1988-09-01
Test and Evaluation Report Test and Evaluation of the Navy Technical Information Presentation System (NTIPS) F-14A Field Test Results by .0 Joseph J...PROGRAM PROJECT TASK WORK UNIT Washington, D.C. 20361 ELEMENT NO. NO. NO. ACCESSION NO. OMN 1820 11. TITLE (Include Security Classification) TEST AND...EVALUATION OF THE NAVY TECHNICAL INFORMATION PRESENTATION SYSTEM (NTIPS) F-14A FIELD TEST RESULTS 12. PERSONAL AUTHOR(S) Fuller, Joseph F. (DTRC) Post
NASA Astrophysics Data System (ADS)
Hart, D. M.; Merchant, B. J.; Abbott, R. E.
2012-12-01
The Component Evaluation project at Sandia National Laboratories supports the Ground-based Nuclear Explosion Monitoring program by performing testing and evaluation of the components that are used in seismic and infrasound monitoring systems. In order to perform this work, Component Evaluation maintains a testing facility called the FACT (Facility for Acceptance, Calibration, and Testing) site, a variety of test bed equipment, and a suite of software tools for analyzing test data. Recently, Component Evaluation has successfully integrated several improvements to its software analysis tools and test bed equipment that have substantially improved our ability to test and evaluate components. The software tool that is used to analyze test data is called TALENT: Test and AnaLysis EvaluatioN Tool. TALENT is designed to be a single, standard interface to all test configuration, metadata, parameters, waveforms, and results that are generated in the course of testing monitoring systems. It provides traceability by capturing everything about a test in a relational database that is required to reproduce the results of that test. TALENT provides a simple, yet powerful, user interface to quickly acquire, process, and analyze waveform test data. The software tool has also been expanded recently to handle sensors whose output is proportional to rotation angle, or rotation rate. As an example of this new processing capability, we show results from testing the new ATA ARS-16 rotational seismometer. The test data was collected at the USGS ASL. Four datasets were processed: 1) 1 Hz with increasing amplitude, 2) 4 Hz with increasing amplitude, 3) 16 Hz with increasing amplitude and 4) twenty-six discrete frequencies between 0.353 Hz to 64 Hz. The results are compared to manufacture-supplied data sheets.
Uncertainty Evaluation of Residential Central Air-conditioning Test System
NASA Astrophysics Data System (ADS)
Li, Haoxue
2018-04-01
According to national standards, property tests of air-conditioning are required. However, test results could be influenced by the precision of apparatus or measure errors. Therefore, uncertainty evaluation of property tests should be conducted. In this paper, the uncertainties are calculated on the property tests of Xinfei13.6 kW residential central air-conditioning. The evaluation result shows that the property tests are credible.
Fujita, Yurika; Kasamatsu, Toshio; Ikeda, Naohiro; Nishiyama, Naohiro; Honda, Hiroshi
2016-01-15
Although in vitro chromosomal aberration tests and micronucleus tests have been widely used for genotoxicity evaluation, false-positive results have been reported under strong cytotoxic conditions. To reduce false-positive results, the new Organization for Economic Co-operation and Development (OECD) test guideline (TG) recommends the use of a new cytotoxicity index, relative increase in cell count or relative population doubling (RICC/RPD), instead of the traditionally used index, relative cell count (RCC). Although the use of the RICC/RPD may result in different outcomes and require re-evaluation of tested substances, it is impractical to re-evaluate all existing data. Therefore, we established a method to estimate test results from existing RCC data. First, we developed formulae to estimate RICC/RPD from RCC without cell counts by considering cell doubling time and experiment time. Next, the accuracy of the cytotoxicity index transformation formulae was verified by comparing estimated RICC/RPD and measured RICC/RPD for 3 major chemicals associated with false-positive genotoxicity test results: ethyl acrylate, eugenol and p-nitrophenol. Moreover, 25 compounds with false-positive in vitro chromosomal aberration (CA) test results were re-evaluated to establish a retrospective evaluation method based on derived estimated RICC/RPD values. The estimated RICC/RPD values were in good agreement with the measured RICC/RPD values for every concentration and chemical, and the estimated RICC suggested the possibility that 12 chemicals (48%) with previously judged false-positive results in fact had negative results. Our method enables transformation of RCC data into RICC/RPD values with a high degree of accuracy and will facilitate comprehensive retrospective evaluation of test results. Copyright © 2015 Elsevier B.V. All rights reserved.
Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen
2004-10-01
Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.
2013-09-01
ER D C/ G SL T R -1 3 -2 4 Evaluation of Precast Panels for Airfield Pavement Repair Phase II: Results of Accelerated Pavement Testing...default. ERDC/GSL TR-13-24 September 2013 Evaluation of Precast Panels for Airfield Pavement Repair Phase II: Results of Accelerated Pavement ... pavement testing using a C-17 load cart to evaluate the performance of a precast portland cement concrete (PCC) pavement repair system. The system
A multi‐centre evaluation of nine rapid, point‐of‐care syphilis tests using archived sera
Herring, A J; Ballard, R C; Pope, V; Adegbola, R A; Changalucha, J; Fitzgerald, D W; Hook, E W; Kubanova, A; Mananwatte, S; Pape, J W; Sturm, A W; West, B; Yin, Y P; Peeling, R W
2006-01-01
Objectives To evaluate nine rapid syphilis tests at eight geographically diverse laboratory sites for their performance and operational characteristics. Methods Tests were compared “head to head” using locally assembled panels of 100 archived (50 positive and 50 negative) sera at each site using as reference standards the Treponema pallidum haemagglutination or the T pallidum particle agglutination test. In addition inter‐site variation, result stability, test reproducibility and test operational characteristics were assessed. Results All nine tests gave good performance relative to the reference standard with sensitivities ranging from 84.5–97.7% and specificities from 84.5–98%. Result stability was variable if result reading was delayed past the recommended period. All the tests were found to be easy to use, especially the lateral flow tests. Conclusions All the tests evaluated have acceptable performance characteristics and could make an impact on the control of syphilis. Tests that can use whole blood and do not require refrigeration were selected for further evaluation in field settings. PMID:17118953
Economic evaluations of point of care testing strategies for active tuberculosis.
Zwerling, Alice; Dowdy, David
2013-06-01
Point of care (POC) diagnostics are often hailed as having the potential to transform tuberculosis (TB) control efforts. However, POC testing is better conceptualized as a system of diagnosis and treatment, not simply a test that can provide rapid, deployable results. Economic evaluations may help decision makers allocate scarce resources for TB control, but evaluations of POC testing face unique challenges that include evaluating the full diagnostic system, incorporating implementation costs, translating diagnostic results into health and accounting for downstream treatment costs. For economic evaluations to reach their full potential as decision-making tools for POC testing in TB, these challenges must be understood and addressed.
Indoor test for thermal performance evaluation on the Sunworks (air) solar collector
NASA Technical Reports Server (NTRS)
1978-01-01
The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a Sunworks single glazed air solar collector under simulated conditions are described. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.
Reducing measurement errors during functional capacity tests in elders.
da Silva, Mariane Eichendorf; Orssatto, Lucas Bet da Rosa; Bezerra, Ewertton de Souza; Silva, Diego Augusto Santos; Moura, Bruno Monteiro de; Diefenthaeler, Fernando; Freitas, Cíntia de la Rocha
2018-06-01
Accuracy is essential to the validity of functional capacity measurements. To evaluate the error of measurement of functional capacity tests for elders and suggest the use of the technical error of measurement and credibility coefficient. Twenty elders (65.8 ± 4.5 years) completed six functional capacity tests that were simultaneously filmed and timed by four evaluators by means of a chronometer. A fifth evaluator timed the tests by analyzing the videos (reference data). The means of most evaluators for most tests were different from the reference (p < 0.05), except for two evaluators for two different tests. There were different technical error of measurement between tests and evaluators. The Bland-Altman test showed difference in the concordance of the results between methods. Short duration tests showed higher technical error of measurement than longer tests. In summary, tests timed by a chronometer underestimate the real results of the functional capacity. Difference between evaluators' reaction time and perception to determine the start and the end of the tests would justify the errors of measurement. Calculation of the technical error of measurement or the use of the camera can increase data validity.
NASA Technical Reports Server (NTRS)
Szuch, J. R.; Soeder, J. F.; Seldner, K.; Cwynar, D. S.
1977-01-01
The design, evaluation, and testing of a practical, multivariable, linear quadratic regulator control for the F100 turbofan engine were accomplished. NASA evaluation of the multivariable control logic and implementation are covered. The evaluation utilized a real time, hybrid computer simulation of the engine. Results of the evaluation are presented, and recommendations concerning future engine testing of the control are made. Results indicated that the engine testing of the control should be conducted as planned.
Effects of handcuffs on neuropsychological testing: Implications for criminal forensic evaluations.
Biddle, Christine M; Fazio, Rachel L; Dyshniku, Fiona; Denney, Robert L
2018-01-01
Neuropsychological evaluations are increasingly performed in forensic contexts, including in criminal settings where security sometimes cannot be compromised to facilitate evaluation according to standardized procedures. Interpretation of nonstandardized assessment results poses significant challenges for the neuropsychologist. Research is limited in regard to the validation of neuropsychological test accommodation and modification practices that deviate from standard test administration; there is no published research regarding the effects of hand restraints upon neuropsychological evaluation results. This study provides preliminary results regarding the impact of restraints on motor functioning and common neuropsychological tests with a motor component. When restrained, performance on nearly all tests utilized was significantly impacted, including Trail Making Test A/B, a coding test, and several tests of motor functioning. Significant performance decline was observed in both raw scores and normative scores. Regression models are also provided in order to help forensic neuropsychologists adjust for the effect of hand restraints on raw scores of these tests, as the hand restraints also resulted in significant differences in normative scores; in the most striking case there was nearly a full standard deviation of discrepancy.
NASA Astrophysics Data System (ADS)
Qiu, Feng; Dai, Guang; Zhang, Ying
According to the acoustic emission information and the appearance inspection information of tank bottom online testing, the external factors associated with tank bottom corrosion status are confirmed. Applying artificial neural network intelligent evaluation method, three tank bottom corrosion status evaluation models based on appearance inspection information, acoustic emission information, and online testing information are established. Comparing with the result of acoustic emission online testing through the evaluation of test sample, the accuracy of the evaluation model based on online testing information is 94 %. The evaluation model can evaluate tank bottom corrosion accurately and realize acoustic emission online testing intelligent evaluation of tank bottom.
Paratransit Vehicle Test and Evaluation : Volume 3. Handling Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume III) presents the test procedures and results of the handling test series. The test determined the steering and handling characteristics o...
ERIC Educational Resources Information Center
Evers, Arne; Sijtsma, Klaas; Lucassen, Wouter; Meijer, Rob R.
2010-01-01
This article describes the 2009 revision of the Dutch Rating System for Test Quality and presents the results of test ratings from almost 30 years. The rating system evaluates the quality of a test on seven criteria: theoretical basis, quality of the testing materials, comprehensiveness of the manual, norms, reliability, construct validity, and…
Image quality evaluation of full reference algorithm
NASA Astrophysics Data System (ADS)
He, Nannan; Xie, Kai; Li, Tong; Ye, Yushan
2018-03-01
Image quality evaluation is a classic research topic, the goal is to design the algorithm, given the subjective feelings consistent with the evaluation value. This paper mainly introduces several typical reference methods of Mean Squared Error(MSE), Peak Signal to Noise Rate(PSNR), Structural Similarity Image Metric(SSIM) and feature similarity(FSIM) of objective evaluation methods. The different evaluation methods are tested by Matlab, and the advantages and disadvantages of these methods are obtained by analyzing and comparing them.MSE and PSNR are simple, but they are not considered to introduce HVS characteristics into image quality evaluation. The evaluation result is not ideal. SSIM has a good correlation and simple calculation ,because it is considered to the human visual effect into image quality evaluation,However the SSIM method is based on a hypothesis,The evaluation result is limited. The FSIM method can be used for test of gray image and color image test, and the result is better. Experimental results show that the new image quality evaluation algorithm based on FSIM is more accurate.
Technical Evaluation Motor No. 10 (TEM-10)
NASA Technical Reports Server (NTRS)
1993-01-01
Technical Evaluation Motor No. 10 (TEM-10) was static fired on 27 Apr. 1993 at the Thiokol Corporation full-scale motor static test bay, T-24. This final test report documents the procedures, performance, and results of the static test firing of TEM-10. All observations, discussions, conclusions, and recommendations contained are final. Included is a presentation and discussion of TEM-10 performance, anomalies, and test results in concurrence with the objectives outlined in CTP-0110, Revision D, Space Shuttle Technical Evaluation Motor No. 10 (TEM-10) Static Fire Test Plan.
Applying an overstress principle in accelerated testing of absorbing mechanisms
NASA Astrophysics Data System (ADS)
Tsyss, V. G.; Sergaeva, M. Yu; Sergaev, A. A.
2018-04-01
The relevance of using overstress test as a forced one to determine the pneumatic absorber lifespan was studied. The obtained results demonstrated that at low load overstress the relative error for the absorber lifespan evaluation is no more than 3%. This means that the test results spread has almost no effect on the lifespan evaluation, and this effect is several times less than that at high load overstress tests. Accelerated testing of absorbers with low load overstress is more acceptable since the relative error for the lifespan evaluation is negligible.
Paratransit Vehicle Test and Evaluation : Volume 2. Acceleration and Interior Measurement Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume II) presents the test procedure and results of the acceleration and interior measurement test series. The tests determined the acceleratio...
Paratransit Vehicle Test and Evaluation : Volume 5. Noise Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype paratransit vehicles were conducted. This volume (Volume V) presents the test procedures and results of the noise tests conducted on the two paratransit vehicles and the baseline test vehicle. The te...
Evaluation of Inter-Mountain Labs infrasound sensors : July 2007.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Darren M.
2007-10-01
Sandia National Laboratories has tested and evaluated three Inter Mountain Labs infrasound sensors. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Inter Mountain Labs (IML) infrasound sensor model SS. The results of this evaluation were only comparedmore » to relevant noise models; due to a lack of manufactures documentation notes on the sensors under test prior to testing. The tests selected for this system were chosen to demonstrate different performance aspects of the components under test.« less
Paratransit Vehicle Test and Evaluation : Volume 4. Fuel Economy Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume IV) presents the test procedures and results of the fuel economy tests. The test series determined the fuel economy of the vehicles as the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, N.; Davis, S.
1979-07-01
Performance and handling tests on the Calspan RSV were performed in Italy by the Istituto Sperimentale Auto E Motori (ISAM) and in West Germany by Volkswagenwerk AG Wolfsburg. The ISAM tests evaluated the Calspan RSV in the areas of fuel economy, vehicle response, braking and handling, and driver environment. The Volkswagen tests evaluated the Calspan RSV in the areas of braking, steering, handling, and overturning immunity. The ISAM tests are unlike any previously used to evaluate American vehicles. Therefore, the Calspan RSV results are compared to those of ten European cars which had undergone identical tests. The Volkswagen test proceduresmore » were identical to those specified in the Research Safety Vehicle program. The Calspan RSV results are compared to the RSV specifications for these tests.« less
Technical Evaluation Motor No. 7 (TEM-07)
NASA Technical Reports Server (NTRS)
Hugh, Phil
1991-01-01
Technical Evaluation Motor Number 7 (TEM-7) was a full scale, full-duration static test firing of a high performance motor (HPM) configuration solid rocket motor (SRM) with nozzle vectoring. The static test fire occurred on 11 December 1990 at the Thiokol Corporation Static Test Bay T-97. Documented here are the procedures, performance, and results available through 22 January 1991. Critical post test hardware activities and assessment of the test data are not complete. A completed test report will be submitted 60 days after the test date. Included here is a presentation and discussion of the TEM-7 performance, anomalies, and test result concurrence with the objectives outlined in CTP-0107 Revision A, Space Shuttle Technical Evaluation Motor number 7 (TEM-07) Static Fire Test Plan.
Smith, M; Murphy, D; Laxmisan, A; Sittig, D; Reis, B; Esquivel, A; Singh, H
2013-01-01
Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider's prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA's EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility's "test" EHR system, thus demonstrating technical compatibility. To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results.
Comparison of Development Test and Evaluation and Overall Program Estimate at Completion
2011-03-01
of the overall model and parameter. In addition to 36 the Shapiro-Wilkes test , and Cook’s Distance overlay plot we used the Breusch - Pagan test to...Transformed Model Finally, we evaluated our log transformed model using the Breusch - Pagan test . The results return a value of .51, thus confirming our...COMPARISON OF DEVELOPMENT TEST AND EVALUATION AND OVERALL
Smith, M.; Murphy, D.; Laxmisan, A.; Sittig, D.; Reis, B.; Esquivel, A.; Singh, H.
2013-01-01
Summary Background Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider’s prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. Objectives The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. Methods We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA’s EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Results Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility’s “test” EHR system, thus demonstrating technical compatibility. Conclusion To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results. PMID:24155789
Technical Evaluation Motor No. 7 (TEM-7)
NASA Technical Reports Server (NTRS)
Hughes, Phil
1991-01-01
The Technical Evaluation Motor No. 7 (TEM-7) test was a full-scale, full duration static test firing of a high performance motor-configuration solid rocket motor with nozzle vectoring. The final test report documents the procedures, performance, and results of the static test firing of TEM-7. All observations, discussions, conclusions, and recommendations included in the report are complete and final except for the TEM-7 fixed housing unbond investigation. A presentation and discussion of TEM-7 performance, anomalies, and test result concurrence with the objectives outlined in CTP-0107, Rev A, Space Shuttle Technical Evaluation Motor No. 7 (TEM-7) Static Fire Test Plan are included.
NASA Astrophysics Data System (ADS)
Strader, Anne; Schorlemmer, Danijel; Beutin, Thomas
2017-04-01
The Global Earthquake Activity Rate Model (GEAR1) is a hybrid seismicity model, constructed from a loglinear combination of smoothed seismicity from the Global Centroid Moment Tensor (CMT) earthquake catalog and geodetic strain rates (Global Strain Rate Map, version 2.1). For the 2005-2012 retrospective evaluation period, GEAR1 outperformed both parent strain rate and smoothed seismicity forecasts. Since 1. October 2015, GEAR1 has been prospectively evaluated by the Collaboratory for the Study of Earthquake Predictability (CSEP) testing center. Here, we present initial one-year test results of the GEAR1, GSRM and GSRM2.1, as well as localized evaluation of GEAR1 performance. The models were evaluated on the consistency in number (N-test), spatial (S-test) and magnitude (M-test) distribution of forecasted and observed earthquakes, as well as overall data consistency (CL-, L-tests). Performance at target earthquake locations was compared between models using the classical paired T-test and its non-parametric equivalent, the W-test, to determine if one model could be rejected in favor of another at the 0.05 significance level. For the evaluation period from 1. October 2015 to 1. October 2016, the GEAR1, GSRM and GSRM2.1 forecasts pass all CSEP likelihood tests. Comparative test results show statistically significant improvement of GEAR1 performance over both strain rate-based forecasts, both of which can be rejected in favor of GEAR1. Using point process residual analysis, we investigate the spatial distribution of differences in GEAR1, GSRM and GSRM2 model performance, to identify regions where the GEAR1 model should be adjusted, that could not be inferred from CSEP test results. Furthermore, we investigate whether the optimal combination of smoothed seismicity and strain rates remains stable over space and time.
Liew, Jeffrey; Lench, Heather C; Kao, Grace; Yeh, Yu-Chen; Kwok, Oi-man
2014-01-01
Standardized testing has become a common form of student evaluation with high stakes, and limited research exists on understanding the roles of students' personality traits and social-evaluative threat on their academic performance. This study examined the roles of avoidance temperament (i.e., fear and behavioral inhibition) and evaluative threat (i.e., fear of failure and being viewed as unintelligent) in standardized math test and course grades in college students. Undergraduate students (N=184) from a large public university were assessed on temperamental fear and behavioral inhibition. They were then given 15 minutes to complete a standardized math test. After the test, students provided data on evaluative threat and their math performance (scores on standardized college entrance exam and average grades in college math courses). Results indicate that avoidance temperament was linked to social-evaluative threat and low standardized math test scores. Furthermore, evaluative threat mediated the influence of avoidance temperament on both types of math performance. Results have educational and clinical implications, particularly for students at risk for test anxiety and underperformance. Interventions targeting emotion regulation and stress management skills may help individuals reduce their math and test anxieties.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jetter, R. I.; Messner, M. C.; Sham, T. -L.
The goal of the proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology is to incorporate an SMT data based approach for creep-fatigue damage evaluation into the EPP methodology to avoid the separate evaluation of creep and fatigue damage and eliminate the requirement for stress classification in current methods; thus greatly simplifying evaluation of elevated temperature cyclic service. This methodology should minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed methodology and to verify the applicability of the code rules, analytical studies and evaluation of thermomechanical test results continuedmore » in FY17. This report presents the results of those studies. An EPP strain limits methodology assessment was based on recent two-bar thermal ratcheting test results on 316H stainless steel in the temperature range of 405 to 7050C. Strain range predictions from the EPP evaluation of the two-bar tests were also evaluated and compared with the experimental results. The role of sustained primary loading on cyclic life was assessed using the results of pressurized SMT data from tests on Alloy 617 at 9500C. A viscoplastic material model was used in an analytic simulation of two-bar tests to compare with EPP strain limits assessments using isochronous stress strain curves that are consistent with the viscoplastic material model. A finite element model of a prior 304H stainless steel Oak Ridge National Laboratory (ORNL) nozzle-to-sphere test was developed and used for an EPP strain limits and creep-fatigue code case damage evaluations. A theoretical treatment of a recurring issue with convergence criteria for plastic shakedown illustrated the role of computer machine precision in EPP calculations.« less
Electrochemical Test Method for Evaluating Long-Term Propellant-Material Compatibility
1978-12-01
matrix of test conditions is illustrated in Fig. 13. A statistically designed test matrix (Graeco-Latin Cube) could not be used because of passivation...ears simulated time results in a findl decomposition level of 0.753 mg/cm The data was examined using statistical techniqves to evaluate the relative...metals. The compatibility of all nine metals was evaluated in hydrazine containing water and chloride. The results of the statistical analy(is
Construction and Evaluation of Reliability and Validity of Reasoning Ability Test
ERIC Educational Resources Information Center
Bhat, Mehraj A.
2014-01-01
This paper is based on the construction and evaluation of reliability and validity of reasoning ability test at secondary school students. In this paper an attempt was made to evaluate validity, reliability and to determine the appropriate standards to interpret the results of reasoning ability test. The test includes 45 items to measure six types…
Reaction propagation test. Evaluation of the behavior of nonmetallic materials in hydrogen
NASA Technical Reports Server (NTRS)
Smith, I. D.
1972-01-01
Results of tests conducted to evaluate the behavior of nonmetallic materials in hydrogen are described. The reaction propagation test simulates the conditions resulting from the interaction of an electrical wire in an overload condition in contract with a material in the test medium. The test is designed to evaluate the behavior of a material subjected to an energy input (usually heat) sufficient to cause a reaction which propagates to consume larger quantities of the material. Ten nonmetallic materials were evaluated to establish baseline data on the behavior of nonmetallic materials in hydrogen and to characterize, on an initial basis, one mode of material failure considered to be a factor pertinent to the safe use of a material in hydrogen.
DOT National Transportation Integrated Search
1999-09-01
This report presents the results of the field test portion of the Development, Evaluation, and Application of Performance-Based Brake Testing Technologies sponsored by the Federal Highway Administrations (FHWA) Office of Motor Carriers.
DOT National Transportation Integrated Search
2011-10-30
Main aim of this project was to evaluate alternate standard test methods for stress corrosion cracking (SCC) and compare them with the results from slow strain rate test (SSRT) results under equivalent environmental conditions. Other important aim of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saunders, G.C.
1977-01-01
A rapid enzyme-labeled antibody (ELA) microtechnique for the screening of swine for hog cholera antibodies was developed and evaluated with a blind study, using a 640-sample hog cholera serum bank. The total time to run a group of 22 samples was approximately 1 hour. The ELA test results correlated >99% with hog cholera serum-neutralization test results on the same serums. Test results also indicated that the ELA test shares with the hog cholera serum-neutralization test the problem of cross reactions between the antibodies of hog cholera and bovine viral diarrhea.
Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security
West, David L.; Wood, Nathan L.; Forrester, Christina D.
2017-12-01
This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less
Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security
DOE Office of Scientific and Technical Information (OSTI.GOV)
West, David L.; Wood, Nathan L.; Forrester, Christina D.
This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less
Test and evaluation of the HIDEC engine uptrim algorithm
NASA Technical Reports Server (NTRS)
Ray, R. J.; Myers, L. P.
1986-01-01
The highly integrated digital electronic control (HIDEC) program will demonstrate and evaluate the improvements in performance and mission effectiveness that result from integrated engine-airframe control systems. Performance improvements will result from an adaptive engine stall margin mode, a highly integrated mode that uses the airplane flight conditions and the resulting inlet distortion to continuously compute engine stall margin. When there is excessive stall margin, the engine is uptrimmed for more thrust by increasing engine pressure ratio (EPR). The EPR uptrim logic has been evaluated and implemented into computer simulations. Thrust improvements over 10 percent are predicted for subsonic flight conditions. The EPR uptrim was successfully demonstrated during engine ground tests. Test results verify model predictions at the conditions tested.
DOT National Transportation Integrated Search
2010-03-01
Objectives: Evaluate the usefulness of the dynamic modulus and flow number tests in moisture-susceptibility evaluation, Compare the results to those achieved using the AASHTO T 283 test, Study the effect of different methods of sample conditioning an...
Sharma, Vishal; Sundar, Sudha S; Breheny, Katie; Monahan, Mark; Sutton, Andrew John
2016-06-01
There are multiple tests available that can help diagnose ovarian cancer, and the cost-effective analysis of these diagnostic interventions is essential for making well-informed decisions regarding resource allocation. There are multiple factors that can impact on the conclusions drawn from economic evaluations including test accuracy, the impact of the testing pathway on patient costs and outcomes, and delays along the ovarian cancer test-treat pathway. The objective of this study was to evaluate how test accuracy, the choice of perspective, and delays along the testing and diagnostic pathway have been incorporated in economic evaluations of testing for ovarian cancer. A systematic review of published literature was undertaken to identify economic evaluations (eg, cost-effectiveness, cost-utility analysis) focused on testing and diagnosis for ovarian cancer. Seven studies met the inclusion criteria. Six studies incorporated test accuracy and its impact on patients to some extent. Four studies adopted a societal perspective, but only one considered the costs incurred by patients on the testing and diagnosis pathway. Where delays on the testing pathway were incorporated into the analysis, these were frequently due to false-negative test results leading to delays in patients accessing treatment. Any anxiety that patients might experience as a result of a positive test was not considered in these studies. The impact on patients of receiving a positive test in terms of anxiety and the costs incurred by patients having to attend for testing and diagnosis are rarely considered. Delays along the testing and diagnosis pathway can have a major effect on patient outcomes, and it is important that these are acknowledged in economic evaluations focused on testing. Future economic analysis should incorporate these key determinants in order that diagnostic tests for ovarian cancer can be robustly evaluated.
Highway Vehicle Retrofit Evaluation : Phase 2. Report. Testing and Final Evaluation Results.
DOT National Transportation Integrated Search
1976-11-01
This report presents the results of engine dynamometer and vehicle chassis dynamometer tests conducted with selected automotive retrofit devices in the classes of ultrasonic carburetors, high-velocity intake manifolds, tuned exhaust systems, and high...
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... purposes except when the results of pre-bronchodilator pulmonary function tests are normal or when the... schedule unless the post-bronchodilator results were poorer than the pre-bronchodilator results. In those...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When...
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... purposes except when the results of pre-bronchodilator pulmonary function tests are normal or when the... schedule unless the post-bronchodilator results were poorer than the pre-bronchodilator results. In those...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When...
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... purposes except when the results of pre-bronchodilator pulmonary function tests are normal or when the... schedule unless the post-bronchodilator results were poorer than the pre-bronchodilator results. In those...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When...
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... purposes except when the results of pre-bronchodilator pulmonary function tests are normal or when the... schedule unless the post-bronchodilator results were poorer than the pre-bronchodilator results. In those...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When...
Simonsen, Daniel; Nielsen, Ida F; Spaich, Erika G; Andersen, Ole K
2017-05-02
The present paper describes the design and evaluation of an automated version of the Modified Jebsen Test of Hand Function (MJT) based on the Microsoft Kinect sensor. The MJT was administered twice to 11 chronic stroke subjects with varying degrees of hand function deficits. The test times of the MJT were evaluated manually by a therapist using a stopwatch, and automatically using the Microsoft Kinect sensor. The ground truth times were assessed based on inspection of the video-recordings. The agreement between the methods was evaluated along with the test-retest performance. The results from Bland-Altman analysis showed better agreement between the ground truth times and the automatic MJT time evaluations compared to the agreement between the ground truth times and the times estimated by the therapist. The results from the test-retest performance showed that the subjects significantly improved their performance in several subtests of the MJT, indicating a practice effect. The results from the test showed that the Kinect can be used for automating the MJT.
Usefulness of routine preoperative testing in a developing country: a prospective study
Bordes, Julien; Cungi, Pierre-Julien; Savoie, Pierre-Henry; Bonnet, Stéphane; Kaiser, Eric
2015-01-01
Introduction The assessment of anesthetic risks is an essential component of preoperative evaluation. In developing world, preanesthesia evaluation may be challenging because patient's medical history and records are scare, and language barrier limits physical examination. Our objective was to evaluate the impact of routine preoperative testing in a low-resources setting. Methods Prospective observational study performed in a French forward surgical unit in Abidjan, Ivory Coast. 201 patients who were scheduled for non urgent surgery were screened with routine laboratory exams during preoperative evaluation. Changes in surgery were assessed (delayed or scheduled). Results Abnormal hemoglobin findings were reported in 35% of patients, abnormal WBC count in 11,1% of patients, abnormal platelets in 15,3% of patients. Positive HIV results were found in 8,3% of cases. Routine tests represented 43,6% of changes causes. Conclusion Our study showed that in a developing country, routine preoperative tests showed abnormal results up to 35% of cases, and represented 43,5% of delayed surgery causes. The rate of tests leading to management changes varied widely, from 0% to 8,3%. These results suggested that selected tests would be useful to diagnose diseases that required treatment before non urgent surgery. However, larger studies are needeed to evaluate the cost/benefit ratio and the clinical impact of such a strategy. PMID:26516395
Evaluation of Variability in Resilient Modulus Test Results (ASTM D4123)
DOT National Transportation Integrated Search
1989-10-01
Samples of asphalt mixture were evaluated in the laboratory under various conditions to evaluate the repeatability of the resilient modulus test and to evaluate the effect of stress on the measured resilient modulus. Some of the samples were prepared...
Gonzalez-Neira, Eliana Maria; Jimenez-Mendoza, Claudia Patricia; Rugeles-Quintero, Saul
2016-01-01
Objective: This study aims at determining if a collection of 16 motor tests on a physical simulator can objectively discriminate and evaluate practitioners' competency level, i.e. novice, resident, and expert. Methods: An experimental design with three study groups (novice, resident, and expert) was developed to test the evaluation power of each of the 16 simple tests. An ANOVA and a Student Newman-Keuls (SNK) test were used to analyze results of each test to determine which of them can discriminate participants' competency level. Results: Four of the 16 tests used discriminated all of the three competency levels and 15 discriminated at least two of the three groups (α= 0.05). Moreover, other two tests differentiate beginners' level from intermediate, and other seven tests differentiate intermediate level from expert. Conclusion: The competency level of a practitioner of minimally invasive surgery can be evaluated by a specific collection of basic tests in a physical surgical simulator. Reduction of the number of tests needed to discriminate the competency level of surgeons can be the aim of future research. PMID:27226664
Hand sensibility measures used by therapists.
Mielke, K; Novak, C B; Mackinnon, S E; Feely, C A
1996-03-01
Sensory evaluations are frequently used to assess patients with functional loss resulting from nerve injury. The results of these tests are routinely utilized by hand surgeons as an indication for conservative management or surgical intervention in the evaluation of surgical outcome and in the determination of disability ratings. Reports in the literature regarding specific tests for sensibility show variation in their application. The purpose of this study was to evaluate which tests are used to evaluate hand sensibility and the techniques of application currently used by hand therapists. Two hundred members of the American Society of Hand Therapists were randomly selected and a survey was sent to these members. The results of this study identify the need to develop standardized protocols for sensory evaluations and the need for therapists to follow the standardized methods for administration of moving and static two-point discrimination, and Semmes-Weinstein monofilaments, if comparisons of results between centers are to be meaningful.
NASA Technical Reports Server (NTRS)
Ray, R. J.; Myers, L. P.
1986-01-01
The highly integrated digital electronic control (HIDEC) program will demonstrate and evaluate the improvements in performance and mission effectiveness that result from integrated engine-airframe control systems. Performance improvements will result from an adaptive engine stall margin mode, a highly integrated mode that uses the airplane flight conditions and the resulting inlet distortion to continuously compute engine stall margin. When there is excessive stall margin, the engine is uptrimmed for more thrust by increasing engine pressure ratio (EPR). The EPR uptrim logic has been evaluated and implemente into computer simulations. Thrust improvements over 10 percent are predicted for subsonic flight conditions. The EPR uptrim was successfully demonstrated during engine ground tests. Test results verify model predictions at the conditions tested.
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When the results of a maximum exercise capacity test are of record and are 20 ml/kg/min or less. If a maximum exercise capacity test is not of record, evaluate based on alternative criteria. (ii) When...
An evaluation of the hemiplegic subject based on the Bobath approach. Part III. A validation study.
Arsenault, A B; Dutil, E; Lambert, J; Corriveau, H; Guarna, F; Drouin, G
1988-01-01
Sixty-two hemiplegic subjects were treated with the Bobath approach for a period of three months. During this time they were evaluated on three occasions. The testing battery consisted of a Bobath evaluation, the Brunnstrom scale, the Fugl-Meyer test, the Upper Extremity Functional Test (UEFT) and the Present Pain Intensity (PPI) of the McGill pain questionnaire. A Friedman analysis of variance showed that, except for pain, all the protocols used disclosed significant progress (p less than 0.001) over time in terms of motor recovery. Except for pain, the results of the Bobath evaluation were significantly correlated (Spearman's Rho, p less than 0.001) with the results of the other testing procedures. It is concluded that the new Bobath evaluation proposed in a previous paper is as sensitive in depicting progress in motor recovery over time as are the other testing procedures used. Furthermore, this new evaluation seems to be measuring similar properties to the other tests. However, pain (PPI) appears not to be an important dependent variable.
DeBoer, D J; Hillier, A
2001-09-20
Serum-based in vitro "allergy tests" are commercially available to veterinarians, and are widely used in diagnostic evaluation of a canine atopic patient. Following initial clinical diagnosis, panels of allergen-specific IgE measurements may be performed in an attempt to identify to which allergens the atopic dog is hypersensitive. Methodology for these tests varies by laboratory; few critical studies have evaluated performance of these tests, and current inter-laboratory standardization and quality control measures are inadequate. Other areas where information is critically limited include the usefulness of these tests in diagnosis of food allergy, the effect of extrinsic factors such as season of the year on results, and the influence of corticosteroid treatment on test results. Allergen-specific IgE serological tests are never completely sensitive, nor completely specific. There is only partial correlation between the serum tests and intradermal testing; however, the significance of discrepant results is unknown and unstudied. Variation in test methodologies along with the absence of universal standardization and reporting procedures have created confusion, varying study results, and an inability to compare between studies performed by different investigators.
Economic Evaluations of Pathology Tests, 2010-2015: A Scoping Review.
Watts, Rory D; Li, Ian W; Geelhoed, Elizabeth A; Sanfilippo, Frank M; St John, Andrew
2017-09-01
Concerns about pathology testing such as the value provided by new tests and the potential for inappropriate utilization have led to a greater need to assess costs and benefits. Economic evaluations are a formal method of analyzing costs and benefits, yet for pathology tests, questions remain about the scope and quality of the economic evidence. To describe the extent and quality of published evidence provided by economic evaluations of pathology tests from 2010 to 2015. Economic evaluations relating to pathology tests from 2010 to 2015 were reviewed. Eight databases were searched for published studies, and details recorded for the country, clinical focus, type of testing, and consideration of sensitivity, specificity, and false test results. The reporting quality of studies was assessed using the Consolidated Health Economic Evaluation Reporting Standards checklist and cost-effectiveness ratios were analyzed for publication bias. We found 356 economic evaluations of pathology tests, most of which regarded developed countries. The most common economic evaluations were cost-utility analyses and the most common clinical focus was infectious diseases. More than half of the studies considered sensitivity and specificity, but few studies considered the impact of false test results. The average Consolidated Health Economic Evaluation Reporting Standards checklist score was 17 out of 24. Cost-utility ratios were commonly less than $10,000/quality-adjusted life-year or more than $200,000/quality-adjusted life-year. The number of economic evaluations of pathology tests has increased in recent years, but the rate of increase has plateaued. Furthermore, the quality of studies in the past 5 years was highly variable, and there is some question of publication bias in reporting cost-effectiveness ratios. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1979-01-01
All evaluation tests were performed at room ambient pressure and temperature, with discharges at a 2 hour rate. Tests consisted of phenolphthalein leak tests, three capacity tests, an auxiliary electrode test, a charge retention test, an internal short test, a charge efficiency test, overcharge tests, and a pressure versus capacity test. Results of the tests and recommendations for improvements in manufacturing are presented.
Methods Used in Economic Evaluations of Chronic Kidney Disease Testing — A Systematic Review
Sutton, Andrew J.; Breheny, Katie; Deeks, Jon; Khunti, Kamlesh; Sharpe, Claire; Ottridge, Ryan S.; Stevens, Paul E.; Cockwell, Paul; Kalra, Philp A.; Lamb, Edmund J.
2015-01-01
Background The prevalence of chronic kidney disease (CKD) is high in general populations around the world. Targeted testing and screening for CKD are often conducted to help identify individuals that may benefit from treatment to ameliorate or prevent their disease progression. Aims This systematic review examines the methods used in economic evaluations of testing and screening in CKD, with a particular focus on whether test accuracy has been considered, and how analysis has incorporated issues that may be important to the patient, such as the impact of testing on quality of life and the costs they incur. Methods Articles that described model-based economic evaluations of patient testing interventions focused on CKD were identified through the searching of electronic databases and the hand searching of the bibliographies of the included studies. Results The initial electronic searches identified 2,671 papers of which 21 were included in the final review. Eighteen studies focused on proteinuria, three evaluated glomerular filtration rate testing and one included both tests. The full impact of inaccurate test results was frequently not considered in economic evaluations in this setting as a societal perspective was rarely adopted. The impact of false positive tests on patients in terms of the costs incurred in re-attending for repeat testing, and the anxiety associated with a positive test was almost always overlooked. In one study where the impact of a false positive test on patient quality of life was examined in sensitivity analysis, it had a significant impact on the conclusions drawn from the model. Conclusion Future economic evaluations of kidney function testing should examine testing and monitoring pathways from the perspective of patients, to ensure that issues that are important to patients, such as the possibility of inaccurate test results, are properly considered in the analysis. PMID:26465773
Systematic evaluation of non-animal test methods for skin sensitisation safety assessment.
Reisinger, Kerstin; Hoffmann, Sebastian; Alépée, Nathalie; Ashikaga, Takao; Barroso, Joao; Elcombe, Cliff; Gellatly, Nicola; Galbiati, Valentina; Gibbs, Susan; Groux, Hervé; Hibatallah, Jalila; Keller, Donald; Kern, Petra; Klaric, Martina; Kolle, Susanne; Kuehnl, Jochen; Lambrechts, Nathalie; Lindstedt, Malin; Millet, Marion; Martinozzi-Teissier, Silvia; Natsch, Andreas; Petersohn, Dirk; Pike, Ian; Sakaguchi, Hitoshi; Schepky, Andreas; Tailhardat, Magalie; Templier, Marie; van Vliet, Erwin; Maxwell, Gavin
2015-02-01
The need for non-animal data to assess skin sensitisation properties of substances, especially cosmetics ingredients, has spawned the development of many in vitro methods. As it is widely believed that no single method can provide a solution, the Cosmetics Europe Skin Tolerance Task Force has defined a three-phase framework for the development of a non-animal testing strategy for skin sensitization potency prediction. The results of the first phase – systematic evaluation of 16 test methods – are presented here. This evaluation involved generation of data on a common set of ten substances in all methods and systematic collation of information including the level of standardisation, existing test data,potential for throughput, transferability and accessibility in cooperation with the test method developers.A workshop was held with the test method developers to review the outcome of this evaluation and to discuss the results. The evaluation informed the prioritisation of test methods for the next phase of the non-animal testing strategy development framework. Ultimately, the testing strategy – combined with bioavailability and skin metabolism data and exposure consideration – is envisaged to allow establishment of a data integration approach for skin sensitisation safety assessment of cosmetic ingredients.
NASA Astrophysics Data System (ADS)
Riandry, M. A.; Ismet, I.; Akhsan, H.
2017-09-01
This study aims to produce a valid and practical statistical physics course handout on distribution function materials based on STEM. Rowntree development model is used to produce this handout. The model consists of three stages: planning, development and evaluation stages. In this study, the evaluation stage used Tessmer formative evaluation. It consists of 5 stages: self-evaluation, expert review, one-to-one evaluation, small group evaluation and field test stages. However, the handout is limited to be tested on validity and practicality aspects, so the field test stage is not implemented. The data collection technique used walkthroughs and questionnaires. Subjects of this study are students of 6th and 8th semester of academic year 2016/2017 Physics Education Study Program of Sriwijaya University. The average result of expert review is 87.31% (very valid category). One-to-one evaluation obtained the average result is 89.42%. The result of small group evaluation is 85.92%. From one-to-one and small group evaluation stages, averagestudent response to this handout is 87,67% (very practical category). Based on the results of the study, it can be concluded that the handout is valid and practical.
Financial comparison of three testing strategies for detection of estrus in dairy cattle.
Mohammed, H O; Loefler, S; Shearer, J
1990-03-15
Three commercial tests that measure progesterone content in milk were evaluated for accuracy of estrus detection. The tests were evaluated on 96 milk samples collected from Holstein cows at a commercial dairy farm in central Florida. The test results were compared with the results of radioimmunoassay on the same sample. Comparisons were made by calculating the sensitivities, specificities, and predictive values. The significance of the statistical association between the tests and the radioimmunoassay was evaluated by use of the McNemar chi 2 test. Decision-tree analysis was used to determine the most useful testing strategy, considering both cost and accuracy. The cowside progesterone assay on estrus-mount detector-positive cows was more profitable than use of estrus-mount patches alone. The return on investment was higher with the cowside test, making it preferred as a field test for detecting estrus.
Report on FY17 testing in support of integrated EPP-SMT design methods development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yanli .; Jetter, Robert I.; Sham, T. -L.
The goal of the proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology is to incorporate a SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid the separate evaluation of creep and fatigue damage and eliminate the requirement for stress classification in current methods; thus greatly simplifying evaluation of elevated temperature cyclic service. The purpose of this methodology is to minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed methodology and to verify the applicability of the code rules, thermomechanical tests continued in FY17. Thismore » report presents the recent test results for Type 1 SMT specimens on Alloy 617 with long hold times, pressurization SMT on Alloy 617, and two-bar thermal ratcheting test results on SS316H at the temperature range of 405 °C to 705 °C. Preliminary EPP strain range analysis on the two-bar tests are critically evaluated and compared with the experimental results.« less
Gauthier, Lauraine; Dortet, Laurent; Naas, Thierry
2017-01-01
Background There is an urgent need for accurate and rapid diagnostic tests to identify carbapenemase producing enterobacteria (CPE). Here, we have evaluated the Carbapenem Inactivation Method (CIM) test to detect CPEs from cultured colonies. Methods A total of 256 enterobacterial isolates were used to evaluate the performance of the CIM in comparison to Carba NP test and molecular detection used a reference method. Ninety three well-characterized isolates (including 29 non-CPE and 63 CPEs of worldwide origin) with decreased susceptibility to at least one carbapenem were used to (i) evaluate the efficacy of CIM test and (ii) to compare it to the Carba NP test. We also tested different carbapenems to determine the best substrate for this test. Finally, the CIM test was then evaluated prospectively against 164 isolates referred to the French National Reference Center (NRC) for Antimicrobial Resistance from may 2016 to july 2016. Results Based on the results of this retrospective study, sensitivity and specificity of the CIM and the Carba NP test were 92.1% and 100%, respectively. We demonstrated that the meropenem was the best substrate to perform the CIM test since sensitivity and specificity were 81.1% and 100% using ertapenem disk, and 100% and 65,6% using imipenem disk, and respectively. Taking in account the results of retrospective and prospective studies, CIM and Carba NP tests have similar sensitivity, specificity, positive predictive value and negative predictive values being 96.3%, 98.9%, 99.0% and 98.4% for the CIM test versus 96.9%, 100%, 100% and 100% for the Carba NP test. Conclusions Our results confirm that the CIM test may be a useful tool for the reliable confirmation of carbapenemase-activity in enterobacterial isolates, especially in clinical microbiological laboratories with limited resources, no trained personnel, and no specialized equipment. PMID:28158310
Evaluating rodent motor functions: Which tests to choose?
Schönfeld, Lisa-Maria; Dooley, Dearbhaile; Jahanshahi, Ali; Temel, Yasin; Hendrix, Sven
2017-12-01
Damage to the motor cortex induced by stroke or traumatic brain injury (TBI) can result in chronic motor deficits. For the development and improvement of therapies, animal models which possess symptoms comparable to the clinical population are used. However, the use of experimental animals raises valid ethical and methodological concerns. To decrease discomfort by experimental procedures and to increase the quality of results, non-invasive and sensitive rodent motor tests are needed. A broad variety of rodent motor tests are available to determine deficits after stroke or TBI. The current review describes and evaluates motor tests that fall into three categories: Tests to evaluate fine motor skills and grip strength, tests for gait and inter-limb coordination and neurological deficit scores. In this review, we share our thoughts on standardized data presentation to increase data comparability between studies. We also critically evaluate current methods and provide recommendations for choosing the best behavioral test for a new research line. Copyright © 2017 Elsevier Ltd. All rights reserved.
Christopher, David; Adams, Wallace P; Lee, Douglas S; Morgan, Beth; Pan, Ziqing; Singh, Gur Jai Pal; Tsong, Yi; Lyapustina, Svetlana
2007-01-19
The purpose of this article is to present the thought process, methods, and interim results of a PQRI Working Group, which was charged with evaluating the chi-square ratio test as a potential method for determining in vitro equivalence of aerodynamic particle size distribution (APSD) profiles obtained from cascade impactor measurements. Because this test was designed with the intention of being used as a tool in regulatory review of drug applications, the capability of the test to detect differences in APSD profiles correctly and consistently was evaluated in a systematic way across a designed space of possible profiles. To establish a "base line," properties of the test in the simplest case of pairs of identical profiles were studied. Next, the test's performance was studied with pairs of profiles, where some difference was simulated in a systematic way on a single deposition site using realistic product profiles. The results obtained in these studies, which are presented in detail here, suggest that the chi-square ratio test in itself is not sufficient to determine equivalence of particle size distributions. This article, therefore, introduces the proposal to combine the chi-square ratio test with a test for impactor-sized mass based on Population Bioequivalence and describes methods for evaluating discrimination capabilities of the combined test. The approaches and results described in this article elucidate some of the capabilities and limitations of the original chi-square ratio test and provide rationale for development of additional tests capable of comparing APSD profiles of pharmaceutical aerosols.
Evaluation of Nucleic Acid Preservation Cards for West Nile Virus Testing in Dead Birds
Foss, Leslie; Reisen, William K.; Fang, Ying; Kramer, Vicki; Padgett, Kerry
2016-01-01
The California West Nile virus (WNV) Dead Bird Surveillance Program (DBSP) is an important component of WNV surveillance in the state. We evaluated FTA™ and RNASound™ cards as an alternative method for sampling dead birds for WNV molecular testing as these cards allow for more cost effective, rapid, and safer diagnostic sampling than the shipment of bird carcasses. To evaluate accuracy of results among avian sampling regimes, Reverse-Transcription Polymerase Chain Reaction (RT-PCR) results from FTA™ and RNASound™ cards were compared with results from kidney tissue, brain tissue, or oral swabs in lysis buffer in 2012–2013. In addition, RT-PCR results were compared with results from oral swabs tested by rapid antigen tests (RAMP™ and VecTOR™). While test results from the cards were not as sensitive as kidney tissue testing, they were more likely to provide accurate results than rapid antigen tests, and detected WNV in corvids as well as in other passerines, raptors, and waterfowl. Overall, WNV RT-PCR cycle threshold (Ct) scores from the cards were higher than those from tissue testing, but both card products displayed high sensitivity and specificity. American Crow samples provided the highest sensitivity. The cards also proved to be easier and more convenient vehicles for collecting and shipping samples, and in 2014 our program launched use of RNASound™ cards in the DBSP. Both FTA™ and RNASound™ products displayed 96% agreement with tissue results and are an adequate alternative sampling method for WNV dead bird testing. PMID:27341492
Rockwell-Rocketdyne flywheel test results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steele, R.S. Jr.; Babelay, E.F. Jr.; Sutton, B.J.
1981-01-01
Results are presented of the spin test evaluation of the Rockwell-Rocketdyne RPE-10 design flywheel at the Oak Ridge Flywheel Evaluation Laboratory. Details of the static evaluation, including measures of weight, inertia, natural frequencies, and radiography, are also presented. The flywheel was subjected to seven spin cycles with a maximum of 383 rps, 105% of design speed. At that speed, the energy stored was 1.94 kWhr at 36.1 Whr/kg. The maximum speed was limited by the inability of the test facility to accommodate the increasing eccentric shift of both hub disks with increasing speed. No material degradation was observed during themore » testing.« less
Rockwell-Rocketdyne flywheel test results
NASA Astrophysics Data System (ADS)
Steele, R. S., Jr.; Babelay, E. F., Jr.; Sutton, B. J.
1981-01-01
Results are presented of the spin test evaluation of the Rockwell-Rocketdyne RPE-10 design flywheel at the Oak Ridge Flywheel Evaluation Laboratory. Details of the static evaluation, including measures of weight, inertia, natural frequencies, and radiography, are also presented. The flywheel was subjected to seven spin cycles with a maximum of 383 rps, 105% of design speed. At that speed, the energy stored was 1.94 kWhr at 36.1 Whr/kg. The maximum speed was limited by the inability of the test facility to accommodate the increasing eccentric shift of both hub disks with increasing speed. No material degradation was observed during the testing.
Mechanical Properties of Friction Stir Welds in A12195-T8
NASA Technical Reports Server (NTRS)
Kinchen, David G.; Li, Zhixian; Adams, Glynn P.
