10 CFR 963.16 - Postclosure suitability evaluation method.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Postclosure suitability evaluation method. 963.16 Section... Determination, Methods, and Criteria § 963.16 Postclosure suitability evaluation method. (a) DOE will evaluate postclosure suitability using the total system performance assessment method. DOE will conduct a total system...
10 CFR 963.16 - Postclosure suitability evaluation method.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Postclosure suitability evaluation method. 963.16 Section... Determination, Methods, and Criteria § 963.16 Postclosure suitability evaluation method. (a) DOE will evaluate postclosure suitability using the total system performance assessment method. DOE will conduct a total system...
10 CFR 963.16 - Postclosure suitability evaluation method.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Postclosure suitability evaluation method. 963.16 Section... Determination, Methods, and Criteria § 963.16 Postclosure suitability evaluation method. (a) DOE will evaluate postclosure suitability using the total system performance assessment method. DOE will conduct a total system...
Comprehensive evaluation index system of total supply capability in distribution network
NASA Astrophysics Data System (ADS)
Zhang, Linyao; Wu, Guilian; Yang, Jingyuan; Jia, Shuangrui; Zhang, Wei; Sun, Weiqing
2018-01-01
Aiming at the lack of a comprehensive evaluation of the distribution network, based on the existing distribution network evaluation index system, combined with the basic principles of constructing the evaluation index, put forward a new evaluation index system of distribution network capacity. This paper is mainly based on the total supply capability of the distribution network, combining single index and various factors, into a multi-evaluation index of the distribution network, thus forming a reasonable index system, and various indicators of rational quantification make the evaluation results more intuitive. In order to have a comprehensive judgment of distribution network, this paper uses weights to analyse the importance of each index, verify the rationality of the index system through the example, it is proved that the rationality of the index system, so as to guide the direction of distribution network planning.
Hey, Christiane; Pluschinski, Petra; Stanschus, Soenke; Euler, Harald A.; Sader, Robert A.; Langmore, Susan; Neumann, Katrin
2011-01-01
A properly performed fiberoptic endoscopic evaluation of swallowing (FEES®) is comprehensive and time-consuming. Editing times of FEES protocols and attempts for efficiency maximization are unknown. Here, the protocol editing times of completed FEES examinations were determined. The present study reports the time savings and quality gains of a newly developed documentation system tailored to the FEES standard of Langmore. Four independent examiners analyzed twelve videos of FEES procedures, six without and six with the documentation system. Effectiveness of the documentation system was evaluated according to the times for total evaluation, interpretation, documentation, report writing, and for report completeness. The documentation system reduced editing times and increased report completeness with large effect sizes. Averaged total evaluation time decreased from 42 to 27 min, report completeness increased from 55 to 80%. The use of the documentation system facilitates and improves the assessment of the swallowing process. PMID:20938202
Performability evaluation of the SIFT computer
NASA Technical Reports Server (NTRS)
Meyer, J. F.; Furchtgott, D. G.; Wu, L. T.
1979-01-01
Performability modeling and evaluation techniques are applied to the SIFT computer as it might operate in the computational evironment of an air transport mission. User-visible performance of the total system (SIFT plus its environment) is modeled as a random variable taking values in a set of levels of accomplishment. These levels are defined in terms of four attributes of total system behavior: safety, no change in mission profile, no operational penalties, and no economic process whose states describe the internal structure of SIFT as well as relavant conditions of the environment. Base model state trajectories are related to accomplishment levels via a capability function which is formulated in terms of a 3-level model hierarchy. Performability evaluation algorithms are then applied to determine the performability of the total system for various choices of computer and environment parameter values. Numerical results of those evaluations are presented and, in conclusion, some implications of this effort are discussed.
da Silva Fernandes, Meg; Sanches Lima, Fernando; Rodrigues, Daniele; Handa, Cintia; Guelfi, Marcela; Garcia, Sandra; Ida, Elza Iouko
2017-08-15
This study aimed to evaluate the isoflavone and total phenolic contents in kefir-fermented soymilk storage and after the in vitro digestive system simulation (DSS). Soymilk was fermented with kefir culture (0.02UC/L) at 25°C for 15h and stored at 4°C for 4days. After the fermentation and storage, the isoflavone and total phenolic contents were quantified by high performance liquid chromatography and spectrophotometry, respectively. The cell viability of lactic acid bacteria and yeast was evaluated. Fermentation promoted an increase of approximately 3log CFU/g cycles of the microorganisms and the storage process did not alter the aglycone isoflavones and total phenolic contents. The content of aglycone isoflavones increased 2-fold, and the total phenolic content increased 9-fold. Therefore, kefir-fermented soymilk is a good source of aglycone isoflavones and phenolics, since the content of these substances was increased significantly after the in vitro digestive system simulation of the product. Copyright © 2017 Elsevier Ltd. All rights reserved.
Total main rotor isolation system analysis
NASA Technical Reports Server (NTRS)
Sankewitsch, V.
1981-01-01
Requirements, preliminary design, and verification procedures for a total main rotor isolation system at n/rev are presented. The fuselage is isolated from the vibration inducing main rotor at one frequency in all degrees of freedom by four antiresonant isolation units. Effects of parametric variations on isolation system performance are evaluated.
An Evaluation of Online Help for the NOTIS OPAC.
ERIC Educational Resources Information Center
White, Frank
1994-01-01
Discussion of online help systems in online public access catalogs (OPACs) focuses on a study that evaluated the online help system for the NOTIS (Northwestern Online Total Integrated System) OPAC. Features of the system reviewed include online functions; training features; general interface features; access points; and message content and display…
NASA Astrophysics Data System (ADS)
Hwang, J.; Lee, K.; Jang, R.; Jeon, S.
2018-04-01
The environmental impact assessment system and the environmental plan for the preservation of the land environment are carried out with the aim of preventing damage to the environment caused by human activities, improving the quality of life and creating a pleasant environment. However, despite these various systems, the natural resources have been continuously damaged, and the system to cope with them has been advanced, but there has been a limit to fully conserve natural resources from development. The total amount of natural resources is being promoted as a part of the purpose of supplementing the system, but the evaluation method of the total amount of natural resources suitable for domestic situation is not presented yet. Natural resources are diverse and complicated in their categories and elements, and their measurement units are also diverse, making it difficult to synthesize them into one unit. Therefore, in this study, we proposed a method to calculate the total amount by using the evaluation map of the Environmental Conservation Value Assessment Map (ECVAM) which derives the final achievement with 5 grades using 65 evaluation items. However, we consistently applied the weight twice as much as the grade and did not utilize any information other than the map of ECVAM. The results of this study can be applied to the Total Natural Resources Management System through follow-up study such as application of various environmental information and weighting method.
Evaluation of the wind pumped hydropower storage integrated flood mitigation system
NASA Astrophysics Data System (ADS)
Safi, Aishah; Basrawi, Firdaus
2018-04-01
As Wind Pumped Hydropower Storage (WPHS) need high cost to construct, it is important to study their impacts on economic and environmental aspects. Thus, this research aims to evaluate their economic and environmental performances. First, Hybrid Optimization Model for Electric Renewable (HOMER) was used to simulate power generation system with and without the flood reservoir. Next, the total amount of emitted air pollutant was used to evaluate the environmental impacts. It was found the wind-diesel with reservoir storage system (A-III) will have much lower NPC than other systems that do not include reservoir for flood mitigation when the cost of flood losses are included in the total Net Present Cost (NPC). The NPC for system A-III was RM 1.52 million and for diesel standalone system (A-I) is RM 10.8 million when the cost of flood losses are included in the total NPC. Between both energy systems, the amount of pollutants emitted by the A-III system was only 408 kg-CO2/year which is much less than the A-I system which is 99, 754 kg of carbon dioxide per year. To conclude, the WPHS integrated with flood mitigation system seems promising in the aspects of economic and environment.
Hospital employs TQM principles to rework its evaluation system.
Burda, D
1992-02-24
One Kansas hospital has taken the traditional employee evaluation process--with all its performance criteria, point systems and rankings--and turned it on its head. The new system employs total quality management principles and promotes personal development, education and teamwork. And everyone gets the same raise.
Soft-light overhead illumination systems improve laparoscopic task performance.
Takai, Akihiro; Takada, Yasutsugu; Motomura, Hideki; Teramukai, Satoshi
2014-02-01
The aim of this study was to evaluate the impact of attached shadow cues for laparoscopic task performance. We developed a soft-light overhead illumination system (SOIS) that produced attached shadows on objects. We compared results using the SOIS with those using a conventional illumination system with regard to laparoscopic experience and laparoscope-to-target distances (LTDs). Forty-two medical students and 23 surgeons participated in the study. A peg transfer task (LTD, 120 mm) for students and surgeons, and a suture removal task (LTD, 30 mm) for students were performed. Illumination systems were randomly assigned to each task. Endpoints were: total number of peg transfers; percentage of peg-dropping errors; and total execution time for suture removal. After the task, participants filled out a questionnaire on their preference for a particular illumination system. Total number of peg transfers was greater with the SOIS for both students and surgeons. Percentage of peg-dropping errors for surgeons was lower with the SOIS. Total execution time for suture removal was shorter with the SOIS. Forty-five participants (69% in total) evaluated the SOIS for easier task performance. The present results confirm that the SOIS improves laparoscopic task performance, regardless of previous laparoscopic experience or LTD.
Solar energy system economic evaluation: Contemporary Newman, Georgia
NASA Technical Reports Server (NTRS)
1980-01-01
An economic evaluation of performance of the solar energy system (based on life cycle costs versus energy savings) for five cities considered to be representative of a broad range of environmental and economic conditions in the United States is discussed. The considered life cycle costs are: hardware, installation, maintenance, and operating costs for the solar unique components of the total system. The total system takes into consideration long term average environmental conditions, loads, fuel costs, and other economic factors applicable in each of five cities. Selection criteria are based on availability of long term weather data, heating degree days, cold water supply temperature, solar insolation, utility rates, market potential, and type of solar system.
Solar energy system economic evaluation: Contemporary Newman, Georgia
NASA Astrophysics Data System (ADS)
1980-09-01
An economic evaluation of performance of the solar energy system (based on life cycle costs versus energy savings) for five cities considered to be representative of a broad range of environmental and economic conditions in the United States is discussed. The considered life cycle costs are: hardware, installation, maintenance, and operating costs for the solar unique components of the total system. The total system takes into consideration long term average environmental conditions, loads, fuel costs, and other economic factors applicable in each of five cities. Selection criteria are based on availability of long term weather data, heating degree days, cold water supply temperature, solar insolation, utility rates, market potential, and type of solar system.
Yambe, T; Hashimoto, H; Kobayashi, S; Sonobe, T; Naganuma, S; Nanka, S S; Matsuki, H; Yoshizawa, M; Tabayashi, K; Takayasu, H; Takeda, H; Nitta, S
1997-01-01
We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.
ERIC Educational Resources Information Center
Cooper, Brian J.
2012-01-01
Teaching evaluation systems are an important part of the total evaluation of faculty in geography departments in the United States. As demands for accountability for teaching effectiveness continue to emerge from many groups, it has become increasingly important for geography departments to develop systems that not only provide teaching…
Evaluation of total energy-rate feedback for glidescope tracking in wind shear
NASA Technical Reports Server (NTRS)
Belcastro, C. M.; Ostroff, A. J.
1986-01-01
Low-altitude wind shear is recognized as an infrequent but significant hazard to all aircraft during take-off and landing. A total energy-rate sensor, which is potentially applicable to this problem, has been developed for measuring specific total energy-rate of an airplane with respect to the air mass. This paper presents control system designs, with and without energy-rate feedback, for the approach to landing of a transport airplane through severe wind shear and gusts to evaluate application of this sensor. A system model is developed which incorporates wind shear dynamics equations with the airplance equations of motion, thus allowing the control systems to be analyzed under various wind shears. The control systems are designed using optimal output feedback and are analyzed using frequency domain control theory techniques. Control system performance is evaluated using a complete nonlinear simulation of the airplane and a severe wind shear and gust data package. The analysis and simulation results indicate very similar stability and performance characteristics for the two designs. An implementation technique for distributing the velocity gains between airspeed and ground speed in the simulation is also presented, and this technique is shown to improve the performance characteristics of both designs.
NASA Technical Reports Server (NTRS)
Bruce, Kevin R.
1988-01-01
An integrated autopilot/autothrottle system was designed using a total energy control design philosophy. This design ensures that the system can differentiate between maneuvers requiring a change in thrust to accomplish a net energy change, and those maneuvers which only require elevator control to redistribute energy. The system design, the development of the system, and a summary of simulation results are defined.
Reliability studies of Integrated Modular Engine system designs
NASA Technical Reports Server (NTRS)
Hardy, Terry L.; Rapp, Douglas C.
1993-01-01
A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.
Reliability studies of integrated modular engine system designs
NASA Technical Reports Server (NTRS)
Hardy, Terry L.; Rapp, Douglas C.
1993-01-01
A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.
Reliability studies of integrated modular engine system designs
NASA Astrophysics Data System (ADS)
Hardy, Terry L.; Rapp, Douglas C.
1993-06-01
A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.
Reliability studies of Integrated Modular Engine system designs
NASA Astrophysics Data System (ADS)
Hardy, Terry L.; Rapp, Douglas C.
1993-06-01
A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.
Solar energy system performance evaluation: Seasonal report for Fern Lansing, Lansing, Michigan
NASA Technical Reports Server (NTRS)
1980-01-01
A solar space heating and hot water system's operational performance from April 1979 through March 1980 is evaluated. Solar energy satisfied 15 percent of the total measured load (hot water plus space heating). Net savings were approximately 21 million BTUs.
Flight evaluation of a simple total energy-rate system with potential wind-shear application
NASA Technical Reports Server (NTRS)
Ostroff, A. J.; Hueschen, R. M.; Hellbaum, R. F.; Creedon, J. F.
1981-01-01
Wind shears can create havoc during aircraft terminal area operations and have been cited as the primary cause of several major aircraft accidents. A simple sensor, potentially having application to the wind-shear problem, was developed to rapidly measure aircraft total energy relative to the air mass. Combining this sensor with either a variometer or a rate-of-climb indicator provides a total energy-rate system which was successfully applied in soaring flight. The measured rate of change of aircraft energy can potentially be used on display/control systems of powered aircraft to reduce glide-slope deviations caused by wind shear. The experimental flight configuration and evaluations of the energy-rate system are described. Two mathematical models are developed: the first describes operation of the energy probe in a linear design region and the second model is for the nonlinear region. The calculated total rate is compared with measured signals for many different flight tests. Time history plots show the tow curves to be almost the same for the linear operating region and very close for the nonlinear region.
Impact of production systems on swine confinement buildings bioaerosols.
Létourneau, Valérie; Nehmé, Benjamin; Mériaux, Anne; Massé, Daniel; Duchaine, Caroline
2010-02-01
Hog production has been substantially intensified in Eastern Canada. Hogs are now fattened in swine confinement buildings with controlled ventilation systems and high animal densities. Newly designed buildings are equipped with conventional manure handling and management systems, shallow or deep litter systems, or source separation systems to manage the large volumes of waste. However, the impacts of those alternative production systems on bioaerosol concentrations within the barns have never been evaluated. Bioaerosols were characterized in 18 modern swine confinement buildings, and the differences in bioaerosol composition in the three different production systems were evaluated. Total dust, endotoxins, culturable actinomycetes, fungi, and bacteria were collected with various apparatuses. The total DNA of the air samples was extracted, and quantitative polymerase chain reaction (PCR) was used to assess the total number of bacterial genomes, as a total (culturable and nonculturable) bacterial assessment. The measured total dust and endotoxin concentrations were not statistically different in the three studied production systems. In buildings with sawdust beds, actinomycetes and molds were found in higher concentrations than in the conventional barns. Aspergillus, Cladosporium, Penicillium, and Scopulariopsis species were identified in all the studied swine confinement buildings. A. flavus, A. terreus, and A. versicolor were abundantly present in the facilities with sawdust beds. Thermotolerant A. fumigatus and Mucor were usually found in all the buildings. The culturable bacteria concentrations were higher in the barns with litters than in the conventional buildings, while real-time PCR revealed nonstatistically different concentrations of total bacteria in all the studied swine confinement buildings. In terms of workers' respiratory health, barns equipped with a solid/liquid separation system may offer better air quality than conventional buildings or barns with sawdust beds. The impact of ventilation rates, air distribution, or building design still has to be explored.
Evaluation of the SafeLane overlay system for crash reduction on bridge deck surfaces.
DOT National Transportation Integrated Search
2010-03-01
The winter performance of the SafeLane commercial overlay system has been evaluated at four installations on : bridge decks in the state of Minnesota. The study was conducted over a period of a total of three years. Analyses : included mechanical ...
Chronic ovine evaluation of a totally implantable electrical left ventricular assist system.
Ramasamy, N; Chen, H; Miller, P J; Jassawalla, J S; Greene, B A; Ocampo, A; Siegel, L C; Oyer, P E; Portner, P M
1989-01-01
The totally implantable Novacor left ventricular assist system (LVAS) comprises a pump/drive unit (VAD), electronic control and power subsystem (ECP), variable volume compensator (VVC), and belt skin transformer (BST). The system is now undergoing chronic in vivo evaluation. Cumulative animal testing of VAD, VVC, and BST subsystems are 12.1, 4.9, and 43 years, respectively. The longest implants were 279 days for the VAD, 767 days for the VVC, and 1,148 days for the BST. A chronic implant of the total system was electively terminated at 260 days. The LVAS was powered via the BST. Continuously monitored hemodynamic and pump parameters have demonstrated normal hemodynamics and LVAS operation. Periodic VVC determinations suggest a 0.8 ml/day diffusive gas loss. Tether-free operation has been demonstrated with an Ag-Zn battery backpack. The animal was healthy and free of infection as indicated by routine hematologic, biochemical and serum enzyme determinations. Hemolysis is minimal (plasma free hemoglobin less than 5 mg%). Pump output ranged from 7 to 8 L/min. Severe valve calcification was the reason for elective termination at 260 days. This preclinical in vivo experience, and in vitro reliability studies, demonstrate efficacy of the total system.
Duda, Scott; Kandiah, Sheena; Stout, Janet E; Baron, Julianne L; Yassin, Mohamed; Fabrizio, Marie; Ferrelli, Juliet; Hariri, Rahman; Wagener, Marilyn M; Goepfert, John; Bond, James; Hannigan, Joseph; Rogers, Denzil
2014-11-01
To evaluate the efficacy of a new monochloramine generation system for control of Legionella in a hospital hot water distribution system. A 495-bed tertiary care hospital in Pittsburgh, Pennsylvania. The hospital has 12 floors covering approximately 78,000 m(2). The hospital hot water system was monitored for a total of 29 months, including a 5-month baseline sampling period prior to installation of the monochloramine system and 24 months of surveillance after system installation (postdisinfection period). Water samples were collected for microbiological analysis (Legionella species, Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Acinetobacter species, nitrifying bacteria, heterotrophic plate count [HPC] bacteria, and nontuberculous mycobacteria). Chemical parameters monitored during the investigation included monochloramine, chlorine (free and total), nitrate, nitrite, total ammonia, copper, silver, lead, and pH. A significant reduction in Legionella distal site positivity was observed between the pre- and postdisinfection periods, with positivity decreasing from an average of 53% (baseline) to an average of 9% after monochloramine application (P<0.5]). Although geometric mean HPC concentrations decreased by approximately 2 log colony-forming units per milliliter during monochloramine treatment, we did not observe significant changes in other microbial populations. This is the first evaluation in the United States of a commercially available monochloramine system installed on a hospital hot water system for Legionella disinfection, and it demonstrated a significant reduction in Legionella colonization. Significant increases in microbial populations or other negative effects previously associated with monochloramine use in large municipal cold water systems were not observed.
2016-07-27
ADDRESS (ES) U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 Wireless Power Transfer , Structural Health Monitoring...efficient strongly coupled magnetic resonant systems, Wireless Power Transfer , (03 2014): 0. doi: 10.1017/wpt.2014.3 TOTAL: 1 Received Paper TOTAL...2016 Received Paper . Miniaturized Strongly Coupled Magnetic Resonant Systems for Wireless Power Transfer , 2016 IEEE Antennas Propagat. Society
NASA Technical Reports Server (NTRS)
Kaufmann, David N.; Ncnally, B. David
1995-01-01
Test flights were conducted to evaluate the capability of Differential Global Positioning System (DGPS) to provide the accuracy and integrity required for International Civil Aviation Organization (ICAO) Category (CAT) 3 precision approach and landings. These test flights were part of a Federal Aviation Administration (FAA) program to evaluate the technical feasibility of using DGPS based technology for CAT 3 precision approach and landing applications. A United Airlines Boeing 737-300 (N304UA) was equipped with DGPS receiving equipment and additional computing capability provided by Stanford University. The test flights were conducted at NASA Ames Research Center's Crows Landing Flight Facility, Crows Landing, California. The flight test evaluation was based on completing 100 approaches and autolandings; 90 touch and go, and 10 terminating with a full stop. Two types of accuracy requirements were evaluated: 1) Total system error, based on the Required Navigation Performance (RNP), and 2) Navigation sensor error, based on ICAO requirements for the Microwave Landing System (MLS). All of the approaches and autolandings were evaluated against ground truth reference data provided by a laser tracker. Analysis of these approaches and autolandings shows that the Stanford University/United Airlines system met the requirements for a successful approach and autolanding 98 out of 100 approaches and autolandings, based on the total system error requirements as specified in the FAA CAT 3 Level 2 Flight Test Plan.
Comparative treatment effectiveness of conventional trench and seepage pit systems.
Field, J P; Farrell-Poe, K L; Walworth, J L
2007-03-01
On-site wastewater treatment systems can be a potential source of groundwater contamination in regions throughout the United States and other parts of the world. Here, we evaluate four conventional trench systems and four seepage pit systems to determine the relative effectiveness of these systems for the treatment of septic tank effluent in medium- to coarse-textured arid and semiarid soils. Soil borings were advanced up to twice the depth of the trenches (4 m) and seepage pits (15 m) at two horizontal distances (30 cm and 1.5 m) from the sidewalls of the systems. Soil samples were analyzed for various biological and chemical parameters, including Escherichia coli, total coliform, pH, total organic carbon, total dissolved solids, total nitrogen, ammonium-nitrogen, and nitrate-nitrogen. Most soil parameters investigated approached background levels more rapidly near the trenches than the seepage pits, as sampling distance increased both vertically and horizontally from the sidewalls of the systems.
Solar energy system performance evaluation: Seasonal report for IBM System 1B, Carlsbad, New Mexico
NASA Technical Reports Server (NTRS)
1980-01-01
A hot solar heating and hot water system's operational performance from April 1979 through March 1980 is evaluated. The space heating and hot water loads were near expected values for the year. Solar energy provided 43 percent of the space heating and 53 percent of the hot water energy. The system did not meet the total system solar fraction design value of 69 percent because of a combination of higher estimated space heating load than was actually encountered and the apportioning of solar energy between the space heating and the domestic hot water loads. System losses and high building temperatures also contributed to this deviation. Total net savings were 23.072 million BTUs. Most of the energy savings came during the winter months, but hot water savings were sufficient to justify running the system during the summer months.
Geza, Mengistu; McCray, John E; Murray, Kyle E
2010-01-01
Nutrient loading to surface water systems has traditionally been associated with agricultural sources. Sources such as on-site wastewater systems (OWS) may be of concern especially in rural, nonagricultural watersheds. The impact of various point and nonpoint sources including OWS in Turkey Creek Watershed was evaluated using the Watershed Analysis Risk Management Framework, which was calibrated using 10 yr of observed stream flow and total P concentrations. Doubling the population in the watershed or OWS septic tank effluent P concentration increased mean stream total P concentration by a factor of 1.05. Converting all the OWS to a conventional sewer system with a removal efficiency of 93% at the wastewater treatment plant increased the mean total P concentration at the watershed outlet by a factor of 1.26. Reducing the soil adsorption capacity by 50% increased the mean stream total P concentration by a factor of 3.2. Doubling the initial P concentration increased the mean stream total P concentration by a factor of 1.96. Stream flow and sediment transport also substantially affected stream P concentration. The results suggest that OWS contribution to stream P in this watershed is minimal compared with other factors within the simulated time frame of 10 yr.
Ng, Ding-Quan; Lin, Yi-Pin
2016-01-01
In this pilot study, a modified sampling protocol was evaluated for the detection of lead contamination and locating the source of lead release in a simulated premise plumbing system with one-, three- and seven-day stagnation for a total period of 475 days. Copper pipes, stainless steel taps and brass fittings were used to assemble the “lead-free” system. Sequential sampling using 100 mL was used to detect lead contamination while that using 50 mL was used to locate the lead source. Elevated lead levels, far exceeding the World Health Organization (WHO) guideline value of 10 µg·L−1, persisted for as long as five months in the system. “Lead-free” brass fittings were identified as the source of lead contamination. Physical disturbances, such as renovation works, could cause short-term spikes in lead release. Orthophosphate was able to suppress total lead levels below 10 µg·L−1, but caused “blue water” problems. When orthophosphate addition was ceased, total lead levels began to spike within one week, implying that a continuous supply of orthophosphate was required to control total lead levels. Occasional total lead spikes were observed in one-day stagnation samples throughout the course of the experiments. PMID:26927154
Ng, Ding-Quan; Lin, Yi-Pin
2016-02-27
In this pilot study, a modified sampling protocol was evaluated for the detection of lead contamination and locating the source of lead release in a simulated premise plumbing system with one-, three- and seven-day stagnation for a total period of 475 days. Copper pipes, stainless steel taps and brass fittings were used to assemble the "lead-free" system. Sequential sampling using 100 mL was used to detect lead contamination while that using 50 mL was used to locate the lead source. Elevated lead levels, far exceeding the World Health Organization (WHO) guideline value of 10 µg · L(-1), persisted for as long as five months in the system. "Lead-free" brass fittings were identified as the source of lead contamination. Physical disturbances, such as renovation works, could cause short-term spikes in lead release. Orthophosphate was able to suppress total lead levels below 10 µg · L(-1), but caused "blue water" problems. When orthophosphate addition was ceased, total lead levels began to spike within one week, implying that a continuous supply of orthophosphate was required to control total lead levels. Occasional total lead spikes were observed in one-day stagnation samples throughout the course of the experiments.
Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.
Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W
2017-01-01
The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.
[Smoked sausages and food additives: evaluation of total mutagenic activity].
Dugan, A M; Tkacheva, D L
2011-01-01
The paper deals with the evaluation of the total mutagenic activity of samples of the inorganic and organic fractions of three technology smoked sausages (boiled-smoked, semi-smoked, and raw-smoked) and some food additives used to manufacture the above sausages. Their mild and moderate mutagenic effects were recorded in a Salmonella typhimurium bacterial test system with a metabolic activation system. Physicochemical analysis of the fractions of the smoked sausages has shown that their study samples are substantially contaminated with heavy metals and representatives of polycyclic aromatic hydrocarbons, partially causing the mutagenic effects observed.
Casino, Daniela; Martelli, Sandra; Zaffagnini, Stefano; Lopomo, Nicola; Iacono, Francesco; Bignozzi, Simone; Visani, Andrea; Marcacci, Maurilio
2009-02-01
Surgical navigation systems are currently used to guide the surgeon in the correct alignment of the implant. The aim of this study was to expand the use of navigation systems by proposing a surgical protocol for intraoperative kinematics evaluations during knee arthroplasty. The protocol was evaluated on 20 patients, half undergoing unicondylar knee arthroplasty (UKA) and half undergoing posterior-substituting, rotating-platform total knee arthroplasty (TKA). The protocol includes a simple acquisition procedure and an original elaboration methodology. Kinematic tests were performed before and after surgery and included varus/valgus stress at 0 and 30 degrees and passive range of motion. Both UKA and TKA improved varus/valgus stability in extension and preserved the total magnitude of screw-home motion during flexion. Moreover, compared to preoperative conditions, values assumed by tibial axial rotation during flexion in TKA knees were more similar to the rotating patterns of UKA knees. The analysis of the anteroposterior displacement of the knee compartments confirmed that the two prostheses did not produce medial pivoting, but achieved a postoperative normal behavior. These results demonstrated that proposed intraoperative kinematics evaluations by a navigation system provided new information on the functional outcome of the reconstruction useful to restore knee kinematics during surgery.
Dong, Zhao; Nath, Anjali; Guo, Jing; Bhaumik, Urmi; Chin, May Y; Dong, Sherry; Marshall, Erica; Murphy, Johnna S; Sandel, Megan T; Sommer, Susan J; Ursprung, W W Sanouri; Woods, Elizabeth R; Reid, Margaret; Adamkiewicz, Gary
2018-01-01
To test the applicability of the Environmental Scoring System, a quick and simple approach for quantitatively measuring environmental triggers collected during home visits, and to evaluate its contribution to improving asthma outcomes among various child asthma programs. We pooled and analyzed data from multiple child asthma programs in the Greater Boston Area, Massachusetts, collected in 2011 to 2016, to examine the association of environmental scores (ES) with measures of asthma outcomes and compare the results across programs. Our analysis showed that demographics were important contributors to variability in asthma outcomes and total ES, and largely explained the differences among programs at baseline. Among all programs in general, we found that asthma outcomes were significantly improved and total ES significantly reduced over visits, with the total Asthma Control Test score negatively associated with total ES. Our study demonstrated that the Environmental Scoring System is a useful tool for measuring home asthma triggers and can be applied regardless of program and survey designs, and that demographics of the target population may influence the improvement in asthma outcomes.
Optimizing the physical ergonomics indices for the use of partial pressure suits.
Ding, Li; Li, Xianxue; Hedge, Alan; Hu, Huimin; Feathers, David; Qin, Zhifeng; Xiao, Huajun; Xue, Lihao; Zhou, Qianxiang
2015-03-01
This study developed an ergonomic evaluation system for the design of high-altitude partial pressure suits (PPSs). A total of twenty-one Chinese males participated in the experiment which tested three types of ergonomics indices (manipulative mission, operational reach and operational strength) were studied using a three-dimensional video-based motion capture system, a target-pointing board, a hand dynamometer, and a step-tread apparatus. In total, 36 ergonomics indices were evaluated and optimized using regression and fitting analysis. Some indices that were found to be linearly related and redundant were removed from the study. An optimal ergonomics index system was established that can be used to conveniently and quickly evaluate the performance of different pressurized/non-pressurized suit designs. The resulting ergonomics index system will provide a theoretical basis and practical guidance for mission planners, suit designers and engineers to design equipment for human use, and to aid in assessing partial pressure suits. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Effectiveness of the United States Marine Corps Tiered Evaluation System
2015-03-01
RA Manpower and Reserve Affairs MCMAP Marine Corps Martial Arts Program MMPR Marine Corps Promotions Branch MOS military occupational specialty...STAP subsequent term alignment program TFDW Total Force Data Warehouse USMC United States Marine Corps xv THIS PAGE INTENTIONALLY LEFT BLANK...Furthermore, I would like to thank Mr. Tim Johnson at the Total Force Data Warehouse and Ms. Doreen Marucci at the Performance Evaluation Section for
Henne, Erik; Kesten, Steven; Herth, Felix J F
2013-01-01
A method of achieving endoscopic lung volume reduction for emphysema has been developed that utilizes precise amounts of thermal energy in the form of water vapor to ablate lung tissue. This study evaluates the energy output and implications of the commercial InterVapor system and compares it to the clinical trial system. Two methods of evaluating the energy output of the vapor systems were used, a direct energy measurement and a quantification of resultant thermal profile in a lung model. Direct measurement of total energy and the component attributable to gas (vapor energy) was performed by condensing vapor in a water bath and measuring the temperature and mass changes. Infrared images of a lung model were taken after vapor delivery. The images were quantified to characterize the thermal profile. The total energy and vapor energy of the InterVapor system was measured at various dose levels and compared to the clinical trial system at a dose of 10.0 cal/g. An InterVapor dose of 8.5 cal/g was found to have the most similar vapor energy output with the smallest associated reduction in total energy. This was supported by characterization of the thermal profile in the lung model that demonstrated the profile of InterVapor at 8.5 cal/g to not exceed the profile of the clinical trial system. Considering both total energy and vapor energy is important during the development of clinical vapor applications. For InterVapor, a closer study of both energy types justified a reduced target vapor-dosing range for lung volume reduction. The clinical implication is a potential improvement for benefiting the risk profile. Copyright © 2013 S. Karger AG, Basel.
Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong
2017-01-01
This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE. PMID:28273146
Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong
2017-01-01
This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE.
A Data-Driven Conceptualization of Teacher Evaluation
ERIC Educational Resources Information Center
Namaghi, Seyyed Ali Ostovar
2010-01-01
Research perspectives on teacher evaluation present evaluators with a set of possible acts. Local evaluation systems, on the other hand, specify a permissible set of acts from the total universe. The acts specified within a given locality act as conditions for teacher action. Using the sampling and analytical procedures of grounded theory, this…
Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.
2014-01-01
BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281
Initial in vitro testing of a paediatric continuous-flow total artificial heart.
Fukamachi, Kiyotaka; Karimov, Jamshid H; Horvath, David J; Sunagawa, Gengo; Byram, Nicole A; Kuban, Barry D; Moazami, Nader
2018-06-01
Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lenly J. Weathers; Lynn E. Katz
2002-05-29
The use of zero valent iron, permeable reactive barriers (PRBs) for groundwater remediation continues to increase. AN exciting variation of this technology involves introducing anaerobic bacteria into these barriers so that both biological and abiotic pollutant removal processes are functional. This work evaluated the hypothesis that a system combining a mixed culture of sulfate reducing bacteria (SRB) with zero valent iron would have a greater cr(VI) removal efficiency and a greater total Cr(VI) removal capacity than a zero valent iron system without the microorganisms. Hence, the overall goal of this research was to compare the performance of these types ofmore » systems with regard to their Cr(VI) removal efficiency and total Cr(VI) removal capacity. Both batch and continuous flow reactor systems were evaluated.« less
Strati, Paolo; Uhm, Joon H; Kaufmann, Timothy J; Nabhan, Chadi; Parikh, Sameer A; Hanson, Curtis A; Chaffee, Kari G; Call, Timothy G; Shanafelt, Tait D
2016-04-01
Abroad array of conditions can lead to neurological symptoms in chronic lymphocytic leukemia patients and distinguishing between clinically significant involvement of the central nervous system by chronic lymphocytic leukemia and symptoms due to other etiologies can be challenging. Between January 1999 and November 2014, 172 (4%) of the 4174 patients with chronic lymphocytic leukemia followed at our center had a magnetic resonance imaging of the central nervous system and/or a lumbar puncture to evaluate neurological symptoms. After comprehensive evaluation, the etiology of neurological symptoms was: central nervous system chronic lymphocytic leukemia in 18 patients (10% evaluated by imaging and/or lumbar puncture, 0.4% overall cohort); central nervous system Richter Syndrome in 15 (9% evaluated, 0.3% overall); infection in 40 (23% evaluated, 1% overall); autoimmune/inflammatory conditions in 28 (16% evaluated, 0.7% overall); other cancer in 8 (5% evaluated, 0.2% overall); and another etiology in 63 (37% evaluated, 1.5% overall). Although the sensitivity of cerebrospinal fluid analysis to detect central nervous system disease was 89%, the specificity was only 42% due to the frequent presence of leukemic cells in the cerebrospinal fluid in other conditions. No parameter on cerebrospinal fluid analysis (e.g. total nucleated cells, total lymphocyte count, chronic lymphocytic leukemia cell percentage) were able to offer a reliable discrimination between patients whose neurological symptoms were due to clinically significant central nervous system involvement by chronic lymphocytic leukemia and another etiology. Median overall survival among patients with clinically significant central nervous system chronic lymphocytic leukemia and Richter syndrome was 12 and 11 months, respectively. In conclusion, clinically significant central nervous system involvement by chronic lymphocytic leukemia is a rare condition, and neurological symptoms in patients with chronic lymphocytic leukemia are due to other etiologies in approximately 80% of cases. Analysis of the cerebrospinal fluid has high sensitivity but limited specificity to distinguish clinically significant chronic lymphocytic leukemia involvement from other etiologies. Copyright© Ferrata Storti Foundation.
Electrical Space Conditioning.
ERIC Educational Resources Information Center
General Electric Co., Cleveland, OH. Large Lamp Dept.
Integrated systems utilizing the heating potential of lighting equipment are discussed in terms of the implications for design and the methods for evaluation and control. General principles cover heat transfer, heat from lamps and luminaires, and control of lighting heat. Suggested systems include--(1) total control systems, (2) bleed-off systems,…
Intermediate load-center photovoltaic application experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burgess, E. L.
1980-01-01
A total of nine intermediate load-center photovoltaic systems were carried into the construction phase this year. These nine systems range in size from 20 to 225 kW/sub p/ electrical output and total almost 1 MW/sub p/. They are being installed in a diverse set of applications and locations and represent the bulk of the photovoltaic initial system evaluation experiments (ISEE) for the intermediate load-center sector. Each of these experiments are briefly described and the status of the construction phase is given for each project.
Fatigue evaluation of composite-reinforced, integrally stiffened metal panels
NASA Technical Reports Server (NTRS)
Dumesnil, C. E.
1973-01-01
The fatigue behavior of composite-reinforced, integrally stiffened metal panels was investigated in combined metal and composite materials subjected to fatigue loading. The systems investigated were aluminum-graphite/epoxy, and aluminum-S glass/epoxy. It was found that the composite material would support the total load at limit stress after the metal had completely failed, and the weight of the composite-metal system would be equal to that of an all metal system which would carry the same total load at limit stress.
Performance evaluation of a full-scale innovative swine waste-to-energy system.
Xu, Jiele; Adair, Charles W; Deshusses, Marc A
2016-09-01
Intensive monitoring was carried out to evaluate the performance of a full-scale innovative swine waste-to-energy system at a commercial swine farm with 8640 heads of swine. Detailed mass balances over each unit of the system showed that the system, which includes a 7600m(3) anaerobic digester, a 65-kW microturbine, and a 4200m(3) aeration basin, was able to remove up to 92% of the chemical oxygen demand (COD), 99% of the biological oxygen demand (BOD), 77% of the total nitrogen (TN), and 82% of the total phosphorous (TP) discharged into the system as fresh pig waste. The overall biogas yield based on the COD input was 64% of the maximum theoretical, a value that indicates that even greater environmental benefits could be obtained with process optimization. Overall, the characterization of the materials fluxes in the system provides a greater understanding of the fate of organics and nutrients in large scale animal waste management systems. Copyright © 2016 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Three different commercially available structural plastic media were evaluated in triplicate in moving bed toriod filters under low salinity (11-12 ppt) warm water culture conditions and two different feed loading rates. The culture system consisted of nine separate modules that include a double dra...
ERIC Educational Resources Information Center
Pease, Pamela S.; Tinsley, Patsy J.
The paper details development, implementation, and user research/evaluation of TI-IN Network, Inc., the first private, interactive satellite based educational system in the United States developed for public schools and offering a total systems approach by providing both user technology and a wide range of course offerings. An overview of specific…
Joshi, Ashish; Perin, Douglas M Puricelli; Amadi, Chioma; Trout, Kate
2015-03-05
The study purpose was to conduct heuristic evaluation of an interactive, bilingual touchscreen-enabled breastfeeding educational programme for Hispanic women living in rural settings in Nebraska. Three raters conducted the evaluation during May 2013 using principles of Nielson's heuristics. A total of 271 screens were evaluated and included: interface (n = 5), programme sections (n = 223) and educational content (n = 43). A total of 97 heuristic violations were identified and were mostly related to interface (8 violations/5 screens) and programme components (89 violations/266 screens). The most common heuristic violations reported were recognition rather than recall (62%, n = 60), consistency and standards (14%, n = 14) and match between the system and real world (9%, n = 9). Majority of the heuristic violations had minor usability issues (73%, n = 71). The only grade 4 heuristic violation reported was due to the visibility of system status in the assessment modules. The results demonstrated that the system was more consistent with Nielsen's usability heuristics. With Nielsen's usability heuristics, it is possible to identify problems in a timely manner, and help facilitate the identification and prioritisation of problems needing urgent attention at an earlier stage before the final deployment of the system.
Basewide Engineering Evaluation-Cost Analysis for Soil Vapor Extraction. General Evaluation Document
1993-09-01
Agricultural (low density) a 3.7%/ Residential Leand McFR6 Open Space (recreational) Suron ding Solid Waste Disposal Faiiy(transfer sttin Areas 12...designed, manufactured , and sold as integrated units by vendors of SVE systems. Smaller systems, such as those with total 42 GENERAL EVALUATION...the 2,000 scfm and larger capacity range, can be supplied either as portable units (e g., on multiple trailers), or manufactured on one to three skids
Experimental optimization of the FireFly 600 photovoltaic off-grid system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyson, William Earl; Orozco, Ron; Ralph, Mark E.
2003-10-01
A comprehensive evaluation and experimental optimization of the FireFly{trademark} 600 off-grid photovoltaic system manufactured by Energia Total, Ltd. was conducted at Sandia National Laboratories in May and June of 2001. This evaluation was conducted at the request of the manufacturer and addressed performance of individual system components, overall system functionality and performance, safety concerns, and compliance with applicable codes and standards. A primary goal of the effort was to identify areas for improvement in performance, reliability, and safety. New system test procedures were developed during the effort.
Environmental Projects for Aerospace Applications
2012-05-23
following for missile systems as part of a total hexavalent chromium free coating system: 1-Evaluate trivalent chromium pretreatment (TCP) for use on...Yourfilename.ppt Hexavalent Chromium Free Coating System for Magnesium Housings on Aviation Systems UNCLASSIFIED UNCLASSIFIED 12 Yourfilename.ppt...Sulfur Dioxide (SO2) testing complete. Hexavalent Chromium Free Coating System for Magnesium Housings on Aviation Systems Description If
South Texas Veterans Health Care System Mobile Health Clinic: Business Case Analysis
2009-06-11
purchase a mobile health unit with no ancillary services with a clinical staffing of one physician’s assistant (PA) and one nurse practitioner (NP). A...total of four options were evaluated: (1) no ancillary with physician/registered nurse (RN) staffing, (2) no ancillary with PA/NP staffing, (3) radiology...one nurse practitioner (NP). A total of four options were evaluated: (1) no ancillary with physician/registered nurse (RN) staffing, (2) no
Horwatich, J.A.; Corsi, Steven R.; Bannerman, Roger T.
2004-01-01
A pressurized stormwater filtration system was installed in 1998 as a stormwater-treatment practice to treat runoff from a hospital rooftop and parking lot in Green Bay, Wisconsin. This type of filtration system has been installed in Florida citrus groves and sewage treatment plants around the United States; however, this installation is the first of its kind to be used to treat urban runoff and the first to be tested in Wisconsin. The U.S. Geological Survey (USGS) monitored the system between November 2000 and September 2002 to evaluate it as part of the U.S. Environmental Protection Agency's Environmental Technology Verification Program. Fifteen runoff events were monitored for flow and water quality at the inlet and outlet of the system, and comparison of the event mean concentrations and constituent loads was used to evaluate its effectiveness. Loads were decreased in all particulate-associated constituents monitored, including suspended solids (83 percent), suspended sediment (81 percent), total Kjeldahl nitrogen (26 percent), total phosphorus (54 percent), and total recoverable zinc (62 percent). Total dissolved solids, dissolved phosphorus, and nitrate plus nitrite loads remained similar or increased through the system. The increase in some constituents was most likely due to a ground-water contribution between runoff events. Sand/silt split analysis resulted in the median silt content of 78 percent at the inlet, 87 percent at the outlet, and 3 percent at the flow splitter.
The use of synthetic ligaments in the design of an enhanced stability total knee joint replacement.
Stokes, Michael D; Greene, Brendan C; Pietrykowski, Luke W; Gambon, Taylor M; Bales, Caroline E; DesJardins, John D
2018-03-01
Current total knee replacement designs work to address clinically desired knee stability and range of motion through a balance of retained anatomy and added implant geometry. However, simplified implant geometries such as bearing surfaces, posts, and cams are often used to replace complex ligamentous constraints that are sacrificed during most total knee replacement procedures. This article evaluates a novel total knee replacement design that incorporates synthetic ligaments to enhance the stability of the total knee replacement system. It was hypothesized that by incorporating artificial cruciate ligaments into a total knee replacement design at specific locations and lengths, the stability of the total knee replacement could be significantly altered while maintaining active ranges of motion. The ligament attachment mechanisms used in the design were evaluated using a tensile test, and determined to have a safety factor of three with respect to expected ligamentous loading in vivo. Following initial computational modeling of possible ligament orientations, a physical prototype was constructed to verify the function of the design by performing anterior/posterior drawer tests under physiologic load. Synthetic ligament configurations were found to increase total knee replacement stability up to 94% compared to the no-ligament case, while maintaining total knee replacement flexion range of motion between 0° and 120°, indicating that a total knee replacement that incorporates synthetic ligaments with calibrated location and lengths should be able to significantly enhance and control the kinematic performance of a total knee replacement system.
NASA Technical Reports Server (NTRS)
Bodley, C. S.; Devers, A. D.; Park, A. C.; Frisch, H. P.
1978-01-01
A theoretical development and associated digital computer program system for the dynamic simulation and stability analysis of passive and actively controlled spacecraft are presented. The dynamic system (spacecraft) is modeled as an assembly of rigid and/or flexible bodies not necessarily in a topological tree configuration. The computer program system is used to investigate total system dynamic characteristics, including interaction effects between rigid and/or flexible bodies, control systems, and a wide range of environmental loadings. In addition, the program system is used for designing attitude control systems and for evaluating total dynamic system performance, including time domain response and frequency domain stability analyses.
Improved methods for venous access: the Port-A-Cath, a totally implanted catheter system.
Strum, S; McDermed, J; Korn, A; Joseph, C
1986-04-01
We prospectively evaluated the performance and rate of long-term complications with the Port-A-Cath (PAC), a totally implanted vascular access system. Two catheter styles were evaluated, a small-bore (SB) catheter (0.51-mm diameter) and a large-bore (LB) catheter (1.02-mm diameter), in conjunction with the use of a strict catheter care protocol. The PAC performed well, and with both SB and LB systems, no significant extravasation, skin necrosis, hematoma, septum damage or leakage, or subcutaneous portal infections occurred after 7,240 days of implantation and 1,435 days of use. Complications with the PAC system consisted of catheter occlusion (seven patients, 21.5%) and one instance of possible catheter infection (3.1%). Occlusions were limited to patients implanted with the SB catheter (seven of 16, 43.8%), and five of the seven (71.4%) occurred in patients receiving continuous infusion chemotherapy and/or total parenteral nutrition. Patency of the PAC system was maintained using a regular flushing schedule once every 30 days, a significant advantage compared with the daily maintenance schedule required with externally placed venous catheters. The results of this study suggest that the PAC system can provide a safe and reliable method for venous access in patients requiring intermittent or prolonged intravenous therapy.
This project evaluates a test program of a totally automated weight-based refuse disposal rate system. his test program was conducted by the City of Farmington, Minnesota between 1991 and 1993. he intent of the program was to test a mechanism which would automatically assess a fe...
Evaluation of air-displacement plethysmography for body composition assessment in preterm infants
USDA-ARS?s Scientific Manuscript database
Adiposity may contribute to the future risk of disease. The aim of this study was to evaluate the accuracy and reliability of an air-displacement plethysmography (ADP) system to estimate percentage fat mass (%FM) in preterm infants and to evaluate interdevice reliability in infants. A total of 70 pr...
First Destination Transportation Study
1978-03-03
avoidance potentials on a daily procurement basis. A "total" sys- tematic cost evaluation program, including specific de - cision rules needed on an...implementation priority :x needed. The rec- ommended priority is as follows: [ (1) Develop improved system management concepts that will "form the framework ...priority as it provides the overall framework for better system management. Cost evaluation and CCSS Enhancement Programs deserve next consideration, as
2016-02-28
centered at a point, x, where the field is to be evaluated , and the far field region Ωfar. A single unit cell located at x′ in the far field region is...successive shell adds less total error as expected because of the increased distance from evaluation point. . . . . . . . . . . . . . . . . . 108...of freedom in the system to more manageable levels. Energies or forces in the system are then evaluated through numerical quadrature rules and allow
A multiphysical ensemble system of numerical snow modelling
NASA Astrophysics Data System (ADS)
Lafaysse, Matthieu; Cluzet, Bertrand; Dumont, Marie; Lejeune, Yves; Vionnet, Vincent; Morin, Samuel
2017-05-01
Physically based multilayer snowpack models suffer from various modelling errors. To represent these errors, we built the new multiphysical ensemble system ESCROC (Ensemble System Crocus) by implementing new representations of different physical processes in the deterministic coupled multilayer ground/snowpack model SURFEX/ISBA/Crocus. This ensemble was driven and evaluated at Col de Porte (1325 m a.s.l., French alps) over 18 years with a high-quality meteorological and snow data set. A total number of 7776 simulations were evaluated separately, accounting for the uncertainties of evaluation data. The ability of the ensemble to capture the uncertainty associated to modelling errors is assessed for snow depth, snow water equivalent, bulk density, albedo and surface temperature. Different sub-ensembles of the ESCROC system were studied with probabilistic tools to compare their performance. Results show that optimal members of the ESCROC system are able to explain more than half of the total simulation errors. Integrating members with biases exceeding the range corresponding to observational uncertainty is necessary to obtain an optimal dispersion, but this issue can also be a consequence of the fact that meteorological forcing uncertainties were not accounted for. The ESCROC system promises the integration of numerical snow-modelling errors in ensemble forecasting and ensemble assimilation systems in support of avalanche hazard forecasting and other snowpack-modelling applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, Vanessa A.; Kothari, Ninad; Bhagia, Samarthya
Populus natural variants have been shown to realize a broad range of sugar yields during saccharification, however, the structural features responsible for higher sugar release from natural variants are not clear. In addition, the sugar release patterns resulting from digestion with two distinct biological systems, fungal enzymes and Clostridium thermocellum, have yet to be evaluated and compared. This study evaluates the effect of structural features of three natural variant Populus lines, which includes the line BESC standard, with respect to the overall process of sugar release for two different biological systems.
Thomas, Vanessa A.; Kothari, Ninad; Bhagia, Samarthya; ...
2017-11-30
Populus natural variants have been shown to realize a broad range of sugar yields during saccharification, however, the structural features responsible for higher sugar release from natural variants are not clear. In addition, the sugar release patterns resulting from digestion with two distinct biological systems, fungal enzymes and Clostridium thermocellum, have yet to be evaluated and compared. This study evaluates the effect of structural features of three natural variant Populus lines, which includes the line BESC standard, with respect to the overall process of sugar release for two different biological systems.
An effective CPR home learning system. A program evaluation.
Starr, L M
1998-06-01
1. Program evaluation using a self instruction CPR home learning system indicated that people could learn CPR without attending a formal class. Reported training time for adult CPR averaged 1 hour, and ease of understanding was rated 4.9 on a 5 point scale. 2. Use of a home learning system can benefit a workplace by reducing reliance on a CPR instructor, reducing total training time, and exposing families and others in the community to the learning experience. 3. This program evaluation suggests that this training methodology supports the mission of AHA, and also can meet corporate objectives.
Goebel, L; Zurakowski, D; Müller, A; Pape, D; Cucchiarini, M; Madry, H
2014-10-01
To compare the 2D and 3D MOCART system obtained with 9.4 T high-field magnetic resonance imaging (MRI) for the ex vivo analysis of osteochondral repair in a translational model and to correlate the data with semiquantitative histological analysis. Osteochondral samples representing all levels of repair (sheep medial femoral condyles; n = 38) were scanned in a 9.4 T high-field MRI. The 2D and adapted 3D MOCART systems were used for grading after point allocation to each category. Each score was correlated with corresponding reconstructions between both MOCART systems. Data were next correlated with corresponding categories of an elementary (Wakitani) and a complex (Sellers) histological scoring system as gold standards. Correlations between most 2D and 3D MOCART score categories were high, while mean total point values of 3D MOCART scores tended to be 15.8-16.1 points higher compared to the 2D MOCART scores based on a Bland-Altman analysis. "Defect fill" and "total points" of both MOCART scores correlated with corresponding categories of Wakitani and Sellers scores (all P ≤ 0.05). "Subchondral bone plate" also correlated between 3D MOCART and Sellers scores (P < 0.001). Most categories of the 2D and 3D MOCART systems correlate, while total scores were generally higher using the 3D MOCART system. Structural categories "total points" and "defect fill" can reliably be assessed by 9.4 T MRI evaluation using either system, "subchondral bone plate" using the 3D MOCART score. High-field MRI is valuable to objectively evaluate osteochondral repair in translational settings. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Soviet Railroad Troops: An Updated Review.
1980-01-01
4 Existing Soviet Transport System ........................... 4 *Scarcity of the Rail System ...basis for a totally new evaluation of the Soviet logistics system as a whole, significant misunderstanding will arise if rail capabilities are degraded...sizeable superiority in divisions, tanks, and artillery, the austere Soviet logistic system is suitable only for supporting a short war. In fact, the
Techniques to Remotely Identify and Evaluate Electrical Power System Infrastructure
2006-02-01
bursts is quantified in a “ macroburst ”: The totality of all transients (arcs) produced during a single switch opera- tion is termed a macroburst . A... macroburst can be characterized in terms of its duration in time, the total number of field transients produced, the am- plitude variation between
Flight capacity of Sitophilus zeamais Motschulsky in relation to gender and temperature
USDA-ARS?s Scientific Manuscript database
The maize weevil, Sitophilus zeamais, is a major pest of stored products worldwide. In this research, we evaluated the flight performance of S. zeamais under various temperatures using a 26-channel computer-monitored flight-mill system to estimate total flight distance (TFD), total flight duration (...
Akbas, Neval; Schryver, Patricia G; Algeciras-Schimnich, Alicia; Baumann, Nikola A; Block, Darci R; Budd, Jeffrey R; Gaston, S J Stephen; Klee, George G
2014-11-01
We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Evaluation of performance of full-scale duckweed and algal ponds receiving septage.
Papadopoulos, Frantzis H; Metaxa, Eirini G; Iatrou, Miltos N; Papadopoulos, Aristotelis H
2014-12-01
The performance of duckweed and algal systems in removing fecal bacteria, organic matter, and nutrients was evaluated in three full-scale ponds operating in series. Trucks collected septage from holding tanks and discharged it into the system, daily. The inflow rates varied between the warm and the cold season. Duckweed and algae naturally colonized the ponds in two successive periods of 10 and 13 months, respectively. Environmental conditions were determined at various pond depths. Without harvesting, the duckweed system was neutral and anoxic. Alkaline and oversaturation conditions were observed in the algal system. The overall removals of 5-day biochemical oxygen demand, total suspended solids, total nitrogen removal, and orthophosphate (ortho-PO4(3-)) ranged from 94 to 97, 62 to 84, 68 to 74, and 0 to 26%, respectively. The E. coli and enterococci reductions varied between 2.2 to 3.0 and 1.1 to 1.4 log units, respectively. The upper values were always associated with the algal system.
CDRH RF phantom for hyperthermia systems evaluations.
Allen, S; Kantor, G; Bassen, H; Ruggera, P
1988-01-01
The National Cancer Institute (NCI) sponsored clinical evaluations of investigational 'regional' hyperthermia systems at four clinical institutions. To support this project, the Center for Devices and Radiological Health (CDRH) developed a series of test instruments to evaluate the magnitude and repeatability of the induced heating by radiofrequency (RF) systems. Data from three institutions using the same model hyperthermia system have been analyzed. After heating, the average temperature from measurements taken at several points in the test phantom at each institution agree within +/- 0.002 degrees C. These differences are about equal to the measurement uncertainty. Thus, this technique can be used for preclinical evaluation and quality control of the total system operation. After one of the institutions relocated its hyperthermia system, a subsequent set of data showed inconsistencies compared to their earlier data. Investigation traced this to cable loss and power meter interference. From the analysis of the data from the three institutions, the utility of the CDRH RF phantom for hyperthermia systems evaluation is demonstrated.
Solar energy system performance evaluation: Seasonal report for Contemporary Newman, Newman, Georgia
NASA Technical Reports Server (NTRS)
1980-01-01
A hot solar heating and hot water system's operational performance from June 1979 through April 1980 is evaluated. Solar energy satisfied 42 percent of the total measure load (hot water plus space heating), which was somewhat higher than the solar fraction of 32 percent. When system losses into the heating space from duct leaks and storage are included, the heating solar fraction increases from 42 to 64 percent. Net electrical energy savings were 5.47 million BTUs.
Katam, Keerthi; Bhattacharyya, Debraj
2018-05-12
Microalgae-based treatment systems have been successfully used for the polishing of domestic wastewater. Research is underway in studying the suitability of using these systems as main treatment units. This study focuses on comparing the performances of a mixed microalgal culture and an aerobic bacterial culture, based on the kinetic evaluation, in removing organic carbon from a kitchen wastewater. The two systems were operated at six different solid retention times (SRTs)-2, 4, 6, 8, 10, and 12 days in continuous mode. The influent and effluent samples were analyzed for chemical oxygen demand (COD), total organic carbon (TOC), total nitrogen (TN), phosphates, and surfactants. Steady-state kinetics (k, K s , Y, and k d ) for organic carbon removal were obtained by fitting experimental data in linearized Michaelis-Menten and Monod equations. The mixed microalgal system showed similar or better performance in COD and TN removal (88 and 85%, respectively) when compared with the COD and TN removal by the aerobic bacterial system (89 and 48%). A maximum lipid yield of 40% (w/w of dry biomass) was observed in the microalgal system. Saturated fatty acids accounted for 50% of the total observed FAME species. The study indicates that the mixed microalgal culture is capable of treating kitchen wastewater and has the potential to replace aerobic bacteria in biological treatment systems in certain cases.
Optimized design of total energy systems: The RETE project
NASA Astrophysics Data System (ADS)
Alia, P.; Dallavalle, F.; Denard, C.; Sanson, F.; Veneziani, S.; Spagni, G.
1980-05-01
The RETE (Reggio Emilia Total Energy) project is discussed. The total energy system (TES) was developed to achieve the maximum quality matching on the thermal energy side between plant and user and perform an open scheme on the electrical energy side by connection with the Italian electrical network. The most significant qualitative considerations at the basis of the plant economic energy optimization and the selection of the operating criterion most fitting the user consumption characteristics and the external system constraints are reported. The design methodology described results in a TES that: in energy terms achieves a total efficiency evaluated on a yearly basis to be equal to about 78 percent and a fuel saving of about 28 percent and in economic terms allows a recovery of the investment required as to conventional solutions, in about seven years.
NASA Technical Reports Server (NTRS)
Knauber, R. N.
1982-01-01
This report describes a FORTRAN IV coded computer program for post-flight evaluation of a launch vehicle upper stage on-off reaction control system. Aerodynamic and thrust misalignment disturbances are computed as well as the total disturbing moments in pitch, yaw, and roll. Effective thrust misalignment angle time histories of the rocket booster motor are calculated. Disturbing moments are integrated and used to estimate the required control system total inpulse. Effective control system specific inpulse is computed for the boost and coast phases using measured control fuel useage. This method has been used for more than fifteen years for analyzing the NASA Scout launch vehicle second and third-stage reaction control system performance. The computer program is set up in FORTRAN IV for a CDC CYBER 175 system. With slight modification it can be used on other machines having a FORTRAN compiler. The program has optional CALCOMP plotting output. With this option the program requires 19K words of memory and has 786 cards. Running time on a CDC CYBER 175 system is less than three (3) seconds for a typical problem.
Validating electromagnetic walking stick rail surface crack measuring systems : final report.
DOT National Transportation Integrated Search
2016-06-01
A series of field studies were undertaken to evaluate electromagnetic walking stick systems and their ability to measure the depth : of damage from surface breaking cracks. In total, four railroads, and four suppliers participated in the project. The...
Ten-year NEDO BVAD development program: moving forward to the clinical arena.
