Sample records for evaluate assay specificity

  1. Sensitivity and Specificity of Human Immunodeficiency Virus Rapid Serologic Assays and Testing Algorithms in an Antenatal Clinic in Abidjan, Ivory Coast

    PubMed Central

    Koblavi-Dème, Stéphania; Maurice, Chantal; Yavo, Daniel; Sibailly, Toussaint S.; N′guessan, Kabran; Kamelan-Tano, Yvonne; Wiktor, Stefan Z.; Roels, Thierry H.; Chorba, Terence; Nkengasong, John N.

    2001-01-01

    To evaluate serologic testing algorithms for human immunodeficiency virus (HIV) based on a combination of rapid assays among persons with HIV-1 (non-B subtypes) infection, HIV-2 infection, and HIV-1–HIV-2 dual infections in Abidjan, Ivory Coast, a total of 1,216 sera with known HIV serologic status were used to evaluate the sensitivity and specificity of four rapid assays: Determine HIV-1/2, Capillus HIV-1/HIV-2, HIV-SPOT, and Genie II HIV-1/HIV-2. Two serum panels obtained from patients recently infected with HIV-1 subtypes B and non-B were also included. Based on sensitivity and specificity, three of the four rapid assays were evaluated prospectively in parallel (serum samples tested by two simultaneous rapid assays) and serial (serum samples tested by two consecutive rapid assays) testing algorithms. All assays were 100% sensitive, and specificities ranged from 99.4 to 100%. In the prospective evaluation, both the parallel and serial algorithms were 100% sensitive and specific. Our results suggest that rapid assays have high sensitivity and specificity and, when used in parallel or serial testing algorithms, yield results similar to those of enzyme-linked immunosorbent assay-based testing strategies. HIV serodiagnosis based on rapid assays may be a valuable alternative in implementing HIV prevention and surveillance programs in areas where sophisticated laboratories are difficult to establish. PMID:11325995

  2. Evaluation of Swine-Specific PCR Assays Used for Fecal Source Tracking and Analysis of Molecular Diversity of Swine-Specific "Bacteroidales" Populations

    EPA Science Inventory

    In this study we evaluated specificity, distribution, and sensitivity of Bacteroidales – (PF163 and PigBac1) and methanogen-based (P23-2) assays proposed to detect swine fecal pollution in environmental waters. The assays were tested against 220 fecal DNA extracts derived from t...

  3. Evaluation of seven assays detecting serum immunoglobulin classes and subclasses and salivary and faecal secretory IgA against Fasciola excretory/secretory (ES) antigens in diagnosing fascioliasis.

    PubMed

    Noureldin, Mohamed S; el-Ganaini, Goman A; Abou El-Enin, Ahmed M; el-Nemr, Hosam-Eldin I; Hussin, Eman M; Sultan, Doaa M

    2004-08-01

    Seven assays detecting serum IgM, IgG, IgG1, IgG4, IgA and salivary and fecal excretory IgA against Fasciola excretory/secretory (ES) antigens were evaluated in diagnosing fascioliasis, for cross reactivity with Schistosoma mansoni sera and for evaluation of cure of Fasciola infection after treatment. Assays detecting sera IgM, IgG1, IgG4 and IgA against Fasciola ES antigens showed 100% specificity and sensitivity. Assays detecting IgM and IgG showed 98% and 96% sensitivity and 100% and 94.6% specificity respectively. Assays detecting salivary and faecal IgA showed 92% & 96% sensitivity and 100% & 100% specificity respectively. Assays detecting IgM and IgG4 were the best in evaluation of cure and assays detecting IgG4 & IgA showed the lowest cross-reactivity with sera from S. mansoni infected patients. So, assays detecting serum IgA, IgG1 & IgG4 against Fasciola ES antigens were highly sensitive and specific for diagnosis of fascioliasis and assays detecting salivary and faecal IgA were promising and of great help in diagnosis of fascioliasis especially in epidemiologic studies.

  4. Evaluation of multiplex assay platforms for detection of influenza hemagglutinin subtype specific antibody responses.

    PubMed

    Li, Zhu-Nan; Weber, Kimberly M; Limmer, Rebecca A; Horne, Bobbi J; Stevens, James; Schwerzmann, Joy; Wrammert, Jens; McCausland, Megan; Phipps, Andrew J; Hancock, Kathy; Jernigan, Daniel B; Levine, Min; Katz, Jacqueline M; Miller, Joseph D

    2017-05-01

    Influenza hemagglutination inhibition (HI) and virus microneutralization assays (MN) are widely used for seroprevalence studies. However, these assays have limited field portability and are difficult to fully automate for high throughput laboratory testing. To address these issues, three multiplex influenza subtype-specific antibody detection assays were developed using recombinant hemagglutinin antigens in combination with Chembio, Luminex ® , and ForteBio ® platforms. Assay sensitivity, specificity, and subtype cross-reactivity were evaluated using a panel of well characterized human sera. Compared to the traditional HI, assay sensitivity ranged from 87% to 92% and assay specificity in sera collected from unexposed persons ranged from 65% to 100% across the platforms. High assay specificity (86-100%) for A(H5N1) rHA was achieved for sera from exposed or unexposed to hetorosubtype influenza HAs. In contrast, assay specificity for A(H1N1)pdm09 rHA using sera collected from A/Vietnam/1204/2004 (H5N1) vaccinees in 2008 was low (22-30%) in all platforms. Although cross-reactivity against rHA subtype proteins was observed in each assay platform, the correct subtype specific responses were identified 78%-94% of the time when paired samples were available for analysis. These results show that high throughput and portable multiplex assays that incorporate rHA can be used to identify influenza subtype specific infections. Published by Elsevier B.V.

  5. Evaluation of SYBR green I based visual loop-mediated isothermal amplification (LAMP) assay for genus and species-specific diagnosis of malaria in P. vivax and P. falciparum endemic regions.

    PubMed

    Singh, Ruchi; Singh, Dhirendra Pratap; Savargaonkar, Deepali; Singh, Om P; Bhatt, Rajendra M; Valecha, Neena

    2017-01-01

    Loop-mediated isothermal amplification (LAMP) is an emerging nucleic acid based diag- nostic approach that is easily adaptable to the field settings with limited technical resources. This study was aimed to evaluate the LAMP assay for the detection and identification of Plasmodium falciparum and P. vivax infection in malaria suspected cases using genus and species-specific assay. The 18S rRNA-based LAMP assay was evaluated for diagnosis of genus Plasmodium, and species- specific diagnosis of P. falciparum and P. vivax, infection employing 317 malaria suspected cases, and the results were compared with those obtained by 18S nested PCR (n-PCR). All the samples were confirmed by microscopy for the presence of Plasmodium parasite. The n-PCR was positive in all Plasmodium-infected cases (n=257; P. falciparum=133; P. vivax=124) and negative in microscopy negative cases (n=58) except for two cases which were positive for P. vivax, giving a sen- sitivity of 100% (95% CI: 97.04-100%) and a specificity of 100% (95% CI: 88.45-99.5%). Genus-specific LAMP assay missed 11 (3.2%) microscopy and n-PCR confirmed vivax malaria cases. Considering PCR results as a refer- ence, LAMP was 100% sensitive and specific for P. falciparum, whereas it exhibited 95.16% sensitivity and 96.7% specificity for P. vivax. The n-PCR assay detected 10 mixed infection cases while species-specific LAMP detected five mixed infection cases of P. vivax and P. falciparum, which were not detected by microscopy. Genus-specific LAMP assay displayed low sensitivity. Falciparum specific LAMP assay displayed high sensitivity whereas vivax specific LAMP assay displayed low sensitivity. Failed detection of vivax cases otherwise confirmed by the n-PCR assay indicates exploitation of new targets and improved detection methods to attain 100% results for P. vivax detection.

  6. Direct detection of Leishmania from clinical samples.

    PubMed

    Waitumbi, John N; Bast, Joshua; Nyakoe, Nancy; Magiri, Charles; Quintana, Miguel; Takhampunya, Ratree; Schuster, Anthony L; Van de Wyngaerde, Marshall T; McAvin, James C; Coleman, Russell E

    2017-01-01

    The ability to rapidly and accurately diagnose leishmaniasis is a military priority. Testing was conducted to evaluate diagnostic sensitivity and specificity of field-expedient Leishmania genus and visceral Leishmania specific dual-fluorogenic, hydrolysis probe (TaqMan), polymerase chain reaction assays previously established for use in vector surveillance. Blood samples of patients with confirmed visceral leishmaniasis and controls without the disease from Baringo District, Kenya, were tested. Leishmania genus assay sensitivity was 100% (14/14) and specificity was 84% (16/19). Visceral Leishmania assay sensitivity was 93% (13/14) and specificity 80% (4/5). Cutaneous leishmaniasis (CL) skin scrapes of patients from Honduras were also evaluated. Leishmania genus assay sensitivity was 100% (10/10). Visceral Leishmania assay specificity was 100% (10/10) from cutaneous leishmaniasis samples; no fluorescence above background was reported. These results show promise in a rapid, sensitive, and specific method for Leishmania direct detection from clinical samples.

  7. Evaluating the diagnostic accuracy of the Xpert MTB/RIF assay on bronchoalveolar lavage fluid: A retrospective study.

    PubMed

    Lu, Yanjun; Zhu, Yaowu; Shen, Na; Tian, Lei; Sun, Ziyong

    2018-02-08

    Limited data on the diagnostic accuracy of the Xpert MTB/RIF assay using bronchoalveolar lavage fluid from patients with suspected pulmonary tuberculosis (PTB) have been reported in China. Therefore, a retrospective study was designed to evaluate the diagnostic accuracy of this assay. Clinical, radiological, and microbiological characteristics of 238 patients with suspected PTB were reviewed retrospectively. The sensitivity, specificity, positive predictive value, and negative predictive value for the diagnosis of active PTB were calculated for the Xpert MTB/RIF assay using TB culture or final diagnosis based on clinical and radiological evaluation as the reference standard. The sensitivity and specificity of the Xpert MTB/RIF assay were 84.5% and 98.9%, respectively, and those for smear microscopy were 36.2% and 100%, respectively, when compared to the culture method. However, compared with the sensitivity and specificity of final diagnosis based on clinical and radiological evaluation, the sensitivity and specificity of the assay were 72.9% and 98.7%, respectively, which were significantly higher than those for smear microscopy. The Xpert MTB/RIF assay on bronchoalveolar lavage fluid could serve as an additional rapid diagnostic tool for PTB in a high TB-burden country and improve the time to TB treatment initiation in patients with PTB. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  8. Evaluation of the COBAS Hepatitis C Virus (HCV) TaqMan analyte-specific reagent assay and comparison to the COBAS Amplicor HCV Monitor V2.0 and Versant HCV bDNA 3.0 assays.

    PubMed

    Konnick, Eric Q; Williams, Sheri M; Ashwood, Edward R; Hillyard, David R

    2005-05-01

    Performance characteristics of the COBAS hepatitis C virus (HCV) TaqMan analyte-specific reagent (TM-ASR) assay using the QIAGEN BioRobot 9604 for RNA extraction were evaluated and compared to the COBAS Amplicor HCV Monitor V2.0 (Amplicor) and Versant HCV bDNA 3.0 (Versant) assays using clinical samples. Calibration of TM-ASR using Armored RNA allowed determination of the distribution of HCV RNA in clinical samples, using 22,399 clinical samples. Limit of detection, linearity, and inter- and intraassay assay precision were determined for the TM-ASR assay using multiple clinical specimen panels across multiple determinations. Genotype specificity for the TM-ASR assay was determined using samples with different HCV RNA genotypes evaluated and compared against predetermined results. Contamination control of the TM-ASR assay was evaluated using pools of HCV RNA-positive and -negative samples tested in a checkerboard pattern over 12 runs of 96 samples. Correlation of the TM-ASR, Amplicor, and Versant assays was determined using 100 paired clinical samples and Deming regression analysis. The TM-ASR performed well with respect to linearity, precision, and contamination control. The correlation between TM-ASR and the Amplicor and Versant assays was poor, with large differences between assay results for individual samples. Calibration of the TM-ASR assay with Armored RNA allowed for a wide dynamic range and description of the distribution of HCV RNA in clinical samples.

  9. Evaluation of the COBAS Hepatitis C Virus (HCV) TaqMan Analyte-Specific Reagent Assay and Comparison to the COBAS Amplicor HCV Monitor V2.0 and Versant HCV bDNA 3.0 Assays

    PubMed Central

    Konnick, Eric Q.; Williams, Sheri M.; Ashwood, Edward R.; Hillyard, David R.

    2005-01-01

    Performance characteristics of the COBAS hepatitis C virus (HCV) TaqMan analyte-specific reagent (TM-ASR) assay using the QIAGEN BioRobot 9604 for RNA extraction were evaluated and compared to the COBAS Amplicor HCV Monitor V2.0 (Amplicor) and Versant HCV bDNA 3.0 (Versant) assays using clinical samples. Calibration of TM-ASR using Armored RNA allowed determination of the distribution of HCV RNA in clinical samples, using 22,399 clinical samples. Limit of detection, linearity, and inter- and intraassay assay precision were determined for the TM-ASR assay using multiple clinical specimen panels across multiple determinations. Genotype specificity for the TM-ASR assay was determined using samples with different HCV RNA genotypes evaluated and compared against predetermined results. Contamination control of the TM-ASR assay was evaluated using pools of HCV RNA-positive and -negative samples tested in a checkerboard pattern over 12 runs of 96 samples. Correlation of the TM-ASR, Amplicor, and Versant assays was determined using 100 paired clinical samples and Deming regression analysis. The TM-ASR performed well with respect to linearity, precision, and contamination control. The correlation between TM-ASR and the Amplicor and Versant assays was poor, with large differences between assay results for individual samples. Calibration of the TM-ASR assay with Armored RNA allowed for a wide dynamic range and description of the distribution of HCV RNA in clinical samples. PMID:15872232

  10. Evaluation of Two PCR-based Swine-specific Fecal Source Tracking Assays (Abstract)

    EPA Science Inventory

    Several PCR-based methods have been proposed to identify swine fecal pollution in environmental waters. However, the utility of these assays in identifying swine fecal contamination on a broad geographic scale is largely unknown. In this study, we evaluated the specificity, distr...

  11. EPA Critical Path Science Plan Projects 19, 20 and 21: Human and Bovine Source Detection

    EPA Science Inventory

    The U.S. EPA Critical Path Science Plan Projects are: Project 19: develop novel bovine and human host-specific PCR assays and complete performance evaluation with other published methods. Project 20: Evaluate human-specific assays with water samples impacted with different lev...

  12. Lipopolysaccharide Specific Immunochromatography Based Lateral Flow Assay for Serogroup Specific Diagnosis of Leptospirosis in India

    PubMed Central

    Vanithamani, Shanmugam; Shanmughapriya, Santhanam; Narayanan, Ramasamy; Raja, Veerapandian; Kanagavel, Murugesan; Sivasankari, Karikalacholan; Natarajaseenivasan, Kalimuthusamy

    2015-01-01

    Background Leptospirosis is a re-emerging infectious disease that is under-recognized due to low-sensitivity and cumbersome serological tests. MAT is the gold standard test and it is the only serogroup specific test used till date. Rapid reliable alternative serogroup specific tests are needed for surveillance studies to identify locally circulating serogroups in the study area. Methods/Principal Findings In the present investigation the serological specificity of leptospiral lipopolysaccharides (LPS) was evaluated by enzyme linked immunosorbent assay (ELISA), dot blot assay and rapid immunochromatography based lateral flow assay (ICG-LFA). Sera samples from 120 MAT positive cases, 174 cases with febrile illness other than leptospirosis, and 121 seronegative healthy controls were evaluated for the diagnostic sensitivity and specificity of the developed assays. LPS was extracted from five locally predominant circulating serogroups including: Australis (27.5%), Autumnalis (11.7%), Ballum (25.8%), Grippotyphosa (12.5%), Pomona (10%) and were used as antigens in the diagnostics to detect IgM antibodies in patients’ sera. The sensitivity observed by IgM ELISA and dot blot assay using various leptospiral LPS was >90% for homologous sera. Except for Ballum LPS, no other LPS showed cross-reactivity to heterologous sera. An attempt was made to develop LPS based ICG-LFA for rapid and sensitive serogroup specific diagnostics of leptospirosis. The developed ICG-LFA showed sensitivity in the range between 93 and 100% for homologous sera. The Wilcoxon analysis showed LPS based ICG-LFA did not differ significantly from the gold standard MAT (P>0.05). Conclusion The application of single array of LPS for serogroup specific diagnosis is first of its kind. The developed assay could potentially be evaluated and employed for as MAT alternative. PMID:26340095

  13. Incorporating expert judgments in utility evaluation of bacteroidales qPCR assays for microbial source tracking in a drinking water source.

    PubMed

    Åström, Johan; Pettersson, Thomas J R; Reischer, Georg H; Norberg, Tommy; Hermansson, Malte

    2015-02-03

    Several assays for the detection of host-specific genetic markers of the order Bacteroidales have been developed and used for microbial source tracking (MST) in environmental waters. It is recognized that the source-sensitivity and source-specificity are unknown and variable when introducing these assays in new geographic regions, which reduces their reliability and use. A Bayesian approach was developed to incorporate expert judgments with regional assay sensitivity and specificity assessments in a utility evaluation of a human and a ruminant-specific qPCR assay for MST in a drinking water source. Water samples from Lake Rådasjön were analyzed for E. coli, intestinal enterococci and somatic coliphages through cultivation and for human (BacH) and ruminant-specific (BacR) markers through qPCR assays. Expert judgments were collected regarding the probability of human and ruminant fecal contamination based on fecal indicator organism data and subjective information. Using Bayes formula, the conditional probability of a true human or ruminant fecal contamination given the presence of BacH or BacR was determined stochastically from expert judgments and regional qPCR assay performance, using Beta distributions to represent uncertainties. A web-based computational tool was developed for the procedure, which provides a measure of confidence to findings of host-specific markers and demonstrates the information value from these assays.

  14. Incorporating Expert Judgments in Utility Evaluation of Bacteroidales qPCR Assays for Microbial Source Tracking in a Drinking Water Source

    PubMed Central

    Åström, Johan; Pettersson, Thomas J. R.; Reischer, Georg H.; Norberg, Tommy; Hermansson, Malte

    2017-01-01

    Several assays for the detection of host-specific genetic markers of the order Bacteroidales have been developed and used for microbial source tracking (MST) in environmental waters. It is recognized that the source-sensitivity and source-specificity are unknown and variable when introducing these assays in new geographic regions, which reduces their reliability and use. A Bayesian approach was developed to incorporate expert judgments with regional assay sensitivity and specificity assessments in a utility evaluation of a human and a ruminant-specific qPCR assay for MST in a drinking water source. Water samples from Lake Rådasjön were analyzed for E. coli, intestinal enterococci and somatic coliphages through cultivation and for human (BacH) and ruminant-specific (BacR) markers through qPCR assays. Expert judgments were collected regarding the probability of human and ruminant fecal contamination based on fecal indicator organism data and subjective information. Using Bayes formula, the conditional probability of a true human or ruminant fecal contamination given the presence of BacH or BacR was determined stochastically from expert judgments and regional qPCR assay performance, using Beta distributions to represent uncertainties. A web-based computational tool was developed for the procedure, which provides a measure of confidence to findings of host-specific markers and demonstrates the information value from these assays. PMID:25545113

  15. Development of field-based real-time reverse transcription-polymerase chain reaction assays for detection of Chikungunya and O'nyong-nyong viruses in mosquitoes.

    PubMed

    Smith, Darci R; Lee, John S; Jahrling, Jordan; Kulesh, David A; Turell, Michael J; Groebner, Jennifer L; O'Guinn, Monica L

    2009-10-01

    Chikungunya (CHIK) and O'nyong-nyong (ONN) are important emerging arthropod-borne diseases. Molecular diagnosis of these two viruses in mosquitoes has not been evaluated, and the effects of extraneous mosquito tissue on assay performance have not been tested. Additionally, no real-time reverse transcription-polymerase chain reaction (RT-PCR) assay exists for detecting ONN virus (ONNV) RNA. We describe the development of sensitive and specific real-time RT-PCR assays for detecting CHIK and ONN viral RNA in mosquitoes, which have application for field use. In addition, we compared three methods for primer/probe design for assay development by evaluating their sensitivity and specificity. This comparison resulted in development of virus-specific assays that could detect less than one plaque-forming unit equivalent of each of the viruses in mosquitoes. The use of these assays will aid in arthropod-borne disease surveillance and in the control of the associated diseases.

  16. Development and evaluation of an immunochromatographic assay using a gp51 monoclonal antibody for the detection of antibodies against the bovine leukemia virus.

    PubMed

    Kim, Eun-Ju; Cheong, Kwang-Myun; Joung, Ha-Kyung; Kim, Bo-Hye; Song, Jae-Young; Cho, In-Soo; Lee, Kyoung-Ki; Shin, Yeun-Kyung

    2016-12-30

    Infection of cattle with bovine leukemia virus (BLV) has been observed and reported worldwide, including in Korea. The onsite identification of infected cattle would help decreasing and eradicating BLV infections on farms. Here, we present a new immunochromatographic assay that employs monoclonal antibodies (MAbs) for the detection of antibodies against BLV in the field. BLV envelope glycoprotein (gp)51 was expressed in E. coli , and MAbs against recombinant BLV gp51 were generated for the development of an immunochromatographic assay to detect BLV antibodies in cattle. The sensitivity and specificity of the assay were determined by comparing these results with those obtained from a standard enzyme linked immunosorbent assay (ELISA). A total of 160 bovine sera were used to evaluate the new immunochromatographic assay. Using ELISA as a reference standard, the relative specificity and sensitivity of this assay were determined to be 94.7% and 98%, respectively. Because of its high sensitivity and specificity, this BLV antibody detection assay would be suitable for the onsite identification of BLV infection in the field.

  17. Optimization and qualification of an Fc Array assay for assessments of antibodies against HIV-1/SIV.

    PubMed

    Brown, Eric P; Weiner, Joshua A; Lin, Shu; Natarajan, Harini; Normandin, Erica; Barouch, Dan H; Alter, Galit; Sarzotti-Kelsoe, Marcella; Ackerman, Margaret E

    2018-04-01

    The Fc Array is a multiplexed assay that assesses the Fc domain characteristics of antigen-specific antibodies with the potential to evaluate up to 500 antigen specificities simultaneously. Antigen-specific antibodies are captured on antigen-conjugated beads and their functional capacity is probed via an array of Fc-binding proteins including antibody subclassing reagents, Fcγ receptors, complement proteins, and lectins. Here we present the results of the optimization and formal qualification of the Fc Array, performed in compliance with Good Clinical Laboratory Practice (GCLP) guidelines. Assay conditions were optimized for performance and reproducibility, and the final version of the assay was then evaluated for specificity, accuracy, precision, limits of detection and quantitation, linearity, range and robustness. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Evaluation of the Alexon-Trend ProSpecT Campylobacter Microplate Assay

    PubMed Central

    Tolcin, Rita; LaSalvia, Margaret M.; Kirkley, Barbara A.; Vetter, Emily A.; Cockerill, Franklin R.; Procop, Gary W.

    2000-01-01

    We evaluated stool specimens known to contain or be free of Campylobacter by traditional culture, using the ProSpecT Campylobacter microplate assay (Alexon-Trend, Ramsey, Minn.). This rapid enzyme immunoassay for the detection of Campylobacter-specific antigens demonstrated 96% sensitivity and 99% specificity and is an acceptable alternative method of Campylobacter detection. PMID:11015419

  19. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    PubMed

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  20. Respiratory Syncytial Virus (RSV): Neutralizing Antibody, a Correlate of Immune Protection.

    PubMed

    Piedra, Pedro A; Hause, Anne M; Aideyan, Letisha

    2016-01-01

    Assays that measure RSV-specific neutralizing antibody activity are very useful for evaluating vaccine candidates, performing seroprevalence studies, and detecting infection. Neutralizing antibody activity is normally measured by a plaque reduction neutralization assay or by a microneutralization assay with or without complement. These assays measure the functional capacity of serum (or other fluids) to neutralize virus infectivity in cells as compared to ELISA assays that only measure the binding capacity against an antigen. This chapter discusses important elements in standardization of the RSV-specific microneutralization assay for use in the laboratory.

  1. Evaluation of the Elecsys Chagas Assay for Detection of Trypanosoma cruzi-Specific Antibodies in a Multicenter Study in Europe and Latin America.

    PubMed

    Flores-Chavez, Maria Delmans; Sambri, Vittorio; Schottstedt, Volkmar; Higuera-Escalante, Fernando Aparicio; Roessler, Dieter; Chaves, Monica; Laengin, Tina; Martinez, Alfredo; Fleischer, Bernhard

    2018-05-01

    Serology is the preferred method to confirm a Chagas disease diagnosis and to screen blood donors. A battery of assays is often required due to the limited accuracy of single assays. The Elecsys Chagas assay is a newly developed, double-antigen sandwich assay for use on the Elecsys and cobas e immunoassay analyzers, intended to identify individuals infected with Trypanosoma cruzi , for diagnosis and screening. The performance of the Elecsys Chagas assay was evaluated in comparison with those of other widely used T. cruzi antibody assays, at multiple sites (Europe/Latin America). Relative sensitivity and specificity were assessed by using samples from blood donors, pregnant women, and hospitalized patients from regions where Chagas disease is endemic and from regions of nonendemicity. The Elecsys Chagas assay had an overall relative sensitivity of 100% ( n = 674). Overall relative specificities were 99.90% ( n = 14,681), 100% ( n = 313), and 100% ( n = 517) for samples from blood donors, pregnant women, and hospitalized patients, respectively. The analytical specificity was 99.83% ( n = 594). The Elecsys Chagas assay detected T. cruzi antibodies in two World Health Organization (WHO) standard T. cruzi reference panels (panels 09/188 and 09/186) at a 1:512 dilution, corresponding to a cutoff sensitivity of approximately 1 mIU/ml. The Elecsys Chagas assay demonstrated robust performance under routine conditions at multiple sites in Europe and Latin America. In contrast to other available Chagas assays, the Elecsys assay uses a reduced number of recombinant T. cruzi antigens, resulting in a significantly smaller number of cross-reactions and improved analytical specificity while being highly sensitive. Copyright © 2018 Flores-Chavez et al.

  2. Evaluation of the Elecsys Chagas Assay for Detection of Trypanosoma cruzi-Specific Antibodies in a Multicenter Study in Europe and Latin America

    PubMed Central

    Sambri, Vittorio; Schottstedt, Volkmar; Higuera-Escalante, Fernando Aparicio; Roessler, Dieter; Chaves, Monica; Laengin, Tina; Martinez, Alfredo; Fleischer, Bernhard

    2018-01-01

    ABSTRACT Serology is the preferred method to confirm a Chagas disease diagnosis and to screen blood donors. A battery of assays is often required due to the limited accuracy of single assays. The Elecsys Chagas assay is a newly developed, double-antigen sandwich assay for use on the Elecsys and cobas e immunoassay analyzers, intended to identify individuals infected with Trypanosoma cruzi, for diagnosis and screening. The performance of the Elecsys Chagas assay was evaluated in comparison with those of other widely used T. cruzi antibody assays, at multiple sites (Europe/Latin America). Relative sensitivity and specificity were assessed by using samples from blood donors, pregnant women, and hospitalized patients from regions where Chagas disease is endemic and from regions of nonendemicity. The Elecsys Chagas assay had an overall relative sensitivity of 100% (n = 674). Overall relative specificities were 99.90% (n = 14,681), 100% (n = 313), and 100% (n = 517) for samples from blood donors, pregnant women, and hospitalized patients, respectively. The analytical specificity was 99.83% (n = 594). The Elecsys Chagas assay detected T. cruzi antibodies in two World Health Organization (WHO) standard T. cruzi reference panels (panels 09/188 and 09/186) at a 1:512 dilution, corresponding to a cutoff sensitivity of approximately 1 mIU/ml. The Elecsys Chagas assay demonstrated robust performance under routine conditions at multiple sites in Europe and Latin America. In contrast to other available Chagas assays, the Elecsys assay uses a reduced number of recombinant T. cruzi antigens, resulting in a significantly smaller number of cross-reactions and improved analytical specificity while being highly sensitive. PMID:29444836

  3. A Novel Assay for the Identification of NOTCH1 PEST Domain Mutations in Chronic Lymphocytic Leukemia

    PubMed Central

    Petroni, Roberta Cardoso; Muto, Nair Hideko; Sitnik, Roberta; de Carvalho, Flavia Pereira; Bacal, Nydia Strachman; Velloso, Elvira Deolinda Rodrigues Pereira; Oliveira, Gislaine Borba; Pinho, João Renato Rebello; Torres, Davi Coe; Mansur, Marcela Braga; Hassan, Rocio; Lorand-Metze, Irene Gyongyvér Heidemarie; Chiattone, Carlos Sérgio; Hamerschlak, Nelson; Mangueira, Cristovão Luis Pitangueira

    2016-01-01

    Aims. To develop a fast and robust DNA-based assay to detect insertions and deletions mutations in exon 34 that encodes the PEST domain of NOTCH1 in order to evaluate patients with chronic lymphocytic leukemia (CLL). Methods. We designed a multiplexed allele-specific polymerase chain reaction (PCR) combined with a fragment analysis assay to detect specifically the mutation c.7544_7545delCT and possibly other insertions and deletions in exon 34 of NOTCH1. Results. We evaluated our assay in peripheral blood samples from two cohorts of patients with CLL. The frequency of NOTCH1 mutations was 8.4% in the first cohort of 71 unselected CLL patients. We then evaluated a second cohort of 26 CLL patients with known cytogenetic abnormalities that were enriched for patients with trisomy 12. NOTCH1 mutations were detected in 43.7% of the patients with trisomy 12. Conclusions. We have developed a fast and robust assay combining allele-specific PCR and fragment analysis able to detect NOTCH1 PEST domain insertions and deletions. PMID:28074183

  4. Comprehensive Laboratory Evaluation of a Highly Specific Lateral Flow Assay for the Presumptive Identification of Bacillus anthracis Spores in Suspicious White Powders and Environmental Samples

    PubMed Central

    Ramage, Jason G.; Prentice, Kristin W.; DePalma, Lindsay; Venkateswaran, Kodumudi S.; Chivukula, Sruti; Chapman, Carol; Bell, Melissa; Datta, Shomik; Singh, Ajay; Hoffmaster, Alex; Sarwar, Jawad; Parameswaran, Nishanth; Joshi, Mrinmayi; Thirunavkkarasu, Nagarajan; Krishnan, Viswanathan; Morse, Stephen; Avila, Julie R.; Sharma, Shashi; Estacio, Peter L.; Stanker, Larry; Hodge, David R.

    2016-01-01

    We conducted a comprehensive, multiphase laboratory evaluation of the Anthrax BioThreat Alert® test strip, a lateral flow immunoassay (LFA) for the rapid detection of Bacillus anthracis spores. The study, conducted at 2 sites, evaluated this assay for the detection of spores from the Ames and Sterne strains of B. anthracis, as well as those from an additional 22 strains. Phylogenetic near neighbors, environmental background organisms, white powders, and environmental samples were also tested. The Anthrax LFA demonstrated a limit of detection of about 106 spores/mL (ca. 1.5 × 105 spores/assay). In this study, overall sensitivity of the LFA was 99.3%, and the specificity was 98.6%. The results indicated that the specificity, sensitivity, limit of detection, dynamic range, and repeatability of the assay support its use in the field for the purpose of qualitatively evaluating suspicious white powders and environmental samples for the presumptive presence of B. anthracis spores. PMID:27661796

  5. Development of a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of common genetically modified organisms (GMOs).

    PubMed

    Feng, Jiawang; Tang, Shiming; Liu, Lideng; Kuang, Xiaoshan; Wang, Xiaoyu; Hu, Songnan; You, Shuzhu

    2015-03-01

    Here, we developed a loop-mediated isothermal amplification (LAMP) assay for 11 common transgenic target DNA in GMOs. Six sets of LAMP primer candidates for each target were designed and their specificity, sensitivity, and reproductivity were evaluated. With the optimized LAMP primers, this LAMP assay was simply run within 45-60 min to detect all these targets in GMOs tested. The sensitivity, specificity, and reproductivity of the LAMP assay were further analyzed in comparison with those of Real-Time PCR. In consistent with real-time PCR, detection of 0.5% GMOs in equivalent background DNA was possible using this LAMP assay for all targets. In comparison with real-time PCR, the LAMP assay showed the same results with simple instruments. Hence, the LAMP assay developed can provide a rapid and simple approach for routine screening as well as specific events detection of many GMOs.

  6. Clinical Evaluation of Fully Automated Elecsys® Syphilis Assay for the Detection of Antibodies of Treponema pallidum.

    PubMed

    Li, Dongdong; An, Jingna; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2016-11-01

    The resurgence of syphilis in recent years has become a serious threat to the public health worldwide, and the serological detection of specific antibodies against Treponema pallidum (TP) remains the most reliable method for laboratory diagnosis of syphilis. The performance of the Elecsys ® Syphilis assay, a brand new electrochemiluminescene immunoassay (ECLIA), was assessed by large amounts of samples in this study. In comparison with InTec assay, the Elecsys ® Syphilis assay was evaluated in 146 preselected samples from patients with syphilis, 1803 clinical routine samples, and 175 preselected samples from specific populations with reportedly increased rates of false-positive syphilis test results. Discrepancy samples must be investigated by Mikrogen Syphilis recomline assay. There was an overall agreement of 99.58% between two assays (Kappa = 0.975). The sensitivity and specificity of the Elecsys ® Syphilis assay were 100.0% (95% CI, 96.8-100.0%) and 99.8% (95% CI, 99.5-100.0%), respectively. The Elecsys syphilis assay displays better sensitivity (100%), specificity (99.8%), PPV (98.7%), and NPV (100%) in 2124 samples enrolled, compared with the InTec assay. Considering the excellent ease of use and automation, high throughput, and its superior sensitivity, especially in primary syphilis, the Elecsys ® Syphilis assay could represent an outstanding choice for screening of syphilis in high-volume laboratories. However, more attention was still needed, or the results must be confirmed by other treponemal immunoassays. The new Elecsys ® Syphilis assay is applied to patients with malignant neoplasm or HIV infection. © 2016 Wiley Periodicals, Inc.

  7. A nonradioactive assay for poly(a)-specific ribonuclease activity by methylene blue colorimetry.

    PubMed

    Cheng, Yuan; Liu, Wei-Feng; Yan, Yong-Bin; Zhou, Hai-Meng

    2006-01-01

    A simple nonradioactive assay, which was based on the specific shift of the absorbance maximum of methylene blue induced by its intercalation into poly(A) molecules, was developed for poly(A)-specific ribonuclease (PARN). A good linear relationship was found between the absorbance at 662 nm and the poly(A) concentration. The assay conditions, including the concentration of methylene blue, the incubation temperature and time, and the poly(A) concentration were evaluated and optimized.

  8. Comparative evaluation of post-column free radical scavenging and ferric reducing antioxidant power assays for screening of antioxidants in strawberries.

    PubMed

    Raudonis, Raimondas; Raudone, Lina; Jakstas, Valdas; Janulis, Valdimaras

    2012-04-13

    ABTS and FRAP post-column techniques evaluate the antioxidant characteristics of HPLC separated compounds with specific reagents. ABTS characterize their ability to scavenge free radicals by electron-donating antioxidants, resulting in the absorbance decrease of the chromophoric radical. FRAP - is based on the reduction of Fe(III)-tripyridyltriazine complex to Fe(II)-tripyridyltriazine at low pH by electron-donating antioxidants, resulting in an absorbance increase. Both post-column assays were evaluated and compared according to the following validation parameters: specificity, precision, limit of detection (LoD), limit of quantitation (LoQ) and linearity. ABTS and FRAP post-column assays were specific, repeatable and sensitive and thus can be used for the evaluation of antioxidant active compounds. Antioxidant active compounds were quantified according to TEAC for each assay and ABTS/FRAP ratio was derived. No previous records of antioxidative activity of leaves and fruits of strawberries (Fragaria viridis, Fragaria moschata) research have been found. The research results confirm the reliability of ABTS and FRAP post-column assays for screening of antioxidants in complex mixtures and the determination of radical scavenging and ferric reducing ability by their TEAC values. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Evaluation of Two PCR-Based Swine-Specific Fecal Source Tracking Assays (Poster)

    EPA Science Inventory

    Several PCR-based methods have been proposed to identify swine fecal pollution in environmental waters. However, the specificity and distribution of these targets have not been adequately assessed. Consequently, the utility of these assays in identifying swine fecal contamination...

  10. Before In Vivo Imaging: Evaluation of Fluorescent Probes Using Fluorescence Microscopy, Multiplate Reader, and Cytotoxicity Assays.

    PubMed

    Zhang, Shaojuan

    2016-01-01

    Fluorescent probes are widely utilized for noninvasive fluorescence imaging. Continuing efforts have been made in developing novel fluorescent probes with improved fluorescence quantum yield, enhanced target-specificity, and lower cytotoxicity. Before such probes are administrated into a living system, it is essential to evaluate the subcellular uptake, targeting specificity, and cytotoxicity in vitro. In this chapter, we briefly outline common methods used to evaluate fluorescent probes using fluorescence microscopy, multiplate reader, and cytotoxicity assay.

  11. Evaluation of two new automated chemiluminescent assays (HemosIL® AcuStar HIT-IgG and HemosIL® AcuStar HIT-Ab) for the detection of heparin-induced antibodies in the diagnosis of heparin-induced thrombocytopenia.

    PubMed

    Van Hoecke, F; Devreese, K

    2012-08-01

    Recently, two new, fully automated quantitative chemiluminescent immunoassays, the HemosIL(®) AcuStar HIT-IgG (PF4-H), specific for IgG anti-PF4/H antibodies, and the HemosIL(®) AcuStar HIT-Ab(PF4-H), detecting IgG, IgM and IgA anti-PF4/H antibodies, were introduced into the market. In this study, their performance was compared mutually and with the Zymutest HIA IgG and HIA IgGAM ELISA. Citrated plasmas from 87 patients with clinical suspicion of heparin-induced thrombocytopenia (HIT) were analyzed with all four assays and with a functional confirmation assay. Apart from the manufacturer's cutoffs, optimalized cutoffs were evaluated as well. Sensitivities of all assays were 100%. The Acustar HIT-IgG assay showed a higher specificity compared with the HIT-Ab assay (85%vs. 73%), using the manufacturer's cutoffs. Specificities of all assays, except for the AcuStar HIT-IgG, could be significantly improved when altering the cutoff. Titers were significantly higher for the HIT-Ab assay compared with the HIT-IgG assay (P = 0.0001). This was also the case for the patients with confirmed HIT (P = 0.0495), indicating that the one cutoff (1.0 OD) for both Acustar assays, as proposed by the manufacturer, can be adapted for the AcuStar Hit-Ab assay resulting in an increased specificity. Performance characteristics of the Acustar HIT-IgG and HIT-Ab assay are comparable to the Zymutest HIA IgG and HIA IgGAM. © 2012 Blackwell Publishing Ltd.

  12. Clinical evaluation of the new Roche platform of serological and molecular cytomegalovirus-specific assays in the diagnosis and prognosis of congenital cytomegalovirus infection.

    PubMed

    Chiereghin, Angela; Pavia, Claudia; Gabrielli, Liliana; Piccirilli, Giulia; Squarzoni, Diego; Turello, Gabriele; Gibertoni, Dino; Simonazzi, Giuliana; Capretti, Maria Grazia; Lanari, Marcello; Lazzarotto, Tiziana

    2017-10-01

    Clinical evaluation of the Elecsys ® CMV IgM, IgG, IgG Avidity and COBAS AmpliPrep/COBAS TaqMan CMV (COBAS CMV) assays (Roche Diagnostics AG) in the diagnosis and prognosis of congenital CMV infection was performed. In this study, 150 preselected clinical samples (50 primary infection sera, 50 amniotic fluid [AF] and 50 newborn urine) were processed using Roche serological/molecular CMV-specific tests. Results were compared with those obtained by routine assays (comparator assays). The Elecsys ® CMV IgM and IgG assays showed a perfect agreement (100%) with the comparator assays. Using the combination of the Elecsys ® CMV IgM and IgG Avidity assays results, a primary infection was identified in 100% of cases. Inappropriate avidity CMV IgG values in two samples with very low IgG values (<6 AU/mL) were observed. COBAS CMV assay showed an agreement equal to 98% and 100% with comparator assays by processing AF and urine samples, respectively. Among AF with quantitative results, Lin's concordance correlation was 0.933 and comparator-COBAS CMV assays gave CMV-DNA loads differing by <0.5 log 10 DNA. Finally, higher CMV-DNA levels in AF samples were associated with a symptomatic outcome (p=0.003). The Roche CMV-specific assays compared well with the comparator assays, thus providing to be suitable for clinical use. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Development and evaluation of tailored specific real-time RT-PCR assays for detection of foot-and-mouth disease virus serotypes circulating in East Africa.

    PubMed

    Bachanek-Bankowska, Katarzyna; Mero, Herieth R; Wadsworth, Jemma; Mioulet, Valerie; Sallu, Raphael; Belsham, Graham J; Kasanga, Christopher J; Knowles, Nick J; King, Donald P

    2016-11-01

    Rapid, reliable and accurate diagnostic methods provide essential support to programmes that monitor and control foot-and-mouth disease (FMD). While pan-specific molecular tests for FMD virus (FMDV) detection are well established and widely used in endemic and FMD-free countries, current serotyping methods mainly rely either on antigen detection ELISAs or nucleotide sequencing approaches. This report describes the development of a panel of serotype-specific real-time RT-PCR assays (rRT-PCR) tailored to detect FMDV lineages currently circulating in East Africa. These assays target sequences within the VP1-coding region that share high intra-lineage identity, but do not cross-react with FMD viruses from other serotypes that circulate in the region. These serotype-specific assays operate with the same thermal profile as the pan-diagnostic tests making it possible to run them in parallel to produce C T values comparable to the pan-diagnostic test detecting the 3D-coding region. These assays were evaluated alongside the established pan-specific molecular test using field samples and virus isolates collected from Tanzania, Kenya and Ethiopia that had been previously characterised by nucleotide sequencing. Samples (n=71) representing serotype A (topotype AFRICA, lineage G-I), serotype O (topotypes EA-2 and EA-4), serotype SAT 1 (topotype I (NWZ)) and serotype SAT2 (topotype IV) were correctly identified with these rRT-PCR assays. Furthermore, FMDV RNA from samples that did not contain infectious virus could still be serotyped using these assays. These serotype-specific real-time RT-PCR assays can detect and characterise FMDVs currently circulating in East Africa and hence improve disease control in this region. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Evaluation of enzyme-linked immunosorbent and alternative assays for detection of HIV antibodies using panels of Brazilian sera.

    PubMed

    Ivo-Dos-Santos, J; Mello, D L; Couto-Fernandez, J C; Passos, R M; Dias-Carneiro, L A; Castilho, E A; Galvão-Castro, B

    1990-01-01

    Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.

  15. Duplex recombinase polymerase amplification assays incorporating competitive internal controls for bacterial meningitis detection.

    PubMed

    Higgins, Owen; Clancy, Eoin; Forrest, Matthew S; Piepenburg, Olaf; Cormican, Martin; Boo, Teck Wee; O'Sullivan, Nicola; McGuinness, Claire; Cafferty, Deirdre; Cunney, Robert; Smith, Terry J

    2018-04-01

    Recombinase polymerase amplification (RPA) is an isothermal nucleic acid amplification technology that provides rapid and robust infectious disease pathogen detection, ideal for point-of-care (POC) diagnostics in disease-prevalent low-resource countries. We have developed and evaluated three duplex RPA assays incorporating competitive internal controls for the detection of leading bacterial meningitis pathogens. Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae singleplex RPA assays were initially developed and evaluated, demonstrating 100% specificity with limits of detection of 4.1, 8.5 and 3.9 genome copies per reaction, respectively. Each assay was further developed into internally controlled duplex RPA assays via the incorporation of internal amplification control templates. Clinical performance of each internally controlled duplex RPA assay was evaluated by testing 64 archived PCR-positive clinical samples. Compared to real-time PCR, all duplex RPA assays demonstrated 100% diagnostic specificity, with diagnostic sensitivities of 100%, 86.3% and 100% for the S. pneumoniae, N. meningitidis and H. influenzae assays, respectively. This study details the first report of internally controlled duplex RPA assays for the detection of bacterial meningitis pathogens: S. pneumoniae, N. meningitidis and H. influenzae. We have successfully demonstrated the clinical diagnostic utility of each duplex RPA assay, introducing effective diagnostic technology for POC bacterial meningitis identification in disease-prevalent developing countries. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Rapid detection and quantification of Ebola Zaire virus by one-step real-time quantitative reverse transcription-polymerase chain reaction.

    PubMed

    Ro, Young-Tae; Ticer, Anysha; Carrion, Ricardo; Patterson, Jean L

    2017-04-01

    Given that Ebola virus causes severe hemorrhagic fever in humans with mortality rates as high as 90%, rapid and accurate detection of this virus is essential both for controlling infection and preventing further transmission. Here, a one-step qRT-PCR assay for rapid and quantitative detection of an Ebola Zaire strain using GP, VP24 or VP40 genes as a target is introduced. Routine assay conditions for hydrolysis probe detection were established from the manufacturer's protocol used in the assays. The analytical specificity and sensitivity of each assay was evaluated using in vitro synthesized viral RNA transcripts. The assays were highly specific for the RNA transcripts, no cross-reactivity being observed among them. The limits of detection of the assays ranged from 10 2 to 10 3 copies per reaction. The assays were also evaluated using viral RNAs extracted from cell culture-propagated viruses (Ebola Zaire, Sudan and Reston strains), confirming that they are gene- and strain-specific. The RT-PCR assays detected viral RNAs in blood samples from virus-infected animal, suggesting that they can be also a useful method for identifying Ebola virus in clinical samples. © 2017 The Societies and John Wiley & Sons Australia, Ltd.

  17. Evaluation of a human neurite growth assay as specific screen for developmental neurotoxicants.

    PubMed

    Krug, Anne K; Balmer, Nina V; Matt, Florian; Schönenberger, Felix; Merhof, Dorit; Leist, Marcel

    2013-12-01

    Organ-specific in vitro toxicity assays are often highly sensitive, but they lack specificity. We evaluated here examples of assay features that can affect test specificity, and some general procedures are suggested on how positive hits in complex biological assays may be defined. Differentiating human LUHMES cells were used as potential model for developmental neurotoxicity testing. Forty candidate toxicants were screened, and several hits were obtained and confirmed. Although the cells had a definitive neuronal phenotype, the use of a general cell death endpoint in these cultures did not allow specific identification of neurotoxicants. As alternative approach, neurite growth was measured as an organ-specific functional endpoint. We found that neurite extension of developing LUHMES was specifically inhibited by diverse compounds such as colchicine, vincristine, narciclasine, rotenone, cycloheximide, or diquat. These compounds reduced neurite growth at concentrations that did not compromise cell viability, and neurite growth was affected more potently than the integrity of developed neurites of mature neurons. A ratio of the EC50 values of neurite growth inhibition and cell death of >4 provided a robust classifier for compounds associated with a developmental neurotoxic hazard. Screening of unspecific toxicants in the test system always yielded ratios <4. The assay identified also compounds that accelerated neurite growth, such as the rho kinase pathway modifiers blebbistatin or thiazovivin. The negative effects of colchicine or rotenone were completely inhibited by a rho kinase inhibitor. In summary, we suggest that assays using functional endpoints (neurite growth) can specifically identify and characterize (developmental) neurotoxicants.

  18. Comprehensive Multiplex One-Step Real-Time TaqMan qRT-PCR Assays for Detection and Quantification of Hemorrhagic Fever Viruses

    PubMed Central

    Li, Jiandong; Qu, Jing; He, Chengcheng; Zhang, Shuo; Li, Chuan; Zhang, Quanfu; Liang, Mifang; Li, Dexin

    2014-01-01

    Background Viral hemorrhagic fevers (VHFs) are a group of animal and human illnesses that are mostly caused by several distinct families of viruses including bunyaviruses, flaviviruses, filoviruses and arenaviruses. Although specific signs and symptoms vary by the type of VHF, initial signs and symptoms are very similar. Therefore rapid immunologic and molecular tools for differential diagnosis of hemorrhagic fever viruses (HFVs) are important for effective case management and control of the spread of VHFs. Real-time quantitative reverse transcriptase-polymerase chain reaction (qRT-PCR) assay is one of the reliable and desirable methods for specific detection and quantification of virus load. Multiplex PCR assay has the potential to produce considerable savings in time and resources in the laboratory detection. Results Primers/probe sets were designed based on appropriate specific genes for each of 28 HFVs which nearly covered all the HFVs, and identified with good specificity and sensitivity using monoplex assays. Seven groups of multiplex one-step real-time qRT-PCR assays in a universal experimental system were then developed by combining all primers/probe sets into 4-plex reactions and evaluated with serial dilutions of synthesized viral RNAs. For all the multiplex assays, no cross-reactivity with other HFVs was observed, and the limits of detection were mainly between 45 and 150 copies/PCR. The reproducibility was satisfactory, since the coefficient of variation of Ct values were all less than 5% in each dilution of synthesized viral RNAs for both intra-assays and inter-assays. Evaluation of the method with available clinical serum samples collected from HFRS patients, SFTS patients and Dengue fever patients showed high sensitivity and specificity of the related multiplex assays on the clinical specimens. Conclusions Overall, the comprehensive multiplex one-step real-time qRT-PCR assays were established in this study, and proved to be specific, sensitive, stable and easy to serve as a useful tool for rapid detection of HFVs. PMID:24752452

  19. HIV RNA testing in the context of nonoccupational postexposure prophylaxis.

    PubMed

    Roland, Michelle E; Elbeik, Tarek A; Kahn, James O; Bamberger, Joshua D; Coates, Thomas J; Krone, Melissa R; Katz, Mitchell H; Busch, Michael P; Martin, Jeffrey N

    2004-08-01

    The specificity and positive predictive value of human immunodeficiency virus (HIV) RNA assays have not been evaluated in the setting of postexposure prophylaxis (PEP). Plasma from subjects enrolled in a nonoccupational PEP study was tested with 2 branched-chain DNA (bDNA) assays, 2 polymerase chain reaction (PCR) assays, and a transcription-mediated amplification (TMA) assay. Assay specificity and positive predictive value were determined for subjects who remained negative for HIV antibody for >or=3 months. In 329 subjects examined, the lowest specificities (90.1%-93.7%) were seen for bDNA testing performed in real time. The highest specificities were seen with batched bDNA version 3.0 (99.1%), standard PCR (99.4%), ultrasensitive PCR (100%), and TMA (99.6%) testing. Only the 2 assays with the highest specificities had positive predictive values >40%. For the bDNA assays, increasing the cutoff point at which a test is called positive (e.g., from 50 copies/mL to 500 copies/mL for version 3.0) increased both specificity and positive predictive values to 100%. The positive predictive value of HIV RNA assays in individuals presenting for PEP is unacceptably low for bDNA-based testing and possibly acceptable for PCR- and TMA-based testing. Routine use of HIV RNA assays in such individuals is not recommended.

  20. COMPARING THE SOLID PHASE AND SALINE EXTRACT MICROTOX(R) ASSAYS FOR TWO PAH CONTAMINATED SOILS

    EPA Science Inventory

    The performance of remedial treatments is typically evaluated by measuring the concentration of specific chemicals. By adding toxicity bioassays to treatment evaluations, a fuller understanding of treatment performance is obtained. The solid phase Microtox assay is one potenti...

  1. Evaluation of an Internally Controlled Multiplex Tth Endonuclease Cleavage Loop-Mediated Isothermal Amplification (TEC-LAMP) Assay for the Detection of Bacterial Meningitis Pathogens

    PubMed Central

    Clancy, Eoin; Cormican, Martin; Boo, Teck Wee; Cunney, Robert

    2018-01-01

    Bacterial meningitis infection is a leading global health concern for which rapid and accurate diagnosis is essential to reduce associated morbidity and mortality. Loop-mediated isothermal amplification (LAMP) offers an effective low-cost diagnostic approach; however, multiplex LAMP is difficult to achieve, limiting its application. We have developed novel real-time multiplex LAMP technology, TEC-LAMP, using Tth endonuclease IV and a unique LAMP primer/probe. This study evaluates the analytical specificity, limit of detection (LOD) and clinical application of an internally controlled multiplex TEC-LAMP assay for detection of leading bacterial meningitis pathogens: Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae. Analytical specificities were established by testing 168 bacterial strains, and LODs were determined using Probit analysis. The TEC-LAMP assay was 100% specific, with LODs for S. pneumoniae, N. meningitidis and H. influenzae of 39.5, 17.3 and 25.9 genome copies per reaction, respectively. Clinical performance was evaluated by testing 65 archived PCR-positive samples. Compared to singleplex real-time PCR, the multiplex TEC-LAMP assay demonstrated diagnostic sensitivity and specificity of 92.3% and 100%, respectively. This is the first report of a single-tube internally controlled multiplex LAMP assay for bacterial meningitis pathogen detection, and the first report of Tth endonuclease IV incorporation into nucleic acid amplification diagnostic technology. PMID:29425124

  2. Evaluation of an Internally Controlled Multiplex Tth Endonuclease Cleavage Loop-Mediated Isothermal Amplification (TEC-LAMP) Assay for the Detection of Bacterial Meningitis Pathogens.

    PubMed

    Higgins, Owen; Clancy, Eoin; Cormican, Martin; Boo, Teck Wee; Cunney, Robert; Smith, Terry J

    2018-02-09

    Bacterial meningitis infection is a leading global health concern for which rapid and accurate diagnosis is essential to reduce associated morbidity and mortality. Loop-mediated isothermal amplification (LAMP) offers an effective low-cost diagnostic approach; however, multiplex LAMP is difficult to achieve, limiting its application. We have developed novel real-time multiplex LAMP technology, TEC-LAMP, using Tth endonuclease IV and a unique LAMP primer/probe. This study evaluates the analytical specificity, limit of detection (LOD) and clinical application of an internally controlled multiplex TEC-LAMP assay for detection of leading bacterial meningitis pathogens: Streptococcus pneumoniae , Neisseria meningitidis and Haemophilus influenzae . Analytical specificities were established by testing 168 bacterial strains, and LODs were determined using Probit analysis. The TEC-LAMP assay was 100% specific, with LODs for S. pneumoniae , N. meningitidis and H. influenzae of 39.5, 17.3 and 25.9 genome copies per reaction, respectively. Clinical performance was evaluated by testing 65 archived PCR-positive samples. Compared to singleplex real-time PCR, the multiplex TEC-LAMP assay demonstrated diagnostic sensitivity and specificity of 92.3% and 100%, respectively. This is the first report of a single-tube internally controlled multiplex LAMP assay for bacterial meningitis pathogen detection, and the first report of Tth endonuclease IV incorporation into nucleic acid amplification diagnostic technology.

  3. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    PubMed

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA Centaur HBV assays resulted in no change in interpretation of the results. Assay performance was further evaluated using HBV seroconversion panels with comparable or better results when compared to the comparison assays. The performance evaluation data demonstrate that the ADVIA Centaur HBV assays are specific and sensitive automated immunoassays for detection of antigens and antibodies to hepatitis B virus with performance that is comparable to those of currently marketed assays. Additionally, these assays have the advantage of being available on the ADVIA Centaur immunoassay system, which provides for the flexibility of high throughput and full automation.

  4. Development of an LC-MS based enzyme activity assay for MurC: application to evaluation of inhibitors and kinetic analysis.

    PubMed

    Deng, Gejing; Gu, Rong-Fang; Marmor, Stephen; Fisher, Stewart L; Jahic, Haris; Sanyal, Gautam

    2004-06-29

    An enzyme activity assay, based on mass spectrometric (MS) detection of specific reaction product following HPLC separation, has been developed to evaluate pharmaceutical hits identified from primary high throughput screening (HTS) against target enzyme Escherichia coli UDP-N-acetyl-muramyl-L-alanine ligase (MurC), an essential enzyme in the bacterial peptidoglycan biosynthetic pathway, and to study the kinetics of the enzyme. A comparative analysis of this new liquid chromatographic-MS (LC-MS) based assay with a conventional spectrophotometric Malachite Green (MG) assay, which detects phosphate produced in the reaction, was performed. The results demonstrated that the LC-MS assay, which determines specific ligase activity of MurC, offers several advantages including a lower background (0.2% versus 26%), higher sensitivity (> or = 10 fold), lower limit of quantitation (LOQ) (0.02 microM versus 1 microM) and wider linear dynamic range (> or = 4 fold) than the MG assay. Good precision for the LC-MS assay was demonstrated by the low intraday and interday coefficient of variation (CV) values (3 and 6%, respectively). The LC-MS assay, free of the artifacts often seen in the Malachite Green assay, offers a valuable secondary assay for hit evaluation in which the false positives from the primary high throughput screening can be eliminated. In addition, the applicability of this assay to the study of enzyme kinetics has also been demonstrated. Copyright 2004 Elsevier B.V.

  5. The Diagnostic Performance of Stool DNA Testing for Colorectal Cancer: A Systematic Review and Meta-Analysis.

    PubMed

    Zhai, Rong-Lin; Xu, Fei; Zhang, Pei; Zhang, Wan-Li; Wang, Hui; Wang, Ji-Liang; Cai, Kai-Lin; Long, Yue-Ping; Lu, Xiao-Ming; Tao, Kai-Xiong; Wang, Guo-Bin

    2016-02-01

    This meta-analysis was designed to evaluate the diagnostic performance of stool DNA testing for colorectal cancer (CRC) and compare the performance between single-gene and multiple-gene tests.MEDLINE, Cochrane, EMBASE databases were searched using keywords colorectal cancers, stool/fecal, sensitivity, specificity, DNA, and screening. Sensitivity analysis, quality assessments, and performance bias were performed for the included studies.Fifty-three studies were included in the analysis with a total sample size of 7524 patients. The studies were heterogeneous with regard to the genes being analyzed for fecal genetic biomarkers of CRC, as well as the laboratory methods being used for each assay. The sensitivity of the different assays ranged from 2% to 100% and the specificity ranged from 81% to 100%. The meta-analysis found that the pooled sensitivities for single- and multigene assays were 48.0% and 77.8%, respectively, while the pooled specificities were 97.0% and 92.7%. Receiver operator curves and diagnostic odds ratios showed no significant difference between both tests with regard to sensitivity or specificity.This meta-analysis revealed that using assays that evaluated multiple genes compared with single-gene assays did not increase the sensitivity or specificity of stool DNA testing in detecting CRC.

  6. The recomBead Borrelia antibody index, CXCL13 and total IgM index for laboratory diagnosis of Lyme neuroborreliosis in children.

    PubMed

    Skogman, B H; Lager, M; Henningsson, A J; Tjernberg, I

    2017-11-01

    For laboratory diagnostics of Lyme neuroborreliosis (LNB), the recomBead Borrelia antibody index (AI) assay has shown promising results in a mixed age population, but has not previously been evaluated with specific focus on paediatric patients. The aim of the study was to evaluate the recomBead Borrelia AI assay in cerebrospinal fluid (CSF) for the laboratory diagnosis of LNB in children. We also wanted to explore whether early markers, such as CXCL13 in CSF and/or total IgM index could be useful as complementary diagnostic tools. Children being evaluated for LNB in a Swedish Lyme endemic area were included in the study (n = 146). Serum and CSF were collected on admission. Patients with other specific diagnoses were controls (n = 15). The recomBead Borrelia AI assay and the recomBead CXCL13 assay (Mikrogen) were applied together with total IgM index. The overall sensitivity for recomBead Borrelia AI (IgM and IgG together) was 74% and the specificity was 97%. However, the highest sensitivity (91%) at an acceptable level of specificity (90%) was obtained by recomBead Borrelia AI together with CXCL13 and total IgM index, showing a positive predictive value of 84% and a negative predictive value of 95%. Thus, the recomBead Borrelia AI assay performs with moderate sensitivity and high specificity in paediatric LNB patients. The major advantage seems to be increased sensitivity in the possible LNB group compared to the IDEIA assay. The diagnostic sensitivity may be further increased by using a combination of early markers, such as CXCL13 in CSF and total IgM index.

  7. Validation of an Immunodiagnostic Assay for Detection of 13 Streptococcus pneumoniae Serotype-Specific Polysaccharides in Human Urine

    PubMed Central

    Huijts, Susanne M.; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C.; Bonten, Marc J. M.; Jansen, Kathrin U.

    2012-01-01

    To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults. PMID:22675155

  8. Validation of an immunodiagnostic assay for detection of 13 Streptococcus pneumoniae serotype-specific polysaccharides in human urine.

    PubMed

    Pride, Michael W; Huijts, Susanne M; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C; Bonten, Marc J M; Jansen, Kathrin U

    2012-08-01

    To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults.

  9. Development and evaluation of a rapid recombinase polymerase amplification assay for detection of coxsackievirus A6.

    PubMed

    Wang, Kaifeng; Wu, Yue; Yin, Dan; Tang, Shixing; Hu, Guifang; He, Yaqing

    2017-01-01

    Coxsackievirus A6 (CV-A6) is an important pathogen causing hand, foot and mouth disease (HFMD). The aim of this study was to develop and evaluate a rapid real-time reverse transcription recombinase polymerase amplification (RT-RPA) assay for detection of CV-A6. The sensitivity of this assay was 202 copies/reaction, with 100 % specificity. Furthermore, this assay yielded consistent results comparable with a commercial qRT-PCR diagnostic kit. This assay is therefore potentially useful for surveillance of CV-A6 infections and outbreak control.

  10. Evaluation and improvement of real-time PCR assays targeting lytA, ply, and psaA genes for detection of pneumococcal DNA.

    PubMed

    Carvalho, Maria da Gloria S; Tondella, Maria Lucia; McCaustland, Karen; Weidlich, Luciana; McGee, Lesley; Mayer, Leonard W; Steigerwalt, Arnold; Whaley, Melissa; Facklam, Richard R; Fields, Barry; Carlone, George; Ades, Edwin W; Dagan, Ron; Sampson, Jacquelyn S

    2007-08-01

    The accurate diagnosis of pneumococcal disease has frequently been hampered not only by the difficulties in obtaining isolates of the organism from patient specimens but also by the misidentification of pneumococcus-like viridans group streptococci (P-LVS) as Streptococcus pneumoniae. This is especially critical when the specimen comes from the respiratory tract. In this study, three novel real-time PCR assays designed for the detection of specific sequence regions of the lytA, ply, and psaA genes were developed (lytA-CDC, ply-CDC, and psaA, respectively). These assays showed high sensitivity (<10 copies for lytA-CDC and ply-CDC and an approximately twofold less sensitivity for psaA). Two additional real-time PCR assays for lytA and ply described previously for pneumococcal DNA detection were also evaluated. A panel of isolates consisting of 67 S. pneumoniae isolates (44 different serotypes and 3 nonencapsulated S. pneumoniae isolates from conjunctivitis outbreaks) and 104 nonpneumococcal isolates was used. The 67 S. pneumoniae isolates were reactive in all five assays. The new real-time detection assays targeting the lytA and psaA genes were the most specific for the detection of isolates confirmed to be S. pneumoniae, with lytA-CDC showing the greatest specificity. Both ply PCRs were positive for all isolates of S. pseudopneumoniae, along with 13 other isolates of other P-LVS isolates confirmed to be non-S. pneumoniae by DNA-DNA reassociation. Thus, the use of the ply gene for the detection of pneumococci can lead to false-positive reactions in the presence of P-LVS. The five assays were applied to 15 culture-positive cerebrospinal fluid specimens with 100% sensitivity; and serum and ear fluid specimens were also evaluated. Both the lytA-CDC and psaA assays, particularly the lytA-CDC assay, have improved specificities compared with those of currently available assays and should therefore be considered the assays of choice for the detection of pneumococcal DNA, particularly when upper respiratory P-LVS might be present in the clinical specimen.

  11. Evaluation of phage assay for rapid phenotypic detection of rifampicin resistance in Mycobacterium tuberculosis

    PubMed Central

    Yzquierdo, Sergio Luis; Lemus, Dihadenys; Echemendia, Miguel; Montoro, Ernesto; McNerney, Ruth; Martin, Anandi; Palomino, Juan Carlos

    2006-01-01

    Background Conventional methods for susceptibility testing require several months before results can be reported. However, rapid methods to determine drug susceptibility have been developed recently. Phage assay have been reported as a rapid useful tools for antimicrobial susceptibility testing. The aim of this study was to apply the Phage assay for rapid detection of resistance on Mycobacterium tuberculosis strains in Cuba. Methods Phage D29 assay was performed on 102 M. tuberculosis strains to detect rifampicin resistance. The results were compared with the proportion method (gold standard) to evaluate the sensitivity and specificity of Phage assay. Results Phage assay results were available in 2 days whereas Proportion Methods results were obtain in 42 days. A total of 44 strains were detected as rifampicin resistant by both methods. However, one strains deemed resistant by Proportion Methods was susceptible by Phage assay. The sensitivity and specificity of Phage assay were 97.8 % and 100% respectively. Conclusion Phage assay provides rapid and reliable results for susceptibility testing; it's easy to perform, requires no specialized equipment and is applicable to drug susceptibility testing in low income countries where tuberculosis is a major public health problem. PMID:16630356

  12. Developing high throughput quantitative PCR assays for diagnosing Ikeda and other Theileria orientalis types common to New Zealand in bovine blood samples.

    PubMed

    Pulford, D J; Gias, E; Bueno, I M; McFadden, Amj

    2016-01-01

    To develop rapid, quantitative PCR (qPCR) assays using high resolution melt (HRM) analysis and type-specific TaqMan assays for identifying the prevalent types of Theileria orientalis found in New Zealand cattle; and to evaluate their analytical and diagnostic characteristics compared with other assays for T. orientalis. Nucleotide sequences aligned with T. orientalis Buffeli, Chitose and Ikeda types, obtained from DNA extracted from blood samples from infected cattle, were used to design HRM and type-specific probe-based qPCR assays. The three type-specific assays were also incorporated into a single-tube multiplex qPCR assay. These assays were validated using DNA extracted from blood samples from cattle in herds with or without clinical signs of T. orientalis infection, other veterinary laboratory samples, as well as plasmids containing T. orientalis type-specific sequences. Diagnostic specificity (DSp) and sensitivity (DSe) estimates for the qPCR assays were compared to blood smear piroplasm results, and other PCR assays for T. orientalis. Copy number estimates of Ikeda DNA in blood were determined from cattle exhibiting anaemia using the Ikeda-specific qPCR assay. The T. orientalis type-specific and the HRM qPCR assays displayed 100% analytical specificity. The Ikeda-specific qPCR assay exhibited linearity (R(2) = 0.997) with an efficiency of 94.3%. Intra-assay CV were ≤0.08 and inter-assay CV were ≤0.095. For blood samples from cows with signs of infection with T. orientalis, the DSp and DSe of the multiplex probe qPCR assay were 93 and 96%, respectively compared with blood smears, and 97 and 100%, respectively compared with conventional PCR assays. For the Ikeda-specific qPCR assay, the number of positive samples (n=66) was slightly higher than a conventional PCR assay (n=64). The concentration of Ikeda genomes in blood samples from 41 dairy cows with signs of infection with T. orientalis ranged between 5.6 × 10(4) and 3.3 × 10(6) genomes per µL of blood. All qPCR assays had improved specificity and sensitivity over existing conventional PCR assays for diagnosis of T. orientalis Ikeda. The burden of Ikeda DNA in blood was demonstrated using an Ikeda-specific qPCR assay with titrated synthetic gene target. Adoption of high-throughput DNA extraction and qPCR reduced T. orientalis and Ikeda diagnosis times. The Ikeda-specific qPCR assay provides a specific diagnosis for Ikeda in animals with signs of infection with T. orientalis and can be used to monitor the parasite load of Ikeda in blood.

  13. Cross-reactions in specific Brachyspira spp. PCR assays caused by "Brachyspira hampsonii" isolates: implications for detection.

    PubMed

    Aller-Morán, Luis M; Martínez-Lobo, F Javier; Rubio, Pedro; Carvajal, Ana

    2016-11-01

    An emerging novel spirochete in swine, provisionally designated "Brachyspira hampsonii," has been detected worldwide. It has been associated with swine dysentery and cannot be differentiated from B. hyodysenteriae, the classical etiologic agent of this disease, using standard phenotypic methods. We evaluated cross-reactions of "B. hampsonii" isolates recovered from avian species in some of the currently available species-specific polymerase chain reaction (PCR) assays for the identification of swine Brachyspira species. Ten avian "B. hampsonii" isolates recovered from wild waterfowl were used. No false-positive results were recorded with a B. pilosicoli-specific PCR based on the amplification of a fragment of the 16S rRNA gene. However, the percentage of false-positive results varied, with a range of 10-80%, in the evaluated B. hyodysenteriae-specific assays based on the amplification of the 23S rRNA, nox, and tlyA genes. Similarly, results of the B. intermedia-specific PCR assays yielded poor specificity, with up to 80% of the "B. hampsonii" isolates tested giving false-positive results. Finally, 2 "B. hampsonii" avian isolates yielded a positive result in a B. innocens- and B. murdochii-specific PCR. This result should be interpreted very cautiously as these 2 isolates could represent a recombinant genotype. © 2016 The Author(s).

  14. Evaluation of the Abbott ARCHITECT Toxo IgM assay.

    PubMed

    Sickinger, Eva; Braun, Hans-Bertram; Praast, Gerald; Stieler, Myriam; Gundlach, Cordelia; Birkenbach, Claudia; Prostko, John; Palafox, Mary Ann; Frias, Edwin; Hsu, Stephen; Matias, Matthew; Pucci, Dominick; Hausmann, Michael; Sagel, Ulrich; Smith, Darwin

    2009-07-01

    Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays.

  15. The use of ex vivo human skin tissue for genotoxicity testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reus, Astrid A.; Usta, Mustafa; Krul, Cyrille A.M., E-mail: cyrille.krul@tno.nl

    2012-06-01

    As a result of the chemical legislation concerning the registration, evaluation, authorization and restriction of chemicals (REACH), and the Seventh Amendment to the Cosmetics Directive, which prohibits animal testing in Europe for cosmetics, alternative methods for safety evaluation of chemicals are urgently needed. Current in vitro genotoxicity assays are not sufficiently predictive for the in vivo situation, resulting in an unacceptably high number of misleading positives. For many chemicals and ingredients of personal care products the skin is the first site of contact, but there are no in vitro genotoxicity assays available in the skin for additional evaluation of positivemore » or equivocal responses observed in regulatory in vitro genotoxicity assays. In the present study ex vivo human skin tissue obtained from surgery was used for genotoxicity evaluation of chemicals by using the comet assay. Fresh ex vivo human skin tissue was cultured in an air–liquid interface and topically exposed to 20 chemicals, including true positive, misleading positive and true negative genotoxins. Based on the results obtained in the present study, the sensitivity, specificity and accuracy of the ex vivo skin comet assay to predict in vivo genotoxicity were 89%, 90% and 89%, respectively. Donor and experimental variability were mainly reflected in the magnitude of the response and not the difference between the presence and absence of a genotoxic response. The present study indicates that human skin obtained from surgery is a promising and robust model for safety evaluation of chemicals that are in direct contact with the skin. -- Highlights: ► We use human skin obtained from surgery for genotoxicity evaluation of chemicals. ► We use the comet assay as parameter for genotoxicity in ex vivo human skin. ► Sensitivity, specificity and accuracy to predict in vivo genotoxins are determined. ► Sensitivity, specificity and accuracy are 89%, 90% and 90%, respectively. ► The method is suitable for evaluation of chemicals that are in contact with skin.« less

  16. An evaluation of the automated assay of urinary oestrogens in pregnant women

    PubMed Central

    Muir, G. G.; Ryan, M.; Conaill, D. U.

    1970-01-01

    An automated assay suitable for estimating urinary oestrogens in pregnant women has been investigated. Fluorimetry was found to have considerable advantages over colorimetry. The fluorimetric assay was simpler, more precise, more sensitive, and eliminated the need for correction for non-specific chromogens; in the assay of oestriol in pregnant women there was no need for correction for non-specific fluorescence. Spectrofluorimetric and photometric analyses, recoveries, and reproducibility show that the method offers a robust means of providing values for urinary oestrogen in pregnant women on a scale of up to 100 tests a day, the time of the assay being one and a half hours. PMID:5476876

  17. Comparison of the Third Wave Invader Human Papillomavirus (HPV) Assay and the Digene HPV Hybrid Capture 2 Assay for Detection of High-Risk HPV DNA▿

    PubMed Central

    Ginocchio, C. C.; Barth, D.; Zhang, F.

    2008-01-01

    This study compared the clinical performance of the Digene Hybrid Capture 2 (HC2) assay to that of a prototype Third Wave Invader human papillomavirus (HPV) (IHPV) analyte-specific reagent-based assay for the detection of oncogenic or “high-risk” (HR) HPV DNA using liquid-based cytology specimens. In total, 821 ThinPrep vials were tested using both assays. In accordance with the type-specific probes contained within each test, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the IHPV assay were 95.9%, 97.6%, 97.5%, and 96.1%, respectively, and those for the HC2 assay were 98.1%, 86.2%, 87.1%, and 97.9%. Overall, the sensitivity and NPV were comparable between the assays, but the IHPV assay demonstrated a better specificity and PPV, since the IHPV assay had fewer false-positive HR HPV results. The incorporation of an internal control to evaluate the cellularity of the test material is an important feature of the IHPV assay and should reduce the risk of false-negative results due to insufficient sample collection rather than the lack of HR HPV DNA. An additional benefit of the IHPV assay was the smaller sample volume required (1 ml versus 4 ml for the HC2 assay). PMID:18367578

  18. Specific, sensitive, and rapid assay for human immunodeficiency virus type 1 pol mutations associated with resistance to zidovudine and didanosine.

    PubMed Central

    Frenkel, L M; Wagner, L E; Atwood, S M; Cummins, T J; Dewhurst, S

    1995-01-01

    The effectiveness of antiretroviral therapy may be limited by the development of human immunodeficiency virus type 1 (HIV-1) resistance. Monitoring for resistance will perhaps allow changes in therapy prior to deterioration in the patient's clinical or immunologic status. Our objective was to develop a rapid, specific, and sensitive genotypic assay for HIV-1 resistance to zidovudine (ZDV) and didanosine (ddI) which is simple to perform. In our assay the DNA of HIV-1 pol was amplified by PCR using two sets of nested oligonucleotide primers. Mutations of reverse transcriptase (RT) encoding amino acids (aa) 74 and 41, 70, and 215 which have been associated with HIV-1 resistance to ddI and ZDV, respectively, were detected with a ligase detection reaction (LDR) and indicated colorimetrically. The RT genotypes of 35 patient specimens (140 codons) blindly assessed for these mutations were in agreement by PCR-LDR and by dideoxynucleotide sequencing. To evaluate the limits of the assay, other specimens with mutations close to the ligation site were evaluated by PCR-LDR. The assay was sensitive and specific for all specimens except when mutations occurred within 2 bases on either side of the ligation site. In summary, this PCR-LDR assay specifically, sensitively, and rapidly detected pol mutations (RT aa 74, 41, 70, and 215) associated with HIV-1 resistance to ddI and ZDV. PMID:7714190

  19. Evaluation of a real-time PCR assay based on the single-copy SAG1 gene for the detection of Toxoplasma gondii.

    PubMed

    Yu, Haijie; Huang, Bin; Zhuo, Xunhui; Chen, Xueqiu; Du, Aifang

    2013-11-08

    Real-time PCR-based detection of Toxoplasma gondii is very sensitive and convenient for diagnosing toxoplasmosis. However, the performance of the PCR assays could be influenced by the target gene chosen. Here we evaluate a real-time PCR assay using double-stranded DNA dyes (SYBR(®) Green I assay) with a new set of primers targeting the SAG1 gene for the fast and specific detection of T. gondii. The assay showed higher sensitivity than conventional PCR protocols using T. gondii DNA as template. The detection limit of the developed real-time PCR assay was in the order of 1 tachyzoite. The assay was also assessed by experimentally infected mice and showed positive results for blood (25%), spleen (50%) and lung (50%) as early as 1 dpi. The specificity of the assay was confirmed by using DNA from Neospora caninum, Escherichia coli, Babesia bovis, Trypanosoma brucei, Cryptosporidium parvum, and Toxocara canis. Assay applicability was successfully tested in blood samples collected from slaughtered pigs. These results indicate that, based on SYBR(®) green I, the quantitative SAG1 assay may also be useful in the study of the pathogenicity, immunoprophylaxis, and treatment of T. gondii. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Multiplex real-time PCR assay for detection of pathogenic Vibrio parahaemolyticus strains.

    PubMed

    He, Peiyan; Chen, Zhongwen; Luo, Jianyong; Wang, Henghui; Yan, Yong; Chen, Lixia; Gao, Wenjie

    2014-01-01

    Foodborne disease caused by pathogenic Vibrio parahaemolyticus has become a serious public health problem in many countries. Rapid diagnosis and the identification of pathogenic V. parahaemolyticus are very important in the context of public health. In this study, an EvaGreen-based multiplex real-time PCR assay was established for the detection of pathogenic V. parahaemolyticus. This assay targeted three genetic markers of V. parahaemolyticus (species-specific gene toxR and virulence genes tdh and trh). The assay could unambiguously identify pathogenic V. parahaemolyticus with a minimum detection limit of 1.4 pg genomic DNA per reaction (concentration giving a positive multiplex real-time PCR result in 95% of samples). The specificity of the assay was evaluated using 72 strains of V. parahaemolyticus and other bacteria. A validation of the assay with clinical samples confirmed its sensitivity and specificity. Our data suggest the newly established multiplex real-time PCR assay is practical, cost-effective, specific, sensitive and capable of high-throughput detection of pathogenic V. parahaemolyticus. Copyright © 2014. Published by Elsevier Ltd.

  1. Reduced-cost Chlamydia trachomatis-specific multiplex real-time PCR diagnostic assay evaluated for ocular swabs and use by trachoma research programmes.

    PubMed

    Butcher, Robert; Houghton, Jo; Derrick, Tamsyn; Ramadhani, Athumani; Herrera, Beatriz; Last, Anna R; Massae, Patrick A; Burton, Matthew J; Holland, Martin J; Roberts, Chrissy H

    2017-08-01

    Trachoma, caused by the intracellular bacterium Chlamydia trachomatis (Ct), is the leading infectious cause of preventable blindness. Many commercial platforms are available that provide highly sensitive and specific detection of Ct DNA. However, the majority of these commercial platforms are inaccessible for population-level surveys in resource-limited settings typical to trachoma control programmes. We developed two low-cost quantitative PCR (qPCR) tests for Ct using readily available reagents on standard real-time thermocyclers. Each multiplex qPCR test targets one genomic and one plasmid Ct target in addition to an endogenous positive control for Homo sapiens DNA. The quantitative performance of the qPCR assays in clinical samples was determined by comparison to a previously evaluated droplet digital PCR (ddPCR) test. The diagnostic performance of the qPCR assays were evaluated against a commercial assay (artus C. trachomatis Plus RG PCR, Qiagen) using molecular diagnostics quality control standards and clinical samples. We examined the yield of Ct DNA prepared from five different DNA extraction kits and a cold chain-free dry-sample preservation method using swabs spiked with fixed concentrations of human and Ct DNA. The qPCR assay was highly reproducible (Ct plasmid and genomic targets mean total coefficients of variance 41.5% and 48.3%, respectively). The assay detected 8/8 core specimens upon testing of a quality control panel and performed well in comparison to commercially marketed comparator test (sensitivity and specificity>90%). Optimal extraction and sample preservation methods for research applications were identified. We describe a pipeline from collection to diagnosis providing the most efficient sample preservation and extraction with significant per test cost savings over a commercial qPCR diagnostic assay. The assay and its evaluation should allow control programs wishing to conduct independent research within the context of trachoma control, access to an affordable test with defined performance characteristics. Copyright © 2017. Published by Elsevier B.V.

  2. Enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence.

    PubMed Central

    Crouch, C F

    1995-01-01

    AIMS--To evaluate the clinical performance of enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence. METHODS--Classification of routine clinical samples from the originating laboratories was compared with that obtained using the chemiluminescence based assays. Resolution of discordant results was achieved by testing in alternative enzyme immunoassays (IgM) or by an independent laboratory using the dye test (IgG). RESULTS--Compared with resolved data, the IgM assay was found to be highly specific (100%) with a cut off selected to give optimal performance with respect to both the early detection of specific IgM and the detection of persistent levels of specific IgM (sensitivity 98%). Compared with resolved data, the IgG assay was shown to have a sensitivity and a specificity of 99.4%. CONCLUSIONS--The Amerlite Toxo IgM assay possesses high levels of sensitivity and specificity. Assay interference due to rheumatoid factor like substances is not a problem. The Amerlite Toxo IgG assay possesses good sensitivity and specificity, but is less sensitive for the detection of seroconversion than methods detecting both IgG and IgM. PMID:7560174

  3. Performance Evaluation of the Elecsys Syphilis Assay for the Detection of Total Antibodies to Treponema pallidum

    PubMed Central

    Enders, Martin; Hunjet, Andrea; Gleich, Michael; Imdahl, Roland; Mühlbacher, Annelies; Schennach, Harald; Chaiwong, Kriangsak; Sakuldamrongpanich, Tasanee; Turhan, Ajda; Sertöz, Rüchan; Wolf, Eva; Mayer, Wolfgang; Tao, Chuanmin; Wang, Lan Lan; Semprini, Simona

    2014-01-01

    Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified. PMID:25355799

  4. Evaluation of Elecsys Syphilis Assay for Routine and Blood Screening and Detection of Early Infection

    PubMed Central

    Kremastinou, J.; Polymerou, V.; Lavranos, D.; Aranda Arrufat, A.; Harwood, J.; Martínez Lorenzo, M. J.; Ng, K. P.; Queiros, L.; Vereb, I.

    2016-01-01

    Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum. The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. PMID:27358468

  5. A novel method for evaluating antibody-dependent cell-mediated cytotoxicity by flowcytometry using cryopreserved human peripheral blood mononuclear cells

    PubMed Central

    Yamashita, Makiko; Kitano, Shigehisa; Aikawa, Hiroaki; Kuchiba, Aya; Hayashi, Mitsuhiro; Yamamoto, Noboru; Tamura, Kenji; Hamada, Akinobu

    2016-01-01

    Analyzing the cytotoxic functions of effector cells, such as NK cells against target cancer cells, is thought to be necessary for predicting the clinical efficacy of antibody-dependent cellular cytotoxicity (ADCC) -dependent antibody therapy. The 51Cr release assay has long been the most widely used method for quantification of ADCC activity. However, the reproducibilities of these release assays are not adequate, and they do not allow evaluation of the lysis susceptibilities of distinct cell types within the target cell population. In this study, we established a novel method for evaluating cytotoxicity, which involves the detection and quantification of dead target cells using flowcytometry. CFSE (carboxyfluorescein succinimidyl ester) was used as a dye to specifically stain and thereby label the target cell population, allowing living and dead cells, as well as both target and effector cells, to be quantitatively distinguished. Furthermore, with our new approach, ADCC activity was more reproducibly, sensitively, and specifically detectable, not only in freshly isolated but also in frozen human peripheral blood mononuclear cells (PBMCs), than with the calcein-AM release assay. This assay, validated herein, is expected to become a standard assay for evaluating ADCC activity which will ultimately contribute the clinical development of ADCC dependent-antibody therapies. PMID:26813960

  6. A novel method for evaluating antibody-dependent cell-mediated cytotoxicity by flowcytometry using cryopreserved human peripheral blood mononuclear cells.

    PubMed

    Yamashita, Makiko; Kitano, Shigehisa; Aikawa, Hiroaki; Kuchiba, Aya; Hayashi, Mitsuhiro; Yamamoto, Noboru; Tamura, Kenji; Hamada, Akinobu

    2016-01-27

    Analyzing the cytotoxic functions of effector cells, such as NK cells against target cancer cells, is thought to be necessary for predicting the clinical efficacy of antibody-dependent cellular cytotoxicity (ADCC) -dependent antibody therapy. The (51)Cr release assay has long been the most widely used method for quantification of ADCC activity. However, the reproducibilities of these release assays are not adequate, and they do not allow evaluation of the lysis susceptibilities of distinct cell types within the target cell population. In this study, we established a novel method for evaluating cytotoxicity, which involves the detection and quantification of dead target cells using flowcytometry. CFSE (carboxyfluorescein succinimidyl ester) was used as a dye to specifically stain and thereby label the target cell population, allowing living and dead cells, as well as both target and effector cells, to be quantitatively distinguished. Furthermore, with our new approach, ADCC activity was more reproducibly, sensitively, and specifically detectable, not only in freshly isolated but also in frozen human peripheral blood mononuclear cells (PBMCs), than with the calcein-AM release assay. This assay, validated herein, is expected to become a standard assay for evaluating ADCC activity which will ultimately contribute the clinical development of ADCC dependent-antibody therapies.

  7. European Multicenter Study on Analytical Performance of DxN Veris System HCV Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Gismondo, Maria Rita; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Marcos, Maria Angeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-04-01

    The analytical performance of the Veris HCV Assay for use on the new and fully automated Beckman Coulter DxN Veris Molecular Diagnostics System (DxN Veris System) was evaluated at 10 European virology laboratories. Precision, analytical sensitivity, specificity, and performance with negative samples, linearity, and performance with hepatitis C virus (HCV) genotypes were evaluated. Precision for all sites showed a standard deviation (SD) of 0.22 log 10 IU/ml or lower for each level tested. Analytical sensitivity determined by probit analysis was between 6.2 and 9.0 IU/ml. Specificity on 94 unique patient samples was 100%, and performance with 1,089 negative samples demonstrated 100% not-detected results. Linearity using patient samples was shown from 1.34 to 6.94 log 10 IU/ml. The assay demonstrated linearity upon dilution with all HCV genotypes. The Veris HCV Assay demonstrated an analytical performance comparable to that of currently marketed HCV assays when tested across multiple European sites. Copyright © 2017 American Society for Microbiology.

  8. Synthesis and evaluation of fluorogenic triglycerides as lipase assay substrates.

    PubMed

    Andersen, Rokhsana J; Brask, Jesper

    2016-06-01

    Three racemic fluorogenic triglycerides are synthesized and evaluated as lipase assay substrates. The presented synthesis route goes through a key triglyceride intermediate which can be chemoselectively functionalized with a wide range of different probes. Hence the substrate can be tailor-made for a specific assay, or focus can be on low cost in larger scale for applications in high-throughput screening (HTS) assays. In the specific examples, TG-ED, TG-FD and TG-F2 are assembled with the Edans-Dabcyl or the fluorescein-Dabcyl FRET pair, or relying on fluorescein self-quenching, respectively. Proof-of-concept assays allowed determination of 1st order kinetic parameters (kcat/KM) of 460s(-1)M(-1), 59s(-1)M(-1) and 346s(-1)M(-1), respectively, for the three substrates. Commercially available EnzChek lipase substrate provided 204s(-1)M(-1). Substrate concentration was identified as a critical parameter, with measured reaction rates decreasing at higher concentrations when intermolecular quenching becomes significant. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Evaluation of ethanol vortex ELISA for detection of bovine tuberculosis in cattle and deer

    USDA-ARS?s Scientific Manuscript database

    Background The use of serological assays for diagnosis of bovine tuberculosis (TB) has been intensively studied and use of specific antigens have aided in improving the diagnostic accuracy of the assays. In the present study, we report an in-house enzyme linked immunosorbent assay (ELISA), developed...

  10. Clinical and diagnostic developments of a gamma interferon release assay for use in bovine tuberculosis control programs

    USDA-ARS?s Scientific Manuscript database

    Currently the Bovigam assay is used as an official supplemental test within the bovine tuberculosis eradication program. This assay measures interferon-gamma (IFN-gamma) produced by lymphocytes in response to specific antigens. The objectives of the present study were to evaluate two Mycobacterium ...

  11. Urine sample used for detection of toxoplasma gondii infection by loop-mediated isothermal amplification (LAMP).

    PubMed

    Hu, Xin; Pan, Chang-Wang; Li, Ya-Fei; Wang, Han; Tan, Feng

    2012-02-01

    In this study, a loop-mediated isothermal amplification (LAMP) assay was established to detect Toxoplasma gondii DNA in mice infected with T. gondii PRU strain. This LAMP assay was based on the sequence of highly repetitive B1 gene. The detection limit of T. gondii LAMP assay was 1 pg of T. gondii DNA, which was evaluated using 10-fold serially diluted DNA of cultured parasites. The LAMP assay was also highly specific for T. gondii and able to detect T. gondii DNA in urine of mice treated with dexamethasone at 90 day post infection (p.i.), although this assay could not detect the DNA in mice urine 2-6 days p.i. These results demonstrated that LAMP is effective for evaluation of therapy effectiveness for T. gondii infection. The established LAMP assay may represent a useful and practical tool for the routine diagnosis and therapeutic evaluation of human toxoplasmosis.

  12. Evaluation of the new AmpliSens multiplex real-time PCR assay for simultaneous detection of Neisseria gonorrhoeae, Chlamydia trachomatis, Mycoplasma genitalium, and Trichomonas vaginalis.

    PubMed

    Rumyantseva, Tatiana; Golparian, Daniel; Nilsson, Christian S; Johansson, Emma; Falk, My; Fredlund, Hans; Van Dam, Alje; Guschin, Alexander; Unemo, Magnus

    2015-10-01

    In this study, we performed an evaluation of the new CE-marked multiplex real-time AmpliSens N.gonorrhoeae/C.trachomatis/M.genitalium/T.vaginalis-MULTIPRIME-FRT PCR assay compared to APTIMA tests, i.e., APTIMA COMBO 2 assay, APTIMA Trichomonas vaginalis assay (FDA-approved), and two different APTIMA Mycoplasma genitalium assays (research use only; one of them only used for discrepancy analysis). Vaginal swabs (n = 209) and first-void urine (FVU) specimens from females (n = 498) and males (n = 554), consecutive attendees (n = 1261) at a dermatovenerological clinic in Sweden, were examined. The sensitivity of the AmpliSens PCR assay for detection of C. trachomatis (6.3% prevalence), M. genitalium (5.7% prevalence), N. gonorrhoeae (0.3% prevalence), and T. vaginalis (0.08% prevalence) was 97.5% (95% confidence interval (CI): 91.2-99.6%), 81.9% (95% CI: 70.7-89.7%), 100% (95% CI: 40.2-100%) and 100% (95% CI: 16.5-100%), respectively. The specificity of the AmpliSens PCR assay was 100% (95% CI: 99.6-100%) for all agents. The analytical sensitivity and specificity for N. gonorrhoeae detection was excellent, i.e., 55 international gonococcal strains detected and 135 isolates of 13 non-gonococcal Neisseria species were negative. In conclusion, the multiplex real-time AmpliSens N.gonorrhoeae/C.trachomatis/M.genitalium/T.vaginalis-MULTIPRIME-FRT PCR assay demonstrated high sensitivity and excellent specificity for the detection of C. trachomatis, N. gonorrhoeae, and T. vaginalis, and excellent specificity but suboptimal sensitivity for M. genitalium detection. © 2015 APMIS. Published by John Wiley & Sons Ltd.

