A comparison of serum and plasma cytokine values using a multiplexed assay in cats.
Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Paradise, Hayley; Vaden, Shelly; Lascelles, B D X
2016-12-01
Degenerative joint disease (DJD) is highly prevalent in cats, and pain contributes to morbidity. In humans, alterations of cytokine concentrations have been associated with joint deterioration and pain. Similar changes have not been investigated in cats. Cytokine concentrations can be measured using multiplex technology with small samples of serum or plasma, however, serum and plasma are not interchangeable for most bioassays. Correlations for cytokine concentrations between serum and plasma have not been evaluated in cats. To evaluate the levels of detection and agreement between serum and plasma samples in cats. Paired serum and plasma samples obtained from 38 cats. Blood was collected into anti-coagulant free and EDTA Vacutainer ® tubes, serum or plasma extracted, and samples frozen at -80°C until testing. Duplicate samples were tested using a 19-plex feline cytokine/chemokine magnetic bead panel. Agreement between serum and plasma for many analytes was high, however correlation coefficients ranged from -0.01 to 0.97. Results from >50% of samples were below the lower limit of quantification for both serum and plasma for nine analytes, and for an additional three analytes for plasma only. While serum and plasma agreement was generally good, detection was improved using serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluation of pharmacokinetics and the stability of daptomycin in serum at various temperatures.
Ogami, Chika; Tsuji, Yasuhiro; Kasai, Hidefumi; Hiraki, Yoichi; Yamamoto, Yoshihiro; Matsunaga, Kazuhisa; Karube, Yoshiharu; To, Hideto
2017-04-01
Daptomycin exhibits concentration-dependent antibacterial activity. By monitoring daptomycin serum concentrations, clinicians may be able to predict the effectiveness of treatments for infections more accurately. However, it has been reported that daptomycin concentrations in plasma samples stored at -20°C decrease approximately 25% after 4 weeks. The aim of this study was to evaluate the stability of daptomycin in serum at various temperatures. Daptomycin serum samples were prepared and stored at different temperatures. The stability of daptomycin under various conditions was evaluated by sequential measurements of concentration. Although the loss of concentration of daptomycin in serum samples stored in freezers (-80°C and -20°C) was less than 10% after 168days (6 months), the concentrations in samples stored in a refrigerator (4°C) decreased by more than 70% over the same period. Furthermore, daptomycin concentrations in serum samples stored at close to body temperature (35°C, 37°C, and 39°C) decreased by more than 50% after only 24h. The results of the present study demonstrate that the measurement of serum concentrations of daptomycin needs to be performed rapidly. Furthermore, the degradation of daptomycin in serum may be involved in its elimination from the living body. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A
2006-06-01
To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.
Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc
2018-04-06
Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saunders, G.C.
1977-01-01
A rapid enzyme-labeled antibody (ELA) microtechnique for the screening of swine for hog cholera antibodies was developed and evaluated with a blind study, using a 640-sample hog cholera serum bank. The total time to run a group of 22 samples was approximately 1 hour. The ELA test results correlated >99% with hog cholera serum-neutralization test results on the same serums. Test results also indicated that the ELA test shares with the hog cholera serum-neutralization test the problem of cross reactions between the antibodies of hog cholera and bovine viral diarrhea.
NASA Astrophysics Data System (ADS)
Hernández-Caraballo, Edwin A.; Burguera, Marcela; Burguera, José L.
2002-12-01
A method for the determination of total selenium in serum samples by graphite furnace atomic absorption spectrometry was evaluated. The method involved direct introduction of 1:5 diluted serum samples (1% v/v NH 4OH+0.05% w/v Triton X-100 ®) into transversely heated graphite tubes, and the use of 10 μg Pd+3 μg Mg(NO 3) 2 as chemical modifier. Optimization of the modifier mass and the atomization temperature was conducted by simultaneously varying such parameters and evaluating both the integrated absorbance and the peak height/peak area ratio. The latter allowed the selection of compromise conditions rendering good sensitivity and adequate analyte peak profiles. A characteristic mass of 49 pg and a detection limit (3s) of 6 μg 1 -1 Se, corresponding to 30 μg l -1 Se in the serum sample, were obtained. The analyte addition technique was used for calibration. The accuracy was assessed by the determination of total selenium in Seronorm™ Trace Elements Serum Batch 116 (Nycomed Pharma AS). The method was applied for the determination of total selenium in ten serum samples taken from individuals with no known physical affection. The selenium concentration ranged between 79 and 147 μg l -1, with a mean value of 114±22 μg l -1.
Evaluation of an enzyme immunoassay for detection of dengue virus NS1 antigen in human serum.
Dussart, Philippe; Labeau, Bhety; Lagathu, Gisèle; Louis, Philippe; Nunes, Marcio R T; Rodrigues, Sueli G; Storck-Herrmann, Cécile; Cesaire, Raymond; Morvan, Jacques; Flamand, Marie; Baril, Laurence
2006-11-01
We evaluated a one-step sandwich-format microplate enzyme immunoassay for detecting dengue virus NS1 antigen (Ag) in human serum by use of Platelia Dengue NS1 Ag kits (Bio-Rad Laboratories, Marnes La Coquette, France). We collected 299 serum samples from patients with dengue disease and 50 serum samples from patients not infected with dengue virus. For the 239 serum samples from patients with acute infections testing positive by reverse transcription-PCR and/or virus isolation for one of the four dengue virus serotypes, the sensitivity of the Platelia Dengue NS1 Ag kit was 88.7% (95% confidence interval, 84.0% to 92.4%). None of the serum samples from patients not infected with dengue virus tested positive with the Platelia Dengue NS1 Ag kit. A diagnostic strategy combining the Platelia Dengue NS1 Ag test for acute-phase sera and immunoglobulin M capture enzyme-linked immunosorbent assay for early-convalescent-phase sera increased sensitivity only from 88.7% to 91.9%. Thus, NS1 antigen detection with the Platelia Dengue NS1 Ag kit could be used for first-line testing for acute dengue virus infection in clinical diagnostic laboratories.
Effect of storage duration on cytokine stability in human serum and plasma.
Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James
2018-06-14
Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.
Duque, Andrés; Martínez, Paula-Juliana; Giraldo, Astrid; Gualtero, Diego F.; Ardila, Carlos-Martín; Contreras, Adolfo; Duarte, Silvia
2017-01-01
Background The validity of the surveys on self-reported smoking status is often questioned because smokers underestimate cigarette use and deny the habit. It has been suggested that self-report should be accompanied by cotinine test. This report evaluates the usefulness of serum cotinine test to assess the association between smoking and periodontal status in a study with a large sample population to be used in studies with other serum markers in epidemiologic and periodontal medicine researches. Material and Methods 578 patients who were part of a multicenter study on blood biomarkers were evaluated about smoking and its relation to periodontal disease. Severity of periodontal disease was determinate using clinical attachment loss (CAL). Smoking was assessed by a questionnaire and a blood sample drawn for serum cotinine determination. Results The optimal cut-off point for serum cotinine was 10 ng/ml. Serum cotinine showed greater association with severity of CAL than self-report for mild-moderate CAL [OR 2.03 (CI95% 1.16-3.53) vs. OR 1.08 (CI95% 0.62-1.87) ] advanced periodontitis [OR 2.36 (CI95% 1.30- 4.31) vs. OR 2.06 (CI95% 0.97-4.38) ] and extension of CAL > 3 mm [ OR 1.78 (CI95% 1.16-1.71) vs. 1.37 (CI95% 0.89-2.11)]. When the two tests were evaluated together were not shown to be better than serum cotinine test. Conclusions Self-reported smoking and serum cotinine test ≥ 10ng/ml are accurate, complementary and more reliable methods to assess the patient’s smoking status and could be used in studies evaluating serum samples in large population and multicenter studies. Clinical Relevance: The serum cotinine level is more reliable to make associations with the patient’s periodontal status than self-report questionnaire and could be used in multicenter and periodontal medicine studies. Key words:Biological markers, serum, cotinine, periodontitis, smoking. PMID:28578367
[Clinical evaluation of a novel HBsAg quantitative assay].
Takagi, Kazumi; Tanaka, Yasuhito; Naganuma, Hatsue; Hiramatsu, Kumiko; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi
2007-07-01
The clinical implication of the hepatitis B surface antigen (HBsAg) concentrations in HBV-infected individuals remains unclear. The aim of this study was to evaluate a novel fully automated Chemiluminescence Enzyme Immunoassay (Sysmex HBsAg quantitative assay) by comparative measurements of the reference serum samples versus two independent commercial assays (Lumipulse f or Architect HBsAg QT). Furthermore, clinical usefulness was assessed for monitoring of the serum HBsAg levels during antiviral therapy. A dilution test using 5 reference-serum samples showed linear correlation curve in range from 0.03 to 2,360 IU/ml. The HBsAg was measured in total of 400 serum samples and 99.8% had consistent results between Sysmex and Lumipulse f. Additionally, a positive linear correlation was observed between Sysmex and Architect. To compare the Architect and Sysmex, both methods were applied to quantify the HBsAg in serum samples with different HBV genotypes/subgenotypes, as well as in serum contained HBV vaccine escape mutants (126S, 145R). Correlation between the methods was observed in results for escape mutants and common genotypes (A, B, C) in Japan. Observed during lamivudine therapy, an increase in HBsAg and HBV DNA concentrations preceded the aminotransferase (ALT) elevation associated with drug-resistant HBV variant emergence (breakthrough hepatitis). In conclusion, reliability of the Sysmex HBsAg quantitative assay was confirmed for all HBV genetic variants common in Japan. Monitoring of serum HBsAg concentrations in addition to HBV DNA quantification, is helpful in evaluation of the response to lamivudine treatment and diagnosis of the breakthrough hepatitis.
O'Neal, Wanda K; Anderson, Wayne; Basta, Patricia V; Carretta, Elizabeth E; Doerschuk, Claire M; Barr, R Graham; Bleecker, Eugene R; Christenson, Stephanie A; Curtis, Jeffrey L; Han, Meilan K; Hansel, Nadia N; Kanner, Richard E; Kleerup, Eric C; Martinez, Fernando J; Miller, Bruce E; Peters, Stephen P; Rennard, Stephen I; Scholand, Mary Beth; Tal-Singer, Ruth; Woodruff, Prescott G; Couper, David J; Davis, Sonia M
2014-01-08
As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100). 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers.
2014-01-01
Background As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100™). Methods 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. Results 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. Conclusions There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers. PMID:24397870
Vijaylakshmi, P; Muthukkaruppan, V R; Rajasundari, A; Korukluoglu, G; Nigatu, W; L A Warrener; Samuel, D; Brown, D W G
2006-12-01
Clinical diagnosis (surveillance) of rubella is unreliable and laboratory confirmation is essential. Detection of virus specific IgM in serum is the most commonly used method. However, the use of serum necessitates the drawing of blood, either through venipuncture or finger/heel prick, which can be difficult in young babies. Oral fluid samples have proved useful as an alternative, less invasive sample for virus specific IgM detection however until recently no commercial rubella IgM tests were available, restricting the usefulness of this approach. To evaluate the performance of the Microimmune Rubella IgM capture EIA using oral fluid samples from outbreaks as well as in cases of suspected congenital rubella syndrome (CRS). Paired serum and oral fluids were collected from cases during a rubella outbreak in three provinces in Turkey. Matched serum and oral fluid samples were collected from children with suspected CRS in an active surveillance programme at the Aravind Eye Hospital in South India. Serum samples were collected as part of the measles surveillance programme in Ethiopia. On serum samples the sensitivity and specificity of the Microimmune Rubella IgM capture EIA compared to Behring Enzygnost rubella IgM test was 96.9% (62/64; 95% CI 94.2-100%) and 100% (53/53; 95% CI 93.2-100%). On oral fluids compared to matched Behring results on serum the sensitivity was 95.5% (42/44; 95% CI 84.5-99.4%). The sensitivity and specificity of Microimmune Rubella IgM capture EIA on oral fluids from suspected CRS cases compared to serum results using Behring Enzygnost IgM assay was 100% (95% CI 84.5-100%) and 100% (95% CI 95.8-100.0%) respectively. Microimmune Rubella IgM capture EIA has adequate performance for diagnosis and surveillance of rubella in outbreak using either serum or oral fluid specimens.
Duque, A; Martínez, P-J; Giraldo, A; Gualtero, D-F; Ardila, C-M; Contreras, A; Duarte, S; Lafaurie, G-I
2017-07-01
The validity of the surveys on self-reported smoking status is often questioned because smokers underestimate cigarette use and deny the habit. It has been suggested that self-report should be accompanied by cotinine test. This report evaluates the usefulness of serum cotinine test to assess the association between smoking and periodontal status in a study with a large sample population to be used in studies with other serum markers in epidemiologic and periodontal medicine researches. 578 patients who were part of a multicenter study on blood biomarkers were evaluated about smoking and its relation to periodontal disease. Severity of periodontal disease was determinate using clinical attachment loss (CAL). Smoking was assessed by a questionnaire and a blood sample drawn for serum cotinine determination. The optimal cut-off point for serum cotinine was 10 ng/ml. Serum cotinine showed greater association with severity of CAL than self-report for mild-moderate CAL [OR 2.03 (CI95% 1.16-3.53) vs. OR 1.08 (CI95% 0.62-1.87) ] advanced periodontitis [OR 2.36 (CI95% 1.30- 4.31) vs. OR 2.06 (CI95% 0.97-4.38) ] and extension of CAL > 3 mm [ OR 1.78 (CI95% 1.16-1.71) vs. 1.37 (CI95% 0.89-2.11)]. When the two tests were evaluated together were not shown to be better than serum cotinine test. Self-reported smoking and serum cotinine test ≥ 10ng/ml are accurate ,complementary and more reliable methods to assess the patient's smoking status and could be used in studies evaluating serum samples in large population and multicenter studies. The serum cotinine level is more reliable to make associations with the patient's periodontal status than self-report questionnaire and could be used in multicenter and periodontal medicine studies.
An enzyme-linked immunosorbent assay for the evaluation of thrombocytopenia induced by heparin.
Howe, S E; Lynch, D M
1985-05-01
Five patients with heparin-associated thrombocytopenia (HAT) were evaluated by platelet aggregation and quantitation of immunoglobulin binding to intact target platelets in both the presence and absence of heparin. These patients developed thrombocytopenia (12,000 to 70,000 platelets/microliter) 7 to 15 days and embolic and hemorrhagic complications 9 to 15 days after the initiation of heparin therapy. Platelet aggregation after the addition of heparin was demonstrated in two of four HAT serum samples, whereas normal serum samples showed no significant platelet aggregation. The five HAT serum samples showed normal to elevated baseline serum platelet-bindable immunoglobulin (SPBIg) with a range of 4.3 to 11.4 fg/platelet (normal less than or equal to 1.0 to 6.5 fg/platelet). When HAT sera were incubated with target platelets and heparin (5 U/ml), the SPBIg increased to 8.5 to 37.5 fg/platelet, a mean increase of 148% in the presence of heparin. Normal and control serum samples (from 10 normal laboratory volunteers, nine patients without thrombocytopenia receiving heparin, nine patients with autoimmune thrombocytopenic purpura, and nine patients with nonimmune thrombocytopenia not receiving heparin) showed only a slight increase in SPBIg of 0 to 2.8 fg/platelet above baseline, a mean increase of 15% after heparin incubation with the serum samples. The measurement of SPBIg of washed platelets incubated with test serum samples in the presence and absence of heparin is potentially a specific and sensitive in vitro test for the diagnosis of HAT and may prove more sensitive than platelet aggregation studies with heparin.
Sia, I G; Wilson, J A; Espy, M J; Paya, C V; Smith, T F
2000-02-01
Detection of cytomegalovirus (CMV) DNA in blood by PCR is a sensitive method for the detection of infection in patients posttransplantation. The test, however, has low specificity for the identification of overt CMV disease. Quantitative CMV PCR has been shown to overcome this shortcoming. The COBAS AMPLICOR CMV MONITOR test was evaluated by using consecutive serum and peripheral blood mononuclear cell (PBMN) samples from liver transplant patients. Twenty-five patients had CMV viremia (by shell vial cell culture assay) and/or tissue-invasive disease (by biopsy); 20 had no active infection. A total of 262 serum and 62 PBMN specimens were tested. Of 159 serum specimens from patients with overt CMV infection, the COBAS assay detected CMV DNA in 21 patients (sensitivity, 84%). Only 1 of 103 samples from patients with no evidence of active infection had detectable CMV DNA (341 copies/ml). By comparison of 62 matching serum and PBMN samples by the same assay, 12 PBMN samples were exclusively positive, whereas only 2 serum samples were exclusively positive (P < 0.05). At the time of clinical CMV infection, viral copy numbers were higher in PBMNs than serum from four of five patients. The COBAS AMPLICOR CMV MONITOR test is a sensitive and specific test for the quantitative detection of CMV DNA in blood. Clinical applications of the assay will require further validation with samples from a larger population of transplant patients.
Sia, Irene G.; Wilson, Jennie A.; Espy, Mark J.; Paya, Carlos V.; Smith, Thomas F.
2000-01-01
Detection of cytomegalovirus (CMV) DNA in blood by PCR is a sensitive method for the detection of infection in patients posttransplantation. The test, however, has low specificity for the identification of overt CMV disease. Quantitative CMV PCR has been shown to overcome this shortcoming. The COBAS AMPLICOR CMV MONITOR test was evaluated by using consecutive serum and peripheral blood mononuclear cell (PBMN) samples from liver transplant patients. Twenty-five patients had CMV viremia (by shell vial cell culture assay) and/or tissue-invasive disease (by biopsy); 20 had no active infection. A total of 262 serum and 62 PBMN specimens were tested. Of 159 serum specimens from patients with overt CMV infection, the COBAS assay detected CMV DNA in 21 patients (sensitivity, 84%). Only 1 of 103 samples from patients with no evidence of active infection had detectable CMV DNA (341 copies/ml). By comparison of 62 matching serum and PBMN samples by the same assay, 12 PBMN samples were exclusively positive, whereas only 2 serum samples were exclusively positive (P < 0.05). At the time of clinical CMV infection, viral copy numbers were higher in PBMNs than serum from four of five patients. The COBAS AMPLICOR CMV MONITOR test is a sensitive and specific test for the quantitative detection of CMV DNA in blood. Clinical applications of the assay will require further validation with samples from a larger population of transplant patients. PMID:10655353
Walsh, Robert B.; Kelton, David F.; Hietala, Sharon K.; Duffield, Todd F.
2013-01-01
Serum and milk samples from 1229 cows on 22 Ontario dairy farms were individually tested for antibodies specific for bovine leukosis virus (BLV) and Neospora caninum by enzyme-linked immunosorbent assay (ELISA). Antibodies against BLV were present in 361 serum samples (29.4%) and 369 milk samples (30.0%). Comparing the 2 tests, agreement was almost perfect (k = 0.86; 95% CI = 0.83 to 0.90) and the proportions of samples positive were not significantly different (P = 0.56). Both tests identified the same 3 herds free of bovine leukosis virus. Antibodies against N. caninum were detected in 138 serum samples (11.2%), and 111 milk samples (9.0%). Agreement between the 2 tests was moderate (k = 0.52; 95% CI = 0.43 to 0.59). Four herds were free of neosporosis by the serum test, while 10 herds were negative by the milk test. The ELISA on milk samples facilitates sample collection to classify herds free of BLV; the milk N. caninum ELISA was less reliable in predicting herd-level infection. PMID:24082160
Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.
Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen
2016-12-01
Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.
Borchardt, Stefan; Staufenbiel, Rudolf
2012-04-15
To evaluate the use of nonesterified fatty acids (NEFA) and β-hydroxybutyrate (BHBA) concentrations in pooled serum samples for herd-based detection of subclinical ketosis (SCK) in dairy cows after calving. Cross-sectional study. 1,100 dairy cows from 110 herds. Blood samples were collected from 10 healthy cows/herd in the first week after parturition. Aliquots of serum were mixed to create a pooled sample. Concentrations of NEFA and BHBA were measured to estimate prevalence of SCK. Pooled sample test results were compared with those obtained for individual samples. Linear regression and receiver-operating characteristic curve analysis were performed; Bland-Altman plots were used to evaluate agreement between methods. Overall prevalence of SCK was 30.7%, 19.3%, and 13.6%, as determined by use of BHBA threshold concentrations of 1,000, 1,200, and 1,400 μmol/L, respectively. Pooled sample concentrations of NEFA and BHBA were significantly correlated (r = 0.98 and 0.97, respectively) with individual sample means and with the number of cows that had NEFA (R(2) range, 0.81 to 0.84) or BHBA (R(2) range, 0.65 to 0.76) concentrations above predefined thresholds. Pooled sample concentrations of NEFA and BHBA were very accurate to highly accurate for herd-based detection of SCK. Analysis of NEFA and BHBA concentrations in pooled serum samples was useful for herd-based detection of SCK. A sample size of 10 cows/herd was deemed adequate for monitoring dairy herds for SCK. Reference criteria specific to pooled samples should be used for this type of herd-based testing.
Protain, Holly J; Kutzler, Michelle A; Valentine, Beth A
2009-05-01
To determine whether results of cytologic evaluation of preputial epithelial cells correspond to results of a serum endocrine hormone assay and clinical signs associated with adrenocortical disease in castrated ferrets. 13 clinically normal ferrets and 8 ferrets with signs of adrenocortical disease. Blood and preputial lavage samples were collected from each ferret. Serum samples were submitted to the University of Tennessee Veterinary Diagnostic Laboratory for performance of an endocrine hormone assay. Differential epithelial cell counts were performed on preputial lavage samples to determine the percentage of cornified cells. Results of cytologic evaluation were compared with results of the endocrine hormone assay and clinical status of ferrets. The percentage of cornified preputial epithelial cells was not significantly correlated with serum 17B-estradiol or androstenedione concentration but was significantly correlated with serum 17-hydroxyprogesterone concentration (r = 0.60). The percentage of cornified preputial epithelial cells was higher in ferrets with clinical signs of adrenocortical disease (mean +/- SD, 71.3 +/- 16.9%) than in clinically normal ferrets (55.5 +/- 19.0%). Cornification of preputial epithelial cells was correlated with an increase in serum 17-hydroxyprogesterone concentration as well as clinical signs of adrenocortical disease in castrated ferrets. Additional investigation is needed to elucidate the mechanism of preputial epithelial cell cornification in castrated ferrets.
Akiyama, Tomoyuki; Hayashi, Yumiko; Hanaoka, Yoshiyuki; Shibata, Takashi; Akiyama, Mari; Tsuchiya, Hiroki; Yamaguchi, Tokito; Kobayashi, Katsuhiro
2017-09-01
We quantified pyridoxal 5'-phosphate (PLP), pyridoxal (PL), and 4-pyridoxic acid (PA) in paired serum and cerebrospinal fluid (CSF) samples from children and investigated the effect of age on the concentrations and CSF-to-serum ratios of these vitamers. Serum and CSF samples prospectively collected from 49 pediatric patients were analyzed. PLP, PL, and PA were measured using high-performance liquid chromatography with fluorescence detection, using pre-column derivatization by semicarbazide. Effects of age on these vitamers, the PLP-to-PL ratio, CSF-to-serum PLP ratio, and CSF-to-serum PL ratio were evaluated using correlation analysis. The PLP, PL, and PA concentrations in the serum and CSF were higher at younger ages, except for CSF PA concentrations that were mostly below the limit of detection (<1.2nmol/l). The PLP-to-PL ratios in the serum and CSF correlated positively with age. The CSF-to-serum PLP ratio and CSF-to-serum PL ratio were independent of age. Age-related changes in PLP, PL, and PA in serum and in CSF from pediatric patients and CSF-to-serum ratios of PLP and PL demonstrated in this study will provide valuable information for evaluating PLP supply to the central nervous system from the peripheral blood. Copyright © 2017 Elsevier B.V. All rights reserved.
Jemima, Ebenezer Angel; Manoharan, Seeralan; Kumanan, Kathaperumal
2014-08-01
The measurement of neutralizing antibodies induced by the glycoprotein of rabies virus is indispensable for assessing the level of neutralizing antibodies in animals or humans. A rapid fluorescent focus inhibition test (RFFIT) has been approved by WHO and is the most widely used method to measure the virus-neutralizing antibody content in serum, but a rapid test system would be of great value to screen large numbers of serum samples. To develop and evaluate a latex agglutination test (LAT) for measuring rabies virus antibodies, a recombinant glycoprotein was expressed in an insect cell system and purified, and the protein was coated onto latex beads at concentrations of 0.1, 0.25, 0.5, 0.75, and 1 mg/ml to find out the optimal concentration for coating latex beads. It was found that 0.5 mg/ml of recombinant protein was optimal for coating latex beads, and this concentration was used to sensitize the latex beads for screening of dog serum samples. Grading of LAT results was done with standard reference serum with known antibody titers. A total of 228 serum samples were tested, out of which 145 samples were positive by both RFFIT and LAT, and the specificity was found to be 100 %. In RFFIT, 151 samples were positive, the sensitivity was found to be 96.03 %, and the accuracy/concordance was found to be 97.39 %. A rapid field test-a latex agglutination test (LAT)-was developed and evaluated for rabies virus antibody assessment using recombinant glycoprotein of rabies virus expressed in an insect cell system.
Long-term in vitro reactivity for HLA antibodies and comparison of detection using serum vs. plasma
Norris, Philip J.; Lee, Jar-How; Carrick, Danielle M.; Gottschall, Jerome L.; Lebedeva, Mila; de Castro, B.R.; Kleinman, Steven H.; Busch, Michael P.
2010-01-01
BACKGROUND HLA antibodies are a possible cause of transfusion-related acute lung injury (TRALI), and fluorescent bead assays are often used for antibody detection. Serum is the manufacturer’s recommended sample, but plasma may be easier to obtain for studies of HLA antibody prevalence and TRALI case investigations. STUDY DESIGN AND METHODS Specimens were obtained from 44 multiparous females positive for HLA antibodies by lymphocytotoxicity testing at least 13 years prior, and from 1,000 contemporary blood donors. Screening tests were performed using a Luminex-based assay. In addition to comparing results obtained with paired plasma and serum samples, the effects of storage at 4 °C for one week and of multiple freeze-thaw cycles were evaluated. RESULTS Of 42 evaluable subjects with HLA antibodies documented >13 years earlier, only 1 showed loss of detectable antibodies, with 39 (93%) positive in the screening assay for class I and 24 (57%) positive in the screening assay for HLA class II antibodies. In 968 evaluable contemporary donors, 291 screened positive for HLA class I and 206 for HLA class II antibodies using a low assay cut-off. Screening test concordance using paired plasma and serum samples was high, particularly for subjects with higher level antibodies. Refrigeration of samples for one week did not significantly affect assay results, while repeated freeze-thaw cycles caused a decrement in signal level. CONCLUSION Serum and plasma samples gave concordant results in the majority of cases, particularly for specimens with higher-level antibodies. High-level HLA antibodies were present in most individuals for over 13 years. PMID:18980615
Drug residues in serum of dogs receiving anticancer chemotherapy.
Knobloch, A; Mohring, S A I; Eberle, N; Nolte, I; Hamscher, G; Simon, D
2010-01-01
The presence of drug residues in blood samples can represent an occupational hazard. However, studies on cytotoxic drug residues in serum of dogs are lacking in veterinary oncology. To evaluate possible occupational hazards associated with handling of blood samples from dogs receiving oncolytic drugs 7 days after treatment. Twenty-seven client-owned dogs treated for lymphoma or mast cell tumors with vincristine, vinblastine, cyclophosphamide, or doxorubicin. Prospective, observational study. Serum samples were either taken 7 days after administration of vincristine, cyclophosphamide, doxorubicin (lymphoma), and vinblastine (mast cell tumor), or 1-2 days after the last concurrent oral administration of cyclophosphamide (mast cell tumor). Additionally, serum was collected within 5 minutes of treatment. Measurement of drug residues in serum was performed by liquid chromatography tandem mass spectrometry (LC/MS/MS). In 33 samples collected within 5 minute of treatment, the median serum concentrations were vincristine: 37 microg/L (range: 11-87 microg/L), vinblastine: 13 microg/L (range: 13-35 microg/L), cyclophosphamide: 2,484 microg/L (range: 1,209-2,778 microg/L), doxorubicin: 404 microg/L (range: 234-528 microg/L). In 81 serum samples collected 7 days after treatment vinblastine (7 microg/L) was detected in 1 sample, and cyclophosphamide (7 and 9 microg/L) in 2 samples collected 1-2 days after oral administration of cyclophosphamide. Medications were not detected in any of the other samples. Handling of blood samples from dogs receiving oncolytic chemotherapy 7 days after treatment with vincristine, vinblastine, cyclophosphamide, and doxorubicin should not present a health hazard.
Effect of Repeated Freezing and Thawing on 18 Clinical Chemistry Analytes in Rat Serum
Kale, Vijay P; Patel, Sweta G; Gunjal, Prashant S; Wakchaure, Santosh U; Sundar, Rajesh S; Ranvir, Ramchandra K; Jain, Mukul R
2012-01-01
In a preclinical research laboratory, using serum samples that have been frozen and thawed repeatedly is sometimes unavoidable when needing to confirm previous results or perform additional analysis. Here we determined the effects of multiple cycles of refrigeration or freezing and thawing of rat serum at 3 temperature conditions for different storage times on clinical chemistry analytes. Serum samples obtained from adult Wistar rats were stored at 2 to 8 °C and −10 to −20 °C for as long as 72 h and at −70 °C for as long as 30 d. At different time points (24, 48, and 72 h for samples stored at 2 to 8 °C or −10 to −20 °C and 1, 7, and 30 d for samples stored at −70 °C), the samples were brought to room temperature, analyzed, and then stored again at the designated temperature. The results obtained after each storage cycle were compared with those obtained from the initial analysis of fresh samples. Of the 18 serum analytes evaluated, 14 were stable without significant changes, even after 3 freeze–thaw cycles at the tested temperature ranges. Results from this study will help researchers working with rat serum to interpret the biochemical data obtained from serum samples that have been frozen and thawed repeatedly. PMID:23043814
Fukasawa, Lucila Okuyama; Gonçalves, Maria Gisele; Higa, Fábio Takenori; Castilho, Euclides Ayres; Ibarz-Pavón, Ana Belén; Sacchi, Claudio Tavares
2017-01-01
The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo's national surveillance for routine diagnosis were selected for this study. The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF) samples processed using our laboratory's standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer's instructions. The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory's standard methodology, results showed high concordance, with Kappa index ranges of 0.9877-1.00 for CSF, and 0.8004-1.00 for serum samples. The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow obtaining valuable epidemiological information that would otherwise be lost.
USDA-ARS?s Scientific Manuscript database
Serum samples were collected from 582 horses from 40 stud farms in the State of São Paulo and tick (Acari: Ixodidae) infestations were evaluated on them. Serum samples were subjected to the complement fixation test (CFT) and a competitive inhibition ELISA (cELISA) for Babesia caballi and Theileria e...
Hou, Siyuan; Riley, Christopher B; Mitchell, Cynthia A; Shaw, R Anthony; Bryanton, Janet; Bigsby, Kathryn; McClure, J Trenton
2015-09-01
Immunoglobulin G (IgG) is crucial for the protection of the host from invasive pathogens. Due to its importance for human health, tools that enable the monitoring of IgG levels are highly desired. Consequently there is a need for methods to determine the IgG concentration that are simple, rapid, and inexpensive. This work explored the potential of attenuated total reflectance (ATR) infrared spectroscopy as a method to determine IgG concentrations in human serum samples. Venous blood samples were collected from adults and children, and from the umbilical cord of newborns. The serum was harvested and tested using ATR infrared spectroscopy. Partial least squares (PLS) regression provided the basis to develop the new analytical methods. Three PLS calibrations were determined: one for the combined set of the venous and umbilical cord serum samples, the second for only the umbilical cord samples, and the third for only the venous samples. The number of PLS factors was chosen by critical evaluation of Monte Carlo-based cross validation results. The predictive performance for each PLS calibration was evaluated using the Pearson correlation coefficient, scatter plot and Bland-Altman plot, and percent deviations for independent prediction sets. The repeatability was evaluated by standard deviation and relative standard deviation. The results showed that ATR infrared spectroscopy is potentially a simple, quick, and inexpensive method to measure IgG concentrations in human serum samples. The results also showed that it is possible to build a united calibration curve for the umbilical cord and the venous samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Kiska, D L; Orkiszewski, D R; Howell, D; Gilligan, P H
1994-01-01
We evaluated the performance of CRYPTO-LEX (Trinity Laboratories, Inc., Raleigh, N. C.), a new mouse immunoglobulin M monoclonal antibody latex agglutination reagent which reacts with the capsular polysaccharide of the four serogroups of Cryptococcus neoformans. This test was compared with CALAS (Meridian Diagnostics, Cincinnati, Ohio) for the ability to detect cryptococcal antigen in serum and cerebrospinal fluid (CSF). A total of 580 clinical specimens (327 serum and 253 CSF samples), primarily from human immunodeficiency virus-infected patients, were tested in this study. Sixty-seven specimens (44 serum and 23 CSF samples) were positive for cryptococcal antigen with both tests, and 511 (282 serum and 229 CSF samples) were negative. The two latex reagents agreed for 326 of 327 serum specimens (44 positives and 282 negatives). One serum specimen with a titer of 1:2 was CALAS positive but CRYPTO-LEX negative. The titer correlation coefficient for the two tests was 0.884 when two highly discordant serum specimens were eliminated from analysis of the data. The two latex tests agreed for 252 of 253 CSF specimens (23 positives and 229 negatives). One specimen with a titer of 1:2 was positive with CALAS and negative by CRYPTO-LEX. The correlation coefficient of the two tests for CSF titers was 0.886. The sensitivity and specificity of CRYPTO-LEX were 97 and 100%, respectively, with a 99.6% correlation with CALAS. These data show that the performance of CRYPTO-LEX is comparable to that of CALAS for detection of cryptococcal antigen in serum and CSF. PMID:7814566
Küme, Tuncay; Sağlam, Barıs; Ergon, Cem; Sisman, Ali Rıza
2018-01-01
The aim of this study is to evaluate and compare the analytical performance characteristics of the two creatinine methods based on the Jaffe and enzymatic methods. Two original creatinine methods, Jaffe and enzymatic, were evaluated on Architect c16000 automated analyzer via limit of detection (LOD) and limit of quantitation (LOQ), linearity, intra-assay and inter-assay precision, and comparability in serum and urine samples. The method comparison and bias estimation using patient samples according to CLSI guideline were performed on 230 serum and 141 urine samples by analyzing on the same auto-analyzer. The LODs were determined as 0.1 mg/dL for both serum methods and as 0.25 and 0.07 mg/dL for the Jaffe and the enzymatic urine method respectively. The LOQs were similar with 0.05 mg/dL value for both serum methods, and enzymatic urine method had a lower LOQ than Jaffe urine method, values at 0.5 and 2 mg/dL respectively. Both methods were linear up to 65 mg/dL for serum and 260 mg/dL for urine. The intra-assay and inter-assay precision data were under desirable levels in both methods. The higher correlations were determined between two methods in serum and urine (r=.9994, r=.9998 respectively). On the other hand, Jaffe method gave the higher creatinine results than enzymatic method, especially at the low concentrations in both serum and urine. Both Jaffe and enzymatic methods were found to meet the analytical performance requirements in routine use. However, enzymatic method was found to have better performance in low creatinine levels. © 2017 Wiley Periodicals, Inc.
Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana
2014-01-01
Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.
Improvement in the stability of serum samples stored in an automated refrigerated module.
Parra-Robert, Marina; Rico-Santana, Naira; Alcaraz-Quiles, José; Sandalinas, Silvia; Fernández, Esther; Falcón, Isabel; Pérez-Riedweg, Margarita; Bedini, Josep Lluís
2016-12-01
In clinical laboratories it is necessary to know for how long the analytes are stable in the samples with specific storage conditions. Our laboratory has implemented the new Aptio Automation System (AAS) (Siemens Healthcare Diagnostics) where the analyzed samples are stored in a refrigerated storage module (RSM) after being sealed. The aim of the study was to evaluate the stability of serum samples with the AAS and comparing the results with a previous study using a conventional refrigerated system. Serum samples from a total of 50 patients were collected and for each of them 27 biochemical analytes were analyzed. The samples were divided in 5 sets of 10 samples. Each set was re-analyzed at one of the following times: 24, 48, 72, 96 and 120h. Stability was evaluated according to the Total Limit of Change (TLC) criteria, which combine both analytical and biologic variation. A total of 26 out of 27 analytes were stable at the end of the study according to TLC criteria. Lactate dehydrogenase was not stable at 48h observing a decrease in its concentration until the end of the study. In the previous study (conventional storage system) 9 biochemical analytes were not stable with an increase of their levels due to the evaporation process. The RSM connected to the AAS improves the stability of serum samples. This system avoids the evaporation process due to the sealing of samples and allows better control of the samples during their storage. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Sankar, Surya; Harshan, Hiron M; Somarajan, S R; Srivastava, S K
2010-06-01
A recombinant leptospiral lipoprotein, LigB, was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLigB IgG ELISA). The standard reference test (Microscopic agglutination test, MAT) of 200 serum samples from cattle suspected of leptospirosis showed that 95 (47.5%) samples had positive agglutination titres, which ranged from 100 to 1600. In rLigB IgG ELISA, 49% of the samples were positive. Sensitivity of IgG ELISA for 95 bovine sera, which had MAT titres of greater than or equal to 100, were 100%. ELISA showed a specificity of 97.1% with 105 bovine sera, which were negative at a 1:50 dilution in MAT for Leptospira interrogans serovars. The results of ELISA and MAT correspond very good. When analytical specificity of IgG ELISA was evaluated using bovine serum samples from animals showing the serum antibodies to other pathogens, no cross-reaction was observed. Thus the recombinant LigB IgG ELISA can be used instead of the MAT as an aid to the diagnosis of bovine leptospirosis. Copyright 2009. Published by Elsevier India Pvt Ltd.
Yang, Mei; Wang, Zhuoya; Hao, Wei; Wang, Yanfang; Huang, Li; Cai, Jianpiao; Jiang, Lingxiao; Che, Xiaoyan; Zhong, Xiaozhu; Yu, Nan
2014-05-01
To establish two double-antigen sandwich ELISA systems to detect anti-Afmp1cr and Afmp2cr antibodies of Aspergillus fumigatus. Recombinant Afmp1cr and Afmp2cr proteins of A.fumigatus expressed in Pichia pastoris were obtained. Double-antigen sandwich ELISA systems for detecting specific anti-Afmp1cr and anti-Afmp2cr antibodies were developed after chessboard titrating to determine the appropriate concentrations of the recombinant proteins and HRP-labeled proteins. The sensitivity of the assay was evaluated using serum samples of rabbits immunized with Afmp1cr and Afmp2cr. The specificity of the assay was evaluated by detecting serum samples from healthy donors and patients with other pathogenic fungal and baterial infections. The performance of the two ELISA kits was furthered evaluated using serum samples from patients with suspected Aspergillus infection. The established ELISA kits were capable of detecting anti-Afmp1cr and anti-Afmp2cr antibodies in immunized rabbit serum at the maximum dilutions of 800 and 3200, respectively. No cross-reactivity was observed in detecting serum from patients with other pathogenic fungal or bactetial infections. Both of the two kits yielded positive results in sera from two established Aspergillus-infected cases and a suspected case. Two antibody-capture ELISA kits were developed for the laboratory diagnosis of A.fumigatus infection and can be potentially useful in the clinical diagnosis of Aspergillosis infections.
Panyasing, Yaowalak; Kedkovid, Roongtham; Thanawongnuwech, Roongroje; Kittawornrat, Apisit; Ji, Ju; Giménez-Lirola, Luis; Zimmerman, Jeffrey
2018-03-01
Early recognition and rapid elimination of infected animals is key to controlling incursions of classical swine fever virus (CSFV). In this study, the diagnostic characteristics of 10 CSFV assays were evaluated using individual serum (n = 601) and/or oral fluid (n = 1417) samples collected from -14 to 28 days post inoculation (DPI). Serum samples were assayed by virus isolation (VI), 2 commercial antigen-capture enzyme-linked immunosorbent assays (ELISA), virus neutralization (VN), and 3 antibody ELISAs. Both serum and oral fluid samples were tested with 3 commercial real-time reverse transcription-polymerase chain reaction (rRT-PCR) assays. One or more serum samples was positive by VI from DPIs 3 to 21 and by antigen-capture ELISAs from DPIs 6 to 17. VN-positive serum samples were observed at DPIs ≥ 7 and by antibody ELISAs at DPIs ≥ 10. CSFV RNA was detected in serum samples from DPIs 2 to 28 and in oral fluid samples from DPIs 4 to 28. Significant differences in assay performance were detected, but most importantly, no single combination of sample and assay was able to dependably identify CSFV-inoculated pigs throughout the 4-week course of the study. The results show that effective surveillance for CSFV, especially low virulence strains, will require the use of PCR-based assays for the detection of early infections (<14 days) and antibody-based assays, thereafter. Copyright © 2018 Elsevier B.V. All rights reserved.
METHOD FOR MICRORNA ISOLATION FROM CLINICAL SERUM SAMPLES
Li, Yu; Kowdley, Kris V.
2012-01-01
MicroRNAs are a group of intracellular non-coding RNA molecules that have been implicated in a variety of human diseases. Due to their high stability in blood, microRNAs released into circulation could be potentially utilized as non-invasive biomarkers for diagnosis or prognosis. Current microRNA isolation protocols are specifically designed for solid tissues and are impractical for biomarker development utilizing small-volume serum samples on a large scale. Thus, a protocol for microRNA isolation from serum is needed to accommodate these conditions in biomarker development. To establish such a protocol, we developed a simplified approach to normalize sample input by using single synthetic spike-in microRNA. We evaluated three commonly used commercial microRNA isolation kits for the best performance by comparing RNA quality and yield. The manufacturer’s protocol was further modified to improve the microRNA yield from 200 μL of human serum. MicroRNAs isolated from a large set of clinical serum samples were tested on the miRCURY LNA real-time PCR panel and confirmed to be suitable for high-throughput microRNA profiling. In conclusion, we have established a proven method for microRNA isolation from clinical serum samples suitable for microRNA biomarker development. PMID:22982505
Davies, R H; Heath, P J; Coxon, S M; Sayers, A R
2003-01-01
Monitoring for Salmonella in slaughter pigs is important to enable targeted control measures to be applied on problem farms and at the abattoir. The aim of this study was to determine whether pooled serum and meat juice could be used to identify finishing pig herds with a high prevalence of infection. Samples of meat juice, serum, caecal contents, carcase swabs and pooled faeces from pig pens were taken from 20 commercial pig finishing farms and comparisons were made between the results of Salmonella culture, individual ELISA tests on serum and meat juice and pooled samples of serum and meat juice. Salmonella was isolated from samples from 19 of 20 farms. None of the ELISA tests showed a statistically significant correlation with caecal carriage of Salmonella or contamination of carcases. Serum mean optical density (O.D.) from pools of five, 10 or 20 sera showed a significant correlation with the Salmonella status of farm pen faeces. All pooled serum O.D. and sample/positive control ratio results correlated significantly with the results of the conventional individual sample ELISA. There was a statistically significant correlation between the incidence of Salmonella in farm pen pooled faeces and the prevalence of Salmonella in caeca of slaughter pigs. The results show a generally poor correlation between serological and bacteriological results but pooled serum or meat juice samples could be used as a cheaper substitute for serological screening of farms for Salmonella than individual samples. The availability of a cheaper test should allow the costs of Salmonella monitoring of pig farms to be reduced or allow more regular testing to enhance the designation of farm Salmonella risk status.
Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A
1993-01-01
The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.
Gonçalves, Maria Gisele; Higa, Fábio Takenori; Castilho, Euclides Ayres; Ibarz-Pavón, Ana Belén; Sacchi, Claudio Tavares
2017-01-01
Background The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo’s national surveillance for routine diagnosis were selected for this study. Methods The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF) samples processed using our laboratory’s standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer’s instructions. Results The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory’s standard methodology, results showed high concordance, with Kappa index ranges of 0.9877–1.00 for CSF, and 0.8004–1.00 for serum samples. Conclusion The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow obtaining valuable epidemiological information that would otherwise be lost. PMID:28235065
The WHI offers an opportunity to evaluate ovarian cancer markers and screening decision rules developed and validated in EDRN CVC Studies 2 and 3 in women who were not being screened. It is particularly well suited to validation of risk markers, since many serum samples were drawn well before clinical diagnosis of cancer in the WHI cohorts. A strategy is needed to identify from among the general population of women over the age of 50 those at high-risk for a diagnosis of ovarian/fallopian tube cancer so that they can be referred for appropriate surveillance, imaging or surgical consult. Tools to identify high-risk women will be investigated including serum markers CA125, HE4, MSLN, and MMP7 and epidemiologic risk factors. We will optimize decision rules using stored serum samples from the WHI OS and conduct a simulated prospective validation using stored serum samples from the WHI CT. Decision rules to select women for ovarian cancer screening will be investigated as well as decision rules for use in ovarian cancer screening.
Reassessment of the Access Testosterone chemiluminescence assay and comparison with LC-MS method.
Dittadi, Ruggero; Matteucci, Mara; Meneghetti, Elisa; Ndreu, Rudina
2018-03-01
To reassess the imprecision and Limit of Quantitation, to evaluate the cross-reaction with dehydroepiandrosterone-sulfate (DHEAS), the accuracy toward liquid chromatography-mass spectrometry (LC-MS) and the reference interval of the Access Testosterone method, performed by DxI immunoassay platform (Beckman Coulter). Imprecision was evaluated testing six pool samples assayed in 20 different run using two reagents lots. The cross-reaction with DHEAS was studied both by a displacement curve and by spiking DHEAS standard in two serum samples with known amount of testosterone. The comparison with LC-MS was evaluated by Passing-Bablock analysis in 21 routine serum samples and 19 control samples from an External Quality Assurance (EQA) scheme. The reference interval was verified by an indirect estimation on 2445 male and 2838 female outpatients. The imprecision study showed a coefficient of variation (CV) between 2.7% and 34.7% for serum pools from 16.3 and 0.27 nmol/L. The value of Limit of Quantitation at 20% CV was 0.53 nmol/L. The DHEAS showed a cross-reaction of 0.0074%. A comparison with LC-MS showed a trend toward a slight underestimation of immunoassay vs LC-MS (Passing-Bablock equations: DxI=-0.24+0.906 LCMS in serum samples and DxI=-0.299+0.981 LCMS in EQA samples). The verification of reference interval showed a 2.5th-97.5th percentile distribution of 6.6-24.3 nmol/L for male over 14 years and <0.5-2.78 nmol/L for female subjects, in accord with the reference intervals reported by the manufacturer. The Access Testosterone method could be considered an adequately reliable tool for the testosterone measurement. © 2017 Wiley Periodicals, Inc.
Zhao, Mei-Fen; Huang, Peng; Ge, Chun-Lin; Sun, Tao; Ma, Zhi-Gang; Ye, Fei-Fei
2016-02-28
To identify conjugated bile acids in gallbladder bile and serum as possible biomarkers for cholesterol polyps (CPs) and adenomatous polyps (APs). Gallbladder bile samples and serum samples were collected from 18 patients with CPs (CP group), 9 patients with APs (AP group), and 20 patients with gallstones (control group) from March to November, 2013. High performance liquid chromatography (HPLC) assay with ultraviolent detection was used to detect the concentration of 8 conjugated bile acids (glycocholic acid, GCA; taurocholic acid, TCA; glycochenodeoxycholic acid, GCDCA; taurochenodeoxycholic acid, TCDCA; glycodeoxycholic acid, GDCA; taurodeoxycholic acid, TDCA; taurolithocholic acid, TLCA; tauroursodeoxycholic acid, TUDCA) in bile samples and serum samples. The diagnostic efficacy of serum GCA, GCDCA and TCDCA was evaluated. These 8 conjugated bile acids in gallbladder bile and serum were completely identified within 10 minutes with good linearity (correlation coefficient: R>0.9900; linearity range: 3.91-500 µg/mL). Among these conjugated bile acids, the levels of gallbladder bile GCDCA and TCDCA in the CP group were significantly higher than those in the AP group (p<0.05). Furthermore, serum GCDCA and TCDCA as well as GCA were significantly higher in the AP group than the CP group (p<0.05). Serum GCDCA alone (≤12 µg/mL) had relatively better diagnostic efficacy than the other conjugated bile acids. The levels of serum GCA, GCDCA and TCDCA may be valuable for differentiation of APs and CPs.
Klohonatz, Kristin M; Cameron, Ashely D; Hergenreder, Joanna R; da Silveira, Juliano C; Belk, Aeriel D; Veeramachaneni, D N R; Bouma, Gerrit J; Bruemmer, Jason E
2016-12-01
During early pregnancy, the conceptus and mare communicate to establish pregnancy. Cell-secreted vesicles (e.g., exosomes) have been reported in serum. Exosomes contain bioactive materials, such as miRNA, that can mediate cell responses. We hypothesized that a) exosomes are present in mare circulation and quantity varies with pregnancy status, b) exosomes contain miRNAs unique to pregnancy status, and c) miRNAs target pathways in endometrium based upon pregnancy status of the mare. First, serum samples were obtained from mares in a crossover design, with each mare providing samples from a pregnant and nonmated control cycle (n = 3/sample day) on Days 12, 14, 16, and 18 postovulation. Flow cytometry revealed the presence of serum microvesicles in mares in two different-sized populations (greater than or less than 100 nm), validated by transmission electron microscopy. Second, serum was collected on Days 9, 11, and 13 (n = 4/day), and endometrial biopsies were collected on Days 11 and 13 (n = 3/day) from pregnant and nonmated mares. Total RNA from serum exosomes was evaluated with quantitative RT-PCR using equine-specific miRNA sequences. A total of 12 miRNAs were found in different quantities on the specified days. Pathway analysis suggested that miRNAs targeted focal adhesion molecules (FAMs). Transcripts corresponding to FAMs were evaluated in endometrial biopsies. Protein levels and localization for PAK6 and RAF1 were further evaluated. Our data suggest that serum exosomes contain miRNA that differ based upon pregnancy status, and may affect mRNA expression related to focal adhesion pathway in the endometrium, with a potential role in maternal recognition of pregnancy. © 2016 by the Society for the Study of Reproduction, Inc.
Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D
2016-05-01
A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG < 10 g/L, Brix % ≤ 8.5% showed optimal sensitivity (100%) and specificity (89.2%) to predict FPT. At the same IgG cut-point, an STP value of ≤ 52 g/L showed a similar sensitivity (100%) and specificity (80.4%) to predict FPT. Brix refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.
Pedroza, Kelly C M C; de Matos, Sócrates B; de Moura, Daniel L; Oliveira, Mônica B B; Araújo, Marco A S; Nascimento, Roberto J M; Lima, Fernanda W M
2013-10-01
Galactomannan (GM) was recently included in consensus guidelines as an indirect mycological criterion for the diagnosis of invasive aspergillosis. Currently, there is an enzyme immunoassay available to detect GM in biological samples, the Platelia™ Aspergillus EIA. In this study, the reproducibility of positive results obtained using this assay was evaluated using serum samples from neutropenic patients. A trend toward lower values was observed, and 55 %(27/49) of positive results were negative after retesting. A low reproducibility of positive results for the detection of GM in serum was observed.
Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio
2012-01-01
Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296
Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics
2011-01-01
Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin) make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent) displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma) in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers. PMID:21554704
Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong; Li, Ning
2016-12-01
Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC ( n = 65) and healthy control subjects ( n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC.
Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong
2016-01-01
Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC (n = 65) and healthy control subjects (n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC. PMID:27885040
Evaluation of YB-1 levels in patients with endometriosis.
Ahrens, Thorben; Silveira, Cassia G T; Banz-Jansen, Constanze; Rody, Achim; Hornung, Daniela
2015-08-01
The objective of this study is the evaluation of serum YB-1 levels in the diagnosis of endometriosis. Serum samples of 12 patients with histologically confirmed endometriosis and of 10 control patients were collected. Western blot analysis was used to assess serum YB-1 levels. Groups were compared with Student's t-test or, if not normally distributed, with the Mann-Whitney test. Sensitivity and specificity for the potential diagnostic performance of serum YB-1 were assessed by receiver operating characteristic (ROC) curves. Serum YB-1 levels were significantly higher in patients with endometriosis (=0.004). The area under the curve was 0.867 (95% confidence interval 0.714-1.019) with sensitivity and specificity of 83.3% and 70% respectively. Serum YB-1 levels in patients with endometriosis are significantly higher compared to control patients and may be used as a potential diagnostic biomarker for endometriosis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Evaluation of automated assays for immunoglobulin G, M, and A measurements in dog and cat serum.
Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Caldin, Marco; Tecles, Fernando; Ceron, Jose J
2013-09-01
Measurements of immunoglobulins (Igs) in companion animals can be useful to detect deficiencies of the humoral immune system, that can be associated with opportunistic or chronic infections, or other immune-mediated disorders including B-cell neoplasms. The purpose of this study was to evaluate commercially available automated immunoturbidimetric assays designed for human IgG, M, and A measurements in canine and feline serum using species-specific calibrators. Canine and feline serum samples with different IgG, M, and A concentrations were used for the analytical validation of the assays. Intra- and inter-assay precision, linearity under dilution, spiking recovery, and limit of detection were determined. In addition, effects of lipemia, hemolysis, and bilirubinemia were evaluated. Finally, Ig concentrations were determined in small groups of diseased dogs and cats, and compared with healthy groups. Spiking recovery and linearity under dilution tests showed that the assays measured Igs in canine and feline serum samples precisely and accurately. Intra- and inter-assay imprecisions were lower than 15% in all cases. Significantly higher IgG, IgM, and IgA levels were observed in dogs with leishmaniasis, while dogs with pyometra showed a statistically significant increase in IgM and IgA concentrations in comparison with healthy dogs. Significantly higher IgG and IgM levels were observed in FIV-infected cats compared with healthy ones. The automated human Ig assays showed adequate precision and accuracy with serum samples from dogs and cats. Also, they were able to discriminate different concentrations of Igs in healthy and diseased animals. © 2013 American Society for Veterinary Clinical Pathology.
Korosue, Kenji; Murase, Harutaka; Sato, Fumio; Ishimaru, Mutsuki; Kotoyori, Yasumitsu; Nambo, Yasuo
2012-11-01
The object of this study was to evaluate the usefulness of measuring the differences in the values of the serum total protein (DVSTP) concentration of foals and the refractometry index (DVRI) of the milk of dams before and after nursing of the colostrum for assessing failure of passive transfer (FPT) in foals. Serum samples from 31 foals were collected before the first nursing and other 1 to 6 times between 4 and 24 hr after birth. Paired colostrum and milk samples were collected from 14 of their dams at the same time. Serum samples were analyzed for IgG concentration using a single radial immunodiffusion (SRID) test (98 samples) and total protein concentration using a temperature-compensating refractometer (98 samples). Colostrum and milk samples were analyzed for refractometry index (RI) using a Brix refractometer (71 samples). DVSTP concentration and DVRI were significantly correlated with serum IgG concentration. The negative predictive values (NPVs) of DVSTP concentration for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 98.2% and 91.3% when the cutoff value is set to 0.4 mg/dl and 0.8 mg/dl, respectively. Furthermore, the NPVs of DVRI for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 97.3% and 96.3% when the cutoff value is set to 6% and 10%, respectively. The results suggest that measurement of DVRI is useful in assessing FPT as an initial "stall-side" screening test, because it is easy, inexpensive to perform and allows for rapid interpretation.
Systematic evaluation of serum and plasma collection on the endogenous metabolome.
Zhou, Zhi; Chen, Yanhua; He, Jiuming; Xu, Jing; Zhang, Ruiping; Mao, Yan; Abliz, Zeper
2017-02-01
In metabolomics research, the use of different blood collection methods may influence endogenous metabolites. Ultra HPLC coupled with MS/MS was applied together with multivariate statistics to investigate metabolomics differences in serum and plasma samples handled by different anticoagulants. A total of 135 known representative metabolites were assessed for comprehensive evaluation of the effects of anticoagulants. Exogenous factors, including separation gel ingredients from the serum collection tubes and the anticoagulants, affected mass spectrometer detection. Heparin plasma yielded the best detection of different functional groups and is therefore the optimal blood specimen for metabolomics research, followed by potassium oxalate plasma.
Sá e Silva, Mariana; Swayne, David E
2012-09-01
Surveillance for low pathogenicity avian influenza virus (LPAIV) infections has primarily relied on labor-intensive collection and serological testing of serum, but for many poultry diseases, easier-to-collect yolk samples have replaced serum for surveillance testing. A time-course LPAIV infection study in layers was performed to evaluate the utility of antibody detection in serum vs. egg yolk samples. Layers inoculated with the LPAIV A/Bobwhite Quail/Pennsylvania/20304/98 (H7N2) were tested for antibody levels in the serum and egg yolk by using the agar gel immunodiffusion test (AGID), hemagglutination-inhibition test (HI), and a commercially available enzyme-linked immunosorbent assay (ELISA). Anti-influenza specific antibodies were detected in the serum as early as 7 days postinoculation (DPI), and the majority of the hens remained positive until 42 DPI. Antibodies in the egg yolk were first detected by AGID at 7 DPI, which was also the first day of detection in serum. However, the majority of the eggs were positive by all techniques at 11 DPI and remained positive until 42 DPI, at which time the number of AGID+ and HI+ samples declined slightly as compared to ELISA+ samples. These results suggest that egg yolk can be an alternative to serum for flock serological surveillance against LPAIV infections, and the three methods (AGID, HI, and ELISA) will give similar results for first 42 days after infection, although AGID may give earlier positive response.
McCracken, M M; Morrill, K M; Fordyce, A L; Tyler, H D
2017-10-01
Previous data have demonstrated that refractometers can be used to estimate serum IgG, and that a cut-point of 7.8% Brix should be used to identify failure of passive transfer (FPT) in 1-d-old Holstein calves. The objective of the present study was to validate the use of refractometry to estimate serum IgG concentrations and evaluate FPT in Jersey calves. Blood samples (n = 97) were obtained from 1- to 3-d-old Jersey calves and centrifuged at 3,300 × g for 20 min at 25°C. Serum was analyzed for % Brix, total protein (TP), and refractive index (nD) using a Sper Scientific Digital Refractometer (model #300036, Sper Scientific, Scottsdale, AZ) within 12 h of sampling. Samples were then frozen and later analyzed in the laboratory for IgG by radial immunodiffusion. The mean serum IgG concentration for all calves was 23.7 mg/mL (SD = 12.5), with a range of 2.3 to 65.5 mg/mL. Mean serum % Brix was 8.9 (SD = 1.1; range 6.5 to 12.0). Serum % Brix was moderately correlated with IgG concentration (r = 0.77). Total protein and IgG were moderately correlated (r = 0.790). Regression was used to determine cut-points for approximately 10, 12, and 14 mg of IgG/mL and to determine the sensitivity and specificity of refractometry to identify FPT (serum IgG <10 mg/mL at 24 h of life). Brix cut-points analyzed were 7.1, 7.3, and 7.6%; TP cut-points were 4.6, 5.0, and 5.5 g/dL; and nD cut-points were 1.34332, 1.34271, and 1.3448, respectively, for 10, 12, and 14 mg of IgG/mL. The 7.3% Brix and 4.6 g/dL TP cut-points resulted in the greatest percentage of samples being correctly classified. These data suggest that digital refractometry is an acceptable and rapid method to estimate immunoglobulin G in Jersey calf serum. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Semevolos, Stacy A; Reed, Shannon K; Schultz, Loren G
2013-01-01
To characterize serum trace mineral, sex steroid hormone, and vitamin D concentrations and identify factors associated with metacarpophalangeal and metatarsophalangeal hyperextension in llamas and alpacas. Serum samples from 79 llamas and 15 alpacas and owner survey data for 573 llamas and 399 alpacas. Serum samples were stored at -20°C until analysis and were evaluated for trace mineral, vitamin D, estradiol, progesterone, and testosterone concentrations. Information regarding age of onset, number of affected animals in herd, feed and supplements given, type of housing, and management practices was obtained in an owner survey. Higher serum zinc and iron concentrations were associated with metacarpophalangeal and metatarsophalangeal hyperextension in camelids, compared with controls. In summer and fall months, vitamin D concentrations were significantly higher in affected camelids than controls. Overall prevalence was 13.3% in llamas, compared with 0.7% in alpacas. No management factors were found to be predictive of this condition. No other factors examined were associated with metacarpophalangeal and metatarsophalangeal hyperextension. Despite similar supplementation practices and environmental conditions between affected and unaffected animals, an association of high serum zinc, iron, and vitamin D concentrations in affected camelids, compared with controls, may indicate differences of intake or absorption of dietary supplements.
Amoeba-Resisting Bacteria and Ventilator-Associated Pneumonia
La Scola, Bernard; Boyadjiev, Ioanna; Greub, Gilbert; Khamis, Atieh; Martin, Claude
2003-01-01
To evaluate the role of amoeba-associated bacteria as agents of ventilator-associated pneumonia (VAP), we tested the water from an intensive care unit (ICU) every week for 6 months for such bacteria isolates; serum samples and bronchoalveolar lavage samples (BAL) were also obtained from 30 ICU patients. BAL samples were examined for amoeba-associated bacteria DNA by suicide-polymerase chain reaction, and serum samples were tested against ICU amoeba-associated bacteria. A total of 310 amoeba-associated bacteria from10 species were isolated. Twelve of 30 serum samples seroconverted to one amoeba-associated bacterium isolated in the ICU, mainly Legionella anisa and Bosea massiliensis, the most common isolates from water (p=0.021). Amoeba-associated bacteria DNA was detected in BAL samples from two patients whose samples later seroconverted. Seroconversion was significantly associated with VAP and systemic inflammatory response syndrome, especially in patients for whom no etiologic agent was found by usual microbiologic investigations. Amoeba-associated bacteria might be a cause of VAP in ICUs, especially when microbiologic investigations are negative. PMID:12890321
Sawhney, Hemant; Kumar, C Anand
Oral cancer is currently the most frequent cause of cancer-related deaths, which is usually preceded by oral pre-cancerous lesions and conditions. Altered glycosylation of glycoconjugates, such as sialic acid, fucose, etc. are amongst the important molecular changes that accompany malignant transformation. The purpose of our study was to evaluate usefulness of serum Total Sialic Acid (TSA) and serum Lipid-Bound Sialic Acid (LSA) as markers of oral precancerous lesions and histopathologically correlating them with grades of epithelial dysplasia. Blood samples were collected from 50 patients with oral precancer (Leukoplakia & OSMF), 25 patients with untreated oral cancer and 25 healthy subjects. Serum sialic acid (total and lipid bound) levels were measured spectrophotometrically. Tissue samples from all the patients were evaluated for dysplasia. Serum levels of total and lipid bound sialic acid were significantly elevated in patients with oral precancer and cancer when compared with healthy subjects. Analysis of variance test documented that there is progressive rise in serum levels of sialic acid with the degree of dysplastic changes in oral precancer patients. We observed positive correlation between serum levels of the markers and the extent of malignant disease (TNM Clinical staging) as well as histopathological grades. The results suggested that serum levels of TSA and LSA progressively increases with grades of dysplasia in precancerous groups and cancer group, when compared with healthy controls. These glycoconjugates, especially LSA has the clinical utility in indicating a premalignant change.
Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan
2013-01-01
Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.
Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.
González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R
1988-02-01
The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.
Identification of New Biomarkers of Low-Dose GH Replacement Therapy in GH-Deficient Patients
Cruz-Topete, Diana; Jorgensen, Jens Otto L.; Christensen, Britt; Sackmann-Sala, Lucila; Krusenstjerna-Hafstrøm, Thomas; Jara, Adam; Okada, Shigeru
2011-01-01
Context: GH secretion peaks at puberty and continues to be secreted in adulthood, albeit at a declining rate. Profound GH deficiency (GHD) in adults with pituitary disease is associated with symptoms that improve with GH substitution, but it is important to tailor the GH dose to avoid overtreatment. Measurement of serum IGF-I levels is an important clinical tool in this regard, but it is well recognized that some patients receiving GH treatment do not show an increase in IGF-I. Objective: The objective of the study was to identify novel serum biomarkers of GH treatment in adults with GHD. Design and Patients: Eight patients with profound GHD as a consequence of a pituitary adenoma or its treatment were evaluated before and 3 months after GH replacement therapy (0.2–0.4 mg/d). Main Outcome Measures: Serum proteomic changes were studied using two-dimensional gel electrophoresis and mass spectrometry. Protein profiles were analyzed and compared in serum samples obtained before and after GH treatment. Results: The levels of six serum protein spots were significantly altered after GH substitution. These proteins were identified as five isoforms of haptoglobin (decreased in posttreatment samples) and one isoform of apolipoprotein A-I (increased in posttreatment samples). Importantly, changes in the levels of the identified proteins were associated with decreases in fat mass and increases in lean mass in all patients. These results were independent of serum IGF-I levels. Conclusions: Evaluation of the identified proteins provides a novel alternative to traditional markers of GH status, such as serum IGF-I levels, to assess GH therapy in GH deficient adults. PMID:21543428
Serum antileptospiral agglutinins in freshwater turtles from Southern Brazil
Silva, Éverton F; Seyffert, Núbia; Cerqueira, Gustavo M.; Leihs, Karl P.; Athanazio, Daniel A.; Valente, Ana L. S.; Dellagostin, Odir A.; Brod, Claudiomar S.
2009-01-01
In this study, we observed the presence of antileptospiral agglutinins in freshwater turtles of two urban lakes of Pelotas, Southern Brazil. Forty animals (29 Trachemys dorbigny and 11 Phrynops hilarii) were captured and studied. Attempts to isolate leptospires from blood and urine samples were unsuccessful. Serum samples (titer > 100) reactive to pathogenic strains were observed in 11 animals. These data encourage surveys of pet turtles to evaluate the risk of transmission of pathogenic leptospires to humans. PMID:24031348
Cavalleri, A; Colombo, C; Venturelli, E; Miceli, R; Mariani, L; Cornelli, U; Pala, V; Berrino, F; Secreto, G
2004-01-01
Measuring the free radical activity in serum samples from prospective studies is the best way to investigate the association between oxidative stress and human diseases. Prospective studies require the analysis of serum samples that have often been stored for a long time. Our study was designed to determine the effect of storage at -30 degrees C and -80 degrees C for two years on free radical activity. We analyzed the free radical activity by measuring circulating hydroperoxides in a pool of sera at baseline and after one day, one week, one month and 25 months of storage, using a photometric method (d-ROMs test). Measurements were performed in aliquots thawed only once at each time point and in aliquots frozen and thawed repeatedly over the study period. After two years we observed a small but statistically significant 4% decrease in the hydroperoxide concentration, which was substantially unaffected by storage temperatures and repeated freeze-thaw cycles. We also carried out the d-ROMs test in sera from ten apparently healthy volunteers at 2, 8, 24, and 48 hours after collection and storage at 4 degrees C and did not observe any significant variation. In conclusion, the d-ROMs test is a simple method suitable to evaluate the free radical activity in frozen serum samples after long-term storage.
Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio
2013-01-01
A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomson, S.; Wallace, A.M.; Cook, B.
1989-08-01
We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of thesemore » selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.« less
Isaza, Ramiro; Wiedner, Ellen; Hiser, Sarah; Cray, Carolyn
2014-09-01
Acute phase protein (APP) immunoassays and serum protein electrophoresis (SPEP) are assays for evaluating the inflammatory response and have use as diagnostic tools in a variety of species. Acute phase proteins are markers of inflammation that are highly conserved across different species while SPEP separates and quantifies serum protein fractions based on their physical properties. In the current study, serum samples from 35 clinically healthy Asian elephants (Elephas maximus) were analyzed using automated assays for C-reactive protein, serum amyloid A, and haptoglobin and SPEP. Robust methods were used to generate reference intervals for the APPs: C-reactive protein (1.3-12.8 mg/l), serum amyloid A (0-47.5 mg/l), and haptoglobin (0-1.10 mg/ml). In addition, SPEP was performed on these samples to establish reference intervals for each protein fraction. A combination of APPs and SPEP measurements are valuable adjunctive diagnostic tools in elephant health care. © 2014 The Author(s).
Biagini, R E; Sammons, D L; Smith, J P; Page, E H; Snawder, J E; Striley, C A F; MacKenzie, B A
2004-08-01
To evaluate potential exposure to Bacillis anthracis (Ba) spores in sampling/decontamination workers in the aftermath of an anthrax terror attack. Fifty six serum samples were obtained from workers involved in environmental sampling for Ba spores at the American Media, Inc. (AMI) building in Boca Raton, FL after the anthrax attack there in October 2001. Nineteen sera were drawn from individuals both pre-entry and several weeks after entrance into the building. Nine sera each were drawn from unique individuals at the pre-entry and follow up blood draws. Thirteen donor control sera were also evaluated. Individuals were surveyed for Ba exposure by measurement of serum Ba anti-protective antigen (PA) specific IgG antibodies using a newly developed fluorescent covalent microsphere immunoassay (FCMIA). Four sera gave positive anti-PA IgG results (defined as anti-PA IgG concentrations > or = the mean microg/ml anti-PA IgG from donor control sera (n = 13 plus 2 SD which were also inhibited > or = 85% when the serum was pre-adsorbed with PA). The positive sera were the pre-entry and follow up samples of two workers who had received their last dose of anthrax vaccine in 2000. It appears that the sampling/decontamination workers of the present study either had insufficient exposure to Ba spores to cause the production of anti-PA IgG antibodies or they were exposed to anthrax spores without producing antibody. The FCMIA appears to be a fast, sensitive, accurate, and precise method for the measurement of anti-PA IgG antibodies.
Burns, J; Hou, S; Riley, C B; Shaw, R A; Jewett, N; McClure, J T
2014-01-01
Rapid, economical, and quantitative assays for measurement of camelid serum immunoglobulin G (IgG) are limited. In camelids, failure of transfer of maternal immunoglobulins has a reported prevalence of up to 20.5%. An accurate method for quantifying serum IgG concentrations is required. To develop an infrared spectroscopy-based assay for measurement of alpaca serum IgG and compare its performance to the reference standard radial immunodiffusion (RID) assay. One hundred and seventy-five privately owned, healthy alpacas. Eighty-two serum samples were collected as convenience samples during routine herd visits whereas 93 samples were recruited from a separate study. Serum IgG concentrations were determined by RID assays and midinfrared spectra were collected for each sample. Fifty samples were set aside as the test set and the remaining 125 training samples were employed to build a calibration model using partial least squares (PLS) regression with Monte Carlo cross validation to determine the optimum number of PLS factors. The predictive performance of the calibration model was evaluated by the test set. Correlation coefficients for the IR-based assay were 0.93 and 0.87, respectively, for the entire data set and test set. Sensitivity in the diagnosis of failure of transfer of passive immunity (FTPI) ([IgG] <1,000 mg/dL) was 71.4% and specificity was 100% for the IR-based method (test set) as gauged relative to the RID reference method assay. This study indicated that infrared spectroscopy, in combination with chemometrics, is an effective method for measurement of IgG in alpaca serum. Copyright © 2014 by the American College of Veterinary Internal Medicine.
NASA Astrophysics Data System (ADS)
Treado, Patrick J.; Stewart, Shona D.; Smith, Aaron; Kirschner, Heather; Post, Christopher; Overholt, Bergein F.
2016-03-01
Colorectal cancer (CRC) is the third most common cancer in men and women in the United States. Raman Molecular Imaging (RMI) is an effective technique to evaluate human tissue, cells and bodily fluids, including blood serum for disease diagnosis. ChemImage Corporation, in collaboration with clinicians, has been engaged in development of an in vitro diagnostic Raman assay focused on CRC detection. The Raman Assay for Colorectal Cancer (RACC) exploits the high specificity of Raman imaging to distinguish diseased from normal dried blood serum droplets without additional reagents. Pilot Study results from testing of hundreds of biobank patient samples have demonstrated that RACC detects CRC with high sensitivity and specificity. However, expanded clinical trials, which are ongoing, are revealing a host of important preanalytical considerations associated with sample collection, sample storage and stability, sample shipping, sample preparation and sample interferents, which impact detection performance. Results from recent clinical studies will be presented.
Ohtaki, Ushio; Ozawa, Hiroshi; Ishizuka, Takehiro; Kamiishi, Akiko; Sasaki, Kyoko; Nakajima, Suemi; Katayama, Ayako; Arimoto, Kiyoshi; Yagihashi, Tatsuhiko; Kimiya, Satoshi
2012-09-01
The nutritive evaluation and the serum carnitine values were measured for persons with severe motor and intellectual disabilities with enteral (tube) feeding. In Shimada Rehabilitation Center, twenty one people who had serum albumin levels of 3.4 g/dl or less, and were taking nutrition with enteral (tube) feeding, were tested. Body weight, blood samples, and serum carnitine levels were measured. The total carnitine value was less than the standard value in 19 patients. The total carnitine value decreased in the group taking valporate sodium (VPA), compared to the values from the group non-taking VPA. From our evaluation, we think that daily carnitine supplements is essential for persons with sever motor and intellectual disabilities taking VPA to maintain carnitine levels in the blood, and regular urine test should be done for earlier detection secondary lack complications from the secondary lack of carnitine.
NASA Astrophysics Data System (ADS)
Buoso, M. C.; Ceccato, D.; Moschini, G.; Bernardini, D.; Testoni, S.; Torboli, A.; Valdes, M.
2001-11-01
The assessment of selenium status of livestock plays an important role in the production of medicine since low serum Se levels influence disease resistance in ruminants. It has been proved that Se deficiency may cause muscular dystrophy, cardiomyopathy and even death. Serum level has been widely used to evaluate the Se short-term status in animals since there is a good association between serum Se level and the dietary intake of the element over a wide range. The purpose of this work was to determine the Se serum concentration in a population of 78 sucking 2-month-old calves, in order to corroborate a clinical diagnosis of severe deficiency status. The samples were analyzed by total reflection X-ray fluorescence (TXRF) at the ITAL STRUCTURES Research Laboratory. The results obtained from the serum samples presented Se concentrations varying from 10 to 66 ng/ml. The comparison between the obtained values and the expected serum selenium values (60-80 ng/ml), confirmed a mild to severe deficiency status in the investigated population.
Tuerxunyiming, Muhadasi; Xian, Feng; Zi, Jin; Yimamu, Yilihamujiang; Abuduwayite, Reshalaiti; Ren, Yan; Li, Qidan; Abudula, Abulizi; Liu, SiQi; Mohemaiti, Patamu
2018-01-05
Maturity-onset diabetes of the young (MODY) is an inherited monogenic type of diabetes. Genetic mutations in MODY often cause nonsynonymous changes that directly lead to the functional distortion of proteins and the pathological consequences. Herein, we proposed that the inherited mutations found in a MODY family could cause a disturbance of protein abundance, specifically in serum. The serum samples were collected from a Uyghur MODY family through three generations, and the serum proteins after depletion treatment were examined by quantitative proteomics to characterize the MODY-related serum proteins followed by verification using target quantification of proteomics. A total of 32 serum proteins were preliminarily identified as the MODY-related. Further verification test toward the individual samples demonstrated the 12 candidates with the significantly different abundance in the MODY patients. A comparison of the 12 proteins among the sera of type 1 diabetes, type 2 diabetes, MODY, and healthy subjects was conducted and revealed a protein signature related with MODY composed of the serum proteins such as SERPINA7, APOC4, LPA, C6, and F5.
Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D
2006-03-01
Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.
Semevolos, Stacy A; Reed, Shannon K
2011-04-01
To evaluate molecular and histologic characteristics of the superficial digital flexor tendon (SDFT), deep digital flexor tendon (DDFT), and suspensory ligament (SL) and assess trace-mineral concentrations in serum, liver, and hair of juvenile llamas with metacarpophalangeal and metatarsophalangeal joint hyperextension. 12 juvenile llamas (6 with bilateral hyperextension of metacarpophalangeal joints, metatarsophalangeal joints, or both and 6 clinically normal control llamas). Radiography and ultrasonography of metacarpophalangeal and metatarsophalangeal regions were performed. Llamas were euthanized, and SDFT, DDFT, and SL samples were collected for histologic evaluation of collagen and elastin content and orientation, proteoglycan content, and collagen type III immunohistochemistry. Total RNA was isolated from SL tissue, and gene expression of collagen types I and III, lysyl oxidase, and matrix metalloproteinase-13 was evaluated via real-time quantitative reverse transcriptase PCR assay. Liver, serum, and hair samples were evaluated for trace mineral content. Collagen type III gene expression and proteoglycan content were significantly increased in SL samples of affected juvenile llamas, compared with those of control llamas. No difference was detected in collagen and elastin content and orientation or in gene expression of collagen type I, lysyl oxidase, or matrix metalloproteinase-13 between groups. Affected llamas had significantly increased serum molybdenum and decreased liver cobalt concentrations, compared with values for control llamas. Increased collagen type III gene expression and proteoglycan content in SL samples of affected juvenile llamas provided evidence of ongoing SL matrix repair. Trace mineral differences may have been attributable to dietary imbalances in affected llamas.
Global analysis of 1H-NMR spectra of serum is an appealing approach for the rapid detection of cancer. To evaluate the usefulness of this method in distinguishing between mammary tumor-bearing mice and healthy controls, we conducted 1H-NMR metabonomic analyses on serum samples ob...
Cremer, N E; Cossen, C K; Hanson, C V; Shell, G R
1982-01-01
Several methods for evaluating and reporting enzyme immunoassay (EIA) determinations of antibody to herpes simplex virus derived from one dilution of single serum samples were studied. An EIA ratio method for serological evidence of current infection from paired serum samples was also evaluated. Optical density (OD) of the reaction at a 1:100 serum dilution and estimated titers obtained by reference of the OD of the serum dilution to a standard curve were compared to the corresponding plotted EIA titer obtained by titration to endpoint. Neither the OD per se nor the estimated titer was completely predictive of the plotted titer (correlation coefficient [r] of 0.824 and 0.817, respectively), and they provided only a semiquantitative measurement of antibody concentration. For an antibody status report, however, OD would be sufficient if related to the cutoff value as an EIA index (OD of sample divided by cutoff OD for positive specimens). The OD of the EIA reaction at a single dilution (1:5) of cerebrospinal fluid, on the other hand, correlated quite well with the titer obtained by titration (r = 0.950). For serological diagnosis of current infection, the OD ratio of convalescence-phase/acute-phase sera was determined at several dilutions. A ratio of greater than or equal to 1.54 was calculated as a reliable index for a significant rise in antibody concentration and compatible with current infection. By determining the convalescent-phase/acute-phase serum ratio at two dilutions, 1:100 and 1:1,000, the EIA ratio method appeared to be a sensitive as or more sensitive than, complement fixation in diagnosing current infection. PMID:6284791
Fox, Maureen; Brieva, Claudia; Moreno, Carlos; MacWilliams, Peter; Thomas, Chet
2008-12-01
The white-footed tamarin (Saguinus leucopus) is an endangered primate that lives in a small forest corridor in northern Colombia, South America. Hematologic and serum biochemistry reference values are important tools in evaluating the health of the white-footed tamarin and serve to promote the survival of this species. The purpose of this study was to establish diagnostically important hematologic and serum biochemistry reference values for healthy white-footed tamarins and to determine whether there was significant variation with respect to age class (juveniles, adults), gender, and housing facility. Blood samples were collected for hematologic and serum biochemistry measurements from 29 wild-caught captive tamarins during February and April 2005, housed at three different facilities in central Colombia. Hematology and serum biochemistry values were similar in adults and juveniles. Female white-footed tamarins had absolute reticulocyte counts that were lower than those of male tamarins and males had lower serum chloride concentrations than female tamarins. Mean values for hemoglobin, mean cell hemoglobin, serum total protein, albumin, glucose, and alkaline phosphatase varied among the three housing facilities. Twenty-two of the 29 tamarins sampled were microfilaria-positive and had significantly higher mean serum alkaline phosphatase concentrations. Among the 29 tamarins sampled in this study, serum values for mean alkaline phosphatase and creatine kinase concentrations were higher than reported values for other mammals. The reference intervals determined in this study were comparable to normal ranges reported for other members of the family Callitrichidae.
Li, Jingguang; Guo, Feifei; Wang, Yuxin; Zhang, Jialing; Zhong, Yuxin; Zhao, Yunfeng; Wu, Yongning
2013-03-01
Because of the disadvantages of invasive sampling, it is desirable to explore non-invasive matrices for human biomonitoring of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The aim of this study was to evaluate the application of nail, hair and urine for human biomonitoring of PFOS and PFOA. The concentrations of PFOS and PFOA in matched nail, hair, urine and serum samples collected from 64 donors were measured. The chemicals of interest were detected with high detection frequency in these matrices (90%-100%) except for PFOA in urine samples (56%). Generally, the gender influences on the levels of PFOS and PFOA in these non-invasive matrices were in agreement with that in serum. For PFOS, the coefficients of Spearman correlation between serum samples and nail, hair and urine samples were 0.786 (p<0.001), 0.545 (p<0.001) and 0.302 (p<0.05), respectively. For PFOA, the correlation was only observed between nail samples and serum samples with a correlation coefficient of 0.299 (p<0.05). The results suggested that nail has more potential than hair and urine to be applied in human biomonitoring for PFOS and PFOA in general populations. Copyright © 2013 Elsevier Ltd. All rights reserved.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-07
To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-01
AIM: To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). METHODS: Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn’s disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student’s t test (α = 0.05). RESULTS: The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. CONCLUSION: NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission. PMID:24415869
NASA Astrophysics Data System (ADS)
Nixon, David E.; Neubauer, Kenneth R.; Eckdahl, Steven J.; Butz, John A.; Burritt, Mary F.