Motomura, Tadashi; Okubo, Hisashi; Oda, Takeshi; Ogawa, Daisuke; Okahisa, Toshiya; Igo, Stephen; Shinohara, Toshiyuki; Yamamoto, Yoshiro; Noguchi, Chikaya; Ishizuka, Tsukasa; Okamoto, Eiji; Nosé, Yukihiko
2006-01-01
Since 1995, the Baylor Group has been developing a totally implantable NEDO BVAD system. This 10-year program was completed in March 2005, and preparation for clinical trials is underway. This article summarizes the entire 10-year NEDO program and describes the strategy for clinical trials. The project aimed to achieve: (1) dual centrifugal pumps with the ability of full biventricular support, (2) a compact system implantable into small adults, (3) a totally implantable system with transcutaneous energy transmission system (TETS), (4) a durable system with a lifetime of over 5 years, and (5) a system free of thrombus and with minimal hemolysis. The final goals are to complete preclinical system evaluations and commence the clinical trials in the near future. In vitro studies have demonstrated a pump capacity of over 8.5 l/min and an Index of Hemolysis of <0.004 g/100 l. The pump-bearing life expectancy was over 5 years. To date, eight pumps endured in vivo studies of over 3 months without complications, including thromboembolic events. The in vitro endurance studies of eight pumps are longer than 1 year. There were no mechanical malfunctions or pump failure. A stepwise clinical trial is being planned: Step1, a wearable BVAD/VAD will be clinically studied; Step 2, the BVAD/VAD will be implanted intracorporeally without TETS; and, Step 3, a totally implantable system will be clinically evaluated. The NEDO BVAD system has completed preclinical testing. Clinical trial preparation is underway.
International Space Station (ISS) Orbital Replaceable Unit (ORU) Wet Storage Risk Assessment
NASA Technical Reports Server (NTRS)
Squire, Michael D.; Rotter, Henry A.; Lee, Jason; Packham, Nigel; Brady, Timothy K.; Kelly, Robert; Ott, C. Mark
2014-01-01
The International Space Station (ISS) Program requested the NASA Engineering and Safety Center (NESC) to evaluate the risks posed by the practice of long-term wet storage of ISS Environmental Control and Life Support (ECLS) regeneration system orbital replacement units (ORUs). The ISS ECLS regeneration system removes water from urine and humidity condensate and converts it into potable water and oxygen. A total of 29 ORUs are in the ECLS system, each designed to be replaced by the ISS crew when necessary. The NESC assembled a team to review the ISS ECLS regeneration system and evaluate the potential for biofouling and corrosion. This document contains the outcome of the evaluation.
Applying usability heuristics to radiotherapy systems.
Chan, Alvita J; Islam, Mohammad K; Rosewall, Tara; Jaffray, David A; Easty, Anthony C; Cafazzo, Joseph A
2012-01-01
Heuristic evaluations have been used to evaluate safety of medical devices by identifying and assessing usability issues. Since radiotherapy treatment delivery systems often consist of multiple complex user-interfaces, a heuristic evaluation was conducted to assess the potential safety issues of such a system. A heuristic evaluation was conducted to evaluate the treatment delivery system at Princess Margaret Hospital (Toronto, Canada). Two independent evaluators identified usability issues with the user-interfaces and rated the severity of each issue. The evaluators identified 75 usability issues in total. Eighteen of them were rated as high severity, indicating the potential to have a major impact on patient safety. A majority of issues were found on the record and verify system, and many were associated with the patient setup process. While the hospital has processes in place to ensure patient safety, recommendations were developed to further mitigate the risks of potential consequences. Heuristic evaluation is an efficient and inexpensive method that can be successfully applied to radiotherapy delivery systems to identify usability issues and improve patient safety. Although this study was conducted only at one site, the findings may have broad implications for the design of these systems. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Patterson, John P; Markgraf, Carrie G; Cirino, Maria; Bass, Alan S
2005-01-01
A series of experiments were undertaken to evaluate the accuracy, precision, specificity, and sensitivity of an automated, infrared photo beam-based open field motor activity system, the MotorMonitor v. 4.01, Hamilton-Kinder, LLC, for use in a good laboratory practices (GLP) Safety Pharmacology laboratory. This evaluation consisted of two phases: (1) system validation, employing known inputs using the EM-100 Controller Photo Beam Validation System, a robotically controlled vehicle representing a rodent and (2) biologic validation, employing groups of rats treated with the standard pharmacologic agents diazepam or D-amphetamine. The MotorMonitor's parameters that described the open-field activity of a subject were: basic movements, total distance, fine movements, x/y horizontal ambulations, rearing, and total rest time. These measurements were evaluated over a number of zones within each enclosure. System validation with the EM-100 Controller Photo Beam Validation System showed that all the parameters accurately and precisely measured what they were intended to measure, with the exception of fine movements and x/y ambulations. Biologic validation using the central nervous system depressant diazepam at 1, 2, or 5 mg/kg, i.p. produced the expected dose-dependent reduction in rat motor activity. In contrast, the central nervous system stimulant D-amphetamine produced the expected increases in rat motor activity at 0.1 and 1 mg/kg, i.p, demonstrating the specificity and sensitivity of the system. Taken together, these studies of the accuracy, precision, specificity, and sensitivity show the importance of both system and biologic validation in the evaluation of an automated open field motor activity system for use in a GLP compliant laboratory.
USDA-ARS?s Scientific Manuscript database
Soil organic C and N are important indicators of agricultural sustainability, yet numerous field studies have revealed a multitude of responses in the extent and rate of change imposed by conservation management, and therefore, a lack of clarity on responses. We conducted an evaluation of total and...
DOT National Transportation Integrated Search
1982-03-01
The Systems Analysis Research Unit at the Civil Aeromedical Institute (CAMI) has developed a generic model for Federal Aviation Administration (FAA) Academy training program evaluation. The model will serve as a basis for integrating the total data b...
Professional Growth & Support Spending Calculator
ERIC Educational Resources Information Center
Education Resource Strategies, 2013
2013-01-01
This "Professional Growth & Support Spending Calculator" helps school systems quantify all current spending aimed at improving teaching effectiveness. Part I provides worksheets to analyze total investment. Part II provides a system for evaluating investments based on purpose, target group, and delivery. In this Spending Calculator…
NASA Technical Reports Server (NTRS)
Stahr, J. D.; Auslander, D. M.; Spear, R. C.; Young, G. E.
1982-01-01
Life support systems for manned space missions are discussed. A scenario analysis method was proposed for the initial step of comparing possible partial or total recycle scenarios. The method is discussed in detail.
78 FR 63455 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
..., Building 23, Columbus, OH 43213-1152. Defense Manpower Data Center, 400 Gigling Road, Seaside CA 93955... web-based system providing a repository of military, Government civilian and contractor personnel and..., tracking, reporting, evaluating program effectiveness and conducting research. The Total Operational...
An assessment of the net value of CSP systems integrated with thermal energy storage
Mehos, M.; Jorgenson, J.; Denholm, P.; ...
2015-05-01
Within this study, we evaluate the operational and capacity value—or total system value—for multiple concentrating solar power (CSP) plant configurations under an assumed 33% renewable penetration scenario in California. We calculate the first-year bid price for two CSP plants, including a 2013 molten-salt tower integrated with a conventional Rankine cycle and a hypothetical 2020 molten-salt tower system integrated with an advanced supercritical carbon-dioxide power block. The overall benefit to the regional grid, defined in this study as the net value, is calculated by subtracting the first-year bid price from the total system value.
The development of fire evaluation system for detention and correctional occupancies
NASA Astrophysics Data System (ADS)
Nelson, H. E.; Shibe, A. J.
1984-12-01
A fire safety evaluation system for detention and correctional occupancies was developed. It can be used for determining if a facility has fire safety equivalent to that obtained by meeting the requirement of a given code. The system was calibrated for use with proposed chapters for detention and correctional occupancies of the Life Safety Code (1985). There are separate sets of requirements for each of four use conditions: one for zoned egress, one for zoned impeded egress, one for impeded egress, and one for contained. Within each set, there are two levels of evaluation: one for partially sprinklered and nonsprinklered buildings, and one for totally sprinklered buildings.
Welch, Brandon; Brinda, FNU
2017-01-01
Background Telemedicine is the use of technology to provide and support health care when distance separates the clinical service and the patient. Home-based telemedicine systems involve the use of such technology for medical support and care connecting the patient from the comfort of their homes with the clinician. In order for such a system to be used extensively, it is necessary to understand not only the issues faced by the patients in using them but also the clinician. Objectives The aim of this study was to conduct a heuristic evaluation of 4 telemedicine software platforms—Doxy.me, Polycom, Vidyo, and VSee—to assess possible problems and limitations that could affect the usability of the system from the clinician’s perspective. Methods It was found that 5 experts individually evaluated all four systems using Nielsen’s list of heuristics, classifying the issues based on a severity rating scale. Results A total of 46 unique problems were identified by the experts. The heuristics most frequently violated were visibility of system status and Error prevention amounting to 24% (11/46 issues) each. Esthetic and minimalist design was second contributing to 13% (6/46 issues) of the total errors. Conclusions Heuristic evaluation coupled with a severity rating scale was found to be an effective method for identifying problems with the systems. Prioritization of these problems based on the rating provides a good starting point for resolving the issues affecting these platforms. There is a need for better transparency and a more streamlined approach for how physicians use telemedicine systems. Visibility of the system status and speaking the users’ language are keys for achieving this. PMID:28438724
An analysis technique for testing log grades
Carl A. Newport; William G. O' Regan
1963-01-01
An analytical technique that may be used in evaluating log-grading systems is described. It also provides means of comparing two or more grading systems, or a proposed change with the system from which it was developed. The total volume and computed value of lumber from each sample log are the basic data used.
Cost Implications of an Interim Storage Facility in the Waste Management System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarrell, Joshua J.; Joseph, III, Robert Anthony; Howard, Rob L
2016-09-01
This report provides an evaluation of the cost implications of incorporating a consolidated interim storage facility (ISF) into the waste management system (WMS). Specifically, the impacts of the timing of opening an ISF relative to opening a repository were analyzed to understand the potential effects on total system costs.
Masdjedi, Kaneshka; Van Mieghem, Nicolas M; Diletti, Roberto; van Geuns, Robert-Jan; de Jaegere, Peter; Regar, Evelyn; Zijlstra, Felix; van Domburg, Ron T; Daemen, Joost
2017-04-15
To assess whether the RXi Navvus system compared to the use of standard Fractional Flow Reserve (FFR) wires reduces total contrast volume, radiation and overall study cost in a real world patient population referred for coronary angiography or percutaneous coronary intervention. FFR is the mainstay of functional hemodynamic assessment of coronary artery lesions. The RXi Navvus system (ACIST Medical Systems, Eden Prairie, MN) is a monorail microcatheter with FFR-measurement capability through optical pressure sensor technology. This is an investigator-initiated, prospective, single-center, observational cohort study. A total of 238 patients were enrolled, 97 patients with Navvus and 141 with conventional pressure-wire based FFR (PW-FFR). Final analyses were performed on the cohort in which only 1 device was used (82 Navvus procedures vs. 136 PW-FFR procedures). No significant differences were found in the total amount of contrast used (150±77 vs 147±79ml; p=0.81), radiation use (6200±4601 vs. 5076±4655 centiG∗cm 2 ; p=0.09) or costs (€1994,- vs. €1930,-; p=0.32) in the Navvus vs. PW-FFR groups respectively. No significant differences were found in the amount of contrast used, total procedural costs or radiation when the Navvus system was used as compared to conventional FFR wires. CONTRACT is an investigator-initiated, prospective, single-center, observational cohort study that evaluated whether the RXi Navvus system compared to the use of standard Fractional Flow Reserve (FFR) wires reduces total contrast volume, radiation and overall study cost in a real world patient population referred for coronary angiography or percutaneous coronary intervention. Use of the RXi Navvus system was associated with comparable procedural costs, amount of radiation and contrast used as compared to PW-FFR systems. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
2016-01-01
evaluation method that identifies the root causes of an undesired outcome and the Summary xix Root Cause of the JPALS Nunn-McCurdy Breach Under current... evaluation (RDT&E) unit (from 12 to 11) and an increase of one procurement unit for a new total of 27 procurement units. The revised procurement quantity...from the status of the overall portfolio of MDAPs and the status of other subportfolios. In assessing a portfolio, analysts may need to evaluate the
Schoen, Heidi R; Peyton, Brent M; Knighton, W Berk
2016-12-01
A novel analytical system was developed to rapidly and accurately quantify total volatile organic compound (VOC) production from microbial reactor systems using a platinum catalyst and a sensitive CO 2 detector. This system allows nearly instantaneous determination of total VOC production by utilizing a platinum catalyst to completely and quantitatively oxidize headspace VOCs to CO 2 in coordination with a CO 2 detector. Measurement of respiratory CO 2 by bypassing the catalyst allowed the total VOC content to be determined from the difference in the two signals. To the best of our knowledge, this is the first instance of a platinum catalyst and CO 2 detector being used to quantify the total VOCs produced by a complex bioreactor system. Continuous recording of these CO 2 data provided a record of respiration and total VOC production throughout the experiments. Proton transfer reaction-mass spectrometry (PTR-MS) was used to identify and quantify major VOCs. The sum of the individual compounds measured by PTR-MS can be compared to the total VOCs quantified by the platinum catalyst to identify potential differences in detection, identification and calibration. PTR-MS measurements accounted on average for 94 % of the total VOC carbon detected by the platinum catalyst and CO 2 detector. In a model system, a VOC producing endophytic fungus Nodulisporium isolate TI-13 was grown in a solid state reactor utilizing the agricultural byproduct beet pulp as a substrate. Temporal changes in production of major volatile compounds (ethanol, methanol, acetaldehyde, terpenes, and terpenoids) were quantified by PTR-MS and compared to the total VOC measurements taken with the platinum catalyst and CO 2 detector. This analytical system provided fast, consistent data for evaluating VOC production in the nonhomogeneous solid state reactor system.
Reliability and validity of the Microsoft Kinect for evaluating static foot posture
2013-01-01
Background The evaluation of foot posture in a clinical setting is useful to screen for potential injury, however disagreement remains as to which method has the greatest clinical utility. An inexpensive and widely available imaging system, the Microsoft Kinect™, may possess the characteristics to objectively evaluate static foot posture in a clinical setting with high accuracy. The aim of this study was to assess the intra-rater reliability and validity of this system for assessing static foot posture. Methods Three measures were used to assess static foot posture; traditional visual observation using the Foot Posture Index (FPI), a 3D motion analysis (3DMA) system and software designed to collect and analyse image and depth data from the Kinect. Spearman’s rho was used to assess intra-rater reliability and concurrent validity of the Kinect to evaluate foot posture, and a linear regression was used to examine the ability of the Kinect to predict total visual FPI score. Results The Kinect demonstrated moderate to good intra-rater reliability for four FPI items of foot posture (ρ = 0.62 to 0.78) and moderate to good correlations with the 3DMA system for four items of foot posture (ρ = 0.51 to 0.85). In contrast, intra-rater reliability of visual FPI items was poor to moderate (ρ = 0.17 to 0.63), and correlations with the Kinect and 3DMA systems were poor (absolute ρ = 0.01 to 0.44). Kinect FPI items with moderate to good reliability predicted 61% of the variance in total visual FPI score. Conclusions The majority of the foot posture items derived using the Kinect were more reliable than the traditional visual assessment of FPI, and were valid when compared to a 3DMA system. Individual foot posture items recorded using the Kinect were also shown to predict a moderate degree of variance in the total visual FPI score. Combined, these results support the future potential of the Kinect to accurately evaluate static foot posture in a clinical setting. PMID:23566934
Evaluation of Military Trauma System Practices Related to Complications After Injury
2012-01-01
and ventilator- associated pneumonia (VAP).3Y5 This current analysis illustrates three key examples of trauma system PI initiatives related to...the Abbreviated Injury Scale (AIS) body re- gion of 7 (upper extremity) or 8 (lower extremity). Compartment syndrome patients were identified in the...queried met the inclusion criteria for the VAP evaluation study. Of the total study popu- lation, 1.7% of patients (n = 107) acquired VAP, whereas
Ultrasonic Doppler measurement of renal artery blood flow
NASA Technical Reports Server (NTRS)
Freund, W. R.; Meindl, J. D.
1975-01-01
An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.
Augusto, Gustavo A; Sousa, André G P; Perazo, Marcela N A; Correa-Giannella, Maria L C; Nery, Marcia; Melo, Karla F S de
2009-06-01
Continuous glucose monitoring system is a valuable instrument to measure glycemic control, which uses a retrospective calibration based upon 3 to 4 capillary glucose meter values inserted by the patient each day. We evaluated the interference of calibration during the dawn period in the system accuracy. The monitoring data were retrospectively divided into two groups: with (Group A) or without (Group B) the dawn period calibration (between 1:00 and 5:00 AM). Accuracy of the method was expressed by relative absolute difference. Thirty-four continuous glucose monitoring data were evaluated comprising a total of 112 nights. A total of 289 paired readings were analyzed - 195 in Group A and 94 in Group B. We did not find a difference in relative absolute difference (RAD%) in any analyzed period of day by adding dawn calibration. These data suggest that dawn calibration does not alter accuracy of method.
Power processing methodology. [computerized design of spacecraft electric power systems
NASA Technical Reports Server (NTRS)
Fegley, K. A.; Hansen, I. G.; Hayden, J. H.
1974-01-01
Discussion of the interim results of a program to investigate the feasibility of formulating a methodology for the modeling and analysis of aerospace electrical power processing systems. The object of the total program is to develop a flexible engineering tool which will allow the power processor designer to effectively and rapidly assess and analyze the tradeoffs available by providing, in one comprehensive program, a mathematical model, an analysis of expected performance, simulation, and a comparative evaluation with alternative designs. This requires an understanding of electrical power source characteristics and the effects of load control, protection, and total system interaction.
MUSE--Model for University Strategic Evaluation. AIR 2002 Forum Paper.
ERIC Educational Resources Information Center
Kutina, Kenneth L.; Zullig, Craig M.; Starkman, Glenn D.; Tanski, Laura E.
A model for simulating college and university operations, finances, program investments, and market response in terms of applicants, acceptances, and retention has been developed and implemented using the system dynamics approach. The Model for University Strategic Evaluation (MUSE) is a simulation of the total operations of the university,…
Police Selection and Career Assessment.
ERIC Educational Resources Information Center
Dunnette, Marvin D.; Motowidlo, Stephan J.
Research was conducted to develop the Police Career Index (PCI) and the regional assessment center exercises to provide a total personnel evaluation system to help police departments screen applicants, evaluate on-the-job performance of officers eligible for promotion, and gauge a person's suitability for police work. The PCI is based on actual…
Elevating the Importance of Teaching. National Project III. Final Report.
ERIC Educational Resources Information Center
Owens, Richard E.
An in-depth study was conducted of instructional improvement activities at Kansas State University, including a student evaluation instrument of teacher performance, called Instructional Development and Effectiveness Assessment (IDEA). Faculty reactions to the total evaluation system, the use of results for multiple purposes, and the current…
ERIC Educational Resources Information Center
Kraipetch, Chanita; Kanjanawasee, Sirichai; Prachyapruit, Apipa
2013-01-01
The present research was aimed to: 1) develop the components and indicators of organizational effectiveness for public higher education institutions under the Ministry of Tourism and Sports, Thailand, and 2) develop organizational effectiveness evaluation system for these institutions. The sample included total 41 participants comprising…
ERIC Educational Resources Information Center
Pressman, Israel; Rosenbloom, Bruce
1984-01-01
Describes and evaluates costs of hardware, software, training, and maintenance for computer assisted instruction (CAI) as they relate to total system cost. An example of an educational system provides an illustration of CAI cost analysis. Future developments, cost effectiveness, affordability, and applications in public and private environments…
Effect of process parameters on greenhouse gas generation by wastewater treatment plants.
Yerushalmi, L; Shahabadi, M Bani; Haghighat, F
2011-05-01
The effect of key process parameters on greenhouse gas (GHG) emission by wastewater treatment plants was evaluated, and the governing parameters that exhibited major effects on the overall on- and off-site GHG emissions were identified. This evaluation used aerobic, anaerobic, and hybrid anaerobic/aerobic treatment systems with food processing industry wastewater. The operating temperature of anaerobic sludge digester was identified to have the highest effect on GHG generation in the aerobic treatment system. The total GHG emissions of 2694 kg CO2e/d were increased by 72.5% with the increase of anaerobic sludge digester temperature from 20 to 40 degrees C. The operating temperature of the anaerobic reactor was the dominant controlling parameter in the anaerobic and hybrid treatment systems. Raising the anaerobic reactor's temperature from 25 to 40 degrees C increased the total GHG emissions from 5822 and 6617 kg CO2e/d by 105.6 and 96.5% in the anaerobic and hybrid treatment systems, respectively.
Beck-Krala, Ewa; Klimkiewicz, Katarzyna
2016-12-01
Occupational safety and health (OSH) plays a significant role in today's organizations, because it helps in attracting and retaining employees as well as molding their attitudes and behaviors at work. This is why the issue of OSH is stressed in a comprehensive approach to employee rewards: the total reward concept. This article explains how OSH may be included in a complex evaluation process of the compensation system. Although the literature on the effectiveness of employee compensation refers mainly to financial and non-financial components, there is a need for inclusion of working conditions in such analyses. An evaluation of the compensation system that incorporates OSH can drive many benefits for both the organization and employees. Obtaining such benefits, however, requires systematic evaluation of the reward system, including OSH. Incorporation of OSH issue within the comprehensive analysis of compensation systems promotes responsible behavior of all stakeholders.
Nondestructive structural evaluation of wood floor systems with a vibration technique.
Xiping Wang; Robert J. Ross; Lawrence Andrew Soltis
2002-01-01
The objective of this study was to determine if transverse vibration methods could be used to effectively assess the structural integrity of wood floors as component systems. A total of 10 wood floor systems, including 3 laboratory-built floor sections and 7 in-place floors in historic buildings, were tested. A forced vibration method was applied to the floor systems...
Ren, Feiyue; Reilly, Kim; Gaffney, Michael; Kerry, Joseph P; Hossain, Mohammad; Rai, Dilip K
2017-07-01
Onions contain a number of bioactive compounds, in particular polyphenols. They are rich sources of such compounds in the human diet and offer significant health benefits to the consumer. Demand for organic crops is steadily increasing partly based on the expected health benefits of organic food consumption. The current study examines the influence of organic and conventional crop management practices on bioactive polyphenolic content of onion. We examined the effect of conventional, organic, and mixed cultivation practices on the content of total phenolics, total flavonoids and antioxidant activity in two varieties of onion grown over 4 years in a split-plot factorial systems comparison trial. Levels of total phenolics and total flavonoids showed a significant year-on-year variation and were significantly different between organic and conventional production systems. The levels of total phenolics, total flavonoids and antioxidant activity in general were significantly higher (P < 0.05) under fully organic compared to fully conventional management. Organic cultivation practices resulted in significantly higher levels of potential bioactive compounds in onion. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Systems design and comparative analysis of large antenna concepts
NASA Technical Reports Server (NTRS)
Garrett, L. B.; Ferebee, M. J., Jr.
1983-01-01
Conceptual designs are evaluated and comparative analyses conducted for several large antenna spacecraft for Land Mobile Satellite System (LMSS) communications missions. Structural configurations include trusses, hoop and column and radial rib. The study was conducted using the Interactive Design and Evaluation of Advanced Spacecraft (IDEAS) system. The current capabilities, development status, and near-term plans for the IDEAS system are reviewed. Overall capabilities are highlighted. IDEAS is an integrated system of computer-aided design and analysis software used to rapidly evaluate system concepts and technology needs for future advanced spacecraft such as large antennas, platforms, and space stations. The system was developed at Langley to meet a need for rapid, cost-effective, labor-saving approaches to the design and analysis of numerous missions and total spacecraft system options under consideration. IDEAS consists of about 40 technical modules efficient executive, data-base and file management software, and interactive graphics display capabilities.
Tri-service Disability Evaluation Systems Database Analysis and Research Annual Report 2012
2012-10-02
other chest symptoms 86 2.6 Internal derangement of knee 392 2.0 Other cellulitis and abscess 75 2.3 Total DES Cases Hospitalized 19,359 100 Total...Febrile convulsions (simple), unspecified 59 4.6 Epilepsy 6 3.8 Adjustment reaction 34 2.6 Malignant neoplasm of brain 5 3.1 Other cellulitis and
The dimensions of responsiveness of a health system: a Taiwanese perspective.
Hsu, Chih-Cheng; Chen, Likwang; Hu, Yu-Whuei; Yip, Winnie; Shu, Chen-Chun
2006-03-17
Responsiveness is an indicator used to measure how well a health system performs relative to non-health aspects. This study assessed whether seven dimensions proposed by the World Health Organization (WHO) to measure responsiveness (dignity, autonomy, confidentiality, prompt attention, social support, basic amenities, and choices of providers) are applicable in evaluating the health system of Taiwan. A key informant survey and focus group research were used in this study. The translated WHO proposed questionnaire was sent to 205 nominated key informants by mail, and 132 (64.4%) were returned. We used principal component analysis to extract factors. Linear regression analysis was used to assess the relationship between the total score and the extracted factors. A qualitative content analysis was also carried out in focus group research. Principal component analysis produced five factors (respect, access, confidentiality, basic amenities, and social support) that explained 63.5% of the total variances. These five factors demonstrated acceptable internal consistency and four of them (except social support) were significantly correlated with the total responsiveness score. The focus group interviews revealed health providers' communication ability and medical ethics were also highly appraised by Taiwanese. When the performance of a health system is to be evaluated, elements of responsiveness proposed by WHO may have to be tailored to fit different cultural backgrounds. Four key features illustrate the uniqueness of Taiwanese perspectives: the idea of autonomy may not be conceptualized, prompt attention and choice of providers are on the same track, social support during care is trivially correlated to the total responsiveness score, and accountability of health providers is deemed essential to a health system.
Wang, Dongbin; Shafer, Martin M; Schauer, James J; Sioutas, Constantinos
2015-04-01
This study presents a novel system for online, field measurement of copper (Cu) in ambient coarse (2.5-10 μm) particulate matter (PM). This new system utilizes two virtual impactors combined with a modified liquid impinger (BioSampler) to collect coarse PM directly as concentrated slurry samples. The total and water-soluble Cu concentrations are subsequently measured by a copper Ion Selective Electrode (ISE). Laboratory evaluation results indicated excellent collection efficiency (over 85%) for particles in the coarse PM size ranges. In the field evaluations, very good agreements for both total and water-soluble Cu concentrations were obtained between online ISE-based monitor measurements and those analyzed by means of inductively coupled plasma mass spectrometry (ICP-MS). Moreover, the field tests indicated that the Cu monitor could achieve near-continuous operation for at least 6 consecutive days (a time resolution of 2-4 h) without obvious shortcomings. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kim, Kyung Taek; Kang, Min Soo; Lim, Young Hoon; Park, Jin Woo
2014-01-01
Purpose To evaluate the clinical and radiological results of total knee arthroplasty (TKA) using the anterior-posterior glide (APG) low contact stress (LCS) mobile-bearing system. Materials and Methods We evaluated 130 knees in 117 patients who had undergone TKA with APG LCS mobile-bearing system between September 2005 and July 2007 and could be followed over 5 years. The mean follow-up period was 68 months. The clinical and radiological results were evaluated using the American Knee Society Scoring System, Oxford knee score and the American Knee Society Roentgenographic Evaluation and Scoring System. And we analyzed short-term postoperative complications. Results The average range of motion of the knee joint was 107.9° (range, 70° to 135°) preoperatively and 125.2° (range, 90° to 135°) at the last follow-up. The average knee and functional scores were improved from 39.1 and 42.0 to 71.2 and 75.6, respectively, between the preoperative and last follow-up evaluation. The Oxford knee score was decreased from 42.9 preoperatively to 23.1 at the last follow-up. The femoro-tibial angle (anatomical axis) changed from 10.1° varus preoperatively to 3.3° valgus at the last follow-up. Radiolucency was observed in 14% of all cases. There were 1 case of traumatic dislocation of the polyethylene liner, 1 case of aseptic loosening and 6 cases of posterior instability because of posterior cruciate ligament (PCL) insufficiency. Conclusions TKA with APG LCS mobile-bearing system demonstrated relatively good short-term clinical and radiological results. However, further considerations for posterior instability associated with PCL insufficiency are needed. PMID:25229046
Photovoltaic-system evaluation at the Northeast Residential Experiment Station
NASA Astrophysics Data System (ADS)
Russell, M. C.
1983-01-01
Five residential photovoltaic systems were tested and the systems' performance and cost was evaluated. The five systems each consist of an unoccupied structure employing a roof mounted photovoltaic array and a utility connected power inverter capable of sending excess PV generated energy to the local utility system. The photovoltaic systems are designed to meet at least 50% of the total annual electrical demand of residences in the cold climate regions of the country. The following specific issues were investigated: photovoltaic array and inverter system power rating and performance characterization, system energy production, reliability and system cost/worth. Summary load data from five houses in the vicinity of the Northeast Residential Experiment Station, and meteorological data from the station's weather station are also presented.
The effect of upper gastrointestinal system endoscopy process on serum oxidative stress levels.
Turan, Mehmet Nuri; Aslan, Mehmet; Bolukbas, Filiz Fusun; Bolukbas, Cengiz; Selek, Sahbettin; Sabuncu, Tevfik
2016-12-01
Some authors have investigated the effects of oxidative stress in some process such as undergoing laparoscopic. However, the effect of upper gastrointestinal system endoscopy process on oxidative stress is unclear. We evaluated the short-term effect of upper gastrointestinal system endoscopy process on oxidative stress. Thirty patients who underwent endoscopy process and 20 healthy controls were enrolled in the prospective study. Serum total antioxidant capacity and total oxidant status measurements were measured before and after endoscopy process. The ratio percentage of total oxidant status to total antioxidant capacity was regarded as oxidative stress index. Before endoscopy process, serum total antioxidant capacity levels were higher, while serum total oxidant status levels and oxidative stress index values were lower in patients than controls, but this difference was not statistically significant (all, p > 0.05). After endoscopy process, serum total antioxidant capacity and total oxidant status levels were significantly higher in patients than before endoscopy process (both, p < 0.05). However, oxidative stress index values were slight higher in patients but this difference was not statistically significant (p > 0.05). We observed that serum TAC and TOS levels were increased in patients who underwent endoscopy process after endoscopy process. However, short-time upper gastrointestinal system endoscopy process did not cause an important change in the oxidative stress index. Further studies enrolling a larger number of patients are required to clarify the results obtained here.
EVALUATION OF MERCURY SPECIATION AT POWER PLANTS USING SCR AND SNCR NOX CONTROL TECHNOLOGIES
The paper describes the impact that selective catalytic reduction (SCR), selective noncatalytic reduction (SNCR), and flue gas-conditioning systems have on total mercury emissions and on the speciation of mercury. If SCR and/or SNCR systems enhance mercury conversion/capture, the...
EVALUATION OF MERCURY SPECIATION AT POWER PLANTS USING SCR AND SNCR CONTROL TECHNOLOGIES
The paper describes the impact that selective catalytic reduction (SCR), selective noncatalytic reduction (SNCR), and flue gas-conditioning systems have on total mercury emissions and on the speciation of mercury. If SCR and/or SNCR systems enhance mercury conversion/capture, the...
The Synchronous Scanning Luminoscope (Luminoscope) developed by the Oak Ridge National Laboratory in collaboration with Environmental Systems Corporation (ESC) was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program i...
Employee Engagement Is Vital for the Successful Selection of a Total Laboratory Automation System.
Yu, Hoi-Ying E; Wilkerson, Myra L
2017-11-08
To concretely outline a process for selecting a total laboratory automation system that connects clinical chemistry, hematology, and coagulation analyzers and to serve as a reference for other laboratories. In Phase I, a committee including the laboratory's directors and technologists conducted a review of 5 systems based on formal request for information process, site visits, and vendor presentations. We developed evaluation criteria and selected the 2 highest performing systems. In Phase II, we executed a detailed comparison of the 2 vendors based on cost, instrument layout, workflow design, and future potential. In addition to selecting a laboratory automation system, we used the process to ensure employee engagement in preparation for implementation. Selecting a total laboratory automation system is a complicated process. This paper provides practical guide in how a thorough selection process can be done with participation of key stakeholders. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
1987-11-01
Salix nigra). and cocklebur (Xanthium strumarium ) occurred in all 10 dike systems. False indigo (Amorpha fruticosa). day 6 flower (Commelina diffusa...Xanthium strumarium + + + + + + + + + + Number of species recorded by dike system 11 33 56 58 33 50 50 39 52 18 Percent of total number of species
Nduwimana, André; Yang, Xiang-Long; Wang, Li-Ren
2007-01-01
Wastewater stabilization ponds generate low cost by-products that are useful for agriculture. The utilization of these by-products for soil amendment and as a source of nutrients for plants requires a high level of sanitation and stabilization of the organic matter, to maintain acceptable levels of soil, water and air quality. In this study, two aquaculture wastewater treatment systems; recirculating system and a floating plant bed system were designed to improve the quality of irrigation water in local communities with low income. In both systems the grass species Lolium perenne Lam was used as a plant biofilter while vegetable specie Amaranthus viridis was used to evaluate the performance of the system and the suitability of the phyto-treated water for irrigation. It was found that the harmful material removal rate for recirculating system was 88.9% for TAN (total ammonia nitrogen), 90% for NO2(-)-N, 64.8% for NO3(-)-N while for floating plant bed system 82.7% for TAN, 82% for NO2(-)-N and 60.5% for NO3(-)-N. Comparative analysis of the efficiency of waste element removal between the two systems revealed that both systems performed well, however, plant growth was not robust for floating plant bed system while recirculating system is energy consuming. Although both systems did not attain sufficient levels of TN (total nitrogen) and TP (total phosphorus) load reduction, the treatment with L. perenne remarkably improved the irrigation water quality. A. viridis plants irrigated with the phyto-treated discharge water had lesser concentrations of heavy metals in their tissues compared to those irrigated with untreated discharge. The control plants irrigated with untreated discharge were also found to be highly lignified with few stems and small leaves.
Efficiency of an emissions payment system for nitrogen in sewage treatment plants - a case study.
Malmaeus, J Mikael; Ek, Mats; Åmand, Linda; Roth, Susanna; Baresel, Christian; Olshammar, Mikael
2015-05-01
An emissions payment system for nitrogen in Swedish sewage treatment plants (STPs) was evaluated using a semi-empirical approach. The system was based on a tariff levied on each unit of nitrogen emitted by STPs, and profitable measures to reduce nitrogen emissions were identified for twenty municipal STPs. This was done through direct involvement with the plant personnel and the results were scaled up to cover all treatment plants larger than 2000 person equivalents in the Swedish tributary areas of the Kattegat and the Baltic Proper. The sum of costs and nitrogen reductions were compared with an assumed command-and-control regulation requiring all STPs to obtain 80% total nitrogen reduction in their effluents. Costs for the latter case were estimated using a database containing standard estimates for reduction costs by six specified measures. For both cases a total reduction target of 3000 tonnes of nitrogen was set. We did not find that the emissions payment system was more efficient in terms of total reduction costs, although some practical and administrative advantages could be identified. Our results emphasize the need to evaluate the performance of policy instruments on a case-by-case basis since the theoretical efficiency is not always reflected in practice. Copyright © 2015 Elsevier Ltd. All rights reserved.
Tampekis, Stergios; Samara, Fani; Sakellariou, Stavros; Sfougaris, Athanassios; Christopoulou, Olga
2018-02-12
The sustainable forest management can be achieved only through environmentally sound and economically efficient and feasible forest road networks and transportation systems that can potentially improve the multi-functional use of forest resources. However, road network planning and construction suggest long-term finance that require a capital investment (cash outflow), which would be equal to the value of the total revenue flow (cash inflow) over the whole lifecycle project. This paper emphasizes in an eco-efficient and economical optimum evaluation method for the forest road networks in the mountainous forest of Metsovo, Greece. More specifically, with the use of this technique, we evaluated the forest roads' (a) total construction costs, (b) annual maintenance cost, and (c) log skidding cost. In addition, we estimated the total economic value of forest goods and services that are lost from the forest roads' construction. Finally, we assessed the optimum eco-efficient and economical forest roads densities based on linear equations that stem from the internal rate of return method (IRR) and have been presented graphically. Data analysis and its presentation are achieved with the contribution of geographic information systems (GIS). The technique which is described in this study can be for the decision makers an attractive and useful implement in order to select the most eco-friendly and economical optimum solution to plan forest road network or to evaluate the existing forest transportation systems. Hence, with the use of this method, we can combine not only the multi-objective utilization of natural resources but also the environmental protection of forest ecosystems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, T.
1993-07-01
The report summarizes the findings of an evaluation of the Basic Extractive Sludge Treatment (B.E.S.T.) solvent extraction technology developed by Resources Conservation Company (RCC). During the demonstration test, the B.E.S.T. system was used to treat composited sediments from two areas of the Grand Calumet River. Contaminant concentration reductions of 96 percent for total polynuclear aromatic hydrocarbons (PAHs) and greater than 99 percent for total polychlorinated biphenyls (PCBs) were achieved for Sediment A. Contaminant concentration reductions of greater than 99 percent for total PAHs and greater than 99 percent for total PCBs were achieved for Sediment B. Removal efficiencies in excessmore » of 98 percent were realized for both sediments for oil and grease (O G).« less
Dosimetric evaluation of total marrow irradiation using 2 different planning systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nalichowski, Adrian, E-mail: nalichoa@karmanos.org; Eagle, Don G.; Burmeister, Jay
This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using themore » Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.« less
NASA Technical Reports Server (NTRS)
Schramm, Harry F.; Sullivan, Kenneth W.
1991-01-01
An evaluation of the NASA's Marshall Space Flight Center (MSFC) strategy to implement Total Quality Management (TQM) in the Advanced Solid Rocket Motor (ASRM) Project is presented. The evaluation of the implementation strategy reflected the Civil Service personnel perspective at the project level. The external and internal environments at MSFC were analyzed for their effects on the ASRM TQM strategy. Organizational forms, cultures, management systems, problem solving techniques, and training were assessed for their influence on the implementation strategy. The influence of ASRM's effort was assessed relative to its impact on mature projects as well as future projects at MSFC.
Economic burden of psoriatic patients in Japan: Analysis from a single outpatient clinic.
Takahashi, Hidetoshi; Satoh, Katsuhiko; Takagi, Akiyoshi; Iizuka, Hajime
2017-09-01
Topical and systemic agents have dramatically improved the treatment efficacy of psoriasis. Few reports, however, exist describing the economic burden in Japanese psoriatic patients. The aim of the study was to evaluate the total costs as well as cost versus efficacy of topical and systemic treatments of psoriatic patients under the Japanese health insurance system. The retrospective study was performed from the database of our clinic, which is located in Hokkaido Prefecture. Cost and effectiveness of psoriatic patients were evaluated during the 12-month period from April 2015 to March 2016. Data were collected and calculated for the total cost per year, treatment efficacy and cost versus efficacy. The mean total cost of topical corticosteroid treatment was ¥18 184/year and was lowest among the treatments. The systemic treatment with biologics was most expensive and the costs were over ¥400 000/year. Among the topical treatments, calcipotriol/betamethasone dipropionate was most expensive (¥34 693/year). However, cost versus efficacy was not significantly different from that of topical corticosteroid treatments. The cost of secukinumab was highest among all the treatments (¥631 600/year). However, treatment day per cost was lowest of all the psoriasis treatments. Biologics showed the highest cost than topical or systemic treatments. However, they showed most marked efficacy in terms of improving the psoriatic skin lesions. © 2017 Japanese Dermatological Association.
Application of structured analysis to a telerobotic system
NASA Technical Reports Server (NTRS)
Dashman, Eric; Mclin, David; Harrison, F. W.; Soloway, Donald; Young, Steven
1990-01-01
The analysis and evaluation of a multiple arm telerobotic research and demonstration system developed by the NASA Intelligent Systems Research Laboratory (ISRL) is described. Structured analysis techniques were used to develop a detailed requirements model of an existing telerobotic testbed. Performance models generated during this process were used to further evaluate the total system. A commercial CASE tool called Teamwork was used to carry out the structured analysis and development of the functional requirements model. A structured analysis and design process using the ISRL telerobotic system as a model is described. Evaluation of this system focused on the identification of bottlenecks in this implementation. The results demonstrate that the use of structured methods and analysis tools can give useful performance information early in a design cycle. This information can be used to ensure that the proposed system meets its design requirements before it is built.
Tutorial: Radiation Effects in Electronic Systems
NASA Technical Reports Server (NTRS)
Pellish, Jonathan A.
2017-01-01
This tutorial presentation will give an overview of radiation effects in electrical, electronic, and electromechanical (EEE) components as it applies to civilian space systems of varying size and complexity. The natural space environment presents many unique threats to electronic systems regardless of where the systems operate from low-Earth orbit to interplanetary space. The presentation will cover several topics, including: an overview and introduction to the applicable space radiation environments common to a broad range of mission designs; definitions and impacts of effects due to impinging particles in the space environment e.g., total ionizing dose (TID), total non-ionizing dose (TNID), and single-event effects (SEE); and, testing for and evaluation of TID, TNID, and SEE in EEE components.
Ramakrishna Mission initiative impact study: final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chaurey, A.
2000-07-06
This report has been prepared by the Tata Energy Research Institute (TERI) for the National Renewable Energy Laboratory. It presents the results of the evaluation and impact assessment of solar photovoltaic lighting systems in the region of Sunderbans, West Bengal, that were deployed by a reputable non-governmental organization (Ramakrishna Mission) under the auspices of the INDO-US collaborative project. The objectives of the study were to evaluate the solar photovoltaic systems for their impact on the individual households as well as on the community, to assess the effectiveness of the implementation and financial mechanisms, and to draw a long-term strategy formore » NREL's activities in Sunderbans based on case studies of similar interventions. Under the project, provision was made to supply 300 domestic lighting systems (DLS) based on 53-Wp module capacity to individual households and a few other systems such as for lighting, medical refrigeration, and pumping water to community centers. For this study, 152 households were surveyed, of which 29 had also been a part of earlier pre- and post-installation surveys, 47 had been a part of the earlier post-installation survey, and 76 were households that were surveyed for the first time. A set of 46, out of the total 152 households, was selected for evaluating the systems for their technical performance with respect to module output, condition of the battery, and daily energy consumption. Of the total 300 modules, 2 had been stolen, 9 out of the total 300 batteries needed to be replaced, and 10 out of the 300 charge controllers were non-functional. The statistics for the surveyed households indicate 32 luminaire-related faults (blackening or flickering of compact fluorescent lights) and 11 other faults related to fuses, switches, etc.« less
POWER PLANT EVALUATION OF THE EFFECT OF SCR TECHNOLOGY ON MERCURY
The paper presents results of research on the impact that selective catalytic reduction (SCR) systems have on speciation and total emissions of mercury. Although SCR systems are designed to reduce nitrogen oxides (NOx), they may oxidize elemental mercury (Hg0) to Hg2+, which is m...
The PetroFLAGTm System developed by Dexsilo Corporation (Dexsil) was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose o...
Evaluation of the performance of the Tyson Foods wastewater treatment plant for nitrogen removal.
Ubay-Cokgor, E; Randall, C W; Orhon, D
2005-01-01
In this paper, the performance of the Tyson Foods wastewater treatment plant with an average flow rate of 6500 m3/d was evaluated before and after upgrading of the treatment system for nitrogen removal. This study was also covered with an additional recommendation of BIOWIN BNR program simulation after the modification period to achieve an additional nutrient removal. The results clearly show that the upgrading was very successful for improved nitrogen removal, with a 57% decrease on the total nitrogen discharge. There also were slight reductions in the discharged loads of biological oxygen demand, total suspended solids, ammonium and total phosphorus with denitrification, even though the effluent flow was higher during operation of the nitrogen removal configuration.
Flight test summary of modified fuel systems
NASA Technical Reports Server (NTRS)
Barrett, B. G.
1976-01-01
Two different aircraft designs, each with two modified fuel control systems, were evaluated. Each aircraft was evaluated in a given series of defined ground and flight conditions while quantitative and qualitative observations were made. During this program, some ten flights were completed, and a total of about 13 hours of engine run time was accumulated by the two airplanes. The results of these evaluations with emphasis on the operational and safety aspects were analyzed. Ground tests of the engine alone were not able to predict acceptable limiting lean mixture settings for the flight envelopes of the Cessna Models 150 and T337.
Safety evaluation -- Spent water treatment system components inventory release
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dodd, E.N. Jr.
1995-01-24
Over the past few years various impediments to shipment of generated spent basin water treatment system components have resulted in the accumulation of quantities of these waste items at 100K. Specifically, there are (as of 01/01/95) 13 grout/culvert packaged cartridge filters (CF), four unpackaged cartridge filters, 60 spent ion exchange columns (IXC) and seven ion exchange modules (IXM) at 100K awaiting shipment for final waste disposal. As a result of the accumulation of this waste, the question has arisen regarding the consequences of potential releases of the inventory of radionuclides in these waste items relative to the K Area safetymore » envelope. The purpose of this paper is to address this question. The initial step evaluating the consequences of potential release of material from the spent water treatment system components was to determine the individual and total radionuclide inventories of concern. Generally the radioisotopes of concern to the dose consequences were Sr/Y-90, Cs-137, and the transuranic (TRU) isotopes. The loading of these radioisotopes needed to be determined for each of the components of the total number of accumulated IXCs, IXMs and CFs. This evaluation examines four potential releases of material from the spent water treatment system components. These releases are: the release of material from all 39 IXCs stored in 183-KW; the release of material from the IXCs, IXMs and CFs at 105-KE and 105-KW; the release of material from the 13 CFs stored behind 105-KE; and the non-mechanistic release of the total stored waste inventory.« less
Hartzell, Sharon E; Unger, Michael A; Vadas, George G; Yonkos, Lance T
2018-03-01
Although the complexity of contaminant mixtures in sediments can confound the identification of causative agents of adverse biological response, understanding the contaminant(s) of primary concern at impacted sites is critical to sound environmental management and remediation. In the present study, a stock mixture of 18 polycyclic aromatic hydrocarbon (PAH) compounds was prepared to reflect the variety and relative proportions of PAHs measured in surface sediment samples collected from discrete areas of a historically contaminated industrial estuary. This site-specific PAH stock mixture was spiked into nontoxic in-system and out-of-system field-collected reference sediments in dilution series spanning the range of previously measured total PAH concentrations from the region. Spiked sediments were evaluated in 10-d Leptocheirus plumulosus tests to determine whether toxicity in laboratory-created PAH concentrations was similar to the toxicity found in field-collected samples with equivalent PAH concentrations. The results show that toxicity of contaminated sediments was not explained by PAH exposure, while indicating that toxicity in spiked in-system (fine grain, high total organic carbon [TOC]) and out-of-system (course grain, low TOC) sediments was better explained by porewater PAH concentrations, measured using an antibody-based biosensor that quantified 3- to 5-ring PAHs, than total sediment PAH concentrations. The study demonstrates the application of site-specific spiking experiments to evaluate sediment toxicity at sites with complex mixtures of multiple contaminant classes and the utility of the PAH biosensor for rapid sediment-independent porewater PAH analysis. Environ Toxicol Chem 2018;37:893-902. © 2017 SETAC. © 2017 SETAC.
Disability Evaluation Systems Analysis and Research Annual Report 2016
2016-08-10
0.6 Hearing loss 17 3.4 0.5 Other and unspecified disorders of bone and cartilage 43 3.1 0.4 Asthma 16 3.2 0.5 Cannabis abuse 42 3.0 0.4 Contact ... dermatitis and other eczema 12 2.4 0.3 Total Applicants with Medical Conditions 1,398 13.6 Total Applicants with Medical Conditions 497
USDA-ARS?s Scientific Manuscript database
A feeding trial was conducted in a closed system with Nile tilapia (Oreochromis niloticus) juveniles (mean weight, 2.84 g) to examine the effects of total replacement of fish meal (FM), with and without supplementation of DL-methionine (Met) and L-lysine (Lys), by plant protein sources. Fish were f...
Cuevas, Francisco Julián; Pradas, Inmaculada; Ruiz-Moreno, María José; Arroyo, Francisco Teodoro; Perez-Romero, Luis Felipe; Montenegro, José Carlos; Moreno-Rojas, José Manuel
2015-01-01
In this study, thirteen Japanese plum cultivars (Prunus salicina Lindl.) grown under conventional and organic conditions were compared to evaluate the influence of the culture system on bioactive compounds. Their organic acids content (malic, citric, tartaric, succinic, shikimic, ascorbic and fumaric acid), total polyphenols, total anthocyanins, total carotenoids and antioxidant capacity (FRAP, ABTS) were evaluated. The study was performed during two consecutive seasons (2012 and 2013) in two experimental orchards located at the IFAPA centre Las Torres-Tomejil (Seville, SW Spain). The culture system affected all the studied parameters except for total carotenoid content. The organic plums had significantly higher polyphenol and anthocyanin concentrations and a greater antioxidant capacity. Additionally, significant differences between cultivars were also found. 'Showtime' and 'Friar' were the cultivars with the highest polyphenol concentration and antioxidant capacity. 'Black Amber' had the highest anthocyanin content and 'Larry Ann' and 'Songold' the highest carotenoid content. 'Sapphire' and 'Black amber' were the cultivars with the highest concentration of ascorbic acid. Our results showed a strong year effect. In conclusion, organic management had an impact on the production of phytochemical compounds in plums.
Cuevas, Francisco Julián; Pradas, Inmaculada; Ruiz‐Moreno, María José; Arroyo, Francisco Teodoro; Perez-Romero, Luis Felipe; Montenegro, José Carlos; Moreno‐Rojas, José Manuel
2015-01-01
In this study, thirteen Japanese plum cultivars (Prunus salicina Lindl.) grown under conventional and organic conditions were compared to evaluate the influence of the culture system on bioactive compounds. Their organic acids content (malic, citric, tartaric, succinic, shikimic, ascorbic and fumaric acid), total polyphenols, total anthocyanins, total carotenoids and antioxidant capacity (FRAP, ABTS) were evaluated. The study was performed during two consecutive seasons (2012 and 2013) in two experimental orchards located at the IFAPA centre Las Torres-Tomejil (Seville, SW Spain). The culture system affected all the studied parameters except for total carotenoid content. The organic plums had significantly higher polyphenol and anthocyanin concentrations and a greater antioxidant capacity. Additionally, significant differences between cultivars were also found. ‘Showtime’ and ‘Friar’ were the cultivars with the highest polyphenol concentration and antioxidant capacity. ‘Black Amber’ had the highest anthocyanin content and ‘Larry Ann’ and ‘Songold’ the highest carotenoid content. ‘Sapphire’ and ‘Black amber’ were the cultivars with the highest concentration of ascorbic acid. Our results showed a strong year effect. In conclusion, organic management had an impact on the production of phytochemical compounds in plums. PMID:26313546
Zhang, Y; Chu, X T; Zeng, X J; Li, H; Zhang, F C; Zhang, S Y; Shen, T
2018-06-01
Objective: To assess the value of internal medicine residency training program at Peking Union Medical College Hospital (PUMCH), and the feasibility of applying revised Milestones evaluation system. Methods: Postgraduate-year-one to four (PGY-1 to PGY-4) residents in PUMCH finished the revised Milestones evaluation scales in September 2017. Residents' self-evaluation and faculty-evaluation scores were calculated. Statistical analysis was conducted on the data. Results: A total of 207 residents were enrolled in this cross-sectional study. Both self and faculty scores showed an increasing trend in senior residents. PGY-1 residents were assessed during their first month of residency with scores of 4 points or higher, suggesting that residents have a high starting level. More strikingly, the mean score in PGY-4 was 7 points or higher, proving the career development of residency training program. There was no statistically significant difference between total self- and faculty-evaluation scores. Evaluation scores of learning ability and communication ability were lower in faculty group ( t =-2.627, -4.279, all P <0.05). The scores in graduate students were lower than those in standardized training residents. Conclusions: The goal of national standardized residency training is to improve the quality of healthcare and residents' career development. The evaluation results would guide curriculum design and emphasize the importance and necessity of multi-level teaching. Self-evaluation contributes to the understanding of training objectives and personal cognition.
Three-year clinical effectiveness of four total-etch dentinal adhesive systems in cervical lesions.
Van Meerbeek, B; Peumans, M; Gladys, S; Braem, M; Lambrechts, P; Vanherle, G
1996-11-01
A 3-year follow-up clinical trial of two experimental Bayer total-etch adhesive systems and two commercial total-etch systems. Clearfil Liner Bond System and Scotchbond Multi-Purpose, was conducted to evaluate their clinical effectiveness in Class V cervical lesions. Four hundred twenty abrasion-erosion lesions were restored randomly using the four adhesive systems. There were two experimental cavity designs, in which the adjacent enamel margins either were or were not beveled and acid etched. Clearfil Liner Bond System and Scotchbond Multi-Purpose demonstrated high retention rates in both types of cavity design at 3 years. The two experimental Bayer systems scored much lower retention rates in both cavity designs at 3 years. None of the systems guaranteed margins free of microleakage for a long time. At 3 years, superficial, localized marginal discolorations were observed, the least for Clearfil Liner Bond System, followed by Scotchbond Multi-Purpose and the two experimental systems. Small marginal defects were recorded at the cervical dentin and the incisal enamel margin. Retention of Clearfil Liner Bond and Scotchbond Multi-Purpose appears to be clearly improved over earlier systems, but marginal sealing remains problematic. The two Bayer systems were found to be clinically unreliable.
Summary of the recent short-haul systems studies
NASA Technical Reports Server (NTRS)
Savin, R. C.; Galloway, T. L.; Wilcox, D. E.; Kenyon, G. C.; Ardema, M. D.; Waters, M. H.
1975-01-01
The results of several NASA sponsored high density short haul air transportation systems studies are reported as well as analyzed. Included are the total STOL systems analysis approach, a companion STOL composites study conducted in conjunction with STOL systems studies, a STOL economic assessment study, an evaluation of STOL aircraft with and without externally blown flaps, an alternative STOL systems for the San Francisco Bay Area, and the quiet, clean experimental engine studies. Assumptions and results of these studies are summarized, their differences, analyzed, and the results compared with those in-house analyses performed by the Systems Studies Division of the NASA-Ames Research Center. Pertinent conclusions are developed and the more significant technology needs for the evaluation of a viable short haul transportation system are identified.
Lemmetty, Kaisa; Häyrinen, Eija
2005-01-01
In this paper we evaluate the implementation of the operation management system in the Central Finland Health Care District. The implementation of the operation management system changed the practice of operation management for the surgical clinic and concerned 500 personnel in total. A survey was carried out to investigate the end users' views on the system's usefulness, usability and the training and user support provided. The users' possibilities to accomplish their tasks and the kind of obstacles they face in operation management were explored. The assessment revealed that more end support is needed after the system implementation, even though a generally positive attitude towards the system was manifested among the staff.
Shelbourne, K Donald; Barnes, Adam F; Gray, Tinker
2012-11-01
Limited studies exist regarding how well a single assessment numeric evaluation (SANE) rating correlates with validated knee surveys. To determine whether a SANE rating correlates positively with the International Knee Documentation Committee (IKDC) and the modified Cincinnati Knee Rating System (CKRS) total scores after knee surgery. Cohort study (Diagnosis); Level of evidence, 2. Patients undergoing either anterior cruciate ligament (ACL) reconstruction or knee arthroscopy were prospectively given subjective evaluations yearly after surgery between January 2000 and June 2011. Subjective evaluations were obtained using modified CKRS and IKDC subjective knee surveys and a SANE rating. Interclass correlation coefficient was used to determine the correlation of the SANE rating to the survey total scores. Bland-Altman method was used to access precision and limits of agreement between scores. In addition, the data were analyzed according to sex and age categories (<18, 18-24, 25-40, >40 years). A total of 11,939 surveys were collected from 3209 patients (mean, 3.7 surveys/person; range, 1-22) after ACL reconstruction with a mean survey age of 35.2 ± 11.9 years (range, 13-72). A total of 4615 surveys were collected from 1813 patients (mean, 2.6 surveys/person; range, 1-17) after knee arthroscopy with a mean survey age of 47.4 ± 14.6 years (range, 11-88). For patients who underwent ACL reconstruction, the SANE rating had a moderate positive correlation of 0.66 to the total survey scores. For patients who underwent knee arthroscopies, the SANE rating had a strong positive correlation of 0.74 to total scores. There was minimal difference in correlations based on age group or sex. Bland-Altman analysis showed that the limits of agreement between the SANE score and the 2 surveys were met for at least 94% of patients in both patient groups. The SANE ratings exhibited moderate to strong positive correlations with the modified CKRS and IKDC subjective surveys after ACL reconstruction and knee arthroscopy for patients of all ages and both sexes.
Al Haddabi, Buthaina; Al Lawati, Haider A J; Suliman, FakhrEldin O
2017-01-01
Three recently reported microfluidic chemiluminescence (MF-CL) methods (based on reactions with acidic permanganate enhanced by formaldehyde (KMnO4-COH), acidic cerium (IV) and rhodamine B (Ce-RB), and acidic cerium (IV) and rhodamine 6G (Ce-R6G) enhanced by SDS) for the determination of the total phenolic content (TPC) in juices were critically evaluated in terms of their selectivity. The evaluation was carried out using 86 analytes, including 22 phenolic compounds (phenolic acids and polyphenols), 6 known non-phenolic antioxidants, 9 amino acids and a number of proteins, carbohydrates, nucleotide bases, inorganic salts and other compounds. Each method was sensitive toward phenolic compounds (PCs). However, the KMnO4-COH CL system showed a higher sensitivity toward phenolic acids and also responded to non-phenolic antioxidants. The other two systems showed higher sensitivity toward polyphenolic compounds than to phenolic acids and did not responded to all other compounds including non-phenolic antioxidants. Copyright © 2016 Elsevier Ltd. All rights reserved.
A cometary ion mass spectrometer
NASA Technical Reports Server (NTRS)
Shelley, E. G.; Simpson, D. A.
1984-01-01
The development of flight suitable analyzer units for that part of the GIOTTO Ion Mass Spectrometer (IMS) experiment designated the High Energy Range Spectrometer (HERS) is discussed. Topics covered include: design of the total ion-optical system for the HERS analyzer; the preparation of the design of analyzing magnet; the evaluation of microchannel plate detectors and associated two-dimensional anode arrays; and the fabrication and evaluation of two flight-suitable units of the complete ion-optical analyzer system including two-dimensional imaging detectors and associated image encoding electronics.
New Automotive Air Conditioning System Simulation Tool Developed in MATLAB/Simulink
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiss, T.; Chaney, L.; Meyer, J.
Further improvements in vehicle fuel efficiency require accurate evaluation of the vehicle's transient total power requirement. When operated, the air conditioning (A/C) system is the largest auxiliary load on a vehicle; therefore, accurate evaluation of the load it places on the vehicle's engine and/or energy storage system is especially important. Vehicle simulation software, such as 'Autonomie,' has been used by OEMs to evaluate vehicles' energy performance. A transient A/C simulation tool incorporated into vehicle simulation models would also provide a tool for developing more efficient A/C systems through a thorough consideration of the transient A/C system performance. The dynamic systemmore » simulation software Matlab/Simulink was used to develop new and more efficient vehicle energy system controls. The various modeling methods used for the new simulation tool are described in detail. Comparison with measured data is provided to demonstrate the validity of the model.« less
ERIC Educational Resources Information Center
Jackman, Andrew
This exploration of evaluation strategies for systemic educational reform considers whether there is a way to design an assessment and delivery system that can accomplish the goals of the total educational process. A basic question that must be addressed in systemic reform is the role of education in the socialization processes of society. Beyond…
ERIC Educational Resources Information Center
Meyer, R. W.; Alexander, George
This study, conducted to determine which automated system would be the most appropriate to replicate or install at Clemson University to support the users of the library, screened 29 library automation systems to determine those most adaptable to Clemson's needs. In-depth comparisons were made with regard to functions available, features, start up…
NASA Technical Reports Server (NTRS)
1976-01-01
The performance capability of each of two precision attitude determination systems (PADS), one using a strapdown star tracker, and the other using a single-axis gimbal star tracker was measured in the laboratory under simulated orbit conditions. The primary focus of the evaluation was on the contribution to the total system accuracy by the star trackers, and the effectiveness of the software algorithms in functioning with actual sensor signals. A brief description of PADS, the laboratory test configuration and the test facility, is given along with a discussion of the data handling and display, laboratory computer programs, PADS performance evaluation programs, and the strapdown and gimbal system tests. Results are presented and discussed.