  13. Sensitivity and specificity of the circulating cathodic antigen rapid urine test in the diagnosis of Schistosomiasis mansoni infection and evaluation of morbidity in a low- endemic area in Brazil.

    PubMed

    Ferreira, Fernanda Teixeira; Fidelis, Thiago André; Pereira, Thiago Almeida; Otoni, Alba; Queiroz, Leonardo Campos; Amâncio, Frederico Figueiredo; Antunes, Carlos Maurício; Lambertucci, José Roberto

    2017-01-01

    The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. However, the utility of this method is severely limited by the day-to-day variability in host egg excretion in the stool. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. However, investigations of the reliability of the POC-CCA assay in low-transmission regions are under way. This study aimed to evaluate the sensitivity and specificity of the POC-CCA assay and the morbidity of schistosomiasis in a low-endemic area in Brazil. Pains City is a low-transmission zone for schistosomiasis. A total of 300 subjects aged 7-76 years were randomly selected for the POC-CCA cassette test. For S. mansoni diagnosis, three stool samples on six slides were compared with one urine sample for each subject. The sensitivity and specificity in the absence of a gold standard were calculated using latent class analysis. Clinical examinations and abdominal ultrasounds were performed in 181 volunteers to evaluate morbidity associated with schistosomiasis. The sensitivity and specificity of the Kato-Katz technique were 25.6% and 94.6%, respectively. By contrast, the sensitivity and specificity of the POC-CCA assay were 68.1% and 72.8%, respectively. Hepatosplenic schistosomiasis was diagnosed in two patients (1.1%). Overall, the POC-CCA urine assay proved to be a useful test for diagnosing S. mansoni in a low-endemic area in Brazil. Severe clinical forms of schistosomiasis can be present even in such low-endemic areas.

  14. Loop-mediated isothermal amplification assay for detection of Haemophilus influenzae type b in cerebrospinal fluid.

    PubMed

    Kim, Dong Wook; Kilgore, Paul Evan; Kim, Eun Jin; Kim, Soon Ae; Anh, Dang Duc; Seki, Mitsuko

    2011-10-01

    Haemophilus influenzae type b (Hib) is one of the leading causes of meningitis in developing countries. To establish and evaluate a novel loop-mediated isothermal amplification (LAMP) assay for Hib, we designed a LAMP primer set targeting the Hib-specific capsulation locus. LAMP detected 10 copies of purified DNA in a 60-min reaction. This indicated that the detection limit of LAMP was >100-fold lower than the detection limits of both a PCR for the detection of bexA and a nested PCR for Hib (Hib PCR). No H. influenzae, other than Hib or control bacteria, was detected. Linear determination ranged from 10 to 1,000,000 microorganisms per reaction mixture using real-time turbidimetry. We evaluated the Hib LAMP assay using a set of 52 randomly selected cerebrospinal fluid (CSF) specimens obtained from children with suspected meningitis. For comparison, the CSF specimens were tested using a conventional Hib PCR assay. Hib was detected in 30 samples using LAMP and in 22 samples using the Hib PCR assay. The Hib PCR showed a clinical sensitivity of 73.3% and a clinical specificity of 100% relative to the Hib LAMP assay. These results suggest that further development and evaluation of the Hib LAMP will enhance the global diagnostic capability for Hib detection.

  15. Nanoparticle-assay marker interaction: effects on nanotoxicity assessment

    NASA Astrophysics Data System (ADS)

    Zhao, Xinxin; Xiong, Sijing; Huang, Liwen Charlotte; Ng, Kee Woei; Loo, Say Chye Joachim

    2015-01-01

    Protein-based cytotoxicity assays such as lactate dehydrogenase (LDH) and tumor necrosis factor-alpha (TNF-α) are commonly used in cytotoxic evaluation of nanoparticles (NPs) despite numerous reports on possible interactions with protein markers in these assays that can confound the results obtained. In this study, conventional cytotoxicity assays where assay markers may (LDH and TNF- α) or may not (PicoGreen and WST-8) come into contact with NPs were used to evaluate the cytotoxicity of NPs. The findings revealed selective interactions between negatively charged protein assay markers (LDH and TNF- α) and positively charged ZnO NPs under abiotic conditions. The adsorption and interaction with these protein assay markers were strongly influenced by surface charge, concentration, and specific surface area of the NPs, thereby resulting in less than accurate cytotoxic measurements, as observed from actual cell viability measurements. An improved protocol for LDH assay was, therefore, proposed and validated by eliminating any effects associated with protein-particle interactions. In view of this, additional measures and precautions should be taken when evaluating cytotoxicity of NPs with standard protein-based assays, particularly when they are of opposite charges.

  16. Comprehensive GMO detection using real-time PCR array: single-laboratory validation.

    PubMed

    Mano, Junichi; Harada, Mioko; Takabatake, Reona; Furui, Satoshi; Kitta, Kazumi; Nakamura, Kosuke; Akiyama, Hiroshi; Teshima, Reiko; Noritake, Hiromichi; Hatano, Shuko; Futo, Satoshi; Minegishi, Yasutaka; Iizuka, Tayoshi

    2012-01-01

    We have developed a real-time PCR array method to comprehensively detect genetically modified (GM) organisms. In the method, genomic DNA extracted from an agricultural product is analyzed using various qualitative real-time PCR assays on a 96-well PCR plate, targeting for individual GM events, recombinant DNA (r-DNA) segments, taxon-specific DNAs, and donor organisms of the respective r-DNAs. In this article, we report the single-laboratory validation of both DNA extraction methods and component PCR assays constituting the real-time PCR array. We selected some DNA extraction methods for specified plant matrixes, i.e., maize flour, soybean flour, and ground canola seeds, then evaluated the DNA quantity, DNA fragmentation, and PCR inhibition of the resultant DNA extracts. For the component PCR assays, we evaluated the specificity and LOD. All DNA extraction methods and component PCR assays satisfied the criteria set on the basis of previous reports.

  17. Evaluation of the usefulness of six commercial agglutination assays for serologic diagnosis of toxoplasmosis.

    PubMed

    Villard, Odile; Cimon, Bernard; Franck, Jacqueline; Fricker-Hidalgo, Hélène; Godineau, Nadine; Houze, Sandrine; Paris, Luc; Pelloux, Hervé; Villena, Isabelle; Candolfi, Ermanno

    2012-07-01

    Six agglutination tests for detecting Toxoplasma gondii-specific antibodies (immunoglobulin G or M) in serum were performed and compared. In total, 599 sera were examined using direct and indirect agglutination assays. Sensitivity varied from 93.7% to 100% and specificity from 97.1% to 99.2%. In a selected population with interfering diseases, the percentage of false positives ranged from 4.3% to 10.9%. Although an overall agreement of 100% was found for chronic toxoplasmosis, sensitivity for the detection of confirmed acute toxoplasmosis ranged from 86.4% to 97.3%. Regarding the large variability in terms of the performance of the 6 assays, tests based on the hemagglutination principle were found to be better than the other agglutination tests for all the panels evaluated, meaning that they could be used as qualitative or semiquantitative low-cost screening assays. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. A real-time polymerase chain reaction assay for the detection of Mycoplasma agalactiae.

    PubMed

    Fitzmaurice, J; Sewell, M; King, C M; McDougall, S; McDonald, W L; O'Keefe, J S

    2008-10-01

    To develop a real-time PCR for the detection of Mycoplasma agalactiae, using PCR primers targeting the ma-mp81 gene. A group of 15 M. agalactiae isolates, 21 other Mycoplasma spp. isolates and 21 other bacterial isolates was used in evaluation of the assay. All M. agalactiae isolates were detected by the assay and none of the non-target isolates was amplified. The analytical detection limit of the assay was 10 fg of purified genomic DNA and 104 cfu/ml milk inoculated with M. agalactiae. When applied to goat-milk samples collected from three herds free of M. agalactiae infection, the assay had a specificity of 100%. The assay would be useful in a diagnostic laboratory, providing specific, sensitive and rapid detection of M. agalactiae.

  19. An Evaluation Study of Enzyme-Linked Immunosorbent Assay (ELISA) Using Recombinant Protein Pap31 for Detection of Antibody against Bartonella bacilliformis Infection among the Peruvian Population

    PubMed Central

    Angkasekwinai, Nasikarn; Atkins, Erin H.; Romero, Sofia; Grieco, John; Chao, Chien Chung; Ching, Wei Mei

    2014-01-01

    Reliable laboratory testing is of great importance to detect Bartonella bacilliformis infection. We evaluated the sensitivity and specificity of the enzyme-linked immunosorbent assay (ELISA) using recombinant protein Pap31 (rPap31) for the detection of antibodies against B. bacilliformis as compared with immunofluorescent assay (IFA). Of the 302 sera collected between 1997 and 2000 among an at-risk Peruvian population, 103 and 34 samples tested positive for IFA-immunoglobulin G (IgG) and IFA-IgM, respectively. By using Youden's index, the cutoff values of ELISA-IgG at 0.915 gave a sensitivity of 84.5% and specificity of 94%. The cutoff values of ELISA-IgM at 0.634 gave a sensitivity of 88.2% and specificity of 85.1%. Using latent class analysis, estimates of sensitivity and specificity of almost all the assays were slightly higher than those of a conventional method of calculation. The test is proved beneficial for discriminating between infected and non-infected individuals with the advantage of low-cost and high-throughput capability. PMID:24515944

  20. Simultaneous point-of-care detection of anemia and sickle cell disease in Tanzania: the RAPID study.

    PubMed

    Smart, Luke R; Ambrose, Emmanuela E; Raphael, Kevin C; Hokororo, Adolfine; Kamugisha, Erasmus; Tyburski, Erika A; Lam, Wilbur A; Ware, Russell E; McGann, Patrick T

    2018-02-01

    Both anemia and sickle cell disease (SCD) are highly prevalent across sub-Saharan Africa, and limited resources exist to diagnose these conditions quickly and accurately. The development of simple, inexpensive, and accurate point-of-care (POC) assays represents an important advance for global hematology, one that could facilitate timely and life-saving medical interventions. In this prospective study, Robust Assays for Point-of-care Identification of Disease (RAPID), we simultaneously evaluated a POC immunoassay (Sickle SCAN™) to diagnose SCD and a first-generation POC color-based assay to detect anemia. Performed at Bugando Medical Center in Mwanza, Tanzania, RAPID tested 752 participants (age 1 day to 20 years) in four busy clinical locations. With minimally trained medical staff, the SCD POC assay diagnosed SCD with 98.1% sensitivity and 91.1% specificity. The hemoglobin POC assay had 83.2% sensitivity and 74.5% specificity for detection of severe anemia (Hb ≤ 7 g/dL). Interobserver agreement was excellent for both POC assays (r = 0.95-0.96). Results for the hemoglobin POC assay have informed the second-generation assay design to be more suitable for low-resource settings. RAPID provides practical feasibility data regarding two novel POC assays for the diagnosis of anemia and SCD in real-world field evaluations and documents the utility and potential impact of these POC assays for sub-Saharan Africa.

  1. The Applicability of TaqMan-Based Quantitative Real-Time PCR Assays for Detecting and Enumerating Cryptosporidium spp. Oocysts in the Environment

    PubMed Central

    Staggs, Sarah E.; Beckman, Erin M.; Keely, Scott P.; Mackwan, Reena; Ware, Michael W.; Moyer, Alan P.; Ferretti, James A.; Sayed, Abu; Xiao, Lihua; Villegas, Eric N.

    2013-01-01

    Quantitative real-time polymerase chain reaction (qPCR) assays to detect Cryptosporidium oocysts in clinical samples are increasingly being used to diagnose human cryptosporidiosis, but a parallel approach for detecting and identifying Cryptosporidium oocyst contamination in surface water sources has yet to be established for current drinking water quality monitoring practices. It has been proposed that Cryptosporidium qPCR-based assays could be used as viable alternatives to current microscopic-based detection methods to quantify levels of oocysts in drinking water sources; however, data on specificity, analytical sensitivity, and the ability to accurately quantify low levels of oocysts are limited. The purpose of this study was to provide a comprehensive evaluation of TaqMan-based qPCR assays, which were developed for either clinical or environmental investigations, for detecting Cryptosporidium oocyst contamination in water. Ten different qPCR assays, six previously published and four developed in this study were analyzed for specificity and analytical sensitivity. Specificity varied between all ten assays, and in one particular assay, which targeted the Cryptosporidium 18S rRNA gene, successfully detected all Cryptosporidium spp. tested, but also cross-amplified T. gondii, fungi, algae, and dinoflagellates. When evaluating the analytical sensitivity of these qPCR assays, results showed that eight of the assays could reliably detect ten flow-sorted oocysts in reagent water or environmental matrix. This study revealed that while a qPCR-based detection assay can be useful for detecting and differentiating different Cryptosporidium species in environmental samples, it cannot accurately measure low levels of oocysts that are typically found in drinking water sources. PMID:23805235

  2. Use of the Abbott Architect HIV antigen/antibody assay in a low incidence population.

    PubMed

    Dubravac, Terry; Gahan, Thomas F; Pentella, Michael A

    2013-12-01

    With the availability of 4th generation HIV diagnostic tests which are capable of detecting acute infection, Iowa evaluated the 3rd and 4th generation HIV test and compared the performance of these products in a low incidence population. This study was conducted to evaluate the performance of an HIV antigen/antibody combination (4th generation) assay compared to an EIA 3rd generation assay. Over a 4 month period, 2037 specimens submitted for HIV screening were tested by Bio-Rad GS HIV-1/HIV-2 Plus O EIA and the Abbott Architect i1000SR HIV Ag/Ab Combo. The performance characteristics of sensitivity, specificity, positive predictive value and negative predictive value were determined. Of the 2037 specimens tested, there were 13 (0.64%) true positives detected. None of the positive specimens were from patients in the acute phase of infection. The Abbott antigen/antibody combo assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.85%, 81.25%, and 100% respectively. The Bio-Rad EIA assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.80%, 76.47% and 100%, respectively. The EIA had four false positive results which tested negative by the antigen/antibody assay and western blot. In a low-incidence state where early infections are less commonly encountered, the EIA assay and the antigen/antibody assay performed with near equivalency. The antigen/antibody assay had one less false positive result. While no patients were detected in the acute stage of infection, the use of the antigen/antibody assay presents the opportunity to detect an infected patient sooner and prevent transmission to others. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Development, optimization, and single laboratory validation of an event-specific real-time PCR method for the detection and quantification of Golden Rice 2 using a novel taxon-specific assay.

    PubMed

    Jacchia, Sara; Nardini, Elena; Savini, Christian; Petrillo, Mauro; Angers-Loustau, Alexandre; Shim, Jung-Hyun; Trijatmiko, Kurniawan; Kreysa, Joachim; Mazzara, Marco

    2015-02-18

    In this study, we developed, optimized, and in-house validated a real-time PCR method for the event-specific detection and quantification of Golden Rice 2, a genetically modified rice with provitamin A in the grain. We optimized and evaluated the performance of the taxon (targeting rice Phospholipase D α2 gene)- and event (targeting the 3' insert-to-plant DNA junction)-specific assays that compose the method as independent modules, using haploid genome equivalents as unit of measurement. We verified the specificity of the two real-time PCR assays and determined their dynamic range, limit of quantification, limit of detection, and robustness. We also confirmed that the taxon-specific DNA sequence is present in single copy in the rice genome and verified its stability of amplification across 132 rice varieties. A relative quantification experiment evidenced the correct performance of the two assays when used in combination.

  4. Development of a human-specific B. thetaiotaomicron IMS ...

    EPA Pesticide Factsheets

    Immunomagnetic separation/adenosine triphosphate (IMS/ATP) assays utilize paramagnetic beads and target-specific antibodies to isolate target organisms. Following isolation, adenosine tri-phosphate (ATP) is extracted from the target population and quantified. An inversely-coupled (Inv-IMS/ATP)assay for detection of Bacteroides thetaiotaomicron was developed and applied for rapid detection of human-associated fecal contamination in surface waters in Baja California. Specificity of the assay was tested against challenge solutions of varying concentrations of dog, gull, horse and chicken feces, and a field validation survey of coastal and WWTP effluent water quality in Rosarito and Enseneda, Baja California was conducted. Inv IMS/ATP measurements made shown to be specific and sensitive to human fecal contamination. At test concentrations of less than 1000 MPN ENT/100 mL, sensitivity and specificity of the assay both exceeded 80%. Moreover, the Inv-IMS/ATP assay yielded measurements of viable B. thetaiotaomicron that were comparable to the HF183 human marker in complex surface waters impacted with both wastewater and runoff, and the Inv-IMS/ATP assay was able to effectively differentiate between surface waters impacted with adequately and inadequately treated wastewater. The Inv-IMS/ATP assays shows promise for rapid evaluation of recreational water quality in areas where access to more expensive methods is limited and in areas where water quality in unpredicta

  5. A Novel Loop-Mediated Isothermal Amplification Assay for Serogroup Identification of Neisseria meningitidis in Cerebrospinal Fluid

    PubMed Central

    Lee, DoKyung; Kim, Eun Jin; Kilgore, Paul E.; Takahashi, Hideyuki; Ohnishi, Makoto; Tomono, Jun; Miyamoto, Shigehiko; Omagari, Daisuke; Kim, Dong Wook; Seki, Mitsuko

    2016-01-01

    We have developed a novel Neisseria meningitidis serogroup-specific loop-mediated isothermal amplification (LAMP) assay for six of the most common meningococcal serogroups (A, B, C, W, X, and Y). The assay was evaluated using a set of 31 meningococcal LAMP assay positive cerebrospinal fluid (CSF) specimens from 1574 children with suspected meningitis identified in prospective surveillance between 1998 and 2002 in Vietnam, China, and Korea. Primer specificity was validated using 15 N. meningitidis strains (including serogroups A, B, C, E, W, X, Y, and Z) and 19 non-N. meningitidis species. The N. meningitidis serogroup LAMP detected down to ten copies and 100 colony-forming units per reaction. Twenty-nine CSF had N. meningitidis serogroup identified by LAMP compared with two CSF in which N. meningitidis serogroup was identified by culture and multi-locus sequence typing. This is the first report of a serogroup-specific identification assay for N. meningitidis using the LAMP method. Our results suggest that this assay will be a rapid, sensitive, and uniquely serogroup-specific assay with potential for application in clinical laboratories and public health surveillance systems. PMID:26793181

  6. Anal lymphogranuloma venereum infection screening with IgA anti-Chlamydia trachomatis-specific major outer membrane protein serology.

    PubMed

    de Vries, Henry J C; Smelov, Vitaly; Ouburg, Sander; Pleijster, Jolein; Geskus, Ronald B; Speksnijder, Arjen G C L; Fennema, Johannes S A; Morré, Servaas A

    2010-12-01

    Anal lymphogranuloma venereum (LGV) infections, caused by Chlamydia trachomatis biovar L (Ct+/LGV+), are endemic among men who have sex with men (MSM). Anal non-LGV biovar Ct infections (Ct+/LGV-) can be eradicated with 1 week doxycycline, whereas Ct+/LGV+ infections require 3-week doxycycline. To differentiate Ct+/LGV+ from Ct+/LGV- infections, biovar-specific Nucleic Acid Amplification Test (NAAT) are standard, but also expensive and laborious. A chlamydia-specific serological assay could serve as an alternative test. MSM were screened for anal Ct+/LGV+ and Ct+/LGV- infections with a commercial nonspecific NAAT and an in house biovar L-specific NAAT. Serum samples were evaluated with chlamydia-specific anti-Major Outer Membrane Protein (MOMP) and antilipopolysaccharide assays of IgA and IgG classes. Asymptomatic patients were identified as: (1) no anal complaints or (2) no microscopic inflammation (i.e., <10 leucocytes per high power field in anal smears). The best differentiating assay was subsequently evaluated in 100 Ct+/LGV+ and 100 Ct+/LGV- MSM using different cut-off points. The anti-MOMP IgA assay was the most accurate to differentiate Ct+/LGV+ (n = 42) from Ct+/LGV- (n = 19) with 85.7% sensitivity (95% confidence interval [CI], 72.2-93.3) and 84.2% specificity (95% CI, 62.4-94.5), even among asymptomatic patients. In a population comprising 98 Ct+/LGV+ and 105 Ct+/LGV- patients, the anti-MOMP IgA assay scored most accurate when the cut-off point was set to 2.0 with 75.5% (95% CI, 65.8-83.6) sensitivity and 74.3% (95% CI, 64.8-82.3) specificity. The IgA anti-MOMP assay can identify a considerable proportion of the (asymptomatic) anal LGV infections correctly. Yet, biovar L-specific NAAT are still the preferred diagnostic tests in clinical settings.

  7. A multiplex PCR assay for the rapid and sensitive detection of methicillin-resistant Staphylococcus aureus and simultaneous discrimination of Staphylococcus aureus from coagulase-negative staphylococci.

    PubMed

    Xu, Benjin; Liu, Ling; Liu, Li; Li, Xinping; Li, Xiaofang; Wang, Xin

    2012-11-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a global health concern, which had been detected in food and food production animals. Conventional testing for detection of MRSA takes 3 to 5 d to yield complete information of the organism and its antibiotic sensitivity pattern. So, a rapid method is needed to diagnose and treat the MRSA infections. The present study focused on the development of a multiplex PCR assay for the rapid and sensitive detection of MRSA. The assay simultaneously detected 4 genes, namely, 16S rRNA of the Staphylococcus genus, femA of S. aureus, mecA that encodes methicillin resistance, and one internal control. It was rapid and yielded results within 4 h. The analytical sensitivity and specificity of the multiplex PCR assay was evaluated by comparing it with the conventional method. The analytical sensitivity of the multiplex PCR assay at the DNA level was 10 ng DNA. The analytical specificity was evaluated with 10 reference staphylococci strains and was 100%. The diagnostic evaluation of MRSA was carried out using 360 foodborne staphylococci isolates, and showed 99.1% of specificity, 96.4% of sensitivity, 97.5% of positive predictive value, and 97.3% of negative predictive value compared to the conventional method. The inclusion of an internal control in the multiplex PCR assay is important to exclude false-negative cases. This test can be used as an effective diagnostic and surveillance tool to investigate the spread and emergence of MRSA. © 2012 Institute of Food Technologists®

  8. Development of Quantitative PCR Assays Targeting the 16S rRNA Genes of Enterococcus spp. and Their Application to the Identification of Enterococcus Species in Environmental Samples

    PubMed Central

    Ryu, Hodon; Henson, Michael; Elk, Michael; Toledo-Hernandez, Carlos; Griffith, John; Blackwood, Denene; Noble, Rachel; Gourmelon, Michèle; Glassmeyer, Susan

    2013-01-01

    The detection of environmental enterococci has been determined primarily by using culture-based techniques that might exclude some enterococcal species as well as those that are nonculturable. To address this, the relative abundances of enterococci were examined by challenging fecal and water samples against a currently available genus-specific assay (Entero1). To determine the diversity of enterococcal species, 16S rRNA gene-based group-specific quantitative PCR (qPCR) assays were developed and evaluated against eight of the most common environmental enterococcal species. Partial 16S rRNA gene sequences of 439 presumptive environmental enterococcal strains were analyzed to study further the diversity of enterococci and to confirm the specificities of group-specific assays. The group-specific qPCR assays showed relatively high amplification rates with targeted species (>98%), although some assays cross-amplified with nontargeted species (1.3 to 6.5%). The results with the group-specific assays also showed that different enterococcal species co-occurred in most fecal samples. The most abundant enterococci in water and fecal samples were Enterococcus faecalis and Enterococcus faecium, although we identified more water isolates as Enterococcus casseliflavus than as any of the other species. The prevalence of the Entero1 marker was in agreement with the combined number of positive signals determined by the group-specific assays in most fecal samples, except in gull feces. On the other hand, the number of group-specific assay signals was lower in all water samples tested, suggesting that other enterococcal species are present in these samples. While the results highlight the value of genus- and group-specific assays for detecting the major enterococcal groups in environmental water samples, additional studies are needed to determine further the diversity, distributions, and relative abundances of all enterococcal species found in water. PMID:23087032

  9. Development of a luciferase based viral inhibition assay to evaluate vaccine induced CD8 T-cell responses

    PubMed Central

    Naarding, Marloes A.; Fernandez-Fernandez, Natalia; Kappes, John C.; Hayes, Peter; Ahmed, Tina; Icyuz, Mert; Edmonds, Tara G.; Bergin, Philip; Anzala, Omu; Hanke, Tomas; Clark, Lorna; Cox, Josephine H.; Cormier, Emmanuel; Ochsenbauer, Christina; Gilmour, Jill

    2014-01-01

    Emergence of SIV and HIV specific CD8 T cells has been shown to correlate with control of in vivo replication. Poor correlation between IFN-γ ELISPOT responses and in vivo control of the virus has triggered the development of more relevant assays to assess functional HIV-1 specific CD8 T-cell responses for the evaluation and prioritization of new HIV-1 vaccine candidates. We previously established a viral inhibition assay (VIA) that measures the ability of vaccine-induced CD8 T-cell responses to inhibit viral replication in autologous CD4 T cells. In this assay, viral replication is determined by measuring p24 in the culture supernatant. Here we describe the development of a novel VIA, referred to as IMC LucR VIA that exploits replication-competent HIV-1 infectious molecular clones (IMCs) in which the complete proviral genome is strain-specific and which express the Renilla luciferase (LucR) gene to determine viral growth and inhibition. The introduction of the luciferase readout does provide significant improvement of the read out time. In addition to switching to the LucR read out, changes made to the overall protocol resulted in the miniaturization of the assay from a 48 to a 96-well plate format, which preserved sample and allowed for the introduction of replicates. The overall assay time was reduced from 13 to 8 days. The assay has a high degree of specificity, and the previously observed non-specific background inhibition in cells from HIV-1 negative volunteers has been reduced dramatically. Importantly, we observed an increase in positive responses, indicating an improvement in sensitivity compared to the original VIA. Currently, only a limited number of “whole-genome” IMC-LucR viruses are available and our efforts will focus on expanding the panel to better evaluate anti-viral breadth. Overall, we believe the IMC LucR VIA provides a platform to assess functional CD8 T-cell responses in large-scale clinical trial testing, which will enhance the ability to select the most promising HIV-1 vaccine candidates capable of controlling HIV-1 replication in vivo. PMID:24291126

  10. Loop-mediated isothermal amplification assay for rapid and sensitive detection of sheep pox and goat pox viruses in clinical samples.

    PubMed

    Venkatesan, G; Balamurugan, V; Bhanuprakash, V; Singh, R K; Pandey, A B

    2016-06-01

    A Loop-mediated isothermal amplification (LAMP) assay targeting the highly conserved DNA polymerase gene of capripox virus genome was developed and evaluated for rapid detection of sheep pox and goat pox viruses. The optimized LAMP assay is found specific and sensitive for amplification of target DNA with a diagnostic sensitivity and specificity of 96.6% and 100% respectively compared to quantitative PCR. The detection rate of LAMP, PCR and Q-PCR assays is found to be 81.5%, 67% and 83% respectively. This LAMP assay has the potential for rapid clinical diagnosis and surveillance of sheep pox and goat pox in field diagnostic laboratories. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Comparison of the AdvanSure human papillomavirus screening real-time PCR, the Abbott RealTime High Risk human papillomavirus test, and the Hybrid Capture human papillomavirus DNA test for the detection of human papillomavirus.

    PubMed

    Hwang, Yusun; Lee, Miae

    2012-05-01

    We evaluated the performance of various commercial assays for the molecular detection of human papillomavirus (HPV); the recently developed AdvanSure HPV Screening real-time PCR assay (AdvanSure PCR) and the Abbott RealTime High Risk HPV PCR assay (Abbott PCR) were compared with the Hybrid Capture 2 HPV DNA Test (HC2). All 3 tests were performed on 177 samples, and any sample that showed a discrepancy in any of the 3 tests was genotyped using INNO-LiPA HPV genotyping and/or sequencing. On the basis of these results, we obtained a consensus HPV result, and the performance of each test was evaluated. We also evaluated high-risk HPV 16/18 detection by using the 2 real-time PCR assays. Among the 177 samples, 65 were negative and 75 were positive in all 3 assays; however, the results of the 3 assays with 37 samples were discrepant. Compared with the consensus HPV result, the sensitivities and specificities of HC2, AdvanSure PCR, and Abbott PCR were 97.6%, 91.7%, and 86.9% and 83.9%, 98.8%, and 100.0%, respectively. For HPV type 16/18 detection, the concordance rate between the AdvanSure PCR and Abbott PCR assays was 98.3%; however, 3 samples were discrepant (positive in AdvanSure PCR and negative in Abbott PCR) and were confirmed as HPV type 16 by INNO-LiPA genotyping and/or sequencing. For HPV detection, the AdvanSure HPV Screening real-time PCR assay and the Abbott PCR assay are less sensitive but more specific than the HC2 assay, but can simultaneously differentiate type 16/18 HPV from other types.

  12. Exploiting Bacterial Whole-Genome Sequencing Data for Evaluation of Diagnostic Assays: Campylobacter Species Identification as a Case Study.

    PubMed

    Jansen van Rensburg, Melissa J; Swift, Craig; Cody, Alison J; Jenkins, Claire; Maiden, Martin C J

    2016-12-01

    The application of whole-genome sequencing (WGS) to problems in clinical microbiology has had a major impact on the field. Clinical laboratories are now using WGS for pathogen identification, antimicrobial susceptibility testing, and epidemiological typing. WGS data also represent a valuable resource for the development and evaluation of molecular diagnostic assays, which continue to play an important role in clinical microbiology. To demonstrate this application of WGS, this study used publicly available genomic data to evaluate a duplex real-time PCR (RT-PCR) assay that targets mapA and ceuE for the detection of Campylobacter jejuni and Campylobacter coli, leading global causes of bacterial gastroenteritis. In silico analyses of mapA and ceuE primer and probe sequences from 1,713 genetically diverse C. jejuni and C. coli genomes, supported by RT-PCR testing, indicated that the assay was robust, with 1,707 (99.7%) isolates correctly identified. The high specificity of the mapA-ceuE assay was the result of interspecies diversity and intraspecies conservation of the target genes in C. jejuni and C. coli Rare instances of a lack of specificity among C. coli isolates were due to introgression in mapA or sequence diversity in ceuE The results of this study illustrate how WGS can be exploited to evaluate molecular diagnostic assays by using publicly available data, online databases, and open-source software. Copyright © 2016 Jansen van Rensburg et al.

  13. Exploiting Bacterial Whole-Genome Sequencing Data for Evaluation of Diagnostic Assays: Campylobacter Species Identification as a Case Study

    PubMed Central

    Jansen van Rensburg, Melissa J.; Swift, Craig; Cody, Alison J.; Jenkins, Claire

    2016-01-01

    The application of whole-genome sequencing (WGS) to problems in clinical microbiology has had a major impact on the field. Clinical laboratories are now using WGS for pathogen identification, antimicrobial susceptibility testing, and epidemiological typing. WGS data also represent a valuable resource for the development and evaluation of molecular diagnostic assays, which continue to play an important role in clinical microbiology. To demonstrate this application of WGS, this study used publicly available genomic data to evaluate a duplex real-time PCR (RT-PCR) assay that targets mapA and ceuE for the detection of Campylobacter jejuni and Campylobacter coli, leading global causes of bacterial gastroenteritis. In silico analyses of mapA and ceuE primer and probe sequences from 1,713 genetically diverse C. jejuni and C. coli genomes, supported by RT-PCR testing, indicated that the assay was robust, with 1,707 (99.7%) isolates correctly identified. The high specificity of the mapA-ceuE assay was the result of interspecies diversity and intraspecies conservation of the target genes in C. jejuni and C. coli. Rare instances of a lack of specificity among C. coli isolates were due to introgression in mapA or sequence diversity in ceuE. The results of this study illustrate how WGS can be exploited to evaluate molecular diagnostic assays by using publicly available data, online databases, and open-source software. PMID:27733632

  14. Rapid and specific detection of Salmonella in water samples using real-time PCR and High Resolution Melt (HRM) curve analysis.

    PubMed

    van Blerk, G N; Leibach, L; Mabunda, A; Chapman, A; Louw, D

    2011-01-01

    A real-time PCR assay combined with a pre-enrichment step for the specific and rapid detection of Salmonella in water samples is described. Following amplification of the invA gene target, High Resolution Melt (HRM) curve analysis was used to discriminate between products formed and to positively identify invA amplification. The real-time PCR assay was evaluated for specificity and sensitivity. The assay displayed 100% specificity for Salmonella and combined with a 16-18 h non-selective pre-enrichment step, the assay proved to be highly sensitive with a detection limit of 1.0 CFU/ml for surface water samples. The detection assay also demonstrated a high intra-run and inter-run repeatability with very little variation in invA amplicon melting temperature. When applied to water samples received routinely by the laboratory, the assay showed the presence of Salmonella in particularly surface water and treated effluent samples. Using the HRM based assay, the time required for Salmonella detection was drastically shortened to less than 24 h compared to several days when using standard culturing methods. This assay provides a useful tool for routine water quality monitoring as well as for quick screening during disease outbreaks.

  15. Rapid Multiplex Assay for Serotyping Pneumococci with Monoclonal and Polyclonal Antibodies

    PubMed Central

    Yu, Jigui; Lin, Jisheng; Benjamin, William H.; Waites, Ken B.; Lee, Che-hung; Nahm, Moon H.

    2005-01-01

    We have developed and characterized a rapid semiautomated pneumococcal serotyping system incorporating a pneumococcal lysate preparation protocol and a multiplex serotyping assay. The lysate preparation incorporates a bile solubility test to confirm pneumococcal identification that also enhances assay specificity. The multiplex serotyping assay consists of 24 assays specific for 36 serotypes: serotypes 1, 2, 3, 4, 5, 6A, 6B, 7A/7F, 8, 9L/9N, 9V, 10A/10B/39/(33C), 11A/11D/11F, 12A/12B/12F, 14, 15B/(15C), 17F, 18C, 19A, 19F, 20, 22A/22F, 23F, and 33A/33F. The multiplex assay requires a flow cytometer, two sets of latex particles coated with pneumococcal polysaccharides, and serotype-specific antibodies. Fourteen newly developed monoclonal antibodies specific for common serotypes and a pool of polyclonal rabbit sera for some of the less-common serotypes are used. The two monoclonal antibodies specific for serotypes 18C and 23F recognize serotype-specific epitopes that have not been previously described. These monoclonal antibodies make the identification of the 14 common serotypes invariant. The specificity of the serotyping assay is fully characterized with pneumococci of all known (i.e., 90) serotypes. The assay is sensitive enough to use bacterial lysates diluted 20 fold. Our serotyping system can identify not only all the serotypes in pneumococcal vaccines but also most (>90%) of clinical isolates. This system should be very useful in serotyping clinical isolates for evaluating pneumococcal vaccine efficacy. PMID:15634965

  16. Evaluation of two real time PCR assays for the detection of bacterial DNA in amniotic fluid.

    PubMed

    Girón de Velasco-Sada, Patricia; Falces-Romero, Iker; Quiles-Melero, Inmaculada; García-Perea, Adela; Mingorance, Jesús

    2018-01-01

    The aim of this study was to evaluate two non-commercial Real-Time PCR assays for the detection of microorganisms in amniotic fluid followed by identification by pyrosequencing. We collected 126 amniotic fluids from 2010 to 2015 for the evaluation of two Real-Time PCR assays for detection of bacterial DNA in amniotic fluid (16S Universal PCR and Ureaplasma spp. specific PCR). The method was developed in the Department of Microbiology of the University Hospital La Paz. Thirty-seven samples (29.3%) were positive by PCR/pyrosequencing and/or culture, 4 of them were mixed cultures with Ureaplasma urealyticum. The Universal 16S Real-Time PCR was compared with the standard culture (81.8% sensitivity, 97.4% specificity, 75% positive predictive value, 98% negative predictive value). The Ureaplasma spp. specific Real-Time PCR was compared with the Ureaplasma/Mycoplasma specific culture (92.3% sensitivity, 89.4% specificity, 50% positive predictive value, 99% negative predictive value) with statistically significant difference (p=0.005). Ureaplasma spp. PCR shows a rapid response time (5h from DNA extraction until pyrosequencing) when comparing with culture (48h). So, the response time of bacteriological diagnosis in suspected chorioamnionitis is reduced. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Evaluation of Sensitivity and Specificity Performance of Elecsys HTLV-I/II Assay in a Multicenter Study in Europe and Japan.

    PubMed

    Laperche, Syria; Sauleda, Silvia; Piron, Maria; Mühlbacher, Annelies; Schennach, Harald; Schottstedt, Volkmar; Queirós, Lucinda; Uno, Naoki; Yanagihara, Katsunori; Imdahl, Roland; Hey, Ariann; Klinkicht, Markus; Melchior, Walter; Muench, Peter; Watanabe, Toshiki

    2017-07-01

    Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection. Copyright © 2017 Laperche et al.

  18. Evaluation of Sensitivity and Specificity Performance of Elecsys HTLV-I/II Assay in a Multicenter Study in Europe and Japan

    PubMed Central

    Sauleda, Silvia; Piron, Maria; Mühlbacher, Annelies; Schennach, Harald; Schottstedt, Volkmar; Queirós, Lucinda; Uno, Naoki; Yanagihara, Katsunori; Imdahl, Roland; Hey, Ariann; Klinkicht, Markus; Melchior, Walter; Muench, Peter; Watanabe, Toshiki

    2017-01-01

    ABSTRACT Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection. PMID:28468860

  19. Development of a rapid diagnostic assay for the detection of tomato chlorotic dwarf viroid based on isothermal reverse-transcription-recombinase polymerase amplification.

    PubMed

    Hammond, Rosemarie W; Zhang, Shulu

    2016-10-01

    A molecular diagnostic assay utilizing reverse transcription-recombinase polymerase amplification (RT-RPA) at an isothermal constant temperature of 39°C and target-specific primers and probe were developed for the rapid, sensitive, and specific detection of tomato chlorotic dwarf viroid (TCDVd) in infected leaf and seed tissues. The performance of the AmplifyRP(®) Acceler8™ RT-RPA diagnostic assay, utilizing a lateral flow strip contained within an amplicon detection chamber, was evaluated and the results were compared with a standard RT-PCR assay. The AmplifyRP(®) Acceler8™ assay was specific for TCDVd in leaf and seed tissues, its sensitivity was comparable to conventional RT-PCR in leaf tissues, and it does not require extensive sample purification, specialized equipment, or technical expertise. This is the first report utilizing an RT-RPA assay to detect viroids and the assay can be used both in the laboratory and in the field for TCDVd detection. Published by Elsevier B.V.

  20. Field-based performance of three pre-market rapid hepatitis C virus antibody assays in STAHR (Study to Assess Hepatitis C Risk) among young adults who inject drugs in San Diego, CA.

    PubMed

    Jewett, A; Smith, B D; Garfein, R S; Cuevas-Mota, J; Teshale, E H; Weinbaum, C M

    2012-07-01

    Approximately 4.1 million Americans are estimated to have been infected with hepatitis C virus (HCV), 45-85% of whom are unaware of their infection. Persons who inject drugs (PWID) account for 55.8% of all persons with HCV antibody (anti-HCV) in the U.S. PWID have limited access to healthcare and are infrequently tested for anti-HCV using conventional laboratory assays. To evaluate performance characteristics (sensitivity and specificity) of three, pre-market rapid point-of-care tests (one oral fluid and two finger-stick assays) from two manufacturers (Chembio and MedMira) in settings providing services to young adult PWID in San Diego, CA. Behavioral risk assessment surveys and testing for HCV were conducted among persons who reported injection drug use (IDU) within the past 6 months as part of the Study to Assess Hepatitis C Risk (STAHR) among PWID aged 18-40 years in 2009-2010. Sensitivity and specificity of the rapid anti-HCV assays were evaluated among STAHR participants, using two commonly used testing algorithms. Variability in sensitivity (76.6-97.1%) and specificity (99.0-100.0%) was found across assays. The highest sensitivity achieved for the Chembio finger-stick blood, Chembio oral fluid and MedMira finger-stick blood tests was 97.1%, 85.4% and 80.0% respectively; the highest specificity was 99.0%, 100.0% and 100.0%, respectively. In multivariate analysis false negative anti-HCV results were associated with female sex for the MedMira blood assay. Sensitive anti-HCV rapid assays are appropriate and feasible for high-prevalence, high-risk populations such as young PWID. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Development and evaluation of a 28S rRNA gene-based nested PCR assay for P. falciparum and P. vivax

    PubMed Central

    Pakalapati, Deepak; Garg, Shilpi; Middha, Sheetal; Acharya, Jyoti; Subudhi, Amit K; Boopathi, Arunachalam P; Saxena, Vishal; Kochar, Sanjay K; Kochar, Dhanpat K; Das, Ashis

    2013-01-01

    The 28S rRNA gene was amplified and sequenced from P. falciparum and P. vivax isolates collected from northwest India. Based upon the sequence diversity of the Plasmodium 28SrRNA gene in comparison with its human counterpart, various nested polymerase chain reaction (PCR) primers were designed from the 3R region of the 28SrRNA gene and evaluated on field isolates. This is the first report demonstrating the utility of this gene for species-specific diagnosis of malaria for these two species, prevalent in India. The initial evaluation on 363 clinical isolates indicated that, in comparison with microscopy, which showed sensitivity and specificity of 85.39% and 100% respectively, the sensitivity and specificity of the nested PCR assay was found to be 99.08% and 100% respectively. This assay was also successful in detecting mixed infections that are undetected by microscopy. Our results demonstrate the utility of the 28S rRNA gene as a diagnostic target for the detection of the major plasmodial species infecting humans. PMID:23816509

  2. Evaluation of a newly developed quantitative heart-type fatty acid binding protein assay based on fluorescence immunochromatography using specific monoclonal antibodies.

    PubMed

    Kang, Keren; Wu, Peidian; Li, Wenmei; Tang, Shixing; Wang, Jihua; Luo, Xiaochun; Xie, Mingquan

    2015-01-01

    To develop a rapid, sensitive and specific assay for quantification of serum heart-type fatty acid binding protein (H-FABP) based on immunofluorescence of specific monoclonal antibodies. We generated novel H-FABP-directed monoclonal antibodies by cloning of spleen cells of mice immunized with H-FABP. Epitopes were mapped and antigen affinity was assessed by surface plasmon resonance (SPR). The H-FABP specific monoclonal antibodies were coupled to fluorescent beads and sprayed onto a nitrocellulose membrane facilitating quantification of H-FABP by immunofluorescence. Reagent cross-reactivity, interference resistance, accuracy and sensitivity were examined. A total of 103 clinical samples were used to compare the sensitivity and specificity of the new assay to a commercially available Randox kit. This new assay could be finished within 15 min, with sensitivity reaching 1 ng/ml. In a trial of 103 clinical serum samples, the new testing kit results were highly correlated with those from the Randox kit (R(2) = 0.9707). Using the Randox kit as the reference kit, the sensitivity of the new assay was 98.25%, and specificity was 100%. An immunofluorescence-based H-FABP assay employing novel monoclonal antibodies could rapidly, specifically and sensitively detect H-FABP in serum samples, providing an effective method for rapid clinical assessment of H-FABP index in the clinic.

  3. Development and evaluation of a blocking enzyme-linked immunosorbent assay and virus neutralization assay to detect antibodies to viral hemorrhagic septicemia virus

    USGS Publications Warehouse

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas M.; Toohey-Kurth, Kathy

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV.

  4. Epitope characterization of the ADA response directed against a targeted immunocytokine.

    PubMed

    Stubenrauch, Kay; Künzel, Christian; Vogel, Rudolf; Tuerck, Dietrich; Schick, Eginhard; Heinrich, Julia

    2015-10-10

    Targeted immunocytokines (TICs) display potent activity in selective tumor suppression. This class of multi domain biotherapeutics (MDBs) is composed of the three major domains Fab, Fc, and a cytokine which may induce a complex polyclonal anti-drug antibody (ADA) response. However, classical ADA assays usually are not suitable to specify ADAs and to identify the immunogenic domains of a TIC. The purpose of the present study was to establish epitope characterization of ADA responses in order to specify immunogenic responses against a TIC and their direct impact on the pharmacokinetic profile, safety, and efficacy. Based on standard ADA screening and confirmation assays, respectively, domain detection assays (DDAs) and domain competition assays (DCAs) were established and compared by the use of 12 ADA-positive samples obtained from a cynomolgus monkey study in early development. Both domain-specific assays were sensitive enough to preserve the positive screening assay result and revealed an overall accordance for the evaluation of domain-specific ADA responses. About half of the samples displayed one ADA specificity, either for the Fab or for the cytokine (Cy) domain, and the remaining samples showed a combination of Fab-specific and Cy-specific ADA fractions. Fc-specific ADAs occurred in only one sample. In-depth comparison of DCAs and DDAs showed that both assays appeared to be appropriate to assess multi-specific ADA responses as well as minor ADA fractions. An advantage of DCAs is typically a fast and easy assay establishment, whereas, DDAs in some cases may be superior to assess low abundant ADAs in multi-specific responses. Our results reveal that both approaches benefit from thorough reagent development as an essential precondition for reliable epitope characterization of ADA responses. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Detection of infectious bronchitis virus with the use of real-time quantitative reverse transcriptase-PCR and correlation with virus detection in embryonated eggs.

    PubMed

    Roh, Ha-Jung; Hilt, Deborah A; Jackwood, Mark W

    2014-09-01

    Real-time quantitative reverse transcriptase-polymerase chain reaction (qRT-PCR) assays have been used to detect the presence of challenge virus when the efficacy of infectious bronchitis virus (IBV) vaccine against field viruses is being experimentally evaluated. However, federal guidelines for licensing IBV vaccines indicate that challenge-virus detection following vaccination is to be conducted in embryonated eggs. In this study, we examined qRT-PCR data with the use of universal and type-specific primers and probe sets for IBV detection and compared those data with challenge-virus detection in embryonated eggs to determine if the two methods of evaluating vaccine efficacy are comparable. In addition, we tested the qRT-PCR assays on thermocyclers from two different manufacturers. We found the universal IBV primers and probe set to be comparable to challenge-virus detection in embryonated eggs. However, for some IBV types (Mass41 and Conn on the SmartCycler II and Ark, Mass41, Conn, and GA98 on the ABI 7500) the qRT-PCR assay was more sensitive than virus detection in embryonated eggs. This may simply be due to the universal IBV qRT-PCR assay being more sensitive than virus detection in eggs or to the assay detecting nucleic acid from nonviable virus. This finding is important and needs to be considered when evaluating challenge-virus detection for vaccination and challenge studies, because qRT-PCR could potentially identify positive birds that would otherwise be negative by virus detection in embryonated eggs; thus it could lead to a more stringent measure of vaccine efficacy. We also found that the IBV type-specific primers and probe sets designed in this study were in general less sensitive than the universal IBV primers and probe set. Only the Ark-DPI-spedcific assay on the SmartCycler II and the Ark-DPI-, Mass41-, and DE072/GA98- (for detection of GA98 virus only) specific assays on the ABI 7500 were comparable in sensitivity to virus detection in eggs. We found that a number of variables, including the virus type examined, primers and probe efficiency and stability, and assay conditions, including thermocycler platform, can affect the data obtained from qRT-PCR assays. These results indicate that qRT-PCR assays can be used to detect IBV challenge virus, but each assay, including the assay conditions and thermocycler, should be individually evaluated if those data are expected to be comparable to virus detection in embryonated eggs.

  6. Identification of six Listeria species by real-time PCR assay.

    PubMed

    Hage, E; Mpamugo, O; Ohai, C; Sapkota, S; Swift, C; Wooldridge, D; Amar, C F L

    2014-06-01

    The Listeria genus comprises 10 recognized species. Listeria monocytogenes causes listeriosis in humans and other animals primarily via contaminated food or animal feed. Listeria ivanovii causes listeriosis in animals and on rare occasions in humans. The identification of nonpathogenic species of Listeria in foods indicates that conditions exist that support the growth of pathogenic strains and is used to facilitate the implementation of control and prevention measures. This study shows the development and evaluation of a 5'exonuclease real-time PCR assay for the rapid identification of Listeria seeligeri, Listeria welshimeri, L. monocytogenes, L. ivanovii, Listeria grayi and Listeria innocua. The assay consists of two triplexes that were evaluated using 53 cultures of Gram-positive bacteria, including 49 Listeria spp. from human, animal, food or food-processing environments. The assay was rapid, specific and reproducible and could identify each of the six species from a mixture of strains. The developed assay proved to be a powerful means of rapidly identifying Listeria species and could be usefully implemented in busy specialist reference laboratories. The identification of species of Listeria from foods is important to monitor pathogenic strains and facilitates the implementation of control measures. This study shows the development and evaluation of a 5'exonuclease real-time PCR assay for the rapid identification of L. seeligeri, L. welshimeri, L. monocytogenes and L. ivanovii, L. grayi, L. innocua. The developed assay proved to be specific, rapid and reproducible and therefore could be implemented in busy specialist reference laboratories. © 2014 The Society for Applied Microbiology.

  7. A blood tumor marker combination assay produces high sensitivity and specificity for cancer according to the natural history.

    PubMed

    Kobayashi, Tsuneo

    2018-03-01

    Diagnosis using a specific tumor marker is difficult because the sensitivity of this detection method is under 20%. Herein, a tumor marker combination assay, combining growth-related tumor marker and associated tumor marker (Cancer, 73(7), 1994), was employed. This double-blind tumor marker combination assay (TMCA) showed 87.5% sensitivity as the results, but a low specificity, ranging from 30 to 76%. To overcome this low specificity, we exploited complex markers, a multivariate analysis and serum fractionation by biochemical biopsy. Thus, in this study, a combination of new techniques was used to re-evaluate these serum samples. Three serum panels, containing 90, 120, and 97 samples were obtained from the Mayo Clinic. The final results showed 80-90% sensitivity, 84-85% specificity, and 83-88% accuracy. We demonstrated a notable tumor marker combination assay with high accuracy. This TMCA should be applicable for primary cancer detection and recurrence prevention. © 2018 The Author. Cancer Medicine published by John Wiley & Sons Ltd.

  8. SNaPshot and StripAssay as Valuable Alternatives to Direct Sequencing for KRAS Mutation Detection in Colon Cancer Routine Diagnostics

    PubMed Central

    Fariña Sarasqueta, Arantza; Moerland, Elna; de Bruyne, Hanneke; de Graaf, Henk; Vrancken, Tamara; van Lijnschoten, Gesina; van den Brule, Adriaan J.C.

    2011-01-01

    Although direct sequencing is the gold standard for KRAS mutation detection in routine diagnostics, it remains laborious, time consuming, and not very sensitive. Our objective was to evaluate SNaPshot and the KRAS StripAssay as alternatives to sequencing for KRAS mutation detection in daily practice. KRAS exon 2–specific PCR followed by sequencing or by a SNaPshot reaction was performed. For the StripAssay, a mutant-enriched PCR was followed by hybridization to KRAS-specific probes bound to a nitrocellulose strip. To test sensitivities, dilution series of mutated DNA in wild-type DNA were made. Additionally, direct sequencing and SNaPshot were evaluated in 296 colon cancer samples. Detection limits of direct sequencing, SNaPshot, and StripAssay were 20%, 10%, and 1% tumor cells, respectively. Direct sequencing and SNaPshot can detect all 12 mutations in KRAS codons 12 and 13, whereas the StripAssay detects 10 of the most frequent ones. Workload and time to results are comparable for SNaPshot and direct sequencing. SNaPshot is flexible and easy to multiplex. The StripAssay is less time consuming for daily laboratory practice. SNaPshot is more flexible and slightly more sensitive than direct sequencing. The clinical evaluation showed comparable performances between direct sequencing and SNaPshot. The StripAssay is rapid and an extremely sensitive assay that could be considered when few tumor cells are available. However, found mutants should be confirmed to avoid risk of false positives. PMID:21354055

  9. Identification of Escherichia coli, Klebsiella pneumoniae, and Pseudomonas aeruginosa in Blood Cultures: a Multicenter Performance Evaluation of a Three-Color Peptide Nucleic Acid Fluorescence In Situ Hybridization Assay▿

    PubMed Central

    Della-Latta, Phyllis; Salimnia, Hossein; Painter, Theresa; Wu, Fann; Procop, Gary W.; Wilson, Deborah A.; Gillespie, Wendy; Mender, Alayna; Crystal, Benjamin S.

    2011-01-01

    A multicenter evaluation was undertaken to evaluate the performance of a new three-color peptide nucleic acid fluorescence in situ hybridization assay that identifies isolates directly from blood cultures positive for Gram-negative bacilli (GNB). The assay correctly identified 100% (186/186) of the Escherichia coli isolates, 99.1% (109/110) of the Klebsiella pneumoniae isolates, and 95.8% (46/48) of the Pseudomonas aeruginosa isolates in this study. Negative assay results were correctly obtained for 162 of 165 other GNB (specificity, 98.2%). PMID:21490185

  10. Evaluation of molecular markers for Phytophthora ramorum detection and identification: testing for specificity using a standardized library of isolates.

    PubMed

    Martin, F N; Coffey, M D; Zeller, K; Hamelin, R C; Tooley, P; Garbelotto, M; Hughes, K J D; Kubisiak, T; Bilodeau, G J; Levy, L; Blomquist, C; Berger, P H

    2009-04-01

    Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World Phytophthora Genetic Resource Collection for 315 isolates representing 60 described Phytophthora spp. as well as 11 taxonomically unclassified isolates. These were sent blind to collaborators in seven laboratories to evaluate published diagnostic procedures using conventional (based on internal transcribed spacer [ITS] and cytochrome oxidase gene [cox]1 and 2 spacer regions) and real-time polymerase chain reaction (based on ITS and cox1 and 2 spacer regions as well as beta-tubulin and elicitin genes). Single-strand conformation polymorphism (SSCP) analysis using an automated sequencer for data collection was also evaluated for identification of all species tested. In general, the procedures worked well, with varying levels of specificity observed among the different techniques. With few exceptions, all assays correctly identified all isolates of P. ramorum and low levels of false positives were observed for the mitochondrial cox spacer markers and most of the real-time assays based on nuclear markers (diagnostic specificity between 96.9 and 100%). The highest level of false positives was obtained with the conventional nested ITS procedure; however, this technique is not stand-alone and is used in conjunction with two other assays for diagnostic purposes. The results indicated that using multiple assays improved the accuracy of the results compared with looking at a single assay alone, in particular when the markers represented different genetic loci. The SSCP procedure accurately identified P. ramorum and was helpful in classification of a number of isolates to a species level. With one exception, all procedures accurately identified P. ramorum in blind evaluations of 60 field samples that included examples of plant infection by 11 other Phytophthora spp. The SSCP analysis identified eight of these species, with three identified to a species group.

  11. Use of High Throughput Screening Data in IARC Monograph ...

    EPA Pesticide Factsheets

    Purpose: Evaluation of carcinogenic mechanisms serves a critical role in IARC monograph evaluations, and can lead to “upgrade” or “downgrade” of the carcinogenicity conclusions based on human and animal evidence alone. Three recent IARC monograph Working Groups (110, 112, and 113) pioneered analysis of high throughput in vitro screening data from the U.S. Environmental Protection Agency’s ToxCast program in evaluations of carcinogenic mechanisms. Methods: For monograph 110, ToxCast assay data across multiple nuclear receptors were used to test the hypothesis that PFOA acts exclusively through the PPAR family of receptors, with activity profiles compared to several prototypical nuclear receptor-activating compounds. For monographs 112 and 113, ToxCast assays were systematically evaluated and used as an additional data stream in the overall evaluation of the mechanistic evidence. Specifically, ToxCast assays were mapped to 10 “key characteristics of carcinogens” recently identified by an IARC expert group, and chemicals’ bioactivity profiles were evaluated both in absolute terms (number of relevant assays positive for bioactivity) and relative terms (ranking with respect to other compounds evaluated by IARC, using the ToxPi methodology). Results: PFOA activates multiple nuclear receptors in addition to the PPAR family in the ToxCast assays. ToxCast assays offered substantial coverage for 5 of the 10 “key characteristics,” with the greates

  12. Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay Coupled with a Portable Device for Rapid Diagnosis of Ebola Virus Disease in Guinea

    PubMed Central

    Kurosaki, Yohei; Magassouba, N’Faly; Oloniniyi, Olamide K.; Cherif, Mahamoud S.; Sakabe, Saori; Takada, Ayato; Hirayama, Kenji; Yasuda, Jiro

    2016-01-01

    Given the current absence of specific drugs or vaccines for Ebola virus disease (EVD), rapid, sensitive, and reliable diagnostic methods are required to stem the transmission chain of the disease. We have developed a rapid detection assay for Zaire ebolavirus based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and coupled with a novel portable isothermal amplification and detection platform. The RT-LAMP assay is based on primer sets that target the untranscribed trailer region or nucleoprotein coding region of the viral RNA. The test could specifically detect viral RNAs of Central and West African Ebola virus strains within 15 minutes with no cross-reactivity to other hemorrhagic fever viruses and arboviruses, which cause febrile disease. The assay was evaluated using a total of 100 clinical specimens (serum, n = 44; oral swab, n = 56) collected from suspected EVD cases in Guinea. The specificity of this diagnostic test was 100% for both primer sets, while the sensitivity was 100% and 97.9% for the trailer and nucleoprotein primer sets, respectively, compared with a reference standard RT-PCR test. These observations suggest that our diagnostic assay is useful for identifying EVD cases, especially in the field or in settings with insufficient infrastructure. PMID:26900929

  13. Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay Coupled with a Portable Device for Rapid Diagnosis of Ebola Virus Disease in Guinea.

    PubMed

    Kurosaki, Yohei; Magassouba, N'Faly; Oloniniyi, Olamide K; Cherif, Mahamoud S; Sakabe, Saori; Takada, Ayato; Hirayama, Kenji; Yasuda, Jiro

    2016-02-01

    Given the current absence of specific drugs or vaccines for Ebola virus disease (EVD), rapid, sensitive, and reliable diagnostic methods are required to stem the transmission chain of the disease. We have developed a rapid detection assay for Zaire ebolavirus based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and coupled with a novel portable isothermal amplification and detection platform. The RT-LAMP assay is based on primer sets that target the untranscribed trailer region or nucleoprotein coding region of the viral RNA. The test could specifically detect viral RNAs of Central and West African Ebola virus strains within 15 minutes with no cross-reactivity to other hemorrhagic fever viruses and arboviruses, which cause febrile disease. The assay was evaluated using a total of 100 clinical specimens (serum, n = 44; oral swab, n = 56) collected from suspected EVD cases in Guinea. The specificity of this diagnostic test was 100% for both primer sets, while the sensitivity was 100% and 97.9% for the trailer and nucleoprotein primer sets, respectively, compared with a reference standard RT-PCR test. These observations suggest that our diagnostic assay is useful for identifying EVD cases, especially in the field or in settings with insufficient infrastructure.

  14. Performance and Specificity of the Covalently Linked Immunomagnetic Separation-ATP Method for Rapid Detection and Enumeration of Enterococci in Coastal Environments

    PubMed Central

    Zimmer-Faust, Amity G.; Thulsiraj, Vanessa; Ferguson, Donna

    2014-01-01

    The performance and specificity of the covalently linked immunomagnetic separation-ATP (Cov-IMS/ATP) method for the detection and enumeration of enterococci was evaluated in recreational waters. Cov-IMS/ATP performance was compared with standard methods: defined substrate technology (Enterolert; IDEXX Laboratories), membrane filtration (EPA Method 1600), and an Enterococcus-specific quantitative PCR (qPCR) assay (EPA Method A). We extend previous studies by (i) analyzing the stability of the relationship between the Cov-IMS/ATP method and culture-based methods at different field sites, (ii) evaluating specificity of the assay for seven ATCC Enterococcus species, (iii) identifying cross-reacting organisms binding the antibody-bead complexes with 16S rRNA gene sequencing and evaluating specificity of the assay to five nonenterococcus species, and (iv) conducting preliminary tests of preabsorption as a means of improving the assay. Cov-IMS/ATP was found to perform consistently and with strong agreement rates (based on exceedance/compliance with regulatory limits) of between 83% and 100% compared to the culture-based Enterolert method at a variety of sites with complex inputs. The Cov-IMS/ATP method is specific to five of seven different Enterococcus spp. tested. However, there is potential for nontarget bacteria to bind the antibody, which may be reduced by purification of the IgG serum with preabsorption at problematic sites. The findings of this study help to validate the Cov-IMS/ATP method, suggesting a predictable relationship between the Cov-IMS/ATP method and traditional culture-based methods, which will allow for more widespread application of this rapid and field-portable method for coastal water quality assessment. PMID:24561583

  15. Performance characteristics of the ARCHITECT anti-HCV assay.

    PubMed

    Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter

    2005-10-01

    The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.

  16. A Retrospective Assessment of Four Antigen Assays for the Detection of Invasive Candidiasis Among High-Risk Hospitalized Patients.

    PubMed

    Hartl, Barbara; Zeller, Iris; Manhart, Angelika; Selitsch, Brigitte; Lass-Flörl, Cornelia; Willinger, Birgit

    2018-06-01

    Because of their high mortality rates and non-specific symptoms, invasive Candida infections pose a huge diagnostic and therapeutic challenge. In this study, we evaluated the three mannan antigen assays Platelia, Platelia Plus and Serion, and the (1-3)-β-D-glucan assay Fungitell in a group of high-risk (hematological and surgical) patients. Test results of 305 patients hospitalized at the Vienna General Hospital and the University Hospital of Innsbruck were retrospectively analyzed. We assessed the test accuracy by means of descriptive statistics. Nine (2.95%) patients were affected by invasive candidiasis (IC), and 25 (8.2%) patients had a probable/possible infection. The majority of patients (271; 88.9%) showed no signs of infection. The Platelia and Serion mannan assays had a low sensitivity (65% and 52%, respectively), but high specificity (98% for both tests). The newer version of the Platelia assay, the Platelia Plus, had a higher sensitivity (85%) but a lower specificity (89%). The sensitivity of the Fungitell assay was high (100%), while its specificity was low (58%). The positive predictive values were 0.48 for the Platelia and 0.41 for the Serion assay, 0.26 for the Platelia Plus and 0.09 for the Fungitell assay. Our limited, retrospective study suggests the efficacy of mannan assays as screening (Platelia Plus) and confirmatory (Serion) tests, while the Fungitell assay can be used to exclude invasive Candida infections.

  17. Evaluation of a Rapid Fecal PCR Test for Detection of Mycobacterium avium subsp. paratuberculosis in Dairy Cattle▿

    PubMed Central

    Wells, Scott J.; Collins, Michael T.; Faaberg, Kay S.; Wees, Carrie; Tavornpanich, Saraya; Petrini, Kristine R.; Collins, James E.; Cernicchiaro, Natalia; Whitlock, Robert H.

    2006-01-01

    A high-throughput TaqMan PCR assay for detection of bovine paratuberculosis was evaluated by using fecal samples from 1,808 dairy cattle in seven naturally infected herds and 347 dairy cattle in seven herds considered free of paratuberculosis. Fecal, blood, and milk samples were submitted to laboratories where the PCR-based assay, three different fecal culture procedures for Mycobacterium avium subsp. paratuberculosis (centrifugation, sedimentation, and the BACTEC filter concentration method), two serologic enzyme-linked immunosorbent assays (ELISAs), and one milk ELISA were performed. Results from testing of dairy cattle in herds free of M. avium subsp. paratuberculosis showed that the PCR assay's specificity was 99.7%. Twenty-three percent of the dairy cows that were fecal culture positive by at least one of the three methods were positive by the PCR assay. By Bayesian non-“gold standard” analysis methods, the TaqMan PCR assay had a higher specificity than the serum ELISAs (99.3%; 95% confidence interval [CI] = 98.6 to 99.7%) and a test sensitivity similar to that of the serum ELISAs (29%; 95% CI = 24 to 35%). By classical methods, the estimated relative sensitivity of the fecal PCR assay was 4% for light and moderate fecal shedders (compared to 12 to 13% for the ELISAs) and 76% for heavy fecal shedders (compared to 67% for the milk ELISA). The PCR assay has higher sensitivity for detection of heavy fecal shedders than the evaluated milk ELISA but lower sensitivity than a serum or milk ELISA for detection of light and moderate fecal shedders. This assay can be used as a quick test for detection of cattle with heavy fecal shedding, those cattle with the highest risk of transmitting infection to susceptible cattle. PMID:16928884

  18. Evaluation of the reliability of maize reference assays for GMO quantification.

    PubMed

    Papazova, Nina; Zhang, David; Gruden, Kristina; Vojvoda, Jana; Yang, Litao; Buh Gasparic, Meti; Blejec, Andrej; Fouilloux, Stephane; De Loose, Marc; Taverniers, Isabel

    2010-03-01

    A reliable PCR reference assay for relative genetically modified organism (GMO) quantification must be specific for the target taxon and amplify uniformly along the commercialised varieties within the considered taxon. Different reference assays for maize (Zea mays L.) are used in official methods for GMO quantification. In this study, we evaluated the reliability of eight existing maize reference assays, four of which are used in combination with an event-specific polymerase chain reaction (PCR) assay validated and published by the Community Reference Laboratory (CRL). We analysed the nucleotide sequence variation in the target genomic regions in a broad range of transgenic and conventional varieties and lines: MON 810 varieties cultivated in Spain and conventional varieties from various geographical origins and breeding history. In addition, the reliability of the assays was evaluated based on their PCR amplification performance. A single base pair substitution, corresponding to a single nucleotide polymorphism (SNP) reported in an earlier study, was observed in the forward primer of one of the studied alcohol dehydrogenase 1 (Adh1) (70) assays in a large number of varieties. The SNP presence is consistent with a poor PCR performance observed for this assay along the tested varieties. The obtained data show that the Adh1 (70) assay used in the official CRL NK603 assay is unreliable. Based on our results from both the nucleotide stability study and the PCR performance test, we can conclude that the Adh1 (136) reference assay (T25 and Bt11 assays) as well as the tested high mobility group protein gene assay, which also form parts of CRL methods for quantification, are highly reliable. Despite the observed uniformity in the nucleotide sequence of the invertase gene assay, the PCR performance test reveals that this target sequence might occur in more than one copy. Finally, although currently not forming a part of official quantification methods, zein and SSIIb assays are found to be highly reliable in terms of nucleotide stability and PCR performance and are proposed as good alternative targets for a reference assay for maize.

  19. Evaluation of a Real-Time PCR Kit for Detecting Escherichia coli O157 in Bovine Fecal Samples

    PubMed Central

    Bono, James L.; Keen, James E.; Miller, Laura C.; Fox, James M.; Chitko-McKown, Carol G.; Heaton, Michael P.; Laegreid, William W.

    2004-01-01

    A commercially available real-time, rapid PCR test was evaluated for its ability to detect Escherichia coli O157. Both the sensitivity and specificity of the assay were 99% for isolates in pure culture. The assay detected 1 CFU of E. coli O157:H7 g−1 in artificially inoculated bovine feces following enrichment. PMID:15006817

  20. Islet Assessment for Transplantation

    PubMed Central

    Papas, Klearchos K.; Suszynski, Thomas M.; Colton, Clark. K.

    2010-01-01

    Purpose of review There is a critical need for meaningful viability and potency assays that characterize islet preparations for release prior to clinical islet cell transplantation (ICT). Development, testing, and validation of such assays have been the subject of intense investigation for the past decade. These efforts are reviewed, highlighting the most recent results while focusing on the most promising assays. Recent Findings Assays based on membrane integrity do not reflect true viability when applied to either intact islets or dispersed islet cells. Assays requiring disaggregation of intact islets into individual cells for assessment introduce additional problems of cell damage and loss. Assays evaluating mitochondrial function, specifically mitochondrial membrane potential, bioenergetic status, and cellular oxygen consumption rate (OCR), especially when conducted with intact islets, appear most promising in evaluating their quality prior to ICT. Prospective, quantitative assays based on measurements of OCR with intact islets have been developed, validated and their results correlated with transplant outcomes in the diabetic nude mouse bioassay. Conclusion More sensitive and reliable islet viability and potency tests have been recently developed and tested. Those evaluating mitochondrial function are most promising, correlate with transplant outcomes in mice, and are currently being evaluated in the clinical setting. PMID:19812494

  1. Evaluation of a colorimetric reagent strip assay for urine specific gravity.

    PubMed

    Kirschbaum, B B

    1983-06-01

    N-Multistix SG provides a convenient colorimetric assay for the determination of the specific gravity (sp. gr.) of freshly voided urine. When compared with results obtained by standard hydrometry, the colorimetric assay sp. gr. was observed to decrease by as much as 0.010 units as urine pH increased from 5 to 7. Moderate levels of proteinuria that did not alter hydrometer readings effectively raised the colorimetric sp. gr. by 0.005-0.010 units. The colorimetric assay was almost completely insensitive to clinically encountered concentrations of glucose and urea but responded appropriately to monovalent salts. The magnitude of these observed discrepancies places serious limitations on the value of the colorimetric sp. gr. measurement.

  2. HybProbes-based real-time PCR assay for specific identification of Streptomyces scabies and Streptomyces europaeiscabiei, the potato common scab pathogens.

    PubMed

    Xu, R; Falardeau, J; Avis, T J; Tambong, J T

    2016-02-01

    The aim of this study was to develop and validate a HybProbes-based real-time PCR assay targeting the trpB gene for specific identification of Streptomyces scabies and Streptomyces europaeiscabiei. Four primer pairs and a fluorescent probe were designed and evaluated for specificity in identifying S. scabies and Streptomyces europaeiscabiei, the potato common scab pathogens. The specificity of the HybProbes-based real-time PCR assay was evaluated using 46 bacterial strains, 23 Streptomyces strains and 23 non-Streptomyces bacterial species. Specific and strong fluorescence signals were detected from all nine strains of S. scabies and Streptomyces europaeiscabiei. No fluorescence signal was detected from 14 strains of other Streptomyces species and all non-Streptomyces strains. The identification was corroborated by the melting curve analysis that was performed immediately after the amplification step. Eight of the nine S. scabies and S. europaeiscabiei strains exhibited a unique melting peak, at Tm of 69·1°C while one strain, Warba-6, had a melt peak at Tm of 65·4°C. This difference in Tm peaks could be attributed to a guanine to cytosine mutation in strain Warba-6 at the region spanning the donor HybProbe. The reported HybProbes assay provides a more specific tool for accurate identification of S. scabies and S. europaeiscabiei strains. This study reports a novel assay based on HybProbes chemistry for rapid and accurate identification of the potato common scab pathogens. Since the HybProbes chemistry requires two probes for positive identification, the assay is considered to be more specific than conventional PCR or TaqMan real-time PCR. The developed assay would be a useful tool with great potential in early diagnosis and detection of common scab pathogens of potatoes in infected plants or for surveillance of potatoes grown in soil environment. © 2015 Her Majesty the Queen in Right of Canada © 2015 The Society for Applied Microbiology.

  3. Development of a loop-mediated isothermal amplification assay for rapid detection of Burkholderia mallei.

    PubMed

    Mirzai, S; Safi, S; Mossavari, N; Afshar, D; Bolourchian, M

    2016-08-31

    The present study was conducted to establish a Loop-mediated isothermal amplification (LAMP) technique for the rapid detection of B. mallei the etiologic agent of glanders, a highly contagious disease of equines. A set of six specific primers targeting integrase gene cluster were designed for the LAMP test. The reaction was optimized using different temperatures and time intervals. The specificity of the assay was evaluated using DNA from B.pseudomallei and Pseudomonas aeruginosa. The LAMP products were analyzed both visually and under UV light after electrophoresis. The optimized conditions were found to be at 63ºC for 60 min. The assay showed high specificity and sensitivity. It was concluded that the established LAMP assay is a rapid, sensitive and practical tool for detection of B. mallei and early diagnosis of glanders.

  4. Diagnostic value of serum galactomannan, (1-3)-β-D-glucan, and Aspergillus fumigatus-specific IgA and IgG assays for invasive pulmonary aspergillosis in non-neutropenic patients.

    PubMed

    Dobias, R; Jaworska, P; Tomaskova, H; Kanova, M; Lyskova, P; Vrba, Z; Holub, C; Svobodová, L; Hamal, P; Raska, M

    2018-03-25

    Detection of serum galactomannan (GM) and (1-3)-β-D-glucan (BG) is considered useful for non-culture diagnosis of invasive pulmonary aspergillosis (IPA) in neutropenic patients. Only few studies evaluated these seromarkers in non-neutropenic patients suspected of having IPA. The aim of this study was to evaluate both tests together with the Aspergillus fumigatus-specific serum IgG and IgA (IgAG) test for serological IPA diagnosis in non-neutropenic patients.Sera from 87 patients suspected of having IPA were retrospectively analyzed. Patients were categorized into groups of proven IPA (n=10), putative IPA (n=31), and non-IPA colonization (n=46). When the GM, BG, and IgAG assays were used for patients included in the study, the sensitivity/specificity / positive predictive value (PPV) / negative predictive value (NPV) were 48.8%/91.3%/83.3%/66.7%, 82.9%/73.9%/73.9%/82.9%, and 75.6%/95.7%/93.9%/81.5%, respectively. Thus, the highest specificity and PPV were confirmed for the IgAG assay. Improvements in the sensitivity and NPV were achieved by "at least one positive" analysis with the GM and BG assays, with the sensitivity/specificity/PPV/NPV values being 85.0%/69.6%/71.4%/84.2%. Nevertheless, the highest sensitivity and NPV were achieved by the "at least one positive" analysis combining the GM, BG, and IgAG tests (97.6% and 96.8%, respectively).The involvement of the IgAG assay could improve IPA diagnosis in non-neutropenic patients by increasing the sensitivity and NPV when combined with the GM or BG assays. Further improvement was achieved by combining the GM, BG, and IgAG assays using the "at least one positive test" strategy, especially if doubt exists. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Assessment of the neutrophilic antibody-dependent respiratory burst (ADRB) response to Plasmodium falciparum

    PubMed Central

    Kapelski, Stephanie; Klockenbring, Torsten; Fischer, Rainer; Barth, Stefan; Fendel, Rolf

    2014-01-01

    Semi-immunity against Pf malaria is based on a combination of cellular and humoral immune responses. PMNs and IgGs are considered important components of this process, but the underlying mechanisms are unclear. We investigated the neutrophilic ADRB by analyzing the production of ROS in response to Pf antigen-specific IgGs bound to solid-phase immobilized antigens (sADRB) or whole merozoites (mADRB). We found that the PMN stimulations in each assay were based on different underlying mechanisms, demonstrating the importance of the assay set-up for the evaluation of antibody-triggered PMN responses. In the sADRB assay, ROS were produced externally, and by specific blocking of CD32(a)/FcγRII(a), the immediate neutrophilic response was abolished, whereas the removal of CD16(b)/FcγRIII(b) had no substantial effect. The key role of CD32(a) was confirmed using CD16(b)-deficient PMNs, in which similar changes of neutrophilic ADRB profiles were recorded after treatment. In the mADRB assay, ROS were produced almost exclusively within the cell, suggesting that the underlying mechanism was phagocytosis. This was confirmed using an additional phagocytosis assay, in which PMNs specifically ingested merozoites opsonized with Ghanaian plasma IgGs, seven times more often than merozoites opsonized with European plasma IgGs (P<0.001). Our data show that assay set-ups used to evaluate the responses of PMNs and perhaps other effector cells must be chosen carefully to evaluate the appropriate cellular responses. Our robust, stable, and well-characterized methods could therefore be useful in malaria vaccine studies to analyze the antimalarial effector function of antibodies. PMID:25118179

  6. Evaluation of a Real-Time PCR Test for the Detection and Discrimination of Theileria Species in the African Buffalo (Syncerus caffer)

    PubMed Central

    Chaisi, Mamohale E.; Janssens, Michiel E.; Vermeiren, Lieve; Oosthuizen, Marinda C.; Collins, Nicola E.; Geysen, Dirk

    2013-01-01

    A quantitative real-time PCR (qPCR) assay based on the cox III gene was evaluated for the simultaneous detection and discrimination of Theileria species in buffalo and cattle blood samples from South Africa and Mozambique using melting curve analysis. The results obtained were compared to those of the reverse line blot (RLB) hybridization assay for the simultaneous detection and differentiation of Theileria spp. in mixed infections, and to the 18S rRNA qPCR assay results for the specific detection of Theileria parva. Theileria parva, Theileria sp. (buffalo), Theileria taurotragi, Theileria buffeli and Theileria mutans were detected by the cox III assay. Theileria velifera was not detected from any of the samples analysed. Seventeen percent of the samples had non-species specific melting peaks and 4.5% of the samples were negative or below the detection limit of the assay. The cox III assay identified more T. parva and Theileria sp. (buffalo) positive samples than the RLB assay, and also detected more T. parva infections than the 18S assay. However, only a small number of samples were positive for the benign Theileria spp. To our knowledge T. taurotragi has never been identified from the African buffalo, its identification in some samples by the qPCR assay was unexpected. Because of these discrepancies in the results, cox III qPCR products were cloned and sequenced. Sequence analysis indicated extensive inter- and intra-species variations in the probe target regions of the cox III gene sequences of the benign Theileria spp. and therefore explains their low detection. The cox III assay is specific for the detection of T. parva infections in cattle and buffalo. Sequence data generated from this study can be used for the development of a more inclusive assay for detection and differentiation of all variants of the mildly pathogenic and benign Theileria spp. of buffalo and cattle. PMID:24146782

  7. Evaluation of a real-time PCR test for the detection and discrimination of theileria species in the African buffalo (Syncerus caffer).

    PubMed

    Chaisi, Mamohale E; Janssens, Michiel E; Vermeiren, Lieve; Oosthuizen, Marinda C; Collins, Nicola E; Geysen, Dirk

    2013-01-01

    A quantitative real-time PCR (qPCR) assay based on the cox III gene was evaluated for the simultaneous detection and discrimination of Theileria species in buffalo and cattle blood samples from South Africa and Mozambique using melting curve analysis. The results obtained were compared to those of the reverse line blot (RLB) hybridization assay for the simultaneous detection and differentiation of Theileria spp. in mixed infections, and to the 18S rRNA qPCR assay results for the specific detection of Theileria parva. Theileria parva, Theileria sp. (buffalo), Theileria taurotragi, Theileria buffeli and Theileria mutans were detected by the cox III assay. Theileria velifera was not detected from any of the samples analysed. Seventeen percent of the samples had non-species specific melting peaks and 4.5% of the samples were negative or below the detection limit of the assay. The cox III assay identified more T. parva and Theileria sp. (buffalo) positive samples than the RLB assay, and also detected more T. parva infections than the 18S assay. However, only a small number of samples were positive for the benign Theileria spp. To our knowledge T. taurotragi has never been identified from the African buffalo, its identification in some samples by the qPCR assay was unexpected. Because of these discrepancies in the results, cox III qPCR products were cloned and sequenced. Sequence analysis indicated extensive inter- and intra-species variations in the probe target regions of the cox III gene sequences of the benign Theileria spp. and therefore explains their low detection. The cox III assay is specific for the detection of T. parva infections in cattle and buffalo. Sequence data generated from this study can be used for the development of a more inclusive assay for detection and differentiation of all variants of the mildly pathogenic and benign Theileria spp. of buffalo and cattle.

  8. Strain-specific reverse transcriptase PCR assay: means to distinguish candidate vaccine from wild-type strains of respiratory syncytial virus.

    PubMed Central

    Zheng, H; Peret, T C; Randolph, V B; Crowley, J C; Anderson, L J

    1996-01-01

    Candidate live-virus vaccines for respiratory syncytial virus are being developed and are beginning to be evaluated in clinical trials. To distinguish candidate vaccine strains from wild-type strains isolated during these trials, we developed PCR assays specific to two sets of candidate vaccine strains. The two sets were a group A strain (3A), its three attenuated, temperature-sensitive variant strains, a group B strain (2B), and its four attenuated, temperature-sensitive variant strains. The PCR assays were evaluated by testing 18 group A wild-type strains, the 3A strains, 9 group B wild-type strains, and the 2B strains. PCR specific to group A wild-type strains amplified only group A wild-type strains, and 3A-specific PCR amplified only 3A strains. PCR specific to group B wild-type strains amplified all group A and group B strains but gave a 688-bp product for group B wild-type strains, a 279-bp product for 2B strains, a 547-bp product for all group A strains, and an additional 688-bp product for some group A strains, including 3A strains. These types of PCR assays can, in conjunction with other methods, be used to efficiently distinguish candidate vaccine strains from other respiratory syncytial virus strains. PMID:8789010

  9. Development and evaluation of flow through assay for detection of antibodies against porcine cysticercosis.

    PubMed

    Sreedevi, C; Hafeez, Md; Subramanyam, K V; Anand Kumar, P; Chengalva Rayulu, V

    2011-04-01

    A flow through assay (FTA) was developed on cellulose acetate membrane for the serodiagnosis of porcine cysticercosis using cyst fluid (CFA) and whole cyst antigens (WCA) of Taenia solium metacestode. The assay consisted of antigen of T. solium metacestode coated onto membrane, mounted on a flow-through test device to provide assay capture matrix. The optimum concentration of coating antigen was 250 ng. The protein A colloidal gold conjugate served as antigen-antibody detecting reagent. A total of 225 serum samples were tested using two antigens. Results were better with CFA (96.0% sensitivity; 96.0% specificity) compared to WCA (92.0% sensitivity; 96.0% specificity). The test was also compared with enzyme-linked immunosorbent assay. The ELISA showed 96 per cent sensitivity with both the antigens whereas; the specificity was 96 and 92 per cent with CFA and WCA respectively. The sensitivity and specificity of flow through assay agrees closely with those of the ELISA. The cross-reaction was observed in one out of eight hydatidosis positive pigs (12.5%) with CFA by both the assays. The highest diagnostic accuracy (96%) was obtained with CFA-FTA and CFA-ELISA. For its high sensitivity and sporadic cross-reactions, CFA-FTA appears to be suitable for practical use at field level without instrumentation.

  10. Comparison of the Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay with the original standard assay and cell culture.

    PubMed

    Chan, E L; Brandt, K; Stoneham, H; Horsman, G

    1997-08-01

    The new Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay was evaluated by comparison with the original standard assay and cell culture. A total of 853 paired male and female genital tract specimens was tested with both Sanofi Chlamydia Microplate EIA shortened and standard assays and the results were compared with those of cell culture. For confirmation, a blocking assay run in the shortened format was used. Discrepancies between the three methods were resolved by a direct fluorescent antibody (DFA) test on the EIA samples or the culture retentate, or both. After resolution of discrepant results, the standard assay had a sensitivity, specificity, positive predictive value and negative predictive value of 98.5%, 100%, 100% and 99.9%, respectively. The shortened assay results were 100%, 100%, 100% and 100%, respectively. The shortened assay takes approximately 1.5 h less time than the standard assay and this study demonstrated that they have equivalent sensitivity and specificity. The improvement in turnaround time enables results to be reported on the same day.

  11. Comparison of the Commercial QuantiFERON-CMV and Overlapping Peptide-based ELISPOT Assays for Predicting CMV Infection in Kidney Transplant Recipients.

    PubMed

    Kwon, Ji-Soo; Kim, Taeeun; Kim, Sun-Mi; Sung, Heungsup; Shin, Sung; Kim, Young Hoon; Shin, Eui-Cheol; Kim, Sung-Han; Han, Duck Jong

    2017-10-01

    Cytomegalovirus (CMV) is one of the most important opportunistic infections in transplant recipients. Tests for CMV-specific T cell responses have been proposed to change the current risk stratification strategy using CMV assays. We evaluated the usefulness of pre-transplant CMV-specific T cell assays in kidney transplant (KT) candidates for predicting the development of CMV infection after transplantation comparing the results of the overlapping peptides (OLPs)-based enzyme-linked immunospot (ELISPOT) assay and the commercial QuantiFERON-CMV assay. We prospectively enrolled all cases of KT over a 5-month period, except donor CMV-seropositive and recipient seronegative transplants that are at highest risk of CMV infection. All the patients underwent QuantiFERON-CMV, CMV OLPs-based pp65, and immediate-early 1 (IE-1)-specific ELISPOT assays before transplantation. The primary outcome was the incidence of CMV infection at 6 months after transplant. The total of 47 KT recipients consisted of 45 living-donor KTs and 2 deceased-donor KTs. There was no association between positive QuantiFERON-CMV results and CMV infection. However, 10 of 34 patients with phosphoprotein 65 (pp65)- or IE-1-specific ELISPOT results higher than cut-off value developed CMV infections compared with none of 13 patients with results lower than cut-off value developed CMV. The OLPs-based ELISPOT assays are more useful than the QuantiFERON-CMV assay for predicting CMV infection. Patients with higher CMV-specific T cell immunity at baseline appear to be more likely to develop CMV infections after KT, suggesting that the abrupt decline in CMV-specific T cell responses after immunosuppression, or high CMV-specific T cell responses due to frequent CMV activation before KT, may promote CMV infection.

  12. Comparison of the Commercial QuantiFERON-CMV and Overlapping Peptide-based ELISPOT Assays for Predicting CMV Infection in Kidney Transplant Recipients

    PubMed Central

    Kwon, Ji-Soo; Kim, Taeeun; Kim, Sun-Mi; Sung, Heungsup; Shin, Sung; Kim, Young Hoon; Han, Duck Jong

    2017-01-01

    Cytomegalovirus (CMV) is one of the most important opportunistic infections in transplant recipients. Tests for CMV-specific T cell responses have been proposed to change the current risk stratification strategy using CMV assays. We evaluated the usefulness of pre-transplant CMV-specific T cell assays in kidney transplant (KT) candidates for predicting the development of CMV infection after transplantation comparing the results of the overlapping peptides (OLPs)-based enzyme-linked immunospot (ELISPOT) assay and the commercial QuantiFERON-CMV assay. We prospectively enrolled all cases of KT over a 5-month period, except donor CMV-seropositive and recipient seronegative transplants that are at highest risk of CMV infection. All the patients underwent QuantiFERON-CMV, CMV OLPs-based pp65, and immediate-early 1 (IE-1)-specific ELISPOT assays before transplantation. The primary outcome was the incidence of CMV infection at 6 months after transplant. The total of 47 KT recipients consisted of 45 living-donor KTs and 2 deceased-donor KTs. There was no association between positive QuantiFERON-CMV results and CMV infection. However, 10 of 34 patients with phosphoprotein 65 (pp65)- or IE-1-specific ELISPOT results higher than cut-off value developed CMV infections compared with none of 13 patients with results lower than cut-off value developed CMV. The OLPs-based ELISPOT assays are more useful than the QuantiFERON-CMV assay for predicting CMV infection. Patients with higher CMV-specific T cell immunity at baseline appear to be more likely to develop CMV infections after KT, suggesting that the abrupt decline in CMV-specific T cell responses after immunosuppression, or high CMV-specific T cell responses due to frequent CMV activation before KT, may promote CMV infection. PMID:29093653

  13. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.

    PubMed

    Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A

    1993-01-01

    The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.

  14. Comparison of fifteen commercial assays for detecting Varicella Zoster virus IgG with reference to a time resolved fluorescence immunoassay (TRFIA) and the performance of two commercial assays for screening sera from immunocompromised individuals.

    PubMed

    Chris Maple, P A; Gunn, Annabel; Sellwood, Jane; Brown, David W G; Gray, Jim J

    2009-02-01

    The performance of fifteen, commercially available, VZV IgG assays and an "in house" indirect immunofluorescence (IF) assay has been compared to a reference VZV IgG time resolved immunofluorescence assay (VZV TRFIA). A panel of 273 VZV TRFIA IgG positive serum samples and 136 VZV TRFIA IgG susceptible sera, collected from a number of UK hospitals was used. Irrespective of the interpretation of equivocal results the most sensitive assays were Dade Behring EIA (97.4%), "in house" IF (95.2%), Human EIA (92.3%) and Becton Dickinson latex agglutination (94.1%). The least sensitive assays were Virion EIA (69.6%), Diesse EIA (68.9%) and Diasys EIA (68.5%). The least sensitive (<70%) assays all had >99.0% specificity whereas the most sensitive assays had lower specificities; for example, Dade Behring EIA had a specificity of 69.9% when equivocals were treated as VZV IgG negative. For some assays e.g. Dade Behring EIA there were major discrepancies between our findings and those reported by the manufacturer which may reflect the constitution of the panel(s) of sera used for evaluation or the reference method adopted or the choice of cut-off criteria (particularly relevant to our findings for the Behring EIA). Care must be taken to choose an assay with high specificity in order to accurately assess the need for vaccination or immunoprophylaxis; however, high sensitivity is preferable to prevent inappropriate and expensive treatment.

  15. Bench-top validation testing of selected immunological and molecular Renibacterium salmoninarum diagnostic assays by comparison with quantitative bacteriological culture

    USGS Publications Warehouse

    Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.

    2013-01-01

    No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.

