growth model
NASA Technical Reports Server (NTRS)
Littlewood, B.; Sofer, A.
1983-01-01
The Jelinski-Moranda (JM) model for software reliability was examined. It is suggested that a major reason for the poor results given by this model is the poor performance of the maximum likelihood method (ML) of parameter estimation. A reparameterization and Bayesian analysis, involving a slight modelling change, are proposed. It is shown that this new Bayesian-Jelinski-Moranda model (BJM) is mathematically quite tractable, and several metrics of interest to practitioners are obtained. The BJM and JM models are compared by using several sets of real software failure data collected and in all cases the BJM model gives superior reliability predictions. A change in the assumption which underlay both models to present the debugging process more accurately is discussed.
Multi-version software reliability through fault-avoidance and fault-tolerance
NASA Technical Reports Server (NTRS)
Vouk, Mladen A.; Mcallister, David F.
1989-01-01
A number of experimental and theoretical issues associated with the practical use of multi-version software to provide run-time tolerance to software faults were investigated. A specialized tool was developed and evaluated for measuring testing coverage for a variety of metrics. The tool was used to collect information on the relationships between software faults and coverage provided by the testing process as measured by different metrics (including data flow metrics). Considerable correlation was found between coverage provided by some higher metrics and the elimination of faults in the code. Back-to-back testing was continued as an efficient mechanism for removal of un-correlated faults, and common-cause faults of variable span. Software reliability estimation methods was also continued based on non-random sampling, and the relationship between software reliability and code coverage provided through testing. New fault tolerance models were formulated. Simulation studies of the Acceptance Voting and Multi-stage Voting algorithms were finished and it was found that these two schemes for software fault tolerance are superior in many respects to some commonly used schemes. Particularly encouraging are the safety properties of the Acceptance testing scheme.
Software reliability through fault-avoidance and fault-tolerance
NASA Technical Reports Server (NTRS)
Vouk, Mladen A.; Mcallister, David F.
1993-01-01
Strategies and tools for the testing, risk assessment and risk control of dependable software-based systems were developed. Part of this project consists of studies to enable the transfer of technology to industry, for example the risk management techniques for safety-concious systems. Theoretical investigations of Boolean and Relational Operator (BRO) testing strategy were conducted for condition-based testing. The Basic Graph Generation and Analysis tool (BGG) was extended to fully incorporate several variants of the BRO metric. Single- and multi-phase risk, coverage and time-based models are being developed to provide additional theoretical and empirical basis for estimation of the reliability and availability of large, highly dependable software. A model for software process and risk management was developed. The use of cause-effect graphing for software specification and validation was investigated. Lastly, advanced software fault-tolerance models were studied to provide alternatives and improvements in situations where simple software fault-tolerance strategies break down.
NASA Technical Reports Server (NTRS)
Simmons, D. B.
1975-01-01
The DOMONIC system has been modified to run on the Univac 1108 and the CDC 6600 as well as the IBM 370 computer system. The DOMONIC monitor system has been implemented to gather data which can be used to optimize the DOMONIC system and to predict the reliability of software developed using DOMONIC. The areas of quality metrics, error characterization, program complexity, program testing, validation and verification are analyzed. A software reliability model for estimating program completion levels and one on which to base system acceptance have been developed. The DAVE system which performs flow analysis and error detection has been converted from the University of Colorado CDC 6400/6600 computer to the IBM 360/370 computer system for use with the DOMONIC system.
NASA Technical Reports Server (NTRS)
Lawrence, Stella
1991-01-01
The object of this project was to develop and calibrate quantitative models for predicting the quality of software. Reliable flight and supporting ground software is a highly important factor in the successful operation of the space shuttle program. The models used in the present study consisted of SMERFS (Statistical Modeling and Estimation of Reliability Functions for Software). There are ten models in SMERFS. For a first run, the results obtained in modeling the cumulative number of failures versus execution time showed fairly good results for our data. Plots of cumulative software failures versus calendar weeks were made and the model results were compared with the historical data on the same graph. If the model agrees with actual historical behavior for a set of data then there is confidence in future predictions for this data. Considering the quality of the data, the models have given some significant results, even at this early stage. With better care in data collection, data analysis, recording of the fixing of failures and CPU execution times, the models should prove extremely helpful in making predictions regarding the future pattern of failures, including an estimate of the number of errors remaining in the software and the additional testing time required for the software quality to reach acceptable levels. It appears that there is no one 'best' model for all cases. It is for this reason that the aim of this project was to test several models. One of the recommendations resulting from this study is that great care must be taken in the collection of data. When using a model, the data should satisfy the model assumptions.
Li, Qiuying; Pham, Hoang
2017-01-01
In this paper, we propose a software reliability model that considers not only error generation but also fault removal efficiency combined with testing coverage information based on a nonhomogeneous Poisson process (NHPP). During the past four decades, many software reliability growth models (SRGMs) based on NHPP have been proposed to estimate the software reliability measures, most of which have the same following agreements: 1) it is a common phenomenon that during the testing phase, the fault detection rate always changes; 2) as a result of imperfect debugging, fault removal has been related to a fault re-introduction rate. But there are few SRGMs in the literature that differentiate between fault detection and fault removal, i.e. they seldom consider the imperfect fault removal efficiency. But in practical software developing process, fault removal efficiency cannot always be perfect, i.e. the failures detected might not be removed completely and the original faults might still exist and new faults might be introduced meanwhile, which is referred to as imperfect debugging phenomenon. In this study, a model aiming to incorporate fault introduction rate, fault removal efficiency and testing coverage into software reliability evaluation is developed, using testing coverage to express the fault detection rate and using fault removal efficiency to consider the fault repair. We compare the performance of the proposed model with several existing NHPP SRGMs using three sets of real failure data based on five criteria. The results exhibit that the model can give a better fitting and predictive performance.
Austin, Peter C
2010-04-22
Multilevel logistic regression models are increasingly being used to analyze clustered data in medical, public health, epidemiological, and educational research. Procedures for estimating the parameters of such models are available in many statistical software packages. There is currently little evidence on the minimum number of clusters necessary to reliably fit multilevel regression models. We conducted a Monte Carlo study to compare the performance of different statistical software procedures for estimating multilevel logistic regression models when the number of clusters was low. We examined procedures available in BUGS, HLM, R, SAS, and Stata. We found that there were qualitative differences in the performance of different software procedures for estimating multilevel logistic models when the number of clusters was low. Among the likelihood-based procedures, estimation methods based on adaptive Gauss-Hermite approximations to the likelihood (glmer in R and xtlogit in Stata) or adaptive Gaussian quadrature (Proc NLMIXED in SAS) tended to have superior performance for estimating variance components when the number of clusters was small, compared to software procedures based on penalized quasi-likelihood. However, only Bayesian estimation with BUGS allowed for accurate estimation of variance components when there were fewer than 10 clusters. For all statistical software procedures, estimation of variance components tended to be poor when there were only five subjects per cluster, regardless of the number of clusters.
Methodology for Software Reliability Prediction. Volume 2.
1987-11-01
The overall acquisition ,z program shall include the resources, schedule, management, structure , and controls necessary to ensure that specified AD...Independent Verification/Validation - Programming Team Structure - Educational Level of Team Members - Experience Level of Team Members * Methods Used...Prediction or Estimation Parameter Supported: Software - Characteristics 3. Objectives: Structured programming studies and Government Ur.’.. procurement
Software Estimation: Developing an Accurate, Reliable Method
2011-08-01
Lake, CA ,93555- 6110 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S...Activity, the systems engineering team is responsible for system and software requirements. 2 . Process Dashboard is a software planning and tracking tool... CA 93555- 6110 760-939-6989 Brad Hodgins is an interim TSP Mentor Coach, SEI-Authorized TSP Coach, SEI-Certified PSP/TSP Instructor, and SEI
Models and metrics for software management and engineering
NASA Technical Reports Server (NTRS)
Basili, V. R.
1988-01-01
This paper attempts to characterize and present a state of the art view of several quantitative models and metrics of the software life cycle. These models and metrics can be used to aid in managing and engineering software projects. They deal with various aspects of the software process and product, including resources allocation and estimation, changes and errors, size, complexity and reliability. Some indication is given of the extent to which the various models have been used and the success they have achieved.
Li, Qiuying; Pham, Hoang
2017-01-01
In this paper, we propose a software reliability model that considers not only error generation but also fault removal efficiency combined with testing coverage information based on a nonhomogeneous Poisson process (NHPP). During the past four decades, many software reliability growth models (SRGMs) based on NHPP have been proposed to estimate the software reliability measures, most of which have the same following agreements: 1) it is a common phenomenon that during the testing phase, the fault detection rate always changes; 2) as a result of imperfect debugging, fault removal has been related to a fault re-introduction rate. But there are few SRGMs in the literature that differentiate between fault detection and fault removal, i.e. they seldom consider the imperfect fault removal efficiency. But in practical software developing process, fault removal efficiency cannot always be perfect, i.e. the failures detected might not be removed completely and the original faults might still exist and new faults might be introduced meanwhile, which is referred to as imperfect debugging phenomenon. In this study, a model aiming to incorporate fault introduction rate, fault removal efficiency and testing coverage into software reliability evaluation is developed, using testing coverage to express the fault detection rate and using fault removal efficiency to consider the fault repair. We compare the performance of the proposed model with several existing NHPP SRGMs using three sets of real failure data based on five criteria. The results exhibit that the model can give a better fitting and predictive performance. PMID:28750091
Statistical modelling of software reliability
NASA Technical Reports Server (NTRS)
Miller, Douglas R.
1991-01-01
During the six-month period from 1 April 1991 to 30 September 1991 the following research papers in statistical modeling of software reliability appeared: (1) A Nonparametric Software Reliability Growth Model; (2) On the Use and the Performance of Software Reliability Growth Models; (3) Research and Development Issues in Software Reliability Engineering; (4) Special Issues on Software; and (5) Software Reliability and Safety.
A measurement system for large, complex software programs
NASA Technical Reports Server (NTRS)
Rone, Kyle Y.; Olson, Kitty M.; Davis, Nathan E.
1994-01-01
This paper describes measurement systems required to forecast, measure, and control activities for large, complex software development and support programs. Initial software cost and quality analysis provides the foundation for meaningful management decisions as a project evolves. In modeling the cost and quality of software systems, the relationship between the functionality, quality, cost, and schedule of the product must be considered. This explicit relationship is dictated by the criticality of the software being developed. This balance between cost and quality is a viable software engineering trade-off throughout the life cycle. Therefore, the ability to accurately estimate the cost and quality of software systems is essential to providing reliable software on time and within budget. Software cost models relate the product error rate to the percent of the project labor that is required for independent verification and validation. The criticality of the software determines which cost model is used to estimate the labor required to develop the software. Software quality models yield an expected error discovery rate based on the software size, criticality, software development environment, and the level of competence of the project and developers with respect to the processes being employed.
A Web-Based System for Bayesian Benchmark Dose Estimation.
Shao, Kan; Shapiro, Andrew J
2018-01-11
Benchmark dose (BMD) modeling is an important step in human health risk assessment and is used as the default approach to identify the point of departure for risk assessment. A probabilistic framework for dose-response assessment has been proposed and advocated by various institutions and organizations; therefore, a reliable tool is needed to provide distributional estimates for BMD and other important quantities in dose-response assessment. We developed an online system for Bayesian BMD (BBMD) estimation and compared results from this software with U.S. Environmental Protection Agency's (EPA's) Benchmark Dose Software (BMDS). The system is built on a Bayesian framework featuring the application of Markov chain Monte Carlo (MCMC) sampling for model parameter estimation and BMD calculation, which makes the BBMD system fundamentally different from the currently prevailing BMD software packages. In addition to estimating the traditional BMDs for dichotomous and continuous data, the developed system is also capable of computing model-averaged BMD estimates. A total of 518 dichotomous and 108 continuous data sets extracted from the U.S. EPA's Integrated Risk Information System (IRIS) database (and similar databases) were used as testing data to compare the estimates from the BBMD and BMDS programs. The results suggest that the BBMD system may outperform the BMDS program in a number of aspects, including fewer failed BMD and BMDL calculations and estimates. The BBMD system is a useful alternative tool for estimating BMD with additional functionalities for BMD analysis based on most recent research. Most importantly, the BBMD has the potential to incorporate prior information to make dose-response modeling more reliable and can provide distributional estimates for important quantities in dose-response assessment, which greatly facilitates the current trend for probabilistic risk assessment. https://doi.org/10.1289/EHP1289.
Terry, Leann; Kelley, Ken
2012-11-01
Composite measures play an important role in psychology and related disciplines. Composite measures almost always have error. Correspondingly, it is important to understand the reliability of the scores from any particular composite measure. However, the point estimates of the reliability of composite measures are fallible and thus all such point estimates should be accompanied by a confidence interval. When confidence intervals are wide, there is much uncertainty in the population value of the reliability coefficient. Given the importance of reporting confidence intervals for estimates of reliability, coupled with the undesirability of wide confidence intervals, we develop methods that allow researchers to plan sample size in order to obtain narrow confidence intervals for population reliability coefficients. We first discuss composite reliability coefficients and then provide a discussion on confidence interval formation for the corresponding population value. Using the accuracy in parameter estimation approach, we develop two methods to obtain accurate estimates of reliability by planning sample size. The first method provides a way to plan sample size so that the expected confidence interval width for the population reliability coefficient is sufficiently narrow. The second method ensures that the confidence interval width will be sufficiently narrow with some desired degree of assurance (e.g., 99% assurance that the 95% confidence interval for the population reliability coefficient will be less than W units wide). The effectiveness of our methods was verified with Monte Carlo simulation studies. We demonstrate how to easily implement the methods with easy-to-use and freely available software. ©2011 The British Psychological Society.
Advanced reliability modeling of fault-tolerant computer-based systems
NASA Technical Reports Server (NTRS)
Bavuso, S. J.
1982-01-01
Two methodologies for the reliability assessment of fault tolerant digital computer based systems are discussed. The computer-aided reliability estimation 3 (CARE 3) and gate logic software simulation (GLOSS) are assessment technologies that were developed to mitigate a serious weakness in the design and evaluation process of ultrareliable digital systems. The weak link is based on the unavailability of a sufficiently powerful modeling technique for comparing the stochastic attributes of one system against others. Some of the more interesting attributes are reliability, system survival, safety, and mission success.
Automatic Certification of Kalman Filters for Reliable Code Generation
NASA Technical Reports Server (NTRS)
Denney, Ewen; Fischer, Bernd; Schumann, Johann; Richardson, Julian
2005-01-01
AUTOFILTER is a tool for automatically deriving Kalman filter code from high-level declarative specifications of state estimation problems. It can generate code with a range of algorithmic characteristics and for several target platforms. The tool has been designed with reliability of the generated code in mind and is able to automatically certify that the code it generates is free from various error classes. Since documentation is an important part of software assurance, AUTOFILTER can also automatically generate various human-readable documents, containing both design and safety related information. We discuss how these features address software assurance standards such as DO-178B.
NASA Technical Reports Server (NTRS)
Gaffney, J. E., Jr.; Judge, R. W.
1981-01-01
A model of a software development process is described. The software development process is seen to consist of a sequence of activities, such as 'program design' and 'module development' (or coding). A manpower estimate is made by multiplying code size by the rates (man months per thousand lines of code) for each of the activities relevant to the particular case of interest and summing up the results. The effect of four objectively determinable factors (organization, software product type, computer type, and code type) on productivity values for each of nine principal software development activities was assessed. Four factors were identified which account for 39% of the observed productivity variation.
Software reliability models for critical applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pham, H.; Pham, M.
This report presents the results of the first phase of the ongoing EG G Idaho, Inc. Software Reliability Research Program. The program is studying the existing software reliability models and proposes a state-of-the-art software reliability model that is relevant to the nuclear reactor control environment. This report consists of three parts: (1) summaries of the literature review of existing software reliability and fault tolerant software reliability models and their related issues, (2) proposed technique for software reliability enhancement, and (3) general discussion and future research. The development of this proposed state-of-the-art software reliability model will be performed in the secondmore » place. 407 refs., 4 figs., 2 tabs.« less
Software reliability models for critical applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pham, H.; Pham, M.
This report presents the results of the first phase of the ongoing EG&G Idaho, Inc. Software Reliability Research Program. The program is studying the existing software reliability models and proposes a state-of-the-art software reliability model that is relevant to the nuclear reactor control environment. This report consists of three parts: (1) summaries of the literature review of existing software reliability and fault tolerant software reliability models and their related issues, (2) proposed technique for software reliability enhancement, and (3) general discussion and future research. The development of this proposed state-of-the-art software reliability model will be performed in the second place.more » 407 refs., 4 figs., 2 tabs.« less
Software reliability models for fault-tolerant avionics computers and related topics
NASA Technical Reports Server (NTRS)
Miller, Douglas R.
1987-01-01
Software reliability research is briefly described. General research topics are reliability growth models, quality of software reliability prediction, the complete monotonicity property of reliability growth, conceptual modelling of software failure behavior, assurance of ultrahigh reliability, and analysis techniques for fault-tolerant systems.
Smith, R P; Dias, J J; Ullah, A; Bhowal, B
2009-05-01
Corrective surgery for Dupuytren's disease represents a significant proportion of a hand surgeon's workload. The decision to go ahead with surgery and the success of surgery requires measuring the degree of contracture of the diseased finger(s). This is performed in clinic with a goniometer, pre- and postoperatively. Monitoring the recurrence of the contracture can inform on surgical outcome, research and audit. We compared visual and computer software-aided estimation of Dupuytren's contractures to clinical goniometric measurements in 60 patients with Dupuytren's disease. Patients' hands were digitally photographed. There were 76 contracted finger joints--70 proximal interphalangeal joints and six distal interphalangeal joints. The degrees of contracture of these images were visually assessed by six orthopaedic staff of differing seniority and re-assessed with computer software. Across assessors, the Pearson correlation between the goniometric measurements and the visual estimations was 0.83 and this significantly improved to 0.88 with computer software. Reliability with intra-class correlations achieved 0.78 and 0.92 for the visual and computer-aided estimations, respectively, and with test-retest analysis, 0.92 for visual estimation and 0.95 for computer-aided measurements. Visual estimations of Dupuytren's contractures correlate well with actual clinical goniometric measurements and improve further if measured with computer software. Digital images permit monitoring of contracture after surgery and may facilitate research into disease progression and auditing of surgical technique.
BurnCase 3D software validation study: Burn size measurement accuracy and inter-rater reliability.
Parvizi, Daryousch; Giretzlehner, Michael; Wurzer, Paul; Klein, Limor Dinur; Shoham, Yaron; Bohanon, Fredrick J; Haller, Herbert L; Tuca, Alexandru; Branski, Ludwik K; Lumenta, David B; Herndon, David N; Kamolz, Lars-P
2016-03-01
The aim of this study was to compare the accuracy of burn size estimation using the computer-assisted software BurnCase 3D (RISC Software GmbH, Hagenberg, Austria) with that using a 2D scan, considered to be the actual burn size. Thirty artificial burn areas were pre planned and prepared on three mannequins (one child, one female, and one male). Five trained physicians (raters) were asked to assess the size of all wound areas using BurnCase 3D software. The results were then compared with the real wound areas, as determined by 2D planimetry imaging. To examine inter-rater reliability, we performed an intraclass correlation analysis with a 95% confidence interval. The mean wound area estimations of the five raters using BurnCase 3D were in total 20.7±0.9% for the child, 27.2±1.5% for the female and 16.5±0.1% for the male mannequin. Our analysis showed relative overestimations of 0.4%, 2.8% and 1.5% for the child, female and male mannequins respectively, compared to the 2D scan. The intraclass correlation between the single raters for mean percentage of the artificial burn areas was 98.6%. There was also a high intraclass correlation between the single raters and the 2D Scan visible. BurnCase 3D is a valid and reliable tool for the determination of total body surface area burned in standard models. Further clinical studies including different pediatric and overweight adult mannequins are warranted. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Archfield, Stacey A.; Steeves, Peter A.; Guthrie, John D.; Ries, Kernell G.
2013-01-01
Streamflow information is critical for addressing any number of hydrologic problems. Often, streamflow information is needed at locations that are ungauged and, therefore, have no observations on which to base water management decisions. Furthermore, there has been increasing need for daily streamflow time series to manage rivers for both human and ecological functions. To facilitate negotiation between human and ecological demands for water, this paper presents the first publicly available, map-based, regional software tool to estimate historical, unregulated, daily streamflow time series (streamflow not affected by human alteration such as dams or water withdrawals) at any user-selected ungauged river location. The map interface allows users to locate and click on a river location, which then links to a spreadsheet-based program that computes estimates of daily streamflow for the river location selected. For a demonstration region in the northeast United States, daily streamflow was, in general, shown to be reliably estimated by the software tool. Estimating the highest and lowest streamflows that occurred in the demonstration region over the period from 1960 through 2004 also was accomplished but with more difficulty and limitations. The software tool provides a general framework that can be applied to other regions for which daily streamflow estimates are needed.
[Research & development on computer expert system for forensic bones estimation].
Zhao, Jun-ji; Zhang, Jan-zheng; Liu, Nin-guo
2005-08-01
To build an expert system for forensic bones estimation. By using the object oriented method, employing statistical data of forensic anthropology, combining the statistical data frame knowledge representation with productions and also using the fuzzy matching and DS evidence theory method. Software for forensic estimation of sex, age and height with opened knowledge base was designed. This system is reliable and effective, and it would be a good assistant of the forensic technician.
Development of a New VLBI Data Analysis Software
NASA Technical Reports Server (NTRS)
Bolotin, Sergei; Gipson, John M.; MacMillan, Daniel S.
2010-01-01
We present an overview of a new VLBI analysis software under development at NASA GSFC. The new software will replace CALC/SOLVE and many related utility programs. It will have the capabilities of the current system as well as incorporate new models and data analysis techniques. In this paper we give a conceptual overview of the new software. We formulate the main goals of the software. The software should be flexible and modular to implement models and estimation techniques that currently exist or will appear in future. On the other hand it should be reliable and possess production quality for processing standard VLBI sessions. Also, it needs to be capable of processing observations from a fully deployed network of VLBI2010 stations in a reasonable time. We describe the software development process and outline the software architecture.
Statistical modeling of software reliability
NASA Technical Reports Server (NTRS)
Miller, Douglas R.
1992-01-01
This working paper discusses the statistical simulation part of a controlled software development experiment being conducted under the direction of the System Validation Methods Branch, Information Systems Division, NASA Langley Research Center. The experiment uses guidance and control software (GCS) aboard a fictitious planetary landing spacecraft: real-time control software operating on a transient mission. Software execution is simulated to study the statistical aspects of reliability and other failure characteristics of the software during development, testing, and random usage. Quantification of software reliability is a major goal. Various reliability concepts are discussed. Experiments are described for performing simulations and collecting appropriate simulated software performance and failure data. This data is then used to make statistical inferences about the quality of the software development and verification processes as well as inferences about the reliability of software versions and reliability growth under random testing and debugging.
Graphical workstation capability for reliability modeling
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Koppen, Sandra V.; Haley, Pamela J.
1992-01-01
In addition to computational capabilities, software tools for estimating the reliability of fault-tolerant digital computer systems must also provide a means of interfacing with the user. Described here is the new graphical interface capability of the hybrid automated reliability predictor (HARP), a software package that implements advanced reliability modeling techniques. The graphics oriented (GO) module provides the user with a graphical language for modeling system failure modes through the selection of various fault-tree gates, including sequence-dependency gates, or by a Markov chain. By using this graphical input language, a fault tree becomes a convenient notation for describing a system. In accounting for any sequence dependencies, HARP converts the fault-tree notation to a complex stochastic process that is reduced to a Markov chain, which it can then solve for system reliability. The graphics capability is available for use on an IBM-compatible PC, a Sun, and a VAX workstation. The GO module is written in the C programming language and uses the graphical kernal system (GKS) standard for graphics implementation. The PC, VAX, and Sun versions of the HARP GO module are currently in beta-testing stages.
Nasendoscopy: an analysis of measurement uncertainties.
Gilleard, Onur; Sommerlad, Brian; Sell, Debbie; Ghanem, Ali; Birch, Malcolm
2013-05-01
Objective : The purpose of this study was to analyze the optical characteristics of two different nasendoscopes used to assess velopharyngeal insufficiency and to quantify the measurement uncertainties that will occur in a typical set of clinical data. Design : The magnification and barrel distortion associated with nasendoscopy was estimated by using computer software to analyze the apparent dimensions of a spatially calibrated test object at varying object-lens distances. In addition, a method of semiquantitative analysis of velopharyngeal closure using nasendoscopy and computer software is described. To calculate the reliability of this method, 10 nasendoscopy examinations were analyzed two times by three separate operators. The measure of intraoperator and interoperator agreement was evaluated using Pearson's r correlation coefficient. Results : Over an object lens distance of 9 mm, magnification caused the visualized dimensions of the test object to increase by 80%. In addition, dimensions of objects visualized in the far-peripheral field of the nasendoscopic examinations appeared approximately 40% smaller than those visualized in the central field. Using computer software to analyze velopharyngeal closure, the mean correlation coefficient for intrarater reliability was .94 and for interrater reliability was .90. Conclusion : Using a custom-designed apparatus, the effect object-lens distance has on the magnification of nasendoscopic images has been quantified. Barrel distortion has also been quantified and was found to be independent of object-lens distance. Using computer software to analyze clinical images, the intraoperator and interoperator correlation appears to show that ratio-metric measurements are reliable.
Warth, Benedikt; Rajkai, György; Mandenius, Carl-Fredrik
2010-05-03
Software sensors for monitoring and on-line estimation of critical bioprocess variables have mainly been used with standard bioreactor sensors, such as electrodes and gas analyzers, where algorithms in the software model have generated the desired state variables. In this article we propose that other on-line instruments, such as NIR probes and on-line HPLC, should be used to make more reliable and flexible software sensors. Five software sensor architectures were compared and evaluated: (1) biomass concentration from an on-line NIR probe, (2) biomass concentration from titrant addition, (3) specific growth rate from titrant addition, (4) specific growth rate from the NIR probe, and (5) specific substrate uptake rate and by-product rate from on-line HPLC and NIR probe signals. The software sensors were demonstrated on an Escherichia coli cultivation expressing a recombinant protein, green fluorescent protein (GFP), but the results could be extrapolated to other production organisms and product proteins. We conclude that well-maintained on-line instrumentation (hardware sensors) can increase the potential of software sensors. This would also strongly support the intentions with process analytical technology and quality-by-design concepts. 2010 Elsevier B.V. All rights reserved.
Van der Elst, Wim; Molenberghs, Geert; Hilgers, Ralf-Dieter; Verbeke, Geert; Heussen, Nicole
2016-11-01
There are various settings in which researchers are interested in the assessment of the correlation between repeated measurements that are taken within the same subject (i.e., reliability). For example, the same rating scale may be used to assess the symptom severity of the same patients by multiple physicians, or the same outcome may be measured repeatedly over time in the same patients. Reliability can be estimated in various ways, for example, using the classical Pearson correlation or the intra-class correlation in clustered data. However, contemporary data often have a complex structure that goes well beyond the restrictive assumptions that are needed with the more conventional methods to estimate reliability. In the current paper, we propose a general and flexible modeling approach that allows for the derivation of reliability estimates, standard errors, and confidence intervals - appropriately taking hierarchies and covariates in the data into account. Our methodology is developed for continuous outcomes together with covariates of an arbitrary type. The methodology is illustrated in a case study, and a Web Appendix is provided which details the computations using the R package CorrMixed and the SAS software. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Understanding software faults and their role in software reliability modeling
NASA Technical Reports Server (NTRS)
Munson, John C.
1994-01-01
This study is a direct result of an on-going project to model the reliability of a large real-time control avionics system. In previous modeling efforts with this system, hardware reliability models were applied in modeling the reliability behavior of this system. In an attempt to enhance the performance of the adapted reliability models, certain software attributes were introduced in these models to control for differences between programs and also sequential executions of the same program. As the basic nature of the software attributes that affect software reliability become better understood in the modeling process, this information begins to have important implications on the software development process. A significant problem arises when raw attribute measures are to be used in statistical models as predictors, for example, of measures of software quality. This is because many of the metrics are highly correlated. Consider the two attributes: lines of code, LOC, and number of program statements, Stmts. In this case, it is quite obvious that a program with a high value of LOC probably will also have a relatively high value of Stmts. In the case of low level languages, such as assembly language programs, there might be a one-to-one relationship between the statement count and the lines of code. When there is a complete absence of linear relationship among the metrics, they are said to be orthogonal or uncorrelated. Usually the lack of orthogonality is not serious enough to affect a statistical analysis. However, for the purposes of some statistical analysis such as multiple regression, the software metrics are so strongly interrelated that the regression results may be ambiguous and possibly even misleading. Typically, it is difficult to estimate the unique effects of individual software metrics in the regression equation. The estimated values of the coefficients are very sensitive to slight changes in the data and to the addition or deletion of variables in the regression equation. Since most of the existing metrics have common elements and are linear combinations of these common elements, it seems reasonable to investigate the structure of the underlying common factors or components that make up the raw metrics. The technique we have chosen to use to explore this structure is a procedure called principal components analysis. Principal components analysis is a decomposition technique that may be used to detect and analyze collinearity in software metrics. When confronted with a large number of metrics measuring a single construct, it may be desirable to represent the set by some smaller number of variables that convey all, or most, of the information in the original set. Principal components are linear transformations of a set of random variables that summarize the information contained in the variables. The transformations are chosen so that the first component accounts for the maximal amount of variation of the measures of any possible linear transform; the second component accounts for the maximal amount of residual variation; and so on. The principal components are constructed so that they represent transformed scores on dimensions that are orthogonal. Through the use of principal components analysis, it is possible to have a set of highly related software attributes mapped into a small number of uncorrelated attribute domains. This definitively solves the problem of multi-collinearity in subsequent regression analysis. There are many software metrics in the literature, but principal component analysis reveals that there are few distinct sources of variation, i.e. dimensions, in this set of metrics. It would appear perfectly reasonable to characterize the measurable attributes of a program with a simple function of a small number of orthogonal metrics each of which represents a distinct software attribute domain.
Development and Evaluation of a Measure of Library Automation.
ERIC Educational Resources Information Center
Pungitore, Verna L.
1986-01-01
Construct validity and reliability estimates indicate that study designed to measure utilization of automation in public and academic libraries was successful in tentatively identifying and measuring three subdimensions of level of automation: quality of hardware, method of software development, and number of automation specialists. Questionnaire…
Kim, Jeong Rye; Shim, Woo Hyun; Yoon, Hee Mang; Hong, Sang Hyup; Lee, Jin Seong; Cho, Young Ah; Kim, Sangki
2017-12-01
The purpose of this study is to evaluate the accuracy and efficiency of a new automatic software system for bone age assessment and to validate its feasibility in clinical practice. A Greulich-Pyle method-based deep-learning technique was used to develop the automatic software system for bone age determination. Using this software, bone age was estimated from left-hand radiographs of 200 patients (3-17 years old) using first-rank bone age (software only), computer-assisted bone age (two radiologists with software assistance), and Greulich-Pyle atlas-assisted bone age (two radiologists with Greulich-Pyle atlas assistance only). The reference bone age was determined by the consensus of two experienced radiologists. First-rank bone ages determined by the automatic software system showed a 69.5% concordance rate and significant correlations with the reference bone age (r = 0.992; p < 0.001). Concordance rates increased with the use of the automatic software system for both reviewer 1 (63.0% for Greulich-Pyle atlas-assisted bone age vs 72.5% for computer-assisted bone age) and reviewer 2 (49.5% for Greulich-Pyle atlas-assisted bone age vs 57.5% for computer-assisted bone age). Reading times were reduced by 18.0% and 40.0% for reviewers 1 and 2, respectively. Automatic software system showed reliably accurate bone age estimations and appeared to enhance efficiency by reducing reading times without compromising the diagnostic accuracy.
NASA Astrophysics Data System (ADS)
Longmore, S. N.; Collins, R. P.; Pfeifer, S.; Fox, S. E.; Mulero-Pazmany, M.; Bezombes, F.; Goodwind, A.; de Juan Ovelar, M.; Knapen, J. H.; Wich, S. A.
2017-02-01
In this paper we describe an unmanned aerial system equipped with a thermal-infrared camera and software pipeline that we have developed to monitor animal populations for conservation purposes. Taking a multi-disciplinary approach to tackle this problem, we use freely available astronomical source detection software and the associated expertise of astronomers, to efficiently and reliably detect humans and animals in aerial thermal-infrared footage. Combining this astronomical detection software with existing machine learning algorithms into a single, automated, end-to-end pipeline, we test the software using aerial video footage taken in a controlled, field-like environment. We demonstrate that the pipeline works reliably and describe how it can be used to estimate the completeness of different observational datasets to objects of a given type as a function of height, observing conditions etc. - a crucial step in converting video footage to scientifically useful information such as the spatial distribution and density of different animal species. Finally, having demonstrated the potential utility of the system, we describe the steps we are taking to adapt the system for work in the field, in particular systematic monitoring of endangered species at National Parks around the world.
Software reliability experiments data analysis and investigation
NASA Technical Reports Server (NTRS)
Walker, J. Leslie; Caglayan, Alper K.
1991-01-01
The objectives are to investigate the fundamental reasons which cause independently developed software programs to fail dependently, and to examine fault tolerant software structures which maximize reliability gain in the presence of such dependent failure behavior. The authors used 20 redundant programs from a software reliability experiment to analyze the software errors causing coincident failures, to compare the reliability of N-version and recovery block structures composed of these programs, and to examine the impact of diversity on software reliability using subpopulations of these programs. The results indicate that both conceptually related and unrelated errors can cause coincident failures and that recovery block structures offer more reliability gain than N-version structures if acceptance checks that fail independently from the software components are available. The authors present a theory of general program checkers that have potential application for acceptance tests.
White, Gary C.; Hines, J.E.
2004-01-01
The reality is that the statistical methods used for analysis of data depend upon the availability of software. Analysis of marked animal data is no different than the rest of the statistical field. The methods used for analysis are those that are available in reliable software packages. Thus, the critical importance of having reliable, up–to–date software available to biologists is obvious. Statisticians have continued to develop more robust models, ever expanding the suite of potential analysis methodsavailable. But without software to implement these newer methods, they will languish in the abstract, and not be applied to the problems deserving them.In the Computers and Software Session, two new software packages are described, a comparison of implementation of methods for the estimation of nest survival is provided, and a more speculative paper about how the next generation of software might be structured is presented.Rotella et al. (2004) compare nest survival estimation with different software packages: SAS logistic regression, SAS non–linear mixed models, and Program MARK. Nests are assumed to be visited at various, possibly infrequent, intervals. All of the approaches described compute nest survival with the same likelihood, and require that the age of the nest is known to account for nests that eventually hatch. However, each approach offers advantages and disadvantages, explored by Rotella et al. (2004).Efford et al. (2004) present a new software package called DENSITY. The package computes population abundance and density from trapping arrays and other detection methods with a new and unique approach. DENSITY represents the first major addition to the analysis of trapping arrays in 20 years.Barker & White (2004) discuss how existing software such as Program MARK require that each new model’s likelihood must be programmed specifically for that model. They wishfully think that future software might allow the user to combine pieces of likelihood functions together to generate estimates. The idea is interesting, and maybe some bright young statistician can work out the specifics to implement the procedure.Choquet et al. (2004) describe MSURGE, a software package that implements the multistate capture–recapture models. The unique feature of MSURGE is that the design matrix is constructed with an interpreted language called GEMACO. Because MSURGE is limited to just multistate models, the special requirements of these likelihoods can be provided.The software and methods presented in these papers gives biologists and wildlife managers an expanding range of possibilities for data analysis. Although ease–of–use is generally getting better, it does not replace the need for understanding of the requirements and structure of the models being computed. The internet provides access to many free software packages as well as user–discussion groups to share knowledge and ideas. (A starting point for wildlife–related applications is (http://www.phidot.org).
2013-01-01
Summary of background data Recent smartphones, such as the iPhone, are often equipped with an accelerometer and magnetometer, which, through software applications, can perform various inclinometric functions. Although these applications are intended for recreational use, they have the potential to measure and quantify range of motion. The purpose of this study was to estimate the intra and inter-rater reliability as well as the criterion validity of the clinometer and compass applications of the iPhone in the assessment cervical range of motion in healthy participants. Methods The sample consisted of 28 healthy participants. Two examiners measured cervical range of motion of each participant twice using the iPhone (for the estimation of intra and inter-reliability) and once with the CROM (for the estimation of criterion validity). Estimates of reliability and validity were then established using the intraclass correlation coefficient (ICC). Results We observed a moderate intra-rater reliability for each movement (ICC = 0.65-0.85) but a poor inter-rater reliability (ICC < 0.60). For the criterion validity, the ICCs are moderate (>0.50) to good (>0.65) for movements of flexion, extension, lateral flexions and right rotation, but poor (<0.50) for the movement left rotation. Conclusion We found good intra-rater reliability and lower inter-rater reliability. When compared to the gold standard, these applications showed moderate to good validity. However, before using the iPhone as an outcome measure in clinical settings, studies should be done on patients presenting with cervical problems. PMID:23829201
Structural reliability methods: Code development status
NASA Astrophysics Data System (ADS)
Millwater, Harry R.; Thacker, Ben H.; Wu, Y.-T.; Cruse, T. A.
1991-05-01
The Probabilistic Structures Analysis Method (PSAM) program integrates state of the art probabilistic algorithms with structural analysis methods in order to quantify the behavior of Space Shuttle Main Engine structures subject to uncertain loadings, boundary conditions, material parameters, and geometric conditions. An advanced, efficient probabilistic structural analysis software program, NESSUS (Numerical Evaluation of Stochastic Structures Under Stress) was developed as a deliverable. NESSUS contains a number of integrated software components to perform probabilistic analysis of complex structures. A nonlinear finite element module NESSUS/FEM is used to model the structure and obtain structural sensitivities. Some of the capabilities of NESSUS/FEM are shown. A Fast Probability Integration module NESSUS/FPI estimates the probability given the structural sensitivities. A driver module, PFEM, couples the FEM and FPI. NESSUS, version 5.0, addresses component reliability, resistance, and risk.
Structural reliability methods: Code development status
NASA Technical Reports Server (NTRS)
Millwater, Harry R.; Thacker, Ben H.; Wu, Y.-T.; Cruse, T. A.
1991-01-01
The Probabilistic Structures Analysis Method (PSAM) program integrates state of the art probabilistic algorithms with structural analysis methods in order to quantify the behavior of Space Shuttle Main Engine structures subject to uncertain loadings, boundary conditions, material parameters, and geometric conditions. An advanced, efficient probabilistic structural analysis software program, NESSUS (Numerical Evaluation of Stochastic Structures Under Stress) was developed as a deliverable. NESSUS contains a number of integrated software components to perform probabilistic analysis of complex structures. A nonlinear finite element module NESSUS/FEM is used to model the structure and obtain structural sensitivities. Some of the capabilities of NESSUS/FEM are shown. A Fast Probability Integration module NESSUS/FPI estimates the probability given the structural sensitivities. A driver module, PFEM, couples the FEM and FPI. NESSUS, version 5.0, addresses component reliability, resistance, and risk.
Early experiences building a software quality prediction model
NASA Technical Reports Server (NTRS)
Agresti, W. W.; Evanco, W. M.; Smith, M. C.
1990-01-01
Early experiences building a software quality prediction model are discussed. The overall research objective is to establish a capability to project a software system's quality from an analysis of its design. The technical approach is to build multivariate models for estimating reliability and maintainability. Data from 21 Ada subsystems were analyzed to test hypotheses about various design structures leading to failure-prone or unmaintainable systems. Current design variables highlight the interconnectivity and visibility of compilation units. Other model variables provide for the effects of reusability and software changes. Reported results are preliminary because additional project data is being obtained and new hypotheses are being developed and tested. Current multivariate regression models are encouraging, explaining 60 to 80 percent of the variation in error density of the subsystems.
Moral-Muñoz, José A; Esteban-Moreno, Bernabé; Arroyo-Morales, Manuel; Cobo, Manuel J; Herrera-Viedma, Enrique
2015-09-01
The objective of this study was to determine the level of agreement between face-to-face hamstring flexibility measurements and free software video analysis in adolescents. Reduced hamstring flexibility is common in adolescents (75% of boys and 35% of girls aged 10). The length of the hamstring muscle has an important role in both the effectiveness and the efficiency of basic human movements, and reduced hamstring flexibility is related to various musculoskeletal conditions. There are various approaches to measuring hamstring flexibility with high reliability; the most commonly used approaches in the scientific literature are the sit-and-reach test, hip joint angle (HJA), and active knee extension. The assessment of hamstring flexibility using video analysis could help with adolescent flexibility follow-up. Fifty-four adolescents from a local school participated in a descriptive study of repeated measures using a crossover design. Active knee extension and HJA were measured with an inclinometer and were simultaneously recorded with a video camera. Each video was downloaded to a computer and subsequently analyzed using Kinovea 0.8.15, a free software application for movement analysis. All outcome measures showed reliability estimates with α > 0.90. The lowest reliability was obtained for HJA (α = 0.91). The preliminary findings support the use of a free software tool for assessing hamstring flexibility, offering health professionals a useful tool for adolescent flexibility follow-up.
Jiang, Yu; Guarino, Peter; Ma, Shuangge; Simon, Steve; Mayo, Matthew S; Raghavan, Rama; Gajewski, Byron J
2016-07-22
Subject recruitment for medical research is challenging. Slow patient accrual leads to increased costs and delays in treatment advances. Researchers need reliable tools to manage and predict the accrual rate. The previously developed Bayesian method integrates researchers' experience on former trials and data from an ongoing study, providing a reliable prediction of accrual rate for clinical studies. In this paper, we present a user-friendly graphical user interface program developed in R. A closed-form solution for the total subjects that can be recruited within a fixed time is derived. We also present a built-in Android system using Java for web browsers and mobile devices. Using the accrual software, we re-evaluated the Veteran Affairs Cooperative Studies Program 558- ROBOTICS study. The application of the software in monitoring and management of recruitment is illustrated for different stages of the trial. This developed accrual software provides a more convenient platform for estimation and prediction of the accrual process.
NASA Technical Reports Server (NTRS)
Lawrence, Stella
1992-01-01
This paper is concerned with methods of measuring and developing quality software. Reliable flight and ground support software is a highly important factor in the successful operation of the space shuttle program. Reliability is probably the most important of the characteristics inherent in the concept of 'software quality'. It is the probability of failure free operation of a computer program for a specified time and environment.
Optimizing Probability of Detection Point Estimate Demonstration
NASA Technical Reports Server (NTRS)
Koshti, Ajay M.
2017-01-01
Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-18231and associated mh18232POD software gives most common methods of POD analysis. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. The paper provides discussion on optimizing probability of detection (POD) demonstration experiments using Point Estimate Method. POD Point estimate method is used by NASA for qualifying special NDE procedures. The point estimate method uses binomial distribution for probability density. Normally, a set of 29 flaws of same size within some tolerance are used in the demonstration. The optimization is performed to provide acceptable value for probability of passing demonstration (PPD) and achieving acceptable value for probability of false (POF) calls while keeping the flaw sizes in the set as small as possible.
A methodology for producing reliable software, volume 1
NASA Technical Reports Server (NTRS)
Stucki, L. G.; Moranda, P. B.; Foshee, G.; Kirchoff, M.; Omre, R.
1976-01-01
An investigation into the areas having an impact on producing reliable software including automated verification tools, software modeling, testing techniques, structured programming, and management techniques is presented. This final report contains the results of this investigation, analysis of each technique, and the definition of a methodology for producing reliable software.
Ionospheric Convection and Structure Using Ground-Based Digital Ionosondes
1988-02-01
M(3000)F2 were provided by the autoscaling software ARTIST which is part of the Digisonde /6, 7/. The virtual height traces scaled from the ionograms...using ARTIST were passed to the true-height analyuis program POLAN /8/, to pro- vide reliable estimates of hmF2. DISCREPANCIES BETWEEN POLAN AND
Analysis of methods of processing of expert information by optimization of administrative decisions
NASA Astrophysics Data System (ADS)
Churakov, D. Y.; Tsarkova, E. G.; Marchenko, N. D.; Grechishnikov, E. V.
2018-03-01
In the real operation the measure definition methodology in case of expert estimation of quality and reliability of application-oriented software products is offered. In operation methods of aggregation of expert estimates on the example of a collective choice of an instrumental control projects in case of software development of a special purpose for needs of institutions are described. Results of operation of dialogue decision making support system are given an algorithm of the decision of the task of a choice on the basis of a method of the analysis of hierarchies and also. The developed algorithm can be applied by development of expert systems to the solution of a wide class of the tasks anyway connected to a multicriteria choice.
System Risk Balancing Profiles: Software Component
NASA Technical Reports Server (NTRS)
Kelly, John C.; Sigal, Burton C.; Gindorf, Tom
2000-01-01
The Software QA / V&V guide will be reviewed and updated based on feedback from NASA organizations and others with a vested interest in this area. Hardware, EEE Parts, Reliability, and Systems Safety are a sample of the future guides that will be developed. Cost Estimates, Lessons Learned, Probability of Failure and PACTS (Prevention, Avoidance, Control or Test) are needed to provide a more complete risk management strategy. This approach to risk management is designed to help balance the resources and program content for risk reduction for NASA's changing environment.
Software Reliability Analysis of NASA Space Flight Software: A Practical Experience
Sukhwani, Harish; Alonso, Javier; Trivedi, Kishor S.; Mcginnis, Issac
2017-01-01
In this paper, we present the software reliability analysis of the flight software of a recently launched space mission. For our analysis, we use the defect reports collected during the flight software development. We find that this software was developed in multiple releases, each release spanning across all software life-cycle phases. We also find that the software releases were developed and tested for four different hardware platforms, spanning from off-the-shelf or emulation hardware to actual flight hardware. For releases that exhibit reliability growth or decay, we fit Software Reliability Growth Models (SRGM); otherwise we fit a distribution function. We find that most releases exhibit reliability growth, with Log-Logistic (NHPP) and S-Shaped (NHPP) as the best-fit SRGMs. For the releases that experience reliability decay, we investigate the causes for the same. We find that such releases were the first software releases to be tested on a new hardware platform, and hence they encountered major hardware integration issues. Also such releases seem to have been developed under time pressure in order to start testing on the new hardware platform sooner. Such releases exhibit poor reliability growth, and hence exhibit high predicted failure rate. Other problems include hardware specification changes and delivery delays from vendors. Thus, our analysis provides critical insights and inputs to the management to improve the software development process. As NASA has moved towards a product line engineering for its flight software development, software for future space missions will be developed in a similar manner and hence the analysis results for this mission can be considered as a baseline for future flight software missions. PMID:29278255
Software Reliability Analysis of NASA Space Flight Software: A Practical Experience.
Sukhwani, Harish; Alonso, Javier; Trivedi, Kishor S; Mcginnis, Issac
2016-01-01
In this paper, we present the software reliability analysis of the flight software of a recently launched space mission. For our analysis, we use the defect reports collected during the flight software development. We find that this software was developed in multiple releases, each release spanning across all software life-cycle phases. We also find that the software releases were developed and tested for four different hardware platforms, spanning from off-the-shelf or emulation hardware to actual flight hardware. For releases that exhibit reliability growth or decay, we fit Software Reliability Growth Models (SRGM); otherwise we fit a distribution function. We find that most releases exhibit reliability growth, with Log-Logistic (NHPP) and S-Shaped (NHPP) as the best-fit SRGMs. For the releases that experience reliability decay, we investigate the causes for the same. We find that such releases were the first software releases to be tested on a new hardware platform, and hence they encountered major hardware integration issues. Also such releases seem to have been developed under time pressure in order to start testing on the new hardware platform sooner. Such releases exhibit poor reliability growth, and hence exhibit high predicted failure rate. Other problems include hardware specification changes and delivery delays from vendors. Thus, our analysis provides critical insights and inputs to the management to improve the software development process. As NASA has moved towards a product line engineering for its flight software development, software for future space missions will be developed in a similar manner and hence the analysis results for this mission can be considered as a baseline for future flight software missions.
Reliability and maintainability assessment factors for reliable fault-tolerant systems
NASA Technical Reports Server (NTRS)
Bavuso, S. J.
1984-01-01
A long term goal of the NASA Langley Research Center is the development of a reliability assessment methodology of sufficient power to enable the credible comparison of the stochastic attributes of one ultrareliable system design against others. This methodology, developed over a 10 year period, is a combined analytic and simulative technique. An analytic component is the Computer Aided Reliability Estimation capability, third generation, or simply CARE III. A simulative component is the Gate Logic Software Simulator capability, or GLOSS. The numerous factors that potentially have a degrading effect on system reliability and the ways in which these factors that are peculiar to highly reliable fault tolerant systems are accounted for in credible reliability assessments. Also presented are the modeling difficulties that result from their inclusion and the ways in which CARE III and GLOSS mitigate the intractability of the heretofore unworkable mathematics.
COSMIC monthly progress report
NASA Technical Reports Server (NTRS)
1994-01-01
Activities of the Computer Software Management and Information Center (COSMIC) are summarized for the month of April 1994. Tables showing the current inventory of programs available from COSMIC are presented and program processing and evaluation activities are summarized. Five articles were prepared for publication in the NASA Tech Brief Journal. These articles (included in this report) describe the following software items: GAP 1.0 - Groove Analysis Program, Version 1.0; SUBTRANS - Subband/Transform MATLAB Functions for Image Processing; CSDM - COLD-SAT Dynamic Model; CASRE - Computer Aided Software Reliability Estimation; and XOPPS - OEL Project Planner/Scheduler Tool. Activities in the areas of marketing, customer service, benefits identification, maintenance and support, and disseminations are also described along with a budget summary.
A new semiquantitative method for evaluation of metastasis progression.
Volarevic, A; Ljujic, B; Volarevic, V; Milovanovic, M; Kanjevac, T; Lukic, A; Arsenijevic, N
2012-01-01
Although recent technical advancements are directed toward developing novel assays and methods for detection of micro and macro metastasis, there are still no reports of reliable, simple to use imaging software that could be used for the detection and quantification of metastasis in tissue sections. We herein report a new semiquantitative method for evaluation of metastasis progression in a well established 4T1 orthotopic mouse model of breast cancer metastasis. The new semiquantitative method presented here was implemented by using the Autodesk AutoCAD 2012 program, a computer-aided design program used primarily for preparing technical drawings in 2 dimensions. By using the Autodesk AutoCAD 2012 software- aided graphical evaluation we managed to detect each metastatic lesion and we precisely calculated the average percentage of lung and liver tissue parenchyma with metastasis in 4T1 tumor-bearing mice. The data were highly specific and relevant to descriptive histological analysis, confirming reliability and accuracy of the AutoCAD 2012 software as new method for quantification of metastatic lesions. The new semiquantitative method using AutoCAD 2012 software provides a novel approach for the estimation of metastatic progression in histological tissue sections.
The Infeasibility of Experimental Quantification of Life-Critical Software Reliability
NASA Technical Reports Server (NTRS)
Butler, Ricky W.; Finelli, George B.
1991-01-01
This paper affirms that quantification of life-critical software reliability is infeasible using statistical methods whether applied to standard software or fault-tolerant software. The key assumption of software fault tolerance|separately programmed versions fail independently|is shown to be problematic. This assumption cannot be justified by experimentation in the ultra-reliability region and subjective arguments in its favor are not sufficiently strong to justify it as an axiom. Also, the implications of the recent multi-version software experiments support this affirmation.
1992-04-01
contractor’s existing data collection, analysis and corrective action system shall be utilized, with modification only as necessary to meet the...either from test or from analysis of field data . The procedures of MIL-STD-756B assume that the reliability of a 18 DEFINE IDENTIFY SOFTWARE LIFE CYCLE...to generate sufficient data to report a statistically valid reliability figure for a class of software. Casual data gathering accumulates data more
Technical Concept Document. Central Archive for Reusable Defense Software (CARDS)
1994-02-28
FeNbry 1994 INFORMAL TECHNICAL REPORT For The SOFTWARE TECHNOLOGY FOR ADAPTABLE, RELIABLE SYSTEMS (STARS) Technical Concept Document Central Archive for...February 1994 INFORMAL TECHNICAL REPORT For The SOFTWARE TECHNOLOGY FOR ADAPTABLE, RELIABLE SYSTEMS (STARS) Technical Concept Document Central Archive...accordance with the DFARS Special Works Clause Developed by: This document, developed under the Software Technology for Adaptable, Reliable Systems
Confirmatory Factor Analysis Alternative: Free, Accessible CBID Software.
Bott, Marjorie; Karanevich, Alex G; Garrard, Lili; Price, Larry R; Mudaranthakam, Dinesh Pal; Gajewski, Byron
2018-02-01
New software that performs Classical and Bayesian Instrument Development (CBID) is reported that seamlessly integrates expert (content validity) and participant data (construct validity) to produce entire reliability estimates with smaller sample requirements. The free CBID software can be accessed through a website and used by clinical investigators in new instrument development. Demonstrations are presented of the three approaches using the CBID software: (a) traditional confirmatory factor analysis (CFA), (b) Bayesian CFA using flat uninformative prior, and (c) Bayesian CFA using content expert data (informative prior). Outcomes of usability testing demonstrate the need to make the user-friendly, free CBID software available to interdisciplinary researchers. CBID has the potential to be a new and expeditious method for instrument development, adding to our current measurement toolbox. This allows for the development of new instruments for measuring determinants of health in smaller diverse populations or populations of rare diseases.
Making statistical inferences about software reliability
NASA Technical Reports Server (NTRS)
Miller, Douglas R.