Solar Energy Systems for Lunar Oxygen Generation
NASA Technical Reports Server (NTRS)
Colozza, Anthony J.; Heller, Richard S.; Wong, Wayne A.; Hepp, Aloysius F.
2010-01-01
An evaluation of several solar concentrator-based systems for producing oxygen from lunar regolith was performed. The systems utilize a solar concentrator mirror to provide thermal energy for the oxygen production process. Thermal energy to power a Stirling heat engine and photovoltaics are compared for the production of electricity. The electricity produced is utilized to operate the equipment needed in the oxygen production process. The initial oxygen production method utilized in the analysis is hydrogen reduction of ilmenite. Utilizing this method of oxygen production a baseline system design was produced. This baseline system had an oxygen production rate of 0.6 kg/hr with a concentrator mirror size of 5 m. Variations were performed on the baseline design to show how changes in the system size and process (rate) affected the oxygen production rate. An evaluation of the power requirements for a carbothermal lunar regolith reduction reactor has also been conducted. The reactor had a total power requirement between 8,320 to 9,961 W when producing 1000 kg/year of oxygen. The solar concentrator used to provide the thermal power (over 82 percent of the total energy requirement) would have a diameter of less than 4 m.
Wakeland, Wayne; Nielsen, Alexandra; Schmidt, Teresa D; McCarty, Dennis; Webster, Lynn R; Fitzgerald, John; Haddox, J David
2013-10-01
Three educational interventions were simulated in a system dynamics model of the medical use, trafficking, and nonmedical use of pharmaceutical opioids. The study relied on secondary data obtained in the literature for the period of 1995 to 2008 as well as expert panel recommendations regarding model parameters and structure. The behavior of the resulting systems-level model was tested for fit against reference behavior data. After the base model was tested, logic to represent three educational interventions was added and the impact of each intervention on simulated overdose deaths was evaluated over a 7-year evaluation period, 2008 to 2015. Principal findings were that a prescriber education intervention not only reduced total overdose deaths in the model but also reduced the total number of persons who receive opioid analgesic therapy, medical user education not only reduced overdose deaths among medical users but also resulted in increased deaths from nonmedical use, and a "popularity" intervention sharply reduced overdose deaths among nonmedical users while having no effect on medical use. System dynamics modeling shows promise for evaluating potential interventions to ameliorate the adverse outcomes associated with the complex system surrounding the use of opioid analgesics to treat pain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, T.
1993-07-01
The report summarizes the findings of an evaluation of the Basic Extractive Sludge Treatment (B.E.S.T.) solvent extraction technology developed by Resources Conservation Company (RCC). During the demonstration test, the B.E.S.T. system was used to treat composited sediments from two areas of the Grand Calumet River. Contaminant concentration reductions of 96 percent for total polynuclear aromatic hydrocarbons (PAHs) and greater than 99 percent for total polychlorinated biphenyls (PCBs) were achieved for Sediment A. Contaminant concentration reductions of greater than 99 percent for total PAHs and greater than 99 percent for total PCBs were achieved for Sediment B. Removal efficiencies in excessmore » of 98 percent were realized for both sediments for oil and grease (O G).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, T.
1993-07-01
The report summarizes the findings of an evaluation of the Basic Extractive Sludge Treatment (B.E.S.T.) solvent extraction technology developed by Resources Conservation Company (RCC). During the demonstration test, the B.E.S.T. system was used to treat composited sediments from two areas of the Grand Calumet River. Contaminant concentration reductions of 96 percent for total polynuclear aromatic hydrocarbons (PAHs) and greater than 99 percent for total polychlorinated biphenyls (PCBs) were achieved for Sediment A. Contaminant concentration reductions of greater than 99 percent for total PAHs and greater than 99 percent for total PCBs were achieved for Sediment B. Removal efficiencies in excessmore » of 98 percent were realized for both sediments for oil and grease (O G).« less
NASA Astrophysics Data System (ADS)
Wang, Hongrui; Wang, Yupeng; Ye, Xin; Yang, Dongjun; Wang, Kai; Li, Huiduan; Fang, Wei
2017-01-01
The Total Solar Irradiance Monitor (TSIM) onboard the nadir Feng Yun-3C (FY-3C) satellite provides measurements of the total solar irradiance with accurate solar tracking and sound thermal stability of its heat sink. TSIM/FY-3C mainly consists of the pointing system, the radiometer package, the thermal control system, and the electronics. Accurate solar tracking is achieved by the pointing system, which greatly improves the science data quality when compared with the previous TSIM/FY-3A and TSIM/FY-3B. The total solar irradiance (TSI) is recorded by TSIM/FY-3C about 26 times each day, using a two-channel radiometer package. One channel is used to perform routine observation, and the other channel is used to monitor the degradation of the cavity detector in the routine channel. From the results of the ground test, the incoming irradiance is measured by the routine channel (AR1) with a relative uncertainty of 592 ppm. A general description of the TSIM, including the instrument modules, uncertainty evaluation, and its operation, is given in this article.
[Ecosystem services of Chongyi Hakka Terraces].
Miao, Jian Qun; Wang, Zhi Qiang; Yang, Wen Ting; Sun, Song; Huang, Guo Qin
2017-05-18
An economic evaluation of the main ecosystem services of Chongyi Hakka Terraces can help to demonstrate the contributions of the terrace system to Hakka society, on the basis of which the protection of Hakka Terrace system could be undertaken by the local government. In view of the social and economic characteristics of Chongyi Hakka Terrace ecosystem and its location, an index system was established to evaluate the service function, and a qualitative analysis was conducted for these functions and their importance. Besides, based on the data collected in 2014, with a combination of physical quality and economic value, a quantitative analysis was carried out for its nine ser-vice indicators. The findings were as follows: firstly, among the nine evaluation indicators, the phy-sical quality and the economic value of soil conservation both ranked the highest, the former being 76457 kg·hm -2 and the latter 105033 yuan·hm -2 , accounting respectively for 72.2% and 30.0% of the total mass and total value of the Hakka Terrace ecosystem. Secondly, the unique service functions of Hakka Terrace ecosystem could be embodied in its cultural heritage and landscape, the corresponding economic values reaching up to 100000 yuan·hm -2 and 46333 yuan·hm -2 respectively, ranking the second and third highest among the nine indicators. Thirdly, the agricultural pro-ducts from the Hakka Terrace were vital welfare for the local residents, but their physical quality and the economic value only accounted for 6.1% and 10.4% of its total mass and total value respectively. As a result, the service functions of the Hakka Terrace ecosystem would be dramatically undervalued with respect to agricultural products only. These economic figures could reveal the huge contributions which the Hakka Terrace ecosystem had made to the society, not only raising awareness of the necessity to preserve the agricultural heritage by the administrators and the public, but also providing efficient data support for the government when making ecological compensation criteria for the Hakka Terrace system.
Colvin, Michael E.; Pierce, Clay; Stewart, Timothy W.
2015-01-01
Food web modeling is recognized as fundamental to understanding the complexities of aquatic systems. Ecopath is the most common mass-balance model used to represent food webs and quantify trophic interactions among groups. We constructed annual Ecopath models for four consecutive years during the first half-decade of a zebra mussel invasion in shallow, eutrophic Clear Lake, Iowa, USA, to evaluate changes in relative biomass and total system consumption among food web groups, evaluate food web impacts of non-native common carp and zebra mussels on food web groups, and to interpret food web impacts in light of on-going lake restoration. Total living biomass increased each year of the study; the majority of the increase due to a doubling in planktonic blue green algae, but several other taxa also increased including a more than two-order of magnitude increase in zebra mussels. Common carp accounted for the largest percentage of total fish biomass throughout the study even with on-going harvest. Chironomids, common carp, and zebra mussels were the top-three ranking consumer groups. Non-native common carp and zebra mussels accounted for an average of 42% of the total system consumption. Despite the relatively high biomass densities of common carp and zebra mussel, food web impacts was minimal due to excessive benthic and primary production in this eutrophic system. Consumption occurring via benthic pathways dominated system consumption in Clear Lake throughout our study, supporting the argument that benthic food webs are significant in shallow, eutrophic lake ecosystems and must be considered if ecosystem-level understanding is to be obtained.
Ferner, C; Obritzhauser, W; Fuchs, K; Schmerold, I
2014-11-01
The objective of this study was to develop and evaluate a feasible system for the collection of antimicrobial consumption data in farm animals in Austria. An electronic registry of all antibacterial pharmaceuticals approved in Austria for use in farm animals was created, listing product name, marketing authorisation number, active ingredient, package unit, strength, target species (cattle, swine, poultry), route of administration and indication, and allocating the corresponding code of the World Health Organization (WHO) Anatomical Therapeutic Chemical classification system for veterinary medicines to each substance (ATCvet-code). Different units (absolute quantities, animal daily dose, assumed daily product dose) enabled computation of the amounts of antimicrobials as pure substance, the constituents of a veterinary medicinal product, or the number of administrations. Two data collection systems were evaluated: (1) data transfer from the management software of veterinary practices or the Austrian Poultry Health Service; and (2) on-site data collection by manual data input from prescription records into an electronic registry. A total of 14,267 data sets provided by 18 practices were documented during the period January 2008 to March 2010. The total weight of active substances reported amounted to more than 5.4 tonnes for all species studied. The systems proved suitable for routine data acquisition and were considered in a recent national regulation on the surveillance of sale and consumption of veterinary antimicrobial substances. British Veterinary Association.
Methods for semi-automated indexing for high precision information retrieval.
Berrios, Daniel C; Cucina, Russell J; Fagan, Lawrence M
2002-01-01
To evaluate a new system, ISAID (Internet-based Semi-automated Indexing of Documents), and to generate textbook indexes that are more detailed and more useful to readers. Pilot evaluation: simple, nonrandomized trial comparing ISAID with manual indexing methods. Methods evaluation: randomized, cross-over trial comparing three versions of ISAID and usability survey. Pilot evaluation: two physicians. Methods evaluation: twelve physicians, each of whom used three different versions of the system for a total of 36 indexing sessions. Total index term tuples generated per document per minute (TPM), with and without adjustment for concordance with other subjects; inter-indexer consistency; ratings of the usability of the ISAID indexing system. Compared with manual methods, ISAID decreased indexing times greatly. Using three versions of ISAID, inter-indexer consistency ranged from 15% to 65% with a mean of 41%, 31%, and 40% for each of three documents. Subjects using the full version of ISAID were faster (average TPM: 5.6) and had higher rates of concordant index generation. There were substantial learning effects, despite our use of a training/run-in phase. Subjects using the full version of ISAID were much faster by the third indexing session (average TPM: 9.1). There was a statistically significant increase in three-subject concordant indexing rate using the full version of ISAID during the second indexing session (p < 0.05). Users of the ISAID indexing system create complex, precise, and accurate indexing for full-text documents much faster than users of manual methods. Furthermore, the natural language processing methods that ISAID uses to suggest indexes contributes substantially to increased indexing speed and accuracy.
Clinical Evaluation of the TITAN™ Total Shoulder System
2018-02-14
Arthritis; Arthritis, Degenerative; Rheumatoid Arthritis; Post-traumatic Arthrosis of Other Joints, Shoulder Region; Rotator Cuff Syndrome of Shoulder and Allied Disorders; Fracture; Avascular Necrosis; Joint Instability; Joint Trauma; Dislocation, Shoulder; Pain, Shoulder
Totally implantable system for peritoneal access.
Pfeifle, C E; Howell, S B; Markman, M; Lucas, W E
1984-11-01
A totally implantable system for providing access to the peritoneal cavity was evaluated. Fifty-six Port-A-Cath (Pharmacia Nu Tech, Piscataway, NJ) peritoneal access systems were implanted in 54 cancer patients receiving intraperitoneal chemotherapy. The catheters are accessed by transcutaneous placement of a Huber point needle through a silicone septum at the top of the portal. A total of 32 patient years of experience are reported. The Port-A-Caths have been in place for a median of 22 weeks (range, one to 85). A total of 401 entries have been made for paracentesis, chemotherapy administration, antibiotic administration, peritoneal lavage for cytology, and catheter flushing. There have been six episodes of peritonitis (five Staphylococcus epidermidis, one S aureus) in three patients. There have been no mechanical failures of the Port-A-Caths. Loss of bidirectional flow through the catheter due to fibrin deposition about the catheter has been the major cause of catheter failure. Patient acceptance of the Port-A-Cath has been excellent.
Singh, Avatar; Singh, Kanwar Kulwinder
2017-09-01
Advancement in technology in terms of design and building materials has made Total Knee Replacement (TKR) a highly effective, safe, and predictable orthopedic procedure. To review the clinical outcomes for efficacy and performance of Freedom Total Knee System for the management of Osteoarthritis (OA), at a minimum of three years follow up. For this retrospective, post-marketing study, clinical data of patients treated with Freedom Total Knee System was retrieved from the clinical records after approval from the Institutional Ethics Committee . All the patients above the age of 18 years who completed at least three years after TKR were observed for the study purpose. Patients treated for OA were included while the patients who received the implant for treatment of rheumatoid arthritis and traumatic injury were excluded. Factors such as aseptic loosening, implant failure, and need for revision surgery were observed to evaluate implant performance. Cases were recruited for clinical assessment of primary efficacy endpoint in terms of post-surgery maximun range of motion. Secondary efficacy endpoint was to determine the clinical and social quality of life as per the American Knee Society Score (AKSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and stiffness scores. A total of 158 patients who had 191 TKR were observed for performance. The mean age of the patients was 67.67 years; mean BMI was 28.97±3.33, and the group comprised of 43% men and 57% women. Telephonic follow up at three years of 158 patients identified that none of them required revision surgery or had aseptic loosening suggesting excellent performance. Final clinical follow up at three years was available for only 35 patients (41 knee implants). The range of motion significantly improved from preoperative 104°±5.67° (range, 85°-119°) to 119.8°±11.05° (98°-123°) at follow-up (p<0.05). There was a significant improvement in clinical and functional AKSS score and WOMAC score at follow-up. The evaluation of Freedom Total Knee System for TKR in treating OA, at a minimum of three years follow up showed excellent outcomes in terms of performance, range of motion, reduced postoperative stiffness and pain, and improved functionality.
Singh, Kanwar Kulwinder
2017-01-01
Introduction Advancement in technology in terms of design and building materials has made Total Knee Replacement (TKR) a highly effective, safe, and predictable orthopedic procedure. Aim To review the clinical outcomes for efficacy and performance of Freedom Total Knee System for the management of Osteoarthritis (OA), at a minimum of three years follow up. Materials and Methods For this retrospective, post-marketing study, clinical data of patients treated with Freedom Total Knee System was retrieved from the clinical records after approval from the Institutional Ethics Committee . All the patients above the age of 18 years who completed at least three years after TKR were observed for the study purpose. Patients treated for OA were included while the patients who received the implant for treatment of rheumatoid arthritis and traumatic injury were excluded. Factors such as aseptic loosening, implant failure, and need for revision surgery were observed to evaluate implant performance. Cases were recruited for clinical assessment of primary efficacy endpoint in terms of post-surgery maximun range of motion. Secondary efficacy endpoint was to determine the clinical and social quality of life as per the American Knee Society Score (AKSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and stiffness scores. Results A total of 158 patients who had 191 TKR were observed for performance. The mean age of the patients was 67.67 years; mean BMI was 28.97±3.33, and the group comprised of 43% men and 57% women. Telephonic follow up at three years of 158 patients identified that none of them required revision surgery or had aseptic loosening suggesting excellent performance. Final clinical follow up at three years was available for only 35 patients (41 knee implants). The range of motion significantly improved from preoperative 104°±5.67° (range, 85°-119°) to 119.8°±11.05° (98°-123°) at follow-up (p<0.05). There was a significant improvement in clinical and functional AKSS score and WOMAC score at follow-up. Conclusion The evaluation of Freedom Total Knee System for TKR in treating OA, at a minimum of three years follow up showed excellent outcomes in terms of performance, range of motion, reduced postoperative stiffness and pain, and improved functionality. PMID:29207792
Semantic and Phonemic Verbal Fluency in Blinds
ERIC Educational Resources Information Center
Nejati, Vahid; Asadi, Anoosh
2010-01-01
A person who has suffered the total loss of a sensory system has, indirectly, suffered a brain lesion. Semantic and phonologic verbal fluency are used for evaluation of executive function and language. The aim of this study is evaluation and comparison of phonemic and semantic verbal fluency in acquired blinds. We compare 137 blinds and 124…
Spacecraft systems engineering: An introduction to the process at GSFC
NASA Technical Reports Server (NTRS)
Fragomeni, Tony; Ryschkewitsch, Michael G.
1993-01-01
The main objective in systems engineering is to devise a coherent total system design capable of achieving the stated requirements. Requirements should be rigid. However, they should be continuously challenged, rechallenged and/or validated. The systems engineer must specify every requirement in order to design, document, implement and conduct the mission. Each and every requirement must be logically considered, traceable and evaluated through various analysis and trade studies in a total systems design. Margins must be determined to be realistic as well as adequate. The systems engineer must also continuously close the loop and verify system performance against the requirements. The fundamental role of the systems engineer, however, is to engineer, not manage. Yet, in large, complex missions, where more than one systems engineer is required, someone needs to manage the systems engineers, and we call them 'systems managers.' Systems engineering management is an overview function which plans, guides, monitors and controls the technical execution of a project as implemented by the systems engineers. As the project moves on through Phases A and B into Phase C/D, the systems engineering tasks become a small portion of the total effort. The systems management role increases since discipline subsystem engineers are conducting analyses and reviewing test data for final review and acceptance by the systems managers.
Caldwell, John T.; Kunz, Walter E.; Cates, Michael R.; Franks, Larry A.
1985-01-01
Simultaneous photon and neutron interrogation of samples for the quantitative determination of total fissile nuclide and total fertile nuclide material present is made possible by the use of an electron accelerator. Prompt and delayed neutrons produced from resulting induced fissions are counted using a single detection system and allow the resolution of the contributions from each interrogating flux leading in turn to the quantitative determination sought. Detection limits for .sup.239 Pu are estimated to be about 3 mg using prompt fission neutrons and about 6 mg using delayed neutrons.
Caldwell, J.T.; Kunz, W.E.; Cates, M.R.; Franks, L.A.
1982-07-07
Simultaneous photon and neutron interrogation of samples for the quantitative determination of total fissile nuclide and total fertile nuclide material present is made possible by the use of an electron accelerator. Prompt and delayed neutrons produced from resulting induced fission are counted using a single detection system and allow the resolution of the contributions from each interrogating flux leading in turn to the quantitative determination sought. Detection limits for /sup 239/Pu are estimated to be about 3 mg using prompt fission neutrons and about 6 mg using delayed neutrons.
Field Artillery Ammunition Processing System (FAAPS) concept evaluation study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kring, C.T.; Babcock, S.M.; Watkin, D.C.
1992-06-01
The Field Artillery Ammunition Processing System (FAAPS) is an initiative to introduce a palletized load system (PLS) that is transportable with an automated ammunition processing and storage system for use on the battlefield. System proponents have targeted a 20% increase in the ammunition processing rate over the current operation while simultaneously reducing the total number of assigned field artillery battalion personnel by 30. The overall objective of the FAAPS Project is the development and demonstration of an improved process to accomplish these goals. The initial phase of the FAAPS Project and the subject of this study is the FAAPS conceptmore » evaluation. The concept evaluation consists of (1) identifying assumptions and requirements, (2) documenting the process flow, (3) identifying and evaluating technologies available to accomplish the necessary ammunition processing and storage operations, and (4) presenting alternative concepts with associated costs, processing rates, and manpower requirements for accomplishing the operation. This study provides insight into the achievability of the desired objectives.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kring, C.T.; Babcock, S.M.; Watkin, D.C.
1992-06-01
The Field Artillery Ammunition Processing System (FAAPS) is an initiative to introduce a palletized load system (PLS) that is transportable with an automated ammunition processing and storage system for use on the battlefield. System proponents have targeted a 20% increase in the ammunition processing rate over the current operation while simultaneously reducing the total number of assigned field artillery battalion personnel by 30. The overall objective of the FAAPS Project is the development and demonstration of an improved process to accomplish these goals. The initial phase of the FAAPS Project and the subject of this study is the FAAPS conceptmore » evaluation. The concept evaluation consists of (1) identifying assumptions and requirements, (2) documenting the process flow, (3) identifying and evaluating technologies available to accomplish the necessary ammunition processing and storage operations, and (4) presenting alternative concepts with associated costs, processing rates, and manpower requirements for accomplishing the operation. This study provides insight into the achievability of the desired objectives.« less
Evaluation of solar sludge drying alternatives by costs and area requirements.
Kurt, Mayıs; Aksoy, Ayşegül; Sanin, F Dilek
2015-10-01
Thermal drying is a common method to reach above 90% dry solids content (DS) in sludge. However, thermal drying requires high amount of energy and can be expensive. A greenhouse solar dryer (GSD) can be a cost-effective substitute if the drying performance, which is typically 70% DS, can be increased by additional heat. In this study feasibility of GSD supported with solar panels is evaluated as an alternative to thermal dryers to reach 90% DS. Evaluations are based on capital and O&M costs as well as area requirements for 37 wastewater treatment plants (WWTPs) with various sludge production rates. Costs for the supported GSD system are compared to that of conventional and co-generation thermal dryers. To calculate the optimal costs associated with the drying system, an optimization model was developed in which area limitation was a constraint. Results showed that total cost was minimum when the DS in the GSD (DS(m,i)) was equal to the maximum attainable value (70% DS). On average, 58% of the total cost and 38% of total required area were associated with the GSD. Variations in costs for 37 WWTPs were due to differences in initial DS (DS(i,i)) and sludge production rates, indicating the importance of dewatering to lower drying costs. For large plants, GSD supported with solar panels provided savings in total costs especially in long term when compared to conventional and co-generation thermal dryers. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Nugraha, W. C.; Elishian, C.; Ketrin, R.
2017-03-01
Fish containing arsenic compound is one of the important indicators of arsenic contamination in water monitoring. The high level of arsenic in fish is due to absorption through food chain and accumulated in their habitat. Hydride generation (HG) coupled with atomic absorption spectrometric (AAS) detection is one of the most popular techniques employed for arsenic determination in a variety of matrices including fish. This study aimed to develop a method for the determination of total arsenic in fish by HG-AAS. The method for sample preparation from American of Analytical Chemistry (AOAC) Method 999.10-2005 was adopted for acid digestion using microwave digestion system and AOAC Method 986.15 - 2005 for dry ashing. The method was developed and validated using Certified Reference Material DORM 3 Fish Protein for trace metals for ensuring the accuracy and the traceability of the results. The sources of uncertainty of the method were also evaluated. By using the method, it was found that the total arsenic concentration in the fish was 45.6 ± 1.22 mg.Kg-1 with a coverage factor of equal to 2 at 95% of confidence level. Evaluation of uncertainty was highly influenced by the calibration curve. This result was also traceable to International Standard System through analysis of Certified Reference Material DORM 3 with 97.5% of recovery. In summary, it showed that method of preparation and HG-AAS technique for total arsenic determination in fish were valid and reliable.
Operating rules for multireservoir systems
NASA Astrophysics Data System (ADS)
Oliveira, Rodrigo; Loucks, Daniel P.
1997-04-01
Multireservoir operating policies are usually defined by rules that specify either individual reservoir desired (target) storage volumes or desired (target) releases based on the time of year and the existing total storage volume in all reservoirs. This paper focuses on the use of genetic search algorithms to derive these multireservoir operating policies. The genetic algorithms use real-valued vectors containing information needed to define both system release and individual reservoir storage volume targets as functions of total storage in each of multiple within-year periods. Elitism, arithmetic crossover, mutation, and "en bloc" replacement are used in the algorithms to generate successive sets of possible operating policies. Each policy is then evaluated using simulation to compute a performance index for a given flow series. The better performing policies are then used as a basis for generating new sets of possible policies. The process of improved policy generation and evaluation is repeated until no further improvement in performance is obtained. The proposed algorithm is applied to example reservoir systems used for water supply and hydropower.
The EnSys Petro Test System developed by Strategic Diagnostics Inc. (SDI), was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The...
USDA-ARS?s Scientific Manuscript database
The low-energy recirculating aquaculture system consists of nine separate modules which utilize the double drain fish culture tank paired to a moving bed biofilter. The nine fiberglass tanks are five feet in diameter and normal water depth is about three feet for a total tank volume of approximately...
Gökakın, Ali Kağan; Atabey, Mustafa; Deveci, Koksal; Sancakdar, Enver; Tuzcu, Mehmet; Duger, Cevdet; Topcu, Omer
2014-09-01
Severe burn induces systemic inflammation and reactive oxygen species leading to lipid peroxidation which may play role in remote organs injury. Sildenafil is a selective and potent inhibitor of cyclic guanosine monophosphate specific phosphodiesterase-5. Sildenafil reduces oxidative stress and inflammation in distant organs. The aim of the present study was to evaluate the effects of different dosages of sildenafil in remote organs injury. A total of thirty-two rats were randomly divided into four equal groups. The groups were designated as follows: Sham, Control, 10, and T20 mg/kg sildenafil treatment groups. Levels of malondialdehyde (MDA), vascular endothelial growth factor (VEGF), VEGF receptor (Flt-1), activities of glutathione peroxidase (Gpx), levels of total antioxidative capacity (TAC), and total oxidant status (TOS) were measured in both tissues and serum, and a semi-quantitative scoring system was used for the evaluation of histopathological findings. Sildenafil increased levels of Gpx, and Flt-1, and decreased MDA and VEGF levels in tissues. Sildenafil also increased serum levels of TAC and Flt-1 and decreased TOS, OSI, and VEGF. Sildenafil decreased inflammation scores in remote organs in histopathological evaluation. It has protective effects in severe burn-related remote organ injuries by decreasing oxidative stress and inflammation.
NASA Technical Reports Server (NTRS)
Muller, Matthew S.; Bauer, Clarence F.
1994-01-01
Performance of NASA's prototype CELSS Breadboard Project Closed Aquaculture System was evaluated by estimating gas exchange quantification and preliminary carbon and nitrogen balances. The total system oxygen consumption rate was 535 mg/hr kg/fish (cv = 30%) when stocked with Tilapia aurea populations (fresh weights of 97 +/- 19 to 147 +/- 36 g/fish for various trials). Oxygen consumption by T. aurea (260 mg/hr kg/fish) contributed to approximately one-half of total system demand. Continuous carbon dioxide quantification methods were analyzed using the,relation of carbon dioxide to oxygen consumption. Overall food conversion rates averaged 18.2 +/- 3.2%. Major pathways for nitrogen and carbon in the system were described with preliminary mass closure of 60-80% and 60% for nitrogen and carbon.
Hybrid and concatenated coding applications.
NASA Technical Reports Server (NTRS)
Hofman, L. B.; Odenwalder, J. P.
1972-01-01
Results of a study to evaluate the performance and implementation complexity of a concatenated and a hybrid coding system for moderate-speed deep-space applications. It is shown that with a total complexity of less than three times that of the basic Viterbi decoder, concatenated coding improves a constraint length 8 rate 1/3 Viterbi decoding system by 1.1 and 2.6 dB at bit error probabilities of 0.0001 and one hundred millionth, respectively. With a somewhat greater total complexity, the hybrid coding system is shown to obtain a 0.9-dB computational performance improvement over the basic rate 1/3 sequential decoding system. Although substantial, these complexities are much less than those required to achieve the same performances with more complex Viterbi or sequential decoder systems.
Study on the influence on water ecosystem by a lake inflow filtration system
NASA Astrophysics Data System (ADS)
Wu, Sushu; Gao, Shipei; Hu, Xiaodong; Weng, Songgan; Guo, Liuchao
2018-06-01
Lakes play important roles in the economic-social sustainable development. However, due to unreasonable development and urbanization in recent years, lake water pollution and ecological degradation have occurred in China. The improvement of the lake inflow water quality is very important. A filtration system includes Gravel filtering system, Aquatic plant area and Ecological bag area was established. The test river is one of the typical lake inflow river and located in the river network in the Chang Dang lake, China. Water quality, zooplankton and phytoplankton in the inflow river were observed form July to mid-August in order to analyze the general process. The average removal rate of NH3-N (ammonia nitrogen) TN (total nitrogen) and TP (total phosphorus) is 28.33, 25.76 and 24.43 %, respectively. The Pantle-Buck method was used to evaluate the water quality and the B/T index was used to evaluate the nutrition situation. The B/T values were reduced by 20 % and the SI pollution index was reduced by 11.8 %. Therefore, a positive effect on the water's ecological restoration was achieved by the filtration system.
Bykov, A T; Konovalova, M P; Khodasevich, L S
2009-01-01
A total of 55 patients with angina of effort (functional classes I-II) were treated by magneto-peloidotherapy and hydrogen sulfide baths. Effectiveness of he treatment was evaluated based on the lipid profile (total cholesterol, triglycerides, high and low density lipoproteides), atherogenicity index, lipid peroxidation, reactivity of the antioxidative defense system, and immune characteristics. Results of the study indicate that combination of magneto-peloidotherapy and hydrogen sulfide baths has hypolipidemic effect and reduces lipid peroxidation in the absence of activation of the antioxidative defense system and correction of the disbalanced immune system. Taken together, these effects decrease severity of the systemic inflammatory reaction and facilitate remission of the atherosclerotic process.
USDA-ARS?s Scientific Manuscript database
A 4-unit dual-flow continuous culture fermentor system was used to evaluate the effects of herbage, a total mixed ration (TMR) and flaxseed on nutrient digestibility and microbial N synthesis. Treatments were randomly assigned to fermentors in a 4 x 4 Latin square design. Each fermentor was fed a to...
Agnisarman, Sruthy; Narasimha, Shraddhaa; Chalil Madathil, Kapil; Welch, Brandon; Brinda, Fnu; Ashok, Aparna; McElligott, James
2017-04-24
Telemedicine is the use of technology to provide and support health care when distance separates the clinical service and the patient. Home-based telemedicine systems involve the use of such technology for medical support and care connecting the patient from the comfort of their homes with the clinician. In order for such a system to be used extensively, it is necessary to understand not only the issues faced by the patients in using them but also the clinician. The aim of this study was to conduct a heuristic evaluation of 4 telemedicine software platforms-Doxy.me, Polycom, Vidyo, and VSee-to assess possible problems and limitations that could affect the usability of the system from the clinician's perspective. It was found that 5 experts individually evaluated all four systems using Nielsen's list of heuristics, classifying the issues based on a severity rating scale. A total of 46 unique problems were identified by the experts. The heuristics most frequently violated were visibility of system status and Error prevention amounting to 24% (11/46 issues) each. Esthetic and minimalist design was second contributing to 13% (6/46 issues) of the total errors. Heuristic evaluation coupled with a severity rating scale was found to be an effective method for identifying problems with the systems. Prioritization of these problems based on the rating provides a good starting point for resolving the issues affecting these platforms. There is a need for better transparency and a more streamlined approach for how physicians use telemedicine systems. Visibility of the system status and speaking the users' language are keys for achieving this. ©Sruthy Agnisarman, Shraddhaa Narasimha, Kapil Chalil Madathil, Brandon Welch, FNU Brinda, Aparna Ashok, James McElligott. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 24.04.2017.
Luo, Ruiling; Yao, Xincheng; Liu, Xieying; Zhang, Yushang; Ying, Xue
2018-03-01
Coreopsis tinctoria flowering tops (CTFs) is a popular health product as herbal tea or as a traditional medicinal herb that is rich in saponins and exerts substantial biological activity. In this study, an ultrasound-assisted aqueous two-phase system (ATPS) was utilized to extract total saponins from CTFs and optimize the extraction process by response surface methodology. Moreover, the nitric oxide and nitrite scavenging capability, and N-nitrosamine formation inhibitory activity of total saponins were evaluated. Results showed that the optimal conditions for total saponins were 37.76% (w/w) ammonium sulfate and 35.62% (w/w) ethanol in ATPS coupled with ultrasonic-assisted extraction. Under the optimal conditions, the maximum yield of total saponins of 33.4 g/kg can be obtained from the CTFs raw material. The nitric oxide radical scavenging, nitrite scavenging, and N-nitrosamine inhibitory activities (SC 50 ) were 287.92 ± 7.42, 191.63 ± 7.69, and 1787.4 ± 51.26 μg/mL, respectively. The total saponins has a certain nitric oxide and nitrite scavenging capability, and N-nitrosamine formation inhibitory activity in vitro. Given these activities, research on saponins from CTFs provides profound and lasting implications for the novel applications of C. tinctoria.
A new infant hybrid respiratory simulator: preliminary evaluation based on clinical data.
Stankiewicz, Barbara; Pałko, Krzysztof J; Darowski, Marek; Zieliński, Krzysztof; Kozarski, Maciej
2017-11-01
A new hybrid (numerical-physical) simulator of the respiratory system, designed to simulate spontaneous and artificial/assisted ventilation of preterm and full-term infants underwent preliminary evaluation. A numerical, seven-compartmental model of the respiratory system mechanics allows the operator to simulate global and peripheral obstruction and restriction of the lungs. The physical part of the simulator is a piston-based construction of impedance transformer. LabVIEW real-time software coordinates the work of both parts of the simulator and its interaction with a ventilator. Using clinical data, five groups of "artificial infants" were examined: healthy full-term infants, very low-birth-weight preterm infants successfully (VLBW) and unsuccessfully extubated (VLBWun) and extremely low-birth-weight preterm infants without (ELBW) and with bronchopulmonary dysplasia (ELBW_BPD). Pressure-controlled ventilation was simulated to measure peak inspiratory pressure, mean airway pressure, total (patient + endotracheal tube) airway resistance (R), total dynamic compliance of the respiratory system (C), and total work of breathing by the ventilator (WOB). The differences between simulation and clinical parameters were not significant. High correlation coefficients between both types of data were obtained for R, C, and WOB (γ R = 0.99, P < 0.0005; γ C = 0.85, P < 0.005; γ WOB = 0.96, P < 0.05, respectively). Thus, the simulator accurately reproduces infant respiratory system mechanics.
Hypervelocity Technology Escape System Concepts. Volume 1. Development and Evaluation
1988-07-01
airplane escape systems. These include separation at high dynamic pressure, stability, impact attenuation , crew member accelerations, adequate...changes (TTS; 0 Shock attenuator design PTS) 0 Restraint system design * Limb flail * Non-auditory changes (gag, dec. visual acuity) * Reduced psycho-motor...detected by ultrasonic technique. The DCS symptoms may not appear until at slightly lower total pressures (8 N psia - 9 pals). Since the pressurization
Miyashita, Shin-Ichi; Mitsuhashi, Hiroaki; Fujii, Shin-Ichiro; Takatsu, Akiko; Inagaki, Kazumi; Fujimoto, Toshiyuki
2017-02-01
In order to facilitate reliable and efficient determination of both the particle number concentration (PNC) and the size of nanoparticles (NPs) by single-particle ICP-MS (spICP-MS) without the need to correct for the particle transport efficiency (TE, a possible source of bias in the results), a total-consumption sample introduction system consisting of a large-bore, high-performance concentric nebulizer and a small-volume on-axis cylinder chamber was utilized. Such a system potentially permits a particle TE of 100 %, meaning that there is no need to include a particle TE correction when calculating the PNC and the NP size. When the particle TE through the sample introduction system was evaluated by comparing the frequency of sharp transient signals from the NPs in a measured NP standard of precisely known PNC to the particle frequency for a measured NP suspension, the TE for platinum NPs with a nominal diameter of 70 nm was found to be very high (i.e., 93 %), and showed satisfactory repeatability (relative standard deviation of 1.0 % for four consecutive measurements). These results indicated that employing this total consumption system allows the particle TE correction to be ignored when calculating the PNC. When the particle size was determined using a solution-standard-based calibration approach without an NP standard, the particle diameters of platinum and silver NPs with nominal diameters of 30-100 nm were found to agree well with the particle diameters determined by transmission electron microscopy, regardless of whether a correction was performed for the particle TE. Thus, applying the proposed system enables NP size to be accurately evaluated using a solution-standard-based calibration approach without the need to correct for the particle TE.
Sakwari, Gloria; Mamuya, Simon H D; Bråtveit, Magne; Larsson, Lennart; Pehrson, Christina; Moen, Bente E
2013-03-01
Endotoxin exposure associated with organic dust exposure has been studied in several industries. Coffee cherries that are dried directly after harvest may differ in dust and endotoxin emissions to those that are peeled and washed before drying. The aim of this study was to measure personal total dust and endotoxin levels and to evaluate their determinants of exposure in coffee processing factories. Using Sidekick Casella pumps at a flow rate of 2l/min, total dust levels were measured in the workers' breathing zone throughout the shift. Endotoxin was analyzed using the kinetic chromogenic Limulus amebocyte lysate assay. Separate linear mixed-effects models were used to evaluate exposure determinants for dust and endotoxin. Total dust and endotoxin exposure were significantly higher in Robusta than in Arabica coffee factories (geometric mean 3.41 mg/m(3) and 10 800 EU/m(3) versus 2.10 mg/m(3) and 1400 EU/m(3), respectively). Dry pre-processed coffee and differences in work tasks explained 30% of the total variance for total dust and 71% of the variance for endotoxin exposure. High exposure in Robusta processing is associated with the dry pre-processing method used after harvest. Dust and endotoxin exposure is high, in particular when processing dry pre-processed coffee. Minimization of dust emissions and use of efficient dust exhaust systems are important to prevent the development of respiratory system impairment in workers.
NASA Astrophysics Data System (ADS)
Elyza Muha, Norshafa; Mohd Sidek, Lariyah; Jajarmizadeh, Milad
2016-03-01
Bioretention system is introduced as an important topic namely Urban Storm Water Management Manual for Malaysia (MSMA) by the Department of Irrigation and Drainage Malaysia (DID) in May 2012. The main objective of this paper is to evaluate the performance of water quality for small scale bioretention system under tropical climate via MUSIC model. Two bioretention systems 1 and 2 are observed based on the difference media depth. The result of bioretention system is compared with a reference model which has infrastructure with Urban Stormwater Improvement Conceptualisation (MUSIC) for pollutants load reduction and water quality results. Assessment of results via MUSIC software indicates a significant percentage of reduction for Total Suspended Solid (TSS), Total Phosphorus (TP) and Total Nitrogen (TN). The prediction of pollutant reduction via using MUSIC has the harmony for requirement in MSMA. TSS pollutant reduction is more than 80%, while for TP and TN more than 50%. The outcome of this study can be helpful for improvement of the existing MSMA guidelines for application of bioretention systems in Malaysia.
Mechanism and design of intermittent aeration activated sludge process for nitrogen removal.
Hanhan, Oytun; Insel, Güçlü; Yagci, Nevin Ozgur; Artan, Nazik; Orhon, Derin
2011-01-01
The paper provided a comprehensive evaluation of the mechanism and design of intermittent aeration activated sludge process for nitrogen removal. Based on the specific character of the process the total cycle time, (T(C)), the aerated fraction, (AF), and the cycle time ratio, (CTR) were defined as major design parameters, aside from the sludge age of the system. Their impact on system performance was evaluated by means of process simulation. A rational design procedure was developed on the basis of basic stochiometry and mass balance related to the oxidation and removal of nitrogen under aerobic and anoxic conditions, which enabled selected of operation parameters of optimum performance. The simulation results indicated that the total nitrogen level could be reduced to a minimum level by appropriate manipulation of the aerated fraction and cycle time ratio. They also showed that the effluent total nitrogen could be lowered to around 4.0 mgN/L by adjusting the dissolved oxygen set-point to 0.5 mg/L, a level which promotes simultaneous nitrification and denitrification.
Evaluation of Multi-Level Support Structure Requirements for New Weapon Systems.
1987-09-01
transformer 1 total consumed manhours on this level 19.45 hrs average manhrs within 4 weeks on this level : .38 hrs average rounded number of mainten; personal ...major unit data to provide conclusions about the logistics behavior of failing weapon systems. The modeling of system behavior with CAESAR has severa-l...characteristic data and major unit data to provide conclusions about the logistics behavior of failing weapon systems. The modelling of system behavior
Davidson, Carolyn; Steinberg, Daniel; Margolis, Robert
2015-02-04
We report that over the past several years, third-party-ownership (TPO) structures for residential photovoltaic (PV) systems have become the predominant ownership model in the US residential market. Under a TPO contract, the PV system host typically makes payments to the third-party owner of the system. Anecdotal evidence suggests that the total TPO contract payments made by the customer can differ significantly from payments in which the system host directly purchases the system. Furthermore, payments can vary depending on TPO contract structure. To date, a paucity of data on TPO contracts has precluded studies evaluating trends in TPO contract cost. Thismore » study relies on a sample of 1113 contracts for residential PV systems installed in 2010–2012 under the California Solar Initiative to evaluate how the timing of payments under a TPO contract impacts the ultimate cost of the system to the customer. Furthermore, we evaluate how the total cost of TPO systems to customers has changed through time, and the degree to which contract costs have tracked trends in the installed costs of a PV system. We find that the structure of the contract and the timing of the payments have financial implications for the customer: (1) power-purchase contracts, on average, cost more than leases, (2) no-money-down contracts are more costly than prepaid contracts, assuming a customer's discount rate is lower than 17% and (3) contracts that include escalator clauses cost more, for both power-purchase agreements and leases, at most plausible discount rates. Additionally, all contract costs exhibit a wide range, and do not parallel trends in installed costs over time.« less
NASA Astrophysics Data System (ADS)
Davidson, Carolyn; Steinberg, Daniel; Margolis, Robert
2015-02-01
Over the past several years, third-party-ownership (TPO) structures for residential photovoltaic (PV) systems have become the predominant ownership model in the US residential market. Under a TPO contract, the PV system host typically makes payments to the third-party owner of the system. Anecdotal evidence suggests that the total TPO contract payments made by the customer can differ significantly from payments in which the system host directly purchases the system. Furthermore, payments can vary depending on TPO contract structure. To date, a paucity of data on TPO contracts has precluded studies evaluating trends in TPO contract cost. This study relies on a sample of 1113 contracts for residential PV systems installed in 2010-2012 under the California Solar Initiative to evaluate how the timing of payments under a TPO contract impacts the ultimate cost of the system to the customer. Furthermore, we evaluate how the total cost of TPO systems to customers has changed through time, and the degree to which contract costs have tracked trends in the installed costs of a PV system. We find that the structure of the contract and the timing of the payments have financial implications for the customer: (1) power-purchase contracts, on average, cost more than leases, (2) no-money-down contracts are more costly than prepaid contracts, assuming a customer’s discount rate is lower than 17% and (3) contracts that include escalator clauses cost more, for both power-purchase agreements and leases, at most plausible discount rates. In addition, all contract costs exhibit a wide range, and do not parallel trends in installed costs over time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davidson, Carolyn; Steinberg, Daniel; Margolis, Robert
We report that over the past several years, third-party-ownership (TPO) structures for residential photovoltaic (PV) systems have become the predominant ownership model in the US residential market. Under a TPO contract, the PV system host typically makes payments to the third-party owner of the system. Anecdotal evidence suggests that the total TPO contract payments made by the customer can differ significantly from payments in which the system host directly purchases the system. Furthermore, payments can vary depending on TPO contract structure. To date, a paucity of data on TPO contracts has precluded studies evaluating trends in TPO contract cost. Thismore » study relies on a sample of 1113 contracts for residential PV systems installed in 2010–2012 under the California Solar Initiative to evaluate how the timing of payments under a TPO contract impacts the ultimate cost of the system to the customer. Furthermore, we evaluate how the total cost of TPO systems to customers has changed through time, and the degree to which contract costs have tracked trends in the installed costs of a PV system. We find that the structure of the contract and the timing of the payments have financial implications for the customer: (1) power-purchase contracts, on average, cost more than leases, (2) no-money-down contracts are more costly than prepaid contracts, assuming a customer's discount rate is lower than 17% and (3) contracts that include escalator clauses cost more, for both power-purchase agreements and leases, at most plausible discount rates. Additionally, all contract costs exhibit a wide range, and do not parallel trends in installed costs over time.« less
Sharafeddin, Farahnaz; Farhadpour, Hajar
2015-01-01
Statement of the Problem Hemostatic agents may influence the bond strength of different bonding agents. Also, chlorhexidine has shown positive effects on bond strength values and their combination effect has not been reported yet. Purpose The aim of this study was to evaluate the effect of contamination with a hemostatic agent on shear bond strength (SBS) of total- and self-etching adhesive systems and the effect of chlorhexidine application after removal of the hemostatic agent. Materials and Method In this experimental study, the occlusal enamel of each sixty caries-free mandibular molars was removed and their midcoronal dentin was exposed. The specimens were then mounted in auto-polymerizing resin 1mm apical to CEJ. Then, the specimens were divided into 6 groups (n=10) based on contamination with a hemostatic agent (H), application of chlorhexidine (CHX) and the adhesive system used; and then were classified as Group 1: Adper Single Bond (ASB); Group 2: H+ASB; Group 3: H+0.2% CHX+ASB; Group 4: Clearfil SE Bond (CSB); Group 5: H+CSB; Group 6: H+0.2% CHX+CSB. Then, composite resin rods (4×2 mm) were built up on the dentin surfaces and after thermocycling, the SBS (MPa) was evaluated. Statistical analysis was performed using two-way ANOVA and post hoc Tukey tests (p< 0.05). Results There were statistically significant differences between bond strength values of group 1 (ASB) and group 2 (H+ASB) (p< 0.001) and group 1 (ASB) and group 3 (H+CHX+ASB) (p< 0.001). Similarly, significant differences were seen between group 4 (CSB) and group 5 (H+CSB) (p< 0.001) and between group 4 (CSB) and group 6 (H+CHX+CSB) (p< 0.001). Conclusion Contamination with hemostatic agent reduced the SBS of both total- and self-etching adhesive systems. In addition, application of chlorhexidine after the removal of hemostatic agent had a negative effect on SBS of total- and self-etching adhesive systems. PMID:26331146
NASA Astrophysics Data System (ADS)
Ren, L.
2016-12-01
As a comprehensive system, there are many subsystems such as water resource subsystem, social subsystem, economic subsystem and ecological subsystem in water resource sustainable utilization system. In this paper, an evaluation system including three levels is set up according to the metric demands of sustainable water resource utilization in Jiangsu coast reclamation region, namely the target level, the rule level, and the index level. Considering the large number of the indexes, the analytic hierarchy process is used to determine the weights of all these subsystems in the total goal of water sustainable utilization. By analyzing these weights, the attributes of water resource itself is found to be the most important aspect for the evaluation of sustainable utilization in Jiangsu coast reclamation region, and the second important aspect is the situation of the eco-environment.
Computerization of a preanesthetic evaluation and user satisfaction evaluation.
Arias, Antonio; Benítez, Sonia; Canosa, Daniela; Borbolla, Damián; Staccia, Gustavo; Plazzotta, Fernando; Casais, Marcela; Michelangelo, Hernán; Luna, Daniel; Bernaldo de Quirós, Fernán Gonzalez
2010-01-01
Preanesthetic evaluation purpose is to reduce morbidity and mortality through the review of the patient's medical history, clinical examination, and targeted clinical studies, providing referrals for medical consultations when appropriated. Changes in patient care, standards of health information management and patterns of perioperative care, have resulted in a re-conceptualization of this process where the documentation of patient medical information, the efforts in training and maintaining the integrity of the medical-legal evaluation are areas of concern. The aim of this paper is to describe the design, development, training, and implementation of a computerized preanesthetic evaluation form associated to the evaluation of the user satisfaction with the system. Since the system went live in September 2008 there were 15121 closed structured forms, 60% for ambulatory procedures and 40 % for procedures that required hospital admission. 82% of total closed structured forms had recorded a risk of the procedures of 1-2, according to the American Society of Anesthesiologists classification. The survey indicates a positive general satisfaction of the users with the system.
Development and evaluation of an instrumented linkage system for total knee surgery.
Walker, Peter S; Wei, Chih-Shing; Forman, Rachel E; Balicki, M A
2007-10-01
The principles and application of total knee surgery using optical tracking have been well demonstrated, but electromagnetic tracking may offer further advantages. We asked whether an instrumented linkage that attaches directly to the bone can maintain the accuracy of the optical and electromagnetic systems but be quicker, more convenient, and less expensive to use. Initial testing using a table-mounted digitizer to navigate a drill guide for placing pins to mount a cutting guide demonstrated the feasibility in terms of access and availability. A first version (called the Mark 1) instrumented linkage designed to fix directly to the bone was constructed and software was written to carry out a complete total knee replacement procedure. The results showed the system largely fulfilled these goals, but some surgeons found that using a visual display for pin placement was difficult and time consuming. As a result, a second version of a linkage system (called the K-Link) was designed to further develop the concept. User-friendly flexible software was developed for facilitating each step quickly and accurately while the placement of cutting guides was facilitated. We concluded that an instrumented linkage system could be a useful and potentially lower-cost option to the current systems for total knee replacement and could possibly have application to other surgical procedures.
MANPRINT Methods Monograph: Aiding the Development of Manned System Performance Criteria
1989-06-01
the need for the new system. It may be necessary co derive these requirements from combat models. By modeling the capabilities of the current force ...FORMAT The O&O Plan describes how a system will be integrated into the force structure, deployed, operated, and supported in peacetime and wartime...for evaluation during OT I. 9. MANPOWER/ FORCE STRUCTURE ASSESSMENT. Estimate manpower require- ments per system, using unit, and total Army by
Reliability Evaluation of Machine Center Components Based on Cascading Failure Analysis
NASA Astrophysics Data System (ADS)
Zhang, Ying-Zhi; Liu, Jin-Tong; Shen, Gui-Xiang; Long, Zhe; Sun, Shu-Guang
2017-07-01
In order to rectify the problems that the component reliability model exhibits deviation, and the evaluation result is low due to the overlook of failure propagation in traditional reliability evaluation of machine center components, a new reliability evaluation method based on cascading failure analysis and the failure influenced degree assessment is proposed. A direct graph model of cascading failure among components is established according to cascading failure mechanism analysis and graph theory. The failure influenced degrees of the system components are assessed by the adjacency matrix and its transposition, combined with the Pagerank algorithm. Based on the comprehensive failure probability function and total probability formula, the inherent failure probability function is determined to realize the reliability evaluation of the system components. Finally, the method is applied to a machine center, it shows the following: 1) The reliability evaluation values of the proposed method are at least 2.5% higher than those of the traditional method; 2) The difference between the comprehensive and inherent reliability of the system component presents a positive correlation with the failure influenced degree of the system component, which provides a theoretical basis for reliability allocation of machine center system.
Partial and total actuator faults accommodation for input-affine nonlinear process plants.
Mihankhah, Amin; Salmasi, Farzad R; Salahshoor, Karim
2013-05-01
In this paper, a new fault-tolerant control system is proposed for input-affine nonlinear plants based on Model Reference Adaptive System (MRAS) structure. The proposed method has the capability to accommodate both partial and total actuator failures along with bounded external disturbances. In this methodology, the conventional MRAS control law is modified by augmenting two compensating terms. One of these terms is added to eliminate the nonlinear dynamic, while the other is reinforced to compensate the distractive effects of the total actuator faults and external disturbances. In addition, no Fault Detection and Diagnosis (FDD) unit is needed in the proposed method. Moreover, the control structure has good robustness capability against the parameter variation. The performance of this scheme is evaluated using a CSTR system and the results were satisfactory. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
Study of the impact of automation on productivity in bus-maintenance facilities. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sumanth, D.J.; Weiss, H.J.; Adya, B.
1988-12-01
Whether or not the various types of automation and new technologies introduced in a bus-transit system really have an impact on productivity is the question addressed in the study. The report describes a new procedure of productivity measurement and evaluation for a county-transit system and provides an objective perspective on the impact of automation on productivity in bus maintenance facilities. The research objectives were: to study the impact of automation on total productivity in transit maintenance facilities; to develop and apply a methodology for measuring the total productivity of a Floridian transit maintenance facility (Bradenton-Manatee County bus maintenance facility whichmore » has been introducing automation since 1983); and to develop a practical step-by-step implementation scheme for the total productivity-based productivity measurement system that any bus manager can use. All 3 objectives were successfully accomplished.« less
Pistón, Mariela; Silva, Javier; Pérez-Zambra, Ramiro; Dol, Isabel; Knochen, Moisés
2012-04-01
A multicommutated flow system was designed and evaluated for the determination of total arsenic and selenium by Hydride Generation Atomic Absorption Spectrometry (HG-AAS). It was applied to the determination of arsenic and selenium in samples of natural and drinking water. Detection limits were 0.46 and 0.08 μg l(-1) for arsenic and selenium, respectively; sampling frequency was 120 samples h(-1) for arsenic and 160 samples h(-1) for selenium. Linear ranges found were 1.54-10 μg l(-1) (R = 0.999) for arsenic and 0.27-27 μg l(-1) (R = 0.999) for selenium. Accuracy was evaluated by spiking various water samples and using a reference material. Recoveries were in the range 95-116%. Analytical precision (s ( r ) (%), n = 10) was 6% for both elements. Compared with the Standard Methods, APHA, 3114B manual method, the system consumes at least 10 times less sample per determination, and the quantities of acid and reducing agent used are significantly lower with a reduction in the generation of pollutants and waste. As an additional advantage, the system is very fast, efficient and environmentally friendly for monitoring total arsenic and selenium levels in waters.
Tee, Pei-Fang; Abdullah, Mohammad Omar; Tan, Ivy Ai Wei; Mohamed Amin, Mohamed Afizal; Nolasco-Hipolito, Cirilo; Bujang, Kopli
2016-09-01
An air-cathode MFC-adsorption hybrid system, made from earthen pot was designed and tested for simultaneous wastewater treatment and energy recovery. Such design had demonstrated superior characteristics of low internal resistance (29.3Ω) and favor to low-cost, efficient wastewater treatment and power generation (55mW/m(3)) with average current of 2.13±0.4mA. The performance between MFC-adsorption hybrid system was compared to the standalone adsorption system and results had demonstrated great pollutants removals of the integrated system especially for chemical oxygen demand (COD), biochemical oxygen demand (BOD3), total organic carbon (TOC), total volatile solids (TVS), ammoniacal nitrogen (NH3-N) and total nitrogen (TN) because such system combines the advantages of each individual unit. Besides the typical biological and electrochemical processes that happened in an MFC system, an additional physicochemical process from the activated carbon took place simultaneously in the MFC-adsorption hybrid system which would further improved on the wastewater quality. Copyright © 2016 Elsevier Ltd. All rights reserved.
Correlation of total, diffuse, and direct solar radiation
NASA Technical Reports Server (NTRS)
Buyco, E. H.; Namkoong, D.
1977-01-01
Present requirements for realistic solar energy system evaluations necessitate a comprehensive body of solar-radition data. The data should include both diffuse and direct solar radiation as well as their total on an hourly (or shorter) basis. In general, however, only the total solar radiation values were recorded. This report presents a correlation that relates the diffuse component of an hourly total solar radiation value to the total radiation ratio of the maximum value attainable. The data used were taken at the Blue Hill Observatory in Milton, Massachusetts, for the period 1952. The relation - in the form of the data plots - can be used in situations in which only the hourly total radiation data are available but the diffuse component is desired.
ERIC Educational Resources Information Center
Pennington, Kaitlin
2014-01-01
In 2011, President Barack Obama and Secretary of Education Arne Duncan provided states with an opportunity for flexibility from certain requirements under the Elementary and Secondary Education Act, or ESEA, currently known as the No Child Left Behind, or NCLB, Act. A total of 43 states; Washington, D.C.; Puerto Rico; and eight districts in…
Baik, Jong Sam; Jang, Seong Ho; Park, Dong Sik
2009-01-01
To develop an objective and scientific method to evaluate the brain injured and brain diseased persons with motor dysfunction, American Medical Association's Guides to the Evaluation of Permanent Impairment was used as an exemplar. After the motor dysfunction due to brain injury or brain disease was confirmed, active range of motion and muscle strength of affected extremities were measured. Also, the total function of extremities was evaluated through the assessment of activities of daily living, fine coordination of hand, balance and gait. Then, the total score of manual muscle test and functional assessment of impaired upper and lower extremity were added, respectively. Spasticity of upper and lower extremity was used as minus factors. Patients with movement disorder such as Parkinson's disease were assessed based on the degree of dysfunction in response to medication. We develop a new rating system based on the concept of total score. PMID:19503680
Evaluation of the Hitachi 717 analyser.
Biosca, C; Antoja, F; Sierra, C; Douezi, H; Macià, M; Alsina, M J; Galimany, R
1989-01-01
The selective multitest Boehringer Mannheim Hitachi 717 analyser was evaluated according to the guidelines of the Comisión de Instrumentación de la Sociedad Española de Química Clinica and the European Committee for Clinical Laboratory Standards. The evaluation was performed in two steps: examination of the analytical units and evaluation in routine operation.THE EVALUATION OF THE ANALYTICAL UNITS INCLUDED A PHOTOMETRIC STUDY: the inaccuracy is acceptable for 340 and 405 nm; the imprecision ranges from 0.12 to 0.95% at 340 nm and from 0.30 to 0.73 at 405 nm, the linearity shows some dispersion at low absorbance for NADH at 340 nm, the drift is negligible, the imprecision of the pipette delivery system increases when the sample pipette operates with 3 mul, the reagent pipette imprecision is acceptable and the temperature control system is good.UNDER ROUTINE WORKING CONDITIONS, SEVEN DETERMINATIONS WERE STUDIED: glucose, creatinine, iron, total protein, AST, ALP and calcium. The within-run imprecision (CV) ranged from 0.6% for total protein and AST to 6.9% for iron. The between run imprecision ranged from 2.4% for glucose to 9.7% for iron. Some contamination was found in the carry-over study. The relative inaccuracy is good for all the constituents assayed.
Al-Wakeel, Nadya; O h-Ici, Darach; Schmitt, Katharina R; Messroghli, Daniel R; Riesenkampff, Eugénie; Berger, Felix; Kuehne, Titus; Peters, Bjoern
2016-02-01
In patients with CHD, cardiac MRI is often indicated for functional and anatomical assessment. With the recent introduction of MRI-conditional pacemaker systems, cardiac MRI has become accessible for patients with pacemakers. The present clinical study aims to evaluate safety, susceptibility artefacts, and image reading of cardiac MRI in patients with CHD and MRI-conditional pacemaker systems. Material and methods CHD patients with MRI-conditional pacemaker systems and a clinical need for cardiac MRI were examined with a 1.5-T MRI system. Lead function was tested before and after MRI. Artefacts and image readings were evaluated using a four-point grading scale. A total of nine patients with CHD (mean age 34.0 years, range 19.5-53.6 years) received a total of 11 cardiac MRI examinations. Owing to clinical indications, seven patients had previously been converted from conventional to MRI-conditional pacemaker systems. All MRI examinations were completed without adverse effects. Device testing immediately after MRI and at follow-up showed no alteration of pacemaker device and lead function. Clinical questions could be addressed and answered in all patients. Cardiac MRI can be performed safely with high certainty of diagnosis in CHD patients with MRI-conditional pacemaker systems. In case of clinically indicated lead and box changing, CHD patients with non-MRI-conditional pacemaker systems should be considered for complete conversion to MRI-conditional systems.