  16. Development and Evaluation of a Blocking Enzyme-Linked Immunosorbent Assay and Virus Neutralization Assay To Detect Antibodies to Viral Hemorrhagic Septicemia Virus

    PubMed Central

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV. PMID:24429071

  17. Molecular Detection of 10 of the Most Unwanted Alien Forest Pathogens in Canada Using Real-Time PCR

    PubMed Central

    Lamarche, Josyanne; Potvin, Amélie; Pelletier, Gervais; Stewart, Don; Feau, Nicolas; Alayon, Dario I. O.; Dale, Angela L.; Coelho, Aaron; Uzunovic, Adnan; Bilodeau, Guillaume J.; Brière, Stephan C.; Hamelin, Richard C.; Tanguay, Philippe

    2015-01-01

    Invasive alien tree pathogens can cause significant economic losses as well as large-scale damage to natural ecosystems. Early detection to prevent their establishment and spread is an important approach used by several national plant protection organizations (NPPOs). Molecular detection tools targeting 10 of the most unwanted alien forest pathogens in Canada were developed as part of the TAIGA project (http://taigaforesthealth.com/). Forest pathogens were selected following an independent prioritization. Specific TaqMan real-time PCR detection assays were designed to function under homogeneous conditions so that they may be used in 96- or 384-well plate format arrays for high-throughput testing of large numbers of samples against multiple targets. Assays were validated for 1) specificity, 2) sensitivity, 3) precision, and 4) robustness on environmental samples. All assays were highly specific when evaluated against a panel of pure cultures of target and phylogenetically closely-related species. Sensitivity, evaluated by assessing the limit of detection (with a threshold of 95% of positive samples), was found to be between one and ten target gene region copies. Precision or repeatability of each assay revealed a mean coefficient of variation of 3.4%. All assays successfully allowed detection of target pathogen on positive environmental samples, without any non-specific amplification. These molecular detection tools will allow for rapid and reliable detection of 10 of the most unwanted alien forest pathogens in Canada. PMID:26274489

  18. Evaluation of qPCR-Based Assays for Leprosy Diagnosis Directly in Clinical Specimens

    PubMed Central

    Sarno, Euzenir Nunes; Moraes, Milton Ozório

    2011-01-01

    The increased reliability and efficiency of the quantitative polymerase chain reaction (qPCR) makes it a promising tool for performing large-scale screening for infectious disease among high-risk individuals. To date, no study has evaluated the specificity and sensitivity of different qPCR assays for leprosy diagnosis using a range of clinical samples that could bias molecular results such as difficult-to-diagnose cases. In this study, qPCR assays amplifying different M. leprae gene targets, sodA, 16S rRNA, RLEP and Ag 85B were compared for leprosy differential diagnosis. qPCR assays were performed on frozen skin biopsy samples from a total of 62 patients: 21 untreated multibacillary (MB), 26 untreated paucibacillary (PB) leprosy patients, as well as 10 patients suffering from other dermatological diseases and 5 healthy donors. To develop standardized protocols and to overcome the bias resulted from using chromosome count cutoffs arbitrarily defined for different assays, decision tree classifiers were used to estimate optimum cutoffs and to evaluate the assays. As a result, we found a decreasing sensitivity for Ag 85B (66.1%), 16S rRNA (62.9%), and sodA (59.7%) optimized assay classifiers, but with similar maximum specificity for leprosy diagnosis. Conversely, the RLEP assay showed to be the most sensitive (87.1%). Moreover, RLEP assay was positive for 3 samples of patients originally not diagnosed as having leprosy, but these patients developed leprosy 5–10 years after the collection of the biopsy. In addition, 4 other samples of patients clinically classified as non-leprosy presented detectable chromosome counts in their samples by the RLEP assay suggesting that those patients either had leprosy that was misdiagnosed or a subclinical state of leprosy. Overall, these results are encouraging and suggest that RLEP assay could be useful as a sensitive diagnostic test to detect M. leprae infection before major clinical manifestations. PMID:22022631

  19. Evaluation of a cow-side milk progesterone assay and assessment of the positive predictive value of oestrus diagnosis by dairy farmers in New South Wales.

    PubMed

    Ingenhoff, L; Hall, E; House, J K

    2016-12-01

    The three objectives of this study were to determine the positive predictive value (PPV) of oestrus diagnosis (heat detection accuracy) by dairy farmers, calculate the diagnostic sensitivity and specificity of the P4 Rapid milk progesterone assay for detecting a corpus luteum and evaluate the economics of using a cow-side milk progesterone assay designed to aid oestrus diagnosis. Milk samples were collected from 752 cows diagnosed in oestrus by farm personnel on 14 dairy farms. Samples were tested using the P4 Rapid milk progesterone assay to estimate the PPV of oestrus diagnosis at each farm and a crude pooled mean of PPV of oestrus diagnosis across all farms. A further 156 milk samples were collected from cows with luteal tissue status determined by transrectal ultrasound and tested by the P4 Rapid assay to enable calculation of the sensitivity and specificity of the P4 Rapid assay. For pooled farm samples, the PPV was 97.0%, with a range between farms of 88.9-100%. Sensitivity of the P4 Rapid milk progesterone assay for detecting a corpus luteum was 90.1% and specificity was 98.7%. Misclassification of oestrus in cows previously identified as pregnant was the most common cause of false-positive oestrus diagnoses by farm personnel. Routine testing of milk progesterone in all cows diagnosed in oestrus is not economically justified and may even slightly reduce submission rates; conversely, strategic use of cow-side milk progesterone assays can improve herd reproductive performance by facilitating decisions on whether to rebreed cows previously diagnosed as pregnant. © 2016 Australian Veterinary Association.

  20. [Quantitative fluorogenic real-time PCR assay for respiratory syncytial virus detection].

    PubMed

    Zhang, Qi-wei; You, Shang-you; Sun, Ji-min; Wu, Qi; Yu, Chun-hua; Zhang, Chu-yu

    2005-07-01

    To Establish a rapid and objective quantitative fluorogenic real-time PCR assay for early detection of human respiratory syncytial virus (hRSV). Two pairs of primers and one TaqMan Fluorogenic probe that are specific for the recognition of the most conservative N gene of hRSV for virus detection with LighCycler PCR in 93 nasopharyngeal secretion specimens collected from infants and young children. The assay was compared with virus isolation, routine PCR, nested PCR, and enzyme-linked immunosorbent assay (ELISA). This TaqMan assay had a sensitivity of 1 x 10(2) cDNA copies/microl with a dynamic range between 1 x 10(2) and 1 x 10(7) cDNA copies/microl, which was the same as that of nested PCR, but 10 times more sensitive than routine PCR. The specificity of the assay was evaluated by comparing hRSV with polivirus type 1, coxsackie virus type 2, influenza A, influenza B and adenovirus type 7. A PCR product of the expected size (195 bp) was produced and fluorescence signal detected for hRSV, but not for any of the other viruses. The results in LightCycler and Rotor-Gene instrument were consistent. Forty-four specimens (43.9%) were hRSV-positive with this assay and 4 (4/93,4.3%) were hRSV-positive with ELISA, showing rather low correlation between the two methods. No visible relation was found between the concentration of hRSV RNA and severity of the disease. This assay is rapid, sensitive, specific and quantitative, and has the potential of wide application for early diagnosis of hRSV infection and evaluation of the therapeutic effect.

  1. Specific and quantitative detection of human polyomaviruses BKV, JCV, and SV40 by real time PCR.

    PubMed

    McNees, Adrienne L; White, Zoe S; Zanwar, Preeti; Vilchez, Regis A; Butel, Janet S

    2005-09-01

    The polyomaviruses that infect humans, BK virus (BKV), JC virus (JCV), and simian virus 40 (SV40), typically establish subclinical persistent infections. However, reactivation of these viruses in immunocompromised hosts is associated with renal nephropathy and hemorrhagic cystitis (HC) caused by BKV and with progressive multifocal leukoencephalopathy (PML) caused by JCV. Additionally, SV40 is associated with several types of human cancers including primary brain and bone cancers, mesotheliomas, and non-Hodgkin's lymphoma. Advancements in detection of these viruses may contribute to improved diagnosis and treatment of affected patients. To develop sensitive and specific real time quantitative polymerase chain reaction (RQ-PCR) assays for the detection of T-antigen DNA sequences of the human polyomaviruses BKV, JCV, and SV40 using the ABI Prism 7000 Sequence Detection System. Assays for absolute quantification of the viral T-ag sequences were designed and the sensitivity and specificity were evaluated. A quantitative assay to measure the single copy human RNAse P gene was also developed and evaluated in order to normalize viral gene copy numbers to cell numbers. Quantification of the target genes is sensitive and specific over a 7 log dynamic range. Ten copies each of the viral and cellular genes are reproducibly and accurately detected. The sensitivity of detection of the RQ-PCR assays is increased 10- to 100-fold compared to conventional PCR and agarose gel protocols. The primers and probes used to detect the viral genes are specific for each virus and there is no cross reactivity within the dynamic range of the standard dilutions. The sensitivity of detection for these assays is not reduced in human cellular extracts; however, different DNA extraction protocols may affect quantification. These assays provide a technique for rapid and specific quantification of polyomavirus genomes per cell in human samples.

  2. Comparison of Two Assays for Molecular Determination of Rifampin Resistance in Clinical Samples from Patients with Buruli Ulcer Disease

    PubMed Central

    Phillips, Richard Odame; Badziklou, Kossi; Piten, Ebekalisai; Maman, Issaka; Sarfo, Fred Stephen; Huber, Kristina Lydia; Rhomberg, Agata; Symank, Dominik; Wagner, Magdalena; Wiedemann, Franz; Nitschke, Jörg; Banla Kere, Abiba; Herbinger, Karl-Heinz; Adjei, Ohene; Löscher, Thomas; Bretzel, Gisela

    2014-01-01

    This study evaluates a novel assay for detecting rifampin resistance in clinical Mycobacterium ulcerans isolates. Although highly susceptible for PCR inhibitors in 50% of the samples tested, the assay was 100% M. ulcerans specific and yielded >98% analyzable sequences with a lower limit of detection of 100 to 200 copies of the target sequence. PMID:24478404

  3. A molecular-beacon-based asymmetric PCR assay for easy visualization of amplicons in the diagnosis of trichomoniasis.

    PubMed

    Sonkar, Subash C; Sachdev, Divya; Mishra, Prashant K; Kumar, Anita; Mittal, Pratima; Saluja, Daman

    2016-12-15

    The currently available nucleic acid amplification tests (NAATs) for trichomoniasis are accurate, quick and confirmative with superior sensitivity than traditional culture-based microbiology assays. However, these assays are associated with problems of carry over contamination, false positive results, requirement of technical expertise for performance and detection of end product. Hence, a diagnostic assay with easy visualization of the amplified product will be profitable. An in-house, rapid, sensitive, specific molecular-beacon-based PCR assay, using primers against pfoB gene of Trichomonas vaginalis, was developed and evaluated using dry ectocervical swabs (n=392) from symptomatic females with vaginal discharge. Total DNA was isolated and used as template for the PCR assays. The performance and reproducibility of PCR assay was evaluated by composite reference standard (CRS). For easy visualization of the amplified product, molecular-beacon was designed and amplicons were visualized directly using fluorescent handheld dark reader or by Micro-Plate Reader. Molecular-beacons are single-stranded hairpin shaped nucleic acid probes composed of a stem, with fluorophore/quencher pair and a loop region complementary to the desired DNA. The beacon-based PCR assay designed in the present study is highly specific as confirmed by competition experiments and extremely sensitive with detection limit of 20fg of genomic DNA (3-4 pathogens). The minimum infrastructure requirement and ease to perform the assay makes this method highly useful for resource poor countries for better disease management. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Development of Electrochemiluminescent Serology Assays to Measure the Humoral Response to Antigens of Respiratory Syncytial Virus.

    PubMed

    Maifeld, Sarah V; Ro, Bodrey; Mok, Hoyin; Chu, Marla; Yu, Li; Yamagata, Ryan; Leonardson, Tansy; Chio, Vera; Parhy, Bandita; Park, Samuel; Carlson, Marcia; Machhi, Shushil; Ulbrandt, Nancy; Falsey, Ann R; Walsh, Edward E; Wang, C Kathy; Esser, Mark T; Zuo, Fengrong

    2016-01-01

    Sensitive and precise serology assays are needed to measure the humoral response to antigens of respiratory syncytial virus (RSV) following natural infection or vaccination. We developed and evaluated a collection of electrochemiluminescent (ECL) serology assays using four RSV antigens (F, N, Ga and Gb). To assess the merits of ECL technology, the four ECL serology assays were evaluated using a well-characterized "gold standard" panel of acute and convalescent serum samples from fifty-nine RSV-positive and thirty RSV-negative elderly subjects (≥65 years old). The combined results from the four ECL assays demonstrated good concordance to the "gold standard" diagnosis, reaching 95% diagnostic sensitivity and 100% diagnostic specificity. Additionally, a combination of ECL assays provided higher diagnostic sensitivity than a commercially available diagnostic ELISA or cell-based microneutralization assay. In summary, these data demonstrate the advantages of using ECL-based serology assays and highlight their use as a sensitive diagnostic approach to detect recent RSV infection in an elderly population.

  5. Evaluation of OXA-48 K-Se T: an immunochromatographic assay for rapid detection of OXA-48-producing Enterobacteriaceae.

    PubMed

    Fernández, Javier; Fleites, Ana; Rodcio, María Rosario; Vazquez, Fernando

    2016-05-01

    The OXA-48 K-Se T, a new immunochromatographic assay for rapid detection of OXA-48-producing Enterobacteriaceae, has been evaluated in a Spanish Hospital during a 3-month period. A collection of 100 Enterobacteriaceae including 79 isolates producing OXA-48 has been tested. Sensitivity and specificity of 100% were obtained. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Evaluation of ethanol vortex ELISA for detection of bovine tuberculosis in cattle and deer.

    PubMed

    Wadhwa, Ashutosh; Johonson, Rachel E; Eda, Keiko; Waters, W Ray; Palmer, Mitchell V; Bannantine, John P; Eda, Shigetoshi

    2014-07-04

    The use of serological assays for diagnosis of bovine tuberculosis (TB) has been intensively studied and use of specific antigens have aided in improving the diagnostic accuracy of the assays. In the present study, we report an in-house enzyme linked immunosorbent assay (ELISA), developed by using ethanol extract of Mycobacterium bovis (M. bovis). The assay, named (ethanol vortex ELISA [EVELISA]), was evaluated for detection of anti- M. bovis antibodies in the sera of cattle and white-tailed deer. By using the EVELISA, we tested sera obtained from two species of animals; cattle (n = 62 [uninfected, n = 40; naturally infected, n = 22]) and white-tailed deer (n = 41 [uninfected, n = 25; naturally infected, n = 7; experimentally infected, n = 9]). To detect species specific molecules, components in the ethanol extract were analyzed by thin layer chromatography and western blotting. Among the tested animals, 77.2% of infected cattle and 87.5% of infected deer tested positive for anti- M. bovis antibody. There were only minor false positive reactions (7.5% in cattle and 0% in deer) in uninfected animals. M. bovis -specific lipids and protein (MPB83) in the ethanol extract were detected by thin layer chromatography and western blotting, respectively. The results warrant further evaluation and validation of EVELISA for bovine TB diagnosis of traditional and alternative livestock as well as for free-ranging animal species.

  7. Synthesis and evaluation of phosphorus containing, specific CDK9/CycT1 inhibitors.

    PubMed

    Németh, Gábor; Greff, Zoltán; Sipos, Anna; Varga, Zoltán; Székely, Rita; Sebestyén, Mónika; Jászay, Zsuzsa; Béni, Szabolcs; Nemes, Zoltán; Pirat, Jean-Luc; Volle, Jean-Noël; Virieux, David; Gyuris, Ágnes; Kelemenics, Katalin; Ay, Eva; Minarovits, Janos; Szathmary, Susan; Kéri, György; Orfi, László

    2014-05-22

    Although there is a significant effort in the design of a selective CDK9/CycT1 inhibitor, no compound has been proven to be a specific inhibitor of this kinase so far. The aim of this research was to develop novel and selective phosphorus containing CDK9/CycT1 inhibitors. Molecules bearing phosphonamidate, phosphonate, and phosphinate moieties were synthesized. Prepared compounds were evaluated in an enzymatic CDK9/CycT1 assay. The most potent molecules were tested in cell-based toxicity and HIV proliferation assays. Selectivity of shortlisted compounds against CDKs and other kinases was tested. The best compound was shown to be a highly specific, ATP-competitive inhibitor of CDK9/CycT1 with antiviral activity.

  8. An in vitro evaluation of the Native American ethnomedicinal plant Eryngium yuccifolium as a treatment for snakebite envenomation

    PubMed Central

    Price, Joseph A.

    2016-01-01

    Aim: At least seven North American tribes specifically mention the use of Eryngium (typically roots) as an anti-snake venom therapy. As snake envenomation is an endemic, life-threatening medical risk, is there a scientific basis for the Native American ethnomedicine? Could this be demonstrated in an assay amenable to mechanistic evaluation and high throughput screening for later isolation and possible evaluation as a source for a lead drug? Materials and Methods: Proteases, mainly metalloproteases, are thought to be the main pathological agents in most American snake venoms. Water extracts of four plant parts of Eryngium yuccifolium were tested for enzyme inhibition in three highly sensitive in vitro protease assays, with multiple venoms. Results: Interestingly, activity was found in all plant parts, not just the roots, in the general protease assay, also in the most specific assay for collagenases, but less so for elastases where enzymatic activity was low, and against five species of American snake venoms. Inhibition spared the activity of a mammalian elastase, suggesting it has some specificity. In dose response assays, inhibitory activity in extracts of Eryngium was noticeably more effective than randomly chosen plants and comparable to some others. Conclusions: All data shown here are consistent with pharmacological inhibition of proteases in at least selected venoms of common venomous snakes by Eryngium extracts. Moreover, as the genus is widely distributed in America, the ethnological practice of using this plant as an anti-snake venom treatment is supportable, may have been common, and suggests further bioactivity and phytochemical studies are warranted. PMID:27366346

  9. Evaluation of an antibody avidity index method for detecting recent human immunodeficiency virus type 1 infection using an automated chemiluminescence immunoassay.

    PubMed

    Fernández, Gema; Manzardo, Christian; Montoliu, Alexandra; Campbell, Colin; Fernández, Gregorio; Casabona, Jordi; Miró, José Maria; Matas, Lurdes; Rivaya, Belén; González, Victoria

    2015-04-01

    Recent infection testing algorithms (RITAs) are used in public health surveillance to estimate the incidence of recently acquired HIV-1 infection. Our aims were (i) to evaluate the precision of the VITROS® Anti-HIV 1+2 automated antibody avidity assay for qualitative detection of antibodies to HIV 1+2 virus; (ii) to validate the accuracy of an automated guanidine-based antibody avidity assay to discriminate between recent and long standing infections using the VITROS 3600 platform; (iii) to compare this method with BED-CEIA assay; and (iv) to evaluate the occurrence of false recent misclassifications by the VITROS antibody avidity assay in patients with a CD4 count <200 cells/μL and in patients on combination antiretroviral therapy (cART). The VITROS® antibody avidity assay is highly reproducible. The ROC curve analysis of the accuracy of this assay, optimized for sensitivity and specificity, had an AI cut off of ≤0.51, with sensitivity and specificity values of 86.67% (95% CI: 72.51-94.46) and 86.24% (95% CI: 78.00-91.84), respectively. The agreement between VITROS antibody avidity and BED-CEIA assays was good. Misclassifications of long standing infections as recent infection occurred in 8.2% of patients with CD4 <200 cell/μL and 8.7% in patients on combination antiretroviral therapy. The VITROS antibody avidity assay is a reliable serological method to detect recent HIV-1 infections and it could be incorporated into a RITA to estimate HIV incidence. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  10. Evaluation of an Immunochromatographic Assay for Rapid Detection of Penicillin-Binding Protein 2a in Human and Animal Staphylococcus intermedius Group, Staphylococcus lugdunensis, and Staphylococcus schleiferi Clinical Isolates.

    PubMed

    Arnold, A R; Burnham, C-A D; Ford, B A; Lawhon, S D; McAllister, S K; Lonsway, D; Albrecht, V; Jerris, R C; Rasheed, J K; Limbago, B; Burd, E M; Westblade, L F

    2016-03-01

    The performance of a rapid penicillin-binding protein 2a (PBP2a) detection assay, the Alere PBP2a culture colony test, was evaluated for identification of PBP2a-mediated beta-lactam resistance in human and animal clinical isolates of Staphylococcus intermedius group, Staphylococcus lugdunensis, and Staphylococcus schleiferi. The assay was sensitive and specific, with all PBP2a-negative and PBP2a-positive strains testing negative and positive, respectively. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  11. Development and evaluation of a real-time polymerase chain reaction assay for the rapid detection of Talaromyces marneffei MP1 gene in human plasma.

    PubMed

    Hien, Ha Thuc Ai; Thanh, Tran Tan; Thu, Nguyen Thi Mai; Nguyen, Ashley; Thanh, Nguyen Tat; Lan, Nguyen Phu Huong; Simmons, Cameron; Shikuma, Cecilia; Chau, Nguyen Van Vinh; Thwaites, Guy; Le, Thuy

    2016-12-01

    Penicilliosis caused by Talaromyces marneffei is a common AIDS-defining illness in South and Southeast Asia. Diagnosis is based on culture which can take up to 14 days for identification, leading to treatment delay and increased mortality. We developed a TaqMan real-time PCR assay targeting the MP1 gene encoding an abundant cell wall protein specific to T. marneffei. The assay's performance was evaluated in MP1-containing plasmids, clinical isolates, and plasma from HIV-infected patients with and without penicilliosis. The assay consistently detected 10 copies of MP1-containing plasmids per reaction and 100 T. marneffei yeast cells per millilitre plasma. There were no amplification with seven other Penicillium species and six other HIV-associated fungal pathogens tested. The assay was evaluated in 70 patients with AIDS: 50 patients with culture-confirmed penicilliosis and 20 patients with opportunistic infections other than penicilliosis. The diagnostic sensitivity was 70.4% (19/27, 95% CI: 51.5-84.1%) and 52.2% (12/23, 95% CI: 33.0-70.8%) in plasma samples collected prior to and within 48 h of antifungal therapy respectively. The diagnostic specificity was 100% (20/20, 95% CI: 83.9-100%). This assay provides a useful tool for the rapid diagnosis of T. marneffei infection and has the potential to improve the management of patients with penicilliosis. © 2016 The Authors. Mycoses Published by Blackwell Verlag GmbH.

  12. Implementation of Novel Design Features for qPCR-Based eDNA Assessment

    PubMed Central

    Veldhoen, Nik; Hobbs, Jared; Ikonomou, Georgios; Hii, Michael; Lesperance, Mary; Helbing, Caren C.

    2016-01-01

    Environmental stewardship requires timely, accurate information related to the status of a given ecosystem and the species that occupy it. Recent advances in the application of the highly sensitive real-time quantitative polymerase chain reaction (qPCR) towards identification of constituents within environmental DNA (eDNA) now allow targeted detection of the presence of species-specific biological material within a localized geographic region. However, as with all molecular techniques predicated on the specificity and sensitivity of the PCR assay, careful validation of each eDNA qPCR assay in development must be performed both under controlled laboratory conditions and when challenged with field-derived eDNA samples. Such a step-wise approach forms the basis for incorporation of innovative qPCR design features that strengthen the implementation and interpretation of the eDNA assay. This includes empirical determination that the qPCR assay is refractory to the presence of human DNA and the use of a tripartite assay approach comprised of 1) a primer set targeting plant chloroplast that evaluates the presence of amplifiable DNA from field samples to increase confidence in a negative result, 2) an animal group primer set to increase confidence in the assay result, and 3) a species-specific primer set to assess presence of DNA from the target species. To demonstrate this methodology, we generated eDNA assays specific for the North American bullfrog (Lithobates (Rana) catesbeiana) and the Rocky Mountain tailed frog (Ascaphus montanus) and characterized each with respect to detection sensitivity and specificity with demonstrated performance in a field survey scenario. The qPCR design features presented herein address specific challenges of eDNA assays thereby increasing their interpretative power. PMID:27802293

  13. Detection of Rickettsia rickettsii, Rickettsia parkeri, and Rickettsia akari in Skin Biopsy Specimens Using a Multiplex Real-time Polymerase Chain Reaction Assay

    PubMed Central

    Denison, Amy M.; Amin, Bijal D.; Nicholson, William L.; Paddock, Christopher D.

    2015-01-01

    Background Rickettsia rickettsii, Rickettsia parkeri, and Rickettsia akari are the most common causes of spotted fever group rickettsioses indigenous to the United States. Infected patients characteristically present with a maculopapular rash, often accompanied by an inoculation eschar. Skin biopsy specimens are often obtained from these lesions for diagnostic evaluation. However, a species-specific diagnosis is achieved infrequently from pathologic specimens because immunohistochemical stains do not differentiate among the causative agents of spotted fever group rickettsiae, and existing polymerase chain reaction (PCR) assays generally target large gene segments that may be difficult or impossible to obtain from formalin-fixed tissues. Methods This work describes the development and evaluation of a multiplex real-time PCR assay for the detection of these 3 Rickettsia species from formalin-fixed, paraffin-embedded (FFPE) skin biopsy specimens. Results The multiplex PCR assay was specific at discriminating each species from FFPE controls of unrelated bacterial, viral, protozoan, and fungal pathogens that cause skin lesions, as well as other closely related spotted fever group Rickettsia species. Conclusions This multiplex real-time PCR demonstrates greater sensitivity than nested PCR assays in FFPE tissues and provides an effective method to specifically identify cases of Rocky Mountain spotted fever, rickettsialpox, and R. parkeri rickettsiosis by using skin biopsy specimens. PMID:24829214

  14. Development and systematic validation of qPCR assays for rapid and reliable differentiation of Xylella fastidiosa strains causing citrus variegated chlorosis.

    PubMed

    Li, Wenbin; Teixeira, Diva C; Hartung, John S; Huang, Qi; Duan, Yongping; Zhou, Lijuan; Chen, Jianchi; Lin, Hong; Lopes, Silvio; Ayres, A Juliano; Levy, Laurene

    2013-01-01

    The xylem-limited, Gram-negative, fastidious plant bacterium Xylella fastidiosa is the causal agent of citrus variegated chlorosis (CVC), a destructive disease affecting approximately half of the citrus plantations in the State of São Paulo, Brazil. The disease was recently found in Central America and is threatening the multi-billion U.S. citrus industry. Many strains of X. fastidiosa are pathogens or endophytes in various plants growing in the U.S., and some strains cross infect several host plants. In this study, a TaqMan-based assay targeting the 16S rDNA signature region was developed for the identification of X. fastidiosa at the species level. Another TaqMan-based assay was developed for the specific identification of the CVC strains. Both new assays have been systematically validated in comparison with the primer/probe sets from four previously published assays on one platform and under similar PCR conditions, and shown to be superior. The species specific assay detected all X. fastidiosa strains and did not amplify any other citrus pathogen or endophyte tested. The CVC-specific assay detected all CVC strains but did not amplify any non-CVC X. fastidiosa nor any other citrus pathogen or endophyte evaluated. Both sets were multiplexed with a reliable internal control assay targeting host plant DNA, and their diagnostic specificity and sensitivity remained unchanged. This internal control provides quality assurance for DNA extraction, performance of PCR reagents, platforms and operators. The limit of detection for both assays was equivalent to 2 to 10 cells of X. fastidiosa per reaction for field citrus samples. Petioles and midribs of symptomatic leaves of sweet orange harbored the highest populations of X. fastidiosa, providing the best materials for detection of the pathogen. These new species specific assay will be invaluable for molecular identification of X. fastidiosa at the species level, and the CVC specific assay will be very powerful for the specific identification of X. fastidiosa strains that cause citrus variegated chlorosis. Published by Elsevier B.V.

  15. Evaluation of carbon nanotube based copper nanoparticle composite for the efficient detection of agroviruses

    USDA-ARS?s Scientific Manuscript database

    Nanomaterials based sensors offer sensitivity and selectivity for the detection of a specific analyte-of-the-interest. Described here is a novel assay for the detection of a DNA sequence based on nanostructured carbon nanotubes/copper nanoparticles composite. This assay was modeled on strong electro...

  16. Two-colored fluorescence correlation spectroscopy screening for LC3-P62 interaction inhibitors.

    PubMed

    Tsuganezawa, Keiko; Shinohara, Yoshiyasu; Ogawa, Naoko; Tsuboi, Shun; Okada, Norihisa; Mori, Masumi; Yokoyama, Shigeyuki; Noda, Nobuo N; Inagaki, Fuyuhiko; Ohsumi, Yoshinori; Tanaka, Akiko

    2013-10-01

    The fluorescence correlation spectroscopy (FCS)-based competitive binding assay to screen for protein-protein interaction inhibitors is a highly sensitive method as compared with the fluorescent polarization assay used conventionally. However, the FCS assay identifies many false-positive compounds, which requires specifically designed orthogonal screenings. A two-colored application of the FCS-based screening was newly developed, and inhibitors of a protein-protein interaction, involving selective autophagy, were selected. We focused on the interaction of LC3 with the adaptor protein p62, because the interaction is crucial to degrade the specific target proteins recruited by p62. First, about 10,000 compounds were subjected to the FCS-based competitive assay using a TAMRA-labeled p62-derived probe, and 29 hit compounds were selected. Next, the obtained hits were evaluated by the second FCS assay, using an Alexa647-labeled p62-derived probe to remove the false-positive compounds, and six hit compounds inhibited the interaction. Finally, we tested all 29 compounds by surface plasmon resonance-based competitive binding assay to evaluate their inhibition of the LC3-p62 interaction and selected two inhibitors with IC50 values less than 2 µM. The two-colored FCS-based screening was shown to be effective to screen for protein-protein interaction inhibitors.

  17. Development of a panel of seven duplex real-time PCR assays for detecting 13 streptococcal superantigens.

    PubMed

    Yang, Peng; Peng, Xiaomin; Cui, Shujuan; Shao, Junbin; Zhu, Xuping; Zhang, Daitao; Liang, Huijie; Wang, Quanyi

    2013-07-30

    Streptococcal superantigens (SAgs) are the major virulence factors of infection in humans for group A Streptococcus (GAS) bacteria. A panel consisting of seven duplex real-time PCR assays was developed to simultaneously detect 13 streptococcal SAgs and one internal control which may be important in the control of GAS-mediated diseases. Primer and probe sequences were selected based on the highly conserved region from an alignment of nucleotide sequences of the 13 streptococcal SAgs. The reaction conditions of the duplex real-time PCR were optimized and the specificity of the duplex assays was evaluated using SAg positive strains. The limit of detection of the duplex assays was determined by using 10-fold serial dilutions of the DNA of 13 streptococcal SAgs and compared to a conventional polymerase chain reaction (PCR) method for evaluating the duplex assays sensitivity. Using the duplex assays, we were able to differentiate between 13 SAgs from Streptococcus strains and other non-Streptococcus bacteria without cross-reaction. On the other hand, the limit of detection of the duplex assays was at least one or two log dilutions lower than that of the conventional PCR. The panel was highly specific (100%) and the limit of detection of these duplex groups was at least ten times lower than that obtained by using a conventional PCR method.

  18. Evaluation of quantitative polymerase chain reaction assays targeting Mycobacterium avium, M. intracellulare, and M. avium subspecies paratuberculosis in drinking water biofilms.

    PubMed

    Chern, Eunice C; King, Dawn; Haugland, Richard; Pfaller, Stacy

    2015-03-01

    Mycobacterium avium (MA), Mycobacterium intracellulare (MI), and Mycobacterium avium subsp. paratuberculosis (MAP) are difficult to culture due to their slow growing nature. A quantitative polymerase chain reaction (qPCR) method for the rapid detection of MA, MI, and MAP can be used to provide data supporting drinking water biofilms as potential sources of human exposure. The aim of this study was to characterize two qPCR assays targeting partial 16S rRNA gene sequences of MA and MI and use these assays, along with two previously reported MAP qPCR assays (IS900 and Target 251), to investigate Mycobacterium occurrence in kitchen faucet biofilms. MA and MI qPCR assays demonstrated 100% specificity and sensitivity when evaluated against 18 non-MA complex, 76 MA, and 17 MI isolates. Both assays detected approximately 1,000 cells from a diluted cell stock inoculated on a sampling swab 100% of the time. DNA analysis by qPCR indicated that 35.3, 56.9 and 11.8% of the 51 kitchen faucet biofilm samples collected contained MA, MI, and MAP, respectively. This study introduces novel qPCR assays designed to specifically detect MA and MI in biofilm. Results support the use of qPCR as an alternative to culture for detection and enumeration of MA, MI, and MAP in microbiologically complex samples.

  19. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    PubMed

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  20. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples

    PubMed Central

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J.

    2010-01-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study. PMID:21197228

  1. Nested PCR Assay for Eight Pathogens: A Rapid Tool for Diagnosis of Bacterial Meningitis.

    PubMed

    Bhagchandani, Sharda P; Kubade, Sushant; Nikhare, Priyanka P; Manke, Sonali; Chandak, Nitin H; Kabra, Dinesh; Baheti, Neeraj N; Agrawal, Vijay S; Sarda, Pankaj; Mahajan, Parikshit; Ganjre, Ashish; Purohit, Hemant J; Singh, Lokendra; Taori, Girdhar M; Daginawala, Hatim F; Kashyap, Rajpal S

    2016-02-01

    Bacterial meningitis is a dreadful infectious disease with a high mortality and morbidity if remained undiagnosed. Traditional diagnostic methods for bacterial meningitis pose a challenge in accurate identification of pathogen, making prognosis difficult. The present study is therefore aimed to design and evaluate a specific and sensitive nested 16S rDNA genus-based polymerase chain reaction (PCR) assay using clinical cerebrospinal fluid (CSF) for rapid diagnosis of eight pathogens causing the disease. The present work was dedicated to development of an in-house genus specific 16S rDNA nested PCR covering pathogens of eight genera responsible for causing bacterial meningitis using newly designed as well as literature based primers for respective genus. A total 150 suspected meningitis CSF obtained from the patients admitted to Central India Institute of Medical Sciences (CIIMS), India during the period from August 2011 to May 2014, were used to evaluate clinical sensitivity and clinical specificity of optimized PCR assays. The analytical sensitivity and specificity of our newly designed genus-specific 16S rDNA PCR were found to be ≥92%. With such a high sensitivity and specificity, our in-house nested PCR was able to give 100% sensitivity in clinically confirmed positive cases and 100% specificity in clinically confirmed negative cases indicating its applicability in clinical diagnosis. Our in-house nested PCR system therefore can diagnose the accurate pathogen causing bacterial meningitis and therefore be useful in selecting a specific treatment line to minimize morbidity. Results are obtained within 24 h and high sensitivity makes this nested PCR assay a rapid and accurate diagnostic tool compared to traditional culture-based methods.

  2. Rapid detection of all known ebolavirus species by reverse transcription-loop-mediated isothermal amplification (RT-LAMP).

    PubMed

    Oloniniyi, Olamide K; Kurosaki, Yohei; Miyamoto, Hiroko; Takada, Ayato; Yasuda, Jiro

    2017-08-01

    Ebola virus disease (EVD), a highly virulent infectious disease caused by ebolaviruses, has a fatality rate of 25-90%. Without a licensed chemotherapeutic agent or vaccine for the treatment and prevention of EVD, control of outbreaks requires accurate and rapid diagnosis of cases. In this study, five sets of six oligonucleotide primers targeting the nucleoprotein gene were designed for specific identification of each of the five ebolavirus species using reverse transcription-loop mediated isothermal amplification (RT-LAMP) assay. The detection limits of the ebolavirus species-specific primer sets were evaluated using in vitro transcribed RNAs. The detection limit of species-specific RT-LAMP assays for Zaire ebolavirus, Sudan ebolavirus, Taï Forest ebolavirus, and Bundibugyo ebolavirus was 256 copies/reaction, while the detection limit for Reston ebolavirus was 64 copies/reaction, and the detection time for each of the RT-LAMP assays was 13.3±3.0, 19.8±4.6, 14.3±0.6, 16.1±4.7, and 19.8±2.4min (mean±SD), respectively. The sensitivity of the species-specific RT-LAMP assays were similar to that of the established RT-PCR and quantitative RT-PCR assays for diagnosis of EVD and are suitable for field or point-of-care diagnosis. The RT-LAMP assays were specific for the detection of the respective species of ebolavirus with no cross reaction with other species of ebolavirus and other viral hemorrhagic fever viruses such as Marburg virus, Lassa fever virus, and Dengue virus. The species-specific RT-LAMP assays developed in this study are rapid, sensitive, and specific and could be useful in case of an EVD outbreak. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Isotope-dilution assay for urinary methylmalonic acid in the diagnosis of vitamin B12 deficiency. A prospective clinical evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matchar, D.B.; Feussner, J.R.; Millington, D.S.

    1987-05-01

    Vitamin B12 deficiency is a frequently considered diagnosis for which there is no single, commonly available and accurate test. A urinary methylmalonic acid assay using gas chromatography-mass spectrometry has been proposed as the preferred test. We reviewed vitamin B12 assays on 1599 consecutive patients and prospectively studied all patients with low serum B12 levels (n = 75) and a random sample of patients with normal levels (n = 68). Of 96 evaluable patients, 7 had clinical deficiency. All 7 deficient patients had urinary methylmalonic acid levels greater than 5 micrograms/mg creatine (sensitivity, 100%; confidence interval, 65% to 100%). Of themore » 89 patients who were not clinically deficient, 88 had urinary methylmalonic acid levels less than or equal to 5 micrograms/mg creatinine (specificity, 99%). The overall test accuracy in this population was 99%. If the high sensitivity and specificity of the gas chromatography-mass spectrometry assay for urinary methylmalonic acid is supported by other clinical studies, the methylmalonic acid assay may become the reference standard for the diagnosis of vitamin B12 deficiency.« less

  4. Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.

    PubMed

    Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen

    2016-12-01

    Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.

  5. Comparative Evaluation of Four Phenotypic Tests for Detection of Carbapenemase-Producing Gram-Negative Bacteria

    PubMed Central

    Noël, Audrey; Berhin, Catherine; Hoebeke, Martin; Bouchahrouf, Warda; Yunus, Sami; Bogaerts, Pierre; Glupczynski, Youri

    2016-01-01

    ABSTRACT Four screening assays aimed for rapid detection of carbapenemase production from Gram-negative bacterial isolates, i.e., the Neo-Rapid Carb kit (Rosco Diagnostica A/S), the Rapidec Carba NP test (bioMérieux SA), the β Carba test (Bio-Rad Laboratories N.V.), and a homemade electrochemical assay (BYG Carba test) were evaluated against a panel comprising 328 clinical isolates (Enterobacteriaceae [n = 198] and nonfermentative Gram-negative bacilli [n = 130]) with previously characterized resistance mechanisms to carbapenems. Among Enterobacteriaceae isolates, the BYG Carba test and the β Carba test showed excellent sensitivities (respectively, 100% and 97.3%) and specificities (respectively, 98.9% and 97.7%). The two other assays yielded poorer performances with sensitivity and specificity of 91.9% and 83.9% for the Rapidec Carba NP test and of 89.2% and 89.7% for the Neo-Rapid Carb kit, respectively. Among Pseudomonas spp., sensitivities and specificities ranged, respectively, from 87.3% to 92.7% and from 88.2% to 94.1%. Finally, all tests performed poorly against Acinetobacter spp., with sensitivities and specificities, respectively, ranging from 27.3% to 75.8% and from 75 to 100%. Among commercially available assays, the β Carba test appeared to be the most convenient for routine use and showed the best overall performances, especially against OXA-48-like producers. The excellent performance of the BYG Carba test against Enterobacteriaceae was confirmed (100% sensitivity and 98.9% specificity). PMID:27927915

  6. Establishing optimal quantitative-polymerase chain reaction assays for routine diagnosis and tracking of minimal residual disease in JAK2-V617F-associated myeloproliferative neoplasms: a joint European LeukemiaNet/MPN&MPNr-EuroNet (COST action BM0902) study.

    PubMed

    Jovanovic, J V; Ivey, A; Vannucchi, A M; Lippert, E; Oppliger Leibundgut, E; Cassinat, B; Pallisgaard, N; Maroc, N; Hermouet, S; Nickless, G; Guglielmelli, P; van der Reijden, B A; Jansen, J H; Alpermann, T; Schnittger, S; Bench, A; Tobal, K; Wilkins, B; Cuthill, K; McLornan, D; Yeoman, K; Akiki, S; Bryon, J; Jeffries, S; Jones, A; Percy, M J; Schwemmers, S; Gruender, A; Kelley, T W; Reading, S; Pancrazzi, A; McMullin, M F; Pahl, H L; Cross, N C P; Harrison, C N; Prchal, J T; Chomienne, C; Kiladjian, J J; Barbui, T; Grimwade, D

    2013-10-01

    Reliable detection of JAK2-V617F is critical for accurate diagnosis of myeloproliferative neoplasms (MPNs); in addition, sensitive mutation-specific assays can be applied to monitor disease response. However, there has been no consistent approach to JAK2-V617F detection, with assays varying markedly in performance, affecting clinical utility. Therefore, we established a network of 12 laboratories from seven countries to systematically evaluate nine different DNA-based quantitative PCR (qPCR) assays, including those in widespread clinical use. Seven quality control rounds involving over 21,500 qPCR reactions were undertaken using centrally distributed cell line dilutions and plasmid controls. The two best-performing assays were tested on normal blood samples (n=100) to evaluate assay specificity, followed by analysis of serial samples from 28 patients transplanted for JAK2-V617F-positive disease. The most sensitive assay, which performed consistently across a range of qPCR platforms, predicted outcome following transplant, with the mutant allele detected a median of 22 weeks (range 6-85 weeks) before relapse. Four of seven patients achieved molecular remission following donor lymphocyte infusion, indicative of a graft vs MPN effect. This study has established a robust, reliable assay for sensitive JAK2-V617F detection, suitable for assessing response in clinical trials, predicting outcome and guiding management of patients undergoing allogeneic transplant.

  7. Evaluation of PCR methods for detection of Brucella strains from culture and tissues.

    PubMed

    Çiftci, Alper; İça, Tuba; Savaşan, Serap; Sareyyüpoğlu, Barış; Akan, Mehmet; Diker, Kadir Serdar

    2017-04-01

    The genus Brucella causes significant economic losses due to infertility, abortion, stillbirth or weak calves, and neonatal mortality in livestock. Brucellosis is still a zoonosis of public health importance worldwide. The study was aimed to optimize and evaluate PCR assays used for the diagnosis of Brucella infections. For this aim, several primers and PCR protocols were performed and compared with Brucella cultures and biological material inoculated with Brucella. In PCR assays, genus- or species-specific oligonucleotide primers derived from 16S rRNA sequences (F4/R2, Ba148/928, IS711, BruP6-P7) and OMPs (JPF/JPR, 31ter/sd) of Brucella were used. All primers except for BruP6-P7 detected the DNA from reference Brucella strains and field isolates. In spiked blood, milk, and semen samples, F4-R2 primer-oriented PCR assays detected minimal numbers of Brucella. In spiked serum and fetal stomach content, Ba148/928 primer-oriented PCR assays detected minimal numbers of Brucella. Field samples collected from sheep and cattle were examined by bacteriological methods and optimized PCR assays. Overall, sensitivity of PCR assays was found superior to conventional bacteriological isolation. Brucella DNA was detected in 35.1, 1.1, 24.8, 5.0, and 8.0% of aborted fetus, blood, milk, semen, and serum samples by PCR assays, respectively. In conclusion, PCR assay in optimized conditions was found to be valuable in sensitive and specific detection of Brucella infections of animals.

  8. Comparison of Two Assays to Determine Anti-Citrullinated Peptide Antibodies in Rheumatoid Arthritis in relation to Other Chronic Inflammatory Rheumatic Diseases: Assaying Anti-Modified Citrullinated Vimentin Antibodies Adds Value to Second-Generation Anti-Citrullinated Cyclic Peptides Testing

    PubMed Central

    Díaz-Toscano, Miriam Lizette; Olivas-Flores, Eva Maria; Zavaleta-Muñiz, Soraya Amali; Gamez-Nava, Jorge Ivan; Cardona-Muñoz, Ernesto German; Ponce-Guarneros, Manuel; Castro-Contreras, Uriel; Nava, Arnulfo; Salazar-Paramo, Mario; Celis, Alfredo; Fajardo-Robledo, Nicte Selene; Corona-Sanchez, Esther Guadalupe; Gonzalez-Lopez, Laura

    2014-01-01

    Determination of anti-citrullinated peptide antibodies (ACPA) plays a relevant role in the diagnosis of rheumatoid arthritis (RA). To date, it is still unclear if the use of several tests for these autoantibodies in the same patient offers additional value as compared to performing only one test. Therefore, we evaluated the performance of using two assays for ACPA: second-generation anti-citrullinated cyclic peptides antibodies (anti-CCP2) and anti-mutated citrullinated vimentin (anti-MCV) antibodies for the diagnosis of RA. We compared three groups: RA (n = 142), chronic inflammatory disease (CIRD, n = 86), and clinically healthy subjects (CHS, n = 56) to evaluate sensitivity, specificity, predictive values, and likelihood ratios (LR) of these two assays for the presence of RA. A lower frequency of positivity for anti-CCP2 was found in RA (66.2%) as compared with anti-MCV (81.0%). When comparing RA versus other CIRD, sensitivity increased when both assays were performed. This strategy of testing both assays had high specificity and LR+. We conclude that adding the assay of anti-MCV antibodies to the determination of anti-CCP2 increases the sensitivity for detecting seropositive RA. Therefore, we propose the use of both assays in the initial screening of RA in longitudinal studies, including early onset of undifferentiated arthritis. PMID:25025037

  9. Dye-binding assays for evaluation of the effects of small molecule inhibitors on amyloid (aβ) self-assembly.

    PubMed

    Jameson, Laramie P; Smith, Nicholas W; Dzyuba, Sergei V

    2012-11-21

    Dye-binding assays, such as those utilizing Congo red and thioflavin T, are among the most widely used tools to probe the aggregation of amyloidogenic biomolecules and for the evaluation of small molecule inhibitors of amyloid aggregation and fibrillization. A number of recent reports have indicated that these dye-binding assays could be prone to false positive effects when assessing inhibitors' potential toward Aβ peptides, species involved in Alzheimer's disease. Specifically, this review focuses on the application of thioflavin T for determining the efficiency of small molecule inhibitors of Aβ aggregation and addresses potential reasons that might be associated with the false positive effects in an effort to increase reliability of dye-binding assays.

  10. Dye-Binding Assays for Evaluation of the Effects of Small Molecule Inhibitors on Amyloid (Aβ) Self-Assembly

    PubMed Central

    2012-01-01

    Dye-binding assays, such as those utilizing Congo red and thioflavin T, are among the most widely used tools to probe the aggregation of amyloidogenic biomolecules and for the evaluation of small molecule inhibitors of amyloid aggregation and fibrillization. A number of recent reports have indicated that these dye-binding assays could be prone to false positive effects when assessing inhibitors’ potential toward Aβ peptides, species involved in Alzheimer’s disease. Specifically, this review focuses on the application of thioflavin T for determining the efficiency of small molecule inhibitors of Aβ aggregation and addresses potential reasons that might be associated with the false positive effects in an effort to increase reliability of dye-binding assays. PMID:23173064

  11. Laboratory tests for identification or exclusion of heparin induced thrombocytopenia: HIT or miss?

    PubMed

    Favaloro, Emmanuel J

    2018-02-01

    Heparin induced thrombocytopenia (HIT) is a potentially fatal condition that arises subsequent to formation of antibodies against complexes containing heparin, usually platelet-factor 4-heparin ("anti-PF4-heparin"). Assessment for HIT involves both clinical evaluation and, if indicated, laboratory testing for confirmation or exclusion, typically using an initial immunological assay ("screening"), and only if positive, a secondary functional assay for confirmation. Many different immunological and functional assays have been developed. The most common contemporary immunological assays comprise enzyme-linked immunosorbent assay [ELISA], chemiluminescence, lateral flow, and particle gel techniques. The most common functional assays measure platelet aggregation or platelet activation events (e.g., serotonin release assay; heparin-induced platelet activation (HIPA); flow cytometry). All assays have some sensitivity and specificity to HIT antibodies, but differ in terms of relative sensitivity and specificity for pathological HIT, as well as false negative and false positive error rate. This brief article overviews the different available laboratory methods, as well as providing a suggested approach to diagnosis or exclusion of HIT. © 2017 Wiley Periodicals, Inc.

  12. Development and evaluation of an avian influenza (AI) neuraminidase subtype 1 (N1) based serological ELISA for poultry using the differentiation of infected and vaccinated animals (DIVA)approach

    USDA-ARS?s Scientific Manuscript database

    An indirect enzyme-linked immunosorbent assay (ELISA) was developed using baculovirus expressed N1 protein from the A/CK/Indonesia/PA/2003 (H5N1) virus. The specificity of the assay was tested with a panel of chicken anti-sera raised against N1 to N9 virus subtypes. The N1-ELISA was specific for t...

  13. Development and evaluation of an avian influenza, neuraminidase subtype 1, indirect enzyme-linked immunosorbent assay for poultry using the differentiation of infected from vaccinated animals control strategy

    USDA-ARS?s Scientific Manuscript database

    An indirect ELISA was developed using baculovirus expressed N1 protein from the A/chicken/Indonesia/7/2003 (H5N1) virus. The specificity of the assay was tested with a panel of chicken antisera raised against N1 to N9 virus subtypes. The N1-ELISA was specific for the detection of N1 antibodies in ...

  14. Detection of Francisella tularensis-Specific Antibodies in Patients with Tularemia by a Novel Competitive Enzyme-Linked Immunosorbent Assay

    PubMed Central

    Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio

    2013-01-01

    A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700

  15. Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for the diagnosis of failure of passive transfer of immunity in foals.

    PubMed

    Davis, Rachel; Giguère, Steeve

    2005-11-15

    To determine and compare sensitivity, specificity, accuracy, and predictive values of measurement of serum total protein concentration by refractometry as well as 5 commercially available kits for the diagnosis of failure of passive transfer (FPT) of immunity in foals. Prospective study. 65 foals with various medical problems and 35 clinically normal foals. IgG concentration in serum was assessed by use of zinc sulfate turbidity (assay C), glutaraldehyde coagulation (assay D), 2 semiquantitative immunoassays (assays F and G), and a quantitative immunoassay (assay H). Serum total protein concentration was assessed by refractometry. Radial immunodiffusion (assays A and B) was used as the reference method. For detection of IgG < 400 mg/dL, sensitivity of assay H (100%) was not significantly different from that of assays C, E, and G (88.9%). Specificity of assays H (96.0%) and G (95.8%) was significantly higher than that of assays C (79.4%) and E (78.1 %). For detection of IgG < 800 mg/dL, sensitivities of assays H (976%), D (92.9%), C (81.0%), and G (81.0%) were significantly higher than that of assay F (52.4%). Specificity of assays F (100%), G (94.7%), and H (82.8%) was significantly higher than that of assays C (56.9%) and D (58.6%). Serum total protein concentration < or = 4.5 g/dL was suggestive of FPT, whereas values > or = 6.0 g/dL indicated adequate IgG concentrations. Most assays were adequate as initial screening tests. However, their use as a definitive test would result in unnecessary treatment of foals with adequate IgG concentrations.

  16. Development and in-use evaluation of a novel Luminex MicroPlex microsphere-based (TRIOL) assay for simultaneous identification of Mycobacterium tuberculosis and detection of first-line and second-line anti-tuberculous drug resistance in China.

    PubMed

    Yin, Feifei; Chan, Jasper Fuk-Woo; Zhu, Qixuan; Fu, Ruijia; Chen, Jonathan Hon-Kwan; Choi, Garnet Kwan-Yue; Tee, Kah-Meng; Li, Lihua; Qian, Shiuyun; Yam, Wing-Cheong; Lu, Gang; Yuen, Kwok-Yung

    2017-04-01

    Rapid and accurate diagnostic assays with simultaneous microbial identification and drug resistance detection are essential for optimising treatment and control of tuberculosis. We developed a novel multiplex (TRIOL, Tuberculosis-Rifampicin-Isoniazid-Ofloxacin-Luminex) assay using the Luminex xMAP system that simultaneously identifies Mycobacterium tuberculosis and detects resistance to first-line and second-line anti-tuberculous drugs, and compared its performance with that by PCR sequencing, using phenotypic drug susceptibility testing as the gold standard. Identification of M. tuberculosis by the TRIOL assay was highly sensitive (100%) and specific (100%). The overall drug-specific specificities were excellent (100%). The overall sensitivity of the TRIOL assay was lower than that of the PCR-sequencing assays (72.4% vs 82.8%) because of a lower sensitivity of detecting rifampicin resistance (71.4% vs 92.9%). The sensitivity of detecting isoniazid and ofloxacin resistance was as good as the PCR-sequencing assays. Importantly, the TRIOL assay did not miss any mutations that were included in the assay. All of the resistant isolates that were missed had uncommon mutations or unknown resistance mechanisms that were not included in the assay. The TRIOL assay has higher throughput, lower cost and is less labour intensive than the PCR-sequencing assays. The TRIOL assay is advantageous in having the capability to detect resistance to multiple drugs and an open-architecture system that allows addition of more specific primers to detect uncommon mutations. Inclusion of additional primers for the identification of non-tuberculous mycobacteria, spoligotyping and improvement of rifampicin resistance detection would enhance the use of the TRIOL assay in future clinical and epidemiological studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Synthesis and Biological Evaluation of Botulinum Neurotoxin A Protease Inhibitors

    PubMed Central

    Li, Bing; Pai, Ramdas; Cardinale, Steven C.; Butler, Michelle M.; Peet, Norton P.; Moir, Donald T.; Bavari, Sina; Bowlin, Terry L.

    2010-01-01

    NSC 240898 was previously identified as a botulinum neurotoxin A light chain (BoNT/A LC) endopeptidase inhibitor by screening the National Cancer Institute Open Repository diversity set. Two types of analogs have been synthesized and shown to inhibit BoNT/A LC in a FRET-based enzyme assay, with confirmation in an HPLC-based assay. These two series of compounds have also been evaluated for inhibition of anthrax lethal factor (LF), an unrelated metalloprotease, to examine enzyme specificity of the BoNT/A LC inhibition. The most potent inhibitor against BoNT/A LC in these two series is compound 12 (IC50 = 2.5 µM, FRET assay), which is 4.4-fold more potent than the lead structure, and 11.2-fold more selective for BoNT/A LC versus the anthrax LF metalloproteinase. Structure-activity relationship studies have revealed structural features important to potency and enzyme specificity. PMID:20155918

  18. Multi-Country Evaluation of the Sensitivity and Specificity of Two Commercially-Available NS1 ELISA Assays for Dengue Diagnosis

    PubMed Central

    Guzman, Maria G.; Jaenisch, Thomas; Gaczkowski, Roger; Ty Hang, Vo Thi; Sekaran, Shamala Devi; Kroeger, Axel; Vazquez, Susana; Ruiz, Didye; Martinez, Eric; Mercado, Juan C.; Balmaseda, Angel; Harris, Eva; Dimano, Efren; Leano, Prisca Susan A.; Yoksan, Sutee; Villegas, Elci; Benduzu, Herminia; Villalobos, Iris; Farrar, Jeremy; Simmons, Cameron P.

    2010-01-01

    Background Early diagnosis of dengue can assist patient triage and management and prevent unnecessary treatments and interventions. Commercially available assays that detect the dengue virus protein NS1 in the plasma/serum of patients offers the possibility of early and rapid diagnosis. Methodology/Principal Findings The sensitivity and specificity of the Pan-E Dengue Early ELISA and the Platelia™ Dengue NS1 Ag assays were compared against a reference diagnosis in 1385 patients in 6 countries in Asia and the Americas. Platelia was more sensitive (66%) than Pan-E (52%) in confirmed dengue cases. Sensitivity varied by geographic region, with both assays generally being more sensitive in patients from SE Asia than the Americas. Both kits were more sensitive for specimens collected within the first few days of illness onset relative to later time points. Pan-E and Platelia were both 100% specific in febrile patients without evidence of acute dengue. In patients with other confirmed diagnoses and healthy blood donors, Platelia was more specific (100%) than Pan-E (90%). For Platelia, when either the NS1 test or the IgM test on the acute sample was positive, the sensitivity versus the reference result was 82% in samples collected in the first four days of fever. NS1 sensitivity was not associated to disease severity (DF or DHF) in the Platelia test, whereas a trend for higher sensitivity in DHF cases was seen in the Pan-E test (however combined with lower overall sensitivity). Conclusions/Significance Collectively, this multi-country study suggests that the best performing NS1 assay (Platelia) had moderate sensitivity (median 64%, range 34–76%) and high specificity (100%) for the diagnosis of dengue. The poor sensitivity of the evaluated assays in some geographical regions suggests further assessments are needed. The combination of NS1 and IgM detection in samples collected in the first few days of fever increased the overall dengue diagnostic sensitivity. PMID:20824173

  19. New design, development, and optimization of an in-house quantitative TaqMan Real-time PCR assay for HIV-1 viral load measurement.

    PubMed

    Noorbazargan, Hassan; Nadji, Seyed Alireza; Samiee, Siamak Mirab; Paryan, Mahdi; Mohammadi-Yeganeh, Samira

    2018-04-01

    Background Viral load measurement is commonly applicable to monitor HIV infection in patients to determine the number of HIV-RNA in serum samples of individuals. The aim of the present study was to set up a highly specific, sensitive, and reproducible home-brewed Real-time PCR assay based on TaqMan chemistry to quantify HIV-1 RNA genome. Methods In this study, three sets of primer pairs and a TaqMan probe were designed for HIV subtypes conserved sequences. An internal control was included in this assay to evaluate the presence of inhibition. Standard curve and threshold cycle values were determined using in vitro transcribed RNA from int region of HIV-1. A serial dilution of RNA standards was generated by in vitro transcription, from 10 to 10 9 copies/ml to find the sensitivity and the limit of detection (LOD) of the assay and to evaluate its performance in a quantitative RT-PCR assay. Results The assay has a low LOD equivalent to 33.13 copies/ml of HIV-1 RNA and a linear range of detection from 10 to 10 9 copies/ml. The coefficient of variation (CV) for Inter and Intra-assay precision of this in-house HIV Real-time RT-PCR ranged from 0.28 to 2.49% and 0.72 to 4.47%, respectively. The analytical and clinical specificity was 100%. Conclusions The results indicate that the developed method has a suitable specificity and sensitivity and is highly reproducible and cost-benefit. Therefore, it will be useful to monitor HIV infection in plasma samples of individuals.

  20. Simultaneous Detection of 13 Key Bacterial Respiratory Pathogens by Combination of Multiplex PCR and Capillary Electrophoresis.

    PubMed

    Jiang, Lu Xi; Ren, Hong Yu; Zhou, Hai Jian; Zhao, Si Hong; Hou, Bo Yan; Yan, Jian Ping; Qin, Tian; Chen, Yu

    2017-08-01

    Lower respiratory tract infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory bacteria. To compensate for the limits of current respiratory bacteria detection methods, we developed a combination of multiplex polymerase chain reaction (PCR) and capillary electrophoresis (MPCE) assay to detect thirteen bacterial pathogens responsible for lower respiratory tract infections, including Streptococcus pneumoniae, Haemophilus influenzae, Moraxella catarrhalis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Escherichia coli, Staphylococcus aureus, Mycoplasma pneumoniae, Legionella spp., Bordetella pertussis, Mycobacterium tuberculosis complex, Corynebacterium diphtheriae, and Streptococcus pyogenes. Three multiplex PCR reactions were built, and the products were analyzed by capillary electrophoresis using the high-throughput DNA analyzer. The specificity of the MPCE assay was examined and the detection limit was evaluated using DNA samples from each bacterial strain and the simulative samples of each strain. This assay was further evaluated using 152 clinical specimens and compared with real-time PCR reactions. For this assay, three nested-multiplex-PCRs were used to detect these clinical specimens. The detection limits of the MPCE assay for the 13 pathogens were very low and ranged from 10-7 to 10-2 ng/μL. Furthermore, analysis of the 152 clinical specimens yielded a specificity ranging from 96.5%-100.0%, and a sensitivity of 100.0% for the 13 pathogens. This study revealed that the MPCE assay is a rapid, reliable, and high-throughput method with high specificity and sensitivity. This assay has great potential in the molecular epidemiological survey of respiratory pathogens. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  1. Development and evaluation of a novel LAMP assay for the diagnosis of Cutaneous and Visceral Leishmaniasis.

    PubMed

    Adams, Emily Rebecca; Schoone, Gerard; Versteeg, Inge; Gomez, Maria Adelaida; Diro, Ermias; Mori, Yasuyoshi; Perlee, Desiree; Downing, Tim; Saravia, Nancy; Assaye, Ashenafi; Hailu, Asrat; Albertini, Audrey; Ndung'u, Joseph Mathu; Schallig, Henk

    2018-04-25

    A novel Pan-Leishmania LAMP assay was developed for diagnosis of Cutaneous and Visceral Leishmaniasis (CL & VL) which can be used in near-patient settings. Primers were designed on the 18S rDNA and the conserved region of minicircle kDNA selected on the basis of high copy number. LAMP assays were evaluated for CL in a prospective cohort trial of 105 patients in South-West Colombia. Lesion swab samples from CL suspects were collected and tested using LAMP and compared to a composite reference of microscopy AND/OR culture to calculate diagnostic accuracy. LAMP assays were tested on 50 VL suspected patients from Ethiopia, including whole blood, peripheral blood mononuclear cells, and buffy coat. Diagnostic accuracy was calculated against a reference standard of microscopy of splenic or bone marrow aspirates. To calculate analytical specificity 100 clinical samples and isolates with fever causing pathogens including malaria, arboviruses and bacterial infections were tested. The LAMP assay had a sensitivity of 95% (95% CI: 87.2% - 98.5 %) and a specificity of 86% (95% CI: 67.3% -95.9 %) for the diagnosis of CL. On VL suspects the sensitivity was 92% (95% CI: 74.9 - 99.1%) and specificity of 100% (95% CI: 85.8-100%) in whole blood. For CL, LAMP is a sensitive tool for diagnosis and requires less equipment, time and expertise than alternative CL diagnostics. For VL, LAMP is sensitive using a minimally invasive sample as compared to the gold standard. The analytical specificity was 100%. Copyright © 2018 Adams et al.

  2. Evaluation of Multiplexed Foot-and-Mouth Disease Nonstructural Protein Antibody Assay Against Standardized Bovine Serum Panel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, J; Parida, S; Clavijo, A

    2007-05-14

    Liquid array technology has previously been used to show proof-of-principle of a multiplexed non structural protein serological assay to differentiate foot-and-mouth infected and vaccinated animals. The current multiplexed assay consists of synthetically produced peptide signatures 3A, 3B and 3D and recombinant protein signature 3ABC in combination with four controls. To determine diagnostic specificity of each signature in the multiplex, the assay was evaluated against a naive population (n = 104) and a vaccinated population (n = 94). Subsequently, the multiplexed assay was assessed using a panel of bovine sera generated by the World Reference Laboratory for foot-and-mouth disease in Pirbright,more » UK. This sera panel has been used to assess the performance of other singleplex ELISA-based non-structural protein antibody assays. The 3ABC signature in the multiplexed assay showed comparative performance to a commercially available non-structural protein 3ABC ELISA (Cedi test{reg_sign}) and additional information pertaining to the relative diagnostic sensitivity of each signature in the multiplex is acquired in one experiment. The encouraging results of the evaluation of the multiplexed assay against a panel of diagnostically relevant samples promotes further assay development and optimization to generate an assay for routine use in foot-and-mouth disease surveillance.« less

  3. A specific endogenous reference for genetically modified common bean (Phaseolus vulgaris L.) DNA quantification by real-time PCR targeting lectin gene.

    PubMed

    Venturelli, Gustavo L; Brod, Fábio C A; Rossi, Gabriela B; Zimmermann, Naíra F; Oliveira, Jaison P; Faria, Josias C; Arisi, Ana C M

    2014-11-01

    The Embrapa 5.1 genetically modified (GM) common bean was approved for commercialization in Brazil. Methods for the quantification of this new genetically modified organism (GMO) are necessary. The development of a suitable endogenous reference is essential for GMO quantification by real-time PCR. Based on this, a new taxon-specific endogenous reference quantification assay was developed for Phaseolus vulgaris L. Three genes encoding common bean proteins (phaseolin, arcelin, and lectin) were selected as candidates for endogenous reference. Primers targeting these candidate genes were designed and the detection was evaluated using the SYBR Green chemistry. The assay targeting lectin gene showed higher specificity than the remaining assays, and a hydrolysis probe was then designed. This assay showed high specificity for 50 common bean samples from two gene pools, Andean and Mesoamerican. For GM common bean varieties, the results were similar to those obtained for non-GM isogenic varieties with PCR efficiency values ranging from 92 to 101 %. Moreover, this assay presented a limit of detection of ten haploid genome copies. The primers and probe developed in this work are suitable to detect and quantify either GM or non-GM common bean.

  4. Development of recombinase polymerase amplification assays for the rapid detection of peste des petits ruminants virus.

    PubMed

    Zhang, Yongning; Wang, Jianchang; Zhang, Zhou; Mei, Lin; Wang, Jinfeng; Wu, Shaoqiang; Lin, Xiangmei

    2018-04-01

    Peste des petits ruminants (PPR) is a severe infectious disease of small ruminants caused by PPR virus (PPRV). Rapid and sensitive detection of PPRV is critical for controlling PPR. This report describes the development and evaluation of a conventional reverse transcription recombinase polymerase amplification (RT-RPA) assay and a real-time RT-RPA assay, targeting the PPRV N gene. Sensitivity analysis revealed that the conventional RT-RPA assay could detect 852 copies of standard PPRV RNA per reaction at 95% probability within 20 min at 41 °C, and the real-time RT-RPA assay could detect 103 copies of RNA molecules per reaction at 95% probability. Specificity analysis showed that both assays have no cross-reactivity with nucleic acid templates prepared from other selected viruses or common pathogens. Clinical evaluation using 162 ovine and hircine serum and nasal swab samples showed that the performance of both the real-time RT-RPA assay and the conventional RT-RPA assay were comparable to that of real-time RT-PCR. The overall agreements between real-time RT-PCR and real-time RT-RPA, and conventional RT-RPA were 99.4% (161/162) and 98.8% (160/162), respectively. The R 2 value of real-time RT-RPA and real-time RT-PCR was 0.900 by linear regression analysis. Our results suggest that both RT-RPA assays have a potential application in the rapid, sensitive and specific detection of PPRV. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Multiplex polymerase chain reaction assay developed to diagnose adult bacterial meningitis in Taiwan.

    PubMed

    Lee, Chi-Tsung; Hsiao, Kuang-Ming; Chen, Jin-Cherng; Su, Cheng-Chuan

    2015-11-01

    Acute bacterial meningitis causes high morbidity and mortality; the associated clinical symptoms often are insensitive or non-specific; and the pathogenic bacteria are geographically diverse. Clinical diagnosis requires a rapid and accurate methodology. This study aimed to develop a new multiplex polymerase chain reaction (mPCR) assay to detect simultaneously six major bacteria that cause adult bacterial meningitis in Taiwan: Klebsiella pneumoniae, Pseudomonas aeruginosa, Streptococcus pneumoniae, Staphylococcus aureus, Escherichia coli, and Acinetobacter baumannii. Species-specific primers for the six bacteria were developed using reference strains. The specificities of the mPCRs for these bacteria were validated, and the sensitivities were evaluated via serial dilutions. The mPCR assay specifically detected all of the six pathogens, particularly with sensitivities of 12 colony forming units (CFU)/mL, 90 CFU/mL, and 390 CFU/mL for E. coli, S. pneumoniae, and K. pneumoniae, respectively. This mPCR assay is a rapid and specific tool to detect the six major bacterial pathogens that cause acute adult meningitis in Taiwan, particularly sensitive for detecting E. coli, S. pneumoniae, and K. pneumoniae. The assay may facilitate early diagnosis and guidance for antimicrobial therapy for adult patients with this deadly disease in Taiwan. © 2015 APMIS. Published by John Wiley & Sons Ltd.

  6. Comparison of the genexpert enterovirus assay (GXEA) with real-time one step RT-PCR for the detection of enteroviral RNA in the cerebrospinal fluid of patients with meningitis.

    PubMed

    Hong, JiYoung; Kim, Ahyoun; Hwang, Seoyeon; Cheon, Doo-Sung; Kim, Jong-Hyen; Lee, June-Woo; Park, Jae-Hak; Kang, Byunghak

    2015-02-13

    Enteroviruses (EVs) are the leading cause of aseptic meningitis worldwide. Detection of enteroviral RNA in clinical specimens has been demonstrated to improve the management of patient care, especially that of neonates and young children. To establish a sensitive and reliable assay for routine laboratory diagnosis, we compared the sensitivity and specificity of the GeneXpert Enterovirus Assay (GXEA) with that of the reverse transcription polymerase chain reaction (RT-PCR) based assay referred to as real-time one step RT-PCR (RTo-PCR). The sensitivity/specificity produced by GXEA and RTo-PCR were 100%/100% and 65%/100%, respectively. Both methods evaluated in this article can be used for detection of enterovirus in clinical specimens and these nucleic acid amplification methods are useful assays for the diagnosis of enteroviral infection.

  7. Diagnosing systemic lupus erythematosus: new-generation immunoassays for measurement of anti-dsDNA antibodies are an effective alternative to the Farr technique and the Crithidia luciliae immunofluorescence test.

    PubMed

    Antico, A; Platzgummer, S; Bassetti, D; Bizzaro, N; Tozzoli, R; Villalta, D

    2010-07-01

    The aim of this study was to evaluate the diagnostic performance of four new enzyme immunoassays (EIAs) for anti-double-stranded-DNA (anti-dsDNA) antibodies, in comparison with the Farr assay and the Crithidia luciliae immunofluorescence test (CLIFT). To this purpose, sera from four patient groups were collected: 52 sera from patients with systemic lupus erythematosus (SLE); 28 from patients with other connective tissue diseases (CTD); 36 from patients with hepatitis C virus (HCV) infection; and 24 from those with acute viral infection. All sera were tested for anti-dsDNA antibodies by four EIA methods using a different antigenic DNA source [synthetic oligonucleotide (Method A), circular plasmid (Method B), recombinant (Method C), and purified extracted (Method D)], and by CLIFT and Farr assays. The diagnostic sensitivity of the assays was as follows: 84.6% (Method A), 73% (B), 82.7% (C), 84.6% (D), 55.8% (CLIFT), and 78.8% (Farr). Specificity was 82.9% (A), 97.7% (B), 96.5% (C), 94.3% (D), 96.5% (CLIFT), and 90.9% (Farr). From these data, we can conclude that the new-generation EIA methods evaluated in this study have higher sensitivity than the CLIFT and Farr assays and, with the exception of Method A, have specificity similar to the CLIFT and slightly higher than the Farr assay. These findings suggest that EIA tests may replace CLIFT as a screening test and the Farr assay as a specific test, for anti-dsDNA antibody detection.

  8. Recombinant protein-based assays for detection of antibodies to severe acute respiratory syndrome coronavirus spike and nucleocapsid proteins.

    PubMed

    Haynes, Lia M; Miao, Congrong; Harcourt, Jennifer L; Montgomery, Joel M; Le, Mai Quynh; Dryga, Sergey A; Kamrud, Kurt I; Rivers, Bryan; Babcock, Gregory J; Oliver, Jennifer Betts; Comer, James A; Reynolds, Mary; Uyeki, Timothy M; Bausch, Daniel; Ksiazek, Thomas; Thomas, William; Alterson, Harold; Smith, Jonathan; Ambrosino, Donna M; Anderson, Larry J

    2007-03-01

    Recombinant severe acute respiratory syndrome (SARS) nucleocapsid and spike protein-based immunoglobulin G immunoassays were developed and evaluated. Our assays demonstrated high sensitivity and specificity to the SARS coronavirus in sera collected from patients as late as 2 years postonset of symptoms. These assays will be useful not only for routine SARS coronavirus diagnostics but also for epidemiological and antibody kinetic studies.

  9. Recombinant Protein-Based Assays for Detection of Antibodies to Severe Acute Respiratory Syndrome Coronavirus Spike and Nucleocapsid Proteins▿

    PubMed Central

    Haynes, Lia M.; Miao, Congrong; Harcourt, Jennifer L.; Montgomery, Joel M.; Le, Mai Quynh; Dryga, Sergey A.; Kamrud, Kurt I.; Rivers, Bryan; Babcock, Gregory J.; Oliver, Jennifer Betts; Comer, James A.; Reynolds, Mary; Uyeki, Timothy M.; Bausch, Daniel; Ksiazek, Thomas; Thomas, William; Alterson, Harold; Smith, Jonathan; Ambrosino, Donna M.; Anderson, Larry J.

    2007-01-01

    Recombinant severe acute respiratory syndrome (SARS) nucleocapsid and spike protein-based immunoglobulin G immunoassays were developed and evaluated. Our assays demonstrated high sensitivity and specificity to the SARS coronavirus in sera collected from patients as late as 2 years postonset of symptoms. These assays will be useful not only for routine SARS coronavirus diagnostics but also for epidemiological and antibody kinetic studies. PMID:17229882

  10. Performance characteristics of the new Abbott Real Time MTB assay for detection of Mycobacterium tuberculosis complex in respiratory specimens.

    PubMed

    Vinuesa, Víctor; Navarro, David; Poujois, Sandrine; Zaragoza, Susana; Borrás, Rafael

    2016-03-01

    The performance of the Abbott Real Time MTB assay for detection of Mycobacterium tuberculosis complex in respiratory specimens was evaluated using a standard culture as the reference. The overall concordance between both methods was 0.95. The assay displayed an excellent sensitivity (100% for smear-positive/92.3% for smear-negative specimens) and specificity (100%). Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0.

    PubMed

    Worlock, A; Blair, D; Hunsicker, M; Le-Nguyen, T; Motta, C; Nguyen, C; Papachristou, E; Pham, J; Williams, A; Vi, M; Vinluan, B; Hatzakis, A

    2017-04-04

    The Aptima HCV Quant Dx assay (Aptima assay) is a fully automated quantitative assay on the Panther® system. This assay is intended for confirmation of diagnosis and monitoring of HCV RNA in plasma and serum specimens. The purpose of the testing described in this paper was to evaluate the performance of the Aptima assay. The analytical sensitivity, analytical specificity, precision, and linearity of the Aptima assay were assessed. The performance of the Aptima assay was compared to two commercially available HCV assays; the Abbott RealTime HCV assay (Abbott assay, Abbott Labs Illinois, USA) and the Roche COBAS Ampliprep/COBAS Taqman HCV Quantitative Test v2.0 (Roche Assay, Roche Molecular Systems, Pleasanton CA, USA). The 95% Lower Limit of Detection (LoD) of the assay was determined from dilutions of the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) and HCV positive clinical specimens in HCV negative human plasma and serum. Probit analysis was performed to generate the 95% predicted detection limits. The Lower Limit of Quantitation (LLoQ) was established for each genotype by diluting clinical specimens and the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) in HCV negative human plasma and serum. Specificity was determined using 200 fresh and 536 frozen HCV RNA negative clinical specimens including 370 plasma specimens and 366 serum specimens. Linearity for genotypes 1 to 6 was established by diluting armored RNA or HCV positive clinical specimens in HCV negative serum or plasma from 8.08 log IU/mL to below 1 log IU/mL. Precision was tested using a 10 member panel made by diluting HCV positive clinical specimens or spiking armored RNA into HCV negative plasma and serum. A method comparison was conducted against the Abbott assay using 1058 clinical specimens and against the Roche assay using 608 clinical specimens from HCV infected patients. In addition, agreement between the Roche assay and the Aptima assay using specimens with low HCV concentrations (

  12. Multicenter Clinical Evaluation of the Alere i Respiratory Syncytial Virus Isothermal Nucleic Acid Amplification Assay.

    PubMed

    Hassan, Ferdaus; Hays, Lindsay M; Bonner, Aleta; Bradford, Bradley J; Franklin, Ruffin; Hendry, Phyllis; Kaminetsky, Jed; Vaughn, Michael; Cieslak, Kristin; Moffatt, Mary E; Selvarangan, Rangaraj

    2018-03-01

    The Alere i respiratory syncytial virus (RSV) assay is an isothermal nucleic acid amplification test capable of detecting RSV directly from respiratory specimens, with results being available in ≤13 min after test initiation. The objective of this study was to evaluate the performance characteristics of the Alere i RSV assay in a point-of-care setting by using direct nasopharyngeal (NP) swab specimens (direct NP) and nasopharyngeal swab specimens eluted and transported in viral transport medium (VTM NP). The study was a prospective, multicenter, clinical trial conducted at 9 sites across the United States to evaluate the clinical performance of the Alere i RSV assay with respiratory specimens obtained from both children (age, <18 years) and older adults (age, >60 years). The performance of the Alere i RSV assay was compared with that of the reference method, the Prodesse ProFlu+ real-time reverse transcriptase PCR (RT-PCR) assay. All specimens with discrepant test results were tested further by a second FDA-cleared PCR assay (the Verigene respiratory virus plus nucleic acid test; Luminex Inc., TX). A total of 554 subjects with signs and symptoms of respiratory infections were enrolled, and respiratory samples were collected in this study. In comparison with the ProFlu+ real-time RT-PCR, the overall sensitivity and specificity of Alere i RSV assay for the detection of RSV were 98.6% (95% confidence interval [CI], 94.4 to 99.7%) and 98.0% (95% CI, 95.8 to 99.1%), respectively, for direct NP and 98.6% (95% CI, 94.4 to 99.7%) and 97.8% (95% CI, 95.5 to 98.9%), respectively, for VTM NP. The Alere i RSV is a highly sensitive and specific molecular assay ideal for rapid RSV detection in patients in the point-of-care setting due to its minimal hands-on time and rapid result availability. Copyright © 2018 American Society for Microbiology.

  13. Design and Development of a Quantitative TaqMan Real-Time PCR Assay for Evaluation of HIV-1 (group M) Viral Load in Plasma Using Armored RNA Standard.

    PubMed

    Gholami, Mohammad; Baesi, Kazem; Rouzbahani, Negin H; Mohraz, Minoo

    2018-06-01

    Human immunodeficiency virus-1 (HIV-1) is a viral infectious agent that gradually extinguishes the immune system, resulting in the acquired immune deficiency syndrome (AIDS). The aim of this study was to develop a TaqMan based detection assay to evaluate HIV-1 plasma viral load and to construct a stable internal positive control (IPC) and external positive control (EPC) RNA based on Armored RNA (AR) technology. The MS2 maturase, coat protein gene and HIV-1 pol gene were cloned in pET-32a plasmid. The recently fabricated recombinant plasmid was transformed into Escherichia coli strain BL2 (DE3) and protein expression and Armored RNA was fabricated in presence of isopropyl-L-thio-D-galactopyranoside (IPTG). The Armored RNA was precipitated and purified by polyethylene glycol (PEG) and sephacryl S-200 chromatography. The stability of Armored RNA was evaluated by treatment with DNase I and RNase A and confirmed by transmission electron microscopy (TEM) and gel agarose electrophoresis. The specificity, sensitivity, inter- and intra-day precision, and the dynamic range of the assay were experimentally determined. The AR was stable in presence of ribonuclease, and the assay had a dynamic detection range from 101 to 105 copies of AR. The coefficient of variation (CV) was 4.8% for intra-assay and 5.8% for inter-assay precision. Clinical specificity and sensitivity of the assay were assessed at 100% and 96.66%, respectively. The linear regression analysis confirmed a high correlation between the in-house and the commercial assay, Real Star HIV-1-qRTPCR, respectively (R2 = 0.888). The AR standard is non-infectious and highly resistant in the presence of ribonuclease. The TaqMan assay developed is able to quantify HIV viral load based on a novel conserved region of HIV-1 pol gene which has minimal sequence inconsistency.

  14. Evaluation of the ICT Malaria P.f/P.v and the OptiMal Rapid Diagnostic Tests for Malaria in Febrile Returned Travellers

    PubMed Central

    Playford, E. Geoffrey; Walker, John

    2002-01-01

    Rapid diagnostic tests (RDTs) are less reliant on expert microscopy and have the potential to reduce errors in malaria diagnosis but have not been extensively evaluated in nonimmune persons or in countries where infection is not endemic. We evaluated the ICT P.f/P.v (ICT-Amrad, Sydney, Australia) and OptiMal (Flow Inc., Portland, Oreg.) assays prospectively for the diagnosis of malaria in 158 specimens from 144 febrile returned travellers in Australia by using expert microscopy and PCR as reference standards. Malaria was diagnosed in 93 specimens from 87 patients by expert microscopy, with 3 additional specimens from recently treated patients testing positive for Plasmodium falciparum by PCR. For the diagnosis of asexual-stage P. falciparum malaria, the sensitivity and specificity of the ICT P.f/P.v assay were 97 and 90%, respectively, and those of the OptiMal assay were 85 and 96%, respectively. The ICT P.f/P.v assay missed one infection with a density of 45 parasites/μl, whereas the OptiMal assay missed infections up to 2,500/μl; below 1,000/μl, its sensitivity was only 43%. For the diagnosis of P. vivax malaria, the sensitivity and specificity of the ICT P.f/P.v assay were 44 and 100%, respectively, and those of the OptiMal assay were 80 and 97%, respectively. Both assays missed infections with parasite densities over 5,000/μl: up to 10,000/μl with the former and 5,300/μl with the latter. Despite the high sensitivity of the ICT P.f/P.v assay for P. falciparum malaria, caution is warranted before RDTs are widely adopted for the diagnosis of malaria in nonimmune patients or in countries where malaria is not endemic. PMID:12409392

  15. Field evaluation of a recombinase polymerase amplification assay for the diagnosis of Schistosoma japonicum infection in Hunan province of China.

    PubMed

    Xing, Weiwei; Yu, Xinling; Feng, Jingtao; Sun, Kui; Fu, Wenliang; Wang, Yuanyuan; Zou, Minji; Xia, Wenrong; Luo, Zhihong; He, Hongbin; Li, Yuesheng; Xu, Donggang

    2017-02-21

    Current diagnostic methods for Schistosoma japonicum infection are insensitive for low-density infections. Therefore, a new diagnostic assay based on recombinase polymerase amplification (RPA) technology was established and assessed for field applification. The S.japonicum RPA assay was developed to target highly repetitive retrotransposon SjR2 gene of S japonicum, and its sensitivity and specificity were assessed by serial dilution of S. japonicum genomic DNA and other related worm genomic DNA respectively. The RPA diagnostic validity was first evaluated in 60 fecal samples from healthy people and patients, and then compared with other diagnostic tests in 200 high-risk individuals living in endemic areas. The real time RPA assay could detect 0.9 fg S. japonicum DNA within 15 min and distinguish S. japonicum from other worms. The validity analysis of RPA for the detection of S. japonicum in stool samples from 30 S. japonicum-infected patients and 30 healthy persons indicated 100% sensitivity and specificity. When testing 200 fecal or serum samples from a high-risk population, the percentage sensitivity of RPA was 100%, whereas that of indirect hemagglutination assay (IHA) and enzyme-linked immunosorbent assay (ELISA) were 80.3% and 85.2% respectively. In addition, the RPA presented better consistency with the stool-based tests than IHA and ELISA. Overall, the RPA was superior to other detection methods with respect to detection time, sensitivity, and convenience. This is the first time we applied the RPA technology to the field evaluation of S. japonicum infection. And the results suggest that RPA-based assays can be used as a promising point-of-care test for the diagnosis of schistosomiasis.

  16. Evaluation of a new automated Abbott RealTime MTB RIF/INH assay for qualitative detection of rifampicin/isoniazid resistance in pulmonary and extra-pulmonary clinical samples of Mycobacterium tuberculosis.

    PubMed

    Ruiz, Pilar; Causse, Manuel; Vaquero, Manuel; Gutierrez, Juan Bautista; Casal, Manuel

    2017-01-01

    A new automated real-time PCR assay for the detection of rifampicin (RIF) and isoniazid (INH) resistance in Mycobacterium tuberculosis (MTB) was evaluated. A total of 163 clinical samples (128 pulmonary and 35 extra-pulmonary) were processed using four PCR assay kits: Abbott RealTime MTB RIF/INH, Genotype MTBDRplus, Xpert/MTB RIF, and Anyplex MTB/MDR. The results of phenotypic drug-susceptibility testing using BACTECMGIT 960 were used as reference. The sensitivity and specificity of the new Abbott RealTime MTB RIF/INH assay in comparison with phenotypic testing was 96.3% (95%CI 87.32%-100%) for RIF and 100% (95%CI 99.3%-100%) for INH; the sensitivity was 78.8% (95%CI 66.8%-90.9%) and the specificity was 100% (95%CI 98.9%-100%). The Abbott RealTime MTB RIF/INH test could be a valid method for detecting the most common mutations in strains resistant to RIF and INH.

  17. Use of high-throughput in vitro toxicity screening data in cancer hazard evaluations by IARC Monograph Working Groups

    PubMed Central

    Chiu, Weihsueh A.; Guyton, Kathryn Z.; Martin, Matthew T.; Reif, David M.; Rusyn, Ivan

    2017-01-01

    Evidence regarding carcinogenic mechanisms serves a critical role in International Agency for Research on Cancer (IARC) Monograph evaluations. Three recent IARC Working Groups pioneered inclusion of the US Environmental Protection Agency (EPA) ToxCast program high-throughput screening (HTS) data to supplement other mechanistic evidence. In Monograph V110, HTS profiles were compared between perfluorooctanoic acid (PFOA) and prototypical activators across multiple nuclear receptors. For Monograph V112 -113, HTS assays were mapped to 10 key characteristics of carcinogens identified by an IARC expert group, and systematically considered as an additional mechanistic data stream. Both individual assay results and ToxPi-based rankings informed mechanistic evaluations. Activation of multiple nuclear receptors in HTS assays showed that PFOA targets peroxisome proliferator activated and other receptors. ToxCast assays substantially covered 5 of 10 key characteristics, corroborating literature evidence of “induces oxidative stress” and “alters cell proliferation, cell death or nutrient supply” and filling gaps for “modulates receptor-mediated effects.” Thus, ToxCast HTS data were useful both in evaluating specific mechanistic hypotheses and in the overall evaluation of mechanistic evidence. However, additional HTS assays are needed to provide more comprehensive coverage of the 10 key characteristics of carcinogens that form the basis of current IARC mechanistic evaluations. PMID:28738424

  18. Use of high-throughput in vitro toxicity screening data in cancer hazard evaluations by IARC Monograph Working Groups.

    PubMed

    Chiu, Weihsueh A; Guyton, Kathryn Z; Martin, Matthew T; Reif, David M; Rusyn, Ivan

    2018-01-01

    Evidence regarding carcinogenic mechanisms serves a critical role in International Agency for Research on Cancer (IARC) Monograph evaluations. Three recent IARC Working Groups pioneered inclusion of the US Environmental Protection Agency (EPA) ToxCast program high-throughput screening (HTS) data to supplement other mechanistic evidence. In Monograph V110, HTS profiles were compared between perfluorooctanoic acid (PFOA) and prototypical activators across multiple nuclear receptors. For Monograph V112-113, HTS assays were mapped to 10 key characteristics of carcinogens identified by an IARC expert group, and systematically considered as an additional mechanistic data stream. Both individual assay results and ToxPi-based rankings informed mechanistic evaluations. Activation of multiple nuclear receptors in HTS assays showed that PFOA targets not only peroxisome proliferator activated receptors, but also other receptors. ToxCast assays substantially covered 5 of 10 key characteristics, corroborating literature evidence of "induces oxidative stress" and "alters cell proliferation, cell death or nutrient supply" and filling gaps for "modulates receptor-mediated effects." Thus, ToxCast HTS data were useful both in evaluating specific mechanistic hypotheses and in contributing to the overall evaluation of mechanistic evidence. However, additional HTS assays are needed to provide more comprehensive coverage of the 10 key characteristics of carcinogens that form the basis of current IARC mechanistic evaluations.

  19. Development and deployment of a rapid recombinase polymerase amplification Ebola virus detection assay in Guinea in 2015.

    PubMed

    Faye, Oumar; Faye, Ousmane; Soropogui, Barré; Patel, Pranav; El Wahed, Ahmed Abd; Loucoubar, Cheikh; Fall, Gamou; Kiory, Davy; Magassouba, N'Faly; Keita, Sakoba; Kondé, Mandy Kader; Diallo, Alpha Amadou; Koivogui, Lamine; Karlberg, Helen; Mirazimi, Ali; Nentwich, Oliver; Piepenburg, Olaf; Niedrig, Matthias; Weidmann, Manfred; Sall, Amadou Alpha

    2015-01-01

    In the absence of a vaccine or specific treatments for Ebola virus disease (EVD), early identification of cases is crucial for the control of EVD epidemics. We evaluated a new extraction kit (SpeedXtract (SE), Qiagen) on sera and swabs in combination with an improved diagnostic reverse transcription recombinase polymerase amplification assay for the detection of Ebola virus (EBOV-RT-RPA). The performance of combined extraction and detection was best for swabs. Sensitivity and specificity of the combined SE and EBOV-RT-RPA were tested in a mobile laboratory consisting of a mobile glovebox and a Diagnostics-in-a-Suitcase powered by a battery and solar panel, deployed to Matoto Conakry, Guinea as part of the reinforced surveillance strategy in April 2015 to reach the goal of zero cases. The EBOV-RT-RPA was evaluated in comparison to two real-time PCR assays. Of 928 post-mortem swabs, 120 tested positive, and the combined SE and EBOV-RT-RPA yielded a sensitivity and specificity of 100% in reference to one real-time RT-PCR assay. Another widely used real-time RT-PCR was much less sensitive than expected. Results were provided very fast within 30 to 60 min, and the field deployment of the mobile laboratory helped improve burial management and community engagement.