1988-01-01
Failure times of software undergoing random debugging can be modelled as order statistics of independent but nonidentically distributed exponential random variables. Using this model inferences can be made about current reliability and, if debugging continues, future reliability. This model also shows the difficulty inherent in statistical verification of very highly reliable software such as that used by digital avionics in commercial aircraft.
NASA Technical Reports Server (NTRS)
Dunham, J. R. (Editor); Knight, J. C. (Editor)
1982-01-01
The state of the art in the production of crucial software for flight control applications was addressed. The association between reliability metrics and software is considered. Thirteen software development projects are discussed. A short term need for research in the areas of tool development and software fault tolerance was indicated. For the long term, research in format verification or proof methods was recommended. Formal specification and software reliability modeling, were recommended as topics for both short and long term research.
Survey of Software Assurance Techniques for Highly Reliable Systems
NASA Technical Reports Server (NTRS)
Nelson, Stacy
2004-01-01
This document provides a survey of software assurance techniques for highly reliable systems including a discussion of relevant safety standards for various industries in the United States and Europe, as well as examples of methods used during software development projects. It contains one section for each industry surveyed: Aerospace, Defense, Nuclear Power, Medical Devices and Transportation. Each section provides an overview of applicable standards and examples of a mission or software development project, software assurance techniques used and reliability achieved.
NASA Technical Reports Server (NTRS)
Orr, James K.; Peltier, Daryl
2010-01-01
Thsi slide presentation reviews the avionics software system on board the space shuttle, with particular emphasis on the quality and reliability. The Primary Avionics Software System (PASS) provides automatic and fly-by-wire control of critical shuttle systems which executes in redundant computers. Charts given show the number of space shuttle flights vs time, PASS's development history, and other charts that point to the reliability of the system's development. The reliability of the system is also compared to predicted reliability.
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.
2017-01-01
Today's launch vehicles complex electronic and avionics systems heavily utilize Field Programmable Gate Array (FPGA) integrated circuits (IC) for their superb speed and reconfiguration capabilities. Consequently, FPGAs are prevalent ICs in communication protocols such as MILSTD- 1553B and in control signal commands such as in solenoid valve actuations. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.
An experimental investigation of fault tolerant software structures in an avionics application
NASA Technical Reports Server (NTRS)
Caglayan, Alper K.; Eckhardt, Dave E., Jr.
1989-01-01
The objective of this experimental investigation is to compare the functional performance and software reliability of competing fault tolerant software structures utilizing software diversity. In this experiment, three versions of the redundancy management software for a skewed sensor array have been developed using three diverse failure detection and isolation algorithms and incorporated into various N-version, recovery block and hybrid software structures. The empirical results show that, for maximum functional performance improvement in the selected application domain, the results of diverse algorithms should be voted before being processed by multiple versions without enforced diversity. Results also suggest that when the reliability gain with an N-version structure is modest, recovery block structures are more feasible since higher reliability can be obtained using an acceptance check with a modest reliability.
The Preliminary Results of GMSTech: A Software Development for Microseismic Characterization
NASA Astrophysics Data System (ADS)
Rohaman, Maman; Suhendi, Cahli; Verdhora Ry, Rexha; Sugiartono Prabowo, Billy; Widiyantoro, Sri; Nugraha, Andri Dian; Yudistira, Tedi; Mujihardi, Bambang
2017-04-01
The processing of microseismic data requires reliable software for imaging the condition of subsurface related to occurring microseismicity. In general, the currently available software is only specific for certain processing module and developed by the different developer. However, the software with integrated processing modules will give a better value because the users can use it easier and faster. We developed GMSTech (Ganesha Microseismic Technology), a C# language-based standing-alone software consisting several modules for processing of microseismic data. Its function is to solve a non-linear inverse problem and imaging the subsurface. C# library is supported by ILNumerics to reduce time consumption and give good visualization. In this preliminary result, we will present four developed modules: (1) hypocenter determination, (2) moment magnitude calculation, and (3) 3D seismic tomography. In the first module, we provide four methods for locating the microseismic events that can be chosen by a user independently: simulated annealing method, guided grid-search method, Geiger’s method, and joint hypocenter determination (JHD). The second module can be used for calculating moment magnitude using Brune method and to estimate the released energy of the event. At last, we also provided the module of 3-D seismic tomography for imaging the velocity structures based on delay time tomography. We demonstrated the software using both a synthetic data and a real data from a certain geothermal field in Indonesia. The results for all modules are reliable and remarkable, reviewed statistically by RMS error. We will keep examining the software using another set of data and developing further modules of processing.
Seiger, Rene; Ganger, Sebastian; Kranz, Georg S; Hahn, Andreas; Lanzenberger, Rupert
2018-05-15
Automated cortical thickness (CT) measurements are often used to assess gray matter changes in the healthy and diseased human brain. The FreeSurfer software is frequently applied for this type of analysis. The computational anatomy toolbox (CAT12) for SPM, which offers a fast and easy-to-use alternative approach, was recently made available. In this study, we compared region of interest (ROI)-wise CT estimations of the surface-based FreeSurfer 6 (FS6) software and the volume-based CAT12 toolbox for SPM using 44 elderly healthy female control subjects (HC). In addition, these 44 HCs from the cross-sectional analysis and 34 age- and sex-matched patients with Alzheimer's disease (AD) were used to assess the potential of detecting group differences for each method. Finally, a test-retest analysis was conducted using 19 HC subjects. All data were taken from the OASIS database and MRI scans were recorded at 1.5 Tesla. A strong correlation was observed between both methods in terms of ROI mean CT estimates (R 2 = .83). However, CAT12 delivered significantly higher CT estimations in 32 of the 34 ROIs, indicating a systematic difference between both approaches. Furthermore, both methods were able to reliably detect atrophic brain areas in AD subjects, with the highest decreases in temporal areas. Finally, FS6 as well as CAT12 showed excellent test-retest variability scores. Although CT estimations were systematically higher for CAT12, this study provides evidence that this new toolbox delivers accurate and robust CT estimates and can be considered a fast and reliable alternative to FreeSurfer. © 2018 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.
Reliability of fish size estimates obtained from multibeam imaging sonar
Hightower, Joseph E.; Magowan, Kevin J.; Brown, Lori M.; Fox, Dewayne A.
2013-01-01
Multibeam imaging sonars have considerable potential for use in fisheries surveys because the video-like images are easy to interpret, and they contain information about fish size, shape, and swimming behavior, as well as characteristics of occupied habitats. We examined images obtained using a dual-frequency identification sonar (DIDSON) multibeam sonar for Atlantic sturgeon Acipenser oxyrinchus oxyrinchus, striped bass Morone saxatilis, white perch M. americana, and channel catfish Ictalurus punctatus of known size (20–141 cm) to determine the reliability of length estimates. For ranges up to 11 m, percent measurement error (sonar estimate – total length)/total length × 100 varied by species but was not related to the fish's range or aspect angle (orientation relative to the sonar beam). Least-square mean percent error was significantly different from 0.0 for Atlantic sturgeon (x̄ = −8.34, SE = 2.39) and white perch (x̄ = 14.48, SE = 3.99) but not striped bass (x̄ = 3.71, SE = 2.58) or channel catfish (x̄ = 3.97, SE = 5.16). Underestimating lengths of Atlantic sturgeon may be due to difficulty in detecting the snout or the longer dorsal lobe of the heterocercal tail. White perch was the smallest species tested, and it had the largest percent measurement errors (both positive and negative) and the lowest percentage of images classified as good or acceptable. Automated length estimates for the four species using Echoview software varied with position in the view-field. Estimates tended to be low at more extreme azimuthal angles (fish's angle off-axis within the view-field), but mean and maximum estimates were highly correlated with total length. Software estimates also were biased by fish images partially outside the view-field and when acoustic crosstalk occurred (when a fish perpendicular to the sonar and at relatively close range is detected in the side lobes of adjacent beams). These sources of bias are apparent when files are processed manually and can be filtered out when producing automated software estimates. Multibeam sonar estimates of fish size should be useful for research and management if these potential sources of bias and imprecision are addressed.
Besson, Florent L; Henry, Théophraste; Meyer, Céline; Chevance, Virgile; Roblot, Victoire; Blanchet, Elise; Arnould, Victor; Grimon, Gilles; Chekroun, Malika; Mabille, Laurence; Parent, Florence; Seferian, Andrei; Bulifon, Sophie; Montani, David; Humbert, Marc; Chaumet-Riffaud, Philippe; Lebon, Vincent; Durand, Emmanuel
2018-04-03
Purpose To assess the performance of the ITK-SNAP software for fluorodeoxyglucose (FDG) positron emission tomography (PET) segmentation of complex-shaped lung tumors compared with an optimized, expert-based manual reference standard. Materials and Methods Seventy-six FDG PET images of thoracic lesions were retrospectively segmented by using ITK-SNAP software. Each tumor was manually segmented by six raters to generate an optimized reference standard by using the simultaneous truth and performance level estimate algorithm. Four raters segmented 76 FDG PET images of lung tumors twice by using ITK-SNAP active contour algorithm. Accuracy of ITK-SNAP procedure was assessed by using Dice coefficient and Hausdorff metric. Interrater and intrarater reliability were estimated by using intraclass correlation coefficients of output volumes. Finally, the ITK-SNAP procedure was compared with currently recommended PET tumor delineation methods on the basis of thresholding at 41% volume of interest (VOI; VOI 41 ) and 50% VOI (VOI 50 ) of the tumor's maximal metabolism intensity. Results Accuracy estimates for the ITK-SNAP procedure indicated a Dice coefficient of 0.83 (95% confidence interval: 0.77, 0.89) and a Hausdorff distance of 12.6 mm (95% confidence interval: 9.82, 15.32). Interrater reliability was an intraclass correlation coefficient of 0.94 (95% confidence interval: 0.91, 0.96). The intrarater reliabilities were intraclass correlation coefficients above 0.97. Finally, VOI 41 and VOI 50 accuracy metrics were as follows: Dice coefficient, 0.48 (95% confidence interval: 0.44, 0.51) and 0.34 (95% confidence interval: 0.30, 0.38), respectively, and Hausdorff distance, 25.6 mm (95% confidence interval: 21.7, 31.4) and 31.3 mm (95% confidence interval: 26.8, 38.4), respectively. Conclusion ITK-SNAP is accurate and reliable for active-contour-based segmentation of heterogeneous thoracic PET tumors. ITK-SNAP surpassed the recommended PET methods compared with ground truth manual segmentation. © RSNA, 2018.
NASA Technical Reports Server (NTRS)
Wilson, Larry W.
1989-01-01
The longterm goal of this research is to identify or create a model for use in analyzing the reliability of flight control software. The immediate tasks addressed are the creation of data useful to the study of software reliability and production of results pertinent to software reliability through the analysis of existing reliability models and data. The completed data creation portion of this research consists of a Generic Checkout System (GCS) design document created in cooperation with NASA and Research Triangle Institute (RTI) experimenters. This will lead to design and code reviews with the resulting product being one of the versions used in the Terminal Descent Experiment being conducted by the Systems Validations Methods Branch (SVMB) of NASA/Langley. An appended paper details an investigation of the Jelinski-Moranda and Geometric models for software reliability. The models were given data from a process that they have correctly simulated and asked to make predictions about the reliability of that process. It was found that either model will usually fail to make good predictions. These problems were attributed to randomness in the data and replication of data was recommended.
González, Jorge Ernesto; Radl, Analía; Romero, Ivonne; Barquinero, Joan Francesc; García, Omar; Di Giorgio, Marina
2016-12-01
Mitotic Index (MI) estimation expressed as percentage of mitosis plays an important role as quality control endpoint. To this end, MI is applied to check the lot of media and reagents to be used throughout the assay and also to check cellular viability after blood sample shipping, indicating satisfactory/unsatisfactory conditions for the progression of cell culture. The objective of this paper was to apply the CellProfiler open-source software for automatic detection of mitotic and nuclei figures from digitized images of cultured human lymphocytes for MI assessment, and to compare its performance to that performed through semi-automatic and visual detection. Lymphocytes were irradiated and cultured for mitosis detection. Sets of images from cultures were analyzed visually and findings were compared with those using CellProfiler software. The CellProfiler pipeline includes the detection of nuclei and mitosis with 80% sensitivity and more than 99% specificity. We conclude that CellProfiler is a reliable tool for counting mitosis and nuclei from cytogenetic images, saves considerable time compared to manual operation and reduces the variability derived from the scoring criteria of different scorers. The CellProfiler automated pipeline achieves good agreement with visual counting workflow, i.e. it allows fully automated mitotic and nuclei scoring in cytogenetic images yielding reliable information with minimal user intervention. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Basili, V. R.
1981-01-01
Work on metrics is discussed. Factors that affect software quality are reviewed. Metrics is discussed in terms of criteria achievements, reliability, and fault tolerance. Subjective and objective metrics are distinguished. Product/process and cost/quality metrics are characterized and discussed.
An empirical study of flight control software reliability
NASA Technical Reports Server (NTRS)
Dunham, J. R.; Pierce, J. L.
1986-01-01
The results of a laboratory experiment in flight control software reliability are reported. The experiment tests a small sample of implementations of a pitch axis control law for a PA28 aircraft with over 14 million pitch commands with varying levels of additive input and feedback noise. The testing which uses the method of n-version programming for error detection surfaced four software faults in one implementation of the control law. The small number of detected faults precluded the conduct of the error burst analyses. The pitch axis problem provides data for use in constructing a model in the prediction of the reliability of software in systems with feedback. The study is undertaken to find means to perform reliability evaluations of flight control software.
Nonstationary Extreme Value Analysis in a Changing Climate: A Software Package
NASA Astrophysics Data System (ADS)
Cheng, L.; AghaKouchak, A.; Gilleland, E.
2013-12-01
Numerous studies show that climatic extremes have increased substantially in the second half of the 20th century. For this reason, analysis of extremes under a nonstationary assumption has received a great deal of attention. This paper presents a software package developed for estimation of return levels, return periods, and risks of climatic extremes in a changing climate. This MATLAB software package offers tools for analysis of climate extremes under both stationary and non-stationary assumptions. The Nonstationary Extreme Value Analysis (hereafter, NEVA) provides an efficient and generalized framework for analyzing extremes using Bayesian inference. NEVA estimates the extreme value parameters using a Differential Evolution Markov Chain (DE-MC) which utilizes the genetic algorithm Differential Evolution (DE) for global optimization over the real parameter space with the Markov Chain Monte Carlo (MCMC) approach and has the advantage of simplicity, speed of calculation and convergence over conventional MCMC. NEVA also offers the confidence interval and uncertainty bounds of estimated return levels based on the sampled parameters. NEVA integrates extreme value design concepts, data analysis tools, optimization and visualization, explicitly designed to facilitate analysis extremes in geosciences. The generalized input and output files of this software package make it attractive for users from across different fields. Both stationary and nonstationary components of the package are validated for a number of case studies using empirical return levels. The results show that NEVA reliably describes extremes and their return levels.
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.
2017-01-01
Field Programmable Gate Arrays (FPGAs) integrated circuits (IC) are one of the key electronic components in today's sophisticated launch and space vehicle complex avionic systems, largely due to their superb reprogrammable and reconfigurable capabilities combined with relatively low non-recurring engineering costs (NRE) and short design cycle. Consequently, FPGAs are prevalent ICs in communication protocols and control signal commands. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.
Trends in software reliability for digital flight control
NASA Technical Reports Server (NTRS)
Hecht, H.; Hecht, M.
1983-01-01
Software error data of major recent Digital Flight Control Systems Development Programs. The report summarizes the data, compare these data with similar data from previous surveys and identifies trends and disciplines to improve software reliability.
Software development predictors, error analysis, reliability models and software metric analysis
NASA Technical Reports Server (NTRS)
Basili, Victor
1983-01-01
The use of dynamic characteristics as predictors for software development was studied. It was found that there are some significant factors that could be useful as predictors. From a study on software errors and complexity, it was shown that meaningful results can be obtained which allow insight into software traits and the environment in which it is developed. Reliability models were studied. The research included the field of program testing because the validity of some reliability models depends on the answers to some unanswered questions about testing. In studying software metrics, data collected from seven software engineering laboratory (FORTRAN) projects were examined and three effort reporting accuracy checks were applied to demonstrate the need to validate a data base. Results are discussed.
Sampling design trade-offs in occupancy studies with imperfect detection: examples and software
Bailey, L.L.; Hines, J.E.; Nichols, J.D.
2007-01-01
Researchers have used occupancy, or probability of occupancy, as a response or state variable in a variety of studies (e.g., habitat modeling), and occupancy is increasingly favored by numerous state, federal, and international agencies engaged in monitoring programs. Recent advances in estimation methods have emphasized that reliable inferences can be made from these types of studies if detection and occupancy probabilities are simultaneously estimated. The need for temporal replication at sampled sites to estimate detection probability creates a trade-off between spatial replication (number of sample sites distributed within the area of interest/inference) and temporal replication (number of repeated surveys at each site). Here, we discuss a suite of questions commonly encountered during the design phase of occupancy studies, and we describe software (program GENPRES) developed to allow investigators to easily explore design trade-offs focused on particularities of their study system and sampling limitations. We illustrate the utility of program GENPRES using an amphibian example from Greater Yellowstone National Park, USA.
Software for Tracking Costs of Mars Projects
NASA Technical Reports Server (NTRS)
Wong, Alvin; Warfield, Keith
2003-01-01
The Mars Cost Tracking Model is a computer program that administers a system set up for tracking the costs of future NASA projects that pertain to Mars. Previously, no such tracking system existed, and documentation was written in a variety of formats and scattered in various places. It was difficult to justify costs or even track the history of costs of a spacecraft mission to Mars. The present software enables users to maintain all cost-model definitions, documentation, and justifications of cost estimates in one computer system that is accessible via the Internet. The software provides sign-off safeguards to ensure the reliability of information entered into the system. This system may eventually be used to track the costs of projects other than only those that pertain to Mars.
Maximum Entropy Discrimination Poisson Regression for Software Reliability Modeling.
Chatzis, Sotirios P; Andreou, Andreas S
2015-11-01
Reliably predicting software defects is one of the most significant tasks in software engineering. Two of the major components of modern software reliability modeling approaches are: 1) extraction of salient features for software system representation, based on appropriately designed software metrics and 2) development of intricate regression models for count data, to allow effective software reliability data modeling and prediction. Surprisingly, research in the latter frontier of count data regression modeling has been rather limited. More specifically, a lack of simple and efficient algorithms for posterior computation has made the Bayesian approaches appear unattractive, and thus underdeveloped in the context of software reliability modeling. In this paper, we try to address these issues by introducing a novel Bayesian regression model for count data, based on the concept of max-margin data modeling, effected in the context of a fully Bayesian model treatment with simple and efficient posterior distribution updates. Our novel approach yields a more discriminative learning technique, making more effective use of our training data during model inference. In addition, it allows of better handling uncertainty in the modeled data, which can be a significant problem when the training data are limited. We derive elegant inference algorithms for our model under the mean-field paradigm and exhibit its effectiveness using the publicly available benchmark data sets.
PHM Enabled Autonomous Propellant Loading Operations
NASA Technical Reports Server (NTRS)
Walker, Mark; Figueroa, Fernando
2017-01-01
The utility of Prognostics and Health Management (PHM) software capability applied to Autonomous Operations (AO) remains an active research area within aerospace applications. The ability to gain insight into which assets and subsystems are functioning properly, along with the derivation of confident predictions concerning future ability, reliability, and availability, are important enablers for making sound mission planning decisions. When coupled with software that fully supports mission planning and execution, an integrated solution can be developed that leverages state assessment and estimation for the purposes of delivering autonomous operations. The authors have been applying this integrated, model-based approach to the autonomous loading of cryogenic spacecraft propellants at Kennedy Space Center.
An Extended Kalman Filter-Based Attitude Tracking Algorithm for Star Sensors
Li, Jian; Wei, Xinguo; Zhang, Guangjun
2017-01-01
Efficiency and reliability are key issues when a star sensor operates in tracking mode. In the case of high attitude dynamics, the performance of existing attitude tracking algorithms degenerates rapidly. In this paper an extended Kalman filtering-based attitude tracking algorithm is presented. The star sensor is modeled as a nonlinear stochastic system with the state estimate providing the three degree-of-freedom attitude quaternion and angular velocity. The star positions in the star image are predicted and measured to estimate the optimal attitude. Furthermore, all the cataloged stars observed in the sensor field-of-view according the predicted image motion are accessed using a catalog partition table to speed up the tracking, called star mapping. Software simulation and night-sky experiment are performed to validate the efficiency and reliability of the proposed method. PMID:28825684
An Extended Kalman Filter-Based Attitude Tracking Algorithm for Star Sensors.
Li, Jian; Wei, Xinguo; Zhang, Guangjun
2017-08-21
Efficiency and reliability are key issues when a star sensor operates in tracking mode. In the case of high attitude dynamics, the performance of existing attitude tracking algorithms degenerates rapidly. In this paper an extended Kalman filtering-based attitude tracking algorithm is presented. The star sensor is modeled as a nonlinear stochastic system with the state estimate providing the three degree-of-freedom attitude quaternion and angular velocity. The star positions in the star image are predicted and measured to estimate the optimal attitude. Furthermore, all the cataloged stars observed in the sensor field-of-view according the predicted image motion are accessed using a catalog partition table to speed up the tracking, called star mapping. Software simulation and night-sky experiment are performed to validate the efficiency and reliability of the proposed method.
Age estimation by dentin translucency measurement using digital method: An institutional study
Gupta, Shalini; Chandra, Akhilesh; Agnihotri, Archana; Gupta, Om Prakash; Maurya, Niharika
2017-01-01
Aims: The aims of the present study were to measure translucency on sectioned teeth using available computer hardware and software, to correlate dimensions of root dentin translucency with age, and to assess whether translucency is reliable for age estimation. Materials and Methods: A pilot study was done on 62 freshly extracted single-rooted permanent teeth from 62 different individuals (35 males and 27 females) and their 250 μm thick sections were prepared by micromotor, carborundum disks, and Arkansas stone. Each tooth section was scanned and the images were opened in the Adobe Photoshop software. Measurement of root dentin translucency (TD length) was done on the scanned image by placing two guides (A and B) along the x-axis of ABFO NO. 2 scale. Unpaired t-test, regression analysis, and Pearson correlation coefficient were used as statistical tools. Results: A linear relationship was observed between TD length and age in the regression analysis. The Pearson correlation analysis showed that there was positive correlation (r = 0.52, P = 0.0001) between TD length and age. However, no significant (P > 0.05) difference was observed in the TD length between male (8.44 ± 2.92 mm) and female (7.80 ± 2.79 mm) samples. Conclusion: Translucency of the root dentin increases with age and it can be used as a reliable parameter for the age estimation. The method used here to digitally select and measure translucent root dentin is more refined, better correlated to age, and produce superior age estimation. PMID:28584476
A Model for Assessing the Liability of Seemingly Correct Software
NASA Technical Reports Server (NTRS)
Voas, Jeffrey M.; Voas, Larry K.; Miller, Keith W.
1991-01-01
Current research on software reliability does not lend itself to quantitatively assessing the risk posed by a piece of life-critical software. Black-box software reliability models are too general and make too many assumptions to be applied confidently to assessing the risk of life-critical software. We present a model for assessing the risk caused by a piece of software; this model combines software testing results and Hamlet's probable correctness model. We show how this model can assess software risk for those who insure against a loss that can occur if life-critical software fails.
A study of software standards used in the avionics industry
NASA Technical Reports Server (NTRS)
Hayhurst, Kelly J.
1994-01-01
Within the past decade, software has become an increasingly common element in computing systems. In particular, the role of software used in the aerospace industry, especially in life- or safety-critical applications, is rapidly expanding. This intensifies the need to use effective techniques for achieving and verifying the reliability of avionics software. Although certain software development processes and techniques are mandated by government regulating agencies, no one methodology has been shown to consistently produce reliable software. The knowledge base for designing reliable software simply has not reached the maturity of its hardware counterpart. In an effort to increase our understanding of software, the Langley Research Center conducted a series of experiments over 15 years with the goal of understanding why and how software fails. As part of this program, the effectiveness of current industry standards for the development of avionics is being investigated. This study involves the generation of a controlled environment to conduct scientific experiments on software processes.
Computation of the Molenaar Sijtsma Statistic
NASA Astrophysics Data System (ADS)
Andries van der Ark, L.
The Molenaar Sijtsma statistic is an estimate of the reliability of a test score. In some special cases, computation of the Molenaar Sijtsma statistic requires provisional measures. These provisional measures have not been fully described in the literature, and we show that they have not been implemented in the software. We describe the required provisional measures as to allow the computation of the Molenaar Sijtsma statistic for all data sets.
Regression dilution bias: tools for correction methods and sample size calculation.
Berglund, Lars
2012-08-01
Random errors in measurement of a risk factor will introduce downward bias of an estimated association to a disease or a disease marker. This phenomenon is called regression dilution bias. A bias correction may be made with data from a validity study or a reliability study. In this article we give a non-technical description of designs of reliability studies with emphasis on selection of individuals for a repeated measurement, assumptions of measurement error models, and correction methods for the slope in a simple linear regression model where the dependent variable is a continuous variable. Also, we describe situations where correction for regression dilution bias is not appropriate. The methods are illustrated with the association between insulin sensitivity measured with the euglycaemic insulin clamp technique and fasting insulin, where measurement of the latter variable carries noticeable random error. We provide software tools for estimation of a corrected slope in a simple linear regression model assuming data for a continuous dependent variable and a continuous risk factor from a main study and an additional measurement of the risk factor in a reliability study. Also, we supply programs for estimation of the number of individuals needed in the reliability study and for choice of its design. Our conclusion is that correction for regression dilution bias is seldom applied in epidemiological studies. This may cause important effects of risk factors with large measurement errors to be neglected.
Infusing Reliability Techniques into Software Safety Analysis
NASA Technical Reports Server (NTRS)
Shi, Ying
2015-01-01
Software safety analysis for a large software intensive system is always a challenge. Software safety practitioners need to ensure that software related hazards are completely identified, controlled, and tracked. This paper discusses in detail how to incorporate the traditional reliability techniques into the entire software safety analysis process. In addition, this paper addresses how information can be effectively shared between the various practitioners involved in the software safety analyses. The author has successfully applied the approach to several aerospace applications. Examples are provided to illustrate the key steps of the proposed approach.
Ward, Adam S.; Kelleher, Christa A.; Mason, Seth J. K.; Wagener, Thorsten; McIntyre, Neil; McGlynn, Brian L.; Runkel, Robert L.; Payn, Robert A.
2017-01-01
Researchers and practitioners alike often need to understand and characterize how water and solutes move through a stream in terms of the relative importance of in-stream and near-stream storage and transport processes. In-channel and subsurface storage processes are highly variable in space and time and difficult to measure. Storage estimates are commonly obtained using transient-storage models (TSMs) of the experimentally obtained solute-tracer test data. The TSM equations represent key transport and storage processes with a suite of numerical parameters. Parameter values are estimated via inverse modeling, in which parameter values are iteratively changed until model simulations closely match observed solute-tracer data. Several investigators have shown that TSM parameter estimates can be highly uncertain. When this is the case, parameter values cannot be used reliably to interpret stream-reach functioning. However, authors of most TSM studies do not evaluate or report parameter certainty. Here, we present a software tool linked to the One-dimensional Transport with Inflow and Storage (OTIS) model that enables researchers to conduct uncertainty analyses via Monte-Carlo parameter sampling and to visualize uncertainty and sensitivity results. We demonstrate application of our tool to 2 case studies and compare our results to output obtained from more traditional implementation of the OTIS model. We conclude by suggesting best practices for transient-storage modeling and recommend that future applications of TSMs include assessments of parameter certainty to support comparisons and more reliable interpretations of transport processes.
NASA Astrophysics Data System (ADS)
Tamura, Yoshinobu; Yamada, Shigeru
OSS (open source software) systems which serve as key components of critical infrastructures in our social life are still ever-expanding now. Especially, embedded OSS systems have been gaining a lot of attention in the embedded system area, i.e., Android, BusyBox, TRON, etc. However, the poor handling of quality problem and customer support prohibit the progress of embedded OSS. Also, it is difficult for developers to assess the reliability and portability of embedded OSS on a single-board computer. In this paper, we propose a method of software reliability assessment based on flexible hazard rates for the embedded OSS. Also, we analyze actual data of software failure-occurrence time-intervals to show numerical examples of software reliability assessment for the embedded OSS. Moreover, we compare the proposed hazard rate model for the embedded OSS with the typical conventional hazard rate models by using the comparison criteria of goodness-of-fit. Furthermore, we discuss the optimal software release problem for the porting-phase based on the total expected software maintenance cost.
Singendonk, M M J; Smits, M J; Heijting, I E; van Wijk, M P; Nurko, S; Rosen, R; Weijenborg, P W; Abu-Assi, R; Hoekman, D R; Kuizenga-Wessel, S; Seiboth, G; Benninga, M A; Omari, T I; Kritas, S
2015-02-01
The Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort. Thirty pediatric solid state HRM recordings (13M; mean age 12.1 ± 5.1 years) assessing 10 liquid swallows per patient were analyzed twice by 11 raters (six experts, five non-experts). Software-placed anatomical landmarks required manual adjustment or removal. Integrated relaxation pressure (IRP4s), distal contractile integral (DCI), contractile front velocity (CFV), distal latency (DL) and break size (BS), and an overall CC diagnosis were software-generated. In addition, raters provided their subjective CC diagnosis. Reliability was calculated with Cohen's and Fleiss' kappa (κ) and intraclass correlation coefficient (ICC). Intra- and interrater reliability of software-generated CC diagnosis after manual adjustment of landmarks was substantial (mean κ = 0.69 and 0.77 respectively) and moderate-substantial for subjective CC diagnosis (mean κ = 0.70 and 0.58 respectively). Reliability of both software-generated and subjective diagnosis of normal motility was high (κ = 0.81 and κ = 0.79). Intra- and interrater reliability were excellent for IRP4s, DCI, and BS. Experts had higher interrater reliability than non-experts for DL (ICC = 0.65 vs ICC = 0.36 respectively) and the software-generated diagnosis diffuse esophageal spasm (DES, κ = 0.64 vs κ = 0.30). Among experts, the reliability for the subjective diagnosis of achalasia and esophageal gastric junction outflow obstruction was moderate-substantial (κ = 0.45-0.82). Inter- and intrarater reliability of software-based CC diagnosis of pediatric HRM recordings was high overall. However, experience was a factor influencing the diagnosis of some motility disorders, particularly DES and achalasia. © 2014 John Wiley & Sons Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
... NUCLEAR REGULATORY COMMISSION [NRC-2011-0109] NUREG/CR-XXXX, Development of Quantitative Software..., ``Development of Quantitative Software Reliability Models for Digital Protection Systems of Nuclear Power Plants... of Risk Analysis, Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission...
Reliability Assessment Of Conceptual Launch Vehicles
NASA Technical Reports Server (NTRS)
Bloomer, Lisa A.
2005-01-01
Planning is underway for new NASA missions to the moon and to MARS. These missions carry a great deal of risk, as the Challenger and Columbia accidents demonstrate. In order to minimize the risks to the crew and the mission, risk reduction must be done at every stage, not only in quality manufacturing, but also in design. It is necessary, therefore, to be able to compare the risks posed in different launch vehicle designs. Further, these designs have not yet been implemented, so it is necessary to compare these risks without being able to test the vehicles themselves. This paper will discuss some of the issues involved in this type of comparison. It will start with a general discussion of reliability estimation. It will continue with a short look at some software designed to make this estimation easier and faster. It will conclude with a few recommendations for future tools.
An overview of the mathematical and statistical analysis component of RICIS
NASA Technical Reports Server (NTRS)
Hallum, Cecil R.
1987-01-01
Mathematical and statistical analysis components of RICIS (Research Institute for Computing and Information Systems) can be used in the following problem areas: (1) quantification and measurement of software reliability; (2) assessment of changes in software reliability over time (reliability growth); (3) analysis of software-failure data; and (4) decision logic for whether to continue or stop testing software. Other areas of interest to NASA/JSC where mathematical and statistical analysis can be successfully employed include: math modeling of physical systems, simulation, statistical data reduction, evaluation methods, optimization, algorithm development, and mathematical methods in signal processing.
Modeling reliability measurement of interface on information system: Towards the forensic of rules
NASA Astrophysics Data System (ADS)
Nasution, M. K. M.; Sitompul, Darwin; Harahap, Marwan
2018-02-01
Today almost all machines depend on the software. As a software and hardware system depends also on the rules that are the procedures for its use. If the procedure or program can be reliably characterized by involving the concept of graph, logic, and probability, then regulatory strength can also be measured accordingly. Therefore, this paper initiates an enumeration model to measure the reliability of interfaces based on the case of information systems supported by the rules of use by the relevant agencies. An enumeration model is obtained based on software reliability calculation.
FINDS: A fault inferring nonlinear detection system programmers manual, version 3.0
NASA Technical Reports Server (NTRS)
Lancraft, R. E.
1985-01-01
Detailed software documentation of the digital computer program FINDS (Fault Inferring Nonlinear Detection System) Version 3.0 is provided. FINDS is a highly modular and extensible computer program designed to monitor and detect sensor failures, while at the same time providing reliable state estimates. In this version of the program the FINDS methodology is used to detect, isolate, and compensate for failures in simulated avionics sensors used by the Advanced Transport Operating Systems (ATOPS) Transport System Research Vehicle (TSRV) in a Microwave Landing System (MLS) environment. It is intended that this report serve as a programmers guide to aid in the maintenance, modification, and revision of the FINDS software.
Leveraging Code Comments to Improve Software Reliability
ERIC Educational Resources Information Center
Tan, Lin
2009-01-01
Commenting source code has long been a common practice in software development. This thesis, consisting of three pieces of work, made novel use of the code comments written in natural language to improve software reliability. Our solution combines Natural Language Processing (NLP), Machine Learning, Statistics, and Program Analysis techniques to…
Tilleul, Julien; Querques, Giuseppe; Canoui-Poitrine, Florence; Leveziel, Nicolas; Souied, Eric H
2013-01-01
To assess the ability of the Spectralis optical coherence tomography (OCT) segmentation software to identify the inner limiting membrane and Bruch's membrane in exudative age-related macular degeneration (AMD) patients. Thirty-eight eyes of 38 naive exudative AMD patients were retrospectively included. They all had a complete ophthalmologic examination including Spectralis OCT at baseline, at month 1 and 2. Reliability of the segmentation software was assessed by 2 ophthalmologists. Reliability of the segmentation software was defined as good if both inner limiting membrane and Bruch's membrane were correctly drawn. A total of 38 patients charts were reviewed (114 scans). The inner limiting membrane was correctly drawn by the segmentation software in 114/114 spectral domain OCT scans (100%). Conversely, Bruch's membrane was correctly drawn in 59/114 scans (51.8%). The software was less reliable in locating Bruch's membrane in case of pigment epithelium detachment (PED) than without PED (42.5 vs. 73.5%, respectively; p = 0.049), but its reliability was not associated with SRF or CME (p = 0.55 and p = 0.10, respectively). Segmentation of the inner limiting membrane was constantly trustworthy but Bruch's membrane segmentation was poorly reliable using the automatic Spectralis segmentation software. Based on this software, evaluation of retinal thickness may be incorrect, particularly in case of PED. PED is effectively an important parameter which is not included when measuring retinal thickness. Copyright © 2012 S. Karger AG, Basel.
Software reliability through fault-avoidance and fault-tolerance
NASA Technical Reports Server (NTRS)
Vouk, Mladen A.; Mcallister, David F.
1992-01-01
Accomplishments in the following research areas are summarized: structure based testing, reliability growth, and design testability with risk evaluation; reliability growth models and software risk management; and evaluation of consensus voting, consensus recovery block, and acceptance voting. Four papers generated during the reporting period are included as appendices.
Designing the modern pump: engineering aspects of continuous subcutaneous insulin infusion software.
Welsh, John B; Vargas, Steven; Williams, Gary; Moberg, Sheldon
2010-06-01
Insulin delivery systems attracted the efforts of biological, mechanical, electrical, and software engineers well before they were commercially viable. The introduction of the first commercial insulin pump in 1983 represents an enduring milestone in the history of diabetes management. Since then, pumps have become much more than motorized syringes and have assumed a central role in diabetes management by housing data on insulin delivery and glucose readings, assisting in bolus estimation, and interfacing smoothly with humans and compatible devices. Ensuring the integrity of the embedded software that controls these devices is critical to patient safety and regulatory compliance. As pumps and related devices evolve, software engineers will face challenges and opportunities in designing pumps that are safe, reliable, and feature-rich. The pumps and related systems must also satisfy end users, healthcare providers, and regulatory authorities. In particular, pumps that are combined with glucose sensors and appropriate algorithms will provide the basis for increasingly safe and precise automated insulin delivery-essential steps to developing a fully closed-loop system.
A practical guideline for intracranial volume estimation in patients with Alzheimer's disease
2015-01-01
Background Intracranial volume (ICV) is an important normalization measure used in morphometric analyses to correct for head size in studies of Alzheimer Disease (AD). Inaccurate ICV estimation could introduce bias in the outcome. The current study provides a decision aid in defining protocols for ICV estimation in patients with Alzheimer disease in terms of sampling frequencies that can be optimally used on the volumetric MRI data, and the type of software most suitable for use in estimating the ICV measure. Methods Two groups of 22 subjects are considered, including adult controls (AC) and patients with Alzheimer Disease (AD). Reference measurements were calculated for each subject by manually tracing intracranial cavity by the means of visual inspection. The reliability of reference measurements were assured through intra- and inter- variation analyses. Three publicly well-known software packages (Freesurfer, FSL, and SPM) were examined in their ability to automatically estimate ICV across the groups. Results Analysis of the results supported the significant effect of estimation method, gender, cognitive condition of the subject and the interaction among method and cognitive condition factors in the measured ICV. Results on sub-sampling studies with a 95% confidence showed that in order to keep the accuracy of the interleaved slice sampling protocol above 99%, the sampling period cannot exceed 20 millimeters for AC and 15 millimeters for AD. Freesurfer showed promising estimates for both adult groups. However SPM showed more consistency in its ICV estimation over the different phases of the study. Conclusions This study emphasized the importance in selecting the appropriate protocol, the choice of the sampling period in the manual estimation of ICV and selection of suitable software for the automated estimation of ICV. The current study serves as an initial framework for establishing an appropriate protocol in both manual and automatic ICV estimations with different subject populations. PMID:25953026
Real-time software failure characterization
NASA Technical Reports Server (NTRS)
Dunham, Janet R.; Finelli, George B.
1990-01-01
A series of studies aimed at characterizing the fundamentals of the software failure process has been undertaken as part of a NASA project on the modeling of a real-time aerospace vehicle software reliability. An overview of these studies is provided, and the current study, an investigation of the reliability of aerospace vehicle guidance and control software, is examined. The study approach provides for the collection of life-cycle process data, and for the retention and evaluation of interim software life-cycle products.
Preliminary design of the redundant software experiment
NASA Technical Reports Server (NTRS)
Campbell, Roy; Deimel, Lionel; Eckhardt, Dave, Jr.; Kelly, John; Knight, John; Lauterbach, Linda; Lee, Larry; Mcallister, Dave; Mchugh, John
1985-01-01
The goal of the present experiment is to characterize the fault distributions of highly reliable software replicates, constructed using techniques and environments which are similar to those used in comtemporary industrial software facilities. The fault distributions and their effect on the reliability of fault tolerant configurations of the software will be determined through extensive life testing of the replicates against carefully constructed randomly generated test data. Each detected error will be carefully analyzed to provide insight in to their nature and cause. A direct objective is to develop techniques for reducing the intensity of coincident errors, thus increasing the reliability gain which can be achieved with fault tolerance. Data on the reliability gains realized, and the cost of the fault tolerant configurations can be used to design a companion experiment to determine the cost effectiveness of the fault tolerant strategy. Finally, the data and analysis produced by this experiment will be valuable to the software engineering community as a whole because it will provide a useful insight into the nature and cause of hard to find, subtle faults which escape standard software engineering validation techniques and thus persist far into the software life cycle.
Reliability Engineering for Service Oriented Architectures
2013-02-01
Common Object Request Broker Architecture Ecosystem In software , an ecosystem is a set of applications and/or services that grad- ually build up over time...Enterprise Service Bus Foreign In an SOA context: Any SOA, service or software which the owners of the calling software do not have control of, either...SOA Service Oriented Architecture SRE Software Reliability Engineering System Mode Many systems exhibit different modes of operation. E.g. the cockpit
Chen, Hui; van Eijnatten, Maureen; Wolff, Jan; de Lange, Jan; van der Stelt, Paul F; Lobbezoo, Frank; Aarab, Ghizlane
2017-08-01
The aim of this study was to assess the reliability and accuracy of three different imaging software packages for three-dimensional analysis of the upper airway using CBCT images. To assess the reliability of the software packages, 15 NewTom 5G ® (QR Systems, Verona, Italy) CBCT data sets were randomly and retrospectively selected. Two observers measured the volume, minimum cross-sectional area and the length of the upper airway using Amira ® (Visage Imaging Inc., Carlsbad, CA), 3Diagnosys ® (3diemme, Cantu, Italy) and OnDemand3D ® (CyberMed, Seoul, Republic of Korea) software packages. The intra- and inter-observer reliability of the upper airway measurements were determined using intraclass correlation coefficients and Bland & Altman agreement tests. To assess the accuracy of the software packages, one NewTom 5G ® CBCT data set was used to print a three-dimensional anthropomorphic phantom with known dimensions to be used as the "gold standard". This phantom was subsequently scanned using a NewTom 5G ® scanner. Based on the CBCT data set of the phantom, one observer measured the volume, minimum cross-sectional area, and length of the upper airway using Amira ® , 3Diagnosys ® , and OnDemand3D ® , and compared these measurements with the gold standard. The intra- and inter-observer reliability of the measurements of the upper airway using the different software packages were excellent (intraclass correlation coefficient ≥0.75). There was excellent agreement between all three software packages in volume, minimum cross-sectional area and length measurements. All software packages underestimated the upper airway volume by -8.8% to -12.3%, the minimum cross-sectional area by -6.2% to -14.6%, and the length by -1.6% to -2.9%. All three software packages offered reliable volume, minimum cross-sectional area and length measurements of the upper airway. The length measurements of the upper airway were the most accurate results in all software packages. All software packages underestimated the upper airway dimensions of the anthropomorphic phantom.
NASA Technical Reports Server (NTRS)
Kavi, K. M.
1984-01-01
There have been a number of simulation packages developed for the purpose of designing, testing and validating computer systems, digital systems and software systems. Complex analytical tools based on Markov and semi-Markov processes have been designed to estimate the reliability and performance of simulated systems. Petri nets have received wide acceptance for modeling complex and highly parallel computers. In this research data flow models for computer systems are investigated. Data flow models can be used to simulate both software and hardware in a uniform manner. Data flow simulation techniques provide the computer systems designer with a CAD environment which enables highly parallel complex systems to be defined, evaluated at all levels and finally implemented in either hardware or software. Inherent in data flow concept is the hierarchical handling of complex systems. In this paper we will describe how data flow can be used to model computer system.
Systems Engineering and Integration (SE and I)
NASA Technical Reports Server (NTRS)
Chevers, ED; Haley, Sam
1990-01-01
The issue of technology advancement and future space transportation vehicles is addressed. The challenge is to develop systems which can be evolved and improved in small incremental steps where each increment reduces present cost, improves, reliability, or does neither but sets the stage for a second incremental upgrade that does. Future requirements are interface standards for commercial off the shelf products to aid in the development of integrated facilities; enhanced automated code generation system slightly coupled to specification and design documentation; modeling tools that support data flow analysis; and shared project data bases consisting of technical characteristics cast information, measurement parameters, and reusable software programs. Topics addressed include: advanced avionics development strategy; risk analysis and management; tool quality management; low cost avionics; cost estimation and benefits; computer aided software engineering; computer systems and software safety; system testability; and advanced avionics laboratories - and rapid prototyping. This presentation is represented by viewgraphs only.
Assistant for Specifying Quality Software (ASQS) Mission Area Analysis
1990-12-01
somewhat arbitrary, it was a reasonable and fast approach for partitioning the mission and software domains. The MAD builds on work done by Boeing Aerospace...Reliability ++ Reliability +++ Response 2: NO Discussion: A NO response implies intermittent burns -- most likely to perform attitude control functions...Propulsion Reliability +++ Reliability ++ 4-15 4.8.3 Query BT.3 Query: For intermittent thruster firing requirements, will the average burn time be less than
Reliability and validity of the AutoCAD software method in lumbar lordosis measurement
Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe
2011-01-01
Objective The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Methods Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Results Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. Conclusions AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis. PMID:22654681
Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.
Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe
2011-12-01
The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.
Esposito, Stefano Andrea; Huybrechts, Bart; Slagmolen, Pieter; Cotti, Elisabetta; Coucke, Wim; Pauwels, Ruben; Lambrechts, Paul; Jacobs, Reinhilde
2013-09-01
The routine use of high-resolution images derived from 3-dimensional cone-beam computed tomography (CBCT) datasets enables the linear measurement of lesions in the maxillary and mandibular bones on 3 planes of space. Measurements on different planes would make it possible to obtain real volumetric assessments. In this study, we tested, in vitro, the accuracy and reliability of new dedicated software developed for volumetric lesion assessment in clinical endodontics. Twenty-seven bone defects were created around the apices of 8 teeth in 1 young bovine mandible to simulate periapical lesions of different sizes and shapes. The volume of each defect was determined by taking an impression of the defect using a silicone material. The samples were scanned using an Accuitomo 170 CBCT (J. Morita Mfg Co, Kyoto, Japan), and the data were uploaded into a newly developed dedicated software tool. Two endodontists acted as independent and calibrated observers. They analyzed each bone defect for volume. The difference between the direct volumetric measurements and the measurements obtained with the CBCT images was statistically assessed using a lack-of-fit test. A correlation study was undertaken using the Pearson product-moment correlation coefficient. Intra- and interobserver agreement was also evaluated. The results showed a good fit and strong correlation between both volume measurements (ρ > 0.9) with excellent inter- and intraobserver agreement. Using this software, CBCT proved to be a reliable method in vitro for the estimation of endodontic lesion volumes in bovine jaws. Therefore, it may constitute a new, validated technique for the accurate evaluation and follow-up of apical periodontitis. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Validation of highly reliable, real-time knowledge-based systems
NASA Technical Reports Server (NTRS)
Johnson, Sally C.
1988-01-01
Knowledge-based systems have the potential to greatly increase the capabilities of future aircraft and spacecraft and to significantly reduce support manpower needed for the space station and other space missions. However, a credible validation methodology must be developed before knowledge-based systems can be used for life- or mission-critical applications. Experience with conventional software has shown that the use of good software engineering techniques and static analysis tools can greatly reduce the time needed for testing and simulation of a system. Since exhaustive testing is infeasible, reliability must be built into the software during the design and implementation phases. Unfortunately, many of the software engineering techniques and tools used for conventional software are of little use in the development of knowledge-based systems. Therefore, research at Langley is focused on developing a set of guidelines, methods, and prototype validation tools for building highly reliable, knowledge-based systems. The use of a comprehensive methodology for building highly reliable, knowledge-based systems should significantly decrease the time needed for testing and simulation. A proven record of delivering reliable systems at the beginning of the highly visible testing and simulation phases is crucial to the acceptance of knowledge-based systems in critical applications.
NASA Technical Reports Server (NTRS)
Wilson, Larry
1991-01-01
There are many software reliability models which try to predict future performance of software based on data generated by the debugging process. Unfortunately, the models appear to be unable to account for the random nature of the data. If the same code is debugged multiple times and one of the models is used to make predictions, intolerable variance is observed in the resulting reliability predictions. It is believed that data replication can remove this variance in lab type situations and that it is less than scientific to talk about validating a software reliability model without considering replication. It is also believed that data replication may prove to be cost effective in the real world, thus the research centered on verification of the need for replication and on methodologies for generating replicated data in a cost effective manner. The context of the debugging graph was pursued by simulation and experimentation. Simulation was done for the Basic model and the Log-Poisson model. Reasonable values of the parameters were assigned and used to generate simulated data which is then processed by the models in order to determine limitations on their accuracy. These experiments exploit the existing software and program specimens which are in AIR-LAB to measure the performance of reliability models.
Characterization of fiber diameter using image analysis
NASA Astrophysics Data System (ADS)
Baheti, S.; Tunak, M.
2017-10-01
Due to high surface area and porosity, the applications of nanofibers have increased in recent years. In the production process, determination of average fiber diameter and fiber orientation is crucial for quality assessment. The objective of present study was to compare the relative performance of different methods discussed in literature for estimation of fiber diameter. In this work, the existing automated fiber diameter analysis software packages available in literature were developed and validated based on simulated images of known fiber diameter. Finally, all methods were compared for their reliable and accurate estimation of fiber diameter in electro spun nanofiber membranes based on obtained mean and standard deviation.
Software Quality Assurance Metrics
NASA Technical Reports Server (NTRS)
McRae, Kalindra A.
2004-01-01
Software Quality Assurance (SQA) is a planned and systematic set of activities that ensures conformance of software life cycle processes and products conform to requirements, standards and procedures. In software development, software quality means meeting requirements and a degree of excellence and refinement of a project or product. Software Quality is a set of attributes of a software product by which its quality is described and evaluated. The set of attributes includes functionality, reliability, usability, efficiency, maintainability, and portability. Software Metrics help us understand the technical process that is used to develop a product. The process is measured to improve it and the product is measured to increase quality throughout the life cycle of software. Software Metrics are measurements of the quality of software. Software is measured to indicate the quality of the product, to assess the productivity of the people who produce the product, to assess the benefits derived from new software engineering methods and tools, to form a baseline for estimation, and to help justify requests for new tools or additional training. Any part of the software development can be measured. If Software Metrics are implemented in software development, it can save time, money, and allow the organization to identify the caused of defects which have the greatest effect on software development. The summer of 2004, I worked with Cynthia Calhoun and Frank Robinson in the Software Assurance/Risk Management department. My task was to research and collect, compile, and analyze SQA Metrics that have been used in other projects that are not currently being used by the SA team and report them to the Software Assurance team to see if any metrics can be implemented in their software assurance life cycle process.
Semiautomatic estimation of breast density with DM-Scan software.
Martínez Gómez, I; Casals El Busto, M; Antón Guirao, J; Ruiz Perales, F; Llobet Azpitarte, R
2014-01-01
To evaluate the reproducibility of the calculation of breast density with DM-Scan software, which is based on the semiautomatic segmentation of fibroglandular tissue, and to compare it with the reproducibility of estimation by visual inspection. The study included 655 direct digital mammograms acquired using craniocaudal projections. Three experienced radiologists analyzed the density of the mammograms using DM-Scan, and the inter- and intra-observer agreement between pairs of radiologists for the Boyd and BI-RADS® scales were calculated using the intraclass correlation coefficient. The Kappa index was used to compare the inter- and intra-observer agreements with those obtained previously for visual inspection in the same set of images. For visual inspection, the mean interobserver agreement was 0,876 (95% CI: 0,873-0,879) on the Boyd scale and 0,823 (95% CI: 0,818-0,829) on the BI-RADS® scale. The mean intraobserver agreement was 0,813 (95% CI: 0,796-0,829) on the Boyd scale and 0,770 (95% CI: 0,742-0,797) on the BI-RADS® scale. For DM-Scan, the mean inter- and intra-observer agreement was 0,92, considerably higher than the agreement for visual inspection. The semiautomatic calculation of breast density using DM-Scan software is more reliable and reproducible than visual estimation and reduces the subjectivity and variability in determining breast density. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.
The determination of measures of software reliability
NASA Technical Reports Server (NTRS)
Maxwell, F. D.; Corn, B. C.
1978-01-01
Measurement of software reliability was carried out during the development of data base software for a multi-sensor tracking system. The failure ratio and failure rate were found to be consistent measures. Trend lines could be established from these measurements that provide good visualization of the progress on the job as a whole as well as on individual modules. Over one-half of the observed failures were due to factors associated with the individual run submission rather than with the code proper. Possible application of these findings for line management, project managers, functional management, and regulatory agencies is discussed. Steps for simplifying the measurement process and for use of these data in predicting operational software reliability are outlined.
Meta-analysis of Odds Ratios: Current Good Practices
Chang, Bei-Hung; Hoaglin, David C.