Validity of a portable glucose, total cholesterol, and triglycerides multi-analyzer in adults.
Coqueiro, Raildo da Silva; Santos, Mateus Carmo; Neto, João de Souza Leal; Queiroz, Bruno Morbeck de; Brügger, Nelson Augusto Jardim; Barbosa, Aline Rodrigues
2014-07-01
This study investigated the accuracy and precision of the Accutrend Plus system to determine blood glucose, total cholesterol, and plasma triglycerides in adults and evaluated its efficiency in measuring these blood variables. The sample consisted of 53 subjects (≥ 18 years). For blood variable laboratory determination, venous blood samples were collected and processed in a Labmax 240 analyzer. To measure blood variables with the Accutrend Plus system, samples of capillary blood were collected. In the analysis, the following tests were included: Wilcoxon and Student's t-tests for paired samples, Lin's concordance coefficient, Bland-Altman method, receiver operating characteristic curve, McNemar test, and k statistics. The results show that the Accutrend Plus system provided significantly higher values (p ≤ .05) of glucose and triglycerides but not of total cholesterol (p > .05) as compared to the values determined in the laboratory. However, the system showed good reproducibility (Lin's coefficient: glucose = .958, triglycerides = .992, total cholesterol = .940) and high concordance with the laboratory method (Lin's coefficient: glucose = .952, triglycerides = .990, total cholesterol = .944) and high sensitivity (glucose = 80.0%, triglycerides = 90.5%, total cholesterol = 84.4%) and specificity (glucose = 100.0%, triglycerides = 96.9%, total cholesterol = 95.2%) in the discrimination of high values of the three blood variables analyzed. It could be concluded that despite the tendency to overestimate glucose and triglyceride levels, a portable multi-analyzer is a valid alternative for the monitoring of metabolic disorders and cardiovascular risk factors. © The Author(s) 2013.
Evaluating Carbonate System Algorithms in a Nearshore System: Does Total Alkalinity Matter?
Sweet, Julia; Brzezinski, Mark A.; McNair, Heather M.; Passow, Uta
2016-01-01
Ocean acidification is a threat to many marine organisms, especially those that use calcium carbonate to form their shells and skeletons. The ability to accurately measure the carbonate system is the first step in characterizing the drivers behind this threat. Due to logistical realities, regular carbonate system sampling is not possible in many nearshore ocean habitats, particularly in remote, difficult-to-access locations. The ability to autonomously measure the carbonate system in situ relieves many of the logistical challenges; however, it is not always possible to measure the two required carbonate parameters autonomously. Observed relationships between sea surface salinity and total alkalinity can frequently provide a second carbonate parameter thus allowing for the calculation of the entire carbonate system. Here, we assessed the rigor of estimating total alkalinity from salinity at a depth <15 m by routinely sampling water from a pier in southern California for several carbonate system parameters. Carbonate system parameters based on measured values were compared with those based on estimated TA values. Total alkalinity was not predictable from salinity or from a combination of salinity and temperature at this site. However, dissolved inorganic carbon and the calcium carbonate saturation state of these nearshore surface waters could both be estimated within on average 5% of measured values using measured pH and salinity-derived or regionally averaged total alkalinity. Thus we find that the autonomous measurement of pH and salinity can be used to monitor trends in coastal changes in DIC and saturation state and be a useful method for high-frequency, long-term monitoring of ocean acidification. PMID:27893739
Evaluating Carbonate System Algorithms in a Nearshore System: Does Total Alkalinity Matter?
Jones, Jonathan M; Sweet, Julia; Brzezinski, Mark A; McNair, Heather M; Passow, Uta
2016-01-01
Ocean acidification is a threat to many marine organisms, especially those that use calcium carbonate to form their shells and skeletons. The ability to accurately measure the carbonate system is the first step in characterizing the drivers behind this threat. Due to logistical realities, regular carbonate system sampling is not possible in many nearshore ocean habitats, particularly in remote, difficult-to-access locations. The ability to autonomously measure the carbonate system in situ relieves many of the logistical challenges; however, it is not always possible to measure the two required carbonate parameters autonomously. Observed relationships between sea surface salinity and total alkalinity can frequently provide a second carbonate parameter thus allowing for the calculation of the entire carbonate system. Here, we assessed the rigor of estimating total alkalinity from salinity at a depth <15 m by routinely sampling water from a pier in southern California for several carbonate system parameters. Carbonate system parameters based on measured values were compared with those based on estimated TA values. Total alkalinity was not predictable from salinity or from a combination of salinity and temperature at this site. However, dissolved inorganic carbon and the calcium carbonate saturation state of these nearshore surface waters could both be estimated within on average 5% of measured values using measured pH and salinity-derived or regionally averaged total alkalinity. Thus we find that the autonomous measurement of pH and salinity can be used to monitor trends in coastal changes in DIC and saturation state and be a useful method for high-frequency, long-term monitoring of ocean acidification.
Evaluating the Environmental Performance of the U.S. Next Generation Air Transportation System
NASA Technical Reports Server (NTRS)
Graham, Michael; Augustine, Stephen; Ermatinger, Christopher; Difelici, John; Thompson, Terence R.; Marcolini, Michael A.; Creedon, Jeremiah F.
2009-01-01
The environmental impacts of several possible U.S. Next Generation Air Transportation scenarios have been quantitatively evaluated for noise, air-quality, fuel-efficiency, and CO2 impacts. Three principal findings have emerged. (1) 2025 traffic levels about 30% higher than 2006 are obtained by increasing traffic according to FAA projections while also limiting traffic at each airport using reasonable ratios of demand to capacity. NextGen operational capabilities alone enable attainment of an additional 10-15% more flights beyond that 2025 baseline level with negligible additional noise, air-quality, and fuel-efficiency impacts. (2) The addition of advanced engine and airframe technologies provides substantial additional reductions in noise and air-quality impacts, and further improves fuel efficiency. 2025 environmental goals based on projected system-wide improvement rates of about 1% per year for noise and fuel-efficiency (an air-quality goal is not yet formulated) are achieved using this new vehicle technology. (3) Overall air-transport "product", as measured by total flown distance or total payload distance, increases by about 50% relative to 2006, but total fuel consumption and CO2 production increase by only about 40% using NextGen operational capabilities. With the addition of advanced engine/airframe technologies, the increase in total fuel consumption and CO2 production can be reduced to about 30%.
NASA Technical Reports Server (NTRS)
Witte, Jacquelyn C.; Thompson, Anne M.; Ziemke, Jerald R.; Wargan, Krzysztof
2014-01-01
The Ozone Mapping Profile Suite (OMPS) was launched October 28, 2011 on-board the Suomi NPP satellite (http://npp.gsfc.nasa.gov). OMPS is the next generation total column ozone mapping instrument for monitoring the global distribution of stratospheric ozone. OMPS includes a limb profiler to measure the vertical structure of stratosphere ozone down to the mid-troposphere. This study uses tropical ozonesonde profile measurements from the Southern Hemisphere Additional Ozonesondes (SHADOZ, http://croc.gsfc.nasa.gov/shadoz) archive to evaluate total column ozone retrievals from OMPS and concurrent measurements from the Aura Ozone Monitoring Instrument (OMI), the predecessor of OMPS with a data record going back to 2004. We include ten SHADOZ stations that contain data overlapping the OMPS time period (2012-2013). This study capitalizes on the ozone profile measurements from SHADOZ to evaluate OMPS limb profile retrievals. Finally, we use SHADOZ sondes and OMPS retrievals to examine the agreement with the GEOS-5 Ozone Assimilation System (GOAS). The GOAS uses data from the OMI and the Microwave Limb Sounder (MLS) to constrain the total column and stratospheric profiles of ozone. The most recent version of the assimilation system is well constrained to the total column compared with SHADOZ ozonesonde data.
NASA Technical Reports Server (NTRS)
Smathers, J. B.; Kuykendall, W. E., Jr.; Wright, R. E., Jr.; Marshall, J. R.
1973-01-01
Radioisotope measurement techniques and neutron activation analysis are evaluated for use in identifying and locating contamination sources in space environment simulation chambers. The alpha range method allows the determination of total contaminant concentration in vapor state and condensate state. A Cf-252 neutron activation analysis system for detecting oils and greases tagged with stable elements is described. While neutron activation analysis of tagged contaminants offers specificity, an on-site system is extremely costly to implement and provides only marginal detection sensitivity under even the most favorable conditions.
Teksheva, L M; Zvezdina, I V
2014-01-01
Hygienic evaluation of innovative equipment in educational institutions requires the use of appropriate methods permitting to establish valuable criterias for the effectiveness of the application of new technologies. The study of the response of the cardiovascular system of schoolchildren under using different light sources allowed to establish the increase in adaptive capacities and the improvement of the functional state of the organism in LED in comparison with fluorescent lighting.
Spears, D Ross; McNeil, Carrie; Warnock, Eli; Trapp, Jonathan; Oyinloye, Oluremi; Whitehurst, Vanessa; Decker, K C; Chapman, Sandy; Campbell, Morris; Meechan, Paul
2014-06-01
This study evaluates the predictability in temporal absences trends due to all causes (total absenteeism) among employees at a federal agency. The objective is to determine how leave trends vary within the year, and determine whether trends are predictable. Ten years of absenteeism data from an attendance system were analyzed for rates of total absence. Trends over a 10-year period followed predictable and regular patterns during a given year that correspond to major holiday periods. Temporal trends in leave among small, medium, and large facilities compared favorably with the agency as a whole. Temporal trends in total absenteeism rates for an organization can be determined using its attendance system. The ability to predict employee absenteeism rates can be extremely helpful for management in optimizing business performance and ensuring that an organization meets its mission.
ERIC Educational Resources Information Center
Su, Chung-Ho; Cheng, Ching-Hsue
2016-01-01
This study aims to explore the factors in a patient's rehabilitation achievement after a total knee replacement (TKR) patient exercises, using a PCA-ANFIS emotion model-based game rehabilitation system, which combines virtual reality (VR) and motion capture technology. The researchers combine a principal component analysis (PCA) and an adaptive…
Total Internal Reflection Microscopy (TIRM) as a nondestructive surface damage assessment tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liao, Z.M.; Cohen, S.J.; Taylor, J.R.
1994-10-01
An easy to use, nondestructive, method for evaluating subsurface damage in polished substrates has been established at LLNL. Subsurface damage has been related to laser damage in coated optical components used in high power, high repetition rate laser systems. Total Internal Reflection Microscopy (TIRM) has been shown to be a viable nondestructive technique in analyzing subsurface damage in optical components. A successful TIRM system has been established for evaluating subsurface damage on fused silica components. Laser light scattering from subsurface damage sites is collected through a Nomarski microscope. These images are then captured by a CCD camera for analysis onmore » a computer. A variety of optics, including components with intentional subsurface damage due to grinding and polishing, have been analyzed and their TIRM images compared to an existing destructive etching method. Methods for quantitative measurement of subsurface damage are also discussed.« less
NASA Technical Reports Server (NTRS)
Meyer, G.; Cicolani, L.
1981-01-01
A practical method for the design of automatic flight control systems for aircraft with complex characteristics and operational requirements, such as the powered lift STOL and V/STOL configurations, is presented. The method is effective for a large class of dynamic systems requiring multi-axis control which have highly coupled nonlinearities, redundant controls, and complex multidimensional operational envelopes. It exploits the concept of inverse dynamic systems, and an algorithm for the construction of inverse is given. A hierarchic structure for the total control logic with inverses is presented. The method is illustrated with an application to the Augmentor Wing Jet STOL Research Aircraft equipped with a digital flight control system. Results of flight evaluation of the control concept on this aircraft are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powell, Danny H; Elwood Jr, Robert H
2011-01-01
An effective risk assessment system is needed to address the threat posed by an active or passive insider who, acting alone or in collusion, could attempt diversion or theft of nuclear material. The material control and accountability (MC&A) system effectiveness tool (MSET) is a self-assessment or inspection tool utilizing probabilistic risk assessment (PRA) methodology to calculate the system effectiveness of a nuclear facility's material protection, control, and accountability (MPC&A) system. The MSET process is divided into four distinct and separate parts: (1) Completion of the questionnaire that assembles information about the operations of every aspect of the MPC&A system; (2)more » Conversion of questionnaire data into numeric values associated with risk; (3) Analysis of the numeric data utilizing the MPC&A fault tree and the SAPHIRE computer software; and (4) Self-assessment using the MSET reports to perform the effectiveness evaluation of the facility's MPC&A system. The process should lead to confirmation that mitigating features of the system effectively minimize the threat, or it could lead to the conclusion that system improvements or upgrades are necessary to achieve acceptable protection against the threat. If the need for system improvements or upgrades is indicated when the system is analyzed, MSET provides the capability to evaluate potential or actual system improvements or upgrades. A facility's MC&A system can be evaluated at a point in time. The system can be reevaluated after upgrades are implemented or after other system changes occur. The total system or specific subareas within the system can be evaluated. Areas of potential system improvement can be assessed to determine where the most beneficial and cost-effective improvements should be made. Analyses of risk importance factors show that sustainability is essential for optimal performance and reveals where performance degradation has the greatest impact on total system risk. The risk importance factors show the amount of risk reduction achievable with potential upgrades and the amount of risk reduction achieved after upgrades are completed. Applying the risk assessment tool gives support to budget prioritization by showing where budget support levels must be sustained for MC&A functions most important to risk. Results of the risk assessment are also useful in supporting funding justifications for system improvements that significantly reduce system risk. The functional model, the system risk assessment tool, and the facility evaluation questionnaire are valuable educational tools for MPC&A personnel. These educational tools provide a framework for ongoing dialogue between organizations regarding the design, development, implementation, operation, assessment, and sustainability of MPC&A systems. An organization considering the use of MSET as an analytical tool for evaluating the effectiveness of its MPC&A system will benefit from conducting a complete MSET exercise at an existing nuclear facility.« less
Lombarts, Kiki M J M H; Ferguson, Andrew; Hollmann, Markus W; Malling, Bente; Arah, Onyebuchi A
2016-11-01
Given the increasing international recognition of clinical teaching as a competency and regulation of residency training, evaluation of anesthesiology faculty teaching is needed. The System for Evaluating Teaching Qualities (SETQ) Smart questionnaires were developed for assessing teaching performance of faculty in residency training programs in different countries. This study investigated (1) the structure, (2) the psychometric qualities of the new tools, and (3) the number of residents' evaluations needed per anesthesiology faculty to use the instruments reliably. Two SETQ Smart questionnaires-for faculty self-evaluation and for resident evaluation of faculty-were developed. A multicenter survey was conducted among 399 anesthesiology faculty and 430 residents in six countries. Statistical analyses included exploratory factor analysis, reliability analysis using Cronbach α, item-total scale correlations, interscale correlations, comparison of composite scales to global ratings, and generalizability analysis to assess residents' evaluations needed per faculty. In total, 240 residents completed 1,622 evaluations of 247 faculty. The SETQ Smart questionnaires revealed six teaching qualities consisting of 25 items. Cronbach α's were very high (greater than 0.95) for the overall SETQ Smart questionnaires and high (greater than 0.80) for the separate teaching qualities. Interscale correlations were all within the acceptable range of moderate correlation. Overall, questionnaire and scale scores correlated moderately to highly with the global ratings. For reliable feedback to individual faculty, three to five resident evaluations are needed. The first internationally piloted questionnaires for evaluating individual anesthesiology faculty teaching performance can be reliably, validly, and feasibly used for formative purposes in residency training.
Lee, Seonah
2013-10-01
This study aimed to organize the system features of decision support technologies targeted at nursing practice into assessment, problem identification, care plans, implementation, and outcome evaluation. It also aimed to identify the range of the five stage-related sequential decision supports that computerized clinical decision support systems provided. MEDLINE, CINAHL, and EMBASE were searched. A total of 27 studies were reviewed. The system features collected represented the characteristics of each category from patient assessment to outcome evaluation. Several features were common across the reviewed systems. For the sequential decision support, all of the reviewed systems provided decision support in sequence for patient assessment and care plans. Fewer than half of the systems included problem identification. There were only three systems operating in an implementation stage and four systems in outcome evaluation. Consequently, the key steps for sequential decision support functions were initial patient assessment, problem identification, care plan, and outcome evaluation. Providing decision support in such a full scope will effectively help nurses' clinical decision making. By organizing the system features, a comprehensive picture of nursing practice-oriented computerized decision support systems was obtained; however, the development of a guideline for better systems should go beyond the scope of a literature review.
Evaluation of a new ostomy mouldable seal: an international product evaluation.
Tielemans, Chantal; Probert, Rosalind; Forest-Lalande, Louise; Hansen, Anne Steen; Aggerholm, Søren; Ajslev, Teresa Adeltoft
2016-12-08
A new mouldable seal, Brava® Protective Seal, was evaluated by patients on aspects related to residue, durability, and preference. A total of 135 patients from four countries participated (Denmark, Germany, Japan and the USA) and the new product was compared to the patients' usual pouching systems. Less residue and easier skin cleansing was observed, which may benefit patient quality of life. The possible benefits of less residue for peristomal skin health need further investigation.
Biondo, Patricia D; Lee, Lydia D; Davison, Sara N; Simon, Jessica E
2016-09-01
Advance care planning initiatives are being implemented across healthcare systems around the world, but how best to evaluate their implementation is unknown. To identify gaps and/or redundancies in current evaluative strategies to help healthcare systems develop future evaluative frameworks for ACP. Systematic review. Peer-reviewed and gray literature searches were conducted till February 2015 to answer: "What methods have healthcare systems used to evaluate implementation of advance care planning initiatives?" A PICOS framework was developed to identify articles describing the implementation and evaluation of a health system-level advance care planning initiative. Outcome measures were mapped onto a conceptual quality indicator framework based on the Institute of Medicine and Donabedian models of healthcare quality. A total of 46 studies met inclusion criteria for analysis. Most articles reported on single parts of a healthcare system (e.g. continuing care). The most common outcome measures pertained to document completion, followed by healthcare resource use. Patient-, family-, or healthcare provider-reported outcomes were less commonly measured. Concordance measures (e.g. dying in place of choice) were reported by only 26% of studies. The conceptual quality indicator framework identified gaps and redundancies in measurement and is presented as a potential foundation from which to develop a comprehensive advance care planning evaluation framework. Document completion is frequently used to evaluate advance care planning program implementation; capturing the quality of care appears to be more difficult. This systematic review provides health system administrators with a comprehensive summary of measures used to evaluate advance care planning and may identify gaps in evaluation within their local context. © The Author(s) 2016.
Whitehead, Paul; Bussi, Gianbattista; Hossain, Mohammed Abed; Dolk, Michaela; Das, Partho; Comber, Sean; Peters, Rebecca; Charles, Katrina J; Hope, Rob; Hossain, Md Sarwar
2018-08-01
River water quality in rapidly urbanising Asian cities threatens to damage the resource base on which human health, economic growth and poverty reduction all depend. Dhaka reflects the challenges and opportunities for balancing these dynamic and complex trade-offs which goals can be achieved through effective policy interventions. There is a serious problem of water pollution in central Dhaka, in the Turag-Tongi-Balu River system in Bangladesh with the river system being one of the most polluted in the world at the moment. A baseline survey of water chemistry and total coliforms has been undertaken and shows dissolved oxygen close to zero in the dry season, high organic loading together with extreme levels of Ammonium-N and total coliform in the water. Models have been applied to assess hydrochemical processes in the river and evaluate alternative strategies for policy and the management of the pollution issues. In particular models of flow, Nitrate-N, Ammonium-N and indicator bacteria (total coliforms) are applied to simulate water quality in the river system. Various scenarios are explored to clean up the river system, including flow augmentation and improved effluent treatment. The model results indicate that improved effluent treatment is likely to have a more significant impact on reducing Ammonium-N and total coliforms than flow augmentation, but a combined strategy would greatly reduce the pollution problems in the Turag-Tongi-Balu River System. Copyright © 2018. Published by Elsevier B.V.
Methods for semi-automated indexing for high precision information retrieval
NASA Technical Reports Server (NTRS)
Berrios, Daniel C.; Cucina, Russell J.; Fagan, Lawrence M.
2002-01-01
OBJECTIVE: To evaluate a new system, ISAID (Internet-based Semi-automated Indexing of Documents), and to generate textbook indexes that are more detailed and more useful to readers. DESIGN: Pilot evaluation: simple, nonrandomized trial comparing ISAID with manual indexing methods. Methods evaluation: randomized, cross-over trial comparing three versions of ISAID and usability survey. PARTICIPANTS: Pilot evaluation: two physicians. Methods evaluation: twelve physicians, each of whom used three different versions of the system for a total of 36 indexing sessions. MEASUREMENTS: Total index term tuples generated per document per minute (TPM), with and without adjustment for concordance with other subjects; inter-indexer consistency; ratings of the usability of the ISAID indexing system. RESULTS: Compared with manual methods, ISAID decreased indexing times greatly. Using three versions of ISAID, inter-indexer consistency ranged from 15% to 65% with a mean of 41%, 31%, and 40% for each of three documents. Subjects using the full version of ISAID were faster (average TPM: 5.6) and had higher rates of concordant index generation. There were substantial learning effects, despite our use of a training/run-in phase. Subjects using the full version of ISAID were much faster by the third indexing session (average TPM: 9.1). There was a statistically significant increase in three-subject concordant indexing rate using the full version of ISAID during the second indexing session (p < 0.05). SUMMARY: Users of the ISAID indexing system create complex, precise, and accurate indexing for full-text documents much faster than users of manual methods. Furthermore, the natural language processing methods that ISAID uses to suggest indexes contributes substantially to increased indexing speed and accuracy.
Methods for Semi-automated Indexing for High Precision Information Retrieval
Berrios, Daniel C.; Cucina, Russell J.; Fagan, Lawrence M.
2002-01-01
Objective. To evaluate a new system, ISAID (Internet-based Semi-automated Indexing of Documents), and to generate textbook indexes that are more detailed and more useful to readers. Design. Pilot evaluation: simple, nonrandomized trial comparing ISAID with manual indexing methods. Methods evaluation: randomized, cross-over trial comparing three versions of ISAID and usability survey. Participants. Pilot evaluation: two physicians. Methods evaluation: twelve physicians, each of whom used three different versions of the system for a total of 36 indexing sessions. Measurements. Total index term tuples generated per document per minute (TPM), with and without adjustment for concordance with other subjects; inter-indexer consistency; ratings of the usability of the ISAID indexing system. Results. Compared with manual methods, ISAID decreased indexing times greatly. Using three versions of ISAID, inter-indexer consistency ranged from 15% to 65% with a mean of 41%, 31%, and 40% for each of three documents. Subjects using the full version of ISAID were faster (average TPM: 5.6) and had higher rates of concordant index generation. There were substantial learning effects, despite our use of a training/run-in phase. Subjects using the full version of ISAID were much faster by the third indexing session (average TPM: 9.1). There was a statistically significant increase in three-subject concordant indexing rate using the full version of ISAID during the second indexing session (p < 0.05). Summary. Users of the ISAID indexing system create complex, precise, and accurate indexing for full-text documents much faster than users of manual methods. Furthermore, the natural language processing methods that ISAID uses to suggest indexes contributes substantially to increased indexing speed and accuracy. PMID:12386114
Economic analysis of the design and fabrication of a space qualified power system
NASA Technical Reports Server (NTRS)
Ruselowski, G.
1980-01-01
An economic analysis was performed to determine the cost of the design and fabrication of a low Earth orbit, 2 kW photovoltaic/battery, space qualified power system. A commercially available computer program called PRICE (programmed review of information for costing and evaluation) was used to conduct the analysis. The sensitivity of the various cost factors to the assumptions used is discussed. Total cost of the power system was found to be $2.46 million with the solar array accounting for 70.5%. Using the assumption that the prototype becomes the flight system, 77.3% of the total cost is associated with manufacturing. Results will be used to establish whether the cost of space qualified hardware can be reduced by the incorporation of commercial design, fabrication, and quality assurance methods.
Are university rankings useful to improve research? A systematic review.
Vernon, Marlo M; Balas, E Andrew; Momani, Shaher
2018-01-01
Concerns about reproducibility and impact of research urge improvement initiatives. Current university ranking systems evaluate and compare universities on measures of academic and research performance. Although often useful for marketing purposes, the value of ranking systems when examining quality and outcomes is unclear. The purpose of this study was to evaluate usefulness of ranking systems and identify opportunities to support research quality and performance improvement. A systematic review of university ranking systems was conducted to investigate research performance and academic quality measures. Eligibility requirements included: inclusion of at least 100 doctoral granting institutions, be currently produced on an ongoing basis and include both global and US universities, publish rank calculation methodology in English and independently calculate ranks. Ranking systems must also include some measures of research outcomes. Indicators were abstracted and contrasted with basic quality improvement requirements. Exploration of aggregation methods, validity of research and academic quality indicators, and suitability for quality improvement within ranking systems were also conducted. A total of 24 ranking systems were identified and 13 eligible ranking systems were evaluated. Six of the 13 rankings are 100% focused on research performance. For those reporting weighting, 76% of the total ranks are attributed to research indicators, with 24% attributed to academic or teaching quality. Seven systems rely on reputation surveys and/or faculty and alumni awards. Rankings influence academic choice yet research performance measures are the most weighted indicators. There are no generally accepted academic quality indicators in ranking systems. No single ranking system provides a comprehensive evaluation of research and academic quality. Utilizing a combined approach of the Leiden, Thomson Reuters Most Innovative Universities, and the SCImago ranking systems may provide institutions with a more effective feedback for research improvement. Rankings which extensively rely on subjective reputation and "luxury" indicators, such as award winning faculty or alumni who are high ranking executives, are not well suited for academic or research performance improvement initiatives. Future efforts should better explore measurement of the university research performance through comprehensive and standardized indicators. This paper could serve as a general literature citation when one or more of university ranking systems are used in efforts to improve academic prominence and research performance.
Sensing systems efficiency evaluation and comparison for homeland security and homeland defense
NASA Astrophysics Data System (ADS)
Pakhomov, Alexander A.
2010-04-01
Designers and consumers of various security, intelligence, surveillance and reconnaissance (ISR) systems as well as various unattended ground sensors pay most attention to their commonly used performance characteristics such as probability of a target detection and probability of a false alarm. These characteristics are used for systems comparison and evaluation. However, it is not enough for end-users of these systems as well as for their total/final effectiveness assessment. This article presents and discusses a system approach to an efficiency estimation of the security and ISR systems. Presented approach aims at final result of the system's function and use. It allows setting up reasonable technical and structural requirements for the security and ISR systems, to make trustworthy comparison and practical application planning of such systems. It also allows finding forward-looking, perspective ways of systems development. Presented results can be guidance to both designers and consumers.
Dennis, Cara; Karim, Faris; Smith, J Scott
2015-02-01
Heterocyclic amines (HCAs), highly mutagenic and potentially carcinogenic by-products, form during Maillard browning reactions, specifically in muscle-rich foods. Chemical model systems allow examination of in vitro formation of HCAs while eliminating complex matrices of meat. Limited research has evaluated the effects of Maillard reaction parameters on HCA formation. Therefore, 4 essential Maillard variables (precursors molar concentrations, water amount, sugar type, and sugar amounts) were evaluated to optimize a model system for the study of 4 HCAs: 2-amino-3-methylimidazo-[4,5-f]quinoline, 2-amino-3-methylimidazo[4,5-f]quinoxaline, 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline, and 2-amino-3,4,8-trimethyl-imidazo[4,5-f]quinoxaline. Model systems were dissolved in diethylene glycol, heated at 175 °C for 40 min, and separated using reversed-phase liquid chromatography. To define the model system, precursor amounts (threonine and creatinine) were adjusted in molar increments (0.2/0.2, 0.4/0.4, 0.6/0.6, and 0.8/0.8 mmol) and water amounts by percentage (0%, 5%, 10%, and 15%). Sugars (lactose, glucose, galactose, and fructose) were evaluated in several molar amounts proportional to threonine and creatinine (quarter, half, equi, and double). The precursor levels and amounts of sugar were significantly different (P < 0.05) in regards to total HCA formation, with 0.6/0.6/1.2 mmol producing higher levels. Water concentration and sugar type also had a significant effect (P < 0.05), with 5% water and lactose producing higher total HCA amounts. A model system containing threonine (0.6 mmol), creatinine (0.6 mmol), and glucose (1.2 mmol), with 15% water was determined to be the optimal model system with glucose and 15% water being a better representation of meat systems. © 2015 Institute of Food Technologists®
Iglesias-Parra, Maria Rosa; García-Guerrero, Alfonso; García-Mayor, Silvia; Kaknani-Uttumchandani, Shakira; León-Campos, Álvaro; Morales-Asencio, José Miguel
2015-07-01
To develop an evaluation system of clinical competencies for the practicum of nursing students based on the Nursing Interventions Classification (NIC). Psychometric validation study: the first two phases addressed definition and content validation, and the third phase consisted of a cross-sectional study for analyzing reliability. The study population was undergraduate nursing students and clinical tutors. Through the Delphi technique, 26 competencies and 91 interventions were isolated. Cronbach's α was 0.96. Factor analysis yielded 18 factors that explained 68.82% of the variance. Overall inter-item correlation was 0.26, and total-item correlation ranged between 0.66 and 0.19. A competency system for the nursing practicum, structured on the NIC, is a reliable method for assessing and evaluating clinical competencies. Further evaluations in other contexts are needed. The availability of standardized language systems in the nursing discipline supposes an ideal framework to develop the nursing curricula. © 2015 Sigma Theta Tau International.
Performance evaluation of a second-generation elastic loop mobility system
NASA Technical Reports Server (NTRS)
Melzer, K. J.; Swanson, G. D.
1974-01-01
Tests were conducted to evaluate the mobility performance of a second-generation Elastic Loop Mobility System (ELMS II). Performance on level test lanes and slopes of lunar soil simulant (LSS) and obstacle-surmounting and crevasse-crossing capabilities were investigated. In addition, internal losses and contact pressure distributions were evaluated. To evaluate the soft-soil performance, two basic soil conditions were tested: loose (LSS1) and dense (LSS5). These conditions embrace the spectrum of soil strengths tested during recent studies for NASA related to the mobility performance of the LRV. Data indicated that for the tested range of the various performance parameters, performance was independent of unit load (contact pressure) and ELMS II drum angular velocity, but was influenced by soil strength and ELMS pitch mode. Power requirements were smaller at a given system output for dense soil than for loose soil. The total system output in terms of pull developed or slope-climbing capability was larger for the ELMS II operating in restrained-pitch mode than in free-pitch mode.
Development of COTS ADC SEE Test System for the ATLAS LArCalorimeter Upgrade
Hu, Xue -Ye; Chen, Hu -Cheng; Chen, Kai; ...
2014-12-01
Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requirements of the FE electronics. Another interesting feature of ADS5272more » is its 6.5 clock cycles latency, which is the shortest among the 17 candidates. Based on the TID performance, we have designed a SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evaluating ADS5272 SEE characteristics in multiple irradiation tests. According to TID and SEE test results, ADS5272 was chosen to be implemented in the full-size LAr Trigger Digitizer Board (LTDB) demonstrator, which will be installed on ATLAS calorimeter during the 2014 Long Shutdown 1 (LS1).« less
Cost-benefit analysis of biopsy methods for suspicious mammographic lesions; discussion 994-5.
Fahy, B N; Bold, R J; Schneider, P D; Khatri, V; Goodnight, J E
2001-09-01
Stereotactic core biopsy (SCB) is more cost-effective than needle-localized biopsy (NLB) for evaluation and treatment of mammographic lesions. A computer-generated mathematical model was developed based on clinical outcome modeling to estimate costs accrued during evaluation and treatment of suspicious mammographic lesions. Total costs were determined for evaluation and subsequent treatment of cancer when either SCB or NLB was used as the initial biopsy method. Cost was estimated by the cumulative work relative value units accrued. The risk of malignancy based on the Breast Imaging Reporting Data System (BIRADS) score and mammographic suspicion of ductal carcinoma in situ were varied to simulate common clinical scenarios. Total cost accumulated during evaluation and subsequent surgical therapy (if required). Evaluation of BIRADS 5 lesions (highly suggestive, risk of malignancy = 90%) resulted in equivalent relative value units for both techniques (SCB, 15.54; NLB, 15.47). Evaluation of lesions highly suspicious for ductal carcinoma in situ yielded similar total treatment relative value units (SCB, 11.49; NLB, 10.17). Only for evaluation of BIRADS 4 lesions (suspicious abnormality, risk of malignancy = 34%) was SCB more cost-effective than NLB (SCB, 7.65 vs. NLB, 15.66). No difference in cost-benefit was found when lesions highly suggestive of malignancy (BIRADS 5) or those suspicious for ductal carcinoma in situ were evaluated initially with SCB vs. NLB, thereby disproving the hypothesis. Only for intermediate-risk lesions (BIRADS 4) did initial evaluation with SCB yield a greater cost savings than with NLB.
NASA Technical Reports Server (NTRS)
Stow, W. K.; Cheeseman, C.; Dallam, W.; Dietrich, D.; Dorfman, G.; Fleming, R.; Fries, R.; Guard, W.; Jackson, F.; Jankowski, H.
1975-01-01
Economic benefits studies regarding the application of remote sensing to resource management and the Total Earth Resources for the Shuttle Era (TERSSE) study to outline the structure and development of future systems are used, along with experience from LANDSAT and LACIE, to define the system performance and economics of an operational Earth Resources system. The system is to be based on current (LANDSAT follow-on) technology and its application to high priority resource management missions, such as global crop inventory. The TERSSE Operational System Study (TOSS) investigated system-level design alternatives using economic performance as the evaluation criterion. As such, the TOSS effort represented a significant step forward in the systems engineering and economic analysis of Earth Resources programs. By parametrically relating engineering design parameters, such as sensor performance details, to the economic benefit mechanisms a new level of confidence in the conclusions concerning the implementation of such systems can be reached.
Viancelli, A; Kunz, A; Steinmetz, R L R; Kich, J D; Souza, C K; Canal, C W; Coldebella, A; Esteves, P A; Barardi, C R M
2013-01-01
Swine effluents must be correctly handled to avoid negative environmental impacts. In this study, the profiles of two swine manure treatment systems were evaluated: a solid-liquid separation step, followed by an anaerobic reactor, and an aerobic step (System 1); and a biodigester followed by serial lagoons (System 2). Both systems were described by the assessment of chemical, bacterial and viral parameters. The results showed that in System 1, there was reduction of chemicals (COD, phosphorus, total Kjeldhal nitrogen - TKN - and NH(3)), total coliforms and Escherichia coli; however, the same reduction was not observed for Salmonella sp. Viral particles were significantly reduced but not totally eliminated from the effluent. In System 2, there was a reduction of chemicals, bacteria and viruses with no detection of Salmonella sp., circovirus, parvovirus, and torque teno virus in the effluent. The chemical results indicate that the treated effluent can be reused for cleaning swine facilities. However, the microbiological results show a need of additional treatment to achieve a complete inactivation for cases when direct contact with animals is required. Copyright © 2012 Elsevier Ltd. All rights reserved.
Kobayashi, Sow Alfred; Jamshidi, Ramin; O'Sullivan, Patricia; Palmer, Barnard; Hirose, Shinjiro; Stewart, Lygia; Kim, Edward Hyung
2011-01-01
The purpose of this work was to develop a more flexible system of laparoscopic surgery training with demonstrated effectiveness and construct validity. A personal, portable, durable laparoscopic trainer can be designed at low cost. The evaluation of expert surgeons on this device will reveal technical superiority over novices. With practice, novice surgeons can improve their performance significantly as measured by scores derived from performing skills with this training device. Prospective trial with observation and intervention components. The first aspect was observational comparison of novice and expert performance. The second was a prospective static-group comparison with pretest/posttest single-sample design. Tertiary-care academic medical center with affiliated general surgery residency. A total of 21 junior surgical residents and 5 experienced operators. Performance was assessed by the 5 tasks in the McGill Inanimate System for Training and Evaluation of Laparoscopic Skills (MISTELS): pegboard transfer, pattern cutting, placement of ligating loop, extracorporeal knotting, and intracorporeal knotting. Each task was assessed for accuracy and speed. Expert surgeons scored significantly higher than novices on total score and 4 of the 5 MISTELS tasks (peg transfer, pattern cut, extracorporeal knot, and intracorporeal knot). After 4 months of home-based training, the novices improved in total score and 3 of the 5 tasks (peg transfer, pattern cut, and extracorporeal knot). A low-cost personal laparoscopic training device can be built by individual residents. With their use, residents can significantly improve performance in important surgical skills. Evaluation of the system supports its validity. Copyright © 2011 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Implementation of a Sustainable Training System for Emergency in Vietnam.
Kang, Sunjoo; Seo, Hyejin; Ho, Binh Duy; Nguyen, Phuong Thi Anh
2018-01-01
This study analyzed the project outcomes to share lessons regarding the development of an emergency medicine education system in Vietnam. Retrospective evaluation was implemented using project outcome indicators. A total of 13 training courses were administered, with the collaboration of international experts in Korea and Vietnam. A total of 23 kinds of emergency medicine education equipment were purchased, and a basic life support (BLS) and two advanced cardiac life support labs were remodeled to provide appropriate simulation training. Throughout the 2 years of the project, nine Vietnamese BLS instructors were approved by the Korea Association of Cardiopulmonary Resuscitation under American Heart Association. Results of evaluation by Korean international development experts were based on five criteria, provided by the Development Assistance Committee of the Organization for Economic Co-operation and Development, were excellent. Success factors were identified as partnership, ownership, commitment, government support, and global networking. Project indicators were all accomplished and received an excellent evaluation by external experts. For sustainable success, healthcare policy and legal regulation to promote high quality and safe service to the Vietnamese people are recommended.
Solar-energy-system performance evaluation, October 1980-August 1981
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wetzel, P.E.
The solar site is an Animal Quarantine Center in Upton, New York, using 2484 ft/sup 2/ of flat-plate collectors and 5300 gallons of solar hot water storage located outside and above ground. The system was designed to provide 20% of the annual heating load and 100% of the annual domestic hot water load. The solar system actually provided 5% of the total system load. Many control and mechanical malfunctions contributed to the poor performance. (MHR)
[Results of training in the electronic health records in a tertiary care hospital].
Alva Espinosa, Carlos; Fuentes Domínguez, Marco Antonio; Garibay Huarte, Tania
2014-12-01
To assess the user evaluation of the electronic health records system together with its training program and to investigate the relation between the number of training sessions and the corresponding evaluation scores given by the participants. An anonymous survey was conducted between the medical, nursing and social worker personnel. The survey included seven multiple-choice questions with a numerical scale from 1 to 10 and an additional open question. IBM SPSS Statistics v18 software was used to perform ANOVA variance analysis. In total, 340 workers participated in this study; 317 were included in the statistical analysis, out of which 76% had one or two training sessions, 13.9% received three or more sessions and 10% had no training. The mean global training evaluation by the participants was 5.9 ± 2.3, median 6.3, while the electronic records system evaluation was 5.2 ± 2.3, median 5.5. In relation to the training and electronic records system it was observed that higher evaluation scores were obtained with increasing number of training sessions (p < 0.001). On the electronic records systems, personnel with no training evaluated the system with a mean score of 3.9 ± 2.7, while those who received three or more training sessions evaluated the system with a mean score of 6.1 ± 1.8 (p < 0.001).
Pe’eri, Shachak; Thein, May-Win; Rzhanov, Yuri; Celikkol, Barbaros; Swift, M. Robinson
2017-01-01
This paper presents a proof-of-concept optical detector array sensor system to be used in Unmanned Underwater Vehicle (UUV) navigation. The performance of the developed optical detector array was evaluated for its capability to estimate the position, orientation and forward velocity of UUVs with respect to a light source fixed in underwater. The evaluations were conducted through Monte Carlo simulations and empirical tests under a variety of motion configurations. Monte Carlo simulations also evaluated the system total propagated uncertainty (TPU) by taking into account variations in the water column turbidity, temperature and hardware noise that may degrade the system performance. Empirical tests were conducted to estimate UUV position and velocity during its navigation to a light beacon. Monte Carlo simulation and empirical results support the use of the detector array system for optics based position feedback for UUV positioning applications. PMID:28758936
User Interface Problems of a Nationwide Inpatient Information System: A Heuristic Evaluation.
Atashi, Alireza; Khajouei, Reza; Azizi, Amirabbas; Dadashi, Ali
2016-01-01
While studies have shown that usability evaluation could uncover many design problems of health information systems, the usability of health information systems in developing countries using their native language is poorly studied. The objective of this study was to evaluate the usability of a nationwide inpatient information system used in many academic hospitals in Iran. Three trained usability evaluators independently evaluated the system using Nielsen's 10 usability heuristics. The evaluators combined identified problems in a single list and independently rated the severity of the problems. We statistically compared the number and severity of problems identified by HIS experienced and non-experienced evaluators. A total of 158 usability problems were identified. After removing duplications 99 unique problems were left. The highest mismatch with usability principles was related to "Consistency and standards" heuristic (25%) and the lowest related to "Flexibility and efficiency of use" (4%). The average severity of problems ranged from 2.4 (Major problem) to 3.3 (Catastrophe problem). The experienced evaluator with HIS identified significantly more problems and gave higher severities to problems (p<0.02). Heuristic Evaluation identified a high number of usability problems in a widely used inpatient information system in many academic hospitals. These problems, if remain unsolved, may waste users' and patients' time, increase errors and finally threaten patient's safety. Many of them can be fixed with simple redesign solutions such as using clear labels and better layouts. This study suggests conducting further studies to confirm the findings concerning effect of evaluator experience on the results of Heuristic Evaluation.
User Interface Problems of a Nationwide Inpatient Information System: A Heuristic Evaluation
Atashi, Alireza; Azizi, Amirabbas; Dadashi, Ali
2016-01-01
Summary Introduction While studies have shown that usability evaluation could uncover many design problems of health information systems, the usability of health information systems in developing countries using their native language is poorly studied. The objective of this study was to evaluate the usability of a nationwide inpatient information system used in many academic hospitals in Iran. Material and Methods Three trained usability evaluators independently evaluated the system using Nielsen’s 10 usability heuristics. The evaluators combined identified problems in a single list and independently rated the severity of the problems. We statistically compared the number and severity of problems identified by HIS experienced and non-experienced evaluators. Results A total of 158 usability problems were identified. After removing duplications 99 unique problems were left. The highest mismatch with usability principles was related to “Consistency and standards” heuristic (25%) and the lowest related to “Flexibility and efficiency of use” (4%). The average severity of problems ranged from 2.4 (Major problem) to 3.3 (Catastrophe problem). The experienced evaluator with HIS identified significantly more problems and gave higher severities to problems (p<0.02). Discussion Heuristic Evaluation identified a high number of usability problems in a widely used inpatient information system in many academic hospitals. These problems, if remain unsolved, may waste users’ and patients’ time, increase errors and finally threaten patient’s safety. Many of them can be fixed with simple redesign solutions such as using clear labels and better layouts. This study suggests conducting further studies to confirm the findings concerning effect of evaluator experience on the results of Heuristic Evaluation. PMID:27081409
O'Brien, D; Shalloo, L; Patton, J; Buckley, F; Grainger, C; Wallace, M
2012-09-01
Life cycle assessment (LCA) and the Intergovernmental Panel on Climate Change (IPCC) guideline methodology, which are the principal greenhouse gas (GHG) quantification methods, were evaluated in this study using a dairy farm GHG model. The model was applied to estimate GHG emissions from two contrasting dairy systems: a seasonal calving pasture-based dairy farm and a total confinement dairy system. Data used to quantify emissions from these systems originated from a research study carried out over a 1-year period in Ireland. The genetic merit of cows modelled was similar for both systems. Total mixed ration was fed in the Confinement system, whereas grazed grass was mainly fed in the grass-based system. GHG emissions from these systems were quantified per unit of product and area. The results of both methods showed that the dairy system that emitted the lowest GHG emissions per unit area did not necessarily emit the lowest GHG emissions possible for a given level of product. Consequently, a recommendation from this study is that GHG emissions be evaluated per unit of product given the growing affluent human population and increasing demand for dairy products. The IPCC and LCA methods ranked dairy systems' GHG emissions differently. For instance, the IPCC method quantified that the Confinement system reduced GHG emissions per unit of product by 8% compared with the grass-based system, but the LCA approach calculated that the Confinement system increased emissions by 16% when off-farm emissions associated with primary dairy production were included. Thus, GHG emissions should be quantified using approaches that quantify the total GHG emissions associated with the production system, so as to determine whether the dairy system was causing emissions displacement. The IPCC and LCA methods were also used in this study to simulate, through a dairy farm GHG model, what effect management changes within both production systems have on GHG emissions. The findings suggest that single changes have a small mitigating effect on GHG emissions (<5%), except for strategies used to control emissions from manure storage in the Confinement system (14% to 24%). However, when several management strategies were combined, GHG emissions per unit of product could be reduced significantly (15% to 30%). The LCA method was identified as the preferred approach to assess the effect of management changes on GHG emissions, but the analysis indicated that further standardisation of the approach is needed given the sensitivity of the approach to allocation decisions regarding milk and meat.
NASA Astrophysics Data System (ADS)
Song, Xia; Hoffman, Forrest M.; Iversen, Colleen M.; Yin, Yunhe; Kumar, Jitendra; Ma, Chun; Xu, Xiaofeng
2017-09-01
Earth system models (ESMs) have been widely used for projecting global vegetation carbon dynamics, yet how well ESMs performed for simulating vegetation carbon density remains untested. We compiled observational data of vegetation carbon density from literature and existing data sets to evaluate nine ESMs at site, biome, latitude, and global scales. Three variables—root (including fine and coarse roots), total vegetation carbon density, and the root:total vegetation carbon ratios (R/T ratios), were chosen for ESM evaluation. ESM models performed well in simulating the spatial distribution of carbon densities in root (
A decision-making framework for total ownership cost management of complex systems: A Delphi study
NASA Astrophysics Data System (ADS)
King, Russel J.
This qualitative study, using a modified Delphi method, was conducted to develop a decision-making framework for the total ownership cost management of complex systems in the aerospace industry. The primary focus of total ownership cost is to look beyond the purchase price when evaluating complex system life cycle alternatives. A thorough literature review and the opinions of a group of qualified experts resulted in a compilation of total ownership cost best practices, cost drivers, key performance factors, applicable assessment methods, practitioner credentials and potential barriers to effective implementation. The expert panel provided responses to the study questions using a 5-point Likert-type scale. Data were analyzed and provided to the panel members for review and discussion with the intent to achieve group consensus. As a result of the study, the experts agreed that a total ownership cost analysis should (a) be as simple as possible using historical data; (b) establish cost targets, metrics, and penalties early in the program; (c) monitor the targets throughout the product lifecycle and revise them as applicable historical data becomes available; and (d) directly link total ownership cost elements with other success factors during program development. The resultant study framework provides the business leader with incentives and methods to develop and implement strategies for controlling and reducing total ownership cost over the entire product life cycle when balancing cost, schedule, and performance decisions.
ERIC Educational Resources Information Center
Wilson, Joshua
2017-01-01
The present study examined growth in writing quality associated with feedback provided by an automated essay evaluation system called PEG Writing. Equal numbers of students with disabilities (SWD) and typically-developing students (TD) matched on prior writing achievement were sampled (n = 1196 total). Data from a subsample of students (n = 655)…
ERIC Educational Resources Information Center
Putnam, Robert F.; Luiselli, James K.; Sennett, Kenneth; Malonson, Joanne
2002-01-01
Evaluation of out-of-district special education placement costs in the 15 largest Massachusetts public school districts found the criterion school district (which had developed a system-wide approach to behavioral intervention) had the lowest per capita cost, lowest percentage of total school budget consumed by out-of-district placements, and the…
A dynamic vulnerability evaluation model to smart grid for the emergency response
NASA Astrophysics Data System (ADS)
Yu, Zhen; Wu, Xiaowei; Fang, Diange
2018-01-01
Smart grid shows more significant vulnerability to natural disasters and external destroy. According to the influence characteristics of important facilities suffered from typical kinds of natural disaster and external destroy, this paper built a vulnerability evaluation index system of important facilities in smart grid based on eight typical natural disasters, including three levels of static and dynamic indicators, totally forty indicators. Then a smart grid vulnerability evaluation method was proposed based on the index system, including determining the value range of each index, classifying the evaluation grade standard and giving the evaluation process and integrated index calculation rules. Using the proposed evaluation model, it can identify the most vulnerable parts of smart grid, and then help adopting targeted emergency response measures, developing emergency plans and increasing its capacity of disaster prevention and mitigation, which guarantee its safe and stable operation.
Research on Livable Community Evaluation Based on GIS
NASA Astrophysics Data System (ADS)
Yin, Zhangcai; Wu, Yang; Jin, Zhanghaonan; Zhang, Xu
2018-01-01
Community is the basic unit of the city. Research on livable community could provide a bottom-up research path for the realization of livable city. Livability is the total factor affecting the quality of community life. In this paper, livable community evaluation indexes are evaluated based on GIS and fuzzy comprehensive evaluation method. Then the sum-index and sub-index of community livability are both calculated. And community livable evaluation index system is constructed based on the platform of GIS. This study provides theoretical support for the construction and management of livable communities, so as to guide the development and optimization of city.
Sports Injury Surveillance Systems: A Review of Methods and Data Quality.
Ekegren, Christina L; Gabbe, Belinda J; Finch, Caroline F
2016-01-01
Data from sports injury surveillance systems are a prerequisite to the development and evaluation of injury prevention strategies. This review aimed to identify ongoing sports injury surveillance systems and determine whether there are gaps in our understanding of injuries in certain sport settings. A secondary aim was to determine which of the included surveillance systems have evaluated the quality of their data, a key factor in determining their usefulness. A systematic search was carried out to identify (1) publications presenting methodological details of sports injury surveillance systems within clubs and organisations; and (2) publications describing quality evaluations and the quality of data from these systems. Data extracted included methodological details of the surveillance systems, methods used to evaluate data quality, and results of these evaluations. Following literature search and review, a total of 15 sports injury surveillance systems were identified. Data relevant to each aim were summarised descriptively. Most systems were found to exist within professional and elite sports. Publications concerning data quality were identified for seven (47%) systems. Validation of system data through comparison with alternate sources has been undertaken for only four systems (27%). This review identified a shortage of ongoing injury surveillance data from amateur and community sport settings and limited information about the quality of data in professional and elite settings. More surveillance systems are needed across a range of sport settings, as are standards for data quality reporting. These efforts will enable better monitoring of sports injury trends and the development of sports safety strategies.
Devi, P. Suganya; Kumar, M. Saravana; Das, S. Mohan
2012-01-01
There is increasing interest in natural food colorants like carotenoids and anthocyanins with functional properties. Red sorghum bran is known as a rich source for anthocyanins. The anthocyanin contents extracted from red sorghum bran were evaluated by biochemical analysis. Among the three solvent system used, the acidified methanol extract showed a highest anthocyanin content (4.7 mg/g of sorghum bran) followed by methanol (1.95 mg/g) and acetone (1 mg/g). Similarly, the highest total flavonoids (143 mg/g) and total phenolic contents (0.93 mg/g) were obtained in acidified methanol extracts than methanol and acetone extracts. To study the health benefits of anthocyanin from red sorghum bran, the total antioxidant activity was evaluated by biochemical and molecular methods. The highest antioxidant activity was observed in acidified methanol extracts of anthocyanin in dose-dependent manner. The antioxidant activity of the red sorghum bran was directly related to the total anthocyanin found in red sorghum bran. PMID:22400119
Marigo, Luca; D' Arcangelo, Camillo; DE Angelis, Francesco; Cordaro, Massimo; Vadini, Mirco; Lajolo, Carlo
2017-02-01
The purpose of this study was to evaluate the push-out bond strengths of four commercially available adhesive luting systems (two self-adhesive and two etch-and-rinse systems) after mechanical aging. Forty single-rooted anterior teeth were divided into four groups according to the luting cement system used: Cement-One (Group 1); One-Q-adhesive Bond + Axia Core Dual (Group 2); SmartCem® 2 (Group 3); and XP Bond® + Core-X™ Flow (Group 4). Anatomical Post was cemented in groups 1 and 2, and D.T. Light-Post Illusion was cemented in groups 3 and 4. All samples were subjected to masticatory stress simulation consisting of 300,000 cycles applied with a computer-controlled chewing simulator. Push-out bond strength values (MPa) were calculated at cervical, middle, and apical each level, and the total bond strengths were calculated as the averages of the three levels. Statistical analysis was performed with data analysis software and significance was set at P<0.05. Statistically significant differences in total bond strength were detected between the cements (Group 4: 3.28 MPa, Group 1: 2.77 MPa, Group 2: 2.36 MPa, Group 3: 1.13 MPa; P<0.05). Specifically, Group 1 exhibited a lower bond strength in the apical zone, Group 3 exhibited a higher strength in this zone, and groups 2 and 4 exhibited more homogeneous bonding strengths across the different anatomical zones. After artificial aging, etch-and-rinse luting systems exhibited more homogeneous bond strengths; nevertheless, Cement-One exhibited a total bond strength second only to Core-X Flow.
NASA Astrophysics Data System (ADS)
Moon, Byung-Young
2005-12-01
The hybrid neural-genetic multi-model parameter estimation algorithm was demonstrated. This method can be applied to structured system identification of electro-hydraulic servo system. This algorithms consist of a recurrent incremental credit assignment(ICRA) neural network and a genetic algorithm. The ICRA neural network evaluates each member of a generation of model and genetic algorithm produces new generation of model. To evaluate the proposed method, electro-hydraulic servo system was designed and manufactured. The experiment was carried out to figure out the hybrid neural-genetic multi-model parameter estimation algorithm. As a result, the dynamic characteristics were obtained such as the parameters(mass, damping coefficient, bulk modulus, spring coefficient), which minimize total square error. The result of this study can be applied to hydraulic systems in industrial fields.
Performance evaluation of a 1.6-µm methane DIAL system from ground, aircraft and UAV platforms.
Refaat, Tamer F; Ismail, Syed; Nehrir, Amin R; Hair, John W; Crawford, James H; Leifer, Ira; Shuman, Timothy
2013-12-16
Methane is an efficient absorber of infrared radiation and a potent greenhouse gas with a warming potential 72 times greater than carbon dioxide on a per molecule basis. Development of methane active remote sensing capability using the differential absorption lidar (DIAL) technique enables scientific assessments of the gas emission and impacts on the climate. A performance evaluation of a pulsed DIAL system for monitoring atmospheric methane is presented. This system leverages a robust injection-seeded pulsed Nd:YAG pumped Optical Parametric Oscillator (OPO) laser technology operating in the 1.645 µm spectral band. The system also leverages an efficient low noise, commercially available, InGaAs avalanche photo-detector (APD). Lidar signals and error budget are analyzed for system operation on ground in the range-resolved DIAL mode and from airborne platforms in the integrated path DIAL (IPDA) mode. Results indicate system capability of measuring methane concentration profiles with <1.0% total error up to 4.5 km range with 5 minute averaging from ground. For airborne IPDA, the total error in the column dry mixing ratio is less than 0.3% with 0.1 sec average using ground returns. This system has a unique capability of combining signals from the atmospheric scattering from layers above the surface with ground return signals, which provides methane column measurement between the atmospheric scattering layer and the ground directly. In such case 0.5% and 1.2% total errors are achieved with 10 sec average from airborne platforms at 8 km and 15.24 km altitudes, respectively. Due to the pulsed nature of the transmitter, the system is relatively insensitive to aerosol and cloud interferences. Such DIAL system would be ideal for investigating high latitude methane releases over polar ice sheets, permafrost regions, wetlands, and over ocean during day and night. This system would have commercial potential for fossil fuel leaks detection and industrial monitoring applications.
An Analysis of Total Quality Management in Aeronautical Systems Division
1991-09-01
Annual Review ..... ......... . 3-51 Disease 4: Mobility of Top Management ................... .3-52 Disease 5: Running a Company on Visible Figures...range Planning .................... 5-4 Merit Rating Systems and Annual Evaluation of Performance .. ..... ........... 5-4 Mobility of Management...generations of careful quality-conscious buyers. The indus- trial engine ran on the talents of designers, packagers, and advertisers . Turning out new
TRSys: A hardwood lumber grading training and remanufacturing system
P. Klinkhachorn; R. Kothari; R. Annavajjhala; Charles W. McMillin
1994-01-01
The Training and Remanufacturing System (TRSys) is a new training tool for teaching both hardwood lumber grading and remanufacturing of lower grade boards into smaller boards of higher total value. TRSys is based on the HaLT2, ReGS, and enhanced HaRem computer programs. The most important feature of this new program is its ablilty to evaluate remanufacturing beyond...
TRSys: a hardwood lumber grading training and remanufacturing system
P. Klinkhachorn; R. Kotharl; R. annavajjhala; Charles W. McMilling
1994-01-01
The training and remanufacturing system( TRsys) is a new training tool for teaching both hardwood lumber and grading and remanufacturing of lower grade boards into smaller boards of higher total value. TRSys is based on HaLT2. REGS, and enhanced HARem computer programs. The mosti mportant feature of this new program is its ability to evaluate remanufacturing beyond...
Development and Evaluation of Self-Applied Plaque Indices for Children.
ERIC Educational Resources Information Center
Hunter, Harold G.; And Others
This paper reports on one of the main goals of preventive dentistry, that is, encouraging children to remove plaque at least once a day. Two self-scoring systems were combined with two disclosants for a total of four experimental systems administered to 128 children. In the count method, the child counts the number of stained teeth; in the rating…
Cerebral venous circulatory system evaluation by ultrasonography.
Zavoreo, Iris; Basić-Kes, Vanja; Zadro-Matovina, Lucija; Lisak, Marijana; Corić, Lejla; Cvjeticanin, Timon; Ciliga, Dubravka; Bobić, Tatjana Trost
2013-06-01
Venous system can be classified as pulmonary veins, systemic veins and venous sinuses that are present only within the skull. Cerebral venous system is divided into two main parts, the superficial and the deep system. The main assignment of veins is to carry away deoxygenated blood and other maleficient materials from the tissues towards the heart. Veins have thinner walls and larger lumina than arteries. Between 60% and 70% of the total blood volume is found in veins. The major factors that influence venous function are the respiratory cycle, venous tone, the function of the right heart, gravity, and the muscle pump. Venous system, in general, can be presented by selective venography, Doppler sonography, computed tomography (CT) venography and magnetic resonance (MR) venography, and cerebral venous system can be displayed by selective venography, cerebral CT venography, cerebral MR venography, and specialized extracranial and transcranial Doppler sonography. The aim of this paper is to show the possibilities of intracranial and extracranial ultrasound evaluation of the head and neck venous circulation and chronic cerebrospinal venous insufficiency as one of the most common pathologies evaluated as part of neurodegenerative processes in the central nervous system.
Sakwari, Gloria
2013-01-01
Introduction: Endotoxin exposure associated with organic dust exposure has been studied in several industries. Coffee cherries that are dried directly after harvest may differ in dust and endotoxin emissions to those that are peeled and washed before drying. The aim of this study was to measure personal total dust and endotoxin levels and to evaluate their determinants of exposure in coffee processing factories. Methods: Using Sidekick Casella pumps at a flow rate of 2l/min, total dust levels were measured in the workers’ breathing zone throughout the shift. Endotoxin was analyzed using the kinetic chromogenic Limulus amebocyte lysate assay. Separate linear mixed-effects models were used to evaluate exposure determinants for dust and endotoxin. Results: Total dust and endotoxin exposure were significantly higher in Robusta than in Arabica coffee factories (geometric mean 3.41mg/m3 and 10 800 EU/m3 versus 2.10mg/m3 and 1400 EU/m3, respectively). Dry pre-processed coffee and differences in work tasks explained 30% of the total variance for total dust and 71% of the variance for endotoxin exposure. High exposure in Robusta processing is associated with the dry pre-processing method used after harvest. Conclusions: Dust and endotoxin exposure is high, in particular when processing dry pre-processed coffee. Minimization of dust emissions and use of efficient dust exhaust systems are important to prevent the development of respiratory system impairment in workers. PMID:23028014
The plan for the economic evaluation of the Public Service Communication Satellite system
NASA Technical Reports Server (NTRS)
1977-01-01
A total plan for the economic evaluation of the PSCS public service communication satellite program within domestic markets is presented. It extends from the present through the planning, performance and evaluation of economic experiments following the launch of the PSCS, and includes the consideration of how the results of these experiments impact the transfer from demonstration to operations. The implementation of this plan will provide NASA with information needed to understand and manage the economic and social impacts of the PSCS program.