2003-01-01
A Dynamic Reaction Cell™ inductively coupled plasma mass spectrometer (DRC-ICP-MS) was evaluated for the determination of selenium in serum and urine. Reaction cell conditions were evaluated for the suppression of Ar 2+ dimer at m/ z 78 and 80 using methane as the reaction gas. A diluent containing 10% ethanol, 1% nitric acid, 0.5% Triton X-100 with gallium and yttrium internal standards was used to dilute urine and serum samples. Instrument response calibration was achieved by using aqueous acidic standards spiked into a urine matrix. Slopes for aqueous inorganic selenium, seleno- DL-cystine, seleno- DL-methionine and trimethylselenonium iodide spiked into urine and serum matrices were nearly identical. In general, reagent blank readings and detection limits were significantly lower in the DRC mode (reaction cell pressurized) than the standard mode (cell vented). Average results for the analysis of National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1598 bovine serum (attained over 13 days) are: 43.8±3.6 μg Se/l. Reference concentration is 43.6±3.6 μg Se/l. For NIST SRM 2670 Normal Urine the DRC-ICP-MS results are 30.7±4.6 μg Se/l with a certified concentration of 30±8 μg Se/l. For NIST SRM 2670 Elevated Urine the DRC-ICP-MS results are 463±35 μg Se/l with a certified concentration of 460±30 μg Se/l. The DRC-ICP-MS results for selenium determinations in urine and serum survey samples from the Institut National de Sante Publique du Quebec were compared with the reference concentrations and results produced by conventional ICP-MS. While conventional ICP-MS gave acceptable results for survey samples, DRC-ICP-MS gave excellent results for both urine and sera. Closer correlation was observed for DRC-ICP-MS results with target concentrations than with conventional ICP-MS.
Tong, Tom K.; Kong, Zhaowei; Lin, Hua; Lippi, Giuseppe; Zhang, Haifeng; Nie, Jinlei
2013-01-01
This study investigated the 1-year longitudinal effect of professional training in adolescent runners on redox balance during intense endurance exercise. Changes in selected serum oxidant and antioxidant status in response to a 21-km running time trial in 10 runners (15.5 ± 1.3 years) undergoing professional training were evaluated twice in 12 months (pre- and post-evaluation). Venous blood samples were collected immediately before and 4-h following the 21-km run for analysis of serum concentrations of thiobarbituric acid-reactive substances (TBARS), xanthine oxidase (XO), catalase (CAT), reduced glutathione (GSH), superoxide dismutase (SOD), and total antioxidant capacity (T-AOC). In pre-evaluation trial, serum TBARS and SOD decreased after the 21-km run (p < 0.05) while XO, GSH, CAT and TAOC were unchanged. In post-evaluation trial, serum TBARS and SOD decreased, whereas XO and CAT increased post-exercise (p < 0.05). Furthermore, pre-exercise serum T-AOC, post-exercise serum XO, CAT, T-AOC (p < 0.05), and GSH (p = 0.057) appeared to be higher than the corresponding pre-evaluation values. The current findings suggest that a professional training regime in adolescent runners is not likely to jeopardize the development of their antioxidant defense. However, uncertainties in the maintenance of redox balance in runners facing increased exercise-induced oxidative stress as a consequence of training-induced enhancement of exercise capacity await further elucidation. PMID:23880864
Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J
2010-10-01
The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.
Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J.
2010-01-01
The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study. PMID:21197228
[Effect evaluation of three ELISA kits in detection of fasciolasis].
Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu
2013-04-01
To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P < 0.05). The A absolute value (A/CO) of Fg-ELISA was 1.70, which was also significantly higher than the value of Fh-ELISA (1.18) (P < 0.000 1). Fg-ELISA has a good detection effect and low cost, and is more suitable than Fh-ELISA and DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.
Analytical validation of a new point-of-care assay for serum amyloid A in horses.
Schwartz, D; Pusterla, N; Jacobsen, S; Christopher, M M
2018-01-17
Serum amyloid A (SAA) is a major acute phase protein in horses. A new point-of-care (POC) test for SAA (Stablelab) is available, but studies evaluating its analytical accuracy are lacking. To evaluate the analytical performance of the SAA POC test by 1) determining linearity and precision, 2) comparing results in whole blood with those in serum or plasma, and 3) comparing POC results with those obtained using a previously validated turbidimetric immunoassay (TIA). Assay validation. Analytical validation of the POC test was done in accordance with American Society of Veterinary Clinical Pathology guidelines using residual equine serum/plasma and whole blood samples from the Clinical Pathology Laboratory at the University of California-Davis. A TIA was used as the reference method. We also evaluated the effect of haematocrit (HCT). The POC test was linear for SAA concentrations of up to at least 1000 μg/mL (r = 0.991). Intra-assay CVs were 13, 18 and 15% at high (782 μg/mL), intermediate (116 μg/mL) and low (64 μg/mL) concentrations. Inter-assay (inter-batch) CVs were 45, 14 and 15% at high (1372 μg/mL), intermediate (140 μg/mL) and low (56 μg/mL) concentrations. SAA results in whole blood were significantly lower than those in serum/plasma (P = 0.0002), but were positively correlated (r = 0.908) and not affected by HCT (P = 0.261); proportional negative bias was observed in samples with SAA>500 μg/mL. The difference between methods exceeded the 95% confidence interval of the combined imprecision of both methods (15%). Analytical validation could not be performed in whole blood, the sample most likely to be used stall side. The POC test has acceptable accuracy and precision in equine serum/plasma with SAA concentrations of up to at least 1000 μg/mL. Low inter-batch precision at high concentrations may affect serial measurements, and the use of the same test batch and sample type (serum/plasma or whole blood) is recommended. Comparison of results between the POC test and the TIA is not recommended. © 2018 EVJ Ltd.
Mohammadpour, Niloofar; Saki, Jasem; Rafiei, Abdollah; Khodadadi, Ali; Tavalla, Mehdi; Cheraghian, Bahman
2016-10-01
Toxoplasma gondii is one of the most common causes of latent infections in humans worldwide. Detecting anti- Toxoplasma antibodies in serum using serological tests is a common method to diagnose toxoplasmosis. In the present study, an indigenous ELISA kit was prepared using tachyzoites from the RH strain of T. gondii , and its sensitivity and specificity were compared with those of commercial kits. To produce antigens, 0.02 mL of locally isolated T. gondii RH strain parasites along with 10 9 tachyzoites were injected into the peritoneal cavities of 50 laboratory mice (BALB/C). Parasites were collected after 4 days. After filtering and washing, the concentration of protein in sonicated tachyzoites was calculated using the Lowry protein assay. The dilution of antigen, serum and alkaline phosphatase conjugate was assessed in designing an indigenous ELISA method; then ELISA was performed based on these dilutions, and its sensitivity was determined using 200 serum samples. In addition, the specificity of the assay was evaluated using 40 serum samples from patients with tuberculosis, leukemia or hydatid cyst. Indigenous ELISA was used to examine 100 serum samples containing anti- T. gondii IgG, with a sensitivity of 98% (commercial kits: 100%). Another 100 serum samples containing anti- T. gondii IgM were also tested, with a sensitivity of 99% (commercial kits: 100%). When 40 serum samples from patients with leukemia, hydatid cyst or tuberculosis were examined using anti- T. gondii IgG, the specificity was 100%, identical to commercial kits. However, the specificity of a similar test with anti- T. gondii IgM was just 28.6% for serum samples from leukemia patients, 21.4% for hydatid cyst and 16.7% for tuberculosis. We found that purified locally isolated soluble crude antigens of the RH strain of T. gondii from the peritoneal cavity of mice may be one of the most promising antigens for detection of human toxoplasmosis in routine screening.
Can serums be replaced by Mueller-Hinton agar in germ tube test?
Atalay, M A; Koc, A N; Parkan, O M; Aydemir, G; Elmali, F; Sav, H
2017-01-01
The germ tube test (GTT) is inexpensive, easy, and well-defined test that differentiates Candida albicans (excluding Candida dubliniensis and Candida africana) from other species. The aim of this study was to evaluate various serums (i.e., human, rabbit, horse, and fetal bovine serum) used in the GTT and Mueller-Hinton agar (MHA). Fifty species isolated from various clinical samples that were defined as C. albicans by both conventional and DNA sequence analysis methods were included in the study. One to two colonies of C. albicans were mixed into 0.5-1 ml of fetal bovine serum, horse serum, rabbit serum, and human serum. Serums and MHA were incubated at 37°C for GTT. They were removed from the incubator and evaluated after 30 min, 1 h, 2 h, and 3 h of incubation. The GTT was accepted to be positive only if germ tube was 1/2 the width and 3 times the length of the parent yeast cell and with no constriction at the point of origin. When the use of serums and MHA for GTT was statistically evaluated, according to the positive scoring, the best results were obtained with MHA and with rabbit, horse, and fetal bovine serum, respectively. The best definition over time statistically was the third hour. It is suggested that inexpensive MHA is a fast, appropriate, and reliable medium for the probable diagnosis of GTT and C. albicans; however, additional studies are still needed to define other Candida species.
Evaluation of the Olympus AU-510 analyser.
Farré, C; Velasco, J; Ramón, F
1991-01-01
The selective multitest Olympus AU-510 analyser was evaluated according to the recommendations of the Comision de Instrumentacion de la Sociedad Española de Quimica Clinica and the European Committee for Clinical Laboratory Standards. The evaluation was carried out in two stages: an examination of the analytical units and then an evaluation in routine work conditions. The operational characteristics of the system were also studied.THE FIRST STAGE INCLUDED A PHOTOMETRIC STUDY: dependent on the absorbance, the inaccuracy varies between +0.5% to -0.6% at 405 nm and from -5.6% to 10.6% at 340 nm; the imprecision ranges between -0.22% and 0.56% at 405 nm and between 0.09% and 2.74% at 340 nm. Linearity was acceptable, apart from a very low absorbance for NADH at 340 nm; and the imprecision of the serum sample pipetter was satisfactory.TWELVE SERUM ANALYTES WERE STUDIED UNDER ROUTINE CONDITIONS: glucose, urea urate, cholesterol, triglycerides, total bilirubin, creatinine, phosphate, iron, aspartate aminotransferase, alanine aminotransferase and gamma-glutamyl transferase.The within-run imprecision (CV%) ranged from 0.67% for phosphate to 2.89% for iron and the between-run imprecision from 0.97% for total bilirubin to 7.06% for iron. There was no carryover in a study of the serum sample pipetter. Carry-over studies with the reagent and sample pipetters shows some cross contamination in the iron assay.
Depciuch, J; Parlinska-Wojtan, M
2018-02-20
Depression is a serious mental illness. To study the mechanism of depression and search for new, more effective therapies, animal models are often used. Unfortunately, none of the available models reflects all the symptoms of depression. Therefore researchers are looking for new tools to diagnose depression. Unfortunately, the nowadays-available depression diagnosis methods are only psychological tests. However, it is known, that the amount of phospholipids, proteins and lipids decreases during depression. Raman and FTIR (Fourier Transform Infra Red) spectroscopies provide information on the chemical compounds in the measured sample e.g. blood serum. These spectroscopic techniques may thus become reliable and accurate tools for evaluating changes in the amount of phospholipids and proteins in depression disease. In this study differences between dried and liquid blood serum samples of healthy and depressed individuals measured by Raman (range 0-3000cm -1 ) and FTIR (Fourier Transform Infrared) (range 900-3000cm -1 ) spectroscopy were evaluated. The resulting spectra and accurate analysis led to the conclusion that an appropriate measurement of the background and the elimination of peaks from water had the greatest impact on the reliability of the results. Furthermore, after detailed studies of FTIR and Raman spectra of dried and liquid blood serum samples, including a complete analysis of peaks after Kramers-Kröning (KK) transformation, it was found that the sample preparation did not affect the results obtained by Raman spectroscopy. In FTIR measurements only a minimal effect on peak intensity was observed. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluation of microRNA Stability in Plasma and Serum from Healthy Dogs.
Enelund, Lars; Nielsen, Lise N; Cirera, Susanna
2017-01-01
Early and specific detection of cancer is of great importance for successful treatment of the disease. New biomarkers, such as microRNAs, could improve treatment efficiency and survival ratio. In human medicine, deregulation of microRNA profiles in circulation has shown great potential as a new type of biomarker for cancer diagnostics. There are, however, few studies of circulating microRNAs in dogs. Extracellular circulating microRNAs have shown a high level of stability in human blood and other body fluids. Nevertheless, there are still important issues to be solved before microRNAs can be applied routinely as a clinical tool, one of them being their stability over time in media commonly used for blood sampling. Evaluation of the stability of microRNA levels in plasma and serum from healthy dogs after storage at room temperature for different time points before being processed. The levels of four microRNAs (cfa-let-7a, cfa-miR-16, cfa-miR-23a and cfa-miR-26a) known to be stably expressed from other canine studies, have been measured by quantitative real-time PCR (qPCR). MicroRNA levels were found sufficiently stable for gene profiling in serum- and plasma stored at room temperature for 1 hour but not for samples stored at room temperature for 24 hours. Storage at room temperature of serum and plasma samples intended for microRNA profiling should be kept for a minimum period of time before proceeding with RNA isolation. For the four microRNAs investigated in the present study, we did not find significant differences in microRNA levels between serum and plasma samples from the same time point. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Greenacre, C B; Young, D W; Behrend, E N; Wilson, G H
2001-11-01
To validate a novel high-sensitivity radioimmunoassay (RIA) procedure developed to accurately measure the relatively low serum total thyroxine (T4) concentrations of birds and reptiles and to establish initial reference ranges forT4 concentration in selected species of psittacine birds and snakes. 56 healthy nonmolting adult psittacine birds representing 6 species and 42 captive snakes representing 4 species. A solid-phase RIA designed to measure free T4 concentrations in dialysates of human serum samples was used without dialysis to evaluate total T4 concentration in treated samples obtained from birds and reptiles. Serum T4 binding components were removed to allow assay of undialyzed samples. Assay validation was assessed by determining recovery of expected amounts of T4 in treated samples that were serially diluted or to which T4 was added. Intra- and interassay coefficient of variation (CV) was determined. Mean recovery of T4 added at 4 concentrations ranged from 84.9 to 115.0% and 95.8 to 119.4% in snakes and birds, respectively. Intra- and interassay CV was 3.8 and 11.3%, respectively. Serum total T4 concentrations for 5 species of birds ranged from 2.02 to 768 nmol/L but ranged from 3.17 to 142 nmol/L for blue-fronted Amazon parrots; concentrations ranged from 0.21 to 6.06 nmol/L for the 4 species of snakes. This new RIA method provides a commercially available, accurate, and sensitive method for measurement of the relatively low serum T4 concentrations of birds and snakes. Initial ranges for the species evaluated were established.
Parathyroid hormone related protein concentration in human serum and CSF correlates with age.
Kushnir, Mark M; Peterson, Lisa K; Strathmann, Frederick G
2018-02-01
Parathyroid Hormone-Related Protein (PTHrP) is involved in intracellular calcium (Ca) regulation, and has been demonstrated to participate in regulation of Ca in brain cells, activation of neurons, and modulation of pain. However, there are conflicting reports regarding the presence of PTHrP in CSF. PTHrP and Ca were quantified in paired CSF and serum samples using mass spectrometry-based methods. Associations between PTHrP and Ca concentrations with age, sex and concentrations of nine CSF diagnostic markers in a set of 140 paired serum and CSF patient samples were evaluated. The observed median PTHrP concentration in CSF was 51 times higher than in serum; the median concentration of Ca in CSF was 1.8 times lower than in serum. We observed positive correlation between concentrations of PTHrP in CSF and serum (p=0.013). Distribution of PTHrP concentrations in serum was associated with age (p=0.0068) and the concentrations were higher in women. In samples with serum calcium concentrations within the reference intervals (n=118), central 95% distribution of concentrations for Ca-CSF, PTHrP-serum and PTHrP-CSF were 5.4 (4.5-6.1) mg/dL, 1.2 (0.5-2.5) pmol/L, 62 (22-125) pmol/L, respectively. Our data demonstrate that PTHrP is a normal constituent of human CSF with median concentrations 51 fold higher than in serum. Elevated serum PTHrP concentrations were positively correlated with age and significantly higher in women. Our data suggest that CSF could be a significant source of circulating PTHrP. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Juan, Cristina; Manyes, Lara; Font, Guillermina; Juan-García, Ana
2014-09-01
Study of dietary supplementation with ENN A mycotoxin during 28 days of exposure time on Wistar rats to determinate its levels in serum, urine and feces and, to evaluate the immunologic effect in peripheral blood lymphocytes (PBL) is presented. The first method for ENN A extraction, determination and detection by LC-MS/MS in serum, urine and feces samples is reported. ENN A food dose administrated was detected in serum samples and influenced lymphocyte phenotyping. Levels in serum were founded from the second week of the experiment; reaching values of 4.76 μg/ml on the fourth week, which corresponds to 3.24 μg/ml in blood. PBL as T helper (CD4(+)) were presented in greater percentages compared to control (p ≤ 0.001), while T cytotoxic (CD8(+)) decreased significantly compared to control (p ≤ 0.001). ENN A treatment significantly increased CD4(+)/CD3(+) and CD4(+)/CD8(+) ratios but significantly decreased CD8(+)/CD3(+) ratio. CD4(+)/CD8(+) ratio was 2.94:1, indicating that PBL surface antigen expression and immune status in Wistar rats treated were impaired by the ENN A mycotoxin. Copyright © 2014 Elsevier Ltd. All rights reserved.
2004-01-01
Abstract A study was performed to evaluate the presence of porcine reproductive and respiratory syndrome virus (PRRSV) in pig meat collected at slaughterhouses and its potential transmission to pigs via pig meat. A total of 1039 blood samples were collected from pigs upon their arrival at the abattoir. The following day, meat samples (n = 1027) were collected from the carcasses of these same pigs. Samples originated from 2 Canadian slaughterhouses, 1 situated in the province of Quebec and the other situated in the province of Manitoba. Serum samples were tested for antibodies to PRRSV and both serum and meat samples were also tested for PRRSV nucleic acid by polymerase chain reaction (PCR). Seropositivity to PRRSV for all serum samples was 74.3%. Furthermore 45 (4.3%) of the total serum samples and 19 (1.9%) of the 1027 meat samples were positive for PRRSV by PCR. Sequence analysis of open reading frame (ORF) 5 performed on 15 of the 19 PRRSV strains identified in pig meat indicated that 9 were field strains and 6 were vaccine-like (98% to 99.7% nucleotide homology with the Ingelvac RespPRRS/Repro vaccine). One of these 6 strains presented an intermediate 2-6-2 restriction fragment length polymorphism (RFLP) cut pattern and the others showed the characteristic 2-5-2 RFLP pattern of the vaccine strain. All strains sequenced were determined to be North American strains. In only 1 of the 19 PRRSV-positive meat samples could PRRSV be isolated. To test the potential infectivity of meat samples containing residual PRRSV, 11 of the PCR-positive meat samples (weighing 1.05 to 1.8 kg) were each used in feeding experiments of 2 PRRSV antibody-negative specific pathogen-free pigs of 9 wk of age. Samples were cut into several pieces and fed to each pair of pigs on 2 consecutive days. Each pig pair was housed in a separate cubicle and serum samples were collected at –7, 0, 7, 14, and 20 to 21 days post exposure. Seven pig pairs were found to be infected by PRRSV following ingestion of meat samples, including meat samples containing vaccine-like virus, as judged by the demonstration of PRRSV antibodies and/or PRRSV nucleic acid in the serum. In summary, the present study indicated that low residual quantities of PRRSV may be found in a small percentage of pig meat collected at slaugtherhouses. Furthermore, when this meat was fed raw to pigs in the experimental setting designed, pigs could be infected by PRRSV. PMID:15581220
TOISHI, Yuko; TSUNODA, Nobuo; NAGATA, Shun-ichi; KIRISAWA, Rikio; NAGAOKA, Kentaro; WATANABE, Gen; YANAGAWA, Yojiro; KATAGIRI, Seiji; TAYA, Kazuyoshi
2017-01-01
Testosterone (T) concentration is a useful indicator of reproductive function in male animals. However, T concentration is not usually measured in veterinary clinics, partly due to the unavailability of reliable and rapid assays for animal samples. In this study, a rapid chemiluminescent enzyme immunoassay system (CLEIA system) that was developed for the measurement of T concentration in humans use was validated for stallion blood samples. First, serum T concentrations were measured using the CLEIA system and compared with those measured by a fluoroimmunoassay that has been validated for use in stallions. The serum T concentrations measured by the two methods were highly correlated (r = 0.9865, n = 56). Second, to validate the use of whole blood as assay samples, T concentrations in whole blood and in the serum were measured by the CLEIA system. T concentrations in both samples were highly correlated (r = 0.9665, n = 64). Finally, to evaluate the practical value of the CLEIA system in clinical settings, T concentrations were measured in three stallions with reproductive abnormalities after the administration of human chorionic gonadotropin (hCG). Two stallions with small or absent testes in the scrotum showed an increase in T production in response to hCG administration and one stallion with seminoma did not. In conclusion, the CLEIA system was found to be a rapid and reliable tool for measuring T concentrations in stallions and may improve reproductive management in clinical settings and in breeding studs. PMID:29129877
Isolation of Coxiella burnetii from serum of patients with acute Q fever.
Vincent, Gemma A; Graves, Stephen R; Robson, Jennifer M; Nguyen, Chelsea; Hussain-Yusuf, Hazizul; Islam, Aminul; Fenwick, Stanley G; Stenos, John
2015-12-01
Worldwide there are few isolate collections of the intracellular bacterium Coxiella burnetii, due to the difficulties associated with working with the organism and the scarcity of suitable samples from which to attempt isolation. Particularly lacking are isolates from acute Q fever patients. The aim of this study was to evaluate whether the serum samples taken from patients with confirmed acute Q fever during the early stage of their disease represented a potential source of viable C. burnetii. Isolation was attempted from 65 of these samples by inoculation of the serum into Vero cell culture and was successful in 36 cases (55%). This high success rate was likely due to extended incubation of up to twelve weeks of the inoculated cultures, allowing the growth of the organism to levels detectable by PCR. Retrospective analysis of the time the sera was stored prior to inoculation into culture demonstrated that C. burnetii remained viable for 224 days in samples stored refrigerated and 371 days in samples stored frozen at -20 °C. These results demonstrate that standard serum samples taken from acute Q fever patients are a valuable source of new isolates of C. burnetii, with no special handling of the specimens required to maintain the organism's viability. Copyright © 2015 Elsevier B.V. All rights reserved.
Protein microarray analysis reveals BAFF-binding autoantibodies in systemic lupus erythematosus
Price, Jordan V.; Haddon, David J.; Kemmer, Dodge; Delepine, Guillaume; Mandelbaum, Gil; Jarrell, Justin A.; Gupta, Rohit; Balboni, Imelda; Chakravarty, Eliza F.; Sokolove, Jeremy; Shum, Anthony K.; Anderson, Mark S.; Cheng, Mickie H.; Robinson, William H.; Browne, Sarah K.; Holland, Steven M.; Baechler, Emily C.; Utz, Paul J.
2013-01-01
Autoantibodies against cytokines, chemokines, and growth factors inhibit normal immunity and are implicated in inflammatory autoimmune disease and diseases of immune deficiency. In an effort to evaluate serum from autoimmune and immunodeficient patients for Abs against cytokines, chemokines, and growth factors in a high-throughput and unbiased manner, we constructed a multiplex protein microarray for detection of serum factor–binding Abs and used the microarray to detect autoantibody targets in SLE. We designed a nitrocellulose-surface microarray containing human cytokines, chemokines, and other circulating proteins and demonstrated that the array permitted specific detection of serum factor–binding probes. We used the arrays to detect previously described autoantibodies against cytokines in samples from individuals with autoimmune polyendocrine syndrome type 1 and chronic mycobacterial infection. Serum profiling from individuals with SLE revealed that among several targets, elevated IgG autoantibody reactivity to B cell–activating factor (BAFF) was associated with SLE compared with control samples. BAFF reactivity correlated with the severity of disease-associated features, including IFN-α–driven SLE pathology. Our results showed that serum factor protein microarrays facilitate detection of autoantibody reactivity to serum factors in human samples and that BAFF-reactive autoantibodies may be associated with an elevated inflammatory disease state within the spectrum of SLE. PMID:24270423
Gümüş, Pınar; Nizam, Nejat; Nalbantsoy, Ayşe; Özçaka, Özgün; Buduneli, Nurcan
This cross-sectional study aims to evaluate saliva, serum levels of interleukin-21 (IL-21), IL-33, and prostaglandin E2 (PGE2) in patients with generalised chronic periodontitis or aggressive periodontitis. Before initiation of any periodontal treatment, saliva and serum samples were collected and clinical periodontal measurements were recorded from 94 participants (25 aggressive periodontitis patients, 25 chronic periodontitis patients, 44 periodontally healthy individuals). IL-21, IL-33 and PGE2 levels in serum and saliva samples were determined by ELISA. Data were tested statistically using Kruskal-Wallis, Mann-Whitney U-, and Spearman-rho rank tests. Saliva IL-33 levels were statistically significantly higher in the chronic than the aggressive group (p < 0.05). Serum IL-33, saliva and serum IL-21 and PGE2 levels were similar in the two periodontitis groups. Saliva IL-33 levels correlated with age in the chronic periodontitis group (p < 0.05). Statistically significant positive correlations were found between serum, saliva PGE2 levels and plaque index (p < 0.05). IL-33 and IL-21 levels in serum samples positively correlated in the periodontitis groups (p < 0.05). IL-21 and PGE2 analysis did not exhibit discriminating data between generalised chronic and aggressive periodontitis, but the present findings support the role of these cytokines in periodontitis. Statistically significantly higher saliva IL-33 levels in the chronic periodontitis group warrant further research.
Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Sun, Xuefei; Gao, Yuqian
2013-07-05
We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50-100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion and the multiplexing potential of this technique. Limits of quantification (LOQs) at low ng/mL levels with a medianmore » CV of ~12% were achieved for proteins spiked into human female serum using as little as 2 µL serum. PRISM-SRM provided up to ~1000-fold improvement in the LOQ when compared to conventional SRM measurements. Multiplexing capability of PRISM-SRM was also evaluated by two sets of serum samples with 6 and 21 target peptides spiked at the low attomole/µL levels. The results from SRM measurements for pooled or post-concatenated samples were comparable to those obtained from individual peptide fractions in terms of signal-to-noise ratios and SRM peak area ratios of light to heavy peptides. PRISM-SRM was applied to measure several ng/mL-level endogenous plasma proteins, including prostate-specific antigen, in clinical patient sera where correlation coefficients > 0.99 were observed between the results from PRISM-SRM and ELISA assays. Our results demonstrate that PRISM-SRM can be successfully used for quantification of low-abundance endogenous proteins in highly complex samples. Moderate throughput (50 samples/week) can be achieved by applying the post-concatenation or fraction multiplexing strategies. We anticipate broad applications for targeted PRISM-SRM quantification of low-abundance cellular proteins in systems biology studies as well as candidate biomarkers in biofluids.« less
Colon Reference Set Application: Mary Disis - University of Washington (2008) — EDRN Public Portal
The proposed study aims to validate the diagnostic value of a panel of serum antibodies for the early detection of colorectal cancer (CRC). We have developed a serum antibody based assay that shows promise in discriminating sera from CRC patients from healthy donors. We have evaluated two separate sample sets of sera that were available either commercially or were comprised of left over samples from previous studies by our group. Both sample sets showed concordance in discriminatory power. We have not been able to identify investigators with a larger, well defined sample set of early stage colon cancer sera and request assistance from the EDRN in obtaining such samples to help assess the potential diagnostic value of our autoantibody panel
Hollmen, T.; Franson, J.C.; Hario, Martti; Sankari, S.; Kilpi, Mikael; Lindstrom, K.
2001-01-01
During 1997–1999, we collected serum samples from 156 common eider (Somateria mollissima) females incubating eggs in the Finnish archipelago of the Baltic Sea. We used serum chemistry profiles to evaluate metabolic changes in eiders during incubation and to compare the health and nutritional status of birds nesting at a breeding area where the eider population has declined by over 50% during the past decade, with birds nesting at two areas with stable populations. Several changes in serum chemistries were observed during incubation, including (1) decreases in serum glucose, total protein, albumin, β‐globulin, and γ‐globulin concentrations and (2) increases in serum uric acid, creatine kinase, and β‐hydroxybutyrate concentrations. However, these changes were not consistent throughout the 3‐yr period, suggesting differences among years in the rate of carbohydrate, lipid, and protein utilization during incubation. The mean serum concentrations of free fatty acids, glycerol, and albumin were lowest and the serum α‐ and γ‐globulin levels were highest in the area where the eider population has declined, suggesting a role for nutrition and diseases in the population dynamics of Baltic eiders.
Hansen, Jessica; Slechta, E. Susan; Gates-Hollingsworth, Marcellene A.; Neary, Brandon; Barker, Adam P.; Bauman, Sean; Kozel, Thomas R.
2013-01-01
Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results. PMID:23114703
Hansen, Jessica; Slechta, E Susan; Gates-Hollingsworth, Marcellene A; Neary, Brandon; Barker, Adam P; Bauman, Sean; Kozel, Thomas R; Hanson, Kimberly E
2013-01-01
Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results.
The effect of short duration transportation on serum cortisol response in alpacas (Llama pacos).
Anderson, D E; Grubb, T; Silveira, F
1999-03-01
This research project evaluated the changes in serum cortisol in six male and six female alpacas in response to transportation of short duration. All alpacas were subjected to trailer transportation for 30 min. Serum samples were obtained prior to transportation, immediately after transportation, and after a 4-h recovery period. Heart rate was recorded at each time interval and observations of individual behavioural characteristics were recorded. Data were analysed using analysis of variance. Heart rate was not significantly changed by transportation stress. Serum cortisol concentration was significantly higher after transportation, but head returned to baseline concentration after the 4-h recovery period. Behavioural characteristics were not associated with changes in serum cortisol concentration.
Goyal, S.M.; Mech, L.D.; Rademacher, R.A.; Khan, M.A.; Seal, U.S.
1986-01-01
Serum samples (n = 137) from 47 wild wolves (Canis lupus; 21 pups and 26 adults) were evaluated from 1975 to 1985 for antibodies against canine parvovirus, using the hemagglutination inhibition (HI) test. In addition, several blood samples (n = 35) from 14 of these wolves (6 pups and 8 adults) were evaluated simultaneously for erythrocyte and leukocyte counts, and for hemoglobin and blood urea nitrogen concentrations. Sixty-nine (50%) of the serum samples (35 wolves) had HI titers of greater than or equal to 256, whereas 68 (50%) of the samples (16 wolves) had HI titers of less than or equal to 128. Significant differences in the geometric mean titers were not found between pups and adults or between males and females. Of the 47 wolves evaluated, 12 (25%) developed a greater than or equal to fourfold increase in antibody titers during the 11-year period, with 2 wolves developing serologic conversions in 1976. The data indicate that canine parvovirus may have begun infecting wolves before or at the same time that it began infecting the dog population in the United States.
Serum alkylresorcinols as biomarkers of dietary gluten exposure in coeliac disease.
Choung, R S; Murray, J A; Marietta, E V; Van Dyke, C T; Ross, A B
2017-03-01
Therapy for coeliac disease (CD) mainly relies on following a gluten-free diet (GFD); however, a serum marker for gluten intake has yet to be established. To evaluate the utility of alkylresorcinol concentrations for detecting gluten intake in studies of human and mouse. Alkylresorcinol concentrations were compared among treated patients with coeliac disease (n = 34), untreated coeliac disease patients (n = 36) and controls (n = 33). Furthermore, seven additional coeliac disease patients whose serum samples were available at diagnosis and after GFD were evaluated. In mice studies, alkylresorcinol concentrations were compared in the serum of five mice fed a regular chow and 10 mice fed lifelong with a gluten-free chow. In addition, the effect of adding gluten on changes of alkylresorcinol concentrations was also evaluated. Total alkylresorcinol concentrations were significantly lower in treated with coeliac disease [median (IQR), 3 (2-8) nmol/L], compared to untreated patients [median (IQR), 32 (11-74) nmol/L; P < 0.0001] or healthy controls [median (IQR), 54 (23-112) nmol/L; P < 0.0001]. Moreover, alkylresorcinol concentrations in coeliac disease patients significantly decreased after introduction of a GFD (median, 34 nmol/L at diagnosis vs. 5 nmol/L after GFD, P = 0.02). In the mice, median (IQR) total alkylresorcinol concentrations in serum samples of mice fed lifelong with a gluten-free chow was 1.8 (1.6-2.3) nmol/L, which was further significantly increased to 16 (11-22) nmol/L after 8 days of feeding with the gluten-free chow that had gluten added to it. (P = 0.008). Serum alkylresorcinol concentrations could be a useful marker for dietary gluten in coeliac disease. © 2017 John Wiley & Sons Ltd.
Steiner, J M; Rehfeld, J F; Pantchev, N
2010-01-01
An assay for the measurement of pancreatic elastase in dog feces has been introduced. The goal of this study was to evaluate the rate of false-positive fecal-elastase test results in dogs with suspected exocrine pancreatic insufficiency (EPI) and to assess serum cholecystokinin (CCK) concentrations in dogs with a false positive fecal elastase test result. Twenty-six fecal and serum samples from dogs suspected of EPI, for which samples had been submitted to a commercial laboratory (Vet Med Labor) for analysis. Prospective study. Serum trypsin-like immunoreactivity (TLI) was measured in 26 dogs with a decreased fecal elastase concentration of <10 microg/g feces. Serum CCK concentrations were measured in 21 of these dogs. Of 26 dogs with a decreased fecal elastase concentration, 6 (23%) had serum TLI concentrations within or above the reference range. Serum CCK concentrations were significantly higher in dogs with a true positive fecal elastase test result (median: 1.1 pmol/L; range: 0.1-3.3 pmol/L) than in those with a false positive fecal elastase test result (median: 0.1 pmol/L; range: 0.1-0.9 pmol/L; P value = .0163). The rate of false positive fecal elastase test results was high in this group of dogs, suggesting that diagnosis of EPI must be confirmed by other means. The decreased CCK concentration in dogs with a false positive fecal elastase test result could suggest that false positive results are because of decreased stimulation of exocrine pancreatic function caused by other conditions.
Cho, Sung E; Kim, Sollip; Kim, Young D; Lee, Hyojung; Seo, Dong H; Song, Junghan; Um, Tae H; Cho, Chong R; Kim, Nam H; Hwang, Jong H
2017-09-01
Background We evaluated the performance of ultra-performance liquid chromatography-tandem mass spectrometry to measure serum 3-epi-25-hydroxyvitamin D 3 , 25-hydroxyvitamin D 3 and 25-hydroxyvitamin D 2 concentrations in 519 infant, paediatric and adolescent serum samples in Korea. Methods We used a Kinetex XB-C18 column and isocratic methanol/water (77.5/22.5, v/v) with 0.025% (v/v) high-performance liquid chromatography solvent additive flowing at 0.25 mL/min, yielding an 11 min/sample run time. A TQD triple quadrupole mass spectrometer in electrospray ionization positive ion mode with multiple reaction monitoring transition via an MSMS vitamin D kit was used to evaluate precision, carryover, ion suppression and linearity. Samples were prepared using the 4-phenyl-1,2,4-triazoline-3,5-dione derivatization method. Results Intra- and inter-run precisions were 1.23-13.28% and 1.02-10.08%, respectively. Group carryovers were -0.27% and 0.10%, respectively. There was no ion suppression. The calibration curve showed good linearity from calibrator Level 1 (11.75 nmol/L) to 6 (375 nmol/L) with R 2 > 0.9999. The 3-epi-25-hydroxyvitamin D 3 and 25-hydroxyvitamin D 3 peaks were clearly separated in the extracted ion chromatogram. Infant serum samples 3-epi-25-hydroxyvitamin D 3 concentrations were significantly higher than paediatric and adolescent concentrations. Conclusions The ultra-performance liquid chromatography-tandem mass spectrometry assay performed acceptably, clearly separating 3-epi-25-hydroxyvitamin D 3 from 25-hydroxyvitamin D 3 . High 3-epi-25-hydroxyvitamin D 3 concentrations were observed in infant but not in paediatric and adolescent serum samples.
Comparison of serum Concentration of Se, Pb, Mg, Cu, Zn, between MS patients and healthy controls
Alizadeh, Anahita; Mehrpour, Omid; Nikkhah, Karim; Bayat, Golnaz; Espandani, Mahsa; Golzari, Alireza; Jarahi, Lida; Foroughipour, Mohsen
2016-01-01
Introduction Multiple Sclerosis (MS) is defined as one of the inflammatory autoimmune disorders and is common. Its exact etiology is unclear. There are some evidences on the role of environmental factors in susceptible genetics. The aim of this study is to evaluate the possible role of Selenium, Zinc, Copper, Lead and Magnesium metals in Multiple Sclerosis patients. Methods In the present analytical cross-sectional study, 56 individuals including 26 patients and 30 healthy controls were enrolled in the evaluation. The serum level of Se, Zn, Cu, Pb were quantified in graphite furnace conditions and flame conditions by utilizing an atomic absorption Perkin Elmer spectrophotometer 3030. The serum levels of Mg were measured by auto analyzer 1500 BT. The mean level of minerals (Zn, Pb, Cu, Mg, Se) in serum samples were compared in both cases and controls. The mean level of minerals (Zn, Pb, Cu, Mg, Se) in serum samples were compared in both cases and controls by using independent-samples t-test for normal distribution and Mann-Whitney U test as a non-parametric test. All statistical analyses were carried out using SPSS 11.0. Results As well as the Zn, Cu, and Se, there was no significant difference between MS patients and healthy individuals in Pb concentrations (p-value = 0.11, 0.14, 0.32, 0.20 respectively) but the level of Mg was significantly different (p= 0.001). Conclusion All serum concentrations of Zn, Pb, Se, Cu in both groups were in normal ranges and there was no difference in MS patients compared with the healthy group who were matched in genetics. Blood level of Mg was significantly lower in MS patients. But it should be noted that even with the low level of serum magnesium in MS patients, this value is still in the normal range. PMID:27757186
Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio
2015-04-07
This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors derived from the sample preparation step.
Evaluation of serum lysyl oxidase as a blood test for colorectal cancer.
Ward, S T; Weston, C J; Hepburn, E; Damery, S; Hejmadi, R K; Morton, D G; Middleton, G; Ismail, T; Adams, D H
2014-06-01
Lysyl oxidase (LOX) expression is elevated in colorectal cancer (CRC) tissue and associated with disease progression. A blood test may form a more acceptable diagnostic test for CRC although LOX has not previously been measured in the serum. We therefore sought to determine the clinical usefulness of a serum LOX test for CRC in a symptomatic population. Adult patients referred to a hospital colorectal clinic with bowel symptoms completed a questionnaire and provided a blood sample for serum LOX measurement. Associations between presenting symptoms, serum LOX concentrations and outcomes of investigations were tested by univariate and multivariate analyses to determine if serum LOX was clinically useful in the prediction of CRC. LOX expression in CRC and adjacent colon biopsies was evaluated by ELISA and immunohistochemistry. Thirty-one cases of colorectal cancer and 16 high-risk polyps were identified from a total of 962 participants. There was no association between serum LOX concentration and the presence of CRC, high-risk polyps or cancers at any site. LOX expression was significantly increased in CRC tissue compared to adjacent colon. Despite overexpression of LOX in CRC tissue, elevated serum levels could not be demonstrated. Serum LOX measurement is therefore not a clinically useful test for CRC. Copyright © 2013 Elsevier Ltd. All rights reserved.
Schistosoma real-time PCR as diagnostic tool for international travellers and migrants.
Cnops, Lieselotte; Tannich, Egbert; Polman, Katja; Clerinx, Jan; Van Esbroeck, Marjan
2012-10-01
To evaluate the use of a genus-specific PCR that combines high sensitivity with the detection of different Schistosoma species for diagnosis in international travellers and migrants in comparison to standard microscopy. The genus-specific real-time PCR was developed to target the 28S ribosomal RNA gene of the major human Schistosoma species. It was validated for analytical specificity and reproducibility and demonstrated an analytical sensitivity of 0.2 eggs per gram of faeces. Its diagnostic performance was further evaluated on 152 faecal, 32 urine and 38 serum samples from patients presenting at the outpatient clinic of the Institute of Tropical Medicine in Antwerp (Belgium). We detected Schistosoma DNA in 76 faecal (50.0%) and five urine (15.6%) samples of which, respectively, nine and one were not detected by standard microscopy. Only two of the 38 serum samples of patients with confirmed schistosomiasis were positive with the presently developed PCR. Sequence analysis on positive faecal samples allowed identification of the Schistosoma species complex. The real-time PCR is highly sensitive and may offer added value in diagnosing imported schistosomiasis. The genus-specific PCR can detect all schistosome species that are infectious to humans and performs very well with faeces and urine, but not in serum. © 2012 Blackwell Publishing Ltd.
Bomfim, Maria Rosa Quaresma; Ko, Albert; Koury, Matilde Cota
2005-08-10
The recombinant leptospiral protein LipL32 was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLipL32 IgG ELISA). The microscopic agglutination test (MAT) of 150 serum samples from cattle suspected of leptospirosis showed that 125 (83.3%) samples had positive reciprocal agglutination titres, which ranged from 100 to 1600. The highest titres were observed for the serovars Hardjoprajitno and Bratislava. In the rLipL32 IgG ELISA, 83.3% of the samples were positive. The sensitivity of IgG ELISA for 125 bovine sera, which had MAT titres of greater than or equal to 100, was 100%. ELISA showed a specificity of 100% with 58 bovine sera, which were negative at a 1:50 dilution in the MAT for Leptospira interrogans serovars. When analytical specificity of the IgG ELISA was evaluted using 60 bovine serum samples from animals showing serum antibodies to other pathogens that cause abortion in cattle, such as Babesia sp., Anaplasma sp. and Brucella sp. and no cross-reaction was observed. The recombinant LipL32 IgG ELISA can be an alternative to the MAT for diagnosis of leptospiral infection in cattle.
Judd, W J; Barnes, B A; Steiner, E A; Oberman, H A; Averill, D B; Butch, S H
1986-01-01
Direct antiglobulin tests (DATs) using anti-IgG were performed on 65,049 blood samples from prospective transfusion recipients; 3570 tests (5.49%) were positive. Using criteria published previously (primarily excluding patients not transfused within the preceding 14 days), 778 samples from other than neonatal patients were selected for further evaluation. Eluates that did not react were obtained on 518 (66.6%) of these samples. Warm-reactive autoantibodies were apparent in 192 eluates, while 16 contained drug-related antibodies, anti-A or anti-B from prior transfusion with ABO mismatched blood components, or anti-D passively acquired from immune serum globulin. Fifty-two eluates contained alloantibodies; however, in only six of these cases did the corresponding serum lack unexpected alloantibodies, as determined by routine pretransfusion studies. Three additional weakly reactive clinically significant alloantibodies were detected solely through additional serum tests performed on DAT-positive samples. On the basis of these findings, the DAT had a low predictive value when used to detect the early manifestations of an immune response to recently transfused red cells. Elimination of the autocontrol from routine pretransfusion testing, therefore, carries minimal risk to patients yet will undoubtedly contribute to the containment of health care costs. Moreover, the risk is lower than that associated with the elimination of the antiglobulin crossmatch.
Protein electrophoresis in cranes with presumed insect bite.
Hartup, Barry K; Schroeder, Carrie A
2006-06-01
Serum protein electrophoresis (SPE) has emerged as a potentially valuable diagnostic tool in avian medicine; yet, there is limited information regarding SPE in cranes. Since 2000, 20 cases of unilateral periocular or facial soft tissue swelling, blepharitis, feather loss, and ocular or nasal discharge attributed to insect bite hypersensitivity were observed in cranes from a captive breeding center. SPE may be useful for evaluating these lesions. The aim of this study was to characterize the inflammatory response in cranes with hypersensitivity reactions using SPE. Serum samples from 7 cranes diagnosed with hypersensitivity reactions were submitted to a diagnostic laboratory for agarose gel electrophoresis. Results were compared to those in control serum samples obtained from the same cranes during routine physical examination, when they were clinically healthy. Total protein and a- and g-globulin concentrations were significantly increased and albumin/globulin ratios were significantly decreased in serum samples from cranes with hypersensitivity lesions compared with control samples. Using SPE, we documented changes in protein fraction concentrations in cranes with clinical signs of hypersensitivity. The increase in alpha- and gamma-globulin concentrations suggested inflammation and antigenic stimulation, consistent with a Type I hypersensitivity reaction.
Detection of a Serum Siderophore by LC-MS/MS as a Potential Biomarker of Invasive Aspergillosis
Carroll, Cassandra S.; Amankwa, Lawrence N.; Pinto, Linda J.; Fuller, Jeffrey D.; Moore, Margo M.
2016-01-01
Invasive aspergillosis (IA) is a life-threatening systemic mycosis caused primarily by Aspergillus fumigatus. Early diagnosis of IA is based, in part, on an immunoassay for circulating fungal cell wall carbohydrate, galactomannan (GM). However, a wide range of sensitivity and specificity rates have been reported for the GM test across various patient populations. To obtain iron in vivo, A. fumigatus secretes the siderophore, N,N',N"-triacetylfusarinine C (TAFC) and we hypothesize that TAFC may represent a possible biomarker for early detection of IA. We developed an ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for TAFC analysis from serum, and measured TAFC in serum samples collected from patients at risk for IA. The method showed lower and upper limits of quantitation (LOQ) of 5 ng/ml and 750 ng/ml, respectively, and complete TAFC recovery from spiked serum. As proof of concept, we evaluated 76 serum samples from 58 patients with suspected IA that were investigated for the presence of GM. Fourteen serum samples obtained from 11 patients diagnosed with probable or proven IA were also analyzed for the presence of TAFC. Control sera (n = 16) were analyzed to establish a TAFC cut-off value (≥6 ng/ml). Of the 36 GM-positive samples (≥0.5 GM index) from suspected IA patients, TAFC was considered positive in 25 (69%). TAFC was also found in 28 additional GM-negative samples. TAFC was detected in 4 of the 14 samples (28%) from patients with proven/probable aspergillosis. Log-transformed TAFC and GM values from patients with proven/probable IA, healthy individuals and SLE patients showed a significant correlation with a Pearson r value of 0.77. In summary, we have developed a method for the detection of TAFC in serum that revealed this fungal product in the sera of patients at risk for invasive aspergillosis. A prospective study is warranted to determine whether this method provides improved early detection of IA. PMID:26974544
McCudden, Christopher; Axel, Amy E; Slaets, Dominique; Dejoie, Thomas; Clemens, Pamela L; Frans, Sandy; Bald, Jaime; Plesner, Torben; Jacobs, Joannes F M; van de Donk, Niels W C J; Moreau, Philippe; Schecter, Jordan M; Ahmadi, Tahamtan; Sasser, A Kate
2016-06-01
Monoclonal antibodies are promising anti-myeloma treatments. As immunoglobulins, monoclonal antibodies have the potential to be identified by serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE). Therapeutic antibody interference with standard clinical SPE and IFE can confound the use of these tests for response assessment in clinical trials and disease monitoring. To discriminate between endogenous myeloma protein and daratumumab, a daratumumab-specific immunofixation electrophoresis reflex assay (DIRA) was developed using a mouse anti-daratumumab antibody. To evaluate whether anti-daratumumab bound to and shifted the migration pattern of daratumumab, it was spiked into daratumumab-containing serum and resolved by IFE/SPE. The presence (DIRA positive) or absence (DIRA negative) of residual M-protein in daratumumab-treated patient samples was evaluated using predetermined assessment criteria. DIRA was evaluated for specificity, limit of sensitivity, and reproducibility. In all of the tested samples, DIRA distinguished between daratumumab and residual M-protein in commercial serum samples spiked with daratumumab and in daratumumab-treated patient samples. The DIRA limit of sensitivity was 0.2 g/L daratumumab, using spiking experiments. Results from DIRA were reproducible over multiple days, operators, and assays. The anti-daratumumab antibody was highly specific for daratumumab and did not shift endogenous M-protein. As the treatment of myeloma evolves to incorporate novel monoclonal antibodies, additional solutions will be needed for clinical monitoring of patient responses to therapeutic regimens. In the interim, assays such as DIRA can inform clinical outcomes by distinguishing daratumumab from endogenous M-protein by IFE.
Onwuneme, C; Diya, B; Uduma, O; McCarthy, R A; Murphy, N; Kilbane, M T; McKenna, M J; Molloy, E J
2016-08-01
Although the role of vitamin D in the prevention of rickets has long been well established, controversies still exist on the ideal dose of vitamin D supplementation in infants. We assessed serum 25-hydroxyvitamin D (25OHD) status simultaneously in maternal and cord samples and the response to vitamin D3 supplementation in neonates. Serum 25OHD levels were evaluated from maternal, and umbilical cord samples from term normal pregnancies. Repeat 25OHD levels were assessed in neonates with 25OHD below 30 nmol/L following vitamin D3 200 IU daily after 6 weeks. Blood samples were taken including 57 cord samples and 16 follow-up neonatal samples. Maternal and cord serum 25OHD were 43 ± 21 and 29 ± 15 nmol/L, respectively. Infants with 25OHD < 30 nmol/L (19.8 ± 4.7 nmol/L) had a significant increase in serum 25OHD (63.3 ± 14.5 nmol/L) following vitamin D3 200 IU daily after 6 weeks. Healthy Irish infants born at term are at high risk of vitamin D deficiency, but vitamin D3 200 IU daily, rapidly corrects poor vitamin D status.
Johns, Jennifer L.; Moorhead, Kaitlin A.; Hu, Jing; Moorhead, Roberta C.
2018-01-01
Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended. PMID:29497614
Kawaguchi, Migaku; Takatsu, Akiko
2009-08-01
A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.
SELDI-TOF-MS proteomic profiling of serum, urine, and amniotic fluid in neural tube defects.
Liu, Zhenjiang; Yuan, Zhengwei; Zhao, Qun
2014-01-01
Neural tube defects (NTDs) are common birth defects, whose specific biomarkers are needed. The purpose of this pilot study is to determine whether protein profiling in NTD-mothers differ from normal controls using SELDI-TOF-MS. ProteinChip Biomarker System was used to evaluate 82 maternal serum samples, 78 urine samples and 76 amniotic fluid samples. The validity of classification tree was then challenged with a blind test set including another 20 NTD-mothers and 18 controls in serum samples, and another 19 NTD-mothers and 17 controls in urine samples, and another 20 NTD-mothers and 17 controls in amniotic fluid samples. Eight proteins detected in serum samples were up-regulated and four proteins were down-regulated in the NTD group. Four proteins detected in urine samples were up-regulated and one protein was down-regulated in the NTD group. Six proteins detected in amniotic fluid samples were up-regulated and one protein was down-regulated in the NTD group. The classification tree for serum samples separated NTDs from healthy individuals, achieving a sensitivity of 91% and a specificity of 97% in the training set, and achieving a sensitivity of 90% and a specificity of 97% and a positive predictive value of 95% in the test set. The classification tree for urine samples separated NTDs from controls, achieving a sensitivity of 95% and a specificity of 94% in the training set, and achieving a sensitivity of 89% and a specificity of 82% and a positive predictive value of 85% in the test set. The classification tree for amniotic fluid samples separated NTDs from controls, achieving a sensitivity of 93% and a specificity of 89% in the training set, and achieving a sensitivity of 90% and a specificity of 88% and a positive predictive value of 90% in the test set. These suggest that SELDI-TOF-MS is an additional method for NTDs pregnancies detection.
Elsohaby, Ibrahim; Burns, Jennifer J.; Riley, Christopher B.; McClure, J. Trenton
2017-01-01
This study aimed to evaluate the digital Brix and optical serum total protein (STP) refractometers for measuring concentrations of serum immunoglobulin G (IgG) in alpacas and compare them to IgG concentrations measured by the reference method of radial immunodiffusion (RID) assay. The appropriate cutoff point for Brix and STP refractometers and the transmission infrared (TIR) spectroscopy method was determined for low IgG concentrations (< 10 g/L). Serum samples were collected from alpacas (N = 169) and tested by both refractometers. The correlation between Brix % and STP was high [correlation coefficient (r) = 0.99]. However, the correlation coefficients between Brix % and STP with serum RID-IgG concentrations were only 0.56 and 0.55, respectively. Twenty-one (12.4%) of 169 alpaca serum samples had IgG concentrations of < 10 g/L. Using receiver operator characteristic curve (ROC) analysis, the optimal cutoff points for the TIR assay, digital Brix, and optical STP refractometers for assessing low IgG (RID < 10 g/L) were 13 g/L, 8.8%, and 50 g/L, respectively. The TIR assay showed higher sensitivity (Se = 95.2%) and specificity (Sp = 96.8%) than either the digital Brix (Se = 90.5% and Sp = 65.5%) or optical STP (Se = 81% and Sp = 73.7%) refractometers for assessing alpacas with low IgG. In conclusion, the Brix and STP refractometers lack accuracy in measuring alpaca IgG concentrations, but may be useful for screening animals for low serum IgG. However, the TIR assay with a cutoff point of 13 g/L was more appropriate for identifying low IgG than either refractometer. Another study that focuses on neonatal crias is recommended in order to evaluate the usefulness of these assays for field diagnosing of failure of transfer of passive immunity (FTPI). PMID:28725112
Elsohaby, Ibrahim; Burns, Jennifer J; Riley, Christopher B; McClure, J Trenton
2017-07-01
This study aimed to evaluate the digital Brix and optical serum total protein (STP) refractometers for measuring concentrations of serum immunoglobulin G (IgG) in alpacas and compare them to IgG concentrations measured by the reference method of radial immunodiffusion (RID) assay. The appropriate cutoff point for Brix and STP refractometers and the transmission infrared (TIR) spectroscopy method was determined for low IgG concentrations (< 10 g/L). Serum samples were collected from alpacas (N = 169) and tested by both refractometers. The correlation between Brix % and STP was high [correlation coefficient (r) = 0.99]. However, the correlation coefficients between Brix % and STP with serum RID-IgG concentrations were only 0.56 and 0.55, respectively. Twenty-one (12.4%) of 169 alpaca serum samples had IgG concentrations of < 10 g/L. Using receiver operator characteristic curve (ROC) analysis, the optimal cutoff points for the TIR assay, digital Brix, and optical STP refractometers for assessing low IgG (RID < 10 g/L) were 13 g/L, 8.8%, and 50 g/L, respectively. The TIR assay showed higher sensitivity (Se = 95.2%) and specificity (Sp = 96.8%) than either the digital Brix (Se = 90.5% and Sp = 65.5%) or optical STP (Se = 81% and Sp = 73.7%) refractometers for assessing alpacas with low IgG. In conclusion, the Brix and STP refractometers lack accuracy in measuring alpaca IgG concentrations, but may be useful for screening animals for low serum IgG. However, the TIR assay with a cutoff point of 13 g/L was more appropriate for identifying low IgG than either refractometer. Another study that focuses on neonatal crias is recommended in order to evaluate the usefulness of these assays for field diagnosing of failure of transfer of passive immunity (FTPI).
p16 promoter hypermethylation: A useful serum marker for early detection of gastric cancer
Abbaszadegan, Mohammad Reza; Moaven, Omeed; Sima, Hamid Reza; Ghafarzadegan, Kamran; A'rabi, Azadeh; Forghani, Mohammad Naser; Raziee, Hamid Reza; Mashhadinejad, Ali; Jafarzadeh, Mostafa; Esmaili-Shandiz, Ehsan; Dadkhah, Ezzat
2008-01-01
AIM: To determine p16 promoter hypermethylation in gastric tumoral tissue and serum samples, its impact on p16-protein expression, and correlation with clinical and histological features. METHODS: Samples were obtained from 52 histologically confirmed cases of gastric adenocarcinoma. Gastric tissue and serum of 50 age- and sex-matched individuals with normal gastroscopy and biopsy were obtained as control samples. Methylation-specific polymerase chain reaction (MSP) was used to evaluate methylation status of p16 promoter. p16-protein expression was analyzed by immunohistochemical staining on paraffin-embedded sections. RESULTS: Methylation was detected in 44.2% (23/52) of tumoral tissues. 60.9% of them were also methylated in serum, i.e., 26.9% of all patients (14/52). Methylation was not detected in tissue and sera of control samples. p16-protein expression was decreased in 61.5% of cases (32/52), and was significantly associated with promoter hypermethylation (P < 0.001). Methylation was significantly more frequent in higher pathological grades (P < 0.05). Methylation was not associated with other clinicopathological features and environmental factors including H pylori infection and smoking. CONCLUSION: p16 promoter hypermethylation is an important event in gastric carcinogenesis. It is the principle mechanism of p16 gene silencing. It is related to malignant tumor behavior. Detection of DNA methylation in serum may be a biomarker for early detection of gastric cancer. PMID:18395906
Evaluation of serum sialic acid, fucose levels and their ratio in oral squamous cell carcinoma.
Chinnannavar, Sangamesh Ningappa; Ashok, Lingappa; Vidya, Kodige Chandrashekhar; Setty, Sunil Mysore Kantharaja; Narasimha, Guru Eraiah; Garg, Ranjana
2015-01-01
Detection of cancer at the early stage is of utmost importance to decrease the morbidity and mortality of the disease. Apart from the conventional biopsy, minimally invasive methods like serum evaluation are used for screening large populations. Thus, this study aimed to estimate serum levels of sialic acid and fucose and their ratio in oral cancer patients and in healthy control group to evaluate their role in diagnosis. Serum samples were collected from 52 healthy controls (group I) and 52 squamous cell carcinoma patients (group II). Estimation of serum levels of sialic acid and fucose and their ratio was performed. This was correlated histopathologically with the grades of carcinoma. Statistical analysis was done by using analysis of variance (ANOVA) test and unpaired "t" test. Results showed that serum levels of sialic acid and fucose were significantly higher in oral cancer patients compared to normal healthy controls (P < 0.001). The sialic acid to fucose ratio was significantly lower in cancer patients than in normal controls (P < 0.01). However, comparison with histological grading, habits, gender, and age group did not show any significant result. The mean serum sialic acid and fucose levels showed an increasing trend from controls to malignant group and their corresponding ratio showed decreasing trend from controls to malignant group. The ratio of sialic acid to fucose can be a useful diagnostic aid for oral cancer patients.
Peterson, Jennifer L.; Buskirk, Steven J.; Heckman, Michael G.; Parker, Alexander S.; Diehl, Nancy N.; Tzou, Katherine S.; Paryani, Nitesh N.; Ko, Stephen J.; Daugherty, Larry C.; Vallow, Laura A.; Pisansky, Thomas M.
2013-01-01
Background. Previous reports have shown a positive association between serum calcium level and prostate cancer mortality. However, there is no data regarding whether higher serum calcium levels are associated with increased risk of biochemical recurrence (BCR) following salvage radiation therapy (SRT) for prostate cancer. Herein, we evaluate the association between pretreatment serum calcium levels and BCR in a cohort of men who underwent SRT. Methods. We evaluated 165 patients who underwent SRT at our institution. Median dose was 65.0 Gy (range: 54.0–72.4 Gy). We considered serum calcium as both a continuous variable and a 3-level categorical variable (low [≤9.0 mg/dL], moderate [>9.0 mg/dL and ≤9.35 mg/dL], and high [>9.35 mg/dL]) based on sample tertiles. Results. We observed no evidence of a linear association between serum calcium and BCR (relative risk (RR): 0.96, P = 0.76). Compared to men with low calcium, there was no significantly increased risk of BCR for men with moderate (RR: 0.94, P = 0.79) or high (RR: 1.08, P = 0.76) serum calcium levels. Adjustment for clinical, pathological, and SRT characteristics in multivariable analyses did not alter these findings. Conclusion. Our results provide evidence that pretreatment serum calcium is unlikely to be a useful tool in predicting BCR risk following SRT. PMID:23606986
Exposure of Piglets to Enteroviruses Investigated by an Immunoassay Based on the EV-G1 VP4 Peptide.
Benkahla, Mehdi A; Sane, Famara; Desailloud, Rachel; Hober, Didier
2016-01-01
The aim of this study was to investigate the exposure of piglets to enteroviruses-G (EV-G) through the presence of antibodies in their serum. Serum samples were obtained from the vena cava of 10 piglets at 9 weeks of age and again 39 days later (day 39). They were tested using an immunoassay based on the EV-G1 VP4 peptide, since VP4 is highly conserved among the four Enterovirus capsid proteins, and by using a seroneutralization assay. For each serum collected on day 39 the optical density was high compared to the value obtained in serum collected earlier (p = 0.002). However, the titers of anti-EV-G1 serum neutralizing activity were not different in paired samples (p > 0.999). The sequence alignment of the EV-G1 VP4 peptide, encompassing 50 amino acids, used in the immunoassay showed 88% homology with EV-G, suggesting that antibodies directed toward other EV-G than EV-G1 may be detected. An immunoassay based on EV-G1 VP4 can detect an increased level of EV-G antibodies in piglet serum samples. Further studies are needed to determine whether this immunoassay may be useful for diagnosis and/or epidemiological studies and to monitor EV-G infection in pigs to evaluate strategies aimed to prevent enterovirus infections. © 2016 S. Karger AG, Basel.
Virological Survey in free-ranging wildcats (Felis silvestris) and feral domestic cats in Portugal.
Duarte, A; Fernandes, M; Santos, N; Tavares, L
2012-08-17
To determine the presence of viral pathogens in natural areas a survey was conducted on an opportunistic sample of fifty eight wild (Felis silvestris silvestris) and feral cats (F. s. catus). The biological materials included serum, lung tissue extract and stool. Feline leukemia virus p27 antigen was detected in 13/50 serum/lung tissue extract samples (26%), canine distemper virus antibodies were detected in 2/26 serum/lung tissue extract samples (7.7%), feline coronavirus RNA was present in 6/29 stool samples (20.7%) and feline parvovirus DNA in 2/29 stool samples (6.9%). Canine distemper virus RNA was not detected. Feline immunodeficiency virus and feline coronavirus antibodies were not detected. Evidence of exposure to feline leukemia virus, canine distemper virus, feline coronavirus and feline parvovirus was found in wild and feral cats raising the importance of performing a comprehensive survey to correctly evaluate the potential threat of infectious diseases to endangered species, namely to the wildcat and to the Iberian lynx, which is meant to be reintroduced after 2012 in Portugal. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ehresman, David J.; Froehlich, John W.; Olsen, Geary W.
2007-02-15
Interest in human exposure to perfluorinated acids, including perfluorobutanesulfonate (PFBS), perfluorohexanesulfonate (PFHS), perfluorooctanesulfonate (PFOS), and perfluorooctanoate (PFOA) has led to their measurement in whole blood, plasma and serum. Comparison of measurements in these different blood-based matrices, however, has not been rigorously investigated to allow for across-matrix comparisons. This research evaluated concentrations of PFBS, PFHS, PFOS, and PFOA in whole blood collected in heparin (lithium) and ethylenediamine tetraacetic acid (EDTA), plasma samples collected in heparin and EDTA, and serum (from whole blood allowed to clot). Blood samples were collected from 18 voluntary participants employed at 3M Company. Solid phase extraction methodsmore » were used for all analytical sample preparations, and analyses were completed using high-pressure liquid chromatography/tandem mass spectrometry methods. Serum concentrations ranged from: limit of quantitation (LOQ, 5 ng/mL) to 25 ng/mL for PFBS; LOQ (5 ng/mL) to 75 ng/mL for PFHS; LOQ (5 ng/mL) to 880 ng/mL for PFOS; and LOQ (5 or 10 ng/mL) to 7320 ng/mL for PFOA. Values less than the LOQ were not included in the statistical analyses of the mean of the ratios of individual values for the matrices. PFBS was not quantifiable in most samples. Serum to plasma ratios for PFHS, PFOS, and PFOA were 1:1 and this ratio was independent of the level of concentrations measured. Serum or plasma to whole blood ratios, regardless of the anticoagulant used, approximated 2:1. The difference between plasma and serum and whole blood corresponded to volume displacement by red blood cells, suggesting that the fluorochemicals are not found intracellularly or attached to the red blood cells.« less
Jager, Alessandra V; Tonin, Fernando G; Baptista, Gabriela Z; Souto, Pollyana C M C; Oliveira, Carlos A F
2016-05-01
The aim of this study was to evaluate the human exposure of individuals from Pirassununga, Brazil, to dietary aflatoxins B1 (AFB1) and M1 (AFM1) by determination of serum AFB1-lysine and urinary aflatoxin biomarkers (AFM1 and AFB1-N(7)-guanine). The participants were recruited among employees from a Campus of the University of São Paulo, which provided food samples from their homes, as well as serum and urine samples four times every three months, from June 2011 until March 2012. The probable daily intake (PDI) of aflatoxin was estimated by using the results from analysis of food products collected by the time of samples collection, and data from a 24-hour dietary recall questionnaire. Analyses of AFB1 and AFM1 in food samples were conducted by high-performance liquid chromatography with fluorescence detection. Biomarkers in serum and urine were determined by tandem mass spectrometry. AFB1 and AFM1 were detected in 38 samples of cereals (28%, N=136) and 31 milk products (36%, N=86), respectively. AFB1-lysine and AFB1-N(7)-guanine and were not detected in serum or urine samples, respectively. However, AFM1 was found in 74 urine samples (65%), at mean levels in the 4 sampling times ranging from 0.37±0.23 to 1.70±2.88pg/mg creatinine. The mean PDI varied among different sampling times, ranging from 0.09±0.09 to 1.35±5.98ng/kg body weight/day. A modest though significant correlation (r=0.45; p=0.03; N=23) was found for the first time in Brazil between the AFM1 concentration in urine and the PDI for total aflatoxins (AFB1+AFM1) in sampling 1 (June 2011). Urinary AFM1 was confirmed as very sensitive for monitoring the human exposure to dietary aflatoxin. Further studies using serum and urinary biomarkers are needed to estimate the aflatoxin exposure of populations in higher risk areas in Brazil. Copyright © 2015 Elsevier GmbH. All rights reserved.
Oxidative stress, d-ROMs test, and ceruloplasmin.
Colombini, Francesco; Carratelli, Mauro; Alberti, Angelo
2016-01-01
Human serum samples were evaluated for oxidative stress with the d-ROMs test. The ceruloplasmin (CP) and copper contents of the samples was independently measured and compared to those calculated on the basis of the d-ROMs test results for pure CP solutions. The d-ROMs readings did not show any significant correlation with either the CP or copper contents of the samples. Critical interference of CP on the d-ROMs test was therefore excluded and the usefulness of the test in the evaluation of global oxidative status of a biological sample could be reassessed.
de Moraes, F M; Espósito, D L A; Klein, T M; da Fonseca, B A L
2018-01-01
Clinical manifestations of Zika, dengue, and chikungunya virus infections are very similar, making it difficult to reach a diagnosis based only on clinical grounds. In addition, there is an intense cross-reactivity between antibodies directed to Zika virus and other flaviviruses, and an accurate Zika diagnosis is best achieved by real-time RT-PCR. However, some real-time RT-PCR show better performance than others. To reach the best possible Zika diagnosis, the analytic sensitivity of some probe-based real-time RT-PCR amplifying Zika virus RNA was evaluated in spiked and clinical samples. We evaluated primers and probes to detect Zika virus, which had been published before, and tested sensitivity using serum spiked and patient samples by real-time RT-PCR. When tested against spiked samples, the previously described primers showed different sensitivity, with very similar results when samples from patients (serum and urine) were analyzed. Real-time RT-PCR designed to amplify Zika virus NS1 showed the best analytical sensitivity for all samples.
Assessment of serum HE4 levels throughout the normal menstrual cycle.
Moore, Richard G; Plante, Beth; Hartnett, Erin; Mitchel, Jessica; Raker, Christine A; Vitek, Wendy; Eklund, Elizabeth; Lambert-Messerlian, Geralyn
2017-07-01
Human epididymis protein 4 is a serum biomarker to aid in differentiating benign and malignant disease in women with a pelvic mass. Interpretation of human epididymis protein 4 results relies on robust normative data. The purpose of this study was to evaluate whether human epididymis protein 4 levels are variable in women during the normal menstrual cycle. Healthy women, 18-45 years old, with regular menstrual cycles were recruited from community gynecologic practices in Rhode Island. Women consented to enroll and to participate by the donation of blood and urine samples at 5 specific times over the course of each cycle. Levels of reproductive hormones and human epididymis protein 4 were determined. Data were analyzed with the use of linear regression after log transformation. Among 74 enrolled cycles, 53 women had confirmed ovulation during the menstrual cycle and completed all 5 sample collections. Levels of estradiol, progesterone, and luteinizing hormone displayed the expected menstrual cycle patterns. Levels of human epididymis protein 4 in serum were relatively stable across the menstrual cycle, except for a small ovulatory (median, 37.0 pM) increase. Levels of human epididymis protein 4 in urine, after correction for creatinine, displayed the same pattern of secretion observed in serum. Serum human epididymis protein 4 levels are relatively stable across the menstrual cycle of reproductive-aged women and can be determined on any day to evaluate risk of ovarian malignancy. A slight increase is expected at ovulation; but even with this higher human epididymis protein 4 level, results are well within the healthy reference range for women (<120 pM). Levels of human epididymis protein 4 in urine warrant further investigation for use in clinical practice as a simple and convenient sample. Copyright © 2017 Elsevier Inc. All rights reserved.
Stafylis, Chrysovalantis; Klausner, Jeffrey D
2017-01-01
Fourth generation assays detect simultaneously antibodies for HIV and the p24 antigen, identifying HIV infection earlier than previous generation tests. Previous studies have shown that the Alere Determine HIV-1/2 Combo has lower than anticipated performance in detecting antibodies for HIV and the p24 antigen. Furthermore, there are currently very few studies evaluating the performance of Standard Diagnostics BIOLINE HIV Ag/Ab Combo. To evaluate the performance of the Alere Determine HIV-1/2 Combo and the Standard Diagnostics BIOLINE HIV Ag/Ab Combo in a panel of frozen serum samples. The testing panel included 133 previously frozen serum specimens from the UCLA Clinical Microbiology & Immunoserology laboratory. Reference testing included testing for HIV antibodies by a 3rd generation enzyme immunoassay followed by HIV RNA detection. Antibody negative and RNA positive sera were also tested by a laboratory 4th generation HIV Ab/Ag enzyme immunoassay. Reference testing yielded 97 positives for HIV infection and 36 negative samples. Sensitivity of the Alere test was 95% (88-98%), while the SD Bioline sensitivity was 91% (83-96%). Both assays showed 100% (90-100%) specificity. No indeterminate or invalid results were recorded. Among 13 samples with acute infection (HIV RNA positive, HIV antibody negative), 12 were found positive by the first assay and 8 by the second. The antigen component of the Alere assay detected 10 acute samples, while the SD Bioline assay detected only one. Both rapid assays showed very good overall performance in detecting HIV infection in frozen serum samples, but further improvements are required to improve the performance in acute infection.
Hulejová, Hana; Kryštůfková, Olga; Mann, Heřman; Klein, Martin; Pavlíčková, Klára; Zámečník, Josef; Vencovský, Jiří; Šenolt, Ladislav
2016-01-01
The aim of this study was to evaluate serum levels of visfatin in anti-Jo-1-positive myositis patients, its expression in muscle tissue and to investigate potential relationships between visfatin, B-cell activating factor of the TNF family (BAFF), disease activity and anti-Jo-1 autoantibody levels. Serum levels of visfatin and BAFF were measured in 38 anti-Jo-1 positive myositis patients and 35 healthy subjects. Disease activity was evaluated by myositis disease activity assessment tool (MYOACT) using visual analogue scales (VAS) and by serum muscle enzymes. Visfatin expression was evaluated by immunohistochemistry in muscle tissue of myositis patients (n=10) and compared with non-inflammatory control muscle tissue samples from patients with myasthenia gravis (n=5). Serum visfatin and BAFF levels were significantly higher in myositis patients compared to healthy subjects and were associated with clinical muscle activity assessed by VAS. Only serum BAFF levels, but not visfatin levels, positively correlated with muscle enzyme concentrations and anti-Jo1 antibody levels. There was a positive correlation between visfatin and BAFF serum levels in myositis patients but a negative correlation was observed in healthy subjects. Visfatin expression was up-regulated in endomysial and perimysial inflammatory infiltrates of muscle tissue from myositis patients. Up-regulation of visfatin in myositis muscle tissue and an association between increased visfatin levels and muscle disease activity evaluated by MYOACT in anti-Jo-1 positive myositis patients could support possible role of visfatin in the pathogenesis of myositis.
Zeng, Jie; Qi, Tianqi; Wang, Shu; Zhang, Tianjiao; Zhou, Weiyan; Zhao, Haijian; Ma, Rong; Zhang, Jiangtao; Yan, Ying; Dong, Jun; Zhang, Chuanbao; Chen, Wenxiang
2018-04-25
The aim of the current study was to evaluate the commutability of commercial control materials and human serum pools and to investigate the suitability of the materials for the external quality assessment (EQA) of serum apolipoprotein A-I (apo A-I) measurement. The Clinical and Laboratory Standards Institute (CLSI) EP14-A3 protocol was used for the commutability study. Apo A-I concentrations in two levels of commercial control materials used in EQA program, two fresh-frozen human serum pools (FSPs) and two frozen human serum pools prepared from residual clinical specimens (RSPs) were measured along with 50 individual samples using nine commercial assays. Measurement results of the 50 individual samples obtained with different assays were pairwise analyzed by Deming regression, and 95% prediction intervals (PIs) were calculated. The commutability of the processed materials was evaluated by comparing the measurement results of the materials with the limits of the PIs. The FSP-1 was commutable for all the 36 assay pairs, and FSP-2 was commutable for 30 pairs; RSP-1 and RSP-2 showed commutability for 27/36 and 22/36 assay pairs, respectively, whereas the two EQA materials were commutable only for 4/36 and 5/36 assay pairs, respectively. Non-commutability of the tested EQA materials has been observed among current apo A-I assays. EQA programs need either to take into account the commutability-related biases in the interpretation of the EQA results or to use more commutable materials. Frozen human serum pools were commutable for most of the assays.
Schellenberg, François; Mennetrey, Louise; Girre, Catherine; Nalpas, Bertrand; Pagès, Jean Christophe
2008-01-01
In this study, we evaluated the new %CDT by the HPLC method (Bio-Rad, Germany) on a Varianttrade mark HPLC system (Bio-Rad), checked the correlation with well-known methods and calculated the diagnostic value of the test. Intra-run and day-to-day precision values were calculated for samples with extreme serum transferrin concentrations, high trisialotransferrin and interfering conditions (haemolysed, lactescent and icteric samples). The method was compared with two routine procedures, the %CDT TIA (Bio-Rad, Hercules, CA, USA) and the Capillarystrade mark CDT (Sebia, France). A total of 350 clinical sera samples were used for a case-control study. Precision values were better in high CDT and medium CDT pools than in low CDT pools. The serum transferrin concentration had no effect on CDT measurement, except in samples with serum transferrin <1 g/L. Haemolysis was the only interfering situation. The method showed high correlation (r(2) > 0.95) with the two other methods (%CDT TIA and CZE %CDT). The global predictive value of the test was >0.90 at 1.9% cut-off. These results demonstrate that the %CDT by the HPLC test is suitable for CDT routine measurement; the results from the high-throughput Varianttrade mark system are well correlated with other methods and are of high diagnostic value.
Detection of autoantibodies against thyroid peroxidase in serum samples of hypothyroid dogs.
Skopek, Evelyn; Patzl, Martina; Nachreiner, Raymond F
2006-05-01
To establish a sensitive test for the detection of autoantibodies against thyroid peroxidase (TPO) in canine serum samples. 365 serum samples from dogs with hypothyroidism as determined on the basis of serum concentrations of total and free triiodothyronine (T3), total and free thyroxine (T4), and thyroid-stimulating hormone, of which 195 (53%) had positive results for at least 1 of 3 thyroid autoantibodies (against thyroglobulin [Tg], T4, or T3) and serum samples from 28 healthy dogs (control samples). TPO was purified from canine thyroid glands by extraction with detergents, ultracentrifugation, and precipitation with ammonium sulfate. Screening for anti-TPO autoantibodies in canine sera was performed by use of an immunoblot assay. Thyroid extract containing TPO was separated electrophoretically, blotted, and probed with canine sera. Alkaline phosphatase-conjugated rabbit anti-dog IgG was used for detection of bound antibodies. TPO bands were observed at 110, 100, and 40 kd. Anti-TPO autoantibodies against the 40-kd fragment were detected in 33 (17%) sera of dogs with positive results for anti-Tg, anti-T4, or anti-T3 autoantibodies but not in sera of hypothyroid dogs without these autoantibodies or in sera of healthy dogs. The immunoblot assay was a sensitive and specific method for the detection of autoantibodies because it also provided information about the antigen. Anti-TPO autoantibodies were clearly detected in a fraction of hypothyroid dogs. The value of anti-TPO autoantibodies for use in early diagnosis of animals with thyroid gland diseases should be evaluated in additional studies.
Ximenes, Camila; Brandão, Eduardo; Oliveira, Paula; Rocha, Abraham; Rego, Tamisa; Medeiros, Rafael; Aguiar-Santos, Ana; Ferraz, João; Reis, Christian; Araujo, Paulo; Carvalho, Luiz; Melo, Fabio L
2014-12-01
The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.
Prevalence of hepatitis A viral RNA and antibodies among Chinese blood donors.
Sun, P; Su, N; Lin, F Z; Ma, L; Wang, H J; Rong, X; Dai, Y D; Li, J; Jian, Z W; Tang, L H; Xiao, W; Li, C Q
2015-12-09
Like other developing countries, China was reported to have a relatively high seroprevalence of anti-hepatitis A antibodies (anti-HAV). However, no studies have evaluated the prevalence of anti-HAV and HAV RNA among voluntary blood donors with or without elevated serum alanine transaminase (ALT) levels. Anti-HAV antibodies were detected using an enzyme-linked immunosorbent assay, and reverse transcription quantitative polymerase chain reaction was carried out for detection of HAV RNA. In the current study, we analyzed a total of 450 serum samples with elevated ALT levels (≥40 U/L) and 278 serum samples with non-elevated ALT levels. Seroprevalence rates of anti-HAV were 51.6% in donors with elevated ALT and 41.4% in donors with non-elevated ALT; however, none of the samples was positive for HAV RNA. The results of our study showed lower seroprevalence rates of anti-HAV in blood donors (irrespective of ALT levels) than those in published data on Chinese populations. Although donors with elevated ALT had statistically higher prevalence rates of anti- HAV than did those with non-elevated ALT, none of the serum samples had detectable levels of the active virus. In conclusion, our results demonstrate that the transmission of hepatitis A by blood transfusion will occur rarely.
Hines, Erin P.; Calafat, Antonia M.; Silva, Manori J.; Mendola, Pauline; Fenton, Suzanne E.
2009-01-01
Background Phthalates are ubiquitous in the environment, but concentrations in multiple media from breast-feeding U.S. women have not been evaluated. Objectives The objective of this study was to accurately measure and compare the concentrations of oxidative monoester phthalate metabolites in milk and surrogate fluids (serum, saliva, and urine) of 33 lactating North Carolina women. Methods We analyzed serum, saliva, urine, and milk for the oxidative phthalate metabolites mono(3-carboxypropyl) phthalate, mono(2-ethyl-5-carboxypentyl) phthalate (MECPP), mono(2-ethyl-5-hydroxyhexyl) phthalate, and mono(2-ethyl-5-oxohexyl) phthalate using isotope-dilution high-performance liquid chromatography tandem mass spectroscopy. Because only urine lacks esterases, we analyzed it for the hydrolytic phthalate monoesters. Results We detected phthalate metabolites in few milk (< 10%) and saliva samples. MECPP was detected in > 80% of serum samples, but other metabolites were less common (3–22%). Seven of the 10 urinary metabolites were detectable in ≥ 85% of samples. Monoethyl phthalate had the highest mean concentration in urine. Metabolite concentrations differed by body fluid (urine > serum > milk and saliva). Questionnaire data suggest that frequent nail polish use, immunoglobulin A, and fasting serum glucose and triglyceride levels were increased among women with higher concentrations of urinary and/or serum phthalate metabolites; motor vehicle age was inversely correlated with certain urinary phthalate concentrations. Conclusions Our data suggest that phthalate metabolites are most frequently detected in urine of lactating women and are less often detected in serum, milk, or saliva. Urinary phthalate concentrations reflect maternal exposure and do not represent the concentrations of oxidative metabolites in other body fluids, especially milk. PMID:19165392
Spencer, Kevin; Cuckle, Howard S
2002-10-01
To assess the within person biological variability of first trimester maternal serum biochemical markers of trisomy 21 across the 10-14 week gestational period. To evaluate whether repeat sampling and testing of free beta-hCG and PAPP-A during this period would result in an improved detection rate. Women presenting at the first trimester OSCAR clinic have blood collected prior to ultrasound dating and nuchal translucency measurement. All samples are analysed for free beta-hCG and PAPP-A before an accurate estimate of gestation is available. In 10% of cases the gestation is prior to the minimum time for NT measurement (11 weeks) and these women are rebooked for a repeat visit to the clinic at the appropriate time. Our fetal database was interrogated to obtain cases in which two maternal blood samples had been collected and analysed in the 10-14 week period. Using data from the marker correlations and statistical modelling, the impact of repeat testing on detection rate for trisomy 21 at a fixed 5% false positive rate, was assessed. 261 pairs of data were available for analysis collected over a 3 year period. The correlation between free beta-hCG in sample 1 and sample 2 was 0.890 and that for PAPP-A was 0.827. The average within person biological variation for free beta-hCG was 21% and 32% for PAPP-A. The increase in detection rate when using both sets of marker data was 3.5% when using serum biochemistry and maternal age, and 1.3% when using nuchal translucency, serum biochemistry and maternal age. Repeat sampling and testing of maternal serum biochemical markers is unlikely to substantially improve first trimester screening performance. Copyright 2002 John Wiley & Sons, Ltd.