2016-01-01
Background Many systematic reviews of randomized clinical trials lead to meta-analyses of odds ratios. The customary methods of estimating an overall odds ratio involve weighted averages of the individual trials’ estimates of the logarithm of the odds ratio. That approach, however, has several shortcomings, arising from assumptions and approximations, that render the results unreliable. Although the problems have been documented in the literature for many years, the conventional methods persist in software and applications. A well-developed alternative approach avoids the approximations by working directly with the numbers of subjects and events in the arms of the individual trials. Objective We aim to raise awareness of methods that avoid the conventional approximations, can be applied with widely available software, and produce more-reliable results. Methods We summarize the fixed-effect and random-effects approaches to meta-analysis; describe conventional, approximate methods and alternative methods; apply the methods in a meta-analysis of 19 randomized trials of endoscopic sclerotherapy in patients with cirrhosis and esophagogastric varices; and compare the results. We demonstrate the use of SAS, Stata, and R software for the analysis. Results In the example, point estimates and confidence intervals for the overall log-odds-ratio differ between the conventional and alternative methods, in ways that can affect inferences. Programming is straightforward in the three software packages; an appendix gives the details. Conclusions The modest additional programming required should not be an obstacle to adoption of the alternative methods. Because their results are unreliable, use of the conventional methods for meta-analysis of odds ratios should be discontinued. PMID:28169977
NURD: an implementation of a new method to estimate isoform expression from non-uniform RNA-seq data
2013-01-01
Background RNA-Seq technology has been used widely in transcriptome study, and one of the most important applications is to estimate the expression level of genes and their alternative splicing isoforms. There have been several algorithms published to estimate the expression based on different models. Recently Wu et al. published a method that can accurately estimate isoform level expression by considering position-related sequencing biases using nonparametric models. The method has advantages in handling different read distributions, but there hasn’t been an efficient program to implement this algorithm. Results We developed an efficient implementation of the algorithm in the program NURD. It uses a binary interval search algorithm. The program can correct both the global tendency of sequencing bias in the data and local sequencing bias specific to each gene. The correction makes the isoform expression estimation more reliable under various read distributions. And the implementation is computationally efficient in both the memory cost and running time and can be readily scaled up for huge datasets. Conclusion NURD is an efficient and reliable tool for estimating the isoform expression level. Given the reads mapping result and gene annotation file, NURD will output the expression estimation result. The package is freely available for academic use at http://bioinfo.au.tsinghua.edu.cn/software/NURD/. PMID:23837734
Eijgenraam, Susanne M; Boselie, Toon F M; Sieben, Judith M; Bastiaenen, Caroline H G; Willems, Paul C; Arts, Jacobus J; Lataster, Arno
2017-02-01
The amount of vertebral rotation in the axial plane is of key importance in the prognosis and treatment of adolescent idiopathic scoliosis (AIS). Current methods to determine vertebral rotation are either designed for use in analogue plain radiographs and not useful in digital images, or lack measurement precision and are therefore less suitable for the follow-up of rotation in AIS patients. This study aimed to develop a digital X-ray software tool with high measurement precision to determine vertebral rotation in AIS, and to assess its (concurrent) validity and reliability. In this study a combination of basic science and reliability methodology applied in both laboratory and clinical settings was used. Software was developed using the algorithm of the Perdriolle torsion meter for analogue AP plain radiographs of the spine. Software was then assessed for (1) concurrent validity and (2) intra- and interobserver reliability. Plain radiographs of both human cadaver vertebrae and outpatient AIS patients were used. Concurrent validity was measured by two independent observers, both experienced in the assessment of plain radiographs. Reliability-measurements were performed by three independent spine surgeons. Pearson correlation of the software compared with the analogue Perdriolle torsion meter for mid-thoracic vertebrae was 0.98, for low-thoracic vertebrae 0.97 and for lumbar vertebrae 0.97. Measurement exactness of the software was within 5° in 62% of cases and within 10° in 97% of cases. Intraclass correlation coefficient (ICC) for inter-observer reliability was 0.92 (0.91-0.95), ICC for intra-observer reliability was 0.96 (0.94-0.97). We developed a digital X-ray software tool to determine vertebral rotation in AIS with a substantial concurrent validity and reliability, which may be useful for the follow-up of vertebral rotation in AIS patients. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, Brian M.; Ebeida, Mohamed Salah; Eldred, Michael S.
The Dakota (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a exible and extensible interface between simulation codes and iterative analysis methods. Dakota contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quanti cation with sampling, reliability, and stochastic expansion methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components requiredmore » for iterative systems analyses, the Dakota toolkit provides a exible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a user's manual for the Dakota software and provides capability overviews and procedures for software execution, as well as a variety of example studies.« less
Assessment of physical server reliability in multi cloud computing system
NASA Astrophysics Data System (ADS)
Kalyani, B. J. D.; Rao, Kolasani Ramchand H.
2018-04-01
Business organizations nowadays functioning with more than one cloud provider. By spreading cloud deployment across multiple service providers, it creates space for competitive prices that minimize the burden on enterprises spending budget. To assess the software reliability of multi cloud application layered software reliability assessment paradigm is considered with three levels of abstractions application layer, virtualization layer, and server layer. The reliability of each layer is assessed separately and is combined to get the reliability of multi-cloud computing application. In this paper, we focused on how to assess the reliability of server layer with required algorithms and explore the steps in the assessment of server reliability.
NASA Technical Reports Server (NTRS)
Alexandrov, Natalia; Holmes, Bruce J.; Hahn, Andrew S.
2016-01-01
We report on an examination of potential benefits of infusing wireless technologies into various areas of aircraft and airspace operations. The analysis is done in support of a NASA seedling project Efficient Reconfigurable Cockpit Design and Fleet Operations Using Software Intensive, Network Enabled Wireless Architecture (ECON). The study has two objectives. First, we investigate one of the main benefit hypotheses of the ECON proposal: that the replacement of wired technologies with wireless would lead to significant weight reductions on an aircraft, among other benefits. Second, we advance a list of wireless technology applications and discuss their system benefits. With regard to the primary hypothesis, we conclude that the promise of weight reduction is premature. Specificity of the system domain and aircraft, criticality of components, reliability of wireless technologies, the weight of replacement or augmentation equipment, and the cost of infusion must all be taken into account among other considerations, to produce a reliable estimate of weight savings or increase.
NASA Technical Reports Server (NTRS)
1990-01-01
This hardware catalog covers that hardware proposed under the Biomedical Monitoring and Countermeasures Development Program supported by the Johnson Space Center. The hardware items are listed separately by item, and are in alphabetical order. Each hardware item specification consists of four pages. The first page describes background information with an illustration, definition and a history/design status. The second page identifies the general specifications, performance, rack interface requirements, problems, issues, concerns, physical description, and functional description. The level of hardware design reliability is also identified under the maintainability and reliability category. The third page specifies the mechanical design guidelines and assumptions. Described are the material types and weights, modules, and construction methods. Also described is an estimation of percentage of construction which utilizes a particular method, and the percentage of required new mechanical design is documented. The fourth page analyzes the electronics, the scope of design effort, and the software requirements. Electronics are described by percentages of component types and new design. The design effort, as well as, the software requirements are identified and categorized.
A Human Reliability Based Usability Evaluation Method for Safety-Critical Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillippe Palanque; Regina Bernhaupt; Ronald Boring
2006-04-01
Recent years have seen an increasing use of sophisticated interaction techniques including in the field of safety critical interactive software [8]. The use of such techniques has been required in order to increase the bandwidth between the users and systems and thus to help them deal efficiently with increasingly complex systems. These techniques come from research and innovation done in the field of humancomputer interaction (HCI). A significant effort is currently being undertaken by the HCI community in order to apply and extend current usability evaluation techniques to these new kinds of interaction techniques. However, very little has been donemore » to improve the reliability of software offering these kinds of interaction techniques. Even testing basic graphical user interfaces remains a challenge that has rarely been addressed in the field of software engineering [9]. However, the non reliability of interactive software can jeopardize usability evaluation by showing unexpected or undesired behaviors. The aim of this SIG is to provide a forum for both researchers and practitioners interested in testing interactive software. Our goal is to define a roadmap of activities to cross fertilize usability and reliability testing of these kinds of systems to minimize duplicate efforts in both communities.« less
Egger-Danner, C; Schwarzenbacher, H; Willam, A
2014-07-01
The aim of this study was to quantify the impact of genotyping cows with reliable phenotypes for direct health traits on annual monetary genetic gain (AMGG) and discounted profit. The calculations were based on a deterministic approach using ZPLAN software (University of Hohenheim, Stuttgart, Germany). It was assumed that increases in reliability of the total merit index (TMI) of 5, 15, and 25 percentage points were achieved through genotyping 5,000, 25,000, and 50,000 cows, respectively. Costs for phenotyping, genotyping, and genomic estimated breeding values vary between €150 and €20 per cow. The gain in genotyping cows for traits with medium to high heritability is more than for direct health traits with low heritability. The AMGG is increased by 1.5% if the reliability of TMI is 5 percentage points higher (i.e., 5,000 cows genotyped) and 6.53% higher AMGG can be expected when the reliability of TMI is increased by 25 percentage points (i.e., 50,000 cows genotyped). The discounted profit depends not only on the costs of genotyping but also on the population size. This study indicates that genotyping cows with reliable phenotypes is feasible to speed up the availability of genomic estimated breeding values for direct health traits. But, because of the huge amount of valid phenotypes and genotypes needed to establish an efficient genomic evaluation, it is likely that financial constraints will be the main limiting factor for implementation into breeding program such as Fleckvieh Austria. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Software reliability: Application of a reliability model to requirements error analysis
NASA Technical Reports Server (NTRS)
Logan, J.
1980-01-01
The application of a software reliability model having a well defined correspondence of computer program properties to requirements error analysis is described. Requirements error categories which can be related to program structural elements are identified and their effect on program execution considered. The model is applied to a hypothetical B-5 requirement specification for a program module.
Predicting Software Suitability Using a Bayesian Belief Network
NASA Technical Reports Server (NTRS)
Beaver, Justin M.; Schiavone, Guy A.; Berrios, Joseph S.
2005-01-01
The ability to reliably predict the end quality of software under development presents a significant advantage for a development team. It provides an opportunity to address high risk components earlier in the development life cycle, when their impact is minimized. This research proposes a model that captures the evolution of the quality of a software product, and provides reliable forecasts of the end quality of the software being developed in terms of product suitability. Development team skill, software process maturity, and software problem complexity are hypothesized as driving factors of software product quality. The cause-effect relationships between these factors and the elements of software suitability are modeled using Bayesian Belief Networks, a machine learning method. This research presents a Bayesian Network for software quality, and the techniques used to quantify the factors that influence and represent software quality. The developed model is found to be effective in predicting the end product quality of small-scale software development efforts.
Gmyr, Valery; Bonner, Caroline; Lukowiak, Bruno; Pawlowski, Valerie; Dellaleau, Nathalie; Belaich, Sandrine; Aluka, Isanga; Moermann, Ericka; Thevenet, Julien; Ezzouaoui, Rimed; Queniat, Gurvan; Pattou, Francois; Kerr-Conte, Julie
2015-01-01
Reliable assessment of islet viability, mass, and purity must be met prior to transplanting an islet preparation into patients with type 1 diabetes. The standard method for quantifying human islet preparations is by direct microscopic analysis of dithizone-stained islet samples, but this technique may be susceptible to inter-/intraobserver variability, which may induce false positive/negative islet counts. Here we describe a simple, reliable, automated digital image analysis (ADIA) technique for accurately quantifying islets into total islet number, islet equivalent number (IEQ), and islet purity before islet transplantation. Islets were isolated and purified from n = 42 human pancreata according to the automated method of Ricordi et al. For each preparation, three islet samples were stained with dithizone and expressed as IEQ number. Islets were analyzed manually by microscopy or automatically quantified using Nikon's inverted Eclipse Ti microscope with built-in NIS-Elements Advanced Research (AR) software. The AIDA method significantly enhanced the number of islet preparations eligible for engraftment compared to the standard manual method (p < 0.001). Comparisons of individual methods showed good correlations between mean values of IEQ number (r(2) = 0.91) and total islet number (r(2) = 0.88) and thus increased to r(2) = 0.93 when islet surface area was estimated comparatively with IEQ number. The ADIA method showed very high intraobserver reproducibility compared to the standard manual method (p < 0.001). However, islet purity was routinely estimated as significantly higher with the manual method versus the ADIA method (p < 0.001). The ADIA method also detected small islets between 10 and 50 µm in size. Automated digital image analysis utilizing the Nikon Instruments software is an unbiased, simple, and reliable teaching tool to comprehensively assess the individual size of each islet cell preparation prior to transplantation. Implementation of this technology to improve engraftment may help to advance the therapeutic efficacy and accessibility of islet transplantation across centers.
Batch settling curve registration via image data modeling.
Derlon, Nicolas; Thürlimann, Christian; Dürrenmatt, David; Villez, Kris
2017-05-01
To this day, obtaining reliable characterization of sludge settling properties remains a challenging and time-consuming task. Without such assessments however, optimal design and operation of secondary settling tanks is challenging and conservative approaches will remain necessary. With this study, we show that automated sludge blanket height registration and zone settling velocity estimation is possible thanks to analysis of images taken during batch settling experiments. The experimental setup is particularly interesting for practical applications as it consists of off-the-shelf components only, no moving parts are required, and the software is released publicly. Furthermore, the proposed multivariate shape constrained spline model for image analysis appears to be a promising method for reliable sludge blanket height profile registration. Copyright © 2017 Elsevier Ltd. All rights reserved.
2014-01-01
Background A balance test provides important information such as the standard to judge an individual’s functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Methods Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). Results The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. Conclusion The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment. PMID:24912769
Park, Dae-Sung; Lee, GyuChang
2014-06-10
A balance test provides important information such as the standard to judge an individual's functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment.
Comparison of two methods for cardiac output measurement in critically ill patients.
Saraceni, E; Rossi, S; Persona, P; Dan, M; Rizzi, S; Meroni, M; Ori, C
2011-05-01
The aim of recent haemodynamic monitoring has been to obtain continuous and reliable measures of cardiac output (CO) and indices of preload responsiveness. Many of these methods are based on the arterial pressure waveform analysis. The aim of our study was to assess the accuracy of CO measurements obtained by FloTrac/Vigileo, software version 1.07 and the new version 1.10 (Edwards Lifesciences LLC, Irvine, CA, USA), compared with CO measurements obtained by bolus thermodilution by pulmonary artery catheterization (PAC) in the intensive care setting. In 21 critically ill patients (enrolled in two University Hospitals), requiring invasive haemodynamic monitoring, PAC and FloTrac/Vigileo transducers connected to the arterial pressure line were placed. Simultaneous measurements of CO by two methods (FloTrac/Vigileo and thermodilution) were obtained three times a day for 3 consecutive days, when possible. The level of concordance between the two methods was assessed by the procedure suggested by Bland and Altman. One hundred and forty-one pairs of measurements (provided by thermodilution and by both 1.07 and 1.10 FloTrac/Vigileo versions) were obtained in 21 patients (seven of them were trauma patients) with a mean (sd) age of 59 (16) yr. The Pearson product moment coefficient was 0.62 (P<0.001). The bias was -0.18 litre min(-1). The limits of agreement were 4.54 and -4.90 litre min(-1), respectively. Our data show a poor level of concordance between measures provided by the two methods. We found an underestimation of CO values measured with the 1.07 software version of FloTrac for supranormal values of CO. The new software (1.10) has been improved in order to correct this bias; however, its reliability is still poor. On the basis of our data, we can therefore conclude that both software versions of FloTrac/Vigileo did not still provide reliable estimation of CO in our intensive care unit setting.
Fleischer, Luise; Sehner, Susanne; Gehl, Axel; Riemer, Martin; Raupach, Tobias; Anders, Sven
2017-05-01
Measurement of postmortem pupil width is a potential component of death time estimation. However, no standardized measurement method has been described. We analyzed a total of 71 digital images for pupil-iris ratio using the software ImageJ. Images were analyzed three times by four different examiners. In addition, serial images from 10 cases were taken between 2 and 50 h postmortem to detect spontaneous pupil changes. Intra- and inter-rater reliability of the method was excellent (ICC > 0.95). The method is observer independent and yields consistent results, and images can be digitally stored and re-evaluated. The method seems highly eligible for forensic and scientific purposes. While statistical analysis of spontaneous pupil changes revealed a significant polynomial of quartic degree for postmortem time (p = 0.001), an obvious pattern was not detected. These results do not indicate suitability of spontaneous pupil changes for forensic death time estimation, as formerly suggested. © 2016 American Academy of Forensic Sciences.
NASA's Approach to Software Assurance
NASA Technical Reports Server (NTRS)
Wetherholt, Martha
2015-01-01
NASA defines software assurance as: the planned and systematic set of activities that ensure conformance of software life cycle processes and products to requirements, standards, and procedures via quality, safety, reliability, and independent verification and validation. NASA's implementation of this approach to the quality, safety, reliability, security and verification and validation of software is brought together in one discipline, software assurance. Organizationally, NASA has software assurance at each NASA center, a Software Assurance Manager at NASA Headquarters, a Software Assurance Technical Fellow (currently the same person as the SA Manager), and an Independent Verification and Validation Organization with its own facility. An umbrella risk mitigation strategy for safety and mission success assurance of NASA's software, software assurance covers a wide area and is better structured to address the dynamic changes in how software is developed, used, and managed, as well as it's increasingly complex functionality. Being flexible, risk based, and prepared for challenges in software at NASA is essential, especially as much of our software is unique for each mission.
NASA Astrophysics Data System (ADS)
Dulo, D. A.
Safety critical software systems permeate spacecraft, and in a long term venture like a starship would be pervasive in every system of the spacecraft. Yet software failure today continues to plague both the systems and the organizations that develop them resulting in the loss of life, time, money, and valuable system platforms. A starship cannot afford this type of software failure in long journeys away from home. A single software failure could have catastrophic results for the spaceship and the crew onboard. This paper will offer a new approach to developing safe reliable software systems through focusing not on the traditional safety/reliability engineering paradigms but rather by focusing on a new paradigm: Resilience and Failure Obviation Engineering. The foremost objective of this approach is the obviation of failure, coupled with the ability of a software system to prevent or adapt to complex changing conditions in real time as a safety valve should failure occur to ensure safe system continuity. Through this approach, safety is ensured through foresight to anticipate failure and to adapt to risk in real time before failure occurs. In a starship, this type of software engineering is vital. Through software developed in a resilient manner, a starship would have reduced or eliminated software failure, and would have the ability to rapidly adapt should a software system become unstable or unsafe. As a result, long term software safety, reliability, and resilience would be present for a successful long term starship mission.
NASA Technical Reports Server (NTRS)
Fisher, Marcus S.; Northey, Jeffrey; Stanton, William
2014-01-01
The purpose of this presentation is to outline how the NASA Independent Verification and Validation (IVV) Program helps to build reliability into the Space Mission Software Systems (SMSSs) that its customers develop.
Attitude and Trajectory Estimation Using Earth Magnetic Field Data
NASA Technical Reports Server (NTRS)
Deutschmann, Julie; Bar-Itzhack, Itzhack Y.
1996-01-01
The magnetometer has long been a reliable, inexpensive sensor used in spacecraft momentum management and attitude estimation. Recent studies show an increased accuracy potential for magnetometer-only attitude estimation systems. Since the Earth's magnetic field is a function of time and position, and since time is known quite precisely, the differences between the computer and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft orbit, are a function of both the spacecraft trajectory and attitude errors. Therefore, these errors can be used to estimate both trajectory and attitude. Traditionally, satellite attitude and trajectory have been estimated with completely separate system, using different measurement data. Recently, trajectory estimation for low earth orbit satellites was successfully demonstrated in ground software using only magnetometer data. This work proposes a single augmented extended Kalman Filter to simultaneously and autonomously estimate both spacecraft trajectory and attitude with data from a magnetometer and either dynamically determined rates or gyro-measured body rates.
Gutiérrez-Vilahú, Lourdes; Massó-Ortigosa, Núria; Rey-Abella, Ferran; Costa-Tutusaus, Lluís; Guerra-Balic, Myriam
2016-05-01
People with Down syndrome present skeletal abnormalities in their feet that can be analyzed by commonly used gold standard indices (the Hernández-Corvo index, the Chippaux-Smirak index, the Staheli arch index, and the Clarke angle) based on footprint measurements. The use of Photoshop CS5 software (Adobe Systems Software Ireland Ltd, Dublin, Ireland) to measure footprints has been validated in the general population. The present study aimed to assess the reliability and validity of this footprint assessment technique in the population with Down syndrome. Using optical podography and photography, 44 footprints from 22 patients with Down syndrome (11 men [mean ± SD age, 23.82 ± 3.12 years] and 11 women [mean ± SD age, 24.82 ± 6.81 years]) were recorded in a static bipedal standing position. A blinded observer performed the measurements using a validated manual method three times during the 4-month study, with 2 months between measurements. Test-retest was used to check the reliability of the Photoshop CS5 software measurements. Validity and reliability were obtained by intraclass correlation coefficient (ICC). The reliability test for all of the indices showed very good values for the Photoshop CS5 method (ICC, 0.982-0.995). Validity testing also found no differences between the techniques (ICC, 0.988-0.999). The Photoshop CS5 software method is reliable and valid for the study of footprints in young people with Down syndrome.
Managing Complexity in Next Generation Robotic Spacecraft: From a Software Perspective
NASA Technical Reports Server (NTRS)
Reinholtz, Kirk
2008-01-01
This presentation highlights the challenges in the design of software to support robotic spacecraft. Robotic spacecraft offer a higher degree of autonomy, however currently more capabilities are required, primarily in the software, while providing the same or higher degree of reliability. The complexity of designing such an autonomous system is great, particularly while attempting to address the needs for increased capabilities and high reliability without increased needs for time or money. The efforts to develop programming models for the new hardware and the integration of software architecture are highlighted.
Towards early software reliability prediction for computer forensic tools (case study).
Abu Talib, Manar
2016-01-01
Versatility, flexibility and robustness are essential requirements for software forensic tools. Researchers and practitioners need to put more effort into assessing this type of tool. A Markov model is a robust means for analyzing and anticipating the functioning of an advanced component based system. It is used, for instance, to analyze the reliability of the state machines of real time reactive systems. This research extends the architecture-based software reliability prediction model for computer forensic tools, which is based on Markov chains and COSMIC-FFP. Basically, every part of the computer forensic tool is linked to a discrete time Markov chain. If this can be done, then a probabilistic analysis by Markov chains can be performed to analyze the reliability of the components and of the whole tool. The purposes of the proposed reliability assessment method are to evaluate the tool's reliability in the early phases of its development, to improve the reliability assessment process for large computer forensic tools over time, and to compare alternative tool designs. The reliability analysis can assist designers in choosing the most reliable topology for the components, which can maximize the reliability of the tool and meet the expected reliability level specified by the end-user. The approach of assessing component-based tool reliability in the COSMIC-FFP context is illustrated with the Forensic Toolkit Imager case study.
Evaluation of the efficiency and fault density of software generated by code generators
NASA Technical Reports Server (NTRS)
Schreur, Barbara
1993-01-01
Flight computers and flight software are used for GN&C (guidance, navigation, and control), engine controllers, and avionics during missions. The software development requires the generation of a considerable amount of code. The engineers who generate the code make mistakes and the generation of a large body of code with high reliability requires considerable time. Computer-aided software engineering (CASE) tools are available which generates code automatically with inputs through graphical interfaces. These tools are referred to as code generators. In theory, code generators could write highly reliable code quickly and inexpensively. The various code generators offer different levels of reliability checking. Some check only the finished product while some allow checking of individual modules and combined sets of modules as well. Considering NASA's requirement for reliability, an in house manually generated code is needed. Furthermore, automatically generated code is reputed to be as efficient as the best manually generated code when executed. In house verification is warranted.
Luján, Manel; Sogo, Ana; Pomares, Xavier; Monsó, Eduard; Sales, Bernat; Blanch, Lluís
2013-05-01
New home ventilators are able to provide clinicians data of interest through built-in software. Monitoring of tidal volume (VT) is a key point in the assessment of the efficacy of home mechanical ventilation. To assess the reliability of the VT provided by 5 ventilators in a bench test. Five commercial ventilators from 4 different manufacturers were tested in pressure support mode with the help of a breathing simulator under different conditions of mechanical respiratory pattern, inflation pressure, and intentional leakage. Values provided by the built-in software of each ventilator were compared breath to breath with the VT monitored through an external pneumotachograph. Ten breaths for each condition were compared for every tested situation. All tested ventilators underestimated VT (ranges of -21.7 mL to -83.5 mL, which corresponded to -3.6% to -14.7% of the externally measured VT). A direct relationship between leak and underestimation was found in 4 ventilators, with higher underestimations of the VT when the leakage increased, ranging between -2.27% and -5.42% for each 10 L/min increase in the leakage. A ventilator that included an algorithm that computes the pressure loss through the tube as a function of the flow exiting the ventilator had the minimal effect of leaks on the estimation of VT (0.3%). In 3 ventilators the underestimation was also influenced by mechanical pattern (lower underestimation with restrictive, and higher with obstructive). The inclusion of algorithms that calculate the pressure loss as a function of the flow exiting the ventilator in commercial models may increase the reliability of VT estimation.
Software Reliability Issues Concerning Large and Safety Critical Software Systems
NASA Technical Reports Server (NTRS)
Kamel, Khaled; Brown, Barbara
1996-01-01
This research was undertaken to provide NASA with a survey of state-of-the-art techniques using in industrial and academia to provide safe, reliable, and maintainable software to drive large systems. Such systems must match the complexity and strict safety requirements of NASA's shuttle system. In particular, the Launch Processing System (LPS) is being considered for replacement. The LPS is responsible for monitoring and commanding the shuttle during test, repair, and launch phases. NASA built this system in the 1970's using mostly hardware techniques to provide for increased reliability, but it did so often using custom-built equipment, which has not been able to keep up with current technologies. This report surveys the major techniques used in industry and academia to ensure reliability in large and critical computer systems.
Negoita, Madalina; Zolgharni, Massoud; Dadkho, Elham; Pernigo, Matteo; Mielewczik, Michael; Cole, Graham D; Dhutia, Niti M; Francis, Darrel P
2016-09-01
To determine the optimal frame rate at which reliable heart walls velocities can be assessed by speckle tracking. Assessing left ventricular function with speckle tracking is useful in patient diagnosis but requires a temporal resolution that can follow myocardial motion. In this study we investigated the effect of different frame rates on the accuracy of speckle tracking results, highlighting the temporal resolution where reliable results can be obtained. 27 patients were scanned at two different frame rates at their resting heart rate. From all acquired loops, lower temporal resolution image sequences were generated by dropping frames, decreasing the frame rate by up to 10-fold. Tissue velocities were estimated by automated speckle tracking. Above 40 frames/s the peak velocity was reliably measured. When frame rate was lower, the inter-frame interval containing the instant of highest velocity also contained lower velocities, and therefore the average velocity in that interval was an underestimate of the clinically desired instantaneous maximum velocity. The higher the frame rate, the more accurately maximum velocities are identified by speckle tracking, until the frame rate drops below 40 frames/s, beyond which there is little increase in peak velocity. We provide in an online supplement the vendor-independent software we used for automatic speckle-tracked velocity assessment to help others working in this field. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Design and reliability analysis of DP-3 dynamic positioning control architecture
NASA Astrophysics Data System (ADS)
Wang, Fang; Wan, Lei; Jiang, Da-Peng; Xu, Yu-Ru
2011-12-01
As the exploration and exploitation of oil and gas proliferate throughout deepwater area, the requirements on the reliability of dynamic positioning system become increasingly stringent. The control objective ensuring safety operation at deep water will not be met by a single controller for dynamic positioning. In order to increase the availability and reliability of dynamic positioning control system, the triple redundancy hardware and software control architectures were designed and developed according to the safe specifications of DP-3 classification notation for dynamically positioned ships and rigs. The hardware redundant configuration takes the form of triple-redundant hot standby configuration including three identical operator stations and three real-time control computers which connect each other through dual networks. The function of motion control and redundancy management of control computers were implemented by software on the real-time operating system VxWorks. The software realization of task loose synchronization, majority voting and fault detection were presented in details. A hierarchical software architecture was planed during the development of software, consisting of application layer, real-time layer and physical layer. The behavior of the DP-3 dynamic positioning control system was modeled by a Markov model to analyze its reliability. The effects of variation in parameters on the reliability measures were investigated. The time domain dynamic simulation was carried out on a deepwater drilling rig to prove the feasibility of the proposed control architecture.
Ratnayake, M; Obertová, Z; Dose, M; Gabriel, P; Bröker, H M; Brauckmann, M; Barkus, A; Rizgeliene, R; Tutkuviene, J; Ritz-Timme, S; Marasciuolo, L; Gibelli, D; Cattaneo, C
2014-09-01
In cases of suspected child pornography, the age of the victim represents a crucial factor for legal prosecution. The conventional methods for age estimation provide unreliable age estimates, particularly if teenage victims are concerned. In this pilot study, the potential of age estimation for screening purposes is explored for juvenile faces. In addition to a visual approach, an automated procedure is introduced, which has the ability to rapidly scan through large numbers of suspicious image data in order to trace juvenile faces. Age estimations were performed by experts, non-experts and the Demonstrator of a developed software on frontal facial images of 50 females aged 10-19 years from Germany, Italy, and Lithuania. To test the accuracy, the mean absolute error (MAE) between the estimates and the real ages was calculated for each examiner and the Demonstrator. The Demonstrator achieved the lowest MAE (1.47 years) for the 50 test images. Decreased image quality had no significant impact on the performance and classification results. The experts delivered slightly less accurate MAE (1.63 years). Throughout the tested age range, both the manual and the automated approach led to reliable age estimates within the limits of natural biological variability. The visual analysis of the face produces reasonably accurate age estimates up to the age of 18 years, which is the legally relevant age threshold for victims in cases of pedo-pornography. This approach can be applied in conjunction with the conventional methods for a preliminary age estimation of juveniles depicted on images.
Developing of an automation for therapy dosimetry systems by using labview software
NASA Astrophysics Data System (ADS)
Aydin, Selim; Kam, Erol
2018-06-01
Traceability, accuracy and consistency of radiation measurements are essential in radiation dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent on the radiation dose delivered to patients. Therefore it is very important to provide reliable, accurate and fast calibration services for therapy dosimeters since the radiation dose delivered to a radiotherapy patient is directly related to accuracy and reliability of these devices. In this study, we report the performance of in-house developed computer controlled data acquisition and monitoring software for the commercially available radiation therapy electrometers. LabVIEW® software suite is used to provide reliable, fast and accurate calibration services. The software also collects environmental data such as temperature, pressure and humidity in order to use to use these them in correction factor calculations. By using this software tool, a better control over the calibration process is achieved and the need for human intervention is reduced. This is the first software that can control frequently used dosimeter systems, in radiation thereapy field at hospitals, such as Unidos Webline, Unidos E, Dose-1 and PC Electrometers.
Development of a Standard Set of Software Indicators for Aeronautical Systems Center.
1992-09-01
29:12). The composite models listed include COCOMO and the Software Productivity, Quality, and Reliability Model ( SPQR ) (29:12). The SPQR model was...determine the values of the 68 input parameters. Source provides no specifics. Indicator Name SPQR (SW Productivity, Qual, Reliability) Indicator Class
On the use and the performance of software reliability growth models
NASA Technical Reports Server (NTRS)
Keiller, Peter A.; Miller, Douglas R.
1991-01-01
We address the problem of predicting future failures for a piece of software. The number of failures occurring during a finite future time interval is predicted from the number failures observed during an initial period of usage by using software reliability growth models. Two different methods for using the models are considered: straightforward use of individual models, and dynamic selection among models based on goodness-of-fit and quality-of-prediction criteria. Performance is judged by the relative error of the predicted number of failures over future finite time intervals relative to the number of failures eventually observed during the intervals. Six of the former models and eight of the latter are evaluated, based on their performance on twenty data sets. Many open questions remain regarding the use and the performance of software reliability growth models.
Effectiveness of back-to-back testing
NASA Technical Reports Server (NTRS)
Vouk, Mladen A.; Mcallister, David F.; Eckhardt, David E.; Caglayan, Alper; Kelly, John P. J.
1987-01-01
Three models of back-to-back testing processes are described. Two models treat the case where there is no intercomponent failure dependence. The third model describes the more realistic case where there is correlation among the failure probabilities of the functionally equivalent components. The theory indicates that back-to-back testing can, under the right conditions, provide a considerable gain in software reliability. The models are used to analyze the data obtained in a fault-tolerant software experiment. It is shown that the expected gain is indeed achieved, and exceeded, provided the intercomponent failure dependence is sufficiently small. However, even with the relatively high correlation the use of several functionally equivalent components coupled with back-to-back testing may provide a considerable reliability gain. Implications of this finding are that the multiversion software development is a feasible and cost effective approach to providing highly reliable software components intended for fault-tolerant software systems, on condition that special attention is directed at early detection and elimination of correlated faults.
Discrete Address Beacon System (DABS) Software System Reliability Modeling and Prediction.
1981-06-01
Service ( ATARS ) module because of its interim status. Reliability prediction models for software modules were derived and then verified by matching...System (A’iCR3BS) and thus can be introduced gradually and economically without ma jor olper- ational or procedural change. Since DABS uses monopulse...lineanaly- sis tools or are ured during maintenance or pre-initialization were not modeled because they are not part of the mission software. The ATARS
Estimating Software-Development Costs With Greater Accuracy
NASA Technical Reports Server (NTRS)
Baker, Dan; Hihn, Jairus; Lum, Karen
2008-01-01
COCOMOST is a computer program for use in estimating software development costs. The goal in the development of COCOMOST was to increase estimation accuracy in three ways: (1) develop a set of sensitivity software tools that return not only estimates of costs but also the estimation error; (2) using the sensitivity software tools, precisely define the quantities of data needed to adequately tune cost estimation models; and (3) build a repository of software-cost-estimation information that NASA managers can retrieve to improve the estimates of costs of developing software for their project. COCOMOST implements a methodology, called '2cee', in which a unique combination of well-known pre-existing data-mining and software-development- effort-estimation techniques are used to increase the accuracy of estimates. COCOMOST utilizes multiple models to analyze historical data pertaining to software-development projects and performs an exhaustive data-mining search over the space of model parameters to improve the performances of effort-estimation models. Thus, it is possible to both calibrate and generate estimates at the same time. COCOMOST is written in the C language for execution in the UNIX operating system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, Tsong-Lun; Varuttamaseni, Athi; Baek, Joo-Seok
The U.S. Nuclear Regulatory Commission (NRC) encourages the use of probabilistic risk assessment (PRA) technology in all regulatory matters, to the extent supported by the state-of-the-art in PRA methods and data. Although much has been accomplished in the area of risk-informed regulation, risk assessment for digital systems has not been fully developed. The NRC established a plan for research on digital systems to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems in the PRAs of nuclear power plants (NPPs), and (2) incorporating digital systems in the NRC's risk-informed licensing and oversight activities.more » Under NRC's sponsorship, Brookhaven National Laboratory (BNL) explored approaches for addressing the failures of digital instrumentation and control (I and C) systems in the current NPP PRA framework. Specific areas investigated included PRA modeling digital hardware, development of a philosophical basis for defining software failure, and identification of desirable attributes of quantitative software reliability methods. Based on the earlier research, statistical testing is considered a promising method for quantifying software reliability. This paper describes a statistical software testing approach for quantifying software reliability and applies it to the loop-operating control system (LOCS) of an experimental loop of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL).« less
Kim, Kwang Baek; Kim, Chang Won
2015-01-01
Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future.
Kim, Kwang Baek
2015-01-01
Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future. PMID:26247023
Reliability measurement during software development. [for a multisensor tracking system
NASA Technical Reports Server (NTRS)
Hecht, H.; Sturm, W. A.; Trattner, S.
1977-01-01
During the development of data base software for a multi-sensor tracking system, reliability was measured. The failure ratio and failure rate were found to be consistent measures. Trend lines were established from these measurements that provided good visualization of the progress on the job as a whole as well as on individual modules. Over one-half of the observed failures were due to factors associated with the individual run submission rather than with the code proper. Possible application of these findings for line management, project managers, functional management, and regulatory agencies is discussed. Steps for simplifying the measurement process and for use of these data in predicting operational software reliability are outlined.
Space Shuttle Software Development and Certification
NASA Technical Reports Server (NTRS)
Orr, James K.; Henderson, Johnnie A
2000-01-01
Man-rated software, "software which is in control of systems and environments upon which human life is critically dependent," must be highly reliable. The Space Shuttle Primary Avionics Software System is an excellent example of such a software system. Lessons learn from more than 20 years of effort have identified basic elements that must be present to achieve this high degree of reliability. The elements include rigorous application of appropriate software development processes, use of trusted tools to support those processes, quantitative process management, and defect elimination and prevention. This presentation highlights methods used within the Space Shuttle project and raises questions that must be addressed to provide similar success in a cost effective manner on future long-term projects where key application development tools are COTS rather than internally developed custom application development tools
Launch vehicle operations cost reduction through artificial intelligence techniques
NASA Technical Reports Server (NTRS)
Davis, Tom C., Jr.
1988-01-01
NASA's Kennedy Space Center has attempted to develop AI methods in order to reduce the cost of launch vehicle ground operations as well as to improve the reliability and safety of such operations. Attention is presently given to cost savings estimates for systems involving launch vehicle firing-room software and hardware real-time diagnostics, as well as the nature of configuration control and the real-time autonomous diagnostics of launch-processing systems by these means. Intelligent launch decisions and intelligent weather forecasting are additional applications of AI being considered.
Automatic Speech Recognition: Reliability and Pedagogical Implications for Teaching Pronunciation
ERIC Educational Resources Information Center
Kim, In-Seok
2006-01-01
This study examines the reliability of automatic speech recognition (ASR) software used to teach English pronunciation, focusing on one particular piece of software, "FluSpeak, as a typical example." Thirty-six Korean English as a Foreign Language (EFL) college students participated in an experiment in which they listened to 15 sentences…
Software service history report
DOT National Transportation Integrated Search
2002-01-01
The safe and reliable operation of software within civil aviation systems and equipment has historically been assured through the application of rigorous design assurance applied during the software development process. Increasingly, manufacturers ar...
A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.
Koo, Terry K; Li, Mae Y
2016-06-01
Intraclass correlation coefficient (ICC) is a widely used reliability index in test-retest, intrarater, and interrater reliability analyses. This article introduces the basic concept of ICC in the content of reliability analysis. There are 10 forms of ICCs. Because each form involves distinct assumptions in their calculation and will lead to different interpretations, researchers should explicitly specify the ICC form they used in their calculation. A thorough review of the research design is needed in selecting the appropriate form of ICC to evaluate reliability. The best practice of reporting ICC should include software information, "model," "type," and "definition" selections. When coming across an article that includes ICC, readers should first check whether information about the ICC form has been reported and if an appropriate ICC form was used. Based on the 95% confident interval of the ICC estimate, values less than 0.5, between 0.5 and 0.75, between 0.75 and 0.9, and greater than 0.90 are indicative of poor, moderate, good, and excellent reliability, respectively. This article provides a practical guideline for clinical researchers to choose the correct form of ICC and suggests the best practice of reporting ICC parameters in scientific publications. This article also gives readers an appreciation for what to look for when coming across ICC while reading an article.
Reliability, Safety and Error Recovery for Advanced Control Software
NASA Technical Reports Server (NTRS)
Malin, Jane T.
2003-01-01
For long-duration automated operation of regenerative life support systems in space environments, there is a need for advanced integration and control systems that are significantly more reliable and safe, and that support error recovery and minimization of operational failures. This presentation outlines some challenges of hazardous space environments and complex system interactions that can lead to system accidents. It discusses approaches to hazard analysis and error recovery for control software and challenges of supporting effective intervention by safety software and the crew.
Practical Methods for Estimating Software Systems Fault Content and Location
NASA Technical Reports Server (NTRS)
Nikora, A.; Schneidewind, N.; Munson, J.
1999-01-01
Over the past several years, we have developed techniques to discriminate between fault-prone software modules and those that are not, to estimate a software system's residual fault content, to identify those portions of a software system having the highest estimated number of faults, and to estimate the effects of requirements changes on software quality.
Development and analysis of the Software Implemented Fault-Tolerance (SIFT) computer
NASA Technical Reports Server (NTRS)
Goldberg, J.; Kautz, W. H.; Melliar-Smith, P. M.; Green, M. W.; Levitt, K. N.; Schwartz, R. L.; Weinstock, C. B.
1984-01-01
SIFT (Software Implemented Fault Tolerance) is an experimental, fault-tolerant computer system designed to meet the extreme reliability requirements for safety-critical functions in advanced aircraft. Errors are masked by performing a majority voting operation over the results of identical computations, and faulty processors are removed from service by reassigning computations to the nonfaulty processors. This scheme has been implemented in a special architecture using a set of standard Bendix BDX930 processors, augmented by a special asynchronous-broadcast communication interface that provides direct, processor to processor communication among all processors. Fault isolation is accomplished in hardware; all other fault-tolerance functions, together with scheduling and synchronization are implemented exclusively by executive system software. The system reliability is predicted by a Markov model. Mathematical consistency of the system software with respect to the reliability model has been partially verified, using recently developed tools for machine-aided proof of program correctness.
Cros, David; Sánchez, Leopoldo; Cochard, Benoit; Samper, Patrick; Denis, Marie; Bouvet, Jean-Marc; Fernández, Jesús
2014-04-01
Explicit pedigree reconstruction by simulated annealing gave reliable estimates of genealogical coancestry in plant species, especially when selfing rate was lower than 0.6, using a realistic number of markers. Genealogical coancestry information is crucial in plant breeding to estimate genetic parameters and breeding values. The approach of Fernández and Toro (Mol Ecol 15:1657-1667, 2006) to estimate genealogical coancestries from molecular data through pedigree reconstruction was limited to species with separate sexes. In this study it was extended to plants, allowing hermaphroditism and monoecy, with possible selfing. Moreover, some improvements were made to take previous knowledge on the population demographic history into account. The new method was validated using simulated and real datasets. Simulations showed that accuracy of estimates was high with 30 microsatellites, with the best results obtained for selfing rates below 0.6. In these conditions, the root mean square error (RMSE) between the true and estimated genealogical coancestry was small (<0.07), although the number of ancestors was overestimated and the selfing rate could be biased. Simulations also showed that linkage disequilibrium between markers and departure from the Hardy-Weinberg equilibrium in the founder population did not affect the efficiency of the method. Real oil palm data confirmed the simulation results, with a high correlation between the true and estimated genealogical coancestry (>0.9) and a low RMSE (<0.08) using 38 markers. The method was applied to the Deli oil palm population for which pedigree data were scarce. The estimated genealogical coancestries were highly correlated (>0.9) with the molecular coancestries using 100 markers. Reconstructed pedigrees were used to estimate effective population sizes. In conclusion, this method gave reliable genealogical coancestry estimates. The strategy was implemented in the software MOLCOANC 3.0.
Evaluation methodologies for an advanced information processing system
NASA Technical Reports Server (NTRS)
Schabowsky, R. S., Jr.; Gai, E.; Walker, B. K.; Lala, J. H.; Motyka, P.
1984-01-01
The system concept and requirements for an Advanced Information Processing System (AIPS) are briefly described, but the emphasis of this paper is on the evaluation methodologies being developed and utilized in the AIPS program. The evaluation tasks include hardware reliability, maintainability and availability, software reliability, performance, and performability. Hardware RMA and software reliability are addressed with Markov modeling techniques. The performance analysis for AIPS is based on queueing theory. Performability is a measure of merit which combines system reliability and performance measures. The probability laws of the performance measures are obtained from the Markov reliability models. Scalar functions of this law such as the mean and variance provide measures of merit in the AIPS performability evaluations.
Zhang, Zhiyong; Yuan, Ke-Hai
2016-06-01
Cronbach's coefficient alpha is a widely used reliability measure in social, behavioral, and education sciences. It is reported in nearly every study that involves measuring a construct through multiple items. With non-tau-equivalent items, McDonald's omega has been used as a popular alternative to alpha in the literature. Traditional estimation methods for alpha and omega often implicitly assume that data are complete and normally distributed. This study proposes robust procedures to estimate both alpha and omega as well as corresponding standard errors and confidence intervals from samples that may contain potential outlying observations and missing values. The influence of outlying observations and missing data on the estimates of alpha and omega is investigated through two simulation studies. Results show that the newly developed robust method yields substantially improved alpha and omega estimates as well as better coverage rates of confidence intervals than the conventional nonrobust method. An R package coefficientalpha is developed and demonstrated to obtain robust estimates of alpha and omega.
A Bayesian Approach to More Stable Estimates of Group-Level Effects in Contextual Studies.
Zitzmann, Steffen; Lüdtke, Oliver; Robitzsch, Alexander
2015-01-01
Multilevel analyses are often used to estimate the effects of group-level constructs. However, when using aggregated individual data (e.g., student ratings) to assess a group-level construct (e.g., classroom climate), the observed group mean might not provide a reliable measure of the unobserved latent group mean. In the present article, we propose a Bayesian approach that can be used to estimate a multilevel latent covariate model, which corrects for the unreliable assessment of the latent group mean when estimating the group-level effect. A simulation study was conducted to evaluate the choice of different priors for the group-level variance of the predictor variable and to compare the Bayesian approach with the maximum likelihood approach implemented in the software Mplus. Results showed that, under problematic conditions (i.e., small number of groups, predictor variable with a small ICC), the Bayesian approach produced more accurate estimates of the group-level effect than the maximum likelihood approach did.
Maximum likelihood techniques applied to quasi-elastic light scattering
NASA Technical Reports Server (NTRS)
Edwards, Robert V.
1992-01-01
There is a necessity of having an automatic procedure for reliable estimation of the quality of the measurement of particle size from QELS (Quasi-Elastic Light Scattering). Getting the measurement itself, before any error estimates can be made, is a problem because it is obtained by a very indirect measurement of a signal derived from the motion of particles in the system and requires the solution of an inverse problem. The eigenvalue structure of the transform that generates the signal is such that an arbitrarily small amount of noise can obliterate parts of any practical inversion spectrum. This project uses the Maximum Likelihood Estimation (MLE) as a framework to generate a theory and a functioning set of software to oversee the measurement process and extract the particle size information, while at the same time providing error estimates for those measurements. The theory involved verifying a correct form of the covariance matrix for the noise on the measurement and then estimating particle size parameters using a modified histogram approach.
Final Report of the NASA Office of Safety and Mission Assurance Agile Benchmarking Team
NASA Technical Reports Server (NTRS)
Wetherholt, Martha
2016-01-01
To ensure that the NASA Safety and Mission Assurance (SMA) community remains in a position to perform reliable Software Assurance (SA) on NASAs critical software (SW) systems with the software industry rapidly transitioning from waterfall to Agile processes, Terry Wilcutt, Chief, Safety and Mission Assurance, Office of Safety and Mission Assurance (OSMA) established the Agile Benchmarking Team (ABT). The Team's tasks were: 1. Research background literature on current Agile processes, 2. Perform benchmark activities with other organizations that are involved in software Agile processes to determine best practices, 3. Collect information on Agile-developed systems to enable improvements to the current NASA standards and processes to enhance their ability to perform reliable software assurance on NASA Agile-developed systems, 4. Suggest additional guidance and recommendations for updates to those standards and processes, as needed. The ABT's findings and recommendations for software management, engineering and software assurance are addressed herein.
Evaluation of the efficiency and reliability of software generated by code generators
NASA Technical Reports Server (NTRS)
Schreur, Barbara
1994-01-01
There are numerous studies which show that CASE Tools greatly facilitate software development. As a result of these advantages, an increasing amount of software development is done with CASE Tools. As more software engineers become proficient with these tools, their experience and feedback lead to further development with the tools themselves. What has not been widely studied, however, is the reliability and efficiency of the actual code produced by the CASE Tools. This investigation considered these matters. Three segments of code generated by MATRIXx, one of many commercially available CASE Tools, were chosen for analysis: ETOFLIGHT, a portion of the Earth to Orbit Flight software, and ECLSS and PFMC, modules for Environmental Control and Life Support System and Pump Fan Motor Control, respectively.
NASA software specification and evaluation system design, part 2
NASA Technical Reports Server (NTRS)
1976-01-01
A survey and analysis of the existing methods, tools and techniques employed in the development of software are presented along with recommendations for the construction of reliable software. Functional designs for software specification language, and the data base verifier are presented.
Effective Software Engineering Leadership for Development Programs
ERIC Educational Resources Information Center
Cagle West, Marsha
2010-01-01
Software is a critical component of systems ranging from simple consumer appliances to complex health, nuclear, and flight control systems. The development of quality, reliable, and effective software solutions requires the incorporation of effective software engineering processes and leadership. Processes, approaches, and methodologies for…
Modeling SMAP Spacecraft Attitude Control Estimation Error Using Signal Generation Model
NASA Technical Reports Server (NTRS)
Rizvi, Farheen
2016-01-01
Two ground simulation software are used to model the SMAP spacecraft dynamics. The CAST software uses a higher fidelity model than the ADAMS software. The ADAMS software models the spacecraft plant, controller and actuator models, and assumes a perfect sensor and estimator model. In this simulation study, the spacecraft dynamics results from the ADAMS software are used as CAST software is unavailable. The main source of spacecraft dynamics error in the higher fidelity CAST software is due to the estimation error. A signal generation model is developed to capture the effect of this estimation error in the overall spacecraft dynamics. Then, this signal generation model is included in the ADAMS software spacecraft dynamics estimate such that the results are similar to CAST. This signal generation model has similar characteristics mean, variance and power spectral density as the true CAST estimation error. In this way, ADAMS software can still be used while capturing the higher fidelity spacecraft dynamics modeling from CAST software.
Khadilkar, Leenesh; MacDermid, Joy C; Sinden, Kathryn E; Jenkyn, Thomas R; Birmingham, Trevor B; Athwal, George S
2014-01-01
Video-based movement analysis software (Dartfish) has potential for clinical applications for understanding shoulder motion if functional measures can be reliably obtained. The primary purpose of this study was to describe the functional range of motion (ROM) of the shoulder used to perform a subset of functional tasks. A second purpose was to assess the reliability of functional ROM measurements obtained by different raters using Dartfish software. Ten healthy participants, mean age 29 ± 5 years, were videotaped while performing five tasks selected from the Disabilities of the Arm, Shoulder and Hand (DASH). Video cameras and markers were used to obtain video images suitable for analysis in Dartfish software. Three repetitions of each task were performed. Shoulder movements from all three repetitions were analyzed using Dartfish software. The tracking tool of the Dartfish software was used to obtain shoulder joint angles and arcs of motion. Test-retest and inter-rater reliability of the measurements were evaluated using intraclass correlation coefficients (ICC). Maximum (coronal plane) abduction (118° ± 16°) and (sagittal plane) flexion (111° ± 15°) was observed during 'washing one's hair;' maximum extension (-68° ± 9°) was identified during 'washing one's own back.' Minimum shoulder ROM was observed during 'opening a tight jar' (33° ± 13° abduction and 13° ± 19° flexion). Test-retest reliability (ICC = 0.45 to 0.94) suggests high inter-individual task variability, and inter-rater reliability (ICC = 0.68 to 1.00) showed moderate to excellent agreement. KEY FINDINGS INCLUDE: 1) functional shoulder ROM identified in this study compared to similar studies; 2) healthy individuals require less than full ROM when performing five common ADL tasks 3) high participant variability was observed during performance of the five ADL tasks; and 4) Dartfish software provides a clinically relevant tool to analyze shoulder function.
Finding and estimating chemical property data for environmental assessment.
Boethling, Robert S; Howard, Philip H; Meylan, William M
2004-10-01
The ability to predict the behavior of a chemical substance in a biological or environmental system largely depends on knowledge of the physicochemical properties and reactivity of that substance. We focus here on properties, with the objective of providing practical guidance for finding measured values and using estimation methods when necessary. Because currently available computer software often makes it more convenient to estimate than to retrieve measured values, we try to discourage irrational exuberance for these tools by including comprehensive lists of Internet and hard-copy data resources. Guidance for assessors is presented in the form of a process to obtain data that includes establishment of chemical identity, identification of data sources, assessment of accuracy and reliability, substructure searching for analogs when experimental data are unavailable, and estimation from chemical structure. Regarding property estimation, we cover estimation from close structural analogs in addition to broadly applicable methods requiring only the chemical structure. For the latter, we list and briefly discuss the most widely used methods. Concluding thoughts are offered concerning appropriate directions for future work on estimation methods, again with an emphasis on practical applications.
Assuring Software Cost Estimates: Is it an Oxymoron?
NASA Technical Reports Server (NTRS)
Hihn, Jarius; Tregre, Grant
2013-01-01
The software industry repeatedly observes cost growth of well over 100% even after decades of cost estimation research and well-known best practices, so "What's the problem?" In this paper we will provide an overview of the current state oj software cost estimation best practice. We then explore whether applying some of the methods used in software assurance might improve the quality of software cost estimates. This paper especially focuses on issues associated with model calibration, estimate review, and the development and documentation of estimates as part alan integrated plan.
Analyzing Responses of Chemical Sensor Arrays
NASA Technical Reports Server (NTRS)
Zhou, Hanying
2007-01-01
NASA is developing a third-generation electronic nose (ENose) capable of continuous monitoring of the International Space Station s cabin atmosphere for specific, harmful airborne contaminants. Previous generations of the ENose have been described in prior NASA Tech Briefs issues. Sensor selection is critical in both (prefabrication) sensor material selection and (post-fabrication) data analysis of the ENose, which detects several analytes that are difficult to detect, or that are at very low concentration ranges. Existing sensor selection approaches usually include limited statistical measures, where selectivity is more important but reliability and sensitivity are not of concern. When reliability and sensitivity can be major limiting factors in detecting target compounds reliably, the existing approach is not able to provide meaningful selection that will actually improve data analysis results. The approach and software reported here consider more statistical measures (factors) than existing approaches for a similar purpose. The result is a more balanced and robust sensor selection from a less than ideal sensor array. The software offers quick, flexible, optimal sensor selection and weighting for a variety of purposes without a time-consuming, iterative search by performing sensor calibrations to a known linear or nonlinear model, evaluating the individual sensor s statistics, scoring the individual sensor s overall performance, finding the best sensor array size to maximize class separation, finding optimal weights for the remaining sensor array, estimating limits of detection for the target compounds, evaluating fingerprint distance between group pairs, and finding the best event-detecting sensors.