  20. Contribution of murine innate serum inhibitors toward interference within influenza virus immune assays.

    PubMed

    Cwach, Kevin T; Sandbulte, Heather R; Klonoski, Joshua M; Huber, Victor C

    2012-03-01

    Prior to detection of an antibody response toward influenza viruses using the hemagglutination inhibition assay (HAI), sera are routinely treated to inactivate innate inhibitors using both heat inactivation (56°C) and recombinant neuraminidase [receptor-destroying enzyme (RDE)]. We revisited the contributions of innate serum inhibitors toward interference with influenza viruses in immune assays, using murine sera, with emphasis on the interactions with influenza A viruses of the H3N2 subtype. We used individual serum treatments: 56°C alone, RDE alone, or RDE + 56°C, to treat sera prior to evaluation within HAI, microneutralization, and macrophage uptake assays. Our data demonstrate that inhibitors present within untreated murine sera interfere with the HAI assay in a manner that is different from that seen for the microneutralization assay. Specifically, the γ class inhibitor α(2) -Macroglobulin (A2-M) can inhibit H3N2 viruses within the HAI assay, but not in the microneutralization assay. Based on these findings, we used a macrophage uptake assay to demonstrate that these inhibitors can increase uptake by macrophages when the influenza viruses express an HA from a 1968 H3N2 virus isolate, but not a 1997 H3N2 isolate. The practice of treating sera to inactivate innate inhibitors of influenza viruses prior to evaluation within immune assays has allowed us to effectively detect influenza virus-specific antibodies for decades. However, this practice has yielded an under-appreciation for the contribution of innate serum inhibitors toward host immune responses against these viruses, including contributions toward neutralization and macrophage uptake. © 2011 Blackwell Publishing Ltd.

  1. Clinical evaluation of a loop-mediated isothermal amplification (LAMP) assay for rapid detection of Neisseria meningitidis in cerebrospinal fluid.

    PubMed

    Lee, DoKyung; Kim, Eun Jin; Kilgore, Paul E; Kim, Soon Ae; Takahashi, Hideyuki; Ohnishi, Makoto; Anh, Dang Duc; Dong, Bai Qing; Kim, Jung Soo; Tomono, Jun; Miyamoto, Shigehiko; Notomi, Tsugunori; Kim, Dong Wook; Seki, Mitsuko

    2015-01-01

    Neisseria meningitidis (Nm) is a leading causative agent of bacterial meningitis in humans. Traditionally, meningococcal meningitis has been diagnosed by bacterial culture. However, isolation of bacteria from patients' cerebrospinal fluid (CSF) is time consuming and sometimes yields negative results. Recently, polymerase chain reaction (PCR)-based diagnostic methods of detecting Nm have been considered the gold standard because of their superior sensitivity and specificity compared with culture. In this study, we developed a loop-mediated isothermal amplification (LAMP) method and evaluated its ability to detect Nm in cerebrospinal fluid (CSF). We developed a meningococcal LAMP assay (Nm LAMP) that targets the ctrA gene. The primer specificity was validated using 16 strains of N. meningitidis (serogroup A, B, C, D, 29-E, W-135, X, Y, and Z) and 19 non-N. meningitidis species. Within 60 min, the Nm LAMP detected down to ten copies per reaction with sensitivity 1000-fold more than that of conventional PCR. The LAMP assays were evaluated using a set of 1574 randomly selected CSF specimens from children with suspected meningitis collected between 1998 and 2002 in Vietnam, China, and Korea. The LAMP method was shown to be more sensitive than PCR methods for CSF samples (31 CSF samples were positive by LAMP vs. 25 by PCR). The detection rate of the LAMP method was substantially higher than that of the PCR method. In a comparative analysis of the PCR and LAMP assays, the clinical sensitivity, specificity, positive predictive value, and negative predictive value of the LAMP assay were 100%, 99.6%, 80.6%, and 100%, respectively. Compared to PCR, LAMP detected Nm with higher analytical and clinical sensitivity. This sensitive and specific LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings.

  2. Evaluation of Five Antibody Detection Tests for Diagnosis of Bovine Paratuberculosis

    PubMed Central

    Collins, Michael T.; Wells, Scott J.; Petrini, Kristine R.; Collins, James E.; Schultz, Ronald D.; Whitlock, Robert H.

    2005-01-01

    Five diagnostic tests based on enzyme-linked immunosorbent assay (ELISA) technology for bovine paratuberculosis were evaluated by using individual serum or milk samples from 359 dairy cattle in seven paratuberculosis-free herds and 2,094 dairy cattle in seven Mycobacterium paratuberculosis-infected dairy herds. Three independent laboratories using three different culture procedures completed fecal cultures for M. paratuberculosis on these cattle and found 417 cows to be shedding M. paratuberculosis in their feces. An animal that was fecal culture positive for M. paratuberculosis by any of the three laboratories was considered a confirmed case of infection. The specificity of three ELISAs (two on serum and one on milk) was ≥99.8%. The specificity of the remaining two ELISAs, both done on serum, was 94.9 and 84.7%. Four of the five ELISAs evaluated produced similar sensitivity in detecting fecal culture-positive cattle (27.8 to 28.9%). Serum ELISA “D” had the lowest specificity (84.7%) and the highest sensitivity (44.5%), but if the cutoff value defining a positive test was changed from 125 to 250% (of the positive control) the sensitivity and specificity, 31.8 and 97.5%, respectively, were comparable to those of the other four assays. If the case definition for M. paratuberculosis infection was based on the culture results of a single laboratory instead of the combined results of three laboratories, ELISA sensitivity estimates were 45.7 to 50.0%. With the exception of ELISA D, assay agreement was high (kappa 0.66 to 0.85) for categorical assay interpretations (positive or negative), but linear regression of quantitative results showed low correlation coefficients (r2 = 0.40 to 0.68) due to the fact that ELISA results for some cows were high in one assay but low in another assay. Likelihood ratio analysis showed a direct relationship between the magnitude of ELISA result and the odds of a cow shedding M. paratuberculosis in its feces. If used judiciously and interpreted quantitatively, these ELISAs are useful tools in support of paratuberculosis control programs in dairy herds. PMID:15939741

  3. Development and Evaluation of a Novel Loop-Mediated Isothermal Amplification Method for Rapid Detection of Severe Acute Respiratory Syndrome Coronavirus

    PubMed Central

    Thai, Hong Thi Cam; Le, Mai Quynh; Vuong, Cuong Duc; Parida, Manmohan; Minekawa, Harumi; Notomi, Tsugunori; Hasebe, Futoshi; Morita, Kouichi

    2004-01-01

    The development and evaluation of a one-step single-tube accelerated real-time quantitative reverse transcription (RT) loop-mediated isothermal amplification (LAMP) assay is reported for rapid detection of the severe acute respiratory syndrome coronavirus (SARS-CoV) replicase gene. A total of 49 samples (15 throat washes, 13 throat swabs, and 21 combined throat and nasal swabs) collected from patients admitted to the Hanoi-French and Ninhbinh hospitals in Vietnam during the SARS epidemic were evaluated and compared to conventional RT-PCR. The RT-LAMP assay demonstrated 100-fold-greater sensitivity, with a detection limit of 0.01 PFU. The sensitivity and specificity of RT-LAMP assay for detecting viral RNA in clinical specimens with regard to RT-PCR were 100 and 87%, respectively. The specificity of the RT-LAMP assay was further validated by restriction analysis as well as nucleotide sequencing of the amplified product. The concentration of virus in most of the clinical samples was 0.1 PFU (0.1 to 102 PFU), as determined from the standard curve of SARS RT-LAMP and based on the time of positivity. The assay procedure is quite simple, wherein the amplification is carried out in a single tube under isothermal conditions at 63°C, and the result can be obtained in less than 1 h (as early as 11 min). Thus, the RT-LAMP assay reported here has the advantages of rapid amplification, simple operation, and easy detection and will be useful for rapid and reliable clinical diagnosis of SARS-CoV in developing countries. PMID:15131154

  4. Laboratory Evaluation of the Liat HIV Quant (IQuum) Whole-Blood and Plasma HIV-1 Viral Load Assays for Point-of-Care Testing in South Africa

    PubMed Central

    Gous, Natasha; Carmona, Sergio; Stevens, Wendy

    2015-01-01

    Point-of-care (POC) HIV viral load (VL) testing offers the potential to reduce turnaround times for antiretroviral therapy monitoring, offer near-patient acute HIV diagnosis in adults, extend existing centralized VL services, screen women in labor, and prompt pediatrics to early treatment. The Liat HIV Quant plasma and whole-blood assays, prerelease version, were evaluated in South Africa. The precision, accuracy, linearity, and agreement of the Liat HIV Quant whole-blood and plasma assays were compared to those of reference technologies (Roche CAP CTMv2.0 and Abbott RealTime HIV-1) on an HIV verification plasma panel (n = 42) and HIV clinical specimens (n = 163). HIV Quant plasma assay showed good performance, with a 2.7% similarity coefficient of variation (CV) compared to the Abbott assay and a 1.8% similarity CV compared to the Roche test on the verification panel, and 100% specificity. HIV Quant plasma had substantial agreement (pc [concordance correlation] = 0.96) with Roche on clinical specimens and increased variability (pc = 0.73) in the range of <3.0 log copies/ml range with the HIV Quant whole-blood assay. HIV Quant plasma assay had good linearity (2.0 to 5.0 log copies/ml; R2 = 0.99). Clinical sensitivity at a viral load of 1,000 copies/ml of the HIV Quant plasma and whole-blood assays compared to that of the Roche assay (n = 94) was 100% (confidence interval [CI], 95.3% to 100%). The specificity of HIV Quant plasma was 88.2% (CI, 63.6% to 98.5%), and that for whole blood was 41.2% (CI, 18.4% to 67.1%). No virological failure (downward misclassification) was missed. Liat HIV Quant plasma assay can be interchanged with existing VL technology in South Africa. Liat HIV Quant whole-blood assay would be advantageous for POC early infant diagnosis at birth and adult adherence monitoring and needs to be evaluated further in this clinical context. LIAT cartridges currently require cold storage, but the technology is user-friendly and robust. Clinical cost and implementation modeling is required. PMID:25740777

  5. Molecular sensitivity threshold of wet mount and an immunochromatographic assay evaluated by quantitative real-time PCR for diagnosis of Trichomonas vaginalis infection in a low-risk population of childbearing women.

    PubMed

    Leli, Christian; Castronari, Roberto; Levorato, Lucia; Luciano, Eugenio; Pistoni, Eleonora; Perito, Stefano; Bozza, Silvia; Mencacci, Antonella

    2016-06-01

    Vaginal trichomoniasis is a sexually transmitted infection caused by Trichomonas vaginalis, a flagellated protozoan. Diagnosis of T. vaginalis infection is mainly performed by wet mount microscopy, with a sensitivity ranging from 38% to 82%, compared to culture, still considered the gold standard. Commercial immunochromatographic tests for monoclonal-antibody-based detection have been introduced as alternative methods for diagnosis of T. vaginalis infection and have been reported in some studies to be more sensitive than wet mount. Real-time PCR methods have been recently developed, with optimal sensitivity and specificity. The aim of this study was to evaluate whether there is a molecular sensitivity threshold for both wet mount and imunochromatographic assays. To this aim, a total of 1487 low-risk childbearing women (median age 32 years, interquartile range 27-37) were included in the study, and underwent vaginal swab for T. vaginalis detection by means of a quantitative real-time PCR assay, wet mount and an immunochromatographic test. Upon comparing the results, prevalence values observed were 1.3% for real-time PCR, 0.5% for microscopic examination, and 0.8% for the immunochromatographic test. Compared to real-time PCR, wet mount sensitivity was 40% (95% confidence interval 19.1% to 63.9%) and specificity was 100% (95% CI 99.7% to 100%). The sensitivity and specificity of the immunochromatographic assay were 57.9% (95% CI 33.5% to 79.8%) and 99.9% (95% CI 99.6% to 100%), respectively. Evaluation of the wet mount results and those of immunochromatographic assay detection in relation to the number of T. vaginalis DNA copies detected in vaginal samples showed that the lower identification threshold for both wet mount (chi-square 6.1; P = 0.016) and the immunochromatographic assay (chi-square 10.7; P = 0.002) was ≥100 copies of T. vaginalis DNA/5 mcl of eluted DNA.

  6. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    PubMed Central

    2009-01-01

    Background Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Methods Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1–2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold™ HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Results Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1–100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2–99.9) and 97.7% (95% CI; 95.7–98.9), respectively, which increased to 100% (95% CI; 99.1–100) on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6–100) while specificities were 99.6% (95% CI; 99–99.9), 99.4% (95% CI; 98.8–99.7), 99.6% (95% CI; 99–99.9) and 99.8% (95% CI; 99.3–99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold™, Determine and SD Bioline assays. Conclusion An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1–100) and 100% specificity (95% CI; 96–99.1) with Uni-Gold™ as tiebreaker for discordant results. PMID:19226452

  7. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania.

    PubMed

    Lyamuya, Eligius F; Aboud, Said; Urassa, Willy K; Sufi, Jaffer; Mbwana, Judica; Ndugulile, Faustin; Massambu, Charles

    2009-02-18

    Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Five rapid HIV assays: Determine HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9), respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold, Determine and SD Bioline assays. An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1-100) and 100% specificity (95% CI; 96-99.1) with Uni-Gold as tiebreaker for discordant results.

  8. Evaluation of a latex agglutination assay for the identification of Burkholderia pseudomallei and Burkholderia mallei.

    PubMed

    Duval, Brea D; Elrod, Mindy G; Gee, Jay E; Chantratita, Narisara; Tandhavanant, Sarunporn; Limmathurotsakul, Direk; Hoffmaster, Alex R

    2014-06-01

    Cases of melioidosis and glanders are rare in the United States, but the etiologic agents of each disease (Burkholderia pseudomallei and Burkholderia mallei, respectively) are classified as Tier 1 select agents because of concerns about their potential use as bioterrorism agents. A rapid, highly sensitive, and portable assay for clinical laboratories and field use is required. Our laboratory has further evaluated a latex agglutination assay for its ability to identify B. pseudomallei and B. mallei isolates. This assay uses a monoclonal antibody that specifically recognizes the capsular polysaccharide produced by B. pseudomallei and B. mallei, but is absent in closely related Burkholderia species. A total of 110 B. pseudomallei and B. mallei were tested, and 36 closely related Burkholderia species. The latex agglutination assay was positive for 109 of 110 (99.1% sensitivity) B. pseudomallei and B. mallei isolates tested. © The American Society of Tropical Medicine and Hygiene.

  9. Evaluation of the Clinical Performance of the HPV-Risk Assay Using the VALGENT-3 Panel.

    PubMed

    Polman, N J; Oštrbenk, A; Xu, L; Snijders, P J F; Meijer, C J L M; Poljak, M; Heideman, D A M; Arbyn, M

    2017-12-01

    Human papillomavirus (HPV) testing is increasingly being incorporated into cervical cancer screening. The Validation of HPV Genotyping Tests (VALGENT) is a framework designed to evaluate the clinical performance of various HPV tests relative to that of the validated and accepted comparator test in a formalized and uniform manner. The aim of this study was to evaluate the clinical performance of the HPV-Risk assay with samples from the VALGENT-3 panel and to compare its performance to that of the clinically validated Hybrid Capture 2 assay (HC2). The VALGENT-3 panel comprises 1,300 consecutive samples from women participating in routine cervical cancer screening and is enriched with 300 samples from women with abnormal cytology. DNA was extracted from original ThinPrep PreservCyt medium aliquots, and HPV testing was performed using the HPV-Risk assay by investigators blind to the clinical data. HPV prevalence was analyzed, and the clinical performance of the HPV-Risk assay for the detection of cervical intraepithelial neoplasia grade 3 or worse (CIN3+) and CIN2 or worse (CIN2+) relative to the performance of HC2 was assessed. The sensitivity of the HPV-Risk assay for the detection of CIN3+ was similar to that of HC2 (relative sensitivity, 1.00; 95% confidence interval [CI], 0.95 to 1.05; P = 1.000), but the specificity of the HPV-Risk assay was significantly higher than that of HC2 (relative specificity, 1.02; 95% CI, 1.01 to 1.04; P < 0.001). For the detection of CIN2+, similar results were obtained, with the relative sensitivity being 0.98 (95% CI, 0.93 to 1.02; P = 0.257) and the relative specificity being 1.02 (95% CI, 1.01 to 1.03; P < 0.001). The performance of the HPV-Risk assay for the detection of CIN3+ and CIN2+ was noninferior to that of HC2, with all P values being ≤0.006. In conclusion, the HPV-Risk assay demonstrated noninferiority to the clinically validated HC2 by the use of samples from the VALGENT-3 panel for test validation and comparison. Copyright © 2017 Polman et al.

  10. Evaluation of GeneXpert MTB/RIF for detecting Mycobacterium tuberculosis in a hospital in China.

    PubMed

    Tang, Tingyu; Liu, Fang; Lu, Xiaoling; Huang, Qingdong

    2017-04-01

    Objective To evaluate the performance of GeneXpert MTB/RIF in diagnosing pulmonary tuberculosis (TB) in China. Methods This cross-sectional study included sputum specimens of 240 suspected TB cases. Specimens were examined by light microscopy for the presence of acid-fast bacilli, which were cultured by the BACTEC MGIT 960 (M960) system and detected by the GeneXpert MTB/RIF assay. The positive rate, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and average turnaround time of methods were evaluated. Results The positive rate was 36.6% (87/238) for the GeneXpert MTB/RIF assay and 34.0% (81/238) by M960 culture, with no significant difference between methods (χ 2  = 0.33, p > 0.05). According to culture results, sensitivity of the GeneXpert MTB/RIF assay was 84.0% (68/81), specificity was 87.8% (129/147), the PPV was 78.2% (68/87), and the NPV was 87.2% (129/148). The agreement for results between Gene Xpert MTB/RIF and the M960 system was 82.8% and the Kappa value was 0.73. Conclusion The GeneXpert MTB/RIF assay is a simple, rapid, and accurate test for detecting Mycobacterium tuberculosis in sputum specimens.

  11. High avidity anti-integrase antibodies discriminate recent and non-recent HIV infection: Implications for HIV incidence assay.

    PubMed

    Rikhtegaran Tehrani, Zahra; Azadmanesh, Kayhan; Mostafavi, Ehsan; Gharibzadeh, Safoora; Soori, Shahrzad; Azizi, Mohammad; Khabiri, Alireza

    2018-03-01

    Estimation of HIV incidence provides real-time information of HIV transmission trends for decision makers. Anti-integrase antibodies are the last ones produced during seroconversion and presence of high-avidity anti-integrase antibodies indicates the chronicity of HIV infection. This study aimed to evaluate the performance of these antibodies in discriminating of recent from non-recent HIV infection. For this purpose, different ELISA formats were developed to detect high-avidity anti-integrase antibodies in a commercially available performance panel, and the best assay was selected for further evaluation. The false recent rate of the selected assay was evaluated in a panel of Iranian patients and compared to two commercial assays, BED-EIA and LAg-Avidity. While the false recent rate of the developed assay was 3.8%, it was 14.1% and 1.3% for BED-EIA and LAg-Avidity, respectively. To our knowledge, this is the first report to study the performance of high-avidity anti-integrase antibodies for classification of HIV infection. The preliminary results showed that the specificity of the newly developed assay is markedly higher than BED-EIA and is comparable with LAg-Avidity. The promising results point to the potential use of anti-integrase antibodies as a biomarker in HIV incidence laboratory tests or algorithms. The developed assay needs further evaluation in future. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Development and validation of a multiplex PCR for detection of Scedosporium spp. in respiratory tract specimens from patients with cystic fibrosis.

    PubMed

    Harun, Azian; Blyth, Christopher C; Gilgado, Felix; Middleton, Peter; Chen, Sharon C-A; Meyer, Wieland

    2011-04-01

    The emergence of Scedosporium infections in diverse groups of individuals, which are often treatment refractory, warrants timely and accurate laboratory diagnosis. Species- or group-specific primers based on internal transcribed spacer (ITS) sequence polymorphisms were designed for Scedosporium aurantiacum, Scedosporium dehoogii, Scedosporium prolificans, Pseudallescheria boydii species complex (former clade 5)/Pseudallescheria apiosperma (formerly classified as S. apiospermum sensu lato) and Pseudallescheria minutispora. Primers for S. aurantiacum, S. prolificans, and P. boydii species complex/P. apiosperma were incorporated into a multiplex PCR assay for the detection and identification of the three major clinically important Scedosporium species and validated using sputum specimens collected from patients seen at a major Australian cystic fibrosis clinic. The multiplex PCR assay showed 100% specificity in identifying the three major clinically relevant Scedosporium species from pure culture. When evaluated using DNA extracts from sputa, sensitivity and specificity of the multiplex PCR assay were 62.1% and 97.2%, respectively. This highly species-specific multiplex PCR assay offers a rapid and simple method of detection of the most clinically important Scedosporium species in respiratory tract specimens.

  13. Fluorometric assay for phenotypic differentiation of drug-resistant HIV mutants

    PubMed Central

    Zhu, Qinchang; Yu, Zhiqiang; Kabashima, Tsutomu; Yin, Sheng; Dragusha, Shpend; El-Mahdy, Ahmed F. M.; Ejupi, Valon; Shibata, Takayuki; Kai, Masaaki

    2015-01-01

    Convenient drug-resistance testing of viral mutants is indispensable to effective treatment of viral infection. We developed a novel fluorometric assay for phenotypic differentiation of drug-resistant mutants of human immunodeficiency virus-I protease (HIV-PR) which uses enzymatic and peptide-specific fluorescence (FL) reactions and high-performance liquid chromatography (HPLC) of three HIV-PR substrates. This assay protocol enables use of non-purified enzyme sources and multiple substrates for the enzymatic reaction. In this study, susceptibility of HIV mutations to drugs was evaluated by selective formation of three FL products after the enzymatic HIV-PR reaction. This proof-of-concept study indicates that the present HPLC-FL method could be an alternative to current phenotypic assays for the evaluation of HIV drug resistance. PMID:25988960

  14. Detection of Rickettsia rickettsii, Rickettsia parkeri, and Rickettsia akari in skin biopsy specimens using a multiplex real-time polymerase chain reaction assay.

    PubMed

    Denison, Amy M; Amin, Bijal D; Nicholson, William L; Paddock, Christopher D

    2014-09-01

    Rickettsia rickettsii, Rickettsia parkeri, and Rickettsia akari are the most common causes of spotted fever group rickettsioses indigenous to the United States. Infected patients characteristically present with a maculopapular rash, often accompanied by an inoculation eschar. Skin biopsy specimens are often obtained from these lesions for diagnostic evaluation. However, a species-specific diagnosis is achieved infrequently from pathologic specimens because immunohistochemical stains do not differentiate among the causative agents of spotted fever group rickettsiae, and existing polymerase chain reaction (PCR) assays generally target large gene segments that may be difficult or impossible to obtain from formalin-fixed tissues. This work describes the development and evaluation of a multiplex real-time PCR assay for the detection of these 3 Rickettsia species from formalin-fixed, paraffin-embedded (FFPE) skin biopsy specimens. The multiplex PCR assay was specific at discriminating each species from FFPE controls of unrelated bacterial, viral, protozoan, and fungal pathogens that cause skin lesions, as well as other closely related spotted fever group Rickettsia species. This multiplex real-time PCR demonstrates greater sensitivity than nested PCR assays in FFPE tissues and provides an effective method to specifically identify cases of Rocky Mountain spotted fever, rickettsialpox, and R. parkeri rickettsiosis by using skin biopsy specimens. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  15. Clinical validation of a highly sensitive assay to detect EGFR mutations in plasma cell-free DNA from patients with advanced lung adenocarcinoma.

    PubMed

    Li, Yuping; Xu, Hanyan; Su, Shanshan; Ye, Junru; Chen, Junjie; Jin, Xuru; Lin, Quan; Zhang, Dongqing; Ye, Caier; Chen, Chengshui

    2017-01-01

    Circulating tumor DNA (ctDNA) is a promising biomarker for noninvasive epidermal growth factor receptor (EGFR) mutations detection in lung cancer patients, but the existing methods have limitations in sensitivity or in availability. In this study, we evaluated the performance of a novel assay called ADx-SuperARMS in detecting EGFR mutations in plasma cell-free DNA from patients with advanced lung adenocarcinoma. A total of 109 patients with metastatic advanced adenocarcinoma were recruited who provided both blood samples and matched tumor tissue samples. EGFR mutation status in plasma samples were tested with ADx-SuperARMS EGFR assay and tumor tissue samples were tested with ADx-ARMS EGFR assay. The clinical sensitivity, specificity, positive prediction value (PPV), and negative prediction value (NPV) of ADx-SuperARMS EGFR assay were calculated by using EGFR mutation status in tumor tissue as standard reference. A receiver operating characteristic (ROC) analysis was implemented and an area under the curve (AUC) was calculated to evaluate sensitivity and specificity of exon 19 deletion (E19Del) and L858R mutation detection. The objective response rate (ORR) were calculated according to the EGFR mutation status determined by ADx-superARMS as well. 0.2% analytical sensitivity and 100% specificity of the ADx-SuperARMS EGFR assays for EGFR E19Del, L858R, and T790M mutants were confirmed by using a series of diluted cell line DNA. In the clinical study, EGFR mutations were detected in 45.9% (50/109) of the plasma samples and in 56.9% (62/109) of the matched tumor tissue samples. The sensitivity, specificity, PPV and NPV of the ADx-SuperARMS EGFR assay for plasma EGFR mutation detection were 82.0% (50/61), 100% (48/48), 100% (50/50), and 81.4% (48/59), respectively. In ROC analysis, ADx-SuperARMS achieved sensitivity and specificity of 88% and 99% in E19Dels as well as sensitivity and specificity of 89% and 100% in L858R, respectively. Among the 35 patients who were plasma EGFR mutation positive and treated with first generation of EGFR-tyrosine kinase inhibitors (TKIs), 23 (65.7%) achieved partial response, 11 (31.4%) sustained disease, and 1 (2.9%) progressive disease. The ORR and disease control rate (DCR) were 65.7% and 97.1%, respectively. ADx-SuperARMS EGFR assay is likely to be a highly sensitive and specific method to noninvasively detect plasma EGFR mutations of patients with advanced lung adenocarcinoma. The EGFR mutations detected by ADx-SuperARMS EGFR assay could predict the efficacy of the treatment with first generation of EGFR-TKIs. Hence, EGFR blood testing with ADx-SuperARMS could address the unmet clinical needs.

  16. [Development and application of CK-MB specific monoclonal antibodies].

    PubMed

    Chen, Zimin; Zhou, Guoliang; Xu, Weiling; Zheng, Xiaohong; Tong, Xunzhang; Ke, Qishen; Song, Liuwei; Ge, Shengxiang

    2017-01-25

    The aim of this study is to develop creatine kinase isoenzyme MB (CK-MB) specific monoclonal antibodies (mAb), and characterize the monoclonal antibody and further development of quantitative detection assay for CK-MB. The BALB/c mice were immunized with purchased CK-MB antigen, then monoclonal antibodies were prepared according to conventional hybridoma technique and screened by indirect and capture ELISA method. To identify the epitopes and evaluate the classification, purchased creatine kinase isoenzyme MB (CK-MM/BB/MB) antigen was used to identify the epitopes, with immunoblotting and synthetic CK-MM and CK-BB in different linear epitope. A double antibody sandwich ELISA was applied to screen the mAb pairs for CK-MB detection, and the quantitative detection assay for CK-MB was developed. We used 74 cases of clinical specimens for comparison of our assay with Roche's CK-MB assay. We successfully developed 22 strains of hybridoms against CK-MB, these mAbs can be divided into linear, partial conformational CK-MB, CK-MM or CK-BB cross monoclonal antibody and CK-MB specific reaction with partial conformational monoclonal antibody, and CK-MB quantitative detection assay was developed by using partial conformational monoclonal antibody. The correlation coefficient factor r of our reagent and Roche's was 0.930 9. This study established a screening method for CK-MB partial conformational specific monoclonal antibody, and these monoclonal antibodies were analyzed and an established quantitative detection assay was developed. The new assay had a high concordance with Roche's.

  17. Genetic point-of-care diagnosis of Mycoplasma pneumoniae infection using LAMP assay.

    PubMed

    Kakuya, Fujio; Kinebuchi, Takahiro; Fujiyasu, Hiroaki; Tanaka, Ryosuke; Kano, Hiroki

    2014-08-01

    Mycoplasma pneumoniae (MP) is a major pathogen of lower respiratory tract infection (LRTI) in children. A rapid diagnostic method during the acute phase is required for the prescription of effective antibiotics. A prospective, single-centered study was conducted on community-acquired LRTI in children. We regarded the day of fever onset as the first day of illness. In part 1, we studied 191 patients with signs of LRTI. We compared diagnostic reliability using loop-mediated isothermal amplification (LAMP) assay and serological testing at the first visit. In part 2, we evaluated the clinical characteristics of 117 patients with positive LAMP assay. In part 1, 31 patients met the definite MP infection criteria. LAMP assay had a sensitivity of 96.8% and specificity of 100%, whereas enzyme immunoassay had a sensitivity of 38.7% and specificity of 76.9%, and particle agglutination test had a sensitivity of 19.4% and specificity of 93.1%. In part 2, of 106 patients with fever, 100 patients were diagnosed by the day 7 of illness. The diagnosis was made a mean of 3.5 ± 2.1 days after the onset of fever. LAMP assay had excellent sensitivity and specificity for the detection of acute MP infection at the first visit. This assay can diagnose MP infection during the very acute phase. LAMP assay is appropriate for genetic point-of-care diagnosis of MP infection in hospital laboratories. © 2014 Japan Pediatric Society.

  18. Testing for developmental neurotoxicity using a battery of in vitro assays for key cellular events in neurodevelopment.

    PubMed

    Harrill, Joshua A; Freudenrich, Theresa; Wallace, Kathleen; Ball, Kenneth; Shafer, Timothy J; Mundy, William R

    2018-04-05

    Medium- to high-throughput in vitro assays that recapitulate the critical processes of nervous system development have been proposed as a means to facilitate rapid testing and identification of chemicals which may affect brain development. In vivo neurodevelopment is a complex progression of distinct cellular processes. Therefore, batteries of in vitro assays that model and quantify effects on a variety of neurodevelopmental processes have the potential to identify chemicals which may affect brain development at different developmental stages. In the present study, the results of concentration-response screening of 67 reference chemicals in a battery of high content imaging and microplate reader-based assays that evaluate neural progenitor cell proliferation, neural proginitor cell apoptosis, neurite initiation/outgrowth, neurite maturation and synaptogenesis are summarized and compared. The assay battery had a high degree of combined sensitivity (87%) for categorizing chemicals known to affect neurodevelopment as active and a moderate degree of combined specificity (71%) for categorizing chemicals not associated with affects on neurodevelopment as inactive. The combined sensitivity of the assay battery was higher compared to any individual assay while the combined specificity of the assay battery was lower compared to any individual assay. When selectivity of effects for a neurodevelopmental endpoint as compared to general cytotoxicity was taken into account, the combined sensitivity of the assay battery decreased (68%) while the combined specificity increased (93%). The identity and potency of chemicals identified as active varied across the assay battery, underscoring the need for use of a combination of diverse in vitro models to comprehensively screen chemicals and identify those which potentially affect neurodevelopment. Overall, these data indicate that a battery of assays which address many different processes in nervous system development may be used to identify potential developmental neurotoxicants and to distinguish specific from generalized cytotoxic effects with a high degree of success. Published by Elsevier Inc.

  19. Evaluation of a real-time polymerase chain reaction assay of the outer membrane protein P2 gene for the detection of Haemophilus parasuis in clinical samples.

    PubMed

    McDowall, Rebeccah; Slavic, Durda; MacInnes, Janet I; Cai, Hugh Y

    2014-04-01

    A real-time polymerase chain reaction (PCR) assay of the outer membrane protein (OMP) P2 gene was developed and used to test 97 putative Haemophilus parasuis pure cultures and 175 clinical tissue samples. With standard culture isolation as the gold standard, the diagnostic sensitivity and specificity of the PCR assay were determined to be 83% and 80%, respectively.

  20. Evaluation of a real-time polymerase chain reaction assay of the outer membrane protein P2 gene for the detection of Haemophilus parasuis in clinical samples

    PubMed Central

    McDowall, Rebeccah; Slavic, Durda; MacInnes, Janet I.; Cai, Hugh Y.

    2014-01-01

    A real-time polymerase chain reaction (PCR) assay of the outer membrane protein (OMP) P2 gene was developed and used to test 97 putative Haemophilus parasuis pure cultures and 175 clinical tissue samples. With standard culture isolation as the gold standard, the diagnostic sensitivity and specificity of the PCR assay were determined to be 83% and 80%, respectively. PMID:24688178

  1. Evaluation of a PCR/ESI-MS platform to identify respiratory viruses from nasopharyngeal aspirates.

    PubMed

    Lin, Yong; Fu, Yongfeng; Xu, Menghua; Su, Liyun; Cao, Lingfeng; Xu, Jin; Cheng, Xunjia

    2015-11-01

    Acute respiratory tract infection is a major cause of morbidity and mortality worldwide, particularly in infants and young children. High-throughput, accurate, broad-range tools for etiologic diagnosis are critical for effective epidemic control. In this study, the diagnostic capacities of an Ibis platform based on the PCR/ESI-MS assay were evaluated using clinical samples. Nasopharyngeal aspirates (NPAs) were collected from 120 children (<5 years old) who were hospitalized with lower respiratory tract infections between November 2010 and October 2011. The respiratory virus detection assay was performed using the PCR/ESI-MS assay and the DFA. The discordant PCR/ESI-MS and DFA results were resolved with RT-PCR plus sequencing. The overall agreement for PCR/ESI-MS and DFA was 98.3% (118/120). Compared with the results from DFA, the sensitivity and specificity of the PCR/ESI-MS assay were 100% and 97.5%, respectively. The PCR/ESI-MS assay also detected more multiple virus infections and revealed more detailed subtype information than DFA. Among the 12 original specimens with discordant results between PCR/ESI-MS and DFA, 11 had confirmed PCR/ESI-MS results. Thus, the PCR/ESI-MS assay is a high-throughput, sensitive, specific and promising method to detect and subtype conventional viruses in respiratory tract infections and allows rapid identification of mixed pathogens. © 2015 Wiley Periodicals, Inc.

  2. Development and evaluation of a loop-mediated isothermal amplification assay for rapid detection of lymphocystis disease virus.

    PubMed

    Li, Qiong; Yue, Zhiqin; Liu, Hong; Liang, Chengzhu; Zheng, Xiaolong; Zhao, Yuran; Chen, Xiao; Xiao, Xizhi; Chen, Changfu

    2010-02-01

    A loop-mediated isothermal amplification (LAMP) assay was developed for the detection of lymphocystis disease virus (LCDV). A set of five specific primers, two inner and two outer primers and a loop primer, were designed on the basis of the major capsid protein gene of LCDV. The reaction time and temperatures were optimized for 60 min at 63 degrees C, respectively. LAMP amplification products were detected by a ladder-like appearance on agarose gel electrophoresis or a naked-eye inspection of a color change in the reaction tube by addition of SYBR Green I. The assay was specific for LCDV, and there was no cross-reactivity with white spot syndrome virus (WSSV) or six other Iridoviridae viruses (epizootic hematopoietic necrosis virus, EHNV; tiger frog virus, TFV; Bohle iridovirus, BIV; soft-shelled turtle iridovirus, STIV; infectious spleen and kidney necrosis virus, ISKNV; red sea bream iridovirus, RSIV). The detection limit of the LAMP assay was 15 fg, which was similar to that of real-time quantitative polymerase chain reaction (PCR) and 10-fold higher than the conventional PCR. The LAMP assay was evaluated using 109 clinical samples, and the results indicated the suitability and simplicity of the test as a rapid, field diagnostic tool for detection of LCDV. The LCDV LAMP assay has potential for early diagnosis of LCDV infection. 2009 Elsevier B.V. All rights reserved.

  3. Development and validation of a real-time PCR assay for specific and sensitive detection of canid herpesvirus 1.

    PubMed

    Decaro, Nicola; Amorisco, Francesca; Desario, Costantina; Lorusso, Eleonora; Camero, Michele; Bellacicco, Anna Lucia; Sciarretta, Rossana; Lucente, Maria Stella; Martella, Vito; Buonavoglia, Canio

    2010-10-01

    A TaqMan-based real-time PCR assay targeting the glycoprotein B-encoding gene was developed for diagnosis of canid herpesvirus 1 (CHV-1) infection. The established assay was highly specific, since no cross-reactions were observed with other canine DNA viruses, including canine parvovirus type 2, canine minute virus, or canine adenovirus types 1 and 2. The detection limit was 10(1) and 1.20 x 10(1) DNA copies per 10 microl(-1) of template for standard DNA and a CHV-1-positive kidney sample, respectively: about 1-log higher than a gel-based PCR assay targeting the thymidine kinase gene. The assay was also reproducible, as shown by satisfactory low intra-assay and inter-assay coefficients of variation. CHV-1 isolates of different geographical origins were recognised by the TaqMan assay. Tissues and clinical samples collected from three pups which died of CHV-1 neonatal infection were also tested, displaying a wide distribution of CHV-l DNA in their organs. Unlike other CHV-1-specific diagnostic methods, this quantitative assay permits simultaneous detection and quantitation of CHV-1 DNA in a wide range of canine tissues and body fluids, thus providing a useful tool for confirmation of a clinical diagnosis, for the study of viral pathogenesis and for evaluation of the efficacy of vaccines and antiviral drugs. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  4. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident

    PubMed Central

    Semenova, Vera A.; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r2), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from −4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r2 = 0.952, slope = 1.02 and intercept = −0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. PMID:27814939

  5. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident.

    PubMed

    Semenova, Vera A; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r 2 ), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from -4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r 2  = 0.952, slope = 1.02 and intercept = -0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. Published by Elsevier Ltd.

  6. Advanced yellow fever virus genome detection in point-of-care facilities and reference laboratories.

    PubMed

    Domingo, Cristina; Patel, Pranav; Yillah, Jasmin; Weidmann, Manfred; Méndez, Jairo A; Nakouné, Emmanuel Rivalyn; Niedrig, Matthias

    2012-12-01

    Reported methods for the detection of the yellow fever viral genome are beset by limitations in sensitivity, specificity, strain detection spectra, and suitability to laboratories with simple infrastructure in areas of endemicity. We describe the development of two different approaches affording sensitive and specific detection of the yellow fever genome: a real-time reverse transcription-quantitative PCR (RT-qPCR) and an isothermal protocol employing the same primer-probe set but based on helicase-dependent amplification technology (RT-tHDA). Both assays were evaluated using yellow fever cell culture supernatants as well as spiked and clinical samples. We demonstrate reliable detection by both assays of different strains of yellow fever virus with improved sensitivity and specificity. The RT-qPCR assay is a powerful tool for reference or diagnostic laboratories with real-time PCR capability, while the isothermal RT-tHDA assay represents a useful alternative to earlier amplification techniques for the molecular diagnosis of yellow fever by field or point-of-care laboratories.

  7. Comparison of real-time PCR methods for the detection of Naegleria fowleri in surface water and sediment.

    PubMed

    Streby, Ashleigh; Mull, Bonnie J; Levy, Karen; Hill, Vincent R

    2015-05-01

    Naegleria fowleri is a thermophilic free-living ameba found in freshwater environments worldwide. It is the cause of a rare but potentially fatal disease in humans known as primary amebic meningoencephalitis. Established N. fowleri detection methods rely on conventional culture techniques and morphological examination followed by molecular testing. Multiple alternative real-time PCR assays have been published for rapid detection of Naegleria spp. and N. fowleri. Foursuch assays were evaluated for the detection of N. fowleri from surface water and sediment. The assays were compared for thermodynamic stability, analytical sensitivity and specificity, detection limits, humic acid inhibition effects, and performance with seeded environmental matrices. Twenty-one ameba isolates were included in the DNA panel used for analytical sensitivity and specificity analyses. N. fowleri genotypes I and III were used for method performance testing. Two of the real-time PCR assays were determined to yield similar performance data for specificity and sensitivity for detecting N. fowleri in environmental matrices.

  8. Comparison of real-time PCR methods for the detection of Naegleria fowleri in surface water and sediment

    PubMed Central

    Streby, Ashleigh; Mull, Bonnie J.; Levy, Karen

    2015-01-01

    Naegleria fowleri is a thermophilic free-living ameba found in freshwater environments worldwide. It is the cause of a rare but potentially fatal disease in humans known as primary amebic meningoencephalitis. Established N. fowleri detection methods rely on conventional culture techniques and morphological examination followed by molecular testing. Multiple alternative real-time PCR assays have been published for rapid detection of Naegleria spp. and N. fowleri. Four such assays were evaluated for the detection of N. fowleri from surface water and sediment. The assays were compared for thermodynamic stability, analytical sensitivity and specificity, detection limits, humic acid inhibition effects, and performance with seeded environmental matrices. Twenty-one ameba isolates were included in the DNA panel used for analytical sensitivity and specificity analyses. N. fowleri genotypes I and III were used for method performance testing. Two of the real-time PCR assays were determined to yield similar performance data for specificity and sensitivity for detecting N. fowleri in environmental matrices. PMID:25855343

  9. A sensitive epitope-blocking ELISA for the detection of Chikungunya virus-specific antibodies in patients.

    PubMed

    Goh, Lucas Y H; Kam, Yiu-Wing; Metz, Stefan W; Hobson-Peters, Jody; Prow, Natalie A; McCarthy, Suzi; Smith, David W; Pijlman, Gorben P; Ng, Lisa F P; Hall, Roy A

    2015-09-15

    Chikungunya fever (CHIKF) has re-emerged as an arboviral disease that mimics clinical symptoms of other diseases such as dengue, malaria, as well as other alphavirus-related illnesses leading to problems with definitive diagnosis of the infection. Herein we describe the development and evaluation of a sensitive epitope-blocking ELISA (EB-ELISA) capable of specifically detecting anti-chikungunya virus (CHIKV) antibodies in clinical samples. The assay uses a monoclonal antibody (mAb) that binds an epitope on the E2 protein of CHIKV and does not exhibit cross-reactivity to other related alphaviruses. We also demonstrated the use of recombinant CHIK virus-like particles (VLPs) as a safe alternative antigen to infectious virions in the assay. Based on testing of 60 serum samples from patients in the acute or convalescent phase of CHIKV infection, the EB-ELISA provided us with 100% sensitivity, and exhibited 98.5% specificity when Ross River virus (RRV)- or Barmah Forest virus (BFV)-immune serum samples were included. This assay meets the public health demands of a rapid, robust, sensitive and specific, yet simple assay for specifically diagnosing CHIK-infections in humans. Copyright © 2015. Published by Elsevier B.V.

  10. Development and Evaluation of Novel Real-Time Reverse Transcription-PCR Assays with Locked Nucleic Acid Probes Targeting Leader Sequences of Human-Pathogenic Coronaviruses

    PubMed Central

    Chan, Jasper Fuk-Woo; Choi, Garnet Kwan-Yue; Tsang, Alan Ka-Lun; Tee, Kah-Meng; Lam, Ho-Yin; Yip, Cyril Chik-Yan; To, Kelvin Kai-Wang; Cheng, Vincent Chi-Chung; Yeung, Man-Lung; Lau, Susanna Kar-Pui; Woo, Patrick Chiu-Yat; Chan, Kwok-Hung; Tang, Bone Siu-Fai

    2015-01-01

    Based on findings in small RNA-sequencing (Seq) data analysis, we developed highly sensitive and specific real-time reverse transcription (RT)-PCR assays with locked nucleic acid probes targeting the abundantly expressed leader sequences of Middle East respiratory syndrome coronavirus (MERS-CoV) and other human coronaviruses. Analytical and clinical evaluations showed their noninferiority to a commercial multiplex PCR test for the detection of these coronaviruses. PMID:26019210

  11. Diagnostic value of animal-side antibody assays for rapid detection of Mycobacterium bovis or Mycobacterium microti infection in South American camelids.

    PubMed

    Lyashchenko, Konstantin P; Greenwald, Rena; Esfandiari, Javan; Rhodes, Shelley; Dean, Gillian; de la Rua-Domenech, Ricardo; Meylan, Mireille; Vordermeier, H Martin; Zanolari, Patrik

    2011-12-01

    Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB.

  12. Diagnostic Value of Animal-Side Antibody Assays for Rapid Detection of Mycobacterium bovis or Mycobacterium microti Infection in South American Camelids▿

    PubMed Central

    Lyashchenko, Konstantin P.; Greenwald, Rena; Esfandiari, Javan; Rhodes, Shelley; Dean, Gillian; de la Rua-Domenech, Ricardo; Meylan, Mireille; Vordermeier, HMartin; Zanolari, Patrik

    2011-01-01

    Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB. PMID:22012976

  13. Development of simple and rapid assay to detect viral RNA of tick-borne encephalitis virus by reverse transcription-loop-mediated isothermal amplification.

    PubMed

    Hayasaka, Daisuke; Aoki, Kotaro; Morita, Kouichi

    2013-03-04

    Tick-borne encephalitis virus (TBEV) is a causative agent of acute central nervous system disease in humans. It has three subtypes, far eastern (FE), Siberian (Sib) and European (Eu) subtypes, which are distributed over a wide area of Europe and Asia. The objective of this study was to develop a simple and rapid assay for the detection of TBEV RNA by using reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) method that can differentiate the three subtypes of TBEV and can be used for clinical diagnosis and epidemiological study. Primers for TBEV-specific and subtype-specific RT-LAMP assay were designed to target the consensus sequence in NS1 of all subtypes and the consensus sequence in the E gene of each subtype, respectiveluy. In vitro transcribed RNA of Oshima strain that belongs to FE subtype was serially diluted and used to examine the sensitivity of the assay. Cross-reactivity of subtype-specific RT-LAMP assay was tested by using the RNA of Oshima and Sofjin (FE), IR-99 (Sib) and Hochosterwitz (Eu) strains. RNA extracted from the mixtures of TBEV and ticks, and of TBEV and human blood, and the mouse tissues infected with TBEV, were evaluated in the assay. Positive amplification was observed by real-time monitoring of turbidity and by visual detection of color change. The sensitivity of TBEV-specific RT-LAMP assay was 102 copies of target RNA per reaction volume. FE-specific RT-LAMP assay amplified viral genes of Oshima and Sofjin strains but not of IR-99 and Hochosterwitz strains, and of Japanese encephalitis virus. RT-LAMP assay for Sib and for Eu specifically amplified viral genes of IR-99 and Hochosterwitz strains, respectively. We also showed that tick or human blood extract did not inhibit the amplification of viral gene during the assay. Furthermore, we confirmed that the TBEV RT-LAMP could detect virus RNA from peripheral and central nervous system tissues of laboratory mice infected with TBEV. TBEV RT-LAMP assay offers a sensitive, specific, rapid and easy-to-handle method for the detection of TBEV RNA in tick samples and this may be applied in the clinical samples collected from TBE-suspected patients.

  14. Diagnostic accuracy and turnaround time of the Xpert MTB/RIF assay in routine clinical practice.

    PubMed

    Kwak, Nakwon; Choi, Sun Mi; Lee, Jinwoo; Park, Young Sik; Lee, Chang-Hoon; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Yim, Jae-Joon

    2013-01-01

    The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of pulmonary tuberculosis (PTB) and detection of rifampicin resistance were calculated. In addition, TAT of Xpert MTB/RIF assay was compared with those of other tests. Total 681 patients in whom Xpert MTB/RIF assay was requested were included in the analysis. The sensitivity, specificity, PPV and NPV of Xpert MTB/RIF assay for diagnosis of PTB were 79.5% (124/156), 100.0% (505/505), 100.0% (124/124) and 94.0% (505/537), respectively. Those for the detection of rifampicin resistance were 57.1% (8/14), 100.0% (113/113), 100.0% (8/8) and 94.9% (113/119), respectively. The median TAT of Xpert MTB/RIF assay to the report of results and results confirmed by physicians in outpatient settings were 0 (0-1) and 6 (3-7) days, respectively. Median time to treatment after initial evaluation was 7 (4-9) days in patients with Xpert MTB/RIF assay, but was 21 (7-33.5) days in patients without Xpert MTB/RIF assay. Xpert MTB/RIF assay showed acceptable sensitivity and excellent specificity for the diagnosis of PTB and detection of rifampicin resistance in areas with intermediate TB burden. Additionally, the assay decreased time to the initiation of anti-TB drugs through shorter TAT.

  15. Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice

    PubMed Central

    Kwak, Nakwon; Choi, Sun Mi; Lee, Jinwoo; Park, Young Sik; Lee, Chang-Hoon; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Yim, Jae-Joon

    2013-01-01

    The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of pulmonary tuberculosis (PTB) and detection of rifampicin resistance were calculated. In addition, TAT of Xpert MTB/RIF assay was compared with those of other tests. Total 681 patients in whom Xpert MTB/RIF assay was requested were included in the analysis. The sensitivity, specificity, PPV and NPV of Xpert MTB/RIF assay for diagnosis of PTB were 79.5% (124/156), 100.0% (505/505), 100.0% (124/124) and 94.0% (505/537), respectively. Those for the detection of rifampicin resistance were 57.1% (8/14), 100.0% (113/113), 100.0% (8/8) and 94.9% (113/119), respectively. The median TAT of Xpert MTB/RIF assay to the report of results and results confirmed by physicians in outpatient settings were 0 (0–1) and 6 (3–7) days, respectively. Median time to treatment after initial evaluation was 7 (4–9) days in patients with Xpert MTB/RIF assay, but was 21 (7–33.5) days in patients without Xpert MTB/RIF assay. Xpert MTB/RIF assay showed acceptable sensitivity and excellent specificity for the diagnosis of PTB and detection of rifampicin resistance in areas with intermediate TB burden. Additionally, the assay decreased time to the initiation of anti-TB drugs through shorter TAT. PMID:24204834

  16. Differentiation of herpes simplex virus types 1 and 2 in clinical samples by a real-time taqman PCR assay.

    PubMed

    Corey, Lawrence; Huang, Meei-Li; Selke, Stacy; Wald, Anna

    2005-07-01

    While the clinical manifestations of HSV-1 and -2 overlap, the site of CNS infection, complications, response to antivirals, frequency of antiviral resistance, and reactivation rate on mucosal surfaces varies between HSV-1 and -2. Detection of HSV DNA by PCR has been shown to be the most sensitive method for detecting HSV in clinical samples. As such, we developed a PCR-based assay to accurately distinguish HSV-1 from HSV-2. Our initial studies indicated the assay using type specific primers was slightly less efficient for detecting HSV-1 and -2 DNA than the high throughput quantitative PCR assay we utilize that employs type common primers to gB. We subsequently evaluated the type specific assay on 3,131 specimens that had HSV DNA detected in the type common PCR assay. The typing results of these specimens were compared with the monoclonal antibody staining results of culture isolates collected from the same patients at the same time, and the HSV serologic status of the patient. The typing assay accurately identified both HSV-1 and -2 with a specificity of >99.5% and was significantly more sensitive than typing by culture and subsequent monoclonal antibody assays. Complete concordance was seen between the typing assay and HSV serologic status of the patient. Dual (HSV-1 and -2) infection in clinical samples was recognized in 2.6% of clinical samples using the new typing assay. This assay, when used in combination with the type common assay, can now accurately type almost all mucosal and visceral HSV isolates by molecular techniques. Copyright (c) 2005 Wiley-Liss, Inc.

  17. Prostate cancer marker panel with single cell sensitivity in urine.

    PubMed

    Nickens, Kristen P; Ali, Amina; Scoggin, Tatiana; Tan, Shyh-Han; Ravindranath, Lakshmi; McLeod, David G; Dobi, Albert; Tacha, David; Sesterhenn, Isabell A; Srivastava, Shiv; Petrovics, Gyorgy

    2015-06-15

    Over one million men undergo prostate biopsies annually in the United States, a majority of whom due to elevated serum PSA. More than half of the biopsies turn out to be negative for prostate cancer (CaP). The limitations of both the PSA test and the biopsy procedure have led to the development for more precise CaP detection assays in urine (e.g., PCA3, TMPRSS2-ERG) or blood (e.g., PHI, 4K). Here, we describe the development and evaluation of the Urine CaP Marker Panel (UCMP) assay for sensitive and reproducible detection of CaP cells in post-digital rectal examination (post-DRE) urine. The cellular content of the post-DRE urine was captured on a translucent filter membrane, which is placed on Cytoclear slides for direct evaluation by microscopy and immuno-cytochemistry (ICC). Cells captured on the membrane were assayed for PSA and Prostein expression to identify prostate epithelial cells, and for ERG and AMACR to identify prostate tumor cells. Immunostained cells were analyzed for quantitative and qualitative features and correlated with biopsy positive and negative status for malignancy. The assay was optimized for single cell capture sensitivity and downstream evaluations by spiking a known number of cells from established CaP cell lines, LNCaP and VCaP, into pre-cleared control urine. The cells captured from the post-DRE urine of subjects, obtained prior to biopsy procedure, were co-stained for ERG, AMACR (CaP specific), and Prostein or PSA (prostate epithelium specific) rendering a whole cell based analysis and characterization. A feasibility cohort of 63 post-DRE urine specimens was assessed. Comparison of the UCMP results with blinded biopsy results showed an assay sensitivity of 64% (16 of 25) and a specificity of 68.8% (22 of 32) for CaP detection by biopsy. This pilot study assessing a minimally invasive CaP detection assay with single cell sensitivity cell-capture and characterization from the post-DRE urine holds promise for further development of this novel assay platform. Prostate 75: 969-975, 2015. © 2015 The Authors. The Prostate, published by Wiley Periodicals, Inc. © 2015 The Authors. The Prostate, published by Wiley Periodicals, Inc.

  18. Evaluation of the diagnostic value of serologic microagglutination testing and a polymerase chain reaction assay for diagnosis of acute leptospirosis in dogs in a referral center.

    PubMed

    Fraune, Claudia Kümmerle; Schweighauser, Ariane; Francey, Thierry

    2013-05-15

    To determine the diagnostic value of a serologic microagglutination test (MAT) and a PCR assay on urine and blood for the diagnosis of leptospirosis in dogs with acute kidney injury (AKI). Cross-sectional study. Animals-76 dogs with AKI in a referral hospital (2008 to 2009). Dogs' leptospirosis status was defined with a paired serologic MAT against a panel of 11 Leptospira serovars as leptospirosis-associated (n = 30) or nonleptospirosis-associated AKI (12). In 34 dogs, convalescent serologic testing was not possible, and leptospirosis status was classified as undetermined. The diagnostic value of the MAT single acute or convalescent blood sample was determined in dogs in which leptospirosis status could be classified. The diagnostic value of a commercially available genus-specific PCR assay was evaluated by use of 36 blood samples and 20 urine samples. Serologic acute testing of an acute blood sample had a specificity of 100% (95% CI, 76% to 100%), a sensitivity of 50% (33% to 67%), and an accuracy of 64% (49% to 77%). Serologic testing of a convalescent blood sample had a specificity of 92% (65% to 99%), a sensitivity of 100% (87% to 100%), and an accuracy of 98% (88% to 100%). Results of the Leptospira PCR assay were negative for all samples from dogs for which leptospirosis status could be classified. Serologic MAT results were highly accurate for diagnosis of leptospirosis in dogs, despite a low sensitivity for early diagnosis. In this referral setting of dogs pretreated with antimicrobials, testing of blood and urine samples with a commercially available genus-specific PCR assay did not improve early diagnosis.

  19. Detection of Memory B Activity Against a Therapeutic Protein in Treatment-Naïve Subjects.

    PubMed

    Liao, Karen; Derbyshire, Stacy; Wang, Kai-Fen; Caucci, Cherilyn; Tang, Shuo; Holland, Claire; Loercher, Amy; Gunn, George R

    2018-03-16

    Bridging immunoassays commonly used to detect and characterize immunogenicity during biologic development do not provide direct information on the presence or development of a memory anti-drug antibody (ADA) response. In this study, a B cell ELISPOT assay method was used to evaluate pre-existing ADA for anti-TNFR1 domain antibody, GSK1995057, an experimental biologic in treatment naive subjects. This assay utilized a 7-day activation of PBMCs by a combination of GSK1995057 (antigen) and polyclonal stimulator followed by GSK1995057-specific ELISPOT for the enumeration of memory B cells that have differentiated into antibody secreting cells (ASC) in vitro. We demonstrated that GSK1995057-specific ASC were detectable in treatment-naïve subjects with pre-existing ADA; the frequency of drug-specific ASC was low and ranged from 1 to 10 spot forming units (SFU) per million cells. Interestingly, the frequency of drug-specific ASC correlated with the ADA level measured using an in vitro ADA assay. We further confirmed that the ASC originated from CD27 + memory B cells, not from CD27 - -naïve B cells. Our data demonstrated the utility of the B cell ELISPOT method in therapeutic protein immunogenicity evaluation, providing a novel way to confirm and characterize the cell population producing pre-existing ADA. This novel application of a B cell ELISPOT assay informs and characterizes immune memory activity regarding incidence and magnitude associated with a pre-existing ADA response.

  20. Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs.

    PubMed

    Pickering, Harry; Holland, Martin J; Last, Anna R; Burton, Matthew J; Burr, Sarah E

    2018-02-20

    Trachoma, the leading infectious cause of blindness worldwide, is caused by conjunctival Chlamydia trachomatis infection. Trachoma is diagnosed clinically by observation of conjunctival inflammation and/or scarring; however, there is evidence that monitoring C. trachomatis infection may be required for elimination programmes. There are many commercial and 'in-house' nucleic acid amplification tests for the detection of C. trachomatis DNA, but the majority have not been validated for use with ocular swabs. This study evaluated a commercial assay, the Fast-Track Vaginal swab kit, using conjunctival samples from trachoma-endemic areas. An objective, biostatistical-based method for binary classification of continuous PCR data was developed, to limit potential user-bias in diagnostic settings. The Fast-Track Vaginal swab assay was run on 210 ocular swab samples from Guinea-Bissau and Tanzania. Fit of individual amplification curves to exponential or sigmoid models, derivative and second derivative of the curves and final fluorescence value were examined for utility in thresholding for determining positivity. The results from the Fast-Track Vaginal swab assay were evaluated against a commercial test (Amplicor CT/NG) and a non-commercial test (in-house droplet digital PCR), both of whose performance has previously been evaluated. Significant evidence of exponential amplification (R 2  > 0.99) and final fluorescence > 0.15 were combined for thresholding. This objective approach identified a population of positive samples, however there were a subset of samples that amplified towards the end of the cycling protocol (at or later than 35 cycles), which were less clearly defined. The Fast-Track Vaginal swab assay showed good sensitivity against the commercial (95.71) and non-commercial (97.18) tests. Specificity was lower against both (90.00 and 96.55, respectively). This study defined a simple, automated protocol for binary classification of continuous, real-time qPCR data, for use in an end-point diagnostic test. This method identified a population of positive samples, however, as with manual thresholding, a subset of samples that amplified towards the end of the cycling program were less easily classified. When used with ocular swabs, the Fast-Track Vaginal swab assay had good sensitivity for C. trachomatis detection, but lower specificity than the commercial and non-commercial assays it was evaluated against, possibly leading to false positives.

  1. Clover-Tagged Porcine Reproductive and Respiratory Syndrome Virus Infectious Clones for Rapid Detection of Virus Neutralizing Antibodies.

    PubMed

    Huang, Baicheng; Xiao, Xia; Xue, Biyun; Zhou, En-Min

    2018-06-24

    Porcine reproductive and respiratory syndrome (PRRS), caused by the PRRS virus (PRRSV), is a widespread disease that affects domestic pigs of all ages. Accurate and rapid detection of PRRSV specific neutralizing antibodies levels in a pig herd is beneficial for the evaluation of the herd's immunity to combat the specific viral infection. However, the current methods for viral detection, including fluorescent focus neutralization (FFN) and cytopathic effect (CPE) reduction neutralizing assays, are subjective and time-consuming. Therefore, a Clover-tagged PRRSV virus neutralization assay were developed that instrumentally measures the fluorescence signal of Clover stably expressing by a PRRSV infectious clone for at least 10 passages. Herein, the results showed that the proposed Clover-tagged PRRSV neutralization assay is reliable using instrumental measurements of the fluorescence signal of Clover and allows for rapid detection of neutralizing antibodies against PRRSV. The assay was evaluated by testing swine sera from experimental and field samples, and comparisons were made with the traditional FFN and CPE reduction assays. These results suggest that the Clover-tagged PRRSV infectious clone offers a fast and reliable testing method for neutralizing antibodies and could permit high-throughput screening of new antiviral agents. Copyright © 2018. Published by Elsevier B.V.

  2. A versatile transfection assay system to evaluate the biological effects of diverse industrial chemicals.

    PubMed

    Koizumi, Shinji; Ohno, Shotaro; Otsuka, Fuminori

    2012-01-01

    Gene expression processes are now recognized as important targets of the toxic effects exerted by industrial chemicals. The transient transfection assay is a powerful tool to evaluate such effects. Thus, we developed a versatile assay system by constructing a basic reporter plasmid in which the regulatory DNA sequence to be studied can easily be substituted. To verify the performance of this system, reporter plasmids carrying any of the three distinct regulatory sequences, estrogen responsive element (ERE), glucocorticoid responsive element (GRE) and xenobiotic responsive element (XRE) were constructed. After transfection of human cells, these plasmids successfully expressed the relevant reporter genes in response to specific inducers, β-estradiol, dexamethasone and 3-methylcholanthrene, respectively. Several industrial chemicals were assayed using these reporter plasmids, and the ability of p-dimethylaminoazobenzene to elevate GRE- and XRE-mediated transcription was detected. α-Naphthylamine and o-tolidine were also observed to increase the XRE-mediated response. The transfection assay system established here will be useful to evaluate the effects of a wide variety of industrial chemicals.

  3. Statistical evaluation of accelerated stability data obtained at a single temperature. I. Effect of experimental errors in evaluation of stability data obtained.

    PubMed

    Yoshioka, S; Aso, Y; Takeda, Y

    1990-06-01

    Accelerated stability data obtained at a single temperature is statistically evaluated, and the utility of such data for assessment of stability is discussed focussing on the chemical stability of solution-state dosage forms. The probability that the drug content of a product is observed to be within the lower specification limit in the accelerated test is interpreted graphically. This probability depends on experimental errors in the assay and temperature control, as well as the true degradation rate and activation energy. Therefore, the observation that the drug content meets the specification in the accelerated testing can provide only limited information on the shelf-life of the drug, without the knowledge of the activation energy and the accuracy and precision of the assay and temperature control.

  4. Quantitative real-time PCR technique for the identification of E. coli residual DNA in streptokinase recombinant product.

    PubMed

    Fazelahi, Mansoureh; Kia, Vahid; Kaghazian, Hooman; Paryan, Mahdi

    2017-11-26

    Recombinant streptokinase is a biopharmaceutical which is usually produced in E. coli. Residual DNA as a contamination and risk factor may remain in the product. It is necessary to control the production procedure to exclude any possible contamination. The aim of the present study was to develop a highly specific and sensitive quantitative real-time PCR-based method to determine the amount of E. coli DNA in recombinant streptokinase. A specific primers and a probe was designed to detect all strains of E. coli. To determine the specificity, in addition to using NCBI BLASTn, 28 samples including human, bacterial, and viral genomes were used. The results confirmed that the assay detects no genomic DNA but E. coli's and the specificity was determined to be 100%. To determine the sensitivity and limit of detection of the assay, a 10-fold serial dilution (10 1 to 10 7 copies/µL) was tested in triplicate. The sensitivity of the test was determined to be 101 copies/µL or 35 fg/µL. Inter-assay and intra-assay were determined to be 0.86 and 1.69%, respectively. Based on the results, this assay can be used as an accurate method to evaluate the contamination of recombinant streptokinase in E. coli.

  5. Development of Quantitative Real-Time PCR Assays for Detection and Quantification of Surrogate Biological Warfare Agents in Building Debris and Leachate▿

    PubMed Central

    Saikaly, Pascal E.; Barlaz, Morton A.; de los Reyes, Francis L.

    2007-01-01

    Evaluation of the fate and transport of biological warfare (BW) agents in landfills requires the development of specific and sensitive detection assays. The objective of the current study was to develop and validate SYBR green quantitative real-time PCR (Q-PCR) assays for the specific detection and quantification of surrogate BW agents in synthetic building debris (SBD) and leachate. Bacillus atrophaeus (vegetative cells and spores) and Serratia marcescens were used as surrogates for Bacillus anthracis (anthrax) and Yersinia pestis (plague), respectively. The targets for SYBR green Q-PCR assays were the 16S-23S rRNA intergenic transcribed spacer (ITS) region and recA gene for B. atrophaeus and the gyrB, wzm, and recA genes for S. marcescens. All assays showed high specificity when tested against 5 ng of closely related Bacillus and Serratia nontarget DNA from 21 organisms. Several spore lysis methods that include a combination of one or more of freeze-thaw cycles, chemical lysis, hot detergent treatment, bead beat homogenization, and sonication were evaluated. All methods tested showed similar threshold cycle values. The limit of detection of the developed Q-PCR assays was determined using DNA extracted from a pure bacterial culture and DNA extracted from sterile water, leachate, and SBD samples spiked with increasing quantities of surrogates. The limit of detection for B. atrophaeus genomic DNA using the ITS and B. atrophaeus recA Q-PCR assays was 7.5 fg per PCR. The limits of detection of S. marcescens genomic DNA using the gyrB, wzm, and S. marcescens recA Q-PCR assays were 7.5 fg, 75 fg, and 7.5 fg per PCR, respectively. Quantification of B. atrophaeus vegetative cells and spores was linear (R2 > 0.98) over a 7-log-unit dynamic range down to 101 B. atrophaeus cells or spores. Quantification of S. marcescens (R2 > 0.98) was linear over a 6-log-unit dynamic range down to 102 S. marcescens cells. The developed Q-PCR assays are highly specific and sensitive and can be used for monitoring the fate and transport of the BW surrogates B. atrophaeus and S. marcescens in building debris and leachate. PMID:17720820

  6. Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays.

    PubMed

    Pannus, Pieter; Claus, Maarten; Gonzalez, Maria Mercedes Perez; Ford, Nathan; Fransen, Katrien

    2016-11-01

    The use of dried blood spots (DBS) instead of plasma as a specimen type for HIV-1 viral load (VL) testing facilitates the decentralization of specimen collection and can increase access to VL testing in resource-limited settings. The performance of DBS for VL testing is lower, however, when compared to the gold standard sample type plasma. In this diagnostic accuracy study, we evaluated 3 VL assays with DBS.Participants were recruited between August 2012 and April 2015. Both plasma and DBS specimens were prepared and tested for HIV-1 VL with the Roche CAP/CTM HIV-1 test v2.0, the Abbott RealTime HIV-1, and the bioMérieux NucliSENS EasyQ HIV-1 v2.0. Sensitivity and specificity to detect treatment failure at a threshold of 1000 cps/mL with DBS were determined.A total of 272 HIV-positive patients and 51 HIV-negative people were recruited in the study. The mean difference or bias between plasma and DBS VL was <0.5 log cps/mL with all 3 assays but >25% of the specimens differed by >0.5 log cps/mL.All 3 assays had comparable sensitivities around 80% and specificities around 90%. Upward misclassification rates were around 10%, but downward misclassification rates ranged from 20.3% to 23.6%. Differences in between assays were not statistically significant (P > 0.1).The 3 VL assays evaluated had suboptimal performance with DBS but still performed better than immunological or clinical monitoring. Even after the introduction of the much-anticipated point-of-care VL devices, it is expected that DBS will remain important as a complementary option for supporting access to VL monitoring, particularly in rural, resource-limited settings. Manufacturers should accelerate efforts to develop more reliable, sensitive and specific methods to test VL on DBS specimens.

  7. Optimization and Validation of the TZM-bl Assay for Standardized Assessments of Neutralizing Antibodies Against HIV-1

    PubMed Central

    Sarzotti-Kelsoe, Marcella; Bailer, Robert T; Turk, Ellen; Lin, Chen-li; Bilska, Miroslawa; Greene, Kelli M.; Gao, Hongmei; Todd, Christopher A.; Ozaki, Daniel A.; Seaman, Michael S.; Mascola, John R.; Montefiori, David C.

    2014-01-01

    The TZM-bl assay measures antibody-mediated neutralization of HIV-1 as a function of reductions in HIV-1 Tat-regulated firefly luciferase (Luc) reporter gene expression after a single round of infection with Env-pseudotyped viruses. This assay has become the main endpoint neutralization assay used for the assessment of preclinical and clinical trial samples by a growing number of laboratories worldwide. Here we present the results of the formal optimization and validation of the TZM-bl assay, performed in compliance with Good Clinical Laboratory Practice (GCLP) guidelines. The assay was evaluated for specificity, accuracy, precision, limits of detection and quantitation, linearity, range and robustness. The validated manual TZM-bl assay was also adapted, optimized and qualified to an automated 384-well format. PMID:24291345

  8. Evaluation of the BD Max Cdiff assay for the detection of toxigenic Clostridium difficile in human stool specimens.

    PubMed

    Putsathit, Papanin; Morgan, Justin; Bradford, Damien; Engelhardt, Nelly; Riley, Thomas V

    2015-02-01

    The Becton Dickinson (BD) PCR-based GeneOhm Cdiff assay has demonstrated a high sensitivity and specificity for detecting Clostridium difficile. Recently, the BD Max platform, using the same principles as BD GeneOhm, has become available in Australia. This study aimed to investigate the sensitivity and specificity of BD Max Cdiff assay for the detection of toxigenic C. difficile in an Australian setting. Between December 2013 and January 2014, 406 stool specimens from 349 patients were analysed with the BD Max Cdiff assay. Direct and enrichment toxigenic culture were performed on bioMérieux ChromID C. difficile agar as a reference method. isolates from specimens with discrepant results were further analysed with an in-house PCR to detect the presence of toxin genes. The overall prevalence of toxigenic C. difficile was 7.2%. Concordance between the BD Max assay and enrichment culture was 98.5%. The sensitivity, specificity, positive predictive value and negative predictive value for the BD Max Cdiff assay were 95.5%, 99.0%, 87.5% and 99.7%, respectively, when compared to direct culture, and 91.7%, 99.0%, 88.0% and 99.4%, respectively, when compared to enrichment culture. The new BD Max Cdiff assay appeared to be an excellent platform for rapid and accurate detection of toxigenic C. difficile.

  9. Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis

    PubMed Central

    An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting

    2015-01-01

    The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 “borderline” samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. PMID:25972403

  10. Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis.

    PubMed

    An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2015-07-01

    The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 "borderline" samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  11. Comparative diagnostic evaluation of OMP31 gene based TaqMan® real-time PCR assay with visual LAMP assay and indirect ELISA for caprine brucellosis.

    PubMed

    Saini, Suman; Gupta, V K; Gururaj, K; Singh, D D; Pawaiya, R V S; Gangwar, N K; Mishra, A K; Dwivedi, Deepak; Andani, Dimple; Kumar, Ashok; Goswami, T K

    2017-08-01

    Brucellosis is one of the leading causes of abortion in domestic animals that imposes costs on both economy and society. The disease is highly zoonotic and poses risk to animal handlers due to its zoonotic nature. It causes stillbirth, loss of kids and abortion in last term of pregnancy. Reproductive damage includes infertility in does and orchitis and epididymitis in breeding bucks, which result in high financial losses to farmers and the agriculture industry as a whole. It requires highly sensitive and specific assays to diagnose the disease at field level. In the current study, a visual loop-mediated isothermal amplification (LAMP) assay and the TaqMan® real-time PCR were developed with high sensitivity and specificity. For the TaqMan® probe, real-time PCR primers were developed using Omp31 gene as target and primers were designed using discontiguous conserved sequences of Omp31 gene. The Omp31 probes were designed by attaching 6-FAM reporter dye at the 5' end and BHQ-1 quencher at the 3' end. Published primers were used for visual LAMP assay targeting the Omp25 gene. Sensitivity of the standardized visual LAMP assay and TaqMan® real-time PCR assay was determined by serial dilution of positive Brucella melitensis DNA (10 2 to 10 -4  ng) obtained from standard culture. The TaqMan® probe real-time assay can detect as low as 100 fg of B. melitensis DNA, whereas culture from vaginal swab washings has a limit of detection (LOD) of only 1 cfu/ml. Similarly, the visual LAMP assay can detect as low as 10 fg of B. melitensis DNA as compared to an LOD of 30 cfu/ml from culture of vaginal swab washings. Both assays were compared with serological tests (serum tube agglutination test (STAT) and indirect enzyme-linked immunosorbent assay (iELISA)) for diagnostic sensitivity and specificity. Diagnostic sensitivities and specificities for TaqMan® real-time PCR vs. LAMP assays were 98 and 100% vs. 100 and 97.8%, respectively. Results of visual LAMP assay indicated that LAMP is a fast, specific, sensitive, inexpensive and suitable method for diagnosis of B. melitensis infection under field conditions. On the other hand, Omp31 TaqMan® probe real-time assay can be used in conjunction with the other field-based diagnostic tests due to its high specificity.

  12. Development of real-time and lateral flow dipstick recombinase polymerase amplification assays for rapid detection of goatpox virus and sheeppox virus.

    PubMed

    Yang, Yang; Qin, Xiaodong; Zhang, Xiangle; Zhao, Zhixun; Zhang, Wei; Zhu, Xueliang; Cong, Guozheng; Li, Yanmin; Zhang, Zhidong

    2017-07-17

    Goatpox virus (GTPV) and sheeppox virus (SPPV), which belong to the Capripoxvirus (CaPV), are economically important pathogens of small ruminants. Therefore, a sensitive, specific and rapid diagnostic assay for detection of GTPV and SPPV is necessary to accurately and promptly control these diseases. Recombinase polymerase amplification (RPA) assays combined with a real-time fluorescent detection (real-time RPA assay) and lateral flow dipstick (RPA LFD assay) were developed targeting the CaPV G-protein-coupled chemokine receptor (GPCR) gene, respectively. The sensitivity of both CaPV real-time RPA assay and CaPV RPA LFD assay were 3 × 10 2 copies per reaction within 20 min at 38 °C. Both assays were highly specific for CaPV, with no cross-reactions with peste des petits ruminants virus, foot-and-mouth disease virus and Orf virus. The evaluation of the performance of these two assays with clinical sample (n = 107) showed that the CaPV real-time RPA assay and CaPV RPA LFD assay were able to specially detect SPPV or GTPV present in samples of ovine in liver, lung, kidney, spleen, skin and blood. This study provided a highly time-efficient and simple alternative for rapid detection of GTPV and SPPV.

  13. Performance of the Abbott RealTime CT/NG for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

    PubMed

    Gaydos, C A; Cartwright, C P; Colaninno, P; Welsch, J; Holden, J; Ho, S Y; Webb, E M; Anderson, C; Bertuzis, R; Zhang, L; Miller, T; Leckie, G; Abravaya, K; Robinson, J

    2010-09-01

    A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal swabs. Specimens were tested with the automated Abbott RealTime CT/NG assay, Aptima Combo 2 assay (Gen-Probe), ProbeTec ET CT/GC assay (Becton Dickinson), and culture for N. gonorrhoeae. The Aptima Combo 2 assay, the ProbeTec assay, and the N. gonorrhoeae culture were used as the reference assays. For each subject, a patient infected status (PIS) was determined based on the combined results from the reference assays. The overall prevalence in female subjects was 8.9% for C. trachomatis and 3.8% for N. gonorrhoeae. The overall male prevalence was 18.2% for C. trachomatis and 16.7% for N. gonorrhoeae. The overall sensitivity and specificity of the Abbott RealTime CT/NG assay were 92.4% and 99.2% for C. trachomatis and 96.9% and 99.7% for N. gonorrhoeae, respectively. In comparison, the sensitivity and specificity, respectively, for the Aptima Combo 2 assay were 94.5% and 99.0% for C. trachomatis and 96.1% and 99.5% for N. gonorrhoeae, and those for the ProbeTec ET assay were 90.3% and 99.5% for C. trachomatis and 92.0% and 97.3% for N. gonorrhoeae in this study. The Abbott RealTime CT/NG assay offers C. trachomatis and N. gonorrhoeae dual detection with high sensitivity and specificity. The automated assay provides a useful alternative nucleic acid amplification assay for clinical laboratories and clinicians.

  14. Performance of the Abbott RealTime CT/NG for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae▿

    PubMed Central

    Gaydos, C. A.; Cartwright, C. P.; Colaninno, P.; Welsch, J.; Holden, J.; Ho, S. Y.; Webb, E. M.; Anderson, C.; Bertuzis, R.; Zhang, L.; Miller, T.; Leckie, G.; Abravaya, K.; Robinson, J.

    2010-01-01

    A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal swabs. Specimens were tested with the automated Abbott RealTime CT/NG assay, Aptima Combo 2 assay (Gen-Probe), ProbeTec ET CT/GC assay (Becton Dickinson), and culture for N. gonorrhoeae. The Aptima Combo 2 assay, the ProbeTec assay, and the N. gonorrhoeae culture were used as the reference assays. For each subject, a patient infected status (PIS) was determined based on the combined results from the reference assays. The overall prevalence in female subjects was 8.9% for C. trachomatis and 3.8% for N. gonorrhoeae. The overall male prevalence was 18.2% for C. trachomatis and 16.7% for N. gonorrhoeae. The overall sensitivity and specificity of the Abbott RealTime CT/NG assay were 92.4% and 99.2% for C. trachomatis and 96.9% and 99.7% for N. gonorrhoeae, respectively. In comparison, the sensitivity and specificity, respectively, for the Aptima Combo 2 assay were 94.5% and 99.0% for C. trachomatis and 96.1% and 99.5% for N. gonorrhoeae, and those for the ProbeTec ET assay were 90.3% and 99.5% for C. trachomatis and 92.0% and 97.3% for N. gonorrhoeae in this study. The Abbott RealTime CT/NG assay offers C. trachomatis and N. gonorrhoeae dual detection with high sensitivity and specificity. The automated assay provides a useful alternative nucleic acid amplification assay for clinical laboratories and clinicians. PMID:20668135

  15. Development and validation of a Luminex assay for detection of a predictive biomarker for PROSTVAC-VF therapy

    PubMed Central

    Lucas, Julie L.; Tacheny, Erin A.; Ferris, Allison; Galusha, Michelle; Srivastava, Apurva K.; Ganguly, Aniruddha; Williams, P. Mickey; Sachs, Michael C.; Thurin, Magdalena; Tricoli, James V.; Ricker, Winnie; Gildersleeve, Jeffrey C.

    2017-01-01

    Cancer therapies can provide substantially improved survival in some patients while other seemingly similar patients receive little or no benefit. Strategies to identify patients likely to respond well to a given therapy could significantly improve health care outcomes by maximizing clinical benefits while reducing toxicities and adverse effects. Using a glycan microarray assay, we recently reported that pretreatment serum levels of IgM specific to blood group A trisaccharide (BG-Atri) correlate positively with overall survival of cancer patients on PROSTVAC-VF therapy. The results suggested anti-BG-Atri IgM measured prior to treatment could serve as a biomarker for identifying patients likely to benefit from PROSTVAC-VF. For continued development and clinical application of serum IgM specific to BG-Atri as a predictive biomarker, a clinical assay was needed. In this study, we developed and validated a Luminex-based clinical assay for measuring serum IgM specific to BG-Atri. IgM levels were measured with the Luminex assay and compared to levels measured using the microarray for 126 healthy individuals and 77 prostate cancer patients. This assay provided reproducible and consistent results with low %CVs, and tolerance ranges were established for the assay. IgM levels measured using the Luminex assay were found to be highly correlated to the microarray results with R values of 0.93–0.95. This assay is a Laboratory Developed Test (LDT) and is suitable for evaluating thousands of serum samples in CLIA certified laboratories that have validated the assay. In addition, the study demonstrates that discoveries made using neoglycoprotein-based microarrays can be readily migrated to a clinical assay. PMID:28771597

  16. HCV core-antigen assay as an alternative to HCV RNA quantification: A correlation study for the assessment of HCV viremia.

    PubMed

    Alonso, Roberto; Pérez-García, Felipe; López-Roa, Paula; Alcalá, Luis; Rodeño, Pilar; Bouza, Emilio

    2018-03-01

    Detection of hepatitis C virus (HCV) RNA and the HCV core antigen assay (HCV-Ag) are reliable techniques for the diagnosis of active and chronic HCV infection. Our aim was to evaluate the HCV-Ag assay as an alternative to quantification of HVC RNA. A comparison was made of the sensitivity and specificity of an HCV-Ag assay (204 serum samples) with those of a PCR assay, and the correlation between the two techniques was determined. The sensitivity and specificity of HCV-Ag was 76.6% and 100%, respectively. Both assays were extremely well correlated (Pearson coefficient=0.951). The formula (LogCV=1.15*LogAg+2.26) was obtained to calculate the viral load by PCR from HCV-Ag values. HCV-Ag was unable to detect viral loads below 5000IU/mL. Although the HCV-Ag assay was less sensitive than the PCR assay, the correlation between both assays was excellent. HCV-Ag can be useful as a first step in the diagnosis of acute or chronic HCV infection and in emergency situations. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  17. Development and Clinical Evaluation of a Recombinant-Antigen-Based Cytomegalovirus Immunoglobulin M Automated Immunoassay Using the Abbott AxSYM Analyzer

    PubMed Central

    Maine, G. T.; Stricker, R.; Schuler, M.; Spesard, J.; Brojanac, S.; Iriarte, B.; Herwig, K.; Gramins, T.; Combs, B.; Wise, J.; Simmons, H.; Gram, T.; Lonze, J.; Ruzicki, D.; Byrne, B.; Clifton, J. D.; Chovan, L. E.; Wachta, D.; Holas, C.; Wang, D.; Wilson, T.; Tomazic-Allen, S.; Clements, M. A.; Wright, G. L.; Lazzarotto, T.; Ripalti, A.; Landini, M. P.

    2000-01-01

    A new microparticle enzyme immunoassay (MEIA), the Cytomegalovirus (CMV) Immunoglobulin M (IgM) test, was developed on the Abbott AxSYM analyzer. This test uses recombinant CMV antigens derived from portions of four structural and nonstructural proteins of CMV: pUL32 (pp150), pUL44 (pp52), pUL83 (pp65), and pUL80a (pp38). A total of 1,608 specimens from random volunteer blood donors (n = 300), pregnant women (n = 1,118), transplant recipients (n = 6), and patients with various clinical conditions and disease states (n = 184) were tested during development and evaluation of this new assay. In a preliminary clinical evaluation we tested specimens collected prospectively from pregnant women (n = 799) and selected CMV IgM-positive archived specimens from pregnant women (n = 39). The results from the new CMV IgM immunoassay were compared to the results of a consensus interpretation of the results obtained with three commercial CMV IgM immunoassays. The results for specimens with discordant results were resolved by a CMV IgM immunoblot assay. The relative sensitivity, specificity, and agreement for the AxSYM CMV IgM assay were 94.29, 96.28, and 96.19%, respectively, and the resolved sensitivity, specificity, and agreement were 95.83, 97.47, and 97.37%, respectively. We also tested serial specimens from women who experienced seroconversion or a recent CMV infection during gestation (n = 17) and potentially cross-reactive specimens negative for CMV IgM antibody by the consensus tests (n = 184). The AxSYM CMV IgM assay was very sensitive for the detection of CMV IgM during primary CMV infection, as shown by the detection of CMV IgM at the same time as or just prior to the detection of CMV IgG. Specimens from individuals with lupus (n = 16) or parvovirus B19 infection (n = 6) or specimens containing hyper IgM (n = 9), hyper IgG (n = 8), or rheumatoid factor (n = 55) did not cross-react with the AxSYM assay. One specimen each from individuals infected with Epstein-Barr virus (n = 26), measles virus (n = 10), herpes simplex virus (n = 12), or varicella-zoster virus (n = 13) infection, one specimen from an influenza vaccinee (n = 14), and one specimen containing antinuclear antibody cross-reacted with the assay. The overall rate of cross-reactivity of the specimens with the assay was 3.3% (6 of 184). The AxSYM CMV IgM assay is a sensitive and specific assay for the detection of CMV-specific IgM. PMID:10747129

  18. Analytical characterization and clinical evaluation of an enzyme-linked immunosorbent assay for measurement of afamin in human plasma.

    PubMed

    Dieplinger, Benjamin; Egger, Margot; Gabriel, Christian; Poelz, Werner; Morandell, Elisabeth; Seeber, Beata; Kronenberg, Florian; Haltmayer, Meinhard; Mueller, Thomas; Dieplinger, Hans

    2013-10-21

    Comparative proteomics has recently identified afamin, the newest member of the albumin gene family, as a potential biomarker for ovarian cancer. The aim of this study was the analytical and clinical evaluation of a sandwich enzyme-linked immunosorbent assay for the determination of afamin in human plasma. We evaluated precision, linearity, and detection limit of the assay, analyte stability and biological variability, determined reference values and quantified afamin concentrations in various diseases. Within-run and total coefficients of variation were <10%. The method was linear across the tested measurement range. Detection limit was 7 mg/L for the assay. The analyte was stable for 24 h at room temperature, for 48 h at 4°C, and for at least one year at -20°C and -80°C. The reference change value for healthy individuals was 24%. Age- and sex-independent reference values in healthy blood donors were 45-99 mg/L (median 68 mg/L). In the clinical assay evaluation afamin plasma concentrations were modestly decreased in patients with heart failure. Patients with pneumonia or sepsis exhibited markedly decreased afamin plasma concentrations. However, patients with chronic renal disease or chronic obstructive pulmonary disease showed no difference in afamin plasma concentrations as compared to healthy individuals. Correlation analyses revealed an inverse association between afamin and inflammatory biomarkers. The afamin assay meets quality specifications for laboratory medicine. The results of the clinical assay evaluation revealed novel insights with respect to afamin as a potential negative acute phase protein and should encourage further studies. © 2013.

  19. Contribution of murine innate serum inhibitors toward interference within influenza virus immune assays

    PubMed Central

    Cwach, Kevin T.; Sandbulte, Heather R.; Klonoski, Joshua M.; Huber, Victor C.

    2011-01-01

    Please cite this paper as: Cwach et al. (2011) Contribution of murine innate serum inhibitors toward interference within influenza virus immune assays. Influenza and Other Respiratory Viruses DOI: 10.1111/j.1750‐2659.2011.00283.x. Background  Prior to detection of an antibody response toward influenza viruses using the hemagglutination inhibition assay (HAI), sera are routinely treated to inactivate innate inhibitors using both heat inactivation (56°C) and recombinant neuraminidase [receptor‐destroying enzyme (RDE)]. Objectives  We revisited the contributions of innate serum inhibitors toward interference with influenza viruses in immune assays, using murine sera, with emphasis on the interactions with influenza A viruses of the H3N2 subtype. Methods  We used individual serum treatments: 56°C alone, RDE alone, or RDE + 56°C, to treat sera prior to evaluation within HAI, microneutralization, and macrophage uptake assays. Results  Our data demonstrate that inhibitors present within untreated murine sera interfere with the HAI assay in a manner that is different from that seen for the microneutralization assay. Specifically, the γ class inhibitor α2‐Macroglobulin (A2‐M) can inhibit H3N2 viruses within the HAI assay, but not in the microneutralization assay. Based on these findings, we used a macrophage uptake assay to demonstrate that these inhibitors can increase uptake by macrophages when the influenza viruses express an HA from a 1968 H3N2 virus isolate, but not a 1997 H3N2 isolate. Conclusions  The practice of treating sera to inactivate innate inhibitors of influenza viruses prior to evaluation within immune assays has allowed us to effectively detect influenza virus‐specific antibodies for decades. However, this practice has yielded an under‐appreciation for the contribution of innate serum inhibitors toward host immune responses against these viruses, including contributions toward neutralization and macrophage uptake. PMID:21883963

  20. Duplex Quantitative PCR Assay for Detection of Haemophilus influenzae That Distinguishes Fucose- and Protein D-Negative Strains

    PubMed Central

    de Gier, Camilla; Pickering, Janessa L.; Richmond, Peter C.; Thornton, Ruth B.

    2016-01-01

    We have developed a specific Haemophilus influenzae quantitative PCR (qPCR) that also identifies fucose-negative and protein D-negative strains. Analysis of 100 H. influenzae isolates, 28 Haemophilus haemolyticus isolates, and 14 other bacterial species revealed 100% sensitivity (95% confidence interval [CI], 96% to 100%) and 100% specificity (95% CI, 92% to 100%) for this assay. The evaluation of 80 clinical specimens demonstrated a strong correlation between semiquantitative culture and the qPCR (P < 0.001). PMID:27335148

  1. Usefulness of Multiplex Real-Time PCR for Simultaneous Pathogen Detection and Resistance Profiling of Staphylococcal Bacteremia

    PubMed Central

    Chung, Yousun; Kim, Taek Soo; Min, Young Gi; Hong, Yun Ji; Park, Jeong Su; Hwang, Sang Mee; Song, Kyoung-Ho; Kim, Eu Suk; Kim, Hong Bin; Song, Junghan; Kim, Eui-Chong

    2016-01-01

    Staphylococci are the leading cause of nosocomial blood stream infections. Fast and accurate identification of staphylococci and confirmation of their methicillin resistance are crucial for immediate treatment with effective antibiotics. A multiplex real-time PCR assay that targets mecA, femA specific for S. aureus, femA specific for S. epidermidis, 16S rRNA for universal bacteria, and 16S rRNA specific for staphylococci was developed and evaluated with 290 clinical blood culture samples containing Gram-positive cocci in clusters (GPCC). For the 262 blood cultures identified to the species level with the MicroScan WalkAway system (Siemens Healthcare Diagnostics, USA), the direct real-time PCR assay of positive blood cultures showed very good agreement for the categorization of staphylococci into methicillin-resistant S. aureus (MRSA), methicillin-susceptible S. aureus (MSSA), methicillin-resistant S. epidermidis (MRSE), methicillin-susceptible S. epidermidis (MSSE), methicillin-resistant non-S. epidermidis CoNS (MRCoNS), and methicillin-susceptible non-S. epidermidis CoNS (MSCoNS) (κ = 0.9313). The direct multiplex real-time PCR assay of positive blood cultures containing GPCC can provide essential information at the critical point of infection with a turnaround time of no more than 4 h. Further studies should evaluate the clinical outcome of using this rapid real-time PCR assay in glycopeptide antibiotic therapy in clinical settings. PMID:27403436

  2. Ma2 antibodies: an evaluation of commercially available detection methods.

    PubMed

    Johannis, Wibke; Renno, Joerg H; Wielckens, Klaus; Voltz, Raymond

    2011-01-01

    Ma2 antibodies belong to the onconeuronal antibodies which define a "definite" paraneoplastic neurological syndrome (PNS). Because of the clinical relevance, use of two separate methods (indirect immunofluorescence technique--IFT--and immunoblot) is advocated; however, with an increasing number of commercially available assay systems, usually only one assay is performed. We compared IFT and three commercially available immunoblots (ravo Diagnostika, Euroimmun, Milenia Biotec) on sera from 35 patients with clinically suspected PNS. 17 were Ma2 antibody associated as defined by consensus result (showing positive reactivity in 2 assays), 18 were Ma2 antibody negative controls. Sensitivity/specificity for single assays were for IFT 94%/94%, for ravo Diagnostika PNS blot 88%/100%, for Euroimmun Neuronal Antigens Profile blot 100%/89%, and for Milenia Biotec MTR blot 94%/100%. Our data confirm, although all tests performed well, a combination of 2 independent assays is still advisable for Ma2 antibody detection in order to achieve higher sensitivity and specificity rates.

