Sonsmann, F K; Strunk, M; Gediga, K; John, C; Schliemann, S; Seyfarth, F; Elsner, P; Diepgen, T L; Kutz, G; John, S M
2014-05-01
To date, there are no legally binding requirements concerning product testing in cosmetics. This leads to various manufacturer-specific test methods and absent transparent information on skin cleansing products. A standardized in vivo test procedure for assessment of cleansing efficacy and corresponding barrier impairment by the cleaning process is needed, especially in the occupational context where repeated hand washing procedures may be performed at short intervals. For the standardization of the cleansing procedure, an Automated Cleansing Device (ACiD) was designed and evaluated. Different smooth washing surfaces of the equipment for ACiD (incl. goat hair, felt, felt covered with nitrile caps) were evaluated regarding their skin compatibility. ACiD allows an automated, fully standardized skin washing procedure. Felt covered with nitrile as washing surface of the rotating washing units leads to a homogenous cleansing result and does not cause detectable skin irritation, neither clinically nor as assessed by skin bioengineering methods (transepidermal water loss, chromametry). Automated Cleansing Device may be useful for standardized evaluation of the cleansing effectiveness and parallel assessment of the corresponding irritancy potential of industrial skin cleansers. This will allow objectifying efficacy and safety of industrial skin cleansers, thus enabling market transparency and facilitating rational choice of products. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The Bali STD/AIDS study: association between vaginal hygiene practices and STDs among sex workers.
Reed, B D; Ford, K; Wirawan, D N
2001-02-01
To assess the association between genital cleansing practices and the prevalence of sexually transmitted diseases and of sexual health knowledge among female sex workers in Bali, Indonesia. Low priced commercial sex workers (CSWs) participated in the Bali STD/AIDS Study, a 3 year educational project evaluating the effect of education on the subsequent use of condoms and the prevalence of STDs and AIDS. Structured interviews, genital evaluation, laboratory evaluation for STDs, and treatment were performed. Vaginal cleansing characteristics including frequency, type, and reasons for use, were evaluated. Associations between these characteristics and the presence of bacterial and viral genital infections were assessed. Of 625 female sex workers evaluated between May and July 1998, 99.1% used substances, such as soap and toothpaste, to clean the vagina at least daily, with 69.3% performing this after each intercourse. The women using such cleansers after each client did not differ from those using them once or less daily in education, AIDS and condom use knowledge, time working as a CSW, or number of clients in the previous day. However, they were younger than those using vaginal cleansers daily or less, and reported lower condom usage in the past week. Several genital symptoms, such as discoloured discharge and odour, were reported less by women with the highest frequency of vaginal cleanser use. Prevalence of genital infections in this population of women was substantial, with bacterial infections more prevalent than viral infections. Infections were not associated with the type of cleanser used, using a genital cleanser on the day of examination, or using a cleanser after each client versus daily or less, except for candida colonisation, which was more prevalent in women cleansing after each client (OR=1.87, 95% CI 1.21, 2.90). However, symptomatic candida vulvovaginitis (positive culture plus presence of symptoms) was not associated with the prevalence of genital cleansing. Women using genital cleansing in part for "infection avoidance" (39.7%) were more likely to have heard of STDs and AIDS, but were less knowledgeable about these infections, compared with women not citing this reason for genital cleansing. Commercial sex workers in low priced brothels in Bali have a high rate of genital infections, with lower rates of viral compared with bacterial infections. Genital cleansers, on a daily or after each intercourse schedule, are used routinely. Although genital cleansing after each intercourse was associated with fewer genital symptoms, the prevalence of STDs did not differ significantly based on this frequency, and the women's knowledge of STDs and AIDS was less than that of women cleansing less often. The effect of genital cleansing in general on STD and AIDS prevalence could not be assessed in this population owing to the lack of a non-cleansing cohort. Further study to elucidate the effect of vaginal cleansing practices on STD prevalence and resistance is needed.
Bowel preparation for colonoscopy with magnesium sulphate and low-volume polyethylene glycol.
Tepeš, Bojan; Mlakar, Dominika N; Metličar, Tanja
2014-06-01
Patient compliance with bowel cleansing procedures represents one of the most objectionable aspects of colonoscopy. Adverse reactions to the purgative may result in failure to complete the preparation, inadequate visualization of the colon, polyp and even carcinoma miss rate and unwillingness to attend a follow-up colonoscopy. The primary objective of the study was to evaluate the effectiveness of bowel cleansing with magnesium sulphate and low-volume polyethylene glycol (PEG) with electrolytes. The second objective was to evaluate whether bowel cleansing was better in participants scheduled for morning colonoscopies or afternoon colonoscopies. Magnesium sulphate mineral water (2 l) and 2 l of low-volume PEG and electrolytes solution were used as our bowel cleansing protocol. A total of 13 914 participants, who participated in the Slovenian colorectal cancer screening programme in the period between 2009 and 2011, were included. Excellent bowel preparation was achieved in 11 484 (82.61%) participants; 1894 (13.62%) participants had good bowel preparation, 439 (3.16%) participants had fair bowel preparation and 85 (0.61%) participants had poor bowel preparation. Better results were achieved in the afternoon colonoscopies and in younger participant groups (P<0.001). No serious side effects of bowel cleansing were reported. This is the first study to use magnesium sulphate mineral water and PEG plus electrolytes for bowel cleansing. We found excellent bowel cleansing in 82.61% participants and in more participants if colonoscopy was performed in the afternoon.
Indirect latex glove contamination and its inhibitory effect on vinyl polysiloxane polymerization.
Kimoto, Katsuhiko; Tanaka, Kinya; Toyoda, Minoru; Ochiai, Kent T
2005-05-01
The inhibitory effect of indirect latex contamination on the polymerization of vinyl polysiloxane (VPS) impression material has been previously reported. However, the transfer of specific elements that cause inhibition has not been confirmed, nor has the removal of such contaminants been reported. This study examined the surfaces of materials commonly used in restorative procedures that were contaminated by indirect latex glove contact and then evaluated for inhibition of polymerization of VPS. The effect of selected cleansing procedures was then studied. Four experimental groups (n = 8) were prepared: (1) clean vinyl gloves (control), (2) clean gingival retraction cords (control), (3) contaminated vinyl gloves, and (4) contaminated gingival retraction cord. Microscopic evaluation of the appearance and the characterization of surface particulate contamination were performed for each. Three cleansing protocols were then evaluated for efficacy in cleaning vinyl glove surfaces contaminated by latex contact (n = 10): (1) brushing with water, (2) brushing with soap/rinsing with water, (3) cleansing with rubbing alcohol. The subsequent degree of VPS polymerization inhibition was evaluated subjectively. A chi-square test was used for data analysis (alpha=.05). Particulate sulfur elements and sulfur-chloride compounds were present on the contaminated substrates. None of the 3 cleansing procedures eliminated polymerization inhibition (P =.33). Residual elemental sulfur remained on all tested surfaces. Particulate sulfur and sulfur-chloride compounds were identified as the particulate contamination that resulted in polymerization inhibition of the tested VPS dental impression material. Removal of these contaminants from the tested vinyl gloves and gingival retraction cord was not possible with the 3 cleansing protocols tested in this study.
Safety, effectiveness and comparability of professional skin cleansers.
Terhaer, Flora K; Bock, Meike; Fartasch, Manigé; Gabard, Bernard; Elsner, Peter; Kleesz, Peter; Landeck, Lilla; Pohrt, Ute; Seyfarth, Florian; Schliemann, Sibylle; Diepgen, Thomas L; Zagrodnik, Fred; John, Swen Malte
2010-10-01
There are no widely-accepted methodical specifications with which to objectify cleansing effectiveness and skin compatibility of occuptional skin cleansing products in Europe. Therefore the German Social Insurance Agency (DGUV) initiated a study with the goal to evaluate such products in view of the potency and the safety of hand cleansers. A market analysis was a part of the project. The product descriptions and safety data sheets of 120 products (5-20/manufacturer) of 11 manufacturers were evaluated between 02/2008 and 04/2008. The manufacturers used mainly ingredients of low irritancy. The declaration of the applied ingredients was in the majority of the cases correctly labeled according to the INCI Declaration. Although there was documentation of skin tolerability for most products, the manufacturers used widely differing tests of skin compatibility. Evidences for cleansing effectiveness were not declared or have not been provided. One manufacturer even promised medical effects of its products. There was no uniform general classification of products making it difficult to identify characteristics of cleansers and choose between them. Presently, there are no commonly accepted criteria to classify products in view of cleansing effectiveness und skin compatibility. Generally accepted criteria and test methods are needed for the evaluation of hand cleansers in order to provide the possibility of transparency and comparability. © The Authors • Journal compilation © Blackwell Verlag GmbH, Berlin.
Evaluation of mild skin cleansers.
Wortzman, M S
1991-01-01
Each person makes the decision of how best to care for his or her own skin. Among the prime concerns, especially for facial skin, is the type of dirt, debris, or make-up to be removed. In most cases, all products do an adequate job in the removal of dirt; if not, the washing techniques can be modified to accomplish the task at hand. What cannot be controlled are the adverse side effects inherent in the use of that product. These adverse properties include damages to the barrier function of the skin; increased susceptibility to environmental sources of irritation and sensitization; frank irritation responses, such as erythema and edema; and reduction of the cosmetic qualities of the skin, such as degree of moisture and smoothness. Part of the problem is that most of these changes are subtle, occurring slowly over time. Often, the association of these problems with the use of a particular facial cleansing regimen is overlooked. The typical woman uses as many as 10 to 15 facial cosmetic and cleansing products each day, making the identification of a problem even more difficult. It is important to identify the risks associated with individual products and with product categories in general. Although the identification of a safe group of products to use for facial cleansing is desirable, the results of this investigation indicate that there are no simple answers. It has been assumed that because moisturizing cream formulations are routinely safe and mild in general use, a cleansing product in the same general form would share these attributes. We can see from the results in Table 2 and Figures 2, 3, 5, 7, and 9 that cleansing creams are not uniformly superior to cleansing bars in the key attributes that are used to evaluate mildness. In each evaluation there were individual cleansing creams that demonstrated statistically weaker performance than did cleansing bars in general. As a group, cleansing creams did well in the cosmetic categories of dryness and texture but surprisingly poorly in such indicators of clinical safety as erythema and TEWL. Further evaluation of the components of the facial-washing regimens proposed by the manufacturers of many of the cleansing-cream products involved the direct comparison of a cleansing cream against that same product used with an alcohol-based toning product. In all cases, the addition of alcohol-based products to the cleaning protocol reduced the cosmetic and clinical safety of the regimen (see Table 2 and Figures 3, 5, 7, and 9).(ABSTRACT TRUNCATED AT 400 WORDS)
A robust sebum, oil, and particulate pollution model for assessing cleansing efficacy of human skin.
Peterson, G; Rapaka, S; Koski, N; Kearney, M; Ortblad, K; Tadlock, L
2017-06-01
With increasing concerns over the rise of atmospheric particulate pollution globally and its impact on systemic health and skin ageing, we have developed a pollution model to mimic particulate matter trapped in sebum and oils creating a robust (difficult to remove) surrogate for dirty, polluted skin. To evaluate the cleansing efficacy/protective effect of a sonic brush vs. manual cleansing against particulate pollution (trapped in grease/oil typical of human sebum). The pollution model (Sebollution; sebum pollution model; SPM) consists of atmospheric particulate matter/pollution combined with grease/oils typical of human sebum. Twenty subjects between the ages of 18-65 were enrolled in a single-centre, cleansing study comparisons between the sonic cleansing brush (normal speed) compared to manual cleansing. Equal amount of SPM was applied to the centre of each cheek (left and right). Method of cleansing (sonic vs. manual) was randomized to the side of the face (left or right) for each subject. Each side was cleansed for five-seconds using the sonic cleansing device with sensitive brush head or manually, using equal amounts of water and a gel cleanser. Photographs (VISIA-CR, Canfield Imaging, NJ, USA) were taken at baseline (before application of the SPM), after application of SPM (pre-cleansing), and following cleansing. Image analysis (ImageJ, NIH, Bethesda, MD, USA) was used to quantify colour intensity (amount of particulate pollutants on the skin) using a scale of 0 to 255 (0 = all black pixels; 255 = all white pixels). Differences between the baseline and post-cleansing values (pixels) are reported as the amount of SPM remaining following each method of cleansing. Using a robust cleansing protocol to assess removal of pollutants (SPM; atmospheric particulate matter trapped in grease/oil), the sonic brush removed significantly more SPM than manual cleansing (P < 0.001). While extreme in colour, this pollution method easily allows assessment of efficacy through image analysis. © 2016 The Authors. International Journal of Cosmetic Science published by John Wiley & Sons Ltd on behalf of Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Subramanya, Supram Hosuru; Pai, Vasudha; Bairy, Indira; Nayak, Niranjan; Gokhale, Shishir; Sathian, Brijesh
2018-02-13
Raw vegetables including flowers, leaves, stems, and roots are important carriers of food borne pathogens. We evaluated the bacteriological contamination of unwashed coriander leaves, and effectiveness of cleansing with 0.1% potassium permanganate solution as decontamination method. Significant bacterial contamination including pathogens like Salmonella species and Aeromonas species were isolated from unwashed coriander leaves. Decontamination with 0.1% potassium permanganate was found to be more effective than three steps wash with sterile water.
Hong, Kyong Hee
2014-01-01
Colonoscopy is a widely accepted method for the evaluation of the colon and terminal ileum. Its diagnostic accuracy and therapeutic safety are influenced by prerequisites, including modulation of medication and bowel cleansing. Appropriate choices of sedative medication and bowel-cleansing regimen, together with diet modification, should be made based on the patient's underlying disease, age, and medication intake. Moreover, effective methods for patient education regarding bowel preparation should be considered. PMID:25133119
Genital region cleansing wipes: Effects on urine culture contamination.
Selek, Mehmet Burak; Bektöre, Bayhan; Sezer, Ogün; Kula Atik, Tuğba; Baylan, Orhan; Özyurt, Mustafa
2017-01-30
Urine culture is the gold standard test for revealing the microbial agent causing urinary tract infection (UTI). Culture results are affected by sampling techniques; improper sampling leads to contamination of urine and thus contamination of the culture with urogenital flora. We aimed to evaluate the effect of urogenital cleansing, performed with chlorhexidine-containing genital region cleansing wipes (GRCW) on contamination rates. A total of 2,665 patients with UTI-related complaints and with urine culture requests from various outpatient clinics were enrolled in the study. Of the patients, 1,609 in the experimental group used GRCW before sampling, while 1,046 in the control group did not use any wipes. The contamination rate in the experimental group patients was 7.7%, while it was 15.8% in the control group. Contamination rates were significantly higher in the control group than in the experimental group for both women and men. Contamination rates for children and adults were also significantly lower in the experimental group than in the control group. Our study, conducted in a large population, showed that the use of chlorhexidine-containing cleansing wipes significantly reduced urine culture contamination rates in both genders, in both child and adult age groups. Using GRCW, collection of urine after urogenital area cleansing will decrease the contamination problem.
Evaluation of a cleanser for petroleum-contaminated skin.
Phieffer, Laura S; Banks, David M; Bosse, Michael J; Meyer, Martha H; Meyer, Ralph A; Smith, Kevin
2003-12-01
Extremity injuries contaminated with petroleum products pose clinical dilemmas. This project was designed to evaluate the efficacy of a dioctyl sulfosuccinate (DS) solution for cleansing petroleum-contaminated skin. One hundred Sprague-Dawley rats were subjected to a contamination protocol followed by a cleansing procedure. Four petroleum contaminants and five cleansing solutions were selected. The protocol consisted of shaving, initial punch biopsy, contamination, precleansing punch biopsy, standardized scrub protocol, and postcleansing punch biopsy. Biopsy samples were analyzed for petroleum residue using fluorometry. The 10% DS solution had the highest reduction of crude oil, grease, and tar: 99.6 +/- 0.4% (mean +/- SD) contaminant reduction for crude oil, 99.8 +/- 0.2% for grease, and 99.8 +/- 0.2% for tar. The other cleansers showed less efficacy (p < 0.05). Concentrated DS appears to be significantly more effective at cleaning petroleum products from skin than the commonly chosen surgical and commercial cleansers.
A 25% tannic acid solution as a root canal irrigant cleanser: a scanning electron microscope study.
Bitter, N C
1989-03-01
A scanning electron microscope was used to evaluate the cleansing properties of a 25% tannic acid solution on the dentinal surface in the pulp chamber of endodontically prepared teeth. This was compared with the amorphous smear layer of the canal with the use of hydrogen peroxide and sodium hypochlorite solution as an irrigant. The tannic acid solution removed the smear layer more effectively than the regular cleansing agent.
Meshram, GK
2010-01-01
ABSTRACT Aim : To assess the cleaning efficacy of manual and automated instrumentation using 4% sodium hypochlorite singly and in combination with Glyde file Prep as root canal irrigant. Methodology : The study utilized 40 extracted human permanent premolars with single, straight and fully formed root. The teeth were then divided into four groups of ten each, Group I and II were prepared by manual instruments with 4% sodium hypochlorite used as irrigant singly [Group I] or in combination with Glyde file prep. Group III and IV were prepared by automated instruments at 250 rpm with 4% sodium hypochlorite as irrigant singly [Group III] and in combination with glyde file prep [Group IV] automated instrumentation. After completion of the root canal preparation the canal, teeth were prepared for SEM examination. These photomicrographs were qualitatively evaluated using criteria. Overall cleanliness, presence or absence of the smear layer, presence or absence of the debris, patency of the opening of dentinal tubules. Results : When comparing the cleansing efficacy of manual and automated instrumentation using 4% sodium hypochlorite better cleansing was there with manual instrumentation. When comparing the cleansing efficacy of manual and automated instrumentation using combination regime cleansing is better with automated instrumentation. When comparing the cleansing efficacy of manual instrumentation using 4% sodium hypochlorite singly and in combination with EDTA, the combination regime led to better cleansing. When comparing the cleansing efficacy of automated instrumentation using 4% sodium hypochlorite singly and in combination regime lead to better cleansing. Conclusion : Neither of instrumentation technique, nor irrigating regimes were capable of providing a completely clean canal. Automated instrumentation with a combination of sodium hypochlorite & EDTA resulted the best cleansing efficacy. PMID:27616839
Sheikh, Huma; Heymann, Harald O; Swift, Edward J; Ziemiecki, Thomas L; Ritter, André V
2010-12-01
This study determined the effect of saliva contamination and cleansing solutions on microtensile bond strengths of self-etch adhesives to dentin. Seventy-five human molars were ground flat to expose mid-coronal dentin and randomly assigned to five groups (N = 15): no contamination, saliva contamination without cleansing, saliva and cleansing with water, saliva and cleansing with 2% chlorhexidine, and saliva and cleansing with 5% sodium hypochlorite. One-third of the specimens in each group of 15 were bonded with Adper Prompt L-Pop (all-in-one self-etch adhesive; 3M ESPE, St. Paul, MN, USA), one-third with Adper Easy Bond (all-in-one self-etch adhesive; 3M ESPE), and one-third with Clearfil SE Bond (self-etch primer system; Kuraray America, New York, NY, USA). Specimens were restored with composite and processed for microtensile bond strength testing (5-6 rods/tooth). Mean bond strengths ranged from 17.3 MPa for Adper Prompt L-Pop after water cleansing to 69.3 MPa for Clearfil SE Bond after water cleansing. For all three adhesives, there was no statistically significant difference in bond strengths between the saliva contaminated group, the cleansing groups, and the no contamination groups. Neither saliva nor the cleansing solutions adversely affected bond strengths of the self-etch adhesive systems. © 2010, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2010, WILEY PERIODICALS, INC.
Haas, David M; Morgan, Sarah; Contreras, Karenrose
2014-09-09
Cesarean delivery is one of the most common surgical procedures performed by obstetricians. Infectious morbidity after cesarean delivery can have a tremendous impact on the postpartum woman's return to normal function and her ability to care for her baby. Despite the widespread use of prophylactic antibiotics, postoperative infectious morbidity still complicates cesarean deliveries. To determine if cleansing the vagina with an antiseptic solution before a cesarean delivery decreases the risk of maternal infectious morbidities, including endometritis and wound complications. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (21 July 2014). We included randomized and quasi-randomized trials assessing the impact of vaginal cleansing immediately before cesarean delivery with any type of antiseptic solution versus a placebo solution/standard of care on post-cesarean infectious morbidity. We independently assessed eligibility and quality of the studies. Five trials randomizing 1946 women (1766 analyzed) evaluated the effects of vaginal cleansing (all with povidone-iodine) on post-cesarean infectious morbidity. The risk of bias was generally low, with the quality of most of the studies being high. Vaginal preparation immediately before cesarean delivery significantly reduced the incidence of post-cesarean endometritis from 7.2% in control groups to 3.6% in vaginal cleansing groups (average risk ratio (RR) 0.39, 95% confidence interval (CI) 0.16 to 0.97, five trials, 1766 women). The risk reduction was particularly strong for women with ruptured membranes (1.4% in the vaginal cleansing group versus 15.4% in the control group; RR 0.13, 95% CI 0.02 to 0.66, two trials, 148 women). No other outcomes realized statistically significant differences between the vaginal cleansing and control groups. No adverse effects were reported with the povidone-iodine vaginal cleansing.The quality of the evidence using GRADE was low for post-cesarean endometritis, moderate for postoperative fever, and low for wound infection. Vaginal preparation with povidone-iodine solution immediately before cesarean delivery reduces the risk of postoperative endometritis. This benefit is particularly realized for women undergoing cesarean delivery with ruptured membranes. As a simple, generally inexpensive intervention, providers should consider implementing preoperative vaginal cleansing with povidone-iodine before performing cesarean deliveries.
Kitsongsermthon, J; Duangweang, K; Kreepoke, J; Tansirikongkol, A
2017-11-01
The plastic microbeads, used in many cleansers, will be banned in cosmetic and personal care products within 2017 since they are non-degradable and can disturb the living organisms in water reservoirs. Various choices of biodegradable beads are commercially available, but their efficacy has not been proven yet. This study aimed to compare the cleansing efficacy in dirt and sebum removal aspects of three types of exfoliating beads. The gel scrubs with polyethylene (PE) beads, mannan beads or wax beads, were formulated and evaluated for their stability. The in vivo evaluation was done in 38 healthy volunteers and the skin irritation, efficacy for dirt and sebum removal were measured by Mexameter ® , Colorimeter ® , and Sebumeter ® , respectively. The selected gel scrubs did not cause an irritation in any volunteers. The differences in dirt residues between before and after scrubbing were not statistically significant among three gel scrubs and the similar result was also reported in the sebum removal study. All gel scrubs demonstrated the comparable cleansing efficacy in term of dirt and sebum removal. Thus, mannan beads and wax beads may be replaced non-biodegradable PE beads to achieve the similar cleansing effect. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Harkrider, Lauren N.; Tamborski, Michael A.; Wang, Xiaoqian; Brown, Ryan P.; Mumford, Michael D.; Connelly, Shane; Devenport, Lynn D.
2015-01-01
Individuals engage in moral cleansing, a compensatory process to reaffirm one’s moral identity, when one’s moral self-concept is threatened. However, too much moral cleansing can license individuals to engage in future unethical acts. This study examined the effects of incentives and consequences of one’s actions on cheating behavior and moral cleansing. Results found that incentives and consequences interacted such that unethical thoughts were especially threatening, resulting in more moral cleansing, when large incentives to cheat were present and cheating explicitly harmed others. Implications are discussed in terms of ethics training, using incentives as motivators, and the depersonalized norms of science. PMID:26085781
Bartha, K; Rocca, J P
1993-12-01
The cleansing effectivity of citric acid solution was significantly better than that of Neomagnol both with respect to the removal of the Smear Layer (SL) and to the number of visible dentinal tubular orifices, however a complete elimination of the SL could not be obtained. Neomagnol seemed to be more effective in the removal of superficial debris and tissue-remnants.
Haas, David M; Morgan, Sarah; Contreras, Karenrose
2014-12-21
Cesarean delivery is one of the most common surgical procedures performed by obstetricians. Infectious morbidity after cesarean delivery can have a tremendous impact on the postpartum woman's return to normal function and her ability to care for her baby. Despite the widespread use of prophylactic antibiotics, postoperative infectious morbidity still complicates cesarean deliveries. To determine if cleansing the vagina with an antiseptic solution before a cesarean delivery decreases the risk of maternal infectious morbidities, including endometritis and wound complications. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (10 December 2014). We included randomized and quasi-randomized trials assessing the impact of vaginal cleansing immediately before cesarean delivery with any type of antiseptic solution versus a placebo solution/standard of care on post-cesarean infectious morbidity. We independently assessed eligibility and quality of the studies. Seven trials randomizing 2816 women (2635 analyzed) evaluated the effects of vaginal cleansing (all with povidone-iodine) on post-cesarean infectious morbidity. The risk of bias was generally low, with the quality of most of the studies being high. Vaginal preparation immediately before cesarean delivery significantly reduced the incidence of post-cesarean endometritis from 8.3% in control groups to 4.3% in vaginal cleansing groups (average risk ratio (RR) 0.45, 95% confidence interval (CI) 0.25 to 0.81, seven trials, 2635 women). The risk reduction was particularly strong for women who were already in labor at the time of the cesarean delivery (7.4% in the vaginal cleansing group versus 13.0% in the control group; RR 0.56, 95% CI 0.34 to 0.95, three trials, 523 women) and for women with ruptured membranes (4.3% in the vaginal cleansing group versus 17.9% in the control group; RR 0.24, 95% CI 0.10 to 0.55, three trials, 272 women). No other outcomes realized statistically significant differences between the vaginal cleansing and control groups. No adverse effects were reported with the povidone-iodine vaginal cleansing.The quality of the evidence using GRADE was low for post-cesarean endometritis, moderate for postoperative fever, and low for wound infection. Vaginal preparation with povidone-iodine solution immediately before cesarean delivery reduces the risk of postoperative endometritis. This benefit is particularly realized for women undergoing cesarean delivery, who are already in labor or who have ruptured membranes. As a simple, generally inexpensive intervention, providers should consider implementing preoperative vaginal cleansing with povidone-iodine before performing cesarean deliveries.
Colon cleansing protocol in children: research conditions vs. clinical practice.
Elitsur, Yoram; Balfaqih, Yaslam; Preston, Deborah
2018-04-01
Colon preparation rates are the limiting factor for a successful diagnostic colonoscopy in children. Different colon cleansing protocols have been published for use in children. Unfortunately, the applicability of those published research protocols has not been formally evaluated in routine clinical practice. We investigated the success rate of our previously published colon cleansing protocol as utilized in our clinical practice. This was a retrospective study. In the clinical practice, the colon cleansing protocol included PEG-3350 at a dose of 2 g/kg/day plus Dulcolax (Bisacodyl, Boehringer Ingelheim, TX USA) 5 mg/day for 2 days. Adequate colon preparation was graded between 1 - 5, as previously described, and grade ≥ 4.0 was considered an adequate preparation. Patients were instructed to complete a questionnaire that included PEG-3350 dose, number of stools per day, consistency of each stool, and side effects (vomiting, abdominal pain). Clinical and endoscopic results were compared between the protocol under research conditions and routine practice. The success rate of the colon preparation in our clinical practice was similar to the results observed under our research protocol (75 % vs. 73.6 %). Moreover, the total number of stools, stool consistency, and the intubation rate of the terminal ileum were also similar. We concluded, that in our experience, the colon cleansing protocol used under research conditions was effective and appropriate for use in routine clinical practice. We recommend testing each new protocol under the routine conditions of clinical practice to confirm its applicability for general practitioners.
Sloots, C E J; Felt-Bersma, R J F
2002-02-01
Colon transit time measurement with radio-opaque markers is a method of studying the passage of luminal contents throughout the colon. Overall colonic transit time (CTT), as well as segmental transit times [right (RTT), left (LTT) and rectosigmoid (RSTT)], can be calculated. We hypothesize that CTT is influenced by faecal impaction when the rectum is emptied infrequently. The aim of this study is to investigate the effect of bowel cleansing on colonic transit time in patients with chronic constipation. In 25 women (age 41 years; range 20-65 years) with constipation according to Thompson criteria, CTT measurement was performed in an unprepared situation and repeated after cleansing with 4 L of Klean-Prepreg. Ten healthy female volunteers (age 41 years; range 27-57 years) were used as controls. In constipated patients, CTT decreased from a median 70 h (range 10-130 h) to 48 h (5-94 h) in the cleansed state (P < 0.001). A shortening of transit time was found in all three segments. In 10 patients with slow transit (ST) (CTT > 86 h), CTT decreased from 110 h (range 94-130) to 86 (38-94) (P < 0.001). Five of the 10 patients with ST before bowel cleansing had a CTT below 86 h after cleansing. In female controls, uncleansed CTT and RSTT shortened from 39 h (23 to 62) and 17 h (8-29) to 29 h (17-48) and 10 h (0-20) after bowel cleansing (P=0.058 and P=0.046). Colonic intraluminal contents have a substantial effect on colonic transit. In female controls, bowel cleansing shortened rectosigmoid transit. Women with constipation had faster transit in the cleansed state, however, the distribution of markers was not altered. Despite the effect of bowel cleansing on CTT, it seems unnecessary to prepare the bowel in clinical practice because the differentiation of patients between slow transit constipation and outlet obstruction is not changed. However, because in an infrequent defecation pattern, the influence of faecal impaction is considerable, CTT should be applied with care for critical clinical decisions in the treatment of constipation.
2017-06-01
Reports an error in "Embodiment as procedures: Physical cleansing changes goal priming effects" by Ping Dong and Spike W. S. Lee ( Journal of Experimental Psychology: General , 2017[Apr], Vol 146[4], 592-605). In the article, the following F-value and p-values in the Results section of Experiment 3 were set incorrectly: The p -value p =.925 should be p =.922. The F - and p -values F (1, 201)=.011, p =.916 should be F (1, 201) .014, p = .906. (The following abstract of the original article appeared in record 2017-14922-010.) Physical cleansing reduces the influence of numerous psychological experiences, such as guilt from immoral behavior, dissonance from free choice, and good/bad luck from winning/losing. How do these domain-general effects occur? We propose an integrative account of cleansing as an embodied procedure of psychological separation. By separating physical traces from a physical target object (e.g., detaching dirt from hands), cleansing serves as the embodied grounding for the separation of psychological traces from a psychological target object (e.g., dissociating prior experience from the present self). This account predicts that cleansing reduces the accessibility of psychological traces and their consequences for judgments and behaviors. Testing these in the context of goal priming, we find that wiping one's hands (vs. not) decreases the mental accessibility (Experiment 1), behavioral expression (Experiment 2), and judged importance (Experiments 3-4) of previously primed goals (e.g., achievement, saving, fitness). But if a goal is primed after cleansing, its importance gets amplified instead (Experiment 3). Based on the logic of moderation-of-process, an alternative manipulation that psychologically separates a primed goal from the present self produces the same effects, but critically, the effects vanish once people wipe their hands clean (Experiment 4), consistent with the notion that cleansing functions as an embodied procedure of psychological separation. These findings have implications for the flexibility of goal pursuit. More broadly, our procedural perspective generates novel predictions about the scope and mechanisms of cleansing effects and may help integrate embodied and related phenomena. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Kalanthroff, Eyal; Aslan, Chen; Dar, Reuven
2017-01-01
The effect of threatened morality on negative emotions and on altruistic behaviour has been shown to diminish following physical cleansing (hand-washing). We hypothesised that threatened morality will broadly impair the executive control system, and that physical cleansing will moderate this detrimental effect. Thirty-seven participants were asked to write about an immoral deed they had committed, whereupon half of them were allowed to wipe their hands. Three executive control tasks-Stroop, stop-signal, and object interference-were then administered to all participants. Participants who had not wiped their hands, but not those who did, demonstrated impaired performance, compared to hand-washing controls, in all three tasks. We conclude that threatened morality has a detrimental effect on executive control, specifically on conflict monitoring and response inhibition, and that physical cleansing "frees" this system, counteracting the detrimental effects of morality threats. We discuss possible implications for obsessive-compulsive disorder, which is characterised by deficient executive control and in which both threatened morality and physical cleansing are central concerns.
Change in the nose areas in children with mouth breathing after nasal cleansing and massage.
Melo, Ana Carolina Cardoso de; Gomes, Adriana de Oliveira Camargo; Cunha, Daniele Andrade da; Lima, Sandro Júnior Henrique; Lima, Wigna Rayssa Pereira; Cunha, Renata Andrade da; Silva, Hilton Justino da
2016-01-01
To analyze the changes occurred in the nasal cavity geometry, before and after nasal cleansing, through nasal aeration and acoustic rhinometry in children with oral breathing. Twenty children aged four to 12 years were included in the study. The gathering of participants was conducted at the Multifunctional Laboratory of the Speech Pathology Department of the Federal University of Pernambuco - UFPE. The following procedures were conducted: Identification Index of Signs and Symptoms of Oral Breathing; marking of nasal expiratory airflow using the graded mirror of Altmann, and examination of the Nasal Geometry by Acoustic Rhinometry. The same procedures were performed after nasal massage and cleansing with saline solution. Significant change was observed in the areas with respect to the nasal airflow on both sides after nasal cleansing and massage. As for nasal geometry, measured by acoustic rhinometry, comparison between the nostrils showed that the effect of cleansing and massage was discrete. Nasal aeration measures showed sensitivity to the cleansing and massage technique and measures of nasal geometry confirmed its effect on respiratory physiology.
Franek, Jacob; Leibach, Elizabeth K.; Weissfeld, Alice S.; Kraft, Colleen S.; Sautter, Robert L.; Baselski, Vickie; Rodahl, Debra; Peterson, Edward J.; Cornish, Nancy E.
2015-01-01
SUMMARY Background. Urinary tract infection (UTI) in the United States is the most common bacterial infection, and urine cultures often make up the largest portion of workload for a hospital-based microbiology laboratory. Appropriately managing the factors affecting the preanalytic phase of urine culture contributes significantly to the generation of meaningful culture results that ultimately affect patient diagnosis and management. Urine culture contamination can be reduced with proper techniques for urine collection, preservation, storage, and transport, the major factors affecting the preanalytic phase of urine culture. Objectives. The purposes of this review were to identify and evaluate preanalytic practices associated with urine specimens and to assess their impact on the accuracy of urine culture microbiology. Specific practices included collection methods for men, women, and children; preservation of urine samples in boric acid solutions; and the effect of refrigeration on stored urine. Practice efficacy and effectiveness were measured by two parameters: reduction of urine culture contamination and increased accuracy of patient diagnosis. The CDC Laboratory Medicine Best Practices (LMBP) initiative's systematic review method for assessment of quality improvement (QI) practices was employed. Results were then translated into evidence-based practice guidelines. Search strategy. A search of three electronic bibliographic databases (PubMed, SCOPUS, and CINAHL), as well as hand searching of bibliographies from relevant information sources, for English-language articles published between 1965 and 2014 was conducted. Selection criteria. The search contained the following medical subject headings and key text words: urinary tract infections, UTI, urine/analysis, urine/microbiology, urinalysis, specimen handling, preservation, biological, preservation, boric acid, boric acid/borate, refrigeration, storage, time factors, transportation, transport time, time delay, time factor, timing, urine specimen collection, catheters, indwelling, urinary reservoirs, continent, urinary catheterization, intermittent urethral catheterization, clean voided, midstream, Foley, suprapubic, bacteriological techniques, and microbiological techniques. Main results. Both boric acid and refrigeration adequately preserved urine specimens prior to their processing for up to 24 h. Urine held at room temperature for more than 4 h showed overgrowth of both clinically significant and contaminating microorganisms. The overall strength of this body of evidence, however, was rated as low. For urine specimens collected from women, there was no difference in rates of contamination for midstream urine specimens collected with or without cleansing. The overall strength of this evidence was rated as high. The levels of diagnostic accuracy of midstream urine collection with or without cleansing were similar, although the overall strength of this evidence was rated as low. For urine specimens collected from men, there was a reduction in contamination in favor of midstream clean-catch over first-void specimen collection. The strength of this evidence was rated as high. Only one study compared midstream collection with cleansing to midstream collection without cleansing. Results showed no difference in contamination between the two methods of collection. However, imprecision was due largely to the small event size. The diagnostic accuracy of midstream urine collection from men compared to straight catheterization or suprapubic aspiration was high. However, the overall strength of this body of evidence was rated as low. For urine specimens collected from children and infants, the evidence comparing contamination rates for midstream urine collection with cleansing, midstream collection without cleansing, sterile urine bag collection, and diaper collection pointed to larger reductions in the odds of contamination in favor of midstream collection with cleansing over the other methods of collection. This body of evidence was rated as high. The accuracy of diagnosis of urinary tract infection from midstream clean-catch urine specimens, sterile urine bag specimens, or diaper specimens compared to straight catheterization or suprapubic aspiration was varied. Authors' conclusions. No recommendation for or against is made for delayed processing of urine stored at room temperature, refrigerated, or preserved in boric acid. This does not preclude the use of refrigeration or chemical preservatives in clinical practice. It does indicate, however, that more systematic studies evaluating the utility of these measures are needed. If noninvasive collection is being considered for women, midstream collection with cleansing is recommended, but no recommendation for or against is made for midstream collection without cleansing. If noninvasive collection is being considered for men, midstream collection with cleansing is recommended and collection of first-void urine is not recommended. No recommendation for or against is made for collection of midstream urine without cleansing. If noninvasive collection is being considered for children, midstream collection with cleansing is recommended and collection in sterile urine bags, from diapers, or midstream without cleansing is not recommended. Whether midstream collection with cleansing can be routinely used in place of catheterization or suprapubic aspiration is unclear. The data suggest that midstream collection with cleansing is accurate for the diagnosis of urinary tract infections in infants and children and has higher average accuracy than sterile urine bag collection (data for diaper collection were lacking); however, the overall strength of evidence was low, as multivariate modeling could not be performed, and thus no recommendation for or against can be made. PMID:26598386
de Moura, Diogo Turiani; Guedes, Hugo; Tortoretto, Verônica; Arataque, Tayrê Pádua; de Moura, Eduardo Guimarães; Román, Juan Pablo; Rodela, Gustavo Luis; Artifon, Everson L
2016-01-01
The purpose of the present study is to compare intestinal preparation with mannitol and sodium picosulphate, assessing patient's acceptance, side effects and cleaning capacity. This is a prospective, nom randomized, blind study, in which the evaluator had no information about the preparation applied. The sample obtained was divided into two groups according to the bowel preparation applied, with 153 patients prepared with 10% mannitol and 84 patients with sodium picosulfate. The evaluation of colon preparation was done using the Boston Scale (Boston Bowel Preparation Scale - BBP) through a three-point scoring system for each of the three regions of the colon: right, left and transverse colon. Of the 237 patients that were evaluated, 146 (61.60%) were female and 91 (38.4%) were male. Regarding the group that used mannitol, 98 were female (64.05%) and 55 were male (35.95%). Among the patients who used sodium picosulfate, 48 were female (57.14%) and 36 were male (42.86%), with no statistical differences between both groups (p> 0.32). Considering that an adequate preparation scores ≥ 6 in the Boston Scale, the bowel cleansing preparation was satisfactory in both groups. 93% of the patients who used mannitol and 81% of the patients who used sodium picosulfate had adequate preparation (score of ≥ 6). Moreover, we consider that the average score in the preparation with Mannitol was 9, while the sodium picosulfate score was 7. There were no significant differences between the two groups. There is consensus among authors who state that colonoscopy's safety and success are highly related to the cleansing outcome, regardless of the method used. The same can be observed in the present study, on which both preparations were proved safe and effective for bowel cleansing, according to the Boston scale, as well as accepted by patients and free of complications.
Felt-Bersma, R J; Kooyman, G; Kuipers, E J
2004-01-24
Comparison of three cleansing solutions for bowel preparation prior to colonoscopy. Prospective, randomized. 140 outpatients referred for colonoscopy were randomized into three groups for cleansing with 4 litres PEG 4000, 4 litres PEG 3350 or with 90 ml sodium phosphate with an additional 2.5 litres of fluid. Between cleansing and colonoscopy, patients filled in a questionnaire concerning taste, abdominal cramps and tolerance to the procedure. Blinded to the type of cleansing the endoscopist scored the effects on the colon and rectosigmoid, and made the endoscopic diagnosis. All data were available for 127 of the 140 patients (50 men, 77 women), mean age 51 years (range 18-96). Comparison between the three groups showed no statistically significant difference in the opinion of the patients concerning taste, abdominal cramps and tolerance of lavage. The endoscopist's scoring of total colon cleansing showed a small reduction in colon cleanliness when using sodium phosphate compared to PEG 3350 (p = 0.03). No differences were found between the two PEG solutions. Combining both PEG solutions and comparing them with the sodium-phosphate solution showed fewer abdominal cramps (p = 0.07) with sodium phosphate and a cleaner colon with PEG (p = 0.07). Women complained slightly more of abdominal cramps and were slightly less tolerant of the procedure than men. Previous colonic surgery did not influence the results. Patients with diverticula were older, but no other effect of cleansing was found. The three preparations are comparable in their cleansing effect and tolerance by the patient.
Sofi, Aijaz A; Nawras, Ali T; Pai, Chetan; Samuels, Qiana; Silverman, Ann L
2015-01-01
Bowel preparation using large volume of polyethylene glycol (PEG) solutions is often poorly tolerated. Therefore, there are ongoing efforts to develop an alternative bowel cleansing regimen that should be equally effective and better tolerated. The aim of this study was to assess the efficacy of lubiprostone (versus placebo) plus PEG as a bowel cleansing preparation for colonoscopy. Our study was a randomized, double-blind placebo-controlled design. Patients scheduled for screening colonoscopy were randomized 1:1 to lubiprostone (group 1) or placebo (group 2) plus 1 gallon of PEG. The primary endpoints were patient's tolerability and endoscopist's evaluation of the preparation quality. The secondary endpoint was to determine any reduction in the amount of PEG consumed in the lubiprostone group compared with the placebo group. One hundred twenty-three patients completed the study and were included in the analysis. There was no difference in overall cleanliness. The volume of PEG was similar in both the groups. The volume of PEG approached significance as a predictor of improved score for both the groups (P = 0.054). Lubiprostone plus PEG was similar to placebo plus PEG in colon cleansing and volume of PEG consumed. The volume of PEG consumed showed a trend toward improving the quality of the colon cleansing.
Cesaro, Paola; Hassan, Cesare; Spada, Cristiano; Petruzziello, Lucio; Vitale, Giovanna; Costamagna, Guido
2013-01-01
4-L polyethylene glycol preparations are effective for colon cleansing before colonoscopy. However, large volume and unpleasant taste reduce tolerability and acceptability limiting patient compliance. A new isosmotic low-volume polyethylene glycol preparation with citrates and simethicone plus bisacodyl has been developed to improve patient compliance and tolerability. To compare the efficacy of 2 different regimens of preparation vs a split-dose of polyethylene glycol solution. In this randomised, blinded, comparative study, 153 patients were allocated to 3 arms. Arm 1 (n=52) received bisacodyl and 2-L polyethylene glycol with citrates and simethicone the day before the procedure. Arm 2 (n=50) received bisacodyl the day before and 2-L polyethylene glycol with citrates and simethicone on the day of colonoscopy. Control group (n=51) received a split-dose of 4-L polyethylene glycol. Cleansing was evaluated according to Ottawa scale. The mean Ottawa score was not different in the 3 groups. Excellent cleansing was observed more frequently in arm 2 (70%) than in controls (49%) (p<0.05). No serious adverse events were observed in the 3 regimens. The willingness to repeat the same bowel preparation was superior in arms 1 and 2 than in controls (p<0.001). New low-volume preparations seem to be as effective as the split 4-L polyethylene glycol regimen, showing a better tolerability and acceptability. Copyright © 2012. Published by Elsevier Ltd.
Informatics in Radiology: Dual-Energy Electronic Cleansing for Fecal-Tagging CT Colonography
Kim, Se Hyung; Lee, June-Goo; Yoshida, Hiroyuki
2013-01-01
Electronic cleansing (EC) is an emerging technique for the removal of tagged fecal materials at fecal-tagging computed tomographic (CT) colonography. However, existing EC methods may generate various types of artifacts that severely impair the quality of the cleansed CT colonographic images. Dual-energy fecal-tagging CT colonography is regarded as a next-generation imaging modality. EC that makes use of dual-energy fecal-tagging CT colonographic images promises to be effective in reducing cleansing artifacts by means of applying the material decomposition capability of dual-energy CT. The dual-energy index (DEI), which is calculated from the relative change in the attenuation values of a material at two different photon energies, is a reliable and effective indicator for differentiating tagged fecal materials from various types of tissues on fecal-tagging CT colonographic images. A DEI-based dual-energy EC scheme uses the DEI to help differentiate the colonic lumen—including the luminal air, tagged fecal materials, and air-tagging mixture—from the colonic soft-tissue structures, and then segments the entire colonic lumen for cleansing of the tagged fecal materials. As a result, dual-energy EC can help identify partial-volume effects in the air-tagging mixture and inhomogeneous tagging in residual fecal materials, the major causes of EC artifacts. This technique has the potential to significantly improve the quality of EC and promises to provide images of a cleansed colon that are free of the artifacts commonly observed with conventional single-energy EC methods. © RSNA, 2013 PMID:23479680
Leite, Brisa Dos Santos; Fagundes, Nathalia Carolina Fernandes; Aragón, Mônica Lídia Castro; Dias, Carmen Gilda Barroso Tavares; Normando, David
2016-01-01
Debris buildup on the bracket-wire interface can influence friction. Cleansing brackets with air-powder polishing can affect this process. The aim of this study was to evaluate the frictional force and amount of debris remaining on orthodontic brackets subjected to prophylaxis with air-powder polishing. Frictional force and debris buildup on the surface of 28 premolar brackets were evaluated after orthodontic treatment. In one hemiarch, each bracket was subjected to air-powder polishing (n = 14) for five seconds, while the contralateral hemiarch (n = 14) served as control. Mechanical friction tests were performed and images of the polished bracket surfaces and control surfaces were examined. Wilcoxon test was applied for comparative analysis between hemiarches at p < 0.05. Brackets that had been cleaned with air-powder polishing showed lower friction (median = 1.27 N) when compared to the control surfaces (median = 4.52 N) (p < 0.01). Image analysis showed that the control group exhibited greater debris buildup (median = 2.0) compared with the group that received prophylaxis with air-powder polishing (median = 0.5) (p < 0.05). Cleansing orthodontic brackets with air-powder polishing significantly reduces debris buildup on the bracket surface while decreasing friction levels observed during sliding mechanics.
Evaluating cleansing effects on trace elements and stable isotope values in feathers of oiled birds.
Valladares, Sonia; Moreno, Roćio; Jover, Lluis; Sanpera, Carola
2010-01-01
Feathers of seabirds are widely used as a nondestructive tissue for pollution monitoring of trace elements, as well as convenient samples for trophic ecology studies by means of stable isotope analysis (SIA). Nevertheless, feathers can be occasionally impregnated with oil from deliberate ship discharges and from massive oil spill accidents. The feather structure makes them effective traps for particles and are subject to external contamination. It is unknown to what extent the oil adhered to feathers can change trace element concentrations or stable isotope signatures. This study has two primary objectives: (1) to assess if there are differences between trace element concentrations and stable isotope signatures of oiled and clean feathers, and (2) to determine if the cleansing of oiled feathers using commonly applied techniques such as sodium hydroxide (NaOH) washes in combination with an organic solvent (hexane) is more effective than using NaOH alone. In order to do this, we analysed trace elements (Se, Hg, Pb, Cu and Zn) and stable isotopes (delta(13)C and delta(15)N) of individual feathers of yellow-legged gulls (Larus michahellis) which were affected by the 2002 Prestige oil spill in Galicia (NW Spain). Two sets of feathers were analysed, one group were oil-free (Control group) and the other had oil adhered to its surface (Oiled group). We expected to find differences between control and oiled feathers when cleaning exclusively with NaOH and no differences when using hexane. Our results did not show significant differences between Control and Oiled groups as a consequence of the cleansing method used. Unexpectedly, the additional cleansing with hexane resulted in decreasing selenium concentrations and increasing zinc and delta(15)N values in all groups of feathers.
Low-dose dual-energy electronic cleansing for fecal-tagging CT Colonography
NASA Astrophysics Data System (ADS)
Cai, Wenli; Zhang, Da; Lee, June-Goo; Yoshida, Hiroyuki
2013-03-01
Dual-energy electronic cleansing (DE-EC) provides a promising means for cleansing the tagged fecal materials in fecaltagging CT colonography (CTC). However, the increased radiation dose due to the double exposures in dual-energy CTC (DE-CTC) scanning is a major limitation for the use of DE-EC in clinical practice. The purpose of this study was to develop and evaluate a low-dose DE-EC scheme in fecal-tagging DE-CTC. In this study, a custom-made anthropomorphic colon phantom, which was filled with simulated tagged materials by non-ionic iodinated contrast agent (Omnipaque iohexol, GE Healthcare), was scanned by a dual-source CT scanner (SOMATON Definition Flash, Siemens Healthcare) at two photon energies: 80 kVp and 140 kVp with nine different tube current settings ranging from 12 to 74 mAs for 140 kVp, and then reconstructed by soft-tissue reconstruction kernel (B30f). The DE-CTC images were subjected to a low-dose DE-EC scheme. First, our image-space DE-CTC denoising filter was applied for reduction of image noise. Then, the noise-reduced images were processed by a virtual lumen tagging method for reduction of partial volume effect and tagging inhomogeneity. The results were compared with the registered CTC images of native phantom without fillings. Preliminary results showed that our low-dose DE-EC scheme achieved the cleansing ratios, defined by the proportion of the cleansed voxels in the tagging mask, between 93.18% (12 mAs) and 96.62% (74 mAs). Also, the soft-tissue preservation ratios, defined by the proportion of the persevered voxels in the soft-tissue mask, were maintained in the range between 94.67% and 96.41%.
Polyethylene glycol plus simethicone in small-bowel preparation for capsule endoscopy.
Spada, Cristiano; Riccioni, Maria E; Familiari, Pietro; Spera, Gianluca; Pirozzi, Giuseppe A; Marchese, Michele; Bizzotto, Alessandra; Ingrosso, Marcello; Costamagna, Guido
2010-05-01
Small-bowel contents can hamper the quality of video-capsule endoscopy (VCE). No standardized protocol has been proposed and overnight fasting remains the proposed preparation for VCE. The aim was to evaluate the effects of 2 regimens of bowel preparation on small intestine cleansing, diagnostic yield and capsule transit times. This is a prospective, randomized, blinded, and controlled study. Sixty patients referred for VCE were randomized into 2 groups. Group A ingested 2l of a polyethylene glycol and simethicone solution 16h before VCE. Group B were instructed to consume a fibre-free diet and allowed to consume clear liquids the day before VCE. The small-bowel cleansing was graded as "complete" if the entire wall was assessable, "incomplete" if more than 50% of the wall was visible, and "insufficient" if less than 50% of the wall was visible. In group A, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 42%, 39% and 19% of cases respectively. In group B, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 43%, 33% and 24% of cases respectively. No significant differences were observed between the two groups, regarding small-bowel cleansing level (p=0.65). No differences were also observed in the diagnostic yield (48.2%, 13.8% and 38% vs 65.5%, 6.9% and 27.6% of positive, suspicious and no findings respectively, in groups A and B [p=0.39]) and small-bowel transit times (mean 288min and 299 min in groups A and B respectively [p=0.70]). The results of the present study do not support the use of 2l of a polyethylene glycol and simethicone solution before VCE. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Bartha, K; Rocca, J P
1993-11-01
The aim of the study was to assess the cleansing-effect of two endodontic handpieces (Excalibur, W & H; MM 1400 Micro Méga) in root canals that were previously manually prepared, and treated with chlor-(Neomagnol) and citric acid containing solutions. The analyses were performed by scanning electron microscope (SEM). The elimination of the Smear Layer (SL) with Neomagnol was not successful with either of the two handpieces. The cleansing of the Superficial Debris (SD) with Neomagnol activated by MM 1400 was significantly more effective in the apical (p < 0.05) and in the middle (p < 0.01) third of the root-canal, than by Excalibur. In contrast, SL was better eliminated by Excalibur using citric acid, significant differences--when compared with MM 1400--could be seen in the middle third (p < 0.05) of the root-canal. The handpieces seem to have their own specific characteristics: thus MM 1400 was better in eliminating the SD (used with Neomagnol), while Excalibur was superior in eliminating the SL (used with citric acid).
Addition of senna improves quality of colonoscopy preparation with magnesium citrate.
Vradelis, Stergios; Kalaitzakis, Evangelos; Sharifi, Yalda; Buchel, Otto; Keshav, Satish; Chapman, Roger W; Braden, Barbara
2009-04-14
To prospectively investigate the effectiveness and patient's tolerance of two low-cost bowel cleansing preparation protocols based on magnesium citrate only or the combination of magnesium citrate and senna. A total of 342 patients who were referred for colonoscopy underwent a colon cleansing protocol with magnesium citrate alone (n = 160) or magnesium citrate and senna granules (n = 182). The colonoscopist rated the overall efficacy of colon cleansing using an established score on a 4-point scale. Patients were questioned before undergoing colonoscopy for side effects and symptoms during bowel preparation. The percentage of procedures rescheduled because of insufficient colon cleansing was 7% in the magnesium citrate group and 4% in the magnesium citrate/senna group (P = 0.44). Adequate visualization of the colonic mucosa was rated superior under the citramag/senna regimen (P = 0.004). Both regimens were well tolerated, and did not significantly differ in the occurrence of nausea, bloating or headache. However, abdominal cramps were observed more often under the senna protocol (29.2%) compared to the magnesium citrate only protocol (9.9%, P < 0.0003). The addition of senna to the bowel preparation protocol with magnesium citrate significantly improves the cleansing outcome.
Addition of senna improves quality of colonoscopy preparation with magnesium citrate
Vradelis, Stergios; Kalaitzakis, Evangelos; Sharifi, Yalda; Buchel, Otto; Keshav, Satish; Chapman, Roger W; Braden, Barbara
2009-01-01
AIM: To prospectively investigate the effectiveness and patient’s tolerance of two low-cost bowel cleansing preparation protocols based on magnesium citrate only or the combination of magnesium citrate and senna. METHODS: A total of 342 patients who were referred for colonoscopy underwent a colon cleansing protocol with magnesium citrate alone (n = 160) or magnesium citrate and senna granules (n = 182). The colonoscopist rated the overall efficacy of colon cleansing using an established score on a 4-point scale. Patients were questioned before undergoing colonoscopy for side effects and symptoms during bowel preparation. RESULTS: The percentage of procedures rescheduled because of insufficient colon cleansing was 7% in the magnesium citrate group and 4% in the magnesium citrate/senna group (P = 0.44). Adequate visualization of the colonic mucosa was rated superior under the citramag/senna regimen (P = 0.004). Both regimens were well tolerated, and did not significantly differ in the occurrence of nausea, bloating or headache. However, abdominal cramps were observed more often under the senna protocol (29.2%) compared to the magnesium citrate only protocol (9.9%, P < 0.0003). CONCLUSION: The addition of senna to the bowel preparation protocol with magnesium citrate significantly improves the cleansing outcome. PMID:19360920
Efficacy of prokinetic agents in improving bowel preparation for colonoscopy.
Mishima, Yuko; Amano, Yuji; Okita, Koichi; Takahashi, Yoshiko; Moriyama, Nobuyuki; Ishimura, Norihisa; Furuta, Kenji; Ishihara, Shunji; Adachi, Kyoichi; Kinoshita, Yoshikazu
2008-01-01
Colonoscopy plays an important role in the diagnosis and treatment of gastrointestinal illness in both Western countries and Japan. However, preparative bowel cleansing for colonoscopy is frequently troublesome for elderly and/or constipated patients, since they must drink larger volumes of lavage solution for adequate cleansing. We investigated the use of prokinetic agents for improving the efficacy and tolerability of bowel cleansing prior to colonoscopy. 613 patients were divided into two groups according to oral lavage solution used (polyethylene glycol or magnesium citrate), and were further randomized to receive either vehicle (100 ml water) alone, vehicle with 5 mg mosapride citrate, or vehicle with 50 mg itopride hydrochloride 30 min before administration of lavage solution. Experimental parameters included bowel cleansing quality, times to first defecation and completion of bowel cleansing, and incidence of uncomfortable abdominal symptoms during colonoscopy preparation. Administration of mosapride citrate or itopride hydrochloride prior to oral lavage solution did not significantly improve bowel cleansing quality. However, statistically significantly fewer uncomfortable abdominal symptoms were found in patients who received mosapride citrate or itopride hydrochloride versus vehicle alone. Prokinetic agents effectively decreased the incidence of uncomfortable abdominal symptoms experienced during colonoscopy preparation. Copyright 2008 S. Karger AG, Basel.
Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa
2017-01-01
Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups.
Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa
2017-01-01
Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups. PMID:29184635
Katz, Philip O; Rex, Douglas K; Epstein, Michael; Grandhi, Nav K; Vanner, Stephen; Hookey, Lawrence C; Alderfer, Vivian; Joseph, Raymond E
2013-03-01
Optimal bowel preparation is vital for the efficacy and safety of colonoscopy. The inconvenience, discomfort, required consumption of large volumes of product, and potential adverse effects associated with some bowel preparations deter patients from colonoscopy and may provide inadequate cleansing. A dual-action, non-phosphate, natural orange-flavored, low-volume preparation containing sodium picosulfate and magnesium citrate (P/MC) is currently being reviewed for bowel cleansing. This was a phase 3, randomized, multicenter, assessor-blinded, prespecified non-inferiority, head-to-head study to investigate the efficacy, safety, and tolerability of day-before administration of P/MC vs. 2L polyethylene glycol solution and two 5-mg bisacodyl tablets (2L PEG-3350 and bisacodyl tablets (HalfLytely and Bisacodyl Tablets Bowel Prep Kit)) in adult patients preparing for colonoscopy (SEE CLEAR II Study). The primary objective of the study was to demonstrate the non-inferiority of P/MC to 2L PEG-3350 and bisacodyl tablets in overall colon cleansing using a modified Aronchick scale. In addition, efficacy in the ascending, mid (transverse and descending), and recto-sigmoid segments of colon was evaluated using a modified Ottawa scale. Patient acceptability and tolerability of the bowel preparations were assessed via a standard questionnaire. Safety was assessed based on the monitoring of adverse events (AEs) and meaningful findings on clinical evaluations including physical examinations, vital sign measurements, and electrocardiograms (ECGs). A total of 603 patients were randomized to receive either P/MC (n = 300) or 2L PEG-3350 and bisacodyl tablets (n = 303). Based on the Aronchick scale, successful overall cleansing was similar in patients receiving P/MC (83.0%) and patients receiving 2L PEG-3350 and bisacodyl tablets (79.7%). P/MC demonstrated non-inferiority to 2L PEG-3350 and bisacodyl tablets in overall cleansing of the colon, as measured by the Aronchick scale. Similarly, the efficacy of P/MC, as measured by the Ottawa scale, was non-inferior to 2L PEG-3350 and bisacodyl tablets in cleansing the ascending, mid, and recto-sigmoid segments of the colon. Patient-reported acceptability and tolerability for each item examined on the questionnaire was significantly greater for P/MC compared with 2L PEG-3350 and bisacodyl tablets (P<0.0001).Treatment-emergent AEs related to the bowel preparation reported by 1% of patients receiving P/MC or 2L PEG-3350 and bisacodyl tablets were nausea (3.0% vs. 4.3%), vomiting (1.4% vs. 2.0%), and headache (2.7% vs. 1.7%). No clinically meaningful changes were noted in either treatment arm in data collected from physical examinations, vital sign measurements, and ECGs. When administered as a day-before dose, the bowel cleansing effects of P/MC were non-inferior compared with 2L PEG-3350 and bisacodyl tablets using the clinician-rated Aronchick and Ottawa scales. Treatment acceptability was significantly more favorable in patients receiving P/MC than in patients receiving 2L PEG-3350 and bisacodyl tablets.
Sigler, K; Gásková, D; Chládková, K; Knebl, R; Wimmer, T; Vacata, V; Gebel, J
2003-01-01
An easy-to construct, easy-to-operate standardized system was developed for determining the residual biological contamination of surgical instruments, endoscopes and other medical appliances subjected to hospital cleansing and/or disinfection. It consists of standard-sized pieces of glass, metal or endoscope plastic--dirt carriers--either bare or enclosed in truncated Eppendorf caps to simulate hard-to-access conditions. The surface of the carriers is covered with model dirt simulating biological contamination and the carriers are then affixed to sturdy metal holders. Conventional model dirt were found to peel or flake off the carrier surface, lowering the precision of residual soil determination. A newly developed model dirt consisting of liver mash, lactose and sunflower oil and exhibiting low tendency to peel off surfaces was therefore used. The whole setup was subjected to chemical or enzymic cleansing programs at elevated temperature in hospital washer-disinfectors of two types, and the residual dirt after cleansing was determined by three methods. The method using toxicant-doped dirt that quenches the luminescence of an indicator bacterium Photobacterium phosphoreum gave satisfactory data under laboratory conditions but with hospital-washed samples it exhibited excessive fluctuations caused by bacterium--dirt interactions and by physical influences. Both other methods gave better results but displayed some process sensitivity. The luciferin-luciferase-based ATP bioluminescence assay sometimes gave low or even negative dirt level values and showed a low effect of reduced dirt accessibility on cleansing of metal carriers. The Bradford protein assay showed about equal cleansing efficiency for both easily and poorly accessible carriers after enzymic cleansing. Our system can be used for determining low levels of residual contamination of medical appliances after cleansing/disinfection and assessing the efficiency of commercial washer-disinfectors; its efficiency can be further increased by using a cleansing process-insensitive method for soil detection and quantification.
Vaginal Cleansing Before Cesarean Delivery: A Systematic Review and Meta-analysis.
Caissutti, Claudia; Saccone, Gabriele; Zullo, Fabrizio; Quist-Nelson, Johanna; Felder, Laura; Ciardulli, Andrea; Berghella, Vincenzo
2017-09-01
To assess the efficacy of vaginal cleansing before cesarean delivery in reducing postoperative endometritis. MEDLINE, Ovid, EMBASE, Scopus, Clinicaltrials.gov, and Cochrane Library were searched from their inception to January 2017. Selection criteria included all randomized controlled trials comparing vaginal cleansing (ie, intervention group) with a control group (ie, either placebo or no intervention) in women undergoing cesarean delivery. Any method of vaginal cleansing with any type of antiseptic solution was included. The primary outcome was the incidence of endometritis. Meta-analysis was performed using the random-effects model of DerSimonian and Laird to produce summary treatment effects in terms of relative risk (RR) with 95% CI. Sixteen trials (4,837 women) on vaginal cleansing immediately before cesarean delivery were identified as relevant and included in the review. In most of the included studies, 10% povidone-iodine was used as an intervention. The most common way to perform the vaginal cleansing was the use of a sponge stick for approximately 30 seconds. Women who received vaginal cleansing before cesarean delivery had a significantly lower incidence of endometritis (4.5% compared with 8.8%; RR 0.52, 95% CI 0.37-0.72; 15 studies, 4,726 participants) and of postoperative fever (9.4% compared with 14.9%; RR 0.65, 95% CI 0.50-0.86; 11 studies, 4,098 participants) compared with the control group. In the planned subgroup analyses, the reduction in the incidence of endometritis with vaginal cleansing was limited to women in labor before cesarean delivery (8.1% compared with 13.8%; RR 0.52, 95% CI 0.28-0.97; four studies, 440 participants) or those with ruptured membranes (4.3% compared with 20.1%; RR 0.23, 95% CI 0.10-0.52; three studies, 272 participants). Vaginal cleansing immediately before cesarean delivery in women in labor and in women with ruptured membranes reduces the risk of postoperative endometritis. Because it is generally inexpensive and a simple intervention, we recommend preoperative vaginal preparation before cesarean delivery in these women with sponge stick preparation of povidone-iodine 10% for at least 30 seconds. More data are needed to assess whether this intervention may be also useful for cesarean deliveries performed in women not in labor and for those without ruptured membranes. PROSPERO International prospective register of systematic reviews, https://www.crd.york.ac.uk/PROSPERO/, CRD42017054843.
The Moral Virtue of Authenticity: How Inauthenticity Produces Feelings of Immorality and Impurity.
Gino, Francesca; Kouchaki, Maryam; Galinsky, Adam D
2015-07-01
The five experiments reported here demonstrate that authenticity is directly linked to morality. We found that experiencing inauthenticity, compared with authenticity, consistently led participants to feel more immoral and impure. This link from inauthenticity to feeling immoral produced an increased desire among participants to cleanse themselves and to engage in moral compensation by behaving prosocially. We established the role that impurity played in these effects through mediation and moderation. We found that inauthenticity-induced cleansing and compensatory helping were driven by heightened feelings of impurity rather than by the psychological discomfort of dissonance. Similarly, physically cleansing oneself eliminated the relationship between inauthenticity and prosocial compensation. Finally, we obtained additional evidence for discriminant validity: The observed effects on desire for cleansing were not driven by general negative experiences (i.e., failing a test) but were unique to experiences of inauthenticity. Our results establish that authenticity is a moral state--that being true to thine own self is experienced as a form of virtue. © The Author(s) 2015.
The long-term use of soap does not affect the pH-maintenance mechanism of human skin.
Takagi, Y; Kaneda, K; Miyaki, M; Matsuo, K; Kawada, H; Hosokawa, H
2015-05-01
The pH at the surface of healthy human skin is around 5. Cleansing the skin with soap increases the pH of the skin, which then returns to a more acidic pH within a few hours. However, the effects of skin cleansing with soap over a long time on the pH regulatory system is still unclear. We compared the pH of the skin between users of a soap-based cleanser and of a mild-acidic cleanser prior to and following the cleansing. This study had two groups of subjects, one group who had used a soap-based cleanser for more than 5 years and the other group who had used a mild-acidic cleanser for more than 5 years. The pH on the inner forearm of each subject was measured prior to and for 6 h after cleansing with a soap bar. There were no differences between the pH of the skin these two groups prior to cleansing, immediately after cleansing or in the pH recovery rate for 6 h. These results suggest that long-term continuous use of a soap-based cleanser does not affect the pH-maintaining mechanism of human skin. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Hyper-hydration: a new perspective on wound cleansing, debridement and healing.
2016-06-01
In a recent symposium organised by Hartmann, the involvement of moisture and hydration in healing was re-evaluated and the use of hyper-hydration in promoting healing was examined. The distinction between hyperhydration and maceration was also discussed. Clinical studies were presented to give an overview of the clinical evidence to how Hydro-Responsive Wound Dressings can aid in healing via cleansing, debridement and desloughing of several wound types.
New Eye Cleansing Product Improves Makeup-Related Ocular Problems.
Okura, Masako; Kawashima, Motoko; Katagiri, Mikiyuki; Shirasawa, Takuji; Tsubota, Kazuo
2015-01-01
Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.
New Eye Cleansing Product Improves Makeup-Related Ocular Problems
Okura, Masako; Kawashima, Motoko
2015-01-01
Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms. PMID:26347812
Paranhos, Regina Márcia Zuccolotto Felippe; Batalhão, Carlos Henrique; Semprini, Marisa; Regalo, Simone Cecílio Hallak; Ito, Izabel Yoko; de Mattos, Maria da Glória Chiarello
2007-01-01
In addition to an initial socket discomfort, ocular prosthesis (OP) installation may allow the adherence of fungi and/or bacteria due to the superficial characteristics of the prosthesis’ material, use of inadequate cleansing solutions and methods, or because the void located between the internal portion of the prosthesis and the anophthalmic cavity (AC) mucosa. Objective: The aim of this study was to evaluate OP biofilm formation and the level of contamination of the internal portion of the OP and the AC in 24 patients. Material and Methods: Material was collected from the AC at the beginning of the study and 15 days after cleansing of the OP with 3 cleansing solutions: a neutral liquid soap, a multiuse solution for contact lens (Complete) and 0.12% chlorhexidine (Periogard). The collected materials were sowed in Petri dishes containing selective media for aerobic and facultative microorganisms, specifically staphylococci (Hipersalt agar with egg yolk), aerobic microorganisms (Brain Heart Infusion Blood Agar), streptococci (Mitis salivarius Agar), gram-negative bacilli (MacConkey Agar) and yeasts (Chromagar CandidaTM), incubated at 35°C or 37°C and the number of colony forming units were counted. Data were analyzed statistically by ANOVA, Friedman’s test and Spearman’s correlation. Results: Aerobic microorganisms, gram-negative bacilli and S. aureus were found in the OP biofilm and in the AC. There was statistically significant difference (p<0.05) between the number of microorganisms before and after the use of the cleansing solutions. Conclusion: There was positive correlation with respect to the microorganisms present in the OP biofilm and AC for the 4 proposed treatments, indicating that the decrease of OP contamination leads to AC contamination as well. PMID:19089097
Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging.