Study of a unified hardware and software fault-tolerant architecture
NASA Technical Reports Server (NTRS)
Lala, Jaynarayan; Alger, Linda; Friend, Steven; Greeley, Gregory; Sacco, Stephen; Adams, Stuart
1989-01-01
A unified architectural concept, called the Fault Tolerant Processor Attached Processor (FTP-AP), that can tolerate hardware as well as software faults is proposed for applications requiring ultrareliable computation capability. An emulation of the FTP-AP architecture, consisting of a breadboard Motorola 68010-based quadruply redundant Fault Tolerant Processor, four VAX 750s as attached processors, and four versions of a transport aircraft yaw damper control law, is used as a testbed in the AIRLAB to examine a number of critical issues. Solutions of several basic problems associated with N-Version software are proposed and implemented on the testbed. This includes a confidence voter to resolve coincident errors in N-Version software. A reliability model of N-Version software that is based upon the recent understanding of software failure mechanisms is also developed. The basic FTP-AP architectural concept appears suitable for hosting N-Version application software while at the same time tolerating hardware failures. Architectural enhancements for greater efficiency, software reliability modeling, and N-Version issues that merit further research are identified.
An approach to software cost estimation
NASA Technical Reports Server (NTRS)
Mcgarry, F.; Page, J.; Card, D.; Rohleder, M.; Church, V.
1984-01-01
A general procedure for software cost estimation in any environment is outlined. The basic concepts of work and effort estimation are explained, some popular resource estimation models are reviewed, and the accuracy of source estimates is discussed. A software cost prediction procedure based on the experiences of the Software Engineering Laboratory in the flight dynamics area and incorporating management expertise, cost models, and historical data is described. The sources of information and relevant parameters available during each phase of the software life cycle are identified. The methodology suggested incorporates these elements into a customized management tool for software cost prediction. Detailed guidelines for estimation in the flight dynamics environment developed using this methodology are presented.
Assessing Survivability Using Software Fault Injection
2001-04-01
UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADPO10875 TITLE: Assessing Survivability Using Software Fault Injection...Esc to exit .......................................................................... = 11-1 Assessing Survivability Using Software Fault Injection...Jeffrey Voas Reliable Software Technologies 21351 Ridgetop Circle, #400 Dulles, VA 20166 jmvoas@rstcorp.crom Abstract approved sources have the
Vaas, Lea A I; Sikorski, Johannes; Michael, Victoria; Göker, Markus; Klenk, Hans-Peter
2012-01-01
The Phenotype MicroArray (OmniLog® PM) system is able to simultaneously capture a large number of phenotypes by recording an organism's respiration over time on distinct substrates. This technique targets the object of natural selection itself, the phenotype, whereas previously addressed '-omics' techniques merely study components that finally contribute to it. The recording of respiration over time, however, adds a longitudinal dimension to the data. To optimally exploit this information, it must be extracted from the shapes of the recorded curves and displayed in analogy to conventional growth curves. The free software environment R was explored for both visualizing and fitting of PM respiration curves. Approaches using either a model fit (and commonly applied growth models) or a smoothing spline were evaluated. Their reliability in inferring curve parameters and confidence intervals was compared to the native OmniLog® PM analysis software. We consider the post-processing of the estimated parameters, the optimal classification of curve shapes and the detection of significant differences between them, as well as practically relevant questions such as detecting the impact of cultivation times and the minimum required number of experimental repeats. We provide a comprehensive framework for data visualization and parameter estimation according to user choices. A flexible graphical representation strategy for displaying the results is proposed, including 95% confidence intervals for the estimated parameters. The spline approach is less prone to irregular curve shapes than fitting any of the considered models or using the native PM software for calculating both point estimates and confidence intervals. These can serve as a starting point for the automated post-processing of PM data, providing much more information than the strict dichotomization into positive and negative reactions. Our results form the basis for a freely available R package for the analysis of PM data.
Vaas, Lea A. I.; Sikorski, Johannes; Michael, Victoria; Göker, Markus; Klenk, Hans-Peter
2012-01-01
Background The Phenotype MicroArray (OmniLog® PM) system is able to simultaneously capture a large number of phenotypes by recording an organism's respiration over time on distinct substrates. This technique targets the object of natural selection itself, the phenotype, whereas previously addressed ‘-omics’ techniques merely study components that finally contribute to it. The recording of respiration over time, however, adds a longitudinal dimension to the data. To optimally exploit this information, it must be extracted from the shapes of the recorded curves and displayed in analogy to conventional growth curves. Methodology The free software environment R was explored for both visualizing and fitting of PM respiration curves. Approaches using either a model fit (and commonly applied growth models) or a smoothing spline were evaluated. Their reliability in inferring curve parameters and confidence intervals was compared to the native OmniLog® PM analysis software. We consider the post-processing of the estimated parameters, the optimal classification of curve shapes and the detection of significant differences between them, as well as practically relevant questions such as detecting the impact of cultivation times and the minimum required number of experimental repeats. Conclusions We provide a comprehensive framework for data visualization and parameter estimation according to user choices. A flexible graphical representation strategy for displaying the results is proposed, including 95% confidence intervals for the estimated parameters. The spline approach is less prone to irregular curve shapes than fitting any of the considered models or using the native PM software for calculating both point estimates and confidence intervals. These can serve as a starting point for the automated post-processing of PM data, providing much more information than the strict dichotomization into positive and negative reactions. Our results form the basis for a freely available R package for the analysis of PM data. PMID:22536335
Software IV and V Research Priorities and Applied Program Accomplishments Within NASA
NASA Technical Reports Server (NTRS)
Blazy, Louis J.
2000-01-01
The mission of this research is to be world-class creators and facilitators of innovative, intelligent, high performance, reliable information technologies that enable NASA missions to (1) increase software safety and quality through error avoidance, early detection and resolution of errors, by utilizing and applying empirically based software engineering best practices; (2) ensure customer software risks are identified and/or that requirements are met and/or exceeded; (3) research, develop, apply, verify, and publish software technologies for competitive advantage and the advancement of science; and (4) facilitate the transfer of science and engineering data, methods, and practices to NASA, educational institutions, state agencies, and commercial organizations. The goals are to become a national Center Of Excellence (COE) in software and system independent verification and validation, and to become an international leading force in the field of software engineering for improving the safety, quality, reliability, and cost performance of software systems. This project addresses the following problems: Ensure safety of NASA missions, ensure requirements are met, minimize programmatic and technological risks of software development and operations, improve software quality, reduce costs and time to delivery, and improve the science of software engineering
Karampatos, Sarah; Papaioannou, Alexandra; Beattie, Karen A; Maly, Monica R; Chan, Adrian; Adachi, Jonathan D; Pritchard, Janet M
2016-04-01
Determine the reliability of a magnetic resonance (MR) image segmentation protocol for quantifying intramuscular adipose tissue (IntraMAT), subcutaneous adipose tissue, total muscle and intermuscular adipose tissue (InterMAT) of the lower leg. Ten axial lower leg MRI slices were obtained from 21 postmenopausal women using a 1 Tesla peripheral MRI system. Images were analyzed using sliceOmatic™ software. The average cross-sectional areas of the tissues were computed for the ten slices. Intra-rater and inter-rater reliability were determined and expressed as the standard error of measurement (SEM) (absolute reliability) and intraclass coefficient (ICC) (relative reliability). Intra-rater and inter-rater reliability for IntraMAT were 0.991 (95% confidence interval [CI] 0.978-0.996, p < 0.05) and 0.983 (95% CI 0.958-9.993, p < 0.05), respectively. For the other soft tissue compartments, the ICCs were all >0.90 (p < 0.05). The absolute intra-rater and inter-rater reliability (expressed as SEM) for segmenting IntraMAT were 22.19 mm(2) (95% CI 16.97-32.04) and 78.89 mm(2) (95% CI 60.36-113.92), respectively. This is a reliable segmentation protocol for quantifying IntraMAT and other soft-tissue compartments of the lower leg. A standard operating procedure manual is provided to assist users, and SEM values can be used to estimate sample size and determine confidence in repeated measurements in future research.
Software metrics: Software quality metrics for distributed systems. [reliability engineering
NASA Technical Reports Server (NTRS)
Post, J. V.
1981-01-01
Software quality metrics was extended to cover distributed computer systems. Emphasis is placed on studying embedded computer systems and on viewing them within a system life cycle. The hierarchy of quality factors, criteria, and metrics was maintained. New software quality factors were added, including survivability, expandability, and evolvability.
Modeling Student Software Testing Processes: Attitudes, Behaviors, Interventions, and Their Effects
ERIC Educational Resources Information Center
Buffardi, Kevin John
2014-01-01
Effective software testing identifies potential bugs and helps correct them, producing more reliable and maintainable software. As software development processes have evolved, incremental testing techniques have grown in popularity, particularly with introduction of test-driven development (TDD). However, many programmers struggle to adopt TDD's…
Reliability of Soft Tissue Model Based Implant Surgical Guides; A Methodological Mistake.
Sabour, Siamak; Dastjerdi, Elahe Vahid
2012-08-20
Abstract We were interested to read the paper by Maney P and colleagues published in the July 2012 issue of J Oral Implantol. The authors aimed to assess the reliability of soft tissue model based implant surgical guides reported that the accuracy was evaluated using software. 1 I found the manuscript title of Maney P, et al. incorrect and misleading. Moreover, they reported twenty-two sites (46.81%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). As the authors point out in their conclusion, Soft tissue models do not always provide sufficient accuracy for implant surgical guide fabrication.Reliability (precision) and validity (accuracy) are two different methodological issues in researches. Sensitivity, specificity, PPV, NPV, likelihood ratio positive (true positive/false negative) and likelihood ratio negative (false positive/ true negative) as well as odds ratio (true results\\false results - preferably more than 50) are among the tests to evaluate the validity (accuracy) of a single test compared to a gold standard.2-4 It is not clear that the reported twenty-two sites (46.81%) which were considered accurate related to which of the above mentioned estimates for validity analysis. Reliability (repeatability or reproducibility) is being assessed by different statistical tests such as Pearson r, least square and paired t.test which all of them are among common mistakes in reliability analysis 5. Briefly, for quantitative variable Intra Class Correlation Coefficient (ICC) and for qualitative variables weighted kappa should be used with caution because kappa has its own limitation too. Regarding reliability or agreement, it is good to know that for computing kappa value, just concordant cells are being considered, whereas discordant cells should also be taking into account in order to reach a correct estimation of agreement (Weighted kappa).2-4 As a take home message, for reliability and validity analysis, appropriate tests should be applied.
NASA Technical Reports Server (NTRS)
Trevino, Luis; Brown, Terry; Crumbley, R. T. (Technical Monitor)
2001-01-01
The problem to be addressed in this paper is to explore how the use of Soft Computing Technologies (SCT) could be employed to improve overall vehicle system safety, reliability, and rocket engine performance by development of a qualitative and reliable engine control system (QRECS). Specifically, this will be addressed by enhancing rocket engine control using SCT, innovative data mining tools, and sound software engineering practices used in Marshall's Flight Software Group (FSG). The principle goals for addressing the issue of quality are to improve software management, software development time, software maintenance, processor execution, fault tolerance and mitigation, and nonlinear control in power level transitions. The intent is not to discuss any shortcomings of existing engine control methodologies, but to provide alternative design choices for control, implementation, performance, and sustaining engineering, all relative to addressing the issue of reliability. The approaches outlined in this paper will require knowledge in the fields of rocket engine propulsion (system level), software engineering for embedded flight software systems, and soft computing technologies (i.e., neural networks, fuzzy logic, data mining, and Bayesian belief networks); some of which are briefed in this paper. For this effort, the targeted demonstration rocket engine testbed is the MC-1 engine (formerly FASTRAC) which is simulated with hardware and software in the Marshall Avionics & Software Testbed (MAST) laboratory that currently resides at NASA's Marshall Space Flight Center, building 4476, and is managed by the Avionics Department. A brief plan of action for design, development, implementation, and testing a Phase One effort for QRECS is given, along with expected results. Phase One will focus on development of a Smart Start Engine Module and a Mainstage Engine Module for proper engine start and mainstage engine operations. The overall intent is to demonstrate that by employing soft computing technologies, the quality and reliability of the overall scheme to engine controller development is further improved and vehicle safety is further insured. The final product that this paper proposes is an approach to development of an alternative low cost engine controller that would be capable of performing in unique vision spacecraft vehicles requiring low cost advanced avionics architectures for autonomous operations from engine pre-start to engine shutdown.
A general software reliability process simulation technique
NASA Technical Reports Server (NTRS)
Tausworthe, Robert C.
1991-01-01
The structure and rationale of the generalized software reliability process, together with the design and implementation of a computer program that simulates this process are described. Given assumed parameters of a particular project, the users of this program are able to generate simulated status timelines of work products, numbers of injected anomalies, and the progress of testing, fault isolation, repair, validation, and retest. Such timelines are useful in comparison with actual timeline data, for validating the project input parameters, and for providing data for researchers in reliability prediction modeling.
Rajyalakshmi, R.; Prakash, Winston D.; Ali, Mohammad Javed; Naik, Milind N.
2017-01-01
Purpose: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID) serves as a reliable scale for facial measurements. Methods: This study was a prospective, single-blind, comparative study. Two clinicians performed 12 periorbital measurements on 100 standardised face photographs. Each individual’s HVID was determined by Orbscan IIz and used as a scale for measurements using ImageJ software. All measurements were repeated using the ‘average’ HVID of the study population as a measurement scale. Intraclass correlation coefficient (ICC) and Pearson product-moment coefficient were used as statistical tests to analyse the data. Results: The range of ICC for intra- and interobserver variability was 0.79–0.99 and 0.86–0.99, respectively. Test-retest reliability ranged from 0.66–1.0 to 0.77–0.98, respectively. When average HVID of the study population was used as scale, ICC ranged from 0.83 to 0.99, and the test-retest reliability ranged from 0.83 to 0.96 and the measurements correlated well with recordings done with individual Orbscan HVID measurements. Conclusion: Periorbital biometric measurements using ImageJ software are reproducible and repeatable. Average HVID of the population as measured by Orbscan is a reliable scale for facial measurements. PMID:29403183
Lee, L.; Helsel, D.
2005-01-01
Trace contaminants in water, including metals and organics, often are measured at sufficiently low concentrations to be reported only as values below the instrument detection limit. Interpretation of these "less thans" is complicated when multiple detection limits occur. Statistical methods for multiply censored, or multiple-detection limit, datasets have been developed for medical and industrial statistics, and can be employed to estimate summary statistics or model the distributions of trace-level environmental data. We describe S-language-based software tools that perform robust linear regression on order statistics (ROS). The ROS method has been evaluated as one of the most reliable procedures for developing summary statistics of multiply censored data. It is applicable to any dataset that has 0 to 80% of its values censored. These tools are a part of a software library, or add-on package, for the R environment for statistical computing. This library can be used to generate ROS models and associated summary statistics, plot modeled distributions, and predict exceedance probabilities of water-quality standards. ?? 2005 Elsevier Ltd. All rights reserved.
Software Certification and Software Certificate Management Systems
NASA Technical Reports Server (NTRS)
Denney, Ewen; Fischer, Bernd
2005-01-01
Incremental certification and re-certification of code as it is developed and modified is a prerequisite for applying modem, evolutionary development processes, which are especially relevant for NASA. For example, the Columbia Accident Investigation Board (CAIB) report 121 concluded there is "the need for improved and uniform statistical sampling, audit, and certification processes". Also, re-certification time has been a limiting factor in making changes to Space Shuttle code close to launch time. This is likely to be an even bigger problem with the rapid turnaround required in developing NASA s replacement for the Space Shuttle, the Crew Exploration Vehicle (CEV). Hence, intelligent development processes are needed which place certification at the center of development. If certification tools provide useful information, such as estimated time and effort, they are more likely to be adopted. The ultimate impact of such a tool will be reduced effort and increased reliability.
Software reliability: Additional investigations into modeling with replicated experiments
NASA Technical Reports Server (NTRS)
Nagel, P. M.; Schotz, F. M.; Skirvan, J. A.
1984-01-01
The effects of programmer experience level, different program usage distributions, and programming languages are explored. All these factors affect performance, and some tentative relational hypotheses are presented. An analytic framework for replicated and non-replicated (traditional) software experiments is presented. A method of obtaining an upper bound on the error rate of the next error is proposed. The method was validated empirically by comparing forecasts with actual data. In all 14 cases the bound exceeded the observed parameter, albeit somewhat conservatively. Two other forecasting methods are proposed and compared to observed results. Although demonstrated relative to this framework that stages are neither independent nor exponentially distributed, empirical estimates show that the exponential assumption is nearly valid for all but the extreme tails of the distribution. Except for the dependence in the stage probabilities, Cox's model approximates to a degree what is being observed.
Rahnama, Leila; Rezasoltani, Asghar; Khalkhali-Zavieh, Minoo; Rahnama, Behnam; Noori-Kochi, Farhang
2015-01-01
OBJECTIVES: This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals. METHOD: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter-session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively. RESULTS: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects. CONCLUSIONS: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain. PMID:26443975
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Cameron W.; Granzow, Brian; Diamond, Gerrett
Unstructured mesh methods, like finite elements and finite volumes, support the effective analysis of complex physical behaviors modeled by partial differential equations over general threedimensional domains. The most reliable and efficient methods apply adaptive procedures with a-posteriori error estimators that indicate where and how the mesh is to be modified. Although adaptive meshes can have two to three orders of magnitude fewer elements than a more uniform mesh for the same level of accuracy, there are many complex simulations where the meshes required are so large that they can only be solved on massively parallel systems.
Smith, Cameron W.; Granzow, Brian; Diamond, Gerrett; ...
2017-01-01
Unstructured mesh methods, like finite elements and finite volumes, support the effective analysis of complex physical behaviors modeled by partial differential equations over general threedimensional domains. The most reliable and efficient methods apply adaptive procedures with a-posteriori error estimators that indicate where and how the mesh is to be modified. Although adaptive meshes can have two to three orders of magnitude fewer elements than a more uniform mesh for the same level of accuracy, there are many complex simulations where the meshes required are so large that they can only be solved on massively parallel systems.
Gage, R; Wilson, N; Signal, L; Barr, M; Mackay, C; Reeder, A; Thomson, G
2018-05-16
Shade in public spaces can lower the risk of and sun burning and skin cancer. However, existing methods of auditing shade require travel between sites, and sunny weather conditions. This study aimed to evaluate the feasibility of free computer software-Google Earth-for assessing shade in urban open spaces. A shade projection method was developed that uses Google Earth street view and aerial images to estimate shade at solar noon on the summer solstice, irrespective of the date of image capture. Three researchers used the method to separately estimate shade cover over pre-defined activity areas in a sample of 45 New Zealand urban open spaces, including 24 playgrounds, 12 beaches and 9 outdoor pools. Outcome measures included method accuracy (assessed by comparison with a subsample of field observations of 10 of the settings) and inter-rater reliability. Of the 164 activity areas identified in the 45 settings, most (83%) had no shade cover. The method identified most activity areas in playgrounds (85%) and beaches (93%) and was accurate for assessing shade over these areas (predictive values of 100%). Only 8% of activity areas at outdoor pools were identified, due to a lack of street view images. Reliability for shade cover estimates was excellent (intraclass correlation coefficient of 0.97, 95% CI 0.97-0.98). Google Earth appears to be a reasonably accurate and reliable and shade audit tool for playgrounds and beaches. The findings are relevant for programmes focused on supporting the development of healthy urban open spaces.
Mohammed, Rezwana Begum; Kalyan, V Siva; Tircouveluri, Saritha; Vegesna, Goutham Chakravarthy; Chirla, Anil; Varma, D Maruthi
2014-07-01
Determining the age of a person in the absence of documentary evidence of birth is essential for legal and medico-legal purpose. Fishman method of skeletal maturation is widely used for this purpose; however, the reliability of this method for people with all geographic locations is not well-established. In this study, we assessed various stages of carpal and metacarpal bone maturation and tested the reliability of Fishman method of skeletal maturation to estimate the age in South Indian population. We also evaluated the correlation between the chronological age (CA) and predicted age based on the Fishman method of skeletal maturation. Digital right hand-wrist radiographs of 330 individuals aged 9-20 years were obtained and the skeletal maturity stage for each subject was determined using Fishman method. The skeletal maturation indicator scores were obtained and analyzed with reference to CA and sex. Data was analyzed using the SPSS software package (version 12, SPSS Inc., Chicago, IL, USA). The study subjects had a tendency toward late maturation with the mean skeletal age (SA) estimated being significantly lowers (P < 0.05) than the mean CA at various skeletal maturity stages. Nevertheless, significant correlation was observed in this study between SA and CA for males (r = 0.82) and females (r = 0.85). Interestingly, female subjects were observed to be advanced in SA compared with males. Fishman method of skeletal maturation can be used as an alternative tool for the assessment of mean age of an individual of unknown CA in South Indian children.
Bonekamp, S; Ghosh, P; Crawford, S; Solga, S F; Horska, A; Brancati, F L; Diehl, A M; Smith, S; Clark, J M
2008-01-01
To examine five available software packages for the assessment of abdominal adipose tissue with magnetic resonance imaging, compare their features and assess the reliability of measurement results. Feature evaluation and test-retest reliability of softwares (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision) used in manual, semi-automated or automated segmentation of abdominal adipose tissue. A random sample of 15 obese adults with type 2 diabetes. Axial T1-weighted spin echo images centered at vertebral bodies of L2-L3 were acquired at 1.5 T. Five software packages were evaluated (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision), comparing manual, semi-automated and automated segmentation approaches. Images were segmented into cross-sectional area (CSA), and the areas of visceral (VAT) and subcutaneous adipose tissue (SAT). Ease of learning and use and the design of the graphical user interface (GUI) were rated. Intra-observer accuracy and agreement between the software packages were calculated using intra-class correlation. Intra-class correlation coefficient was used to obtain test-retest reliability. Three of the five evaluated programs offered a semi-automated technique to segment the images based on histogram values or a user-defined threshold. One software package allowed manual delineation only. One fully automated program demonstrated the drawbacks of uncritical automated processing. The semi-automated approaches reduced variability and measurement error, and improved reproducibility. There was no significant difference in the intra-observer agreement in SAT and CSA. The VAT measurements showed significantly lower test-retest reliability. There were some differences between the software packages in qualitative aspects, such as user friendliness. Four out of five packages provided essentially the same results with respect to the inter- and intra-rater reproducibility. Our results using SliceOmatic, Analyze or NIHImage were comparable and could be used interchangeably. Newly developed fully automated approaches should be compared to one of the examined software packages.
Bonekamp, S; Ghosh, P; Crawford, S; Solga, SF; Horska, A; Brancati, FL; Diehl, AM; Smith, S; Clark, JM
2009-01-01
Objective To examine five available software packages for the assessment of abdominal adipose tissue with magnetic resonance imaging, compare their features and assess the reliability of measurement results. Design Feature evaluation and test–retest reliability of softwares (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision) used in manual, semi-automated or automated segmentation of abdominal adipose tissue. Subjects A random sample of 15 obese adults with type 2 diabetes. Measurements Axial T1-weighted spin echo images centered at vertebral bodies of L2–L3 were acquired at 1.5 T. Five software packages were evaluated (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision), comparing manual, semi-automated and automated segmentation approaches. Images were segmented into cross-sectional area (CSA), and the areas of visceral (VAT) and subcutaneous adipose tissue (SAT). Ease of learning and use and the design of the graphical user interface (GUI) were rated. Intra-observer accuracy and agreement between the software packages were calculated using intra-class correlation. Intra-class correlation coefficient was used to obtain test–retest reliability. Results Three of the five evaluated programs offered a semi-automated technique to segment the images based on histogram values or a user-defined threshold. One software package allowed manual delineation only. One fully automated program demonstrated the drawbacks of uncritical automated processing. The semi-automated approaches reduced variability and measurement error, and improved reproducibility. There was no significant difference in the intra-observer agreement in SAT and CSA. The VAT measurements showed significantly lower test–retest reliability. There were some differences between the software packages in qualitative aspects, such as user friendliness. Conclusion Four out of five packages provided essentially the same results with respect to the inter- and intra-rater reproducibility. Our results using SliceOmatic, Analyze or NIHImage were comparable and could be used interchangeably. Newly developed fully automated approaches should be compared to one of the examined software packages. PMID:17700582
The cost of software fault tolerance
NASA Technical Reports Server (NTRS)
Migneault, G. E.
1982-01-01
The proposed use of software fault tolerance techniques as a means of reducing software costs in avionics and as a means of addressing the issue of system unreliability due to faults in software is examined. A model is developed to provide a view of the relationships among cost, redundancy, and reliability which suggests strategies for software development and maintenance which are not conventional.
ERIC Educational Resources Information Center
Lafferty, Mark T.
2010-01-01
The number of project failures and those projects completed over cost and over schedule has been a significant issue for software project managers. Among the many reasons for failure, inaccuracy in software estimation--the basis for project bidding, budgeting, planning, and probability estimates--has been identified as a root cause of a high…
Techniques and software tools for estimating ultrasonic signal-to-noise ratios
NASA Astrophysics Data System (ADS)
Chiou, Chien-Ping; Margetan, Frank J.; McKillip, Matthew; Engle, Brady J.; Roberts, Ronald A.
2016-02-01
At Iowa State University's Center for Nondestructive Evaluation (ISU CNDE), the use of models to simulate ultrasonic inspections has played a key role in R&D efforts for over 30 years. To this end a series of wave propagation models, flaw response models, and microstructural backscatter models have been developed to address inspection problems of interest. One use of the combined models is the estimation of signal-to-noise ratios (S/N) in circumstances where backscatter from the microstructure (grain noise) acts to mask sonic echoes from internal defects. Such S/N models have been used in the past to address questions of inspection optimization and reliability. Under the sponsorship of the National Science Foundation's Industry/University Cooperative Research Center at ISU, an effort was recently initiated to improve existing research-grade software by adding graphical user interface (GUI) to become user friendly tools for the rapid estimation of S/N for ultrasonic inspections of metals. The software combines: (1) a Python-based GUI for specifying an inspection scenario and displaying results; and (2) a Fortran-based engine for computing defect signal and backscattered grain noise characteristics. The latter makes use of several models including: the Multi-Gaussian Beam Model for computing sonic fields radiated by commercial transducers; the Thompson-Gray Model for the response from an internal defect; the Independent Scatterer Model for backscattered grain noise; and the Stanke-Kino Unified Model for attenuation. The initial emphasis was on reformulating the research-grade code into a suitable modular form, adding the graphical user interface and performing computations rapidly and robustly. Thus the initial inspection problem being addressed is relatively simple. A normal-incidence pulse/echo immersion inspection is simulated for a curved metal component having a non-uniform microstructure, specifically an equiaxed, untextured microstructure in which the average grain size may vary with depth. The defect may be a flat-bottomed-hole reference reflector, a spherical void or a spherical inclusion. In future generations of the software, microstructures and defect types will be generalized and oblique incidence inspections will be treated as well. This paper provides an overview of the modeling approach and presents illustrative results output by the first-generation software.
A Compatible Hardware/Software Reliability Prediction Model.
1981-07-22
machines. In particular, he was interested in the following problem: assu me that one has a collection of connected elements computing and transmitting...software reliability prediction model is desirable, the findings about the Weibull distribution are intriguing. After collecting failure data from several...capacitor, some of the added charge carriers are collected by the capacitor. If the added charge is sufficiently large, the information stored is changed
ERIC Educational Resources Information Center
Fitzgibbons, Megan; Meert, Deborah
2010-01-01
The use of bibliographic management software and its internal search interfaces is now pervasive among researchers. This study compares the results between searches conducted in academic databases' search interfaces versus the EndNote search interface. The results show mixed search reliability, depending on the database and type of search…
Structural Reliability Using Probability Density Estimation Methods Within NESSUS
NASA Technical Reports Server (NTRS)
Chamis, Chrisos C. (Technical Monitor); Godines, Cody Ric
2003-01-01
A reliability analysis studies a mathematical model of a physical system taking into account uncertainties of design variables and common results are estimations of a response density, which also implies estimations of its parameters. Some common density parameters include the mean value, the standard deviation, and specific percentile(s) of the response, which are measures of central tendency, variation, and probability regions, respectively. Reliability analyses are important since the results can lead to different designs by calculating the probability of observing safe responses in each of the proposed designs. All of this is done at the expense of added computational time as compared to a single deterministic analysis which will result in one value of the response out of many that make up the density of the response. Sampling methods, such as monte carlo (MC) and latin hypercube sampling (LHS), can be used to perform reliability analyses and can compute nonlinear response density parameters even if the response is dependent on many random variables. Hence, both methods are very robust; however, they are computationally expensive to use in the estimation of the response density parameters. Both methods are 2 of 13 stochastic methods that are contained within the Numerical Evaluation of Stochastic Structures Under Stress (NESSUS) program. NESSUS is a probabilistic finite element analysis (FEA) program that was developed through funding from NASA Glenn Research Center (GRC). It has the additional capability of being linked to other analysis programs; therefore, probabilistic fluid dynamics, fracture mechanics, and heat transfer are only a few of what is possible with this software. The LHS method is the newest addition to the stochastic methods within NESSUS. Part of this work was to enhance NESSUS with the LHS method. The new LHS module is complete, has been successfully integrated with NESSUS, and been used to study four different test cases that have been proposed by the Society of Automotive Engineers (SAE). The test cases compare different probabilistic methods within NESSUS because it is important that a user can have confidence that estimates of stochastic parameters of a response will be within an acceptable error limit. For each response, the mean, standard deviation, and 0.99 percentile, are repeatedly estimated which allows confidence statements to be made for each parameter estimated, and for each method. Thus, the ability of several stochastic methods to efficiently and accurately estimate density parameters is compared using four valid test cases. While all of the reliability methods used performed quite well, for the new LHS module within NESSUS it was found that it had a lower estimation error than MC when they were used to estimate the mean, standard deviation, and 0.99 percentile of the four different stochastic responses. Also, LHS required a smaller amount of calculations to obtain low error answers with a high amount of confidence than MC. It can therefore be stated that NESSUS is an important reliability tool that has a variety of sound probabilistic methods a user can employ and the newest LHS module is a valuable new enhancement of the program.
Blended Training on Scientific Software: A Study on How Scientific Data Are Generated
ERIC Educational Resources Information Center
Skordaki, Efrosyni-Maria; Bainbridge, Susan
2018-01-01
This paper presents the results of a research study on scientific software training in blended learning environments. The investigation focused on training approaches followed by scientific software users whose goal is the reliable application of such software. A key issue in current literature is the requirement for a theory-substantiated…
Increasing the reliability of ecological models using modern software engineering techniques
Robert M. Scheller; Brian R. Sturtevant; Eric J. Gustafson; Brendan C. Ward; David J. Mladenoff
2009-01-01
Modern software development techniques are largely unknown to ecologists. Typically, ecological models and other software tools are developed for limited research purposes, and additional capabilities are added later, usually in an ad hoc manner. Modern software engineering techniques can substantially increase scientific rigor and confidence in ecological models and...
NASA Technical Reports Server (NTRS)
Stefanski, Philip L.
2015-01-01
Commercially available software packages today allow users to quickly perform the routine evaluations of (1) descriptive statistics to numerically and graphically summarize both sample and population data, (2) inferential statistics that draws conclusions about a given population from samples taken of it, (3) probability determinations that can be used to generate estimates of reliability allowables, and finally (4) the setup of designed experiments and analysis of their data to identify significant material and process characteristics for application in both product manufacturing and performance enhancement. This paper presents examples of analysis and experimental design work that has been conducted using Statgraphics®(Registered Trademark) statistical software to obtain useful information with regard to solid rocket motor propellants and internal insulation material. Data were obtained from a number of programs (Shuttle, Constellation, and Space Launch System) and sources that include solid propellant burn rate strands, tensile specimens, sub-scale test motors, full-scale operational motors, rubber insulation specimens, and sub-scale rubber insulation analog samples. Besides facilitating the experimental design process to yield meaningful results, statistical software has demonstrated its ability to quickly perform complex data analyses and yield significant findings that might otherwise have gone unnoticed. One caveat to these successes is that useful results not only derive from the inherent power of the software package, but also from the skill and understanding of the data analyst.
Ozaki, Y.; Kaida, A.; Miura, M.; Nakagawa, K.; Toda, K.; Yoshimura, R.; Sumi, Y.; Kurabayashi, T.
2017-01-01
Abstract Early stage oral cancer can be cured with oral brachytherapy, but whole-body radiation exposure status has not been previously studied. Recently, the International Commission on Radiological Protection Committee (ICRP) recommended the use of ICRP phantoms to estimate radiation exposure from external and internal radiation sources. In this study, we used a Monte Carlo simulation with ICRP phantoms to estimate whole-body exposure from oral brachytherapy. We used a Particle and Heavy Ion Transport code System (PHITS) to model oral brachytherapy with 192Ir hairpins and 198Au grains and to perform a Monte Carlo simulation on the ICRP adult reference computational phantoms. To confirm the simulations, we also computed local dose distributions from these small sources, and compared them with the results from Oncentra manual Low Dose Rate Treatment Planning (mLDR) software which is used in day-to-day clinical practice. We successfully obtained data on absorbed dose for each organ in males and females. Sex-averaged equivalent doses were 0.547 and 0.710 Sv with 192Ir hairpins and 198Au grains, respectively. Simulation with PHITS was reliable when compared with an alternative computational technique using mLDR software. We concluded that the absorbed dose for each organ and whole-body exposure from oral brachytherapy can be estimated with Monte Carlo simulation using PHITS on ICRP reference phantoms. Effective doses for patients with oral cancer were obtained. PMID:28339846
Jain, Rajat; Omar, Mohamed; Chaparala, Hemant; Kahn, Adam; Li, Jianbo; Kahn, Leonard; Sivalingam, Sri
2018-04-23
To compare the accuracy and reliability of stone volume estimated by ellipsoid formula (EFv) and CT-based algorithm (CTv) to true volume (TV) by water displacement in an in vitro model. Ninety stone phantoms were created using clay (0.5-40 cm 3 , 814 HU ±91) and scanned with CT. For each stone, TV was measured by water displacement, CTv was calculated by the region-growing algorithm in the CT-based software AGFA IMPAX Volume Viewer, and EFv was calculated by the standard formula π × L × W × H × 0.167. All measurements were repeated thrice, and concordance correlation coefficient (CCC) was calculated for the whole group, as well as subgroups based on volume (<1.5 cm 3 , 1.5-6 cm 3 , and >6 cm 3 ). Mean TV, CTv, and EFv were 6.42 cm 3 ± 6.57 (range: 0.5-39.37 cm 3 ), 6.24 cm 3 ± 6.15 (0.48-36.1 cm 3 ), and 8.98 cm 3 ± 9.96 (0.49-47.05 cm 3 ), respectively. When comparing TV to CTv, CCC was 0.99 (95% confidence interval [CI]: 0.99-0.995), indicating excellent agreement, although TV was slightly underestimated at larger volumes. When comparing TV to EFv, CCC was 0.82 (95% CI: 0.78-0.86), indicating poor agreement. EFv tended to overestimate the TV, especially as stone volume increased beyond 1.5 cm 3 , and there was a significant spread between trials. An automated CT-based algorithm more accurately and reliably estimates stone volume than does the ellipsoid formula. While further research is necessary to validate stone volume as a surrogate for stone burden, CT-based algorithmic volume measurement of urinary stones is a promising technology.
Applications of computerized adaptive testing (CAT) to the assessment of headache impact.
Ware, John E; Kosinski, Mark; Bjorner, Jakob B; Bayliss, Martha S; Batenhorst, Alice; Dahlöf, Carl G H; Tepper, Stewart; Dowson, Andrew
2003-12-01
To evaluate the feasibility of computerized adaptive testing (CAT) and the reliability and validity of CAT-based estimates of headache impact scores in comparison with 'static' surveys. Responses to the 54-item Headache Impact Test (HIT) were re-analyzed for recent headache sufferers (n = 1016) who completed telephone interviews during the National Survey of Headache Impact (NSHI). Item response theory (IRT) calibrations and the computerized dynamic health assessment (DYNHA) software were used to simulate CAT assessments by selecting the most informative items for each person and estimating impact scores according to pre-set precision standards (CAT-HIT). Results were compared with IRT estimates based on all items (total-HIT), computerized 6-item dynamic estimates (CAT-HIT-6), and a developmental version of a 'static' 6-item form (HIT-6-D). Analyses focused on: respondent burden (survey length and administration time), score distributions ('ceiling' and 'floor' effects), reliability and standard errors, and clinical validity (diagnosis, level of severity). A random sample (n = 245) was re-assessed to test responsiveness. A second study (n = 1103) compared actual CAT surveys and an improved 'static' HIT-6 among current headache sufferers sampled on the Internet. Respondents completed measures from the first study and the generic SF-8 Health Survey; some (n = 540) were re-tested on the Internet after 2 weeks. In the first study, simulated CAT-HIT and total-HIT scores were highly correlated (r = 0.92) without 'ceiling' or 'floor' effects and with a substantial reduction (90.8%) in respondent burden. Six of the 54 items accounted for the great majority of item administrations (3603/5028, 77.6%). CAT-HIT reliability estimates were very high (0.975-0.992) in the range where 95% of respondents scored, and relative validity (RV) coefficients were high for diagnosis (RV = 0.87) and severity (RV = 0.89); patient-level classifications were accurate 91.3% for a diagnosis of migraine. For all three criteria of change, CAT-HIT scores were more responsive than all other measures. In the second study, estimates of respondent burden, item usage, reliability and clinical validity were replicated. The test-retest reliability of CAT-HIT was 0.79 and alternate forms coefficients ranged from 0.85 to 0.91. All correlations with the generic SF-8 were negative. CAT-based administrations of headache impact items achieved very large reductions in respondent burden without compromising validity for purposes of patient screening or monitoring changes in headache impact over time. IRT models and CAT-based dynamic health assessments warrant testing among patients with other conditions.
Toward improved peptide feature detection in quantitative proteomics using stable isotope labeling.
Nilse, Lars; Sigloch, Florian Christoph; Biniossek, Martin L; Schilling, Oliver
2015-08-01
Reliable detection of peptides in LC-MS data is a key algorithmic step in the analysis of quantitative proteomics experiments. While highly abundant peptides can be detected reliably by most modern software tools, there is much less agreement on medium and low-intensity peptides in a sample. The choice of software tools can have a big impact on the quantification of proteins, especially for proteins that appear in lower concentrations. However, in many experiments, it is precisely this region of less abundant but substantially regulated proteins that holds the biggest potential for discoveries. This is particularly true for discovery proteomics in the pharmacological sector with a specific interest in key regulatory proteins. In this viewpoint article, we discuss how the development of novel software algorithms allows us to study this region of the proteome with increased confidence. Reliable results are one of many aspects to be considered when deciding on a bioinformatics software platform. Deployment into existing IT infrastructures, compatibility with other software packages, scalability, automation, flexibility, and support need to be considered and are briefly addressed in this viewpoint article. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Wild, Christian; Eckhardt, Dave
1987-01-01
The development of a methodology for the production of highly reliable software is one of the greatest challenges facing the computer industry. Meeting this challenge will undoubtably involve the integration of many technologies. This paper describes the use of Artificial Intelligence technologies in the automated analysis of the formal algebraic specifications of abstract data types. These technologies include symbolic execution of specifications using techniques of automated deduction and machine learning through the use of examples. On-going research into the role of knowledge representation and problem solving in the process of developing software is also discussed.
Singendonk, M M J; Rosen, R; Oors, J; Rommel, N; van Wijk, M P; Benninga, M A; Nurko, S; Omari, T I
2017-11-01
Subtyping achalasia by high-resolution manometry (HRM) is clinically relevant as response to therapy and prognosis have shown to vary accordingly. The aim of this study was to assess inter- and intrarater reliability of diagnosing achalasia and achalasia subtyping in children using the Chicago Classification (CC) V3.0. Six observers analyzed 40 pediatric HRM recordings (22 achalasia and 18 non-achalasia) twice by using dedicated analysis software (ManoView 3.0, Given Imaging, Los Angeles, CA, USA). Integrated relaxation pressure (IRP4s), distal contractile integral (DCI), intrabolus pressurization pattern (IBP), and distal latency (DL) were extracted and analyzed hierarchically. Cohen's κ (2 raters) and Fleiss' κ (>2 raters) and the intraclass correlation coefficient (ICC) were used for categorical and ordinal data, respectively. Based on the results of dedicated analysis software only, intra- and interrater reliability was excellent and moderate (κ=0.89 and κ=0.52, respectively) for differentiating achalasia from non-achalasia. For subtyping achalasia, reliability decreased to substantial and fair (κ=0.72 and κ=0.28, respectively). When observers were allowed to change the software-driven diagnosis according to their own interpretation of the manometric patterns, intra- and interrater reliability increased for diagnosing achalasia (κ=0.98 and κ=0.92, respectively) and for subtyping achalasia (κ=0.79 and κ=0.58, respectively). Intra- and interrater agreement for diagnosing achalasia when using HRM and the CC was very good to excellent when results of automated analysis software were interpreted by experienced observers. More variability was seen when relying solely on the software-driven diagnosis and for subtyping achalasia. Therefore, diagnosing and subtyping achalasia should be performed in pediatric motility centers with significant expertise. © 2017 John Wiley & Sons Ltd.
Effect of system workload on operating system reliability - A study on IBM 3081
NASA Technical Reports Server (NTRS)
Iyer, R. K.; Rossetti, D. J.
1985-01-01
This paper presents an analysis of operating system failures on an IBM 3081 running VM/SP. Three broad categories of software failures are found: error handling, program control or logic, and hardware related; it is found that more than 25 percent of software failures occur in the hardware/software interface. Measurements show that results on software reliability cannot be considered representative unless the system workload is taken into account. The overall CPU execution rate, although measured to be close to 100 percent most of the time, is not found to correlate strongly with the occurrence of failures. Possible reasons for the observed workload failure dependency, based on detailed investigations of the failure data, are discussed.
Kim, Jinsuh; Leira, Enrique C; Callison, Richard C; Ludwig, Bryan; Moritani, Toshio; Magnotta, Vincent A; Madsen, Mark T
2010-05-01
We developed fully automated software for dynamic susceptibility contrast (DSC) MR perfusion-weighted imaging (PWI) to efficiently and reliably derive critical hemodynamic information for acute stroke treatment decisions. Brain MR PWI was performed in 80 consecutive patients with acute nonlacunar ischemic stroke within 24h after onset of symptom from January 2008 to August 2009. These studies were automatically processed to generate hemodynamic parameters that included cerebral blood flow and cerebral blood volume, and the mean transit time (MTT). To develop reliable software for PWI analysis, we used computationally robust algorithms including the piecewise continuous regression method to determine bolus arrival time (BAT), log-linear curve fitting, arrival time independent deconvolution method and sophisticated motion correction methods. An optimal arterial input function (AIF) search algorithm using a new artery-likelihood metric was also developed. Anatomical locations of the automatically determined AIF were reviewed and validated. The automatically computed BAT values were statistically compared with estimated BAT by a single observer. In addition, gamma-variate curve-fitting errors of AIF and inter-subject variability of AIFs were analyzed. Lastly, two observes independently assessed the quality and area of hypoperfusion mismatched with restricted diffusion area from motion corrected MTT maps and compared that with time-to-peak (TTP) maps using the standard approach. The AIF was identified within an arterial branch and enhanced areas of perfusion deficit were visualized in all evaluated cases. Total processing time was 10.9+/-2.5s (mean+/-s.d.) without motion correction and 267+/-80s (mean+/-s.d.) with motion correction on a standard personal computer. The MTT map produced with our software adequately estimated brain areas with perfusion deficit and was significantly less affected by random noise of the PWI when compared with the TTP map. Results of image quality assessment by two observers revealed that the MTT maps exhibited superior quality over the TTP maps (88% good rating of MTT as compared to 68% of TTP). Our software allowed fully automated deconvolution analysis of DSC PWI using proven efficient algorithms that can be applied to acute stroke treatment decisions. Our streamlined method also offers promise for further development of automated quantitative analysis of the ischemic penumbra. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.
Reliability of the Language ENvironment Analysis system (LENA™) in European French.
Canault, Mélanie; Le Normand, Marie-Thérèse; Foudil, Samy; Loundon, Natalie; Thai-Van, Hung
2016-09-01
In this study, we examined the accuracy of the Language ENvironment Analysis (LENA) system in European French. LENA is a digital recording device with software that facilitates the collection and analysis of audio recordings from young children, providing automated measures of the speech overheard and produced by the child. Eighteen native French-speaking children, who were divided into six age groups ranging from 3 to 48 months old, were recorded about 10-16 h per day, three days a week. A total of 324 samples (six 10-min chunks of recordings) were selected and then transcribed according to the CHAT format. Simple and mixed linear models between the LENA and human adult word count (AWC) and child vocalization count (CVC) estimates were performed, to determine to what extent the automatic and the human methods agreed. Both the AWC and CVC estimates were very reliable (r = .64 and .71, respectively) for the 324 samples. When controlling the random factors of participants and recordings, 1 h was sufficient to obtain a reliable sample. It was, however, found that two age groups (7-12 months and 13-18 months) had a significant effect on the AWC data and that the second day of recording had a significant effect on the CVC data. When noise-related factors were added to the model, only a significant effect of signal-to-noise ratio was found on the AWC data. All of these findings and their clinical implications are discussed, providing strong support for the reliability of LENA in French.
Asif, Muhammad Khan; Nambiar, Phrabhakaran; Mani, Shani Ann; Ibrahim, Norliza Binti; Khan, Iqra Muhammad; Sukumaran, Prema
2018-02-01
The methods of dental age estimation and identification of unknown deceased individuals are evolving with the introduction of advanced innovative imaging technologies in forensic investigations. However, assessing small structures like root canal volumes can be challenging in spite of using highly advanced technology. The aim of the study was to investigate which amongst the two methods of volumetric analysis of maxillary central incisors displayed higher strength of correlation between chronological age and pulp/tooth volume ratio for Malaysian adults. Volumetric analysis of pulp cavity/tooth ratio was employed in Method 1 and pulp chamber/crown ratio (up to cemento-enamel junction) was analysed in Method 2. The images were acquired employing CBCT scans and enhanced by manipulating them with the Mimics software. These scans belonged to 56 males and 54 females and their ages ranged from 16 to 65 years. Pearson correlation and regression analysis indicated that both methods used for volumetric measurements had strong correlation between chronological age and pulp/tooth volume ratio. However, Method 2 gave higher coefficient of determination value (R2 = 0.78) when compared to Method 1 (R2 = 0.64). Moreover, manipulation in Method 2 was less time consuming and revealed higher inter-examiner reliability (0.982) as no manual intervention during 'multiple slice editing phase' of the software was required. In conclusion, this study showed that volumetric analysis of pulp cavity/tooth ratio is a valuable gender independent technique and the Method 2 regression equation should be recommended for dental age estimation. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Data systems and computer science: Software Engineering Program
NASA Technical Reports Server (NTRS)
Zygielbaum, Arthur I.
1991-01-01
An external review of the Integrated Technology Plan for the Civil Space Program is presented. This review is specifically concerned with the Software Engineering Program. The goals of the Software Engineering Program are as follows: (1) improve NASA's ability to manage development, operation, and maintenance of complex software systems; (2) decrease NASA's cost and risk in engineering complex software systems; and (3) provide technology to assure safety and reliability of software in mission critical applications.
Automated face detection for occurrence and occupancy estimation in chimpanzees.
Crunchant, Anne-Sophie; Egerer, Monika; Loos, Alexander; Burghardt, Tilo; Zuberbühler, Klaus; Corogenes, Katherine; Leinert, Vera; Kulik, Lars; Kühl, Hjalmar S
2017-03-01
Surveying endangered species is necessary to evaluate conservation effectiveness. Camera trapping and biometric computer vision are recent technological advances. They have impacted on the methods applicable to field surveys and these methods have gained significant momentum over the last decade. Yet, most researchers inspect footage manually and few studies have used automated semantic processing of video trap data from the field. The particular aim of this study is to evaluate methods that incorporate automated face detection technology as an aid to estimate site use of two chimpanzee communities based on camera trapping. As a comparative baseline we employ traditional manual inspection of footage. Our analysis focuses specifically on the basic parameter of occurrence where we assess the performance and practical value of chimpanzee face detection software. We found that the semi-automated data processing required only 2-4% of the time compared to the purely manual analysis. This is a non-negligible increase in efficiency that is critical when assessing the feasibility of camera trap occupancy surveys. Our evaluations suggest that our methodology estimates the proportion of sites used relatively reliably. Chimpanzees are mostly detected when they are present and when videos are filmed in high-resolution: the highest recall rate was 77%, for a false alarm rate of 2.8% for videos containing only chimpanzee frontal face views. Certainly, our study is only a first step for transferring face detection software from the lab into field application. Our results are promising and indicate that the current limitation of detecting chimpanzees in camera trap footage due to lack of suitable face views can be easily overcome on the level of field data collection, that is, by the combined placement of multiple high-resolution cameras facing reverse directions. This will enable to routinely conduct chimpanzee occupancy surveys based on camera trapping and semi-automated processing of footage. Using semi-automated ape face detection technology for processing camera trap footage requires only 2-4% of the time compared to manual analysis and allows to estimate site use by chimpanzees relatively reliably. © 2017 Wiley Periodicals, Inc.
Geological modelling of mineral deposits for prediction in mining
NASA Astrophysics Data System (ADS)
Sides, E. J.
Accurate prediction of the shape, location, size and properties of the solid rock materials to be extracted during mining is essential for reliable technical and financial planning. This is achieved through geological modelling of the three-dimensional (3D) shape and properties of the materials present in mineral deposits, and the presentation of results in a form which is accessible to mine planning engineers. In recent years the application of interactive graphics software, offering 3D database handling, modelling and visualisation, has greatly enhanced the options available for predicting the subsurface limits and characteristics of mineral deposits. A review of conventional 3D geological interpretation methods, and the model struc- tures and modelling methods used in reserve estimation and mine planning software packages, illustrates the importance of such approaches in the modern mining industry. Despite the widespread introduction and acceptance of computer hardware and software in mining applications, in recent years, there has been little fundamental change in the way in which geology is used in orebody modelling for predictive purposes. Selected areas of current research, aimed at tackling issues such as the use of orientation data, quantification of morphological differences, incorporation of geological age relationships, multi-resolution models and the application of virtual reality hardware and software, are discussed.
Test Driven Development of a Parameterized Ice Sheet Component
NASA Astrophysics Data System (ADS)
Clune, T.
2011-12-01
Test driven development (TDD) is a software development methodology that offers many advantages over traditional approaches including reduced development and maintenance costs, improved reliability, and superior design quality. Although TDD is widely accepted in many software communities, the suitability to scientific software is largely undemonstrated and warrants a degree of skepticism. Indeed, numerical algorithms pose several challenges to unit testing in general, and TDD in particular. Among these challenges are the need to have simple, non-redundant closed-form expressions to compare against the results obtained from the implementation as well as realistic error estimates. The necessity for serial and parallel performance raises additional concerns for many scientific applicaitons. In previous work I demonstrated that TDD performed well for the development of a relatively simple numerical model that simulates the growth of snowflakes, but the results were anecdotal and of limited relevance to far more complex software components typical of climate models. This investigation has now been extended by successfully applying TDD to the implementation of a substantial portion of a new parameterized ice sheet component within a full climate model. After a brief introduction to TDD, I will present techniques that address some of the obstacles encountered with numerical algorithms. I will conclude with some quantitative and qualitative comparisons against climate components developed in a more traditional manner.
Availability Estimation for Facilities in Extreme Geographical Locations
NASA Technical Reports Server (NTRS)
Fischer, Gerd M.; Omotoso, Oluseun; Chen, Guangming; Evans, John W.
2012-01-01
A value added analysis for the Reliability. Availability and Maintainability of McMurdo Ground Station was developed, which will be a useful tool for system managers in sparing, maintenance planning and determining vital performance metrics needed for readiness assessment of the upgrades to the McMurdo System. Output of this study can also be used as inputs and recommendations for the application of Reliability Centered Maintenance (RCM) for the system. ReliaSoft's BlockSim. a commercial Reliability Analysis software package, has been used to model the availability of the system upgrade to the National Aeronautics and Space Administration (NASA) Near Earth Network (NEN) Ground Station at McMurdo Station in the Antarctica. The logistics challenges due to the closure of access to McMurdo Station during the Antarctic winter was modeled using a weighted composite of four Weibull distributions. one of the possible choices for statistical distributions throughout the software program and usually used to account for failure rates of components supplied by different manufacturers. The inaccessibility of the antenna site on a hill outside McMurdo Station throughout one year due to severe weather was modeled with a Weibull distribution for the repair crew availability. The Weibull distribution is based on an analysis of the available weather data for the antenna site for 2007 in combination with the rules for travel restrictions due to severe weather imposed by the administrating agency, the National Science Foundation (NSF). The simulations resulted in an upper bound for the system availability and allowed for identification of components that would improve availability based on a higher on-site spare count than initially planned.
Vispoel, Walter P; Morris, Carrie A; Kilinc, Murat
2018-01-01
We applied a new approach to Generalizability theory (G-theory) involving parallel splits and repeated measures to evaluate common uses of the Paulhus Deception Scales based on polytomous and four types of dichotomous scoring. G-theory indices of reliability and validity accounting for specific-factor, transient, and random-response measurement error supported use of polytomous over dichotomous scores as contamination checks; as control, explanatory, and outcome variables; as aspects of construct validation; and as indexes of environmental effects on socially desirable responding. Polytomous scoring also provided results for flagging faking as dependable as those when using dichotomous scoring methods. These findings argue strongly against the nearly exclusive use of dichotomous scoring for the Paulhus Deception Scales in practice and underscore the value of G-theory in demonstrating this. We provide guidelines for applying our G-theory techniques to other objectively scored clinical assessments, for using G-theory to estimate how changes to a measure might improve reliability, and for obtaining software to conduct G-theory analyses free of charge.
Reliability and Validity of the Footprint Assessment Method Using Photoshop CS5 Software.