  3. Development of a multiplex allele-specific primer PCR assay for simultaneous detection of QoI and CAA fungicide resistance alleles in Plasmopara viticola populations.

    PubMed

    Aoki, Yoshinao; Hada, Yosuke; Suzuki, Shunji

    2013-02-01

    DNA-based diagnosis has become a common tool for the evaluation of fungicide resistance in obligate phytopathogenic fungus Plasmopara viticola. A multiplex allele-specific primer PCR assay has been developed for the rapid detection of fungicide resistance in P. viticola populations. With this assay, a glycine-to-alanine substitution at codon 143 of the P. viticola cytochrome b gene, which conferred QoI fungicide resistance, and a glycine-to-serine substitution at codon 1105 of the P. viticola cellulose synthase gene PvCesA3, which conferred CAA fungicide resistance, were detected simultaneously. It is suggested that the present assay is a reliable tool for the rapid and simultaneous detection of QoI and CAA fungicide resistance alleles in P. viticola populations. The assay required only 2 h from the sampling of symptoms to the detection of resistance alleles to both fungicides. Copyright © 2012 Society of Chemical Industry.

  4. The Lumipulse G HBsAg-Quant assay for screening and quantification of the hepatitis B surface antigen.

    PubMed

    Yang, Ruifeng; Song, Guangjun; Guan, Wenli; Wang, Qian; Liu, Yan; Wei, Lai

    2016-02-01

    Qualitative HBsAg assay is used to screen HBV infection for decades. The utility of quantitative assay is also rejuvenated recently. We aimed to evaluate and compare the performance of a novel ultra-sensitive and quantitative assay, the Lumipulse assay, with the Architect and Elecsys assays. As screening methods, specificity was compared using 2043 consecutive clinical routine samples. As quantitative assays, precision and accuracy were assessed. Sera from 112 treatment-naïve chronic hepatitis B patients, four patients undergoing antiviral therapy and one patient with acute infection were tested to compare the correlations. Samples with concurrent HBsAg/anti-HBs were also quantified. The Lumipulse assay precisely quantified ultra-low level of HBsAg (0.004 IU/mL). It identified additional 0.98% (20/2043) clinical samples with trance amount of HBsAg. Three assays displayed excellent linear correlations irrespective of genotypes and S-gene mutations (R(2)>0.95, P<0.0001), while minor quantitative biases existed. The Lumipulse assay did not yield higher HBsAg concentrations in samples with concomitant anti-HBs. Compared with other assays, the Lumipulse assay is sensitive and specific for detecting HBsAg. The interpretation of the extremely low-level results, however, is challenging. Quantitative HBsAg results by different assays are highly correlated, but they should be interpreted interchangeably only after conversion to eliminate the biases. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. An integrated target sequence and signal amplification assay, reverse transcriptase-PCR-enzyme-linked immunosorbent assay, to detect and characterize flaviviruses.

    PubMed Central

    Chang, G J; Trent, D W; Vorndam, A V; Vergne, E; Kinney, R M; Mitchell, C J

    1994-01-01

    We previously described a reverse transcriptase-PCR using flavivirus genus-conserved and virus species-specific amplimers (D. W. Trent and G. J. Chang, p. 355-371, in Y. Becker and C. Darai; ed., Frontiers of Virology, vol. 1, 1992). Target amplification was improved by redesigning the amplimers, and a sensitive enzyme-linked immunosorbent assay (ELISA) technique has been developed to detect amplified digoxigenin (DIG)-modified DNA. A single biotin motif and multiple DIG motifs were incorporated into each amplicon, which permitted amplicon capture by a biotin-streptavidin interaction and detection with DIG-specific antiserum in a colorimetric ELISA. We evaluated the utility of this assay for detecting St. Louis encephalitis (SLE) viral RNA in infected mosquitoes and dengue viral RNA in human serum specimens. The reverse transcriptase-PCR-ELISA was as sensitive as isolation of SLE virus by cell culture in detecting SLE viral RNA in infected mosquitoes. The test was 89% specific and 95 to 100% sensitive for identification of dengue viral RNA in serum specimens compared with isolation of virus by Aedes albopictus C6/36 cell culture and identification by the indirect immunofluorescence assay. PMID:7512096

  6. An integrated target sequence and signal amplification assay, reverse transcriptase-PCR-enzyme-linked immunosorbent assay, to detect and characterize flaviviruses.

    PubMed

    Chang, G J; Trent, D W; Vorndam, A V; Vergne, E; Kinney, R M; Mitchell, C J

    1994-02-01

    We previously described a reverse transcriptase-PCR using flavivirus genus-conserved and virus species-specific amplimers (D. W. Trent and G. J. Chang, p. 355-371, in Y. Becker and C. Darai; ed., Frontiers of Virology, vol. 1, 1992). Target amplification was improved by redesigning the amplimers, and a sensitive enzyme-linked immunosorbent assay (ELISA) technique has been developed to detect amplified digoxigenin (DIG)-modified DNA. A single biotin motif and multiple DIG motifs were incorporated into each amplicon, which permitted amplicon capture by a biotin-streptavidin interaction and detection with DIG-specific antiserum in a colorimetric ELISA. We evaluated the utility of this assay for detecting St. Louis encephalitis (SLE) viral RNA in infected mosquitoes and dengue viral RNA in human serum specimens. The reverse transcriptase-PCR-ELISA was as sensitive as isolation of SLE virus by cell culture in detecting SLE viral RNA in infected mosquitoes. The test was 89% specific and 95 to 100% sensitive for identification of dengue viral RNA in serum specimens compared with isolation of virus by Aedes albopictus C6/36 cell culture and identification by the indirect immunofluorescence assay.

  7. Role of sampling times and serum cortisol cut-off concentrations on the routine assessment of adrenal function using the standard cosyntropin test in an academic hospital from Spain: a retrospective chart review.

    PubMed

    Ortiz-Flores, Andrés E; Santacruz, Elisa; Jiménez-Mendiguchia, Lucía; García-Cano, Ana; Nattero-Chávez, Lia; Escobar-Morreale, Héctor F; Luque-Ramírez, Manuel

    2018-05-05

    Aiming to validate the use of a single poststimulus sampling protocol for cosyntropin test short standard high-dose test (SST) in our institution, our primary objectives were (1) to determine the concordance between 30 and 60 min serum cortisol (SC) measurements during SST; and (2) to evaluate the diagnostic agreement between both sampling times when using classic or assay-specific and sex-specific SC cut-off values. The secondary objectives included (1) estimating the specificity and positive predictive value of 30 and 60 min sampling times while considering the suspected origin of adrenal insufficiency (AI); and (2) obtaining assay-specific cut-off values for SC after SST in a group of subjects with normal hypothalamic-pituitary-adrenal (HPA) axis. This is a retrospective chart review study conducted at a Spanish academic hospital from 2011 to 2015. Two groups were evaluated: (1) a main study group including 370 patients in whom SC was measured at 30 and 60 min during SST; and (2) a confirmative group that included 150 women presenting with a normal HPA axis in whom SST was conducted to rule out late-onset congenital adrenal hyperplasia. Diagnostic agreement between both sampling times was assessed by considering both classic (500 nmol/L) and assay-specific SC cut-off concentrations. Diagnostic agreement between both sampling times was greater when applying sex-specific and assay-specific cut-off values instead of the classic cut-off values. For suspected primary AI, 30 min SC determination was enough to establish a diagnosis in over 95% of cases, without missing any necessary treatment. When central AI is suspected, 60 min SC measurement was more specific, establishing a diagnosis in over 97% of cases. Sex-specific and assay-specific SC cut-off values improve the diagnostic accuracy of SST. For primary disease, a subnormal SC response at 30 min is a reliable marker of adrenal dysfunction. On the contrary, when central AI is suspected, 60 min SC measurement improves the diagnostic accuracy of the test. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Development of an opsonophagocytic killing assay for group a streptococcus.

    PubMed

    Jones, Scott; Moreland, Nicole J; Zancolli, Marta; Raynes, Jeremy; Loh, Jacelyn M S; Smeesters, Pierre R; Sriskandan, Shiranee; Carapetis, Jonathan R; Fraser, John D; Goldblatt, David

    2018-05-15

    Group A Streptococcus (GAS) or Streptococcus pyogenes is responsible for an estimated 500,000 deaths worldwide each year. Protection against GAS infection is thought to be mediated by phagocytosis, enhanced by bacteria-specific antibody. There are no licenced GAS vaccines, despite many promising candidates in preclinical and early stage clinical development, the most advanced of which are based on the GAS M-protein. Vaccine progress has been hindered, in part, by the lack of a standardised functional assay suitable for vaccine evaluation. Current assays, developed over 50 years ago, rely on non-immune human whole blood as a source of neutrophils and complement. Variations in complement and neutrophil activity between donors result in variable data that is difficult to interpret. We have developed an opsonophagocytic killing assay (OPKA) for GAS that utilises dimethylformamide (DMF)-differentiated human promyelocytic leukemia cells (HL-60) as a source of neutrophils and baby rabbit complement, thus removing the major sources of variation in current assays. We have standardised the OPKA for several clinically relevant GAS strain types (emm1, emm6 and emm12) and have shown antibody-specific killing for each emm-type using M-protein specific rabbit antisera. Specificity was demonstrated by pre-incubation of the antisera with homologous M-protein antigens that blocked antibody-specific killing. Additional qualifications of the GAS OPKA, including the assessment of the accuracy, precision, linearity and the lower limit of quantification, were also performed. This GAS OPKA assay has the potential to provide a robust and reproducible platform to accelerate GAS vaccine development. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. A novel strategy for rapid detection of NT-proBNP

    NASA Astrophysics Data System (ADS)

    Cui, Qiyao; Sun, Honghao; Zhu, Hui

    2017-09-01

    In order to establish a simple, rapid, sensitive, and specific quantitative assay to detect the biomarkers of heart failure, in this study, biotin-streptavidin technology was employed with fluorescence immunochromatographic assay to detect the concentration of the biomarkers in serum, and this method was applied to detect NT-proBNP, which is valuable for diagnostic evaluation of heart failure.

  10. Detecting West Nile virus in owls and raptors by an antigen-capture assay.

    PubMed

    Gancz, Ady Y; Campbell, Douglas G; Barker, Ian K; Lindsay, Robbin; Hunter, Bruce

    2004-12-01

    We evaluated a rapid antigen-capture assay (VecTest) for detection of West Nile virus in oropharyngeal and cloacal swabs, collected at necropsy from owls (N = 93) and raptors (N = 27). Sensitivity was 93.5%-95.2% for northern owl species but <42.9% for all other species. Specificity was 100% for owls and 85.7% for raptors.

  11. Evaluation of puberty by verifying spontaneous and stimulated gonadotropin values in girls.

    PubMed

    Chin, Vivian L; Cai, Ziyong; Lam, Leslie; Shah, Bina; Zhou, Ping

    2015-03-01

    Changes in pharmacological agents and advancements in laboratory assays have changed the gonadotropin-releasing hormone analog stimulation test. To determine the best predictive model for detecting puberty in girls. Thirty-five girls, aged 2 years 7 months to 9 years 3 months, with central precocious puberty (CPP) (n=20) or premature thelarche/premature adrenarche (n=15). Diagnoses were based on clinical information, baseline hormones, bone age, and pelvic sonogram. Gonadotropins and E2 were analyzed using immunochemiluminometric assay. Logistic regression for CPP was performed. The best predictor of CPP is the E2-change model based on 3- to 24-h values, providing 80% sensitivity and 87% specificity. Three-hour luteinizing hormone (LH) provided 75% sensitivity and 87% specificity. Basal LH lowered sensitivity to 65% and specificity to 53%. The E2-change model provided the best predictive power; however, 3-h LH was more practical and convenient when evaluating puberty in girls.

  12. Development and evaluation of internal amplification controls for use in a real-time duplex PCR assay for detection of Campylobacter coli and Campylobacter jejuni.

    PubMed

    Randall, Luke; Lemma, Fabrizio; Rodgers, John; Vidal, Ana; Clifton-Hadley, Felicity

    2010-02-01

    A common problem of both conventional and real-time PCR assays is failure of DNA amplification due to the presence of inhibitory substances in samples. In view of this, our aim was to develop and evaluate internal amplification controls (IACs) for use with an existing duplex real-time PCR assay for Campylobacter coli and Campylobacter jejuni. Both competitive and non-competitive IACs were developed and evaluated. The competitive approach involved a DNA fragment of the coding region of the fish viral haemorrhagic septicaemia virus, flanked by the mapA PCR primers, whilst the non-competitive approach utilized an extra set of universal 16S rDNA primers. Both IAC-PCR assay types were evaluated using cultures of Campylobacter and chicken caecal content samples. Both IACs were sensitive to caecal inhibitors, making them suitable for detecting inhibition which could lead to false-negatives. Results showed that both IACs at optimum concentrations worked well without reducing the overall sensitivity of the PCR assay. Compared to culture, the optimized competitive IAC-PCR assay detected 45/47 positives (sensitivity 93.6 %, specificity 80.1 %); however, it had the advantage over culture in that it could detect mixed infections of C. coli and C. jejuni and was capable of giving a result for a sample within a day.

  13. Prospective evaluation of the Alere i Influenza A&B nucleic acid amplification versus Xpert Flu/RSV.

    PubMed

    Nguyen Van, J C; Caméléna, F; Dahoun, M; Pilmis, B; Mizrahi, A; Lourtet, J; Behillil, S; Enouf, V; Le Monnier, A

    2016-05-01

    The rapid and accurate detection of influenza virus in respiratory specimens is required for optimal management of patients with acute respiratory infections. Because of the variability of the symptoms and the numerous other causes of influenza-like illness, the diagnosis of influenza cannot be made on the basis of clinical criteria alone. Thus, rapid influenza diagnostic tests have been developed such as the Alere i Influenza A&B isothermal nucleic acid assay. We prospectively evaluated the performance of the Alere i Influenza A&B assay in comparison with our routine Xpert Flu/RSV assay. Positive samples were subtyped according to the protocol from the National Influenza Center (Paris, France). A total of 96 respiratory nasal swab samples were analyzed: with both methods, 38 were positive and 56 were negative. Samples were prospectively collected from January 20 to April 8, 2015, from patient (86 adult and 10 pediatric patients) presenting with an influenza-like illness through the French influenza season. In comparison with the Xpert Flu/RSV assay, the overall sensitivity and specificity of the Alere i Influenza A&B assay were 95% and 100%, respectively. Our results indicate that the Alere i Influenza A&B assay has a good overall analytical performance and a high degree of concordance with the PCR-based Xpert Flu/RSV assay. The Alere i Influenza A&B isothermal nucleic acid amplification test is a powerful tool for influenza detection due to its high sensitivity and specificity as well as its ability to generate results within 15min. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. A novel DNA/histone H4 peptide complex detects autoantibodies in systemic lupus erythematosus sera.

    PubMed

    Panza, Filomena; Alcaro, Maria Claudia; Petrelli, Fiorella; Angelotti, Francesca; Pratesi, Federico; Rovero, Paolo; Migliorini, Paola

    2016-10-04

    The detection of anti-dsDNA antibodies is critical for the diagnosis and follow-up of systemic lupus erythematosus (SLE) patients. The presently available assays are characterized by a non-optimal specificity (solid phase assays) or sensitivity (Crithidia Luciliae immunofluorescence test (CLIFT)). To overcome the limits of CLIFT and solid phase chromatin assays, we explored the diagnostic potential of an assay based on plasmid DNA containing a highly bent fragment of 211 bp from Crithidia Luciliae minicircles, complexed with histone peptides. Electrically neutral complexes of PK201/CAT plasmid (PK) DNA and histone 4 (H4) peptides were evaluated by electromobility shift assay. Complexes of H4 peptides and PK were absorbed to the solid phase to detect specific immunoglobulin G (IgG) in sera. Sera from 109 SLE patients, 100 normal healthy subjects, and 169 disease controls were tested. H4(14-34) containing the consensus sequence for DNA binding interacts with PK, retarding its migration. H4(14-34)/PK complexes were used to test sera by ELISA. Anti-H4-PK antibodies were detected in 56 % of SLE sera (more frequently in patients with skin or joint involvement) versus 5.9 % in disease controls; inhibition assays show that sera react with epitopes present on DNA or on the complex, not on the peptide. Antibody titer is correlated with European Consensus Lupus Activity Measurement (ECLAM) score and anti-complement component 1q (C1q) antibodies, negatively with C3 levels. Anti-H4-PK antibodies compared with CLIFT and solid phase dsDNA assays display moderate concordance. The H4/PK assay is a simple and reliable test which is useful for the differential diagnosis and evaluation of disease activity in SLE patients.

  15. Multiplex PCR assay to identify methicillin-resistant Staphylococcus haemolyticus.

    PubMed

    Schuenck, Ricardo P; Pereira, Eliezer M; Iorio, Natalia L P; Dos Santos, Kátia R N

    2008-04-01

    Staphylococcus haemolyticus is the most frequently coagulase-negative Staphylococcus species associated with antimicrobial resistance isolated from nosocomial infections. We developed an accurate and simple multiplex PCR assay to identify methicillin-resistant S. haemolyticus (MRSH) isolates. We designed species-specific primers of the mvaA gene that encodes a 3-hydroxy-3-methylglutaryl coenzyme A involved in the mevalonate pathway of the microorganism. Simultaneously, mecA gene primers of methicillin resistance were also used. The PCR assay was established using 16 strains of different reference Staphylococcus species and validated with a collection of 147 clinical staphylococcal isolates that were also phenotypically characterized. Reliable results for the detection of MRSH isolates were obtained for 100% of the strains evaluated, showing that this PCR assay can be used for the routine microbiology laboratories. This is the first report using species-specific multiplex PCR to detect a single segment of S. haemolyticus associated with a segment of mecA gene.

  16. Comparative Evaluation of Serological and Molecular Methods for the Diagnosis of Scrub Typhus in Indian Settings.

    PubMed

    Gupta, Nitin; Chaudhry, Rama; Kabra, Sushil K; Lodha, Rakesh; Mirdha, Bijay Ranjan; Das, Bimal Kumar; Dey, Aparajit Ballay; Sreenivas, Vishnubhatla

    2017-03-24

    The major brunt of scrub typhus is borne by developing countries like India but the disease remains neglected. The rapid progression of this infection to serious complications and associated mortality calls for improved diagnostics. The immunoglobulin (Ig)M immunofluorescence assay (IFA), with all of its limitations remains the gold standard. Of 218 suspected cases from patients enrolled in a 2-year study, 30 cases of scrub typhus were detected by IgM IFA, using a 1:64 dilution. The sensitivities of the IgM enzyme-linked immunosorbent assay, IgM rapid flow assay (RFA), and IgG RFA were found to be 97%, 87%, and 77%, respectively. Their respective specificities were 100%, 100%, and 92%, respectively. The sensitivity and specificity of a nested PCR assay targeting a gene encoding a 56-kDa protein were found to be 50% and 100%, respectively.

  17. Cross reactions elicited by serum 17-OH progesterone and 11-desoxycortisol in cortisol assays.

    PubMed

    Brossaud, Julie; Barat, Pascal; Gualde, Dominique; Corcuff, Jean-Benoît

    2009-09-01

    Different pathophysiological situations such as congenital adrenal hyperplasia, adrenocortical carcinoma, metyrapone treatment, etc. elicit specificity problems with serum cortisol assay. We assayed cortisol using 2 kits and performed cross reaction studies as well as multiple regression analysis using 2 other steroids: 11-desoxycortisol and 17-OH progesterone. Analysis showed the existence of an analytical bias. Importantly, significantly different biases were demonstrated in newborns or patients taking metyrapone. Multiple regression analysis and cross reaction studies showed that 11-desoxycortisol level significantly influenced cortisol determination. Moreover, despite using the normal ranges provided by manufacturers discrepant results occurred such as 17% discordance in the diagnosis of hypocorticism in infants. We wish to raise awareness about the consequences of the (lack of) specificity of cortisol assays with regard to the evaluation of hypocorticism in infants or when "unusual" steroids may be increased.

  18. Evaluation of a new T2 Magnetic Resonance assay for rapid detection of emergent fungal pathogen Candida auris on clinical skin swab samples.

    PubMed

    Sexton, D Joseph; Bentz, Meghan L; Welsh, Rory M; Litvintseva, Anastasia P

    2018-06-25

    Candida auris is a multidrug-resistant pathogenic yeast whose recent emergence is of increasing public-health concern. C. auris can colonize multiple body sites, including patients' skin, and survive for weeks in the healthcare environment, facilitating patient-to-patient transmission and fueling healthcare-associated outbreaks. Rapid and accurate detection of C. auris colonization is essential for timely implementation of infection control measures and prevent transmission. Currently, axilla/groin composite swabs, used to assess colonization status, are processed using a culture-based method that is sensitive and specific but requires 14 days. This delay limits the opportunity to respond and highlights the need for a faster alternative. The culture-independent T2 Magnetic Resonance (T2MR) system is a rapid diagnostic platform shown to detect target pathogens of interest from unprocessed blood samples in <5 hours. In this study, a new C. auris-specific T2 assay was evaluated for screening of the skin surveillance samples. Inclusivity and limit of detection of the T2 C. auris assay were assessed with spiked samples in a representative skin flora background. The T2 C. auris assay recognized isolates from each of the 4 known clades of C. auris and consistently detected cells at 5 CFU/mL. Finally, 89 clinical axilla/groin swab samples were processed with the T2 C. auris assay. The culture-based diagnostic assay was used as a gold standard to determine performance statistics including sensitivity (0.89) and specificity (0.98). Overall, the T2 C. auris assay performed well as a rapid diagnostic and could help expedite the detection of C. auris in patient skin swabs. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Critical issues with the in vivo comet assay: A report of the comet assay working group in the 6th International Workshop on Genotoxicity Testing (IWGT).

    PubMed

    Speit, Günter; Kojima, Hajime; Burlinson, Brian; Collins, Andrew R; Kasper, Peter; Plappert-Helbig, Ulla; Uno, Yoshifumi; Vasquez, Marie; Beevers, Carol; De Boeck, Marlies; Escobar, Patricia A; Kitamoto, Sachiko; Pant, Kamala; Pfuhler, Stefan; Tanaka, Jin; Levy, Dan D

    2015-05-01

    As a part of the 6th IWGT, an expert working group on the comet assay evaluated critical topics related to the use of the in vivo comet assay in regulatory genotoxicity testing. The areas covered were: identification of the domain of applicability and regulatory acceptance, identification of critical parameters of the protocol and attempts to standardize the assay, experience with combination and integration with other in vivo studies, demonstration of laboratory proficiency, sensitivity and power of the protocol used, use of different tissues, freezing of samples, and choice of appropriate measures of cytotoxicity. The standard protocol detects various types of DNA lesions but it does not detect all types of DNA damage. Modifications of the standard protocol may be used to detect additional types of specific DNA damage (e.g., cross-links, bulky adducts, oxidized bases). In addition, the working group identified critical parameters that should be carefully controlled and described in detail in every published study protocol. In vivo comet assay results are more reliable if they were obtained in laboratories that have demonstrated proficiency. This includes demonstration of adequate response to vehicle controls and an adequate response to a positive control for each tissue being examined. There was a general agreement that freezing of samples is an option but more data are needed in order to establish generally accepted protocols. With regard to tissue toxicity, the working group concluded that cytotoxicity could be a confounder of comet results. It is recommended to look at multiple parameters such as histopathological observations, organ-specific clinical chemistry as well as indicators of tissue inflammation to decide whether compound-specific toxicity might influence the result. The expert working group concluded that the alkaline in vivo comet assay is a mature test for the evaluation of genotoxicity and can be recommended to regulatory agencies for use. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Evaluation of Seegene Allplex Respiratory Panel 1 kit for the detection of influenza virus and human respiratory syncytial virus.

    PubMed

    Gimferrer, Laura; Andrés, Cristina; Rando, Ariadna; Piñana, Maria; Codina, Maria Gema; Martin, Maria Del Carmen; Fuentes, Francisco; Rubio, Susana; Alcubilla, Pilar; Pumarola, Tomàs; Antón, Andrés

    2018-05-25

    Influenza (FLUV) and human respiratory syncytial (HRSV) viruses are etiological agents of respiratory infections that cause a significant morbidity and mortality worldwide. A rapid and accurate diagnosis of these respiratory viruses is essential for an appropriate patient management. Molecular tests are the best detection option due to their high sensitivity and specificity. Seegene's Allplex™ Respiratory Panel 1 (Allplex RP1) is a real-time one-step RT-PCR assay for the simultaneous detection of FLUAV, FLUBV, HRSV-A and HRSV-B. In addition, it allows the determination of FLUAV subtype (H1, H3 and H1pdm09). This study aims to evaluate Allplex RP1 as a rapid molecular test for the detection of FLUAV, FLUBV, HRSV-A and HRSV-B viruses. The Allplex RP1 assay will be compared with other two commercial molecular assays, Prodesse ProFlu+ and ProFAST+ (Hologic, Madison, WI, USA), and GeneXpert Flu/RSV XC (Cepheid, USA). Allplex RP1, ProFlu+ and GeneXpert tests showed 95%, 91% and 96% of accuracy; and 94%, 88% and 95% of sensitivity, respectively. Moreover, Allplex RP1 showed a FLUAV subtype sensitivity of 91% and 88% for FLUAV-H1pdm09 and FLUAV-H3 respectively, and ProFAST+ assay showed sensitivities of 100% for both targets. The three assays showed a 100% of specificity and PPV, while the NPV were 84%, 73% and 86% for Allplex RP1, Prodesse and GeneXpert, respectively. In this study, Seegene's Allplex RP1 assay showed to be highly sensitive, specific, and suitable for detection of FLUV and HRSV, including FLUAV subtyping. In addition, it is also a hands-on-time saving assay due to the automated nucleic acid extraction and PCR setup. Copyright © 2018. Published by Elsevier B.V.

  1. Label-Enhanced Surface Plasmon Resonance: A New Concept for Improved Performance in Optical Biosensor Analysis

    PubMed Central

    Granqvist, Niko; Hanning, Anders; Eng, Lars; Tuppurainen, Jussi; Viitala, Tapani

    2013-01-01

    Surface plasmon resonance (SPR) is a well-established optical biosensor technology with many proven applications in the study of molecular interactions as well as in surface and material science. SPR is usually applied in the label-free mode which may be advantageous in cases where the presence of a label may potentially interfere with the studied interactions per se. However, the fundamental challenges of label-free SPR in terms of limited sensitivity and specificity are well known. Here we present a new concept called label-enhanced SPR, which is based on utilizing strongly absorbing dye molecules in combination with the evaluation of the full shape of the SPR curve, whereby the sensitivity as well as the specificity of SPR is significantly improved. The performance of the new label-enhanced SPR method was demonstrated by two simple model assays: a small molecule assay and a DNA hybridization assay. The small molecule assay was used to demonstrate the sensitivity enhancement of the method, and how competitive assays can be used for relative affinity determination. The DNA assay was used to demonstrate the selectivity of the assay, and the capabilities in eliminating noise from bulk liquid composition variations. PMID:24217357

  2. A Novel Isothermal Assay of Borrelia burgdorferi by Recombinase Polymerase Amplification with Lateral Flow Detection.

    PubMed

    Liu, Wei; Liu, Hui-Xin; Zhang, Lin; Hou, Xue-Xia; Wan, Kang-Lin; Hao, Qin

    2016-08-03

    A novel isothermal detection for recombinase polymerase amplification with lateral flow (LF-RPA) was established for Borrelia burgdorferi (B. burgdorferi) detection in this study. This assay with high sensitivity and specificity can get a visible result without any additional equipment in 30 min. We designed a pair of primers according to recA gene of B. burgdorferi strains and a methodology evaluation was performed. The results showed that the RPA assay based on the recA gene was successfully applied in B. burgdorferi detection, and its specific amplification was only achieved from the genomic DNA of B. burgdorferi. The detection limit of the new assay was about 25 copies of the B. burgdorferi genomic DNA. Twenty Lyme borreliosis patients' serum samples were detected by LF-RPA assay, real-time qPCR and nested-PCR. Results showed the LF-RPA assay is more effective than nested-PCR for its shorter reaction time and considerably higher detection rate. This method is of great value in clinical rapid detection for Lyme borreliosis. Using the RPA assay might be a megatrend for DNA detection in clinics and endemic regions.

  3. Evaluating pleural ADA, ADA2, IFN-γ and IGRA for diagnosing tuberculous pleurisy.

    PubMed

    Keng, Li-Ta; Shu, Chin-Chung; Chen, Jason Yao-Ping; Liang, Sheng-Kai; Lin, Ching-Kai; Chang, Lih-Yu; Chang, Chia-Hao; Wang, Jann-Yuan; Yu, Chong-Jen; Lee, Li-Na

    2013-10-01

    Conventional methods for diagnosing tuberculous pleurisy (TB pleurisy) are either invasive or have a long turn-around-time. Performances of pleural adenosine deaminase (ADA), ADA2, interferon-gamma (IFN-γ), and interferon-gamma release assays (IGRA) as diagnostic tools for TB pleurisy were evaluated. Eighty-eight patients with lymphocyte-predominant pleural exudates between June 2010 and March 2011, including 31 with clinically diagnosed TB pleurisy, were prospectively studied. Pleural ADA and ADA2 activity were measured by colorimetric method, IFN-γ levels by enzyme-linked immuno-sorbent assay, and IGRA by enzyme-linked immuno-spot (T-SPOT.TB) assay. Pleural ADA, ADA2, and IFN-γ levels, but not the proportion of positive T-SPOT.TB assay, were significantly higher in patients with TB pleurisy than in those without TB pleurisy. The area under the receiver-operating-characteristic (ROC) curve was 0.920, 0.893, 0.875, and 0.544 for IFN-γ, ADA2, ADA, and T-SPOT.TB assay, respectively. The combination of ADA ≥ 40 IU/L and IFN-γ ≥ 75 pg/mL yielded a specificity of 100%. Pleural ADA, ADA2 and IFN-γ, but not T-SPOT.TB assay, are all sensitive and specific for TB pleurisy. In patients with lymphocyte-predominant pleural exudates, ADA ≥ 40 IU/L and IFN-γ ≥ 75 pg/mL in pleural effusion imply a very high probability of TB pleurisy. Copyright © 2013 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  4. Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25.

    PubMed

    Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan

    2013-11-01

    The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg(-1) GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25.

  5. Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25

    PubMed Central

    Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan

    2013-01-01

    The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg−1 GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25. PMID:24804053

  6. Development and evaluation of antibody-capture immunoassays for detection of Lassa virus nucleoprotein-specific immunoglobulin M and G.

    PubMed

    Gabriel, Martin; Adomeh, Donatus I; Ehimuan, Jacqueline; Oyakhilome, Jennifer; Omomoh, Emmanuel O; Ighodalo, Yemisi; Olokor, Thomas; Bonney, Kofi; Pahlmann, Meike; Emmerich, Petra; Lelke, Michaela; Brunotte, Linda; Ölschläger, Stephan; Thomé-Bolduan, Corinna; Becker-Ziaja, Beate; Busch, Carola; Odia, Ikponmwosa; Ogbaini-Emovon, Ephraim; Okokhere, Peter O; Okogbenin, Sylvanus A; Akpede, George O; Schmitz, Herbert; Asogun, Danny A; Günther, Stephan

    2018-03-01

    The classical method for detection of Lassa virus-specific antibodies is the immunofluorescence assay (IFA) using virus-infected cells as antigen. However, IFA requires laboratories of biosafety level 4 for assay production and an experienced investigator to interpret the fluorescence signals. Therefore, we aimed to establish and evaluate enzyme-linked immunosorbent assays (ELISA) using recombinant Lassa virus nucleoprotein (NP) as antigen. The IgM ELISA is based on capturing IgM antibodies using anti-IgM, and the IgG ELISA is based on capturing IgG antibody-antigen complexes using rheumatoid factor or Fc gamma receptor CD32a. Analytical and clinical evaluation was performed with 880 sera from Lassa fever endemic (Nigeria) and non-endemic (Ghana and Germany) areas. Using the IFA as reference method, we observed 91.5-94.3% analytical accuracy of the ELISAs in detecting Lassa virus-specific antibodies. Evaluation of the ELISAs for diagnosis of Lassa fever on admission to hospital in an endemic area revealed a clinical sensitivity for the stand-alone IgM ELISA of 31% (95% CI 25-37) and for combined IgM/IgG detection of 26% (95% CI 21-32) compared to RT-PCR. The specificity of IgM and IgG ELISA was estimated at 96% (95% CI 93-98) and 100% (95% CI 99-100), respectively, in non-Lassa fever patients from non-endemic areas. In patients who seroconverted during follow-up, Lassa virus-specific IgM and IgG developed simultaneously rather than sequentially. Consistent with this finding, isolated IgM reactivity, i.e. IgM in the absence of IgG, had no diagnostic value. The ELISAs are not equivalent to RT-PCR for early diagnosis of Lassa fever; however, they are of value in diagnosing patients at later stage. The IgG ELISA may be useful for epidemiological studies and clinical trials due its high specificity, and the higher throughput rate and easier operation compared to IFA.

  7. Evaluation of FRET real-time PCR assay for rapid detection and differentiation of Plasmodium species in returning travellers and migrants

    PubMed Central

    Safeukui, Innocent; Millet, Pascal; Boucher, Sébastien; Melinard, Laurence; Fregeville, Frédéric; Receveur, Marie-Catherine; Pistone, Thierry; Fialon, Pierre; Vincendeau, Philippe; Fleury, Hervé; Malvy, Denis

    2008-01-01

    Background A simple real-time PCR assay using one set of primer and probe for rapid, sensitive and quantitative detection of Plasmodium species, with simultaneous differentiation of Plasmodium falciparum from the three other Plasmodium species (Plasmodium vivax, Plasmodium ovale and Plasmodium malariae) in febrile returning travellers and migrants was developed and evaluated. Methods Consensus primers were used to amplify a species-specific region of the multicopy 18S rRNA gene, and fluorescence resonance energy transfer hybridization probes were used for detection in a LightCycler platform (Roche). The anchor probe sequence was designed to be perfect matches to the 18S rRNA gene of the fourth Plasmodium species, while the acceptor probe sequence was designed for P. falciparum over a region containing one mismatched, which allowed differentiation of the three other Plasmodium species. The performance characteristics of the real-time PCR assay were compared with those of conventional PCR and microscopy-based diagnosis from 119 individuals with a suspected clinical diagnostic of imported malaria. Results Blood samples with parasite densities less than 0.01% were all detected, and analytical sensitivity was 0.5 parasite per PCR reaction. The melt curve means Tms (standard deviation) in clinical isolates were 60.5°C (0.6°C) for P. falciparum infection and 64.6°C (1.8°C) for non-P. falciparum species. These Tms values of the P. falciparum or non-P. falciparum species did not vary with the geographic origin of the parasite. The real-time PCR results correlated with conventional PCR using both genus-specific (Kappa coefficient: 0.95, 95% confidence interval: 0.9 – 1) or P. falciparum-specific (0.91, 0.8 – 1) primers, or with the microscopy results (0.70, 0.6 – 0.8). The real-time assay was 100% sensitive and specific for differentiation of P. falciparum to non-P. falciparum species, compared with conventional PCR or microscopy. The real-time PCR assay can also detect individuals with mixed infections (P. falciparum and non-P. falciparum sp.) in the same sample. Conclusion This real-time PCR assay with melting curve analysis is rapid, and specific for the detection and differentiation of P. falciparum to other Plasmodium species. The suitability for routine use of this assay in clinical diagnostic laboratories is discussed. PMID:18442362

  8. Serodiagnosis of bovine leptospirosis by IgG-enzyme-linked immunosorbent assay and latex agglutination test.

    PubMed

    Senthilkumar, T M A; Subathra, M; Ramadass, P; Ramaswamy, V

    2010-02-01

    The efficacy of a recombinant leptospiral outer membrane protein LipL41 as an antigen for conducting IgG-Enzyme linked immunosorbent assay (ELISA) and latex agglutination test (LAT) for serodiagnosis of bovine leptospirosis was evaluated. The recombinant LipL41 antigen developed and used for detecting the antibodies was specific in detection of the pathogenic serovars of Leptospira, as the expression of the LipL41 antigen is restricted only to pathogenic leptospires. A total of 430 bovine serum samples were subjected to IgG-ELISA and LAT, and the sensitivity and specificity were assessed in comparison with microscopic agglutination test (MAT). The sensitivity and specificity of IgG-ELISA and LAT were 86.84% and 93.16%, and 95.42% and 98.33% respectively. Both the tests are found to be sensitive, specific and concurred with the standard MAT. The study concluded that the rLipL41 protein could be used as a potential diagnostic antigen in different assay formats for bovine leptospirosis.

  9. Development and Validation of a Multiplex PCR for Detection of Scedosporium spp. in Respiratory Tract Specimens from Patients with Cystic Fibrosis▿

    PubMed Central

    Harun, Azian; Blyth, Christopher C.; Gilgado, Felix; Middleton, Peter; Chen, Sharon C.-A.; Meyer, Wieland

    2011-01-01

    The emergence of Scedosporium infections in diverse groups of individuals, which are often treatment refractory, warrants timely and accurate laboratory diagnosis. Species- or group-specific primers based on internal transcribed spacer (ITS) sequence polymorphisms were designed for Scedosporium aurantiacum, Scedosporium dehoogii, Scedosporium prolificans, Pseudallescheria boydii species complex (former clade 5)/Pseudallescheria apiosperma (formerly classified as S. apiospermum sensu lato) and Pseudallescheria minutispora. Primers for S. aurantiacum, S. prolificans, and P. boydii species complex/P. apiosperma were incorporated into a multiplex PCR assay for the detection and identification of the three major clinically important Scedosporium species and validated using sputum specimens collected from patients seen at a major Australian cystic fibrosis clinic. The multiplex PCR assay showed 100% specificity in identifying the three major clinically relevant Scedosporium species from pure culture. When evaluated using DNA extracts from sputa, sensitivity and specificity of the multiplex PCR assay were 62.1% and 97.2%, respectively. This highly species-specific multiplex PCR assay offers a rapid and simple method of detection of the most clinically important Scedosporium species in respiratory tract specimens. PMID:21325557

  10. Development of an Escherichia coli K12-specific quantitative polymerase chain reaction assay and DNA isolation suited to biofilms associated with iron drinking water pipe corrosion products.

    PubMed

    Lu, Jingrang; Gerke, Tammie L; Buse, Helen Y; Ashbolt, Nicholas J

    2014-12-01

    A quantitative polymerase chain reaction assay (115 bp amplicon) specific to Escherichia coli K12 with an ABI(TM) internal control was developed based on sequence data encoding the rfb gene cluster. Assay specificity was evaluated using three E. coli K12 strains (ATCC W3110, MG1655 & DH1), 24 non-K12 E. coli and 23 bacterial genera. The biofilm detection limit was 10(3) colony-forming units (CFU) E. coli K12 mL(-1), but required a modified protocol, which included a bio-blocker Pseudomonas aeruginosa with ethylenediaminetetraacetic acid buffered to pH 5 prior to cell lysis/DNA extraction. The novel protocol yielded the same sensitivity for drinking water biofilms associated with Fe3O4 (magnetite)-coated SiO2 (quartz) grains and biofilm-surface iron corrosion products from a drinking water distribution system. The novel DNA extraction protocol and specific E. coli K12 assay are sensitive and robust enough for detection and quantification within iron drinking water pipe biofilms, and are particularly well suited for studying enteric bacterial interactions within biofilms.

  11. Evaluation of a Cryptococcal antigen Lateral Flow Assay in serum and cerebrospinal fluid for rapid diagnosis of cryptococcosis in Colombia.

    PubMed

    Cáceres, Diego H; Zuluaga, Alejandra; Tabares, Ángela M; Chiller, Tom; González, Ángel; Gómez, Beatriz L

    2017-12-21

    A Lateral Flow Assay to detect cryptococcal antigen (CrAg® LFA) in serum and cerebrospinal fluid for the rapid diagnosis of cryptococcosis was evaluated. A retrospective validation was performed. Sensitivity and specificity of the CrAg® LFA was 100%. High concordance (kappa index=1.0) between Cryptococcal Antigen Latex Agglutination System (CALAS®) and CrAg® LFA was observed. CrAg® LFA showed higher analytical sensitivity for detecting low concentrations of cryptococcal antigen.

  12. Evaluation of a Cryptococcal antigen Lateral Flow Assay in serum and cerebrospinal fluid for rapid diagnosis of cryptococcosis in Colombia

    PubMed Central

    Cáceres, Diego H.; Zuluaga, Alejandra; Tabares, Ángela M.; Chiller, Tom; González, Ángel; Gómez, Beatriz L.

    2017-01-01

    ABSTRACT A Lateral Flow Assay to detect cryptococcal antigen (CrAg® LFA) in serum and cerebrospinal fluid for the rapid diagnosis of cryptococcosis was evaluated. A retrospective validation was performed. Sensitivity and specificity of the CrAg® LFA was 100%. High concordance (kappa index=1.0) between Cryptococcal Antigen Latex Agglutination System (CALAS®) and CrAg® LFA was observed. CrAg® LFA showed higher analytical sensitivity for detecting low concentrations of cryptococcal antigen. PMID:29267584

  13. Flow cytometric immunobead assay for quantitative detection of platelet autoantibodies in immune thrombocytopenia patients.

    PubMed

    Zhai, Juping; Ding, Mengyuan; Yang, Tianjie; Zuo, Bin; Weng, Zhen; Zhao, Yunxiao; He, Jun; Wu, Qingyu; Ruan, Changgeng; He, Yang

    2017-10-23

    Platelet autoantibody detection is critical for immune thrombocytopenia (ITP) diagnosis and prognosis. Therefore, we aimed to establish a quantitative flow cytometric immunobead assay (FCIA) for ITP platelet autoantibodies evaluation. Capture microbeads coupled with anti-GPIX, -GPIb, -GPIIb, -GPIIIa and P-selectin antibodies were used to bind the platelet-bound autoantibodies complex generated from plasma samples of 250 ITP patients, 163 non-ITP patients and 243 healthy controls, a fluorescein isothiocyanate (FITC)-conjugated secondary antibody was the detector reagent and mean fluorescence intensity (MFI) signals were recorded by flow cytometry. Intra- and inter-assay variations of the quantitative FCIA assay were assessed. Comparisons of the specificity, sensitivity and accuracy between quantitative and qualitative FCIA or monoclonal antibody immobilization of platelet antigen (MAIPA) assay were performed. Finally, treatment process was monitored by our quantitative FCIA in 8 newly diagnosed ITPs. The coefficient of variations (CV) of the quantitative FCIA assay were respectively 9.4, 3.8, 5.4, 5.1 and 5.8% for anti-GPIX, -GPIb, -GPIIIa, -GPIIb and -P-selectin autoantibodies. Elevated levels of autoantibodies against platelet glycoproteins GPIX, GPIb, GPIIIa, GPIIb and P-selectin were detected by our quantitative FCIA in ITP patients compared to non-ITP patients or healthy controls. The sensitivity, specificity and accuracy of our quantitative assay were respectively 73.13, 81.98 and 78.65% when combining all 5 autoantibodies, while the sensitivity, specificity and accuracy of MAIPA assay were respectively 41.46, 90.41 and 72.81%. A quantitative FCIA assay was established. Reduced levels of platelet autoantibodies could be confirmed by our quantitative FCIA in ITP patients after corticosteroid treatment. Our quantitative assay is not only good for ITP diagnosis but also for ITP treatment monitoring.

  14. Development of Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid and Sensitive Identification of Ostrich Meat

    PubMed Central

    Abdulmawjood, Amir; Grabowski, Nils; Fohler, Svenja; Kittler, Sophie; Nagengast, Helga; Klein, Guenter

    2014-01-01

    Animal species identification is one of the primary duties of official food control. Since ostrich meat is difficult to be differentiated macroscopically from beef, therefore new analytical methods are needed. To enforce labeling regulations for the authentication of ostrich meat, it might be of importance to develop and evaluate a rapid and reliable assay. In the present study, a loop-mediated isothermal amplification (LAMP) assay based on the cytochrome b gene of the mitochondrial DNA of the species Struthio camelus was developed. The LAMP assay was used in combination with a real-time fluorometer. The developed system allowed the detection of 0.01% ostrich meat products. In parallel, a direct swab method without nucleic acid extraction using the HYPLEX LPTV buffer was also evaluated. This rapid processing method allowed detection of ostrich meat without major incubation steps. In summary, the LAMP assay had excellent sensitivity and specificity for detecting ostrich meat and could provide a sampling-to-result identification-time of 15 to 20 minutes. PMID:24963709

  15. Laboratory evaluation of the Liat HIV Quant (IQuum) whole-blood and plasma HIV-1 viral load assays for point-of-care testing in South Africa.

    PubMed

    Scott, Lesley; Gous, Natasha; Carmona, Sergio; Stevens, Wendy

    2015-05-01

    Point-of-care (POC) HIV viral load (VL) testing offers the potential to reduce turnaround times for antiretroviral therapy monitoring, offer near-patient acute HIV diagnosis in adults, extend existing centralized VL services, screen women in labor, and prompt pediatrics to early treatment. The Liat HIV Quant plasma and whole-blood assays, prerelease version, were evaluated in South Africa. The precision, accuracy, linearity, and agreement of the Liat HIV Quant whole-blood and plasma assays were compared to those of reference technologies (Roche CAP CTMv2.0 and Abbott RealTime HIV-1) on an HIV verification plasma panel (n = 42) and HIV clinical specimens (n = 163). HIV Quant plasma assay showed good performance, with a 2.7% similarity coefficient of variation (CV) compared to the Abbott assay and a 1.8% similarity CV compared to the Roche test on the verification panel, and 100% specificity. HIV Quant plasma had substantial agreement (pc [concordance correlation] = 0.96) with Roche on clinical specimens and increased variability (pc = 0.73) in the range of <3.0 log copies/ml range with the HIV Quant whole-blood assay. HIV Quant plasma assay had good linearity (2.0 to 5.0 log copies/ml; R(2) = 0.99). Clinical sensitivity at a viral load of 1,000 copies/ml of the HIV Quant plasma and whole-blood assays compared to that of the Roche assay (n = 94) was 100% (confidence interval [CI], 95.3% to 100%). The specificity of HIV Quant plasma was 88.2% (CI, 63.6% to 98.5%), and that for whole blood was 41.2% (CI, 18.4% to 67.1%). No virological failure (downward misclassification) was missed. Liat HIV Quant plasma assay can be interchanged with existing VL technology in South Africa. Liat HIV Quant whole-blood assay would be advantageous for POC early infant diagnosis at birth and adult adherence monitoring and needs to be evaluated further in this clinical context. LIAT cartridges currently require cold storage, but the technology is user-friendly and robust. Clinical cost and implementation modeling is required. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  16. Immune defence against HIV-1 infection in HIV-1-exposed seronegative persons.

    PubMed

    Schmechel, S C; Russell, N; Hladik, F; Lang, J; Wilson, A; Ha, R; Desbien, A; McElrath, M J

    2001-11-01

    Rare individuals who are repeatedly exposed to HIV-1 through unprotected sexual contact fail to acquire HIV-1 infection. These persons represent a unique study population to evaluate mechanisms by which HIV-1 replication is either prevented or controlled. We followed longitudinally a group of healthy HIV-1 seronegative persons each reporting repeated high-risk sexual activities with their HIV-1-infected partner at enrollment. The volunteers were primarily (90%) male homosexuals, maintaining high risk activities with their known infected partner (45%) or multiple other partners (61%). We evaluated the quantity and specificity of HIV-1-specific T cells in 31 exposed seronegatives (ES) using a IFN-gamma ELISPOT assay to enumerate T cells recognizing epitopes within HIV-1 Env, Gag, Pol and Nef. PBMC from only three of the 31 volunteers demonstrated ex vivo HIV-1-specific IFN-gamma secretion, in contrast to nearly 30% exhibiting cytolytic responses in previous studies. These findings suggest that if T cell responses in ES are induced by HIV-1 exposure, the frequency is at low levels in most of them, and below the level of detection using the ELISPOT assay. Alternative approaches to improve the sensitivity of detection may include use of dendritic cells as antigen-presenting cells in the ex vivo assay and more careful definition of the risk behavior and extent of HIV-1 exposure in conjunction with the evaluation of T cell responses.

  17. Development and evaluation of a Quadruplex Taq Man real-time PCR assay for simultaneous detection of clinical isolates of Enterococcus faecalis, Enterococcus faecium and their vanA and vanB genotypes.

    PubMed

    Naserpour Farivar, Taghi; Najafipour, Reza; Johari, Pouran; Aslanimehr, Masoumeh; Peymani, Amir; Jahani Hashemi, Hoasan; Mirzaui, Baman

    2014-10-01

    We developed and evaluated the utility of a quadruplex Taqman real-time PCR assay that allows simultaneous identification of vancomycin-resistant genotypes and clinically relevant enterococci. The specificity of the assay was tested using reference strains of vancomycin-resistant and susceptible enterococci. In total, 193 clinical isolates were identified and subsequently genotyped using a Quadruplex Taqman real-time PCR assay and melting curve analysis. Representative Quadruplex Taqman real-time PCR amplification curve were obtained for Enterococcus faecium, Enterococcus faecalis, vanA-containing E. faecium, vanB-containing E. faecalis. Phenotypic and genotypic analysis of the isolates gave same results for 82 enterococcal isolates, while in 5 isolates, they were inconsistent. We had three mixed strains, which were detected by the TaqMan real-time PCR assay and could not be identified correctly using phenotypic methods. Vancomycin resistant enterococci (VRE) genotyping and identification of clinically relevant enterococci were rapidly and correctly performed using TaqMan real-time multiplex real-time PCR assay.

  18. Development of an anti-dengue NS1 IgG ELISA to evaluate exposure to dengue virus.

    PubMed

    Nascimento, Eduardo J M; George, James K; Velasco, Melissa; Bonaparte, Matthew I; Zheng, Lingyi; DiazGranados, Carlos A; Marques, Ernesto T A; Huleatt, James W

    2018-07-01

    Dengue virus infection elicits immune responses to multiple viral antigens including antibodies to dengue non-structural protein 1 (NS1) which are rapidly induced and detected within days of infection. The recombinant, live, attenuated, tetravalent dengue vaccine (CYD-TDV; Sanofi Pasteur) uses the yellow fever vaccine virus as a back-bone but expresses dengue virus pre-membrane and envelop proteins. Since CYD-TDV does not express dengue NS1, we evaluated the utility of dengue NS1-specific IgG antibodies as biomarkers of dengue exposure in CYD-TDV recipients and controls. We optimized and evaluated a quantitative anti-dengue NS1 IgG enzyme-linked immunosorbent assay (ELISA). Parameters assessed included: accuracy, dilutability/linearity, precision, limit of quantitation and specificity. The assay specificity was further evaluated using Japanese Encephalitis virus, West Nile virus, Yellow Fever virus or Zika virus positive sera samples collected following confirmed infection or vaccination. Receiver-operating-characteristics (ROC) curves as well as sensitivity and specificity for discriminating previous dengue exposure were assessed using 1250 reference samples. Overall, the anti-dengue NS1 IgG ELISA was able to discriminate previous dengue exposure from non-exposure before vaccination with CYD-TDV (ROC area under the curve > 0.9). Assessment of paired samples from 2511 vaccinated participants showed high overall agreement (93%) between pre-vaccination and post-vaccination dengue serostatus classification based on the anti-dengue NS1 IgG ELISA. However, misclassification of dengue serostatus was observed after vaccination likely due to a combination of asymptomatic dengue infections, assay variability and a modest effect of CYD-TDV on the anti-dengue NS1 IgG ELISA readout. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Evaluating 6 ricin field detection assays.

    PubMed

    Slotved, Hans-Christian; Sparding, Nadja; Tanassi, Julia Tanas; Steenhard, Nina R; Heegaard, Niels H H

    2014-01-01

    This study presents data showing the performance of 6 commercial detection assays against ricin around concentrations specified as detection limits by the producers. A 2-fold dilution series of 20 ng/ml ricin was prepared and used for testing the lateral-flow kits: BADD, Pro Strips™, ENVI, RAID DX, Ricin BioThreat Alert, and IMASS™ device. Three of the 6 tested field assays (IMASS™ device, ENVI assay, and the BioThreat Alert assay) were able to detect ricin, although differences in the measured detection limits compared to the official detection limits and false-negative results were observed. We were not able to get the BADD, Pro Strips™, and RAID assays to function in our laboratory. We conclude that when purchasing a field responder assay, there is large variation in the specificity of the assays, and a number of in-house tests must be performed to ensure functionality.

  20. The performance of the SEPT9 gene methylation assay and a comparison with other CRC screening tests: A meta-analysis.

    PubMed

    Song, Lele; Jia, Jia; Peng, Xiumei; Xiao, Wenhua; Li, Yuemin

    2017-06-08

    The SEPT9 gene methylation assay is the first FDA-approved blood assay for colorectal cancer (CRC) screening. Fecal immunochemical test (FIT), FIT-DNA test and CEA assay are also in vitro diagnostic (IVD) tests used in CRC screening. This meta-analysis aims to review the SEPT9 assay performance and compare it with other IVD CRC screening tests. By searching the Ovid MEDLINE, EMBASE, CBMdisc and CJFD database, 25 out of 180 studies were identified to report the SEPT9 assay performance. 2613 CRC cases and 6030 controls were included, and sensitivity and specificity were used to evaluate its performance at various algorithms. 1/3 algorithm exhibited the best sensitivity while 2/3 and 1/1 algorithm exhibited the best balance between sensitivity and specificity. The performance of the blood SEPT9 assay is superior to that of the serum protein markers and the FIT test in symptomatic population, while appeared to be less potent than FIT and FIT-DNA tests in asymptomatic population. In conclusion, 1/3 algorithm is recommended for CRC screening, and 2/3 or 1/1 algorithms are suitable for early detection for diagnostic purpose. The SEPT9 assay exhibited better performance in symptomatic population than in asymptomatic population.

  1. Mesocosm Community Response Sensitivities to Specific Conductivity Comprised of Different Major Ions

    EPA Science Inventory

    Traditional toxicity test assays have been used to evaluate the relative sensitivity to different major ion mixtures as a proxy for understanding what the response of aquatic species growing in their natural environment would be during exposure to specific conductivity stress ema...

  2. Development of a One-Step Multiplex PCR Assay for Differential Detection of Major Mycobacterium Species

    PubMed Central

    Chae, Hansong; Han, Seung Jung; Kim, Su-Young; Ki, Chang-Seok; Huh, Hee Jae; Yong, Dongeun

    2017-01-01

    ABSTRACT The prevalence of tuberculosis continues to be high, and nontuberculous mycobacterial (NTM) infection has also emerged worldwide. Moreover, differential and accurate identification of mycobacteria to the species or subspecies level is an unmet clinical need. Here, we developed a one-step multiplex PCR assay using whole-genome analysis and bioinformatics to identify novel molecular targets. The aims of this assay were to (i) discriminate between the Mycobacterium tuberculosis complex (MTBC) and NTM using rv0577 or RD750, (ii) differentiate M. tuberculosis (M. tuberculosis) from MTBC using RD9, (iii) selectively identify the widespread M. tuberculosis Beijing genotype by targeting mtbk_20680, and (iv) simultaneously detect five clinically important NTM (M. avium, M. intracellulare, M. abscessus, M. massiliense, and M. kansasii) by targeting IS1311, DT1, mass_3210, and mkan_rs12360. An initial evaluation of the multiplex PCR assay using reference strains demonstrated 100% specificity for the targeted Mycobacterium species. Analytical sensitivity ranged from 1 to 10 pg for extracted DNA and was 103 and 104 CFU for pure cultures and nonhomogenized artificial sputum cultures, respectively, of the targeted species. The accuracy of the multiplex PCR assay was further evaluated using 55 reference strains and 94 mycobacterial clinical isolates. Spoligotyping, multilocus sequence analysis, and a commercial real-time PCR assay were employed as standard assays to evaluate the multiplex PCR assay with clinical M. tuberculosis and NTM isolates. The PCR assay displayed 100% identification agreement with the standard assays. Our multiplex PCR assay is a simple, convenient, and reliable technique for differential identification of MTBC, M. tuberculosis, M. tuberculosis Beijing genotype, and major NTM species. PMID:28659320

  3. Development of a One-Step Multiplex PCR Assay for Differential Detection of Major Mycobacterium Species.

    PubMed

    Chae, Hansong; Han, Seung Jung; Kim, Su-Young; Ki, Chang-Seok; Huh, Hee Jae; Yong, Dongeun; Koh, Won-Jung; Shin, Sung Jae

    2017-09-01

    The prevalence of tuberculosis continues to be high, and nontuberculous mycobacterial (NTM) infection has also emerged worldwide. Moreover, differential and accurate identification of mycobacteria to the species or subspecies level is an unmet clinical need. Here, we developed a one-step multiplex PCR assay using whole-genome analysis and bioinformatics to identify novel molecular targets. The aims of this assay were to (i) discriminate between the Mycobacterium tuberculosis complex (MTBC) and NTM using rv0577 or RD750, (ii) differentiate M. tuberculosis ( M. tuberculosis ) from MTBC using RD9, (iii) selectively identify the widespread M. tuberculosis Beijing genotype by targeting mtbk_20680 , and (iv) simultaneously detect five clinically important NTM ( M. avium , M. intracellulare , M. abscessus , M. massiliense , and M. kansasii ) by targeting IS 1311 , DT1, mass_3210 , and mkan_rs12360 An initial evaluation of the multiplex PCR assay using reference strains demonstrated 100% specificity for the targeted Mycobacterium species. Analytical sensitivity ranged from 1 to 10 pg for extracted DNA and was 10 3 and 10 4 CFU for pure cultures and nonhomogenized artificial sputum cultures, respectively, of the targeted species. The accuracy of the multiplex PCR assay was further evaluated using 55 reference strains and 94 mycobacterial clinical isolates. Spoligotyping, multilocus sequence analysis, and a commercial real-time PCR assay were employed as standard assays to evaluate the multiplex PCR assay with clinical M. tuberculosis and NTM isolates. The PCR assay displayed 100% identification agreement with the standard assays. Our multiplex PCR assay is a simple, convenient, and reliable technique for differential identification of MTBC, M. tuberculosis , M. tuberculosis Beijing genotype, and major NTM species. Copyright © 2017 American Society for Microbiology.

  4. Development and Characterization of Probe-Based Real Time Quantitative RT-PCR Assays for Detection and Serotyping of Foot-And-Mouth Disease Viruses Circulating in West Eurasia

    PubMed Central

    Jamal, Syed M.; Belsham, Graham J.

    2015-01-01

    Rapid and accurate diagnosis of foot-and-mouth disease (FMD) and virus serotyping are of paramount importance for control of this disease in endemic areas where vaccination is practiced. Ideally this virus characterization should be achieved without the need for virus amplification in cell culture. Due to the heterogeneity of FMD viruses (FMDVs) in different parts of the world, region specific diagnostic tests are required. In this study, hydrolysable probe-based real time reverse transcription quantitative polymerase chain reaction (RT-qPCR) assays were developed for specific detection and serotyping of the FMDVs currently circulating in West Eurasia. These assays were evaluated, in parallel with pan-FMDV diagnostic assays and earlier serotype-specific assays, using field samples originating from Pakistan and Afghanistan containing FMD viruses belonging to different sublineages of O-PanAsia, A-Iran05 and Asia-1 (Group-II and Group-VII (Sindh-08)). In addition, field samples from Iran and Bulgaria, containing FMDVs belonging to the O-PanAsiaANT-10 sublineage were also tested. Each of the three primer/probe sets was designed to be specific for just one of the serotypes O, A and Asia-1 of FMDV and detected the RNA from the target viruses with cycle threshold (CT) values comparable with those obtained with the serotype-independent pan-FMDV diagnostic assays. No cross-reactivity was observed in these assays between the heterotypic viruses circulating in the region. The assays reported here have higher diagnostic sensitivity (100% each for serotypes O and Asia-1, and 92% [95% CI = 81.4–100%] for serotype A positive samples) and specificity (100% each for serotypes O, A and Asia-1 positive samples) for the viruses currently circulating in West Eurasia compared to the serotyping assays reported earlier. Comparisons of the sequences of the primers and probes used in these assays and the corresponding regions of the circulating viruses provided explanations for the poor recognition of some of the viruses by the earlier assays. These new assays should help in the early detection and typing of serotype O, A and Asia-1 FMDVs circulating in West Eurasia to enable improved disease control. PMID:26270532

  5. Development and Characterization of Probe-Based Real Time Quantitative RT-PCR Assays for Detection and Serotyping of Foot-And-Mouth Disease Viruses Circulating in West Eurasia.

    PubMed

    Jamal, Syed M; Belsham, Graham J

    2015-01-01

    Rapid and accurate diagnosis of foot-and-mouth disease (FMD) and virus serotyping are of paramount importance for control of this disease in endemic areas where vaccination is practiced. Ideally this virus characterization should be achieved without the need for virus amplification in cell culture. Due to the heterogeneity of FMD viruses (FMDVs) in different parts of the world, region specific diagnostic tests are required. In this study, hydrolysable probe-based real time reverse transcription quantitative polymerase chain reaction (RT-qPCR) assays were developed for specific detection and serotyping of the FMDVs currently circulating in West Eurasia. These assays were evaluated, in parallel with pan-FMDV diagnostic assays and earlier serotype-specific assays, using field samples originating from Pakistan and Afghanistan containing FMD viruses belonging to different sublineages of O-PanAsia, A-Iran05 and Asia-1 (Group-II and Group-VII (Sindh-08)). In addition, field samples from Iran and Bulgaria, containing FMDVs belonging to the O-PanAsiaANT-10 sublineage were also tested. Each of the three primer/probe sets was designed to be specific for just one of the serotypes O, A and Asia-1 of FMDV and detected the RNA from the target viruses with cycle threshold (CT) values comparable with those obtained with the serotype-independent pan-FMDV diagnostic assays. No cross-reactivity was observed in these assays between the heterotypic viruses circulating in the region. The assays reported here have higher diagnostic sensitivity (100% each for serotypes O and Asia-1, and 92% [95% CI = 81.4-100%] for serotype A positive samples) and specificity (100% each for serotypes O, A and Asia-1 positive samples) for the viruses currently circulating in West Eurasia compared to the serotyping assays reported earlier. Comparisons of the sequences of the primers and probes used in these assays and the corresponding regions of the circulating viruses provided explanations for the poor recognition of some of the viruses by the earlier assays. These new assays should help in the early detection and typing of serotype O, A and Asia-1 FMDVs circulating in West Eurasia to enable improved disease control.

  6. Evaluation of the LightCycler Staphylococcus MGRADE Kits on Positive Blood Cultures That Contained Gram-Positive Cocci in Clusters

    PubMed Central

    Shrestha, Nabin K.; Tuohy, Marion J.; Padmanabhan, Ravindran A.; Hall, Gerri S.; Procop, Gary W.

    2005-01-01

    We evaluated the Roche LightCycler Staphylococcus MGRADE kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci. PMID:16333115

  7. Evaluation of the LightCycler Staphylococcus M GRADE kits on positive blood cultures that contained gram-positive cocci in clusters.

    PubMed

    Shrestha, Nabin K; Tuohy, Marion J; Padmanabhan, Ravindran A; Hall, Gerri S; Procop, Gary W

    2005-12-01

    We evaluated the Roche LightCycler Staphylococcus M(GRADE) kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci.

  8. Development and comparative evaluation of SYBR Green I-based one-step real-time RT-PCR assay for detection and quantification of West Nile virus in human patients.

    PubMed

    Kumar, Jyoti S; Saxena, Divyasha; Parida, Manmohan

    2014-01-01

    The recent outbreaks of West Nile Virus (WNV) in the Northeastern American continents and other regions of the world have made it essential to develop an efficient protocol for surveillance of WN virus. Nucleic acid based techniques like, RT-PCR have the advantage of sensitivity, specificity and rapidity. A one step single tube Env gene specific real-time RT-PCR was developed for early and reliable clinical diagnosis of WNV infection in clinical samples. The applicability of this assay for clinical diagnosis was validated with 105 suspected acute-phase serum and plasma samples from the recent epidemic of mysterious fever in Tamil Nadu, India in 2009-10. The comparative evaluation revealed the higher sensitivity of real-time RT-PCR assay by picking up 4 additional samples with low copy number of template in comparison to conventional RT-PCR. All the real-time positive samples further confirmed by CDC reported TaqMan real-time RT-PCR and quantitative real-time RT-PCR assays for the simultaneous detection of WNV lineage 1 and 2 strains. The quantitation of the viral load samples was done using a standard curve. These findings demonstrated that the assay has the potential usefulness for clinical diagnosis due to detection and quantification of WNV in acute-phase patient serum samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Fasciola hepatica saposin-like-2 protein based ELISA for the serodiagnosis of chronic human fascioliasis

    PubMed Central

    Figueroa-Santiago, Olgary; Delgado, Bonnibel; Espino, Ana M.

    2011-01-01

    An indirect enzyme-linked immunosorbent assay (ELISA) was developed and evaluated for its diagnostic ability to detect human IgG antibodies against Fasciola hepatica saposin-like protein-2. The assay was compared with an indirect ELISA with excretory-secretory products (FhES) from adult F. hepatica. In an analysis of the sera of 37 patients infected with F. hepatica, 40 patients with other parasitic infections, and 50 healthy controls, the sensitivity of both ELISA assays was 100%. However, the FhSAP2-based ELISA was more specific (95.6%) than the FhES-ELISA (91.9%). These results demonstrated that FhSAP2 can be used in the serodiagnosis of chronic human fascioliasis with additional advantage that is relative cheap and easy to produce. Studies are in progress to evaluate this FhSAP2-ELISA assay in a large-scale prevalence surveys in endemic areas. PMID:21683266

  10. Evaluation of ColorPAC Giardia/Cryptosporidium Rapid Assay and ProSpecT Giardia/Cryptosporidium Microplate Assay for Detection of Giardia and Cryptosporidium in Fecal Specimens

    PubMed Central

    Katanik, M. T.; Schneider, S. K.; Rosenblatt, J. E.; Hall, G. S.; Procop, G. W.

    2001-01-01

    Detection of Giardia and Cryptosporidium in clinical stool specimens using the ColorPAC and ProSpecT enzyme immunoassays revealed 98.7% agreement for Giardia detection and 98.1% agreement for Cryptosporidium detection. Sensitivities were uniformly 100%. The specificities of the ColorPAC immunoassay for Giardia and Cryptosporidium detection were 100 and 99.5%, respectively, and those for the ProSpecT assay were 98.4 and 98.6%, respectively. The false-positive reactions with the ProSpecT assay occurred with specimens that were grossly bloody. PMID:11724874

  11. Potency assay development for cellular therapy products: an ISCT review of the requirements and experiences in the industry.

    PubMed

    Bravery, Christopher A; Carmen, Jessica; Fong, Timothy; Oprea, Wanda; Hoogendoorn, Karin H; Woda, Juliana; Burger, Scott R; Rowley, Jon A; Bonyhadi, Mark L; Van't Hof, Wouter

    2013-01-01

    The evaluation of potency plays a key role in defining the quality of cellular therapy products (CTPs). Potency can be defined as a quantitative measure of relevant biologic function based on the attributes that are linked to relevant biologic properties. To achieve an adequate assessment of CTP potency, appropriate in vitro or in vivo laboratory assays and properly controlled clinical data need to be created. The primary objective of a potency assay is to provide a mechanism by which the manufacturing process and the final product for batch release are scrutinized for quality, consistency and stability. A potency assay also provides the basis for comparability assessment after process changes, such as scale-up, site transfer and new starting materials (e.g., a new donor). Potency assays should be in place for early clinical development, and validated assays are required for pivotal clinical trials. Potency is based on the individual characteristics of each individual CTP, and the adequacy of potency assays will be evaluated on a case-by-case basis by regulatory agencies. We provide an overview of the expectations and challenges in development of potency assays specific for CTPs; several real-life experiences from the cellular therapy industry are presented as illustrations. The key observation and message is that aggressive early investment in a solid potency evaluation strategy can greatly enhance eventual CTP deployment because it can mitigate the risk of costly product failure in late-stage development. Copyright © 2013. Published by Elsevier Inc.

  12. [Assays of HbA1c and Amadori products in human biology].

    PubMed

    Gillery, P

    2014-09-01

    Different Amadori products, formed during the early steps of the non-enzymatic glycation of proteins, may be assayed in current practice in human biology. The most important marker is HbA1c, resulting from the binding of glucose to the N-terminal extremity of HbA beta chains. HbA1c may be evaluated by various techniques (ion exchange or affinity high performance liquid chromatography, capillary electrophoresis, immunoassay, enzymatic technique) and is considered the best marker of diabetic patient survey. Due to its irreversible and cumulative formation, it provides a retrospective information on the glycemic balance over the four to eight weeks preceding blood collection. It benefits from an international standardization, based on a reference method using liquid chromatography coupled to capillary electrophoresis or mass spectrometry, maintained by an international network of reference laboratories. When HbA1c assay cannot be used (anemia, hemolysis, hemoglobinopathy) or when a shorter period of glycemic equilibrium must be evaluated (child and adolescent, pregnancy, therapeutic changes), other Amadori products may be assayed, like plasma fructosamine (all plasma glycated proteins) or glycated albumin. Nevertheless, these assays are less used in practice, because their semiological value has been less evidenced. Besides, fructosamine assay lacks specificity, and glycated albumin assay has been described recently. An expanding use of HbA1c assay is expected, especially for the diagnosis of diabetes mellitus and the evaluation of other risks, especially cardiovascular ones. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  13. Molecular and immunological tools for the evaluation of the cellular immune response in the neotropical monkey Saimiri sciureus, a non-human primate model for malaria research.

    PubMed

    Riccio, Evelyn K P; Pratt-Riccio, Lilian R; Bianco-Júnior, Cesare; Sanchez, Violette; Totino, Paulo R R; Carvalho, Leonardo J M; Daniel-Ribeiro, Cláudio Tadeu

    2015-04-18

    The neotropical, non-human primates (NHP) of the genus Saimiri and Aotus are recommended by the World Health Organization as experimental models for the study of human malaria because these animals can be infected with the same Plasmodium that cause malaria in humans. However, one limitation is the lack of immunological tools to assess the immune response in these models. The present study focuses on the development and comparative use of molecular and immunological methods to evaluate the cellular immune response in Saimiri sciureus. Blood samples were obtained from nineteen uninfected Saimiri. Peripheral blood mononuclear cells (PBMC) from these animals and splenocytes from one splenectomized animal were cultured for 6, 12, 18, 24, 48, 72 and 96 hrs in the presence of phorbol-12-myristate-13-acetate and ionomycin. The cytokine levels in the supernatant were detected using human and NHP cytometric bead array Th1/Th2 cytokine kits, the Bio-Plex Pro Human Cytokine Th1/Th2 Assay, enzyme-linked immunosorbent assay, enzyme-linked immunospot assays and intracellular cytokine secretion assays. Cytokine gene expression was examined through TaqMan® Gene Expression Real-Time PCR using predesigned human gene-specific primers and probes or primers and probes designed based on published S. sciureus cytokine sequences. The use of five assays based on monoclonal antibodies specific for human cytokines facilitated the detection of IL-2, IL-4 and/or IFN-γ. TaqMan array plates facilitated the detection of 12 of the 28 cytokines assayed. However, only seven cytokines (IL-1A, IL-2, IL-10, IL-12B, IL-17, IFN-β, and TNF) presented relative expression levels of at least 70% of the gene expression observed in human PBMC. The use of primers and probes specific for S. sciureus cytokines facilitated the detection of transcripts that showed relative expression below the threshold of 70%. The most efficient evaluation of cytokine gene expression, in PBMC and splenocytes, was observed after 6-12 hrs of culture, except for LTA in PBMC, whose expression was best analysed after 24 hrs of culture. Real-time PCR facilitates the analysis of a large number of cytokines altered during malaria infection, and this technique is considered the best tool for the evaluation of the cellular immune response in S. sciureus.

  14. A European multicenter study on the analytical performance of the VERIS HBV assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Development of Purification Protocol Specific for Bacteriocin 105B

    DTIC Science & Technology

    2017-02-09

    determined to exhibit activity against a pathogenic organism of interest to the Army, Bacillus anthracis Sterne, a surrogate of the active form of...employment in future assays and development into a platform, such as a textile, that relays antimicrobial activity . 15. SUBJECT TERMS 105B...Purification with Ion Exchange Column Chromatography. Representative activity drop test assay evaluating activity of fractions collected from ion

  16. Evaluation of a commercial enzyme-linked immunosorbent assay for detection of antibodies against the H5 subtype of Influenza A virus in waterfowl

    USDA-ARS?s Scientific Manuscript database

    Serologic tools for rapid testing of subtype-specific influenza A (IA) virus antibody in wild birds and poultry are limited. In the current study, the ID Screen Influenza H5 Antibody Competition enzyme-linked immunosorbent assay (ELISA) was tested for the detection of antibodies to the H5 subtype o...

  17. Detecting West Nile Virus in Owls and Raptors by an Antigen-capture Assay

    PubMed Central

    Campbell, Douglas G.; Barker, Ian K.; Lindsay, Robbin; Hunter, Bruce

    2004-01-01

    We evaluated a rapid antigen-capture assay (VecTest) for detection of West Nile virus in oropharyngeal and cloacal swabs, collected at necropsy from owls (N = 93) and raptors (N = 27). Sensitivity was 93.5%–95.2% for northern owl species but <42.9% for all other species. Specificity was 100% for owls and 85.7% for raptors. PMID:15663862

  18. Real-time PCR as a surveillance tool for the detection of Trichinella infection in muscle samples from wildlife.

    PubMed

    Cuttell, Leigh; Corley, Sean W; Gray, Christian P; Vanderlinde, Paul B; Jackson, Louise A; Traub, Rebecca J

    2012-09-10

    Trichinella nematodes are the causative agent of trichinellosis, a meat-borne zoonosis acquired by consuming undercooked, infected meat. Although most human infections are sourced from the domestic environment, the majority of Trichinella parasites circulate in the natural environment in carnivorous and scavenging wildlife. Surveillance using reliable and accurate diagnostic tools to detect Trichinella parasites in wildlife hosts is necessary to evaluate the prevalence and risk of transmission from wildlife to humans. Real-time PCR assays have previously been developed for the detection of European Trichinella species in commercial pork and wild fox muscle samples. We have expanded on the use of real-time PCR in Trichinella detection by developing an improved extraction method and SYBR green assay that detects all known Trichinella species in muscle samples from a greater variety of wildlife. We simulated low-level Trichinella infections in wild pig, fox, saltwater crocodile, wild cat and a native Australian marsupial using Trichinella pseudospiralis or Trichinella papuae ethanol-fixed larvae. Trichinella-specific primers targeted a conserved region of the small subunit of the ribosomal RNA and were tested for specificity against host and other parasite genomic DNAs. The analytical sensitivity of the assay was at least 100 fg using pure genomic T. pseudospiralis DNA serially diluted in water. The diagnostic sensitivity of the assay was evaluated by spiking 10 g of each host muscle with T. pseudospiralis or T. papuae larvae at representative infections of 1.0, 0.5 and 0.1 larvae per gram, and shown to detect larvae at the lowest infection rate. A field sample evaluation on naturally infected muscle samples of wild pigs and Tasmanian devils showed complete agreement with the EU reference artificial digestion method (k-value=1.00). Positive amplification of mouse tissue experimentally infected with T. spiralis indicated the assay could also be used on encapsulated species in situ. This real-time PCR assay offers an alternative highly specific and sensitive diagnostic method for use in Trichinella wildlife surveillance and could be adapted to wildlife hosts of any region. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Laboratory Evaluation of the Alere q Point-of-Care System for Early Infant HIV Diagnosis.

    PubMed

    Hsiao, Nei-yuan; Dunning, Lorna; Kroon, Max; Myer, Landon

    2016-01-01

    Early infant diagnosis (EID) and prompt linkage to care are critical to minimise the high morbidity and mortality associated with infant HIV infection. Attrition in the "EID cascade" is common; however, point-of-care (POC) EID assays with same-day result could facilitate prompt linkage of HIV-infected infant to treatment. Despite a number of POC EID assays in development, few have been independently evaluated and data on new technologies are urgently needed to inform policy. We compared Alere q 1/2 Detect POC system laboratory test characteristics with the local standard of care (SOC), Roche CAP/CTM HIV-1 qualitative PCR in an independent laboratory-based evaluation in Cape Town, South Africa. Routinely EID samples collected between November 2013 and September 2014 were each tested by both SOC and POC systems. Repeat testing was done to troubleshoot any discrepancy between POC and SOC results. Overall, 1098 children with a median age of 47 days (IQR, 42-117) were included. Birth PCR (age <7 days) comprised of 8% (n = 92) tests while 56% (n = 620) of children tested as part of routine EID (ages 6-14 weeks). In the overall direct comparison, Alere q Detect achieved sensitivity of 95.5% (95% CI, 91.7-97.9%) and a specificity of 99.8% (95% CI, 99.1-100%). Following repeat testing of discordant samples and exclusion of any inconclusive results, the POC assay sensitivity and specificity were 96.9% (95% CI 93.4-98.9%) and 100% (lower 95% CI 98%) respectively. Among birth PCR tests the POC assay had slightly lower sensitivity (93.3% vs 96.5% in routine EID) and higher assay error rate (10% vs 5% in samples of older children, p = 0.04). Our results indicate this POC assay performs well for EID in the laboratory. The high specificity and thus high positive predictive value would suggest a positive POC result may be adequate for immediate infant ART initiation. While POC testing for EID may have particular utility for birth testing at delivery facilities, the lower sensitivity and error rate requires further attention, as does field implementation of POC EID technologies in other clinical care settings.

  20. Validation of the World Health Organization Enzyme-Linked Immunosorbent Assay for the Quantitation of Immunoglobulin G Serotype-Specific Anti-Pneumococcal Antibodies in Human Serum

    PubMed Central

    2017-01-01

    The World Health Organization (WHO) enzyme-linked immunosorbent assay (ELISA) guideline is currently accepted as the gold standard for the evaluation of immunoglobulin G (IgG) antibodies specific to pneumococcal capsular polysaccharide. We conducted validation of the WHO ELISA for 7 pneumococcal serotypes (4, 6B, 9V, 14, 18C, 19F, and 23F) by evaluating its specificity, precision (reproducibility and intermediate precision), accuracy, spiking recovery test, lower limit of quantification (LLOQ), and stability at the Ewha Center for Vaccine Evaluation and Study, Seoul, Korea. We found that the specificity, reproducibility, and intermediate precision were within acceptance ranges (reproducibility, coefficient of variability [CV] ≤ 15%; intermediate precision, CV ≤ 20%) for all serotypes. Comparisons between the provisional assignments of calibration sera and the results from this laboratory showed a high correlation > 94% for all 7 serotypes, supporting the accuracy of the ELISA. The spiking recovery test also fell within an acceptable range. The quantification limit, calculated using the LLOQ, for each of the serotypes was 0.05–0.093 μg/mL. The freeze-thaw stability and the short-term temperature stability were also within an acceptable range. In conclusion, we showed good performance using the standardized WHO ELISA for the evaluation of serotype-specific anti-pneumococcal IgG antibodies; the WHO ELISA can evaluate the immune response against pneumococcal vaccines with consistency and accuracy. PMID:28875600

  1. Validation of the World Health Organization Enzyme-Linked Immunosorbent Assay for the Quantitation of Immunoglobulin G Serotype-Specific Anti-Pneumococcal Antibodies in Human Serum.

    PubMed

    Lee, Hyunju; Lim, Soo Young; Kim, Kyung Hyo

    2017-10-01

    The World Health Organization (WHO) enzyme-linked immunosorbent assay (ELISA) guideline is currently accepted as the gold standard for the evaluation of immunoglobulin G (IgG) antibodies specific to pneumococcal capsular polysaccharide. We conducted validation of the WHO ELISA for 7 pneumococcal serotypes (4, 6B, 9V, 14, 18C, 19F, and 23F) by evaluating its specificity, precision (reproducibility and intermediate precision), accuracy, spiking recovery test, lower limit of quantification (LLOQ), and stability at the Ewha Center for Vaccine Evaluation and Study, Seoul, Korea. We found that the specificity, reproducibility, and intermediate precision were within acceptance ranges (reproducibility, coefficient of variability [CV] ≤ 15%; intermediate precision, CV ≤ 20%) for all serotypes. Comparisons between the provisional assignments of calibration sera and the results from this laboratory showed a high correlation > 94% for all 7 serotypes, supporting the accuracy of the ELISA. The spiking recovery test also fell within an acceptable range. The quantification limit, calculated using the LLOQ, for each of the serotypes was 0.05-0.093 μg/mL. The freeze-thaw stability and the short-term temperature stability were also within an acceptable range. In conclusion, we showed good performance using the standardized WHO ELISA for the evaluation of serotype-specific anti-pneumococcal IgG antibodies; the WHO ELISA can evaluate the immune response against pneumococcal vaccines with consistency and accuracy. © 2017 The Korean Academy of Medical Sciences.

  2. Rapid detection of Enterovirus and Coxsackievirus A10 by a TaqMan based duplex one-step real time RT-PCR assay.

    PubMed

    Chen, Jingfang; Zhang, Rusheng; Ou, Xinhua; Yao, Dong; Huang, Zheng; Li, Linzhi; Sun, Biancheng

    2017-06-01

    A TaqMan based duplex one-step real time RT-PCR (rRT-PCR) assay was developed for the rapid detection of Coxsackievirus A10 (CV-A10) and other enterovirus (EVs) in clinical samples. The assay was fully evaluated and found to be specific and sensitive. When applied in 115 clinical samples, a 100% diagnostic sensitivity in CV-A10 detection and 97.4% diagnostic sensitivity in other EVs were found. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Detection and Tracking of NY-ESO-1-Specific CD8+ T Cells by High-Throughput T Cell Receptor β (TCRB) Gene Rearrangements Sequencing in a Peptide-Vaccinated Patient.

    PubMed

    Miyai, Manami; Eikawa, Shingo; Hosoi, Akihiro; Iino, Tamaki; Matsushita, Hirokazu; Isobe, Midori; Uenaka, Akiko; Udono, Heiichiro; Nakajima, Jun; Nakayama, Eiichi; Kakimi, Kazuhiro

    2015-01-01

    Comprehensive immunological evaluation is crucial for monitoring patients undergoing antigen-specific cancer immunotherapy. The identification and quantification of T cell responses is most important for the further development of such therapies. Using well-characterized clinical samples from a high responder patient (TK-f01) in an NY-ESO-1f peptide vaccine study, we performed high-throughput T cell receptor β-chain (TCRB) gene next generation sequencing (NGS) to monitor the frequency of NY-ESO-1-specific CD8+ T cells. We compared these results with those of conventional immunological assays, such as IFN-γ capture, tetramer binding and limiting dilution clonality assays. We sequenced human TCRB complementarity-determining region 3 (CDR3) rearrangements of two NY-ESO-1f-specific CD8+ T cell clones, 6-8L and 2F6, as well as PBMCs over the course of peptide vaccination. Clone 6-8L possessed the TCRB CDR3 gene TCRBV11-03*01 and BJ02-01*01 with amino acid sequence CASSLRGNEQFF, whereas 2F6 possessed TCRBV05-08*01 and BJ02-04*01 (CASSLVGTNIQYF). Using these two sequences as models, we evaluated the frequency of NY-ESO-1-specific CD8+ T cells in PBMCs ex vivo. The 6-8L CDR3 sequence was the second most frequent in PBMC and was present at high frequency (0.7133%) even prior to vaccination, and sustained over the course of vaccination. Despite a marked expansion of NY-ESO-1-specific CD8+ T cells detected from the first through 6th vaccination by tetramer staining and IFN-γ capture assays, as evaluated by CDR3 sequencing the frequency did not increase with increasing rounds of peptide vaccination. By clonal analysis using 12 day in vitro stimulation, the frequency of B*52:01-restricted NY-ESO-1f peptide-specific CD8+ T cells in PBMCs was estimated as only 0.0023%, far below the 0.7133% by NGS sequencing. Thus, assays requiring in vitro stimulation might be underestimating the frequency of clones with lower proliferation potential. High-throughput TCRB sequencing using NGS can potentially better estimate the actual frequency of antigen-specific T cells and thus provide more accurate patient monitoring.

  4. Detection and Tracking of NY-ESO-1-Specific CD8+ T Cells by High-Throughput T Cell Receptor β (TCRB) Gene Rearrangements Sequencing in a Peptide-Vaccinated Patient

    PubMed Central

    Miyai, Manami; Eikawa, Shingo; Hosoi, Akihiro; Iino, Tamaki; Matsushita, Hirokazu; Isobe, Midori; Uenaka, Akiko; Udono, Heiichiro; Nakajima, Jun; Nakayama, Eiichi; Kakimi, Kazuhiro

    2015-01-01

    Comprehensive immunological evaluation is crucial for monitoring patients undergoing antigen-specific cancer immunotherapy. The identification and quantification of T cell responses is most important for the further development of such therapies. Using well-characterized clinical samples from a high responder patient (TK-f01) in an NY-ESO-1f peptide vaccine study, we performed high-throughput T cell receptor β-chain (TCRB) gene next generation sequencing (NGS) to monitor the frequency of NY-ESO-1-specific CD8+ T cells. We compared these results with those of conventional immunological assays, such as IFN-γ capture, tetramer binding and limiting dilution clonality assays. We sequenced human TCRB complementarity-determining region 3 (CDR3) rearrangements of two NY-ESO-1f-specific CD8+ T cell clones, 6-8L and 2F6, as well as PBMCs over the course of peptide vaccination. Clone 6-8L possessed the TCRB CDR3 gene TCRBV11-03*01 and BJ02-01*01 with amino acid sequence CASSLRGNEQFF, whereas 2F6 possessed TCRBV05-08*01 and BJ02-04*01 (CASSLVGTNIQYF). Using these two sequences as models, we evaluated the frequency of NY-ESO-1-specific CD8+ T cells in PBMCs ex vivo. The 6-8L CDR3 sequence was the second most frequent in PBMC and was present at high frequency (0.7133%) even prior to vaccination, and sustained over the course of vaccination. Despite a marked expansion of NY-ESO-1-specific CD8+ T cells detected from the first through 6th vaccination by tetramer staining and IFN-γ capture assays, as evaluated by CDR3 sequencing the frequency did not increase with increasing rounds of peptide vaccination. By clonal analysis using 12 day in vitro stimulation, the frequency of B*52:01-restricted NY-ESO-1f peptide-specific CD8+ T cells in PBMCs was estimated as only 0.0023%, far below the 0.7133% by NGS sequencing. Thus, assays requiring in vitro stimulation might be underestimating the frequency of clones with lower proliferation potential. High-throughput TCRB sequencing using NGS can potentially better estimate the actual frequency of antigen-specific T cells and thus provide more accurate patient monitoring. PMID:26291626

  5. Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute Scrub Typhus infection.

    PubMed

    Paris, Daniel H; Blacksell, Stuart D; Nawtaisong, Pruksa; Jenjaroen, Kemajittra; Teeraratkul, Achara; Chierakul, Wirongrong; Wuthiekanun, Vanaporn; Kantipong, Pacharee; Day, Nicholas P J

    2011-09-01

    There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy. In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following 'scrub typhus infection criteria' (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the 'gold standard' indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96-99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%. The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.

  6. Cloning and expression of an envelope gene of West Nile virus and evaluation of the protein for use in an IgM ELISA.

    PubMed

    Saxena, Divyasha; Parida, Manmohan; Rao, Putcha Venkata L; Kumar, Jyoti S

    2013-04-01

    West Nile virus (WNV) is a neurotropic flavivirus that has emerged globally as a significant cause of viral encephalitis. The early confirmatory diagnosis of WNV infections is important for timely clinical management and epidemiologic control in areas where multiple flaviviruses are endemic. The coexistence of WNV along with other members of flaviviruses like dengue and Japanese encephalitis in India has complicated the serodiagnosis due to cross-reactive antigens. In the present study, the development and evaluation of a highly sensitive and specific IgM enzyme-linked immunosorbent assay (ELISA) using the recombinant envelope protein (rWNV-Env) for rapid, early, and accurate diagnosis of WNV are reported. The gene coding for the envelope protein of WNV was cloned and expressed in pET 28a vector followed by purification of recombinant protein by affinity chromatography. An indirect IgM microplate ELISA using purified rWNV-Env protein was optimized having no cross reactivity with healthy human serum. Furthermore, the specificity of this assay was confirmed by cross checking with serum samples obtained from patients with dengue and Japanese encephalitis viruses. The comparative evaluation of this rWNV-Env protein-specific IgM ELISA with plaque reduction neutralization test assay using 105 acute phase of clinical samples revealed 95% concordance with sensitivity and specificity of 92% and 97%, respectively. The positive and negative predictive values of recombinant-based Env ELISA were 94% and 96%, respectively. The recombinant envelope protein-based WNV-specific ELISA reported in this study will be useful for rapid screening of large numbers of clinical samples in endemic areas during outbreaks. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Validity and reproducibility of measurement of islet autoreactivity by T-cell assays in subjects with early type 1 diabetes.