Wei, Wei; Ge, Zhi-Zheng; Lu, Hong; Gao, Yun-Jie; Hu, Yun-Biao; Xiao, Shu-Dong
2008-01-01
To evaluate the effects of the various methods of small bowel preparation on the quality of visualization of the small bowel and the gastrointestinal transit time of capsule endoscopy (CE). Ninety patients referred for CE were prospectively randomized to three equal groups according to the preparation used: (a) a control group, in which patients were requested to drink 1 L of clear liquids only, 12 h before the examination; (b) a purgative group, in which patients were requested to ingest 1 L of a polyethylene glycol (PEG)/electrolyte solution only, 12 h before the examination; or (c) a purgative combined with simethicone group (P-S group), in which patients were requested to ingest 1 L of PEG, 12 h before the examination, and 300 mg of simethicone, 20 min before the examination. Effects of the different bowel preparations on the gastric transit time (GTT), small bowel transit time (SBTT), examination completion rate, quality of images of the entire small intestine, and cleansing of the proximal small bowel and distal ileum were evaluated. The number of patients with "adequate" cleansing of the entire small intestine was 17 in the P-S group, 12 in the purgative group, and seven in the control group (P= 0.002). The P-S group had significantly better image quality than the control group (P= 0.001). The P-S group had significantly better image quality for the proximal small bowel (segment A [Seg A]) than the control group (P= 0.0001). Both the P-S group (P= 0.0001) and the purgative group (P= 0.0002) had significantly better image quality for the distal ileum (segment B [Seg B]) than the control group; the P-S group had significantly better image quality than the purgative group as well (P= 0.0121). Gastrointestinal transit time was not different among the three groups, nor was the examination completion rate. Purgative bowel cleansing combined with simethicone before CE improved the quality of imaging of the entire small bowel as well as the visualization of the mucosa in the proximal and distal small intestine.
Pin site care for preventing infections associated with external bone fixators and pins.
Lethaby, Anne; Temple, Jenny; Santy-Tomlinson, Julie
2013-12-03
Metal pins are used to apply skeletal traction or external fixation devices in the management of orthopaedic fractures. These percutaneous pins protrude through the skin, and the way in which they are treated after insertion may affect the incidence of pin site infection. This review set out to summarise the evidence of pin site care on infection rates. To assess the effect on infection rates of different methods of cleansing and dressing orthopaedic percutaneous pin sites. In September 2013, for this third update, we searched the Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We evaluated all randomised controlled trials (RCTs) that compared the effect on infection and other complication rates of different methods of cleansing or dressing orthopaedic percutaneous pin sites. Two review authors independently assessed the citations retrieved by the search strategies for reports of relevant RCTs, then independently selected trials that satisfied the inclusion criteria, extracted data and undertook quality assessment. A total of eleven trials (572 participants) were eligible for inclusion in the review but not all participants contributed data to each comparison. Three trials compared a cleansing regimen (saline, alcohol, hydrogen peroxide or antibacterial soap) with no cleansing (application of a dry dressing), three trials compared alternative sterile cleansing solutions (saline, alcohol, peroxide, povidone iodine), three trials compared methods of cleansing (one trial compared identical pin site care performed daily or weekly and the two others compared sterile with non sterile techniques), one trial compared daily pin site care with no care and six trials compared different dressings (using different solutions/ointments and dry and impregnated gauze or sponges). One small blinded study of 38 patients found that the risk of pin site infection was significantly reduced with polyhexamethylene biguanide (PHMB) gauze when compared to plain gauze (RR 0.23, 95% CI 0.12 to 0.44) (infection rate of 1% in the PHMB group and 4.5% in the control group) but this study was at high risk of bias as the unit of analysis was observations rather than patients. There were no other statistically significant differences between groups in any of the other trials. The available trial evidence was not extensive, was very heterogeneous and generally of poor quality, so there was insufficient evidence to be able to identify a strategy of pin site care that minimises infection rates. Adequately-powered randomised trials are required to examine the effects of different pin care regimens, and co-interventions - such as antibiotic use - and other extraneous factors must be controlled in the study designs.
Repici, A; Cestari, R; Annese, V; Biscaglia, G; Vitetta, E; Minelli, L; Trallori, G; Orselli, S; Andriulli, A; Hassan, C
2012-10-01
Low-volume bowel preparations with polyethylene glycol (PEG) have been shown to provide an equivalent cleansing with improved tolerability as compared with standard PEG bowel preparation for colonoscopy. A new iso-osmotic sulphate-free formulation of PEG-Citrate-Simethicone (PEG-CS) in combination with bisacodyl has been recently developed. To compare the quality of bowel cleansing with PEG-CS with bisacodyl vs. PEG-Ascorbate (PEG-ASC) in adult out-patients undergoing colonoscopy. Randomised, observer-blind, parallel group study in adult out-patients undergoing colonoscopy in five Italian centres. Both preparations were taken the evening before the procedure. Subjects were instructed to take 2-4 tablets of 5 mg bisacodyl at 16:00 hours and 2 L of PEG-CS at 20:00 hours or 2 L of PEG-ASC plus 1 L of additional water the day before colonoscopy. Bowel cleansing was evaluated according to the Boston Bowel Preparation Scale (≥6 scores were considered as 'clinical success'), and mucosal visibility according to a 3-point scale. Tolerability, acceptability and compliance were also evaluated. Four hundred and eight patients were randomly allocated to PEG-CS and bisacodyl (n = 204, male patient 48%, mean age 59.1 years) or PEG-ASC (n = 204, male patient 51%, age 59.4 years). In the planned per-protocol analysis, the rate of successful preparation was 79.1% following PEG-CS with bisacodyl, and 70% following PEG-ASC (P < 0.05). Mucosal visibility was evaluated as optimal in 56.1% in the PEG-CS and bisacodyl and 46.3% in the PEG-ASC group (P < 0.05). There were no serious adverse events (AE) in each of the two experimental groups. Two subjects in the PEG-ASC group discontinued the study because of AE. Polyethylene glycol-Citrate-Simethicone in combination with bisacodyl was more effective for bowel cleansing than PEG-ASC for out-patient colonoscopy. Tolerability, safety, acceptability and compliance of the two low-volume bowel preparations were similar. © 2012 Blackwell Publishing Ltd.
Kierkus, Jaroslaw; Horvath, Andrea; Szychta, Monika; Woynarowski, Marek; Wegner, Agnieszka; Wiernicka, Anna; Dadalski, Maciej; Teisseyre, Mikolaj; Dziechciarz, Piotr
2013-08-01
Many protocols of bowel preparation are available for use in children; however, none of them is commonly accepted. The aim of the study was to evaluate the efficacy and acceptability of high-volume polyethylene glycol (PEG) versus low-volume PEG combined with bisacodyl (BPEG) versus sennosides for colonoscopy preparation in children. Participants ages 10 to 18 years were randomly assigned to receive either PEG 60 or PEG 30 mL kg⁻¹ day⁻¹ plus oral bisacodyl 10 to 15 mg/day or sennosides 2 mg kg⁻¹ day⁻¹ for 2 days. A blinded assessment of bowel cleansing was made by the endoscopist according to the Aronchick and Ottawa scales. Patient acceptability was evaluated with the visual-analog scale. Analysis was done on an available case analysis basis. Of 240 patients enrolled in the study 234 patients were available for analysis of the efficacy of colon cleansing. There were no significant differences found among the 3 groups for the proportions of participants with excellent/good (PEG: 35/79, BPEG: 26/79, sennosides 25/76) and poor/inadequate (PEG: 20/79, BPEG: 28/79, sennosides 28/76) bowel preparation evaluated with the Aronchick scale and for the mean Ottawa total score (PEG: 5.47 ± 3.63, BPEG: 6.22 ± 3.3, sennosides: 6.18 ± 3.53). Acceptability of bowel cleansing protocol was similar in all of the groups (P = 0.8). All 3 cleansing methods showed similar efficacy and tolerability; however, none of them was satisfactory.
Radaelli, Franco; Meucci, Gianmichele; Imperiali, Gianni; Spinzi, Giancarlo; Strocchi, Enrico; Terruzzi, Vittorio; Minoli, Giorgio
2005-12-01
To compare the efficacy and patient acceptance of an oral high dose of senna to conventional polyethylene glycol-electrolyte lavage solution (PEG-ES) in adults undergoing elective colonoscopy. Consecutive outpatients referred for elective colonoscopy were prospectively randomly assigned to receive, the day before the procedure, either 24 tablets of 12 mg senna, divided into two doses at 1 p.m. and 9 p.m. (senna group, n=191), or standard 4-L PEG-ES (PEG-ES group, n=92). The overall quality of colon cleansing (primary outcome measure) and cleansing in the right colon were evaluated using the Aronchick scoring scale (1=excellent to 4=inadequate) by the investigator/endoscopist who was blinded to the treatment assignment. Patient acceptance and the safety of the preparation were assessed by a nurse, using a structured questionnaire covering compliance with the dosing, overall tolerance of the preparation (1=none or mild discomfort to 4=severely distressing), and adverse events. The quality of colon cleansing, overall tolerance of the preparation, and compliance were significantly better with senna; overall cleansing was excellent or good in 90.6% of patients in the senna group and in 79.7% in the PEG-ES group (p= 0.003). The percentage of procedures rescheduled because of insufficient colon cleansing was 7.3% in the PEG-ES group and 2.6% in the senna group (p=0.035). Multivariate logistic regression modeling showed the PEG-ES preparation as negative independent predictor of unsuccessful bowel cleansing. The incidence of adverse reactions was similar in the two groups; patients who received senna experienced significantly less nausea and vomiting, but more abdominal pain. An oral high dose of senna is a valid alternative to standard PEG-ES for outpatient colonoscopy preparation.
Efficacy and safety of sodium phosphate for colon cleansing in type 2 diabetes mellitus.
Ozturk, Nevin Akcaer; Gokturk, Huseyin Savas; Demir, Mehmet; Unler, Gulhan Kanat; Gur, Gurden; Yilmaz, Ugur
2010-11-01
The need for colonoscopy is common among diabetic patients. However, there are no standards per se for bowel preparation in patients with type 2 diabetes. In this study, we evaluated the efficacy, safety, and tolerability of sodium phosphate (NaP), and the quality of bowel cleansing in relation to glycemic control and late complications. A total of 50 consecutive type 2 diabetic patients and 50 non-diabetic patients underwent bowel preparation by NaP. Fasting blood glucose, sodium (Na), potassium (K), calcium (Ca), phosphorus (P), magnesium, and creatinine levels were measured on the procedure day. Patients were given a tolerability questionnaire regarding symptoms. With regard to bowel preparation quality, optimal bowel cleansing was achieved in 35 (70%) diabetic and 47 (94%) non-diabetic patients (P = 0.002). Abdominal pain or discomfort during and an hour after the procedure was similar in both groups (P >0.05). The changes in Na, K, Ca, P and creatinine levels after NaP use did not reach statistical significance between the groups (P >0.05). In the diabetic patients, there was a significant correlation between the quality of bowel cleansing and mean age, duration of diabetes mellitus, level of hemoglobin A1c (HbA1c), fasting blood glucose level, and diabetic late complications (P <0.05). These data suggest that NaP is safe and tolerable in diabetic patients, but the quality of bowel cleansing is worse than in non-diabetic patients. These observations support the concept that the quality of bowel cleansing in those with type 2 diabetes is closely related to the duration and regulation of the disease and the presence of late complications.
Ell, C; Fischbach, W; Keller, R; Dehe, M; Mayer, G; Schneider, B; Albrecht, U; Schuette, W
2003-04-01
There are conflicting data regarding the optimal bowel preparation for colonoscopy. This study was carried out to compare the efficacy, safety, and tolerability of three widely used bowel lavage solutions: the standard polyethylene glycol-electrolyte solution based on the GoLytely formulation (PEG-EL1; Klean-Prep); a sulphate-free PEG-EL solution based on the NuLytely formulation (PEG-EL2, Endofalk); and a sodium phosphate preparation (NaP, Fleet Phospho-Soda). A total of 185 consecutive patients scheduled for elective colonoscopy were prospectively randomly assigned to undergo pre-colonoscopic bowel cleansing with either 4 l of PEG-EL1 (n=64), 3 l of PEG-EL2 (n=59), or 90 ml of NaP (n=62). The quality of preparatory colonic cleansing for each segment from the rectum to the ascending colon was scored on a five-level rating scale (1, very good to 5, very poor) by endoscopists who were blinded with regard to the type of preparation used. The primary outcome measure for the comparison of treatments was the "worst" score in any of the rated bowel segments. Safety and tolerability were evaluated by means of a symptom questionnaire completed by each patient immediately before the procedure. Of the 185 patients who were randomly assigned to one of the three treatments, 175 underwent colonoscopy and 173 were evaluable with regard to efficacy - 59, 54, and 60 patients treated with PEG-EL1, PEG-EL2, and NaP, respectively. The treatment groups were comparable with regard to the baseline characteristics. PEG-EL1 was statistically significantly superior to the other treatments in relation to the "worst cleansing" score ( P=0.003). In addition, colonoscopic visualization was markedly better in each of the five bowel segments and general "very good" or "good" ratings were achieved in more than 90 % of patients treated with PEG-EL1. The percentages were consistently lower in the other two groups, particularly in the ascending colon. With the exception of the sigmoid, the differences in all segments of the large bowel were statistically significant (P=0.04). Patient satisfaction was comparable between the treatment groups. Adverse events (mainly nausea/vomiting and abdominal pain) and deviations in laboratory values occurred more frequently in the NaP group. Preparatory PEG-EL1 (Klean-Prep) was significantly superior to PEG-EL2 (Endofalk) and NaP (Fleet Phospho-Soda) in achieving effective cleansing of the entire colon prior to colonoscopy. On the basis of these data, PEG-EL1 can be regarded as the "gold standard" for bowel cleansing prior to colonoscopy.
Effectiveness of Sodium Picosulfate/Magnesium Citrate (PICO) for Colonoscopy Preparation
Suh, Wu Seok; Jeong, Jin Sik; Kim, Dong Sik; Kim, Sang Woo; Kwak, Dong Min; Hwang, Jong Seong; Kim, Hyun Jin; Park, Man Woo; Shim, Min Chul; Koo, Ja-Il; Kim, Jae Hwang; Shon, Dae Ho
2014-01-01
Purpose Bowel preparation with sodium phosphate was recently prohibited by the U.S. Food and Drug Administration. Polyethylene glycol (PEG) is safe and effective; however, it is difficult to drink. To identify an easy bowel preparation method for colonoscopy, we evaluated three different bowel preparation regimens regarding their efficacy and patient satisfaction. Methods In this randomized, comparative study, 892 patients who visited a secondary referral hospital for a colonoscopy between November 2012 and February 2013 were enrolled. Three regimens were evaluated: three packets of sodium picosulfate/magnesium citrate (PICO, group A), two packets of PICO with 1 L of PEG (PICO + PEG 1 L, group B), and two packets of PICO with 2 L of PEG (PICO + PEG 2 L, group C). A questionnaire survey regarding the patients' preference for the bowel preparation regimen and satisfaction was conducted before the colonoscopies. The quality of bowel cleansing was scored by the colonoscopists who used the Aronchick scoring scale and the Ottawa scale. Results The patients' satisfaction rate regarding the regimens were 72% in group A, 64% in group B, and 45.9% in group C. Nausea and abdominal bloating caused by the regimens were more frequent in group C than in group A or group B (P < 0.01). Group C showed the lowest preference rate compared to the other groups (P < 0.01). Group C showed better right colon cleansing efficacy than group A or group B. Conclusion Group A exhibited a better result than group B or group C in patient satisfaction and preference. In the cleansing quality, no difference was noted between groups A and C. PMID:25360429
Amato, Arnaldo; Radaelli, Franco; Paggi, Silvia; Terruzzi, Vittorio
2010-03-01
Patients' compliance with and tolerance of large-volume polyethylene glycol electrolyte solution (PEG-ES) have prompted continuous investigation with alternative forms of cleansing. High-dose senna is superior to PEG-ES for the quality of bowel cleansing, patient compliance, and tolerance, but its acceptance may be influenced by the incidence of abdominal pain. We hypothesized that a combination of half doses of PEG-ES and senna could minimize the incidence of abdominal pain without affecting the quality of bowel preparation. This randomized, investigator-blinded trial has been conducted on consecutive outpatients scheduled for elective colonoscopy at a single community-based hospital. Patients were randomly assigned to receive either 12 tablets of 12 mg senna and 2 l of PEG-ES (half-dose group, HDG) or 24 tablets of senna divided in two doses (senna group, SG) the day before colonoscopy. The main outcome measures were the quality of colon cleansing (Aronchick scoring scale) and the incidence of preparation-related abdominal pain. Secondary outcome measures were patients' compliance with the cleansing regimen, overall tolerability, prevalence of predefined side effects, and quality of right colon cleansing. A total of 296 patients were enrolled (HDG=151 and SG=145). Overall cleansing was excellent to good in 90.1 and 88.3% patients in HDG and SG, respectively (P=0.62). Preparation-related moderate-to-severe abdominal pain was reported by 6% patients in HDG and 15.2% in SG (P=0.009). No significant differences were observed for secondary outcomes. The regimen combining half doses of PEG-ES and senna provides high-quality bowel preparation and acceptable patient tolerance, with less abdominal pain compared with high-dose senna.
Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N
2017-01-01
AIM To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. METHODS Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. RESULTS Out of 439 citations, 4 trials fulfilled our inclusion criteria (n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). CONCLUSION In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population. PMID:28932092
Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N
2017-08-28
To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. Out of 439 citations, 4 trials fulfilled our inclusion criteria ( n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population.
Grosman, Mònica D; Mosquera, Vanesa M; Hernandez, Maria G; Agostini, Silvana; Adragna, Marta; Sojo, Ernesto T
2005-01-01
In a previous communication, we demonstrated that, in the prevention of exit-site infection (ESI) in children, the cleansing agent 50% Amuchina (electrolytic chloroxidizer. Amuchina SpA, Genoa, Italy) is more effective than 10% povidone iodine and as effective as 4% chlorhexidine, but with fewer adverse secondary effects. In the present study, we assessed, in an Argentine pediatric population, whether Amuchina 3% is as effective as Amuchina 50% in preventing ESI in children on chronic peritoneal dialysis. In an open-label, single-center prospective study, 27 children (mean age: 7.2 years; range: 1.7-17 years) used 3% Amuchina as a cleansing agent for the daily care of a healthy exit site. Of the 27 children, 14 were switched from 50% Amuchina to 3% Amuchina, and 13 were using the 3% Amuchina for the first time. The control group consisted of 18 patients who had previously used 50% Amuchina as a cleansing agent. We followed the recommendations of the International Society for Peritoneal Dialysis with regard to exit-site care, which include keeping the cleansing agent out of the sinus and rinsing the exit site with sterile water. Amuchina was used from the first post-implantation care of the exit site. No adverse secondary effects were seen with the use of Amuchina at either concentration. Patients using 3% Amuchina presented an ESI rate similar to that of patients using Amuchina 50%. The cost of 3% Amuchina was significantly lower than that of the 50% concentration, and it was even lower than the cost for 10% povidone iodine or 4% chlorhexidine. Although more research trials are needed to assess the efficacy of 3% Amuchina, we conclude that 3% Amuchina is the best and most cost-effective cleansing agent for the daily care of a healthy exit site in children on chronic peritoneal dialysis.
Gruss, H-J; Cockett, A; Leicester, R J
2012-01-01
With the availability of several bowel cleansing agents, physicians and hospitals performing colonoscopies will often base their choice of cleansing agent purely on acquisition cost. Therefore, an easy to use budget impact model has been developed and established as a tool to compare total colon preparation costs between different established bowel cleansing agents. The model was programmed in Excel and designed as a questionnaire evaluating information on treatment costs for a range of established bowel cleansing products. The sum of costs is based on National Health Service reference costs for bowel cleansing products. Estimations are made for savings achievable when using a 2-litre polyethylene glycol with ascorbate components solution (PEG+ASC) in place of other bowel cleansing solutions. Test data were entered into the model to confirm validity and sensitivity. The model was then applied to a set of audit cost data from a major hospital colonoscopy unit in the UK. Descriptive analysis of the test data showed that the main cost drivers in the colonoscopy process are the procedure costs and costs for bed days rather than drug acquisition costs, irrespective of the cleansing agent. Audit data from a colonoscopy unit in the UK confirmed the finding with a saving of £107,000 per year in favour of PEG+ASC when compared to sodium picosulphate with magnesium citrate solution (NaPic+MgCit). For every patient group the model calculated overall cost savings. This was irrespective of the higher drug expenditure associated with the use of PEG+ASC for bowel preparation. Savings were mainly realized through reduced costs for repeat colonoscopy procedures and associated costs, such as inpatient length of stay. The budget impact model demonstrated that the primary cost driver was the procedure cost for colonoscopy. Savings can be realized through the use of PEG+ASC despite higher drug acquisition costs relative to the comparator products. From a global hospital funding perspective, the acquisition costs of bowel preparations should not be used as the primary reason to select the preferred treatment agent, but should be part of the consideration, with an emphasis on the clinical outcome.
Prolonged toxicity from Kambo cleansing ritual.
Li, Kai; Horng, Howard; Lynch, Kara; Smollin, Craig G
2018-04-02
Kambo cleanse is a purification, cleansing ritual traditionally performed by South American shaman to confer luck and health to hunters. We report a patient who presented to the emergency department with prolonged symptoms of vomiting, flushing, facial swelling, altered mental status, and agitation requiring chemical restraints, 22 h after a Kambo cleanse. The patient was found with four small, circular, superficial burns to the ankle at the site where the resin was introduced. The cleanse consists of rubbing resin obtained from the secretions of the giant leaf frog (Phyllomedusa bicolor) into superficial wounds to produce intense gastrointestinal symptoms followed by a sensation of increased stamina and strength. The cleanse is now being increasingly performed in Europe and USA.
Cleansing technique using high-velocity steam-air micromist jet spray.
Fukuda, Koichi; Ishihara, Masayuki; Murakami, Kaoru; Nakamura, Shingo; Sato, Yoko; Kuwabara, Masahiro; Fujita, Masanori; Kiyosawa, Tomoharu; Yokoe, Hidetaka
2017-10-01
Application of a high-velocity steam-air micromist jet spray (HVS-AMJS; micromist average diameter: 2.4 μm) for cleansing the skin is proposed. Low-pressure steam is mixed with compressed air (pH 6.5) in a nozzle, and then sprayed at a pressure of ≦0.25 MPa and a velocity of ≧0.34 m/s on the skin or surface of material located approximately 5-10 cm from the nozzle. The temperature on the sprayed surface and water flow rate could be controlled between 42 °C and 46 °C and at approximately 50 mL/min, respectively. Compared with ultrasonic cleansing with tap water and rubbing with only tap water, the HVS-AMJS successfully removed fluorescent lotion covering pieces of wood and significantly reduced both the number of coliforms and the total viable counts on pieces of wood and gauze. Furthermore, the HVS-AMJS effectively removed oily ink from the skin of hairless rats, and temporarily elevated the skin temperature and blood flow, indicating massage effects. The striking characteristics of this cleansing technique using HVS-AMJS are not only its ability to remove microbes and residue without using any chemicals or detergents but also its massage effects.
Morality and soap in engineers and social scientists: the Macbeth effect interacts with professions.
Schaefer, Michael
2017-11-07
Several studies demonstrate that physical cleansing is actually efficacious to cope with threatened morality, thus demonstrating that physical and moral purity are psychologically interwoven. This so-called Macbeth effect has been explained, for example, by the conceptual metaphor theory that suggests an embodiment of the moral purity metaphor. Recent research draws attention to individual differences when using conceptual metaphors. The present study shows that the moral purity link interacts with different professions. Engineering and social science students were asked to hand copy a text in which the protagonist behaved in an immoral way (or in a moral way, control condition). Subsequently, they had to rate cleansing and other products. Both groups of participants showed higher ratings for cleansing products when hand copying the unethical story, but this Macbeth effect was significantly stronger for the group of engineering students. The results demonstrate that the Macbeth effect interacts with individual differences of the chosen profession. The outcome is discussed in terms of recent theories on individual differences in disgust sensitivity.
Adjuncts to colonic cleansing before colonoscopy.
Park, Sanghoon; Lim, Yun Jeong
2014-03-21
Pre-procedural cleansing of the bowel can maximize the effectiveness and efficiency of colonoscopy. Yet, efficacy of the current gold standard colonic preparation method - high-volume oral administration of purgative agents 12-24 h prior to the procedure - is limited by several factors, such as patient compliance (due to poor palatability and inconvenience of the dosing regimen) and risks of complications (due to drug interactions or intolerance). Attempts to resolve these limitations have included providing adjunctive agents and methods to promote the colonic cleansing ability of the principal purgative agent, with the aim of lessening unpleasant side effects (such as bloating) and reducing the large ingested volume requirement. Several promising adjunctive agents are bisacodyl, magnesium citrate, senna, simethicone, metoclopramide, and prokinetics, and each are being investigated for their potential. This review provides an up to date summary of the reported investigations into the potencies and weaknesses of the key adjuncts currently being applied in clinic as supplements to the traditional bowel preparation agents. While the comparative analysis of these adjuncts showed that no single agent or method has yet achieved the goal of completely overcoming the limitations of the current gold standard preparation method, they at least provide endoscopists with an array of alternatives to help improve the suboptimal efficacy of the main cleansing solutions when used alone. To aid in this clinical endeavor, a subjective grade was assigned to each adjunct to indicate its practical value. In addition, the systematic review of the currently available agents and methods provides insight into the features of each that may be overcome or exploited to create novel drugs and strategies that may become adopted as effective bowel cleansing adjuncts or alternatives.
Adjuncts to colonic cleansing before colonoscopy
Park, Sanghoon; Lim, Yun Jeong
2014-01-01
Pre-procedural cleansing of the bowel can maximize the effectiveness and efficiency of colonoscopy. Yet, efficacy of the current gold standard colonic preparation method - high-volume oral administration of purgative agents 12-24 h prior to the procedure - is limited by several factors, such as patient compliance (due to poor palatability and inconvenience of the dosing regimen) and risks of complications (due to drug interactions or intolerance). Attempts to resolve these limitations have included providing adjunctive agents and methods to promote the colonic cleansing ability of the principal purgative agent, with the aim of lessening unpleasant side effects (such as bloating) and reducing the large ingested volume requirement. Several promising adjunctive agents are bisacodyl, magnesium citrate, senna, simethicone, metoclopramide, and prokinetics, and each are being investigated for their potential. This review provides an up to date summary of the reported investigations into the potencies and weaknesses of the key adjuncts currently being applied in clinic as supplements to the traditional bowel preparation agents. While the comparative analysis of these adjuncts showed that no single agent or method has yet achieved the goal of completely overcoming the limitations of the current gold standard preparation method, they at least provide endoscopists with an array of alternatives to help improve the suboptimal efficacy of the main cleansing solutions when used alone. To aid in this clinical endeavor, a subjective grade was assigned to each adjunct to indicate its practical value. In addition, the systematic review of the currently available agents and methods provides insight into the features of each that may be overcome or exploited to create novel drugs and strategies that may become adopted as effective bowel cleansing adjuncts or alternatives. PMID:24659864
Gfatter, R; Hackl, P; Braun, F
1997-01-01
In adults the influence of cleansing preparations on the pH, fat content and hydration of the skin is well documented. Studies in newborn and small infants have not been reported. Our study aimed at examining whether similar effects can be ascertained in infants. Infants without skin disease, aged 2 weeks to 16 months, entered an open, controlled and randomized study. Ten infants each had skin washed with tap water (control group), liquid detergent (pH 5.5), compact detergent (pH 5.5) or alkaline soap (pH 9.5). The pH, fat content and hydration were measured before and 10 min after cleansing. Findings were statistically evaluated by parametric covariance analysis. The skin pH increased from an average of 6.60 after cleansing in all groups. The smallest increase (+0.19) was observed in the control group, the largest (+0.45) after washing with alkaline soap. After treatment with liquid or compact detergent, the increase of the pH was only 0.09 higher than for the control group. In comparison to the compact and liquid detergents, the alkaline soap group had a significantly higher increase in pH. The fat content (mean starting value: 4.34 micrograms/cm2) decreased after washing in all groups; the smallest effect was observed in the control group (decrease of 0.93 micrograms/cm2), the highest for the alkaline soap group (decrease of 4.81 micrograms/cm2). In comparison to the compact and liquid detergents, the alkaline soap group had a higher decrease in fat content. This difference was significant for compact detergents. No statistically significant differences were observed for hydration before versus after washing. Each cleansing agent, even normal tap water, influences the skin surface. The increase of the skin pH irritates the physiological protective 'acid mantle', changes the composition of the cutaneous bacterial flora and the activity of enzymes in the upper epidermis, which have an acid pH optimum. The dissolution of fat from the skin surface may influence the hydration status leading to a dry and squamous skin.
Woo, Kevin Y
2015-07-01
The purpose of this study was to examine the mediating effect of anxiety in the relationship between anticipation and pain in people with chronic wounds. Pain is common in people with chronic wounds. Anticipation or negative expectation of discomfort has been shown to have an augmenting effect on pain; also known as nocebo hyperalgesia. This was a cross-sectional study with repeated measures. Prior to dressing change, anticipatory pain level was evaluated by a 11-point numerical rating scale and anxiety by the Six-items State-Trait Anxiety Inventory (STAI-6). During wound dressing changes, pain was measured before dressing removal, at dressing removal, at cleansing and dressing application using the numerical scale. Analysis was completed based on the data from a convenience sample of 96 patients. Participants reported more pain at cleansing and dressing removal than baseline. High levels of anticipation, anxiety and pain at dressing change for wounds were related to heavy exudate and wound that were covered with necrotic tissue. Finally, the relationship between anticipation and pain perception was mediated by anxiety. Anticipation of pain triggers anxiety that can lead to increased pain. There is a need to incorporate evaluation of anxiety and personal expectations as part of comprehensive pain assessment. Clinicians should be aware of the impact of emotions and anticipation on overall pain experience. © 2015 John Wiley & Sons Ltd.
Colon Cleansing: Is It Helpful or Harmful?
... https://naturalmedicines.therapeuticresearch.com. Accessed March 31, 2018. Detoxes and cleanses. National Center for Complementary and Integrative Health. https://nccih.nih.gov/health/detoxes-cleanses. Accessed March 29, 2018. Mishori R, et ...
Mullany, Luke C; Saha, Samir K; Shah, Rasheduzzaman; Islam, Mohammad Shahidul; Rahman, Mostafiz; Islam, Maksuda; Talukder, Radwanur Rahman; El Arifeen, Shams; Darmstadt, Gary L; Baqui, Abdullah H
2012-05-01
Randomized trials from South Asia indicate umbilical cord chlorhexidine cleansing reduces mortality and omphalitis. No community-based data are available on bacteriological profile of the cord, early neonatal colonization dynamics, or impact of cord cleansing on colonizing organisms. Such data could clarify the design of scaled chlorhexidine interventions. Umbilical swabs were collected at home (days 1, 3, 6) after birth from infants participating in a trial of 3 cord-care regimens (no chlorhexidine, single cleansing, multiple cleansing) in Sylhet, Bangladesh. Overall and organism-specific positivity rates were estimated by cord-care regimen and by day of collection. Between September 2008 and October 2009, 1923 infants contributed 5234 umbilical swabs. Positivity rate was high (4057 of 5234, 77.5%) and varied substantially across groups. Immediate (day 1) reductions in cord colonization were observed in single- (prevalence rate ratio = 0.75, 95% confidence interval: 0.70-0.81) and multiple- (prevalence rate ratio = 0.71, 95% confidence interval: 0.66-0.77) cleansing groups. Reductions persisted and increased in magnitude through day 6 only if babies received multiple applications. On days 1, 3, and 6, respectively, multiple cleansing consistently reduced invasive organisms such as Escherichia coli (49%, 64%, and 42% lower), Klebsiella pneumoniae (46%, 53%, and 33% lower), and Staphylococcus aureus (34%, 84%, and 85% lower). Cord cleansing with 4.0% chlorhexidine immediately after birth reduces overall and organism-specific colonization of the stump. Reductions are greater and sustained longer with daily cleansing through the first week of life, suggesting that programs promoting chlorhexidine cleansing should favor multiple over single applications.
Oral purgative and simethicone before small bowel capsule endoscopy
Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José
2013-01-01
AIM: To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. METHODS: Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. RESULTS: There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered to have poor small bowel cleansing (P = 0.417), with significant fluid or debris such that the examination was unreliable. The proportion of patients with a significant amount of bubbles was 50% in Group A, 27.8% in Group B and 15.8% in Group C (P = 0.065). This was significantly lower in Group C when compared to Group A (P = 0.026). The mean GET was 27.8 min for Group A, 27.2 min for Group B and 40.7 min for Group C (P = 0.381). The mean SBTT was 256.4 min for Group A, 256.1 min for Group B and 258.1 min for Group C (P = 0.998). Regarding to the rate of complete examinations, the capsule reached the cecum in 20 patients (100%) in Group A, 16 patients (88.9%) in Group B and 17 patients (89.5%) in Group C (P = 0.312). A definite diagnosis based on relevant small bowel endoscopic lesions was established in 60% of the patients in Group A (12 patients), 44.4% in Group B (8 patients) and 57.8% in Group C (11 patients) (P = 0.587). CONCLUSION: Preparation with 2 L of PEG before small bowel capsule endoscopy (SBCE) may improve small bowel cleansing and the quality of visualization. Simethicone may further reduce intraluminal bubbles. No significant differences were found regarding GET, SBTT and the proportion of complete exploration or diagnostic yield among the three different cleansing protocols. PMID:23424190
Oral purgative and simethicone before small bowel capsule endoscopy.
Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José
2013-02-16
To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered to have poor small bowel cleansing (P = 0.417), with significant fluid or debris such that the examination was unreliable. The proportion of patients with a significant amount of bubbles was 50% in Group A, 27.8% in Group B and 15.8% in Group C (P = 0.065). This was significantly lower in Group C when compared to Group A (P = 0.026). The mean GET was 27.8 min for Group A, 27.2 min for Group B and 40.7 min for Group C (P = 0.381). The mean SBTT was 256.4 min for Group A, 256.1 min for Group B and 258.1 min for Group C (P = 0.998). Regarding to the rate of complete examinations, the capsule reached the cecum in 20 patients (100%) in Group A, 16 patients (88.9%) in Group B and 17 patients (89.5%) in Group C (P = 0.312). A definite diagnosis based on relevant small bowel endoscopic lesions was established in 60% of the patients in Group A (12 patients), 44.4% in Group B (8 patients) and 57.8% in Group C (11 patients) (P = 0.587). Preparation with 2 L of PEG before small bowel capsule endoscopy (SBCE) may improve small bowel cleansing and the quality of visualization. Simethicone may further reduce intraluminal bubbles. No significant differences were found regarding GET, SBTT and the proportion of complete exploration or diagnostic yield among the three different cleansing protocols.
Bowel cleansing before colonoscopy: Balancing efficacy, safety, cost and patient tolerance
Harrison, Nicole M; Hjelkrem, Michael C
2016-01-01
Effective colorectal cancer screening relies on reliable colonoscopy findings which are themselves dependent on adequate bowel cleansing. Research has consistently demonstrated that inadequate bowel preparation adversely affects the adenoma detection rate and leads gastroenterologists to recommend earlier follow up than is consistent with published guidelines. Poor preparation affects as many as 30% of colonoscopies and contributes to an increased cost of colonoscopies. Patient tolerability is strongly affected by the preparation chosen and manner in which it is administered. Poor tolerability is, in turn, associated with lower quality bowel preparations. Recently, several new developments in both agents being used for bowel preparation and in the timing of administration have brought endoscopists closer to achieving the goal of effective, reliable, safe, and tolerable regimens. Historically, large volume preparations given in a single dose were administered to patients in order to achieve adequate bowel cleansing. These were poorly tolerated, and the unpleasant taste of and significant side effects produced by these large volume regimens contributed significantly to patients’ inability to reliably complete the preparation and to a reluctance to repeat the procedure. Smaller volumes, including preparations that are administered as tablets to be consumed with water, given as split doses have significantly improved both the patient experience and efficacy, and an appreciation of the importance of the preparation to colonoscopy interval have produced additional cleansing. PMID:26788258
Maenthaisong, Ratree; Viyoch, Jarupa; Chaiyakunapruk, Nathorn; Warnnissorn, Prateep
2007-09-01
Cleansing lotion containing extract of tamarind fruit pulp was developed to provide skin a lighter effect. Skin irritation may occur due to keratolytic effect of alpha-hydroxyl acids (AHA) in the tamarind fruit pulp extract. To assess the cumulative irritation effect of cleansing lotion containing tamarind fruit extract with 2% (w/w) tartaric acid on human skin compared with placebo product and de-ionized water. The study design was a single-blinded, randomized side of arm, and controlled study. Three samples, including test product, placebo product, and de-ionized water, were repeatedly applied on the inner forearm of 15 healthy females (aged 28.3 +/- 3.1 years) for 30 min daily for 5 days under semi-occlusive patch. Skin irritation was measured by using visual scoring and instruments such as Tewameter and Mexameter. All measurements were done before application of samples every day from day 1 until day 5. Final measurements were done after the last application for 3 days (day 8). The results obtained from the visual scoring scale indicated no irritation signs and symptoms of test product. Mean differences of transepidermal water loss and erythema values between test product and de-ionized water and between test and placebo products were not statistically significant (P > 0.05). These findings indicate a preliminary safety evidence of our developed cleansing lotion containing the natural AHAs and can be used as cumulative evidence for supporting the future home use study of this product in human.
Lee, Seung-Hwa; Kim, Kwang-Min; Seo, Sang-Wook; Kang, Joon-Koo; Lee, Eun-Hye; Lee, Dong-Ryul
2014-01-01
Purpose Bowel cleansing is generally regarded as time-consuming and unpleasant among patients. Patients commonly state that bowel preparation provokes more discomfort than the actual colonoscopic examination. The purpose of this study was to compare two regimens of sodium phosphate (NaP) tablets versus polyethylene glycol (PEG) solution for bowel preparation in healthy Korean adults. Materials and Methods This was a single center, prospective, open-label, investigator-blinded, randomized, controlled-pilot study. A total of 62 healthy Korean subjects were randomly assigned to two groups (NaP vs. PEG). Efficacy, safety, and patient-related outcomes, as well as procedural parameters, were evaluated. Results Although there were no significant differences in total Ottawa bowel quality score, fluid scores and the rate of adequate bowel preparation were significantly better in the NaP group than the PEG group. Additionally, the NaP group showed better results regarding patient tolerance, satisfaction, preference, and rate of adverse events than the PEG group. Significant fluctuations in specific serum electrolytes were common and of a greater magnitude in the NaP group than the PEG group. However, these abnormalities were transient and did not result in serious complications and side effects. Conclusion In this study, NaP tablets were shown to be an effective, well-tolerated, and acceptable regimen for bowel preparation. Also, our study suggests that NaP tablets may be safe and can be used as a bowel cleansing agent in healthy adults undergoing elective colonoscopy. Further multicenter, large scale studies are needed to confirm these findings. PMID:25323890
Cosmetic Cleansing Oil Absorption by Soft Contact Lenses in Dry and Wet Conditions.
Tsukiyama, Junko; Miyamoto, Yuko; Kodama, Aya; Fukuda, Masahiko; Shimomura, Yoshikazu
2017-09-01
Previous reports showed that cosmetic cleansing oil for removing makeup, which contains mineral oil and surfactant, can deform some silicone hydrogel contact lenses (SHCLs) when applied directly to the lenses, although plasma-coated SHCLs (lotrafilcon A and B) were not affected. In the present study, we investigated hydrogel lenses and SHCLs in both wet and dry conditions. Several brands of hydrogel and SHCLs were immersed in a cleansing oil solution containing Sudan Black B for 5 min under wet and dry conditions. The lenses under the wet condition were simply picked up from the saline, whereas those under the dry condition were blotted with paper wipes. After immersing, the excess solution remaining on the lenses was removed by finger rubbing with a multipurpose solution. The lenses were then examined using a stereomicroscope, and their mean brightness was measured and compared. The cosmetic cleansing oil was not absorbed by the hydrogel lenses under wet or dry conditions. However, four of seven brands of SHCLs absorbed the cosmetic cleansing oil under both conditions (dry and wet), whereas asmofilcon A absorbed it only under the dry condition. Lotrafilcon B and delefilcon A did not absorb cleansing oil even under the dry condition. Hydrogel lenses resist cosmetic cleansing oil. However, SHCLs have different degrees of resistance depending on the lens material. Some SHCLs absorbed cosmetic cleansing oil more under dry conditions than under wet conditions.
Bowel preparations for colonoscopy: an RCT.
Di Nardo, Giovanni; Aloi, Marina; Cucchiara, Salvatore; Spada, Cristiano; Hassan, Cesare; Civitelli, Fortunata; Nuti, Federica; Ziparo, Chiara; Pession, Andrea; Lima, Mario; La Torre, Giuseppe; Oliva, Salvatore
2014-08-01
The ideal preparation regimen for pediatric colonoscopy remains elusive, and available preparations continue to represent a challenge for children. The aim of this study was to compare the efficacy, safety, tolerability, and acceptance of 4 methods of bowel cleansing before colonoscopy in children. This randomized, investigator-blinded, noninferiority trial enrolled all children aged 2 to 18 years undergoing elective colonoscopy in a referral center for pediatric gastroenterology. Patients were randomly assigned to receive polyethylene glycol (PEG) 4000 with simethicon (PEG-ELS group) or PEG-4000 with citrates and simethicone plus bisacodyl (PEG-CS+Bisacodyl group), or PEG 3350 with ascorbic acid (PEG-Asc group), or sodium picosulfate plus magnesium oxide and citric acid (NaPico+MgCit group). Bowel cleansing was evaluated according to the Boston Bowel Preparation Scale. The primary end point was overall colon cleansing. Tolerability, acceptability, and compliance were also evaluated. Two hundred ninety-nine patients were randomly allocated to the 4 groups. In the per-protocol analysis, PEG-CS+Bisacodyl, PEG-Asc, and NaPico+MgCit were noninferior to PEG-ELS in bowel-cleansing efficacy of both the whole colon (P = .910) and colonic segments. No serious adverse events occurred in any group. Rates of tolerability, acceptability, and compliance were significantly higher in the NaPico+MgCit group. Low-volume PEG preparations (PEG-CS+Bisacodyl, PEG-Asc) and NaPico+MgCit are noninferior to PEG-ELS in children, representing an attractive alternative to high-volume regimens in clinical practice. Because of the higher tolerability and acceptability profile, NaPico+MgCit would appear as the most suitable regimen for bowel preparation in children. Copyright © 2014 by the American Academy of Pediatrics.
Hookey, Lawrence C; Depew, William T; Vanner, Stephen J
2006-01-01
INTRODUCTION The effectiveness of polyethylene glycol solutions (PEG) for colon cleansing is often limited by the inability of patients to drink adequate portions of the 4 L solution. The aim of the present study was to determine whether a reduced volume of PEG combined with stimulant laxatives would be better tolerated and as or more effective than the standard dose. METHODS Patients undergoing outpatient colonoscopy were randomly assigned to receive either low-volume PEG plus sennosides (120 mg oral sennosides syrup followed by 2 L PEG) or the standard volume preparation (4 L PEG). The subjects rated the tolerability of the preparations and their symptoms. Colonoscopists were blind to the colonic cleansing preparation and graded the cleansing efficacy using a validated tool (the Ottawa scale). RESULTS The low-volume PEG plus sennosides preparation was significantly better tolerated than the standard large volume PEG (P<0.001) but was less efficacious (P=0.03). Thirty-eight per cent of patients in the large volume PEG group were unable to finish the preparation, compared with only 6% in the reduced volume group. There were no adverse events reported. CONCLUSIONS Although the low-volume PEG plus sennosides preparation was better tolerated, it was not as effective as standard large-volume PEG. However, in view of the significant difference in tolerance, further research investigating possible improvements in the reduced-volume regimen seems warranted. PMID:16482236
Preparation before colonoscopy: a randomized controlled trial comparing different regimes.
Jansen, Sita V; Goedhard, Jelle G; Winkens, Bjorn; van Deursen, Cees Th B M
2011-10-01
A good bowel preparation is essential for optimal visualization of the large intestine. Several preparations with a difference in composition and volume are available. We compared five methods for bowel cleansing quality and patients' acceptability. Adult ambulatory outpatients scheduled for elective colonoscopy were randomized to receive 4-l polyethylene glycol (PEG) solution (Klean-prep), 2-l PEG solution+ascorbic acid (Moviprep), or a sodium phosphate (NaP) solution, Phosphoral. Patients with the PEG solutions were also randomized to receive simethicone (Aeropax), to investigate whether this improves the bowel cleansing efficacy. Before colonoscopy patients completed a questionnaire about the acceptability and tolerability of the preparation. Endoscopists blinded to the type of preparation gave a bowel cleansing score. Data were available for 461 patients. 2-l PEG+ascorbic acid was noninferior to 4-l PEG in bowel cleansing quality of rectosigmoid and colon. NaP was noninferior to 4-l PEG in bowel cleansing quality of rectosigmoid but inferior for the whole colon. Compliance was significantly less in the group with 4-l PEG compared with the 2-l PEG and NaP group. No difference was found for abdominal cramps. Taste was significantly better in the 2-l PEG group. Simethicone did not improve the bowel cleansing quality. 2-l PEG+ascorbic acid was noninferior to the 4-l PEG solution in bowel cleansing quality and was better in taste and compliance. NaP was inferior to 4-l PEG in bowel cleansing quality. Addition of simethicone gave no improvement.
Valiante, Flavio; Bellumat, Angelo; De Bona, Manuela; De Boni, Michele
2013-09-07
To compare the bowel cleansing efficacy, tolerability and acceptability of split 2-L polyethylene glycol (PEG)-citrate-simethicone (PEG-CS) plus bisacodyl (BIS) vs 4-L PEG for fecal occult blood test-positive screening colonoscopy. This was a randomised, observer-blind comparative study. Two hundred and sixty-four subjects underwent screening colonoscopy (mean age 62.5 ± 7.4 years, male 61.7%). The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations. BIS plus PEG-CS: 3 tablets of 5-mg BIS at 16:00, PEG-CS 1-L at 19:00 and 1-L at 7:00, 4-L PEG: 3-L at 17:00, and 1-L at 7:00. Colonoscopy was carried out after 11:00, at least 3 h after the completion of bowel preparation. Bowel cleansing was evaluated using the Harefield Cleansing Scale. Bowel preparation was successful for 92.8% of subjects in the PEG-CS group and for 92.1% of subjects in the 4-L PEG (RR = 1.01; 95%CI: 0.94-1.08). BIS + PEG-CS was better tolerated than 4-L PEG. A greater rate of patients in the BIS + PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group. Subjects in the BIS + PEG-CS group rated the prep as good or satisfactory in 90.6% as compared to 77% in the 4-L PEG (P = 0.003). Subjects receiving BIS + PEG-CS stated they fully adhered to instructions drinking all the 2-L solution in 97.1% compared with 87.3% in the 4-L PEG (P = 0.003). BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split 4-L PEG for screening colonoscopy. This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy.
Kelly, Nicholas Michael; Rodgers, Colin; Patterson, Neil; Jacob, Sudheer George; Mainie, Inder
2012-08-01
High-quality video colonoscopy requires adequate preparation of the bowel to ensure both adequate procedure completion rates and polyp detection rates. We sought to examine our practice to determine which bowel preparation cleansed most effectively in our patients. A prospective audit of the efficacy, safety, and acceptability of low-volume polyethylene glycol (2-L Moviprep; Norgine Pharmaceuticals) versus standard volume polyethylene glycol (4-L KleanPrep; Norgine Pharmaceuticals) versus magnesium citrate (Citramag; Sanochemia UK Ltd.) plus stimulant laxative as bowel preparation for colonoscopy. District General Hospital. Patients attending for day case colonoscopy. Not applicable. Overall cleansing grades of preparations used: patient compliance, taste, and acceptability. A prospective audit of patient experience of taking bowel preparation and blinded colonic scoring assessment of bowel cleansing of each of the tested regimes. A total of 258 (female,138; 53.5%) patients were recruited, 91 in the KleanPrep group (F:45, 49.5%), 86 patients in the Moviprep group (female, 45; 52.3%), and 81 in the Senna/Citramag group (female, 44; 54.3%). Significantly more patients were unable to take the prescribed dose of KleanPrep when compared with the other 2 regimes (19.6%; P<0.0001 vs. Moviprep; P<0.0001 vs. Senna/Citramag). A total of 45.65% of patients reported KleanPrep as tasting unpleasant. This was significantly more than both Moviprep (10.47%; P=0.008) and Senna/Citramag (9.88%; P<0.0001). The overall cleansing efficacy across the 3 groups (those with grades A or B) was 73.9%, 74.5%, and 86.5% for KleanPrep, Moviprep, and Senna/Citramag, respectively. In this series Senna/Citramag proved significantly better at bowel cleansing than KleanPrep (P<0.05) and it showed a trend toward better cleansing when compared with Moviprep (P=0.08). Nonrandomized trial. Split-dosing regime for morning and afternoon lists may have confounded results. In summary, low-volume PEG (Moviprep) and Senna/Citramag combination were better tolerated than large volume PEG with Senna/Citramag providing superior mucosal cleansing.
Evaluation of proposed Skylab and SSP soap products.
NASA Technical Reports Server (NTRS)
Durfee, R. L.; Spurlock, J. M.; Whitmore, F. C.
1973-01-01
Four candidate cleansing agents evaluated in terms of potential hazards to crew members included two soaps (Neutrogena bar soap and Olive Leaf Liquid), one nonfoaming surfactant (Miranol JEM), and one laundry detergent (sodium dodecylbenzene sulfonate). None of the four exhibited adverse dermatological effects from skin patch tests or supported growth of potentially pathogenic microorganisms. Aqueous solutions of Neutrogena did support a mold species. Neutrogena and Miranol JEM were used in a simulated Skylab personal hygiene regimen with no adverse effects on skin or skin microflora. Based on our results, each of these agents appear to be a promising candidate material for the use intended.
Chen, Hong-bin; Huang, Yue; Chen, Su-yu; Song, Hui-wen; Li, Xiao-lin; Dai, Dong-lin; Xie, Jia-tia; He, Song; Zhao, Yuan-yuan; Huang, Chun; Zhang, Sheng-jun; Yang, Lin-na
2011-04-01
There is no consensus concerning small bowel preparation before capsule endoscopy (CE). This study evaluated the effects of 4 regimens on small bowel cleansing and diagnostic yield. Patients were randomly divided into 4 groups. Group A consumed a clear liquid diet after lunch on the day before CE, followed by overnight fasting. Group B took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In group C, the same regimen was taken at 20:00 hours on the day before and at 05:00 hours on the day of CE. In group D, in addition to the group C regimen, 20 mL oral simethicone was taken 30 minutes before CE. Two hundred patients were prospectively enrolled, and 7 were excluded from the final analysis because of incomplete small bowel transit. No significant difference was noted among the 4 groups for small bowel transit time. Bowel preparation in group D was significantly better than for the other regimens for overall cleansing of the proximal small bowel, and showed improved overall cleansing of the distal small bowel when compared with 10-hours overnight fasting. Pathological lesions of the proximal and distal small bowel were, respectively, achieved in 82 and 74 patients, mostly distributed in group D. Small bowel preparation that involves split-dose oral mannitol plus single-dose simethicone for CE can improve mucosal visualization and subsequent diagnostic yield when compared with 10-hours overnight fasting.
Wash water waste pretreatment system
NASA Technical Reports Server (NTRS)
1977-01-01
Investigations were completed on wash waters based on each candidate personal cleansing agent. Evaluations of coagulants, antifoam agents, and the effect of promising antifoams on the chemical precipitation were included. Based on these evaluations two candidate soaps as well as their companion antifoam agents were selected for further work. Operating parameters included the effect of soap concentration, ferric chloride concentration, duration of mixing, and pore size of depth filters on the degree of soap removal. The effect of pressure on water flow through filter cartridges and on the rate of decline of water flow was also investigated. The culmination of the program was the recommendation of a pretreatment concept based on chemical precipitation followed by pressure filtration.
Calixarene cleansing formulation for uranium skin contamination.
Phan, Guillaume; Semili, Naïma; Bouvier-Capely, Céline; Landon, Géraldine; Mekhloufi, Ghozlene; Huang, Nicolas; Rebière, François; Agarande, Michelle; Fattal, Elias
2013-10-01
An oil-in-water cleansing emulsion containing calixarene molecule, an actinide specific chelating agent, was formulated in order to improve the decontamination of uranium from the skin. Commonly commercialized cosmetic ingredients such as surfactants, mineral oil, or viscosifying agents were used in preparing the calixarene emulsion. The formulation was characterized in terms of size and apparent viscosity measurements and then was tested for its ability to limit uranyl ion permeation through excoriated pig-ear skin explants in 24-h penetration studies. Calixarene emulsion effectiveness was compared with two other reference treatments consisting of DTPA and EHBP solutions. Application of calixarene emulsion induced the highest decontamination effect with an 87% decrease in uranium diffusion flux. By contrast, EHBP and DTPA solutions only allowed a 50% and 55% reduction of uranium permeation, respectively, and had the same effect as a simple dilution of the contamination by pure water. Uranium diffusion decrease was attributed to uranyl ion-specific chelation by calixarene within the formulation, since no significant effect was obtained after application of the same emulsion without calixarene. Thus, calixarene cleansing emulsion could be considered as a promising treatment in case of accidental contamination of the skin by highly diffusible uranium compounds.
Stowell, Jennifer D; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L; Dollard, Sheila C; Bialek, Stephanie R; Cannon, Michael J; Schmid, D Scott
2014-01-01
Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 10(5) infectious particles/ml. Samples from hands or surfaces (points between 0 and 15 min) were placed in culture and observed for at least 2 weeks. Samples were also tested using CMV real-time PCR. After application of bacteria to the hands, viable CMV was recovered from 17/20 swabs at 0 min, 18/20 swabs at 1 min, 5/20 swabs at 5 min, and 4/20 swabs at 15 min. After transfer, duration of survival was at least 15 min on plastic (1/2 swabs), 5 min on crackers and glass (3/4 swabs), and 1 min or less on metal and cloth (3/4 swabs); no viable virus was collected from wood, rubber, or hands. After cleansing, no viable virus was recovered using water (0/22), plain soap (0/20), antibacterial soap (0/20), or sanitizer (0/22). Viable CMV was recovered from 4/20 hands 10 min after diaper wipe cleansing. CMV remains viable on hands for sufficient times to allow transmission. CMV may be transferred to surfaces with reduced viability. Hand-cleansing methods were effective at eliminating viable CMV from hands.
Stowell, Jennifer D.; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L.; Dollard, Sheila C.; Bialek, Stephanie R.; Cannon, Michael J.
2014-01-01
Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 105 infectious particles/ml. Samples from hands or surfaces (points between 0 and 15 min) were placed in culture and observed for at least 2 weeks. Samples were also tested using CMV real-time PCR. After application of bacteria to the hands, viable CMV was recovered from 17/20 swabs at 0 min, 18/20 swabs at 1 min, 5/20 swabs at 5 min, and 4/20 swabs at 15 min. After transfer, duration of survival was at least 15 min on plastic (1/2 swabs), 5 min on crackers and glass (3/4 swabs), and 1 min or less on metal and cloth (3/4 swabs); no viable virus was collected from wood, rubber, or hands. After cleansing, no viable virus was recovered using water (0/22), plain soap (0/20), antibacterial soap (0/20), or sanitizer (0/22). Viable CMV was recovered from 4/20 hands 10 min after diaper wipe cleansing. CMV remains viable on hands for sufficient times to allow transmission. CMV may be transferred to surfaces with reduced viability. Hand-cleansing methods were effective at eliminating viable CMV from hands. PMID:24185855
Catheter port cleansing techniques and the entry of povidone-iodine into the epidural space.
Paice, J A; DuPen, A; Schwertz, D
1999-04-01
To determine whether three epidural catheter port cleansing techniques used to apply a povidone-iodine solution differed with respect to the introduction of this solution through the epidural catheter. Experimental. Laboratory. Five DuPen (Davol, Cranston, RI) epidural catheters. Five DuPen epidural catheters each were cleansed twice with (a) a commercially available 10% povidone-iodine swabstick, (b) a commercially available pledget impregnated with 10% povidone-iodine, and (c) a gauze pad saturated with 10% povidone-iodine. The order of cleansing was randomized. Each solution was used to clean the port for 30 seconds, and the port was allowed to dry for 30 seconds, similar to the technique used in the clinical setting. After cleaning the catheter port, water was injected through the catheter, and the solution from the tip of the catheter was analyzed using absorbance spectrophotometry. Cleansing techniques, presence of povidone-iodine in catheter. A statistically significant difference existed between the three cleansing techniques, with the pledget yielding the lowest values of povidone-iodine contamination of the epidural catheter (Freidman test, p = 0.02). Use of pledgets allowed the least amount of povidone-iodine to enter the epidural catheter as compared with the swabsticks or gauze pads. Commercially available pledgets used to cleanse catheter injection ports may limit the introduction of 10% povidone-iodine into the epidural or intrathecal space.
21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.
Code of Federal Regulations, 2010 CFR
2010-04-01
... represented only as soap. (b) Products intended for cleansing the human body and which are not “soap” as set... for use in cleansing the body. 701.20 Section 701.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS COSMETIC LABELING Labeling of Specific...
21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.
Code of Federal Regulations, 2011 CFR
2011-04-01
... represented only as soap. (b) Products intended for cleansing the human body and which are not “soap” as set... use in cleansing the body. 701.20 Section 701.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS COSMETIC LABELING Labeling of Specific...
Spacecraft utensil/hand cleansing fixture
NASA Technical Reports Server (NTRS)
Jonkoniec, T. G.
1978-01-01
A fixture which provides a means for a crewman to perform, in zero gravity, laboratory utensil/tool cleansing and personal hygiene functions such as handwashing, shaving, body wash, and teeth brushing is described. A prototype unit developed incorporating design improvements resulting from breadboard tests in a one gravity and zero gravity environment demonstrated the capability of performing the different cleansing functions.
Zhang, Shenghong; Zheng, Danping; Wang, Jinping; Wu, Jianwei; Lei, Pingguang; Luo, Qi; Wang, Liping; Zhang, Beiping; Wang, Hong; Cui, Yi; Chen, Minhu
2018-04-01
For bowel preparation, using a reduced volume of polyethylene glycol (PEG) solution without influencing its effectiveness would be preferable. While simethicone shows great potential as an adjunctive agent, data on its use are limited. We aimed to clarify whether simethicone added to low-volume PEG solution improved bowel cleansing. PATIENTS AND METHODS : Consecutive adult patients registered for colonoscopy were recruited from seven medical centers in South China between 15 April and 15 July 2015 and prospectively randomized into two groups: 2 L PEG (conventional group) and 2 L PEG plus simethicone (simethicone group). The primary endpoint was the effectiveness of bowel cleansing according to the Boston Bowel Preparation Scale (BBPS). Secondary endpoints included cecal intubation time, adenoma detection rate (ADR), patient safety and compliance, and adverse events. RESULTS : We included 290 and 289 patients in the conventional and simethicone groups, respectively, for analysis. The proportion with acceptable bowel cleansing (BBPS ≥ 6) was significantly higher in the simethicone group than in the conventional group (88.2 % vs. 76.6 %; P < 0.001). The mean (SD) BBPS score was significantly lower in the conventional group (6.5 [1.8] vs. 7.3 [1.7]; P < 0.001), as was the bubble score (2.5 [0.7] vs. 2.8 [0.5]; P < 0.001). The average cecal intubation time was significantly shorter in the simethicone group (6.3 [3.1] vs. 7.5 [5.1] minutes; P < 0.001). The ADR in the right colon was higher in the simethicone group than in the conventional group (16.6 % vs. 10.3 %; P = 0.03). Safety and compliance, including the taste, smell, and dosage of PEG, were similar for both groups. Simethicone added to low-volume PEG solution improves bowel-cleansing efficacy, with similar safety and compliance, shorter cecal intubation time, and higher ADR. © Georg Thieme Verlag KG Stuttgart · New York.
2015-01-01
Objectives Efficacy of two low volume bowel cleansing preparations, polyethylene glycol plus ascorbate (PEG+Asc) and sodium picosulfate/magnesium citrate (NaPic/MgCit), were compared for polyp and adenoma detection rate (PDR and ADR) and overall cleansing ability. Primary endpoint was PDR (the number of patients with ≥1 polypoid or flat lesion recorded by the colonoscopist). Methods Diagnostic, surveillance or screening colonoscopy patients were enrolled into this investigator-blinded, multi-center Phase IV study and randomized 1:1 to receive PEG+Asc (administered the evening before and the morning of colonoscopy, per label) or NaPic/MgCit (administered in the morning and afternoon the day before colonoscopy, per label). The blinded colonoscopist documented any lesion and assessed cleansing quality (Harefield Cleansing Scale). Results Of 394 patients who completed the study, 393 (PEG+Asc, N=200; NaPic/MgCit, N=193) had a colonoscopy. Overall PDR for PEG+Asc versus NaPic/MgCit was 51.5% versus 44.0%, p=0.139. PDR and ADR on the right side of the bowel were significantly higher with PEG+Asc versus NaPic/MgCit (PDR: 56[28.0%] versus 32[16.6%], p=0.007; ADR: 42[21.0%] versus 23[11.9%], p=0.015), as was detection of flat lesions (43[21.5%] versus 25[13.0%], p=0.025). Cleansing quality was better with PEG+Asc than NaPic/MgCit (98.5% versus 57.5% considered successful cleansing). Overall, there were 132 treatment-emergent adverse events (93 versus 39 for PEG+Asc and NaPic/MgCit, respectively). These were mainly mild abdominal symptoms, all of which were reported for higher proportions of patients in the PEG+Asc than NaPic/MgCit group. Twice as many patients in the NaPic/MgCit versus the PEG+Asc group reported tolerance of cleansing solution as ‘very good’. Conclusions Compared with NaPic/MgCit, PEG+Asc may be more efficacious for overall cleansing ability, and subsequent detection of right-sided and flat lesions. This is likely attributable to the different administration schedules of the two bowel cleansing preparations, which may positively impact the detection and prevention of colorectal cancer, thereby improving mortality rates. Trial Registration ClinicalTrials.gov NCT01689792. PMID:25950434
Lavender fragrance cleansing gel effects on relaxation.
Field, Tiffany; Diego, Miguel; Hernandez-Reif, Maria; Cisneros, Wendy; Feijo, Larissa; Vera, Yanexy; Gil, Karla; Grina, Diana; Claire He, Qing
2005-02-01
Alertness, mood, and math computations were assessed in 11 healthy adults who sniffed a cosmetic cleansing gel with lavender floral blend aroma, developed to be relaxing using Mood Mapping. EEG patterns and heart rate were also recorded before, during, and after the aroma session. The lavender fragrance blend had a significant transient effect of improving mood, making people feel more relaxed, and performing the math computation faster. The self-report and physiological data are consistent with relaxation profiles during other sensory stimuli such as massage and music, as reported in the literature. The data suggest that a specific cosmetic fragrance can have a significant role in enhancing relaxation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linguraru, Marius George; Panjwani, Neil; Fletcher, Joel G.
2011-12-15
Purpose: To evaluate the performance of a computer-aided detection (CAD) system for detecting colonic polyps at noncathartic computed tomography colonography (CTC) in conjunction with an automated image-based colon cleansing algorithm. Methods: An automated colon cleansing algorithm was designed to detect and subtract tagged-stool, accounting for heterogeneity and poor tagging, to be used in conjunction with a colon CAD system. The method is locally adaptive and combines intensity, shape, and texture analysis with probabilistic optimization. CTC data from cathartic-free bowel preparation were acquired for testing and training the parameters. Patients underwent various colonic preparations with barium or Gastroview in divided dosesmore » over 48 h before scanning. No laxatives were administered and no dietary modifications were required. Cases were selected from a polyp-enriched cohort and included scans in which at least 90% of the solid stool was visually estimated to be tagged and each colonic segment was distended in either the prone or supine view. The CAD system was run comparatively with and without the stool subtraction algorithm. Results: The dataset comprised 38 CTC scans from prone and/or supine scans of 19 patients containing 44 polyps larger than 10 mm (22 unique polyps, if matched between prone and supine scans). The results are robust on fine details around folds, thin-stool linings on the colonic wall, near polyps and in large fluid/stool pools. The sensitivity of the CAD system is 70.5% per polyp at a rate of 5.75 false positives/scan without using the stool subtraction module. This detection improved significantly (p = 0.009) after automated colon cleansing on cathartic-free data to 86.4% true positive rate at 5.75 false positives/scan. Conclusions: An automated image-based colon cleansing algorithm designed to overcome the challenges of the noncathartic colon significantly improves the sensitivity of colon CAD by approximately 15%.« less
Evaluation of proposed Skylab and SSP soap products
NASA Technical Reports Server (NTRS)
Whitmore, F. C.; Durfee, R. L.; Spurlock, J. M.
1973-01-01
Three personal hygiene cleansing agents and one laundry detergent (sodium dodecyl benzene sulfonate), which are all candidates for use on long-duration space missions, were evaluated in terms of dermatological effects on human subjects and effects on microbiological species. None of the four materials exhibited adverse dermatological effects from either skin patch tests of two weeks duration or a simulated Skylab personal hygiene regimen of up to four weeks duration. No significant alterations in skin microflora during the use regimen were found. None of the four materials were found to serve as microbiological support media for the species tested, but a species of air-borne mold was observed to grow rapidly in a neutralized aqueous solution. None of the candidate agents was found to be strongly biocidal.
NASA Astrophysics Data System (ADS)
Tachibana, Rie; Kohlhase, Naja; Näppi, Janne J.; Hironaka, Toru; Ota, Junko; Ishida, Takayuki; Regge, Daniele; Yoshida, Hiroyuki
2016-03-01
Accurate electronic cleansing (EC) for CT colonography (CTC) enables the visualization of the entire colonic surface without residual materials. In this study, we evaluated the accuracy of a novel multi-material electronic cleansing (MUMA-EC) scheme for non-cathartic ultra-low-dose dual-energy CTC (DE-CTC). The MUMA-EC performs a wateriodine material decomposition of the DE-CTC images and calculates virtual monochromatic images at multiple energies, after which a random forest classifier is used to label the images into the regions of lumen air, soft tissue, fecal tagging, and two types of partial-volume boundaries based on image-based features. After the labeling, materials other than soft tissue are subtracted from the CTC images. For pilot evaluation, 384 volumes of interest (VOIs), which represented sources of subtraction artifacts observed in current EC schemes, were sampled from 32 ultra-low-dose DE-CTC scans. The voxels in the VOIs were labeled manually to serve as a reference standard. The metric for EC accuracy was the mean overlap ratio between the labels of the reference standard and the labels generated by the MUMA-EC, a dualenergy EC (DE-EC), and a single-energy EC (SE-EC) scheme. Statistically significant differences were observed between the performance of the MUMA/DE-EC and the SE-EC methods (p<0.001). Visual assessment confirmed that the MUMA-EC generated less subtraction artifacts than did DE-EC and SE-EC. Our MUMA-EC scheme yielded superior performance over conventional SE-EC scheme in identifying and minimizing subtraction artifacts on noncathartic ultra-low-dose DE-CTC images.
The Search for Legitimacy: Interventions Under the Responsibility to Protect
2012-03-22
the international community bears a responsibility to take action to protect civilians from mass murder, ethnic cleansing , or genocide irrespective...or large scale ‘ethnic cleansing ’ actual or apprehended, whether carried out by killing, forced expulsion, acts of terror or rape.24 The ICISS...temptation to identify as a ground for military intervention human rights violations falling short of outright killing or ethnic cleansing ”26 and did
Unfinished Business: The Sons of Iraq and Political Reconciliation
2010-03-25
out in the National Strategy for Victory in Iraq. 3 of sectarian cleansing in Baghdad, population centric tactics by CF, and increased... cleansed neighborhoods of one sect or the other as the two sides vied for power. Shia families in Sunni dominated areas packed up as many belongings...and Selected Neighborhoods18 8 The Shia controlled government reinforced JAM’s ethnic cleansing operations through a denial of essential
Essentials of Hair Care often Neglected: Hair Cleansing
Draelos, Zoe D
2010-01-01
Why does the selection of hair cleansing products and conditioners seem complex? Why are there clear, opalescent, green, blue, glittery, cheap, expensive, thick, thin, fragrant, and unscented varieties of shampoos and conditioners? Why the whole cleansing process cannot be simplified by using the same bar soap used on the body for the hair? Does the shampoo selected really make a difference? What can a conditioner accomplish? PMID:21188020
Valiante, Flavio; Bellumat, Angelo; De Bona, Manuela; De Boni, Michele
2013-01-01
AIM: To compare the bowel cleansing efficacy, tolerability and acceptability of split 2-L polyethylene glycol (PEG)-citrate-simethicone (PEG-CS) plus bisacodyl (BIS) vs 4-L PEG for fecal occult blood test-positive screening colonoscopy. METHODS: This was a randomised, observer-blind comparative study. Two hundred and sixty-four subjects underwent screening colonoscopy (mean age 62.5 ± 7.4 years, male 61.7%). The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations. Interventions: BIS plus PEG-CS: 3 tablets of 5-mg BIS at 16:00, PEG-CS 1-L at 19:00 and 1-L at 7:00, 4-L PEG: 3-L at 17:00, and 1-L at 7:00. Colonoscopy was carried out after 11:00, at least 3 h after the completion of bowel preparation. Bowel cleansing was evaluated using the Harefield Cleansing Scale. RESULTS: Bowel preparation was successful for 92.8% of subjects in the PEG-CS group and for 92.1% of subjects in the 4-L PEG (RR = 1.01; 95%CI: 0.94-1.08). BIS + PEG-CS was better tolerated than 4-L PEG. A greater rate of patients in the BIS + PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group. Subjects in the BIS + PEG-CS group rated the prep as good or satisfactory in 90.6% as compared to 77% in the 4-L PEG (P = 0.003). Subjects receiving BIS + PEG-CS stated they fully adhered to instructions drinking all the 2-L solution in 97.1% compared with 87.3% in the 4-L PEG (P = 0.003). CONCLUSION: BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split 4-L PEG for screening colonoscopy. This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy. PMID:24023492
Effects of noncontact cleaners on transparent solar materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hampton, H.L.; Lind, M.A.