1999-01-01
An extensive study of the mechanical properties of friction stir welded Al-Li 2195 has been conducted by Lockheed Martin Michoud Space Systems under contract to NASA. The study was part of a development program in which weld parameters were defined for using FSW to assemble large-scale aluminum cryogenic tanks. In excess of 300 feet of 0.320 in. gage plate material was welded and tested. The tests include room temperature and cryogenic temperature tensile tests and surface crack tension (SCT) tests, nondestructive evaluation, metallurgical studies, and photostress analysis. The results of the testing demonstrated improved mechanical properties with FSW as compared to typical fusion welding processes. Increases in ultimate tensile strength, cryogenic enhancement and elongation were observed with the tensile test results. Increased fracture toughness was observed with the SCT results. Nondestructive evaluations were conducted on all welded Joints. No volumetric defects were indicated. Surface indications on the root side of the welds did not significantly affect weld strength. The results of the nondestructive evaluations were confirmed via metallurgical studies. Photostress analysis revealed strain concentrations in multi-pass and heat-repaired FSW's. Details of the tests and results are presented.
SITE PROGRAM EVALUATION OF THE SONOTECH PULSE COMBUSTION BURNER TECHNOLOGY - TECHNICAL RESULTS
A series of demonstration tests was performed at the Environmental Protection Agency's (EPA's) Incineration Research Facility (IRF) under the Superfund Innovative Technology Evaluation (SITE) program. These tests, twelve in all, evaluated a pulse combustion burner technology dev...
NASA Technical Reports Server (NTRS)
Mason, M. G.
1975-01-01
A simulator is described, which was designed for testing and evaluating inertial measuring units, and flight platforms. Mechanical and electrical specifications for the outer, middle, and inner axis are presented. Test results are included.
Factors influencing the virological testing of cornea donors.
Röck, Tobias; Beck, Robert; Jürgens, Stefan; Bartz-Schmidt, Karl Ulrich; Bramkamp, Matthias; Thaler, Sebastian; Röck, Daniel
2017-11-01
To assess the influence of donor, environment, and logistical factors on the results of virological testing of blood samples from cornea donors.Data from 670 consecutive cornea donors were analyzed retrospectively. Logistic regression analysis was used to assess the influence of different factors on the results of virological testing of blood samples from cornea donors.The mean annual rate of donors with serology-reactive or not evaluable result was 14.8% (99 of 670) (range 11.9%-16.9%). The cause of donor death by cancer increased the risk of serology-reactive or not evaluable result (P = .0300). Prolonged time between death and post mortem blood removal was associated with a higher rate of serology-reactive or not evaluable result (P < .0001). Mean monthly temperature including warmer months, differentiating between septic and aseptic donors, sex, and donor age had no significant impact on the results of virological testing of blood samples from cornea donors.The cause of donor death by cancer and a prolonged time between death and post mortem blood removal seem to be mainly responsible for serology-reactive or not evaluable result of blood samples from cornea donors. The percentage of discarded corneas caused by serology-reactive or not evaluable result may be reduced by shortening the period of time between death and post mortem blood removal. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Factors influencing the virological testing of cornea donors
Röck, Tobias; Beck, Robert; Jürgens, Stefan; Bartz-Schmidt, Karl Ulrich; Bramkamp, Matthias; Thaler, Sebastian; Röck, Daniel
2017-01-01
Abstract To assess the influence of donor, environment, and logistical factors on the results of virological testing of blood samples from cornea donors. Data from 670 consecutive cornea donors were analyzed retrospectively. Logistic regression analysis was used to assess the influence of different factors on the results of virological testing of blood samples from cornea donors. The mean annual rate of donors with serology-reactive or not evaluable result was 14.8% (99 of 670) (range 11.9%–16.9%). The cause of donor death by cancer increased the risk of serology-reactive or not evaluable result (P = .0300). Prolonged time between death and post mortem blood removal was associated with a higher rate of serology-reactive or not evaluable result (P < .0001). Mean monthly temperature including warmer months, differentiating between septic and aseptic donors, sex, and donor age had no significant impact on the results of virological testing of blood samples from cornea donors. The cause of donor death by cancer and a prolonged time between death and post mortem blood removal seem to be mainly responsible for serology-reactive or not evaluable result of blood samples from cornea donors. The percentage of discarded corneas caused by serology-reactive or not evaluable result may be reduced by shortening the period of time between death and post mortem blood removal. PMID:29381929
Evaluating the efficacy of a chemistry video game
NASA Astrophysics Data System (ADS)
Shapiro, Marina
A quasi-experimental design pre-test/post-test intervention study utilizing a within group analysis was conducted with 45 undergraduate college chemistry students that investigated the effect of implementing a game-based learning environment into an undergraduate college chemistry course in order to learn if serious educational games (SEGs) can be used to achieve knowledge gains of complex chemistry concepts and to achieve increase in students' positive attitude toward chemistry. To evaluate if students learn chemistry concepts by participating in a chemistry game-based learning environment, a one-way repeated measures analysis of variance (ANOVA) was conducted across three time points (pre-test, post-test, delayed post-test which were chemistry content exams). Results showed that there was an increase in exam scores over time. The results of the ANOVA indicated a statistically significant time effect. To evaluate if students' attitude towards chemistry increased as a result of participating in a chemistry game-based learning environment a paired samples t-test was conducted using a chemistry attitudinal survey by Mahdi (2014) as the pre- and post-test. Results of the paired-samples t-test indicated that there was no significant difference in pre-attitudinal scores and post-attitudinal scores.
Maggio, Maria Cristina; Corsello, Giovanni; Messina, Giuseppe; Iovane, Angelo; Palma, Antonio
2017-01-01
Background: Juvenile idiopathic arthritis is a main cause of physical disability and has high economic costs for society. The purpose of this study was to assess the fitness levels and the postural and balance deficits with a specific test battery. Methods: Fifty-six subjects were enrolled in this study. Thirty-nine healthy subjects were included in the control group and seventeen in the juvenile idiopathic arthritis group. All subjects were evaluated using a posturography system. The fitness level was evaluated with a battery of tests (Abalakov test, sit-up test, hand grip test, backsaver sit and reach, the toe touch test). An unpaired t-test was used to determine differences. Pearson’s correlation coefficient was used to evaluate the correlation between the tests. Results: The battery of tests demonstrated that subjects in the juvenile idiopathic arthritis group have lower fitness levels compared to the control group. The juvenile idiopathic arthritis group showed low postural control with respect to the control group. Pearson analysis of the juvenile idiopathic arthritis group data showed significant correlations between variables. Pearson’s results from the control group data showed a similar trend. Conclusions: The results suggest that the battery of tests used could be an appropriate tool. However, we highlight that these conclusions need to be supported by other studies with a larger population scale. PMID:28753965
Patti, Antonino; Maggio, Maria Cristina; Corsello, Giovanni; Messina, Giuseppe; Iovane, Angelo; Palma, Antonio
2017-07-19
Background: Juvenile idiopathic arthritis is a main cause of physical disability and has high economic costs for society. The purpose of this study was to assess the fitness levels and the postural and balance deficits with a specific test battery. Methods: Fifty-six subjects were enrolled in this study. Thirty-nine healthy subjects were included in the control group and seventeen in the juvenile idiopathic arthritis group. All subjects were evaluated using a posturography system. The fitness level was evaluated with a battery of tests (Abalakov test, sit-up test, hand grip test, backsaver sit and reach, the toe touch test). An unpaired t -test was used to determine differences. Pearson's correlation coefficient was used to evaluate the correlation between the tests. Results: The battery of tests demonstrated that subjects in the juvenile idiopathic arthritis group have lower fitness levels compared to the control group. The juvenile idiopathic arthritis group showed low postural control with respect to the control group. Pearson analysis of the juvenile idiopathic arthritis group data showed significant correlations between variables. Pearson's results from the control group data showed a similar trend. Conclusions: The results suggest that the battery of tests used could be an appropriate tool. However, we highlight that these conclusions need to be supported by other studies with a larger population scale.
Evaluation of scanning earth sensor mechanism on engineering test satellite 4
NASA Technical Reports Server (NTRS)
Ikeuchi, M.; Wakabayashi, Y.; Ohkami, Y.; Kida, T.; Ishigaki, T.; Matsumoto, M.
1983-01-01
The results of the analysis and the evaluation of flight data obtained from the horizon sensor test project are described. The rotary mechanism of the scanning earth sensor composed of direct drive motor and bearings using solid lubricant is operated satisfactorily. The transmitted flight data from Engineering Test Satellite IV was evaluated in comparison with the design value.
TRAC-PD2 posttest analysis of the CCTF Evaluation-Model Test C1-19 (Run 38). [PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Motley, F.
The results of a Transient Reactor Analysis Code posttest analysis of the Cylindral Core Test Facility Evaluation-Model Test agree very well with the results of the experiment. The good agreement obtained verifies the multidimensional analysis capability of the TRAC code. Because of the steep radial power profile, the importance of using fine noding in the core region was demonstrated (as compared with poorer results obtained from an earlier pretest prediction that used a coarsely noded model).
Quantitative evaluation research of glare from automotive headlamps
NASA Astrophysics Data System (ADS)
Wang, Tiecheng; Qian, Rui; Cao, Ye; Gao, Mingqiu
2018-01-01
This study concerns the quantized evaluation research of glare from automotive headlamps. In the actual regulations, only one point in the test screen is set for judging whether driver can bear the light caused by headlamps of opposing vehicle. To evaluating practical effect of glare, we accept a glare zone with the probability distribution information of the oncoming driver's eye position. In this focus area, glare level of headlamp is represented by weighted luminous flux. To confirm the most comfortable illuminance value to human eyes at 50 m, we used test point B50L as observation position, and collected 1,000 subjective evaluation data from 20 test personnel in different ages during two months. Basing on the assessment results, we calculated 0.60 lx as recommended value for standardized testing procedure at 25 m. Then we figured out 0.38 lm as optimum value, and 0.25 / 1.20 lm as limiting values depending on regulations. We tested 40 sample vehicles with different levels to verify the sectional nonlinear quantitative evaluation method we designed, and analyzed the typical test results.
The "Anatomy" of a Performance-Enhancing Drug Test in Sports
ERIC Educational Resources Information Center
Werner, T. C.
2012-01-01
The components of a performance-enhancing drug (PED) test in sports include sample selection, collection, establishing sample integrity, sample pretreatment, analyte detection, data evaluation, reporting results, and action taken based on the result. Undergraduate curricula generally focus on the detection and evaluation steps of an analytical…
Groher, Michael E; Crary, Michael A; Carnaby Mann, Giselle; Vickers, Zata; Aguilar, Carlos
2006-10-01
Numerous studies have suggested that the clinical evaluation of swallowing fails to adequately identify those patients who aspirate or do not aspirate on a videofluoroscopic swallowing examination. These conclusions, however, are based on comparisons between swallowed materials that were not rheologically matched. The present study used a battery of rheologically matched test materials, involving thin and thick liquids and cohesive and adhesive semisolids. Using these test items, results from a clinical swallow evaluation were compared to the results of a videofluorographic evaluation using identical test materials. Results suggest that the use of three test materials, including thin and thick liquids given in volumes of 5 and 10 ml, demonstrated the strongest associations between cough on the clinical examination and aspiration on the videofluoroscopic examination.
Extra-Vehicular Activity (EVA) glove evaluation test protocol
NASA Technical Reports Server (NTRS)
Hinman-Sweeney, E. M.
1994-01-01
One of the most critical components of a space suit is the gloves, yet gloves have traditionally presented significant design challenges. With continued efforts at glove development, a method for evaluating glove performance is needed. This paper presents a pressure-glove evaluation protocol. A description of this evaluation protocol, and its development is provided. The protocol allows comparison of one glove design to another, or any one design to bare-handed performance. Gloves for higher pressure suits may be evaluated at current and future design pressures to drive out differences in performance due to pressure effects. Using this protocol, gloves may be evaluated during design to drive out design problems and determine areas for improvement, or fully mature designs may be evaluated with respect to mission requirements. Several different test configurations are presented to handle these cases. This protocol was run on a prototype glove. The prototype was evaluated at two operating pressures and in the unpressurized state, with results compared to bare-handed performance. Results and analysis from this test series are provided, as is a description of the configuration used for this test.
Evaluation of the fluorescent gonococcal test-heated.
Gaafar, H A
1976-01-01
In a 1-year evaluation of the indirect fluorescent antibody test for gonorrhea, 16,127 specimens from low-and high-risk groups were examined, and the results were compared with culture, history of exposure to a known patient, and clinical signs and symptoms. The results confirmed the usefulness of the indirect fluorescent antibody test for gonorrhea as a screening procedure, especially for women in the low-risk group. The test is more economic and probably more sensitive than culture for mass screening of asymptomatic women. PMID:791965
The effects of non-evaluative feedback on drivers' self-evaluation and performance.
Dogan, Ebru; Steg, Linda; Delhomme, Patricia; Rothengatter, Talib
2012-03-01
Drivers' tend to overestimate their competences, which may result in risk taking behavior. Providing drivers with feedback has been suggested as one of the solutions to overcome drivers' inaccurate self-evaluations. In practice, many tests and driving simulators provide drivers with non-evaluative feedback, which conveys information on the level of performance but not on what caused the performance. Is this type of feedback indeed effective in reducing self-enhancement biases? The current study aimed to investigate the effect of non-evaluative performance feedback on drivers' self-evaluations using a computerized hazard perception test. A between-subjects design was used with one group receiving feedback on performance in the hazard perception test while the other group not receiving any feedback. The results indicated that drivers had a robust self-enhancement bias in their self-evaluations regardless of the presence of performance feedback and that they systematically estimated their performance to be higher than they actually achieved in the test. Furthermore, they devalued the credibility of the test instead of adjusting their self-evaluations in order to cope with the negative feelings following the failure feedback. We discuss the theoretical and practical implications of these counterproductive effects of non-evaluative feedback. Copyright © 2011 Elsevier Ltd. All rights reserved.
Engineering evaluation of 24 channel multispectral scanner. [from flight tests
NASA Technical Reports Server (NTRS)
Lambeck, P. F.
1973-01-01
The results of flight tests to evaluate the performance of the 24 channel multispectral scanner are reported. The flight plan and test site are described along with the time response and channel registration. The gain and offset drift, and moire patterns are discussed. Aerial photographs of the test site are included.
Teaching Study Skills and Test-Taking Strategies to Elementary School Students.
ERIC Educational Resources Information Center
Beidel, Deborah C.; Turner, Samuel M.; Taylor-Ferreira, Jill C.
1999-01-01
Presents and evaluates a pilot program to reduce test anxiety and related social-evaluative concerns. The Testbusters program teaches effective study habits, study skills, and test-taking strategies for children in grades 4 through 7. Results indicate that Testbusters decreased general levels of test anxiety and improved overall grade point…
NASA Technical Reports Server (NTRS)
1981-01-01
The Sunmaster DEC 8A Large Manifold solar collector using simulated conditions was evaluated. The collector provided 17.17 square feet of gross collector area. Test conditions, test requirements, an analysis of results, and tables of test data are reported.
Kunkle, Gerald A.
2018-01-31
Two identical Radar Stage Sensors from Forest Technology Systems were evaluated to determine if they are suitable for U.S. Geological Survey (USGS) hydrologic data collection. The sensors were evaluated in laboratory conditions to evaluate the distance accuracy of the sensor over the manufacturer’s specified operating temperatures and distance to water ranges. Laboratory results were compared to the manufacturer’s accuracy specification of ±0.007 foot (ft) and the USGS Office of Surface Water (OSW) policy requirement that water-level sensors have a measurement uncertainty of no more than 0.01 ft or 0.20 percent of the indicated reading. Both of the sensors tested were within the OSW policy requirement in both laboratory tests and within the manufacturer’s specification in the distance to water test over tested distances from 3 to 15 ft. In the temperature chamber test, both sensors were within the manufacturer’s specification for more than 90 percent of the data points collected over a temperature range of –40 to +60 degrees Celsius at a fixed distance of 8 ft. One sensor was subjected to an SDI-12 communication test, which it passed. A field test was conducted on one sensor at a USGS field site near Landon, Mississippi, from February 5 to March 29, 2016. Water-level measurements made by the radar during the field test were in agreement with those made by the Sutron Accubar Constant Flow Bubble Gauge.Upon the manufacturer’s release of updated firmware version 1.09, additional SDI-12 and temperature testing was performed to evaluate added SDI-12 functions and verify that performance was unaffected by the update. At this time, an Axiom data logger is required to perform a firmware update on this sensor. The data confirmed the results of the original test. Based on the test results, the Radar Stage Sensor is a suitable choice for USGS hydrologic data collection.
NASA Astrophysics Data System (ADS)
Deng, Qihuang; Fan, Yuchi; Wang, Lianjun; Xiong, Zhi; Wang, Hongzhi; Li, Yaogang; Zhang, Qinghong; Kawasaki, Akira; Jiang, Wan
2012-01-01
Pb(Zr,Ti)O3 (PZT) ceramics were prepared by the conventional mixed oxide method, and the strength of the resultant PZT ceramics was evaluated using modified small punch (MSP) tests. Load-displacement curve test results showed that the crack-initiation and fracture strengths of PZT ceramics decreased after polarization. The effect of the polarization accelerated the fatigue properties of PZT ceramics. Scanning electron microscopy (SEM) results showed that microcracks were formed before the maximum load in the MSP test, and the first load drop corresponded to crack initiation.
Palmer, Christina G S; Boudreault, Patrick; Baldwin, Erin E; Sinsheimer, Janet S
2014-01-01
Using a prospective, longitudinal study design, this paper addresses the impact of genetic counseling and testing for deafness on deaf adults and the Deaf community. This study specifically evaluated the effect of genetic counseling and Connexin-26 and Connexin-30 genetic test results on participants' deaf identity and understanding of their genetic test results. Connexin-26 and Connexin-30 genetic testing was offered to participants in the context of linguistically and culturally appropriate genetic counseling. Questionnaire data collected from 209 deaf adults at four time points (baseline, immediately following pre-test genetic counseling, 1-month following genetic test result disclosure, and 6-months after result disclosure) were analyzed. Four deaf identity orientations (hearing, marginal, immersion, bicultural) were evaluated using subscales of the Deaf Identity Development Scale-Revised. We found evidence that participants understood their specific genetic test results following genetic counseling, but found no evidence of change in deaf identity based on genetic counseling or their genetic test results. This study demonstrated that culturally and linguistically appropriate genetic counseling can improve deaf clients' understanding of genetic test results, and the formation of deaf identity was not directly related to genetic counseling or Connexin-26 and Connexin-30 genetic test results.
NASA Technical Reports Server (NTRS)
Putnam, Jacob P.; Untaroiu, Costin; Somers. Jeffrey
2014-01-01
In an effort to develop occupant protection standards for future multipurpose crew vehicles, the National Aeronautics and Space Administration (NASA) has looked to evaluate the test device for human occupant restraint with the modification kit (THOR-K) anthropomorphic test device (ATD) in relevant impact test scenarios. With the allowance and support of the National Highway Traffic Safety Administration, NASA has performed a series of sled impact tests on the latest developed THOR-K ATD. These tests were performed to match test conditions from human volunteer data previously collected by the U.S. Air Force. The objective of this study was to evaluate the THOR-K finite element (FE) model and the Total HUman Model for Safety (THUMS) FE model with respect to the tests performed. These models were evaluated in spinal and frontal impacts against kinematic and kinetic data recorded in ATD and human testing. Methods: The FE simulations were developed based on recorded pretest ATD/human position and sled acceleration pulses measured during testing. Predicted responses by both human and ATD models were compared to test data recorded under the same impact conditions. The kinematic responses of the models were quantitatively evaluated using the ISO-metric curve rating system. In addition, ATD injury criteria and human stress/strain data were calculated to evaluate the risk of injury predicted by the ATD and human model, respectively. Results: Preliminary results show well-correlated response between both FE models and their physical counterparts. In addition, predicted ATD injury criteria and human model stress/strain values are shown to positively relate. Kinematic comparison between human and ATD models indicates promising biofidelic response, although a slightly stiffer response is observed within the ATD. Conclusion: As a compliment to ATD testing, numerical simulation provides efficient means to assess vehicle safety throughout the design process and further improve the design of physical ATDs. The assessment of the THOR-K and THUMS FE models in a spaceflight testing condition is an essential first step to implementing these models in the computational evaluation of spacecraft occupant safety. Promising results suggest future use of these models in the aerospace field.
Evaluation of LOINC for Representing Constitutional Cytogenetic Test Result Reports
Heras, Yan Z.; Mitchell, Joyce A.; Williams, Marc S.; Brothman, Arthur R.; Huff, Stanley M.
2009-01-01
Genetic testing is becoming increasingly important to medical practice. Integrating genetics and genomics data into electronic medical records is crucial in translating genetic discoveries into improved patient care. Information technology, especially Clinical Decision Support Systems, holds great potential to help clinical professionals take full advantage of genomic advances in their daily medical practice. However, issues relating to standard terminology and information models for exchanging genetic testing results remain relatively unexplored. This study evaluates whether the current LOINC standard is adequate to represent constitutional cytogenetic test result reports using sample result reports from ARUP Laboratories. The results demonstrate that current standard terminology is insufficient to support the needs of coding cytogenetic test results. The terminology infrastructure must be developed before clinical information systems will be able to handle the high volumes of genetic data expected in the near future. PMID:20351857
Evaluation of LOINC for representing constitutional cytogenetic test result reports.
Heras, Yan Z; Mitchell, Joyce A; Williams, Marc S; Brothman, Arthur R; Huff, Stanley M
2009-11-14
Genetic testing is becoming increasingly important to medical practice. Integrating genetics and genomics data into electronic medical records is crucial in translating genetic discoveries into improved patient care. Information technology, especially Clinical Decision Support Systems, holds great potential to help clinical professionals take full advantage of genomic advances in their daily medical practice. However, issues relating to standard terminology and information models for exchanging genetic testing results remain relatively unexplored. This study evaluates whether the current LOINC standard is adequate to represent constitutional cytogenetic test result reports using sample result reports from ARUP Laboratories. The results demonstrate that current standard terminology is insufficient to support the needs of coding cytogenetic test results. The terminology infrastructure must be developed before clinical information systems will be able to handle the high volumes of genetic data expected in the near future.
Tribble, David R.; Baqar, Shahida; Pang, Lorrin W.; Mason, Carl; Houng, Huo-Shu H.; Pitarangsi, Chittima; Lebron, Carlos; Armstrong, Adam; Sethabutr, Orntipa; Sanders, John W.
2008-01-01
High rates of Campylobacter fluoroquinolone resistance highlight the need to evaluate diagnostic strategies that can be used to assist with clinical management. Diagnostic tests were evaluated with U.S. soldiers presenting with acute diarrhea during deployment in Thailand. The results of bedside and field laboratory diagnostic tests were compared to stool microbiology findings for 182 enrolled patients. Campylobacter jejuni was isolated from 62% of the cases. Clinical and laboratory findings at the time of presentation were evaluated to determine their impact on the posttest probability, defined as the likelihood of a diagnosis of Campylobacter infection. Clinical findings, the results of tests for inflammation (stool occult blood testing [Hemoccult], fecal leukocytes, fecal lactoferrin, plasma C-reactive protein), and the numbers of Campylobacter-specific antibody-secreting cells in peripheral blood failed to increase the posttest probability above 90% in this setting of Campylobacter hyperendemicity when these findings were present. Positive results by a Campylobacter-specific commercial enzyme immunoassay (EIA) and, less so, a research PCR were strong positive predictors. The negative predictive value for ruling out Campylobacter infection, defined as a posttest probability of less than 10%, was similarly observed with these Campylobacter-specific stool-based tests as well the fecal leukocyte test. Compared to the other tests evaluated, the Campylobacter EIA is a sensitive and specific rapid diagnostic test that may assist with diagnostic evaluation, with consideration of the epidemiological setting, logistics, and cost. PMID:18234869
Use of Commercial FPGA-Based Evaluation Boards for Single-Event Testing of DDR2 and DDR3 SDRAMs
NASA Technical Reports Server (NTRS)
Ladbury, R. L.; Berg, M. D.; Wilcox, E. P.; LaBel, K. A.; Kim, H. S.; Phan, A. M.; Seidleck, C. M.
2013-01-01
We investigate the use of commercial FPGA based evaluation boards for radiation testing DDR2 and DDR3 SDRAMs. We evaluate the resulting data quality and the tradeoffs involved in the use of these boards.
Rota, Cristina; Biondi, Marco; Trenti, Tommaso
2011-09-26
Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and creatinine determination. The two instruments have demonstrated comparable performances: precision and correlation between instruments and strips, evaluated for chemical-physical parameters, were always good. Furthermore, accuracy was always very good: results of protein and glucose semi-quantitative measurements resulted to be highly correlated with those obtained by quantitative methods. Moreover, the semi-quantitative measurements of creatinine, employing Aution Sticks 10PA urine strips, were highly comparable with quantitative results. 10PA urine strips are eligible for urine creatinine determination with the possibility of correcting urinalysis results for urinary creatinine concentration, whenever necessary and calculating the protein creatinine ratio. Further studies should be carried out to evaluate effectiveness and appropriateness of the usage of creatinine semi-quantitative analysis.
Penicillin skin testing in the evaluation and management of penicillin allergy.
Fox, Stephanie; Park, Miguel A
2011-01-01
to review the role of penicillin skin testing in the evaluation and management of penicillin allergy mediated by IgE. PubMed and OVID search of English-language articles regarding penicillin allergy, penicillin allergy testing, and management of penicillin allergy. articles pertinent to the subject matter were selected and reviewed. the major determinant (benzylpenicillin polylysine) detects the greatest number of penicillin allergic patients during skin testing, and the minor determinants of penicillin increase the sensitivity of penicillin skin testing. Penicillin skin testing to the major and minor determinants was found to have a negative predictive value of 97% to 99%. The incidence of systemic adverse reaction to penicillin skin testing is less than 1%. a detailed history of the prior reaction to penicillin is an integral part of the evaluation, but it is not accurate in predicting a positive penicillin skin test result. A patient with a negative penicillin skin test result to the major and minor determinants is at a low risk of an immediate-type hypersensitivity reaction to penicillin. Patients with a positive skin test result should undergo desensitization to penicillin or an alternative antibiotic should be considered.
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2011 CFR
2011-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2014 CFR
2014-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2013 CFR
2013-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2010 CFR
2010-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2012 CFR
2012-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Darren M.
Sandia National Laboratories has tested and evaluated Geotech Smart24 data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Geotech Smart24 digitizer with a Fortezza PCMCIA cryptomore » card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy, analog bandwidth and calibrator performance.« less
NASA Technical Reports Server (NTRS)
Ray, Ronald J.
1994-01-01
New flight test maneuvers and analysis techniques for evaluating the dynamic response of in-flight thrust models during throttle transients have been developed and validated. The approach is based on the aircraft and engine performance relationship between thrust and drag. Two flight test maneuvers, a throttle step and a throttle frequency sweep, were developed and used in the study. Graphical analysis techniques, including a frequency domain analysis method, were also developed and evaluated. They provide quantitative and qualitative results. Four thrust calculation methods were used to demonstrate and validate the test technique. Flight test applications on two high-performance aircraft confirmed the test methods as valid and accurate. These maneuvers and analysis techniques were easy to implement and use. Flight test results indicate the analysis techniques can identify the combined effects of model error and instrumentation response limitations on the calculated thrust value. The methods developed in this report provide an accurate approach for evaluating, validating, or comparing thrust calculation methods for dynamic flight applications.
NASA Technical Reports Server (NTRS)
Wilson, D. J.; Krause, M. C.; Craven, C. E.; Edwards, B. B.; Coffey, E. W.; Huang, C. C.; Jetton, J. L.; Morrison, L. K.
1974-01-01
A program plan for system evaluation of the two-dimensional Scanning Laser Doppler System (SLDS) is presented. In order to meet system evaluation and optimization objectives the following tests were conducted: (1) noise tests; (2) wind tests; (3) blower flowfield tests; (4) single unit (1-D) flyby tests; and (5) dual unit (2-D) flyby tests. Test results are reported. The final phase of the program included logistics preparation, equipment interface checkouts, and data processing. It is concluded that the SLDS is capable of accurately tracking aircraft wake vortices from small or large aircraft, and in any type of weather.
Comprehension and Data-Sharing Behavior of Direct-To-Consumer Genetic Test Customers.
McGrath, Scott P; Coleman, Jason; Najjar, Lotfollah; Fruhling, Ann; Bastola, Dhundy R
2016-01-01
The aim of this study was to evaluate current direct-to-consumer (DTC) genetic customers' ability to interpret and comprehend test results and to determine if honest brokers are needed. One hundred and twenty-two customers of the DTC genetic testing company 23andMe were polled in an online survey. The subjects were asked about their personal test results and to interpret the results of two mock test cases (type 2 diabetes and multiple sclerosis), where results were translated into disease probability for an individual compared to the public. When asked to evaluate the risk, 72.1% correctly assessed the first case and 77% were correct on the second case. Only 23.8% of those surveyed were able to interpret both cases correctly. x03C7;2 and logistic regression were used to interpret the results. Participants who took the time to read the DTC test-provided supplemental material were 3.93 times (p = 0.040) more likely to correctly interpret the test results than those who did not. The odds for correctly interpreting the test cases were 3.289 times (p = 0.011) higher for those who made more than USD 50,000 than those who made less. Survey results were compared to the Health Information National Trends Survey (HINTS) phase 4 cycle 3 data to evaluate national trends. Most of the subjects were able to correctly interpret the test cases, yet a majority did not share their results with a health-care professional. As the market for DTC genetic testing grows, test comprehension will become more critical. Involving more health professionals in this process may be necessary to ensure proper interpretations. © 2016 S. Karger AG, Basel.
Ueno, Tamio; Matuda, Junichi; Yamane, Nobuhisa
2013-03-01
To evaluate the occurrence of out-of acceptable ranges and accuracy of antimicrobial susceptibility tests, we applied a new statistical tool to the Inter-Laboratory Quality Control Program established by the Kyushu Quality Control Research Group. First, we defined acceptable ranges of minimum inhibitory concentration (MIC) for broth microdilution tests and inhibitory zone diameter for disk diffusion tests on the basis of Clinical and Laboratory Standards Institute (CLSI) M100-S21. In the analysis, more than two out-of acceptable range results in the 20 tests were considered as not allowable according to the CLSI document. Of the 90 participating laboratories, 46 (51%) experienced one or more occurrences of out-of acceptable range results. Then, a binomial test was applied to each participating laboratory. The results indicated that the occurrences of out-of acceptable range results in the 11 laboratories were significantly higher when compared to the CLSI recommendation (allowable rate < or = 0.05). The standard deviation indices(SDI) were calculated by using reported results, mean and standard deviation values for the respective antimicrobial agents tested. In the evaluation of accuracy, mean value from each laboratory was statistically compared with zero using a Student's t-test. The results revealed that 5 of the 11 above laboratories reported erroneous test results that systematically drifted to the side of resistance. In conclusion, our statistical approach has enabled us to detect significantly higher occurrences and source of interpretive errors in antimicrobial susceptibility tests; therefore, this approach can provide us with additional information that can improve the accuracy of the test results in clinical microbiology laboratories.
A performance evaluation of various coatings, substrate materials, and solar collector systems
NASA Technical Reports Server (NTRS)
Dolan, F. J.
1976-01-01
An experimental apparatus was constructed and utilized in conjunction with both a solar simulator and actual sunlight to test and evaluate various solar panel coatings, panel designs, and scaled-down collector subsystems. Data were taken by an automatic digital data acquisition system and reduced and printed by a computer system. The solar collector test setup, data acquisition system, and data reduction and printout systems were considered to have operated very satisfactorily. Test data indicated that there is a practical or useful limit in scaling down beyond which scaled-down testing cannot produce results comparable to results of larger scale tests. Test data are presented as are schematics and pictures of test equipment and test hardware.
Indoor test for thermal performance evaluation of the Solaron (air) solar collector
NASA Technical Reports Server (NTRS)
1978-01-01
The test procedure used and the results obtained from an evaluation test program, conducted to obtain thermal performance data on a Solaron double glazed air solar collector under simulated conditions in a solar simulator are described. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed. The Solaron collector absorber plate is made of 24-gage steel, the coating is baked-on black paint, the cover consists of two sheets of 1/8-inch low-iron tempered glass, and the insulation is one thickness of 3 5/8-inch fiberglass batting.
Dupont, S; De Spiegeleer, A; Liu, D J X; Lefère, L; van Doorn, D A; Hesta, M
2016-01-01
Commercial immunoglobulin E (IgE)-based tests are available for diagnosis of food allergies and are commonly used in equine practice. However, these tests have been proven unreliable as a screening method in man and other species, but not critically evaluated in equids. Therefore, a commercially available IgE-based test for horses was evaluated. To evaluate the consistency of the results obtained with a commercially available IgE-based test for food allergy diagnosis in ponies (Phase I) and to subject ponies to a provocation trial with the presumed allergens (Phase II). Allergen screening followed by experimental food provocation trials in healthy ponies. Blood samples of 17 healthy Shetland ponies were taken at 2 different time points, sent blinded to a commercial laboratory for screening of common food allergens and the results were evaluated for consistency (Phase I). Ponies that were positive for food allergens were consecutively challenged orally with each allergen separately for 14 days (Phase II). A washout period of one week was applied in ponies with multiple positive results. Clinical parameters and serum amyloid A were monitored during the provocation trial. Only 7/17 ponies were negative on the IgE-based test at the 2 time points, 3 had positive results twice but only one tested positive twice for the same food allergen. No abnormalities were noted during the provocation trials. This study demonstrated that this IgE-based test is not a reliable screening tool for food allergy in healthy equids. © 2015 EVJ Ltd.
Towards General Evaluation of Intelligent Systems: Lessons Learned from Reproducing AIQ Test Results
NASA Astrophysics Data System (ADS)
Vadinský, Ondřej
2018-03-01
This paper attempts to replicate the results of evaluating several artificial agents using the Algorithmic Intelligence Quotient test originally reported by Legg and Veness. Three experiments were conducted: One using default settings, one in which the action space was varied and one in which the observation space was varied. While the performance of freq, Q0, Qλ, and HLQλ corresponded well with the original results, the resulting values differed, when using MC-AIXI. Varying the observation space seems to have no qualitative impact on the results as reported, while (contrary to the original results) varying the action space seems to have some impact. An analysis of the impact of modifying parameters of MC-AIXI on its performance in the default settings was carried out with the help of data mining techniques used to identifying highly performing configurations. Overall, the Algorithmic Intelligence Quotient test seems to be reliable, however as a general artificial intelligence evaluation method it has several limits. The test is dependent on the chosen reference machine and also sensitive to changes to its settings. It brings out some differences among agents, however, since they are limited in size, the test setting may not yet be sufficiently complex. A demanding parameter sweep is needed to thoroughly evaluate configurable agents that, together with the test format, further highlights computational requirements of an agent. These and other issues are discussed in the paper along with proposals suggesting how to alleviate them. An implementation of some of the proposals is also demonstrated.
Computerized Adaptive Performance Evaluation.
1980-02-01
based on classical psychological test theory, with the result that the obtained measurements ani statements of achievement or performance have... psychological aspects of the achievement testing environment. Results , C Applications of Item Characteristic Curve Models and Adaptive Testing Strategies ICC...of immediate knowledge of results and adaptive testing on ability test performance (Research Report 76-4). Minneapolis: Department of Psychology
Calibrating and Evaluating Boomless Spray Systems for Applying Forest Herbicides
Michael A. Wehr; Russell W. Johnson; Robert L. Sajdak
1985-01-01
Describes a testing procedure used to calibrate and evaluate agricultureal boomless spray systems. Tests allow the user to obtain dependable and satisfactory results when used in actual forest situations.
Evaluation of Surface Infiltration Testing Procedures in Permeable Pavement Systems
The ASTM method (ASTM C1701) for measuring infiltration rate of in-place pervious concrete provides limited guidance on how to select testing locations, so research is needed to evaluate how testing sites should be selected and how results should be interpreted to assess surface ...
Benefits of Multiple Methods for Evaluating HIV Counseling and Testing Sites in Pennsylvania.
ERIC Educational Resources Information Center
Encandela, John A.; Gehl, Mary Beth; Silvestre, Anthony; Schelzel, George
1999-01-01
Examines results from two methods used to evaluate publicly funded human immunodeficiency virus (HIV) counseling and testing in Pennsylvania. Results of written mail surveys of all sites and interviews from a random sample of 30 sites were similar in terms of questions posed and complementary in other ways. (SLD)
[Magnetic resonance compatibility research for coronary mental stents].
Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren
2015-01-01
The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.
NASA Technical Reports Server (NTRS)
Frickland, P. O.; Repar, J.
1982-01-01
A previously developed test design for accelerated aging of photovoltaic modules was experimentally evaluated. The studies included a review of relevant field experience, environmental chamber cycling of full size modules, and electrical and physical evaluation of the effects of accelerated aging during and after the tests. The test results indicated that thermally induced fatigue of the interconnects was the primary mode of module failure as measured by normalized power output. No chemical change in the silicone encapsulant was detectable after 360 test cycles.
Hueth, Kyle D; Jackson, Brian R; Schmidt, Robert L
2018-05-31
To evaluate the prevalence of potentially unnecessary repeat testing (PURT) and the associated economic burden for an inpatient population at a large academic medical facility. We evaluated all inpatient test orders during 2016 for PURT by comparing the intertest times to published recommendations. Potential cost savings were estimated using the Centers for Medicare & Medicaid Services maximum allowable reimbursement rate. We evaluated result positivity as a determinant of PURT through logistic regression. Of the evaluated 4,242 repeated target tests, 1,849 (44%) were identified as PURT, representing an estimated cost-savings opportunity of $37,376. Collectively, the association of result positivity and PURT was statistically significant (relative risk, 1.2; 95% confidence interval, 1.1-1.3; P < .001). PURT contributes to unnecessary health care costs. We found that a small percentage of providers account for the majority of PURT, and PURT is positively associated with result positivity.
Evaluation results of xTCA equipment for HEP experiments at CERN
NASA Astrophysics Data System (ADS)
Di Cosmo, M.; Bobillier, V.; Haas, S.; Joos, M.; Mico, S.; Vasey, F.; Vichoudis, P.
2013-12-01
The MicroTCA and AdvancedTCA industry standards are candidate modular electronic platforms for the upgrade of the current generation of high energy physics experiments. The PH-ESE group at CERN launched in 2011 the xTCA evaluation project with the aim of performing technical evaluations and eventually providing support for commercially available components. Different devices from different vendors have been acquired, evaluated and interoperability tests have been performed. This paper presents the test procedures and facilities that have been developed and focuses on the evaluation results including electrical, thermal and interoperability aspects.
ERIC Educational Resources Information Center
Puhan, Gautam; Boughton, Keith A.; Kim, Sooyeon
2005-01-01
The study evaluated the comparability of two versions of a teacher certification test: a paper-and-pencil test (PPT) and computer-based test (CBT). Standardized mean difference (SMD) and differential item functioning (DIF) analyses were used as measures of comparability at the test and item levels, respectively. Results indicated that effect sizes…
Flat panel display test and evaluation: procedures, standards, and facilities
NASA Astrophysics Data System (ADS)
Jackson, Timothy W.; Daniels, Reginald; Hopper, Darrel G.
1997-07-01
This paper addresses flat panel display test and evaluation via a discussion of procedures, standards and facilities. Procedures need to be carefully developed and documented to ensure that test accomplished in separate laboratories produce comparable results. The tests themselves must not be a source of inconsistency in test results when such comparisons are made in the course of procurements or new technology prototype evaluations. Standards are necessary to expedite the transition of the new display technologies into applications and to lower the costs of custom parts applied across disparate applications. The flat panel display industry is in the course of ascertaining and formulating such standards as they are of value to designers, manufacturers, marketers and users of civil and military products and equipment. Additionally, in order to inform the DoD and industry, the test and evaluation facilities of the Air Force Research Laboratory Displays Branch are described. These facilities are available to support procurements involving flat panel displays and to examine new technology prototypes. Finally, other government display testing facilities within the Navy and the Army are described.
GICHD Mine Dog Testing Project - Soil Sample Results No.3
DOE Office of Scientific and Technical Information (OSTI.GOV)
PHELAN, JAMES M.; BARNETT, JAMES L.; BENDER, SUSAN FAE ANN
2003-03-01
A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performancemore » and seasonal weather conditions. This report documents the analytical chemical methods and results from the third batch of soils received. This batch contained samples from Kharga, Afghanistan collected in October 2002.« less
GICHD mine dog testing project : soil sample results #5.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.
2004-01-01
A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonalmore » weather conditions. This report documents the analytical chemical methods and results from the fifth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in June 2003.« less
The Behind-the-Knee test: an efficient model for evaluating mechanical and chemical irritation.
Farage, Miranda A
2006-05-01
The 'Behind-the-Knee' method (BTK test), using the popliteal fossa as a test site, evaluates both the inherent chemical irritation, and the potential for mechanical irritation of substrates and products. This approach eliminates some of the difficulties of in-use clinical test systems while still providing reliable results. In this publication, examples of the results of BTK tests on several materials are presented with direct comparisons, where possible, with results of in-use clinical testing conducted on the same materials. In in-use clinical tests, volunteer panelists were provided with catamenial products to use in place of their normal product. In the BTK test, samples were applied daily to the popliteal fossa using an elastic athletic band. In both studies, irritation reactions were scored visually. Levels of irritation in the BTK test are consistently higher than those of standard patch tests, illustrating the contribution of mechanical irritation to the overall irritant potential of materials and products. Repeated tests on identical test materials demonstrated that the BTK test results are reproducible. Side-by-side comparisons of the BTK test and in-use clinical tests demonstrated that the BTK test produces results of similar quality to the in-use clinical. By using several concurrent panels with a common test material, it is possible to compare the irritant properties of several materials at once. We have tested over 25 different materials in over 35 BTK studies. The test method has proven reliable and versatile in testing a wide variety of materials, including menstrual pads, topsheets, interlabial pads, pantiliners, tampons and lotion coatings on products. Unlike in-use clinicals, the BTK test allows the direct comparison of two products at one time on the same individual, and is easily adapted to investigative programs. It is subject to fewer confounding factors, is much easier to implement, has a shorter turnaround time, and is less expensive than in-use clinical testing. Importantly, unlike standard patch tests, the BTK test evaluates both the inherent chemical irritation associated with materials and the mechanical irritation owing to friction. Although the BTK test was developed using catamenial products, the test system provides a valuable alternative for evaluating any material where mechanical irritation may play a role, including textiles, facial tissues, baby and adult diapers, and laundry products that may leave residues on fabrics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrow, A; Rangaraj, D; Perez-Andujar, A
2016-06-15
Purpose: This work’s objective is to determine the overlap of processes, in terms of sub-processes and time, between acceptance testing and commissioning of a conventional medical linear accelerator and to evaluate the time saved by consolidating the two processes. Method: A process map for acceptance testing for medical linear accelerators was created from vendor documentation (Varian and Elekta). Using AAPM TG-106 and inhouse commissioning procedures, a process map was created for commissioning of said accelerators. The time to complete each sub-process in each process map was evaluated. Redundancies in the processes were found and the time spent on each weremore » calculated. Results: Mechanical testing significantly overlaps between the two processes - redundant work here amounts to 9.5 hours. Many beam non-scanning dosimetry tests overlap resulting in another 6 hours of overlap. Beam scanning overlaps somewhat - acceptance tests include evaluating PDDs and multiple profiles but for only one field size while commissioning beam scanning includes multiple field sizes and depths of profiles. This overlap results in another 6 hours of rework. Absolute dosimetry, field outputs, and end to end tests are not done at all in acceptance testing. Finally, all imaging tests done in acceptance are repeated in commissioning, resulting in about 8 hours of rework. The total time overlap between the two processes is about 30 hours. Conclusion: The process mapping done in this study shows that there are no tests done in acceptance testing that are not also recommended to do for commissioning. This results in about 30 hours of redundant work when preparing a conventional linear accelerator for clinical use. Considering these findings in the context of the 5000 linacs in the United states, consolidating acceptance testing and commissioning would have allowed for the treatment of an additional 25000 patients using no additional resources.« less
Decruyenaere, M; Evers-Kiebooms, G; Boogaerts, A; Cassiman, J J; Cloostermans, T; Demyttenaere, K; Dom, R; Fryns, J P; Van den Berghe, H
1996-01-01
For people at risk for Huntington's disease, the anxiety and uncertainty about the future may be very burdensome and may be an obstacle to personal decision making about important life issues, for example, procreation. For some at risk persons, this situation is the reason for requesting predictive DNA testing. The aim of this paper is two-fold. First, we want to evaluate whether knowing one's carrier status reduces anxiety and uncertainty and whether it facilitates decision making about procreation. Second, we endeavour to identify pretest predictors of psychological adaptation one year after the predictive test (psychometric evaluation of general anxiety, depression level, and ego strength). The impact of the predictive test result was assessed in 53 subjects tested, using pre- and post-test psychometric measurement and self-report data of follow up interviews. Mean anxiety and depression levels were significantly decreased one year after a good test result; there was no significant change in the case of a bad test result. The mean personality profile, including ego strength, remained unchanged one year after the test. The study further shows that the test result had a definite impact on reproductive decision making. Stepwise multiple regression analyses were used to select the best predictors of the subject's post-test reactions. The results indicate that a careful evaluation of pretest ego strength, depression level, and coping strategies may be helpful in predicting post-test reactions, independently of the carrier status. Test result (carrier/ non-carrier), gender, and age did not significantly contribute to the prediction. About one third of the variance of post-test anxiety and depression level and more than half of the variance of ego strength was explained, implying that other psychological or social aspects should also be taken into account when predicting individual post-test reactions. PMID:8880572
Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings
Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V
2014-01-01
Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1975-01-01
An evaluation test program was conducted to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. Tests and results are described.
7 CFR 15b.24 - Evaluation and placement.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...
7 CFR 15b.24 - Evaluation and placement.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...
1981-1982 Evaluation Findings.
ERIC Educational Resources Information Center
Austin Independent School District, TX. Office of Research and Evaluation.
The findings in evaluation and testing activities of the Austin Independent School District (AISD) during the 1981-82 school year are summarized. The first section, "1982 at a Glance," discusses the evaluation findings as a whole. Final reports and abstracts of related reports on achievement test results are presented for the district…
7 CFR 15b.24 - Evaluation and placement.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...
7 CFR 15b.24 - Evaluation and placement.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...
EMISSION TEST REPORT, OMSS FIELD TEST ON CARBON INJECTION FOR MERCURY CONTROL
The report discusses results of a parametric evaluation of powdered activated carbon for control of mercury (Hg) emission from a municipal waste cornbustor (MWC) equipped with a lime spray dryer absorber/fabric filter (SD/FF). The primary test objectives were to evaluate the effe...
EVALUATION OF A TEST METHOD FOR MEASURING INDOOR AIR EMISSIONS FROM DRY-PROCESS PHOTOCOPIERS
A large chamber test method for measuring indoor air emissions from office equipment was developed, evaluated, and revised based on the initial testing of four dry-process photocopiers. Because all chambers may not necessarily produce similar results (e.g., due to differences in ...
Evaluation of a new computerized psychometric test battery: Effects of zolpidem and caffeine.
Pilli, Raveendranadh; Naidu, Mur; Pingali, Usharani; Shobha, Jc
2013-10-01
To evaluate the effects of centrally active drugs using a new indigenously developed automated psychometric test system and compare the results with that obtained using pencil- and paper-based techniques. The tests were standardized in 24 healthy participants. Reproducibility of the test procedure was evaluated by performing the tests by a single experimenter on two occasions (interday reproducibility). To evaluate the sensitivity of the tests, the effects of zolpidem (5 mg) and caffeine (500 mg) versus placebo were studied in 24 healthy participants in a randomized, double-blind three-way crossover design. Psychometric tests were performed at baseline and at 1, 2, and 3 h after administration of study medication. The effects of zolpidem and caffeine on the psychomotor performance were most pronounced 1 h after administration. At this time, a significant impairment of performance in the simple reaction test (SRT), choice discrimination test (CDT), digit symbol substitution test (DSST), digit vigilance test (DVT), and card sorting test (CST) was observed with zolpidem. In contrast, caffeine showed a significant improvement in performance in CDT and DVT only. The results suggest that the tests of the computerized system are more sensitive and reliable then the pencil and paper tests in detecting the effects of central acting agents and are suitable for use in clinical areas to conduct studies with patients.
77 FR 65553 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-29
... results; and (4)Information about post-test follow-ups, including notification of test result, post-test...) Monitoring and Evaluation System to collect standardized, non-identifying, client-level and test-level...-identifying information from funded grantees, including: (1) Information about test sites that provide HEPTLC...
77 FR 34952 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-12
... results; and (4) Information about post-test follow- ups, including notification of test result, post-test...) Monitoring and Evaluation System to collect standardized, non-identifying, client-level and test-level...-identifying information from funded grantees, including: (1) Information about test sites that provide HEPTLC...
Skylab parasol material evaluation
NASA Technical Reports Server (NTRS)
Jacobs, S.
1975-01-01
Results of experimental work to evaluate the degradation rate of a parasol that was used as a means of alleviating thermal problems encountered soon after the launch of the Skylab 1 space vehicle are presented. Material selection criteria are discussed; the material chosen is described, and results of tests performed after environmental exposure at five facilities are given. The facilities used for exposure to ultraviolet radiation/thermal-vacuum environments and the equipment used for testing physical properties before and after exposure are described. Comparisons of ground test and flight test data are included.
Palmer, Christina G. S.; Boudreault, Patrick; Baldwin, Erin E.; Sinsheimer, Janet S.
2014-01-01
Using a prospective, longitudinal study design, this paper addresses the impact of genetic counseling and testing for deafness on deaf adults and the Deaf community. This study specifically evaluated the effect of genetic counseling and Connexin-26 and Connexin-30 genetic test results on participants' deaf identity and understanding of their genetic test results. Connexin-26 and Connexin-30 genetic testing was offered to participants in the context of linguistically and culturally appropriate genetic counseling. Questionnaire data collected from 209 deaf adults at four time points (baseline, immediately following pre-test genetic counseling, 1-month following genetic test result disclosure, and 6-months after result disclosure) were analyzed. Four deaf identity orientations (hearing, marginal, immersion, bicultural) were evaluated using subscales of the Deaf Identity Development Scale-Revised. We found evidence that participants understood their specific genetic test results following genetic counseling, but found no evidence of change in deaf identity based on genetic counseling or their genetic test results. This study demonstrated that culturally and linguistically appropriate genetic counseling can improve deaf clients' understanding of genetic test results, and the formation of deaf identity was not directly related to genetic counseling or Connexin-26 and Connexin-30 genetic test results. PMID:25375116
DOT National Transportation Integrated Search
2016-08-01
The Federal Railroad Administration (FRA), Transportation Technology Center, Inc. (TTCI), and rail industry participants have : performed probability of detection (POD) assessments to evaluate nondestructive testing (NDT) technologies, which are : pr...
NASA Technical Reports Server (NTRS)
On, F. J.
1975-01-01
Test methods were evaluated to ascertain whether a spacecraft, properly tested within its shroud, could be vibroacoustic tested without the shroud, with adjustments made in the acoustic input spectra to simulate the acoustic response of the missing shroud. The evaluation was based on vibroacoustic test results obtained from a baseline model composed (1) of a spacecraft with adapter, lower support structure, and shroud; (2) of the spacecraft, adapter, and lower structure, but without the shroud; and (3) of the spacecraft and adapter only. Emphasis was placed on the magnitude of the acoustic input changes required to substitute for the shroud and the difficulty of making such input changes, and the degree of missimulation which can result from the performance of a particular, less-than optimum test. Conclusions are drawn on the advantages and disadvantages derived from the use of input spectra adjustment methods and lower support structure simulations. Test guidelines were also developed for planning and performing a launch acoustic-environmental test.