Gutiérrez-Vilahú, Lourdes; Massó-Ortigosa, Núria; Costa-Tutusaus, Lluís; Guerra-Balic, Myriam
2015-05-01
Several sophisticated methods of footprint analysis currently exist. However, it is sometimes useful to apply standard measurement methods of recognized evidence with an easy and quick application. We sought to assess the reliability and validity of a new method of footprint assessment in a healthy population using Photoshop CS5 software (Adobe Systems Inc, San Jose, California). Forty-two footprints, corresponding to 21 healthy individuals (11 men with a mean ± SD age of 20.45 ± 2.16 years and 10 women with a mean ± SD age of 20.00 ± 1.70 years) were analyzed. Footprints were recorded in static bipedal standing position using optical podography and digital photography. Three trials for each participant were performed. The Hernández-Corvo, Chippaux-Smirak, and Staheli indices and the Clarke angle were calculated by manual method and by computerized method using Photoshop CS5 software. Test-retest was used to determine reliability. Validity was obtained by intraclass correlation coefficient (ICC). The reliability test for all of the indices showed high values (ICC, 0.98-0.99). Moreover, the validity test clearly showed no difference between techniques (ICC, 0.99-1). The reliability and validity of a method to measure, assess, and record the podometric indices using Photoshop CS5 software has been demonstrated. This provides a quick and accurate tool useful for the digital recording of morphostatic foot study parameters and their control.
Software Size Estimation Using Expert Estimation: A Fuzzy Logic Approach
ERIC Educational Resources Information Center
Stevenson, Glenn A.
2012-01-01
For decades software managers have been using formal methodologies such as the Constructive Cost Model and Function Points to estimate the effort of software projects during the early stages of project development. While some research shows these methodologies to be effective, many software managers feel that they are overly complicated to use and…
Fault tolerant software modules for SIFT
NASA Technical Reports Server (NTRS)
Hecht, M.; Hecht, H.
1982-01-01
The implementation of software fault tolerance is investigated for critical modules of the Software Implemented Fault Tolerance (SIFT) operating system to support the computational and reliability requirements of advanced fly by wire transport aircraft. Fault tolerant designs generated for the error reported and global executive are examined. A description of the alternate routines, implementation requirements, and software validation are included.
Jiřík, Miroslav; Bartoš, Martin; Tomášek, Petr; Malečková, Anna; Kural, Tomáš; Horáková, Jana; Lukáš, David; Suchý, Tomáš; Kochová, Petra; Hubálek Kalbáčová, Marie; Králíčková, Milena; Tonar, Zbyněk
2018-06-01
Quantification of the structure and composition of biomaterials using micro-CT requires image segmentation due to the low contrast and overlapping radioopacity of biological materials. The amount of bias introduced by segmentation procedures is generally unknown. We aim to develop software that generates three-dimensional models of fibrous and porous structures with known volumes, surfaces, lengths, and object counts in fibrous materials and to provide a software tool that calibrates quantitative micro-CT assessments. Virtual image stacks were generated using the newly developed software TeIGen, enabling the simulation of micro-CT scans of unconnected tubes, connected tubes, and porosities. A realistic noise generator was incorporated. Forty image stacks were evaluated using micro-CT, and the error between the true known and estimated data was quantified. Starting with geometric primitives, the error of the numerical estimation of surfaces and volumes was eliminated, thereby enabling the quantification of volumes and surfaces of colliding objects. Analysis of the sensitivity of the thresholding upon parameters of generated testing image sets revealed the effects of decreasing resolution and increasing noise on the accuracy of the micro-CT quantification. The size of the error increased with decreasing resolution when the voxel size exceeded 1/10 of the typical object size, which simulated the effect of the smallest details that could still be reliably quantified. Open-source software for calibrating quantitative micro-CT assessments by producing and saving virtually generated image data sets with known morphometric data was made freely available to researchers involved in morphometry of three-dimensional fibrillar and porous structures in micro-CT scans. © 2018 Wiley Periodicals, Inc.
The Validation of a Software Evaluation Instrument.
ERIC Educational Resources Information Center
Schmitt, Dorren Rafael
This study, conducted at six southern universities, analyzed the validity and reliability of a researcher developed instrument designed to evaluate educational software in secondary mathematics. The instrument called the Instrument for Software Evaluation for Educators uses measurement scales, presents a summary section of the evaluation, and…
NASA Technical Reports Server (NTRS)
McNeill, Justin
1995-01-01
The Multimission Image Processing Subsystem (MIPS) at the Jet Propulsion Laboratory (JPL) has managed transitions of application software sets from one operating system and hardware platform to multiple operating systems and hardware platforms. As a part of these transitions, cost estimates were generated from the personal experience of in-house developers and managers to calculate the total effort required for such projects. Productivity measures have been collected for two such transitions, one very large and the other relatively small in terms of source lines of code. These estimates used a cost estimation model similar to the Software Engineering Laboratory (SEL) Effort Estimation Model. Experience in transitioning software within JPL MIPS have uncovered a high incidence of interface complexity. Interfaces, both internal and external to individual software applications, have contributed to software transition project complexity, and thus to scheduling difficulties and larger than anticipated design work on software to be ported.
NASA Astrophysics Data System (ADS)
Bouroubi, Mohamed Yacine
Multi-spectral satellite imagery, especially at high spatial resolution (finer than 30 m on the ground), represents an invaluable source of information for decision making in various domains in connection with natural resources management, environment preservation or urban planning and management. The mapping scales may range from local (finer resolution than 5 m) to regional (resolution coarser than 5m). The images are characterized by objects reflectance in the electromagnetic spectrum witch represents the key information in many applications. However, satellite sensor measurements are also affected by parasite input due to illumination and observation conditions, to the atmosphere, to topography and to sensor properties. Two questions have oriented this research. What is the best approach to retrieve surface reflectance with the measured values while taking into account these parasite factors? Is this retrieval a sine qua non condition for reliable image information extraction for the diverse domains of application for the images (mapping, environmental monitoring, landscape change detection, resources inventory, etc.)? The goals we have delineated for this research are as follow: (1) Develop software to retrieve ground reflectance while taking into account the aspects mentioned earlier. This software had to be modular enough to allow improvement and adaptation to diverse remote sensing application problems; and (2) Apply this software in various context (urban, agricultural, forest) and analyse results to evaluate the accuracy gain of extracted information from remote sensing imagery transformed in ground reflectance images to demonstrate the necessity of operating in this way, whatever the type of application. During this research, we have developed a tool to retrieve ground reflectance (the new version of the REFLECT software). This software is based on the formulas (and routines) of the 6S code (Second Simulation of Satellite Signal in the Solar Spectrum) and on the dark targets method to estimated the aerosol optical thickness, representing the most difficult factor to correct. Substantial improvements have been made to the existing models. These improvements essentially concern the aerosols properties (integration of a more recent model, improvement of the dark targets selection to estimate the AOD), the adjacency effect, the adaptation to most used high resolution (Landsat TM and ETM+, all HR SPOT 1 to 5, EO-1 ALI and ASTER) and very high resolution (QuickBird et Ikonos) sensors and the correction of topographic effects with a model that separate direct and diffuse solar radiation components and the adaptation of this model to forest canopy. Validation has shown that ground reflectance estimation with REFLECT is performed with an accuracy of approximately +/-0.01 in reflectance units (for in the visible, near-infrared and middle-infrared spectral bands) even for a surface with varying topography. This software has allowed demonstrating, through apparent reflectance simulations, how much parasite factors influencing numerical values of the images may alter the ground reflectance (errors ranging from 10 to 50%). REFLECT has also been used to examine the usefulness of ground reflectance instead of raw data for various common remote sensing applications in domains such as classification, change detection, agriculture and forestry. In most applications (multi-temporal change monitoring, use of vegetation indices, biophysical parameters estimation, etc.) image correction is a crucial step to obtain reliable results. From the computer environment standpoint, REFLECT is organized as a series of menus, corresponding to different steps of: input parameters introducing, gas transmittances calculation, AOD estimation, and finally image correction application, with the possibility of using the fast option witch process an image of 5000 by 5000 pixels in approximately 15 minutes. (Abstract shortened by UMI.)
Genomic prediction using imputed whole-genome sequence data in Holstein Friesian cattle.
van Binsbergen, Rianne; Calus, Mario P L; Bink, Marco C A M; van Eeuwijk, Fred A; Schrooten, Chris; Veerkamp, Roel F
2015-09-17
In contrast to currently used single nucleotide polymorphism (SNP) panels, the use of whole-genome sequence data is expected to enable the direct estimation of the effects of causal mutations on a given trait. This could lead to higher reliabilities of genomic predictions compared to those based on SNP genotypes. Also, at each generation of selection, recombination events between a SNP and a mutation can cause decay in reliability of genomic predictions based on markers rather than on the causal variants. Our objective was to investigate the use of imputed whole-genome sequence genotypes versus high-density SNP genotypes on (the persistency of) the reliability of genomic predictions using real cattle data. Highly accurate phenotypes based on daughter performance and Illumina BovineHD Beadchip genotypes were available for 5503 Holstein Friesian bulls. The BovineHD genotypes (631,428 SNPs) of each bull were used to impute whole-genome sequence genotypes (12,590,056 SNPs) using the Beagle software. Imputation was done using a multi-breed reference panel of 429 sequenced individuals. Genomic estimated breeding values for three traits were predicted using a Bayesian stochastic search variable selection (BSSVS) model and a genome-enabled best linear unbiased prediction model (GBLUP). Reliabilities of predictions were based on 2087 validation bulls, while the other 3416 bulls were used for training. Prediction reliabilities ranged from 0.37 to 0.52. BSSVS performed better than GBLUP in all cases. Reliabilities of genomic predictions were slightly lower with imputed sequence data than with BovineHD chip data. Also, the reliabilities tended to be lower for both sequence data and BovineHD chip data when relationships between training animals were low. No increase in persistency of prediction reliability using imputed sequence data was observed. Compared to BovineHD genotype data, using imputed sequence data for genomic prediction produced no advantage. To investigate the putative advantage of genomic prediction using (imputed) sequence data, a training set with a larger number of individuals that are distantly related to each other and genomic prediction models that incorporate biological information on the SNPs or that apply stricter SNP pre-selection should be considered.
Big Software for SmallSats: Adapting cFS to CubeSat Missions
NASA Technical Reports Server (NTRS)
Cudmore, Alan P.; Crum, Gary Alex; Sheikh, Salman; Marshall, James
2015-01-01
Expanding capabilities and mission objectives for SmallSats and CubeSats is driving the need for reliable, reusable, and robust flight software. While missions are becoming more complicated and the scientific goals more ambitious, the level of acceptable risk has decreased. Design challenges are further compounded by budget and schedule constraints that have not kept pace. NASA's Core Flight Software System (cFS) is an open source solution which enables teams to build flagship satellite level flight software within a CubeSat schedule and budget. NASA originally developed cFS to reduce mission and schedule risk for flagship satellite missions by increasing code reuse and reliability. The Lunar Reconnaissance Orbiter, which launched in 2009, was the first of a growing list of Class B rated missions to use cFS.
Development of an Environment for Software Reliability Model Selection
1992-09-01
now is directed to other related problems such as tools for model selection, multiversion programming, and software fault tolerance modeling... multiversion programming, 7. Hlardware can be repaired by spare modules, which is not. the case for software, 2-6 N. Preventive maintenance is very important
A Course in Real-Time Embedded Software
ERIC Educational Resources Information Center
Archibald, J. K.; Fife, W. S.
2007-01-01
Embedded systems are increasingly pervasive, and the creation of reliable controlling software offers unique challenges. Embedded software must interact directly with hardware, it must respond to events in a time-critical fashion, and it typically employs concurrency to meet response time requirements. This paper describes an innovative course…
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Novack, Steven D.; Hatfield, Glen S.; Britton, Paul
2017-01-01
Today's launch vehicles complex electronic and avionic systems heavily utilize the Field Programmable Gate Array (FPGA) integrated circuit (IC). FPGAs are prevalent ICs in communication protocols such as MIL-STD-1553B, and in control signal commands such as in solenoid/servo valves actuations. This paper will demonstrate guidelines to estimate FPGA failure rates for a launch vehicle, the guidelines will account for hardware, firmware, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC, FPGA memory and clock. The firmware portion will provide guidelines on the high level FPGA programming language and ways to account for software/code reliability growth. The radiation portion will provide guidelines on environment susceptibility as well as guidelines on tailoring other launch vehicle programs historical data to a specific launch vehicle.
Surface Temperature Data Analysis
NASA Technical Reports Server (NTRS)
Hansen, James; Ruedy, Reto
2012-01-01
Small global mean temperature changes may have significant to disastrous consequences for the Earth's climate if they persist for an extended period. Obtaining global means from local weather reports is hampered by the uneven spatial distribution of the reliably reporting weather stations. Methods had to be developed that minimize as far as possible the impact of that situation. This software is a method of combining temperature data of individual stations to obtain a global mean trend, overcoming/estimating the uncertainty introduced by the spatial and temporal gaps in the available data. Useful estimates were obtained by the introduction of a special grid, subdividing the Earth's surface into 8,000 equal-area boxes, using the existing data to create virtual stations at the center of each of these boxes, and combining temperature anomalies (after assessing the radius of high correlation) rather than temperatures.
Ask Pete, software planning and estimation through project characterization
NASA Technical Reports Server (NTRS)
Kurtz, T.
2001-01-01
Ask Pete, was developed by NASA to provide a tool for integrating the estimation and planning activities for a software development effort. It incorporates COCOMO II estimating with NASA's software development practices and IV&V criteria to characterize a project. This characterization is then used to generate estimates and tailored planning documents.
ERIC Educational Resources Information Center
National Academy of Sciences - National Research Council, Washington, DC.
The Panel on Guidelines for Statistical Software was organized in 1990 to document, assess, and prioritize problem areas regarding quality and reliability of statistical software; present prototype guidelines in high priority areas; and make recommendations for further research and discussion. This document provides the following papers presented…
Research of real-time communication software
NASA Astrophysics Data System (ADS)
Li, Maotang; Guo, Jingbo; Liu, Yuzhong; Li, Jiahong
2003-11-01
Real-time communication has been playing an increasingly important role in our work, life and ocean monitor. With the rapid progress of computer and communication technique as well as the miniaturization of communication system, it is needed to develop the adaptable and reliable real-time communication software in the ocean monitor system. This paper involves the real-time communication software research based on the point-to-point satellite intercommunication system. The object-oriented design method is adopted, which can transmit and receive video data and audio data as well as engineering data by satellite channel. In the real-time communication software, some software modules are developed, which can realize the point-to-point satellite intercommunication in the ocean monitor system. There are three advantages for the real-time communication software. One is that the real-time communication software increases the reliability of the point-to-point satellite intercommunication system working. Second is that some optional parameters are intercalated, which greatly increases the flexibility of the system working. Third is that some hardware is substituted by the real-time communication software, which not only decrease the expense of the system and promotes the miniaturization of communication system, but also aggrandizes the agility of the system.
NASA Astrophysics Data System (ADS)
Saini, K. K.; Sehgal, R. K.; Sethi, B. L.
2008-10-01
In this paper major reliability estimators are analyzed and there comparatively result are discussed. There strengths and weaknesses are evaluated in this case study. Each of the reliability estimators has certain advantages and disadvantages. Inter-rater reliability is one of the best ways to estimate reliability when your measure is an observation. However, it requires multiple raters or observers. As an alternative, you could look at the correlation of ratings of the same single observer repeated on two different occasions. Each of the reliability estimators will give a different value for reliability. In general, the test-retest and inter-rater reliability estimates will be lower in value than the parallel forms and internal consistency ones because they involve measuring at different times or with different raters. Since reliability estimates are often used in statistical analyses of quasi-experimental designs.
Scheerans, Christian; Derendorf, Hartmut; Kloft, Charlotte
2008-04-01
The area under the plasma concentration-time curve from time zero to infinity (AUC(0-inf)) is generally considered to be the most appropriate measure of total drug exposure for bioavailability/bioequivalence studies of orally administered drugs. However, the lack of a standardised method for identifying the mono-exponential terminal phase of the concentration-time curve causes variability for the estimated AUC(0-inf). The present investigation introduces a simple method, called the two times t(max) method (TTT method) to reliably identify the mono-exponential terminal phase in the case of oral administration. The new method was tested by Monte Carlo simulation in Excel and compared with the adjusted r squared algorithm (ARS algorithm) frequently used in pharmacokinetic software programs. Statistical diagnostics of three different scenarios, each with 10,000 hypothetical patients showed that the new method provided unbiased average AUC(0-inf) estimates for orally administered drugs with a monophasic concentration-time curve post maximum concentration. In addition, the TTT method generally provided more precise estimates for AUC(0-inf) compared with the ARS algorithm. It was concluded that the TTT method is a most reasonable tool to be used as a standardised method in pharmacokinetic analysis especially bioequivalence studies to reliably identify the mono-exponential terminal phase for orally administered drugs showing a monophasic concentration-time profile.
SAGA: A project to automate the management of software production systems
NASA Technical Reports Server (NTRS)
Campbell, Roy H.; Beckman-Davies, C. S.; Benzinger, L.; Beshers, G.; Laliberte, D.; Render, H.; Sum, R.; Smith, W.; Terwilliger, R.
1986-01-01
Research into software development is required to reduce its production cost and to improve its quality. Modern software systems, such as the embedded software required for NASA's space station initiative, stretch current software engineering techniques. The requirements to build large, reliable, and maintainable software systems increases with time. Much theoretical and practical research is in progress to improve software engineering techniques. One such technique is to build a software system or environment which directly supports the software engineering process, i.e., the SAGA project, comprising the research necessary to design and build a software development which automates the software engineering process. Progress under SAGA is described.
Health management and controls for Earth-to-orbit propulsion systems
NASA Astrophysics Data System (ADS)
Bickford, R. L.
1995-03-01
Avionics and health management technologies increase the safety and reliability while decreasing the overall cost for Earth-to-orbit (ETO) propulsion systems. New ETO propulsion systems will depend on highly reliable fault tolerant flight avionics, advanced sensing systems and artificial intelligence aided software to ensure critical control, safety and maintenance requirements are met in a cost effective manner. Propulsion avionics consist of the engine controller, actuators, sensors, software and ground support elements. In addition to control and safety functions, these elements perform system monitoring for health management. Health management is enhanced by advanced sensing systems and algorithms which provide automated fault detection and enable adaptive control and/or maintenance approaches. Aerojet is developing advanced fault tolerant rocket engine controllers which provide very high levels of reliability. Smart sensors and software systems which significantly enhance fault coverage and enable automated operations are also under development. Smart sensing systems, such as flight capable plume spectrometers, have reached maturity in ground-based applications and are suitable for bridging to flight. Software to detect failed sensors has reached similar maturity. This paper will discuss fault detection and isolation for advanced rocket engine controllers as well as examples of advanced sensing systems and software which significantly improve component failure detection for engine system safety and health management.
Lower Bounds to the Reliabilities of Factor Score Estimators.
Hessen, David J
2016-10-06
Under the general common factor model, the reliabilities of factor score estimators might be of more interest than the reliability of the total score (the unweighted sum of item scores). In this paper, lower bounds to the reliabilities of Thurstone's factor score estimators, Bartlett's factor score estimators, and McDonald's factor score estimators are derived and conditions are given under which these lower bounds are equal. The relative performance of the derived lower bounds is studied using classic example data sets. The results show that estimates of the lower bounds to the reliabilities of Thurstone's factor score estimators are greater than or equal to the estimates of the lower bounds to the reliabilities of Bartlett's and McDonald's factor score estimators.
Mohammed, Rezwana Begum; Kalyan, V. Siva; Tircouveluri, Saritha; Vegesna, Goutham Chakravarthy; Chirla, Anil; Varma, D. Maruthi
2014-01-01
Introduction: Determining the age of a person in the absence of documentary evidence of birth is essential for legal and medico-legal purpose. Fishman method of skeletal maturation is widely used for this purpose; however, the reliability of this method for people with all geographic locations is not well-established. Aims and Objectives: In this study, we assessed various stages of carpal and metacarpal bone maturation and tested the reliability of Fishman method of skeletal maturation to estimate the age in South Indian population. We also evaluated the correlation between the chronological age (CA) and predicted age based on the Fishman method of skeletal maturation. Materials and Methods: Digital right hand-wrist radiographs of 330 individuals aged 9-20 years were obtained and the skeletal maturity stage for each subject was determined using Fishman method. The skeletal maturation indicator scores were obtained and analyzed with reference to CA and sex. Data was analyzed using the SPSS software package (version 12, SPSS Inc., Chicago, IL, USA). Results: The study subjects had a tendency toward late maturation with the mean skeletal age (SA) estimated being significantly lowers (P < 0.05) than the mean CA at various skeletal maturity stages. Nevertheless, significant correlation was observed in this study between SA and CA for males (r = 0.82) and females (r = 0.85). Interestingly, female subjects were observed to be advanced in SA compared with males. Conclusion: Fishman method of skeletal maturation can be used as an alternative tool for the assessment of mean age of an individual of unknown CA in South Indian children. PMID:25097402
Nouri, Mahtab; Hamidiaval, Shadi; Akbarzadeh Baghban, Alireza; Basafa, Mohammad; Fahim, Mohammad
2015-01-01
Cephalometric norms of McNamara analysis have been studied in various populations due to their optimal efficiency. Dolphin cephalometric software greatly enhances the conduction of this analysis for orthodontic measurements. However, Dolphin is very expensive and cannot be afforded by many clinicians in developing countries. A suitable alternative software program in Farsi/English will greatly help Farsi speaking clinicians. The present study aimed to develop an affordable Iranian cephalometric analysis software program and compare it with Dolphin, the standard software available on the market for cephalometric analysis. In this diagnostic, descriptive study, 150 lateral cephalograms of normal occlusion individuals were selected in Mashhad and Qazvin, two major cities of Iran mainly populated with Fars ethnicity, the main Iranian ethnic group. After tracing the cephalograms, the McNamara analysis standards were measured both with Dolphin and the new software. The cephalometric software was designed using Microsoft Visual C++ program in Windows XP. Measurements made with the new software were compared with those of Dolphin software on both series of cephalograms. The validity and reliability were tested using intra-class correlation coefficient. Calculations showed a very high correlation between the results of the Iranian cephalometric analysis software and Dolphin. This confirms the validity and optimal efficacy of the newly designed software (ICC 0.570-1.0). According to our results, the newly designed software has acceptable validity and reliability and can be used for orthodontic diagnosis, treatment planning and assessment of treatment outcome.
1986-02-01
ionospheric sensing 118 I device, provide more reliable comnunications, especially when HF propagation is uncertain, by determining which frequencies...the Fleet Numerical Oceanography Center computer systems. GDEM generates a sound velocity profile from the surface to the sea floor at every 1/2...degrees of lat/log for the Northern Hemisphere oceans. GDEM is a Navy standard data base for all acoustic models. 18) Software Improvement Plan (SIP) as 600
Toward Dietary Assessment via Mobile Phone Video Cameras.
Chen, Nicholas; Lee, Yun Young; Rabb, Maurice; Schatz, Bruce
2010-11-13
Reliable dietary assessment is a challenging yet essential task for determining general health. Existing efforts are manual, require considerable effort, and are prone to underestimation and misrepresentation of food intake. We propose leveraging mobile phones to make this process faster, easier and automatic. Using mobile phones with built-in video cameras, individuals capture short videos of their meals; our software then automatically analyzes the videos to recognize dishes and estimate calories. Preliminary experiments on 20 typical dishes from a local cafeteria show promising results. Our approach complements existing dietary assessment methods to help individuals better manage their diet to prevent obesity and other diet-related diseases.
Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert
2011-05-20
Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and ≤5.3° for the sacral angles. The variability in the linear measurements (distances) was <4 mm. The variance of the measures was 1.7 and 2.6 times greater, respectively, for the angular and linear measures between the inter- and intrameasurer reliability. The image quality positively influenced the intermeasurer reliability especially for the proximal thoracic Cobb angle, T10-L2 lordosis, sacral slope and L5 seating. The accuracy study revealed that on average the difference in the angular measures was < 2° for the Cobb angles, and < 4° for the other angles, except T2-T12 kyphosis (5.3°). The linear measures were all <3.5 mm difference on average. The majority of the measures, which were analyzed in this study demonstrated good to excellent reliability and accuracy. The novel semiautomatic measurement software can be recommended for use for clinical, research or multicenter study purposes.
Reliable and Fault-Tolerant Software-Defined Network Operations Scheme for Remote 3D Printing
NASA Astrophysics Data System (ADS)
Kim, Dongkyun; Gil, Joon-Min
2015-03-01
The recent wide expansion of applicable three-dimensional (3D) printing and software-defined networking (SDN) technologies has led to a great deal of attention being focused on efficient remote control of manufacturing processes. SDN is a renowned paradigm for network softwarization, which has helped facilitate remote manufacturing in association with high network performance, since SDN is designed to control network paths and traffic flows, guaranteeing improved quality of services by obtaining network requests from end-applications on demand through the separated SDN controller or control plane. However, current SDN approaches are generally focused on the controls and automation of the networks, which indicates that there is a lack of management plane development designed for a reliable and fault-tolerant SDN environment. Therefore, in addition to the inherent advantage of SDN, this paper proposes a new software-defined network operations center (SD-NOC) architecture to strengthen the reliability and fault-tolerance of SDN in terms of network operations and management in particular. The cooperation and orchestration between SDN and SD-NOC are also introduced for the SDN failover processes based on four principal SDN breakdown scenarios derived from the failures of the controller, SDN nodes, and connected links. The abovementioned SDN troubles significantly reduce the network reachability to remote devices (e.g., 3D printers, super high-definition cameras, etc.) and the reliability of relevant control processes. Our performance consideration and analysis results show that the proposed scheme can shrink operations and management overheads of SDN, which leads to the enhancement of responsiveness and reliability of SDN for remote 3D printing and control processes.
NASA Technical Reports Server (NTRS)
Hoppa, Mary Ann; Wilson, Larry W.
1994-01-01
There are many software reliability models which try to predict future performance of software based on data generated by the debugging process. Our research has shown that by improving the quality of the data one can greatly improve the predictions. We are working on methodologies which control some of the randomness inherent in the standard data generation processes in order to improve the accuracy of predictions. Our contribution is twofold in that we describe an experimental methodology using a data structure called the debugging graph and apply this methodology to assess the robustness of existing models. The debugging graph is used to analyze the effects of various fault recovery orders on the predictive accuracy of several well-known software reliability algorithms. We found that, along a particular debugging path in the graph, the predictive performance of different models can vary greatly. Similarly, just because a model 'fits' a given path's data well does not guarantee that the model would perform well on a different path. Further we observed bug interactions and noted their potential effects on the predictive process. We saw that not only do different faults fail at different rates, but that those rates can be affected by the particular debugging stage at which the rates are evaluated. Based on our experiment, we conjecture that the accuracy of a reliability prediction is affected by the fault recovery order as well as by fault interaction.
Visconti, Luca; Martin, Conchita
2013-01-01
The aim of this study was to evaluate both intra- and interoperator reliability of a radiological three-dimensional classification system (KPG index) for the assessment of degree of difficulty for orthodontic treatment of maxillary canine impactions. Cone beam computed tomography (CBCT) scans of fifty impacted canines, obtained using three different scanners (NewTom, Kodak, and Planmeca), were classified using the KPG index by three independent orthodontists. Measurements were repeated one month later. Based on these two sessions, several recommendations on KPG Index scoring were elaborated. After a joint calibration session, these recommendations were explained to nine orthodontists and the two measurement sessions were repeated. There was a moderate intrarater agreement in the precalibration measurement sessions. After the calibration session, both intra- and interrater agreement were almost perfect. Indexes assessed with Kodak Dental Imaging 3D module software showed a better reliability in z-axis values, whereas indexes assessed with Planmeca Romexis software showed a better reliability in x- and y-axis values. No differences were found between the CBCT scanners used. Taken together, these findings indicate that the application of the instructions elaborated during this study improved KPG index reliability, which was nevertheless variously influenced by the use of different software for images evaluation. PMID:24235889
Parallel computers - Estimate errors caused by imprecise data
NASA Technical Reports Server (NTRS)
Kreinovich, Vladik; Bernat, Andrew; Villa, Elsa; Mariscal, Yvonne
1991-01-01
A new approach to the problem of estimating errors caused by imprecise data is proposed in the context of software engineering. A software device is used to produce an ideal solution to the problem, when the computer is capable of computing errors of arbitrary programs. The software engineering aspect of this problem is to describe a device for computing the error estimates in software terms and then to provide precise numbers with error estimates to the user. The feasibility of the program capable of computing both some quantity and its error estimate in the range of possible measurement errors is demonstrated.
NASA Technical Reports Server (NTRS)
Shin, Jong-Yeob; Belcastro, Christine
2008-01-01
Formal robustness analysis of aircraft control upset prevention and recovery systems could play an important role in their validation and ultimate certification. As a part of the validation process, this paper describes an analysis method for determining a reliable flight regime in the flight envelope within which an integrated resilent control system can achieve the desired performance of tracking command signals and detecting additive faults in the presence of parameter uncertainty and unmodeled dynamics. To calculate a reliable flight regime, a structured singular value analysis method is applied to analyze the closed-loop system over the entire flight envelope. To use the structured singular value analysis method, a linear fractional transform (LFT) model of a transport aircraft longitudinal dynamics is developed over the flight envelope by using a preliminary LFT modeling software tool developed at the NASA Langley Research Center, which utilizes a matrix-based computational approach. The developed LFT model can capture original nonlinear dynamics over the flight envelope with the ! block which contains key varying parameters: angle of attack and velocity, and real parameter uncertainty: aerodynamic coefficient uncertainty and moment of inertia uncertainty. Using the developed LFT model and a formal robustness analysis method, a reliable flight regime is calculated for a transport aircraft closed-loop system.
A Novel Rules Based Approach for Estimating Software Birthmark
Binti Alias, Norma; Anwar, Sajid
2015-01-01
Software birthmark is a unique quality of software to detect software theft. Comparing birthmarks of software can tell us whether a program or software is a copy of another. Software theft and piracy are rapidly increasing problems of copying, stealing, and misusing the software without proper permission, as mentioned in the desired license agreement. The estimation of birthmark can play a key role in understanding the effectiveness of a birthmark. In this paper, a new technique is presented to evaluate and estimate software birthmark based on the two most sought-after properties of birthmarks, that is, credibility and resilience. For this purpose, the concept of soft computing such as probabilistic and fuzzy computing has been taken into account and fuzzy logic is used to estimate properties of birthmark. The proposed fuzzy rule based technique is validated through a case study and the results show that the technique is successful in assessing the specified properties of the birthmark, its resilience and credibility. This, in turn, shows how much effort will be required to detect the originality of the software based on its birthmark. PMID:25945363
NASA Technical Reports Server (NTRS)
Mizell, Carolyn; Malone, Linda
2007-01-01
It is very difficult for project managers to develop accurate cost and schedule estimates for large, complex software development projects. None of the approaches or tools available today can estimate the true cost of software with any high degree of accuracy early in a project. This paper provides an approach that utilizes a software development process simulation model that considers and conveys the level of uncertainty that exists when developing an initial estimate. A NASA project will be analyzed using simulation and data from the Software Engineering Laboratory to show the benefits of such an approach.
A second generation experiment in fault-tolerant software
NASA Technical Reports Server (NTRS)
Knight, J. C.
1986-01-01
The primary goal was to determine whether the application of fault tolerance to software increases its reliability if the cost of production is the same as for an equivalent nonfault tolerance version derived from the same requirements specification. Software development protocols are discussed. The feasibility of adapting to software design fault tolerance the technique of N-fold Modular Redundancy with majority voting was studied.
Ozaki, Y; Watanabe, H; Kaida, A; Miura, M; Nakagawa, K; Toda, K; Yoshimura, R; Sumi, Y; Kurabayashi, T
2017-07-01
Early stage oral cancer can be cured with oral brachytherapy, but whole-body radiation exposure status has not been previously studied. Recently, the International Commission on Radiological Protection Committee (ICRP) recommended the use of ICRP phantoms to estimate radiation exposure from external and internal radiation sources. In this study, we used a Monte Carlo simulation with ICRP phantoms to estimate whole-body exposure from oral brachytherapy. We used a Particle and Heavy Ion Transport code System (PHITS) to model oral brachytherapy with 192Ir hairpins and 198Au grains and to perform a Monte Carlo simulation on the ICRP adult reference computational phantoms. To confirm the simulations, we also computed local dose distributions from these small sources, and compared them with the results from Oncentra manual Low Dose Rate Treatment Planning (mLDR) software which is used in day-to-day clinical practice. We successfully obtained data on absorbed dose for each organ in males and females. Sex-averaged equivalent doses were 0.547 and 0.710 Sv with 192Ir hairpins and 198Au grains, respectively. Simulation with PHITS was reliable when compared with an alternative computational technique using mLDR software. We concluded that the absorbed dose for each organ and whole-body exposure from oral brachytherapy can be estimated with Monte Carlo simulation using PHITS on ICRP reference phantoms. Effective doses for patients with oral cancer were obtained. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
Quantitative analysis of tympanic membrane perforation: a simple and reliable method.
Ibekwe, T S; Adeosun, A A; Nwaorgu, O G
2009-01-01
Accurate assessment of the features of tympanic membrane perforation, especially size, site, duration and aetiology, is important, as it enables optimum management. To describe a simple, cheap and effective method of quantitatively analysing tympanic membrane perforations. The system described comprises a video-otoscope (capable of generating still and video images of the tympanic membrane), adapted via a universal serial bus box to a computer screen, with images analysed using the Image J geometrical analysis software package. The reproducibility of results and their correlation with conventional otoscopic methods of estimation were tested statistically with the paired t-test and correlational tests, using the Statistical Package for the Social Sciences version 11 software. The following equation was generated: P/T x 100 per cent = percentage perforation, where P is the area (in pixels2) of the tympanic membrane perforation and T is the total area (in pixels2) for the entire tympanic membrane (including the perforation). Illustrations are shown. Comparison of blinded data on tympanic membrane perforation area obtained independently from assessments by two trained otologists, of comparative years of experience, using the video-otoscopy system described, showed similar findings, with strong correlations devoid of inter-observer error (p = 0.000, r = 1). Comparison with conventional otoscopic assessment also indicated significant correlation, comparing results for two trained otologists, but some inter-observer variation was present (p = 0.000, r = 0.896). Correlation between the two methods for each of the otologists was also highly significant (p = 0.000). A computer-adapted video-otoscope, with images analysed by Image J software, represents a cheap, reliable, technology-driven, clinical method of quantitative analysis of tympanic membrane perforations and injuries.
PD5: a general purpose library for primer design software.
Riley, Michael C; Aubrey, Wayne; Young, Michael; Clare, Amanda
2013-01-01
Complex PCR applications for large genome-scale projects require fast, reliable and often highly sophisticated primer design software applications. Presently, such applications use pipelining methods to utilise many third party applications and this involves file parsing, interfacing and data conversion, which is slow and prone to error. A fully integrated suite of software tools for primer design would considerably improve the development time, the processing speed, and the reliability of bespoke primer design software applications. The PD5 software library is an open-source collection of classes and utilities, providing a complete collection of software building blocks for primer design and analysis. It is written in object-oriented C(++) with an emphasis on classes suitable for efficient and rapid development of bespoke primer design programs. The modular design of the software library simplifies the development of specific applications and also integration with existing third party software where necessary. We demonstrate several applications created using this software library that have already proved to be effective, but we view the project as a dynamic environment for building primer design software and it is open for future development by the bioinformatics community. Therefore, the PD5 software library is published under the terms of the GNU General Public License, which guarantee access to source-code and allow redistribution and modification. The PD5 software library is downloadable from Google Code and the accompanying Wiki includes instructions and examples: http://code.google.com/p/primer-design.
A real-time monitoring system for the facial nerve.
Prell, Julian; Rachinger, Jens; Scheller, Christian; Alfieri, Alex; Strauss, Christian; Rampp, Stefan
2010-06-01
Damage to the facial nerve during surgery in the cerebellopontine angle is indicated by A-trains, a specific electromyogram pattern. These A-trains can be quantified by the parameter "traintime," which is reliably correlated with postoperative functional outcome. The system presented was designed to monitor traintime in real-time. A dedicated hardware and software platform for automated continuous analysis of the intraoperative facial nerve electromyogram was specifically designed. The automatic detection of A-trains is performed by a software algorithm for real-time analysis of nonstationary biosignals. The system was evaluated in a series of 30 patients operated on for vestibular schwannoma. A-trains can be detected and measured automatically by the described method for real-time analysis. Traintime is monitored continuously via a graphic display and is shown as an absolute numeric value during the operation. It is an expression of overall, cumulated length of A-trains in a given channel; a high correlation between traintime as measured by real-time analysis and functional outcome immediately after the operation (Spearman correlation coefficient [rho] = 0.664, P < .001) and in long-term outcome (rho = 0.631, P < .001) was observed. Automated real-time analysis of the intraoperative facial nerve electromyogram is the first technique capable of reliable continuous real-time monitoring. It can critically contribute to the estimation of functional outcome during the course of the operative procedure.
SOFIA: a flexible source finder for 3D spectral line data
NASA Astrophysics Data System (ADS)
Serra, Paolo; Westmeier, Tobias; Giese, Nadine; Jurek, Russell; Flöer, Lars; Popping, Attila; Winkel, Benjamin; van der Hulst, Thijs; Meyer, Martin; Koribalski, Bärbel S.; Staveley-Smith, Lister; Courtois, Hélène
2015-04-01
We introduce SOFIA, a flexible software application for the detection and parametrization of sources in 3D spectral line data sets. SOFIA combines for the first time in a single piece of software a set of new source-finding and parametrization algorithms developed on the way to future H I surveys with ASKAP (WALLABY, DINGO) and APERTIF. It is designed to enable the general use of these new algorithms by the community on a broad range of data sets. The key advantages of SOFIA are the ability to: search for line emission on multiple scales to detect 3D sources in a complete and reliable way, taking into account noise level variations and the presence of artefacts in a data cube; estimate the reliability of individual detections; look for signal in arbitrarily large data cubes using a catalogue of 3D coordinates as a prior; provide a wide range of source parameters and output products which facilitate further analysis by the user. We highlight the modularity of SOFIA, which makes it a flexible package allowing users to select and apply only the algorithms useful for their data and science questions. This modularity makes it also possible to easily expand SOFIA in order to include additional methods as they become available. The full SOFIA distribution, including a dedicated graphical user interface, is publicly available for download.
NASA Technical Reports Server (NTRS)
Ebeling, Charles
1993-01-01
This report documents the work accomplished during the first two years of research to provide support to NASA in predicting operational and support parameters and costs of proposed space systems. The first year's research developed a methodology for deriving reliability and maintainability (R & M) parameters based upon the use of regression analysis to establish empirical relationships between performance and design specifications and corresponding mean times of failure and repair. The second year focused on enhancements to the methodology, increased scope of the model, and software improvements. This follow-on effort expands the prediction of R & M parameters and their effect on the operations and support of space transportation vehicles to include other system components such as booster rockets and external fuel tanks. It also increases the scope of the methodology and the capabilities of the model as implemented by the software. The focus is on the failure and repair of major subsystems and their impact on vehicle reliability, turn times, maintenance manpower, and repairable spares requirements. The report documents the data utilized in this study, outlines the general methodology for estimating and relating R&M parameters, presents the analyses and results of application to the initial data base, and describes the implementation of the methodology through the use of a computer model. The report concludes with a discussion on validation and a summary of the research findings and results.
Pedersen, E S L; Danquah, I H; Petersen, C B; Tolstrup, J S
2016-12-03
Accelerometers can obtain precise measurements of movements during the day. However, the individual activity pattern varies from day-to-day and there is limited evidence on measurement days needed to obtain sufficient reliability. The aim of this study was to examine variability in accelerometer derived data on sedentary behaviour and physical activity at work and in leisure-time during week days among Danish office employees. We included control participants (n = 135) from the Take a Stand! Intervention; a cluster randomized controlled trial conducted in 19 offices. Sitting time and physical activity were measured using an ActiGraph GT3X+ fixed on the thigh and data were processed using Acti4 software. Variability was examined for sitting time, standing time, steps and time spent in moderate-to-vigorous physical activity (MVPA) per day by multilevel mixed linear regression modelling. Results of this study showed that the number of days needed to obtain a reliability of 80% when measuring sitting time was 4.7 days for work and 5.5 days for leisure time. For physical activity at work, 4.0 days and 4.2 days were required to measure steps and MVPA, respectively. During leisure time, more monitoring time was needed to reliably estimate physical activity (6.8 days for steps and 5.8 days for MVPA). The number of measurement days needed to reliably estimate activity patterns was greater for leisure time than for work time. The domain specific variability is of great importance to researchers and health promotion workers planning to use objective measures of sedentary behaviour and physical activity. Clinical trials NCT01996176 .
NASA Technical Reports Server (NTRS)
Leveson, Nancy
1987-01-01
Software safety and its relationship to other qualities are discussed. It is shown that standard reliability and fault tolerance techniques will not solve the safety problem for the present. A new attitude requires: looking at what you do NOT want software to do along with what you want it to do; and assuming things will go wrong. New procedures and changes to entire software development process are necessary: special software safety analysis techniques are needed; and design techniques, especially eliminating complexity, can be very helpful.
The Software Management Environment (SME)
NASA Technical Reports Server (NTRS)
Valett, Jon D.; Decker, William; Buell, John
1988-01-01
The Software Management Environment (SME) is a research effort designed to utilize the past experiences and results of the Software Engineering Laboratory (SEL) and to incorporate this knowledge into a tool for managing projects. SME provides the software development manager with the ability to observe, compare, predict, analyze, and control key software development parameters such as effort, reliability, and resource utilization. The major components of the SME, the architecture of the system, and examples of the functionality of the tool are discussed.
Deep space network software cost estimation model
NASA Technical Reports Server (NTRS)
Tausworthe, R. C.
1981-01-01
A parametric software cost estimation model prepared for Jet PRopulsion Laboratory (JPL) Deep Space Network (DSN) Data System implementation tasks is described. The resource estimation mdel modifies and combines a number of existing models. The model calibrates the task magnitude and difficulty, development environment, and software technology effects through prompted responses to a set of approximately 50 questions. Parameters in the model are adjusted to fit JPL software life-cycle statistics.
Cloud Computing for the Grid: GridControl: A Software Platform to Support the Smart Grid
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
GENI Project: Cornell University is creating a new software platform for grid operators called GridControl that will utilize cloud computing to more efficiently control the grid. In a cloud computing system, there are minimal hardware and software demands on users. The user can tap into a network of computers that is housed elsewhere (the cloud) and the network runs computer applications for the user. The user only needs interface software to access all of the cloud’s data resources, which can be as simple as a web browser. Cloud computing can reduce costs, facilitate innovation through sharing, empower users, and improvemore » the overall reliability of a dispersed system. Cornell’s GridControl will focus on 4 elements: delivering the state of the grid to users quickly and reliably; building networked, scalable grid-control software; tailoring services to emerging smart grid uses; and simulating smart grid behavior under various conditions.« less
DOT National Transportation Integrated Search
2013-04-01
The Rural Road Upgrade Inventory and Cost Estimation Software is designed by the AUTC : research team to help the Fairbanks North Star Borough (FNSB) estimate the cost of upgrading : rural roads located in the Borough's Service Areas. The Software pe...
Technique for Early Reliability Prediction of Software Components Using Behaviour Models
Ali, Awad; N. A. Jawawi, Dayang; Adham Isa, Mohd; Imran Babar, Muhammad
2016-01-01
Behaviour models are the most commonly used input for predicting the reliability of a software system at the early design stage. A component behaviour model reveals the structure and behaviour of the component during the execution of system-level functionalities. There are various challenges related to component reliability prediction at the early design stage based on behaviour models. For example, most of the current reliability techniques do not provide fine-grained sequential behaviour models of individual components and fail to consider the loop entry and exit points in the reliability computation. Moreover, some of the current techniques do not tackle the problem of operational data unavailability and the lack of analysis results that can be valuable for software architects at the early design stage. This paper proposes a reliability prediction technique that, pragmatically, synthesizes system behaviour in the form of a state machine, given a set of scenarios and corresponding constraints as input. The state machine is utilized as a base for generating the component-relevant operational data. The state machine is also used as a source for identifying the nodes and edges of a component probabilistic dependency graph (CPDG). Based on the CPDG, a stack-based algorithm is used to compute the reliability. The proposed technique is evaluated by a comparison with existing techniques and the application of sensitivity analysis to a robotic wheelchair system as a case study. The results indicate that the proposed technique is more relevant at the early design stage compared to existing works, and can provide a more realistic and meaningful prediction. PMID:27668748
75 FR 4375 - Transmission Loading Relief Reliability Standard and Curtailment Priorities
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-27
... Site: http://www.ferc.gov . Documents created electronically using word processing software should be... ensure operation within acceptable reliability criteria. NERC Glossary of Terms Used in Reliability Standards at 19, available at http://www.nerc.com/files/Glossary_12Feb08.pdf (NERC Glossary). An...
Comparison of software tools for kinetic evaluation of chemical degradation data.
Ranke, Johannes; Wöltjen, Janina; Meinecke, Stefan
2018-01-01
For evaluating the fate of xenobiotics in the environment, a variety of degradation or environmental metabolism experiments are routinely conducted. The data generated in such experiments are evaluated by optimizing the parameters of kinetic models in a way that the model simulation fits the data. No comparison of the main software tools currently in use has been published to date. This article shows a comparison of numerical results as well as an overall, somewhat subjective comparison based on a scoring system using a set of criteria. The scoring was separately performed for two types of uses. Uses of type I are routine evaluations involving standard kinetic models and up to three metabolites in a single compartment. Evaluations involving non-standard model components, more than three metabolites or more than a single compartment belong to use type II. For use type I, usability is most important, while the flexibility of the model definition is most important for use type II. Test datasets were assembled that can be used to compare the numerical results for different software tools. These datasets can also be used to ensure that no unintended or erroneous behaviour is introduced in newer versions. In the comparison of numerical results, good agreement between the parameter estimates was observed for datasets with up to three metabolites. For the now unmaintained reference software DegKinManager/ModelMaker, and for OpenModel which is still under development, user options were identified that should be taken care of in order to obtain results that are as reliable as possible. Based on the scoring system mentioned above, the software tools gmkin, KinGUII and CAKE received the best scores for use type I. Out of the 15 software packages compared with respect to use type II, again gmkin and KinGUII were the first two, followed by the script based tool mkin, which is the technical basis for gmkin, and by OpenModel. Based on the evaluation using the system of criteria mentioned above and the comparison of numerical results for the suite of test datasets, the software tools gmkin, KinGUII and CAKE are recommended for use type I, and gmkin and KinGUII for use type II. For users that prefer to work with scripts instead of graphical user interfaces, mkin is recommended. For future software evaluations, it is recommended to include a measure for the total time that a typical user needs for a kinetic evaluation into the scoring scheme. It is the hope of the authors that the publication of test data, source code and overall rankings foster the evolution of useful and reliable software in the field.
NASA Technical Reports Server (NTRS)
Singhal, Surendra N.
2003-01-01
The SAE G-11 RMSL (Reliability, Maintainability, Supportability, and Logistics) Division activities include identification and fulfillment of joint industry, government, and academia needs for development and implementation of RMSL technologies. Four Projects in the Probabilistic Methods area and two in the area of RMSL have been identified. These are: (1) Evaluation of Probabilistic Technology - progress has been made toward the selection of probabilistic application cases. Future effort will focus on assessment of multiple probabilistic softwares in solving selected engineering problems using probabilistic methods. Relevance to Industry & Government - Case studies of typical problems encountering uncertainties, results of solutions to these problems run by different codes, and recommendations on which code is applicable for what problems; (2) Probabilistic Input Preparation - progress has been made in identifying problem cases such as those with no data, little data and sufficient data. Future effort will focus on developing guidelines for preparing input for probabilistic analysis, especially with no or little data. Relevance to Industry & Government - Too often, we get bogged down thinking we need a lot of data before we can quantify uncertainties. Not True. There are ways to do credible probabilistic analysis with little data; (3) Probabilistic Reliability - probabilistic reliability literature search has been completed along with what differentiates it from statistical reliability. Work on computation of reliability based on quantification of uncertainties in primitive variables is in progress. Relevance to Industry & Government - Correct reliability computations both at the component and system level are needed so one can design an item based on its expected usage and life span; (4) Real World Applications of Probabilistic Methods (PM) - A draft of volume 1 comprising aerospace applications has been released. Volume 2, a compilation of real world applications of probabilistic methods with essential information demonstrating application type and timehost savings by the use of probabilistic methods for generic applications is in progress. Relevance to Industry & Government - Too often, we say, 'The Proof is in the Pudding'. With help from many contributors, we hope to produce such a document. Problem is - not too many people are coming forward due to proprietary nature. So, we are asking to document only minimum information including problem description, what method used, did it result in any savings, and how much?; (5) Software Reliability - software reliability concept, program, implementation, guidelines, and standards are being documented. Relevance to Industry & Government - software reliability is a complex issue that must be understood & addressed in all facets of business in industry, government, and other institutions. We address issues, concepts, ways to implement solutions, and guidelines for maximizing software reliability; (6) Maintainability Standards - maintainability/serviceability industry standard/guidelines and industry best practices and methodologies used in performing maintainability/ serviceability tasks are being documented. Relevance to Industry & Government - Any industry or government process, project, and/or tool must be maintained and serviced to realize the life and performance it was designed for. We address issues and develop guidelines for optimum performance & life.
Cryogenic instrumentation for ITER magnets
NASA Astrophysics Data System (ADS)
Poncet, J.-M.; Manzagol, J.; Attard, A.; André, J.; Bizel-Bizellot, L.; Bonnay, P.; Ercolani, E.; Luchier, N.; Girard, A.; Clayton, N.; Devred, A.; Huygen, S.; Journeaux, J.-Y.
2017-02-01
Accurate measurements of the helium flowrate and of the temperature of the ITER magnets is of fundamental importance to make sure that the magnets operate under well controlled and reliable conditions, and to allow suitable helium flow distribution in the magnets through the helium piping. Therefore, the temperature and flow rate measurements shall be reliable and accurate. In this paper, we present the thermometric chains as well as the venturi flow meters installed in the ITER magnets and their helium piping. The presented thermometric block design is based on the design developed by CERN for the LHC, which has been further optimized via thermal simulations carried out by CEA. The electronic part of the thermometric chain was entirely developed by the CEA and will be presented in detail: it is based on a lock-in measurement and small signal amplification, and also provides a web interface and software to an industrial PLC. This measuring device provides a reliable, accurate, electromagnetically immune, and fast (up to 100 Hz bandwidth) system for resistive temperature sensors between a few ohms to 100 kΩ. The flowmeters (venturi type) which make up part of the helium mass flow measurement chain have been completely designed, and manufacturing is on-going. The behaviour of the helium gas has been studied in detailed thanks to ANSYS CFX software in order to obtain the same differential pressure for all types of flowmeters. Measurement uncertainties have been estimated and the influence of input parameters has been studied. Mechanical calculations have been performed to guarantee the mechanical strength of the venturis required for pressure equipment operating in nuclear environment. In order to complete the helium mass flow measurement chain, different technologies of absolute and differential pressure sensors have been tested in an applied magnetic field to identify equipment compatible with the ITER environment.
Bosquet, Laurent; Porta-Benache, Jeremy; Blais, Jérôme
2010-01-01
The aim of this study was to assess the validity and accuracy of a commercial linear encoder (Musclelab, Ergotest, Norway) to estimate Bench press 1 repetition maximum (1RM) from the force - velocity relationship. Twenty seven physical education students and teachers (5 women and 22 men) with a heterogeneous history of strength training participated in this study. They performed a 1 RM test and a force - velocity test using a Bench press lifting task in a random order. Mean 1 RM was 61.8 ± 15.3 kg (range: 34 to 100 kg), while 1 RM estimated by the Musclelab's software from the force-velocity relationship was 56.4 ± 14.0 kg (range: 33 to 91 kg). Actual and estimated 1 RM were very highly correlated (r = 0.93, p<0.001) but largely different (Bias: 5.4 ± 5.7 kg, p < 0.001, ES = 1.37). The 95% limits of agreement were ±11.2 kg, which represented ±18% of actual 1 RM. It was concluded that 1 RM estimated from the force-velocity relationship was a good measure for monitoring training induced adaptations, but also that it was not accurate enough to prescribe training intensities. Additional studies are required to determine whether accuracy is affected by age, sex or initial level. Key pointsSome commercial devices allow to estimate 1 RM from the force-velocity relationship.These estimations are valid. However, their accuracy is not high enough to be of practical help for training intensity prescription.Day-to-day reliability of force and velocity measured by the linear encoder has been shown to be very high, but the specific reliability of 1 RM estimated from the force-velocity relationship has to be determined before concluding to the usefulness of this approach in the monitoring of training induced adaptations.