1979-04-01
A brief study has been undertaken to evaluate the performance of noncontact cleaning agents for use on solar collectors. Several techniques are used to compare cleansing agents which have been recommended by their respective manufacturers for cleaning solar mirrors. Wetting and residue buildup properties are evaluated for over 50 of these commercially available cleaners. The wetting properties of each cleaner are evaluated by measuring the growth of the contact area of a constant volume drop as a function of time. Losses due to residue buildup are solar weighted and considered equally with the wetting parameters and cost figures to constructmore » a figure of merit for cleaner comparison.« less
Low-volume bowel preparation is inferior to standard 4 1 polyethylene glycol.
Haapamäki, Markku M; Lindström, Monica; Sandzén, Birger
2011-03-01
Four liters or more of orally taken polyethylene glycol solution (PEG) has proved to be an effective large-bowel cleansing method prior to colonoscopy. The problem has been the large volume of fluid and its taste, which is unacceptable to some examinees. We aimed to investigate the effectiveness of 2 l PEG combined with senna compared with 4 l PEG for bowel preparation. The design was a single-center, prospective, randomized, investigator-blinded study with parallel assignment, in the setting of the Endoscopy Unit of Umeå University Hospital. Outpatients (n = 490) scheduled for colonoscopy were enrolled. The standard-volume arm received 4 l PEG, and the low-volume arm received 36 mg senna glycosides in tablets and 2 l PEG. The cleansing result (primary endpoint) was assessed by the endoscopist using the Ottawa score. The patients rated the subjective grade of ease of taking the bowel preparation. Analysis was on an intention-to-treat basis. There were significantly more cases with poor or inadequate bowel cleansing after the low-volume alternative with senna and 2 l PEG (22/203) compared with after 4 l PEG (8/196, p = 0.027). The low-volume alternative was better tolerated by the examinees: 119/231 rated the treatment as easy to take compared with 88/238 in the 4 l PEG arm (p = 0.001). 4 l PEG treatment is better than 36 mg senna and 2 l PEG as routine colonic cleansing before colonoscopy because of fewer failures.
NASA Technical Reports Server (NTRS)
1985-01-01
The objective of this research is to define a set of requirements for a whole body cleansing agent to be used in the Space Station Whole Body Shower System. In addition, cleansing agent candidates are to be identified that are likely to satisfy requirements defined in the first part of the study. It is understood that the main reason for having a Whole Body Shower is to satisfy the physiological, psychological and social needs of the crew throughout the duration of duty in the Space Station. The cleansing agent must also be compatible with the vortex water/gas separator and the water reclamation system. To accomplish these goals the study was divided into six tasks.
Yammine, K; Harvey, A
2013-04-01
We report a systematic review and meta-analysis of published randomised and quasi-randomised trials evaluating the efficacy of pre-operative skin antisepsis and cleansing techniques in reducing foot and ankle skin flora. The post-preparation culture number (Post-PCN) was the primary outcome. The data were evaluated using a modified version of the Cochrane Collaboration’s tool. We identified eight trials (560 participants, 716 feet) that met the inclusion criteria. There was a significant difference in the proportions of Post-PCN between hallux nailfold (HNF) and toe web spaces (TWS) sites: 0.47 vs 0.22, respectively (95% confidence interval (CI) 0.182937 to 0.304097; p < 0.0001). Meta-analyses showed that alcoholic chlorhexidine had better efficacy than alcoholic povidone-iodine (PI) at HNF sites (risk difference 0.19 (95% CI 0.08 to 0.30); p = 0.0005); a two-step intervention using PI scrub and paint (S&P) followed by alcohol showed significantly better efficacy over PI (S&P) alone at TWS sites (risk difference 0.13 (95% CI 0.02 to 0.24); p = 0.0169); and a two-step intervention using chlorhexidine scrub followed by alcohol showed significantly better efficacy over PI (S&P) alone at the combined (HNF with TWS) sites (risk difference 0.27 (95% CI 0.13 to 0.40); p < 0.0001). No significant difference was found between cleansing techniques.
Nur-E-Alam, M; Islam, M Monirul; Islam, M Nazrul; Rima, Farhana Rahman; Islam, M Nurul
2016-03-01
The cleansing efficiencies of laundry detergents depend on composition and variation of ingredients such as surfactants, phosphate, and co-builders. Among these ingredients, surfactants and phosphate are considered as hazardous materials. Knowledge on compositions and micellar behavior is very useful for understanding their cleansing efficiencies and environmental impact. With this view, composition, critical micelle concentration, and dissolved oxygen level in aqueous solution of some laundry detergents available in Bangladesh such as keya, Wheel Power White, Tibet, Surf Excel, and Chaka were determined. Surfactant and phosphate were found to be maximum in Surf Excel and Wheel Power White, respectively, while both of the ingredients were found to be minimum in Tibet. The critical micelle concentration decreased with increasing surfactant content. The amount of laundry detergents required for efficient cleansing was found to be minimum for Surf Excel and maximum for Chaka; however, cleansing cost was the highest for Surf Excel and the lowest for Tibet. The maximum amount of surfactants and phosphate was discharged by Surf Excel and Wheel Power White, respectively, while discharges of both of the ingredients were minimum for Tibet. The maximum decrease of dissolved oxygen level was caused by Surf Excel and the minimum by Tibet. Therefore, it can be concluded that Tibet is cost-effective and environment friendly, whereas Surf Excel and Wheel Power White are expensive and pose a threat to water environment.
[Persistent reddening and induration after wound cleansing with octenidine].
Seegräber, M; T Ruzicka; Wollenberg, A
2017-04-01
With its long-lasting effectiveness, octenidine is an agent of first choice for antiseptic wound treatment. However, the manufacturer advises against instillation of the agent under pressure. A 50-year-old patient presented with erythema and extensive soft tissue induration after wound cleansing with octenidine under pressure. Due to the lack of resorption of the agent, this caused long-lasting interstitial soft tissue edema. This case demonstrates the importance of following the manufacturer's instructions for use. Advantages of the agent such as lack of systemic toxicity or broad spectrum efficacy can only be achieved if the agent is applied correctly.
Systems and methods for data quality control and cleansing
Wenzel, Michael; Boettcher, Andrew; Drees, Kirk; Kummer, James
2016-05-31
A method for detecting and cleansing suspect building automation system data is shown and described. The method includes using processing electronics to automatically determine which of a plurality of error detectors and which of a plurality of data cleansers to use with building automation system data. The method further includes using processing electronics to automatically detect errors in the data and cleanse the data using a subset of the error detectors and a subset of the cleansers.
... cortisone or prednisone, high-dose intravenous immunoglobulin, or irradiation. Plasmapheresis, a process that cleanses antibodies from the ... cortisone or prednisone, high-dose intravenous immunoglobulin, or irradiation. Plasmapheresis, a process that cleanses antibodies from the ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall, L.C.; Daniels, J.I.; Aly, R.
Historically, military personnel deployed in the field, particularly in hot, humid environments, have suffered disabling microbial infections of the skin severe enough to contribute to significant reductions in combat-troop strength. Currently, the US Army makes facilities available to field personnel for showering on a weekly basis to prevent infestations of the body louse and the subsequent spread of louse-borne disease. However, a weekly showering frequency has never been evaluated for its efficacy in preventing microbial infections of the skin -- a significant cause of man-days lost from combat in modern-day military conflicts. Consequently, field showers may be more important formore » maintaining combat effectiveness of military personnel than previously thought; however, providing such facilities requires tremendous logistical support. Therefore, we developed shower frequencies for troops in field environments that should minimize or prevent microbial skin infections. According to our calculations, the optimum showering frequency can range from as often as four times per day to as little as once every seven days, depending on skin integrity, environmental conditions, and cleansing agent. We also reviewed the scientific and regulatory information concerning the efficacy and safety of skin-cleansing products; the antimicrobial and antiseptic compounds, triclocarban and chlorhexidine, may be the most suitable for routine use by US military personnel.« less
Niv, Galia; Grinberg, Tamar; Dickman, Ram; Wasserberg, Nir; Niv, Yaron
2013-01-01
Constipation is a common complaint, frequently treated with cleansing enema. Enemas can be very effective but may cause serious adverse events, such as perforation or metabolic derangement. Our aim was to evaluate the outcome of the use of cleansing enema for acute constipation and to assess adverse events within 30 days of therapy. We performed a two-phase study: an initial retrospective and descriptive study in 2010, followed by a prospective study after intervention, in 2011. According to the results of the first phase we established guidelines for the treatment of constipation in the Emergency Department and then used these in the second phase. There were 269 and 286 cases of severe constipation in the first and second periods of the study, respectively. In the first study period, only Fleet® Enema was used, and in the second, this was changed to Easy Go enema (free of sodium phosphate). There was a 19.2% decrease in the total use of enema, in the second period of the study (P < 0.0001). Adverse events and especially, the perforation rate and the 30-day mortality in patients with constipation decreased significantly in the second phase: 3 (1.4%) versus 0 (P = 0.0001) and 8 (3.9%) versus 2 (0.7%) (P = 0.0001), for perforation and death in the first and second period of the study, respectively. Enema for the treatment of acute constipation is not without adverse events, especially in the elderly, and should be applied carefully. Perforation, hyperphosphatemia (after Fleet Enema), and sepsis may cause death in up to 4% of cases. Guidelines for the treatment of acute constipation and for enema administration are urgently needed.
Niv, Galia; Grinberg, Tamar; Dickman, Ram; Wasserberg, Nir; Niv, Yaron
2013-01-01
Objectives Constipation is a common complaint, frequently treated with cleansing enema. Enemas can be very effective but may cause serious adverse events, such as perforation or metabolic derangement. Our aim was to evaluate the outcome of the use of cleansing enema for acute constipation and to assess adverse events within 30 days of therapy. Methods We performed a two-phase study: an initial retrospective and descriptive study in 2010, followed by a prospective study after intervention, in 2011. According to the results of the first phase we established guidelines for the treatment of constipation in the Emergency Department and then used these in the second phase. Results There were 269 and 286 cases of severe constipation in the first and second periods of the study, respectively. In the first study period, only Fleet® Enema was used, and in the second, this was changed to Easy Go enema (free of sodium phosphate). There was a 19.2% decrease in the total use of enema, in the second period of the study (P < 0.0001). Adverse events and especially, the perforation rate and the 30-day mortality in patients with constipation decreased significantly in the second phase: 3 (1.4%) versus 0 (P = 0.0001) and 8 (3.9%) versus 2 (0.7%) (P = 0.0001), for perforation and death in the first and second period of the study, respectively. Conclusion Enema for the treatment of acute constipation is not without adverse events, especially in the elderly, and should be applied carefully. Perforation, hyperphosphatemia (after Fleet Enema), and sepsis may cause death in up to 4% of cases. Guidelines for the treatment of acute constipation and for enema administration are urgently needed. PMID:23658492
Chen, Hong-Bin; Lian-Xiang, Peng; Yue, Huang; Chun, Huang; Shu-Ping, Xiao; Rong-Pang, Lin; Xiao-Zong, Wang; Xiao-Lin, Li
2017-10-01
The approach to small bowel preparation before capsule endoscopy (CE) is still suboptimal. One hundred eighty patients were randomly allocated to 3 groups. Patients in Group A took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In Group B the same preparation was taken at 20:00 on the day before, and at 05:00 on the day of CE; in addition, 20 mL oral simethicone was taken 30 minutes before CE. Group C was treated identically to Group B, except that the patients fasted for 3 days and took 3 g senna orally 3 times daily before CE. The length of bowel containing green luminal contents was assessed by ImageJ software and bowel cleanliness was evaluated by computed assessment of the cleansing score. Cleansing of the whole small bowel and the distal small bowel were significantly different between the 3 groups (χ = 22.470, P = .000; χ = 17.029, P = .000, respectively). There were also significant differences between the 3 groups in the length of small bowel and specifically the length of the distal small bowel containing green luminal contents (χ = 12.390, P = .000, χ = 15.141, P = .000, respectively), but not with regard to the proximal small bowel (χ = 0.678, P = .509). Three days fasting and oral senna, combined with 20% mannitol and simethicone, before CE, can reduce the effects of bile on the small bowel and improve small bowel cleansing, especially in the distal small intestine.
Munsterman, Isabelle D; Eskes, Anne M; Maaskant, Jolanda M; van der Hulst, René
2016-01-01
Background An effective and tolerable bowel preparation is important to secure quality of colonoscopies. It remains unclear if sodium picosulphate with magnesium citrate (SPMC), which is considered a tolerable bowel preparation agent, is also an effective alternative for polyethylene glycol (PEG) and sodium phosphate (NaP). Aim The aim of this article is to compare effectiveness of SPMC to PEG and NaP through assessment of quality of bowel cleansing measured by validated tools. Methods We searched electronic databases up to January 2015. Only randomised controlled trials (RCTs) were included. Two authors independently performed selection of studies, risk of bias assessment and data extraction. Results Thirteen RCTs were included, with overall good quality, but large heterogeneity. SPMC had slightly better quality of bowel cleansing than PEG (pooled RR 1.06; 95% CI 1.02 to 1.11). In most trials SPMC was significantly better tolerated than PEG. There were no significant differences in effectiveness or tolerability between SPMC and NaP. Side effects were similar between agents, except for dizziness (pooled RR 1.71; 95% CI 1.32 to 2.21 in favour of PEG vs. SPMC) and vomiting (pooled RR 0.35; 95% CI 0.13 to 0.95 in favour of single-dose SPMC vs. split-dose). Conclusions SPMC is equally effective to NaP and little superior to PEG in terms of bowel cleansing. SPMC preparations were better tolerated than PEG preparations. SPMC may be considered as standard bowel preparation for colonoscopy. PMID:29163958
Whole-bowel irrigation for mechanical colon cleansing.
Michael, K A; DiPiro, J T; Bowden, T A; Tedesco, F J
1985-01-01
The physiology, solution composition, indications, efficacy, and safety of whole-bowel irrigation (WBI) for mechanical bowel cleansing are reviewed. WBI with isotonic electrolyte solutions produces diarrhea when the infusion rate exceeds the capacity of the intestine to distend and absorb the solution. A number of solutions are used for WBI, including 0.9% sodium chloride, balanced electrolyte solutions, lactated Ringer's, mannitol, and electrolyte solutions containing polyethylene glycol 3350 (PEG). WBI solution administration rates vary from 15-90 mL/min, by oral ingestion or nasogastric tube, with total volumes ranging from 1 to 20 L. The onset of diarrhea occurs as soon as 20 minutes with clearing of the effluent as early as 90 minutes. Faster administration rates appear to shorten overall cleansing time. Two PEG-electrolyte lavage solutions (ELSs) have recently gained FDA approval. The recommended dosage rate is 1.2-1.8 L/hr orally or by nasogastric tube until rectal effluent is clear. In most patients, this requires a maximum of 4-6 L. Initial data indicate that PEG-ELSs are safe for elderly patients and for patients who have an increased risk of fluid overload, but these solutions have not been evaluated in children, pregnant women, or patients with inflammatory bowel disease. WBI is an effective alternative to other regimens for removing fecal material and reducing bowel lumen bacterial counts before colonoscopy and colorectal surgery. Retention of bacterial counts before colonoscopy and colorectal surgery. Retention of excess WBI solution may interfere with the quality of barium enema radiographs; this can be minimized by completing the irrigation the evening before the examination. Gastrointestinal side effects occur in about one third of the patients following WBI, but do not generally require discontinuing the irrigation. Solutions containing PEG with sodium sulfate as the primary electrolyte result in the least net water and electrolyte movement and are preferred over other solutions.
Kelling, C K; Bartolo, R G; Ertel, K D; Smith, L A; Watson, D D; Sarlo, K
1998-02-01
Enzyme-containing personal cleansing products were being considered for the consumer market. Although enzymes have been marketed safely for many years as ingredients in laundry products, their use in a personal cleansing application represented a new type of exposure for consumers that was not supported by the historical safety data. An exposure assessment and additional safety data would be needed before marketing to ensure consumer safety. The work in this paper was designed to evaluate the potential for inhalation exposure to the enzyme during use of this new product while showering. Then a clinical trial was conducted to determine whether or not the level, duration, and routes of exposure encountered during use of this product would induce a Type I sensitization response to the enzyme. Exposure was assessed during normal showering activities by collecting air samples with both high volume and personal samplers and quantitating enzyme levels with an ELISA. To assess the potential for sensitization, panelists were asked to use a prototype protease-containing bar product for all personal cleansing tasks and to keep a use diary reporting any associated symptoms. Physical and dermatologic examinations and skin prick tests with enzyme were conducted before the test commenced and at 2-month intervals. Exposure assessment results showed that airborne enzyme levels were primarily dependent on the concentration of the enzyme in the personal cleansing product. Mean values for total airborne enzyme protein ranged from 5.7 to 11.8 ng/m3 when enzyme concentration, time of use, and measurement technique remained constant. After 6 months of at-home product use, four of 61 test subjects using the enzyme-containing bar had positive skin prick test responses when tested with the enzyme. The skin prick test data were supplemented with serologic analyses, which detected IgE specific for the protease enzyme. None of these subjects showed any clinical symptoms indicative of allergic reaction. The ability of enzymes to induce development of allergic antibodies in this study led to the conclusion that this prototype enzyme-containing personal cleansing bar would represent an inappropriate use of enzymes in a consumer product application. The likelihood of both induction of an immunologic response and subsequent elicitation of allergy symptoms in a small but significant fraction of the user population was high. This finding resulted in the decision to halt further development of this prototype.
Ojha, Saroj Kumar; Javdekar, Sadashiv Bhaskar; Dhir, Sangeeta
2015-01-01
Context: Plaque control has been shown to be pivotal in maintaining the optimal periodontal health. Mechanical plaque control is the most popular option for establishing the optimal oral health. Toothbrushes have been the novel tool for mechanical cleansing. However, the abrasive potential of the toothbrushes on the enamel surface is an area in gray. Aims: The aim of this in vitro study is to evaluate the abrasivity of the toothbrush versus the velcro fasteners. Materials and Methods: The mounted teeth of both the groups were subjected to abrasion test, and the tooth surfaces were observed for the possible abrasions from the oscillating strokes (toothbrush) and frictional contacts (hook and loop velcro) and examined under the scanning electron microscope. Results: Comparative assessment of both velcro (hook and loop) and toothbrush bristles did not reveal any evidence of abrasion on the tooth specimens. Conclusions: Veclro fasteners are safe and qualitatively at par to the manual toothbrush for their efficacy and efficiency in teeth cleansing PMID:26229264
You, Wenguang; Masri, Radi; Romberg, Elaine; Driscoll, Carl F; You, Tao
2011-08-01
The effect of denture cleansing solutions and multiple pulls on the retention of pink Locator patrices was studied. Five groups of pink Locator attachments (3.0 lb. Light Retention replacement patrix attachments; five in each group) were soaked for the equivalent of 6 months of clinical use in the following solutions: water (control), Efferdent, Polident Overnight, 6.15% sodium hypochlorite (NaOCL, 1:10 dilution), and Listerine mouthwash. A universal testing machine set at a 2 in/min crosshead speed was used to perform 548 pulls (548 cycles of insertion and removal). The reduction in load to dislodgement (retention) after the initial pull and the final pull and the percent reduction in retention after 6 months were compared between the groups using a one-way ANOVA followed by Tukey's Honestly Significant Difference (HSD) Test (α= 0.05). Denture cleansing solutions significantly reduced the retentive values of pink Locator attachments after the initial pull (F = 17.435, p < 0.0001). The retentive values of Efferdent, Listerine, Polident Overnight, and water were significantly higher than the retentive value of the attachments soaked in NaOCl. After 6 months of simulated use (548 pulls), the four denture cleansing solutions had significant effects on the retentive values of pink Locator attachments (F = 5.855, p = 0.003). The retentive values for attachments soaked in NaOCl (7.29 ± 1.0 N) were significantly lower than those of attachments soaked in Listerine (15.82 ± 4.7 N) and in Polident Overnight (14.41 ± 3.6 N). These cleansing solutions also had a significant effect on the percentage of retention lost (F = 3.271, p = 0.032). The loss of retention in attachments soaked in Listerine (29 ± 9%) was significantly lower than attachments soaked in water (53 ± 12%). The loss of retention in attachments soaked in Efferdent was 49 ± 9%; in Polident Overnight, 34 ± 18%; and in NaOCl, 42 ± 11%. There was no significant difference in the percentage of retention loss between water, Efferdent, NaOCl, and Polident Overnight. There was also no significant difference in the percentage of retention loss between Efferdent, NaOCl, Polident Overnight, and Listerine. NaOCl significantly decreased the retentive value of Locators. Therefore, it should not be routinely recommended for use as a denture cleanser. Listerine significantly increased the retention of the Locator attachments; however, it is premature to recommend Listerine for use as a denture cleanser. © 2011 by The American College of Prosthodontists.
A critical evaluation and a search for the ideal colonoscopic preparation.
Arora, Manish; Senadhi, Viplove; Arora, Deepika; Weinstock, Joyce; Dubin, Ethan; Okolo, Patrick I; Dutta, Sudhir K
2013-04-01
The aim of this study was to evaluate the efficacy of various bowel preparations in accomplishing colonic cleansing for optimal mucosal visualization during colonoscopy. The study included a cohort of 980 patients who underwent colonoscopy at our endoscopy center within the last 3 years. All of the study patients were subdivided into four groups. Each group included 245 patients, all receiving a different type of bowel preparation. The bowel preparations used in this study included: magnesium citrate (Group I), a combination of oral sodium phosphate (fleets) and powder PEG-3350 (Group II), powder polyethylene glycol-3350 (PEG-3350 powder for Group III), and oral sodium phosphate (fleets for Group IV). A Colon Prep Score (CPS) was devised to compare the quality of the different bowel preparations used. The colonoscopy results from all of these patients were tabulated and analyzed statistically and expressed as mean ± 1 standard deviation. Statistical analysis was performed using a one way ANOVA with Holm-Sidak method for intergroup analysis. Group I patients received magnesium citrate and had a mean CPS ± 1 SD of 3.11 ± 0.91. Group II patients (fleets and powder PEG-3350 combination) achieved a CPS of 3.37 ± 1.16. The patients in Group III (powder PEG-3350) actually showed the highest mean CPS of 3.44 ± 1.12. Group IV patients who used oral sodium phosphate alone reached a mean CPS of 3.23 ± 1.01. Group III patients (powder PEG-3350 only) demonstrated a statistically higher CPS (P<0.0006) in colon cleansing as compared to Group I patients (magnesium citrate). Similarly, Group II patients (oral sodium phosphate and powder PEG-3350 combination) also showed improved colon cleansing statistically (P<0.006) as compared to Group I patients (magnesium citrate). Overall, all four colon preparations achieved an average CPS greater than 3.0 indicating clinically adequate colonic cleansing. However, powder PEG-3350 alone and in combination with oral sodium phosphate was observed to be statistically superior to magnesium citrate, when used for colon preparation for colonoscopy. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Sagawa, Toshihiko; Tomizawa, Taku; Mizuide, Masafumi; Yasuoka, Hidetoshi; Shimoyama, Yasuyuki; Kakizaki, Satoru; Kawamura, Osamu; Kusano, Motoyasu; Yamada, Masanobu
2015-01-01
Polyethylene glycol- (PEG-) based bowel preparations for colonoscopies are often poorly tolerated due to the large volumes of fluid intake required. We compared low-volume “modified” PEG + ascorbic acid (AJG522) with standard PEG with electrolytes (PEG + E) in addition to a stimulant laxative and an agent to improve bowel function for the bowel cleansing before colonoscopy to evaluate its efficacy, safety, and acceptability. Outpatients scheduled to undergo colonoscopy were randomized to receive either AJG522 or PEG + E. Bowel cleansing conditions were assessed via macroscopic fecal findings by blinded and independent investigators. A survey of the patients' feedback regarding the preparation was conducted by questionnaire. Successful cleansing was achieved in all cases, except for 4 cases in the PEG + E group, at 3 hours after taking the preparation. The fecal properties were significantly clearer in the AJG522 group than in the PEG + E group at 2 hours after taking each preparation (P = 0.013). Although the total liquid volume of the bowel preparation was not reduced, the AJG522 preparation could significantly reduce the required volume of the preparation (P < 0.0001). Moreover, the patients in the AJG522 group had better acceptability (P = 0.010). There were no significant differences in the safety profiles between groups (UMIN000013892). PMID:25688357
Caged ATP - an internal calibration method for ATP bioluminescence assays.
Calvert, R M; Hopkins, H C; Reilly, M J; Forsythe, S J
2000-03-01
ATP bioluminescence, based on the firefly luciferase system, is used for the rapid determination of hygienic practices in the food industry. This study has demonstrated the use of caged ATP as an internal ATP standard and quantified the effects of industrial cleansing solutions, alcoholic beverages and pH on firefly luciferase activity. The light signal was quenched 6-47% by five cleansing solutions at standard working concentrations. Ethanol at 1% (v/v) inhibited bioluminescence by 15% (w/v) whereas concentrations above 4% enhanced the light output. The light signal was quenched by 20-25% at pH values below pH 4 and above pH 10.
Baby Shampoo Versus Povidone-Iodine or Isopropyl Alcohol in Reducing Eyelid Skin Bacterial Load.
Garcia, Giancarlo A; Nguyen, Christine V; Yonkers, Marc A; Tao, Jeremiah P
Baby shampoo is used as an alternative surgical skin preparation, but the evidence supporting its use is scarce with no descriptions of efficacy in the periocular region. The authors compare the efficacy of baby shampoo, povidone-iodine (PI, Betadine) and isopropyl alcohol (IA) in reducing eyelid skin bacterial load. Prospective, randomized, comparative, and interventional trial. Bacterial load on adult, human eyelid skin was quantitated before and after cleansing with 1) dilute baby shampoo, 2) 10% PI, or 3) 70% IA. Paired skin swabs were collected from a 1 cm area of the upper eyelid of subjects before and after a standardized surgical scrub technique. Samples were cultured on 5% sheep blood agar for 24 hours. The number of colony forming units (CFU) was assessed and bacterial load per square centimeter of eyelid skin was quantified. Baseline and postcleansing samples were assessed from 42 eyelids of 42 subjects (n = 14 for each of baby shampoo, PI, and IA). Before cleansing, similar amounts of bacterial flora were grown from all specimens (median log CFU/cm = 2.04 before baby shampoo, 2.01 before PI, 2.11 before IA; p > 0.05). All 3 cleansing agents significantly reduced the bacterial load (p < 0.01 for each). There was no statistically significant difference in postcleansing bacterial load between the 3 cleansing agents (median log CFU/cm = 0.48 after baby shampoo, 0.39 after PI, 0.59 after IA; p > 0.05). Change from baseline in bacterial load was statistically similar for all 3 agents (median reduction in log CFU/cm = 1.28 with baby shampoo, 1.57 with PI, 1.40 with IA; p > 0.05). These corresponded to bacterial load reductions of 96.3%, 96.6%, and 98.4% for baby shampoo, PI, and IA, respectively. Baby shampoo achieved comparable diminution in eyelid skin bacterial load to PI or IA. These data suggest baby shampoo may be an effective preoperative cleansing agent.
Panchabhai, Tanmay S; Dangayach, Neha S; Krishnan, Anand; Kothari, Vatsal M; Karnad, Dilip R
2009-05-01
Oral cleansing with chlorhexidine decreases the incidence of nosocomial pneumonia in patients after cardiac surgery. However, evidence of its benefit in ICU patients is conflicting. Patients admitted to the ICU of an Indian tertiary care teaching hospital were randomized to twice-daily oropharyngeal cleansing with 0.2% chlorhexidine or 0.01% potassium permanganate (control) solution. Effects on the incidence of nosocomial pneumonia during ICU stay (primary outcome) and length of ICU stay and in-hospital mortality (secondary outcomes) were studied. Five hundred twelve patients were randomized to either the chlorhexidine group (n = 250) or the control group (n = 262). Of the 471 subjects who completed the protocol, nosocomial pneumonia developed in 16 of 224 subjects (7.1%) in the chlorhexidine group and 19 of 247 subjects (7.7%) in the control group (p = 0.82; relative risk, 0.93; 95% confidence interval, 0.49 to 1.76); intention-to-treat analysis of 21 patients in whom the cleansing protocol was not followed revealed similar results. There was no significant difference between the study and control groups in the median day of development of pneumonia (5.0 days: interquartile range [IQR], 3.0 to 7.7 vs 5.0 days: IQR, 3.0 to 6.0, respectively), median ICU stay (5.0 days: IQR, 3.0 to 8.0 vs 6.0 days: IQR, 3.0 to 8.0, respectively), and mortality (34.8% vs 28.3%, respectively). On subgroup analysis, there was no significant difference in the primary and secondary outcomes in patients on mechanical ventilation, tracheal intubation, and coma (Glasgow coma scale
Development and efficacy assessments of tea seed oil makeup remover.
Parnsamut, N; Kanlayavattanakul, M; Lourith, N
2017-05-01
The efficacy of tea seed oil to clean foundation and eyeliner was evaluated. The safe and efficient tea seed oil makeup remover was developed. In vitro cleansing efficacy of makeup remover was UV-spectrophotometric validated. The stability evaluation by means of accelerated stability test was conducted. In vitro and in vivo cleansing efficacy of the removers was conducted in a comparison with benchmark majorly containing olive oil. Tea seed oil cleaned 90.64±4.56% of foundation and 87.62±8.35% of eyeliner. The stable with most appropriate textures base was incorporated with tea seed oil. Three tea seed oil removers (50, 55 and 60%) were stabled. The 60% tea seed oil remover significantly removed foundation better than others (94.48±3.37%; P<0.001) and the benchmark (92.32±1.33%), but insignificant removed eyeliner (87.50±5.15%; P=0.059). Tea seed oil remover caused none of skin irritation as examined in 20 human volunteers. A single-blind, randomized control exhibited that the tea seed oil remover gained a better preference over the benchmark (75.42±8.10 and 70.00±7.78%; P=0.974). The safe and efficient tea seed oil makeup removers had been developed. The consumers' choices towards the makeup remover containing the bio-oils are widen. In vitro cleansing efficacy during the course of makeup remover development using UV-spectrophotometric method feasible for pharmaceutic industries is encouraged. Copyright © 2016 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.
Shieh, Frederick K.; Gunaratnam, Naresh; Mohamud, Sagal O.; Schoenfeld, Philip
2012-01-01
Background Polyethylene Glycol-3350 without electrolytes (MiraLAX®; Schering-Plough Healthcare Products Inc.) + a carbohydrate-electrolyte solution (Gatorade; PepsiCo Inc.) + bisacodyl is frequently used for bowel cleansing, although limited data quantifies its efficacy and safety. No prior studies have assessed this in a community setting or with PM-only dosing, which is still used frequently. Aim To compare the frequency of excellent/good/fair/poor bowel cleansing with PM-only dosing of MiraLAX®-Gatorade-bisacodyl vs. 4L GoLytely®. Methods This is a retrospective endoscopic database analysis of ≥ 50 year old average-risk individuals with a normal screening colonoscopy at a community hospital and ambulatory endoscopy center. Data was extracted for the last four months when 4L GoLytely® was the preferred bowel purgative and the first 4 months when 238g MiraLAX® in 64 ounces Gatorade and four 5-mg bisacodyl tablets became the preferred purgative. All patients used PM-only dosing of bowel purgative. Results 778 subjects [GoLytely® (n=395) vs. MiraLAX® + Gatorade + bisacodyl (n=383)] were identified. Patients who took the MiraLAX® bowel preparation were more likely to achieve an excellent/good bowel cleansing compared to patients taking the GoLytely® preparation (93.3% vs. 89.3%, respectively; p = 0.048). However, when only ASA Class I patients are studied, there was no difference in frequency of excellent/good bowel cleansing (91.1% vs 93.6%, respectively; p = 0.498). No serious adverse events were identified. An excellent/good bowel cleansing was strongly associated with a recommendation for repeat colonoscopy in 10 years compared to patients with a fair cleansing [OR = 28.01; 95% CI: 13.96-56.19]. Conclusions The MiraLAX® + Gatorade + bisacodyl combination produces similar rates of excellent/good bowel cleansing as compared to GoLytely® in most average-risk individuals undergoing colonoscopy for CRC screening in a community setting. PMID:23060223
Turner, D; Levine, A; Weiss, B; Hirsh, A; Shamir, R; Shaoul, R; Berkowitz, D; Bujanover, Y; Cohen, S; Eshach-Adiv, O; Jamal, Gera; Kori, M; Lerner, A; On, A; Rachman, L; Rosenbach, Y; Shamaly, H; Shteyer, E; Silbermintz, A; Yerushalmi, B
2010-12-01
There are no current recommendations for bowel cleansing before colonoscopy in children. The Israeli Society of Pediatric Gastroenterology and Nutrition (ISPGAN) established an iterative working group to formulate evidence-based guidelines for bowel cleansing in children prior to colonoscopy. Data were collected by systematic review of the literature and via a national-based survey of all endoscopy units in Israel. Based on the strength of evidence, the Committee reached consensus on six recommended protocols in children. Guidelines were finalized after an open audit of ISPGAN members. Data on 900 colonoscopies per year were accrued, which represents all annual pediatric colonoscopies performed in Israel. Based on the literature review, the national survey, and the open audit, several age-stratified pediatric cleansing protocols were proposed: two PEG-ELS protocols (polyethylene-glycol with electrolyte solution); Picolax-based protocol (sodium picosulphate with magnesium citrate); sodium phosphate protocol (only in children over the age of 12 years who are at low risk for renal damage); stimulant laxative-based protocol (e. g. bisacodyl); and a PEG 3350-based protocol. A population-based analysis estimated that the acute toxicity rate of oral sodium phosphate is at most 3/7320 colonoscopies (0.041 %). Recommendations on diet and enema use are provided in relation to each proposed protocol. There is no ideal bowel cleansing regimen and, thus, various protocols are in use. We propose several evidence-based protocols to optimize bowel cleansing in children prior to colonoscopy and minimize adverse events. © Georg Thieme Verlag KG Stuttgart · New York.
Mohammed, Hilal S.; Singh, Sumeet; Hari, Prasad A.; Amarnath, G. S.; Kundapur, Vinaya; Pasha, Naveed; Anand, M.
2016-01-01
Background and objective: Chemical cleansing by denture cleansers is first choice for denture plaque control. The most common problems while using denture cleansers are hardening, porosity, odor sorption, water sorption, solubility, and colour change, bacterial and fungal growth. Chemical cleansing procedures have been found to have an effect on the physical and mechanical properties of denture liners. Thus, this study was conducted to evaluate the effect of commercially available denture cleansers on surface hardness and roughness of acrylic and silicon based denture liners at various time interval. Method: Two autopolymerising denture liners Kooliner (acrylic) and GC reline soft (silicon) were tested with two commercially available denture cleansers, polident and efferdent plus. Total of 120 specimens were prepared and all the specimens were divided into six groups based on the relining materials and denture cleansers used. Surface hardness and surface roughness was tested using Shore A durometer and profilometer respectively at the end of day 1, day 7, day 30 and day 90. All the specimens were stored in artificial saliva throughout the study. Cleanser solution was prepared daily by adding Polident and Efferdent plus denture cleanser tablet into 250ml of enough very warm (not hot) water. Acrylic and silicon liner groups were cleansed in a solution of denture cleanser and water for 15 minutes daily, rinsed with water and stored in artificial saliva at room temperature. The data was analyzed with one way ANOVA and independent t-test. Result: The acrylic soft lining showed gradual hardening and increase in surface roughness after immersion in denture cleanser and also with time. Acrylic liner material showed maximum hardness and roughness with Polident followed by Efferdent plus and water (control group). Silicone lining material showed a slight difference in hardness and roughness between the test group and control group. There was a slight increase in hardness in all the groups with time. Very slight increase in mean surface roughness of all the silicon liner groups from day 1 to day 90 was observed. A statistically significant change was noted between and within the all silicon liner groups on day 7, day 30 and day 90. Conclusion: The average surface hardness and surface roughness were lower in silicon liner material than acrylic liner material. Maximum surface roughness was noted by Polident followed by Efferdent Plus and Water for both acrylic liner group and silicon liner group. PMID:28190983
Evaluation of a new ostomy mouldable seal: an international product evaluation.
Tielemans, Chantal; Probert, Rosalind; Forest-Lalande, Louise; Hansen, Anne Steen; Aggerholm, Søren; Ajslev, Teresa Adeltoft
2016-12-08
A new mouldable seal, Brava® Protective Seal, was evaluated by patients on aspects related to residue, durability, and preference. A total of 135 patients from four countries participated (Denmark, Germany, Japan and the USA) and the new product was compared to the patients' usual pouching systems. Less residue and easier skin cleansing was observed, which may benefit patient quality of life. The possible benefits of less residue for peristomal skin health need further investigation.
Treatment of Biofouling in Internal Seawater Systems - Phase 2
2007-11-01
Denture Cleansing Tablets. Issue Date: Feb 2006. Reckitt Benckiser 12 In the first instance, in July 2006, mussels were transferred directly to an...Denture Cleansing Tablets (Reckit Benckiser , West Ryde) Chemical composition11: Potassium peroxymonosulfate 10-30% Sodium carbonate % Citric
WhoKnows? Evaluating Linked Data Heuristics with a Quiz that Cleans up DBpedia
ERIC Educational Resources Information Center
Waitelonis, Jorg; Ludwig, Nadine; Knuth, Magnus; Sack, Harald
2011-01-01
Purpose: Linking Open Data (LOD) provides a vast amount of well structured semantic information, but many inconsistencies may occur, especially if the data are generated with the help of automated methods. Data cleansing approaches enable detection of inconsistencies and overhauling of affected data sets, but they are difficult to apply…
Zorzi, Manuel; Valiante, Flavio; Germanà, Bastianello; Baldassarre, Gianluca; Coria, Bartolomea; Rinaldi, Michela; Heras Salvat, Helena; Carta, Alessandra; Bortoluzzi, Francesco; Cervellin, Erica; Polo, Maria Luisa; Bulighin, Gianmarco; Azzurro, Maurizio; Di Piramo, Daniele; Turrin, Anna; Monica, Fabio
2016-03-01
The high volume and poor palatability of 4 L of polyethylene glycol (PEG)-based bowel cleansing preparation required before a colonoscopy represent a major obstacle for patients. The aim of this study was to compare two low volume PEG-based preparations with standard 4 L PEG in individuals with a positive fecal immunochemical test (FIT) within organized screening programs in Italy. A total of 3660 patients with a positive FIT result were randomized to receive, in a split-dose regimen, 4 L PEG or 2 L PEG plus ascorbate (PEG-A) or 2 L PEG with citrate and simethicone plus bisacodyl (PEG-CS). The noninferiority of the low volume preparations vs. 4 L PEG was tested through the difference in proportions of adequate cleansing. A total of 2802 patients were included in the study. Adequate bowel cleansing was achieved in 868 of 926 cases (93.7 %) in the 4 L PEG group, in 872 out of 911 cases in the PEG-A group (95.7 %, difference in proportions + 1.9 %, 95 % confidence interval [CI] - 0.1 to 3.9), and in 862 out of 921 cases in the PEG-CS group (93.6 %, difference in proportions - 0.2 %, 95 %CI - 2.4 to 2.0). Bowel cleansing was adequate in 95.5 % of cases when the preparation-to-colonoscopy interval was between 120 and 239 minutes, whereas it dropped to 83.3 % with longer intervals. Better cleansing was observed in patients with regular bowel movements (95.6 %) compared with those with diarrhea (92.4 %) or constipation (90.8 %). Low volume PEG-based preparations administered in a split-dose regimen guarantee noninferior bowel cleansing compared with 4 L PEG. Constipated patients require a personalized preparation. EudraCT 2012 - 003958 - 82. © Georg Thieme Verlag KG Stuttgart · New York.
Francis, Suzanna C.; Baisley, Kathy; Lees, Shelley S.; Andrew, Bahati; Zalwango, Flavia; Seeley, Janet; Vandepitte, Judith; Ao, Trong T.; van de Wijgert, Janneke; Watson-Jones, Deborah; Kapiga, Saidi; Grosskurth, Heiner; Hayes, Richard J.
2013-01-01
Background Intravaginal practices (IVP) are highly prevalent in sub-Saharan African and have been implicated as risk factors for HIV acquisition. However, types of IVP vary between populations, and detailed information on IVP among women at risk for HIV in different populations is needed. We investigated IVP among women who practice transactional sex in two populations: semi-urban, facility workers in Tanzania who engage in opportunistic sex work; and urban, self-identified sex workers and bar workers in Uganda. The aim of the study was to describe and compare IVP using a daily pictorial diary. Methodology/Principal Findings Two hundred women were recruited from a HIV prevention intervention feasibility study in Kampala, Uganda and in North-West Tanzania. Women were given diaries to record IVP daily for six weeks. Baseline data showed that Ugandan participants had more lifetime partners and transactional sex than Tanzanian participants. Results from the diary showed that 96% of Tanzanian participants and 100% of Ugandan participants reported intravaginal cleansing during the six week study period. The most common types of cleansing were with water only or water and soap. In both countries, intravaginal insertion (e.g. with herbs) was less common than cleansing, but insertion was practiced by more participants in Uganda (46%) than in Tanzania (10%). In Uganda, participants also reported more frequent sex, and more insertion related to sex. In both populations, cleansing was more often reported on days with reported sex and during menstruation, and in Uganda, when participants experienced vaginal discomfort. Participants were more likely to cleanse after sex if they reported no condom use. Conclusions While intravaginal cleansing was commonly practiced in both cohorts, there was higher frequency of cleansing and insertion in Uganda. Differences in IVP were likely to reflect differences in sexual behaviour between populations, and may warrant different approaches to interventions targeting IVP. Vaginal practices among women at high risk in Uganda and Tanzania: recorded behaviour from a daily pictorial diary. PMID:23555618
Aziz, M A; Imteaz, M A; Huda, Nazmul; Naser, J
2014-01-01
After heavy rainfall, sewer overflow spills to receiving water bodies cause serious concern for the environment, aesthetics and public health. To overcome these problems this study investigated a new self-cleansing sewer overflow screening device. The device has a sewer overflow chamber, a rectangular tank and a slotted ogee weir to capture the gross pollutants. To design an efficient screening device a numerical computational fluid dynamic (CFD) model was used. A plausibility check of the CFD model was done using a one-dimensional analytical model. Results showed that an inlet parallel to the weir ensured better self-cleansing than an inlet perpendicular to the weir. Perforations should be at the bottom of the weir to get increased velocity and shear stress to create a favourable self-cleaning effect of the screening device. Increasing inlet length from 0.3 to 1.5 m reduced wave reflection up to 10%, which increased flow uniformity downstream and improved self-cleansing effect. The orientation of the ogee weir with the rectangular tank was found most uniform with a 1:3 (horizontal:vertical) slope. These results will help to maximise functional efficiency of the new sewer overflow screening device. Otherwise it would be too expensive to alter after installation and at times difficult to customise accordingly to existing urban drainage systems.
Chen, Hong-bin; Lian-xiang, Peng; Yue, Huang; Chun, Huang; Shu-ping, Xiao; Rong-pang, Lin; Xiao-zong, Wang; Xiao-lin, Li
2017-01-01
Abstract Background and Study Aims: The approach to small bowel preparation before capsule endoscopy (CE) is still suboptimal. Patients and Methods: One hundred eighty patients were randomly allocated to 3 groups. Patients in Group A took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In Group B the same preparation was taken at 20:00 on the day before, and at 05:00 on the day of CE; in addition, 20 mL oral simethicone was taken 30 minutes before CE. Group C was treated identically to Group B, except that the patients fasted for 3 days and took 3 g senna orally 3 times daily before CE. The length of bowel containing green luminal contents was assessed by ImageJ software and bowel cleanliness was evaluated by computed assessment of the cleansing score. Results: Cleansing of the whole small bowel and the distal small bowel were significantly different between the 3 groups (χ2 = 22.470, P = .000; χ2 = 17.029, P = .000, respectively). There were also significant differences between the 3 groups in the length of small bowel and specifically the length of the distal small bowel containing green luminal contents (χ2 = 12.390, P = .000, χ2 = 15.141, P = .000, respectively), but not with regard to the proximal small bowel (χ2 = 0.678, P = .509). Conclusions: Three days fasting and oral senna, combined with 20% mannitol and simethicone, before CE, can reduce the effects of bile on the small bowel and improve small bowel cleansing, especially in the distal small intestine. PMID:29069003
Yeo, Se Hwan; Kwak, Jae Hoon; Kim, Yeo Un; Kwon, Tae Ho; Park, Jeong Bae; Park, Jun Hyung; Lee, Yong Kook; Lim, Yun Jeong; Yang, Chang Heon
2016-04-25
There are no studies that looked into the bubble eliminating efficacy of polyethylene glycol with ascorbic acid (PEGA), which has been one of the shortcomings of polyethylene glycol (PEG). In this study, we compared newly introduced PEGA regimen by adding either simethicone or 1 L of water. A prospective randomized controlled study was carried out at Dongguk Universtiy Gyeongju Hospital from July 2014 to September 2014. A total of 90 patients were randomly assigned to 3 groups; PEGA group (n=30) which served as control, simethicone addition group (n=30) to which simethicone 400 mg was additionally prescribed, and water addition group (n=30) to whom additional 1 L of water was given. Cleansing effectiveness, gas elimination efficacy, side effects, and patient satisfaction were compared between the groups. PEGA group demonstrated the highest cleansing effectiveness, but there was no statistically significant difference among the groups. Simethicone addition group showed significantly lesser amount of bubbles than the other groups (2.57±2.05 vs. 1.10±1.83 vs. 2.60±2.84, p=0.017). The rates of side effects in each group were 20.00% vs. 16.77% vs. 53.33%. Water addition group had significantly more side effects than the PEGA group and the simethicone addition group (p=0.003). The patient satisfaction score of each group was 3.37±0.85 vs. 3.73±0.74 vs. 3.20±0.66 with simethicone addition group showing significantly higher satisfaction than water addition group (p=0.020). PEGA bowel preparation agent showed satisfactory bowel cleansing despite the decrease in dosage, and addition of simethicone resulted in better bubble elimination.
Haldavnekar, Richa Vivek; Tekur, Padmini; Nagarathna, Raghuram; Nagendra, Hongasandra Ramarao
2014-01-01
Background: Studies have shown that Integrated Yoga reduces pain, disability, anxiety and depression and increases spinal flexibility and quality-of-life in chronic low back pain (CLBP) patients. Objective: The objective of this study was to compare the effect of two yoga practices namely laghu shankha prakshalana (LSP) kriya, a yogic colon cleansing technique and back pain specific asanas (Back pain special technique [BST]) on pain, disability, spinal flexibility and state anxiety in patients with CLBP. Materials and Methods: In this randomized control (self as control) study, 40 in-patients (25 were males, 15 were females) between 25 and 70 years (44.05 ± 13.27) with CLBP were randomly assigned to receive LSP or BST sessions. The measurements were taken immediately before and after each session of either of the practices (30 min) in the same participant. Randomization was used to decide the day of the session (3rd or 5th day after admission) to ensure random distribution of the hang over effect of the two practices. Statistical analysis was performed using the repeated measures analysis of variance. Results: Significant group * time interaction (P < 0.001) was observed in 11 point numerical rating scale, spinal flexibility (on Leighton type Goniometer) and (straight leg raise test in both legs), Oswestry Disability Index, State Anxiety (XI component of Spieldberger's state and trait anxiety inventory. There was significantly (P < 0.001, between groups) better reduction in LSP than BST group on all variables. No adverse effects were reported by any participant. Conclusion: Clearing the bowel by yoga based colon cleansing technique (LSP) is safe and offers immediate analgesic effect with reduced disability, anxiety and improved spinal flexibility in patients with CLBP. PMID:25035620
DiPalma, J A; Marshall, J B
1990-01-01
A new sulfate-free polyethylene glycol electrolyte lavage solution (SF-ELS) for colonoscopy was formulated to taste better and have less net water and electrolyte secretion and absorption than a standard polyethylene glycolelectrolyte lavage solution (PEG-ELS). At two centers, 157 patients were prospectively randomized to receive SF-ELS or PEG-ELS to assess adequacy of preparation, patient tolerance, weight changes, and various hematologic and biochemical parameters. Physician assessment of colon cleansing showed no difference between those patients receiving SF-ELS (N = 74) or PEG-ELS (N = 78). Eighty-two percent of all preps were found to be "clinically acceptable." Subjects receiving SF-ELS had significantly less fullness and cramps, while PEG-ELS subjects reported less nausea. There was no difference between groups for vomiting, overall discomfort, or willingness to repeat the preparation received. Eighty percent of all patients would repeat the randomized cleansing methods. There were no clinically significant changes in weight or assessed laboratory parameters, with the exception of potassium where PEG-ELS patients had an mean decrease of 0.22 mEq/liter vs. 0.01 mEq/liter for SF-ELS (p less than or equal to 0.01). Patient taste questionnaires in those patients expressing a preference showed a preference for SF-ELS (76.6%) over PEG-ELS (23.4%) (p less than or equal to 0.001). Thirty-two (22.5%) of total respondents indicated no preference. We conclude that SF-ELS when compared with PEG-ELS is similarly a safe and effective method of colon cleansing for colonoscopy that is well tolerated. Patients prefer the taste of the new solution.
Davies, R H; Wray, C
1996-01-01
Three broiler breeder houses on three different sites were sampled before and after cleansing and disinfection. None of the farms achieved total elimination of Salmonella enteritidis from the poultry house environment but substantial improvements were seen when errors in the cleansing and disinfection protocol in the first house had been corrected. Fundamental errors such as over-dilution and inconsistent application of disinfectants were observed despite supervision of the process by technical advisors. In each of the three poultry units failure to eliminate a mouse population that was infected with S. enteritidis was likely to be the most important hazard for the next flock.
Faot, Fernanda; Cavalcanti, Yuri Wanderley; Mendonça e Bertolini, Martinna de; Pinto, Luciana de Rezende; da Silva, Wander José; Cury, Altair Antoninha Del Bel
2014-06-23
It is well known that the use of denture cleansers can reduce Candida albicans biofilm accumulation; however, the efficacy of citric acid denture cleansers is uncertain. In addition, the long-term efficacy of this denture cleanser is not well established, and their effect on residual biofilms is unknown. This in vitro study evaluated the efficacy of citric acid denture cleanser treatment on C. albicans biofilm recolonization on poly(methyl methacrylate) (PMMA) surface. C. albicans biofilms were developed for 72 h on PMMA resin specimens (n = 168), which were randomly assigned to 1 of 3 cleansing treatments (CTs) overnight (8 h). CTs included purified water as a control (CTC) and two experimental groups that used either a 1:5 dilution of citric acid denture cleanser (CT5) or a 1:8 dilution of citric acid denture cleanser (CT8). Residual biofilms adhering to the specimens were collected and quantified at two time points: immediately after CTs (ICT) and after cleaning and residual biofilm recolonization (RT). Residual biofilms were analyzed by quantifying the viable cells (CFU/mL), and biofilm architecture was evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Denture cleanser treatments and evaluation periods were considered study factors. Data were analyzed using two-way ANOVA and Tukey's Honestly Significant Difference (HSD) test (α = 0.05). Immediately after treatments, citric acid denture cleansing solutions (CT5 and CT8) reduced the number of viable cells as compared with the control (p < 0.01). However, after 48 h, both CT groups (CT5 and CT8) showed biofilm recolonization (p < 0.01). Residual biofilm recolonization was also detected by CLSM and SEM analysis, which revealed a higher biomass and average biofilm thickness for the CT8 group (p < 0.01). Citric acid denture cleansers can reduce C. albicans biofilm accumulation and cell viability. However, this CT did not prevent biofilm recolonization.
Hartmann, Miriam; Montgomery, Elizabeth T.; Colvin, Christopher J.; Mensch, Barbara; van der Straten, Ariane
2015-01-01
We investigated condom and lubricant use, rectal cleansing and rectal gel use for penile-anal intercourse (PAI), during in-depth interviews with women from South Africa, Uganda and Zimbabwe who formerly participated in VOICE, a five-arm HIV prevention trial of two antiretroviral tablets and a vaginal gel. Few studies have addressed practices related to PAI among women; existing data from Africa on condom and lubricant use for PAI, as well as preparatory practices of PAI such as rectal cleansing, are limited to men who have sex with men. Women demonstrated a lack of awareness of HIV transmission risks of PAI and none of the participants reported using condom-compatible lubricants for PAI. Participants described a variety of preparatory rectal cleansing practices. Some participants disclosed rectal use of the vaginal study gel. Understanding practices related to PAI in Africa is critical to microbicide development, as these practices are likely to influence the acceptability, feasibility, and use of both vaginal and rectal microbicide products. PMID:26126586
NASA Technical Reports Server (NTRS)
Mohanty, Susmita
2001-01-01
This document was originally published in 1997 as a International Space University Master of Space Studies student's project. While the specifics may be a little dated, the results gleaned are still relevant and valid. Johnson Space Center is now abuzz with preparations for the International Space Station. The work on the various systems for the U.S. Habitation Module will begin in 1998. As a prelude, the Flight Crew Support Division perceived the need to take a closer, more critical took at planning the Whole Body Cleansing function for ISS. This report is an endeavour to retrieve all data available on whole body cleansing mechanisms used, past and present, by the Russians and the Americans, analyze it and create design concepts for products/product systems for zero-g whole body cleansing on ISS Alpha, for typical duration of about 90 days. This report takes a close look at the Skylab collapsible shower, the Mir shower/sauna, the full body cleansing methods currently in use onboard the Space Shuttle and Mir and at the Whole Body Shower designed and tested for Space Station Freedom. It attempts to "listen" carefully to what the Mir astronauts (Norm Thagard, Shannon Lucid and John Blaha) have to say about their personal hygiene experiences during their recent stays on Mir. The findings in the report call for a change in paradigm. What is good for Earth conditions is not necessarily good for Zero-g! It concludes that a shower is not a good idea for the ISS. The final concept that is proposed reflects very strongly what the Mir astronauts would like to have and to use onboard a station like the ISS, The report concludes with directions of how to take the "idea" further and realize it in the form of a product system for Whole Body Cleansing onboard the ISS.
Improving of bowel cleansing effect for polyethylene glycol with ascorbic acid using simethicone
Yoo, In Kyung; Jeen, Yoon Tae; Kang, Seung Hun; Lee, Jae Hyung; Kim, Seung Han; Lee, Jae Min; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Chun, Hoon Jai; Lee, Hong Sik; Kim, Chang Duck
2016-01-01
Abstract Background and Aim: Low-volume polyethylene glycol with ascorbic acid (PEG-Asc) use is reported to be as safe and effective as traditional 4-L polyethylene glycol use. However, PEG-Asc produces bubbles, which cause problems during colonoscopy. Data on the effects of using antifoaming agents such as simethicone with PEG-Asc are lacking. The aim of this CONSORT-prospective, randomized, observer-blinded, controlled trial is to compare the quality of bowel preparation and compliance between PEG-Asc users and PEG-Asc plus simethicone users. Methods: Adult outpatients aged 18 to 80 years undergoing colonoscopy were recruited to the study. Two hundred sixty patients were randomly assigned to 1 of 2 treatment arms, PEG-Asc or PEG-Asc plus simethicone. The primary outcome measure was the bowel cleansing quality using Boston bowel preparation scale and bubble scores. The secondary outcome measures were patient tolerability and doctor tolerability. Results: The simethicone group showed superior cleansing results (6–9 Boston scale scores: 99% vs. 84%, <5% bubble scores: 96% vs. 49%, P < 0.001) and fewer gastrointestinal symptoms (abdominal fullness: 24% vs. 55%, colicky pain: 5% vs. 24%, P < 0.001) than the non-simethicone group. Moreover, endoscopist fatigue during colonoscopy was lower in the simethicone group than in the non-simethicone group (1.31 ± 0.75 vs. 2.97 ± 2.14, P < 0.001). Conclusion: PEG-Asc plus simethicone use was more effective and associated with better patient and endoscopist tolerance than PEG-Asc use. Therefore, this combination is recommended as one of the promising methods for bowel preparation before colonoscopy. PMID:27428209
Yoo, In Kyung; Jeen, Yoon Tae; Kang, Seung Hun; Lee, Jae Hyung; Kim, Seung Han; Lee, Jae Min; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Chun, Hoon Jai; Lee, Hong Sik; Kim, Chang Duck
2016-07-01
Low-volume polyethylene glycol with ascorbic acid (PEG-Asc) use is reported to be as safe and effective as traditional 4-L polyethylene glycol use. However, PEG-Asc produces bubbles, which cause problems during colonoscopy. Data on the effects of using antifoaming agents such as simethicone with PEG-Asc are lacking. The aim of this CONSORT-prospective, randomized, observer-blinded, controlled trial is to compare the quality of bowel preparation and compliance between PEG-Asc users and PEG-Asc plus simethicone users. Adult outpatients aged 18 to 80 years undergoing colonoscopy were recruited to the study. Two hundred sixty patients were randomly assigned to 1 of 2 treatment arms, PEG-Asc or PEG-Asc plus simethicone. The primary outcome measure was the bowel cleansing quality using Boston bowel preparation scale and bubble scores. The secondary outcome measures were patient tolerability and doctor tolerability. The simethicone group showed superior cleansing results (6-9 Boston scale scores: 99% vs. 84%, <5% bubble scores: 96% vs. 49%, P < 0.001) and fewer gastrointestinal symptoms (abdominal fullness: 24% vs. 55%, colicky pain: 5% vs. 24%, P < 0.001) than the non-simethicone group. Moreover, endoscopist fatigue during colonoscopy was lower in the simethicone group than in the non-simethicone group (1.31 ± 0.75 vs. 2.97 ± 2.14, P < 0.001). PEG-Asc plus simethicone use was more effective and associated with better patient and endoscopist tolerance than PEG-Asc use. Therefore, this combination is recommended as one of the promising methods for bowel preparation before colonoscopy.
A 6% Benzoyl Peroxide Foaming Cloth Cleanser Used in the Treatment of Acne Vulgaris
2009-01-01
Objective: The study was conducted to evaluate the product attributes of a new benzoyl peroxide-containing foaming cloth cleanser and to compare the overall patient satisfaction of this product with two currently available benzoyl peroxide acne products (6% benzoyl peroxide cleanser and 4% benzoyl peroxide wash). Design: This was a randomized, single-blind study. Setting: Two clinical trial sites. Participants: Male and female subjects (N=193) aged 17 to 30 years with a history of acne vulgaris were enrolled. Measures: Subjects initially cleansed their face with the benzoyl peroxide foaming cloth and then completed a product-attribute survey. Following an interval of five minutes or more, subjects cleansed their face again using one of two randomly assigned comparator benzoyl peroxide-containing cleansing products and then completed a comparative survey. Survey results were tabulated and a top-two box analysis was performed. Results: Following the use of the benzoyl peroxide-containing foaming cloth, 94 percent of the product-attribute responses were positive (p≤0.05). With respect to convenience, usability, and cosmetic elegance, the majority of subjects indicated a preference for the benzoyl peroxide foaming cloth compared to the 6% benzoyl peroxide cleanser and 4% benzoyl peroxide wash (for each, p≤0.05). There were no reports of adverse events. Conclusion: These attributes supporting preference for the benzoyl peroxide foaming cloth cleanser may improve patient satisfaction with topical acne treatment resulting in improved patient compliance. (J Clin Aesthetic Dermatol. 2009;2(7):26–29.) PMID:20729967
van de Wijgert, Janneke H H M; Morrison, Charles S; Cornelisse, Peter G A; Munjoma, Marshall; Moncada, Jeanne; Awio, Peter; Wang, Jing; Van der Pol, Barbara; Chipato, Tsungai; Salata, Robert A; Padian, Nancy S
2008-06-01
To evaluate interrelationships between bacterial vaginosis (BV), vaginal yeast, vaginal practices (cleansing and drying/tightening), mucosal inflammation, and HIV acquisition. A multicenter, prospective, observational cohort study was conducted, enrolling 4531 HIV-negative women aged 18 to 35 years attending family planning clinics in Zimbabwe and Uganda. Participants were tested for HIV and reproductive tract infections and were interviewed about vaginal practices every 3 months for 15 to 24 months. BV was measured by Gram stain Nugent scoring, vaginal yeast by wet mount, and mucosal inflammation by white blood cells on Gram stain. HIV incidence was 4.12 and 1.53 per 100 woman-years of follow-up in Zimbabwe and Uganda, respectively (a total of 213 incident infections). Women with BV or vaginal yeast were more likely to acquire HIV, especially if the condition was present at the same visit as the new HIV infection and the visit preceding it (hazard ratio [HR] = 2.50, 95% confidence interval [CI]: 1.68 to 3.72 and HR = 2.97, 95% CI: 1.67 to 5.28 for BV and yeast, respectively). These relationships did not seem to be mediated by mucosal inflammation. Vaginal drying/tightening was associated with HIV acquisition in univariate (HR = 1.49, 95% CI: 1.03 to 2.15) but not multivariate models. Vaginal cleansing was not associated with HIV acquisition. BV and yeast may contribute more to the HIV epidemic than previously thought.
Kuehle, Christiane A; Langhorst, Jost; Ladd, Susanne C; Zoepf, Thomas; Nuefer, Michael; Grabellus, Florian; Barkhausen, Joerg; Gerken, Guido; Lauenstein, Thomas C
2007-01-01
Background and aim To evaluate the diagnostic accuracy of magnetic resonance colonography (MRC) without bowel cleansing in a screening population and compare the results to colonoscopy as a standard of reference. Methods 315 screening patients, older than 50 years with a normal risk profile for colorectal cancer, were included in this study. For MRC, a tagging agent (5.0% Gastrografin, 1.0% barium sulphate, 0.2% locust bean gum) was ingested with each main meal within 2 days prior to MRC. No bowel cleansing was applied. For the magnetic resonance examination, a rectal water enema was administered. Data collection was based on contrast enhanced T1 weighted images and TrueFISP images. Magnetic resonance data were analysed for image quality and the presence of colorectal lesions. Conventional colonoscopy and histopathological samples served as reference. Results In 4% of all colonic segments, magnetic resonance image quality was insufficient because of untagged faecal material. Adenomatous polyps >5 mm were detected by means of MRC, with a sensitivity of 83.0%. Overall specificity was 90.2% (false positive findings in 19 patients). However, only 16 of 153 lesions <5 mm and 9 of 127 hyperplastic polyps could be visualised on magnetic resonance images. Conclusions Faecal tagging MRC is applicable for screening purposes. It provides good accuracy for the detection of relevant (ie, adenomatous) colorectal lesions >5 mm in a screening population. However, refinements to optimise image quality of faecal tagging are needed. PMID:17341542
Asaoka, Kentaro; Endo, Shiro; Suzuki, Yuki; Komuro, Satoru; Nemoto, Tadanobu; Kaku, Mitsuo
2016-08-01
Staphylococcus aureus is known to form a biofilm and colonize on damaged skin of the hands. We investigated changes in the quantity of S aureus on the hands and changes in skin damage when using a hand-cleansing formulation with potassium oleate but without a sanitizer (formulation A), which is highly effective in removing S aureus biofilm and causes minimal skin damage. The participants (14 medical staff members) used 2 types of hand-cleansing formulations (formulations A and B), each for 4 weeks. S aureus of the hands was cultured from swab samples on agar plates. Surface of hands was measured using an ultraviolet light microscope. The quantity of S aureus after using formulation A for 4 weeks was 10(1.08 ± 0.05) CFU/mL, a statistically significant decrease from the quantity of S aureus (10(1.59 ± 0.19) CFU/mL) just before use (P = .029). Also, dryness of hand surfaces decreased. With formulation B, the quantity of S aureus did not significantly change from before to after use (P > .05). This presumably occurs because formulation A gently removes S aureus biofilm. Formulation A removed S aureus from the hands of participants, and skin damage on the hands improved. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Design of a unit to produce hot distilled water for the same power consumption as a water heater
NASA Technical Reports Server (NTRS)
Bambenek, R. A.; Nuccio, P. P.
1973-01-01
Unit recovers 97% of water contained in pretreated waste water. Some factors are: cleansing agent prevents fouling of heat transfer surface by highly concentrated waste; absence of dynamic seals reduces required purge gas flow rate; and recycle loop maintains constant flushing process to carry cleansing agent across evaporation surface.
Transportation Secure Data Center | NREL
Data Center The Transportation Secure Data Center (TSDC) provides free access to detailed transportation data from a variety of travel surveys and studies. Data include global positioning system (GPS demographics. Learn more about the TSDC. Cleansed Data by State and Region Use the map to access cleansed data
Matro, Rebecca; Tupchong, Keegan; Daskalakis, Constantine; Gordon, Victoria; Katz, Leo; Kastenberg, David
2012-11-29
Colonic bubbles associated with polyethylene glycol-electrolyte solution (PEG-ELS) are common and obscure mucosal visualization. This study aimed to determine whether adding simethicone decreases the incidence of bubbles. Prospective, single-blind, randomized comparison of split dose PEG-ELS vs. PEG-ELS+simethicone (PEG-S) for outpatient colonoscopy. Bubble severity for colonic segments was assessed on withdrawal as A=no/minimal bubbles, B=moderate bubbles/interfere with detecting 5 mm polyp, C=severe bubbles/interfere with detecting 10 mm polyp. Primary end point was Grade B or C bubbles in any colon segment. Secondary end points were cleansing quality, incidence and severity of side effects, and polyp detection. One hundred and thirty nine patients enrolled; 13 withdrew before colonoscopy. Of 123 patients evaluated, 62 took PEG-S and 61 PEG-ELS. The incidence of grade B or C bubbles was much lower with PEG-S compared with PEG-ELS (2% vs. 38%; P=0.001). Overall cleansing (excellent or good) quality was not significantly different for either the whole colon (89% PEG-ELS, 94% of PEG-S, P=0.529) or right colon (88% PEG-ELS, 94% PEG-S, P=0.365). More PEG-S patients had excellent rather than good preps (whole colon 53% vs. 28%, P=0.004; right colon 53% vs. 35%, P=0.044). Need for any flushing was less with PEG-S (38% vs. 70%, P=0.001). The groups were not significantly different with respect to total procedure and withdrawal times, incidence or severity of side effects, or number of polyps/patient or adenomas/patient. Adding simethicone to PEG-ELS effectively eliminates bubbles, substantially reduces the need for flushing, and results in more excellent preparations.
Matro, Rebecca; Tupchong, Keegan; Daskalakis, Constantine; Gordon, Victoria; Katz, Leo; Kastenberg, David
2012-01-01
OBJECTIVES: Colonic bubbles associated with polyethylene glycol-electrolyte solution (PEG-ELS) are common and obscure mucosal visualization. This study aimed to determine whether adding simethicone decreases the incidence of bubbles. METHODS: Prospective, single-blind, randomized comparison of split dose PEG-ELS vs. PEG-ELS+simethicone (PEG-S) for outpatient colonoscopy. Bubble severity for colonic segments was assessed on withdrawal as A=no/minimal bubbles, B=moderate bubbles/interfere with detecting 5 mm polyp, C=severe bubbles/interfere with detecting 10 mm polyp. Primary end point was Grade B or C bubbles in any colon segment. Secondary end points were cleansing quality, incidence and severity of side effects, and polyp detection. RESULTS: One hundred and thirty nine patients enrolled; 13 withdrew before colonoscopy. Of 123 patients evaluated, 62 took PEG-S and 61 PEG-ELS. The incidence of grade B or C bubbles was much lower with PEG-S compared with PEG-ELS (2% vs. 38% P=0.001). Overall cleansing (excellent or good) quality was not significantly different for either the whole colon (89% PEG-ELS, 94% of PEG-S, P=0.529) or right colon (88% PEG-ELS, 94% PEG-S, P=0.365). More PEG-S patients had excellent rather than good preps (whole colon 53% vs. 28%, P=0.004; right colon 53% vs. 35%, P=0.044). Need for any flushing was less with PEG-S (38% vs. 70%, P=0.001). The groups were not significantly different with respect to total procedure and withdrawal times, incidence or severity of side effects, or number of polyps/patient or adenomas/patient. CONCLUSIONS: Adding simethicone to PEG-ELS effectively eliminates bubbles, substantially reduces the need for flushing, and results in more excellent preparations. PMID:23238113
Washing away your (good or bad) luck: physical cleansing affects risk-taking behavior.