Petrini, Stefano; Pierini, Ilaria; Giammarioli, Monica; Feliziani, Francesco; De Mia, Gian Mario
2017-03-01
We evaluated the use of oral fluid as an alternative to serum samples for Classical swine fever virus (CSFV) detection. Individual oral fluid and serum samples were collected at different times post-infection from pigs that were experimentally inoculated with CSFV Alfort 187 strain. We found no evidence of CSFV neutralizing antibodies in swine oral fluid samples under our experimental conditions. In contrast, real-time reverse transcription-polymerase chain reaction could detect CSFV nucleic acid from the oral fluid as early as 8 d postinfection, which also coincided with the time of initial detection in blood samples. The probability of CSFV detection in oral fluid was identical or even higher than in the corresponding blood sample. Our results support the feasibility of using this sampling method for CSFV genome detection, which may represent an additional cost-effective tool for CSF control.
Hayashi, Kuniki; Hoshino, Tadashi; Yanai, Mitsuru; Tsuchiya, Tatsuyuki; Kumasaka, Kazunari; Kawano, Kinya
2004-06-01
It is well known that serious method-related differences exist in results of serum CA19-9, and the necessity of standardization has been pointed out. In this study, differences of serum tumor marker CA19-9 levels obtained by various immunoassay kits (CLEIA, FEIA, LPIA and RIA) were evaluated in sixty-seven clinical samples and five calibrators and the possibility to improve the inter-methodological differences were observed not only for clinical samples but also for calibrators. We supposed an assumed standard material using by a calibrator. We calculated the serum levels of CA19-9 when using the assumed standard material for three different measurement methods. We approximate the CA19-9 values using by this method. It is suggested that the obtained CA19-9 values could be approximated by recalculation with the assumed standard material would be able to correct between-method and between-laboratory discrepancies in particular systematic errors.
NASA Astrophysics Data System (ADS)
Nixon, David E.; Neubauer, Kenneth R.; Eckdahl, Steven J.; Butz, John A.; Burritt, Mary F.
2002-05-01
A Dynamic Reaction Cell™ inductively coupled argon plasma mass spectrometer (DRC-ICP-MS) was evaluated for the determination of chromium and vanadium in serum and urine. Reaction cell conditions were evaluated for the elimination of ArC + and ClOH + interferences on chromium at mass 52 and OCl + on vanadium at mass 51. A diluent containing only 1% nitric acid and internal standards (Y and Ga) was used to prepare serum and urine for analysis. Instrument response calibration was achieved by using aqueous acidic standards spiked into pooled sera or urine matrices. The slopes of the calibration curves prepared in urine and serum matrices were nearly identical. On average, chromium detection limits are 2.5 times lower using the DRC than Zeeman graphite furnace atomic absorption spectrometry (ZGFAAS). Vanadium detection limits are approximately 50 times lower. Average detection limits achieved with DRC-ICP-MS are 0.075 μg Cr/l and 0.028 μg V/l. Average results for the analysis of National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1598 Bovine Serum (attained over 22 days) are: 0.14 μg Cr/l and 0.068 μg V/l. The reference concentrations for vanadium and chromium in NIST SRM 1598 are (0.06) μg V/l and 0.14±0.08 μg Cr/l, respectively. Results for chromium and vanadium determinations on ICP-MS survey samples from the Toxocologie du Quebec are equivalent to those reported by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for the same survey samples.
Gholizadeh, Narges; Khoini Poorfar, Hossein; TaghaviZenouz, Ali; Vatandoost, Masoumeh; Mehdipour, Masoumeh
2015-01-01
Lichen planus is a mucocutaneous disease which is relatively common and in 30-70% of patients, mucosal lesions can be seen and known as a precancerous lesion but its etiology is not completely understood. Desmogleins I and III are the main desmosomal transmembrane proteins. These proteins have been identified as the autoantigen of the autoimmune disease. The aim of this study was evaluation of serum autoantibodies against desmogleins Ι, ΙΙΙ in oral lichen planus . We attempted to determine the etiology of this disease with evaluation of these serum factors. Thirty-five patients with oral lichen planus and 35 healthy controls were recruited and tested for serum autoantibodies against desmogleins Ι, ΙΙΙ and indirect immunofluorescence also performed. Data were analyzed by statistical-analytical methods (Independent sample t -test) with using the SPSS.15 software. Serum autoantibody against desmoglein Ι had no significant difference in the two groups ( P =0.31 ) but significant increase in serum autoantibody to desmoglein ΙΙΙ was found in patients with oral lichen planus ( P =0.00) . It seems that autoantibody against desmoglein III has a significant role in the pathogenesis of oral lichen planus.
Transfer of perfluoroalkyl substances from mother to fetus in a Spanish birth cohort.
Manzano-Salgado, Cyntia B; Casas, Maribel; Lopez-Espinosa, Maria-Jose; Ballester, Ferran; Basterrechea, Mikel; Grimalt, Joan O; Jiménez, Ana-María; Kraus, Thomas; Schettgen, Thomas; Sunyer, Jordi; Vrijheid, Martine
2015-10-01
Prenatal exposure to perfluoroalkyl substances (PFAS) might affect child health; thus estimating PFAS fetal burden is relevant. PFAS fetal burden is best estimated in cord samples; previous studies have used either maternal plasma or serum during pregnancy as proxy, but their validity is not clear. We aimed to evaluate PFAS transfer between mother and fetus and determine its predictors in a Spanish birth cohort. We measured perfluorobutane sulfonate (PFBS), perfluorohexane sulfonate (PFHxS), perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and perfluorononanoate (PFNA) in maternal blood and cord serum from 66 mother-child pairs. We used Spearman's rank coefficients to correlate PFAS concentrations in first trimester maternal plasma and serum, with cord serum samples. We assessed PFAS placental transfer by calculating maternal to cord ratios and examined their association with maternal socio-demographic characteristics and child sex using linear regression models. Median concentrations of PFAS (ng/mL) of PFHxS, PFOS, PFOA, and PFNA in maternal plasma (0.79, 6.18, 2.85 and 0.84, respectively) and serum (0.84, 6.99, 2.97 and 0.85) were higher than in cord serum (0.40, 1.86, 1.90 and 0.32). PFBS was not detected. Positive Spearman's correlations (p-values<0.001) were found between maternal plasma and serum (⍴≥0.80), maternal plasma and cord (⍴≥0.66), and maternal serum and cord samples (⍴≥0.67). Maternal plasma to cord ratios were above 1 (PFHxS: 2.35 [95%CI: 2.05, 2.70], PFOS: 3.33 [3.05, 3.62], PFOA: 1.37 [1.27, 1.48], PFNA: 2.39 [2.18, 2.63]); maternal serum to cord ratios were similar. Maternal to cord ratios decreased with maternal age, but not with other socio-demographic factors. Our results suggest that PFAS fetal body burden can be assessed using as proxy maternal plasma or serum collected early in pregnancy. Maternal age might influence PFAS placental transfer. Copyright © 2015 Elsevier Inc. All rights reserved.
Loukotková, Lucie; VonTungeln, Linda S; Vanlandingham, Michelle; da Costa, Gonçalo Gamboa
2018-01-01
According to the World Health Organization, the consumption of tobacco products is the single largest cause of preventable deaths in the world, exceeding the total aggregated number of deaths caused by diseases such as AIDS, tuberculosis, and malaria. An important element in the evaluation of the health risks associated with the consumption of tobacco products is the assessment of the internal exposure to the tobacco constituents responsible for their addictive (e.g. nicotine) and carcinogenic (e.g. N-nitrosamines such as NNN and NNK) properties. However, the assessment of the serum levels of these compounds is often challenging from an analytical standpoint, in particular when limited sample volumes are available and low detection limits are required. Currently available analytical methods often rely on complex multi-step sample preparation procedures, which are prone to low analyte recoveries and ex-vivo contamination due to the ubiquitous nature of these compounds as background contaminants. In order to circumvent these problems, we report a facile and highly sensitive method for the simultaneous quantification of nicotine, cotinine, NNN, and NNK in serum samples. The method relies on a simple "one pot" liquid-liquid extraction procedure and isotope dilution ultra-high pressure (UPLC) hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry. The method requires only 10μL of serum and presents a limit of quantification of 0.02nmol (3000pg/mL) nicotine, 0.6pmol (100pg/mL) cotinine, 0.05pmol NNK (10pg/mL), and 0.06pmol NNN (10pg/mL), making it appropriate for pharmacokinetic evaluations. Published by Elsevier B.V.
Aydemir, Duygu; Karabulut, Gözde; Şimşek, Gülsu; Gok, Muslum; Barlas, Nurhayat; Ulusu, Nuriye Nuray
2018-04-13
Di(2-ethylhexyl) phthalate (DEHP) is a widely used synthetic polymer in the industry. DEHP may induce reproductive and developmental toxicity, obesity, carcinogenesis and cause abnormal endocrine function in both human and wildlife. The aim of this study was to investigate trace element and mineral levels in relation of kidney and liver damage in DEHP-administered rats. Therefore, prepubertal male rats were dosed with 0, 100, 200, and 400 mg/kg/day of DEHP. At the end of the experiment, trace element and mineral levels, glucose-6-phosphate dehydrogenase (G6PD), 6-phosphogluconate dehydrogenase (6-PGD), glutathione reductase (GR) and glutathione S-transferase (GST) enzyme activities were evaluated in the serum, liver, and kidney samples of rats. Furthermore, serum clinical biochemistry parameters, organ/body weight ratios and histological changes were investigated to evaluate impact of DEHP more detailed. Our data indicated that sodium (Na), calcium (Ca), potassium (K), lithium (Li), rubidium (Rb) and cesium (Cs) levels significantly decreased, however iron (Fe) and selenium (Se) concentrations significantly increased in DEHP-administered groups compared to the control in the serum samples. On the other hand, upon DEHP administration, selenium concentration, G6PD and GR activities were significantly elevated, however 6-PGD activity significantly decreased compared to the control group in the kidney samples. Decreased G6PD activity was the only significant change between anti-oxidant enzyme activities in the liver samples. Upon DEHP administration, aberrant serum biochemical parameters have arisen and abnormal histological changes were observed in the kidney and liver tissue. In conclusion, DEHP may induce liver and kidney damage, also result abnormalities in the trace element and mineral levels.
Long-term stability of glucose: glycolysis inhibitor vs. gel barrier tubes.
Winter, Theresa; Hannemann, Anke; Suchsland, Juliane; Nauck, Matthias; Petersmann, Astrid
2018-03-12
Measuring the glucose concentration in whole blood samples is critical due to unsatisfactory glycolysis inhibition. Previous studies showed that Terumo tubes were superior, but they were taken off the European market in 2016 and alternatives were required. This initiated the present evaluation of glucose stability in five available tube types. Venous blood samples were collected from 61 healthy volunteers to test tubes supplied by Terumo (two sets), Greiner FC-Mix, BD FX-Mixture and BD serum. After sampling, the contents were thoroughly mixed and centrifuged within an hour. The glucose concentrations were determined and the samples resuspended except for BD serum tubes (gel barrier). The first 30 samples were stored at room temperature and the remaining 31 at 4°C. After 24, 48, 72 and 96 h, all tubes were (re)centrifuged, and glucose concentration measurements were repeated. Changes in glucose concentrations over time differed significantly between the investigated tube types and to a certain extent between the two storing conditions. Glycolysis was most evident in the BD FX-mixture tubes. Good glucose stability was observed in samples retrieved form BD serum and Greiner tubes. The stability in both Terumo tubes was comparable to that in other studies. Although Greiner and both Terumo tubes are supposed to contain the same glycolysis inhibitor, glucose stability differed between these tubes. We showed that Greiner is an acceptable alternative to Terumo and that glucose in serum that was rapidly separated from corpuscles by a gel barrier is stable for an extended time.
2014-01-01
Background Estimation of the quantity of colostral IgG or serum IgG absorbed following ingestion of colostrum by calves is essential for monitoring the effectiveness of colostrum feeding practices on dairy farms. Milk total solids concentrations determination is a critical part of quality assessment of nonsaleable whole milk prior to feeding to calves. To date, on-farm methods to assess colostral IgG, serum IgG or milk total solids concentrations have been performed separately with various instruments. The objective of this study was to evaluate the diagnostic performance of a single electronic, hand-held refractometer for assessing colostral and serum IgG concentrations and milk total solids in dairy cattle. Colostral IgG, serum IgG and milk total solids concentrations were determined by the refractometer. Corresponding analysis of colostral and serum IgG concentrations were determined by radial immunodiffusion (RID) while milk total solids were determined by spectrophotometry. Sensitivity and specificity of the refractometer for colostrum and serum samples were calculated as determined by RID. Sensitivity and specificity of the refractometer for milk samples was calculated as determined by spectrophotometry. Results The sensitivity of the refractometer was 1 for colostral IgG, serum IgG and milk total solids determinations. Specificity of the refractometer was 0.66, 0.24 and 0 for colostral IgG, serum IgG and milk total solids determinations, respectively. The refractometer underestimated colostral IgG, serum IgG and milk total solids concentrations compared to the concentrations determined by RID or spectrophotometry. Conclusions The refractometer was an acceptable, rapid, convenient on-farm method for determining colostral IgG and milk total solids. The refractometer was not an acceptable method for determination of serum IgG concentrations as it severely underestimated the serum IgG concentrations. PMID:25125217
Cai, Jie; Wu, Meng; Ren, Jie; Du, Yali; Long, Zhangbiao; Li, Guoxun; Han, Bing; Yang, Lichen
2017-05-02
Our aim was to evaluate the cut-off value and efficiency of using reticulocyte hemoglobin content as a marker to diagnose iron deficiency anemia in Chinese adults. 140 adults who needed bone marrow aspiration for diagnosis at the hematology department of the Peking Union Medical College Hospital were enrolled according to the inclusive and exclusive criteria. Venous blood samples were collected to detect complete blood count, including hemoglobin, reticulocyte hemoglobin content, hematocrit, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, free erythrocyte protoporphyrin; iron indexes of serum ferritin, serum transferrin receptor, and unsaturated iron-binding capacity; and inflammation markers of C-reactive protein and α-acid glycoprotein. Bone marrow samples were obtained for the bone marrow iron staining, which was used as the standard for the evaluation of iron status in this study. Subjects were divided into three groups according to hemoglobin levels and bone marrow iron staining results: the IDA (iron deficiency anemia) group, the NIDA (non-iron deficiency anemia) group, and the control group. The differences of the above-mentioned indexes were compared among the three groups and the effect of inflammation was also considered. The cut-off value of reticulocyte hemoglobin content was determined by receiver operation curves. The IDA group ( n = 56) had significantly lower reticulocyte hemoglobin content, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, and serum ferritin; and higher free erythrocyte protoporphyrin, unsaturated iron-binding capacity, and serum transferrin receptor ( p < 0.05) compared with the NIDA group ( n = 38) and control group ( n = 46). Hematocrit, serum ferritin, and unsaturated iron-binding capacity were significantly affected by inflammation while reticulocyte hemoglobin content and other parameters were not. The cut-off value of reticulocyte hemoglobin content for diagnosing iron deficiency anemia was 27.2 pg, with a sensitivity of 87.5% and a specificity of 92.9%. The cut-off values for mean cellular volume, serum ferritin, and serum transferrin receptor were 76.6, 12.9, and 4.89 mg/L, respectively. Reticulocyte hemoglobin content had the largest area under the curve of 0.929, while those for mean cellular volume, serum ferritin, serum transferrin receptor were 0.922, 0.887, and 0.900, respectively. Reticulocyte hemoglobin content has a high sensitivity and specificity in the diagnosis of iron deficiency anemia, and its comprehensive diagnostic efficacy is better than other traditional indicators-such as serum ferritin and serum transferrin receptor.
Serum hyaluronic acid in dogs with congenital portosystemic shunts.
Seki, M; Asano, K; Sakai, M; Kanno, N; Teshima, K; Edamura, K; Tanaka, S
2010-05-01
To compare the serum level of hyaluronic acid in dogs with congenital portosystemic shunt with that in healthy dogs and to investigate the perioperative change in serum hyaluronic acid following shunt attenuation. Blood samples were obtained from 29 congenital portosystemic shunt dogs before the operation, and 2 and 4 weeks after the operation from 17 and 7 dogs, respectively. The serum hyaluronic acid level of these dogs was measured and compared with that of 10 healthy beagles. The median preoperative hyaluronic acid level in dogs with congenital portosystemic shunt was significantly elevated compared with that in healthy dogs. Furthermore, the median postoperative hyaluronic acid level significantly decreased compared with the median preoperative levels in congenital portosystemic shunt dogs. In the case of dogs with congenital portosystemic shunt, the reduction of intrahepatic portal blood flow might lower the clearance rate of hyaluronic acid in hepatic sinusoidal endothelial cells, so hyaluronic acid clearance could be improved by attenuation of a shunt vessel. Hence, serum hyaluronic acid levels might be useful to evaluate liver function and also have the potential to evaluate successful attenuation of a shunt vessel in dogs with congenital portosystemic shunt. Further investigations are required to clarify whether serum hyaluronic acid offers significant benefits over existing markers such as serum bile acid or ammonia concentrations.
Hemolysis associated with pneumatic tube system transport for blood samples
Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih
2014-01-01
Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830
Evidence to Support a Contribution of Polyreactive Antibodies to HLA Serum Reactivity.
Gao, Baoshan; Rong, Chunshu; Porcheray, Fabrice; Moore, Carolina; Girouard, Timothy C; Saidman, Susan L; Wong, Waichi; Fu, Yaowen; Zorn, Emmanuel
2016-01-01
Assessing the serum reactivity to HLA is essential for the evaluation of transplant candidates and the follow-up of allograft recipients. In this study, we look for evidence at the clonal level that polyreactive antibodies cross-reactive to apoptotic cells and multiple autoantigens can also react to HLA and contribute to the overall serum reactivity. We immortalized B cell clones from the blood of 2 kidney transplant recipients and characterized their reactivity to self-antigens, apoptotic cells as well as native, denatured, and cryptic HLA determinants using enzyme-linked immunosorbent assay (ELISA), immunofluorescence, flow cytometry and Luminex assays. We also assessed the reactivity of 300 pretransplant serum specimens to HLA and apoptotic cells. We report here 4 distinct B cell clones cross-reactive to self and HLA class I. All 4 clones reacted to numerous HLA class I alleles but did not appear to target canonical "shared" epitopes. In parallel experiments, we observed a strong correlation between IgG reactivity to HLA and apoptotic cells in pretransplant serum samples collected from 300 kidney transplant recipients. Further analysis revealed that samples with higher reactivity to apoptotic cells displayed significantly higher class I percent panel-reactive antibodies compared to samples with low reactivity to apoptotic cells. We provide here (1) proof of principle at the clonal level that human polyreactive antibodies can cross-react to HLA, multiple self-antigens and apoptotic cells and (2) supportive evidence that polyreactive antibodies contribute to overall HLA reactivity in the serum of patients awaiting kidney transplant.
Massive glutamine cyclization to pyroglutamic acid in human serum discovered using NMR spectroscopy.
Nagana Gowda, G A; Gowda, Yashas N; Raftery, Daniel
2015-04-07
Glutamine is one of the most abundant metabolites in blood and is a precursor as well as end product central to numerous important metabolic pathways. A number of surprising and unexpected roles for glutamine, including cancer cell glutamine addiction discovered recently, stress the importance of accurate analysis of glutamine concentrations for understanding its role in health and numerous diseases. Utilizing a recently developed NMR approach that offers access to an unprecedented number of quantifiable blood metabolites, we have identified a surprising glutamine cyclization to pyroglutamic acid that occurs during protein removal. Intact, ultrafiltered and protein precipitated samples from the same pool of human serum were comprehensively investigated using (1)H NMR spectroscopy at 800 MHz to detect and quantitatively evaluate the phenomenon. Interestingly, although glutamine cyclization occurs in both ultrafiltered and protein precipitated serum, the cyclization was not detected in intact serum. Strikingly, due to cyclization, the apparent serum glutamine level drops by up to 75% and, concomitantly, the pyroglutamic acid level increases proportionately. Further, virtually under identical conditions, the magnitude of cyclization is vastly different for different portions of samples from the same pool of human serum. However, the sum of glutamine and pyroglutamic acid concentrations in each sample remains the same for all portions. These unexpected findings indicate the importance of considering the sum of apparent glutamine and pyroglutamic acid levels, obtained from the contemporary analytical methods, as the actual blood glutamine level for biomarker discovery and biological interpretations.
Alarmins and Clinical Outcomes After Major Abdominal Surgery-A Prospective Study.
Máca, Jan; Burša, Filip; Ševčík, Pavel; Sklienka, Peter; Burda, Michal; Holub, Michal
2017-06-01
Tissue injury causing immune response is an integral part of surgical procedure. Evaluation of the degree of surgical trauma could help to improve postoperative management and determine the clinical outcomes. We analyzed serum levels of alarmins, including S100A5, S100A6, S100A8, S100A9, S100A11, and S100A12; high-mobility group box 1; and heat-shock protein 70, after elective major abdominal surgery (n = 82). Blood samples were collected for three consecutive days after surgery. The goals were to evaluate the relationships among the serum levels of alarmins and selected surgical characteristics and to test potential of alarmins to predict the clinical outcomes. Significant, positive correlations were found for high-mobility group box 1 with the length of surgery, blood loss, and intraoperative fluid intake for all three days of blood sampling. The protein S100A8 serum levels showed positive correlations with intensive care unit length of stay, 28-day and in-hospital mortality. The protein S100A12 serum levels had significant, positive correlations with intensive care unit length of stay, 28-day mortality, and in-hospital mortality. We did not find significant differences in alarmin levels between cancer and noncancer subjects. The high-mobility group box 1 serum levels reflect the degree of surgical injury, whereas proteins S100A8 and S100A12 might be considered good predictors of major abdominal surgery morbidity and mortality.
Gong, Zhong-Ying; Lv, Gao-Peng; Gao, Li-Na; Lu, Yi; Guo, Jie; Zang, Da-Wei
2018-06-13
There are no reliable biomarkers that could evaluate the disease burden in amyotrophic lateral sclerosis (ALS). The aim of our study is to evaluate the changes in cerebrospinal fluid (CSF) and serum neurofilament subunit L (NF-L) in patients with ALS and to analyze the correlations between the levels of NF-L and clinical parameters. CSF and serum samples were obtained from 80 ALS patients and 40 controls. The levels of NF-L in CSF and serum were assessed, and disease progression parameters including duration, revised ALS Functional Rating Scale (ALSFRS-r) score, disease progression rate (DPR), upper motor neuron (UMN) score, and survival were analyzed by registered neurologists. All samples were measured using a commercial enzyme-linked immunosorbent assay. Statistical analyses were performed using Prism software. Compared to the controls, the ALS patients displayed significantly increased levels of NF-L; these values were negatively correlated with the ALSFRS-r score and positively correlated with the decrease in ALSFRS-r score, DPR, and UMN score. There was no correlation between levels of NF-L and duration. In addition, the cumulative survival rate in ALS patients with a low level of NF-L was higher than in patients with a high level of NF-L. NF-L levels increased in CSF and serum of patients with ALS. NF-L may thus be a neurodegenerative biomarker for predicting ALS severity and progression, and the survival of patients with this disease. © 2018 S. Karger AG, Basel.
Expression of microRNAs of C19MC in Different Histological Types of Testicular Germ Cell Tumour.
Flor, Inga; Spiekermann, Meike; Löning, Thomas; Dieckmann, Klaus-Peter; Belge, Gazanfer; Bullerdiek, Jörn
2016-01-01
Testicular germ cell tumours (TGCTs) are the most common tumours in men aged from 20 to 40 years, with a steadily increasing incidence. This study aimed to characterize the expression of the miRNA cluster C19MC in TGCT and to evaluate the suitability of a C19MC miRNA as a serum biomarker. By quantitative reverse transcription PCR, we measured the expression of miR-517a-3p, miR-519a-3p, and miR-519c 3p in tissue samples of 25 TGCTs and the level of miR-517a-3p in serum samples obtained pre- and postoperatively from the same patients. We detected a significantly higher expression of C19MC miRNAs in non-seminomas than in seminomas and in clinical stages 2 and 3 than in stage 1 in both tissue and serum samples. miRNAs of C19MC are overexpressed in more aggressive types of TGCT, suggesting they contribute to malignancy. Furthermore, they might serve as serum biomarkers for these types of TGCT. Copyright© 2016, International Institute of Anticancer Research (Dr. John G. Delinasios), All rights reserved.
Serum lipid concentrations in six canid and four ursid species in four zoos.
Crissey, Susan D; Ange, Kimberly D; Slifka, Kerri A; Sadler, William; Kahn, Stephen; Ward, Ann M
2004-03-01
Serum lipid levels were measured in healthy captive wild canids and ursids, and the values were compared with previously published data. Serum lipid levels were evaluated in blood samples collected from eight African wild dogs (Lycaon pictus), three arctic foxes (Alopex lagopus), nine gray wolves (Canis lupus), four maned wolves (Chrysocyon brachyurus), two Mexican wolves (Canis lupus baleiyi), nine red wolves (Canis rufus), two brown bears (Ursus arctos), six polar bears (Ursus maritimus), six spectacled bears (Tremarctos ornatus), and five sun bears (Ursus malayanus). Samples were analyzed for total cholesterol, triacylglycerides, high-density lipoprotein-cholesterol, and low-density lipoprotein-cholesterol. Although the results showed a great variation among species, circulating lipids appeared especially high, sometimes extremely so, in the spectacled bears, polar bears, sun bears, and maned wolves compared with all other species sampled. The study provides a substantial basis for comparing lipid levels in presumed healthy animals and indicates a need for controlled study of the effects of diet on circulating lipid levels.
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-09-24
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70-200 mg/dL), revealing high system performance for a wide glycemic state range (45-500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting.
Dengue-yellow fever sera cross-reactivity; challenges for diagnosis.
Houghton-Triviño, Natalia; Montaña, Diana; Castellanos, Jaime
2008-01-01
The Flavivirus genera share epitopes inducing cross-reactive antibodies leading to great difficulty in differentially diagnosing flaviviral infections. This work was aimed at evaluating the complexity of dengue and yellow fever serological differential diagnosis. Dengue antibody capture ELISA and a yellow fever neutralisation test were carried out on 13 serum samples obtained from yellow fever patients, 20 acute serum samples from dengue patients and 19 voluntary serum samples pre- and post-vaccination with YF vaccine. Dengue ELISA revealed IgM reactivity in 46,2 % of yellow fever patients and 42 % of vaccinees. Sixteen out of 20 dengue patients (80 %) had high YF virus neutralisation titres. Such very high cross-reactivity data challenged differential laboratory diagnosis of dengue and yellow fever in areas where both flaviviruses co-circulate. New laboratory strategies are thus needed for improving the tests and providing a specific laboratory diagnosis. Cross-reactivity between Flaviviruses represents a great difficulty for epidemiological surveillance and preventing dengue, both of which demand urgent attention.
Michalke, Bernhard; Kramer, Matthias F; Brehler, Randolf
2018-02-21
Aluminium is associated with disorders and is the commonly used vaccine adjuvant. Understanding the mechanisms of how Al is transported, metabolized or of its toxicity depends on the knowledge of Al-interactions with bioligands, i.e. Al-species. Al-speciation in serum is difficult because of low concentration and the risk of exogenous Al contamination. Furthermore, Al-measurements may be hampered according to various interferences. This study aims for developing quality controlled protocols for reliable Al- and Al-species determination and for investigating probable differences in Al (-speciation) after Al-containing subcutaneous immunotherapy (SIT). Sample donors were recruited either for the control group ("class-0", they never had been treated with SIT containing an Al-depot extract) or for the SIT-group ("class-1", they previously had been treated with SIT for insect venom allergy with an Al-depot extract). Blood was drawn for medical reasons and serum prepared. Additionally, some sample donors collected 24-h-urine. They had been informed (and they consented) about the scientific use of their samples. The study was approved by the ethic committee of the "Medical Association Westphalia-Lippe" and of the University of Münster, evaluating the study positively (No. 2013-667-f-S). We applied quality controlled sample preparation and interference-free Al detection by ICP sectorfield-mass spectrometry. Al-species were analysed using size-exclusion-chromatography-ICP-qMS. Al-concentrations or speciation in urine samples showed no differences between class-0 and class-1. Al-citrate was the main uric Al-species. In serum elevated Al-concentrations were found for both classes, with class-1 samples being significantly higher than class-0 (p = 0.041), but class-0 samples being approximately 10-fold too high compared to reference values from non-exposed persons. We identified gel-monovettes as contamination source. In contamination-free samples from HNO 3 -prewashed gel-free monovettes (n = 27) there was no difference in the serum Al concentration between the two patient groups (p = 0.669) INTERPRETATION: Thorough cleaning of sample preparation ware and use of gel-free monovettes is decisive for an accurate Al analysis in serum. Without these steps, wrong analysis and wrong conclusions are likely. We conclude that gel-monovettes are unsuitable for blood sampling with subsequent Al-analysis. Whether Al in serum is elevated after SIT treatment containing an Al-depot extract, or not, remains inconclusive as the non-contaminated sample size was small. Copyright © 2018 Elsevier GmbH. All rights reserved.
Transition diseases in grazing dairy cows are related to serum cholesterol and other analytes.
Sepúlveda-Varas, Pilar; Weary, Daniel M; Noro, Mirela; von Keyserlingk, Marina A G
2015-01-01
The objectives of this study were to describe the incidence of postpartum disease and to evaluate the association with serum cholesterol concentrations during the first 3 weeks after calving in grazing dairy cows. The association between non-esterified fatty acids (NEFA), β-hydroxybutyrate (BHBA), calcium and postpartum diseases was also evaluated. A total of 307 Holstein dairy cows from 6 commercial grazing herds in Osorno, Chile, were monitored from calving until 21 days in milk. Cases of retained placenta, clinical hypocalcemia and clinical mastitis were recorded by the farmer using established definitions. Twice weekly, cows were evaluated for metritis by the same veterinarian based on vaginal discharge and body temperature. Postpartum blood samples were collected weekly and analyzed for serum concentrations of cholesterol, NEFA, BHBA and calcium. Cows were considered as having subclinical ketosis if BHBA >1.2 mmol/L, and subclinical hypocalcemia if calcium <2.0 mmol/L in any of the 3 weekly samples. Overall, 56% of the cows studied developed at least one clinical or subclinical disease after calving. Incidence of individual diseases was 8.8% for retained placenta, 4.2% for clinical hypocalcemia, 11.7% for clinical mastitis, 41.1% for metritis, 19.9% for subclinical hypocalcemia and 16.6% for subclinical ketosis. Lower postpartum cholesterol in cows was associated with developing severe metritis or having more than one clinical disease after calving. For every 0.4 mmol/L decrease in serum cholesterol cows were nearly twice as likely to be diagnosed with multiple clinical diseases after calving. Higher BHBA concentrations and lower calcium concentrations during week 1 were associated with severe cases of metritis. Low serum calcium concentration during week 1 was also associated with developing more than one clinical disorder after calving. In conclusion, the incidence of postpartum diseases can be high even in grazing herds and lower serum cholesterol concentrations were associated with occurrence of clinical postpatum disorders.
Transition Diseases in Grazing Dairy Cows Are Related to Serum Cholesterol and Other Analytes
2015-01-01
The objectives of this study were to describe the incidence of postpartum disease and to evaluate the association with serum cholesterol concentrations during the first 3 weeks after calving in grazing dairy cows. The association between non-esterified fatty acids (NEFA), β-hydroxybutyrate (BHBA), calcium and postpartum diseases was also evaluated. A total of 307 Holstein dairy cows from 6 commercial grazing herds in Osorno, Chile, were monitored from calving until 21 days in milk. Cases of retained placenta, clinical hypocalcemia and clinical mastitis were recorded by the farmer using established definitions. Twice weekly, cows were evaluated for metritis by the same veterinarian based on vaginal discharge and body temperature. Postpartum blood samples were collected weekly and analyzed for serum concentrations of cholesterol, NEFA, BHBA and calcium. Cows were considered as having subclinical ketosis if BHBA >1.2 mmol/L, and subclinical hypocalcemia if calcium <2.0 mmol/L in any of the 3 weekly samples. Overall, 56% of the cows studied developed at least one clinical or subclinical disease after calving. Incidence of individual diseases was 8.8% for retained placenta, 4.2% for clinical hypocalcemia, 11.7% for clinical mastitis, 41.1% for metritis, 19.9% for subclinical hypocalcemia and 16.6% for subclinical ketosis. Lower postpartum cholesterol in cows was associated with developing severe metritis or having more than one clinical disease after calving. For every 0.4 mmol/L decrease in serum cholesterol cows were nearly twice as likely to be diagnosed with multiple clinical diseases after calving. Higher BHBA concentrations and lower calcium concentrations during week 1 were associated with severe cases of metritis. Low serum calcium concentration during week 1 was also associated with developing more than one clinical disorder after calving. In conclusion, the incidence of postpartum diseases can be high even in grazing herds and lower serum cholesterol concentrations were associated with occurrence of clinical postpatum disorders. PMID:25807462
Fontanari, Anna Martha Vaitses; Costa, Angelo Brandelli; Aguiar, Bianca; Tusset, Cíntia; Andreazza, Tahiana; Schneider, Maiko; da Rosa, Eduarda Dias; Soll, Bianca Machado Borba; Schwarz, Karine; da Silva, Dhiordan Cardoso; Borba, André Oliveira; Mueller, Andressa; Massuda, Raffael; Lobato, Maria Inês Rodrigues
2016-09-06
Serum BDNF levels are significantly decreased in transsexual Brazilian women when compared to cis-sexual men. Since transsexual men are also exposed to chronic social stress and have a high prevalence of associated psychopathologies, it is plausible to inquire if BDNF serum levels are altered in transsexual men as well. Therefore, our objective was to evaluate differences in BDNF serum level of transsexual men when compared to cis-sexual men and women. Our sample comprises 27 transsexual men, 31 cis-sexual women and 30 cis-sexual men recruited between 2011 and 2015. We observed that BDNF serum concentration is decreased in transsexual men comparing to cis-sexual men and women. Cross-sex hormone treatment, chronic social stress or long-term gender dysphoria (GD) could explain the variation found in BDNF serum levels. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Maudry, Arnaud; Chene, Gautier; Chatelain, Rémi; Patural, Hugues; Bellete, Bahrie; Tisseur, Bernard; Hafid, Jamal; Raberin, Hélène; Beretta, Sophie; Sung, Roger Tran Manh; Belot, Georges; Flori, Pierre
2009-09-01
A comparative study of the Toxoplasma IgG(I) and IgG(II) Access (Access I and II, respectively; Beckman Coulter Inc.), AxSYM Toxo IgG (AxSYM; Abbott Diagnostics), Vidas Toxo IgG (Vidas; bioMerieux, Marcy l'Etoile, France), Immulite Toxo IgG (Immulite; Siemens Healthcare Diagnostics Inc.), and Modular Toxo IgG (Modular; Roche Diagnostics, Basel, Switzerland) tests was done with 406 consecutive serum samples. The Toxo II IgG Western blot (LDBio, Lyon, France) was used as a reference technique in the case of intertechnique discordance. Of the 406 serum samples tested, the results for 35 were discordant by the different techniques. Using the 175 serum samples with positive results, we evaluated the standardization of the titrations obtained (in IU/ml); the medians (second quartiles) obtained were 9.1 IU/ml for the AxSYM test, 21 IU/ml for the Access I test, 25.7 IU/ml for the Access II test, 32 IU/ml for the Vidas test, 34.6 IU/ml for the Immulite test, and 248 IU/ml for the Modular test. For all the immunoassays tested, the following relative sensitivity and specificity values were found: 89.7 to 100% for the Access II test, 89.7 to 99.6% for the Immulite test, 90.2 to 99.6% for the AxSYM test, 91.4 to 99.6% for the Vidas test, 94.8 to 99.6% for the Access I test, and 98.3 to 98.7% for the Modular test. Among the 406 serum samples, we did not find any false-positive values by two different tests for the same serum sample. Except for the Modular test, which prioritized sensitivity, it appears that the positive cutoff values suggested by the pharmaceutical companies are very high (either for economical or for safety reasons). This led to imperfect sensitivity, a large number of unnecessary serological follow-ups of pregnant women, and difficulty in determining the serological status of immunosuppressed individuals.
Springer, Jan; White, P Lewis; Hamilton, Shanna; Michel, Denise; Barnes, Rosemary A; Einsele, Hermann; Löffler, Juergen
2016-03-01
Standardized methodologies for the molecular detection of invasive aspergillosis (IA) have been established by the European Aspergillus PCR Initiative for the testing of whole blood, serum, and plasma. While some comparison of the performance of Aspergillus PCR when testing these different sample types has been performed, no single study has evaluated all three using the recommended protocols. Standardized Aspergillus PCR was performed on 423 whole-blood pellets (WBP), 583 plasma samples, and 419 serum samples obtained from hematology patients according to the recommendations. This analysis formed a bicenter retrospective anonymous case-control study, with diagnosis according to the revised European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (11 probable cases and 36 controls). Values for clinical performance using individual and combined samples were calculated. For all samples, PCR positivity was significantly associated with cases of IA (for plasma, P = 0.0019; for serum, P = 0.0049; and for WBP, P = 0.0089). Plasma PCR generated the highest sensitivity (91%); the sensitivities for serum and WBP PCR were 80% and 55%, respectively. The highest specificity was achieved when testing WBP (96%), which was significantly superior to the specificities achieved when testing serum (69%, P = 0.0238) and plasma (53%, P = 0.0002). No cases were PCR negative in all specimen types, and no controls were PCR positive in all specimens. This study confirms that Aspergillus PCR testing of plasma provides robust performance while utilizing commercial automated DNA extraction processes. Combining PCR testing of different blood fractions allows IA to be both confidently diagnosed and excluded. A requirement for multiple PCR-positive plasma samples provides similar diagnostic utility and is technically less demanding. Time to diagnosis may be enhanced by testing multiple contemporaneously obtained sample types. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Bi, Cong; Zheng, Xiwei; Hage, David S
2016-02-05
In the circulatory system, many drugs are reversibly bound to serum proteins such as human serum albumin (HSA) and alpha1-acid glycoprotein (AGP), resulting in both free and protein-bound fractions for these drugs. This report examined the use of microcolumns containing immobilized AGP for the measurement of free drug fractions by ultrafast affinity extraction and a two-dimensional affinity system. Several drugs known to bind AGP were used as models to develop and evaluate this approach. Factors considered during the creation of this method included the retention of the drugs on the microcolumns, the injection flow rate, the microcolumn size, and the times at which a second AGP column was placed on-line with the microcolumn. The final system had residence times of only 110-830ms during sample passage through the AGP microcolumns and allowed free drug fractions to be determined within 10-20min when using only 3-10μL of sample per injection. This method was used to measure the free fractions of the model drugs at typical therapeutic levels in serum, giving good agreement with the results obtained by ultrafiltration. This approach was also used to estimate the binding constants for each drug with AGP in serum, even for drugs that had significant interactions with both AGP and HSA in such samples. These results indicated that AGP microcolumns could be used with ultrafast affinity extraction to measure free drug fractions in a label-free manner and to study the binding of drugs with AGP in complex samples such as serum. Copyright © 2015 Elsevier B.V. All rights reserved.
A Systematic Evaluation of Blood Serum and Plasma Pre-Analytics for Metabolomics Cohort Studies
Jobard, Elodie; Trédan, Olivier; Postoly, Déborah; André, Fabrice; Martin, Anne-Laure; Elena-Herrmann, Bénédicte; Boyault, Sandrine
2016-01-01
The recent thriving development of biobanks and associated high-throughput phenotyping studies requires the elaboration of large-scale approaches for monitoring biological sample quality and compliance with standard protocols. We present a metabolomic investigation of human blood samples that delineates pitfalls and guidelines for the collection, storage and handling procedures for serum and plasma. A series of eight pre-processing technical parameters is systematically investigated along variable ranges commonly encountered across clinical studies. While metabolic fingerprints, as assessed by nuclear magnetic resonance, are not significantly affected by altered centrifugation parameters or delays between sample pre-processing (blood centrifugation) and storage, our metabolomic investigation highlights that both the delay and storage temperature between blood draw and centrifugation are the primary parameters impacting serum and plasma metabolic profiles. Storing the blood drawn at 4 °C is shown to be a reliable routine to confine variability associated with idle time prior to sample pre-processing. Based on their fine sensitivity to pre-analytical parameters and protocol variations, metabolic fingerprints could be exploited as valuable ways to determine compliance with standard procedures and quality assessment of blood samples within large multi-omic clinical and translational cohort studies. PMID:27929400
Urine colorimetry for therapeutic drug monitoring of pyrazinamide during tuberculosis treatment.
Zentner, Isaac; Modongo, Chawangwa; Zetola, Nicola M; Pasipanodya, Jotam G; Srivastava, Shashikant; Heysell, Scott K; Mpagama, Stellah; Schlect, Hans P; Gumbo, Tawanda; Bisson, Gregory P; Vinnard, Christopher
2018-03-01
Pyrazinamide is a key drug in the first-line treatment regimen for tuberculosis, with a potent sterilizing effect. Although low pyrazinamide peak serum concentrations (C max ) are associated with poor treatment outcomes, many resource-constrained settings do not have sufficient laboratory capacity to support therapeutic drug monitoring (TDM). The objective of this study was to determine whether a colorimetric test of urine can identify tuberculosis patients with adequate pyrazinamide exposures, as defined by serum C max above a target threshold. In the derivation study of healthy volunteers, three dose sizes of pyrazinamide were evaluated, and intensive pharmacokinetic blood sampling was performed over an 8-h period, with a timed urine void at 4h post-dosing. Pyrazinamide in urine was isolated by spin column centrifugation with an exchange resin, followed by colorimetric analysis; the absorbance peak at 495nm was measured. The urine assay was then evaluated in a study of 39 HIV/tuberculosis patients in Botswana enrolled in an intensive pharmacokinetic study. Receiver operating characteristics (ROC) curves were used to measure diagnostic accuracy. The guideline-recommended pyrazinamide serum C max target of 35mg/l was evaluated in the primary analysis; this target was found to be predictive of favorable outcomes in a clinical study. Following this, a higher serum C max target of 58mg/l was evaluated in the secondary analysis. At the optimal cut-off identified in the derivation sample, the urine colorimetric assay was 97% sensitive and 50% specific to identify 35 of 39 HIV/tuberculosis patients with pharmacokinetic target attainment, with an area under the ROC curve of 0.81 (95% confidence interval 0.60-0.97). Diagnostic accuracy was lower at the 58mg/l serum C max target, with an area under the ROC curve of 0.68 (95% confidence interval 0.48-0.84). Men were less likely than women to attain either serum pharmacokinetic target. The urine colorimetric assay was sensitive but not specific for the detection of adequate pyrazinamide pharmacokinetic exposures among HIV/tuberculosis patients in a high-burden setting. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Marchitti, Satori A.; Fenton, Suzanne E.; Mendola, Pauline; Kenneke, John F.; Hines, Erin P.
2016-01-01
Background: Serum concentrations of polybrominated diphenyl ethers (PBDEs) in U.S. women are believed to be among the world’s highest; however, little information exists on the partitioning of PBDEs between serum and breast milk and how this may affect infant exposure. Objectives: Paired milk and serum samples were measured for PBDE concentrations in 34 women who participated in the U.S. EPA MAMA Study. Computational models for predicting milk PBDE concentrations from serum were evaluated. Methods: Samples were analyzed using gas chromatography isotope-dilution high-resolution mass spectrometry. Observed milk PBDE concentrations were compared with model predictions, and models were applied to NHANES serum data to predict milk PBDE concentrations and infant intakes for the U.S. population. Results: Serum and milk samples had detectable concentrations of most PBDEs. BDE-47 was found in the highest concentrations (median serum: 18.6; milk: 31.5 ng/g lipid) and BDE-28 had the highest milk:serum partitioning ratio (2.1 ± 0.2). No evidence of depuration was found. Models demonstrated high reliability and, as of 2007–2008, predicted U.S. milk concentrations of BDE-47, BDE-99, and BDE-100 appear to be declining but BDE-153 may be rising. Predicted infant intakes (ng/kg/day) were below threshold reference doses (RfDs) for BDE-99 and BDE-153 but above the suggested RfD for BDE-47. Conclusions: Concentrations and partitioning ratios of PBDEs in milk and serum from women in the U.S. EPA MAMA Study are presented for the first time; modeled predictions of milk PBDE concentrations using serum concentrations appear to be a valid method for estimating PBDE exposure in U.S. infants. Citation: Marchitti SA, Fenton SE, Mendola P, Kenneke JF, Hines EP. 2017. Polybrominated diphenyl ethers in human milk and serum from the U.S. EPA MAMA Study: modeled predictions of infant exposure and considerations for risk assessment. Environ Health Perspect 125:706–713; http://dx.doi.org/10.1289/EHP332 PMID:27405099
Oral cancer screening: serum Raman spectroscopic approach
NASA Astrophysics Data System (ADS)
Sahu, Aditi K.; Dhoot, Suyash; Singh, Amandeep; Sawant, Sharada S.; Nandakumar, Nikhila; Talathi-Desai, Sneha; Garud, Mandavi; Pagare, Sandeep; Srivastava, Sanjeeva; Nair, Sudhir; Chaturvedi, Pankaj; Murali Krishna, C.
2015-11-01
Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, disease controls, and oral cancer groups. Spectra were acquired using a Raman microprobe. Spectral findings suggest changes in amino acids, lipids, protein, DNA, and β-carotene across the groups. A patient-wise approach was employed for data analysis using principal component linear discriminant analysis. In the first step, the classification among premalignant, disease control (nonoral cancer), oral cancer, and normal samples was evaluated in binary classification models. Thereafter, two screening-friendly classification approaches were explored to further evaluate the clinical utility of serum RS: a single four-group model and normal versus abnormal followed by determining the type of abnormality model. Results demonstrate the feasibility of premalignant and specific cancer detection. The normal versus abnormal model yields better sensitivity and specificity rates of 64 and 80% these rates are comparable to standard screening approaches. Prospectively, as the current screening procedure of visual inspection is useful mainly for high-risk populations, serum RS may serve as a useful adjunct for early and specific detection of oral precancers and cancer.
Ambient Ionization Mass Spectrometry Measurement of Aminotransferase Activity
NASA Astrophysics Data System (ADS)
Yan, Xin; Li, Xin; Zhang, Chengsen; Xu, Yang; Cooks, R. Graham
2017-06-01
A change in enzyme activity has been used as a clinical biomarker for diagnosis and is useful in evaluating patient prognosis. Current laboratory measurements of enzyme activity involve multi-step derivatization of the reaction products followed by quantitative analysis of these derivatives. This study simplified the reaction systems by using only the target enzymatic reaction and directly detecting its product. A protocol using paper spray mass spectrometry for identifying and quantifying the reaction product has been developed. Evaluation of the activity of aspartate aminotransferase (AST) was chosen as a proof-of-principle. The volume of sample needed is greatly reduced compared with the traditional method. Paper spray has a desalting effect that avoids sprayer clogging problems seen when examining serum samples by nanoESI. This very simple method does not require sample pretreatment and additional derivatization reactions, yet it gives high quality kinetic data, excellent limits of detection (60 ppb from serum), and coefficients of variation <10% in quantitation. [Figure not available: see fulltext.
Human Milk and Matched Serum Demonstrate Concentration of Select miRNAs.
Qin, Wenyi; Dasgupta, Santanu; Corradi, John; Sauter, Edward R
Pregnancy-associated breast cancers (PABCs), especially those diagnosed after childbirth, are often aggressive, with a poor prognosis. Factors influencing PABC are largely unknown. Micro(mi)RNAs are present in many human body fluids and shown to influence cancer development and/or growth. In six nursing mothers, we determined if breast cancer-associated miRNAs were (1) detectable in human breast milk and (2) if detectable, their relative expression in milk fractions compared to matched serum. We evaluated by quantitative PCR the expression of 11 cancer-associated miRNAs (10a-5p, 16, 21, 100, 140, 145, 155, 181, 199, 205, 212) in breast milk cells, fat and supernatant (skim milk), and matched serum. miRNA expression was detectable in all samples. For 10/11 miRNAs, mean relative expression compared to control (ΔCt) values was lowest in milk cells, the exception being miR205. Relative concentration was highest in the skim fraction of milk for all miRNAs. Expression was higher in skim milk than matched serum for 7/11 miRNAs and in serum for 4/11 miRNAs. miR205 expression was higher in all milk fractions than in matched serum. In conclusion, the expression of breast cancer-associated miRNAs is detectable in human breast milk and serum samples. The concentration is highest in skim milk, but is also detectable in milk fat and milk cells.
Serum creatinine and alkaline phosphatase levels are associated with severe chronic periodontitis.
Caúla, A L; Lira-Junior, R; Tinoco, E M B; Fischer, R G
2015-12-01
Periodontitis may alter systemic homeostasis and influence creatinine and alkaline phosphatase levels. Therefore, the aim of this study was to evaluate the relationship between severe chronic periodontitis and serum creatinine and alkaline phosphatase levels. One hundred patients were evaluated, 66 with severe chronic periodontitis (test group) and 34 periodontally healthy controls (control group). Medical, demographic and periodontal parameters were registered. Blood sample was collected after an overnight fast and serum creatinine and alkaline phosphatase levels were determined. There were significant differences between test and control groups in ethnicity, gender and educational level (p < 0.05). Patients with periodontitis showed a lower mean creatinine level (p < 0.05) and higher mean alkaline phosphatase level (p < 0.001) than the control group. There were significant correlations between periodontal parameters and serum creatinine and alkaline phosphatase levels. Severe chronic periodontitis was associated to lower creatinine and higher alkaline phosphatase levels. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Hart, Leslie B; Wells, Randall S; Kellar, Nick; Balmer, Brian C; Hohn, Aleta A; Lamb, Stephen V; Rowles, Teri; Zolman, Eric S; Schwacke, Lori H
2015-01-01
Inshore common bottlenose dolphins (Tursiops truncatus) are exposed to a broad spectrum of natural and anthropogenic stressors. In response to these stressors, the mammalian adrenal gland releases hormones such as cortisol and aldosterone to maintain physiological and biochemical homeostasis. Consequently, adrenal gland dysfunction results in disruption of hormone secretion and an inappropriate stress response. Our objective herein was to develop diagnostic reference intervals (RIs) for adrenal hormones commonly associated with the stress response (i.e., cortisol, aldosterone) that account for the influence of intrinsic (e.g., age, sex) and extrinsic (e.g., time) factors. Ultimately, these reference intervals will be used to gauge an individual's response to chase-capture stress and could indicate adrenal abnormalities. Linear mixed models (LMMs) were used to evaluate demographic and sampling factors contributing to differences in serum cortisol and aldosterone concentrations among bottlenose dolphins sampled in Sarasota Bay, Florida, USA (2000-2012). Serum cortisol concentrations were significantly associated with elapsed time from initial stimulation to sample collection (p<0.05), and RIs were constructed using nonparametric methods based on elapsed sampling time for dolphins sampled in less than 30 minutes following net deployment (95% RI: 0.91-4.21 µg/dL) and following biological sampling aboard a research vessel (95% RI: 2.32-6.68 µg/dL). To examine the applicability of the pre-sampling cortisol RI across multiple estuarine stocks, data from three additional southeast U.S. sites were compared, revealing that all of the dolphins sampled from the other sites (N = 34) had cortisol concentrations within the 95th percentile RI. Significant associations between serum concentrations of aldosterone and variables reported in previous studies (i.e., age, elapsed sampling time) were not observed in the current project (p<0.05). Also, approximately 16% of Sarasota Bay bottlenose dolphin aldosterone concentrations were below the assay's detection limit (11 pg/mL), thus hindering the ability to derive 95th percentile RIs. Serum aldosterone concentrations from animals sampled at the three additional sites were compared to the detection limit, and the proportion of animals with low aldosterone concentrations was not significantly different than an expected prevalence of 16%. Although this study relied upon long-term, free-ranging bottlenose dolphin health data from a single site, the objective RIs can be used for future evaluation of adrenal function among individuals sampled during capture-release health assessments.
Salivary Iron (Fe) Ion Levels, Serum Markers of Anemia and Caries Activity in Pregnant Women.
Costa, Elisa Miranda; Azevedo, Juliana Aires Paiva de; Martins, Rafiza Félix Marão; Rodrigues, Vandilson Pereira; Alves, Cláudia Maria Coêlho; Ribeiro, Cecília Cláudia Costa; Thomaz, Erika Bárbara Abreu Fonseca
2017-03-01
Introduction Anemia is a very frequent event among pregnant women. There are evidences of differences in the incidence of dental caries between pregnant and non-pregnant women, but the relationship between salivary iron (Fe) and serum markers of anemia and caries development has not been investigated. Objective To evaluate the correlation between salivary (Fe) and serum iron (Fe, ferritin and hemoglobin) parameters in pregnant women with the development of dental caries. Methods A prospective cohort was conducted with 59 women. The outcome of interest was represented by new dental caries lesions during pregnancy, using the Nyvad criteria. Pregnant women were evaluated at three clinical times: up to the 16th week of gestational age (GA) (T1), in the last trimester of pregnancy (T2), and postpartum (T3), at the Mother and Child Unit of University Hospital of the Universidade Federal do Maranhão. A stimulated saliva sample was collected for biochemical analysis of salivary Fe, and a blood sample was collected early in the morning. The correlation between salivary and serum Fe was evaluated through the Pearson correlation test. Analysis of variance (ANOVA) and Kruskal-Wallis were used to compare the means of anemia parameters at different times. The Student's t and Mann-Whitney tests were used to compare the anemia parameters between the groups of pregnant women (with and without new caries lesions). Results Serum Fe concentrations were higher in the first trimester of pregnancy and lower after delivery ( p = 0.036). It was also observed that the ferritin concentrations were higher in the first trimester and lower at the end of gestation ( p = 0.011). There was no association between the expositions of salivary iron and anemia, and the development of dental caries. There was a positive correlation between serum Fe in T1 and salivary Fe in T2 ( p < 0.05). Conclusion The serum markers of anemia were more prevalent in the last trimester of pregnancy. Thieme-Revinter Publicações Ltda Rio de Janeiro, Brazil.
Cury, Didia Bismara; Mizsputen, Sender Jankiel; Versolato, Clara; Miiji, Luciana Odashiro; Pereira, Edson; Delboni, Maria Aparecida; Schor, Nestor; Moss, Alan C.
2014-01-01
Background and aim Serum calprotectin is elevated in patients with inflammatory bowel disease (IBD). Whether it correlates other markers of disease activity is unknown. The aim of this study was to correlate serum calprotectin with biochemical and histological measures of intestinal inflammation. Materials and methods TNBS colitis was induced in wistar rats, and serial blood samples were collected at 0, 3, and 12 days. Animals were subsequently sacrificed for pathological evaluation at day 12. Serum calprotectin and cytokines were measured by ELISA. Pathologic changes were classified at the macroscopic and microscopic levels. Results TNBS colitis induced elevated serum calprotectin, TNF and IL-6 within 24 h. Levels of serum calprotectin remained elevated in parallel to persistence of loose stool and weight loss to day 12. Serum calprotectin levels correlated with serum levels of TNF-α and IL6 (p < 0.001), but not CRP. Animals with liquid stool had significantly higher levels of serum calprotectin than control animals. There was a correlation between macroscopic colitis scores, and levels of serum calprotectin. Conclusion Serum calprotectin levels correlate with biochemical and histological markers of inflammation in TNBS colitis. This biomarker may have potential for diagnostic use in patients with IBD. PMID:23685388
el-Zoghbi, M; Sitohy, M Z
2001-04-01
Male albino rats were fed diets contained 6.85% mineral salts for 2 weeks (adaptation condition). Then they were fed the dietary pectin administered diet for 6 weeks to evaluate the effect of administration of pectin on the absorption of some monovalent, bivalent and heavy metals in the serum of rats. The experimental parameters included, monovalent minerals (K, Na), bivalent minerals (Zn, Cu, Ca, Fe), heavy metals (Pb, Cd), serum uric acid and serum creatinine. The obtained results indicated that the serum contents of monovalent minerals were negatively affected by pectin administration. The low degree of esterification of pectin was more effective on the absorption of bivalent minerals. Also, the rat serum levels of lead and cadmium were reduced by pectin administration. Serum total proteins were reduced by pectin administration. The level of rat serum of uric acid and creatinine fed different sources of pectin were within normal levels and were insignificantly lower than that recorded for control samples.
Seo, Bong-Kyung; Kim, Nam-Eun; Park, Kyong-Min; Park, Kye-Yeung; Park, Hoon-Ki
2017-01-01
Background The purpose of this study was to evaluate serum lipid levels in Korean adults after consumption of different types of yogurt. Methods Study subjects were 3,038 individuals (≥19 years of age) who participated in the 2012 Korean National Health and Nutrition Examination Survey. Yogurt intake was assessed with a food frequency questionnaire by using the 24-hour recall method. We conducted complex samples general linear analysis with adjustment for covariates. Results The serum triglyceride levels in the group consuming viscous yogurt were lower than those in the group consuming non-viscous yogurt. Conclusion Consumption of viscous yogurt is associated with low serum triglyceride levels in Korean adults. PMID:29026484
Pape, B E; Cary, P L; Clay, L C; Godolphin, W
1983-01-01
Pentobarbital serum concentrations associated with a high-dose therapeutic regimen were determined using EMIT immunoassay reagents. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of 5.0% and a between-assay coefficient of variation of 10%. Regression analysis of 44 serum samples analyzed by this technique (y) and a reference procedure (x) were y = 0.98x + 3.6 (r = 0.98; x = ultraviolet spectroscopy) and y = 1.04x + 2.4 (r = 0.96; x = high-performance liquid chromatography). Clinical evaluation of the results indicates the immunoassay is sufficiently sensitive and selective for pentobarbital to allow accurate quantitation within the therapeutic range associated with high-dose therapy.
Serial serum alkaline phosphatase as an early biomarker for osteopenia of prematurity.
Abdallah, Enas A A; Said, Reem N; Mosallam, Dalia S; Moawad, Eman M I; Kamal, Naglaa M; Fathallah, Mohammed G E-D
2016-09-01
Metabolic bone disease of prematurity is a condition characterized by reduction in bone mineral content (osteopenia). It is a problem faced by very low birth weight (VLBW) infants because of lack of fetal mineralization during the last trimester. Our aim was to assess serum alkaline phosphatase (ALP) level as an early biomarker for osteopenia in premature infants and to estimate an optimal cutoff value of serum ALP at which osteopenia is detected radiologically in premature newborns.This prospective study was conducted on a cohort of 120 newborn infants of both sex of ≤34 weeks' gestational age and <1500 g birth weight. Two blood samples, from each infant on at least 2 consecutive weeks, were reported for calcium, phosphorus, and ALP. Evidence of osteopenia was evaluated radiologically by performing wrist/knee x-ray.Sixteen infants (13.3%) had evidence of osteopenia in x-ray, whereas 104 infants (86.7%) were nonosteopenic and all the osteopenic infants were <1000-g birth weight. Birth weight and gestational age were significantly inversely related to serum ALP levels. Both samples showed statistically significantly higher mean ALP level in osteopenic than nonosteopenics (P < 0.001, and P < 0.001 respectively). There was no constant value of serum ALP related to radiologic evidence of osteopenia. However, the optimal cutoff value of serum ALP at which osteopenia is detected is 500 IU/L with 100% sensitivity and 80.77% specificity.High levels of ALP can be considered a reliable biomarker to predict the status of bone mineralization and the need for radiological evaluation in premature infants particularly those <1000-g birth weight and <32 weeks' gestation.
Shirmohamadi, Adileh; Chitsazi, Mohamad Taghi; Faramarzi, Masoumeh; Salari, Ashkan; Naser Alavi, Fereshteh; Pashazadeh, Nazila
2016-01-01
Background. Transferrin is a negative acute phase protein, which decreases during inflammation and infection. The aim of the present investigation was to evaluate changes in the transferrin serum levels subsequent to non-surgical treatment of chronic periodontal disease. Methods. Twenty patients with chronic periodontitis and 20 systemically healthy subjects without periodontal disease, who had referred to Tabriz Faculty of Dentistry, were selected. Transferrin serum levels and clinical periodontal parameters (pocket depth, clinical attachment level, gingival index, bleeding index and plaque index) were measured at baseline and 3 months after non-surgical periodontal treatment. Data were analyzed with descriptive statistical methods (means ± standard deviations). Independent samples t-test was used to compare transferrin serum levels and clinical variables between the test and control groups. Paired samples t-test was used in the test group for comparisons before and after treatment. Statistical significance was set at P < 0.05. Results. The mean transferrin serum level in patients with chronic periodontitis (213.1 ± 9.2 mg/dL) was significantly less than that in periodontally healthy subjects (307.8 ± 11.7 mg/dL). Three months after periodontal treatment, the transferrin serum level increased significantly (298.3 ± 7.6 mg/dL) and approached the levels in periodontally healthy subjects (P < 0.05). Conclusion. The decrease and increase in transferrin serum levels with periodontal disease and periodontal treatment, respectively, indicated an inverse relationship between transferrin serum levels and chronic periodontitis. PMID:27651883
Measurement of salivary adiponectin concentrations in dogs.
Tvarijonaviciute, Asta; Carrillo-Sanchez, Juana D; García-Martinez, Juan D; Tecles, Fernando; Martinez-Subiela, Silvia; German, Alexander J; Ceron, Jose J
2014-09-01
Measurement of salivary adiponectin could improve understanding of this adipokine's physiology, and its role in various clinical conditions. The purpose of the study was to evaluate the utility of a human adiponectin ELISA kit for measurement of salivary adiponectin in dogs, to compare serum and salivary adiponectin concentrations in a healthy dog population, and to evaluate possible effects of tooth-cleaning on serum and salivary adiponectin concentrations in dogs. For analytical validation, precision, accuracy, and lower limit of quantification of the assay were determined with saliva samples. In addition, adiponectin concentrations were quantified in serum and saliva samples from 24 healthy dogs, and from 7 dogs with mild gingivitis before and after a tooth-cleaning procedure. The validation assays for salivary adiponectin had all coefficients of variation <15%, and recovery ranged from 85% to 120%. In the linearity test, interference was observed when measuring adiponectin in saliva, but this was solved by diluting samples 1:4. In healthy dogs, salivary and serum adiponectin concentrations were positively correlated (r = .650; P = .009). After the tooth-cleaning procedure, salivary adiponectin concentration increased on day 0 (P = .004), but by day 14, concentrations were less than prior to the procedure (P = .041). The human adiponectin ELISA kit can be used for precise and accurate salivary adiponectin measurement in dogs. Salivary adiponectin increased 24 hours after tooth-cleaning, possibly due to acute inflammation or adiponectin leakage from the blood after gingival trauma. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Javanbakht, Mehran; Namjumanesh, Mohammad Hadi; Akbari-Adergani, Behrouz
2009-11-15
In this work, a novel method is described for the determination of bromhexine in biological fluids using molecularly imprinted solid-phase extraction as the sample cleanup technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and bromhexine as the template molecule. The novel imprinted polymer was used as a solid-phase extraction sorbent for the extraction of bromhexine from human serum and urine. Various parameters affecting the extraction efficiency of the polymer have been evaluated. The optimal conditions for molecularly imprinted solid-phase extraction (MISPE) consisted of conditioning 1 mL methanol and 1 mL of deionized water at neutral pH, loading of 5 mL of the water sample (25 microg L(-1)) at pH 6.0, washing using 2 mL acetonitrile/acetone (1/4, v/v) and elution with 3x 1 mL methanol/acetic acid (10/1, v/v). The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of bromhexine. Results from the HPLC analyses showed that the calibration curve of bromhexine using MIP from human serum and urine is linear in the ranges of 0.5-100 and 1.5-100 microg L(-1) with good precisions (3.3% and 2.8% for 5.0 microg L(-1)), respectively. The recoveries for serum and urine samples were higher than 92%.
9 CFR 147.7 - Standard test procedures for mycoplasma. 5
Code of Federal Regulations, 2011 CFR
2011-01-01
... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...
9 CFR 147.7 - Standard test procedures for mycoplasma. 5
Code of Federal Regulations, 2012 CFR
2012-01-01
... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...
9 CFR 147.7 - Standard test procedures for mycoplasma. 5
Code of Federal Regulations, 2010 CFR
2010-01-01
... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...
9 CFR 147.7 - Standard test procedures for mycoplasma. 5
Code of Federal Regulations, 2014 CFR
2014-01-01
... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...
9 CFR 147.7 - Standard test procedures for mycoplasma. 5
Code of Federal Regulations, 2013 CFR
2013-01-01
... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...
Israeli, E; Grotto, I; Gilburd, B; Balicer, R D; Goldin, E; Wiik, A; Shoenfeld, Y
2005-09-01
Several antibodies have been reported in the sera of patients with Crohn's disease (CD) and ulcerative colitis (UC). The most commonly described are anti-Saccharomyces cerevisiae mannan antibodies (ASCA) in CD and perinuclear antineutrophil cytoplasm antibodies (pANCA) in UC. Familial clustering of these antibodies has been described, suggesting they might be genetic markers. Our aim was to investigate the presence of these antibodies before the emergence of overt clinical manifestations. Since 1980, the Israeli Defense Force (IDF) Medical Corps Serum Repository has stored serum samples obtained systematically from 5% of all recruits on enlistment, and from the same population on discharge from compulsory military service. We evaluated serum samples obtained from 32 subjects with CD and eight with UC before they were clinically diagnosed, along with samples from matched controls. ASCA were present in 10/32 (31.3%) CD patients before clinical diagnosis compared with 0/95 (0%) controls (p<0.001). None of the eight patients with serum samples available before diagnosis of UC were ASCA positive. ASCA was positive in 54.5% of patients after diagnosis of CD. The mean interval between ASCA detection and diagnosis was 38 months. In 90% of patients, antibodies were detected in the first available serum sample; therefore, measurements of the average time from the presence of ASCA to diagnosis may be even longer. pANCA were present in 2/8 (25%) patients with available sera before the diagnosis of UC. None of their 24 matched controls were positive (p = 0.014). ASCA and pANCA may predict development of inflammatory bowel disease years before the disease is clinically diagnosed.
Evaluation of ID-PaGIA syphilis antibody test.
Naaber, Paul; Makoid, Ene; Aus, Anneli; Loivukene, Krista; Poder, Airi
2009-01-01
Laboratory diagnosis of syphilis is usually accomplished by serology. There are currently a large number of different commercial treponemal tests available that vary in format, sensitivity and specificity. To evaluate the ID-PaGIA Syphilis Antibody Test as an alternative to other specific treponemal tests for primary screening or confirmation of diagnosis. Serum samples from healthy adults (n = 100) were used for detection of specificity of ID-PaGIA. To evaluate sensitivity of ID-PaGIA serum samples (n = 101) from patients with confirmed or suspected syphilis were tested for syphilis antibodies with FTA-Abs IgM, ID-PaGIA, ELISA IgM and TPHA tests. No false-positive results were found with ID-PaGIA. Sensitivity of various treponemal tests was the following: FTA-Abs IgM: 95.5%, ID-PaGIA and ELISA IgM: 94%, and TPHA 75%. The positive and negative predictive values of ID-PaGIA were 100 and 89.5%, respectively. Compared with other treponemal tests ID-PaGIA has excellent sensitivity and specificity.
Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun
2014-02-01
Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from
Serum protein electrophoretic pattern in one-humped camels (Camelus dromedarius) in Tripoli, Libya.
Abdoslam, Omran; Bayt-Almal, Mahmoud; Almghrbe, Abdullah; Algriany, Omran
2018-01-01
The aim of this study was to characterize serum protein capillary electrophoretic pattern in apparently healthy adult male (age: 3-7 years) dromedary camels and also evaluate total protein and albumin levels using automated analyzer. Blood samples were taken from 20 camels. 5ml of blood was collected from the jugular vein and serum was separated from samples by centrifugation. Capillary electrophoresis of serum proteins identified six protein fractions in adult camels, including albumin, alpha1, alpha2, beta1, beta2 and gamma globulins, serum levels of these parameters were 3.9±0.04 g/dl, 0.16±0.01 g/dl, 0.39±0.03 g/dl, 0.515±0.03 g/dl, 0.205±0.01 g/dl and 0.61±0.04 g/dl, and 65.42±0.62 g/l, respectively. The total protein concentration was 65.42±0.62 g/L, while, the albumin/globulin (A/G) ratio was 2.4±0.14. The present study indicates six peaks with minicapillary electrophoresis and the results obtained were compared and interpreted in the light of finding reported by other investigators in camels.
Yue, Chao-Yan; Ying, Chun-Mei
2017-01-01
To explore the effect of modified enzyme-linked immunosorbent assay on the AMH results is increased or decreased, and to investigate the effect of storage time and temperature on AMH measurements with and without sample premixing assay buffer using the Kangrun ELISA method. Serum AMH concentration were measured by ELISA, consistency between two kits, and comparability between original and the modified assay under different stored conditions were analyzed by Passing-Bablok regression analysis and Bland-Altman bias evaluation. There was a strong consistency between AMH concentrations measured in Kangrun ELISA and Ansh Labs ultra-sensitive AMH ELISA. Pre-mixing serum specimens with assay buffer gave consistent results compared with original assay. Modified protocol can reduce the amplitude of increase affected by sample aged and give the most consistent results regardless of storage conditions. Pre-mixing protocol did not influence the results of fresh serum or frozen serum incubation <3days at 4°C and -80°C, but when specimens detected after collection and stored in other storage conditions, should be pre-mixed with assay buffer to insure its accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.
Grützner, Niels; Suchodolski, Jan S; Steiner, Jörg M
2014-12-01
Increased serum concentrations of homocysteine (HCY) and methylmalonic acid (MMA), the 2 main cobalamin-dependent metabolites, as well as decreased serum albumin and canine alpha1 -proteinase inhibitor (cα1 -PI) concentrations have previously been described in hypocobalaminemic dogs with gastrointestinal disease. However, no studies have been conducted to evaluate potential relationships between these serum biomarkers. The aim of this study was to evaluate the relationship between HCY and MMA, 2 cobalamin-dependent metabolites, and both serum albumin and cα1 -PI concentrations in hypocobalaminemic dogs. Serum samples from 285 dogs including 7 different breeds (Beagle, Boxer, Cocker Spaniel, German Shepherd, Labrador Retriever, Chinese Shar-Pei, and Yorkshire Terrier) with hypocobalaminemia were used. Serum HCY, MMA, albumin, and cα1 -PI concentrations were determined. There was a significant correlation between serum HCY and albumin concentrations, as well as serum HCY and cα1 -PI concentrations (ρ = 0.62 and ρ = 0.37, respectively; P < .0001). No correlations were observed between serum MMA and albumin concentrations, or cα1 -PI concentrations (ρ = 0.01 and ρ = 0.08, respectively; P > .05). In addition, significant breed-specific correlations were observed between serum MMA and albumin concentrations in German Shepherds, and serum HCY and MMA concentrations in Chinese Shar-Peis with hypocobalaminemia. This study shows a correlation between serum albumin and cα1 -PI and HCY concentrations, but not with serum MMA concentration in dogs with hypocobalaminemia. In addition, significant breed-specific correlations were observed between serum MMA and albumin concentrations in German Shepherds, as well as serum HCY and MMA concentrations in Chinese Shar-Peis, emphasizing the unique metabolic interactions in those dog breeds affected by hypocobalaminemia. © 2014 American Society for Veterinary Clinical Pathology.
Wang, Jiaojiao; Lan, Jingfeng; Li, Huihui; Liu, Xiaoyan; Zhang, Haixia
2017-01-01
In proteomic studies, poor detection of low abundant proteins is a major problem due to the presence of highly abundant proteins. Therefore, the specific removal or depletion of highly abundant proteins prior to analysis is necessary. In response to this problem, a series of pH-sensitive functional mesoporous silica materials composed of 2-(diethylamino)ethyl methacrylate and methacrylic acid units were designed and synthesized via atom transfer radical polymerization. These functional mesoporous silica materials were characterized and their ability for adsorption and separation of proteins was evaluated. Possessing a pH-sensitive feature, the synthesized functional materials showed selective adsorption of some proteins in aqueous or buffer solutions at certain pH values. The specific removal of a particular protein from a mixed protein solution was subsequently studied. The analytical results confirmed that all the target proteins (bovine serum albumin, ovalbumin, and lysozyme) can be removed by the proposed materials from a five-protein mixture in a single operation. Finally, the practical application of this approach was also evaluated by the selective removal of certain proteins from real biological samples. The results revealed that the maximum removal efficiencies of ovalbumin and lysozyme from egg white sample were obtained as 99% and 92%, respectively, while the maximum removal efficiency of human serum albumin from human serum sample was about 80% by the proposed method. It suggested that this treatment process reduced the complexity of real biological samples and facilitated the identification of hidden proteins in chromatograms. Copyright © 2016 Elsevier B.V. All rights reserved.
Burtis, C.A.; Johnson, W.F.; Walker, W.A.
1985-08-05
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
Biomonitoring data can help inform the development and calibration of high-throughput exposure modeling for use in prioritization and risk evaluation. A pilot project was conducted to evaluate the feasibility of using pooled banked blood samples to generate initial data on popul...
Srinivasan, Balaji; O'Dell, Dakota; Finkelstein, Julia L; Lee, Seoho; Erickson, David; Mehta, Saurabh
2018-01-15
Iron deficiency (ID) is an urgent public health problem that has devastating effects on maternal and child health. However, due to poor access and affordability, screening and diagnosis for ID is often limited to proxy hemoglobin measurements alone. Here, we report the development and validation of ironPhone, a mobile-device coupled portable diagnostics for quantification of serum ferritin concentrations, an iron status biomarker, within a few minutes, from a drop of fingerprick blood. The ironPhone diagnostic platform comprises of a smartphone accessory, an app, and a disposable lateral flow immunoassay test strip to quantify serum ferritin. For initial validation in the lab, we optimized and evaluated the performance of ironPhone with known ferritin concentrations in spiked buffer and serum samples. Following lab validation, we performed a human validation by collecting fingerprick whole blood samples from 20 participants to assess iron status using ironPhone and compared the results with the laboratory standard IMMULITE 2000 analyzer. Findings from the ironPhone for the buffer and spiked serum samples provided a calibration curve with R 2 values of 0.97 (n=27) and 0.93 (n=12), respectively. On comparison with the laboratory standard IMMULITE analyzer in whole blood samples, a correlation of 0.92 (P<0.0001) was observed with a sensitivity of over 90% for predicting ID (ferritin<15.0µg/L) via the ironPhone, demonstrating its promise for iron status assessment at the point-of-care. Copyright © 2017 Elsevier B.V. All rights reserved.
Reference measurement procedure for total glycerides by isotope dilution GC-MS.
Edwards, Selvin H; Stribling, Shelton L; Pyatt, Susan D; Kimberly, Mary M
2012-04-01
The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum. We diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [(13)C(3)]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b). The calibration response was linear for the range of calibrator concentrations examined (0-1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123-0.7225) and 0.3122 (95% CI, 0.3096-0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%. This ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.
Bagchus, Wilma M; Smeets, Jean M W; Verheul, Herman A M; De Jager-Van Der Veen, Suzanne M; Port, Andreas; Geurts, T B Paul
2005-05-01
The pharmacokinetics of nandrolone in serum and urine were investigated in healthy young men after a single im injection of 50 mg (n = 20), 100 mg (n = 17), or 150 mg (n = 17) nandrolone decanoate. Blood samples were collected before treatment and for up to 32 d after dosing. In addition, in the 50- and 150-mg groups, 24-h urine samples were collected before treatment and on d 1, 7, and 33 after treatment; in the 150-mg group, additional samples were collected after 3 and 6 months. Serum concentrations and the area under the curve of nandrolone increased proportionally with the dose administered. The peak serum concentration ranged from 2.14 ng/ml in the 50-mg group to 4.26 ng/ml in the 100-mg group and 5.16 ng/ml in the 150-mg group. The peak serum concentration was reached after 30 h (50 and 100 mg) and 72 h (150 mg), whereas the terminal half-life was 7-12 d. In urine, pretreatment concentrations of 19-norandrosterone (19-NA) and/or 19-noretiocholanolone (19-NE) were detected in five of 37 subjects (14%). In the 50-mg group, 19-NA and/or 19-NE could be detected at least until 33 d after injection in 16 of 17 subjects (94%). In the 150-mg group, who were presumed to have not previously used nandrolone, nandrolone metabolites could be detected for up to 6 months in eight of 12 subjects (67%) for 19-NE and in 10 of 12 subjects (83%) for 19-NA.
Müller, A; Freude, B
2016-01-01
An optimal selenium supply of cattle is essential, because an insufficiency can lead to health disorders and reduced performance. The aim of the study was to retrospectively evaluate the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Serum samples from 45 068 cattle with unknown clinical status originating from countries all across Europe, which had been sent by veterinarians to the IDEXX Laboratory Ludwigsburg, Germany, between January 1st, 2006 and June 30th, 2015, were routinely analyzed for the selenium concentration by means of Inductively Coupled Plasma Mass Spectrometry. A total of 40 949 samples (30 462 from Germany, 4004 from Austria, 3232 from Switzerland, 3251 from Denmark) were included in the evaluation. Results were categorized as follows: 50-150 µg/l: sufficient supply, < 50 µg/l: supply too low, > 150 µg/l: supply too high. During the observation period, a generalized trend towards a decreasing selenium supply was clear. Denmark showed the best selenium supply (77.4% of samples indicating a sufficient supply); however, even in this country a tendency towards a deterioration was seen. A very poor situation with a strongly decreasing selenium supply was observed in Austria, followed by Germany (38% and 30% of samples, respectively, indicating an undersupply). For Switzerland, a constantly poor selenium supply was found (49% of samples indicating an undersupply). Due to the ongoing trend of a selenium undersupply in cattle herds, it is recommended to control the serum selenium concentration annually and supplement this trace element via mineral food when necessary.