    PubMed

    Herold, Kevan C; Brooks-Worrell, Barbara; Palmer, Jerry; Dosch, H Michael; Peakman, Mark; Gottlieb, Peter; Reijonen, Helena; Arif, Sefina; Spain, Lisa M; Thompson, Clinton; Lachin, John M

    2009-11-01

    Type 1 diabetes results from an immunemediated destruction of beta-cells, likely to be mediated by T lymphocytes, but the sensitivity, specificity, and other measures of validity of existing assays for islet autoreactive T-cells are not well established. Such assays are vital for monitoring responses to interventions that may modulate disease progression. We studied the ability of cellular assays to discriminate responses in patients with type 1 diabetes and normal control subjects in a randomized blinded study in the U.S. and U.K. We evaluated the reproducibility of these measurements overall and to individual analytes from repeat collections. Responses in the cellular immunoblot, U.K.-ELISPOT, and T-cell proliferation assays could differentiate patients from control subjects with odds ratios of 21.7, 3.44, and 3.36, respectively, with sensitivity and specificity as high as 74 and 88%. The class II tetramer and U.S. ELISPOT assays performed less well. Despite the significant association of the responses with type 1 diabetes, the reproducibility of the measured responses, both overall and individual analytes, was relatively low. Positive samples from normal control subjects (i.e., false positives) were generally isolated to single assays. The cellular immunoblot, U.K.-ELISPOT, and T-cell proliferation assays can distinguish responses from patients with type 1 diabetes and healthy control subjects. The limited reproducibility of the measurements overall and of responses to individual analytes may reflect the difficulty in detection of low frequency of antigen-specific T-cells or variability in their appearance in peripheral blood.

  8. Prospective and Retrospective Evaluation of the Performance of the FDA-Approved Cepheid Xpert Flu/RSV XC Assay.

    PubMed

    Arbefeville, Sophie; Thonen-Kerr, Elizabeth; Ferrieri, Patricia

    2017-11-08

    Rapid and accurate detection of respiratory viruses is important in patient care and in guiding therapy and infection prevention policy. Rapid viral antigen assays are simple to perform and provide results within 15 to 30 minutes but are limited by their modest-to-moderate sensitivity. Molecular assays are more sensitive and specific but require more technical time and expertise and are more expensive. We verified the performance of the Xpert Flu/RSV XC assay prospectively, using patient respiratory samples from the 2014-2015 respiratory season, and, retrospectively, with frozen patient samples from the previous respiratory season. A total of 60 specimens were assayed on the Xpert Flu/RSV XC assay and by the GenMark Diagnostics eSensor Respiratory Viral Panel. The sensitivity of the Xpert Flu/RSV XC for Flu A was 100% (23/23), for Flu B, 80% (8/10), and for respiratory syncytial virus (RSV), 94.1% (16/17), compared to the reference assay (GenMark). The specificity was 100%. Eight specimens were positive for viruses other than Flu A/B or RSV, and this did not interfere with detection of targets in the Xpert assay. We demonstrated that the performance of the Xpert Flu/RSV XC was comparable to the more comprehensive molecular respiratory assay. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. A multiplex PCR assay for simultaneous detection of Escherichia coli O157:H7, Bacillus cereus, Vibrio parahaemolyticus, Salmonella spp., Listeria monocytogenes, and Staphylococcus aureus in Korean ready-to-eat food.

    PubMed

    Lee, Nari; Kwon, Kyung Yoon; Oh, Su Kyung; Chang, Hyun-Joo; Chun, Hyang Sook; Choi, Sung-Wook

    2014-07-01

    A multiplex polymerase chain reaction (PCR) assay was developed for simultaneous detection of Escherichia coli O157:H7, Bacillus cereus, Vibrio parahaemolyticus, Salmonella spp., Listeria monocytogenes, and Staphylococcus aureus in various Korean ready-to-eat foods. The six specific primer pairs for multiplex PCR were selected based on the O157 antigen (rfbE) gene of E. coli O157:H7, the DNA gyrase subunit B (gyrB) gene of B. cereus, the toxin regulatory protein (toxR) gene of V. parahaemolyticus, the invasion protein A (invA) gene of Salmonella spp., the hemolysin (hly) gene of L. monocytogenes, and the thermonuclease (nuc) gene of S. aureus. The 16S rRNA gene was targeted as an internal control gene in the presence of bacterial DNA. The specificity and sensitivity assays for multiplex primer pairs were investigated by testing different strains. When this multiplex PCR assay was applied to evaluate the validity of detecting six foodborne pathogens in artificially inoculated several ready-to-eat food samples, the assay was able to specifically simultaneously detect as few as 1 colony-forming unit/mL of each pathogen after enrichment for 12 h. Their presence in naturally contaminated samples also indicates that the developed multiplex PCR assay is an effective and informative supplement for practical use.

  10. Rapid and Specific Method for Evaluating Streptomyces Competitive Dynamics in Complex Soil Communities

    USDA-ARS?s Scientific Manuscript database

    Quantifying target microbial populations in complex communities remains a barrier to studying species interactions in soil environments. Quantitative real-time PCR (qPCR) offers a rapid and specific means to assess populations of target microorganisms. SYBR Green and TaqMan-based qPCR assays were de...

  11. Analytical specificity and sensitivity of a real-time polymerase chain reaction assay for identification of bovine mastitis pathogens.

    PubMed

    Koskinen, M T; Holopainen, J; Pyörälä, S; Bredbacka, P; Pitkälä, A; Barkema, H W; Bexiga, R; Roberson, J; Sølverød, L; Piccinini, R; Kelton, D; Lehmusto, H; Niskala, S; Salmikivi, L

    2009-03-01

    Intramammary infection (IMI), also known as mastitis, is the most frequently occurring and economically the most important infectious disease in dairy cattle. This study provides a validation of the analytical specificity and sensitivity of a real-time PCR-based assay that identifies 11 major pathogen species or species groups responsible for IMI, and a gene coding for staphylococcal beta-lactamase production (penicillin resistance). Altogether, 643 culture isolates originating from clinical bovine mastitis, human, and companion animal samples were analyzed using the assay. The isolates represented 83 different species, groups, or families, and originated from 6 countries in Europe and North America. The analytical specificity and sensitivity of the assay was 100% in bacterial and beta-lactamase identification across all isolates originating from bovine mastitis (n = 454). When considering the entire culture collection (including also the isolates originating from human and companion animal samples), 4 Streptococcus pyogenes, 1 Streptococcus salivarius, and 1 Streptococcus sanguis strain of human origin were identified as Streptococcus uberis, and 3 Shigella spp. strains were identified as Escherichia coli, decreasing specificity to 99% in Strep. uberis and to 99.5% in E. coli. These false-positive results were confirmed by sequencing of the 16S rRNA gene. Specificity and sensitivity remained at 100% for all other bacterial targets across the entire culture collection. In conclusion, the real-time PCR assay shows excellent analytical accuracy and holds much promise for use in routine bovine IMI testing programs. This study provides the basis for evaluating the assay's diagnostic performance against the conventional bacterial culture method in clinical field trials using mastitis milk samples.

  12. The use of chemical and molecular microbial indicators for faecal source identification.

    PubMed

    Gilpin, B; James, T; Nourozi, F; Saunders, D; Scholes, P; Savill, M

    2003-01-01

    Identifying the source of faecal pollution is important to enable appropriate management of faecal pollution of water. We are developing and evaluating a combination of these microbial and chemical indicators better able to identify the source of faecal pollution. These assays make use of a combination of direct PCR, culturing, and colony hybridisation to identify source specific species of Bifidobacterium, Rhodococcus and Bacteroides. In conjunction with assays for (a) fluorescent whitening agents and (b) faecal sterols and stanols, these indicators were able to identify human derived faecal pollution in river water containing inputs from septic tanks, municipal oxidation ponds, farmed animals and feral animals. Differentiating amongst the animal sources was more difficult and will require development of molecular assays for organisms specific to each animal group.

  13. Direct Application of the INNO-LiPA Rif.TB Line-Probe Assay for Rapid Identification of Mycobacterium tuberculosis Complex Strains and Detection of Rifampin Resistance in 360 Smear-Positive Respiratory Specimens from an Area of High Incidence of Multidrug-Resistant Tuberculosis

    PubMed Central

    Viveiros, Miguel; Leandro, Clara; Rodrigues, Liliana; Almeida, Josefina; Bettencourt, Rosário; Couto, Isabel; Carrilho, Lurdes; Diogo, José; Fonseca, Ana; Lito, Luís; Lopes, João; Pacheco, Teresa; Pessanha, Mariana; Quirim, Judite; Sancho, Luísa; Salfinger, Max; Amaral, Leonard

    2005-01-01

    The INNO-LiPA Rif.TB assay for the identification of Mycobacterium tuberculosis complex strains and the detection of rifampin (RIF) resistance has been evaluated with 360 smear-positive respiratory specimens from an area of high incidence of multidrug-resistant tuberculosis (MDR-TB). The sensitivity when compared to conventional identification/culture methods was 82.2%, and the specificity was 66.7%; the sensitivity and specificity were 100.0% and 96.9%, respectively, for the detection of RIF resistance. This assay has the potential to provide rapid information that is essential for the effective management of MDR-TB. PMID:16145166

  14. Performance Evaluation of Protein Chip Assay for Rapid Diagnosis of Hepatitis C Virus Infection in Injection Drug Abusers.

    PubMed

    Dai, Zhiyan; Shu, Xin; Li, Gang; Xi, Weidong

    2018-04-01

    We evaluated the performance of a protein chip assay for the detection of antibodies to hepatitis C virus (HCV) peptides among injection drug abusers (IDAs) by comparing the assay with existing methods, including enzyme-linked immunosorbent assay (ELISA), reverse transcription-polymerase chain reaction (RT-PCR), and recombinant immunoblot assay (RIBA). Seventy serum samples collected from IDAs were analyzed by protein chip assay. ELISA, RT-PCR, and RIBA assay were used to validate the results. The protein chips could detect different peptides' antibodies against HCV-C, HCV-NS3, HCV-NS4, HCV-NS5, and HCV-mix antigen; no cross reactivity between antigens was observed. Results of the protein-chip assay were compared with those of ELISA. Any inconsistency in results was validated by both RT-PCR and RIBA. Concordance between the results of the protein-chip assay and ELISA was 96.3% for positive samples and 100% for negative samples. The protein chip had a higher specificity than ELISA, a higher sensitivity than RTPCR, and similar specificity and sensitivity as compared to RIBA. The limit of detection of HCV antibodies in the protein chip assay was examined and calculated by incubation of model array with different dilutions. The protein chip assay required smaller amounts of both samples and reagents; it detected serum antibody in sample quantity as low as 3 ng/mL and at antibody dilution as low as 1:1000; its cost was low as well. The positive rates in the antiC, anti-NS3, anti-NS4, and anti-NS5 groups were significantly associated with levels of HCV RNA and the viral load. The HCV RNA and protein chip positive rate in the injection equipment-sharing group was higher than that in the non-injection equipment-sharing group. The protein chip assay is a faster and simpler approach to simultaneously screen for all HCV peptide antibodies accurately and to provide a rapid diagnosis of HCV infection in IDAs. The dominant positive HCV peptide antibodies were significantly associated with HCV RNA load, especially in the injection equipment-sharing group.

  15. A sensitive one-step TaqMan amplification approach for detection of rubella virus clade I and II genotypes in clinical samples.

    PubMed

    Claus, C; Bergs, S; Emmrich, N C; Hübschen, J M; Mankertz, A; Liebert, U G

    2017-02-01

    Although teratogenic rubella virus (RV) causes a vaccine-preventable disease, it is still endemic in several countries worldwide. Thus, there is a constant risk of RV importation into non-endemic areas. RV monitoring, especially during measles and Zika virus outbreaks, requires reliable diagnostic tools. For this study, a TaqMan-based one-step reverse transcription-quantitative PCR (RT-qPCR) assay, with the p90 gene as a novel and so far unexplored target for detection of clade I and II genotypes, was developed and evaluated. Automated nucleic acid extraction was carried out. Performance characteristics of the TaqMan RT-qPCR assay were determined for a RV plasmid standard and RNA extracted from virus-infected cell culture supernatants representing clade I and II genotypes. Diagnostic specificity and sensitivity were validated against other RNA and DNA viruses, relevant for RV diagnostic approaches and for RV-positive clinical samples, respectively. The assay is specific and highly sensitive with a limit of detection as low as five to one copies per reaction or 200 infectious virus particles per ml. The coefficients of variation (CV) were specified as intra- (within one run) and inter- (between different runs) assay variation, and calculated based on the standard deviations for the obtained Ct values of the respective samples. Intra- and inter-assay CV values were low, with a maximum of 3.4% and 2.4%, respectively. The assay was shown to be suitable and specific for the analysis of clinical samples. With p90 as a novel target, the highly sensitive and specific TaqMan assay outlined in this study is suitable for RV diagnosis worldwide.

  16. Generation and characterization of a unique reagent that recognizes a panel of recombinant human monoclonal antibody therapeutics in the presence of endogenous human IgG.

    PubMed

    Wang, Xiangdan; Quarmby, Valerie; Ng, Carl; Chuntharapai, Anan; Shek, Theresa; Eigenbrot, Charles; Kelley, Robert F; Shia, Steven; McCutcheon, Krista; Lowe, John; Leddy, Cecilia; Coachman, Kyle; Cain, Gary; Chu, Felix; Hotzel, Isidro; Maia, Mauricio; Wakshull, Eric; Yang, Jihong

    2013-01-01

    Pharmacokinetic (PK) and immunohistochemistry (IHC) assays are essential to the evaluation of the safety and efficacy of therapeutic monoclonal antibodies (mAb) during drug development. These methods require reagents with a high degree of specificity because low concentrations of therapeutic antibody need to be detected in samples containing high concentrations of endogenous human immunoglobulins. Current assay reagent generation practices are labor-intensive and time-consuming. Moreover, these practices are molecule-specific and so only support one assay for one program at a time. Here, we describe a strategy to generate a unique assay reagent, 10C4, that preferentially recognizes a panel of recombinant human mAbs over endogenous human immunoglobulins. This "panel-specific" feature enables the reagent to be used in PK and IHC assays for multiple structurally-related therapeutic mAbs. Characterization revealed that the 10C4 epitope is conformational, extensive and mainly composed of non-CDR residues. Most key contact residues were conserved among structurally-related therapeutic mAbs, but the combination of these residues exists at low prevalence in endogenous human immunoglobulins. Interestingly, an indirect contact residue on the heavy chain of the therapeutic appears to play a critical role in determining whether or not it can bind to 10C4, but has no affect on target binding. This may allow us to improve the binding of therapeutic mAbs to 10C4 for assay development in the future. Here, for the first time, we present a strategy to develop a panel-specific reagent that can expedite the development of multiple clinical assays for structurally-related therapeutic mAbs.

  17. Development of duplex real-time PCR for the detection of WSSV and PstDV1 in cultivated shrimp.

    PubMed

    Leal, Carlos A G; Carvalho, Alex F; Leite, Rômulo C; Figueiredo, Henrique C P

    2014-07-05

    The White spot syndrome virus (WSSV) and Penaeus stylirostris penstyldensovirus 1 (previously named Infectious hypodermal and hematopoietic necrosis virus-IHHNV) are two of the most important viral pathogens of penaeid shrimp. Different methods have been applied for diagnosis of these viruses, including Real-time PCR (qPCR) assays. A duplex qPCR method allows the simultaneous detection of two viruses in the same sample, which is more cost-effective than assaying for each virus separately. Currently, an assay for the simultaneous detection of the WSSV and the PstDV1 in shrimp is unavailable. The aim of this study was to develop and standardize a duplex qPCR assay for the simultaneous detection of the WSSV and the PstDV1 in clinical samples of diseased L. vannamei. In addition, to evaluate the performance of two qPCR master mixes with regard to the clinical sensitivity of the qPCR assay, as well as, different methods for qPCR results evaluation. The duplex qPCR assay for detecting WSSV and PstDV1 in clinical samples was successfully standardized. No difference in the amplification of the standard curves was observed between the duplex and singleplex assays. Specificities and sensitivities similar to those of the singleplex assays were obtained using the optimized duplex qPCR. The analytical sensitivities of duplex qPCR were two copies of WSSV control plasmid and 20 copies of PstDV1 control plasmid. The standardized duplex qPCR confirmed the presence of viral DNA in 28 from 43 samples tested. There was no difference for WSSV detection using the two kits and the distinct methods for qPCR results evaluation. High clinical sensitivity for PstDV1 was obtained with TaqMan Universal Master Mix associated with relative threshold evaluation. Three cases of simultaneous infection by the WSSV and the PstDV1 were identified with duplex qPCR. The standardized duplex qPCR was shown to be a robust, highly sensitive, and feasible diagnostic tool for the simultaneous detection of the WSSV and the PstDV1 in whiteleg shrimp. The use of the TaqMan Universal Master Mix and the relative threshold method of data analysis in our duplex qPCR method provided optimal levels of sensitivity and specificity.

  18. Real-time reverse transcription-polymerase chain reaction assays for identification of wild poliovirus 1 & 3.

    PubMed

    Sharma, Deepa K; Nalavade, Uma P; Deshpande, Jagadish M

    2015-10-01

    The poliovirus serotype identification and intratypic differentiation by real-time reverse transcription-polymerase chain reaction (rRT-PCR) assay is suitable for serotype mixtures but not for intratypic mixtures of wild and vaccine poliovirus strains. This study was undertaken to develop wild poliovirus 1 and 3 (WPV1 and WPV3) specific rRT-PCR assays for use. Specific primers and probes for rRT-PCR were designed based on VP1 sequences of WPV1 and WPV3 isolated in India since 2000. The specificity of the rRT-PCR assays was evaluated using WPV1 and WPV3 of different genetic lineages, non-polio enteroviruses (NPEVs) and mixtures of wild/wild and wild/Sabin vaccine strains. The sensitivity of the assays was determined by testing serial 10-fold dilutions of wild poliovirus 1 and 3 stock suspensions of known titre. No cross-reactivity with Sabin strains, intertypic wild poliovirus isolates or 27 types of NPEVs across all the four Enterovirus species was found for both the wild poliovirus 1 and 3 rRT-PCR assays. All WPV1 and WPV3 strains isolated since 2000 were successfully amplified. The rRT-PCR assays detected 10 4.40 CCID 50 /ml of WPV1 and 10 4.00 CCID 50 /ml of WPV3, respectively either as single isolate or mixture with Sabin vaccine strains or intertypic wild poliovirus. rRT-PCR assays for WPV1 and WPV3 have been validated to detect all the genetic variations of the WPV1 and WPV3 isolated in India for the last decade. When used in combination with the current rRT-PCR assay testing was complete for confirmation of the presence of wild poliovirus in intratypic mixtures.

  19. High-Throughput Genotyping of Single Nucleotide Polymorphisms in the Plasmodium falciparum dhfr Gene by Asymmetric PCR and Melt-Curve Analysis▿

    PubMed Central

    Cruz, Rochelle E.; Shokoples, Sandra E.; Manage, Dammika P.; Yanow, Stephanie K.

    2010-01-01

    Mutations within the Plasmodium falciparum dihydrofolate reductase gene (Pfdhfr) contribute to resistance to antimalarials such as sulfadoxine-pyrimethamine (SP). Of particular importance are the single nucleotide polymorphisms (SNPs) within codons 51, 59, 108, and 164 in the Pfdhfr gene that are associated with SP treatment failure. Given that traditional genotyping methods are time-consuming and laborious, we developed an assay that provides the rapid, high-throughput analysis of parasite DNA isolated from clinical samples. This assay is based on asymmetric real-time PCR and melt-curve analysis (MCA) performed on the LightCycler platform. Unlabeled probes specific to each SNP are included in the reaction mixture and hybridize differentially to the mutant and wild-type sequences within the amplicon, generating distinct melting curves. Since the probe is present throughout PCR and MCA, the assay proceeds seamlessly with no further addition of reagents. This assay was validated for analytical sensitivity and specificity using plasmids, purified genomic DNA from reference strains, and parasite cultures. For all four SNPs, correct genotypes were identified with 100 copies of the template. The performance of the assay was evaluated with a blind panel of clinical isolates from travelers with low-level parasitemia. The concordance between our assay and DNA sequencing ranged from 84 to 100% depending on the SNP. We also directly compared our MCA assay to a published TaqMan real-time PCR assay and identified major issues with the specificity of the TaqMan probes. Our assay provides a number of technical improvements that facilitate the high-throughput screening of patient samples to identify SP-resistant malaria. PMID:20631115

  20. Key learnings from performance of the U.S. EPA Endocrine Disruptor Screening Program (EDSP) Tier 1 in vitro assays.

    PubMed

    LeBaron, Matthew J; Coady, Katie K; O'Connor, John C; Nabb, Diane L; Markell, Lauren K; Snajdr, Suzanne; Sue Marty, M

    2014-02-01

    Tier 1 of the U.S. EPA Endocrine Disruptor Screening Program comprises 11 studies: five in vitro assays, four in vivo mammalian assays, and two in vivo nonmammalian assays. The battery is designed to detect compounds with the potential to interact with the estrogen, androgen, or thyroid signaling pathways. This article examines the procedures, results, and data interpretation for the five Tier 1 in vitro assays: estrogen receptor (ER) and androgen receptor binding assays, an ER transactivation assay, an aromatase assay, and a steroidogenesis assay. Data are presented from two laboratories that have evaluated approximately 11 compounds in the Tier 1 in vitro assays. Generally, the ER and androgen receptor binding assays and the aromatase assay showed good specificity and reproducibility. As described in the guideline for the ER transactivation assay, a result is considered positive when the test compound induces a reporter gene signal that reaches 10% of the response seen with 1 nM 17β-estradiol (positive control). In the experience of these laboratories, this cutoff criterion may result in false-positive responses. For the steroidogenesis assay, there is variability in the basal and stimulated production of testosterone and estradiol by the H295R cells. This variability in responsiveness, coupled with potential cell stress at high concentrations of test compound, may make it difficult to discern whether hormone alterations are specific steroidogenesis alterations (i.e., endocrine active). Lastly, both laboratories had difficulty meeting some recommended performance criteria for each Tier 1 in vitro assay. Data with only minor deviations were deemed valid. © 2014 Wiley Periodicals, Inc.

  1. CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Assays: direct validation using reference samples from the CALIPER cohort.

    PubMed

    Estey, Mathew P; Cohen, Ashley H; Colantonio, David A; Chan, Man Khun; Marvasti, Tina Binesh; Randell, Edward; Delvin, Edgard; Cousineau, Jocelyne; Grey, Vijaylaxmi; Greenway, Donald; Meng, Qing H; Jung, Benjamin; Bhuiyan, Jalaluddin; Seccombe, David; Adeli, Khosrow

    2013-09-01

    The CALIPER program recently established a comprehensive database of age- and sex-stratified pediatric reference intervals for 40 biochemical markers. However, this database was only directly applicable for Abbott ARCHITECT assays. We therefore sought to expand the scope of this database to biochemical assays from other major manufacturers, allowing for a much wider application of the CALIPER database. Based on CLSI C28-A3 and EP9-A2 guidelines, CALIPER reference intervals were transferred (using specific statistical criteria) to assays performed on four other commonly used clinical chemistry platforms including Beckman Coulter DxC800, Ortho Vitros 5600, Roche Cobas 6000, and Siemens Vista 1500. The resulting reference intervals were subjected to a thorough validation using 100 reference specimens (healthy community children and adolescents) from the CALIPER bio-bank, and all testing centers participated in an external quality assessment (EQA) evaluation. In general, the transferred pediatric reference intervals were similar to those established in our previous study. However, assay-specific differences in reference limits were observed for many analytes, and in some instances were considerable. The results of the EQA evaluation generally mimicked the similarities and differences in reference limits among the five manufacturers' assays. In addition, the majority of transferred reference intervals were validated through the analysis of CALIPER reference samples. This study greatly extends the utility of the CALIPER reference interval database which is now directly applicable for assays performed on five major analytical platforms in clinical use, and should permit the worldwide application of CALIPER pediatric reference intervals. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Preliminary Validation of Direct Detection of Foot-And-Mouth Disease Virus within Clinical Samples Using Reverse Transcription Loop-Mediated Isothermal Amplification Coupled with a Simple Lateral Flow Device for Detection

    PubMed Central

    Waters, Ryan A.; Fowler, Veronica L.; Armson, Bryony; Nelson, Noel; Gloster, John; Paton, David J.; King, Donald P.

    2014-01-01

    Rapid, field-based diagnostic assays are desirable tools for the control of foot-and-mouth disease (FMD). Current approaches involve either; 1) Detection of FMD virus (FMDV) with immuochromatographic antigen lateral flow devices (LFD), which have relatively low analytical sensitivity, or 2) portable RT-qPCR that has high analytical sensitivity but is expensive. Loop-mediated isothermal amplification (LAMP) may provide a platform upon which to develop field based assays without these drawbacks. The objective of this study was to modify an FMDV-specific reverse transcription–LAMP (RT-LAMP) assay to enable detection of dual-labelled LAMP products with an LFD, and to evaluate simple sample processing protocols without nucleic acid extraction. The limit of detection of this assay was demonstrated to be equivalent to that of a laboratory based real-time RT-qPCR assay and to have a 10,000 fold higher analytical sensitivity than the FMDV-specific antigen LFD currently used in the field. Importantly, this study demonstrated that FMDV RNA could be detected from epithelial suspensions without the need for prior RNA extraction, utilising a rudimentary heat source for amplification. Once optimised, this RT-LAMP-LFD protocol was able to detect multiple serotypes from field epithelial samples, in addition to detecting FMDV in the air surrounding infected cattle, pigs and sheep, including pre-clinical detection. This study describes the development and evaluation of an assay format, which may be used as a future basis for rapid and low cost detection of FMDV. In addition it provides providing “proof of concept” for the future use of LAMP assays to tackle other challenging diagnostic scenarios encompassing veterinary and human health. PMID:25165973

  3. Multiplex Detection of Rare Mutations by Picoliter Droplet Based Digital PCR: Sensitivity and Specificity Considerations.

    PubMed

    Zonta, Eleonora; Garlan, Fanny; Pécuchet, Nicolas; Perez-Toralla, Karla; Caen, Ouriel; Milbury, Coren; Didelot, Audrey; Fabre, Elizabeth; Blons, Hélène; Laurent-Puig, Pierre; Taly, Valérie

    2016-01-01

    In cancer research, the accuracy of the technology used for biomarkers detection is remarkably important. In this context, digital PCR represents a highly sensitive and reproducible method that could serve as an appropriate tool for tumor mutational status analysis. In particular, droplet-based digital PCR approaches have been developed for detection of tumor-specific mutated alleles within plasmatic circulating DNA. Such an approach calls for the development and validation of a very significant quantity of assays, which can be extremely costly and time consuming. Herein, we evaluated assays for the detection and quantification of various mutations occurring in three genes often misregulated in cancers: the epidermal growth factor receptor (EGFR), the v-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog (KRAS) and the Tumoral Protein p53 (TP53) genes. In particular, commercial competitive allele-specific TaqMan® PCR (castPCR™) technology, as well as TaqMan® and ZEN™ assays, have been evaluated for EGFR p.L858R, p.T790M, p.L861Q point mutations and in-frame deletions Del19. Specificity and sensitivity have been determined on cell lines DNA, plasmatic circulating DNA of lung cancer patients or Horizon Diagnostics Reference Standards. To show the multiplexing capabilities of this technology, several multiplex panels for EGFR (several three- and four-plexes) have been developed, offering new "ready-to-use" tests for lung cancer patients.

  4. Development of a rapid and visual nucleotide detection method for a Chinese epidemic strain of Orientia tsutsugamushi based on recombinase polymerase amplification assay and lateral flow test.

    PubMed

    Qi, Yong; Yin, Qiong; Shao, Yinxiu; Cao, Min; Li, Suqin; Chen, Hongxia; Shen, Wanpeng; Rao, Jixian; Li, Jiameng; Li, Xiaoling; Sun, Yu; Lin, Yu; Deng, Yi; Zeng, Wenwen; Zheng, Shulong; Liu, Suyun; Li, Yuexi

    2018-05-01

    Orientia tsutsugamushi is an obligate intracellular pathogen that causes scrub typhus. Diagnosing scrub typhus remains a challenge, and a sensitive, specific, simple, and rapid diagnostic test is still needed. A recombinase polymerase amplification (RPA) assay combined with a lateral flow (LF) test targeting the 56-kDa gene of a Karp-like strain of O. tsutsugamushi was developed and optimized. The detection limits, sensitivity, specificity, and simulative clinical performance were evaluated. Primers and probe were screened to establish the RPA assay, and the reaction conditions were optimized. The detection limit was 10 copies/reaction in detecting plasmid DNA and 12 copies/reaction in detecting genomic DNA. The RPA-LF method could differentiate O. tsutsugamushi from other phylogenetically related bacteria. The sensitivity was 100% and specificity was over 90%, when evaluated using infected animal samples or simulative clinical samples. Furthermore, the method was completed in 20min at 37°C followed by a 3-5min incubation at room temperature for the development of an immunochromatographic strip, and the results could be determined visually. This method is promising for wide-ranging use in basic medical units considering that it requires minimal instruments and infrastructure and is highly time-efficient, sensitive, and specific for diagnosing scrub typhus. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Aspergillus Galactomannan Enzyme Immunoassay and Quantitative PCR for Diagnosis of Invasive Aspergillosis with Bronchoalveolar Lavage Fluid

    PubMed Central

    Musher, Benjamin; Fredricks, David; Leisenring, Wendy; Balajee, S. Arunmozhi; Smith, Caitlin; Marr, Kieren A.

    2004-01-01

    Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in hematopoietic stem cell transplant patients. Diagnosis requires microbiological or histopathologic demonstration of the organism in tissues; however, cultivation of Aspergillus species from respiratory secretions has low diagnostic sensitivity. Assays to detect Aspergillus antigen or DNA in bronchoalveolar lavage (BAL) fluid could facilitate earlier diagnosis, thereby guiding optimal therapy and obviating the need for additional costly and potentially morbid diagnostic evaluation. We evaluated the performance of a galactomannan enzyme immunoassay (GM EIA; Bio-Rad) by using a range of index cutoffs to define positivity and a quantitative PCR (qPCR) assay for the detection of Aspergillus species from BAL samples of patients with proven and probable IPA (case patients; n = 49) and without IPA (control patients; n = 50). The sensitivity of the GM EIA was 61% with an index cutoff of 1.0 and 76% with an index cutoff of 0.5; the corresponding specificities were 98 and 94%, respectively. The sensitivity and specificity of qPCR assay were 67 and 100%, respectively. The sensitivity with 22 culture-negative BAL specimens from patients with IPA was 41% for GM EIA with an index cutoff of 1.0, 59% for GM EIA with an index cutoff of 0.5, and 36% for qPCR assay. GM EIA indices and DNA quantities corresponded to BAL fungal burdens, with culture-positive samples having larger amounts of antigen and DNA compared to culture-negative samples. GM EIA and qPCR assay add to the sensitivity of BAL for diagnosing IPA in high-risk patients, with excellent specificity. Adjunctive use of these tests may reduce dependence on invasive diagnostic procedures. PMID:15583275

  6. Antibody Functional Assays as Measures of Fc Receptor-Mediated Immunity to HIV - New Technologies and their Impact on the HIV Vaccine Field.

    PubMed

    Wines, Bruce D; Billings, Hugh; Mclean, Milla R; Kent, Stephen J; Hogarth, P Mark

    2017-01-01

    There is now intense interest in the role of HIV-specific antibodies and the engagement of FcγR functions in the control and prevention of HIV infection. The analyses of the RV144 vaccine trial, natural progression cohorts, and macaque models all point to a role for Fc-dependent effector functions, such as cytotoxicity (ADCC) or phagocytosis (ADCP), in the control of HIV. However, reliable assays that can be reproducibly used across different laboratories to measure Fcdependent functions, such as antibody dependent cellular cytotoxicity (ADCC) are limited. This brief review highlights the importance of Fc properties for immunity to HIV, particularly via FcγR diversity and function. We discuss assays used to study FcR mediated functions of HIV-specific Ab, including our recently developed novel cell-free ELISA using homo-dimeric FcγR ectodomains to detect functionally relevant viral antigen-specific antibodies. The binding of these dimeric FcγR ectodomains, to closely spaced pairs of IgG Fc, mimics the engagement and cross-linking of Fc receptors by IgG opsonized virions or infected cells as the essential prerequisite to the induction of Ab-dependent effector functions. The dimeric FcγR ELISA reliably correlates with ADCC in patient responses to influenza. The assay is amenable to high throughput and could be standardized across laboratories. We propose the assay has broader implications for the evaluation of the quality of antibody responses in viral infections and for the rapid evaluation of responses in vaccine development campaigns for HIV and other viral infections. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Evaluation of the performance of two tuberculosis interferon gamma release assays (IGRA-ELISA and T-SPOT.TB) for diagnosing Mycobacterium tuberculosis infection.

    PubMed

    Wang, Linchuan; Tian, Xu-Dong; Yu, Yan; Chen, Wei

    2018-04-01

    The IGRA-ELISA and T-SPOT.TB are widely used in China. The aim of the study was to evaluate the performance of the two assays in diagnosis Mycobacterium tuberculosis infection. Of the 3727 patients in the study, 204 underwent testing using both the T-SPOT.TB and IGRA-ELISA, 1794 were tested using the T-SPOT.TB only, and 1729 were tested using the IGRA-ELISA only. The positive rate and consistency of the two assays were analyzed, and their sensitivity and specificity for diagnosing active tuberculosis were compared. There were no significant differences in the positive rate between the T-SPOT.TB test (25.8%) and IGRA-ELISA (28.6%), p = .065. The two assays were highly consistent, with a kappa value of 0.852 (p < .0001) and a total coincidence rate of 92.7%. For the diagnosis of active tuberculosis, the sensitivity and specificity values of the T-SPOT.TB test were 82.9% (107/129) and 78.6% (1309/1665), respectively, and those of IGRA-ELISA were 81.7% (94/115) and 75.2% (1214/1614), respectively. There were no significant differences in sensitivity (p > .05), but the specificity of the T-SPOT.TB test was slightly higher than that of IGRA-ELISA (p = .023). Both in terms of diagnosing M. tuberculosis infection and ruling out active tuberculosis, the performance of the IGRA-ELISA-a simple, almost labor-free assay that allows simultaneous processing of a very large number of samples-was well-matched with that of T-SPOT.TB test. However, IGRAs cannot be used as the only test to diagnose active tuberculosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Antibody Functional Assays as Measures of Fc Receptor-Mediated Immunity to HIV - New Technologies and their Impact on the HIV Vaccine Field

    PubMed Central

    Wines, Bruce D.; Billings, Hugh; Mclean, Milla R.; Kent, Stephen J.; Hogarth, P. Mark

    2017-01-01

    Background: There is now intense interest in the role of HIV-specific antibodies and the engagement of FcγR functions in the control and prevention of HIV infection. The analyses of the RV144 vaccine trial, natural progression cohorts, and macaque models all point to a role for Fc-dependent effector functions, such as cytotoxicity (ADCC) or phagocytosis (ADCP), in the control of HIV. However, reliable assays that can be reproducibly used across different laboratories to measure Fc-dependent functions, such as antibody dependent cellular cytotoxicity (ADCC) are limited. Method: This brief review highlights the importance of Fc properties for immunity to HIV, particular-ly via FcγR diversity and function. We discuss assays used to study FcR mediated functions of HIV-specific Ab, including our recently developed novel cell-free ELISA using homo-dimeric FcγR ecto-domains to detect functionally relevant viral antigen-specific antibodies. Results: The binding of these dimeric FcγR ectodomains, to closely spaced pairs of IgG Fc, mimics the engagement and cross-linking of Fc receptors by IgG opsonized virions or infected cells as the es-sential prerequisite to the induction of Ab-dependent effector functions. The dimeric FcγR ELISA reli-ably correlates with ADCC in patient responses to influenza. The assay is amenable to high throughput and could be standardized across laboratories. Conclusion: We propose the assay has broader implications for the evaluation of the quality of anti-body responses in viral infections and for the rapid evaluation of responses in vaccine development campaigns for HIV and other viral infections. PMID:28322167

  9. Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinsky, Benjamin A.; Sahoo, Malaya K.; Sandlund, Johanna

    The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Our study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay,more » the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. In conclusion, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection is critical.« less

  10. Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

    DOE PAGES

    Pinsky, Benjamin A.; Sahoo, Malaya K.; Sandlund, Johanna; ...

    2015-11-12

    The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Our study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay,more » the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. In conclusion, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection is critical.« less

  11. Development of an Immunochromatography Assay (QuickNavi-Ebola) to Detect Multiple Species of Ebolaviruses

    PubMed Central

    Yoshida, Reiko; Muramatsu, Shino; Akita, Hiroshi; Saito, Yuji; Kuwahara, Miwa; Kato, Daisuke; Changula, Katendi; Miyamoto, Hiroko; Kajihara, Masahiro; Manzoor, Rashid; Furuyama, Wakako; Marzi, Andrea; Feldmann, Heinz; Mweene, Aaron; Masumu, Justin; Kapeteshi, Jimmy; Muyembe-Tamfum, Jean-Jacques; Takada, Ayato

    2016-01-01

    The latest outbreak of Ebola virus disease (EVD) in West Africa has highlighted the urgent need for the development of rapid and reliable diagnostic assays. We used monoclonal antibodies specific to the ebolavirus nucleoprotein to develop an immunochromatography (IC) assay (QuickNavi-Ebola) for rapid diagnosis of EVD. The IC assay was first evaluated with tissue culture supernatants of infected Vero E6 cells and found to be capable of detecting 103–104 focus-forming units/mL of ebolaviruses. Using serum samples from experimentally infected nonhuman primates, we confirmed that the assay could detect the viral antigen shortly after disease onset. It was also noted that multiple species of ebolaviruses could be detected by the IC assay. Owing to the simplicity of the assay procedure and absence of requirements for special equipment and training, QuickNavi-Ebola is expected to be a useful tool for rapid diagnosis of EVD. PMID:27462094

  12. Evaluation of sensitivity and specificity of a standardized procedure using different reagents for the detection of lupus anticoagulants. The Working Group on Hemostasis of the Société Française de Biologie Clinique and for the Groupe d'Etudes sur I'Hémostase et la Thrombose.

    PubMed

    Goudemand, J; Caron, C; De Prost, D; Derlon, A; Borg, J Y; Sampol, J; Sié, P

    1997-02-01

    This study was designed to test the sensitivity and specificity of a combination of 3 phospholipid-dependent assays performed with various reagents, for the detection of lupus anticoagulant (LA). Plasmas containing an LA (n = 56) or displaying various confounding pathologies [58 intrinsic pathway factor deficiencies, 9 factor VIII inhibitors, 28 plasmas from patients treated with an oral anticoagulant (OAC)] were selected. In a first step, the efficiency of each assay and reagent was assessed using the Receiving Operating Characteristic (ROC) method. Optimal cut-offs providing both sensitivity and specificity > or = 80% were determined. The APTT assay and most of the phospholipid neutralization assays failed to discriminate factor VIII inhibitors from LA. In a second step, using the optimal cut-offs determined above, the results of all the possible combinations of the 3 assays performed with 4 different reagents were analyzed. Thirteen combinations of reagents allowed > or = 80% of plasmas of each category (LA, factor deficiency or OAC) to be correctly classified (3/3 positive test results in LA-containing plasmas and 0/3 positive results in LA-negative samples).

  13. Diagnostic utility of a line probe assay for multidrug resistant-TB in smear-negative pulmonary tuberculosis.

    PubMed

    Singh, Binit Kumar; Sharma, Surendra K; Sharma, Rohini; Sreenivas, Vishnubhatla; Myneedu, Vithal P; Kohli, Mikashmi; Bhasin, Dinkar; Sarin, Sanjay

    2017-01-01

    To evaluate the performance of Genotype MTBDRplus VER 2.0 in the diagnosis of Mycobacterium tuberculosis (MTB) in sputum smear-negative pulmonary TB cases. A total of 572 Ziehl-Neelsen sputum smear-negative samples were selected and subjected to line probe assay (Genotype MTBDRplus VER 2.0), and culture in mycobacterial growth indicator tube (MGIT-960). Immunochromatographic test was used to confirm the MTB-complex (MTBC) in culture-positive samples and phenotypic drug-susceptibility testing was done using MGIT-960. The line probe assay was able to diagnose MTBC in 38.2% (213/558) of specimens after excluding 14 nontuberculous mycobacteria. Sensitivity and specificity of the assay were 68.4% and 89.3% respectively, considering MGIT-960 culture as gold standard after excluding contaminated and invalid results. On comparing with composite reference standard, the assay had 71.5% sensitivity and 100% specificity in the diagnosis of tuberculosis. The sensitivity and specificity for detecting resistance to rifampicin (RMP) were 100% and 99.24% respectively and for resistance to isoniazid (INH) were 97.62% and 98.55%, respectively. Genotype MTBDRplus VER 2.0 is a rapid and precise diagnostic tool for detection of MTB in sputum smear-negative samples. It also facilitates accurate diagnosis of RMP and INH resistance within turn around-time.

  14. Development of two real-time polymerase chain reaction assays to detect Actinobacillus pleuropneumoniae serovars 1-9-11 and serovar 2.

    PubMed

    Marois-Créhan, Corinne; Lacouture, Sonia; Jacques, Mario; Fittipaldi, Nahuel; Kobisch, Marylène; Gottschalk, Marcelo

    2014-01-01

    Two real-time, or quantitative, polymerase chain reaction (qPCR) assays were developed to detect Actinobacillus pleuropneumoniae serovars 1-9-11 (highly related serovars with similar virulence potential) and serovar 2, respectively. The specificity of these assays was verified on a collection of 294 strains, which included all 16 reference A. pleuropneumoniae strains (including serovars 5a and 5b), 263 A. pleuropneumoniae field strains isolated between 1992 and 2009 in different countries, and 15 bacterial strains other than A. pleuropneumoniae. The detection levels of both qPCR tests were evaluated using 10-fold dilutions of chromosomal DNA from reference strains of A. pleuropneumoniae serovars 1 and 2, and the detection limit for both assays was 50 fg per assay. The analytical sensitivities of the qPCR tests were also estimated by using pure cultures and tonsils experimentally spiked with A. pleuropneumoniae. The detection threshold was 2.5 × 10(4) colony forming units (CFU)/ml and 2.9 × 10(5) CFU/0.1 g of tonsil, respectively, for both assays. These specific and sensitive tests can be used for the serotyping of A. pleuropneumoniae in diagnostic laboratories to control porcine pleuropneumonia.

  15. A Melting Curve-Based Multiplex RT-qPCR Assay for Simultaneous Detection of Four Human Coronaviruses

    PubMed Central

    Wan, Zhenzhou; Zhang, Ya’nan; He, Zhixiang; Liu, Jia; Lan, Ke; Hu, Yihong; Zhang, Chiyu

    2016-01-01

    Human coronaviruses HCoV-OC43, HCoV-229E, HCoV-NL63 and HCoV-HKU1 are common respiratory viruses associated with acute respiratory infection. They have a global distribution. Rapid and accurate diagnosis of HCoV infection is important for the management and treatment of hospitalized patients with HCoV infection. Here, we developed a melting curve-based multiplex RT-qPCR assay for simultaneous detection of the four HCoVs. In the assay, SYTO 9 was used to replace SYBR Green I as the fluorescent dye, and GC-modified primers were designed to improve the melting temperature (Tm) of the specific amplicon. The four HCoVs were clearly distinguished by characteristic melting peaks in melting curve analysis. The detection sensitivity of the assay was 3 × 102 copies for HCoV-OC43, and 3 × 101 copies for HCoV-NL63, HCoV-229E and HCoV-HKU1 per 30 μL reaction. Clinical evaluation and sequencing confirmation demonstrated that the assay was specific and reliable. The assay represents a sensitive and reliable method for diagnosis of HCoV infection in clinical samples. PMID:27886052

  16. A Melting Curve-Based Multiplex RT-qPCR Assay for Simultaneous Detection of Four Human Coronaviruses.

    PubMed

    Wan, Zhenzhou; Zhang, Ya'nan; He, Zhixiang; Liu, Jia; Lan, Ke; Hu, Yihong; Zhang, Chiyu

    2016-11-23

    Human coronaviruses HCoV-OC43, HCoV-229E, HCoV-NL63 and HCoV-HKU1 are common respiratory viruses associated with acute respiratory infection. They have a global distribution. Rapid and accurate diagnosis of HCoV infection is important for the management and treatment of hospitalized patients with HCoV infection. Here, we developed a melting curve-based multiplex RT-qPCR assay for simultaneous detection of the four HCoVs. In the assay, SYTO 9 was used to replace SYBR Green I as the fluorescent dye, and GC-modified primers were designed to improve the melting temperature (Tm) of the specific amplicon. The four HCoVs were clearly distinguished by characteristic melting peaks in melting curve analysis. The detection sensitivity of the assay was 3 × 10² copies for HCoV-OC43, and 3 × 10¹ copies for HCoV-NL63, HCoV-229E and HCoV-HKU1 per 30 μL reaction. Clinical evaluation and sequencing confirmation demonstrated that the assay was specific and reliable. The assay represents a sensitive and reliable method for diagnosis of HCoV infection in clinical samples.

  17. Blood free-circulating DNA testing by highly sensitive methylation assay to diagnose colorectal neoplasias.

    PubMed

    Suehiro, Yutaka; Hashimoto, Shinichi; Higaki, Shingo; Fujii, Ikuei; Suzuki, Chieko; Hoshida, Tomomi; Matsumoto, Toshihiko; Yamaoka, Yuko; Takami, Taro; Sakaida, Isao; Yamasaki, Takahiro

    2018-03-30

    Although methylated TWIST1 is a biomarker of colorectal neoplasia, its detection from serum samples is very difficult by conventional bisulfite-based methylation assays. Therefore, we have developed a new methylation assay that enables counting of even one copy of a methylated gene in a small DNA sample amount without DNA bisulfite treatment. We performed this study to evaluate the sensitivity and specificity of serum DNA testing by the new methylation assay in combination with and without the fecal immunochemical test for hemoglobin for the detection of colorectal neoplasia. This study comprised 113 patients with colorectal neoplasia and 25 control individuals. For the new methylation assay, DNA was treated in two stages with methylation-sensitive restriction enzymes, followed by measurement of copy numbers of hTERT and methylated TWIST1 by multiplex droplet digital PCR. The fecal immunochemical test had a sensitivity of 8.0% for non-advanced adenoma, 24.3% for advanced adenoma, and 44.4% for colorectal cancer, and a specificity of 88.0%. The new assay had a sensitivity of 36.0% for non-advanced adenoma, 30.0% for advanced adenoma, and 44.4% for colorectal cancer, and a specificity of 92.0%. Combination of the both tests increased the sensitivity to 40.0%, 45.7%, and 72.2% for the detection of non-advanced adenoma, advanced adenoma, and colorectal cancer, respectively, and resulted in a specificity of 84.0%. Combination of both tests may provide an alternative screening strategy for colorectal neoplasia including potentially precancerous lesions and colorectal cancer.

  18. Detection, differentiation, and VP1 sequencing of duck hepatitis A virus type 1 and type 3 by a 1-step duplex reverse-transcription PCR assay.

    PubMed

    Wen, X J; Cheng, A C; Wang, M S; Jia, R Y; Zhu, D K; Chen, S; Liu, M F; Liu, F; Chen, X Y

    2014-09-01

    Duck hepatitis A virus (DHAV) is an infectious pathogen causing fatal duck viral hepatitis in ducklings. Although both the inactivated vaccines and live attenuated vaccines have been used to protect ducklings, DHAV-1 and DHAV-3 still cause significant serious damage to the duck industry in China and South Korea. For rapid detection, differentiation, and epidemic investigation of DHAV in China, a genotype-specific 1-step duplex reverse-transcription (RT) PCR assay was established in this study. The sensitivity and specificity of the developed RT-PCR assay was evaluated with nucleic acids extracted from 2 DHAV reference strains, and 9 other infectious viruses and bacteria. The genotype-specific primers amplified different size DNA fragments encompassing the complete VP1 gene of the DHAV-1 or DHAV-3. The assay detected the liver samples collected from experimentally infected ducklings and dead ducklings collected from different regions of China. Sequence analysis of these DNA fragments indicated that VP1 sequences of DHAV-1 can be used to distinguish wild type and vaccine strains. The phylogenetic analysis of VP1 sequences indicated that the developed RT-PCR assay can be used for epidemic investigation of DHAV-1 and DHAV-3. The developed RT-PCR assay can be used as a specific molecular tool for simultaneous detection, differentiation, and sequencing the VP1 gene of DHAV-1 and DHAV-3, which can be used for understanding the epidemiology and evolution of DHAV. © 2014 Poultry Science Association Inc.

  19. An improved Abbott ARCHITECT assay for the detection of hepatitis B virus surface antigen (HBsAg).

    PubMed

    Lou, Sheng C; Pearce, Sandra K; Lukaszewska, Teresa X; Taylor, Russell E; Williams, Gregg T; Leary, Thomas P

    2011-05-01

    The sensitive and accurate detection of hepatitis B virus surface antigen (HBsAg) is critical to the identification of infection and the prevention of transfusion transmitted disease. Improvement in HBsAg assay sensitivity is essential to reduce the window to detect an acute HBV infection. Additionally, the sensitive detection of HBsAg mutants that continue to evolve due to vaccine escape, immune selection and an error prone reverse transcriptase is a necessity. A fully automated HBsAg prototype assay on the Abbott ARCHITECT instrument was developed to improve sensitivity and mutant detection. This magnetic microparticle-based assay utilizes anti-HBsAg monoclonal antibodies to capture antigen present in serum or plasma. Captured antigen is then detected using anti-HBsAg antibody conjugated with the chemiluminescent compound, acridinium. The sensitivity of the ARCHITECT HBsAg prototype assay was improved as compared to the current ARCHITECT, PRISM, and competitor HBsAg assays. The enhancement in assay sensitivity was demonstrated by the use of commercially available HBV seroconversion panels. The prototype assay detected more panel members (185 of 383) vs. the current ARCHITECT (171), PRISM (181), or competitor HBsAg assays (73/140 vs. 62/140, respectively). The ARCHITECT prototype assay also efficiently detected all mutants evaluated. Finally, the sensitivity improvement did not compromise the specificity of the assay (99.94%). An improved Abbott ARCHITECT HBsAg prototype assay with enhanced detection of HBsAg and HBsAg mutants, as well as equivalent specificity was developed for the detection, diagnosis, and management of HBV infection. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. A DNA microarray-based assay to detect dual infection with two dengue virus serotypes.

    PubMed

    Díaz-Badillo, Alvaro; Muñoz, María de Lourdes; Perez-Ramirez, Gerardo; Altuzar, Victor; Burgueño, Juan; Mendoza-Alvarez, Julio G; Martínez-Muñoz, Jorge P; Cisneros, Alejandro; Navarrete-Espinosa, Joel; Sanchez-Sinencio, Feliciano

    2014-04-25

    Here; we have described and tested a microarray based-method for the screening of dengue virus (DENV) serotypes. This DNA microarray assay is specific and sensitive and can detect dual infections with two dengue virus serotypes and single-serotype infections. Other methodologies may underestimate samples containing more than one serotype. This technology can be used to discriminate between the four DENV serotypes. Single-stranded DNA targets were covalently attached to glass slides and hybridised with specific labelled probes. DENV isolates and dengue samples were used to evaluate microarray performance. Our results demonstrate that the probes hybridized specifically to DENV serotypes; with no detection of unspecific signals. This finding provides evidence that specific probes can effectively identify single and double infections in DENV samples.

  1. A DNA Microarray-Based Assay to Detect Dual Infection with Two Dengue Virus Serotypes

    PubMed Central

    Díaz-Badillo, Alvaro; de Lourdes Muñoz, María; Perez-Ramirez, Gerardo; Altuzar, Victor; Burgueño, Juan; Mendoza-Alvarez, Julio G.; Martínez-Muñoz, Jorge P.; Cisneros, Alejandro; Navarrete-Espinosa, Joel; Sanchez-Sinencio, Feliciano

    2014-01-01

    Here; we have described and tested a microarray based-method for the screening of dengue virus (DENV) serotypes. This DNA microarray assay is specific and sensitive and can detect dual infections with two dengue virus serotypes and single-serotype infections. Other methodologies may underestimate samples containing more than one serotype. This technology can be used to discriminate between the four DENV serotypes. Single-stranded DNA targets were covalently attached to glass slides and hybridised with specific labelled probes. DENV isolates and dengue samples were used to evaluate microarray performance. Our results demonstrate that the probes hybridized specifically to DENV serotypes; with no detection of unspecific signals. This finding provides evidence that specific probes can effectively identify single and double infections in DENV samples. PMID:24776933

  2. Evaluation of the DCA Vantage analyzer for HbA 1c assay.

    PubMed

    Szymezak, Jean; Leroy, Nathalie; Lavalard, Emmanuelle; Gillery, Philippe

    2008-01-01

    Measurement of HbA 1c is key in monitoring diabetic patients in both laboratories and clinical units, where HbA 1c results are used as part of patient education. We have evaluated the DCA Vantage, a new device for immunological assay of HbA 1c. HbA 1c results obtained were evaluated in terms of precision, linearity, specificity and practicability, and were compared with results obtained by a Variant II HPLC method. The method exhibited intra- and inter-assay coefficients of variation lower than 2.6% and 4.0%, respectively, and good correlation with the comparison HPLC method (r2=0.9776). No interference was noted in the presence of labile HbA 1c or carbamylated hemoglobin. The new device exhibited improved practicability characteristics and allowed better sample identification, better management of quality control routines and greater connectivity possibilities compared to the previous DCA 2000 analyzer. This new analyzer exhibited analytical and practical characteristics very suitable for HbA 1c assay for laboratory or point-of-care use according to good laboratory practice.

  3. Inferring biomarkers for Mycobacterium avium subsp. paratuberculosis infection and disease progression in cattle using experimental data

    NASA Astrophysics Data System (ADS)

    Magombedze, Gesham; Shiri, Tinevimbo; Eda, Shigetoshi; Stabel, Judy R.

    2017-03-01

    Available diagnostic assays for Mycobacterium avium subsp. paratuberculosis (MAP) have poor sensitivities and cannot detect early stages of infection, therefore, there is need to find new diagnostic markers for early infection detection and disease stages. We analyzed longitudinal IFN-γ, ELISA-antibody and fecal shedding experimental sensitivity scores for MAP infection detection and disease progression. We used both statistical methods and dynamic mathematical models to (i) evaluate the empirical assays (ii) infer and explain biological mechanisms that affect the time evolution of the biomarkers, and (iii) predict disease stages of 57 animals that were naturally infected with MAP. This analysis confirms that the fecal test is the best marker for disease progression and illustrates that Th1/Th2 (IFN-γ/ELISA antibodies) assays are important for infection detection, but cannot reliably predict persistent infections. Our results show that the theoretical simulated macrophage-based assay is a potential good diagnostic marker for MAP persistent infections and predictor of disease specific stages. We therefore recommend specifically designed experiments to test the use of a based assay in the diagnosis of MAP infections.

  4. Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification

    PubMed Central

    Pannus, Pieter; Claus, Maarten; Gonzalez, Maria Mercedes Perez; Ford, Nathan; Fransen, Katrien

    2016-01-01

    Abstract The use of dried blood spots (DBS) instead of plasma as a specimen type for HIV-1 viral load (VL) testing facilitates the decentralization of specimen collection and can increase access to VL testing in resource-limited settings. The performance of DBS for VL testing is lower, however, when compared to the gold standard sample type plasma. In this diagnostic accuracy study, we evaluated 3 VL assays with DBS. Participants were recruited between August 2012 and April 2015. Both plasma and DBS specimens were prepared and tested for HIV-1 VL with the Roche CAP/CTM HIV-1 test v2.0, the Abbott RealTime HIV-1, and the bioMérieux NucliSENS EasyQ HIV-1 v2.0. Sensitivity and specificity to detect treatment failure at a threshold of 1000 cps/mL with DBS were determined. A total of 272 HIV-positive patients and 51 HIV-negative people were recruited in the study. The mean difference or bias between plasma and DBS VL was <0.5 log cps/mL with all 3 assays but >25% of the specimens differed by >0.5 log cps/mL. All 3 assays had comparable sensitivities around 80% and specificities around 90%. Upward misclassification rates were around 10%, but downward misclassification rates ranged from 20.3% to 23.6%. Differences in between assays were not statistically significant (P > 0.1). The 3 VL assays evaluated had suboptimal performance with DBS but still performed better than immunological or clinical monitoring. Even after the introduction of the much-anticipated point-of-care VL devices, it is expected that DBS will remain important as a complementary option for supporting access to VL monitoring, particularly in rural, resource-limited settings. Manufacturers should accelerate efforts to develop more reliable, sensitive and specific methods to test VL on DBS specimens. PMID:27902602

  5. Validation and comparison of two NGS assays for the detection of EGFR T790M resistance mutation in liquid biopsies of NSCLC patients.

    PubMed

    Vollbrecht, Claudia; Lehmann, Annika; Lenze, Dido; Hummel, Michael

    2018-04-06

    Analysis of circulating cell-free DNA (cfDNA) derived from peripheral blood ("liquid biopsy") is an attractive alternative to identify non-small cell lung cancer (NSCLC) patients with the EGFR T790M mutation eligible for 3rd generation tyrosine kinase inhibitor therapy. We evaluated two PCR-based next generation sequencing (NGS) approaches, one including unique molecular identifiers (UMI), with focus on highly sensitive EGFR T790M mutation detection. Therefore, we extracted and sequenced cfDNA from synthetic plasma samples spiked with mutated DNA at decreasing allele frequencies and from 21 diagnostic NSCLC patients. Data evaluation was performed to determine the limit of detection (LoD), accuracy, specificity and sensitivity of both assays. Considering all tested reference dilutions and mutations the UMI assay performed best in terms of LoD (1% vs. 5%), sensitivity (95.8% vs. 81.3%), specificity (100% vs. 93.8%) and accuracy (96.9% vs. 84.4%). Comparing mutation status of diagnostic samples with both assays showed 81.3% concordance with primary mutation verifiable in 52% of cases. EGFR T790M was detected concordantly in 6/7 patients with allele frequencies from 0.1% to 27%. In one patient, the T790M mutation was exclusively detectable with the UMI assay. Our data demonstrate that both assays are applicable as multi-biomarker NGS tools enabling the simultaneous detection of primary EGFR driver and resistance mutations. However, for mutations with low allelic frequencies the use of NGS panels with UMI facilitates a more sensitive and reliable detection.

  6. Validation and comparison of two NGS assays for the detection of EGFR T790M resistance mutation in liquid biopsies of NSCLC patients

    PubMed Central

    Vollbrecht, Claudia; Lehmann, Annika; Lenze, Dido; Hummel, Michael

    2018-01-01

    Analysis of circulating cell-free DNA (cfDNA) derived from peripheral blood (“liquid biopsy”) is an attractive alternative to identify non-small cell lung cancer (NSCLC) patients with the EGFR T790M mutation eligible for 3rd generation tyrosine kinase inhibitor therapy. We evaluated two PCR-based next generation sequencing (NGS) approaches, one including unique molecular identifiers (UMI), with focus on highly sensitive EGFR T790M mutation detection. Therefore, we extracted and sequenced cfDNA from synthetic plasma samples spiked with mutated DNA at decreasing allele frequencies and from 21 diagnostic NSCLC patients. Data evaluation was performed to determine the limit of detection (LoD), accuracy, specificity and sensitivity of both assays. Considering all tested reference dilutions and mutations the UMI assay performed best in terms of LoD (1% vs. 5%), sensitivity (95.8% vs. 81.3%), specificity (100% vs. 93.8%) and accuracy (96.9% vs. 84.4%). Comparing mutation status of diagnostic samples with both assays showed 81.3% concordance with primary mutation verifiable in 52% of cases. EGFR T790M was detected concordantly in 6/7 patients with allele frequencies from 0.1% to 27%. In one patient, the T790M mutation was exclusively detectable with the UMI assay. Our data demonstrate that both assays are applicable as multi-biomarker NGS tools enabling the simultaneous detection of primary EGFR driver and resistance mutations. However, for mutations with low allelic frequencies the use of NGS panels with UMI facilitates a more sensitive and reliable detection. PMID:29719623

  7. Identification of and Screening for Human Helicobacter cinaedi Infections and Carriers via Nested PCR

    PubMed Central

    Oyama, Kohta; Khan, Shahzada; Okamoto, Tatsuya; Fujii, Shigemoto; Ono, Katsuhiko; Matsunaga, Tetsuro; Yoshitake, Jun; Sawa, Tomohiro; Tomida, Junko; Kawamura, Yoshiaki

    2012-01-01

    Helicobacter cinaedi is the most frequently reported enterohepatic Helicobacter species isolated from humans. Earlier research suggested that certain patients with H. cinaedi infection may remain undiagnosed or incorrectly diagnosed because of difficulties in detecting the bacteria by conventional culture methods. Here, we report a nested PCR assay that rapidly detects the cytolethal distending toxin gene (cdt) of H. cinaedi with high specificity and sensitivity. Specificity of the assay was validated by using different species of Helicobacter and Campylobacter, as well as known H. cinaedi-positive and -negative samples. The sensitivity of detection for the cdt gene in the assay was 102 CFU/ml urine or 102 CFU/105 infected RAW 264.7 cells. In an H. cinaedi-infected mouse model, the cdt gene of H. cinaedi was effectively detected via the assay with urine (6/7), stool (2/3), and blood (2/6) samples. Importantly, it detected H. cinaedi in blood, urine, and stool samples from one patient with a suspected H. cinaedi infection and three patients with known infections. The assay was further used clinically to follow up two H. cinaedi-infected patients after antibiotic treatment. Stool samples from these two patients evaluated by nested PCR after antibiotic therapy showed clearance of bacterial DNA. Finally, analysis of stool specimens from healthy volunteers showed occasional positive reactions (4/30) to H. cinaedi DNA, which suggests intestinal colonization by H. cinaedi in healthy subjects. In conclusion, this nested PCR assay may be useful for the rapid diagnosis, antimicrobial treatment evaluation, and epidemiological study of H. cinaedi infection. PMID:23015666

  8. Final Report Nucleic Acid System - Hybrid PCR and Multiplex Assay Project Phase 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koopman, R P; Langlois, R G; Nasarabadi, S

    2002-04-17

    This report covers phase 2 (year 2) of the Nucleic Acid System--Hybrid PCR and Multiplex Assay project. The objective of the project is to reduce to practice the detection and identification of biological warfare pathogens by the nucleic acid recognition technique of PCR (polymerase chain reaction) in a multiplex mode using flow cytometry. The Hybrid instrument consists of a flow-through PCR module capable of handling a multiplexed PCR assay, a hybridizing module capable of hybridizing multiplexed PCR amplicons and beads, and a flow cytometer module for bead-based identification, all controlled by a single computer. Multiplex immunoassay using bead-based Luminex flowmore » cytometry is available, allowing rapid screening for many agents. PCR is highly specific and complements and verifies immunoassay. It can also be multiplexed and detection provided using the bead-based Luminex flow cytometer. This approach allows full access to the speed and 100-fold multiplex capability of flow cytometry for rapid screening as well as the accuracy and specificity of PCR. This project has two principal activities: (1) Design, build and test a prototype hybrid PCR/flow cytometer with the basic capabilities for rapid, broad spectrum detection and identification, and (2) Develop and evaluate multiplex flow analysis assay protocols and reagents for the simultaneous detection of PCR products. This project requires not only building operationally functional instrumentation but also developing the chemical assays for detection of priority pathogens. This involves development and evaluation of multiplex flow analysis assay protocols and reagents for the simultaneous detection of PCR products.« less

  9. Evaluation of an immunochromatographic assay for the detection of anti-hepatitis A virus IgM

    PubMed Central

    2010-01-01

    Background Hepatitis A virus (HAV) is a causative agent of acute hepatitis, which is transmitted by person-to-person contact and via the faecal-oral route. Acute HAV infection is usually confirmed by anti-HAV IgM detection. In order to detect anti-HAV IgM in the serum of patients infected with HAV, we developed a rapid assay based on immunochromatography (ICA) and evaluated the sensitivity of this assay by comparing it with a commercial microparticle enzyme immunoassay (MEIA) that is widely used for serological diagnosis. Results The newly developed ICA showed 100% sensitivity and specificity when used to test 150 anti-HAV IgM-positive sera collected from infected patients and 75 negative sera from healthy subjects. Also, the sensitivity of ICA is about 10 times higher than MEIA used in this study by determining end point to detect independent on infected genotype of HAV. In addition, the ICA was able to detect 1 positive sample from among 50 sera from acute hepatitis patients that had tested negative for anti-HAV IgM using the MEIA. Conclusion Conclusively, ICA for the detection of anti-HAV IgM will be very effective for rapid assay to apply clinical diagnosis and epidemiological investigation on epidemics due to the simplicity, rapidity and specificity. PMID:20637129

  10. Evaluation of a new serological technique for detecting rabies virus antibodies following vaccination.

    PubMed

    Ma, Xiaoyue; Niezgoda, Michael; Blanton, Jesse D; Recuenco, Sergio; Rupprecht, Charles E

    2012-08-03

    Two major techniques are currently used to estimate rabies virus antibody values: neutralization assays, such as the rapid fluorescent focus inhibition test (RFFIT), and enzyme-linked immunosorbent assays (ELISAs). The RFFIT is considered the gold standard assay and has been used to assess the titer of rabies virus neutralizing antibodies for more than three decades. In the late 1970s, ELISA began to be used to estimate the level of rabies virus antibody and has recently been used by some laboratories as an alternate screening test for animal sera. Although the ELISA appears simpler, safer and more efficient, the assay is less sensitive in detecting low values of rabies virus neutralizing antibodies than neutralization tests. This study was designed to evaluate a new ELISA-based method for detecting rabies virus binding antibody. This new technique uses electro-chemi-luminescence labels and carbon electrode plates to detect binding events. In this comparative study, the RFFIT and the new ELISA-based technique were used to evaluate the level of rabies virus antibodies in human and animal serum samples. By using a conservative approximation of 0.15 IU/ml as a cutoff point, the new ELISA-based technique demonstrated a sensitivity of 100% and a specificity of 95% for human samples and for experimental animal samples. The sensitivity and specificity for field animal samples was 96% and 95%, respectively. The preliminary results from this study appear promising and demonstrate a higher sensitivity than traditional ELISA methods. Published by Elsevier Ltd.

  11. Rapid detection and typing of pathogenic nonpneumophila Legionella spp. isolates using a multiplex real-time PCR assay.

    PubMed

    Benitez, Alvaro J; Winchell, Jonas M

    2016-04-01

    We developed a single tube multiplex real-time PCR assay that allows for the rapid detection and typing of 9 nonpneumophila Legionella spp. isolates that are clinically relevant. The multiplex assay is capable of simultaneously detecting and discriminating L. micdadei, L. bozemanii, L. dumoffii, L. longbeachae, L. feeleii, L. anisa, L. parisiensis, L. tucsonensis serogroup (sg) 1 and 3, and L. sainthelensis sg 1 and 2 isolates. Evaluation of the assay with nucleic acid from each of these species derived from both clinical and environmental isolates and typing strains demonstrated 100% sensitivity and 100% specificity when tested against 43 other Legionella spp. Typing of L. anisa, L. parisiensis, and L. tucsonensis sg 1 and 3 isolates was accomplished by developing a real-time PCR assay followed by high-resolution melt (HRM) analysis targeting the ssrA gene. Further typing of L. bozemanii, L. longbeachae, and L. feeleii isolates to the serogroup level was accomplished by developing a real-time PCR assay followed by HRM analysis targeting the mip gene. When used in conjunction with other currently available diagnostic tests, these assays may aid in rapidly identifying specific etiologies associated with Legionella outbreaks, clusters, sporadic cases, and potential environmental sources. Published by Elsevier Inc.

  12. Algorithms for detecting antibodies to HIV-1: results from a rural Ugandan cohort.

    PubMed

    Nunn, A J; Biryahwaho, B; Downing, R G; van der Groen, G; Ojwiya, A; Mulder, D W

    1993-08-01

    To evaluate an algorithm using two enzyme immunoassays (EIA) for anti-HIV-1 antibodies in a rural African population and to assess alternative simplified algorithms. Sera obtained from 7895 individuals in a rural population survey were tested using an algorithm based on two different EIA systems: Recombigen HIV-1 EIA and Wellcozyme HIV-1 Recombinant. Alternative algorithms were assessed using negative or confirmed positive sera. None of the 227 sera classified as unequivocably negative by the two assays were positive by Western blot. Of 192 sera unequivocably positive by both assays, four were seronegative by Western blot. The possibility of technical error cannot be ruled out in three of these. One of the alternative algorithms assessed classified all borderline or discordant assay results as negative had a specificity of 100% and a sensitivity of 98.4%. The cost of this algorithm is one-third that of the conventional algorithm. Our evaluation suggests that high specificity and sensitivity can be obtained without using Western blot and at a considerable reduction in cost.

  13. Evaluation of a multitarget real-time PCR assay for detection of Bordetella species during a pertussis outbreak in New Hampshire in 2011.

    PubMed

    Gao, Fengxiang; Mahoney, Jennifer C; Daly, Elizabeth R; Lamothe, Wendy; Tullo, Daniel; Bean, Christine

    2014-01-01

    A multitarget real-time PCR assay with three targets, including insertion sequence 481 (IS481), IS1001, and an IS1001-like element, as well as pertussis toxin subunit S1 (ptxS1), for the detection of Bordetella species was evaluated during a pertussis outbreak. The sensitivity and specificity were 77 and 88% (PCR) and 66 and 100% (culture), respectively. All patients with an IS481 C(T) of <30 also tested positive by ptxS1 assay and were clinical pertussis cases. No patients with IS481 C(T) values of ≥40 tested positive by culture. Therefore, we recommend that culture be performed only for specimens with IS481 C(T) values of 30 ≤ CT <40.

  14. Evaluation of a Multitarget Real-Time PCR Assay for Detection of Bordetella Species during a Pertussis Outbreak in New Hampshire in 2011

    PubMed Central

    Mahoney, Jennifer C.; Daly, Elizabeth R.; Lamothe, Wendy; Tullo, Daniel; Bean, Christine

    2014-01-01

    A multitarget real-time PCR assay with three targets, including insertion sequence 481 (IS481), IS1001, and an IS1001-like element, as well as pertussis toxin subunit S1 (ptxS1), for the detection of Bordetella species was evaluated during a pertussis outbreak. The sensitivity and specificity were 77 and 88% (PCR) and 66 and 100% (culture), respectively. All patients with an IS481 CT of <30 also tested positive by ptxS1 assay and were clinical pertussis cases. No patients with IS481 CT values of ≥40 tested positive by culture. Therefore, we recommend that culture be performed only for specimens with IS481 CT values of 30 ≤ CT <40. PMID:24131698

  15. Clinical validation of an epigenetic assay to predict negative histopathological results in repeat prostate biopsies.

    PubMed

    Partin, Alan W; Van Neste, Leander; Klein, Eric A; Marks, Leonard S; Gee, Jason R; Troyer, Dean A; Rieger-Christ, Kimberly; Jones, J Stephen; Magi-Galluzzi, Cristina; Mangold, Leslie A; Trock, Bruce J; Lance, Raymond S; Bigley, Joseph W; Van Criekinge, Wim; Epstein, Jonathan I

    2014-10-01

    The DOCUMENT multicenter trial in the United States validated the performance of an epigenetic test as an independent predictor of prostate cancer risk to guide decision making for repeat biopsy. Confirming an increased negative predictive value could help avoid unnecessary repeat biopsies. We evaluated the archived, cancer negative prostate biopsy core tissue samples of 350 subjects from a total of 5 urological centers in the United States. All subjects underwent repeat biopsy within 24 months with a negative (controls) or positive (cases) histopathological result. Centralized blinded pathology evaluation of the 2 biopsy series was performed in all available subjects from each site. Biopsies were epigenetically profiled for GSTP1, APC and RASSF1 relative to the ACTB reference gene using quantitative methylation specific polymerase chain reaction. Predetermined analytical marker cutoffs were used to determine assay performance. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay resulted in a negative predictive value of 88% (95% CI 85-91). In multivariate models correcting for age, prostate specific antigen, digital rectal examination, first biopsy histopathological characteristics and race the test proved to be the most significant independent predictor of patient outcome (OR 2.69, 95% CI 1.60-4.51). The DOCUMENT study validated that the epigenetic assay was a significant, independent predictor of prostate cancer detection in a repeat biopsy collected an average of 13 months after an initial negative result. Due to its 88% negative predictive value adding this epigenetic assay to other known risk factors may help decrease unnecessary repeat prostate biopsies. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Development and evaluation of a simple and effective RT-qPCR inhibitory assay for detection of the efficacy of compounds towards HIV reverse transcriptase.

    PubMed

    Marino-Merlo, Francesca; Frezza, Caterina; Papaianni, Emanuela; Valletta, Elena; Mastino, Antonio; Macchi, Beatrice

    2017-11-01

    Assessing the actual efficacy of compounds to directly inhibit HIV reverse transcriptase (RT) activity is a main goal in preclinical antiretroviral studies. Our previous studies demonstrated that the effects of inhibitor compounds towards HIV-RT could be efficiently assessed through a simple cell-free assay based on conventional reverse transcription PCR. In the present study, we describe a modified variant of our assay, termed RT real-time quantitative PCR inhibitory assay (RT-qPCR-IA), in which the ability of compounds to restrict the complementary DNA (cDNA) generation by HIV-RT using a specific RNA template is performed by the real-time technique, in order to improve both accuracy and sensitivity of the method. As specific RNA template, RNA extracted from stable transfectants ectopically expressing the herpes simplex virus 1 glycoprotein D gene was utilized. HIV-RT, of both commercial or house-made viral lysate origin, was employed for the assay. To assess the reliability of RT-qPCR-IA, we performed a comparative, quantitative analysis of the dose-dependent effect exerted by known nucleotide and non-nucleotide reverse-transcriptase inhibitors, using the SYBR Green dye chemistry as detection system. The results obtained with RT-qPCR-IA were compared to that obtained using a one-step PicoGreen technology-based commercial kit. The outcome of our study indicates that the development of the novel RT-qPCR-IA will provide rapid and accurate evaluation of the inhibitory efficacy of compounds towards HIV-RT activity. This evaluation could be very useful for large-scale screening of potential new anti-HIV drugs.

  17. Direct detection and characterization of foot-and-mouth disease virus in East Africa using a field-ready real-time PCR platform.

    PubMed

    Howson, E L A; Armson, B; Lyons, N A; Chepkwony, E; Kasanga, C J; Kandusi, S; Ndusilo, N; Yamazaki, W; Gizaw, D; Cleaveland, S; Lembo, T; Rauh, R; Nelson, W M; Wood, B A; Mioulet, V; King, D P; Fowler, V L

    2018-02-01

    Effective control and monitoring of foot-and-mouth disease (FMD) relies upon rapid and accurate disease confirmation. Currently, clinical samples are usually tested in reference laboratories using standardized assays recommended by The World Organisation for Animal Health (OIE). However, the requirements for prompt and serotype-specific diagnosis during FMD outbreaks, and the need to establish robust laboratory testing capacity in FMD-endemic countries have motivated the development of simple diagnostic platforms to support local decision-making. Using a portable thermocycler, the T-COR™ 8, this study describes the laboratory and field evaluation of a commercially available, lyophilized pan-serotype-specific real-time RT-PCR (rRT-PCR) assay and a newly available FMD virus (FMDV) typing assay (East Africa-specific for serotypes: O, A, Southern African Territories [SAT] 1 and 2). Analytical sensitivity, diagnostic sensitivity and specificity of the pan-serotype-specific lyophilized assay were comparable to that of an OIE-recommended laboratory-based rRT-PCR (determined using a panel of 57 FMDV-positive samples and six non-FMDV vesicular disease samples for differential diagnosis). The FMDV-typing assay was able to correctly identify the serotype of 33/36 FMDV-positive samples (no cross-reactivity between serotypes was evident). Furthermore, the assays were able to accurately detect and type FMDV RNA in multiple sample types, including epithelial tissue suspensions, serum, oesophageal-pharyngeal (OP) fluid and oral swabs, both with and without the use of nucleic acid extraction. When deployed in laboratory and field settings in Tanzania, Kenya and Ethiopia, both assays reliably detected and serotyped FMDV RNA in samples (n = 144) collected from pre-clinical, clinical and clinically recovered cattle. These data support the use of field-ready rRT-PCR platforms in endemic settings for simple, highly sensitive and rapid detection and/or characterization of FMDV. © 2017 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  18. Diagnostic value of ex vivo pleural fluid interferon-gamma versus adapted whole-blood quantiferon-TB gold in tube assays in tuberculous pleural effusion

    PubMed Central

    Eldin, Eman N.; Omar, Asmaa; Khairy, Mahmoud; Mekawy, Adel H. M.; Ghanem, Maha K.

    2012-01-01

    BACKGROUND: Noninvasive diagnosis of pleural tuberculosis (TB) remains a challenge due to the paucibacillary nature of the disease. As Mycobacterium tuberculosis (MTB)-specific T cells are recruited into pleural space in TB effusion; their indirect detection may provide useful clinical information. OBJECTIVES: Evaluation of pleural fluid interferon (INF)-γ levels vs Quantiferon–TB Gold In tube assay (QFT- IT) in blood and its adapted variants, using pleural fluid or isolated pleural fluid cells in the diagnosis of pleural TB. METHODS: Thirty-eight patients with pleural effusion of unknown etiology presented at Assiut University Hospital, Egypt, were recruited. Blood and pleural fluid were collected at presentation for INF-γ assays. Ex vivo pleural fluid INF-γ levels, QFT-IT in blood and its adapted variants were compared with final diagnosis as confirmed by other tools including blind and/or thoracoscopic pleural biopsy. RESULTS: The final clinical diagnosis was TB in 20 (53%), malignancy in 10 (26%), and effusion due to other causes in eight patients (21%). Ex vivo pleural fluid INF-γ levels accurately identified TB in all patients and were superior to the QFT-IT assays using blood or pleural fluid (70 and 78% sensitivity, with 60 and 83% specificity, respectively). QFT-IT assay applied to isolated pleural fluid cells had 100% sensitivity and 72% specificity. The optimal cut-off obtained with ROC analysis was 0.73 for TB Gold assay in blood assay, 0.82 IU/ml for the cultured pleural fluid assay, and 0.94 for isolated pleural cells assay. CONCLUSION: The ex vivo pleural fluid INF-γ level is an accurate marker for the diagnosis of pleural TB. QFT- IT assay in peripheral blood or its adapted versions of the assay using pleural fluid and/or washed pleural fluid cells had no diagnostic advantage over pleural fluid INF-γ in the diagnosis of pleural TB. PMID:23189099

  19. A comparison of two ELISAs for the detection of antibodies to bovine leucosis virus in bulk-milk.

    PubMed

    Ridge, S E; Galvin, J W

    2005-07-01

    To estimate the sensitivity, specificity and detection limits for two bulk-milk enzyme-linked immunosorbent assays, the Svanovir BLV-gp51-Ab and the Lactelisa BLV Ab Bi indirect tank 250, for the detection of antibody to bovine leucosis virus in milk. Milk samples from 27 cows known to have enzootic bovine leucosis (EBL) were serially diluted with milk from a herd known to be free from the disease. The dilution at which antibodies could no longer be detected by each test was determined. A total of 1959 bulk-milk samples submitted to a laboratory for the Victorian (EBL) eradication program were tested with both the Svanovir and the Lactelisa assays. A Bayesian approach was used to calculate maximum-likelihood estimates of test sensitivity and specificity. An additional 660 bulk-milk samples were tested with both the Svanovir and the Lactelisa assays. Herds that had positive results on either or both of the assays were subjected to blood or milk testing of individual cattle. The dilution of milk at which the Svanovir assay failed to detect enzootic bovine leucosis antibody in half of the samples was 1 in 40, whereas the comparable value for the Lactelisa was 1 in 200. Computer modeling of the operating characteristics of the Svanovir assay indicated that the sensitivity of that assay would be considerably lower than that for the Lactelisa, and the specificity was estimated to be higher. Evaluation of the assays using 660 bulk-milk samples showed that the Lactelisa assay detected four infected herds that were not detected by the Svanovir test. No false positive results were recorded for either assay. Use of the Lactelisa assay in the Victorian EBL eradication program will enhance disease detection and eradication, but may also result in an increased frequency of false positive bulk-milk test results.

  20. Development and validation of a real-time TaqMan assay for the detection and enumeration of Pseudomonas fluorescens ATCC 13525 used as a challenge organism in testing of food equipments.

    PubMed

    Saha, Ratul; Bestervelt, Lorelle L; Donofrio, Robert S

    2012-02-01

    Pseudomonas fluorescens ATCC 13525 is used as the challenge organism to evaluate the efficacy of the clean-in-place (CIP) process of food equipment (automatic ice-maker) as per NSF/ANSI Standard 12. Traditional culturing methodology is presently used to determine the concentration of the challenge organism, which takes 48 h to confirm the cell density. Storage of the challenge preparation in the refrigerator might alter the cell density as P. fluorescens is capable of growing at 4 °C. Also, background organism can grow on the Pseudomonas F agar (PFA) used for the recovery of P. fluorescens thus affecting the results of the test. Real-time TaqMan assay targeting the cpn60 gene was developed for the enumeration and the identification of P. fluorescens because of its specificity, accuracy, and shorter turnaround time. The TaqMan primer-probe pair developed using the Allele ID® 7.0 probe design software was highly specific and sensitive for the target organism. The sensitivity of the assay was 10 colony forming units (CFU)/mL. The assay was also successful in determining the concentration of the challenge preparation within 2 h. Based on these observations, TaqMan assay targeting the cpn60 gene can be efficiently used for strain level identification and enumeration of bacteria. Pseudomonas fluorescens ATCC 13525 is used as a challenge organism in the efficacy testing of clean-in-place process of food equipments. Currently, culturing technique is used for its identification and estimation, which is not only time-consuming but also prone to error. Real-time TaqMan assay is more specific, sensitive, and accurate along with a shorter turnaround time compared to culturing techniques, thereby increasing the overall quality of the testing methodology to evaluate the clean-in-place process critical for the food industry to protect public health and safety. © 2012 Institute of Food Technologists®

  1. Development of a rapid loop-mediated isothermal amplification assay for diagnosis and assessment of cure of Leishmania infection.

    PubMed

    Verma, Sandeep; Singh, Ruchi; Sharma, Vanila; Bumb, Ram Avtar; Negi, Narendra Singh; Ramesh, V; Salotra, Poonam

    2017-03-23

    Leishmaniasis is a spectrum of diseases with great relevance to public health. Conventional diagnostic methods are time consuming, needing trained personnel. A robust, rapid and cost effective diagnostic test is warranted for on-time diagnosis and field application. We have developed a loop mediated isothermal amplification (LAMP) assay with primers (n = 6) based on Leishmania donovani kDNA for detection of Leishmania infection, using a closed tube to prevent cross-contamination. The assay was used to detect Leishmania infection in biological samples obtained from patients of visceral leishmaniasis (VL), post kala-azar dermal leishmaniasis (PKDL) and cutaneous leishmaniasis (CL). The assay was positive for L. donovani, L. tropica and L. major parasites, with the highest sensitivity towards L. donovani (1 fg DNA). The high sensitivity of the assay for detection of L. donovani was reflected in its ability to detect parasite DNA within 30 min of amplification time with a threshold detection limit of ≥25 copies per reaction. The assay detected parasite in 64 of 66 VL blood samples (sensitivity, 96.9%; 95% CI: 89.6-99.2%), 15 of 15 VL bone marrow aspirate samples (sensitivity, 100%; 95% CI:79.6-100%), 65 of 67 PKDL tissue biopsy samples (sensitivity, 97%; 95% CI:89.7-99.2%). The assay was evaluated in a few cases of CL wherein it was found positive in 8 of 10 tissue biopsies (sensitivity, 80%; 95% CI: 49-94.3%). The assay was negative in all control blood (n = 76) and tissue biopsy (n = 24) samples (specificity, 100%; 95% CI: 96.3-100%). Further, the assay was evaluated for its utility in assessment of cure in treated VL and PKDL patients. The assay detected parasite DNA in 2 of 20VL blood samples and 2 of 21 PKDL tissue samples. Out of 4 cases that were positive for parasite DNA at post treatment stage, 2 patients (1VL and 1 PKDL) returned with relapse. The study demonstrated a Leishmania genus specific closed tube LAMP assay for reliable and rapid molecular diagnosis of VL and PKDL with potential for application in assessment of cure.

  2. Detection of Delta9-tetrahydrocannabinol and amphetamine-type stimulants in oral fluid using the Rapid Stat point-of-collection drug-testing device.

    PubMed

    Röhrich, J; Zörntlein, S; Becker, J; Urban, R

    2010-04-01

    The Rapid Stat assay, a point-of-collection drug-testing device for detection of amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in oral fluid, was evaluated for cannabis and amphetamine-type stimulants. The Rapid Stat tests (n = 134) were applied by police officers in routine traffic checks. Oral fluid and blood samples were analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol, amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyethylamphetamine, and methylenedioxyamphetamine. The comparison of GC-MS analysis of oral fluid with the Rapid Stat results for cannabis showed a sensitivity of 85%, a specificity of 87%, and a total confirmation rate of 87%. When compared with serum, the sensitivity of the cannabis assay decreased to 71%, the specificity to 60%, and the total confirmation rate to 66%. These findings were possibly caused by an incorrect reading of the THC test results. Comparison of the Rapid Stat amphetamine assay with GC-MS in oral fluid showed a sensitivity of 94%, a specificity of 97%, and a total confirmation rate of 97%. Compared with serum, a sensitivity of 100%, a specificity of 90%, and a total confirmation rate of 92% was found. The amphetamine assay must, therefore, be regarded as satisfactory.

  3. Molecular beacon probes-base multiplex NASBA Real-time for detection of HIV-1 and HCV.

    PubMed

    Mohammadi-Yeganeh, S; Paryan, M; Mirab Samiee, S; Kia, V; Rezvan, H

    2012-06-01

    Developed in 1991, nucleic acid sequence-based amplification (NASBA) has been introduced as a rapid molecular diagnostic technique, where it has been shown to give quicker results than PCR, and it can also be more sensitive. This paper describes the development of a molecular beacon-based multiplex NASBA assay for simultaneous detection of HIV-1 and HCV in plasma samples. A well-conserved region in the HIV-1 pol gene and 5'-NCR of HCV genome were used for primers and molecular beacon design. The performance features of HCV/HIV-1 multiplex NASBA assay including analytical sensitivity and specificity, clinical sensitivity and clinical specificity were evaluated. The analysis of scalar concentrations of the samples indicated that the limit of quantification of the assay was <1000 copies/ml for HIV-1 and <500 copies/ml for HCV with 95% confidence interval. Multiplex NASBA assay showed a 98% sensitivity and 100% specificity. The analytical specificity study with BLAST software demonstrated that the primers do not attach to any other sequences except for that of HIV-1 or HCV. The primers and molecular beacon probes detected all HCV genotypes and all major variants of HIV-1. This method may represent a relatively inexpensive isothermal method for detection of HIV-1/HCV co-infection in monitoring of patients.

  4. An Enhanced ELISPOT Assay for Sensitive Detection of Antigen-Specific T Cell Responses to Borrelia burgdorferi

    PubMed Central

    Jin, Chenggang; Roen, Diana R.; Lehmann, Paul V.; Kellermann, Gottfried H.

    2013-01-01

    Lyme Borreliosis is an infectious disease caused by the spirochete Borrelia burgdorferi that is transmitted through the bite of infected ticks. Both B cell-mediated humoral immunity and T cell immunity develop during natural Borrelia infection. However, compared with humoral immunity, the T cell response to Borrelia infection has not been well elucidated. In this study, a novel T cell-based assay was developed and validated for the sensitive detection of antigen-specific T cell response to B. burgdorferi. Using interferon-γ as a biomarker, we developed a new enzyme-linked immunospot method (iSpot LymeTM) to detect Borrelia antigen-specific effector/memory T cells that were activated in vivo by exposing them to recombinant Borrelia antigens ex vivo. To test this new method as a potential laboratory diagnostic tool, we performed a clinical study with a cohort of Borrelia positive patients and healthy controls. We demonstrated that the iSpot Lyme assay has a significantly higher specificity and sensitivity compared with the Western Blot assay that is currently used as a diagnostic measure. A comprehensive evaluation of the T cell response to Borrelia infection should, therefore, provide new insights into the pathogenesis, diagnosis, treatment and monitoring of Lyme disease. PMID:24709800

  5. An enzyme-linked immunosorbent assay for detection of botulinum toxin-antibodies.

    PubMed

    Dressler, Dirk; Gessler, Frank; Tacik, Pawel; Bigalke, Hans

    2014-09-01

    Antibodies against botulinum neurotoxin (BNT-AB) can be detected by the mouse protection assay (MPA), the hemidiaphragm assay (HDA), and by enzyme-linked immunosorbent assays (ELISA). Both MPA and HDA require sacrifice of experimental animals, and they are technically delicate and labor intensive. We introduce a specially developed ELISA for detection of BNT-A-AB and evaluate it against the HDA. Thirty serum samples were tested by HDA and by the new ELISA. Results were compared, and receiver operating characteristic analyses were used to optimize ELISA parameter constellation to obtain either maximal overall accuracy, maximal test sensitivity, or maximal test specificity. When the ELISA is optimized for sensitivity, a sensitivity of 100% and a specificity of 55% can be reached. When it is optimized for specificity, a specificity of 100% and a sensitivity of 90% can be obtained. We present an ELISA for BNT-AB detection that can be-for the first time-customized for special purposes. Adjusted for optimal sensitivity, it reaches the best sensitivity of all BNT-AB tests available. Using the new ELISA together with the HDA as a confirmation test allows testing for BNT-AB in large numbers of patients receiving BT drugs in an economical, fast, and more animal-friendly way. © 2014 International Parkinson and Movement Disorder Society.

  6. Rapid Immuno-Chromatographic Assay for the Detection of Antibodies to HIV Compare with Elisa among Voluntary and Replacement Blood Donor of Mymensingh Medical College Hospital.

    PubMed

    Chakrabarty, P; Rudra, S; Hossain, M A; Begum, S A; Mirza, T T; Rudra, M

    2015-04-01

    Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from voluntary and replacement blood donors & HIV-infected patients (positive samples from BSMMU, Dhaka). Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd.), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold™ HIV-1/2 (Biotech) were evaluated between 1st February to 30th June, 2013 using 400 whole blood samples from voluntary and replacement blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Only 01 sample including ten positive samples from BSMMU were confirmed HIV-1 antibody positive, while 399 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9) respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold™, Determine and SD Bioline assays. An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1-100) and 100% specificity (95% CI; 96-99.1) with Uni-Gold™ as tiebreaker for discordant results.