Xu, Alison Jing; Zwick, Rami; Schwarz, Norbert
2012-02-01
Many superstitious practices entail the belief that good or bad luck can be "washed away." Consistent with this belief, participants who recalled (Experiment 1) or experienced (Experiment 2) an episode of bad luck were more willing to take risk after having as opposed to not having washed their hands, whereas participants who recalled or experienced an episode of good luck were less willing to take risk after having as opposed to not having washed their hands. Thus, the psychological effects of physical cleansings extend beyond the domain of moral judgment and are independent of people's motivation: incidental washing not only removes undesirable traces of the past (such as bad luck) but also desirable ones (such as good luck), which people would rather preserve.
Rex, Douglas K; Katz, Philip O; Bertiger, Gerald; Vanner, Stephen; Hookey, Lawrence C; Alderfer, Vivian; Joseph, Raymond E
2013-07-01
New bowel cleansers for colonoscopy that lead to improved efficacy, safety, and tolerability are needed. This study evaluated a nonphosphate, dual-action, low-volume, orange-flavored preparation containing sodium picosulfate and magnesium citrate (P/MC). Multicenter, assessor-blinded, randomized, noninferiority study. University hospitals, academic medical centers, and private clinics across the United States. Adults preparing for colonoscopy. P/MC versus 2 L of polyethylene glycol solution (2L PEG-3350) and two 5-mg bisacodyl tablets. This phase 3 study investigated the efficacy, safety, and tolerability of split-dose administration of P/MC versus day-before dosing of 2L PEG-3350 and two 5-mg bisacodyl tablets (SEE CLEAR I study). Efficacy was evaluated by using the Aronchick and Ottawa scales; noninferiority and superiority analyses were performed. Safety was assessed by monitoring adverse events (AEs). Tolerability was measured via a patient questionnaire. The intent-to-treat population consisted of 601 patients who self-administered P/MC (n = 304) or 2L PEG-3350 and bisacodyl tablets (n = 297). P/MC was superior to 2L PEG-3350 and bisacodyl tablets in overall colon cleansing (84.2% vs 74.4%; 1-sided 97.5% confidence interval [CI], 3.4) (Aronchick scores of excellent or good) and in cleansing of the ascending (89.5% vs 78.8%; 1-sided 97.5% CI, 4.9), mid (transverse and descending) (92.4% vs 85.9%; 1-sided 97.5% CI, 1.6), and rectosigmoid (92.4% vs 87.2%; 1-sided 97.5% CI, 0.4) segments of the colon (Ottawa scores of excellent, good, or fair). Commonly reported AEs related to the bowel preparations were nausea, vomiting, headache, and chills. Patient-reported tolerability, including ease of consumption and taste, was significantly higher for P/MC than 2L PEG-3350 and bisacodyl tablets (P < .0001). Because of differences in administration and volume of the bowel preparations, the study was designed to be a single-assessor, blinded study. The bowel-cleansing effects and patient acceptability of split-dose P/MC were superior to day-before dosing with 2L PEG-3350 and bisacodyl tablets. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Colyte and Colyte-flavored (PEG-3350 & electrolytes) for oral solution for gastrointestinal lavage.
Pickering, P
1994-06-01
Colyte and Colyte-flavored are effective in preparing the bowel for endoscopic examination, particularly when used in combination with saline and stimulant laxatives, which may decrease the volume of Colyte required for optimal bowel cleansing.
Gentile, Maurizio; De Rosa, Michele; Cestaro, Giovanni; Forestieri, Pietro
2013-06-01
The 2 L polyethylene glycol (PEG) lavage solution has been proved to be similarly safe and effective as 4 L PEG formulations, in spite of the reduced volume. To compare low-volume PEG-based solution combined with ascorbic acid with high-volume PEG-based solution combined with simethicon in terms of efficacy and patient tolerability. This was a single-blind prospective randomized trial. Patients were randomized to receive either 2 L PEG plus ascorbic acid (PEG+Asc) or 4 L PEG plus simethicon (PEG+Sim). The primary endpoint was overall colon cleansing evaluation, assessed by blinded investigators using Aronchick score. Secondary end points included patient compliance and tolerability and adverse events. Sixty patients received PEG+Asc and 60 received PEG+Sim. Overall bowel cleansing score was considered adequate in 81.67% of the PEG+Asc and 80% of the PEG+Sim groups, respectively. Excellent and good ratings were recorded in 11.6% and 38.3% receiving PEG+Asc as compared with 26.6% and 23.3% of patients receiving PEG+Sim. Patient tolerability and safety were similar with both the preparations. According to our data, low-volume PEG+Asc has comparable efficacy, safety, and tolerability as high-volume PEG+Sim; therefore, it can be considered as a good alternative solution for bowel preparation. More improvements are necessary to achieve the target of a perfect preparation.
21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Detergent substances, other than soap, intended... Ingredients § 701.20 Detergent substances, other than soap, intended for use in cleansing the body. (a) In its definition of the term cosmetic, the Federal Food, Drug, and Cosmetic Act specifically excludes soap. The...
21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Detergent substances, other than soap, intended... Ingredients § 701.20 Detergent substances, other than soap, intended for use in cleansing the body. (a) In its definition of the term cosmetic, the Federal Food, Drug, and Cosmetic Act specifically excludes soap. The...
21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Detergent substances, other than soap, intended... Ingredients § 701.20 Detergent substances, other than soap, intended for use in cleansing the body. (a) In its definition of the term cosmetic, the Federal Food, Drug, and Cosmetic Act specifically excludes soap. The...
Ding, Wan; Xie, Ruibo; Sun, Binghai; Li, Weijian; Wang, Duo; Zhen, Rui
2016-01-01
Numerous studies have found that people tend to commit prosocial acts subsequent to previous immoral acts, as a response to the latter. This phenomenon is called moral cleansing or moral compensation. However, the specific mechanism how previous immoral acts motivate moral compensatory behaviors is still not fully understood. This study aimed to examine the roles of guilt and moral identity in the relation between previous immoral acts and subsequent prosocial behaviors to clarify the mechanism. Based on the extant research, the current study proposed a moderated mediation model to illustrate the process of moral cleansing. Specifically, a previous immoral act motivates guilt, which further leads to subsequent prosocial behaviors, while moral identity facilitates this process. The participants were primed by a recalling task (immoral act vs. a neutral event). The results support the hypothesized model and provide a framework that explains moral cleansing by integrating the roles of guilt and moral identity. These findings highlight the dynamic nature of people’s morality with regard to how people adapt moral behaviors to protect their moral self-image. PMID:27660617
Son, N T; Fleet, G H
1980-01-01
Oysters (Crassostrea commercials) harvested from major cultivation areas within the state of New South Wales, Australia, were commonly contaminated with low levels of the food-poisoning organisms Bacillus cereus, Clostridium perfringens, and Vibrio parahaemolyticus. Salmonella was found in oysters on only one occasion. These bacteria were cleansed from oysters during oyster purification by re-laying in a non-polluted waterway. Oysters were laboratory contaminated to levels in excess 1,000 cells per g with either B. cereus, C. perfringens, V. parahaemolyticus, Salmonella typhimurium, or S. senftenberg. These species were cleansed from such oysters during purification in a laboratory depuration unit that used ultraviolet light for sterilizing the depuration water. Escherichia coli was also cleansed from oysters under the same re-laying or depuration conditions so that its measurement alone could be used to indicate the cleansing of the above pathogenic species. The levels of these bacteria were also measured during the storage of oysters under conditions that occur during marketing. While B. cereus counts remained relatively stable during storage, the Salmonella spp. gradually decreased in numbers and C. perfringens rapidly died off. V. parahaemolyticus counts increased slightly during the first 4 days of storage, after which decreases occurred. PMID:6257164
Son, N T; Fleet, G H
1980-12-01
Oysters (Crassostrea commercials) harvested from major cultivation areas within the state of New South Wales, Australia, were commonly contaminated with low levels of the food-poisoning organisms Bacillus cereus, Clostridium perfringens, and Vibrio parahaemolyticus. Salmonella was found in oysters on only one occasion. These bacteria were cleansed from oysters during oyster purification by re-laying in a non-polluted waterway. Oysters were laboratory contaminated to levels in excess 1,000 cells per g with either B. cereus, C. perfringens, V. parahaemolyticus, Salmonella typhimurium, or S. senftenberg. These species were cleansed from such oysters during purification in a laboratory depuration unit that used ultraviolet light for sterilizing the depuration water. Escherichia coli was also cleansed from oysters under the same re-laying or depuration conditions so that its measurement alone could be used to indicate the cleansing of the above pathogenic species. The levels of these bacteria were also measured during the storage of oysters under conditions that occur during marketing. While B. cereus counts remained relatively stable during storage, the Salmonella spp. gradually decreased in numbers and C. perfringens rapidly died off. V. parahaemolyticus counts increased slightly during the first 4 days of storage, after which decreases occurred.
Developing New Methods for Microsampling and Sm/Nd Dating of Zoned Garnet
NASA Astrophysics Data System (ADS)
Pollington, A. D.; Baxter, E. F.
2007-12-01
Garnets provide one of the Earth Science community's most useful tools for studying rates, duration and timing of crustal processes. In this study we describe new techniques for fine sampling of multiple growth zones of garnet and Sm/Nd dating of each individual zone. We test these techniques on large (>5cm) garnets from a shear zone in the Tauern Window of Austria where we seek to quantify the growth history of garnet in a manner similar to dating tree rings. Microsampling permits a more precise quantification of duration, episodicity and kinetics of metamorphic reactions. Past studies of garnet growth duration - based on core and rim garnet ages - have been limited by sampling methods for extracting discrete, and accurate, growth zones. Modeling of radial growth symmetry in garnet shows that previous studies may underestimate garnet growth duration by as much as 50%. We are able to dramatically improve microsampling by using microdrilling guided by chemical maps of the garnet composition. This provides much improved precision and accuracy in sampling. By using chemical mapping of the garnet we can be sure that we are correctly sampling narrow (~500 micron wide) growth (i.e. age) zones rather than smearing and averaging multiple growth zones together. In principle, tens of growth zones (and ages) spanning the entire interval of garnet growth may be sampled and resolved. Microdrilled domains, the results of which are an ultrafine powder, are drilled and collected in water. Due to the adverse geochronological effect of unavoidable micro-inclusions in garnet, we have tested several partial dissolution techniques to cleanse the garnet of inclusions and yield higher 147Sm/144Nd and hence, more precise ages. Analysis of a finely crushed bulk Tauern Window garnet sample after HF/HClO3 cleansing indicates that 147Sm/144Nd at least as high as 0.89 is attainable in this particular sample, but cleansing efforts on microdrilled powders have thus far failed to yield such high ratios suggesting that the powders respond in unexpectedly different ways to our standard garnet cleansing procedures. Preliminary Sm/Nd age analysis of bulk garnet confirms a ~25Ma age for garnet growth. Progress in our inclusion cleansing procedures on microdrilled powders will be reported.
Tielsch, James M.; Darmstadt, Gary L.; Mullany, Luke C.; Khatry, Subarna K.; Katz, Joanne; LeClerq, Steven C.; Shrestha, Shardaram; Adhikari, Ramesh
2008-01-01
OBJECTIVE Hospital-based data from Africa suggest that newborn skin-cleansing with chlorhexidine may reduce neonatal mortality. Evaluation of this intervention in the communities where most births occur in the home has not been done. Our objective was to assess the efficacy of a 1-time skin-cleansing of newborn infants with 0.25% chlorhexidine on neonatal mortality. METHODS The design was a community-based, placebo-controlled, cluster-randomized trial in Sarlahi District in southern Nepal. Newborn infants were cleansed with infant wipes that contained 0.25% chlorhexidine or placebo solution as soon as possible after delivery in the home (median: 5.8 hours). The primary outcome was all-cause mortality by 28 days. After the completion of the randomized phase, all newborns in study clusters were converted to chlorhexidine treatment for the subsequent 9 months. RESULTS A total of 17 530 live births occurred in the enrolled sectors, 8650 and 8880 in the chlorhexidine and placebo groups, respectively. Baseline characteristics were similar in the treatment groups. Intention-to-treat analysis among all live births showed no impact of the intervention on neonatal mortality. Among live-born infants who actually received their assigned treatment (98.7%), there was a nonsignificant 11% lower neonatal mortality rate among those who were treated with chlorhexidine compared with placebo. Low birth weight infants had a statistically significant 28% reduction in neonatal mortality; there was no significant difference among infants who were born weighing ≥2500 g. After conversion to active treatment in the placebo clusters, there was a 37% reduction in mortality among low birth weight infants in the placebo clusters versus no change in the chlorhexidine clusters. CONCLUSIONS Newborn skin-wiping with chlorhexidine solution once, soon after birth, reduced neonatal mortality only among low birth weight infants. Evidence from additional trials is needed to determine whether this inexpensive and simple intervention could improve survival significantly among low birth weight infants in settings where home delivery is common and hygiene practices are poor. PMID:17210728
Cleansing and surface modifying agents on implants: fixation and related aspects of aesthetics.
Ling, B C; Gillings, B R
1995-01-01
With the prognosis of dental implant replacement of missing teeth becoming better each year, practitioners are focusing their attention on the aesthetic aspects of implantology. However, improvement in aesthetics is only possible with the improvement in implant technology, surgical techniques and prosthodontic procedures. This study aimed at evaluating the effects of various physical and chemical agents on the implant surface; with the view of obtaining increased surface area and biocompatibility. The study found that the treatment of air-aluminum oxide blasted implants using a mixture of 30% HNO3-5% HF acids produced a surface which meets the consideration of aesthetics for implants placed in the anterior maxillary region.
Xu, Hanyi; Bègue, Laurent; Bushman, Brad J.
2014-01-01
For centuries people have washed away their guilt by washing their hands. Do people need to wash their own hands, or is it enough to watch other people wash their hands? To induce guilt, we had participants write about a past wrong they had committed. Next, they washed their hands, watched a washing-hands video, or watched a typing-hands video. After the study was over, participants could help a Ph.D. student complete her dissertation by taking some questionnaires home and returning them within 3 weeks. Results showed that guilt and helping behavior were lowest among participants who washed their hands, followed by participants who watched a washing-hands video, followed by participants who watched a typing-hands video. Guilt mediated the effects of cleansing on helping. These findings suggest that washing one’s own hands, or even watching someone else wash their hands, can wash away one’s guilt and lead to less helpful behavior. PMID:24616686
Desmond, Nicola; Chiduo, Betty; Medard, Lemmy; Lees, Shelley S.; Vallely, Andrew; Francis, Suzanna C.; Ross, David A.; Hayes, Richard J.
2010-01-01
Intravaginal and menstrual practices may potentially influence results of trials of microbicides for HIV prevention through effects on the vaginal environment and on adherence to microbicide and placebo products. As part of the feasibility study for the Microbicides Development Programme Phase 3 trial of a vaginal microbicide in Mwanza, a variety of quantitative and qualitative methods were used to describe these practices, associations with behaviour and underlying social norms among women working in food and recreational facilities. Intravaginal cleansing by inserting fingers and either water alone or soap and water was thought necessary to remove “uchafu” (dirt), referring to vaginal secretions, including menstrual blood and post-coital discharge. Vaginal cleansing was carried out within 2 hours after 45% of sex acts. Sexual enhancement practices were less common. Intravaginal and menstrual practices and associated behaviours and demographic factors should be measured and monitored throughout microbicide trials to enable analyses of their impacts on microbicide effectiveness. PMID:20665101
RAPA: a novel in vitro method to evaluate anti-bacterial skin cleansing products.
Ansari, S A; Gafur, R B; Jones, K; Espada, L A; Polefka, T G
2010-04-01
Development of efficacious anti-bacterial skin cleansing products has been limited by the availability of a pre-clinical (in vitro) method to predict clinical efficacy adequately. We report a simple and rapid method, designated as rapid agar plate assay (RAPA), that uses the bacteriological agar surface as a surrogate substrate for skin and combines elements of two widely used in vivo (clinical) methods (Agar Patch and Cup Scrub). To simulate the washing of the human hand or forearm skin with the test product, trypticase soy agar plates were directly washed with the test product and rinsed under running tap water. After air-drying the washed plates, test bacteria (Staphylococcus aureus or Escherichia coli) were applied and the plates were incubated at 37 degrees C for 18-24 h. Using S. aureus as the test organism, anti-bacterial bar soap containing triclocarbanilide showed a strong linear relationship (R(2) = 0.97) between bacterial dose and their per cent reduction. A similar dose-response relationship (R(2) = 0.96) was observed for anti-bacterial liquid hand soap against E. coli. RAPA was able to distinguish between anti-bacterial products based on the nature and level of actives in them. In limited comparative tests, results obtained by RAPA were comparable with the results obtained by clinical agar patch and clinical cup scrub methods. In conclusion, RAPA provides a simple, rugged and reproducible in vitro method for testing the relative efficacy of anti-bacterial skin cleansing products with a likelihood of comparable clinical efficacy. Further testing is warranted to improve the clinical predictability of this method.
Stengel, Joel Z; Jones, David P
2008-09-01
Proper colonic cleansing prior to colonoscopy is paramount to ensuring complete mucosal visualization and polyp identification. In a double-blind fashion, we compared single-dose lubiprostone (24 microg) versus placebo pretreatment prior to a split-dose polyethylene glycol electrolyte (PEG-E) bowel preparation without dietary restriction to determine the efficacy, safety, and patient tolerability. Two hundred patients referred for outpatient colorectal cancer screening were randomized to receive a single-dose of unlabeled lubiprostone (24 microg) or placebo prior to a split-dose PEG-E bowel preparation without dietary restriction. The patients were surveyed prior to the colonoscopy on the tolerability of the bowel preparation, and any adverse events were recorded. The cleanliness of the colon was graded by the endoscopist during the procedure utilizing the Ottawa bowel preparation scale. One hundred ninety-one patients completed the study (95%). Split-dose PEG-E with lubiprostone pretreatment was found to be more effective at bowel cleansing in each segment of the colon when compared with split-dose PEG-E with placebo (P < 0.001). Patients enrolled in the lubiprostone treatment arm rated the overall experience as more tolerable (P 0.003) and complained of less abdominal bloating (P 0.049). No differences were observed between the groups for treatment-emergent side effects or adverse events (P > 0.05). Single-dose lubiprostone prior to split-dose PEG-E without dietary restriction significantly improves colonic mucosa visualization during colonoscopy and is well tolerated by patients.
Unique natural exopolysaccharides for biomimetic protective effect against urban pollution.
Borel, Magali; Lamarque, Elisabeth; Loing, Estelle
Through natural selection, living organisms have evolved well-adapted survival strategies over time. The shallow salt waters of Moorea lagoon are the site of accumulation of microbial mats called "Kopara," in the native Polynesian language. This unique ecosystem is rich in film-forming exopolysaccharides (EPSs) secreted by microorganisms within the biofilm, as a mean to protect themselves from environmental stress (strong ultraviolet [UV], pH, salinity … ). Using blue biotechnology, a manufacturing process was developed to obtain an EPS with skin benefits. The active ingredient (EPS-229) protects against urban pollution, including free radicals, heavy metals, hydrocarbons, and PM 2.5 (particulate matter with a size lower than 2.5 μm). The anti-lipid peroxidation action of EPS-229 was studied in an in vitro UVB-irradiated keratinocyte culture model, using lipophilic fluorescent probe. The chelating properties of EPS-229 were evaluated in tubo in the presence of cadmium and lead. The protective effect of EPS-229 on pollution-exposed skin explants was investigated through quantification of released malondialdehyde (MDA) and histological observation of skin morphology using optical microscopy. Clinical evaluation of the protective and cleansing efficacy of a water solution containing EPS-229 (0.02% and 0.01% w/v, respectively) was performed, against placebo, on a panel of 18 volunteers. For these studies, the forearms of volunteers were treated with EPS-229 before (anti-adhesion affect) or after (cleansing effect) application of PM 2.5 (iron particles of 1 μm). The presence of skin-adherent particles was observed and quantified by image analysis, using specific digital masks. In vitro , EPS-229 significantly protected keratinocyte cell membranes from lipid peroxidation. A decrease of 28% was achieved when a concentration of 0.001% w/v EPS-229 was applied to the cell culture. In tubo , EPS-229 also presented strong chelating properties. Maximal adsorption was estimated at 154 mg/g (1.37 mmol/g) of EPS-299 for cadmium and at 250 mg/g (1.21 mmol/g) of EPS-229 for lead. In the skin explant model of pollution exposure, EPS-229 (0.03% w/v) reduced MDA production by 44%, preserved cell integrity, improved dermal-epidermal cohesion, and normalized the collagen network. In vivo , treatment of skin with EPS-229 before exposure to PM 2.5 created a protective film limiting particle adhesion. When used in a cleansing solution after exposure to PM 2.5 , EPS-229 formed a mesh that entrapped particles and removed them from the skin surface. Inspired by the French Polynesia Kopara unique ecosystem, a bioactive exopolysaccharide (EPS-229) has been developed that offers protection from environmental aggression. As a biomimetic shield at the surface of the skin, EPS-229 provides an immediate multiprotective action that efficiently fights the harmful effects of urban pollution and smog.
Sikora, E; Michorczyk, P; Olszańska, M; Ogonowski, J
2015-12-01
The aim of this work was an elaboration of mild cleansing compositions, containing supercritical CO2 extract from strawberry seeds (SC-CO2 strawberry seed oil), as a moisturizing and skin-softening agent. The influence of concentration of the oil on user properties of shower/bath products was studied. A series of products (shower/bath cosmetics) composed mainly of mild surfactants (amphoacetates, sulfosuccinates, betaines) and containing different amounts of the oil (0.5 up to 5.0%) were prepared. For the stable products (formulations containing up to 2% of the oil), the influence of the SC-CO2 strawberry seed oil addition on the products' stability, foam ability, surface tension, pH and rheological properties was studied. Moreover, the skin compatibility and moisturizing efficiency of the cleansing products were recorded in a group of 15 volunteers (including 10 women and five men, aged 20-30 years), using skin diagnosis system AramoTS, Aram Huvis Co. Additionally, characterization of CO2 extract from strawberry seeds was performed. Measurements of the oil's analytical constants, that is acid value and saponification number, were conducted according to Polish Standard PN-EN ISO 660:2010 and PN-EN ISO 3657:2013, respectively. The oil concentration influences stability of the products. Only the formulations containing 0.5-2% of the extract have shown high stability. Moreover, used in the amount up to 2% the SC-CO2, strawberry seed oil does not affect significantly the cleansing and foaming properties of the products. The obtained shower/bath cosmetics showed good user properties and additionally good skin-moisturizing effect. The supercritical CO2 extract from strawberry seeds, rich source of unsaturated fatty acid, could be successfully used in the formulation of body washing compositions as a moisturizing and skin-softening agent. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Choi, Hyun-Seok; Chung, Jun-Won; Lee, Ji Won; Lim, Min Young; Park, Dong Kyun; Kim, Yoon Jae; Kwon, Kwang Ahn; Kim, Jung Ho
2016-04-01
This study was aimed to evaluate the efficacy and safety of two low-volume agents, polyethylene glycol (PEG)-3350 plus ascorbic acid (PEG + Asc) and sodium picosulfate with magnesium citrate (SPMC), for bowel preparation. We performed a prospective, endoscopist-blinded, single-center, randomized controlled trial comparing PEG + Asc with SPMC to evaluate the bowel cleansing efficacy of the two regimens using the modified Ottawa bowel preparation scale (OBPS) and the Aronchick scale. Patients' taste and overall tolerance were assessed with a questionnaire. In total, 200 patients were randomized to receive either PEG + Asc (n = 98) or SPMC (n = 102). Both treatments were similarly efficacious in bowel cleansing, based on the modified OBSP (PEG + Asc 4.01 ± 2.29 vs SPMC 3.86 ± 2.47, P = 0.62) and Aronchick scale (PEG + Asc 1.96 ± 0.70 vs SPMC 1.89 ± 0.70, P = 0.42). Patient-reported taste and tolerance of each regimen, as reported by the questionnaire, were significantly greater in the PEG + Asc group than in the SPMC group (P = 0.01). In terms of adverse events, dizziness was more frequently observed in the PEG + Asc group (P = 0.03), whereas nausea was more common in the SPMC group (P = 0.02). PEG + Asc and SPMC show similar efficacy for bowel preparation. However, patient's overall tolerance is higher in the PEG + Asc group. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.
ERIC Educational Resources Information Center
Mtibo, Charles; Kennedy, Neil; Umar, Eric
2011-01-01
Objective: A commonly cited, but unproven reason given for the rise in reported cases of child sexual abuse in Sub-Saharan Africa is the "HIV cleansing myth"--the belief that an HIV infected individual can be cured by having sex with a child virgin. The purpose of this study was to explore in Malawi the reasons given by convicted sex…
Irritancy ranking of 31 cleansers in the Indian market in a 24-h patch test.
Lakshmi, C; Srinivas, C R; Anand, C V; Mathew, A C
2008-08-01
Cleansing trends promise freshness, sensory and health benefits but may also be accompanied by an increase in soap-induced skin irritation. The aim of this study was to evaluate the irritant effect of 31 cleansers (28 bar soaps and 3 liquid cleansers) available in the Indian market. Eight percent w/v solutions of the soaps/cleansers were made and 30 microL of each of the solutions were applied to Finn chambers and occluded for 24 h along with distilled water (negative control) and 20% sodium dodecyl sulphate (SDS) as positive control. The sites were graded for erythema and scaling 30 min after removing the patches. The pH of each of the soap solutions was determined. Mean with SD and ANOVA (F-value) was computed separately for each soap/cleanser with respect to the two parameters, erythema and scaling. The total of the means for both the parameters, erythema and scaling was also computed. The cleansers were listed based on this total from the least irritant to the most irritant. The differences between soaps (F-value) was significant for erythema and scaling [erythema = 4.106 (P = 0.000); scaling = 6.006 (P = 0.000)]. Cetaphil cleansing lotion had the lowest erythema score of 0.25. Lowest scaling score of zero was recorded for Cetaphil cleansing lotion and Elovera moisturizing body wash. Aquasoft and Lifebuoy soaps had the highest erythema score of 2.13. Acnex had the highest scaling score of 1.75; Aquasoft, Hamam scrub bath soap and Naturepower sandal soaps were the next with a scaling score of 1.63. Cetaphil cleansing lotion, Aquaderm liquid soap, Dove bar soap and Elovera moisturizing body wash proved to be the least irritant cleansers with a total score of less than 1. The four most irritant soaps/cleansers had an average score of 3.65. The irritant potential of the majority of the cleansers fell between these extremes. The pH of all the soap/cleanser solutions was neutral to alkaline (pH 7-9) except that of Dove bar, Cetaphil cleansing lotion, Aquaderm liquid soap and Elovera moisturizing body wash which tested acidic (pH 5-6). The pH of the positive control--20% SDS, was acidic (pH 6). The difference in the irritancy potential between soaps/cleansers as determined by the 24-h patch test was significant. There were individual variations in the irritant potential of the soaps/cleansers in the volunteers, thus when the patient queries on what soap to use, it may be advisable to test each patient separately and educate him/her regarding the soaps/cleansers less likely to cause irritation. The limitations of the study was that it was single blind and non-randomized as all the 14 soap solutions were applied on 15 volunteers in the first panel and subsequently all the 17 soap solutions were applied on eight volunteers in the second panel. However, we could compare the irritant potential of 31 cleansers. The results of 24-h patch testing of 31 soaps/cleansers in the Indian market in two panels of 14 and 17 soaps/cleansers on 15 and eight volunteers, respectively, are presented.
Smajkić, A; Weine, S; Durić-Bijedić, Z; Boskailo, E; Lewis, J; Pavković, I
2001-01-01
The authors describe the use of three new antidepressants: Sertralilne, Paroxetine and Venlafaxine in treating Posttraumatic Stress Disorder and symptoms of Depression in adult Bosnian refugees victims of ethnic cleansing. 32 Bosnian refugees with PTSD and symptoms of Depression presenting for treatment of the mental health consequences of surviving ethnic cleansing, participated in a case series study. All subjects completed open trials of Sertraline (15), Paroxetine (12) or Venlafaxine (5), with standard clinical doses. Overall, Sertraline and Paroxetine yielded statistically significant improvement at 6 weeks in the total PTSD symptom severity, in each symptom cluster, in Beck Depression Inventory and in Global Assessment of Functioning. Venlafaxine produced statistically significant improvement at 6 weeks in the total PTSD symptom severity, in each symptom cluster and in Global Assessment of Functioning but did not yield significant improvement in symptoms of depression and had a high rate of side effects.
Nankabirwa, Victoria; Tylleskär, Thorkild; Tumuhamye, Josephine; Tumwine, James K; Ndeezi, Grace; Martines, José C; Sommerfelt, Halvor
2017-07-12
Yearly, nearly all the estimated worldwide 2.7 million neonatal deaths occur in low- and middle-income countries. Infections, including those affecting the umbilical cord (omphalitis), are a significant factor in approximately a third of these deaths. In fact, the odds of all-cause mortality are 46% higher among neonates with omphalitis than in those without. Five large randomized controlled trials in Asia and Sub-Saharan Africa (SSA) have examined the effect of multiple cord stump applications with 4% chlorhexidine (CHX) for at least 7 days on the risk of omphalitis and neonatal death. These studies, all community-based, show that multiple CHX applications reduced the risk of omphalitis. Of these trials, only one study from South Asia (the Bangladeshi study) and none from Africa examined the effect of a single application of CHX as soon as possible after birth. In this Bangladeshi trial, CHX led to a reduction in the risk of mild-moderate omphalitis and neonatal death. It is important, in an African setting, to explore the effect of a single application among health-facility births. A single application is programmatically much simpler to implement than daily applications for 7 days. Therefore, our study compares umbilical cord cleansing with a single application of 4% CHX at birth with dry cord care among Ugandan babies born in health facilities, on the risk of omphalitis and severe neonatal illness. The CHX study is a facility-based, individually randomized controlled trial that will be conducted among 4760 newborns in Uganda. The primary outcomes are severe illness and omphalitis during the neonatal period. Analysis will be by intention-to-treat. This study will provide novel evidence, from a Sub-Saharan African setting, of the effect of umbilical cord cleansing with a single application of 4% CHX at birth and identify modifiable risk factors for omphalitis. ClinicalTrials.gov, identifier: NCT02606565 . Registered on 12 November 2015.
Texture-based CAD improves diagnosis for low-dose CT colonography
NASA Astrophysics Data System (ADS)
Liang, Zhengrong; Cohen, Harris; Posniak, Erica; Fiore, Eddie; Wang, Zigang; Li, Bin; Andersen, Joseph; Harrington, Donald
2008-03-01
Computed tomography (CT)-based virtual colonoscopy or CT colonography (CTC) currently utilizes oral contrast solutions to tag the colonic fluid and possibly residual stool for differentiation from the colon wall and polyps. The enhanced image density of the tagged colonic materials causes a significant partial volume (PV) effect into the colon wall as well as the lumen space (filled with air or CO II). The PV effect on the colon wall can "bury" polyps of size as large as 5mm by increasing their image densities to a noticeable level, resulting in false negatives. It can also create false positives when PV effect goes into the lumen space. We have been modeling the PV effect for mixture-based image segmentation and developing text-based computer-aided detection of polyp (CADpolyp) by utilizing the PV mixture-based image segmentation. This work presents some preliminary results of developing and applying texture-based CADpolyp technique to low-dose CTC studies. A total of 114 studies of asymptomatic patients older than 50, who underwent CTC and then optical colonoscopy (OC) on the same day, were selected from a database, which was accumulated in the past decade and contains various bowel preparations and CT scanning protocols. The participating radiologists found ten polyps of greater than 5 mm from a total of 16 OC proved polyps, i.e., a detection sensitivity of 63%. They scored 23 false positives from the database, i.e., a 20% false positive rate. Approximately 70% of the datasets were marked as imperfect bowel cleansing and/or presence of image artifacts. The impact of imperfect bowel cleansing and image artifacts on VC performance is significant. The texture-based CADpolyp detected all the polyps with an average of 2.68 false positives per patient. This indicates that texture-based CADpolyp can improve the CTC performance in the cases of imperfect cleansed bowels and presence of image artifacts.
Use of macrogol 4000 in chronic constipation.
De Giorgio, R; Cestari, R; Corinaldesi, R; Stanghellini, V; Barbara, G; Felicani, C; Di Nardo, G; Cucchiara, S
2011-08-01
Chronic constipation is a common functional disorder of the gastrointestinal tract, affecting up to 35% of the general population, and especially the elderly. However, its definition as perceived by the patient can vary, making it difficult to understand the problem and find appropriate therapeutic measures. The approach to chronic constipation, thus, needs a thorough understanding of the patient's complaint and the main pathophysiological mechanism requiring treatment. Lifestyle changes do not usually meet with complete patient satisfaction. Other treatments include different types of laxatives. Of these, osmotic laxatives appear one of the most effective and are, therefore, frequently prescribed. This review will cover the topic of osmotic laxatives, specifically focusing on polyethylene glycol (PEG/macrogol 4000) in chronic constipation and as a key agent for bowel cleansing prior to colonoscopy. PEG formulations, including macrogol 4000, are safe, effective treatments for constipation, even in children and elderly patients. Macrogol 4000 may well be more palatable than combined formulations (macrogol 3350 with electrolytes), which could help improve adherence to the long-term treatment required for chronic constipation. PEG/macrogol is also recommended as an effective option for bowel cleansing prior to colonoscopy. The improved cost-effectiveness of macrogol over other commonly prescribed laxatives, such as lactulose, should be taken into consideration.
2014-01-01
Background It is well known that the use of denture cleansers can reduce Candida albicans biofilm accumulation; however, the efficacy of citric acid denture cleansers is uncertain. In addition, the long-term efficacy of this denture cleanser is not well established, and their effect on residual biofilms is unknown. This in vitro study evaluated the efficacy of citric acid denture cleanser treatment on C. albicans biofilm recolonization on poly(methyl methacrylate) (PMMA) surface. Methods C. albicans biofilms were developed for 72 h on PMMA resin specimens (n = 168), which were randomly assigned to 1 of 3 cleansing treatments (CTs) overnight (8 h). CTs included purified water as a control (CTC) and two experimental groups that used either a 1:5 dilution of citric acid denture cleanser (CT5) or a 1:8 dilution of citric acid denture cleanser (CT8). Residual biofilms adhering to the specimens were collected and quantified at two time points: immediately after CTs (ICT) and after cleaning and residual biofilm recolonization (RT). Residual biofilms were analyzed by quantifying the viable cells (CFU/mL), and biofilm architecture was evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Denture cleanser treatments and evaluation periods were considered study factors. Data were analyzed using two-way ANOVA and Tukey’s Honestly Significant Difference (HSD) test (α = 0.05). Results Immediately after treatments, citric acid denture cleansing solutions (CT5 and CT8) reduced the number of viable cells as compared with the control (p < 0.01). However, after 48 h, both CT groups (CT5 and CT8) showed biofilm recolonization (p < 0.01). Residual biofilm recolonization was also detected by CLSM and SEM analysis, which revealed a higher biomass and average biofilm thickness for the CT8 group (p < 0.01). Conclusion Citric acid denture cleansers can reduce C. albicans biofilm accumulation and cell viability. However, this CT did not prevent biofilm recolonization. PMID:24957210
NASA Technical Reports Server (NTRS)
1992-01-01
A water purification/recycling system developed by Photo-Catalytics, Inc. (PCI) for NASA is commercially available. The system cleanses and recycles water, using a "photo-catalysis" process in which light or radiant energy sparks a chemical reaction. Chemically stable semiconductor powders are added to organically polluted water. The powder absorbs ultraviolet light, and pollutants are oxidized and converted to carbon dioxide. Potential markets for the system include research and pharmaceutical manufacturing applications, as well as microchip manufacture and wastewater cleansing.
Spacecraft utensil/hand cleansing fixture. [for space shuttles
NASA Technical Reports Server (NTRS)
Rosener, A. A.; Jonkoniec, T. G.; Wilson, D. A.; Schulz, J. R.
1975-01-01
A system concept for an inflight utensil/hand cleansing fixture is described which includes the following features: (1) capability for efficient cleansing and rinsing of utensils or hands, and (2) provision for general waste fluid disposal. The design concept provides for the capability of functioning for a 30 day shuttle mission containing seven occupants/users. The long range goal is to provide a functioning system capable of operating for missions of at least 120 days. The fixture is a self-contained unit that can be installed in the standard water interface requirements. Service to the unit is a single source of unheated potable water and water is discharged from the unit into a single return waste connection. In addition, the design includes provisions for the intake and discharge of purge air and the discharge of evolved gases. Both the air and the gases are filtered or processed in the assembly before releasing them into the habitability area.
Shin, Ho-Sang; Lim, Hyun-Hee
2017-05-01
Seven halogenated volatile organic compounds (HVOCs) and two haloacetic acids were detected and quantified in 15 household products, including sodium hypochlorite, by gas chromatography-mass spectrometry (GC-MS). Chloroform was detected in a range of 0.2-30.2 mg kg -1 in all products, and carbon tetrachloride was observed in 13 samples in a range of 0.05-352 mg kg -1 . Dichloroacetic acid and trichloroacetic acid were also detected up to 94 and 146 mg kg -1 in household products. The estimated human exposures of chloroform, carbon tetrachloride, dichloroacetic acid and trichloroacetic acid were calculated to 0.041, 0.240, 0.913 and 2.39 mg/kg/day by the exposure algorithm from the Japan National Institute of Technology and Evaluation, respectively. According to the calculated result, the total estimated human exposure of chloroform were determined to exceed the tolerable concentration of inhalation exposure presented by the World Health Organization. The DBPs should be controlled to the lowest concentrations in the chlorine-containing household cleansing products. Copyright © 2017 Elsevier Ltd. All rights reserved.
Tazrart, A; Bolzinger, M A; Lamart, S; Coudert, S; Angulo, J F; Jandard, V; Briançon, S; Griffiths, N M
2018-07-01
Skin contamination by alpha-emitting actinides is a risk to workers during nuclear fuel production and reactor decommissioning. Also, the list of items for potential use in radiological dispersal devices includes plutonium and americium. The actinide chemical form is important and solvents such as tributyl phosphate, used to extract plutonium, can influence plutonium behavior. This study investigated skin fixation and efficacy of decontamination products for these actinide forms using viable pig skin in the Franz cell diffusion system. Commonly used or recommended decontamination products such as water, cleansing gel, diethylenetriamine pentaacetic acid, or octadentate hydroxypyridinone compound 3,4,3-LI(1,2-HOPO), as well as diethylenetriamine pentaacetic acid hydrogel formulations, were tested after a 2-h contact time with the contaminant. Analysis of skin samples demonstrated that more plutonium nitrate is bound to skin as compared to plutonium-tributyl phosphate, and fixation of americium to skin was also significant. The data show that for plutonium-tributyl phosphate all the products are effective ranging from 80 to 90% removal of this contaminant. This may be associated with damage to the skin by this complex and suggests a mechanical/wash-out action rather than chelation. For removal of americium and plutonium, both Trait Rouge cleansing gel and diethylenetriamine pentaacetic acid are better than water, and diethylenetriamine pentaacetic acid hydrogel is better than Osmogel. The different treatments, however, did not significantly affect the activity in deeper skin layers, which suggests a need for further improvement of decontamination procedures. The new diethylenetriamine pentaacetic acid hydrogel preparation was effective in removing americium, plutonium, and plutonium-tributyl phosphate from skin; such a formulation offers advantages and thus merits further assessment.
Deep multi-spectral ensemble learning for electronic cleansing in dual-energy CT colonography
NASA Astrophysics Data System (ADS)
Tachibana, Rie; Näppi, Janne J.; Hironaka, Toru; Kim, Se Hyung; Yoshida, Hiroyuki
2017-03-01
We developed a novel electronic cleansing (EC) method for dual-energy CT colonography (DE-CTC) based on an ensemble deep convolution neural network (DCNN) and multi-spectral multi-slice image patches. In the method, an ensemble DCNN is used to classify each voxel of a DE-CTC image volume into five classes: luminal air, soft tissue, tagged fecal materials, and partial-volume boundaries between air and tagging and those between soft tissue and tagging. Each DCNN acts as a voxel classifier, where an input image patch centered at the voxel is generated as input to the DCNNs. An image patch has three channels that are mapped from a region-of-interest containing the image plane of the voxel and the two adjacent image planes. Six different types of spectral input image datasets were derived using two dual-energy CT images, two virtual monochromatic images, and two material images. An ensemble DCNN was constructed by use of a meta-classifier that combines the output of multiple DCNNs, each of which was trained with a different type of multi-spectral image patches. The electronically cleansed CTC images were calculated by removal of regions classified as other than soft tissue, followed by a colon surface reconstruction. For pilot evaluation, 359 volumes of interest (VOIs) representing sources of subtraction artifacts observed in current EC schemes were sampled from 30 clinical CTC cases. Preliminary results showed that the ensemble DCNN can yield high accuracy in labeling of the VOIs, indicating that deep learning of multi-spectral EC with multi-slice imaging could accurately remove residual fecal materials from CTC images without generating major EC artifacts.
Surface characteristics of clinically used dental implant screws
NASA Astrophysics Data System (ADS)
Han, Myung-Ju; Choe, Han-Cheol; Chung, Chae-Heon
2005-12-01
Surface alteration of implant screws after function may be associated with mechanicalffailure. This type of metal fatigue appears to be the most common cause of structural failure. The purpose of this study was to evaluate surface alteration of implant screws after function through an examination of used and unused implant screws via scanning electron microscopy (SEM). In this study, abutment screws (Steri-oss, 3i, USA), gold retaining screws (3i, USA), and titanium retaining screws (3i, USA) were retrieved from patients, New, unused abutment, and retaining screws were prepared for a control group. Each of the old, used screws was retrieved with a screwdriver. The retrieved implant complex of a Steri-oss system was also prepared for this study. SEM investigation and energy dispersive spectroscopy (EDS) analysis of the abutment and retaining screws were then performed, as well as SEM investigation of a cross-sectioned sample of the retrieved implant complex in the case of new, unused implant screws, as-manufactured circumferential grooves were regularly examined and screw threads were sharply maintained. Before ultrasonic cleansing of old, used implant screws, there was a large amount of debris accumulation and corrosion products. After ultrasonic cleansing of old, used implant screws, circumferential grooves were examined were found to be randomly deepened and scratching increased. Also, dull screw fhreads were observed. More surface alterations after function were observed in titanium screws than in gold screws. Furthermore, more surface alteration was observed when the screws were retrieved with a driver than without a driver. These surface alterations after function may result in screw instability. Regular cleansing and exchange of screws is therefore recommended. We also recommend the use of gold screws over titanium screws, and careful manipulation of the driver.
Hand Washing Induces a Clean Slate Effect in Moral Judgments: A Pupillometry and Eye-Tracking Study
Kaspar, Kai; Krapp, Vanessa; König, Peter
2015-01-01
Physical cleansing is commonly understood to protect us against physical contamination. However, recent studies showed additional effects on moral judgments. Under the heading of the “Macbeth effect” direct links between bodily cleansing and one’s own moral purity have been demonstrated. Here we investigate (1) how moral judgments develop over time and how they are altered by hand washing, (2) whether changes in moral judgments can be explained by altered information sampling from the environment, and (3) whether hand washing affects emotional arousal. Using a pre-post control group design, we found that morality ratings of morally good and bad scenes acquired more extreme values in the control group over time, an effect that was fully counteracted by intermediate hand washing. This result supports the notion of a clean slate effect by hand washing. Thereby, eye-tracking data did not uncover differences in eye movement behavior that may explain differences in moral judgments. Thus, the clean slate effect is not due to altered information sampling from the environment. Finally, compared to the control group, pupil diameter decreased after hand washing, thus demonstrating a direct physiological effect. The results shed light on the physiological mechanisms behind this type of embodiment phenomenon. PMID:25994083
Cai, Wenli; Zhang, Da; Lee, June-Goo; Shirai, Yu; Kim, Se Hyung; Yoshida, Hiroyuki
2013-01-01
The purpose of our study was to measure the dual-energy index (DEI) value of colonic luminal air in both phantom and clinical fecal-tagging dual-energy computed tomography (CT) colonography (DE-CTC) images and to demonstrate its impact on dual-energy electronic cleansing. For the phantom study, a custom-ordered colon phantom was scanned by a dual-energy CT scanner (SOMATON Definition Flash; Siemens Healthcare, Forchheim, Germany) at two photon energies: 80 and 140 kVp. Before imaging, the phantom was filled with a 300-mL mixture of simulated fecal materials tagged by a nonionic iodinated contrast agent at three contrast concentrations: 20, 40, and 60 mg/mL. Ten regions-of-interest (ROIs) were randomly placed in each of the colonic luminal air, abdominal fat, bony structure, and tagged material in each scan. For the clinical study, 22 DE-CTC (80 and 140 kVp) patient cases were collected, who underwent a low-fiber, low-residue diet bowel preparation and orally administered iodine-based fecal tagging. Twenty ROIs were randomly placed in each of the colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material in each scan. For each ROI, the mean CT values in both 80- and 140-kVp images were measured, and then its DEI was calculated. In the phantom study, the mean DEI values of luminal air were 0.270, 0.298, 0.386, and 0.402 for the four groups of tagging conditions: no tagged material and tagged with three groups of contrast concentrations at 20, 40, and 60 mg/mL. In the clinical study, the mean DEI values were 0.341, -0.012, -0.002, and 0.188 for colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material, respectively. In our study, we observed that the DEI values of colonic luminal air in DE-CTC images (>0.10) were substantially higher than the theoretical value of 0.0063. In addition, the observed DEI values of colonic luminal air were significantly higher than those of soft tissue. These findings have an important impact on electronic cleansing: it may provide an effective means of differentiating colonic soft-tissue structures from the air-tagging mixture caused by the partial volume effect and thus of minimizing the cleansing artifacts.
Achieving the best bowel preparation for colonoscopy
Parra-Blanco, Adolfo; Ruiz, Alex; Alvarez-Lobos, Manuel; Amorós, Ana; Gana, Juan Cristóbal; Ibáñez, Patricio; Ono, Akiko; Fujii, Takahiro
2014-01-01
Bowel preparation is a core issue in colonoscopy, as it is closely related to the quality of the procedure. Patients often find that bowel preparation is the most unpleasant part of the examination. It is widely accepted that the quality of cleansing must be excellent to facilitate detecting neoplastic lesions. In spite of its importance and potential implications, until recently, bowel preparation has not been the subject of much study. The most commonly used agents are high-volume polyethylene glycol (PEG) electrolyte solution and sodium phosphate. There has been some confusion, even in published meta-analyses, regarding which of the two agents provides better cleansing. It is clear now that both PEG and sodium phosphate are effective when administered with proper timing. Consequently, the timing of administration is recognized as one of the central factors to the quality of cleansing. The bowel preparation agent should be administered, at least in part, a few hours in advance of the colonoscopy. Several low volume agents are available, and either new or modified schedules with PEG that usually improve tolerance. Certain adjuvants can also be used to reduce the volume of PEG, or to improve the efficacy of other agents. Other factors apart from the choice of agent can improve the quality of bowel cleansing. For instance, the effect of diet before colonoscopy has not been completely clarified, but an exclusively liquid diet is probably not required, and a low-fiber diet may be preferable because it improves patient satisfaction and the quality of the procedure. Some patients, such as diabetics and persons with heart or kidney disease, require modified procedures and certain precautions. Bowel preparation for pediatric patients is also reviewed here. In such cases, PEG remains the most commonly used agent. As detecting neoplasia is not the main objective with these patients, less intensive preparation may suffice. Special considerations must be made for patients with inflammatory bowel disease, including safety and diagnostic issues, so that the most adequate agent is chosen. Identifying neoplasia is one of the main objectives of colonoscopy with these patients, and the target lesions are often almost invisible with white light endoscopy. Therefore excellent quality preparation is required to find these lesions and to apply advanced methods such as chromoendoscopy. Bowel preparation for patients with lower gastrointestinal bleeding represents a challenge, and the strategies available are also reviewed here. PMID:25548470
2010-04-01
options at his disposal to back up other efforts. The global strike capabilities outlined in this paper are not particularly palatable . They would...against Serbia as part of operation Allied Force. During the air war over the ethnic cleansing of Albanian Muslims in Kosovo, the coalition forces...convince the Serb leader, Slobodan Milosevic, to end the cleansing by his troops. The top Air Force leader in Europe believed that the lack of
Resolving Kirkuk: Lessons Learned from Settlements of Earlier Ethno-Territorial Conflicts
2012-01-01
interests, the Federation feared that the loss of Brčko would be seen as rewarding Serb-inflicted ethnic cleansing . The status of Brčko was thus a...governance arrangements for Mostar began with institutionalization of the status quo, which reflected ethnic cleansing during the war. The starting point...both made significant commitments that made the GFA palatable to both Unionists and Republicans. In Brčko, the international supervisor was given
Electronic cleansing for CT colonography using spectral-driven iterative reconstruction
NASA Astrophysics Data System (ADS)
Nasirudin, Radin A.; Näppi, Janne J.; Hironaka, Toru; Tachibana, Rie; Yoshida, Hiroyuki
2017-03-01
Dual-energy computed tomography is used increasingly in CT colonography (CTC). The combination of computer-aided detection (CADe) and dual-energy CTC (DE-CTC) has high clinical value, because it can detect clinically significant colonic lesions automatically at higher accuracy than does conventional single-energy CTC. While CADe has demonstrated its ability to detect small polyps, its performance is highly dependent on several factors, including the quality of CTC images and electronic cleansing (EC) of the images. The presence of artifacts such as beam hardening and image noise in ultra-low-dose CTC can produce incorrectly cleansed colon images that severely degrade the detection performance of CTC for small polyps. Also, CADe methods are very dependent on the quality of input images and the information about different tissues in the colon. In this work, we developed a novel method to calculate EC images using spectral information from DE-CTC data. First, the ultra-low dose dual-energy projection data obtained from a CT scanner are decomposed into two materials, soft tissue and the orally administered fecal-tagging contrast agent, to detect the location and intensity of the contrast agent. Next, the images are iteratively reconstructed while gradually removing the presence of tagged materials from the images. Our preliminary qualitative results show that the method can cleanse the contrast agent and tagged materials correctly from DE-CTC images without affecting the appearance of surrounding tissue.
[The myth of virgin cleansing: Latest news on an archaic magico-religious practice].
Charlier, P; Bou Abdallah, F; Brun, L; Hoang-Oppermann, V; Deo, S; Mostefai-Dulac, Y; Mamzer, M-F; Hervé, C
2018-03-01
In the medical anthropology section of the Nanterre Hospital (France) for migrants and refugees, three cases were recorded of "virgin cleansing" in sub-Saharan African countries. These consisted of sexual assaults (2 instances of rape and 1 of sexual interference) on sexually immature females (young girls) by patients with sexually transmitted infections (mainly HIV, syphilis) hoping they might thereby be cured. These particularly atrocious hetero-aggressive sexual practices based on magical arguments are unfortunately universal and are not limited to a specific culture. At the medical anthropology level, the belief in cleansing by virgins is based on the notion that the patient is dirty and impure. In the same way that emetics and/or laxatives are prescribed in the case of intestinal disorders (to "eliminate" the disease), some subjects use diuretics for urinary abnormalities or, literally, "clean vaginas (or anuses)" to purge their own miasma. The rising tide of population migrations (some of whom carry chronic infections), refugee camps, prolonged incarcerations, etc., makes observations of such phenomena increasingly frequent. Belief in cleansing by virgins (and the fatal consequences thereof) will be difficult to eradicate. The education of populations and health professionals should promote absolute respect for the body of children, and, more generally, of others, particularly since at this time of increasingly marked migratory flows, this problem sadly risks becoming widespread. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Kim, Hyoung Jun; Kim, Tae Oh; Shin, Bong Chul; Woo, Jae Gon; Seo, Eun Hee; Joo, Hee Rin; Heo, Nae-Yun; Park, Jongha; Park, Seung Ha; Yang, Sung Yeon; Moon, Young Soo; Shin, Jin-Yong; Lee, Nae Young
2012-01-01
Currently, a split-dose of polyethylene glycol (PEG) is the mainstay of bowel preparation due to its tolerability, bowel-cleansing action, and safety. However, bowel preparation with PEG is suboptimal because residual fluid reduces the polyp detection rate and requires a more thorough colon inspection. The aim of our study was to demonstrate the efficacy of a sufficient dose of prokinetics on bowel cleansing together with split-dose PEG. A prospective endoscopist-blinded study was conducted. Patients were randomly allocated to two groups: prokinetic with split-dose PEG or split-dose PEG alone. A prokinetic [100 mg itopride (Itomed)], was administered twice simultaneously with each split-dose of PEG. Bowel-cleansing efficacy was measured by endoscopists using the Ottawa scale and the segmental fluidity scale score. Each participant completed a bowel preparation survey. Mean scores from the Ottawa scale, segmental fluid scale, and rate of poor preparation were compared between both groups. Patients in the prokinetics with split-dose PEG group showed significantly lower total Ottawa and segmental fluid scores compared with patients in the split-dose of PEG alone group. A sufficient dose of prokinetics with a split-dose of PEG showed efficacy in bowel cleansing for morning colonoscopy, largely due to the reduction in colonic fluid. Copyright © 2012 S. Karger AG, Basel.
Assessment of post-contamination treatments affecting different bonding stages to dentin
Elkassas, Dina; Arafa, Abla
2016-01-01
Objectives: To assess the effect of cleansing treatments following saliva and blood contamination at different bonding stages to dentin. Materials and Methods: Labial surfaces of 168 permanent maxillary central incisors were ground flat exposing superficial dentin. Specimens were divided into: uncontaminated control (A), contamination after etching (B), contamination after adhesive application (C), contamination after adhesive polymerization (D). Groups were further subdivided according to cleansing treatments into: rinsing (B1, C1, D1), re-etching (B2, D3), sodium hypochlorite application (B3), ethyl alcohol application (C2), acetone application (C3), rinsing and rebonding (D2), re-etching and rebonding (D4). Composite microcylinders were bonded to treated substrates and shear loaded micro-shear bond strength (μSBS) until failure and treated surfaces were examined with scanning electron microscope. Debonded surfaces were classified as adhesive, cohesive or mixed failure. The data were analyzed using one-way ANOVA and Tukey's post hoc test. Results: The μSBS values were ranked as follow; Group B: A > B3 > B2 > B1 > B, Group C: A > C3 > C2 > C1 > C, Group D: A > D4 > D1 = D2 ≥ D3. Debonded surfaces showed adhesive failure in Group B while cohesive failure in Groups C and D. Conclusions: Cleansing treatments differ according to bonding step; re-etching then rebonding suggested if etched substrate or polymerized adhesive were contaminated while acetone application decontaminated affected unpolymerized adhesive. PMID:27403048
USDA-ARS?s Scientific Manuscript database
Phytoremediation is a cost-effective and minimally invasive technology to cleanse soils contaminated with heavy metals. However, few plant species are suitable for phytoremediation of metals such as cadmium (Cd). Genetic engineering offers a powerful tool to generate plants that can hyperaccumulate ...
Combination could be another tool for bowel preparation?
Soh, Jae Seung; Kim, Kyung-Jo
2016-01-01
Optimal bowel preparation increases the cecal intubation rate and detection of neoplastic lesions while decreasing the procedural time and procedural-related complications. Although high-volume polyethylene glycol (PEG) solution is the most frequently used preparation for bowel cleansing, patients are often unwilling to take PEG solution due to its large volume, poor palatability, and high incidence of adverse events, such as abdominal bloating and nausea. Other purgatives include osmotic agents (e.g., sodium phosphate, magnesium citrate, and sodium sulfate), stimulant agents (e.g., senna, bisacodyl, and sodium picosulfate), and prokinetic agents (e.g., cisapride, mosapride, and itopride). A combination of PEG with an osmotic, stimulant, or prokinetic agent could effectively reduce the PEG solution volume and increase patients’ adherence. Some such solutions have been found in several published studies to not be inferior to PEG alone in terms of bowel cleansing quality. Although combination methods showed similar efficacy and safety, the value of these studies is limited by shortcomings in study design. New effective and well-tolerated combination preparations are required, in addition to rigorous new validated studies. PMID:26973388
Perry, Brian; Oluoch, Lennah; Agot, Kawango; Taylor, Jamilah; Onyango, Jacob; Ouma, Lilian; Otieno, Caroline; Wong, Christina; Corneli, Amy
2014-01-01
Introduction The customs of widow cleansing and widow inheritance are practiced in several communities throughout sub-Saharan Africa. In the Nyanza Province of Kenya, according to tradition, Luo widows are expected to engage in sexual intercourse with a “cleanser,” without the use of a condom, in order to remove the impurity ascribed to her after her husband's death. Luo couples, including widows, are also expected to engage in sex preceding specific agricultural activities, building homes, funerals, weddings, and other significant cultural and social events. Widows who are inherited for the purpose of fulfilling cultural obligation have a higher prevalence of HIV than those who remain un-inherited or are inherited for the purpose of companionship. Methods As part of a larger descriptive qualitative study to inform study procedures for FEM-PrEP, an HIV prevention pre-exposure prophylaxis clinical trial, we conducted 15 semi-structured interviews (SSIs) with widows, 15 SSIs with inheritors, and four focus group discussions with widows in the Bondo and Rarieda districts in Nyanza Province to explore the HIV risk context within widow cleansing and inheritance practices. Thematic qualitative analysis was used to analyze the data. Results The majority of widows reported in the demographic questionnaire being inherited, and most widows in the SSIs described participating in the cleansing ritual. We identified two main themes related to HIV prevention within the context of widow cleansing and inheritance: 1) widows must balance limiting their risk for HIV infection with meeting cultural expectations and ensuring that their livelihood needs are met, and 2) sexual abstinence undermines cultural expectations in widowhood while the use of condoms is deemed inappropriate in fulfilling culturally prescribed sexual rituals, and is often beyond the widow's ability to negotiate. Conclusions Women-controlled HIV prevention methods such as antiretroviral-based oral pre-exposure prophylaxis, vaginal gels, and vaginal rings are needed for HIV-negative widows who engage in sexual rituals related to widowhood. PMID:24973041
Perry, Brian; Oluoch, Lennah; Agot, Kawango; Taylor, Jamilah; Onyango, Jacob; Ouma, Lilian; Otieno, Caroline; Wong, Christina; Corneli, Amy
2014-01-01
The customs of widow cleansing and widow inheritance are practiced in several communities throughout sub-Saharan Africa. In the Nyanza Province of Kenya, according to tradition, Luo widows are expected to engage in sexual intercourse with a "cleanser," without the use of a condom, in order to remove the impurity ascribed to her after her husband's death. Luo couples, including widows, are also expected to engage in sex preceding specific agricultural activities, building homes, funerals, weddings, and other significant cultural and social events. Widows who are inherited for the purpose of fulfilling cultural obligation have a higher prevalence of HIV than those who remain un-inherited or are inherited for the purpose of companionship. As part of a larger descriptive qualitative study to inform study procedures for FEM-PrEP, an HIV prevention pre-exposure prophylaxis clinical trial, we conducted 15 semi-structured interviews (SSIs) with widows, 15 SSIs with inheritors, and four focus group discussions with widows in the Bondo and Rarieda districts in Nyanza Province to explore the HIV risk context within widow cleansing and inheritance practices. Thematic qualitative analysis was used to analyze the data. The majority of widows reported in the demographic questionnaire being inherited, and most widows in the SSIs described participating in the cleansing ritual. We identified two main themes related to HIV prevention within the context of widow cleansing and inheritance: 1) widows must balance limiting their risk for HIV infection with meeting cultural expectations and ensuring that their livelihood needs are met, and 2) sexual abstinence undermines cultural expectations in widowhood while the use of condoms is deemed inappropriate in fulfilling culturally prescribed sexual rituals, and is often beyond the widow's ability to negotiate. Women-controlled HIV prevention methods such as antiretroviral-based oral pre-exposure prophylaxis, vaginal gels, and vaginal rings are needed for HIV-negative widows who engage in sexual rituals related to widowhood.
Bending the Spear: The Campaign Against the Lord’s Resistance Army
2017-12-01
cleansing rituals alone. When people were killed, he purified them by himself.65 New members had to undertake rites of passage to be cleansed of witchcraft...of faith in his spiritual powers , and so would abduct UPDA soldiers and force them into the LRA when he encountered them away from their units.70...against Kony. Kony wanted to start an Acholi war. He wanted a Luo republic, wanted it to go to the Nile. People turned against him. When they said
Safder, Shaista; Demintieva, Yulia; Rewalt, Mary; Elitsur, Yoram
2008-12-01
Colon preparation for a colonoscopy in children is a difficult task because of the unpalatable taste and large volume of cleansing solution that needs to be consumed to ensure a clean colon. Consequently, an unprepared colon frequently occurs in routine practices, which causes early termination and a repeated procedure. (1) To assess the effectiveness of polyethylene glycol solution (PEG 3350) in preparing the colon of children scheduled for a colonoscopy and (2) to investigate clinical markers associated with an adequate colon preparation before a colonoscopy. A total of 167 children scheduled for a colonoscopy. In a prospective study, children scheduled for a colonoscopy were given PEG 3350 solution (1.5 g/kg per day, up to 100 g/d) over a 4-day preparation period. Each day, a simple questionnaire that documents the amount of liquid consumed, adverse effects, and the number and consistency of stool was completed by the parents. After a colonoscopy procedure, the colon preparation was assigned a number grade. The data were later assessed and were compared to determine the association between the grade of cleansing and the frequency and/or consistency of stool during preparation. Colon preparation was completed in 149 children, 133 of whom were adequately prepared. Inadequate preparation was found in 16 children; the procedure was terminated prematurely in 2 of these patients because of unacceptable conditions. No significant adverse effects were noted. A number of >or=5 stools/d, and liquid stool consistency in the last 2 days of preparation were associated with adequate colon preparation. PEG 3350 solution is safe, efficacious, and tolerable for children. Stool frequency and consistency in the last 2 days of preparation were excellent markers (positive predictive value 91%-95%), which predict an adequately clean colon before a colonoscopy in children.
MiraLAX is not as effective as GoLytely in bowel cleansing before screening colonoscopies.
Hjelkrem, Michael; Stengel, Joel; Liu, Mark; Jones, David P; Harrison, Stephen A
2011-04-01
Successful colonoscopies require good bowel preparations-poor bowel preparations can increase medical costs, rates of missed lesions, and procedure duration. The combination of polyethylene glycol (PEG) 3350 without electrolytes (MiraLAX; Schering-Plough Healthcare Products, Inc, Kenilworth, NJ) and 64 oz of Gatorade (PepsiCo, Inc, Purchase, NY) has gained popularity as a bowel preparation regimen. However, the efficacy and tolerability of this approach has not been compared with standard bowel preparations in clinical trials. We compared split-dose (PEG) 3350 with electrolytes (GoLytely; Braintree Laboratories, Inc, Braintree, MA) with split-dose MiraLAX alone and in combination with pretreatment medications (bisacodyl or lubiprostone) to determine the efficacy and patient tolerability of MiraLAX as an agent for bowel preparation. We performed a prospective, randomized, blinded, controlled trial at a tertiary care center. Patients (n=403) were randomly assigned to groups given GoLytely, MiraLAX, MiraLAX with bisacodyl (10 mg), or MiraLAX with lubiprostone (24 μg). MiraLAX was combined with 64 oz of Gatorade. All patients were surveyed regarding preparation satisfaction and tolerability. The Ottawa bowel preparation scale was used to grade colon cleanliness. GoLytely was more effective at bowel cleansing (average Ottawa score, 5.1) than MiraLAX alone (average Ottawa score, 6.9) or in combination with lubiprostone (average Ottawa score, 6.8), or bisacodyl (average Ottawa score, 6.3) (P<.001). MiraLAX was associated with a trend toward longer procedure duration (P=.096). Groups given MiraLAX rated the overall experience as more satisfactory than those given GoLytely (P<.001). There were no differences between polyp detection rates (P=.346) or adverse events (P=.823). Split-dose MiraLAX in 64 oz of Gatorade is not as effective as 4 L split-dose GoLytely in bowel cleansing for screening colonoscopies. Copyright © 2011 AGA Institute. Published by Elsevier Inc. All rights reserved.
Choi, Hong Seok; Shim, Chan Sup; Kim, Gyu Won; Kim, Jung Seok; Lee, Sun-Young; Sung, In-Kyung; Park, Hyung Seok; Kim, Jeong Hwan
2014-10-01
Many patients report discomfort because of the unpleasant taste of bowel preparation solutions. This study aimed to determine whether adding orange juice to 2 L of polyethylene glycol plus ascorbic acid is effective for reducing patient discomfort and improving palatability during bowel preparation. This was a single-blinded, randomized controlled trial. The study was conducted at a tertiary referral hospital and a generalized hospital. Consecutive outpatients and inpatients were randomly allocated to drink 2 L of polyethylene glycol-ascorbic acid or 2 L of polyethylene glycol-ascorbic acid with orange juice in a single dose or a split dose. Tolerability, palatability score, willingness, and related adverse events were investigated by questionnaires. Bowel cleansing was rated using the Aronchick scale. Each score was graded on a 5-point scale. A total of 107 patients, 53 in the orange juice group and 54 in the polyethylene glycol-ascorbic acid group who underwent elective colonoscopy were enrolled. The palatability score (mean ± SD) was higher in the orange juice group than in the control group (2.36 ± 0.76 vs 1.78 ± 0.88; p = 0.005). Nausea was less frequent in the orange juice group (26.4% vs 59.3%; p = 0.001). Total amount of bowel preparation ingested was not significantly different between the groups (p = 0.44). The bowel preparation score (mean ± SD) was not significantly different (1.49 ± 0.80 vs 1.43 ± 0.77; p = 0.94). Willingness to repeat the same process was higher in the orange juice group (90.4% vs 66.7%; p = 0.003). This study is limited because only ambulatory patients were enrolled. Orange juice intake before drinking 2 L of polyethylene glycol-ascorbic acid for colonoscopy can reduce patient discomfort, resulting in improved acceptability and patient compliance. This method is as effective for bowel cleansing as polyethylene glycol.
Developing a Mobile App for Prevention and Treatment of Pressure Injuries.
Salomé, Geraldo Magela; Ferreira, Lydia Masako
2018-02-01
This descriptive study describes the planning and development of a mobile application (app) for prevention and treatment of pressure injuries for use by providers in a university research center. The app delineates risk factors for pressure injury development, provides an evaluation of the wound, recommends wound cleansing procedures, performs pressure injury staging, and recommends treatment interventions. A mobile app was developed using a contextualized instructional design, which involves a constructivist proposal and planning, developing, and applying specific didactic situations, thus incorporating mechanisms that favor contextualization. A literature search was conducted to identify relevant studies for the construction of the mobile app. The development process involved the selection of app tools, definition of the navigation structure, and planning of the environment configuration. The environment for downloading the app software on the Internet and installing it on the mobile device was created. The literature search yielded 18 articles, 2 books, and 1 master's degree thesis. A mobile app was created with an easy-to-use graphic interface. The app stores the patient's demographic characteristics and provides an evaluation of his/her wound, a list of risk factors for pressure injury development, wound cleansing procedures, and treatment interventions. The developed app may be useful in clinical practice, helping to prevent pressure injuries and promote select nursing interventions for the treatment of patients with pressure injury.
Zhou, Jieqiong; Tang, Xiaowei; Wang, Jing; Chen, Zhenyu; Wang, Xinying; Jiang, Bo
2017-08-01
Bowel preparation regimens for colon capsule endoscopy are not yet standardized since they are not well optimized. The aim of the present study was to evaluate the feasibility of a novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy. A total of 31 patients were prospectively enrolled. In the novel regimen, on the day prior to examination, a low-fiber diet was permitted, 5 mg mosapride citrate was administered twice (1 h prior to lunch and supper) and 1 l polyethylene glycol was administered in the evening. On the day of the examination, an additional 1 l polyethylene glycol, 5 mg mosapride citrate and 200 mg simethicone were administered before capsule ingestion. Polyethylene glycol booster (0.5 l) was administered twice, at 1 and 4 h following capsule ingestion. Colon cleansing levels, ileocecal valve transit time and completion rate were evaluated. A total of 29 patients were included in the final analysis, 90% of whom achieved adequate preparation of the overall colon. Ileocecal valve transit time was 2.35±0.82 h and completion rate was 79.3%. The results revealed that the novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy was feasible, with adequate colon cleansing and completion rates, and has the potential to be used as an alternative regimen.