Villasís-Keever, Miguel Ángel; Rizzoli-Córdoba, Antonio; Delgado-Ginebra, Ismael; Mares-Serratos, Blanca Berenice; Martell-Valdez, Liliana; Sánchez-Velázquez, Olivia; Reyes-Morales, Hortensia; O'Shea-Cuevas, Gabriel; Aceves-Villagrán, Daniel; Carrasco-Mendoza, Joaquín; Antillón-Ocampo, Fátima Adriana; Villagrán-Muñoz, Víctor Manuel; Halley-Castillo, Elizabeth; Baqueiro-Hernández, César Iván; Pizarro-Castellanos, Mariel; Martain-Pérez, Itzamara Jacqueline; Palma-Tavera, Josuha Alexander; Vargas-López, Guillermo; Muñoz-Hernández, Onofre
The Child Development Evaluation (CDE) test designed and validated in Mexico has been used as a screening tool for developmental problems in primary care facilities across Mexico. Heterogeneous results were found among those states where these were applied, despite using the same standardized training model for application. The objective was to evaluate a supervision model for quality of application of the CDE test at primary care facilities. A study was carried out in primary care facilities from three Mexican states to evaluate concordance of the results between supervisor and primary care personnel who administered the test using two different methods: direct observation (shadow study) or reapplication of the CDE test (consistency study). There were 380 shadow studies applied to 51 psychologists. General concordance of the shadow study was 86.1% according to the supervisor: green 94.5%, yellow 73.2% and red 80.0%. There were 302 re-test evaluations with a concordance of 88.1% (n=266): green 96.8%, yellow 71.7% and red 81.8%. There were no differences between CDE test subgroups by age. Both shadow and re-test study were adequate for the evaluation of the quality of the administration of the CDE Test and may be useful as a model of supervision in primary care facilities. The decision of which test to use relies on the availability of supervisors. Copyright © 2015 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.
The progress test as a diagnostic tool for a new PBL curriculum.
Al Alwan, I; Al-Moamary, M; Al-Attas, N; Al Kushi, A; AlBanyan, E; Zamakhshary, M; Al Kadri, H M F; Tamim, H; Magzoub, M; Hajeer, A; Schmidt, H
2011-12-01
The College of Medicine at King Saud bin Abdulaziz University for Health Sciences (KSAU-HS) is running a PBL-based curriculum. A progress test was used to evaluate components of the basic medical and clinical sciences curriculum. To evaluate the performance of students at different levels of the college of medicine curriculum through USMLE-based test that focused on basic medical and clinical sciences topics. The USMLE-based basic medical and clinical sciences progress test has been conducted since 2007. It covers nine topics, including: anatomy; physiology; histology; epidemiology; biochemistry; behavioral sciences, pathology, pharmacology and immunology/microbiology. Here we analyzed results of three consecutive years of all students in years 1-4. There was a good correlation between progress test results and students' GPA. Progress test results in the clinical topics were better than basic medical sciences. In basic medical sciences, results of pharmacology, biochemistry, behavioral sciences and histology gave lower results than the other disciplines. Results of our progress test proved to be a useful indicator for both basic medical sciences and clinical sciences curriculum. Results are being utilized to help in modifying our curriculum.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rembold, Randy Kai; Hart, Darren M.
Sandia National Laboratories has tested and evaluated Geotech SMART24BH borehole data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of two Geotech SMART24BH digitizers with a Fortezza PCMCIAmore » crypto card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy/statistics/drift, analog bandwidth.« less
Fracture mechanics data for 2024-T861 and 2124-T851 aluminum
NASA Technical Reports Server (NTRS)
Pionke, L. J.; Linback, R. K.
1974-01-01
The fracture toughness and fatigue flaw growth characteristics of 2024-T861 and 2124-T851 aluminum were evaluated under plane stress conditions. Center cracked tension specimens were employed to evaluate these properties under a number of different test conditions which included variations in specimen thickness, specimen orientation, test environment, and initial flaw size. The effect of buckling was also investigated for all tests of thin gage specimens, and the effect of frequency and stress ratio was evaluated for the cyclic tests. Fracture toughness test results were analyzed and presented in terms of fracture resistance curves; fatigue flaw growth data was analyzed using empirical rate models. The results of the study indicate that both fracture toughness and resistance to fatigue crack growth improve with increasing temperature and decreasing thickness. The presence of buckling during testing of thin gage panels was found to degrade the resistance to fatigue flaw growth only at elevated temperatures.
Results and analysis of the switchyard impact tests
DOT National Transportation Integrated Search
1980-01-01
This report presents the results and analysis of series 3 through 7 and series 10 of the FRA/RPI/AAR Switchyard Impact Tests. The test results and analysis are used to evaluate the head shield and the shelf-E coupler as protective devices for hazardo...
Jeffries, Marlo K Sellin; Stultz, Amy E; Smith, Austin W; Rawlings, Jane M; Belanger, Scott E; Oris, James T
2014-11-01
An increased demand for chemical toxicity evaluations has resulted in the need for alternative testing strategies that address animal welfare concerns. The fish embryo toxicity (FET) test developed for zebrafish (Danio rerio) is one such alternative, and the application of the FET test to other species such as the fathead minnow (Pimephales promelas) has been proposed. In the present study, the performances of the FET test and the larval growth and survival (LGS; a standard toxicity testing method) test in zebrafish and fathead minnows were evaluated. This required that testing methods for the fathead minnow FET and zebrafish LGS tests be harmonized with existing test methods and that the performance of these testing strategies be evaluated by comparing the median lethal concentrations of 2 reference toxicants, 3,4-dicholoraniline and ammonia, obtained via each of the test types. The results showed that procedures for the zebrafish FET test can be adapted and applied to the fathead minnow. Differences in test sensitivity were observed for 3,4-dicholoraniline but not ammonia; therefore, conclusions regarding which test types offer the least or most sensitivity could not be made. Overall, these results show that the fathead minnow FET test has potential as an alternative toxicity testing strategy and that further analysis with other toxicants is warranted in an effort to better characterize the sensitivity and feasibility of this testing strategy. © 2014 SETAC.
The final days of Solar Max - Lessons learned from engineering evaluation tests
NASA Technical Reports Server (NTRS)
Donnelly, Michael L.; Croft, John W.; Ward, David K.; Thames, Michael A.
1990-01-01
End-of-life engineering evaluation tests were performed on Solar Max between October and November 1989. The tests included four-wheel control law operation; reaction wheel rundowns; modular power subsystem standard power regulator unit voltage-temperature level tests; battery rundown/2nd plateau determination; high gain antenna retraction and jettison; and solar array jettison. This paper presents these tests, their results, and the lessons learned from them.
Yun, Jun-Won; Hailian, Quan; Na, Yirang; Kang, Byeong-Cheol; Yoon, Jung-Hee; Cho, Eun-Young; Lee, Miri; Kim, Da-Eun; Bae, SeungJin; Seok, Seung Hyeok; Lim, Kyung-Min
2016-12-01
In an effort to explore the use of alternative methods to animal testing for the evaluation of the ocular irritancy of medical devices, we evaluated representative contact lenses with the bovine corneal opacity and permeability test (BCOP) and an in vitro eye irritation test using the three-dimensionally-reconstructed human corneal epithelium (RhCE) models, EpiOcular™ and MCTT HCE™. In addition, we compared the obtained results with the ISO standard in vivo rabbit eye irritation test (ISO10993-10). Along with the positive controls (benzalkonium chloride, BAK, 0.02, 0.2, and 1%), the extracts of 4 representative contact lenses (soft, disposable, hard, and colored lenses) and 2 reference lenses (dye-eluting and BAK-coated lenses) were tested. All the lenses, except for the BAK-coated lens, were determined non-irritants in all test methods, while the positive controls yielded relevant results. More importantly, BCOP, EpiOcular™, and MCTT HCE™ yielded a consistent decision for all the tested samples, with the exception of 0.2% BAK in BCOP, for which no prediction could be made. Overall, all the in vitro tests correlated well with the in vivo rabbit eye irritation test, and furthermore, the combination of in vitro tests as a tiered testing strategy was able to produce results similar to those seen in vivo. These observations suggest that such methods can be used as alternative assays to replace the conventional in vivo test method in the evaluation of the ocular irritancy of ophthalmic medical devices, although further study is necessary. Copyright © 2016. Published by Elsevier Ltd.
Flight-test evaluation of civil helicopter terminal approach operations using differential GPS
NASA Technical Reports Server (NTRS)
Edwards, F. G.; Hegarty, D. M.
1989-01-01
A civil code differential Global Positioning System (DGPS) has been developed and flight-tested by the NASA Ames Research Center. The system was used to evaluate the performance of the DGPS for support of helicopter terminal approach operations. The airborne component of the DGPS was installed in a NASA helicopter. The ground-reference component was installed in a mobile van and equipped with a real-time VHF telemetry data link to transmit correction information to the aircraft system. An extensive series of tests was conducted to evaluate the performance of the system for several different configurations of the airborne navigation filter. This paper will describe the systems, the results of the flight tests, and the results of the posttest analysis.
Evaluating a web-based test results system at an urban STI clinic.
Ling, Sarah B; Richardson, Douglas B; Mettenbrink, Christie J; Westergaard, Benton C; Sapp-Jones, Terri D; Crane, Lori A; Nyquist, Ann-Christine; McFarlane, Mary; Kachur, Rachel; Rietmeijer, Cornelis A
2010-04-01
Notifying patients of gonorrhea and chlamydia test results using online services may improve clinic efficiency and increase receipt of test results. This study evaluated the implementation of an online results system in an urban sexually transmitted infections clinic. Using the clinic's electronic medical records system to assess if and how gonorrhea and chlamydia test results were obtained, 3 time periods were examined between December 2007 and April 2009: period 1, six months before initiation of the online results system; Period 2, six months when patients could opt in for online results by creating their own access codes; and Period 3, four months when access codes were assigned. In addition, a survey was conducted to assess reasons for accepting or declining the online results system. A total of 9056 new patient visits were evaluated. During periods 1, 2, and 3, respectively 67%, 67%, and 70% patients received results either online or by telephone (NS). The proportion of patients calling the clinic for results decreased from 67% in period 1, to 51% in period 2, and 36% in period 3 (P < 0.0001). Survey results indicated that patients accepted online results primarily because of the ability to check results anytime of day. Reasons for not accepting results online included lack of Internet access or a preference to receive results via the telephone. The online results system decreased the number of phone calls to the clinic pertaining to STI test results, but had no effect on the overall proportion of patients receiving results.
75 FR 41531 - Brookwood-Sago Mine Safety Grants
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-16
... stated goals and current reporting period. objectives for improving safety. Conduct and report pre-test and post- test results of trainees. Course evaluations of trainer and training materials. The extent... pre-test and post- and improves safety. educational materials test results of the training materials...
Radiative, actively cooled panel tests results
NASA Technical Reports Server (NTRS)
Shore, C. P.; Nowak, R. J.; Sharpe, E. L.
1978-01-01
The radiative, actively cooled panel designed to withstand a uniform incident heat flux of 136 kW/sq m to a 444 K surface temperature was evaluated. The test program consisted of preliminary static thermal mechanical loading and aerothermal flow tests. Test results are briefly discussed.
Hardware test program for evaluation of baseline range/range rate sensor concept
NASA Technical Reports Server (NTRS)
Pernic, E.
1985-01-01
The test program Phase II effort provides additional design information in terms of range and range rate (R/R) sensor performance when observing and tracking a typical spacecraft target. The target used in the test program was a one-third scale model of the Hubble Space Telescope (HST) available at the MSFC test site where the tests were performed. A modified Bendix millimeter wave radar served as the R/R sensor test bed for evaluation of range and range rate tracking performance, and generation of radar signature characteristics of the spacecraft target. A summary of program test results and conclusions are presented along with detailed description of the Bendix test bed radar with accompaning instrumentation. The MSFC test site and facilities are described. The test procedures used to establish background levels, and the calibration procedures used in the range accuracy tests and RCS (radar cross section) signature measurements, are presented and a condensed version of the daily log kept during the 5 September through 17 September test period is also presented. The test program results are given starting with the RCS signature measurements, then continuing with range measurement accuracy test results and finally the range and range rate tracking accuracy test results.
Meta-Evaluation Applied To Results Of ITS Initiatives
DOT National Transportation Integrated Search
1995-04-01
META-EVALUATION : META-EVALUATION IS A PROCESS TO BE USED FOR THE COMPARISON OF RESULTS ACROSS INTELLIGENT TRANSPORTATION SYSTEMS (ITS). OPERATIONAL TESTS, A COMPONENT OF THE ITS PROGRAM ADMINISTERED BY THE FEDERAL HIGHWAY ADMINISTRATION (FHWA), A...
2014-01-01
Background The use of radio frequency identification (RFID) systems in healthcare is increasing, and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have demonstrated that RFID systems can interfere with medical devices; however, the majority of past studies relied on time-consuming and burdensome test schemes based on ad hoc test methods applied to individual RFID systems. Methods This paper presents the results of using an RFID simulator that allows for faster evaluation of RFID-medical device EMC against a library of RFID test signals at various field strengths. Results The results of these tests demonstrate the feasibility and adequacy of simulator testing and can be used to support its incorporation into applicable consensus standards. Conclusions This work can aid the medical device community in better assessing the risks associated with medical device exposure to RFID. PMID:25086451
NASA Astrophysics Data System (ADS)
Salamunićcar, G.; Lončarić, S.
2008-07-01
Crater Detection Algorithms (CDAs) applications range from estimation of lunar/planetary surface age to autonomous landing on planets and asteroids and advanced statistical analyses. A large amount of work on CDAs has already been published. However, problems arise when evaluation results of some new CDA have to be compared with already published evaluation results. The problem is that different authors use different test-fields, different Ground-Truth (GT) catalogues, and even different methodologies for evaluation of their CDAs. Re-implementation of already published CDAs or its evaluation environment is a time-consuming and unpractical solution to this problem. In addition, implementation details are often insufficiently described in publications. As a result, there is a need in research community to develop a framework for objective evaluation of CDAs. A scientific question is how CDAs should be evaluated so that the results are easily and reliably comparable. In attempt to solve this issue we first analyzed previously published work on CDAs. In this paper, we propose a framework for solution of the problem of objective CDA evaluation. The framework includes: (1) a definition of the measure for differences between craters; (2) test-field topography based on the 1/64° MOLA data; (3) the GT catalogue wherein each of 17,582 craters is aligned with MOLA data and confirmed with catalogues by N.G. Barlow et al. and J.F. Rodionova et al.; (4) selection of methodology for training and testing; and (5) a Free-response Receiver Operating Characteristics (F-ROC) curves as a way to measure CDA performance. The handling of possible improvements of the framework in the future is additionally addressed as a part of discussion of results. Possible extensions with additional test-field subsystems based on visual images, data sets for other planets, evaluation methodologies for CDAs developed for different purposes than cataloguing of craters, are proposed as well. The goal of the proposed framework is to contribute to the research community by establishing guidelines for objective evaluation of CDAs.
NASA Technical Reports Server (NTRS)
Stoliker, Patrick C.; Bosworth, John T.
1996-01-01
The X-31A aircraft gross-acquisition and fine-tracking handling qualities have been evaluated using standard evaluation maneuvers developed by Wright Laboratory, Wright-Patterson Air Force Base. The emphasis of the testing is in the angle-of-attack range between 30 deg and 70 deg. Longitudinal gross-acquisition handling qualities results show borderline Level 1/Level 2 performance. Lateral gross-acquisition testing results in Level 1/Level 2 ratings below 45 deg angle of attack, degrading into Level 3 as angle of attack increases. The fine-tracking performance in both longitudinal and lateral axes also receives Level 1 ratings near 30 deg angle of attack, with the ratings tending towards Level 3 at angles of attack greater than 50 deg. These ratings do not match the expectations from the extensive close-in combat testing where the X-31A aircraft demonstrated fair to good handling qualities maneuvering for high angles of attack. This paper presents the results of the high-angle-of-attack handling qualities flight testing of the X-31A aircraft. Discussion of the preparation for the maneuvers, the pilot ratings, and selected pilot comments are included. Evaluation of the results is made in conjunction with existing Neal-Smith, bandwidth, Smith-Geddes, and military specifications.
NASA Technical Reports Server (NTRS)
Stoliker, Patrick C.; Bosworth, John T.
1997-01-01
The X-31A aircraft gross-acquisition and fine-tracking handling qualities have been evaluated using standard evaluation maneuvers developed by Wright Laboratory, Wright Patterson Air Force Base. The emphasis of the testing is in the angle-of-attack range between 30 deg. and 70 deg. Longitudinal gross-acquisition handling qualities results show borderline Level l/Level 2 performance. Lateral gross-acquisition testing results in Level l/Level 2 ratings below 45 deg. angle of attack, degrading into Level 3 as angle of attack increases. The fine tracking performance in both longitudinal and lateral axes also receives Level 1 ratings near 30 deg. angle of attack, with the ratings tending towards Level 3 at angles of attack greater than 50 deg. These ratings do not match the expectations from the extensive close-in combat testing where the X-31A aircraft demonstrated fair to good handling qualities maneuvering for high angles of attack. This paper presents the results of the high-angle-of-attack handling qualities flight testing of the X-31A aircraft. Discussion of the preparation for the maneuvers, the pilot ratings, and selected pilot comments are included. Evaluation of the results is made in conjunction with existing Neal Smith, bandwidth, Smith-Geddes, and military specifications.
Williams, Janet L; Faucett, W Andrew; Smith-Packard, Bethanny; Wagner, Monisa; Williams, Marc S
2014-08-01
Whole genome sequencing (WGS) is being used for evaluation of individuals with undiagnosed disease of suspected genetic origin. Implementing WGS into clinical practice will place an increased burden upon care teams with regard to pre-test patient education and counseling about results. To quantitate the time needed for appropriate pre-test evaluation of participants in WGS testing, we documented the time spent by our clinical research group on various activities related to program preparation, participant screening, and consent prior to WGS. Participants were children or young adults with autism, intellectual or developmental disability, and/or congenital anomalies, who have remained undiagnosed despite previous evaluation, and their biologic parents. Results showed that significant time was spent in securing allocation of clinical research space to counsel participants and families, and in acquisition and review of participant's medical records. Pre-enrollment chart review identified two individuals with existing diagnoses resulting in savings of $30,000 for the genome sequencing alone, as well as saving hours of personnel time for genome interpretation and communication of WGS results. New WGS programs should plan for costs associated with additional pre-test administrative planning and patient evaluation time that will be required to provide high quality care.
Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields
Rowe, Fiona J.; Rowlands, Alison
2014-01-01
Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5°/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K = 0.775). Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5°/sec for determining boundaries of peripheral isopters and 3°/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size. PMID:24587983
Research on Vehicle-Based Driver Status/Performance Monitoring, Part III
DOT National Transportation Integrated Search
1996-09-01
A driver drowsiness detection/alarm/countermeasures system was specified, tested and evaluated, resulting in the development of revised algorithms for the detection of driver drowsiness. Previous algorithms were examined in a test and evaluation stud...
Research On Vehicle-Based Driver Status/Performance Monitoring, Part I
DOT National Transportation Integrated Search
1996-09-01
A driver drowsiness detection/alarm/countermeasures system was specified, tested and evaluated, resulting in the development of revised algorithms for the detection of driver drowsiness. Previous algorithms were examined in a test and evaluation stud...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-25
... definitive test that documents your disorder (for example, genetic analysis or evidence of biochemical... testing, and We will not accept the fluorescence in situ hybridization (FISH) test--a screening test--and... results even if the person did have a test. Because we do not have definitive test results, we would...
NASA Technical Reports Server (NTRS)
Lee, Sam; Addy, Harold E. Jr.; Broeren, Andy P.; Orchard, David M.
2017-01-01
A test was conducted at NASA Icing Research Tunnel to evaluate altitude scaling methods for thermal ice protection system. Two new scaling methods based on Weber number were compared against a method based on Reynolds number. The results generally agreed with the previous set of tests conducted in NRCC Altitude Icing Wind Tunnel where the three methods of scaling were also tested and compared along with reference (altitude) icing conditions. In those tests, the Weber number-based scaling methods yielded results much closer to those observed at the reference icing conditions than the Reynolds number-based icing conditions. The test in the NASA IRT used a much larger, asymmetric airfoil with an ice protection system that more closely resembled designs used in commercial aircraft. Following the trends observed during the AIWT tests, the Weber number based scaling methods resulted in smaller runback ice than the Reynolds number based scaling, and the ice formed farther upstream. The results show that the new Weber number based scaling methods, particularly the Weber number with water loading scaling, continue to show promise for ice protection system development and evaluation in atmospheric icing tunnels.
Evaluation of Mysidopsis bahia fecundity endpoint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffin, D.; Wahl, E.; Krause, P.R.
1995-12-31
The M. bahia chronic toxicity test is commonly used to test estuarine and marine effluent discharges. The test evaluates three endpoints: survival, growth, and fecundity. The fecundity endpoint is often erratic over time and does not necessarily predict accurately other endpoints of effluent toxicity. Therefore, an analysis of the fecundity endpoint was performed to evaluate its use in compliance testing. The endpoint analysis was conducted in three phases: a literature search, analysis of M. bahia data from 24 separate testing events, and interviews with various policy makers, statisticians, and biologists. The literature search revealed a dozen publications, none of whichmore » evaluated fecundity using the EPA method. The literature suggested that evaluating fecundity was labor-intensive and inadequate for practical compliance testing applications. Analysis of the 24 tests revealed that fecundity was evaluated only half of the time (i.e. when at least 50% of the females in the control were fecund). There was a high coefficient of variation (C.V.) between replicates for fecundity (range = 9.--1209.3,x = 85.2%) as compared to survival (range = 0.0--24.0,x = 13.7 %) and growth (range = 7.5--43.9,x = 19.1%). The fecundity results were erratic and did not always follow a dose-response curve, due in part to the small sample size per replicate. Interviews showed that the fecundity endpoint was being evaluated differently by different laboratories. Some were using fecundity for compliance while others were not. Most people interviewed recognized there were inconsistencies with the endpoint. The conclusions drawn from the evaluation were that (1) fecundity does not lend itself for use as a compliance endpoint, (2) the fecundity evaluation process is time consuming and labor intensive, and (3) interpretation of the results is not consistent from laboratory to laboratory and from region to region.« less
Mechanical properties of Municipal Solid Waste by SDMT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castelli, Francesco, E-mail: francesco.castelli@unikore.it; Maugeri, Michele
2014-02-15
Highlights: • The adoption of the SDMT for the measurements of MSW properties is proposed. • A comparison between SDMT results and laboratory tests was carried out. • A good reliability has been found in deriving waste properties by SDMT. • Results seems to be promising for the friction angle and Young’s modulus evaluation. - Abstract: In the paper the results of a geotechnical investigation carried on Municipal Solid Waste (MSW) materials retrieved from the “Cozzo Vuturo” landfill in the Enna area (Sicily, Italy) are reported and analyzed. Mechanical properties were determined both by in situ and laboratory large-scale onemore » dimensional compression tests. While among in situ tests, Dilatomer Marchetti Tests (DMT) is used widely in measuring soil properties, the adoption of the DMT for the measurements of MSW properties has not often been documented in literature. To validate its applicability for the estimation of MSW properties, a comparison between the seismic dilatometer (SDMT) results and the waste properties evaluated by laboratory tests was carried out. Parameters for “fresh” and “degraded waste” have been evaluated. These preliminary results seems to be promising as concerns the assessment of the friction angle of waste and the evaluation of the S-wave in terms of shear wave velocity. Further studies are certainly required to obtain more representative values of the elastic parameters according to the SDMT measurements.« less
Development and Test Evaluations for Ni-DOBDC Metal Organic Framework (MOF) Engineered Forms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Troy G. Garn; Mitchell Greenhalgh
2013-07-01
A joint effort to prepare engineered forms of a Ni-DOBDC metal organic framework (MOF) was completed with contributions from PNNL, SNL and the INL. Two independent methods were used at INL and SNL to prepare engineered form (EF) sorbents from Ni-DOBDC MOF powder developed and prepared at PNNL. Xe and Kr capacity test evaluations were performed at ambient temperature with the cryostat experimental setup at INL. The initial INL EF MOF test results indicated a Xe capacity of 1.6 mmol/kg sorbent and no Kr capacity. A large loss of surface area also occurred during minimal testing rendering the INL EFmore » MOF unusable. Four capacity tests were completed using the SNL EF MOF at ambient temperature and resulted in Xe capacities of 1.4, 4.2, 5.0 and 3.8 mmol/kg sorbent with no Kr capacity observed in any ambient temperature tests. Two additional capacity tests were performed at 240 K to further evaluate SNL EF MOF performance. Xe capacities of 50.7 and 49.3 mmol/kg of sorbent and Kr capacities of 0.77 and 0.69 mmol/kg of sorbent were obtained, respectively. Following the adsorption evaluations, the SNL EF MOF material had lost about 40 % of the initial mass and 40 % of the initial surface area. In general, the Xe capacity results at ambient temperature for the INL and SNL EF Ni-DOBDC MOF’s were lower than 9.8 mmol Xe/kg sorbent test results reported by INL in FY-12 using PNNL’s inital EF supplied material.« less
GICHD mine dog testing project - soil sample results #4.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.
2003-08-01
A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performancemore » and seasonal weather conditions. This report documents the analytical chemical methods and results from the fourth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in April 2003 and Sarajevo, Bosnia collected in May 2003.« less
NASA Astrophysics Data System (ADS)
Nepomuceno, Miguel C. S.; Lopes, Sérgio M. R.
2017-10-01
Non-destructive tests (NDT) have been used in the last decades for the assessment of in-situ quality and integrity of concrete elements. An important step in the application of NDT methods concerns to the interpretation and validation of the test results. In general, interpretation of NDT results should involve three distinct phases leading to the development of conclusions: processing of collected data, analysis of within-test variability and quantitative evaluation of property under investigation. The analysis of within-test variability can provide valuable information, since this can be compared with that of within-test variability associated with the NDT method in use, either to provide a measure of the quality control or to detect the presence of abnormal circumstances during the in-situ application. This paper reports the analysis of the experimental results of within-test variability of NDT obtained for normal vibrated concrete and self-compacting concrete. The NDT reported includes the surface hardness test, ultrasonic pulse velocity test, penetration resistance test, pull-off test, pull-out test and maturity test. The obtained results are discussed and conclusions are presented.
Schleifer, Sebastian G; Willemse, Ton
2003-06-01
To evaluate skin test reactivity to environmental allergens in healthy cats and in cats with atopic dermatitis (AD). 10 healthy cats and 10 cats with AD. 10 allergens in serial dilutions were injected ID on the lateral aspect of the thorax of sedated cats. Histamine (0.01% solution) and buffer solutions were used as positive and negative controls, respectively. Immediately after the last injection, 10% fluorescein solution was administered IV. Skin test results were evaluated with ultraviolet light after 15 to 30 minutes and at 4 and 6 hours by 2 independent observers. In the control group, skin tests were repeated after 6 weeks. Skin test reactivity and the nature of the immunoglobulin involved were investigated by use of the Prausnitz-Küstner test with untreated and heat-treated cat sera. Intertest and interobserver agreement were high when measurement of the diameter of the fluorescent wheal was used to evaluate skin test responses, compared with assessment of its intensity. In both groups of cats, immediate skin test reactivity was observed as an IgE-mediated reaction, as an IgG-mediated reaction, and as a result of nonspecific mast cell degranulation. There was no correlation between allergen concentration and the type of reaction observed. Skin test reactivity in cats should be evaluated after IV administration of 10% fluorescein solution by means of a Prausnitz-Küstner test to differentiate among IgE-mediated, IgG-mediated, and nonspecific reactions.
50 CFR 679.28 - Equipment and operational requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... sea. In order to be approved by NMFS a scale used to weigh catch at sea must meet the type evaluation... information regarding the manufacturer, and sets forth the results of required type evaluations and testing. Type evaluation and testing must be conducted by a laboratory accredited by the government of the...
High Temperature Evaluation of Tantalum Capacitors - Test 1
Cieslewski, Grzegorz
2014-09-28
Tantalum capacitors can provide much higher capacitance at high-temperatures than the ceramic capacitors. This study evaluates selected tantalum capacitors at high temperatures to determine their suitability for you in geothermal field. This data set contains results of the first test where three different types of capacitors were evaluated at 260C.
Evaluation of the Albuquerque Indian School Motivational Environment Program.
ERIC Educational Resources Information Center
Hiat, Albert B.; And Others
In order to evaluate the impact of a token economy behavior modification program implemented from 1970-71 in the Albuquerque Indian School (AIS), a secondary institution, a five-member evaluation team assessed standardized test results, behavioral data, and student and staff attitudes. A battery of tests (Tennessee Self-Concept Scale, SRA…
The development of Metacognition test in genetics laboratory for undergraduate students
NASA Astrophysics Data System (ADS)
A-nongwech, Nattapong; Pruekpramool, Chaninan
2018-01-01
The purpose of this research was to develop a Metacognition test in a Genetics Laboratory for undergraduate students. The participants were 30 undergraduate students of a Rajabhat university in Rattanakosin group in the second semester of the 2016 academic year using purposive sampling. The research instrument consisted of 1) Metacognition test and 2) a Metacognition test evaluation form for experts focused on three main points which were an accurate evaluation form of content, a consistency between Metacognition experiences and questions and the appropriateness of the test. The quality of the test was analyzed by using the Index of Consistency (IOC), discrimination and reliability. The results of developing Metacognition test were summarized as 1) The result of developing Metacognition test in a Genetics Laboratory for undergraduate students found that the Metacognition test contained 56 items of open - ended questions. The test composed of 1) four scientific situations, 2) fourteen items of open - ended questions in each scientific situation for evaluating components of Metacognition. The components of Metacognition consisted of Metacognitive knowledge, which were divided into person knowledge, task knowledge and strategy knowledge and Metacognitive experience, which were divided into planning, monitoring and evaluating, and 3) fourteen items of scoring criteria divided into four scales. 2) The results of the item analysis of Metacognition in Genetics Laboratory for undergraduate students found that Index of Consistency between Metacognitive experiences and questions were in the range between 0.75 - 1.00. An accuracy of content equaled 1.00. The appropriateness of the test equaled 1.00 in all situations and items. The discrimination of the test was in the range between 0.00 - 0.73. Furthermore, the reliability of the test equaled 0.97.
Preliminary test results for Li-SOCl2 high-rate D cells
NASA Technical Reports Server (NTRS)
Bragg, Bobby J.; Johnson, Paul
1992-01-01
The performance and abuse characteristics of 55 D-size lithium-thionyl chloride (Li-SOCl2) cells are evaluated at relatively high rates. Results from the following tests are presented: shock test, vibration test, capacity performance, uninsulated short circuit, high temperature exposure, and overdischarge.
Preliminary test results for Li-SOCl2 high-rate D cells
NASA Astrophysics Data System (ADS)
Bragg, Bobby J.; Johnson, Paul
1992-02-01
The performance and abuse characteristics of 55 D-size lithium-thionyl chloride (Li-SOCl2) cells are evaluated at relatively high rates. Results from the following tests are presented: shock test, vibration test, capacity performance, uninsulated short circuit, high temperature exposure, and overdischarge.
Applicability of Monte-Carlo Simulation to Equipment Design of Radioactive Noble Gas Monitor
NASA Astrophysics Data System (ADS)
Sakai, Hirotaka; Hattori, Kanako; Umemura, Norihiro
In the nuclear facilities, radioactive noble gas is continuously monitored by using the radioactive noble gas monitor with beta-sensitive plastic scintillation radiation detector. The detection efficiency of the monitor is generally calibrated by using a calibration loop and standard radioactive noble gases such as 85Kr. In this study, the applicability of PHITS to the equipment design of the radioactive noble gas monitor was evaluated by comparing the calculated results to the test results obtained by actual calibration loop tests to simplify the radiation monitor design evaluation. It was confirmed that the calculated results were well matched to the test results of the monitor after the modeling. In addition, the key parameters for equipment design, such as thickness of detector window or depth of the sampler, were also specified and evaluated.
Umay, Ebru Karaca; Unlu, Ece; Saylam, Guleser Kılıc; Cakci, Aytul; Korkmaz, Hakan
2013-09-01
We aimed in this study to evaluate dysphagia in early stroke patients using a bedside screening test and flexible fiberoptic endoscopic evaluation of swallowing (FFEES) and electrophysiological evaluation (EE) methods and to compare the effectiveness of these methods. Twenty-four patients who were hospitalized in our clinic within the first 3 months after stroke were included in this study. Patients were evaluated using a bedside screening test [including bedside dysphagia score (BDS), neurological examination dysphagia score (NEDS), and total dysphagia score (TDS)] and FFEES and EE methods. Patients were divided into normal-swallowing and dysphagia groups according to the results of the evaluation methods. Patients with dysphagia as determined by any of these methods were compared to the patients with normal swallowing based on the results of the other two methods. Based on the results of our study, a high BDS was positively correlated with dysphagia identified by FFEES and EE methods. Moreover, the FFEES and EE methods were positively correlated. There was no significant correlation between NEDS and TDS levels and either EE or FFEES method. Bedside screening tests should be used mainly as an initial screening test; then FFEES and EE methods should be combined in patients who show risks. This diagnostic algorithm may provide a practical and fast solution for selected stroke patients.
Flight tests for the assessment of task performance and control activity
NASA Technical Reports Server (NTRS)
Pausder, H. J.; Hummes, D.
1982-01-01
The tests were performed with the helicopters BO 105 and UH-1D. Closely connected with tactical demands the six test pilots' task was to minimize the time and the altitude over the obstacles. The data reduction yields statistical evaluation parameters describing the control activity of the pilots and the achieved task performance. The results are shown in form of evaluation diagrams. Additionally dolphin tests with varied control strategy were performed to get more insight into the influence of control techniques. From these test results recommendations can be derived to emphasize the direct force control and to reduce the collective to pitch crosscoupling for the dolphin.
Test results on reuse of reclaimed shower water - A summary
NASA Technical Reports Server (NTRS)
Verostko, Charles E.; Garcia, Rafael; Sauer, Richard; Reysa, Richard P.; Linton, Arthur T.
1989-01-01
Results are presented from tests to evaluate a microgravity whole body shower and waste water recovery system design for possible use on the Space Station. Several water recovery methods were tested, including phase change distillation, a thermoelectric hollow fiber membrane evaporation subsystem, and a reverse osmosis dynamic membrane system. Consideration is given to the test hardware, the types of soaps evaluated, the human response to showering with reclaimed water, chemical treatment for microbial control, the procedures for providing hygienic water, and the quality of water produced by the systems. All three of the waste water recovery systems tested successfully produced reclaimed water for reuse.
Individual class evaluation and effective teaching characteristics in integrated curricula.
Hwang, Jung Eun; Kim, Na Jin; Song, Meiying; Cui, Yinji; Kim, Eun Ju; Park, In Ae; Lee, Hye In; Gong, Hye Jin; Kim, Su Young
2017-12-12
In an integrated curriculum, multiple instructors take part in a course in the form of team teaching. Accordingly, medical schools strive to manage each course run by numerous instructors. As part of the curriculum management, course evaluation is conducted, but a single, retrospective course evaluation does not comprehensively capture student perception of classes by different instructors. This study aimed to demonstrate the need for individual class evaluation, and further to identify teaching characteristics that instructors need to keep in mind when preparing classes. From 2014 to 2015, students at one medical school left comments on evaluation forms after each class. Courses were also assessed after each course. Their comments were categorized by connotation (positive or negative) and by subject. Within each subject category, test scores were compared between positively and negatively mentioned classes. The Mann-Whitney U test was performed to test group differences in scores. The same method was applied to the course evaluation data. Test results for course evaluation showed group difference only in the practice/participation category. However, test results for individual class evaluation showed group differences in six categories: difficulty, main points, attitude, media/contents, interest, and materials. That is, the test scores of classes positively mentioned in six domains were significantly higher than those of negatively mentioned classes. It was proved that individual class evaluation is needed to manage multi-instructor courses in integrated curricula of medical schools. Based on the students' extensive feedback, we identified teaching characteristics statistically related to academic achievement. School authorities can utilize these findings to encourage instructors to develop effective teaching characteristics in class preparation.
International Space Station alpha remote manipulator system workstation controls test report
NASA Astrophysics Data System (ADS)
Ehrenstrom, William A.; Swaney, Colin; Forrester, Patrick
1994-05-01
Previous development testing for the space station remote manipulator system workstation controls determined the need for hardware controls for the emergency stop, brakes on/off, and some camera functions. This report documents the results of an evaluation to further determine control implementation requirements, requested by the Canadian Space Agency (CSA), to close outstanding review item discrepancies. This test was conducted at the Johnson Space Center's Space Station Mockup and Trainer Facility in Houston, Texas, with nine NASA astronauts and one CSA astronaut as operators. This test evaluated camera iris and focus, back-up drive, latching end effector release, and autosequence controls using several types of hardware and software implementations. Recommendations resulting from the testing included providing guarded hardware buttons to prevent accidental actuation, providing autosequence controls and back-up drive controls on a dedicated hardware control panel, and that 'latch on/latch off', or on-screen software, controls not be considered. Generally, the operators preferred hardware controls although other control implementations were acceptable. The results of this evaluation will be used along with further testing to define specific requirements for the workstation design.
International Space Station alpha remote manipulator system workstation controls test report
NASA Technical Reports Server (NTRS)
Ehrenstrom, William A.; Swaney, Colin; Forrester, Patrick
1994-01-01
Previous development testing for the space station remote manipulator system workstation controls determined the need for hardware controls for the emergency stop, brakes on/off, and some camera functions. This report documents the results of an evaluation to further determine control implementation requirements, requested by the Canadian Space Agency (CSA), to close outstanding review item discrepancies. This test was conducted at the Johnson Space Center's Space Station Mockup and Trainer Facility in Houston, Texas, with nine NASA astronauts and one CSA astronaut as operators. This test evaluated camera iris and focus, back-up drive, latching end effector release, and autosequence controls using several types of hardware and software implementations. Recommendations resulting from the testing included providing guarded hardware buttons to prevent accidental actuation, providing autosequence controls and back-up drive controls on a dedicated hardware control panel, and that 'latch on/latch off', or on-screen software, controls not be considered. Generally, the operators preferred hardware controls although other control implementations were acceptable. The results of this evaluation will be used along with further testing to define specific requirements for the workstation design.
Shimelis, Techalew; Tadesse, Endale
2015-01-01
Objective To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. Design A hospital-based cross-sectional study. Setting This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Participants Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. Outcome measures HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). Results The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. Conclusions The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. PMID:25908677
Kosack, Cara S; Page, Anne-Laure; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Shanks, Leslie; Fransen, Katrien
2017-01-01
Abstract Introduction: Although individual HIV rapid diagnostic tests (RDTs) show good performance in evaluations conducted by WHO, reports from several African countries highlight potentially significant performance issues. Despite widespread use of RDTs for HIV diagnosis in resource-constrained settings, there has been no systematic, head-to-head evaluation of their accuracy with specimens from diverse settings across sub-Saharan Africa. We conducted a standardized, centralized evaluation of eight HIV RDTs and two simple confirmatory assays at a WHO collaborating centre for evaluation of HIV diagnostics using specimens from six sites in five sub-Saharan African countries. Methods: Specimens were transported to the Institute of Tropical Medicine (ITM), Antwerp, Belgium for testing. The tests were evaluated by comparing their results to a state-of-the-art reference algorithm to estimate sensitivity, specificity and predictive values. Results: 2785 samples collected from August 2011 to January 2015 were tested at ITM. All RDTs showed very high sensitivity, from 98.8% for First Response HIV Card Test 1–2.0 to 100% for Determine HIV 1/2, Genie Fast, SD Bioline HIV 1/2 3.0 and INSTI HIV-1/HIV-2 Antibody Test kit. Specificity ranged from 90.4% for First Response to 99.7% for HIV 1/2 STAT-PAK with wide variation based on the geographical origin of specimens. Multivariate analysis showed several factors were associated with false-positive results, including gender, provider-initiated testing and the geographical origin of specimens. For simple confirmatory assays, the total sensitivity and specificity was 100% and 98.8% for ImmunoComb II HIV 12 CombFirm (ImmunoComb) and 99.7% and 98.4% for Geenius HIV 1/2 with indeterminate rates of 8.9% and 9.4%. Conclusions: In this first systematic head-to-head evaluation of the most widely used RDTs, individual RDTs performed more poorly than in the WHO evaluations: only one test met the recommended thresholds for RDTs of ≥99% sensitivity and ≥98% specificity. By performing all tests in a centralized setting, we show that these differences in performance cannot be attributed to study procedure, end-user variation, storage conditions, or other methodological factors. These results highlight the existence of geographical and population differences in individual HIV RDT performance and underscore the challenges of designing locally validated algorithms that meet the latest WHO-recommended thresholds. PMID:28364560
Evaluation and Management of Patch Test-Negative Patients With Generalized Dermatitis.
Spiker, Alison; Mowad, Christen M
Patients with generalized dermatitis are common in dermatology practices. Allergic contact dermatitis is often suspected, and patients frequently undergo patch testing. When the patch testing result is negative, further evaluation and management of these patients are challenging. The purpose of this study was to survey members of the American Contact Dermatitis Society regarding the evaluation and management of patch test-negative patients with generalized dermatitis. Generalized dermatitis was the most common term identified for patch test-negative patients with diffuse dermatitis. After having negative expanded patch testing results, most physicians proceeded with additional testing including skin biopsy, complete blood cell count with differential, and liver and renal function tests. The most commonly used systemic treatment is prednisone, followed by methotrexate. Narrow-band ultraviolet B (UVB) is the most commonly used light source. Antihistamines are frequently prescribed. Food allergy is not felt to be causative. This cohort of patients experiences significant impairment in quality of life, stress on personal relationships, and time off work. The management of patch test-negative patients with generalized dermatitis is challenging. This study provides insight into management of these complex patients. It also demonstrates practice gaps in the management of these patients, indicating a need for further studies to direct the evaluation and management of this patient population.
Evaluation of a metering, mixing, and dispensing system for mixing polysulfide adhesive
NASA Technical Reports Server (NTRS)
Evans, Kurt B.
1989-01-01
Tests were performed to evaluate whether a metered mixing system can mix PR-1221 polysulfide adhesive as well as or better than batch-mixed adhesive; also, to evaluate the quality of meter-mixed PR-1860 and PS-875 polysulfide adhesives. These adhesives are candidate replacements for PR-1221 which will not be manufactured in the future. The following material properties were evaluated: peel strength, specific gravity and adhesive components of mixed adhesives, Shore A hardness, tensile adhesion strength, and flow rate. Finally, a visual test called the butterfly test was performed to observe for bubbles and unmixed adhesive. The results of these tests are reported and discussed.
A simple test for thermomechanical evaluation of ceramic fibers
NASA Technical Reports Server (NTRS)
Morscher, Gregory N.; Dicarlo, James A.
1991-01-01
A simple bend stress relaxation (BSR) test was developed to measure the creep related properties of ceramic fibers and whiskers. The test was applied to a variety of commercial and developmental Si based fibers to demonstrate capabilities and to evaluate the relative creep resistance of the fibers at 1200 to 1400 C. The implications of these results and the advantages of the BSR test over typical tensile creep tests are discussed.
Long life reliability thermal control systems study
NASA Technical Reports Server (NTRS)
Scollon, T. R., Jr.; Killen, R. E.
1972-01-01
The results of a program undertaken to conceptually design and evaluate a passive, high reliability, long life thermal control system for space station application are presented. The program consisted of four steps: (1) investigate and select potential thermal system elements; (2) conceive, evaluate and select a thermal control system using these elements; (3) conduct a verification test of a prototype segment of the selected system; and (4) evaluate the utilization of waste heat from the power supply. The result of this project is a conceptual thermal control system design which employs heat pipes as primary components, both for heat transport and temperature control. The system, its evaluation, and the test results are described.
Test and evaluation procedures for Sandia's Teraflops Operating System (TOS) on Janus.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnette, Daniel Wayne
This report describes the test and evaluation methods by which the Teraflops Operating System, or TOS, that resides on Sandia's massively-parallel computer Janus is verified for production release. Also discussed are methods used to build TOS before testing and evaluating, miscellaneous utility scripts, a sample test plan, and a proposed post-test method for quickly examining the large number of test results. The purpose of the report is threefold: (1) to provide a guide to T&E procedures, (2) to aid and guide others who will run T&E procedures on the new ASCI Red Storm machine, and (3) to document some ofmore » the history of evaluation and testing of TOS. This report is not intended to serve as an exhaustive manual for testers to conduct T&E procedures.« less
3 CFR - Expanding America's Leadership in Wireless Innovation
Code of Federal Regulations, 2014 CFR
2014-01-01
... results from the Networking and Information Technology Research and Development Program, shall publish an... in research, development, testing, and evaluation of technologies to enhance spectrum sharing and... templates governing the following: research, development, testing, and evaluation of spectrum sharing...
An evaluation of bituminized fiber pipe culverts.
DOT National Transportation Integrated Search
1970-01-01
This report describes the results to date in a limited study, including laboratory tests and field evaluations, of the suitability of bituminized fiber pipe for use as highway culverts. Crushing strength data obtained from three-edge bearing tests in...
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1974-01-01
An evaluation test of the 20.0 ampere-hour cells was conducted to insure that all cells put into the life cycle program are of high quality. This is accomplished by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test. The results obtained in the test are given, as well as the recommendations based on these findings.
Evaluation of dispersion strengthened nickel-base alloy heat shields for space shuttle application
NASA Technical Reports Server (NTRS)
Johnson, R., Jr.; Killpatrick, D. H.
1975-01-01
The design, fabrication, and testing of a full-size, full-scale TD Ni-20Cr heat shield test array in simulated mission environments is described along with the design and fabrication of two additional full-size, full-scale test arrays to be tested in flowing gas test facilities at the NASA Langley Research Center. Cost and reusability evaluations of TD Ni-20Cr heat shield systems are presented, and weight estimates of a TD Ni-20Cr heat shield system for use on a shuttle orbiter vehicle are made. Safe-line expectancy of a TD Ni-20Cr heat shield system is assessed. Non-destructive test techniques are evaluated to determine their effectiveness in quality assurance checks of TD Ni-20Cr components such as heat shields, heat shield supports, close-out panels, formed cover strips, and edge seals. Results of tests on a braze reinforced full-scale, subsize panel are included. Results show only minor structural degradation in the main TD Ni-20Cr heat shields of the test array during simulated mission test cycles.
NASA Technical Reports Server (NTRS)
Yen, Judy C. H.; Tomsik, Thomas M.
2004-01-01
This paper describes the results of a series of catalyst screening tests conducted with Jet-A fuel under auto-thermal reforming (ATR) process conditions at the research laboratories of SOFCo-EFS Holdings LLC under Glenn Research Center Contract. The primary objective is to identify best available catalysts for future testing at the NASA GRC 10-kW(sub e) reformer test facility. The new GRC reformer-injector test rig construction is due to complete by March 2004. Six commercially available monolithic catalyst materials were initially selected by the NASA/SOFCo team for evaluation and bench scale screening in an existing 0.05 kW(sub e) microreactor test apparatus. The catalyst screening tests performed lasted 70 to 100 hours in duration in order to allow comparison between the different samples over a defined range of ATR process conditions. Aging tests were subsequently performed with the top two ranked catalysts as a more representative evaluation of performance in a commercial aerospace application. The two catalyst aging tests conducted lasting for approximately 600 hours and 1000 hours, respectively.
Analytical Round Robin for Elastic-Plastic Analysis of Surface Cracked Plates, Phase II Results
NASA Technical Reports Server (NTRS)
Allen, P. A.; Wells, D. N.
2017-01-01
The second phase of an analytical round robin for the elastic-plastic analysis of surface cracks in flat plates was conducted under the auspices of ASTM Interlaboratory Study 732. The interlaboratory study (ILS) had 10 participants with a broad range of expertise and experience, and experimental results from a surface crack tension test in 4142 steel plate loaded well into the elastic-plastic regime provided the basis for the study. The participants were asked to evaluate a surface crack tension test according to the version of the surface crack initiation toughness testing standard published at the time of the ILS, E2899-13. Data were provided to each participant that represent the fundamental information that would be provided by a mechanical test laboratory prior to evaluating the test result. Overall, the participant’s test analysis results were in good agreement and constructive feedback was received that has resulted in an improved published version of the standard E2899-15.
Wu, Cheng-Ching; Lin, Hung-Yu; Wang, Chao-Ping; Lu, Li-Fen; Yu, Teng-Hung; Hung, Wei-Chin; Houng, Jer-Yiing; Chung, Fu-Mei; Lee, Yau-Jiunn; Hu, Jin-Jia
2015-11-03
Prostate cancer remains the most common cancer in men. Qualitative or semi-quantitative immunochromatographic measurements of prostate specific antigen (PSA) have been shown to be simple, noninvasive and feasible. The aim of this study was to evaluate an optimized gold immunochromatographic strip device for the detection of PSA, in which the results can be analysed using a Chromogenic Rapid Test Reader to quantitatively assess the test results. This reader measures the reflectance of the signal line via a charge-coupled device camera. For quantitative analysis, PSA concentration was computed via a calibration equation. Capillary blood samples from 305 men were evaluated, and two independent observers interpreted the test results after 12 min. Blood samples were also collected and tested with a conventional quantitative assay. Sensitivity, specificity, positive and negative predictive values, and accuracy of the PSA rapid quantitative test system were 100, 96.6, 89.5, 100, and 97.4 %, respectively. Reproducibility of the test was 99.2, and interobserver variation was 8 % with a false positive rate of 3.4 %. The correlation coefficient between the ordinary quantitative assay and the rapid quantitative test was 0.960. The PSA rapid quantitative test system provided results quickly and was easy to use, so that tests using this system can be easily performed at outpatient clinics or elsewhere. This system may also be useful for initial cancer screening and for point-of-care testing, because results can be obtained within 12 min and at a cost lower than that of conventional quantitative assays.
ERIC Educational Resources Information Center
Chesterfield, Ray; And Others
The purpose of this part of the multimethod Head Start bilingual/bicultural curriculum evaluation (Juarez and Associates, 1979), is to present the results of a pilot test of a battery of instruments to be used in assessing the effectiveness of four early childhood bilingual/bicultural curriculum models. The instruments pilot tested were the…
The Use of Test Results from ASA Workshops to Evaluate Workshop Effectiveness
ERIC Educational Resources Information Center
Donegan, Judith H.; And Others
1976-01-01
Results of test given to participants in six American Society of Anesthesiologists workshops were analyzed to determine whether attendance increased scores on sequential tests (before, immediately after, and three months later). Both workshop and control groups of anesthesiologists increased their scores with each successive test. (Editor/JT)
Evaluation of the concept of pressure proof testing fuselage structures
NASA Technical Reports Server (NTRS)
Harris, Charles E.; Orringer, Oscar
1991-01-01
The FAA and NASA have recently completed independent technical evaluations of the concept of pressure proof testing the fuselage of commercial transport airplanes. The results of these evaluations are summarized. The objectives of the evaluations were to establish the potential benefit of the pressure proof test, to quantify the most desirable proof test pressure, and to quantify the required proof test interval. The focus of the evaluations was on multiple-site cracks extending from adjacent rivet holes of a typical fuselage longitudinal lap splice joint. The FAA and NASA do not support pressure proof testing the fuselage of aging commercial transport aircraft. The argument against proof testing is as follows: (1) a single proof test does not insure an indefinite life; therefore, the proof test must be repeated at regular intervals; (2) for a proof factor of 1.33, the required proof test interval must be below 300 flights to account for uncertainties in the evaluation; (3) conducting the proof test at a proof factor of 1.5 would considerably exceed the fuselage design limit load; therefore, it is not consistent with accepted safe practices; and (4) better safety can be assured by implementing enhanced nondestructive inspection requirements, and adequate reliability can be achieved by an inspection interval several times longer than the proof test interval.