  7. Bayesian estimation of diagnostic sensitivity and specificity of a nervous necrosis virus antibody ELISA.

    PubMed

    Jaramillo, Diana; Dürr, Salome; Hick, Paul; Whittington, Richard

    2016-01-01

    Diagnosis of nervous necrosis virus (NNV) infection in susceptible fish species is mostly performed post-mortem due to the neurotropism of the causative agent and the only validated diagnostic assays require samples from brain and retinal tissue. However, a non-lethal alternative to test for exposure of fish to NNV is needed. An indirect ELISA for the detection of anti-NNV antibodies in was recently developed and evaluated to detect responses in the sera from immunized fish. For this study, we assessed the accuracy of the assay at detecting specific antibodies from naturally exposed fish using field samples from populations with differing infection status. We applied a Bayesian model, using RTqPCR as a second test. Median estimates of the diagnostic sensitivity and specificity of the VNN ELISA were 81.8% and 86.7%, respectively. We concluded that the assay was fit for the purpose of identifying animals in naturally exposed populations. With further evaluation in larger populations the test might be used to inform implementation of control measures, and for estimating infection prevalence to facilitate risk analysis. To our knowledge this is the first report on the diagnostic accuracy of an antibody ELISA for an infectious disease in finfish. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Comparison of glutathione levels measured using optimized monochlorobimane assay with those from ortho-phthalaldehyde assay in intact cells.

    PubMed

    Čapek, Jan; Hauschke, Martina; Brůčková, Lenka; Roušar, Tomáš

    2017-11-01

    Fluorometric glutathione assays have been generally preferred for their high specificity and sensitivity. An additional advantage offered by fluorescent bimane dyes is their ability to penetrate inside the cell. Their ability to react with glutathione within intact cells is frequently useful in flow cytometry and microscopy. Hence, the aims of our study were to use monochlorobimane for optimizing a spectrofluorometric glutathione assay in cells and then to compare that assay with the frequently used ortho-phthalaldehyde assay. We used glutathione-depleting agents (e.g., cisplatin and diethylmalonate) to induce cell impairment. For glutathione assessment, monochlorobimane (40μM) was added to cells and fluorescence was detected at 394/490nm. In addition to the regularly used calculation of glutathione levels from fluorescence change after 60min, we used an optimized calculation from the linear part of the fluorescence curve after 10min of measurement. We found that 10min treatment of cells with monochlorobimane is sufficient for evaluating cellular glutathione concentration and provides results entirely comparable with those from the standard ortho-phthalaldehyde assay. In contrast, the results obtained by the standardly used evaluation after 60min of monochlorobimane treatment provided higher glutathione values. We conclude that measuring glutathione using monochlorobimane with the here-described optimized evaluation of fluorescence signal could be a simple and useful method for routine and rapid assessment of glutathione within intact cells in large numbers of samples. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Monitoring multiple myeloma patients treated with daratumumab: teasing out monoclonal antibody interference.

    PubMed

    McCudden, Christopher; Axel, Amy E; Slaets, Dominique; Dejoie, Thomas; Clemens, Pamela L; Frans, Sandy; Bald, Jaime; Plesner, Torben; Jacobs, Joannes F M; van de Donk, Niels W C J; Moreau, Philippe; Schecter, Jordan M; Ahmadi, Tahamtan; Sasser, A Kate

    2016-06-01

    Monoclonal antibodies are promising anti-myeloma treatments. As immunoglobulins, monoclonal antibodies have the potential to be identified by serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE). Therapeutic antibody interference with standard clinical SPE and IFE can confound the use of these tests for response assessment in clinical trials and disease monitoring. To discriminate between endogenous myeloma protein and daratumumab, a daratumumab-specific immunofixation electrophoresis reflex assay (DIRA) was developed using a mouse anti-daratumumab antibody. To evaluate whether anti-daratumumab bound to and shifted the migration pattern of daratumumab, it was spiked into daratumumab-containing serum and resolved by IFE/SPE. The presence (DIRA positive) or absence (DIRA negative) of residual M-protein in daratumumab-treated patient samples was evaluated using predetermined assessment criteria. DIRA was evaluated for specificity, limit of sensitivity, and reproducibility. In all of the tested samples, DIRA distinguished between daratumumab and residual M-protein in commercial serum samples spiked with daratumumab and in daratumumab-treated patient samples. The DIRA limit of sensitivity was 0.2 g/L daratumumab, using spiking experiments. Results from DIRA were reproducible over multiple days, operators, and assays. The anti-daratumumab antibody was highly specific for daratumumab and did not shift endogenous M-protein. As the treatment of myeloma evolves to incorporate novel monoclonal antibodies, additional solutions will be needed for clinical monitoring of patient responses to therapeutic regimens. In the interim, assays such as DIRA can inform clinical outcomes by distinguishing daratumumab from endogenous M-protein by IFE.

  10. Profile of the Alere i Influenza A & B assay: a pioneering molecular point-of-care test.

    PubMed

    Wang, Hongmei; Deng, Jikui; Tang, Yi-Wei

    2018-05-01

    The Alere i Influenza A & B assay incorporates the Nicking Enzyme Amplification Reaction technique on the Alere i instrument to detect and differentiate influenza virus (Flu) A and B nucleic acids in specific specimens. Areas covered: The Alere i Influenza A & B assay was cleared by the US Food and Drug Administration for use with nasal swabs (NS) and nasopharyngeal swabs, either directly or in viral transport medium. Notably, direct use on NS was the first ever CLIA-waived nucleic acid-based test. Previously published evaluations have reported sensitivities and specificities of 55.2-100% and 62.5-100% for Flu A and 45.2-100% and 53.6-100% for Flu B, respectively. Expert commentary: The Alere i Influenza A & B assay provides a rapid and simple platform for detection and differentiation of Flu A and B. Efforts are expected to further improve sensitivity and user-friendliness for effective and widespread use in the true point-of-care setting.

  11. Development of a loop-mediated isothermal amplification assay for detection of Trichomonas vaginalis.

    PubMed

    Reyes, John Carlo B; Solon, Juan Antonio A; Rivera, Windell L

    2014-07-01

    A loop-mediated isothermal amplification (LAMP) assay targeting the 2-kbp repeated DNA species-specific sequence was developed for detection of Trichomonas vaginalis, the causative agent of trichomoniasis. The analytical sensitivity and specificity of the LAMP assay were evaluated using pooled genital swab and urine specimens, respectively, spiked with T. vaginalis trophozoites. Genital secretion and urine did not inhibit the detection of the parasite. The sensitivity of the LAMP was 10-1000 times higher than the PCR performed. The detection limit of LAMP was 1 trichomonad for both spiked genital swab and urine specimens. Also, LAMP did not exhibit cross-reactivity with closely-related trichomonads, Trichomonas tenax and Pentatrichomonas hominis, and other enteric and urogenital microorganisms, Entamoeba histolytica, Candida albicans, Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus. This is the first report of a LAMP assay for the detection of T. vaginalis and has prospective application for rapid diagnosis and control of trichomoniasis. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. A multiparametric assay for quantitative nerve regeneration evaluation.

    PubMed

    Weyn, B; van Remoortere, M; Nuydens, R; Meert, T; van de Wouwer, G

    2005-08-01

    We introduce an assay for the semi-automated quantification of nerve regeneration by image analysis. Digital images of histological sections of regenerated nerves are recorded using an automated inverted microscope and merged into high-resolution mosaic images representing the entire nerve. These are analysed by a dedicated image-processing package that computes nerve-specific features (e.g. nerve area, fibre count, myelinated area) and fibre-specific features (area, perimeter, myelin sheet thickness). The assay's performance and correlation of the automatically computed data with visually obtained data are determined on a set of 140 semithin sections from the distal part of a rat tibial nerve from four different experimental treatment groups (control, sham, sutured, cut) taken at seven different time points after surgery. Results show a high correlation between the manually and automatically derived data, and a high discriminative power towards treatment. Extra value is added by the large feature set. In conclusion, the assay is fast and offers data that currently can be obtained only by a combination of laborious and time-consuming tests.

  13. Interobserver variability and feasibility of polymerase chain reaction-based assay in distinguishing ischemic colitis from Clostridium difficile colitis in endoscopic mucosal biopsies.

    PubMed

    Wiland, Homer O; Procop, Gary W; Goldblum, John R; Tuohy, Marion; Rybicki, Lisa; Patil, Deepa T

    2013-06-01

    Polymerase chain reaction (PCR)-based assays using stool samples are currently the most effective method of detecting Clostridium difficile. This study examines the feasibility of this assay using mucosal biopsy samples and evaluates the interobserver reproducibility in diagnosing and distinguishing ischemic colitis from C difficile colitis. Thirty-eight biopsy specimens were reviewed and classified by 3 observers into C difficile and ischemic colitis. The findings were correlated with clinical data. PCR was performed on 34 cases using BD GeneOhm C difficile assay. The histologic interobserver agreement was excellent (κ= 0.86) and the agreement between histologic and clinical diagnosis was good (κ = 0.84). All 19 ischemic colitis cases tested negative (100% specificity) and 3 of 15 cases of C difficile colitis tested positive (20% sensitivity). C difficile colitis can be reliably distinguished from ischemic colitis using histologic criteria. The C difficile PCR test on endoscopic biopsy specimens has excellent specificity but limited sensitivity.

  14. Evaluation and optimization of a commercial blocking ELISA for detecting antibodies to influenza A virus for research and surveillance of mallards.

    PubMed

    Shriner, Susan A; VanDalen, Kaci K; Root, J Jeffrey; Sullivan, Heather J

    2016-02-01

    The availability of a validated commercial assay is an asset for any wildlife investigation. However, commercial products are often developed for use in livestock and are not optimized for wildlife. Consequently, it is incumbent upon researchers and managers to apply commercial products appropriately to optimize program outcomes. We tested more than 800 serum samples from mallards for antibodies to influenza A virus with the IDEXX AI MultiS-Screen Ab test to evaluate assay performance. Applying the test per manufacturer's recommendations resulted in good performance with 84% sensitivity and 100% specificity. However, performance was improved to 98% sensitivity and 98% specificity by increasing the recommended cut-off. Using this alternative threshold for identifying positive and negative samples would greatly improve sample classification, especially for field samples collected months after infection when antibody titers have waned from the initial primary immune response. Furthermore, a threshold that balances sensitivity and specificity reduces estimation bias in seroprevalence estimates. Published by Elsevier B.V.

  15. Evaluation of differential representative values between Chinese hamster cells and human lymphocytes in mitomycin C-induced cytogenetic assays and caspase-3 activity.

    PubMed

    Liao, Pei-Hu; Lin, Ruey-Hseng; Yang, Ming-Ling; Li, Yi-Ching; Kuan, Yu-Hsiang

    2012-03-01

    Chinese hamster ovary (CHO) cells, its lung fibroblasts (V79), and human lymphocytes are routinely used in in vitro cytogenetic assays, which include micronuclei (MN), sister chromatid exchange (SCE), and chromosome aberration (CA) assays. Mitomycin C (MMC), a DNA cross-link alkylating agent, is both an anticancer medicine and a carcinogen. To study the differential representative values of cell types in MMC-treated cytogenetic assays and its upstream factor, cysteine aspartic acid-specific protease (caspase)-3. Among the chosen cell types, lymphocytes expressed the highest sensitivity in all three MMC-induced assays, whereas CHO and V79 showed varied sensitivity in different assays. In MN assay, the sensitivity of CHO is higher than or equal to V79; in SCE assay, the sensitivity of CHO is the same as V79; and in CA assay, the sensitivity of CHO is higher than V79. In-depth analysis of CA revealed that in chromatid breaks and dicentrics formation, lymphocyte was the most sensitive of all and CHO was more sensitive than V79; and in acentrics and interchanges formation, lymphocyte was much more sensitive than the others. Furthermore, we found caspase-3 activity plays an important role in MMC-induced cytogenetic assays, with MMC-induced caspase-3 activity resulting in more sensitivity in lymphocytes than in CHO and V79. Based on these findings, lymphocyte will make a suitable predictive or representative control reference in cytogenetic assays and caspase-3 activity with its high specificity, positive predictive value, and sensitivity.

  16. Rapid Detection of Cell-Free Mycobacterium tuberculosis DNA in Tuberculous Pleural Effusion.

    PubMed

    Che, Nanying; Yang, Xinting; Liu, Zichen; Li, Kun; Chen, Xiaoyou

    2017-05-01

    Tuberculous pleurisy is one of the most common types of extrapulmonary tuberculosis, but its diagnosis remains difficult. In this study, we report for the first time on the detection of cell-free Mycobacterium tuberculosis DNA in pleural effusion and an evaluation of a newly developed molecular assay for the detection of cell-free Mycobacterium tuberculosis DNA. A total of 78 patients with pleural effusion, 60 patients with tuberculous pleurisy, and 18 patients with alternative diseases were included in this study. Mycobacterial culture, the Xpert MTB/RIF assay, the adenosine deaminase assay, the T-SPOT.TB assay, and the cell-free Mycobacterium tuberculosis DNA assay were performed on all the pleural effusion samples. The cell-free Mycobacterium tuberculosis DNA assay and adenosine deaminase assay showed significantly higher sensitivities of 75.0% and 68.3%, respectively, than mycobacterial culture and the Xpert MTB/RIF assay, which had sensitivities of 26.7% and 20.0%, respectively ( P < 0.01). All four of these tests showed good specificities: 88.9% for the adenosine deaminase assay and 100% for the remaining three assays. The T-SPOT.TB assay with pleural effusion showed the highest sensitivity of 95.0% but the lowest specificity of 38.9%. The cell-free Mycobacterium tuberculosis DNA assay detected as few as 1.25 copies of IS 6110 per ml of pleural effusion and showed good accordance of the results between repeated tests ( r = 0.978, P = 2.84 × 10 -10 ). These data suggest that the cell-free Mycobacterium tuberculosis DNA assay is a rapid and accurate molecular test which provides direct evidence of Mycobacterium tuberculosis etiology. Copyright © 2017 American Society for Microbiology.

  17. Rapid Detection of Cell-Free Mycobacterium tuberculosis DNA in Tuberculous Pleural Effusion

    PubMed Central

    Yang, Xinting; Liu, Zichen; Li, Kun

    2017-01-01

    ABSTRACT Tuberculous pleurisy is one of the most common types of extrapulmonary tuberculosis, but its diagnosis remains difficult. In this study, we report for the first time on the detection of cell-free Mycobacterium tuberculosis DNA in pleural effusion and an evaluation of a newly developed molecular assay for the detection of cell-free Mycobacterium tuberculosis DNA. A total of 78 patients with pleural effusion, 60 patients with tuberculous pleurisy, and 18 patients with alternative diseases were included in this study. Mycobacterial culture, the Xpert MTB/RIF assay, the adenosine deaminase assay, the T-SPOT.TB assay, and the cell-free Mycobacterium tuberculosis DNA assay were performed on all the pleural effusion samples. The cell-free Mycobacterium tuberculosis DNA assay and adenosine deaminase assay showed significantly higher sensitivities of 75.0% and 68.3%, respectively, than mycobacterial culture and the Xpert MTB/RIF assay, which had sensitivities of 26.7% and 20.0%, respectively (P < 0.01). All four of these tests showed good specificities: 88.9% for the adenosine deaminase assay and 100% for the remaining three assays. The T-SPOT.TB assay with pleural effusion showed the highest sensitivity of 95.0% but the lowest specificity of 38.9%. The cell-free Mycobacterium tuberculosis DNA assay detected as few as 1.25 copies of IS6110 per ml of pleural effusion and showed good accordance of the results between repeated tests (r = 0.978, P = 2.84 × 10−10). These data suggest that the cell-free Mycobacterium tuberculosis DNA assay is a rapid and accurate molecular test which provides direct evidence of Mycobacterium tuberculosis etiology. PMID:28275073

  18. Evaluation of diagnostic assays for the serological detection of Actinobacillus pleuropneumoniae on samples of known or unknown exposure.

    PubMed

    Opriessnig, Tanja; Hemann, Michelle; Johnson, John K; Heinen, Sheila; Giménez-Lirola, Luis G; O'Neill, Kevin C; Hoang, Hai; Yoon, Kyoung-Jin; Gottschalk, Marcelo; Halbur, Patrick G

    2013-01-01

    Accurate diagnosis of exposure to Actinobacillus pleuropneumoniae is important for maintaining negative farms. In the present study, the ability of a dual-plate complement fixation (CF) assay and 3 commercially available enzyme-linked immunosorbent assays (ELISAs; quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3) in detecting serological evidence of A. pleuropneumoniae exposure was compared using serum samples of experimentally infected or vaccinated pigs, or field samples from the United States. Forty-two pigs were divided into groups of 2 pigs and were inoculated with 1 of 15 A. pleuropneumoniae strains representing all known serovars of A. pleuropneumoniae, or with Actinobacillus suis, or were vaccinated with a bacterin containing A. pleuropneumoniae serovar 1, 3, 5, or 7. Serum samples collected at the day of inoculation or vaccination and 7, 14, 21, and 28 days later were used to compare the assays. On samples from experimentally infected pigs, the dual-plate CF assay, quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3 had sensitivities of 0.46, 0.74, 0.13, and 0.13 and specificities of 0.90, 1.0, 1.0, and 1.0, respectively. Vaccinated pigs were identified only by the dual-plate CF assay and the quad-plate ELISA-1. In addition, 90 serum samples with unknown A. pleuropneumoniae exposure collected under field conditions were tested with all assays. The agreement of the 4 assays on field samples was slight to fair. While several assays are available for demonstration of A. pleuropneumoniae exposure, differences in assay targets complicate test choices. Decisions on which assay or combination of assays to use depend on the specific reasons for running the assays.

  19. Correlation of crAssphage-based qPCR markers with culturable and molecular indicators of human fecal pollution in an impacted urban watershed.

    PubMed

    Stachler, Elyse; Akyon, Benay; Aquino de Carvalho, Nathalia; Ference, Christian; Bibby, Kyle

    2018-06-06

    Environmental waters are monitored for fecal pollution to protect public health. Many previously developed human-specific fecal pollution indicators lack adequate sensitivity to be reliably detected in environmental waters or do not correlate well with viral pathogens. Recently, two novel human sewage-associated source tracking qPCR markers were developed based on the bacteriophage crAssphage, CPQ_056 and CPQ_064. These assays are highly human specific, abundant in sewage, and are viral-based, suggesting great promise for environmental application as human fecal pollution indicators. A 30-day sampling study was conducted in an urban stream impacted by combined sewer overflows to evaluate the crAssphage markers' performance in an environmental system. The crAssphage markers were present at concentrations of 4.02-6.04 log10 copies/100 mL throughout the study period, indicating their high abundance and ease of detection in polluted environmental waters. In addition, the crAssphage assays were correlated with rain events, molecular markers for human polyomavirus and HF183, as well as culturable E. coli, enterococci, and somatic coliphage. The CPQ_064 assay correlated strongly to a greater number of biological indicators than the CPQ_056 assay. This study is the first to evaluate both crAssphage qPCR assays in an extended environmental application of crAssphage markers for monitoring of environmental waters. It is also the first study to compare crAssphage marker concentration with other viral-based indicators.

  20. An Evaluation of Quantitative PCR Assays (TaqMan® and SYBR Green) for the Detection of Babesia bigemina and Babesia bovis, and a Novel Fluorescent-ITS1-PCR Capillary Electrophoresis Method for Genotyping B. bovis Isolates

    PubMed Central

    Zhang, Bing; Sambono, Jacqueline L.; Morgan, Jess A. T.; Venus, Bronwyn; Rolls, Peter; Lew-Tabor, Ala E.

    2016-01-01

    Babesia spp. are tick-transmitted haemoparasites causing tick fever in cattle. In Australia, economic losses to the cattle industry from tick fever are estimated at AUD$26 Million per annum. If animals recover from these infections, they become immune carriers. Here we describe a novel multiplex TaqMan qPCR targeting cytochrome b genes for the identification of Babesia spp. The assay shows high sensitivity, specificity and reproducibility, and allows quantification of parasite DNA from Babesia bovis and B. bigemina compared to standard PCR assays. A previously published cytochrome b SYBR Green qPCR was also tested in this study, showing slightly higher sensitivity than the Taqman qPCRs but requires melting curve analysis post-PCR to confirm specificity. The SYBR Green assays were further evaluated using both diagnostic submissions and vaccinated cattle (at 7, 9, 11 and 14 days post-inoculation) showed that B. bigemina can be detected more frequently than B. bovis. Due to fewer circulating parasites, B. bovis detection in carrier animals requires higher DNA input. Preliminary data for a novel fluorescent PCR genotyping based on the Internal Transcribed Spacer 1 region to detect vaccine and field alleles of B. bovis are described. This assay is capable of detecting vaccine and novel field isolate alleles in a single sample. PMID:29056732

  1. Validation and application of quantitative PCR assays using host-specific Bacteroidales genetic markers for swine fecal pollution tracking.

    PubMed

    Fan, Lihua; Shuai, Jiangbing; Zeng, Ruoxue; Mo, Hongfei; Wang, Suhua; Zhang, Xiaofeng; He, Yongqiang

    2017-12-01

    Genome fragment enrichment (GFE) method was applied to identify host-specific bacterial genetic markers that differ among different fecal metagenomes. To enrich for swine-specific DNA fragments, swine fecal DNA composite (n = 34) was challenged against a DNA composite consisting of cow, human, goat, sheep, chicken, duck and goose fecal DNA extracts (n = 83). Bioinformatic analyses of 384 non-redundant swine enriched metagenomic sequences indicated a preponderance of Bacteroidales-like regions predicted to encode metabolism-associated, cellular processes and information storage and processing. After challenged against fecal DNA extracted from different animal sources, four sequences from the clone libraries targeting two Bacteroidales- (genes 1-38 and 3-53), a Clostridia- (gene 2-109) as well as a Bacilli-like sequence (gene 2-95), respectively, showed high specificity to swine feces based on PCR analysis. Host-specificity and host-sensitivity analysis confirmed that oligonucleotide primers and probes capable of annealing to select Bacteroidales-like sequences (1-38 and 3-53) exhibited high specificity (>90%) in quantitative PCR assays with 71 fecal DNAs from non-target animal sources. The two assays also demonstrated broad distributions of corresponding genetic markers (>94% positive) among 72 swine feces. After evaluation with environmental water samples from different areas, swine-targeted assays based on two Bacteroidales-like GFE sequences appear to be suitable quantitative tracing tools for swine fecal pollution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Development of a polymerase chain reaction assay for the specific identification of Burkholderia mallei and differentiation from Burkholderia pseudomallei and other closely related Burkholderiaceae.

    PubMed

    Ulrich, Ricky L; Ulrich, Melanie P; Schell, Mark A; Kim, H Stanley; DeShazer, David

    2006-05-01

    Burkholderia mallei and Burkholderia pseudomallei, the etiologic agents responsible for glanders and melioidosis, respectively, are genetically and phenotypically similar and are category B biothreat agents. We used an in silico approach to compare the B. mallei ATCC 23344 and B. pseudomallei K96243 genomes to identify nucleotide sequences unique to B. mallei. Five distinct B. mallei DNA sequences and/or genes were identified and evaluated for polymerase chain reaction (PCR) assay development. Genomic DNAs from a collection of 31 B. mallei and 34 B. pseudomallei isolates, obtained from various geographic, clinical, and environmental sources over a 70-year period, were tested with PCR primers targeted for each of the B. mallei ATCC 23344-specific nucleotide sequences. Of the 5 chromosomal targets analyzed, only PCR primers designed to bimA(Bm) were specific for B. mallei. These primers were used to develop a rapid PCR assay for the definitive identification of B. mallei and differentiation from all other bacteria.

  3. Evaluation of the Xpert MTB/RIF assay for diagnosis of tuberculosis and rifampin resistance in county-level laboratories in Hunan province, China.

    PubMed

    Hu, Peilei; Bai, Liqiong; Liu, Fengping; Ou, Xichao; Zhang, Zhiying; Yi, Songlin; Chen, Zhongnan; Gong, Daofang; Liu, Binbin; Guo, Jingwei; Tan, Yunhong

    2014-01-01

    The Xpert MTB/RIF showed high sensitivity and specificity in previous studies carried out in different epidemiological and geographical settings and patient populations in high-burden tuberculosis (TB) countries. However, there were little data obtained by validation or demonstration study of the assay in China. In this study, the performance of Xpert MTB/RIF was investigated in two county-level laboratories in Hunan Province, China. Consecutive patients with suspected pulmonary tuberculosis (PTB) and suspicion for multidrug-resistant tuberculosis (MDR-TB) were enrolled. For each patient suspected to have PTB, three sputum specimens (one spot sputum, one night sputum, and one morning sputum) were collected and each sputum was tested with smear microscopy, Löwenstein-Jensen (LJ) culture, and Xpert MTB/RIF test. For comparison across subgroups and testing methods, 95% confidence intervals were calculated. All analyses were done with SPSS 16.0, and P < 0.05 was regarded as significant. For case detection, the sensitivity of Xpert MTB/RIF was 100% for smear- and culture-positive TB and 88.6% for smear-negative and culture-positive TB; the overall sensitivity was 94.5% for all culture-positive patients. The specificity was 99.8%. The sensitivity of Xpert MTB/RIF assay was 22.0% in clinical TB patients and the specificity reached 100.0% in the group of patients who are infected with nontuberculous mycobacteria. For the detection of rifampin resistance, the sensitivity of MTB/RIF RIF-resistance detection was 92.9%, and the specificity was 98.7%. Of the 26 Xpert MTB/RIF-positive and RIF-resistant patients confirmed by LJ proportion tests, 20 (76.9%) patients were infected by MDR-TB. The Xpert MTB/RIF assay is a highly sensitive and specific method for diagnosis of TB and RIF resistance, which will enable it to have the potential to be used in county-level laboratories and lead to the reduction of the infectious pool and improvements in TB control in China. Further evaluations in county-level laboratories for implementing the assay are still required.

  4. Evaluation of Different PCR-Based Assays and LAMP Method for Rapid Detection of Phytophthora infestans by Targeting the Ypt1 Gene

    PubMed Central

    Khan, Mehran; Li, Benjin; Jiang, Yue; Weng, Qiyong; Chen, Qinghe

    2017-01-01

    Late blight, caused by the oomycete Phytophthora infestans, is one of the most devastating diseases affecting potato and tomato worldwide. Early diagnosis of the P. infestans pathogen causing late blight should be the top priority for addressing disease epidemics and management. In this study, we performed a loop-mediated isothermal amplification (LAMP) assay, conventional polymerase chain reaction (PCR), nested PCR, and real-time PCR to verify and compare the sensitivity and specificity of the reaction based on the Ypt1 (Ras-related protein) gene of P. infestans. In comparison with the PCR-based assays, the LAMP technique led to higher specificity and sensitivity, using uncomplicated equipment with an equivalent time frame. All 43 P. infestans isolates, yielded positive detection results using LAMP assay showing no cross reaction with other Phytophthora spp., oomycetes or fungal pathogens. The LAMP assay yielded the lowest detectable DNA concentration (1.28 × 10-4 ng μL-1), being 10 times more sensitive than nested PCR (1.28 × 10-3 ng μL-1), 100 times more sensitive than real-time PCR (1.28 × 10-2 ng μL-1) and 103 times more sensitive than the conventional PCR assay (1.28 × 10-1 ng μL-1). In the field experiment, the LAMP assay outperformed the other tests by amplifying only diseased tissues (leaf and stem), and showing no positive reaction in healthy tissues. Overall, the LAMP assay developed in this study provides a specific, sensitive, simple, and effective visual method for detection of the P. infestans pathogen, and is therefore suitable for application in early prediction of the disease to reduce the risk of epidemics. PMID:29051751

  5. Multicenter Evaluation of the Cepheid Xpert Methicillin-Resistant Staphylococcus aureus (MRSA) Test as a Rapid Screening Method for Detection of MRSA in Nares▿

    PubMed Central

    Wolk, D. M.; Picton, E.; Johnson, D.; Davis, T.; Pancholi, P.; Ginocchio, C. C.; Finegold, S.; Welch, D. F.; de Boer, M.; Fuller, D.; Solomon, M. C.; Rogers, B.; Mehta, M. S.; Peterson, L. R.

    2009-01-01

    The first U.S. multicenter clinical trial to assess the performance of the Cepheid Xpert MRSA assay (Xpert MRSA) was conducted. The assay is a qualitative test designed for the rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) directly from nares swabs. This novel test combines integrated nucleic acid extraction and automated real-time PCR for the detection of a MRSA-specific signature sequence. A total of 1,077 nares specimens were collected from seven geographically distinct health care sites across the United States with prevalence rates ranging from 5.2% to 44%. Nares specimens were tested by (i) the Xpert MRSA assay, (ii) direct culture on CHROMagar MRSA medium (direct CM culture), and (iii) broth-enriched culture (Trypticase soy broth with 6.5% sodium chloride) followed by plating onto CHROMagar MRSA medium (broth-enriched CM culture). When direct CM culture was designated the reference method, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the Xpert MRSA assay were 94.3%, 93.2%, 73.0%, and 98.8%, respectively. When broth-enriched CM culture was used as the reference method, the clinical sensitivity, specificity, PPV, and NPV of the Xpert MRSA assay were 86.3%, 94.9%, 80.5%, and 96.6%, respectively. The BD GeneOhm MRSA (BDGO) assay was performed as a comparative molecular method. No statistical performance differences were observed between the Xpert MRSA and BDGO assays when they were compared to culture methods. From this large-scale, multicenter clinical comparison, we conclude that the Xpert MRSA assay is a simple, rapid, and accurate method for performing active surveillance for MRSA in a variety of health care populations. PMID:19129414

  6. Loop-mediated isothermal amplification as an emerging technology for detection of Yersinia ruckeri the causative agent of enteric red mouth disease in fish.

    PubMed

    Saleh, Mona; Soliman, Hatem; El-Matbouli, Mansour

    2008-08-12

    Enteric Redmouth (ERM) disease also known as Yersiniosis is a contagious disease affecting salmonids, mainly rainbow trout. The causative agent is the gram-negative bacterium Yersinia ruckeri. The disease can be diagnosed by isolation and identification of the causative agent, or detection of the Pathogen using fluorescent antibody tests, ELISA and PCR assays. These diagnostic methods are laborious, time consuming and need well trained personnel. A loop-mediated isothermal amplification (LAMP) assay was developed and evaluated for detection of Y. ruckeri the etiological agent of enteric red mouth (ERM) disease in salmonids. The assay was optimised to amplify the yruI/yruR gene, which encodes Y. ruckeri quorum sensing system, in the presence of a specific primer set and Bst DNA polymerase at an isothermal temperature of 63 degrees C for one hour. Amplification products were detected by visual inspection, agarose gel electrophoresis and by real-time monitoring of turbidity resulted by formation of LAMP amplicons. Digestion with HphI restriction enzyme demonstrated that the amplified product was unique. The specificity of the assay was verified by the absence of amplification products when tested against related bacteria. The assay had 10-fold higher sensitivity compared with conventional PCR and successfully detected Y. ruckeri not only in pure bacterial culture but also in tissue homogenates of infected fish. The ERM-LAMP assay represents a practical alternative to the microbiological approach for rapid, sensitive and specific detection of Y. ruckeri in fish farms. The assay is carried out in one hour and needs only a heating block or water bath as laboratory furniture. The advantages of the ERM-LAMP assay make it a promising tool for molecular detection of enteric red mouth disease in fish farms.

  7. Diagnostic performance of serological assays for anti-HBs testing: Results from a quality assessment program.

    PubMed

    Raven, Stijn; Hautvast, Jeannine; Steenbergen, Jim van; Akkermans, Reinier; Weykamp, Cas; Smits, Francis; Hoebe, Christian; Vossen, Ann

    2017-02-01

    Post-vaccination testing after hepatitis B vaccination is indispensable to evaluate long-term immunological protection. Using a threshold level of antibodies against hepatitis B surface antigen (anti-HBs) to define serological protection, implies reproducible and valid measurements of different diagnostic assays. In this study we assess the performance of currently used anti-HBs assays. In 2013, 45 laboratories participated in an external quality assessment program using pooled anti-HBs serum samples around the cutoff values 10IU/l and 100IU/l. Laboratories used either Axsym (Abbott Laboratories), Architect (Abbott Laboratories), Access (Beckman-Coulter), ADVIA Centaur anti-HBs2 (Siemens Healthcare Diagnostics), Elecsys, Modular or Cobas (Roche Diagnostics) or Vidas Total Quick (Biomerieux) for anti-HBs titre quantification. We analysed covariance using mixed-model repeated measures. To assess sensitivity/specificity and agreement, a true positive or true negative result was defined as an anti-HBs titre respectively above or below the cutoff value by ≥4 of 6 assays. Different anti-HBs assays were associated with statistically significant (P<0.05) differences in anti-HBs titres in all dilutions. Sensitivity and specificity ranged respectively from 64%-100% and 95%-100%. Agreement between assays around an anti-HBs titre cutoff value of 10IU/l ranged from 93%-100% and was 44% for a cutoff value of 100IU/l. Around a cutoff value of 10IU/l use of the Access assay may result in false-negative results. Concerning the cutoff value of 100IU/l, a sample being classified below or above this cutoff relied heavily on the specific assay used, with both the Architect and the Access resulting in false-negative results. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Evaluation of Different PCR-Based Assays and LAMP Method for Rapid Detection of Phytophthora infestans by Targeting the Ypt1 Gene.

    PubMed

    Khan, Mehran; Li, Benjin; Jiang, Yue; Weng, Qiyong; Chen, Qinghe

    2017-01-01

    Late blight, caused by the oomycete Phytophthora infestans , is one of the most devastating diseases affecting potato and tomato worldwide. Early diagnosis of the P. infestans pathogen causing late blight should be the top priority for addressing disease epidemics and management. In this study, we performed a loop-mediated isothermal amplification (LAMP) assay, conventional polymerase chain reaction (PCR), nested PCR, and real-time PCR to verify and compare the sensitivity and specificity of the reaction based on the Ypt1 (Ras-related protein) gene of P. infestans. In comparison with the PCR-based assays, the LAMP technique led to higher specificity and sensitivity, using uncomplicated equipment with an equivalent time frame. All 43 P. infestans isolates, yielded positive detection results using LAMP assay showing no cross reaction with other Phytophthora spp., oomycetes or fungal pathogens. The LAMP assay yielded the lowest detectable DNA concentration (1.28 × 10 -4 ng μL -1 ), being 10 times more sensitive than nested PCR (1.28 × 10 -3 ng μL -1 ), 100 times more sensitive than real-time PCR (1.28 × 10 -2 ng μL -1 ) and 10 3 times more sensitive than the conventional PCR assay (1.28 × 10 -1 ng μL -1 ). In the field experiment, the LAMP assay outperformed the other tests by amplifying only diseased tissues (leaf and stem), and showing no positive reaction in healthy tissues. Overall, the LAMP assay developed in this study provides a specific, sensitive, simple, and effective visual method for detection of the P. infestans pathogen, and is therefore suitable for application in early prediction of the disease to reduce the risk of epidemics.

  9. Development and Evaluation of a Modified Fourth-Generation Human Immunodeficiency Virus Enzyme Immunoassay for Cross-Sectional Incidence Estimation in Clade B Populations.

    PubMed

    Kirkpatrick, Allison R; Patel, Eshan U; Celum, Connie L; Moore, Richard D; Blankson, Joel N; Mehta, Shruti H; Kirk, Gregory D; Margolick, Joseph B; Quinn, Thomas C; Eshleman, Susan H; Laeyendecker, Oliver

    2016-08-01

    Accurate methods for cross-sectional incidence estimation are needed for HIV surveillance and prevention research. We developed an avidity assay based on the fourth-generation Genetic Systems HIV Combo Ag/Ab EIA (Bio-Rad Combo assay) and evaluated its performance. The Bio-Rad Combo assay was modified incubating samples with and without 0.025 M diethylamine (DEA). The avidity index (AI) was calculated as the ratio of the DEA-treated to untreated result for a specific sample. We analyzed 2,140 samples from 808 individuals from the United States with known duration of HIV infection. The mean duration of recent infection (MDRI) and the false-recent rate (FRR, fraction of samples from individuals known to be infected >2 years misclassified as recent) were calculated for AI cutoffs of 20%-90% for the avidity assay alone and in combination with a viral load assay (VL, limit of detection 400 copies/ml). Factors associated with misclassification of samples collected ≥2 years after infections were also evaluated. The MDRI for the Bio-Rad Combo Avidity assay ranged from 50 days using an AI cutoff of 20% to 276 days using an AI cutoff of 90%; the FRR ranged from 0% to 9%. When samples with a VL <400 copies/ml were classified as nonrecent, the FRRs were reduced approximately twofold and the MDRI estimates were reduced by ∼20%. An AI cutoff of 50% provided an MDRI of 135 days with an FRR of 2.1%. All samples from elite suppressors had an AI >80%. In adjusted analysis, viral suppression and low CD4 cell count were significantly associated with misclassification among individuals infected >2 years. This modified Bio-Rad Combo Avidity assay may be a useful tool for cross-sectional HIV incidence estimation. Further research is needed to evaluate use of this assay in combination with other assays to accurately estimate population-level HIV incidence.

  10. Building predictive in vitro pulmonary toxicity assays using high-throughput imaging and artificial intelligence.

    PubMed

    Lee, Jia-Ying Joey; Miller, James Alastair; Basu, Sreetama; Kee, Ting-Zhen Vanessa; Loo, Lit-Hsin

    2018-06-01

    Human lungs are susceptible to the toxicity induced by soluble xenobiotics. However, the direct cellular effects of many pulmonotoxic chemicals are not always clear, and thus, a general in vitro assay for testing pulmonotoxicity applicable to a wide variety of chemicals is not currently available. Here, we report a study that uses high-throughput imaging and artificial intelligence to build an in vitro pulmonotoxicity assay by automatically comparing and selecting human lung-cell lines and their associated quantitative phenotypic features most predictive of in vivo pulmonotoxicity. This approach is called "High-throughput In vitro Phenotypic Profiling for Toxicity Prediction" (HIPPTox). We found that the resulting assay based on two phenotypic features of a human bronchial epithelial cell line, BEAS-2B, can accurately classify 33 reference chemicals with human pulmonotoxicity information (88.8% balance accuracy, 84.6% sensitivity, and 93.0% specificity). In comparison, the predictivity of a standard cell-viability assay on the same set of chemicals is much lower (77.1% balanced accuracy, 84.6% sensitivity, and 69.5% specificity). We also used the assay to evaluate 17 additional test chemicals with unknown/unclear human pulmonotoxicity, and experimentally confirmed that many of the pulmonotoxic reference and predicted-positive test chemicals induce DNA strand breaks and/or activation of the DNA-damage response (DDR) pathway. Therefore, HIPPTox helps us to uncover these common modes-of-action of pulmonotoxic chemicals. HIPPTox may also be applied to other cell types or models, and accelerate the development of predictive in vitro assays for other cell-type- or organ-specific toxicities.

  11. Performance of an automated solid-phase red cell adherence system compared with that of a manual gel microcolumn assay for the identification of antibodies eluted from red blood cells.

    PubMed

    Finck, R H; Davis, R J; Teng, S; Goldfinger, D; Ziman, A F; Lu, Q; Yuan, S

    2011-01-01

    IgG antibodies coating red blood cells (RBCs) can be removed by elution procedures and their specificity determined by antibody identification studies. Although such testing is traditionally performed using the tube agglutination assay, prior studies have shown that the gel microcolumn (GMC) assay may also be used with comparable results. The purpose of this study was to compare an automated solid-phase red cell adherence (SPRCA) system with a GMC assay for the detection of antibodies eluted from RBCs. Acid eluates from 51 peripheral blood (PB) and 7 cord blood (CB) samples were evaluated by both an automated SPRCA instrument and a manual GMC assay. The concordance rate between the two systems for peripheral RBC samples was 88.2 percent (45 of 51), including cases with alloantibodies (n = 8), warm autoantibodies (n = 12), antibodies with no identifiable specificity (n = 2), and negative results (n = 23). There were six discordant cases, of which four had alloantibodies (including anti-Jka, -E, and -e) demonstrable by the SPRCA system only. In the remaining 2 cases, anti-Fya and antibodies with no identifiable specificity were demonstrable by the GMC assay only. All seven CB specimens produced concordant results, showing anti-A (n = 3), -B (n = 1), maternal anti-Jka (n = 2), or a negative result (n = 1). Automated SPRCA technology has a performance that is comparable with that of a manual GMC assay for identifying antibodies eluted from PB and CB RBCs.

  12. Development of a Cell-Based Functional Assay for the Detection of Clostridium botulinum Neurotoxin Types A and E

    PubMed Central

    Basavanna, Uma; Muruvanda, Tim; Brown, Eric W.; Sharma, Shashi K.

    2013-01-01

    The standard procedure for definitive detection of BoNT-producing Clostridia is a culture method combined with neurotoxin detection using a standard mouse bioassay (MBA). The mouse bioassay is highly sensitive and specific, but it is expensive and time-consuming, and there are ethical concerns due to use of laboratory animals. Cell-based assays provide an alternative to the MBA in screening for BoNT-producing Clostridia. Here, we describe a cell-based assay utilizing a fluorescence reporter construct expressed in a neuronal cell model to study toxin activity in situ. Our data indicates that the assay can detect as little as 100 pM BoNT/A activity within living cells, and the assay is currently being evaluated for the analysis of BoNT in food matrices. Among available in vitro assays, we believe that cell-based assays are widely applicable in high-throughput screenings and have the potential to at least reduce and refine animal assays if not replace it. PMID:23533420

  13. Performance of the new automated Abbott RealTime MTB assay for rapid detection of Mycobacterium tuberculosis complex in respiratory specimens.

    PubMed

    Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C

    2015-09-01

    The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.

  14. Diagnosis of Neisseria gonorrhoeae Using Molecular Beacon

    PubMed Central

    Patel, Achchhe Lal; Sonkar, Subash Chandra; Kumari, Indu; Saluja, Daman

    2015-01-01

    Neisseria gonorrhoeae is an important sexually transmitted diseases (STD) causing pathogen worldwide. Due to absence of an affordable diagnostic assay, routine screening of gonococcal infection becomes impossible in developing countries where infection rates are maximum. Treatment is given on the basis of symptoms alone which leads to spread of infection. Thus, development of a rapid, sensitive, specific, and PCR based visual diagnostic assay suitable for developing countries, required for better disease management, is aimed at in present study. Endocervical swabs were collected from patients visiting gynecology department of various hospitals in Delhi. In-house PCR based assay was developed and modified to visual assay using molecular beacon for end-point detection. It was evaluated against Roche AMPLICOR NG kit and rmp gene. Specificity of beacon was confirmed by competition experiments. Diagnostic test was 98.21% specific and 99.59% sensitive whereas negative and positive predicted value were 99.40% and 98.78%, respectively. We also observed that twice the concentration (2X) of premix was stable at 4°C for 4 months and dry swab samples gave concordant results with that of wet swabs. These features make the test best suitable for routine diagnosis of genital infections in developing countries. PMID:25802857

  15. Development and evaluation of probe based real time loop mediated isothermal amplification for Salmonella: A new tool for DNA quantification.

    PubMed

    Mashooq, Mohmad; Kumar, Deepak; Niranjan, Ankush Kiran; Agarwal, Rajesh Kumar; Rathore, Rajesh

    2016-07-01

    A one step, single tube, accelerated probe based real time loop mediated isothermal amplification (RT LAMP) assay was developed for detecting the invasion gene (InvA) of Salmonella. The probe based RT LAMP is a novel method of gene amplification that amplifies nucleic acid with high specificity and rapidity under isothermal conditions with a set of six primers. The whole procedure is very simple and rapid, and amplification can be obtained in 20min. Detection of gene amplification was accomplished by amplification curve, turbidity and addition of DNA binding dye at the end of the reaction results in colour difference and can be visualized under normal day light and in UV. The sensitivity of developed assay was found 10 fold higher than taqman based qPCR. The specificity of the RT LAMP assay was validated by the absence of any cross reaction with other members of enterobacteriaceae family and other gram negative bacteria. These results indicate that the probe based RT LAMP assay is extremely rapid, cost effective, highly specific and sensitivity and has potential usefulness for rapid Salmonella surveillance. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  16. Evaluation of Xpert MTB/RIF assay performance in the diagnosis of abdominal tuberculosis.

    PubMed

    Kumar, Suraj; Bopanna, Sawan; Kedia, Saurabh; Mouli, Pratap; Dhingra, Rajan; Padhan, Rajesh; Kohli, Mikashmi; Chaubey, Jigyasa; Sharma, Rohini; Das, Prasenjit; Dattagupta, S; Makharia, Govind; Sharma, S K; Ahuja, Vineet

    2017-04-01

    The use of genetic probes for the diagnosis of pulmonary tuberculosis (TB) has been well described. However, the role of these assays in the diagnosis of intestinal tuberculosis is unclear. We therefore assessed the diagnostic utility of the Xpert Mycobacterium tuberculosis /rifampicin (MTB/RIF) assay, and estimated the prevalence of multidrug-resistant (MDR) TB in the Indian population. Of 99 patients recruited, 37 had intestinal TB; two control groups comprised 43 with Crohn's disease (CD) and 19 with irritable bowel syndrome. Colonoscopy was performed before starting any therapy; mucosal biopsies were subjected to histopathology, acid-fast bacilli staining, Lowenstein-Jensen culture, and nucleic acid amplification testing using the Xpert MTB/RIF assay. Patients were followed up for 6 months to confirm the diagnosis and response to therapy. A composite reference standard was used for diagnosis of TB and assessment of the diagnostic utility of the Xpert MTB/RIF assay. Of 37 intestinal TB patients, the Xpert MTB/RIF assay was positive in three of 37 (8.1%), but none had MDR-TB. The sensitivity, specificity, positive predictive value, and negative predictive value of the Xpert MTB/RIF assay was 8.1%, 100%, 100%, and, 64.2%, respectively. The Xpert MTB/RIF assay has low sensitivity but high specificity for intestinal TB, and may be helpful in endemic tuberculosis areas, when clinicians are faced with difficulty differentiating TB and CD. Based on the Xpert MTB/RIF assay, the prevalence of intestinal MDR-TB is low in the Indian population.

  17. Evaluation of a competitive enzyme-linked immunosorbent assay for measurements of soluble HLA-G protein.

    PubMed

    Rasmussen, M; Dahl, M; Buus, S; Djurisic, S; Ohlsson, J; Hviid, T V F

    2014-08-01

    The human leukocyte antigen (HLA) class Ib molecule, HLA-G, has gained increased attention because of its assumed important role in immune regulation. The HLA-G protein exists in several soluble isoforms. Most important are the actively secreted HLA-G5 full-length isoform generated by alternative splicing retaining intron 4 with a premature stop codon, and the cleavage of full-length membrane-bound HLA-G1 from the cell surface, so-called soluble HLA-G1 (sHLA-G1). A specific and sensitive immunoassay for measurements of soluble HLA-G is mandatory for conceivable routine testing and research projects. We report a novel method, a competitive immunoassay, for measuring HLA-G5/sHLA-G1 in biological fluids. The sHLA-G immunoassay is based upon a competitive enzyme-linked immunosorbent assay (ELISA) principle. It includes a recombinant sHLA-G1 protein in complex with β2-microglobulin and a peptide as a standard, biotinylated recombinant sHLA-G1 as an indicator, and the MEM-G/9 anti-HLA-G monoclonal antibody (mAb) as the capture antibody. The specificity and sensitivity of the assay were evaluated. Testing with different recombinant HLA class I proteins and different anti-HLA class I mAbs showed that the sHLA-G immunoassay was highly specific. Optimal combinations of competitor sHLA-G1 and capture mAb concentrations were determined. Two versions of the assay were tested. One with a relatively wide dynamic range from 3.1 to 100.0 ng/ml, and another more sensitive version ranging from 1.6 to 12.5 ng/ml. An intra-assay coefficient of variation (CV) of 15.5% at 88 ng/ml and an inter-assay CV of 23.1% at 39 ng/ml were determined. An assay based on the competitive sHLA-G ELISA may be important for measurements of sHLA-G proteins in several conditions: assisted reproduction, organ transplantation, cancer, and certain pregnancy complications, both in research studies and possibly in the future also for clinical routine use. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Evaluation of the IMMULITE® 2000 CMV IgM assay

    PubMed Central

    2012-01-01

    Background Diagnosis of cytomegalovirus (CMV) infection is challenging because of the high rate of asymptomatic infection and the low specificity of associated symptoms and signs. As a result, laboratory testing is an essential aid in making an accurate diagnosis. The presence of CMV IgM is indicative of primary CMV infection. In pregnancy, diagnosis of primary infection is important because primary maternal infection increases fetal infection risk substantially. Fetal infection can result in serious sequelae ranging from neurological deficits to death. Diagnosis among the immunocompromised is also critical for the timely initiation of therapy that can reduce morbidity and mortality risk. Methods The IMMULITE® 2000 CMV IgM assay qualitatively detects CMV IgM antibodies in human serum or plasma to aid in the diagnosis of current or recent CMV infection. To determine expected values in apparently healthy subjects, 136 samples were tested. Reproducibility, normal range, and method comparison studies were also performed to evaluate the assay's performance. The assay's reproducibility was evaluated across three sites. Seven hundred and eighteen (n = 718) individual patient serum samples, which included samples from CMV IgM-positive (n = 109, determined by the Abbott IMx CMV or the Diamedix CMV IgM assays), pregnant (n = 210), HIV-positive (n = 30), immunosuppressed (n = 102), and transplant patients (n = 17) and from patients with potentially cross-reacting conditions (n = 136) were evaluated in the method comparison study. The positive, negative, and overall agreement between the IMMULITE 2000 CMV IgM assay and the VIDAS CMV IgM assay (predicate assay) were determined. Results The assay demonstrated excellent reproducibility with a total CV of less than 10%. The positive, negative, and overall agreement between the IMMULITE 2000 assay and the VIDAS assay were > 95% for the method comparison samples. Among potentially cross-reactive samples, the overall agreement between the two assays was 96%. Similarly, among the immunocompromised and pregnant subjects, the overall agreement was ~96% and ~97%, respectively. Conclusions The IMMULITE 2000 CMV IgM assay demonstrated excellent reproducibility, minimal cross-reactivity, and performance comparable to that of the VIDAS CMV IgM assay. It can aid in the diagnosis of acute CMV or recent CMV infection by qualitatively detecting the CMV IgM antibodies in human serum or plasma. PMID:22377002

  19. Evaluation of the IMMULITE® 2000 CMV IgM assay.

    PubMed

    Bal, Tricia A; Armstrong, Glenn; Han, Xiang Y

    2012-02-29

    Diagnosis of cytomegalovirus (CMV) infection is challenging because of the high rate of asymptomatic infection and the low specificity of associated symptoms and signs. As a result, laboratory testing is an essential aid in making an accurate diagnosis. The presence of CMV IgM is indicative of primary CMV infection. In pregnancy, diagnosis of primary infection is important because primary maternal infection increases fetal infection risk substantially. Fetal infection can result in serious sequelae ranging from neurological deficits to death. Diagnosis among the immunocompromised is also critical for the timely initiation of therapy that can reduce morbidity and mortality risk. The IMMULITE® 2000 CMV IgM assay qualitatively detects CMV IgM antibodies in human serum or plasma to aid in the diagnosis of current or recent CMV infection. To determine expected values in apparently healthy subjects, 136 samples were tested. Reproducibility, normal range, and method comparison studies were also performed to evaluate the assay's performance. The assay's reproducibility was evaluated across three sites. Seven hundred and eighteen (n = 718) individual patient serum samples, which included samples from CMV IgM-positive (n = 109, determined by the Abbott IMx CMV or the Diamedix CMV IgM assays), pregnant (n = 210), HIV-positive (n = 30), immunosuppressed (n = 102), and transplant patients (n = 17) and from patients with potentially cross-reacting conditions (n = 136) were evaluated in the method comparison study. The positive, negative, and overall agreement between the IMMULITE 2000 CMV IgM assay and the VIDAS CMV IgM assay (predicate assay) were determined. The assay demonstrated excellent reproducibility with a total CV of less than 10%. The positive, negative, and overall agreement between the IMMULITE 2000 assay and the VIDAS assay were > 95% for the method comparison samples. Among potentially cross-reactive samples, the overall agreement between the two assays was 96%. Similarly, among the immunocompromised and pregnant subjects, the overall agreement was ~96% and ~97%, respectively. The IMMULITE 2000 CMV IgM assay demonstrated excellent reproducibility, minimal cross-reactivity, and performance comparable to that of the VIDAS CMV IgM assay. It can aid in the diagnosis of acute CMV or recent CMV infection by qualitatively detecting the CMV IgM antibodies in human serum or plasma.

  20. Building Structure Feature-based Models for Predicting Isoform-specific Human Cytochrome P-450 (hCYP 3A4, 2D6 and 2C9) Inhibition Assay Results in ToxCast

    EPA Science Inventory

    EPA’s ToxCast project is using high-throughput screening (HTS) to profile and prioritize chemicals for further testing. ToxCast Phase I evaluated 309 unique chemicals, the majority pesticide actives, in over 500 HTS assays. These included 3 human cytochrome P450 (hCYP3A4, hCYP2...

  1. Folate and Breast Cancer: Role of Intake, Blood Levels, and Metabolic Gene Polymorphisms

    DTIC Science & Technology

    2006-06-01

    polymorphisms . The specific aims are 1) methodological training in the analysis of gene - gene and gene -environment interactions by studying folate...evaluation of folate intake, plasma folate, and metabolic gene polymorphisms in relation to breast cancer risk: Months 1-19. b. Prepare blood samples...isolated for the folate and gene polymorphism assays among the 184 cases and matched controls. The folate assays are on-going at this time and over

  2. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis

    PubMed Central

    Urabe, Naohisa; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-01-01

    ABSTRACT We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. PMID:28330887

  3. Complement dependent cytotoxicity (CDC) activity of a humanized anti Lewis-Y antibody: FACS-based assay versus the 'classical' radioactive method -- qualification, comparison and application of the FACS-based approach.

    PubMed

    Nechansky, A; Szolar, O H J; Siegl, P; Zinoecker, I; Halanek, N; Wiederkum, S; Kircheis, R

    2009-05-01

    The fully humanized Lewis-Y carbohydrate specific monoclonal antibody (mAb) IGN311 is currently tested in a passive immunotherapy approach in a clinical phase I trail and therefore regulatory requirements demand qualified assays for product analysis. To demonstrate the functionality of its Fc-region, the capacity of IGN311 to mediate complement dependent cytotoxicity (CDC) against human breast cancer cells was evaluated. The "classical" radioactive method using chromium-51 and a FACS-based assay were established and qualified according to ICH guidelines. Parameters evaluated were specificity, response function, bias, repeatability (intra-day precision), intermediate precision (operator-time different), and linearity (assay range). In the course of a fully nested design, a four-parameter logistic equation was identified as appropriate calibration model for both methods. For the radioactive assay, the bias ranged from -6.1% to -3.6%. The intermediate precision for future means of duplicate measurements revealed values from 12.5% to 15.9% and the total error (beta-expectation tolerance interval) of the method was found to be <40%. For the FACS-based assay, the bias ranged from -8.3% to 0.6% and the intermediate precision for future means of duplicate measurements revealed values from 4.2% to 8.0%. The total error of the method was found to be <25%. The presented data demonstrate that the FACS-based CDC is more accurate than the radioactive assay. Also, the elimination of radioactivity and the 'real-time' counting of apoptotic cells further justifies the implementation of this method which was subsequently applied for testing the influence of storage at 4 degrees C and 25 degrees C ('stability testing') on the potency of IGN311 drug product. The obtained results demonstrate that the qualified functional assay represents a stability indicating test method.

  4. Enzyme-linked immunosorbent assay compared with neutralization tests for evaluation of live mumps vaccines.

    PubMed Central

    Sakata, H; Hishiyama, M; Sugiura, A

    1984-01-01

    Mumps-specific antibody levels before and after vaccination with live mumps vaccines were determined by enzyme-linked immunosorbent assay (ELISA) and neutralization tests. A correlation was found between neutralization titers and optical density in ELISA. However, postvaccination sera from some vaccinees who failed to seroconvert by neutralization contained significant levels of mumps-specific antibody detectable by ELISA. In some of these serum specimens, the antibody directed to the F polypeptide of mumps virus was predominant. Most sera positive in ELISA neutralized mumps virus upon the addition of fresh guinea pig serum to the virus-serum mixture. Images PMID:6361060

  5. Development and validation of four one-step real-time RT-LAMP assays for specific detection of each dengue virus serotype

    PubMed Central

    Bekaert, Michaël; Bakheit, Mohammed; Frischmann, Sieghard; Patel, Pranav; Simon-Loriere, Etienne; Lambrechts, Louis; Duong, Veasna; Dussart, Philippe; Harold, Graham; Fall, Cheikh; Faye, Oumar; Sall, Amadou Alpha; Weidmann, Manfred

    2018-01-01

    Background 4 one-step, real-time, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays were developed for the detection of dengue virus (DENV) serotypes by considering 2,056 full genome DENV sequences. DENV1 and DENV2 RT-LAMP assays were validated with 31 blood and 11 serum samples from Tanzania, Senegal, Sudan and Mauritania. DENV3 and DENV4 RT-LAMP assays were validated with 25 serum samples from Cambodia Methodology/Principal findings 4 final reaction primer mixes were obtained by using a combination of Principal Component Analysis of the full DENV genome sequences, and LAMP primer design based on sequence alignments using the LAVA software. These mixes contained 14 (DENV1), 12 (DENV2), 8 (DENV3) and 3 (DENV4) LAMP primer sets. The assays were evaluated with an External Quality Assessment panel from Quality Control for Molecular Diagnostics. The assays were serotype-specific and did not cross-detect with other flaviviruses. The limits of detection, with 95% probability, were 22 (DENV1), 542 (DENV2), 197 (DENV3) and 641 (DENV4) RNA molecules, and 100% reproducibility in the assays was obtained with up to 102 (DENV1) and 103 RNA molecules (DENV2, DENV3 and DENV4). Validation of the DENV2 assay with blood samples from Tanzania resulted in 23 samples detected by RT-LAMP, demonstrating that the assay is 100% specific and 95.8% sensitive (positive predictive value of 100% and a negative predictive value of 85.7%). All serum samples from Senegal, Sudan and Mauritania were detected and 3 untyped as DENV1. The sensitivity of RT-LAMP for DENV4 samples from Cambodia did not quite match qRT-PCR. Conclusions/Significance We have shown a novel approach to design LAMP primers that makes use of fast growing sequence databases. The DENV1 and DENV2 assays were validated with viral RNA extracted clinical samples, showing very good performance parameters. PMID:29813062

  6. Evaluation of ELISA tests specific for Shiga toxin 1 and 2 in food and water samples

    USDA-ARS?s Scientific Manuscript database

    Two enzyme-linked immunosorbent assay (ELISA) kits were evaluated for their effectiveness in detecting and differentiating between Shiga toxin 1 and 2 (Stx1 and Stx2) produced by Shiga toxin-producing E. coli (STEC) inoculated into food and water samples. Each kit incorporated monoclonal antibodies ...

  7. Utilizing Low-Volume Aqueous Acoustic Transfer with the Echo 525 to Enable Miniaturization of qRT-PCR Assay.

    PubMed

    Agrawal, Sony; Cifelli, Steven; Johnstone, Richard; Pechter, David; Barbey, Deborah A; Lin, Karen; Allison, Tim; Agrawal, Shree; Rivera-Gines, Aida; Milligan, James A; Schneeweis, Jonathan; Houle, Kevin; Struck, Alice J; Visconti, Richard; Sills, Matthew; Wildey, Mary Jo

    2016-02-01

    Quantitative reverse transcription PCR (qRT-PCR) is a valuable tool for characterizing the effects of inhibitors on viral replication. The amplification of target viral genes through the use of specifically designed fluorescent probes and primers provides a reliable method for quantifying RNA. Due to reagent costs, use of these assays for compound evaluation is limited. Until recently, the inability to accurately dispense low volumes of qRT-PCR assay reagents precluded the routine use of this PCR assay for compound evaluation in drug discovery. Acoustic dispensing has become an integral part of drug discovery during the past decade; however, acoustic transfer of microliter volumes of aqueous reagents was time consuming. The Labcyte Echo 525 liquid handler was designed to enable rapid aqueous transfers. We compared the accuracy and precision of a qPCR assay using the Labcyte Echo 525 to those of the BioMek FX, a traditional liquid handler, with the goal of reducing the volume and cost of the assay. The data show that the Echo 525 provides higher accuracy and precision compared to the current process using a traditional liquid handler. Comparable data for assay volumes from 500 nL to 12 µL allowed the miniaturization of the assay, resulting in significant cost savings of drug discovery and process streamlining. © 2015 Society for Laboratory Automation and Screening.

  8. Affordable in-house antiretroviral drug resistance assay with good performance in non-subtype B HIV-1

    PubMed Central

    Wallis, Carole L.; Papathanasopoulos, Maria A.; Lakhi, Shabir; Karita, Etienne; Kamali, Anatoli; Kaleebu, Pontiano; Sanders, Eduard; Anzala, Omu; Bekker, Linda-Gail; Stevens, Gwynn; Rinke de Wit, Tobias F.; Stevens, Wendy

    2010-01-01

    The introduction of antiretroviral therapy in resource-poor settings is effective in suppressing HIV-1 replication and prolonging life of infected individuals. This has led to a demand for affordable HIV-1 drug resistance assays, since treatment failure due to development of drug resistance is common. This study developed and evaluated an affordable “in–house” genotyping assay to monitor HIV-1 drug resistance in Africa, particularly South Africa. An “in-house” assay using automated RNA extraction, and subtype C specific PCR and sequencing primers was developed and successfully evaluated 396 patient samples (viral load ranges 1,000->1.6million RNA copies/ml). The “in-house” assay was validated by comparing sequence data and drug resistance profiles from 90 patient and 10 external quality control samples to data from the ViroSeqTM HIV-1 Genotyping kit. The “in-house” assay was more efficient, amplifying all 100 samples, compared to 91 samples using Viroseq. The “in house” sequences were 99.2%) homologous to the ViroSeq sequences, and identical drug resistance mutation profiles were observed in 96 samples. Furthermore, the “in-house” assay genotyped 260 of 295 samples from seven African sites, where 47% were non-subtype C. Overall, the newly validated “in-house” drug resistance assay is suited for use in Africa as it overcomes the obstacle of subtype diversity. PMID:19917318

  9. Affordable in-house antiretroviral drug resistance assay with good performance in non-subtype B HIV-1.

    PubMed

    Wallis, Carole L; Papathanasopoulos, Maria A; Lakhi, Shabir; Karita, Etienne; Kamali, Anatoli; Kaleebu, Pontiano; Sanders, Eduard; Anzala, Omu; Bekker, Linda-Gail; Stevens, Gwynn; de Wit, Tobias F Rinke; Stevens, Wendy

    2010-02-01

    The introduction of antiretroviral (ARV) therapy in resource-poor settings is effective in suppressing HIV-1 replication and prolonging life of infected individuals. This has led to a demand for affordable HIV-1 drug resistance assays, since treatment failure due to development of drug resistance is common. This study developed and evaluated an affordable "in-house" genotyping assay to monitor HIV-1 drug resistance in Africa, particularly South Africa. An "in-house" assay using automated RNA extraction, and subtype C specific PCR and sequencing primers was developed and successfully evaluated 396 patient samples (viral load ranges 1000-1.6 million RNA copies/ml). The "in-house" assay was validated by comparing sequence data and drug resistance profiles from 90 patient and 10 external quality control samples to data from the ViroSeq HIV-1 Genotyping kit. The "in-house" assay was more efficient, amplifying all 100 samples, compared to 91 samples using Viroseq. The "in house" sequences were 99.2% homologous to the ViroSeq sequences, and identical drug resistance mutation profiles were observed in 96 samples. Furthermore, the "in-house" assay genotyped 260 of 295 samples from seven African sites, where 47% were non-subtype C. Overall, the newly validated "in-house" drug resistance assay is suited for use in Africa as it overcomes the obstacle of subtype diversity. 2009 Elsevier B.V. All rights reserved.

  10. Development and evaluation of antibody-capture immunoassays for detection of Lassa virus nucleoprotein-specific immunoglobulin M and G

    PubMed Central

    Gabriel, Martin; Adomeh, Donatus I.; Ehimuan, Jacqueline; Oyakhilome, Jennifer; Omomoh, Emmanuel O.; Ighodalo, Yemisi; Olokor, Thomas; Bonney, Kofi; Pahlmann, Meike; Emmerich, Petra; Lelke, Michaela; Brunotte, Linda; Ölschläger, Stephan; Thomé-Bolduan, Corinna; Becker-Ziaja, Beate; Busch, Carola; Odia, Ikponmwosa; Ogbaini-Emovon, Ephraim; Okokhere, Peter O.; Okogbenin, Sylvanus A.; Akpede, George O.; Schmitz, Herbert; Asogun, Danny A.

    2018-01-01

    Background The classical method for detection of Lassa virus-specific antibodies is the immunofluorescence assay (IFA) using virus-infected cells as antigen. However, IFA requires laboratories of biosafety level 4 for assay production and an experienced investigator to interpret the fluorescence signals. Therefore, we aimed to establish and evaluate enzyme-linked immunosorbent assays (ELISA) using recombinant Lassa virus nucleoprotein (NP) as antigen. Methodology/Principal findings The IgM ELISA is based on capturing IgM antibodies using anti-IgM, and the IgG ELISA is based on capturing IgG antibody–antigen complexes using rheumatoid factor or Fc gamma receptor CD32a. Analytical and clinical evaluation was performed with 880 sera from Lassa fever endemic (Nigeria) and non-endemic (Ghana and Germany) areas. Using the IFA as reference method, we observed 91.5–94.3% analytical accuracy of the ELISAs in detecting Lassa virus-specific antibodies. Evaluation of the ELISAs for diagnosis of Lassa fever on admission to hospital in an endemic area revealed a clinical sensitivity for the stand-alone IgM ELISA of 31% (95% CI 25–37) and for combined IgM/IgG detection of 26% (95% CI 21–32) compared to RT-PCR. The specificity of IgM and IgG ELISA was estimated at 96% (95% CI 93–98) and 100% (95% CI 99–100), respectively, in non-Lassa fever patients from non-endemic areas. In patients who seroconverted during follow-up, Lassa virus-specific IgM and IgG developed simultaneously rather than sequentially. Consistent with this finding, isolated IgM reactivity, i.e. IgM in the absence of IgG, had no diagnostic value. Conclusions/Significance The ELISAs are not equivalent to RT-PCR for early diagnosis of Lassa fever; however, they are of value in diagnosing patients at later stage. The IgG ELISA may be useful for epidemiological studies and clinical trials due its high specificity, and the higher throughput rate and easier operation compared to IFA. PMID:29596412

  11. Development and evaluation of a new lateral flow assay for simultaneous detection of antibodies against African Horse Sickness and Equine Infectious Anemia viruses.

    PubMed

    Costa, Sofia; Sastre, Patricia; Pérez, Teresa; Tapia, Istar; Barrandeguy, María; Sánchez-Vizcaíno, José M; Sánchez-Matamoros, Almudena; Wigdorovitz, Andrés; Sanz, Antonio; Rueda, Paloma

    2016-11-01

    African horse sickness (AHS) and equine infectious anemia (EIA) are both notifiable equid specific diseases that may present similar clinical signs. Considering the increased global movement of horses and equine products over the past decades, together with the socio-economic impact of previous AHS and EIA outbreaks, there is a clear demand for an early discrimination and a strict control of their transmission between enzootic and AHS/EIA-free regions. Currently, the individual control and prevention of AHS or EIA relies on a series of measures, including the restriction of animal movements, vector control, and the use of several laboratory techniques for viral identification, amongst others. Despite being widely employed in surveillance programmes and in the control of animal movements, the available serological assays can only detect AHS- or EIA-specific antibodies individually. In this work, a duplex lateral flow assay (LFA) for simultaneous detection and differentiation of specific antibodies against AHS virus (AHSV) and EIA virus (EIAV) was developed and evaluated with experimental and field serum samples. The duplex LFA was based on the AHSV-VP7 outer core protein and the EIAV-P26 major core protein. The results indicated that the duplex LFA presented a good analytical performance, detecting simultaneously and specifically antibodies against AHSV and EIAV. The initial diagnostic evaluation revealed a good agreement with results from the AHS and EIA tests prescribed by the OIE, and it highlighted the usefulness of the new AHSV/EIAV duplex LFA for an on-field and point-of-care first diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Forensic interlaboratory evaluation of the ForFLUID kit for vaginal fluids identification.

    PubMed

    Giampaoli, Saverio; Alessandrini, Federica; Berti, Andrea; Ripani, Luigi; Choi, Ajin; Crab, Roselien; De Vittori, Elisabetta; Egyed, Balazs; Haas, Cordula; Lee, Hwan Young; Korabecná, Marie; Noel, Fabrice; Podini, Daniele; Tagliabracci, Adriano; Valentini, Alessio; Romano Spica, Vincenzo

    2014-01-01

    Identification of vaginal fluids is an important step in the process of sexual assaults confirmation. Advances in both microbiology and molecular biology defined technical approaches allowing the discrimination of body fluids. These protocols are based on the identification of specific bacterial communities by microfloraDNA (mfDNA) amplification. A multiplex real time-PCR assay (ForFLUID kit) has been developed for identifying biological fluids and for discrimination among vaginal, oral and fecal samples. In order to test its efficacy and reliability of the assay in the identification of vaginal fluids, an interlaboratory evaluation has been performed on homogeneous vaginal swabs. All the involved laboratories were able to correctly recognize all the vaginal swabs, and no false positives were identified when the assay was applied on non-vaginal samples. The assay represents an useful molecular tool that can be easily adopted by forensic geneticists involved in vaginal fluid identification. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  13. Development of a highly sensitive real-time nested RT-PCR assay in a single closed tube for detection of enterovirus 71 in hand, foot, and mouth disease.

    PubMed

    Niu, Peihua; Qi, Shunxiang; Yu, Benzhang; Zhang, Chen; Wang, Ji; Li, Qi; Ma, Xuejun

    2016-11-01

    Enterovirus 71 (EV71) is one of the major causative agents of outbreaks of hand, foot, and mouth disease (HFMD). A commercial TaqMan probe-based real-time PCR assay has been widely used for the differential detection of EV71 despite its relatively high cost and failure to detect samples with a low viral load (Ct value > 35). In this study, a highly sensitive real-time nested RT-PCR (RTN RT-PCR) assay in a single closed tube for detection of EV71 in HFMD was developed. The sensitivity and specificity of this assay were evaluated using a reference EV71 stock and a panel of controls consisting of coxsackievirus A16 (CVA16) and common respiratory viruses, respectively. The clinical performance of this assay was evaluated and compared with those of a commercial TaqMan probe-based real-time PCR (qRT-PCR) assay and a traditional two-step nested RT-PCR assay. The limit of detection for the RTN RT-PCR assay was 0.01 TCID50/ml, with a Ct value of 38.3, which was the same as that of the traditional two-step nested RT-PCR assay and approximately tenfold lower than that of the qRT-PCR assay. When testing the reference strain EV71, this assay showed favorable detection reproducibility and no obvious cross-reactivity. The testing results of 100 clinical throat swabs from HFMD-suspected patients revealed that 41 samples were positive for EV71 by both RTN RT-PCR and traditional two-step nested RT-PCR assays, whereas only 29 were EV71 positive by qRT-PCR assay.

  14. Characterization and Comparison of Galactomannan Enzyme Immunoassay and Quantitative Real-Time PCR Assay for Detection of Aspergillus fumigatus in Bronchoalveolar Lavage Fluid from Experimental Invasive Pulmonary Aspergillosis

    PubMed Central

    Francesconi, Andrea; Kasai, Miki; Petraitiene, Ruta; Petraitis, Vidmantas; Kelaher, Amy M.; Schaufele, Robert; Hope, William W.; Shea, Yvonne R.; Bacher, John; Walsh, Thomas J.

    2006-01-01

    Bronchoalveolar lavage (BAL) is widely used for evaluation of patients with suspected invasive pulmonary aspergillosis (IPA). However, the diagnostic yield of BAL for detection of IPA by culture and direct examination is limited. Earlier diagnosis may be facilitated by assays that can detect Aspergillus galactomannan antigen or DNA in BAL fluid. We therefore characterized and compared the diagnostic yields of a galactomannan enzyme immunoassay (GM EIA), quantitative real-time PCR (qPCR), and quantitative cultures in experiments using BAL fluid from neutropenic rabbits with experimentally induced IPA defined as microbiologically and histologically evident invasion. The qPCR assay targeted the rRNA gene complex of Aspergillus fumigatus. The GM EIA and qPCR assay were characterized by receiver operator curve analysis. With an optimal cutoff of 0.75, the GM EIA had a sensitivity and specificity of 100% in untreated controls. A decline in sensitivity (92%) was observed when antifungal therapy (AFT) was administered. The optimal cutoff for qPCR was a crossover of 36 cycles, with sensitivity and specificity of 80% and 100%, respectively. The sensitivity of qPCR also decreased with AFT to 50%. Quantitative culture of BAL had a sensitivity of 46% and a specificity of 100%. The sensitivity of quantitative culture decreased with AFT to 16%. The GM EIA and qPCR assay had greater sensitivity than culture in detection of A. fumigatus in BAL fluid in experimentally induced IPA (P ± 0.04). Use of the GM EIA and qPCR assay in conjunction with culture-based diagnostic methods applied to BAL fluid could facilitate accurate diagnosis and more-timely initiation of specific therapy. PMID:16825367

  15. Development and evaluation of a real-time RT-PCR assay for detection of a novel avian influenza A (H5N6) virus.

    PubMed

    Zhang, Rusheng; Yao, Dong; Chen, Jingfang; Ye, Wen; Ou, Xinhua; Chen, Tianmu; Sun, Biancheng

    2018-07-01

    As of Aug 25, 2017, 17 incidences of human infection and 6 deaths due to the novel H5N6 virus have been reported in China. Genetic analysis of the viral genome revealed that this reassortant virus is highly pathogenic to poultry, and that the virus has a risk of transmission to humans. Accordingly, the development of a rapid, sensitive, and specific molecular diagnostic assay is critical for public health. In this study, a real-time reverse-transcription PCR (RT-PCR) assay was developed to specifically detect the novel H5N6 virus, with primer pairs targeting the hemagglutinin and neuraminidase gene sequences of this virus. RNA was extracted from throat swab specimens from patients with influenza-like illness (ILIs), and environmental samples were collected from live poultry markets (LPMs) for H5N6 virus detection by real-time RT-PCR. The method was demonstrated to enable specific detection of the avian H5N6 virus, with no cross-reactivity with seasonal influenza viruses (H1N1, H1N1 pdm09, H3N2 or B); H5N1, H7N9, H9N2 viruses; or other human respiratory viruses. The detection limit of the assay was 1.0 × 10 1 copies per reaction for N6 and 1.0 × 10 2 copies per reaction for H5 assays. The assay is a powerful tool for rapid, sensitive, and specific detection of H5N6 virus infection in specimens derived from humans, animals, and the environment. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Development of a single-antigen magnetic bead assay (SAMBA) for the sensitive detection of HPA-1a alloantibodies using tag-engineered recombinant soluble β3 integrin.

    PubMed

    Skaik, Younis; Battermann, Anja; Hiller, Oliver; Meyer, Oliver; Figueiredo, Constanca; Salama, Abdulgabar; Blasczyk, Rainer

    2013-05-31

    Timely and accurate testing for human platelet antigen 1a (HPA-1a) alloantibodies is vital for clinical diagnosis of neonatal alloimmune thrombocytopenia (NAIT). Current antigen-specific assays used for the detection of HPA-1 alloantibodies are technically very complex and cumbersome for most diagnostic laboratories. Hence, we designed and applied recombinant soluble (rs) β3 integrins displaying HPA-1a or HPA-1b epitopes for the development of a single-antigen magnetic bead assay (SAMBA). Soluble HPA-1a and HPA-1b were produced recombinantly in human embryonic kidney 293 (HEK293) cells and differentially tagged. The recombinant soluble proteins were then immobilized onto paramagnetic beads and used for analysis of HPA-1 alloantibodies by enzyme-linked immunosorbent assay (ELISA). HPA-1a serum samples (n=7) from NAIT patients, inert sera and sera containing non-HPA-1a antibodies were used to evaluate the sensitivity and specificity of the SAMBA. Fusion of V5-His or GS-SBP-His tags to the rsβ3 integrins resulted in high-yield expression. SAMBA was able to detect all HPA-1a and -1b alloantibodies recognized by monoclonal antibody-specific immobilization of platelet antigens assay (MAIPA). No cross-reactions between the sera were observed. Two out of seven of the HPA-1a alloantibody-containing sera demonstrated weak to moderate reactivity in MAIPA but strong signals in SAMBA. SAMBA provides a very reliable method for the detection of HPA-1 antibodies with high specificity and sensitivity. This simple and rapid assay can be adapted for use in any routine laboratory and can be potentially adapted for use on automated systems. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Evaluation of multiplex tandem real-time PCR for detection of Cryptosporidium spp., Dientamoeba fragilis, Entamoeba histolytica, and Giardia intestinalis in clinical stool samples.

    PubMed

    Stark, D; Al-Qassab, S E; Barratt, J L N; Stanley, K; Roberts, T; Marriott, D; Harkness, J; Ellis, J T

    2011-01-01

    The aim of this study was to describe the first development and evaluation of a multiplex tandem PCR (MT-PCR) assay for the detection and identification of 4 common pathogenic protozoan parasites, Cryptosporidium spp., Dientamoeba fragilis, Entamoeba histolytica, and Giardia intestinalis, from human clinical samples. A total of 472 fecal samples submitted to the Department of Microbiology at St. Vincent's Hospital were included in the study. The MT-PCR assay was compared to four real-time PCR (RT-PCR) assays and microscopy by a traditional modified iron hematoxylin stain. The MT-PCR detected 28 G. intestinalis, 26 D. fragilis, 11 E. histolytica, and 9 Cryptosporidium sp. isolates. Detection and identification of the fecal protozoa by MT-PCR demonstrated 100% correlation with the RT-PCR results, and compared to RT-PCR, MT-PCR exhibited 100% sensitivity and specificity, while traditional microscopy of stained fixed fecal smears exhibited sensitivities and specificities of 56% and 100% for Cryptosporidium spp., 38% and 99% for D. fragilis, 47% and 97% for E. histolytica, and 50% and 100% for G. intestinalis. No cross-reactivity was detected in 100 stool samples containing various other bacterial, viral, and protozoan species. The MT-PCR assay was able to provide rapid, sensitive, and specific simultaneous detection and identification of the four most important diarrhea-causing protozoan parasites that infect humans. This study also highlights the lack of sensitivity demonstrated by microscopy, and thus, molecular methods such as MT-PCR must be considered the diagnostic methods of choice for enteric protozoan parasites.

  18. Evaluation of a New IFN-γ Release Assay for Rapid Diagnosis of Active Tuberculosis in a High-Incidence Setting.

    PubMed

    Li, Gen; Li, Feng; Zhao, Hui-Min; Wen, Han-Li; Li, Hai-Cong; Li, Chun-Ling; Ji, Ping; Xu, Peng; Wu, Kang; Hu, Zhi-Dong; Lu, Shui-Hua; Lowrie, Douglas B; Lv, Jian-Xin; Fan, Xiao-Yong

    2017-01-01

    Blood-based interferon-gamma (IFN-γ) release assays (IGRAs) have been proven to be useful in the diagnosis of Mycobacterium tuberculosis ( Mtb ) infection. However, IGRAs have not been recommended for clinical practice in most low-income settings due to cost-intensive limitations and shortage of clinical data available. The established T-SPOT. TB assay containing Mtb -specific antigens ESAT-6 and CFP10 are widely used for immunodiagonsis of Mtb infection, but the high cost is one of the restricting factors against its clinical application in the developing countries. More recently, a cost-saving IGRA assay, TS-SPOT, was approved in China. This new assay contains an additional antigen Rv3615c. Rv3615c contains broadly recognized CD4 + and CD8 + epitopes, and T-cell responses to Rv3615c are as specific for Mtb infection as the responses to ESAT-6 and CFP10 in both Mtb -infected humans and M. bovis -infected cattle. Therefore, we assessed the likely effect of inclusion of Rv3615c as stimulus besides ESAT-6 and CFP10 in an IGRA assay and evaluated the performance of TS-SPOT for diagnosis of Mtb infection and active TB compared with T-SPOT. TB . We tested 155 active TB patients, 90 non-TB lung disease patients, and 55 healthy individuals. The results presented an improved positive rate for diagnosis of active TB and Mtb infection, that could be attributable to inclusion of Rv3615c in the mixture of stimulatory antigens. The diagnostic efficiency of TS-SPOT assay for active TB was as follows: sensitivity 80.00%, specificity 83.45%, positive predictive value (PPV) 83.78%, negative predictive value (NPV) 83.45%, positive likelihood ratio (LR+) 4.83, and negative likelihood ratio (LR-) 0.24. The results were similar to those of T-SPOT. TB , with an excellent agreement (κ = 0.91, 95% CI: 0.85-0.95) being observed between these two assays. The sensitivities of the TS-SPOT assay varied for patients with different forms of active TB, with the highest sensitivity for patients with culture-positive pulmonary TB (92.16%) and the lowest for those with tuberculosis meningitis (50.00%). Taken together, the current evidence indicates that this new TS-SPOT assay is a useful adjunct to the current tests for rapid diagnosis of active TB and Mtb infection in low-income and high-incidence settings due to its characteristics of cost-effectiveness and high-quality.

  19. Development and Evaluation of a Sensitive and Specific Assay for Diagnosis of Human Toxocariasis by Use of Three Recombinant Antigens (TES-26, TES-30USM, and TES-120)▿

    PubMed Central

    Mohamad, Suharni; Azmi, Norhaida Che; Noordin, Rahmah

    2009-01-01

    Diagnosis of human toxocariasis currently relies on serologic tests that use Toxocara excretory-secretory (TES) antigen to detect immunoglobulin G (IgG) antibodies to the larvae. In general, however, these assays do not have adequate specificity for use in countries in which other soil-transmitted helminths are endemic. The use of recombinant antigens in these assays, however, is promising for improving the specificity of the diagnosis of toxocariasis. Toward this goal, we developed an IgG4 enzyme-linked immunosorbent assay (ELISA) involving three recombinant antigens: rTES-30USM (previously produced), rTES-26, and rTES-120. The latter two antigens were produced by reverse transcription-PCR cloning; subcloned into glutathione S-transferase (GST)-tagged and His-tagged prokaryotic expression vectors, respectively; and expressed in Escherichia coli. The recombinant proteins were subsequently purified by affinity chromatography using GST and His-Trap resins. The diagnostic potential of each purified recombinant antigen was tested with various immunoglobulin classes (IgG, IgM, and IgE) and IgG subclasses. The IgG4 ELISA was determined to have the highest specificity and was further evaluated using a panel of serum samples. The rTES-26 IgG4 ELISA showed 80.0% (24/30 samples positive) sensitivity, and both the rTES-30USM IgG4 ELISA and rTES-120 IgG4 ELISA had 93.0% (28/30) sensitivity. Combined use of rTES-120 and rTES-30 IgG4 ELISA for the diagnosis of toxocariasis provided 100% sensitivity. The specificities of rTES-26, rTES-30USM, and rTES-120 antigens were 96.2%, 93.9%, and 92.0%, respectively. These results indicate that the development of a diagnostic test using the three recombinant antigens will allow for more-accurate detection of toxocariasis. PMID:19369434

  20. Development and evaluation of a sensitive and specific assay for diagnosis of human toxocariasis by use of three recombinant antigens (TES-26, TES-30USM, and TES-120).

    PubMed

    Mohamad, Suharni; Azmi, Norhaida Che; Noordin, Rahmah

    2009-06-01

    Diagnosis of human toxocariasis currently relies on serologic tests that use Toxocara excretory-secretory (TES) antigen to detect immunoglobulin G (IgG) antibodies to the larvae. In general, however, these assays do not have adequate specificity for use in countries in which other soil-transmitted helminths are endemic. The use of recombinant antigens in these assays, however, is promising for improving the specificity of the diagnosis of toxocariasis. Toward this goal, we developed an IgG4 enzyme-linked immunosorbent assay (ELISA) involving three recombinant antigens: rTES-30USM (previously produced), rTES-26, and rTES-120. The latter two antigens were produced by reverse transcription-PCR cloning; subcloned into glutathione S-transferase (GST)-tagged and His-tagged prokaryotic expression vectors, respectively; and expressed in Escherichia coli. The recombinant proteins were subsequently purified by affinity chromatography using GST and His-Trap resins. The diagnostic potential of each purified recombinant antigen was tested with various immunoglobulin classes (IgG, IgM, and IgE) and IgG subclasses. The IgG4 ELISA was determined to have the highest specificity and was further evaluated using a panel of serum samples. The rTES-26 IgG4 ELISA showed 80.0% (24/30 samples positive) sensitivity, and both the rTES-30USM IgG4 ELISA and rTES-120 IgG4 ELISA had 93.0% (28/30) sensitivity. Combined use of rTES-120 and rTES-30 IgG4 ELISA for the diagnosis of toxocariasis provided 100% sensitivity. The specificities of rTES-26, rTES-30USM, and rTES-120 antigens were 96.2%, 93.9%, and 92.0%, respectively. These results indicate that the development of a diagnostic test using the three recombinant antigens will allow for more-accurate detection of toxocariasis.

  1. Detection of Plasmodium knowlesi, Plasmodium falciparum and Plasmodium vivax using loop-mediated isothermal amplification (LAMP) in a co-endemic area in Malaysia.

    PubMed

    Piera, Kim A; Aziz, Ammar; William, Timothy; Bell, David; González, Iveth J; Barber, Bridget E; Anstey, Nicholas M; Grigg, Matthew J

    2017-01-13

    Plasmodium knowlesi is the most common cause of malaria in Malaysia. However, microscopic diagnosis is inaccurate and rapid diagnostic tests (RDTs) are insufficiently sensitive. PCR is sensitive and specific but not feasible at a district level. Loop-mediated isothermal amplification (LAMP) shows potential with only basic requirements. A commercially available LAMP assay, the Eiken Loopamp™ MALARIA Pan Detection kit, is sensitive for Plasmodium falciparum and Plasmodium vivax, but has not previously been evaluated for P. knowlesi. This study aims to determine the sensitivity of this LAMP assay for detecting P. knowlesi infection. Study participants included 73 uncomplicated malaria patients with PCR species confirmation: 50 P. knowlesi, 20 P. falciparum and 3 P. vivax. Nineteen malaria-negative, non-endemic area controls were also included. The sensitivity of the Eiken Loopamp™ MALARIA Pan Detection kit (Pan LAMP) for detecting each Plasmodium species was evaluated. Sensitivity and specificity of the Eiken Loopamp™ MALARIA Pf Detection kit (Pf LAMP) for P. falciparum were also determined. The limit of detection for each LAMP assay was evaluated, with results compared to PCR. All P. knowlesi patients were also tested by CareStart™ (Pf/VOM) and OptiMAL-IT™ (Pan/Pf) RDTs. The sensitivity of the Pan LAMP assay was 100% for P. knowlesi (95% CI 92.9-100), P. falciparum (95% CI 83.2-100), and P. vivax (95% CI 29.2-100). The Pf LAMP was 100% sensitive and specific for P. falciparum detection, with all P. knowlesi samples having a negative reaction. LAMP sensitivity was superior to both RDTs, with only 10 and 28% of P. knowlesi samples testing positive to CareStart™ and OptiMAL-IT™, respectively. Limit of detection using the Pan LAMP for both P. knowlesi and P. vivax was 2 parasites/μL, comparable to PCR. For P. falciparum both the Pan LAMP and Pf LAMP demonstrated a limit of detection of 20 parasites/μL. The Eiken Loopamp™ MALARIA Pan Detection kit is sensitive for detection of P. knowlesi in low parasitaemia clinical infections, as well as P. falciparum and P. vivax. However, a P. knowlesi-specific field assay in a simpler format would assist correct species identification and initiation of optimal treatment for all malaria patients.

  2. Field evaluation of the photo-induced electron transfer fluorogenic primers (PET) real-time PCR for the detection of Plasmodium falciparum in Tanzania.

    PubMed

    Talundzic, Eldin; Maganga, Mussa; Masanja, Irene M; Peterson, David S; Udhayakumar, Venkatachalam; Lucchi, Naomi W

    2014-01-27

    Accurate diagnosis of malaria infections remains challenging, especially in the identification of submicroscopic infections. New molecular diagnostic tools that are inexpensive, sensitive enough to detect low-level infections and suitable in laboratory settings of resource-limited countries are required for malaria control and elimination programmes. Here the diagnostic potential of a recently developed photo-induced electron transfer fluorogenic primer (PET) real-time polymerase chain reaction (PCR) called PET-PCR was investigated. This study aimed to (i) evaluate the use of this assay as a method for the detection of both Plasmodium falciparum and other Plasmodium species infections in a developing country's diagnostic laboratory; and, (ii) determine the assay's sensitivity and specificity compared to a nested 18S rRNA PCR. Samples used in this study were obtained from a previous study conducted in the region of Iringa, Tanzania. A total of 303 samples from eight health facilities in Tanzania were utilized for this evaluation. All samples were screened using the multiplex PET-PCR assay designed to detect Plasmodium genus and P. falciparum initially in laboratory in Tanzania and then repeated at a reference laboratory at the CDC in the USA. Microscopy data was available for all the 303 samples. A subset of the samples were tested in a blinded fashion to find the sensitivity and specificity of the PET-PCR compared to the nested 18S rRNA PCR. Compared to microscopy, the PET-PCR assay was 59% more sensitive in detecting P. falciparum infections. The observed sensitivity and specificity were 100% (95% confidence interval (CI0.95) = 94-100%) and (CI0.95 = 96-100%), respectively, for the PET-PCR assay when compared to nested 18S rRNA PCR. When compared to 18S rRNA PCR, microscopy had a low sensitivity of 40% (CI0.95 = 23-61%) and specificity of 100% (CI0.95 = 96-100%). The PET-PCR results performed in the field laboratory in Tanzania were in 100% concordance with the results obtained at the reference laboratory in the USA. The PET-PCR is a new molecular diagnostic tool with similar performance characteristics as commonly used PCR methods that is less expensive, easy to use, and amiable to large scale-surveillance studies in developing country settings.