2012-01-01
Background Systemic hypertension is a prominent feature in humans with metabolic syndrome (MS) and this is partly caused by an enhanced endothelin-1 (ET-1) mediated vasoconstriction. There are indications that systemic hypertension might be a feature in equine metabolic syndrome (EMS) but if ET-1 is involved in the development of hypertension in horses is not known. Increased levels of cortisol have also been found in humans with MS but there are no reports of this in horses. Before blood pressure, plasma ET-1 and serum cortisol can be evaluated in horses with EMS, it is necessary to investigate the interday variation of these parameters on clinically healthy horses. The aims of the present study were therefore to evaluate the interday variation and influence of transportation on systemic blood pressure, plasma ET-1 and serum cortisol in healthy Standardbred and Icelandic horses, and to detect potential breed differences. Methods Nine horses of each breed were included in the study. Blood pressure was measured and blood samples were collected between 6 and 9 am on two separate days. Eight of the horses (four of each breed) were transported to a new stable were they stayed overnight. The next morning, the sampling procedure was repeated. Results The interday variation was higher for plasma ET-1 (37%) than for indirect pressure measurements (8-21%) and serum cortisol (18%). There were no differences in systemic blood pressure between the two breeds. The Icelandic horses had significantly lower serum cortisol and significantly higher plasma ET-1 concentrations compared to the Standardbred horses. Plasma ET-1 was significantly elevated after transportation, but systemic blood pressure and serum cortisol did not differ from the values obtained in the home environment. Conclusions Indirect blood pressure, plasma ET-1 and serum cortisol are of interest as markers for cardiovascular dysfunction in horses with EMS. The elevated plasma ET-1 concentrations recorded after transportation was likely caused by a stress response. This needs to be considered when evaluating plasma ET-1 in horses after transportation. The differences detected in plasma ET-1 and serum cortisol between the two breeds might be related to differences in genetic setup, training status as well as management conditions. PMID:22682151
High VEGF-D and Low MMP-2 Serum Levels Predict Nodal-Positive Disease in Invasive Bladder Cancer
Benoit, Tobias; Keller, Etienne X.; Wolfsgruber, Pirmin; Hermanns, Thomas; Günthart, Michele; Banzola, Irina; Sulser, Tullio; Provenzano, Maurizio; Poyet, Cédric
2015-01-01
Background To investigate stromal variables including angiogenesis, lymphangiogenesis, and matrix metalloproteinase (MMP) in the serum of patients with urothelial carcinoma of the bladder (UCB) and to evaluate their association with histopathological characteristics and clinical outcome. Material/Methods Protein levels of vascular endothelial growth factors-A, -C, -D (VEGF-A/-C/-D), their receptors- VEGF-R2 and -R3 (VEGF-R2/-R3), and matrix metalloproteinases 2, -3, and -7 (MMP-2, MMP-3, MMP-7) were quantified in the blood serum samples of 71 patients with UCB before radical cystectomy (RC). Samples of patients with non-invasive UCB or no history of UCB were investigated as controls (n=20). Protein levels in the serum were measured using a flow cytometric cytokine assay. Results A positive association for VEGF-D (p<0.001) and an inverse association for MMP-2 (p=0.017) were observed in patients with positive lymph node (LN) status at the time of RC. VEGF-A (p<0.001), VEGF-C (p<0.001), MMP-2 (p<0.001), and MMP-7 (p=0.005) serum levels were different in serum of patients with invasive UCB compared with non-invasive UCB or healthy individuals. None of the serum markers were associated with disease progression. Conclusions High VEGF-D and low MMP-2 serum levels predict LN metastasis in patients with UCB at the time of RC. VEGF-A, VEGF-C, MMP-2, and MMP-7 serum levels varied significantly between invasive and non-invasive disease as well as in comparison with healthy individuals. Clinical implementation of these marker serum measurements may be valuable to select high-risk patients with more invasive or nodal-positive disease. PMID:26241709
Worley, Rachel Rogers; Moore, Susan McAfee; Tierney, Bruce C; Ye, Xiaoyun; Calafat, Antonia M; Campbell, Sean; Woudneh, Million B; Fisher, Jeffrey
2017-09-01
Per- and polyfluoroalkyl substances (PFAS) are considered chemicals of emerging concern, in part due to their environmental and biological persistence and the potential for widespread human exposure. In 2007, a PFAS manufacturer near Decatur, Alabama notified the United States Environmental Protection Agency (EPA) it had discharged PFAS into a wastewater treatment plant, resulting in environmental contamination and potential exposures to the local community. To characterize PFAS exposure over time, the Agency for Toxic Substances and Disease Registry (ATSDR) collected blood and urine samples from local residents. Eight PFAS were measured in serum in 2010 (n=153). Eleven PFAS were measured in serum, and five PFAS were measured in urine (n=45) from some of the same residents in 2016. Serum concentrations were compared to nationally representative data and change in serum concentration over time was evaluated. Biological half-lives were estimated for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS) using a one-compartment pharmacokinetic model. In 2010 and 2016, geometric mean PFOA and PFOS serum concentrations were elevated in participants compared to the general U.S. In 2016, the geometric mean PFHxS serum concentration was elevated compared to the general U.S. Geometric mean serum concentrations of PFOA, PFOS, and perfluorononanoic acid (PFNA) were significantly (p≤0.0001) lower (49%, 53%, and 58%, respectively) in 2016 compared to 2010. Half-lives for PFOA, PFOS, and PFHxS were estimated to be 3.9, 3.3, and 15.5years, respectively. Concentrations of PFOA in serum and urine were highly correlated (r=0.75) in males. Serum concentrations of some PFAS are decreasing in this residentially exposed community, but remain elevated compared to the U.S. general population. Published by Elsevier Ltd.
Piñeiro, Matilde; Morales, Joaquín; Vizcaíno, Elena; Murillo, José Alberto; Klauke, Thorsten; Petersen, Brigitte; Piñeiro, Carlos
2013-11-01
The serum concentration of acute phase proteins (APPs) increases in the presence of disease or stress, which makes APPs notable parameters for the global assessment of animal health and welfare. A rapid, immunochromatographic test (ICT) for the detection of elevated levels of pig Major Acute-phase Protein (pig-MAP), one of the main APPs in pigs, was evaluated in more than 1400 pig serum samples obtained from commercial farms. The ICT showed a good performance with a relative sensitivity (Sn) and specificity (Sp) of 94 and 97%, respectively, for a threshold of 1.5mg/mL (comparison with ELISA). Differences in the pig-MAP levels and the number of positive samples with the ICT were observed within the season of sampling, farms, and age groups at one farm, according to the presence of disease or lesions. The ICT was also evaluated in blood samples obtained at slaughter in association with the carcase inspection. The results from this study indicate that the ICT may be used for the evaluation of groups of pigs, after analysing one sub-sample of these pigs, and might be a useful tool in routine health and welfare monitoring programmes aimed to improve the quality of pig production. Copyright © 2013 Elsevier Ltd. All rights reserved.
[Serum glycosaminoglycans in Graves' disease patients].
Winsz-Szczotka, Katarzyna B; Olczyk, Krystyna Z; Koźma, Ewa M; Komosińska-Vassev, Katarzyna B; Wisowski, Grzegorz R; Marcisz, Czesław
2006-01-01
The aim of the study was to determine the blood serum sulfated glycosaminoglycans (GAGs) and hyaluronic acid (HA) concentration of Graves' disease patients before treatment and after attainment of the euthyroid state. The study was carried out on the blood serum obtained from 17 patients with newly recognised Graves' disease and from the same patients after attainment of the euthyroid state. Graves' patients had not any clinical symptoms neither of ophthalmopathy nor pretibial myxedema. GAGs were isolated from the blood serum by the multistage extraction and purification using papaine hydrolysis, alkali elimination, as well as cetylpyridium chloride binding. Total amount of GAGs was quantified by the hexuronic acids assay. HA content in obtained GAGs sample was evaluated by the ELISA method. Increased serum concentration of sulfated GAGs in non-treated Graves' disease patients was found. Similarly, serum HA level in untreated patients was significantly elevated. The attainment of euthyroid state was accompanied by the decreased serum sulfated GAGs level and by normalization of serum HA concentration. In conclusion, the results obtained demonstrate that the alterations of GAGs metabolism connected with Graves' disease can lead to systemic changes of the extracellular matrix properties.
Blood-collection device for trace and ultra-trace metal specimens evaluated.
Moyer, T P; Mussmann, G V; Nixon, D E
1991-05-01
We evaluated the evacuated phlebotomy tube designed specifically for trace metal analysis by Sherwood Medical Co. Pools of human serum containing known concentrations of aluminum, arsenic, calcium, cadmium, copper, chromium, iron, lead, magnesium, manganese, mercury, selenium, and zinc were exposed to the tube and rubber stopper for defined periods ranging from 5 min to 24 h. Analysis for each element was performed in a randomized fashion under rigidly controlled conditions by use of standard electrothermal atomization atomic absorption spectroscopy, inductively coupled plasma atomic emission spectroscopy, and cold vapor atomic absorption spectrometry. In addition, for comparative purposes, we collected blood samples from normal volunteers by use of ultra-clean polystyrene phlebotomy syringes as well as standard evacuated phlebotomy tubes. We conclude that, except for lead, there was no significant contribution of any trace element studied from the evaluated tube and stopper to the serum. Because whole blood is the usual specimen for lead testing, the observation of a trace amount of lead in this tube designed for serum collection is trivial.
Serum TIMP1 and TIMP2 concentration in patients with different grades of meningioma.
Mashayekhi, Farhad; Saberi, Alia; Mashayekhi, Sohail
2018-07-01
Meningiomas are common primary brain tumors that constitute about 13% of all intracranial tumors. Matrix metalloproteinase-9 (MMP-9) is able to degrade the extracellular matrix and basement membrane leading to cancer cell invasion and metastasis. MMPs are specifically inhibited by a family of small extracellular proteins known as the tissue inhibitors of metalloproteinases (TIMPs). The objective of this project was to evaluate serum concentration of TIMP-1 and TIMP-2 in patients with different grades of meningioma. Ninety samples from different stages of patients with meningitis (42 cases of grade I, 28 grade II, 20 grade III) and 51 samples from normal healthy were included in this study. Total protein concentration (TPC) and the level TIMP-1 and TIMP-2 serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay (ELISA), respectively. No significant change in the TPC was seen in the serum of patients with meningioma when compared with normal controls. Results obtained demonstrated that all serum samples presented TIMP-1 and TIMP-2 expression, whereas, starting from grade I to III meningiomas, a significant decrease of TIMP-1 and TIMP-2 expression was observed as compared to controls. The results of this study show that a low expression of TIMP1 and TIMP2 is correlated with advanced stages of meningioma. It is also concluded that the detection of serum TIMP1 and TIMP2 may be useful in classifying different grades of meningioma. Copyright © 2018 Elsevier B.V. All rights reserved.
Evidence to support a contribution of polyreactive antibodies to HLA serum reactivity
Gao, Baoshan; Rong, Chunshu; Porcheray, Fabrice; Moore, Carolina; Girouard, Timothy C.; Saidman, Susan L.; Wong, Waichi; Fu, Yaowen; Zorn, Emmanuel
2015-01-01
Background Assessing the serum reactivity to HLA is essential for the evaluation of transplant candidates and the follow-up of allograft recipients. In this study, we look for evidence at the clonal level that polyreactive antibodies cross-reactive to apoptotic cells and multiple autoantigens can also react to HLA and contribute to the overall serum reactivity. Methods We immortalized B cell clones from the blood of two kidney transplant recipients and characterized their reactivity to self-antigens, apoptotic cells as well as native, denatured and cryptic HLA determinants using ELISA, immunofluorescence, flow cytometry and Luminex assays. We also assessed the reactivity of 300 pre-transplant serum specimens to HLA and apoptotic cells. Results We report here 4 distinct B cell clones cross-reactive to self and HLA class I. All 4 clones reacted to numerous HLA class I alleles but did not appear to target canonical “shared” epitopes. In parallel experiments, we observed a strong correlation between IgG reactivity to HLA and apoptotic cells in pre-transplant serum samples collected from 300 kidney transplant recipients. Further analysis revealed that samples with higher reactivity to apoptotic cells displayed significantly higher class I percent PRA compared to samples with low reactivity to apoptotic cells. Conclusions We provide here 1) proof of principle at the clonal level that human polyreactive antibodies can cross-react to HLA, multiple self-antigens and apoptotic cells and 2) supportive evidence that polyreactive antibodies contribute to overall HLA reactivity in the serum of patients awaiting kidney transplant. PMID:26285015
Kittawornrat, Apisit; Panyasing, Yaowalak; Goodell, Christa; Wang, Chong; Gauger, Phillip; Harmon, Karen; Rauh, Rolf; Desfresne, Luc; Levis, Ian; Zimmerman, Jeffrey
2014-01-31
Oral fluid samples collected from litters of piglets (n=600) one day prior to weaning were evaluated as a method to surveil for porcine reproductive and respiratory syndrome virus (PRRSV) infections in four sow herds of approximately 12,500 sow each. Serum samples from the litters' dam (n=600) were included for comparison. All four herds were endemically infected with PRRSV and all sows had been vaccinated ≥ 2 times with PRRSV modified-live virus vaccines. After all specimens had been collected, samples were randomized and assayed by PRRSV real-time reverse transcription polymerase chain reaction (RT-qPCR) and four PRRSV antibody ELISA assays (IgM, IgA, IgG, and Commercial Kit). All sow serum samples were negative by PRRSV RT-qPCR, but 9 of 600 oral fluid samples tested positive at two laboratories. Open reading frame 5 (ORF5) sequencing of 2 of the 9 positive oral fluid samples identified wild-type viruses as the source of the infection. A comparison of antibody responses in RT-qPCR positive vs. negative oral fluid samples showed significantly higher IgG S/P ratios in RT-qPCR-positive oral fluid samples (mean S/P 3.46 vs. 2.36; p=0.02). Likewise, sow serum samples from RT-qPCR-positive litter oral fluid samples showed significantly higher serum IgG (mean S/P 1.73 vs. 0.98; p<0.001) and Commercial Kit (mean S/P 1.97 vs. 0.98; p<0.001) S/P ratios. Overall, the study showed that pre-weaning litter oral fluid samples could provide an efficient and sensitive approach to surveil for PRRSV in infected, vaccinated, or presumed-negative pig breeding herds. Copyright © 2014 Elsevier B.V. All rights reserved.
Use of dried blood spots for the determination of serum concentrations of tamoxifen and endoxifen.
Jager, N G L; Rosing, H; Schellens, J H M; Beijnen, J H; Linn, S C
2014-07-01
The anti-estrogenic effect of tamoxifen is suggested to be mainly attributable to its metabolite (Z)-endoxifen, and a minimum therapeutic threshold for (Z)-endoxifen in serum has been proposed. The objective of this research was to establish the relationship between dried blood spot (DBS) and serum concentrations of tamoxifen and (Z)-endoxifen to allow the use of DBS sampling, a simple and patient-friendly alternative to venous sampling, in clinical practice. Paired DBS and serum samples were obtained from 50 patients using tamoxifen and analyzed using HPLC-MS/MS. Serum concentrations were calculated from DBS concentrations using the formula calculated serum concentration = DBS concentration/([1-haematocrit (Hct)] + blood cell-to-serum ratio × Hct). The blood cell-to-serum ratio was determined ex vivo by incubating a batch of whole blood spiked with both analytes. The average Hct for female adults was imputed as a fixed value. Calculated and analyzed serum concentrations were compared using weighted Deming regression. Weighted Deming regression analysis comparing 44 matching pairs of DBS and serum samples showed a proportional bias for both analytes. Serum concentrations were calculated using [Tamoxifen] serum, calculated = [Tamoxifen] DBS /0.779 and [(Z)-Endoxifen] serum, calculated = [(Z)-Endoxifen] DBS /0.663. Calculated serum concentrations were within 20 % of analyzed serum concentrations in 84 and 100 % of patient samples for tamoxifen and (Z)-endoxifen, respectively. In conclusion, DBS concentrations of tamoxifen and (Z)-endoxifen were equal to serum concentrations after correction for Hct and blood cell-to-serum ratio. DBS sampling can be used in clinical practice.
Serum bile acid concentrations in dairy cattle with hepatic lipidosis.
Garry, F B; Fettman, M J; Curtis, C R; Smith, J A
1994-01-01
This study was designed to evaluate serum bile acid measurements as indicatory, of liver function and/or hepatic fat infiltration in dairy cattle. Serum bile acid concentrations were measured in healthy dairy cattle at different stages of lactation after fasting or feeding. Bile acid concentrations were compared with liver fat content and sulfobromophthalein (BSP) half-life (T 1/2). Serum bile acid concentrations were higher in cows in early lactation and with higher daily milk production. Compared with prefasting values, bile acid concentrations were decreased at 8, 14, and 24 hours of fasting. Blood samples from fed cows at 1- to 2-hour intervals had wide and inconsistent variations in bile acid concentration. Because serum bile acids correlated well with BSP T 1/2, it is suggested that both measurements evaluate a similar aspect of liver function. Neither bile acids nor BSP T 1/2 correlated with differences in liver fat content among cows. Because of large variability in serum bile acid concentrations in fed cows and the lack of correlation of measured values with liver fat content, bile acid determinations do not appear useful for showing changes in hepatic function in fed cows with subclinical hepatic lipidosis nor serve as a screening test for this condition.
High serum 25-hydroxyvitamin D levels are associated with pediatric sepsis.
Aydemir, Gokhan; Cekmez, Ferhat; Kalkan, Gokhan; Fidanci, M Kursat; Kaya, Guven; Karaoglu, Abdulbaki; Meral, Cihan; Arzıman, İbrahim; Karademir, Ferhan; Ayar, Ganime; Gunduz, Ramiz Coskun; Suleymanoglu, Selami
2014-12-01
Despite major advances in intensive care, sepsis continues to be a major cause of morbidity and mortality. Vitamin D is involved in various physiologic functions, including cellular responses during infection and inflammation. The aim of this study was to evaluate diagnostic value of 25-hydroxyvitamin D in childhood sepsis because it can be fatal if diagnosis delayed. The study included 40 children with sepsis and 20 children without sepsis (control group). We included only the patients with high probable sepsis, judged by clinical and laboratory findings, including positive blood culture. Blood samples were collected from patients with sepsis before treatment (pre-treatment group) and 48-72 hours later (post-treatment group). Treatment varied from ampicillin-sulbactam to cephalosporin. Blood samples were collected from control group once on admission. Serum 25-hydroxyvitamin D levels were significantly higher in sepsis (pre-treatment group) than control group (74 ± 8 ng/ml vs. 28 ± 12 ng/ml, p = 0.01) and the serum 25-hydroxyvitamin D levels were decreased to 44 ± 5 ng/ml (p = 0.01) after treatment. Moreover, we found significant positive correlation between 25-hydroxyvitamin D and each of well-know sepsis markers, C-reactive protein, tumor necrosis factor-α and interleukin-6. A cut-off point of 20 ng/mL for serum 25-hydroxyvitamin D showed 84% sensitivity and 76% specificity for sepsis diagnosis. This is the first study evaluating the diagnostic role of vitamin D in pediatric sepsis, thereby suggesting that serum 25-hydroxyvitamin D level can be used as a diagnostic marker for sepsis with high sensitivity and specificity.
Meta-analysis of serum lactate dehydrogenase and prognosis for osteosarcoma.
Fu, Yucheng; Lan, Tao; Cai, Hongliu; Lu, Anwei; Yu, Wei
2018-05-01
A large number of studies have reported the relationships between serum lactate dehydrogenase (LDH) and prognosis of osteosarcoma. However, the result is still controversial and no consensus has been reached. Therefore, we performed a meta-analysis to evaluate the prognostic role of serum LDH in osteosarcoma patients. We performed the systematic computerized search for eligible articles from PubMed, Embase, and Cochrane databases until December 21, 2017. The pooled hazard ratio (HR) and 95% confidence intervals (CIs) of overall survival (OS) and event-free survival (EFS) were obtained to assess the prognostic value of serum LDH. A total of 18 studies with 2543 osteosarcoma patients were included. Overall, 15 studies assessed the elevated serum LDH level on OS and the pooled HR was 1.87 (95% CI = 1.58-2.20). Meanwhile, the pooled HR to evaluate the relationship between serum LDH and EFS in 9 studies was 1.78 (95% CI = 1.51-2.10). The same results were acquired when these studies were stratified by Enneking stage, geographic region, and sample size. No heterogeneity existed between these subgroups (P > .05). Begg's funnel plot and Egger's test (OS: P = .04; EFS: P = .34) showed that possible publication bias might exist in OS studies. Sensitivity analysis suggested the pooled HR was robust. This meta-analysis demonstrates that elevated serum LDH level is apparently associated with lower EFS rate and serum LDH could be a prognostic biomarker for osteosarcoma patients.
NASA Astrophysics Data System (ADS)
Li, Shaoxin; Zhang, Yanjiao; Xu, Junfa; Li, Linfang; Zeng, Qiuyao; Lin, Lin; Guo, Zhouyi; Liu, Zhiming; Xiong, Honglian; Liu, Songhao
2014-09-01
This study aims to present a noninvasive prostate cancer screening methods using serum surface-enhanced Raman scattering (SERS) and support vector machine (SVM) techniques through peripheral blood sample. SERS measurements are performed using serum samples from 93 prostate cancer patients and 68 healthy volunteers by silver nanoparticles. Three types of kernel functions including linear, polynomial, and Gaussian radial basis function (RBF) are employed to build SVM diagnostic models for classifying measured SERS spectra. For comparably evaluating the performance of SVM classification models, the standard multivariate statistic analysis method of principal component analysis (PCA) is also applied to classify the same datasets. The study results show that for the RBF kernel SVM diagnostic model, the diagnostic accuracy of 98.1% is acquired, which is superior to the results of 91.3% obtained from PCA methods. The receiver operating characteristic curve of diagnostic models further confirm above research results. This study demonstrates that label-free serum SERS analysis technique combined with SVM diagnostic algorithm has great potential for noninvasive prostate cancer screening.
Evaluation of Aspergillus PCR protocols for testing serum specimens.
White, P Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J G; McCulloch, Elaine; Barnes, Rosemary A; Donnelly, J Peter; Loeffler, Juergen
2011-11-01
A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance.
Evaluation of Aspergillus PCR Protocols for Testing Serum Specimens▿†
White, P. Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J. G.; McCulloch, Elaine; Barnes, Rosemary A.; Donnelly, J. Peter; Loeffler, Juergen
2011-01-01
A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance. PMID:21940479
Guthmann, Jean-Paul; Klovstad, Hilde; Boccia, Delia; Hamid, Nuha; Pinoges, Loretxu; Nizou, Jacques-Yves; Tatay, Mercedes; Diaz, Francisco; Moren, Alain; Grais, Rebecca Freeman; Ciglenecki, Iza; Nicand, Elisabeth; Guerin, Philippe Jean
2006-06-15
The conflict in Darfur, Sudan, was responsible for the displacement of 1.8 million civilians. We investigated a large outbreak of hepatitis E virus (HEV) infection in Mornay camp (78,800 inhabitants) in western Darfur. To describe the outbreak, we used clinical and demographic information from cases recorded at the camp between 26 July and 31 December 2004. We conducted a case-cohort study and a retrospective cohort study to identify risk factors for clinical and asymptomatic hepatitis E, respectively. We collected stool and serum samples from animals and performed a bacteriological analysis of water samples. Human samples were tested for immunoglobulin G and immunoglobulin M antibody to HEV (for serum samples) and for amplification of the HEV genome (for serum and stool samples). In 6 months, 2621 hepatitis E cases were recorded (attack rate, 3.3%), with a case-fatality rate of 1.7% (45 deaths, 19 of which involved were pregnant women). Risk factors for clinical HEV infection included age of 15-45 years (odds ratio, 2.13; 95% confidence interval, 1.02-4.46) and drinking chlorinated surface water (odds ratio, 2.49; 95% confidence interval, 1.22-5.08). Both factors were also suggestive of increased risk for asymptomatic HEV infection, although this was not found to be statistically significant. HEV RNA was positively identified in serum samples obtained from 2 donkeys. No bacteria were identified from any sample of chlorinated water tested. Current recommendations to ensure a safe water supply may have been insufficient to inactivate HEV and control this epidemic. This research highlights the need to evaluate current water treatment methods and to identify alternative solutions adapted to complex emergencies.
Schueler, R O; White, G; Schueler, R L; Steiner, J M; Wassef, A
2018-05-01
To determine the differences in serum canine pancreatic lipase immunoreactivity between dogs with intervertebral disc herniation and healthy control dogs. Eighty-four client-owned dogs with intervertebral disc herniation, diagnosed by neurologic examination and imaging, and 18 healthy control dogs. Samples of whole blood were collected within 90 minutes of admission. Serum canine pancreatic lipase immunoreactivity concentrations were measured by a commercial immunoassay and evaluated for association with intervertebral disc herniation, signalment, neurolocalisation and the preadmission administration of glucocorticosteriods or non-steroidal anti-inflammatory drugs. Serum canine pancreatic lipase immunoreactivity concentrations were statistically increased in dogs with intervertebral disc herniation (P<0·01, n=38). A subgroup of dogs (19/38) with elevated canine pancreatic lipase immunoreactivity concentrations was re-evaluated between 2 and 4 weeks later, and 15 had resolution of clinical signs and values less than 200 μg/L. Serum canine pancreatic lipase immunoreactivity concentrations were not significantly correlated with clinical gastrointestinal disease, neurolocalisation or the preadmission administration of corticosteroids or non-steroidal anti-inflammatory drugs. These results suggest that serum canine pancreatic lipase immunoreactivity concentrations are significantly elevated in dogs with intervertebral disc herniation. © 2018 British Small Animal Veterinary Association.
Differences in metabolite profiles caused by pre-analytical blood processing procedures.
Nishiumi, Shin; Suzuki, Makoto; Kobayashi, Takashi; Yoshida, Masaru
2018-05-01
Recently, the use of metabolomic analysis of human serum and plasma for biomarker discovery and disease diagnosis in clinical studies has been increasing. The feasibility of using a metabolite biomarker for disease diagnosis is strongly dependent on the metabolite's stability during pre-analytical blood processing procedures, such as serum or plasma sampling and sample storage prior to centrifugation. However, the influence of blood processing procedures on the stability of metabolites has not been fully characterized. In the present study, we compared the levels of metabolites in matched human serum and plasma samples using gas chromatography coupled with mass spectrometry and liquid chromatography coupled with mass spectrometry. In addition, we evaluated the changes in plasma metabolite levels induced by storage at room temperature or at a cold temperature prior to centrifugation. As a result, it was found that 76 metabolites exhibited significant differences between their serum and plasma levels. Furthermore, the pre-centrifugation storage conditions significantly affected the plasma levels of 45 metabolites. These results highlight the importance of blood processing procedures during metabolome analysis, which should be considered during biomarker discovery and the subsequent use of biomarkers for disease diagnosis. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Córdoba, J; Olaso, V; Molina, J M; López Viedma, B; Argüello, L; Ortiz, V; Esteban, R J; Garijo, R; Pastor, M; Gobernado, M
2000-01-01
Two standardized techniques, Quantiplex (bDNA-2.0) and Amplicor Monitor have been evaluated for the quantification of virus load of HCV with these objectives: a) determinate the relationship between virus load and genotype, and b) evaluate the virus load in serial serum samples and in patients with normal or slightly increased liver enzymes in an area with a high prevalence of genotype 1. A significant correlation of 0.7 (p < 0.0001) in virus load has been observed by both methods, but the virus load is smaller by Monitor than by Quantiplex and does not depend on genotype. The relationship Monitor/Quantiplex is smaller in patients with non-1 genotype than in patients with genotype 1a (p = 0.01) and 1b (p = 0.005). Virus characteristics are similar in patients with normal or slightly increased enzymes than in patients with high enzymes. Virus load by both methods is not related to the age, sex, know duration of the infection, transmission manner of the infection neither to the histologic activity index. The virus load not depends on genotype. The determination of virus load in a single serum sample adequately reflects the virus load are in several serum samples in patients with chronic HCV infection. The genotype and the virus load are similar in patients with normal enzymes than in patients with high enzymes.
Guswanto, Azirwan; Allamanda, Puttik; Mariamah, Euis Siti; Munkjargal, Tserendorf; Tuvshintulga, Bumduuren; Takemae, Hitoshi; Sivakumar, Thillaiampalam; AbouLaila, Mahmoud; Terkawi, Mohamad Alaa; Ichikawa-Seki, Madoka; Nishikawa, Yoshifumi; Yokoyama, Naoaki; Igarashi, Ikuo
2017-05-30
Three types of immunochromatographic test (ICT) strips were prepared for the detection of an antibody response against spherical body protein 4 (SBP-4) of Babesia bovis (bovICT), C-terminal-truncated rhoptry-associated protein 1 (rRAP1/CT17) of B. bigemina (bigICT), and the combination of both proteins (dual-ICT). The evaluation of their performance was conducted using a confirmed positive and negative serum panel for B. bovis and B. bigemina. Together with ELISA, the ICT strips were applied to determine the seroprevalence of bovine babesiosis in Western Java, Indonesia. Among 991 serum samples, 28.4%, 25.3%, and 24.5% of cattle were detected to be seropositive to B. bovis infection using ELISA, bovICT, and dual-ICT, respectively. B. bigemina seropositive was detected in 27.1%, 24.2%, and 22.8% of samples using ELISA, bigICT, and dual-ICT, respectively. The comparison of ICT strips and ELISA results using field serum samples showed good agreement with Kappa values >0.7 between all methods The application of ICT strips is preferable in the field situations where rapid diagnosis is required. Furthermore, the data showed the current seroprevalence of bovine babesiosis in Western Java, Indonesia, and efficient control strategies are needed to reduce economic losses due to the disease. Copyright © 2017 Elsevier B.V. All rights reserved.
The Antimicrobial Peptide Lysozyme Is Induced after Multiple Trauma
Klüter, Tim; Fitschen-Oestern, Stefanie; Lippross, Sebastian; Weuster, Matthias; Pufe, Thomas; Tohidnezhad, Mersedeh; Beyer, Andreas; Seekamp, Andreas; Varoga, Deike
2014-01-01
The antimicrobial peptide lysozyme is an important factor of innate immunity and exerts high potential of antibacterial activity. In the present study we evaluated the lysozyme expression in serum of multiple injured patients and subsequently analyzed their possible sources and signaling pathways. Expression of lysozyme was examined in blood samples of multiple trauma patients from the day of trauma until 14 days after trauma by ELISA. To investigate major sources of lysozyme, its expression and regulation in serum samples, different blood cells, and tissue samples were analysed by ELISA and real-time PCR. Neutrophils and hepatocytes were stimulated with cytokines and supernatant of Staphylococcus aureus. The present study demonstrates the induction and release of lysozyme in serum of multiple injured patients. The highest lysozyme expression of all tested cells and tissues was detected in neutrophils. Stimulation with trauma-related factors such as interleukin-6 and S. aureus induced lysozyme expression. Liver tissue samples of patients without trauma show little lysozyme expression compared to neutrophils. After stimulation with bacterial fragments, lysozyme expression of hepatocytes is upregulated significantly. Toll-like receptor 2, a classic receptor of Gram-positive bacterial protein, was detected as a possible target for lysozyme induction. PMID:25258475
Parkhouse, R Michael E; Carpio, Arturo; Campoverde, Alfredo; Sastre, Patricia; Rojas, Glenda; Cortez, María Milagros
2018-02-01
To evaluate diagnosis of active neurocysticercosis, paired cerebral spinal fluid (CSF) and serum samples from 24 neurocysticercosis (NCC) patients and 17 control neurological patients were assayed in the HP10 Taenia antigen (Ag) ELISA. The CSF samples were also tested with an HP10 Lateral Flow Assay (LFA). The HP10 Ag was detected by ELISA in the CSF of 5/5 patients with Definitive extraparenchymal NCC, and in 4/5 of the corresponding sera. In the Definitive parenchymal group, on the other hand, the HP10 Ag was absent in 2/3 CSF (with a very low value in the one positive sample) and all the corresponding serum samples. Samples of CSF from 4/7 patients in the Probable parenchymal group, were also significantly HP10 Ag positive, suggesting the presence of extraparenchymal cysts not identified by the imaging studies. With the possible exception of one patient, the corresponding serum samples of the Probable parenchymal NCC group, were all HP10 Ag negative. Samples of CSF from 9 NCC patients diagnosed with Mixed parenchymal and extraparenchymal NCC were all significantly HP10 Ag positive, confirming the presence of extraparenchymal cysts, with only 7/9 of the corresponding serum samples being HP10 positive. Thus detection of the HP10 Ag indicates extraparenchymal and not parenchymal cyst localization and is more sensitive with CSF than serum. Three neurological patients clinically diagnosed as subarachnoid cyst, hydrocephalus and tuberculoma, respectively, were clearly positive for HP10 Ag. Of these, two were confirmed as NCC by subsequent imaging; the third died prior to further examination. Thus, a total of 8 patients had their clinical diagnosis questioned. Finally, there was good agreement between the HP10 Ag ELISA and LFA with CSF samples giving an optical density ≥0.4 in the ELISA assay. In conclusion, the HP10 Ag assay should provide a valuable and reciprocal tool in the clinical diagnosis and follow up of extraparenchymal NCC. Copyright © 2017 Elsevier B.V. All rights reserved.
Simioni, Andreza Ribeiro; Rodrigues, Marcilene M A; Primo, Fernando L; Morais, Paulo C; Tedesco, Antonio Claudio
2011-04-01
This study reports on the development and characterization of bovine serum albumin (BSA) nanospheres containing Silicon(IV) phthalocyanine (NzPc) and/or maghemite nanoparticles (MNP), the latter introduced via ionic magnetic fluid (MF). The nanosized BSA-loaded samples were designed for synergic application while combining Photodynamic Therapy and Hyperthermia. Incorporation of MNP in the albumin-based template, allowing full control of the magnetic content, was accomplished by adding a highly-stable ionic magnetic fluid sample to the albumin suspension, following heat denaturing. The material's evaluation was performed using Zeta potential measurements and scanning electron microscopy. The samples were characterized by steady-state techniques and time-resolved fluorescence. The in vitro assay, using human fibroblasts, revealed no cytotoxic effect in all samples investigated, demonstrating the potential of the tested system as a synergistic drug delivery system.
Koblavi-Dème, Stéphania; Maurice, Chantal; Yavo, Daniel; Sibailly, Toussaint S.; N′guessan, Kabran; Kamelan-Tano, Yvonne; Wiktor, Stefan Z.; Roels, Thierry H.; Chorba, Terence; Nkengasong, John N.
2001-01-01
To evaluate serologic testing algorithms for human immunodeficiency virus (HIV) based on a combination of rapid assays among persons with HIV-1 (non-B subtypes) infection, HIV-2 infection, and HIV-1–HIV-2 dual infections in Abidjan, Ivory Coast, a total of 1,216 sera with known HIV serologic status were used to evaluate the sensitivity and specificity of four rapid assays: Determine HIV-1/2, Capillus HIV-1/HIV-2, HIV-SPOT, and Genie II HIV-1/HIV-2. Two serum panels obtained from patients recently infected with HIV-1 subtypes B and non-B were also included. Based on sensitivity and specificity, three of the four rapid assays were evaluated prospectively in parallel (serum samples tested by two simultaneous rapid assays) and serial (serum samples tested by two consecutive rapid assays) testing algorithms. All assays were 100% sensitive, and specificities ranged from 99.4 to 100%. In the prospective evaluation, both the parallel and serial algorithms were 100% sensitive and specific. Our results suggest that rapid assays have high sensitivity and specificity and, when used in parallel or serial testing algorithms, yield results similar to those of enzyme-linked immunosorbent assay-based testing strategies. HIV serodiagnosis based on rapid assays may be a valuable alternative in implementing HIV prevention and surveillance programs in areas where sophisticated laboratories are difficult to establish. PMID:11325995
A fully-integrated aptamer-based affinity assay platform for monitoring astronaut health in space.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xianbin; Durland, Ross H.; Hecht, Ariel H.
2010-07-01
Here we demonstrate the suitability of robust nucleic acid affinity reagents in an integrated point-of-care diagnostic platform for monitoring proteomic biomarkers indicative of astronaut health in spaceflight applications. A model thioaptamer targeting nuclear factor-kappa B (NF-{kappa}B) is evaluated in an on-chip electrophoretic gel-shift assay for human serum. Key steps of (i) mixing sample with the aptamer, (ii) buffer exchange, and (iii) preconcentration of sample were successfully integrated upstream of fluorescence-based detection. Challenges due to (i) nonspecific interactions with serum, and (ii) preconcentration at a nanoporous membrane are discussed and successfully resolved to yield a robust, rapid, and fully-integrated diagnostic system.
Cardoso, Luciene C; Martins, Denise C L; Campos, Denise V B; Santos, Luciana M; Corrêa da Costa, Vânia M; Rosenthal, Doris; Vaisman, Mario; Violante, Alice H D; Carvalho, Denise P
2002-09-01
The aim of the present study was to compare the effects of iopanoic acid (IOP) or a saturated solution of potassium iodide (SSKI) administration to patients with toxic diffuse goiters (TDG). Patients with TDG are treated with thionamides and high doses of iodine preoperatively. In this study, two types of preoperative drug regimens were used: propylthiouracil or methimazole plus SSKI for 10-15 days (n=8) or IOP for 7 days (n=6). Serum thyroid hormones (total and free thyroxine (T(4)), total tri-iodothyronine (T(3)) and reverse T(3) (rT(3)), were evaluated after 7 days of either SSKI or IOP treatment, and after 10-15 days of SSKI administration. During thyroidectomy, samples of thyroid gland were obtained to evaluate thyroperoxidase and thyroid H(2)O(2)-generating activities. Serum total T(3) was significantly decreased after 7 days of either treatment, and serum rT(3) was significantly increased in IOP-treated patients. Serum total and free T(4) were unaffected by 7 days of IOP treatment, but decreased after 7 days of SSKI treatment, although significantly diminished levels were only reached after a further 3-8 days of SSKI administration. During both drug regimens, serum TSH remained low (SSKI: 0.159+/-0.122; IOP: 0.400+/-0.109 microU/ml). Thyroperoxidase activity was significantly lower in thyroid samples from patients treated with SSKI for 10-15 days than in the thyroid glands from IOP-treated patients. However, thyroid H(2)O(2) generation was inhibited in samples from patients treated with either IOP or SSKI. We show herein that IOP treatment can be effective in the management of hyperthyroidism and that this drug inhibits thyroid NADPH oxidase activity, just as previously described for SSKI, probably due to its iodine content.
Prevalence of pernicious anemia in patients with macrocytic anemia and low serum B12
AA, Abdulmanea; AH, Alsaeed; AP, Shaik; FH, AlGahtani
2014-01-01
Objective: The current research evaluated the prevalence of pernicious anemia (PA) in patients with macrocytic anemia (high MCV) and low serum B12 in Riyadh. Methods: Blood testing was done in 77 patients (males: 45.5%, females: 54.5%) with macrocytic anemia; 84 patients; (males: 23.8%, females: 76.2%) with low serum B12 and 30 healthy subjects. Complete blood count, differential count, folic acid, vitamin B12, intrinsic factor, gastric parietal cell antibodies and holotranscobalamin II were assessed. Results: A total of five subjects from 161 patients had PA; three of these patients had macrocyticanemia (3.90%) and two patients had low serum B12 (2.38%). Significant differences (p<0.05) in some hematological, immunological, biochemical parameters were found in subjects with macrocytic anemia and low serum B12 compared to controls. Conclusions: Pernicious anemia in patients with macrocytic anemia and low serum B12 was for the selected sample size can be assumed to be uncommon in Riyadh, Saudi Arabia. PMID:25674111
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-01-01
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70–200 mg/dL), revealing high system performance for a wide glycemic state range (45–500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting. PMID:27669267
Ince, Bahar; Coban, Halil; Turker, Gokhan; Ertekin, Emine; Ince, Orhan
2013-05-01
The aim of this study was to investigate the effect of a common veterinary antibiotic in biogas plants. 20 mg/kg of oxytetracycline was intramuscularly injected into a cow and its concentration in manure, which was sampled daily during the following 20 days, was measured. A total of 20 % of the injected oxytetracycline was detected in manure. Collected manure samples on days 1, 2, 3, 5, 10, 15, and 20 were digested in triplicate serum bottles at 37 °C for 30 days. Control serum bottles produced 255 ± 13 mL biogas, whereas 50-60 % inhibitions were obtained for the serum bottles operated with samples collected for the 5 days after medication. Multivariate statistics used for the evaluation of FISH results showed that Methanomicrobiales were the main methanogenic group responsible for most of the biogas production. Numbers of active Bacteria and Methanomicrobiales were negatively correlated with the presence of oxytetracycline, whereas Methanosarcinales and Methanobacteriales were less affected.
Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I
2015-03-01
The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.
Fathipour, Vahid; Khaki, Zohreh; Nassiri, Seyyed Mehdi
2018-01-01
Recently, matrix metalloproteinases (MMP), in particular the gelatinases MMP-2 and MMP-9, generally considered as tumor markers for clinical applications. A longitudinal 2-years follow-up survey was performed on dogs with cutaneous tumor. Serum samples were obtained from 22 dogs with different cutaneous tumors and 22 health dogs at the time of surgery and one month, three months and one year after surgery. Gelatin zymography, hematological and biochemical assessment were performed for all serum samples. The serum alkaline phosphatase activity in dogs with malignant tumors was significantly higher than that in dogs with benign tumors and control cases. Latent forms of MMP-2 and MMP-9 were detected in all of the tumor cases. Gelatin zymography showed active form of MMP-9 in 12 cases (three benign and nine malignant tumors) and active form of MMP-2 in one fibrosarcoma case. Serum activity of active-MMP-9 and total MMP-9 was significantly higher in dogs with cutaneous tumors than those in controls. Tumor cases had higher serum activity of active-MMP-9 rather than controls. MMPs and alkaline phosphatase activities in serum were decreased significantly after surgery. Only one case with perianal gland adenoma showed recurrence of tumor four months after surgery in which active form of MMP-9 had identified one month before recurrence. According to the findings, it will be useful to measure ALP, MMP-2 and MMP-9 activities in the serum of dogs with cutaneous tumor for determination of tumor behavior before surgical treatment.
Ramos, Inês I; Magalhães, Luís M; Barreiros, Luisa; Reis, Salette; Lima, José L F C; Segundo, Marcela A
2018-01-01
Immunoglobulin G (IgG) represents the major fraction of antibodies in healthy adult human serum, and deviations from physiological levels are a generic marker of disease corresponding to different pathologies. Therefore, screening methods for IgG evaluation are a valuable aid to diagnostics. The present work proposes a rapid, automatic, and miniaturized method based on UV-vis micro-bead injection spectroscopy (μ-BIS) for the real-time determination of human serum IgG with label-free detection. Relying on attachment of IgG in rec-protein G immobilized in Sepharose 4B, a bioaffinity column is automatically assembled, where IgG is selectively retained and determined by on-column optical density measurement. A "dilution-and-shoot" approach (50 to 200 times) was implemented without further sample treatment because interferences were flushed out of the column upon sample loading, with minimization of carryover and cross-contamination by automatically discarding the sorbent (0.2 mg) after each determination. No interference from human serum albumin at 60 mg mL -1 in undiluted sample was found. The method allowed IgG determination in the range 100-300 μg mL -1 (corresponding to 5.0-60 mg mL -1 in undiluted samples), with a detection limit of 33 μg mL -1 (1.7 mg mL -1 for samples, dilution factor of 50). RSD values were < 9.4 and < 11.7%, for intra and inter-assay precision, respectively, while recovery values for human serum spiked with IgG at high pathological levels were 97.8-101.4%. Comparison to commercial ELISA kit showed no significant difference for tested samples (n = 8). Moreover, time-to-result decreased from several hours to < 5 min and analysis cost decreased 10 times, showing the potential of the proposed approach as a point-of-care method. Graphical abstract Micro-Bead Injection Spectroscopy method for real time, automated and label-free determination of total serum human Immunoglobulin G (IgG). The method was designed for Lab-on-Valve (LOV) platforms using a miniaturised protein G bioaffinity separative approach. IgG are separated from serum matrix components upon quantification with low non-specific binding in less than 5 min.
Determining skeletal maturation using insulin-like growth factor I (IGF-I) test.
Gupta, Shreya; Jain, Sandhya; Gupta, Puneet; Deoskar, Anuradha
2012-11-01
To investigate the validity of Insulin like Growth Factor -1(IGF-1) as a skeletal maturity indicator by comparing serum IGF-1 levels with the stages in cervical vertebral maturation (CVM) and in the middle phalanx of the third finger (MP3). The study population was selected by using simple random sampling technique and consisted of 30 female subjects in the age range of 8-23 years who had blood sample, cephalometric and MP3 radiographs taken on the same day. Serum IGF-I estimation was carried out on the blood samples using chemiluminescence immunoassay (CLIA) method. CVM was evaluated using method by Baccetti et al and MP3 staging was done using Rajagopal & Kansal method. Mean IGF-1 level between the stages was compared by Kruskal-Wallis and Mann Whitney test. Serum IGF-1 levels in females correlate well with skeletal maturity determined by CVM and MP3 stages and increase sharply during early pubertal stages followed by a decrease in late puberty. In addition we hypothesis that serum IGF-1 testing can be undertaken as a preliminary screening test in patients in whom the orthodontist predicts the possibility of using myofunctional appliance but in whom the chronologic age is not suggestive for a growth modification therapy. The finding of the study highlights the fact that the serum IGF-1 estimation can be a valuable tool in assessing skeletal maturation. Copyright © 2012 Società Italiana di Ortodonzia SIDO. Published by Elsevier Srl. All rights reserved.
Tvedt, Tor Henrik Anderson; Rye, Kristin Paulsen; Reikvam, Håkon; Brenner, Annette K; Bruserud, Øystein
2015-03-01
Cytokines, soluble adhesion molecules and metalloproteinases can be detected in human serum or plasma samples. Such systemic levels are widely used as biomarkers in epidemiological and clinical studies. We prepared serum samples and three types of plasma samples (EDTA, heparin, citric acid) from 20 healthy individuals. The levels of 31 cytokines, four soluble adhesion molecules and eight matrix metalloproteinases were analyzed by Luminex technology. Most mediators showed detectable levels in both plasma and serum. Several mediators that can be released by platelets showed increased serum levels, especially CCL5 and CD40L, but for the other mediators the serum levels did not correlate with peripheral blood platelet counts and for these last mediators serum and plasma levels often showed strong correlations. The use of bivalirudin for anticoagulation significantly increased and citric acid combined with platelet inhibitors (ticagrelor, acetylsalicylic acid plus prostaglandin E2) did not alter plasma levels of platelet-store mediators compared with citric acid alone. The impact of sample preparation differed between mediators; for many mediators strong correlations were seen between serum and plasma levels even when absolute levels differed. Soluble adhesion molecule levels showed only minor differences between samples. Unsupervised hierarchical clustering suggested that the effect of sampling/preparation was strongest for serum and heparin plasma samples. Careful standardization of sample preparation is usually necessary when analyzing systemic mediator levels, and differences caused by sample preparation should be considered as a possible explanation if studies show conflicting results. Copyright © 2015 Elsevier B.V. All rights reserved.
Serum Adipocytokine Levels as Surrogate Markers for Disease Activity of Crohn's Disease.
Kim, Su Hwan; Jang, Seung Hyeon; Kim, Ji Won; Kim, Byeong Gwan; Lee, Kook Lae; Kim, You Sun; Han, Dong Soo; Kim, Joo Sung
2017-05-01
Determining inflammatory activity is crucial for assessing disease activity and for tailoring therapy in patients with Crohn׳s disease (CD). This study aimed to evaluate adipocytokine levels in patients with CD and to determine whether they can serve as surrogate markers for disease activity. Serum samples and information regarding the clinical features of patients in the CD Network Project registry were collected from March 2009 to February 2012. Patients with CD and disease duration of at least 2 years were enrolled in this study. Fasting serum leptin, adiponectin, obestatin and ghrelin levels were measured, and their correlation with clinical features of the patients was analyzed. Serum adipocytokine levels were evaluated according to disease activity as determined by CD activity index score. A total of 153 patients with CD were included. Serum ghrelin levels negatively correlated with patient age (P = 0.041) and age at diagnosis (P = 0.017), and positively correlated with C-reactive protein (CRP) levels (P = 0.017). Multiple regression analysis showed that serum ghrelin levels were related only to CRP levels (P = 0.032). Like ghrelin, serum leptin levels were also related to CRP levels (P < 0.001). Obestatin and adiponectin levels were not related to CRP levels. Serum adipocytokine levels did not significantly differ across different disease locations or behaviors. Serum ghrelin levels were significantly lower in patients with CD with a history of surgery than in those without (P = 0.007). Serum ghrelin and leptin levels may be useful as surrogate markers for disease activity in patients with CD. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
Depauw, Sarah; Delanghe, Joris; Whitehouse-Tedd, Katherine; Kjelgaard-Hansen, Mads; Christensen, Michelle; Hesta, Myriam; Tugirimana, Pierrot; Budd, Jane; Dermauw, Veronique; Janssens, Geert P J
2014-09-01
Renal and gastrointestinal pathologies are widespread in the captive cheetah (Acinonyx jubatus) population but are often diagnosed at a late stage, because diagnostic tools are limited to the evaluation of clinical signs or general blood examination. Presently, no data are available on serum proteins and acute-phase proteins in cheetahs during health or disease, although they might be important to improve health monitoring. This study aimed to quantify serum proteins by capillary electrophoresis in 80 serum samples from captive cheetahs, categorized according to health status and disease type. Moreover, serum amyloid A concentrations were measured via a turbidimetric immunoassay validated in domestic cats, whereas haptoglobin and C-reactive protein were determined by non-species-specific functional tests. Cheetahs classified as healthy had serum protein and acute phase protein concentrations within reference ranges for healthy domestic cats. In contrast, unhealthy cheetahs had higher (P < 0.001) serum amyloid A, alpha2-globulin, and haptoglobin concentrations compared with the healthy subgroup. Moreover, serum amyloid A (P = 0.020), alpha2-globulin (P < 0.001) and haptoglobin (P = 0.001) concentrations in cheetahs suffering from chronic kidney disease were significantly greater compared to the reportedly healthy cheetahs. Our study indicates that serum proteins in the cheetah can be analyzed by routine capillary electrophoresis, whereas acute-phase proteins can be measured using available immunoassays or non-species-specific techniques, which are also likely to be applicable in other exotic felids. Moreover, results suggest that serum amyloid A and haptoglobin are important acute-phase proteins in the diseased cheetah and highlight the need to evaluate their role as early-onset markers for disease.
Elsohaby, Ibrahim; McClure, J Trenton; Riley, Christopher B; Bryanton, Janet; Bigsby, Kathryn; Shaw, R Anthony
2018-02-20
Attenuated total reflectance infrared (ATR-IR) spectroscopy is a simple, rapid and cost-effective method for the analysis of serum. However, the complex nature of serum remains a limiting factor to the reliability of this method. We investigated the benefits of coupling the centrifugal ultrafiltration with ATR-IR spectroscopy for quantification of human serum IgA concentration. Human serum samples (n = 196) were analyzed for IgA using an immunoturbidimetric assay. ATR-IR spectra were acquired for whole serum samples and for the retentate (residue) reconstituted with saline following 300 kDa centrifugal ultrafiltration. IR-based analytical methods were developed for each of the two spectroscopic datasets, and the accuracy of each of the two methods compared. Analytical methods were based upon partial least squares regression (PLSR) calibration models - one with 5-PLS factors (for whole serum) and the second with 9-PLS factors (for the reconstituted retentate). Comparison of the two sets of IR-based analytical results to reference IgA values revealed improvements in the Pearson correlation coefficient (from 0.66 to 0.76), and the root mean squared error of prediction in IR-based IgA concentrations (from 102 to 79 mg/dL) for the ultrafiltration retentate-based method as compared to the method built upon whole serum spectra. Depleting human serum low molecular weight proteins using a 300 kDa centrifugal filter thus enhances the accuracy IgA quantification by ATR-IR spectroscopy. Further evaluation and optimization of this general approach may ultimately lead to routine analysis of a range of high molecular-weight analytical targets that are otherwise unsuitable for IR-based analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Mendicino, Diego; Stafuza, Mariana; Colussi, Carlina; del Barco, Mónica; Streiger, Mirtha; Moretti, Edgardo
2014-01-01
Many patients with Chagas disease live in remote communities that lack both equipment and trained personnel to perform a diagnosis by conventional serology (CS). Thus, reliable tests suitable for use under difficult conditions are required. In this study, we evaluated the ability of personnel with and without laboratory skills to perform immunochromatographic (IC) tests to detect Chagas disease at a primary health care centre (PHCC). We examined whole blood samples from 241 patients and serum samples from 238 patients. Then, we calculated the percentage of overall agreement (POA) between the two groups of operators for the sensitivity (S), specificity (Sp) and positive (PPV) and negative (NPV) predictive values of IC tests compared to CS tests. We also evaluated the level of agreement between ELISAs and indirect haemagglutination (IHA) tests. The readings of the IC test results showed 100% agreement (POA = 1). The IC test on whole blood showed the following values: S = 87.3%; Sp = 98.8%; PPV = 96.9% and NPV = 95.9%. Additionally, the IC test on serum displayed the following results: S = 95.7%; Sp = 100%; PPV = 100% and NPV = 98.2%. Using whole blood, the agreement with ELISA was 96.3% and the agreement with IHA was 94.1%. Using serum, the agreement with ELISA was 97.8% and the agreement with IHA was 96.6%. The IC test performance with serum samples was excellent and demonstrated its usefulness in a PHCC with minimal equipment. If the IC test S value and NPV with whole blood are improved, then this test could also be used in areas lacking laboratories or specialised personnel. PMID:25466624
Zimmermann, Elke; Hittmair, Katharina M; Suchodolski, Jan S; Steiner, Jörg M; Tichy, Alexander; Dupré, Gilles
2013-05-01
To evaluate serum feline-specific pancreatic lipase immunoreactivity (fPLI) concentrations and abdominal ultrasonographic findings in cats with trauma resulting from high-rise syndrome. Prospective case series. Animals-34 client-owned cats. From cats evaluated because of high-rise syndrome between March and October 2009, a blood sample was obtained for measurement of serum fPLI concentration within 12 hours after the fall and at 24, 48, and 72 hours after the first blood collection. Pancreatitis was diagnosed in cats with an fPLI concentration > 5.4 μg/L. Each cat had abdominal ultrasonography performed twice 48 hours apart, and pancreatic trauma was assessed via detection of pancreatic enlargement, hypoechoic or heteroechoic pancreatic parenchyma, hyperechoic mesentery, and peritoneal effusion. Cats were assigned 1 point for each abnormality present, and a cumulative score ≥ 3 was considered suggestive of traumatic pancreatitis. Traumatic pancreatitis was diagnosed in 9 and 8 cats on the basis of serum fPLI concentration and ultrasonographic findings, respectively. For cats with pancreatitis, fPLI concentration was significantly higher at 12 and 24 hours after the fall than at 48 and 72 hours after the fall, and serum fPLI concentration decreased as time after the fall increased. Significant agreement existed between the use of serum fPLI concentration and abdominal ultrasonography for the diagnosis of traumatic pancreatitis. Cats with high-rise syndrome often had serum fPLI concentrations > 5.4 μg/L within 12 hours after the fall, and concurrent evaluation of those cats via abdominal ultrasonography twice, 48 hours apart, improved detection of traumatic pancreatitis.
de Freitas Raso, Tânia; Seixas, Gláucia Helena Fernandes; Guedes, Neiva Maria Robaldo; Pinto, Aramis Augusto
2006-10-31
Chlamydophila psittaci (C. psittaci) infection was evaluated in 77 free-living nestlings of Blue-fronted Amazon parrots (Amazona aestiva) and Hyacinth macaws (Anodorhynchus hyacinthinus) in the Pantanal of Mato Grosso do Sul, Brazil. Tracheal and cloacal swab samples from 32 wild parrot and 45 macaw nestlings were submitted to semi-nested PCR, while serum samples were submitted to complement fixation test (CFT). Although all 32 Amazon parrot serum samples were negative by CFT, cloacal swabs from two birds were positive for Chlamydophila DNA by semi-nested PCR (6.3%); these positive birds were 32 and 45 days old. In macaws, tracheal and cloacal swabs were positive in 8.9% and 26.7% of the samples, respectively. Complement-fixing antibodies were detected in 4.8% of the macaw nestlings; macaw nestlings with positive findings were between 33 and 88 days old. These results indicate widespread dissemination of this pathogen in the two evaluated psittacine populations. No birds had clinical signs suggestive of chlamydiosis. To the best of our knowledge, this is the first report on C. psittaci in free-living Blue-fronted Amazon parrots and Hyacinth macaws in Brazil.
[Characterization of epithelial primary culture from human conjunctiva].
Rivas, L; Blázquez, A; Muñoz-Negrete, F J; López, S; Rebolleda, G; Domínguez, F; Pérez-Esteban, A
2014-01-01
To evaluate primary cultures from human conjunctiva supplemented with fetal bovine serum, autologous serum, and platelet-rich autologous serum, over human amniotic membrane and lens anterior capsules. One-hundred and forty-eight human conjunctiva explants were cultured in CnT50(®) supplemented with 1, 2.5, 5 and 10% fetal bovine serum, autologous serum and platelet-rich autologous serum. Conjunctival samples were incubated at 37°C, 5% CO2 and 95% HR, for 3 weeks. The typical phenotype corresponding to conjunctival epithelial cells was present in all primary cultures. Conjunctival cultures had MUC5AC-positive secretory cells, K19-positive conjunctival cells, and MUC4-positive non-secretory conjunctival cells, but were not corneal phenotype (cytokeratin K3-negative) and fibroblasts (CD90-negative). Conjunctiva epithelial progenitor cells were preserved in all cultures; thus, a cell culture in CnT50(®) supplemented with 1 to 5% autologous serum over human amniotic membrane can provide better information of epithelial cell differentiation for the conjunctival surface reconstruction. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Tanaka, Yu-Ki; Yajima, Nobuyuki; Higuchi, Yusuke; Yamato, Hideyuki; Hirata, Takafumi
2017-12-01
Herein, we measure the Ca isotope ratios ( 44 Ca/ 42 Ca and 43 Ca/ 42 Ca) in serum and bone samples collected from rats with chronic kidney disease (CKD) or diabetes mellitus (DM). For the serum samples, the isotope ratios are lower for the CKD (δ 44 Ca/ 42 Ca serum = 0.16 ± 0.11‰; 2SD, n = 6) and the DM (δ 44 Ca/ 42 Ca serum = -0.11 ± 0.25‰; 2SD, n = 7) rats than that for the control rats (δ 44 Ca/ 42 Ca serum = 0.25 ± 0.04‰; 2SD, n = 7). Bone samples from two distinct positions of 20 rats in total, namely, the center and proximal parts of the tibial diaphysis, are subject to Ca isotope analysis. The resulting δ 44 Ca/ 42 Ca values for the bone of the proximal part are about 0.3‰ lower than that for the serum samples from the same rats. The larger isotope fractionations between the serum and bone are consistent with previously reported data for vertebrate animals (e.g., Skulan and DePaolo, 1999), which suggests the preferential incorporation of lighter Ca isotopes through bone formation. For the bones from the control and CKD rats, there were no differences in the δ 44 Ca/ 42 Ca values between the positions of the bone. In contrast, the δ 44 Ca/ 42 Ca values of the bone for the DM rats were different between the positions of the bone. Due to the lower bone turnover rate for the DM rats, the δ 44 Ca/ 42 Ca for the middle of the diaphysis can reflect the Ca isotopes in the bone formed prior to the progression of DM states. Thus, the resulting δ 44 Ca/ 42 Ca values show a clear correlation with bone mineral density (BMD). This can be due to the release of isotopically lighter Ca from the bone to the serum. In the present study, our data demonstrate that the δ 44 Ca/ 42 Ca value for serum can be used as a new biomarker for evaluating changes in bone turnover rate, followed by changes in bone volume.
Barro, Christian; Benkert, Pascal; Disanto, Giulio; Tsagkas, Charidimos; Amann, Michael; Naegelin, Yvonne; Leppert, David; Gobbi, Claudio; Granziera, Cristina; Yaldizli, Özgür; Michalak, Zuzanna; Wuerfel, Jens; Kappos, Ludwig; Parmar, Katrin; Kuhle, Jens
2018-05-30
Neuro-axonal injury is a key factor in the development of permanent disability in multiple sclerosis. Neurofilament light chain in peripheral blood has recently emerged as a biofluid marker reflecting neuro-axonal damage in this disease. We aimed at comparing serum neurofilament light chain levels in multiple sclerosis and healthy controls, to determine their association with measures of disease activity and their ability to predict future clinical worsening as well as brain and spinal cord volume loss. Neurofilament light chain was measured by single molecule array assay in 2183 serum samples collected as part of an ongoing cohort study from 259 patients with multiple sclerosis (189 relapsing and 70 progressive) and 259 healthy control subjects. Clinical assessment, serum sampling and MRI were done annually; median follow-up time was 6.5 years. Brain volumes were quantified by structural image evaluation using normalization of atrophy, and structural image evaluation using normalization of atrophy, cross-sectional, cervical spinal cord volumes using spinal cord image analyser (cordial). Results were analysed using ordinary linear regression models and generalized estimating equation modelling. Serum neurofilament light chain was higher in patients with a clinically isolated syndrome or relapsing remitting multiple sclerosis as well as in patients with secondary or primary progressive multiple sclerosis than in healthy controls (age adjusted P < 0.001 for both). Serum neurofilament light chain above the 90th percentile of healthy controls values was an independent predictor of Expanded Disability Status Scale worsening in the subsequent year (P < 0.001). The probability of Expanded Disability Status Scale worsening gradually increased by higher serum neurofilament light chain percentile category. Contrast enhancing and new/enlarging lesions were independently associated with increased serum neurofilament light chain (17.8% and 4.9% increase per lesion respectively; P < 0.001). The higher the serum neurofilament light chain percentile level, the more pronounced was future brain and cervical spinal volume loss: serum neurofilament light chain above the 97.5th percentile was associated with an additional average loss in brain volume of 1.5% (P < 0.001) and spinal cord volume of 2.5% over 5 years (P = 0.009). Serum neurofilament light chain correlated with concurrent and future clinical and MRI measures of disease activity and severity. High serum neurofilament light chain levels were associated with both brain and spinal cord volume loss. Neurofilament light chain levels are a real-time, easy to measure marker of neuro-axonal injury that is conceptually more comprehensive than brain MRI.
Browne, J L; Schielen, P C J I; Belmouden, I; Pennings, J L A; Klipstein-Grobusch, K
2015-06-01
The objectives of the article is to compare pregnancy-associated plasma protein A (PAPP-A) and free β-subunit of human chorionic gonadotropin (β-hCG) concentrations in dried blood spots (DBSs) with serum of samples obtained from a public hospital in a low-resource setting and to evaluate their stability. Serum and DBS samples were obtained by venipuncture and finger prick from 50 pregnant participants in a cohort study in a public hospital in Accra, Ghana. PAPP-A and β-hCG concentrations from serum and DBS were measured with an AutoDELFIA® (PerkinElmer, PerkinElmer, Turku, Finland) automatic immunoassay. Correlation and Passing-Bablok regression analyses were performed to compare marker levels. High correlation (>0.9) was observed for PAPP-A and β-hCG levels between various sampling techniques. The β-hCG concentration was stable between DBS and serum, PAPP-A concentration consistently lower in DBS. Our findings suggest that β-hCG can be reliably collected from DBS in low-resource tropical settings. The exact conditions of the clinical workflow necessary for reliable PAPP-A measurement in these settings need to be further developed in the future. These findings could have implications for prenatal screening programs feasibility in low-income and middle-income countries, as DBS provides an alternative minimally invasive sampling method, with advantages in sampling technique, stability, logistics, and potential application in low-resource settings. © 2015 John Wiley & Sons, Ltd.
Barranco, Tomas; Tvarijonaviciute, Asta; Tecles, Fernando; Carrillo, Jose M; Sánchez-Resalt, Cristina; Jimenez-Reyes, Pedro; Rubio, Monica; García-Balletbó, Monserrat; Cerón, Jose J; Cugat, Ramon
2018-06-01
The aim of this study was to evaluate changes in the enzymes creatine kinase (CK), lactate dehydrogenase (LDH) and aspartate aminotransferase (AST) in saliva before and after an intense exercise consisting of a futsal match. CK, LDH and AST were analyzed in saliva and serum samples of eleven, injury-free, amateur young men before and 30 minutes, 12 hours and 36 hours after a futsal match. A significant increase in CK, LDH and AST was observed after the game in serum samples. In saliva, although a high interindividual variability was found with some individuals no showing increases, significant increases in CK and LDH were observed after the game. No significant changes were observed in saliva AST after the game. Our study showed for first time that CK and LDH can increase in saliva after an intensive exercise consisting on a futsal match. Results suggest that measurements of CK and LDH in saliva could be potentially used to evaluate possible muscle stress or damage in cases of intensive exercise.
Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin
2018-03-28
Proper management of patients with chronic hepatitis B virus (HBV) infection requires monitoring of plasma or serum HBV DNA levels using a highly sensitive nucleic acid amplification test. Because commercially available assays differ in performance, we compared herein the performance of the Hologic Aptima HBV Quant assay (Aptima) to that of the Roche Cobas TaqMan HBV test for use with the high pure system (HPS/CTM). Assay performance was assessed using HBV reference panels as well as plasma and serum samples from chronically HBV-infected patients. Method correlation, analytical sensitivity, precision/reproducibility, linearity, bias and influence of genotype were evaluated. Data analysis was performed using linear regression, Deming correlation analysis and Bland-Altman analysis. Agreement between the assays for the two reference panels was good, with a difference in assay values vs. target <0.5 log. Qualitative assay results for 159 clinical samples showed good concordance (88.1%; κ=0.75; 95% confidence interval: 0.651-0.845). For the 106 samples quantitated by both assays, viral load results were highly correlated (R=0.92) and differed on average by 0.09 log, with 95.3% of the samples being within the 95% limit of agreement of the assays. Linearity for viral loads 1-7 log was excellent for both assays (R2>0.98). The two assays had similar bias and precision across the different genotypes tested at low viral loads (25-1000 IU/mL). Aptima has a performance comparable with that of HPS/CTM, making it suitable for use for HBV infection monitoring. Aptima runs on a fully automated platform (the Panther system) and therefore offers a significantly improved workflow compared with HPS/CTM.
Deguchi, Matsuo; Kagita, Masanori; Yoshioka, Nori; Tsukamoto, Hiroko; Takao, Miyuki; Tahara, Kazuko; Maeda, Ikuhiro; Hidaka, Yoh; Yamauchi, Satoshi; Kaneko, Atsushi; Miyakoshi, Hideo; Isomura, Mitsuo
2017-10-06
Ongoing efforts in the development of HBsAg detection kits are focused on improving sensitivity and specificity. The purpose of this study was to evaluate an improved, highly sensitive quantitative assay, "Lumipulse HBsAg-HQ", a chemiluminescent enzyme immunoassay designed for a fully automated instrument, the "Lumipulse G1200". Serum samples for reproducibility, dilution, correlation, sensitivity, and specificity studies were obtained from patients at the Osaka University Hospital. Seroconversion and sensitivity panels were purchased from a commercial vender. Subtype, sensitivity panels, and HBsAg recombinant proteins with one or two amino acid substitutions were prepared in-house. The coefficients of variation for the low, medium, and high concentration samples ranged from 1.93 to 2.55%. The HBsAg-HQ reagent for dilution testing showed good linearity in the 0.005-150 HBsAg IU/mL range and no prozone phenomenon. All 102 HBV carrier samples were positive by HBsAg-HQ, while other commercial reagents showed one or more to be negative. In the seroconversion panel, the 14-day blood sample was positive. The sensitivity against HBsAg-HQ "ad" and "ay" subtypes was 0.025 ng/mL. Comparisons among the HBsAg-HQ, HISCL, and Architect HBsAg reagents were performed using the Bland-Altman plot. Specificity for 1000 seronegative individuals was 99.7%. HBsAg-HQ detected 29 positive serum among 12 231 routinely obtained serum samples, which showed concentrations of 0.005-0.05 HBsAg IU/mL. According to these results, the Lumipulse HBsAg-HQ assay, with a highly sensitive limit of detection of 0.005 IU/mL, may facilitate the development of a better management strategy for a considerable proportion of infected patients. © 2017 Wiley Periodicals, Inc.
Nakano, Sachie; Tsukimura, Takahiro; Togawa, Tadayasu; Ohashi, Toya; Kobayashi, Masahisa; Takayama, Katsuyoshi; Kobayashi, Yukuharu; Abiko, Hiroshi; Satou, Masatsugu; Nakahata, Tohru; Warnock, David G; Sakuraba, Hitoshi; Shibasaki, Futoshi
2015-01-01
We developed an immunochromatography-based assay for detecting antibodies against recombinant α-galactosidase A proteins in serum. The evaluation of 29 serum samples from Fabry patients, who had received enzyme replacement therapy with agalsidase alpha and/or agalsidase beta, was performed by means of this assay method, and the results clearly revealed that the patients exhibited the same level of antibodies against both agalsidase alpha and agalsidase beta, regardless of the species of recombinant α-galactosidase A used for enzyme replacement therapy. A conventional enzyme-linked immunosorbent assay supported the results. Considering these, enzyme replacement therapy with agalsidase alpha or agalsidase beta would generate antibodies against the common epitopes in both agalsidase alpha and agalsidase beta. Most of the patients who showed immunopositive reaction exhibited classic Fabry phenotype and harbored gene mutations affecting biosynthesis of α-galactosidase A. As immunochromatography is a handy and simple assay system which can be available at bedside, this assay method would be extremely useful for quick evaluation or first screening of serum antibodies against agalsidase alpha or agalsidase beta in Fabry disease with enzyme replacement therapy.
Kania, Dramane; Truong, Tam Nguyen; Montoya, Ana; Nagot, Nicolas; Van de Perre, Philippe; Tuaillon, Edouard
2015-01-01
Point-of-care testing and diagnosis of HIV acute infections play important roles in preventing transmission, but HIV rapid diagnosis tests have poor capacity to detect early infections. Filter paper can be used for capillary blood collection and HIV testing using 4th generation immunoassays. Antigen/antibody combined immunoassays were evaluated for their capacity to identify early HIV infections using filter paper in comparison with rapid test. Thirty nine serum samples collected from HIV seroconverters were spotted onto filter paper and tested by the Roche Elecsys(®) HIV Combi PT test and the DiaSorin Liaison XL Murex HIV Ab/Ag assay. Fourth generation immunoassays identified 34 out of 39 HIV early infections using dried serum spot, whereas the Determine™ HIV-1/2 rapid test detected 24 out of 39 HIV positive serum (87.2% vs 61.5% respectively, p = 0.009). p24 antigen was detected by the Liaison XL in 19 dried serum samples (48.7%). In the group characterized by a negative western blot, 7 out of 8 (87.5%) and 6 out of 8 (75.0%) samples were found positive for HIV using the Elecsys and the Liaison XL, respectively. None of these eight samples classified in this group of early acute infections were found positive by the rapid test. Fourth generation Ag/Ab immunoassays performed on dried serum spot had good performance for HIV testing during the early phases of HIV infection. This method may be useful to detect HIV early infections in hard-to-reach populations and individuals living in remote areas before rapid tests become positive. Copyright © 2014 Elsevier B.V. All rights reserved.
Park, Jaehyun; Jeon, Byongtae; Kang, Sungki; Oh, Mirae; Kim, Myonghwa; Jang, Seyoung; Park, Pyojam; Kim, Sangwoo; Moon, Sangho
2015-09-01
This study was conducted to investigate changes in blood enzyme parameters and to evaluate the relationship between insulin-like growth factor-1 (IGF-1), antler growth and body weight during the antler growth of sika deer (Cervus nippon). Serum enzyme activity and IGF-1 concentrations were measured in blood samples collected from the jugular and femoral veins at regular intervals during the antler growth period. Blood samples were taken in the morning from fasted stags (n = 12) which were healthy and showed no clinical signs of disease. Alfalfa was available ad libitum and concentrates were given at 1% of body weight to all stags. The experimental diet was provided at 9 am with water available at all times. There were no significant differences in alkaline phosphatase, aspartate aminotransferase, and alanine aminotransferase during antler growth, but alkaline phosphatase concentrations increased with antler growth progression, and the highest alkaline phosphatase concentration was obtained 55 days after antler casting. Serum IGF-1 concentrations measured from blood samples taken from the jugular vein during antler growth, determined that levels of IGF-1 was associated with body weight and antler growth patterns. Serum IGF-1 concentrations were higher at the antler cutting date than other sampling dates. Antler length increased significantly during antler growth (p<0.001), and there was a similar trend to between right and left beams. Body weight increased with antler growth but was not significant. Consequently it appeared that serum alkaline phosphatase concentration was related to antler growth and both antler growth and body weight were associated positively with IGF-1 concentrations during antler growth.
Diesel, Alison; DeBoer, Douglas J
2011-02-01
Feline and canine atopic dermatitis are thought to have a similar immunopathogenesis. As with dogs, detection of allergen-specific IgE in cat serum merely supports a diagnosis of feline atopy based on compatible history, clinical signs and elimination of other pruritic dermatoses. In this study, a rapid screening immunoassay (Allercept(®) E-Screen 2nd Generation; Heska AG, Fribourg, Switzerland; ES2G) was compared with a complete-panel serum allergen-specific IgE assay (Allercept(®); Heska AG; CP) in healthy cats with no history of skin disease and in atopic cats. The latter had no diagnosis of external parasitism, infection, food hypersensitivity or other skin disease explaining their pruritus, and expressed cutaneous reaction patterns typically associated with feline allergic skin disease (head, neck or pinnal pruritus, miliary dermatitis, self-induced alopecia, eosinophilic granuloma complex). The proportion of cats positive on either the ES2G or the CP assays was not significantly different between the atopic and healthy cat groups. There was, however, strong agreement between the results of the ES2G and CP assay; overall, the two tests were in agreement for 43 of 49 (88%) serum samples. There was also strong agreement when individual allergen groups were evaluated (agreement noted: indoor, 41 of 49 samples; grasses/weeds, 37 of 49 samples; and trees, 41 of 49 samples). These results indicate that although neither test is diagnostic for feline atopic dermatitis, the screening assay is beneficial for predicting the results of a complete-panel serum allergen-specific IgE assay in cats. © 2010 The Authors. Journal compilation © 2010 ESVD and ACVD.
Kucherenko, I S; Soldatkin, O O; Lagarde, F; Jaffrezic-Renault, N; Dzyadevych, S V; Soldatkin, A P
2015-11-01
Creatine kinase (CK: adenosine-5-triphosphate-creatine phosphotransferase) is an important enzyme of muscle cells; the presence of a large amount of the enzyme in blood serum is a biomarker of muscular injuries, such as acute myocardial infarction. This work describes a bi-enzyme (glucose oxidase and hexokinase based) biosensor for rapid and convenient determination of CK activity by measuring the rate of ATP production by this enzyme. Simultaneously the biosensor determines glucose concentration in the sample. Platinum disk electrodes were used as amperometric transducers. Glucose oxidase and hexokinase were co-immobilized via cross-linking with BSA by glutaraldehyde and served as a biorecognition element of the biosensor. The biosensor work at different concentrations of CK substrates (ADP and creatine phosphate) was investigated; optimal concentration of ADP was 1mM, and creatine phosphate - 10 mM. The reproducibility of the biosensor responses to glucose, ATP and CK during a day was tested (relative standard deviation of 15 responses to glucose was 2%, to ATP - 6%, to CK - 7-18% depending on concentration of the CK). Total time of CK analysis was 10 min. The measurements of creatine kinase in blood serum samples were carried out (at 20-fold sample dilution). Twentyfold dilution of serum samples was chosen as optimal for CK determination. The biosensor could distinguish healthy and ill people and evaluate the level of CK increase. Thus, the biosensor can be used as a test-system for CK analysis in blood serum or serve as a component of multibiosensors for determination of important blood substances. Determination of activity of other kinases by the developed biosensor is also possible for research purposes. Copyright © 2015 Elsevier B.V. All rights reserved.
Pedrotti Moreira, Fernanda; Borges, Cristiane Jackson; Wiener, Carolina David; da Silva, Paula Moraes; Portela, Luis Valmor; Lara, Diogo R; da Silva, Ricardo Azevedo; de Mattos Souza, Luciano Dias; Jansen, Karen; Oses, Jean Pierre
2018-04-01
Major depressive disorders (MDD) and suicide are significant public health concerns. Recent studies have been demonstrated that alterations in Brain Derived Neurotrophic Factor (BDNF) can be associated with this psychiatric disorders, MDD and suicide. Thus, the aim of this study was to evaluate differences in serum levels in individuals with MDD and with or without suicide attempt (SA), from a population-based sample. This was a paired cross-sectional study nested in a population-based study. The psychopathology screen was performed with the Mini-International Neuropsychiatric Interview (MINI). The total population of the sample consisted of 147 subjects distributed in three groups: 49 healthy controls, 49 subjects with MDD and 49 subjects with MDD and SA (MDD + SA). The BDNF serum levels were significantly reduced in subjects with MDD and MDD + SA compared to the healthy controls. However, there were no significant differences between the MDD and MDD + SA groups with respect to BDNF serum levels. These results suggest that SA did not interfere in the serum levels of BDNF, indicating that this neurotrophin may be related to the diagnosis of MDD and not to suicide attempt. Copyright © 2017 Elsevier B.V. All rights reserved.
Collicutt, Nancy B; Garner, Bridget; Berghaus, Roy D; Camus, Melinda S; Hart, Kelsey
2015-03-01
Although delays between blood sample collection and analysis are common in veterinary medicine, the effect of prolonged serum-clot contact time on serum glucose concentration is not well established and species differences have not been elucidated. The objective was to investigate the effect of storage time and temperature on serum glucose concentration in stored whole blood samples from horse, dog, alpaca, and sturgeon. Whole blood specimens were divided into 7 no-additive tubes and serum was separated from one sample within one hour, serving as the reference sample. The remaining samples were stored at 4°C and 25°C, then centrifuged and serum glucose measured by automated analysis at 2, 4, and 8 hours postcollection. Glucose concentrations were compared using linear mixed models. The decline in serum glucose concentration for all samples stored at 4°C was not statistically significant, except for the 8-hour samples from sturgeon and dog. At 25°C, serum glucose concentration was comparable to reference values at 2 hours in sturgeon and alpaca, but significantly lower at 4 and 8 hours in those species, and at all time points in equine and canine specimens, being most prominent after 8 hours of storage in canine specimens. Storage at 4°C limits serum glucose decline for at least 4 hours in all species tested and up to 8 hours in specimens of horse and alpaca. At 25°C, serum-clot contact time should not exceed 1 hour in equine and canine samples, and 2 hours in specimens from alpaca and sturgeon. © 2014 American Society for Veterinary Clinical Pathology.
Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R.; Fernandes, Daryl L.; Satsangi, Jack; Spencer, Daniel I. R.
2015-01-01
Introduction Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. Methods 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. Results There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. Conclusions The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures. PMID:25831126
Ventham, Nicholas T; Gardner, Richard A; Kennedy, Nicholas A; Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R; Fernandes, Daryl L; Satsangi, Jack; Spencer, Daniel I R
2015-01-01
Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures.
Panyasing, Y; Goodell, C K; Wang, C; Kittawornrat, A; Prickett, J R; Schwartz, K J; Ballagi, A; Lizano, S; Zimmerman, J J
2014-04-01
In commercial swine populations, influenza is an important component of the porcine respiratory disease complex (PRDC) and a pathogen with major economic impact. Previously, a commercial blocking ELISA (FlockChek(™) Avian Influenza Virus MultiS-Screen(®) Antibody Test Kit, IDEXX Laboratories, Inc., Westbrook, ME, USA) designed to detect influenza A nucleoprotein (NP) antibodies in avian serum was shown to accurately detect NP antibodies in swine serum. The purpose of this study was to determine whether this assay could detect NP antibodies in swine oral fluid samples. Initially, the procedure for performing the NP-blocking ELISA on oral fluid was modified from the serum testing protocol by changing sample dilution, sample volume, incubation time and incubation temperature. The detection of NP antibody was then evaluated using pen-based oral fluid samples (n = 182) from pigs inoculated with either influenza A virus subtype H1N1 or H3N2 under experimental conditions and followed for 42 days post inoculation (DPI). NP antibodies in oral fluid were detected from DPI 7 to 42 in all inoculated groups, that is, the mean sample-to-negative (S/N) ratio of influenza-inoculated pigs was significantly different (P < 0.0001) from uninoculated controls (unvaccinated or vaccinated-uninoculated groups) through this period. Oral fluid versus serum S/N ratios from the same pen showed a correlation of 0.796 (Pearson's correlation coefficient, P < 0.0001). The results showed that oral fluid samples from influenza virus-infected pigs contained detectable levels of NP antibodies for ≥42 DPI. Future research will be required to determine whether this approach could be used to monitor the circulation of influenza virus in commercial pig populations. © 2012 Blackwell Verlag GmbH.
Individualized correction of insulin measurement in hemolyzed serum samples.
Wu, Zhi-Qi; Lu, Ju; Chen, Huanhuan; Chen, Wensen; Xu, Hua-Guo
2017-06-01
Insulin measurement plays a key role in the investigation of patients with hypoglycemia, subtype classification of diabetes mellitus, insulin resistance, and impaired beta cell function. However, even slight hemolysis can negatively affect insulin measurement due to RBC insulin-degrading enzyme (IDE). Here, we derived and validated an individualized correction equation in an attempt to eliminate the effects of hemolysis on insulin measurement. The effects of hemolysis on insulin measurement were studied by adding lysed self-RBCs to serum. A correction equation was derived, accounting for both percentage and exposure time of hemolysis. The performance of this individualized correction was evaluated in intentionally hemolyzed samples. Insulin concentration decreased with increasing percentage and exposure time of hemolysis. Based on the effects of hemolysis on insulin measurement of 17 donors (baseline insulin concentrations ranged from 156 to 2119 pmol/L), the individualized hemolysis correction equation was derived: INS corr = INS meas /(0.705lgHb plasma /Hb serum - 0.001Time - 0.612). This equation can revert insulin concentrations of the intentionally hemolyzed samples to values that were statistically not different from the corresponding insulin baseline concentrations (p = 0.1564). Hemolysis could lead to a negative interference on insulin measurement; by individualized hemolysis correction equation for insulin measurement, we can correct and report reliable serum insulin results for a wide range of degrees of sample hemolysis. This correction would increase diagnostic accuracy, reduce inappropriate therapeutic decisions, and improve patient satisfaction with care.
Hart, Leslie B.; Wells, Randall S.; Kellar, Nick; Balmer, Brian C.; Hohn, Aleta A.; Lamb, Stephen V.; Rowles, Teri; Zolman, Eric S.; Schwacke, Lori H.