Bosquet, Laurent; Porta-Benache, Jeremy; Blais, Jérôme
2010-01-01
The aim of this study was to assess the validity and accuracy of a commercial linear encoder (Musclelab, Ergotest, Norway) to estimate Bench press 1 repetition maximum (1RM) from the force - velocity relationship. Twenty seven physical education students and teachers (5 women and 22 men) with a heterogeneous history of strength training participated in this study. They performed a 1 RM test and a force - velocity test using a Bench press lifting task in a random order. Mean 1 RM was 61.8 ± 15.3 kg (range: 34 to 100 kg), while 1 RM estimated by the Musclelab’s software from the force-velocity relationship was 56.4 ± 14.0 kg (range: 33 to 91 kg). Actual and estimated 1 RM were very highly correlated (r = 0.93, p<0.001) but largely different (Bias: 5.4 ± 5.7 kg, p < 0.001, ES = 1.37). The 95% limits of agreement were ±11.2 kg, which represented ±18% of actual 1 RM. It was concluded that 1 RM estimated from the force-velocity relationship was a good measure for monitoring training induced adaptations, but also that it was not accurate enough to prescribe training intensities. Additional studies are required to determine whether accuracy is affected by age, sex or initial level. Key points Some commercial devices allow to estimate 1 RM from the force-velocity relationship. These estimations are valid. However, their accuracy is not high enough to be of practical help for training intensity prescription. Day-to-day reliability of force and velocity measured by the linear encoder has been shown to be very high, but the specific reliability of 1 RM estimated from the force-velocity relationship has to be determined before concluding to the usefulness of this approach in the monitoring of training induced adaptations. PMID:24149641
Fayed, Nicolas; Modrego, Pedro J; Medrano, Jaime
2009-06-01
Reproducibility is an essential strength of any diagnostic technique for cross-sectional and longitudinal works. To determine in vivo short-term comparatively, the test-retest reliability of magnetic resonance spectroscopy (MRS) of the brain was compared using the manufacturer's software package and the widely used linear combination of model (LCModel) technique. Single-voxel H-MRS was performed in a series of patients with different pathologies on a 1.5 T clinical scanner. Four areas of the brain were explored with the point resolved spectroscopy technique acquisition mode; the echo time was 35 milliseconds and the repetition time was 2000 milliseconds. We enrolled 15 patients for every area, and the intra-individual variations of metabolites were studied in two consecutive scans without removing the patient from the scanner. Curve fitting and analysis of metabolites were made with the software of GE and the LCModel. Spectra non-fulfilling the minimum criteria of quality in relation to linewidths and signal/noise ratio were rejected. The intraclass correlation coefficients for the N-acetylaspartate/creatine (NAA/Cr) ratios were 0.93, 0.89, 0.9 and 0.8 for the posterior cingulate gyrus, occipital, prefrontal and temporal regions, respectively, with the GE software. For the LCModel, the coefficients were 0.9, 0.89, 0.87 and 0.84, respectively. For the absolute value of NAA, the GE software was also slightly more reproducible than LCModel. However, for the choline/Cr and myo-inositol/Cr ratios, the LCModel was more reliable than the GE software. The variability we have seen hovers around the percentages observed in previous reports (around 10% for the NAA/Cr ratios). We did not find that the LCModel software is superior to the software of the manufacturer. Reproducibility of metabolite values relies more on the observance of the quality parameters than on the software used.
Improvement of Computer Software Quality through Software Automated Tools.
1986-08-31
requirement for increased emphasis on software quality assurance has lead to the creation of various methods of verification and validation. Experience...result was a vast array of methods , systems, languages and automated tools to assist in the process. Given that the primary role of quality assurance is...Unfortunately, there is no single method , tool or technique that can insure accurate, reliable and cost effective software. Therefore, government and industry
2014-08-01
technologies and processes to achieve a required level of confidence that software systems and services function in the intended manner. 1.3 Security Example...that took three high-voltage lines out of service and a software fail- ure (a race condition3) that disabled the computing service that notified the... service had failed. Instead of analyzing the details of the alarm server failure, the reviewers asked why the following software assurance claim had
The research and practice of spacecraft software engineering
NASA Astrophysics Data System (ADS)
Chen, Chengxin; Wang, Jinghua; Xu, Xiaoguang
2017-06-01
In order to ensure the safety and reliability of spacecraft software products, it is necessary to execute engineering management. Firstly, the paper introduces the problems of unsystematic planning, uncertain classified management and uncontinuous improved mechanism in domestic and foreign spacecraft software engineering management. Then, it proposes a solution for software engineering management based on system-integrated ideology in the perspective of spacecraft system. Finally, a application result of spacecraft is given as an example. The research can provides a reference for executing spacecraft software engineering management and improving software product quality.
NASA Technical Reports Server (NTRS)
Simmons, D. B.; Marchbanks, M. P., Jr.; Quick, M. J.
1982-01-01
The results of an effort to thoroughly and objectively analyze the statistical and historical information gathered during the development of the Shuttle Orbiter Primary Flight Software are given. The particular areas of interest include cost of the software, reliability of the software, requirements for the software and how the requirements changed during development of the system. Data related to the current version of the software system produced some interesting results. Suggestions are made for the saving of additional data which will allow additional investigation.
The reliable multicast protocol application programming interface
NASA Technical Reports Server (NTRS)
Montgomery , Todd; Whetten, Brian
1995-01-01
The Application Programming Interface for the Berkeley/WVU implementation of the Reliable Multicast Protocol is described. This transport layer protocol is implemented as a user library that applications and software buses link against.
Spielman, Stephanie J; Wilke, Claus O
2016-11-01
The mutation-selection model of coding sequence evolution has received renewed attention for its use in estimating site-specific amino acid propensities and selection coefficient distributions. Two computationally tractable mutation-selection inference frameworks have been introduced: One framework employs a fixed-effects, highly parameterized maximum likelihood approach, whereas the other employs a random-effects Bayesian Dirichlet Process approach. While both implementations follow the same model, they appear to make distinct predictions about the distribution of selection coefficients. The fixed-effects framework estimates a large proportion of highly deleterious substitutions, whereas the random-effects framework estimates that all substitutions are either nearly neutral or weakly deleterious. It remains unknown, however, how accurately each method infers evolutionary constraints at individual sites. Indeed, selection coefficient distributions pool all site-specific inferences, thereby obscuring a precise assessment of site-specific estimates. Therefore, in this study, we use a simulation-based strategy to determine how accurately each approach recapitulates the selective constraint at individual sites. We find that the fixed-effects approach, despite its extensive parameterization, consistently and accurately estimates site-specific evolutionary constraint. By contrast, the random-effects Bayesian approach systematically underestimates the strength of natural selection, particularly for slowly evolving sites. We also find that, despite the strong differences between their inferred selection coefficient distributions, the fixed- and random-effects approaches yield surprisingly similar inferences of site-specific selective constraint. We conclude that the fixed-effects mutation-selection framework provides the more reliable software platform for model application and future development. © The Author 2016. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Gajewski, Byron J.; Jiang, Yu; Yeh, Hung-Wen; Engelman, Kimberly; Teel, Cynthia; Choi, Won S.; Greiner, K. Allen; Daley, Christine Makosky
2013-01-01
Texts and software that we are currently using for teaching multivariate analysis to non-statisticians lack in the delivery of confirmatory factor analysis (CFA). The purpose of this paper is to provide educators with a complement to these resources that includes CFA and its computation. We focus on how to use CFA to estimate a “composite reliability” of a psychometric instrument. This paper provides guidance for introducing, via a case-study, the non-statistician to CFA. As a complement to our instruction about the more traditional SPSS, we successfully piloted the software R for estimating CFA on nine non-statisticians. This approach can be used with healthcare graduate students taking a multivariate course, as well as modified for community stakeholders of our Center for American Indian Community Health (e.g. community advisory boards, summer interns, & research team members). The placement of CFA at the end of the class is strategic and gives us an opportunity to do some innovative teaching: (1) build ideas for understanding the case study using previous course work (such as ANOVA); (2) incorporate multi-dimensional scaling (that students already learned) into the selection of a factor structure (new concept); (3) use interactive data from the students (active learning); (4) review matrix algebra and its importance to psychometric evaluation; (5) show students how to do the calculation on their own; and (6) give students access to an actual recent research project. PMID:24772373
Lo, Yuan-Chieh; Hu, Yuh-Chung; Chang, Pei-Zen
2018-01-01
Thermal characteristic analysis is essential for machine tool spindles because sudden failures may occur due to unexpected thermal issue. This article presents a lumped-parameter Thermal Network Model (TNM) and its parameter estimation scheme, including hardware and software, in order to characterize both the steady-state and transient thermal behavior of machine tool spindles. For the hardware, the authors develop a Bluetooth Temperature Sensor Module (BTSM) which accompanying with three types of temperature-sensing probes (magnetic, screw, and probe). Its specification, through experimental test, achieves to the precision ±(0.1 + 0.0029|t|) °C, resolution 0.00489 °C, power consumption 7 mW, and size Ø40 mm × 27 mm. For the software, the heat transfer characteristics of the machine tool spindle correlative to rotating speed are derived based on the theory of heat transfer and empirical formula. The predictive TNM of spindles was developed by grey-box estimation and experimental results. Even under such complicated operating conditions as various speeds and different initial conditions, the experiments validate that the present modeling methodology provides a robust and reliable tool for the temperature prediction with normalized mean square error of 99.5% agreement, and the present approach is transferable to the other spindles with a similar structure. For realizing the edge computing in smart manufacturing, a reduced-order TNM is constructed by Model Order Reduction (MOR) technique and implemented into the real-time embedded system. PMID:29473877
Lo, Yuan-Chieh; Hu, Yuh-Chung; Chang, Pei-Zen
2018-02-23
Thermal characteristic analysis is essential for machine tool spindles because sudden failures may occur due to unexpected thermal issue. This article presents a lumped-parameter Thermal Network Model (TNM) and its parameter estimation scheme, including hardware and software, in order to characterize both the steady-state and transient thermal behavior of machine tool spindles. For the hardware, the authors develop a Bluetooth Temperature Sensor Module (BTSM) which accompanying with three types of temperature-sensing probes (magnetic, screw, and probe). Its specification, through experimental test, achieves to the precision ±(0.1 + 0.0029|t|) °C, resolution 0.00489 °C, power consumption 7 mW, and size Ø40 mm × 27 mm. For the software, the heat transfer characteristics of the machine tool spindle correlative to rotating speed are derived based on the theory of heat transfer and empirical formula. The predictive TNM of spindles was developed by grey-box estimation and experimental results. Even under such complicated operating conditions as various speeds and different initial conditions, the experiments validate that the present modeling methodology provides a robust and reliable tool for the temperature prediction with normalized mean square error of 99.5% agreement, and the present approach is transferable to the other spindles with a similar structure. For realizing the edge computing in smart manufacturing, a reduced-order TNM is constructed by Model Order Reduction (MOR) technique and implemented into the real-time embedded system.
Poleti, Marcelo Lupion; Fernandes, Thais Maria Freire; Pagin, Otávio; Moretti, Marcela Rodrigues; Rubira-Bullen, Izabel Regina Fischer
2016-01-01
The aim of this in vitro study was to evaluate the reliability and accuracy of linear measurements on three-dimensional (3D) surface models obtained by standard pre-set thresholds in two segmentation software programs. Ten mandibles with 17 silica markers were scanned for 0.3-mm voxels in the i-CAT Classic (Imaging Sciences International, Hatfield, PA, USA). Twenty linear measurements were carried out by two observers two times on the 3D surface models: the Dolphin Imaging 11.5 (Dolphin Imaging & Management Solutions, Chatsworth, CA, USA), using two filters(Translucent and Solid-1), and in the InVesalius 3.0.0 (Centre for Information Technology Renato Archer, Campinas, SP, Brazil). The physical measurements were made by another observer two times using a digital caliper on the dry mandibles. Excellent intra- and inter-observer reliability for the markers, physical measurements, and 3D surface models were found (intra-class correlation coefficient (ICC) and Pearson's r ≥ 0.91). The linear measurements on 3D surface models by Dolphin and InVesalius software programs were accurate (Dolphin Solid-1 > InVesalius > Dolphin Translucent). The highest absolute and percentage errors were obtained for the variable R1-R1 (1.37 mm) and MF-AC (2.53 %) in the Dolphin Translucent and InVesalius software, respectively. Linear measurements on 3D surface models obtained by standard pre-set thresholds in the Dolphin and InVesalius software programs are reliable and accurate compared with physical measurements. Studies that evaluate the reliability and accuracy of the 3D models are necessary to ensure error predictability and to establish diagnosis, treatment plan, and prognosis in a more realistic way.
Probabilistic Prediction of Lifetimes of Ceramic Parts
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Gyekenyesi, John P.; Jadaan, Osama M.; Palfi, Tamas; Powers, Lynn; Reh, Stefan; Baker, Eric H.
2006-01-01
ANSYS/CARES/PDS is a software system that combines the ANSYS Probabilistic Design System (PDS) software with a modified version of the Ceramics Analysis and Reliability Evaluation of Structures Life (CARES/Life) Version 6.0 software. [A prior version of CARES/Life was reported in Program for Evaluation of Reliability of Ceramic Parts (LEW-16018), NASA Tech Briefs, Vol. 20, No. 3 (March 1996), page 28.] CARES/Life models effects of stochastic strength, slow crack growth, and stress distribution on the overall reliability of a ceramic component. The essence of the enhancement in CARES/Life 6.0 is the capability to predict the probability of failure using results from transient finite-element analysis. ANSYS PDS models the effects of uncertainty in material properties, dimensions, and loading on the stress distribution and deformation. ANSYS/CARES/PDS accounts for the effects of probabilistic strength, probabilistic loads, probabilistic material properties, and probabilistic tolerances on the lifetime and reliability of the component. Even failure probability becomes a stochastic quantity that can be tracked as a response variable. ANSYS/CARES/PDS enables tracking of all stochastic quantities in the design space, thereby enabling more precise probabilistic prediction of lifetimes of ceramic components.
Reliability of infarct volumetry: Its relevance and the improvement by a software-assisted approach.
Friedländer, Felix; Bohmann, Ferdinand; Brunkhorst, Max; Chae, Ju-Hee; Devraj, Kavi; Köhler, Yvette; Kraft, Peter; Kuhn, Hannah; Lucaciu, Alexandra; Luger, Sebastian; Pfeilschifter, Waltraud; Sadler, Rebecca; Liesz, Arthur; Scholtyschik, Karolina; Stolz, Leonie; Vutukuri, Rajkumar; Brunkhorst, Robert
2017-08-01
Despite the efficacy of neuroprotective approaches in animal models of stroke, their translation has so far failed from bench to bedside. One reason is presumed to be a low quality of preclinical study design, leading to bias and a low a priori power. In this study, we propose that the key read-out of experimental stroke studies, the volume of the ischemic damage as commonly measured by free-handed planimetry of TTC-stained brain sections, is subject to an unrecognized low inter-rater and test-retest reliability with strong implications for statistical power and bias. As an alternative approach, we suggest a simple, open-source, software-assisted method, taking advantage of automatic-thresholding techniques. The validity and the improvement of reliability by an automated method to tMCAO infarct volumetry are demonstrated. In addition, we show the probable consequences of increased reliability for precision, p-values, effect inflation, and power calculation, exemplified by a systematic analysis of experimental stroke studies published in the year 2015. Our study reveals an underappreciated quality problem in translational stroke research and suggests that software-assisted infarct volumetry might help to improve reproducibility and therefore the robustness of bench to bedside translation.
Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Daioku, Tomihiko; Toyama, Hiroshi; Kato, Ryoichi
2017-05-01
Adequate dose management during computed tomography is important. In the present study, the dosimetric application software ImPACT was added to a functional calculator of the size-specific dose estimate and was part of the scan settings for the auto exposure control (AEC) technique. This study aimed to assess the practicality and accuracy of the modified ImPACT software for dose estimation. We compared the conversion factors identified by the software with the values reported by the American Association of Physicists in Medicine Task Group 204, and we noted similar results. Moreover, doses were calculated with the AEC technique and a fixed-tube current of 200 mA for the chest-pelvis region. The modified ImPACT software could estimate each organ dose, which was based on the modulated tube current. The ability to perform beneficial modifications indicates the flexibility of the ImPACT software. The ImPACT software can be further modified for estimation of other doses. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ramsthaler, F; Kreutz, K; Verhoff, M A
2007-11-01
It has been generally accepted in skeletal sex determination that the use of metric methods is limited due to the population dependence of the multivariate algorithms. The aim of the study was to verify the applicability of software-based sex estimations outside the reference population group for which discriminant equations have been developed. We examined 98 skulls from recent forensic cases of known age, sex, and Caucasian ancestry from cranium collections in Frankfurt and Mainz (Germany) to determine the accuracy of sex determination using the statistical software solution Fordisc which derives its database and functions from the US American Forensic Database. In a comparison between metric analysis using Fordisc and morphological determination of sex, average accuracy for both sexes was 86 vs 94%, respectively, and males were identified more accurately than females. The ratio of the true test result rate to the false test result rate was not statistically different for the two methodological approaches at a significance level of 0.05 but was statistically different at a level of 0.10 (p=0.06). Possible explanations for this difference comprise different ancestry, age distribution, and socio-economic status compared to the Fordisc reference sample. It is likely that a discriminant function analysis on the basis of more similar European reference samples will lead to more valid and reliable sexing results. The use of Fordisc as a single method for the estimation of sex of recent skeletal remains in Europe cannot be recommended without additional morphological assessment and without a built-in software update based on modern European reference samples.
Study on constant-step stress accelerated life tests in white organic light-emitting diodes.
Zhang, J P; Liu, C; Chen, X; Cheng, G L; Zhou, A X
2014-11-01
In order to obtain reliability information for a white organic light-emitting diode (OLED), two constant and one step stress tests were conducted with its working current increased. The Weibull function was applied to describe the OLED life distribution, and the maximum likelihood estimation (MLE) and its iterative flow chart were used to calculate shape and scale parameters. Furthermore, the accelerated life equation was determined using the least squares method, a Kolmogorov-Smirnov test was performed to assess if the white OLED life follows a Weibull distribution, and self-developed software was used to predict the average and the median lifetimes of the OLED. The numerical results indicate that white OLED life conforms to a Weibull distribution, and that the accelerated life equation completely satisfies the inverse power law. The estimated life of a white OLED may provide significant guidelines for its manufacturers and customers. Copyright © 2014 John Wiley & Sons, Ltd.
Dehghani, Mahdieh; Shadkam, Elaheh; Ahrari, Farzaneh; Dehghani, Mahboobe
2018-04-01
Age estimation in adults is an important issue in forensic science. This study aimed to estimate the chronological age of Iranians by means of pulp/tooth area ratio (AR) of canines in digital panoramic radiographs. The sample consisted of panoramic radiographs of 271 male and female subjects aged 16-64 years. The pulp/tooth area ratio (AR) of upper and lower canines was calculated by AutoCAD software. Data were subjected to correlation and regression analysis. There was a significant and inverse correlation between age and pulp/tooth area ratio of upper and lower canines (r=-0.794 for upper canine and r=-0.282 for lower canine; p-value<0.001). Linear regression equations were derived separately for upper, lower and both canines. The mean difference between actual and estimated age using upper canine was 6.07±1.7. The results showed that the pulp/tooth area ratios of canines are a reliable method for age estimation in Iranians. The pulp/tooth area ratio of upper canine was better correlated with chronological age than that of lower canine. Copyright © 2018 Elsevier B.V. All rights reserved.
Fully decentralized estimation and control for a modular wheeled mobile robot
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mutambara, A.G.O.; Durrant-Whyte, H.F.
2000-06-01
In this paper, the problem of fully decentralized data fusion and control for a modular wheeled mobile robot (WMR) is addressed. This is a vehicle system with nonlinear kinematics, distributed multiple sensors, and nonlinear sensor models. The problem is solved by applying fully decentralized estimation and control algorithms based on the extended information filter. This is achieved by deriving a modular, decentralized kinematic model by using plane motion kinematics to obtain the forward and inverse kinematics for a generalized simple wheeled vehicle. This model is then used in the decentralized estimation and control algorithms. WMR estimation and control is thusmore » obtained locally using reduced order models with reduced communication of information between nodes is carried out after every measurement (full rate communication), the estimates and control signals obtained at each node are equivalent to those obtained by a corresponding centralized system. Transputer architecture is used as the basis for hardware and software design as it supports the extensive communication and concurrency requirements that characterize modular and decentralized systems. The advantages of a modular WMR vehicle include scalability, application flexibility, low prototyping costs, and high reliability.« less
Assessment of the Maximal Split-Half Coefficient to Estimate Reliability
ERIC Educational Resources Information Center
Thompson, Barry L.; Green, Samuel B.; Yang, Yanyun
2010-01-01
The maximal split-half coefficient is computed by calculating all possible split-half reliability estimates for a scale and then choosing the maximal value as the reliability estimate. Osburn compared the maximal split-half coefficient with 10 other internal consistency estimates of reliability and concluded that it yielded the most consistently…
ERIC Educational Resources Information Center
Morgan, Grant B.; Zhu, Min; Johnson, Robert L.; Hodge, Kari J.
2014-01-01
Common estimators of interrater reliability include Pearson product-moment correlation coefficients, Spearman rank-order correlations, and the generalizability coefficient. The purpose of this study was to examine the accuracy of estimators of interrater reliability when varying the true reliability, number of scale categories, and number of…
Building a Library Web Server on a Budget.
ERIC Educational Resources Information Center
Orr, Giles
1998-01-01
Presents a method for libraries with limited budgets to create reliable Web servers with existing hardware and free software available via the Internet. Discusses staff, hardware and software requirements, and security; outlines the assembly process. (PEN)
Enhanced CARES Software Enables Improved Ceramic Life Prediction
NASA Technical Reports Server (NTRS)
Janosik, Lesley A.
1997-01-01
The NASA Lewis Research Center has developed award-winning software that enables American industry to establish the reliability and life of brittle material (e.g., ceramic, intermetallic, graphite) structures in a wide variety of 21st century applications. The CARES (Ceramics Analysis and Reliability Evaluation of Structures) series of software is successfully used by numerous engineers in industrial, academic, and government organizations as an essential element of the structural design and material selection processes. The latest version of this software, CARES/Life, provides a general- purpose design tool that predicts the probability of failure of a ceramic component as a function of its time in service. CARES/Life was recently enhanced by adding new modules designed to improve functionality and user-friendliness. In addition, a beta version of the newly-developed CARES/Creep program (for determining the creep life of monolithic ceramic components) has just been released to selected organizations.
Expert system verification and validation study. Delivery 3A and 3B: Trip summaries
NASA Technical Reports Server (NTRS)
French, Scott
1991-01-01
Key results are documented from attending the 4th workshop on verification, validation, and testing. The most interesting part of the workshop was when representatives from the U.S., Japan, and Europe presented surveys of VV&T within their respective regions. Another interesting part focused on current efforts to define industry standards for artificial intelligence and how that might affect approaches to VV&T of expert systems. The next part of the workshop focused on VV&T methods of applying mathematical techniques to verification of rule bases and techniques for capturing information relating to the process of developing software. The final part focused on software tools. A summary is also presented of the EPRI conference on 'Methodologies, Tools, and Standards for Cost Effective Reliable Software Verification and Validation. The conference was divided into discussion sessions on the following issues: development process, automated tools, software reliability, methods, standards, and cost/benefit considerations.
Improving the Effectiveness of Program Managers
2006-05-03
Improving the Effectiveness of Program Managers Systems and Software Technology Conference Salt Lake City, Utah May 3, 2006 Presented by GAO’s...Companies’ best practices Motorola Caterpillar Toyota FedEx NCR Teradata Boeing Hughes Space and Communications Disciplined software and management...and total ownership costs Collection of metrics data to improve software reliability Technology readiness levels and design maturity Statistical
STAMPS: development and verification of swallowing kinematic analysis software.
Lee, Woo Hyung; Chun, Changmook; Seo, Han Gil; Lee, Seung Hak; Oh, Byung-Mo
2017-10-17
Swallowing impairment is a common complication in various geriatric and neurodegenerative diseases. Swallowing kinematic analysis is essential to quantitatively evaluate the swallowing motion of the oropharyngeal structures. This study aims to develop a novel swallowing kinematic analysis software, called spatio-temporal analyzer for motion and physiologic study (STAMPS), and verify its validity and reliability. STAMPS was developed in MATLAB, which is one of the most popular platforms for biomedical analysis. This software was constructed to acquire, process, and analyze the data of swallowing motion. The target of swallowing structures includes bony structures (hyoid bone, mandible, maxilla, and cervical vertebral bodies), cartilages (epiglottis and arytenoid), soft tissues (larynx and upper esophageal sphincter), and food bolus. Numerous functions are available for the spatiotemporal parameters of the swallowing structures. Testing for validity and reliability was performed in 10 dysphagia patients with diverse etiologies and using the instrumental swallowing model which was designed to mimic the motion of the hyoid bone and the epiglottis. The intra- and inter-rater reliability tests showed excellent agreement for displacement and moderate to excellent agreement for velocity. The Pearson correlation coefficients between the measured and instrumental reference values were nearly 1.00 (P < 0.001) for displacement and velocity. The Bland-Altman plots showed good agreement between the measurements and the reference values. STAMPS provides precise and reliable kinematic measurements and multiple practical functionalities for spatiotemporal analysis. The software is expected to be useful for researchers who are interested in the swallowing motion analysis.
Deep space network software cost estimation model
NASA Technical Reports Server (NTRS)
Tausworthe, R. C.
1981-01-01
A parametric software cost estimation model prepared for Deep Space Network (DSN) Data Systems implementation tasks is presented. The resource estimation model incorporates principles and data from a number of existing models. The model calibrates task magnitude and difficulty, development environment, and software technology effects through prompted responses to a set of approximately 50 questions. Parameters in the model are adjusted to fit DSN software life cycle statistics. The estimation model output scales a standard DSN Work Breakdown Structure skeleton, which is then input into a PERT/CPM system, producing a detailed schedule and resource budget for the project being planned.
Buchner, Lena; Güntert, Peter
2015-02-03
Nuclear magnetic resonance (NMR) structures are represented by bundles of conformers calculated from different randomized initial structures using identical experimental input data. The spread among these conformers indicates the precision of the atomic coordinates. However, there is as yet no reliable measure of structural accuracy, i.e., how close NMR conformers are to the "true" structure. Instead, the precision of structure bundles is widely (mis)interpreted as a measure of structural quality. Attempts to increase precision often overestimate accuracy by tight bundles of high precision but much lower accuracy. To overcome this problem, we introduce a protocol for NMR structure determination with the software package CYANA, which produces, like the traditional method, bundles of conformers in agreement with a common set of conformational restraints but with a realistic precision that is, throughout a variety of proteins and NMR data sets, a much better estimate of structural accuracy than the precision of conventional structure bundles. Copyright © 2015 Elsevier Ltd. All rights reserved.
Reliability analysis of the F-8 digital fly-by-wire system
NASA Technical Reports Server (NTRS)
Brock, L. D.; Goodman, H. A.
1981-01-01
The F-8 Digital Fly-by-Wire (DFBW) flight test program intended to provide the technology for advanced control systems, giving aircraft enhanced performance and operational capability is addressed. A detailed analysis of the experimental system was performed to estimated the probabilities of two significant safety critical events: (1) loss of primary flight control function, causing reversion to the analog bypass system; and (2) loss of the aircraft due to failure of the electronic flight control system. The analysis covers appraisal of risks due to random equipment failure, generic faults in design of the system or its software, and induced failure due to external events. A unique diagrammatic technique was developed which details the combinatorial reliability equations for the entire system, promotes understanding of system failure characteristics, and identifies the most likely failure modes. The technique provides a systematic method of applying basic probability equations and is augmented by a computer program written in a modular fashion that duplicates the structure of these equations.
MYRaf: A new Approach with IRAF for Astronomical Photometric Reduction
NASA Astrophysics Data System (ADS)
Kilic, Y.; Shameoni Niaei, M.; Özeren, F. F.; Yesilyaprak, C.
2016-12-01
In this study, the design and some developments of MYRaf software for astronomical photometric reduction are presented. MYRaf software is an easy to use, reliable, and has a fast IRAF aperture photometry GUI tools. MYRaf software is an important step for the automated software process of robotic telescopes, and uses IRAF, PyRAF, matplotlib, ginga, alipy, and Sextractor with the general-purpose and high-level programming language Python and uses the QT framework.
Analysis of key technologies for virtual instruments metrology
NASA Astrophysics Data System (ADS)
Liu, Guixiong; Xu, Qingui; Gao, Furong; Guan, Qiuju; Fang, Qiang
2008-12-01
Virtual instruments (VIs) require metrological verification when applied as measuring instruments. Owing to the software-centered architecture, metrological evaluation of VIs includes two aspects: measurement functions and software characteristics. Complexity of software imposes difficulties on metrological testing of VIs. Key approaches and technologies for metrology evaluation of virtual instruments are investigated and analyzed in this paper. The principal issue is evaluation of measurement uncertainty. The nature and regularity of measurement uncertainty caused by software and algorithms can be evaluated by modeling, simulation, analysis, testing and statistics with support of powerful computing capability of PC. Another concern is evaluation of software features like correctness, reliability, stability, security and real-time of VIs. Technologies from software engineering, software testing and computer security domain can be used for these purposes. For example, a variety of black-box testing, white-box testing and modeling approaches can be used to evaluate the reliability of modules, components, applications and the whole VI software. The security of a VI can be assessed by methods like vulnerability scanning and penetration analysis. In order to facilitate metrology institutions to perform metrological verification of VIs efficiently, an automatic metrological tool for the above validation is essential. Based on technologies of numerical simulation, software testing and system benchmarking, a framework for the automatic tool is proposed in this paper. Investigation on implementation of existing automatic tools that perform calculation of measurement uncertainty, software testing and security assessment demonstrates the feasibility of the automatic framework advanced.
Automated Estimation Of Software-Development Costs
NASA Technical Reports Server (NTRS)
Roush, George B.; Reini, William
1993-01-01
COSTMODL is automated software development-estimation tool. Yields significant reduction in risk of cost overruns and failed projects. Accepts description of software product developed and computes estimates of effort required to produce it, calendar schedule required, and distribution of effort and staffing as function of defined set of development life-cycle phases. Written for IBM PC(R)-compatible computers.
Estimating Software Effort Hours for Major Defense Acquisition Programs
ERIC Educational Resources Information Center
Wallshein, Corinne C.
2010-01-01
Software Cost Estimation (SCE) uses labor hours or effort required to conceptualize, develop, integrate, test, field, or maintain program components. Department of Defense (DoD) SCE can use initial software data parameters to project effort hours for large, software-intensive programs for contractors reporting the top levels of process maturity,…
NASA Astrophysics Data System (ADS)
Hemmings, J. C. P.; Challenor, P. G.
2012-04-01
A wide variety of different plankton system models have been coupled with ocean circulation models, with the aim of understanding and predicting aspects of environmental change. However, an ability to make reliable inferences about real-world processes from the model behaviour demands a quantitative understanding of model error that remains elusive. Assessment of coupled model output is inhibited by relatively limited observing system coverage of biogeochemical components. Any direct assessment of the plankton model is further inhibited by uncertainty in the physical state. Furthermore, comparative evaluation of plankton models on the basis of their design is inhibited by the sensitivity of their dynamics to many adjustable parameters. Parameter uncertainty has been widely addressed by calibrating models at data-rich ocean sites. However, relatively little attention has been given to quantifying uncertainty in the physical fields required by the plankton models at these sites, and tendencies in the biogeochemical properties due to the effects of horizontal processes are often neglected. Here we use model twin experiments, in which synthetic data are assimilated to estimate a system's known "true" parameters, to investigate the impact of error in a plankton model's environmental input data. The experiments are supported by a new software tool, the Marine Model Optimization Testbed, designed for rigorous analysis of plankton models in a multi-site 1-D framework. Simulated errors are derived from statistical characterizations of the mixed layer depth, the horizontal flux divergence tendencies of the biogeochemical tracers and the initial state. Plausible patterns of uncertainty in these data are shown to produce strong temporal and spatial variability in the expected simulation error variance over an annual cycle, indicating variation in the significance attributable to individual model-data differences. An inverse scheme using ensemble-based estimates of the simulation error variance to allow for this environment error performs well compared with weighting schemes used in previous calibration studies, giving improved estimates of the known parameters. The efficacy of the new scheme in real-world applications will depend on the quality of statistical characterizations of the input data. Practical approaches towards developing reliable characterizations are discussed.
Fojas, Christina L; Kim, Jieun; Minsky-Rowland, Jocelyn D; Algee-Hewitt, Bridget F B
2018-01-01
Skeletal age estimation is an integral part of the biological profile. Recent work shows how multiple-trait approaches better capture senescence as it occurs at different rates among individuals. Furthermore, a Bayesian statistical framework of analysis provides more useful age estimates. The component-scoring method of Transition Analysis (TA) may resolve many of the functional and statistical limitations of traditional phase-aging methods and is applicable to both paleodemography and forensic casework. The present study contributes to TA-research by validating TA for multiple, differently experienced observers using a collection of modern forensic skeletal cases. Five researchers independently applied TA to a random sample of 58 documented individuals from the William M. Bass Forensic Skeletal Collection, for whom knowledge of chronological age was withheld. Resulting scores were input into the ADBOU software and maximum likelihood estimates (MLEs) and 95% confidence intervals (CIs) were produced using the forensic prior. Krippendorff's alpha was used to evaluate interrater reliability and agreement. Inaccuracy and bias were measured to gauge the magnitude and direction of difference between estimated ages and chronological ages among the five observers. The majority of traits had moderate to excellent agreement among observers (≥0.6). The superior surface morphology had the least congruence (0.4), while the ventral symphyseal margin had the most (0.9) among scores. Inaccuracy was the lowest for individuals younger than 30 and the greatest for individuals over 60. Consistent over-estimation of individuals younger than 30 and under-estimation of individuals over 40 years old occurred. Individuals in their 30s showed a mixed pattern of under- and over-estimation among observers. These results support the use of the TA method by researchers of varying experience levels. Further, they validate its use on forensic cases, given the low error overall. © 2017 Wiley Periodicals, Inc.
Jha, Ashish Kumar
2015-01-01
Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.
NASA Astrophysics Data System (ADS)
Mao, Heng; Wang, Xiao; Zhao, Dazun
2009-05-01
As a wavefront sensing (WFS) tool, Baseline algorithm, which is classified as the iterative-transform algorithm of phase retrieval, estimates the phase distribution at pupil from some known PSFs at defocus planes. By using multiple phase diversities and appropriate phase unwrapping methods, this algorithm can accomplish reliable unique solution and high dynamic phase measurement. In the paper, a Baseline algorithm based wavefront sensing experiment with modification of phase unwrapping has been implemented, and corresponding Graphical User Interfaces (GUI) software has also been given. The adaptability and repeatability of Baseline algorithm have been validated in experiments. Moreover, referring to the ZYGO interferometric results, the WFS accuracy of this algorithm has been exactly calibrated.
Software Reliability Estimation under Conditions of Incomplete Information.
1979-10-01
6k) 1 I’a 1 aN+6d (k D N ae a a m a m where ae i Jl i-rnm ae Mem 0 i~m and -A.7- I pop ," -, (L 0 a o\\ a a(0 0 a) ( T n +L L0- (k0 B2 e e aL (0 -TA...zLLki2ZLK22 9o 10 LuNTINUL 97 METURN -D.7- I ,u~t(OUTLiNE H.TA(ABPeNA.T#VvRRPJJJ) .5 mEAL*b toA HLAL kAeX~ oHP #RNiAtR7#DPRZ thEAL RO a Ia$GL(hiR) Kb
Reliability Analysis for AFTI-F16 SRFCS Using ASSIST and SURE
NASA Technical Reports Server (NTRS)
Wu, N. Eva
2001-01-01
This paper reports the results of a study on reliability analysis of an AFTI-16 Self-Repairing Flight Control System (SRFCS) using software tools SURE (Semi-Markov Unreliability Range Evaluator and ASSIST (Abstract Semi-Markov Specification Interface to the SURE Tool). The purpose of the study is to investigate the potential utility of the software tools in the ongoing effort of the NASA Aviation Safety Program, where the class of systems must be extended beyond the originally intended serving class of electronic digital processors. The study concludes that SURE and ASSIST are applicable to reliability, analysis of flight control systems. They are especially efficient for sensitivity analysis that quantifies the dependence of system reliability on model parameters. The study also confirms an earlier finding on the dominant role of a parameter called a failure coverage. The paper will remark on issues related to the improvement of coverage and the optimization of redundancy level.
Reliability and availability analysis of a 10 kW@20 K helium refrigerator
NASA Astrophysics Data System (ADS)
Li, J.; Xiong, L. Y.; Liu, L. Q.; Wang, H. R.; Wang, B. M.
2017-02-01
A 10 kW@20 K helium refrigerator has been established in the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. To evaluate and improve this refrigerator’s reliability and availability, a reliability and availability analysis is performed. According to the mission profile of this refrigerator, a functional analysis is performed. The failure data of the refrigerator components are collected and failure rate distributions are fitted by software Weibull++ V10.0. A Failure Modes, Effects & Criticality Analysis (FMECA) is performed and the critical components with higher risks are pointed out. Software BlockSim V9.0 is used to calculate the reliability and the availability of this refrigerator. The result indicates that compressors, turbine and vacuum pump are the critical components and the key units of this refrigerator. The mitigation actions with respect to design, testing, maintenance and operation are proposed to decrease those major and medium risks.
Bayesian Software Health Management for Aircraft Guidance, Navigation, and Control
NASA Technical Reports Server (NTRS)
Schumann, Johann; Mbaya, Timmy; Menghoel, Ole
2011-01-01
Modern aircraft, both piloted fly-by-wire commercial aircraft as well as UAVs, more and more depend on highly complex safety critical software systems with many sensors and computer-controlled actuators. Despite careful design and V&V of the software, severe incidents have happened due to malfunctioning software. In this paper, we discuss the use of Bayesian networks (BNs) to monitor the health of the on-board software and sensor system, and to perform advanced on-board diagnostic reasoning. We will focus on the approach to develop reliable and robust health models for the combined software and sensor systems.
Application of Kingview and PLC in friction durability test system
NASA Astrophysics Data System (ADS)
Gao, Yinhan; Cui, Jing; Yang, Kaiyu; Ke, Hui; Song, Bing
2013-01-01
Using PLC and Kingview software, a friction durability test system is designed. The overall program, hardware configuration, software structure and monitoring interface are described in detail. PLC ensures the stability of data acquisition, and the KingView software makes the HMI easy to manipulate. The practical application shows that the proposed system is cheap, economical and highly reliable.
Technology Infusion of CodeSonar into the Space Network Ground Segment (RII07)
NASA Technical Reports Server (NTRS)
Benson, Markland
2008-01-01
The NASA Software Assurance Research Program (in part) performs studies as to the feasibility of technologies for improving the safety, quality, reliability, cost, and performance of NASA software. This study considers the application of commercial automated source code analysis tools to mission critical ground software that is in the operations and sustainment portion of the product lifecycle.
Software Cuts Homebuilding Costs, Increases Energy Efficiency
NASA Technical Reports Server (NTRS)
2015-01-01
To sort out the best combinations of technologies for a crewed mission to Mars, NASA Headquarters awarded grants to MIT's Department of Aeronautics and Astronautics to develop an algorithm-based software tool that highlights the most reliable and cost-effective options. Utilizing the software, Professor Edward Crawley founded Cambridge, Massachussetts-based Ekotrope, which helps homebuilders choose cost- and energy-efficient floor plans and materials.
NASA Technical Reports Server (NTRS)
Green, Scott; Kouchakdjian, Ara; Basili, Victor; Weidow, David
1990-01-01
This case study analyzes the application of the cleanroom software development methodology to the development of production software at the NASA/Goddard Space Flight Center. The cleanroom methodology emphasizes human discipline in program verification to produce reliable software products that are right the first time. Preliminary analysis of the cleanroom case study shows that the method can be applied successfully in the FDD environment and may increase staff productivity and product quality. Compared to typical Software Engineering Laboratory (SEL) activities, there is evidence of lower failure rates, a more complete and consistent set of inline code documentation, a different distribution of phase effort activity, and a different growth profile in terms of lines of code developed. The major goals of the study were to: (1) assess the process used in the SEL cleanroom model with respect to team structure, team activities, and effort distribution; (2) analyze the products of the SEL cleanroom model and determine the impact on measures of interest, including reliability, productivity, overall life-cycle cost, and software quality; and (3) analyze the residual products in the application of the SEL cleanroom model, such as fault distribution, error characteristics, system growth, and computer usage.
Fortin, Carole; Feldman, Debbie Ehrmann; Cheriet, Farida; Gravel, Denis; Gauthier, Frédérique; Labelle, Hubert
2012-03-01
To determine overall, test-retest and inter-rater reliability of posture indices among persons with idiopathic scoliosis. A reliability study using two raters and two test sessions. Tertiary care paediatric centre. Seventy participants aged between 10 and 20 years with different types of idiopathic scoliosis (Cobb angle 15 to 60°) were recruited from the scoliosis clinic. Based on the XY co-ordinates of natural reference points (e.g., eyes) as well as markers placed on several anatomical landmarks, 32 angular and linear posture indices taken from digital photographs in the standing position were calculated from a specially developed software program. Generalisability theory served to estimate the reliability and standard error of measurement (SEM) for the overall, test-retest and inter-rater designs. Bland and Altman's method was also used to document agreement between sessions and raters. In the random design, dependability coefficients demonstrated a moderate level of reliability for six posture indices (ϕ=0.51 to 0.72) and a good level of reliability for 26 posture indices out of 32 (ϕ≥0.79). Error attributable to marker placement was negligible for most indices. Limits of agreement and SEM values were larger for shoulder protraction, trunk list, Q angle, cervical lordosis and scoliosis angles. The most reproducible indices were waist angles and knee valgus and varus. Posture can be assessed in a global fashion from photographs in persons with idiopathic scoliosis. Despite the good reliability of marker placement, other studies are needed to minimise measurement errors in order to provide a suitable tool for monitoring change in posture over time. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Jackson, Michael; Blatt, Stephan; Holub, Kirk
2015-04-01
In April of 2014, NOAA/OAR/ESRL Global Systems Division (GSD) and Trimble, in collaboration with Earth Networks, Inc. (ENI) signed a Cooperative Research and Development Agreement (CRADA) to transfer the existing NOAA GPS-Met Data Acquisition and Processing System (GPS-Met DAPS) technology to a commercial Trimble/ENI partnership. NOAA's GPS-Met DAPS is currently operated in a pseudo-operational mode but has proven highly reliable and running at over 95% uptime. The DAPS uses the GAMIT software to ingest dual frequency carrier phase GPS/GNSS observations and ancillary information such as real-time satellite orbits to estimate the zenith-scaled tropospheric (ZTD) signal delays and, where surface MET data are available, retrieve integrated precipitable water vapor (PWV). The NOAA data and products are made available to end users in near real-time. The Trimble/ENI partnership will use the Trimble Pivot™ software with the Atmosphere App to calculate zenith tropospheric (ZTD), tropospheric slant delay, and integrated precipitable water vapor (PWV). Evaluation of the Trimble software is underway starting with a comparison of ZTD and PWV values determined from four sub networks of GPS stations located 1. near NOAA Radiosonde Observation (Upper-Air Observation) launch sites; 2. Stations with low terrain/high moisture variability (Gulf Coast); 3. Stations with high terrain/low moisture variability (Southern California); and 4. Stations with high terrain/high moisture variability (high terrain variability elev. > 1000m). For each network GSD and T/ENI run the same stations for 30 days, compare results, and perform an evaluation of the long-term solution accuracy, precision and reliability. Metrics for success include T/ENI PWV estimates within 1.5 mm of ESRL/GSD's estimates 95% of the time (ZTD uncertainty of less than 10 mm 95% of the time). The threshold for allowable variations in ZTD between NOAA GPS-Met and T/ENI processing are 10mm. The CRADA 1&2 Trimble processing show a variation of 4±2mm and 3±8mm respectively. The threshold for allowable variations in PWV between NOAA GPS-Met and T/ENI processing are 15mm. The CRADA 1&2 Trimble processing show a variation of 2±4mm and 10±13 respectively. The T/ENI PWV and ZTD values meet and exceed the requirements outlined in the CRADA for the first two networks processed. T/ENI Partnership brings a footprint of GNSS and meteorological stations that could significantly enhance the latency, temporal, and geographic density of ZTD and PWV over the US and Europe. We will provide a brief overview of the Trimble Pivot™ software and the Atmosphere App and present results from further testing along with a timeline for the transition of the GPS-Met DAPS to an operational commercial service.
Software cost/resource modeling: Deep space network software cost estimation model
NASA Technical Reports Server (NTRS)
Tausworthe, R. J.
1980-01-01
A parametric software cost estimation model prepared for JPL deep space network (DSN) data systems implementation tasks is presented. The resource estimation model incorporates principles and data from a number of existing models, such as those of the General Research Corporation, Doty Associates, IBM (Walston-Felix), Rome Air Force Development Center, University of Maryland, and Rayleigh-Norden-Putnam. The model calibrates task magnitude and difficulty, development environment, and software technology effects through prompted responses to a set of approximately 50 questions. Parameters in the model are adjusted to fit JPL software lifecycle statistics. The estimation model output scales a standard DSN work breakdown structure skeleton, which is then input to a PERT/CPM system, producing a detailed schedule and resource budget for the project being planned.
Improving a data-acquisition software system with abstract data type components
NASA Technical Reports Server (NTRS)
Howard, S. D.
1990-01-01
Abstract data types and object-oriented design are active research areas in computer science and software engineering. Much of the interest is aimed at new software development. Abstract data type packages developed for a discontinued software project were used to improve a real-time data-acquisition system under maintenance. The result saved effort and contributed to a significant improvement in the performance, maintainability, and reliability of the Goldstone Solar System Radar Data Acquisition System.
Transition of NOAA's GPS-Met Data Acquisition and Processing System to the Commercial Sector
NASA Astrophysics Data System (ADS)
Jackson, M. E.; Holub, K.; Callahan, W.; Blatt, S.
2014-12-01
In April of 2014, NOAA/OAR/ESRL Global Systems Division (GSD) and Trimble, in collaboration with Earth Networks, Inc. (ENI) signed a Cooperative Research and Development Agreement (CRADA) to transfer the existing NOAA GPS-Met Data Acquisition and Processing System (GPS-Met DAPS) technology to a commercial Trimble/ENI partnership. NOAA's GPS-Met DAPS is currently operated in a pseudo-operational mode but has proven highly reliable and running at over 95% uptime. The DAPS uses the GAMIT software to ingest dual frequency carrier phase GPS/GNSS observations and ancillary information such as real-time satellite orbits to estimate the zenith-scaled tropospheric (ZTD) signal delays and, where surface MET data are available, retrieve integrated precipitable water vapor (PWV). The NOAA data and products are made available to end users in near real-time. The Trimble/ENI partnership will use the Trimble Pivot™ software with the Atmosphere App to calculate zenith tropospheric (ZTD), tropospheric slant delay, and integrated precipitable water vapor (PWV). Evaluation of the Trimble software is underway starting with a comparison of ZTD and PWV values determined from GPS stations located near NOAA Radiosonde Observation (Upper-Air Observation) launch sites. A success metric was established that requires Trimble's PWV estimates to match ESRL/GSD's to within 1.5 mm 95% of the time, which corresponds to a ZTD uncertainty of less than 10 mm 95% of the time. Initial results indicate that Trimble/ENI data meet and exceed the ZTD metric, but for some stations PWV estimates are out of specification. These discrepancies are primarily due to how offsets between MET and GPS stations are handled and are easily resolved. Additional test networks are proposed that include low terrain/high moisture variability stations, high terrain/low moisture variability stations, as well as high terrain/high moisture variability stations. We will present results from further testing along with a timeline for the transition of the GPS-Met DAPS to an operational commercial service.
Storage system software solutions for high-end user needs
NASA Technical Reports Server (NTRS)
Hogan, Carole B.
1992-01-01
Today's high-end storage user is one that requires rapid access to a reliable terabyte-capacity storage system running in a distributed environment. This paper discusses conventional storage system software and concludes that this software, designed for other purposes, cannot meet high-end storage requirements. The paper also reviews the philosophy and design of evolving storage system software. It concludes that this new software, designed with high-end requirements in mind, provides the potential for solving not only the storage needs of today but those of the foreseeable future as well.
Functional description of the ISIS system
NASA Technical Reports Server (NTRS)
Berman, W. J.
1979-01-01
Development of software for avionic and aerospace applications (flight software) is influenced by a unique combination of factors which includes: (1) length of the life cycle of each project; (2) necessity for cooperation between the aerospace industry and NASA; (3) the need for flight software that is highly reliable; (4) the increasing complexity and size of flight software; and (5) the high quality of the programmers and the tightening of project budgets. The interactive software invocation system (ISIS) which is described is designed to overcome the problems created by this combination of factors.
A software upgrade method for micro-electronics medical implants.
Cao, Yang; Hao, Hongwei; Xue, Lin; Li, Luming; Ma, Bozhi
2006-01-01
A software upgrade method for micro-electronics medical implants is designed to enhance the devices' function or renew the software if there are some bugs found, the software updating or some memory units disabled. The implants needn't be replaced by operations if the faults can be corrected through reprogramming, which reduces the patients' pain and improves the safety effectively. This paper introduces the software upgrade method using in-application programming (IAP) and emphasizes how to insure the system, especially the implanted part's reliability and stability while upgrading.
From LPF to eLISA: new approach in payload software
NASA Astrophysics Data System (ADS)
Gesa, Ll.; Martin, V.; Conchillo, A.; Ortega, J. A.; Mateos, I.; Torrents, A.; Lopez-Zaragoza, J. P.; Rivas, F.; Lloro, I.; Nofrarias, M.; Sopuerta, CF.
2017-05-01
eLISA will be the first observatory in space to explore the Gravitational Universe. It will gather revolutionary information about the dark universe. This implies a robust and reliable embedded control software and hardware working together. With the lessons learnt with the LISA Pathfinder payload software as baseline, we will introduce in this short article the key concepts and new approaches that our group is working on in terms of software: multiprocessor, self-modifying-code strategies, 100% hardware and software monitoring, embedded scripting, Time and Space Partition among others.
Industry Software Trustworthiness Criterion Research Based on Business Trustworthiness
NASA Astrophysics Data System (ADS)
Zhang, Jin; Liu, Jun-fei; Jiao, Hai-xing; Shen, Yi; Liu, Shu-yuan
To industry software Trustworthiness problem, an idea aiming to business to construct industry software trustworthiness criterion is proposed. Based on the triangle model of "trustworthy grade definition-trustworthy evidence model-trustworthy evaluating", the idea of business trustworthiness is incarnated from different aspects of trustworthy triangle model for special industry software, power producing management system (PPMS). Business trustworthiness is the center in the constructed industry trustworthy software criterion. Fusing the international standard and industry rules, the constructed trustworthy criterion strengthens the maneuverability and reliability. Quantitive evaluating method makes the evaluating results be intuitionistic and comparable.
Khoshgoftaar, T M; Allen, E B; Hudepohl, J P; Aud, S J
1997-01-01
Society relies on telecommunications to such an extent that telecommunications software must have high reliability. Enhanced measurement for early risk assessment of latent defects (EMERALD) is a joint project of Nortel and Bell Canada for improving the reliability of telecommunications software products. This paper reports a case study of neural-network modeling techniques developed for the EMERALD system. The resulting neural network is currently in the prototype testing phase at Nortel. Neural-network models can be used to identify fault-prone modules for extra attention early in development, and thus reduce the risk of operational problems with those modules. We modeled a subset of modules representing over seven million lines of code from a very large telecommunications software system. The set consisted of those modules reused with changes from the previous release. The dependent variable was membership in the class of fault-prone modules. The independent variables were principal components of nine measures of software design attributes. We compared the neural-network model with a nonparametric discriminant model and found the neural-network model had better predictive accuracy.
Design and validation of an automated hydrostatic weighing system.
McClenaghan, B A; Rocchio, L
1986-08-01
The purpose of this study was to design and evaluate the validity of an automated technique to assess body density using a computerized hydrostatic weighing system. An existing hydrostatic tank was modified and interfaced with a microcomputer equipped with an analog-to-digital converter. Software was designed to input variables, control the collection of data, calculate selected measurements, and provide a summary of the results of each session. Validity of the data obtained utilizing the automated hydrostatic weighing system was estimated by: evaluating the reliability of the transducer/computer interface to measure objects of known underwater weight; comparing the data against a criterion measure; and determining inter-session subject reliability. Values obtained from the automated system were found to be highly correlated with known underwater weights (r = 0.99, SEE = 0.0060 kg). Data concurrently obtained utilizing the automated system and a manual chart recorder were also found to be highly correlated (r = 0.99, SEE = 0.0606 kg). Inter-session subject reliability was determined utilizing data collected on subjects (N = 16) tested on two occasions approximately 24 h apart. Correlations revealed high relationships between measures of underwater weight (r = 0.99, SEE = 0.1399 kg) and body density (r = 0.98, SEE = 0.00244 g X cm-1). Results indicate that a computerized hydrostatic weighing system is a valid and reliable method for determining underwater weight.
Quantitative Measures for Software Independent Verification and Validation
NASA Technical Reports Server (NTRS)
Lee, Alice
1996-01-01
As software is maintained or reused, it undergoes an evolution which tends to increase the overall complexity of the code. To understand the effects of this, we brought in statistics experts and leading researchers in software complexity, reliability, and their interrelationships. These experts' project has resulted in our ability to statistically correlate specific code complexity attributes, in orthogonal domains, to errors found over time in the HAL/S flight software which flies in the Space Shuttle. Although only a prototype-tools experiment, the result of this research appears to be extendable to all other NASA software, given appropriate data similar to that logged for the Shuttle onboard software. Our research has demonstrated that a more complete domain coverage can be mathematically demonstrated with the approach we have applied, thereby ensuring full insight into the cause-and-effects relationship between the complexity of a software system and the fault density of that system. By applying the operational profile we can characterize the dynamic effects of software path complexity under this same approach We now have the ability to measure specific attributes which have been statistically demonstrated to correlate to increased error probability, and to know which actions to take, for each complexity domain. Shuttle software verifiers can now monitor the changes in the software complexity, assess the added or decreased risk of software faults in modified code, and determine necessary corrections. The reports, tool documentation, user's guides, and new approach that have resulted from this research effort represent advances in the state of the art of software quality and reliability assurance. Details describing how to apply this technique to other NASA code are contained in this document.