Lavender, Tina; Furber, Christine; Campbell, Malcolm; Victor, Suresh; Roberts, Ian; Bedwell, Carol; Cork, Michael J
2012-06-01
Some national guidelines recommend the use of water alone for napkin cleansing. Yet, there is a readiness, amongst many parents, to use baby wipes. Evidence from randomised controlled trials, of the effect of baby wipes on newborn skin integrity is lacking. We conducted a study to examine the hypothesis that the use of a specifically formulated cleansing wipe on the napkin area of newborn infants (<1 month) has an equivalent effect on skin hydration when compared with using cotton wool and water (usual care). A prospective, assessor-blinded, randomised controlled equivalence trial was conducted during 2010. Healthy, term babies (n=280), recruited within 48 hours of birth, were randomly assigned to have their napkin area cleansed with an alcohol-free baby wipe (140 babies) or cotton wool and water (140 babies). Primary outcome was change in hydration from within 48 hours of birth to 4 weeks post-birth. Secondary outcomes comprised changes in trans-epidermal water loss, skin surface pH and erythema, presence of microbial skin contaminants/irritants at 4 weeks and napkin dermatitis reported by midwife at 4 weeks and mother during the 4 weeks. Complete hydration data were obtained for 254 (90.7 %) babies. Wipes were shown to be equivalent to water and cotton wool in terms of skin hydration (intention-to-treat analysis: wipes 65.4 (SD 12.4) vs. water 63.5 (14.2), p=0.47, 95% CI -2.5 to 4.2; per protocol analysis: wipes 64.6 (12.4) vs. water 63.6 (14.3), p=0.53, 95% CI -2.4 to 4.2). No significant differences were found in the secondary outcomes, except for maternal-reported napkin dermatitis, which was higher in the water group (p=0.025 for complete responses). Baby wipes had an equivalent effect on skin hydration when compared with cotton wool and water. We found no evidence of any adverse effects of using these wipes. These findings offer reassurance to parents who choose to use baby wipes and to health professionals who support their use. Current Controlled Trials ISRCTN86207019.
Outward Peace, Inward Pieces: A Case of the Effect of the Kenya Post-Election Violence
ERIC Educational Resources Information Center
Ochieng', Josephine Atieno
2010-01-01
In December 2007, unprecedented violence erupted in Kenya following the announcement of disputed presidential election results. The electorate was divided along ethnic lines and tribal clashes bordering on ethnic cleansing escalated. Those supporting opposing camps found themselves on the wrong side of the political divide leading to killings,…
Use of topical haemoglobin on sloughy wounds in the community setting.
Bateman, Sharon Dawn
2015-09-01
This evaluation aimed to determine whether the use of a haemoglobin spray solution expedited sloughy wound healing. A descriptive evaluation was undertaken within a community setting exploring 25 patients presenting with sloughy healing and non-healing wounds, and the effects of 8 topically administered haemoglobin treatments over a 4-week period. Standard wound cleansing and dressing management were continued, with no changes to pre-evaluation regimens, and care being provided by the patients themselves or by a carer. Data were collected weekly with regard to primary outcomes of slough reduction, wound surface area reduction, patient ease of use (self-care), and overall product experience. At 4 weeks, all wounds demonstrated positive measured endpoints of slough elimination and continued wound-size reduction. Patients and carers found the product easy to use (self-caring) with an overall positive wound care experience. The administration of a haemoglobin spray solution on patients presenting with sloughy wounds resulted in positive healing outcomes of slough elimination and wound reduction alongside positive self-care and product satisfaction. Continued evaluation is recommended to build upon the evidence of this form of treatment.
Field performance of self-siphon sediment cleansing set for sediment removal in deep CSO chamber.
Zhou, Yongchao; Zhang, Yiping; Tang, Ping
2013-01-01
This paper presents a study of the self-siphon sediment cleansing set (SSCS), a system designed to remove sediment from the deep combined sewer overflow (CSO) chamber during dry-weather periods. In order to get a better understanding of the sediment removal effectiveness and operational conditions of the SSCS system, we carried out a full-scale field study and comparison analysis on the sediment depth changes in the deep CSO chambers under the conditions with and without the SSCS. The field investigation results demonstrated that the SSCS drains the dry-weather flow that accumulated for 50-57 min from the sewer channel to the intercepting system in about 10 min. It is estimated that the bed shear stress in the CSO chamber and sewer channel is improved almost 25 times on average. The SSCS acts to remove the near bed solids with high pollution load efficiently. Moreover, it cleans up not only the new sediment layer but also part of the previously accumulated sediment.
Diagnosis and treatment of demodectic blepharitis.
Inceboz, Tonay; Yaman, Aylin; Over, Leyla; Ozturk, Arif Taylan; Akisu, Ciler
2009-01-01
The aim of this study was to investigate the prevalence of Demodex spp. in the eyelash follicles obtained from patients seen in our ophthalmology clinic, to define the symptoms of this infestation, and to examine the effectivity of the therapy. This study was conducted in Department of Ophthalmology and Parasitology, Dokuz Eylül University, School of Medicine. Our study included 82 cases that were seen in the Ophthalmology Department and Parasitology Department for various reasons. We have also observed that the presence of Demodex spp. provokes itching and redness in the eyes and that using baby shampoo for cleansing the face reduces the risk of infestation. After the treatment of 32 cases with 4% pilocarpin HCl gel, we achieved a total cure in 12 eyes (37.5%), partial improvement in 13 eyes (40.6%), (making a total of 25 eyes, 78.1%). The treatment was unsuccessful in 7 eyes (21.9%). In patients with Demodex spp. cleansing with baby shampoo and treating by pilocarpin gel may be used in treatment.
Oliva, Salvatore; Cucchiara, Salvatore; Spada, Cristiano; Hassan, Cesare; Ferrari, Federica; Civitelli, Fortunata; Pagliaro, Giuseppe; Di Nardo, Giovanni
2014-01-01
Small bowel cleansing by capsule endoscopy has never been addressed in children. Randomized controlled trial to evaluate the effect of five bowel preparation regimens on the mucosal visibility surface (as percentage of visualized surface area). Group A: a clear liquid diet for 12 h on the day before; Group B: high volume polyethylene glycol (50 mL/kg, up to 2Lt/die); Group C: low volume polyethylene glycol (25 mL/kg up to 1Lt/die); Group D: 20 mL (376 mg) of oral simethicone; Group E: 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone. Overall, 198 patients (53% male, median age 13 years) were enrolled. Preparation regimen visualization scores were 14.1 ± 4.2, 18.9 ± 5.1, 17.8 ± 5.5, 14.9 ± 4.8 and 20.9 ± 4.6 in groups A, B, C, D and E, respectively (P < 0.01). Positive findings were found in 172 cases (87%), but no significant differences were observed in the diagnostic yield and tolerability. Interobserver agreement, k = 0.89 (95% CI 0.83 ± 0.71). This is the first report in children that supports the use of 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone as the preparation of choice for capsule endoscopy. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Neglected aspects in the management of acne.
Gordon, B
1985-01-01
Acne is the result of excessive grease on the skin. The successful treatment of acne depends essentially on the degreasing of the skin to an extent which produces peeling, which is the observable index of adequate treatment. The use of antibiotics is supplementary to degreasing and peeling. Degreasing is best achieved by thrice daily washing with Neutrogena acne cleansing soap, followed by the application of a benzoyl peroxide preparation of a suitable strength. If necessary, further degreasing can be achieved by cleansing with isopropyl alcohol after washing with the Neutrogena soap. PMID:2941579
DOE Office of Scientific and Technical Information (OSTI.GOV)
VANGELAS, KAREN
2005-05-19
Nature's inherent ability to cleanse itself is at the heart of Monitored Natural Attenuation (MNA). The complexity comes when one attempts to measure and calculate this inherent ability, called the Natural Attenuation Capacity (NAC), and determine if it is sufficient to cleanse the system to agreed upon criteria. An approach that is simple in concept for determining whether the NAC is sufficient for MNA to work is the concept of a mass balance. Mass balance is a robust framework upon which all decisions can be made. The inflows to and outflows from the system are balanced against the NAC ofmore » the subsurface system. For MNA to be acceptable, the NAC is balanced against the contaminant loading to the subsurface system with the resulting outflow from the system being in a range that is acceptable to the regulating and decision-making parties. When the system is such that the resulting outflow is not within an acceptable range, the idea of taking actions that are sustainable and that will bring the system within the acceptable range of outflows is evaluated. These sustainable enhancements are being developed under the Enhanced Attenuation (EA) concept.« less
Adams, K.A.; Vangelas, K.M.; Looney, B.B.; Chapelle, F.; Early, T.; Gilmore, T.; Sink, C.H.
2005-01-01
Nature's inherent ability to cleanse itself is at the heart of Monitored Natural Attenuation (MNA). The complexity comes when one attempts to measure and calculate this inherent ability, called the Natural Attenuation Capacity (NAC), and determine if it is sufficient to cleanse the system to agreed upon criteria. An approach that is simple in concept for determining whether the NAC is sufficient for MNA to work is the concept of a mass balance. Mass balance is a robust framework upon which all decisions can be made. The inflows to and outflows from the system are balanced against the NAC of the subsurface system. For MNA to be acceptable, the NAC is balanced against the contaminant loading to the subsurface system with the resulting outflow from the system being in a range that is acceptable to the regulating and decision-making parties. When the system is such that the resulting outflow is not within an acceptable range, the idea of taking actions that are sustainable and that will bring the system within the acceptable range of outflows is evaluated. These sustainable enhancements are being developed under the Enhanced Attenuation (EA) concept. Copyright ASCE 2005.
Instability in the Post-Cold War World: A Model for Evaluation and Decision Making
1993-04-15
countries. 1 3 In Bosnia-Herzegovina the Serbs, a mainly Christian culture, use their religion as a partial justification for their "ethnic cleansing" of the...Bosnians, a predominately Moslem culture. The clash of religions is also central to the battles between the Moslem Azeris and the Christian Armenians...Russians of the trans-Dnester region. 14 Even Buddhism, renowned as a religion of peace, figures in conflicts. The low level civil unrest in Tibet is
The Effectiveness of Hypochlorous Acid Solution on Healing of Infected Diabetic Foot Ulcers
ERIC Educational Resources Information Center
Ragab, Islam I.; Kamal, Ahmed
2017-01-01
Wound cleansing remains a corner stone in the management of diabetic foot ulcer. Hydrogen Peroxide (H[subscript 2]O[subscript 2]) and Povidone Iodine are topical antimicrobial agents but known to be toxic to cells involved in the wound healing cascade. The biggest challenge for the physicians and nurses is searching for a safe, noncytotoxic and…
Coal fly ash has several uses but much of the material is treated as waste and disposed of in various ways including land filling. Coal fly ash also has a very high sorption capacity for a variety of anthropogenic contaminants and has been used to cleanse wastewater of such poll...
Parente, Fabrizio; Vailati, Cristian; Bargiggia, Stefano; Manes, Gianpiero; Fontana, Paola; Masci, Enzo; Arena, Monica; Spinzi, Giancarlo; Baccarin, Alessandra; Mazzoleni, Giorgia; Testoni, Pier Alberto
2015-10-01
Chronic constipation is a risk factor of inadequate bowel preparation for colonoscopy; however, no large clinical trials have been performed in this subgroup of patients. To compare bowel cleansing efficacy, tolerability and acceptability of 2-L polyethylene-glycol-citrate-simethicone (PEG-CS) plus 2-day bisacodyl (reinforced regimen) vs. 4-L PEG in patients with chronic constipation undergoing colonoscopy. Randomized, observer-blind, parallel group study. Adult outpatients undergoing colonoscopy were randomly allocated to 2-L PEG-CS/bisacodyl or 4-L PEG, taken as split regimens before colonoscopy. Quality of bowel preparation was assessed by the Ottawa Bowel Cleansing Scale (OBCS). The amount of foam/bubble interfering with colonic visualization was also measured. 400 patients were enrolled. There was no significant difference in successful cleansing (OBCS score ≤6): 80.2% in the 2-L PEG-CS/bisacodyl vs. 81.4% in the 4-L PEG group. Significantly more patients taking 2L PEG-CS/bisacodyl showed no or minimal foam/bubbles in all colonic segments (80% vs. 63%; p<0.001). 2-L PEG-CS/bisacodyl was significantly more acceptable for ease of administration (p<0.001), willingness to repeat (p<0.001) and showed better compliance (p=0.002). Split 2-L PEG-CS plus bisacodyl was not superior to split 4-L PEG for colonoscopy bowel cleansing in patients with chronic constipation; however, it performed better than the standard regimen in terms of colonic mucosa visualization, patient acceptance and compliance. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Badia, Josep M; Arroyo-García, Nares
2018-05-14
The role of oral antibiotic prophylaxis and mechanical bowel preparation in colorectal surgery remains controversial. The lack of efficacy of mechanical preparation to improve infection rates, its adverse effects, and multimodal rehabilitation programs have led to a decline in its use. This review aims to evaluate current evidence on antegrade colonic cleansing combined with oral antibiotics for the prevention of surgical site infections. In experimental studies, oral antibiotics decrease the bacterial inoculum, both in the bowel lumen and surgical field. Clinical studies have shown a reduction in infection rates when oral antibiotic prophylaxis is combined with mechanical preparation. Oral antibiotics alone seem to be effective in reducing infection in observational studies, but their effect is inferior to the combined preparation. In conclusion, the combination of oral antibiotics and mechanical preparation should be considered the gold standard for the prophylaxis of postoperative infections in colorectal surgery. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Bowel preparation for colonoscopy: state of the art.
Voiosu, Theodor; Voiosu, Andrei; Voiosu, Radu
2016-07-13
Bowel preparation for colonoscopy is a key quality indicator that impacts on all aspects of the procedure, such as patient comfort, diagnostic yield, and adverse events. Although most laxative regimens currently employed have been compared in a multitude of settings, the optimal preparation regimen still remains an open question. Recent studies have focused on developing new regimens by modifying dosage, timing of administration or by combining laxatives with synergic mechanisms of action with the purpose of increasing patient tolerability while maximizing bowel cleansing. Several low-volume preparations and combinations of laxatives and adjunctive medication have shown promise in delivering both adequate preparation of the colon and good patient tolerability. Also, we have gained a better understanding of the influence of patient-related factors such as health literacy and education on the quality of bowel preparation. Although several novel regimens have been tested in recent trials, it remains unclear which, if any, of these bowel preparations can replace the standard bowel cleansing regimens in clinical practice. Also, further data are required on how to improve bowel cleansing by choosing the appropriate regimen for the individual patient.
Prototype wash water renovation system integration with government-furnished wash fixture
NASA Technical Reports Server (NTRS)
1984-01-01
The requirements of a significant quantity of proposed life sciences experiments in Shuttle payloads for available wash water to support cleansing operations has provided the incentive to develop a technique for wash water renovation. A prototype wash water waste renovation system which has the capability to process the waste water and return it to a state adequate for reuse in a typical cleansing fixture designed to support life science experiments was investigated. The resulting technology is to support other developments efforts pertaining to water reclamation by serving as a pretreatment step for subsequent reclamation procedures.
Chekmareva, I A
2002-02-01
Quantitative and structural functional analysis of granulation tissue cells during treatment with protein-polysaccharide dressing Collahit F was carried out. The preparation effectively cleansed the wound from detritus, prevented secondary infection due to stimulation of the functional activity of macrophages and due to the effect of its antiseptic component (furagin), and stimulated proliferative activity of fibroblasts and granulation tissue microvessels on day 5 of treatment, thus promoting repair processes in the wound.
1980-02-08
3. Shih, M.; Marshall, F. J.; and Rosen, S. The bactericidal efficiency of sodium hypochlorite as an endodontic irrigant. Oral Surg 29(4): 613-619...and Rosen9 investi- gated the cleansing effect of sodium hypochlorite and normal saline on the apical one third using a standard irrigating method. They...found that sodium hypochlorite was no better than normal saline solutiun in irrigating this segment. Salzgeber and Brilliant10 investigated the
Whole body cleaning agent containing N-acyltaurate
NASA Technical Reports Server (NTRS)
Lentsch, Steven E. (Inventor)
1992-01-01
The subject invention relates to a human cleansing agent particularly suitable for use in long duration spaceflight and to a method of bathing with the agent. The agent of the subject invention is in the form of a paste having a pH of 5.0 to 7.9 which comprises an acyltaurate, a skin conditioner, a hair conditioner, and a preservative. More specifically, it includes sodium N-coconut acid-N-methyl taurate, in combination with soybean lecithin, polyquaternium 16, and formalin. This particular combination satisfies the following objectives: (1) that it be usable with a minimum amount of water per shower (approximately 1 gallon); (2) that it be easily separated from the water for purposes of water reclamation; (3) that it be pH compatible with skin and hair; (4) that it rinse well in deionized water; (5) that it be mild to skin and eyes; (6) that it effectively clean both skin and hair; (7) that it be suitable for use in zero gravity; and (8) that it provide ease of combing of wet and dry hair. The method of the invention includes the steps of wetting the skin and hair with a small quantity of water, lathering the skin with the paste, rinsing the lather from the skin and hair with a small quantity of water to produce a rinse water containing the cleansing agent, defoaming the rinse water, and supplying the defoamed rinse water to a water reclamation unit for recycling the water. The novelty of the invention appears to lie in the particular formulation of the cleansing agent and its method of use which provide optimal results under the given constraints and objectives.
Tooth, David; Garsed, Klara; Singh, Gulzar; Marciani, Luca; Lam, Ching; Fordham, Imogen; Fields, Annie; Banwait, Rawinder; Lingaya, Melanie; Layfield, Robert; Hastings, Maggie; Whorwell, Peter; Spiller, Robin
2014-05-01
Faecal serine proteases (FSPs) may play a role in irritable bowel syndrome with diarrhoea (IBS-D), but their origin is unclear. We aimed to structurally characterise them and define the impact of colonic cleansing and transit time. Faecal samples were obtained from 30 healthy volunteers (HV) and 79 patients with IBS-D participating in a trial of ondansetron versus placebo. Colonic transit was measured using radio-opaque markers. Samples were also obtained from 24 HV before and after colonic cleansing with the osmotic laxative MoviPrep. FSPs were purified from faecal extracts using benzamidine-Sepharose affinity chromatography. SDS-PAGE profiled components were identified using trypsinolysis and tandem mass spectrometry. Functional protease activity in faecal extracts was measured using a colorimetric assay based on the proteolysis of azo-casein. Protein analysis identified the most abundant FSPs as being of human origin and probably derived from pancreatic juice. Functional assays showed increased faecal protease (FP) and amylase in patients with IBS-D compared with HV. Those with higher amylase had significantly higher FP and greater anxiety. FP activity correlated negatively with whole gut transit in patients with IBS-D (Spearman r=-0.32, p=0.005) and HV (r=-0.55, p=0.014). Colon cleansing caused a significant rise in FP activity in HV from a baseline of median (IQR) 253 (140-426) to 1031 (435-2296), levels similar to those seen in patients with IBS-D. FSP activity correlated positively with days/week with urgency. The most abundant FSPs are of human origin. Rapid transit through the colon and/or decreased (possibly bacterial) proteolytic degradation increases their faecal concentration and could contribute to visceral hypersensitivity in patients with IBS-D. NCT00745004.
A review of current issues underlying colon cleansing before colonoscopy
Hookey, Lawrence C; Vanner, Stephen
2007-01-01
The present review examines four current issues related to the efficacy, patient tolerance and safety of the following bowel cleansing agents: oral sodium phosphate (NaP), polyethylene glycol (PEG) and magnesium citrate (Pico-Salax, Ferring Pharmaceuticals Inc, Canada), an agent recently made available in Canada. MedLine and PubMed databases were systematically searched to identify studies related to the efficacy of altered PEG solutions combined with adjunct treatments; the efficacy, tolerability and safety of Pico-Salax; the association between nephrocalcinosis, and chronic renal failure and oral NaP use; and the role of diet. Although lower volume PEG solutions combined with adjuvant agents were generally associated with better patient tolerance, their efficacy was varied and interpretation of this end point is complicated by study design issues. There are very few reported studies of Pico-Salax, and as a result, there are insufficient data to draw conclusions about the efficacy of this agent. The available data suggest that Pico-Salax may be better tolerated by patients, than oral NaP and PEG solutions. There is a paucity of hemodynamic monitoring data pre- and postadministration, but the available data suggests that this small-volume osmotic agent could cause subclinical contraction of the intravascular space. Recent case reports suggest an association between nephrocalcinosis and oral NaP ingestion, but to date, these reports have been confined to a single centre. Preliminary studies suggest that this is not a widespread problem, but more studies are needed. There are only a few studies examining diet and patient tolerability, but they do suggest that diet may be liberalized with some cleansing regimens to enhance tolerability without decreasing efficacy. The present review highlights current controversies and advances in colon cleansing before colonoscopy, and also identifies areas for further study. PMID:17299615
Regan, Jamie; Mollica, Leonel-Maximo; Ananthapadmanabhan, K P
2013-06-01
To assess the properties of a novel body wash containing the mild surfactant glycinate. Biochemical and clinical assays. Research laboratories and clinical sites in the United States and Canada. Women 18 to 65 years of age (cleansing efficacy); male and female subjects 26 to 63 years of age with mild or moderate dryness and erythema (leg-controlled application test); subjects 5 to 65 years of age with mild-to-moderate eczema (eczema compatibility); and women 18 to 64 years of age (home use). Assessments across studies included colorimetric dye exclusion to assess skin damage potential (corneosurfametry), efficacy of cosmetic product removal from skin, change from baseline in visual dryness, change from baseline in Eczema Area and Severity Index, and self-perceived eczema attributes and self-reported product preference. The glycinate-based cleanser demonstrated mildness to skin components when evaluated in a corneosurfametry assay. Short-term use under exaggerated wash conditions in subjects with dryness scores <3 and erythema scores <2 (both on a 0-6 scale) indicated an initial reduction in visual dryness. In subjects with eczema, normal use resulted in significant improvements (p<0.05) at Week 4 compared with baseline in skin dryness (change from baseline = -0.73), rash (-0.56), itch (-0.927), tightness (-0.585), and all eczema (-0.756). The glycinate-based body wash removed 56 percent of a long-lasting cosmetic foundation from skin compared with less than 30 percent removed by two competitive products tested. The glycinate-based body wash was preferred over a competitive mild cleansing product overall. The patented glycinate-containing body wash demonstrated better product mildness and patient-preferred attributes and clinical benefits.
Rivas, John M; Perez, Alejandro; Hernandez, Marlow; Schneider, Alison; Castro, Fernando J
2014-01-01
AIM: To compare the bowel cleansing efficacy of same day ingestion of 4-L sulfa-free polyethylene glycol (4-L SF-PEG) vs 2-L polyethylene glycol solution with ascorbic acid (2-L PEG + Asc) in patients undergoing afternoon colonoscopy. METHODS: 206 patients (mean age 56.7 years, 61% male) undergoing outpatient screening or surveillance colonoscopies were prospectively randomized to receive either 4-L SF-PEG (n = 104) or 2-L PEG + Asc solution (n = 102). Colonoscopies were performed by two blinded endoscopists. Bowel preparation was graded using the Ottawa scale. Each participant completed a satisfaction and side effect survey. RESULTS: There was no difference in patient demographics amongst groups. 4-L SF-PEG resulted in better Ottawa scores compared to 2-L PEG + Asc, 4.2 vs 4.9 (P = 0.0186); left colon: 1.33 vs 1.57 respectively (P = 0.0224), right colon: 1.38 vs 1.63 respectively (P = 0.0097). No difference in Ottawa scores was found for the mid colon or amount of fluid. Patient satisfaction was similar for both arms but those assigned to 4-L SF-PEG reported less bloating: 23.1% vs 11.5% (P = 0.0235). Overall polyp detection, adenomatous polyp and advanced adenoma detection rates were similar between the two groups. CONCLUSION: Morning only 4-L SF-PEG provided superior cleansing with less bloating as compared to 2-L PEG + Asc bowel preparation for afternoon colonoscopy. Thus, future studies evaluating efficacy of morning only preparation for afternoon colonoscopy should use 4-L SF-PEG as the standard comparator. PMID:25132784
Terzaghi, G F; Settimi, L; Peverelli, C; Sevosi, L; Duca, P G
1996-01-01
The efficacy of 4 commercial cleansing products was tested with 3 colouring agents widely used in the dyeing industry in a randomised double blind trail involving 8 workers each time. A between-detergents statistically significant difference was observed; the interaction (detergents x colouring agents) was significant. The efficacy of type A detergent was higher for type I-III dyers, while the efficacy of type C detergent, which widely used was lowest.
Problem Reporting Taxonomy and Data Preparation Tool Evaluation
NASA Technical Reports Server (NTRS)
Beil, Robert J.
2010-01-01
A member of the NASA Engineering and Safety Center (NESC) Systems Engineering Office (SEO) Technical Discipline Team (TDT) requested a SEO-managed activity to perform a gap analysis on the proposed NASA Standard 0006, "Common NASA Taxonomy for Problem Reporting, Analysis, and Resolution", and to create an input filter and set of instructions for using the data-mining/data-cleansing tool TechOasis1 with Space Shuttle Program (SSP) problem reporting data. The work that achieved these objectives and deployment of TechOasis are discussed in this report.
Efficacy of dry-ice blasting in preventive maintenance of auto robotic assemblies
NASA Astrophysics Data System (ADS)
Baluch, Nazim; Mohtar, Shahimi; Abdullah, Che Sobry
2016-08-01
Welding robots are extensively applied in the automotive assemblies and `Spot Welding' is the most common welding application found in the auto stamping assembly manufacturing. Every manufacturing process is subject to variations - with resistance welding, these include; part fit up, part thickness variations, misaligned electrodes, variations in coating materials or thickness, sealers, weld force variations, shunting, machine tooling degradation; and slag and spatter damage. All welding gun tips undergo wear; an elemental part of the process. Though adaptive resistance welding control automatically compensates to keep production and quality up to the levels needed as gun tips undergo wear so that the welds remain reliable; the system cannot compensate for deterioration caused by the slag and spatter on the part holding fixtures, sensors, and gun tips. To cleanse welding robots of slag and spatter, dry-ice blasting has proven to be an effective remedy. This paper describes Spot welding process, analyses the slag and spatter formation during robotic welding of stamping assemblies, and concludes that the dry ice blasting process's utility in cleansing of welding robots in auto stamping plant operations is paramount and exigent.
Design, fabrication and acceptance testing of a zero gravity whole body shower, volume 1
NASA Technical Reports Server (NTRS)
1973-01-01
The effort to design whole body shower for the space station prototype is reported. Clothes and dish washer/dryer concepts were formulated with consideration given to integrating such a system with the overall shower design. Water recycling methods to effect vehicle weight savings were investigated and it was concluded that reusing wash and/or rinse water resulted in weight savings which were not sufficient to outweigh the added degree of hardware complexity. The formulation of preliminary and final designs for the shower are described. A detailed comparison of the air drag vs. vacuum pickup method was prepared that indicated the air drag concept results in more severe space station weight penalties; therefore, the preliminary system design was based on utilizing the vacuum pickup method. Tests were performed to determine the optimum methods of storing, heating and sterilizing the cleansing agent utilized in the shower; it was concluded that individual packages of pre-sterilized cleansing agent should be used. Integration features with the space station prototype system were defined and incorporated into the shower design as necessary.
Koussidis, G A; Koussidis, A
2001-12-01
To test the use of meglumine and sodium diatrizoate (Gastrografin) as an agent for preoperative mechanical bowel preparation. Prospective randomised comparison. County general hospital, Greece. 58 patients listed for elective colorectal operations were randomly divided into 2 groups. The first (n = 30) was given Gastrografin 200 ml orally for 2 consecutive days before operation, and the second (n = 28) was given Ringer's solution through a nasogastric tube. Tolerability, acceptability, quality of cleansing, and complications. There were no disturbances in electrolyte concentrations, and other laboratory variables also remained unchanged. Two patients treated with Ringer's solution had appreciable increases in arterial blood pressure, but there were no significant overall changes. About half the patients given Ringer's felt nauseated and a third vomited. Such symptoms were uncommon in patients treated with Gastrografin (p < 0.01). 28/30 and 26/28 (93%) had a clean colonic lumen at operation, whereas in the reminder the lumen was evaluated as containing "slight residue". There were no operation-related complications. Gastrografin can be used successfully as an agent for mechanical bowel preparation before elective colorectal surgery, as it gives equally good cleansing results compared with the established method of whole gut irrigation. It also seems to be better tolerated and accepted by patients.
Conservation of water for washing beef heads at harvest.
DeOtte, R E; Spivey, K S; Galloway, H O; Lawrence, T E
2010-03-01
The objective of this research was to develop methods to conserve water necessary to cleanse beef heads prior to USDA-FSIS inspection. This was to be accomplished by establishing a baseline for the minimum amount of water necessary to adequately wash a head and application of image analysis to provide an objective measure of head cleaning. Twenty-one beef heads were manually washed during the harvest process. An average 18.75 L (2.49 SD) and a maximum of 23.88 L were required to cleanse the heads to USDA-FSIS standards. Digital images were captured before and after manual washing then evaluated for percentage red saturation using commercially available image analysis software. A decaying exponential curve extracted from these data indicated that as wash water increased beyond 20 L the impact on red saturation decreased. At 4 sigma from the mean of 18.75 L, red saturation is 16.0 percent, at which logistic regression analysis indicates 99.994 percent of heads would be accepted for inspection, or less than 1 head in 15,000 would be rejected. Reducing to 3 sigma would increase red saturation to 27.6 percent, for which 99.730 percent of heads likely would be accepted (less than 1 in 370 would be rejected). Copyright 2009 Elsevier Ltd. All rights reserved.
Becker, D F; Weine, S M; Vojvoda, D; McGlashan, T H
1999-06-01
The authors describe the psychiatric sequelae of "ethnic cleansing" in adolescent Bosnian refugees, via a 1-year follow-up study. Ten Bosnian adolescent refugees from the war in Bosnia-Herzegovina received a baseline assessment within the first year after their resettlement and a follow-up assessment 1 year later. Evaluations included an assessment scale for posttraumatic stress disorder (PTSD) symptom severity. At baseline, 3 subjects met criteria for PTSD. At follow-up, this diagnosis persisted in none of these subjects, though 1 subject met criteria at follow-up only. For the group, mean PTSD severity scores at baseline and at follow-up were 8.9 and 4.0, respectively. At baseline, reexperiencing symptoms were present 43% of the time, avoidance symptoms were present 33% of the time, and hyperarousal symptoms were present 33% of the time; at follow-up, these proportions were 35%, 16%, and 18%, respectively. Overall, rates of PTSD symptoms diminished during the 1-year follow-up interval, suggesting that they may be transient and not representative of enduring psychopathology. This finding may reflect the relative resiliency of adolescents, as well as a variety of factors that facilitated adaptation in our particular group of adolescent refugees.
Does modifying personal responsibility moderate the mental contamination effect?
Kennedy, Tinisha S; Simonds, Laura M
2017-12-01
Mental contamination is the psychological sense of internal dirtiness that arises in the absence of physical contact with a perceived contaminant. Mental contamination can be evoked through imagining perpetrating a moral transgression. This study experimentally evoked mental contamination by asking men to imagine perpetrating a non-consensual kiss. It explored whether reducing sense of personal responsibility for the kiss moderated the mental contamination effect. Male students (N = 60) imagined giving either a consensual or non-consensual kiss. Personal responsibility for the kiss was manipulated in one of two non-consensual kiss conditions by way of the inclusion of social influence information. Feelings of mental contamination were assessed by self-report and through a behavioural index. Mental contamination was successfully induced in the two non-consensual kiss conditions. There was evidence to support the hypothesis that reducing personal responsibility might moderate specific components of mental contamination (shame, dirtiness and urge to cleanse). The effect of responsibility modification was evident in the self-report measures, but not in the behavioural index. The sample comprised male university students which limits generalizability of the findings. The behavioural assessment of mental contamination was limited to a proxy measure. Imagined moral violations are associated with increases in indices of mental contamination. Further research should investigate whether feelings of shame, dirtiness and urge to cleanse are particularly responsive to responsibility modifications. Copyright © 2017 Elsevier Ltd. All rights reserved.
Translations on Environmental Quality, Number 127
1976-12-29
first cleansing is done "by the highly effective method of electrocoagulation . It is "based on the passage of a constant electric flow with a voltage of...chemical rea- gents and becomes suitable for repeated use in industry. With the aid of iod- exchange devices electrocoagulation is supplemented with... electrocoagulation method, it is creating unified devices for the various substances contained in water and is improving plant design. All this will guarantee
Jeyapalan, Karthigeyan; Kumar, Jaya Krishna; Azhagarasan, N S
2015-08-01
The aim was to evaluate and compare the effects of three chemically different commercially available denture cleansing agents on the surface topography of two different denture base materials. Three chemically different denture cleansers (sodium perborate, 1% sodium hypochlorite, 0.2% chlorhexidine gluconate) were used on two denture base materials (acrylic resin and chrome cobalt alloy) and the changes were evaluated at 3 times intervals (56 h, 120 h, 240 h). Changes from baseline for surface roughness were recorded using a surface profilometer and standard error of the mean (SEM) both quantitatively and qualitatively, respectively. Qualitative surface analyses for all groups were done by SEM. The values obtained were analyzed statistically using one-way ANOVA and paired t-test. All three denture cleanser solutions showed no statistically significant surface changes on the acrylic resin portions at 56 h, 120 h, and 240 h of immersion. However, on the alloy portion changes were significant at the end of 120 h and 240 h. Of the three denture cleansers used in the study, none produced significant changes on the two denture base materials for the short duration of immersion, whereas changes were seen as the immersion periods were increased.
Jeyapalan, Karthigeyan; Kumar, Jaya Krishna; Azhagarasan, N. S.
2015-01-01
Aims: The aim was to evaluate and compare the effects of three chemically different commercially available denture cleansing agents on the surface topography of two different denture base materials. Materials and Methods: Three chemically different denture cleansers (sodium perborate, 1% sodium hypochlorite, 0.2% chlorhexidine gluconate) were used on two denture base materials (acrylic resin and chrome cobalt alloy) and the changes were evaluated at 3 times intervals (56 h, 120 h, 240 h). Changes from baseline for surface roughness were recorded using a surface profilometer and standard error of the mean (SEM) both quantitatively and qualitatively, respectively. Qualitative surface analyses for all groups were done by SEM. Statistical Analysis Used: The values obtained were analyzed statistically using one-way ANOVA and paired t-test. Results: All three denture cleanser solutions showed no statistically significant surface changes on the acrylic resin portions at 56 h, 120 h, and 240 h of immersion. However, on the alloy portion changes were significant at the end of 120 h and 240 h. Conclusion: Of the three denture cleansers used in the study, none produced significant changes on the two denture base materials for the short duration of immersion, whereas changes were seen as the immersion periods were increased. PMID:26538915
Andrucioli, Marcela Cristina Damião; de Macedo, Leandro Dorigan; Panzeri, Heitor; Lara, Elza Helena Guimarães; Paranhos, Helena de Freitas Oliveira
2004-01-01
The efficacy of 2 oral hygiene products, an experimental toothpaste specific for complete denture cleansing and a regular standard toothpaste, was compared in terms of denture biofilm removal and cure of palatal lesions in patients with atrophic chronic candidiasis. The degree of correlation between presence of biofilm and mucosa erythema was also evaluated. Twenty-four complete denture wearers (45-80 years old) were divided into 2 groups: experimental paste and standard toothpaste (Sorriso-Kolynos, Brazil). Both groups received soft toothbrushes. The internal surfaces of upper dentures were stained using 1% sodium fluorescein and photographed at a 45 masculine angle at 0, 15, 30 and 60 days. The slides were scanned and the areas of interest (denture total area and biofilm area) were measured (Image Tool software). The degree of erythema was evaluated on slides according to the Prosthesis Tissue Index. There was a significant reduction (1%) in the degree of biofilm (ANOVA/Tukey) between the two initial visits (0 and 15 days) and the two final visits (30 and 60 days), and in the average erythema scores (Kruskal-Wallis) between 0 and 60 days, in both groups. The Mann-Whitney test showed a significant difference (1%) between pastes in terms of biofilm degree, but no difference was found for the erythema score. Correlation values between biofilm and erythema degree were 0.3801 (experimental paste) and (0.3678 (standard toothpaste). We may therefore conclude that the experimental product was efficient for the removal of denture plaque biofilm.
Zhang, Hongfeng; Henry, Winoah A; Chen, Lea Ann; Khashab, Mouen A
2015-01-01
Both jejunal nodular lymphoid hyperplasia (NLH) and polyethylene glycol (PEG)-3350 hypersensitivity are extremely rare. We describe a 30-year-old female who had previously taken a PEG-3350 bowel preparation without adverse effects, and presented for evaluation of chronic diarrhea. An upper and lower gastrointestinal endoscopy, and small bowel series were scheduled. PEG-3350 and electrolytes for oral solution was prescribed for bowel cleansing. During consumption of the bowel preparation she developed urticarial hypersensitivity. An alternative bowel preparation was used. Colonoscopy and upper endoscopy were normal, but small bowel series revealed innumerable sand-like lucencies in the jejunum. NLH was confirmed on biopsy from antegrade enteroscopy. This is the first case report on the pathological jejunal NLH in association with the PEG-3350 urticarial hypersensitivity. The potential pathophysiological etiology of this association is discussed.
Zhang, Hongfeng; Henry, Winoah A.; Chen, Lea Ann; Khashab, Mouen A.
2015-01-01
Both jejunal nodular lymphoid hyperplasia (NLH) and polyethylene glycol (PEG)-3350 hypersensitivity are extremely rare. We describe a 30-year-old female who had previously taken a PEG-3350 bowel preparation without adverse effects, and presented for evaluation of chronic diarrhea. An upper and lower gastrointestinal endoscopy, and small bowel series were scheduled. PEG-3350 and electrolytes for oral solution was prescribed for bowel cleansing. During consumption of the bowel preparation she developed urticarial hypersensitivity. An alternative bowel preparation was used. Colonoscopy and upper endoscopy were normal, but small bowel series revealed innumerable sand-like lucencies in the jejunum. NLH was confirmed on biopsy from antegrade enteroscopy. This is the first case report on the pathological jejunal NLH in association with the PEG-3350 urticarial hypersensitivity. The potential pathophysiological etiology of this association is discussed. PMID:25608714
Winker, Robert; Salameh, Bayda; Stolkovich, Sabine; Nikl, Michael; Barth, Alfred; Ponocny, Elisabeth; Drexler, Hans; Tappeiner, Gerhard
2009-04-01
The aim of the trial was to investigate whether the publicized effects of skin protection creams can be replicated in a real occupational setting during activities that expose the skin. A prospective, randomized, four-tailed controlled pilot trial was performed to compare the effect of skin protection and skin care alone or in combination with cleansing against a control group (only cleansing). Two branches were selected for the investigation: the building industry and the timber industry. A total of 1,006 workers from these two branches were recruited, and out of these 485 workers were examined longitudinally for at least three time points over 1 year (lost for follow-up: 430 workers, exclusion: 91 workers). At each time point, as a primary outcome measure, we assessed the condition of the skin at both hands in a blinded manner and the individual was assigned to one of the following categories: no eczema, mild, moderate and severe eczema. As a secondary outcome measure, the worker's transepidermal water loss (TEWL) was measured under standardized conditions at the back of both hands. In addition, the workers were asked to evaluate their skin condition during the study. With regard to differences in the occurrence of eczemas, we found only in workers in building industry without application of skin protection or skin care creams a statistical significant increase in the incidence between the first and the second visit and a statistical significant decrease in the incidence between the second and third visit. When evaluating the secondary outcome-measurement changes in the TEWL values, an improvement was found for the group skin protection and skin care in combination and by skin care alone. Females in the timber industry started with better TEWL values than males, which may be due to better overall skin care. In this group we found an improvement for the group skin protection and skin care in combination and by skin protection alone. For skin protection alone, we noted a slight, but not significant improvement in all other groups. The subjective improvement of skin condition was reported from the participants who used skin protection and skin care in combination. Taking all these secondary-outcome measurements together, the main result of this study was that skin protection creams alone have a small effect on the skin barrier in workers in the building and timber industries compared with skin care alone or in combination with skin protection.
Gulalp, Betul; Seyhan, Tamer; Gursoy, Sonnur; Altinors, M Nur
2009-01-01
Background Ethyl-2-cyanoacrylate (ECA) is a tissue adhesive material applied to close superficial wounds. The aim of this study was to explore the benefits of cyanoacrylates in the emergency department in children with current application with regard to cost-effectiveness, satisfaction and long follow up. Findings Patients were treated after assignment of the consent with an explanation by the relatives in a tertiary emergency department (ED), 2007. The evaluation was based on different superficial wound repairs due to blunt trauma within a 2-hour time period (<6 hours), and small wounds (≤3 cm). These wounds were cleansed with serum sale and then dried with gauze. Wound repairs were observed for six months in order to observe the tissue changes. The patient's age, sex, indication, application time, pain score, cost, additional tending (if needed), complications, and cosmetic satisfaction were recorded. A total of 9 patients were evaluated and followed for 6 months. Except for one, all children were treated without any serious complications. ECA was cost-effective, time-saving, and provided successful repair satisfaction by a blinded plastic surgeon and patient/parents. Conclusion This report displayed the pediatric effective use of cyanoacrylates, even in non- traditional repairs in the emergency departments. PMID:19594954
[Preparation for colonoscopy: types of scales and cleaning products].
Lorenzo-Zúñiga, Vicente; Moreno-de-Vega, Vicente; Boix, Jaume
2012-08-01
Adequate bowel preparation is essential before a colonoscopy, allowing us to make a proper examination of the entire mucosa. The ideal method of colon cleansing should be fast, safe, and get a proper cleaning with minimal discomfort for the patient. Today we have a wide variety of colon cleansing products, information sometimes becomes confused. A good colon preparation depends partly on correct choice of the same, but also upon dietary restriction. Knowledge of all these products, with their advantages and limitations, we can make a better selection for each patient, and although the efficacy is comparable, is the experience of the browser, patient preferences, and the degree of compliance with the instructions preparation, which greatly influence the results.
Blanch Resistant and Thermal Barrier NiAl Coating Systems for Advanced Copper Alloys
NASA Technical Reports Server (NTRS)
Raj, Sai V. (Inventor)
2005-01-01
A method of forming an environmental resistant thermal barrier coating on a copper alloy is disclosed. The steps include cleansing a surface of a copper alloy, depositing a bond coat on the cleansed surface of the copper alloy, depositing a NiAl top coat on the bond coat and consolidating the bond coat and the NiAl top coat to form the thermal barrier coating. The bond coat may be a nickel layer or a layer composed of at least one of copper and chromium-copper alloy and either the bond coat or the NiAl top coat or both may be deposited using a low pressure or vacuum plasma spray.
Weine, S M; Becker, D F; Vojvoda, D; Hodzic, E; Sawyer, M; Hyman, L; Laub, D; McGlashan, T H
1998-01-01
The authors used the SCID-DES (disorders of extreme stress) instrument to assess for personality change in Bosnian survivors of "ethnic cleansing." Twenty four refugees underwent systematic, trauma-focused, research assessments, including the SCID-DES interview. Overall, this group of Bosnian survivors had been severely traumatized as a result of the Serbian nationalists' genocide. However, no subject met diagnostic criteria for DES. The SCID-DES yields far lower rates of trauma-related personality change in Bosnian survivors of genocide than in adult survivors of prolonged early life traumas. Therefore, the DES construct may have better application to prolonged, interpersonal, early life traumas than to the prolonged, communal traumas of genocide.
Del Rosso, James Q
2013-06-01
This article reviews background on proteases and their functions, their physiological significance in skin, and the potential implications of incorporating specific proteases and protease blends into dermatological products, including skin care formulations. The history of protease blend formulations used in wound model studies and for other disorders is reviewed. In vitro data with use of a specific 3-protease blend with evaluation of the impact on various skin proteins and peptides is also discussed in this article.
Colon Cleansing: Health or Hype?
... Clinical Trials Cancer Genomics Laboratory Cancer Prevention and ... Shot is revolutionizing the conventional medical research approach to rapidly translate findings into patient treatment options ...
NASA Technical Reports Server (NTRS)
Vernier, J. P.; Pommereau, J. P.; Thomason, L. W.; Pelon, J.; Garnier, A.; Deshler, T.; Jumelet, J.; Nielsen, J. K.
2011-01-01
The evolution of aerosols in the tropical upper troposphere/lower stratosphere between June 2006 and October 2009 is examined using the observations of the space borne CALIOP lidar aboard the CALIPSO satellite. Superimposed on several volcanic plumes and soot from an extreme biomass-burning event in 2009, the measurements reveal the existence of fast cleansing episodes of the lower stratosphere to altitudes as high as 20 km. The cleansing of the full 14-20km layer takes place within 1-4 months. Its coincidence with the maximum of convective activity in the southern tropics, suggests that the cleansing is the result of a large number of overshooting towers, injecting aerosol-poor tropospheric air into the lower stratosphere. The enhancements of aerosols at the tropopause level during the NH summer may be due to the same transport process but associated with intense sources of aerosols at the surface. Since, the tropospheric air flux derived from CALIOP observations during North Hemisphere winter is 5 20 times larger than the slow ascent by radiative heating usually assumed, the observations suggest that convective overshooting is a major contributor to troposphere-to-stratosphere transport with concommitant implications to the Tropical Tropopause Layer top height, chemistry and thermal structure.
Mullany, Luke C; El Arifeen, Shams; Winch, Peter J; Shah, Rasheduzzaman; Mannan, Ishtiaq; Rahman, Syed M; Rahman, Mohammad R; Darmstadt, Gary L; Ahmed, Saifuddin; Santosham, Mathuram; Black, Robert E; Baqui, Abdullah H
2009-10-21
The World Health Organization recommends dry cord care for newborns but this recommendation may not be optimal in low resource settings where most births take place in an unclean environment and infections account for up to half of neonatal deaths. A previous trial in Nepal indicated that umbilical cord cleansing with 4.0% chlorhexidine could substantially reduce mortality and omphalitis risk, but policy changes await additional community-based data. The Projahnmo Chlorhexidine study was a three-year, cluster-randomized, community-based trial to assess the impact of three cord care regimens on neonatal mortality and omphalitis. Women were recruited mid-pregnancy, received a basic package of maternal and neonatal health promotion messages, and were followed to pregnancy outcome. Newborns were visited at home by local village-based workers whose areas were randomized to either 1) single- or 2) 7-day cord cleansing with 4.0% chlorhexidine, or 3) promotion of dry cord care as recommended by WHO. All mothers received basic messages regarding hand-washing, clean cord cutting, and avoidance of harmful home-base applications to the cord. Death within 28 days and omphalitis were the primary outcomes; these were monitored directly through home visits by community health workers on days 1, 3, 6, 9, 15, and 28 after birth. Due to report in early 2010, the Projahnmo Chlorhexidine Study examines the impact of multiple or single chlorhexidine cleansing of the cord on neonatal mortality and omphalitis among newborns of rural Sylhet District, Bangladesh. The results of this trial will be interpreted in conjunction with a similarly designed trial previously conducted in Nepal, and will have implications for policy guidelines for optimal cord care of newborns in low resource settings in Asia. ClinicalTrials.gov (NCT00434408).
Minella, Marco; De Laurentiis, Elisa; Buhvestova, Olga; Haldna, Marina; Kangur, Külli; Maurino, Valter; Minero, Claudio; Vione, Davide
2013-03-01
Over the last 3-4 decades, Lake Peipsi water (sampling site A, middle part of the lake, and site B, northern part) has experienced a statistically significant increase of bicarbonate, pH, chemical oxygen demand, nitrate (and nitrite in site B), due to combination of climate change and eutrophication. By photochemical modelling, we predicted a statistically significant decrease of radicals ·OH and CO3(-·) (site A, by 45% and 35%, respectively) and an increase of triplet states of chromophoric dissolved organic matter ((3)CDOM(∗); site B, by ∼25%). These species are involved in pollutant degradation, but formation of harmful by-products is more likely with (3)CDOM(∗) than with ·OH. Therefore, the photochemical self-cleansing ability of Lake Peipsi probably decreased with time, due to combined effects of climate change and eutrophication. In different environments (e.g. Lake Maggiore, NW Italy), ecosystem restoration policies had the additional advantage of enhancing sunlight-driven detoxification, suggesting that photochemical self-cleansing would be positively correlated with lake water quality. Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farrar, Charles; Park, Gyuhae; Farinholt, Kevin
2010-12-08
This seminar will provide an overview of structural health monitoring (SHM) research that is being undertaken at Los Alamos National Laboratory (LANL). The seminar will begin by stating that SHM should be viewed as an important component of the more comprehensive intelligent life-cycle engineering process. Then LANL's statistical pattern recognition paradigm for addressing SHM problems will be introduced and current research that is focused on each part of the paradigm will be discussed. In th is paradigm, the process can be broken down into four parts: (1) Operational Evaluation, (2) Data Acquisition and Cleansing, (3) Feature Extraction, and (4) Statisticalmore » Model Development for Feature Discrimination. When one attempts to apply this paradigm to data from real world structures, it quickly becomes apparent that the ability to cleanse, compress, normalize and fuse data to account for operational and environmental variability is a key implementation issue when addressing Parts 2-4 of this paradigm. This discussion will be followed by the introduction a new project entitled 'Intelligent Wind Turbines' which is the focus of much of our current SHM research . This summary will be followed by a discussion of issues that must be addressed if this technology is to make the transition from research to practice and new research directions that are emerging for SHM.« less
Multicenter, randomized study to optimize bowel preparation for colon capsule endoscopy
Kastenberg, David; Jr, Wilmot C Burch; Romeo, David P; Kashyap, Pankaj K; Pound, David C; Papageorgiou, Neophytos; Sainz, Ignacio Fernández-Urien; Sokach, Carly E; Rex, Douglas K
2017-01-01
AIM To assess the cleansing efficacy and safety of a new Colon capsule endoscopy (CCE) bowel preparation regimen. METHODS This was a multicenter, prospective, randomized, controlled study comparing two CCE regimens. Subjects were asymptomatic and average risk for colorectal cancer. The second generation CCE system (PillCam® COLON 2; Medtronic, Yoqneam, Israel) was utilized. Preparation regimens differed in the 1st and 2nd boosts with the Study regimen using oral sulfate solution (89 mL) with diatrizoate meglumine and diatrizoate sodium solution (“diatrizoate solution”) (boost 1 = 60 mL, boost 2 = 30 mL) and the Control regimen oral sulfate solution (89 mL) alone. The primary outcome was overall and segmental colon cleansing. Secondary outcomes included safety, polyp detection, colonic transit, CCE completion and capsule excretion ≤ 12 h. RESULTS Both regimens had similar cleansing efficacy for the whole colon (Adequate: Study = 75.9%, Control = 77.3%; P = 0.88) and individual segments. In the Study group, CCE completion was superior (Study = 90.9%, Control = 76.9%; P = 0.048) and colonic transit was more often < 40 min (Study = 21.8%, Control = 4%; P = 0.0073). More Study regimen subjects experienced adverse events (Study = 19.4%, Control = 3.4%; P = 0.0061), and this difference did not appear related to diatrizoate solution. Adverse events were primarily gastrointestinal in nature and no serious adverse events related either to the bowel preparation regimen or the capsule were observed. There was a trend toward higher polyp detection with the Study regimen, but this did not achieve statistical significance for any size category. Mean transit time through the entire gastrointestinal tract, from ingestion to excretion, was shorter with the Study regimen while mean colonic transit times were similar for both study groups. CONCLUSION A CCE bowel preparation regimen using oral sulfate solution and diatrizoate solution as a boost agent is effective, safe, and achieved superior CCE completion. PMID:29358870
How to promote and preserve eyelid health.
Benitez-Del-Castillo, Jose M
2012-01-01
Disorders of the lacrimal functional unit are common in ophthalmological practice, with meibomian gland dysfunction, blepharitis, and dry eye forming a significant part of the general ophthalmologist's practice. The eyelid and its associated structures form a complex organ designed to protect the fragile corneal surface and improve visual acuity. This organ is subject to a number of disorders, including meibomian gland dysfunction, dry eye syndrome, anterior blepharitis, allergic and dermatological conditions, and disorders associated with contact lens use. Although commonly described separately, disorders of the lacrimal function unit are better considered as a group of interacting pathologies that have inflammatory mediators as a central feature. Eyelid hygiene, in the sense of routine cleansing and massage of the eyelids, is well accepted in the management of many disorders of the eyelid. However, a broader concept of eyelid health may be appropriate, in which eyelid cleansing is but a part of a more complete program of care that includes screening and risk assessment, patient education, and coaching. The ophthalmologist has an important role to play in helping patients persist with routine eyelid care that may be long-term or lifelong. A number of preparations exist to make routine eyelid care both more effective and more pleasant, and might also improve compliance. Several such preparations have been devised, and are being assessed in clinical studies, and appear to be effective and preferred by patients over traditional soap and water or baby shampoo.
Chacaltana Mendoza, Alfonso; Rodríguez Ulloa, Carlos
2008-01-01
In search alternatives for colonoscopic preparation, we decided to compare the effectiveness, safety and tolerance of the use of 10% manitol with polyethyleneglycol. A prospective, randomized and simple blind study was performed. Eighty consecutive inpatients were prospectively randomized to receive bowel preparation for elective colonoscopy with either 1 liter of 10% manitol (M Group, n=40) or 4 liters of polyethyleneglycol (PEG Group, n=40). Criteria of evaluation were quality of preparation, pre and post preparation laboratory seric test (sodium, potassium, osmolarity) and the presence of undesirable side effects during the preparation. Both groups were comparable in age, sex and colonoscopic indications. There was no difference between both groups when evaluating the quality of preparation: good or excellent preparation of 87.5% (manitol Group) and 90% (PEG Group) (p=0.37). The frequency of adverse effects was minor in group manitol (30%) that in group PEG (42.5%), being the nausea the most frequent symptom in both groups. A slight increase in the levels of sodium, potassium and osmolarity serums was found in both groups, without statistical difference or clinical repercussion. The preparation for colon cleansing with 10% manitol is as effective and safe, but better tolerated and accepted than preparation with PEG. 10% manitol would be a good alternative for colonoscopic preparation, specially for diagnostic procedures.
McClure, Elizabeth M; Goldenberg, Robert L; Brandes, Neal; Darmstadt, Gary L; Wright, Linda L
2009-01-01
Of the 4 million neonatal deaths and 500,000 maternal deaths that occur annually worldwide, almost 99% are in developing countries and one-third are associated with infections. Implementation of proven interventions and targeted research on a select number of promising high-impact preventative and curative interventions are essential to achieve Millennium Development Goals for reduction of child and maternal mortality. Feasible, simple, low-cost interventions have the potential to significantly reduce the mortality and severe morbidity associated with infection in these settings. Studies of chlorhexidine in developing countries have focused on three primary uses: 1) intrapartum vaginal and neonatal wiping, 2) neonatal wiping alone, and 3) umbilical cord cleansing. A study of vaginal wiping and neonatal skin cleansing with chlorhexidine, conducted in Malawi in the 1990s suggested that chlorhexidine has potential to reduce neonatal infectious morbidity and mortality. A recent trial of cord cleansing conducted in Nepal also demonstrated benefit. Although studies have shown promise, widespread acceptance and implementation of chlorhexidine use has not yet occurred. This paper is derived in part from data presented at a conference on the use of chlorhexidine in developing countries and reviews the available evidence related to chlorhexidine use to reduce mortality and severe morbidity due to infections in mothers and neonates in low-resource settings. It also summarizes issues related to programmatic implementation. PMID:17399714
Medical Approach to the Management of Traumatized Refugees.
Kinzie, J David
2016-03-01
Refugees are a highly traumatized and culturally diverse group of patients who present many clinical challenges. Refugees have a high prevalence of traumas from torture, ethnic cleansing, and the effects of long civil wars. The most common diagnoses associated with the effects of such traumas are posttraumatic stress disorder (PTSD) or PTSD with comorbid depression; however, psychosis and neurocognitive disorders are also common. For those with PTSD, a suggested treatment approach is long-term supportive psychotherapy with drug treatment directed at reducing the most disruptive symptoms, such as insomnia, nightmares, and irritability or psychosis. The author recommends a sedative tricyclic antidepressant, clonidine or prazosin, and aripiprazole as a useful combination of medications to provide rapid relief. In addition to PTSD, long-term studies indicate a high prevalence of diabetes and hypertension in traumatized refugees. It is therefore important to perform a thorough evaluation for these disorders that includes the measurement of blood pressure and a blood test for diabetes. When managed with such a medical approach, refugees are generally accepting of psychiatric treatment and can obtain relief from the symptoms associated with the massive trauma and losses they have experienced.
Balanced-Rotating-Spray Tank-And-Pipe-Cleaning System
NASA Technical Reports Server (NTRS)
Thaxton, Eric A.; Caimi, Raoul E. B.
1995-01-01
Spray head translates and rotates to clean entire inner surface of tank or pipe. Cleansing effected by three laterally balanced gas/liquid jets from spray head that rotates about longitudinal axis. Uses much less liquid. Cleaning process in system relies on mechanical action of jets instead of contaminant dissolution. Eliminates very difficult machining needed to make multiple converging/diverging nozzles within one spray head. Makes nozzle much smaller. Basic two-phase-flow, supersonic-nozzle design applied to other spray systems for interior or exterior cleaning.
Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy
Pontone, Stefano; Angelini, Rita; Standoli, Monica; Patrizi, Gregorio; Culasso, Franco; Pontone, Paolo; Redler, Adriano
2011-01-01
AIM: To investigate the effectiveness of low-volume plus ascorbic acid [polyethylene glycol plus ascorbic acid (PEG + Asc)] and high-volume plus simethicone [polyethylene glycol plus simethicone (PEG + Sim)] bowel preparations. METHODS: A total of one hundred and forty-four outpatients (76 males), aged from 20 to 84 years (median age 59.5 years), who attended our Department, were divided into two groups, age and sex matched, and underwent colonoscopy. Two questionnaires, one for patients reporting acceptability and the other for endoscopists evaluating bowel cleansing effectiveness according to validated scales, were completed. Indications, timing of examination and endoscopical findings were recorded. Biopsy forceps were used as a measuring tool in order to determine polyp endoscopic size estimation. Difficulty in completing the preparation was rated in a 5-point Likert scale (1 = easy to 5 = unable). Adverse experiences (fullness, cramps, nausea, vomiting, abdominal pain, headache and insomnia), number of evacuations and types of activities performed during preparation (walking or resting in bed) were also investigated. RESULTS: Seventy-two patients were selected for each group. The two groups were age and sex matched as well as being comparable in terms of medical history and drug therapies taken. Fourteen patients dropped out from the trial because they did not complete the preparation procedure. Ratings of global bowel cleansing examinations were considered to be adequate in 91% of PEG + Asc and 88% of PEG + Sim patients. Residual Stool Score indicated similar levels of amount and consistency of residual stool; there was a significant difference in the percentage of bowel wall visualization in favour of PEG + Sim patients. In the PEG + Sim group, 12 adenomas ≤ 10 mm diameter (5/left colon + 7/right colon) vs 9 (8/left colon + 1/right colon) in the PEG + Asc group were diagnosed. Visualization of small lesions seems to be one of the primary advantages of the PEG + Sim preparation. CONCLUSION: PEG + Asc is a good alternative solution as a bowel preparation but more improvements are necessary in order to achieve the target of a perfect preparation. PMID:22180711
Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy.
Pontone, Stefano; Angelini, Rita; Standoli, Monica; Patrizi, Gregorio; Culasso, Franco; Pontone, Paolo; Redler, Adriano
2011-11-14
To investigate the effectiveness of low-volume plus ascorbic acid [polyethylene glycol plus ascorbic acid (PEG + Asc)] and high-volume plus simethicone [polyethylene glycol plus simethicone (PEG + Sim)] bowel preparations. A total of one hundred and forty-four outpatients (76 males), aged from 20 to 84 years (median age 59.5 years), who attended our Department, were divided into two groups, age and sex matched, and underwent colonoscopy. Two questionnaires, one for patients reporting acceptability and the other for endoscopists evaluating bowel cleansing effectiveness according to validated scales, were completed. Indications, timing of examination and endoscopical findings were recorded. Biopsy forceps were used as a measuring tool in order to determine polyp endoscopic size estimation. Difficulty in completing the preparation was rated in a 5-point Likert scale (1 = easy to 5 = unable). Adverse experiences (fullness, cramps, nausea, vomiting, abdominal pain, headache and insomnia), number of evacuations and types of activities performed during preparation (walking or resting in bed) were also investigated. Seventy-two patients were selected for each group. The two groups were age and sex matched as well as being comparable in terms of medical history and drug therapies taken. Fourteen patients dropped out from the trial because they did not complete the preparation procedure. Ratings of global bowel cleansing examinations were considered to be adequate in 91% of PEG + Asc and 88% of PEG + Sim patients. Residual Stool Score indicated similar levels of amount and consistency of residual stool; there was a significant difference in the percentage of bowel wall visualization in favour of PEG + Sim patients. In the PEG + Sim group, 12 adenomas ≤ 10 mm diameter (5/left colon + 7/right colon) vs 9 (8/left colon + 1/right colon) in the PEG + Asc group were diagnosed. Visualization of small lesions seems to be one of the primary advantages of the PEG + Sim preparation. PEG + Asc is a good alternative solution as a bowel preparation but more improvements are necessary in order to achieve the target of a perfect preparation.
... products that women commonly use. These include some soaps, shower and bath products, laundry products, panty liners ... makes them feel more uncomfortable. Frequent washing with soap and other cleansing products also can increase pain ...
Hoefte, Rosemarijn
2014-01-01
In 1915 the Rockefeller Foundation took its hookworm eradication campaign to Suriname, but was soon disappointed because of opposition from its main target group: the Javanese. Moreover, authorities and planters objected to the construction of latrines because of the costs and their belief that the Javanese were "unhygienic". In describing the labor migration from Java to Suriname, I show that this "lack of hygiene" was closely related to the system's organization. I argue that uncleanliness was the consequence of harmful socio-economic and ecological conditions. Secondly I suggest that even though the Foundation did not manage to cleanse Suriname of hookworm, its educational efforts, its emphasis on prevention, and its training of local health workers probably had more impact than Rockefeller officials thought.
National Athletic Trainers' Association Position Statement: Management of Acute Skin Trauma
Beam, Joel W.; Buckley, Bernadette; Holcomb, William R.; Ciocca, Mario
2016-01-01
Objective: To present recommendations for the cleansing, debridement, dressing, and monitoring of acute skin trauma in patients. Background: Acute skin trauma is common during participation in athletic and recreational activities. Clinical decisions and intervention protocols after injury vary among athletic trainers and are often based on ritualistic practices. An understanding of cleansing, debridement, and dressing techniques; clinical features of infection and adverse reactions; and monitoring of acute skin trauma is critical for certified athletic trainers and other allied health and medical professionals to create a local wound environment that promotes healing and lessens the risk of complications. Recommendations: These guidelines are intended to provide the certified athletic trainer and others participating in athletic health care with specific knowledge about and recommendations for the management of acute skin trauma. PMID:28092169
National Athletic Trainers' Association Position Statement: Management of Acute Skin Trauma.
Beam, Joel W; Buckley, Bernadette; Holcomb, William R; Ciocca, Mario
2016-12-01
To present recommendations for the cleansing, debridement, dressing, and monitoring of acute skin trauma in patients. Acute skin trauma is common during participation in athletic and recreational activities. Clinical decisions and intervention protocols after injury vary among athletic trainers and are often based on ritualistic practices. An understanding of cleansing, debridement, and dressing techniques; clinical features of infection and adverse reactions; and monitoring of acute skin trauma is critical for certified athletic trainers and other allied health and medical professionals to create a local wound environment that promotes healing and lessens the risk of complications. These guidelines are intended to provide the certified athletic trainer and others participating in athletic health care with specific knowledge about and recommendations for the management of acute skin trauma.
Evaluation of cleansing methods for previously worn prostheses.
Glass, R Thomas; Conrad, Robert S; Bullard, James W; Goodson, Leigh B; Mehta, Naresh; Lech, Stanley J; Loewy, Zvi G
2011-04-01
Although there are many product claims that address the issue of denture sanitization, controlled scientific studies on previously worn dentures have not been performed. The purpose of this study was to evaluate procedures directed at sanitizing previously worn contaminated dentures from two regions of the United States. This study examined 51 previously worn dentures from two regions. An established method of denture retrieval, sectioning, and culturing was used, including isolation of anaerobes. Evaluation of microbial contamination posttreatment was used to determine the effects of soaking dentures in Polident (US and European formulations) for varying periods of times/temperatures, microwaving dentures with varying temperatures, sonicating dentures, and immersing the dentures while using a vacuum. A combination of analysis of variance (ANOVA) and general linear model (GLM) of the SPSS was used to analyze the data with P < .05 being considered statistically significant when using a two-tailed test. While all Polident treatments were found to significantly reduce microorganism loads in dentures, extended soaking (8 hours) and 65 degrees C (5 minutes) were the most effective. Microwaving was slightly more effective than either sonication or vacuum. Regardless the treatment, dentures underwent sanitization rather than sterilization. Denture-borne microorganisms can be significantly reduced by using a Polident solution for 8 hours at room temperature or for 5 minutes at 65 degrees C. Microwaving, sonication, and use of a vacuum were less effective. ClLINICAL IMPLICATIONS The importance of daily use of Polident solution for 8 hours or for 5 minutes at 65 degrees C to sanitize worn prostheses must be stressed.
Gallbladder Cleanse: A "Natural" Remedy for Gallstones?
... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization and proceeds from Web advertising help support our mission. Mayo Clinic does not ...
[Accelerated postoperative recovery after colorectal surgery].
Alfonsi, P; Schaack, E
2007-01-01
Accelerated recovery programs are clinical pathways which outline the stages, and streamline the means, and techniques aiming toward the desired end a rapid return of the patient to his pre-operative physical and psychological status. Recovery from colo-rectal surgery may be slowed by the patient's general health, surgical stress, post-surgical pain, and post-operative ileus. Both surgeons and anesthesiologists participate throughout the peri-operative period in a clinical pathway aimed at minimizing these delaying factors. Key elements of this pathway include avoidance of pre-operative colonic cleansing, early enteral feeding, and effective post-operative pain management permitting early ambulation (usually via thoracic epidural anesthesia). Pre-operative information and motivation of the patient is also a key to the success of this accelerated recovery program. Studies of such programs have shown decreased duration of post-operative ileus and hospital stay without an increase in complications or re-admissions. The elements of the clinical pathway must be regularly re-evaluated and updated according to local experience and published data.
Polyethylene glycol 3350 based colon cleaning protocol: 2 d vs 4 d head to head comparison.
Elitsur, Rotem; Butcher, Lisa; Vicki, Lund; Elitsur, Yoram
2013-04-16
To compare between 2 and 4 d colon cleansing protocols. Children who were scheduled for colonoscopy procedure (2010-2012) for various medical reasons, were recruited from the pediatric gastroenterology clinic at Marshall University School of Medicine, Huntington, WV. Exclusion criteria were patients who were allergic to the medication used in the protocols [polyethylene glycol (PEG) 3350, Bisacodyl], or children with metabolic or renal diseases. Two PEG 3350 protocols for 4 d (A) and 2 d (B) were prescribed as previously described. A questionnaire describing the volume of PEG consumed, clinical data, and side effects were recorded. Colon preparation was graded by two observers according to previously described method. Rate of adequate colon preparation. A total of 78 patients were considered for final calculation (group A: 40, group B: 38). Age and stool consistency at the last day was comparable in both groups, but the number of stools/day was significantly higher in group B (P = 0.001). Adequate colon preparation was reached in 57.5% (A) and 73.6% (B), respectively (P = 0.206). Side effects were minimal and comparable in both groups. There was no difference in children's age, stool characteristics, or side effects between the children with adequate or inadequate colon preparation. Correlation and agreement between observers was excellent (Pearson correlation = 0.972, kappa = 1.0). No difference between protocols was observed, but the 2 d protocol was superior for its shorter time. Direct comparison between different colon cleansing protocols is crucial in order to establish the "gold standard" protocol for children.
A Load-Based Temperature Prediction Model for Anomaly Detection
NASA Astrophysics Data System (ADS)
Sobhani, Masoud
Electric load forecasting, as a basic requirement for the decision-making in power utilities, has been improved in various aspects in the past decades. Many factors may affect the accuracy of the load forecasts, such as data quality, goodness of the underlying model and load composition. Due to the strong correlation between the input variables (e.g., weather and calendar variables) and the load, the quality of input data plays a vital role in forecasting practices. Even if the forecasting model were able to capture most of the salient features of the load, a low quality input data may result in inaccurate forecasts. Most of the data cleansing efforts in the load forecasting literature have been devoted to the load data. Few studies focused on weather data cleansing for load forecasting. This research proposes an anomaly detection method for the temperature data. The method consists of two components: a load-based temperature prediction model and a detection technique. The effectiveness of the proposed method is demonstrated through two case studies: one based on the data from the Global Energy Forecasting Competition 2014, and the other based on the data published by ISO New England. The results show that by removing the detected observations from the original input data, the final load forecast accuracy is enhanced.