2015-01-01
Inshore common bottlenose dolphins (Tursiops truncatus) are exposed to a broad spectrum of natural and anthropogenic stressors. In response to these stressors, the mammalian adrenal gland releases hormones such as cortisol and aldosterone to maintain physiological and biochemical homeostasis. Consequently, adrenal gland dysfunction results in disruption of hormone secretion and an inappropriate stress response. Our objective herein was to develop diagnostic reference intervals (RIs) for adrenal hormones commonly associated with the stress response (i.e., cortisol, aldosterone) that account for the influence of intrinsic (e.g., age, sex) and extrinsic (e.g., time) factors. Ultimately, these reference intervals will be used to gauge an individual’s response to chase-capture stress and could indicate adrenal abnormalities. Linear mixed models (LMMs) were used to evaluate demographic and sampling factors contributing to differences in serum cortisol and aldosterone concentrations among bottlenose dolphins sampled in Sarasota Bay, Florida, USA (2000–2012). Serum cortisol concentrations were significantly associated with elapsed time from initial stimulation to sample collection (p<0.05), and RIs were constructed using nonparametric methods based on elapsed sampling time for dolphins sampled in less than 30 minutes following net deployment (95% RI: 0.91–4.21 µg/dL) and following biological sampling aboard a research vessel (95% RI: 2.32–6.68 µg/dL). To examine the applicability of the pre-sampling cortisol RI across multiple estuarine stocks, data from three additional southeast U.S. sites were compared, revealing that all of the dolphins sampled from the other sites (N = 34) had cortisol concentrations within the 95th percentile RI. Significant associations between serum concentrations of aldosterone and variables reported in previous studies (i.e., age, elapsed sampling time) were not observed in the current project (p<0.05). Also, approximately 16% of Sarasota Bay bottlenose dolphin aldosterone concentrations were below the assay’s detection limit (11 pg/mL), thus hindering the ability to derive 95th percentile RIs. Serum aldosterone concentrations from animals sampled at the three additional sites were compared to the detection limit, and the proportion of animals with low aldosterone concentrations was not significantly different than an expected prevalence of 16%. Although this study relied upon long-term, free-ranging bottlenose dolphin health data from a single site, the objective RIs can be used for future evaluation of adrenal function among individuals sampled during capture-release health assessments. PMID:25993341
Ergünay, Koray; Özkul, Aykut
2011-04-01
West Nile virus (WNV) infections may trigger febrile conditions and/or neuroinvasive disease in a portion of the exposed individuals. Serosurveillance data from various regions of Turkey indicate WNV activity. The aim of this study was to confirm the antibody specificity of the serum samples via virus neutralization assay, previously reported to be reactive for WNV IgM. The samples originated from two individuals with the preliminary diagnosis of aseptic meningitis/encephalitis of unknown etiology in 2009 and had been classified as probable WNV infections. Cerebrospinal fluid and sera samples of these patients had been evaluated as negative for WNV RNA and IgG antibodies. Only one serum sample could be included in the neutralization assay due to the limited amounts in the current investigation. The sample was observed as positive in dilutions of 1/20 and 1/40, thus confirming the diagnosis of WNV-related central nervous system infection in a 62 year-old female patient from Ankara, Central Anatolia, Turkey.
Low vitamin D status and suicide: a case-control study of active duty military service members.
Umhau, John C; George, David T; Heaney, Robert P; Lewis, Michael D; Ursano, Robert J; Heilig, Markus; Hibbeln, Joseph R; Schwandt, Melanie L
2013-01-01
Considering that epidemiological studies show that suicide rates in many countries are highest in the spring when vitamin D status is lowest, and that low vitamin D status can affect brain function, we sought to evaluate if a low level of 25-hydroxyvitamin D [25(OH)D] could be a predisposing factor for suicide. We conducted a prospective, nested, case-control study using serum samples stored in the Department of Defense Serum Repository. Participants were previously deployed active duty US military personnel (2002-2008) who had a recent archived serum sample available for analysis. Vitamin D status was estimated by measuring 25(OH) D levels in serum samples drawn within 24 months of the suicide. Each verified suicide case (n = 495) was matched to a control (n = 495) by rank, age and sex. We calculated odds ratio of suicide associated with categorical levels (octiles) of 25(OH) D, adjusted by season of serum collection. More than 30% of all subjects had 25(OH)D values below 20 ng/mL. Although mean serum 25(OH)D concentrations did not differ between suicide cases and controls, risk estimates indicated that subjects in the lowest octile of season-adjusted 25(OH)D (<15.5 ng/mL) had the highest risk of suicide, with subjects in the subsequent higher octiles showing approximately the same level of decreased risk (combined odds ratio compared to lowest octile = 0.49; 95% C.I.: 0.315-0.768). Low vitamin D status is common in active duty service members. The lowest 25(OH)D levels are associated with an increased risk for suicide. Future studies could determine if additional sunlight exposure and vitamin D supplementation might reduce suicide by increasing 25(OH) D levels.
IL8 and IL16 levels indicate serum and plasma quality.
Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay
2018-02-09
Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.
Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.
Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H
2013-10-01
Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.
Morandi, Pierre-Alain; Schockmel, Gérard A.; Yerly, Sabine; Burgisser, Philippe; Erb, Peter; Matter, Lukas; Sitavanc, Radan; Perrin, Luc
1998-01-01
A total of 234 pools were prepared from 10,692 consecutive serum samples negative for antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 collected at five virological laboratories (average pool size, 45 serum samples). Pools were screened for the presence of HIV-1 RNA by a modified commercial assay (Amplicor HIV-1 Monitor test) which included an additional polyethylene glycol (PEG) precipitation step prior to purification of viral RNA (PEG Amplicor assay). The sensitivity of this assay for HIV-1 RNA detection in individual serum samples within pools matches that of standard commercial assays for individual serum samples, i.e., 500 HIV-1 RNA copies per ml. Five pools were identified as positive, and each one contained one antibody-negative, HIV-1 RNA-positive serum sample, corresponding to an average of 1 infected sample per 2,138 serum samples. Retrospective analysis revealed that the five HIV-1 RNA-positive specimens originated from individuals who had symptomatic primary HIV-1 infection at the time of sample collection and who were also positive for p24 antigenemia. We next assessed the possibility of performing the prepurification step by high-speed centrifugation (50,000 × g for 80 min) of 1.5-ml pools containing 25 μl of 60 individual serum samples, of which only 1 contained HIV-1 RNA (centrifugation Amplicor assay). The sensitivity of this assay also matches the sensitivities of standard commercial assays for HIV-1 RNA detection in individual serum samples. The results demonstrate that both assays with pooled sera can be applied to the screening of large numbers of serum samples in a time- and cost-efficient manner. PMID:9620372
Kocijancic, Marija; Cargonja, Jelena; Delic-Knezevic, Alma
2014-01-01
Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer(®) Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum separation. Our aim was to evaluate the comparability of routine chemistry parameters in BD Vacutainer(®) RST blood collection tube in reference with the BD Vacutainer(®) Serum Separating Tubes II Advance Tube (SST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA). Blood specimens were collected from 90 participants for evaluation on its results, clotting time and stability study of six routine biochemistry parameters: glucose (Glu), aspartate aminotransferase (AST), alanine aminotransferase (ALT), calcium (Ca), lactate dehidrogenase (LD) and potassium (K) measured with Olympus AU2700 analyzer (Beckman Coulter, Tokyo, Japan). The significance of the differences between samples was assessed by paired t-test or Wilcoxon Matched-Pairs Rank test after checking for normality. Clotting process was significantly shorter in the RSTs compared to SSTs (2.49 min vs. 19.47 min, respectively; P < 0.001). There was a statistically significant difference between the RST and SST II tubes for glucose, calcium and LD (P < 0.001). Differences for glucose and LD were also clinically significant. Analyte stability studies showed that all analytes were stable for 24 h at 4 °C. Most results (except LD and glucose) from RST are comparable with those from SST. In addition, RST tube provides shorter clotting time.
Thiazide increases serum calcium in anuric patients: the role of parathyroid hormone.
Vasco, Raquel F V; Reis, Eduardo T; Moyses, Rosa M A; Elias, Rosilene M
2017-12-01
We evaluated the effect of hydrochlorothiazide in a sample of anuric patients on hemodialysis and found an increase in serum calcium, which occurred only in those with parathyroid hormone >300 pg/ml. This finding highlights the extra-renal effect of this diuretic and a possible role of parathyroid hormone in the mechanism. Thiazide diuretics are commonly used in patients with chronic kidney disease to treat hypertension. Their effects on calcium and bone metabolism are not well established, once calciuria may not fully explain levels of calcium and parathyroid hormone (PTH) in this population. A previous study has suggested that thiazides require the presence of PTH as a permissive condition for its renal action. In anuric patients, however, the role of PTH, if any, in the thiazide effect is unknown. To assess thiazide extra renal effect on serum calcium and whether such an effect is reliant on PTH, hydrochlorothiazide (HCTZ) 100 mg was given orally once a day to a sample of 19 anuric patients on hemodialysis for 2 weeks. Laboratories' analyses were obtained in three phases: baseline, after diuretic use, and after a 2-week washout phase. We demonstrated that serum calcium (Ca) increased in ten patients (52.6%) after HCTZ use, returning to previous levels after the washout period. Out of the 19 patients, ten presented PTH ≥ 300 pg/ml, and Ca has increased in eight of them, whereas in the other nine patients with PTH < 300 pg/ml, serum Ca has increased only in two individuals (RR risk of increase Ca 3.9; p = 0.012). HCTZ was capable of increasing serum Ca in a sample of anuric patients on hemodialysis and seems this effect is highly dependent on PTH levels. Caution is required while interpreting this result, as the small sample size might implicate in a finding caused by chance.
Gottumukkala, Vijay; Heinrich, Tobias K.; Baker, Amanda; Dunning, Patricia; Fahey, Frederick H; Treves, S. Ted; Packard, Alan B.
2010-01-01
Introduction Fluorine-18-labeled rhodamine B was developed as a potential PET tracer for the evaluation of myocardial perfusion, but preliminary studies in mice showed no accumulation in the heart suggesting that it was rapidly hydrolyzed in vivo in mice. A study was, therefore, undertaken to further evaluate this hypothesis. Methods [18F]Fluoroethylrhodamine B was equilibrated for 2 h at 37 °C in human, rat and mouse serum and in PBS. Samples were removed periodically and assayed by HPLC. Based on the results of the stability study, microPET imaging and a biodistribution study were carried out in rats. Results In vitro stability studies demonstrated that [18F]fluoroethylrhodamine B much more stable in rat and human sera than in mouse serum. After 2 h, the compound was >80% intact in rat serum but <30% intact in mouse serum. The microPET imaging and biodistribution studies in rats confirmed this result showing high and persistent tracer accumulation in the myocardium compared with the absence of uptake by the myocardium in mice thereby validating our original hypothesis that 18F-labeled rhodamines should accumulate in the heart. Conclusions [18F]Fluoroethyl rhodamine B is more stable in rat and human sera than it is in mouse serum. This improved stability is demonstrated by the high uptake of the tracer in the rat heart in comparison to the absence of visible uptake in the mouse heart. These observations suggest that 18F-labeled rhodamines are promising candidates for more extensive evaluation as PET tracers for the evaluation of myocardial perfusion. PMID:20346876
Houser, Dorian S; Champagne, Cory D; Jensen, Eric D; Smith, Cynthia R; Cotte, Lara S; Meegan, Jenny M; Booth, Rebecca K; Wasser, Samuel K
2017-07-15
OBJECTIVE To evaluate the impact of oral megestrol acetate (MA) administration on adrenal function in male bottlenose dolphins (Tursiops truncatus). DESIGN Serial cross-sectional study. ANIMALS 8 adult male dolphins, all of which were receiving MA at various daily doses (range, 0 to 60 mg, PO) for the control of reproductive behavior. PROCEDURES Blood samples were collected every 2 weeks for 1 year from dolphins trained to voluntarily provide them. Cortisol, ACTH, and other hormone concentrations were measured in serum or plasma via radioimmunoassay or ELISA. Fecal samples, also provided by dolphins voluntarily, were assayed for glucocorticoid metabolite concentrations. Effects of daily MA dose on hormone concentrations were evaluated. RESULTS Daily MA doses as low as 10 mg strongly suppressed cortisol secretion in nearly all dolphins, and except for a single measurement, no dolphin had measurable serum concentrations at doses ≥ 20 mg. Variations in serum cortisol concentration were unrelated to season but were directly related to ACTH concentrations, suggesting primary effects upstream of the adrenal gland. Cessation of MA administration resulted in almost immediate restoration of measurable serum cortisol concentrations, although concentrations continued to rise in a few dolphins over the following weeks to months. CONCLUSIONS AND CLINICAL RELEVANCE Caution should be exercised when administering MA to control reproductive behavior in male dolphins. Because the hypothalamic-pituitary-adrenal axis appeared to be sensitive to even small doses of MA in dolphins, duration of treatment may be the most critical consideration.
Yoshida, Taisuke; Ishikawa, Masatomo; Niitsu, Tomihisa; Nakazato, Michiko; Watanabe, Hiroyuki; Shiraishi, Tetsuya; Shiina, Akihiro; Hashimoto, Tasuku; Kanahara, Nobuhisa; Hasegawa, Tadashi; Enohara, Masayo; Kimura, Atsushi; Iyo, Masaomi; Hashimoto, Kenji
2012-01-01
Meta-analyses have identified serum levels of brain-derived neurotrophic factor (BDNF) as a potential biomarker for major depressive disorder (MDD). However, at the time, commercially available human ELISA kits are unable to distinguish between proBDNF (precursor of BDNF) and mature BDNF because of limited BDNF antibody specificity. In this study, we examined whether serum levels of proBDNF, mature BDNF, and matrix metalloproteinase-9 (MMP-9), which converts proBDNF to mature BDNF, are altered in patients with MDD. Sixty-nine patients with MDD and 78 age- and gender-matched healthy subjects were enrolled. Patients were evaluated using 17 items on the Structured Interview Guide for the Hamilton Depression Rating Scale. Cognitive impairment was evaluated using the CogState battery. Serum levels of proBDNF, mature BDNF, and MMP-9 were measured using ELISA kits. Serum levels of mature BDNF in patients with MDD were significantly lower than those of normal controls. In contrast, there was no difference in the serum levels of proBDNF and MMP-9 between patients and normal controls. While neither proBDNF nor mature BDNF serum levels was associated with clinical variables, there were significant correlations between MMP-9 serum levels and the severity of depression, quality of life scores, and social function scores in patients. These findings suggest that mature BDNF may serve as a biomarker for MDD, and that MMP-9 may play a role in the pathophysiology of MDD. Further studies using larger sample sizes will be needed to investigate these results.
Comparison of Schmallenberg virus antibody levels detected in milk and serum from individual cows.
Daly, Janet M; King, Barnabas; Tarlinton, Rachael A; Gough, Kevin C; Maddison, Ben C; Blowey, Roger
2015-03-11
Schmallenberg virus (SBV) is a recently emerged virus of ruminants in Europe. Enzyme-linked immunosorbent assays (ELISA) are commonly used to detect SBV-specific antibodies in bulk tank milk samples to monitor herd exposure to infection. However, it has previously been shown that a bulk tank milk sample can test positive even though the majority of cows within the herd are seronegative for SBV antibodies. Development of a pen-side test to detect antibodies in individual milk samples would potentially provide a cheaper test (for which samples are obtained non-invasively) than testing individual serum samples by ELISA. Therefore, the aim of this study was to investigate the agreement between antibody levels measured in milk and serum. Corresponding milk and serum samples from 88 cows in two dairy herds in the UK were tested for presence of immunoglobulin G antibodies to SBV using a commercially-available indirect ELISA. A serum neutralisation test (NT) was also performed as a gold standard assay. The ELISA values obtained for the bulk tank milk samples corresponded with the mean values for individual milk samples from each herd (bulk tank milk values were 58% and 73% and mean individual milk values 50% and 63% for herds A and B, respectively). Of the 88 serum samples tested in the NT, 82 (93%) were positive. Although at higher antibody levels, the ELISA values tended to be higher for the individual milk samples than for the corresponding serum samples, the positive predictive value for milk samples was 98% and for serum samples 94%. The serum ELISA was more likely to give false positive results around the lower cut-off value of the assay. The results indicate that testing of individual milk samples for antibodies against SBV by ELISA could be used to inform decisions in the management of dairy herds such as which, if any, animals to vaccinate.
Skrzydlewska, Elzbieta; Sulkowska, Mariola; Wincewicz, Andrzej; Koda, Mariusz; Sulkowski, Stanislaw
2005-01-01
AIM: Proteolytic degradation of the extracellular matrix facilitates cancer invasion and promotes metastasis. The study aims at evaluation of preoperative and postoperative serum cathepsins B and D levels in correlation with selected anatomoclinical features of colorectal cancer. METHODS: Blood samples were collected from 63 colorectal cancer patients before curative operation of the tumor 10 d later. Blood that was obtained from 20 healthy volunteers, served as a control. The activity of cathepsin B was measured with Bz-DL-arginine-pNA as a substrate at pH 6.0, while cathepsin D activity was determined with urea-denatured hemoglobin (pH 4.0). RESULTS: The preoperative and postoperative activities of cathepsin B were significantly (P < 0.00001) lower in serum of colorectal cancer patients than in control group. However, postoperative values of this protease were significantly increased in comparison with preoperative ones (P = 0.031). Activity of cathepsin D appeared to be significantly higher in colorectal cancer sera (P < 0.00001) compared with controls. No statistically significant differences between preoperative and postoperative activity of cathepsin D were noted (P = 0.09). We revealed a strong linkage of cathepsins’ levels with lymph node status and pT stage of colorectal cancer. CONCLUSION: Blood serum activities of cathepsin B and D depend on the time of sampling, tumor size and lymph node involvement. Significantly, increased activity of cathepsin D could indicate a malignant condition of the large intestine. In our work, the serum postoperative decrease of cathepsin B activity appears as an obvious concomitant of local lymph node metastasis-the well-known clinicopathological feature of poor prognosis. PMID:16015694
Fosse, J; Laroche, M; Rossero, A; Fédérighi, M; Seegers, H; Magras, C
2006-09-01
Campylobacter is one of the main causes of human foodborne bacterial disease associated with meat consumption in developed countries. Therefore, the most effective approach for recovery and detection of Campylobacter from meat should be determined. Two hundred ninety pork skin and chine samples were inoculated with Campylobacter jejuni NCTC 11168 and two strains of Campylobacter coli. Campylobacter cells were then recovered from suspensions and enumerated by direct plating. Campylobacter recovery was evaluated by comparing results for two methods of sample collection (swabbing and mechanical pummeling) and three recovery fluids (peptone water, 5% glucose serum, and demineralized water). End-point multiplex PCR was performed to evaluate the compatibility of the recovery fluids with direct PCR detection techniques. Mean recovery ratios differed significantly between pork skin and chine samples. Ratios were higher for mechanical pummeling (0.53 for pork skin and 0.49 for chine) than for swabbing (0.31 and 0.13, respectively). For pork skin, ratios obtained with peptone water (0.50) and with glucose serum (0.55) were higher than those obtained with demineralized water (0.16). Significant differences were not observed for chine samples. Direct multiplex PCR detection of Campylobacter was possible with pork skin samples. The tools for Campylobacter recovery must be appropriate for the meat matrix to be evaluated. In this study, less than 66% of inoculated Campylobacter was recovered from meat. This underestimation must be taken into account for quantitative risk analysis of Campylobacter infection.
Mosquim, Victor; Sales Peres, Matheus de Carvalho; Ceneviva, Reginaldo; Chaim, Elinton Adami
2016-01-01
Society has changed its own lifestyle, specially its eating habits and physical activities, leading to excessive weight and a sedentary behavior, which has contributed to obesity increase. Bariatric surgery is the most effective treatment to obesity, allowing weight loss and its maintenance. However, it has been related high levels of iron deficiency after surgery. A person’s nutritional status might be affected by total or partial tooth loss. The aim of this longitudinal prospective cohort study was to evaluate the levels of serum ferritin before and after bariatric surgery and to identify if there is a relation with tooth loss. The sample was composed of 50 patients selected and assisted at Amaral Carvalho Hospital, located in Jaú city, Brazil. The use and necessity of prosthesis, dental absence or presence, and serum ferritin dosage were evaluated. Student’s t test, Univariate analysis, Chi-square and Odds Ratio were adopted (p<0.05). There was no significant difference regarding the serum ferritin levels between dentate and edentulous patients prior to surgery (p = 0.436). After surgery, the serum ferritin levels were higher in edentulous patients (prosthesis users) when compared to the pre-surgical levels, and the post-surgical levels presented significant difference regarding the dentate patients (p = 0.024). It can be concluded that rehabilitated patients in postoperative period showed better levels of serum ferritin after surgical intervention. PMID:27695053
Foratori, Gerson Aparecido; Andrade, Francisco Juliherme Pires de; Mosquim, Victor; Sales Peres, Matheus de Carvalho; Ceneviva, Reginaldo; Chaim, Elinton Adami; Sales Peres, Silvia Helena de Carvalho
2016-01-01
Society has changed its own lifestyle, specially its eating habits and physical activities, leading to excessive weight and a sedentary behavior, which has contributed to obesity increase. Bariatric surgery is the most effective treatment to obesity, allowing weight loss and its maintenance. However, it has been related high levels of iron deficiency after surgery. A person's nutritional status might be affected by total or partial tooth loss. The aim of this longitudinal prospective cohort study was to evaluate the levels of serum ferritin before and after bariatric surgery and to identify if there is a relation with tooth loss. The sample was composed of 50 patients selected and assisted at Amaral Carvalho Hospital, located in Jaú city, Brazil. The use and necessity of prosthesis, dental absence or presence, and serum ferritin dosage were evaluated. Student's t test, Univariate analysis, Chi-square and Odds Ratio were adopted (p<0.05). There was no significant difference regarding the serum ferritin levels between dentate and edentulous patients prior to surgery (p = 0.436). After surgery, the serum ferritin levels were higher in edentulous patients (prosthesis users) when compared to the pre-surgical levels, and the post-surgical levels presented significant difference regarding the dentate patients (p = 0.024). It can be concluded that rehabilitated patients in postoperative period showed better levels of serum ferritin after surgical intervention.
Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin
2014-01-01
Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.
Dukić, Lora; Šimundić, Ana-Maria; Malogorski, Davorin
2014-01-01
Introduction: Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Materials and methods: Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Results: Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = −0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Conclusion: Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration. PMID:24627723
He, Wei-Tao; Liang, Bo-Cheng; Shi, Zhen-Yu; Li, Xu-Yun; Li, Chun-Wen; Shi, Xiao-Lin
2016-01-01
The present study aimed at investigating the weak cation magnetic separation technology and matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) in screening serum protein markers of osteopenia from ten postmenopausal women and ten postmenopausal women without osteopenia as control group, to find a new method for screening biomarkers and establishing a diagnostic model for primary type I osteoporosis. Serum samples were collected from postmenopausal women with osteopenia and postmenopausal women with normal bone mass. Proteins were extracted from serum samples by weak cation exchange magnetic beads technology, and mass spectra acquisition was done by MALDI-TOF-MS. The visualization and comparison of data sets, statistical peak evaluation, model recognition, and discovery of biomarker candidates were handled by the proteinchip data analysis system software(ZJU-PDAS). The diagnostic models were established using genetic arithmetic based support vector machine (SVM). The SVM result with the highest Youden Index was selected as the model. Combinatorial Peaks having the highest accuracy in distinguishing different samples were selected as potential biomarker. From the two group serum samples, a total of 133 differential features were selected. Ten features with significant intensity differences were screened. In the pair-wise comparisons, processing of MALDI-TOF spectra resulted in the identification of ten differential features between postmenopausal women with osteopenia and postmenopausal women with normal bone mass. The difference of features by Youden index showed that the highest features had a mass to charge ratio of 1699 and 3038 Da. A diagnosis model was established with these two peaks as the candidate marker, and the specificity of the model is 100 %, the sensitivity was 90 % by leave-one-out cross validation test. The two groups of specimens in SVM results on the scatter plot could be clearly distinguished. The peak with m/z 3038 in the SVM model was suggested as Secretin by TagIdent tool. To provide further validation, the secretin levels in serum were analyzed using enzyme-linked immunosorbent assays that is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of secretin in human serum.
Single point estimation of phenytoin dosing: a reappraisal.
Koup, J R; Gibaldi, M; Godolphin, W
1981-11-01
A previously proposed method for estimation of phenytoin dosing requirement using a single serum sample obtained 24 hours after intravenous loading dose (18 mg/Kg) has been re-evaluated. Using more realistic values for the volume of distribution of phenytoin (0.4 to 1.2 L/Kg), simulations indicate that the proposed method will fail to consistently predict dosage requirements. Additional simulations indicate that two samples obtained during the 24 hour interval following the iv loading dose could be used to more reliably predict phenytoin dose requirement. Because of the nonlinear relationship which exists between phenytoin dose administration rate (RO) and the mean steady state serum concentration (CSS), small errors in prediction of the required RO result in much larger errors in CSS.
Humann-Ziehank, Esther; Tegtmeyer, Philip C; Seelig, Bjoern; Roehrig, Petra; Ganter, Martin
2013-11-19
This study was performed to demonstrate the widespread distribution and severity of selenium (Se) deficiency in sheep flocks and to evaluate the impact of influencing factors. In 150 flocks, ten serum samples of adult ewes were analysed for Se concentration. The farmers were interviewed concerning flock size, provision of mineral supplement, predominant form of husbandry (stationary fenced pasture/transhumance), predominant form of water provision (tap water/well/surface water) and predominant soil (sandy, silty/loamy, clay) in the area. The location of the flock was recorded as well as the production stage/season at the time of sampling. Intra-group variation and the validity to analyse pooled samples were tested. Pools of five samples correlated well with the mean of individually analysed samples. The intra-group range of serum Se concentration varied enormously (mean 45.4 ± 18.8 μg Se/l). About 60% of the flocks showed mean serum Se concentrations below 80 μg/l, 37.4% were below 60 μg Se/l, representing a Se deficient stage. Using mineral supplement in general was no key factor for Se status. Stationary flocks on fenced pasture had constantly higher mean serum Se concentrations during breeding (outdoors, August-November), lambing (mainly indoors, December-March) and lactation (outdoors, April-July), whereas flocks practising transhumance had significantly lower Se status, except during lambing. There was no significant correlation between the soil type and the Se status, but flocks in Southern Germany tend to show a lower Se status compared to Central and Northern Germany. Increasing flock size was associated with lower mean serum Se concentrations. In stationary flocks only, the use of surface water was accompanied by significantly lower Se status. Se deficiency is widespread in German sheep flocks. More than one third of the flocks showed Se deficiency, indicating the need to optimise the nutritional management. Factors raising suspicion of Se deficiency are large flocks, transhumance during lactation and the breeding season as well as surface water provision in stationary flocks.
Kumar, Jyoti S; Saxena, Divyasha; Parida, Manmohan
2014-01-01
The recent outbreaks of West Nile Virus (WNV) in the Northeastern American continents and other regions of the world have made it essential to develop an efficient protocol for surveillance of WN virus. Nucleic acid based techniques like, RT-PCR have the advantage of sensitivity, specificity and rapidity. A one step single tube Env gene specific real-time RT-PCR was developed for early and reliable clinical diagnosis of WNV infection in clinical samples. The applicability of this assay for clinical diagnosis was validated with 105 suspected acute-phase serum and plasma samples from the recent epidemic of mysterious fever in Tamil Nadu, India in 2009-10. The comparative evaluation revealed the higher sensitivity of real-time RT-PCR assay by picking up 4 additional samples with low copy number of template in comparison to conventional RT-PCR. All the real-time positive samples further confirmed by CDC reported TaqMan real-time RT-PCR and quantitative real-time RT-PCR assays for the simultaneous detection of WNV lineage 1 and 2 strains. The quantitation of the viral load samples was done using a standard curve. These findings demonstrated that the assay has the potential usefulness for clinical diagnosis due to detection and quantification of WNV in acute-phase patient serum samples. Copyright © 2014 Elsevier Ltd. All rights reserved.
Analysis and stability of retinol in plasma.
Peng, Y M; Xu, M J; Alberts, D S
1987-01-01
A simple, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the simultaneous measurement of retinol (ROH), 13-cis-retinoic acid (13-cRA), and 4-oxo-13-cRA. The average recovery of ROH from serum or plasma was 95%, and the precision of the assay was less than 5%. With this HPLC method, a series of studies was carried out to evaluate the stability of ROH in various matrices. ROH was stable under our HPLC assay conditions as well as in plasma- and in serum-enriched culture media; however, ROH was not stable in aqueous matrices. Serum or heparinized plasma may be routinely used for measurement of ROH concentrations, providing EDTA, oxalate, and citrate are not used as anticoagulants. Because of ROH stability, blood samples can be kept on ice in the dark for at least 24 hours prior to separation of plasma. In addition, plasma samples containing ROH can be stored for up to 1 year at -20 degrees C without loss of stability.
Kobayashi, Tsuneo
2018-03-01
Diagnosis using a specific tumor marker is difficult because the sensitivity of this detection method is under 20%. Herein, a tumor marker combination assay, combining growth-related tumor marker and associated tumor marker (Cancer, 73(7), 1994), was employed. This double-blind tumor marker combination assay (TMCA) showed 87.5% sensitivity as the results, but a low specificity, ranging from 30 to 76%. To overcome this low specificity, we exploited complex markers, a multivariate analysis and serum fractionation by biochemical biopsy. Thus, in this study, a combination of new techniques was used to re-evaluate these serum samples. Three serum panels, containing 90, 120, and 97 samples were obtained from the Mayo Clinic. The final results showed 80-90% sensitivity, 84-85% specificity, and 83-88% accuracy. We demonstrated a notable tumor marker combination assay with high accuracy. This TMCA should be applicable for primary cancer detection and recurrence prevention. © 2018 The Author. Cancer Medicine published by John Wiley & Sons Ltd.
Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong
2017-01-01
Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime, laboratorians must remain alert to the negative interference by rheumatoid factor, and in some cases, pretreat rheumatoid factor-positive samples with blocking or absorbing reagents.
Blood creatinine level in postmortem cases.
Nishida, Atsushi; Funaki, Hironao; Kobayashi, Masaki; Tanaka, Yuka; Akasaka, Yoshihisa; Kubo, Toshikazu; Ikegaya, Hiroshi
2015-05-01
Blood chemical analysis for the diagnosis of diseases in forensic cases should be conducted in the same way as for clinical cases. However, it is sometimes difficult to obtain serum samples in forensic cases because of postmortem changes such as hemolysis and putrefaction. This study aimed to evaluate renal function in postmortem cases by blood creatinine analysis. The blood creatinine level was measured by high performance liquid chromatography (HPLC) using whole blood samples taken from 77 postmortem cases, and the relationships between blood creatinine level, postmortem interval, and cause of death were examined. The median blood creatinine level was found to be 1.15 mg/dL, with no significant differences between blood samples taken from different parts of the body. The blood creatinine level was stable for 3 days after death and gradually increased after that period, in line with a previous study using enzymatic analysis that found the serum creatinine level was stable in the early postmortem period. The blood creatinine level was high in the cases of blunt injury, intoxication, and in deaths caused by fire. This was considered to reflect acute renal dysfunction. However, the postmortem blood creatinine level remained higher than the clinical normal value despite omitting cases with renal dysfunction from the analysis. Therefore, we next investigated the change in postmortem creatinine levels in mice and found that the blood creatinine level increased with the emergence of rigor mortis. Our findings indicate that HPLC is useful in the postmortem evaluation of renal function even in the cases where serum cannot be obtained. However, the presence of rigor mortis should be considered in the evaluation of blood creatinine values. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Meza-Herrera, Cesar A; Hernández-Valenzuela, Luis C; González-Bulnes, Antonio; Tena-Sempere, Manuel; Abad-Zavaleta, Jose; Salinas-Gonzalez, Homero; Mellado, Miguel; Veliz-Deras, Francisco
2011-11-01
The effect of betacarotene (BC) supplementation on the onset of puberty and serum insulin levels in goats was evaluated in the study. In June, prepuberal goats (n=17; 3 months old; 7/8 Saanen-Alpine; 26° NL) were randomly assigned to one of two groups: 1/ betacarotene group supplemented daily with 50 mg of BC (n=9; live weight [LW]: 17.3±1.0 kg; body condition score [BCS]: 3.34±0.12) or 2/ control group (CONT; n=8; LW:16.1±1.0 kg; BCS=3.17±0.12). From June to November, an intermittent blood sampling was performed twice per week in both groups to evaluate serum progesterone (P(4)), while monthly samples were intended for insulin (INS) determination. Initial mean LW (16.7±1.0 kg) and BCS (3.31±0.12) were similar (p>0.05) in both groups. Mean serum insulin (1.37 vs. 1.18±0.09 ng/ml), age of puberty (215.7 vs. 226.5±6.6 days) and the percentage of goats reaching puberty (44.4 vs. 25.0±17.0%) did not differ (p>0.05) between BC and CONT group, respectively. However, increase in serum insulin during the second half of the experiment was observed in BC group (p<0.05) which was positively correlated with LW (r=0.95; p<0.05). In addition, as LW (r=-0.89) and serum insulin (r=-0.76) levels increased, the natural photoperiod decreased, revealing negative correlations (p<0.05) between the respective variables. In this study, BC supplementation did not promote precocious puberty and did not affect the percentage of goats reaching activation of the hypothalamic-hypophyseal-gonadal axis during the establishment of puberty. Nonetheless, BC supplementation positively affected the release pattern of insulin suggesting a potential role of BC as pancreas-activating molecule.
Corrias, Maria Valeria; Levreri, Isabella; Scaruffi, Paola; Raffaghello, Lizzia; Carlini, Barbara; Bocca, Paola; Prigione, Ignazia; Stigliani, Sara; Amoroso, Loredana; Ferrone, Soldano; Pistoia, Vito
2012-01-01
The high molecular weight melanoma-associated antigen (HMW-MAA) and the cytoplasmic melanoma-associated antigen (cyt-MAA/LGALS3BP) are expressed in melanoma. Their serum levels are increased in melanoma patients and correlate with clinical outcome. We investigated whether these molecules can serve as prognostic markers for neuroblastoma (NB) patients. Expression of cyt-MAA and HMW-MAA was evaluated by flow cytometry in NB cell lines, patients’ neuroblasts (FI-NB), and short-term cultures of these latter cells (cNB). LGALS3BP gene expression was evaluated by RT–qPCR on FI-NB, cNB, and primary tumor specimens. Soluble HMW-MAA and cyt-MAA were tested by ELISA. Cyt-MAA and HMW-MAA were expressed in NB cell lines, cNB, and FI-NB samples. LGALS3BP gene expression was higher in primary tumors and cNB than in FI-NB samples. Soluble cyt-MAA, but not HMW-MAA, was detected in NB cell lines and cNBs supernatants. NB patients’ serum levels of both antigens were higher than those of the healthy children. High cyt-MAA serum levels at diagnosis associated with higher incidence of relapse, independently from other known risk factors. In conclusion, both HMW-MAA and cyt-MAA antigens, and LGALS3BP gene, were expressed by NB cell lines and patients’ neuroblasts, and both antigens’ serum levels were increased in NB patients. Elevated serum levels of cyt-MAA at diagnosis correlated with relapse, supporting that cyt-MAA may serve as early serological biomarker to individuate patients at higher risk of relapse that may require a more careful follow-up, after being validated in a larger cohort of patients at different time-points during follow-up. Given its immunogenicity, cyt-MAA may also be a potential target for NB immunotherapy. PMID:21660451
de Jesus, Jemmyson Romário; Galazzi, Rodrigo Moretto; de Lima, Tatiani Brenelli; Banzato, Cláudio Eduardo Muller; de Almeida Lima E Silva, Luiz Fernando; de Rosalmeida Dantas, Clarissa; Gozzo, Fábio Cézar; Arruda, Marco Aurélio Zezzi
2017-12-01
An exploratory analysis using proteomic strategies in blood serum of patients with bipolar disorder (BD), and with other psychiatric conditions such as Schizophrenia (SCZ), can provide a better understanding of this disorder, as well as their discrimination based on their proteomic profile. The proteomic profile of blood serum samples obtained from patients with BD using lithium or other drugs (N=14), healthy controls, including non-family (HCNF; N=3) and family (HCF; N=9), patients with schizophrenia (SCZ; N=23), and patients using lithium for other psychiatric conditions (OD; N=4) were compared. Four methods for simplifying the serum samples proteome were evaluated for both removing the most abundant proteins and for enriching those of lower-abundance: protein depletion with acetonitrile (ACN), dithiothreitol (DTT), sequential depletion using DTT and ACN, and protein equalization using commercial ProteoMiner® kit (PM). For proteomic evaluation, 2-D DIGE and nanoLC-MS/MS analysis were employed. PM method was the best strategy for removing proteins of high abundance. Through 2-D DIGE gel image comparison, 37 protein spots were found differentially abundant (p<0.05, Student's t-test), which exhibited ≥2.0-fold change of the average value of normalized spot intensities in the serum of SCZ, BD and OD patients compared to subject controls (HCF and HCNF). From these spots detected, 13 different proteins were identified: ApoA1, ApoE, ApoC3, ApoA4, Samp, SerpinA1, TTR, IgK, Alb, VTN, TR, C4A and C4B. Proteomic analysis allowed the discrimination of patients with BD from patients with other mental disorders, such as SCZ. The findings in this exploratory study may also contribute for better understanding the pathophysiology of these disorders and finding potential serum biomarkers for these conditions. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Accurate Determination of Soluble Axl by Enzyme-Linked Immunosorbent Assay.
Dengler, Mirko; Huber, Heidemarie; Müller, Christian J; Zellmer, Angela; Rauch, Peter; Mikulits, Wolfgang
2016-11-01
Levels of soluble Axl (sAxl) are routinely assessed in human sera by sandwich enzyme-linked immunosorbent assay (ELISA). Although sAxl values are suggested to diagnose different types of disorders, no uniform ELISA method is available, allowing the reliable interassay comparison between results. Furthermore, little is known about the stability of sAxl under storage conditions, which is a relevant parameter for biomedical trials. The evaluation of sAxl stability under various stress conditions and the determination of proper conditions to use the sAxl ELISA for routine clinical applications are of great interest. In this study, serum samples were subjected to freeze-thaw cycles and incubation at different temperatures to analyze the stability of sAxl by ELISA. Dilution and spike-in experiments were carried out to examine the impact of serum and diluent components on the ELISA performance. Various diluents and media were employed to resolve masking effects of the serum. The assay components were further optimized for long-term usability by treatment with stabilizers and validation under temperature stress. Indeed, sAxl showed long-term stability in serum during freeze-thaw cycles and incubation under temperature stress conditions. The dilution experiments revealed that unknown components in the serum caused masking effects that can be reduced by proper dilutions. The assay performance was further increased by using a standardized buffer system to dilute serum samples. Stabilization of coated plates and of streptavidin-horseradish peroxidase allowed long-term storage for up to 6 months. In sum, our data demonstrate proper ELISA conditions, allowing the accurate analysis of sAxl levels in human serum.
Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing
2015-01-01
Objective Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Methods Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. Results A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. Conclusion A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC. PMID:26487969
Friedrich, Adrián; Ledesma, Martín; Landone, Ignacio; Ferrari, Alejandro; Leoni, Juliana
2014-09-01
A monoclonal antibody (mAb) was produced against immunoglobulin M (IgM) of South American camelids. A single radial immunodiffusion (SRID) assay and a competitive enzyme-linked immunosorbent assay (ELISA) were developed to measure IgM in serum samples. Isotype and specificity of the mAb were assessed. The performance of the SRID assay was preliminarily evaluated in terms of working range, plate stability over a 4-week period, and initial intra- and interassay variation. The concentration of IgM was determined in 55 samples by SRID assay and ELISA, and results were not significantly different by t-test (0.64 ± 0.19 mg/ml for the SRID assay, and 0.58 ± 0.24 mg/ml for ELISA; P = 0.1489). The mAb was shown to be stable over the 4-week evaluation period, and the SRID assay was reproducible when tested in triplicate for intra-assay variability and in quadruplicate for interassay variability, with a percentage coefficient of variation of less than or equal to 5%. Also, the SRID assay proved to be sensitive enough to measure IgM levels in undiluted serum samples, and had a good correlation with ELISA. The current study is intended to submit a preliminary report of a mAb against IgM of South American camelids, and suggest the future potential of the mAb developed for diagnostic application, including use in the SRID assay. © 2014 The Author(s).
Maternal serum bisphenol A levels and risk of pre-eclampsia: a nested case-control study.
Ye, Yunzhen; Zhou, Qiongjie; Feng, Liping; Wu, Jiangnan; Xiong, Yu; Li, Xiaotian
2017-12-01
Although recent studies have indicated the potential adverse effects of maternal bisphenol A (BPA) exposure on pregnancy such as increasing the risk of pre-eclampsia, epidemiological evidence is limited. We aimed to evaluate the relationship between maternal BPA exposure and the risk of pre-eclampsia. We conducted a nested case-control study among 173 women (74 cases of pre-eclampsia and 99 controls). BPA concentrations were measured using liquid chromatography-mass spectrometry in the maternal serum samples collected during 16-20 gestational weeks. Multivariate logistic models were used to examine the relationship between maternal serum BPA concentrations and the risk of pre-eclampsia. BPA was detectable (>0.1 µg/l) in 78.6% of the maternal serum samples at three levels: low (<2.24 µg/l), medium (2.24-4.44 µg/l), and high (>4.44 µg/l). BPA concentrations were significantly higher in the serum samples collected from the pre-eclampsia cases than those from controls (median: 3.40 vs. 1.50 µg/l, P < 0.01). With adjustment for maternal age, primiparous and BMI, the odds of developing pre-eclampsia were significantly elevated in subjects with high serum BPA levels compared with those with low levels (adjusted OR = 16.46, 95%CI = 5.42-49.85) regardless of subcategories of pre-eclampsia including severity and onset time. Among the pre-eclampsia subjects, the maternal serum concentration of BPA was not different between the early- and late-onset subjects (median: 3.09 vs. 3.50 µg/l, P = 0.57), but surprisingly higher in mild pre-eclampsia subjects compared with severe pre-eclampsia subjects (median: 5.20 vs. 1.80 µg/l, P < 0.01). These results demonstrated that maternal exposure to high level of BPA could be associated with an increased risk of pre-eclampsia. © The Author 2017. Published by Oxford University Press on behalf of the European Public Health Association.
Maternal serum bisphenol A levels and risk of pre-eclampsia: a nested case–control study
Ye, Yunzhen; Zhou, Qiongjie; Feng, Liping; Wu, Jiangnan; Xiong, Yu; Li, Xiaotian
2017-01-01
Abstract Background Although recent studies have indicated the potential adverse effects of maternal bisphenol A (BPA) exposure on pregnancy such as increasing the risk of pre-eclampsia, epidemiological evidence is limited. We aimed to evaluate the relationship between maternal BPA exposure and the risk of pre-eclampsia. Methods We conducted a nested case–control study among 173 women (74 cases of pre-eclampsia and 99 controls). BPA concentrations were measured using liquid chromatography-mass spectrometry in the maternal serum samples collected during 16–20 gestational weeks. Multivariate logistic models were used to examine the relationship between maternal serum BPA concentrations and the risk of pre-eclampsia. Results BPA was detectable (>0.1 µg/l) in 78.6% of the maternal serum samples at three levels: low (<2.24 µg/l), medium (2.24-4.44 µg/l), and high (>4.44 µg/l). BPA concentrations were significantly higher in the serum samples collected from the pre-eclampsia cases than those from controls (median: 3.40 vs. 1.50 µg/l, P < 0.01). With adjustment for maternal age, primiparous and BMI, the odds of developing pre-eclampsia were significantly elevated in subjects with high serum BPA levels compared with those with low levels (adjusted OR = 16.46, 95%CI = 5.42–49.85) regardless of subcategories of pre-eclampsia including severity and onset time. Among the pre-eclampsia subjects, the maternal serum concentration of BPA was not different between the early- and late-onset subjects (median: 3.09 vs. 3.50 µg/l, P = 0.57), but surprisingly higher in mild pre-eclampsia subjects compared with severe pre-eclampsia subjects (median: 5.20 vs. 1.80 µg/l, P < 0.01). Conclusions These results demonstrated that maternal exposure to high level of BPA could be associated with an increased risk of pre-eclampsia. PMID:29186464
Huang, Jing-Tao; Yang, Ying; Hu, Yi-Min; Liu, Xing-Hui; Liao, Mei-Yan; Morgan, Roy; Yuan, Er-Feng; Li, Xia; Liu, Song-Mei
2018-05-01
Despite implications of persistence of hepatitis B virus (HBV) covalently closed circular DNA (cccDNA) in the development of hepatocellular carcinoma (HCC), little is known about serum cccDNA in HBV-infected diseases. We developed a cccDNA-selective droplet digital PCR (ddPCR) to assess cccDNA content and dynamics across different stages of HCC development. One hundred forty-seven serum samples and 35 formalin-fixed, paraffin-embedded tumor tissues were derived from patients with HCC or HBV hepatitis/cirrhosis. After specific amplification and selective digestion, probe-based ddPCR was used to quantify cccDNA copy numbers in single cells and clinical samples. The cccDNA in single HepG2.2.15 cells ranged from 0 to 10.8 copies/cell. Compared with non-HCC patients, HCC patients showed a higher cccDNA-positive rate (89.9% versus 53.2%; P = 4.22 × 10 -6 ) and increased serum cccDNA contents (P = 0.002 and P = 0.041 for hepatitis and cirrhosis patients, respectively). Serum cccDNA ranged from 84 to 1.07 × 10 5 copies/mL. Quantification of serum cccDNA and HBV-DNA was an effective way to discriminate HCC patients from non-HCC patients, with areas under the curve of receiver operating characteristic of 0.847 (95% CI, 0.759-0.935; sensitivity, 74.5%; specificity, 93.7%). cccDNA-selective ddPCR is sensitive to detect cccDNA in single cells and different clinical samples. Combined analysis of serum cccDNA and HBV-DNA may be a promising strategy for HBV-induced HCC surveillance and antiviral therapy evaluation. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M
2016-09-01
We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.
Afridi, Hassan Imran; Kazi, Tasneem Gul; Kazi, Naveed; Kandhro, Ghulam Abbas; Baig, Jameel Ahmed; Shah, Abdul Qadir; Khan, Sumaira; Kolachi, Nida Fatima; Wadhwa, Sham Kumar; Shah, Faheem
2011-01-01
The most common cause of blindness in developing countries is vitamin A deficiency. The World Health Organization (WHO) estimates 13.8 million children have some degree of visual loss related to vitamin A deficiency. The causes of night blindness in children are multifactorial and particular consideration has been given to childhood nutritional deficiency, which is the most common problem found in underdeveloped countries. Such deficiency can result in physiological and pathological processes that in turn influence biological sample composition. Vitamin and mineral deficiency prevents more than two billion people from achieving their full intellectual and physical potential. This study was designed to compare the levels of magnesium (Mg), calcium (Ca), potassium (K), and sodium (Na) in scalp hair, serum, blood, and urine of night blindness children in two age groups, (1-5) and (6-10) years, of both genders comparing them to sex- and age-matched controls. A microwave assisted wet acid digestion procedure was developed as a sample pretreatment for the determination of Mg, Ca, K, and Na in biological samples of children with night blindness. The proposed method was validated by using conventional wet digestion and certified reference samples of hair, serum, blood, and urine. The digests of all biological samples were analysed for Mg, Ca, K, and Na by flame atomic absorption spectrometry (FAAS) using an air/acetylene flame. The results indicated significantly lower levels of Mg, Ca, and K in the biological samples (blood, serum, and scalp hair) of male and female children with night blindness and higher values of Na compared with control subjects of both genders. These data present guidance to clinicians and other professionals investigating deficiency of essential mineral elements in biological samples (scalp hair, serum, and blood) of children with night blindness.
Ghafourian, Mehri; Esmaeili, Mehrnosh; Dashti-Gerdabi, Nader; Sadeghi, Alireza; Malekei Naseri, Ali; Kazemi, Akhtar
2017-01-01
Thalassemia syndrome is the most common genetic disorder in the world and infection is the second cause of death in these patients. Measurement of serum C3 and C4 complement factors in serum was done in 60 patients with beta thalassemia major in comparison with 30 healthy subjects as control group. The serum level of C3 and C4 complement factors in 60 patients with beta thalassemia major who were randomly selected from among the patients referred to Shafa Hospital of Ahvaz was evaluated and compared with 30 samples from healthy individuals with no history of recent infectious or autoimmune diseases. It should be noted that single-radial-immunodiffusion assay was used in this study. This study has shown a significant reduction in serum levels of C3 and C4 in patients compared to controls (P value < 0.05). Decreased synthesis or increased consumption of complement factors in patients receiving multiple blood transfusions might lead to continuous contact between the immune system and various antigens, causing nonstop use of complement factors, recurrent infections, changes in parameters of the immune system due to iron overload as well as exposure to infectious factors such as HBV, HCV, HIV, and HTLV through blood transfusion.
A prospective evaluation of serum kynurenine metabolites and risk of pancreatic cancer.
Huang, Joyce Y; Butler, Lesley M; Midttun, Øivind; Ulvik, Arve; Wang, Renwei; Jin, Aizhen; Gao, Yu-Tang; Ueland, Per M; Koh, Woon-Puay; Yuan, Jian-Min
2018-01-01
Serum pyridoxal 5'-phosphate (PLP), the active form of vitamin B6, is associated with reduced risk of pancreatic cancer. Data on functional measures of vitamin B6 status and risk of pancreatic cancer is lacking. A nested case-control study involving 187 incident cases of pancreatic cancer and 362 individually matched controls were conducted within two prospective cohorts to evaluate the associations between kynurenine metabolites in pre-diagnostic serum samples and risk of pancreatic cancer. Higher serum concentrations of 3-hydroxyanthranilic acid (HAA) and the HAA:3-hydroxykynurenine (HK) ratio (a measure for in vivo functional status of PLP) were significantly associated with reduced risk of pancreatic cancer. Compared with the lowest tertile, odds ratios (95% confidence intervals) of pancreatic cancer for the highest tertile was 0.62 (0.39, 1.01) for HAA, and 0.59 (0.35-0.98) for the HAA:HK ratio, after adjustment for potential confounders and serum PLP (both Ps for trend<0.05). The kynurenine:tryptophan ratio or neopterin was not significantly associated with pancreatic cancer risk. The inverse association between HAA or the HAA:HK ratio and risk of pancreatic cancer supports the notion that functional status of PLP may be a more important measure than circulating PLP alone for the development of pancreatic cancer.
Wiener, Carolina David; de Mello Ferreira, Sharon; Pedrotti Moreira, Fernanda; Bittencourt, Guilherme; de Oliveira, Jacqueline Flores; Lopez Molina, Mariane; Jansen, Karen; de Mattos Souza, Luciano Dias; Rizzato Lara, Diogo; Portela, Luiz Valmor; da Silva, Ricardo Azevedo; Oses, Jean Pierre
2015-09-15
Nerve growth factor (NGF) is an important member of the neurotrophins group and their involvement in the pathophysiology of major depression disorder (MDD) and suicide risk (SR) has been recently suggested. The aim of this study is to evaluate the changes in NGF serum levels in individuals with MDD and with or without risk of suicide, in subjects from a young population-based sample. This is a paired cross-sectional study nested in a population-based study. Individuals were rated for MDD and SR by a diagnostic interview--Mini International Neuropsychiatric Interview (M.I.N.I). The total population of the sample was comprised of 141 subjects distributed in three groups: 47 healthy controls, 47 subjects with current depressive episode without SR (MDD) and 47 subjects with current depressive episode and with SR (MDD + SR). NGF serum levels were significantly reduced in the MDD and MDD + SR groups when compared with controls (p ≤ 0.001). However, there were no differences in NGF levels between the MDD and MDD + SR groups (p = 1.000). These results suggest that reduced NGF serum levels can be a possible biomarker of MDD. Copyright © 2015 Elsevier B.V. All rights reserved.
Detection of hepatitis E virus RNA in saliva for diagnosis of acute infection.
Rivero-Juarez, A; Frias, M; Lopez-Lopez, P; Martinez-Peinado, A; Risalde, M Á; Brieva, T; Machuca, I; Camacho, Á; García-Bocanegra, I; Gomez-Villamandos, J C; Rivero, A
2018-04-16
Diagnosis of acute hepatitis E virus (HEV) infection is established by detection of anti-HEV IgM antibodies by ELISA or by amplification of serum viral RNA. Here, we evaluate the diagnostic value of testing HEV RNA in saliva to identify patients with acute HEV infection. Prospective proof-of-concept study including patients with acute hepatitis. Whole blood and neat saliva samples were obtained from all patients. Saliva samples were processed and analysed for HEV RNA by RT-PCR within 2 hr after collection. A total of 34 patients with acute hepatitis and 12 healthy donors were included in the study. HEV RNA in serum was confirmed by RT-PCR in eight of these patients (23.5%; 95% CI: 12.2%-40.2%). HEV was isolated in the saliva of eight of 34 patients (23.5%; 95% CI: 12.2%-40.2%). All patients with HEV RNA amplified in saliva had detectable HEV RNA in serum. HEV was isolated neither in the saliva of any of the 26 patients without detectable HEV RNA in serum nor in healthy donors. Our study suggests that acute HEV infection could be diagnosed by assessing viral load in saliva. © 2018 Blackwell Verlag GmbH.
2013-01-01
Background Toxoplasmosis is one of the most common food borne zoonoses worldwide, and can be a serious life-threatening disease in the congenitally infected fetus and in immunosupressed patients. Among food animals, sheep along with goats and pigs possess the highest incidence of T. gondii cysts in meat, and play a major role as a source of human infection. Methods In this study, a new commercial ELISA kit (PrioCHECK® Toxoplasma Ab SR, Prionics Schlieren-Zurich, Switzerland) for the detection of anti-T. gondii antibodies in serum, plasma and meat juice of sheep, was evaluated by comparing it with the indirect fluorescent antibody test (IFAT), indirect haemagglutination test (IHA) and real-time PCR, on samples from experimentally inoculated and naturally exposed sheep. Results The commercial ELISA detected the infection status in 50% and 100% of sheep orally inoculated with 10,000 T. gondii oocysts (n = 6), from two or three weeks post infection (wpi), respectively, both on serum and plasma samples. Meat juice from all experimentally inoculated sheep collected at slaughter (12 wpi) showed positive ELISA values. In naturally exposed sheep (n = 396), the ELISA showed a very good agreement with IFAT (kappa = 0.91-1.0) and IHA (kappa = 0.96-1.0) performed on serum; and a positive correlation was observed between ELISA values and IFAT titers. By a Receiver Operating Characteristics (ROC) curve analysis, the commercial ELISA had relative sensitivities between 93.33% and 100%, and relative specificities between 96.87% and 100% respect to IFAT and IHA, depending on the considered cut-off value and animal groups tested. Furthermore, the ELISA correctly recognized all animals reacting positive in real-time PCR. The ELISA results on meat juice agreed with those on serum samples in all experimentally inoculated animals, and in 94 out of 96 (97.9%) naturally exposed sheep, when meat juice was tested at a 1:10 dilution. Conclusion The commercial ELISA kit evaluated in this study could represent a valuable tool to improve the surveillance and reporting system for T. gondii in sheep populations at the farm level or for diagnosis at the slaughterhouse, contributing to the control of this widespread zoonosis. PMID:23561035
A Common Variant in the SETD7 Gene Predicts Serum Lycopene Concentrations.
D'Adamo, Christopher R; D'Urso, Antonietta; Ryan, Kathleen A; Yerges-Armstrong, Laura M; Semba, Richard D; Steinle, Nanette I; Mitchell, Braxton D; Shuldiner, Alan R; McArdle, Patrick F
2016-02-06
Dietary intake and higher serum concentrations of lycopene have been associated with lower incidence of prostate cancer and other chronic diseases. Identifying determinants of serum lycopene concentrations may thus have important public health implications. Prior studies have suggested that serum lycopene concentrations are under partial genetic control. The goal of this research was to identify genetic predictors of serum lycopene concentrations using the genome-wide association study (GWAS) approach among a sample of 441 Old Order Amish adults that consumed a controlled diet. Linear regression models were utilized to evaluate associations between genetic variants and serum concentrations of lycopene. Variant rs7680948 on chromosome 4, located in the intron region of the SETD7 gene, was significantly associated with serum lycopene concentrations (p = 3.41 × 10(-9)). Our findings also provided nominal support for the association previously noted between SCARB1 and serum lycopene concentrations, although with a different SNP (rs11057841) in the region. This study identified a novel locus associated with serum lycopene concentrations and our results raise a number of intriguing possibilities regarding the nature of the relationship between SETD7 and lycopene, both of which have been independently associated with prostate cancer. Further investigation into this relationship might help provide greater mechanistic understanding of these associations.
A Common Variant in the SETD7 Gene Predicts Serum Lycopene Concentrations
D’Adamo, Christopher R.; D’Urso, Antonietta; Ryan, Kathleen A.; Yerges-Armstrong, Laura M.; Semba, Richard D.; Steinle, Nanette I.; Mitchell, Braxton D.; Shuldiner, Alan R.; McArdle, Patrick F.
2016-01-01
Dietary intake and higher serum concentrations of lycopene have been associated with lower incidence of prostate cancer and other chronic diseases. Identifying determinants of serum lycopene concentrations may thus have important public health implications. Prior studies have suggested that serum lycopene concentrations are under partial genetic control. The goal of this research was to identify genetic predictors of serum lycopene concentrations using the genome-wide association study (GWAS) approach among a sample of 441 Old Order Amish adults that consumed a controlled diet. Linear regression models were utilized to evaluate associations between genetic variants and serum concentrations of lycopene. Variant rs7680948 on chromosome 4, located in the intron region of the SETD7 gene, was significantly associated with serum lycopene concentrations (p = 3.41 × 10−9). Our findings also provided nominal support for the association previously noted between SCARB1 and serum lycopene concentrations, although with a different SNP (rs11057841) in the region. This study identified a novel locus associated with serum lycopene concentrations and our results raise a number of intriguing possibilities regarding the nature of the relationship between SETD7 and lycopene, both of which have been independently associated with prostate cancer. Further investigation into this relationship might help provide greater mechanistic understanding of these associations. PMID:26861389
Scarano, S; Scuffi, C; Mascini, M; Minunni, M
2011-11-30
Only few papers deal with Surface Plasmon Resonance imaging (SPRi) direct detection on complex matrices, limiting the biosensor application to real analytical problems. In this work a SPRi biosensor for anti-bovine IgG detection in untreated human bodily fluids, i.e. diluted human serum and milk, was developed. Enhanced levels of cow's milk antibodies in children's serum are suspected for their possible correlation with Type 1 diabetes during childhood and their detection in real samples was up to now performed by classical immunoassays based on indirect detection. The biosensor was optimised in standard samples and then in untreated human milk for anti-bovine IgG direct detection. The key novelty of the work is the evaluation of matrix effect by applying to real samples an experimental and ex ante method previously developed for SPRi signal sampling in standard solutions, called "Data Analyzer"; it punctually visualises and analyses the behaviour of receptor spots of the array, to select only spot areas with the best specific vs. unspecific signal values. In this way, benefits provide by SPRi image analysis are exploited here to quantify and minimise drawbacks due to the matrix effect, allowing to by-pass every matrix pre-treatment except dilution. Copyright © 2011 Elsevier B.V. All rights reserved.
Neuroprotective effect of sevoflurane in general anaesthesia.
Ramos Ramos, Victoria; Mesa Suárez, Pablo; Santotoribio, José Diego; González García, María Ángela; Muñoz Hoyos, Antonio
2017-02-23
The aim of this study was to evaluate the brain damage caused by inhaled sevoflurane, by determining the concentration of serum S100B protein before and after the exposure to this drug as the only anaesthetic agent. Paediatric patients undergoing general anaesthesia for the conduct of a nuclear magnetic resonance were included in the study. A venous blood sample was taken from each patient before (basal sample) and after (post-exposure sample) administering the general anaesthesia. The concentration of serum S100B protein was determined in the basal (S100Bb) and post-exposure sample (S100Bp). A total of 72 patients were included in the study, with a mean patient age of 2 to 13 years (median=6), 28 males and 44 females. S100Bp values (median=66.5ng/L) were significantly lower (P=.0059) than those of S100Bb (median=84.0ng/L). The median of the difference between S100Bp and S100Bb was -11.0ng/L. Inhaled sevoflurane at low doses causes a decrease of serum S100B protein levels, hence, this drug could have a neuroprotective effect in the central nervous system. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Greibe, Eva; Nexo, Ebba
2011-11-01
Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. Intra-assay imprecision and linearity of the EIA kit was examined, employing serum pools of increasing holoTC concentrations. For the CobaSorb test, holoTC was measured before and after loading with 3-times 9 μg of vitamin B12 employing both the in-house ELISA and the EIA kit (n=25). The EIA kit showed an intra-assay CV between 2.2% and 5.8% for holoTC values ranging from 21 to 80 pmol/L. Employing diluted serum samples resulted in spurious high values of holoTC. The EIA kit performed well in relation to the CobaSorb test and classified the patients studied as capable of absorbing vitamin B12 (n=10) or not (n=15), as did the in-house ELISA. The Active B12 (holoTC) EIA kit proved suitable for use with the CobaSorb test, but not for analysis of diluted serum samples.
Specific IgA and IgG antibodies in paired serum and breast milk samples in human strongyloidiasis.
Mota-Ferreira, Daniela M L; Gonçalves-Pires, Maria do Rosário F; Júnior, Alvaro Ferreira; Sopelete, Mônica C; Abdallah, Vânia O S; Costa-Cruz, Julia M
2009-02-01
Strongyloidiasis, caused by the nematode Strongyloides stercoralis, is one of the major worldwide parasitic infections in humans. Breastfeeding may offer a potential protection against this infection. Feces, serum and milk samples were obtained from 90 lactating women from Clinical Hospital of Universidade Federal de Uberlândia, Brazil. The fecal samples were collected for parasitological diagnosis and the serum and milk samples were examined for specific S. stercoralis IgA and IgG antibodies using the indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assay (ELISA). Fecal examination showed that the rate of prevalence of S. stercoralis infection in the lactating women was 4.4%. IFAT manifested a 16.7% positivity rate for specific IgA antibody in serum and a 28.9% rate in milk samples; specific IgG was 41.1% in serum and 25.5% in milk samples. According to ELISA the positivity rate for specific IgA antibody was 21.1% in serum and 42.2% in milk samples; specific IgG was 40% in serum and 18.9% in milk samples. In serum samples, these immunological tests showed a concurrence of 91.1% and 94.4%, respectively, in detecting specific IgA and IgG antibodies. In milk samples, they showed a concurrence of 70% and 78.9%, respectively, in detecting specific IgA and IgG antibodies. There was a statistically significant difference between concordant and discordant results of immunological tests (P<0.0001). IFAT and ELISA highly concurred in their detection of specific S. stercoralis IgA and IgG antibodies in serum and in milk samples reconfirming prior studies that the serological method is a complement to the direct diagnosis of the parasite, and suggesting that immunological methods using milk samples can also be helpful. Furthermore, in endemic areas, infants may acquire antibodies to S. stercoralis from breast milk, possibly, contributing to the enhancement of specific mucosal immunity against this parasite.
Xie, Yan-Ming; Zhao, Yu-Bin; Jiang, Jun-Jie; Chang, Yan-Peng; Zhang, Wen; Shen, Hao; Lu, Peng-Fei
2013-09-01
Through consensus, establish a post-marketing scheme and the technical processes to evaluate Chinese medicine's immunotoxicity on a population, as well as its beneficial influences on the immune system. Provide regulations on the collection, storage and transportation of serum samples. This article applies to the post-marketing scientific evaluation of the immunotoxicity of parenterally administered, and for other ways of taking Chinese medicine.
López-Bascón, María Asunción; Calderón-Santiago, Mónica; Priego-Capote, Feliciano
2016-11-02
A novel class of endogenous mammalian lipids endowed with antidiabetic and anti-inflammatory properties has been recently discovered. These are fatty acid esters of hydroxy fatty acids (FAHFAs) formed by condensation between a hydroxy fatty acid and a fatty acid. FAHFAs are present in human serum and tissues at low nanomolar concentrations. Therefore, high sensitivity and selectivity profiling analysis of these compounds in clinical samples is demanded. An automated qualitative and quantitative method based on on-line coupling between solid phase extraction and liquid chromatography-tandem mass spectrometry has been here developed for determination of FAHFAs in serum with the required sensitivity and selectivity. Matrix effects were evaluated by preparation of calibration models in serum and methanol. Recovery factors ranged between 73.8 and 100% in serum. The within-day variability ranged from 7.1 to 13.8%, and the between-days variability varied from 9.3 to 21.6%, which are quite acceptable values taking into account the low concentration levels at which the target analytes are found. The method has been applied to a cohort of human serum samples to estimate the concentrations profiles as a function of the glycaemic state and obesity. Statistical analysis revealed three FAHFAs with levels significantly different depending on the glycaemic state or the body mass index. This automated method could be implemented in high-throughput analysis with minimum user assistance. Copyright © 2016 Elsevier B.V. All rights reserved.
Hillström, Anna; Bylin, Jonas; Hagman, Ragnvi; Björhall, Karin; Tvedten, Harold; Königsson, Kristian; Fall, Tove; Kjelgaard-Hansen, Mads
2016-10-28
In a dog with joint pain, it is important to determine whether it has suppurative joint disease, characterized by exudation of neutrophils in the synovial fluid, or not, as this affects choice of diagnostic tests and treatments. The aim of this study was to evaluate whether measurement of serum C-reactive protein (CRP) concentration could be used to discriminate between dogs with suppurative arthritis and osteoarthritis (OA). Furthermore, the concentrations of serum and synovial fluid interleukin (IL) 6 concentrations were measured in dogs with joint disease and in healthy dogs, and were correlated to serum CRP concentrations. Dogs with joint pain were enrolled prospectively and were classified to have suppurative arthritis or OA based on synovial fluid analysis and radiographic/arthroscopic findings. Healthy Beagles were enrolled as a comparative group. CRP and IL-6 concentrations were measured with canine-specific immunoassays. The performance of CRP concentration in discriminating between dogs with suppurative arthritis and OA was evaluated using a previously established clinical decision limit for CRP (20 mg/l), and by receiver operator characteristic (ROC) curve and logistic regression analysis. Comparisons of CRP and IL-6 concentrations between groups were performed using t-tests, and correlations by Spearman rank correlation coefficients. Samples were obtained from 31 dogs with suppurative arthritis, 34 dogs with OA, and 17 healthy dogs. Sixty-two out of 65 dogs with joint disease were correctly classified using the clinical decision limit for CRP. Evaluation of ROC curve and regression analysis indicated that serum CRP concentrations could discriminate between suppurative arthritis and OA. Dogs with suppurative arthritis had higher serum CRP and serum and synovial fluid IL-6 concentrations compared to dogs with OA (p < 0.001). Dogs with OA had higher synovial fluid IL-6 concentrations (p < 0.001), but not higher serum CRP (p = 0.29) or serum IL-6 (p = 0.07) concentrations, compared to healthy dogs. There was a positive correlation between synovial fluid IL-6 and serum CRP concentrations (r s = 0.733, p < 0.001), and between serum IL-6 and serum CRP concentrations (r s = 0.729, p < 0.001). CRP concentration was found to discriminate well between dogs with suppurative arthritis and OA.
Cashman, Kevin D; Kiely, Mairead; Kinsella, Michael; Durazo-Arvizu, Ramón A; Tian, Lu; Zhang, Yue; Lucey, Alice; Flynn, Albert; Gibney, Michael J; Vesper, Hubert W; Phinney, Karen W; Coates, Paul M; Picciano, Mary F; Sempos, Christopher T
2013-01-01
Background: The Vitamin D Standardization Program (VDSP) has developed protocols for standardizing procedures of 25-hydroxyvitamin D [25(OH)D] measurement in National Health/Nutrition Surveys to promote 25(OH)D measurements that are accurate and comparable over time, location, and laboratory procedure to improve public health practice. Objective: We applied VDSP protocols to existing ELISA-derived serum 25(OH)D data from the Irish National Adult Nutrition Survey (NANS) as a case-study survey and evaluated their effectiveness by comparison of the protocol-projected estimates with those from a reanalysis of survey serums by using liquid chromatography–tandem mass spectrometry (LC–tandem MS). Design: The VDSP reference system and protocols were applied to ELISA-based serum 25(OH)D data from the representative NANS sample (n = 1118). A reanalysis of 99 stored serums by using standardized LC–tandem MS and resulting regression equations yielded predicted standardized serum 25(OH)D values, which were then compared with LC–tandem MS reanalyzed values for all serums. Results: Year-round prevalence rates for serum 25(OH)D concentrations <30, <40, and <50 nmol/L were 6.5%, 21.9%, and 40.0%, respectively, via original ELISA measurements and 11.4%, 25.3%, and 43.7%, respectively, when VDSP protocols were applied. Differences in estimates at <30- and <40-nmol/L thresholds, but not at the <50-nmol/L threshold, were significant (P < 0.05). A reanalysis of all serums by using LC–tandem MS confirmed prevalence estimates as 11.2%, 27.2%, and 45.0%, respectively. Prevalences of serum 25(OH)D concentrations >125 nmol/L were 1.2%, 0.3%, and 0.6% by means of ELISA, VDSP protocols, and LC–tandem MS, respectively. Conclusion: VDSP protocols hold a major potential for national nutrition and health surveys in terms of the standardization of serum 25(OH)D data. PMID:23615829
Evaluation of the BT-1 serum assay for breast cancer.
Whitehurst, M M; Aldenderfer, P H; Sooy, M M; Strelkauskas, A J
1999-01-01
The BT-1 assay which identifies a novel breast tumor associated serum analyte was performed for 143 patients previously diagnosed with breast cancer. Mucin tumor markers CA15-3/CA27-29 values were available for 50 patients and there was very minor overlap between patients positive by both tests. Patients' follow-up clinical status at sample draw was compared to BT-1 assay results. 27% of patients originally diagnosed as Stage II and 20% patients originally diagnosed as Stage III who were evaluated 'no disease' had positive BT-1 values. 8% patients diagnosed as Stage II had negative BT-1 results in samples drawn within 90 days of chemotherapy initiation, whereas 23% of patients diagnosed as Stage III cancer were BT-1 test positive within 90 days of chemotherapy initiation. 50% of patients tested before initial breast cancer surgery had positive BT-1 values, suggesting that the BT-1 assay may be useful in identification women with more advanced disease at diagnosis.
Lower, K S; Medleau, L M; Hnilica, K; Bigler, B
2001-12-01
Canine scabies is a challenging disease to diagnose because sarcoptic mites are hard to find on skin scrapings. The purpose of this study was to evaluate a serologic enzyme-linked immunosorbent assay (ELISA) as an aid in the diagnosis of canine scabies. In addition, serum samples were obtained post treatment to determine the duration and persistence of circulating scabies antibodies after resolution of natural infection. Nineteen dogs diagnosed with sarcoptic mange and 38 control dogs were tested. Sixteen scabies-infested dogs showed positive pretreatment ELISA results (84.2% sensitivity). Thirty-four control dogs showed negative ELISA results (89.5% specificity). In the 11 scabies dogs from which multiple post treatment serum samples were obtained, detectable antibodies were not present 1 month after treatment in four cases, but were present for 1-4.5 months post treatment in seven dogs. Our results suggest that this scabies ELISA test is useful in the diagnosis of canine scabies.
A single, continuous metric to define tiered serum neutralization potency against HIV
Hraber, Peter Thomas; Korber, Bette Tina Marie; Wagh, Kshitij; ...
2018-01-19
HIV-1 Envelope (Env) variants are grouped into tiers by their neutralization-sensitivity phenotype. This helped to recognize that tier 1 neutralization responses can be elicited readily, but do not protect against new infections. Tier 3 viruses are the least sensitive to neutralization. Because most circulating viruses are tier 2, vaccines that elicit neutralization responses against them are needed. While tier classification is widely used for viruses, a way to rate serum or antibody neutralization responses in comparable terms is needed. Logistic regression of neutralization outcomes summarizes serum or antibody potency on a continuous, tier-like scale. It also tests significance of themore » neutralization score, to indicate cases where serum response does not depend on virus tiers. The method can standardize results from different virus panels, and could lead to high-throughput assays, which evaluate a single serum dilution, rather than a dilution series, for more efficient use of limited resources to screen samples from vaccinees.« less
A single, continuous metric to define tiered serum neutralization potency against HIV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hraber, Peter Thomas; Korber, Bette Tina Marie; Wagh, Kshitij
HIV-1 Envelope (Env) variants are grouped into tiers by their neutralization-sensitivity phenotype. This helped to recognize that tier 1 neutralization responses can be elicited readily, but do not protect against new infections. Tier 3 viruses are the least sensitive to neutralization. Because most circulating viruses are tier 2, vaccines that elicit neutralization responses against them are needed. While tier classification is widely used for viruses, a way to rate serum or antibody neutralization responses in comparable terms is needed. Logistic regression of neutralization outcomes summarizes serum or antibody potency on a continuous, tier-like scale. It also tests significance of themore » neutralization score, to indicate cases where serum response does not depend on virus tiers. The method can standardize results from different virus panels, and could lead to high-throughput assays, which evaluate a single serum dilution, rather than a dilution series, for more efficient use of limited resources to screen samples from vaccinees.« less
Zhang, Zhigang; Liu, Guowen; Li, Xiaobing; Gao, Li; Guo, Changming; Wang, Hongbin; Wang, Zhe
2010-12-01
Ketosis in dairy cows can lead to poor reproductive success and decreased milk production. Since the serum concentrations of copper (Cu) and zinc (Zn) are closely associated with the health status of cows, we investigated whether serum concentrations of Cu and Zn differed in dairy cows with subclinical ketosis and healthy dairy cows. Blood samples of 19 healthy dairy cows and 15 subclinically ketotic dairy cows were collected from three farms, and the concentrations of β-hydroxybutyrate (BHBA), glucose, non-esterified fatty acids (NEFA), Cu, and Zn were determined. Subclinically ketotic dairy cows had significantly higher BHBA and NEFA levels (p < 0.01) and lower glucose (p < 0.01) than healthy dairy cows. Likewise, serum concentrations of Zn were significantly decreased (p < 0.05) in dairy cows with subclinical ketosis. There was no significant difference observed for serum Cu concentration between healthy and subclinically ketotic dairy cows. This study suggests that a decreased serum Zn concentration could be a cause of decreased reproductive performance in subclinically ketotic dairy cows.
Paz, Gustavo F; Rugani, Jeronimo M N; Marcelino, Andreza P; Gontijo, Célia M F
2018-06-01
The aim of this study was to evaluate the relationship between naturally occurring Leishmania spp. infections in dogs (Canis familiaris) and the practical implications of the use of serological and molecular methods to confirm diagnoses. The study population consisted of 96 domestic dogs in southeastern Brazil. Serum samples were tested for the presence of anti-Leishmania immunoglobulin G (IgG) antibodies using four commercial canine visceral leishmaniasis kits. Dogs confirmed positive by immunofluorescence antibody test (IFAT) were culled and samples from mesenteric lymph nodes, spleen border, bone marrow and ear skin were taken and submitted to DNA extraction. PCR reactions were performed using primers that amplify a 300-350 bp fragment of the Leishmania ribosomal internal transcribed spacer 1 (ITS1) region. The ITS1 amplified products were analyzed by PCR-RFLP using Hae III restriction endonuclease. To confirm the Leishmania species detected by PCR, each purified sample was sequenced in duplicate. Of the 96 serum samples submitted to serological assays, 8 (8.3%) tested positive for Leishmania by IFAT, 4 (4.1%) by ELISA, 2 (2.1%) by rK39 RDT and 7 (7.3%) by DPP. Four of these infected dogs (50%) were found to be infected only by Leishmania braziliensis or Leishmania amazonensis, and their serum samples tested positive by IFAT and DPP. These findings demonstrate for the first time that cross-reactivity of L. braziliensis and L. amazonensis infection in dogs can be found using the DPP serum test. This is the first record of Leishmania (Leishmania) amazonensis confirmed by a specific molecular marker in dogs (Canis familiaris) from Belo Horizonte, Brazil. Copyright © 2018 Elsevier B.V. All rights reserved.
Wollanke, B; Gerhards, H; Brem, S; Kopp, H; Meyer, P
1998-04-01
Between February 1993 and July 1997, 150 horses suffering from recurrent uveitis were subjected to parsplana vitrectomy. In these horses, antibody titers to Leptospira serovars were determined in serum samples and in samples from diluted vitreous collected during vitrectomy. Although the vitreous samples were diluted with 250 ml of balanced salt solution, in 86 of the 150 vitreous samples (= 57%) the antibody titers were higher than in the serum samples. Additionally, serum samples from 77 horses suffering from ERU, but which were not subjected to vitrectomy, and serum samples from 97 horses with clinically normal eyes were analyzed for antibodies to Leptospira serovars. Among the 227 horses with ERU (150 treated surgically, 77 treated conservatively) 50 horses (50 of 227 = 22%) had serum antibody titers to Leptospira serovars of > or = 1:800. Among the 97 horses with clinically normal eyes, 24 horses (24 of 97 = 25%) had serum antibody titers to Leptospira serovars of > or = 1:800. In undiluted vitreous samples from 20 horses with clinically normal eyes, no antibody titers to Leptospira serovars could be detected. Among the 150 horses with ERU, 90 animals (90 of 150 = 60%) had antibody titers of > or = 1:100 in the diluted vitreous samples, the difference being highly significant (p < 0.001). The findings are discussed in relation to the etiology of recurrent uveitis in horses.
Immunodiagnosis of toxocarosis in humans: evaluation of a new enzyme-linked immunosorbent assay kit.
Jacquier, P; Gottstein, B; Stingelin, Y; Eckert, J
1991-01-01
Excretory/secretory (E/S) antigen derived from second-stage larvae of Toxocara canis maintained in defined medium in vitro has been well established worldwide for the immunodiagnosis of human toxocarosis by enzyme-linked immunosorbent assay. Such an enzyme-linked immunosorbent assay, based on the detection of human anti-T. canis (E/S antigen) serum immunoglobulin G, has recently been commercialized by Biokema-Affinity Products (Crissier-Lausanne, Switzerland). This commercial test kit was evaluated with regard to its application in a routine diagnostic laboratory and the reliability of the results. Of 78 patients with suspected clinical toxocarosis, 71 had anti-T. canis antibodies (positive serological result) corresponding to a diagnostic sensitivity of 91%; 14% of serum samples (n = 199) from patients with protozoan or with helminthic infections also showed positive reactions mainly related to infections with Trichinella, Strongyloides, and Fasciola species. An epidemiological study with 1,000 serum samples from randomly selected healthy blood donors and children in Switzerland demonstrated a seroprevalence of 2.7%. The test kit under evaluation had an overall diagnostic sensitivity of 91% and a relative specificity of 86%, the latter being related to some protozoan and helminthic infections. Because of the scarcity of such infections, potential cross-reactivity does not play a major role under the conditions found in the middle part of Europe. In conclusion, the application of the test kit provided for use in this study can be recommended for routine diagnostic use. PMID:1774303
Jafari, M T; Rezaei, B; Zaker, B
2009-05-01
Application of ion mobility spectrometry (IMS) as the detection technique for a separation method based on molecular imprinted polymer (MIP) was investigated and evaluated for the first time. On the basis of the results obtained in this work, the MIP-IMS system can be used as a powerful technique for separation, preconcentration, and detection of the metronidazole drug in pharmaceutical and human serum samples. The method is exhaustively validated in terms of sensitivity, selectivity, recovery, reproducibility, and column capacity. The linear dynamic range of 0.05-70.00 microg/mL was obtained for the determination of metronidazole with IMS. The recovery of analyzed drug was calculated to be above 89%, and the relative standard deviation (RSD) was lower than 6% for all experiments. Various real samples were analyzed with the coupled techniques, and the results obtained revealed the efficient cleanup of the samples using MIP separation before the analysis by IMS as a detection technique.
Dusek, Robert J.; Hall, Jeffrey S.; Nashold, Sean W.; Teslaa, Joshua L.; Ip, Hon S.
2011-01-01
The utility of using Nobuto paper strips for the detection of avian influenza antibodies was examined in mallards (Anas platyrhynchos) experimentally infected with low pathogenic avian influenza viruses. Blood was collected 2 wk after infection and was preserved either as serum or whole blood absorbed onto Nobuto strips. Analysis of samples using a commercially available blocking enzyme-linked immunosorbent assay revealed comparable results (???96% sensitivity for all methods) between sera stored at -30 C and the Nobuto strip preservation method even when the Nobuto strips were stored up to 3 mo at room temperature (RT). Significant differences were detected in the ratio of sample absorbance to negative control absorbance for Nobuto strips stored at RT compared with sera stored at -30 C, although these differences did not affect the ability of the test to reliably detect positive and negative samples. Nobuto strips are a convenient and sensitive alternative to the collection of serum samples when maintaining appropriate storage temperatures is difficult. ?? 2011 American Association of Avian Pathologists.