FreeContact: fast and free software for protein contact prediction from residue co-evolution.
Kaján, László; Hopf, Thomas A; Kalaš, Matúš; Marks, Debora S; Rost, Burkhard
2014-03-26
20 years of improved technology and growing sequences now renders residue-residue contact constraints in large protein families through correlated mutations accurate enough to drive de novo predictions of protein three-dimensional structure. The method EVfold broke new ground using mean-field Direct Coupling Analysis (EVfold-mfDCA); the method PSICOV applied a related concept by estimating a sparse inverse covariance matrix. Both methods (EVfold-mfDCA and PSICOV) are publicly available, but both require too much CPU time for interactive applications. On top, EVfold-mfDCA depends on proprietary software. Here, we present FreeContact, a fast, open source implementation of EVfold-mfDCA and PSICOV. On a test set of 140 proteins, FreeContact was almost eight times faster than PSICOV without decreasing prediction performance. The EVfold-mfDCA implementation of FreeContact was over 220 times faster than PSICOV with negligible performance decrease. EVfold-mfDCA was unavailable for testing due to its dependency on proprietary software. FreeContact is implemented as the free C++ library "libfreecontact", complete with command line tool "freecontact", as well as Perl and Python modules. All components are available as Debian packages. FreeContact supports the BioXSD format for interoperability. FreeContact provides the opportunity to compute reliable contact predictions in any environment (desktop or cloud).
Choi, D J; Park, H
2001-11-01
For control and automation of biological treatment processes, lack of reliable on-line sensors to measure water quality parameters is one of the most important problems to overcome. Many parameters cannot be measured directly with on-line sensors. The accuracy of existing hardware sensors is also not sufficient and maintenance problems such as electrode fouling often cause trouble. This paper deals with the development of software sensor techniques that estimate the target water quality parameter from other parameters using the correlation between water quality parameters. We focus our attention on the preprocessing of noisy data and the selection of the best model feasible to the situation. Problems of existing approaches are also discussed. We propose a hybrid neural network as a software sensor inferring wastewater quality parameter. Multivariate regression, artificial neural networks (ANN), and a hybrid technique that combines principal component analysis as a preprocessing stage are applied to data from industrial wastewater processes. The hybrid ANN technique shows an enhancement of prediction capability and reduces the overfitting problem of neural networks. The result shows that the hybrid ANN technique can be used to extract information from noisy data and to describe the nonlinearity of complex wastewater treatment processes.
New Results in Software Model Checking and Analysis
NASA Technical Reports Server (NTRS)
Pasareanu, Corina S.
2010-01-01
This introductory article surveys new techniques, supported by automated tools, for the analysis of software to ensure reliability and safety. Special focus is on model checking techniques. The article also introduces the five papers that are enclosed in this special journal volume.
NASA Technical Reports Server (NTRS)
Eichenlaub, Carl T.; Harper, C. Douglas; Hird, Geoffrey
1993-01-01
Life-critical applications warrant a higher level of software reliability than has yet been achieved. Since it is not certain that traditional methods alone can provide the required ultra reliability, new methods should be examined as supplements or replacements. This paper describes a mathematical counterpart to the traditional process of empirical testing. ORA's Penelope verification system is demonstrated as a tool for evaluating the correctness of Ada software. Grady Booch's Ada calendar utility package, obtained through NASA, was specified in the Larch/Ada language. Formal verification in the Penelope environment established that many of the package's subprograms met their specifications. In other subprograms, failed attempts at verification revealed several errors that had escaped detection by testing.
U.S. ENVIRONMENTAL PROTECTION AGENCY'S LANDFILL GAS EMISSION MODEL (LANDGEM)
The paper discusses EPA's available software for estimating landfill gas emissions. This software is based on a first-order decomposition rate equation using empirical data from U.S. landfills. The software provides a relatively simple approach to estimating landfill gas emissi...
The Toxicity Estimation Software Tool (T.E.S.T.)
The Toxicity Estimation Software Tool (T.E.S.T.) has been developed to estimate toxicological values for aquatic and mammalian species considering acute and chronic endpoints for screening purposes within TSCA and REACH programs.
Logic Model Checking of Unintended Acceleration Claims in Toyota Vehicles
NASA Technical Reports Server (NTRS)
Gamble, Ed
2012-01-01
Part of the US Department of Transportation investigation of Toyota sudden unintended acceleration (SUA) involved analysis of the throttle control software, JPL Laboratory for Reliable Software applied several techniques including static analysis and logic model checking, to the software; A handful of logic models were build, Some weaknesses were identified; however, no cause for SUA was found; The full NASA report includes numerous other analyses
Reliability Problems of the Datum: Solutions for Questionnaire Responses.
ERIC Educational Resources Information Center
Bastick, Tony
Questionnaires often ask for estimates, and these estimates are given with different reliabilities. It is difficult to know the different reliabilities of single estimates and to take these into account in subsequent analyses. This paper contains a practical example to show that not taking the reliability of different responses into account can…
Use of Internal Consistency Coefficients for Estimating Reliability of Experimental Tasks Scores
Green, Samuel B.; Yang, Yanyun; Alt, Mary; Brinkley, Shara; Gray, Shelley; Hogan, Tiffany; Cowan, Nelson
2017-01-01
Reliabilities of scores for experimental tasks are likely to differ from one study to another to the extent that the task stimuli change, the number of trials varies, the type of individuals taking the task changes, the administration conditions are altered, or the focal task variable differs. Given reliabilities vary as a function of the design of these tasks and the characteristics of the individuals taking them, making inferences about the reliability of scores in an ongoing study based on reliability estimates from prior studies is precarious. Thus, it would be advantageous to estimate reliability based on data from the ongoing study. We argue that internal consistency estimates of reliability are underutilized for experimental task data and in many applications could provide this information using a single administration of a task. We discuss different methods for computing internal consistency estimates with a generalized coefficient alpha and the conditions under which these estimates are accurate. We illustrate use of these coefficients using data for three different tasks. PMID:26546100
Improvement in Visual Target Tracking for a Mobile Robot
NASA Technical Reports Server (NTRS)
Kim, Won; Ansar, Adnan; Madison, Richard
2006-01-01
In an improvement of the visual-target-tracking software used aboard a mobile robot (rover) of the type used to explore the Martian surface, an affine-matching algorithm has been replaced by a combination of a normalized- cross-correlation (NCC) algorithm and a template-image-magnification algorithm. Although neither NCC nor template-image magnification is new, the use of both of them to increase the degree of reliability with which features can be matched is new. In operation, a template image of a target is obtained from a previous rover position, then the magnification of the template image is based on the estimated change in the target distance from the previous rover position to the current rover position (see figure). For this purpose, the target distance at the previous rover position is determined by stereoscopy, while the target distance at the current rover position is calculated from an estimate of the current pose of the rover. The template image is then magnified by an amount corresponding to the estimated target distance to obtain a best template image to match with the image acquired at the current rover position.
Farkas, Árpád; Balásházy, Imre
2015-04-01
A more exact determination of dose conversion factors associated with radon progeny inhalation was possible due to the advancements in epidemiological health risk estimates in the last years. The enhancement of computational power and the development of numerical techniques allow computing dose conversion factors with increasing reliability. The objective of this study was to develop an integrated model and software based on a self-developed airway deposition code, an own bronchial dosimetry model and the computational methods accepted by International Commission on Radiological Protection (ICRP) to calculate dose conversion coefficients for different exposure conditions. The model was tested by its application for exposure and breathing conditions characteristic of mines and homes. The dose conversion factors were 8 and 16 mSv WLM(-1) for homes and mines when applying a stochastic deposition model combined with the ICRP dosimetry model (named PM-A model), and 9 and 17 mSv WLM(-1) when applying the same deposition model combined with authors' bronchial dosimetry model and the ICRP bronchiolar and alveolar-interstitial dosimetry model (called PM-B model). User friendly software for the computation of dose conversion factors has also been developed. The software allows one to compute conversion factors for a large range of exposure and breathing parameters and to perform sensitivity analyses. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Reynolds, Michelle H.; Brinck, Kevin W.; Laniawe, Leona
2011-01-01
To improve the Laysan Teal population estimates, we recommend changes to the monitoring protocol. Additional years of data are needed to quantify inter-annual seasonal detection probabilities, which may allow the use of standardized direct counts as an unbiased index of population size. Survey protocols should be enhanced through frequent resights, regular survey intervals, and determining reliable standards to detect catastrophic declines and annual changes in adult abundance. In late 2009 to early 2010, 68% of the population was marked with unique color band combinations. This allowed for potentially accurate adult population estimates and survival estimates without the need to mark new birds in 2010, 2011, and possibly 2012. However, efforts should be made to replace worn or illegible bands so birds can be identified in future surveys. It would be valuable to develop more sophisticated population size and survival models using Program MARK, a state-of-the-art software package which uses likelihood models to analyze mark-recapture data. This would allow for more reliable adult population and survival estimates to compare with the ―source‖ Laysan Teal population on Laysan Island. These models will require additional years of resight data (> 1 year) and, in some cases, an intensive annual effort of marking and recapture. Because data indicate standardized all-wetland counts are a poor index of abundance, monitoring efforts could be improved by expanding resight surveys to include all wetlands, discontinuing the all-wetland counts, and reallocating some of the wetland count effort to collect additional opportunistic resights. Approximately two years of additional bimonthly surveys are needed to validate the direct count as an appropriate index of population abundance. Additional years of individual resight data will allow estimates of adult population size, as specified in recovery criteria, and to track species population dynamics at Midway Atoll.
Ramsthaler, Frank; Kettner, Mattias; Verhoff, Marcel A
2014-01-01
In forensic anthropological casework, estimating age-at-death is key to profiling unknown skeletal remains. The aim of this study was to examine the reliability of a new, simple, fast, and inexpensive digital odontological method for age-at-death estimation. The method is based on the original Lamendin method, which is a widely used technique in the repertoire of odontological aging methods in forensic anthropology. We examined 129 single root teeth employing a digital camera and imaging software for the measurement of the luminance of the teeth's translucent root zone. Variability in luminance detection was evaluated using statistical technical error of measurement analysis. The method revealed stable values largely unrelated to observer experience, whereas requisite formulas proved to be camera-specific and should therefore be generated for an individual recording setting based on samples of known chronological age. Multiple regression analysis showed a highly significant influence of the coefficients of the variables "arithmetic mean" and "standard deviation" of luminance for the regression formula. For the use of this primer multivariate equation for age-at-death estimation in casework, a standard error of the estimate of 6.51 years was calculated. Step-by-step reduction of the number of embedded variables to linear regression analysis employing the best contributor "arithmetic mean" of luminance yielded a regression equation with a standard error of 6.72 years (p < 0.001). The results of this study not only support the premise of root translucency as an age-related phenomenon, but also demonstrate that translucency reflects a number of other influencing factors in addition to age. This new digital measuring technique of the zone of dental root luminance can broaden the array of methods available for estimating chronological age, and furthermore facilitate measurement and age classification due to its low dependence on observer experience.
Di Nardo, Francesco; Mengoni, Michele; Morettini, Micaela
2013-05-01
Present study provides a novel MATLAB-based parameter estimation procedure for individual assessment of hepatic insulin degradation (HID) process from standard frequently-sampled intravenous glucose tolerance test (FSIGTT) data. Direct access to the source code, offered by MATLAB, enabled us to design an optimization procedure based on the alternating use of Gauss-Newton's and Levenberg-Marquardt's algorithms, which assures the full convergence of the process and the containment of computational time. Reliability was tested by direct comparison with the application, in eighteen non-diabetic subjects, of well-known kinetic analysis software package SAAM II, and by application on different data. Agreement between MATLAB and SAAM II was warranted by intraclass correlation coefficients ≥0.73; no significant differences between corresponding mean parameter estimates and prediction of HID rate; and consistent residual analysis. Moreover, MATLAB optimization procedure resulted in a significant 51% reduction of CV% for the worst-estimated parameter by SAAM II and in maintaining all model-parameter CV% <20%. In conclusion, our MATLAB-based procedure was suggested as a suitable tool for the individual assessment of HID process. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Software Cost-Estimation Model
NASA Technical Reports Server (NTRS)
Tausworthe, R. C.
1985-01-01
Software Cost Estimation Model SOFTCOST provides automated resource and schedule model for software development. Combines several cost models found in open literature into one comprehensive set of algorithms. Compensates for nearly fifty implementation factors relative to size of task, inherited baseline, organizational and system environment and difficulty of task.
ToxPredictor: a Toxicity Estimation Software Tool
The Computational Toxicology Team within the National Risk Management Research Laboratory has developed a software tool that will allow the user to estimate the toxicity for a variety of endpoints (such as acute aquatic toxicity). The software tool is coded in Java and can be ac...
NASA Technical Reports Server (NTRS)
Bean, E. E.; Bloomquist, C. E.
1972-01-01
A summary of the KSC program for investigating the reliability aspects of the ground support activities is presented. An analysis of unsatisfactory condition reports (RC), and the generation of reliability assessment of components based on the URC are discussed along with the design considerations for attaining reliable real time hardware/software configurations.
Toxicity Estimation Software Tool (TEST)
The Toxicity Estimation Software Tool (TEST) was developed to allow users to easily estimate the toxicity of chemicals using Quantitative Structure Activity Relationships (QSARs) methodologies. QSARs are mathematical models used to predict measures of toxicity from the physical c...
Wu, Zhao; Xiong, Naixue; Huang, Yannong; Xu, Degang; Hu, Chunyang
2015-01-01
The services composition technology provides flexible methods for building service composition applications (SCAs) in wireless sensor networks (WSNs). The high reliability and high performance of SCAs help services composition technology promote the practical application of WSNs. The optimization methods for reliability and performance used for traditional software systems are mostly based on the instantiations of software components, which are inapplicable and inefficient in the ever-changing SCAs in WSNs. In this paper, we consider the SCAs with fault tolerance in WSNs. Based on a Universal Generating Function (UGF) we propose a reliability and performance model of SCAs in WSNs, which generalizes a redundancy optimization problem to a multi-state system. Based on this model, an efficient optimization algorithm for reliability and performance of SCAs in WSNs is developed based on a Genetic Algorithm (GA) to find the optimal structure of SCAs with fault-tolerance in WSNs. In order to examine the feasibility of our algorithm, we have evaluated the performance. Furthermore, the interrelationships between the reliability, performance and cost are investigated. In addition, a distinct approach to determine the most suitable parameters in the suggested algorithm is proposed. PMID:26561818
Issues in NASA Program and Project Management: Focus on Project Planning and Scheduling
NASA Technical Reports Server (NTRS)
Hoffman, Edward J. (Editor); Lawbaugh, William M. (Editor)
1997-01-01
Topics addressed include: Planning and scheduling training for working project teams at NASA, overview of project planning and scheduling workshops, project planning at NASA, new approaches to systems engineering, software reliability assessment, and software reuse in wind tunnel control systems.
A high order approach to flight software development and testing
NASA Technical Reports Server (NTRS)
Steinbacher, J.
1981-01-01
The use of a software development facility is discussed as a means of producing a reliable and maintainable ECS software system, and as a means of providing efficient use of the ECS hardware test facility. Principles applied to software design are given, including modularity, abstraction, hiding, and uniformity. The general objectives of each phase of the software life cycle are also given, including testing, maintenance, code development, and requirement specifications. Software development facility tools are summarized, and tool deficiencies recognized in the code development and testing phases are considered. Due to limited lab resources, the functional simulation capabilities may be indispensable in the testing phase.
Detection of faults and software reliability analysis
NASA Technical Reports Server (NTRS)
Knight, John C.
1987-01-01
Multi-version or N-version programming is proposed as a method of providing fault tolerance in software. The approach requires the separate, independent preparation of multiple versions of a piece of software for some application. These versions are executed in parallel in the application environment; each receives identical inputs and each produces its version of the required outputs. The outputs are collected by a voter and, in principle, they should all be the same. In practice there may be some disagreement. If this occurs, the results of the majority are taken to be the correct output, and that is the output used by the system. A total of 27 programs were produced. Each of these programs was then subjected to one million randomly-generated test cases. The experiment yielded a number of programs containing faults that are useful for general studies of software reliability as well as studies of N-version programming. Fault tolerance through data diversity and analytic models of comparison testing are discussed.
Verification and Validation in a Rapid Software Development Process
NASA Technical Reports Server (NTRS)
Callahan, John R.; Easterbrook, Steve M.
1997-01-01
The high cost of software production is driving development organizations to adopt more automated design and analysis methods such as rapid prototyping, computer-aided software engineering (CASE) tools, and high-level code generators. Even developers of safety-critical software system have adopted many of these new methods while striving to achieve high levels Of quality and reliability. While these new methods may enhance productivity and quality in many cases, we examine some of the risks involved in the use of new methods in safety-critical contexts. We examine a case study involving the use of a CASE tool that automatically generates code from high-level system designs. We show that while high-level testing on the system structure is highly desirable, significant risks exist in the automatically generated code and in re-validating releases of the generated code after subsequent design changes. We identify these risks and suggest process improvements that retain the advantages of rapid, automated development methods within the quality and reliability contexts of safety-critical projects.
Healthcare software assurance.
Cooper, Jason G; Pauley, Keith A
2006-01-01
Software assurance is a rigorous, lifecycle phase-independent set of activities which ensure completeness, safety, and reliability of software processes and products. This is accomplished by guaranteeing conformance to all requirements, standards, procedures, and regulations. These assurance processes are even more important when coupled with healthcare software systems, embedded software in medical instrumentation, and other healthcare-oriented life-critical systems. The current Food and Drug Administration (FDA) regulatory requirements and guidance documentation do not address certain aspects of complete software assurance activities. In addition, the FDA's software oversight processes require enhancement to include increasingly complex healthcare systems such as Hospital Information Systems (HIS). The importance of complete software assurance is introduced, current regulatory requirements and guidance discussed, and the necessity for enhancements to the current processes shall be highlighted.
Cooper, Jason G.; Pauley, Keith A.
2006-01-01
Software assurance is a rigorous, lifecycle phase-independent set of activities which ensure completeness, safety, and reliability of software processes and products. This is accomplished by guaranteeing conformance to all requirements, standards, procedures, and regulations. These assurance processes are even more important when coupled with healthcare software systems, embedded software in medical instrumentation, and other healthcare-oriented life-critical systems. The current Food and Drug Administration (FDA) regulatory requirements and guidance documentation do not address certain aspects of complete software assurance activities. In addition, the FDA’s software oversight processes require enhancement to include increasingly complex healthcare systems such as Hospital Information Systems (HIS). The importance of complete software assurance is introduced, current regulatory requirements and guidance discussed, and the necessity for enhancements to the current processes shall be highlighted. PMID:17238324
Duan, Yuanyuan; Gonzalez, Jorge A; Kulkarni, Pratim A; Nagy, William W; Griggs, Jason A
2018-06-16
To validate the fatigue lifetime of a reduced-diameter dental implant system predicted by three-dimensional finite element analysis (FEA) by testing physical implant specimens using an accelerated lifetime testing (ALT) strategy with the apparatus specified by ISO 14801. A commercially-available reduced-diameter titanium dental implant system (Straumann Standard Plus NN) was digitized using a micro-CT scanner. Axial slices were processed using an interactive medical image processing software (Mimics) to create 3D models. FEA analysis was performed in ABAQUS, and fatigue lifetime was predicted using fe-safe ® software. The same implant specimens (n=15) were tested at a frequency of 2Hz on load frames using apparatus specified by ISO 14801 and ALT. Multiple step-stress load profiles with various aggressiveness were used to improve testing efficiency. Fatigue lifetime statistics of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined using SEM with fractographic technique to determine the failure mode. FEA predicted lifetime was within the 95% confidence interval of lifetime estimated by experimental results, which suggested that FEA prediction was accurate for this implant system. The highest probability of failure was located at the root of the implant body screw thread adjacent to the simulated bone level, which also agreed with the failure origin in physical specimens. Fatigue lifetime predictions based on finite element modeling could yield similar results in lieu of physical testing, allowing the use of virtual testing in the early stages of future research projects on implant fatigue. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
Computer-Aided Reliability Estimation
NASA Technical Reports Server (NTRS)
Bavuso, S. J.; Stiffler, J. J.; Bryant, L. A.; Petersen, P. L.
1986-01-01
CARE III (Computer-Aided Reliability Estimation, Third Generation) helps estimate reliability of complex, redundant, fault-tolerant systems. Program specifically designed for evaluation of fault-tolerant avionics systems. However, CARE III general enough for use in evaluation of other systems as well.
Software Carpentry and the Hydrological Sciences
NASA Astrophysics Data System (ADS)
Ahmadia, A. J.; Kees, C. E.; Farthing, M. W.
2013-12-01
Scientists are spending an increasing amount of time building and using hydrology software. However, most scientists are never taught how to do this efficiently. As a result, many are unaware of tools and practices that would allow them to write more reliable and maintainable code with less effort. As hydrology models increase in capability and enter use by a growing number of scientists and their communities, it is important that the scientific software development practices scale up to meet the challenges posed by increasing software complexity, lengthening software lifecycles, a growing number of stakeholders and contributers, and a broadened developer base that extends from application domains to high performance computing centers. Many of these challenges in complexity, lifecycles, and developer base have been successfully met by the open source community, and there are many lessons to be learned from their experiences and practices. Additionally, there is much wisdom to be found in the results of research studies conducted on software engineering itself. Software Carpentry aims to bridge the gap between the current state of software development and these known best practices for scientific software development, with a focus on hands-on exercises and practical advice based on the following principles: 1. Write programs for people, not computers. 2. Automate repetitive tasks 3. Use the computer to record history 4. Make incremental changes 5. Use version control 6. Don't repeat yourself (or others) 7. Plan for mistakes 8. Optimize software only after it works 9. Document design and purpose, not mechanics 10. Collaborate We discuss how these best practices, arising from solid foundations in research and experience, have been shown to help improve scientist's productivity and the reliability of their software.
TEST (Toxicity Estimation Software Tool) Ver 4.1
The Toxicity Estimation Software Tool (T.E.S.T.) has been developed to allow users to easily estimate toxicity and physical properties using a variety of QSAR methodologies. T.E.S.T allows a user to estimate toxicity without requiring any external programs. Users can input a chem...
75 FR 81157 - Version One Regional Reliability Standard for Transmission Operations
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-27
... processing software should be filed in native applications or print-to-PDF format and not in a scanned format..., Inc. v. FERC, 564 F.3d 1342 (D.C. Cir. 2009). \\3\\ NERC designates the version number of a Reliability...
Software Design Improvements. Part 1; Software Benefits and Limitations
NASA Technical Reports Server (NTRS)
Lalli, Vincent R.; Packard, Michael H.; Ziemianski, Tom
1997-01-01
Computer hardware and associated software have been used for many years to process accounting information, to analyze test data and to perform engineering analysis. Now computers and software also control everything from automobiles to washing machines and the number and type of applications are growing at an exponential rate. The size of individual program has shown similar growth. Furthermore, software and hardware are used to monitor and/or control potentially dangerous products and safety-critical systems. These uses include everything from airplanes and braking systems to medical devices and nuclear plants. The question is: how can this hardware and software be made more reliable? Also, how can software quality be improved? What methodology needs to be provided on large and small software products to improve the design and how can software be verified?
Quantitative software models for the estimation of cost, size, and defects
NASA Technical Reports Server (NTRS)
Hihn, J.; Bright, L.; Decker, B.; Lum, K.; Mikulski, C.; Powell, J.
2002-01-01
The presentation will provide a brief overview of the SQI measurement program as well as describe each of these models and how they are currently being used in supporting JPL project, task and software managers to estimate and plan future software systems and subsystems.
Luczak, Susan E; Rosen, I Gary
2014-08-01
Transdermal alcohol sensor (TAS) devices have the potential to allow researchers and clinicians to unobtrusively collect naturalistic drinking data for weeks at a time, but the transdermal alcohol concentration (TAC) data these devices produce do not consistently correspond with breath alcohol concentration (BrAC) data. We present and test the BrAC Estimator software, a program designed to produce individualized estimates of BrAC from TAC data by fitting mathematical models to a specific person wearing a specific TAS device. Two TAS devices were worn simultaneously by 1 participant for 18 days. The trial began with a laboratory alcohol session to calibrate the model and was followed by a field trial with 10 drinking episodes. Model parameter estimates and fit indices were compared across drinking episodes to examine the calibration phase of the software. Software-generated estimates of peak BrAC, time of peak BrAC, and area under the BrAC curve were compared with breath analyzer data to examine the estimation phase of the software. In this single-subject design with breath analyzer peak BrAC scores ranging from 0.013 to 0.057, the software created consistent models for the 2 TAS devices, despite differences in raw TAC data, and was able to compensate for the attenuation of peak BrAC and latency of the time of peak BrAC that are typically observed in TAC data. This software program represents an important initial step for making it possible for non mathematician researchers and clinicians to obtain estimates of BrAC from TAC data in naturalistic drinking environments. Future research with more participants and greater variation in alcohol consumption levels and patterns, as well as examination of gain scheduling calibration procedures and nonlinear models of diffusion, will help to determine how precise these software models can become. Copyright © 2014 by the Research Society on Alcoholism.
Progress in using real-time GPS for seismic monitoring of the Cascadia megathrust
NASA Astrophysics Data System (ADS)
Szeliga, W. M.; Melbourne, T. I.; Santillan, V. M.; Scrivner, C.; Webb, F.
2014-12-01
We report on progress in our development of a comprehensive real-time GPS-based seismic monitoring system for the Cascadia subduction zone. This system is based on 1 Hz point position estimates computed in the ITRF08 reference frame. Convergence from phase and range observables to point position estimates is accelerated using a Kalman filter based, on-line stream editor. Positions are estimated using a short-arc approach and algorithms from JPL's GIPSY-OASIS software with satellite clock and orbit products from the International GNSS Service (IGS). The resulting positions show typical RMS scatter of 2.5 cm in the horizontal and 5 cm in the vertical with latencies below 2 seconds. To facilitate the use of these point position streams for applications such as seismic monitoring, we broadcast real-time positions and covariances using custom-built streaming software. This software is capable of buffering 24-hour streams for hundreds of stations and providing them through a REST-ful web interface. To demonstrate the power of this approach, we have developed a Java-based front-end that provides a real-time visual display of time-series, vector displacement, and contoured peak ground displacement. We have also implemented continuous estimation of finite fault slip along the Cascadia megathrust using an NIF approach. The resulting continuous slip distributions are combined with pre-computed tsunami Green's functions to generate real-time tsunami run-up estimates for the entire Cascadia coastal margin. This Java-based front-end is available for download through the PANGA website. We currently analyze 80 PBO and PANGA stations along the Cascadia margin and are gearing up to process all 400+ real-time stations operating in the Pacific Northwest, many of which are currently telemetered in real-time to CWU. These will serve as milestones towards our over-arching goal of extending our processing to include all of the available real-time streams from the Pacific rim. In addition, we are developing methodologies to combine our real-time solutions with those from Scripps Institute of Oceanography's PPP-AR real-time solutions as well as real-time solutions from the USGS. These combined products should improve the robustness and reliability of real-time point-position streams in the near future.
Securing Ground Data System Applications for Space Operations
NASA Technical Reports Server (NTRS)
Pajevski, Michael J.; Tso, Kam S.; Johnson, Bryan
2014-01-01
The increasing prevalence and sophistication of cyber attacks has prompted the Multimission Ground Systems and Services (MGSS) Program Office at Jet Propulsion Laboratory (JPL) to initiate the Common Access Manager (CAM) effort to protect software applications used in Ground Data Systems (GDSs) at JPL and other NASA Centers. The CAM software provides centralized services and software components used by GDS subsystems to meet access control requirements and ensure data integrity, confidentiality, and availability. In this paper we describe the CAM software; examples of its integration with spacecraft commanding software applications and an information management service; and measurements of its performance and reliability.
A Note on Structural Equation Modeling Estimates of Reliability
ERIC Educational Resources Information Center
Yang, Yanyun; Green, Samuel B.
2010-01-01
Reliability can be estimated using structural equation modeling (SEM). Two potential problems with this approach are that estimates may be unstable with small sample sizes and biased with misspecified models. A Monte Carlo study was conducted to investigate the quality of SEM estimates of reliability by themselves and relative to coefficient…
Estimating Measures of Pass-Fail Reliability from Parallel Half-Tests.
ERIC Educational Resources Information Center
Woodruff, David J.; Sawyer, Richard L.
Two methods for estimating measures of pass-fail reliability are derived, by which both theta and kappa may be estimated from a single test administration. The methods require only a single test administration and are computationally simple. Both are based on the Spearman-Brown formula for estimating stepped-up reliability. The non-distributional…
Large Sample Confidence Intervals for Item Response Theory Reliability Coefficients
ERIC Educational Resources Information Center
Andersson, Björn; Xin, Tao
2018-01-01
In applications of item response theory (IRT), an estimate of the reliability of the ability estimates or sum scores is often reported. However, analytical expressions for the standard errors of the estimators of the reliability coefficients are not available in the literature and therefore the variability associated with the estimated reliability…
Testing of Hand-Held Mine Detection Systems
2015-01-08
ITOP 04-2-5208 for guidance on software testing . Testing software is necessary to ensure that safety is designed into the software algorithm, and that...sensor verification areas or target lanes. F.2. TESTING OBJECTIVES. a. Testing objectives will impact on the test design . Some examples of...overall safety, performance, and reliability of the system. It describes activities necessary to ensure safety is designed into the system under test
Reliability Correction for Functional Connectivity: Theory and Implementation
Mueller, Sophia; Wang, Danhong; Fox, Michael D.; Pan, Ruiqi; Lu, Jie; Li, Kuncheng; Sun, Wei; Buckner, Randy L.; Liu, Hesheng
2016-01-01
Network properties can be estimated using functional connectivity MRI (fcMRI). However, regional variation of the fMRI signal causes systematic biases in network estimates including correlation attenuation in regions of low measurement reliability. Here we computed the spatial distribution of fcMRI reliability using longitudinal fcMRI datasets and demonstrated how pre-estimated reliability maps can correct for correlation attenuation. As a test case of reliability-based attenuation correction we estimated properties of the default network, where reliability was significantly lower than average in the medial temporal lobe and higher in the posterior medial cortex, heterogeneity that impacts estimation of the network. Accounting for this bias using attenuation correction revealed that the medial temporal lobe’s contribution to the default network is typically underestimated. To render this approach useful to a greater number of datasets, we demonstrate that test-retest reliability maps derived from repeated runs within a single scanning session can be used as a surrogate for multi-session reliability mapping. Using data segments with different scan lengths between 1 and 30 min, we found that test-retest reliability of connectivity estimates increases with scan length while the spatial distribution of reliability is relatively stable even at short scan lengths. Finally, analyses of tertiary data revealed that reliability distribution is influenced by age, neuropsychiatric status and scanner type, suggesting that reliability correction may be especially important when studying between-group differences. Collectively, these results illustrate that reliability-based attenuation correction is an easily implemented strategy that mitigates certain features of fMRI signal nonuniformity. PMID:26493163
NASA Astrophysics Data System (ADS)
Baykiev, Eldar; Ebbing, Jörg; Brönner, Marco; Fabian, Karl
2016-11-01
A newly developed software package to calculate the magnetic field in a spherical coordinate system near the Earth's surface and on satellite height is shown to produce reliable modeling results for global and regional applications. The discretization cells of the model are uniformly magnetized spherical prisms, so called tesseroids. The presented algorithm extends an existing code for gravity calculations by applying Poisson's relation to identify the magnetic potential with the sum over pseudogravity fields of tesseroids. By testing different lithosphere discretization grids it is possible to determine the optimal size of tesseroids for field calculations on satellite altitude within realistic measurement error bounds. Also the influence of the Earth's ellipticity upon the modeling result is estimated and global examples are studied. The new software calculates induced and remanent magnetic fields for models at global and regional scale. For regional models far-field effects are evaluated and discussed. This provides bounds for the minimal size of a regional model that is necessary to predict meaningful satellite total field anomalies over the corresponding area.
2008-12-01
between our current project and the historical projects. Therefore to refine the historical volatility estimate of the previously completed software... historical volatility estimates obtained in the form of beliefs and plausibility based on subjective probabilities that take into consideration unique
Estimation of toxicity using a Java based software tool
A software tool has been developed that will allow a user to estimate the toxicity for a variety of endpoints (such as acute aquatic toxicity). The software tool is coded in Java and can be accessed using a web browser (or alternatively downloaded and ran as a stand alone applic...
Reliability program requirements for aeronautical and space system contractors
NASA Technical Reports Server (NTRS)
1987-01-01
General reliability program requirements for NASA contracts involving the design, development, fabrication, test, and/or use of aeronautical and space systems including critical ground support equipment are prescribed. The reliability program requirements require (1) thorough planning and effective management of the reliability effort; (2) definition of the major reliability tasks and their place as an integral part of the design and development process; (3) planning and evaluating the reliability of the system and its elements (including effects of software interfaces) through a program of analysis, review, and test; and (4) timely status indication by formal documentation and other reporting to facilitate control of the reliability program.
ImageJ: A Free, Easy, and Reliable Method to Measure Leg Ulcers Using Digital Pictures.
Aragón-Sánchez, Javier; Quintana-Marrero, Yurena; Aragón-Hernández, Cristina; Hernández-Herero, María José
2017-12-01
Wound measurement to document the healing course of chronic leg ulcers has an important role in the management of these patients. Digital cameras in smartphones are readily available and easy to use, and taking pictures of wounds is becoming a routine in specialized departments. Analyzing digital pictures with appropriate software provides clinicians a quick, clean, and easy-to-use tool for measuring wound area. A set of 25 digital pictures of plain foot and leg ulcers was the basis of this study. Photographs were taken placing a ruler next to the wound in parallel with the healthy skin with the iPhone 6S (Apple Inc, Cupertino, CA), which has a camera of 12 megapixels using the flash. The digital photographs were visualized with ImageJ 1.45s freeware (National Institutes of Health, Rockville, MD; http://imagej.net/ImageJ ). Wound area measurement was carried out by 4 raters: head of the department, wound care nurse, physician, and medical student. We assessed intra- and interrater reliability using the interclass correlation coefficient. To determine intraobserver reliability, 2 of the raters repeated the measurement of the set 1 week after the first reading. The interrater model displayed an interclass correlation coefficient of 0.99 with 95% confidence interval of 0.999 to 1.000, showing excellent reliability. The intrarater model of both examiners showed excellent reliability. In conclusion, analyzing digital images of leg ulcers with ImageJ estimates wound area with excellent reliability. This method provides a free, rapid, and accurate way to measure wounds and could routinely be used to document wound healing in daily clinical practice.
Kortüm, K; Reznicek, L; Leicht, S; Ulbig, M; Wolf, A
2013-07-01
The importance and complexity of clinical trials is continuously increasing, especially in innovative specialties like ophthalmology. Therefore an efficient clinical trial site organisational structure is essential. In modern internet times, this can be accomplished by web-based applications. In total, 3 software applications (Vibe on Prem, Sharepoint and open source software) were evaluated in a clinical trial site in ophthalmology. Assessment criteria were set; they were: reliability, easiness of administration, usability, scheduling, task list, knowledge management, operating costs and worldwide availability. Vibe on Prem customised by the local university met the assessment criteria best. Other applications were not as strong. By introducing a web-based application for administrating and organising an ophthalmological trial site, studies can be conducted in a more efficient and reliable manner. Georg Thieme Verlag KG Stuttgart · New York.
Electronic Health Record for Intensive Care based on Usual Windows Based Software.
Reper, Arnaud; Reper, Pascal
2015-08-01
In Intensive Care Units, the amount of data to be processed for patients care, the turn over of the patients, the necessity for reliability and for review processes indicate the use of Patient Data Management Systems (PDMS) and electronic health records (EHR). To respond to the needs of an Intensive Care Unit and not to be locked with proprietary software, we developed an EHR based on usual software and components. The software was designed as a client-server architecture running on the Windows operating system and powered by the access data base system. The client software was developed using Visual Basic interface library. The application offers to the users the following functions: medical notes captures, observations and treatments, nursing charts with administration of medications, scoring systems for classification, and possibilities to encode medical activities for billing processes. Since his deployment in September 2004, the EHR was used to care more than five thousands patients with the expected software reliability and facilitated data management and review processes. Communications with other medical software were not developed from the start, and are realized by the use of basic functionalities communication engine. Further upgrade of the system will include multi-platform support, use of typed language with static analysis, and configurable interface. The developed system based on usual software components was able to respond to the medical needs of the local ICU environment. The use of Windows for development allowed us to customize the software to the preexisting organization and contributed to the acceptability of the whole system.
Challenges in Managing Trustworthy Large-scale Digital Science
NASA Astrophysics Data System (ADS)
Evans, B. J. K.
2017-12-01
The increased use of large-scale international digital science has opened a number of challenges for managing, handling, using and preserving scientific information. The large volumes of information are driven by three main categories - model outputs including coupled models and ensembles, data products that have been processing to a level of usability, and increasingly heuristically driven data analysis. These data products are increasingly the ones that are usable by the broad communities, and far in excess of the raw instruments data outputs. The data, software and workflows are then shared and replicated to allow broad use at an international scale, which places further demands of infrastructure to support how the information is managed reliably across distributed resources. Users necessarily rely on these underlying "black boxes" so that they are productive to produce new scientific outcomes. The software for these systems depend on computational infrastructure, software interconnected systems, and information capture systems. This ranges from the fundamentals of the reliability of the compute hardware, system software stacks and libraries, and the model software. Due to these complexities and capacity of the infrastructure, there is an increased emphasis of transparency of the approach and robustness of the methods over the full reproducibility. Furthermore, with large volume data management, it is increasingly difficult to store the historical versions of all model and derived data. Instead, the emphasis is on the ability to access the updated products and the reliability by which both previous outcomes are still relevant and can be updated for the new information. We will discuss these challenges and some of the approaches underway that are being used to address these issues.
Study on Collision of Ship Side Structure by Simplified Plastic Analysis Method
NASA Astrophysics Data System (ADS)
Sun, C. J.; Zhou, J. H.; Wu, W.
2017-10-01
During its lifetime, a ship may encounter collision or grounding and sustain permanent damage after these types of accidents. Crashworthiness has been based on two kinds of main methods: simplified plastic analysis and numerical simulation. A simplified plastic analysis method is presented in this paper. Numerical methods using the non-linear finite-element software LS-DYNA are conducted to validate the method. The results show that, as for the accuracy of calculation results, the simplified plasticity analysis are in good agreement with the finite element simulation, which reveals that the simplified plasticity analysis method can quickly and accurately estimate the crashworthiness of the side structure during the collision process and can be used as a reliable risk assessment method.
Addendum to the User Manual for NASGRO Elastic-Plastic Fracture Mechanics Software Module
NASA Technical Reports Server (NTRS)
Gregg, M. Wayne (Technical Monitor); Chell, Graham; Gardner, Brian
2003-01-01
The elastic-plastic fracture mechanics modules in NASGRO have been enhanced by the addition of of the following: new J-integral solutions based on the reference stress method and finite element solutions; the extension of the critical crack and critical load modules for cracks with two degrees of freedom that tear and failure by ductile instability; the addition of a proof test analysis module that includes safe life analysis, calculates proof loads, and determines the flaw screening 1 capability for a given proof load; the addition of a tear-fatigue module for ductile materials that simultaneously tear and extend by fatigue; and a multiple cycle proof test module for estimating service reliability following a proof test.
Reliability of four models for clinical gait analysis.
Kainz, Hans; Graham, David; Edwards, Julie; Walsh, Henry P J; Maine, Sheanna; Boyd, Roslyn N; Lloyd, David G; Modenese, Luca; Carty, Christopher P
2017-05-01
Three-dimensional gait analysis (3DGA) has become a common clinical tool for treatment planning in children with cerebral palsy (CP). Many clinical gait laboratories use the conventional gait analysis model (e.g. Plug-in-Gait model), which uses Direct Kinematics (DK) for joint kinematic calculations, whereas, musculoskeletal models, mainly used for research, use Inverse Kinematics (IK). Musculoskeletal IK models have the advantage of enabling additional analyses which might improve the clinical decision-making in children with CP. Before any new model can be used in a clinical setting, its reliability has to be evaluated and compared to a commonly used clinical gait model (e.g. Plug-in-Gait model) which was the purpose of this study. Two testers performed 3DGA in eleven CP and seven typically developing participants on two occasions. Intra- and inter-tester standard deviations (SD) and standard error of measurement (SEM) were used to compare the reliability of two DK models (Plug-in-Gait and a six degrees-of-freedom model solved using Vicon software) and two IK models (two modifications of 'gait2392' solved using OpenSim). All models showed good reliability (mean SEM of 3.0° over all analysed models and joint angles). Variations in joint kinetics were less in typically developed than in CP participants. The modified 'gait2392' model which included all the joint rotations commonly reported in clinical 3DGA, showed reasonable reliable joint kinematic and kinetic estimates, and allows additional musculoskeletal analysis on surgically adjustable parameters, e.g. muscle-tendon lengths, and, therefore, is a suitable model for clinical gait analysis. Copyright © 2017. Published by Elsevier B.V.
Lisi, Simonetta; Chirichella, Michele; Arisi, Ivan; Goracci, Martina; Cremisi, Federico; Cattaneo, Antonino
2017-01-01
Antibody libraries are important resources to derive antibodies to be used for a wide range of applications, from structural and functional studies to intracellular protein interference studies to developing new diagnostics and therapeutics. Whatever the goal, the key parameter for an antibody library is its complexity (also known as diversity), i.e. the number of distinct elements in the collection, which directly reflects the probability of finding in the library an antibody against a given antigen, of sufficiently high affinity. Quantitative evaluation of antibody library complexity and quality has been for a long time inadequately addressed, due to the high similarity and length of the sequences of the library. Complexity was usually inferred by the transformation efficiency and tested either by fingerprinting and/or sequencing of a few hundred random library elements. Inferring complexity from such a small sampling is, however, very rudimental and gives limited information about the real diversity, because complexity does not scale linearly with sample size. Next-generation sequencing (NGS) has opened new ways to tackle the antibody library complexity quality assessment. However, much remains to be done to fully exploit the potential of NGS for the quantitative analysis of antibody repertoires and to overcome current limitations. To obtain a more reliable antibody library complexity estimate here we show a new, PCR-free, NGS approach to sequence antibody libraries on Illumina platform, coupled to a new bioinformatic analysis and software (Diversity Estimator of Antibody Library, DEAL) that allows to reliably estimate the complexity, taking in consideration the sequencing error. PMID:28505201
Fantini, Marco; Pandolfini, Luca; Lisi, Simonetta; Chirichella, Michele; Arisi, Ivan; Terrigno, Marco; Goracci, Martina; Cremisi, Federico; Cattaneo, Antonino
2017-01-01
Antibody libraries are important resources to derive antibodies to be used for a wide range of applications, from structural and functional studies to intracellular protein interference studies to developing new diagnostics and therapeutics. Whatever the goal, the key parameter for an antibody library is its complexity (also known as diversity), i.e. the number of distinct elements in the collection, which directly reflects the probability of finding in the library an antibody against a given antigen, of sufficiently high affinity. Quantitative evaluation of antibody library complexity and quality has been for a long time inadequately addressed, due to the high similarity and length of the sequences of the library. Complexity was usually inferred by the transformation efficiency and tested either by fingerprinting and/or sequencing of a few hundred random library elements. Inferring complexity from such a small sampling is, however, very rudimental and gives limited information about the real diversity, because complexity does not scale linearly with sample size. Next-generation sequencing (NGS) has opened new ways to tackle the antibody library complexity quality assessment. However, much remains to be done to fully exploit the potential of NGS for the quantitative analysis of antibody repertoires and to overcome current limitations. To obtain a more reliable antibody library complexity estimate here we show a new, PCR-free, NGS approach to sequence antibody libraries on Illumina platform, coupled to a new bioinformatic analysis and software (Diversity Estimator of Antibody Library, DEAL) that allows to reliably estimate the complexity, taking in consideration the sequencing error.
Mantovani, Giulia; Pifferi, Massimo; Vozzi, Giovanni
2010-06-01
Patients with primary ciliary dyskinesia (PCD) have structural and/or functional alterations of cilia that imply deficits in mucociliary clearance and different respiratory pathologies. A useful indicator for the difficult diagnosis is the ciliary beat frequency (CBF) that is significantly lower in pathological cases than in physiological ones. The CBF computation is not rapid, therefore, the aim of this study is to propose an automated method to evaluate it directly from videos of ciliated cells. The cells are taken from inferior nasal turbinates and videos of ciliary movements are registered and eventually processed by the developed software. The software consists in the extraction of features from videos (written with C++ language) and the computation of the frequency (written with Matlab language). This system was tested both on the samples of nasal cavity and software models, and the results were really promising because in a few seconds, it can compute a reliable frequency if compared with that measured with visual methods. It is to be noticed that the reliability of the computation increases with the quality of acquisition system and especially with the sampling frequency. It is concluded that the developed software could be a useful mean for PCD diagnosis.
Automating Structural Analysis of Spacecraft Vehicles
NASA Technical Reports Server (NTRS)
Hrinda, Glenn A.
2004-01-01
A major effort within NASA's vehicle analysis discipline has been to automate structural analysis and sizing optimization during conceptual design studies of advanced spacecraft. Traditional spacecraft structural sizing has involved detailed finite element analysis (FEA) requiring large degree-of-freedom (DOF) finite element models (FEM). Creation and analysis of these models can be time consuming and limit model size during conceptual designs. The goal is to find an optimal design that meets the mission requirements but produces the lightest structure. A structural sizing tool called HyperSizer has been successfully used in the conceptual design phase of a reusable launch vehicle and planetary exploration spacecraft. The program couples with FEA to enable system level performance assessments and weight predictions including design optimization of material selections and sizing of spacecraft members. The software's analysis capabilities are based on established aerospace structural methods for strength, stability and stiffness that produce adequately sized members and reliable structural weight estimates. The software also helps to identify potential structural deficiencies early in the conceptual design so changes can be made without wasted time. HyperSizer's automated analysis and sizing optimization increases productivity and brings standardization to a systems study. These benefits will be illustrated in examining two different types of conceptual spacecraft designed using the software. A hypersonic air breathing, single stage to orbit (SSTO), reusable launch vehicle (RLV) will be highlighted as well as an aeroshell for a planetary exploration vehicle used for aerocapture at Mars. By showing the two different types of vehicles, the software's flexibility will be demonstrated with an emphasis on reducing aeroshell structural weight. Member sizes, concepts and material selections will be discussed as well as analysis methods used in optimizing the structure. Analysis based on the HyperSizer structural sizing software will be discussed. Design trades required to optimize structural weight will be presented.
Contal, Olivier; Vignaux, Laurence; Combescure, Christophe; Pepin, Jean-Louis; Jolliet, Philippe; Janssens, Jean-Paul
2012-02-01
Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Tools Ensure Reliability of Critical Software
NASA Technical Reports Server (NTRS)
2012-01-01
In November 2006, after attempting to make a routine maneuver, NASA's Mars Global Surveyor (MGS) reported unexpected errors. The onboard software switched to backup resources, and a 2-day lapse in communication took place between the spacecraft and Earth. When a signal was finally received, it indicated that MGS had entered safe mode, a state of restricted activity in which the computer awaits instructions from Earth. After more than 9 years of successful operation gathering data and snapping pictures of Mars to characterize the planet's land and weather communication between MGS and Earth suddenly stopped. Months later, a report from NASA's internal review board found the spacecraft's battery failed due to an unfortunate sequence of events. Updates to the spacecraft's software, which had taken place months earlier, were written to the wrong memory address in the spacecraft's computer. In short, the mission ended because of a software defect. Over the last decade, spacecraft have become increasingly reliant on software to carry out mission operations. In fact, the next mission to Mars, the Mars Science Laboratory, will rely on more software than all earlier missions to Mars combined. According to Gerard Holzmann, manager at the Laboratory for Reliable Software (LaRS) at NASA's Jet Propulsion Laboratory (JPL), even the fault protection systems on a spacecraft are mostly software-based. For reasons like these, well-functioning software is critical for NASA. In the same year as the failure of MGS, Holzmann presented a new approach to critical software development to help reduce risk and provide consistency. He proposed The Power of 10: Rules for Developing Safety-Critical Code, which is a small set of rules that can easily be remembered, clearly relate to risk, and allow compliance to be verified. The reaction at JPL was positive, and developers in the private sector embraced Holzmann's ideas.
Data collection and evaluation for experimental computer science research
NASA Technical Reports Server (NTRS)
Zelkowitz, Marvin V.
1983-01-01
The Software Engineering Laboratory was monitoring software development at NASA Goddard Space Flight Center since 1976. The data collection activities of the Laboratory and some of the difficulties of obtaining reliable data are described. In addition, the application of this data collection process to a current prototyping experiment is reviewed.
Ka-Band Link Study and Analysis for a Mars Hybrid RF/Optical Software Defined Radio
NASA Technical Reports Server (NTRS)
Zeleznikar, Daniel J.; Nappier, Jennifer M.; Downey, Joseph A.
2014-01-01
The integrated radio and optical communications (iROC) project at the NASA Glenn Research Center (GRC) is investigating the feasibility of a hybrid RF and optical communication subsystem for future deep space missions. The hybrid communications subsystem enables the advancement of optical communications while simultaneously mitigating the risk of infusion by combining an experimental optical transmitter and telescope with a reliable Ka-band RF transmitter and antenna. The iROC communications subsystem seeks to maximize the total data return over the course of a potential 2-year mission in Mars orbit beginning in 2021. Although optical communication by itself offers potential for greater data return over RF, the reliable Ka-band link is also being designed for high data return capability in this hybrid system. A daily analysis of the RF link budget over the 2-year span is performed to optimize and provide detailed estimates of the RF data return. In particular, the bandwidth dependence of these data return estimates is analyzed for candidate waveforms. In this effort, a data return modeling tool was created to analyze candidate RF modulation and coding schemes with respect to their spectral efficiency, amplifier output power back-off, required digital to analog conversion (DAC) sampling rates, and support by ground receivers. A set of RF waveforms is recommended for use on the iROC platform.
Krishnamoorthy, Vignesh P; Perumal, Rajamani; Daniel, Alfred J; Poonnoose, Pradeep M
2015-12-01
Templating of the acetabular cup size in Total Hip Replacement (THR) is normally done using conventional radiographs. As these are being replaced by digital radiographs, it has become essential to create a technique of templating using digital films. We describe a technique that involves templating the digital films using the universally available acetate templates for THR without the use of special software. Preoperative digital radiographs of the pelvis were taken with a 30 mm diameter spherical metal ball strapped over the greater trochanter. Using standard acetate templates provided by the implant company on magnified digital radiographs, the size of the metal ball (X mm) and acetabular cup (Y mm) were determined. The size of the acetabular cup to be implanted was estimated using the formula 30*Y/X. The estimated size was compared with the actual size of the cup used at surgery. Using this technique, it was possible to accurately predict the acetabular cup size in 28/40 (70%) of the hips. When the accuracy to within one size was considered, templating was correct in 90% (36/40). When assessed by two independent observers, there was good intra-observer and inter-observer reliability with intra-class correlation coefficient values greater than 0.8. It was possible to accurately and reliably predict the size of the acetabular cup, using acetate templates on digital films, without any digital templates.
Clayson, Peter E; Miller, Gregory A
2017-01-01
Failing to consider psychometric issues related to reliability and validity, differential deficits, and statistical power potentially undermines the conclusions of a study. In research using event-related brain potentials (ERPs), numerous contextual factors (population sampled, task, data recording, analysis pipeline, etc.) can impact the reliability of ERP scores. The present review considers the contextual factors that influence ERP score reliability and the downstream effects that reliability has on statistical analyses. Given the context-dependent nature of ERPs, it is recommended that ERP score reliability be formally assessed on a study-by-study basis. Recommended guidelines for ERP studies include 1) reporting the threshold of acceptable reliability and reliability estimates for observed scores, 2) specifying the approach used to estimate reliability, and 3) justifying how trial-count minima were chosen. A reliability threshold for internal consistency of at least 0.70 is recommended, and a threshold of 0.80 is preferred. The review also advocates the use of generalizability theory for estimating score dependability (the generalizability theory analog to reliability) as an improvement on classical test theory reliability estimates, suggesting that the latter is less well suited to ERP research. To facilitate the calculation and reporting of dependability estimates, an open-source Matlab program, the ERP Reliability Analysis Toolbox, is presented. Copyright © 2016 Elsevier B.V. All rights reserved.
A particle swarm model for estimating reliability and scheduling system maintenance
NASA Astrophysics Data System (ADS)
Puzis, Rami; Shirtz, Dov; Elovici, Yuval
2016-05-01
Modifying data and information system components may introduce new errors and deteriorate the reliability of the system. Reliability can be efficiently regained with reliability centred maintenance, which requires reliability estimation for maintenance scheduling. A variant of the particle swarm model is used to estimate reliability of systems implemented according to the model view controller paradigm. Simulations based on data collected from an online system of a large financial institute are used to compare three component-level maintenance policies. Results show that appropriately scheduled component-level maintenance greatly reduces the cost of upholding an acceptable level of reliability by reducing the need in system-wide maintenance.
Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement.
Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi
2015-03-01
Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Photographs were found to have high reliability coefficient (P > 0.05). The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement.
NASA Technical Reports Server (NTRS)
Lalli, Vincent R. (Editor); Malec, Henry A. (Editor); Dillard, Richard B.; Wong, Kam L.; Barber, Frank J.; Barina, Frank J.