Use of Powder PEG-3350 as a Sole Bowel Preparation: Clinical Case Series of 245 Patients.
Arora, Manish; Okolo, Patrick I
2008-07-01
To assess the efficacy of low-volume powder polyethylene glycol (PEG)-3350 as a sole bowel preparation for colonoscopy. This case series examined 245 consecutive patients (a mixture of inpatients and outpatients undergoing screening colonoscopy) at a hospital endoscopy center over a 2-year period. The patients received powder PEG-3350 in the amount of 204 g dissolved in 32 oz of water and taken in 3 divided doses 1 hour apart with 8 oz of water in between each dose. Colon preparation scores (CPS) were used to assess the quality of colon cleansing. The results obtained from the 245 patients were collated and compared to those of patients receiving sodium phosphate, the historical control. The mean CPS was calculated to be 3.43, with a standard deviation of 1.12. Of the 245 patients, 92 were scored with a grade of 4, and 5 patients had incomplete colonoscopies secondary to failure of bowel preparation (CPS=0). Among the remaining patients, 22 and 26 were graded as poor (CPS=1) or fair (CPS=2) bowel preparations, respectively. The low-volume powder PEG-3350 formula used in our case series showed effective colon cleansing and may be considered for use as a sole bowel preparation.
Use of Powder PEG-3350 as a Sole Bowel Preparation
Arora, Manish
2008-01-01
Objective: To assess the efficacy of low-volume powder polyethylene glycol (PEG)-3350 as a sole bowel preparation for colonoscopy. Methods: This case series examined 245 consecutive patients (a mixture of inpatients and outpatients undergoing screening colonoscopy) at a hospital endoscopy center over a 2-year period. The patients received powder PEG-3350 in the amount of 204 g dissolved in 32 oz of water and taken in 3 divided doses 1 hour apart with 8 oz of water in between each dose. Colon preparation scores (CPS) were used to assess the quality of colon cleansing. The results obtained from the 245 patients were collated and compared to those of patients receiving sodium phosphate, the historical control. Results: The mean CPS was calculated to be 3.43, with a standard deviation of 1.12. Of the 245 patients, 92 were scored with a grade of 4, and 5 patients had incomplete colonoscopies secondary to failure of bowel preparation (CPS=0). Among the remaining patients, 22 and 26 were graded as poor (CPS=1) or fair (CPS=2) bowel preparations, respectively. Conclusion: The low-volume powder PEG-3350 formula used in our case series showed effective colon cleansing and may be considered for use as a sole bowel preparation. PMID:21960925
... and filling it with a cleansing fluid (dialysis solution). The solution contains a type of sugar that draws out ... blood vessels through the peritoneum and into the solution. After a set amount of time, the solution ...
LAND APPLICATION AND SLUDGE TREATMENT
Fecal matter potentially containing pathogenic microorganisms and chemical contaminants enters community wastewater collection systems from hospitals, funeral homes, animal slaughtering operations, and dwellings. While these wastewaters are cleansed in the wastewater treatment p...
The effect of topical treatments for CRS on the sinonasal epithelial barrier.
Ramezanpour, M; Rayan, A; Smith, J L P; Vreugde, S
2017-06-01
Several topical treatments are used in the management of Chronic Rhinosinusitis (CRS), some of which the safety and efficacy has yet to be determined. The purpose of this study was to investigate the effect of commonly used topical treatments on the sinonasal epithelial barrier. Normal saline (0.9% Sodium Chloride), hypertonic saline (3% Sodium Chloride), FESS Sinu-Cleanse Hypertonic, FLO Sinus Care and Budesonide 1 mg/ 2 ml were applied to the apical side of air-liquid interface (ALI) cultures of primary human nasal epithelial cells (HNECs) from CRS patients (n=3) and non-CRS controls (n=3) for 24 hours. Epithelial barrier structure and function was assessed using trans-epithelial electrical resistance (TEER), measuring the passage of Fluorescein Isothiocyanate labelled Dextrans (FITC-Dextrans) and assessing the expression of the tight junction protein Zona Occludens-1 (ZO-1) using immunofluorescence. Toxicity was assessed using a Lactate Dehydrogenase (LDH) assay. Data was analysed using ANOVA, followed by Tukey HSD post hoc test. Hypertonic solution and budesonide significantly increased TEER values in CRS derived HNECs. In contrast, FESS Sinu-Cleanse Hypertonic significantly reduced TEER 5 minutes after application of the solution followed by an increase in paracellular permeability of FITC-Dextrans (30 minutes) and increased LDH levels 6 hours after application of the solution. Our findings confirm that isotonic and hypertonic saline solutions do not compromise epithelial barrier function in vitro but underscore the importance of examining safety and efficacy of over-the-counter wash solutions.
Klarin, Bengt; Molin, Göran; Jeppsson, Bengt; Larsson, Anders
2008-01-01
Introduction Ventilator-associated pneumonia (VAP) is usually caused by aspiration of pathogenic bacteria from the oropharynx. Oral decontamination with antiseptics, such as chlorhexidine (CHX) or antibiotics, has been used as prophylaxis against this complication. We hypothesised that the probiotic bacteria Lactobacillus plantarum 299 (Lp299) would be as efficient as CHX in reducing the pathogenic bacterial load in the oropharynx of tracheally intubated, mechanically ventilated, critically ill patients. Methods Fifty critically ill patients on mechanical ventilation were randomised to either oral mechanical cleansing followed by washing with 0.1% CHX solution or to the same cleansing procedure followed by oral application of an emulsion of Lp299. Samples for microbiological analyses were taken from the oropharynx and trachea at inclusion and at defined intervals thereafter. Results Potentially pathogenic bacteria that were not present at inclusion were identified in oropharyngeal samples from eight of the patients treated with Lp299 and 13 of those treated with CHX (p = 0.13). Analysis of tracheal samples yielded similar results. Lp299 was recovered from the oropharynx of all patients in the Lp299 group. Conclusions In this pilot study, we found no difference between the effect of Lp299 and CHX used in oral care procedures, when we examined the effects of those agents on colonisation of potentially pathogenic bacteria in the oropharynx of intubated, mechanically ventilated patients. PMID:18990201
NASA Astrophysics Data System (ADS)
Goren, Tom; Muelmenstaedt, Johannes; Rosenfeld, Daniel; Quaas, Johannes
2017-04-01
Marine stratocumulus clouds (MSC) occur in two main cloud regimes of open and closed cells that differ significantly by their cloud cover. Closed cells gradually get cleansed of high CCN concentrations in a process that involves initiation of drizzle that breaks the full cloud cover into open cells. The drizzle creates downdrafts that organize the convection along converging gust fronts, which in turn produce stronger updrafts that can sustain more cloud water that compensates the depletion of the cloud water by the rain. In addition, having stronger updrafts allow the clouds to grow relatively deep before rain starts to deplete its cloud water. Therefore, lower droplet concentrations and stronger rain would lead to lower cloud fraction, but not necessary also to lower liquid water path (LWP). The fundamental relationships between these key variables derived from global climate model (GCM) simulations are analyzed with respect to observations in order to determine whether the GCM parameterizations can represent well the governing physical mechanisms upon MSC regime transitions. The results are used to evaluate the feasibility of GCM's for estimating aerosol cloud-mediated radiative forcing upon MSC regime transitions, which are responsible for the largest aerosol cloud-mediated radiative forcing.
Kassouf, Nick; Syed, Sara; Larner, Joanne; Amlôt, Richard
2017-01-01
The UK’s Initial Operational Response (IOR) is a revised process for the medical management of mass casualties potentially contaminated with hazardous materials. A critical element of the IOR is the introduction of immediate, on-scene disrobing and decontamination of casualties to limit the adverse health effects of exposure. Ad hoc cleansing of the skin with dry absorbent materials has previously been identified as a potential means of facilitating emergency decontamination. The purpose of this study was to evaluate the in vitro oil and water absorbency of a range of materials commonly found in the domestic and clinical environments and to determine the effectiveness of a small, but representative selection of such materials in skin decontamination, using an established ex vivo model. Five contaminants were used in the study: methyl salicylate, parathion, diethyl malonate, phorate and potassium cyanide. In vitro measurements of water and oil absorbency did not correlate with ex vivo measurements of skin decontamination. When measured ex vivo, dry decontamination was consistently more effective than a standard wet decontamination method (“rinse-wipe-rinse”) for removing liquid contaminants. However, dry decontamination was ineffective against particulate contamination. Collectively, these data confirm that absorbent materials such as wound dressings and tissue paper provide an effective, generic capability for emergency removal of liquid contaminants from the skin surface, but that wet decontamination should be used for non-liquid contaminants. PMID:28152053
Optimal Bowel Preparation for Video Capsule Endoscopy
Song, Hyun Joo; Moon, Jeong Seop; Shim, Ki-Nam
2016-01-01
During video capsule endoscopy (VCE), several factors, such as air bubbles, food material in the small bowel, and delayed gastric and small bowel transit time, influence diagnostic yield, small bowel visualization quality, and cecal completion rate. Therefore, bowel preparation before VCE is as essential as bowel preparation before colonoscopy. To date, there have been many comparative studies, consensus, and guidelines regarding different kinds of bowel cleansing agents in bowel preparation for small bowel VCE. Presently, polyethylene glycol- (PEG-) based regimens are given primary recommendation. Sodium picosulphate-based regimens are secondarily recommended, as their cleansing efficacy is less than that of PEG-based regimens. Sodium phosphate as well as complementary simethicone and prokinetics use are considered. In this paper, we reviewed previous studies regarding bowel preparation for small bowel VCE and suggested optimal bowel preparation of VCE. PMID:26880894
Role of laser photoablative therapy and expandable metal stents in colorectal carcinoma
NASA Astrophysics Data System (ADS)
Chennupati, Raja S.; Trowers, Eugene A.
2000-05-01
Metallic stents are effective in relieving colorectal obstruction in more than 80% of cases. Self expanding metallic stents allow for decompression of the proximal colon and preoperative bowel cleansing. Hence, emergent surgery for large bowel obstruction with its associated high morbidity and mortality might be avoided. Endoscopic laser photoablation and stent placement may successfully palliate inoperable colorectal cancer patients by maintaining luminal patency and avoiding the need for a colostomy. Major complications associated with metallic stents include pressure necrosis, perforation, bleeding and migration. The effectiveness of expandable metallic stents in obstructive colorectal carcinoma is critically reviewed. The authors present a concise review of the effectiveness of endoscopic laser photoablation and expandable metal stent placement.
NuLYTELY (PEG 3350, sodium chloride, sodium bicarbonate and potassium chloride for oral solution).
Swartz, M L
1992-02-01
NuLYTELY (PEG 3350, Sodium Chloride, Sodium Bicarbonate, and Potassium Chloride for Oral Solution), a product from Braintree Laboratories, Inc. is a modification of GoLYTELY (PEG 3350 and Electrolytes for Oral Solution) that has been found to have the same therapeutic advantages in terms of safety, efficacy, speed and patient acceptance. This product was developed to improve upon the taste of GoLYTELY. NuLYTELY represents an effective alternative for bowel cleansing prior to colonoscopy that may be more acceptable to some patients.
21 CFR 524.2101 - Selenium disulfide suspension.
Code of Federal Regulations, 2010 CFR
2010-04-01
... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...
21 CFR 524.2101 - Selenium disulfide suspension.
Code of Federal Regulations, 2012 CFR
2012-04-01
... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...
21 CFR 524.2101 - Selenium disulfide suspension.
Code of Federal Regulations, 2014 CFR
2014-04-01
... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...
21 CFR 524.2101 - Selenium disulfide suspension.
Code of Federal Regulations, 2013 CFR
2013-04-01
... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...
21 CFR 524.2101 - Selenium disulfide suspension.
Code of Federal Regulations, 2011 CFR
2011-04-01
... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...
30 CFR 47.11 - Definitions of terms used in this part.
Code of Federal Regulations, 2011 CFR
2011-07-01
... drugs (1) Cosmetics are any article applied to the human body for cleansing, beautifying, promoting... the body of humans or other animals. CPSC The U.S. Consumer Product Safety Commission. Designated...
30 CFR 47.11 - Definitions of terms used in this part.
Code of Federal Regulations, 2010 CFR
2010-07-01
... drugs (1) Cosmetics are any article applied to the human body for cleansing, beautifying, promoting... the body of humans or other animals. CPSC The U.S. Consumer Product Safety Commission. Designated...
Polyethylene glycol 3350 based colon cleaning protocol: 2 d vs 4 d head to head comparison
Elitsur, Rotem; Butcher, Lisa; Vicki, Lund; Elitsur, Yoram
2013-01-01
AIM: To compare between 2 and 4 d colon cleansing protocols. METHODS: Children who were scheduled for colonoscopy procedure (2010-2012) for various medical reasons, were recruited from the pediatric gastroenterology clinic at Marshall University School of Medicine, Huntington, WV. Exclusion criteria were patients who were allergic to the medication used in the protocols [polyethylene glycol (PEG) 3350, Bisacodyl], or children with metabolic or renal diseases. Two PEG 3350 protocols for 4 d (A) and 2 d (B) were prescribed as previously described. A questionnaire describing the volume of PEG consumed, clinical data, and side effects were recorded. Colon preparation was graded by two observers according to previously described method. Main outcome measurements: Rate of adequate colon preparation. RESULTS: A total of 78 patients were considered for final calculation (group A: 40, group B: 38). Age and stool consistency at the last day was comparable in both groups, but the number of stools/day was significantly higher in group B (P = 0.001). Adequate colon preparation was reached in 57.5% (A) and 73.6% (B), respectively (P = 0.206). Side effects were minimal and comparable in both groups. There was no difference in children’s age, stool characteristics, or side effects between the children with adequate or inadequate colon preparation. Correlation and agreement between observers was excellent (Pearson correlation = 0.972, kappa = 1.0). CONCLUSION: No difference between protocols was observed, but the 2 d protocol was superior for its shorter time. Direct comparison between different colon cleansing protocols is crucial in order to establish the “gold standard” protocol for children. PMID:23596539
Korting, H C; Hübner, K; Greiner, K; Hamm, G; Braun-Falco, O
1990-01-01
Skin cleansing preparations consisting of identical synthetic detergents but differing in pH-value (pH 5.5 and 7.0) were applied twice daily on the forehead and forearm of healthy volunteers in a randomized crossover trial. The skin surface pH was found to be significantly higher when the neutral preparation had been used, as was the propionibacterial count (p less than 0.05). The number of propionibacteria was significantly linked to the skin pH. Hence even minor differences in the pH of skin cleansing preparations seem to be of importance for the integrity of the skin surface. This should be taken into account when planning the formulation of optimal skin care products.
The failures of root canal preparation with hand ProTaper.
Bătăiosu, Marilena; Diaconu, Oana; Moraru, Iren; Dăguci, C; Tuculină, Mihaela; Dăguci, Luminiţa; Gheorghiţă, Lelia
2012-07-01
The failures of root canal preparation are due to some anatomical deviation (canal in "C" or "S") and some technique errors. The technique errors are usually present in canal root cleansing and shaping stage and are the result of endodontic treatment objectives deviation. Our study was made on technique errors while preparing the canal roots with hand ProTaper. Our study was made "in vitro" on 84 extracted teeth (molars, premolars, incisors and canines). The canal root of these teeth were cleansed and shaped with hand ProTaper by crown-down technique and canal irrigation with NaOCl(2,5%). The dental preparation control was made by X-ray. During canal root preparation some failures were observed like: canal root overinstrumentation, zipping and stripping phenomenon, discarded and/or fractured instruments. Hand ProTaper represents a revolutionary progress of endodontic treatment, but a deviation from accepted rules of canal root instrumentation can lead to failures of endodontic treatment.
Dirty liberals! Reminders of physical cleanliness influence moral and political attitudes.
Helzer, Erik G; Pizarro, David A
2011-04-01
Many moral codes place a special emphasis on bodily purity, and manipulations that directly target bodily purity have been shown to influence a variety of moral judgments. Across two studies, we demonstrated that reminders of physical purity influence specific moral judgments regarding behaviors in the sexual domain as well as broad political attitudes. In Study 1, individuals in a public setting who were given a reminder of physical cleansing reported being more politically conservative than did individuals who were not given such a reminder. In Study 2, individuals reminded of physical cleansing in the laboratory demonstrated harsher moral judgments toward violations of sexual purity and were more likely to report being politically conservative than control participants. Together, these experiments provide further evidence of a deep link between physical purity and moral judgment, and they offer preliminary evidence that manipulations of physical purity can influence general (and putatively stable) political attitudes.
Deployment and testing of a second prototype expandable surgical chamber in microgravity
NASA Technical Reports Server (NTRS)
Markham, Sanford M.; Rock, John A.
1991-01-01
During microgravity exposure, two separate expandable surgical chambers were tested. Both chambers had been modified to fit the microgravity work station without extending over the sides of the table. Both chambers were attached to a portable laminar flow generator which served two purposes: to keep the chambers expanded during use; and to provide an operative area environment free of contamination. During the tests, the chambers were placed on various parts of a total body moulage to simulate management of several types of trauma. The tests consisted of cleansing contusions, debridement of burns, and suturing of lacerations. Also, indigo carmine dye was deliberately injected into the chamber during the tests to determine the ease of cleansing the chamber walls after contamination by escaping fluids. Upon completion of the tests, the expandable surgical chambers were deflated, folded, and placed in a flattened state back into their original containers for storage and later disposal. Results are briefly discussed.
Ogunshe, Adenike A O; Omotoso, Oluwatoyin A; Akindele, Titilayo M
2011-06-01
The study aims at evaluating the potentials of soaps and germicides/disinfectants as adjunct topical anti-vulvovaginal candidasis agents. In vitro inhibitory activities of the test agents, prepared according to the manufacturer's specification for toilet and midwifery purposes were determined using modified agar well-diffusion method. Varied susceptibility patterns were exhibited by Candida albicans (26.5%), C. glabrata (18.4%), C. pseudotropicalis (14.3%) and C. tropicalis (40.8%) implicated in vulvovaginal candidasis, indicating Crusader oil (100%), Meriko (95%), Tetmosol (84.7%) and Aloe (68.4%) as the most inhibitory soaps against the Candida strains. The in vitro inhibitory activities of the germicides and disinfectants ranged between (Dettol; 34.6% and Purit; 84.6%) for C. albicans; (Roberts; 33.3% and Purit; 83.3%) for C. glabrata; (Roberts; 21.4% and Purit; 92.9%) for C. pseudotropicalis; (Dettol; 35.0% and Purit; 87.5%) for C. tropicalis respectively. All the Candida strains were totally inhibited by the germicides and disinfectants at the second lower dilutions, except in Morigad towards C. albicans (69.2%]) C. glabrata (72.2%), C. pseudotropicalis (92.9%) and C. tropicalis (82.5%) but none of the vaginal Lactobacillus strains was inhibited by the soaps, germicides or disinfectant. About 90% of a control group indicated relief after pubic cleansing with soaps, germicides and disinfectants. Results indicatied the safety of soaps, germicides and disinfectants as potential adjunct topical cleansing-agents in cases of vaginal itching and candidasis, a common mucosal infection caused by opportunistic yeasts of the Candida genus.
MANAGEMENT OF HOUSEHOLD AND SMALL-QUANTITY-GENERATOR HAZARDOUS WASTE IN THE UNITED STATES
The International Solid Waste and Public Cleansing Association (ISWA), an international nongovernmental organization comprising twenty-seven national organizations of waste management professionals, conducted a survey to obtain information regarding household and small-quantity-g...
Mahler, V; Erfurt-Berge, C; Schiemann, S; Michael, S; Egloffstein, A; Kuss, O
2010-04-01
In occupational fields with exposure to grease, oil, metal particles, coal, black lead or soot, cleansing formulations containing abrasive bodies (e.g. refined walnut shell, corn, wood, plastic or pumice) are used. These may constitute an irritant per se. As an alternative, hydrogenated castor oil (also known as castor wax) beads have been developed as dirt-binding particles. A polar surface contributes to their mechanical cleaning effects in removal of oily grime. Standardized examination of the in vivo effects upon the skin barrier of castor wax beads in comparison with abrasive bodies and pure detergent. Three cleansing preparations - (i) detergent, (ii) detergent containing castor wax beads, (iii) detergent containing walnut shell powder - were each repetitively applied in vivo (four times daily for 3 weeks), mimicking workplace conditions, in 30 healthy volunteers (15 with and 15 without an atopic skin diathesis) and compared vs. (iv) no treatment. The treatment effects upon the skin barrier were monitored by repeated measurements of functional parameters [transepidermal water loss (TEWL), redness] and surface topography. After a 3-week treatment, a significant global treatment effect (P < 0.0001) was found in the atopic group concerning TEWL as indicator for barrier function. A significantly higher TEWL and increasing erythema in the area treated with detergent containing walnut shell powder reflected its irritant effect compared with castor wax beads dispensed in the identical detergent. Cleaning properties of the two formulas were comparably superior to detergent alone. Castor wax beads constitute a novel nonirritating alternative for abrasive cleaning of recalcitrant oily skin contamination appropriate for individuals with an atopic skin diathesis in a three-step programme of occupational skin protection. As the skin barrier may additionally be influenced by the composition of dirt and use of skin protection and skin care measures under real workplace conditions, this component may now be used and examined further in different occupations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Albertson, O.E.; Baturay, A.
1990-04-17
This patent describes the method for disposal of waste organic sludge of the type which contains at least one certain waste material that is either a low melting eutectic that softens or heavy metal that fumes at the highest temperature required to effect incineration of the sludge and cleansing by burning of the resultant gases. It comprises: the steps of combusting the sludge in a single combustion mass overlain by a gas-filled freeboard thereby to effect burning of substantially the entire content of combustible solids while yielding wet gases which contain entrained particulates as well as combustible and non-combustible constituents,more » volatiles and condensible matter.« less
... you may have a small notch in the edge of the eyelid. The most common complication is ... It may help to gently scrub the edge of the lid at the eyelash line nightly to prevent chalazia or styes. Use eye cleansing pads or diluted baby shampoo. Apply antibiotic ...
Diffusion pump modification promotes self-cleansing and high efficiency
NASA Technical Reports Server (NTRS)
Buggele, A. E.
1975-01-01
Modifications eliminate contaminant substances from pump fluid during operation, which are principal causes of torpidity on evaporative surface. Diffusion pump is also acting as still. Resulting 100 percent vigorous working surface provides much greater molecular throughput and greatly improved efficiency.
Heinzelmann, Elsbeth
2016-01-01
The year 1958, when DNA was first made in a test tube, marked the birth of modern biotechnology. DNA has now developed into an important technology that makes a key contribution in various sectors such as agriculture, environment and cleansing, and it has triggered a veritable boom in medicine. Today, biologics account for more than 60% of newly approved drugs. They are efficient, save time and money and have few or minimal side effects, fuelling the appetite of big pharma to take over biotech companies. Where will the journey lead?
Application of lasers in endodontics
NASA Astrophysics Data System (ADS)
Ertl, Thomas P.; Benthin, Hartmut; Majaron, Boris; Mueller, Gerhard J.
1997-12-01
Root canal treatment is still a problem in dentistry. Very often the conventional treatment fails and several treatment sessions are necessary to save the tooth from root resection or extraction. Application of lasers may help in this situation. Bacteria reduction has been demonstrated both in vitro and clinically and is either based on laser induced thermal effects or by using an ultraviolet light source. Root canal cleansing is possible by Er:YAG/YSGG-Lasers, using the hydrodynamic motion of a fluid filled in the canals. However root canal shaping using lasers is still a problem. Via falsas and fiber breakage are points of research.
Tekgündüz, Kadir Şerafettin; Kepenekli, Eda; Demirelli, Yaşar; Caner, İbrahim; Kara, Mustafa
2016-10-01
Newborns are more susceptible to infection; this makes proper wound care extremely important in them. Unfortunately, in spite of successful surgery, patients can die as a result of wound area infections. Herein, we report a case in which a combined therapy of chlorhexidine (a disinfectant) and saline (a cleansing agent used in wound care) was used effectively to treat the wound in a newborn infant with an antibiotic-resistant, Gram-negative, bacteria-related surgical site infection. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Safari, Mir Jafar Sadegh; Shirzad, Akbar; Mohammadi, Mirali
2017-08-01
May proposed two dimensionless parameters of transport (η) and mobility (F s ) for self-cleansing design of sewers with deposited bed condition. The relationships between those two parameters were introduced in conditional form for specific ranges of F s , which makes it difficult to use as a practical tool for sewer design. In this study, using the same experimental data used by May and employing the particle swarm optimization algorithm, a unified equation is recommended based on η and F s . The developed model is compared with original May relationships as well as corresponding models available in the literature. A large amount of data taken from the literature is used for the models' evaluation. The results demonstrate that the developed model in this study is superior to May and other existing models in the literature. Due to the fact that in May's dimensionless parameters more effective variables in the sediment transport process in sewers with deposited bed condition are considered, it is concluded that the revised May equation proposed in this study is a reliable model for sewer design.
Amin, Nuhu; Pickering, Amy J.; Ram, Pavani K.; Unicomb, Leanne; Najnin, Nusrat; Homaira, Nusrat; Ashraf, Sania; Abedin, Jaynal; Islam, M. Sirajul; Luby, Stephen P.
2014-01-01
We conducted a randomized, non-inferiority field trial in urban Dhaka, Bangladesh among mothers to compare microbial efficacy of soapy water (30 g powdered detergent in 1.5 L water) with bar soap and water alone. Fieldworkers collected hand rinse samples before and after the following washing regimens: scrubbing with soapy water for 15 and 30 seconds; scrubbing with bar soap for 15 and 30 seconds; and scrubbing with water alone for 15 seconds. Soapy water and bar soap removed thermotolerant coliforms similarly after washing for 15 seconds (mean log10 reduction = 0.7 colony-forming units [CFU], P < 0.001 for soapy water; mean log10 reduction = 0.6 CFU, P = 0.001 for bar soap). Increasing scrubbing time to 30 seconds did not improve removal (P > 0.05). Scrubbing hands with water alone also reduced thermotolerant coliforms (mean log10 reduction = 0.3 CFU, P = 0.046) but was less efficacious than scrubbing hands with soapy water. Soapy water is an inexpensive and microbiologically effective cleansing agent to improve handwashing among households with vulnerable children. PMID:24914003
ERIC Educational Resources Information Center
Macedo, Donaldo; Gounari, Panayota
2005-01-01
Addressing ethnic cleansing, culture wars, human sufferings, terrorism, immigration, and intensified xenophobia, "Globalization of Racism" explains why it is vital that we gain a nuanced understanding of how ideology underlies all social, cultural, and political discourse and racist actions. The book looks at recent developments in…
21 CFR 524.1484c - Neomycin sulfate, isoflupredone acetate, tetracaine hydrochloride ointment.
Code of Federal Regulations, 2010 CFR
2010-04-01
... conditions of the external ear canal, a quantity of ointment sufficient to fill the external ear canal may be... cleansed, and a small amount of the ointment applied and spread or rubbed in gently. The involved area may...
21 CFR 524.1484c - Neomycin sulfate, isoflupredone acetate, tetracaine hydrochloride ointment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... conditions of the external ear canal, a quantity of ointment sufficient to fill the external ear canal may be... cleansed, and a small amount of the ointment applied and spread or rubbed in gently. The involved area may...
Soil carbon sequestration: Quantifying this ecosystem service
Soils have a crucial role in supplying many goods and services that society depends upon on a daily basis. These include food and fiber production, water cleansing and supply, nutrient cycling, waste isolation and degradation. Soils also provide a significant amount of carbon s...
Interdisciplinary Coordination Reviews: A Process to Reduce Construction Costs.
ERIC Educational Resources Information Center
Fewell, Dennis A.
1998-01-01
Interdisciplinary Coordination design review is instrumental in detecting coordination errors and omissions in construction documents. Cleansing construction documents of interdisciplinary coordination errors reduces time extensions, the largest source of change orders, and limits exposure to liability claims. Improving the quality of design…
Landin, Wendell E; Mun, Greg C; Nims, Raymond W; Harbell, John W
2007-09-01
The cytosensor microphysiometer (mu phi) was investigated as a rapid, relatively inexpensive test to predict performance of skin cleansing wipes on the human 21-day cumulative irritation patch test (21CIPT). It indirectly measures metabolic rate changes in L929 cells as a function of test article dose, by measuring the acidification rate in a low-buffer medium. The dose producing a 50% reduction in metabolic rate (MRD50), relative to the baseline rate, is used as a measure of toxicity. The acute toxicity of the mu phi assay can be compared to the chronic toxicity of the 21CIPT, which is based largely on the exposure of test agents to the epidermal cells, resulting in damage and penetration of the stratum corneum leading to cell toxicity. Two series of surfactant-based cleansing wipe products were tested via the mu phi assay and 21CIPT. The first series, consisting of 20 products, was used to determine a prediction model. The second series of 38 products consisted of routine product development formulas or marketed products. Comparing the results from both tests, samples with an MRD50 greater than 50 mg/ml provided a 21CIPT score consistent with a product that performs satisfactorily in the market. When the MRD50 was greater than 78 mg/ml, the 21CIPT score was usually zero. The mu phi may be more sensitive than the 21CIPT for ranking minimally irritating materials. The mu phi assay is useful as a screen for predicting the performance of a wet wipes formula on the 21CIPT, and concurrently reduces the use of animals for safety testing in a product development program for cleansing wipes.
Ortega-Usobiaga, J; Llovet-Osuna, F; Katz, T; Djodeyre, M R; Druchkiv, V; Bilbao-Calabuig, R; Baviera, J
2018-02-01
To assess visual outcomes of retreatment after laser in situ keratomileusis (LASIK) by lifting the flap or performing photorefractive keratectomy (PRK) on the flap, as well as to establish whether there was an increased risk of epithelial ingrowth (EIG) when LASIK and lifting of the flap are separated by a long time interval and to determine the incidence of corneal haze after PRK. Retrospective study of 4077 patients (5468 eyes) who underwent LASIK and subsequent retreatment were reviewed in order to study their visual results and identify cases of EIG and corneal haze. Enhancements included 5196 eyes from 3876 patients that were retreated by lifting the flap, and 272 eyes from 201 patients that were retreated by PRK on the flap. No statistically significant differences were found between the retreatments in terms of predictability, efficacy, and safety. A total of 704 cases of EIG were found after lifting the flap, for which surgical cleansing was necessary in 70. Surgical cleansing decreased the efficacy index when compared with patients with EIG who did not need cleansing (P=.01). Differences in terms of safety and predictability were not statistically significant. The incidence of corneal haze after ablation of the surface of the previous flap was 14.34%, although none of these cases were clinically relevant. Visual outcomes were similar between patients who were retreated by lifting the flap and those who underwent PRK. The incidence of EIG when the flap was lifted was 13.55%. The incidence of EIG increases with the time elapsed between the primary procedure and retreatment. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
Zhang, Ling-Ye; Li, Wen-Yan; Ji, Ming; Liu, Fu-Kun; Chen, Guang-Yong; Wu, Shan-Shan; Hao, Qian; Zhai, Hui-Hong; Zhang, Shu-Tian
2018-01-01
To investigate the efficacy and safety of premedication with simethicone/Pronase during esophagogastroduodenoscopy (EGD) with sedation. Six hundred and ten patients were randomly allocated to two groups based on type of premedication given. Premedication used in the control group was 10 mL lidocaine hydrochloride mucilage (LHM, N = 314) and premedication used in the intervention group was 80 mL simethicone/Pronase solution plus 10 mL lidocaine hydrochloride mucilage (SP/LHM, N = 296). EGD was done under sedation. Visibility scores, number of mucosal areas that needed cleansing, water consumption for cleansing, time taken for examination, diminutive lesions, pathological diagnosis, patients' gag reflex and oxygenation (pulse oximetry) were recorded. SP/LHM has significantly lower total visibility score than LHM (7.978 ± 1.526 vs 6.348 ± 1.097, P < 0.01). During the procedure, number of intragastric areas that needed cleansing and amount of water consumed were significantly less in the SP/LHM than in the LHM group (P < 0.01). In SP/LHM (P = 0.01), endoscopy procedure duration was significantly longer. Although there was no significant difference in rate of detection of diminutive lesions between LHM and SP/LHM, the endoscopist carried out more biopsies in SP/LHM. This led to a higher rate of diagnosis of atrophic gastritis (P = 0.014) and intestinal metaplasia (P = 0.024). There was no significant difference in gag reflex (P = 0.604) and oxygenation during the endoscopy procedure for either group of patients. Routine use of premedication with simethicone/Pronase should be recommended during EGD with sedation. © 2017 Japan Gastroenterological Endoscopy Society.
Critical Thinking vs. Critical Consciousness
ERIC Educational Resources Information Center
Doughty, Howard A.
2006-01-01
This article explores four kinds of critical thinking. The first is found in Socratic dialogues, which employ critical thinking mainly to reveal logical fallacies in common opinions, thus cleansing superior minds of error and leaving philosophers free to contemplate universal verities. The second is critical interpretation (hermeneutics) which…
2018-02-05
Bacterial Infection; Benign Neoplasm; Malignant Neoplasm; Methicillin-Resistant Staphylococcus Aureus Infection; Recurrent Childhood Acute Lymphoblastic Leukemia; Recurrent Childhood Acute Myeloid Leukemia; Untreated Childhood Myeloid Neoplasm
The failures of root canal preparation with hand ProTaper
Bătăiosu, Marilena; Diaconu, Oana; Moraru, Iren; Dăguci, C.; Ţuculină, Mihaela; Dăguci, Luminiţa; Gheorghiţă, Lelia
2012-01-01
The failures of root canal preparation are due to some anatomical deviation (canal in “C” or “S”) and some technique errors. The technique errors are usually present in canal root cleansing and shaping stage and are the result of endodontic treatment objectives deviation. Objectives: Our study was made on technique errors while preparing the canal roots with hand ProTaper. Methodology: Our study was made “in vitro” on 84 extracted teeth (molars, premolars, incisors and canines). The canal root of these teeth were cleansed and shaped with hand ProTaper by crown-down technique and canal irrigation with NaOCl(2,5%). The dental preparation control was made by X-ray. Results: During canal root preparation some failures were observed like: canal root overinstrumentation, zipping and stripping phenomenon, discarded and/or fractured instruments. Conclusions: Hand ProTaper represents a revolutionary progress of endodontic treatment, but a deviation from accepted rules of canal root instrumentation can lead to failures of endodontic treatment. PMID:24778848
Data Preparation Process for the Buildings Performance Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walter, Travis; Dunn, Laurel; Mercado, Andrea
2014-06-30
The Buildings Performance Database (BPD) includes empirically measured data from a variety of data sources with varying degrees of data quality and data availability. The purpose of the data preparation process is to maintain data quality within the database and to ensure that all database entries have sufficient data for meaningful analysis and for the database API. Data preparation is a systematic process of mapping data into the Building Energy Data Exchange Specification (BEDES), cleansing data using a set of criteria and rules of thumb, and deriving values such as energy totals and dominant asset types. The data preparation processmore » takes the most amount of effort and time therefore most of the cleansing process has been automated. The process also needs to adapt as more data is contributed to the BPD and as building technologies over time. The data preparation process is an essential step between data contributed by providers and data published to the public in the BPD.« less
Role of female intimate hygiene in vulvovaginal health: Global hygiene practices and product usage.
Chen, Ying; Bruning, Elizabeth; Rubino, Joseph; Eder, Scott E
2017-12-01
Women use various feminine hygiene products, often as part of their daily cleansing routine; however, there is a paucity of published medical literature related to the external vulva and how personal hygiene practices can affect it. This review article provides background information on the physiological changes that occur during women's lives and reviews the relevance of transient and resident microbiota as they relate to common vaginal and vulvar disorders. It also discusses the need for female intimate hygiene, common practices of feminine hygiene from a global perspective, and the potential benefits of using suitable external, topical feminine vulvar washes to minimize the risk of vulvovaginal disorders and to improve overall intimate health in women around the world. Supported by international guidelines, daily gentle cleansing of the vulva is an important aspect of feminine hygiene and overall intimate health. Women should be encouraged to choose a carefully formulated and clinically tested external wash that provides targeted antimicrobial and other health benefits without negatively impacting on the natural vulvovaginal microbiota.
Andrealli, Alida; Paggi, Silvia; Amato, Arnaldo; Rondonotti, Emanuele; Imperiali, Gianni; Lenoci, Nicoletta; Mandelli, Giovanna; Terreni, Natalia; Spinzi, Giancarlo; Radaelli, Franco
2018-01-01
Background A split-dose (SD) regimen is crucial for colonoscopy quality. Compliance with SD for early morning colonoscopy is generally poor. The present study evaluated whether pre-colonoscopy counselling, in addition to a dedicated leaflet, might increase SD uptake. Methods Consecutive 50–69-year-old patients undergoing screening colonoscopy before 10 a.m. were randomized to either receive written information only on bowel preparation (Written Group, WG) or written and oral instructions (Written and Oral Group, WaOG). The leaflet strongly encouraged SD adoption. The primary endpoint was the number of patients adopting SD in each group. The secondary endpoints were predictors of SD uptake, compliance with preparation schemes and cleansing adequacy. Results A total of 286 patients (143 WG, 143 WaOG) were enrolled (mean age 59.6 ± 6.1 years, men 49.3%). SD was adopted by 114 and 125 patients in the WG and WaOG, respectively (79.7% versus 87.4%, p = 0.079). No significant differences were observed for the proportion of patients with full compliance with preparation scheme (97.9% versus 97.2%, p = 0.99) and of procedures with adequate bowel cleansing (95.6% versus 95.1%, p = 0.77). At multivariate analysis, a > 1 h travel time to the endoscopy service was inversely correlated with SD uptake (odds ratio (OR) 0.30, 95% confidence interval (CI) 0.09–0.98). Conclusions Our leaflet guaranteed satisfactory uptake of SD and excellent adherence to the preparation scheme for early morning colonoscopy. Its use might marginalize the need for additional oral instructions, particularly in open-access settings. PMID:29511558
The impact of diet liberalization on bowel preparation for colonoscopy.
Walter, James; Francis, Gloria; Matro, Rebecca; Kedika, Ramalinga; Grosso, Rachael; Keith, Scott W; Kastenberg, David
2017-04-01
Background and study aims Dietary restrictions are integral to colonoscopy preparation and impact patient satisfaction. Utilizing split-dose, lower-volume polyethylene glycol 3350-electrolyte solution (PEG-ELS), this study compared colon preparation adequacy of a low-residue diet to clear liquids using a validated grading scale. Patients and methods This was a prospective, randomized, single-blinded, single-center non-inferiority study evaluating diet the day prior to outpatient colonoscopy. Subjects were randomized to a Low-Residue diet for breakfast and lunch, or Clears only. All subjects received split dose PEG-ELS. The primary endpoint was preparation adequacy using the Boston Bowel Preparation Scale (BBPS), with adequate defined as a score > 5. Secondary endpoints included mean BBPS scores for the entire colon and individual segments, satisfaction, adverse events, polyp and adenoma detection rates, and impact on sleep and daily activities. Results Final analysis included 140 subjects, 72 assigned to Clears and 68 to Low-Residue. The Low-Residue diet was non-inferior to Clears (risk difference = - 5.08 %, P = 0.04) after adjusting for age. Mean colon cleansing scores were not significantly different overall and for individual colonic segments. Satisfaction with the Low-Residue diet was significantly greater ( P = 0.01). The adenoma detection rate was not statistically significantly different between study groups, but the number of adenomas detected was significantly greater with Clears ( P = 0.01). Adverse events and impact on sleep and activities did not differ significantly between diet arms. Conclusions A low-residue diet for breakfast and lunch the day prior to colonoscopy was non-inferior to clear liquids alone for achieving adequate colon cleansing when using split dose PEG-ELS.
Dey, Tania; Naughton, Daragh
2017-05-01
Glass surface cleaning is the very first step in advanced coating deposition and it also finds use in conserving museum objects. However, most of the wet chemical methods of glass cleaning use toxic and corrosive chemicals like concentrated sulfuric acid (H 2 SO 4 ), piranha (a mixture of concentrated sulfuric acid and 30% hydrogen peroxide), and hydrogen fluoride (HF). On the other hand, most of the dry cleaning techniques like UV-ozone, plasma, and laser treatment require costly instruments. In this report, five eco-friendly wet chemical methods of glass cleaning were evaluated in terms of contact angle (measured by optical tensiometer), nano-scale surface roughness (measured by atomic force microscopy or AFM), and elemental composition (measured by energy dispersive x-ray spectroscopy or SEM-EDX). These glass cleaning methods are devoid of harsh chemicals and costly equipment, hence can be applied in situ in close proximity with plantation such as greenhouse or upon subtle objects such as museum artifacts. Out of these five methods, three methods are based on the chemical principle of chelation. It was found that the citric acid cleaning method gave the greatest change in contact angle within the hydrophilic regime (14.25° for new glass) indicating effective cleansing and the least surface roughness (0.178 nm for new glass) indicating no corrosive effect. One of the glass sample showed unique features which were traced backed to the history of the glass usage.
Lohitha, K; Prakash, M; Gopinadh, A; Sai Sankar, A J; Sandeep, C H; Sreedevi, B
2016-01-01
Regular usage of denture cleansers is recommended in complete denture wearers for effective plaque control, and these cleansers alter the physical properties of acrylic resin over a period of time. Thus, an in vitro study was carried out to assess the effect of denture cleansers on the color stability of heat-cure denture base resin. The aim of the present study was to evaluate the effect of commercially available fast-acting denture cleansers on the color stability of heat-cure denture base resin at different time intervals. Thirty-six heat-cure acrylic resin (Ivoclar Triplex Hot-V) specimens are randomly allocated into four groups - Group A (distilled water as control); Group B (polident - 3 min); Group C (fixodent scope plus); and Group D (stain away plus) comprising of nine samples each. After recording the baseline values, the specimens were immersed in their respective cleansing solutions for a prescribed time interval. This procedure was repeated daily, and the color change (ΔE) was evaluated after 90 and 180 days interval using a colorimeter in a standard "Commission International de l'Eclairage" color system. Paired t -test and Dunnett's T3 test. All the groups exhibited a variable color change (ΔE) for an immersion period of 90 days. However, significant color differences ( P = 0.001) were noticed among the test groups after 180 days. The color change of denture base resin was greater for Group D followed by Groups B, C, and A respectively after 180 days of immersion. The ΔE values of all test groups increased with time.
Sendero Luminoso: Case Study in Insurgency
1993-01-01
utopia is premised on the spiritual rejuvenation of its chosen people, the Quechua -speaking "cosmic race." This messianic movement seeks to cleanse Peru...The Quechua -speaking top echelon also provided a link with the Indian masses whom Guzman hoped to politicize. At the same time, however, his
Zeichner, Joshua A; Wong, Vicky; Linkner, Rita V; Haddican, Madelaine
2013-03-01
Combination therapy using medications with complementary mechanisms of action is the standard of care in treating acne. We report results of a clinical trial evaluating the use of a fixed-dose tretinoin 0.025%/clindamycin phosphate 1.2% (T/CP) gel in combination with a benzoyl peroxide 6% foaming cloth compared with T/CP alone for facial acne. At week 12, the combination therapy group showed a trend toward greater efficacy compared with T/CP alone. There was a high success rate observed in the study, which may be attributable to the large percentage of adult female acne patients enrolled. Cutaneous adverse events were not statistically different in using combination therapy compared with T/CP alone.
Design, fabrication and acceptance testing of a zero gravity whole body shower
NASA Technical Reports Server (NTRS)
Schumacher, E. A.; Lenda, J. A.
1974-01-01
Recent research and development programs have established the ability of the zero gravity whole body shower to maintain a comfortable environment in which the crewman can safely cleanse and dry the body. The purpose of this program was to further advance the technology of whole body bathing and to demonstrate technological readiness including in-flight maintenance by component replacement for flight applications. Three task efforts of this program are discussed. Conceptual designs and system tradeoffs were accomplished in task 1. Task 2 involved the formulation of preliminary and final designs for the shower, while task 3 included the fabrication and test of the shower assembly. Particular attention is paid to the evaluation and correction of test anomalies during the final phase of the program.
Grove, G L; Zerweck, C R; Heilman, J M; Pyrek, J D
2001-12-01
Hand-cleansing products that are milder to the skin of health care personnel are being developed, but the available methodologies to appropriately evaluate these products and quantify differences are not generally being applied in well-controlled studies. Two randomized, blinded, bilateral comparison studies evaluated skin condition during use of 2 antiseptic hand preparation products: a new 1% chlorhexidine gluconate (CHG)/61% wt/wt ethanol antiseptic hand preparation in a unique emollient system for waterless/brushless application and a conventional 4% CHG antimicrobial product that is applied with water and a scrub brush. Trained technicians applied treatments 6 times (for a surgical scrub study) or 24 times (for a personnel handwash study) daily to the hands of healthy volunteers during 5 days of controlled washing. An expert grader evaluated skin for dryness, erythema, and roughness. Subjects completed a self-assessment questionnaire on skin condition. Transepidermal water loss was measured by an evaporimeter, and the skin surface hydration level was measured by an electrical conductance meter. Fifty-eight subjects were enrolled in the 2 studies and received both treatments. In general, skin treated with the waterless CHG/ethanol product scored significantly (P <.004) better on evaluations of visual dryness and erythema and showed greater improvement in the level of hydration (P <.003). In the health care personnel handwash study, transepidermal water loss was less than that for skin treated with the conventional CHG product (P <.002). Subject assessments showed similar results (total score, P <.007). All 3 approaches of expert grader evaluation, subject assessment, and instrumentation were in concordance, demonstrating that the waterless CHG/ethanol product was gentler to skin than the conventional CHG product.
Conservation of water for washing beef heads at harvest
USDA-ARS?s Scientific Manuscript database
The objective of this research was to develop methods to conserve water necessary to cleanse beef heads prior to USDA–FSIS inspection. This was to be accomplished by establishing a baseline for the minimum amount of water necessary to adequately wash a head and application of image analysis to provi...
How to Support the Opposition in Syria: New Models for Understanding Syria
2014-01-01
cleansing ; contin- ued instability and loss of life caused by terror- ist organizations with local, regional or even global ambitions; or worsening...Administration before him, President Obama has exercised caution, initially determining that the safest course of action, and the most palatable to the
Phytoremediation is the use of plants to cleanse soil and water contaminated with organic or inorganic pollutants. This promising new field of research can be used for in situ clean up of large volumes and expansive areas of contaminated soils or waters, including ground water. ...
ERIC Educational Resources Information Center
Bader, Michael J.
2006-01-01
Patriotism can be a force for good or evil. American patriotism helped vanquish fascism; German patriotism helped create and sustain it. Wars of national liberation depend on patriotic fervor to oppose colonial rule; unfortunately, ethnic cleansing draws on this same fervor. Appeals to the transcendent value of the nation-state can be progressive…
21 CFR 524.1484c - Neomycin, isoflupredone, and tetracaine ointment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1484c Neomycin, isoflupredone, and tetracaine ointment. (a) Specifications. The.... When used on the skin or mucous membranes, the affected area should be cleansed, and a small amount of...
Dermatitis neglecta: a challenging diagnosis in psychodermatology.
Lopes, Sofia; Vide, Júlia; Antunes, Isabel; Azevedo, Filomena
2018-06-01
Dermatitis neglecta is a condition affecting the skin caused by a lack of hygiene. It may be related to psychiatric and neurological disturbances. The appearance of skin lesions results from neglect, which helps distinguish this condition from other similar clinical entities. Resolution of the lesions with adequate cleansing aids a definitive diagnosis.
21 CFR 200.50 - Ophthalmic preparations and dispensers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... intended for ophthalmic use, including preparations for cleansing the eyes, should be sterile. It is... use in the eye. (2) The Food and Drug Administration concludes that all such preparations, if they are... applicable to ophthalmic preparations that are regulated as medical devices. (3) The containers of ophthalmic...
Child Protagonists: The "Anne Franks" of Today
ERIC Educational Resources Information Center
Klein, Ana Maria
2003-01-01
The literary works surveyed here were written by authors who, as children, witnessed apartheid, holocaust, imprisonment, escape, genocide, ethnic cleansing, and other horrors that marked their lives. In each case, the selected texts are rendered as diaries or as first-person narratives describing disturbing situations which are resolved either…
Thermal Injury in the Pregnant Patient
1985-09-01
debrided, cleansed with a standard sented herein. Nineteen previously reported in- surgical detergent and treated in general by the stances are also...hyponatremia 0.983 30* 27 25 92.0 85.5 Gasoline fire - - Anuria, vaginal bleeding 0.987 *From the study done by Taylor and co-workers (8) in 1976. No
Code of Federal Regulations, 2011 CFR
2011-04-01
... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY... approximated skin edges of wounds from surgical incisions, including punctures from minimally invasive surgery, and simple, thoroughly cleansed, trauma-induced lacerations. It may be used in conjunction with, but...
Wiegand, C; Abel, M; Ruth, P; Hipler, U C
2011-11-01
A comprehensive in vitro approach was used to assess the effects of superabsorbent polymer (SAP) containing wound dressings in treatment of non-healing wounds. A slight negative effect on HaCaT cells was noted in vitro which is most likely due to the Ca(2+) deprivation of the medium by binding to the SAP. It could be shown that SAP wound dressings are able to bind considerable amounts of elastase reducing enzyme activity significantly. Furthermore, SAP's inhibit the formation of free radicals. The SAP-containing wound dressings tested also exhibited a significant to strong antimicrobial activity effectively impeding the growth of gram-negative and gram-positive bacteria as well as yeasts. In conclusion, in vitro data confirm the positive effect of SAP wound dressings observed in vivo and suggest that they should be specifically useful for wound cleansing.
Health-hazard evaluation report HETA 85-441-1765, New Boston Coke Corporation, New Boston, Ohio
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Malley, M.A.
1986-12-01
In response to a request from the Industrial Commission of Ohio, worker complaints of skin disease at the New Boston Coke Corporation, New Boston, Ohio were investigated. The request was based on seven reports of dermatitis thought to be associated with steam exposure during coke quenching. Quench water had a pH of 8.85 and contained phenol, ammonia, calcium-oxide, and suspended particulates (82% organic compounds); no irritant threshold levels were found for these compounds. Skin tests in rabbits showed a minimal irritant capacity for quench water. Medical records did not reveal the origin of dermatitis. Active skin lesions were characterized asmore » nummular eczema or atopic dermatitis, which were not thought to be of occupational origin. The author concludes that coke-quenching steam does not pose a skin hazard, but certain work activities may aggravate existing skin conditions. Recommendations include elimination of abrasive cleansing agents, use of skin moisturizers after washing, and prompt medical evaluation of skin complaints.« less
Pharmaceutical evaluation of different shampoo brands in local Saudi market.
AlQuadeib, Bushra T; Eltahir, Eram K D; Banafa, Rana A; Al-Hadhairi, Lama A
2018-01-01
Shampooing is the most common form of hair treatment. Shampoos are primarily products aimed at cleansing the hair and scalp. There are many brands of shampoos in Saudi Arabia, available from different sources, locally and imported from other countries. This study aims to investigate whether such brands comply with the Saudi standard specifications for shampoos, issued by the National Center for Specifications and Standards, and to what extent these specifications are applied. Six shampoo brands were randomly collected from Riyadh market (Pantene®, Sunsilk®, Herbal essences®, Garnier Ultra Doux®, Syoss® and L'Oreal Elvive®). The selected shampoos were evaluated according to their physicochemical properties, including organoleptic characterization, pH measurement, percentage of solid content, rheological measurements, dirt dispersion level, foaming ability and foam stability, and surface tension. All shampoos had a good percentage of solids, excellent foam formation with stable foam and a highly viscous nature. Regarding the pH measurement, all shampoo samples were within the specified range with good wetting ability.
Development of clay liquid detergent for Islamic cleansing and the stability study.
Angkatavanich, J; Dahlan, W; Nimmannit, U; Sriprasert, V; Sulongkood, N
2009-04-01
Clay liquid detergents (CLDs) were developed for cleansing religiously-prohibited dirt ('najis') according to Islamic law. Four types of clay were selected: marl, kaolin, bentonite and veegum. After product development trials, five CLD formulations with varying combinations of clays were qualified for stability testing. Three exaggerated temperature conditions were considered: 4 degrees C for 24 h, 50 degrees C for 7 days, and 40 degrees C for 1 month. The CLDs were also evaluated at 30, 60 and 90 days after production, while being stored at room temperature (RT30, RT60 and RT90). Physical and chemical characteristics including pH, colour, viscosity, surface tension, foam tests and sensory liking scores were evaluated. Our results showed that the kaolin-based formula, F2, had an optimal pH (closest to skin pH) of 5.08. The other formulas ranged from pH 6 to 8. Colour shades of the CLDs ranged from white, to creamy white, to mildly greenish-white. The foaming properties of the CLDs, the means +/- SD of foam heights at 0 and 5 min, using the Ross-Miles test, were 19.13 +/- 0.25 to 20.88 +/- 0.45 cm at RT90 and were comparable with those of commercial detergents. Foam stability of all CLDs was high, as shown from the foam heights between 0 and 5 min being not significantly different (P > 0.05). The surface tensions, means +/- SD, of CLD solutions were between 27.94 +/- 0.08 and 28.72 +/- 0.04 mN m(-1), which were slightly better than the surface tension of 29.08 +/- 0.04 mN m(-1) for sodium lauryl sulphate. There was a weak negative relationship between surface activity and foam height, based on the pooled data of the CLDs (R(2) = 0.209, P < 0.01). The viscosity of four CLDs ranged from 16 317 to 49 036 mPa s. In conclusion, CLDs can be formulated with good stability. F2 (kaolin-based, with a white, creamy texture) was the best CLD formula. It had the highest surface activity, moderate lathering and pleasant physical appearance.
Hong, Gil-Sun; Park, Seong Ho; Kim, Bohyun; Lee, Ju Hee; Kim, Jin Cheon; Yu, Chang Sik; Baek, Seunghee; Lee, Jong Seok; Kim, Hyun Jin
2015-04-01
The purpose of this study was to determine whether the occurrence of numerous colonic bubbles during CT colonography (CTC) performed with polyethylene glycol cleansing and oral iohexol fecal/fluid tagging could be prevented by use of simethicone. Adults with suspected colonic neoplasia who had been randomly assigned to control and simethicone intervention groups underwent CTC after cleansing with 4 L of polyethylene glycol, tagging with 50 mL of 350 mg I/mL oral iohexol, and without (control) or with (intervention) oral administration of 200 mg of simethicone. Colonic segments in the control and intervention groups were evaluated for amount of colonic bubbles during CTC. A 6-point grading system was used in which 0 indicated no bubbles and 5 indicated that more than three fourths of the air-distended mucosa was covered with bubbles. The primary endpoint was a per-patient colonic bubble grade, derived as an average of the segmental grades. Eighty adults with suspected colonic neoplasia were randomly assigned to the control (40 patients) and simethicone intervention (40 patients) groups. A total of 659 colonic segments in the control group and 689 segments in the intervention group were evaluated for amount of colonic bubbles during CTC. The per-patient colonic bubble score was significantly lower in the simethicone intervention group than in the control group. The mean score was 0.0±0.1 (SD) versus 1.2±0.8 (p<0.001; 95% CI for the mean difference, -1.4 to -1.0). In the intervention group, 673 (97.7%) segments were grade 0, and 16 (2.3%) were grade 1. In contrast, in the control group, 226 (34.3%) segments were grade 0; 173 (26.3%), grade 1; 175 (26.6%), grade 2; 45 (6.8%), grade 3; 23 (3.5%), grade 4; and 17 (2.6%), grade 5. The colonic bubbles associated with fecal/fluid tagging with iohexol can be successfully prevented by adding simethicone to the colonic preparation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall, L.C.; Daniels, J.I.
1990-11-01
Dermal disease is significant cause of morbidity among soldiers in a combat setting. For example, among American combat troops in Vietnam, disability from skin disease was one of the single most important medical causes of man-days lost from combat. Currently, the US Army makes shower or bath facilities available to soldiers in the field on a weekly basis. US Army after-action reports and anecdotal descriptions from the field indicate that this may not be an optimal regimen for the maintenance of personal hygiene, especially with respect to diseases of the skin. Determination of the optimal frequency of showering of bathingmore » for soldiers in a combat setting is complicated by the fact of showering or bathing for soldiers in a combat setting is complicated by the fact that soldiers in the US Army may be involved in field exercise or combat in many different areas of the world with a variety of climatic conditions. Although certain aspects of the role of environmental factors in the incidence and severity of dermal disease have been documented, the role of hygiene in the potential mitigation of these effects has not been evaluated. The present project entails a comprehensive review and analysis of available literature in order to determine the health impact of shower/bath frequency for soldiers in a combat setting. An integral component of this work is an evaluation of the impact of climate, and microclimate produced by clothing, on the type, frequency, and severity of skin disease. There is relatively large body of information concerning the effectiveness of antimicrobial soaps in minimizing the incidence and severity of dermal disease. This data will be evaluated to determine whether use of these soaps, or an increase in the use of cleansing agents in general, will result in a decrease in the severity and incidence of diseases of the skin for soldiers in the field. 32 refs., 2 figs., 1 tab.« less
A review of the therapeutic effects of using miswak (Salvadora Persica) on oral health
Haque, Mohammad M.; Alsareii, Saeed A.
2015-01-01
Miswak is a traditional chewing stick prepared from the roots, twigs, and stem of Salvadora persica and has been used as a natural method for tooth cleaning in many parts of the world for thousands of years. A number of scientific studies have demonstrated that the miswak (Salvadora persica) possesses antibacterial, anti-fungal, anti-viral, anti-cariogenic, and anti-plaque properties. Several studies have also claimed that miswak has anti-oxidant, analgesic, and anti-inflammatory effects. The use of a miswak has an immediate effect on the composition of saliva. Several clinical studies have confirmed that the mechanical and chemical cleansing efficacy of miswak chewing sticks are equal and at times greater than that of the toothbrush. The present article provides a review of the various therapeutic effects of Salvadora persica on oral health, which will help to elucidate the significance and importance of this indigenous oral hygiene tool. PMID:25935172
Guerra, V G; Gonçalves, J A S; Coury, J R
2009-01-15
Venturi scrubbers are widely utilized in gas cleaning. The cleansing elements in these scrubbers are droplets formed from the atomization of a liquid into a dust-laden gas. In industrial scrubbers, this liquid is injected through several orifices so that the cloud of droplets can be evenly distributed throughout the duct. The interaction between droplets when injected through many orifices, where opposite clouds of atomized liquid can reach each other, is to be expected. This work presents experimental measurements of droplet size measured in situ and the evidence of cloud interaction within a Venturi scrubber operating with multi-orifice jet injection. The influence of gas velocity, liquid flow rate and droplet size variation in the axial position after the point of the injection of the liquid were also evaluated for the different injection configurations. The experimental results showed that an increase in the liquid flow rate generated greater interaction between jets. The number of orifices had a significant influence on droplet size. In general, the increase in the velocity of the liquid jet and in the gas velocity favored the atomization process by reducing the size of the droplets.
Efficacy of antioxidants in human hair.
Fernández, Estibalitz; Martínez-Teipel, Blanca; Armengol, Ricard; Barba, Clara; Coderch, Luisa
2012-12-05
Hair is exposed every day to a range of harmful effects such as sunlight, pollution, cosmetic treatments, grooming practices and cleansing. The UV components of sunlight damage human hair, causing fibre degradation. UV-B attacks the melanin pigments and the protein fractions (keratin) of hair and UV-A produces free radical/reactive oxygen species (ROS) through the interaction of endogenous photosensitizers. Hair was dyed and the efficacy of two antioxidant formulations was demonstrated after UV exposure by evaluating, surface morphology, protein and amino acid degradation, lipidic peroxidation, colour and shine changes and strength/relaxation properties. UV treatment resulted in an increase in protein and lipid degradation, changes in colour and shine and in adverse consequences for the mechanical properties. Natural antioxidants obtained from artichoke and rice applied to pretreated hair improved mechanical properties and preserved colour and shine of fibres, coating them and protecting them against UV. Furthermore, the lipidic peroxidation of the protein degradation caused by UV was reduced for some treated fibres, suggesting an improvement in fibre integrity. This was more marked in the case of the fibres treated using the artichoke extract, whereas the rice extract was better preserving shine and colour of hair fibres. Copyright © 2012 Elsevier B.V. All rights reserved.
Wu, Qingyu; Shigaki, Toshiro; Williams, Kimberly A; Han, Jeung-Sul; Kim, Chang Kil; Hirschi, Kendal D; Park, Sunghun
2011-01-15
Phytoremediation is a cost-effective and minimally invasive technology to cleanse soils contaminated with heavy metals. However, few plant species are suitable for phytoremediation of metals such as cadmium (Cd). Genetic engineering offers a powerful tool to generate plants that can hyperaccumulate Cd. An Arabidopsis CAX1 mutant (CAXcd), which confers enhanced Cd transport in yeast, was ectopically expressed in petunia to evaluate whether the CAXcd expression would enhance Cd tolerance and accumulation in planta. The CAXcd-expressing petunia plants showed significantly greater Cd tolerance and accumulation than the controls. After being treated with either 50 or 100μM CdCl(2) for 6 weeks, the CAXcd-expressing plants showed more vigorous growth compared with controls, and the transgenic plants accumulated significantly more Cd (up to 2.5-fold) than controls. Moreover, the accumulation of Cd did not affect the development and morphology of the CAXcd-expressing petunia plants until the flowering and ultimately the maturing of seeds. Therefore, petunia has the potential to serve as a model species for developing herbaceous, ornamental plants for phytoremediation. Copyright © 2010 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Smith, James F., III; Blank, Joseph A.
2003-03-01
An approach is being explored that involves embedding a fuzzy logic based resource manager in an electronic game environment. Game agents can function under their own autonomous logic or human control. This approach automates the data mining problem. The game automatically creates a cleansed database reflecting the domain expert's knowledge, it calls a data mining function, a genetic algorithm, for data mining of the data base as required and allows easy evaluation of the information extracted. The co-evolutionary fitness functions, chromosomes and stopping criteria for ending the game are discussed. Genetic algorithm and genetic program based data mining procedures are discussed that automatically discover new fuzzy rules and strategies. The strategy tree concept and its relationship to co-evolutionary data mining are examined as well as the associated phase space representation of fuzzy concepts. The overlap of fuzzy concepts in phase space reduces the effective strategies available to adversaries. Co-evolutionary data mining alters the geometric properties of the overlap region known as the admissible region of phase space significantly enhancing the performance of the resource manager. Procedures for validation of the information data mined are discussed and significant experimental results provided.
Cleansed Data from Transportation Studies and Surveys | Transportation
and search for transportation studies and surveys by name, date, state, agency, survey records, and browse and download all the drive cycle data from different studies, see drive cycle data. Study/Survey Name Year State(s)/Region Data Collection Agency Survey Records Vehicles with Installed GPS
40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...
40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...
40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...
40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...
40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...
Earl Finbar Murphy
1976-01-01
It is a truism for the living environment that life cannot sustain itself on its own wastes. The environment has self-cleansing properties which permit the dilution, reconstitution, and reuse by other natural processes of waste. These self-operative properties are what produces the flow of dynamic change that renews what is renewable within nature. The forces for...
A Review and Analysis of the Ayurvedic Institute's Ayurvedic Studies Program.
ERIC Educational Resources Information Center
Rogers, Curtis R.
The Ayurvedic Institute, which has been licensed as a private institution of higher education in New Mexico since 1994, offers training in the traditional therapy of East Indian Ayurveda, which includes the use of herbs, nutrition, panchakarma cleansing, and accupressure massage. The institute also offers training in the related disciplines of…
School Voices: Challenges Facing Education Systems after Identity-Based Conflicts
ERIC Educational Resources Information Center
Weinstein, Harvey M.; Freedman, Sarah Warshauer; Hughson, Holly
2007-01-01
We describe our research on the role of education in the social reconstruction of countries after mass conflict. Our studies focus on the voices of those least heard in the discourse--teachers, students, administrators and parents. We examine schools in four societies that experienced profound violence, ethnic cleansing and genocide during the…
Education in a Recovering Nation: Renewing Special Education in Kosovo
ERIC Educational Resources Information Center
Bartlett, Brendan; Power, Des; Blatch, Peter
2004-01-01
"The inexhaustible problem of the Balkans" (Tuchman, 1962, p. ix). Kosovo, technically still a province of Serbia, was devastated by the wars of the 1990s, culminating in 1999 in the flight of refugees to neighboring countries, whether voluntarily or through deliberate "ethnic cleansing", the NATO bombing raids; the withdrawal…
Velocity-based analysis of sediment incipient deposition in rigid boundary open channels.
Aksoy, Hafzullah; Safari, Mir Jafar Sadegh; Unal, Necati Erdem; Mohammadi, Mirali
2017-11-01
Drainage systems must be designed in a way to minimize undesired problems such as decrease in hydraulic capacity of the channel, blockage and transport of pollutants due to deposition of sediment. Channel design considering self-cleansing criteria are used to solve the sedimentation problem. Incipient deposition is one of the non-deposition self-cleansing design criteria that can be used as a conservative method for channel design. Experimental studies have been carried out in five different cross-section channels, namely trapezoidal, rectangular, circular, U-shape and V-bottom. Experiments were performed in a tilting flume using four different sizes of sands as sediment in nine different channel bed slopes. Two well-known methods, namely the Novak & Nalluri and Yang methods are considered for the analysis of sediment motion. Equations developed using experimental data are found to be in agreement with the literature. It is concluded that the design velocity depends on the shape of the channel cross-section. Rectangular and V-bottom channels need lower and higher incipient deposition velocities, respectively, in comparison with other channels.
Contamination of blood cultures during venepuncture: fact or myth?
Shahar, E.; Wohl-Gottesman, B. S.; Shenkman, L.
1990-01-01
Contamination of blood cultures is believed to occur mainly during the venepuncture procedure. Consequently, meticulous preparation of the venepuncture site is widely recommended. To determine whether the contamination rate is indeed affected by the quality of the antiseptic procedure at the venepuncture site, 181 paired cultures were collected from 176 patients during a 6-month period after either strict antiseptic cleansing of skin with alcohol followed by povidone-iodine, or after brief disinfection with alcohol alone. The contamination rate was not influenced by the antiseptic procedure, and corresponded to the accepted percentage reported in most other studies. Eight false positive cultures (4.4%) were obtained after strict antisepsis of the skin and 6 (3.3%) after short simple cleansing with alcohol (P = 0.39). Our results suggest that contamination of blood cultures may not be related to the venepuncture procedure--regardless of the antiseptic technique used--but may be due to later stages of laboratory handling and processing of the specimens. Review of the literature has provided further indirect evidence to support this conclusion. PMID:2084653
“SHANKHA PRAKSHALANA” (GASTROINTESTINAL LAVAGE) IN HEALTH AND DISEASE
Singh, S. N.; Jaiswal, V.; Maurya, S. P.
1988-01-01
Shankha Prakshalana is an easy and effective technique for cleansing the gastrointestinal canal, thereby removing all the autointoxicants present in the alimentary canal. Moreover, it is a very economical procedure which can be performed by the patients at his own residence. The role of Shankha Prakshalana from our own experience is very effective in overcoming the irritable bowel syndrome. Shankha Prakshalana may also be given to the patients of anxiety neurosis with satisfactory results. Its role in the treatment of renal disorder is encouraging in early cases only. However, in the second and third degree chronic renal failure cases its role is yet to be established and needs further investigation. Similarly, in the case of thyrotoxicosis no conclusive evidence could be observed due to very limited number of cases. PMID:22557607
Evaluation of various agro-wastes for traditional black soap production.
Taiwo, O E; Osinowo, F A
2001-08-01
The agricultural wastes, cocoa-pod husks, palm-bunch waste, sorghum chaff and groundnut shells, which are normally thrown away have been used in the production of black soap. Unlike other soaps which are made from oils and chemicals, black soap is made from oils and agro-wastes ashes. Chemical analysis indicated that the liquid extract from the ashes of the different agro-wastes used contained various amounts of potassium and sodium compounds. The most common ingredient in the agro-wastes was potassium carbonate. The amount of potassium carbonate was 56.73 +/- 0.16% in cocoa-pod ash, 43.15 +/- 0.13% in palm-bunch ash, 16.65 +/- 0.05% in groundnut shell ash and 12.40 +/- 0.08% in sorghum chaff ash. Soaps made from the agro-wastes ashes had excellent solubility, consistency, cleansing and lathering abilities.
Walter, Benjamin Michael; Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan
2016-06-21
In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective of this study was to assess the function of an automated text messaging (short message service, SMS)-supported colonoscopy preparation starting 4 days before colonoscopy appointment. After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging-provided information assessed by a questionnaire. Web-based SMS text messaging-supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging-based information was high. Using SMS for colonoscopy preparation with 4 days' guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation.
Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan
2016-01-01
Background In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective Objective of this study was to assess the function of an automated text messaging (short message service, SMS)–supported colonoscopy preparation starting 4 days before colonoscopy appointment. Methods After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging–provided information assessed by a questionnaire. Results Web-based SMS text messaging–supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging–based information was high. Conclusions Using SMS for colonoscopy preparation with 4 days’ guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation. PMID:27329204
Vieira, Ana Paula Coelho; Senna, Plínio Mendes; Silva, Wander José da; Del Bel Cury, Altair Antoninha
2010-01-01
This study evaluated the long-term efficacy of denture cleansers against Candida spp. biofilm recolonization on liner surface. Specimens were fabricated of a poly(methyl methacrylate)-based denture liner and had their surface roughness evaluated at baseline and after cleansing treatments. C. albicans or C. glabrata biofilms were formed on liner surface for 48 h, and then the specimens were randomly assigned to one of cleaning treatments: two alkaline peroxides (soaking for 3 or 15 min), 0.5% sodium hypochlorite (10 min) or distilled water (control; 15 min). After the treatments, the specimens were sonicated to disrupt the biofilm, and residual cells were counted (cell/mL). Long-term effectiveness of the cleaning processes was determined by submitting a set of cleaned specimens to biofilm growth conditions for 48 h followed by estimation of cell counts. The topography of specimens after cleaning treatments was analyzed by SEM. Data were analyzed by ANOVA and Tukey's test (α; = 0.05). Results of cell count estimation showed significant differences in cleanliness among the treatments (p < 0.001), and it could be observed by SEM. However, no significant difference (p > 0.05) was observed among the Candida species regarding the recolonization condition. Alkaline denture cleansers showed similar cleaning performance and both differed from the control (p < 0.001). Sodium hypochlorite was the only treatment that removed biofilm efficiently, since no viable cells were found after its use. In conclusion, alkaline peroxide denture cleansers were not effective in removing Candida spp. biofilm from denture liner surfaces and preventing biofilm recolonization.
Harvey, Carol
2005-01-01
Wound healing in orthopaedic care is affected by the causes of the wound, as well as concomitant therapies used to repair musculoskeletal structures. Promoting the health of the host and creating an environment to foster natural healing processes is essential for helping to restore skin integrity. Normal wound healing physiologic processes, factors affecting wound healing, wound classification systems, unique characteristics of orthopaedic wounds, wound contamination and drainage characteristics, and potential complications are important to understand in anticipation of patient needs. Accurate wound assessment and knowledge of nursing implications with specific wound care measures (cleansing, debridement, and dressings) is important for quality care. New technologies are enhancing traditional wound care measures with goals of effective comfortable wound care to promote restoration of skin integrity.
de Leone, Annalisa; Tamayo, Darina; Fiori, Giancarla; Ravizza, Davide; Trovato, Cristina; De Roberto, Giuseppe; Fazzini, Linda; Dal Fante, Marco; Crosta, Cristiano
2013-01-01
AIM: To evaluate the efficacy, tolerability, acceptability and feasibility of bisacodyl plus low volume polyethyleneglycol-citrate-simeticone (2-L PEG-CS) taken the same day as compared with conventional split-dose 4-L PEG for late morning colonoscopy. METHODS: Randomised, observer-blind, parallel group, comparative trial carried out in 2 centres. Out patients of both sexes, aged between 18 and 85 years, undergoing colonoscopy for diagnostic investigation, colorectal cancer screening or follow-up were eligible. The PEG-CS group received 3 bisacodyl tablets (4 tablets for patients with constipation) at bedtime and 2-L PEG-CS in the morning starting 5 h before colonoscopy. The control group received a conventional 4-L PEG formulation given as split regimen; the morning dose was taken with the same schedule of the low volume preparation. The Ottawa Bowel Preparation Scale (OBPS) score was used as the main outcome measure. RESULTS: A total of 164 subjects were enrolled and 154 completed the study; 78 in the PEG-CS group and 76 in the split 4-L PEG group. The two groups were comparable at baseline. The OBPS score in the PEG-CS group (3.09 ± 2.40) and in the PEG group (2.39 ± 2.55) were equivalent (difference +0.70; 95%CI: -0.09-1.48). This was confirmed by the rate of successful bowel cleansing in the PEG-CS group (89.7%) and in the PEG group (92.1%) (difference -2.4%; 95%CI: -11.40- 6.70). PEG-CS was superior in terms of mucosa visibility compared to PEG (85.7% vs 72.4%, P = 0.042). There were no significant differences in caecum intubation rate, time to reach the caecum and withdrawal time between the two groups. The adenoma detection rate was similar (PEG-CS 43.6% vs PEG 44.7%). No serious adverse events occurred. No difference was found in tolerability of the bowel preparations. Compliance was equal in both groups: more than 90% of subjects drunk the whole solution. Willingness to repeat the same bowel preparations was about 90% for both regimes. CONCLUSION: Same-day PEG-CS is feasible, effective as split-dose 4-L PEG for late morning colonoscopy and does not interfere with work and daily activities the day before colonoscopy. PMID:24044042
de Leone, Annalisa; Tamayo, Darina; Fiori, Giancarla; Ravizza, Davide; Trovato, Cristina; De Roberto, Giuseppe; Fazzini, Linda; Dal Fante, Marco; Crosta, Cristiano
2013-09-16
To evaluate the efficacy, tolerability, acceptability and feasibility of bisacodyl plus low volume polyethyleneglycol-citrate-simeticone (2-L PEG-CS) taken the same day as compared with conventional split-dose 4-L PEG for late morning colonoscopy. Randomised, observer-blind, parallel group, comparative trial carried out in 2 centres. Out patients of both sexes, aged between 18 and 85 years, undergoing colonoscopy for diagnostic investigation, colorectal cancer screening or follow-up were eligible. The PEG-CS group received 3 bisacodyl tablets (4 tablets for patients with constipation) at bedtime and 2-L PEG-CS in the morning starting 5 h before colonoscopy. The control group received a conventional 4-L PEG formulation given as split regimen; the morning dose was taken with the same schedule of the low volume preparation. The Ottawa Bowel Preparation Scale (OBPS) score was used as the main outcome measure. A total of 164 subjects were enrolled and 154 completed the study; 78 in the PEG-CS group and 76 in the split 4-L PEG group. The two groups were comparable at baseline. The OBPS score in the PEG-CS group (3.09 ± 2.40) and in the PEG group (2.39 ± 2.55) were equivalent (difference +0.70; 95%CI: -0.09-1.48). This was confirmed by the rate of successful bowel cleansing in the PEG-CS group (89.7%) and in the PEG group (92.1%) (difference -2.4%; 95%CI: -11.40- 6.70). PEG-CS was superior in terms of mucosa visibility compared to PEG (85.7% vs 72.4%, P = 0.042). There were no significant differences in caecum intubation rate, time to reach the caecum and withdrawal time between the two groups. The adenoma detection rate was similar (PEG-CS 43.6% vs PEG 44.7%). No serious adverse events occurred. No difference was found in tolerability of the bowel preparations. Compliance was equal in both groups: more than 90% of subjects drunk the whole solution. Willingness to repeat the same bowel preparations was about 90% for both regimes. Same-day PEG-CS is feasible, effective as split-dose 4-L PEG for late morning colonoscopy and does not interfere with work and daily activities the day before colonoscopy.
Cleansing the Superdome: The Paradox of Purity and Post-Katrina Guilt
ERIC Educational Resources Information Center
Grano, Daniel A.; Zagacki, Kenneth S.
2011-01-01
The reopening of the New Orleans Superdome after Hurricane Katrina on Monday Night Football dramatized problematic rhetorical, visual, and spatial norms of purification rituals bound up in what Burke calls the paradox of purity. Hurricane Katrina was significant as a visually traumatic event in large part because it signified the ghetto as a…
The stream subsurface: nitrogen cycling and the cleansing function of hyporheic zones
Rhonda Mazza; Steve Wondzell; Jay Zarnetske
2014-01-01
Nitrogen is an element essential to plant growth and ecosystem productivity. Excess nitrogen, however, is a common water pollutant. It can lead to algal blooms that deplete the water's dissolved oxygen, creating "dead zones" devoid of fish and aquatic insects.Previous research showed that the subsurface area of a stream, known as the hyporheic...
U.S. EPA, Pesticide Product Label, BARRAGE INDUSTRIAL STRENGTH BOWL CLEANSE, 08/20/1974
2011-04-14
... VIJI") "'f ';1,',111"1 nll!1) III(, h,,, p"J"'ilrl .l 1""1 l'I,lul, e,f' ','IVIC" !, t,;~, iif.',lJ.-li(' f~"~; l'_,I;J~e [._.If 1:u:..kdl.1) .trlc1 t'n·JJrl..ifHTH;lltd~ nl !Ird' ndl1<.~' V,'ln ...
The paper summarizes the results of a 2-year field test to assess the performance of a specially modified commercial phosphoric acid 200 kW fuel cell power plant to recover energy from anaerobic digester gas (ADG) which has been cleansed of contaminants (sulfur and halide compoun...
USN/USMC Commander’s Quick Reference Handbook for Legal Issues, 2007
2007-01-01
remain silent or asks for a lawyer, you MUST NOT ask any more questions. PRIOR QUESTIONING WITHOUT RIGHTS WARNING: Provide " Cleansing Warning...punishments. CA approves any pre-trial agreement. CA takes action on findings & sentence after clemency period has expired . GENERAL COURT-MARTIAL...findings and sentence after clemency period has expired
USN/USMC Commander’s Quick Reference Handbook for Legal Issues
2008-01-01
34 cleansing warning" if someone has previously questioned the member and did not provide rights warnings. (1) Advise the member that the prior...punishments. CA approves any pre-trial agreement. CA takes action on findings & sentence after clemency period has expired . GENERAL...agreement. GCMCA takes action on findings and sentence after clemency period has expired
Remarks of Kevin Gover, Assistant Secretary-Indian Affairs: Address to Tribal Leaders.
ERIC Educational Resources Information Center
Gover, Kevin
2000-01-01
Assistant Secretary Gover apologizes for the Bureau of Indian Affairs' (BIA) actions in the ethnic cleansing of American Indian tribes and the destruction of Indian cultures. He asserts the agency's moral responsibility of putting things right and proposes that a healing process begin and that the BIA work to reinvent itself as an instrument of…
NASA Technical Reports Server (NTRS)
Proctor, B. W.; Reysa, R. P.; Russell, D. J.
1975-01-01
Technical data collected for the food management and personal hygiene appliances considered for the shuttle orbiter are presented as well as plotted and tabulated trade study results for each appliance. Food storage, food operation, galley cleanup, waste collection/transfer, body cleansing, and personal grooming were analyzed.
1983-07-01
Bathing an infant 22. Bed bath (complete - adult) 23. Back bath (partial - legs, back, abdomen) 24. Bed shampoo (female) 25. Catheter care ( cleansing ...Stool testing 126. Applying condum catheter 127. Removal chest tubes 128. Assisting with vaginal /pelvic examination INDIRECT 1. Admission of a patient
Post Anesthesia Care Unit Patient Classification System: The Direct Care Nursing Time Component
1991-07-18
Removal 1304 Enema - Cleansing 1305 Enema - Retention 1306 Colostomy - Irrigation 1307 Colostomy - Dressing Change 1308 Lavage 1309 Paracentesis 1310...Curettage 1910 Vaginal /Pelvic Ex,.iiination 1911 Urinary Bladder Training 1912 Condom Catheter Application 1913 Peritoneal Dialysis - Initiation 1914...Hypothermia/Hyperthermia Treatment 2101 Oral Medication 2102 Intramuscular Medication 2103 Subcutaneous Medication 2104 Suppository, Rectal/ Vaginal
USSR and Eastern Europe Scientific Abstracts Physics and Mathematics No. 30
1976-12-01
polyethylene target is cleansed of protons in a plexiglas filter, after passing through which the protons andfT-mesons have different momenta, so that they...associated with nonmonochromaticity of the source. 1/1 USSR UDC 535.33:621.375.8;535:530.182;778.38 VANIN, V. A. and VAGIN , L. N. COPYING OF HOLOGRAMS
Maletis, Gregory B; Chen, Jason; Inacio, Maria C S; Love, Rebecca M; Funahashi, Tadashi T
2017-07-01
The optimal graft for anterior cruciate ligament reconstruction (ACLR) remains controversial. To compare the risk of aseptic revision between bone-patellar tendon-bone (BPTB) autografts, hamstring autografts, and soft tissue allografts. Cohort study; Level of evidence, 2. Prospectively collected ACLR cases reconstructed with BPTB autografts, hamstring autografts, and soft tissue allografts were identified using the Kaiser Permanente ACLR Registry. Aseptic revision was the endpoint. The type of graft and allograft processing method (nonprocessed, <1.8-Mrad irradiation with and without chemical processing [Allowash or AlloTrue], ≥1.8-Mrad irradiation with and without chemical processing, and chemical processing alone [BioCleanse]) were the exposures evaluated. Analyses were adjusted for age, sex, and race. Kaplan-Meier curves and Cox proportional hazards models were employed. The cohort included 14,015 cases: there were 8924 (63.7%) male patients, there were 6397 (45.6%) white patients, 4557 (32.5%) ACLRs used BPTB autografts, 3751 ACLRs (26.8%) used soft tissue allografts, and 5707 (40.7%) ACLRs used hamstring autografts. The median age was 34.6 years for soft tissue allografts, 24.3 years for hamstring autografts, and 22.0 years for BPTB autografts. The crude nonadjusted revision rates were 85 (1.9%) in BPTB autograft cases, 132 (2.3%) in hamstring autograft cases, and 83 (2.2%) in soft tissue allograft cases. After adjusting for age, sex, and race, compared with hamstring autografts, a higher risk of revision was found with allografts with ≥1.8 Mrad without chemical processing after 2.5 years (hazard ratio [HR], 3.88; 95% CI, 1.48-10.12) and ≥1.8 Mrad with chemical processing after 1 year (HR, 3.43; 95% CI, 1.58-7.47) and with BioCleanse processed grafts at any time point (HR, 3.02; 95% CI, 1.40-6.50). Nonprocessed allografts and those irradiated with <1.8 Mrad with or without chemical processing were not found to have a different risk of revision compared with hamstring autografts. Compared with BPTB autografts, a higher risk of revision was seen with hamstring autografts (HR, 1.51; 95% CI, 1.15-1.99) and BioCleanse processed allografts (HR, 4.67; 95% CI, 2.15-10.16). Allografts irradiated with <1.8 Mrad with chemical processing (Allowash or AlloTrue) (HR, 2.19; 95% CI, 1.42-3.38) and without chemical processing (HR, 2.31; 95% CI, 1.40-3.82) had a higher risk of revision, as did allografts with ≥1.8 Mrad without chemical processing after 2 years (HR, 6.30; 95% CI, 3.18-12.48) and ≥1.8 Mrad with chemical processing (Allowash or AlloTrue) after 1 year (HR, 5.03; 95% CI, 2.30-11.00) compared with BPTB autografts. Nonprocessed allografts did not have a higher risk of revision compared with autografts. With the numbers available, direct comparisons between the specific allograft processing methods were not possible. When soft tissue allografts are used for ACLR, processing and time from surgery affect the risk of revision. Tissue processing has a significant effect on the risk of revision surgery, which is most profound with more highly processed grafts and increases with increasing follow-up time. Surgeons and patients need to be aware of the increased risks of revision with the various soft tissue allografts used for ACLR.
Seow-En, I; Seow-Choen, F
2016-07-01
The study aimed to determine whether Coca-Cola (Coke) Zero is a safe and effective solvent for polyethylene glycol (PEG). Between December 2013 and April 2014, 209 healthy adults (115 men, 95 women) scheduled for elective colonoscopy were randomized to use either Coke Zero (n = 100) or drinking water (n = 109) with PEG as bowel preparation. Each patient received two sachets of PEG to dissolve in 2 l of solvent, to be completed 6 h before colonoscopy. Serum electrolytes were measured before and after preparation. Bowel cleanliness and colonoscopy findings were recorded. Palatability of solution, adverse effects, time taken to complete and willingness to repeat the preparation were documented via questionnaire. Mean palatability scores in the Coke Zero group were significantly better compared with the control group (2.31 ± 0.61 vs 2.51 ± 0.63, P = 0.019), with a higher proportion willing to use the same preparation again (55% vs 43%). The mean time taken to complete the PEG + Coke Zero solution was significantly faster (74 ± 29 min vs 86 ± 31 min, P = 0.0035). The quality of bowel cleansing was also significantly better in the Coke Zero group (P = 0.0297). There was no difference in the frequency of adverse events (P = 0.759) or the polyp detection rate (32% vs 31.2%). Consumption of either preparation did not significantly affect electrolyte levels or hydration status. Coke Zero is a useful alternative solvent for PEG. It is well tolerated, more palatable, leads to quicker consumption of the bowel preparation and results in better quality cleansing. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.
Lorenzo-Zúñiga, Vicente; Moreno de Vega, Vicente; Marín, Ingrid; Barberá, Marta; Boix, Jaume
2015-07-01
Getting ready for a colonoscopy is difficult and involves many steps. Information given to patients is very important for adherence to treatment. We created a novel smart phone application (SPA) aimed to increase bowel preparation quality and patient satisfaction. We carried out a prospective, endoscopist-blinded, randomized, controlled trial. We enrolled 260 outpatient (58% female, age range 21-75 years) owners of a smartphone. Patients were allocated to two different protocols: instructions provided by SPA (SPA group; n = 108) or written instructions with visual aids (control group; n = 152). All procedures were carried out in the afternoon and patients received the same purgative regimen (2 L polyethylene glycol (PEG) solution plus ascorbic acid), in a full-dose same-day regimen. The study was designed to detect an improvement in quality of bowel preparation using the Harefield Cleansing Scale (HCS) scale. Effect of protocol on patient satisfaction was assessed with a specific questionnaire at the time of colonoscopy. Proportion of patients who obtained successful bowel preparation for colonoscopy (HCS A or B) was significantly higher in the SPA group than in the control group (100% vs 96.1%, respectively; P = 0.037). Mean global HCS scores were similar in both groups. Patient-reported tolerability and overall experience with the prescribed bowel preparation were significantly higher for the SPA group than for the control group. Successful cleansing and patient acceptability with the use of SPA were superior to written instructions in outpatients submitted for colonoscopy using 2 L PEG solution plus ascorbic acid. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.
Ultrasonic characterization of single drops of liquids
Sinha, Dipen N.
1998-01-01
Ultrasonic characterization of single drops of liquids. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-quality measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities.
The use of hydrodynamic vortex separators and screening systems to improve water quality.
Andoh, R Y G; Saul, A J
2003-01-01
The paper reviews the evolution of Hydrodynamic Vortex Separators (HDVS) in the context of application as high rate rotary flow separators for achieving water quality improvements to meet with regulatory requirements in Europe and North America. The types of HDVS and their application for the control of wet-weather discharges such as combined sewer overflows (CSOs), sanitary sewer overflows (SSOs) and stormwater are outlined and a number of myths surrounding their use, dispelled. Reference is made to outputs of peer reviewed comprehensive monitoring, evaluation and demonstration projects on pilot and full-scale installations to demonstrate the efficacy and extensive track record of these systems. Recent developments and innovations in HDVS technologies are discussed, focusing on their combined use as solids liquid separators, contact vessels for wastewater disinfection, the incorporation of self-cleansing screening devices for the control of aesthetic pollutants (e.g. floatables) and the use of computational modelling for optimisation.
Coupling Sensing Hardware with Data Interrogation Software for Structural Health Monitoring
Farrar, Charles R.; Allen, David W.; Park, Gyuhae; ...
2006-01-01
The process of implementing a damage detection strategy for aerospace, civil and mechanical engineering infrastructure is referred to as structural health monitoring (SHM). The authors' approach is to address the SHM problem in the context of a statistical pattern recognition paradigm. In this paradigm, the process can be broken down into four parts: (1) Operational Evaluation, (2) Data Acquisition and Cleansing, (3) Feature Extraction and Data Compression, and (4) Statistical Model Development for Feature Discrimination. These processes must be implemented through hardware or software and, in general, some combination of these two approaches will be used. This paper will discussmore » each portion of the SHM process with particular emphasis on the coupling of a general purpose data interrogation software package for structural health monitoring with a modular wireless sensing and processing platform. More specifically, this paper will address the need to take an integrated hardware/software approach to developing SHM solutions.« less
Final report for demonstration of in situ oxidation of DNAPL using the Geo-Cleanse technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jerome, K.M.; Riha, B.; Looney, B.B.
1997-09-23
At large industrial sites like the A/M Area of the Savannah River Site (SRS), undissolved dense non-aqueous phase liquid (DNAPL) in soil and groundwater is the most significant barrier to successful clean up. DNAPL acts as a reservoir that will continue to generate contaminant levels far above remediation concentration goals well into the future.
USN/USMC Commander’s Quick Reference Handbook for Legal Issues, 2009
2009-01-01
questions. PRIOR QUESTIONING WITHOUT RIGHTS WARNING: Provide " cleansing warning" if someone has previously questioned the member and did not...has expired . GENERAL COURT-MARTIAL (GCM): Article 32 investigation required. Any CA may order an Art 32. Only flag officers (and...GCMCA approves pretrial agreement. GCMCA takes action on findings and sentence after clemency period has expired
Spatial Data from Transportation Studies and Surveys | Transportation
transportation studies and surveys, submit an application for approval to connect to a restricted secure portal environment. For a list of studies and surveys, see cleansed data. Application Process For accessing spatial data, learn about the application and approval process. If you'd like to apply to access the spatial
Srebrenica: The Impossible Choices of a Commander
2008-03-01
ADDRESS(ES) United States Marine Corps, Command and Staff College,Marine Corps University,2076 South Street, Marine Corps Combat Development Command...COMMAND AND STAFF COLLEGE OR ANY OTHER GOVERNMENTAL AGENCY.’ REFERENCES TO THIS STUDY SHOULD INCLUDE THE FOREGOING STATEMENT. QUOTATION FROM...the humanitarian crisis in the former Yugoslavia was strong, especially when the disturbing images ofprison-camps and ethnic cleansing reached the
ERIC Educational Resources Information Center
Klubeck, Martin; Langthorne, Michael; Padgett, Don
2006-01-01
Something new is on the horizon, and depending on one's role on campus, it might be storm clouds or a cleansing shower. Either way, no matter how hard one tries to avoid it, sooner rather than later he/she will have to deal with metrics. Metrics do not have to cause fear and resistance. Metrics can, and should, be a powerful tool for improvement.…
Social Work with Bosnian Muslim Refugee Children and Families: A Review of the Literature
ERIC Educational Resources Information Center
Snyder, Cindy S.; May, J. Dean; Zulcic, Nihada N.; Gabbard, W. Jay
2005-01-01
More than two million Bosnian Muslims were ethnically cleansed in the Balkan region; of these, 200,000 were killed while the others were forced to flee their homes and become refugees. This article focuses on the influence of societal and cultural values coupled with wartime experiences on the transition of Bosnian refugee families to their new…
2011-06-01
World War I, with the memory of a recent defeat to the Japanese still painfully vivid. In 1914, the opportunity of a great social cleansing...the police and reporters, in a recreation of the works of Pushkin and Tolstoy; Chechens have reappeared in Russian cinema . Most of the Russian
Using Mythematics in the Classroom: The Fifth Labor of Hercules
ERIC Educational Resources Information Center
Huber, Michael
2009-01-01
The mythology surrounding Hercules has been a part of human culture for over 2,500 years. In ancient Greek mythology, Eurystheus assigns various labors to Hercules, who has to perform them in order to cleanse his soul. This article treats one of the more famous labors, the fifth labor: The Augean Stables. The labor is provided verbatim from…
Ethnic Cleansing, Yes; Genocide, No: Textbook Coverage of Ethnic Violence in the Former Yugoslavia
ERIC Educational Resources Information Center
Lindquist, David
2012-01-01
The ethnic violence that occurred in the former Yugoslavia during the mid-1990s has become one of the defining events of recent history. As such, today's students should develop an awareness of the history of that situation and its implications for contemporary society. Because textbooks provide the structure of most high school history courses,…
Transplantation of human microbiota into conventional mice durably reshapes the gut microbiota.
Wrzosek, Laura; Ciocan, Dragos; Borentain, Patrick; Spatz, Madeleine; Puchois, Virginie; Hugot, Cindy; Ferrere, Gladys; Mayeur, Camille; Perlemuter, Gabriel; Cassard, Anne-Marie
2018-05-01
Human microbiota-associated (HMA) mice are an important model to study the relationship between liver diseases and intestinal microbiota. We describe a new method to humanize conventional mice based on bowel cleansing with polyethylene glycol followed by fecal microbiota transplantation (FMT) from a human donor. Four successive bowel cleansings were sufficient to empty the intestine and decrease the microbiota by 90%. We then compared four different strategies based on the frequency of FMT over four weeks: (1) twice a week; (2) once a week; (3) two FMTs; (4) one FMT. We were able to transfer human bacteria to mice, irrespective of the strategy used. We detected human bacteria after four weeks, even if only one FMT was performed, but there was a shift of the microbiota over time. FMT twice a week for four weeks was too frequent and perturbed the stability of the newly formed ecosystem. FMT once a week appears to be the best compromise as it allowed engraftment of Faecalibacterium, and a higher diversity of bacteria belonging to the Bacteroidales order. Our easy to establish HMA mouse model could be used as an alternative to classical HMA mice to study the relationship between the liver and the microbiota.
NASA Astrophysics Data System (ADS)
Nuebler-Moritz, Michael; Gutknecht, Norbert; Sailer, Hermann F.; Hering, Peter; Prettl, Wilhelm
1997-05-01
Current endodontic therapy involves debridement and disinfection of the root canal by means of mechanical instrumentation and chemical irrigation. However, several studies have shown that these techniques fail to achieve complete cleansing. Recently, lasers have been suggested for use within root canals. This study was conducted to determine the efficacy of Holmium:YAG laser irradiation in removing intracanal debris and smear layer. Root canal surfaces of freshly-extracted human teeth were exposed to pulsed Ho:YAG laser radiation. Subsequently, laser induced structural changes were investigated using scanning electron microscopy. Temperature measurements during irradiation were performed by means of thermocouples. The result of this survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment modalities. However, limitations exist with regard to circumscribed and well-quantified irradiation of root canal surfaces, due to the lack of perpendicular delivery of the laser beam. Additional studies will be required to develop suitable optical transmission systems, in order to achieve complete cleansing and to avoid damage to the periradicular tissues, respectively.
Foot burns: epidemiology and management.
Hemington-Gorse, S; Pellard, S; Wilson-Jones, N; Potokar, T
2007-12-01
This is a retrospective study of the epidemiology and management of isolated foot burns presenting to the Welsh Centre for Burns from January 1998 to December 2002. A total of 289 were treated of which 233 were included in this study. Approximately 40% were in the paediatric age group and the gender distribution varied dramatically for adults and children. In the adult group the male:female ratio was 3.5:1, however in the paediatric group the male:female ratio was more equal (1.6:1). Scald burns (65%) formed the largest group in children and scald (35%) and chemical burns (32%) in adults. Foot burns have a complication rate of 18% and prolonged hospital stay. Complications include hypertrophic scarring, graft loss/delayed healing and wound infection. Although isolated foot burns represent a small body surface area, over half require treatment as in patients to allow for initial aggressive conservative management of elevation and regular wound cleansing to avoid complications. This study suggests a protocol for the initial acute management of foot burns. This protocol states immediate referral of all foot burns to a burn centre, admission of these burns for 24-48 h for elevation, regular wound cleansing with change of dressings and prophylactic antibiotics.
MR colonography with fecal tagging: do individual patient characteristics influence image quality?
Kinner, Sonja; Kuehle, Christiane A; Langhorst, Jost; Ladd, Susanne C; Nuefer, Michael; Barkhausen, Joerg; Lauenstein, Thomas C
2007-05-01
To evaluate if different patient characteristics influence performance of fecal tagging (a new MR colonography (MRC) technique to label stool to avoid bowel cleansing) and, consecutively, MR image quality. A total of 333 patients (mean age = 61 years) underwent MRC with fecal tagging. Four segments of the large bowel (ascending, transverse, descending, and sigmoid colon) were assessed as for the presence of nontagged stool particles, which can impede an assessment of the colonic wall. Ratings were correlated with patients' characteristics including patient age (<55 vs. > or =55 years), body mass index (BMI) (<25 vs. > or =25), gender, and acceptance levels for fecal tagging. Statistical analysis was performed using a Mann-Whitney U-test. A total of 1332 colonic segments were evaluated. Among them, 327 segments (25%) did not contain any visible stool particles. Considerably reduced image quality was found in 61 segments (5%). Best image quality was found in the sigmoid colon (mean value = 1.9), while image quality of the ascending colon turned out to be worst (mean value = 2.6). Fecal tagging effectiveness showed a reverse correlation with patient age. However, all other characteristics did not have a statistically significant influence on fecal tagging outcome. MRC in conjunction with barium-based fecal tagging led to diagnostic image quality in 95% of all colonic segments. Since tagging results were significantly decreased in patients > or =55 years, tagging protocols should to be modified in this group, i.e., by increasing the time interval of tagging administration. (c) 2007 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Luo, Xiangcheng
Material contacts, including thermal, electrical, seating (fluid sealing and electromagnetic sealing) and mechanical (pressure) contacts, together with their interface materials, were, evaluated, and in some cases, improved beyond the state of the art. The evaluation involved the use of thermal, electrical and mechanical methods. For thermal contacts, this work evaluated and improved the heat transfer efficiency between two contacting components by developing various thermal interface pastes. Sodium silicate based thermal pastes (with boron nitride particles as the thermally conductive filler) as well as polyethylene glycol (PEG) based thermal pastes were developed and evaluated. The optimum volume fractions of BN in sodium silicate based pastes and PEG based pastes were 16% and 18% respectively. The contribution of Li+ ions to the thermal contact conductance in the PEG-based paste was confirmed. For electrical contacts, the relationship between the mechanical reliability and electrical reliability of solder/copper and silver-epoxy/copper joints was addressed. Mechanical pull-out testing was conducted on solder/copper and silver-epoxy/copper joints, while the contact electrical resistivity was measured. Cleansing of the copper surface was more effective for the reliability of silver-epoxy/copper joint than that of solder/copper joint. For sealing contacts, this work evaluated flexible graphite as an electromagnetic shielding gasket material. Flexible graphite was found to be at least comparable to conductive filled silicone (the state of the art) in terms of the shielding effectiveness. The conformability of flexible graphite with its mating metal surface under repeated compression was characterized by monitoring the contact electrical resistance, as the conformability is important to both electromagnetic scaling and fluid waling using flexible graphite. For mechanical contacts, this work focused on the correlation of the interface structure (such as elastic/plastic deformation, oxidation, strain hardening, passive layer damage, fracture, etc.) with the electrical contact resistance, which was measured in real time for contacts under dynamic compression, thus allowing both reversible and irreversible changes to be observed. The materials studied included metals (carbon steel, stainless steel, aluminum and copper), carbon fiber reinforced polymer-matrix composite (nylon-6), ceramic (mortar) and graphite, due to their relevance to fastening, concrete structures, electric brushes and electrical pressure contacts.
DEPRESSED AFFECT AND HISTORICAL LOSS AMONG NORTH AMERICAN INDIGENOUS ADOLESCENTS
Whitbeck, Les B.; Walls, Melissa L.; Johnson, Kurt D.; Morrisseau, Allan D.; McDougall, Cindy M.
2011-01-01
This study reports on the prevalence and correlates of perceived historical loss among 459 North American Indigenous adolescents aged 11–13 years from the northern Midwest of the United States and central Canada. The adolescents reported daily or more thoughts of historical loss at rates similar to their female caretakers. Confirmatory factor analysis indicated that our measure of perceived historical loss and the Center for Epidemiologic Studies Depression scale were separate but related constructs. Regression analysis indicated that, even when controlling for family factors, perceived discrimination, and proximal negative life events, perceived historical loss had independent effects on adolescent’s depressive symptoms. The construct of historical loss is discussed in terms of Indigenous ethnic cleansing and life course theory. PMID:20052631
Depressed affect and historical loss among North American Indigenous adolescents.
Whitbeck, Les B; Walls, Melissa L; Johnson, Kurt D; Morrisseau, Allan D; McDougall, Cindy M
2009-01-01
This study reports on the prevalence and correlates of perceived historical loss among 459 North American Indigenous adolescents aged 11-13 years from the northern Midwest of the United States and central Canada. The adolescents reported daily or more thoughts of historical loss at rates similar to their female caretakers. Confirmatory factor analysis indicated that our measure of perceived historical loss and the Center for Epidemiologic Studies Depression scale were separate but related constructs. Regression analysis indicated that, even when controlling for family factors, perceived discrimination, and proximal negative life events, perceived historical loss had independent effects on adolescents' depressive symptoms. The construct of historical loss is discussed in terms of Indigenous ethnic cleansing and life course theory.
Cormier, Ethel M; Sarlo, Katherine; Scott, Laurie A; MacKenzie, David P; Payne, Nicholas S; Carr, Gregory J; Smith, Laurence A; Cua-Lim, Felicidad; Bunag, Filipino C; Vasunia, Kersi
2004-05-01
Enzymes have been safely used in laundry products for many years. The risk of developing adverse responses to enzymes in laundry detergents among consumers in countries where hand laundry predominates is expected to be low. To understand how consumers in hand laundry markets used detergent products; to show that use of enzyme-containing detergents did not lead to sensitization in an atopic population with compromised skin; and to show that enzyme detergents did not have an adverse effect on skin condition. Women in the rural Philippines were chosen since they do hand laundry for several hours a day, every day. The skin prick test (SPT) tested for the presence of IgE antibody to common aeroallergens and to enzymes in detergent product. Atopic women used enzyme-containing laundry bars for hand laundry and personal cleansing. They also used enzyme-containing laundry granules for hand laundry. All subjects were evaluated by SPT with enzymes over 2 years. Hand and body skin conditions were also evaluated. None of the 1,980 subjects screened for eligibility into the 2-year study were SPT positive to enzymes, including 655 women who used enzyme-containing detergent for up to 1 year. None of the subjects in the study developed IgE to the enzymes. Enzymes had no adverse effect on skin condition or on the development of erosions on the hands. The 2-year study confirms that enzymes are safe for use in laundry products at or below levels tested in the study even when used by atopic consumers under extremely harsh conditions.
Disinfection capacity of PuriLens contact lens cleaning unit against Acanthamoeba.
Hwang, Thomas S; Hyon, Joon Young; Song, Jae Kyung; Reviglio, Victor E; Spahr, Harry T; O'Brien, Terrence P
2004-01-01
The PuriLens contact lens system is indicated for cleaning and disinfection of soft (hydrophilic) contact lenses by means of subsonic agitation to remove lens deposits and microorganisms, and ultraviolet irradiation of the storage solution for disinfection. The capacity of the PuriLens system to disinfect storage solutions contaminated with known concentrations of Staphylococcus aureus, Pseudomonas aeruginosa, and Acanthamoeba species was evaluated. An in vitro assessment of the antibacterial and antiparasitic efficacy of the PuriLens system was performed. Separated batches of the storage solution for the cleansing system were contaminated with stock strains of S. aureus and P. aeruginosa. A comparison of the microbiologic content was made between the solution before and after the cycle. The PuriLens system effectively eradicated S. aureus and P. aeruginosa organisms after a 15-minute cycle. However, viable cysts of acanthamoeba were recovered in the solution after the 15-minute cycle. The PuriLens system is highly efficient in protecting against contamination with common bacterial ocular pathogens. Acanthamoeba cysts, however, can survive in the solution or contact lens bath undergoing integrated subsonic debridement and indirect ultraviolet light disinfection. Use of chemical disinfecting solutions that contain agents such as chlorhexidine or other cationic antiseptics may be advisable in conjunction with use of the PuriLens device, especially in high-risk settings.
[Current status of disinfection and sterilization for dental handpieces in the hospitals].
Deng, Xiao-hong; Sun, Zheng; Su, Jing
2004-11-01
To understand current status of the uses of dental handpieces, methods of disinfection and sterilization and their effectiveness in dental-care hospitals and out-patient departments of stomatology in general hospitals. Ten dental-care hospitals and departments of stomatology in general hospitals at varied levels were randomly sampled during 2000 to 2001 to investigate the uses of dental handpieces and means of their disinfection and sterilization. One used dental handpiece from each hospital or department of stomatology in general hospital selected was detected for possible contamination of bacteria by aerobic bacterial count and Coliform bacterial examinations and hepatitis B surface antigen (HBsAg) on it, based on "The Technical Standards for Disinfection" set by the Ministry of Health of China, and the effectiveness of its disinfection and sterilization was evaluated as well. Anti-suction handpieces were used only in 5.9% of the hospitals or departments, 94.1% of them without anti-suction devices. Cleansing disinfection was applied for used dental handpieces in 62.9% of the dental-care hospitals and the departments of stomatology, with an effective rate of 26.17%, immersing disinfection in 10.0%, with an effective rate of 55.88%, and autoclave in 27.1%, with an effective rate of 80.43%. Used dental handpieces in the hospitals and departments of stomatology in general hospitals were all contaminated by bacteria and HBsAg could be detected in 1.67% of them. Dental handpieces without anti-suction should be replaced soon by those with it or comprehensive dental unit with anti-suction device should be used. Used dental handpieces must be sterilized effectively before next use. Awareness on prevention from cross-infection should be improved for dental-care professional staff and operation of sterilization should be standardized.
Extremity gunshot wound and gunshot fracture in civilian practice.
Hennessy, M J; Banks, H H; Leach, R B; Quigley, T B
1976-01-01
The civilian gunshot wound is a low velocity injury. Temporary cavitation does not occur in the low velocity wound and damage is confined to the projectile pathway. Extensive debridement is not indicated for this injury. Surgical cleansing is used to convert the open, contaminated wound to a clean, closed wound. Reparative and definitive reconstruction then follow to restore form and function with minimized patient hazard.
21 CFR 349.78 - Labeling of eyewash drug products.
Code of Federal Regulations, 2011 CFR
2011-04-01
... product with one or more of the following terms: “eyewash,” “eye irrigation,” or “eye irrigating solution...,” or “bathing”) “the eye to remove” (select one or more of the following: “loose foreign material...: “flushing,” “irrigating,” “cleansing,” “washing,” or “bathing”) “the eye to help relieve” (select one or...
21 CFR 349.78 - Labeling of eyewash drug products.
Code of Federal Regulations, 2010 CFR
2010-04-01
... product with one or more of the following terms: “eyewash,” “eye irrigation,” or “eye irrigating solution...,” or “bathing”) “the eye to remove” (select one or more of the following: “loose foreign material...: “flushing,” “irrigating,” “cleansing,” “washing,” or “bathing”) “the eye to help relieve” (select one or...
Airpower in Mass Atrocity Response Operations (MARO)
2012-06-01
status quo rather than initiating wars themselves as an instrument of policy.6 French strategist, Army Brigadier-General Loup Francart, described...Robert Rotberg (Washington: World Peace Foundation, 2010), 159-174. 25 and therefore, many of the basic ingredients for a Mass Atrocity...of life was the result of either purposeful violence or the willful neglect of basic needs. Often the aim of an atrocity is “ethnic cleansing
Abnormal /sup 67/Ga-citrate scan of the abdomen in tuberculous peritonitis: case report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinbach, J.J.
1976-04-01
Tuberculous peritonitis in a 34-year-old alcoholic man was associated with an abnormal /sup 67/Ga-citrate scan of the abdomen. Repeated studies after thorough bowel cleansing revealed no change in the site and shape of the abnormality for 2 to 5 days after injection of the tracer. The inflammatory process may have been responsible for the abnormal scan. (auth)
ERIC Educational Resources Information Center
Priem, Karin
2016-01-01
This article focuses on senses, emotions and cultural practices such as writing, reading and speaking in West Germany after 1945. The period immediately following the end of the Second World War--the so-called "Stunde Null", or "zero hour"--has generally been seen as a time of new beginnings, also with regard to cleansing the…
Quantifying urban forest structure, function, and value: the Chicago Urban Forest Climate Project
E. Gregory McPherson; David Nowak; Gordon Heisler; Sue Grimmond; Catherine Souch; Rich Grant; Rowan Rowntree
1997-01-01
This paper is a review of research in Chicago that linked analyses of vegetation structure with forest functions and values. During 1991, the region's trees removed an estimated 5575 metric tons of air pollutants, providing air cleansing worth $9.2 million. Each year they sequester an estimated 315 800 metric tons of carbon. Increasing tree cover 10% or planting...
NASA Technical Reports Server (NTRS)
Finogenov, A. M.; Azhayev, A. N.; Kaliberdin, G. V.
1975-01-01
The biomedical maintenance of astronauts is discussed in terms of personal hygiene. Principal characteristics and general requirements are described which must be followed in perfecting a system of hygienic practices and in devising means to maintain personal hygiene, flight clothing, underwear, bedding, and medical-domestic equipment for manned space flights of varying durations. Factors discussed include: disposable clothing, thermal protection, oral hygiene, cleansing of the skin, and grooming of the hair.
Mullany, Luke C; Darmstadt, Gary L; Khatry, Subarna K; Katz, Joanne; LeClerq, Steven C; Shrestha, Shardaram; Adhikari, Ramesh; Tielsch, James M
2008-01-01
Summary Background Omphalitis contributes to neonatal morbidity and mortality in developing countries. Umbilical cord cleansing with antiseptics might reduce infection and mortality risk, but has not been rigorously investigated. Methods In our community-based, cluster-randomised trial, 413 communities in Sarlahi, Nepal, were randomly assigned to one of three cord-care regimens. 4934 infants were assigned to 4·0% chlorhexidine, 5107 to cleansing with soap and water, and 5082 to dry cord care. In intervention clusters, the newborn cord was cleansed in the home on days 1−4, 6, 8, and 10. In all clusters, the cord was examined for signs of infection (pus, redness, or swelling) on these visits and in follow-up visits on days 12, 14, 21, and 28. Incidence of omphalitis was defined under three sign-based algorithms, with increasing severity. Infant vital status was recorded for 28 completed days. The primary outcomes were incidence of neonatal omphalitis and neonatal mortality. Analysis was by intention-to-treat. This trial is registered with Clinicaltrials.gov, number NCT00109616. Findings Frequency of omphalitis by all three definitions was reduced significantly in the chlorhexidine group. Severe omphalitis in chlorhexidine clusters was reduced by 75% (incidence rate ratio 0·25, 95% CI 0·12−0·53; 13 infections/4839 neonatal periods) compared with dry cord-care clusters (52/4930). Neonatal mortality was 24% lower in the chlorhexidine group (relative risk 0·76 [95% CI 0·55−1·04]) than in the dry cord care group. In infants enrolled within the first 24 h, mortality was significantly reduced by 34% in the chlorhexidine group (0·66 [0·46−0·95]). Soap and water did not reduce infection or mortality risk. Interpretation Recommendations for dry cord care should be reconsidered on the basis of these findings that early antisepsis with chlorhexidine of the umbilical cord reduces local cord infections and overall neonatal mortality. PMID:16546539
Ursin, F; Steger, F; Borelli, C
2018-04-28
Recipes for peelings date back to medical texts of old Egypt. The oldest medical papyri contain recipes for "improving beauty of the skin" and "removing wrinkles" by use of agents like salt and soda. The Egyptian Queen Cleopatra (69-30 BC) is said to have taken bathes in donkey's milk in order to improve the beauty of her skin. However, little is known about other agents and peeling applications in later Greek medical textbooks. We will discover new agents and describe ancient peeling applications. First, we will have to identify ancient Greek medical terms for the modern terms "peeling" and "chemical peeling". Second, based on the identified terms we will perform a systematic fulltext search for agents in original sources. Third, we will categorize the results into three peeling applications: (1) cleansing, (2) aesthetical improvement of the skin, and (3) therapy of dermatological diseases. We performed a full systematic keyword search with the identified Greek terms in databases of ancient Greek texts. Our keywords for peeling and chemical peeling are "smēxis" and "trīpsis". Our keywords for agents of peeling and chemical peeling are "smégmata", "rhýmmata", "kathartiká", and "trímmata". Diocles (4 th century BC) was the first one who mentioned "smēxis" and "trīpsis" as parts of daily cleansing routine. Criton (2 nd century AD) wrote about peeling applications, but any reference to the agents is lost. Antyllos (2 nd century AD) composed three lists of peeling applications including agents. Greek medical textbooks of Graeco-Roman antiquity report several peeling applications like cleansing, brightening, darkening, softening, and aesthetical improvement of the skin by use of peeling and chemical peeling, as well as therapy of dermatological diseases. There are 27 ancient agents for what is contemporarily called peeling and chemical peeling. We discovered more specific agents than hitherto known to research. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Dental health professional recommendation and consumer habits in denture cleansing.
Axe, Alyson S; Varghese, Roshan; Bosma, MaryLynn; Kitson, Nicola; Bradshaw, David J
2016-02-01
Regular cleaning of dentures is essential to the oral and general health of denture wearers. Only limited systematic data are available on the recommendations that dental health care professionals (DHCPs) make to patients for denture cleaning. Data on denture wearers' cleaning regimens are also lacking. The purpose of this study was to provide data on recommendations that DHCPs make to patients for denture cleaning and on the cleaning regimens of denture wearers. DHCPs (n=613), including dentists and hygienists, were surveyed in developed (Japan, USA, Italy) and developing (Brazil, India) countries. A questionnaire assessing a range of denture cleaning recommendations was used. The questions addressed products, frequency, how to use remedies, the suggested dilution and duration of cleansing treatment, the location of dentures while cleaning, and the reasoning behind the recommendation of particular products or modes of treatment. Denture cleansing methods and the routine of denture wearers in developed and developing countries were also surveyed with a questionnaire (n=2862) and a 1-week diary (n=1462). An average of more than 2 treatments was recommended by DHCPs. Specialist denture cleanser tablets, "regular" toothpaste, mouthwash, soap and water, denture paste, foam or liquid denture cleanser, and dishwashing detergents were most commonly recommended; other product recommendations included baking soda, vinegar, salt water, and bleach. More than 10% of DHCPs made no primary recommendation on cleaning. Denture tablets were more commonly recommended in developed countries, whereas toothpaste was the most common recommendation in developing countries. Denture wearers used products and methods similar to those recommended by DHCPs. Toothpaste, water, and mouthwash were used more frequently than denture tablets. More than 75% of denture wearers reported using denture cleanser tablets for more than 5 minutes, whereas soap and toothpaste were typically used for less than 2 minutes. DHCP recommendations and denture wearer habits are diverse, with no consensus on the most appropriate denture cleaning methods. This reflects a lack of clear, systematic evidence upon which to base recommendations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Lubiprostone: clinical applications beyond constipation.
Kapoor, Shailendra
2009-03-07
In comparison to polyethylene glycol, lubiprostone offers other advantages and is increasingly being used as an adjunctive agent in diagnostic as well as management strategies not only in gastroenterology, but in other fields. For instance, lubiprostone exerts beneficial effects in cystic fibrosis tissues. It augments the chloride secretion in these cells by activating non-cystic fibrosis transmembrane regulator (CFTR) secretion of chloride by afflicted respiratory epithelia. Lubiprostone also seems to improve visualization of the gastrointestinal tract during procedures such as colonoscopy. This is especially true if the lubiprostone is administered prior to bowel cleansing with agents such as polyethylene glycol electrolyte (PEG-E). Lubiprostone also enhances and stimulates contraction in colonic as well as gastric muscles and may thus further contribute as a prokinetic agent. Besides these effects, lubiprostone also causes hyperpolarization in other tissues such as uterine muscle cells. This may prove to be of significant clinical benefit in the management of uterine pathologies in the near future.
Lubiprostone: Clinical applications beyond constipation
Kapoor, Shailendra
2009-01-01
In comparison to polyethylene glycol, lubiprostone offers other advantages and is increasingly being used as an adjunctive agent in diagnostic as well as management strategies not only in gastroenterology, but in other fields. For instance, lubiprostone exerts beneficial effects in cystic fibrosis tissues. It augmernts the chloride secretion in these cells by activating non-cystic fibrosis transmembrane regulator (CFTR) secretion of chloride by afflicted respiratory epithelia. Lubiprostone also seems to improve visualization of the gastrointestinal tract during procedures such as colonoscopy. This is especially true if the lubiprostone is administered prior to bowel cleansing with agents such as polyethylene glycol electrolyte (PEG-E). Lubiprostone also enhances and stimulates contraction in colonic as well as gastric muscles and may thus further contribute as a prokinetic agent. Besides these effects, lubiprostone also causes hyperpolarization in other tissues such as uterine muscle cells. This may prove to be of significant clinical benefit in the management of uterine pathologies in the near future. PMID:19266613
A review of shampoo surfactant technology: consumer benefits, raw materials and recent developments.
Cornwell, P A
2018-02-01
Surfactants form the core of all shampoo formulations, and contribute to a wide range of different benefits, including cleansing, foaming, rheology control, skin mildness and the deposition of benefit agents to the hair and scalp. The purpose of this review was to assist the design of effective, modern, shampoo surfactant technologies. The mechanisms through which surfactants help deliver their effects are presented, along with the appraisal techniques through which surfactant options can be tested and screened for product development. The steps that should be taken to select the most appropriate blend of surfactants are described, and useful information on the most widely used surfactants is provided. The review concludes with an examination of recent developments in 'greener' surfactants, 'sulphate-free' technologies and structured liquid phases for novel sensory properties and for suspending benefit agents. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Wound bed preparation: A novel approach using HydroTherapy.
Atkin, Leanne; Ousey, Karen
2016-12-01
Wounds that fail to heal quickly are often encountered by community nursing staff. An important step in assisting these chronic or stalled wounds progress through healing is debridement to remove devitalised tissue, including slough and eschar, that can prevent the wound from healing. A unique wound treatment called HydroTherapy aims to provide an optimal healing environment. The first step of HydroTherapy involves HydroClean plus™, this dressing enables removal of devitalised tissue through autolytic debridement and absorption of wound fluid. Irrigation and cleansing provided by Ringer's solution from the dressing further removes any necrotic tissue or eschar. Once effective wound bed preparation has been achieved a second dressing, HydroTac™, provides an ongoing hydrated wound environment that enables re-epithelialisation to occur in an unrestricted fashion. This paper presents 3 case studies of slow healing wounds treated with HydroClean plus™ which demonstrates effective wound debridement.
Treatment-induced mucositis: an old problem with new remedies.
Symonds, R P
1998-05-01
Mucositis may be a painful, debilitating, dose-limiting side-effect of both chemotherapy and radiotherapy for which there is no widely accepted prophylaxis or effective treatment. The basis of management is pain relief, prevention of dehydration and adequate nutrition. When tested vigorously, most antiseptic mouthwashes and anti-ulcer agents are ineffective. Simple mechanical cleansing by saline is the most effective traditional measure. A variety of new agents are effective. Granulocyte macrophage colony-stimulating factor (GM-CSF) and granulocyte colony-stimulating factor (G-CSF) act outwith the haemopoeitic system and can reduce mucositis, but the best schedule, dosage and method of administration is not known or which is the best growth factor to prevent this side-effect. A placebo-controlled randomized trial of antibiotic pastilles has shown a significant reduction in mucositis and weight loss during radiotherapy for head and neck cancer. Another method to reduce radiation effects in normal tissue is to stimulate cells to divide before radiotherapy by silver nitrate or interleukin 1. These methods may be particularly effective when given along with hyperfractionated radiation treatment such as CHART.
Topical effectiveness of a cosmetic skincare treatment for acne-prone skin: a clinical study.
Bartenjev, Igor; Oremović, Lenka; Rogl Butina, Mirjam; Sjerobabski Masnec, Ines; Bouloc, Anne; Voda, Karmen; Šitum, Mirna
2011-06-01
Physiological acne is a milder form of clinical acne and is very frequent in adult women (18 years of age and older). Acne therapy is usually unnecessary in such cases, and so appropriate cosmetic treatments are sought. To determine the effectiveness of a topical cosmetic hydrating skincare treatment for adult acne-prone skin (Normaderm, Vichy, France) against the clinical signs of physiological acne: few inflammatory and retentional lesions, uneven (grainy) skin relief, dilated pores, and occasional and/or local hyperseborrhea. Within the study, the tested product's keratolytic, antimicrobial, and antiseborrheic properties, and its overall ability to improve the clinical signs of physiological acne present in adult subjects were evaluated through objective and clinical evaluation methods by the investigators and through self-evaluation questionnaires by the subjects themselves. The study group was composed of 50 adult women between 18 and 35 years of age with combination or oily acne-prone skin, who were chosen according to previously defined inclusion criteria. They applied the product tested twice daily on thoroughly cleansed skin for a period of 2 months. The results were evaluated after 30 (±2) and 60 (±2) days. The number of inflammatory and retentional lesions on the forehead, cheeks, and chin decreased after 60 days of use (an average of 30.7% and 70.7%, respectively). The level of sebum secretion on the forehead decreased by 33.4% and the level of skin scaling decreased by 38.5% after 60 days of use. The moisture content in the horny layer on the forehead, cheeks, and chin increased by an average 39.7%. The decrease in pore size and content after 60 days of use was very noticeable. The subjects evaluated all the studied characteristics of the product tested very positively, with results already showing after 30 days of use. The results of the study confirm that the product tested is suitable for the cosmetic care of adult acne-prone skin, either as an independent cosmetic hydrating skincare treatment, as a complementary cosmetic part of acne therapy, or as a subsequent cosmetic regimen to sustain the results of the acne therapy for a longer period of time.
Corneal Injury from Presurgical Chlorhexidine Skin Preparation.
Bever, Gregory J; Brodie, Frank L; Hwang, David G
2016-12-01
Chlorhexidine skin preparation has been shown to provide highly effective antimicrobial presurgical skin cleansing. However, there is a significant risk of ocular toxicity when it is used in periocular areas. We describe 2 cases of significant corneal damage resulting from 4% chlorhexidine gluconate preoperative skin cleanser, despite the use of protective occlusive dressing over the eyes. Because of the potential for severe corneal toxicity resulting from use of chlorhexidine, alternative agents such as 10% povidone-iodine should be considered for skin preparation near periocular areas whenever possible. If chlorhexidine gluconate must be employed near periocular areas, great care must be exercised to avoid contact with the eyes, and additional protective measures (e.g., absorbent eye pads along with tightly occlusive dressings) must be used whenever possible. Copyright © 2016 Elsevier Inc. All rights reserved.
Skin-to-skin contact and/or oral 25% dextrose for procedural pain relief for term newborn infants.
Chermont, Aurimery Gomes; Falcão, Luis Fábio Magno; de Souza Silva, Eduardo Henrique Laurindo; de Cássia Xavier Balda, Rita; Guinsburg, Ruth
2009-12-01
The goal was to compare the efficacy of oral 25% dextrose treatment and/or skin-to-skin contact for analgesia in term newborns during intramuscular injection of a hepatitis B vaccine. A prospective, randomized, partially blinded, clinical trial was performed with 640 healthy term newborns. Infants at 12 to 72 hours of life were assigned randomly to receive an intramuscular injection of hepatitis B vaccine in the right thigh according to 4 analgesia groups, that is, no analgesia (routine); oral 25% dextrose treatment, given 2 minutes before the injection; skin-to-skin contact, initiated 2 minutes before the injection and persisting throughout the procedure; and a combination of the oral dextrose treatment and skin-to-skin contact strategies. For all groups, Neonatal Facial Coding System and Neonatal Infant Pain Scale scores were evaluated before the procedure, during thigh cleansing, during the injection, and 2 minutes after the injection. Premature Infant Pain Profile scores also were assessed for all infants. Pain scores were compared among the 4 groups. The use of oral 25% dextrose treatment reduced the duration of procedural pain in the studied population. Skin-to-skin contact decreased injection pain and duration. The combination of the 2 analgesic measures was more effective than either measure separately for term newborns. Nonpharmacologic analgesic measures were effective for the treatment of procedural pain in term infants. The combination of oral 25% dextrose treatment and skin-to-skin contact acted synergistically to decrease acute pain in healthy neonates.
Decontamination of Combat Wounds in the Injured Soldier
1980-08-01
to the civilian population. In this category were studies on skin grafting , amputations, cellulitis and gangrene, and burns ""cMiTV CLASSIPICATION OP...Cleansing 4. High Pressure irrigation 5. Proteolytic Enzymes 6. Antiseptic Agents 7. Gram Stain C. Adjunctive Studies 1. Skin Grafts 2. Fingertip...studies which explored problems that were also of benefit to the civilian population. In this category were studies on skin grafting , amputations
2011-09-01
low‐cost, lightweight, single‐use individual product for field self ‐decontamination. Surface (skin) decontamination of Bacillus subtilis spores has...field spray decontamination unit was previously demonstrated in 2003 at Guantanamo Bay, Cuba (Dankert, 2003), and for wound healing with repeated...Technology on plastics, rubber and plastic tubing, and clothing. Demonstrate ability of CleanseFx to function as skin cleanser in military setting
Report to the Congress on the Strategic Defense Initiative, 1989
1989-03-13
veterinarians for its ability to cleanse harmful viruses from bovine semen so it can be used for artificial insemination . This process is also being...pointing out major advances in small, lightweight and affordable components for defensive interceptors; sensor developments for satellites and ground- based...test satellites . The United States view is that the number of designated ABM test satellites in orbit simultaneously shall not exceed a number well
Langley Air Force Base Marina Repair Environmental Assessment
2004-08-16
of human perception for extended periods of time; cosmetic or structural damage could occur to buildings. Table 3-8 presents the minimum distance at...Hazardous Waste Storage Areas (HWSA) where they are stored until disposal is economically practicable or before 90 days has expired , whichever comes...Shop, where paintss paint thinners, ·paint mixing, and cleansing of paint equipment took place between 1950 md 1991. The other is the gasoline storage
China Report, Economic Affairs.
1985-01-16
indirect benefits ( ecological benefits). For example, they regulate the climate, conserve water and soil, beautify the environment, and cleanse the...mankind’s need for wood and wooden articles will not only not decline, but will rapidly grow. Therefore, the possibility of using forests as a source...lack firewood for 90 to 150 days dur- ing the year. In areas with serious shortage, they are actually without fire- wood half the time every year
Chicago's urban forest ecosystem: results of the Chicago Urban Forest Climate Project
Gregory E. McPherson; David J. Nowak; Rowan A. Rowntree
1994-01-01
Results of the 3-year Chicago Urban Forest Climate Project indicate that there are an estimated 50.8 million trees in the Chicago area of Cook and DuPage Counties; 66 percent of these trees rated in good or excellent condition. During 1991, trees in the Chicago area removed an estimated 6,145 tons of air pollutants, providing air cleansing valued at $9.2 million...
The Promise and the Peril of the Responsibility to Protect
2012-02-21
ORGANIZATION NAME(S) AND ADDRESS(ES) AND ADDRESS(ES) 8 . PERFORMING ORGANIZATION REPORT NUMBER Colonel (Retired) Allen D. Raymond U.S. Army...protect populations from genocide , war crimes, ethnic cleansing and crimes against humanity. Serious differences in how sovereign governments and...rebellion as a case study of the use of force under the auspices of The Responsibility to Protect. 15. SUBJECT TERMS Genocide , War Crimes, Ethnic
[Treatment of pubic osteomyelitis secondary to pressure sores].
Brunel, Anne-Sophie; Téot, Luc; Lamy, Brigitte; Masson, Raphaël; Morquin, David; Reynes, Jacques; Le Moing, Vincent
2014-01-01
There is no consensus regarding the diagnostic and therapeutic strategy for pubic osteomyelitis secondary to pelvic pressure sores. Diagnosis is often difficult and bone biopsies with microbiological and anatomical-pathological examination remain the gold standard. The rate of cicatrisation of pressure sores is low. Cleansing and negative pressure treatment are key elements of the treatment. Optimising the care management with medical-surgical collaboration is being studied in the Ostear protocol.
Mass Storage Performance Information System
NASA Technical Reports Server (NTRS)
Scheuermann, Peter
2000-01-01
The purpose of this task is to develop a data warehouse to enable system administrators and their managers to gather information by querying the data logs of the MDSDS. Currently detailed logs capture the activity of the MDSDS internal to the different systems. The elements to be included in the data warehouse are requirements analysis, data cleansing, database design, database population, hardware/software acquisition, data transformation, query and report generation, and data mining.
Chua, Evan M; Shimeta, Jeff; Nugegoda, Dayanthi; Morrison, Paul D; Clarke, Bradley O
2014-07-15
Microplastic particles (MPPs; <5 mm) are found in skin cleansing soaps and are released into the environment via the sewage system. MPPs in the environment can sorb persistent organic pollutants (POPs) that can potentially be assimilated by organisms mistaking MPPs for food. Amphipods (Allorchestes compressa) exposed to MPPs isolated from a commercial facial cleansing soap ingested ≤45 particles per animal and evacuated them within 36 h. Amphipods were exposed to polybrominated diphenyl ether (PBDEs) congeners (BDE-28, -47, -99, -100, -153, -154, and -183) in the presence or absence of MPPs. This study has demonstrated that PBDEs derived from MPPs can be assimilated into the tissue of a marine amphipod. MPPs reduced PBDE uptake compared to controls, but they caused greater proportional uptake of higher-brominated congeners such as BDE-154 and -153 compared to BDE-28 and -47. While MPPs in the environment may lower PBDE uptake compared to unabsorbed free chemicals, our study has demonstrated they can transfer PBDEs into a marine organism. Therefore, MPPs pose a risk of contaminating aquatic food chains with the potential for increasing public exposure through dietary sources. This study has demonstrated that MPPs can act as a vector for the assimilation of POPs into marine organisms.
A new fractional order derivative based active contour model for colon wall segmentation
NASA Astrophysics Data System (ADS)
Chen, Bo; Li, Lihong C.; Wang, Huafeng; Wei, Xinzhou; Huang, Shan; Chen, Wensheng; Liang, Zhengrong
2018-02-01
Segmentation of colon wall plays an important role in advancing computed tomographic colonography (CTC) toward a screening modality. Due to the low contrast of CT attenuation around colon wall, accurate segmentation of the boundary of both inner and outer wall is very challenging. In this paper, based on the geodesic active contour model, we develop a new model for colon wall segmentation. First, tagged materials in CTC images were automatically removed via a partial volume (PV) based electronic colon cleansing (ECC) strategy. We then present a new fractional order derivative based active contour model to segment the volumetric colon wall from the cleansed CTC images. In this model, the regionbased Chan-Vese model is incorporated as an energy term to the whole model so that not only edge/gradient information but also region/volume information is taken into account in the segmentation process. Furthermore, a fractional order differentiation derivative energy term is also developed in the new model to preserve the low frequency information and improve the noise immunity of the new segmentation model. The proposed colon wall segmentation approach was validated on 16 patient CTC scans. Experimental results indicate that the present scheme is very promising towards automatically segmenting colon wall, thus facilitating computer aided detection of initial colonic polyp candidates via CTC.
Urinary excretion of polyethylene glycol 3350 during colonoscopy preparation.
Rothfuss, K S; Bode, J C; Stange, E F; Parlesak, A
2006-02-01
Whole gut lavage with a polyethylene glycol electrolyte solution (PEG) is a common bowel cleansing method for diagnostic and therapeutic colon interventions. Absorption of orally administered PEG from the gastrointestinal tract in healthy human beings is generally considered to be poor. In patients with inflammatory bowel disease (IBD), intestinal permeability and PEG absorption were previously reported to be higher than in normal subjects. In the current study, we investigated the absorption of PEG 3350 in patients undergoing routine gut lavage. Urine specimens were collected for 8 hours in 24 patients undergoing bowel cleansing with PEG 3350 for colonoscopy. The urinary excretion of PEG 3350, measured by size exclusion chromatography, ranged between 0.01 and 0.51 % of the ingested amount, corresponding to 5.8 and 896 mg in absolute amounts, respectively. Mean PEG excretion in patients with impaired mucosa such as inflammation or ulceration of the intestine (0.24 % +/- 0.19, n = 11) was not significantly higher (p = 0.173) compared to that in subjects with macroscopically normal intestinal mucosa (0.13 % +/- 0.13, n = 13). The results indicate that intestinal absorption of PEG 3350 is higher than previously assumed and underlies a strong inter-individual variation. Inflammatory changes of the intestine do not necessarily lead to a significantly higher permeability of PEG.
Non-fragrance allergens in specific cosmetic products.
Travassos, Ana Rita; Claes, Lieve; Boey, Lies; Drieghe, Jacques; Goossens, An
2011-11-01
Reports about the nature of the ingredients responsible for allergic contact dermatitis caused by specific cosmetic products are scarce. Between January 2000 and December 2010, the specific cosmetic products having caused allergic contact dermatitis, as well as the individual allergenic cosmetic ingredients present in them, were recorded by use of a standardized form. Among 11 different categories of cosmetic product, skin care products, followed by hair care and body-cleansing products, were most often involved. The presence of the allergenic ingredient(s) in a specific cosmetic product was confirmed according to the ingredient label in 959 of 1448 records. Six hundred and twenty-one of 959 concerned non-fragrance components, preservatives being responsible for 58% of them. Reactions to formaldehyde and formaldehyde-releasers were most often correlated with body-cleansing products, particularly 2-bromo-2-nitropropane-1,3-diol and skin care products. They were followed by the methylchloroisothiazolinone/methylisothiazolinone mixture, most frequently found as allergens in hair care and intimate hygiene products, and facial cleansers (in the last category together with diazolidinyl urea). Octocrylene was by far the most frequent (photo)allergen in sun care products. This study provides information on the presence and frequency of allergens in specific causal cosmetic products. © 2011 John Wiley & Sons A/S.
Variation in feminine hygiene practices as a function of age.
Czerwinski, B S
2000-01-01
To examine variation in feminine hygiene practices as a function of increasing age. A nonexperimental, descriptive research design with study sample stratified by age. Women over 18 years of age. Of 713 women who completed and returned the feminine hygiene practices questionnaire, 180 were younger than 41 years, 171 were 41-48 years, 184 were 49-57 years, and 178 were 58 years or older. All participants were members of a California professional home economics organization. A 40-item feminine hygiene practices questionnaire dealing with body cleansing practices, feminine products usage, and both general and specific menses collection and protection practices. Significant age-related differences were found in several areas of body cleansing and feminine products usage, including sponge bathing and use of feminine and deodorant spray, wet wipes, and panty liners. In all age groups, 20-30% of women reported douching, even in the face of continued reports of the dangers in this practice. In addition, reduced numbers of women (n = 245) in all age groups reported washing hands before using tampons or pads, although more (n = 314) reported washing their hands afterward. Continuing education about proper feminine hygiene practices, especially regarding douching and handwashing before and after genitourinary contact, will be important across all age groups.
Cho, JeongHyeon; Lee, SeungHee; Shin, Jung A; Kim, Jeong Ho; Lee, Hong Sub
2017-09-01
Few studies have evaluated the use of a smartphone application (app) for educating people undergoing colonoscopy and optimizing bowel preparation. Therefore, this study was designed to develop a smartphone app for people to use as a preparation guide and to evaluate the efficacy of this app when used prior to colonoscopy. In total, 142 patients (male:female=84:58, mean age=43.5±9.3 years), who were scheduled to undergo a colonoscopy at Myongji Hospital, were enrolled in this study. Seventy-one patients were asked to use a smartphone app that we had recently developed to prepare for the colonoscopy, while the 71 patients of the sex and age-matched control group were educated via written and verbal instructions. The quality of bowel cleansing, evaluated using the Boston Bowel Preparation Scale, was significantly higher in the smartphone app group than in the control group (7.70±1.1 vs. 7.24±0.8, respectively, p =0.007 by t -test). No significant differences were found between the two groups regarding work-up time and the number of patients with polyps. In this study, targeting young adults (≤50 years), the bowel preparation achieved by patients using the smartphone app showed significantly better quality than that of the control group.