Espejo, L A; Zagmutt, F J; Groenendaal, H; Muñoz-Zanzi, C; Wells, S J
2015-11-01
The objective of this study was to evaluate the performance of bacterial culture of feces and serum ELISA to correctly identify cows with Mycobacterium avium ssp. paratuberculosis (MAP) at heavy, light, and non-fecal-shedding levels. A total of 29,785 parallel test results from bacterial culture of feces and serum ELISA were collected from 17 dairy herds in Minnesota, Pennsylvania, and Colorado. Samples were obtained from adult cows from dairy herds enrolled for up to 10 yr in the National Johne's Disease Demonstration Herd Project. A Bayesian latent class model was fitted to estimate the probabilities that bacterial culture of feces (using 72-h sedimentation or 30-min centrifugation methods) and serum ELISA results correctly identified cows as high positive, low positive, or negative given that cows were heavy, light, and non-shedders, respectively. The model assumed that no gold standard test was available and conditional independency existed between diagnostic tests. The estimated conditional probabilities that bacterial culture of feces correctly identified heavy shedders, light shedders, and non-shedders were 70.9, 32.0, and 98.5%, respectively. The same values for the serum ELISA were 60.6, 18.7, and 99.5%, respectively. Differences in diagnostic test performance were observed among states. These results improve the interpretation of results from bacterial culture of feces and serum ELISA for detection of MAP and MAP antibody (respectively), which can support on-farm infection control decisions and can be used to evaluate disease-testing strategies, taking into account the accuracy of these tests. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Antonucci, FrancescoPaolo; Cento, Valeria; Sorbo, Maria Chiara; Manuelli, Matteo Ciancio; Lenci, Ilaria; Sforza, Daniele; Di Carlo, Domenico; Milana, Martina; Manzia, Tommaso Maria; Angelico, Mario; Tisone, Giuseppe; Perno, Carlo Federico; Ceccherini-Silberstein, Francesca
2017-08-01
We evaluated the performance of a rapid method to quantify HCV-RNA in the hepatic and extrahepatic compartments, by using for the first time the Abbott RealTime HCV-assay. Non-tumoral (NT), tumoral (TT) liver samples, lymph nodes and ascitic fluid from patients undergoing orthotopic-liver-transplantation (N=18) or liver resection (N=4) were used for the HCV-RNA quantification; 5/22 patients were tested after or during direct acting antivirals (DAA) treatment. Total RNA and DNA quantification from tissue-biopsies allowed normalization of HCV-RNA concentrations in IU/μg of total RNA and IU/10 6 liver-cells, respectively. HCV-RNA was successfully quantified with high reliability in liver biopsies, lymph nodes and ascitic fluid samples. Among the 17 untreated patients, a positive and significant HCV-RNA correlation between serum and NT liver-samples was observed (Pearson: rho=0.544, p=0.024). Three DAA-treated patients were HCV-RNA "undetectable" in serum, but still "detectable" in all tested liver-tissues. Differently, only one DAA-treated patient, tested after sustained-virological-response, showed HCV-RNA "undetectability" in liver-tissue. HCV-RNA was successfully quantified with high reliability in liver bioptic samples and extrahepatic compartments, even when HCV-RNA was "undetectable" in serum. Abbott RealTime HCV-assay is a good diagnostic tool for HCV quantification in intra- and extra-hepatic compartments, whenever a bioptic sample is available. Copyright © 2017 Elsevier B.V. All rights reserved.
Dong, Dong; Zhang, Lufang; Jia, Li; Ji, Wei; Wang, Zhiyong; Ren, Li; Niu, Ruifang; Zhou, Yunli
2018-06-01
Periostin (POSTN) plays an important role in numerous cancers, especially in gastrointestinal malignancy. The objective of this study was to investigate the diagnostic and prognostic role of serum POSTN in colorectal cancer (CRC). Serum periostin, together with CEA, CA19.9, CA72.4, and CA242 levels were measured in samples from 108 patients with CRC and 56 healthy controls, and their correlation with clinical characteristics was further analyzed. Receiver operating curves (ROC), Kaplan-Meier curves, and log-rank analyses were used to evaluate diagnostic and prognostic significance. Serum POSTN levels were significantly higher in patients with CRC compared with healthy controls (p < 0.0001) and associated with clinical stages (p < 0.001). ROC analysis revealed that POSTN was a biomarker comparable to CEA, CA19.9, and CA72.4 to distinguish all CRC from healthy controls (AUC = 0.75). Moreover, POSTN retained its diagnostic ability for CEA-negative (AUC = 0.69) and CA19.9-negative CRC patients (AUC = 0.71). Survival analysis revealed that patients with lower serum POSTN had longer overall survival than those with high serum POSTN (p = 0.0146). Serum POSTN might be a novel diagnostic and prognostic biomarker for patients with CRC.
Evaluation of thyroid function in dogs suffering from recurrent flank alopecia.
Daminet, S; Paradis, M
2000-01-01
Thyroid function was assessed in euthyroid dogs (n = 20), dogs suffering from canine recurrent flank alopecia (CRFA, n = 18), and hypothyroid dogs (n = 21). Blood samples obtained from all dogs in each group were assayed for total thyroxine (TT4), thyrotropin (TSH), and thyroglobulin autoantibody (TgAA) serum concentrations. Total T4 and TSH serum concentrations were significantly decreased and increased, respectively, in the hypothyroid group compared with the other 2 groups. No significant differences in TT4 and TSH serum values were found between the euthyroid and CRFA groups. Thyroglobulin autoantibodies were detected in 10, 11.1, and 61.9% of euthyroid dogs, dogs with CRFA, and hypothyroid dogs, respectively. In conclusion, dogs suffering from CRFA have a normal thyroid function, and the determination of TT4 and TSH serum concentrations allows differentiation of these dogs from dogs with hypothyroidism, in most cases. Occasionally, the 2 diseases can be concomitant. PMID:10992988
Khan, Muhammad Jaseem; Ahmed, Basir; Ahmed, Saeed; Khan, Momin
2016-04-01
To evaluate the effect of fatty meal on intestinal alkaline phosphatase. The cross-sectional study was conducted at Khyber Medical University, Peshawar, Pakistan from March to April 2014 and comprised young healthy individuals 18-25 years of age. Whole blood samples were collected from the subjects in ethylenediaminetetraacetic acid anti-coagulated and plane serum tubes. For blood group analysis, blood group anti sera were used, while for serum alkaline phosphatase, a chemistry analyser was used. Alkaline phosphatase levels in the blood before and after breakfast were compared. Of the 177 subjects, there were 139(78.5%) men and 38(21.4%) women. Mean fasting alkaline phosphatise level was 144.22+/-75.57, while mean random value was 174.15+/-96.70 (p=0.001). Serum alkaline phosphatise must be analysed in fasting state early in the morning.
Bortoliero, André Luiz; Bonametti, Ana Maria; Morimoto, Helena Kaminami; Matsuo, Tiemi; Reiche, Edna Maria Vissoci
2006-01-01
A cross-sectional study was carried out among 996 volunteer blood donors enrolled from May 1999 to December 1999 to determine the seroprevalence of hepatitis E virus (HEV) infection among volunteer blood donors of the Regional Blood Bank of Londrina, State of Paraná, Brazil, and to evaluate whether the rate of seroprevalence of IgG anti-HEV antibodies is associated with sociodemographic variables and with seropositivity for hepatitis A virus (HAV) infection. All participants answered the questionnaire regarding the sociodemographic characteristics. Serum samples were tested for IgG antibodies to HEV (anti-HEV) by an enzyme linked immunoassay (ELISA). All serum samples positive for anti-HEV IgG and 237 serum samples negative for anti-HEV were also assayed for IgG anti-HAV antibodies by ELISA. Anti-HEV IgG was confirmed in 23/996 samples, resulting in a seroprevalence of 2.3% for HEV infection, similar to previous results obtained in developed countries. No significant association was found between the presence of anti-HEV IgG antibodies and the sociodemographic variables including gender, age, educational level, rural or urban areas, source of water, and sewer system (p > 0.05). Also, no association with seropositivity for anti-HAV IgG antibodies was observed (p > 0.05). Although this study revealed a low seroprevalence of HEV infection in the population evaluated, the results showed that this virus is circulating among the population from Londrina, South Brazil, and point out the need of further studies to define the clinical and epidemiological importance of HEV infection and to identify additional risk factors involved in the epidemiology and pathogenesis of this infection in this population.
Aubry, Maite; Roche, Claudine; Dupont-Rouzeyrol, Myrielle; Aaskov, John; Viallon, Jérôme; Marfel, Maria; Lalita, Paul; Elbourne-Duituturaga, Salanieta; Chanteau, Suzanne; Musso, Didier; Pavlin, Boris I; Harrison, Dustin; Kool, Jacob L; Cao-Lormeau, Van-Mai
2012-09-01
In Pacific Island Countries (PICs) the epidemiology of dengue is characterized by long-term transmission of a single dengue virus (DENV) serotype. The emergence of a new serotype in one island country often indicates major outbreaks with this serotype will follow in other PICs. Filter paper (FP) cards on which whole blood or serum from dengue suspected patients had been dried was evaluated as a method for transportation of this material by standard mail delivery throughout the Pacific. Twenty-two FP-dried whole blood samples collected from patients in New Caledonia and Wallis & Futuna Islands, during DENV-1 and DENV-4 transmission, and 76 FP-dried sera collected from patients in Yap State, Majuro (Republic of Marshall Islands), Tonga and Fiji, before and during outbreaks of DENV-2 in Yap State and DENV-4 in Majuro, were tested for the presence of DENV RNA, by serotype specific RT-PCR, at the Institut Louis Malardé in French Polynesia. The serotype of DENV could be determined, by a variety of RT-PCR procedures, in the FP-dried samples after more than three weeks of transport at ambient temperatures. In most cases, the sequencing of the envelope gene to genotype the viruses also was possible. The serotype and genotype of DENV can be determined from FP-dried serum or whole blood samples transported over thousands of kilometers at ambient, tropical, temperatures. This simple and low-cost approach to virus identification should be evaluated in isolated and resource poor settings for surveillance for a range of significant viral diseases. Copyright © 2012. Published by Elsevier B.V.
Singha, Harisankar; Malik, Praveen; Goyal, Sachin K; Khurana, Sandip K; Mukhopadhyay, Chiranjay; Eshwara, Vandana K; Singh, Raj K
2014-01-01
To express truncated TssB protein of Burkholderia mallei and to evaluate its diagnostic efficacy for serological detection of glanders among equines. In an attempt to develop recombinant protein based enzyme-linked immunosorbent assay (ELISA), N-terminal 200 amino acid sequences of B. mallei TssB protein-a type 6 secretory effector protein--were expressed in prokaryotic expression system. Diagnostic potential of recombinant TssB protein was evaluated in indirect ELISA using a panel of glanders positive (n = 49), negative (n = 30), and field serum samples (n = 1811). Cross-reactivity of the assay was assessed with equine disease control serum and human melioidosis positive serum. In comparison to CFT, diagnostic sensitivity and specificity of ELISA were 99.7% and 100%, respectively. The indirect ELISA method using the truncated TssB offered safer and more rapid and efficient means of serodiagnosis of glanders in equines. These data highlight the use of TssB as potential diagnostic antigen for serological diagnosis of glanders.
Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.
Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan
2018-01-01
Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.
microRNA-371a-3p as informative biomarker for the follow-up of testicular germ cell cancer patients.
van Agthoven, Ton; Eijkenboom, Wil M H; Looijenga, Leendert H J
2017-08-01
α-fetoprotein (AFP) and human chorionic gonadotropin subunit beta (B-HCG) are informative serum biomarkers for the primary diagnosis and follow-up of testicular germ cell cancer (TGCC) patients. About 20% of TGCC patients with a non-seminoma (NS) and about 80% with a seminoma (SE) are, however, negative for these biomarkers. Embryonic stem cell microRNAs (miRs) may serve as promising alternative serum biomarkers. Here we investigated a retrospective series of serum samples from selected TGCC patients who developed a relapse in time to test the possible additional value of the serum-based ampTSmiR test compared to the conventional serum-based protein biomarkers for follow-up. We investigated 261 retrospective serum samples of six selected fully evaluated TGCC patients with a proven relapse using the ampTSmiR test for miR-371a-3p, miR-373-3p, and miR-367-3p and compared the results to those of the conventional protein biomarkers. At primary diagnosis, elevated serum B-HCG, AFP and LDH levels were found to be informative in 4/6, 3/6 and 3/6 patients, respectively. At primary diagnosis the levels of miR-371a-3p and miR-373-3p were elevated in 4/4, and miR-367-3p in 3/4 patients. For two cases no starting serum sample was available for retrospective miR analysis. Residual disease (overlooked by histopathological examination) was detected in one case by miR-371a-3p only. The miR-371a-3p level was increased in one patient two months before detection of an intracranial metastasis. B-HCG was informative in 3/4 and the ampTSmiR test in 4/4 patients with a relapse or residual disease. None of the biomarkers were informative for the detection of residual mature teratoma. The ampTSmiR test is more sensitive than the conventional TGCC protein biomarkers for the detection of residual disease and relapse, excluding mature teratoma.
Cai, Yu-Chun; Chen, Shao-Hong; Tian, Li-Guang; Chu, Yan-Hong; Lu, Yan; Chen, Mu-Xin; Ai, Lin; Zhou, Yang; Chen, Jia-Xu
2014-02-01
To establish A1E3 and B1C4 monoclonal antibody-based ELISA for detecting circulating antigen of Schistosoma japonicum and explore its application value in the field. The characteristics of A1E3 and B1C4 monoclonal antibodies were analyzed by SDS-PAGE and Western blotting. The SEA-based ELISA was used to evaluate the titers of A1E3 and B1C4. The orthogonal test was used to determine the best concentration of coating antibody B1C4 and optimal working concentration of A1E3-HRP. Under the optimal conditions, the serum samples of 20 acute schistosomiasis cases, 46 chronic schistosomiasis cases, and 20 control sera were tested to evaluate its detection sensitivity and specificity. Seventy-two antibody positive serum samples from Jiangling County of Hubei Province were detected and compared to a commercially available ELISA kit, to evaluate the detection effects of this method. The results of SDS-PAGE demonstrated that the purified A1E3 and B1C4 contained a clear heavy chain with molecular weight of 88,000 and 52,000 respectively and had the same light chain with molecular weight of 20,000; while Western blotting demonstrated that A1E3 and B1C4 could be recognized by SEA and serum samples of acute schistosomiasis cases. The SEA-based ELISA demonstrated the titers of B1C4 and A1E3 were 1:10(5) and 1:30,000, respectively. The serum samples from all the acute cases and 86.9% of the chronic cases showed a positive reaction. All of the control sera from healthy persons gave a negative response. The positive rates of the double monoclonal antibody ELISA and commercial ELISA for detecting the circulating antigen were 45.8% and 43.1% respectively, and there was no significant difference between the results of the two methods. A1E3 and B1C4 monoclonal antibody-based ELISA is established successfully. It exhibits a high sensitivity and specificity in detecting circulating antigen of Schistosoma japonicum.
Baillargeon, Paul; Arango-Sabogal, Juan C; Wellemans, Vincent; Fecteau, Gilles
2017-04-01
The objective of this study was to determine if precolostral blood samples are useful to detect apparent fetal infections with bovine viral diarrhea (BVD) and infectious bovine rhinotracheitis (IBR) viruses. A convenience sample of 317 sera from 50 Canadian herds was used in the study. Antibody level was measured using 2 commercial IBR and BVD ELISA kits. Precolostral status of sera was confirmed on 304 samples using serum gamma-glutamyl transferase activity. Postcolostral serum samples yielded a higher proportion of positive results to IBR (OR = 86; 95% CI: 17.8 to 415.7) and BVD (OR = 199.3; 95% CI: 41.7 to 952.3) than did precolostral samples. All positive precolostral serum samples ( n = 7 of 304) originated from calves born to vaccinated cows. Postcolostral positive serum samples ( n = 11 of 13) originated mostly (60%) from calves born to non-vaccinated cows. Precolostral serum sampling can detect apparent fetal infections in a herd.
Nakano, Sachie; Tsukimura, Takahiro; Togawa, Tadayasu; Ohashi, Toya; Kobayashi, Masahisa; Takayama, Katsuyoshi; Kobayashi, Yukuharu; Abiko, Hiroshi; Satou, Masatsugu; Nakahata, Tohru; Warnock, David G.; Sakuraba, Hitoshi; Shibasaki, Futoshi
2015-01-01
We developed an immunochromatography-based assay for detecting antibodies against recombinant α-galactosidase A proteins in serum. The evaluation of 29 serum samples from Fabry patients, who had received enzyme replacement therapy with agalsidase alpha and/or agalsidase beta, was performed by means of this assay method, and the results clearly revealed that the patients exhibited the same level of antibodies against both agalsidase alpha and agalsidase beta, regardless of the species of recombinant α-galactosidase A used for enzyme replacement therapy. A conventional enzyme-linked immunosorbent assay supported the results. Considering these, enzyme replacement therapy with agalsidase alpha or agalsidase beta would generate antibodies against the common epitopes in both agalsidase alpha and agalsidase beta. Most of the patients who showed immunopositive reaction exhibited classic Fabry phenotype and harbored gene mutations affecting biosynthesis of α-galactosidase A. As immunochromatography is a handy and simple assay system which can be available at bedside, this assay method would be extremely useful for quick evaluation or first screening of serum antibodies against agalsidase alpha or agalsidase beta in Fabry disease with enzyme replacement therapy. PMID:26083343
Zhu, Jing-Cheng; Si, Meng-Ya; Li, Ya-Zhen; Chen, Huan-Zhu; Fan, Zhi-Cheng; Xie, Qing-Dong; Jiao, Xiao-Yang
2017-09-01
The aim of this study was to evaluate the clinical significance of circulating tight junction (TJ) proteins as biomarkers reflecting of leukaemia central nervous system (CNS) metastasis. TJs [claudin5 (CLDN5), occludin (OCLN) and ZO-1] concentrations were measured in serum and cerebrospinal fluid (CSF) samples obtained from 45 leukaemia patients. Serum ZO-1 was significantly higher (p < 0.05), but CSF ZO-1 levels were not significantly higher in the CNS leukaemia (CNSL) compared to the non-CNSL. The CNSL patients also had a lower CLDN5/ZO1 ratio in both serum and CSF than in non-CNSL patients (p < 0.05). The TJ index was negatively associated with WBC CSF , ALB CSF and BBB values in leukaemia patients. Among all of the parameters studied, CLDN5 CSF had the highest specificity in discriminating between CNSL and non-CNSL patients. Therefore, analysing serum and CSF levels of CLDN5, OCLN and the CLDN5/ZO1 ratio is valuable in evaluating the potential of leukaemia CNS metastasis. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Barbosa, Priscila Oliveira; Pala, Daniela; Silva, Carla Teixeira; de Souza, Melina Oliveira; do Amaral, Joana Ferreira; Vieira, Renata Adrielle Lima; Folly, Gilce Andrezza de Freitas; Volp, Ana Carolina Pinheiro; de Freitas, Renata Nascimento
2016-06-01
The aim of the present study was to evaluate the effect of açai pulp (Euterpe oleracea Martius) intake on the prevention of oxidative damage by measuring the activity of antioxidant enzymes and biomarkers of protein oxidation in women. A nutritional intervention study was conducted with thirty-five healthy women who were asked to consume 200 g/d of açai pulp for 4 wk. Blood samples were collected, and blood pressure and anthropometric parameters were measured before and after the experimental period. Antioxidant enzymes, superoxide dismutase, catalase, glutathione, production of reactive oxygen species, and total antioxidant capacity were evaluated in polymorphonuclear cells. Serum concentration of protein carbonyl and sulfhydryl groups were also determined. The açai intake increased catalase activity, total antioxidant capacity, and reduced the production of reactive oxygen species. Furthermore, it reduced serum concentration of protein carbonyl and increased total serum sulfhydryl groups. These results show the antioxidant benefit of dietary açai for the healthy women included in the present study, and may increase understanding of the beneficial health properties of this fruit. Copyright © 2016 Elsevier Inc. All rights reserved.
Min, Li; Cheng, Jian-bo; Shi, Bao-lu; Yang, Hong-jian; Zheng, Nan; Wang, Jia-qi
2015-06-01
Heat stress affects feed intake, milk production, and endocrine status in dairy cows. The temperature-humidity index (THI) is employed as an index to evaluate the degree of heat stress in dairy cows. However, it is difficult to ascertain whether THI is the most appropriate measurement of heat stress in dairy cows. This experiment was conducted to investigate the effects of heat stress on serum insulin, adipokines (leptin and adiponectin), AMP-activated protein kinase (AMPK), and heat shock signal molecules (heat shock transcription factor (HSF) and heat shock proteins (HSP)) in dairy cows and to research biomarkers to be used for better understanding the meaning of THI as a bioclimatic index. To achieve these objectives, two experiments were performed. The first experiment: eighteen lactating Holstein dairy cows were used. The treatments were: heat stress (HS, THI average=81.7, n=9) and cooling (CL, THI average=53.4, n=9). Samples of HS were obtained on August 16, 2013, and samples of CL were collected on April 7, 2014 in natural conditions. The second experiment: HS treatment cows (n=9) from the first experiment were fed for 8 weeks from August 16, 2013 to October 12, 2013. Samples for moderate heat stress, mild heat stress, and no heat stress were obtained, respectively, according to the physical alterations of the THI. Results showed that heat stress significantly increased the serum adiponectin, AMPK, HSF, HSP27, HSP70, and HSP90 (P<0.05). Adiponectin is strongly associated with AMPK. The increases of adiponectin and AMPK may be one of the mechanisms to maintain homeostasis in heat-stressed dairy cows. When heat stress treatment lasted 8 weeks, a higher expression of HSF and HSP70 was observed under moderate heat stress. Serum HSF and HSP70 are sensitive and accurate in heat stress and they could be potential indicators of animal response to heat stress. We recommend serum HSF and HSP70 as meaningful biomarkers to supplement the THI and evaluate moderate heat stress in dairy cows in the future.
Min, Li; Cheng, Jian-bo; Shi, Bao-lu; Yang, Hong-jian; Zheng, Nan; Wang, Jia-qi
2015-01-01
Heat stress affects feed intake, milk production, and endocrine status in dairy cows. The temperature-humidity index (THI) is employed as an index to evaluate the degree of heat stress in dairy cows. However, it is difficult to ascertain whether THI is the most appropriate measurement of heat stress in dairy cows. This experiment was conducted to investigate the effects of heat stress on serum insulin, adipokines (leptin and adiponectin), AMP-activated protein kinase (AMPK), and heat shock signal molecules (heat shock transcription factor (HSF) and heat shock proteins (HSP)) in dairy cows and to research biomarkers to be used for better understanding the meaning of THI as a bioclimatic index. To achieve these objectives, two experiments were performed. The first experiment: eighteen lactating Holstein dairy cows were used. The treatments were: heat stress (HS, THI average=81.7, n=9) and cooling (CL, THI average=53.4, n=9). Samples of HS were obtained on August 16, 2013, and samples of CL were collected on April 7, 2014 in natural conditions. The second experiment: HS treatment cows (n=9) from the first experiment were fed for 8 weeks from August 16, 2013 to October 12, 2013. Samples for moderate heat stress, mild heat stress, and no heat stress were obtained, respectively, according to the physical alterations of the THI. Results showed that heat stress significantly increased the serum adiponectin, AMPK, HSF, HSP27, HSP70, and HSP90 (P<0.05). Adiponectin is strongly associated with AMPK. The increases of adiponectin and AMPK may be one of the mechanisms to maintain homeostasis in heat-stressed dairy cows. When heat stress treatment lasted 8 weeks, a higher expression of HSF and HSP70 was observed under moderate heat stress. Serum HSF and HSP70 are sensitive and accurate in heat stress and they could be potential indicators of animal response to heat stress. We recommend serum HSF and HSP70 as meaningful biomarkers to supplement the THI and evaluate moderate heat stress in dairy cows in the future. PMID:26055916
Biomonitoring Hexamethylene diisocyanate (HDI) exposure based on serum levels of HDI-specific IgG.
Wisnewski, Adam V; Stowe, Meredith H; Nerlinger, Abby; Opare-Addo, Paul; Decamp, David; Kleinsmith, Christopher R; Redlich, Carrie A
2012-10-01
Isocyanate chemicals essential for polyurethane production are widely used industrially, and are increasingly found in consumer products. Asthma and other adverse health effects of isocyanates are well-documented and exposure surveillance is crucial to disease prevention. Hexamethylene diisocyanate (HDI)-specific serum immunoglobulin G (IgG) was evaluated as an exposure biomarker among workers at a US Air Force Air Logistics Center, which includes a large aircraft maintenance facility. HDI-specific IgG (HDI-IgG) titers in serum samples (n = 74) were measured using an enzyme-linked immunosorbent assay based upon the biuret form of HDI conjugated to human albumin. Information on personal protective equipment (PPE), work location/tasks, smoking, asthma history, basic demographics, and HDI skin exposure was obtained through questionnaire. HDI-specific serum IgG levels were elevated in n = 17 (23%) of the workers studied. The prevalence and/or end-titer of the HDI-IgG was significantly (P < 0.05) associated with specific job titles, self-reported skin exposure, night-shift work, and respirator use, but not atopy, asthma, or other demographic information. The highest titers were localized to specific worksites (C-130 painting), while other worksites (generator painting) had no or few workers with detectable HDI-IgG. HDI-specific immune responses (IgG) provide a practical biomarker to aid in exposure surveillance and ongoing industrial hygiene efforts. The strategy may supplement current air sampling approaches, which do not assess exposures via skin, or variability in PPE use or effectiveness. The approach may also be applicable to evaluating isocyanate exposures in other settings, and may extend to other chemical allergens.
Evaluation of pre transplant T-cell activation status by soluble CD 30 determination.
Abbas, Khawar; Muzaffar, Rana; Zafar, Mirza Naqi; Mubarak, Muhammad; Naqvi, Syed Ali Anwar; Rizvi, Syed Adibul Hassan
2009-04-01
To evaluate the utility of serum CD30 (sCD30) levels as predictor of early acute graft rejection in live related renal transplant programme. This prospective study included 50 consecutive renal transplant recipients who received their first live related renal allograft at the Sindh Institute of Urology and Transplantation (SIUT) between October 2006 and March 2007. Blood samples were obtained one day before transplantation and on the third and fourteenth posttransplant days. Blood samples were also obtained from 50, age and sex matched healthy control individuals. Levels of serum sCD30 were measured by Enzyme Linked Immunosorbent Assay (ELISA). Donor-recipient blood group matching was identical in all patients. Pre-transplant lymphocyte crossmatch for T and B cells was negative, and panel reactive antibodies (PRA) were 0% for all recipients. The mean age of recipients was 31.6 +/- 10.23 years (range 5 to 55 years), while mean donor age was 32.74 +/- 8.48 years (range 21-50 years). Eleven (22%) recipients and donors were HLA identical while remaining (78%) were one haplotype match. Average serum sCD30 pre-transplant levels (37.8 +/- 4.97U/ml) were significantly higher than those of healthy individual's mean value of 8.48 +/- 4.97 U/ml, (P = 0.001). Eight (16%) patients developed acute rejection episode during this follow up period. Rejections were described and classified according to BANFF 97 classification. In this small single center study the serum levels of sCD30 did not show any significant difference between rejection and non rejection group in our transplant population.
Piskun, Caroline M.; Muthuswamy, Anantharaman; Huelsmeyer, Michael K.; Thompson, Victoria; Stein, Timothy J.
2011-01-01
Osteosarcoma is an aggressive malignancy of the bone and an increase in serum alkaline phosphatase concentration has clinical prognostic value in both humans and canines. Increased serum alkaline phosphatase concentration at the time of diagnosis has been associated with poorer outcomes for osteosarcoma patients. The biology underlying this negative prognostic factor is poorly understood. Given that activation of the Wnt signaling pathway has been associated with alkaline phosphatase expression in osteoblasts, we hypothesized that the Wnt/β-catenin signaling pathway would be differentially activated in osteosarcoma tissue based on serum ALP status. Archived canine osteosarcoma samples and primary canine osteosarcoma cell lines were used to evaluate the status of Wnt/β-catenin signaling pathway activity through immunohistochemical staining, western immunoblot analyses, quantitative reverse-transcription polymerase chain reaction, and a Wnt-responsive promoter activity assay. We found no significant difference in β-catenin expression or activation between OSA populations differing in serum ALP concentration. Pathway activity was mildly increased in the primary OSA cell line generated from a patient with increased serum ALP compared to the normal serum ALP OSA cell line. Further investigation into the mechanisms underlying differences in serum ALP concentration is necessary to improve our understanding of the biological implications of this negative prognostic indicator. PMID:22022527
Shi, Xiao-Lei; Gu, Jin-Yang; Zhang, Yue; Han, Bing; Xiao, Jiang-Qiang; Yuan, Xian-Wen; Zhang, Ning; Ding, Yi-Tao
2011-01-01
AIM: To investigate whether the function of hepatocytes co-cultured with bone marrow mesenchymal stem cells (MSCs) could be maintained in serum from acute-on-chronic liver failure (ACLF) patients. METHODS: Hepatocyte supportive functions and cytotoxicity of sera from 18 patients with viral hepatitis B-induced ACLF and 18 healthy volunteers were evaluated for porcine hepatocytes co-cultured with MSCs and hepatocyte mono-layered culture, respectively. Chemokine profile was also examined for the normal serum and liver failure serum. RESULTS: Hepatocyte growth factor (HGF) and Tumor necrosis factor; tumor necrosis factor (TNF)-α were remarkably elevated in response to ACLF while epidermal growth factor (EGF) and VEGF levels were significantly decreased. Liver failure serum samples induced a higher detachment rate, lower viability and decreased liver support functions in the homo-hepatocyte culture. Hepatocytes co-cultured with MSCs could tolerate the cytotoxicity of the serum from ACLF patients and had similar liver support functions compared with the hepatocytes cultured with healthy human serum in vitro. In addition, co-cultured hepatocytes maintained a proliferative capability despite of the insult from liver failure serum. CONCLUSION: ACLF serum does not impair the cell morphology, viability, proliferation and overall metabolic capacities of hepatocyte co-cultured with MSCs in vitro. PMID:21633639
Influenza A Virus Surveillance Based on Pre-Weaning Piglet Oral Fluid Samples.
Panyasing, Y; Goodell, C; Kittawornrat, A; Wang, C; Levis, I; Desfresne, L; Rauh, R; Gauger, P C; Zhang, J; Lin, X; Azeem, S; Ghorbani-Nezami, S; Yoon, K-J; Zimmerman, J
2016-10-01
Influenza A virus (IAV) surveillance using pre-weaning oral fluid samples from litters of piglets was evaluated in four ˜12 500 sow and IAV-vaccinated, breeding herds. Oral fluid samples were collected from 600 litters and serum samples from their dams at weaning. Litter oral fluid samples were tested for IAV by virus isolation, quantitative reverse transcription-polymerase chain reaction (qRT-PCR), RT-PCR subtyping and sequencing. Commercial nucleoprotein (NP) enzyme-linked immunosorbent assay (ELISA) kits and NP isotype-specific assays (IgM, IgA and IgG) were used to characterize NP antibody in litter oral fluid and sow serum. All litter oral fluid specimens (n = 600) were negative by virus isolation. Twenty-five oral fluid samples (25/600 = 4.2%) were qRT-PCR positive based on screening (Laboratory 1) and confirmatory testing (Laboratory 2). No hemagglutinin (HA) and neuraminidase (NA) gene sequences were obtained, but matrix (M) gene sequences were obtained for all qRT-PCR-positive samples submitted for sequencing (n = 18). Genetic analysis revealed that all M genes sequences were identical (GenBank accession no. KF487544) and belonged to the triple reassortant influenza A virus M gene (TRIG M) previously identified in swine. The proportion of IgM- and IgA-positive samples was significantly higher in sow serum and litter oral fluid samples, respectively (P < 0.01). Consistent with the extensive use of IAV vaccine, no difference was detected in the proportion of IgG- and blocking ELISA-positive sow serum and litter oral fluids. This study supported the use of oral fluid sampling as a means of conducting IAV surveillance in pig populations and demonstrated the inapparent circulation of IAV in piglets. Future work on IAV oral fluid diagnostics should focus on improved procedures for virus isolation, subtyping and sequencing of HA and NA genes. The role of antibody in IAV surveillance remains to be elucidated, but longitudinal assessment of specific antibody has the potential to provide information regarding patterns of infection, vaccination status and herd immunity. © 2014 Blackwell Verlag GmbH.
[Value of polymerase chain reaction in serum for the diagnosis of enteroviral meningitis].
Marque Juillet, S; Lion, M; Pilmis, B; Tomini, E; Dommergues, M-A; Laporte, S; Foucaud, P
2013-06-01
Enteroviruses (EV) are a common cause of aseptic meningitis in children. Virological diagnosis of EV meningitis is currently based on the detection of the viral genome in the cerebrospinal fluid (CSF). This study attempted to determine the correlation and the temporality of the polymerase chain reaction (PCR) assay in serum and CSF and to evaluate the possibility of diagnosing EV infection only on the serum PCR. The EV genome was sought by RT real-time PCR (Smart Cycler EV Primer and Probe Set(®), Cepheid) in CSF and serum, collected at the same time, for all children who underwent a lumbar puncture for suspected meningitis, between 1 June and 31 July 2010 at the Versailles Hospital. Forty-four patients were included in the study. EV infection was documented for 22 of them. In 10 patients, the EV genome was detected in CSF only; in 3 patients in serum only, and in 9 patients in both. Among patients with acute EV neurological infection, viremic children were significantly younger (1.6 months versus 5.8 years; P<0.001). Viremia was detected when the serum was sampled within 30 h after the beginning of symptoms. These results confirm previous reports of early and transient viremia in young children. This preliminary study shows the limits and added value of EV PCR in serum. It suggests that in some children and under certain conditions (age >3 months, clinical and biological compatibility with a viral infection, no previous antibiotic therapy, time from symptom onset to blood sampling <30 h, PCR in serum analyzed within 3h), PCR in serum, when positive, is a possible alternative. Therefore, it may be possible to diagnose EV infection without performing a lumbar puncture in a limited number of young children (11.4% of our suspected cases). This study needs to be reinforced by a multicenter study with a broader panel of patients. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Abellan, Rosario; Ventura, Rosa; Palmi, Ilaria; di Carlo, Simonetta; Bacosi, Antonella; Bellver, Montse; Olive, Ramon; Pascual, Jose Antonio; Pacifici, Roberta; Segura, Jordi; Zuccaro, Piergiorgio; Pichini, Simona
2008-11-04
Insulin-like growth factor-II (IGF-II), insulin-like growth factor binding proteins (IGFBPs) -2 and -3 and C-terminal telopeptide of type I collagen (ICTP) have been proposed, among others, as indirect biomarkers of the recombinant human growth hormone misuse in sport. An extended intra- and inter-laboratory validation of commercially available immunoassays for biomarkers detection was performed. ELISA assays for total IGF-II, IGFBP-2 and IGFBP-3 (IGF-II/ELISA1: DSLabs, IGFBP-2/ELISA2: Biosource, and IGFBP-3/ELISA3: BioSource) and an EIA assay for ICTP (ICTP/EIA: Orion Diagnostica) were evaluated. The inter- and intra-laboratory precision values were acceptable for all evaluated assays (maximum imprecision of 30% and 66% were found only for the lowest quality control samples of IGF-II and IGFBP-3). Correct accuracy was obtained for all inter-laboratory immunoassays and for IGFBP-2 intra-laboratory immunoassay. The range of concentrations found in serum samples under investigation was always covered by the calibration curves of the studied immunoassays. However, 11% and 15% of the samples felt below the estimated LOQ for IGF-II and ICTP, respectively, in the zone where lower precision was obtained. Although the majority of evaluated assays showed an overall reliability not always suitable for antidoping control analysis, relatively high concordances between laboratory results were obtained for all assays. Evaluated immunoassays were used to measure serum concentrations of IGF-II, IGFBP-2 and -3 and ICTP in elite athletes of various sport disciplines at different moments of the training season; in recreational athletes at baseline conditions and finally in sedentary individuals. Serum IGF-II was statistically higher both in recreational and elite athletes compared to sedentary individuals. Elite athletes showed lower IGFBP-2 and higher IGFBP-3 concentration with respect to recreational athletes and sedentary people. Among elite athletes, serum IGFBP-3 (synchronized swimming), and ICTP (rhythmic gymnastics) concentrations were sport-dependent. Over the training season, within athlete variability was observed for IGFBP-2 in case of taekwondo and IGFBP-2 and -3 in case of weightlifting. Variations due to those aspects should be taken in careful consideration in the hypothesis of setting reference concentration ranges for doping detection.
Sajid, Muhammad; Basheer, Chanbasha
2016-07-15
In present work, a new configuration of micro-solid phase extraction was introduced and termed as stir-bar supported micro-solid-phase extraction (SB-μ-SPE). A tiny stir-bar was packed inside the porous polypropylene membrane along with sorbent material and the edges of membrane sheet were heat sealed to secure the contents. The packing of stir-bar inside the μ-SPE device does not allow the device to stick with the wall or any corner of the sample vial during extraction, which is, however, a frequent observation in routine μ-SPE. Moreover, it enhances effective surface area of the sorbent exposed to sample solution through continuous agitation (motion and rotation). It also completely immerses the SB-μ-SPE device in the sample solution even for non-polar sorbents. Polychlorinated biphenyls (PCBs) were selected as model compounds and the method performance was evaluated in human serum samples. After extraction, samples were analyzed by gas chromatography mass spectrometry (GC-MS). The factors that affect extraction efficiency of SB-μ-SPE were optimized. Under optimum conditions, a good linearity (0.1-100ngmL(-1)) with coefficients of determinations ranging from 0.9868 to 0.9992 was obtained. Limits of detections were ranged between 0.003 and 0.047ngmL(-1). Acceptable values for inter-day (3.2-9.1%) and intra-day (3.1-7.2%) relative standard deviations were obtained. The optimized method was successfully applied to determine the concentration of PCB congeners in human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
AhR transcriptional activity in serum of Inuits across Greenlandic districts
Long, Manhai; Deutch, Bente; Bonefeld-Jorgensen, Eva C
2007-01-01
Background Human exposure to lipophilic persistent organic pollutants (POPs) including polychlorinated dibenzo-p-dioxins/furans (PCDDs/PCDFs), polychlorinated biphenyls (PCBs) and organochlorine pesticide is ubiquitous. The individual is exposed to a complex mixture of POPs being life-long beginning during critical developmental windows. Exposure to POPs elicits a number of species- and tissue-specific toxic responses, many of which involve the aryl hydrocarbon receptor (AhR). The aim of this study was to compare the actual level of integrated AhR transcriptional activity in the lipophilic serum fraction containing the actual POP mixture among Inuits from different districts in Greenland, and to evaluate whether the AhR transactivity is correlated to the bio-accumulated POPs and/or lifestyle factors. Methods The study included 357 serum samples from the Greenlandic districts: Nuuk and Sisimiut (South West Coast), Qaanaaq (North Coast) and Tasiilaq (East Coast). The bio-accumulated serum POPs were extracted by ethanol: hexane and clean-up on Florisil columns. Effects of the serum extract on the AhR transactivity was determined using the Hepa 1.12cR mouse hepatoma cell line carrying an AhR-luciferase reporter gene, and the data was evaluated for possible association to the serum levels of 14 PCB congeners, 10 organochlorine pesticide residues and/or lifestyle factors. Results In total 85% of the Inuit samples elicited agonistic AhR transactivity in a district dependent pattern. The median level of the AhR-TCDD equivalent (AhR-TEQ) of the separate genders was similar in the different districts. For the combined data the order of the median AhR-TEQ was Tasiilaq > Nuuk ≥ Sisimiut > Qaanaaq possibly being related to the different composition of POPs. In overall, the AhR transactivity was inversely correlated to the levels of sum POPs, age and/or intake of marine food. Conclusion i) We observed that the proportion of dioxin like (DL) compounds in the POP mixture was the dominating factor affecting the level of serum AhR transcriptional activity even at very high level of non DL-PCBs; ii) The inverse association between the integrated serum AhR transactivity and sum of POPs might be explained by the higher level of compounds antagonizing the AhR function probably due to selective POP bioaccumulation in the food chain. PMID:17956617
Kooshki, A; Samadipour, E; Akbarzadeh, R
2015-01-01
Background:Despite the high levels of inflammation in hemodialysis patients and the effects of diet on systemic inflammation, such as the development of atherosclerosis and cardiovascular disease, few studies have evaluated the relationship of macronutrients and antioxidants intake with serum C-reactive protein (CRP). Therefore, this study assessed the relationship between serum high sensitivity CRP (hs-CRP) with macronutrients and antioxidants intake and serum albumin. Methods:This cross-sectional study used census sampling to select 75 hemodialysis patients (35 men and 40 women) who attended the hemodialysis department of Vaseie Hospital of Sabzevar, Iran. After obtaining the written consent, all the patients were interviewed and dietary data was collected by using a semi-quantitative food frequency questionnaire including 160 food items. Diet analysis was performed with Nutritionist IV. Before being connected to the dialysis machine, 5 cc fasting blood samples were obtained from all participants and serum hs-CRP and albumin levels were measured. All the statistical analyses were conducted with SPSS -for Windows, version 16.0. Results:The patients’ mean body mass index was 20.09 ± 3.27 kg/ m2. The participants’ intake of antioxidants and all macronutrients, except for carbohydrates and proteins, was less than the standard levels. Moreover, the hs-CRP had significant inverse relationships with serum albumin (P=0.0001) and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy (P=0.002) and protein (P=0.0001). Conclusion:Our findings indicated hs-CRP levels of hemodialysis patients to have significant inverse relationships with serum albumin and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy and protein. PMID:28255396
Kooshki, A; Samadipour, E; Akbarzadeh, R
2015-01-01
Background: Despite the high levels of inflammation in hemodialysis patients and the effects of diet on systemic inflammation, such as the development of atherosclerosis and cardiovascular disease, few studies have evaluated the relationship of macronutrients and antioxidants intake with serum C-reactive protein (CRP). Therefore, this study assessed the relationship between serum high sensitivity CRP (hs-CRP) with macronutrients and antioxidants intake and serum albumin. Methods: This cross-sectional study used census sampling to select 75 hemodialysis patients (35 men and 40 women) who attended the hemodialysis department of Vaseie Hospital of Sabzevar, Iran. After obtaining the written consent, all the patients were interviewed and dietary data was collected by using a semi-quantitative food frequency questionnaire including 160 food items. Diet analysis was performed with Nutritionist IV. Before being connected to the dialysis machine, 5 cc fasting blood samples were obtained from all participants and serum hs-CRP and albumin levels were measured. All the statistical analyses were conducted with SPSS -for Windows, version 16.0. Results: The patients' mean body mass index was 20.09 ± 3.27 kg/ m2. The participants' intake of antioxidants and all macronutrients, except for carbohydrates and proteins, was less than the standard levels. Moreover, the hs-CRP had significant inverse relationships with serum albumin (P=0.0001) and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy (P=0.002) and protein (P=0.0001). Conclusion: Our findings indicated hs-CRP levels of hemodialysis patients to have significant inverse relationships with serum albumin and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy and protein.
Huh, Jung Wook; Kim, Sung Chun; Sohn, Insuk; Jung, Sin-Ho; Kim, Hee Cheol
2016-01-01
Background In this study, we established and validated a model for predicting prognosis of stage IIA colon cancer patients based on expression profiles of aptamers in serum. Methods Bloods samples were collected from 227 consecutive patients with pathologic T3N0M0 (stage IIA) colon cancer. We incubated 1,149 serum molecule-binding aptamer pools of clinical significance with serum from patients to obtain aptamers bound to serum molecules, which were then amplified and marked. Oligonucleotide arrays were constructed with the base sequences of the 1,149 aptamers, and the marked products identified above were reacted with one another to produce profiles of the aptamers bound to serum molecules. These profiles were organized into low- and high-risk groups of colon cancer patients based on clinical information for the serum samples. Cox proportional hazards model and leave-one-out cross-validation (LOOCV) were used to evaluate predictive performance. Results During a median follow-up period of 5 years, 29 of the 227 patients (11.9%) experienced recurrence. There were 212 patients (93.4%) in the low-risk group and 15 patients (6.6%) in the high-risk group in our aptamer prognosis model. Postoperative recurrence significantly correlated with age and aptamer risk stratification (p = 0.046 and p = 0.001, respectively). In multivariate analysis, aptamer risk stratification (p < 0.001) was an independent predictor of recurrence. Disease-free survival curves calculated according to aptamer risk level predicted through a LOOCV procedure and age showed significant differences (p < 0.001 from permutations). Conclusion Aptamer risk stratification can be a valuable prognostic factor in stage II colon cancer patients. PMID:26908450
Serum glycerophosphate levels are increased in Japanese men with type 2 diabetes.
Daimon, Makoto; Soga, Tomoyoshi; Hozawa, Atsushi; Oizumi, Toshihide; Kaino, Wataru; Takase, Kaoru; Karasawa, Shigeru; Jimbu, Yumi; Wada, Kiriko; Kameda, Wataru; Susa, Shinji; Kayama, Takamasa; Saito, Kaori; Tomita, Masaru; Kato, Takeo
2012-01-01
To identify metabolites showing changes in serum levels among Japanese male with diabetes. We performed metabolite profiling by coupling capillary electrophoresis with electrospray ionization time-of-flight mass spectrometry using fasting serum samples from Japanese male subjects with diabetes (n=17), impaired glucose tolerance (IGT; n=5) and normal glucose tolerance (NGT; n=14). Other than the expected differences in characteristics related to abnormal glucose metabolism, the percent body fat was significantly different among subjects with diabetes, IGT and NGT (27.3±6.2, 22.2±4.5 and 19.2±6.0%, respectively, p=0.0022). Therefore, percent body fat was considered as a possible confounding factor in subsequent analyses. Of 560 metabolites detected using our platform, the levels of 74 metabolites were quantified in all of the serum samples. Significant differences between diabetes and NGT were observed for 24 metabolites. The top-ranked metabolite was glycerol-3-phophate (glycerophosphate), which was significantly higher in subjects with diabetes than in those with NGT, even after Bonferroni correction for multiple testing (11.7±3.6 vs. 6.4±1.9 µM, respectively; corrected p=0.0222). Stepwise multiple regression analyses revealed that serum glycerophosphate levels were significantly correlated with 2-h plasma glucose after a 75-g oral glucose tolerance test (r=0.553, p=0.0005), independently of other characteristics, including FPG and HbA1c. Serum glycerophosphate levels were found to be elevated in Japanese men with diabetes, and correlated with 2-h PG, independent of FPG and HbA1c. Namely, serum glycerophosphate level at fasting condition can be a marker for predicting glucose intolerance. These results warrant further studies to evaluate the relevance of glycerophosphate in the pathophysiology of diabetes.
Abdelwahab, Mohamed; Loa, Chien Chang; Wu, Ching Ching; Lin, Tsang Long
2015-06-01
Nucleocapsid (N) protein gene of turkey coronavirus (TCoV) was expressed in a prokaryotic system and used to develop an enzyme-linked immunosorbent assay (ELISA) for detection of antibody to TCoV. Anti-TCoV hyperimmune turkey serum and normal turkey serum were used as positive or negative controls for optimization of the ELISA. Goat anti-turkey IgG (H+L) conjugated with horseradish peroxidase was used as detector antibody. Three hundred and twenty two turkey sera from the field were used to evaluate the performance of ELISA and determine the cut-off point of ELISA. The established ELISA was also examined with serum samples obtained from turkeys experimentally infected with TCoV. Those serum samples were collected at various time intervals from 1 to 63 days post-infection. The optimum conditions for differentiation between anti-TCoV hyperimmune serum and normal turkey serum were recombinant TCoV N protein concentration at 20 μg/ml, serum dilution at 1:800, and conjugate dilution at 1:10,000. Of the 322 sera from the field, 101 were positive for TCoV by immunofluorescent antibody assay (IFA). The sensitivity and specificity of the ELISA relative to IFA test were 86.0% and 96.8%, respectively, using the optimum cut-off point of 0.2 as determined by logistic regression method. Reactivity of anti-rotavirus, anti-reovirus, anti-adenovirus, or anti-enterovirus antibodies with the recombinant N protein coated on the ELISA plates was not detected. These results indicated that the established antibody-capture ELISA in conjunction with recombinant TCoV N protein as the coating protein can be utilized for detection of antibodies to TCoV in turkey flocks. Copyright © 2015 Elsevier B.V. All rights reserved.
Toxoplasma gondii in feral american minks at the Maullin river, Chile
USDA-ARS?s Scientific Manuscript database
American mink (Neovison vison) is a widely distributed invasive species in southern Chile. Thirty four feral minks were trapped at two distinct sites (rural and peri-urban), diet analyzed, and Toxoplasma gondii exposure compared using PCR and specific antibodies. Serum samples were evaluated using a...
Comparison of serum and plasma measurements of Müllerian inhibiting substance.
Merhi, Zaher O; Messerlian, Geralyn M; Minkoff, Howard; Eklund, Elizabeth E; Macura, Jerzy; Feldman, Joseph; Rodriguez, Carlos; Seifer, David B
2008-06-01
The authors sought to determine whether measurement of plasma Müllerian inhibiting substance (MIS) is a suitable substitute for measurement of serum MIS. Eighteen samples of serum and plasma were examined that were drawn simultaneously. Levels of MIS were measured with an ELISA kit, and plasma levels were studied in parallel to serum samples. A 98.5% correlation was found between serum and plasma MIS values.
Evaluation of the IMMULITE® 2000 CMV IgM assay
2012-01-01
Background Diagnosis of cytomegalovirus (CMV) infection is challenging because of the high rate of asymptomatic infection and the low specificity of associated symptoms and signs. As a result, laboratory testing is an essential aid in making an accurate diagnosis. The presence of CMV IgM is indicative of primary CMV infection. In pregnancy, diagnosis of primary infection is important because primary maternal infection increases fetal infection risk substantially. Fetal infection can result in serious sequelae ranging from neurological deficits to death. Diagnosis among the immunocompromised is also critical for the timely initiation of therapy that can reduce morbidity and mortality risk. Methods The IMMULITE® 2000 CMV IgM assay qualitatively detects CMV IgM antibodies in human serum or plasma to aid in the diagnosis of current or recent CMV infection. To determine expected values in apparently healthy subjects, 136 samples were tested. Reproducibility, normal range, and method comparison studies were also performed to evaluate the assay's performance. The assay's reproducibility was evaluated across three sites. Seven hundred and eighteen (n = 718) individual patient serum samples, which included samples from CMV IgM-positive (n = 109, determined by the Abbott IMx CMV or the Diamedix CMV IgM assays), pregnant (n = 210), HIV-positive (n = 30), immunosuppressed (n = 102), and transplant patients (n = 17) and from patients with potentially cross-reacting conditions (n = 136) were evaluated in the method comparison study. The positive, negative, and overall agreement between the IMMULITE 2000 CMV IgM assay and the VIDAS CMV IgM assay (predicate assay) were determined. Results The assay demonstrated excellent reproducibility with a total CV of less than 10%. The positive, negative, and overall agreement between the IMMULITE 2000 assay and the VIDAS assay were > 95% for the method comparison samples. Among potentially cross-reactive samples, the overall agreement between the two assays was 96%. Similarly, among the immunocompromised and pregnant subjects, the overall agreement was ~96% and ~97%, respectively. Conclusions The IMMULITE 2000 CMV IgM assay demonstrated excellent reproducibility, minimal cross-reactivity, and performance comparable to that of the VIDAS CMV IgM assay. It can aid in the diagnosis of acute CMV or recent CMV infection by qualitatively detecting the CMV IgM antibodies in human serum or plasma. PMID:22377002
Evaluation of the IMMULITE® 2000 CMV IgM assay.
Bal, Tricia A; Armstrong, Glenn; Han, Xiang Y
2012-02-29
Diagnosis of cytomegalovirus (CMV) infection is challenging because of the high rate of asymptomatic infection and the low specificity of associated symptoms and signs. As a result, laboratory testing is an essential aid in making an accurate diagnosis. The presence of CMV IgM is indicative of primary CMV infection. In pregnancy, diagnosis of primary infection is important because primary maternal infection increases fetal infection risk substantially. Fetal infection can result in serious sequelae ranging from neurological deficits to death. Diagnosis among the immunocompromised is also critical for the timely initiation of therapy that can reduce morbidity and mortality risk. The IMMULITE® 2000 CMV IgM assay qualitatively detects CMV IgM antibodies in human serum or plasma to aid in the diagnosis of current or recent CMV infection. To determine expected values in apparently healthy subjects, 136 samples were tested. Reproducibility, normal range, and method comparison studies were also performed to evaluate the assay's performance. The assay's reproducibility was evaluated across three sites. Seven hundred and eighteen (n = 718) individual patient serum samples, which included samples from CMV IgM-positive (n = 109, determined by the Abbott IMx CMV or the Diamedix CMV IgM assays), pregnant (n = 210), HIV-positive (n = 30), immunosuppressed (n = 102), and transplant patients (n = 17) and from patients with potentially cross-reacting conditions (n = 136) were evaluated in the method comparison study. The positive, negative, and overall agreement between the IMMULITE 2000 CMV IgM assay and the VIDAS CMV IgM assay (predicate assay) were determined. The assay demonstrated excellent reproducibility with a total CV of less than 10%. The positive, negative, and overall agreement between the IMMULITE 2000 assay and the VIDAS assay were > 95% for the method comparison samples. Among potentially cross-reactive samples, the overall agreement between the two assays was 96%. Similarly, among the immunocompromised and pregnant subjects, the overall agreement was ~96% and ~97%, respectively. The IMMULITE 2000 CMV IgM assay demonstrated excellent reproducibility, minimal cross-reactivity, and performance comparable to that of the VIDAS CMV IgM assay. It can aid in the diagnosis of acute CMV or recent CMV infection by qualitatively detecting the CMV IgM antibodies in human serum or plasma.
Rezende, Vinícius Marcondes; Rivellis, Ariane Julio; Gomes, Melissa Medrano; Dörr, Felipe Augusto; Novaes, Mafalda Megumi Yoshinaga; Nardinelli, Luciana; Costa, Ariel Lais de Lima; Chamone, Dalton de Alencar Fisher; Bendit, Israel
2013-01-01
Objective The goal of this study was to monitor imatinib mesylate therapeutically in the Tumor Biology Laboratory, Department of Hematology and Hemotherapy, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo (USP). A simple and sensitive method to quantify imatinib and its metabolite (CGP74588) in human serum was developed and fully validated in order to monitor treatment compliance. Methods The method used to quantify these compounds in serum included protein precipitation extraction followed by instrumental analysis using high performance liquid chromatography coupled with mass spectrometry. The method was validated for several parameters, including selectivity, precision, accuracy, recovery and linearity. Results The parameters evaluated during the validation stage exhibited satisfactory results based on the Food and Drug Administration and the Brazilian Health Surveillance Agency (ANVISA) guidelines for validating bioanalytical methods. These parameters also showed a linear correlation greater than 0.99 for the concentration range between 0.500 µg/mL and 10.0 µg/mL and a total analysis time of 13 minutes per sample. This study includes results (imatinib serum concentrations) for 308 samples from patients being treated with imatinib mesylate. Conclusion The method developed in this study was successfully validated and is being efficiently used to measure imatinib concentrations in samples from chronic myeloid leukemia patients to check treatment compliance. The imatinib serum levels of patients achieving a major molecular response were significantly higher than those of patients who did not achieve this result. These results are thus consistent with published reports concerning other populations. PMID:23741187
Dervishi, Elda; Zhang, Guanshi; Hailemariam, Dagnachew; Dunn, Suzana M; Ametaj, Burim N
2016-01-01
Failure to expel fetal membranes within 24 h of calving is a pathological condition defined as retained placenta (RP). The objective of this investigation was to evaluate whether there are alterations in several selected serum variables related to innate immunity and carbohydrate and lipid metabolism that precede occurrence of RP in transition Holstein dairy cows. One hundred multiparous Holstein dairy cows were involved in the study. Blood samples were collected from the coccygeal vein during the -8 to +4 wks around parturition, once per week before the morning feeding. Six healthy control cows (CON) and 6 cows with RP were selected and serum samples at -8, -4, time of diagnosis of disease, and +4 wks relative to parturition were used for analyses. All samples were analyzed for lactate, non-esterified fatty acids (NEFA), β-hydroxybutyrate (BHBA), interleukin-1 (IL-1), interleukin-6 (IL-6), tumor necrosis factor (TNF), haptoglobin (Hp), and serum amyloid A (SAA). Cows with RP had greater concentrations of serum lactate, IL-1, IL-6, TNF, and SAA in comparison with CON cows. Intriguingly, elevated concentrations of all five variables were observed at -8 and -4 wks before the occurrence of RP compared to healthy cows. Cows with RP also had lower DMI and milk production vs CON animals; however milk composition was not affected by RP. Cows with RP showed an activated innate immunity 8 wks prior to diagnosis of disease. Overall results suggest that serum IL-1, IL- 6, and TNF, and lactate can be used as screening biomarkers to indicate cows that might have health issues during the transition period.
Harrington, Chris F; McKibbin, Craig; Rahanu, Monika; Langton, David; Taylor, Andrew
2017-05-01
Background Patients with metal-on-metal hip replacements require testing for cobalt and chromium. There may also be a need to test for titanium, which is used in the construction of the femoral stem in total hip replacements. It is not possible to use quadrupole inductively coupled plasma mass spectrometry due to interferences. Methods Titanium was measured using inductively coupled plasma optical emission spectroscopy using the emission line at 336.1 nm and Y (internal standard) at 371.0 nm. Internal quality control materials were prepared for blood and serum and concentrations assigned using a sector field-inductively coupled plasma mass spectrometer. A candidate whole blood certified reference material was also evaluated. Results The method had detection and quantitation limits of 0.6 and 1.9 µg/L, respectively. The respective bias (%) and measurement uncertainty ( U) (k = 2) were 3.3% and 2.0 µg/L (serum) and - 1.0% and 1.4 µg/L (whole blood). The respective repeatability and intermediate precision (%) were 5.1% and 10.9% (serum) and 2.4% and 8.6% (whole blood). The concentration of titanium was determined in patients' samples, serum (median = 2.4 µg/L, n = 897) and whole blood (median = 2.4 µg/L, n = 189). Serum is recommended for monitoring titanium in patients, since the concentration is higher than in whole blood and the matrix less problematic. In hip fluid samples, the concentrations were much higher (mean 58.5 µg/L, median 5.1 µg/L, n = 83). Conclusions A method based on inductively coupled plasma optical emission spectroscopy was developed and validated for measuring titanium in clinical samples.
2004-01-01
Abstract Pancreatitis is recognized as an important cause for morbidity and mortality in cats, but diagnosis remains difficult in many cases. As a first step in trying to identify a better diagnostic tool for feline pancreatitis the objective of this project was to develop and analytically validate a radioimmunoassay for the measurement of feline pancreatic lipase immunoreactivity (fPLI). Feline pancreatic lipase (fPL) was purified from pancreatic tissue and antiserum against fPL was raised in rabbits. Tracer was produced by iodination of fPL using the chloramine T method. A radioimmunoassay was established and analytically validated by determination of sensitivity, dilutional parallelism, spiking recovery, intra-assay variability, and interassay variability. A control range for fPLI in cat serum was established from 30 healthy cats using the central 95th percentile. The sensitivity of the assay was 1.2 μg/L. Observed to expected ratios for serial dilutions ranged from 98.8% to 164.3% for 3 different serum samples. Observed to expected ratios for spiking recovery ranged from 76.9% to 147.6% for 3 different serum samples. Coefficients of variation for intra- and interassay variability for 4 different serum samples were 10.1%, 4.5%, 2.2%, and 3.9% and 24.4%, 15.8%, 16.6%, and 21.3%, respectively. A reference range for fPLI was established as 1.2 to 3.8 μg/L. We conclude that the assay described is sensitive, accurate, and precise with limited linearity in the lower and limited reproducibility in the lower and higher end of the working range. Further studies to evaluate the clinical usefulness of this assay are needed and in progress. PMID:15581227
Evaluation of sample hemolysis in blood collected by S-Monovette using vacuum or aspiration mode.
Lippi, Giuseppe; Avanzini, Paola; Musa, Roberta; Sandei, Franca; Aloe, Rosalia; Cervellin, Gianfranco
2013-01-01
In vitro hemolysis can be induced by several biological and technical sources, and may be worsened by forced aspiration of blood in vacuum tubes. This study was aimed to compare the probability of hemolysis by drawing blood with a commercial evacuated blood collection tube, and S-Monovette used either in the "vacuum" or "aspiration" mode. The study population consisted in 20 healthy volunteers. A sample was drawn into 4.0 mL BD Vacutainer serum tube from a vein of one upper arm. Two other samples were drawn with a second venipuncture from a vein of the opposite arm, into 4.0 mL S-Monovette serum tubes, by both vacuum an aspiration modes. After separation, serum potassium, lactate dehydrogenase (LD) and hemolysis index (HI) were tested on Beckman Coulter DxC. In no case the HI exceed the limit of significant hemolysis. As compared with BD Vacutainer, no significant differences were observed for potassium and LD using S-Monovette with vacuum method. Significant increased values of both parameters were however found in serum collected into BD Vacutainer and S-Monovette by vacuum mode, compared to serum drawn by S-Monovette in aspiration mode. The mean potassium bias was 2.2% versus BD Vacutainer and 2.4% versus S-Monovette in vacuum mode, that of LD was 2.7% versus BD Vacutainer and 2.1% versus S-Monovette in vacuum mode. None of these variations exceeded the allowable total error. Although no significant macro-hemolysis was observed with any collection system, the less chance of producing micro-hemolysis by S-Monovette in aspiration mode suggest that this device may be used when a difficult venipuncture combined with the vacuum may increase the probability of spurious hemolysis.
Anti-signal recognition particle autoantibody ELISA validation and clinical associations.
Aggarwal, Rohit; Oddis, Chester V; Goudeau, Danielle; Fertig, Noreen; Metes, Ilinca; Stephens, Chad; Qi, Zengbiao; Koontz, Diane; Levesque, Marc C
2015-07-01
The aim of this study was to develop and validate a quantitative anti-signal recognition particle (SRP) autoantibody serum ELISA in patients with myositis and longitudinal association with myositis disease activity. We developed a serum ELISA using recombinant purified full-length human SRP coated on ELISA plates and a secondary antibody that bound human IgG to detect anti-SRP binding. Protein immunoprecipitation was used as the gold standard for the presence of anti-SRP. Serum samples from three groups were analysed: SRP(+) myositis subjects by immunoprecipitation, SRP(-) myositis subjects by immunoprecipitation and non-myositis controls. The ELISA's sensitivity, specificity, positive predictive value and negative predictive value were evaluated. Percentage agreement and test-retest reliability were assessed. Serial samples from seven SRP immunoprecipitation-positive subjects were also tested, along with serum muscle enzymes and manual muscle testing. Using immunoprecipitation, we identified 26 SRP(+) myositis patients and 77 SRP(-) controls (including 38 patients with necrotizing myopathy). Non-myositis control patients included SLE (n = 4) and SSc (n = 7) patients. Anti-SRP positivity by ELISA showed strong agreement (97.1%) with immunoprecipitation (κ = 0.94). The sensitivity, specificity, positive predictive value, and negative predictive value of the anti-SRP ELISA were 88, 100, 100 and 96, respectively. The area under the curve was 0.94, and test-retest reliability was strong (r = 0.91, P < 0.001). Serial samples showed that anti-SRP levels paralleled changes in muscle enzymes and manual muscle testing. We developed a quantitative ELISA for detecting serum anti-SRP autoantibodies and validated the assay in myositis. Longitudinal assessment of SRP levels by ELISA may be a useful biomarker for disease activity. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon
2017-11-30
The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The recovery of serum miRNA dry-spotted on FTA Elute cards by direct elution with water at high temperature was poor. However, serum miRNAs dry-spotted on the cards were isolated with about 40% yield when using QIAzol lysis reagent and recovery was improved remarkably (>80%) upon extraction from cards pre-treated with trehalose. miRNAs stored on the cards remained stable at room temperature and can be kept for prolonged periods. Furthermore, miRNAs could be similarly recovered from serum exosomes dry-spotted on the cards. Importantly, when using sera from gastric cancer (GC) patients, the miRNAs were efficiently recovered from trehalose pre-treated cards without affecting their representation. Collectively, we have demonstrated the potential of FTA Elute cards to archive serum and serum exosomal miRNAs, making it useful for biomarker discovery and diagnostics.
[Design and evaluation of DAVIH VIH-2].
Martín Alfonso, Dayamí; Silva Cabrera, Eladio; Pérez Guevara, María T; Díaz Herrera, Dervel F; Romero Martínez, Kenia; Díaz Torres, Héctor M; Lubián Caballero, Ana L; Ruiz Gutiérrez, Nancy; Ortiz Losada, Eva
2007-01-01
The results of the design and evaluation of DAVIH VIH-2 diagnosing system, an indirect Elisa for screening of HIV-2 antibodies, which uses a HIV-2 glycoprotein gp36 synthetic peptide in its solid phase, were exposed. In the system evaluation using WHO reference panels, 100% sensitivity, 99,81% specificity, 99,81% efficacy and very good concordance level (kappa = 0.978) were attained. Serum samples of 959 individuals with undetermined or negative results to the HIV-1 antibodies confirmation (DAVIH blot) were evaluated by the DAVIH VIH-2 system. Twenty four samples were reactive, six of which had confirmed HIV-2 antibodies. These results allowed recommending the introduction of this diagnostic kit in the HIV infection diagnosing algorithm in Cuba.
Serum levels of interleukin-6 are linked to the severity of the disease caused by Andes Virus.
Angulo, Jenniffer; Martínez-Valdebenito, Constanza; Marco, Claudia; Galeno, Héctor; Villagra, Eliecer; Vera, Lilian; Lagos, Natalia; Becerra, Natalia; Mora, Judith; Bermúdez, Andrea; Díaz, Janepsy; Ferrés, Marcela; López-Lastra, Marcelo
2017-07-01
Andes virus (ANDV) is the etiological agent of hantavirus cardiopulmonary syndrome in Chile. In this study, we evaluated the profile of the pro-inflammatory cytokines IL-1β, IL-12p70, IL-21, TNF-α, IFN-γ, IL-10 and IL-6 in serum samples of ANDV-infected patients at the time of hospitalization. The mean levels of circulating cytokines were determined by a Bead-Based Multiplex assay coupled with Luminex detection technology, in order to compare 43 serum samples of healthy controls and 43 samples of ANDV-infected patients that had been categorized according to the severity of disease. When compared to the controls, no significant differences in IL-1β concentration were observed in ANDV-infected patients (p = 0.9672), whereas levels of IL-12p70 and IL-21 were significantly lower in infected cases (p = <0.0001). Significantly elevated levels of TNF-α, IFN-γ, IL-10, and IL-6 were detected in ANDV-infected individuals (p = <0.0001, 0.0036, <0.0001, <0.0001, respectively). Notably, IL-6 levels were significantly higher (40-fold) in the 22 patients with severe symptoms compared to the 21 individuals with mild symptoms (p = <0.0001). Using multivariate regression models, we show that IL-6 levels has a crude OR of 14.4 (CI: 3.3-63.1). In conclusion, the serum level of IL-6 is a significant predictor of the severity of the clinical outcome of ANDV-induced disease.
Analysis of anhydrous glucose and human serum assisted by Raman spectroscopy
NASA Astrophysics Data System (ADS)
González, Naara; Cerecedo-Núñez, H. H.; Padilla-Sosa, P.; Flores, Aaron; May, Manuel; Basurto, Miguel; Alcántara, Gabriela; Muñiz, Omar
2017-02-01
Raman spectroscopy has been considered like a potentially important clinical tool for real-time diagnosis of disease and evaluation of living tissue, whit the proposal to development noninvasive glucose measurements in a near future, with lower power than other reported studies, in this work are reported experimental tests made with a excitation source of semiconductor laser of 785 nm and 35 mW power. Measurements were made to different glucose concentrations, with variation from 50 mg/dL to 6000 mg/dL. For this, three intervals with different ranges of concentration were analyzed, these tests were put into plastic sampling cells, making incise the beam vertically on sample. In the same way measurements to serum human are reported, for healthy volunteers had 12 hours fasting and non-fasting conditions, with it's corresponding values of glucose taken through a conventional glucometer. Freeze-dried human serum was poured on object-holder, in the case of human serum reconstitute, it was used container in which were previously kept samples. Nine spectra per test were obtained and subsequently average was calculated, the spectra were studied in a range of 500 to 1700 cm-1. This work explores the intensity variation of the bands of glucose in 1065 cm-1 and 1127 cm-1 as a function of glucose concentration. In the obtained results, there observes a behavior with positive slope in both substances, interrelation being observed between the measurements, being promissory for non-invasive measurement.
A round robin approach to the analysis of bisphenol a (BPA) in human blood samples
2014-01-01
Background Human exposure to bisphenol A (BPA) is ubiquitous, yet there are concerns about whether BPA can be measured in human blood. This Round Robin was designed to address this concern through three goals: 1) to identify collection materials, reagents and detection apparatuses that do not contribute BPA to serum; 2) to identify sensitive and precise methods to accurately measure unconjugated BPA (uBPA) and BPA-glucuronide (BPA-G), a metabolite, in serum; and 3) to evaluate whether inadvertent hydrolysis of BPA-G occurs during sample handling and processing. Methods Four laboratories participated in this Round Robin. Laboratories screened materials to identify BPA contamination in collection and analysis materials. Serum was spiked with concentrations of uBPA and/or BPA-G ranging from 0.09-19.5 (uBPA) and 0.5-32 (BPA-G) ng/mL. Additional samples were preserved unspiked as ‘environmental’ samples. Blinded samples were provided to laboratories that used LC/MSMS to simultaneously quantify uBPA and BPA-G. To determine whether inadvertent hydrolysis of BPA metabolites occurred, samples spiked with only BPA-G were analyzed for the presence of uBPA. Finally, three laboratories compared direct and indirect methods of quantifying BPA-G. Results We identified collection materials and reagents that did not introduce BPA contamination. In the blinded spiked sample analysis, all laboratories were able to distinguish low from high values of uBPA and BPA-G, for the whole spiked sample range and for those samples spiked with the three lowest concentrations (0.5-3.1 ng/ml). By completion of the Round Robin, three laboratories had verified methods for the analysis of uBPA and two verified for the analysis of BPA-G (verification determined by: 4 of 5 samples within 20% of spiked concentrations). In the analysis of BPA-G only spiked samples, all laboratories reported BPA-G was the majority of BPA detected (92.2 – 100%). Finally, laboratories were more likely to be verified using direct methods than indirect ones using enzymatic hydrolysis. Conclusions Sensitive and accurate methods for the direct quantification of uBPA and BPA-G were developed in multiple laboratories and can be used for the analysis of human serum samples. BPA contamination can be controlled during sample collection and inadvertent hydrolysis of BPA conjugates can be avoided during sample handling. PMID:24690217
Gruen, Margaret E.; Messenger, Kristen M.; Thomson, Andrea E.; Griffith, Emily H.; Aldrich, Lauren A.; Vaden, Shelly; Lascelles, BDX
2017-01-01
Degenerative joint disease is common in cats, with signs of pain frequently found on orthopedic examination and radiographs often showing evidence of disease. However, understanding of the pathophysiology of degenerative joint disease and associated pain remains limited. Several cytokines have been identified as having a role in pain in humans, but this has not been investigated in cats. The present study was performed to use a multiplex platform to evaluate the concentration of 19 cytokines and chemokines in serum samples obtained from cats with and without degenerative joint disease and associated pain. Samples from a total of 186 cats were analyzed, with cats representing a range of severity on radiographic and orthopedic evaluations and categorized by degenerative joint disease scores and pain scores. Results showed that cats with higher radiographic degenerative joint disease scores have higher serum concentrations of IL-4 and IL-8, while cats with higher orthopedic exam pain scores have higher concentrations of IL-8, IL-2, and TNF-α increased concentration of IL-8 in degenerative joint disease and pain may be confounded by the association with age. Discriminant analysis was unable to identify one or more cytokines that distinguish between groups of cats classified based on degenerative joint disease score category or pain score category. Finally, cluster analysis driven by analyte concentrations show separation of groups of cats, but features defining the groups remain unknown. Further studies are warranted to investigate any changes in cytokine concentrations in response to analgesic therapies, and further evaluate the elevations in cytokine concentrations found here, particularly focused on studies of local cytokines present in synovial fluid. PMID:28063477
Development of in-house serological methods for diagnosis and surveillance of chikungunya.
Galo, Saira Saborío; González, Karla; Téllez, Yolanda; García, Nadezna; Pérez, Leonel; Gresh, Lionel; Harris, Eva; Balmaseda, Ángel
2017-08-21
To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014-2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention's IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%-95.9%. Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease.
Development of in-house serological methods for diagnosis and surveillance of chikungunya
Galo, Saira Saborío; González, Karla; Téllez, Yolanda; García, Nadezna; Pérez, Leonel; Gresh, Lionel; Harris, Eva; Balmaseda, Ángel
2017-01-01
Objective To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. Methods Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014–2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention’s IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. Results All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%–95.9%. Conclusion Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease. PMID:28902269
Craig, A M; Blythe, L L; Rowe, K E; Lassen, E D; Barrington, R; Walker, K C
1992-12-01
Recent evidence concerning the pathogenesis of equine degenerative myeloencephalopathy indicated that low blood alpha-tocopherol values are a factor in the disease process. Variables that could be introduced by a veterinarian procuring, transporting, or storing samples were evaluated for effects on alpha-tocopherol concentration in equine blood. These variables included temperature; light; exposure to the rubber stopper of the evacuated blood collection tube; hemolysis; duration of freezing time, with and without nitrogen blanketing; and repeated freeze/thaw cycles. It was found that hemolysis caused the greatest change in high-performance liquid chromatography-measured serum alpha-tocopherol values, with mean decrease of 33% (P < 0.001). Lesser, but significant (P < 0.01) changes in serum alpha-tocopherol values were an approximate 10% decrease when refrigerated blood was left in contact with the red rubber stopper of the blood collection tube for 72 hours and an approximate 5% increase when blood was stored at 20 to 25 C (room temperature) for 72 hours. Repeated freeze/thaw cycles resulted in a significant (P < 0.05) 3% decrease in alpha-tocopherol values in heparinized plasma by the third thawing cycle. Freezer storage for a 3-month period without nitrogen blanketing resulted in slight (2%) decrease in mean serum alpha-tocopherol values, whereas values in serum stored for an identical period under nitrogen blanketing did not change. A significant (P < 0.001) mean decrease (10.3%) in alpha-tocopherol values was associated with freezer (-16 C) storage of nitrogen blanketed serum for 6 months.(ABSTRACT TRUNCATED AT 250 WORDS)
Jaiswal, Roshni; Shenoy, Nina; Thomas, Biju
2016-01-01
Stress classically describes a destructive notion that can have a bearing on one's physical and mental health. It may also add to an increased propensity to periodontal disease. To investigate the association between psychological stress and serum cortisol levels in patients with chronic periodontitis. Forty subjects were recruited from the outpatient department at the Department of Periodontics, from a college in Mangalore, divided into two groups, i.e., twenty as healthy controls and twenty were stressed subjects with chronic periodontitis. The clinical examination included the assessment of probing pocket depth, clinical attachment level and oral hygiene index-simplified. Serum cortisol levels were estimated biochemically using the enzyme-linked immunosorbent assay method and the estimation of psychological stress was done by a questionnaire. Descriptive statistics such as mean and standard deviation was used to review the collected data. Independent sample t -test was used for comparison and correlation was evaluation using Pearson's correlation test. As per our observation, high serum cortisol levels and psychological stress are positively linked with chronic periodontitis establishing a risk profile showing a significant correlation ( P < 0.05). Routine serum cortisol assessment may be a reasonable and a valuable investigative indicator to rule out stress in periodontitis patients as it should be considered as an imperative risk factor for periodontal disease.
Jaiswal, Roshni; Shenoy, Nina; Thomas, Biju
2016-01-01
Background: Stress classically describes a destructive notion that can have a bearing on one's physical and mental health. It may also add to an increased propensity to periodontal disease. Aim: To investigate the association between psychological stress and serum cortisol levels in patients with chronic periodontitis. Materials and Methods: Forty subjects were recruited from the outpatient department at the Department of Periodontics, from a college in Mangalore, divided into two groups, i.e., twenty as healthy controls and twenty were stressed subjects with chronic periodontitis. The clinical examination included the assessment of probing pocket depth, clinical attachment level and oral hygiene index-simplified. Serum cortisol levels were estimated biochemically using the enzyme-linked immunosorbent assay method and the estimation of psychological stress was done by a questionnaire. Results: Descriptive statistics such as mean and standard deviation was used to review the collected data. Independent sample t-test was used for comparison and correlation was evaluation using Pearson's correlation test. As per our observation, high serum cortisol levels and psychological stress are positively linked with chronic periodontitis establishing a risk profile showing a significant correlation (P < 0.05). Conclusion: Routine serum cortisol assessment may be a reasonable and a valuable investigative indicator to rule out stress in periodontitis patients as it should be considered as an imperative risk factor for periodontal disease. PMID:28298818
Pedrotti Moreira, Fernanda; Wiener, Carolina David; Jansen, Karen; Portela, Luis Valmor; Lara, Diogo R; Souza, Luciano Dias de Mattos; da Silva, Ricardo Azevedo; Oses, Jean Pierre
2018-06-15
The aim of this study was to evaluate the effect of childhood trauma in cytokine serum levels of individuals with MDD. This was a cross-sectional study population-based, with people aged 18 to 35. The Mini International Neuropsychiatric Interview (M.I.N.I) measured to current major depressive disorder (MDD). To evaluate traumatic experiences during childhood, the Childhood Trauma Questionnaire (CTQ) was applied. Serum TNF- α, IL-6 and IL-10 levels were measured by ELISA using a commercial kit. The total sample comprised 166 young adults, of these: 40.4% were subjects with MDD and childhood trauma and 59.6% were diagnosed with MDD without childhood trauma. In relation to serum interleukin levels, subjects with childhood trauma showed a significantly higher serum IL-6 (p = 0.013) and IL-10 levels (p = 0.022) to compare no childhood trauma. Subjects with childhood trauma was observed positive correlation between serum IL-6 and physical abuse (r = 0.232, p = 0.035) and emotional abuse (r = 0.460, p ≤ 0.001). Moreover, IL-10 were positive correlation with physical abuse (r = 0.258, p = 0.013). TNF- α was not associated with childhood trauma. Childhood maltreatment may result higher inflammation dysregulation in individuals with depression than individuals that no has childhood maltreatment. Copyright © 2018 Elsevier B.V. All rights reserved.
High serum total cholesterol is a long-term cause of osteoporotic fracture.
Trimpou, P; Odén, A; Simonsson, T; Wilhelmsen, L; Landin-Wilhelmsen, K
2011-05-01
Risk factors for osteoporotic fractures were evaluated in 1,396 men and women for a period of 20 years. Serum total cholesterol was found to be an independent osteoporotic fracture risk factor whose predictive power improves with time. The purpose of this study was to evaluate long-term risk factors for osteoporotic fracture. A population random sample of men and women aged 25-64 years (the Gothenburg WHO MONICA project, N = 1,396, 53% women) was studied prospectively. The 1985 baseline examination recorded physical activity at work and during leisure time, psychological stress, smoking habits, coffee consumption, BMI, waist/hip ratio, blood pressure, total, HDL and LDL cholesterol, triglycerides, and fibrinogen. Osteoporotic fractures over a period of 20 years were retrieved from the Gothenburg hospital registers. Poisson regression was used to analyze the predictive power for osteoporotic fracture of each risk factor. A total number of 258 osteoporotic fractures occurred in 143 participants (10.2%). As expected, we found that previous fracture, smoking, coffee consumption, and lower BMI each increase the risk for osteoporotic fracture independently of age and sex. More unexpectedly, we found that the gradient of risk of serum total cholesterol to predict osteoporotic fracture significantly increases over time (p = 0.0377). Serum total cholesterol is an independent osteoporotic fracture risk factor whose predictive power improves with time. High serum total cholesterol is a long-term cause of osteoporotic fracture.
Serum Autoantibodies in Chronic Prostate Inflammation in Prostate Cancer Patients.
Schlick, Bettina; Massoner, Petra; Lueking, Angelika; Charoentong, Pornpimol; Blattner, Mirjam; Schaefer, Georg; Marquart, Klaus; Theek, Carmen; Amersdorfer, Peter; Zielinski, Dirk; Kirchner, Matthias; Trajanoski, Zlatko; Rubin, Mark A; Müllner, Stefan; Schulz-Knappe, Peter; Klocker, Helmut
2016-01-01
Chronic inflammation is frequently observed on histological analysis of malignant and non-malignant prostate specimens. It is a suspected supporting factor for prostate diseases and their progression and a main cause of false positive PSA tests in cancer screening. We hypothesized that inflammation induces autoantibodies, which may be useful biomarkers. We aimed to identify and validate prostate inflammation associated serum autoantibodies in prostate cancer patients and evaluate the expression of corresponding autoantigens. Radical prostatectomy specimens of prostate cancer patients (N = 70) were classified into high and low inflammation groups according to the amount of tissue infiltrating lymphocytes. The corresponding pre-surgery blood serum samples were scrutinized for autoantibodies using a low-density protein array. Selected autoantigens were identified in prostate tissue and their expression pattern analyzed by immunohistochemistry and qPCR. The identified autoantibody profile was cross-checked in an independent sample set (N = 63) using the Luminex-bead protein array technology. Protein array screening identified 165 autoantibodies differentially abundant in the serum of high compared to low inflammation patients. The expression pattern of three corresponding antigens were established in benign and cancer tissue by immunohistochemistry and qPCR: SPAST (Spastin), STX18 (Syntaxin 18) and SPOP (speckle-type POZ protein). Of these, SPAST was significantly increased in prostate tissue with high inflammation. All three autoantigens were differentially expressed in primary and/or castration resistant prostate tumors when analyzed in an inflammation-independent tissue microarray. Cross-validation of the inflammation autoantibody profile on an independent sample set using a Luminex-bead protein array, retrieved 51 of the significantly discriminating autoantibodies. Three autoantibodies were significantly upregulated in both screens, MUT, RAB11B and CSRP2 (p>0.05), two, SPOP and ZNF671, close to statistical significance (p = 0.051 and 0.076). We provide evidence of an inflammation-specific autoantibody profile and confirm the expression of corresponding autoantigens in prostate tissue. This supports evaluation of autoantibodies as non-invasive markers for prostate inflammation.