Evaluation of three percent Aqueous Film Forming Foam (AFFF) concentrates as fire fighting agents
NASA Astrophysics Data System (ADS)
Jablonski, E. J.
1981-04-01
A large-scale fire test program involving 20,000-square foot JP-4 fuel fires was conducted to evaluate the fire suppression effectiveness and compatibility of 3 percent Aqueous Film Forming Foam (AFFF) agents in Air Force fire fighting vehicles. Three commercially available 3 percent AFFF concentrates were tested in accordance with military specification MIL-F-24385B. Test results are summarized in Appendix A. As a result of these tests, an updated Revision C to this MIL SPEC has been accomplished with new requirements for both 3 percent and 6 percent AFFF extinguishing agents.
The evaluation of a number of prototypes for the free-tip rotor constant-moment controller
NASA Technical Reports Server (NTRS)
Young, L. A.
1986-01-01
The development of several prototypes of a constant moment controller, a critical component of the free-tip rotor (FTR) concept, is described. Also presented are the experimental results of a whirl test designed to select a final controller configuration to be included in a future wind-tunnel test of this innovative rotor system. A brief explanation of the FTR concept and its history are included. The paper documents the controller design constraints, each prototype's operating principle, the evaluation test, and the individual prototype test results. A recommended design is identified, along with the selection rationale.
Electronic evaluation for freshmen nursing students: Advantages and disadvantages.
González, Fidelina; Ramírez, Julia
2006-01-01
An electronic evaluation was applied to freshmen nursing students who are taking Biology and Nursing Introduction. Questions and alternatives were randomly ordered. Evaluation took place simultaneously for all the students. Students preferred multiple choice questions with no more than two lines of headings and requested about three minutes for test timing. Test scores from electronic evaluation were higher than the ones obtained with written evaluation. This result implies that information technology can be used for evaluating large group of students.
Evaluation and Testing of Rail Transit Undercar Fire Detection and Suppression Systems
DOT National Transportation Integrated Search
1989-08-01
This document presents the results of a comprehensive review and evaluation of transit undercar fire detection and suppression methods. The evaluation of fire detection method resulted in a recommendation that continuous wire type linear thermal dete...
Kunkle, Gerald A.
2016-01-07
The Sutron 8310-N-S (8310) data collection platform (DCP) manufactured by Sutron Corporation was evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) for conformance to the manufacturer’s specifications for recording and transmitting data. The 8310-N-S is a National Electrical Manufacturers Association (NEMA)-enclosed DCP with a built-in Geostationary Operational Environmental Satellite transmitter that operates over a temperature range of −40 to 60 degrees Celsius (°C). The evaluation procedures followed and the results obtained are described in this report for bench, temperature chamber, and outdoor deployment testing. The three units tested met the manufacturer’s stated specifications for the tested conditions, but two of the units had transmission errors either during temperature chamber or deployment testing. During outdoor deployment testing, 6.72 percent of transmissions by serial number 1206109 contained errors, resulting in missing data. Transmission errors were also observed during temperature chamber testing with serial number 1208283, at an error rate of 3.22 percent. Overall, the 8310 has good logging capabilities, but the transmission errors are a concern for users who require reliable telemetered data.
Flight test of the X-29A at high angle of attack: Flight dynamics and controls
NASA Technical Reports Server (NTRS)
Bauer, Jeffrey E.; Clarke, Robert; Burken, John J.
1995-01-01
The NASA Dryden Flight Research Center has flight tested two X-29A aircraft at low and high angles of attack. The high-angle-of-attack tests evaluate the feasibility of integrated X-29A technologies. More specific objectives focus on evaluating the high-angle-of-attack flying qualities, defining multiaxis controllability limits, and determining the maximum pitch-pointing capability. A pilot-selectable gain system allows examination of tradeoffs in airplane stability and maneuverability. Basic fighter maneuvers provide qualitative evaluation. Bank angle captures permit qualitative data analysis. This paper discusses the design goals and approach for high-angle-of-attack control laws and provides results from the envelope expansion and handling qualities testing at intermediate angles of attack. Comparisons of the flight test results to the predictions are made where appropriate. The pitch rate command structure of the longitudinal control system is shown to be a valid design for high-angle-of-attack control laws. Flight test results show that wing rock amplitude was overpredicted and aileron and rudder effectiveness were underpredicted. Flight tests show the X-29A airplane to be a good aircraft up to 40 deg angle of attack.
NASA Technical Reports Server (NTRS)
Wood, Jessica J.; Foster, Lee W.
2013-01-01
A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.
Evaluation of DuPont Qualicon Bax System PCR assay for yeast and mold.
Wallace, F Morgan; Burns, Frank; Fleck, Lois; Andaloro, Bridget; Farnum, Andrew; Tice, George; Ruebl, Joanne
2010-01-01
Evaluations were conducted to test the performance of the BAX System PCR assay which was certified as Performance Tested Method 010902 for screening yeast and mold in yogurt, corn starch, and milk-based powdered infant formula. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent to the U.S. Food and Drug Administration's Bacteriological Analytical Manual culture method, but with a significantly shorter time to obtain results. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affected the performance of the assay.
Expert Systems In Medical Studies - A New Twist
NASA Astrophysics Data System (ADS)
Slagle, James R.; Long, John M.; Wick, Michael R.; Matts, John P.; Leon, Arthur S.
1986-03-01
The use of experts to evaluate large amounts of trial data results in increasingly expensive and time consuming research. We are investigating the role expert systems can play in reducing the time and expense of research projects. Current methods in large clinical studies for evaluating data are often crude and superficial. We have developed, for a large clinical trial, an expert system for analysis of treadmill exercise ECG test results. In the cases we are studying, a patient is given a treadmill exercise ECG test once a year for five years. Pairs of these exercise tests are then evaluated by cardiologists to determine the condition of the patient's heart. The results of our system show great promise for the use of expert systems in reducing the time and expense of large clinical trials.
Results and conclusions: perception sensor study for high speed autonomous operations
NASA Astrophysics Data System (ADS)
Schneider, Anne; LaCelle, Zachary; Lacaze, Alberto; Murphy, Karl; Close, Ryan
2016-05-01
Previous research has presented work on sensor requirements, specifications, and testing, to evaluate the feasibility of increasing autonomous vehicle system speeds. Discussions included the theoretical background for determining sensor requirements, and the basic test setup and evaluation criteria for comparing existing and prototype sensor designs. This paper will present and discuss the continuation of this work. In particular, this paper will focus on analyzing the problem via a real-world comparison of various sensor technology testing results, as opposed to previous work that utilized more of a theoretical approach. LADAR/LIDAR, radar, visual, and infrared sensors are considered in this research. Results are evaluated against the theoretical, desired perception specifications. Conclusions for utilizing a suite of perception sensors, to achieve the goal of doubling ground vehicle speeds, is also discussed.
Jonczyk, E; Gilron, G; Zajdlik, B
2001-04-01
Most industrial effluents discharged into the marine coastal environment are freshwater in nature and therefore require manipulation prior to testing with marine organisms. The sea urchin fertilization test is a common marine bioassay used for routine environmental monitoring, investigative evaluations, and/or regulatory testing of effluents and sediment pore waters. The existing Canadian and U.S. Environmental Protection Agencies test procedures using sea urchin (and sand dollar) gametes allow for sample salinity adjustment using either brine or dry salts. Moreover, these procedures also allow for the use of either natural or synthetic marine water for culturing/holding test organisms and for full-scale testing. At present, it is unclear to what extent these variables affect test results for whole effluents. The test methods simply state that there are no data available and that the use of artificial dry sea salts should be considered provisional. We conducted a series of concurrent experiments aimed at comparing the two different treatments of sample salinity adjustment and the use of natural versus synthetic seawater in order to test these assumptions and evaluate effects on the estimated end points generated by the sea urchin fertilization sublethal toxicity test. Results from these experiments indicated that there is no significant difference in test end points when dry salts or brine are used for sample salinity adjustment. Similarly, results obtained from parallel (split-sample) industrial effluent tests with natural and artificial seawater suggest that both dilution waters produce similar test results. However, data obtained from concurrent tests with the reference toxicant, copper sulfate, showed higher variability and greater sensitivity when using natural seawater as control/dilution water.
Graphical Tests for Power Comparison of Competing Designs.
Hofmann, H; Follett, L; Majumder, M; Cook, D
2012-12-01
Lineups have been established as tools for visual testing similar to standard statistical inference tests, allowing us to evaluate the validity of graphical findings in an objective manner. In simulation studies lineups have been shown as being efficient: the power of visual tests is comparable to classical tests while being much less stringent in terms of distributional assumptions made. This makes lineups versatile, yet powerful, tools in situations where conditions for regular statistical tests are not or cannot be met. In this paper we introduce lineups as a tool for evaluating the power of competing graphical designs. We highlight some of the theoretical properties and then show results from two studies evaluating competing designs: both studies are designed to go to the limits of our perceptual abilities to highlight differences between designs. We use both accuracy and speed of evaluation as measures of a successful design. The first study compares the choice of coordinate system: polar versus cartesian coordinates. The results show strong support in favor of cartesian coordinates in finding fast and accurate answers to spotting patterns. The second study is aimed at finding shift differences between distributions. Both studies are motivated by data problems that we have recently encountered, and explore using simulated data to evaluate the plot designs under controlled conditions. Amazon Mechanical Turk (MTurk) is used to conduct the studies. The lineups provide an effective mechanism for objectively evaluating plot designs.
Evaluation of an oil-debris monitoring device for use in helicopter transmissions
NASA Technical Reports Server (NTRS)
Lewicki, David G.; Blanchette, Donald M.; Biron, Gilles
1992-01-01
Experimental tests were performed on an OH-58A helicopter main-rotor transmission to evaluate an oil-debris monitoring device (ODMD). The tests were performed in the NASA 500-hp Helicopter Transmission Test Stand. Five endurance tests were run as part of a U.S. Navy/NASA/Army advanced lubricants program. The tests were run at 100 percent design speed, 117-percent design torque, and 121 C (250 F) oil inlet temperature. Each test lasted between 29 and 122 hr. The oils that were used conformed to MIL-L-23699 and DOD-L-85734 specifications. One test produced a massive sun-gear fatigue failure; another test produced a small spall on one sun-gear tooth; and a third test produced a catastrophic planet-bearing cage failure. The ODMD results were compared with oil spectroscopy results. The capability of the ODMD to detect transmission component failures was not demonstrated. Two of the five tests produced large amounts of debris. For these two tests, two separate ODMD sensors failed, possibly because of prolonged exposure to relatively high oil temperatures. One test produced a small amount of debris and was not detected by the ODMD or by oil spectroscopy. In general, the ODMD results matched the oil spectroscopy results. The ODMD results were extremely sensitive to oil temperature and flow rate.
Shinkins, Bethany; Yang, Yaling; Abel, Lucy; Fanshawe, Thomas R
2017-04-14
Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1) what evidence aside from test accuracy was searched for and synthesised, 2) which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3) how/whether threshold effects were explored, 4) how the potential dependency between multiple tests in a pathway was accounted for, and 5) for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings. The uptake of appropriate meta-analysis methods for synthesising evidence on diagnostic test accuracy in UK NIHR HTAs has improved in recent years. Future research should focus on other evidence requirements for cost-effectiveness assessment, threshold effects for quantitative tests and the impact of multiple diagnostic tests.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-05
...] International Conference on Harmonisation; Guidance on Q4B Evaluation and Recommendation of Pharmacopoeial Texts... Recommendation of Pharmacopoeial Texts for Use in the ICH Regions; Annex 7: Dissolution Test General Chapter... results of the ICH Q4B evaluation of the Dissolution Test General Chapter harmonized text from each of the...
ERIC Educational Resources Information Center
Sieverts, Eric G.; And Others
1993-01-01
Reports on tests evaluating nine microcomputer software packages designed for information storage and retrieval: BRS-Search, dtSearch, InfoBank, Micro-OPC, Q&A, STN-PFS, Strix, TINman, and ZYindex. Tables and narrative evaluations detail results related to security, hardware, user features, search capability, indexing, input, maintenance of files,…
[Impact of a training model for the Child Development Evaluation Test in primary care].
Rizzoli-Córdoba, Antonio; Delgado-Ginebra, Ismael; Cruz-Ortiz, Leopoldo Alfonso; Baqueiro-Hernández, César Iván; Martain-Pérez, Itzamara Jacqueline; Palma-Tavera, Josuha Alexander; Villasís-Keever, Miguel Ángel; Reyes-Morales, Hortensia; O'Shea-Cuevas, Gabriel; Aceves-Villagrán, Daniel; Carrasco-Mendoza, Joaquín; Antillón-Ocampo, Fátima Adriana; Villagrán-Muñoz, Víctor Manuel; Halley-Castillo, Elizabeth; Vargas-López, Guillermo; Muñoz-Hernández, Onofre
The Child Development Evaluation (CDE) Test is a screening tool designed and validated in Mexico for the early detection of child developmental problems. For professionals who will be administering the test in primary care facilities, previous acquisition of knowledge about the test is required in order to generate reliable results. The aim of this work was to evaluate the impact of a training model for primary care workers from different professions through the comparison of knowledge acquired during the training course. The study design was a before/after type considering the participation in a training course for the CDE test as the intervention. The course took place in six different Mexican states from October to December 2013. The same questions were used before and after. There were 394 participants included. Distribution according to professional profile was as follows: general physicians 73.4%, nursing 7.7%, psychology 7.1%, nutrition 6.1% and other professions 5.6%. The questions with the lowest correct answer rates were associated with the scoring of the CDE test. In the initial evaluation, 64.9% obtained a grade lower than 20 compared with 1.8% in the final evaluation. In the initial evaluation only 1.8% passed compared with 75.15% in the final evaluation. The proposed model allows the participants to acquire general knowledge about the CDE Test. To improve the general results in future training courses, it is required to reinforce during training the scoring and interpretation of the test together with the previous lecture of the material by the participants. Copyright © 2015 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.
Evaluation of the intelligent cruise control system : volume 1 : study results
DOT National Transportation Integrated Search
1999-10-01
The Intelligent Cruise Control (ICC) system evaluation was based on an ICC Field Operational Test (FOT) performed in Michigan. The FOT involved 108 volunteers recruited to drive ten ICC-equipped Chrysler Concordes. Testing was initiated in July 1996 ...
DIRECT operational field test evaluation natural use study. Part 1, Subject stated response
DOT National Transportation Integrated Search
1998-08-01
This report presents evaluation results from the Subject Stated Response portion (Part I) of the Natural Use Study of the DIRECT (Driver Information Radio using Experimental Communication : Technologies) operational test sponsored by the Michigan Dep...
Travtek Evaluation Safety Study
DOT National Transportation Integrated Search
1996-02-01
One of the major evaluation goals of the TravTek operational test was to assess the safety impact of the TravTek system as implemented in Orlando, Florida during the 1 -year deployment phase. Also, the results of the TravTek operational test, with re...
Wide Panel Testing Technique for Evaluating Repair Weld Strengths
NASA Technical Reports Server (NTRS)
Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.
1998-01-01
This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.
Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles
2011-06-01
This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program's results show that an increased focus on mobile outreach using rapid testing, incentives and health information technology tools may improve program acceptability, quality, productivity and timeliness of reports. This article describes program design decisions based on continuous quality assessment efforts. It also examines the impact of the Computer Assessment and Risk Reduction Education computer tool on HIV testing rates, staff perception of counseling quality, program productivity, and on the timeliness of evaluation reports. The article concludes with a discussion of implications for programmatic responses to the Centers for Disease Control and Prevention's HIV testing recommendations.
Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles
2016-01-01
This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program’s results show that an increased focus on mobile outreach using rapid testing, incentives and health information technology tools may improve program acceptability, quality, productivity and timeliness of reports. This article describes program design decisions based on continuous quality assessment efforts. It also examines the impact of the Computer Assessment and Risk Reduction Education computer tool on HIV testing rates, staff perception of counseling quality, program productivity, and on the timeliness of evaluation reports. The article concludes with a discussion of implications for programmatic responses to the Centers for Disease Control and Prevention’s HIV testing recommendations. PMID:21689041
NASA TEERM Hexavalent Chrome Alternatives Projects
NASA Technical Reports Server (NTRS)
Rothgeb, Matt
2009-01-01
This slide presentation reviews the NASA/DOD projects to select an alternative to hexavalent chrome in the aerospace industry. The Phase I process of the project performed: (1) Evaluation and testing of non-chromated coating systems as replacements for hexavalent chrome coatings in aircraft and aerospace applications. (2) Testing of coating systems to DoD and NASA specifications for corrosion resistance and adhesion. (3) Bare corrosion resistance and atmospheric exposure will be focus areas of Phase II Testing. The description includes a chart that summarizes the 3000 hour salt fog test results. The second phase of the project includes (1) Evaluation and testing of coating systems that do not contain hexavalent chrome as replacements for aerospace applications. (2) Evaluation of coatings at Beach Test Site and Launch Complex 39B (3) Evaluation of non-chrome coatings for electronic housings (bare corrosion resistance and electrical impedance) is a part of this round of testing. This project was performed for the Technology Evaluation for Environmental Risk Mitigation (TEERM)
Yang, Zixuan; Kan, Bo; Li, Jinxu; Qiao, Lijie; Volinsky, Alex A; Su, Yanjing
2017-11-14
Hydrostatic pressure effects on pitting initiation and propagation in X70 steel are investigated by evaluating metastable pitting probability using electrochemical methods and immersion corrosion tests in containing chlorine ion solution. Potentiodynamic tests indicated that hydrostatic pressure can decrease the breakdown potential and lead to a reduced transpassivity region. Metastable test results revealed that hydrostatic pressure can increase metastable pitting formation frequency and promote stabilization of metastable pitting growth. Electrochemical impedance spectroscopy (EIS) results indicate that Hydrostatic pressure decreases the charge transfer resistance and increases the dissolution rate within the cavities. Corrosion test results also indicated that pitting initiation and propagation are accelerated by hydrostatic pressure. Result validity was verified by evaluating metastable pitting to predict pitting corrosion resistance.
Yang, Zixuan; Kan, Bo; Li, Jinxu; Su, Yanjing; Qiao, Lijie; Volinsky, Alex A.
2017-01-01
Hydrostatic pressure effects on pitting initiation and propagation in X70 steel are investigated by evaluating metastable pitting probability using electrochemical methods and immersion corrosion tests in containing chlorine ion solution. Potentiodynamic tests indicated that hydrostatic pressure can decrease the breakdown potential and lead to a reduced transpassivity region. Metastable test results revealed that hydrostatic pressure can increase metastable pitting formation frequency and promote stabilization of metastable pitting growth. Electrochemical impedance spectroscopy (EIS) results indicate that Hydrostatic pressure decreases the charge transfer resistance and increases the dissolution rate within the cavities. Corrosion test results also indicated that pitting initiation and propagation are accelerated by hydrostatic pressure. Result validity was verified by evaluating metastable pitting to predict pitting corrosion resistance. PMID:29135912
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durham, M.D.
Several tasks have been completed in a program to evaluate additives to improve fine particle collection in electrostatic precipitators. Screening tests and laboratory evaluations of additives are summarized in this report. Over 20 additives were evaluated; four were found to improve flyash precipitation rates. The Insitec particle analyzer was also evaluated; test results show that the analyzer will provide accurate sizing and counting information for particles in the size range of {le} 10 {mu}m dia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durham, M.D.
Several tasks have been completed in a program to evaluate additives to improve fine particle collection in electrostatic precipitators. Screening tests and laboratory evaluations of additives are summarized in this report. Over 20 additives were evaluated; four were found to improve flyash precipitation rates. The Insitec particle analyzer was also evaluated; test results show that the analyzer will provide accurate sizing and counting information for particles in the size range of [le] 10 [mu]m dia.
Evaluation of composite components on the Bell 206L and Sikorsky S-76 helicopters
NASA Technical Reports Server (NTRS)
Baker, Donald J.
1990-01-01
Progress on two programs to evaluate structural composite components in flight service on Bell 206L and Sikorsky S-76 commercial helicopters is described. Forty ship sets of composite components that include the litter door, baggage door, forward fairing, and vertical fin have been installed on Bell Model 206L helicopters that are operating in widely different climates. Component installation started in 1981 and selected components were removed and tested at prescribed intervals over a ten year evaluation. Four horizontal stabilizers and eleven tail rotor spars that are production components on the S-76 helicopter were tested after prescribed periods of service to determine the effects of the operating environment on their performance. Concurrent with the flight evaluation, materials used to fabricate the components were exposed in ground racks and tested at specified intervals to determine the effects of outdoor environments. Results achieved from 123,000 hours of accumulated service on the Bell 206L components and 53,000 hours on the Sikorsky S-76 components are reported. Seventy-eight Bell 206L components were removed and tested statically. Results of seven years of ground exposure of materials used to fabricate the Bell 206L components are presented. Results of tests on four Sikorsky S-76 horizontal stabilizers and eleven tail rotor spars are also presented. Panels of material used to fabricate the Sikorsky S-76 components that were exposed for six years were tested and results are presented.
Talip, Whadi-ah; Steyn, Nelia P; Visser, Marianne; Charlton, Karen E; Temple, Norman
2003-09-01
We wanted to develop and validate a test that assesses the knowledge and practices of health professionals (HPs) with regard to the role of nutrition, physical activity, and smoking cessation (lifestyle modification) in chronic diseases of lifestyle. A descriptive cross-sectional validation study was carried out. The validation design consisted of two phases, namely 1) test planning and development and 2) test evaluation. The study sample consisted of five groups of HPs: dietitians, dietetic interns, general practitioners, medical students, and nurses. The overall response rate was 58%, resulting in a sample size of 186 participants. A test was designed to evaluate the knowledge and practices of HPs. The test was first evaluated by an expert group to ensure content, construct, and face validity. Thereafter, the questionnaire was tested on five groups of HPs to test for criterion validity. Internal consistency was evaluated by Cronbach's alpha. An expert panel ensured content, construct, and face validity of the test. Groups with the most training and exposure to nutrition (dietitians and dietetic interns) had the highest group mean score, ranging from 61% to 88%, whereas those with limited nutrition training (general practitioners, medical students, and nurses) had significantly lower scores, ranging from 26% to 80%. This result demonstrated criterion validity. Internal consistency of the overall test demonstrated a Cronbach's alpha of 0.99. Most HPs identified the mass media as their main source of information on lifestyle modification. These HPs also identified lack of time, lack of patient compliance, and lack of knowledge as barriers that prevent them from providing counseling on lifestyle modification. The results of this study showed that this test instrument identifies groups of health professionals with adequate training (knowledge) in lifestyle modification and those who require further training (knowledge).
Use of the Marshall Space Flight Center solar simulator in collector performance evaluation
NASA Technical Reports Server (NTRS)
Humphries, W. R.
1978-01-01
Actual measured values from simulator checkout tests are detailed. Problems encountered during initial startup are discussed and solutions described. Techniques utilized to evaluate collector performance from simulator test data are given. Performance data generated in the simulator are compared to equivalent data generated during natural outdoor testing. Finally, a summary of collector performance parameters generated to date as a result of simulator testing are given.
Evaluation of anomalies observed on film from S-190A flight system calibration test
NASA Technical Reports Server (NTRS)
Bourque, P. F.; Perry, L.; Sauer, G. E.
1975-01-01
Due to a persistent problem of scratched film from testing of the Skylab S-190A system, a series of tests were designed to identify the cause of the film scratching. The procedures followed in this test for pretest handling and packaging of the film, the makeup of the rolls for processing, and the results of the processed film evaluation are reported.
Interexaminer reliability in physical examination of patients with low back pain.
Strender, L E; Sjöblom, A; Sundell, K; Ludwig, R; Taube, A
1997-04-01
Seventy-one patients with low back pain were examined by two physiotherapists (50 patients) and two physicians (21 patients). The two physiotherapists had worked together for many years, but the two physicians had not. The interexaminer reliability of the clinical tests included in the physical examination was evaluated. To evaluate the interexaminer reliability of clinical tests used in the physical examination of patients with low back pain under ideal circumstances, which was the case for the physiotherapists. Numerous clinical tests are used in the evaluation of patients with low back pain. To reach the correct diagnosis, only tests with an acceptable validity and reliability should be used. Previous studies have mainly shown low reliability. It is important that clinical tests not be rejected because of low reliability caused by differences between examiners in performance of the examination and in their definition of normal results. Two examiners, either two physiotherapists or two physicians, independently examined patients with low back pain. In approximately half of the clinical tests studied, an acceptable reliability was demonstrated. On the basis of the physiotherapists series, the reliability was acceptable for a number of clinical tests that are used in the evaluation of patients with low back pain. The results suggest that clinical tests should be standardized to a much higher degree than they are today.
Martin, N H; Ranieri, M L; Murphy, S C; Ralyea, R D; Wiedmann, M; Boor, K J
2011-03-01
Analytical tools that accurately predict the performance of raw milk following its manufacture into commercial food products are of economic interest to the dairy industry. To evaluate the ability of currently applied raw milk microbiological tests to predict the quality of commercially pasteurized fluid milk products, samples of raw milk and 2% fat pasteurized milk were obtained from 4 New York State fluid milk processors for a 1-yr period. Raw milk samples were examined using a variety of tests commonly applied to raw milk, including somatic cell count, standard plate count, psychrotrophic bacteria count, ropy milk test, coliform count, preliminary incubation count, laboratory pasteurization count, and spore pasteurization count. Differential and selective media were used to identify groups of bacteria present in raw milk. Pasteurized milk samples were held at 6°C for 21 d and evaluated for standard plate count, coliform count, and sensory quality throughout shelf-life. Bacterial isolates from select raw and pasteurized milk tests were identified using 16S ribosomal DNA sequencing. Linear regression analysis of raw milk test results versus results reflecting pasteurized milk quality consistently showed low R(2) values (<0.45); the majority of R(2) values were <0.25, indicating small relationship between the results from the raw milk tests and results from tests used to evaluate pasteurized milk quality. Our findings suggest the need for new raw milk tests that measure the specific biological barriers that limit shelf-life and quality of fluid milk products. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Fire safety evaluation of aircraft lavatory and cargo compartments
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.; Hilado, C. J.; Anderson, R. A.; Tustin, E.; Arnold, D. E.; Gaume, J. G.; Binding, A. T.; Mikeska, J. L.
1975-01-01
Large-scale aircraft lavatory and cargo compartment fire tests are described. Tests were conducted to evaluate the effectiveness of these compartments to contain fire and smoke. Two tests were conducted and are detailed. Test 1 involved a production Boeing 747 lavatory of the latest design installed in an enclosure outside the aircraft, to collect gases and expose animals to these gases. Results indicate that the interior of the lavatory was completely burned, evolving smoke and combustion products in the enclosure. Test 2 involved a simulated Douglas DC-10 cargo compartment retro-fitted with standard fiberglass liner. The fire caused excessive damage to the liner and burned through the ceiling in two areas. Test objectives, methods, materials, and results are presented and discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chambon, Paul H.; Deter, Dean D.
2016-07-01
xiii ABSTRACT The goal of this project is to develop and evaluate powertrain test procedures that can accurately simulate real-world operating conditions, and to determine greenhouse gas (GHG) emissions of advanced medium- and heavy-duty engine and vehicle technologies. ORNL used their Vehicle System Integration Laboratory to evaluate test procedures on a stand-alone engine as well as two powertrains. Those components where subjected to various drive cycles and vehicle conditions to evaluate the validity of the results over a broad range of test conditions. Overall, more than 1000 tests were performed. The data are compiled and analyzed in this report.
The effectiveness of the 1996 Wood Magic Science Fair as an experiential field trip
NASA Astrophysics Data System (ADS)
Pearson, Robert Wayne
In response to the need for evaluating the effectiveness of the 1996 Wood Magic Science Fair (WMSF) at Mississippi State University's Forest and Wildlife Research Center/Forest Products Laboratory, two tests were developed. One test was designed for third-grade students and one for fourth-grade students who would attend the WMSF. Both tests have multiple choice answers and contained thirteen questions each. Five of the questions addressed general issues of the forest products industry that would be mentioned in an opening video but not stressed in the oral presentations of the WMSF. The students would have no active involvement in these presentations. These general issue questions represent passive involvement teaching. The eight remaining questions addressed specific information that would be stressed in the WMSF oral presentations and would allow students to actively participate in the presentations. The participation of the students in these presentations represents participatory teaching. The tests were given to the students (third and fourth grades) both before they attended the fair as a pre-test and after their attendance as a post-test with the only difference being that the multiple choice answers were arranged in a different order. Classroom teachers administered the tests to the students. The test results were evaluated for each class individually. Each question was evaluated and the results recorded in a table. The general information questions were grouped together as were the specific information questions. This grouping allowed a comparison to be made between passive and participatory learning. The results from the tests will help those making the science fair presentations evaluate their materials and methods. Statistical analysis of the results would indicate which questions had a significant change in the number of correct answers between the pre-test and post-test. This information will help the Fair planners and presenters in developing future programs.
NASA Technical Reports Server (NTRS)
Slater, Richard
1996-01-01
A joint U.S./Russian film test was conducted during MIR Mission 18 to evaluate the effects of radiation on photographic film during long-duration space flights. Two duplicate sets of film were flown on this MIR mission: one set was processed and evaluated by the NASA/JSC Photographic Laboratory, and the other by the RKK Energia's Photographic Laboratory in Moscow. This preliminary report includes only the results of the JSC evaluation (excluding the SN-10 film which was not available for evaluation at the time this report was written). The final report will include an evaluation by JSC of the SN-10 film and an evaluation of the test data by the RKK Energia. ISC's evaluation of the test data showed the positive film flown was damaged very little when exposed to approximately 8 rads of radiation. Two of the three negative films were significantly damaged and the third film was damaged only moderately.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slater, R.
1996-04-01
A joint U.S./Russian film test was conducted during MIR Mission 18 to evaluate the effects of radiation on photographic film during long-duration space flights. Two duplicate sets of film were flown on this MIR mission: one set was processed and evaluated by the NASA/JSC Photographic Laboratory, and the other by the RKK Energia`s Photographic Laboratory in Moscow. This preliminary report includes only the results of the JSC evaluation (excluding the SN-10 film which was not available for evaluation at the time this report was written). The final report will include an evaluation by JSC of the SN-10 film and anmore » evaluation of the test data by the RKK Energia. ISC`s evaluation of the test data showed the positive film flown was damaged very little when exposed to approximately 8 rads of radiation. Two of the three negative films were significantly damaged and the third film was damaged only moderately.« less
Kuselman, Ilya; Pennecchi, Francesca R; da Silva, Ricardo J N B; Hibbert, D Brynn
2017-11-01
The probability of a false decision on conformity of a multicomponent material due to measurement uncertainty is discussed when test results are correlated. Specification limits of the components' content of such a material generate a multivariate specification interval/domain. When true values of components' content and corresponding test results are modelled by multivariate distributions (e.g. by multivariate normal distributions), a total global risk of a false decision on the material conformity can be evaluated based on calculation of integrals of their joint probability density function. No transformation of the raw data is required for that. A total specific risk can be evaluated as the joint posterior cumulative function of true values of a specific batch or lot lying outside the multivariate specification domain, when the vector of test results, obtained for the lot, is inside this domain. It was shown, using a case study of four components under control in a drug, that the correlation influence on the risk value is not easily predictable. To assess this influence, the evaluated total risk values were compared with those calculated for independent test results and also with those assuming much stronger correlation than that observed. While the observed statistically significant correlation did not lead to a visible difference in the total risk values in comparison to the independent test results, the stronger correlation among the variables caused either the total risk decreasing or its increasing, depending on the actual values of the test results. Copyright © 2017 Elsevier B.V. All rights reserved.
Predicting Middle Level State Standardized Test Results Using Family and Community Demographic Data
ERIC Educational Resources Information Center
Tienken, Christopher H.; Colella, Anthony; Angelillo, Christian; Fox, Meredith; McCahill, Kevin R.; Wolfe, Adam
2017-01-01
The use of standardized test results to drive school administrator evaluations pervades education policymaking in more than 40 states. However, the results of state standardized tests are strongly influenced by non-school factors. The models of best fit (n = 18) from this correlational, explanatory, longitudinal study predicted accurately the…
Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.
Doyle, Kelly; Strathmann, Frederick G
2017-02-01
This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.
Evaluation of the Mack Intelligent Vehicle Field Operational Test: September 2006
DOT National Transportation Integrated Search
2006-09-01
This report presents the final results of an independent evaluation of the U.S. Department of Transportation (USDOT) Mack Intelligent Vehicle Initiative (IVI) Field Operational Test (FOT). The IVI is a cooperative effort to conduct FOTs of advanced i...
Small Engine Technology (Set) Task 8 Aeroelastic Prediction Methods
NASA Technical Reports Server (NTRS)
Eick, Chris D.; Liu, Jong-Shang
1998-01-01
AlliedSignal Engines, in cooperation with NASA LeRC, completed an evaluation of recently developed aeroelastic computer codes using test cases from the AlliedSignal Engines fan blisk database. Test data for this task includes strain gage, light probe, performance, and steady-state pressure information obtained for conditions where synchronous or flutter vibratory conditions were found to occur. Aeroelastic codes evaluated include the quasi 3-D UNSFLO (developed at MIT and modified to include blade motion by AlliedSignal), the 2-D FREPS (developed by NASA LeRC), and the 3-D TURBO-AE (under development at NASA LeRC). Six test cases each where flutter and synchronous vibrations were found to occur were used for evaluation of UNSFLO and FREPS. In addition, one of the flutter cases was evaluated using TURBO-AE. The UNSFLO flutter evaluations were completed for 75 percent radial span and provided good agreement with the experimental test data. Synchronous evaluations were completed for UNSFLO but further enhancement needs to be added to the code before the unsteady pressures can be used to predict forced response vibratory stresses. The FREPS evaluations were hindered as the steady flow solver (SFLOW) was unable to converge to a solution for the transonic flow conditions in the fan blisk. This situation resulted in all FREPS test cases being attempted but no results were obtained during the present program. Currently, AlliedSignal is evaluating integrating FREPS with our existing steady flow solvers to bypass the SFLOW difficulties. ne TURBO-AE steady flow solution provided an excellent match with the AlliedSignal Engines calibrated DAWES 3-D viscous solver. Finally, the TURBO-AE unsteady analyses also matched experimental observations by predicting flutter for the single test case evaluated.
Physical Test Prototypes Based on Microcontroller
NASA Astrophysics Data System (ADS)
Paramitha, S. T.
2017-03-01
The purpose of this study was to produce a prototype of a physical test-based microcontroller. The research method uses the research and development of the Borg and gall. The procedure starts from the study; research and information collecting, planning, develop preliminary form of product, preliminary field testing, main product revision, playing field testing, operational product revision, field operational testing, final product revision, dissemination and implementation. Validation of the product, obtained through expert evaluation; test products of small scale and large scale; effectiveness test; evaluation of respondents. The results showed that the eligibility assessment of prototype products based physical tests microcontroller. Based on the ratings of seven experts showed that 87% included in the category of “very good” and 13% included in the category of “good”. While the effectiveness of the test results showed that 1). The results of the experimental group to test sit-ups increase by 40% and the control group by 15%. 2). The results of the experimental group to test push-ups increased by 30% and the control group by 10%. 3). The results of the experimental group to test the Back-ups increased by 25% and the control group by 10%. With a significant value of 0.002 less than 0.05, product means a physical test prototype microcontroller based, proven effective in improving the results of physical tests. Conclusions and recommendations; Product physical microcontroller-based assays, can be used to measure the physical tests of pushups, sit ups, and back-ups.
NASA Technical Reports Server (NTRS)
Knox, James C.; Gauto, Hernando; Miller, Lee A.
2015-01-01
The International Space Station Carbon Dioxide Removal Assembly uses zeolite 5A molecular sieve material packed into beds for the capture of cabin CO2. The beds are cyclically heated to drive off the CO2 and restore the removal capacity. Over time, the sorbent material has been found to break down resulting in dust that restricts flow through the beds. Humidity adsorbed in the 5A zeolite when it is heated is a suspected cause of this sorbent degradation. To evaluate the impact of adsorbed water during thermal cycling, the Hydrothermal Stability Test was developed. The test configuration provides comparative side-by-side flow restriction data for two sorbent materials at specifically controlled humidity levels. While the initial focus of the testing is on 5A zeolite materials currently used on the ISS, the system will also be used to evaluate future candidate materials. This paper describes the approach, the test system, current results, and future testing.
Narita, Kazuto; Ishii, Yuuki; Vo, Phuc Thi Hong; Nakagawa, Fumiko; Ogata, Shinichi; Yamashita, Kunihiko; Kojima, Hajime; Itagaki, Hiroshi
2018-01-01
Recently, animal testing has been affected by increasing ethical, social, and political concerns regarding animal welfare. Several in vitro safety tests for evaluating skin sensitization, such as the human cell line activation test (h-CLAT), have been proposed. However, similar to other tests, the h-CLAT has produced false-negative results, including in tests for acid anhydride and water-insoluble chemicals. In a previous study, we demonstrated that the cause of false-negative results from phthalic anhydride was hydrolysis by an aqueous vehicle, with IL-8 release from THP-1 cells, and that short-time exposure to liquid paraffin (LP) dispersion medium could reduce false-negative results from acid anhydrides. In the present study, we modified the h-CLAT by applying this exposure method. We found that the modified h-CLAT is a promising method for reducing false-negative results obtained from acid anhydrides and chemicals with octanol-water partition coefficients (LogK ow ) greater than 3.5. Based on the outcomes from the present study, a combination of the original and the modified h-CLAT is suggested for reducing false-negative results. Notably, the combination method provided a sensitivity of 95% (overall chemicals) or 93% (chemicals with LogK ow > 2.0), and an accuracy of 88% (overall chemicals) or 81% (chemicals with LogK ow > 2.0). We found that the combined method is a promising evaluation scheme for reducing false-negative results seen in existing in vitro skin-sensitization tests. In the future, we expect a combination of original and modified h-CLAT to be applied in a newly developed in vitro test for evaluating skin sensitization.
The use of a battery of tracking tests in the quantitative evaluation of neurological function
NASA Technical Reports Server (NTRS)
Repa, B. S.; Albers, J. W.; Potvin, A. R.; Tourtellotte, W. W.
1972-01-01
A tracking test battery has been applied in a drug trail designed to compare the efficacy of L-DOPA and amantadine to that of L-DOPA and placebo in the treatment of 28 patients with Parkinson's disease. The drug trial provided an ideal opportunity for objectively evaluating the usefulness of tracking tests in assessing changes in neurologic function. Evaluating changes in patient performance resulting from disease progression and controlled clinical trials is of great importance in establishing effective treatment programs.
NASA Astrophysics Data System (ADS)
Vuori, Tero; Olkkonen, Maria
2006-01-01
The aim of the study is to test both customer image quality rating (subjective image quality) and physical measurement of user behavior (eye movements tracking) to find customer satisfaction differences in imaging technologies. Methodological aim is to find out whether eye movements could be quantitatively used in image quality preference studies. In general, we want to map objective or physically measurable image quality to subjective evaluations and eye movement data. We conducted a series of image quality tests, in which the test subjects evaluated image quality while we recorded their eye movements. Results show that eye movement parameters consistently change according to the instructions given to the user, and according to physical image quality, e.g. saccade duration increased with increasing blur. Results indicate that eye movement tracking could be used to differentiate image quality evaluation strategies that the users have. Results also show that eye movements would help mapping between technological and subjective image quality. Furthermore, these results give some empirical emphasis to top-down perception processes in image quality perception and evaluation by showing differences between perceptual processes in situations when cognitive task varies.
Collaborative Testing: An Effective Invitational Strategy for High-Stakes Testing in Nursing.
Green, Rebecca; Worthey, Terri; Kerven, Jenny
2018-05-01
A collaborative testing intervention was designed as an application of the invitational education model in an undergraduate nursing course. The purpose of this study was to evaluate the effect of collaborative testing on examination scores and knowledge retention of course content and to evaluate students' feelings about the collaborative testing process. A quasi-experimental design was used to evaluate the effect of collaborative testing on examination scores and knowledge retention among undergraduate nursing students in a public health course (N = 106). A descriptive survey was used to evaluate students' perceptions of the collaborative testing intervention. Collaborative testing increased examination scores and facilitated knowledge retention. Students' perceptions of the intervention were positive. Invitational strategies, such as collaborative testing, may result in measurably better outcomes, such as better examination scores and improved knowledge retention. Rigor does not need to be a barrier to invitational learning and, in fact, it may be complemented and enhanced by it. [J Nurs Educ. 2018;57(5):291-295.]. Copyright 2018, SLACK Incorporated.
Test and analysis of Celion 3000/PMR-15, graphite/polyimide bonded composite joints: Data report
NASA Technical Reports Server (NTRS)
Cushman, J. B.; Mccleskey, S. F.; Ward, S. H.
1982-01-01
Standard single lap, double lap and symmetric step lap bonded joints of Celion 3000/PMR-15 graphite/polyimide composite were evaluated. Composite to composite and composite to titanium joints were tested at 116 K (-250 F), 294 K (70 F) and 561 K (550 F). Joint parameters evaluated are lap length, adherend thickness, adherend axial stiffness, lamina stacking sequence and adherend tapering. Advanced joint concepts were examined to establish the change in performance of preformed adherends, scalloped adherends and hybrid systems. The material properties of the high temperature adhesive, designated A7F, used for bonding were established. The bonded joint tests resulted in interlaminar shear or peel failures of the composite and there were very few adhesive failures. Average test results agree with expected performance trends for the various test parameters. Results of finite element analyses and of test/analysis correlations are also presented.
Seidman, Seth J; Bekdash, Omar; Guag, Joshua; Mehryar, Maryam; Booth, Paul; Frisch, Paul
2014-08-03
The use of radio frequency identification (RFID) systems in healthcare is increasing, and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have demonstrated that RFID systems can interfere with medical devices; however, the majority of past studies relied on time-consuming and burdensome test schemes based on ad hoc test methods applied to individual RFID systems. This paper presents the results of using an RFID simulator that allows for faster evaluation of RFID-medical device EMC against a library of RFID test signals at various field strengths. The results of these tests demonstrate the feasibility and adequacy of simulator testing and can be used to support its incorporation into applicable consensus standards. This work can aid the medical device community in better assessing the risks associated with medical device exposure to RFID.
Evaluation of a Singular Value Decomposition Approach for Impact Dynamic Data Correlation
NASA Technical Reports Server (NTRS)
Horta, Lucas G.; Lyle, Karen H.; Lessard, Wendy B.
2003-01-01
Impact dynamic tests are used in the automobile and aircraft industries to assess survivability of occupants during crash, to assert adequacy of the design, and to gain federal certification. Although there is no substitute for experimental tests, analytical models are often developed and used to study alternate test conditions, to conduct trade-off studies, and to improve designs. To validate results from analytical predictions, test and analysis results must be compared to determine the model adequacy. The mathematical approach evaluated in this paper decomposes observed time responses into dominant deformation shapes and their corresponding contribution to the measured response. To correlate results, orthogonality of test and analysis shapes is used as a criterion. Data from an impact test of a composite fuselage is used and compared to finite element predictions. In this example, the impact response was decomposed into multiple shapes but only two dominant shapes explained over 85% of the measured response
Evaluation of direct-to-consumer low-volume lab tests in healthy adults
Kidd, Brian A.; Hoffman, Gabriel; Zimmerman, Noah; Li, Li; Morgan, Joseph W.; Glowe, Patricia K.; Botwin, Gregory J.; Parekh, Samir; Babic, Nikolina; Doust, Matthew W.; Stock, Gregory B.; Schadt, Eric E.; Dudley, Joel T.
2016-01-01
BACKGROUND. Clinical laboratory tests are now being prescribed and made directly available to consumers through retail outlets in the USA. Concerns with these test have been raised regarding the uncertainty of testing methods used in these venues and a lack of open, scientific validation of the technical accuracy and clinical equivalency of results obtained through these services. METHODS. We conducted a cohort study of 60 healthy adults to compare the uncertainty and accuracy in 22 common clinical lab tests between one company offering blood tests obtained from finger prick (Theranos) and 2 major clinical testing services that require standard venipuncture draws (Quest and LabCorp). Samples were collected in Phoenix, Arizona, at an ambulatory clinic and at retail outlets with point-of-care services. RESULTS. Theranos flagged tests outside their normal range 1.6× more often than other testing services (P < 0.0001). Of the 22 lab measurements evaluated, 15 (68%) showed significant interservice variability (P < 0.002). We found nonequivalent lipid panel test results between Theranos and other clinical services. Variability in testing services, sample collection times, and subjects markedly influenced lab results. CONCLUSION. While laboratory practice standards exist to control this variability, the disparities between testing services we observed could potentially alter clinical interpretation and health care utilization. Greater transparency and evaluation of testing technologies would increase their utility in personalized health management. FUNDING. This work was supported by the Icahn Institute for Genomics and Multiscale Biology, a gift from the Harris Family Charitable Foundation (to J.T. Dudley), and grants from the NIH (R01 DK098242 and U54 CA189201, to J.T. Dudley, and R01 AG046170 and U01 AI111598, to E.E. Schadt). PMID:27018593
Evaluation tests of industrial vacuum bearings for space use
NASA Astrophysics Data System (ADS)
Obara, S.; Sasaki, A.; Haraguchi, M.; Imagawa, K.; Nishimura, M.; Kawashima, N.
2001-09-01
Tribological performance of industrial vacuum bearings was experimentally evaluated for space use. The bearings selected for investigation were an 8 mm bore-sized deep-groove ball bearing lubricated with a sputtered MoS2 film and that lubricated with an ion-plated Ag film, commercially delivered from three Japanese domestic bearing-manufacturers. Based on survey results of tribological requirements for the existing satellite mechanisms, four types of bearing tests were defined and conducted: a vacuum test at room temperature, an atmosphere-resistant test, a thermal vacuum test and a vibration test. In addition to these tests, variation in tribological performance of the industrial bearings was also investigated. The results of more than eighty tests demonstrated that the industrial vacuum bearings had sufficient lubrication lives with low frictional torque and their data were reasonably repeatable, indicating very good potentiality for space use.
Standard Procedures for Air Force Operational Test and Evaluation. Volume I. Appendices
1974-10-01
Participates in selected tests data for assessment of suitability Participates in the intepretation of and effectiveness, as practicable tet results...selected tests Interprels test results Inteprets test resultst ReplRorts to CNO the results of the "eports independent operational TI’ECIIEVAL assessment" v... films , lists, tapes, drawings, specifications. parts breakdowns, ctc. RAW DATA; ’The original form of data at the time it was recorded. DATA
NASA Astrophysics Data System (ADS)
Anderson, Gustave
2014-05-01
Unfortunately, there is no metric, nor set of metrics, that are both general enough to encompass all possible types of applications yet specific enough to capture the application and attack specific details. As a result we are left with ad-hoc methods for generating evaluations of the security of our systems. Current state of the art methods for evaluating the security of systems include penetration testing and cyber evaluation tests. For these evaluations, security professionals simulate an attack from malicious outsiders and malicious insiders. These evaluations are very productive and are able to discover potential vulnerabilities resulting from improper system configuration, hardware and software flaws, or operational weaknesses. We therefore propose the index of cyber integrity (ICI), which is modeled after the index of biological integrity (IBI) to provide a holistic measure of the health of a system under test in a cyber-environment. The ICI provides a broad base measure through a collection of application and system specific metrics. In this paper, following the example of the IBI, we demonstrate how a multi-metric index may be used as a holistic measure of the health of a system under test in a cyber-environment.
Towards an evaluation framework for Laboratory Information Systems.
Yusof, Maryati M; Arifin, Azila
Laboratory testing and reporting are error-prone and redundant due to repeated, unnecessary requests and delayed or missed reactions to laboratory reports. Occurring errors may negatively affect the patient treatment process and clinical decision making. Evaluation on laboratory testing and Laboratory Information System (LIS) may explain the root cause to improve the testing process and enhance LIS in supporting the process. This paper discusses a new evaluation framework for LIS that encompasses the laboratory testing cycle and the socio-technical part of LIS. Literature review on discourses, dimensions and evaluation methods of laboratory testing and LIS. A critical appraisal of the Total Testing Process (TTP) and the human, organization, technology-fit factors (HOT-fit) evaluation frameworks was undertaken in order to identify error incident, its contributing factors and preventive action pertinent to laboratory testing process and LIS. A new evaluation framework for LIS using a comprehensive and socio-technical approach is outlined. Positive relationship between laboratory and clinical staff resulted in a smooth laboratory testing process, reduced errors and increased process efficiency whilst effective use of LIS streamlined the testing processes. The TTP-LIS framework could serve as an assessment as well as a problem-solving tool for the laboratory testing process and system. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Crowe, S. B.; Kairn, T.; Middlebrook, N.; Sutherland, B.; Hill, B.; Kenny, J.; Langton, C. M.; Trapp, J. V.
2015-03-01
This study aimed to provide a detailed evaluation and comparison of a range of modulated beam evaluation metrics, in terms of their correlation with QA testing results and their variation between treatment sites, for a large number of treatments. Ten metrics including the modulation index (MI), fluence map complexity, modulation complexity score (MCS), mean aperture displacement (MAD) and small aperture score (SAS) were evaluated for 546 beams from 122 intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment plans targeting the anus, rectum, endometrium, brain, head and neck and prostate. The calculated sets of metrics were evaluated in terms of their relationships to each other and their correlation with the results of electronic portal imaging based quality assurance (QA) evaluations of the treatment beams. Evaluation of the MI, MAD and SAS suggested that beams used in treatments of the anus, rectum, head and neck were more complex than the prostate and brain treatment beams. Seven of the ten beam complexity metrics were found to be strongly correlated with the results from QA testing of the IMRT beams (p < 0.00008). For example, values of SAS (with multileaf collimator apertures narrower than 10 mm defined as ‘small’) less than 0.2 also identified QA passing IMRT beams with 100% specificity. However, few of the metrics are correlated with the results from QA testing of the VMAT beams, whether they were evaluated as whole 360° arcs or as 60° sub-arcs. Select evaluation of beam complexity metrics (at least MI, MCS and SAS) is therefore recommended, as an intermediate step in the IMRT QA chain. Such evaluation may also be useful as a means of periodically reviewing VMAT planning or optimiser performance.
Mixed-methods evaluation of a novel online STI results service.