  3. Paradigm for diagnosing mycobacterial disease: direct detection and differentiation of Mycobacterium tuberculosis complex and non-tuberculous mycobacteria in clinical specimens using multiplex real-time PCR.

    PubMed

    Kim, Jeong-Uk; Ryu, Dae-Shick; Cha, Choong-Hwan; Park, Seon-Hee

    2018-03-20

    Mycobacterium tuberculosis and non-tuberculous mycobacteria (NTM) are clinically different, and the rapid detection and differentiation of M. tuberculosis complex (MTBC) and NTM is crucial for patient management and infection control. Given the slow growth of most pathogenic mycobacteria, nucleic acid amplification assays are excellent tools for direct identification of mycobacteria in clinical specimens. Recently, a multiplex real-time PCR assay was developed that can directly detect 20 mycobacterial species in clinical specimens. Here, we evaluated the diagnostic performance of the assay for diagnosing mycobacterial disease under routine laboratory conditions. A total of 3334 specimens collected from 1437 patients suspected of tuberculosis infection were subjected to acid-fast bacilli staining, conventional culture and the multiplex real-time PCR assay. To evaluate the sensitivity and specificity of the assay, the overall diagnosis of tuberculosis was defined by positive culture plus medical history, and the 2007 American Thoracic Society and Infectious Disease Society of America diagnostic criteria for NTM disease were applied. The sensitivity, specificity, positive predictive value and negative predictive value were 87.5%, 99.6%, 96.1% and 98.5%, respectively, for the detection of MTBC isolates and 53.3%, 99.9%, 95.2%, and 98.9%, respectively, for detecting NTM isolates. Thus, the assay can correctly differentiate between MTBC and NTM isolates in clinical specimens and would be a useful tool for the rapid differentiation of tuberculosis and NTM disease, despite its limited sensitivity for the diagnosis of NTM disease. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Clinical evaluation of the Abbott RealTime MTB Assay for direct detection of Mycobacterium tuberculosis-complex from respiratory and non-respiratory samples.

    PubMed

    Hinić, Vladimira; Feuz, Kinga; Turan, Selda; Berini, Andrea; Frei, Reno; Pfeifer, Karin; Goldenberger, Daniel

    2017-05-01

    Rapid and reliable diagnosis is crucial for correct management of tuberculosis. The Abbott RealTime MTB Assay represents a novel qualitative real-time PCR assay for direct detection of M. tuberculosis-complex (MTB) DNA from respiratory samples. The test targets two highly conserved sequences, the multi-copy insertion element IS6110 and the protein antigen B (PAB) gene of MTB, allowing even the detection of IS6610-deficient strains. We evaluated this commercial diagnostic test by analyzing 200 respiratory and, for the first time, 87 non-respiratory clinical specimens from our tertiary care institution and compared its results to our IS6110-based in-house real-time PCR for MTB as well as MTB culture. Overall sensitivity for Abbott RealTime MTB was 100% (19/19) in smear positive and 87.5% (7/8) in smear negative specimens, while the specificity of the assay was 100% (260/260). For both non-respiratory smear positive and smear negative specimens Abbott RealTime MTB tests showed 100% (8/8) sensitivity and 100% (8/8) specificity. Cycle threshold (Ct) value analysis of 16 MTB positive samples showed a slightly higher Ct value of the Abbott RealTime MTB test compared to our in-house MTB assay (mean delta Ct = 2.55). In conclusion, the performance of the new Abbott RealTime MTB Assay was highly similar to culture and in-house MTB PCR. We document successful analysis of 87 non-respiratory samples with the highly automated Abbott RealTime MTB test with no inhibition observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Evaluation of RIDA®GENE norovirus GI/GII real time RT-PCR using stool specimens collected from children and adults with acute gastroenteritis.

    PubMed

    Kanwar, N; Hassan, F; Barclay, L; Langley, C; Vinjé, J; Bryant, P W; George, K St; Mosher, L; Matthews-Greer, J M; Rocha, M A; Beenhouwer, D O; Harrison, C J; Moffatt, M; Shastri, N; Selvarangan, R

    2018-04-10

    Norovirus is the leading cause of epidemic and sporadic acute gastroenteritis (AGE) in the United States. Widespread prevalence necessitates implementation of accurate norovirus detection assays in clinical diagnostic laboratories. To evaluate RIDA ® GENE norovirus GI/GII real-time RT-PCR assay (RGN RT-PCR) using stool samples from patients with sporadic AGE. Patients between 14 days to 101 years of age with symptoms of AGE were enrolled prospectively at four sites across the United States during 2014-2015. Stool specimens were screened for the presence of norovirus RNA by the RGN RT-PCR assay. Results were compared with a reference method that included conventional RT-PCR and sequencing of a partial region of the 5'end of the norovirus ORF2 gene. A total of 259 (36.0%) of 719 specimens tested positive for norovirus by the reference method. The RGN RT-PCR assay detected norovirus in 244 (94%) of these 259 norovirus positive specimens. The sensitivity and specificity (95% confidence interval) of the RGN RT-PCR assay for detecting norovirus genogroup (G) I was 82.8% (63.5-93.5) and 99.1% (98.0-99.6) and for GII was 94.8% (90.8-97.2) and 98.6% (96.9-99.4), respectively. Seven specimens tested positive by the RGN-RT PCR that were negative by the reference method. The fifteen false negative samples were typed as GII.4 Sydney, GII.13, GI.3, GI.5, GI.2, GII.1, and GII.3 in the reference method. The RGN RT-PCR assay had a high sensitivity and specificity for the detection of norovirus in stool specimens from patients with sporadic AGE. Copyright © 2018. Published by Elsevier B.V.

  6. Multiplex Detection of Rare Mutations by Picoliter Droplet Based Digital PCR: Sensitivity and Specificity Considerations

    PubMed Central

    Zonta, Eleonora; Garlan, Fanny; Pécuchet, Nicolas; Perez-Toralla, Karla; Caen, Ouriel; Milbury, Coren; Didelot, Audrey; Fabre, Elizabeth; Blons, Hélène; Laurent-Puig, Pierre; Taly, Valérie

    2016-01-01

    In cancer research, the accuracy of the technology used for biomarkers detection is remarkably important. In this context, digital PCR represents a highly sensitive and reproducible method that could serve as an appropriate tool for tumor mutational status analysis. In particular, droplet-based digital PCR approaches have been developed for detection of tumor-specific mutated alleles within plasmatic circulating DNA. Such an approach calls for the development and validation of a very significant quantity of assays, which can be extremely costly and time consuming. Herein, we evaluated assays for the detection and quantification of various mutations occurring in three genes often misregulated in cancers: the epidermal growth factor receptor (EGFR), the v-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog (KRAS) and the Tumoral Protein p53 (TP53) genes. In particular, commercial competitive allele-specific TaqMan® PCR (castPCR™) technology, as well as TaqMan® and ZEN™ assays, have been evaluated for EGFR p.L858R, p.T790M, p.L861Q point mutations and in-frame deletions Del19. Specificity and sensitivity have been determined on cell lines DNA, plasmatic circulating DNA of lung cancer patients or Horizon Diagnostics Reference Standards. To show the multiplexing capabilities of this technology, several multiplex panels for EGFR (several three- and four-plexes) have been developed, offering new "ready-to-use" tests for lung cancer patients. PMID:27416070

  7. Use of Direct LAMP Screening of Broiler Fecal Samples for Campylobacter jejuni and Campylobacter coli in the Positive Flock Identification Strategy.

    PubMed

    Sabike, Islam I; Uemura, Ryoko; Kirino, Yumi; Mekata, Hirohisa; Sekiguchi, Satoshi; Okabayashi, Tamaki; Goto, Yoshitaka; Yamazaki, Wataru

    2016-01-01

    Rapid identification of Campylobacter -positive flocks before slaughter, following freezing and heat treatment for the Campylobacter -positive carcasses at the slaughterhouses is an effective control strategy against foodborne campylobacteriosis. We evaluated a loop-mediated isothermal amplification (LAMP) assay for the direct screening of naturally contaminated chicken cloacal swabs for C. jejuni / C. coli to compare this assay with conventional quantitative culture methods. In a comparison study of 165 broilers, the LAMP assay showed 82.8% (48/58 by conventional culture) sensitivity, 100% (107/107) specificity, 100% (48/48) positive predictive value (PPV), and 91.5% (107/117) negative predictive value (NPV). In a comparison of 55 flocks, LAMP showed 90.5% (19/21) sensitivity, 100% (34/34) specificity, 100% (19/19) PPV, and 94.4% (34/36) NPV. In the cumulative total of 28 farm-level comparisons, LAMP showed 100% (12/12) sensitivity, 100% (16/16) specificity, 100% (12/12) PPV, and 100% (16/16) NPV. The LAMP assay required less than 90 min from the arrival of the fecal samples to final results in the laboratory. This suggests that the LAMP assay will facilitate the identification of C. jejuni / C. coli -positive broiler flocks at the farm level or in slaughterhouses before slaughtering, which would make it an effective tool in preventing the spread of Campylobacter contamination.

  8. Evaluation of wondfo rapid diagnostic kit (Pf-HRP2/PAN-pLDH) for diagnosis of malaria by using nano-gold immunochromatographic assay.

    PubMed

    Wu, Junlin; Peng, Yunping; Liu, Xiaoyun; Li, Wenmei; Tang, Shixing

    2014-06-01

    Prompt and accurate diagnosis is necessary to start adequate treatment for different affecting species including P. falciparum and P. vivax. Here we described the Wondfo Rapid diagnostic Kit (Pf-HRP2/PAN-pLDH) for the detection of P. falciparum and pan-plasmodium in patient specimen by using a nano-gold immunochromatographic assay. Our rapid assay adapted nano-gold labeling techniques and the monoclonal antibodies (mAbs) against both histidine rich protein-2 (Pf HRP-2) of P. falciparum and pan plasmodium-specific pLDH (pan pLDH). The established two-antibody sandwich immunochromatographic assay could detect P. falciparum and pan-plasmodium. The sensitivity and specificity of Wondfo rapid diagnostic kit were determined by comparing with the "gold standard" of microscopic examination of blood smears. In this study1023 blood samples were collected from outpatient clinics in China and Burma, and detected by both Wondfo kit and microscopic examination. The detection sensitivity and specificity of Wondfo rapid diagnostic kit were 96.46% and 99.67% for P. falciparum (HRP2), 95.03% and 99.24% for pLDH, 96.83% and 99.74% for non-falciparum species, 96.70% and 99.74% for P. vivax, respectively. These results indicate that Wondfo rapid diagnostic assay may be useful for detecting P. falciparum and non-P. falciparum (especially P.v.) in patient specimen.

  9. Production of a monoclonal antibody against serum immunoglobulin M of South American camelids and assessment of its suitability in two immunoassays.

    PubMed

    Friedrich, Adrián; Ledesma, Martín; Landone, Ignacio; Ferrari, Alejandro; Leoni, Juliana

    2014-09-01

    A monoclonal antibody (mAb) was produced against immunoglobulin M (IgM) of South American camelids. A single radial immunodiffusion (SRID) assay and a competitive enzyme-linked immunosorbent assay (ELISA) were developed to measure IgM in serum samples. Isotype and specificity of the mAb were assessed. The performance of the SRID assay was preliminarily evaluated in terms of working range, plate stability over a 4-week period, and initial intra- and interassay variation. The concentration of IgM was determined in 55 samples by SRID assay and ELISA, and results were not significantly different by t-test (0.64 ± 0.19 mg/ml for the SRID assay, and 0.58 ± 0.24 mg/ml for ELISA; P = 0.1489). The mAb was shown to be stable over the 4-week evaluation period, and the SRID assay was reproducible when tested in triplicate for intra-assay variability and in quadruplicate for interassay variability, with a percentage coefficient of variation of less than or equal to 5%. Also, the SRID assay proved to be sensitive enough to measure IgM levels in undiluted serum samples, and had a good correlation with ELISA. The current study is intended to submit a preliminary report of a mAb against IgM of South American camelids, and suggest the future potential of the mAb developed for diagnostic application, including use in the SRID assay. © 2014 The Author(s).

  10. Variola Virus-Specific Diagnostic Assays: Characterization, Sensitivity, and Specificity

    PubMed Central

    Kondas, Ashley V.; Olson, Victoria A.; Li, Yu; Abel, Jason; Laker, Miriam; Rose, Laura; Wilkins, Kimberly; Turner, Jonathan; Kline, Richard

    2015-01-01

    A public health response relies upon rapid and reliable confirmation of disease by diagnostic assays. Here, we detail the design and validation of two variola virus-specific real-time PCR assays, since previous assays cross-reacted with newly identified cowpox viruses. The assay specificity must continually be reassessed as other closely related viruses are identified. PMID:25673790

  11. Validation and Application of a Real-time PCR Protocol for the Specific Detection and Quantification of Clavibacter michiganensis subsp. sepedonicus in Potato.

    PubMed

    Cho, Min Seok; Park, Duck Hwan; Namgung, Min; Ahn, Tae-Young; Park, Dong Suk

    2015-06-01

    Clavibacter michiganensis subsp. sepedonicus (Cms) multiplies very rapidly, passing through the vascular strands and into the stems and petioles of a diseased potato. Therefore, the rapid and specific detection of this pathogen is highly important for the effective control of the pathogen. Although several PCR assays have been developed for detection, they cannot afford specific detection of Cms. Therefore, in this study, a computational genome analysis was performed to compare the sequenced genomes of the C. michiganensis subspecies and to identify an appropriate gene for the development of a subspecies-specific PCR primer set (Cms89F/R). The specificity of the primer set based on the putative phage-related protein was evaluated using genomic DNA from seven isolates of Cms and 27 other reference strains. The Cms89F/R primer set was more specific and sensitive than the existing assays in detecting Cms in in vitro using Cms cells and its genomic DNA. This assay was also able to detect at least 1.47×10(2) copies/μl of cloned-amplified target DNA, 5 fg of DNA using genomic DNA or 10(-6) dilution point of 0.12 at OD600 units of cells per reaction using a calibrated cell suspension.

  12. Validation and Application of a Real-time PCR Protocol for the Specific Detection and Quantification of Clavibacter michiganensis subsp. sepedonicus in Potato

    PubMed Central

    Cho, Min Seok; Park, Duck Hwan; Namgung, Min; Ahn, Tae-Young; Park, Dong Suk

    2015-01-01

    Clavibacter michiganensis subsp. sepedonicus (Cms) multiplies very rapidly, passing through the vascular strands and into the stems and petioles of a diseased potato. Therefore, the rapid and specific detection of this pathogen is highly important for the effective control of the pathogen. Although several PCR assays have been developed for detection, they cannot afford specific detection of Cms. Therefore, in this study, a computational genome analysis was performed to compare the sequenced genomes of the C. michiganensis subspecies and to identify an appropriate gene for the development of a subspecies-specific PCR primer set (Cms89F/R). The specificity of the primer set based on the putative phage-related protein was evaluated using genomic DNA from seven isolates of Cms and 27 other reference strains. The Cms89F/R primer set was more specific and sensitive than the existing assays in detecting Cms in in vitro using Cms cells and its genomic DNA. This assay was also able to detect at least 1.47×102 copies/μl of cloned-amplified target DNA, 5 fg of DNA using genomic DNA or 10−6 dilution point of 0.12 at OD600 units of cells per reaction using a calibrated cell suspension. PMID:26060431

  13. Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT).

    PubMed

    Mens, Petra F; Matelon, Raphael J; Nour, Bakri Y M; Newman, Dave M; Schallig, Henk D F H

    2010-07-19

    This study describes the laboratory evaluation of a novel diagnostic platform for malaria. The Magneto Optical Test (MOT) is based on the bio-physical detection of haemozoin in clinical samples. Having an assay time of around one minute, it offers the potential of high throughput screening. Blood samples of confirmed malaria patients from different regions of Africa, patients with other diseases and healthy non-endemic controls were used in the present study. The samples were analysed with two reference tests, i.e. an histidine rich protein-2 based rapid diagnostic test (RDT) and a conventional Pan-Plasmodium PCR, and the MOT as index test. Data were entered in 2 x 2 tables and analysed for sensitivity and specificity. The agreement between microscopy, RDT and PCR and the MOT assay was determined by calculating Kappa values with a 95% confidence interval. The observed sensitivity/specificity of the MOT test in comparison with clinical description, RDT or PCR ranged from 77.2 - 78.8% (sensitivity) and from 72.5 - 74.6% (specificity). In general, the agreement between MOT and the other assays is around 0.5 indicating a moderate agreement between the reference and the index test. However, when RDT and PCR are compared to each other, an almost perfect agreement can be observed (k = 0.97) with a sensitivity and specificity of >95%. Although MOT sensitivity and specificity are currently not yet at a competing level compared to other diagnostic test, such as PCR and RDTs, it has a potential to rapidly screen patients for malaria in endemic as well as non-endemic countries.

  14. Monocyte-endothelial adhesion in chronic rheumatoid arthritis. In situ detection of selectin and integrin-dependent interactions.

    PubMed Central

    Grober, J S; Bowen, B L; Ebling, H; Athey, B; Thompson, C B; Fox, D A; Stoolman, L M

    1993-01-01

    Blood monocytes are the principal reservoir for tissue macrophages in rheumatoid synovitis. Receptor-mediated adhesive interactions between circulating cells and the synovial venules initiate recruitment. These interactions have been studied primarily in cultured endothelial cells. Thus the functional activities of specific adhesion receptors, such as the endothelial selectins and the leukocytic integrins, have not been evaluated directly in diseased tissues. We therefore examined monocyte-microvascular interactions in rheumatoid synovitis by modifying the Stamper-Woodruff frozen section binding assay initially developed to study lymphocyte homing. Specific binding of monocytes to venules lined by low or high endothelium occurred at concentrations as low as 5 x 10(5) cells/ml. mAbs specific for P-selectin (CD62, GMP-140/PADGEM) blocked adhesion by > 90% in all synovitis specimens examined. In contrast, P-selectin-mediated adhesion to the microvasculature was either lower or absent in frozen sections of normal foreskin and placenta. mAbs specific for E-selectin (ELAM-1) blocked 20-50% of monocyte attachment in several RA synovial specimens but had no effect in others. mAbs specific for LFA-1, Mo1/Mac 1, the integrin beta 2-chain, and L-selectin individually inhibited 30-40% of adhesion. An mAb specific for the integrin beta 1-chain inhibited the attachment of elutriated monocytes up to 20%. We conclude that P-selectin associated with the synovial microvasculature initiates shear-resistant adhesion of monocytes in the Stamper-Woodruff assay and stabilizes bonds formed by other selectins and the integrins. Thus the frozen section binding assay permits direct evaluation of leukocyte-microvascular adhesive interactions in inflamed tissues and suggests a prominent role for P-selectin in monocyte recruitment in vivo. Images PMID:7685772

  15. Development of a LAMP assay for detection of Leishmania infantum infection in dogs using conjunctival swab samples.

    PubMed

    Gao, Chun-hua; Ding, Dan; Wang, Jun-yun; Steverding, Dietmar; Wang, Xia; Yang, Yue-tao; Shi, Feng

    2015-07-15

    Leishmania infantum infections in dogs play a crucial role in the transmission of pathogens causing visceral leishmaniasis to humans in the Gansu province, northwest China. To be able to control zoonotic transmission of the parasite to humans, a non-invasive loop-mediated isothermal amplification (LAMP) assay to specifically detect L. infantum infections in dogs was developed. The primers used in the LAMP assay were designed to target kinetoplast DNA minicircle sequences of the L. infantum isolate MCAN/CN/90/SC and tested using DNA isolated from promastigotes of different Leishmania species. The LAMP assay was evaluated with conjunctional swab samples obtained from 111 and 33 dogs living in an endemic and a non-endemic region of zoonotic visceral leishmaniasis in the Gansu province, respectively. The LAMP assay was also compared with conventional PCR, ELISA and microscopy using conjunctional swab, serum and bone marrow samples from the dogs, respectively. The LAMP assay detected 1 fg of L. infantum DNA purified from cultured promastigotes which was 10-fold more sensitive than a conventional PCR test using Leishmania genus-specific primers. No cross reaction was observed with DNA isolated from promastigotes of L. donovani, L. major, L. tropica, and L. braziliensis, and the L. infantum reference strain MHOM/TN/80/IPT1. The L. infantum-positive rates obtained for field-collected samples were 61.3%, 58.6%, 40.5% and 10.8% by LAMP, PCR, ELISA and microscopy, respectively. As only one out of the 33 samples from control dogs from the non-endemic region of zoonotic visceral leishmaniasis was positive by the LAMP assay and the PCR test, the observed true negative rate (specificity) was 97% for both methods. This study has shown that the non-invasive, conjunctional swab-based LAMP assay developed was more sensitive in the detection of leishmaniasis in dogs than PCR, ELISA and microscopy. The findings indicate that the LAMP assay is a sensitive and specific method for the field surveillance of domestic dogs, particularly of asymptomatic canines, in ZVL-endemic areas in western China.

  16. Simultaneous detection of eight avian influenza A virus subtypes by multiplex reverse transcription-PCR using a GeXP analyser.

    PubMed

    Li, Meng; Xie, Zhixun; Xie, Zhiqin; Liu, Jiabo; Xie, Liji; Deng, Xianwen; Luo, Sisi; Fan, Qing; Huang, Li; Huang, Jiaoling; Zhang, Yanfang; Zeng, Tingting; Wang, Sheng

    2018-04-18

    Recent studies have demonstrated that at least eight subtypes of avian influenza virus (AIV) can infect humans, including H1, H2, H3, H5, H6, H7, H9 and H10. A GeXP analyser-based multiplex reverse transcription (RT)-PCR (GeXP-multiplex RT-PCR) assay was developed in our recent studies to simultaneously detect these eight AIV subtypes using the haemagglutinin (HA) gene. The assay consists of chimeric primer-based PCR amplification with fluorescent labelling and capillary electrophoresis separation. RNA was extracted from chick embryo allantoic fluid or liquid cultures of viral isolates. In addition, RNA synthesised via in vitro transcription was used to determine the specificity and sensitivity of the assay. After selecting the primer pairs, their concentrations and GeXP-multiplex RT-PCR conditions were optimised. The established GeXP-multiplex RT-PCR assay can detect as few as 100 copies of premixed RNA templates. In the present study, 120 clinical specimens collected from domestic poultry at live bird markets and from wild birds were used to evaluate the performance of the assay. The GeXP-multiplex RT-PCR assay specificity was the same as that of conventional RT-PCR. Thus, the GeXP-multiplex RT-PCR assay is a rapid and relatively high-throughput method for detecting and identifying eight AIV subtypes that may infect humans.

  17. Duplex detection of the Mycobacterium tuberculosis complex and medically important non-tuberculosis mycobacteria by real-time PCR based on the rnpB gene.

    PubMed

    Abdeldaim, Guma; Svensson, Erik; Blomberg, Jonas; Herrmann, Björn

    2016-11-01

    A duplex real-time PCR based on the rnpB gene was developed for Mycobacterium spp. The assay was specific for the Mycobacterium tuberculosis complex (MTB) and also detected all 19 tested species of non-tuberculous mycobacteria (NTM). The assay was evaluated on 404 clinical samples: 290 respiratory samples and 114 from tissue and other non-respiratory body sites. M. tuberculosis was detected by culture in 40 samples and in 30 samples by the assay. The MTB assay showed a sensitivity similar to Roche Cobas Amplicor MTB-PCR (Roche Molecular Systems, Pleasanton, CA, USA). There were only nine samples with non-tuberculous mycobacteria detected by culture. Six of them were detected by the PCR assay. © 2016 APMIS. Published by John Wiley & Sons Ltd.

  18. Colorimetric detection of Cucumber green mottle mosaic virus using unmodified gold nanoparticles as colorimetric probes.

    PubMed

    Wang, Lin; Liu, Zhanmin; Xia, Xueying; Yang, Cuiyun; Huang, Junyi; Wan, Sibao

    2017-05-01

    Cucumber green mottle mosaic virus (CGMMV)causes a severe mosaic symptom of watermelon and cucumber, and can be transmitted via infected cucumber seeds, leaves and soil. It remains a challenge to detect this virus to prevent its introduction and infection and spread in fields. For this purpose, a simple and sensitive label-free colorimetric detection method for CGMMV has been developed with unmodified gold nanoparticles (AuNPs) as colorimetric probes. The method is based on the finding that the presence of RT-PCR target products of CGMMV and species-specific probes results in color change of AuNPs from red to blue after NaCl induction. Normally, species-specific probes attach to the surface of AuNPs and thereby increasing their resistance to NaCl-induced aggregation. The concentration of sodium, probes in the reaction system and evaluation of specificity and sensitivity of a novel assay, visual detection of Cucumber green mottle mosaic virus using unmodified AuNPs has been carried out with simple preparation of samples in our study. Through this assay, as low as 30pg/μL of CGMMV RNA was thus detected visually, by the naked eye, without the need for any sophisticated, expensive instrumentation and biochemical reagents. The specificity was 100% and exhibited good reproducibility in our assays. The results note that this assay is highly species-specific, simple, low-cost, and visual for easy detection of CGMMV in plant tissues. Therefore, visual assay is a potentially useful tool for middle or small-scales corporations and entry-exit inspection and quarantine bureau to detect CGMMV in cucumber seeds or plant tissues. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Evaluation of automated assays for immunoglobulin G, M, and A measurements in dog and cat serum.

    PubMed

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Caldin, Marco; Tecles, Fernando; Ceron, Jose J

    2013-09-01

    Measurements of immunoglobulins (Igs) in companion animals can be useful to detect deficiencies of the humoral immune system, that can be associated with opportunistic or chronic infections, or other immune-mediated disorders including B-cell neoplasms. The purpose of this study was to evaluate commercially available automated immunoturbidimetric assays designed for human IgG, M, and A measurements in canine and feline serum using species-specific calibrators. Canine and feline serum samples with different IgG, M, and A concentrations were used for the analytical validation of the assays. Intra- and inter-assay precision, linearity under dilution, spiking recovery, and limit of detection were determined. In addition, effects of lipemia, hemolysis, and bilirubinemia were evaluated. Finally, Ig concentrations were determined in small groups of diseased dogs and cats, and compared with healthy groups. Spiking recovery and linearity under dilution tests showed that the assays measured Igs in canine and feline serum samples precisely and accurately. Intra- and inter-assay imprecisions were lower than 15% in all cases. Significantly higher IgG, IgM, and IgA levels were observed in dogs with leishmaniasis, while dogs with pyometra showed a statistically significant increase in IgM and IgA concentrations in comparison with healthy dogs. Significantly higher IgG and IgM levels were observed in FIV-infected cats compared with healthy ones. The automated human Ig assays showed adequate precision and accuracy with serum samples from dogs and cats. Also, they were able to discriminate different concentrations of Igs in healthy and diseased animals. © 2013 American Society for Veterinary Clinical Pathology.

  20. Comparative evaluation of the INNO-LIA syphilis score and the MarDx Treponema pallidum immunoglobulin G Marblot test assays for the serological diagnosis of syphilis.

    PubMed

    Lam, T K; Lau, H Y; Lee, Y P; Fung, S M; Leung, W L; Kam, K M

    2010-02-01

    We evaluated the performance of two immunoblot assays: the INNO-LIA Syphilis Score (LIA) and the MarDx T. pallidum IgG Marblot Test (TWB), as compared with that of the Murex ICE Syphilis enzyme immunoassay (EIA), the Serodia Treponema pallidum particle agglutination (TPPA) assay and the fluorescent treponemal antibody-absorption (FTA-abs) assay, for the serological diagnosis of syphilis using serum samples of 135 attendees of the social hygiene clinics of the Department of Health in Hong Kong newly diagnosed with syphilis and provided with clinical stages (39 in primary, 20 in secondary, 18 in early latent and 58 in latent of unknown duration) and of 43 normal healthy subjects between October and December 2004. The differences in the overall sensitivities of the LIA assay and the EIA/TPPA/FTA-abs assays were not statistically significant (P > 0.05) whereas the overall sensitivity of the TWB assay was significantly lower (P < 0.05) than the overall sensitivities of the EIA, the TPPA and the FTA-abs assays. The LIA assay had an overall sensitivity of 94.1% (95% CI 88.7-97.0%) whereas the TWB assay 65.2% (95% CI 56.8-72.7%). Both the LIA and the TWB assays have a specificity of 100%. When consensus results were derived from the most predominant results of the EIA, the TPPA and the FTA-abs assays, the LIA assay had a positive agreement with the consensus results of 98.5% (95% CI 94.5-99.6%) whereas the TWB assay 68.2% (95% CI 59.8-75.6%). Therefore, the LIA assay performed significantly better (P < 0.05) than the TWB assay. The LIA assay can be considered to be a valid alternative confirmatory test for the serological diagnosis of syphilis.

  1. Evaluation of Multiplex Type-Specific Real-Time PCR Assays Using the LightCycler and Joint Biological Agent Identification and Diagnostic System Platforms for Detection and Quantitation of Adult Human Respiratory Adenoviruses

    DTIC Science & Technology

    2010-04-01

    53592), Escherichia coli, Klebsiella pneu- moniae (ATCC 13883), Pseudomonas aeruginosa (ATCC 97), Mycoplasma pneu- moniae, and Legionella pneumophila... Legionella pneumophila. Additionally, when we tested all samples with the multiplex assays, we did not see any cross- reactivity (data not shown...Chlamydophila pneumoniae Escherichia coli Klebsiella pneumoniae Pseudomonas aeruginosa Mycoplasma pneumoniae Legionella pneumophila VOL. 48, 2010

  2. [Detection of Plasmodium falciparum by using magnetic nanoparticles separation-based quantitative real-time PCR assay].

    PubMed

    Wang, Fei; Tian, Yin; Yang, Jing; Sun, Fu-Jun; Sun, Ning; Liu, Bi-Yong; Tian, Rui; Ge, Guang-Lu; Zou, Ming-qiang; Deng, Cong-liang; Liu, Yi

    2014-10-01

    To establish a magnetic nanoparticles separation-based quantitative real-time PCR (RT-PCR) assay for fast and accurate detection of Plasmodium falciparum and providing a technical support for improving the control and prevention of imported malaria. According to the conserved sequences of the P. falciparum genome 18SrRNA, the species-specific primers and probe were designed and synthetized. The RT-PCR was established by constructing the plasmid standard, fitting the standard curve and using magnetic nanoparticles separation. The sensitivity and specificity of the assay were evaluated. The relationship between the threshold cycle (Ct) and logarithm of initial templates copies was linear over a range of 2.5 x 10(1) to 2.5 x 10(8) copies/μl (R2 = 0.999). Among 13 subjects of entry frontier, a P. falciparum carrier with low load was detected by using the assay and none was detected with the conventional examinations (microscopic examinations and rapid tests). This assay shows a high sensitivity in detection of P. falciparum, with rapid and accurate characteristics, and is especially useful in diagnosis of P. falciparum infectors with low parasitaemia at entry-exit frontier ports.

  3. Quantification of cytomegalovirus (CMV) viral load by the hybrid capture assay allows for early detection of CMV disease in lung transplant recipients.

    PubMed

    Bhorade, S M; Sandesara, C; Garrity, E R; Vigneswaran, W T; Norwick, L; Alkan, S; Husain, A N; McCabe, M A; Yeldandi, V

    2001-09-01

    We prospectively compared the hybrid capture system (HCS) assay with conventional cell culture and shell vial assay for the detection of cytomegalovirus (CMV) infection and disease in the lung transplant population. Between January 1999 and February 2000, 34 lung transplant patients at Loyola University Medical Center, who were considered to be at risk for CMV disease, underwent surveillance testing for CMV cell culture, shell vial assay and HCS assay according to a pre-determined schedule. In addition, bronchoscopy with bronchoalveolar lavage (BAL) and transbronchial biopsy were performed at regular intervals and for clinical indications. All BAL samples were sent for CMV cultures and biopsy specimens were analyzed for histopathologic evidence of CMV by immunoperoxidase staining using antibody to early immediate nuclear antigen. Ten patients developed CMV disease/syndrome during the course of the study. The sensitivity, specificity, positive predictive value and negative predictive value were >90% for the HCS assay. The sensitivity of the HCS assay (90%) was statistically significantly higher than the sensitivity of either the SV assay (40%) or the cell culture (50%). In addition, the HCS assay was able to detect CMV 50 +/- 67 days prior to clinical evidence of CMV disease and an average of 36 days prior to the other detection techniques. The HCS assay is a sensitive diagnostic technique able to reliably detect CMV disease earlier than other diagnostic methods in the lung transplant population. Future studies may be able to evaluate whether pre-emptive anti-viral therapy targeted to specific viral loads using the HCS assay will be beneficial in preventing morbidity associated with CMV disease.

  4. Evaluation of the Procleix Ultrio Elite Assay and the Panther-System for Individual NAT Screening of Blood, Hematopoietic Stem Cell, Tissue and Organ Donors.

    PubMed

    Heim, Albert

    2016-05-01

    The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p < 0.001) which included non-heart-beating ('cadaveric') donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors.

  5. Clinical Evaluation of Anti-Tuberculous Glycolipid Immunoglobulin G Antibody Assay for Rapid Serodiagnosis of Pulmonary Tuberculosis

    PubMed Central

    Maekura, Ryoji; Okuda, Yoshinari; Nakagawa, Masaru; Hiraga, Touru; Yokota, Souichirou; Ito, Masami; Yano, Ikuya; Kohno, Hiroaki; Wada, Masako; Abe, Chiyoji; Toyoda, Takeo; Kishimoto, Toshio; Ogura, Takeshi

    2001-01-01

    Previously we reported the development of a highly sensitive enzyme-linked immunosorbent assay specific for anti-tuberculous glycolipid (anti-TBGL) for the rapid serodiagnosis of tuberculosis. In this study, the usefulness of an anti-TBGL antibody assay kit for rapid serodiagnosis was evaluated in a controlled multicenter study. Antibody titers in sera from 318 patients with active pulmonary tuberculosis (216 positive for Mycobacterium tuberculosis in smear and/or culture tests and 102 smear and culture negative and clinically diagnosed), 58 patients with old tuberculosis, 177 patients with other respiratory diseases, 156 patients with nonrespiratory diseases, and 454 healthy subjects were examined. Sera from 256 younger healthy subjects from among the 454 healthy subjects were examined as a control. When the cutoff point of anti-TBGL antibody titer was determined as 2.0 U/ml, the sensitivity for active tuberculosis patients was 81.1% and the specificity was 95.7%. Sensitivity in patients with smear-negative and culture-negative active pulmonary tuberculosis was 73.5%. Even in patients with noncavitary minimally advanced lesions, the positivity rate (60.0%) and the antibody titer (4.6 ± 9.4 U/ml) were significantly higher than those in the healthy group. These results indicate that this assay using anti-TBGL antibody is useful for the rapid serodiagnosis of active pulmonary tuberculosis. PMID:11574580

  6. Antigen-capture blocking enzyme-linked immunosorbent assay based on a baculovirus recombinant antigen to differentiate Transmissible gastroenteritis virus from Porcine respiratory coronavirus antibodies.

    PubMed

    López, Lissett; Venteo, Angel; García, Marga; Camuñas, Ana; Ranz, Ana; García, Julia; Sarraseca, Javier; Anaya, Carmen; Rueda, Paloma

    2009-09-01

    A new commercially available antigen-capture, blocking enzyme-linked immunosorbent assay (antigen-capture b-ELISA), based on baculovirus truncated-S recombinant protein of Transmissible gastroenteritis virus (TGEV) and 3 specific monoclonal antibodies, was developed and evaluated by examining a panel of 453 positive Porcine respiratory coronavirus (PRCoV), 31 positive TGEV, and 126 negative field sera by using another commercially available differential coronavirus b-ELISA as the reference technique to differentiate TGEV- from PRCoV-induced antibodies. The recombinant S protein-based ELISA appeared to be 100% sensitive for TGEV and PRCoV detection and highly specific for TGEV and PRCoV detection (100% and 92.06%, respectively), when qualitative results (positive or negative) were compared with those of the reference technique. In variability experiments, the ELISA gave consistent results when the same serum was evaluated on different wells and different plates. These results indicated that truncated recombinant S protein is a suitable alternative to the complete virus as antigen in ELISA assays. The use of recombinant S protein as antigen offers great advantages because it is an easy-to-produce, easy-to-standardize, noninfectious antigen that does not require further purification or concentration. Those advantages represent an important improvement for antigen preparation, in comparison with other assays in which an inactivated virus from mammalian cell cultures is used.

  7. Serological diagnosis of Besnoitia bennetti infection in donkeys (Equus asinus).

    PubMed

    Ness, SallyAnne L; Schares, Gereon; Peters-Kennedy, Jeanine; Mittel, Linda D; Dubey, Jitender P; Bowman, Dwight D; Mohammed, Hussni O; Divers, Thomas J

    2014-11-01

    Besnoitiosis is an emerging infectious disease of donkeys (Equus asinus) in the United States for which there are currently no serologic methods of diagnosis. A study was performed to evaluate physical examination findings and 3 serologic assays for the detection of Besnoitia bennetti infection in donkeys. A prospective study of 416 donkeys from 6 privately owned herds across 5 U.S. states (New York, Pennsylvania, Vermont, Oregon, and Washington) was performed. Donkeys were examined for clinical lesions suggestive of besnoitiosis and evaluated for antibodies against B. bennetti using a fluorescent antibody test (FAT) and 2 immunoblot assays specific for bradyzoite and tachyzoite antigens, respectively. Donkeys were confirmed to be infected with B. bennetti by histology (cases; n = 32) and were compared to those with no clinical signs of besnoitiosis (controls; n = 384). Identifying clinical lesions in 2 or more locations correctly identified infected donkeys 83% of the time. Donkeys with besnoitiosis had significantly higher FAT titers (P < 0.001) and numbers of bradyzoite (P < 0.001) and tachyzoite (P < 0.001) immunoblot bands than control donkeys. The sensitivity and specificity of the serologic assays for detecting besnoitiosis was 88% and 96% for FAT, 81% and 91% for bradyzoite immunoblot, and 91% and 92% for tachyzoite immunoblot, respectively. Fluorescent antibody and immunoblot assays are effective at identifying donkeys with besnoitiosis and provide a more efficient and less invasive diagnostic alternative to histology. © 2014 The Author(s).

  8. Rapid genetic typing of diarrheagenic Escherichia coli using a two-tube modified molecular beacon based multiplex real-time PCR assay and its clinical application

    PubMed Central

    2014-01-01

    Background Diarrheagenic Escherichia coli (DEC), including Enterotoxigenic E.coli (ETEC), Enteroaggregative E.coli (EAEC), Enteropathogenic E.coli (EPEC), Enterohemolysin E.coli (EHEC) and Enteroinvasive E.coli (EIEC) causes diarrhea or hemolytic uremic syndromes among infants and travelers around the world. A rapid, reliable and repeatable method is urgent for identifying DEC so as to provide the reference for responding to diarrheal disease outbreak and the treatment of the diarrheal patients associated with DEC. Methods In this study, specific primers and modified molecular beacon probes of nine specific virulence genes, whose 5′end were added with homo tail sequence, were designed; and a two-tube modified molecular beacon based multiplex real–time PCR (rtPCR) assay for the identification of five Escherichia coli pathotypes, including ETEC, EAEC, EPEC, EHEC and EIEC was developed and optimized. Totally 102 bacterial strains, including 52 reference bacterial strains and 50 clinical strains were detected to confirm whether the target genes selected were specific. Then detection limits of the assay were tested. Lastly, the assay was applied to the detection of 11860 clinical samples to evaluate the specificity and sensitivity of the developed assay compared with the conventional PCR. Results The target genes were 100% specific as assessed on 102 bacterial strains since no cross-reactions were observed. The detection limits ranged from 88 CFU/mL (EHEC) to 880 CFU/mL (EPEC). Compared with the conventional PCR, the specificity and sensitivity of the multiplex rtPCR was 100% and over 99%, respectively. The coefficient of variation (CV) for each target gene ranged from 0.45% to 1.53%. 171 positive clinical samples were mostly identified as ETEC (n = 111, 64.9%) and EPEC (n = 38, 22.2%), which were the dominating pathotypes of DEC strains. Conclusion The developed multiplex rtPCR assay for the identification of DEC was high sensitive and specific and could be applied to the rapid identification of DEC in clinical and public health laboratories. PMID:25023669

  9. A Xylenol Orange-Based Screening Assay for the Substrate Specificity of Flavin-Dependent para-Phenol Oxidases.

    PubMed

    Ewing, Tom A; van Noord, Aster; Paul, Caroline E; van Berkel, Willem J H

    2018-01-14

    Vanillyl alcohol oxidase (VAO) and eugenol oxidase (EUGO) are flavin-dependent enzymes that catalyse the oxidation of para -substituted phenols. This makes them potentially interesting biocatalysts for the conversion of lignin-derived aromatic monomers to value-added compounds. To facilitate their biocatalytic exploitation, it is important to develop methods by which variants of the enzymes can be rapidly screened for increased activity towards substrates of interest. Here, we present the development of a screening assay for the substrate specificity of para -phenol oxidases based on the detection of hydrogen peroxide using the ferric-xylenol orange complex method. The assay was used to screen the activity of VAO and EUGO towards a set of twenty-four potential substrates. This led to the identification of 4-cyclopentylphenol as a new substrate of VAO and EUGO and 4-cyclohexylphenol as a new substrate of VAO. Screening of a small library of VAO and EUGO active-site variants for alterations in their substrate specificity led to the identification of a VAO variant (T457Q) with increased activity towards vanillyl alcohol (4-hydroxy-3-methoxybenzyl alcohol) and a EUGO variant (V436I) with increased activity towards chavicol (4-allylphenol) and 4-cyclopentylphenol. This assay provides a quick and efficient method to screen the substrate specificity of para -phenol oxidases, facilitating the enzyme engineering of known para- phenol oxidases and the evaluation of the substrate specificity of novel para -phenol oxidases.

  10. Rabbit anti-rabies immunoglobulins production and evaluation.

    PubMed

    Liu, Xinjian; Liu, Qiongqiong; Feng, Xiaomin; Tang, Qi; Wang, Zhongcan; Li, Suqing; Feng, Zhenqing; Zhu, Jin; Guan, Xiaohong

    2011-04-01

    Due to the disadvantages of human and equine rabies immunoglobulin, it is necessary to develop a substitute for HRIG and ERIG, especially for those people living in the developing countries. Because of higher affinity and lower immunogenicity of rabbit's immunoglobulins, anti-rabies immunoglobulins specific to rabies virus were produced in rabbits as a bioreactor, and had been characterized by ELISA, affinity assay, immunofluorescence assay (IFA), immunocytochemistry, rapid fluorescent focus inhibition test (RFFIT). ELISA, affinity assay and IFA showed that rabbit RIG (RRIG) bound specifically to rabies virions. RFFIT result showed that RRIG has neutralization activity. This result was confirmed in vivo in a Kunming mouse challenge model and the protection rate of the treatment with RRIG was higher (25%) than that offered by HRIG when mice were challenged with a lethal RV dose. Our results demonstrate that RRIG is safe and efficacious as a candidate drug to replace rabies immunoglobulin in post-exposure prophylaxis.

  11. Assessment of simple colorimetric procedures to determine smoking status of diabetic subjects.

    PubMed

    Smith, R F; Mather, H M; Ellard, G A

    1998-02-01

    The performance of a simple colorimetric assay for urinary nicotine metabolites to assess smoking status in diabetic subjects (n = 251) was investigated. Several variations of the colorimetric assay and a qualitative extraction procedure were evaluated in comparison with a cotinine immunoassay as the "gold standard." Among these, the best overall performance was achieved with the qualitative test (sensitivity 95%; specificity 100%). The quantitative measurement of total nicotine metabolites performed less well (sensitivity 92%; specificity 97%) but could be improved by incorporating a blank extraction (sensitivity 98%; specificity 98%). Allowance for diuresis appeared to offer no advantage over the other methods. These results support previous findings regarding the use of these colorimetric procedures in nondiabetic subjects and, contrary to other recent observations, their performance was not impaired in diabetic patients.

  12. Evaluating Factor XIII Specificity for Glutamine-Containing Substrates Using a MALDI-TOF Mass Spectrometry Assay

    PubMed Central

    Doiphode, Prakash G.; Malovichko, Marina V.; Mouapi, Kelly Njine; Maurer, Muriel C.

    2014-01-01

    Activated Factor XIII (FXIIIa) catalyzes the formation of γ-glutamyl-ε-lysyl cross-links within the fibrin blood clot network. Although several cross-linking targets have been identified, the characteristic features that define FXIIIa substrate specificity are not well understood. To learn more about how FXIIIa selects its targets, a matrix-assisted laser desorption ionization – time of flight mass spectrometry (MALDI-TOF MS) based assay was developed that could directly follow the consumption of a glutamine-containing substrate and the formation of a cross-linked product with glycine ethylester. This FXIIIa kinetics assay is no longer reliant on a secondary coupled reaction, on substrate labeling, or on detecting the final deacylation portion of the transglutaminase reaction. With the MALDI-TOF MS assay, glutamine-containing peptides derived from α2-antiplasmin, S. Aureus fibronectin binding protein A, and thrombin activatable fibrinolysis inhibitor were examined directly. Results suggest that the FXIIIa active site surface responds to changes in substrate residues following the reactive glutamine. The P-1 substrate position is sensitive to charge character and the P-2 and P-3 to the broad FXIIIa substrate specificity pockets. The more distant P-8 to P-11 region serves as a secondary substrate anchoring point. New knowledge on FXIIIa specificity may be used to design better substrates or inhibitors of this transglutaminase. PMID:24751466

  13. Comparison of electron microscopy, ELISA, real time RT-PCR and insulated isothermal RT-PCR for the detection of Rotavirus group A (RVA) in feces of different animal species.

    PubMed

    Soltan, Mohamed A; Tsai, Yun-Long; Lee, Pei-Yu A; Tsai, Chuan-Fu; Chang, Hsiao-Fen G; Wang, Hwa-Tang T; Wilkes, Rebecca P

    2016-09-01

    There is no gold standard for detection of Rotavirus Group A (RVA), one of the main causes of diarrhea in neonatal animals. Sensitive and specific real-time RT-PCR (rtRT-PCR) assays are available for RVA but require submission of the clinical samples to diagnostic laboratories. Patient-side immunoassays for RVA protein detection have shown variable results, particularly with samples from unintended species. A sensitive and specific test for detection of RVA on the farm would facilitate rapid management decisions. The insulated isothermal RT-PCR (RT-iiPCR) assay works in a portable machine to allow sensitive and specific on-site testing. The aim of this investigation was to evaluate a commercially available RT-iiPCR assay for RVA detection in feces from different animal species. This assay was compared to an in-house rtRT-PCR assay and a commercially available rtRT-PCR kit, as well as an ELISA and EM for RVA detection. All three PCR assays targeted the well-conserved NSP5 gene. Clinical fecal samples from 108 diarrheic animals (mainly cattle and horses) were tested. The percentage of positive samples by ELISA, EM, in-house rtRT-PCR, commercial rtRT-PCR, and RT-iiPCR was 29.4%, 31%, 36.7%, 51.4%, 56.9%, respectively. The agreement between different assays was high (81.3-100%) in samples containing high viral loads. The sensitivity of the RT-iiPCR assay appeared to be higher than the commercially available rtRT-PCR assay, with a limit of detection (95% confidence index) of 3-4 copies of in vitro transcribed dsRNA. In conclusion, the user-friendly, field-deployable RT-iiPCR system holds substantial promise for on-site detection of RVA. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  14. SYBR green-based one step quantitative real-time polymerase chain reaction assay for the detection of Zika virus in field-caught mosquitoes.

    PubMed

    Tien, Wei-Ping; Lim, Gareth; Yeo, Gladys; Chiang, Suzanna Nicole; Chong, Chee-Seng; Ng, Lee-Ching; Hapuarachchi, Hapuarachchige Chanditha

    2017-09-19

    The monitoring of vectors is one of the key surveillance measures to assess the risk of arbovirus transmission and the success of control strategies in endemic regions. The recent re-emergence of Zika virus (ZIKV) in the tropics, including Singapore, emphasizes the need to develop cost-effective, rapid and accurate assays to monitor the virus spread by mosquitoes. As ZIKV infections largely remain asymptomatic, early detection of ZIKV in the field-caught mosquitoes enables timely implementation of appropriate mosquito control measures. We developed a rapid, sensitive and specific real-time reverse transcription polymerase chain reaction (rRT-PCR) assay for the detection of ZIKV in field-caught mosquitoes. The primers and PCR cycling conditions were optimized to minimize non-specific amplification due to cross-reactivity with the genomic material of Aedes aegypti, Aedes albopictus, Culex quinquefasciatus, Culex tritaeniorhynchus, Culex sitiens and Anopheles sinensis, as well as accompanying microbiota. The performance of the assay was further evaluated with a panel of flaviviruses and alphaviruses as well as in field-caught Ae. aegypti mosquitoes confirmed to be positive for ZIKV. As compared to a probe-based assay, the newly developed assay demonstrated 100% specificity and comparable detection sensitivity for ZIKV in mosquitoes. Being a SYBR Green-based method, the newly-developed assay is cost-effective and easy to adapt, thus is applicable to large-scale vector surveillance activities in endemic countries, including those with limited resources and expertise. The amplicon size (119 bp) also allows sequencing to confirm the virus type. The primers flank relatively conserved regions of ZIKV genome, so that, the assay is able to detect genetically diverse ZIKV strains. Our findings, therefore, testify the potential use of the newly-developed assay in vector surveillance programmes for ZIKV in endemic regions.

  15. Rapid and sensitive approach to simultaneous detection of genomes of hepatitis A, B, C, D and E viruses.

    PubMed

    Kodani, Maja; Mixson-Hayden, Tonya; Drobeniuc, Jan; Kamili, Saleem

    2014-10-01

    Five viruses have been etiologically associated with viral hepatitis. Nucleic acid testing (NAT) remains the gold standard for diagnosis of viremic stages of infection. NAT methodologies have been developed for all hepatitis viruses; however, a NAT-based assay that can simultaneously detect all five viruses is not available. We designed TaqMan card-based assays for detection of HAV RNA, HBV DNA, HCV RNA, HDV RNA and HEV RNA. The performances of individual assays were evaluated on TaqMan Array Cards (TAC) for detecting five viral genomes simultaneously. Sensitivity and specificity were determined by testing 329 NAT-tested clinical specimens. All NAT-positive samples for HCV (n = 32), HDV (n = 28) and HEV (n = 14) were also found positive in TAC (sensitivity, 100%). Forty-three of 46 HAV-NAT positive samples were also positive in TAC (sensitivity, 94%), while 36 of 39 HBV-NAT positive samples were positive (sensitivity, 92%). No false-positives were detected for HBV (n = 32), HCV (n = 36), HDV (n = 30), and HEV (n = 31) NAT-negative samples (specificity 100%), while 38 of 41 HAV-NAT negative samples were negative by TAC (specificity 93%). TAC assay was concordant with corresponding individual NATs for hepatitis A-E viral genomes and can be used for their detection simultaneously. The TAC assay has potential for use in hepatitis surveillance, for screening of donor specimens and in outbreak situations. Wider availability of TAC-ready assays may allow for customized assays, for improving acute jaundice surveillance and for other purposes for which there is need to identify multiple pathogens rapidly. Published by Elsevier B.V.

  16. Viral Load Criteria and Threshold Optimization to Improve HIV Incidence Assay Characteristics - A CEPHIA Analysis

    PubMed Central

    Kassanjee, Reshma; Pilcher, Christopher D; Busch, Michael P; Murphy, Gary; Facente, Shelley N; Keating, Sheila M; Mckinney, Elaine; Marson, Kara; Price, Matthew A; Martin, Jeffrey N; Little, Susan J; Hecht, Frederick M; Kallas, Esper G; Welte, Alex

    2016-01-01

    Objective Assays for classifying HIV infections as ‘recent’ or ‘non-recent’ for incidence surveillance fail to simultaneously achieve large mean durations of ‘recent’ infection (MDRIs) and low ‘false-recent’ rates (FRRs), particularly in virally suppressed persons. The potential for optimizing recent infection testing algorithms (RITAs), by introducing viral load criteria and tuning thresholds used to dichotomize quantitative measures, is explored. Design The Consortium for the Evaluation and Performance of HIV Incidence Assays characterized over 2000 possible RITAs constructed from seven assays (LAg, BED, Less-sensitive Vitros, Vitros Avidity, BioRad Avidity, Architect Avidity and Geenius) applied to 2500 diverse specimens. Methods MDRIs were estimated using regression, and FRRs as observed ‘recent’ proportions, in various specimen sets. Context-specific FRRs were estimated for hypothetical scenarios. FRRs were made directly comparable by constructing RITAs with the same MDRI through the tuning of thresholds. RITA utility was summarized by the precision of incidence estimation. Results All assays produce high FRRs amongst treated subjects and elite controllers (10%-80%). Viral load testing reduces FRRs, but diminishes MDRIs. Context-specific FRRs vary substantially by scenario – BioRad Avidity and LAg provided the lowest FRRs and highest incidence precision in scenarios considered. Conclusions The introduction of a low viral load threshold provides crucial improvements in RITAs. However, it does not eliminate non-zero FRRs, and MDRIs must be consistently estimated. The tuning of thresholds is essential for comparing and optimizing the use of assays. The translation of directly measured FRRs into context-specific FRRs critically affects their magnitudes and our understanding of the utility of assays. PMID:27454561

  17. Development and validation of a clinical trial patient stratification assay that interrogates 27 mutation sites in MAPK pathway genes.

    PubMed

    Chang, Ken C N; Galuska, Stefan; Weiner, Russell; Marton, Matthew J

    2013-01-01

    Somatic mutations identified on genes related to the cancer-developing signaling pathways have drawn attention in the field of personalized medicine in recent years. Treatments developed to target a specific signaling pathway may not be effective when tumor activating mutations occur downstream of the target and bypass the targeted mechanism. For instance, mutations detected in KRAS/BRAF/NRAS genes can lead to EGFR-independent intracellular signaling pathway activation. Most patients with these mutations do not respond well to anti-EGFR treatment. In an effort to detect various mutations in FFPE tissue samples among multiple solid tumor types for patient stratification many mutation assays were evaluated. Since there were more than 30 specific mutations among three targeted RAS/RAF oncogenes that could activate MAPK pathway genes, a custom designed Single Nucleotide Primer Extension (SNPE) multiplexing mutation assay was developed and analytically validated as a clinical trial assay. Throughout the process of developing and validating the assay we overcame many technical challenges which include: the designing of PCR primers for FFPE tumor tissue samples versus normal blood samples, designing of probes for detecting consecutive nucleotide double mutations, the kinetics and thermodynamics aspects of probes competition among themselves and against target PCR templates, as well as validating an assay when positive control tumor tissue or cell lines with specific mutations are not available. We used Next Generation sequencing to resolve discordant calls between the SNPE mutation assay and Sanger sequencing. We also applied a triplicate rule to reduce potential false positives and false negatives, and proposed special considerations including pre-define a cut-off percentage for detecting very low mutant copies in the wild-type DNA background.

  18. Development and Application of Loop-Mediated Isothermal Amplification Assays for Rapid Visual Detection of cry2Ab and cry3A Genes in Genetically-Modified Crops

    PubMed Central

    Li, Feiwu; Yan, Wei; Long, Likun; Qi, Xing; Li, Congcong; Zhang, Shihong

    2014-01-01

    The cry2Ab and cry3A genes are two of the most important insect-resistant exogenous genes and had been widely used in genetically-modified crops. To develop more effective alternatives for the quick identification of genetically-modified organisms (GMOs) containing these genes, a rapid and visual loop-mediated isothermal amplification (LAMP) method to detect the cry2Ab and cry3A genes is described in this study. The LAMP assay can be finished within 60 min at an isothermal condition of 63 °C. The derived LAMP products can be obtained by a real-time turbidimeter via monitoring the white turbidity or directly observed by the naked eye through adding SYBR Green I dye. The specificity of the LAMP assay was determined by analyzing thirteen insect-resistant genetically-modified (GM) crop events with different Bt genes. Furthermore, the sensitivity of the LAMP assay was evaluated by diluting the template genomic DNA. Results showed that the limit of detection of the established LAMP assays was approximately five copies of haploid genomic DNA, about five-fold greater than that of conventional PCR assays. All of the results indicated that this established rapid and visual LAMP assay was quick, accurate and cost effective, with high specificity and sensitivity. In addition, this method does not need specific expensive instruments or facilities, which can provide a simpler and quicker approach to detecting the cry2Ab and cry3A genes in GM crops, especially for on-site, large-scale test purposes in the field. PMID:25167136

  19. Development and application of loop-mediated isothermal amplification assays for rapid visual detection of cry2Ab and cry3A genes in genetically-modified crops.

    PubMed

    Li, Feiwu; Yan, Wei; Long, Likun; Qi, Xing; Li, Congcong; Zhang, Shihong

    2014-08-27

    The cry2Ab and cry3A genes are two of the most important insect-resistant exogenous genes and had been widely used in genetically-modified crops. To develop more effective alternatives for the quick identification of genetically-modified organisms (GMOs) containing these genes, a rapid and visual loop-mediated isothermal amplification (LAMP) method to detect the cry2Ab and cry3A genes is described in this study. The LAMP assay can be finished within 60 min at an isothermal condition of 63 °C. The derived LAMP products can be obtained by a real-time turbidimeter via monitoring the white turbidity or directly observed by the naked eye through adding SYBR Green I dye. The specificity of the LAMP assay was determined by analyzing thirteen insect-resistant genetically-modified (GM) crop events with different Bt genes. Furthermore, the sensitivity of the LAMP assay was evaluated by diluting the template genomic DNA. Results showed that the limit of detection of the established LAMP assays was approximately five copies of haploid genomic DNA, about five-fold greater than that of conventional PCR assays. All of the results indicated that this established rapid and visual LAMP assay was quick, accurate and cost effective, with high specificity and sensitivity. In addition, this method does not need specific expensive instruments or facilities, which can provide a simpler and quicker approach to detecting the cry2Ab and cry3A genes in GM crops, especially for on-site, large-scale test purposes in the field.

  20. Comparative study of indirect immunofluorescence, enzyme-linked immunosorbent assay, and the Tzanck smear test for the diagnosis of pemphigus.

    PubMed

    Zhou, Tingting; Fang, Siyue; Li, Chunlei; Hua, Hong

    2016-11-01

    Pemphigus is one of the potentially fatal autoimmune blistering diseases. An early and accurate diagnosis is important for prognosis and therapy. It may be difficult to diagnosis based on clinical grounds alone. Direct and indirect immunofluorescence, enzyme-linked immunosorbent assay, the Tzanck smear test, or histopathology are all available for the diagnosis of pemphigus. However, there are no generally accepted diagnostic criteria for the diagnosis of this condition at present. To evaluate the diagnostic value of indirect immunofluorescence, enzyme-linked immunosorbent assay, and the Tzanck smear test for the diagnosis of pemphigus in dental clinics. A single-center retrospective study was conducted, and the clinical data of 33 patients with pemphigus and 61 controls were collected and analyzed from the Department of Oral Medicine, Peking University School of Stomatology, during 2010-2014. The sensitivities and specificities of indirect immunofluorescence, enzyme-linked immunosorbent assay, and the Tzanck smear test were calculated and compared in two groups. Sensitivities for the Tzanck smear test, indirect immunofluorescence, and enzyme-linked immunosorbent assay were 96.7%, 84.8%, and 84.8%, respectively, whereas the specificities of these tests were 60%, 91.8%, and 96.7%, respectively. The serial tests for the Tzanck smear test and enzyme-linked immunosorbent assay showed 82% sensitivity and 98.7% specificity. The serial test for the Tzanck smear test and enzyme-linked immunosorbent assay may represent a simple, rapid, and reliable way to definitive diagnosis of pemphigus. It is recommended as a common test for the diagnosis of pemphigus in dental clinics. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Evaluation of a Commercial Glycoprotein Enzyme-Linked Immunosorbent Assay for Measuring Vaccine Immunity to Varicella

    PubMed Central

    Kim, Yun Hwa; Hwang, Ji Young; Shim, Hye Min; Lee, Eunsil; Park, Songyong

    2014-01-01

    Purpose To evaluate a recently marketed commercial glycoprotein enzyme-linked immunosorbent assay (gpEIA) kit, the VaccZyme™ VZV gpEIA, for measuring the immunity of varicella-vaccinated children. Materials and Methods We investigated the accuracy and reproducibility of the VaccZyme™ VZV gpEIA kit for the detection of antibodies to VZV. We also examined the sensitivity, specificity, and correlation between antibody titers calculated with gpEIA versus fluorescent antibody to membrane antigen (FAMA) by using sera of 349 children, ranging from 1 to 6 years old. Results VaccZyme™ VZV gpEIA gave precise and reproducible intra- and inter-assay results. FAMA and gpEIA titers showed a linear correlation (Pearson correlation coefficient=0.987). The sensitivity and specificity of the VaccZyme™ gpEIA was 31.4% and 100%, respectively, when the guidelines of the gpEIA (<100 mIU/mL) and FAMA 1:4 were adopted as cutoff values. However, the maximum sensitivity and specificity were 88.9% and 95.1%, respectively, with the highest correlation (κ=0.840), if the cutoff values were set with gpEIA at 49.7 mIU/mL and FAMA 1:16. Conclusion These results demonstrate that the VaccZyme™ VZV gpEIA kit gave precise and reproducible data for measuring antibody titer after varicella vaccination. The results also showed that the antibody titer calculated with the VaccZyme™ gpEIA kit strongly correlated with the FAMA titer. However, cutoff values should be re-optimized for the evaluation of vaccine immunity. PMID:24532518

  2. Optimization of digital droplet polymerase chain reaction for quantification of genetically modified organisms

    PubMed Central

    Gerdes, Lars; Iwobi, Azuka; Busch, Ulrich; Pecoraro, Sven

    2016-01-01

    Digital PCR in droplets (ddPCR) is an emerging method for more and more applications in DNA (and RNA) analysis. Special requirements when establishing ddPCR for analysis of genetically modified organisms (GMO) in a laboratory include the choice between validated official qPCR methods and the optimization of these assays for a ddPCR format. Differentiation between droplets with positive reaction and negative droplets, that is setting of an appropriate threshold, can be crucial for a correct measurement. This holds true in particular when independent transgene and plant-specific reference gene copy numbers have to be combined to determine the content of GM material in a sample. Droplets which show fluorescent units ranging between those of explicit positive and negative droplets are called ‘rain’. Signals of such droplets can hinder analysis and the correct setting of a threshold. In this manuscript, a computer-based algorithm has been carefully designed to evaluate assay performance and facilitate objective criteria for assay optimization. Optimized assays in return minimize the impact of rain on ddPCR analysis. We developed an Excel based ‘experience matrix’ that reflects the assay parameters of GMO ddPCR tests performed in our laboratory. Parameters considered include singleplex/duplex ddPCR, assay volume, thermal cycler, probe manufacturer, oligonucleotide concentration, annealing/elongation temperature, and a droplet separation evaluation. We additionally propose an objective droplet separation value which is based on both absolute fluorescence signal distance of positive and negative droplet populations and the variation within these droplet populations. The proposed performance classification in the experience matrix can be used for a rating of different assays for the same GMO target, thus enabling employment of the best suited assay parameters. Main optimization parameters include annealing/extension temperature and oligonucleotide concentrations. The droplet separation value allows for easy and reproducible assay performance evaluation. The combination of separation value with the experience matrix simplifies the choice of adequate assay parameters for a given GMO event. PMID:27077048

  3. Optimization of digital droplet polymerase chain reaction for quantification of genetically modified organisms.

    PubMed

    Gerdes, Lars; Iwobi, Azuka; Busch, Ulrich; Pecoraro, Sven

    2016-03-01

    Digital PCR in droplets (ddPCR) is an emerging method for more and more applications in DNA (and RNA) analysis. Special requirements when establishing ddPCR for analysis of genetically modified organisms (GMO) in a laboratory include the choice between validated official qPCR methods and the optimization of these assays for a ddPCR format. Differentiation between droplets with positive reaction and negative droplets, that is setting of an appropriate threshold, can be crucial for a correct measurement. This holds true in particular when independent transgene and plant-specific reference gene copy numbers have to be combined to determine the content of GM material in a sample. Droplets which show fluorescent units ranging between those of explicit positive and negative droplets are called 'rain'. Signals of such droplets can hinder analysis and the correct setting of a threshold. In this manuscript, a computer-based algorithm has been carefully designed to evaluate assay performance and facilitate objective criteria for assay optimization. Optimized assays in return minimize the impact of rain on ddPCR analysis. We developed an Excel based 'experience matrix' that reflects the assay parameters of GMO ddPCR tests performed in our laboratory. Parameters considered include singleplex/duplex ddPCR, assay volume, thermal cycler, probe manufacturer, oligonucleotide concentration, annealing/elongation temperature, and a droplet separation evaluation. We additionally propose an objective droplet separation value which is based on both absolute fluorescence signal distance of positive and negative droplet populations and the variation within these droplet populations. The proposed performance classification in the experience matrix can be used for a rating of different assays for the same GMO target, thus enabling employment of the best suited assay parameters. Main optimization parameters include annealing/extension temperature and oligonucleotide concentrations. The droplet separation value allows for easy and reproducible assay performance evaluation. The combination of separation value with the experience matrix simplifies the choice of adequate assay parameters for a given GMO event.

  4. Validation and clinical application of a nested PCR for paracoccidioidomycosis diagnosis in clinical samples from Colombian patients.

    PubMed

    Gaviria, Marcela; Rivera, Vanessa; Muñoz-Cadavid, Cesar; Cano, Luz Elena; Naranjo, Tonny Williams

    2015-01-01

    Paracoccidioidomycosis is a systemic and endemic mycosis, restricted to tropical and subtropical areas of Latin America. The infection is caused by the thermal dimorphic fungus Paracoccidioides brasiliensis and Paracoccidioides lutzii. The diagnosis of paracoccidioidomycosis is usually performed by microscopic examination, culture and immunodiagnostic tests to respiratory specimens, body fluids and/or biopsies; however these methods require laboratory personnel with experience and several days to produce a result. In the present study, we have validated and evaluated a nested PCR assay targeting the gene encoding the Paracoccidioides gp43 membrane protein in 191 clinical samples: 115 samples from patients with proven infections other than paracoccidioidomycosis, 51 samples as negative controls, and 25 samples from patients diagnosed with paracoccidioidomycosis. Additionally, the specificity of the nested PCR assay was also evaluated using purified DNA isolated from cultures of different microorganisms (n=35) previously identified by culture and/or sequencing. The results showed that in our hands, this nested PCR assay for gp43 protein showed specificity and sensitivity rates of 100%. The optimized nested PCR conditions in our laboratory allowed detection down to 1fg of P. brasiliensis DNA. Copyright © 2015 Elsevier Editora Ltda. All rights reserved.

  5. An in vitro comparative study of the antioxidant activity and SIRT1 modulation of natural compounds.

    PubMed

    Fusi, Jonathan; Bianchi, Sara; Daniele, Simona; Pellegrini, Silvia; Martini, Claudia; Galetta, Fabio; Giovannini, Luca; Franzoni, Ferdinando

    2018-05-01

    Oxidative stress arises from an imbalance between the production of free radicals and antioxidant defences. Several studies have suggested that dietary antioxidants (such as polyphenols and berberine) may counteract oxidative stress through the involvement of the Sirtuin 1/Adenosine Monophosphate-Activated Protein Kinase (SIRT1/AMPK) pathway. The aim of this study was to evaluate the direct and specific antioxidant activity of some natural compounds, as well as their ability to modulate the expression of SIRT1 and the activation of AMPK. Quercetin, tyrosol, ferulic acid, catechin, berberine and curcumin were evaluated for their specific and direct antioxidant activity with TOSC assay. Their ability to modulate SIRT1 and AMPK was assessed by immunoblotting assay, while their cytotoxicity by CellTiter-Blue Cell Viability Assay. No statistically significant decrease (p > 0.05) in the number of viable cells was found upon challenging with the natural compounds. Quercetin exhibited the highest antioxidant activity against peroxyl radical and peroxinitrate derivates, while curcumin showed the best anti-hydroxyl activity with respect to the other compounds and, most importantly, respect to the reference antioxidants. Finally, all the tested compounds significantly increased the SIRT1 expression and the activation of AMPK. Our results clearly disclose the specific antioxidant activity of these natural compounds and their ability to increase SIRT1 expression and AMPK activation. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  6. Development and Evaluation of a Rapid and Sensitive EBOV-RPA Test for Rapid Diagnosis of Ebola Virus Disease.

    PubMed

    Yang, Mingjuan; Ke, Yuehua; Wang, Xuesong; Ren, Hang; Liu, Wei; Lu, Huijun; Zhang, Wenyi; Liu, Shiwei; Chang, Guohui; Tian, Shuguang; Wang, Lihua; Huang, Liuyu; Liu, Chao; Yang, Ruifu; Chen, Zeliang

    2016-06-01

    Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5-99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9-100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of <34, which accounted for 95.59% of the samples, was 100%. Discordant samples positive by RT-PCR but negative by EBOV-RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.

  7. Purification and Characterization of a Mucin Specific Mycelial Lectin from Aspergillus gorakhpurensis: Application for Mitogenic and Antimicrobial Activity

    PubMed Central

    Singh, Ram Sarup; Kaur, Hemant Preet; Singh, Jatinder

    2014-01-01

    Background Lectins are carbohydrate binding proteins or glycoproteins that bind reversibly to specific carbohydrates present on the apposing cells, which are responsible for their ability to agglutinate red blood cells, lymphocytes, fibroblasts, etc. Interest in lectins has been intensified due to their carbohydrate specificity as they can be valuable reagents for the investigation of cell surface sugars, purification and characterization of glycoproteins. The present study reports the purification, characterization and evaluation of mitogenic and antimicrobial potential of a mycelial lectin from Aspergillus gorakhpurensis. Methods Affinity chromatography on mucin-sepharose column was carried out for purification of Aspergillus gorakhpurensis lectin. The lectin was characterized for physico-chemical parameters. Mitogenic potential of the lectin was evaluated against splenocytes of Swiss albino mice by MTT assay. Antimicrobial activity of the purified lectin has also been evaluated by disc diffusion assay. Results Single-step affinity purification resulted in 18.6-fold purification of the mycelial lectin. The molecular mass of the lectin was found to be 70 kDa and it was composed of two subunits of 34.8 kDa as determined by gel filtration chromatography, SDS-PAGE and MALDI-TOF analysis. pH optima of the lectin was found to be 6.5–9.5, while optimum temperature for lectin activity was 20–30°C. Lectin was stable within a pH range of 7.0–10.5 and showed fair thermostability. EDTA did not affect lectin activity whereas it was found susceptible to the denaturants tested. MTT assay revealed strong mitogenic potential of A. gorakhpurensis lectin at a concentration upto 150 µg/mL. Antimicrobial activity assay showed its potent antibacterial activity against Bacillus cereus, Staphylococcous aureus and Escherichia coli and marginal antifungal activity against Saccharomyces cerevisiae. Conclusion This is the first report on the mitogenic and antimicrobial potential of Aspergillus gorakhpurensis lectin. The results will provide useful guidelines for further research in clinical applications of this lectin. PMID:25286160

  8. Purification and characterization of a mucin specific mycelial lectin from Aspergillus gorakhpurensis: application for mitogenic and antimicrobial activity.

    PubMed

    Singh, Ram Sarup; Kaur, Hemant Preet; Singh, Jatinder

    2014-01-01

    Lectins are carbohydrate binding proteins or glycoproteins that bind reversibly to specific carbohydrates present on the apposing cells, which are responsible for their ability to agglutinate red blood cells, lymphocytes, fibroblasts, etc. Interest in lectins has been intensified due to their carbohydrate specificity as they can be valuable reagents for the investigation of cell surface sugars, purification and characterization of glycoproteins. The present study reports the purification, characterization and evaluation of mitogenic and antimicrobial potential of a mycelial lectin from Aspergillus gorakhpurensis. Affinity chromatography on mucin-sepharose column was carried out for purification of Aspergillus gorakhpurensis lectin. The lectin was characterized for physico-chemical parameters. Mitogenic potential of the lectin was evaluated against splenocytes of Swiss albino mice by MTT assay. Antimicrobial activity of the purified lectin has also been evaluated by disc diffusion assay. Single-step affinity purification resulted in 18.6-fold purification of the mycelial lectin. The molecular mass of the lectin was found to be 70 kDa and it was composed of two subunits of 34.8 kDa as determined by gel filtration chromatography, SDS-PAGE and MALDI-TOF analysis. pH optima of the lectin was found to be 6.5-9.5, while optimum temperature for lectin activity was 20-30 °C. Lectin was stable within a pH range of 7.0-10.5 and showed fair thermostability. EDTA did not affect lectin activity whereas it was found susceptible to the denaturants tested. MTT assay revealed strong mitogenic potential of A. gorakhpurensis lectin at a concentration upto 150 µg/mL. Antimicrobial activity assay showed its potent antibacterial activity against Bacillus cereus, Staphylococcous aureus and Escherichia coli and marginal antifungal activity against Saccharomyces cerevisiae. This is the first report on the mitogenic and antimicrobial potential of Aspergillus gorakhpurensis lectin. The results will provide useful guidelines for further research in clinical applications of this lectin.

  9. Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

    PubMed Central

    Pinsky, Benjamin A.; Sahoo, Malaya K.; Sandlund, Johanna; Kleman, Marika; Kulkarni, Medha; Grufman, Per; Nygren, Malin; Kwiatkowski, Robert; Baron, Ellen Jo; Tenover, Fred; Denison, Blake; Higuchi, Russell; Van Atta, Reuel; Beer, Neil Reginald; Carrillo, Alda Celena; Naraghi-Arani, Pejman; Mire, Chad E.; Ranadheera, Charlene; Grolla, Allen; Lagerqvist, Nina; Persing, David H.

    2015-01-01

    Background The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Methods and Findings This study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay, the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. Conclusion In summary, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection is critical. PMID:26562786

  10. Development and Evaluation of a Quantitative PCR Assay Targeting Sandhill Crane (Grus canadensis) Fecal Pollution

    PubMed Central

    Ryu, Hodon; Lu, Jingrang; Vogel, Jason; Elk, Michael; Chávez-Ramírez, Felipe; Ashbolt, Nicholas

    2012-01-01

    While the microbial water quality in the Platte River is seasonally impacted by excreta from migrating cranes, there are no methods available to study crane fecal contamination. Here we characterized microbial populations in crane feces using phylogenetic analysis of 16S rRNA gene fecal clone libraries. Using these sequences, a novel crane quantitative PCR (Crane1) assay was developed, and its applicability as a microbial source tracking (MST) assay was evaluated by determining its host specificity and detection ability in environmental waters. Bacteria from crane excreta were dominated by bacilli and proteobacteria, with a notable paucity of sequences homologous to Bacteroidetes and Clostridia. The Crane1 marker targeted a dominant clade of unclassified Lactobacillales sequences closely related to Catellicoccus marimammalium. The host distribution of the Crane1 marker was relatively high, being positive for 69% (66/96) of the crane excreta samples tested. The assay also showed high host specificity, with 95% of the nontarget fecal samples (i.e., n = 553; 20 different free-range hosts) being negative. Of the presumed crane-impacted water samples (n = 16), 88% were positive for the Crane1 assay, whereas none of the water samples not impacted by cranes were positive (n = 165). Bayesian statistical models of the Crane1 MST marker demonstrated high confidence in detecting true-positive signals and a low probability of false-negative signals from environmental water samples. Altogether, these data suggest that the newly developed marker could be used in environmental monitoring studies to study crane fecal pollution dynamics. PMID:22492437

  11. Variola virus-specific diagnostic assays: characterization, sensitivity, and specificity.

    PubMed

    Kondas, Ashley V; Olson, Victoria A; Li, Yu; Abel, Jason; Laker, Miriam; Rose, Laura; Wilkins, Kimberly; Turner, Jonathan; Kline, Richard; Damon, Inger K

    2015-04-01

    A public health response relies upon rapid and reliable confirmation of disease by diagnostic assays. Here, we detail the design and validation of two variola virus-specific real-time PCR assays, since previous assays cross-reacted with newly identified cowpox viruses. The assay specificity must continually be reassessed as other closely related viruses are identified. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  12. Evaluation of the C.Diff Quik Chek Complete Assay, a new glutamate dehydrogenase and A/B toxin combination lateral flow assay for use in rapid, simple diagnosis of clostridium difficile disease.

    PubMed

    Sharp, Susan E; Ruden, Lila O; Pohl, Julie C; Hatcher, Patricia A; Jayne, Linda M; Ivie, W Michael

    2010-06-01

    The diagnosis of Clostridium difficile infection continues to be a challenge for many clinical microbiology laboratories. A new lateral flow assay, the C.Diff Quik Chek Complete assay, which tests for the presence of both glutamate dehydrogenase (GDH) and C. difficile toxins A and B, was evaluated for its ability to diagnose C. difficile disease. The results of this assay were compared to those of both PCR and toxigenic culture. The results showed that this assay allows 88% of specimens to be accurately screened as either positive (both tests positive) or negative (both tests negative) for the presence of toxigenic C. difficile in less than 30 min and with minimal hands-on time. Use of a random-access PCR for the analysis of specimens with discrepant results (one test positive and the other negative) allows the easy, rapid, and highly sensitive (100%; 95% confidence interval [CI], 89.6 to 100%) and specific (99.6%; 95% CI, 97.3 to 99.9%) diagnosis of C. difficile disease. The use of this algorithm would save institutional costs, curtail unnecessary isolation days, reduce the nosocomial transmission of disease, and increase the quality of care for patients.

  13. Evaluation of the C.Diff Quik Chek Complete Assay, a New Glutamate Dehydrogenase and A/B Toxin Combination Lateral Flow Assay for Use in Rapid, Simple Diagnosis of Clostridium difficile Disease▿

    PubMed Central

    Sharp, Susan E.; Ruden, Lila O.; Pohl, Julie C.; Hatcher, Patricia A.; Jayne, Linda M.; Ivie, W. Michael

    2010-01-01

    The diagnosis of Clostridium difficile infection continues to be a challenge for many clinical microbiology laboratories. A new lateral flow assay, the C.Diff Quik Chek Complete assay, which tests for the presence of both glutamate dehydrogenase (GDH) and C. difficile toxins A and B, was evaluated for its ability to diagnose C. difficile disease. The results of this assay were compared to those of both PCR and toxigenic culture. The results showed that this assay allows 88% of specimens to be accurately screened as either positive (both tests positive) or negative (both tests negative) for the presence of toxigenic C. difficile in less than 30 min and with minimal hands-on time. Use of a random-access PCR for the analysis of specimens with discrepant results (one test positive and the other negative) allows the easy, rapid, and highly sensitive (100%; 95% confidence interval [CI], 89.6 to 100%) and specific (99.6%; 95% CI, 97.3 to 99.9%) diagnosis of C. difficile disease. The use of this algorithm would save institutional costs, curtail unnecessary isolation days, reduce the nosocomial transmission of disease, and increase the quality of care for patients. PMID:20375230

  14. Comparative analytical evaluation of the respiratory TaqMan Array Card with real-time PCR and commercial multi-pathogen assays.

    PubMed

    Harvey, John J; Chester, Stephanie; Burke, Stephen A; Ansbro, Marisela; Aden, Tricia; Gose, Remedios; Sciulli, Rebecca; Bai, Jing; DesJardin, Lucy; Benfer, Jeffrey L; Hall, Joshua; Smole, Sandra; Doan, Kimberly; Popowich, Michael D; St George, Kirsten; Quinlan, Tammy; Halse, Tanya A; Li, Zhen; Pérez-Osorio, Ailyn C; Glover, William A; Russell, Denny; Reisdorf, Erik; Whyte, Thomas; Whitaker, Brett; Hatcher, Cynthia; Srinivasan, Velusamy; Tatti, Kathleen; Tondella, Maria Lucia; Wang, Xin; Winchell, Jonas M; Mayer, Leonard W; Jernigan, Daniel; Mawle, Alison C

    2016-02-01

    In this study, a multicenter evaluation of the Life Technologies TaqMan(®) Array Card (TAC) with 21 custom viral and bacterial respiratory assays was performed on the Applied Biosystems ViiA™ 7 Real-Time PCR System. The goal of the study was to demonstrate the analytical performance of this platform when compared to identical individual pathogen specific laboratory developed tests (LDTs) designed at the Centers for Disease Control and Prevention (CDC), equivalent LDTs provided by state public health laboratories, or to three different commercial multi-respiratory panels. CDC and Association of Public Health Laboratories (APHL) LDTs had similar analytical sensitivities for viral pathogens, while several of the bacterial pathogen APHL LDTs demonstrated sensitivities one log higher than the corresponding CDC LDT. When compared to CDC LDTs, TAC assays were generally one to two logs less sensitive depending on the site performing the analysis. Finally, TAC assays were generally more sensitive than their counterparts in three different commercial multi-respiratory panels. TAC technology allows users to spot customized assays and design TAC layout, simplify assay setup, conserve specimen, dramatically reduce contamination potential, and as demonstrated in this study, analyze multiple samples in parallel with good reproducibility between instruments and operators. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Clinical and Analytical Performance of the Onclarity HPV Assay Using the VALGENT Framework

    PubMed Central

    Geraets, D. T.; Moore, C.; Quint, W.; Duvall, E.; Arbyn, M.

    2015-01-01

    As the demand for human papillomavirus (HPV)-related cervical screening increases, emerging HPV tests must be evaluated robustly using well-annotated samples, such as those generated in the Validation of HPV Genotyping Tests (VALGENT) framework. Through VALGENT, we assessed the performance of the BD Onclarity HPV assay, which detects 14 high-risk (HR) types and resolves six individual types and three groups of types. Consecutive samples from a screening population (n = 1,000), enriched with cytologically abnormal samples (n = 300), that had been tested previously with the GP5+/6+ PCR enzyme immunoassay (EIA) and the GP5+/6+ PCR LMNX assay (Diassay) were tested with the Onclarity assay. Type-specific HPV prevalences were analyzed according to age and cytological result. The accuracy of the Onclarity assay for the detection of cervical intraepithelial neoplasia grade 2+ (CIN2+) and CIN3+ was assessed relative to the GP5+/6+ EIA results by using noninferiority criteria. Overall agreement and type-specific agreement between the Onclarity assay and the GP5+/6+ LMNX assay were assessed. The prevalence of HPV types 16, 18, 31, and 45 increased with the severity of cytological results (P for trend, <0.05). For the detection of CIN2+, the Onclarity assay had a relative sensitivity of 1.02 (95% confidence interval [CI], 0.99 to 1.05; P < 0.001 for noninferiority) and a relative specificity of 0.99 (95% CI, 0.97 to 1.00; P = 0.186 for noninferiority). The kappa for agreement between the Onclarity assay and the GP5+/6+ LMNX assay for HR-HPV was 0.92 (95% CI, 0.89 to 0.94), and values for the six individual types ranged from 0.78 (95% CI, 0.68 to 0.87) for HPV-52 to 0.96 (95% CI, 0.93 to 0.99) for HPV-16. These data suggest that the Onclarity assay offers applications for clinical workstreams while providing genotyping information that may be useful for risk stratification beyond types 16 and 18. PMID:26246482

  16. Evaluation of lot-to-lot repeatability and effect of assay media choice in the recombinant Factor C assay.

    PubMed

    McKenzie, Jennifer Helen; Alwis, K Udeni; Sordillo, Joanne E; Kalluri, Kesava Srinivas; Milton, Donald Kirby

    2011-06-01

    Measurement of environmental endotoxin exposures is complicated by variability encountered using current biological assay methods arising in part from lot-to-lot variability of the Limulus-amebocyte lysate (LAL) reagents. Therefore, we investigated the lot-to-lot repeatability of commercially available recombinant Factor C (rFC) kits as an alternative to LAL. Specifically, we compared endotoxin estimates obtained from rFC assay of twenty indoor dust samples, using four different extraction and assay media, to endotoxin estimates previously obtained by Limulus amebocyte lysate (LAL) assay and amounts of 3-hydroxy fatty acids (3-OHFA) in lipopolysaccharide (LPS) using gas-chromatography mass spectroscopy (GC-MS). We found that lot-to-lot variability of the rFC assay kits does not significantly alter endotoxin estimates in house dust samples when performed using three of the four assay media tested and that choice of assay media significantly altered endotoxin estimates obtained by rFC assay of house dust samples. Our findings demonstrate lot-to-lot reproducibility of rFC assay of environmental samples and suggest that use of rFC assay performed with Tris buffer or water as the extraction and assay medium for measurement of endotoxin in dust samples may be a suitable choice for developing a standardized methodology.

  17. Development and evaluation of a competitive ELISA using a monoclonal antibody for antibody detection after goose parvovirus virus-like particles (VLPs) and vaccine immunization in goose sera.

    PubMed

    Wang, Qian; Ju, Huanyu; Li, Yanwei; Jing, Zhiqiang; Guo, Lu; Zhao, Yu; Ma, Bo; Gao, Mingchun; Zhang, Wenlong; Wang, Junwei

    2014-12-01

    An assay protocol based on a monoclonal antibody-based competitive enzyme-linked immunosorbent assay (MAb-based C-ELISA) for detecting antibodies against goose parvovirus (GPV) and its virus-like particles (VLPs) is described. The assay was developed using baculovirus-expressed recombinant VP2 virus-like particles (rVP2-VLPs) as antigens and a monoclonal antibody against GPV as the competitive antibody. Of the four anti-GPV MAbs that were screened, MAb 1G3 was selected as it was blocked by the GPV positive serum. Based on the distribution of percent inhibition (PI) of the known negative sera (n=225), a cut-off value was set at 36% inhibition. Using this cut-off value, the sensitivity of the assay was 93.3% and the specificity was 95.8%, as compared with the gold standard (virus neutralization assay). The rVP2-VLPs did not react with anti-sera to other goose pathogens, indicating that it is specific for the recognization of goose parvovirus antibodies. The assay was then validated with serum samples from goslings vaccinated with several VLPs (rVP1-VLPs, rVP2-VLPs, rVP3-VLPs, and rCGV-VLPs) and other vaccines (inactivated and attenuated). The C-ELISA described in this study is a sensitive and specific diagnostic test and should have wide applications for the sero-diagnosis and immunologic surveillance of GPV. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Rapid polymerase chain reaction-based screening assay for bacterial biothreat agents.

    PubMed

    Yang, Samuel; Rothman, Richard E; Hardick, Justin; Kuroki, Marcos; Hardick, Andrew; Doshi, Vishal; Ramachandran, Padmini; Gaydos, Charlotte A

    2008-04-01

    To design and evaluate a rapid polymerase chain reaction (PCR)-based assay for detecting Eubacteria and performing early screening for selected Class A biothreat bacterial pathogens. The authors designed a two-step PCR-based algorithm consisting of an initial broad-based universal detection step, followed by specific pathogen identification targeted for identification of the Class A bacterial biothreat agents. A region in the bacterial 16S rRNA gene containing a highly variable sequence flanked by clusters of conserved sequences was chosen as the target for the PCR assay design. A previously described highly conserved region located within the 16S rRNA amplicon was selected as the universal probe (UniProbe, Integrated DNA Technology, Coralville, IA). Pathogen-specific TaqMan probes were designed for Bacillus anthracis, Yersinia pestis, and Francisella tularensis. Performance of the assay was assessed using genomic DNA extracted from the aforementioned biothreat-related organisms (inactivated or surrogate) and other common bacteria. The UniProbe detected the presence of all tested Eubacteria (31/31) with high analytical sensitivity. The biothreat-specific probes accurately identified organisms down to the closely related species and genus level, but were unable to discriminate between very close surrogates, such as Yersinia philomiragia and Bacillus cereus. A simple, two-step PCR-based assay proved capable of both universal bacterial detection and identification of select Class A bacterial biothreat and biothreat-related pathogens. Although this assay requires confirmatory testing for definitive species identification, the method has great potential for use in ED-based settings for rapid diagnosis in cases of suspected Category A bacterial biothreat agents.

  19. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis.

    PubMed

    Urabe, Naohisa; Sakamoto, Susumu; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-06-01

    We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. Copyright © 2017 American Society for Microbiology.

  20. A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay.

    PubMed

    Bartels, Mette Damkjaer; Boye, Kit; Rohde, Susanne Mie; Larsen, Anders Rhod; Torfs, Herbert; Bouchy, Peggy; Skov, Robert; Westh, Henrik

    2009-05-01

    Rapid tests for detection of methicillin-resistant Staphylococcus aureus (MRSA) carriage are important to limit the transmission of MRSA in the health care setting. We evaluated the performance of the BD GeneOhm MRSA real-time PCR assay using a diverse collection of MRSA isolates, mainly from Copenhagen, Denmark, but also including international isolates, e.g., USA100-1100. Pure cultures of 349 MRSA isolates representing variants of staphylococcal cassette chromosome mec (SCCmec) types I to V and 103 different staphylococcal protein A (spa) types were tested. In addition, 53 methicillin-susceptible Staphylococcus aureus isolates were included as negative controls. Forty-four MRSA isolates were undetectable; of these, 95% harbored SCCmec type IVa, and these included the most-common clone in Copenhagen, spa t024-sequence type 8-IVa. The false-negative MRSA isolates were tested with new primers (analyte-specific reagent [ASR] BD GeneOhm MRSA assay) supplied by Becton Dickinson (BD). The ASR BD GeneOhm MRSA assay detected 42 of the 44 isolates that were false negative in the BD GeneOhm MRSA assay. Combining the BD GeneOhm MRSA assay with the ASR BD GeneOhm MRSA assay greatly improved the results, with only two MRSA isolates being false negative. The BD GeneOhm MRSA assay alone is not adequate for MRSA detection in Copenhagen, Denmark, as more than one-third of our MRSA isolates would not be detected. We recommend that the BD GeneOhm MRSA assay be evaluated against the local MRSA diversity before being established as a standard assay, and due to the constant evolution of SCCmec cassettes, a continuous global surveillance is advisable in order to update the assay as necessary.

Top