Chen, X; Fujiwara, T; Ohtoshi, K; Inamori, S; Nakamachi, K; Tsuno, H
2010-01-01
A novel oxidation ditch system using anaerobic tanks and innovative dual dissolved oxygen (DO) control technology is proposed for biological nitrogen and phosphorus removal from domestic sewage. A continuous bench-scale experiment running for more than 300 days was performed to evaluate the system. Monitoring and controlling the airflow and recirculation flow rate independently using DO values at two points along the ditch permitted maintenance of aerobic and anoxic zone ratios of around 0.30 and 0.50, respectively. The ability to optimize aerobic and anoxic zone ratios using the dual DO control technology meant that a total nitrogen removal efficiency of 83.2-92.9% could be maintained. This remarkable nitrogen removal performance minimized the nitrate recycle to anaerobic tanks inhibiting the phosphorus release. Hence, the total phosphorus removal efficiency was also improved and ranged within 72.6-88.0%. These results demonstrated that stabilization of the aerobic and anoxic zone ratio by dual DO control technology not only resulted in a marked improvement of nitrogen removal, but it also enhanced phosphorus removal.
Test and evaluation of the 2.4-micron photorefractor ocular screening system
NASA Technical Reports Server (NTRS)
Richardson, J. R.
1985-01-01
An improved 2.4-m photorefractor ocular screening system was tested and evaluated. The photorefractor system works on the principal of obtaining a colored photograph of both human eyes; and, by analysis of the retinal reflex images, certain ocular defects can be detected such a refractive error, strabismus, and lens obstructions. The 2.4-m photorefractory system uses a 35-mm camera with a telephoto lens and an electronic flash attachment. Retinal reflex images obtained from the new 2.4-m system are significantly improved over earlier systems in image quality. Other features were also improved, notably portability and reduction in mass. A total of 706 school age children were photorefracted, 211 learning disabled and 495 middle school students. The total students having abnormal retinal reflexes were 156 or 22 percent, and 133 or 85 percent of the abnormal had refractive error indicated. Ophthalmological examination was performed on 60 of these students and refractive error was verified in 57 or 95 percent of those examined. The new 2.4-m system has a NASA patent pending and is authorized by the FDA. It provides a reliable means of rapidly screening the eyes of children and young adults for vision problems. It is especially useful for infants and other non-communicative children who cannot be screened by the more conventional methods such as the familiar E chart.
NASA Technical Reports Server (NTRS)
1980-01-01
The system's operational performance from May 1979 through April 1980 is described. Solar energy satisfied 23 percent of the total performance load, which was significantly below the design value of 56 percent. A fossil savings of 80.89 million Btu's or 578 gallons of fuel oil is estimated. If uncontrolled losses could have been reduced to an inconsequential level, the system's efficiency would have been improved considerably.
Implantable telemetry for small animals
NASA Astrophysics Data System (ADS)
1982-03-01
A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.
Implantable telemetry for small animals
NASA Technical Reports Server (NTRS)
1982-01-01
A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.
Ship Underwater Threat Response System (SUTRS): A Feasibility Study of Organic Mine Point-Defense
2012-09-01
by implementing and testing the design until a final product has been established that addresses (and has been traced throughout to) the...The assumptions used to evaluate those TPMs are as follows: • The threshold Probability of Success for the total system should be 90% survival...Threat Response System xviii TOA Table of Allowance TPM Technical Performance Measures TTP Tactics Techniques and Procedures U.S. United
Biological groundwater treatment for chromium removal at low hexavalent chromium concentrations.
Mamais, Daniel; Noutsopoulos, Constantinos; Kavallari, Ioanna; Nyktari, Eleni; Kaldis, Apostolos; Panousi, Eleni; Nikitopoulos, George; Antoniou, Kornilia; Nasioka, Maria
2016-06-01
The objective of this work is to develop and evaluate biological groundwater treatment systems that will achieve hexavalent chromium reduction and total chromium removal from groundwater at hexavalent chromium (Cr(VI)) groundwater concentrations in the 0-200 μg/L range. Three lab-scale units operated, as sequencing batch reactors (SBR) under aerobic, anaerobic and anaerobic-aerobic conditions. All systems received groundwater with a Cr(VI) content of 200 μg/L. In order to support biological growth, groundwater was supplemented with milk, liquid cheese whey or a mixture of sugar and milk to achieve a COD concentration of 200 mg/L. The results demonstrate that a fully anaerobic system or an anaerobic-aerobic system dosed with simple or complex external organic carbon sources can lead to practically complete Cr(VI) reduction to Cr(III). The temperature dependency of maximum Cr(VI) removal rates can be described by the Arrhenius relationship. Total chromium removal in the biological treatment systems was not complete because a significant portion of Cr(III) remained in solution. An integrated system comprising of an anaerobic SBR followed by a sand filter achieved more than 95% total chromium removal thus resulting in average effluent total and dissolved chromium concentrations of 7 μg/L and 3 μg/L, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhang, Xiaoxia; Lin, Zongtao; Fang, Jinggui; Liu, Meixian; Niu, Yanyan; Chen, Shizhong; Wang, Hong
2015-10-02
An on-line high-performance liquid chromatography-diode-array detector-electrospray ionization-ion-trap-time-of-flight-mass spectrometry-total antioxidant capacity detection (HPLC-DAD-ESI-IT-TOF-MS-TACD) system was created for identification and evaluation of antioxidants in Prunus (P.) mume flowers. Applying this system, the HPLC fingerprint, ultraviolet (UV) spectra, mass fragmentations, active profiles against 1,1-diphenylpicryl-2-hydrazyl radical (DPPH•) scavenging activity and ferric reducing antioxidant power (FRAP) of each complex sample were obtained simultaneously after one injection. Synchronous structure identification and activities screening of complex samples were thus accomplished. In this study, 78 compounds were identified from P. mume flowers by their chromatographic behaviors, UV spectra and MS data with the assistance of standard compounds and literature reports. The DPPH and FRAP activity of 24 samples (23 different P. mume varieties and 1 related herbal medicine) were then quantified by their detailed activity profiles from the on-line system, and by the total activity of each sample extract from off-line 96-well plate method. As a result, 21 and 32 compounds in the on-line system showed anti-oxidative effects against DPPH and FRAP, respectively. The established on-line system is efficient, sensitive and reliable to tell the DPPH and FRAP antioxidant activities of individual compound in complex samples, and therefore would be a useful and promising technique for antioxidant screening from different food and medicinal matrices. Copyright © 2015 Elsevier B.V. All rights reserved.
Cherenkov imaging for Total Skin Electron Therapy (TSET)
NASA Astrophysics Data System (ADS)
Xie, Yunhe; Petroccia, Heather; Maity, Amit; Miao, Tianshun; Zhu, Yihua; Bruza, Petr; Pogue, Brian W.; Andreozzi, Jacqueline M.; Plastaras, John P.; Dong, Lei; Zhu, Timothy C.
2018-03-01
Total Skin Electron Therapy (TSET) utilizes high-energy electrons to treat cancers on the entire body surface. The otherwise invisible radiation beam can be observed via the optical Cherenkov photons emitted from interaction between the high-energy electron beam and tissue. Using a specialized camera-system, the Cherenkov emission can thus be used to evaluate the dose uniformity on the surface of the patient in real-time. Each patient was also monitored during TSET via in-vivo detectors (IVD) in nine locations. Patients undergoing TSET in various conditions (whole body and half body) were imaged and analyzed, and the viability of the system to provide clinical feedback was established.
Quality in Web-Supported Learning.
ERIC Educational Resources Information Center
Fresen, Jill
2002-01-01
Discusses quality assurance for Web-based courses, based on experiences at the University of Pretoria. Topics include evaluation of courseware; the concept of quality, including quality control, quality assurance, and total quality management; implementing a quality management system; measurement techniques; and partnerships. (LRW)
DOT National Transportation Integrated Search
2008-01-01
The Virginia Department of Transportation (VDOT) currently uses the results of automated surface distress surveys to assist in developing pavement maintenance strategies for its interstate and primary roadways. Totaling nearly 27,000 lane-miles, thes...
Bett, R C; Kosgey, I S; Bebe, B O; Kahi, A K
2007-10-01
A deterministic model was developed and applied to evaluate biological and economic variables that characterize smallholder production systems utilizing the Kenya Dual Purpose goat (KDPG) in Kenya. The systems were defined as: smallholder low-potential (SLP), smallholder medium-potential (SMP) and smallholder high-potential (SHP). The model was able to predict revenues and costs to the system. Revenues were from sale of milk, surplus yearlings and cull-forage animals, while costs included those incurred for feeds, husbandry, marketing and fixed asset (fixed costs). Of the total outputs, revenue from meat and milk accounted for about 55% and 45%, respectively, in SMP and 39% and 61% in SHP. Total costs comprised mainly variable costs (98%), with husbandry costs being the highest in both SMP and SLP. The total profit per doe per year was KSh 315.48 in SMP, KSh -1352.75 in SLP and KSh -80.22 in SHP. Results suggest that the utilization of the KDPG goat in Kenya is more profitable in the smallholder medium-potential production system. The implication for the application of the model to smallholder production systems in Kenya is discussed.
General specifications for the development of a PC-based simulator of the NASA RECON system
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Triantafyllopoulos, Spiros
1984-01-01
The general specifications for the design and implementation of an IBM PC/XT-based simulator of the NASA RECON system, including record designs, file structure designs, command language analysis, program design issues, error recovery considerations, and usage monitoring facilities are discussed. Once implemented, such a simulator will be utilized to evaluate the effectiveness of simulated information system access in addition to actual system usage as part of the total educational programs being developed within the NASA contract.
System Simulation by Recursive Feedback: Coupling a Set of Stand-Alone Subsystem Simulations
NASA Technical Reports Server (NTRS)
Nixon, D. D.
2001-01-01
Conventional construction of digital dynamic system simulations often involves collecting differential equations that model each subsystem, arran g them to a standard form, and obtaining their numerical gin solution as a single coupled, total-system simultaneous set. Simulation by numerical coupling of independent stand-alone subsimulations is a fundamentally different approach that is attractive because, among other things, the architecture naturally facilitates high fidelity, broad scope, and discipline independence. Recursive feedback is defined and discussed as a candidate approach to multidiscipline dynamic system simulation by numerical coupling of self-contained, single-discipline subsystem simulations. A satellite motion example containing three subsystems (orbit dynamics, attitude dynamics, and aerodynamics) has been defined and constructed using this approach. Conventional solution methods are used in the subsystem simulations. Distributed and centralized implementations of coupling have been considered. Numerical results are evaluated by direct comparison with a standard total-system, simultaneous-solution approach.
NASA Technical Reports Server (NTRS)
1978-01-01
A total wash water renovation system concept was developed for removing objectionable materials from spacecraft wash water in order to make the water reusable. The breadboard model system described provides for pretreatment with ferric chloride to remove soap by chemical precipitation, carbon adsorption to remove trace dissolved organics, and ion exchange for removal of dissolved salts. The entire system was put into continuous operation and carefully monitored to assess overall efficiency and equipment maintenance problems that could be expected in actual use. In addition, the capacity of the carbon adsorbers and the ion-exchange resin was calculated and taken into consideration in the final evaluation of the system adequacy. The product water produced was well within the Tentative Wash Water Standards with regard to total organic carbon, conductivity, urea content, sodium chloride content, color, odor, and clarity.
Evaluating Microbial Indicators of Environmental Condition in Oregon Rivers
NASA Astrophysics Data System (ADS)
Pennington, Alan T.; Harding, Anna K.; Hendricks, Charles W.; Campbell, Heidi M. K.
2001-12-01
Traditional bacterial indicators used in public health to assess water quality and the Biolog® system were evaluated to compare their response to biological, chemical, and physical habitat indicators of stream condition both within the state of Oregon and among ecoregion aggregates (Coast Range, Willamette Valley, Cascades, and eastern Oregon). Forty-three randomly selected Oregon river sites were sampled during the summer in 1997 and 1998. The public health indicators included heterotrophic plate counts (HPC), total coliforms (TC), fecal coliforms (FC) and Escherichia coli (EC). Statewide, HPC correlated strongly with physical habitat (elevation, riparian complexity, % canopy presence, and indices of agriculture, pavement, road, pasture, and total disturbance) and chemistry (pH, dissolved O2, specific conductance, acid-neutralizing capacity, dissolved organic carbon, total N, total P, SiO2, and SO4). FC and EC were significantly correlated generally with the river chemistry indicators. TC bacteria significantly correlated with riparian complexity, road disturbance, dissolved O2, and SiO2 and FC. Analyzing the sites by ecoregion, eastern Oregon was characterized by high HPC, FC, EC, nutrient loads, and indices of human disturbance, whereas the Cascades ecoregion had correspondingly low counts of these indicators. The Coast Range and Willamette Valley presented inconsistent indicator patterns that are more difficult to characterize. Attempts to distinguish between ecoregions with the Biolog system were not successful, nor did a statistical pattern emerge between the first five principle components and the other environmental indicators. Our research suggests that some traditional public health microbial indicators may be useful in measuring the environmental condition of lotic systems.
Morishita, K; Okumura, H; Ito, N; Takahashi, N
2001-08-28
The present study was conducted to confirm the usefulness of a primary culture system of adrenocortical cells from dogs for detecting the direct effects of the chemicals on adrenal cortex. Corticosteroid levels in the culture supernatant were measured using high-performance liquid chromatography (HPLC) following 24-h incubation with the chemicals. Ketoconazole, miconazole, metyrapone, aminoglutethimide, and 1-(o-chlorophenyl)-1-(p-chlorophenyl)-2,2-dichloroethane (o,p-DDD), which were known to inhibit cortisol production were evaluated in this system. Both viable cells and corticosteroid levels were decreased by o,p-DDD treatment. Other chemicals showed various inhibition patterns of corticosteroid levels as follows without affecting cell viability. Ketoconazole decreased total corticosteroids level by mainly due to the decreases in cortisol and 11-deoxycortisol levels. Miconazole decreased cortisol and 11-deoxycortisol levels, however, slightly increased corticosterone level. Metyrapone decreased cortisol and corticosterone levels as 11-deoxycortisol and 11-deoxycorticosterone levels were increased. Aminoglutethimide decreased total corticosteroids level by mainly decreasing cortisol, corticosterone and 11-deoxycortisol levels. These results suggested that determination of the pattern of corticosteroid levels by HPLC in this system well reflected the mode of their action on steroidogenesis. Thus, we conclude this simple system was useful to determine the direct effects of chemicals on steroidogenesis in the adrenal cortex.
Saravanan, A. V.; Ravishankar, P. L.; Kumar, Pradeep; Rajapandian, K.; Kalaivani, V.; Rajula, M. Prem Blaisie
2017-01-01
Aim: The present study was conducted to evaluate the serum triglycerides, serum cholesterol, total protein, and IgG levels in elderly patients who were affected by periodontal disease. Materials and Methods: This study was conducted at the Rajah Muthiah Dental College and Hospital in the periodontics division. The study was conducted for a period of 3 months. This study is a prospective analytical study. Sixty individuals who were systemically healthy in the age group of 50 and above were included in this study. Control and experimental groups of 30 participants each were included. Plaque index, gingival index, probing pocket depth, and clinical attachment loss were recorded. Biochemical parameters such as serum cholesterol, serum triglycerides, total protein, and IgG levels were also evaluated and correlated with the periodontal parameters. Data was analyzed using SPSS version 16.0 (IBM Corp., Armonk, NY). The relationship between periodontal status and the biochemical parameters such as serum cholesterol, serum triglycerides, total protein, and IgG levels were evaluated by Student's t-test. Results: There was no significant difference in the plaque and gingival scores between the experimental and control group. It was observed that serum cholesterol level and total protein level was lower in participants suffering from chronic periodontitis. Triglycerides level was significantly elevated in the experimental group. IgG, a level which is not significant, concluded that there is no difference in control and experimental group. Conclusion: It was concluded from the results obtained from the study that there is an association between serum triglycerides, serum cholesterol, total protein, and periodontal disease. However, further longitudinal and well-controlled studies are required to evaluate the relationship between these biochemical parameters and periodontal disease. PMID:28462181
Saravanan, A V; Ravishankar, P L; Kumar, Pradeep; Rajapandian, K; Kalaivani, V; Rajula, M Prem Blaisie
2017-01-01
The present study was conducted to evaluate the serum triglycerides, serum cholesterol, total protein, and IgG levels in elderly patients who were affected by periodontal disease. This study was conducted at the Rajah Muthiah Dental College and Hospital in the periodontics division. The study was conducted for a period of 3 months. This study is a prospective analytical study. Sixty individuals who were systemically healthy in the age group of 50 and above were included in this study. Control and experimental groups of 30 participants each were included. Plaque index, gingival index, probing pocket depth, and clinical attachment loss were recorded. Biochemical parameters such as serum cholesterol, serum triglycerides, total protein, and IgG levels were also evaluated and correlated with the periodontal parameters. Data was analyzed using SPSS version 16.0 (IBM Corp., Armonk, NY). The relationship between periodontal status and the biochemical parameters such as serum cholesterol, serum triglycerides, total protein, and IgG levels were evaluated by Student's t-test. There was no significant difference in the plaque and gingival scores between the experimental and control group. It was observed that serum cholesterol level and total protein level was lower in participants suffering from chronic periodontitis. Triglycerides level was significantly elevated in the experimental group. IgG, a level which is not significant, concluded that there is no difference in control and experimental group. It was concluded from the results obtained from the study that there is an association between serum triglycerides, serum cholesterol, total protein, and periodontal disease. However, further longitudinal and well-controlled studies are required to evaluate the relationship between these biochemical parameters and periodontal disease.
Al Haddabi, Buthaina; Al Lawati, Haider A J; Suliman, FakhrEldin O
2016-04-01
Two chemiluminescence-microfluidic (CL-MF) systems, e.g., Ce(IV)-rhodamine B (RB) and Ce(IV)-rhodamine 6G (R6G), for the determination of the total phenolic content in teas and some sweeteners were evaluated. The results indicated that the Ce(IV)-R6G system was more sensitive in comparison to the Ce(IV)-RB CL system. Therefore, a simple (CL-MF) method based on the CL of Ce(IV)-R6G was developed, and the sensitivity, selectivity and stability of this system were evaluated. Selected phenolic compounds (PCs), such as quercetin (QRC), catechin (CAT), rutin (RUT), gallic acid (GA), caffeic acid (CA) and syringic acid (SA), produced analytically useful chemiluminescence signals with low detection limits ranging from 0.35 nmol L(-1) for QRC to 11.31 nmol L(-1) for SA. The mixing sequence and the chip design were crucial, as the sensitivity and reproducibility could be substantially affected by these two factors. In addition, the anionic surfactant (i.e., sodium dodecyl sulfate (SDS)) can significantly enhance the CL signal intensity by as much as 300% for the QRC solution. Spectroscopic studies indicated that the enhancement was due to a strong guest-host interaction between the cationic R6G molecules and the anionic amphiphilic environment. Other parameters that could affect the CL intensities of the PCs were carefully optimized. Finally, the method was successfully applied to tea and sweetener samples. Six different tea samples exhibited total phenolic/antioxidant levels from 7.32 to 13.5 g per 100g of sample with respect to GA. Four different sweetener samples were also analyzed and exhibited total phenolic/antioxidant levels from 500.9 to 3422.9 mg kg(-1) with respect to GA. The method was selective, rapid and sensitive when used to estimate the total phenolic/antioxidant level, and the results were in good agreement with those reported for honey and tea samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Hu, Ting; He, Xiao-Wei; Jiang, Jian-Guo; Xu, Xi-Lin
2014-05-01
In order to evaluate the health effects of Ilex latifolia Thunb., a Chinese bitter tea widely consumed as a health beverage, flavonoids, saponins, polysaccharides and alkaloids were extracted from its leaves and their in vitro antioxidant activity, anticomplement system activity, antiproliferative effects against human cervical carcinoma Hela cells, and anti-inflammatory effects against mouse macrophage RAW 264.7 cells were analyzed. Results showed that the polysaccharides exhibited a considerable inhibition of the complement system, the hemolysis inhibition rate reached 98% at a concentration of 0.8 mg mL(-1), which was clearly higher than that of the positive control (heparin sodium). The total flavonoids displayed significant DPPH scavenging activity and an inhibition effect on the generation of NO in LPS-induced RAW 264.7 macrophages. In addition, the total saponins showed a better antiproliferative effect against Hela cells, and the total alkaloids exhibited a high reducing power. It is obvious that I. latifolia has a variety of nutritional and health functions which are attributed to its different components. The analysis method presented in this research can suggest lessons for analysis of other plant foods.
NASA Astrophysics Data System (ADS)
Leiva, Josue Nahun; Robbins, James; Saraswat, Dharmendra; She, Ying; Ehsani, Reza
2017-07-01
This study evaluated the effect of flight altitude and canopy separation of container-grown Fire Chief™ arborvitae (Thuja occidentalis L.) on counting accuracy. Images were taken at 6, 12, and 22 m above the ground using unmanned aircraft systems. Plants were spaced to achieve three canopy separation treatments: 5 cm between canopy edges, canopy edges touching, and 5 cm of canopy edge overlap. Plants were placed on two different ground covers: black fabric and gravel. A counting algorithm was trained using Feature Analyst®. Total counting error, false positives, and unidentified plants were reported for images analyzed. In general, total counting error was smaller when plants were fully separated. The effect of ground cover on counting accuracy varied with the counting algorithm. Total counting error for plants placed on gravel (-8) was larger than for those on a black fabric (-2), however, false positive counts were similar for black fabric (6) and gravel (6). Nevertheless, output images of plants placed on gravel did not show a negative effect due to the ground cover but was impacted by differences in image spatial resolution.
Design, construction and evaluation of a system of forced solar water heating.
NASA Astrophysics Data System (ADS)
Hernández, E.; Bautista, G. A.; Ortiz, I. L.
2016-07-01
The main purpose of this project was to design, construct and evaluate a system of forced solar water heating for domestic consumption, at the Universidad Pontificia Bolivariana-Bucaramanga, Colombia; using solar energy. This is a totally system independent of the electrical grid and an important characteristic is the heating water doesn't mix with the consumption water. The system receives the solar radiation through a flat-plate collector, which it transmits the heat to the water that it flow with impulse from the centrifugal pump of 12VDC, the water circulates toward helical serpentine it is inside of the tank of the storage whose capacity is 100 liters of water. The temperature of the tank is regulated with a controller in such a way that de-energized the pump when it gets the temperature required. The performance thermal or efficiency of the system was evaluated like a relationship between the delivered energy to the water in storage tank and the incident energy in the flat-plate collector.
Evaluation of milk quality in delivering sterilized milk with soft tank transportation system.
Tsukamoto, C; Rula, Sa; Asano, H; Ando, K
2009-09-01
A new transportation system is proposed recently to improve the defects of liquid transportation by tank trucks. This method is called "soft tank transportation system"; a driver installs a sac-like container (soft tank), which is made from a tarpaulin with high-pressure resistant-waterproof zippers, in a general cargo vehicle. To evaluate the quality of sterilized milk by using the soft tank transportation system, ground and marine transportation for a long distance which took about 36 h from the shipper's loading to the receiver's unloading in a high-temperature summer season (average outside temperature was 33.4 degrees C) were carried out. Although the difference of milk temperature before and after the delivery varied from -0.7 to +1.4 degrees C, there was no difference in milk quality (fat, nonfat solids, total dissolved solids, and pH) and no coliform bacteria were detected. It can be evaluated that sterilized milk was carried in keeping good conditions by soft tank transportation system.
Upper stages utilizing electric propulsion
NASA Technical Reports Server (NTRS)
Byers, D. C.
1980-01-01
The payload characteristics of geocentric missions which utilize electron bombardment ion thruster systems are discussed. A baseline LEO to GEO orbit transfer mission was selected to describe the payload capabilities. The impacts on payloads of both mission parameters and electric propulsion technology options were evaluated. The characteristics of the electric propulsion thrust system and the power requirements were specified in order to predict payload mass. This was completed by utilizing a previously developed methodology which provides a detailed thrust system description after the final mass on orbit, the thrusting time, and the specific impulse are specified. The impact on payloads of total mass in LEO, thrusting time, propellant type, specific impulse, and power source characteristics was evaluated.
Electric propulsion options for 10 kW class earth space missions
NASA Technical Reports Server (NTRS)
Patterson, M. J.; Curran, Francis M.
1989-01-01
Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment have been evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA II 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10(7) to 2.1x10(7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA II 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10(6) to 3.6x10(6) N-s, and approximately 662 to 1072 m/s, respectively.
Zacarias Sylvestre, Silvia Helena; Lux Hoppe, Estevam Guilherme; de Oliveira, Roberto Alves
2014-01-01
The present work evaluated the performance of two treatment systems in reducing indicators of biological contamination in swine production wastewater. System I consisted of two upflow anaerobic sludge blanket (UASB) reactors, with 510 and 209 L in volume, being serially arranged. System II consisted of a UASB reactor, anaerobic filter, trickling filter, and decanter, being also organized in series, with volumes of 300, 190, 250, and 150 L, respectively. Hydraulic retention times (HRT) applied in the first UASB reactors were 40, 30, 20, and 11 h in systems I and II. The average removal efficiencies of total and thermotolerant coliforms in system I were 92.92% to 99.50% and 94.29% to 99.56%, respectively, and increased in system II to 99.45% to 99.91% and 99.52% to 99.93%, respectively. Average removal rates of helminth eggs in system I were 96.44% to 99.11%, reaching 100% as in system II. In reactor sludge, the counts of total and thermotolerant coliforms ranged between 105 and 109 MPN (100 mL)−1, while helminth eggs ranged from 0.86 to 9.27 eggs g−1 TS. PMID:24812560
Analysis of inlet flow distortion and turbulence effects on compressor stability
NASA Technical Reports Server (NTRS)
Melick, H. C., Jr.
1973-01-01
The effect of steady state circumferential total pressure distortion on the loss in compressor stall pressure ratio has been established by analytical techniques. Full scale engine and compressor/fan component test data were used to provide direct evaluation of the analysis. Specifically, since a circumferential total pressure distortion in an inlet system will result in unsteady flow in the coordinate system of the rotor blades, analysis of this type distortion must be performed from an unsteady aerodynamic point of view. By application of the fundamental aerothermodynamic laws to the inlet/compressor system, parameters important in the design of such a system for compatible operation have been identified. A time constant, directly related to the compressor rotor chord, was found to be significant, indicating compressor sensitivity to circumferential distortion is directly dependent on the rotor chord.
Highlights of recent balance of system research and evaluation
NASA Astrophysics Data System (ADS)
Thomas, M. G.; Stevens, J. W.
The cost of most photovoltaic (PV) systems is more a function of the balance of system (BOS) components than the collectors. The exception to this rule is the grid-tied system whose cost is related more directly to the collectors, and secondarily to the inverter/controls. In fact, recent procurements throughout the country document that collector costs for roof-mounted, utility-tied systems (Russell, PV Systems Workshop, 7/94) represent 60% to 70% of the system cost. This contrasts with the current market for packaged stand-alone all PV or PV-hybrid systems where collectors represent only 25% to 35% of the total. Not only are the BOS components the cost drivers in the current cost-effective PV system market place, they are also the least reliable components. This paper discusses the impact that BOS issues have on component performance, system performance, and system cost and reliability. We will also look at recent recommended changes in system design based upon performance evaluations of fielded PV systems.
A stochastic approach for automatic generation of urban drainage systems.
Möderl, M; Butler, D; Rauch, W
2009-01-01
Typically, performance evaluation of new developed methodologies is based on one or more case studies. The investigation of multiple real world case studies is tedious and time consuming. Moreover extrapolating conclusions from individual investigations to a general basis is arguable and sometimes even wrong. In this article a stochastic approach is presented to evaluate new developed methodologies on a broader basis. For the approach the Matlab-tool "Case Study Generator" is developed which generates a variety of different virtual urban drainage systems automatically using boundary conditions e.g. length of urban drainage system, slope of catchment surface, etc. as input. The layout of the sewer system is based on an adapted Galton-Watson branching process. The sub catchments are allocated considering a digital terrain model. Sewer system components are designed according to standard values. In total, 10,000 different virtual case studies of urban drainage system are generated and simulated. Consequently, simulation results are evaluated using a performance indicator for surface flooding. Comparison between results of the virtual and two real world case studies indicates the promise of the method. The novelty of the approach is that it is possible to get more general conclusions in contrast to traditional evaluations with few case studies.
NASA Technical Reports Server (NTRS)
Bodley, C. S.; Devers, D. A.; Park, C. A.
1975-01-01
A theoretical development and associated digital computer program system is presented. The dynamic system (spacecraft) is modeled as an assembly of rigid and/or flexible bodies not necessarily in a topological tree configuration. The computer program system may be used to investigate total system dynamic characteristics including interaction effects between rigid and/or flexible bodies, control systems, and a wide range of environmental loadings. Additionally, the program system may be used for design of attitude control systems and for evaluation of total dynamic system performance including time domain response and frequency domain stability analyses. Volume 1 presents the theoretical developments including a description of the physical system, the equations of dynamic equilibrium, discussion of kinematics and system topology, a complete treatment of momentum wheel coupling, and a discussion of gravity gradient and environmental effects. Volume 2, is a program users' guide and includes a description of the overall digital program code, individual subroutines and a description of required program input and generated program output. Volume 3 presents the results of selected demonstration problems that illustrate all program system capabilities.
Shan, Lingtong; Ge, Wen; Pu, Yiwei; Cheng, Hong; Cang, Zhengqiang; Zhang, Xing; Li, Qifan; Xu, Anyang; Wang, Qi; Gu, Chang; Zhang, Yangyang
2018-01-01
To assess and compare the predictive ability of three risk evaluation systems (SinoSCORE, EuroSCORE II and the STS risk evaluation system) in patients aged ≥70, and who underwent coronary artery bypass grafting (CABG) in East China. Three risk evaluation systems were applied to 1,946 consecutive patients who underwent isolated CABG from January 2004 to September 2016 in two hospitals. Patients were divided into two subsets according to their age: elderly group (age ≥70) with a younger group (age <70) used for comparison. The outcome of interest in this study was in-hospital mortality. The entire cohort and subsets of patients were analyzed. The calibration and discrimination in total and in subsets were assessed by the Hosmer-Lemeshow and the C statistics respectively. Institutional overall mortality was 2.52%. The expected mortality rates of SinoSCORE, EuroSCORE II and the STS risk evaluation system were 0.78(0.64)%, 1.43(1.14)% and 0.78(0.77)%, respectively. SinoSCORE achieved the best discrimination (the area under the receiver operating characteristic curve (AUC) = 0.829), followed by the STS risk evaluation system (AUC = 0.790) and EuroSCORE II (AUC = 0.769) in the entire cohort. In the elderly group, the observed mortality rate was 4.82% while it was 1.38% in the younger group. SinoSCORE (AUC = .829) also achieved the best discrimination in the elderly group, followed by the STS risk evaluation system (AUC = .730) and EuroSCORE II (AUC = 0.640) while all three risk evaluation systems all had good performances in the younger group. SinoSCORE, EuroSCORE II and the STS risk evaluation system all achieved positive calibrations in the entire cohort and subsets. The performance of the three risk evaluation systems was not ideal in the entire cohort. In the elderly group, SinoSCORE appeared to achieve better predictive efficiency than EuroSCORE II and the STS risk evaluation system.
NASA Technical Reports Server (NTRS)
Leininger, G.; Jutila, S.; King, J.; Muraco, W.; Hansell, J.; Lindeen, J.; Franckowiak, E.; Flaschner, A.
1975-01-01
A methodology is described for the evaluation of societal impacts associated with the implementation of a new technology. Theoretical foundations for the methodology, called the total assessment profile, are established from both the economic and social science perspectives. The procedure provides for accountability of nonquantifiable factors and measures through the use of a comparative value matrix by assessing the impacts of the technology on the value system of the society.
Monitoring total mixed rations and feed delivery systems.
Oelberg, Thomas J; Stone, William
2014-11-01
This article is intended to give practitioners a method to evaluate total mixed ration (TMR) consistency and to give them practical solutions to improve TMR consistency that will improve cattle performance and health. Practitioners will learn how to manage the variation in moisture and nutrients that exists in haylage and corn silage piles and in bales of hay, and methods to reduce variation in the TMR mixing and delivery process. Copyright © 2014 Elsevier Inc. All rights reserved.
Automotive Stirling Engine Development Program
NASA Technical Reports Server (NTRS)
Nightingale, N.; Ernst, W.; Richey, A.; Simetkosky, M.; Smith, G.; Rohdenburg, C.; Antonelli, M. (Editor)
1983-01-01
Program status and plans are discussed for component and technology development; reference engine system design, the upgraded Mod 1 engine; industry test and evaluation; and product assurance. Four current Mod 1 engines reached a total of 2523 operational hours, while two upgraded engines accumulated 166 hours.
Climate Conditioning for the Learning Environment.
ERIC Educational Resources Information Center
Perkins and Will, Architects, Chicago, IL.
Discusses heating, cooling, and ventilation for the classroom in relationship to students' learning abilities. It is designed to assist school boards, administrators, architects and engineers in understanding the beneficial effects of total climate control, and in evaluating the climate conditioning systems available for schools. Discussion…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powell, Danny H; Elwood Jr, Robert H
2011-01-01
Analysis of the material protection, control, and accountability (MPC&A) system is necessary to understand the limits and vulnerabilities of the system to internal threats. A self-appraisal helps the facility be prepared to respond to internal threats and reduce the risk of theft or diversion of nuclear material. The material control and accountability (MC&A) system effectiveness tool (MSET) fault tree was developed to depict the failure of the MPC&A system as a result of poor practices and random failures in the MC&A system. It can also be employed as a basis for assessing deliberate threats against a facility. MSET uses faultmore » tree analysis, which is a top-down approach to examining system failure. The analysis starts with identifying a potential undesirable event called a 'top event' and then determining the ways it can occur (e.g., 'Fail To Maintain Nuclear Materials Under The Purview Of The MC&A System'). The analysis proceeds by determining how the top event can be caused by individual or combined lower level faults or failures. These faults, which are the causes of the top event, are 'connected' through logic gates. The MSET model uses AND-gates and OR-gates and propagates the effect of event failure using Boolean algebra. To enable the fault tree analysis calculations, the basic events in the fault tree are populated with probability risk values derived by conversion of questionnaire data to numeric values. The basic events are treated as independent variables. This assumption affects the Boolean algebraic calculations used to calculate results. All the necessary calculations are built into the fault tree codes, but it is often useful to estimate the probabilities manually as a check on code functioning. The probability of failure of a given basic event is the probability that the basic event primary question fails to meet the performance metric for that question. The failure probability is related to how well the facility performs the task identified in that basic event over time (not just one performance or exercise). Fault tree calculations provide a failure probability for the top event in the fault tree. The basic fault tree calculations establish a baseline relative risk value for the system. This probability depicts relative risk, not absolute risk. Subsequent calculations are made to evaluate the change in relative risk that would occur if system performance is improved or degraded. During the development effort of MSET, the fault tree analysis program used was SAPHIRE. SAPHIRE is an acronym for 'Systems Analysis Programs for Hands-on Integrated Reliability Evaluations.' Version 1 of the SAPHIRE code was sponsored by the Nuclear Regulatory Commission in 1987 as an innovative way to draw, edit, and analyze graphical fault trees primarily for safe operation of nuclear power reactors. When the fault tree calculations are performed, the fault tree analysis program will produce several reports that can be used to analyze the MPC&A system. SAPHIRE produces reports showing risk importance factors for all basic events in the operational MC&A system. The risk importance information is used to examine the potential impacts when performance of certain basic events increases or decreases. The initial results produced by the SAPHIRE program are considered relative risk values. None of the results can be interpreted as absolute risk values since the basic event probability values represent estimates of risk associated with the performance of MPC&A tasks throughout the material balance area (MBA). The RRR for a basic event represents the decrease in total system risk that would result from improvement of that one event to a perfect performance level. Improvement of the basic event with the greatest RRR value produces a greater decrease in total system risk than improvement of any other basic event. Basic events with the greatest potential for system risk reduction are assigned performance improvement values, and new fault tree calculations show the improvement in total system risk. The operational impact or cost-effectiveness from implementing the performance improvements can then be evaluated. The improvements being evaluated can be system performance improvements, or they can be potential, or actual, upgrades to the system. The RIR for a basic event represents the increase in total system risk that would result from failure of that one event. Failure of the basic event with the greatest RIR value produces a greater increase in total system risk than failure of any other basic event. Basic events with the greatest potential for system risk increase are assigned failure performance values, and new fault tree calculations show the increase in total system risk. This evaluation shows the importance of preventing performance degradation of the basic events. SAPHIRE identifies combinations of basic events where concurrent failure of the events results in failure of the top event.« less
Jones, Jason J; Chu, Jeffrey; Graham, Jacob; Zaluski, Serge; Rocha, Guillermo
2016-01-01
The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%-12.0% (P<0.001 for data from Canada and the US and P<0.05 for data from France). Use of the preloaded delivery system also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity.
Parkhurst, R.S.; Christenson, S.C.
1987-01-01
Hydrochemical data were compiled into a data base as part of the Central Midwest Regional Aquifer System Analysis project. The data consist of chemical analyses of water samples collected from wells that are completed in formations of Mesozoic and Paleozoic age. The data base includes data from the National Water Data Storage and Retrieval System, the Petroleum Data System, the National Uranium Resource Evaluation, and selected publications. Chemical analyses were selected for inclusion within the hydrochemical data base if the total concentration of the cations differed from the total 10 percent or less of the total concentration of all ions. Those analyses which lacked the necessary data for an ionic balance were included if the ratios of dissolved-solids concentration to specific conductance were between 0.55 and 0.75. The tabulated chemical analyses, grouped by county, and a statistical summary of the analyses, listed by geologic unit, are presented.
Chandra, Suman; Khan, Shabana; Avula, Bharathi; Lata, Hemant; Yang, Min Hye; ElSohly, Mahmoud A.; Khan, Ikhlas A.
2014-01-01
A comparison of the product yield, total phenolics, total flavonoids, and antioxidant properties was done in different leafy vegetables/herbs (basil, chard, parsley, and red kale) and fruit crops (bell pepper, cherry tomatoes, cucumber, and squash) grown in aeroponic growing systems (AG) and in the field (FG). An average increase of about 19%, 8%, 65%, 21%, 53%, 35%, 7%, and 50% in the yield was recorded for basil, chard, red kale, parsley, bell pepper, cherry tomatoes, cucumber, and squash, respectively, when grown in aeroponic systems, compared to that grown in the soil. Antioxidant properties of AG and FG crops were evaluated using 2,2-diphenyl-1-picrylhydrazyl (DDPH) and cellular antioxidant (CAA) assays. In general, the study shows that the plants grown in the aeroponic system had a higher yield and comparable phenolics, flavonoids, and antioxidant properties as compared to those grown in the soil. PMID:24782905
Li, Lei; He, Qingming; Wei, Yunmei; He, Qin; Peng, Xuya
2014-11-01
To determine reliable state parameters which could be used as early warning indicators of process failure due to the acidification of anaerobic digestion of food waste, three mesophilic anaerobic digesters of food waste with different operation conditions were investigated. Such parameters as gas production, methane content, pH, concentrations of volatile fatty acid (VFA), alkalinity and their combined indicators were evaluated. Results revealed that operation conditions significantly affect the responses of parameters and thus the optimal early warning indicators of each reactor differ from each other. None of the single indicators was universally valid for all the systems. The universally valid indicators should combine several parameters to supply complementary information. A combination of total VFA, the ratio of VFA to total alkalinity (VFA/TA) and the ratio of bicarbonate alkalinity to total alkalinity (BA/TA) can reflect the metabolism of the digesting system and realize rapid and effective early warning. Copyright © 2014 Elsevier Ltd. All rights reserved.
Preliminary assessment of the velocity pump reaction turbine as a geothermal total-flow expander
NASA Astrophysics Data System (ADS)
Demuth, O. J.
1984-06-01
The velocity pump reaction turbine (VPRT) was evaluated as a total flow expander in a geothermal-electric conversion cycle. Values of geofluid effectiveness of VPRT systems were estimated for conditions consisting of: a 360(F) geothermal resource, 60 F wet-bulb ambient temperature, zero and 0.003 mass concentrations of dissolved noncondensible gas in the geofluid, 100 and 120 F condensing temperatures, and engine efficiencies ranging from 0.4 to 1.0. Achievable engine efficiencies were estimated to range from 0.77, with plant geofluid effectiveness values ranging as high as 9.5 watt hr-lbm geofluid for the 360 F resource temperature. This value is competitive with magnitudes of geofluid effectiveness projected for advanced binary plants, and is on the order of 40% higher than estimates for dual-flash steam and other total flow systems reviewed. Because of its potentially high performance and relative simplicity, the VPRT system appears to warrant further investigation toward its use in a well-head geothermal plant.
Small total dose measurement system for SDS-1
NASA Astrophysics Data System (ADS)
Kimoto, Yugo; Satoh, Yohei; Tachihara, Hiroshi
2009-11-01
The Japanese Aerospace Exploration Agency (JAXA) uses monitors on board satellites to measure and record in-flight data on ionization effects in space. A compact, total dose measurement system for the small satellite (SDS-1) was developed based on the previous system for measuring total ionizing dose effects. Especially, the sensor for SDS-1 is quite smaller than the sensor for SOHLA-1, which is presented in the last year. The sensor is 8 mm wide×3 mm high×19 mm long and weighs approximately 4 g with 500 mm its wire harness. Eight pin LCC RADFET and temperature sensor are arranged on it. Seven sensors are arranged on some components inside the SDS-1. One of the sensors is arranged on a printed board in advanced microprocessing in-ORBIT experiment equipment (AMI). The AMI demonstrate 320 MIPS microprocessor and DC-DC converter for space. The absorbed dose at the points where the sensors are arranged was evaluated before flight and will be compared with resulting flight data.
Evaluation of the Biolog automated microbial identification system
NASA Technical Reports Server (NTRS)
Klingler, J. M.; Stowe, R. P.; Obenhuber, D. C.; Groves, T. O.; Mishra, S. K.; Pierson, D. L.
1992-01-01
Biolog's identification system was used to identify 39 American Type Culture Collection reference taxa and 45 gram-negative isolates from water samples. Of the reference strains, 98% were identified to genus level and 76% to species level within 4 to 24 h. Identification of some authentic strains of Enterobacter, Klebsiella, and Serratia was unreliable. A total of 93% of the water isolates were identified.
ERIC Educational Resources Information Center
Southwest Educational Development Lab., Austin, TX.
This document reports on a program seen as an integral part of a total educational development plan for migrant children. The Early Childhood Education Learning System is an instructional program which includes staff development and parent-school-community involvement. Focus is on the special learning problems of Mexican-American children and the…
ERIC Educational Resources Information Center
Timonen-Soivio, Laura; Sourander, Andre; Malm, Heli; Hinkka-Yli-Salomäki, Susanna; Gissler, Mika; Brown, Alan; Vanhala, Raija
2015-01-01
The aim of this study was to evaluate the association between autism spectrum disorders (ASD) with and without intellectual disability (ID) and congenital anomalies (CAs) by organ system. The sample included all children diagnosed with ASD (n = 4441) from the Finnish Hospital Discharge Register during 1987-2000 and a total of four controls per…
Maristerra R. Lemes; Dario Grattapaglia; James Grogan; John Proctor; Rog& eacute Gribel; rio
2007-01-01
Microsatellites were used to evaluate the mating system of the remaining trees in a logged population of Swietenia macrophylla, a highly valuable and threatened hardwood species, in the Brazilian Amazon. A total of 25 open pollinated progeny arrays of 16 individuals, with their mother trees, were genotyped using eight highly polymorphic...
1998-04-01
selected is statistically based on the total number of faults and the failure rate distribution in the system under test. The fault set is also...implemented the BPM and system level emulation consolidation logic as well as statistics counters for cache misses and various bus transactions. These...instruction F22 Advanced Tactical Fighter FET Field Effect Transitor FF Flip-Flop FM Failures/Milhon hours C-3 FPGA Field Programmable Gate Array GET
USDA-ARS?s Scientific Manuscript database
Ewe productivity (i.e., total numbers or weight of lamb weaned ÷ number of breeding ewes) is a key indicator of lamb production efficiency. This second-generation study compared various measures of ewe productivity and ewe and lamb performance in an extensive rangeland production system of ewes of 3...
Usability in telemedicine systems-A literature survey.
Klaassen, B; van Beijnum, B J F; Hermens, H J
2016-09-01
The rapid development of sensors and communication technologies enable the growth of new innovative services in healthcare, such as Telemedicine. An essential ingredient in the development of a telemedicine system and its final acceptance by end users are usability studies. The principles of usability engineering, evaluations and telemedicine are well established, and it may contribute to the adoption and eventually deployment of such systems and services. An in-depth usability analysis, including performance and attitude measures, requires knowledge about available usability techniques, and is depending on the amount of resources. Therefore it is worth investigating how usability methods are applied in developing telemedicine systems. Our hypothesis is: with increasing research and development of telemedicine systems, we expect that various usability methods are more equally employed for different end-user groups and applications. A literature survey was conducted to find telemedicine systems that have been evaluated for usability or ease of use. The elements of the PICO framework were used as a basis for the selection criteria in the literature search. The search was not limited by year. Two independent reviewers screened all search results first by title, and then by abstract for inclusion. Articles were included up to May 2015. In total, 127 publications were included in this survey. The number of publications on telemedicine systems significantly increased after 2008. Older adults and end-users with cardiovascular conditions were among largest target end-user groups. Remote monitoring systems were found the most, in 90 publications. Questionnaires are the most common means for evaluating telemedicine systems, and were found in 88 publications. Questionnaires are used frequently in studies focusing on cardiovascular diseases, Parkinson's disease and older adult conditions. Interviews are found the most in publications related to stroke. In total 71% of the publications were trial-orientated and the remaining process orientated. An increase in telemedicine research, development and applications is found worldwide, with the majority of publications conducted in America. Monitoring patients in their homes can lead to better healthcare at lower costs which implies an increased demand of new healthcare strategies like telemedicine. We expected that with the increase in telemedicine research and development, a greater range of usability methods would also be employed in the included publications. This is not the case. Researchers employed questionnaires as a preferred usability method for each type of telemedicine system and most end-users. However, in process-orientated studies a greater range of usability evaluations were applied, with fewer differences found in the amount of publications for each evaluation method. Questionnaires enable researchers to evaluate a system quickly on end users, as it requires less expertise on the evaluation method compared to the other methods. They are easily distributed and are customizable. The use of questionnaires is therefore an evaluation method of choice for a variety of telemedicine systems and end-users. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Xie, Yan; Li, Mu; Zhou, Jin; Zheng, Chang-zheng
2009-07-01
Agricultural machinery total power is an important index to reflex and evaluate the level of agricultural mechanization. It is the power source of agricultural production, and is the main factors to enhance the comprehensive agricultural production capacity expand production scale and increase the income of the farmers. Its demand is affected by natural, economic, technological and social and other "grey" factors. Therefore, grey system theory can be used to analyze the development of agricultural machinery total power. A method based on genetic algorithm optimizing grey modeling process is introduced in this paper. This method makes full use of the advantages of the grey prediction model and characteristics of genetic algorithm to find global optimization. So the prediction model is more accurate. According to data from a province, the GM (1, 1) model for predicting agricultural machinery total power was given based on the grey system theories and genetic algorithm. The result indicates that the model can be used as agricultural machinery total power an effective tool for prediction.
Wilson, Sharon M; Prasan, Ananth M; Virdi, Amy; Lassere, Marissa; Ison, Glenn; Ramsay, David R; Weaver, James C
2016-10-10
The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.
Nondestructive evaluation technique guide
NASA Technical Reports Server (NTRS)
Vary, A.
1973-01-01
A total of 70 individual nondestructive evaluation (NDE) techniques are described. Information is presented that permits ease of comparison of the merits and limitations of each technique with respect to various NDE problems. An NDE technique classification system is presented. It is based on the system that was adopted by the National Materials Advisory Board (NMAB). The classification system presented follows the NMAB system closely with the exception of additional categories that have been added to cover more advanced techniques presently in use. The rationale of the technique is explained. The format provides for a concise description of each technique, the physical principles involved, objectives of interrogation, example applications, limitations of each technique, a schematic illustration, and key reference material. Cross-index tabulations are also provided so that particular NDE problems can be referred to appropriate techniques.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Xia; Hoffman, Forrest M.; Iversen, Colleen M.
Earth system models (ESMs) have been widely used for projecting global vegetation carbon dynamics, yet how well ESMs performed for simulating vegetation carbon density remains untested. Here we have compiled observational data of vegetation carbon density from literature and existing data sets to evaluate nine ESMs at site, biome, latitude, and global scales. Three variables—root (including fine and coarse roots), total vegetation carbon density, and the root:total vegetation carbon ratios (R/T ratios), were chosen for ESM evaluation. ESM models performed well in simulating the spatial distribution of carbon densities in root (r = 0.71) and total vegetation (r = 0.62).more » However, ESM models had significant biases in simulating absolute carbon densities in root and total vegetation biomass across the majority of land ecosystems, especially in tropical and arctic ecosystems. Particularly, ESMs significantly overestimated carbon density in root (183%) and total vegetation biomass (167%) in climate zones of 10°S–10°N. Substantial discrepancies between modeled and observed R/T ratios were found: the R/T ratios from ESMs were relatively constant, approximately 0.2 across all ecosystems, along latitudinal gradients, and in tropic, temperate, and arctic climatic zones, which was significantly different from the observed large variations in the R/T ratios (0.1–0.8). There were substantial inconsistencies between ESM-derived carbon density in root and total vegetation biomass and the R/T ratio at multiple scales, indicating urgent needs for model improvements on carbon allocation algorithms and more intensive field campaigns targeting carbon density in all key vegetation components.« less
Song, Xia; Hoffman, Forrest M.; Iversen, Colleen M.; ...
2017-09-09
Earth system models (ESMs) have been widely used for projecting global vegetation carbon dynamics, yet how well ESMs performed for simulating vegetation carbon density remains untested. Here we have compiled observational data of vegetation carbon density from literature and existing data sets to evaluate nine ESMs at site, biome, latitude, and global scales. Three variables—root (including fine and coarse roots), total vegetation carbon density, and the root:total vegetation carbon ratios (R/T ratios), were chosen for ESM evaluation. ESM models performed well in simulating the spatial distribution of carbon densities in root (r = 0.71) and total vegetation (r = 0.62).more » However, ESM models had significant biases in simulating absolute carbon densities in root and total vegetation biomass across the majority of land ecosystems, especially in tropical and arctic ecosystems. Particularly, ESMs significantly overestimated carbon density in root (183%) and total vegetation biomass (167%) in climate zones of 10°S–10°N. Substantial discrepancies between modeled and observed R/T ratios were found: the R/T ratios from ESMs were relatively constant, approximately 0.2 across all ecosystems, along latitudinal gradients, and in tropic, temperate, and arctic climatic zones, which was significantly different from the observed large variations in the R/T ratios (0.1–0.8). There were substantial inconsistencies between ESM-derived carbon density in root and total vegetation biomass and the R/T ratio at multiple scales, indicating urgent needs for model improvements on carbon allocation algorithms and more intensive field campaigns targeting carbon density in all key vegetation components.« less
NASA Technical Reports Server (NTRS)
Shipman, D. L.
1972-01-01
The development of a model to simulate the information system of a program management type of organization is reported. The model statistically determines the following parameters: type of messages, destinations, delivery durations, type processing, processing durations, communication channels, outgoing messages, and priorites. The total management information system of the program management organization is considered, including formal and informal information flows and both facilities and equipment. The model is written in General Purpose System Simulation 2 computer programming language for use on the Univac 1108, Executive 8 computer. The model is simulated on a daily basis and collects queue and resource utilization statistics for each decision point. The statistics are then used by management to evaluate proposed resource allocations, to evaluate proposed changes to the system, and to identify potential problem areas. The model employs both empirical and theoretical distributions which are adjusted to simulate the information flow being studied.
How to Analyze Verbal and Nonverbal Classroom Communication.
ERIC Educational Resources Information Center
Heger, Herbert K.
Based upon the communications process model of teaching and learning, the Miniaturized Total Interaction Analysis System (Mini-TIA) establishes a conceptual framework for observing symptomatic classroom behaviors. It provides a means for the evaluation of classroom communication. Interpersonal communication is defined as either verbal (using…
One of the most interesting stormwater control systems under evaluation by EPA are “green roofs”. Green roofs are vegetative covers applied to building roofs to slow, or totally absorb, rainfall runoff during storms. While the concept of over-planted roofs is very ancient, the go...
Baumann, Martin; Keinath, Andreas; Krems, Josef F; Bengler, Klaus
2004-05-01
Despite the usefulness of new on-board information systems one has to be concerned about the potential distraction effects that they impose on the driver. Therefore, methods and procedures are necessary to assess the visual demand that is connected to the usage of an on-board system. The occlusion-method is considered a strong candidate as a procedure for evaluating display designs with regard to their visual demand. This paper reports results from two experimental studies conducted to further evaluate this method. In the first study, performance in using an in-car navigation system was measured under three conditions: static (parking lot), occlusion (shutter glasses), and driving. The results show that the occlusion-procedure can be used to simulate visual requirements of real traffic conditions. In a second study the occlusion method was compared to a global evaluation criterion based on the total task time. It can be demonstrated that the occlusion method can identify tasks which meet this criterion, but are yet irresolvable under driving conditions. It is concluded that the occlusion technique seems to be a reliable and valid method for evaluating visual and dialogue aspects of in-car information systems.
Mbuthia, Jackson Mwenda; Rewe, Thomas Odiwuor; Kahi, Alexander Kigunzu
2015-02-01
This study evaluated pig production practices by smallholder farmers in two distinct production systems geared towards addressing their constraints and prospects for improvement. The production systems evaluated were semi-intensive and extensive and differed in remoteness, market access, resource availability and pig production intensity. Data were collected using structured questionnaires where a total of 102 pig farmers were interviewed. Qualitative and quantitative research methods were employed to define the socioeconomic characteristics of the production systems, understanding the different roles that pigs play, marketing systems and constraints to production. In both systems, regular cash income and insurance against emergencies were ranked as the main reasons for rearing pigs. Marketing of pigs was mainly driven by the type of production operation. Finances, feeds and housing were identified as the major constraints to production. The study provides important parameters and identifies constraints important for consideration in design of sustainable production improvement strategies. Feeding challenges can be improved through understanding the composition and proper utilization of local feed resources. Provision of adequate housing would improve the stocking rates and control mating.
Ross, Elliot M; Harper, Stephen A; Cunningham, Cord; Walrath, Benjamin D; DeMers, Gerard; Kharod, Chetan U
2017-03-01
As part of a Military Emergency Medical Services (EMS) system process improvement initiative, the authors sought to objectively evaluate the U.S. military EMS system for the island of Okinawa. They applied a program evaluation tool currently utilized by the U.S. National Park Service (NPS). A comprehensive needs assessment was conducted to evaluate the current Military EMS system in Okinawa, Japan. The NPS EMS Program Audit Worksheet was used to get an overall "score" of our assessment. After all the data had been collected, a joint committee of Military EMS physicians reviewed the findings and made formal recommendations. From 2011 to 2014, U.S. military EMS on Okinawa averaged 1,345 ± 137 patient transports annually. An advanced life support (ALS) provider would have been dispatched on 558 EMS runs (38%) based on chief complaint in 2014 had they been available. Over 36,000 man-hours were expended during this period to provide National Registry Emergency Medical Technician (EMT)-accredited instruction to certify 141 Navy Corpsman as EMT Basics. The NPS EMS Program Audit Worksheet was used and the program scored a total of 31, suggesting the program is well planned and operating within standards. This evaluation of the Military EMS system on Okinawa using the NPS program assessment and audit worksheet demonstrates the NPS evaluation instruments may offer a useful assessment tool for the evaluation of Military EMS systems. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
Surfing for mouth guards: assessing quality of online information.
Magunacelaya, Macarena B; Glendor, Ulf
2011-10-01
The Internet is an easily accessible and commonly used source of health-related information, but evaluations of the quality of this information within the dental trauma field are still lacking. The aims of this study are (i) to present the most current scientific knowledge regarding mouth guards used in sport activities, (ii) to suggest a scoring system to evaluate the quality of information pertaining to mouth guard protection related to World Wide Web sites and (iii) to employ this scoring system when seeking reliable mouth guard-related websites. First, an Internet search using the keywords 'athletic injuries/prevention and control' and 'mouth protector' or 'mouth guards' in English was performed on PubMed, Cochrane, SvedMed+ and Web of Science to identify scientific knowledge about mouth guards. Second, an Internet search using the keywords 'consumer health information Internet', 'Internet information public health' and 'web usage-seeking behaviour' was performed on PubMed and Web of Science to obtain scientific articles seeking to evaluate the quality of health information on the Web. Based on the articles found in the second search, two scoring systems were selected. Then, an Internet search using the keywords 'mouth protector', 'mouth guards' and 'gum shields' in English was performed on the search engines Google, MSN and Yahoo. The websites selected were evaluated for reliability and accuracy. Of the 223 websites retrieved, 39 were designated valid and evaluated. Nine sites scored 22 or higher. The mean total score of the 39 websites was 14.2. Fourteen websites scored higher than the mean total score, and 25 websites scored less. The highest total score, presented by a Public Institution Web site (Health Canada), was 31 from a maximum possible score of 34, and the lowest score was 0. This study shows that there is a high amount of information about mouth guards on the Internet but that the quality of this information varies. It should be the responsibility of health care professionals to suggest and provide reliable Internet URL addresses to patients. In addition, an appropriate search terminology and search strategy should be made available to persons who want to search beyond the recommended sites. © 2011 John Wiley & Sons A/S.
Evaluation of the Dacos 3.0 analyser.
Pons, J F; Alumá, A; Antoja, F; Biosca, C; Alsina, M J; Galimany, R
1990-01-01
The selective multitest Coulter Dacos 3.0 analyser was evaluated according to the guidelines of the Comisión de Instrumentación de la Sociedad Española de Química Clínica and of the European Committee for Clinical Laboratory Standards.THE EVALUATION WAS PERFORMED IN FOUR STEPS: examination of the analytical units; evaluation of routine working; study of interferences; and assessment of practicability.The evaluation included a photometric study. The inaccuracy is acceptable for 340 nm and 420 nm, and the imprecision at absorbances from 0.05 to 2.00 ranged from 0.06 to 0.28% at 340 nm and from 0.06 to 0.08% at 420 nm. The linearity showed some dispersion at low absorbance for PNP at 420 nm and the drift was negligible.The imprecision of the pipette delivery system, the temperature control system and the washing system were satisfactory.IN ROUTINE WORK CONDITIONS, SEVEN ANALYTICAL METHODS WERE STUDIED: glucose, creatinine, iron, total protein, AST, ALP and calcium. Within-run imprecision ranged, at low concentrations, from 0.9% (CV) for glucose, to 7.6% (CV) for iron; at medium concentrations, from 0.7% (CV) for total protein to 5.2% (CV) to creatinine; and at high concentrations, it ranged from 0.6% (CV) for glucose to 3.9% (CV) for ALP.Between-run imprecision at low concentrations ranged from 1.4% (CV) for glucose to 15.1% (CV) for iron; at medium concentrations it ranged from 1.2% (CV) for protein to 6.7% (CV) for iron; and at high concentrations the range is from l.2for AST to 5.7% (CV) for iron.No contamination was found in the sample carry-over study. Some contamination was found in the reagent carry-over study (total protein due to iron and calcium reagents). Relative inaccuracy is good for all the constituents assayed. Only LDH (high and low levels) and urate (low level) showed weak and negative interference caused by turbidity, and gamma-GT (high level) and amylase, bilirubin and ALP (two levels) showed a negative interference caused by haemolysis.