Gibbs, Jo; Aicken, Catherine R H; Sutcliffe, Lorna J; Gkatzidou, Voula; Tickle, Laura J; Hone, Kate; Sadiq, S Tariq; Sonnenberg, Pam; Estcourt, Claudia S
2018-01-11
Evidence on optimal methods for providing STI test results is lacking. We evaluated an online results service, developed as part of an eSexual Health Clinic (eSHC). We evaluated the online results service using a mixed-methods approach within large exploratory studies of the eSHC. Participants were chlamydia- positive and negative users of online postal self-sampling services in six National Chlamydia Screening Programme (NCSP) areas and chlamydia-positive patients from two genitourinary medicine (GUM) clinics between 21 July 2014 and 13 March 2015. Participants received a discreetly worded National Health Service 'NHS no-reply' text message (SMS) informing them that their test results were ready and providing a weblink to a secure website. Participants logged in with their date of birth and mobile telephone or clinic number. Chlamydia-positive patients were offered online management. All interactions with the eSHC system were automatically logged and their timing recorded. Post-treatment, a service evaluation survey (n=152) and qualitative interviews (n=36) were conducted by telephone. Chlamydia-negative patients were offered a short online survey (n=274). Data were integrated. 92% (134/146) of NCSP chlamydia-positive patients, 82% (161/197) of GUM chlamydia-positive patients and 89% (1776/1997) of NCSP chlamydia-negative participants accessed test results within 7 days. 91% of chlamydia-positive patients were happy with the results service; 64% of those who had tested previously found the results service better or much better than previous experiences. 90% of chlamydia-negative survey participants agreed they would be happy to receive results this way in the future. Interviewees described accessing results with ease and appreciated the privacy and control the two-step process gave them. A discreet SMS to alert users/patients that results are available, followed by provision of results via a secure website, was highly acceptable, irrespective of test result and testing history. The eSHC results service afforded users privacy and control over when they viewed results without compromising access. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Small Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions
NASA Technical Reports Server (NTRS)
Broerman, Craig; Sweterlitsch, Jeffrey
2011-01-01
A principle concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has long been evaluated for use in this application and several programs are evaluating it for use in both a cabin as well as space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of small scale SA9T testing that was performed over a variety of test conditions and with a variety of trace contaminants. Testing evaluated the ability of SA9T media to sufficiently remove CO2 and H2O after exposure to a fully saturated trace contaminant at ambient conditions. Testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures during cyclic operation with a constant inlet contaminant load. In addition, testing evaluated the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream.
NASA Technical Reports Server (NTRS)
1971-01-01
The findings, conclusions, and recommendations relative to the investigations conducted to evaluate tests for classifying pyrotechnic materials and end items as to their hazard potential are presented. Information required to establish an applicable means of determining the potential hazards of pyrotechnics is described. Hazard evaluations are based on the peak overpressure or impulse resulting from the explosion as a function of distance from the source. Other hazard classification tests include dust ignition sensitivity, impact ignition sensitivity, spark ignition sensitivity, and differential thermal analysis.
Performance evaluation of two black nickel and two black chrome solar collectors
NASA Technical Reports Server (NTRS)
Losey, R.
1977-01-01
The test program was based on the evaluation of four unique solar collectors described below: (1) black nickel collector surface with a desiccant drying bed, (2) black nickel collector surface without a desiccant drying bed, (3) black chrome collector surface with a dessicant drying bed, and (4) black chrome collector surface without a desiccant drying bed. The test program included three distinct phases: Initial performance evaluation, natural environmental aging, and post-aging performance evaluation. Results of Phase III testing conclusively indicated a higher normalized efficiency for Black Chrome surfaces when compared to Black Nickel.
Improvement of information fusion-based audio steganalysis
NASA Astrophysics Data System (ADS)
Kraetzer, Christian; Dittmann, Jana
2010-01-01
In the paper we extend an existing information fusion based audio steganalysis approach by three different kinds of evaluations: The first evaluation addresses the so far neglected evaluations on sensor level fusion. Our results show that this fusion removes content dependability while being capable of achieving similar classification rates (especially for the considered global features) if compared to single classifiers on the three exemplarily tested audio data hiding algorithms. The second evaluation enhances the observations on fusion from considering only segmental features to combinations of segmental and global features, with the result of a reduction of the required computational complexity for testing by about two magnitudes while maintaining the same degree of accuracy. The third evaluation tries to build a basis for estimating the plausibility of the introduced steganalysis approach by measuring the sensibility of the models used in supervised classification of steganographic material against typical signal modification operations like de-noising or 128kBit/s MP3 encoding. Our results show that for some of the tested classifiers the probability of false alarms rises dramatically after such modifications.
Diagnostic Testing and Interpretation of Tests for Autoimmunity
Castro, Christine; Gourley, Mark
2010-01-01
Laboratory testing is of great value when evaluating a patient with a suspected autoimmune disease. The results can confirm a diagnosis, estimate disease severity, aid in assessing prognosis and are useful to follow disease activity. Components of the laboratory exam include complete blood count with differential, comprehensive metabolic panel, inflammatory markers, autoantibodies, and flow cytometry. This chapter discusses these components and includes a discussion about organ-specific immunologic diseases where immunological laboratory testing is employed. Comprehensive laboratory evaluation of a suspected autoimmune illness in conjunction with a thorough clinical evaluation provides a better understanding of a patient's immunologic disease. PMID:20061009
Consequential Validity and the Transformation of Tests from Measurement Tools to Policy Tools
ERIC Educational Resources Information Center
Welner, Kevin G.
2013-01-01
Background/Context: Recent U.S. policy has brought a shift in assessment use, from measurement tools to policy levers. In particular, testing has become a core part of teacher evaluation policies in many states, with test results becoming akin to a job evaluation. Purpose: To explore the notion of consequential validity in assessment use and…
Indoor thermal performance evaluation of the SEPCO air collector
NASA Technical Reports Server (NTRS)
1977-01-01
The procedures used and the results obtained during the evaluation test program on the Solaron solar air collector, model EF-212, under simulated conditions for comparison with data collected in outdoor tests on the same collector are given. The test article was a single glazed collector with a nonsensitive absorber plate, aluminum box frame, and one inch isocyanurate foam insulation.
Comparison of performance criteria for evaluating stake test data
Stan T. Lebow; Patricia K. Lebow; Grant T. Kirker
2017-01-01
Stake tests are a critical part of evaluating durability of wood in ground-contact, but there is a lack of criteria for interpreting stake test results. This paper discusses criteria that might be used to determine if short term ratings indicate satisfactory longterm performance. Ratings of 19 by 19 mm stakes from multiple plots in the Harrison Experimental Forest,...
AM2 Brickwork Pattern Evaluation
2016-12-01
pavement applications. Designation : D 6951. West Consho- hocken, PA: ASTM International. ASTM International. 2010a. Standard test method for in-place... design . This report provides test results for each evaluation and discussions comparing their perfor- mance to previous tests conducted under similar... designated by other authorized documents. DESTRUCTION NOTICE - For classified documents, follow the procedures in DOD5200.22-M, Industrial Security Manual
ERIC Educational Resources Information Center
Belcher, Mary H.; And Others
The third party evaluation of the K-12 career education project RACE (Researched Activities for Career Education) focused on test results of students in four selected grades. A career education questionnaire was administered as a pre-test and again as a post-test to students in the third and sixth grades. Ninth and twelfth grade students were…
DOT National Transportation Integrated Search
2008-02-01
The objective of the proposed research project is to compare the results of two recently introduced nondestructive load test methods to the existing 24-hour load test method described in Chapter 20 of ACI 318-05. The two new methods of nondestructive...
The evaluation of OSTA's APT and ASVT programs
NASA Technical Reports Server (NTRS)
1981-01-01
The results of an evaluation of NASA's Applications Pilot Test (APT) and Applications System Verification and Transfer (AVST) Programs are presented. These programs sponsor cooperative projects between NASA and potential users of remote sensing (primarily LANDSAT) technology from federal and state government and the private sector. Fifteen specific projects, seven APT's and eight ASVT's, are examined as mechanisms for technology development, test, and transfer by comparing their results against stated objectives. Interviews with project managers from NASA field centers and user agency representatives provide the basis for project evaluation from NASA and user perspectives.
Hydrogen-enrichment-concept preliminary evaluation
NASA Technical Reports Server (NTRS)
Ecklund, E. E.
1975-01-01
A hydrogen-enriched fuels concept for automobiles is described and evaluated in terms of fuel consumption and engine exhaust emissions through multicylinder (V-8) automotive engine/hydrogen generator tests, single cylinder research engine (CFR) tests, and hydrogen-generator characterization tests. Analytical predictions are made of the fuel consumption and NO/sub x/ emissions which would result from anticipated engine improvements. The hydrogen-gas generator, which was tested to quantify its thermodynamic input-output relationships was used for integrated testing of the V-8 engine and generator.
Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro
2013-12-01
Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.
Brothman, Arthur R; Dolan, Michelle M; Goodman, Barbara K; Park, Jonathan P; Persons, Diane L; Saxe, Debra F; Tepperberg, James H; Tsuchiya, Karen D; Van Dyke, Daniel L; Wilson, Kathleen S; Wolff, Daynna J; Theil, Karl S
2011-09-01
To evaluate the feasibility of administering a newly established proficiency test offered through the College of American Pathologists and the American College of Medical Genetics for genomic copy number assessment by microarray analysis, and to determine the reproducibility and concordance among laboratory results from this test. Surveys were designed through the Cytogenetic Resource Committee of the two colleges to assess the ability of testing laboratories to process DNA samples provided and interpret results. Supplemental questions were asked with each Survey to determine laboratory practice trends. Twelve DNA specimens, representing 2 pilot and 10 Survey challenges, were distributed to as many as 74 different laboratories, yielding 493 individual responses. The mean consensus for matching result interpretations was 95.7%. Responses to supplemental questions indicate that the number of laboratories offering this testing is increasing, methods for analysis and evaluation are becoming standardized, and array platforms used are increasing in probe density. The College of American Pathologists/American College of Medical Genetics proficiency testing program for copy number assessment by cytogenomic microarray is a successful and efficient mechanism for assessing interlaboratory reproducibility. This will provide laboratories the opportunity to evaluate their performance and assure overall accuracy of patient results. The high level of concordance in laboratory responses across all testing platforms by multiple facilities highlights the robustness of this technology.
Potyrailo, Radislav A; Chisholm, Bret J; Morris, William G; Cawse, James N; Flanagan, William P; Hassib, Lamyaa; Molaison, Chris A; Ezbiansky, Karin; Medford, George; Reitz, Hariklia
2003-01-01
Coupling of combinatorial chemistry methods with high-throughput (HT) performance testing and measurements of resulting properties has provided a powerful set of tools for the 10-fold accelerated discovery of new high-performance coating materials for automotive applications. Our approach replaces labor-intensive steps with automated systems for evaluation of adhesion of 8 x 6 arrays of coating elements that are discretely deposited on a single 9 x 12 cm plastic substrate. Performance of coatings is evaluated with respect to their resistance to adhesion loss, because this parameter is one of the primary considerations in end-use automotive applications. Our HT adhesion evaluation provides previously unavailable capabilities of high speed and reproducibility of testing by using a robotic automation, an expanded range of types of tested coatings by using the coating tagging strategy, and an improved quantitation by using high signal-to-noise automatic imaging. Upon testing, the coatings undergo changes that are impossible to quantitatively predict using existing knowledge. Using our HT methodology, we have developed several coatings leads. These HT screening results for the best coating compositions have been validated on the traditional scales of coating formulation and adhesion loss testing. These validation results have confirmed the superb performance of combinatorially developed coatings over conventional coatings on the traditional scale.
Advanced blade tip seal system, volume 2
NASA Technical Reports Server (NTRS)
Zelahy, J. W.; Fairbanks, N. P.
1982-01-01
The results of the endurance and performance engine tests conducted on monocrystal/abrasive-tipped CF6-50 Stage 1 HPT blades fabricated in Task VII of MATE Project 3 are presented. Two engine tests are conducted. The endurance engine test is conducted for 1000 C cycles. The performance engine test is conducted on a variable cycle core engine. Posttest evaluation and analyses of the blades and shrouds included visual, dimensional, and destructive evaluations.
Shimelis, Techalew; Tadesse, Endale
2015-04-23
To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. A hospital-based cross-sectional study. This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Integrated vehicle-based safety systems : heavy-truck field operational test independent evaluation.
DOT National Transportation Integrated Search
2011-05-01
This report presents results from the independent evaluation of a field operational test using a fleet of heavy trucks outfitted with a prototype integrated crash warning system. This effort was conducted as part of the U.S. DOT?s Integrated Vehicle-...
DOT National Transportation Integrated Search
2000-07-01
This report presents the results of a one-year evaluation test of an Intelligent Transportation Systems (ITS) project known as Advanced Rural Transportation Information and Coordination (ARTIC), located in the Arrowhead Region of Northeastern Minneso...
A comparison between on-site immunoassay drug-testing devices and laboratory results.
Grönholm, M; Lillsunde, P
2001-09-15
The aim with this study was to evaluate the accuracy of several on-site testing devices on the market. A part of this study is included in the European Union's (EU's) roadside testing assessment project (ROSITA). An other request for this kind of study came from the Finnish prison department in the Ministry of Justice. The evaluation was performed on both urine assays and oral fluid assays. The on-site test results were compared with laboratory results (gas chromatography-mass spectrometry (GC/MS)). The samples were tested on amphetamines (AMP), cannabinoids (THC), opiates (OPI) and cocaine metabolites (COC). Some of the tests also included a metamphetamine (MET) and a benzodiazepine (BZO) test. Both positive and negative samples were tested. A total of 800 persons and eight on-site devices for urine and two for oral fluid testing were included in this study. Good results were obtained for the urine on-site devices, with accuracies of 93-99% for amphetamines, 97-99% for cannabinoids, 94-98% for opiates and 90-98% for benzodiazepines. However, differences in the ease of performance and interpretation of test result were observed. It was possible to detect amphetamines and opiates in oral fluid by the used on-site devices, but the benzodiazepines and cannabinoids did not fulfil the needs of sensitivity.
Evaluation of the pathotec Rapid I-D system for identification of Enterobacteriaceae.
Smith, P B; Rhoden, D L; Tomfohrde, K M
1975-01-01
The PathoTec Rapid I-D System for identifying Enterobacteriaceae was evaluated with 471 cultures. In 4,910 individual test comparisons, 95.5% of the results agreed, with results of only two test strips, those for esculin hydrolysis and urease production, agreeing with conventional tests in less than 94% of the trials. The PathoTec system exhibited 94.3% accuracy in identifying these cultures in a double-blind study with conventional media and procedures as the alternate system. Two newly developed test strips, for 0-nitrophenyl-beta-D-galactopyranoside and ornithine decarboxylase, were found to be highly reliable. PMID:1041590
Evaluation and simplification of the occupational slip, trip and fall risk-assessment test
NAKAMURA, Takehiro; OYAMA, Ichiro; FUJINO, Yoshihisa; KUBO, Tatsuhiko; KADOWAKI, Koji; KUNIMOTO, Masamizu; ODOI, Haruka; TABATA, Hidetoshi; MATSUDA, Shinya
2016-01-01
Objective: The purpose of this investigation is to evaluate the efficacy of the occupational slip, trip and fall (STF) risk assessment test developed by the Japan Industrial Safety and Health Association (JISHA). We further intended to simplify the test to improve efficiency. Methods: A previous cohort study was performed using 540 employees aged ≥50 years who took the JISHA’s STF risk assessment test. We conducted multivariate analysis using these previous results as baseline values and answers to questionnaire items or score on physical fitness tests as variables. The screening efficiency of each model was evaluated based on the obtained receiver operating characteristic (ROC) curve. Results: The area under the ROC obtained in multivariate analysis was 0.79 when using all items. Six of the 25 questionnaire items were selected for stepwise analysis, giving an area under the ROC curve of 0.77. Conclusion: Based on the results of follow-up performed one year after the initial examination, we successfully determined the usefulness of the STF risk assessment test. Administering a questionnaire alone is sufficient for screening subjects at risk of STF during the subsequent one-year period. PMID:27021057
Point-of-Care Testing for Anemia, Diabetes, and Hypertension: A Pharmacy-Based Model in Lima, Peru.
Saldarriaga, Enrique M; Vodicka, Elisabeth; La Rosa, Sayda; Valderrama, Maria; Garcia, Patricia J
Prevention and control of chronic diseases is a high priority for many low- and middle-income countries. This study evaluated the feasibility and acceptability of training pharmacy workers to provide point-of-care testing for 3 chronic diseases-hypertension, diabetes, and anemia-to improve disease detection and awareness through private pharmacies. We developed a multiphase training curriculum for pharmacists and pharmacy technicians to build capacity for identification of risk factors, patient education, point-of-care testing, and referral for abnormal results. We conducted a pre-post evaluation with participants and evaluated results using Student t test for proportions. We conducted point-of-care testing with pharmacy clients and evaluated acceptability by patient characteristics (age, gender, and type of patient) using multiple logistic regression. In total, 72 pharmacy workers (66%) completed the full training curriculum. Pretest scores indicated that pharmacists had more knowledge and skills in chronic disease risk factors, patient education, and testing than pharmacy technicians. All participants improved their knowledge and skills after the training, and post-test scores indicated that pharmacy technicians achieved the same level of competency as pharmacists (P < .01). Additionally, 698 clients received at least 1 test during the study; 53% completed the acceptability survey. Nearly 100% thought the pharmacy could provide faster results, faster and better attention, and better access to basic screening for hypertension, diabetes, and anemia than a traditional health center. Fast service was very important: 41% ranked faster results and 30% ranked faster attention as the most important factor for receiving diagnostic testing in the pharmacy. We found that it is both feasible for pharmacies and acceptable to clients to train pharmacy workers to provide point-of-care testing for anemia, diabetes, and hypertension. This innovative approach holds potential to increase early detection of risk factors and bolster disease prevention and management efforts in Peru and other low- and middle-income settings. Copyright © 2017. Published by Elsevier Inc.
Fault detection and accommodation testing on an F100 engine in an F-15 airplane
NASA Technical Reports Server (NTRS)
Myers, L. P.; Baer-Riedhart, J. L.; Maxwell, M. D.
1985-01-01
The fault detection and accommodation (FDA) methodology for digital engine-control systems may range from simple comparisons of redundant parameters to the more complex and sophisticated observer models of the entire engine system. Evaluations of the various FDA schemes are done using analytical methods, simulation, and limited-altitude-facility testing. Flight testing of the FDA logic has been minimal because of the difficulty of inducing realistic faults in flight. A flight program was conducted to evaluate the fault detection and accommodation capability of a digital electronic engine control in an F-15 aircraft. The objective of the flight program was to induce selected faults and evaluate the resulting actions of the digital engine controller. Comparisons were made between the flight results and predictions. Several anomalies were found in flight and during the ground test. Simulation results showed that the inducement of dual pressure failures was not feasible since the FDA logic was not designed to accommodate these types of failures.
QM-8 final performance evaluation report: SEALS, volume 4
NASA Technical Reports Server (NTRS)
Nelsen, L. V.
1989-01-01
The Space Shuttle Redesigned Solid Rocket Motor (RSRM) static test of Qualification Motor-8 (QM-8) was conducted. The QM-8 test article was the fifth full-scale, full-duration test, and the third qualification motor to incorporate the redesigned case field joint and nozzle-to-case joint. This was the second static test conducted in the T-97 test facility, which is equipped with actuators for inducing external side loads to a 360 degree external tank (ET) attach ring during test motor operation, and permits heating/cooling of an entire motor. The QM-8 motor was cooled to a temperature which ensured that the maximum propellant mean bulk temperature (PMBT) of 40 F was achieved at firing. All test results are not included, but rather, the performance of the metal case, field joints, and nozzle-to-case joint is addressed. The involvement is studied of the Structural Applications and Structural Design Groups with the QM-8 test which includes: assembly procedures of the field and nozzle-to-case joints, joint leak check results, structural test results, and post-test inspection evaluations.
On-orbit evaluation of the control system/structural mode interactions on OSO-8
NASA Technical Reports Server (NTRS)
Slafer, L. I.
1980-01-01
The Orbiting Solar Observatory-8 experienced severe structural mode/control loop interaction problems during the spacecraft development. Extensive analytical studies, using the hybrid coordinate modeling approach, and comprehensive ground testing were carried out in order to achieve the system's precision pointing performance requirements. A recent series of flight tests were conducted with the spacecraft in which a wide bandwidth, high resolution telemetry system was utilized to evaluate the on-orbit flexible dynamics characteristics of the vehicle along with the control system performance. This paper describes the results of these tests, reviewing the basic design problem, analytical approach taken, ground test philosophy, and on-orbit testing. Data from the tests was used to determine the primary mode frequency, damping, and servo coupling dynamics for the on-orbit condition. Additionally, the test results have verified analytically predicted differences between the on-orbit and ground test environments. The test results have led to a validation of both the analytical modeling and servo design techniques used during the development of the control system, and also verified the approach taken to vehicle and servo ground testing.
Advanced Guidance and Control Methods for Reusable Launch Vehicles: Test Results
NASA Technical Reports Server (NTRS)
Hanson, John M.; Jones, Robert E.; Krupp, Don R.; Fogle, Frank R. (Technical Monitor)
2002-01-01
There are a number of approaches to advanced guidance and control (AG&C) that have the potential for achieving the goals of significantly increasing reusable launch vehicle (RLV) safety/reliability and reducing the cost. In this paper, we examine some of these methods and compare the results. We briefly introduce the various methods under test, list the test cases used to demonstrate that the desired results are achieved, show an automated test scoring method that greatly reduces the evaluation effort required, and display results of the tests. Results are shown for the algorithms that have entered testing so far.
Diercks, Deborah B; Kirk, J Douglas; Turnipseed, Samuel D; Amsterdam, Ezra A
2007-12-01
Risk of acute coronary events in patients with methamphetamine and cocaine intoxication has been described. Little is known about the need for additional evaluation in these patients who do not have evidence of myocardial infarction after the initial emergency department evaluation. We herein describe our experience with these patients in a chest pain unit (CPU) and the rate of cardiac-related chest pain in this group. Retrospective analysis of patients evaluated in our CPU from January 1, 2000 to December 16, 2004 with a history of chest pain. Patients who had a positive urine toxicologic screen for methamphetamine or cocaine were included. No patients had ECG or cardiac injury marker evidence of myocardial infarction or ischemia during the initial emergency department evaluation. A diagnosis of cardiac-related chest pain was based upon positive diagnostic testing (exercise stress testing, nuclear perfusion imaging, stress echocardiography, or coronary artery stenosis >70%). During the study period, 4568 patients were evaluated in the CPU. A total of 1690 (37%) of patients admitted to the CPU underwent urine toxicologic testing. The result of urine toxicologic test was positive for cocaine or methamphetamine in 224 (5%). In the 2871 patients who underwent diagnostic testing for coronary artery disease (CAD), 401 (14%) were found to have positive results. There was no difference in the prevalence of CAD between those with positive result for toxicology screens (26/156, 17%) and those without (375/2715, 13%, RR 1.2, 95% CI 0.8-1.7). These findings suggest a relatively high rate of CAD in patients with methamphetamine and cocaine use evaluated in a CPU.
Festi, D.; Capodicasa, S.; Sandri, L.; Colaiocco-Ferrante, L.; Staniscia, T.; Vitacolonna, E.; Vestito, A.; Simoni, P.; Mazzella, G.; Portincasa, P.; Roda, E.; Colecchia, A.
2005-01-01
AIM: To evaluate and compare the clinical usefulness of 13C-phenylalanine and 13C-methacetin breath tests in quantitating functional hepatic mass in patients with chronic liver disease and to further compare these results with those of conventional tests, Child-Pugh score and serum bile acid levels. METHODS: One hundred and forty patients (50 HCV- related chronic hepatitis, 90 liver cirrhosis patients) and 40 matched healthy controls were studied. Both breath test and routine liver test, serum levels of cholic and chenodeoxycholic acid conjugates were evaluated. RESULTS: Methacetin breath test, expressed as 60 min cumulative percent of oxidation, discriminated the hepatic functional capacity not only between controls and liver disease patients, but also between different categories of chronic liver disease patients. Methacetin breath test was correlated with liver function tests and serum bile acids. Furthermore, methacetin breath test, as well as serum bile acids, were highly predictive of Child-Pugh scores. The diagnostic power of phenylalanine breath test was always less than that of methacetin breath test. CONCLUSION: Methacetin breath test represents a safe and accurate diagnostic tool in the evaluation of hepatic functional mass in chronic liver disease patients. PMID:15609414
Flexible Transcription Testing
ERIC Educational Resources Information Center
Carr-Smith, Norma
1976-01-01
Flexible structure in a San Francisco State University shorthand course is described as a way to provide motivation for students. Topics discussed are transcription testing plan, method of evaluation, practice tests, increasing difficulty of tests, and classroom results. (TA)
Gonzalez-Neira, Eliana Maria; Jimenez-Mendoza, Claudia Patricia; Suarez, Daniel R; Rugeles-Quintero, Saul
2016-03-30
This study aims at determining if a collection of 16 motor tests on a physical simulator can objectively discriminate and evaluate practitioners' competency level, i.e. novice, resident, and expert. An experimental design with three study groups (novice, resident, and expert) was developed to test the evaluation power of each of the 16 simple tests. An ANOVA and a Student Newman-Keuls (SNK) test were used to analyze results of each test to determine which of them can discriminate participants' competency level. Four of the 16 tests used discriminated all of the three competency levels and 15 discriminated at least two of the three groups (α= 0.05). Moreover, other two tests differentiate beginners' level from intermediate, and other seven tests differentiate intermediate level from expert. The competency level of a practitioner of minimally invasive surgery can be evaluated by a specific collection of basic tests in a physical surgical simulator. Reduction of the number of tests needed to discriminate the competency level of surgeons can be the aim of future research.
NASA Astrophysics Data System (ADS)
Albertson, C. W.
1982-03-01
A 1/12th scale model of the Curved Surface Test Apparatus (CSTA), which will be used to study aerothermal loads and evaluate Thermal Protection Systems (TPS) on a fuselage-type configuration in the Langley 8-Foot High Temperature Structures Tunnel (8 ft HTST), was tested in the Langley 7-Inch Mach 7 Pilot Tunnel. The purpose of the tests was to study the overall flow characteristics and define an envelope for testing the CSTA in the 8 ft HTST. Wings were tested on the scaled CSTA model to select a wing configuration with the most favorable characteristics for conducting TPS evaluations for curved and intersecting surfaces. The results indicate that the CSTA and selected wing configuration can be tested at angles of attack up to 15.5 and 10.5 degrees, respectively. The base pressure for both models was at the expected low level for most test conditions. Results generally indicate that the CSTA and wing configuration will provide a useful test bed for aerothermal pads and thermal structural concept evaluation over a broad range of flow conditions in the 8 ft HTST.
NASA Technical Reports Server (NTRS)
Albertson, C. W.
1982-01-01
A 1/12th scale model of the Curved Surface Test Apparatus (CSTA), which will be used to study aerothermal loads and evaluate Thermal Protection Systems (TPS) on a fuselage-type configuration in the Langley 8-Foot High Temperature Structures Tunnel (8 ft HTST), was tested in the Langley 7-Inch Mach 7 Pilot Tunnel. The purpose of the tests was to study the overall flow characteristics and define an envelope for testing the CSTA in the 8 ft HTST. Wings were tested on the scaled CSTA model to select a wing configuration with the most favorable characteristics for conducting TPS evaluations for curved and intersecting surfaces. The results indicate that the CSTA and selected wing configuration can be tested at angles of attack up to 15.5 and 10.5 degrees, respectively. The base pressure for both models was at the expected low level for most test conditions. Results generally indicate that the CSTA and wing configuration will provide a useful test bed for aerothermal pads and thermal structural concept evaluation over a broad range of flow conditions in the 8 ft HTST.
Cox, Linda; Williams, Brock; Sicherer, Scott; Oppenheimer, John; Sher, Larry; Hamilton, Robert; Golden, David
2008-12-01
The intended purpose of this monograph is to provide a general overview of allergy diagnostics for health care professionals who care for patients with allergic disease. For a more comprehensive review of allergy diagnostic testing, readers can refer to the Allergy Diagnostic Practice Parameters. A key message is that a positive allergy test result (skin or blood) indicates only the presence of allergen specific IgE (called sensitization). It does not necessarily mean clinical allergy (ie, allergic symptoms with exposure). It is important for this reason that the allergy evaluation be based on the patient's history and directed by a health care professional with sufficient understanding of allergy diagnostic testing to use the information obtained from his/her evaluation of the patient to determine (1) what allergy diagnostic tests to order, (2) how to interpret the allergy diagnostic test results, and (3) how to use the information obtained from the allergy evaluation to develop an appropriate therapeutic treatment plan.
NASA Astrophysics Data System (ADS)
Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.; Recknagle, Kurtis P.; Flaherty, Julia E.; Antonio, Ernest J.; Glissmeyer, John A.
2018-03-01
The ANSI/HPS N13.1-2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N2O) was evaluated as a potential replacement to SF6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position, and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF6 modeling corroborated N2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N2O testing to SF6 testing in the context of stack qualification tests. The results demonstrate that N2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.
Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia
Aralica, Merica; Krleza, Jasna Lenicek
2017-01-01
Introduction Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. Materials and methods EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Results Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Conclusion Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level. PMID:28392735
Progress on Component Evaluation for Nuclear Explosion Monitoring
2008-09-01
one data logger, Geotech Smart24. For the infrasound sensors tested, the test results allow us to conclude that both sensors had sufficiently quiet...a lower frequency than expected. Sandia was also asked to evaluate the Geotech Smart24 data logger for qualification as a replacement to the Geotech ...results of using 26-bit quantization. Characterization Geotech Smart24 Data-Logger with Active Fortezza Crypto Card Data Signing Over the spring
[The MMPI-2 test in the evaluation of the mobbing syndrome].
Pappone, P; Santalucia, L; Del Castello, E; De Maino, V; Garofalo, E; Cappelluccio, R; Feola, D; Ruberto, M; Liotti, F
2007-01-01
MMPI-2 test is widely used in psychodiagnostic evaluation as well as in the evaluation of psychic pathologies related to psychosocial adversative events in working activities. A more efficacious use of MMPI-2 test in the working context can be achieved by the individuation of indexes able to facilitate the evaluation of mobbing syndrome. This work is based on the analysis of 150 cases (39.7% women and 60.7% men, 30 to 60 years of age), evaluated through an accurate examination of working history and a series of clinic conversations, followed by psychodiagnostic evaluation. The average of T-scores on the clinical scale, the content scale, the PK addition scale and the validation scale were calculated from tests. Pathologic high T-scores on the scales Hs, D. Hy e Pa were found in subjects having positive mobbing anamnesis. These results strongly indicate the presence of clinical specificities in workers exposed to working harassments, and that these specificities can be efficaciously evidenced by the MMPI-2 test.
Boverhof, Darrell R; Wiescinski, Connie M; Botham, Phil; Lees, David; Debruyne, Eric; Repetto-Larsay, Marina; Ladics, Gregory; Hoban, Denise; Gamer, Armin; Remmele, Marina; Wang-Fan, Weizheng; Ullmann, Ludwig G; Mehta, Jyotigna; Billington, Richard; Woolhiser, Michael R
2008-09-01
The mouse local lymph node assay (LLNA) has become the preferred test for evaluating the dermal sensitization potential of chemicals and requirements are now emerging for its use in the evaluation of their formulated products, especially in the European Union. However, despite its widespread use and extensive validation, the use of this assay for directly testing mixtures and formulated products has been questioned, which could lead to repeat testing using multiple animal models. As pesticide formulations are typically a specific complex blend of chemicals for use as aqueous-based dilutions, traditional vehicles prescribed for the LLNA may change the properties of these formulations leading to inaccurate test results and hazard identification. The objective of this study was to evaluate the effectiveness of an aqueous solution of Pluronic L92 block copolymer surfactant (L92) as a vehicle in the mouse LLNA across five laboratories. Three chemicals with known sensitization potential and four pesticide formulations for which the sensitization potential in guinea pigs and/or humans had previously been assessed were used. Identical LLNA protocols and test materials were used in the evaluation. Assessment of the positive control chemicals, hexylcinnamaldehyde, formaldehyde, and potassium dichromate revealed positive results when using 1% aqueous L92 as the vehicle. Furthermore, results for these chemicals were reproducible among the five laboratories and demonstrated consistent relative potency determinations. The four pesticide formulations diluted in 1% aqueous L92 also demonstrated reproducible results in the LLNA among the five laboratories. Results for these test materials were also consistent with those generated previously using guinea pigs or from human experience. These data support testing aqueous compatible chemicals or pesticide formulations using the mouse LLNA, and provide additional support for the use of 1% aqueous L92 as a suitable, aqueous-based vehicle.
Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S
2015-01-01
Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.
2018-01-01
ABSTRACT We describe results from a multicenter study evaluating the Accelerate Pheno system, a first of its kind diagnostic system that rapidly identifies common bloodstream pathogens from positive blood cultures within 90 min and determines bacterial phenotypic antimicrobial susceptibility testing (AST) results within ∼7 h. A combination of fresh clinical and seeded blood cultures were tested, and results from the Accelerate Pheno system were compared to Vitek 2 results for identification (ID) and broth microdilution or disk diffusion for AST. The Accelerate Pheno system accurately identified 14 common bacterial pathogens and two Candida spp. with sensitivities ranging from 94.6 to 100%. Of fresh positive blood cultures, 89% received a monomicrobial call with a positive predictive value of 97.3%. Six common Gram-positive cocci were evaluated for ID. Five were tested against eight antibiotics, two resistance phenotypes (methicillin-resistant Staphylococcus aureus and Staphylococcus spp. [MRSA/MRS]), and inducible clindamycin resistance (MLSb). From the 4,142 AST results, the overall essential agreement (EA) and categorical agreement (CA) were 97.6% and 97.9%, respectively. Overall very major error (VME), major error (ME), and minor error (mE) rates were 1.0%, 0.7%, and 1.3%, respectively. Eight species of Gram-negative rods were evaluated against 15 antibiotics. From the 6,331 AST results, overall EA and CA were 95.4% and 94.3%, respectively. Overall VME, ME, and mE rates were 0.5%, 0.9%, and 4.8%, respectively. The Accelerate Pheno system has the unique ability to identify and provide phenotypic MIC and categorical AST results in a few hours directly from positive blood culture bottles and support accurate antimicrobial adjustment. PMID:29305546
Strom, Suzanne L; Anderson, Craig L; Yang, Luanna; Canales, Cecilia; Amin, Alpesh; Lotfipour, Shahram; McCoy, C Eric; Osborn, Megan Boysen; Langdorf, Mark I
2015-11-01
Traditional Advanced Cardiac Life Support (ACLS) courses are evaluated using written multiple-choice tests. High-fidelity simulation is a widely used adjunct to didactic content, and has been used in many specialties as a training resource as well as an evaluative tool. There are no data to our knowledge that compare simulation examination scores with written test scores for ACLS courses. To compare and correlate a novel high-fidelity simulation-based evaluation with traditional written testing for senior medical students in an ACLS course. We performed a prospective cohort study to determine the correlation between simulation-based evaluation and traditional written testing in a medical school simulation center. Students were tested on a standard acute coronary syndrome/ventricular fibrillation cardiac arrest scenario. Our primary outcome measure was correlation of exam results for 19 volunteer fourth-year medical students after a 32-hour ACLS-based Resuscitation Boot Camp course. Our secondary outcome was comparison of simulation-based vs. written outcome scores. The composite average score on the written evaluation was substantially higher (93.6%) than the simulation performance score (81.3%, absolute difference 12.3%, 95% CI [10.6-14.0%], p<0.00005). We found a statistically significant moderate correlation between simulation scenario test performance and traditional written testing (Pearson r=0.48, p=0.04), validating the new evaluation method. Simulation-based ACLS evaluation methods correlate with traditional written testing and demonstrate resuscitation knowledge and skills. Simulation may be a more discriminating and challenging testing method, as students scored higher on written evaluation methods compared to simulation.
The use of one- versus two-tailed tests to evaluate prevention programs.
Ringwalt, Chris; Paschall, M J; Gorman, Dennis; Derzon, James; Kinlaw, Alan
2011-06-01
Investigators have used both one- and two-tailed tests to determine the significance of findings yielded by program evaluations. While the literature that addresses the appropriate use of each type of significance test should be used is historically inconsistent, almost all authorities now agree that one-tailed tests are rarely (if ever) appropriate. A review of 85 published evaluations of school-based drug prevention curricula specified on the National Registry of Effective Programs and Practices revealed that 20% employed one-tailed tests and, within this subgroup, an additional 4% also employed two-tailed tests. The majority of publications either did not specify the type of statistical test employed or used some other criterion such as effect sizes or confidence intervals. Evaluators reported that they used one-tailed tests either because they stipulated the direction of expected findings in advance, or because prior evaluations of similar programs had yielded no negative results. The authors conclude that one-tailed tests should never be used because they introduce greater potential for Type I errors and create an uneven playing field when outcomes are compared across programs. The authors also conclude that the traditional threshold of significance that places α at .05 is arbitrary and obsolete, and that evaluators should consistently report the exact p values they find.
Thermal performance of MSFC hot air collectors under natural and simulated conditions
NASA Technical Reports Server (NTRS)
Shih, K., Sr.
1977-01-01
The procedures used and the results obtained from an evaluation test program conducted to determine the thermal performance and structural characteristics of selected MSFC--designed hot air collectors under both real and simulated environmental conditions are described. Five collectors were tested in the three phased program. A series of outdoor tests were conducted to determine stagnation temperatures on a typical bright day and to determine each collector's ability to withstand these temperatures. Two of the collectors experienced structural deformation sufficient to eliminate them from the remainder of the test program. A series of outdoor tests to evaluate the thermal performance of collector S/N 10 under certain test conditions were performed followed by a series of indoor tests to evaluate the thermal performance of the collector under closely controlled simulated conditions.
Investigation of optimized graded concrete for Oklahoma.
DOT National Transportation Integrated Search
2013-07-01
This report presents the results of several novel test methods to investigate concrete for slip formed paving. These tests include the Box Test, a novel test to evaluate the response of concrete to vibration, the AIMS2, an automated test for aggregat...
COTS Ceramic Chip Capacitors: An Evaluation of the Parts and Assurance Methodologies
NASA Technical Reports Server (NTRS)
Brusse, Jay A.; Sampson, Michael J.
2004-01-01
Commercial-Off-The-Shelf (COTS) multilayer ceramic chip capacitors (MLCCs) are continually evolving to reduce physical size and increase volumetric efficiency. Designers of high reliability aerospace and military systems are attracted to these attributes of COTS MLCCs and would like to take advantage of them while maintaining the high standards for long-term reliable operation they are accustomed io when selecting military qualified established reliability (MIL-ER) MLCCs. However, MIL-ER MLCCs are not available in the full range of small chip sizes with high capacitance as found in today's COTS MLCCs. The objectives for this evaluation were to assess the long-term performance of small case size COTS MLCCs and to identify effective, lower-cost product assurance methodologies. Fifteen (15) lots of COTS X7R dielectric MLCCs from four (4) different manufacturers and two (2) MIL-ER BX dielectric MLCCs from two (2) of the same manufacturers were evaluated. Both 0805 and 0402 chip sizes were included. Several voltage ratings were tested ranging from a high of 50 volts to a low of 6.3 volts. The evaluation consisted of a comprehensive screening and qualification test program based upon MIL-PRF-55681 (i.e., voltage conditioning, thermal shock, moisture resistance, 2000-hour life test, etc.). In addition, several lot characterization tests were performed including Destructive Physical Analysis (DPA), Highly Accelerated Life Test (HALT) and Dielectric Voltage Breakdown Strength. The data analysis included a comparison of the 2000-hour life test results (used as a metric for long-term performance) relative to the screening and characterization test results. Results of this analysis indicate that the long-term life performance of COTS MLCCs is variable -- some lots perform well, some lots perform poorly. DPA and HALT were found to be promising lot characterization tests to identify substandard COTS MLCC lots prior to conducting more expensive screening and qualification tests. The results indicate that lot- specific screening and qualification are still recommended for high reliability applications. One significant and concerning observation is that MIL- type voltage conditioning (100 hours at twice rated voltage, 125 C) was not an effective screen in removing infant mortality parts for the particular lots of COTS MLCCs evaluated.
DOT National Transportation Integrated Search
2011-07-01
This report documents the results of the independent evaluations assessment of the driver acceptance of the Cooperative Intersection Collision Avoidance System limited to Stop Sign and Traffic Signal Violations (CICAS-V) system as tested during a ...
Evaluation of Criteria Associated with Abdominal Fitness Testing.
ERIC Educational Resources Information Center
Robertson, Loarn D.; Magnusdottir, Hjordis
1987-01-01
The use of the timed sit up as a measure of abdominal fitness has been challenged. This article describes experiments designed to evaluate a modified curl up test as an alternative. Subjects were 20 college students averaging 25.3 years of age. Results are discussed. (Author/MT)
Dewatering Treatment Scale-up Testing Results of Hanford Tank Wastes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tedeschi, A.R.; May, T.H.; Bryan, W.E.
2008-07-01
This report documents CH2M HILL Hanford Group Inc. (CH2M HILL) 2007 dryer testing results in Richland, WA at the AMEC Nuclear Ltd., GeoMelt Division (AMEC) Horn Rapids Test Site. It provides a discussion of scope and results to qualify the dryer system as a viable unit-operation in the continuing evaluation of the bulk vitrification process. A 10,000 liter (L) dryer/mixer was tested for supplemental treatment of Hanford tank low activity wastes, drying and mixing a simulated non-radioactive salt solution with glass forming minerals. Testing validated the full scale equipment for producing dried product similar to smaller scale tests, and qualifiedmore » the dryer system for a subsequent integrated dryer/vitrification test using the same simulant and glass formers. The dryer system is planned for installation at the Hanford tank farms to dry/mix radioactive waste for final treatment evaluation of the supplemental bulk vitrification process. (authors)« less
Boehm, D M; Bernhardt, M; Kurzynski, T A; Pennell, D R; Schell, R F
1990-01-01
Two commercial tests for the rapid identification of Neisseria gonorrhoeae were evaluated. Two hundred seventy-nine organisms were tested, including 202 strains of N. gonorrhoeae. The Syva MicroTrak test results were less subjective but required a fluorescence microscope. The Phadebact Monoclonal GC OMNI Test required modification of the manufacturer's interpretive instructions in order to avoid cross-reactions, but it was a practical test. Specificities of both tests were 100%. Sensitivities of the Phadebact Monoclonal GC OMNI and Syva MicroTrak tests were 100% and approximately 100%, respectively. PMID:2121792
2014-01-01
Background In this article, the test implementation of a school-oriented drug prevention program “Study without Drugs” is discussed. The aims of this study were to determine the results of the process evaluation and to determine whether the proposed school-oriented drug prevention program during a pilot project was effective for the participating pupils. Methods Sixty second-grade pupils at a junior high school in Paramaribo, Suriname participated in the test implementation. They were divided into two classes. For the process evaluation the students completed a structured questionnaire focusing on content and teaching method after every lesson. Lessons were qualified with a score from 0–10. The process was also evaluated by the teachers through structured interviews. Attention was paid to reach, dose delivered, dose received, fidelity, connection, achieved effects/observed behaviors, areas for improvement, and lesson strengths. The effect evaluation was conducted by using the General Liniair Model (repeated measure). The research (-design) was a pre-experimental design with pre-and post-test. Results No class or sex differences were detected among the pupils with regard to the assessment of content, methodology, and qualification of the lessons. Post-testing showed that participating pupils obtained an increased knowledge of drugs, their drug-resisting skills were enhanced, and behavior determinants (attitude, subjective norm, self-efficacy, and intention) became more negative towards drugs. Conclusions From the results of the test implementation can be cautiously concluded that the program “Study without Drugs” may yield positive results when applied in schools). Thus, this pilot program can be considered a step towards the development and implementation of an evidence-based school-oriented program for pupils in Suriname. PMID:24920468
NASA Astrophysics Data System (ADS)
Brodic, D.
2011-01-01
Text line segmentation represents the key element in the optical character recognition process. Hence, testing of text line segmentation algorithms has substantial relevance. All previously proposed testing methods deal mainly with text database as a template. They are used for testing as well as for the evaluation of the text segmentation algorithm. In this manuscript, methodology for the evaluation of the algorithm for text segmentation based on extended binary classification is proposed. It is established on the various multiline text samples linked with text segmentation. Their results are distributed according to binary classification. Final result is obtained by comparative analysis of cross linked data. At the end, its suitability for different types of scripts represents its main advantage.
Pharmacodynamics of Promethazine in Human Subjects
NASA Technical Reports Server (NTRS)
Gatlin, K. T.; Boyd, J. L.; Wang, Z.; Das, H.; Putcha, L.
2005-01-01
Promethazine (PMZ) is the drug of choice for the treatment of symptoms associated with space motion sickness in astronauts. Side effects of PMZ include sedation, dizziness and cognitive performance impairment. In this study, we examined pharmacodynamics (PD) in human subjects and validated methods for evaluating cognitive performance effects of medications in space. METHODS: PMZ (12.5,25, and 50 mg) or placebo was administered by IM injection to human subjects in a randomized double-blind treatment design. Samples and data were collected for 72 h post dose. PD evaluation was performed using a battery of performance tests administered using WinSCAT (Windows based Space Cognitive Assessment Test) on a laptop computer, and ARES (ANAM Readiness Evaluation System) on a PDA, plasma concentrations of PMZ were measured using a LC-MS method. RESULTS: Results indicate a linear correlation between PMZ concentration and cognitive performance parameters (p<0.01). Test accuracy decreased and test completion time and response time increased significantly with increasing plasma PMZ concentration. CONCLUSIONS: These results suggest a concentration dependent decrement in cognitive performance associated with PMZ. WinSCAT and ARES are sensitive tools for the assessment PMZ PD and may be applicable for such evaluations with other neurocognitive drugs.
Constant Head Evaluation of Full Scale Soil Absorption Fields
NASA Astrophysics Data System (ADS)
Dix, S. P.
2001-05-01
Design loading rates for septic tank effluent in trenches of various designs with different geometry and media has been debated for decades. The role of bottom and sidewall is a hot topic with many opinion by experts in the field of agricultural and environmental engineering. Research institutions have conducted numerous studies and developed procedures for measuring both test systems and fundamental of soil hydraulics. Falling head tests have been used more recently to evaluate mature test cells and evaluate both sidewall and basal absorption, (Keys et al). The proposed paper will discuss the design and testing of a constant head permeameter. Testing this equipment and developing the test protocol followed the application of the procedure to on a number of residential systems in both sandy and clay loam soil. Results from this testing showed the relability step that must be taken to successfully use this equipment. Result of the testing show the variability and consistency of absorption, the changes in absorption when systems are flooded above their equilibrium condition and the longer-term changes that occur when trenches are rested in a warm climate. More recent application of the test procedure evaluated affects of head and increased depth sidewall on absorption rates when the effluent level in the trenches was raised. Future modification of the test equipment and procedure by integrating a data logger will permits more exact recording of dose cycles and improved estimate of soil absorption efficiency over time.
Huang, Wenhao; Chapman-Novakofski, Karen M
2017-01-01
Background The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. Objective The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps’ educational quality and technical functionality. Methods Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Results Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no significant change over time (P>.05) for all but skill development (P=.001). Construct reliability was good for items assessing age appropriateness of apps for children, teens, and a general audience. In addition, construct reliability was acceptable for assessing app appropriateness for various target audiences (Cronbach alpha >.70). For the 5 main factors, ICC (1,k) was >.80, with a P value of <.05. When 15 nutrition professionals evaluated one app, ICC (2,15) was .98, with a P value of <.001 for all 7 constructs when the modifiable items were specified for adults seeking weight loss support. Conclusions Our preliminary effort shows that AQEL is a valid, reliable instrument for evaluating nutrition apps’ qualities for clinical interventions by nutrition clinicians, educators, and researchers. Further efforts in validating AQEL in various contexts are needed. PMID:29079554
[Research progress on mechanical performance evaluation of artificial intervertebral disc].
Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang
2018-03-01
The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.
Serving the Needs of Various Groups of Stakeholders.
ERIC Educational Resources Information Center
Geva-May, Iris; Peretz, Hannah
1991-01-01
The extent to which evaluation results answer different stakeholders' needs was explored in the evaluation of a business English course at Van Leer Institute for the Development of Executive Assistants in Tel-Aviv (Israel), using diagnostic tests. Students (n=52), teachers, curriculum team, and administrators could use the evaluation results. (SLD)
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1975-01-01
Several groups of nickel cadmium cells were tested for the durability of their separator materials. The cells were rated at 6.0 ampere-hours, and contained double ceramic seals. Two cells in each group were fitted with pressure gauge assemblies. Results are presented for various brands of separator materials.
NASA Technical Reports Server (NTRS)
Lummus, J. R.; Joyce, G. T.; Omalley, C. D.
1980-01-01
An evaluation of current prediction methodologies to estimate the aerodynamic uncertainties identified for the E205 configuration is presented. This evaluation was accomplished by comparing predicted and wind tunnel test data in three major categories: untrimmed longitudinal aerodynamics; trimmed longitudinal aerodynamics; and lateral-directional aerodynamic characteristics.
Technology Transferred to the Kirby Company
NASA Technical Reports Server (NTRS)
1996-01-01
NASA Lewis Research Center's Propulsion Systems Branch, evaluated the structural and vibration characteristics of the Kirby Model G-4 fan. Modes of vibration and resonance potential were evaluated in the Holography Test Lab at Lewis. As a result of the Lewis tests and rotor structural evaluation, Kirby engineers gained new insights into their existing design, enabling them to develop a more robust fan for use in their vacuum cleaners.
Evaluation of roll designs on a roll-crusher/ crusher/splitter biomass harvester: test bench results
Colin Ashmore; Donald L. Sirois; Bryce J. Stokes
1987-01-01
Four different roll designs were evaluated on a test bench roll crusher/splitter to determine feeding and crushing efficiencies. For each design, different gap settings for the primary and secondary rolls were tested at two hydraulic cylinder pressures on the primary crush roll to determine their ability to crush and/or feed tree bolts. Seven different diameter classes...
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1975-01-01
Quality control measures for Ni-Cd spacecraft cells were analyzed. Cells were examined for electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.50 volts during the internal short test. Test results are given in tabular form.
NASA Astrophysics Data System (ADS)
Strohmeier, Dominik; Kunze, Kristina; Göbel, Klemens; Liebetrau, Judith
2013-01-01
Assessing audiovisual Quality of Experience (QoE) is a key element to ensure quality acceptance of today's multimedia products. The use of descriptive evaluation methods allows evaluating QoE preferences and the underlying QoE features jointly. From our previous evaluations on QoE for mobile 3D video we found that mainly one dimension, video quality, dominates the descriptive models. Large variations of the visual video quality in the tests may be the reason for these findings. A new study was conducted to investigate whether test sets of low QoE are described differently than those of high audiovisual QoE. Reanalysis of previous data sets seems to confirm this hypothesis. Our new study consists of a pre-test and a main test, using the Descriptive Sorted Napping method. Data sets of good-only and bad-only video quality were evaluated separately. The results show that the perception of bad QoE is mainly determined one-dimensionally by visual artifacts, whereas the perception of good quality shows multiple dimensions. Here, mainly semantic-related features of the content and affective descriptors are used by the naïve test participants. The results show that, with increasing QoE of audiovisual systems, content semantics and users' a_ective involvement will become important for assessing QoE differences.