1992-01-01
Discussed here is failure physics, the study of how products, hardware, software, and systems fail and what can be done about it. The intent is to impart useful information, to extend the limits of production capability, and to assist in achieving low cost reliable products. A review of reliability for the years 1940 to 2000 is given. Next, a review of mathematics is given as well as a description of what elements contribute to product failures. Basic reliability theory and the disciplines that allow us to control and eliminate failures are elucidated.
Automated verification of flight software. User's manual
NASA Technical Reports Server (NTRS)
Saib, S. H.
1982-01-01
(Automated Verification of Flight Software), a collection of tools for analyzing source programs written in FORTRAN and AED is documented. The quality and the reliability of flight software are improved by: (1) indented listings of source programs, (2) static analysis to detect inconsistencies in the use of variables and parameters, (3) automated documentation, (4) instrumentation of source code, (5) retesting guidance, (6) analysis of assertions, (7) symbolic execution, (8) generation of verification conditions, and (9) simplification of verification conditions. Use of AVFS in the verification of flight software is described.
An Exploratory Study of Software Cost Estimating at the Electronic Systems Division.
1976-07-01
action’. to improve the software cost Sestimating proces., While thin research was limited to the M.nD onvironment, the same types of problema may exist...Methods in Social Science. Now York: Random House, 1969. 57. Smith, Ronald L. Structured Programming Series (Vol. XI) - Estimating Software Project
2003-03-01
27 2.8.5 Marginal Analysis Method...Figure 11 Improved Configuration of Figure 10; Increases Basic System Reliability..... 26 Figure 12 Example of marginal analysis ...View of Main Book of Software ............................................................... 51 Figure 20 The View of Data Worksheet
ERIC Educational Resources Information Center
Lee, Guemin; Park, In-Yong
2012-01-01
Previous assessments of the reliability of test scores for testlet-composed tests have indicated that item-based estimation methods overestimate reliability. This study was designed to address issues related to the extent to which item-based estimation methods overestimate the reliability of test scores composed of testlets and to compare several…
Camp, Christopher L; Heidenreich, Mark J; Dahm, Diane L; Bond, Jeffrey R; Collins, Mark S; Krych, Aaron J
2016-03-01
Tibial tubercle-trochlear groove (TT-TG) distance is a variable that helps guide surgical decision-making in patients with patellar instability. The purpose of this study was to compare the accuracy and reliability of an MRI TT-TG measuring technique using a simple external alignment method to a previously validated gold standard technique that requires advanced software read by radiologists. TT-TG was calculated by MRI on 59 knees with a clinical diagnosis of patellar instability in a blinded and randomized fashion by two musculoskeletal radiologists using advanced software and by two orthopaedists using the study technique which utilizes measurements taken on a simple electronic imaging platform. Interrater reliability between the two radiologists and the two orthopaedists and intermethods reliability between the two techniques were calculated using interclass correlation coefficients (ICC) and concordance correlation coefficients (CCC). ICC and CCC values greater than 0.75 were considered to represent excellent agreement. The mean TT-TG distance was 14.7 mm (Standard Deviation (SD) 4.87 mm) and 15.4 mm (SD 5.41) as measured by the radiologists and orthopaedists, respectively. Excellent interobserver agreement was noted between the radiologists (ICC 0.941; CCC 0.941), the orthopaedists (ICC 0.978; CCC 0.976), and the two techniques (ICC 0.941; CCC 0.933). The simple TT-TG distance measurement technique analysed in this study resulted in excellent agreement and reliability as compared to the gold standard technique. This method can predictably be performed by orthopaedic surgeons without advanced radiologic software. II.
Cost benefits of advanced software: A review of methodology used at Kennedy Space Center
NASA Technical Reports Server (NTRS)
Joglekar, Prafulla N.
1993-01-01
To assist rational investments in advanced software, a formal, explicit, and multi-perspective cost-benefit analysis methodology is proposed. The methodology can be implemented through a six-stage process which is described and explained. The current practice of cost-benefit analysis at KSC is reviewed in the light of this methodology. The review finds that there is a vicious circle operating. Unsound methods lead to unreliable cost-benefit estimates. Unreliable estimates convince management that cost-benefit studies should not be taken seriously. Then, given external demands for cost-benefit estimates, management encourages software enginees to somehow come up with the numbers for their projects. Lacking the expertise needed to do a proper study, courageous software engineers with vested interests use ad hoc and unsound methods to generate some estimates. In turn, these estimates are unreliable, and the cycle continues. The proposed methodology should help KSC to break out of this cycle.
Evidence of absence (v2.0) software user guide
Dalthorp, Daniel; Huso, Manuela; Dail, David
2017-07-06
Evidence of Absence software (EoA) is a user-friendly software application for estimating bird and bat fatalities at wind farms and for designing search protocols. The software is particularly useful in addressing whether the number of fatalities is below a given threshold and what search parameters are needed to give assurance that thresholds were not exceeded. The software also includes tools (1) for estimating carcass persistence distributions and searcher efficiency parameters ( and ) from field trials, (2) for projecting future mortality based on past monitoring data, and (3) for exploring the potential consequences of various choices in the design of long-term incidental take permits for protected species. The software was designed specifically for cases where tolerance for mortality is low and carcass counts are small or even 0, but the tools also may be used for mortality estimates when carcass counts are large.
Analysis of Air Traffic Track Data with the AutoBayes Synthesis System
NASA Technical Reports Server (NTRS)
Schumann, Johann Martin Philip; Cate, Karen; Lee, Alan G.
2010-01-01
The Next Generation Air Traffic System (NGATS) is aiming to provide substantial computer support for the air traffic controllers. Algorithms for the accurate prediction of aircraft movements are of central importance for such software systems but trajectory prediction has to work reliably in the presence of unknown parameters and uncertainties. We are using the AutoBayes program synthesis system to generate customized data analysis algorithms that process large sets of aircraft radar track data in order to estimate parameters and uncertainties. In this paper, we present, how the tasks of finding structure in track data, estimation of important parameters in climb trajectories, and the detection of continuous descent approaches can be accomplished with compact task-specific AutoBayes specifications. We present an overview of the AutoBayes architecture and describe, how its schema-based approach generates customized analysis algorithms, documented C/C++ code, and detailed mathematical derivations. Results of experiments with actual air traffic control data are discussed.
NASA Technical Reports Server (NTRS)
Gilyard, G. B.; Edwards, J. W.
1983-01-01
Flight flutter-test results of the first aeroelastic research wing (ARW-1) of NASA's drones for aerodynamic and structural testing program are presented. The flight-test operation and the implementation of the active flutter-suppression system are described as well as the software techniques used to obtain real-time damping estimates and the actual flutter testing procedure. Real-time analysis of fast-frequency aileron excitation sweeps provided reliable damping estimates. The open-loop flutter boundary was well defined at two altitudes; a maximum Mach number of 0.91 was obtained. Both open-loop and closed-loop data were of exceptionally high quality. Although the flutter-suppression system provided augmented damping at speeds below the flutter boundary, an error in the implementation of the system resulted in the system being less stable than predicted. The vehicle encountered system-on flutter shortly after crossing the open-loop flutter boundary on the third flight and was lost. The aircraft was rebuilt. Changes made in real-time test techniques are included.
La Delfa, Nicholas J; Potvin, Jim R
2017-03-01
This paper describes the development of a novel method (termed the 'Arm Force Field' or 'AFF') to predict manual arm strength (MAS) for a wide range of body orientations, hand locations and any force direction. This method used an artificial neural network (ANN) to predict the effects of hand location and force direction on MAS, and included a method to estimate the contribution of the arm's weight to the predicted strength. The AFF method predicted the MAS values very well (r 2 = 0.97, RMSD = 5.2 N, n = 456) and maintained good generalizability with external test data (r 2 = 0.842, RMSD = 13.1 N, n = 80). The AFF can be readily integrated within any DHM ergonomics software, and appears to be a more robust, reliable and valid method of estimating the strength capabilities of the arm, when compared to current approaches. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yilmaz, Şeyda, E-mail: seydayilmaz@ktu.edu.tr; Bayrak, Erdem, E-mail: erdmbyrk@gmail.com; Bayrak, Yusuf, E-mail: bayrak@ktu.edu.tr
In this study we examined and compared the three different probabilistic distribution methods for determining the best suitable model in probabilistic assessment of earthquake hazards. We analyzed a reliable homogeneous earthquake catalogue between a time period 1900-2015 for magnitude M ≥ 6.0 and estimated the probabilistic seismic hazard in the North Anatolian Fault zone (39°-41° N 30°-40° E) using three distribution methods namely Weibull distribution, Frechet distribution and three-parameter Weibull distribution. The distribution parameters suitability was evaluated Kolmogorov-Smirnov (K-S) goodness-of-fit test. We also compared the estimated cumulative probability and the conditional probabilities of occurrence of earthquakes for different elapsed timemore » using these three distribution methods. We used Easyfit and Matlab software to calculate these distribution parameters and plotted the conditional probability curves. We concluded that the Weibull distribution method was the most suitable than other distribution methods in this region.« less
A Fault Tolerant System for an Integrated Avionics Sensor Configuration
NASA Technical Reports Server (NTRS)
Caglayan, A. K.; Lancraft, R. E.
1984-01-01
An aircraft sensor fault tolerant system methodology for the Transport Systems Research Vehicle in a Microwave Landing System (MLS) environment is described. The fault tolerant system provides reliable estimates in the presence of possible failures both in ground-based navigation aids, and in on-board flight control and inertial sensors. Sensor failures are identified by utilizing the analytic relationships between the various sensors arising from the aircraft point mass equations of motion. The estimation and failure detection performance of the software implementation (called FINDS) of the developed system was analyzed on a nonlinear digital simulation of the research aircraft. Simulation results showing the detection performance of FINDS, using a dual redundant sensor compliment, are presented for bias, hardover, null, ramp, increased noise and scale factor failures. In general, the results show that FINDS can distinguish between normal operating sensor errors and failures while providing an excellent detection speed for bias failures in the MLS, indicated airspeed, attitude and radar altimeter sensors.
1981-04-30
However, SREM was not designed to harmonize these kinds of problems. Rather, it is a tool to investigate the logic of the processing specified in the... design . Supoorting programs were also conducted to perform basic research into such areas as software reliability, static and dynamic validation techniques...development. 0 Maintain requirements development independent of the target machine and the eventual software design . 0. Allow for easy response to
An Open Avionics and Software Architecture to Support Future NASA Exploration Missions
NASA Technical Reports Server (NTRS)
Schlesinger, Adam
2017-01-01
The presentation describes an avionics and software architecture that has been developed through NASAs Advanced Exploration Systems (AES) division. The architecture is open-source, highly reliable with fault tolerance, and utilizes standard capabilities and interfaces, which are scalable and customizable to support future exploration missions. Specific focus areas of discussion will include command and data handling, software, human interfaces, communication and wireless systems, and systems engineering and integration.
Component Verification and Certification in NASA Missions
NASA Technical Reports Server (NTRS)
Giannakopoulou, Dimitra; Penix, John; Norvig, Peter (Technical Monitor)
2001-01-01
Software development for NASA missions is a particularly challenging task. Missions are extremely ambitious scientifically, have very strict time frames, and must be accomplished with a maximum degree of reliability. Verification technologies must therefore be pushed far beyond their current capabilities. Moreover, reuse and adaptation of software architectures and components must be incorporated in software development within and across missions. This paper discusses NASA applications that we are currently investigating from these perspectives.
Sign: large-scale gene network estimation environment for high performance computing.
Tamada, Yoshinori; Shimamura, Teppei; Yamaguchi, Rui; Imoto, Seiya; Nagasaki, Masao; Miyano, Satoru
2011-01-01
Our research group is currently developing software for estimating large-scale gene networks from gene expression data. The software, called SiGN, is specifically designed for the Japanese flagship supercomputer "K computer" which is planned to achieve 10 petaflops in 2012, and other high performance computing environments including Human Genome Center (HGC) supercomputer system. SiGN is a collection of gene network estimation software with three different sub-programs: SiGN-BN, SiGN-SSM and SiGN-L1. In these three programs, five different models are available: static and dynamic nonparametric Bayesian networks, state space models, graphical Gaussian models, and vector autoregressive models. All these models require a huge amount of computational resources for estimating large-scale gene networks and therefore are designed to be able to exploit the speed of 10 petaflops. The software will be available freely for "K computer" and HGC supercomputer system users. The estimated networks can be viewed and analyzed by Cell Illustrator Online and SBiP (Systems Biology integrative Pipeline). The software project web site is available at http://sign.hgc.jp/ .
Lyerla, R; Gouws, E; García-Calleja, J M; Zaniewski, E
2006-06-01
This paper describes improvements and updates to an established approach to making epidemiological estimates of HIV prevalence in countries with low level and concentrated epidemics. The structure of the software used to make estimates is briefly described, with particular attention to changes and improvements. The approach focuses on identifying populations which, through their behaviour, are at high risk of infection with HIV or who are exposed through the risk behaviour of their sexual partners. Estimates of size and HIV prevalence of these populations allow the total number of HIV infected people in a country or region to be estimated. Major changes in the software focus on the move away from short term projections and towards developing an epidemiological curve that more accurately represents the change in prevalence of HIV over time. The software continues to provide an output file for use in the Spectrum software so as to estimate the demographic impact of HIV infection at country level.
ERIC Educational Resources Information Center
Black, Ryan A.; Yang, Yanyun; Beitra, Danette; McCaffrey, Stacey
2015-01-01
Estimation of composite reliability within a hierarchical modeling framework has recently become of particular interest given the growing recognition that the underlying assumptions of coefficient alpha are often untenable. Unfortunately, coefficient alpha remains the prominent estimate of reliability when estimating total scores from a scale with…
Fields, David A; Allison, David B
2012-08-01
The objective of this study was to determine the accuracy, precision, bias, and reliability of percent fat (%fat) determined by air-displacement plethysmography (ADP) with the pediatric option against the four-compartment model in 31 children (4.1 ± 1.2 years, 103.3 ± 10.2 cm, 17.5 ± 3.4 kg). %Fat was determined by (BOD POD Body Composition System; COSMED USA, Concord, CA) with the pediatric option. Total body water (TBW) was determined by isotope dilution ((2)H(2)O; 0.2 g/kg) while bone mineral was determined by dual-energy X-ray absorptiometry (DXA) (Lunar iDXA v13.31; GE, Fairfield, CT and analyzed using enCore 2010 software). The four-compartment model by Lohman was used as the criterion measure of %fat. The regression for %fat by ADP vs. %fat by the four-compartment model did not deviate from the line of identity where: y = 0.849(x) + 4.291. ADP explained 75.2% of the variance in %fat by the four-compartment model while the standard error of the estimate (SEE) was 2.09 %fat. The Bland-Altman analysis showed %fat by ADP did not exhibit any bias across the range of fatness (r = 0.04; P = 0.81). The reliability of ADP was assessed by the coefficient of variation (CV), within-subject SD, and Cronbach's α. The CV was 3.5%, within-subject SD was 0.9%, and Cronbach's α was 0.95. In conclusion, ADP with the pediatric option is accurate, precise, reliable, and without bias in estimating %fat in children 2-6 years old.
VDA, a Method of Choosing a Better Algorithm with Fewer Validations
Kluger, Yuval
2011-01-01
The multitude of bioinformatics algorithms designed for performing a particular computational task presents end-users with the problem of selecting the most appropriate computational tool for analyzing their biological data. The choice of the best available method is often based on expensive experimental validation of the results. We propose an approach to design validation sets for method comparison and performance assessment that are effective in terms of cost and discrimination power. Validation Discriminant Analysis (VDA) is a method for designing a minimal validation dataset to allow reliable comparisons between the performances of different algorithms. Implementation of our VDA approach achieves this reduction by selecting predictions that maximize the minimum Hamming distance between algorithmic predictions in the validation set. We show that VDA can be used to correctly rank algorithms according to their performances. These results are further supported by simulations and by realistic algorithmic comparisons in silico. VDA is a novel, cost-efficient method for minimizing the number of validation experiments necessary for reliable performance estimation and fair comparison between algorithms. Our VDA software is available at http://sourceforge.net/projects/klugerlab/files/VDA/ PMID:22046256
A Comparison of Three Multivariate Models for Estimating Test Battery Reliability.
ERIC Educational Resources Information Center
Wood, Terry M.; Safrit, Margaret J.
1987-01-01
A comparison of three multivariate models (canonical reliability model, maximum generalizability model, canonical correlation model) for estimating test battery reliability indicated that the maximum generalizability model showed the least degree of bias, smallest errors in estimation, and the greatest relative efficiency across all experimental…
SCoT: a Python toolbox for EEG source connectivity.
Billinger, Martin; Brunner, Clemens; Müller-Putz, Gernot R
2014-01-01
Analysis of brain connectivity has become an important research tool in neuroscience. Connectivity can be estimated between cortical sources reconstructed from the electroencephalogram (EEG). Such analysis often relies on trial averaging to obtain reliable results. However, some applications such as brain-computer interfaces (BCIs) require single-trial estimation methods. In this paper, we present SCoT-a source connectivity toolbox for Python. This toolbox implements routines for blind source decomposition and connectivity estimation with the MVARICA approach. Additionally, a novel extension called CSPVARICA is available for labeled data. SCoT estimates connectivity from various spectral measures relying on vector autoregressive (VAR) models. Optionally, these VAR models can be regularized to facilitate ill posed applications such as single-trial fitting. We demonstrate basic usage of SCoT on motor imagery (MI) data. Furthermore, we show simulation results of utilizing SCoT for feature extraction in a BCI application. These results indicate that CSPVARICA and correct regularization can significantly improve MI classification. While SCoT was mainly designed for application in BCIs, it contains useful tools for other areas of neuroscience. SCoT is a software package that (1) brings combined source decomposition and connectivtiy estimation to the open Python platform, and (2) offers tools for single-trial connectivity estimation. The source code is released under the MIT license and is available online at github.com/SCoT-dev/SCoT.
SCoT: a Python toolbox for EEG source connectivity
Billinger, Martin; Brunner, Clemens; Müller-Putz, Gernot R.
2014-01-01
Analysis of brain connectivity has become an important research tool in neuroscience. Connectivity can be estimated between cortical sources reconstructed from the electroencephalogram (EEG). Such analysis often relies on trial averaging to obtain reliable results. However, some applications such as brain-computer interfaces (BCIs) require single-trial estimation methods. In this paper, we present SCoT—a source connectivity toolbox for Python. This toolbox implements routines for blind source decomposition and connectivity estimation with the MVARICA approach. Additionally, a novel extension called CSPVARICA is available for labeled data. SCoT estimates connectivity from various spectral measures relying on vector autoregressive (VAR) models. Optionally, these VAR models can be regularized to facilitate ill posed applications such as single-trial fitting. We demonstrate basic usage of SCoT on motor imagery (MI) data. Furthermore, we show simulation results of utilizing SCoT for feature extraction in a BCI application. These results indicate that CSPVARICA and correct regularization can significantly improve MI classification. While SCoT was mainly designed for application in BCIs, it contains useful tools for other areas of neuroscience. SCoT is a software package that (1) brings combined source decomposition and connectivtiy estimation to the open Python platform, and (2) offers tools for single-trial connectivity estimation. The source code is released under the MIT license and is available online at github.com/SCoT-dev/SCoT. PMID:24653694
EPEPT: A web service for enhanced P-value estimation in permutation tests
2011-01-01
Background In computational biology, permutation tests have become a widely used tool to assess the statistical significance of an event under investigation. However, the common way of computing the P-value, which expresses the statistical significance, requires a very large number of permutations when small (and thus interesting) P-values are to be accurately estimated. This is computationally expensive and often infeasible. Recently, we proposed an alternative estimator, which requires far fewer permutations compared to the standard empirical approach while still reliably estimating small P-values [1]. Results The proposed P-value estimator has been enriched with additional functionalities and is made available to the general community through a public website and web service, called EPEPT. This means that the EPEPT routines can be accessed not only via a website, but also programmatically using any programming language that can interact with the web. Examples of web service clients in multiple programming languages can be downloaded. Additionally, EPEPT accepts data of various common experiment types used in computational biology. For these experiment types EPEPT first computes the permutation values and then performs the P-value estimation. Finally, the source code of EPEPT can be downloaded. Conclusions Different types of users, such as biologists, bioinformaticians and software engineers, can use the method in an appropriate and simple way. Availability http://informatics.systemsbiology.net/EPEPT/ PMID:22024252
Software development for safety-critical medical applications
NASA Technical Reports Server (NTRS)
Knight, John C.
1992-01-01
There are many computer-based medical applications in which safety and not reliability is the overriding concern. Reduced, altered, or no functionality of such systems is acceptable as long as no harm is done. A precise, formal definition of what software safety means is essential, however, before any attempt can be made to achieve it. Without this definition, it is not possible to determine whether a specific software entity is safe. A set of definitions pertaining to software safety will be presented and a case study involving an experimental medical device will be described. Some new techniques aimed at improving software safety will also be discussed.
The implementation and use of Ada on distributed systems with high reliability requirements
NASA Technical Reports Server (NTRS)
Knight, J. C.
1984-01-01
The use and implementation of Ada in distributed environments in which reliability is the primary concern is investigated. Emphasis is placed on the possibility that a distributed system may be programmed entirely in ADA so that the individual tasks of the system are unconcerned with which processors they are executing on, and that failures may occur in the software or underlying hardware. The primary activities are: (1) Continued development and testing of our fault-tolerant Ada testbed; (2) consideration of desirable language changes to allow Ada to provide useful semantics for failure; (3) analysis of the inadequacies of existing software fault tolerance strategies.
A six-legged rover for planetary exploration
NASA Technical Reports Server (NTRS)
Simmons, Reid; Krotkov, Eric; Bares, John
1991-01-01
To survive the rigors and isolation of planetary exploration, an autonomous rover must be competent, reliable, and efficient. This paper presents the Ambler, a six-legged robot featuring orthogonal legs and a novel circulating gait, which has been designed for traversal of rugged, unknown environments. An autonomous software system that integrates perception, planning, and real-time control has been developed to walk the Ambler through obstacle strewn terrain. The paper describes the information and control flow of the walking system, and how the design of the mechanism and software combine to achieve competent walking, reliable behavior in the face of unexpected failures, and efficient utilization of time and power.
Sowunmi, Olaperi Yeside; Misra, Sanjay; Fernandez-Sanz, Luis; Crawford, Broderick; Soto, Ricardo
2016-01-01
The importance of quality assurance in the software development process cannot be overemphasized because its adoption results in high reliability and easy maintenance of the software system and other software products. Software quality assurance includes different activities such as quality control, quality management, quality standards, quality planning, process standardization and improvement amongst others. The aim of this work is to further investigate the software quality assurance practices of practitioners in Nigeria. While our previous work covered areas on quality planning, adherence to standardized processes and the inherent challenges, this work has been extended to include quality control, software process improvement and international quality standard organization membership. It also makes comparison based on a similar study carried out in Turkey. The goal is to generate more robust findings that can properly support decision making by the software community. The qualitative research approach, specifically, the use of questionnaire research instruments was applied to acquire data from software practitioners. In addition to the previous results, it was observed that quality assurance practices are quite neglected and this can be the cause of low patronage. Moreover, software practitioners are neither aware of international standards organizations or the required process improvement techniques; as such their claimed standards are not aligned to those of accredited bodies, and are only limited to their local experience and knowledge, which makes it questionable. The comparison with Turkey also yielded similar findings, making the results typical of developing countries. The research instrument used was tested for internal consistency using the Cronbach's alpha, and it was proved reliable. For the software industry in developing countries to grow strong and be a viable source of external revenue, software assurance practices have to be taken seriously because its effect is evident in the final product. Moreover, quality frameworks and tools which require minimum time and cost are highly needed in these countries.
2012-02-01
parameter estimation method, but rather to carefully describe how to use the ERDC software implementation of MLSL that accommodates the PEST model...model independent LM method based parameter estimation software PEST (Doherty, 2004, 2007a, 2007b), which quantifies model to measure- ment misfit...et al. (2011) focused on one drawback associated with LM-based model independent parameter estimation as implemented in PEST ; viz., that it requires
A Decision Support System for Planning, Control and Auditing of DoD Software Cost Estimation.
1986-03-01
is frequently used in U. S. Air Force software cost estimates. Barry Boehm’s Constructive Cost Estimation Model (COCOMO) was recently selected for use...are considered basic to the proper development of software. Pressman , [Ref. 11], addresses these basic elements in a manner which attempts to integrate...H., Jr., and Carlson, Eric D., Building E fective Decision SUDDOrt Systems, Prentice-Hal, EnglewoodNJ, 1982 11. Pressman , Roger S., o A Practioner’s A
Methods for cost estimation in software project management
NASA Astrophysics Data System (ADS)
Briciu, C. V.; Filip, I.; Indries, I. I.
2016-02-01
The speed in which the processes used in software development field have changed makes it very difficult the task of forecasting the overall costs for a software project. By many researchers, this task has been considered unachievable, but there is a group of scientist for which this task can be solved using the already known mathematical methods (e.g. multiple linear regressions) and the new techniques as genetic programming and neural networks. The paper presents a solution for building a model for the cost estimation models in the software project management using genetic algorithms starting from the PROMISE datasets related COCOMO 81 model. In the first part of the paper, a summary of the major achievements in the research area of finding a model for estimating the overall project costs is presented together with the description of the existing software development process models. In the last part, a basic proposal of a mathematical model of a genetic programming is proposed including here the description of the chosen fitness function and chromosome representation. The perspective of model described it linked with the current reality of the software development considering as basis the software product life cycle and the current challenges and innovations in the software development area. Based on the author's experiences and the analysis of the existing models and product lifecycle it was concluded that estimation models should be adapted with the new technologies and emerging systems and they depend largely by the chosen software development method.
Software Architecture of Sensor Data Distribution In Planetary Exploration
NASA Technical Reports Server (NTRS)
Lee, Charles; Alena, Richard; Stone, Thom; Ossenfort, John; Walker, Ed; Notario, Hugo
2006-01-01
Data from mobile and stationary sensors will be vital in planetary surface exploration. The distribution and collection of sensor data in an ad-hoc wireless network presents a challenge. Irregular terrain, mobile nodes, new associations with access points and repeaters with stronger signals as the network reconfigures to adapt to new conditions, signal fade and hardware failures can cause: a) Data errors; b) Out of sequence packets; c) Duplicate packets; and d) Drop out periods (when node is not connected). To mitigate the effects of these impairments, a robust and reliable software architecture must be implemented. This architecture must also be tolerant of communications outages. This paper describes such a robust and reliable software infrastructure that meets the challenges of a distributed ad hoc network in a difficult environment and presents the results of actual field experiments testing the principles and actual code developed.
CrossTalk: The Journal of Defense Software Engineering. Volume 20, Number 6, June 2007
2007-06-01
California. He has co-authored the book Software Cost Estimation With COCOMO II with Barry Boehm and others. Clark helped define the COCOMO II model...Software Engineering at the University of Southern California. She worked with Barry Boehm and Chris Abts to develop and calibrate a cost-estimation...2003/02/ schorsch.html>. 2. See “Software Engineering, A Practitioners Approach” by Roger Pressman for a good description of coupling, cohesion
Open source electronic health record and patient data management system for intensive care.
Massaut, Jacques; Reper, Pascal
2008-01-01
In Intensive Care Units, the amount of data to be processed for patients care, the turn over of the patients, the necessity for reliability and for review processes indicate the use of Patient Data Management Systems (PDMS) and electronic health records (EHR). To respond to the needs of an Intensive Care Unit and not to be locked with proprietary software, we developed a PDMS and EHR based on open source software and components. The software was designed as a client-server architecture running on the Linux operating system and powered by the PostgreSQL data base system. The client software was developed in C using GTK interface library. The application offers to the users the following functions: medical notes captures, observations and treatments, nursing charts with administration of medications, scoring systems for classification, and possibilities to encode medical activities for billing processes. Since his deployment in February 2004, the PDMS was used to care more than three thousands patients with the expected software reliability and facilitated data management and review processes. Communications with other medical software were not developed from the start, and are realized by the use of the Mirth HL7 communication engine. Further upgrade of the system will include multi-platform support, use of typed language with static analysis, and configurable interface. The developed system based on open source software components was able to respond to the medical needs of the local ICU environment. The use of OSS for development allowed us to customize the software to the preexisting organization and contributed to the acceptability of the whole system.
Improving Software Engineering on NASA Projects
NASA Technical Reports Server (NTRS)
Crumbley, Tim; Kelly, John C.
2010-01-01
Software Engineering Initiative: Reduces risk of software failure -Increases mission safety. More predictable software cost estimates and delivery schedules. Smarter buyer of contracted out software. More defects found and removed earlier. Reduces duplication of efforts between projects. Increases ability to meet the challenges of evolving software technology.
NASA Astrophysics Data System (ADS)
Nair, S. P.; Righetti, R.
2015-05-01
Recent elastography techniques focus on imaging information on properties of materials which can be modeled as viscoelastic or poroelastic. These techniques often require the fitting of temporal strain data, acquired from either a creep or stress-relaxation experiment to a mathematical model using least square error (LSE) parameter estimation. It is known that the strain versus time relationships for tissues undergoing creep compression have a non-linear relationship. In non-linear cases, devising a measure of estimate reliability can be challenging. In this article, we have developed and tested a method to provide non linear LSE parameter estimate reliability: which we called Resimulation of Noise (RoN). RoN provides a measure of reliability by estimating the spread of parameter estimates from a single experiment realization. We have tested RoN specifically for the case of axial strain time constant parameter estimation in poroelastic media. Our tests show that the RoN estimated precision has a linear relationship to the actual precision of the LSE estimator. We have also compared results from the RoN derived measure of reliability against a commonly used reliability measure: the correlation coefficient (CorrCoeff). Our results show that CorrCoeff is a poor measure of estimate reliability for non-linear LSE parameter estimation. While the RoN is specifically tested only for axial strain time constant imaging, a general algorithm is provided for use in all LSE parameter estimation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Hang Bae
A reliability testing was performed for the software of Shutdown(SDS) Computers for Wolsong Nuclear Power Plants Units 2, 3 and 4. profiles to the SDS Computers and compared the outputs with the predicted results generated by the oracle. Test softwares were written to execute the test automatically. Random test profiles were generated using analysis code. 11 refs., 1 fig.
beta-Aminoalcohols as Potential Reactivators of Aged Sarin-/Soman-Inhibited Acetylcholinesterase
2017-02-08
This approach includes high - quality quantum mechanical/molecular mechanical calcula- tions, providing reliable reactivation steps and energetics...I. V. Khavrutskii Department of Defense Biotechnology High Performance Computing Software Applications Institute Telemedicine and Advanced...b] Dr. A. Wallqvist Department of Defense Biotechnology High Performance Computing Software Applications Institute Telemedicine and Advanced
CrossTalk: The Journal of Defense Software Engineering. Volume 19, Number 11
2006-11-01
8>. 7. Wallace, Delores R. Practical Soft- ware Reliability Modeling. Proc. of the 26th Annual NASA Goddard Software Engineering Workshop, Nov. 2001...STAR WARS TO STAR TREK To Request Back Issues on Topics Not Listed Above, Please Contact <stsc. customerservice@hill.af.mil>. About the Authors Kym
ERIC Educational Resources Information Center
Cibbarelli, Pamela
1996-01-01
Examines library automation product introductions and conversions to new operating systems. Compares user satisfaction ratings of the following library software packages: DOS/Windows, UNIX, Macintosh, and DEC VAX/VMS. Software is rated according to documentation, service/support, training, product reliability, product capabilities, ease of use,…
A new software-based architecture for quantum computer
NASA Astrophysics Data System (ADS)
Wu, Nan; Song, FangMin; Li, Xiangdong
2010-04-01
In this paper, we study a reliable architecture of a quantum computer and a new instruction set and machine language for the architecture, which can improve the performance and reduce the cost of the quantum computing. We also try to address some key issues in detail in the software-driven universal quantum computers.
Seamon, Bryant A.; Teixeira, Carla; Ismail, Catheeja
2016-01-01
Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of interest (ROI) within an ultrasound image. The primary objective of this study is to determine the intrarater and interrater reliability of Photoshop and ImageJ for the estimate of muscle tissue echogenicity in older adults via grayscale histogram analysis. The secondary objective is to compare the mean grayscale values obtained using both the RMT and FHT methods across both image analysis platforms. Methods. This cross-sectional observational study features 18 community-dwelling men (age = 61.5 ± 2.32 years). Longitudinal views of the rectus femoris were captured using B-mode ultrasound. The ROI for each scan was selected by 2 examiners using the RMT and FHT methods from each software program. Their reliability is assessed using intraclass correlation coefficients (ICCs) and the standard error of the measurement (SEM). Measurement agreement for these values is depicted using Bland-Altman plots. A paired t-test is used to determine mean differences in echogenicity expressed as grayscale values using the RMT and FHT methods to select the post-image acquisition ROI. The degree of association among ROI selection methods and image analysis platforms is analyzed using the coefficient of determination (R2). Results. The raters demonstrated excellent intrarater and interrater reliability using the RMT and FHT methods across both platforms (lower bound 95% CI ICC = .97–.99, p < .001). Mean differences between the echogenicity estimates obtained with the RMT and FHT methods was .87 grayscale levels (95% CI [.54–1.21], p < .0001) using data obtained with both programs. The SEM for Photoshop was .97 and 1.05 grayscale levels when using the RMT and FHT ROI selection methods, respectively. Comparatively, the SEM values were .72 and .81 grayscale levels, respectively, when using the RMT and FHT ROI selection methods in ImageJ. Uniform coefficients of determination (R2 = .96–.99, p < .001) indicate strong positive associations among the grayscale histogram analysis measurement conditions independent of the ROI selection methods and imaging platform. Conclusion. Our method for evaluating muscle echogenicity demonstrated a high degree of intrarater and interrater reliability using both the RMT and FHT methods across 2 common image analysis platforms. The minimal measurement error exhibited by the examiners demonstrates that the ROI selection methods used with Photoshop and ImageJ are suitable for the post-acquisition image analysis of tissue echogenicity in older adults. PMID:26925339
Automation Hooks Architecture Trade Study for Flexible Test Orchestration
NASA Technical Reports Server (NTRS)
Lansdowne, Chatwin A.; Maclean, John R.; Graffagnino, Frank J.; McCartney, Patrick A.
2010-01-01
We describe the conclusions of a technology and communities survey supported by concurrent and follow-on proof-of-concept prototyping to evaluate feasibility of defining a durable, versatile, reliable, visible software interface to support strategic modularization of test software development. The objective is that test sets and support software with diverse origins, ages, and abilities can be reliably integrated into test configurations that assemble and tear down and reassemble with scalable complexity in order to conduct both parametric tests and monitored trial runs. The resulting approach is based on integration of three recognized technologies that are currently gaining acceptance within the test industry and when combined provide a simple, open and scalable test orchestration architecture that addresses the objectives of the Automation Hooks task. The technologies are automated discovery using multicast DNS Zero Configuration Networking (zeroconf), commanding and data retrieval using resource-oriented Restful Web Services, and XML data transfer formats based on Automatic Test Markup Language (ATML). This open-source standards-based approach provides direct integration with existing commercial off-the-shelf (COTS) analysis software tools.
A high-speed linear algebra library with automatic parallelism
NASA Technical Reports Server (NTRS)
Boucher, Michael L.
1994-01-01
Parallel or distributed processing is key to getting highest performance workstations. However, designing and implementing efficient parallel algorithms is difficult and error-prone. It is even more difficult to write code that is both portable to and efficient on many different computers. Finally, it is harder still to satisfy the above requirements and include the reliability and ease of use required of commercial software intended for use in a production environment. As a result, the application of parallel processing technology to commercial software has been extremely small even though there are numerous computationally demanding programs that would significantly benefit from application of parallel processing. This paper describes DSSLIB, which is a library of subroutines that perform many of the time-consuming computations in engineering and scientific software. DSSLIB combines the high efficiency and speed of parallel computation with a serial programming model that eliminates many undesirable side-effects of typical parallel code. The result is a simple way to incorporate the power of parallel processing into commercial software without compromising maintainability, reliability, or ease of use. This gives significant advantages over less powerful non-parallel entries in the market.
Engineering and Software Engineering
NASA Astrophysics Data System (ADS)
Jackson, Michael
The phrase ‘software engineering' has many meanings. One central meaning is the reliable development of dependable computer-based systems, especially those for critical applications. This is not a solved problem. Failures in software development have played a large part in many fatalities and in huge economic losses. While some of these failures may be attributable to programming errors in the narrowest sense—a program's failure to satisfy a given formal specification—there is good reason to think that most of them have other roots. These roots are located in the problem of software engineering rather than in the problem of program correctness. The famous 1968 conference was motivated by the belief that software development should be based on “the types of theoretical foundations and practical disciplines that are traditional in the established branches of engineering.” Yet after forty years of currency the phrase ‘software engineering' still denotes no more than a vague and largely unfulfilled aspiration. Two major causes of this disappointment are immediately clear. First, too many areas of software development are inadequately specialised, and consequently have not developed the repertoires of normal designs that are the indispensable basis of reliable engineering success. Second, the relationship between structural design and formal analytical techniques for software has rarely been one of fruitful synergy: too often it has defined a boundary between competing dogmas, at which mutual distrust and incomprehension deprive both sides of advantages that should be within their grasp. This paper discusses these causes and their effects. Whether the common practice of software development will eventually satisfy the broad aspiration of 1968 is hard to predict; but an understanding of past failure is surely a prerequisite of future success.
Calculating system reliability with SRFYDO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morzinski, Jerome; Anderson - Cook, Christine M; Klamann, Richard M
2010-01-01
SRFYDO is a process for estimating reliability of complex systems. Using information from all applicable sources, including full-system (flight) data, component test data, and expert (engineering) judgment, SRFYDO produces reliability estimates and predictions. It is appropriate for series systems with possibly several versions of the system which share some common components. It models reliability as a function of age and up to 2 other lifecycle (usage) covariates. Initial output from its Exploratory Data Analysis mode consists of plots and numerical summaries so that the user can check data entry and model assumptions, and help determine a final form for themore » system model. The System Reliability mode runs a complete reliability calculation using Bayesian methodology. This mode produces results that estimate reliability at the component, sub-system, and system level. The results include estimates of uncertainty, and can predict reliability at some not-too-distant time in the future. This paper presents an overview of the underlying statistical model for the analysis, discusses model assumptions, and demonstrates usage of SRFYDO.« less
Integrated Software Health Management for Aircraft GN and C
NASA Technical Reports Server (NTRS)
Schumann, Johann; Mengshoel, Ole
2011-01-01
Modern aircraft rely heavily on dependable operation of many safety-critical software components. Despite careful design, verification and validation (V&V), on-board software can fail with disastrous consequences if it encounters problematic software/hardware interaction or must operate in an unexpected environment. We are using a Bayesian approach to monitor the software and its behavior during operation and provide up-to-date information about the health of the software and its components. The powerful reasoning mechanism provided by our model-based Bayesian approach makes reliable diagnosis of the root causes possible and minimizes the number of false alarms. Compilation of the Bayesian model into compact arithmetic circuits makes SWHM feasible even on platforms with limited CPU power. We show initial results of SWHM on a small simulator of an embedded aircraft software system, where software and sensor faults can be injected.
Nurturing reliable and robust open-source scientific software
NASA Astrophysics Data System (ADS)
Uieda, L.; Wessel, P.
2017-12-01
Scientific results are increasingly the product of software. The reproducibility and validity of published results cannot be ensured without access to the source code of the software used to produce them. Therefore, the code itself is a fundamental part of the methodology and must be published along with the results. With such a reliance on software, it is troubling that most scientists do not receive formal training in software development. Tools such as version control, continuous integration, and automated testing are routinely used in industry to ensure the correctness and robustness of software. However, many scientist do not even know of their existence (although efforts like Software Carpentry are having an impact on this issue; software-carpentry.org). Publishing the source code is only the first step in creating an open-source project. For a project to grow it must provide documentation, participation guidelines, and a welcoming environment for new contributors. Expanding the project community is often more challenging than the technical aspects of software development. Maintainers must invest time to enforce the rules of the project and to onboard new members, which can be difficult to justify in the context of the "publish or perish" mentality. This problem will continue as long as software contributions are not recognized as valid scholarship by hiring and tenure committees. Furthermore, there are still unsolved problems in providing attribution for software contributions. Many journals and metrics of academic productivity do not recognize citations to sources other than traditional publications. Thus, some authors choose to publish an article about the software and use it as a citation marker. One issue with this approach is that updating the reference to include new contributors involves writing and publishing a new article. A better approach would be to cite a permanent archive of individual versions of the source code in services such as Zenodo (zenodo.org). However, citations to these sources are not always recognized when computing citation metrics. In summary, the widespread development of reliable and robust open-source software relies on the creation of formal training programs in software development best practices and the recognition of software as a valid form of scholarship.
Autonomous robot software development using simple software components
NASA Astrophysics Data System (ADS)
Burke, Thomas M.; Chung, Chan-Jin
2004-10-01
Developing software to control a sophisticated lane-following, obstacle-avoiding, autonomous robot can be demanding and beyond the capabilities of novice programmers - but it doesn"t have to be. A creative software design utilizing only basic image processing and a little algebra, has been employed to control the LTU-AISSIG autonomous robot - a contestant in the 2004 Intelligent Ground Vehicle Competition (IGVC). This paper presents a software design equivalent to that used during the IGVC, but with much of the complexity removed. The result is an autonomous robot software design, that is robust, reliable, and can be implemented by programmers with a limited understanding of image processing. This design provides a solid basis for further work in autonomous robot software, as well as an interesting and achievable robotics project for students.
Usability Evaluation of Air Warfare Assessment & Review Toolset in Exercise Black Skies 2012
2013-12-01
is, it allows the user to do what they want to do with it ( Pressman , 2005). This concept is sometimes called fitness for purpose (Nielsen, 1993...Other characteristics of good software defined by Pressman (2005) are: reliability – the proportion of time the software is available for its intended...Diego, CA: Academic Press,. Pressman , R. S. (2005). Software Engineering: A Practitioner’s Approach. New York: McGraw- Hill. Symons, S., France, M
Wu, Weifei; Liang, Jie; Du, Yuanli; Tan, Xiaoyi; Xiang, Xuanping; Wang, Wanhong; Ru, Neng; Le, Jinbo
2014-02-06
Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2-T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson's coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino-pelvic measurement in T2-T5, PT, PI, SS, and LL.
2014-01-01
Background Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Methods Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. Results There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2–T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson’s coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Conclusion Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino-pelvic measurement in T2-T5, PT, PI, SS, and LL. PMID:24502397
FloWave.US: validated, open-source, and flexible software for ultrasound blood flow analysis.
Coolbaugh, Crystal L; Bush, Emily C; Caskey, Charles F; Damon, Bruce M; Towse, Theodore F
2016-10-01
Automated software improves the accuracy and reliability of blood velocity, vessel diameter, blood flow, and shear rate ultrasound measurements, but existing software offers limited flexibility to customize and validate analyses. We developed FloWave.US-open-source software to automate ultrasound blood flow analysis-and demonstrated the validity of its blood velocity (aggregate relative error, 4.32%) and vessel diameter (0.31%) measures with a skeletal muscle ultrasound flow phantom. Compared with a commercial, manual analysis software program, FloWave.US produced equivalent in vivo cardiac cycle time-averaged mean (TAMean) velocities at rest and following a 10-s muscle contraction (mean bias <1 pixel for both conditions). Automated analysis of ultrasound blood flow data was 9.8 times faster than the manual method. Finally, a case study of a lower extremity muscle contraction experiment highlighted the ability of FloWave.US to measure small fluctuations in TAMean velocity, vessel diameter, and mean blood flow at specific time points in the cardiac cycle. In summary, the collective features of our newly designed software-accuracy, reliability, reduced processing time, cost-effectiveness, and flexibility-offer advantages over existing proprietary options. Further, public distribution of FloWave.US allows researchers to easily access and customize code to adapt ultrasound blood flow analysis to a variety of vascular physiology applications. Copyright © 2016 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Yu, Z. P.; Yue, Z. F.; Liu, W.
2018-05-01
With the development of artificial intelligence, more and more reliability experts have noticed the roles of subjective information in the reliability design of complex system. Therefore, based on the certain numbers of experiment data and expert judgments, we have divided the reliability estimation based on distribution hypothesis into cognition process and reliability calculation. Consequently, for an illustration of this modification, we have taken the information fusion based on intuitional fuzzy belief functions as the diagnosis model of cognition process, and finished the reliability estimation for the open function of cabin door affected by the imprecise judgment corresponding to distribution hypothesis.
Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement
Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi
2015-01-01
Objectives: Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Materials and Methods: Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Results: Photographs were found to have high reliability coefficient (P > 0.05). Conclusion: The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement. PMID:26622272
Modification Site Localization in Peptides.
Chalkley, Robert J
2016-01-01
There are a large number of search engines designed to take mass spectrometry fragmentation spectra and match them to peptides from proteins in a database. These peptides could be unmodified, but they could also bear modifications that were added biologically or during sample preparation. As a measure of reliability for the peptide identification, software normally calculates how likely a given quality of match could have been achieved at random, most commonly through the use of target-decoy database searching (Elias and Gygi, Nat Methods 4(3): 207-214, 2007). Matching the correct peptide but with the wrong modification localization is not a random match, so results with this error will normally still be assessed as reliable identifications by the search engine. Hence, an extra step is required to determine site localization reliability, and the software approaches to measure this are the subject of this part of the chapter.
CARES/Life Software for Designing More Reliable Ceramic Parts
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Powers, Lynn M.; Baker, Eric H.
1997-01-01
Products made from advanced ceramics show great promise for revolutionizing aerospace and terrestrial propulsion, and power generation. However, ceramic components are difficult to design because brittle materials in general have widely varying strength values. The CAPES/Life software eases this task by providing a tool to optimize the design and manufacture of brittle material components using probabilistic reliability analysis techniques. Probabilistic component design involves predicting the probability of failure for a thermomechanically loaded component from specimen rupture data. Typically, these experiments are performed using many simple geometry flexural or tensile test specimens. A static, dynamic, or cyclic load is applied to each specimen until fracture. Statistical strength and SCG (fatigue) parameters are then determined from these data. Using these parameters and the results obtained from a finite element analysis, the time-dependent reliability for a complex component geometry and loading is then predicted. Appropriate design changes are made until an acceptable probability of failure has been reached.
A Robust Compositional Architecture for Autonomous Systems
NASA Technical Reports Server (NTRS)
Brat, Guillaume; Deney, Ewen; Farrell, Kimberley; Giannakopoulos, Dimitra; Jonsson, Ari; Frank, Jeremy; Bobby, Mark; Carpenter, Todd; Estlin, Tara
2006-01-01
Space exploration applications can benefit greatly from autonomous systems. Great distances, limited communications and high costs make direct operations impossible while mandating operations reliability and efficiency beyond what traditional commanding can provide. Autonomous systems can improve reliability and enhance spacecraft capability significantly. However, there is reluctance to utilizing autonomous systems. In part this is due to general hesitation about new technologies, but a more tangible concern is that of reliability of predictability of autonomous software. In this paper, we describe ongoing work aimed at increasing robustness and predictability of autonomous software, with the ultimate goal of building trust in such systems. The work combines state-of-the-art technologies and capabilities in autonomous systems with advanced validation and synthesis techniques. The focus of this paper is on the autonomous system architecture that has been defined, and on how it enables the application of validation techniques for resulting autonomous systems.
Software Suite to Support In-Flight Characterization of Remote Sensing Systems
NASA Technical Reports Server (NTRS)
Stanley, Thomas; Holekamp, Kara; Gasser, Gerald; Tabor, Wes; Vaughan, Ronald; Ryan, Robert; Pagnutti, Mary; Blonski, Slawomir; Kenton, Ross
2014-01-01
A characterization software suite was developed to facilitate NASA's in-flight characterization of commercial remote sensing systems. Characterization of aerial and satellite systems requires knowledge of ground characteristics, or ground truth. This information is typically obtained with instruments taking measurements prior to or during a remote sensing system overpass. Acquired ground-truth data, which can consist of hundreds of measurements with different data formats, must be processed before it can be used in the characterization. Accurate in-flight characterization of remote sensing systems relies on multiple field data acquisitions that are efficiently processed, with minimal error. To address the need for timely, reproducible ground-truth data, a characterization software suite was developed to automate the data processing methods. The characterization software suite is engineering code, requiring some prior knowledge and expertise to run. The suite consists of component scripts for each of the three main in-flight characterization types: radiometric, geometric, and spatial. The component scripts for the radiometric characterization operate primarily by reading the raw data acquired by the field instruments, combining it with other applicable information, and then reducing it to a format that is appropriate for input into MODTRAN (MODerate resolution atmospheric TRANsmission), an Air Force Research Laboratory-developed radiative transport code used to predict at-sensor measurements. The geometric scripts operate by comparing identified target locations from the remote sensing image to known target locations, producing circular error statistics defined by the Federal Geographic Data Committee Standards. The spatial scripts analyze a target edge within the image, and produce estimates of Relative Edge Response and the value of the Modulation Transfer Function at the Nyquist frequency. The software suite enables rapid, efficient, automated processing of ground truth data, which has been used to provide reproducible characterizations on a number of commercial remote sensing systems. Overall, this characterization software suite improves the reliability of ground-truth data processing techniques that are required for remote sensing system in-flight characterizations.
GEDAE-LaB: A Free Software to Calculate the Energy System Contributions during Exercise
Bertuzzi, Rômulo; Melegati, Jorge; Bueno, Salomão; Ghiarone, Thaysa; Pasqua, Leonardo A.; Gáspari, Arthur Fernandes; Lima-Silva, Adriano E.; Goldman, Alfredo
2016-01-01
Purpose The aim of the current study is to describe the functionality of free software developed for energy system contributions and energy expenditure calculation during exercise, namely GEDAE-LaB. Methods Eleven participants performed the following tests: 1) a maximal cycling incremental test to measure the ventilatory threshold and maximal oxygen uptake (V˙O2max); 2) a cycling workload constant test at moderate domain (90% ventilatory threshold); 3) a cycling workload constant test at severe domain (110% V˙O2max). Oxygen uptake and plasma lactate were measured during the tests. The contributions of the aerobic (AMET), anaerobic lactic (LAMET), and anaerobic alactic (ALMET) systems were calculated based on the oxygen uptake during exercise, the oxygen energy equivalents provided by lactate accumulation, and the fast component of excess post-exercise oxygen consumption, respectively. In order to assess the intra-investigator variation, four different investigators performed the analyses independently using GEDAE-LaB. A direct comparison with commercial software was also provided. Results All subjects completed 10 min of exercise at moderate domain, while the time to exhaustion at severe domain was 144 ± 65 s. The AMET, LAMET, and ALMET contributions during moderate domain were about 93, 2, and 5%, respectively. The AMET, LAMET, and ALMET contributions during severe domain were about 66, 21, and 13%, respectively. No statistical differences were found between the energy system contributions and energy expenditure obtained by GEDAE-LaB and commercial software for both moderate and severe domains (P > 0.05). The ICC revealed that these estimates were highly reliable among the four investigators for both moderate and severe domains (all ICC ≥ 0.94). Conclusion These findings suggest that GEDAE-LaB is a free software easily comprehended by users minimally familiarized with adopted procedures for calculations of energetic profile using oxygen uptake and lactate accumulation during exercise. By providing availability of the software and its source code we hope to facilitate future related research. PMID:26727499
GEDAE-LaB: A Free Software to Calculate the Energy System Contributions during Exercise.
Bertuzzi, Rômulo; Melegati, Jorge; Bueno, Salomão; Ghiarone, Thaysa; Pasqua, Leonardo A; Gáspari, Arthur Fernandes; Lima-Silva, Adriano E; Goldman, Alfredo
2016-01-01
The aim of the current study is to describe the functionality of free software developed for energy system contributions and energy expenditure calculation during exercise, namely GEDAE-LaB. Eleven participants performed the following tests: 1) a maximal cycling incremental test to measure the ventilatory threshold and maximal oxygen uptake (V̇O2max); 2) a cycling workload constant test at moderate domain (90% ventilatory threshold); 3) a cycling workload constant test at severe domain (110% V̇O2max). Oxygen uptake and plasma lactate were measured during the tests. The contributions of the aerobic (AMET), anaerobic lactic (LAMET), and anaerobic alactic (ALMET) systems were calculated based on the oxygen uptake during exercise, the oxygen energy equivalents provided by lactate accumulation, and the fast component of excess post-exercise oxygen consumption, respectively. In order to assess the intra-investigator variation, four different investigators performed the analyses independently using GEDAE-LaB. A direct comparison with commercial software was also provided. All subjects completed 10 min of exercise at moderate domain, while the time to exhaustion at severe domain was 144 ± 65 s. The AMET, LAMET, and ALMET contributions during moderate domain were about 93, 2, and 5%, respectively. The AMET, LAMET, and ALMET contributions during severe domain were about 66, 21, and 13%, respectively. No statistical differences were found between the energy system contributions and energy expenditure obtained by GEDAE-LaB and commercial software for both moderate and severe domains (P > 0.05). The ICC revealed that these estimates were highly reliable among the four investigators for both moderate and severe domains (all ICC ≥ 0.94). These findings suggest that GEDAE-LaB is a free software easily comprehended by users minimally familiarized with adopted procedures for calculations of energetic profile using oxygen uptake and lactate accumulation during exercise. By providing availability of the software and its source code we hope to facilitate future related research.
Are Validity and Reliability "Relevant" in Qualitative Evaluation Research?
ERIC Educational Resources Information Center
Goodwin, Laura D.; Goodwin, William L.
1984-01-01
The views of prominant qualitative methodologists on the appropriateness of validity and reliability estimation for the measurement strategies employed in qualitative evaluations are summarized. A case is made for the relevance of validity and reliability estimation. Definitions of validity and reliability for qualitative measurement are presented…