Evanescent Field Based Photoacoustics: Optical Property Evaluation at Surfaces
Goldschmidt, Benjamin S.; Rudy, Anna M.; Nowak, Charissa A.; Tsay, Yowting; Whiteside, Paul J. D.; Hunt, Heather K.
2016-01-01
Here, we present a protocol to estimate material and surface optical properties using the photoacoustic effect combined with total internal reflection. Optical property evaluation of thin films and the surfaces of bulk materials is an important step in understanding new optical material systems and their applications. The method presented can estimate thickness, refractive index, and use absorptive properties of materials for detection. This metrology system uses evanescent field-based photoacoustics (EFPA), a field of research based upon the interaction of an evanescent field with the photoacoustic effect. This interaction and its resulting family of techniques allow the technique to probe optical properties within a few hundred nanometers of the sample surface. This optical near field allows for the highly accurate estimation of material properties on the same scale as the field itself such as refractive index and film thickness. With the use of EFPA and its sub techniques such as total internal reflection photoacoustic spectroscopy (TIRPAS) and optical tunneling photoacoustic spectroscopy (OTPAS), it is possible to evaluate a material at the nanoscale in a consolidated instrument without the need for many instruments and experiments that may be cost prohibitive. PMID:27500652
Pinheiro, Alexandre M; Santos, Cláudia Valle; Costa, Maria de Fátima D; Rodrigues, Luiz Erlon A
2007-08-01
Neospora caninum is a protozoon that causes abortion in cattle and neuromuscular lesions in dogs, with the formation of cysts mainly in the central nervous system. Since N. caninum is an intracellular parasite with tropism for the cells of nervous system, this study evaluated the respiratory metabolism of glial cells infected by this* parasite. Glial cultures obtained from the cerebral cortex of newborn rats were kept in DMEM enriched with 10% fetal bovine serum, 1 mM pyruvic acid and 2 mM of L-glutamine. They were infected at a ratio of approximately 1:1 (cell/parasite). Oxygen consumption was evaluated by polarography in the non infected and N. caninum infected groups, 24 and 72 h following infection. Glial cell respiration after 24 and 72 h was 307.2 +/- 34.7 and 308.9 +/- 64.1 microL of oxygen per mug of total protein per minute, and 566.2 +/- 54.6 and 579 +/- 117.5 microL O2/microg of total protein/minute in the control and infected groups, respectively. These results show that N. caninum does not interfere with glial respiration in vitro.
Development of the prototype pneumatic transfer system for ITER neutron activation system.
Cheon, M S; Seon, C R; Pak, S; Lee, H G; Bertalot, L
2012-10-01
The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.
NASA Technical Reports Server (NTRS)
1981-01-01
Reasonable space systems concepts were systematically identified and defined and a total system was evaluated for the space disposal of nuclear wastes. Areas studied include space destinations, space transportation options, launch site options payload protection approaches, and payload rescue techniques. Systems level cost and performance trades defined four alternative space systems which deliver payloads to the selected 0.85 AU heliocentric orbit destination at least as economically as the reference system without requiring removal of the protective radiation shield container. No concepts significantly less costly than the reference concept were identified.
Hydrodynamic description of an unmagnetized plasma with multiple ion species. I. General formulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simakov, Andrei N., E-mail: simakov@lanl.gov; Molvig, Kim
2016-03-15
A generalization of the Braginskii ion fluid description [S. I. Braginskii, Sov. Phys. - JETP 6, 358 (1958)] to the case of an unmagnetized collisional plasma with multiple ion species is presented. An asymptotic expansion in the ion Knudsen number is used to derive the individual ion species continuity, as well as the total ion mass density, momentum, and energy evolution equations accurate through the second order. Expressions for the individual ion species drift velocities with respect to the center of mass reference frame, as well as for the total ion heat flux and viscosity, which are required to closemore » the fluid equations, are evaluated in terms of the first-order corrections to the lowest order Maxwellian ion velocity distribution functions. A variational formulation for evaluating such corrections and its relation to the plasma entropy are presented. Employing trial functions for the corrections, written in terms of expansions in generalized Laguerre polynomials, and maximizing the resulting functionals produce two systems of linear equations (for “vector” and “tensor” portions of the corrections) for the expansion coefficients. A general matrix formulation of the linear systems as well as expressions for the resulting transport fluxes are presented in forms convenient for numerical implementation. The general formulation is employed in Paper II [A. N. Simakov and K. Molvig, Phys. Plasmas 23, 032116 (2016)] to evaluate the individual ion drift velocities and the total ion heat flux and viscosity for specific cases of two and three ion species plasmas.« less
Are university rankings useful to improve research? A systematic review
Momani, Shaher
2018-01-01
Introduction Concerns about reproducibility and impact of research urge improvement initiatives. Current university ranking systems evaluate and compare universities on measures of academic and research performance. Although often useful for marketing purposes, the value of ranking systems when examining quality and outcomes is unclear. The purpose of this study was to evaluate usefulness of ranking systems and identify opportunities to support research quality and performance improvement. Methods A systematic review of university ranking systems was conducted to investigate research performance and academic quality measures. Eligibility requirements included: inclusion of at least 100 doctoral granting institutions, be currently produced on an ongoing basis and include both global and US universities, publish rank calculation methodology in English and independently calculate ranks. Ranking systems must also include some measures of research outcomes. Indicators were abstracted and contrasted with basic quality improvement requirements. Exploration of aggregation methods, validity of research and academic quality indicators, and suitability for quality improvement within ranking systems were also conducted. Results A total of 24 ranking systems were identified and 13 eligible ranking systems were evaluated. Six of the 13 rankings are 100% focused on research performance. For those reporting weighting, 76% of the total ranks are attributed to research indicators, with 24% attributed to academic or teaching quality. Seven systems rely on reputation surveys and/or faculty and alumni awards. Rankings influence academic choice yet research performance measures are the most weighted indicators. There are no generally accepted academic quality indicators in ranking systems. Discussion No single ranking system provides a comprehensive evaluation of research and academic quality. Utilizing a combined approach of the Leiden, Thomson Reuters Most Innovative Universities, and the SCImago ranking systems may provide institutions with a more effective feedback for research improvement. Rankings which extensively rely on subjective reputation and “luxury” indicators, such as award winning faculty or alumni who are high ranking executives, are not well suited for academic or research performance improvement initiatives. Future efforts should better explore measurement of the university research performance through comprehensive and standardized indicators. This paper could serve as a general literature citation when one or more of university ranking systems are used in efforts to improve academic prominence and research performance. PMID:29513762
Preliminary Results on Design and Implementation of a Solar Radiation Monitoring System
Balan, Mugur C.; Damian, Mihai; Jäntschi, Lorentz
2008-01-01
The paper presents a solar radiation monitoring system, using two scientific pyranometers and an on-line computer home-made data acquisition system. The first pyranometer measures the global solar radiation and the other one, which is shaded, measure the diffuse radiation. The values of total and diffuse solar radiation are continuously stored into a database on a server. Original software was created for data acquisition and interrogation of the created system. The server application acquires the data from pyranometers and stores it into a database with a baud rate of one record at 50 seconds. The client-server application queries the database and provides descriptive statistics. A web interface allow to any user to define the including criteria and to obtain the results. In terms of results, the system is able to provide direct, diffuse and total radiation intensities as time series. Our client-server application computes also derivate heats. The ability of the system to evaluate the local solar energy potential is highlighted. PMID:27879746
Low cost miniature data collection platform
NASA Technical Reports Server (NTRS)
1977-01-01
The development of the RF elements of a telecommunications package involved detailed study and analysis of concepts and techniques followed by laboratory testing and evaluation of designs. The design goals for a complete telecommunications package excluding antenna were a total weight of 300 grams, in a total volume of 400 cu cm with a capability of unattended operation for a period of six months. Of utmost importance is extremely low cost when produced in lots of 10,000. Early in the program it became apparent that a single Miniature Data Collection Platform would not satisfy all users. A single high efficiency system would not satisfy a user who had available a large battery capacity but required a low cost system. Conversely, the low cost system would not satisfy the end user who had a very limited battery capacity. A system design to satisfy these varied requirements was implemented by designing several versions of the system building blocks and then constructing three systems from these building blocks.
Improvement in the stability of serum samples stored in an automated refrigerated module.
Parra-Robert, Marina; Rico-Santana, Naira; Alcaraz-Quiles, José; Sandalinas, Silvia; Fernández, Esther; Falcón, Isabel; Pérez-Riedweg, Margarita; Bedini, Josep Lluís
2016-12-01
In clinical laboratories it is necessary to know for how long the analytes are stable in the samples with specific storage conditions. Our laboratory has implemented the new Aptio Automation System (AAS) (Siemens Healthcare Diagnostics) where the analyzed samples are stored in a refrigerated storage module (RSM) after being sealed. The aim of the study was to evaluate the stability of serum samples with the AAS and comparing the results with a previous study using a conventional refrigerated system. Serum samples from a total of 50 patients were collected and for each of them 27 biochemical analytes were analyzed. The samples were divided in 5 sets of 10 samples. Each set was re-analyzed at one of the following times: 24, 48, 72, 96 and 120h. Stability was evaluated according to the Total Limit of Change (TLC) criteria, which combine both analytical and biologic variation. A total of 26 out of 27 analytes were stable at the end of the study according to TLC criteria. Lactate dehydrogenase was not stable at 48h observing a decrease in its concentration until the end of the study. In the previous study (conventional storage system) 9 biochemical analytes were not stable with an increase of their levels due to the evaporation process. The RSM connected to the AAS improves the stability of serum samples. This system avoids the evaporation process due to the sealing of samples and allows better control of the samples during their storage. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Evaluation of exposure to airborne heavy metals at gun shooting ranges.
Lach, Karel; Steer, Brian; Gorbunov, Boris; Mička, Vladimír; Muir, Robert B
2015-04-01
Aerosols formed during shooting events were studied with various techniques including the wide range size resolving sampling system Nano-ID(®) Select, followed by inductively coupled plasma mass spectrometry chemical analysis, scanning electron microscopy, and fast mobility particle sizing. The total lead mass aerosol concentration ranged from 2.2 to 72 µg m(-3). It was shown that the mass concentration of the most toxic compound lead is much lower than the total mass concentration. The deposition fraction in various compartments of the respiratory system was calculated using the ICRP lung deposition model. It was found that the deposition fraction in the alveolar range varies by a factor >3 for the various aerosols collected, depending on the aerosol size distribution and total aerosol concentration, demonstrating the importance of size resolved sampling in health risk evaluation. The proportion of the total mass of airborne particles deposited in the respiratory tract varies from 34 to 70%, with a median of 55.9%, suggesting the health risk based upon total mass significantly overestimates the accumulated dose and therefore the health risk. A comparison between conventional and so called 'green' ammunition confirmed significant lowering of concentrations of lead and other toxic metals like antimony in the atmosphere of indoor shooting ranges using 'green' ammunition, although higher concentrations of manganese and boron were measured. These metals are likely to be the constituents of new types of primers. They occur predominantly in the size fraction <250 nm of aerosols. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Innovative Design Systems: Where Are We, and Where Do We Go from Here
1990-01-12
Description of a Tap U Figure 4- 5 : Causal Explanation of the Tap Function 12 Figre 4- 6 : The configuration space and qualitative 13 states of a tap Figure 4...Cunrniy, syntactic relaxations are most widely used. For example the constraint "Total Delay <- 5 hours" could be changed to: "Total delay <- 6 ...alternatives by way of ideas 5 . Incubation: Letting up, to invite illumination 6 . Synthesis: Putting the pieces together 7. Evaluation: Judging the
Performance of an Anaerobic Baffled Reactor (ABR) in treatment of cassava wastewater
Ferraz, Fernanda M.; Bruni, Aline T.; Del Bianchi, Vanildo L.
2009-01-01
The performance of an anaerobic baffled reactor (ABR) was evaluated in the treatment of cassava wastewater, a pollutant residue. An ABR divided in four equal volume compartments (total volume 4L) and operated at 35ºC was used in cassava wastewater treatment. Feed tank chemical oxygen demand (COD) was varied from 2000 to 7000 mg L-1 and it was evaluated the most appropriated hydraulic retention time (HRT) for the best performance on COD removal. The ABR was evaluated by analysis of COD (colorimetric method), pH, turbidity, total and volatile solids, alkalinity and acidity. Principal component analysis (PCA) was carried to better understand data obtained. The system showed buffering ability as acidity decreased along compartments while alkalinity and pH values were increased. There was particulate material retention and COD removal varied from 83 to 92% for HRT of 3.5 days. PMID:24031316
Gao, Qi; Zhou, Min; Han, Chengyin; Li, Shangyan; Zhang, Shuang; Yao, Yuan; Li, Bo; Qiao, Hao; Ai, Di; Lou, Ge; Zhang, Mengya; Jiang, Yanyi; Bi, Zhiyi; Ma, Longsheng; Xu, Xinye
2018-05-22
Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1 S 0 - 3 P 0 transition of neutral 171 Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171 Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10 -17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10 -16 . The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.
Evaluation of food drying with air dehumidification system: a short review
NASA Astrophysics Data System (ADS)
Djaeni, M.; Utari, F. D.; Sasongko, S. B.; Kumoro, A. C.
2018-01-01
Energy efficient drying for food and agriculture products resulting high quality products has been an important issue. Currently, about 50% of total energy for postharvest treatment was used for drying. This paper presents the evaluation of new approach namely air dehumidification system with zeolite for food drying. Zeolite is a material having affinity to water in which reduced the moisture in air. With low moisture content and relative humidity, the air can improve driving force for drying even at low temperature. Thus, the energy efficiency can be potentially enhanced and the product quality can be well retained. For proving the hypothesis, the paddy and onion have been dried using dehumidified air. As performance indicators, the drying time, product quality, and heat efficiency were evaluated. Results indicated that the drying with zeolite improved the performances significantly. At operating temperature ranging 50 - 60°C, the efficiency of drying system can reach 75% with reasonable product quality.
Evaluation of ovarian reserve tests in women with systemic lupus erythematosus.
Ulug, Pasa; Oner, Gokalp; Kasap, Burcu; Akbas, Emin Murat; Ozcicek, Fatih
2014-07-01
Impact of systemic lupus erythematosus (SLE) on fertility may be negative, and ovarian function can be also reduced by autoimmune oophoritis. In this article, we evaluated the ovarian reserve of pre-menopausal women firstly diagnosed with systemic lupus erythematosus (SLE). This was a prospective controlled study which included twenty women with SLE and twenty healthy women as controls in the reproductive age. Basal levels of FSH, estradiol (E2), and LH on cycle day 3 were measured. All participants underwent transvaginal ultrasonographic examination on the third day of their menstrual periods for the determination of ovarian volume (OV) and total antral follicle count (AFC). A significant difference in FSH, LH, and E2 levels was observed between women with SLE and healthy controls. There was a statistically significant reduction in total AFC and OV in SLE group. Age was associated negatively with AFC, whereas positively with FSH and LH. Menstrual irregularity was significantly higher in SLE patients than control. AFC was the most reliable test to show the menstrual irregularity and negatively correlated each other in women with SLE. In this preliminary study, the first in SLE patients, we illustrated that women with SLE had lower ovarian reserves and higher menstrual irregularity compared with healthy controls according to hormonal and ultrasonographical evaluation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Qian, Xiaoyong; Shen, Genxiang; Wang, Zhenqi; Guo, Chunxia; Liu, Yangqing; Lei, Zhongfang; Zhang, Zhenya
2014-02-01
Composting is considered to be a primary treatment method for livestock manure and rice straw, and high degree of maturity is a prerequisite for safe land application of the composting products. In this study pilot-scale experiments were carried out to characterize the co-composting process of livestock manure with rice straw, as well as to establish a maturity evaluation index system for the composts obtained. Two pilot composting piles with different feedstocks were conducted for 3 months: (1) swine manure and rice straw (SM-RS); and (2) dairy manure and rice straw (DM-RS). During the composting process, parameters including temperature, moisture, pH, total organic carbon (TOC), organic matter (OM), different forms of nitrogen (total, ammonia and nitrate), and humification index (humic acid and fulvic acid) were monitored in addition to germination index (GI), plant growth index (PGI) and Solvita maturity index. OM loss followed the first-order kinetic model in both piles, and a slightly faster OM mineralization was achieved in the SM-RS pile. Also, the SM-RS pile exhibited slightly better performance than the DM-RS according to the evolutions of temperature, OM degradation, GI and PGI. The C/N ratio, GI and PGI could be included in the maturity evaluation index system in which GI>120% and PGI>1.00 signal mature co-composts. Copyright © 2013 Elsevier Ltd. All rights reserved.
Barrera-Díaz, Carlos E; Frontana-Uribe, Bernardo A; Roa-Morales, Gabriela; Bilyeu, Bryan W
2015-01-01
The objective of this study was to evaluate the effect of copper electrocoagulation and hydrogen peroxide on COD, color, turbidity, and bacterial activity in a mixed industry wastewater. The integrated system of copper electrocoagulation and hydrogen peroxide is effective at reducing the organic and bacterial content of industrial wastewater. The copper electrocoagulation alone reduces COD by 56% in 30 min at pH 2.8, but the combined system reduces COD by 78%, biochemical oxygen demand (BOD5) by 81%, and color by 97% under the same conditions. Colloidal particles are flocculated effectively, as shown by the reduction of zeta potential and the 84% reduction in turbidity and 99% reduction in total solids. Additionally, the total coliforms, fecal coliforms, and bacteria are all reduced by 99%. The integrated system is effective and practical for the reduction of both organic and bacterial content in industrial wastewater.
Stochastic modeling of total suspended solids (TSS) in urban areas during rain events.
Rossi, Luca; Krejci, Vladimir; Rauch, Wolfgang; Kreikenbaum, Simon; Fankhauser, Rolf; Gujer, Willi
2005-10-01
The load of total suspended solids (TSS) is one of the most important parameters for evaluating wet-weather pollution in urban sanitation systems. In fact, pollutants such as heavy metals, polycyclic aromatic hydrocarbons (PAHs), phosphorous and organic compounds are adsorbed onto these particles so that a high TSS load indicates the potential impact on the receiving waters. In this paper, a stochastic model is proposed to estimate the TSS load and its dynamics during rain events. Information on the various simulated processes was extracted from different studies of TSS in urban areas. The model thus predicts the probability of TSS loads arising from combined sewer overflows (CSOs) in combined sewer systems as well as from stormwater in separate sewer systems in addition to the amount of TSS retained in treatment devices in both sewer systems. The results of this TSS model illustrate the potential of the stochastic modeling approach for assessing environmental problems.
"Living off the land": resource efficiency of wetland wastewater treatment.
Nelson, M; Odum, H T; Brown, M T; Alling, A
2001-01-01
Bioregenerative life support technologies for space application are advantageous if they can be constructed using locally available materials, and rely on renewable energy resources, lessening the need for launch and resupply of materials. These same characteristics are desirable in the global Earth environment because such technologies are more affordable by developing countries, and are more sustainable long-term since they utilize less non-renewable, imported resources. Subsurface flow wetlands (wastewater gardens(TM)) were developed and evaluated for wastewater recycling along the coast of Yucatan. Emergy evaluations, a measure of the environmental and human economic resource utilization, showed that compared to conventional sewage treatment, wetland wastewater treatment systems use far less imported and purchased materials. Wetland systems are also less energy-dependent, lessening dependence on electrical infrastructure, and require simpler maintenance since the system largely relies on the ecological action of microbes and plants for their efficacy. Detailed emergy evaluations showed that wetland systems use only about 15% the purchased emergy of conventional sewage systems, and that renewable resources contribute 60% of total emergy used (excluding the sewage itself) compared to less than 1% use of renewable resources in the high-tech systems. Applied on a larger scale for development in third world countries, wetland systems would require the electrical energy of conventional sewage treatment (package plants), and save of total capital and operating expenses over a 20-year timeframe. In addition, there are numerous secondary benefits from wetland systems including fiber/fodder/food from the wetland plants, creation of ecosystems of high biodiversity with animal habitat value, and aesthestic/landscape enhancement of the community. Wetland wastewater treatment is an exemplar of ecological engineering in that it creates an interface ecosystem to handle byproducts of the human economy, maximizing performance of the both the natural economy and natural ecosystems. Wetland systems accomplish this with far greater resource economy than other sewage treatment approaches, and thus offer benefits for both space and Earth applications. c 2001. COSPAR. Published by Elsevier Science Ltd. All rights reserved.
``Living off the land'': resource efficiency of wetland wastewater treatment
NASA Astrophysics Data System (ADS)
Nelson, M.; Odum, H. T.; Brown, M. T.; Alling, A.
Bioregenerative life support technologies for space application are advantageous if they can be constructed using locally available materials, and rely on renewable energy resources, lessening the need for launch and resupply of materials. These same characteristics are desirable in the global Earth environment because such technologies are more affordable by developing countries, and are more sustainable long-term since they utilize less non-renewable, imported resources. Subsurface flow wetlands (wastewater gardens™) were developed and evaluated for wastewater recycling along the coast of Yucatan. Emergy evaluations, a measure of the environmental and human economic resource utilization, showed that compared to conventional sewage treatment, wetland wastewater treatment systems use far less imported and purchased materials. Wetland systems are also less energy-dependent, lessening dependence on electrical infrastructure, and require simpler maintenance since the system largely relies on the ecological action of microbes and plants for their efficacy. Detailed emergy evaluations showed that wetland systems use only about 15% the purchased emergy of conventional sewage systems, and that renewable resources contribute 60% of total emergy used (excluding the sewage itself) compared to less than 1% use of renewable resources in the high-tech systems. Applied on a larger scale for development in third world countries, wetland systems would require 1/5 the electrical energy of conventional sewage treatment (package plants), and save 2/3 of total capital and operating expenses over a 20-year timeframe. In addition, there are numerous secondary benefits from wetland systems including fiber/fodder/food from the wetland plants, creation of ecosystems of high biodiversity with animal habitat value, and aesthestic/landscape enhancement of the community. Wetland wastewater treatment is an exemplar of ecological engineering in that it creates an interface ecosystem to handle byproducts of the human economy, maximizing performance of the both the natural economy and natural ecosystems. Wetland systems accomplish this with far greater resource economy than other sewage treatment approaches, and thus offer benefits for both space and Earth applications.
Idemoto, Yoshiaki; Miura, Shin-Ichiro; Norimatsu, Kenji; Suematsu, Yasunori; Hitaka, Yuka; Shiga, Yuhei; Morii, Joji; Imaizumi, Satoshi; Kuwano, Takashi; Iwata, Atsushi; Zhang, Bo; Ogawa, Masahiro; Saku, Keijiro
2017-03-01
The Total Thrombus-formation Analysis System (T-TAS ® ) is a novel automated microchip flow-chamber system for the quantitative evaluation of thrombus formation under blood flow conditions. T-TAS ® uses two types of microchip to evaluate thrombus formation: the AR-chip quantifies white thrombus formation and the PL-chip quantifies platelet thrombus formation. We assessed the antithrombotic abilities of various non-vitamin K antagonist oral anticoagulants (NOACs) using T-TAS ® . One hundred and three consecutive patients who were hospitalized with cardiovascular diseases were enrolled. We divided the patients into 2 groups; a control group that did not receive an anticoagulant (non-AC group) and an anticoagulant group (AC group). The AC group was further divided into warfarin, dabigatran, rivaroxaban and apixaban groups. We performed common coagulation tests and evaluated the area under the flow pressure curve (AR-AUC and PL-AUC) to quantify antithrombotic ability using T-TAS ® at the trough. There were no significant differences in patient characteristics between the non-AC and AC groups. Only 55.1 % of patients in the AC group achieved the target blood pressure (BP) of less than 130/80 mmHg. Compared with the non-AC group, AR-AUC was significantly decreased in the AC, warfarin, dabigatran and apixaban groups. Only the rivaroxaban group did not show a significant decrease in AR-AUC. NOACs showed a significant decrease in PL-AUC compared with the non-AC group. In conclusion, T-TAS ® was a useful tool for evaluating anticoagulation activity. NOACs was significantly effective as an antiplatelet agent. BP control should be a higher priority than the selection of an anticoagulant drug, especially NOACs.
Sapag, Jaime C; Rush, Brian; Ferris, Lorraine E
2016-02-01
This study examined Latin American evaluation needs regarding the development of a collaborative mental health care (CMHC) evaluation framework as seen by local key health-care leaders and professionals. Potential implementation challenges and opportunities were also identified. This multisite research study used an embedded mixed methods approach in three public health networks in Mexico, Nicaragua and Chile. Local stakeholders participated: decision-makers in key informant interviews, front-line clinicians in focus groups and other stakeholders through a survey. The analysis was conducted within site and then across sites. A total of 22 semi-structured interviews, three focus groups and 27 questionnaires (52% response rate) were conducted. Participants recognized a strong need to evaluate different areas of CMHC in Latin America, including access, types and quality of services, human resources and outcomes related to mental disorders, including addiction. A priority was to evaluate collaboration within the health system, including the referral system. Issues of feasibility, including the weaknesses of information systems, were also identified. Local stakeholders strongly supported the development of a comprehensive evaluation framework for CMHC in Latin America and cited several dimensions and contextual factors critical for inclusion. Implementation must allow flexibility and adaptation to the local context. © 2015 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Bradley, E. S.; Little, B. H.; Warnock, W.; Jenness, C. M.; Wilson, J. M.; Powell, C. W.; Shoaf, L.
1982-01-01
The establishment of propfan technology readiness was determined and candidate drive systems for propfan application were identified. Candidate testbed aircraft were investigated for testbed aircraft suitability and four aircraft selected as possible propfan testbed vehicles. An evaluation of the four candidates was performed and the Boeing KC-135A and the Gulfstream American Gulfstream II recommended as the most suitable aircraft for test application. Conceptual designs of the two recommended aircraft were performed and cost and schedule data for the entire testbed program were generated. The program total cost was estimated and a wind tunnel program cost and schedule is generated in support of the testbed program.
Fiber optic control system integration
NASA Technical Reports Server (NTRS)
Poppel, G. L.; Glasheen, W. M.; Russell, J. C.
1987-01-01
A total fiber optic, integrated propulsion/flight control system concept for advanced fighter aircraft is presented. Fiber optic technology pertaining to this system is identified and evaluated for application readiness. A fiber optic sensor vendor survey was completed, and the results are reported. The advantages of centralized/direct architecture are reviewed, and the concept of the protocol branch is explained. Preliminary protocol branch selections are made based on the F-18/F404 application. Concepts for new optical tools are described. Development plans for the optical technology and the described system are included.
Performance simulation for the design of solar heating and cooling systems
NASA Technical Reports Server (NTRS)
Mccormick, P. O.
1975-01-01
Suitable approaches for evaluating the performance and the cost of a solar heating and cooling system are considered, taking into account the value of a computer simulation concerning the entire system in connection with the large number of parameters involved. Operational relations concerning the collector efficiency in the case of a new improved collector and a reference collector are presented in a graph. Total costs for solar and conventional heating, ventilation, and air conditioning systems as a function of time are shown in another graph.
He, Cheng; Li, Wei; Zhang, Jian-Jun; Qu, Sheng-Sheng; Li, Jia-Jing; Wang, Lin-Yuan
2014-12-01
In order to establish a method for the determination of the sterols of the oil in the freeze-dried acai (Euterpe oleracea Mart.) and to evaluate its antioxidant activities, a saponification/extraction procedure and high performance liquid chromatography (HPLC) analysis method were developed and validated for the analysis of phytosterols in PEE (Petroleum ether extract). Separation was achieved on a Purosper STAR LP C18 column with a binary, gradient solvent system of acetonitrile and isopropanol. Evaporative light scattering detection (ELSD) was used to quantify β-sitosterol and the total sterols. Peak identification was verified by retention times and spikes with external standards. Standard curves were constructed (r = 0.999 2) to allow for sample quantification. Recovery of the saponification and extraction was demonstrated via analysis of spiked samples. The highest content of total sterols is β-sitosterol. The antioxidant activities of the extracts were evaluated using the total oxyradical scavenging capacity assay (TOSC assay). The result showed that the PEE exhibited significant antioxidant properties, sample concentration and the antioxidant capacity had a certain relevance.
Forooghian, Farzin; Cukras, Catherine; Meyerle, Catherine B; Chew, Emily Y; Wong, Wai T
2008-10-01
To evaluate macular thickness and volume measurements and their intrasession repeatability in two optical coherence tomography (OCT) systems: the Stratus OCT, a time domain system, and the Cirrus HD-OCT, a spectral domain system (both by Carl Zeiss Meditec, Inc., Dublin, CA), in the context of diabetic macular edema (DME). Thirty-three eyes of 33 diabetic patients with clinically significant macular edema (CSME) were scanned in a single session by a single operator on both OCT systems. Macular thickness measurements of nine standard macular subfields and total macular volume were obtained and analyzed. Bland-Altman plots were constructed to assess agreement in macular measurements. Intraclass correlation coefficients (ICCs), coefficients of repeatability (CR(W)), and coefficients of variation (CV(W)) were used to assess intrasession repeatability. Macular thickness in nine retinal subfields and macular volume were significantly higher in the Cirrus HD-OCT system compared with the Stratus OCT system. Subfield thickness and total volume measurements, respectively, were 30 to 55 microm and 3.2 mm(3) greater for the Cirrus HD-OCT system compared with the Stratus OCT system. Both Stratus OCT and Cirrus HD-OCT systems demonstrated high intrasession repeatability, with overlapping ranges for CR(W), CV(W), and ICC. Repeatability measures (CR(W) and CV(W)) differed significantly between systems in only one of nine subfields (outer temporal subfield). Absolute measures of macular thickness and volume in patients with DME differed significantly in magnitude between the Stratus OCT and Cirrus HD-OCT systems. However, both OCT systems demonstrated high intrasessional repeatability. Although the two systems may not be used interchangeably, they appear equally reliable in generating macular measurements for clinical practice and research.
ICPP tank farm closure study. Volume 2: Engineering design files
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-02-01
Volume 2 contains the following topical sections: Tank farm heel flushing/pH adjustment; Grouting experiments for immobilization of tank farm heel; Savannah River high level waste tank 20 closure; Tank farm closure information; Clean closure of tank farm; Remediation issues; Remote demolition techniques; Decision concerning EIS for debris treatment facility; CERCLA/RCRA issues; Area of contamination determination; Containment building of debris treatment facility; Double containment issues; Characterization costs; Packaging and disposal options for the waste resulting from the total removal of the tank farm; Take-off calculations for the total removal of soils and structures at the tank farm; Vessel off-gas systems; Jet-groutedmore » polymer and subsurface walls; Exposure calculations for total removal of tank farm; Recommended instrumentation during retrieval operations; High level waste tank concrete encasement evaluation; Recommended heavy equipment and sizing equipment for total removal activities; Tank buoyancy constraints; Grout and concrete formulas for tank heel solidification; Tank heel pH requirements; Tank cooling water; Evaluation of conservatism of vehicle loading on vaults; Typical vault dimensions and approximately tank and vault void volumes; Radiological concerns for temporary vessel off-gas system; Flushing calculations for tank heels; Grout lift depth analysis; Decontamination solution for waste transfer piping; Grout lift determination for filling tank and vault voids; sprung structure vendor data; Grout flow properties through a 2--4 inch pipe; Tank farm load limitations; NRC low level waste grout; Project data sheet calculations; Dose rates for tank farm closure tasks; Exposure and shielding calculations for grout lines; TFF radionuclide release rates; Documentation of the clean closure of a system with listed waste discharge; and Documentation of the ORNL method of radionuclide concentrations in tanks.« less
NASA Technical Reports Server (NTRS)
Feigenbaum, H.; Kaufman, A.; Wang, C. L.; Werth, J.; Whelan, J. A.
1983-01-01
Operating experience with a 5kW methanol-air integrated system is described. On-going test results for a 24-cell, two-sq ft (4kW) stack are reported. The main activity for this stack is currently the evaluation of developmental non-metalic cooling plates. Single-cell test results are presented for a promising developmental cathode catalyst.
EVALUATION OF THE EFFECT OF SCR ON MERCURY SPECIATION AND EMISSIONS
The paper presents the results of an investigation on the impact that selective catalytic reduction (SCR) has on both the total emissions and the speciation of mercury (Hg). SCR systems can be used as multipollutant technologies if they enhance Hg conversion/capture. Previous pil...
40 CFR Appendix E to Subpart E of... - Innovative and Alternative Technology Guidelines
Code of Federal Regulations, 2012 CFR
2012-07-01
... Technology Guidelines 1. Purpose. These guidelines provide the criteria for identifying and evaluating... industrial and other nonpotable purposes, horticulture and revegetation of disturbed land. Total containment... alternative technology systems for the purpose of this section. b. For sludges, these include land application...
40 CFR Appendix E to Subpart E of... - Innovative and Alternative Technology Guidelines
Code of Federal Regulations, 2014 CFR
2014-07-01
... Technology Guidelines 1. Purpose. These guidelines provide the criteria for identifying and evaluating... industrial and other nonpotable purposes, horticulture and revegetation of disturbed land. Total containment... alternative technology systems for the purpose of this section. b. For sludges, these include land application...
40 CFR Appendix E to Subpart E of... - Innovative and Alternative Technology Guidelines
Code of Federal Regulations, 2013 CFR
2013-07-01
... Technology Guidelines 1. Purpose. These guidelines provide the criteria for identifying and evaluating... industrial and other nonpotable purposes, horticulture and revegetation of disturbed land. Total containment... alternative technology systems for the purpose of this section. b. For sludges, these include land application...
40 CFR Appendix E to Subpart E of... - Innovative and Alternative Technology Guidelines
Code of Federal Regulations, 2011 CFR
2011-07-01
... Technology Guidelines 1. Purpose. These guidelines provide the criteria for identifying and evaluating... industrial and other nonpotable purposes, horticulture and revegetation of disturbed land. Total containment... alternative technology systems for the purpose of this section. b. For sludges, these include land application...
NASA Astrophysics Data System (ADS)
Chaianong, A.; Bangviwat, A.; Menke, C.
2017-07-01
Driven by decreasing PV and energy storage prices, increasing electricity costs and policy supports from Thai government (self-consumption era), rooftop PV and energy storage systems are going to be deployed in the country rapidly that may disrupt existing business models structure of Thai distribution utilities due to revenue erosion and lost earnings opportunities. The retail rates that directly affect ratepayers (non-solar customers) are expected to increase. This paper focuses on a framework for evaluating impacts of PV with and without energy storage systems on Thai distribution utilities and ratepayers by using cost-benefit analysis (CBA). Prior to calculation of cost/benefit components, changes in energy sales need to be addressed. Government policies for the support of PV generation will also help in accelerating the rooftop PV installation. Benefit components include avoided costs due to transmission losses and deferring distribution capacity with appropriate PV penetration level, while cost components consist of losses in revenue, program costs, integration costs and unrecovered fixed costs. It is necessary for Thailand to compare total costs and total benefits of rooftop PV and energy storage systems in order to adopt policy supports and mitigation approaches, such as business model innovation and regulatory reform, effectively.
Cost-Effective Mobile-Based Healthcare System for Managing Total Joint Arthroplasty Follow-Up.
Bitsaki, Marina; Koutras, George; Heep, Hansjoerg; Koutras, Christos
2017-01-01
Long-term follow-up care after total joint arthroplasty is essential to evaluate hip and knee arthroplasty outcomes, to provide information to physicians and improve arthroplasty performance, and to improve patients' health condition. In this paper, we aim to improve the communication between arthroplasty patients and physicians and to reduce the cost of follow-up controls based on mobile application technologies and cloud computing. We propose a mobile-based healthcare system that provides cost-effective follow-up controls for primary arthroplasty patients through questions about symptoms in the replaced joint, questionnaires (WOMAC and SF-36v2) and the radiological examination of knee or hip joint. We also perform a cost analysis for a set of 423 patients that were treated in the University Clinic for Orthopedics in Essen-Werden. The estimation of healthcare costs shows significant cost savings (a reduction of 63.67% for readmission rate 5%) in both the University Clinic for Orthopedics in Essen-Werden and the state of North Rhine-Westphalia when the mobile-based healthcare system is applied. We propose a mHealth system to reduce the cost of follow-up assessments of arthroplasty patients through evaluation of diagnosis, self-monitoring, and regular review of their health status.
Ungprasert, Patompong; Wilton, Katelynn M; Ernste, Floranne C; Kalra, Sanjay; Crowson, Cynthia S; Rajagopalan, Srinivasan; Bartholmai, Brian J
2017-10-01
To evaluate the correlation between measurements from quantitative thoracic high-resolution CT (HRCT) analysis with "Computer-Aided Lung Informatics for Pathology Evaluation and Rating" (CALIPER) software and measurements from pulmonary function tests (PFTs) in patients with idiopathic inflammatory myopathies (IIM)-associated interstitial lung disease (ILD). A cohort of patients with IIM-associated ILD seen at Mayo Clinic was identified from medical record review. Retrospective analysis of HRCT data and PFTs at baseline and 1 year was performed. The abnormalities in HRCT were quantified using CALIPER software. A total of 110 patients were identified. At baseline, total interstitial abnormalities as measured by CALIPER, both by absolute volume and by percentage of total lung volume, had a significant negative correlation with diffusing capacity for carbon monoxide (DLCO), total lung capacity (TLC), and oxygen saturation. Analysis by subtype of interstitial abnormality revealed significant negative correlations between ground glass opacities (GGO) and reticular density (RD) with DLCO and TLC. At one year, changes of total interstitial abnormalities compared with baseline had a significant negative correlation with changes of TLC and oxygen saturation. A negative correlation between changes of total interstitial abnormalities and DLCO was also observed, but it was not statistically significant. Analysis by subtype of interstitial abnormality revealed negative correlations between changes of GGO and RD and changes of DLCO, TLC, and oxygen saturation, but most of the correlations did not achieve statistical significance. CALIPER measurements correlate well with functional measurements in patients with IIM-associated ILD.
Development and calibration of an accurate 6-degree-of-freedom measurement system with total station
NASA Astrophysics Data System (ADS)
Gao, Yang; Lin, Jiarui; Yang, Linghui; Zhu, Jigui
2016-12-01
To meet the demand of high-accuracy, long-range and portable use in large-scale metrology for pose measurement, this paper develops a 6-degree-of-freedom (6-DOF) measurement system based on total station by utilizing its advantages of long range and relative high accuracy. The cooperative target sensor, which is mainly composed of a pinhole prism, an industrial lens, a camera and a biaxial inclinometer, is designed to be portable in use. Subsequently, a precise mathematical model is proposed from the input variables observed by total station, imaging system and inclinometer to the output six pose variables. The model must be calibrated in two levels: the intrinsic parameters of imaging system, and the rotation matrix between coordinate systems of the camera and the inclinometer. Then corresponding approaches are presented. For the first level, we introduce a precise two-axis rotary table as a calibration reference. And for the second level, we propose a calibration method by varying the pose of a rigid body with the target sensor and a reference prism on it. Finally, through simulations and various experiments, the feasibilities of the measurement model and calibration methods are validated, and the measurement accuracy of the system is evaluated.
Financial performance of the teaching pharmacies in Isfahan: an economic evaluation
Sabzghabaee, A.M.; Etebari, M.; Sajjadi, H.; Badri, Sh.; Hosseini-Biuki, S.M.; Sheikhaboumasoudi, R.
2009-01-01
Teaching pharmacies are amongst the important cornerstones of a healthcare system for drug supplying, pharmacy education and pharmacy practice research. Assessment of the Iranian healthcare system costs shows that after personnel charges, drug outlay is the second expensive factor. This great financial mass requires integral audit and management in order to provide costumers satisfaction in addition to financial viability. Teaching pharmacies are required to realize financial viability as well as providing several educational and drug servicing goals, which makes microeconomic analysis important. The aim of this study was to evaluate the financial performance of the teaching pharmacies affiliated with the Isfahan University of Medical Sciences (with the abrreviated names as: SHM, ISJ, AZH for the confidentialiy of the financial data). This is a descriptive and cross-sectional study done in 2008. The target pharmacies of this study were all the 3 teaching pharmacies affiliated with the Isfahan University of Medical Sciences. The data collecting template was prepared using the standard scientific methods according to the goals of this research The goals also nominated necessary items needed in economic profit evaluation. The data collection template was completed by reference to the teaching pharmacies financial documents and reports, used as a base for calculating the total income and the total costs in 2007-2008 financial year. The difference between these two balances showed the value of profits or loss. The profit/cost ratio was also calculated, using the proportion of the total income to the total costs. The collected data was statistically analyzed using the Excel software (Microsoft 2007). For the financial year 2007-2008, the difference between the total income and the total costs was -831.6 million Rials (excess costs to income) for the SHM pharmacy, + 25.4 billion Rials for the ISJ pharmacy and -429.5 million Rials for the AZH pharmacy. According to our findings there is a strong requirement to improve the financial performance of all the three teaching pharmacies while maintaining a high standardard of teaching and educational affairs. PMID:21589804
NASA Astrophysics Data System (ADS)
Wright-Walker, Cassandra Jane
Each year in the United States there is an increasing trend of patients receiving total joint replacement (TJR) procedures. Approximately a half million total knee replacements (TKRs) are performed annually in the United States with increasing prevalence attributed to baby-boomers, obesity, older, and younger patients. This trend is also seen for total hip replacements (THRs) as well. The use of ultra high molecular weight polyethylene (UHMWPE) inserts in TJRs results in wear particle-induced osteolysis, which is the predominant cause for prosthesis failure and revision surgery. Sub-micron size particle generation is inevitable despite the numerous efforts in improving this bearing material. Work by others has shown that the use of oral and intravenous systemic bisphosphonates (BP) can significantly minimize periprosthetic osteolysis. However, the systemic delivery and the high solubility of BPs results in a predominant portion of the drug being excreted via the kidney without reaching its target, bone. This doctoral research project is focused on the development and evaluation of a novel method to administer BPs locally using the inherent wear of UHMWPE for possible use as an anti-osteolysis treatment. For new materials to be considered, they must be mechanically and tribologically comparable to the current gold standard, UHMWPE. In order to evaluate this material, mechanical, drug elution and tribological experiments were performed to allow assessment of material properties. Tensile tests showed comparable yield stress and pin-on-disk testing showed comparable wear to standard virgin UHMWPE. Further, drug elution tests have shown that BP was released from the enriched material both in static and dynamic conditions. Additionally, an aggressive 2 million cycle total knee simulator experiment has shown statistically similar wear results for the two materials. Overall, this research has provided the groundwork for further characterization and development of a new potential material for total joint replacements as an enhancement to standard UHMWPE. This material shows significant potential as an alternative bearing material to indirectly increase TJR longevity by addressing osteolysis related issues.
Financial performance of the teaching pharmacies in Isfahan: an economic evaluation.
Sabzghabaee, A M; Etebari, M; Sajjadi, H; Badri, Sh; Hosseini-Biuki, S M; Sheikhaboumasoudi, R
2009-07-01
Teaching pharmacies are amongst the important cornerstones of a healthcare system for drug supplying, pharmacy education and pharmacy practice research. Assessment of the Iranian healthcare system costs shows that after personnel charges, drug outlay is the second expensive factor. This great financial mass requires integral audit and management in order to provide costumers satisfaction in addition to financial viability. Teaching pharmacies are required to realize financial viability as well as providing several educational and drug servicing goals, which makes microeconomic analysis important. The aim of this study was to evaluate the financial performance of the teaching pharmacies affiliated with the Isfahan University of Medical Sciences (with the abrreviated names as: SHM, ISJ, AZH for the confidentialiy of the financial data). This is a descriptive and cross-sectional study done in 2008. The target pharmacies of this study were all the 3 teaching pharmacies affiliated with the Isfahan University of Medical Sciences. The data collecting template was prepared using the standard scientific methods according to the goals of this research The goals also nominated necessary items needed in economic profit evaluation. The data collection template was completed by reference to the teaching pharmacies financial documents and reports, used as a base for calculating the total income and the total costs in 2007-2008 financial year. The difference between these two balances showed the value of profits or loss. The profit/cost ratio was also calculated, using the proportion of the total income to the total costs. The collected data was statistically analyzed using the Excel software (Microsoft 2007). For the financial year 2007-2008, the difference between the total income and the total costs was -831.6 million Rials (excess costs to income) for the SHM pharmacy, + 25.4 billion Rials for the ISJ pharmacy and -429.5 million Rials for the AZH pharmacy. According to our findings there is a strong requirement to improve the financial performance of all the three teaching pharmacies while maintaining a high standardard of teaching and educational affairs.
Jain, Shruti; Guleria, Kiran; Suneja, Amita; Vaid, Neelam B; Ahuja, Sharmila
2016-03-01
To evaluate the prognostic value of the Sequential Organ Failure Assessment (SOFA) score among obstetric patients admitted to the intensive care unit (ICU). A prospective study was conducted among 90 consecutive obstetric patients who were admitted to the ICU of Guru Teg Bahadur Hospital, Delhi, India, between October 6, 2010, and December 25, 2011. Maximum SOFA score was calculated for each of the six organ systems. Receiver operating characteristic curves were used to determine critical cutoff values for total, maximum total, and mean total SOFA scores at various time points. Total SOFA score at admission displayed an area under the curve (AUC) of 0.949, a cutoff value of at least 8.5, sensitivity of 86.7%, and specificity of 90.0%. Maximum total SOFA score had an AUC of 0.980, a cutoff value of at least 10.0, sensitivity of 96.7%, and specificity of 90.0%. Mean total SOFA score had an AUC of 0.997, a cutoff value of at least 9.0, sensitivity of 96.7%, and specificity of 96.7%. In terms of discriminatory power for predicting mortality among obstetric patients admitted to the ICU, total SOFA score at admission was the most relevant, simple, and accurate measure. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Satellite Power Systems (SPS) concept definition study (exhibit C)
NASA Technical Reports Server (NTRS)
Hanley, G. M.
1978-01-01
A coplanar satellite conceptual approach was defined. This effort included several trade studies related to satellite design and also construction approaches for this satellite. A transportation system, consistent with this concept, was also studied, including an electric orbit transfer vehicle and a parallel-burn heavy lift launch vehicle. Work on a solid state microwave concept continued and several alternative approaches were evaluated. Computer determination of an optimized transistor and circuit design was also continued. Experiment/verification planning resulted in the development of a total solar array and microwave technology development plan, as well as definition of near-term research to evaluate key technology issues.
Electric Propulsion Options for 10 kW Class Earth-Space Missions
NASA Technical Reports Server (NTRS)
Patterson, M. J.; Curran, Francis M.
1989-01-01
Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment were evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA 2 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10 (exp 7) to 2.1x10 (exp 7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA 2 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10 (exp 6) to 3.6x10 (exp 6) N-s, and approximately 662 to 1072 m/s, respectively.
Sorenson, Jason R.; Granato, Gregory E.; Smith, Kirk P.
2018-01-10
Flow-proportional composite water samples were collected in water years 2013 and 2014 by the U.S. Geological Survey, in cooperation with the Massachusetts Department of Environmental Protection, from the Blackstone River at Millville, Massachusetts (U.S. Geological Survey station 01111230), about 0.5 mile from the border with Rhode Island. Samples were collected in order to better understand the dynamics of selected nutrient and metal constituents, assist with planning, guide activities to meet water-quality goals, and provide real-time water-quality information to the public. An automated system collected the samples at 14-day intervals to determine total and dissolved nitrogen and phosphorus concentrations, to provide accurate monthly nutrient concentration data, and to calculate monthly load estimates. Concentrations of dissolved trace metals and total aluminum were determined from 4-day composite water samples that were collected twice monthly by the automated system. Results from 4-day composites provide stakeholders with information to evaluate trace metals on the basis of chronic 4-day exposure criteria for aquatic life, and the potential to use the biotic ligand model to evaluate copper concentrations. Nutrient, trace metal, suspended sediment, dissolved organic carbon, and chlorophyll a concentrations were determined from discrete samples collected at the Millville station and from across the stream transect at the upstream railroad bridge, and these concentrations served as a means to evaluate the representativeness of the Millville point location.Analytical results from samples collected with the automated flow-proportional sampling system provided the means to calculate monthly and annual loading data. Total nitrogen and total phosphorus loads in water year (WY) 2013 were about 447,000 and 36,000 kilograms (kg), respectively. In WY 2014, annual loads of total nitrogen and total phosphorus were about 342,000 and 21,000 kg, respectively. Total nitrogen and total phosphorus loads from WYs 2013 and 2014 were about 56 and 65 percent lower than those reported for WYs 2008 and 2009. The higher loads in 2008 and 2009 may be explained by the higher than average flows in WY 2009 and by facility upgrades made by wastewater treatment facilities in the basin.Median loads were determined from composite samples collected with the automated system between October 2012 and October 2014. Median dissolved cadmium and chromium 4-day loads were 0.55 and 0.84 kg, respectively. Dissolved copper and total lead median 4-day loads were 8.02 and 1.42 kg, respectively. The dissolved nickel median 4-day load was 5.45 kg, and the dissolved zinc median 4-day load was 36 kg. Median total aluminum 4-day loads were about 197 kg.Spearman’s rank correlation analyses were used with discrete sample concentrations and continuous records of temperature, specific conductance, turbidity, and chlorophyll a to identify correlations between variables that could be used to develop regression equations for estimating real-time concentrations of constituents. Correlation coefficients were generated for flow, precipitation, antecedent precipitation, physical parameters, and chemical constituents. A 95-percent confidence limit for each value of Spearman’s rho was calculated, and multiple linear regression analysis using ordinary least squares regression techniques was used to develop regression equations for concentrations of total phosphorus, total nitrogen, suspended sediment concentration, total copper, and total aluminum. Although the correlations are based on the limited amount of data collected as part of this study, the potential to monitor water-quality changes in real time may be of value to resource managers and decision makers.
Aramaki, T; Sugimoto, R; Hanaki, K; Matsuo, T
2001-01-01
The appropriate type of reclaimed wastewater reuse system in each area of Tokyo was evaluated from the aspect of economic efficiency, using a GIS-based water balances model. The following four reclaimed wastewater reuse systems and conventional waterworks and sewerage system were evaluated; "Rain water storage and use system", "Onsite wastewater treatment and reuse system", "Sewage treatment and reuse at an intermediate point on the sewer pipe" and "Treated water supply system in sewage treatment plant". In the case that we install them to office and residential buildings, the supplied volume by reclaimed wastewater reuse systems is 693 thousands m3/d, this corresponds to 15% of total water demand in the area. Furthermore, the effects of the following scenarios brought about by technological innovation in water treatment were investigated; the case that flush water in toilet and wastewater from kitchen are also available as source in a "onsite wastewater treatment and reuse system" and the case that reclaimed water is used for laundering in residential buildings. When reclaimed water is used for laundering in residential buildings, the supplied volume by these systems increases to 814 thousand m3/d in the case that these systems are installed to office and residential buildings.
NASA Astrophysics Data System (ADS)
Dalipi, Rogerta; Marguí, Eva; Borgese, Laura; Bilo, Fabjola; Depero, Laura E.
2016-06-01
Recent technological improvements have led to a widespread adoption of benchtop total reflection X-ray fluorescence systems (TXRF) for analysis of liquid samples. However, benchtop TXRF systems usually present limited sensitivity compared with high-scale instrumentation which can restrict its application in some fields. The aim of the present work was to evaluate and compare the analytical capabilities of two TXRF systems, equipped with low power Mo and W target X-ray tubes, for multielemental analysis of wine samples. Using the Mo-TXRF system, the detection limits for most elements were one order of magnitude lower than those attained using the W-TXRF system. For the detection of high Z elements like Cd and Ag, however, W-TXRF remains a very good option due to the possibility of K-Lines detection. Accuracy and precision of the obtained results have been evaluated analyzing spiked real wine samples and comparing the TXRF results with those obtained by inductively coupled plasma emission spectroscopy (ICP-OES). In general, good agreement was obtained between ICP-OES and TXRF results for the analysis of both red and white wine samples except for light elements (i.e., K) which TXRF concentrations were underestimated. However, a further achievement of analytical quality of TXRF results can be achieved if wine analysis is performed after dilution of the sample with de-ionized water.
Grubbs, J.W.
1995-01-01
Temporal and spatial distributions of ground-water inflow to, and leakage from Lake Five-O, a softwater, seepage lake in northwestern Florida, were evaluated using hydrologic data and simulation models of the shallow ground-water system adjacent to the lake. The simulation models indicate that ground-water inflow to the lake and leakage from the lake to the ground-water system are the dominant components in the total inflow (precipitation plus ground-water inflow) and total outflow (evaporation plus leakage) budgets of Lake Five-O. Simlulated ground-water inflow and leakage were approximately 4 and 5 times larger than precipitation inputs and evaporative losses, respectively, during calendar years 1989-90. Exchanges of water between Lake Five-O and the ground-water system were consistently larger than atmospheric-lake exchanges. A consistent pattern of shallow ground-water inflow and deep leakage was also evident throughout the study period. The mean time of travel from ground-water that discharges at Lake Five-O (time from recharge at the water table to discharge at the lake) was estimated to be within a range of 3 to 6 years. Flow-path evaluations indicated that the intermediate confining unit probably has a negligible influence on the geochemistry of ground-water inflow to Lake Five-O. The hydrologic budgets and flow-path evaluations provide critical information for developing geochemical budgets for Lake Five-O and for improving the understanding of the relative importance of various processes that regulate the acid-neutralizing capacity of softwater seepage lakes in Florida.
Choi, Il; Lee, Hyunjoo; Shin, Joungdu; Kim, Hyunook
2012-01-01
Sewer odors have been a concern to citizens of the Metropolitan Seoul region, which has installed combined sewer systems (CSSs) in 86% of its area. Although a variety of odorants are released from sewers, volatile sulfur compounds (VSCs) have been recognized as major ones. A number of technologies have been proposed to monitor or control odors from sewers. One of the most popular strategies adopted for the control of sewage odor is by applying a commercial odor-reducing agent into the sewer. In this study, the effectiveness of five different commercial odor-reducing agents (i.e., an odor masking agent, an alkaline solution, two microbial agents, and a chemical oxidant) was evaluated by continuously monitoring VSCs released from the sewer with an on-line total reduced sulfur (TRS) analyzer before and after each agent was sprayed into CSSs at five different locations of the city. In short, when the effectiveness of odor treatment was tested in the sewer system using five commercial odor reducing treatments, only the chemical oxidant was good enough to reduce the odor in terms of TRS levels measured before and after the application (p < 0.01). PMID:23223148
Local electric dipole moments for periodic systems via density functional theory embedding.
Luber, Sandra
2014-12-21
We describe a novel approach for the calculation of local electric dipole moments for periodic systems. Since the position operator is ill-defined in periodic systems, maximally localized Wannier functions based on the Berry-phase approach are usually employed for the evaluation of local contributions to the total electric dipole moment of the system. We propose an alternative approach: within a subsystem-density functional theory based embedding scheme, subset electric dipole moments are derived without any additional localization procedure, both for hybrid and non-hybrid exchange-correlation functionals. This opens the way to a computationally efficient evaluation of local electric dipole moments in (molecular) periodic systems as well as their rigorous splitting into atomic electric dipole moments. As examples, Infrared spectra of liquid ethylene carbonate and dimethyl carbonate are presented, which are commonly employed as solvents in Lithium ion batteries.
NRCMS capitation reform and effect evaluation in Pudong New Area of Shanghai.
Jing, Limei; Bai, Jie; Sun, Xiaoming; Zakus, David; Lou, Jiquan; Li, Ming; Zhang, Qunfang; Zhuang, Yuehong
2016-07-01
The Rural Cooperative Medical Scheme (RCMS) had played an important role in guaranteeing the acquisition of basic medical healthcare of China's rural populations, being an innovative model of the medical insurance system for so many years here in China. Following the boom and bust of RCMS, the central government rebuilt the New Rural Cooperative Medical Scheme (NRCMS) in 2003 across the whole country. Shanghai, one of the developed cities in China, has developed its RCMS and NRCMS as an advanced and exemplary representative of Chinese rural health insurance. But in the past 10 years, its NRCMS has encountered such challenges as a spiral of medical expenditures and a decrease of insurance participants. Previous investigations showed that the capitation and general practitioner (GP) system had great effect on medical cost containment. Thus, the capitation reform combined with GP system reform of NRCMS, based on a system design, was implemented in Pudong New Area of Shanghai as of 1 August 2012. The aim of the current investigation was to present how the reform was designed and implemented, evaluating its effect by analyzing the data acquired from 12 months before and after the reform. This was an empirical study; we made a conceptual design of the reform to be implemented in Pudong New Area. Most data were derived from the institution-based surveys and supplemented by a questionnaire survey, qualitative interviews and policy document analysis. We found that most respondents held an optimistic attitude towards the reform. We employed a structure-process-outcome evaluation index system to evaluate the effect of the reform, finding that the growth rate of the insured population's total medical costs and NRCMS funds slowed down significantly after the reform; that the total medical expenditure of the insured rural population decreased by 3.60%; and that the total expenditure of NRCMS decreased by 3.99%. The capitation was found to help the medical staff build active cost control consciousness. Approximately 2.3% of the outpatients flowed to the primary hospitals from the secondary hospitals; and farmers' annual medical burden was relieved to a certain degree. Meanwhile, it did not affect farmers' utilization and benefits of healthcare. However, further reform still faces new challenges: The capitation reform should be well combined with the primary healthcare system to realize the "dual gatekeeper" of GPs; a variety of payment methods should be mixed on the basis of capitation to avoid possible mistakes by one single approach; and the supervision of medical institutions should be strengthened. A long-term follow-up study need to be carried out to evaluate the effects of the capitation reform so as to improve the design of the program. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Xian, Qiming; Hu, Lixia; Chen, Hancheng; Chang, Zhizhou; Zou, Huixian
2010-12-01
The potential of three varieties of Italian ryegrass (Lolium multiflorum Lam.), Dryan, Tachimasari and Waseyutaka, to improve the water quality of swine wastewater was evaluated using a constructed macrophyte floating bed system. With respect to reductions in levels of nutrients, chemical oxygen demand (COD), and sulfonamide antimicrobials (SAs, including sulfadiazine, sulfamethazine, and sulfamethoxazole), Dryan performed better than Tachimasari and Waseyutaka. For Dryan, total N was reduced by 84.0%, total P by 90.4%, COD by 83.4% and sulfonamide antimicrobials by 91.8-99.5%. Similar results were observed for Tachimasari and Waseyutaka. The results indicated that the treatment of swine wastewater using the constructed macrophyte floating bed system was effective in the removal of nutrients and veterinary antibiotics. Copyright © 2010 Elsevier Ltd. All rights reserved.
Min, Yul Ha; Park, Hyeoun-Ae; Lee, Joo Yun; Jo, Soo Jung; Jeon, Eunjoo; Byeon, Namsoo; Choi, Seung Yong; Chung, Eunja
2014-01-01
The aim of this study is to develop and evaluate a natural language generation system to populate nursing narratives using detailed clinical models. Semantic, contextual, and syntactical knowledges were extracted. A natural language generation system linking these knowledges was developed. The quality of generated nursing narratives was evaluated by the three nurse experts using a five-point rating scale. With 82 detailed clinical models, in total 66,888 nursing narratives in four different types of statement were generated. The mean scores for overall quality was 4.66, for content 4.60, for grammaticality 4.40, for writing style 4.13, and for correctness 4.60. The system developed in this study generated nursing narratives with different levels of granularity. The generated nursing narratives can improve semantic interoperability of nursing data documented in nursing records.