Evaluation of Stress Corrosion Resistance Properties of 15CrMoR(H) in H2S Environment
NASA Astrophysics Data System (ADS)
Zhang, Yiliang; Wang, Jing; Wu, Mingyao; Li, Shurui; Liu, Wenbin
To evaluate the hydrogen resistant properties of the 15CrMoR(H) with new smelting process, according to NACE and National Standards, three tests including NACE standard tensile test, NACE standard bent-beam test and hydrogen induced cracking test are executed in saturated hydrogen sulfide(H2S) environment. Stress-life mathematical model of this material is given by analyzing and fitting the results of tensile test. Test results show that the threshold sth of tensile test is 0.7R eL(252MPa); the threshold nominal stress SC of bent-beam is higher than 4.5 R eL (1620MPa); for HIC test, the crack length rate CLR is 4.40%, the crack thickness rate CTR is 0.87% and the crack sensitive rate CSR is 0.04%. Compare with EFC standard, the safety margin of HIC test is 3.4, 3.4 and 37.5 times respectively. All the experimental results show that the new 15CrMoR(H) material has excellent H2S environmental cracking resistance properties.
Computer Administering of the Psychological Investigations: Set-Relational Representation
NASA Astrophysics Data System (ADS)
Yordzhev, Krasimir
Computer administering of a psychological investigation is the computer representation of the entire procedure of psychological assessments - test construction, test implementation, results evaluation, storage and maintenance of the developed database, its statistical processing, analysis and interpretation. A mathematical description of psychological assessment with the aid of personality tests is discussed in this article. The set theory and the relational algebra are used in this description. A relational model of data, needed to design a computer system for automation of certain psychological assessments is given. Some finite sets and relation on them, which are necessary for creating a personality psychological test, are described. The described model could be used to develop real software for computer administering of any psychological test and there is full automation of the whole process: test construction, test implementation, result evaluation, storage of the developed database, statistical implementation, analysis and interpretation. A software project for computer administering personality psychological tests is suggested.
Shuttle payload minimum cost vibroacoustic tests
NASA Technical Reports Server (NTRS)
Stahle, C. V.; Gongloff, H. R.; Young, J. P.; Keegan, W. B.
1977-01-01
This paper is directed toward the development of the methodology needed to evaluate cost effective vibroacoustic test plans for Shuttle Spacelab payloads. Statistical decision theory is used to quantitatively evaluate seven alternate test plans by deriving optimum test levels and the expected cost for each multiple mission payload considered. The results indicate that minimum costs can vary by as much as $6 million for the various test plans. The lowest cost approach eliminates component testing and maintains flight vibration reliability by performing subassembly tests at a relatively high acoustic level. Test plans using system testing or combinations of component and assembly level testing are attractive alternatives. Component testing alone is shown not to be cost effective.
NASA Technical Reports Server (NTRS)
1979-01-01
The results of the Coastal Zone Color Scanner protoflight tests are examined in detail while some of the test results are evaluated with respect to expected performance. Performance characteristics examined include spectral response, signal to noise ratio as a function of radiance input, radiance response, the modulation transfer function, and the field of view and coregistration. The results of orbital sequence tests are also included. The in orbit performance or return of radiometric data in the six spectral bands is evaluated along with the data processing sequence necessary to derive the final data products. Examples of the raw data are given and the housekeeping or diagnostic data which provides information on the day to day health or status of the instrument are discussed.
Statistical Analysis of CFD Solutions from the Drag Prediction Workshop
NASA Technical Reports Server (NTRS)
Hemsch, Michael J.
2002-01-01
A simple, graphical framework is presented for robust statistical evaluation of results obtained from N-Version testing of a series of RANS CFD codes. The solutions were obtained by a variety of code developers and users for the June 2001 Drag Prediction Workshop sponsored by the AIAA Applied Aerodynamics Technical Committee. The aerodynamic configuration used for the computational tests is the DLR-F4 wing-body combination previously tested in several European wind tunnels and for which a previous N-Version test had been conducted. The statistical framework is used to evaluate code results for (1) a single cruise design point, (2) drag polars and (3) drag rise. The paper concludes with a discussion of the meaning of the results, especially with respect to predictability, Validation, and reporting of solutions.
NASA Astrophysics Data System (ADS)
Sussman, Joshua Michael
This three-paper dissertation explores problems with the use of standardized tests as outcome measures for the evaluation of instructional interventions in mathematics and science. Investigators commonly use students' scores on standardized tests to evaluate the impact of instructional programs designed to improve student achievement. However, evidence suggests that the standardized tests may not measure, or may not measure well, the student learning caused by the interventions. This problem is special case of a basic problem in applied measurement related to understanding whether a particular test provides accurate and useful information about the impact of an educational intervention. The three papers explore different aspects of the issue and highlight the potential benefits of (a) using particular research methods and of (b) implementing changes to educational policy that would strengthen efforts to reform instructional intervention in mathematics and science. The first paper investigates measurement problems related to the use of standardized tests in applied educational research. Analysis of the research projects funded by the Institute of Education Sciences (IES) Mathematics and Science Education Program permitted me to address three main research questions. One, how often are standardized tests used to evaluate new educational interventions? Two, do the tests appear to measure the same thing that the intervention teaches? Three, do investigators establish validity evidence for the specific uses of the test? The research documents potential problems and actual problems related to the use of standardized tests in leading applied research, and suggests changes to policy that would address measurement issues and improve the rigor of applied educational research. The second paper explores the practical consequences of misalignment between an outcome measure and an educational intervention in the context of summative evaluation. Simulated evaluation data and a psychometric model of alignment grounded in item response modeling generate the results that address the following research question: how do differences between what a test measures and what an intervention teaches influence the results of an evaluation? The simulation derives a functional relationship between alignment, defined as the match between the test and the intervention, and treatment sensitivity, defined as the statistical power for detecting the impact of an intervention. The paper presents a new model of the effect of misalignment on the results of an evaluation and recommendations for outcome measure selection. The third paper documents the educational effectiveness of the Learning Mathematics through Representations (LMR) lesson sequence for students classified as English Learners (ELs). LMR is a research-based curricular unit designed to support upper elementary students' understandings of integers and fractions, areas considered foundational for the development of higher mathematics. The experimental evaluation contains a multilevel analysis of achievement data from two assessments: a standardized test and a researcher-developed assessment. The study coordinates the two sources of research data with a theoretical mechanism of action in order to rigorously document the effectiveness and educational equity of LMR for ELs using multiple sources of information.
NASA Technical Reports Server (NTRS)
Annett, Martin S.; Horta, Lucas G.; Jackson, Karen E.; Polanco, Michael A.; Littell, Justin D.
2012-01-01
Two full-scale crash tests of an MD-500 helicopter were conducted in 2009 and 2010 at NASA Langley's Landing and Impact Research Facility in support of NASA s Subsonic Rotary Wing Crashworthiness Project. The first crash test was conducted to evaluate the performance of an externally mounted composite deployable energy absorber (DEA) under combined impact conditions. In the second crash test, the energy absorber was removed to establish baseline loads that are regarded as severe but survivable. The presence of this energy absorbing device reduced the peak impact acceleration levels by a factor of three. Accelerations and kinematic data collected from the crash tests were compared to a system-integrated finite element model of the test article developed in parallel with the test program. In preparation for the full-scale crash test, a series of sub-scale and MD-500 mass simulator tests were conducted to evaluate the impact performances of various components and subsystems, including new crush tubes and the DEA blocks. Parameters defined for the system-integrated finite element model were determined from these tests. Results from 19 accelerometers placed throughout the airframe were compared to finite element model responses. The model developed for the purposes of predicting acceleration responses from the first crash test was inadequate when evaluating more severe conditions seen in the second crash test. A newly developed model calibration approach that includes uncertainty estimation, parameter sensitivity, impact shape orthogonality, and numerical optimization was used to calibrate model results for the full-scale crash test without the DEA. This combination of heuristic and quantitative methods identified modeling deficiencies, evaluated parameter importance, and proposed required model changes. The multidimensional calibration techniques presented here are particularly effective in identifying model adequacy. Acceleration results for the calibrated model were compared to test results and the original model results. There was a noticeable improvement in the pilot and copilot region, a slight improvement in the occupant model response, and an over-stiffening effect in the passenger region. One lesson learned was that this approach should be adopted early on, in combination with the building-block approaches that are customarily used, for model development and pretest predictions. Complete crash simulations with validated finite element models can be used to satisfy crash certification requirements, potentially reducing overall development costs.
Evaluation of Two Guralp Preamplifiers for GS21 Seismometer Application.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merchant, Bion J.; Slad, George William
2015-08-01
Sandia National Laboratories has tested and evaluated two Guralp preamplifiers for use with a GS21 seismometer application. The two preamplifiers have a gain factor of 61.39. The purpose of the preamplifier evaluation was to determine a measured gain factor, transfer function, total harmonic distortion, self-noise, application passband, dynamic range, seismometer calibration pass-through, and to comment on any issues encountered during the evaluation. The test results included in this report were in response to static, tonal, and dynamic input signals. The Guralp GS21 preamplifiers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treatymore » Organization (CTBTO). Test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters« less
Nyabenda, A; Briart, C; Deggouj, N; Gersdorff, M
2003-12-01
To date, the effectiveness of balanced rehabilitation for patients with Meniere's syndrome has not been unanimously acknowledged by all physicians and physiotherapists. The purpose of this study is to assess the therapeutic efficacy of rotational exercises in the treatment of disequilibrium for patients with unilateral Meniere's syndrome. Rotational stimuli were used to symmetrize and reduce postrotatory nystagmic response. Three reference sources were used to assess the efficacy of this management: vestibulospinal function tests: pre- and post-treatment results at the Romberg test, the Unterberger-Fukuda stepping test, the Babinski-Weil test, and gait testing with eyes closed; rotational tests: pre- and post-treatment results; and the self-perceived impact of vertigo: assessed by the Dizziness Handicap Inventory (DHI) and a scale based on the guidelines of the Japanese Society of Equilibrium Research (JSER, 1993). The JSER scale provides quantitative vertigo evaluation; the DHI reflects the patient's perceptual evaluation of handicap. Patients required 11 sessions (mean value) to attain subjective improvement. Of the 23 patients, only seven required optokinetic stimulation (mean requirement: three sessions). Rotational tests and dynamic tests of the vestibulospinal function improved. The DHI and JSER results show that patients' post-rehabilitation perceptual evaluation significantly improved. The objective and subjective measures of disequilibrium in patients with unilateral Meniere's syndrome were significantly improved.
The report gives results of field tests conducted to determine the emission characteristics of a Babcock and Wilcox Circular burner and Dual Register burner (DRB). The field tests were performed at two utility boilers, generally comparable in design and size except for the burner...
Evaluation of an Audio Cassette Tape Lecture Course
ERIC Educational Resources Information Center
Blank, Jerome W.
1975-01-01
An audio-cassette continuing education course (Selected Topics in Pharmacology) from Extension Services in Pharmacy at the University of Wisconsin was offered to a selected test market of pharmacists and evaluated using a pre-, post-test design. Results showed significant increase in cognitive knowledge and strong approval of students. (JT)
Evaluation of the New B-REX Fatigue Testing System for Multi-Megawatt Wind Turbine Blades: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, D.; Musial, W.; Engberg, S.
2004-12-01
The National Renewable Energy Laboratory (NREL) recently developed a new hybrid fatigue testing system called the Blade Resonance Excitation (B-REX) test system. The new system uses 65% less energy to test large wind turbine blades in half the time of NREL's dual-axis forced-displacement test method with lower equipment and operating costs. The B-REX is a dual-axis test system that combines resonance excitation with forced hydraulic loading to reduce the total test time required while representing the operating strains on the critical inboard blade stations more accurately than a single-axis test system. The analysis and testing required to fully implement themore » B-REX was significant. To control unanticipated blade motion and vibrations caused by dynamic coupling between the flap, lead-lag, and torsional directions, we needed to incorporate additional test hardware and control software. We evaluated the B-REX test system under stable operating conditions using a combination of various sensors. We then compared our results with results from the same blade, tested previously using NREL's dual-axis forced-displacement test method. Experimental results indicate that strain levels produced by the B-REX system accurately replicated the forced-displacement method. This paper describes the challenges we encountered while developing the new blade fatigue test system and the experimental results that validate its accuracy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chandler, K.; Eudy, L.
2009-01-01
This is an evaluation of hydrogen fuel cell transit buses operating at AC Transit in revenue service since March 20, 2006 compared to similar diesel buses operating from the same depot. This evaluation report includes results from November 2007 through October 2008. Evaluation results include implementation experience, fueling station operation, fuel cell bus operations at Golden Gate Transit, and evaluation results at AC Transit (bus usage, availability, fuel economy, maintenance costs, and roadcalls).
On the Effective Evaluation of TCP
NASA Technical Reports Server (NTRS)
Allman, Mark; Falk, Aaron
2000-01-01
Understanding the performance of the Internet's Transmission Control Protocol (TCP) is important because it is the dominant protocol used in the Internet today. Various testing methods exist to evaluate TCP performance, however all have pitfalls an that need to be understood prior to obtaining useful results. Simulating TCP is difficult because of the wide range of variables, environments, and implementations available. Testing TCP modifications in the global Internet may not be the answer either: testing new protocols on real networks endangers other people's traffic and, if not done correctly, may also yield inaccurate or misleading results. In order for TCP research to be independently evaluated in the Internet research community there is a set of questions that researchers should try to answer. This paper attempts to list some of those questions and make recommendations as to how TCP testing can be structured to be provide useful answers.
Flight service evaluation of composite helicopter components
NASA Technical Reports Server (NTRS)
Mardoian, G. H.; Ezzo, M. B.
1986-01-01
This report presents an assessment of composite helicopter tail rotor spars and horizontal stabilizers, exposed to the effects of the environment, after up to five and a half years of commercial service. This evaluation is supported by test results of helicopter components and panels which have been exposed to outdoor environmental effects since September 1979. Full scale static and fatigue tests have been conducted on graphite/epoxy and Kevlar/epoxy composite components obtained from Sikorsky Model S-76 helicopters in commercial operations in the Gulf Coast region of Louisiana. Small scale static and fatigue tests are being conducted on coupons obtained from panels under exposure to outdoor conditions in Stratford, Connecticut and West Palm, Florida. The panel layups are representative of the S-76 components. Additionally, this report discusses the results of moisture absorption evaluations and strength tests on the S-76 components and composite panels with up to five years of outdoor exposure.
Mechanical and bond strength properties of light-cured and chemically cured glass ionomer cements.
McCarthy, M F; Hondrum, S O
1994-02-01
The purpose of this study was to evaluate the mechanical and bond strength properties of a commercially available light-cured glass ionomer cement and of a chemically cured glass ionomer cement. Sixty recently extracted human molars were randomly divided into six equal groups, and the bond strengths of the two cement types were evaluated at 1 hour, 24 hours, and 7 days. Stainless steel lingual buttons were bonded to prepared enamel surfaces, and the samples were placed in a water bath at 37 degrees C until testing. The shear bond strength of each sample was determined with a universal testing instrument. The mechanical strength properties of the two cements were then evaluated. The transverse flexural strength, compressive strength, rigidity, and diametral tensile strength were tested for each cement at 1 hour, 24 hours, and 7 days. The results of the mechanical property strength tests were then compared with the results of the bond strength tests.(ABSTRACT TRUNCATED AT 250 WORDS)
Prestes, R C; Silva, L B; Torri, A M P; Kubota, E H; Rosa, C S; Roman, S S; Kempka, A P; Demiate, I M
2015-07-01
The objective of this work was to evaluate the effect of adding different starches (native and modified) on the physicochemical, sensory, structural and microbiological characteristics of low-fat chicken mortadella. Two formulations containing native cassava and regular corn starch, coded CASS (5.0 % of cassava starch) and CORN (5.0 % of regular corn starch), and one formulation produced with physically treated starch coded as MOD1 (2.5 % of Novation 2300) and chemically modified starch coded as MOD2 (2.5 % of Thermtex) were studied. The following tests were performed: physicochemical characterization (moisture, ash, protein, starch and lipid contents, and water activity); cooling, freezing and reheating losses; texture (texture profile test); color coordinates (L*, a*, b*, C and h); microbiological evaluation; sensory evaluation (multiple comparison and preference test); and histological evaluation (light microscopy). There was no significant difference (p > 0.05) for ash, protein, cooling loss, cohesiveness or in the preference test for the tested samples. The other evaluated parameters showed significant differences (p < 0.05). Histological study allowed for a qualitative evaluation between the physical properties of the food and its microscopic structure. The best results were obtained for formulation MOD2 (2.5 % Thermtex). The addition of modified starch resulted in a better performance than the native starch in relation to the evaluated technological parameters, mainly in relation to reheating losses, which demonstrated the good interaction between the modified starch in the structure of the product and the possibility of the application of this type of starch in other types of functional meat products.
Standardization of carbon-phenolic composite test methodology
NASA Technical Reports Server (NTRS)
Hall, W. B.
1986-01-01
The objective of this study was to evaluate the residual volatiles, filler content, and resin flow test procedures for carbon-phenolic prepreg materials. The residual volatile test procedure was rewritten with tighter procedure control which was then evaluated by round robin testing by four laboratories on the same rolls of prepreg. Results indicated that the residual volatiles test was too operator and equipment dependent to be reliable, and it was recommended that the test be discontinued. The resin flow test procedures were rewritten with tighter procedure control, and it is now considered to be an acceptable test. It was recommended that the filler content determination be made prior to prepregging.
Evaluation of the Waggoner Computerized Color Vision Test.
Ng, Jason S; Self, Eriko; Vanston, John E; Nguyen, Andrew L; Crognale, Michael A
2015-04-01
Clinical color vision evaluation has been based primarily on the same set of tests for the past several decades. Recently, computer-based color vision tests have been devised, and these have several advantages but are still not widely used. In this study, we evaluated the Waggoner Computerized Color Vision Test (CCVT), which was developed for widespread use with common computer systems. A sample of subjects with (n = 59) and without (n = 361) color vision deficiency (CVD) were tested on the CCVT, the anomaloscope, the Richmond HRR (Hardy-Rand-Rittler) (4th edition), and the Ishihara test. The CCVT was administered in two ways: (1) on a computer monitor using its default settings and (2) on one standardized to a correlated color temperature (CCT) of 6500 K. Twenty-four subjects with CVD performed the CCVT both ways. Sensitivity, specificity, and correct classification rates were determined. The screening performance of the CCVT was good (95% sensitivity, 100% specificity). The CCVT classified subjects as deutan or protan in agreement with anomaloscopy 89% of the time. It generally classified subjects as having a more severe defect compared with other tests. Results from 18 of the 24 subjects with CVD tested under both default and calibrated CCT conditions were the same, whereas the results from 6 subjects had better agreement with other test results when the CCT was set. The Waggoner CCVT is an adequate color vision screening test with several advantages and appears to provide a fairly accurate diagnosis of deficiency type. Used in conjunction with other color vision tests, it may be a useful addition to a color vision test battery.
Steel Containment Vessel Model Test: Results and Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Costello, J.F.; Hashimote, T.; Hessheimer, M.F.
A high pressure test of the steel containment vessel (SCV) model was conducted on December 11-12, 1996 at Sandia National Laboratories, Albuquerque, NM, USA. The test model is a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of an improved Mark II boiling water reactor (BWR) containment. A concentric steel contact structure (CS), installed over the SCV model and separated at a nominally uniform distance from it, provided a simplified representation of a reactor shield building in the actual plant. The SCV model and contact structure were instrumented with strain gages and displacement transducers to record the deformationmore » behavior of the SCV model during the high pressure test. This paper summarizes the conduct and the results of the high pressure test and discusses the posttest metallurgical evaluation results on specimens removed from the SCV model.« less
Prefabricated Roof Beams for Hardened Shelters
1993-08-01
beam with a composite concrete slab. Based on the results of the concept evaluation, a test program was designed and conducted to validate the steel...ultimaw, strength. The results of these tests showed that the design procedure accurately predicts the response of the ste,-confined concrete composite...BENDING OF EXTERNALLY REINFORCED CONCRETE BEAMS ........ 67 TABLE 9. SINGLE POINT LOAD BEAM TEST RESULTS
Acoustic results from tests of a 36-inch (0.914 m) diameter statorless lift fan
NASA Technical Reports Server (NTRS)
Stimpert, D. L.
1973-01-01
A statorless, turbotip lift fan was tested statically outdoors to determine its acoustic characteristics. Spectral and directivity results are presented with comparison to data from the same family of lift fan designs having stator vanes. Modifications to the fan were tested to evaluate circular inlet guide vanes and exhaust treatment. A comparison was made of results obtained at General Electric Edwards Flight Test Center and NASA Ames Research Center with regards to test data and differences in site characteristics.
Wimonsate, Wipas; Naorat, Sathapana; Varangrat, Anchalee; Phanuphak, Praphan; Kanggarnrua, Kamolset; McNicholl, Janet; Akarasewi, Passakorn; van Griensven, Frits
2011-05-01
We evaluated factors associated with HIV testing history and returning for HIV test results among 2,049 Thai men who have sex with men. Of men, 50.3% reported prior HIV testing and 24.9% returned for HIV test results. Factors associated with prior HIV testing were male sex work, older age, employed, living away from the family, insertive anal sex role, history of drug use and having heard of effective HIV/AIDS treatment. Factors associated with returning for HIV test results were male sex work, older age, lack of a family confidant, history of sexually transmitted infections, and testing HIV negative in this study.
NASA Astrophysics Data System (ADS)
Giambastiani, Yamuna; Preti, Federico; Errico, Alessandro; Penna, Daniele
2017-04-01
There is growing interest in developing models for predicting how root anchorage and tree bracing could influence tree stability. This work presents the results of different experiments aimed at evaluating the mechanical response of plate roots to pulling tests. Pulling tests have been executed with increasing soil water content and soil of different texture. Different types of tree bracing have been examined for evaluating its impact on plant stiffness. Root plate was anchored with different systems for evaluating the change in overturning resistance. The first results indicate that soil water content contributed to modify both the soil cohesion and the stabilizing forces. Wind effect, slope stability and root reinforcement could be better quantified by means of such a results.
Hercules Aerospace flywheel test results
NASA Astrophysics Data System (ADS)
Steele, R. S., Jr.; Babelay, E. F., Jr.; Sutton, B. J.
1981-06-01
The detailed results of the spin test evaluation of the Hercules Aerospace flywheel at the Oak Ridge Flywheel Evaluation Laboratory (ORFEL) are presented. Details of the static evaluation with radiography and measures of weight, inertia and natural frequencies are included. The flywheel was spun four times with the maximum speed being increased with each run. During the final run, the flywheel achieved 372 rps and stored 0.714 kWhr of kinetic energy at 37 Whr/kg. The ultimate speed was limited by a composite transverse strength that was somewhat lower than that used in the design of the flywheel. This resulted in internal cracking of the flywheel and, eventually, the loss of material from the outer circumference.
Upward Flame Propagation and Wire Insulation Flammability: 2006 Round Robin Data Analysis
NASA Technical Reports Server (NTRS)
Hirsch, David B.
2007-01-01
This viewgraph document reviews test results from tests of different material used for wire insulation for flame propagation and flammability. The presentation focused on investigating data variability both within and between laboratories; evaluated the between-laboratory consistency through consistency statistic h, which indicates how one laboratory s cell average compares with averages from other labs; evaluated the within-laboratory consistency through the consistency statistic k, which is an indicator of how one laboratory s within-laboratory variability compares with the variability of other labs combined; and extreme results were tested to determine whether they resulted by chance or from nonrandom causes (human error, instrument calibration shift, non-adherence to procedures, etc.)
Eustachian tube function in adults without middle ear disease.
Swarts, J Douglas; Alper, Cuneyt M; Mandel, Ellen M; Villardo, Richard; Doyle, William J
2011-04-01
We sought to develop normative values for 5 eustachian tube function (ETF) test protocols in adults without otitis media (OM). Twenty adults (19 to 48 years of age) without a recent history of OM (5 had OM in childhood) underwent unilateral myringotomy and were evaluated for ETF by use of the forced response, inflation, deflation, forcible "sniff", and Valsalva test protocols. When possible, these tests were repeated on a second day. Normative values for the parameters of these protocols in adult subjects without a recent history of OM were developed. Between-day data for the forced response test were highly correlated. A percentage of these tests showed eustachian tube "constriction" during swallowing--an abnormal condition. The percent reduction in applied pressures for the inflation and deflation tests was high, indicative of good ETF. Few subjects had a positive "sniff" test, whereas most had a positive Valsalva test, and the results for both tests were effort-dependent. Results of ETF tests in adults with and without recent OM have not been published. Normative data are now available for comparison with ETF test results in adults with OM. These protocols will be used to evaluate the efficacy of surgical procedures designed to improve ETF.
[NPT (near patient test) in the pharmacy: document and practice guidelines 2008].
Stuard, S; Cesarone, M R; Belcaro, G; Ledda, A; Cornelli, U; Di Renzo, A; Grossi, M G; Pellegrini, L; Gizzi, G; Vinciguerra, G; Dugall, M; Corsi, M; Ippolito, E; Di Palma, T; Zulli, C; Del Boccio, G
2008-10-01
NPT tests in the pharmacy. Blood testing can be made with NPT (near patient testing) directly in the pharmacy. Most tests can be made with a single drop of blood (i.e. from a finger) and results are comparable with results from blood test obtained with standard vein blood samples. NPT is basically used for: 1 - evaluating the risk of a disease. 2 evaluating or confirming the presence of a disease. 3 to manage and monitor treatments. The social role of the pharmacy in NPT (particularly in cardiovascular screening) is very important as the pharmacy is an institution with capillary diffusion in the territory. The pharmacy often constitutes an important, first-level consultancy point for the population, particularly where health institutions are far away (small villages) or not easily accessible. Rules for NPT. Guidelines for NPT testing in the pharmacy have been proposed and discussed in a consensus meeting (Spoleto, 2007). NPT guidelines suggest operating management and technical procedures and indicate prospective lines of action defining new roles for the pharmacy. Coagulation tests can be now made in the pharmacy at a very low cost and with an efficacy comparable to blood tests obtained with a vein sample. Results can be read in seconds. This test is also available for personal use and home testing. NPT: The Clinical Study. The evaluation of the results of a clinical study (patients with venous thrombosis/pulmonary embolisation, patients with fibrillation and patients with artificial cardiac valves) indicates that costing is very favourable for NPT which may reduce costs and improve management of many clinical conditions and their monitoring. Training and control systems help NPT testing to be reliable and useful to screen and manage most clinical and risk conditions. The clinical study also shows the positive correlation between NPT tests and standard' tests. In conclusion NPT tests are now very reliable and cost-effective and can be used for screening, diagnosis and to monitor treatments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, David James; Hedrick, Charles D.; Martinez, Ruben
This report documents tests conducted by Sandia National Laboratories (SNL) on behalf of the U.S. Department of State to evaluate a temporary anti-personnel (TAP) barrier system developed by Mitigation Technologies. For this, the SNL Denial and Structural Assessment department developed a test protocol for the evaluation of the TAP barrier system on the basis of deployment efficiency and barrier effectiveness against a riotous/mob attack threat. The test protocol was then executed by SNL personnel and the results of the testing are documented.
Oxidative stress, d-ROMs test, and ceruloplasmin.
Colombini, Francesco; Carratelli, Mauro; Alberti, Angelo
2016-01-01
Human serum samples were evaluated for oxidative stress with the d-ROMs test. The ceruloplasmin (CP) and copper contents of the samples was independently measured and compared to those calculated on the basis of the d-ROMs test results for pure CP solutions. The d-ROMs readings did not show any significant correlation with either the CP or copper contents of the samples. Critical interference of CP on the d-ROMs test was therefore excluded and the usefulness of the test in the evaluation of global oxidative status of a biological sample could be reassessed.
NASA Technical Reports Server (NTRS)
1971-01-01
A preliminary investigation of the parameters included in run-up dust reactions is presented. Two types of tests were conducted: (1) ignition criteria of large bulk pyrotechnic dusts, and (2) optimal run-up conditions of large bulk pyrotechnic dusts. These tests were used to evaluate the order of magnitude and gross scale requirements needed to induce run-up reactions in pyrotechnic dusts and to simulate at reduced scale an accident that occurred in a manufacturing installation. Test results showed that propagation of pyrotechnic dust clouds resulted in a fireball of relatively long duration and large size. In addition, a plane wave front was observed to travel down the length of the gallery.
Genotoxicity evaluation of So-ochim-tang-gamibang (SOCG), a herbal medicine.
Lee, Mi Young; Park, Yang-Chun; Jin, Mirim; Kim, Eunseok; Choi, Jeong June; Jung, In Chul
2018-02-02
So-ochim-tang-gamibang (SOCG) is a traditional Korean medicine frequently used for depression in the clinical field. In this study, we evaluated the potential genotoxicity of SOCG using three standard batteries of tests as part of a safety evaluation. SOCG was evaluated for potential genotoxic effects using the standard three tests recommended by the Ministry of Food and Drug Safety (MFDS) of Korea. These tests were the bacterial reverse mutation test (Ames test), in vitro mammalian chromosomal aberration test using Chinese hamster lung cells, and in vivo micronucleus test using ICR mice. The Ames test with Salmonella typhimurium strains TA98, TA100, TA1535 and TA1537 and the Escherichia coli strain WP2uvrA(pKM101) showed that SOCG did not induce gene mutations at any dose level in all of the strains. SOCG did not induce any chromosomal aberrations in the in vitro chromosomal aberration test (for both the 6 and 24 h test) and the in vivo micronucleus test. Based on the results of these tests, it was concluded that SOCG does not exhibit any genotoxic risk under the experimental conditions of this study.
Performance evaluation of infrared imaging system in field test
NASA Astrophysics Data System (ADS)
Wang, Chensheng; Guo, Xiaodong; Ren, Tingting; Zhang, Zhi-jie
2014-11-01
Infrared imaging system has been applied widely in both military and civilian fields. Since the infrared imager has various types and different parameters, for system manufacturers and customers, there is great demand for evaluating the performance of IR imaging systems with a standard tool or platform. Since the first generation IR imager was developed, the standard method to assess the performance has been the MRTD or related improved methods which are not perfect adaptable for current linear scanning imager or 2D staring imager based on FPA detector. For this problem, this paper describes an evaluation method based on the triangular orientation discrimination metric which is considered as the effective and emerging method to evaluate the synthesis performance of EO system. To realize the evaluation in field test, an experiment instrument is developed. And considering the importance of operational environment, the field test is carried in practical atmospheric environment. The test imagers include panoramic imaging system and staring imaging systems with different optics and detectors parameters (both cooled and uncooled). After showing the instrument and experiment setup, the experiment results are shown. The target range performance is analyzed and discussed. In data analysis part, the article gives the range prediction values obtained from TOD method, MRTD method and practical experiment, and shows the analysis and results discussion. The experimental results prove the effectiveness of this evaluation tool, and it can be taken as a platform to give the uniform performance prediction reference.
NASA Technical Reports Server (NTRS)
Bond, Thomas H. (Technical Monitor); Anderson, David N.
2004-01-01
This manual reviews the derivation of the similitude relationships believed to be important to ice accretion and examines ice-accretion data to evaluate their importance. Both size scaling and test-condition scaling methods employing the resulting similarity parameters are described, and experimental icing tests performed to evaluate scaling methods are reviewed with results. The material included applies primarily to unprotected, unswept geometries, but some discussion of how to approach other situations is included as well. The studies given here and scaling methods considered are applicable only to Appendix-C icing conditions. Nearly all of the experimental results presented have been obtained in sea-level tunnels. Recommendations are given regarding which scaling methods to use for both size scaling and test-condition scaling, and icing test results are described to support those recommendations. Facility limitations and size-scaling restrictions are discussed. Finally, appendices summarize the air, water and ice properties used in NASA scaling studies, give expressions for each of the similarity parameters used and provide sample calculations for the size-scaling and test-condition scaling methods advocated.
Test results on re-use of reclaimed shower water: Summary. [space stations
NASA Technical Reports Server (NTRS)
Verostko, C. E.; Garcia, R.; Sauer, R.; Linton, A. T.; Elms, T.; Reysa, R. P.
1988-01-01
A microgravity whole body shower (WBS) and waste water recovery systems (WWRS) were evaluated in three separate closed loop tests. Following a protocol similar to that anticipated for the U.S. Space Station, test subjects showered in a prototype whole body shower. The WWRS processes evaluated during the test series were phase change and reverse osmosis (RO). A preprototype Thermoelectric Integrated Hollow Fiber Membrane Evaporation Subsystem phase change process was used for the initial test with chemical pretreatment of the shower water waste input. The second and third tests concentrated on RO technologies. The second test evaluated a dynamic RO membrane consisting of zirconium oxide polyacrylic acid (ZOPA) membranes deposited on the interior diameter of 316L porous stainless steel tubes while the final test employed a thin semipermeable RO membrane deposited on the interior surface of polysulfone hollow fibers. All reclaimed water was post-treated for purity using ion exchange and granular activated carbon beds immediately followed by microbial control treatment using both heat and iodine. The test hardware, controls exercised for whole body showering, types of soaps evaluated, shower subject response to reclaimed water showering, and shower water collection and chemical pretreatment (if required) for microbial control are described. The WWRS recovered water performance and the effectiveness of the reclaimed water post-treatment techniques used for maintaining water purity and microorganism control are compared. Results on chemical and microbial impurity content of the water samples obtained from various locations in the shower water reuse system are summarized.
[Continuing medical education: how to write multiple choice questions].
Soler Fernández, R; Méndez Díaz, C; Rodríguez García, E
2013-06-01
Evaluating professional competence in medicine is a difficult but indispensable task because it makes it possible to evaluate, at different times and from different perspectives, the extent to which the knowledge, skills, and values required for exercising the profession have been acquired. Tests based on multiple choice questions have been and continue to be among the most useful tools for objectively evaluating learning in medicine. When these tests are well designed and correctly used, they can stimulate learning and even measure higher cognitive skills. Designing a multiple choice test is a difficult task that requires knowledge of the material to be tested and of the methodology of test preparation as well as time to prepare the test. The aim of this article is to review what can be evaluated through multiple choice tests, the rules and guidelines that should be taken into account when writing multiple choice questions, the different formats that can be used, the most common errors in elaborating multiple choice tests, and how to analyze the results of the test to verify its quality. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.
Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios
NASA Technical Reports Server (NTRS)
Juarez, Alfredo; Harper, Susana A.
2016-01-01
The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.
Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.
Aralica, Merica; Krleza, Jasna Lenicek
2017-02-15
Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.
Optical fiber reliability results from the Biarritz field trial
NASA Astrophysics Data System (ADS)
Gouronnec, Alain; Goarin, Rolland; Le Moigne, G.; Baptiste, M.
1994-09-01
The first experimental optical fiber network (fiber to the home CATV and video-phone) was installed in BIARRITZ, France) at the beginning or 1980. Some parts of the first optical links have now been removed. FRANCE TELECOM decided to stop field trial services, it appeared interesting to evaluate and expertise fiber reliability after more than 10 years of aging in a real adverse field environment. In this paper we give a short description of the layed down links, and indicate how we have carefully removed the individual fibers from the cables. After a first measurement of the mechanical parameters using normalized dynamic and static tests, we compared the results obtained with those of the equivalent tests used to evaluate these fibers before their installation on the field. The tests used are the same than those used in the 80 th. In conclusion, the paper gives the ageing results measured on the BIARRITZ optical fibers after more than 10 years of service in real environment and evaluate it by comparison with the results before installation.
UNIX-based operating systems robustness evaluation
NASA Technical Reports Server (NTRS)
Chang, Yu-Ming
1996-01-01
Robust operating systems are required for reliable computing. Techniques for robustness evaluation of operating systems not only enhance the understanding of the reliability of computer systems, but also provide valuable feed- back to system designers. This thesis presents results from robustness evaluation experiments on five UNIX-based operating systems, which include Digital Equipment's OSF/l, Hewlett Packard's HP-UX, Sun Microsystems' Solaris and SunOS, and Silicon Graphics' IRIX. Three sets of experiments were performed. The methodology for evaluation tested (1) the exception handling mechanism, (2) system resource management, and (3) system capacity under high workload stress. An exception generator was used to evaluate the exception handling mechanism of the operating systems. Results included exit status of the exception generator and the system state. Resource management techniques used by individual operating systems were tested using programs designed to usurp system resources such as physical memory and process slots. Finally, the workload stress testing evaluated the effect of the workload on system performance by running a synthetic workload and recording the response time of local and remote user requests. Moderate to severe performance degradations were observed on the systems under stress.
Vibroacoustic test plan evaluation: Parameter variation study
NASA Technical Reports Server (NTRS)
Stahle, C. V.; Gongloef, H. R.
1976-01-01
Statistical decision models are shown to provide a viable method of evaluating the cost effectiveness of alternate vibroacoustic test plans and the associated test levels. The methodology developed provides a major step toward the development of a realistic tool to quantitatively tailor test programs to specific payloads. Testing is considered at the no test, component, subassembly, or system level of assembly. Component redundancy and partial loss of flight data are considered. Most and probabilistic costs are considered, and incipient failures resulting from ground tests are treated. Optimums defining both component and assembly test levels are indicated for the modified test plans considered. modeling simplifications must be considered in interpreting the results relative to a particular payload. New parameters introduced were a no test option, flight by flight failure probabilities, and a cost to design components for higher vibration requirements. Parameters varied were the shuttle payload bay internal acoustic environment, the STS launch cost, the component retest/repair cost, and the amount of redundancy in the housekeeping section of the payload reliability model.
Cheyletiella infestation in the dog: observations on diagnostic methods and clinical signs.
Saevik, B K; Bredal, W; Ulstein, T L
2004-10-01
The aims of this study were to evaluate the ability of diagnostic methods to detect naturally occurring Cheyletiella infestation in dogs, and to quantify and relate the number of mites and eggs present to clinical signs. Privately owned dogs with skin problems were eligible for inclusion in the study. Four diagnostic tests were performed on each dog in the following order: tape impression, hair plucking, skin scraping and vacuum cleaning. Dogs with positive test results for Cheyletiella infestation in at least one of the tests under evaluation were included in the study (n=27). The severity of pruritus and scaling was graded on a four-point fixed scale. The diagnostic findings in vacuum cleaning samples provided a semiquantitative measure of the grade of infestation. The vacuum cleaning test gave a positive test result in all dogs and was significantly more efficient than the other tests evaluated (P<0.01). The number of diagnostic findings varied considerably among the different vacuum samples. No significant relationship between the number of diagnostic findings and severity of clinical signs was detected.
NASA Technical Reports Server (NTRS)
Hasan, Mohammad; Balasubramaniam, R.; Nahra, Henry; Mackey, Jeff; Hall, Nancy; Frankenfield, Bruce; Harpster, George; May, Rochelle; Mudawar, Issam; Kharangate, Chirag R.;
2016-01-01
A ground-based experimental facility to perform flow boiling and condensation experiments is built in support of the development of the long duration Flow Boiling and Condensation Experiment (FBCE) destined for operation on board of the International Space Station (ISS) Fluid Integrated Rack (FIR). We performed tests with the condensation test module oriented horizontally and vertically. Using FC-72 as the test fluid and water as the cooling fluid, we evaluated the operational characteristics of the condensation module and generated ground based data encompassing the range of parameters of interest to the condensation experiment to be performed on the ISS. During this testing, we also evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, and the heat loss from different components. In this presentation, we discuss representative results of performance testing of the FBCE flow loop. These results will be used in the refinement of the flight system design and build-up of the FBCE which is scheduled for flight in 2019.
Vasconcellos, Luiz Felipe; Pereira, João Santos; Adachi, Marcelo; Greca, Denise; Cruz, Manuela; Malak, Ana Lara; Charchat-Fichman, Helenice; Spitz, Mariana
2017-01-01
Few studies have evaluated magnetic resonance imaging (MRI) visual scales in Parkinson's disease-Mild Cognitive Impairment (PD-MCI). We selected 79 PD patients and 92 controls (CO) to perform neurologic and neuropsychological evaluation. Brain MRI was performed to evaluate the following scales: Global Cortical Atrophy (GCA), Fazekas, and medial temporal atrophy (MTA). The analysis revealed that both PD groups (amnestic and nonamnestic) showed worse performance on several tests when compared to CO. Memory, executive function, and attention impairment were more severe in amnestic PD-MCI group. Overall analysis of frequency of MRI visual scales by MCI subtype did not reveal any statistically significant result. Statistically significant inverse correlation was observed between GCA scale and Mini-Mental Status Examination (MMSE), Montreal Cognitive Assessment (MoCA), semantic verbal fluency, Stroop test, figure memory test, trail making test (TMT) B, and Rey Auditory Verbal Learning Test (RAVLT). The MTA scale correlated with Stroop test and Fazekas scale with figure memory test, digit span, and Stroop test according to the subgroup evaluated. Visual scales by MRI in MCI should be evaluated by cognitive domain and might be more useful in more severely impaired MCI or dementia patients.
Geometrical optimization of sensors for eddy currents nondestructive testing and evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thollon, F.; Burais, N.
1995-05-01
Design of Non Destructive Testing (NDT) and Non Destructive Evaluation (NDE) sensors is possible by solving Maxwell`s relations with FEM or BIM. But the large number of geometrical and electrical parameters of sensor and tested material implies many results that don`t give necessarily a well adapted sensor. The authors have used a genetic algorithm for automatic optimization. After having tested this algorithm with analytical solution of Maxwell`s relations for cladding thickness measurement, the method has been implemented in finite element package.
Testing and Evaluation of Multifunctional Smart Coatings
NASA Technical Reports Server (NTRS)
Buhrow, Jerry; Li, Wenyan; Jolley, Scott; Calle, Luz M.; Pearman, Benjamin; Zhang, Xuejun
2015-01-01
A smart coating system, based on pH sensitive microcontainers (microparticles and microcapsules) has been developed. Various corrosion inhibitors have been encapsulated and incorporated into commercial and formulated coatings to test the functionality imparted on the coating by the incorporation of the inhibitor microcontainers. Coated carbon steel and aluminum alloy panels were tested using salt immersion, salt fog, and coastal atmospheric exposure conditions. This paper provides the details on coating sample preparation, evaluation methods, as well as test results of the inhibiting function of smart coatings.
Locke, Melissa; Hill, Bridget; Wells, Cherie; Bialocerkowski, Andrea
2017-01-01
Background Clinicians and researchers require sound neurological tests to measure changes in neurological impairments necessary for clinical decision-making. Little evidence-based guidance exists for selecting and interpreting an appropriate, paediatric-specific lower limb neurological test aimed at the impairment level. Objective To determine the clinimetric evidence underpinning neurological impairment tests currently used in paediatric rehabilitation to evaluate muscle strength, tactile sensitivity, and deep tendon reflexes of the lower limb in children and young people with a neurological condition. Methods Thirteen databases were systematically searched in two phases, from the date of database inception to 16 February 2017. Lower limb neurological impairment tests were first identified which evaluated muscle strength, tactile sensitivity or deep tendon reflexes in children or young people under 18 years of age with a neurological condition. Papers containing clinimetric evidence of these tests were then identified. The methodological quality of each paper was critically appraised using standardised tools and clinimetric evidence synthesised for each test. Results Thirteen papers were identified, which provided clinimetric evidence on six neurological tests. Muscle strength tests had the greatest volume of clinimetric evidence, however this evidence focused on reliability. Studies were variable in quality with inconsistent results. Clinimetric evidence for tactile sensitivity impairment tests was conflicting and difficult to extrapolate. No clinimetric evidence was found for impairment tests of deep tendon reflexes. Conclusions Limited high-quality clinimetric evidence exists for lower limb neurological impairment tests in children and young people with a neurological condition. Results of currently used neurological tests, therefore, should be interpreted with caution. Robust clinimetric evidence on these tests is required for clinicians and researchers to effectively select and evaluate rehabilitation interventions. PMID:28671957
Advanced parking information system evaluation report
DOT National Transportation Integrated Search
1997-01-01
This report documents the evaluation analysis and results of the operational test. The evaluation assesses the impact/effect of the advance parking information system on the motoring public, parking facility operators, roadway system operations, and ...
ERIC Educational Resources Information Center
Lansford, Carl E.
As computer aided instruction (CAI) and distance learning become more popular, a model for easily evaluating these teaching methods must be developed, one which will enable replication of the study each year. This paper discusses the results of a study using existing dependent and independent variables to evaluate CAI for developmental reading…
Evaluation of Visualization Software
NASA Technical Reports Server (NTRS)
Globus, Al; Uselton, Sam
1995-01-01
Visualization software is widely used in scientific and engineering research. But computed visualizations can be very misleading, and the errors are easy to miss. We feel that the software producing the visualizations must be thoroughly evaluated and the evaluation process as well as the results must be made available. Testing and evaluation of visualization software is not a trivial problem. Several methods used in testing other software are helpful, but these methods are (apparently) often not used. When they are used, the description and results are generally not available to the end user. Additional evaluation methods specific to visualization must also be developed. We present several useful approaches to evaluation, ranging from numerical analysis of mathematical portions of algorithms to measurement of human performance while using visualization systems. Along with this brief survey, we present arguments for the importance of evaluations and discussions of appropriate use of some methods.
Battery testing at Argonne National Laboratory
NASA Astrophysics Data System (ADS)
Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.
Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis & Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during FY-92 on both single cells and multi-cell modules that encompass six battery technologies (Na/S, Li/FeS, Ni/Metal-Hydride, Ni/Zn, Ni/Cd, Ni/Fe). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.
Werner, Benedikt; von Ramin, Elisabeth; Spruyt, Adriaan; Rothermund, Klaus
2018-02-01
After 30 years of research, the mechanisms underlying the evaluative priming effect are still a topic of debate. In this study, we tested whether the evaluative priming effect can result from (uncontrolled) associative relatedness rather than evaluative congruency. Stimuli that share the same evaluative connotation are more likely to show some degree of non-evaluative associative relatedness than stimuli that have a different evaluative connotation. Therefore, unless associative relatedness is explicitly controlled for, evaluative priming effects reported in earlier research may be driven by associative relatedness instead of evaluative relatedness. To address this possibility, we performed an evaluative priming study in which evaluative congruency and associative relatedness were manipulated independently from each other. The valent/neutral categorisation task was used to ensure evaluative stimulus processing in the absence of response priming effects. Results showed an effect of associative relatedness but no (overall) effect of evaluative congruency. Our findings highlight the importance of controlling for associative relatedness when testing for evaluative priming effects.
Final Test and Evaluation Results from the Solar Two Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
BRADSHAW, ROBERT W.; DAWSON, DANIEL B.; DE LA ROSA, WILFREDO
Solar Two was a collaborative, cost-shared project between 11 U. S. industry and utility partners and the U. S. Department of Energy to validate molten-salt power tower technology. The Solar Two plant, located east of Barstow, CA, comprised 1926 heliostats, a receiver, a thermal storage system, a steam generation system, and steam-turbine power block. Molten nitrate salt was used as the heat transfer fluid and storage media. The steam generator powered a 10-MWe (megawatt electric), conventional Rankine cycle turbine. Solar Two operated from June 1996 to April 1999. The major objective of the test and evaluation phase of the projectmore » was to validate the technical characteristics of a molten salt power tower. This report describes the significant results from the test and evaluation activities, the operating experience of each major system, and overall plant performance. Tests were conducted to measure the power output (MW) of the each major system, the efficiencies of the heliostat, receiver, thermal storage, and electric power generation systems and the daily energy collected, daily thermal-to-electric conversion, and daily parasitic energy consumption. Also included are detailed test and evaluation reports.« less
Overview of CEV Thermal Protection System Seal Development
NASA Technical Reports Server (NTRS)
DeMange, Jeff; Taylor, Shawn; Dunlap, Patrick; Steinetz, Bruce; Delgado, Irebert; Finkbeiner, Josh; Mayer, John
2009-01-01
NASA GRC supporting design, development, and implementation of numerous seal systems for the Orion CEV: a) HS-to-BS interface. b) Compression pad. HS-to-BS Interface Seal System: a) design has evolved as a result of changes with the CEV TPS. b) Seal system is currently under development/evaluation. Coupon level tests, Arc jet tests, and Validation test development. Compression Pad: a) Finalizing design options. b) Evaluating material candidates.
Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.; ...
2017-12-12
The ANSI/HPS N13.1–2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF 6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N 2O) was evaluated as a potential replacement to SF 6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position,more » and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF 6 modeling corroborated N 2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N 2O testing to SF 6 testing in the context of stack qualification tests. In conclusion, the results demonstrate that N 2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.
The ANSI/HPS N13.1–2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF 6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N 2O) was evaluated as a potential replacement to SF 6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position,more » and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF 6 modeling corroborated N 2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N 2O testing to SF 6 testing in the context of stack qualification tests. In conclusion, the results demonstrate that N 2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.« less
Sachdeva, Rohit; Sharma, Babita; Sharma, Rajni
2017-01-01
PURPOSE: Pseudomonas aeruginosa causes a wide spectrum of infections including bacteremia, pneumonia, urinary tract infection, etc., Metallo-beta-lactamase (MBL) producing P. aeruginosa is an emerging threat and cause of concern as they have emerged as one of the most feared resistance mechanisms. This study was designed to know the prevalence of MBL production in P. aeruginosa and to evaluate the four phenotypic tests for detection of MBL production in imipenem-resistant clinical isolates of P. aeruginosa. METHODS: Totally, 800 isolates of P. aeruginosa isolated from various clinical samples were evaluated for carbapenem resistance and MBL production. All imipenem-resistant strains were tested for carabapenemase production by modified Hodge test. Screening for MBL production was done by double-disc synergy test and combined disc test (CDT). Confirmation of MBL production was done by the E-test (Ab BioDisk, Solna, Sweden). RESULTS: Out of the 800 isolates of P. aeruginosa, 250 isolates were found resistant to imipenem. Based on the results of E-test, 147 (18.37%) isolates of P. aeruginosa were positive for MBL production. The CDT has the highest sensitivity and specificity for the detection of MBL production as compared to other tests. CONCLUSION: The results of this study are indicative that MBL production is an important mechanism of carbapenem resistance among P. aeruginosa. Use of simple screening test like CDT will be crucial step toward large-scale monitoring of these emerging resistant determinants. Phenotypic test for MBL production has to be standardized, and all the isolates should be routinely screened for MBL production. PMID:28966485
Test and evaluation of Japanese GPR-EMI dual sensor systems at Benkovac test site in Croatia
NASA Astrophysics Data System (ADS)
Ishikawa, J.; Furuta, K.; Pavković, Nikola
2007-04-01
This paper presents an experimental design and the evaluation result of a trial that were carried out from 1 February to 9 March 2006 using real PMA-1A and PMA-2 landmines at the Benkovac test site in Croatia. The objective of the Croatia- Japan joint trial is to evaluate dual sensor systems, which use both ground penetrating radar (GPR) and electromagnetic inductive (EMI) sensors. A comparative trial was also carried out by Croatian deminers using an existing EMI sensor, i.e., a metal detector (MD). The trial aims at evaluating differences in performance between dual sensors and MDs, especially in terms of discrimination of landmines from metal fragments and extension of detectable range in the depth direction. Devices evaluated here are 4 prototypes of anti-personnel landmine detection systems developed under a project of the Japan Science and Technology Agency (JST), the supervising authority of which is the Ministry of Education, Culture, Sports, Science and Technology (MEXT). The prototypes provide operators with subsurface images, and final decision whether a shadow in the image is a real landmine or not is left to the operator. This is similar to the way that medical doctors find cancer by reading CT images. Since operators' pre-knowledge of locations of buried targets significantly influences the test result, three test lanes, which have 3 different kinds of soils, have been designed to be suitable for blind tests. The result showed that the dual sensor systems have a potential to discriminate landmines from metal fragments and that probability of detection for small targets in mineralized soils can be improved by using GPR.