Serum Autoantibodies in Chronic Prostate Inflammation in Prostate Cancer Patients
Schlick, Bettina; Massoner, Petra; Lueking, Angelika; Charoentong, Pornpimol; Blattner, Mirjam; Schaefer, Georg; Marquart, Klaus; Theek, Carmen; Amersdorfer, Peter; Zielinski, Dirk; Kirchner, Matthias; Trajanoski, Zlatko; Rubin, Mark A.; Müllner, Stefan; Schulz-Knappe, Peter; Klocker, Helmut
2016-01-01
Background Chronic inflammation is frequently observed on histological analysis of malignant and non-malignant prostate specimens. It is a suspected supporting factor for prostate diseases and their progression and a main cause of false positive PSA tests in cancer screening. We hypothesized that inflammation induces autoantibodies, which may be useful biomarkers. We aimed to identify and validate prostate inflammation associated serum autoantibodies in prostate cancer patients and evaluate the expression of corresponding autoantigens. Methods Radical prostatectomy specimens of prostate cancer patients (N = 70) were classified into high and low inflammation groups according to the amount of tissue infiltrating lymphocytes. The corresponding pre-surgery blood serum samples were scrutinized for autoantibodies using a low-density protein array. Selected autoantigens were identified in prostate tissue and their expression pattern analyzed by immunohistochemistry and qPCR. The identified autoantibody profile was cross-checked in an independent sample set (N = 63) using the Luminex-bead protein array technology. Results Protein array screening identified 165 autoantibodies differentially abundant in the serum of high compared to low inflammation patients. The expression pattern of three corresponding antigens were established in benign and cancer tissue by immunohistochemistry and qPCR: SPAST (Spastin), STX18 (Syntaxin 18) and SPOP (speckle-type POZ protein). Of these, SPAST was significantly increased in prostate tissue with high inflammation. All three autoantigens were differentially expressed in primary and/or castration resistant prostate tumors when analyzed in an inflammation-independent tissue microarray. Cross-validation of the inflammation autoantibody profile on an independent sample set using a Luminex-bead protein array, retrieved 51 of the significantly discriminating autoantibodies. Three autoantibodies were significantly upregulated in both screens, MUT, RAB11B and CSRP2 (p>0.05), two, SPOP and ZNF671, close to statistical significance (p = 0.051 and 0.076). Conclusions We provide evidence of an inflammation-specific autoantibody profile and confirm the expression of corresponding autoantigens in prostate tissue. This supports evaluation of autoantibodies as non-invasive markers for prostate inflammation. PMID:26863016
Kataoka, H; Narimatsu, S; Lord, H L; Pawliszyn, J
1999-10-01
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. LC/MS analyses of beta-blockers were initially performed by liquid injection onto a LC column. Nine beta-blockers tested in this study gave very simple ESI mass spectra, and strong signals corresponding to [M + H]+ were observed for all beta-blockers. The beta-blockers were separated with a Hypersil BDS C18 column using acetonitrile/methanol/water/acetic acid (15:15:70:1) as a mobile phase. To optimize the extraction of beta-blockers, several in-tube SPME parameters were examined. The optimum extraction conditions were 15 draw/eject cycles of 30 microL of sample in 100 mM Tris-HCl (pH 8.5) at a flow rate of 100 microL/min using an Omegawax 250 capillary (Supelco, Bellefonte, PA). The beta-blockers extracted by the capillary were easily desorbed by mobile-phase flow, and carryover of beta-blockers was not observed. Using in-tube SPME/LC/ESI-MS with selected ion monitoring, the calibration curves of beta-blockers were linear in the range from 2 to 100 ng/mL with correlation coefficients above 0.9982 (n = 18) and detection limits (S/N = 3) of 0.1-1.2 ng/mL. This method was successfully applied to the analysis of biological samples without interference peaks. The recoveries of beta-blockers spiked into human urine and serum samples were above 84 and 71%, respectively. A serum sample from a patient administrated propranolol was analyzed using this method and both propranolol and its metabolites were detected.
Murata, Kenji; Kanno, Shunsuke; Nishio, Hisanori; Saito, Mitsumasa; Tanaka, Tamami; Yamamura, Kenichiro; Sakai, Yasunari; Takada, Hidetoshi; Miyamoto, Tomofumi; Mizuno, Yumi; Ouchi, Kazunobu; Waki, Kenji; Hara, Toshiro
2014-01-01
Background Kawasaki disease (KD) is a systemic vasculitis of unknown etiology. The innate immune system is involved in its pathophysiology at the acute phase. We have recently established a novel murine model of KD coronary arteritis by oral administration of a synthetic microbe-associated molecular pattern (MAMP). On the hypothesis that specific MAMPs exist in KD sera, we have searched them to identify KD-specific molecules and to assess the pathogenesis. Methods We performed liquid chromatography-mass spectrometry (LC-MS) analysis of fractionated serum samples from 117 patients with KD and 106 controls. Microbiological and LC-MS evaluation of biofilm samples were also performed. Results KD samples elicited proinflammatory cytokine responses from human coronary artery endothelial cells (HCAECs). By LC-MS analysis of KD serum samples collected at 3 different periods, we detected a variety of KD-specific molecules in the lipophilic fractions that showed distinct m/z and MS/MS fragmentation patterns in each cluster. Serum KD-specific molecules showed m/z and MS/MS fragmentation patterns almost identical to those of MAMPs obtained from the biofilms formed in vitro (common MAMPs from Bacillus cereus, Yersinia pseudotuberculosis and Staphylococcus aureus) at the 1st study period, and from the biofilms formed in vivo (common MAMPs from Bacillus cereus, Bacillus subtilis/Bacillus cereus/Yersinia pseudotuberculosis and Staphylococcus aureus) at the 2nd and 3rd periods. The biofilm extracts from Bacillus cereus, Bacillus subtilis, Yersinia pseudotuberculosis and Staphylococcus aureus also induced proinflammatory cytokines by HCAECs. By the experiments with IgG affinity chromatography, some of these serum KD-specific molecules bound to IgG. Conclusions We herein conclude that serum KD-specific molecules were mostly derived from biofilms and possessed molecular structures common to MAMPs from Bacillus cereus, Bacillus subtilis, Yersinia pseudotuberculosis and Staphylococcus aureus. Discovery of these KD-specific molecules might offer novel insight into the diagnosis and management of KD as well as its pathogenesis. PMID:25411968
Altermann, Wolfgang; Schlaf, Gerald; Rothhoff, Anita; Seliger, Barbara
2007-10-01
Previous studies have suggested that the pre-transplant levels of the soluble CD30 molecule (sCD30) represent a non-invasive tool which can be used as a biomarker for the prediction of kidney allograft rejections. In order to evaluate the feasibility of sCD30 for pre-transplantation monitoring the sera of potential kidney recipients (n = 652) were collected four times in a 3 months interval. Serum from healthy blood donors (n = 203) served as controls. The sCD30 concentrations of all samples were determined using a commercially available ELISA. This strategy allowed the detection of possible variations of individual sCD30 levels over time. Heterogeneous sCD30 concentrations were found in the samples obtained from individual putative kidney transplant recipients when quarterly measured over 1 year. Total 95% of serum samples obtained from healthy controls exhibited sCD30 values <30 U/ml, whereas most recipients displayed higher serum levels (>30 U/ml). Total 524 patients (80.4%) constantly exhibited serum concentrations of <100 U/ml during the period investigated, whereas 109 patients (16.7%) showed variations by exceeding the proposed 'cut off' of 100 U/ml for one to three times. The frequency of samples exhibiting sCD30 values >100 U/ml was significantly lower than that previously reported. The high degree of variation does not allow the stratification of patients into high and low immunological risk groups based on a single sCD30 value > 100 U/ml. Due to the heterogeneity of sCD30 levels during time course and the high values of SD, its implementation as a pre-transplant marker cannot be justified to generate special provisions for the organ allocation to patients with single sCD30 values > 100 U/ml.
Measurement of rivaroxaban and apixaban in serum samples of patients
Harenberg, Job; Krämer, Sandra; Du, Shanshan; Zolfaghari, Shabnam; Schulze, Astrid; Krämer, Roland; Weiss, Christel; Wehling, Martin; Lip, Gregory Y H
2014-01-01
Background The determination of rivaroxaban and apixaban from serum samples of patients may be beneficial in specific clinical situations when additional blood sampling for plasma and thus the determination of factor Xa activity is not feasible or results are not plausible. Materials and methods The primary aim of this study was to compare the concentrations of rivaroxaban and apixaban in serum with those measured in plasma. Secondary aims were the performance of three different chromogenic methods and concentrations in patients on treatment with rivaroxaban 10 mg od (n = 124) or 20 mg od (n = 94) or apixaban 5 mg bid (n = 52) measured at different time. Results Concentrations of rivaroxaban and apixaban in serum were about 20–25% higher compared with plasma samples with a high correlation (r = 0·79775–0·94662) using all assays (all P < 0·0001). The intraclass correlation coefficients were about 0·90 for rivaroxaban and 0·55 for apixaban. Mean rivaroxaban concentrations were higher at 2 and 3 h compared with 1 and 12 h after administration measured from plasma and serum samples (all P-values < 0·05) and were not different between 1 vs. 12 h (plasma and serum). Conclusions The results indicate that rivaroxaban and apixaban concentrations can be determined specifically from serum samples. PMID:24931429
Heilmann, Romy M; Otoni, Cristiane C; Jergens, Albert E; Grützner, Niels; Suchodolski, Jan S; Steiner, Jörg M
2014-10-15
Inflammatory bowel disease (IBD) is a common condition in dogs, and a dysregulated innate immunity is believed to play a major role in its pathogenesis. S100A12 is an endogenous damage-associated molecular pattern molecule, which is involved in phagocyte activation and is increased in serum/fecal samples from dogs with IBD. S100A12 binds to the receptor of advanced glycation end products (RAGE), a pattern-recognition receptor, and results of studies in human patients with IBD and other conditions suggest a role of RAGE in chronic inflammation. Soluble RAGE (sRAGE), a decoy receptor for inflammatory proteins (e.g., S100A12) that appears to function as an anti-inflammatory molecule, was shown to be decreased in human IBD patients. This study aimed to evaluate serum sRAGE and serum/fecal S100A12 concentrations in dogs with IBD. Serum and fecal samples were collected from 20 dogs with IBD before and after initiation of medical treatment and from 15 healthy control dogs. Serum sRAGE and serum and fecal S100A12 concentrations were measured by ELISA, and were compared between dogs with IBD and healthy controls, and between dogs with a positive outcome (i.e., clinical remission, n=13) and those that were euthanized (n=6). The relationship of serum sRAGE concentrations with clinical disease activity (using the CIBDAI scoring system), serum and fecal S100A12 concentrations, and histologic disease severity (using a 4-point semi-quantitative grading system) was tested. Serum sRAGE concentrations were significantly lower in dogs with IBD than in healthy controls (p=0.0003), but were not correlated with the severity of histologic lesions (p=0.4241), the CIBDAI score before (p=0.0967) or after treatment (p=0.1067), the serum S100A12 concentration before (p=0.9214) and after treatment (p=0.4411), or with the individual outcome (p=0.4066). Clinical remission and the change in serum sRAGE concentration after treatment were not significantly associated (p=0.5727); however, serum sRAGE concentrations increased only in IBD dogs with complete clinical remission. Also, dogs that were euthanized had significantly higher fecal S100A12 concentrations than dogs that were alive at the end of the study (p=0.0124). This study showed that serum sRAGE concentrations are decreased in dogs diagnosed with IBD compared to healthy dogs, suggesting that sRAGE/RAGE may be involved in the pathogenesis of canine IBD. Lack of correlation between sRAGE and S100A12 concentrations is consistent with sRAGE functioning as a non-specific decoy receptor. Further studies need to evaluate the gastrointestinal mucosal expression of RAGE in healthy and diseased dogs, and also the formation of S100A12-RAGE complexes. Copyright © 2014 Elsevier B.V. All rights reserved.
Iwersen, M; Klein-Jöbstl, D; Pichler, M; Roland, L; Fidlschuster, B; Schwendenwein, I; Drillich, M
2013-01-01
The objective of this study was to determine the suitability of 2 electronic hand-held devices [FreeStyle Precision (FSP), Abbott GmbH & Co. KG, Wiesbaden, Germany and GlucoMen LX Plus (GLX), A. Menarini GmbH, Vienna, Austria] for measuring β-hydroxybutyrate (BHBA) in dairy cows. Three experiments were conducted to evaluate (1) the diagnostic performance of the devices, (2) the effect of the type of blood sample, and (3) the influence of the ambient temperature on the determined results. A total of 415 blood samples from lactating Holstein and Simmental cows were collected and analyzed with both devices (whole blood) and in a laboratory (serum). Correlation coefficients between whole-blood and serum BHBA concentrations were highly significant, with 94% for the FSP and 80% for the GLX device. Based on thresholds for subclinical ketosis of 1.2 and 1.4 mmol of BHBA/L, results obtained with the hand-held devices were evaluated by receiver operating characteristics analyses. This resulted in adjusted thresholds of 1.2 and 1.4 mmol/L for the FSP and 1.1 and 1.3 mmol/L for the GLX device. Applying these thresholds, sensitivities were 98 and 100% for the FSP and 80 and 86% for the GLX device, respectively. Corresponding specificities were 90 and 97% for the FSP and 87 and 96% for the GLX device, respectively. Additionally, concentrations of BHBA were tested with both devices in whole blood, EDTA-added whole blood, and in their resulting serum and plasma, collected from 65 animals. Determined BHBA concentrations were similar within each device for whole and EDTA-added blood, and in serum and plasma, but differed between whole blood and serum and between EDTA-added blood and plasma. Blood samples with low (0.4 mmol/L), medium (1.1 mmol/L), and high (1.6 mmol/L) BHBA concentrations were stored between +5 to +32°C and analyzed repeatedly at temperature levels differing by 4°C. Additionally, devices and test strips were stored at equal conditions and used for measurement procedures. Storage temperature of the devices and test strips did not influence the differences between the results of the laboratory and the devices, whereas the temperature of the blood samples caused significant differences. Although the level of agreement between the laboratory and the GLX device was lower than for the laboratory and the FSP device, both devices are useful tools for monitoring subclinical ketosis in dairy cows. Due to their effects on the determined results, the type and temperature of the tested sample should be considered. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
2015-08-01
testing by virus isolation (VI). Positive-control mosquitoes were sampled whole on the day of the spiked blood meal. b NA, not applicable. Miller et al ...percent inhibition of the negative control, calculated as 1 (test serum OD/negative serum OD) 100. Miller et al . 934 cvi.asm.org August 2015 Volume 22...Trop Med Hyg 44:278 –282. 34. Morrill JC, Mebus CA, Peters CJ. 1997. Safety of a mutagen-attenuated Miller et al . 936 cvi.asm.org August 2015 Volume 22
Cells and biofluids analyzed in aqueous environment by infrared spectroscopy
NASA Astrophysics Data System (ADS)
Naumann, D.; Lasch, P.; Fabian, H.
2006-02-01
Infrared transmission/absorption measurements of cells and biofluids in water are restricted to very short optical pathlengths. When the amide I and amide II bands of protein constituents have to be analysed, path-lengths of less than 8 μm are necessary. Infrared spectra of cancer cells were collected from physiological buffer solutions utilizing custom-made mid-infrared compatible IR-cuvettes. The technology permitted to obtain cell-type specific spectral signatures and probe biochemical changes induced by varying temperatures or cell-drug interaction. Optical path-lengths of 8-30 μm were used on a set of microbial test strains to evaluate, whether the methodology can also be used to discriminate and identify micro-organisms. A semi-automatic methodology was developed for the analysis of liquid serum samples, which combines simple sample handling with high sample throughput and extreme measurement reproducibility. The applicability of this infrared technology to the analysis of liquid serum samples from cattle and human beings suffering from various acute viral or bacterial infections was explored testing the interrelationship between α-helical and β-sheet specific spectral signatures in the amide I band contour and total albumin and globulin content in serum. The technical details, advantages, and limitations of the new technology are described in the context of developing a routine, IR-based biodiagnostic technique for biofluids and biological cells.
Epidemiological study of pestiviruses in South American camelids in Switzerland.
Mudry, M; Meylan, M; Regula, G; Steiner, A; Zanoni, R; Zanolari, P
2010-01-01
In the context of the ongoing eradication campaign for bovine viral diarrhea virus (BVDV) in cattle in Switzerland, the role of South American camelids (SAC) as a possible virus reservoir needed to be evaluated. To assess and characterize the prevalence of pestivirus infections in SAC in Switzerland. Serum samples collected from 348 animals (40 herds) in 2008 and from 248 animals (39 herds) in 2000 were examined for antibodies against pestiviruses and for the presence of BVDV viral RNA. Cross-sectional study using stratified, representative herd sampling. An indirect BVDV-ELISA was used to analyze serum samples for pestivirus antibodies, and positive samples underwent a serum neutralization test (SNT). Real-time RT-PCR to detect pestiviral RNA was carried out in all animals from herds with at least 1 seropositive animal. In 2008, the overall prevalence of animals positive for antibodies (ELISA) and pestiviral RNA or was 5.75 and 0%, respectively. In 2000, the corresponding prevalences were 3.63 and 0%, respectively. The seroprevalences (SNT) for BVDV, border disease virus or undetermined pestiviruses were estimated to be 0, 1.73, and 4.02% in 2008, and 0.40, 1.21, and 2.02% in 2000, respectively. At the present time, SAC appear to represent a negligible risk of re-infection for the BVDV eradication program in cattle in Switzerland. Copyright © 2010 by the American College of Veterinary Internal Medicine.
Low Vitamin D Status and Suicide: A Case-Control Study of Active Duty Military Service Members
Umhau, John C.; George, David T.; Heaney, Robert P.; Lewis, Michael D.; Ursano, Robert J.; Heilig, Markus
2013-01-01
Objective Considering that epidemiological studies show that suicide rates in many countries are highest in the spring when vitamin D status is lowest, and that low vitamin D status can affect brain function, we sought to evaluate if a low level of 25-hydroxyvitamin D [25(OH)D] could be a predisposing factor for suicide. Method We conducted a prospective, nested, case-control study using serum samples stored in the Department of Defense Serum Repository. Participants were previously deployed active duty US military personnel (2002–2008) who had a recent archived serum sample available for analysis. Vitamin D status was estimated by measuring 25(OH) D levels in serum samples drawn within 24 months of the suicide. Each verified suicide case (n = 495) was matched to a control (n = 495) by rank, age and sex. We calculated odds ratio of suicide associated with categorical levels (octiles) of 25(OH) D, adjusted by season of serum collection. Findings More than 30% of all subjects had 25(OH)D values below 20 ng/mL. Although mean serum 25(OH)D concentrations did not differ between suicide cases and controls, risk estimates indicated that subjects in the lowest octile of season-adjusted 25(OH)D (<15.5 ng/mL) had the highest risk of suicide, with subjects in the subsequent higher octiles showing approximately the same level of decreased risk (combined odds ratio compared to lowest octile = 0.49; 95% C.I.: 0.315–0.768). Conclusions Low vitamin D status is common in active duty service members. The lowest 25(OH)D levels are associated with an increased risk for suicide. Future studies could determine if additional sunlight exposure and vitamin D supplementation might reduce suicide by increasing 25(OH) D levels. PMID:23308099
Shu, Irene; Wang, Ping
2013-06-01
Concentrations of nicotine and its metabolites in blood are indicative of patients' current tobacco exposure, and their quantifications have been clinically applied to multiple assessments including demonstration of abstinence prior to heart-lung transplantation. For the purpose of transplant evaluation, the laboratory work up is extensive; thereby an assay with minimal sample volume is preferred. We developed and validated a rapid LC-MS/MS assay to simultaneously quantitate nicotine and its major metabolites, Cotinine and trans-3'-OH-cotinine (3-OH-Cot), in serum. 100μL of serum was spiked with deuterated internal standards and extracted by Oasis HLB solid phase extraction cartridge. Nicotine and metabolites in the reconstituted serum extract were separated by Agilent Eclipse XDB-C8 3.5μm 2.1mm×50mm HPLC column within 4.7min, and quantified by MS/MS with positive mode electrospray ionization and multiple reaction monitoring. Ion suppression was insignificant, and extraction efficiency was 79-110% at 50ng/mL for all compounds. Limit of detection was 1.0ng/mL for nicotine and 3-OH-Cot, and <0.5ng/mL for Cotinine. Linearity ranges for nicotine, cotinine and 3-OH-Cot were 2-100, 2-1000, and 5-1000ng/mL with recoveries of 86-115%. Within-day and twenty-day imprecision at nicotine/cotinine/3-OH-Cot levels of 22/150/90, 37/250/150, and 50/800/500ng/mL were all 1.1-6.5%. The reconstituted serum extracts were stable for at least 7 days stored in the HPLC autosampler at 5°C. Our method correlates well with alternative LC-MS/MS methods. We successfully developed and validated an LC-MS/MS assay to quantitate concentrations of nicotine and its metabolites in serum with minimal sample volume to assess tobacco exposure of heart-lung transplant patients. Copyright © 2013 Elsevier B.V. All rights reserved.
Chen, Yang; Harrington, Brittney S; Lau, Kevin C N; Burke, Lez J; He, Yaowu; Iconomou, Mary; Palmer, James S; Meade, Brian; Lumley, John W; Hooper, John D
2017-05-30
CUB domain containing protein 1 (CDCP1) is a transmembrane protein involved in progression of several cancers. When located on the plasma membrane, full-length 135kDa CDCP1 can undergo proteolysis mediated by serine proteases that cleave after two adjacent amino acids (arginine 368 and lysine 369). This releases from the cell surface two 65kDa fragments, collectively termed ShE-CDCP1, that differ by one carboxyl terminal residue. To evaluate the function of CDCP1 and its potential utility as a cancer biomarker, in this study we developed an enzyme-linked immunosorbent assay (ELISA) to reliably and easily measure the concentration of ShE-CDCP1 in biological samples. Using a reference standard we demonstrate that the developed ELISA has a working range of 0.68-26.5ng/ml, and the limit of detection is 0.25ng/ml. It displays high intra-assay (repeatability) and high inter-assay (reproducibility) precision with all coefficients of variation ≤7%. The ELISA also displays high accuracy detecting ShE-CDCP1 levels at ≥94.8% of actual concentration using quality control samples. We employed the ELISA to measure the concentration of ShE-CDCP1 in human serum samples with our results suggesting that levels are significantly higher in serum of colorectal cancer patients compared with serum from individuals with benign conditions (p<0.05). Our data also suggest that colorectal cancer patients with stage II-IV disease have at least 50% higher serum levels of ShE-CDCP1 compared with stage I cases (p<0.05). We conclude that the developed ELISA is a suitable method to quantify ShE-CDCP1 concentration in human serum. Copyright © 2017 Elsevier B.V. All rights reserved.
A Turkish 3-center study evaluation of serum folic acid and vitamin B12 levels in Alzheimer disease.
Ulusu, Nuriye Nuray; Yilmaz, Gökhan; Erbayraktar, Zübeyde; Evlice, Ahmet Turan; Aras, Sevgi; Yener, Görsev; Avci, Aslihan
2015-01-01
Alzheimer disease, a common proteopathy of advanced age, is characterized by cortical atrophy, neuron degeneration, neuronal loss, and accumulation of extracellular amyloid β plaques. We aimed to investigate serum vitamin B12 and folic acid levels in Alzheimer disease and other dementia patients, as a potential screening test to detect presymptomatic Alzheimer disease in Turkish patients. We evaluated folic acid and vitamin B12 levels in Alzheimer disease patients as well as in other dementia and geriatric patients from Ankara, Dokuz Eylül, and Çukurova university hospitals; 290 female and male geriatric subjects were enrolled. Vitamin B12 and folic acid levels were measured using Roche E170 and Beckman Coulter DXI 800 immunoassays (chemiluminescence) according to the manufacturers' guideline in all centers. We evaluated the results of folic acid and vitamin B12 in Alzheimer disease, other dementias and geriatric patients. No significant difference between the groups regarding the routine control of biochemical parameters was observed. Currently, serum folic and vitamin B12 levels are not diagnostically reliable tests for screening presymptomatic Alzheimer disease. However, the results may statistically be significant if we increase the sample size.
Population pharmacokinetics of transdermal fentanyl in patients with cancer-related pain.
Kokubun, Hideya; Ebinuma, Keiichi; Matoba, Motohiro; Takayanagi, Risa; Yamada, Yasuhiko; Yago, Kazuo
2012-06-01
Determining the appropriate dose of transdermal fentanyl (TDF) for the alleviation of cancer pain requires determining the factors causing variations in serum fentanyl concentration after TDF treatment. The objective of this study was to identify these factors and incorporate them into a formula that can be used to predict serum fentanyl concentration after application of a TDF patch. Blood samples of cancer patients treated with a TDF patch for the alleviation of pain were collected at 24, 48, and 72 hours after application to evaluate population pharmacokinetics using the nonlinear mixed-effect model (NONMEM). Based upon this evaluation, Child-Pugh Score and use of a cytochrome P450 3A4 (CYP3A4) inducer were identified as the most significant factors in variations in serum fentanyl concentration and incorporated into the following Final Model formula: CL(fenta) (L/h) = 3.53 × (15 - Child-Pugh Score) × (1 + 1.38 × use or no use of CYP3A4 inducer). Bootstrap evaluation of the Final Model revealed a high convergence rate, suggesting that the model formula is a reliable and useful tool for determining TDF dose for the alleviation of cancer pain.
López Uriarte, Graciela Arelí; Burciaga Flores, Carlos Horacio; Torres de la Cruz, Víctor Manuel; Medina Aguado, María Magdalena; Gómez Puente, Viviana Maricela; Romero Gutiérrez, Liliana Nayeli; Martínez de Villarreal, Laura Elia
2018-06-01
Prenatal diagnosis of Down syndrome (DS) is based on the calculated risk of maternal age, biochemical and ultrasonographic markers and recently by cfDNA. Differences in proteomic profiles may give an opportunity to find new biomarkers. Characterize proteome of serum of mothers carrying DS fetus. Blood serum samples of three groups of women were obtained, (a) 10 non-pregnant, (b) 10 pregnant with healthy fetus by ultrasound evaluation, (c) nine pregnant with DS fetus. Sample preparation was as follows: Albumin/IgG depletion, desalting, and trypsin digestion; the process was performed in nanoUPLC MS/MS. Data analysis was made with Mass Lynx 4.1 and ProteinLynx Global Server 3.0, peptide and protein recognition by MASCOT algorithm and UNIPROT-Swissprot database. Each group showed different protein profiles. Some proteins were shared between groups. Only sera from pregnant women showed proteins related to immune and clot pathways. Mothers with DS fetus had 42 specific proteins. We found a different serum protein profile in mothers carrying DS fetuses that do not reflect expression of genes in the extra chromosome. Further studies will be necessary to establish the role of these proteins in aneuploid fetus and analyze their possible use as potential biomarkers.
YAMAMOTO, Kenya; KUDO, Mitsuhiro; ARITO, Heihachiro; OGAWA, Yasutaka; TAKATA, Tsutomu
2015-01-01
This cross-sectional study was intended to examine health effects of 678 male workers employed during an 8-yr period from 2000 to 2007 at 36 municipal and private waste incineration plants in Japan. Blood samples were obtained for analysis of concentrations of dioxins including coplanar polychlorinated biphenyls (coplanar PCBs) and evaluation of health effects. Health effects including diabetes were surveyed via a physician’s interview or clinical data from blood samples. There was a certain difference in serum concentrations of polychlorinated dibenzofurans (PCDFs) between the incinerator workers and Japanese general population, although no differences in the concentrations of total dioxins or polychlorinated dibenzo-p-dioxins (PCDDs) were found between the two groups. A few positive correlations between serum levels of PCDDs and PCDFs and the results of laboratory and physiological tests were found, but coplanar PCBs showed significant relations with 14 parameters of the tests. The background serum levels of PCDDs, PCDFs and total dioxins were significantly associated with the prevalence of diabetes. No essential differences in serum concentrations of total dioxins and in prevalence of diabetes between our subjects and the general population suggested that the incinerator workers were marginally exposed to dioxins in the workplace without any recognizable adverse health effects. PMID:26212412
Brain-Derived Neurotrophic Factor in Patients with Huntington's Disease
Zuccato, Chiara; Mariotti, Caterina; Valenza, Marta; Lahiri, Nayana; Wild, Edward J.; Sassone, Jenny; Ciammola, Andrea; Bachoud-Lèvi, Anne Catherine; Tabrizi, Sarah J.; Di Donato, Stefano; Cattaneo, Elena
2011-01-01
Reduced Brain-Derived Neurotrophic Factor (BDNF) levels have been described in a number of patho-physiological conditions, most notably, in Huntington's disease (HD), a progressive neurodegenerative disorder. Since BDNF is also produced in blood, we have undertaken the measurement of its peripheral levels in the attempt to identify a possible link with HD prognosis and/or its progression. Here we evaluated BDNF level in 398 blood samples including 138 controls, 56 preHD, and 204 HD subjects. We found that BDNF protein levels were not reliably different between groups, whether measured in plasma (52 controls, 26 preHD, 105 HD) or serum (39 controls, 5 preHD, 29 HD). Our experience, and a re-analysis of the literature highlighted that intra-group variability and methodological aspects affect this measurement, especially in serum. We also assessed BDNF mRNA levels in blood samples from 47 controls, 25 preHD, and 70 HD subjects, and found no differences among the groups. We concluded that levels of BDNF in human blood were not informative (mRNA levels or plasma protein level) nor reliable (serum protein levels) as HD biomarkers. We also wish to warn the scientific community in interpreting the significance of changes measured in BDNF protein levels in serum from patients suffering from different conditions. PMID:21857974
Austdal, Marie; Tangerås, Line H; Skråstad, Ragnhild B; Salvesen, Kjell; Austgulen, Rigmor; Iversen, Ann-Charlotte; Bathen, Tone F
2015-09-08
Hypertensive disorders of pregnancy, including preeclampsia, are major contributors to maternal morbidity. The goal of this study was to evaluate the potential of metabolomics to predict preeclampsia and gestational hypertension from urine and serum samples in early pregnancy, and elucidate the metabolic changes related to the diseases. Metabolic profiles were obtained by nuclear magnetic resonance spectroscopy of serum and urine samples from 599 women at medium to high risk of preeclampsia (nulliparous or previous preeclampsia/gestational hypertension). Preeclampsia developed in 26 (4.3%) and gestational hypertension in 21 (3.5%) women. Multivariate analyses of the metabolic profiles were performed to establish prediction models for the hypertensive disorders individually and combined. Urinary metabolomic profiles predicted preeclampsia and gestational hypertension at 51.3% and 40% sensitivity, respectively, at 10% false positive rate, with hippurate as the most important metabolite for the prediction. Serum metabolomic profiles predicted preeclampsia and gestational hypertension at 15% and 33% sensitivity, respectively, with increased lipid levels and an atherogenic lipid profile as most important for the prediction. Combining maternal characteristics with the urinary hippurate/creatinine level improved the prediction rates of preeclampsia in a logistic regression model. The study indicates a potential future role of clinical importance for metabolomic analysis of urine in prediction of preeclampsia.
Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro
2015-01-01
Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were <0.50 for 48% of amino acids, 27% of acylcarnitines, 18% of lysophosphatidylcholines and 4% of phosphatidylcholines. In non-fasting samples, the median ICC was 0.54. ICC values were <0.50 for 71% of acylcarnitines, 48% of amino acids, 44% of biogenic amines, 36% of sphingomyelins, 34% of phosphatidylcholines and 33% of lysophosphatidylcholines. Overall, reproducibility was lower in non-fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920
Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS
NASA Astrophysics Data System (ADS)
Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.
2013-09-01
Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.
Vera-Candioti, Luciana; Culzoni, María J; Olivieri, Alejandro C; Goicoechea, Héctor C
2008-11-01
Drug monitoring in serum samples was performed using second-order data generated by CE-DAD, processed with a suitable chemometric strategy. Carbamazepine could be accurately quantitated in the presence of its main metabolite (carbamazepine epoxide), other therapeutic drugs (lamotrigine, phenobarbital, phenytoin, phenylephrine, ibuprofen, acetaminophen, theophylline, caffeine, acetyl salicylic acid), and additional serum endogenous components. The analytical strategy consisted of the following steps: (i) serum sample clean-up to remove matrix interferences, (ii) data pre-processing, in order to reduce the background and to correct for electrophoretic time shifts, and (iii) resolution of fully overlapped CE peaks (corresponding to carbamazepine, its metabolite, lamotrigine and unexpected serum components) by the well-known multivariate curve resolution-alternating least squares algorithm, which extracts quantitative information that can be uniquely ascribed to the analyte of interest. The analyte concentration in serum samples ranged from 2.00 to 8.00 mg/L. Mean recoveries were 102.6% (s=7.7) for binary samples, and 94.8% (s=13.5) for spiked serum samples, while CV (%)=4.0 was computed for five replicate, indicative of the acceptable accuracy and precision of the proposed method.
Zahraei, Bentolhoda; Hashemzadeh, Mohammad Sadegh; Najarasl, Mohammad; Zahiriyeganeh, Samaneh; Tat, Mahdi; Metanat, Maliheh; Sepehri Rad, Nahid; Khansari-Nejad, Behzad; Zafari, Ehsan; Sharti, Mojtaba; Dorostkar, Ruhollah
2016-01-01
The Crimean-Congo hemorrhagic fever (CCHF) virus causes severe disease in humans, with a high mortality rate. Since, there is no approved vaccine or specific treatment for CCHF, an early and accurate diagnosis, as well as reliable surveillance, is essential for case management and patient improvement. For this research, our aim was to evaluate the application of a novel SYBR Green based one-step real-time reverse-transcriptase polymerase chain reaction (rRT-PCR) assay for the in-house diagnosis of the CCHF virus. In this experimental study, the highly conserved S-region sequence of the CCHF viral genome was first adapted from GenBank, and the specific primers targeting this region were designed. Then, the viral RNA was extracted from 75 serum samples from different patients in eastern Iran. The sensitivity and specificity of the primers were also evaluated in positive serum samples previously confirmed to have the CCHF virus, by this one-step rRT-PCR assay, as well as a DNA sequencing analysis. From a total of 75 suspected serum samples, 42 were confirmed to be positive for CCHF virus, with no false-positives detected by the sequencing results. After 40 amplification cycles, the melting curve analysis revealed a mean melting temperature (Tm) of 86.5 ± 0.6°C (quite different from those of the primer-dimers), and the positive samples showed only a small variation in the parameters. In all of the positive samples, the predicted length of 420 bp was confirmed by electrophoresis. Moreover, the sensitivity test showed that this assay can detect less than 20 copies of viral RNA per reaction. This study showed that this novel one-step rRT-PCR assay is a rapid, reliable, repeatable, specific, sensitive, and simple tool for the detection of the CCHF virus.
Reticulocyte hemoglobin equivalent as a potential marker for diagnosis of iron deficiency.
Toki, Yasumichi; Ikuta, Katsuya; Kawahara, Yoshie; Niizeki, Noriyasu; Kon, Masayuki; Enomoto, Motoki; Tada, Yuko; Hatayama, Mayumi; Yamamoto, Masayo; Ito, Satoshi; Shindo, Motohiro; Kikuchi, Yoko; Inoue, Mitsutaka; Sato, Kazuya; Fujiya, Mikihiro; Okumura, Toshikatsu
2017-07-01
Evaluation of parameters relating to serum ferritin and iron is critically important in the diagnosis of iron deficiency anemia (IDA). The recent development of automated systems for hematology analysis has made it possible to measure reticulocyte hemoglobin equivalent (RET-He), which is thought to reflect iron content in reticulocytes, in the same sample used for complete blood count tests. If RET-He is, indeed, capable of evaluating iron deficiency (ID), it would be useful for immediate diagnosis of IDA. In the present study, we examined the usefulness of RET-He for diagnosis of ID. Blood samples were obtained from 211 patients. Anemia was defined as hemoglobin (Hb) level of <12 g/dL. Iron deficiency was defined as serum ferritin level of <12 ng/mL. Patients were classified into four groups: IDA, ID, control, and non-ID with anemia. Patients in the IDA group had significantly lower RET-He levels than those in the control group. RET-He correlated with serum ferritin in the IDA and ID groups. The area under the curve for RET-He was 0.902, indicating that RET-He facilitates the diagnosis of ID with high accuracy. RET-He changed in parallel with changes in Hb during iron administration for 21 IDA patients. Our results indicate that RET-He may be a clinically useful marker for determining ID in the general population.
Liu, Ken H; Walker, Douglas I; Uppal, Karan; Tran, ViLinh; Rohrbeck, Patricia; Mallon, Timothy M; Jones, Dean P
2016-08-01
The aim of this study was to maximize detection of serum metabolites with high-resolution metabolomics (HRM). Department of Defense Serum Repository (DoDSR) samples were analyzed using ultrahigh resolution mass spectrometry with three complementary chromatographic phases and four ionization modes. Chemical coverage was evaluated by number of ions detected and accurate mass matches to a human metabolomics database. Individual HRM platforms provided accurate mass matches for up to 58% of the KEGG metabolite database. Combining two analytical methods increased matches to 72% and included metabolites in most major human metabolic pathways and chemical classes. Detection and feature quality varied by analytical configuration. Dual chromatography HRM with positive and negative electrospray ionization provides an effective generalized method for metabolic assessment of military personnel.
Liu, Ken H.; Walker, Douglas I.; Uppal, Karan; Tran, ViLinh; Rohrbeck, Patricia; Mallon, Timothy M.; Jones, Dean P.
2016-01-01
Objective To maximize detection of serum metabolites with high-resolution metabolomics (HRM). Methods Department of Defense Serum Repository (DoDSR) samples were analyzed using ultra-high resolution mass spectrometry with three complementary chromatographic phases and four ionization modes. Chemical coverage was evaluated by number of ions detected and accurate mass matches to a human metabolomics database. Results Individual HRM platforms provided accurate mass matches for up to 58% of the KEGG metabolite database. Combining two analytical methods increased matches to 72%, and included metabolites in most major human metabolic pathways and chemical classes. Detection and feature quality varied by analytical configuration. Conclusions Dual chromatography HRM with positive and negative electrospray ionization provides an effective generalized method for metabolic assessment of military personnel. PMID:27501105
Serological evidence for the presence of influenza D virus in small ruminants.
Quast, Megan; Sreenivasan, Chithra; Sexton, Gabriel; Nedland, Hunter; Singrey, Aaron; Fawcett, Linda; Miller, Grant; Lauer, Dale; Voss, Shauna; Pollock, Stacy; Cunha, Cristina W; Christopher-Hennings, Jane; Nelson, Eric; Li, Feng
2015-11-18
Influenza D virus (FLUDV) was isolated from diseased pigs with respiratory disease symptoms in 2011, and since then the new virus has also been spread to cattle. Little is known about the susceptibility of other agricultural animals and poultry to FLUDV. This study was designed to determine if other farm animals such as goats, sheep, chickens, and turkey are possible hosts to this newly emerging influenza virus. 648 goat and sheep serum samples and 250 chicken and turkey serum samples were collected from 141 small ruminant and 25 poultry farms from different geographical locations in the United States and Canada. Serum samples were examined using the hemagglutination inhibition (HI) assay and the sheep and goat samples were further analyzed using the serum neutralization assay. Results of this study showed FLUDV antibodies were detected in 13.5% (17/126) of the sampled sheep farms, and 5.2% (29/557) of tested sheep serum samples were positive for FLUDV antibodies. For the goat results, the FLUDV antibodies were detected in 13.3% (2/15) of the sampled farms, and 8.8% (8/91) of the tested goat serum samples were positive for FLUDV antibodies. Furthermore, all tested poultry serum samples were negative for FLUDV antibodies. Our data demonstrated that sheep and goat are susceptible to FLUDV virus and multiple states in U.S. have this virus infection already in these two species. This new finding highlights a need for future surveillance of FLUDV virus in small ruminants toward better understanding both the origin and natural reservoir of this new virus. Copyright © 2015 Elsevier B.V. All rights reserved.
Pietrowska, M; Marczak, L; Polanska, J; Nowicka, E; Behrent, K; Tarnawski, R; Stobiecki, M; Polanski, A; Widlak, P
2010-01-01
Mass spectrometry-based analysis of the serum proteome allows identifying multi-peptide patterns/signatures specific for blood of cancer patients, thus having high potential value for cancer diagnostics. However, because of problems with optimization and standardization of experimental and computational design, none of identified proteome patterns/signatures was approved for diagnostics in clinical practice as yet. Here we compared two methods of serum sample preparation for mass spectrometry-based proteome pattern analysis aimed to identify biomarkers that could be used in early detection of breast cancer patients. Blood samples were collected in a group of 92 patients diagnosed at early (I and II) stages of the disease before the start of therapy, and in a group of age-matched healthy controls (104 women). Serum specimens were purified and analyzed using MALDI-ToF spectrometry, either directly or after membrane filtration (50 kDa cut-off) to remove albumin and other large serum proteins. Mass spectra of the low-molecular-weight fraction (2-10 kDa) of the serum proteome were resolved using the Gaussian mixture decomposition, and identified spectral components were used to build classifiers that differentiated samples from breast cancer patients and healthy persons. Mass spectra of complete serum and membrane-filtered albumin-depleted samples have apparently different structure and peaks specific for both types of samples could be identified. The optimal classifier built for the complete serum specimens consisted of 8 spectral components, and had 81% specificity and 72% sensitivity, while that built for the membrane-filtered samples consisted of 4 components, and had 80% specificity and 81% sensitivity. We concluded that pre-processing of samples to remove albumin might be recommended before MALDI-ToF mass spectrometric analysis of the low-molecular-weight components of human serum Keywords: albumin removal; breast cancer; clinical proteomics; mass spectrometry; pattern analysis; serum proteome.
Jacobs, Peter L; Ridder, Lars; Ruijken, Marco; Rosing, Hilde; Jager, Nynke Gl; Beijnen, Jos H; Bas, Richard R; van Dongen, William D
2013-09-01
Comprehensive identification of human drug metabolites in first-in-man studies is crucial to avoid delays in later stages of drug development. We developed an efficient workflow for systematic identification of human metabolites in plasma or serum that combines metabolite prediction, high-resolution accurate mass LC-MS and MS vendor independent data processing. Retrospective evaluation of predictions for 14 (14)C-ADME studies published in the period 2007-January 2012 indicates that on average 90% of the major metabolites in human plasma can be identified by searching for accurate masses of predicted metabolites. Furthermore, the workflow can identify unexpected metabolites in the same processing run, by differential analysis of samples of drug-dosed subjects and (placebo-dosed, pre-dose or otherwise blank) control samples. To demonstrate the utility of the workflow we applied it to identify tamoxifen metabolites in serum of a breast cancer patient treated with tamoxifen. Previously published metabolites were confirmed in this study and additional metabolites were identified, two of which are discussed to illustrate the advantages of the workflow.
Sorge, U S; Molitor, T; Linn, J; Gallaher, D; Wells, S W
2013-02-01
Vitamin D deficiency has been associated with various human diseases. Therefore, the objective of this study was to evaluate the cow-level association between serum 25-hydroxyvitamin D [25(OH)D] concentration and Mycobacterium avium ssp. paratuberculosis (MAP) seropositivity of dairy cows, adjusting for diet, breed, hair coat color, stage of lactation, reproductive status, and cow age. The sera of 80 MAP antibody ELISA-positive and 80 test-negative herd mates from 5 Minnesota dairy herds were analyzed for 25(OH)D and 1,25-dihydroxyvitamin D [1,25(OH)(2)D]. The cows' age, production records, and hair coat color were recorded. Additionally, feed samples were obtained and analyzed for vitamin D(2) and vitamin D(3) content. A linear mixed model was used to identify potential predictors for serum 25(OH)D concentration, accounting for herd of origin. The majority of rations analyzed had over 22,000 IU of vitamin D/day (maximum: 52,000 I U/d) and the study cows' average serum 25(OH)D concentration was 62.5 ± 13.8 ng/mL. Serum ELISA-positive cows had, on average, 5.3 ng/mL lower 25(OH)D serum levels than test-negative herd mates. The reproductive status of cows was also associated with the 25(OH)D levels, with fresh cows having the lowest serum concentration. In this cross-sectional study, a temporal or causal association between MAP antibody ELISA status and serum 25(OH)D concentration could not be evaluated. In addition, the high levels of vitamin D in the rations of participating farms and the average 25(OH)D serum concentration suggest that additional supplementation with vitamin D in the ration is likely to be ineffective. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Comparison of oral fluid collection methods for the molecular detection of hepatitis B virus.
Portilho, M M; Mendonça, Acf; Marques, V A; Nabuco, L C; Villela-Nogueira, C A; Ivantes, Cap; Lewis-Ximenez, L L; Lampe, E; Villar, L M
2017-11-01
This study aims to compare the efficiency of four oral fluid collection methods (Salivette, FTA Card, spitting and DNA-Sal) to detect HBV DNA by qualitative PCR. Seventy-four individuals (32 HBV reactive and 42 with no HBV markers) donated serum and oral fluid. In-house qualitative PCR to detect HBV was used for both samples and commercial quantitative PCR for serum. HBV DNA was detected in all serum samples from HBV-infected individuals, and it was not detected in control group. HBV DNA from HBV group was detected in 17 samples collected with Salivette device, 16 samples collected by FTA Card device, 16 samples collected from spitting and 13 samples collected by DNA-Sal device. Samples that corresponded to a higher viral load in their paired serum sample could be detected using all oral fluid collection methods, but Salivette collection device yielded the largest numbers of positive samples and had a wide range of viral load that was detected. It was possible to detect HBV DNA using all devices tested, but higher number of positive samples was observed when samples were collected using Salivette device, which shows high concordance to viral load observed in the paired serum samples. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.
Therapeutic drug monitoring of caffeine in preterm infants: Could saliva be an alternative to serum?
Chaabane, Amel; Chioukh, Fatma Z; Chadli, Zohra; Ben Fredj, Nadia; Ben Ameur, Karim; Ben Hmida, Hayet; Boughattas, Naceur A; Monastiri, Kamel; Aouam, Karim
2017-12-01
Evaluate whether saliva could be a useful alternative to serum for routine therapeutic drug monitoring of caffeine in preterm infants using the enzyme multiplied immunoassay technique (EMIT) assay. We conducted a prospective study including preterm infants (less than 34 weeks' amenorrhea) admitted to the intensive care and neonatal medicine department. All infants received 5, 10, 15, 20 and 25mg/kg/day of citrate caffeine intravenously from the first to the fifth day of birth, respectively. For each patient, two concomitant blood and saliva samples corresponding to the trough concentrations were collected 24hours after each caffeine dose. The caffeine concentrations were determined using the EMIT ® 2000 caffeine assay. Thirteen preterm infants were included. The saliva and the serum caffeine concentration increased proportionally to the administered dose. Saliva and serum kinetics were comparable and the saliva caffeine concentrations were correlated to the serum ones (r 2 =0.76). Saliva caffeine monitoring by EMIT is a valid, useful and safe alternative to serum in preterm infants. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.
He, Jin-Xin; Thirumalai, Diraviyam; Schade, Rüdiger; Zhang, Xiao-Ying
2014-08-15
IgY is the functional equivalent of mammalian IgG found in birds, reptiles and amphibians. Many of its biological aspects have been explored with different approaches. In order to evaluate the rhythmicity of serum and yolk IgY, four chickens were examined and reared under the same conditions. To monitor biological oscillations of IgY in yolk and serum, the eggs and blood samples were collected over a 60 day period and the rhythm of yolk and serum IgY was determined by direct-ELISA. Results indicated that, there is a significant circaseptan rhythm in yolk IgY and circaquattran rhythm in serum IgY. The serum IgY concentration reached a peak in the morning, decreased to a minimum during the daytime and increased again at night revealing a significant circadian rhythm was superimposed by an ultradian rhythm. These data are suited to address the controversies concerning the IgY concentration in egg yolk and blood of laying hens. In addition, this study raised new questions, if the different rhythms in yolk and serum are concerned. Copyright © 2014 Elsevier B.V. All rights reserved.
Haptoglobin and serum amyloid A in bulk tank milk in relation to raw milk quality.
Akerstedt, Maria; Waller, Karin Persson; Sternesjö, Ase
2009-11-01
The aim of the present study was to evaluate relationships between the presence of the two major bovine acute phase proteins haptoglobin (Hp) and serum amyloid A (SAA) and raw milk quality parameters in bulk tank milk samples. Hp and SAA have been suggested as specific markers of mastitis but recently also as markers for raw milk quality. Since mastitis has detrimental effects on milk quality, it is important to investigate whether the presence of Hp or SAA indicates such changes in the composition and properties of the milk. Bulk tank milk samples (n=91) were analysed for Hp, SAA, total protein, casein, whey protein, proteolysis, fat, lactose, somatic cell count and coagulating properties. Samples with detectable levels of Hp had lower casein content, casein number and lactose content, but higher proteolysis than samples without Hp. Samples with detectable levels of SAA had lower casein number and lactose content, but higher whey protein content than samples without SAA. The presence of acute phase proteins in bulk tank milk is suggested as an indicator for unfavourable changes in the milk composition, e.g. protein quality, due to udder health disturbances, with economical implications for the dairy industry.
Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem
2016-04-01
A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.
Nikolac Gabaj, Nora; Miler, Marijana; Vrtarić, Alen; Hemar, Marina; Filipi, Petra; Kocijančić, Marija; Šupak Smolčić, Vesna; Ćelap, Ivana; Šimundić, Ana-Maria
2018-04-25
The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.
Multicenter performance evaluation of a second generation cortisol assay.
Vogeser, Michael; Kratzsch, Jürgen; Ju Bae, Yoon; Bruegel, Mathias; Ceglarek, Uta; Fiers, Tom; Gaudl, Alexander; Kurka, Hedwig; Milczynski, Christoph; Prat Knoll, Cristina; Suhr, Anna C; Teupser, Daniel; Zahn, Ingrid; Ostlund, Richard E
2017-05-01
Untreated disorders of the adrenocortical system, such as Cushing's or Addison's disease, can be fatal, and accurate quantification of a patient's cortisol levels is vital for diagnosis. The objective of this study was to assess the analytical performance of a new fully-automated Elecsys® Cortisol II assay (second generation) to measure cortisol levels in serum and saliva. Four European investigational sites assessed the intermediate precision and reproducibility of the Cortisol II assay (Roche Diagnostics) under routine conditions. Method comparisons of the Cortisol II assay vs. liquid chromatography-tandem mass spectrometry (LC-MS/MS), the gold standard for cortisol measurement, were performed. Cortisol reference ranges from three US sites were determined using samples from self-reported healthy individuals. The coefficients of variation (CVs) for repeatability, intermediate precision, and reproducibility for serum samples were ≤2.6%, ≤5.8%, and ≤9.5%, respectively, and for saliva were ≤4.4% and ≤10.9%, and ≤11.4%, respectively. Agreement between the Cortisol II assay and LC-MS/MS in serum samples was close, with a slope of 1.02 and an intercept of 4.473 nmol/L. Reference range samples were collected from healthy individuals (n=300) and serum morning cortisol concentrations (5-95th percentile) were 166.1-507 nmol/L and afternoon concentrations were 73.8-291 nmol/L. Morning, afternoon, and midnight saliva concentrations (95th percentile) were 20.3, 6.94, and 7.56 nmol/L, respectively. The Cortisol II assay had good precision over the entire measuring range and had excellent agreement with LC-MS/MS. This test was found suitable for routine diagnostic application and will be valuable for the diagnosis of adrenocortical diseases.
Fernández-Real, José Manuel; Moreno, José María; Ricart, Wifredo
2008-01-01
OBJECTIVES—The mechanisms behind the association between retinol-binding protein-4 (RBP4) and insulin resistance are not well understood. An interaction between iron and vitamin A status, of which RBP4 is a surrogate, has long been recognized. We hypothesized that iron-associated insulin resistance could be behind the impaired insulin action caused by RBP4. RESEARCH DESIGN AND METHODS—Serum ferritin and RBP4 concentration and insulin resistance were evaluated in a sample of middle-aged men (n = 132) and in a replication independent study. Serum RBP4 was also studied before and after iron depletion in patients with type 2 diabetes. Finally, the effect of iron on RBP4 release was evaluated in vitro in adipose tissue. RESULTS—A positive correlation between circulating RBP4 and log serum ferritin (r = 0.35 and r = 0.61, respectively; P < 0.0001) was observed in both independent studies. Serum RBP4 concentration was higher in men than women in parallel to increased ferritin levels. On multiple regression analyses to predict serum RBP4, log serum ferritin contributed significantly to RBP4 variance after controlling for BMI, age, and homeostasis model assessment value. Serum RBP4 concentration decreased after iron depletion in type 2 diabetic patients (percent mean difference −13.7 [95% CI −25.4 to −2.04]; P = 0.024). The iron donor lactoferrin led to increased dose-dependent adipose tissue release of RBP4 (2.4-fold, P = 0.005) and increased RBP4 expression, while apotransferrin and deferoxamine led to decreased RBP4 release. CONCLUSIONS—The relationship between circulating RBP4 and iron stores, both cross-sectional and after iron depletion, and in vitro findings suggest that iron could play a role in the RBP4–insulin resistance relationship. PMID:18426863
Sattler, Annika; Schaefer, Marion; May, Theodor W
2015-09-01
To evaluate the relationship between serum concentrations of mono-hydroxy-carbazepine (MHD), the main metabolite of oxcarbazepine (OXC), and the occurrence of adverse effects (AE) in a large group of patients on OXC monotherapy. An antiepileptic drug (AED) therapeutic drug monitoring (TDM) database was analyzed especially with regard to OXC dosage, MHD serum concentration, and the occurrence of AE. In total, 893 blood samples of 442 patients were included in this retrospective study. The statistical evaluation was performed by means of Kaplan-Meier estimates, log-rank tests and generalized estimating equations (GEE). At least one AE was reported in 78 (17.6%) of the 442 patients. At MHD serum concentrations of 30.0 μg/ml and 43.7 μg/ml and OXC dosages of 33.1 mg/kg and 62.3 mg/kg, 25% and 75% of patients, respectively, experienced at least one AE. Log-rank tests indicated that younger patients (<18 years) may be able to tolerate higher MHD serum levels (p = 0.006) and higher OXC dosages per body weight (p < 0.001) compared to adult patients (≥ 18 years). Furthermore, AEs occurred at higher body-weight adjusted OXC dosages of extended release formulations compared to immediate-release formulations (p = 0.010), whereas MHD serum levels at which AEs occurred did not differ significantly between formulations (p = 0.125). Multivariate GEE confirmed the results. The occurrence of AEs is significantly (and non-linearly) dependent on MHD serum level, whereas the dependence of OXC dosage is less distinctive. But, tolerability of OXC seems to depend on age of the patients as well as on pharmaceutical formulation of OXC. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Costas-Rodríguez, Marta; Anoshkina, Yulia; Lauwens, Sara; Van Vlierberghe, Hans; Delanghe, Joris; Vanhaecke, Frank
2015-03-01
The isotopic composition of blood serum Cu has been investigated as a potential parameter for the diagnosis and prognosis of liver cirrhosis. Serum samples from supposedly healthy women (reference population) and from a group of female patients suffering from liver cirrhosis of different etiologies were analysed. The procedure for isolation of serum Cu and the measurement protocol for its isotopic analysis by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) were evaluated. Significant differences in the isotopic composition of Cu were observed between the reference population and the patients. A wide spread in δ(65)Cu was observed within the cirrhosis population and δ(65)Cu seems to be linked to the severity of the disease. Patients with end-stage liver disease showed a significantly lighter serum Cu isotopic composition. Many clinical parameters used for the diagnosis and monitoring of liver diseases, i.e. the levels of aspartate aminotransferase, De Ritis ratio, prothrombin and international normalized ratio, albumin, bilirubin, Na and C-reactive protein, correlate well with the δ(65)Cu values, as did the ceruloplasmin level and the ceruloplasmin/Cu concentration ratio. The isotopic composition of serum Cu appears to reveal the synthetic and hepatocellular function of the liver synergistically with inflammation and fluid retention in the cohort studied. A relevant relationship was also observed between δ(65)Cu and scores of mortality risk, such as the Model for End-stage Liver Disease (MELD) and MELD-Na. Thus, the isotopic composition of serum Cu shows potential as a new approach for the prognosis of liver disease, and although further investigation is required, for evaluation of the mortality risk in end-stage liver disease and prioritization of liver transplants.
Serum free light chain reference values: a critical approach.
Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario
2013-05-01
The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.
Serum PARC/CCL-18 concentrations and health outcomes in chronic obstructive pulmonary disease.
Sin, Don D; Miller, Bruce E; Duvoix, Annelyse; Man, S F Paul; Zhang, Xuekui; Silverman, Edwin K; Connett, John E; Anthonisen, Nicholas A; Wise, Robert A; Tashkin, Donald; Celli, Bartolome R; Edwards, Lisa D; Locantore, Nicholas; Macnee, William; Tal-Singer, Ruth; Lomas, David A
2011-05-01
There are no accepted blood-based biomarkers in chronic obstructive pulmonary disease (COPD). Pulmonary and activation-regulated chemokine (PARC/CCL-18) is a lung-predominant inflammatory protein that is found in serum. To determine whether PARC/CCL-18 levels are elevated and modifiable in COPD and to determine their relationship to clinical end points of hospitalization and mortality. PARC/CCL-18 was measured in serum samples from individuals who participated in the ECLIPSE (Evaluation of COPD Longitudinally to Identify Predictive Surrogate Endpoints) and LHS (Lung Health Study) studies and a prednisolone intervention study. Serum PARC/CCL-18 levels were higher in subjects with COPD than in smokers or lifetime nonsmokers without COPD (105 vs. 81 vs. 80 ng/ml, respectively; P < 0.0001). Elevated PARC/CCL-18 levels were associated with increased risk of cardiovascular hospitalization or mortality in the LHS cohort and with total mortality in the ECLIPSE cohort. Serum PARC/CCL-18 levels are elevated in COPD and track clinical outcomes. PARC/CCL-18, a lung-predominant chemokine, could be a useful blood biomarker in COPD.
The acute-phase proteins serum amyloid A and C reactive protein in transudates and exudates.
Okino, Alessandra M; Bürger, Cristiani; Cardoso, Jefferson R; Lavado, Edson L; Lotufo, Paulo A; Campa, Ana
2006-01-01
The distinction between exudates and transudates is very important in the patient management. Here we evaluate whether the acute-phase protein serum amyloid A (SAA), in comparison with C reactive protein (CRP) and total protein (TP), can be useful in this discrimination. CRP, SAA, and TP were determined in 36 exudate samples (27 pleural and 9 ascitic) and in 12 transudates (9 pleural and 3 ascitic). CRP, SAA, and TP were measured. SAA present in the exudate corresponded to 10% of the amount found in serum, that is, the exudate/serum ratio (E/S) was 0.10 +/- 0.13. For comparison, the exudate/serum ratio for CRP and TP was 0.39 +/- 0.37 and 0.68 +/- 0.15, respectively. There was a strong positive correlation between serum and exudate SAA concentration (r = 0.764; p < 0.0001). The concentration of SAA in transudates was low and did not overlap with that found in exudates (0.02-0.21 versus 0.8-360.5 g/mL). SAA in pleural and ascitic exudates results mainly from leakage of the serum protein via the inflamed membrane. A comparison of the E/S ratio of SAA and CRP points SAA as a very good marker in discriminating between exudates and transudates.
The Acute-Phase Proteins Serum Amyloid A and C Reactive Protein in Transudates and Exudates
Okino, Alessandra M.; Bürger, Cristiani; Cardoso, Jefferson R.; Lavado, Edson L.; Lotufo, Paulo A.; Campa, Ana
2006-01-01
The distinction between exudates and transudates is very important in the patient management. Here we evaluate whether the acute-phase protein serum amyloid A (SAA), in comparison with C reactive protein (CRP) and total protein (TP), can be useful in this discrimination. CRP, SAA, and TP were determined in 36 exudate samples (27 pleural and 9 ascitic) and in 12 transudates (9 pleural and 3 ascitic). CRP, SAA, and TP were measured. SAA present in the exudate corresponded to 10% of the amount found in serum, that is, the exudate/serum ratio (E/S) was 0.10 ± 0.13. For comparison, the exudate/serum ratio for CRP and TP was 0.39 ± 0.37 and 0.68 ± 0.15, respectively. There was a strong positive correlation between serum and exudate SAA concentration (r = 0.764;p < 0.0001). The concentration of SAA in transudates was low and did not overlap with that found in exudates (0.02-0.21 versus 0.8–360.5 g/mL). SAA in pleural and ascitic exudates results mainly from leakage of the serum protein via the inflamed membrane. A comparison of the E/S ratio of SAA and CRP points SAA as a very good marker in discriminating between exudates and transudates. PMID:16864904
Serum 25-hyroxyvitamin D levels and tic severity in Chinese children with tic disorders.
Li, Hong-Hua; Shan, Ling; Wang, Bing; Du, Lin; Xu, Zhi-Da; Jia, Fei-Yong
2018-05-31
The aim of this study is to evaluate serum 25-hydroxyvitamin D[25(OH)D] levels in children with tic disorders and to explore the relationship between serum 25(OH)D level and tic severity. Children (n = 179, 31 females, 148 males, mean age at diagnosis: 8.0 ± 2.7 years old, age ranged from 3 to 14.5 years old) who were diagnosed with a tic disorder were enrolled as case group, 189 healthy children were recruited as control group. Serum level of 25(OH)D of each child was measured by high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS). Yale Global Tic Severity Scale (YGTSS) was used to assess tic severity. Mean serum level of 25(OH)D in the case group was significantly lower than that of the control group. The serum 25(OH)D level was significantly associated with tic severity after adjusting for age and body mass index (BMI). This study identified a high prevalence of vitamin D insufficiency or deficiency in children with tic disorders, and there was a negative correlation between the serum 25(OH)D level and tic severity. In the future, large sample size studies are urgently needed to further clarify this correlation. Copyright © 2018. Published by Elsevier B.V.
Implementing self sustained quality control procedures in a clinical laboratory.
Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N
2013-01-01
Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.
Katsoulos, Panagiotis D; Athanasiou, Labrini V; Karatzia, Maria A; Giadinis, Nektarios; Karatzias, Harilaos; Boscos, Constantin; Polizopoulou, Zoe S
2017-12-01
Determination of serum total protein concentration is commonly performed by the biuret method. Refractometric measurement is a faster and less expensive alternative but its accuracy has not been determined in ruminants. The purpose of the study was to compare the serum total protein concentrations in cattle, sheep, and goats measured by the biuret method with those obtained by refractometry. Serum total protein concentration was determined in 120 cattle, 67 sheep, and 58 goat blood samples refractometrically and with the biuret method. The data were analyzed with a paired samples t-test, and Passing and Bablok regression equations and Bland and Altman plots were generated. There was a strong linear relationship between the total protein values determined with the refractometer and the biuret method in cattle, sheep, and goats. The statistical accuracy, which represents a bias correction factor that measures the deviation of the best-fit line from the 45° line through the origin, was 90.63% for cattle, 93.05% for sheep, and 91.76% for goats. The mean protein values determined with the refractometer were significantly lower than those measured with the biuret method in cattle and goats (P < .05) but not in sheep (P > .05). The evaluated refractometer was sufficiently accurate for the determination of serum total proteins in cattle, sheep, and goats, although it cannot be used interchangeably with the biuret method. The RIs should be corrected for negative bias based on the created equations. © 2017 American Society for Veterinary Clinical Pathology.
Franklin, Ashley D; Crosier, Adrienne E; Vansandt, Lindsey M; Mattson, Elliot; Xiao, Zhengguo
2015-06-01
Peripheral blood mononuclear cells (PBMCs) were isolated from the whole blood of cheetahs (Acinonyx jubatus ; n=3) and stimulated with lipopolysaccharides (LPS) to induce the production of proinflammatory cytokines TNF-α, IL-1β, and IL-6 for establishment of cross-reactivity between these cheetah cytokines and feline-specific cytokine antibodies provided in commercially available Feline DuoSet® ELISA kits (R&D Systems, Inc., Minneapolis, Minnesota 55413, USA). This study found that feline-specific cytokine antibodies bind specifically to cheetah proinflammatory cytokines TNF-α, IL-1β, and IL-6 from cell culture supernatants. The assays also revealed that cheetah PBMCs produce a measurable, cell concentration-dependent increase in proinflammatory cytokine production after LPS stimulation. To enable the use of these kits, which are designed for cell culture supernatants for analyzing cytokine concentrations in cheetah serum, percent recovery and parallelism of feline cytokine standards in cheetah serum were also evaluated. Cytokine concentrations in cheetah serum were approximated based on the use of domestic cat standards in the absence of cheetah standard material. In all cases (for cytokines TNF-α, IL-1β, and IL-6), percent recovery increased as the serum sample dilution increased, though percent recovery varied between cytokines at a given dilution factor. A 1:2 dilution of serum resulted in approximately 45, 82, and 7% recovery of TNF-α, IL-1β, and IL-6 standards, respectively. Adequate parallelism was observed across a large range of cytokine concentrations for TNF-α and IL-1β; however, a significant departure from parallelism was observed between the IL-6 standard and the serum samples (P=0.004). Therefore, based on our results, the Feline DuoSet ELISA (R&D Systems, Inc.) kits are valid assays for the measurement of TNF-α and IL-1β in cheetah serum but should not be used for accurate measurement of IL-6.
Wang, Who-Whong; Ang, Soo Fan; Kumar, Rajneesh; Heah, Charmain; Utama, Andi; Tania, Navessa Padma; Li, Huihua; Tan, Sze Huey; Poo, Desmond; Choo, Su Pin; Chow, Wan Cheng; Tan, Chee Kiat; Toh, Han Chong
2013-01-01
Early diagnosis of hepatocellullar carcinoma (HCC) remains a challenge. The current practice of serum alpha-fetoprotein (AFP) measurement is inadequate. Here we utilized a proteomic approach to identify novel serum biomarkers for distinguishing HCC patients from non-cancer controls. We profiled the serum proteins in a group of 58 resectable HCC patients and 11 non-HCC chronic hepatitis B (HBV) carrier samples from the Singapore General Hospital (SGH) using the RayBio® L-Series 507 Antibody Array and found 113 serum markers that were significantly modulated between HCC and control groups. Selected potential biomarkers from this list were quantified using a multiplex sandwich enzyme-linked immunosorbent assay (ELISA) array in an expanded SGH cohort (126 resectable HCC patients and 115 non-HCC chronic HBV carriers (NC group)), confirming that serum prolactin and monocyte chemoattractant protein-1 (MCP-1) were significantly upregulated in HCC patients. This finding of serum MCP-1 elevation in HCC patients was validated in a separate cohort of serum samples from the Mochtar Riady Institute for Nanotechnology, Indonesia (98 resectable HCC, 101 chronic hepatitis B patients and 100 asymptomatic HBV/HCV carriers) by sandwich ELISA. MCP-1 and prolactin levels were found to correlate with AFP, while MCP-1 also correlated with disease stage. Subsequent receiver operating characteristic (ROC) analysis of AFP, prolactin and MCP-1 in the SGH cohort and comparing their area under the ROC curve (AUC) indicated that neither prolactin nor MCP-1 on their own performed better than AFP. However, the combination of AFP+MCP-1 (AUC, 0.974) had significantly superior discriminative ability than AFP alone (AUC, 0.942; p<0.001). In conclusion, prolactin and MCP-1 are overexpressed in HCC and are conveniently quantifiable in patients' sera by ELISA. MCP-1 appears to be a promising complementary biomarker for HCC diagnosis and this MCP-1+AFP model should be further evaluated as potential biomarker on a larger scale in patients at-risk of HCC.
Kumar, Rajneesh; Heah, Charmain; Utama, Andi; Tania, Navessa Padma; Li, Huihua; Tan, Sze Huey; Poo, Desmond; Choo, Su Pin; Chow, Wan Cheng; Tan, Chee Kiat; Toh, Han Chong
2013-01-01
Early diagnosis of hepatocellullar carcinoma (HCC) remains a challenge. The current practice of serum alpha-fetoprotein (AFP) measurement is inadequate. Here we utilized a proteomic approach to identify novel serum biomarkers for distinguishing HCC patients from non-cancer controls. We profiled the serum proteins in a group of 58 resectable HCC patients and 11 non-HCC chronic hepatitis B (HBV) carrier samples from the Singapore General Hospital (SGH) using the RayBio® L-Series 507 Antibody Array and found 113 serum markers that were significantly modulated between HCC and control groups. Selected potential biomarkers from this list were quantified using a multiplex sandwich enzyme-linked immunosorbent assay (ELISA) array in an expanded SGH cohort (126 resectable HCC patients and 115 non-HCC chronic HBV carriers (NC group)), confirming that serum prolactin and monocyte chemoattractant protein-1 (MCP-1) were significantly upregulated in HCC patients. This finding of serum MCP-1 elevation in HCC patients was validated in a separate cohort of serum samples from the Mochtar Riady Institute for Nanotechnology, Indonesia (98 resectable HCC, 101 chronic hepatitis B patients and 100 asymptomatic HBV/HCV carriers) by sandwich ELISA. MCP-1 and prolactin levels were found to correlate with AFP, while MCP-1 also correlated with disease stage. Subsequent receiver operating characteristic (ROC) analysis of AFP, prolactin and MCP-1 in the SGH cohort and comparing their area under the ROC curve (AUC) indicated that neither prolactin nor MCP-1 on their own performed better than AFP. However, the combination of AFP+MCP-1 (AUC, 0.974) had significantly superior discriminative ability than AFP alone (AUC, 0.942; p<0.001). In conclusion, prolactin and MCP-1 are overexpressed in HCC and are conveniently quantifiable in patients’ sera by ELISA. MCP-1 appears to be a promising complementary biomarker for HCC diagnosis and this MCP-1+AFP model should be further evaluated as potential biomarker on a larger scale in patients at-risk of HCC. PMID:23874805
The diagnostic effect of serum miR-196b as biomarker in colorectal cancer
Xu, Chunjie; Gu, Lei
2017-01-01
The microRNA, miR-196b, serves a role in normal cell differentiation, proliferation and tumorigenesis of different types of cancer. The aim of the present study was to explore the serum expression of miR-196b in colorectal cancer (CRC) and its correlation with clinicopathological features. Sera samples were obtained from 103 patients with CRC, 51 patients with colorectal adenoma (Ad) and 100 healthy individuals for the present study. The serum expression of miR-196b in sera samples of the three cohorts was detected using reverse transcription-quantitative polymerase chain reaction. The diagnostic value of miR-196b in the serum of the patients with CRC was evaluated by receiver operating characteristic (ROC) curve and survival analysis, using the Kaplan-Meier method, which was performed with the data from a 5-year follow-up. The expression of miR-196b in the serum of patients with CRC was significantly higher compared with that in Ad patients or healthy individuals (all P<0.001), and the overexpression of serum miR-196b was clearly associated with lymph node invasion, differentiation, and the tumor-lymph nodes-metastasis stage (all P<0.05). ROC curve analysis demonstrated that, comparing patients with CRC with healthy individuals, the area under the curve of serum miR-196b was 0.8135, and its specificity and sensitivity were 63 and 87.38%, respectively, at a diagnostic threshold of −4.785. Patients with CRC of miR-196b-high status had shorter overall survival and disease-free survival rates compared with those of miR-196b-low status. In conclusion, the results of the present study demonstrated that serum miR-196b is upregulated in CRC, and may have an application as a diagnostic and prognostic biomarker for patients with CRC. PMID:28123705
Eleutherakis-Papaiakovou, Evangelos; Kastritis, Efstathios; Gavriatopoulou, Maria; Christoulas, Dimitrios; Roussou, Maria; Ntanasis-Stathopoulos, Ioannis; Kanellias, Nikolaos; Papatheodorou, Athanasios; Dimopoulos, Meletios A; Terpos, Evangelos
2018-06-01
Serum receptor activator of nuclear factor κB ligand (sRANKL) and chemokine (C-C) motif ligand 3 (CCL-3) have been reported to be elevated in Waldenström macroglobulinemia (WM) patients. However, there are no published data regarding the prognostic value of these molecules in WM regarding progression-free and overall survival. To evaluate the effect of these markers of bone remodeling on survival parameters, we prospectively evaluated serum cytokines and biological markers in 55 patients with symptomatic WM before they received any kind of treatment. Serum levels of CCL-3 and bone remodeling markers were also evaluated in asymptomatic WM and IgM monoclonal gammopathy of undetermined significance. Furthermore, we assessed bone marrow biopsy samples from newly diagnosed WM patients for CCL-3 and RANKL expression. High circulating sRANKL values predicted shorter median overall survival (46 months vs. not reached, P = .025). High serum levels of CCL-3 predicted shorter median progression-free survival (27 months vs. not reached, P = .048). At bone marrow biopsy evaluation, the whole number of the neoplastic cells revealed strong cytoplasmic positivity for CCL-3, while the neoplastic clone did not express RANKL. We conclude that WM cells produce CCL-3 and possibly enhance the production of RANKL in the bone microenvironment. The correlation of sRANKL and CCL-3 with survival reveals the importance of these cytokines in disease biology and highlights the significance of the interactions between WM and stromal cells for the development of WM. Finally, these findings provide the rationale for the use of anti-RANKL and anti-CCL-3 drugs in animal models of WM before their clinical evaluation. Copyright © 2018 Elsevier Inc. All rights reserved.
Choi, Hyon K; Curhan, Gary
2007-06-15
Coffee is one of the most widely consumed beverages in the world and may affect serum uric acid levels and risk of gout via various mechanisms. Our objective was to evaluate the relationship between coffee, tea, and caffeine intake and serum uric acid level in a nationally representative sample of men and women. Using data from 14,758 participants ages >/=20 years in the Third National Health and Nutrition Examination Survey (1988-1994), we examined the relationship between coffee, tea, and caffeine intake and serum uric acid level using linear regression. Additionally, we examined the relationship with hyperuricemia (serum uric acid >7.0 mg/dl among men and >5.7 mg/dl among women) using logistic regression. Intake was assessed by a food frequency questionnaire. Serum uric acid level decreased with increasing coffee intake. After adjusting for age and sex, serum uric acid level associated with coffee intake of 4 to 5 and >/=6 cups daily was lower than that associated with no intake by 0.26 mg/dl (95% confidence interval [95% CI] 0.11, 0.41) and 0.43 mg/dl (95% CI 0.23, 0.65; P for trend < 0.001), respectively. After adjusting for other covariates, the differences remained significant (P for trend < 0.001). Similarly, there was a modest inverse association between decaffeinated coffee intake and serum uric acid levels (multivariate P for trend 0.035). Total caffeine from coffee and other beverages and tea intake were not associated with serum uric acid levels (multivariate P for trend 0.15). The multivariate odds ratio for hyperuricemia in individuals with coffee intake >/=6 cups daily compared with those with no coffee use was 0.57 (95% CI 0.35, 0.94; P for trend 0.001). These findings from a nationally representative sample of US adults suggest that coffee consumption is associated with lower serum uric acid level and hyperuricemia frequency, but tea consumption is not. The inverse association with coffee appears to be via components of coffee other than caffeine.
Liang, Si; Xu, Feng; Tang, Weibiao; Zhang, Zheng; Zhang, Wei; Liu, Lili; Wang, Junxia; Lin, Kuangfei
2016-08-01
Hair samples and paired serum samples were collected from e-waste and urban areas in Wenling of Zhejiang Province, China. The PBDE and DBDPE concentrations in hair and serum samples from e-waste workers were significantly higher than those of non-occupational residents and urban residents. BDE209 was the dominating BFRs in hair and serum samples from the e-waste area, while DBDPE was the major BFRs from the urban area. Statistically significant correlations were observed between hair level and serum level for some substances (BDE209, DBDPE, BDE99, BDE47, BDE28, and BDE17), although the PBDE congener profiles in hair were different from those in the serum. A statistically significant positive correlation between the PBDE concentrations and the working age, as well as gender difference, was observed in e-waste workers. Different sources of PBDEs and DBDPE in three groups were identified by principal component analysis and spearman correlation coefficient. Hair is suggested to be a useful matrix for biomonitoring the PBDE exposure in humans.
Litwiniuk, Małgorzata; Niemczyk, Kazimierz; Niderla-Bielińska, Justyna; Łukawska-Popieluch, Izabela; Grzela, Tomasz
2017-10-01
To assess the expression of endoglin in head and neck paragangliomas and the soluble endoglin level in serum of paraganglioma patients. Seven tumor samples of patients operated for cervical paraganglioma were assessed, as well as serum samples collected preoperatively, on days 4 and 28 postoperation. Serum level of endoglin in healthy controls was also determined. Tumor samples were subjected to immunofluorescent staining and examined with confocal microscope. The level of soluble endoglin in serum samples was examined using the immunoenzymatic assay (ELISA). Endoglin was highly expressed in all tumor samples. The level of soluble endoglin was significantly higher in paraganglioma patients compared to healthy controls and correlated with the tumor size. The serum level of s-endoglin was reduced after surgical excision of the tumor and remained stable after 4 weeks in all patients with complete resection of the tumor. Endoglin is an important factor in the pathophysiology of head and neck paragangliomas and may be a potential diagnostic and prognostic marker in these types of tumors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyle, Jennifer E.; Casey, Cameron P.; Stratton, Kelly G.
The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules weremore » identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.« less
Automation of a spectrophotometric method for measuring L -carnitine in human blood serum.
Galan, A; Padros, A; Arambarri, M; Martin, S
1998-01-01
A spectrometric method for the determination of L-carnitine has been developed based on the reaction of the 5,5' dithiobis-(2-nitrobenzoic) acid (DTNB) and adapted to a Technicon RA-2000 automatic analyser Química Farmacéutica Bayer, S.A.). The detection limit of the method is 13.2 mumol/l, with a measurement interval ranging from 30 to 320 mumoll1. Imprecision and accuracy are good even at levels close to the detection limit (coeffcient of variation of 5.4% for within-run imprecision for a concentration of 35 mumol/l). A good correlation was observed between the method studied and the radiometric method. The method evaluated has suffcient analytical sensitivity to diagnose carnitine deficiencies. The short time period required for sample processing (30 samples in 40min), the simple methodology and apparatus, the ease of personnel training and the low cost of the reagents make this method a good alternative to the classical radiometric method for evaluating serum L-carnitine in clinical laboratories without radioactive installations.
Automation of a spectrophotometric method for measuring L -carnitine in human blood serum
Galan, Amparo; Padros, Anna; Arambarri, Marta; Martin, Silvia
1998-01-01
A spectrometric method for the determination of L-carnitine has been developed based on the reaction of the 5, 5 ′ dithiobis-(2-nitrobenzoic) acid (DTNB) and adapted to a Technicon RA-2000 automatic analyser Química Farmacéutica Bayer, S.A.). The detection limit of the method is 13.2 μmol/l, with a measurement interval ranging from 30 to 320 μmoll1. Imprecision and accuracy are good even at levels close to the detection limit (coeffcient of variation of 5.4% for within-run imprecision for a concentration of 35 μmol/l). A good correlation was observed between the method studied and the radiometric method. The method evaluated has suffcient analytical sensitivity to diagnose carnitine deficiencies. The short time period required for sample processing (30 samples in 40min), the simple methodology and apparatus, the ease of personnel training and the low cost of the reagents make this method a good alternative to the classical radiometric method for evaluating serum L-carnitine in clinical laboratories without radioactive installations. PMID:18924818
Evaluation of adverse effects of long-term orally administered carprofen in dogs.
Raekallio, Marja R; Hielm-Björkman, Anna K; Kejonen, Johanna; Salonen, Hanna M; Sankari, Satu M
2006-03-15
To evaluate the adverse effects of carprofen in dogs after oral administration for 2 months. Prospective, randomized, blinded, placebo-controlled clinical trial. 22 dogs with osteoarthritis in the hip or elbow joint. 13 dogs received orally administered carprofen daily for 2 months, and 9 dogs received a placebo for 2 months. Dogs were weighed, and serum and urine samples were collected before initiation of treatment and 4 and 8 weeks after initiation of treatment. Serum concentrations of total protein, albumin, urea, and creatinine and serum activities of alkaline phosphatase (ALP) and alanine aminotransferase (ALT) were measured. Urinary ALP-to-creatinine, gamma-glutamyltransferase (GGT)-to-creatinine, and protein-to-creatinine ratios were calculated. Dogs were observed by owners for adverse effects. Serum protein and albumin concentrations were lower in treated dogs than in those that received placebo at 4 weeks, but not at 8 weeks. No changes were observed in serum urea or creatinine concentrations; ALP or ALT activity; or urinary ALP-to-creatinine, GGT-to-creatinine, or protein-to-creatinine ratios. Dogs' weights did not change. Severity of vomiting, diarrhea, and skin reactions did not differ between groups, but appetite was better in dogs receiving carprofen than in dogs in the placebo group. It is possible that the transient decreases in serum protein and albumin concentrations in dogs that received carprofen were caused by altered mucosal permeability of the gastrointestinal tract because no indications of renal or hepatic toxicity were observed. Carprofen appeared to be well tolerated by dogs after 2 months of administration.