Computational Design of a Krueger Flap Targeting Conventional Slat Aerodynamics
NASA Technical Reports Server (NTRS)
Akaydin, H. Dogus; Housman, Jeffrey A.; Kiris, Cetin C.; Bahr, Christopher J.; Hutcheson, Florence V.
2016-01-01
In this study, we demonstrate the design of a Krueger flap as a substitute for a conventional slat in a high-lift system. This notional design, with the objective of matching equivalent-mission performance on aircraft approach, was required for a comparative aeroacoustic study with computational and experimental components. We generated a family of high-lift systems with Krueger flaps based on a set of design parameters. Then, we evaluated the high-lift systems using steady 2D RANS simulations to find a good match for the conventional slat, based on total lift coefficients in free-air. Finally, we evaluated the mean aerodynamics of the high-lift systems with Krueger flap and conventional slat as they were installed in an open-jet wind tunnel flow. The surface pressures predicted with the simulations agreed well with experimental results.
NASA Technical Reports Server (NTRS)
Garland, J. L.; Cook, K. L.; Johnson, M.; Sumner, R.; Fields, N.; Sager, J. C. (Principal Investigator)
1997-01-01
A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 1/2-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estunate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.
NASA Astrophysics Data System (ADS)
Garland, J. L.; Cook, K. L.; Johnson, M.; Sumner, R.; Fields, N.
1997-01-01
A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 1/2-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estimate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.
NASA Astrophysics Data System (ADS)
1997-01-01
A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard
A computerized system to evaluate volumetric infusion pumps.
Kobayashi, S; Ogata, T
1992-01-01
A computerized system was developed to examine the performance characteristics of infusion pumps. This system collects solution delivered by an infusion pump through an intravenous needle into a collection vessel. Using an inductor-type weight sensor and a semiconductor type of strain-gauge pressure sensor, the weight of the collection vessel and the pressure at the needle were monitored over a specific period (the sampling time), and changes in pressure, flow rate, and volume of fluid were calculated. This system was applied to five volumetric infusion pumps with different pumping mechanisms. Test conditions involved two different solutions, two sizes of needle gauge, and seven flow rates, for a total of 28 measurements per pump. Results showed considerable variation in the infusion pumps' performances based on differences in these indices. Use of an inductance weight sensor as a means to evaluate gravimetric performance appears to be an improvement over conventional methods, which use analytical balances for data generation. The results indicate that this system will be useful in evaluating the performances of commercially available infusion pumps as well as those in development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nyflot, MJ; Kusano, AS; Zeng, J
Purpose: Interest in incident learning systems (ILS) for improving safety and quality in radiation oncology is growing, as evidenced by the upcoming release of the national ILS. However, an institution implementing such a system would benefit from quantitative metrics to evaluate performance and impact. We developed metrics to measure volume of reporting, severity of reported incidents, and changes in staff attitudes over time from implementation of our institutional ILS. Methods: We analyzed 2023 incidents from our departmental ILS from 2/2012–2/2014. Incidents were prospectively assigned a near-miss severity index (NMSI) at multidisciplinary review to evaluate the potential for error ranging frommore » 0 to 4 (no harm to critical). Total incidents reported, unique users reporting, and average NMSI were evaluated over time. Additionally, departmental safety attitudes were assessed through a 26 point survey adapted from the AHRQ Hospital Survey on Patient Safety Culture before, 12 months, and 24 months after implementation of the incident learning system. Results: Participation in the ILS increased as demonstrated by total reports (approximately 2.12 additional reports/month) and unique users reporting (0.51 additional users reporting/month). Also, the average NMSI of reports trended lower over time, significantly decreasing after 12 months of reporting (p<0.001) but with no significant change at months 18 or 24. In survey data significant improvements were noted in many dimensions, including perceived barriers to reporting incidents such as concern of embarrassment (37% to 18%; p=0.02) as well as knowledge of what incidents to report, how to report them, and confidence that these reports were used to improve safety processes. Conclusion: Over a two-year period, our departmental ILS was used more frequently, incidents became less severe, and staff confidence in the system improved. The metrics used here may be useful for other institutions seeking to create or evaluate their own incident learning systems.« less
Calba, Clémentine; Goutard, Flavie Luce; Vanholme, Luc; Antoine-Moussiaux, Nicolas; Hendrikx, Pascal; Saegerman, Claude
2016-01-01
Context and Objective Bovine tuberculosis (bTB) surveillance in Belgium is essential to maintain the officially free status and to preserve animal and public health. An evaluation of the system is thus needed to ascertain the surveillance provides a precise description of the current situation in the country. The evaluation should assess stakeholders’ perceptions and expectations about the system due to the fact that the acceptability has an influence on the levels of sensitivity and timeliness of the surveillance system. The objective of the study was to assess the acceptability of the bTB surveillance in Belgium, using participatory tools and the OASIS flash tool (‘analysis tool for surveillance systems’). Methods For the participatory process, focus group discussions and individual interviews were implemented with representatives involved with the system, both from cattle and wildlife part of the surveillance. Three main tools were used: (i) relational diagrams associated with smileys, (ii) flow diagrams associated with proportional piling, and (iii) impact diagrams associated with proportional piling. A total of six criteria were assessed, among which five were scored on a scale from -1 to +1. For the OASIS flash tool, one full day meeting with representatives from stakeholders involved with the surveillance was organised. A total of 19 criteria linked to acceptability were scored on a scale from 0 to 3. Results and Conclusion Both methods highlighted a medium acceptability of the bTB surveillance. The main elements having a negative influence were the consequences of official notification of a bTB suspect case in a farm, the low remuneration paid to private veterinarians for execution of intradermal tuberculin tests and the practical difficulties about the containment of the animals. Based on the two evaluation processes, relevant recommendations to improve the surveillance were made. Based on the comparison between the two evaluation processes, the added value of the participatory approach was highlighted. PMID:27462705
Biomedical question answering using semantic relations.
Hristovski, Dimitar; Dinevski, Dejan; Kastrin, Andrej; Rindflesch, Thomas C
2015-01-16
The proliferation of the scientific literature in the field of biomedicine makes it difficult to keep abreast of current knowledge, even for domain experts. While general Web search engines and specialized information retrieval (IR) systems have made important strides in recent decades, the problem of accurate knowledge extraction from the biomedical literature is far from solved. Classical IR systems usually return a list of documents that have to be read by the user to extract relevant information. This tedious and time-consuming work can be lessened with automatic Question Answering (QA) systems, which aim to provide users with direct and precise answers to their questions. In this work we propose a novel methodology for QA based on semantic relations extracted from the biomedical literature. We extracted semantic relations with the SemRep natural language processing system from 122,421,765 sentences, which came from 21,014,382 MEDLINE citations (i.e., the complete MEDLINE distribution up to the end of 2012). A total of 58,879,300 semantic relation instances were extracted and organized in a relational database. The QA process is implemented as a search in this database, which is accessed through a Web-based application, called SemBT (available at http://sembt.mf.uni-lj.si ). We conducted an extensive evaluation of the proposed methodology in order to estimate the accuracy of extracting a particular semantic relation from a particular sentence. Evaluation was performed by 80 domain experts. In total 7,510 semantic relation instances belonging to 2,675 distinct relations were evaluated 12,083 times. The instances were evaluated as correct 8,228 times (68%). In this work we propose an innovative methodology for biomedical QA. The system is implemented as a Web-based application that is able to provide precise answers to a wide range of questions. A typical question is answered within a few seconds. The tool has some extensions that make it especially useful for interpretation of DNA microarray results.
ERIC Educational Resources Information Center
Schanie, Charles F.; Kemper, James E.
2008-01-01
Most "performance evaluation" or "performance development" programs in higher education today are little more than metrically-weak, bureaucratic programs aimed simply at establishing a legally-grounded employee record and a rough basis for merit increases. This article outlines the rationale and procedural framework for a talent development and…
USDA-ARS?s Scientific Manuscript database
To meet Chesapeake Bay Total Maximum Daily Load requirements for agricultural pollution, conservation districts and farmers are tasked with implementing best management practices (BMPs) that reduce farm losses of nutrients and sediment. The importance of the agricultural industry to the regional eco...
Total Energy Concepts as Applied to Universities.
ERIC Educational Resources Information Center
Gudgeon, R.L.
A comprehensive discussion of single fuel source generation of power and heating requirements is presented. Definition and explanation of system concepts includes--(1) heat pumps, (2) steam turbines, (3) gas turbines, and (4) gas and diesel engines. Concept cost evaluation factors described are--(1) load pattern, (2) campus configuration, (3) fuel…
Setting Priorities for NIOSH Research
ERIC Educational Resources Information Center
Gallagher, Richard E.
1975-01-01
The National Institute for Occupational Safety and Health (NIOSH) is attempting to develop total programs of occupational safety and health protection. It has established research criteria and a priority system for evaluating the order of investigating suspect substances or agents based upon the expected gain of the health benefit. (Author/MW)
Identification and Control of Pollution from Salt Water Intrusion.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Water Programs.
This document contains informational guidelines for identifying and evaluating the nature and extent of pollution from salt water intrusion. The intent of these guidelines is to provide a basic framework for assessing salt water intrusion problems and their relationship to the total hydrologic system, and to provide assistance in developing…
A new humane method of stunning broilers using low atmospheric pressure
USDA-ARS?s Scientific Manuscript database
This research project evaluated an alternative method of controlled atmosphere stunning of commercial broilers to induce anoxia utilizing a vacuum pump to reduce the oxygen tension, low atmospheric pressure stun (LAPS). A custom built 2 cage-module system (holding a total of 600 broilers each) with...
Traffic Management Coordinator Evaluation of the Dynamic Weather Routes Concept and System
NASA Technical Reports Server (NTRS)
Gong, Chester
2014-01-01
Dynamic Weather Routes (DWR) is a weather-avoidance system for airline dispatchers and FAA traffic managers that continually searches for and advises the user of more efficient routes around convective weather. NASA and American Airlines (AA) have been conducting an operational trial of DWR since July 17, 2012. The objective of this evaluation is to assess DWR from a traffic management coordinator (TMC) perspective, using recently retired TMCs and actual DWR reroutes advisories that were rated acceptable by AA during the operational trial. Results from the evaluation showed that the primary reasons for a TMC to modify or reject airline reroute requests were related to airspace configuration. Approximately 80 percent of the reroutes evaluated required some coordination before implementation. Analysis showed TMCs approved 62 percent of the requested DWR reroutes, resulting in 57 percent of the total requested DWR time savings.
IDEAS: A multidisciplinary computer-aided conceptual design system for spacecraft
NASA Technical Reports Server (NTRS)
Ferebee, M. J., Jr.
1984-01-01
During the conceptual development of advanced aerospace vehicles, many compromises must be considered to balance economy and performance of the total system. Subsystem tradeoffs may need to be made in order to satisfy system-sensitive attributes. Due to the increasingly complex nature of aerospace systems, these trade studies have become more difficult and time-consuming to complete and involve interactions of ever-larger numbers of subsystems, components, and performance parameters. The current advances of computer-aided synthesis, modeling and analysis techniques have greatly helped in the evaluation of competing design concepts. Langley Research Center's Space Systems Division is currently engaged in trade studies for a variety of systems which include advanced ground-launched space transportation systems, space-based orbital transfer vehicles, large space antenna concepts and space stations. The need for engineering analysis tools to aid in the rapid synthesis and evaluation of spacecraft has led to the development of the Interactive Design and Evaluation of Advanced Spacecraft (IDEAS) computer-aided design system. The ADEAS system has been used to perform trade studies of competing technologies and requirements in order to pinpoint possible beneficial areas for research and development. IDEAS is presented as a multidisciplinary tool for the analysis of advanced space systems. Capabilities range from model generation and structural and thermal analysis to subsystem synthesis and performance analysis.
The effect of total noise on two-dimension OCDMA codes
NASA Astrophysics Data System (ADS)
Dulaimi, Layth A. Khalil Al; Badlishah Ahmed, R.; Yaakob, Naimah; Aljunid, Syed A.; Matem, Rima
2017-11-01
In this research, we evaluate the performance of total noise effect on two dimension (2-D) optical code-division multiple access (OCDMA) performance systems using 2-D Modified Double Weight MDW under various link parameters. The impact of the multi-access interference (MAI) and other noise effect on the system performance. The 2-D MDW is compared mathematically with other codes which use similar techniques. We analyzed and optimized the data rate and effective receive power. The performance and optimization of MDW code in OCDMA system are reported, the bit error rate (BER) can be significantly improved when the 2-D MDW code desired parameters are selected especially the cross correlation properties. It reduces the MAI in the system compensate BER and phase-induced intensity noise (PIIN) in incoherent OCDMA The analysis permits a thorough understanding of PIIN, shot and thermal noises impact on 2-D MDW OCDMA system performance. PIIN is the main noise factor in the OCDMA network.
Two low-dose levonorgestrel intrauterine contraceptive systems: a randomized controlled trial.
Nelson, Anita; Apter, Dan; Hauck, Brian; Schmelter, Thomas; Rybowski, Sarah; Rosen, Kimberly; Gemzell-Danielsson, Kristina
2013-12-01
To evaluate the efficacy and safety of two low-dose levonorgestrel intrauterine contraceptive systems. Nulliparous and parous women aged 18-35 years with regular menstrual cycles (21-35 days) requesting contraception were randomized to 3 years of treatment with one of two levonorgestrel intrauterine contraceptive systems: 13.5 mg total content or 19.5 mg total content. The primary outcome was the pregnancy rate, calculated as the Pearl Index. Overall, 1,432 and 1,452 women in the 13.5 mg intrauterine contraceptive system and 19.5 mg intrauterine contraceptive system groups, respectively, had a placement attempted and were included in the full analysis set to evaluate efficacy and safety. Mean (standard deviation) age was 27.1 (4.8) years; 39.2% were nulliparous. Over the 3-year study period, 0.33 pregnancies per 100 women-years (95% confidence interval [CI] 0.16-0.60) were observed with the 13.5 mg intrauterine contraceptive system compared with 0.31 per 100 women-years (95% CI 0.15-0.57) with the 19.5 mg intrauterine contraceptive system. Kaplan-Meier estimates for that period were 0.009 and 0.010, respectively. At least partial expulsions occurred in 4.56% and 3.58% and discontinuation rates resulting from a reported adverse event occurred in 21.9% and 19.1%, respectively. Ten of the 20 pregnancies were ectopic. Serious adverse events included six cases of pelvic inflammatory disease and one partial uterine perforation. Both lower-dose levonorgestrel intrauterine contraceptive systems were highly effective for 3 years of use and generally well tolerated. ClinicalTrials.gov, www.clinicaltrials.gov, NCT00528112. : I.
Aberer, Werner; Kränke, Birger
2002-11-30
The determination of IgE antibodies is important for the in vitro diagnosis of allergic diseases. However, not all systems currently available in the market fulfill essential quality criteria, e.g. regarding characteristics such as sensitivity and specificity, and the data do not always reflect true clinical relevance in the required fashion. Recent innovations may reduce the workload for the technician, and thus help save time and money. More importantly, they might reduce potential sources of error. Two allergy systems, the well established Pharmacia CAP system that uses the allergens conventionally in a solid phase and the ALLERgen system that employs liquid allergens, were compared with regard to quality criteria and practicability. Defined serum pools were checked for within-run and between-days imprecision of IgE antibody detection in two independent laboratories. Serum specimens from allergic patients and controls were tested in parallel using both methods for total and antigen-specific IgE antibody detection under standardized conditions. In addition, one laboratory working exclusively with the ALLERgen system participated in the Austrian inter-laboratory quality assessment program. The two systems were comparable in terms of sensitivity and specificity, and also showed good correlation. Within-run evaluations were excellent for total IgE and antigen-specific IgE, and the between-days imprecision was satisfactory. Coefficients of variation were within an acceptable range for the different groups of allergens. In the external quality control program the data obtained with the ALLERgen system showed good concordance with other systems in use; up to 94% of the results were identical when considering clinically relevant sensitizations. Regarding practicability, both systems were most satisfactory for the operator. The ALLERgen system offered a certain advantage in terms of automated operation, which resulted in shorter fixed and variable phases of personnel time. Both the Pharmacia CAP system and the ALLERgen system belong to an advanced generation of allergy test systems and are easy to handle. The reproducibility of results is good with both methods, and the imprecision data fall within an acceptable range. Thus, the ALLERgen system is a reliable in vitro system for evaluating specific and total IgE in serum, providing data equivalent to those obtained with the CAP system.
NASA Astrophysics Data System (ADS)
Marguí, Eva; Hidalgo, Manuela; Migliori, Alessandro; Leani, Juan José; Queralt, Ignasi; Kallithrakas-Kontos, Nikolaos; Streli, Christina; Prost, Josef; Karydas, Andreas Germanos
2018-07-01
The aim of the work is to present a systematic evaluation of the analytical capabilities of the new X-ray fluorescence facility jointly operated between the International Atomic Energy Agency and the Elettra Sincrotrone Trieste for multipurpose total reflection X-ray fluorescence analysis. The analytical performance of the XRF beamline end-station (IAEAXspe) was systematically evaluated under TXRF excitation geometry by analyzing different types of aqueous (lake, waste and fresh water) and solid (soil, vegetal, biological) certified reference materials using an excitation energy of 13.0 keV (for the purpose of multielemental analysis). The results obtained for both types of samples in terms of limits of detection and accuracy were also compared with those obtained using laboratory X-ray tube based TXRF systems with different features (including Mo and W X-ray tube systems). Taking advantage of the possibility to work under high vacuum, the IAEAXspe set-up instrumental sensitivity was also determined using an excitation energy of 6.2 keV to explore the possibilities for light elements determination. A clear improvement of the element detection limits is achieved when comparing this facility to conventional X-ray tube based TXRF systems highlighting the benefits of using the monoenergetic synchrotron exciting radiation and the ultra-high vacuum chamber in comparison with conventional laboratory systems. The results of the present work are discussed in view of further exploitation of the facility for different environmental and biological related applications.
Güzel, Yunus; Golge, Umut H; Goksel, Ferdi; Vural, Ahmet; Akcay, Muruvvet; Elmas, Sait; Turkon, Hakan; Unver, Ahmet
2016-10-01
We explored the ability of local and systemic applications of boric acid (BA) to reduce the numbers of methicillin-resistant Staphylococcus aureus (MRSA) in a rat model of tibial osteomyelitis (OM), and compared boric acid with vancomycin (V). Implant-associated osteomyelitis was established in 35 rats. After 4 weeks, at which time OM was evident both radiologically and serologically in all animals, the rats were divided into five groups of equal number: group 1, control group (no local application of BA or other medication); group 2, V group; group 3, local BA + V group; group 4, local BA group; and group 5, local + systemic BA group. Serum total antioxidant status, and the levels of tumor necrosis factor (TNF)-α and interleukin (IL)-6, were measured. Pathological changes attributable to bone OM were evaluated using a grading system. Bacterial colony-forming units (CFUs) per gram of bone were counted. The lowest bacterial numbers were evident in group 3, and the bacterial numbers were significantly lower than that of the control group in all four test groups (p < 0.001). Group 3 also had the least severe bone infection (OM score 1.7 ± 1.1, p < 0.05). Upon histological and microbiological evaluation, no significant difference was evident between groups 2 and 3. Total antioxidant levels were significantly different in all treatment groups compared to the control group. Microbiological and histopathological evaluation showed that systemic or local application of BA was effective to treat OM, although supplementary V increased the effectiveness of BA.
Performance of electrolyte measurements assessed by a trueness verification program.
Ge, Menglei; Zhao, Haijian; Yan, Ying; Zhang, Tianjiao; Zeng, Jie; Zhou, Weiyan; Wang, Yufei; Meng, Qinghui; Zhang, Chuanbao
2016-08-01
In this study, we analyzed frozen sera with known commutabilities for standardization of serum electrolyte measurements in China. Fresh frozen sera were sent to 187 clinical laboratories in China for measurement of four electrolytes (sodium, potassium, calcium, and magnesium). Target values were assigned by two reference laboratories. Precision (CV), trueness (bias), and accuracy [total error (TEa)] were used to evaluate measurement performance, and the tolerance limit derived from the biological variation was used as the evaluation criterion. About half of the laboratories used a homogeneous system (same manufacturer for instrument, reagent and calibrator) for calcium and magnesium measurement, and more than 80% of laboratories used a homogeneous system for sodium and potassium measurement. More laboratories met the tolerance limit of imprecision (coefficient of variation [CVa]) than the tolerance limits of trueness (biasa) and TEa. For sodium, calcium, and magnesium, the minimal performance criterion derived from biological variation was used, and the pass rates for total error were approximately equal to the bias (<50%). For potassium, the pass rates for CV and TE were more than 90%. Compared with the non homogeneous system, the homogeneous system was superior for all three quality specifications. The use of commutable proficiency testing/external quality assessment (PT/EQA) samples with values assigned by reference methods can monitor performance and provide reliable data for improving the performance of laboratory electrolyte measurement. The homogeneous systems were superior to the non homogeneous systems, whereas accuracy of assigned values of calibrators and assay stability remained challenges.
2014-01-01
Background To validate the association between accommodation and visual asthenopia by measuring objective accommodative amplitude with the Optical Quality Analysis System (OQAS®, Visiometrics, Terrassa, Spain), and to investigate associations among accommodation, ocular surface instability, and visual asthenopia while viewing 3D displays. Methods Fifteen normal adults without any ocular disease or surgical history watched the same 3D and 2D displays for 30 minutes. Accommodative ability, ocular protection index (OPI), and total ocular symptom scores were evaluated before and after viewing the 3D and 2D displays. Accommodative ability was evaluated by the near point of accommodation (NPA) and OQAS to ensure reliability. The OPI was calculated by dividing the tear breakup time (TBUT) by the interblink interval (IBI). The changes in accommodative ability, OPI, and total ocular symptom scores after viewing 3D and 2D displays were evaluated. Results Accommodative ability evaluated by NPA and OQAS, OPI, and total ocular symptom scores changed significantly after 3D viewing (p = 0.005, 0.003, 0.006, and 0.003, respectively), but yielded no difference after 2D viewing. The objective measurement by OQAS verified the decrease of accommodative ability while viewing 3D displays. The change of NPA, OPI, and total ocular symptom scores after 3D viewing had a significant correlation (p < 0.05), implying direct associations among these factors. Conclusions The decrease of accommodative ability after 3D viewing was validated by both subjective and objective methods in our study. Further, the deterioration of accommodative ability and ocular surface stability may be causative factors of visual asthenopia in individuals viewing 3D displays. PMID:24612686
Objective image analysis of the meibomian gland area.
Arita, Reiko; Suehiro, Jun; Haraguchi, Tsuyoshi; Shirakawa, Rika; Tokoro, Hideaki; Amano, Shiro
2014-06-01
To evaluate objectively the meibomian gland area using newly developed software for non-invasive meibography. Eighty eyelids of 42 patients without meibomian gland loss (meiboscore=0), 105 eyelids of 57 patients with loss of less than one-third total meibomian gland area (meiboscore=1), 13 eyelids of 11 patients with between one-third and two-thirds loss of meibomian gland area (meiboscore=2) and 20 eyelids of 14 patients with two-thirds loss of meibomian gland area (meiboscore=3) were studied. Lid borders were automatically determined. The software evaluated the distribution of the luminance and, by enhancing the contrast and reducing image noise, the meibomian gland area was automatically discriminated. The software calculated the ratio of the total meibomian gland area relative to the total analysis area in all subjects. Repeatability of the software was also evaluated. The mean ratio of the meibomian gland area to the total analysis area in the upper/lower eyelids was 51.9±5.7%/54.7±5.4% in subjects with a meiboscore of 0, 47.7±6.0%/51.5±5.4% in those with a meiboscore of 1, 32.0±4.4%/37.2±3.5% in those with a meiboscore of 2 and 16.7±6.4%/19.5±5.8% in subjects with a meiboscore of 3. The meibomian gland area was objectively evaluated using the developed software. This system could be useful for objectively evaluating the effect of treatment on meibomian gland dysfunction. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Juneja, Pankaj; Shivaprakash, G; Chopra, S S; Kambalyal, P B
2015-12-01
Although a number of studies have been undertaken to evaluate the friction characteristics of self-ligating brackets, there have been only few studies which have actually evaluated the clinical efficiency of these self-ligating brackets. This study was done to evaluate the clinical efficiency of Passive SLB (Smart Clip) in terms of anchorage loss and total treatment duration by comparing it with a Conventional pre-adjusted edgewise (M.B.T.) bracket system. This was a retrospective study in which the study sample comprised of ten patients treated with Passive SLB (Smart Clip, 0.022″) and ten patients treated with Conventional pre-adjusted edgewise (M.B.T.) bracket system (0.022″) who required therapeutic extraction of U/L first premolars as a part of their orthodontic treatment plan. Pretreatment and post treatment lateral cephalograms were taken to evaluate the amount of anchorage loss. The total time required to complete the treatment was also recorded. Anchorage loss observed with Passive SLB (Smart Clip) sagittally was 1.90 ± 0.68 mm in the maxilla and 1.90 ± 0.43 mm in the mandible and vertically was 0.52 ± 0.53 mm in the maxilla and 0.70 ± 0.69 mm in the mandible. Anchorage loss observed with Conventional pre-adjusted edgewise (M.B.T.) bracket system sagittally was 2.08 ± 0.43 mm in the maxilla and 1.95 ± 0.44 mm in the mandible and vertically was 0.50 ± 0.49 mm in the maxilla and 0.68 ± 0.53 mm in the mandible. The average time taken for the completion of treatment in Passive SLB (Smart Clip) and Conventional pre-adjusted edgewise (M.B.T.) bracket system was 14.0 ± 2.4 and 17.2 ± 2.6 months respectively. There was no statistically significant difference in the quantum of anchor loss between Smart Clip self-ligating bracket system and Conventional pre-adjusted edgewise (M.B.T.) bracket system although Smart Clip self-ligating bracket system is efficient in reducing the overall treatment time.
Juneja, Pankaj; Shivaprakash, G.; Chopra, S.S.; Kambalyal, P.B.
2015-01-01
Background Although a number of studies have been undertaken to evaluate the friction characteristics of self-ligating brackets, there have been only few studies which have actually evaluated the clinical efficiency of these self-ligating brackets. This study was done to evaluate the clinical efficiency of Passive SLB (Smart Clip) in terms of anchorage loss and total treatment duration by comparing it with a Conventional pre-adjusted edgewise (M.B.T.) bracket system. Methods This was a retrospective study in which the study sample comprised of ten patients treated with Passive SLB (Smart Clip, 0.022″) and ten patients treated with Conventional pre-adjusted edgewise (M.B.T.) bracket system (0.022″) who required therapeutic extraction of U/L first premolars as a part of their orthodontic treatment plan. Pretreatment and post treatment lateral cephalograms were taken to evaluate the amount of anchorage loss. The total time required to complete the treatment was also recorded. Results Anchorage loss observed with Passive SLB (Smart Clip) sagittally was 1.90 ± 0.68 mm in the maxilla and 1.90 ± 0.43 mm in the mandible and vertically was 0.52 ± 0.53 mm in the maxilla and 0.70 ± 0.69 mm in the mandible. Anchorage loss observed with Conventional pre-adjusted edgewise (M.B.T.) bracket system sagittally was 2.08 ± 0.43 mm in the maxilla and 1.95 ± 0.44 mm in the mandible and vertically was 0.50 ± 0.49 mm in the maxilla and 0.68 ± 0.53 mm in the mandible. The average time taken for the completion of treatment in Passive SLB (Smart Clip) and Conventional pre-adjusted edgewise (M.B.T.) bracket system was 14.0 ± 2.4 and 17.2 ± 2.6 months respectively. Conclusion There was no statistically significant difference in the quantum of anchor loss between Smart Clip self-ligating bracket system and Conventional pre-adjusted edgewise (M.B.T.) bracket system although Smart Clip self-ligating bracket system is efficient in reducing the overall treatment time. PMID:26843751
Pfaendler, Krista S.; Mwanahamuntu, Mulindi H.; Sahasrabuddhe, Vikrant V.; Mudenda, Victor; Stringer, Jeffrey S.A.; Parham, Groesbeck P.
2009-01-01
Objective We demonstrate the feasibility of implementing a referral and management system for cryotherapy-ineligible women in a “screen-and-treat” cervical cancer prevention program targeting HIV-infected women in Zambia. Methods We established criteria for patient referral, developed a training program for loop electrosurgical excision procedure (LEEP) providers, and adapted LEEP to a resource-constrained setting. Results We successfully trained 15 nurses to perform visual inspection with acetic acid (VIA) followed by immediate cryotherapy. Women with positive tests but ineligible for cryotherapy were referred for further evaluation. We trained four Zambian physicians to evaluate referrals, perform punch biopsy, LEEP, and manage intra-operative and post-operative complications. From January 2006 through October 2007, a total of 8823 women (41.5% HIV seropositive) were evaluated by nurses in outlying prevention clinics; of these, 1477 (16.7%) were referred for physician evaluation based on established criteria. Of the 875 (59.2% of 1147 referred) that presented for evaluation, 748 (8.4% of total screened) underwent histologic evaluation in the form of punch biopsy or LEEP. Complications associated with LEEP included anesthesia reaction (n=2) which spontaneously resolved, intra-operative (n=12) and post-operative (n=2) bleeding managed by local measures, and post-operative infection (n=12) managed with antibiotics. Conclusion With adaptations for a resource-constrained environment, we have demonstrated that performing LEEP is feasible and safe, with low rates of complications that can be managed locally. It is important to establish referral and management systems using LEEP-based excisional evaluation for women with cryotherapy-ineligible lesions in VIA-based “screen-and-treat” protocols nested within HIV-care programs in resource-constrained settings. PMID:18556050
Pfaendler, Krista S; Mwanahamuntu, Mulindi H; Sahasrabuddhe, Vikrant V; Mudenda, Victor; Stringer, Jeffrey S A; Parham, Groesbeck P
2008-09-01
We demonstrate the feasibility of implementing a referral and management system for cryotherapy-ineligible women in a "screen-and-treat" cervical cancer prevention program targeting HIV-infected women in Zambia. We established criteria for patient referral, developed a training program for loop electrosurgical excision procedure (LEEP) providers, and adapted LEEP to a resource-constrained setting. We successfully trained 15 nurses to perform visual inspection with acetic acid (VIA) followed by immediate cryotherapy. Women with positive tests but ineligible for cryotherapy were referred for further evaluation. We trained four Zambian physicians to evaluate referrals, perform punch biopsy, LEEP, and manage intra-operative and post-operative complications. From January 2006 through October 2007, a total of 8823 women (41.5% HIV seropositive) were evaluated by nurses in outlying prevention clinics; of these, 1477 (16.7%) were referred for physician evaluation based on established criteria. Of the 875 (59.2% of 1147 referred) that presented for evaluation, 748 (8.4% of total screened) underwent histologic evaluation in the form of punch biopsy or LEEP. Complications associated with LEEP included anesthesia reaction (n=2) which spontaneously resolved, intra-operative (n=12) and post-operative (n=2) bleeding managed by local measures, and post-operative infection (n=12) managed with antibiotics. With adaptations for a resource-constrained environment, we have demonstrated that performing LEEP is feasible and safe, with low rates of complications that can be managed locally. It is important to establish referral and management systems using LEEP-based excisional evaluation for women with cryotherapy-ineligible lesions in VIA-based "screen-and-treat" protocols nested within HIV-care programs in resource-constrained settings.
A system performance throughput model applicable to advanced manned telescience systems
NASA Technical Reports Server (NTRS)
Haines, Richard F.
1990-01-01
As automated space systems become more complex, autonomous, and opaque to the flight crew, it becomes increasingly difficult to determine whether the total system is performing as it should. Some of the complex and interrelated human performance measurement issues are addressed that are related to total system validation. An evaluative throughput model is presented which can be used to generate a human operator-related benchmark or figure of merit for a given system which involves humans at the input and output ends as well as other automated intelligent agents. The concept of sustained and accurate command/control data information transfer is introduced. The first two input parameters of the model involve nominal and off-nominal predicted events. The first of these calls for a detailed task analysis while the second is for a contingency event assessment. The last two required input parameters involving actual (measured) events, namely human performance and continuous semi-automated system performance. An expression combining these four parameters was found using digital simulations and identical, representative, random data to yield the smallest variance.
Evaluation of the MIT RMID 1000 system for the identification of Listeria species.
Ricardi, John; Haavig, David; Cruz, Lasaunta; Paoli, George; Gehring, Andrew
2010-01-01
The Micro Imaging Technology (MIT) 1000 Rapid Microbial Identification (RMID) System is a device that uses the principles of light scattering coupled with proprietary algorithms to identify bacteria after being cultured and placed in a vial of filtered water. This specific method is for pure culture identification of Listeria spp. A total of 81 microorganisms (55 isolates) were tested by the MIT 1000 System, of which 25 were Listeria spp. and 30 a variety of other bacterial species. In addition, a total of 406 tests over seven different ruggedness parameters were tested by the MIT 1000 System to determine its flexibility to the specifications stated in the MIT 1000 System User Guide in areas where they might be deviated by a user to shorten the test cycle. Overall, MIT concluded that the MIT 1000 System had an accuracy performance that should certify this Performance Test Method for the identification of Listeria spp. This report discusses the tests performed, results achieved, and conclusions, along with several reference documents to enable a higher understanding of the technology used by the MIT 1000 System.
Oxidative Stress and Antioxidant System in Periodontitis
Wang, Yue; Andrukhov, Oleh; Rausch-Fan, Xiaohui
2017-01-01
Periodontitis is a common inflammatory disease, which is initiated by bacterial infection and subsequently progressed by aberrant host response. It can result in the destruction of teeth supporting tissues and have an influence on systemic health. When periodontitis occurs, reactive oxygen species, which are overproduced mostly by hyperactive neutrophils, could not be balanced by antioxidant defense system and cause tissues damage. This is characterized by increased metabolites of lipid peroxidation, DNA damage and protein damage. Local and systemic activities of antioxidants can also be influenced by periodontitis. Total antioxidant capacity, total oxidant status and oxidative stress index have been used to evaluate the oxidative stress associated with periodontitis. Studies have confirmed that inflammatory response in periodontitis is associated with an increased local and systemic oxidative stress and compromised antioxidant capacity. Our review focuses on increased oxidative stress in periodontal disease, specifically, on the relationship between the local and systemic biomarkers of oxidative stress and periodontitis and their association with the pathogenesis of periodontitis. Also, the relationship between periodontitis and systemic inflammation, and the effects of periodontal therapy on oxidative stress parameters will be discussed. PMID:29180965
A classification of freshwater Louisiana lakes based on water quality and user perception data.
Burden, D G; Malone, R F
1987-09-01
An index system developed for Louisiana lakes was based on correlations between measurable water quality parameters and perceived lake quality. Support data was provided by an extensive monitoring program of 30 lakes coordinated with opinion surveys undertaken during summer 1984. Lakes included in the survey ranged from 4 to 735 km(2) in surface area with mean depths ranging from 0.5 to 8.0 m. Water quality data indicated most of these lakes are eutrophic, although many have productive fisheries and are considered recreational assets. Perception ratings of fishing quality and its associated water quality were obtained by distributing approximately 1200 surveys to Louisiana Bass Club Associaton members. The ability of Secchi disc transparency, total organic carbon, total Kjeldahl nitrogen, total phosphorus, and chlorophyll a to discriminate between perception classes was examined using probability distributions and multivariate analyses. Secchi disc and total organic carbon best reflected perceived lake conditions; however, these parameters did not provide the discrimination necessary for developing a quantitative risk assessment of lake trophic state. Consequently, an interim lakes index system was developed based on total organic carbon and perceived lake conditions. The developed index system will aid State officials in interpretating and evaluating regularly collected lake quality data, recognizing potential problem areas, and identifying proper management policies for protecting fisheries usage within the State.
Evaluation of computing systems using functionals of a Stochastic process
NASA Technical Reports Server (NTRS)
Meyer, J. F.; Wu, L. T.
1980-01-01
An intermediate model was used to represent the probabilistic nature of a total system at a level which is higher than the base model and thus closer to the performance variable. A class of intermediate models, which are generally referred to as functionals of a Markov process, were considered. A closed form solution of performability for the case where performance is identified with the minimum value of a functional was developed.
2017-01-04
you have normal pulmonary function? YES NO 6. Have you ever been diagnosed with heart /circulatory disease ? YES NO 7. Do you...total dropout, the Canary system occasionally exhibited long stretches of data with sporadic heart rate signal dropout accompanied by high variance...values as low as 86%. This occurs over a timespan with sporadic heart rate signal dropout and greater mismatch between Canary and Ohmeda HR
Analyses and tests of the B-1 aircraft structural mode control system
NASA Technical Reports Server (NTRS)
Wykes, J. H.; Byar, T. R.; Macmiller, C. J.; Greek, D. C.
1980-01-01
Analyses and flight tests of the B-1 structural mode control system (SMCS) are presented. Improvements in the total dynamic response of a flexible aircraft and the benefits to ride qualities, handling qualities, crew efficiency, and reduced dynamic loads on the primary structures, were investigated. The effectiveness and the performance of the SMCS, which uses small aerodynamic surfaces at the vehicle nose to provide damping to the structural modes, were evaluated.
NASA Technical Reports Server (NTRS)
Summers, Geoffrey P.; Walters, Robert J.; Messenger, Scott R.; Burke, Edward A.
1996-01-01
An analysis embodied in a PC computer program is presented, which quantitatively demonstrates how the availability of radiation hard solar cells can help minimize the cost of a global satellite communications system. An important distinction between the currently proposed systems, such as Iridium, Odyssey and Ellipsat, is the number of satellites employed and their operating altitudes. Analysis of the major costs associated with implementing these systems shows that operation at orbital altitudes within the earth's radiation belts (10(exp 3) to 10(exp 4)km) can reduce the total cost of a system by several hundred percent, so long as radiation hard components including solar cells can be used. A detailed evaluation of the predicted performance of photovoltaic arrays using several different planar solar cell technologies is given, including commercially available Si and GaAs/Ge, and InP/Si which is currently under development. Several examples of applying the program are given, which show that the end of life (EOL) power density of different technologies can vary by a factor of ten for certain missions. Therefore, although a relatively radiation-soft technology can usually provide the required EOL power by simply increasing the size of the array, the impact upon the total system budget could be unacceptable, due to increased launch and hardware costs. In aggregate, these factors can account for more than a 10% increase in the total system cost. Since the estimated total costs of proposed global-coverage systems range from $1B to $9B, the availability of radiation-hard solar cells could make a decisive difference in the selection of a particular constellation architecture.
In vitro evaluation of free radical scavenging activity of Codariocalyx motorius root extract.
Chidambaram, Uma; Pachamuthu, Vanitha; Natarajan, Suganya; Elango, Bhakkiyalakshmi; Suriyanarayanan; Ramkumar, Kunga Mohan
2013-03-01
To determine the phenolic content in Codariocalyx motorius root extract and to evaluate its antioxidant properties using various in vitro assay systems. The antioxidant activity was evaluated based on scavenging of 1,1-diphenyl-2-picrylhydrazyl, hydroxyl radicals, superoxide anions, nitric oxide, hydrogen peroxide, peroxynitrite, reducing power and by inhibition of lipid peroxidation which was estimated in terms of thiobarbituric acid reactive substances. The root extract of the Codariocalyx motorius (C. motorius) exhibited potent total antioxidant activity that increased with increasing amount of extract concentration, which was compared with standard drug such as quercetin, butylated hydroxytoluene, tocopherol at different concentrations. The different concentrations of the extracts showed inhibition on lipid peroxidation. In addition, the extracts had effective reducing power, free radical scavenging, super oxide anion scavenging, nitric oxide scavenging, lipid peroxidation, and total phenolic content depending on concentration. High correlation between total phenolic contents and scavenging potential of different reactive oxygen species (r(2)=0.831-0.978) indicated the polyphenols as the main antioxidants. Codariocalyx motorius (C. motorius) root possess the highly active antioxidant substance which can be used for the treatment of oxidative stress-related diseases. Copyright © 2013 Hainan Medical College. Published by Elsevier B.V. All rights reserved.
Dagar, S S; Singh, N; Goel, N; Kumar, S; Puniya, A K
2015-01-01
In the present study, rumen microbial groups, i.e. total rumen microbes (TRM), total anaerobic fungi (TAF), avicel enriched bacteria (AEB) and neutral detergent fibre enriched bacteria (NEB) were evaluated for wheat straw (WS) degradability and different fermentation parameters in vitro. Highest WS degradation was shown for TRM, followed by TAF, NEB and least by AEB. Similar patterns were observed with total gas production and short chain fatty acid profiles. Overall, TAF emerged as the most potent individual microbial group. In order to enhance the fibrolytic and rumen fermentation potential of TAF, we evaluated 18 plant feed additives in vitro. Among these, six plant additives namely Albizia lebbeck, Alstonia scholaris, Bacopa monnieri, Lawsonia inermis, Psidium guajava and Terminalia arjuna considerably improved WS degradation by TAF. Further evaluation showed A. lebbeck as best feed additive. The study revealed that TAF plays a significant role in WS degradation and their fibrolytic activities can be improved by inclusion of A. lebbeck in fermentation medium. Further studies are warranted to elucidate its active constituents, effect on fungal population and in vivo potential in animal system.
NASA Technical Reports Server (NTRS)
Corban, Robert
1993-01-01
The systems engineering process for the concept definition phase of the program involves requirements definition, system definition, and consistent concept definition. The requirements definition process involves obtaining a complete understanding of the system requirements based on customer needs, mission scenarios, and nuclear thermal propulsion (NTP) operating characteristics. A system functional analysis is performed to provide a comprehensive traceability and verification of top-level requirements down to detailed system specifications and provides significant insight into the measures of system effectiveness to be utilized in system evaluation. The second key element in the process is the definition of system concepts to meet the requirements. This part of the process involves engine system and reactor contractor teams to develop alternative NTP system concepts that can be evaluated against specific attributes, as well as a reference configuration against which to compare system benefits and merits. Quality function deployment (QFD), as an excellent tool within Total Quality Management (TQM) techniques, can provide the required structure and provide a link to the voice of the customer in establishing critical system qualities and their relationships. The third element of the process is the consistent performance comparison. The comparison process involves validating developed concept data and quantifying system merits through analysis, computer modeling, simulation, and rapid prototyping of the proposed high risk NTP subsystems. The maximum amount possible of quantitative data will be developed and/or validated to be utilized in the QFD evaluation matrix. If upon evaluation of a new concept or its associated subsystems determine to have substantial merit, those features will be incorporated into the reference configuration for subsequent system definition and comparison efforts.
Groundwater transport of strontium 90 in a glacial outwash environment
Kipp, Kenneth L.; Stollenwerk, Kenneth G.; Grove, David B.
1986-01-01
As part of the investigation of groundwater contamination at a uranium-scrap recovery plant at Wood River Junction, Rhode Island, laboratory experiments led to the development of a model for predicting the transport of strontium 90 in glacial outwash sediments based on an approximate mechanism for ion exchange. The multicomponent system was simplified to two components by regarding all exchangeable cations other than strontium 90 as a single component. The binary ion-exchange parameter was a function of the variable, total ion concentration. A one-dimensional solute transport model was formulated to evaluate the time necessary for natural groundwater flow to remove the strontium 90 contamination plume from the groundwater system to the Pawcatuck River. The finite difference transport equations were solved sequentially for total ion concentrations, then strontium 90 concentrations. Clay-free quartz and feldspar sands at the study site have little potential for strontium 90 sorption, and high calcium, magnesium, and sodium concentrations compete for the few ion exchange sites. As the total ion concentration plume moves out of the system, ion exchange of strontium 90 increases, reducing the strontium 90 concentration in the groundwater. Cleanout times predicted using the binary ion exchange mechanism were about two thirds of those predicted using a constant distribution coefficient. It is suggested that this type of model can simulate solute transport more realistically in many groundwater systems where the total ion concentration is not constant.
Aparicio, C
1994-10-01
To maintain osseointegration, it is essential that the prosthesis fit with total passivity because the absence of a periodontal ligament makes the implant unable to adapt its position to a nonpassive framework. The traditional system of building a metal framework by melting over mechanized pieces--called gold cylinders in the Brånemark system--has been modified so these pieces are joined to the metal framework by means of physicochemical bonding. This bond is achieved by treating the metallic surfaces with a Silicoater system and a composite resin cement that sets in the mouth using an improved cementing protocol. In this paper, the clinical viability of this new philosophy, shown over 2 years, is presented. A total of 64 prostheses (39 maxillary and 25 mandibular) supported by 214 abutments, with an average observation period of 9 months, were evaluated. The results show that it is possible to routinely obtain a ceramometal prosthesis with a totally passive circular fitting while maintaining the possibility of retrieval, thus making postceramic soldering unnecessary.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beshr, Mohamed; Aute, Vikrant; Abdelaziz, Omar
Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system s Life Cycle Climate Performance (LCCP) was presented as a comprehensive metric with the aim of calculating the equivalent mass of carbon dioxide released into the atmosphere throughout its lifetime, from construction to operation and destruction. In this paper, an open source tool for the evaluation of the LCCPmore » of different air-conditioning and refrigeration systems is presented and used to compare the environmental impact of a typical multiplex direct expansion (DX) supermarket refrigeration systems based on three different refrigerants as follows: two hydrofluorocarbon (HFC) refrigerants (R-404A, and R-407F), and a low global warming potential (GWP) refrigerant (N-40). The comparison is performed in 8 US cities representing different climates. The hourly energy consumption of the refrigeration system, required for the calculation of the indirect emissions, is calculated using a widely used building energy modeling tool (EnergyPlus). A sensitivity analysis is performed to determine the impact of system charge and power plant emission factor on the LCCP results. Finally, we performed an uncertainty analysis to determine the uncertainty in total emissions for both R-404A and N-40 operated systems. We found that using low GWP refrigerants causes a considerable drop in the impact of uncertainty in the inputs related to direct emissions on the uncertainty of the total emissions of the system.« less
In Vitro Evaluation of the Fresenius Kabi CATSmart Autotransfusion System.
Alberts, Melissa; Groom, Robert C; Walczak, Richard; Kramer, Robert; Karpiel, Adrienne; Dieter, Jeanette; Sheth, Lisa; Greene, Nathaniel H; Jooste, Edmund H
2017-06-01
Use of autotransfusion systems to collect, wash, and concentrate shed blood during surgical procedures is a widely used method for reducing postoperative anemia and the need for blood transfusions. The aim of this study was to evaluate the CATSmart Continuous Autotransfusion System wash program performance with small (200 or 700 mL) and large volumes (1,000 mL) of shed blood and to determine non-inferiority of the CATSmart to the C.A.T.S plus system. Human whole blood was collected in citrate phosphate dextrose, diluted, and divided into two aliquots to be processed as a pair using the C.A.T.S plus and CATSmart systems with their corresponding wash programs: low-volume, high quality/smart, or emergency wash. Final packed red cell product was analyzed for red blood cell (RBC), white blood cell, and platelet counts; hemoglobin; hemolysis; RBC recovery rates; and elimination of albumin, total protein, and potassium. The mean hematocrit (HCT) after processing with CATSmart and C.A.T.S plus systems were 59.63% and 57.71%, respectively. The calculated overall RBC recovery rates on the CATSmart and C.A.T.S plus systems were 85.41% and 84.99%, respectively. Elimination of albumin (97.5%, 98.0%), total proteins (97.1%, 97.5%), and potassium (92.1%, 91.9%) were also calculated for the CATSmart and C.A.T.S plus systems. The CATSmart and C.A.T.S plus systems both provided a high-quality product in terms of HCT, protein elimination, and hemolysis rates across the range of tested shed blood volumes and all wash programs. The study was able to confirm the CATSmart is non-inferior to the C.A.T.S plus system.
In Vitro Evaluation of the Fresenius Kabi CATSmart Autotransfusion System
Alberts, Melissa; Groom, Robert C.; Walczak, Richard; Kramer, Robert; Karpiel, Adrienne; Dieter, Jeanette; Sheth, Lisa; Greene, Nathaniel H.; Jooste, Edmund H.
2017-01-01
Abstract: Use of autotransfusion systems to collect, wash, and concentrate shed blood during surgical procedures is a widely used method for reducing postoperative anemia and the need for blood transfusions. The aim of this study was to evaluate the CATSmart Continuous Autotransfusion System wash program performance with small (200 or 700 mL) and large volumes (1,000 mL) of shed blood and to determine non-inferiority of the CATSmart to the C.A.T.Splus system. Human whole blood was collected in citrate phosphate dextrose, diluted, and divided into two aliquots to be processed as a pair using the C.A.T.Splus and CATSmart systems with their corresponding wash programs: low-volume, high quality/smart, or emergency wash. Final packed red cell product was analyzed for red blood cell (RBC), white blood cell, and platelet counts; hemoglobin; hemolysis; RBC recovery rates; and elimination of albumin, total protein, and potassium. The mean hematocrit (HCT) after processing with CATSmart and C.A.T.Splus systems were 59.63% and 57.71%, respectively. The calculated overall RBC recovery rates on the CATSmart and C.A.T.Splus systems were 85.41% and 84.99%, respectively. Elimination of albumin (97.5%, 98.0%), total proteins (97.1%, 97.5%), and potassium (92.1%, 91.9%) were also calculated for the CATSmart and C.A.T.Splus systems. The CATSmart and C.A.T.Splus systems both provided a high-quality product in terms of HCT, protein elimination, and hemolysis rates across the range of tested shed blood volumes and all wash programs. The study was able to confirm the CATSmart is non-inferior to the C.A.T.Splus system. PMID:28638159
14-year median follow-up using the press-fit condylar sigma design for total knee arthroplasty.
Patil, Shantanu S; Branovacki, George; Martin, Mersadies R; Pulido, Pamela A; Levy, Yadin D; Colwell, Clifford W
2013-09-01
Median 14-year follow-up (mean 11.8 years) of a cemented primary posterior cruciate-retaining total knee arthroplasty (TKA) utilizing the Press-Fit Condylar (PFC) Sigma design was evaluated in 77 patients (79 TKA). Follow-up assessment included implant survivorship, x-rays, Knee Society rating system, and clinical evaluation. Radiographic analysis demonstrated minor non-progressive osteolysis in 40% (10/25) knees. Two revisions, one for instability at 4 years and one for polyethylene wear at 10 years were performed. Survivorship of the PFC Sigma knee implant was 97% using revision for any reason and 100% using aseptic loosening as endpoints. The PFC Sigma had excellent survivorship at 14 years, the longest clinical follow-up reported. Copyright © 2013 Elsevier Inc. All rights reserved.
[Environmental cost of rice production in Dongting Lake area of Hunan Province].
Xiang, Ping'an; Huang, Huang; Yan, Huimin; Zhou, Yan; Zheng, Hua; Huang, Xingguo
2005-11-01
To evaluate the environmental cost of rice production is of significance for the sustainable development of agriculture and the set-up of green GDP accounting system. In this paper, the environmental cost of rice production in Dongting Lake area, one of the main bread baskets in China, was evaluated from the aspects of pesticide pollution, chemical fertilizer pollution, greenhouse gases emission, plastic film persistence, paddyfield gleyization, and polderization. The results showed that in 1999, the total environmental cost of rice production in this area was 41.91 billion yuan, equivalent to 26.8% of its total agricultural production value, or 28.5% of the gross output of its planting industry. For the sustainable production of rice, the strategies for decrease environmental cost intrinsically were put forward.
Proschek, Dirk; Kafchitsas, K.; Rauschmann, M. A.; Kurth, A. A.; Vogl, T. J.
2008-01-01
Interventional procedures are associated with high radiation doses for both patients and surgeons. To reduce the risk from ionizing radiation, it is essential to minimize radiation dose. This prospective study was performed to evaluate the effectiveness in reducing radiation dose during facet joint injection in the lumbar spine and to evaluate the feasibility and possibilities of the new real time image guidance system SabreSource™. A total of 60 patients, treated with a standardized injection therapy of the facet joints L4–L5 or L5–S1, were included in this study. A total of 30 patients were treated by fluoroscopy guidance alone, the following 30 patients were treated using the new SabreSource™ system. Thus a total of 120 injections to the facet joints were performed. Pain, according to the visual analogue scale (VAS), was documented before and 6 h after the intervention. Radiation dose, time of radiation and the number of exposures needed to place the needle were recorded. No significant differences concerning age (mean age 60.5 years, range 51–69), body mass index (mean BMI 26.2, range 22.2–29.9) and preoperative pain (VAS 7.9, range 6–10) were found between the two groups. There was no difference in pain reduction between the two groups (60 vs. 61.5%; P = 0.001) but the radiation dose was significantly smaller with the new SabreSource™ system (reduction of radiation dose 32.7%, P = 0.01; reduction of mean entrance surface dose 32.3%, P = 0.01). The SabreSource™ System significantly reduced the radiation dose received during the injection therapy of the lumbar facet joints. With minimal effort for the setup at the beginning of a session, the system is easy to handle and can be helpful for other injection therapies (e.g. nerve root block therapies). PMID:19082641
Description and modelling of the solar-hydrogen-biogas-fuel cell system in GlashusEtt
NASA Astrophysics Data System (ADS)
Hedström, L.; Wallmark, C.; Alvfors, P.; Rissanen, M.; Stridh, B.; Ekman, J.
The need to reduce pollutant emissions and utilise the world's available energy resources more efficiently has led to increased attention towards e.g. fuel cells, but also to other alternative energy solutions. In order to further understand and evaluate the prerequisites for sustainable and energy-saving systems, ABB and Fortum have equipped an environmental information centre, located in Hammarby Sjöstad, Stockholm, Sweden, with an alternative energy system. The system is being used to demonstrate and evaluate how a system based on fuel cells and solar cells can function as a complement to existing electricity and heat production. The stationary energy system is situated on the top level of a three-floor glass building and is open to the public. The alternative energy system consists of a fuel cell system, a photovoltaic (PV) cell array, an electrolyser, hydrogen storage tanks, a biogas burner, dc/ac inverters, heat exchangers and an accumulator tank. The fuel cell system includes a reformer and a polymer electrolyte fuel cell (PEFC) with a maximum rated electrical output of 4 kW el and a maximum thermal output of 6.5 kW th. The fuel cell stack can be operated with reformed biogas, or directly using hydrogen produced by the electrolyser. The cell stack in the electrolyser consists of proton exchange membrane (PEM) cells. To evaluate different automatic control strategies for the system, a simplified dynamic model has been developed in MATLAB Simulink. The model based on measurement data taken from the actual system. The evaluation is based on demand curves, investment costs, electricity prices and irradiation. Evaluation criteria included in the model are electrical and total efficiencies as well as economic parameters.
NASA Astrophysics Data System (ADS)
Wang, Juan; Wang, Yue; Yang, Haizhen; Lu, Zhibo; Xu, Xiaotian
2010-11-01
The River Bailianjing is an iconic landscape feature known to all residents in Pudong area and running through the Shanghai Expo 2010 Park. The river and its basin was a complex living ecosystem which supports a unique variety of flora and fauna several decades ago. However, as a result of unsuccessful pollution source control, sewage and first flow of the storm water is directly coming into the river in some catchment. The water quality of the river is seriously organically polluted now. The typical organic pollutants are COD, NH3-N, TN and TP, which cause the extinction of the water plants and aquatic. Furthermore, the artificial hard river banks isolate the river course and the land, which damaged the whole ecological system totally. The nature of the River Bailianjing and its history has resulted in many government departments and authorities and non government organizations having jurisdiction and/or an interest in the river's management. As a new tool to improve river management, the river health assessment has become the major focus of ecological and environmental science. Consequently, research on river health evaluation and its development on river management are of great theoretical and practical significance. In order to evaluate the healthy status of the River Bailianjing and prepare comprehensive scientific background data for the integrated river ecological rehabilitation planning, the health evaluation indicator system for River Bailianjing is brought forward. The indicator system has three levels: the first is target layer; the second is criteria layer, including five fields: water quality characteristics, hydrology characteristics, river morphology, biological characteristics and river scenic beauty; the third is an index layer, a total of 15 specific indicators included. Fuzzy AHP method is used to evaluate the target river's health status, and five grades are set up to describe it: healthy, sub health, marginal, unhealthy and pathological. The methodology and experience of the urban river health evaluation illustrated in the paper can be good case study materials for other cities with the similar situation.
AgIIS, Agricultural Irrigation Imaging System, design and application
NASA Astrophysics Data System (ADS)
Haberland, Julio Andres
Remote sensing is a tool that is increasingly used in agriculture for crop management purposes. A ground-based remote sensing data acquisition system was designed, constructed, and implemented to collect high spatial and temporal resolution data in irrigated agriculture. The system was composed of a rail that mounts on a linear move irrigation machine, and a small cart that runs back and forth on the rail. The cart was equipped with a sensors package that measured reflectance in four discrete wavelengths (550 nm, 660 nm, 720 nm, and 810 nm, all 10 nm bandwidth) and an infrared thermometer. A global positioning system and triggers on the rail indicated cart position. The data was postprocessed in order to generate vegetation maps, N and water status maps and other indices relevant for site-specific crop management. A geographic information system (GIS) was used to generate images of the field on any desired day. The system was named AgIIS (A&barbelow;gricultural I&barbelow;rrigation I&barbelow;maging S&barbelow;ystem). This ground based remote sensing acquisition system was developed at the Agricultural and Biosystems Engineering Department at the University of Arizona in conjunction with the U.S. Water Conservation Laboratory in Phoenix, as part of a cooperative study primarily funded by the Idaho National Environmental and Engineering Laboratory. A second phase of the study utilized data acquired with AgIIS during the 1999 cotton growing season to model petiole nitrate (PNO3 -) and total leaf N. A latin square experimental design with optimal and low water and optimal and low N was used to evaluate N status under water and no water stress conditions. Multivariable models were generated with neural networks (NN) and multilinear regression (MLR). Single variable models were generated from chlorophyll meter readings (SPAD) and from the Canopy Chlorophyll Content Index (CCCI). All models were evaluated against observed PNO3- and total leaf N levels. The NN models showed the highest correlation with PNO3- and total leaf N. AgIIS was a reliable and efficient data acquisition system for research and also showed potential for use in commercial farming systems.
NASA Technical Reports Server (NTRS)
Johnson, Marcus; Jung, Jaewoo; Rios, Joseph; Mercer, Joey; Homola, Jeffrey; Prevot, Thomas; Mulfinger, Daniel; Kopardekar, Parimal
2017-01-01
This study evaluates a traffic management concept designed to enable simultaneous operations of multiple small unmanned aircraft systems (UAS) in the national airspace system (NAS). A five-day flight-test activity is described that examined the feasibility of operating multiple UAS beyond visual line of sight (BVLOS) of their respective operators in the same airspace. Over the five-day campaign, three groups of five flight crews operated a total of eleven different aircraft. Each group participated in four flight scenarios involving five simultaneous missions. Each vehicle was operated BVLOS up to 1.5 miles from the pilot in command. Findings and recommendations are presented to support the feasibility and safety of routine BVLOS operations for small UAS.