Objective speech quality evaluation of real-time speech coders
NASA Astrophysics Data System (ADS)
Viswanathan, V. R.; Russell, W. H.; Huggins, A. W. F.
1984-02-01
This report describes the work performed in two areas: subjective testing of a real-time 16 kbit/s adaptive predictive coder (APC) and objective speech quality evaluation of real-time coders. The speech intelligibility of the APC coder was tested using the Diagnostic Rhyme Test (DRT), and the speech quality was tested using the Diagnostic Acceptability Measure (DAM) test, under eight operating conditions involving channel error, acoustic background noise, and tandem link with two other coders. The test results showed that the DRT and DAM scores of the APC coder equalled or exceeded the corresponding test scores fo the 32 kbit/s CVSD coder. In the area of objective speech quality evaluation, the report describes the development, testing, and validation of a procedure for automatically computing several objective speech quality measures, given only the tape-recordings of the input speech and the corresponding output speech of a real-time speech coder.
Fernandez Montenegro, Juan Manuel; Argyriou, Vasileios
2017-05-01
Alzheimer's screening tests are commonly used by doctors to diagnose the patient's condition and stage as early as possible. Most of these tests are based on pen-paper interaction and do not embrace the advantages provided by new technologies. This paper proposes novel Alzheimer's screening tests based on virtual environments and game principles using new immersive technologies combined with advanced Human Computer Interaction (HCI) systems. These new tests are focused on the immersion of the patient in a virtual room, in order to mislead and deceive the patient's mind. In addition, we propose two novel variations of Turing Test proposed by Alan Turing as a method to detect dementia. As a result, four tests are introduced demonstrating the wide range of screening mechanisms that could be designed using virtual environments and game concepts. The proposed tests are focused on the evaluation of memory loss related to common objects, recent conversations and events; the diagnosis of problems in expressing and understanding language; the ability to recognize abnormalities; and to differentiate between virtual worlds and reality, or humans and machines. The proposed screening tests were evaluated and tested using both patients and healthy adults in a comparative study with state-of-the-art Alzheimer's screening tests. The results show the capacity of the new tests to distinguish healthy people from Alzheimer's patients. Copyright © 2017. Published by Elsevier Inc.
Calibration of Airframe and Occupant Models for Two Full-Scale Rotorcraft Crash Tests
NASA Technical Reports Server (NTRS)
Annett, Martin S.; Horta, Lucas G.; Polanco, Michael A.
2012-01-01
Two full-scale crash tests of an MD-500 helicopter were conducted in 2009 and 2010 at NASA Langley's Landing and Impact Research Facility in support of NASA s Subsonic Rotary Wing Crashworthiness Project. The first crash test was conducted to evaluate the performance of an externally mounted composite deployable energy absorber under combined impact conditions. In the second crash test, the energy absorber was removed to establish baseline loads that are regarded as severe but survivable. Accelerations and kinematic data collected from the crash tests were compared to a system integrated finite element model of the test article. Results from 19 accelerometers placed throughout the airframe were compared to finite element model responses. The model developed for the purposes of predicting acceleration responses from the first crash test was inadequate when evaluating more severe conditions seen in the second crash test. A newly developed model calibration approach that includes uncertainty estimation, parameter sensitivity, impact shape orthogonality, and numerical optimization was used to calibrate model results for the second full-scale crash test. This combination of heuristic and quantitative methods was used to identify modeling deficiencies, evaluate parameter importance, and propose required model changes. It is shown that the multi-dimensional calibration techniques presented here are particularly effective in identifying model adequacy. Acceleration results for the calibrated model were compared to test results and the original model results. There was a noticeable improvement in the pilot and co-pilot region, a slight improvement in the occupant model response, and an over-stiffening effect in the passenger region. This approach should be adopted early on, in combination with the building-block approaches that are customarily used, for model development and test planning guidance. Complete crash simulations with validated finite element models can be used to satisfy crash certification requirements, thereby reducing overall development costs.
Yokoi, Masako; Hattori, Koji; Narikawa, Koichi; Ohgushi, Hajime; Tadokoro, Mika; Hoshi, Kazuto; Takato, Tsuyoshi; Myoui, Akira; Nanno, Katsuhiko; Kato, Yukio; Kanawa, Masami; Sugawara, Katsura; Kobo, Tomoko; Ushida, Takashi
2012-07-01
Tissue-engineered medical products (TEMPs) should be evaluated before implantation. Therefore, it is indispensable to establish evaluation protocols in regenerative medicine. Whether or not such evaluation protocols are reasonable is generally verified through a 'round robin' test. However, the round robin test for TEMPs intrinsically includes a deficiency, because 'identical' specimens can not be prepared for TEMPs. The aim of the study was to assess the feasibility and limitations of the round robin test for TEMPs by using a prepared evaluation protocol. We adopted tissue-engineered cartilage constructs as delivered specimens and a protocol of measuring sGAG content as an evaluation protocol proposed to ISO TC150/SC7, which is an invasive, but usually applied, method, although non-invasive methods are keenly required in evaluating TEMPs. The results showed that: (a) the coefficient of variation (CV) of the measured sGAG contents in intralaboratory tests was ~5% at most; (b) the CV of sGAG content in the scheme where each participating laboratory measured different constructs was comparable with that in the scheme where each participating laboratory measured one half of a construct along with the organizing laboratory; (c) the CV caused by factors other than the specimen was ~15%, comparable to that in reproducible experiments in biomedical fields. Based on these results, the study concludes that a round robin test for a TEMP could be valuable, under the condition that the delivered TEMPs are sufficiently reproducible so that the CV of the measured values is < 5% in the organizing laboratory. Copyright © 2011 John Wiley & Sons, Ltd.
Investigation of Test Methods, Material Properties and Processes for Solar Cell Encapsulants
NASA Technical Reports Server (NTRS)
Willis, P.; Baum, B.
1982-01-01
The evaluation of potentially useful low cost encapsulation materials is discussed. The goal is to identify, evaluate, test and recommend encapsulant materials and processes for the production of cost effective, long life solar cell modules. Technical investigations concerned the development of advanced cure chemistries for lamination type pottants; the continued evaluation of soil resistant surface treatment, and the results of an accelerated aging test program for the comparison of material stabilities. New compounds were evaluated for efficiency in curing both ethylene/vinyl acetate and ethylene/methyl acrylate pottants intended for vacuum bag lamination of solar cells. Two component aliphatic urethane casting syrups were evaluated for suitability as solar module pottants on the basis of optical, physical and fabrication characteristics.
Weightless Environment Training Facility (WETF) Materials Coating Evaluation, Volume 1
NASA Technical Reports Server (NTRS)
1995-01-01
The Weightless Environment Training Facility Material Coating Evaluation project has included preparing, coating, testing, and evaluating 800 test panels of three differing substrates. Ten selected coating systems were evaluated in six separate exposure environments and subject to three tests for physical properties. Substrate materials were identified, the manner of surface preparation described, and exposure environments defined. Exposure environments included immersion exposure, cyclic exposure, and field exposure. Cyclic exposures, specifically QUV-Weatherometer and the KTA Envirotest were found to be the most agressive of the environments included in the study when all three evaluation criteria are considered. This was found to result primarily from chalking of the coatings under ultraviolet (UV) light exposure. Volumes 2 and 3 hold the 5 appendices to this report.
Test results for SEU and SEL immune memory circuits
NASA Technical Reports Server (NTRS)
Wiseman, D.; Canaris, J.; Whitaker, S.; Gambles, J.; Arave, K.; Arave, L.
1993-01-01
Test results for three SEU logic/circuit hardened CMOS memory circuits verify upset and latch-up immunity for two configurations to be in excess of 120 MeV cm(exp 2)/mg using a commercial, non-radiation hardened CMOS process. Test chips from three separate fabrication runs in two different process were evaluated.
Your Chi-Square Test Is Statistically Significant: Now What?
ERIC Educational Resources Information Center
Sharpe, Donald
2015-01-01
Applied researchers have employed chi-square tests for more than one hundred years. This paper addresses the question of how one should follow a statistically significant chi-square test result in order to determine the source of that result. Four approaches were evaluated: calculating residuals, comparing cells, ransacking, and partitioning. Data…
Smartphone-Based Point-of-Care Urinalysis Under Variable Illumination
Ra, Moonsoo; Lim, Chiawei; Han, Sehui; Jung, Chansung; Kim, Whoi-Yul
2018-01-01
Urine tests are performed by using an off-the-shelf reference sheet to compare the color of test strips. However, the tabular representation is difficult to use and more prone to visual errors, especially when the reference color-swatches to be compared are spatially apart. Thus, making it is difficult to distinguish between the subtle differences of shades on the reagent pads. This manuscript represents a new arrangement of reference arrays for urine test strips (urinalysis). Reference color swatches are grouped in a doughnut chart, surrounding each reagent pad on the strip. The urine test can be evaluated using naked eye by referring to the strip with no additional sheet necessary. Along with this new strip, an algorithm for smartphone based application is also proposed as an alternative to deliver diagnostic results. The proposed colorimetric detection method evaluates the captured image of the strip, under various color spaces and evaluates ten different tests for urine. Thus, the proposed system can deliver results on the spot using both naked eye and smartphone. The proposed scheme delivered accurate results under various environmental illumination conditions without any calibration requirements, exhibiting performances suitable for real-life applications and an ease for a common user. PMID:29333352
Results of advanced battery technology evaluations for electric vehicle applications
NASA Astrophysics Data System (ADS)
Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.
1992-10-01
Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis and Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during 1991-1992 on both single cells and multi-cell modules that encompass eight battery technologies (Na/S, Li/MS (M=metal), Ni/MH, Ni/Cd, Ni/Zn, Ni/Fe, Zn/Br, and Pb-acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most-promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.
Cook, A K; Gilson, S D; Fischer, W D; Kass, P H
1992-10-01
To evaluate the effect of diet on results obtained by use of 2 commercial test kits for detection of occult blood in feces, 5 dogs were fed 7 diets in randomized sequence. Dry and canned diets with various principal ingredients were evaluated. Each diet was offered twice over a 24-hour period, followed by a 36-hour nonfeeding period. Fecal specimens were collected twice daily, and tests for occult blood were performed within 12 hours. The dietary origin of fecal specimens was confirmed by use of colored markers fed with each diet, and was correlated with estimates of gastrointestinal tract transit time. A modified guaiac paper test and an o-tolidine tablet test were performed on each specimen. Of 59 specimens, 4 were positive for occult blood, using the o-tolidine tablet test. Three positive results were associated with a mutton-based canned diet, and 1 positive result was associated with a canned beef-based diet. Of 59 specimens, 11 were positive for occult blood, using the modified guaiac paper test. Four positive results were associated with the mutton diet, and 3 positive results were associated with the beef diet. Of the remaining 5 diets, 4 caused 1 positive reaction. Results were inconsistent with the null hypothesis that the distribution of positive occult blood test results is not affected by diet (P < 0.025), and indicate that diet can affect the specificity of peroxidase-based tests for detection of occult blood in canine feces. Diet modification prior to testing is recommended.
NASA Astrophysics Data System (ADS)
Liu, Xiaoyu; Mason, Mark A.; Guo, Zhishi; Krebs, Kenneth A.; Roache, Nancy F.
2015-12-01
This paper describes the measurement and model evaluation of formaldehyde source emissions from composite and solid wood furniture in a full-scale chamber at different ventilation rates for up to 4000 h using ASTM D 6670-01 (2007). Tests were performed on four types of furniture constructed of different materials and from different manufacturers. The data were used to evaluate two empirical emission models, i.e., a first-order and power-law decay model. The experimental results showed that some furniture tested in this study, made only of solid wood and with less surface area, had low formaldehyde source emissions. The effect of ventilation rate on formaldehyde emissions was also examined. Model simulation results indicated that the power-law decay model showed better agreement than the first-order decay model for the data collected from the tests, especially for long-term emissions. This research was limited to a laboratory study with only four types of furniture products tested. It was not intended to comprehensively test or compare the large number of furniture products available in the market place. Therefore, care should be taken when applying the test results to real-world scenarios. Also, it was beyond the scope of this study to link the emissions to human exposure and potential health risks.
This document provides a comprehensive review to evaluate the reliability of indicator species toxicity test results in predicting aquatic ecosystem impacts, also called the ecological relevance of laboratory single species toxicity tests.
Determinants of maximal oxygen uptake (VO2 max) in fire fighter testing.
Vandersmissen, G J M; Verhoogen, R A J R; Van Cauwenbergh, A F M; Godderis, L
2014-07-01
The aim of this study was to evaluate current daily practice of aerobic capacity testing in Belgian fire fighters. The impact of personal and test-related parameters on the outcome has been evaluated. Maximal oxygen uptake (VO2 max) results of 605 male fire fighters gathered between 1999 and 2010 were analysed. The maximal cardio respiratory exercise tests were performed at 22 different centres using different types of tests (tread mill or bicycle), different exercise protocols and measuring equipment. Mean VO2 max was 43.3 (SD = 9.8) ml/kg.min. Besides waist circumference and age, the type of test, the degree of performance of the test and the test centre were statistically significant determinants of maximal oxygen uptake. Test-related parameters have to be taken into account when interpreting and comparing maximal oxygen uptake tests of fire fighters. It highlights the need for standardization of aerobic capacity testing in the medical evaluation of fire fighters. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Koppelman, Marco H G M; Cuijpers, H Theo M; Wessberg, Susanna; Valkeajärvi, Anne; Pichl, Lutz; Schottstedt, Volkmar; Saldanha, John
2012-07-01
Three European laboratories evaluated the TaqScreen DPX test (DPX test), a multiplex nucleic acid test assay for the simultaneous detection and quantitation of parvovirus B19 (B19V) DNA and the detection of hepatitis A virus (HAV) RNA. The 95% limit of detection of the test for B19V and HAV was determined using the respective WHO International Standards. The reproducibility of the test was evaluated by testing replicate samples of B19V at log 4.0 and 40 IU/mL and HAV at 5 IU/mL. The accuracy of the DPX test for B19V was evaluated by replicate testing of B19V samples containing log 3.0, log 4.0, and log 5.0 IU/mL. Panels of B19V Genotypes 1, 2, and 3 and HAV genotypes were evaluated. Cross-contamination was evaluated. For comparison of the DPX test and the established tests, the sites tested plasma samples in pools of either 96 or 480 donations. The mean 95% lower limits of detection of the three laboratories for B19V and HAV were 20.30 and 1.85 IU/mL. The test showed good reproducibility with the major part of the variance of the test being attributed to intermediate assay variation. The test showed great accuracy for B19V, especially at log 4.0 IU/mL. Spiking of test pools of 480 donations and manufacturing pools with log 4.0 IU/mL B19 DNA and 4 IU/mL HAV RNA showed that the DPX assay was robust. The test was able to detect the three genotypes of B19V and HAV genotypes. No cross-contamination was seen. Test results of routine samples correlated well with those of the established tests. The DPX test is a robust and sensitive test for the detection of B19V and HAV in plasma samples. The quantitative B19V results obtained with the test are accurate, and the test is able to detect all the known genotypes of B19V and HAV and fulfills all the European Pharmacopoeia and Food and Drug Administration requirements for a B19V and HAV test for screening of plasma donations and samples from plasma pools for manufacture. © 2012 American Association of Blood Banks.
Kim, Saorin; Nhem, Sina; Dourng, Dany; Ménard, Didier
2015-03-14
Malaria rapid diagnostic tests (RDTs) are generally considered as point-of-care tests. However, most of the studies assessing the performance of malaria RDTs are conducted by research teams that are not representative of the classical end-users, who are typically unskilled in traditional laboratory techniques for diagnosing malaria. To evaluate the performance of a malaria RDT by end-users in a malaria-endemic area, a study protocol was designed and the VIKIA Malaria Ag Pf/Pan test, previously evaluated in 2013, was re-evaluated by representative end-users. Twenty end-users with four different profiles in seven communes in Kampot Province (Cambodia) were selected. A set of 20 calibrated aliquots, including negative samples, low positive samples (200 parasites/μL of Plasmodium falciparum and Plasmodium vivax) and high positive samples (2,000 parasites/μL of P. falciparum and P. vivax) was used. Testing was performed directly by the end-users without any practical training on the VIKIA Malaria Ag Pf/Pan kit. All results obtained by the end-users were consistent with the expected results, except for the low positive (200 parasites/μL) P. vivax aliquot (35% of concordant results). No significant difference was observed between the different end-users. End-user interviews evaluating ease-of-use and ease-of-reading of the VIKIA Malaria Ag Pf/Pan kit recorded 159 positive answers and only one negative answer. Out of 20 end-users, only one considered the test was not easy to perform with the support of the quick guide. The data presented in this study clearly demonstrate that the performance of the VIKIA Malaria Ag Pf/Pan test when performed by traditional end-users in field conditions is similar to that obtained by a research team and that this RDT can be considered as a point-of-care tool/assay. Furthermore, the protocol designed for this study could be used systematically in parallel to conventional evaluation studies to determine the performance of malaria RDTs in field conditions.
NASA Technical Reports Server (NTRS)
Shih, K.
1977-01-01
The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.
Widder, Mark W; Brennan, Linda M; Hanft, Elizabeth A; Schrock, Mary E; James, Ryan R; van der Schalie, William H
2015-07-01
The US Army's need for a reliable and field-portable drinking water toxicity sensor was the catalyst for the development and evaluation of an electric cell-substrate impedance sensing (ECIS) device. Water testing technologies currently available to soldiers in the field are analyte-specific and have limited capabilities to detect broad-based water toxicity. The ECIS sensor described here uses rainbow trout gill epithelial cells seeded on fluidic biochips to measure changes in impedance for the detection of possible chemical contamination of drinking water supplies. Chemicals selected for testing were chosen as representatives of a broad spectrum of toxic industrial compounds. Results of a US Environmental Protection Agency (USEPA)-sponsored evaluation of the field portable device were similar to previously published US Army testing results of a laboratory-based version of the same technology. Twelve of the 18 chemicals tested following USEPA Technology Testing and Evaluation Program procedures were detected by the ECIS sensor within 1 h at USEPA-derived human lethal concentrations. To simplify field-testing methods further, elimination of a procedural step that acclimated cells to serum-free media streamlined the test process with only a slight loss of chemical sensitivity. For field use, the ECIS sensor will be used in conjunction with an enzyme-based sensor that is responsive to carbamate and organophosphorus pesticides. Copyright © 2014 John Wiley & Sons, Ltd.
Flight service evaluation of composite helicopter components
NASA Technical Reports Server (NTRS)
Rich, M. J.; Lowry, D. W.
1985-01-01
An assessment of composite helicopter structures, exposed to environmental effects, after four years of commercial service is presented. This assessment is supported by test results of helicopter components and test panels which have been exposed to environmental effects since late 1979. Full scale static and fatigue tests are being conducted on composite components obtained from S-76 helicopters in commercial operations in the Gulf Coast region of Louisiana. Small scale tests are being conducted on coupons obtained from panels being exposed to outdoor conditions in Stratford, Connecticut and West Palm Beach, Florida. The panel layups represent S-76 components. Moisture evaluations and strength tests are being conducted, on the S-76 components and panels, over a period of eight years. Results are discussed for components and panels with up to four years of exposure.
Measured effects of coolant injection on the performance of a film cooled turbine
NASA Technical Reports Server (NTRS)
Mcdonel, J. D.; Eiswerth, J. E.
1977-01-01
Tests have been conducted on a 20-inch diameter single-stage air-cooled turbine designed to evaluate the effects of film cooling air on turbine aerodynamic performance. The present paper reports the results of five test configurations, including two different cooling designs and three combinations of cooled and solid airfoils. A comparison is made of the experimental results with a previously published analytical method of evaluating coolant injection effects on turbine performance.
Evaluation of direct-to-consumer low-volume lab tests in healthy adults.
Kidd, Brian A; Hoffman, Gabriel; Zimmerman, Noah; Li, Li; Morgan, Joseph W; Glowe, Patricia K; Botwin, Gregory J; Parekh, Samir; Babic, Nikolina; Doust, Matthew W; Stock, Gregory B; Schadt, Eric E; Dudley, Joel T
2016-05-02
Clinical laboratory tests are now being prescribed and made directly available to consumers through retail outlets in the USA. Concerns with these test have been raised regarding the uncertainty of testing methods used in these venues and a lack of open, scientific validation of the technical accuracy and clinical equivalency of results obtained through these services. We conducted a cohort study of 60 healthy adults to compare the uncertainty and accuracy in 22 common clinical lab tests between one company offering blood tests obtained from finger prick (Theranos) and 2 major clinical testing services that require standard venipuncture draws (Quest and LabCorp). Samples were collected in Phoenix, Arizona, at an ambulatory clinic and at retail outlets with point-of-care services. Theranos flagged tests outside their normal range 1.6× more often than other testing services (P < 0.0001). Of the 22 lab measurements evaluated, 15 (68%) showed significant interservice variability (P < 0.002). We found nonequivalent lipid panel test results between Theranos and other clinical services. Variability in testing services, sample collection times, and subjects markedly influenced lab results. While laboratory practice standards exist to control this variability, the disparities between testing services we observed could potentially alter clinical interpretation and health care utilization. Greater transparency and evaluation of testing technologies would increase their utility in personalized health management. This work was supported by the Icahn Institute for Genomics and Multiscale Biology, a gift from the Harris Family Charitable Foundation (to J.T. Dudley), and grants from the NIH (R01 DK098242 and U54 CA189201, to J.T. Dudley, and R01 AG046170 and U01 AI111598, to E.E. Schadt).
Huber, H; Brambrink, M; Funk, R; Rieger, M
2012-10-01
The purpose of this study was to evaluate differences in the D-DRG results of a hospital case by 2 independently coding MKD raters. Calculation of the 2-inter-rater reliability was performed by examination of the coding of individual hospital cases. The reasons for the non-agreement of the expert evaluations and suggestions to improve the process are discussed. From the expert evaluation pool of the MDK-WL a random sample of 0.7% of the 57,375 expertises was taken. Distribution equality with the basic total was tested by the χ² test or, respectively, Fisher's exact test. For the total of 402 individual hospital cases, the G-DRG case sums of 2 experts of the MDK were determined independently and the results checked for each individual case for agreement or non-agreement. The corresponding confidence intervals with standard errors were analysed to test if certain major diagnosis categories (MDC) were statistically significantly more affected by differing expertise results than others. In 280 of the total 402 tested hospital cases, the 2 MDK raters independently reached the same G-DRG results; in 122 cases the G-DRG case sums determined by the 2 raters differed (agreement 70%; CI 65.2-74.1). Different DRG results between the 2 experts occurred regularly in the entire MDC spectrum. No MDC chapter in which significant differences between the 2 raters arose could be identified. The results of our study demonstrate an almost 70% agreement in the evaluation of hospital cost accounts by 2 independently operating MDK. This result leaves room for improvement. Optimisation potentials can be recognised on the basis of the results. Potential for improvement was established in combination with regular further training and the expansion of binding internal code recommendations as well as exchange of code-relevant information among experts in internal forums. The presented model is in principle suitable for cross-border examinations within the MDK system with the advantage that further trends could be uncovered by more variety and larger numbers of the randomly selected cases. © Georg Thieme Verlag KG Stuttgart · New York.
DOT National Transportation Integrated Search
2017-10-25
The Task 8 D2X Hub Proof-of-Concept Test Evaluation Report provides results of the experimental data analysis performed in accordance with the experimental plan for the proof-of-concept version of the prototype system. The data set analyzed includes ...
A Microcomputer Program for Evaluating Pumping Test Results for Confined Aquifers.
ERIC Educational Resources Information Center
Smith, Stephen M.
1986-01-01
Describes an interactive, self-prompting BASIC program that can be incorporated in introductory and intermediate hydrology courses. Exlains how the program can be used to evaluate pumping test data and also to calculate transmissivity and storativity values of confined aquifers. The program is written for the IBM PC. (ML)
Ultrasonic test of resistance spot welds based on wavelet package analysis.
Liu, Jing; Xu, Guocheng; Gu, Xiaopeng; Zhou, Guanghao
2015-02-01
In this paper, ultrasonic test of spot welds for stainless steel sheets has been studied. It is indicated that traditional ultrasonic signal analysis in either time domain or frequency domain remains inadequate to evaluate the nugget diameter of spot welds. However, the method based on wavelet package analysis in time-frequency domain can easily distinguish the nugget from the corona bond by extracting high-frequency signals in different positions of spot welds, thereby quantitatively evaluating the nugget diameter. The results of ultrasonic test fit the actual measured value well. Mean value of normal distribution of error statistics is 0.00187, and the standard deviation is 0.1392. Furthermore, the quality of spot welds was evaluated, and it is showed ultrasonic nondestructive test based on wavelet packet analysis can be used to evaluate the quality of spot welds, and it is more reliable than single tensile destructive test. Copyright © 2014 Elsevier B.V. All rights reserved.
Battery testing at Argonne National Laboratory
NASA Astrophysics Data System (ADS)
Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.
1993-03-01
Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.
Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever
Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M
2017-01-01
Background Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. Objectives To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. Selection criteria We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). Data collection and analysis Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. Main results Thirty-seven studies met the inclusion criteria and included a total of 5080 participants (range 50 to 1732). Enteric fever prevalence rates in the study populations ranged from 1% to 75% (median prevalence 24%, interquartile range (IQR) 11% to 46%). The included studies evaluated 16 different RDTs, and 16 studies compared two or more different RDTs. Only three studies used the Grade 1 reference standard, and only 11 studies recruited unselected febrile patients. Most included studies were from Asia, with five studies from sub-Saharan Africa. All of the RDTs were designed to detect S.Typhi infection only. Most studies evaluated three RDTs and their variants: TUBEX in 14 studies; Typhidot (Typhidot, Typhidot-M, and TyphiRapid-Tr02) in 22 studies; and the Test-It Typhoid immunochromatographic lateral flow assay, and its earlier prototypes (dipstick, latex agglutination) developed by the Royal Tropical Institute, Amsterdam (KIT) in nine studies. Meta-analyses showed an average sensitivity of 78% (95% confidence interval (CI) 71% to 85%) and specificity of 87% (95% CI 82% to 91%) for TUBEX; and an average sensitivity of 69% (95% CI 59% to 78%) and specificity of 90% (95% CI 78% to 93%) for all Test-It Typhoid and prototype tests (KIT). Across all forms of the Typhidot test, the average sensitivity was 84% (95% CI 73% to 91%) and specificity was 79% (95% CI 70% to 87%). When we based the analysis on the 13 studies of the Typhidot test that either reported indeterminate test results or where the test format means there are no indeterminate results, the average sensitivity was 78% (95% CI 65% to 87%) and specificity was 77% (95% CI 66% to 86%). We did not identify any difference in either sensitivity or specificity between TUBEX, Typhidot, and Test-it Typhoid tests when based on comparison to the 13 Typhidot studies where indeterminate results are either reported or not applicable. If TUBEX and Test-it Typhoid are compared to all Typhidot studies, the sensitivity of Typhidot was higher than Test-it Typhoid (15% (95% CI 2% to 28%), but other comparisons did not show a difference at the 95% level of CIs. In a hypothetical cohort of 1000 patients presenting with fever where 30% (300 patients) have enteric fever, on average Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results will miss the diagnosis in 66 patients with enteric fever, TUBEX will miss 66, and Test-It Typhoid and prototype (KIT) tests will miss 93. In the 700 people without enteric fever, the number of people incorrectly diagnosed with enteric fever would be 161 with Typhidot tests, 91 with TUBEX, and 70 with Test-It Typhoid and prototype (KIT) tests. The CIs around these estimates were wide, with no difference in false positive results shown between tests. The quality of the data for each study was evaluated using a standardized checklist called QUADAS-2. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low. Authors' conclusions In 37 studies that evaluated the diagnostic accuracy of RDTs for enteric fever, few studies were at a low risk of bias. The three main RDT tests and variants had moderate diagnostic accuracy. There was no evidence of a difference between the average sensitivity and specificity of the three main RDT tests. More robust evaluations of alternative RDTs for enteric fever are needed. The accuracy of rapid diagnostic tests for detecting typhoid and paratyphoid (enteric) fever Cochrane researchers assessed the accuracy of commercially-available rapid diagnostic tests and their prototypes (including TUBEX, Typhidot, Typhidot-M, Test-it Typhoid, and other tests) for detecting typhoid and paratyphoid (enteric) fever in people living in countries where the estimated number of individuals with the disease at any one time is greater than 10 per 100,000 population. If accurate, they could replace the current World Health Organization (WHO)-recommended diagnostic test: culture (growing the bacteria that causes the infection from a patient’s blood or bone marrow). Background Typhoid fever and paratyphoid fever are infections caused by the bacteria Salmonella Typhi and Salmonella Paratyphi A respectively. The term ‘enteric fever’ is used to describe both infections. Enteric fever can be difficult to diagnose as the signs and symptoms are similar to those of other infectious diseases that cause fever such as malaria. The recommended test to confirm if a person has enteric fever is to grow the Salmonella from their blood. It takes at least 48 hours to give a result, so cannot help healthcare workers make a diagnosis the same day the blood culture is taken. Blood cultures may give a negative result even though a person has enteric fever. The test also requires a laboratory and trained staff, which are often unavailable in communities where enteric fever is common. Rapid diagnostic tests (RDTs) are designed to be easy to use, and to deliver a quick result without the need for a blood culture laboratory. The cost of an enteric fever RDT would be significantly less than a blood culture, and requires less training to perform. Study characteristics Cochrane researchers searched the available literature up to 4 March 2016 and included 37 studies. Most studies recruited participants from South Asia. Most participants were adults, with 22 studies including children. All of the RDTs evaluated detected Salmonella Typhi (typhoid fever) only. Quality of the evidence The Cochrane researchers evaluated the quality of the data for each study using a standardized checklist called QUADAS-2. High quality studies that compared different types of RDT in the same patients were few in number. Two-thirds of the included studies did not evaluate the RDTs in the context of patients who are typically tested for the disease. Many studies utilized a particular study design (a case control study) which risks overestimating RDT accuracy. In the studies evaluating the Typhidot RDT, it was often unclear how many test results were indeterminate, when the test cannot distinguish a current episode of infection from a previous disease episode. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low. Key results Sensitivity indicates the percentage of patients with a positive test result who are correctly diagnosed with disease. Specificity indicates the percentage of patients who are correctly identified as not having disease. TUBEX showed an average sensitivity of 78% and specificity of 87%. Typhidot studies, grouped together to include Typhidot, Typhidot-M, and TyphiRapid-Tr02, showed an average sensitivity of 84% and specificity of 79%. When Typhidot studies with clear reporting of indeterminate results are considered, the average sensitivity and specificity of Typhidot was 78% and 77% respectively. Test-It Typhoid and prototypes (KIT) showed an average sensitivity of 69% and specificity of 90%. Based on these results, in 1000 patients with fever where 30% (300 patients) have enteric fever, we would expect Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results to, on average, miss the diagnosis (give a false negative result) in 66 patients with enteric fever, TUBEX to miss 66, and Test-It Typhoid and prototypes (KIT) to miss 93. In the 700 people without enteric fever, the number of people incorrectly given a diagnosis of enteric fever (a false positive result) would be on average 161 with these Typhidot tests, 91 with TUBEX, and 70 with the Test-It Typhoid and prototypes (KIT). These differences in the number of false negative and false positive results in patients from the different tests are not statistically important. The RDTs evaluated are not sufficiently accurate to replace blood culture as a diagnostic test for enteric fever. PMID:28545155
[Auditory processing evaluation in children born preterm].
Gallo, Júlia; Dias, Karin Ziliotto; Pereira, Liliane Desgualdo; Azevedo, Marisa Frasson de; Sousa, Elaine Colombo
2011-01-01
To verify the performance of children born preterm on auditory processing evaluation, and to correlate the data with behavioral hearing assessment carried out at 12 months of age, comparing the results to those of auditory processing evaluation of children born full-term. Participants were 30 children with ages between 4 and 7 years, who were divided into two groups: Group 1 (children born preterm), and Group 2 (children born full-term). The auditory processing results of Group 1 were correlated to data obtained from the behavioral auditory evaluation carried out at 12 months of age. The results were compared between groups. Subjects in Group 1 presented at least one risk indicator for hearing loss at birth. In the behavioral auditory assessment carried out at 12 months of age, 38% of the children in Group 1 were at risk for central auditory processing deficits, and 93.75% presented auditory processing deficits on the evaluation. Significant differences were found between the groups for the temporal order test, the PSI test with ipsilateral competitive message, and the speech-in-noise test. The delay in sound localization ability was associated to temporal processing deficits. Children born preterm have worse performance in auditory processing evaluation than children born full-term. Delay in sound localization at 12 months is associated to deficits on the physiological mechanism of temporal processing in the auditory processing evaluation carried out between 4 and 7 years.
Crobach, M J T; Planche, T; Eckert, C; Barbut, F; Terveer, E M; Dekkers, O M; Wilcox, M H; Kuijper, E J
2016-08-01
In 2009 the first European Society of Clinical Microbiology and Infectious Diseases (ESCMID) guideline for diagnosing Clostridium difficile infection (CDI) was launched. Since then newer tests for diagnosing CDI have become available, especially nucleic acid amplification tests. The main objectives of this update of the guidance document are to summarize the currently available evidence concerning laboratory diagnosis of CDI and to formulate and revise recommendations to optimize CDI testing. This update is essential to improve the diagnosis of CDI and to improve uniformity in CDI diagnosis for surveillance purposes among Europe. An electronic search for literature concerning the laboratory diagnosis of CDI was performed. Studies evaluating a commercial laboratory test compared to a reference test were also included in a meta-analysis. The commercial tests that were evaluated included enzyme immunoassays (EIAs) detecting glutamate dehydrogenase, EIAs detecting toxins A and B and nucleic acid amplification tests. Recommendations were formulated by an executive committee, and the strength of recommendations and quality of evidence were graded using the Grades of Recommendation Assessment, Development and Evaluation (GRADE) system. No single commercial test can be used as a stand-alone test for diagnosing CDI as a result of inadequate positive predictive values at low CDI prevalence. Therefore, the use of a two-step algorithm is recommended. Samples without free toxin detected by toxins A and B EIA but with positive glutamate dehydrogenase EIA, nucleic acid amplification test or toxigenic culture results need clinical evaluation to discern CDI from asymptomatic carriage. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Tsouras, Theo
2017-01-01
This study aimed to evaluate a recently developed equipment test method by assessing the safe and accurate functioning of the Abbott Optium FreeStyle H portable blood glucose monitor for use in the Alfred Hospital's hyperbaric chamber. The results of this study indicate that the test method can be used successfully to evaluate instruments and/or devices for use in the hyperbaric environment. The evaluation initially found that this particular glucose monitor contained a lithium battery which can be hazardous when used in the hyperbaric environment. However, upon further inspection it was determined the battery posed minimal risk for fire and explosion due to its small capacity and design application. The results indicate that the Abbott Optium FreeStyle H blood glucose monitor operated normally when used in the hyperbaric chamber. This glucometer was found to perform within the calibration specification requirements for accuracy at all stages of a typical hyperbaric treatment and as such the Abbott Optium FreeStyle H blood glucose monitor was deemed safe for use in the hyperbaric chamber at the Alfred Hospital. Copyright© Undersea and Hyperbaric Medical Society.
Mezzalira, Raquel; Bittar, Roseli Saraiva Moreira; do Carmo Bilécki-Stipsky, Marcia Maria; Brugnera, Cibele; Grasel, Signe Schuster
2017-08-01
This study compared the results of the caloric test with those of the video head impulse test obtained during the same session and evaluated whether the former can be used to screen for non-acute vestibular dysfunction. A total of 157 participants complaining of dizziness with vestibular characteristics of varying durations and clinical courses completed the caloric test and video head impulse test. Significantly more caloric test results than video head impulse test results were abnormal. The results of the caloric test and video head impulse test are distinct but complement each other. Within our sample, the caloric test was more sensitive for vestibular dysfunction. Therefore, the video head impulse test is not a suitable screening tool of the vestibular system in patients with chronic complaints.
NASA Technical Reports Server (NTRS)
Garcia, Daniel B.; Forman, Royce; Shindo, David
2010-01-01
A test program was developed and executed to evaluate the influence of corroded hemispherical notches on the fatigue crack initiation and propagation in aluminum 7075-T7351, 4340 steel, and D6AC steel. Surface enhancements such as shot peening and laser shock peening were also incorporated as part of the test effort with the intent of improving fatigue performance. In addition to the testing, fracture mechanics and endurance limit based analysis methods were evaluated to characterize the results with the objective of challenging typical assumptions used in modeling fatigue cracks from corrosion pits. The results specifically demonstrate that the aluminum and steel alloys behave differently with respect to fatigue crack initiation from hemispherical corrosion pits. The aluminum test results were bounded by the fracture mechanics and endurance limit models while exhibiting a general insensitivity to the residual stress field generated by shot peening. The steel specimens were better characterized by the endurance limit fatigue properties and did exhibit sensitivities to residual stresses from the shot peening and laser shock peening
Applications of flight control system methods to an advanced combat rotorcraft
NASA Technical Reports Server (NTRS)
Tischler, Mark B.; Fletcher, Jay W.; Morris, Patrick M.; Tucker, George T.
1989-01-01
Advanced flight control system design, analysis, and testing methodologies developed at the Ames Research Center are applied in an analytical and flight test evaluation of the Advanced Digital Optical Control System (ADOCS) demonstrator. The primary objectives are to describe the knowledge gained about the implications of digital flight control system design for rotorcraft, and to illustrate the analysis of the resulting handling-qualities in the context of the proposed new handling-qualities specification for rotorcraft. Topics covered in-depth are digital flight control design and analysis methods, flight testing techniques, ADOCS handling-qualities evaluation results, and correlation of flight test results with analytical models and the proposed handling-qualities specification. The evaluation of the ADOCS demonstrator indicates desirable response characteristics based on equivalent damping and frequency, but undersirably large effective time-delays (exceeding 240 m sec in all axes). Piloted handling-qualities are found to be desirable or adequate for all low, medium, and high pilot gain tasks; but handling-qualities are inadequate for ultra-high gain tasks such as slope and running landings.
Nickel hydrogen battery cell storage matrix test
NASA Technical Reports Server (NTRS)
Wheeler, James R.; Dodson, Gary W.
1993-01-01
Test were conducted to evaluate post storage performance of nickel hydrogen cells with various design variables, the most significant being nickel precharge versus hydrogen precharge. Test procedures and results are presented in outline and graphic form.
Andrade, Adriana Neves de; Silva, Mariane Richetto da; Iorio, Maria Cecilia Martinelli; Gil, Daniela
2015-01-01
To compare the performance of the Dichotic Sentence Identification (DSI) test in the Brazilian Portuguese version, considering: the right and left ears and the educational status in normal-hearing individuals. This investigation assessed 200 individuals who are normal listeners and right-handed and were divided into seven groups according to the years of schooling. All the participants underwent basic audiologic evaluation and behavioral auditory processing assessment (sound localization test, memory test for verbal and nonverbal sounds in sequence, dichotic digits test, and DSI). The evaluated individuals revealed an average educational status of 13.1 years and results within normal limits in the selected tests for the audiologic and auditory processing assessments. Regarding the DSI test, the educational status showed a dependent relationship with the percentages of correct answers in each stage of the test and the evaluated ear. There was a statistically significant positive correlation between the educational status and the percentage of correct answers for all the stages of the DSI test in both the ears. There was also an effect of the educational level on the results obtained in each condition of the DSI test, with the exception of directed attention to the right ear. Comparing the performance considering the variables studied in the DSI test, we concluded that there is an advantage of the right ear and that, the better the educational level, the better the performance of the individuals.
Evaluating School Facilities in Brazil
ERIC Educational Resources Information Center
Ornstein, Sheila Walbe; Moreira, Nanci Saraiva
2008-01-01
Brazil's Sao Paulo Metropolitan Region is conducting a performance evaluation pilot study at three schools serving disadvantaged populations. The objective is first to test methods which can facilitate Post Occupancy Evaluations (POEs) and then to carry out the evaluations. The preliminary results are provided below.
Iqbal, H. Syed; Solomon, Suniti; Murugavel, K. G.; Solomon, Sunil Suhas; Balakrishnan, P.
2005-01-01
Diagnosis of human immunodeficiency virus (HIV) infection is important for patient management and prevention of new infections. The number of test kits available for the detection of HIV antibodies is unprecedented. In order to identify appropriate test kits, we evaluated a variety of commercial kits manufactured abroad as well as in India. The plasma and serum specimens (n = 264) were collected from individuals attending the Voluntary Counseling and Testing Centre at the YRG Centre for AIDS and Education. The specimens were used to evaluate six commercially available HIV test kits: Enzaids HIV 1+2, HIV-CheX, Murex HIV-1.2.0, Genscreen HIV 1/2 version 2, Vironostika HIV Uni-Form II Ag/Ab, and CombAids RS Advantage. High sensitivities and specificities (≥99%) were observed for the Enzaids, Murex, Vironostika, and CombAids assays. HIV-CheX showed the highest number of false-positive and false-negative results. The Genscreen test also gave many false positives. The study indicated that the Enzaids, Murex, and Vironostika enzyme-linked immunosorbent assay kits and the CombAids RS Advantage rapid assay could be used to achieve acceptable results for the detection of HIV antibodies. A combination of two tests is recommended to optimize the efficiency of HIV antibody testing algorithms, especially when evaluation with an HIV Western blot confirmatory test is not possible. PMID:16339066
Mobile propeller dynamometer validation
NASA Astrophysics Data System (ADS)
Morris, Mason Wade
With growing interest in UAVs and OSU's interest in propeller performance and manufacturing, evaluating UAV propeller and propulsion system performance has become essential. In attempts to evaluate these propellers a mobile propeller dynamometer has been designed, built, and tested. The mobile dyno has been designed to be cost effective through the ability to load it into the back of a test vehicle to create simulated forward flight characteristics. This allows much larger propellers to be dynamically tested without the use of large and expensive wind tunnels. While evaluating the accuracy of the dyno, several improvements had to be made to get accurate results. The decisions made to design and improve the mobile propeller dyno will be discussed along with attempts to validate the dyno by comparing its results against known sources. Another large part of assuring the accuracy of the mobile dyno is determining if the test vehicle will influence the flow going into the propellers being tested. The flow into the propeller needs to be as smooth and uniform as possible. This is determined by characterizing the boundary layer and accelerated flow over the vehicle. This evaluation was accomplished with extensive vehicle aerodynamic measurements with the use of full-scale tests using a pitot-rake and the actual test vehicle. Additional tests were conducted in Oklahoma State University's low speed wind tunnel with a 1/8-scale model using qualitative flow visualization with smoke. Continuing research on the mobile dyno will be discussed, along with other potential uses for the dyno.
Schulze, P.A.; Capel, P.D.; Squillace, P.J.; Helsel, D.R.
1993-01-01
The usefulness and sensitivity, of a portable immunoassay test for the semiquantitative field screening of water samples was evaluated by means of laboratory and field studies. Laboratory results indicated that the tests were useful for the determination of atrazine concentrations of 0.1 to 1.5 μg/L. At a concentration of 1 μg/L, the relative standard deviation in the difference between the regression line and the actual result was about 40 percent. The immunoassay was less sensitive and produced similar errors for other triazine herbicides. After standardization, the test results were relatively insensitive to ionic content and variations in pH (range, 4 to 10), mildly sensitive to temperature changes, and quite sensitive to the timing of the final incubation step, variances in timing can be a significant source of error. Almost all of the immunoassays predicted a higher atrazine concentration in water samples when compared to results of gas chromatography. If these tests are used as a semiquantitative screening tool, this tendency for overprediction does not diminish the tests' usefulness. Generally, the tests seem to be a valuable method for screening water samples for triazine herbicides.
Evaluation of new aquatic toxicity test methods for oil dispersants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pace, C.B.; Clark, J.R.; Bragin, G.E.
1994-12-31
Current aquatic toxicity test methods used for dispersant registration do not address real world exposure scenarios. Current test methods require 48 or 96 hour constant exposure conditions. In contrast, environmentally realistic exposures can be described as a pulse in which the initial concentration declines over time. Recent research using a specially designed testing apparatus (the California system) has demonstrated that exposure to Corexit 9527{reg_sign} under pulsed exposure conditions may be 3 to 22 times less toxic compared to continuous exposure scenarios. The objectives of this study were to compare results of toxicity tests using the California test system to resultsmore » from standardized tests, evaluate sensitivity of regional (Holmesimysis cast and Atherinops affinis) vs. standard test species (Mysidopsis bahia and Menidia beryllina) and determine if tests using the California test system and method are reproducible. All tests were conducted using Corexit 9527{reg_sign} as the test material. Standard toxicity tests conducted with M. bahia and H. cast resulted in LC50s similar to those from tests using the California apparatus. LC50s from tests conducted in the authors` laboratory with the California system and standard test species were within a factor of 2 to 6 of data previously reported for west coast species. Results of tests conducted with H. cast in the laboratory compared favorably to data reported by Singer et al. 1991.« less
Evaluation of four slide test kits for the detection of human chorionic gonadotropin in urine
Dietrich, Michael; French, J. A.
1974-01-01
Three “indirect-type” slide tests utilizing the principle of hemagglutination inhibition and one new “direct-type” slide test employing direct agglutination were evaluated for their sensitivity in detecting human chorionic gonadotropin (HCG) in urine. The results of positive tests in a group of woman in very early pregnancy were correlated with the “days after last menses”. In this series the direct slide test was the most accurate. A control must be used with each direct test to indicate interfering substances and when such are present a different test must be used. All tests were found to be of the relative sensitivity stated by the manufacturer. PMID:4851924
Impact of environmental adaptation on tear film assessments.
Fagehi, R
2018-03-01
The purpose of this study was to investigate the effect of ocular environmental adaptation on clinical tear film assessment. Thirty subjects (male, mean age 23±2.5) participated in this study. A number of clinical tear film tests were applied, including: fluorescein tear break-up time (FTBUT), Schirmer test and tear prism height test (TPH). The tear physiology of each subject was evaluated twice, once immediately when they arrived from the external environment, and then after 30minutes adaptation in the exam room environment. The mean values were: Schirmer test A (22.1±2.99), Schirmer test B (24.2±2.63), FTBUT A (8.00±1.94), FTBUT B (9.13±2.04), TPH A (0.179±0.026) and TPH B* (0.187±0.023). Statistical testing using Wilcoxon-signed rank test showed a significant difference between the Schirmer test results measured at the different times (P=0.008). Also, the FTBUT and tear prism height test results showed significant differences between the two evaluation times, (P=0.001, 0.011, respectively) (A: tear assessed when the subject comes from the outside environment, B: tear film assessed after 30min adaptation in the clinical environment). This study showed a significant difference between the tear film test results evaluated when the subjects were assessed immediately from the outside environment and after an adaptation time in the clinic environment. Practitioners must consider the effect of differences between external and clinical environment adaptation on clinical tear film physiology. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Romero, Tamara; Beltrán, María Carmen; Althaus, Rafael Lisandro; Molina, María Pilar
2014-08-01
The aim of the study was to evaluate the interference of acid and alkaline detergents employed in the cleaning of milking equipment of caprine dairy farms on the performance of microbial tests used in antibiotic control (BRT MRL, Delvotest MCS, and Eclipse 100). Eight concentrations of commercial detergents, five acid (0-0.25%) and five alkaline (0-1%) were add to antimicrobial-free goat's milk to evaluate the detergent effect on the response of microbial inhibitor tests. To evaluate the effect of detergents on the detection capability of microbial tests two detergents at 0.5 ml/l (one acid and one basic) and eight concentrations of four β-lactam antibiotics (ampicillin, amoxicillin, cloxacillin and benzylpenicillin) were used. Milk without detergents was used as control. The spiked samples were analysed twelve times by three microbial tests. The results showed that the presence of acid detergents did not affect the response of microbial tests for any of the concentrations tested. However, at concentrations equal to or greater than 2 ml/l alkaline detergents positive results were found in microbial tests (16.7-100%). The detection limits of the screening tests for penicillins were not modified substantially by the presence of detergents. In general, the presence of acid and alkaline detergents in goat's milk did not produce a great interference in the microbial tests, only high concentrations of detergents could cause non-compliant results, but these concentrations are difficult to find in practice if proper cleaning procedures are applied in goat dairy farms.
ERIC Educational Resources Information Center
Olsen, Robert B.; Unlu, Fatih; Price, Cristofer; Jaciw, Andrew P.
2011-01-01
This report examines the differences in impact estimates and standard errors that arise when these are derived using state achievement tests only (as pre-tests and post-tests), study-administered tests only, or some combination of state- and study-administered tests. State tests may yield different evaluation results relative to a test that is…
ATS-5 12 year in orbit evaluation
NASA Technical Reports Server (NTRS)
Kissel, F. J.; Schaffer, J.
1981-01-01
The results of the ATS 5 End-of-Life (EOL) tests are presented. Whenever possible, the test data were compared with prelaunch and inflight data. Pertinent memos and other informal documents containing these data are included as appendixes. The EOL tests include communication subsystems tests, power sybsystem tests, and gravity gradient television camera system tests.
NASA Technical Reports Server (NTRS)
Polotzky, Anthony S.; Wieseman, Carol; Hoadley, Sherwood Tiffany; Mukhopadhyay, Vivek
1990-01-01
The development of a controller performance evaluation (CPE) methodology for multiinput/multioutput digital control systems is described. The equations used to obtain the open-loop plant, controller transfer matrices, and return-difference matrices are given. Results of applying the CPE methodology to evaluate MIMO digital flutter suppression systems being tested on an active flexible wing wind-tunnel model are presented to demonstrate the CPE capability.
NASA Technical Reports Server (NTRS)
Hodgson, Edward; Oehler, William; Dionne, Steve; Converse, David; Jennings, Mallory A.
2012-01-01
NASA s plans for Extravehicular Activity (EVA) portable life support systems for future exploration missions result in different design requirements than those which led to the combined fan / pump / separator in the current ISS Extravehicular Mobility Unit (EMU). To meet these new requirements, NASA contracted with Hamilton Sundstrand to provide two new prototype fans designed to meet anticipated future system requirements. Based on design trade studies, a high speed fan with mechanical bearing support of the rotating elements and a novel non-metallic barrier canned motor design was developed and implemented in the deliverable prototypes. The prototypes, which used two different bearing lubricants, have been extensively tested in both stand-alone and integrated system tests in NASA laboratories and proven to meet the anticipated performance requirements. Subsequently, they have been subjected to post test inspection and analysis in Hamilton Sundstrand laboratories to assess the effects of integrated operation and resultant exposure to vent loop contaminants. Results have confirmed expectations that one of the lubricants would be superior in this application and the prototype fans have been reassembled with new bearings with the superior lubricant. They have now been returned to the Johnson Space Center for further testing and maturation as part of NASA s PLSS 2.0 integrated test effort. This paper will discuss the test history of these units, resulting test data, the results of post test evaluation, and plans for further testing in the near future.
ERIC Educational Resources Information Center
de la Torre, Jimmy; Lee, Young-Sun
2013-01-01
This article used the Wald test to evaluate the item-level fit of a saturated cognitive diagnosis model (CDM) relative to the fits of the reduced models it subsumes. A simulation study was carried out to examine the Type I error and power of the Wald test in the context of the G-DINA model. Results show that when the sample size is small and a…
DOT National Transportation Integrated Search
1976-09-01
Results of aeronautical L-band multipath channel characterization tests are given. All tests were conducted between September 1974 and April 1975 as part of the U.S. DOT aeronautical technology test program. These tests were part of the international...