Panahi, Yunes; Davoudi, Seyyed Masoud; Beiraghdar, Fatemeh; Amiri, Mojtaba; Saadat, Alireza; Marzony, Eisa Tahmasbpour; Naghizadeh, Mohmad Mehdi; Sahebkar, Amirhossein
2013-01-01
Inflammation is a key component in the pathogenesis of sulfur mustard (SM)-induced skin complications. Here, the levels of interleukin (IL) -2, IL-4, IL-6, and IL-10 were evaluated in patients with chronic SM-induced complications. Seventy-four serum samples were collected from SM-injured veterans (SM group; n = 37) and nonchemically injured patients (control group; n = 37) with skin pruritus. The levels of IL-2, IL-4, IL-6, and IL-10 were evaluated by sandwich enzyme-linked immunosorbant assay technique in both nil and mitogen medium. No significant difference was found in pruritus score between SM (74.16 +/- 5.93) and control (74.48 +/- 6.15) groups (P > .05). The mean serum concentrations of IL-2 and IL-6 were found to be significantly elevated in the control compared with the SM group (P < .05). However, no significant difference was observed between the study groups regarding serum levels of IL-4 and IL-10 (P > .05). Serum IL-2 (in both SM and control groups) and IL-6 (in the control group) concentrations were significantly correlated with pruritus score while no significant association was found for IL-4 and IL-10. Serum concentrations of IL-2, IL-6, and IL-10 are significantly decreased in SM-exposed patients with chronic pruritus. Such alterations might represent a plausible mechanism for tissue damage and skin itching following SM exposure. Therefore, variation of ILs may also contribute to skin pruritus induced by SM.
Serum ischemia modified albumin is a possible new marker of oxidative stress in phenylketonuria.
Keshavarzi, Fatemeh; Rastegar, Mohsen; Vessal, Mahmood; Rafiei Dehbidi, Gholamreza; Khorsand, Marjan; Ganjkarimi, Amir Hossein; Takhshid, Mohammad Ali
2018-06-01
The role of oxidative stress in the pathogenesis of phenylketonuria (PKU)-associated disorders has been implicated. Ischemia modified albumin (IMA) is a modified form of serum albumin, which is produced under the conditions of oxidative stress. The aim of this study was to measure the serum level of IMA in the PKU patients and to investigate its ability in predicting the status of oxidative stress in these patients. Fifty treated-PKU patients and fifty age- and sex-matched healthy subjects were included in the study. The blood samples were obtained and the serum level of phenylalanine (Phe) was measured using reverse phase HPLC method. The levels of IMA, malondialdehyde (MDA), gamma-glutamyl transferase (GGT) activity, and uric acid (UA) were determined using colorimetric methods. The levels of serum Phe, IMA, and MDA were significantly higher (p < 0.001) and the level of UA (p < 0.05) was lower in the PKU patients compared to control group. Serum IMA level was positively correlated with MDA (r = 0.585, p < 0.001) and UA (r = 0.6, p < 0.001). An inverse relationship was observed between the serum level of IMA and Phe (r = - 0.410, p < 0. 01). Results of the present study suggest that serum IMA level could be used as a novel marker for the evaluation of oxidative stress in the PKU patients.
Biomonitoring Hexamethylene Diisocyanate (HDI) Exposure Based on Serum Levels of HDI-Specific IgG
Wisnewski, Adam V.; Stowe, Meredith H.; Nerlinger, Abby; Opare-addo, Paul; Decamp, David; Kleinsmith, Christopher R.; Redlich, Carrie A.
2012-01-01
Objectives: Isocyanate chemicals essential for polyurethane production are widely used industrially, and are increasingly found in consumer products. Asthma and other adverse health effects of isocyanates are well-documented and exposure surveillance is crucial to disease prevention. Hexamethylene diisocyanate (HDI)-specific serum immunoglobulin G (IgG) was evaluated as an exposure biomarker among workers at a US Air Force Air Logistics Center, which includes a large aircraft maintenance facility. Methods: HDI-specific IgG (HDI-IgG) titers in serum samples (n = 74) were measured using an enzyme-linked immunosorbent assay based upon the biuret form of HDI conjugated to human albumin. Information on personal protective equipment (PPE), work location/tasks, smoking, asthma history, basic demographics, and HDI skin exposure was obtained through questionnaire. Results: HDI-specific serum IgG levels were elevated in n = 17 (23%) of the workers studied. The prevalence and/or end-titer of the HDI-IgG was significantly (P < 0.05) associated with specific job titles, self-reported skin exposure, night-shift work, and respirator use, but not atopy, asthma, or other demographic information. The highest titers were localized to specific worksites (C-130 painting), while other worksites (generator painting) had no or few workers with detectable HDI-IgG. Conclusions: HDI-specific immune responses (IgG) provide a practical biomarker to aid in exposure surveillance and ongoing industrial hygiene efforts. The strategy may supplement current air sampling approaches, which do not assess exposures via skin, or variability in PPE use or effectiveness. The approach may also be applicable to evaluating isocyanate exposures in other settings, and may extend to other chemical allergens. PMID:22449630
Maki, Katsuyuki; Watabe, Etsuko; Iguchi, Yumi; Nakamura, Hideko; Tomishima, Masaki; Ohki, Hidenori; Yamada, Akira; Matsumoto, Satoru; Ikeda, Fumiaki; Tawara, Shuichi; Mutoh, Seitaro
2006-01-01
To establish an in vitro method of predicting in vivo efficacy of antifungal drugs against Candida albicans and Aspergillus fumigatus, the antifungal activities of fluconazole, itraconazole, and amphotericin B were determined in mouse serum. The minimum inhibitory concentration (MIC) of each drug was measured using mouse serum as a diluent. For C. albicans, the assay endpoint of azoles was defined as inhibition of mycelial extension (mMIC) and for A. fumigatus, as no growth (MIC). The MICs of amphotericin B for both pathogens were defined as the MIC at which no mycelial growth occurred. Serum MIC or mMIC determinations were then used to estimate the concentration of the drugs in serum of mice treated with antifungal drugs by multiplying the antifungal titer of the serum samples by the serum (m)MIC. The serum drug concentrations were also determined by HPLC. The serum concentrations estimated microbiologically showed good agreement with those determined by HPLC, except for itraconazole. Analysis of the serum samples from itraconazole-treated mice by a sensitive bioautography revealed the presence of additional spots, not seen in control samples of itraconazole. The bioautography assay demonstrated that the additional material detected in serum from mice treated with itraconazole was an active metabolite of itraconazole. The data showed that the apparent reduction in the itraconazole serum concentration as determined by HPLC was the result of the formation of an active metabolite, and that the use of a microbiological method to measure serum concentrations of drugs can provide a method for prediction of in vivo efficacy of antifungal drugs.
Gaze, David C; Prante, Christian; Dreier, Jens; Knabbe, Cornelius; Collet, Corinne; Launay, Jean-Marie; Franekova, Janka; Jabor, Antonin; Lennartz, Lieselotte; Shih, Jessie; del Rey, Jose Manuel; Zaninotto, Martina; Plebani, Mario; Collinson, Paul O
2014-06-01
Galectin-3 is secreted from macrophages and binds and activates fibroblasts forming collagen. Tissue fibrosis is central to the progression of chronic heart failure (CHF). We performed a European multicentered evaluation of the analytical performance of the two-step routine and Short Turn-Around-Time (STAT) galectin-3 immunoassay on the ARCHITECT i1000SR, i2000SR, and i4000SR (Abbott Laboratories). We evaluated the assay precision and dilution linearity for both routine and STAT assays and compared serum and plasma, and fresh vs. frozen samples. The reference interval and biological variability were also assessed. Measurable samples were compared between ARCHITECT instruments and between the routine and STAT assays and also to a galectin-3 ELISA (BG Medicine). The total assay coefficient of variation (CV%) was 2.3%-6.2% and 1.7%-7.4% for the routine and STAT assays, respectively. Both assays demonstrated linearity up to 120 ng/mL. Galectin-3 concentrations were higher in plasma samples than in serum samples and correlated well between fresh and frozen samples (R=0.997), between the routine and STAT assays, between the ARCHITECT i1000 and i2000 instruments and with the galectin-3 ELISA. The reference interval on 627 apparently healthy individuals (53% male) yielded upper 95th and 97.5th percentiles of 25.2 and 28.4 ng/mL, respectively. Values were significantly lower in subjects younger than 50 years. The galectin-3 routine and STAT assays on the Abbott ARCHITECT instruments demonstrated good analytical performance. Further clinical studies are required to demonstrate the diagnostic and prognostic potential of this novel marker in patients with CHF.
Opriessnig, Tanja; Hemann, Michelle; Johnson, John K; Heinen, Sheila; Giménez-Lirola, Luis G; O'Neill, Kevin C; Hoang, Hai; Yoon, Kyoung-Jin; Gottschalk, Marcelo; Halbur, Patrick G
2013-01-01
Accurate diagnosis of exposure to Actinobacillus pleuropneumoniae is important for maintaining negative farms. In the present study, the ability of a dual-plate complement fixation (CF) assay and 3 commercially available enzyme-linked immunosorbent assays (ELISAs; quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3) in detecting serological evidence of A. pleuropneumoniae exposure was compared using serum samples of experimentally infected or vaccinated pigs, or field samples from the United States. Forty-two pigs were divided into groups of 2 pigs and were inoculated with 1 of 15 A. pleuropneumoniae strains representing all known serovars of A. pleuropneumoniae, or with Actinobacillus suis, or were vaccinated with a bacterin containing A. pleuropneumoniae serovar 1, 3, 5, or 7. Serum samples collected at the day of inoculation or vaccination and 7, 14, 21, and 28 days later were used to compare the assays. On samples from experimentally infected pigs, the dual-plate CF assay, quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3 had sensitivities of 0.46, 0.74, 0.13, and 0.13 and specificities of 0.90, 1.0, 1.0, and 1.0, respectively. Vaccinated pigs were identified only by the dual-plate CF assay and the quad-plate ELISA-1. In addition, 90 serum samples with unknown A. pleuropneumoniae exposure collected under field conditions were tested with all assays. The agreement of the 4 assays on field samples was slight to fair. While several assays are available for demonstration of A. pleuropneumoniae exposure, differences in assay targets complicate test choices. Decisions on which assay or combination of assays to use depend on the specific reasons for running the assays.
Krämer, Michael; Heese, Peter; Banger, Markus; Madea, Burkhard; Hess, Cornelius
2018-06-01
Due to a lack of reference blood concentrations in the literature, the forensic evaluation of prothipendyl findings in blood samples is difficult. Interpretations with regard to the assessment of blood concentrations as well as an estimation of the ingested prothipendyl amounts were often vague. To describe a concentration range in clinical samples, prothipendyl and prothipendyl sulfoxide concentrations were determined in serum samples of 50 psychiatric patients receiving 40 mg, 80 mg, or 160 mg doses of prothipendyl. The analyses of prothipendyl and prothipendyl sulfoxide were carried out using validated methods of high performance liquid chromatography coupled to triple quadrupole mass spectrometry (LC-QQQ-MS), respectively. 40 mg doses caused average prothipendyl serum concentrations of 18.0 ng/mL (1 hour after intake) and 7.9 ng/mL (10.5 hours after intake), while 80 mg doses caused averages of 42.6 ng/mL and 15.2 ng/mL at the mentioned times of sampling. Irrespective of the given dose, prothipendyl concentrations below 30 ng/mL were observed in 80% of the patient samples taken 1 hour after ingestion as well as in 90% of the samples collected 10.5 hours after administration. Serum concentrations of the Phase I metabolite prothipendyl sulfoxide averaged 4.3 ng/mL (1 hour after intake) and 3.6 ng/mL (10.5 hours after intake). Possible drug-drug interactions regarding absorption and metabolism of prothipendyl are discussed. Results of the herein presented study are useful for the interpretation of analytical prothipendyl findings in forensic toxicology. The utility of the described concentration range is demonstrated by discussing two death cases involving prothipendyl findings. Copyright © 2017 John Wiley & Sons, Ltd.
Detection of Serum microRNAs From Department of Defense Serum Repository
Woeller, Collynn F.; Thatcher, Thomas H.; Van Twisk, Daniel; Pollock, Stephen J.; Croasdell, Amanda; Kim, Nina; Hopke, Philip K.; Xia, Xiaoyan; Thakar, Juilee; Mallon, COL Timothy M.; Utell, Mark J.; Phipps, Richard P.
2017-01-01
Objective The aim of this study was to investigate whether serum samples from the Department of Defense Serum Repository (DoDSR) are of sufficient quality to detect microRNAs (miRNAs), cytokines, immunoglobulin E (IgE), and polycyclic aromatic hydrocarbons (PAHs). Methods MiRNAs were isolated and quantified by polymerase chain reaction (PCR) array. Cytokines and chemokines related to inflammation were measured using multiplex immunoassays. Cotinine and IgE were detected by enzyme-linked immunoassay (ELISA) and PAHs were detected by Liquid Chromatography/Mass Spectroscopy. Results We detected miRNAs, cytokines, IgE, and PAHs with high sensitivity. Eleven of 30 samples tested positive for cotinine suggesting tobacco exposure. Significant associations between serum cotinine, cytokine, IgE, PAHs, and miRNA were discovered. Conclusion We successfully quantified over 200 potential biomarkers of occupational exposure from DoDSR samples. The stored serum samples were not affected by hemolysis and represent a powerful tool for biomarker discovery and analysis in retrospective studies. PMID:27501106
Costa, Nara Aline; Gut, Ana Lúcia; de Souza Dorna, Mariana; Pimentel, José Alexandre Coelho; Cozzolino, Silvia Maria Franciscato; Azevedo, Paula Schmidt; Fernandes, Ana Angélica Henrique; Zornoff, Leonardo Antonio Mamede; de Paiva, Sergio Alberto Rupp; Minicucci, Marcos Ferreira
2014-04-01
The purpose of the study is to determine the influence of serum thiamine, glutathione peroxidase (GPx) activity, and serum protein carbonyl concentrations in hospital mortality in patients with septic shock. This prospective study included all patients with septic shock on admission or during intensive care unit (ICU) stay, older than 18 years, admitted to 1 of the 3 ICUs of the Botucatu Medical School, from January to August 2012. Demographic information, clinical evaluation, and blood sample were taken within the first 72 hours of the patient's admission or within 72 hours after septic shock diagnosis for serum thiamine, GPx activity, and protein carbonyl determination. One hundred eight consecutive patients were evaluated. The mean age was 57.5 ± 16.0 years, 63% were male, 54.6% died in the ICU, and 71.3% had thiamine deficiency. Thiamine was not associated with oxidative stress. Neither vitamin B1 levels nor the GPx activity was associated with outcomes in these patients. However, protein carbonyl concentration was associated with increased mortality. In patients with septic shock, oxidative stress was associated with mortality. On the other hand, thiamine was not associated with oxidative stress or mortality in these patients. Copyright © 2014 Elsevier Inc. All rights reserved.
Evaluation of HBsAg and anti-HBc assays in saliva and dried blood spot samples according HIV status.
Flores, Geane Lopes; Cruz, Helena Medina; Potsch, Denise Vigo; May, Silvia Beatriz; Brandão-Mello, Carlos Eduardo; Pires, Marcia Maria Amendola; Pilotto, Jose Henrique; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo
2017-09-01
Influence of HIV status in HBV markers detection in saliva and dried blood spots (DBS) was not well established. This study aims to evaluate the performance of optimized commercial immunoassay for identifying HBsAg and anti-HBc in saliva and DBS according HIV status. A sum of 535 individuals grouped as HIV + , HBV + , HIV/HBV + and HIV/HBV- were recruited where 347 and 188 were included for HBsAg and anti-HBc evaluation, respectively. Serum, DBS collected in Whatman 903 paper and saliva obtained using salivette device were analyzed using EIA. Increased sample volume and ROC curve analysis for cut off determination were used for DBS and saliva testing. HBsAg detection in saliva and DBS exhibited sensitivities of 80.9% and 85.6% and specificities of 86.8% and 96.3%. Sensitivity of anti-HBc in saliva and DBS were 82.4% and 76.9% and specificities in saliva and DBS were 96.9% and 91.7%. Low sensitivities were observed for HBsAg (62%) and anti-HBc (47%) detection in saliva of HIV/HBV+ individuals. OD values were also lower for HBsAg detection in DBS and saliva of HIV/HBV+ individuals compared to their serum samples. Statistical significance was found for sensitivities in HBsAg detection between saliva and DBS demonstrating high sensitivity for DBS specimens. In conclusion, HIV status or antiretroviral treatment appears to interfere in the performance of HBsAg and anti-HBc detection in DBS and saliva samples using the adapted commercial EIA. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rocha-Osornio, L. N.; Pichardo-Molina, J. L.; Barbosa-Garcia, O.; Frausto-Reyes, C.; Araujo-Andrade, C.; Huerta-Franco, R.; Gutiérrez-Juárez, G.
2008-02-01
Raman spectroscopy and Multivariate methods were used to study serum blood samples of control and breast cancer patients. Blood samples were obtained from 11 patients and 12 controls from the central region of Mexico. Our results show that principal component analysis is able to discriminate serum sample of breast cancer patients from those of control group, also the loading vectors of PCA plotted as a function of Raman shift shown which bands permitted to make the maximum discrimination between both groups of samples.
The Platelia Aspergillus ELISA in diagnosis of invasive pulmonary aspergilosis (IPA).
Siemann, M; Koch-Dörfler, M
2001-01-01
The sensitivity of a sandwich enzyme-linked immunosorbent assay (ELISA) for detecting Aspergillus galactomannan was evaluated with 66 serum samples and 113 specimens of the respiratory tract obtained from 52 patients with pulmonary diseases. The patients were divided into five groups: proven invasive pulmonary aspergillosis (IPA) (five patients), probable IPA (seven patients), Aspergillus colonization (eight patients) or unlikely Aspergillus infection (27 patients). Another five patients with doubtful diagnostic test results are discussed in detail. The results of the Platelia Aspergillus ELISA (Sanofi Pasteur, Freiburg, Germany) in testing specimens of the respiratory tract were 90% sensitivity in proven (serum 38%), 60% in probable (serum 37%) and 71% in Aspergillus colonization (serum 0%). Furthermore, 85% of the Aspergillus spp. from positive cultures of specimens of the respiratory tract were also detected in the ELISA. A total of 57% of the culture negative specimens of patients with a least one positive culture or proven aspergillosis in a series of specimens were positive in the ELISA.
2004-01-01
Abstract Effects of dietary biotin supplementation on serum biotin levels and physical properties of sole horn of 40 Holstein cows were evaluated. The mean serum biotin level in biotin-supplemented cows after 10 mo of biotin supplementation (1163.2 ± 76.2 pg/mL) was significantly higher (P = 0.007) than that in control cows (382.0 ± 76.2 pg/mL). The sole horn of biotin-supplemented cows was significantly harder (P = 0.026) and had a significantly lower moisture content (P = 0.021) than that of control cows. No morphologic differences in horn tubules or intertubular horn were found between the biotin-supplemented and control cows. The total lipid content of sole horn was significantly higher (P = 0.030) in the biotin-supplemented cows than in the control cows. These results suggest that dietary biotin supplementation causes increases in serum biotin levels and changes in physical properties and fat content of sole horn. PMID:15188952
Monitoring of cellular enzymes in the serum of electroplating workers at Coimbatore.
Saraswathy, C P; Usharani, M V
2007-04-01
Chromium compounds are potent toxic and carcinogenic substances. With respect to toxicity, hepatic and renal toxicity have been reported both in workers and in animals exposed to chromium (VI). Chromium (VI) compounds induces DNA damage in vivo and in cultured cells as well as the cytotoxicity evaluated by the leakage of lactate dehydrogenase. The present study reports the cytotoxicity of chrome platers who are employed from 8 to 25 years in electroplating industries at Coimbatore, Tamilnadu. Blood samples were collected and estimated for glutamic oxaloacetic transaminase (GOT), glutamic pyruvic transaminase (GPT), alkaline phosphatase (ALP), lactate dehydrogenase (LDH), creatine phosphokinase (CPK) and total protein in the serum. The study revealed that there is a significant elevation in the level of LDH, ALP, CPK and transaminases and a decrease in total protein in serum. The results of the study suggests that chromium (VI), a hepatotoxic chemical may perhaps damage the plasma membrane resulting in leakage of enzymes in to the serum of chromeplaters.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study.
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Vazquez-Rosales, Guillermo; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Cevallos, Ana Maria; Xoconostle-Cazares, Beatriz; Lira, Rosalia
2017-01-01
Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µ l of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µ l. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Xoconostle-Cazares, Beatriz
2017-01-01
Background Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Methods Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion DSS samples are useful for detecting anti-dengue IgG antibodies in the field. PMID:28630868
Surface imprinted beads for the recognition of human serum albumin.
Bonini, Francesca; Piletsky, Sergey; Turner, Anthony P F; Speghini, Adolfo; Bossi, Alessandra
2007-04-15
The synthesis of poly-aminophenylboronic acid (ABPA) imprinted beads for the recognition of the protein human serum albumin (HSA) is reported. In order to create homogeneous recognition sites, covalent immobilisation of the template HSA was exploited. The resulting imprinted beads were selective for HSA. The indirect imprinting factor (IF) calculated from supernatant was 1.6 and the direct IF, evaluated from the protein recovered from the beads, was 1.9. The binding capacity was 1.4 mg/g, which is comparable to commercially available affinity materials. The specificity of the HSA recognition was evaluated with competitive experiments, indicating a molar ratio 4.5/1 of competitor was necessary to displace half of the bound HSA. The recognition and binding of the imprinted beads was also tested with a complex sample, human serum and targeted removal of HSA without a loss of the other protein components was demonstrated. The easy preparation protocol of derivatised beads and a good protein recognition properties make the approach an attractive solution to analytical and bio-analytical problems in the field of biotechnology.
Jensen, Berit P; Saraf, Rajneeta; Ma, Jing; Berry, Sarah; Grant, Cameron C; Camargo, Carlos A; Sies, Christiaan W
2018-06-01
Demand for measurement of 25-hydroxyvitamin D (25OHD) is growing and dried blood spot (DBS) sampling is attractive as samples are easier to collect, transport and store. A 2D LC-MS/MS assay without derivatization was developed. DBS punches (3.2 mm) were ultrasonicated with d 6 -25OHD 3 in 70% methanol followed by hexane extraction, dry-down and reconstitution. The assay was validated and applied to two studies comparing whole blood adult DBS with serum samples (n = 40) and neonatal whole blood DBS with cord serum samples (n = 80). The assay was validated in whole blood DBS over the range 13-106 nmol/L 25OHD 3 and 11-91 nmol/L 25OHD 2 with a limit of detection of 3 nmol/L. Intra- and inter-day imprecision was <13% CV and bias <12%. The assay had high recovery and minimal matrix effects. Triplicate DBS study samples had a mean CV of ≤13% for 25OHD 3. No 25OHD 2 was detected. DBS calculated serum 25OHD 3 concentrations correlated strongly with serum concentrations in the adult DBS/serum study (r = 0.94) and moderately in the neonatal DBS/cord serum study (r = 0.69). Direct quantitation of 25OHD in DBS by 2D LC-MS/MS without derivatization was found to be an alternative to serum quantitation applicable to clinical research studies on adult DBS samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Jeannot, Emmanuelle; Becette, Véronique; Campitelli, Maura; Calméjane, Marie-Ange; Lappartient, Emmanuelle; Ruff, Evelyne; Saada, Stéphanie; Holmes, Allyson; Bellet, Dominique; Sastre-Garau, Xavier
2016-10-01
Specific human papillomavirus genotypes are associated with most ano-genital carcinomas and a large subset of oro-pharyngeal carcinomas. Human papillomavirus DNA is thus a tumour marker that can be detected in the blood of patients for clinical monitoring. However, data concerning circulating human papillomavirus DNA in cervical cancer patients has provided little clinical value, due to insufficient sensitivity of the assays used for the detection of small sized tumours. Here we took advantage of the sensitive droplet digital PCR method to identify circulating human papillomavirus DNA in patients with human papillomavirus-associated carcinomas. A series of 70 serum specimens, taken at the time of diagnosis, between 2002 and 2013, were retrospectively analyzed in patients with human papillomavirus-16 or human papillomavirus-18-associated carcinomas, composed of 47 cases from the uterine cervix, 15 from the anal canal and 8 from the oro-pharynx. As negative controls, 18 serum samples from women with human papillomavirus-16-associated high-grade cervical intraepithelial neoplasia were also analyzed. Serum samples were stored at -80°C (27 cases) or at -20°C (43 cases). DNA was isolated from 200 µl of serum or plasma and droplet digital PCR was performed using human papillomavirus-16 E7 and human papillomavirus-18 E7 specific primers. Circulating human papillomavirus DNA was detected in 61/70 (87%) serum samples from patients with carcinoma and in no serum from patients with cervical intraepithelial neoplasia. The positivity rate increased to 93% when using only serum stored at -80°C. Importantly, the two patients with microinvasive carcinomas in this series were positive. Quantitative evaluation showed that circulating viral DNA levels in cervical cancer patients were related to the clinical stage and tumour size, ranging from 55 ± 85 copies/ml (stage I) to 1774 ± 3676 copies/ml (stage IV). Circulating human papillomavirus DNA is present in patients with human papillomavirus-associated invasive cancers even at sub-clinical stages and its level is related to tumour dynamics. Droplet digital PCR is a promising method for circulating human papillomavirus DNA detection and quantification. No positivity was found in patients with human papillomavirus-associated high grade cervical intraepithelial neoplasia.
Jeannot, Emmanuelle; Becette, Véronique; Campitelli, Maura; Calméjane, Marie‐Ange; Lappartient, Emmanuelle; Ruff, Evelyne; Saada, Stéphanie; Holmes, Allyson; Bellet, Dominique
2016-01-01
Abstract Specific human papillomavirus genotypes are associated with most ano‐genital carcinomas and a large subset of oro‐pharyngeal carcinomas. Human papillomavirus DNA is thus a tumour marker that can be detected in the blood of patients for clinical monitoring. However, data concerning circulating human papillomavirus DNA in cervical cancer patients has provided little clinical value, due to insufficient sensitivity of the assays used for the detection of small sized tumours. Here we took advantage of the sensitive droplet digital PCR method to identify circulating human papillomavirus DNA in patients with human papillomavirus‐associated carcinomas. A series of 70 serum specimens, taken at the time of diagnosis, between 2002 and 2013, were retrospectively analyzed in patients with human papillomavirus‐16 or human papillomavirus‐18‐associated carcinomas, composed of 47 cases from the uterine cervix, 15 from the anal canal and 8 from the oro‐pharynx. As negative controls, 18 serum samples from women with human papillomavirus‐16‐associated high‐grade cervical intraepithelial neoplasia were also analyzed. Serum samples were stored at −80°C (27 cases) or at −20°C (43 cases). DNA was isolated from 200 µl of serum or plasma and droplet digital PCR was performed using human papillomavirus‐16 E7 and human papillomavirus‐18 E7 specific primers. Circulating human papillomavirus DNA was detected in 61/70 (87%) serum samples from patients with carcinoma and in no serum from patients with cervical intraepithelial neoplasia. The positivity rate increased to 93% when using only serum stored at −80°C. Importantly, the two patients with microinvasive carcinomas in this series were positive. Quantitative evaluation showed that circulating viral DNA levels in cervical cancer patients were related to the clinical stage and tumour size, ranging from 55 ± 85 copies/ml (stage I) to 1774 ± 3676 copies/ml (stage IV). Circulating human papillomavirus DNA is present in patients with human papillomavirus‐associated invasive cancers even at sub‐clinical stages and its level is related to tumour dynamics. Droplet digital PCR is a promising method for circulating human papillomavirus DNA detection and quantification. No positivity was found in patients with human papillomavirus‐associated high grade cervical intraepithelial neoplasia. PMID:27917295
Johnson, Casey; Monath, Thomas P; Kanesa-Thasan, Niranjan; Mathis, Danell; Miller, Chuck; Shapiro, Seth; Nichols, Richard; McCarthy, Karen; Deary, Alison; Bedford, Philip
2005-01-01
Two subjects developed marked elevations in creatine kinase and other serum enzymes associated with mild myalgia during a randomized, double-blind, controlled Phase 1 clinical trial of an investigational live, attenuated vaccine against West Nile virus (ChimeriVax-WN02). One subject had received ChimeriVax-WN02 while the other subject was enrolled in an active control group and received licensed yellow fever 17D vaccine (YF-VAX). Subsequently, the clinical trial was interrupted, and an investigation was begun to evaluate the enzyme abnormalities. As daily serum samples were collected for determination of quantitative viremia, it was possible to define the enzyme elevations with precision and to relate these elevations to physical activity of the subjects, symptoms, and virological and serological measurements. Evaluation of both subjects clearly showed that skeletal muscle injury, and not cardiac or hepatic dysfunction, was responsible for the biochemical abnormalities. This investigation also implicated strenuous exercise as the cause of the apparent muscle injury rather than the study vaccines. As a result of this experience, subjects engaged in future early-stage trials of these live, attenuated viral vaccines will be advised not to engage in contact sports or new or enhanced exercise regimens for which they are not trained or conditioned. The inclusion of placebo control arm (in lieu of or addition to an active vaccine control) will also be useful in differentiating causally related serum enzyme elevations.
Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert
2014-07-01
Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Nomura, Sarah Jo; Robien, Kim; Zota, Ami R
2017-04-01
Background: Leukocyte telomere length (LTL) is a biomarker of the aging process and is associated with the risk of chronic disease. Higher exposure to cadmium may be associated with shorter LTL, and adequate nutrient concentrations may be associated with longer LTL; however, the potential interaction between metals and nutrients on LTL has yet to be examined. Objectives: The objective of this study was to evaluate whether serum concentrations of vitamins and carotenoids were associated with LTL, and whether they modified the association between blood cadmium and LTL in the US NHANES (1999-2002). Methods: We evaluated cross-sectional associations between LTL and serum concentrations of vitamin A, γ-tocopherol, α-tocopherol, folate, and vitamin B-12 (1999-2002; n = 7458) and α-carotene, β-carotene, β-cryptoxanthin, lutein + zeaxanthin, and lycopene (2001-2002; n = 4018) in a nationally representative sample of US adults (≥20 y of age) with the use of multivariable linear regression. We further investigated whether vitamin and carotenoid concentrations modified associations between blood cadmium and LTL with models stratified by serum nutrient concentrations and the inclusion of an interaction term. Results: Blood cadmium was inversely associated with LTL (percentage of LTL difference per 1 μg/L = -3.74; 95% CI: -5.35, -2.10). Serum vitamin A was positively associated (percentage of LTL difference per 1 μg/L = 4.01; 95% CI: 0.26, 7.90) and γ-tocopherol was inversely associated (percentage of LTL difference per 1 μg/dL = -2.49; 95% CI: -4.21, -0.73) with LTL. Serum folate ( P -trend = 0.06) and α-tocopherol ( P -trend = 0.10) were marginally positively associated with LTL, whereas vitamin B-12 ( P -trend = 0.78) was not associated with LTL. Serum carotenoids were generally positively associated with LTL. Serum vitamin and carotenoid concentrations did not modify blood cadmium and LTL associations ( P -interaction > 0.10). Conclusions: Results from this cross-sectional study suggest that exposure to cadmium and certain nutrients may be associated with LTL in US adults, but the serum concentrations of the vitamins and carotenoids evaluated did not modify cross-sectional associations between cadmium exposure and LTL. © 2017 American Society for Nutrition.
2017-01-01
Background: Leukocyte telomere length (LTL) is a biomarker of the aging process and is associated with the risk of chronic disease. Higher exposure to cadmium may be associated with shorter LTL, and adequate nutrient concentrations may be associated with longer LTL; however, the potential interaction between metals and nutrients on LTL has yet to be examined. Objectives: The objective of this study was to evaluate whether serum concentrations of vitamins and carotenoids were associated with LTL, and whether they modified the association between blood cadmium and LTL in the US NHANES (1999–2002). Methods: We evaluated cross-sectional associations between LTL and serum concentrations of vitamin A, γ-tocopherol, α-tocopherol, folate, and vitamin B-12 (1999–2002; n = 7458) and α-carotene, β-carotene, β-cryptoxanthin, lutein + zeaxanthin, and lycopene (2001–2002; n = 4018) in a nationally representative sample of US adults (≥20 y of age) with the use of multivariable linear regression. We further investigated whether vitamin and carotenoid concentrations modified associations between blood cadmium and LTL with models stratified by serum nutrient concentrations and the inclusion of an interaction term. Results: Blood cadmium was inversely associated with LTL (percentage of LTL difference per 1 μg/L = −3.74; 95% CI: −5.35, −2.10). Serum vitamin A was positively associated (percentage of LTL difference per 1 μg/L = 4.01; 95% CI: 0.26, 7.90) and γ-tocopherol was inversely associated (percentage of LTL difference per 1 μg/dL = −2.49; 95% CI: −4.21, −0.73) with LTL. Serum folate (P-trend = 0.06) and α-tocopherol (P-trend = 0.10) were marginally positively associated with LTL, whereas vitamin B-12 (P-trend = 0.78) was not associated with LTL. Serum carotenoids were generally positively associated with LTL. Serum vitamin and carotenoid concentrations did not modify blood cadmium and LTL associations (P-interaction > 0.10). Conclusions: Results from this cross-sectional study suggest that exposure to cadmium and certain nutrients may be associated with LTL in US adults, but the serum concentrations of the vitamins and carotenoids evaluated did not modify cross-sectional associations between cadmium exposure and LTL. PMID:28275103
Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils
2014-01-01
Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.
Rollin, E; Berghaus, R D; Rapnicki, P; Godden, S M; Overton, M W
2010-03-01
The objective of this study was to determine the effect of an injection of 10% butaphosphan and cyanocobalamin (Catosal, Bayer, Shawnee Mission, KS) on the day of calving and 1 d later on the prevalence of subclinical ketosis in dairy cattle in the early postpartum period. Cows from 4 herds (n=1,122) were randomized to receive either 25mL of 10% butaphosphan and cyanocobalamin or 25mL of sterile water subcutaneously on both days. Each milliliter of Catosal contained 0.05mg of cyanocobalamin and 100mg of butaphosphan, which provided 17.3mg of P in the form of [1-(butylamino)-1-methylethyl]-phosphonic acid. Serum was sampled for beta-hydroxybutyrate (BHBA) concentration at calving (pretreatment) and again between 3 and 10 d in milk. A subset of samples from mature cows was also evaluated for serum Ca and P concentrations. When cows from all age groups were included in the analysis, there was no difference between the median serum BHBA concentrations of cows in the 2 treatment groups, and no difference in the proportion of hyperketonemic cows (serum BHBA >or=1,200micromol/L) during the first week postpartum. When the analysis was restricted to mature cows (lactation >or=3), both the median BHBA concentration and the proportion of hyperketonemic cows were significantly lower in the treatment group than in the placebo group. Serum Ca and P concentrations did not differ between treatment groups. Our results suggest that injection of butaphosphan and cyanocobalamin on the day of calving and 1 d later may decrease the prevalence of subclinical ketosis during the week after calving in mature dairy cows, but not in first- and second-lactation animals.
Berghoff, Martin; Hochberg, Alexandra; Schmid, Andreas; Schlegel, Jutta; Karrasch, Thomas; Kaps, Manfred; Schäffler, Andreas
2016-01-01
Adipokines bearing the potential to cross the blood-brain barrier (BBB) are promising candidates for the endocrine regulation of central nervous processes and of a postulated fat-brain axis. Resistin and progranulin concentrations in paired serum and cerebrospinal fluid (CSF) samples of patients undergoing neurological evaluation and spinal puncture were investigated. Samples of n = 270 consecutive patients with various neurological diseases were collected without prior selection. Adipokine serum and CSF concentrations were measured by enzyme-linked immunosorbent assay and serum and CSF routine parameters by standard procedures. Anthropometric data, medication and patient history were available. Serum levels of resistin and progranulin were positively correlated among each other, with respective CSF levels, low-density lipoprotein cholesterol levels and markers of systemic inflammation. CSF resistin concentrations were generally low. Progranulin CSF concentrations and CSF/serum progranulin ratio were significantly higher in patients with infectious diseases, with disturbed BBB function and with elevated CSF cell count and presence of oligoclonal bands. Both adipokines are able to cross the BBB depending on a differing patency that increases with increasing grade of barrier dysfunction. Whereas resistin represents a systemic marker of inflammation, CSF progranulin levels strongly depend on the underlying disease and dysfunction of blood-CSF barrier. Resistin and progranulin represent novel and putative regulators of the fat-brain axis by their ability to cross the BBB under physiological and pathophysiological conditions. The presented data provide insight into the characteristics of BBB function regarding progranulin and resistin and the basis for future establishment of normal values for CSF concentrations and CSF/serum ratios. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.
Lindström, Mikael; Tohmola, Niina; Renkonen, Risto; Hämäläinen, Esa; Schalin-Jäntti, Camilla; Itkonen, Outi
2018-07-01
Serotonin (5-hydroxytyramine) is a mediator of gastrointestinal smooth muscle contraction, and is secreted by neuroendocrine neoplasms (NENs). We developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for serum serotonin to be used in NEN diagnostics and follow-up. We used serum samples from healthy volunteers (n = 31) and patients suspected or monitored for NEN (n = 98). Serotonin-D 4 internal standard was added to samples before solid phase extraction (SPE) and quantification by LC-MS/MS. The effects of sample handling and preparation on serotonin stability were studied. Finally, we established a provisional reference range for serum serotonin and compared our assay with serum 5-hydroxyindoleacetic acid (5-HIAA) for detection of NENs. Our assay is sensitive and has a wide linear range (10-10,000 nmol/l). Serum serotonin is stable for 7 days at room temperature and for 3 months at -20 °C. Sampling temperature is not critical. Normal range for serum serotonin was 270-1490 nmol/l. We found that serum serotonin and 5-HIAA performed equally well as diagnostic tests for NENs. Our LC-MS/MS assay for serum serotonin is well suited for clinical research and patient diagnostics. Our results confirm that it can complement 5-HIAA in diagnosis of NENs. Copyright © 2018 Elsevier B.V. All rights reserved.
Gharbi, Sedigheh; Shamsara, Mehdi; Khateri, Shahriar; Soroush, Mohammad Reza; Ghorbanmehr, Nassim; Tavallaei, Mahmood; Nourani, Mohammad Reza; Mowla, Seyed Javad
2015-01-01
In spite of accumulating information about pathological aspects of sulfur mustard (SM), the precise mechanism responsible for its effects is not well understood. Circulating microRNAs (miRNAs) are promising biomarkers for disease diagnosis and prognosis. Accurate normalization using appropriate reference genes, is a critical step in miRNA expression studies. In this study, we aimed to identify appropriate reference gene for microRNA quantification in serum samples of SM victims. In this case and control experimental study, using quantitative real-time polymerase chain reaction (qRT-PCR), we evaluated the suitability of a panel of small RNAs including SNORD38B, SNORD49A, U6, 5S rRNA, miR-423-3p, miR-191, miR-16 and miR-103 in sera of 28 SM-exposed veterans of Iran-Iraq war (1980-1988) and 15 matched control volunteers. Different statistical algorithms including geNorm, Normfinder, best-keeper and comparative delta-quantification cycle (Cq) method were employed to find the least variable reference gene. miR-423-3p was identified as the most stably expressed reference gene, and miR- 103 and miR-16 ranked after that. We demonstrate that non-miRNA reference genes have the least stabil- ity in serum samples and that some house-keeping miRNAs may be used as more reliable reference genes for miRNAs in serum. In addition, using the geometric mean of two reference genes could increase the reliability of the normalizers.
Mohri, Mehrdad; Ehsani, Abdollah; Norouzian, M A; Bami, Mohammad Heidarpour; Seifi, Hesam A
2011-03-01
Most regions in Iran are generally selenium (Se) deficient and all mineral premixes which used in farm animals contain Se in the form of sodium selenite. The objective of this study was to evaluate the effects of injected Se and vitamin E (vit E) on hematology, serum proteins, and performance of lambs during the period which the animals are at risk of Se and/or vit E deficiency. The study also aims to determine the relationship between selenium injection and the levels of other trace elements in blood serum of lambs. A total of 16 lambs of Baloochi breed (age, 70 ± 7 days and weight, 15.2 ± 1.4) were enrolled in the study. The animals were divided into two groups. In the test group, vit E and Se injected at a dose of 0.2 ml/kg BW (Vetoquinol, Selepherol®, Lure Cedex, France, α-tocopherol acetate 3.82 g/100 ml plus sodium selenite 0.023 g/100 ml) at the enrollment. Control lambs were received equal amounts of normal saline as placebo. Blood was sampled from the jugular vein at the beginning of the study (enrollment, before injection of vit E and selenium and saline) and at days 7, 14, 21, and 28 of experiment. The amounts of total serum protein, albumin, glucose, iron, copper, zinc, creatine kinase (CK), and aspartate aminotransferase (AST) and Se were measured. The concentration of globulin was calculated as the difference between total serum protein and albumin. For evaluation of growth and health, body weight of all the lambs was measured at day 0 of the experiment and the sampling times and days of treatment for each lamb were recorded. Treatment with Se and vit E decreased the activities of CK and AST compared to the controls (p < 0.05). Age (sampling time) had significant effects on the values of Se, iron, zinc, AST, hemoglobin, total protein, glucose, weight, height, and length (p < 0.05). Significant interactions between sampling time and group were seen for CK, AST, iron, glucose, weight, and length. No significant differences were seen for total weight gain (control, 3.48 ± 0.75 kg; test, 3.85 ± 0.9 kg), and average daily gain (control, 0.12 ± 0.03 kg; test, 0.14 ± 0.03 kg) between trial groups.
Knauf, Sascha; Dahlmann, Franziska; Batamuzi, Emmanuel K; Frischmann, Sieghard; Liu, Hsi
2015-03-01
There is evidence to suggest that the yaws bacterium (Treponema pallidum ssp. pertenue) may exist in non-human primate populations residing in regions where yaws is endemic in humans. Especially in light of the fact that the World Health Organizaiton (WHO) recently launched its second yaws eradication campaign, there is a considerable need for reliable tools to identify treponemal infection in our closest relatives, African monkeys and great apes. It was hypothesized that commercially available serological tests detect simian anti-T. pallidum antibody in serum samples of baboons, with comparable sensitivity and specificity to their results on human sera. Test performances of five different treponemal tests (TTs) and two non-treponemal tests (NTTs) were evaluated using serum samples of 57 naturally T. pallidum-infected olive baboons (Papio anubis) from Lake Manyara National Park in Tanzania. The T. pallidum particle agglutination assay (TP-PA) was used as a gold standard for comparison. In addition, the overall infection status of the animals was used to further validate test performances. For most accurate results, only samples that originated from baboons of known infection status, as verified in a previous study by clinical inspection, PCR and immunohistochemistry, were included. All tests, TTs and NTTs, used in this study were able to reliably detect antibodies against T. pallidum in serum samples of infected baboons. The sensitivity of TTs ranged from 97.7-100%, while specificity was between 88.0-100.0%. The two NTTs detected anti-lipoidal antibodies in serum samples of infected baboons with a sensitivity of 83.3% whereas specificity was 100%. For screening purposes, the TT Espline TP provided the highest sensitivity and specificity and at the same time provided the most suitable format for use in the field. The enzyme immune assay Mastblot TP (IgG), however, could be considered as a confirmatory test.
Simple, miniaturized blood plasma extraction method.
Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E
2013-12-03
A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to that observed with serum samples obtained by venipuncture.
Evaluation of a CLEIA automated assay system for the detection of a panel of tumor markers.
Falzarano, Renato; Viggiani, Valentina; Michienzi, Simona; Longo, Flavia; Tudini, Silvestra; Frati, Luigi; Anastasi, Emanuela
2013-10-01
Tumor markers are commonly used to detect a relapse of disease in oncologic patients during follow-up. It is important to evaluate new assay systems for a better and more precise assessment, as a standardized method is currently lacking. The aim of this study was to assess the concordance between an automated chemiluminescent enzyme immunoassay system (LUMIPULSE® G1200) and our reference methods using seven tumor markers. Serum samples from 787 subjects representing a variety of diagnoses, including oncologic, were analyzed using LUMIPULSE® G1200 and our reference methods. Serum values were measured for the following analytes: prostate-specific antigen (PSA), alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), carbohydrate antigen 15-3 (CA15-3), carbohydrate antigen 19-9 (CA19-9), and cytokeratin 19 fragment (CYFRA 21-1). For the determination of CEA, AFP, and PSA, an automatic analyzer based on chemiluminescence was applied as reference method. To assess CYFRA 21-1, CA125, CA19-9, and CA15-3, an immunoradiometric manual system was employed. Method comparison by Passing-Bablok analysis resulted in slopes ranging from 0.9728 to 1.9089 and correlation coefficients from 0.9977 to 0.9335. The precision of each assay was assessed by testing six serum samples. Each sample was analyzed for all tumor biomarkers in duplicate and in three different runs. The coefficients of variation were less than 6.3 and 6.2 % for within-run and between-run variation, respectively. Our data suggest an overall good interassay agreement for all markers. The comparison with our reference methods showed good precision and reliability, highlighting its usefulness in clinical laboratory's routine.
Cadamuro, Janne; Mrazek, Cornelia; Leichtle, Alexander B.; Kipman, Ulrike; Felder, Thomas K.; Wiedemann, Helmut; Oberkofler, Hannes; Fiedler, Georg M.; Haschke-Becher, Elisabeth
2017-01-01
Introduction Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. Materials and methods We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. Results High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to < 0.001) and lower bicarbonate values (P = 0.049 to 0.008) in the latter. Conclusions Serum and heparin samples may be centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed. PMID:29187797
Cadamuro, Janne; Mrazek, Cornelia; Leichtle, Alexander B; Kipman, Ulrike; Felder, Thomas K; Wiedemann, Helmut; Oberkofler, Hannes; Fiedler, Georg M; Haschke-Becher, Elisabeth
2018-02-15
Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to < 0.001) and lower bicarbonate values (P = 0.049 to 0.008) in the latter. Serum and heparin samples may be centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed.
Vitamin D deficiency and insufficiency among patients with prostate cancer
Trump, Donald L.; Chadha, Manpreet K.; Sunga, Annette Y.; Fakih, Marwan G.; Ashraf, Umeer; Silliman, Carrie G.; Hollis, Bruce W.; Nesline, Mary K.; Tian, Lili; Tan, Wei; Johnson, Candace S.
2009-01-01
Objective To assess the frequency of vitamin D deficiency among men with prostate cancer, as considerable epidemiological, in vitro, in vivo and clinical data support an association between vitamin D deficiency and prostate cancer outcome. Patients, subjects and methods The study included 120 ambulatory men with recurrent prostate cancer and 50 with clinically localized prostate cancer who were evaluated and serum samples assayed for 25-OH vitamin D levels. Then 100 controls (both sexes), matched for age and season of serum sample, were chosen from a prospective serum banking protocol. The relationship between age, body mass index, disease stage, Eastern Cooperative Oncology Group performance status, season and previous therapy on vitamin D status were evaluated using univariate and multivariate analyses. Results The mean 25-OH vitamin D level was 25.9 ng/mL in those with recurrent disease, 27.5 ng/mL in men with clinically localized prostate cancer and 24.5 ng/mL in controls. The frequency of vitamin D deficiency (< 20 ng/mL) and insufficiency (20–31 ng/mL) was 40% and 32% in men with recurrent prostate; 28% had vitamin D levels that were normal (32–100 ng/mL). Among men with localized prostate cancer, 18% were deficient, 50% were insufficient and 32% were normal. Among controls, 31% were deficient, 40% were insufficient and 29% were normal. Metastatic disease (P = 0.005) and season of blood sampling (winter/spring; P = 0.01) were associated with vitamin D deficiency in patients with prostate cancer, while age, race, performance status and body mass index were not. Conclusions Vitamin D deficiency and insufficiency were common among men with prostate cancer and apparently normal controls in the western New York region. PMID:19426195
Vitamin D deficiency and insufficiency among patients with prostate cancer.
Trump, Donald L; Chadha, Manpreet K; Sunga, Annette Y; Fakih, Marwan G; Ashraf, Umeer; Silliman, Carrie G; Hollis, Bruce W; Nesline, Mary K; Tian, Lili; Tan, Wei; Johnson, Candace S
2009-10-01
To assess the frequency of vitamin D deficiency among men with prostate cancer, as considerable epidemiological, in vitro, in vivo and clinical data support an association between vitamin D deficiency and prostate cancer outcome. The study included 120 ambulatory men with recurrent prostate cancer and 50 with clinically localized prostate cancer who were evaluated and serum samples assayed for 25-OH vitamin D levels. Then 100 controls (both sexes), matched for age and season of serum sample, were chosen from a prospective serum banking protocol. The relationship between age, body mass index, disease stage, Eastern Cooperative Oncology Group performance status, season and previous therapy on vitamin D status were evaluated using univariate and multivariate analyses. The mean 25-OH vitamin D level was 25.9 ng/mL in those with recurrent disease, 27.5 ng/mL in men with clinically localized prostate cancer and 24.5 ng/mL in controls. The frequency of vitamin D deficiency (<20 ng/mL) and insufficiency (20-31 ng/mL) was 40% and 32% in men with recurrent prostate; 28% had vitamin D levels that were normal (32-100 ng/mL). Among men with localized prostate cancer, 18% were deficient, 50% were insufficient and 32% were normal. Among controls, 31% were deficient, 40% were insufficient and 29% were normal. Metastatic disease (P = 0.005) and season of blood sampling (winter/spring; P = 0.01) were associated with vitamin D deficiency in patients with prostate cancer, while age, race, performance status and body mass index were not. Vitamin D deficiency and insufficiency were common among men with prostate cancer and apparently normal controls in the western New York region.
Lead, cadmium and other metals in serum of pet dogs from an urban area of NW Poland.
Tomza-Marciniak, Agnieszka; Pilarczyk, Bogumiła; Bąkowska, Małgorzata; Ligocki, Marek; Gaik, Marcelina
2012-12-01
This study was designed to evaluate the degree of exposure of pet dogs from an urban area of NW Poland to selected metals, including toxic Cd and Pb. The study was conducted on a group of 48 healthy dogs. The serum concentration of the analysed elements followed the order Fe > Al > Zn > Cu > Mn > As > Sr > Pb > Cd > Cr > Ni > V. The presence of cadmium and lead was found in all the serum samples tested. The average contents of these elements were 0.309 and 0.489 μg/mL. The factors that played the greatest role in the intake of the analysed elements were diet and breed-dependent size of dogs. Small-sized dogs had higher concentrations of all elements compared with large dogs, with statistically significant differences noted for Cu, Pb, Cd and Sr. It was also found that dogs receiving commercial and mixed food had more metals in serum compared with dogs on homemade food (except strontium). The present study showed elevated concentrations of some heavy metals (Pb, Cd, Fe and Cu) in serum of pet dogs, which is probably due to the excess elemental load of this area. Given that no information is available on the concentrations of strontium, vanadium and aluminium in dogs, further research is necessary to determine certain reference values which would allow for an easier interpretation of results and evaluation of exposure to these elements.
Sprauten, Mette; Darrah, Thomas H.; Peterson, Derick R.; Campbell, M. Ellen; Hannigan, Robyn E.; Cvancarova, Milada; Beard, Clair; Haugnes, Hege S.; Fosså, Sophie D.; Oldenburg, Jan; Travis, Lois B.
2012-01-01
Purpose Cisplatin-induced neurotoxicity and ototoxicity (NTX) are important adverse effects after chemotherapy for testicular cancer (TC). Although serum platinum is measurable years after therapy, its impact on NTX has not been evaluated. Patients and Methods In all, 169 cisplatin-treated survivors of TC provided blood samples at Survey I and reported NTX during Survey I (1998-2002) and Survey II (2007-2008). Serum platinum was quantified by inductively coupled plasma mass spectrometry. Patient-reported outcomes were evaluated with the Scale for Chemotherapy-Induced Neurotoxicity (SCIN), regarding the extent of symptom bother as 0, “not at all”; 1, “a little”; 2, “quite a bit”; or 3, “very much.” Summing the six symptom scores yielded a total SCIN score of 0 to 18. Categorizing total SCIN scores into quartiles yielded similar-sized groups with increasing symptoms. Multivariate ordinal logistic regression analyses evaluated associations between NTX and long-term serum platinum levels, adjusting for cisplatin dose, dosing schedule, and age. Results At Survey I, a significant four- to five-fold association with total SCIN score emerged for the highest serum platinum quartile (odds ratio [OR], 4.69; 95% CI, 1.82 to 12.08). Paresthesias and Raynaud's syndrome (hands and feet) showed significant two- to four-fold increased risks with the highest platinum quartile. At Survey II, total SCIN score remained significantly associated with the highest platinum quartile (OR, 4.28; 95% CI, 1.36 to 13.48). Paresthesias (hands and feet) and tinnitus showed significant three- to four-fold increased risks for the highest platinum quartile. Cumulative cisplatin dose was not associated with total SCIN score or individual SCIN symptoms in multivariate analyses. Conclusion Here we document a significant relationship between increasing levels of residual serum platinum and NTX severity after adjusting for initial cisplatin dose. PMID:22184390
Bentley, Amy R.; Chen, Guanjie; Shriner, Daniel; Doumatey, Ayo P.; Zhou, Jie; Huang, Hanxia; Mullikin, James C.; Blakesley, Robert W.; Hansen, Nancy F.; Bouffard, Gerard G.; Cherukuri, Praveen F.; Maskeri, Baishali; Young, Alice C.; Adeyemo, Adebowale; Rotimi, Charles N.
2014-01-01
Although a considerable proportion of serum lipids loci identified in European ancestry individuals (EA) replicate in African Americans (AA), interethnic differences in the distribution of serum lipids suggest that some genetic determinants differ by ethnicity. We conducted a comprehensive evaluation of five lipid candidate genes to identify variants with ethnicity-specific effects. We sequenced ABCA1, LCAT, LPL, PON1, and SERPINE1 in 48 AA individuals with extreme serum lipid concentrations (high HDLC/low TG or low HDLC/high TG). Identified variants were genotyped in the full population-based sample of AA (n = 1694) and tested for an association with serum lipids. rs328 (LPL) and correlated variants were associated with higher HDLC and lower TG. Interestingly, a stronger effect was observed on a “European” vs. “African” genetic background at this locus. To investigate this effect, we evaluated the region among West Africans (WA). For TG, the effect size among WA was the same in AA with only African local ancestry (2–3% lower TG), while the larger association among AA with local European ancestry matched previous reports in EA (10%). For HDLC, there was no association with rs328 in AA with only African local ancestry or in WA, while the association among AA with European local ancestry was much greater than what has been observed for EA (15 vs. ∼5 mg/dl), suggesting an interaction with an environmental or genetic factor that differs by ethnicity. Beyond this ancestry effect, the importance of African ancestry-focused, sequence-based work was also highlighted by serum lipid associations of variants that were in higher frequency (or present only) among those of African ancestry. By beginning our study with the sequence variation present in AA individuals, investigating local ancestry effects, and seeking replication in WA, we were able to comprehensively evaluate the role of a set of candidate genes in serum lipids in AA. PMID:24603370
Lamglait, Benjamin; Vandenbunder-Beltrame, Marielle
2017-09-01
Symmetric dimethylarginine (SDMA) has been shown to be a valuable biomarker for early detection of chronic kidney disease (CKD) in canine and feline patients. Recognition of early (subclinical) kidney disease would be of value in cheetahs (Acinonyx jubatus) as prevalence of CKD is relatively high in this species in captivity. Fifty-eight banked serum and plasma samples from seven adult cheetahs that died of CKD were analyzed for creatinine, urea, and SDMA. A marked increase in SDMA was noted on five of the tested cheetahs earlier than the rise of serum creatinine and urea (estimated 8-35 mo; mean 21.4 mo; median 22 mo). SDMA appears as an early biomarker to evaluate renal function for the diagnosis of CKD in cheetahs regardless of the cause of this disease.
Lv, Zhuangwei; Liu, Min; Shen, Jinghui; Xiang, Dong; Ma, Yunfeng; Ji, Yanhong
2018-01-01
Interleukin-10 (IL-10), interleukin-17A (IL-17A) and transforming growth factor α (TGF-α) have been implicated in the progression of breast cancer. However, the diagnostic and prognostic roles of these cytokines in ductal carcinoma remain unclear. The present study therefore aimed to determine the serum levels of IL-10, IL-17 and TGF-α in subjects with benign and malignant breast diseases and to evaluate the clinical significance of these cytokines in ductal carcinoma. Pre-operative serum samples were collected from 378 patients with breast disease and 70 healthy subjects. IL-10, IL-17A and TGF-α levels were measured using ELISA. Serum levels of these cytokine in patients with different breast diseases were evaluated. Furthermore, correlations between levels of these cytokines and the expression of estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER2) in ductal carcinoma were determined. The results demonstrated that serum levels of IL-10 and IL-17A were significantly increased in subjects with atypical hyperplasia and ductal carcinoma. Furthermore, IL-10 and IL-17A levels were increased in patients with a more serious clinical tumor stage and tumors that were ER− and PR−. Furthermore, high serum levels of TGF-α were associated with HER2+ tumors. A strong positive correlation was identified between TGF-α and IL-17A levels. Therefore, the results of the current study revealed that elevated serum IL-10, IL-17A and TGF-α levels are strongly associated with ductal carcinoma, specifically with tumor stage. High serum levels of IL-10 and IL-17A were also associated with the negative expression of ER and PR in ductal carcinoma, and high serum levels of TGF-α were associated with the positive expression of HER2 in ductal carcinoma. Thus, serum cytokine levels may be measured to identify patients with a poor prognosis who may benefit from more aggressive management and treatment. PMID:29904427
Lv, Zhuangwei; Liu, Min; Shen, Jinghui; Xiang, Dong; Ma, Yunfeng; Ji, Yanhong
2018-06-01
Interleukin-10 (IL-10), interleukin-17A (IL-17A) and transforming growth factor α (TGF-α) have been implicated in the progression of breast cancer. However, the diagnostic and prognostic roles of these cytokines in ductal carcinoma remain unclear. The present study therefore aimed to determine the serum levels of IL-10, IL-17 and TGF-α in subjects with benign and malignant breast diseases and to evaluate the clinical significance of these cytokines in ductal carcinoma. Pre-operative serum samples were collected from 378 patients with breast disease and 70 healthy subjects. IL-10, IL-17A and TGF-α levels were measured using ELISA. Serum levels of these cytokine in patients with different breast diseases were evaluated. Furthermore, correlations between levels of these cytokines and the expression of estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER2) in ductal carcinoma were determined. The results demonstrated that serum levels of IL-10 and IL-17A were significantly increased in subjects with atypical hyperplasia and ductal carcinoma. Furthermore, IL-10 and IL-17A levels were increased in patients with a more serious clinical tumor stage and tumors that were ER - and PR - . Furthermore, high serum levels of TGF-α were associated with HER2 + tumors. A strong positive correlation was identified between TGF-α and IL-17A levels. Therefore, the results of the current study revealed that elevated serum IL-10, IL-17A and TGF-α levels are strongly associated with ductal carcinoma, specifically with tumor stage. High serum levels of IL-10 and IL-17A were also associated with the negative expression of ER and PR in ductal carcinoma, and high serum levels of TGF-α were associated with the positive expression of HER2 in ductal carcinoma. Thus, serum cytokine levels may be measured to identify patients with a poor prognosis who may benefit from more aggressive management and treatment.
Heilmann, Romy M; Grützner, Niels; Thames, Brittany E; Steiner, Jörg M; Barr, James W
2017-11-01
To determine whether the concentration of serum canine alpha 1 -proteinase inhibitor (cα 1 -PI) has diagnostic or prognostic utility in dogs with sepsis or noninfectious systemic inflammatory response syndrome (SIRS). Prospective, observational study from May to December 2010. University teaching hospital ICU. Sixty-nine client-owned dogs: 19 dogs with SIRS or sepsis and 50 healthy control dogs. None. Serum and plasma samples were collected from dogs with SIRS or sepsis on the day of hospital admission and once on the following 2 days, and on a single day in healthy controls. Patients were assessed using the 10-parameter Acute Patient Physiologic and Laboratory Evaluation (APPLE full ) and 5-parameter (APPLE fast ) score. Serum cα 1 -PI concentrations were measured, compared among groups of dogs, and evaluated for a correlation with the concentration of serum C-reactive protein, plasma interleukin-6, tumor necrosis factor-α, the APPLE scores, and survival to discharge. Serum cα 1 -PI concentrations were significantly lower in dogs with SIRS/sepsis (P < 0.001) than in healthy controls. While day 1 serum cα 1 -PI concentrations did not differ between dogs with SIRS and those with sepsis (P = 0.592), septic dogs had significantly lower serum cα 1 -PI concentrations on days 2 (P = 0.017) and 3 (P = 0.036) than dogs with SIRS. Serum cα 1 -PI concentrations did not differ between survivors and nonsurvivors (P = 1.000), but were inversely correlated with the APPLE full score (ρ = -0.48; P = 0.040) and plasma interleukin-6 concentrations (ρ = -0.50; P = 0.037). These results suggest a role of cα 1 -PI as a negative acute phase protein in dogs. The concentration of serum cα 1 -PI at the time of hospital admission does not have utility to identify dogs with sepsis from those with noninfectious SIRS, but may be a useful surrogate marker for early stratification of illness severity. © Veterinary Emergency and Critical Care Society 2017.
Watkins, Paul B
2018-04-26
The study by Mason et al. in this issue used mechanistic modeling and simulation to address how both the dose of acetaminophen consumed and the time since ingestion can be estimated from biomarkers measured in a single serum sample in mice. Translation into the clinic would potentially be an advance in the treatment of acetaminophen poisoning. Importantly, this approach could transform the evaluation of liver safety in clinical trials of new drug candidates. © 2018 The Authors CPT: Pharmacometrics & Systems Pharmacology published by Wiley Periodicals, Inc. on behalf of American Society for Clinical Pharmacology and Therapeutics.
Quantitative bioanalysis of strontium in human serum by inductively coupled plasma-mass spectrometry
Somarouthu, Srikanth; Ohh, Jayoung; Shaked, Jonathan; Cunico, Robert L; Yakatan, Gerald; Corritori, Suzana; Tami, Joe; Foehr, Erik D
2015-01-01
Aim: A bioanalytical method using inductively-coupled plasma-mass spectrometry to measure endogenous levels of strontium in human serum was developed and validated. Results & methodology: This article details the experimental procedures used for the method development and validation thus demonstrating the application of the inductively-coupled plasma-mass spectrometry method for quantification of strontium in human serum samples. The assay was validated for specificity, linearity, accuracy, precision, recovery and stability. Significant endogenous levels of strontium are present in human serum samples ranging from 19 to 96 ng/ml with a mean of 34.6 ± 15.2 ng/ml (SD). Discussion & conclusion: Calibration procedures and sample pretreatment were simplified for high throughput analysis. The validation demonstrates that the method was sensitive, selective for quantification of strontium (88Sr) and is suitable for routine clinical testing of strontium in human serum samples. PMID:28031925
Evaluation of a handheld point-of-care analyser for measurement of creatinine in cats.
Reeve, Jenny; Warman, Sheena; Lewis, Daniel; Watson, Natalie; Papasouliotis, Kostas
2017-02-01
Objectives The aim of the study was to evaluate whether a handheld creatinine analyser (StatSensor Xpress; SSXp), available for human patients, can be used to measure creatinine reliably in cats. Methods Analytical performance was evaluated by determining within- and between-run coefficient of variation (CV, %), total error observed (TE obs , %) and sigma metrics. Fifty client-owned cats presenting for investigation of clinical disease had creatinine measured simultaneously, using SSXp (whole blood and plasma) and a reference instrument (Konelab, serum); 48 paired samples were included in the study. Creatinine correlation between methodologies (SSXp vs Konelab) and sample types (SSXp whole blood vs SSXp plasma ) was assessed by Spearman's correlation coefficient and agreement was determined using Bland-Altman difference plots. Each creatinine value was assigned an IRIS stage (1-4); correlation and agreement between Konelab and SSXp IRIS stages were evaluated. Results Within-run CV (4.23-8.85%), between-run CV (8.95-11.72%), TE obs (22.15-34.92%) and sigma metrics (⩽3) did not meet desired analytical requirements. Correlation between sample types was high (SSXp whole blood vs SSXp plasma ; r = 0.89), and between instruments was high (SSXp whole blood vs Konelab serum ; r = 0.85) to very high (SSXp plasma vs Konelab serum ; r = 0.91). Konelab and SSXp whole blood IRIS scores exhibited high correlation ( r = 0.76). Packed cell volume did not significantly affect SSXp determination of creatinine. Bland-Altman difference plots identified a positive bias for the SSXp (7.13 μmol/l SSXp whole blood ; 20.23 μmol/l SSXp plasma ) compared with the Konelab. Outliers (1/48 whole blood; 2/48 plasma) occurred exclusively at very high creatinine concentrations. The SSXp failed to identify 2/21 azotaemic cats. Conclusions and relevance Analytical performance of the SSXp in feline patients is not considered acceptable. The SSXp exhibited a high to very high correlation compared with the reference methodology but the two instruments cannot be used interchangeably. Improvements in the SSXp analytical performance are needed before its use can be recommended in feline clinical practice.
Feasibility study of feces for noninvasive biomonitoring of brominated flame retardants in toddlers.
Sahlström, Leena M O; Sellström, Ulla; de Wit, Cynthia A; Lignell, Sanna; Darnerud, Per Ola
2015-01-06
This study investigated the feasibility of using feces as a noninvasive matrix to estimate serum concentrations of brominated flame retardants (BFRs) in toddlers for biomonitoring purposes. Tri- to decabrominated diphenyl ethers (tri-decaBDEs), isomer-specific hexabromocyclododecanes, and 16 emerging BFRs were determined in feces from 22 toddlers (11-15 months of age), and results were compared to previously analyzed matched serum samples. BDE-47, -153, -196, -197, -203, -206, -207, -208, and -209 were detected in the feces creating a matched data set (feces-serum, n = 21). Tetra-octaBDE concentrations were significantly higher (Student's paired comparisons t test, α = 0.05) in serum versus feces with BDE-153 having the highest mean difference between the sample matrices. BDE-209 was found in significantly higher concentrations in feces compared to serum. Significant correlations (Pearson's, α = 0.05) between congener-specific concentrations in feces and serum were found for all BDEs except BDE-197 and -203. The feces-serum associations found can be used to estimate serum concentrations of tetra-decaBDEs from feces concentrations and enable a noninvasive sampling method for biomonitoring BDEs in toddlers.
Nyberg, G; Mårtensson, E
1986-01-01
The effects were tested of eight common types of blood collection tubes and two types of "plasma separators" on the stability of the tricyclic antidepressants amitriptyline, imipramine, clomipramine, and their monodemethylated metabolites in venous blood samples. Although EDTA-containing Venoject lavender and Vacutainer lavender tubes seemed to give the most stable plasma samples, and Venoject red the most stable serum samples, the differences were too small to have practical consequences. Vacutainer royal blue collection tubes gave significant losses of greater than 20% of some of the substances. The tubes with serum separator gel or filter proved unsuitable, since they were responsible for losses of greater than 40%. The losses were not caused by redistribution between blood cells and plasma but occurred mainly as a result of contact between the contents and the caps of the tubes. Experiments with freezing, thawing, and storage of samples showed that freshly sampled blood could be stored at room temperature for 24 h in Venoject green tubes without significant losses. Serum samples could be stored at refrigerator temperature for 4 weeks without important losses. Freezing, thawing, and storage at -20 degrees C did not influence the serum or plasma concentrations.
[HTLV-1 in a Mapuche population].
Inostroza, J; Díaz, P; Saunier, C
1990-12-01
The seroprevalence of HTLV-1 in 405 serum samples from South American Indians, Mapuches, from the IXth region of Chile was investigated using enzyme linked immunosorbent assay (ELISA). Six samples were positive and only 3 of them were also positive by western blot and radio immuno precipitation assay. This corresponds to a seroprevalence of 0.74% for HTLV-1 in healthy Mapuches, which differs from that observed in other populations throughout the world. Additional studies are necessary to evaluate the real magnitudes of HTLV-1 infection in Chile.
Martinez-Guzman, Marco Alonso; Alvarado-Navarro, Anabell; Delgado-Rizo, Vidal; Garcia-Orozco, Alejandra; Mayorga-Rodríguez, Jorge Arturo; Pereira-Suarez, Ana Laura; Fafutis-Morris, Mary
2018-01-01
Leprosy is a chronic disease caused by Mycobacterium leprae that affects the skin and peripheral nerves. It may present as one of two distinct poles: the self-limiting tuberculoid leprosy and the highly infectious lepromatous leprosy (LL) characterized by M. leprae-specific absence of cellular immune response. The pro-inflammatory cytokine macrophage migration inhibitory factor (MIF) enhance the bactericide activities of macrophages after interaction with its receptor, CD74. Importantly, MIF also possesses chemoattractant properties, and it is a key factor in situ for the activation of macrophages and in blood to promote leukocytes migration. MIF-mediated activation of macrophages is a key process for the elimination of pathogens such as Mycobacterium tuberculosis; however, its participation for the clearance of M. leprae is unclear. The aim of this study was to evaluate the serum levels of MIF as well as MIF and CD74 expression in skin lesions of LL and compare it with healthy skin (HSk) taken from subjects attending to dermatological consult. Samples of serum and skin biopsies were taken from 39 LL patients and compared with 36 serum samples of healthy subjects (HS) and 10 biopsies of HSk. Serum samples were analyzed by ELISA and skin biopsies by immunohistochemistry (IHC). IHC smears were observed in 12 100× microscopic fields, in which percentage of stained cells and staining intensity were evaluated. Both variables were used to calculate a semi-quantitative expression score that ranged from 0 to 3+. We found no differences in MIF levels between LL patients and HS in sera. In addition, MIF was observed in over 75% of cells with high intensity in the skin of patients and HSk. Although we found no differences in MIF expression between the groups, a CD74 score statistically higher was found in LL skin than HSk (p < 0.001); this was the result of a higher percentage of cells positive for CD74 (p < 0.001). As a conclusion, we found that CD74-positive cells are intensely recruited to the skin with LL lesions. In this manner, MIF signaling may be enhanced in the skin of LL patients due to increased expression of its receptor, but further studies are required. PMID:29487601
Zhang, Xiaolan; Li, Xiaojing; Jing, Ye; Fang, Xiangming; Zhang, Xinyu; Lei, Bingli; Yu, Yingxin
2017-03-01
Prenatal exposure to polycyclic aromatic hydrocarbons (PAHs) is a high-priority public health concern. However, maternal to fetal transplacental transfer of PAHs has not been systematically studied. To investigate the transplacental transfer of PAHs from mother to fetus and determine the influence of lipophilicity (octanol-water partition coefficient, K OW ) on transfer process, in the present study, we measured the concentrations of 15 PAHs in 95 paired maternal and umbilical cord serum, and placenta samples (in total 285 samples) collected in Shanghai, China. The average concentration of total PAHs was the highest in maternal serums (1290 ng g -1 lipid), followed by umbilical cord serums (1150 ng g -1 lipid). The value was the lowest in placenta samples (673 ng g -1 lipid). Low molecular weight PAHs were the predominant compounds in the three matrices. Increases in fish and meat consumption did not lead to increases in maternal PAH levels, and no obvious gender differences in umbilical cord serums were observed. The widespread presence of PAHs in umbilical cord serums indicated the occurrence of transplacental transfer. The ratios of PAH concentrations in umbilical cord serum to those in maternal serum (F/M) and the concentrations in placenta to those in maternal serum (P/M) of paired samples were analyzed to characterize the transfer process of individual PAHs. Most F/M ratios on lipid basis were close to one (range: 0.79 to 1.36), which suggested that passive diffusion may control the transplacental transfer of PAHs from maternal serum to the fetal circulation. The P/M and F/M values calculated on lipid basis showed that PAHs with lower K OW were more likely to transfer from mother to fetus via the placenta. Copyright © 2016 Elsevier Ltd. All rights reserved.
Riddell, Michaela A.; Byrnes, Graham B.; Leydon, Jennie A.; Kelly, Heath A.
2003-01-01
OBJECTIVES: To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay. METHODS: Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20. FINDINGS: DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing. CONCLUSION: These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus. PMID:14758429
Ali, Nadeem; Malik, Riffat Naseem; Mehdi, Toufeer; Eqani, Syed Ali Musstjab Akber Shah; Javeed, Aqeel; Neels, Hugo; Covaci, Adrian
2013-04-01
Concentrations of different classes of organohalogenated contaminants (OHCs) viz., polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), bromophenols (BPs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and their metabolites were determined in cat and dog serum and hair samples from Pakistan. The major DDT metabolite, p,p'-DDE, was the major OHC in cat serum (N=20) and ranged between 1 and 2150 ng/g lipid weight (lw). p,p'-DDE was not detected in dog serum (N=16). In contrary to other OHCs, levels of ∑HO-PCBs were significantly higher in dog serum (median=6.0 ng/g lw) than cat serum (median=2.2 ng/g lw). Levels of most OHCs were significantly higher (p<0.05) in cat serum than those found in human serum from the same region, in particular for ∑PBDEs (ranged 1-1280 ng/g lw). Significantly lower levels of OCPs (p<0.05) were detected in dog serum than in human serum. The concentrations of ∑BPs were seven times higher in cat serum (median 112 ng/g lw) than dog serum (median 16 ng/g lw). To the best of our knowledge, this is the first time that NBFRs, e.g. 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), decabromodiphenylethane (DBDPE), and bis(2-ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), were detected in cat and dog's hair. BTBPE had the highest detection frequency (30%) in the serum samples. In cat and dog hair samples, the order of importance of OHCs was ∑OCPs>∑NBFRs>∑PBDEs>∑PCB, with the highest concentrations being around 38 ng/g hair. In paired hair-serum cat samples (N=12), ∑DDTs (r=0.65, p=0.001) were significantly correlated, while for all other OHCs no significant correlations (p<0.001) were observed in both cats and dogs. Our findings on both hair and serum samples suggested that pet dogs do not bioaccumulate DDTs. Our results are also in agreement with the hypothesis that pets may serve as biosentinels for indoor pollution. This is the first study to document the presence of OHCs in pets from Pakistan and provides baseline information for future monitoring of OHCs in pets. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rotan, H.; Ginting, Y.; Loesnihari, R.; Kembaren, T.; Marpaung, B.
2018-03-01
Lyme borreliosis is the most common tick-borne disease, and frequency of arthritis complication later. The objective of this study was to determine the seroprevalence of Lyme disease and to evaluate its correlation with chronic arthritis. This epidemiologic cross sectional study included 41 healthy individuals who had chronic arthritis and bitten by ticks underwent questionnaires, and laboratory tests consisted of a routine blood sample, serum uric acid, and IgG ELISA for Lyme. There was 7.32% presence of positive IgG for Lyme. Samples with positive IgG for Lyme were further evaluated for rheumatology marker. We found three samples with a positive rheumatoid factor, two samples had positive anti-MCV, and 1 sample had slightly increased CRP. Three Lyme positive samples had normal EULAR scoring. It was the first Lyme disease case found in Indonesia, particularly in 4 villages of Sibolangit, Deli Serdang, North Sumatera. The assessment made by analysis the questionnaire, evaluation the blood test, and confirmed positive Lyme disease, and at last, we found the correlation between chronic arthritis with positive test Lyme.
Bobbo, T; Fiore, E; Gianesella, M; Morgante, M; Gallo, L; Ruegg, P L; Bittante, G; Cecchinato, A
2017-12-01
Blood serum proteins are significant indicators of animal health. Nevertheless, several factors should be considered to appropriately interpret their concentrations in blood. Therefore, the objectives of this study were (1) to assess the effect of herd productivity, breed, age and stage of lactation on serum proteins and (2) to investigate association between serum proteins and somatic cell count (SCC) in dairy cattle. Milk and blood samples were collected from 1508 cows of six different breeds (Holstein Friesian, Brown Swiss, Jersey, Simmental, Rendena and Alpine Grey) that were housed in 41 multi-breed herds. Milk samples were analyzed for composition and SCC, while blood samples were analyzed for serum proteins (i.e. total protein, albumin, globulin and albumin-to-globulin ratio (A : G)). Herds were classified as low or high production, according to the cow's average daily milk energy yield adjusted for breed, days in milk (DIM) and parity. Data were analyzed using a linear mixed model that included the fixed effects of DIM, parity, SCS, breed, herd productivity and the random effect of the Herd-test date within productivity level. Cows in high producing herds (characterized also by greater use of concentrates in the diet) had greater serum albumin concentrations. Breed differences were reported for all traits, highlighting a possible genetic mechanism. The specialized breed Jersey and the two dual-purpose local breeds (Alpine Grey and Rendena) had the lowest globulin concentration and greatest A : G. Changes in serum proteins were observed through lactation. Total protein reached the highest concentration during the 4th month of lactation. Blood albumin increased with DIM following a quadratic pattern, while globulin decreased linearly. As a consequence, A : G increased linearly during lactation. Older cows had greater total protein and globulin concentrations, while albumin concentration seemed to be not particularly affected by age. A linear relationship between serum proteins and SCS was observed. High milk SCS was associated with greater total protein and globulin concentrations in blood. The rise in globulin concentration, together with a decrease in albumin concentrations, resulted in a decline in A : G as SCS of milk increased. In conclusion, such non-genetic factors must be considered to appropriately interpret serum proteins as potential animal welfare indicator and their evaluation represents an important first-step for future analysis based on the integration of metabolomics, genetic and genomic information for improving the robustness of dairy cows.
Nelson, C D; Powell, J L; Price, D M; Hersom, M J; Yelich, J V; Drewnoski, M E; Bird, S L; Bridges, G Allen
2016-09-01
Vitamin D is critical for the growth and development of calves and positively contributes to immune function of cattle. Serum 25-hydroxyvitamin D (25(OH)D) concentrations above 20 ng/mL have traditionally been considered adequate for growth and development of cattle, but recent evidence has indicated that concentrations below 30 ng/mL are insufficient for immunity. Because little information is available regarding vitamin D status of beef cattle, the objective of this study was to evaluate vitamin D status of beef cow-calf herds on pasture as affected by season and location. Serum samples were collected from 43 cow-calf pairs plus an additional 54 calves in herds located in Florida, Idaho, and Minnesota in the spring calving season. Samples were collected again over the summer months from animals in the Florida and Minnesota herds. Effects of subcutaneous injection of vitamins A, D, and E also were investigated in a subset of calves from the Idaho herd. All cows sampled had serum 25(OH)D concentrations above 30 ng/mL at the time of calving in the spring. The average serum 25(OH)D concentrations of cows rose from near 60 ng/mL in the spring to 75 ng/mL in the summer ( < 0.001). Most calves, on the other hand, had serum 25(OH)D concentrations below 20 ng/mL. The calves in the Florida and Minnesota herds similarly rose from averages of 10 to 15 ng/mL at birth to near 50 ng/mL by the end of summer. Serum 25(OH)D of severely deficient calves increased from 3 ng/mL in nonsupplemented calves to 11 ng/mL at 48 h after birth if given a bolus supplementation of 40,000 IU of vitamin D via subcutaneous injection of a vitamin A, D, and E supplement at birth ( < 0.001). Vitamin D supplementation of cows late in pregnancy has been shown to increase serum 25(OH)D of calves; however, beef cattle generally receive very little supplemental vitamin D, as was the case for the cows studied here. The lower serum 25(OH)D of cows in spring compared with summer and the prevalence of vitamin D deficiency of calves observed here indicate that increased vitamin D supplementation of cows over the winter months or vitamin D supplementation of newborn calves would be beneficial.
Frías-De-León, María Guadalupe; Ramírez-Bárcenas, José Antonio; Rodríguez-Arellanes, Gabriela; Velasco-Castrejón, Oscar; Taylor, Maria Lucia; Reyes-Montes, María Del Rocío
2017-03-01
Histoplasmosis is considered the most important systemic mycosis in Mexico, and its diagnosis requires fast and reliable methodologies. The present study evaluated the usefulness of PCR using Hcp100 and 1281-1283 (220) molecular markers in detecting Histoplasma capsulatum in occupational and recreational outbreaks. Seven clinical serum samples of infected individuals from three different histoplasmosis outbreaks were processed by enzyme-linked immunosorbent assay (ELISA) to titre anti-H. capsulatum antibodies and to extract DNA. Fourteen environmental samples were also processed for H. capsulatum isolation and DNA extraction. Both clinical and environmental DNA samples were analysed by PCR with Hcp100 and 1281-1283 (220) markers. Antibodies to H. capsulatum were detected by ELISA in all serum samples using specific antigens, and in six of these samples, the PCR products of both molecular markers were amplified. Four environmental samples amplified one of the two markers, but only one sample amplified both markers and an isolate of H. capsulatum was cultured from this sample. All PCR products were sequenced, and the sequences for each marker were analysed using the Basic Local Alignment Search Tool (BLASTn), which revealed 95-98 and 98-100 % similarities with the reference sequences deposited in the GenBank for Hcp100 and 1281-1283 (220) , respectively. Both molecular markers proved to be useful in studying histoplasmosis outbreaks because they are matched for pathogen detection in either clinical or environmental samples.