NASA Technical Reports Server (NTRS)
Johnson, Marcus; Jung, Jaewoo; Rios, Joseph; Mercer, Joey; Homola, Jeffrey; Prevot, Thomas; Mulfinger, Daniel; Kopardekar, Parimal
2017-01-01
This study evaluates a traffic management concept designed to enable simultaneous operations of multiple small unmanned aircraft systems (UAS) in the national airspace system (NAS). A five-day flight-test activity is described that examined the feasibility of operating multiple UAS beyond visual line of sight (BVLOS) of their respective operators in the same airspace. Over the five-day campaign, three groups of five flight crews operated a total of eleven different aircraft. Each group participated in four flight scenarios involving five simultaneous missions. Each vehicle was operated BVLOS up to 1.5 miles from the pilot in command. Findings and recommendations are presented to support the feasibility and safety of routine BVLOS operations for small UAS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chatterton, Mike
The Recovery Act: Districtwide Geothermal Heating Conversion project performed by the Blaine County School District was part of a larger effort by the District to reduce operating costs, address deferred maintenance items, and to improve the learning environment of the students. This project evaluated three options for the ground source which were Open-Loop Extraction/Re-injection wells, Closed-Loop Vertical Boreholes, and Closed-Loop Horizontal Slinky approaches. In the end the Closed-Loop Horizontal Slinky approach had the lowest total cost of ownership but the majority of the sites associated with this project did not have enough available ground area to install the system somore » the second lowest option was used (Open-Loop). In addition to the ground source, this project looked at ways to retrofit existing HVAC systems with new high efficiency systems. The end result was the installation of distributed waterto- air heat pumps with water-to-water heat pumps installed to act as boilers/chillers for areas with a high ventilation demand such as they gymnasiums. A number of options were evaluated and the lowest total cost of ownership approach was implemented in the majority of the facilities. The facilities where the lowest total cost of ownership approaches was not selected were done to maintain consistency of the systems from facility to facility. This project had a number of other benefits to the Blaine County public. The project utilizes guaranteed energy savings to justify the levy funds expended. The project also developed an educational dashboard that can be used in the classrooms and to educate the community on the project and its performance. In addition, the majority of the installation work was performed by contractors local to Blaine County which acted as an economic stimulus to the area during a period of recession.« less
Waziri, Ndadilnasiya Endie; Nguku, Patrick; Olayinka, Adebola; Ajayi, Ike; Kabir, Junaidu; Okolocha, Emmanuel; Tseggai, Tesfai; Joannis, Tony; Okewole, Phillip; Kumbish, Peterside; Ahmed, Mohammed; Lombin, Lami; Nsubuga, Peter
2014-01-01
Highly pathogenic avian influenza H5N1 was first reported in poultry in Nigeria in February 2006. The only human case that occurred was linked to contact with poultry in a live bird market (LBM). LBM surveillance was instituted to assess the degree of threat of human exposure to H5N1. The key indicator was detection of H5N1 in LBMs. We evaluated the surveillance system to assess its operations and attributes. We used the US Centers for Disease Control and Prevention (CDC) updated guidelines for evaluating public health surveillance systems. We reviewed and analyzed passive surveillance data for HPAI (January 2006-March 2009) from the Avian Influenza National Reference Laboratory, and live bird market surveillance data from the Food and Agriculture Organization of the United Nations, Nigeria. We interviewed key stakeholders and reviewed reports of live bird market surveillance to obtain additional information on the operations of the system. We assessed the key system attributes. A total of 299 cases occurred in 25 (72%) states and the Federal Capital Territory (FCT). The system detected HPAI H5N1 virus in 7 (9.5%) LBMs; 2 (29%) of which were from 2 (18.2%) states with no previous case. A total of 17,852 (91.5%) of samples arrived at the laboratory within 24 hours but laboratory analysis took over 7 days. The sensitivity and positive predictive value (PPV) were 15.4% and 66.7% respectively. The system is useful, flexible, complex and not timely, but appears to be meeting its objectives. The isolation of HPAI H5N1 virus in some of these markets is an indication that the markets are possible reservoirs of the virus in Nigeria. We recommend that the Federal Government of Nigeria should dedicate more funds for surveillance for HPAI as this will aid early warning and reduce the risk of a pandemic.
D'Andrea, G; Capalbo, G; Volpe, M; Marchetti, M; Vicentini, F; Capelli, G; Cambieri, A; Cicchetti, A; Ricciardi, G; Catananti, C
2006-01-01
Our main purpose was to evaluate the organizational appropriateness of admissions made in a university hospital, by comparing two iso-gravity classification systems, APR-DRG and Disease Staging, with the Italian version of AEP (PRUO). Our analysis focused on admissions made in 2001, related to specific Diagnosis Related Groups (DRGs), which, according an Italian Law, would be considered at high risk of inappropriateness, if treated as ordinary admissions. The results obtained by using the 2 classification systems did not show statistically significant differences with respect to the total number of admissions. On the other hand, some DRGs showed statistically significant differences due to different algorithms of attribution of the severity levels used by the two systems. For almost all of the DRGs studied, the AEP-based analysis of a sample of medical records showed an higher number of inappropriate admissions in comparison with the number expected by iso-gravity classification methods. The difference is possibly due to the percentage limits of tolerability fixed by the Law for each DRG. Therefore, the authors suggest an integrated use of the two methods to evaluate organizational appropriateness of hospital admissions.
1993-04-01
separation capability. o Demonstrate advanced KKVs in the 6-20 KG weight class. o Test planning for SRAM/LEAP and PATRIOT/LEAP integrated technology...packaging techniques to reduce satellite size, weight , power, and total system costs. Further development of these technologies are absolutely 4...1993 o Developed a master plan with a delivery schedule for each light- weight subassembly in the sensor integration payload. o Finalized a contract for
Williams, James A; Eddleman, Laura; Pantone, Amy; Martinez, Regina; Young, Stephen; Van Der Pol, Barbara
2014-08-01
Next-generation diagnostics for Chlamydia trachomatis and Neisseria gonorrhoeae are available on semi- or fully-automated platforms. These systems require less hands-on time than older platforms and are user friendly. Four automated systems, the ABBOTT m2000 system, Becton Dickinson Viper System with XTR Technology, Gen-Probe Tigris DTS system, and Roche cobas 4800 system, were evaluated for total run time, hands-on time, and walk-away time. All of the systems evaluated in this time-motion study were able to complete a diagnostic test run within an 8-h work shift, instrument setup and operation were straightforward and uncomplicated, and walk-away time ranged from approximately 90 to 270 min in a head-to-head comparison of each system. All of the automated systems provide technical staff with increased time to perform other tasks during the run, offer easy expansion of the diagnostic test menu, and have the ability to increase specimen throughput. © 2013 Society for Laboratory Automation and Screening.
An effective write policy for software coherence schemes
NASA Technical Reports Server (NTRS)
Chen, Yung-Chin; Veidenbaum, Alexander V.
1992-01-01
The authors study the write behavior and evaluate the performance of various write strategies and buffering techniques for a MIN-based multiprocessor system using the simple software coherence scheme. Hit ratios, memory latencies, total execution time, and total write traffic are used as the performance indices. The write-through write-allocate no-fetch cache using a write-back write buffer is shown to have a better performance than both write-through and write-back caches. This type of write buffer is effective in reducing the volume as well as bursts of write traffic. On average, the use of a write-back cache reduces by 60 percent the total write traffic generated by a write-through cache.
Rintala, Eeva-Maria; Ekholm, Päivi; Koivisto, Pertti; Peltonen, Kimmo; Venäläinen, Eija-Riitta
2014-05-01
We evaluated total and inorganic arsenic levels in long grain rice and rice based baby foods on Finnish market. Inorganic arsenic was analysed with an HPLC-ICP-MS system. The total arsenic concentration was determined with an ICP-MS method. In this study, the inorganic arsenic levels in long grain rice varied from 0.09 to 0.28mg/kg (n=8) and the total arsenic levels from 0.11 to 0.65mg/kg. There was a good correlation between the total and inorganic arsenic levels in long grain rice at a confidence level of 95%. The total arsenic levels of rice-based baby foods were in the range 0.02 - 0.29mg/kg (n=10), however, the level of inorganic arsenic could only be quantitated in four samples, on average they were 0.11mg/kg. Our estimation of inorganic arsenic intake from long grain rice and rice-based baby food in Finland indicate that in every age group the intake is close to the lowest BMDL0.1 value 0.3μg/kg bw/day set by EFSA. According to our data, the intake of inorganic arsenic should be more extensively evaluated. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.
New digital capacitive measurement system for blade clearances
NASA Astrophysics Data System (ADS)
Moenich, Marcel; Bailleul, Gilles
This paper presents a totally new concept for tip blade clearance evaluation in turbine engines. This system is able to detect exact 'measurands' even under high temperature and severe conditions like ionization. The system is based on a heavy duty probe head, a miniaturized thick-film hybrid electronic circuit and a signal processing unit for real time computing. The high frequency individual measurement values are digitally filtered and linearized in real time. The electronic is built in hybrid technology and therefore can be kept extremely small and robust, so that the system can be used on actual flights.
A framework for the direct evaluation of large deviations in non-Markovian processes
NASA Astrophysics Data System (ADS)
Cavallaro, Massimo; Harris, Rosemary J.
2016-11-01
We propose a general framework to simulate stochastic trajectories with arbitrarily long memory dependence and efficiently evaluate large deviation functions associated to time-extensive observables. This extends the ‘cloning’ procedure of Giardiná et al (2006 Phys. Rev. Lett. 96 120603) to non-Markovian systems. We demonstrate the validity of this method by testing non-Markovian variants of an ion-channel model and the totally asymmetric exclusion process, recovering results obtainable by other means.
Computer vision system: a tool for evaluating the quality of wheat in a grain tank
NASA Astrophysics Data System (ADS)
Minkin, Uryi Igorevish; Panchenko, Aleksei Vladimirovich; Shkanaev, Aleksandr Yurievich; Konovalenko, Ivan Andreevich; Putintsev, Dmitry Nikolaevich; Sadekov, Rinat Nailevish
2018-04-01
The paper describes a technology that allows for automatizing the process of evaluating the grain quality in a grain tank of a combine harvester. Special recognition algorithm analyzes photographic images taken by the camera, and that provides automatic estimates of the total mass fraction of broken grains and the presence of non-grains. The paper also presents the operating details of the tank prototype as well as it defines the accuracy of the algorithms designed.
1989-12-01
program manager was evaluated managers in group one will group two, the "less or no sports at all" by at least one additional rater ). In ad- have... determined that for the 34 evaluating the differences between subhypothesis is based on its respective managers, the total number of years group means, each...things like education, experience, age, sex , personality, in- formed within the context of Air Force program managers dividual values, and a specific
Alipour, Vali; Dindarloo, Kavoos; Mahvi, Amir Hossein; Rezaei, Leila
2015-03-01
Corrosion and scaling is a major problem in water distribution systems, thus evaluation of water corrosivity properties is a routine test in water networks. To evaluate water stability in the Bandar Abbas water distribution system, the network was divided into 15 clusters and 45 samples were taken. Langelier, Ryznar, Puckorius, Larson-Skold (LS) and Aggressive indices were determined and compared to the marble test. The mean parameters included were pH (7.8 ± 0.1), electrical conductivity (1,083.9 ± 108.7 μS/cm), total dissolved solids (595.7 ± 54.7 mg/L), Cl (203.5 ± 18.7 mg/L), SO₄(174.7 ± 16.0 mg/L), alkalinity (134.5 ± 9.7 mg/L), total hardness (156.5 ± 9.3 mg/L), HCO₃(137.4 ± 13.0 mg/L) and calcium hardness (71.8 ± 4.3 mg/L). According to the Ryznar, Puckorius and Aggressive Indices, all samples were stable; based on the Langelier Index, 73% of samples were slightly corrosive and the rest were scale forming; according to the LS index, all samples were corrosive. Marble test results showed tested water of all 15 clusters tended to scale formation. Water in Bandar Abbas is slightly scale forming. The most appropriate indices for the network conditions are the Aggressive, Puckorius and Ryznar indices that were consistent with the marble test.
Roukis, Thomas S
2012-01-01
Revision of failed total ankle replacement remains a challenge with limited information available to guide treatment options. I undertook a systematic review of electronic databases and other relevant sources to identify material relating to the incidence of revision after primary implantation of the Agility™ Total Ankle Replacement System. In an effort to procure the highest quality studies available, studies were eligible for inclusion only if they involved patients undergoing primary Agility™ Total Ankle Replacement; had evaluated patients at a mean follow-up of 12 months or longer; included details of the revision performed; and included revision etiologies of aseptic loosening, ballooning osteolysis, cystic changes, malalignment, or instability. A total of 14 studies involving 2312 ankles, with a weighted mean follow-up of 22.8 months, were included. Of the 2312 ankles, 224 (9.7%) underwent revision, of which 182 (81.3%) underwent implant component replacement, 34 (15.2%) underwent arthrodesis, and 8 (3.6%) underwent below-knee amputation. No significant effect from the surgeon's learning curve on the incidence of revision or the type of revision surgery performed was identified. However, excluding the inventor increased the incidence of revision twofold, from 6.6% to 12.2%, and skewed the type of revision away from arthrodesis and toward implant component replacement or below-knee amputation. Regardless, the incidence of revision after primary implantation of the Agility™ Total Ankle Replacement System was less than historically reported and amenable to implant component revision more than 80% of the time. However, methodologically sound cohort studies are needed that include the outcomes after revision surgery, specifically focusing on what implant component replacement techniques are effective in enhancing survivorship of these revised implants and the role of custom-stemmed talar and tibial components have in revision of the Agility™ Total Ankle Replacement System. A direct comparison of the incidence of revision between the various contemporary total ankle replacement systems in common use is also warranted. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Boudousq, V.; Bordy, T.; Gonon, G.; Dinten, J. M.
2005-04-01
The LEXXOS (DMS, Montpellier, France) is the first axial and total body cone beam bone densitometer using a 2D digital radiographic detector. Technical principles and performances for BMD measurements have been presented in previous papers. Bone densitometers are also used on small animals for drug development. In this paper, we show how the LEXXOS system can be adapted to small animals examinations, and its performances are evaluated. At first, in order to take advantage of the whole area of the digital flat panel X-ray detector, the geometrical configuration has been adapted. Secondly, as small animals present low BMD, a specific dual energy calibration has been defined. This adapted system has then been evaluated on two sets of mice: six reference mice and six ovariectomized mice. Each month, these two populations have been examined and the total body BMD has been measured. This evaluation has shown that the right order of BMD magnitude has been obtained and, as expected, BMD increases on the two sets until age of puberty and after this period, decreases significantly for the ovariectomized set. Moreover, the bone image obtained by dual energy processing on LEXXOS presents a radiographic image quality providing with useful complementary information on bone morphometry and architecture.
Use of an appendicitis medical information sheet in the pediatric primary care system.
Oyachi, Noboru; Yagasaki, Hideaki; Suzuki, Takeyuki; Higashida, Kosuke; Komai, Takayuki; Hasuda, Norio; Takano, Kunio; Obana, Kazuko
2016-10-01
Accurate and prompt diagnosis is required for the primary evaluation of pediatric appendicitis. Among pediatricians and surgeons working in Yamanashi Prefecture, the pediatric appendicitis medical information (PAMI) sheet was edited in April 2011 to reflect the diagnostic results of the pediatric primary and emergency medical service and used as a referral document for surgical consultation to secondary hospitals. The PAMI sheet consisted of sections for history taking, symptoms, physical signs and laboratory findings without a scoring system. For 32 consecutive months starting in April 2011, 59 patients hospitalized for suspected appendicitis were retrospectively reviewed. In particular, a total of 17 referral patients evaluated with the PAMI sheet were assessed in order to evaluate the utility of the form. The pediatric surgeons were able to easily determine patient condition from the PAMI sheet. In total, 13 of 17 patients had appendicitis. According to the physical findings of the 17 studied patients, the judgment of right lower quadrant tenderness (κ = 0.63) and guarding (κ = 1.00) was consistent between the pediatric surgeons and primary attending pediatricians. The PAMI sheet aids in the collection of detailed history and objective data with a high level of accuracy, and provides useful referral diagnostic information to the secondary-level hospitals. © 2016 Japan Pediatric Society.
Floré, Katelijne M J; Fiers, Tom; Delanghe, Joris R
2008-01-01
In recent years a number of point of care testing (POCT) glucometers were introduced on the market. We investigated the analytical variability (lot-to-lot variation, calibration error, inter-instrument and inter-operator variability) of glucose POCT systems in a university hospital environment and compared these results with the analytical needs required for tight glucose monitoring. The reference hexokinase method was compared to different POCT systems based on glucose oxidase (blood gas instruments) or glucose dehydrogenase (handheld glucometers). Based upon daily internal quality control data, total errors were calculated for the various glucose methods and the analytical variability of the glucometers was estimated. The total error of the glucometers exceeded by far the desirable analytical specifications (based on a biological variability model). Lot-to-lot variation, inter-instrument variation and inter-operator variability contributed approximately equally to total variance. As in a hospital environment, distribution of hematocrit values is broad, converting blood glucose into plasma values using a fixed factor further increases variance. The percentage of outliers exceeded the ISO 15197 criteria in a broad glucose concentration range. Total analytical variation of handheld glucometers is larger than expected. Clinicians should be aware that the variability of glucose measurements obtained by blood gas instruments is lower than results obtained with handheld glucometers on capillary blood.
Platelet collection efficiencies of three different platelet-rich plasma preparation systems.
Aydin, Fatma; Pancar Yuksel, Esra; Albayrak, Davut
2015-06-01
Different systems have been used for the preparation of platelet-rich plasma (PRP), but platelet collection efficiencies of these systems are not clear. To evaluate the platelet collection efficiencies of three different PRP preparation systems. Blood samples were obtained from the same 16 volunteers for each system. The samples were centrifuged and PRP was prepared by three systems. The ratio of the total number of platelets in PRP to the total number of platelets of the venous blood sample of the patient expressed in percentage was named as platelet collection efficiency and calculated for each system. Mean platelet collection efficiencies were 66.6 (min: 56.9, max: 76.9), 58.3 (min: 27.3, max: 102.8), 50.8 (min: 27.2, max: 73) for top and bottom bag system, system using citrated tube, and the system using tube with Ficoll and cell extraction kit, respectively. Statistically significant difference was found only between the platelet collection efficiencies of systems using the tube with ficoll and cell extraction kit and the top and bottom bag system (p = 0.002). All three systems could be used for PRP preparation, but top and bottom bag system offers a slight advantage over the system using Ficoll and cell extraction kit regarding the platelet collection efficiency.
[ROLE OF THE SYMPATHOADRENOMEDULLARY SYSTEM IN FORMATION OF PILOT'S ADAPTATION TO FLIGHT LOADS].
Sukhoterin, A F; Pashchenko, P S; Plakhov, N N; Zhuravlev, A G
2015-01-01
Purpose of the work was to evaluate the sympathoadrenomedullary functions and associated psychophysiological reactions of pilots as a function of flight hours on highly maneuverable aircraft. Volunteers to the investigation were 78 pilots (41 pilots of maneuverable aircraft and 37 pilots of bombers and transporters). Selected methods were to enable comprehensive evaluation of the body functioning against flight loads. Our results evidence that piloting of high maneuverable aircraft but not of bombing and transporting aircrafts activates the sympathoadrenomedullary system significantly. This is particularly common to young pilots with the total flying time less than 1000 hours. Adaptive changes to flight factors were noted to develop with age and experience.
Le Nguyen, Doan Duy; Ducamp, Marie-Noelle; Dornier, Manuel; Montet, Didier; Reynes, Max; Loiseau, Gérard
2005-08-01
The lactoperoxidase system (LPS) was evaluated for the prevention of postharvest diseases caused by Xanthomonas campestris, Botryodiplodia theobromae, and Colletotrichum gloeosporioides in 'Keitt' and 'Kent' mangoes. The LPS treatment significantly reduced the disease development on both cultivars after storage at 12 degrees C for 2 weeks, which was followed by a ripening at 25 degrees C. The LPS treatment did not alter the sensory quality of mango fruits (color, firmness, titrable acidity, and total soluble solids) when compared to untreated fruits. The LPS thus presents good potential alternative to the chemical fungicides traditionally used to improve the shelf life of mangoes.
2015-12-01
Physical Configuration Audit for the GMLRS AW was completed at the system level in March 2015. Director of Operational Test and Evaluation Assessment...Confidence Level Confidence Level of cost estimate for current APB: 50% The confidence level used in establishing the cost estimate for GMLRS/GMLRS AW...PAUC Development Estimate Changes PAUC Production Estimate Econ Qty Sch Eng Est Oth Spt Total 0.039 -0.003 0.001 0.001 0.009 0.037 0.000 0.000 0.045
Portfolio analysis of layered security measures.
Chatterjee, Samrat; Hora, Stephen C; Rosoff, Heather
2015-03-01
Layered defenses are necessary for protecting the public from terrorist attacks. Designing a system of such defensive measures requires consideration of the interaction of these countermeasures. In this article, we present an analysis of a layered security system within the lower Manhattan area. It shows how portfolios of security measures can be evaluated through portfolio decision analysis. Consideration is given to the total benefits and costs of the system. Portfolio diagrams are created that help communicate alternatives among stakeholders who have differing views on the tradeoffs between security and economic activity. © 2014 Society for Risk Analysis.
The development of a solar residential heating and cooling system
NASA Technical Reports Server (NTRS)
1975-01-01
The MSFC solar heating and cooling facility was assembled to demonstrate the engineering feasibility of utilizing solar energy for heating and cooling buildings, to provide an engineering evaluation of the total system and the key subsystems, and to investigate areas of possible improvement in design and efficiency. The basic solar heating and cooling system utilizes a flat plate solar energy collector, a large water tank for thermal energy storage, heat exchangers for space heating, and an absorption cycle air conditioner for space cooling. A complete description of all systems is given. Development activities for this test system included assembly, checkout, operation, modification, and data analysis, all of which are discussed. Selected data analyses for the first 15 weeks of testing are included, findings associated with energy storage and the energy storage system are outlined, and conclusions resulting from test findings are provided. An evaluation of the data for summer operation indicates that the current system is capable of supplying an average of 50 percent of the thermal energy required to drive the air conditioner. Preliminary evaluation of data collected for operation in the heating mode during the winter indicates that nearly 100 percent of the thermal energy required for heating can be supplied by the system.
The Future Impact of Wind on BPA Power System Ancillary Services
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makarov, Yuri V.; Lu, Shuai; McManus, Bart
Wind power is growing in a very fast pace as an alternative generating resource. As the ratio of wind power over total system capacity increases, the impact of wind on various system aspects becomes significant. This paper presents a methodology to study the future impact of wind on BPA power system ancillary services including load following and regulation. Existing approaches for similar analysis include dispatch model simulation and standard deviation evaluation. The methodology proposed in this paper uses historical data and stochastic processes to simulate the load balancing processes in BPA power system. Then capacity, ramp rate and ramp durationmore » characteristics are extracted from the simulation results, and load following and regulation requirements are calculated accordingly. It mimics the actual power system operations therefore the results can be more realistic yet the approach is convenient to perform. Further, the ramp rate and ramp duration data obtained from the analysis can be used to evaluate generator response or maneuverability and energy requirement, respectively, additional to the capacity requirement.« less
Traffic Congestion Detection System through Connected Vehicles and Big Data
Cárdenas-Benítez, Néstor; Aquino-Santos, Raúl; Magaña-Espinoza, Pedro; Aguilar-Velazco, José; Edwards-Block, Arthur; Medina Cass, Aldo
2016-01-01
This article discusses the simulation and evaluation of a traffic congestion detection system which combines inter-vehicular communications, fixed roadside infrastructure and infrastructure-to-infrastructure connectivity and big data. The system discussed in this article permits drivers to identify traffic congestion and change their routes accordingly, thus reducing the total emissions of CO2 and decreasing travel time. This system monitors, processes and stores large amounts of data, which can detect traffic congestion in a precise way by means of a series of algorithms that reduces localized vehicular emission by rerouting vehicles. To simulate and evaluate the proposed system, a big data cluster was developed based on Cassandra, which was used in tandem with the OMNeT++ discreet event network simulator, coupled with the SUMO (Simulation of Urban MObility) traffic simulator and the Veins vehicular network framework. The results validate the efficiency of the traffic detection system and its positive impact in detecting, reporting and rerouting traffic when traffic events occur. PMID:27136548
Traffic Congestion Detection System through Connected Vehicles and Big Data.
Cárdenas-Benítez, Néstor; Aquino-Santos, Raúl; Magaña-Espinoza, Pedro; Aguilar-Velazco, José; Edwards-Block, Arthur; Medina Cass, Aldo
2016-04-28
This article discusses the simulation and evaluation of a traffic congestion detection system which combines inter-vehicular communications, fixed roadside infrastructure and infrastructure-to-infrastructure connectivity and big data. The system discussed in this article permits drivers to identify traffic congestion and change their routes accordingly, thus reducing the total emissions of CO₂ and decreasing travel time. This system monitors, processes and stores large amounts of data, which can detect traffic congestion in a precise way by means of a series of algorithms that reduces localized vehicular emission by rerouting vehicles. To simulate and evaluate the proposed system, a big data cluster was developed based on Cassandra, which was used in tandem with the OMNeT++ discreet event network simulator, coupled with the SUMO (Simulation of Urban MObility) traffic simulator and the Veins vehicular network framework. The results validate the efficiency of the traffic detection system and its positive impact in detecting, reporting and rerouting traffic when traffic events occur.
NASA Astrophysics Data System (ADS)
Wee, Jung-Ho
Two types of fuel cell systems using NaBH 4 aqueous solution as a fuel are possible: the hydrogen/air proton exchange membrane fuel cell (PEMFC) which uses onsite H 2 generated via the NaBH 4 hydrolysis reaction (B-PEMFC) at the anode and the direct borohydride fuel cell (DBFC) system which directly uses NaBH 4 aqueous solution at the anode and air at the cathode. Recently, research on these two types of fuel cells has begun to attract interest due to the various benefits of this liquid fuel for fuel cell systems for portable applications. It might therefore be relevant at this stage to evaluate the relative competitiveness of the two fuel cells. Considering their current technologies and the high price of NaBH 4, this paper evaluated and analyzed the factors influencing the relative favorability of each type of fuel cell. Their relative competitiveness was strongly dependent on the extent of the NaBH 4 crossover. When considering the crossover in DBFC systems, the total costs of the B-PEMFC system were the most competitive among the fuel cell systems. On the other hand, if the crossover problem were to be completely overcome, the total cost of the DBFC system generating six electrons (6e-DBFC) would be very similar to that of the B-PEMFC system. The DBFC system generating eight electrons (8e-DBFC) became even more competitive if the problem of crossover can be overcome. However, in this case, the volume of NaBH 4 aqueous solution consumed by the DBFC was larger than that consumed by the B-PEMFC.
2014-01-01
Background The purpose of the study was twofold: first, to determine whether there is a statistically significant difference in the metal ion levels among three different large-head metal-on-metal (MOM) total hip systems. The second objective was to assess whether position of the implanted prostheses, patient demographics or factors such as activity levels influence overall blood metal ion levels and whether there is a difference in the functional outcomes between the systems. Methods In a cross-sectional cohort study, three different metal-on-metal total hip systems were assessed: two monoblock heads, the Durom socket (Zimmer, Warsaw, IN, USA) and the Birmingham socket (Smith and Nephew, Memphis, TN, USA), and one modular metal-on-metal total hip system (Pinnacle, Depuy Orthopedics, Warsaw, IN, USA). Fifty-four patients were recruited, with a mean age of 59.7 years and a mean follow-up time of 41 months (12 to 60). Patients were evaluated clinically, radiologically and biochemically. Statistical analysis was performed on all collected data to assess any differences between the three groups in terms of overall blood metal ion levels and also to identify whether there was any other factor within the group demographics and outcomes that could influence the mean levels of Co and Cr. Results Although the functional outcome scores were similar in all three groups, the blood metal ion levels in the larger monoblock large heads (Durom, Birmingham sockets) were significantly raised compared with those of the Pinnacle group. In addition, the metal ion levels were not found to have a statistically significant relationship to the anteversion or abduction angles as measured on the radiographs. Conclusions When considering a MOM THR, the use of a monoblock large-head system leads to higher elevations in whole blood metal ions and offers no advantage over a smaller head modular system. PMID:24472283
Biological treatment process for removing petroleum hydrocarbons from oil field produced waters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tellez, G.; Khandan, N.
1995-12-31
The feasibility of removing petroleum hydrocarbons from oil fields produced waters using biological treatment was evaluated under laboratory and field conditions. Based on previous laboratory studies, a field-scale prototype system was designed and operated over a period of four months. Two different sources of produced waters were tested in this field study under various continuous flow rates ranging from 375 1/D to 1,800 1/D. One source of produced water was an open storage pit; the other, a closed storage tank. The TDS concentrations of these sources exceeded 50,000 mg/l; total n-alkanes exceeded 100 mg/l; total petroleum hydrocarbons exceeded 125 mg/l;more » and total BTEX exceeded 3 mg/l. Removals of total n-alkanes, total petroleum hydrocarbons, and BTEX remained consistently high over 99%. During these tests, the energy costs averaged $0.20/bbl at 12 bbl/D.« less
Kumakiri, Jun; Kikuchi, Iwaho; Kitade, Mari; Matsuoka, Shozo; Kono, Ayako; Takeda, Satoru
2012-04-01
To evaluate the benefit of the intraoperative use of a cell salvage and autologous blood recovery system during laparoscopic myomectomy (LM). We retrospectively reviewed the medical records of 538 patients who underwent LM between January 2008 and December 2009 at our hospital. Patients undergoing LM were divided into two groups depending on whether the cell salvage and autologous blood recovery system was used; the use of the system was at the discretion of the surgeon. The system for intraoperative hemorrhage was employed based on the surgeon's decision. Of the 583 patients, 23 patients (4.3%) underwent LM using the system. No patient required an allogeneic blood transfusion during or after the surgery. The median surgical time (183 vs. 100 m), total blood loss (520 vs. 100 mL), total weight of enucleated myomas (390 vs. 175 g), and postoperative calculated δ-Hemoglobin (δ-Hb) (2 vs. 1.6 g/dL) were significantly increased in the 23 patients in whom the system was used. The median autologous blood volume recovered by intraoperative use of the system and transferred to the 23 patients was 250 mL (range 125-800 mL). For patients in whom the system was not used, the total blood loss significantly correlated to δ-Hb (r = 0.29; P < 0.01). However, there was no such correlation in patients in whom the system was not used (r = 0.04; P = 0.86). The adoption of a cell salvage and autologous blood recovery system during LM was useful for patients with severe hemorrhage.
Emergy Evaluation of a Production and Utilization Process of Irrigation Water in China
Chen, Dan; Luo, Zhao-Hui; Chen, Jing; Kong, Jun; She, Dong-Li
2013-01-01
Sustainability evaluation of the process of water abstraction, distribution, and use for irrigation can contribute to the policy of decision making in irrigation development. Emergy theory and method are used to evaluate a pumping irrigation district in China. A corresponding framework for its emergy evaluation is proposed. Its emergy evaluation shows that water is the major component of inputs into the irrigation water production and utilization systems (24.7% and 47.9% of the total inputs, resp.) and that the transformities of irrigation water and rice as the systems' products (1.72E + 05 sej/J and 1.42E + 05 sej/J, resp.; sej/J = solar emjoules per joule) represent their different emergy efficiencies. The irrigated agriculture production subsystem has a higher sustainability than the irrigation water production subsystem and the integrated production system, according to several emergy indices: renewability ratio (%R), emergy yield ratio (EYR), emergy investment ratio (EIR), environmental load ratio (ELR), and environmental sustainability index (ESI). The results show that the performance of this irrigation district could be further improved by increasing the utilization efficiencies of the main inputs in both the production and utilization process of irrigation water. PMID:24082852
Emergy evaluation of a production and utilization process of irrigation water in China.
Chen, Dan; Luo, Zhao-Hui; Chen, Jing; Kong, Jun; She, Dong-Li
2013-01-01
Sustainability evaluation of the process of water abstraction, distribution, and use for irrigation can contribute to the policy of decision making in irrigation development. Emergy theory and method are used to evaluate a pumping irrigation district in China. A corresponding framework for its emergy evaluation is proposed. Its emergy evaluation shows that water is the major component of inputs into the irrigation water production and utilization systems (24.7% and 47.9% of the total inputs, resp.) and that the transformities of irrigation water and rice as the systems' products (1.72E + 05 sej/J and 1.42E + 05 sej/J, resp.; sej/J = solar emjoules per joule) represent their different emergy efficiencies. The irrigated agriculture production subsystem has a higher sustainability than the irrigation water production subsystem and the integrated production system, according to several emergy indices: renewability ratio (%R), emergy yield ratio (EYR), emergy investment ratio (EIR), environmental load ratio (ELR), and environmental sustainability index (ESI). The results show that the performance of this irrigation district could be further improved by increasing the utilization efficiencies of the main inputs in both the production and utilization process of irrigation water.
Reliability and Generalizability of Ratings of Compositions.
ERIC Educational Resources Information Center
Lehmann, Rainer H.
A total of 1,487 eleventh grade students from the Hamburg (West Germany) school system were asked to complete four writing assignments used in an International Association for the Evaluation of Educational Achievement (IEA) study of writing assessment. In analyzing the writing samples, the study focused on: (1) between-rater effects; (2)…
Studying Tonal Complexity, with a Special Reference to Mande Languages
ERIC Educational Resources Information Center
Konoshenko, Maria
2014-01-01
Linguists tend to believe that total complexity of human languages is invariable. In order to test this hypothesis empirically, we need to calculate the complexity in different domains of language structure: phonology, morphology, syntax, etc. In this paper I provide some guidelines for documenting tonal systems and evaluating their complexity. I…
International Trade. U.S. Metric Study Interim Report.
ERIC Educational Resources Information Center
Gordon, Gerald F.
In order to evaluate the potential effects of U.S. conversion to SI (Systems International) units on U.S. foreign trade, 188 export product classes and 155 import product classes were selected from 1,166 Standard Industrial Classification (SIC) product classes and questionnaires were mailed to a total of 510 firms, utilizing separate forms for…
Survey of Different Types of Communication in Swimming Education
ERIC Educational Resources Information Center
Biro, Melinda
2007-01-01
Study aim: To evaluate verbal and non-verbal behaviour of teachers and pupils in elementary swimming education and their impact on pupils' achievements. Material and methods: A total of 77 swimming lessons were videorecorded and coded with the modified Cheffers' Adaptation of Flanders Interaction Analysis System (CAFIAS); 46 PE teachers, swimming…
Fuel Cell Auxiliary Power Study Volume 1: RASER Task Order 5
NASA Technical Reports Server (NTRS)
Mak, Audie; Meier, John
2007-01-01
This study evaluated the feasibility of a hybrid solid oxide fuel cell (SOFC) auxiliary power unit (APU) and the impact in a 90-passenger More-Electric Regional Jet application. The study established realistic hybrid SOFC APU system weight and system efficiencies, and evaluated the impact on the aircraft total weight, fuel burn, and emissions from the main engine and the APU during cruise, landing and take-off (LTO) cycle, and at the gate. Although the SOFC APU may be heavier than the current conventional APU, its weight disadvantage can be offset by fuel savings in the higher SOFC APU system efficiencies against the main engine bleed and extraction during cruise. The higher SOFC APU system efficiency compared to the conventional APU on the ground can also provide considerable fuel saving and emissions reduction, particularly at the gate, but is limited by the fuel cell stack thermal fatigue characteristic.
Evaluation of three composting systems for the management of spent coffee grounds.
Liu, K; Price, G W
2011-09-01
This study was conducted to evaluate the optimum composting approach for the management of spent coffee grounds from the restaurant and ready-to-serve coffee industry. Three composting systems were assessed, including in-vessel composting, vermicomposting bins, and aerated static pile bin composting, over study periods ranging from 47 to 98 days. Total carbon content was reduced by 5-7% in the spent coffee ground treatments across the three composting systems. Nitrogen and other mineral nutrient contents were conserved or enhanced from the initial to the final composts in all the composting systems assessed. Earthworm growth and survival (15-80%) was reduced in all the treatments but mortality rates were lower in coffee treatments with cardboard additions. A decline in earthworm mortality with cardboard additions was the result of reduced exposure to organic compounds and chemicals released through the decomposition of spent coffee grounds. Copyright © 2011 Elsevier Ltd. All rights reserved.
Applicability of Zeolite Based Systems for Ammonia Removal and Recovery From Wastewater.
Das, Pallabi; Prasad, Bably; Singh, Krishna Kant Kumar
2017-09-01
Ammonia discharged in industrial effluents bears deleterious effects and necessitates remediation. Integrated systems devoted to recovery of ammonia in a useful form and remediation of the same addresses the challenges of waste management and its utilization. A comparative performance evaluation study was undertaken to access the suitability of different zeolite based systems (commercial zeolites and zeolites synthesized from fly ash) for removal of ammonia followed by its subsequent release. Four main parameters which were studied to evaluate the applicability of such systems for large scale usage are cost-effectiveness, ammonia removal efficiency, performance on regeneration, and ammonia release percentage. The results indicated that synthetic zeolites outperformed zeolites synthesized from fly ash, although the later proved to be more efficient in terms of total cost incurred. Process technology development in this direction will be a trade-of between cost and ammonia removal and release efficiencies.
Access Control for Mobile Assessment Systems Using ID.
Nakayama, Masaharu; Ishii, Tadashi; Morino, Kazuma
2015-01-01
The assessment of shelters during disaster is critical to ensure the health of evacuees and prevent pandemic. In the Ishinomaki area, one of the areas most damaged by the Great East Japan Earthquake, the highly organized assessment helped to successfully manage a total of 328 shelters with a total of 46,480 evacuees. The input and analysis of vast amounts of data was tedious work for staff members. However, a web-based assessment system that utilized mobile devices was thought to decrease workload and standardize the evaluation form. The necessary access of information should be controlled in order to maintain individuals' privacy. We successfully developed an access control system using IDs. By utilizing a unique numerical ID, users can access the input form or assessment table. This avoids unnecessary queries to the server, resulting in a quick response and easy availability, even with poor internet connection.
Evaluation of a proposed method for representing drug terminology.
Cimino, J. J.; McNamara, T. J.; Meredith, T.; Broverman, C. A.; Eckert, K. C.; Moore, M.; Tyree, D. J.
1999-01-01
In the absence of a single, standard, multipurpose terminology for representing medications, the HL7 Vocabulary Technical Committee has sought to develop a model for such terms in a way that will provide a unified method for representing them and supporting interoperability among various terminology systems. We evaluated the preliminary model by obtaining terms, represented in our model, from three leading vendors of pharmacy system knowledge bases. A total of 2303 terms were obtained, and 3982 pair-wise comparisons were possible. We found that the components of the term descriptions matched 68-87% of the time and that the overall descriptions matched 53% of the time. The evaluation has identified a number of areas in the model where more rigorous definitions will be needed in order to improve the matching rate. This paper discusses the implications of these results. PMID:10566318
Avionics systems integration technology
NASA Technical Reports Server (NTRS)
Stech, George; Williams, James R.
1988-01-01
A very dramatic and continuing explosion in digital electronics technology has been taking place in the last decade. The prudent and timely application of this technology will provide Army aviation the capability to prevail against a numerically superior enemy threat. The Army and NASA have exploited this technology explosion in the development and application of avionics systems integration technology for new and future aviation systems. A few selected Army avionics integration technology base efforts are discussed. Also discussed is the Avionics Integration Research Laboratory (AIRLAB) that NASA has established at Langley for research into the integration and validation of avionics systems, and evaluation of advanced technology in a total systems context.
Alkali metal/halide thermal energy storage systems performance evaluation
NASA Technical Reports Server (NTRS)
Phillips, W. M.; Stearns, J. W.
1986-01-01
A pseudoheat-pipe heat transfer mechanism has been demonstrated effective in terms of both total heat removal efficiency and rate, on the one hand, and system isothermal characteristics, on the other, for solar thermal energy storage systems of the kind being contemplated for spacecraft. The selection of appropriate salt and alkali metal substances for the system renders it applicable to a wide temperature range. The rapid heat transfer rate obtainable makes possible the placing of the thermal energy storage system around the solar receiver canister, and the immersing of heat transfer fluid tubes in the phase change salt to obtain an isothermal heat source.
Evaluation of a Quartz Bourdon Pressure Gage of Wind Tunnel Mach Number Control System Application
NASA Technical Reports Server (NTRS)
Chapin, W. G.
1986-01-01
A theoretical and experimental study was undertaken to determine the feasibility of using the National Transonic Facility's high accuracy Mach number measurement system as part of a closed loop Mach number control system. The theoretical and experimental procedures described are applicable to the engineering design of pressure control systems. The results show that the dynamic response characteristics of the NTF Mach number gage (a Ruska DDR-6000 quartz absolute pressure gage) coupled to a typical length of pressure tubing were only marginally acceptable within a limited range of the facility's total pressure envelope and could not be used in the Mach number control system.
Mission operations concepts for Earth Observing System (EOS)
NASA Technical Reports Server (NTRS)
Kelly, Angelita C.; Taylor, Thomas D.; Hawkins, Frederick J.
1991-01-01
Mission operation concepts are described which are being used to evaluate and influence space and ground system designs and architectures with the goal of achieving successful, efficient, and cost-effective Earth Observing System (EOS) operations. Emphasis is given to the general characteristics and concepts developed for the EOS Space Measurement System, which uses a new series of polar-orbiting observatories. Data rates are given for various instruments. Some of the operations concepts which require a total system view are also examined, including command operations, data processing, data accountability, data archival, prelaunch testing and readiness, launch, performance monitoring and assessment, contingency operations, flight software maintenance, and security.
Villegas-Guzman, Paola; Silva-Agredo, Javier; González-Gómez, Duván; Giraldo-Aguirre, Ana L; Flórez-Acosta, Oscar; Torres-Palma, Ricardo A
2015-01-01
The photocalytic degradation of dicloxacillin (DXC) using TiO2 was studied in synthetic and natural waters. The degradation route and the effect of different experimental variables such as pH, applied power, and the initial concentrations of DXC and the catalyst were investigated. The best performances were achieved at a natural pH 5.8 and using 2.0 g L(-1) of TiO2 with 150 W of applied power. The photodegradation process followed Langmuir-Hinshelwood kinetics. The water matrix effect was evaluated in terms of degradation efficiency in the presence of organic compounds (oxalic acid, glucose), Fe(2+) ion and natural water. An increase in degradation was observed when ferrous ion was part of the solution, but the process was inhibited with all evaluated organic compounds. Similarly, inhibition was observed when natural water was used instead of distilled water. The extent of degradation of the process was evaluated following the evolution of chemical oxygen demand (COD), antimicrobial activity (AA), total organic carbon (TOC) and biochemical oxygen demand (BOD5). Total removal of DXC was achieved after 120 min of treatment and 95% mineralization was observed after 480 min of treatment. Additionally, the total removal of antimicrobial activity and a high level of biodegradability were observed after the photocalytical system had been operating for 240 min.
NASA Astrophysics Data System (ADS)
Safaei, Mohsen; Anton, Steven R.
2017-04-01
A common application of piezoelectric transducers is to obtain operational data from working structures and dynamic components. Collected data can then be used to evaluate dynamic characterization of the system, perform structural health monitoring, or implement various other assessments. In some applications, piezoelectric transducers are bonded inside the host structure to satisfy system requirements; for example, piezoelectric transducers can be embedded inside the biopolymers of total joint replacements to evaluate the functionality of the artificial joint. The interactions between the piezoelectric device (inhomogeneity) and the surrounding polymer matrix determine the mechanical behavior of the matrix and the electromechanical behavior of the sensor. In this work, an analytical approach is employed to evaluate the electromechanical performance of 2-D plane strain piezoelectric elements of both circular and rectangular-shape inhomogeneities. These piezoelectric elements are embedded inside medical grade ultra-high molecular weight (UHMW) polyethylene, a material commonly used for bearing surfaces of joint replacements, such as total knee replacements (TKRs). Using the famous Eshelby inhomogeneity solution, the stress and electric field inside the circular (elliptical) inhomogeneity is obtained by decoupling the solution into purely elastic and dielectric systems of equations. For rectangular (non-elliptical) inhomogeneities, an approximation method based on the boundary integral function is utilized and the same decoupling method is employed. In order to validate the analytical result, a finite element analysis is performed for both the circular and rectangular inhomogeneities and the error for each case is calculated. For elliptical geometry, the error is less than 1% for stress and electric fields inside and outside the piezoelectric inhomogeneity, whereas, the error for non-elliptical geometry is obtained as 11% and 7% for stress and electric field inside the inhomogeneity, respectively.
A novel estimating method for steering efficiency of the driver with electromyography signals
NASA Astrophysics Data System (ADS)
Liu, Yahui; Ji, Xuewu; Hayama, Ryouhei; Mizuno, Takahiro
2014-05-01
The existing research of steering efficiency mainly focuses on the mechanism efficiency of steering system, aiming at designing and optimizing the mechanism of steering system. In the development of assist steering system especially the evaluation of its comfort, the steering efficiency of driver physiological output usually are not considered, because this physiological output is difficult to measure or to estimate, and the objective evaluation of steering comfort therefore cannot be conducted with movement efficiency perspective. In order to take a further step to the objective evaluation of steering comfort, an estimating method for the steering efficiency of the driver was developed based on the research of the relationship between the steering force and muscle activity. First, the steering forces in the steering wheel plane and the electromyography (EMG) signals of the primary muscles were measured. These primary muscles are the muscles in shoulder and upper arm which mainly produced the steering torque, and their functions in steering maneuver were identified previously. Next, based on the multiple regressions of the steering force and EMG signals, both the effective steering force and the total force capacity of driver in steering maneuver were calculated. Finally, the steering efficiency of driver was estimated by means of the estimated effective force and the total force capacity, which represented the information of driver physiological output of the primary muscles. This research develops a novel estimating method for driver steering efficiency of driver physiological output, including the estimation of both steering force and the force capacity of primary muscles with EMG signals, and will benefit to evaluate the steering comfort with an objective perspective.
Masuda, Syuzo; Oka, Ryusho; Uwai, Koji; Matsuda, Yumi; Shiraishi, Tadashi; Nakagawa, Yoshito; Shoji, Tohru; Mihara, Chie; Takeshita, Mitsuhiro; Ozawa, Koichiro
2009-09-01
One of the important roles of pharmacists as members of a nutrition support team is nutritional prescription support. We developed a nutritional prescription support system (NPSS) that facilitates prescription support and analysis and evaluated its usefulness in nutritional therapy. An NPSS for prescription support and the management of patient information was created. With this NPSS, the nutritional status was assessed, and, on the basis of the results, such variables as the total energy expenditure were calculated. This system allows prescription support for parenteral nutrition (PN) therapy, enteral nutrition (EN) therapy, and the transition period between them. This system was used for 2 representative patients and evaluated. In a malnourished patient receiving oral warfarin, EN solutions were compared by means of the NPSS, and an appropriate EN solution was selected. In addition, the prothrombin time-international normalized ratio was monitored, and favorable results were obtained regarding the adjustment of the warfarin dose and nutritional management. In a patient with aspiration pneumonia, continuous nutritional management to EN from PN therapy was straightforwardly performed with the NPSS. This NPSS allows rapid, comprehensive nutritional management during the transition period to EN from PN therapy, despite these therapies being considered separately in conventional nutritional management. The NPSS is useful for simplifying prescription support and facilitating information sharing among members of a nutrition support team.
Al Ansari, Ahmed; Al Khalifa, Khalid; Al Azzawi, Mohamed; Al Amer, Rashed; Al Sharqi, Dana; Al-Mansoor, Anwar; Munshi, Fadi M
2015-01-01
We aimed to design, implement, and evaluate the feasibility and reliability of a multisource feedback (MSF) system to assess interns in their clerkship year in the Middle Eastern culture, the Kingdom of Bahrain. The study was undertaken in the Bahrain Defense Force Hospital, a military teaching hospital in the Kingdom of Bahrain. A total of 21 interns (who represent the total population of the interns for the given year) were assessed in this study. All of the interns were rotating through our hospital during their year-long clerkship rotation. The study sample consisted of nine males and 12 females. Each participating intern was evaluated by three groups of raters, eight medical intern colleagues, eight senior medical colleagues, and eight coworkers from different departments. A total of 21 interns (nine males and 12 females) were assessed in this study. The total mean response rates were 62.3%. A factor analysis was conducted that found that the data on the questionnaire grouped into three factors that counted for 76.4% of the total variance. These three factors were labeled as professionalism, collaboration, and communication. Reliability analysis indicated that the full instrument scale had high internal consistency (Cronbach's α 0.98). The generalizability coefficients for the surveys were estimated to be 0.78. Based on our results and analysis, we conclude that the MSF tool we used on the interns rotating in their clerkship year within our Middle Eastern culture provides an effective method of evaluation because it offers a reliable, valid, and feasible process.
Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty
NASA Technical Reports Server (NTRS)
Mather, Janice L.; Taylor, Shawn C.
2015-01-01
In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.
Microleakage of 4 post-luting cements evaluated by the computerized fluid filtration method.
Ceyhanli, Kadir T; Orucoglu, Hasan; Erdilek, Necdet; Turkun, Murat; Akdağ, Mustafa S
2015-12-01
The aim of this study was to evaluate the microleakage of 4 fiber post-luting systems using the computerized fluid filtration method. 60 extracted human mandibular permanent premolar teeth were used for the study. The teeth were instrumented with Hedstroem files up to size 60, post spaces were prepared and then Unicore fiber posts were cemented using 4 luting systems. Group1: Duolink, Group 2: Resinomer, Group 3: Fuji Plus, Group 4: Multilink Sprint, Group 5: Positive Control, and Group 6: Negative Control. The samples were stored in distilled water for 2 weeks and then microleakage was evaluated. Data were analyzed with 1 way-ANOVA and Dunett T3 tests (P<.05). Groups 2 and 3 significantly exhibited higher microleakage values than groups 1 and 4 (P<.05). Resin cements used with total etch-bonding systems demonstrated lower microleakage values than the other cements. Reduction of steps in dentin conditioning of resin luting cements may have a promoting effect on microleakage.
Tungsten wire-reinforced superalloys for 1093 C (2000 F) turbine blade applications
NASA Technical Reports Server (NTRS)
Friedman, G. I.; Fleck, J. N.
1979-01-01
Various combinations of fiber and matrix materials were fabricated and evaluated for the purpose of selecting a specific combination that exhibited the best overall properties for a turbine blade application. A total of seven matrix alloys, including Hastelloy X, Nimonic 80A, Inconel 600, Inconel 625, IN-102, FeCrA1Y, were investigated reinforced with either 218CS tungsten, or W-Hf-C fibers. Based on preliminary screening studies, FeCrA1Y, Inconel 600 and Inconel 625 matrix composites systems were selected for extended thermal cycle tests and for property evaluations which included stress rupture, impact, and oxidation resistance. Of those investigated, the FeCrA1Y matrix composite system exhibited the best overall properties required for a turbine blade application. The W-Hf-C/FeCrA1Y system was selected for further property evaluation. Tensile strength values of up to 724 MPa (105,000 psi) were obtained for this material at 982 C and 607 MPa at 1093 C.
Wake Vortex Advisory System (WakeVAS) Evaluation of Impacts on the National Airspace System
NASA Technical Reports Server (NTRS)
Smith, Jeremy C.; Dollyhigh, Samuel M.
2005-01-01
This report is one of a series that describes an ongoing effort in high-fidelity modeling/simulation, evaluation and analysis of the benefits and performance metrics of the Wake Vortex Advisory System (WakeVAS) Concept of Operations being developed as part of the Virtual Airspace Modeling and Simulation (VAMS) project. A previous study, determined the overall increases in runway arrival rates that could be achieved at 12 selected airports due to WakeVAS reduced aircraft spacing under Instrument Meteorological Conditions. This study builds on the previous work to evaluate the NAS wide impacts of equipping various numbers of airports with WakeVAS. A queuing network model of the National Airspace System, built by the Logistics Management Institute, Mclean, VA, for NASA (LMINET) was used to estimate the reduction in delay that could be achieved by using WakeVAS under non-visual meteorological conditions for the projected air traffic demand in 2010. The results from LMINET were used to estimate the total annual delay reduction that could be achieved and from this, an estimate of the air carrier variable operating cost saving was made.
Traffic Light System Can Increase Healthfulness Perception: Implications for Policy Making.
Machín, Leandro; Aschemann-Witzel, Jessica; Curutchet, María Rosa; Giménez, Ana; Ares, Gastón
2018-04-04
To evaluate how information about low nutrient content included in the traffic light labeling system influences consumers' perception of the healthfulness of products with high content of 1 key nutrient, and to compare the traffic light system with warnings in terms of the perception of healthfulness. Images of front-of-pack (FOP) nutrition labels (the traffic light labeling system with different numbers of nutrients with low content, and warnings) were evaluated in study 1, whereas product labels featuring the different FOP nutrition labels were evaluated in study 2. Online studies conducted in Montevideo, Uruguay. A total of 1,228 Uruguayan Facebook users. Perception of healthfulness. The researchers used ANOVA to evaluate the influence of FOP nutrition labels on perceived healthfulness. The inclusion of information about low nutrient content in the traffic light system statistically significantly increased the perception of the healthfulness of products with high nutrient content. Nutritional warnings showed healthfulness ratings similar to those of the simplified version of the traffic light system. Information about low nutrient content in the traffic light system might be used to infer health, and thus could raise the perception of healthfulness and decrease the traffic light system's efficacy in discouraging the consumption of unhealthful products. A simplified version of the traffic light highlighting only high-nutrient content or nutritional warnings seems to overcome this problem. Copyright © 2018 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
A self-made, low-cost infrared system for evaluating the sciatic functional index in mice.
Fricker, Lukas; Penna, Vincenzo; Lampert, Florian; Stark, G Bjoern; Witzel, Christian; Koulaxouzidis, Georgios
2016-05-01
The sciatic functional index (SFI) is a popular parameter for peripheral nerve evaluation that relies on footprints obtained with ink and paper. Drawbacks include smearing artefacts and a lack of dynamic information during measurement. Modern applications use digitized systems that can deliver results with less analytical effort and fewer mice. However, the systems are expensive (€40,000). This study aimed to evaluate the applicability and precision of a self-made, low-cost infrared system for evaluating SFI in mice. Mice were subjected to unilateral sciatic nerve crush injury (crush group; n = 7) and sham operation (sham group; n = 4). They were evaluated on the day before surgery, the 2(nd), 4(th) and 6(th) days after injury, and then every day up to the 23(rd) day after injury. We compared two SFI evaluation methods, i.e., conventional ink-and-paper SFI (C-SFI) and our infrared system (I-SFI). Our apparatus visualized footprints with totally internally reflected infrared light (950 nm) and a camera that can only detect this wavelength. Additionally we performed an analysis with the ladder beam walking test (LBWT) as a reference test. I-SFI assessment reduced the standard deviation by about 33 percent, from 11.6 to 7.8, and cut the variance around the baseline to 21 percent. The system thus requires fewer measurement repetitions and fewer animals, and cuts the cost of keeping the animals. The apparatus cost €321 to build. Our results show that the process of obtaining the SFI can be made more precise via digitization with a self-made, low-cost infrared system.
A self-made, low-cost infrared system for evaluating the sciatic functional index in mice
Fricker, Lukas; Penna, Vincenzo; Lampert, Florian; Stark, G. Bjoern; Witzel, Christian; Koulaxouzidis, Georgios
2016-01-01
The sciatic functional index (SFI) is a popular parameter for peripheral nerve evaluation that relies on footprints obtained with ink and paper. Drawbacks include smearing artefacts and a lack of dynamic information during measurement. Modern applications use digitized systems that can deliver results with less analytical effort and fewer mice. However, the systems are expensive (€40,000). This study aimed to evaluate the applicability and precision of a self-made, low-cost infrared system for evaluating SFI in mice. Mice were subjected to unilateral sciatic nerve crush injury (crush group; n = 7) and sham operation (sham group; n = 4). They were evaluated on the day before surgery, the 2nd, 4th and 6th days after injury, and then every day up to the 23rd day after injury. We compared two SFI evaluation methods, i.e., conventional ink-and-paper SFI (C-SFI) and our infrared system (I-SFI). Our apparatus visualized footprints with totally internally reflected infrared light (950 nm) and a camera that can only detect this wavelength. Additionally we performed an analysis with the ladder beam walking test (LBWT) as a reference test. I-SFI assessment reduced the standard deviation by about 33 percent, from 11.6 to 7.8, and cut the variance around the baseline to 21 percent. The system thus requires fewer measurement repetitions and fewer animals, and cuts the cost of keeping the animals. The apparatus cost €321 to build. Our results show that the process of obtaining the SFI can be made more precise via digitization with a self-made, low-cost infrared system. PMID:27335570
A wearable sensor system for medication adherence prediction.
Kalantarian, Haik; Motamed, Babak; Alshurafa, Nabil; Sarrafzadeh, Majid
2016-05-01
Studies have revealed that non-adherence to prescribed medication can lead to hospital readmissions, clinical complications, and other negative patient outcomes. Though many techniques have been proposed to improve patient adherence rates, they suffer from low accuracy. Our objective is to develop and test a novel system for assessment of medication adherence. Recently, several smart pill bottle technologies have been proposed, which can detect when the bottle has been opened, and even when a pill has been retrieved. However, very few systems can determine if the pill is subsequently ingested or discarded. We propose a system for detecting user adherence to medication using a smart necklace, capable of determining if the medication has been ingested based on the skin movement in the lower part of the neck during a swallow. This, coupled with existing medication adherence systems that detect when medicine is removed from the bottle, can detect a broader range of use-cases with respect to medication adherence. Using Bayesian networks, we were able to correctly classify between chewable vitamins, saliva swallows, medication capsules, speaking, and drinking water, with average precision and recall of 90.17% and 88.9%, respectively. A total of 135 instances were classified from a total of 20 subjects. Our experimental evaluations confirm the accuracy of the piezoelectric necklace for detecting medicine swallows and disambiguating them from related actions. Further studies in real-world conditions are necessary to evaluate the efficacy of the proposed scheme. Copyright © 2016 Elsevier B.V. All rights reserved.
Xu, Jianling; Yang, Jiaqi; Zhao, Nan; Sheng, Lianxi; Zhao, Yuanhui; Tang, Zhanhui
2011-12-01
The physical, chemical, and biological indices of aircraft liquid wastes collected from multiple airplanes at Longjia Airport, Changchun, China were measured according to "Integrated Wastewater Discharge Standard," evaluating treatment efficiency of resolvable sanitizing liquid. The results indicate that, after being treated by the resolvable sanitizing liquid, the indices of all first-class pollutants met the requirements of the standard, while among the second-class pollutants, the suspension content, biochemical oxygen demand after 5 days, and chemical oxygen demand as well as the contents of amino nitrogen, total phosphorus, anionic surfactants, total copper, absorbable organic halogen, and phenolic compounds did not reach the discharge standard. Particularly, the level of fecal coliform bacteria in the aircraft liquid wastes can meet the standard specification by adding more than 1 mL/L resolvable sanitizing liquid. The aircraft wastewater treated by resolvable sanitizing liquid cannot be directly discharged back into the environment as well as urban drainage systems.
Point-of-Care Test Equipment for Flexible Laboratory Automation.
You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol
2014-08-01
Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.
NASA Astrophysics Data System (ADS)
Hayashi, I.; Kaneko, S.
2014-02-01
Pressure pulsations excited by a centrifugal turbomachinery such as compressor, fan or pump at the blade passing frequency may cause severe noise and vibrations in piping system. Therefore, the practical evaluation method of pressure pulsations is strongly recommended. In particular, the maximum pressure amplitude under the resonant conditions should be appropriately evaluated. In this study, a one-dimensional excitation source model for a compressor or pump is introduced based on the equation of motion, so as to incorporate the non-linear damping proportional to velocity squared in the total piping system including the compressor or pump. The damping characteristics of the compressor or pump are investigated by using the semi-empirical model. It is shown that the resistance coefficient of the compressor or pump depends on the Reynolds number that is defined using the equivalent velocity of the pulsating flow. The frequency response of the pressure amplitude and the pressure distribution in the piping system can be evaluated by introducing the equivalent resistance of the compressor or pump and that of piping system. In particular, the relation of the maximum pressure amplitude in piping system to the location of the excitation source under resonant conditions can be evaluated. Finally, the reduction of the pressure pulsations by use of an orifice plate is discussed in terms of the pulsation energy loss.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wen, N., E-mail: nwen1@hfhs.org; Snyder, K. C.; Qin, Y.
2016-05-15
Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2more » mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.« less