Performance, Cognition, and Physiological Responding in Test Anxiety.
ERIC Educational Resources Information Center
Holroyd, Kenneth A.; And Others
1978-01-01
This research was designed to clarify the role of autonomic response and evaluative self-awareness in test anxiety. Autonomic, self-report, and performance measures of anxiety were collected from both test-anxious and non-test-anxious individuals in an analogue testing situation under three experimental conditions. Results support cognitive…
Permanent and separable aerospace tubing/ fitting evaluation program, volume 1
NASA Technical Reports Server (NTRS)
Ursell, C. R.; Franz, C. R.
1975-01-01
The tube fitting evaluation program was conducted to develop a standard overall test program including methods, procedures, and equipment as well as recommended test sequences for qualifying fitting/tubing assemblies. The program consisted of testing the MS flareless (separable) fitting and utilizing the results as baseline data from which all other fittings will be evaluated. Five separable designs and five permanent designs were tested in three sizes with two types of tubing materials. The basic design requirements were 4,000 psi operating pressure within the temperature range of minus 65 F to plus 450 F while also being compatible with 21-6-9 and titanium 3Al-2.5V tubing alloys.
Runway Incursion Prevention System Simulation Evaluation
NASA Technical Reports Server (NTRS)
Jones, Denise R.
2002-01-01
A Runway Incursion Prevention System (RIPS) was evaluated in a full mission simulation study at the NASA Langley Research center in March 2002. RIPS integrates airborne and ground-based technologies to provide (1) enhanced surface situational awareness to avoid blunders and (2) alerts of runway conflicts in order to prevent runway incidents while also improving operational capability. A series of test runs was conducted in a high fidelity simulator. The purpose of the study was to evaluate the RIPS airborne incursion detection algorithms and associated alerting and airport surface display concepts. Eight commercial airline crews participated as test subjects completing 467 test runs. This paper gives an overview of the RIPS, simulation study, and test results.
Seelye, James G.; Mac, Michael J.
1984-01-01
A literature review of sediment bioassessment was conducted as the first step in the development of a more standardized and ecologically sound test procedure for evaluating sediment quality. Based on the review, the authors concluded that 1) a standardized laboratory bioassessment test should consist of flowthrough exposure of at least 10 days duration using more than one aquatic organism including at least an infaunal benthic invertebrate and a fish species. 2) Before adoption of a laboratory sediment bioassessment procedure, the laboratory results should be evaluated by comparison with field conditions. 3) Most current sediment bioassessment regulatory tests measure acute toxicity or bioaccumulation. Development of tests to evaluate chronic, sublethal effects is needed.
Using a fuzzy comprehensive evaluation method to determine product usability: A test case
Zhou, Ronggang; Chan, Alan H. S.
2016-01-01
BACKGROUND: In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. OBJECTIVE AND METHODS: In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. RESULTS AND CONCLUSIONS: This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method. PMID:28035942
Evaluation of Fire Test Methods for Aircraft Thermal Acoustical Insulation
DOT National Transportation Integrated Search
1997-09-01
This report presents the results of laboratory round robin flammability testing performed on thermal acoustical insulation blankets and the films used as insulation coverings. This work was requested by the aircraft industry as a result of actual inc...
Commercial Off-The-Shelf (COTS) Graphics Processing Board (GPB) Radiation Test Evaluation Report
NASA Technical Reports Server (NTRS)
Salazar, George A.; Steele, Glen F.
2013-01-01
Large round trip communications latency for deep space missions will require more onboard computational capabilities to enable the space vehicle to undertake many tasks that have traditionally been ground-based, mission control responsibilities. As a result, visual display graphics will be required to provide simpler vehicle situational awareness through graphical representations, as well as provide capabilities never before done in a space mission, such as augmented reality for in-flight maintenance or Telepresence activities. These capabilities will require graphics processors and associated support electronic components for high computational graphics processing. In an effort to understand the performance of commercial graphics card electronics operating in the expected radiation environment, a preliminary test was performed on five commercial offthe- shelf (COTS) graphics cards. This paper discusses the preliminary evaluation test results of five COTS graphics processing cards tested to the International Space Station (ISS) low earth orbit radiation environment. Three of the five graphics cards were tested to a total dose of 6000 rads (Si). The test articles, test configuration, preliminary results, and recommendations are discussed.
Evaluation of Four Bedside Test Systems for Card Performance, Handling and Safety.
Giebel, Felix; Picker, Susanne M; Gathof, Birgit S
2008-01-01
SUMMARY: OBJECTIVE: Pretransfusion ABO compatibility testing is a simple and required precaution against ABO-incompatible transfusion, which is one of the greatest threats in transfusion medicine. While distinct agglutination is most important for correct test interpretation, protection against infectious diseases and ease of handling are crucial for accurate test performance. Therefore, the aim of this study was to evaluate differences in test card design, handling, and user safety. DESIGN: Four different bedside test cards with pre-applied antibodies were evaluated by 100 medical students using packed red blood cells of different ABO blood groups. Criteria of evaluation were: agglutination, labelling, handling, and safety regarding possible user injuries. Criteria were rated subjectively according to German school notes ranging from 1 = very good to 6 = very bad/insufficient. RESULTS: Overall, all cards received very good/good marks. The ABO blood group was identified correctly in all cases. Three cards (no. 1, no. 3, no. 4) received statistically significant (p < 0.008) prominence (mean values shown) concerning clearness of agglutination (1.7-1.9 vs. 2.4 for no. 2). Systems with dried antibodies (no. 2, no. 4) outmatched the other systems with respect to overall test system performance (2.0 vs. 2.8-2.9), labelling (1.5 vs. 2.2-2.4), handling (1.9-2.0 vs. 2.5), and user safety (2.5 vs. 3.4). Analysis of card self-explanation revealed no remarkable differences. CONCLUSION: Despite good performance of all card systems tested, the best results when including all criteria evaluated were obtained with card no. 4 (particularly concerning clear agglutination), followed by cards no. 2, no. 1, and no. 3.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-01-01
This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
Comparison of test protocols for standard room/corner tests
R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens
1998-01-01
As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...
Cody, John T
2002-05-01
Medical Review Officer interpretation of laboratory results is an important component of drug testing programs. The clinical evaluation of laboratory results to assess the possibility of appropriate medical use of a drug is a task with many different facets, depending on the drug class considered. This intercession prevents the reporting of positive results unless it is apparent that drugs were used illicitly. In addition to the commonly encountered prescribed drugs that yield positive drug testing results, other sources of positive results must be considered. This review describes a series of compounds referred to as "precursor" drugs that are metabolized by the body to amphetamine and/or methamphetamine. These compounds lead to positive results for amphetamines even though neither amphetamine nor methamphetamine were used, a possibility that must be considered in the review of laboratory results. Description of the drugs, their clinical indications, and results seen following administration are provided. This information allows for the informed evaluation of results with regard to the potential involvement of these drugs.
Design and evaluation of experimental ceramic automobile thermal reactors
NASA Technical Reports Server (NTRS)
Stone, P. L.; Blankenship, C. P.
1974-01-01
The paper summarizes the results obtained in an exploratory evaluation of ceramics for automobile thermal reactors. Candidate ceramic materials were evaluated in several reactor designs using both engine dynamometer and vehicle road tests. Silicon carbide contained in a corrugated metal support structure exhibited the best performance, lasting 1100 hours in engine dynamometer tests and for more than 38,600 kilimeters (24,000 miles) in vehicle road tests. Although reactors containing glass-ceramic components did not perform as well as silicon carbide, the glass-ceramics still offer good potential for reactor use with improved reactor designs.
Design and evaluation of experimental ceramic automobile thermal reactors
NASA Technical Reports Server (NTRS)
Stone, P. L.; Blankenship, C. P.
1974-01-01
The results obtained in an exploratory evaluation of ceramics for automobile thermal reactors are summarized. Candidate ceramic materials were evaluated in several reactor designs by using both engine-dynamometer and vehicle road tests. Silicon carbide contained in a corrugated-metal support structure exhibited the best performance, lasting 1100 hr in engine-dynamometer tests and more than 38,600 km (24000 miles) in vehicle road tests. Although reactors containing glass-ceramic components did not perform as well as those containing silicon carbide, the glass-ceramics still offer good potential for reactor use with improved reactor designs.
Electronics systems test laboratory testing of shuttle communications systems
NASA Technical Reports Server (NTRS)
Stoker, C. J.; Bromley, L. K.
1985-01-01
Shuttle communications and tracking systems space to space and space to ground compatibility and performance evaluations are conducted in the NASA Johnson Space Center Electronics Systems Test Laboratory (ESTL). This evaluation is accomplished through systems verification/certification tests using orbiter communications hardware in conjunction with other shuttle communications and tracking external elements to evaluate end to end system compatibility and to verify/certify that overall system performance meets program requirements before manned flight usage. In this role, the ESTL serves as a multielement major ground test facility. The ESTL capability and program concept are discussed. The system test philosophy for the complex communications channels is described in terms of the major phases. Results of space to space and space to ground systems tests are presented. Several examples of the ESTL's unique capabilities to locate and help resolve potential problems are discussed in detail.
Counter unmanned aerial system testing and evaluation methodology
NASA Astrophysics Data System (ADS)
Kouhestani, C.; Woo, B.; Birch, G.
2017-05-01
Unmanned aerial systems (UAS) are increasing in flight times, ease of use, and payload sizes. Detection, classification, tracking, and neutralization of UAS is a necessary capability for infrastructure and facility protection. We discuss test and evaluation methodology developed at Sandia National Laboratories to establish a consistent, defendable, and unbiased means for evaluating counter unmanned aerial system (CUAS) technologies. The test approach described identifies test strategies, performance metrics, UAS types tested, key variables, and the necessary data analysis to accurately quantify the capabilities of CUAS technologies. The tests conducted, as defined by this approach, will allow for the determination of quantifiable limitations, strengths, and weaknesses in terms of detection, tracking, classification, and neutralization. Communicating the results of this testing in such a manner informs decisions by government sponsors and stakeholders that can be used to guide future investments and inform procurement, deployment, and advancement of such systems into their specific venues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-02-01
This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
Piwowar, Valentina; Thiel, Felicitas
2014-10-01
Response shift (RS) can threaten the internal validity of pre-post designs. As RS may indicate a redefinition of the target construct, its occurrence in training evaluation is rather likely. The most common approach to deal with RS is to implement a retrospective pretest (then-test) instead of the traditional pre-test. In health psychology, an adapted measurement invariance approach (MIad) was developed as an alternative technique to study RS. Results produced by identifying RS with the two approaches were rarely studied simultaneously or within an experimental framework. To study RS in two different treatment conditions and compare results produced by both techniques in identifying various types of RS. We further studied validity aspects of the then-test. We evaluated RS by applying the then-test procedure (TP) and the measurement invariance apporach MIad within an experimental design: Participants either attended a short-term or a long-term classroom management training program. Participants were 146 student teachers in their first year of master's study. Pre (before training), post, and then self-ratings (after training) on classroom management knowledge were administered. Results indicated that the two approaches do not yield the same results. The MIad identified more and also group-specific RS as opposed to the findings of the TP, which found less and only little evidence for group-specific RS. Further research is needed to study the usability and validity of the respective approaches. In particular, the usability of the then-test seems to be challenged. © The Author(s) 2014.
Hercules Aerospace flywheel test results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steele, R.S. Jr.; Babelay, E.F. Jr.; Sutton, B.J.
1981-06-01
The detailed results of the spin test evaluation of the Hercules Aerospace flywheel at the Oak Ridge Flywheel Evaluation Laboratory (ORFEL) are presented. Details of the static evaluation with radiography and measures of weight, inertia, and natural frequencies are included. The flywheel was spun four times with the maximum speed being increased with each run. During the final run, the flywheel achieved 372 rps and stored 0.714 kWhr of kinetic energy at 37 Whr/kg. The ultimate speed was limited by a composite transverse strength that was somewhat lower than that used in the design of the flywheel. This resulted inmore » internal cracking of the flywheel and, eventually, the loss of material from the outer circumference.« less
NASA Technical Reports Server (NTRS)
1979-01-01
Tests, test results, examination and evaluation by Underwriters Laboratory, Inc., of a single family solar heating and hot water system consisting of collector, storage, control, transport, and data acquisition are presented. The structural characteristics of the solar flat plate collectors were evaluated according to snow and wind loads indicated in various building codes to determine their suitability for use both Michigan and Pennsylvania where prototype systems were installed. The flame spread classification of the thermal insulation is discussed and the fire tests conducted on components are described. The operation and dielectrics withstand tests of the energy transport module indicate the module is capable of rated air delivery. Tests of the control panel indicate the relay coil temperatures exceed the temperature limits allowed for the insulating materials involved.
Fire Safety Tests for Cesium-Loaded Spherical Resorcinol Formaldehyde Resin: Data Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Dong-Sang; Schweiger, Michael J.; Peterson, Reid A.
2012-09-01
A draft safety evaluation of the scenario for spherical resorcinol formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI) through a subcontract managed by Pacific Northwest National Laboratory (PNNL). The results of initial fire safety tests on themore » SRF resin were documented in a previous report (WTP-RPT-218). The present report summarizes the results of additional tests performed by SwRI on the cesium-loaded SRF resin. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. The as-received SwRI report is attached to this report in the Appendix A. Where applicable, the precision and bias of each test method, as given by each American Society for Testing and Materials (ASTM) standard procedure, are included and compared with the SwRI test results of the cesium-loaded SRF resin.« less
MAC Europe 1991 campaign: AIRSAR/AVIRIS data integration for agricultural test site classification
NASA Technical Reports Server (NTRS)
Sangiovanni, S.; Buongiorno, M. F.; Ferrarini, M.; Fiumara, A.
1993-01-01
During summer 1991, multi-sensor data were acquired over the Italian test site 'Otrepo Pavese', an agricultural flat area in Northern Italy. This area has been the Telespazio pilot test site for experimental activities related to agriculture applications. The aim of the investigation described in the following paper is to assess the amount of information contained in the AIRSAR (Airborne Synthetic Aperture Radar) and AVIRIS (Airborne Visible/Infrared Imaging Spectrometer) data, and to evaluate classification results obtained from each sensor data separately and from the combined dataset. All classifications are examined by means of the resulting confusion matrices and Khat coefficients. Improvements of the classification results obtained by using the integrated dataset are finally evaluated.
Next-generation avionics packaging and cooling 'test results from a prototype system'
NASA Astrophysics Data System (ADS)
Seals, J. D.
The author reports on the design, material characteristics, and test results obtained under the US Air Force's advanced aircraft avionics packaging technologies (AAAPT) program, whose charter is to investigate new designs and technologies for reliable packaging, interconnection, and thermal management. Under this program, AT&T Bell Laboratories has completed the preliminary testing of and is evaluating a number of promising materials and technologies, including conformal encapsulation, liquid flow-through cooling, and a cyanate ester backplane. A fifty-two module system incorporating these and and other technologies has undergone preliminary cooling efficiency, shock, sine and random vibration, and maintenance testing. One of the primary objectives was to evaluate the interaction compatibility of new materials and designs with other components in the system.
Development Status of Low-Shock Payload Separation Mechanism for H-IIA Launch Vehicle
NASA Astrophysics Data System (ADS)
Terashima, Keita; Kamita, Toru; Horie, Youichi; Kobayashi, Masakazu; Onikura, Hiroki
2013-09-01
This paper presents the design, analysis and test results of the low-shock payload separation mechanism for the H-IIA launch vehicle. The mechanism is based on a simple and reliable four-bar linkage, which makes the release speed of the marman clamp band tension lower than the current system.The adequacy of the principle for low-shock mechanism was evaluated by some simulations and results of fundamental tests. Then, we established the reliability design model of this mechanism, and the adequacy of this model was evaluated by elemental tests.Finally, we conducted the system separation tests using the payload adapter to which the mechanism was assembled, to confirm that the actual separation shock level satisfied our target.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
DOT National Transportation Integrated Search
1982-01-01
The report describes the results of the load tests and summarizes the collection of data on the dimensional changes and moisture content of the press-lain members and the number and types of vehicles using the bridge. The results of the load tests su...
Tree Testing of Hierarchical Menu Structures for Health Applications
Le, Thai; Chaudhuri, Shomir; Chung, Jane; Thompson, Hilaire J; Demiris, George
2014-01-01
To address the need for greater evidence-based evaluation of Health Information Technology (HIT) systems we introduce a method of usability testing termed tree testing. In a tree test, participants are presented with an abstract hierarchical tree of the system taxonomy and asked to navigate through the tree in completing representative tasks. We apply tree testing to a commercially available health application, demonstrating a use case and providing a comparison with more traditional in-person usability testing methods. Online tree tests (N=54) and in-person usability tests (N=15) were conducted from August to September 2013. Tree testing provided a method to quantitatively evaluate the information structure of a system using various navigational metrics including completion time, task accuracy, and path length. The results of the analyses compared favorably to the results seen from the traditional usability test. Tree testing provides a flexible, evidence-based approach for researchers to evaluate the information structure of HITs. In addition, remote tree testing provides a quick, flexible, and high volume method of acquiring feedback in a structured format that allows for quantitative comparisons. With the diverse nature and often large quantities of health information available, addressing issues of terminology and concept classifications during the early development process of a health information system will improve navigation through the system and save future resources. Tree testing is a usability method that can be used to quickly and easily assess information hierarchy of health information systems. PMID:24582924
ERIC Educational Resources Information Center
Londeree, Ben R.
1981-01-01
Postural deviations resulting from strength and flexibility imbalances include swayback, scoliosis, and rounded shoulders. Screening tests are one method for identifying strength problems. Tests for the evaluation of postural problems are described, and exercises are presented for the strengthening of muscles. (JN)
A Statistical Approach to Establishing Subsystem Environmental Test Specifications
NASA Technical Reports Server (NTRS)
Keegan, W. B.
1974-01-01
Results are presented of a research task to evaluate structural responses at various subsystem mounting locations during spacecraft level test exposures to the environments of mechanical shock, acoustic noise, and random vibration. This statistical evaluation is presented in the form of recommended subsystem test specifications for these three environments as normalized to a reference set of spacecraft test levels and are thus suitable for extrapolation to a set of different spacecraft test levels. The recommendations are dependent upon a subsystem's mounting location in a spacecraft, and information is presented on how to determine this mounting zone for a given subsystem.
CRT image recording evaluation
NASA Technical Reports Server (NTRS)
1971-01-01
Performance capabilities and limitations of a fiber optic coupled line scan CRT image recording system were investigated. The test program evaluated the following components: (1). P31 phosphor CRT with EMA faceplate; (2). P31 phosphor CRT with clear clad faceplate; (3). Type 7743 semi-gloss dry process positive print paper; (4). Type 777 flat finish dry process positive print paper; (5). Type 7842 dry process positive film; and (6). Type 1971 semi-gloss wet process positive print paper. Detailed test procedures used in each test are provided along with a description of each test, the test data, and an analysis of the results.
1986-12-01
PREDICTION VIA FIBER BUNDLE TESTING-EVALUATION OF TESTING EQUIPMENT JD DATA ACQUISITION SYSTEM PERSONAL AUTHOR(S) Petridis Dimitrios M. i *y?e o j report...experiencing a known number of filament failures per bundle. The results of this investigation are relevant to man-safe applications as in composite pressure...single filament r’iber testing and can become more 29 3> C o - Pwo PwS ?w4 Pw3 Pw2 Pwl PSD Ps5 PS4 Ps3 Ps2 PS! homoiogous correspondence t ~ to Life ( Laqt
Oesch, Peter; Meyer, Kathrin; Jansen, Beatrice; Mowinckel, Petter; Bachmann, Stefan; Hagen, Kare Birger
2012-02-15
Analytical cross-sectional study. To assess the association of "nonorganic somatic components" together with physical and other psychosocial factors on functional capacity evaluation (FCE) in patients with chronic nonspecific low back pain (NSLBP) undergoing fitness-for-work evaluation. Functional capacity evaluation is increasingly used for physical fitness-for-work evaluation in patients with chronic NSLBP, but results seem to be influenced by physical as well as psychosocial factors. The influence of nonorganic somatic components together with physical and other psychosocial factors on FCE performance has not yet been investigated. One hundred twenty-six patients with chronic NSLBP referred for physical fitness-for-work evaluation were included. The 4 FCE tests were lifting from floor to waist, forward bend standing, grip strength, and 6-minute walking. Nonorganic somatic components were assessed with the 8 nonorganic somatic signs as defined by Waddell and were adjusted for age, sex, days off work, salary in the previous occupation, pain intensity, fear avoidance belief, and perceived functional ability in multivariate regression analyses. Between 42% and 58% of the variation in the FCE tests was explained in the final multivariate regression models. Nonorganic somatic components were consistent independent predictors for all tests. Their influence was most important on forward bend standing and walking distance, and less on grip strength and lifting performance. The physical factors of age and/or sex were strongly associated with grip strength and lifting, less with walking distance, and not at all with forward bend standing. The influence of at least 1 other psychosocial factor was observed in all FCE tests, having the highest proportion in the 6-minute walking test. Nonorganic somatic components seem to be consistent independent predictors in FCE testing and should be considered for interpretation of test results.
NASA Technical Reports Server (NTRS)
Saulsberry, Regor; Greene, Nathanael; Cameron, Ken; Madaras, Eric; Grimes-Ledesma, Lorie; Thesken, John; Phoenix, Leigh; Murthy, Pappu; Revilock, Duane
2007-01-01
Many aging composite overwrapped pressure vessels (COPVs), being used by the National Aeronautics and Space Administration (NASA) are currently under evaluation to better quantify their reliability and clarify their likelihood of failure due to stress rupture and age-dependent issues. As a result, some test and analysis programs have been successfully accomplished and other related programs are still in progress at the NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) and other NASA centers, with assistance from the commercial sector. To support this effort, a group of Nondestructive Evaluation (NDE) experts was assembled to provide NDE competence for pretest evaluation of test articles and for application of NDE technology to real-time testing. Techniques were required to provide assurance that the test article had adequate structural integrity and manufacturing consistency to be considered acceptable for testing and these techniques were successfully applied. Destructive testing is also being accomplished to better understand the physical and chemical property changes associated with progression toward "stress rupture" (SR) failure, and it is being associated with NDE response, so it can potentially be used to help with life prediction. Destructive work also includes the evaluation of residual stresses during dissection of the overwrap, laboratory evaluation of specimens extracted from the overwrap to evaluate physical property changes, and quantitative microscopy to inform the theoretical micromechanics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrows, E.S.; Antrim, L.D.; Pinza, M.R.
1996-08-01
The U.S. Army Corps of Engineers (USACE) is authorized by Section 103 of the Marine Protection, Research, and Sanctuaries Act of 1972 (MPRSA), Public Law 92-532, and by the Clean Water Act of 1972 (CWA) and Amendments of 1977 to permit, evaluate, and regulate the disposal of dredged material in ocean waters to minimize adverse environmental effects. Compliance with the regulations of the MPRSA calls for physical and biological testing of sediment proposed for dredging prior to its disposal in ocean waters. The testing required by the MPRSA criteria is conducted under a testing manual developed by the USACE andmore » the U.S. Environmental Protection Agency (EPA), Evaluation of Dredged Material Proposed for Ocean Disposal (Testing Manual), commonly referred to as the `Green Book.` Testing protocols in the Green Book include bulk sediment analysis, grain size analysis, elutriate testing, and biological testing. The biological testing includes bioassays for acute toxicity as well as analysis to determine bioaccumulation of certain contaminants by marine organisms. The objective of the USACE-NYD Federal Projects Program was to evaluate sediment proposed for dredging and unconfined ocean disposal at the Mud Dump Site. The results of analytical measurements and bioassays performed on the test sediments were compared with analyses of sediment from the Mud Dump Reference Site to determine whether the test sediments were acutely toxic to marine organisms or resulted in statistically significantly greater bioaccumulation of contaminants in marine organisms, relative to the reference sediment. Testing for the federal project areas was performed according to the requirements.« less
Engineering behavior of small-scale foundation piers constructed from alternative materials
NASA Astrophysics Data System (ADS)
Prokudin, Maxim Mikhaylovich
Testing small-scale prototype pier foundations to evaluate engineering behavior is an alternative to full-scale testing that facilitates testing of several piers and pier groups at relatively low cost. In this study, various pier systems and pier groups at one tenth scale were subjected to static vertical loading under controlled conditions to evaluate stiffness, bearing capacity, and group efficiency. Pier length, material properties and methods of installation were evaluated. Pier length to diameter ratios varied between four and eight. A unique soil pit with dimensions of 2.1 m in width, 1.5 m in length and 2.0 m in depth was designed to carry out this research. The test pit was filled with moisture conditioned and compacted Western Iowa loess. A special load test frame was designed and fabricated to provide up to 25,000 kg vertical reaction force for load testing. A load cell and displacement instrumentation was setup to capture the load test data. Alternative materials to conventional cement concrete were studied. The pier materials evaluated in this study included compacted aggregate, cement stabilized silt, cementitious grouts, and fiber reinforced silt. Key findings from this study demonstrated that (1) the construction method influences the behavior of aggregate piers, (2) the composition of the pier has a significant impact on the stiffness, (3) group efficiencies were found to be a function of pier length and pier material, (4) in comparison to full-scale testing the scaled piers were found to produce a stiffer response with load-settlement and bearing capacities to be similar. Further, although full-scale test results were not available for all pier materials, the small-scale testing provided a means for comparing results between pier systems. Finally, duplicate pier tests for a given length and material were found to be repeatable.
Seed germination test for toxicity evaluation of compost: Its roles, problems and prospects.
Luo, Yuan; Liang, Jie; Zeng, Guangming; Chen, Ming; Mo, Dan; Li, Guoxue; Zhang, Difang
2018-01-01
Compost is commonly used for the growth of plants and the remediation of environmental pollution. It is important to evaluate the quality of compost and seed germination test is a powerful tool to examine the toxicity of compost, which is the most important aspect of the quality. Now the test is widely adopted, but the main problem is that the test results vary with different methods and seed species, which limits the development and application of it. The standardization of methods and the modelization of seeds can contribute to solving the problem. Additionally, according to the probabilistic theory of seed germination, the error caused by the analysis and judgment methods of the test results can be reduced. Here, we reviewed the roles, problems and prospects of the seed germination test in the studies of compost. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Krstulović-Opara, Lovre; Surjak, Martin; Vesenjak, Matej; Tonković, Zdenko; Kodvanj, Janoš; Domazet, Željko
2015-11-01
To investigate the applicability of infrared thermography as a tool for acquiring dynamic yielding in metals, a comparison of infrared thermography with three dimensional digital image correlation has been made. Dynamical tension tests and three point bending tests of aluminum alloys have been performed to evaluate results obtained by IR thermography in order to detect capabilities and limits for these two methods. Both approaches detect pastification zone migrations during the yielding process. The results of the tension test and three point bending test proved the validity of the IR approach as a method for evaluating the dynamic yielding process when used on complex structures such as cellular porous materials. The stability of the yielding process in the three point bending test, as contrary to the fluctuation of the plastification front in the tension test, is of great importance for the validation of numerical constitutive models. The research proved strong performance, robustness and reliability of the IR approach when used to evaluate yielding during dynamic loading processes, while the 3D DIC method proved to be superior in the low velocity loading regimes. This research based on two basic tests, proved the conclusions and suggestions presented in our previous research on porous materials where middle wave infrared thermography was applied.
Solid polymer electrolyte (SPE) fuel cell technology program, phase 2/2A. [testing and evaluations
NASA Technical Reports Server (NTRS)
1976-01-01
Test evaluations were performed on a fabricated single solid polymer electrolyte cell unit. The cell operated at increased current density and at higher performance levels. This improved performance was obtained through a combination of increased temperature, increased reactant pressures, improved activation techniques and improved thermal control over the baseline cell configuration. The cell demonstrated a higher acid content membrane which resulted in increased performance. Reduced catalyst loading and low cost membrane development showed encouraging results.
Hygrothermomechanical evaluation of transverse filament tape epoxy/polyester fiberglass composites
NASA Technical Reports Server (NTRS)
Lark, R. F.; Chamis, C. C.
1984-01-01
Transverse filament tape (TFT) fiberglass/epoxy and TFT polyester composites intended for low cost wind turbine blade fabrication have been subjected to static and cyclic load behavior tests whose results are presently evaluated on the basis of an integrated hygrothermomechanical response theory. Laminate testing employed simulated filament winding procedures. The results obtained show that the predicted hygrothermomechanical environmental effects on TFT composites are in good agreement with measured data for various properties, including fatigue at different R-ratio values.
NASA Technical Reports Server (NTRS)
Brown, David B.
1991-01-01
The results of research and development efforts of the first six months of Task 1, Phase 3 of the project are presented. The goals of Phase 3 are: (1) to further refine the rule base and complete the comparative rule base evaluation; (2) to implement and evaluate a concurrency testing prototype; (3) to convert the complete (unit-level and concurrency) testing prototype to a workstation environment; and (4) to provide a prototype development document to facilitate the transfer of research technology to a working environment. These goals were partially met and the results are summarized.
NASA Technical Reports Server (NTRS)
Lee, R. E.
2017-01-01
Electrochemical and crevice corrosion laboratory test results are presented for three noble metal candidates with possible application on the Universal Waste Management System (UWMS) in support of the Environmental Control and Life Support System (ECLSS) aboard the International Space Station (ISS). The three metal candidates, which included Inconel 625, Hastelloy C276 and Titanium 6Al-4V, were evaluated in two solutions representative of the acidic pretreatment formulations utilized during processing of waste liquids within the ECLSS. Final test results and data analysis indicated that the passive layer on all three metals provides excellent corrosion protection in both solutions under standard test conditions.
Testing and analysis of LWT and SCB properties of asphaltic concrete mixtures.
DOT National Transportation Integrated Search
2011-06-01
The objective of this research is to implement the loaded wheel tracker and to evaluate a simplified semi-circular bend test as an end result parameter for testing asphaltic concrete mixtures. The research will focus on testing both plant produced lo...
Construct Validity of Neuropsychological Tests in Schizophrenia.
ERIC Educational Resources Information Center
Allen, Daniel N.; Aldarondo, Felito; Goldstein, Gerald; Huegel, Stephen G.; Gilbertson, Mark; van Kammen, Daniel P.
1998-01-01
The construct validity of neuropsychological tests in patients with schizophrenia was studied with 39 patients who were evaluated with a battery of six tests assessing attention, memory, and abstract reasoning abilities. Results support the construct validity of the neuropsychological tests in patients with schizophrenia. (SLD)
14 CFR 120.111 - Administrative and other matters.
Code of Federal Regulations, 2014 CFR
2014-01-01
... ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.111 Administrative and other matters. (a... for the employer must be produced at the employer's place of business. (c) Release of drug testing information. An employer shall release information regarding an employee's drug testing results, evaluation...
14 CFR 120.111 - Administrative and other matters.
Code of Federal Regulations, 2012 CFR
2012-01-01
... ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.111 Administrative and other matters. (a... for the employer must be produced at the employer's place of business. (c) Release of drug testing information. An employer shall release information regarding an employee's drug testing results, evaluation...
14 CFR 120.111 - Administrative and other matters.
Code of Federal Regulations, 2010 CFR
2010-01-01
... ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.111 Administrative and other matters. (a... for the employer must be produced at the employer's place of business. (c) Release of drug testing information. An employer shall release information regarding an employee's drug testing results, evaluation...
14 CFR 120.111 - Administrative and other matters.
Code of Federal Regulations, 2013 CFR
2013-01-01
... ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.111 Administrative and other matters. (a... for the employer must be produced at the employer's place of business. (c) Release of drug testing information. An employer shall release information regarding an employee's drug testing results, evaluation...
14 CFR 120.111 - Administrative and other matters.
Code of Federal Regulations, 2011 CFR
2011-01-01
... ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.111 Administrative and other matters. (a... for the employer must be produced at the employer's place of business. (c) Release of drug testing information. An employer shall release information regarding an employee's drug testing results, evaluation...
An evaluation of grease type ball bearing lubricants operating in various environments
NASA Technical Reports Server (NTRS)
Mcmurtrey, E. L.
1979-01-01
Grease type lubricants in bearings were evaluated in five different adverse environments for a one year period. Four repetitions of each test were made to provide statistical samples. These tests were then used to select four lubricants for five year tests in selected environments with five repetitions of each test for statistical samples. Three five year tests were started in (1) continuous operation; (2) start-stop operation, with both in vacuum at ambient temperatures; and (3) continuous operation at 93.3 C. To date, in the one year tests, the best results in all environments were obtained with a high viscosity index perfluoroalkylpolyether grease.
[Cognitive dysfunction in patients with subclinical hypothyroidism].
Fernandes, Robertta Soares Miranda; Alvarenga, Nathália Bueno; Silva, Tamara Inácio da; Rocha, Felipe Filardi da
2011-04-01
Evaluate neuropsychological changes in patients with subclinical hypothyroidism (SH). Cross-sectional study comparing the results of the neuropsychological evaluation of 89 SH patients and 178 individuals without thyroid disease. The participants underwent the following neuropsychological assessment: Conner's Continuous Performance Test (CPT-II), Iowa Gambling Task, Stroop Test, Wisconsin Card Sorting Test (WCST), Verbal Fluency Test (semantic and phonologic categories) and Rey Auditory Verbal Learning Test. Among the neuropsychological tests, patients showed worse performance only in cognitive flexibility (WCST) and the ability to maintain sustained attention (omission errors on the CPT-II). These losses can cause detriments in the daily lives of patients, constituting potential treatment indications.
In-orbit evaluation of the control system/structural mode interactions of the OSO-8 spacecraft
NASA Technical Reports Server (NTRS)
Slafer, L. I.
1979-01-01
The Orbiting Solar Observatory-8 experienced severe structural mode/control loop interaction problems during the spacecraft development. Extensive analytical studies, using the hybrid coordinate modeling approach, and comprehensive ground testing were carried out in order to achieve the system's precision pointing performance requirements. A recent series of flight tests were conducted with the spacecraft in which a wide bandwidth, high resolution telemetry system was utilized to evaluate the on-orbit flexible dynamics characteristics of the vehicle along with the control system performance. The paper describes the results of these tests, reviewing the basic design problem, analytical approach taken, ground test philosophy, and on-orbit testing. Data from the tests was used to determine the primary mode frequency, damping, and servo coupling dynamics for the on-orbit condition. Additionally, the test results have verified analytically predicted differences between the on-orbit and ground test environments, and have led to a validation of both the analytical modeling and servo design techniques used during the development of the control system.
Laboratory Evaluation of Vocal Fold Paralysis and Paresis.
White, Michelle; Meenan, Kirsten; Patel, Tirth; Jaworek, Aaron; Sataloff, Robert T
2017-03-01
This study aimed to assess the value of comprehensive laboratory evaluation in patients with vocal fold paralysis or paresis. This is a retrospective chart review. Records of 231 patients with vocal fold paralysis or paresis were reviewed to determine whether there is a significant increase in the number of abnormal test results compared with rates of abnormal results for these tests in the general population and whether testing resulted in clinically important diagnosis. Laboratory data were collected from charts from initial visits from 2010 to 2014 and compared with national data. When controlled for age and sex, white blood cell count was found to have a significantly higher rate of abnormal test results (P < 0.001) in patients with vocal fold paralysis or paresis than the general population. Although hemoglobin, thyroid-stimulating hormone, and thyroid antibody tests were more likely to be abnormal in our patient population, the trend was not statistically significant. Further, the prevalence of syphilis and myasthenia gravis was found to be higher in these subjects than their respective national prevalences, and the incidence of Lyme disease was found to be higher than the national prevalence of Lyme disease. Several patients were diagnosed with medically important conditions such as diabetes, thyroid dysfunction, syphilis, myasthenia gravis, and Lyme disease based on these tests. This study suggests that comprehensive testing of patients with vocal fold movement disorders results in diagnoses that would be missed without a comprehensive evaluation, some of which are important medically, although their causal relationship to vocal fold paralysis or paresis was not investigated or established. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Ishaak, Fariel; de Vries, Nanne Karel; van der Wolf, Kees
2014-06-11
In this article, the test implementation of a school-oriented drug prevention program "Study without Drugs" is discussed. The aims of this study were to determine the results of the process evaluation and to determine whether the proposed school-oriented drug prevention program during a pilot project was effective for the participating pupils. Sixty second-grade pupils at a junior high school in Paramaribo, Suriname participated in the test implementation. They were divided into two classes. For the process evaluation the students completed a structured questionnaire focusing on content and teaching method after every lesson. Lessons were qualified with a score from 0-10. The process was also evaluated by the teachers through structured interviews. Attention was paid to reach, dose delivered, dose received, fidelity, connection, achieved effects/observed behaviors, areas for improvement, and lesson strengths. The effect evaluation was conducted by using the General Liniair Model (repeated measure). The research (-design) was a pre-experimental design with pre-and post-test. No class or sex differences were detected among the pupils with regard to the assessment of content, methodology, and qualification of the lessons. Post-testing showed that participating pupils obtained an increased knowledge of drugs, their drug-resisting skills were enhanced, and behavior determinants (attitude, subjective norm, self-efficacy, and intention) became more negative towards drugs. From the results of the test implementation can be cautiously concluded that the program "Study without Drugs" may yield positive results when applied in schools). Thus, this pilot program can be considered a step towards the development and implementation of an evidence-based school-oriented program for pupils in Suriname.
Manne, Sharon; Audrain, Janet; Schwartz, Marc; Main, David; Finch, Clinton; Lerman, Caryn
2004-12-01
Despite the potential importance of communication about genetic testing between test participants and their significant others, little is known about social support and communication between women undergoing BRCA1 and BRCA2 testing and their partners. The aims of this longitudinal study were to examine communication about genetic testing during and following testing and to evaluate whether communication is associated with psychological distress reported by test participants and their partners. Participants were 153 women who were undergoing genetic testing and 118 partners of women undergoing testing. Relationship communication and distress were evaluated at the time of pretest education and 6 months postdisclosure. Overall, the decision to undergo testing was discussed by the majority of test participants and partners, and most couples felt their partners were supportive. Most women disclosed their results to their partners. Longitudinal analyses suggested that less support and protective buffering were associated with greater distress 6 months postdisclosure among test participants, whereas lower comfort in sharing concerns and partner support were associated with lower distress 6 months postdisclosure among partners. The results of this study suggest that the majority of couples respond supportively during the test experience, but for a small subset of couples the process can strain the relationship. Partner support during this process is important, particularly for test participants dealing with an uninformative test result.
Bonnyaud, Céline; Fery, Yves-André; Bussel, Bernard; Roche, Nicolas
2017-01-01
Background Motor imagery (MI) capacity may be altered following stroke. MI is evaluated by measuring temporal congruence between the timed performance of an imagined and an executed task. Temporal congruence between imagined and physical gait-related activities has not been evaluated following stroke. Moreover, the effect of cognitive dysfunction on temporal congruence is not known. Objective To assess temporal congruence between the Timed Up and Go test (TUG) and the imagined TUG (iTUG) tests in patients with stroke and to investigate the role played by cognitive dysfunctions in changes in temporal congruence. Methods TUG and iTUG performance were recorded and compared in twenty patients with chronic stroke and 20 controls. Cognitive function was measured using the Montreal Cognitive Assessment (MOCA), the Frontal Assessment Battery at Bedside (FAB) and the Bells Test. Results The temporal congruence of the patients with stroke was significantly altered compared to the controls, indicating a loss of MI capacity (respectively 45.11 ±35.11 vs 24.36 ±17.91, p = 0.02). Furthermore, iTUG test results were positively correlated with pathological scores on the Bells Test (r = 0.085, p = 0.013), likely suggesting that impairment of attention was a contributing factor. Conclusion These results highlight the importance of evaluating potential attention disorder in patients with stroke to optimise the use of MI for rehabilitation and recovery. However further study is needed to determine how MI should be used in the case of cognitive dysfunction. PMID:28125616
Structural Test and Analysis of a Hybrid Inflatable Antenna
NASA Technical Reports Server (NTRS)
Gaspar, James L.; Mann, Troy; Sreekantamurthy, Tham; Behun, Vaughn
2007-01-01
NASA is developing ultra-lightweight structures technology for communication antennas for space missions. One of the research goals is to evaluate the structural characteristics of inflatable and rigidizable antennas through test and analysis. Being able to test and analyze the structural characteristics of a full scale antenna is important to enable the simulation of various mission scenarios to determine system performance in space. Recent work completed to evaluate a Hybrid Inflatable Antenna concept will be discussed. Tests were completed on a 2-m prototype to optimize its static shape and identify its modal dynamics that are important for analytical model validation. These test results were used to evaluate a preliminary finite element model of the antenna, and this model development and correlation activity is also described in the paper.
Examining publication bias—a simulation-based evaluation of statistical tests on publication bias
2017-01-01
Background Publication bias is a form of scientific misconduct. It threatens the validity of research results and the credibility of science. Although several tests on publication bias exist, no in-depth evaluations are available that examine which test performs best for different research settings. Methods Four tests on publication bias, Egger’s test (FAT), p-uniform, the test of excess significance (TES), as well as the caliper test, were evaluated in a Monte Carlo simulation. Two different types of publication bias and its degree (0%, 50%, 100%) were simulated. The type of publication bias was defined either as file-drawer, meaning the repeated analysis of new datasets, or p-hacking, meaning the inclusion of covariates in order to obtain a significant result. In addition, the underlying effect (β = 0, 0.5, 1, 1.5), effect heterogeneity, the number of observations in the simulated primary studies (N = 100, 500), and the number of observations for the publication bias tests (K = 100, 1,000) were varied. Results All tests evaluated were able to identify publication bias both in the file-drawer and p-hacking condition. The false positive rates were, with the exception of the 15%- and 20%-caliper test, unbiased. The FAT had the largest statistical power in the file-drawer conditions, whereas under p-hacking the TES was, except under effect heterogeneity, slightly better. The CTs were, however, inferior to the other tests under effect homogeneity and had a decent statistical power only in conditions with 1,000 primary studies. Discussion The FAT is recommended as a test for publication bias in standard meta-analyses with no or only small effect heterogeneity. If two-sided publication bias is suspected as well as under p-hacking the TES is the first alternative to the FAT. The 5%-caliper test is recommended under conditions of effect heterogeneity and a large number of primary studies, which may be found if publication bias is examined in a discipline-wide setting when primary studies cover different research problems. PMID:29204324
NASA Astrophysics Data System (ADS)
Perron, Stacey
Harsh Canadian winters cause many problems in reinforced concrete structures due to damaging freezing-thawing cycles which is exacerbated by the heavy use of de-icing salts on roadways. Evaluation of concrete durability with current ASTM methods may give unreliable results and are destructive to the structure. A relatively new and novel approach to evaluating the durability of concrete uses A. C. Impedance Spectroscopy (ACIS). Hydrated cement paste (hcp), mortar, brick and vycor glass were evaluated using ACIS during drying-rewetting and freezing-thawing cycles. Thermal mechanical analysis (TMA), and differential scanning calorimetry (DSC) tests were also conducted and used as references. Results indicate that ACIS can be used to successfully evaluate the pore structure of hcp. The results from the drying-rewetting cycles are consistent with the pore coarsening theory. ACIS revealed pore structure changes consistent with the mechanical strains and pore solution chemistry. Increased pore continuity with each drying-rewetting cycle was indicated by a reduction in sample resistance. Unique tests were conducted on hydrated cement paste, mortar, brick and vycor glass that measured the ACIS and mechanical strains simultaneously while undergoing temperature changes. The temperature was lowered from 5°C to -80°C and then raised to +20°C. The ACIS results indicate that durability of the material can be assessed using the parameters R, material resistance, and phi, indicative of the frequency dispersion angle. The resistance on freezing values correlates with the amount of pore water freezing. The phi values on freezing are representative of the pore size distribution of the test sample. Resistance and phi data from freezing-thawing tests can be analyzed to assess durability of the sample. A material that is durable to freezing-thawing cycles can be described as having a high resistance at room temperature, a low freezing resistance and small changes in phi. Results were consistent among all the materials tested. Freezing-thawing tests were also conducted on specimens resaturated with salt solutions (5%, 10%, 15%). The results of these tests indicated a lower incipient freezing temperature, increase in pore blockage temperatures, and increased mobility of the pore water during freezing (increase in the change to phi). A series of test were conducted to evaluate the electrode polarization effects associated with the permittivity values at low frequencies. Teflon sheets were used to minimize the electrode polarization effects. It is shown that electrode polarization effects dominate over bulk polarization effects. Effects vary with the porosity of the material.
Sanderson, Saskia C.; Wardle, Jane; Humphries, Steve E.
2008-01-01
Human genetics research is increasingly concerned with multifactorial conditions such as diabetes and heart disease, which are influenced not only by genetic but also lifestyle factors such as diet and smoking. Although the results of ‘lifestyle-genetic’ tests using this information could conceivably motivate lifestyle changes in the future, companies are already selling such tests and related lifestyle advice commercially. Some academics and lobby groups have condemned the companies for selling these tests in advance of scientific support. Others are concerned that the tests may not motivate lifestyle improvements, instead causing distress in people receiving adverse test results and complacency in those receiving reassuring results. There is currently no regulatory oversight of genetic test utility, despite consensus in the Public Health Genomics community that clinical utility (including psychological and behavioural impact) of all emerging genetic tests should be evaluated before being introduced for individual use. Clearly, empirical data in this area is much needed, to inform understanding of the potential utility of these tests, and of whether stricter regulation of commercial exploitation is needed. In this article, we review the current situation regarding lifestyle-genetic tests, and discuss the challenges inherent in conducting this kind of behavioural research in the genomics era. PMID:19776630
Cohen, Daniel M; Russo, Michael E; Jaggi, Preeti; Kline, Jennifer; Gluckman, William; Parekh, Amisha
2015-07-01
Rapid detection of group A beta-hemolytic streptococcus (GAS) is used routinely to help diagnose and treat pharyngitis. However, available rapid antigen detection tests for GAS have relatively low sensitivity, and backup testing is recommended in children. Newer assays are more sensitive yet require excessive time for practical point-of-care use as well as laboratory personnel. The Alere i strep A test is an isothermal nucleic acid amplification test designed to offer highly sensitive results at the point of care within 8 min when performed by nonlaboratory personnel. The performance of the Alere i strep A test was evaluated in a multicenter prospective trial in a Clinical Laboratory Improvement Amendments (CLIA)-waived setting in comparison to bacterial culture in 481 children and adults. Compared to culture, the Aleri i strep A test had 96.0% sensitivity and 94.6% specificity. Discrepant results were adjudicated by PCR and found the Alere i strep A test to have 98.7% sensitivity and 98.5% specificity. Overall, the Alere i strep A test could provide a one-step, rapid, point-of-care testing method for GAS pharyngitis and obviate backup testing on negative results. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Reske, Kimberly A.; Hink, Tiffany; Dubberke, Erik R.
2016-01-01
ABSTRACT The objective of this study was to evaluate the clinical characteristics and outcomes of hospitalized patients tested for Clostridium difficile and determine the correlation between pretest probability for C. difficile infection (CDI) and assay results. Patients with testing ordered for C. difficile were enrolled and assigned a high, medium, or low pretest probability of CDI based on clinical evaluation, laboratory, and imaging results. Stool was tested for C. difficile by toxin enzyme immunoassay (EIA) and toxigenic culture (TC). Chi-square analyses and the log rank test were utilized. Among the 111 patients enrolled, stool samples from nine were TC positive and four were EIA positive. Sixty-one (55%) patients had clinically significant diarrhea, 19 (17%) patients did not, and clinically significant diarrhea could not be determined for 31 (28%) patients. Seventy-two (65%) patients were assessed as having a low pretest probability of having CDI, 34 (31%) as having a medium probability, and 5 (5%) as having a high probability. None of the patients with low pretest probabilities had a positive EIA, but four were TC positive. None of the seven patients with a positive TC but a negative index EIA developed CDI within 30 days after the index test or died within 90 days after the index toxin EIA date. Pretest probability for CDI should be considered prior to ordering C. difficile testing and must be taken into account when interpreting test results. CDI is a clinical diagnosis supported by laboratory data, and the detection of toxigenic C. difficile in stool does not necessarily confirm the diagnosis of CDI. PMID:27927930
POLE.VAULT: A Semantic Framework for Health Policy Evaluation and Logical Testing.
Shaban-Nejad, Arash; Okhmatovskaia, Anya; Shin, Eun Kyong; Davis, Robert L; Buckeridge, David L
2017-01-01
The major goal of our study is to provide an automatic evaluation framework that aligns the results generated through semantic reasoning with the best available evidence regarding effective interventions to support the logical evaluation of public health policies. To this end, we have designed the POLicy EVAlUation & Logical Testing (POLE.VAULT) Framework to assist different stakeholders and decision-makers in making informed decisions about different health-related interventions, programs and ultimately policies, based on the contextual knowledge and the best available evidence at both individual and aggregate levels.
Loran Automatic Vehicle Monitoring System, Phase I : Volume 1. Test Results.
DOT National Transportation Integrated Search
1977-08-01
Presents results of the evaluation phase of a two phase program to develop an Automatic Vehicle Monitoring (AVM) system for the Southern California Rapid Transit District in Los Angeles, California. Tests were previously conducted on a Loran based lo...
Evaluation of I-FIT results and machine variability using MnRoad test track mixtures.
DOT National Transportation Integrated Search
2017-06-01
The Illinois Flexibility Index Test (I-FIT) was developed to distinguish between different mixtures in terms of potential cracking. Several : machines were manufactured and are currently available to perform the I-FIT. This report presents the result...
Fuzzy logic based sensor performance evaluation of vehicle mounted metal detector systems
NASA Astrophysics Data System (ADS)
Abeynayake, Canicious; Tran, Minh D.
2015-05-01
Vehicle Mounted Metal Detector (VMMD) systems are widely used for detection of threat objects in humanitarian demining and military route clearance scenarios. Due to the diverse nature of such operational conditions, operational use of VMMD without a proper understanding of its capability boundaries may lead to heavy causalities. Multi-criteria fitness evaluations are crucial for determining capability boundaries of any sensor-based demining equipment. Evaluation of sensor based military equipment is a multi-disciplinary topic combining the efforts of researchers, operators, managers and commanders having different professional backgrounds and knowledge profiles. Information acquired through field tests usually involves uncertainty, vagueness and imprecision due to variations in test and evaluation conditions during a single test or series of tests. This report presents a fuzzy logic based methodology for experimental data analysis and performance evaluation of VMMD. This data evaluation methodology has been developed to evaluate sensor performance by consolidating expert knowledge with experimental data. A case study is presented by implementing the proposed data analysis framework in a VMMD evaluation scenario. The results of this analysis confirm accuracy, practicability and reliability of the fuzzy logic based sensor performance evaluation framework.
Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 5, Appendix D
NASA Technical Reports Server (NTRS)
Klute, A.
1979-01-01
The electrical characterization and qualification test results are presented for the RCA MWS 5001D random access memory. The tests included functional tests, AC and DC parametric tests, AC parametric worst-case pattern selection test, determination of worst-case transition for setup and hold times, and a series of schmoo plots. Average input high current, worst case input high current, output low current, and data setup time are some of the results presented.