Tejwani, Samir G; Chen, Jason; Funahashi, Tadashi T; Love, Rebecca; Maletis, Gregory B
2015-11-01
Allograft tissue is a common graft choice for anterior cruciate ligament reconstruction (ACLR). Allograft sterilization methods vary widely across numerous commercial tissue vendors. Multiple studies, despite being limited in sample size, have suggested a higher rate of clinical failure associated with the use of allograft tissue in ACLR when compared with autograft. To examine the association of graft processing techniques, patient characteristics, and graft type with risk of revision surgery after allograft ACLR. Cohort study; Level of evidence, 3. A retrospective cohort study was conducted that used an integrated United States health care system's ACLR registry to identify primary unilateral cases in which allografts were used. Aseptic revision was the endpoint of the study. Allograft type, processing methods (irradiation dose, AlloWash, AlloTrue, BioCleanse), and graft donor age were assessed as potential risk factors for revision, with adjustment for patient age, sex, and body mass index (BMI) by use of survival analysis. Hazard ratios (HR) and 95% confidence intervals (CIs) were calculated. A total of 5968 primary ACLR cases with allograft were included in the study, of which 3688 (61.8%) were male patients. The median age of the cohort at the time of surgery was 34.1 years (interquartile range, 24.1-42.9 years). The mean time to follow-up (±SD) was 2.1 ± 1.5 years. There were 3751 (62.9%) allograft ACLRs using soft tissue, 1188 (19.9%) with Achilles tendon, and 1029 (17.2%) with bone-patellar tendon-bone (BPTB). Graft processing groups included BioCleanse (n = 367), AlloTrue or AlloWash (n = 2278), irradiation greater than 1.8 Mrad (n = 1146), irradiation up to 1.8 Mrad (n = 3637), and no irradiation (n = 1185). There were 156 (2.6%) aseptic revisions. After adjustment for patient age, sex, and BMI, the use of BioCleanse (HR = 2.45; 95% CI, 1.36-4.40) and irradiation greater than 1.8 Mrad (HR = 1.64; 95% CI, 1.08-2.49) were associated with a higher risk of revision when compared with all other methods of processing. BPTB allografts were at higher risk of revision (HR = 1.79; 95% CI, 1.20-2.66) when compared with soft tissue allografts. Conversely, with every 5-year increase in age, the risk of revision was 0.67 (95% CI, 0.61-0.73) times lower. Male patients were found to be at higher risk of revision when compared with females (HR = 1.47; 95% CI, 1.04-2.07). The use of AlloWash or AlloTrue processing, patient BMI, and graft donor age did not affect revision rate significantly. In the largest known study of its kind examining outcome after primary allograft ACLR, graft irradiation greater than 1.8 Mrad, BioCleanse graft processing, younger patient age, male patients, and BPTB allograft were all associated with a higher risk of clinical failure and subsequent revision surgery. © 2015 The Author(s).
Demiryürek, Ebru Ozsezer; Külünk, Safak; Saraç, Duygu; Yüksel, Gözde; Bulucu, Bilinç
2009-08-01
The purpose of this study was to evaluate the effects of different surface treatments on the bond strength of a fiber post to dentin. Sixty extracted human maxillary incisor teeth were manually shaped with K-files using the step-back technique. ISO size 45 files were used as master apical files. Post spaces were prepared and then the root canals were subjected to one of the following 5 surface treatments: irrigation with 5% sodium hypochlorite (NaOCl); treatment with ethanol, ethyl acetate, and acetone-based cleansing agent (Sikko Tim); irrigation with 17% EDTA; etching with 37% orthophosphoric acid for 15 seconds; and etching with 10% citric acid for 15 seconds. Fiber posts were luted using self-etching/self-priming dual polymerized resin cement. From the coronal part of each root, 3 slides of 0.6-mm thickness were obtained. A push-out bond strength test was performed by a universal testing machine at a crosshead speed of 0.5 mm/min. Dentin surfaces were examined under scanning electron microscopy (SEM) after different surface treatments. Data were analyzed with a one-way analysis of variance (ANOVA) and Tukey HSD test. ANOVA revealed that canal surface treatment affected the bond strength (P < .001). The highest bond strength was obtained in the Sikko Tim group. The results also showed that surface treatment methods increased the bond strength to dentin when compared with the control group. Sikko Tim group was the more effective surface treatment agent compared with EDTA, orthophosphoric acid, citric acid, and control groups; however, it could not remove the smear layer and sealer remnants effectively on radicular dentin surfaces. Removal of the smear layer and opening of dentinal tubules are not recommended when a self-etching/self-priming adhesive system is used.
Preventing pressure ulcers in long-term care: a cost-effectiveness analysis.
Pham, Ba'; Stern, Anita; Chen, Wendong; Sander, Beate; John-Baptiste, Ava; Thein, Hla-Hla; Gomes, Tara; Wodchis, Walter P; Bayoumi, Ahmed; Machado, Márcio; Carcone, Steven; Krahn, Murray
2011-11-14
Pressure ulcers are common in many care settings, with adverse health outcomes and high treatment costs. We evaluated the cost-effectiveness of evidence-based strategies to improve current prevention practice in long-term care facilities. We used a validated Markov model to compare current prevention practice with the following 4 quality improvement strategies: (1) pressure redistribution mattresses for all residents, (2) oral nutritional supplements for high-risk residents with recent weight loss, (3) skin emollients for high-risk residents with dry skin, and (4) foam cleansing for high-risk residents requiring incontinence care. Primary outcomes included lifetime risk of stage 2 to 4 pressure ulcers, quality-adjusted life-years (QALYs), and lifetime costs, calculated according to a single health care payer's perspective and expressed in 2009 Canadian dollars (Can$1 = US$0.84). Strategies cost on average $11.66 per resident per week. They reduced lifetime risk; the associated number needed to treat was 45 (strategy 1), 63 (strategy 4), 158 (strategy 3), and 333 (strategy 2). Strategy 1 and 4 minimally improved QALYs and reduced the mean lifetime cost by $115 and $179 per resident, respectively. The cost per QALY gained was approximately $78 000 for strategy 3 and $7.8 million for strategy 2. If decision makers are willing to pay up to $50 000 for 1 QALY gained, the probability that improving prevention is cost-effective is 94% (strategy 4), 82% (strategy 1), 43% (strategy 3), and 1% (strategy 2). The clinical and economic evidence supports pressure redistribution mattresses for all long-term care residents. Improving prevention with perineal foam cleansers and dry skin emollients appears to be cost-effective, but firm conclusions are limited by the available clinical evidence.
The Impact of Strategic Communication on Victory and Defeat in Iraq: 1998-2006
2009-04-03
palatable messages: that our enemy was exclusively Hussein and his supporters, that our focused aims were to maintaining security and regional...historical accounts of biological and chemical weapons, and past accounts of ethnic cleansing . He tied human rights abuses and “his calculated cruelty to his...expulsion of Saddam Hussein, but the benefits of a stable, secular, Iraqi democracy were equally palatable and ultimately more desirable in the long run
Automated Analysis of Renewable Energy Datasets ('EE/RE Data Mining')
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bush, Brian; Elmore, Ryan; Getman, Dan
This poster illustrates methods to substantially improve the understanding of renewable energy data sets and the depth and efficiency of their analysis through the application of statistical learning methods ('data mining') in the intelligent processing of these often large and messy information sources. The six examples apply methods for anomaly detection, data cleansing, and pattern mining to time-series data (measurements from metering points in buildings) and spatiotemporal data (renewable energy resource datasets).
Islam’s Challenge: Jihad and Terrorism
2008-12-12
themselves as the ‘Ikhwan’ or brotherhood. They, like Mohammad who had cleansed the Kaba of its idols, destroyed Sufi shrines and sacred tombs in Mecca and...Medina, including those of the Prophet and his companions. They also destroyed the tomb of Hussain at Karbala, a major Shii holy place, an act...In the Muslim Brotherhood, he quickly emerged as the most important ideologue amid the growing confrontation with the Egyptian regime (Richardson
Apparatus and method for downhole injection of radioactive tracer
Potter, R.M.; Archuleta, J.; Fink, C.F.
The disclosure relates to downhole injection of radioactive /sup 82/Br and monitoring its progress through fractured structure to determine the nature thereof. An ampule containing granular /sup 82/Br is remotely crushed and water is repeatedly flushed through it to cleanse the instrument as well as inject the /sup 82/Br into surrounding fractured strata. A sensor in a remote horehole reads progress of the radioactive material through fractured structure.
Apparatus and method for downhole injection of radioactive tracer
Potter, Robert M.; Archuleta, Jacobo R.; Fink, Conrad F.
1983-01-01
The disclosure relates to downhole injection of radioactive .sup.82 Br and monitoring its progress through fractured structure to determine the nature thereof. An ampule containing granular .sup.82 Br is remotely crushed and water is repeatedly flushed through it to cleanse the instrument as well as inject the .sup.82 Br into surrounding fractured strata. A sensor in a remote borehole reads progress of the radioactive material through fractured structure.
Bacteria on External Fixators: Which Prep is Best?
2012-01-01
aureus (lux). After 12 hours in the broth, a sufficient time to allow biofilm formation ,11 the constructs were individually removed and baseline imaging...difference when cleansing components consisting of stainless steel and alumi- num.15–17 We also found that a simulated external fixator adjustment exposed...Albert E, et al. Direct continuous method for monitoring biofilm infection in a mouse model. Infect Immun. 2003;71: 882–890. 11. Charles CA, Ricotti CA
National Policy and the Post-Systemic Navy
2013-01-01
average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed...5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7...various kinds of good works , ranging from helping stop ethnic cleansing in Kosovo to assisting victims of tsunamis in Indonesia and Japan, not to
1974-08-31
urinary diversion b. Remove temporary/j ermanent collection appliance c. Perform basic sto-A care d. Cleanse /examine cc’Alection device prior to...of micturition d. Determine the type/degree/duration of urethral, vaginal , wound, other urinary outlet discharges e. Determine location/site and...related o. Determine if problem is vaginal /gynacologic p. Determine if problem is scrotal related PERFORMANCE OBJECTIVE (Stimulus) When assigned to
Non-State Actors and their Risks to American Society
2013-03-01
done in house but out of sight of the broader Japanese community.31 The attack was conducted by dispersing the anthrax spores from an elevated...a spiritual cleansing ritual and that the police could not enter. Since Japanese law protects religious freedom and practices, the police departed...created their weapon system in house and their target was the broader Japanese populace. The Tokyo subway system is among the heaviest used subway
Simion, F A; Rhein, L D; Morrison, B M; Scala, D D; Salko, D M; Kligman, A M; Grove, G L
1995-02-01
Epidemiologic studies indicate that after using soaps and other personal care products, many consumers experience irritation. In 50% of the cases the feelings of skin dryness, itching, and stinging occur in the absence of visible signs of irritation. We sought to determine the relation between self-perceived sensory responses of panelists to cleansing products and clinical signs of irritation. A combination of exaggerated arm-washing methods was designed to induce clinical signs of irritation with psychometric techniques developed to quantify sensations. Two studies demonstrated that panelists could reproducibly differentiate between products on the basis of the sensations they felt and that there was a significant correlation (frequently r > 0.80) between these and the observable signs. In the case of skin dryness panelists differentiated products several washing cycles before observable differences were detected. Sensory evaluations of irritation yield additional information on soap and detergent irritancy beyond clinical observations and expand understanding of the irritation process.
Ultrasonic characterization of single drops of liquids
Sinha, D.N.
1998-04-14
Ultrasonic characterization of single drops of liquids is disclosed. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-quality measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities. 5 figs.
Ultrasonic characterization of single drops of liquids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinha, D.N.
Ultrasonic characterization of single drops of liquids is disclosed. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-qualitymore » measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities. 5 figs.« less
Safety Evaluation of Polyethylene Glycol (PEG) Compounds for Cosmetic Use
Shin, Chan Young; Kim, Kyu-Bong
2015-01-01
Polyethylene glycols (PEGs) are products of condensed ethylene oxide and water that can have various derivatives and functions. Since many PEG types are hydrophilic, they are favorably used as penetration enhancers, especially in topical dermatological preparations. PEGs, together with their typically nonionic derivatives, are broadly utilized in cosmetic products as surfactants, emulsifiers, cleansing agents, humectants, and skin conditioners. The compounds studied in this review include PEG/PPG-17/6 copolymer, PEG-20 glyceryl triisostearate, PEG-40 hydrogenated castor oil, and PEG-60 hydrogenated castor oil. Overall, much of the data available in this review are on PEGylated oils (PEG-40 and PEG-60 hydrogenated castor oils), which were recommended as safe for use in cosmetics up to 100% concentration. Currently, PEG-20 glyceryl triisostearate and PEGylated oils are considered safe for cosmetic use according to the results of relevant studies. Additionally, PEG/PPG-17/6 copolymer should be further studied to ensure its safety as a cosmetic ingredient. PMID:26191379
Kennedy, Deborah A.; Cooley, Kieran; Einarson, Thomas R.; Seely, Dugald
2012-01-01
Ionic footbaths are often used in holistic health centres and spas to aid in detoxification; however, claims that these machines eliminate toxins from the body have not been rigorously evaluated. In this proof-of-principle study, we sought to measure the release of potentially toxic elements from ionic footbaths into distilled and tap water with and without feet. Water samples were collected and analyzed following 30-minute ionic footbath sessions without feet using both distilled (n = 1) and tap water (n = 6) and following four ionic footbaths using tap water (once/week for 4 weeks) in six healthy participants. Urine collection samples were analyzed at four points during the study. Hair samples were analyzed for element concentrations at baseline and study conclusion. Contrary to claims made for the machine, there does not appear to be any specific induction of toxic element release through the feet when running the machine according to specifications. PMID:22174728
Stability conditions and mechanism of cream soaps: role of glycerol.
Sagitani, Hiromichi
2014-01-01
Fatty acids, fatty acid potassium soaps, glycerol and water are essential ingredients in the production of stable cream soaps. In this study, the behavior of these components in solution was investigated to elucidate the stability conditions and mechanism of cream soaps. It was determined that the cream soaps were a dispersion of 1:1 acid soap (1:1 molar ratio of potassium soap/fatty acid) crystals in the lamellar gel phase, which has confirmed from the phase behavior diagrams and small angle X-ray scattering data. Glycerol was crucial ingredient in the formation of the lamellar gel phase. The cleansing process of the cream soaps was also evaluated using the same diagrams. The structure of the continuous phase in cream soaps changed from lamellar gel to a micellar aqueous solution upon the addition of water. This structural change during the washing process is important in producing the foaming activity of acid soaps to wash away dirt or excess fats from the skin surface.
Life cycle of a data warehousing project in healthcare.
Verma, R; Harper, J
2001-01-01
Hill Physicians Medical Group (and its medical management firm, PriMed Management) early on recognized the need for a data warehouse. Management demanded that data from many sources be integrated, cleansed, and formatted. As a first step, an operational data store (ODS) was built and populated with data from the main transactional system; encounter data were added. The ODS has served its purpose well and has whetted management's appetite for more information and faster, more reliable access, all in one location. PriMed hired Annams Systems Consulting (Annams) for this effort. A team was formed, made up of consultants from Annams and members of PriMed's information services (IS) team. The "classical" approach is being taken: enhancing the ODS, which is largely normalized in structure, and integrating data from various sources, along with enforcing business rules. The team is designing and implementing data marts and a "star schema" style of data modeling--a useful tool for management to evaluate results before investing further.
Zalis, Michael E; Perumpillichira, James J; Magee, Cordula; Kohlberg, Gavriel; Hahn, Peter F
2006-04-01
To prospectively compare the homogeneity, adequacy, and patient acceptance of nonionic iodine-based regimens with those of a barium-based regimen for computed tomographic (CT) colonography with electronic subtraction cleansing. After institutional review board approval and informed consent were obtained, 68 subjects (41 men (60%) men, 27 (40%) women; mean age, 60 years +/- 6 [standard deviation]) with average or moderate risk factors for development of colorectal carcinoma were recruited and placed into three study groups. Group 1 (n = 25) ingested 150-mL aliquots of 2% barium sulfate suspension with meals and snacks for 48 hours prior to imaging, without other diet modification or a cathartic. Group 2 (n = 21) ingested 10-mL aliquots of nonionic iodinated contrast material (iopromide) with a concentration of 300 mg per milliliter with meals and snacks for 2 days before imaging, without diet modification or a cathartic. Group 3 (n = 22) ingested nonionic iodinated contrast material (iohexol) with a concentration of 300 mg per milliliter with meals and snacks for 2 days before imaging and ingested 34 g of magnesium citrate the evening prior to imaging. CT colonography was also performed on 10 control subjects who ingested polyethylene glycol electrolyte solution prior to imaging. Subjective and numerical measures of bowel preparation quality, homogeneity, and patient comfort among the noncathartic and cathartic cohorts were compared with nonparametric analysis of variance, the Fisher exact test, and the F test, as appropriate. The study was HIPAA compliant. Study subjects who received tagging preparations reported significantly improved discomfort scores when compared with those of the control subjects (P < .05, each comparison). There was no significant difference in discomfort scores among groups 1, 2, and 3. For each reader, scores of subtracted image readability were highest for group 3. Dichotomized rates of preparation "success" were also greatest for group 3. In this series, the patient discomfort scores were significantly improved with tagging preparations for CT colonography. Nonionic iodinated contrast material in conjunction with a hyperosmotic laxative (magnesium citrate) was associated with the best subjective and numerical indices of readability. (c) RSNA, 2006.
A literature review and hypothesis for the etiologies of cervical and root caries.
Grippo, John O; Coleman, Thomas A; Messina, Antonello Maria; Oh, Daniel S
2018-01-18
The presence of endogenous acids from bacteria acting on a suitable substrate combined with sources of exogenous biocorrosives such as exogenous acids and proteolytic enzymes in areas of stress concentration are hypothesized to lead to the development and progression of cervical and root caries (RC). Quantifying the effects of each of the mechanisms (stress and biocorrosion) is a daunting task to investigate since so many factors are involved at various times in the etiology of noncarious cervical lesions (NCCLs), cervical caries (CC), and RC. Frictional action of the tongue has a cleansing effect and lingual serous saliva, which has a high flow rate buffering capacity from bicarbonates seem to account for the paucity of lingual NCCLs, cervical, and RC in these areas of teeth. Future studies are indicated to determine the effects of stress and biocorrosion and their factors in the etiology of CC and RC. This manuscript presents hypothetical and literary information that the combined effects of stress concentration and biocorrosion contribute to the formation as well as progression of cervical and root caries. © 2018 Wiley Periodicals, Inc.
A cross cultural study of vaginal practices and sexuality: implications for sexual health.
Martin Hilber, Adriane; Hull, Terence H; Preston-Whyte, Eleanor; Bagnol, Brigitte; Smit, Jenni; Wacharasin, Chintana; Widyantoro, Ninuk
2010-02-01
Between 2005 and 2006, we investigated vaginal practices in Yogyakarta, Indonesia; Tete, Mozambique; KwaZulu-Natal, South Africa; and Bangkok and Chonburi, Thailand. We sought to understand women's practices, their motivations for use and the role vaginal practices play in women's health, sexuality and sense of wellbeing. The study was carried out among adult women and men who were identified as using, having knowledge or being involved in trade in products. Further contacts were made using snowball sampling. Across the sites, individual interviews were conducted with 229 people and 265 others participated in focus group discussions. We found that women in all four countries have a variety of reasons for carrying out vaginal practices whose aim is to not simply 'dry' the vagina but rather decrease moisture that may have other associated meanings, and that they are exclusively "intravaginal" in operation. Practices, products and frequency vary. Motivations generally relate to personal hygiene, genital health or sexuality. Hygiene practices involve external washing and intravaginal cleansing or douching and ingestion of substances. Health practices include intravaginal cleansing, traditional cutting, insertion of herbal preparations, and application of substances to soothe irritated vaginal tissue. Practices related to sexuality can involve any of these practices with specific products that warm, dry, and/or tighten the vagina to increase pleasure for the man and sometimes for the woman. Hygiene and health are expressions of femininity connected to sexuality even if not always explicitly expressed as such. We found their effects may have unexpected and even undesired consequences. This study demonstrates that women in the four countries actively use a variety of practices to achieve a desired vaginal state. The results provide the basis for a classification framework that can be used for future study of this complex topic. Copyright 2009 Elsevier Ltd. All rights reserved.
Boothby, N; Crawford, J; Halperin, J
2006-01-01
As the use of child soldiers continues to proliferate throughout the world, effective psychosocial interventions must be developed and evaluated. Our research shows that former child soldiers who are provided rehabilitative services and accepted back into their families and communities are able to become productive, responsible and caring adults. In 1988, 39 captured or escaped child soldiers were brought by the Mozambican government to the Lhanguene Rehabilitation Center in Maputo, Mozambique's capital city. Interventions that focused on rehabilitating the children both psychologically and physically were initiated during their 6-month stay at the Lhanguene centre, and reintegration assistance was provided for 2 years thereafter to support their return to families and communities. Our research continued to follow these former child soldiers for 16 years, and focused on their psychological, social and economic functioning. The study included qualitative and quantitative data collection methods to obtain adult well-being outcomes and was also designed to identify interventions that enabled these child soldiers to re-enter civilian life and lead relatively productive lives. Efficacious rehabilitation activities included those that strengthened individuals' coping skills for anticipated trauma and grief, instilled a sense of social responsibility and promoted self-regulation and security (versus survival) seeking behaviour. Activities that supported long term reintegration and self-sufficiency included community acceptance and forgiveness, traditional cleansing and healing rituals, livelihoods and apprenticeships.
Wright, Richard L.; Zillmer, Ruediger; Biran, Adam; Hall, Peter; Sidibe, Myriam
2015-01-01
We evaluated the utility of electronic loggers to measure the effects of a simple intervention designed to influence the rates of hand washing with soap within enclosed toilets and bathrooms in low-income urban households in Kerala, India. 58 households were given three items with embedded electronic loggers for a period of 2-5 days. Two logged soaps tracked hand and body washing in the bathroom. The third logged item was a water vessel used for flushing the toilet and for post-defecation anal cleansing; this served as a marker of toilet use. In addition, 28 households in a Soap by toilet arm were given an additional logged soap, to be kept by the toilet, and used for hand washing. Compared with the Soap in bathroom arm, the loggers in the Soap by toilet households recorded 73% greater daily use of soaps designated for hand washing (t(36)=2.92, p<0.01) and 172% greater use within 2 minutes of the use of the water vessel (t(36)=3.51, p = 0.001). We conclude that the loggers were capable of detecting changes in the rates of hand washing with soap and changes in hand washing with soap after use of the toilet. Further adoption of logger technologies would enable more insightful studies of hand washing within urban environments. PMID:26101886
Wright, Richard L; Zillmer, Ruediger; Biran, Adam; Hall, Peter; Sidibe, Myriam
2015-01-01
We evaluated the utility of electronic loggers to measure the effects of a simple intervention designed to influence the rates of hand washing with soap within enclosed toilets and bathrooms in low-income urban households in Kerala, India. 58 households were given three items with embedded electronic loggers for a period of 2-5 days. Two logged soaps tracked hand and body washing in the bathroom. The third logged item was a water vessel used for flushing the toilet and for post-defecation anal cleansing; this served as a marker of toilet use. In addition, 28 households in a Soap by toilet arm were given an additional logged soap, to be kept by the toilet, and used for hand washing. Compared with the Soap in bathroom arm, the loggers in the Soap by toilet households recorded 73% greater daily use of soaps designated for hand washing (t(36)=2.92, p<0.01) and 172% greater use within 2 minutes of the use of the water vessel (t(36)=3.51, p = 0.001). We conclude that the loggers were capable of detecting changes in the rates of hand washing with soap and changes in hand washing with soap after use of the toilet. Further adoption of logger technologies would enable more insightful studies of hand washing within urban environments.
Colour stability of maxillofacial silicone elastomers: a review of the literature.
Kulkarni, R S; Nagda, S J
2014-09-01
Colour degradation is a serious limitation of maxillofacial silicone elastomers and most silicone facial prostheses have to be remade within 1 year due to colour deterioration. A comprehensive review of the literature was completed using MEDLINE and PubMed Library databases. This was supplemented with a manual search of selected journals and textbooks. English language articles published in peer-reviewed journals from 1966 to January 2012 in which colour stability of silicone elastomers was evaluated using standard research protocols were included. In all, 127 articles were identified and 23 met the inclusion criteria. Current literature reveals that average colour stability of maxillofacial silicone prostheses is 6-12 months, and inherent unstable nature of silicones is responsible for the color degradation. Opacifiers, oil pigments and inorganic colourants may have a protective effect on colour stability of prostheses. Organic colourants, ultraviolet (UV) light, cleansing solutions, dust and aging can adversely affect colour stability of silicone prostheses. A direct comparison between studies has not been possible, because of the differences in experimental set-up such as materials tested, colourants used, or method of aging. There appears to be a need for a standardised test protocol for colour stability of maxillofacial materials. Colour degradation limits the useful lifespan of maxillofacial silicones. Improvements in colour stability is possible with the use of certain nano opacifiers, UV absorbers, photoprotective agents, and use of inorganic pigments and metal oxides.
Better vacuum by removal of diffusion-pump-oil contaminants
NASA Technical Reports Server (NTRS)
Buggele, A. E.
1975-01-01
The complex problem of why large space simulation chambers do not realize true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance were identified, and some advances in vacuum distillation-fractionation technology were achieved which resulted in a two-decade-or-more lower ultimate pressure. Data are presented to show the overall or individual contaminating effects of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and for reclaiming contaminated oil by high-vacuum molecular distillation are described. Conceptual self-cleansing designs and operating procedures are proposed for modifying large diffusion pumps into high-efficiency distillation devices. The potential exists for application of these technological advancements to other disciplines, such as medicine, biomedical materials, metallurgy, refining, and chemical (diffusion-enrichment) processing.
Saini, Rajesh; Kotian, Ravindra; Madhyastha, Prashanthi; Srikant, N
2016-01-01
The objective of this study was to compare the sorption and solubility of heat-cure and self-cure acrylic resins in different solutions. One heat-cure acrylic resin (Trevalon) and one self-cure acrylic resin (Rapid Repair) were studied. Five groups of square-shaped specimens (20 mm × 20 mm × 2 mm) were prepared for each acrylic resin and then immersed in five solutions: distilled water, artificial saliva, denture cleansing solution, distilled water, and denture cleaning solution for 12 h alternatively, artificial saliva and denture cleaning solution for 12 h alternatively at 37 ± 2°C, and tested sorption and solubility by weight gain/loss method, respectively, after 1, 6, and 11 weeks. The data were analyzed by one-way analysis of variance followed by post hoc Tukey's test. Water sorption mean values varied from 17.5 ± 0.88 to 27.25 ± 1.04 μg/mm 3 for heat cure and from 12.75 ± 0.55 to 19.75 ± 1.04 μg/mm 3 for self-cure in the different solutions after different interval periods of 1, 6, and 11 weeks. These values were statistically significant (P< 0.001). Water solubility mean values varied from 0.25 ± 0.55 to 1.5 ± 0.55 μg/mm 3 for heat cure and from 1.5 ± 0.55 to 6.5 ± 0.55 μg/mm 3 for self-cure in the different solutions after different interval periods of 1, 6, and 11 weeks. These values were statistically not significant (P > 0.05). There was no linear correlation between sorption and solubility values. Overall, analysis of results showed the maximum sorption value in denture cleansing solution followed by alternative soaking in distilled water and artificial saliva. Least sorption was observed with artificial saliva followed by distilled water. Both heat-cure and self-cure acrylic resins showed varying water sorption and solubility. The results of both water sorption and solubility showed compliance with the International Standards Organization specification. No correlation was found between water sorption and solubility. Artificial saliva solution is a better storage medium than distilled water and denture cleansing solution for both heat-cure and self-cure acrylic resins.
Impact of the 20th Century War on Democratic Serbia Today
2012-03-21
Zagreb . On April 12th, they entered Belgrade by simultaneous attacks from Bulgaria, Romania, and Austria, and by April 17th, Yugoslavia had capitulated...and it was in Zagreb that preparation for cultural assimilation, persecution and ethnic cleansing occurred.59 Hitler did not want the Balkans as... Zagreb , but Ustaša and German pressure forced him to move into Serbian territory, nearby Belgrade. This move brought Tito into conflict with Mihailović
Answering AL-QAEDA: The Battle for Hearts and Minds in the Middle East
2003-05-01
involvement with Arafat, while the Secretary of Defense and the Vice President’s Office have argued against launching a political process while violence ...to the reports of Saddam’s brutality against women and children in the marshy south. The best estimate we have then is that roughly 135,000 to...following Serb violence and repression against Albanian Moslems, NATO began Operation ALLIED FORCE to end Serb ethnic cleansing in Kosovo. In a 78-day
Transplantation of Cadaver Tissues and Organs. Part 15. Chapter 338
1984-01-09
different individuals should preferentially be nonviable and cleansed * •of cellular debris. * N moral and legal issues most often surround the...there is a minority who view such a position as immoral,that the individual expires only when all vegetative function ceases. 3 i Ii i ŕ " Donald J...Drug Adminstration in 1982 has ruled processed bone * as a "device", which qualifies under the Federal Food, Drug and Cosmetic Act, Medical Device
A specialist team of A&E doctors and nurses establish emergency care units in Kosovo.
Hodgetts, Lieutenant Colonel Tim; Kenward, Gary
2000-02-01
On June 12, 1999 NATO troops led by British paratroopers of 5 Airborne Brigade entered Kosovo and secured key military sites. This multinational operation (code named 'OP AGRICOLA') was in response to the ethnic cleansing of Kosovo-Albanians, and followed a sustained period of aerial attack in Kosovo and Serbia. The ground operation required substantial medical support, and the British hospital element was provided by 22 Field Hospital RAMC.
Debridement Techniques in Pediatric Trauma and Burn-Related Wounds
Block, Lisa; King, Timothy W.; Gosain, Ankush
2015-01-01
Significance: Traumatic injuries are the leading cause of morbidity and mortality in children. The purpose of this review is to provide an overview of the initial assessment and management of traumatic and burn wounds in children. Special attention is given to wound cleansing, debridement techniques, and considerations for pain management and psychosocial support for children and families. Recent Advances: Basic and translational research over the last 5–7 years has advanced our knowledge related to the optimal care of acute pediatric traumatic and burn wounds. Data concerning methods, volume, solution and timing for irrigation of acute traumatic wounds, timing and methods of wound debridement, including hydrosurgery and plasma knife coblation, and wound dressings are presented. Additionally, data concerning the long-term psychosocial outcomes following acute injury are presented. Critical Issues: The care of pediatric trauma and burn-related wounds requires prompt assessment, pain control, cleansing, debridement, application of appropriate dressings, and close follow-up. Ideally, a knowledgeable multidisciplinary team cares for these patients. A limitation in the care of these patients is the relative paucity of data specific to the care of acute traumatic wounds in the pediatric population. Future Directions: Research is ongoing in the arenas of new debridement techniques and instruments, and in wound dressing technology. Dedicated research on these topics in the pediatric population will serve to strengthen and advance the care of pediatric patients with acute traumatic and burn wounds. PMID:26487978
Kulthanan, Kanokvalai; Nuchkull, Piyavadee; Varothai, Supenya
2013-07-01
Patients with atopic dermatitis (AD) have increased susceptibility to irritants. Some patients have questions about types of water for bathing or skin cleansing. We studied the pH of water from various sources to give an overview for physicians to recommend patients with AD. Water from various sources was collected for measurement of the pH using a pH meter and pH-indicator strips. Bottled drinking still water had pH between 6.9 and 7.5 while the sparkling type had pH between 4.9 and 5.5. Water derived from home water filters had an approximate pH of 7.5 as same as tap water. Swimming pool water had had pH between 7.2 and 7.5 while seawater had a pH of 8. Normal saline and distilled water had pH of 5.4 and 5.7, respectively. Facial mineral water had pH between 7.5 and 8, while facial makeup removing water had an acidic pH. Normal saline, distilled water, bottled sparkling water and facial makeup removing water had similar pH to that of normal skin of normal people. However, other factors including benefits of mineral substances in the water in terms of bacteriostatic and anti-inflammation should be considered in the selection of cleansing water.
What's growing on your stethoscope? (And what you can do about it).
Schroeder, Ariel; Schroeder, Maryellen A; D'Amico, Frank
2009-08-01
Studies have shown that rubbing alcohol pads on stethoscope diaphragms can reduce bacterial colonization, but alcohol pads are used infrequently used and not always available. We conducted a prospective, single-blinded study to investigate whether simultaneously scrubbing hands and stethoscope head with alcohol-based hand foam would significantly reduce bacterial counts on the stethoscope. Using their own stethoscope, participants imprinted the stethoscope head onto a chocolate agar plate, then used alcohol-based hand foam to cleanse their hands while simultaneously rubbing the stethoscope head. Once the stethoscope heads were dry, the participants imprinted their stethoscope heads onto a second plate. After 48 hours' incubation, we determined the bacterial counts for the prewash and post-wash plates, and compared the 2. We analyzed a total of 184 cultures (from 92 stethoscopes). Both the mean (28 prewash vs 3 post-wash, P=.001) and median (11 prewash vs 1 post-wash, P=.001) colony counts were significantly greater before being cleansed. Three methicillin-resistant Staphylococcus aureus (MRSA) colonies were identified in the prewash period; all were destroyed by the foam. The estimated number of hand washes needed to prevent 1 MRSA colony is 31 (95% confidence interval [CI], 18-89). Simultaneously using hand foam to clean hands and stethoscope heads reduces bacterial counts on stethoscopes. Further research is needed to determine whether this intervention can reduce morbidity and mortality associated with bacterial infection.
Kulthanan, Kanokvalai; Varothai, Supenya
2013-01-01
Background Patients with atopic dermatitis (AD) have increased susceptibility to irritants. Some patients have questions about types of water for bathing or skin cleansing. Objective We studied the pH of water from various sources to give an overview for physicians to recommend patients with AD. Methods Water from various sources was collected for measurement of the pH using a pH meter and pH-indicator strips. Results Bottled drinking still water had pH between 6.9 and 7.5 while the sparkling type had pH between 4.9 and 5.5. Water derived from home water filters had an approximate pH of 7.5 as same as tap water. Swimming pool water had had pH between 7.2 and 7.5 while seawater had a pH of 8. Normal saline and distilled water had pH of 5.4 and 5.7, respectively. Facial mineral water had pH between 7.5 and 8, while facial makeup removing water had an acidic pH. Conclusion Normal saline, distilled water, bottled sparkling water and facial makeup removing water had similar pH to that of normal skin of normal people. However, other factors including benefits of mineral substances in the water in terms of bacteriostatic and anti-inflammation should be considered in the selection of cleansing water. PMID:23956962
Tozer, Sarah A; Kelly, Seamus; O'Mahony, Cian; Daly, E J; Nash, J F
2015-09-01
Realistic estimates of chemical aggregate exposure are needed to ensure consumer safety. As exposure estimates are a critical part of the equation used to calculate acceptable "safe levels" and conduct quantitative risk assessments, methods are needed to produce realistic exposure estimations. To this end, a probabilistic aggregate exposure model was developed to estimate consumer exposure from several rinse off personal cleansing products containing the anti-dandruff preservative zinc pyrithione. The model incorporates large habits and practices surveys, containing data on frequency of use, amount applied, co-use along with market share, and combines these data at the level of the individual based on subject demographics to better estimate exposure. The daily-applied exposure (i.e., amount applied to the skin) was 3.79 mg/kg/day for the 95th percentile consumer. The estimated internal dose for the 95th percentile exposure ranged from 0.01-1.29 μg/kg/day after accounting for retention following rinsing and dermal penetration of ZnPt. This probabilistic aggregate exposure model can be used in the human safety assessment of ingredients in multiple rinse-off technologies (e.g., shampoo, bar soap, body wash, and liquid hand soap). In addition, this model may be used in other situations where refined exposure assessment is required to support a chemical risk assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Reduction of halo pin site morbidity with a new pin care regimen.
Kazi, Hussain Anthony; de Matas, Marcus; Pillay, Robin
2013-06-01
A retrospective analysis of halo device associated morbidity over a 4-year period. To assess the impact of a new pin care regimen on halo pin site related morbidity. Halo orthosis treatment still has a role in cervical spine pathology, despite increasing possibilities of open surgical treatment. Published figures for pin site infection range from 12% to 22% with pin loosening from 7% to 50%. We assessed the outcome of a new pin care regimen on morbidity associated with halo spinal orthoses, using a retrospective cohort study from 2001 to 2004. In the last two years, our pin care regimen was changed. This involved pin site care using chlorhexidene & regular torque checking as part of a standard protocol. Previously, povidone iodine was used as skin preparation in theatre, followed by regular sterile saline cleansing when pin sites became encrusted with blood. There were 37 patients in the series, the median age was 49 (range, 22-83) and 20 patients were male. The overall infection rate prior to the new pin care protocol was 30% (n=6) and after the introduction, it dropped to 5.9% (n=1). This difference was statistically significant (p<0.05). Pin loosening occurred in one patient in the group prior to the formal pin care protocol (3%) and none thereafter. Reduced morbidity from halo use can be achieved with a modified pin cleansing and tightening regimen.
Striving for the moral self: the effects of recalling past moral actions on future moral behavior.
Jordan, Jennifer; Mullen, Elizabeth; Murnighan, J Keith
2011-05-01
People's desires to see themselves as moral actors can contribute to their striving for and achievement of a sense of self-completeness. The authors use self-completion theory to predict (and show) that recalling one's own (im)moral behavior leads to compensatory rather than consistent moral action as a way of completing the moral self. In three studies, people who recalled their immoral behavior reported greater participation in moral activities (Study 1), reported stronger prosocial intentions (Study 2), and showed less cheating (Study 3) than people who recalled their moral behavior. These compensatory effects were related to the moral magnitude of the recalled event, but they did not emerge when people recalled their own positive or negative nonmoral behavior (Study 2) or others' (im)moral behavior (Study 3). Thus, the authors extend self-completion theory to the moral domain and use it to integrate the research on moral cleansing (remunerative moral strivings) and moral licensing (relaxed moral strivings).
Draelos, Zoe; Hornby, Sidney; Walters, Russel M; Appa, Yohini
2013-12-01
The addition of hydrophobically modified polymers (HMPs) to cleansers that contain surfactants can create polymer-surfactant complexes that are less irritating to the skin than commercially available mild cleansers. Our objective was to compare the tolerability and efficacy of a test foaming liquid facial cleanser containing HMPs with a commercial liquid nonfoaming facial cleanser in women with sensitive skin. In this randomized, prospective, double-blind, comparative study, women (n = 20 per group) with mild-to-moderate atopic dermatitis (AD), eczema, acne, or rosacea used a test gentle foaming liquid facial cleanser containing HMPs or a commercial gentle liquid nonfoaming facial cleanser daily for 3 weeks. Investigators assessed irritation and skin condition. Study subjects also assessed their skin properties and the performance of each cleanser. Clinicians as well as study subjects consistently rated the test cleanser as effective or slightly more effective at improving symptoms than the commercial cleanser, although no significant differences between groups were observed. At weeks 1 and 3, respectively, more users of the commercial cleanser reported irritation (20% and 10%) than users of the test cleanser (5% and 5%). In addition, subject self-assessments of skin condition and cleansing properties were slightly more improved with the test cleanser than with the commercial cleanser. Both the test foaming cleanser containing HMPs and the commercial nonfoaming cleanser were effective and well accepted by most women in the study. Improvements were observed by both clinicians and subjects in the group using the test cleanser containing HMPs in all evaluated skin categories. © 2013 The Authors Journal of Cosmetic Dermatology Published by Wiley Periodicals, Inc.
Bellantone, R; Pacelli, F; Sofo, L; Doglietto, G B; Bossola, M; Ratto, C; Crucitti, F
1988-01-01
A prospective randomized study was performed with 65 patients undergoing elective surgery for colorectal cancer, to evaluate the prophylactic effect of two different parenteral antibiotic regimens. All patients underwent rigorous mechanical cleansing of the bowel (enemas, laxatives), received low-residue diet 3 days pre-operatively, and were given oral metronidazole (250 mg) five times a day for 3 days preoperatively. They were divided into two groups comparable in age, nutritional status and operative procedure. The patients in group A (36) received 2 g i.v. of cefotetan at induction of anaesthesia and two other administrations every 12 h. Patients in group B (29) were given clindamicin (600 mg, i.v.) at induction of anaesthesia plus aztreonam (1 g, i.v.); two other doses of the same combined antibiotics were administered every 8 h. Five patients were excluded from the study because they underwent Miles procedure; two others because they underwent explorative laparotomy only. The overall incidence of post-operative septic complications was 6.9% (4/58). No significant differences were found in terms of the rate of surgical infections: 3.1 in group A (1/32) and 0% in group B. Urinary tract infections (1 case) and respiratory tract infections (2 cases) were observed only in group B: the rate was found to be 11.5% (3/26); two anastomotic leakages were observed in group A (6.25%) and one in group B (3.8%). These data suggest that cefotetan appears to be as effective as clindamicin plus aztreonam in prophylaxis against infection in elective colorectal surgery.
Cho, JeongHyeon; Lee, SeungHee; Shin, Jung A; Kim, Jeong Ho; Lee, Hong Sub
2017-01-01
Background/Aims Few studies have evaluated the use of a smartphone application (app) for educating people undergoing colonoscopy and optimizing bowel preparation. Therefore, this study was designed to develop a smartphone app for people to use as a preparation guide and to evaluate the efficacy of this app when used prior to colonoscopy. Methods In total, 142 patients (male:female=84:58, mean age=43.5±9.3 years), who were scheduled to undergo a colonoscopy at Myongji Hospital, were enrolled in this study. Seventy-one patients were asked to use a smartphone app that we had recently developed to prepare for the colonoscopy, while the 71 patients of the sex and age-matched control group were educated via written and verbal instructions. Results The quality of bowel cleansing, evaluated using the Boston Bowel Preparation Scale, was significantly higher in the smartphone app group than in the control group (7.70±1.1 vs. 7.24±0.8, respectively, p=0.007 by t-test). No significant differences were found between the two groups regarding work-up time and the number of patients with polyps. Conclusions In this study, targeting young adults (≤50 years), the bowel preparation achieved by patients using the smartphone app showed significantly better quality than that of the control group. PMID:28669148
Translations on Eastern Europe. Political, Sociological, and Military Affairs, Number 1461
1977-10-17
traditional and other social determinants. This at once amounts to a strict rejection of such theories as, for instance, advocated by Kelsen , in his "Pure...1975, pp 334 ff. 5. As to the pure law doctrine, H. Kelsen would like it understood as "a pure law theory, that is to say, cleansed of all political...ideology and all natural science elements" (cf. H. Kelsen , "Reine Rechtslehre," Vienna, 1960, preface). For a criticism of Kelsen’s legal positivism
Hospital Casemix Protocol - Medibank Private Perspective.
Szakiel, John
2010-06-01
Hospital Casemix Protocol data provide a brief summary outlining morbidity data and costs associated with an episode of care. Federal government legislation requires that hospitals report this information to private health insurers who, in turn, merge these data with benefit outlays and report their findings to the Department of Health and Ageing (DoHA). This article gives a brief outline of the collection, cleansing and processing of these data and subsequent reporting to DoHA by Medibank Private, which accounts for approximately 30% of collected data.
Chemical Composition of the Atmosphere
NASA Astrophysics Data System (ADS)
Schlager, Hans; Grewe, Volker; Roiger, Anke
Atmospheric trace gases have an important impact on Earth's radiative budget, the oxidative or cleansing ability of the atmosphere, the formation, growth and properties of aerosols, air quality, and human health. During recent years, the coupling between atmospheric chemistry and climate has received particular attention. Therefore, research is now focused on the composition and processes in the upper troposphere and lower stratosphere, a key region in this respect. In this chapter the chemical composition of the atmosphere is addressed and selected examples of significant advances in this field are presented.
NASA Technical Reports Server (NTRS)
1994-01-01
The Aqualizer is designed to cleanse water with minimal use of chemicals by stabilizing the ions in the water. Its applications are both recreational and industrial. A non-electrical passive device, the Aqualizer operates on the principle of catalytic water conditioning. It consists of a stainless steel pipe length with a helical core and is offered in a variety of sizes depending on the quantity of water to be treated. The device is based on NASA silver ionization technology used to purify drinking water aboard the Apollo spacecraft.
Surfactant irritation: in vitro corneosurfametry and in vivo bioengineering.
Gabard, B; Chatelain, E; Bieli, E; Haas, S
2001-02-01
Irritant reactions to surfactants, cleansing products, soaps and detergents are common in clinical and occupational dermatology. Mildness has become a major benefit claimed, and testing for mildness now ranks among the first concerns of the manufacturing industry. A wealth of publications deals with this problem, trying to improve the methodology, reduce the costs of testing and facilitate decision-making. Differences in vivo can be measured clinically and/or instrumentally. This is difficult, as commercially available products are generally safe to use and none are harsh in the absolute sense. Nineteen different products (syndets, shampoos, personal cleansers), all claiming to be mild, were tested in vitro by a newly introduced method, corneosurfametry. For evaluating the aggressiveness of the products, the calculation of an index of irritation (IOI) was proposed. A concentration-effect curve of sodium lauryl sulfate (SLS) as standard and model surfactant was obtained. Some of the products were further tested in vivo with a flex wash test and with a soap chamber test and compared to SLS. Bioengineering methods (transepidermal water loss TEWL, skin color) were used to evaluate the results. The results of the corneosurfametry allowed us to classify the products in three categories, with increasing aggressiveness towards the stratum corneum, according to their IOIs. The in vivo tests were not able to discriminate between the products, but ranks from the results of the bioengineering measurements showed a good correlation between TEWL changes, but not between colour changes, and IOIs from corneosurfametry. Corneosurfametry emerged as a simple, low-cost and fast method for ranking commercial products according to their mildness. However, the skin bioengineering techniques showed that some products could lead to skin reactions, such as erythema, that could not be detected by the in vitro technique.
Sol-gel derived bioactive coating on zirconia: Effect on flexural strength and cell proliferation.
Shahramian, Khalil; Leminen, Heidi; Meretoja, Ville; Linderbäck, Paula; Kangasniemi, Ilkka; Lassila, Lippo; Abdulmajeed, Aous; Närhi, Timo
2017-11-01
The purpose of this study was to evaluate the effect of sol-gel derived bioactive coatings on the biaxial flexural strength and fibroblast proliferation of zirconia, aimed to be used as an implant abutment material. Yttrium stabilized zirconia disc-shaped specimens were cut, ground, sintered, and finally cleansed ultrasonically in each of acetone and ethanol for 5 minutes. Three experimental groups (n = 15) were fabricated, zirconia with sol-gel derived titania (TiO 2 ) coating, zirconia with sol-gel derived zirconia (ZrO 2 ) coating, and non-coated zirconia as a control. The surfaces of the specimens were analyzed through images taken using a scanning electron microscope (SEM), and a non-contact tapping mode atomic force microscope (AFM) was used to record the surface topography and roughness of the coated specimens. Biaxial flexural strength values were determined using the piston-on-three ball technique. Human gingival fibroblast proliferation on the surface of the specimens was evaluated using AlamarBlue assay™. Data were analyzed using a one-way analysis of variance (ANOVA) followed by Tukey's post-hoc test. Additionally, the biaxial flexural strength data was also statistically analyzed with the Weibull distribution. The biaxial flexural strength of zirconia specimens was unaffected (p > 0.05). Weibull modulus of TiO 2 coated and ZrO 2 coated groups (5.7 and 5.4, respectively) were lower than the control (8.0). Specimens coated with ZrO 2 showed significantly lower fibroblast proliferation compared to other groups (p < 0.05). In conclusion, sol-gel derived coatings have no influence on the flexural strength of zirconia. ZrO 2 coated specimens showed significantly lower cell proliferation after 12 days than TiO 2 coated or non-coated control. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2401-2407, 2017. © 2016 Wiley Periodicals, Inc.
Del Fabbro, Massimo; Afrashtehfar, Kelvin Ian; Corbella, Stefano; El-Kabbaney, Ahmed; Perondi, Isabella; Taschieri, Silvio
2018-03-01
This systematic review evaluated the effectiveness of nickel-titanium (NiTi) rotary files compared to stainless-steel (SST) hand files. An electronic search was performed on Medline, EMBASE, CENTRAL and Scopus databases up to February 2016. An additional hand searching was performed in 13 journals. The studies were classified according to study type and the outcome variables. Two reviewers independently applied eligibility criteria, extracted data, and three reviewers independently assessed the quality of the evidence of each included study according to The Cochrane Collaboration's procedures. A meta-analysis was performed whenever it was possible. The electronic and hand search strategies yielded 1155 references of studies after removal of duplicates. Four clinical studies (two prospective and two retrospective studies) and 18 in vitro studies (on extracted teeth) were included for the qualitative synthesis after full-text evaluation of the eligible studies. The overall level of methodological quality of the studies included can be considered inadequate. Only one clinical study was judged at low risk of bias, whereas most non-clinical studies had a low risk of bias. Three meta-analyses, based on a very limited number of studies, could be performed. Each meta-analysis contained two studies. Of these, one meta-analysis was based on clinical studies. The results of this systematic review suggested that NiTi rotary instruments were associated with lower canal transportation and apical extrusion when compared to SST hand files, whereas both groups had similar outcomes in terms of success of therapy, amount of residual bacteria, and cleansing ability after treatment. However, due to the limited evidence available, these results should be interpreted with caution. Consequently, more randomized control trials using standardized protocols are needed in order to provide more solid recommendations. Copyright © 2017 Elsevier Inc. All rights reserved.
Mackuľak, Tomáš; Mosný, Michal; Škubák, Jaroslav; Grabic, Roman; Birošová, Lucia
2015-03-01
In this study we analyzed and characterized 29 psychoactive remedies, illicit drugs and their metabolites in single stages of wastewater treatment plants in the capital city of Slovakia. Psychoactive compounds were present within all stages, and tramadol was detected at a very high concentration (706 ng/L). Significant decreases of codeine, THC-COOH, cocaine and buprenorphine concentration were observed in the biological stage. Consequently, we were interested in the possibility of alternative tertiary post-treatment of effluent water with the following aquatic plants: Cabomba caroliniana, Limnophila sessiliflora, Egeria najas and Iris pseudacorus. The most effective plant for tertiary cleansing was I. pseudacorus which demonstrated the best pharmaceutical removal capacity. After 48 h codeine and citalopram was removed with 87% efficiency. After 96 h were all analyzed compounds were eliminated with efficiencies above 58%. Copyright © 2015 Elsevier B.V. All rights reserved.
Automated Data Cleansing in Data Harvesting and Data Migration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Mark; Vowell, Lance; King, Ian
2011-03-16
In the proposal for this project, we noted how the explosion of digitized information available through corporate databases, data stores and online search systems has resulted in the knowledge worker being bombarded by information. Knowledge workers typically spend more than 20-30% of their time seeking and sorting information, only finding the information 50-60% of the time . This information exists as unstructured, semi-structured and structured data. The problem of information overload is compounded by the production of duplicate or near-duplicate information. In addition, near-duplicate items frequently have different origins, creating a situation in which each item may have unique informationmore » of value, but their differences are not significant enough to justify maintaining them as separate entities. Effective tools can be provided to eliminate duplicate and near-duplicate information. The proposed approach was to extract unique information from data sets and consolidation that information into a single comprehensive file.« less
Harpin, V A; Rutter, N
1985-01-01
The effect of increasing the humidity in incubators was examined in 62 infants of less than 30 weeks' gestation. Thirty three infants nursed in high humidity for two weeks were compared retrospectively with 29 infants from an earlier study who were nursed under plastic bubble blankets or with topical paraffin but without raised humidity. Humidification reduced skin water loss and improved maintenance of body temperature from birth, but did not delay the normal postnatal maturation of the skin. Infants nursed without humidity frequently became hypothermic in spite of a high incubator air temperature. These advantages must be weighed against the finding that overheating was more common and Pseudomonas was more commonly isolated from the infants. It is recommended that incubator humidity is raised for babies under 30 weeks' gestation in the first days of life but meticulous attention should be paid to fluid balance, avoiding overheating, and cleansing of the humidifier reservoir. PMID:3985653
Davies, R H; Wray, C
1996-05-01
A study of the dissemination of Salmonella enteritidis in the poultry breeder industry in the UK showed that the choice of sites for sampling the environment of occupied houses and empty houses which had been disinfected after depopulation had a significant influence on the outcome. Increased isolation rates could be achieved by sampling nest box floors and dust in open slave feed hoppers in occupied poultry houses. Nest box floors were the most sensitive sites for detection of residual environmental contamination in poultry houses where enrofloxacin treatment had been used. Floor sweepings, nest box floors, slave feed hoppers, hydrated wall fabric junctions and high beams and pipes were the most sensitive sample sites in cleansed and disinfected poultry houses. The use of universal disinfectant neutralisers gave good results in laboratory trials but appeared to reduce the isolation rate from field samples.
Safety of oral sulfates in rats and dogs contrasted with phosphate-induced nephropathy in rats.
Pelham, Russell W; Russell, Robert G; Padgett, Eric L; Reno, Frederick E; Cleveland, Mark vB
2009-01-01
An oral sulfate salt solution (OSS), under development as a bowel cleansing agent for colonoscopy in humans, is studied in rats and dogs. In rats, amaximumpractical oral OSS dose (5 g/kg/d) is compared with an oral sodium phosphate (OSP) solution, both at about 7 times the clinical dose. OSS induces the intended effects of loose stools and diarrhea. In rats, higher urine sodium and potassium accompany higher clearance rates, considered adaptive to the osmotic load of OSS. OSS for 28 days is well tolerated in rats and dogs. In contrast, OSP causes increased mortality, reduced body weight and food consumption, severe kidney tubular degeneration, and calcium phosphate deposition in rats. These are accompanied by mineralization in the stomach and aorta, along with cardiac and hepatic degeneration and necrosis. The greater safety margin of OSS over OSP at similarmultiples of the clinical dose indicates its suitability for human use.
Thompson, Alex; Reader, Sandie; Field, Emma; Shephard, Adrian
2013-06-01
Acute sore throat (pharyngitis) is one of the most common illnesses for which children are seen by primary care physicians. Most cases are caused by viruses and are benign and self-limiting. Clinically proven, over-the-counter throat lozenges provide rapid and effective relief of acute sore throat symptoms, and are increasingly important in self-management of this condition. The purpose of this study (International Standard Randomized Controlled Trial Number: ISRCTN34958871) was to evaluate the acceptability of two licensed, commercially available sore throat lozenges containing amylmetacresol and 2,4-dichlorobenzyl (AMC/DCBA)--one strawberry flavored and the other orange flavored--in healthy children. This was an open-label, single-dose, crossover, taste-testing study in children recruited via a clinical database and advertisements over a 3.5-week period. Potentially eligible participants were invited to attend the taste-testing session at a clinic. At the screening session, which took place either before or on the day of taste testing, details of relevant medical history, medication, and demographics were recorded. Of the 108 screened subjects, 102 were recruited. These were healthy male and female children aged 6-12 years. Each child cleansed their palate with water and water biscuits before tasting a strawberry-flavored lozenge (Strepsils® strawberry sugar free, Reckitt Benckiser Healthcare Limited, Nottingham, UK; PL 00063/0395), which was sucked for 1 minute and then expelled. The orange-flavored lozenge (Strepsils® orange with vitamin C, Reckitt Benckiser Healthcare Limited, Nottingham, UK; PL 016242152) was tasted at least 15 minutes later following further cleansing of the palate. The spontaneous reaction of the child on tasting each lozenge was observed and recorded. Subjects were asked to indicate their liking for each lozenge, using a 7-point hedonic facial scale, and were required to answer a series of questions relating to what they liked and disliked about the taste and the feel of the lozenge in the mouth and throat. The primary endpoint was the proportion of subjects with a hedonic facial score of >4. Secondary endpoints included the spontaneous reaction of the child on tasting the lozenge and responses to questions related to taste. The taste of the lozenge was scored >4 (i.e. 'good', 'really good', or 'super good') by 85.3% of subjects for the strawberry flavor and 49.0% for the orange flavor (p < 0.0001). The mean (standard deviation) score was 5.72 (1) for the strawberry-flavored lozenge and 4.35 (2) for the orange-flavored lozenge. The proportion of subjects willing to take the lozenge again was 94% for the strawberry flavor and 56% for the orange flavor. Strawberry-flavored AMC/DCBA lozenges were liked by, and acceptable to, the majority of the children. AMC/DCBA orange-flavored lozenges were also liked by, and acceptable to, approximately half the children. Overall, both strawberry and orange would be suitable flavors for lozenges intended for children when they suffer from sore throat.
Gralnek, I M; Adler, S N; Yassin, K; Koslowsky, B; Metzger, Y; Eliakim, R
2008-04-01
Esophageal capsule endoscopy (ECE) provides an alternative, minimally invasive modality for evaluating the esophagus. This study evaluates the performance and test characteristics of a second-generation esophageal capsule endoscope, the PillCam ESO 2. Adults with known or suspected esophageal disease were included. Using the simplified ingestion procedure, each patient underwent capsule endoscopy with the PillCam ESO 2. Following ECE, esophagogastroduodenoscopy (EGD) was performed on the same day by an investigator who was blinded to the results of the ECE. In random order, capsule endoscopy videos were read and interpreted by the study investigator blinded to EGD results. 28 patients (19 men, 9 women; mean age 53.3 years) were included. In 82 % of the patients, at least 75 % of the Z line was visualized by the PillCam ESO 2. A per-lesion analysis demonstrated that the PillCam ESO 2 had definitive results in 30/43 lesions (69.8 %) and EGD in 29/43 (67.4 %), P value = 0.41. Compared with EGD for detecting suspected Barrett's esophagus and esophagitis, the PillCam ESO 2 had a sensitivity of 100 % and a specificity of 74 %, and a sensitivity of 80 % and a specificity of 87 %, respectively. The PillCam ESO 2 demonstrated 86 % agreement with EGD in describing the Z line (kappa statistic 0.68). The modified ingestion protocol provided excellent cleansing, with bubbles/saliva having no or only a minor effect on Z line images in 86 % of cases. The PillCam ESO 2 demonstrated excellent visualization of the Z line. Compared with standard EGD, the PillCam ESO 2 had good test characteristics with high rates of detection of suspected Barrett's esophagus and esophagitis. This study provides indirect validation of the simplified ingestion procedure. The PillCam ESO 2 acquires high quality esophageal images, performs safely, and should be able to replace the current PillCam ESO.
Opponency of astringent and fat sensations.
des Gachons, Catherine Peyrot; Mura, Emi; Speziale, Camille; Favreau, Charlotte J; Dubreuil, Guillaume F; Breslin, Paul A S
2012-10-09
In most cultures, people ingest a variety of astringent foods and beverages during meals, but the reasons for this practice are unclear. Many popular beliefs and heuristics, such as high tannin wines should be balanced with fatty foods, for example 'red wine with red meat', suggest that astringents such as pickles, sorbets, wines, and teas 'cleanse' the palate while eating. Oral astringents elicit 'dry, rough' sensations [1], in part, by breaking down mucinous lubricating proteins in saliva [2,3]. The introduction of oral lubricants, including fats, partially diminishes strong astringent sensations [4,5]. Thus, it appears that astringency and fattiness can oppose each other perceptually on an oral rheological spectrum. Most teas, wines, and 'palate cleansers', however, are only mildly astringent and an explanation of how they could oppose the fattiness of meals is lacking. Here, we demonstrate that weakly astringent stimuli can elicit strong sensations after repeated sampling. Astringency builds with exposures [6] to an asymptotic level determined by the structure and concentration of the compound. We also establish that multiple sips of a mild astringent solution, similar to a wine or tea, decrease oral fat sensations elicited by fatty food consumption when astringent and fatty stimuli alternate, mimicking the patterning that occurs during a real meal. Consequently, we reveal a principle underlying the international practice of 'palate cleansing'. Repeatedly alternating samples of astringent beverages with fatty foods yielded ratings of fattiness and astringency that were lower than if rinsing with water or if presented alone without alternation. Copyright © 2012 Elsevier Ltd. All rights reserved.
Joshi, Saumitra V; Ghosh, Sat
2014-11-21
The detrimental impact of rising air pollution levels in urban landscapes has become conspicuous over the last decade, particularly in developing countries. This novel numerical study quantifies the cleansing efficiency of green façades draped with a copiously growing tropical creeper Vernonia elaeagnifolia. Turbulent transport of SO2 to the leaf boundary layer and subsequent diffusion across stomatal pores into the mesophyllic cells is modeled at the micro level, including its ionic dissociation in the leaf׳s interior. A SEM analysis indicates stomatal dimensions and density. Whilst previous studies have used either spatially averaged equations or resistance models, a spatially discretized computational approach is adopted in this study. The resulting concentration distribution is used to calculate the deposition velocity on stomatal pores, which is then extrapolated over the entire façade to yield bulk pollutant removal rates. A deposition velocity of 1.53mms(-1) and 0.72mms(-1) is obtained for open and closed pores respectively, with removal rates equal to 1.11×10(-6)s(-1) and 1.05×10(-6)s(-1) for dry and humid weather respectively. Sensitivity studies on the removal rate are carried out based on humidity, stomatal aperture and leaf temperature. The removal rate dependence on the Leaf Area Index (LAI) is also investigated. It is inferred from simulations that vegetated façades are efficient at mitigation of residual pollution. Copyright © 2014 Elsevier Ltd. All rights reserved.
Keedy, Alexander W.; Aslam, Rizwan; Weinstein, Stefanie; Landeras, Luis A.; Shah, Janak N.; McQuaid, Kenneth R.; Yeh, Benjamin M.
2011-01-01
Purpose: To prospectively compare adequacy of colonic cleansing, adequacy of solid stool and fluid tagging, and patient acceptance by using reduced-volume, 2-L polyethylene glycol (PEG) versus magnesium citrate bowel preparations for CT colonography. Materials and Methods: This study was approved by the institutional Committee on Human Research and was compliant with HIPAA; all patients provided written consent. In this randomized, investigator-blinded study, 50 patients underwent oral preparation with either a 2-L PEG or a magnesium citrate solution, tagging with oral contrast agents, and subsequent CT colonography and segmentally unblinded colonoscopy. The residual stool (score 0 [best] to 3 [worst]) and fluid (score 0 [best] to 4 [worst]) burden and tagging adequacy were qualitatively assessed. Residual fluid attenuation was recorded as a quantitative measure of tagging adequacy. Patients completed a tolerance questionnaire within 2 weeks of scanning. Preparations were compared for residual stool and fluid by using generalized estimating equations; the Mann-Whitney test was used to compare the qualitative tagging score, mean residual fluid attenuation, and adverse effects assessed on the patient experience questionnaire. Results: The mean residual stool (0.90 of three) and fluid burden (1.05 of four) scores for PEG were similar to those for magnesium citrate (0.96 [P = .58] and 0.98 [P = .48], respectively). However, the mean fecal and fluid tagging scores were significantly better for PEG (0.48 and 0.28, respectively) than for magnesium citrate (1.52 [P < .01] and 1.28 [P < .01], respectively). Mean residual fluid attenuation was higher for PEG (765 HU) than for magnesium citrate (443 HU, P = .01), and mean interpretation time was shorter for PEG (14.8 minutes) than for magnesium citrate (18.0 minutes, P = .04). Tolerance ratings were not significantly different between preparations. Conclusion: Reduced-volume PEG and magnesium citrate bowel preparations demonstrated adequate cleansing effectiveness for CT colonography, with better tagging and shorter interpretation time observed in the PEG group. Adequate polyp detection was maintained but requires further validation because of the small number of clinically important polyps. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11110217/-/DC1 PMID:21873253
Assessment of Hygiene Habits in Acrylic Denture Wearers: a Cross-sectional Study
Aoun, Georges; Gerges, Elie
2017-01-01
Objectives: To assess the denture hygiene habits in a population of Lebanese denture wearers. Materials and Methods: One hundred and thirty-two (132) patients [71 women (53.8%) and 61 men (46.2%)] wearing their acrylic dentures for more than two years were included in this study. The hygiene methods related to their dentures were evaluated and the data obtained were analyzed statistically using the IBM® SPSS® statistics 20.0 (USA) statistical package. Results: Regardless of the cleaning technique, the big majority of our participants [123 out of 132 (93.1%)] cleaned their dentures daily. The two mostly used denture cleaning techniques were rinsing with tap water (34.1%) and brushing with toothpaste (31.8%). Nearly half of our patients (45.5%) soaked their dentures during the night; most of them with cleansing tablets dissolved in water (28.8%). Conclusions: Within the limitations of our study, it was concluded that in a sample of Lebanese population surveyed about denture hygiene habits, the daily frequency of denture cleaning is satisfactory, but the techniques and products used were self-estimated and, consequently, not sufficient. PMID:29109670
EEMCO guidance for the efficacy assessment of antiperspirants and deodorants.
Piérard, G E; Elsner, P; Marks, R; Masson, P; Paye, M
2003-01-01
Overproduction of sweat, sweaty skin and body odours are unpleasant for many social groups. Body cleansing products are designed to combat these undesirable features of skin. In addition, antiperspirant and deodorant products are more specifically used in the underarm site by a large part of the adult population. Antiperspirants are offered to control emotionally triggered sweating in the armpit. Deodorants are designed to combat malodour generated from bacteria-modified sweat. This review summarizes the physiology of eccrine, apocrine and apoeccrine sweat glands. The mechanisms of action of antiperspirants and deodorants are described as well as the factors influencing their efficacies. A series of tests using various measurement methods can be used to demonstrate the efficacy of antiperspirants. These include the gravimetric method, water evaporation quantification, electrodermal measurements, staining procedures, dye injections and cyanoacrylate skin surface strippings and casting replicas. Deodorant efficacy can be evaluated by sensory assessments performed by an expert panel. Indirect support is provided by visualization of apocrine gland excretion and collection of sweat and volatile compounds. Microbiological assessments and chromatographic analysis also provide indirect information. Copyright 2003 S. Karger AG, Basel
Burgess, Robert M; Ryba, Stephan A; Cantwell, Mark G; Gundersen, Jennifer L; Tien, Rex; Perron, Monique M
2006-08-01
Coal fly ash has a very high sorption capacity for a variety of anthropogenic contaminants and has been used to cleanse wastewater of pollutants for approximately 40 years. Like other black carbons, the planar structure of the residual carbon in fly ash results in elevated affinities for planar organic contaminants, such as polycyclic aromatic hydrocarbons (PAHs) and some polychlorinated biphenyls (PCBs). The present study was performed to understand better the mechanisms affecting the strong interaction between planar contaminants and coal fly ash. The removal of 10 PCBs and 10 PAHs by several fly ashes and other sorbents was evaluated under different experimental conditions to highlight the intermolecular forces influencing adsorption. Varying fly ash concentration and solvent system composition indicated that dispersive interactions were most prevalent. For the PCBs, empirical results also were compared to molecular modeling estimates of the energy necessary for the PCB molecule to assume a planar conformation (PCe). The PCe levels ranged from 8 to 25 kcal/mol, depending on the degree of ortho-substituted chlorination of the PCB. A significant correlation between PCe and PCB removal from solution was observed for the fly ashes and activated carbon, whereas the nonplanar sorbent octadecyl (C18) indicated no relationship. These findings demonstrate the strong interaction between black carbon fly ash and planar organic contaminants. Furthermore, as exemplified by the PCBs, these results show how this interaction is a function of a contaminant's ability to assume a planar conformation.
2014-01-01
Background Reintegration programs are commonly offered to former combatants and abductees to acquire civilian status and support services to reintegrate into post-conflict society. Among a group of young female abductees in northern Uganda, this study examined access to post-abduction reintegration programming and tested for between group differences in mental health status among young women who had accessed reintegration programming compared to those who self-reintegrated. Methods This cross-sectional study analysed interviews from 129 young women who had previously been abducted by the Lords Resistance Army (LRA). Data was collected between June 2011-January 2012. Interviews collected information on abduction-related experiences including age and year of abduction, manner of departure, and reintegration status. Participants were coded as ‘reintegrated’ if they reported ≥1 of the following reintegration programs: traditional cleansing ceremony, received an amnesty certificate, reinsertion package, or had gone to a reception centre. A t-test was used to measure mean differences in depression and anxiety measured by the Acholi Psychosocial Assessment Instrument (APAI) to determine if abductees who participated in a reintegration program had different mental status from those who self-reintegrated. Results From 129 young abductees, 56 (43.4%) had participated in a reintegration program. Participants had been abducted between 1988–2010 for an average length of one year, the median age of abduction was 13 years (IQR:11–14) with escaping (76.6%), being released (15.6%), and rescued (7.0%) being the most common manner of departure from the LRA. Traditional cleansing ceremonies (67.8%) were the most commonly accessed support followed by receiving amnesty (37.5%), going to a reception centre (28.6%) or receiving a reinsertion package (12.5%). Between group comparisons indicated that the mental health status of abductees who accessed ≥1 reintegration program were not significantly different from those who self-reintegrated (p > 0.05). Conclusions Over 40% of female abductees in this sample had accessed a reintegration program, however significant differences in mental health were not observed between those who accessed a reintegration program and those who self-reintegrated. The successful reintegration of combatants and abductees into their recipient community is a complex process and these results support the need for gender-specific services and ongoing evaluation of reintegration programming. PMID:24855489
Poison ivy, oak, and sumac dermatitis identification, treatment, and prevention.
Garner, L A
1999-05-01
Allergic contact dermatitis from poison ivy, oak, or sumac is common among people who work or exercise outdoors. The plants, classified in the genus Rhus or Toxicodendron, contain allergens that can cause reactions ranging from mild pruritus to severe urticaria or generalized maculopapular eruptions. Initial management includes cleansing, cold compresses, and, possibly, oral antihistamines for symptomatic relief. Topical corticosteroids are given for localized nonfacial eruptions; systemic corticosteroids are used for severe eruptions. Prevention involves avoiding contact with the plants and washing exposed skin within 2 hours.
Causality implies inflationary back-reaction
NASA Astrophysics Data System (ADS)
Basu, S.; Tsamis, N. C.; Woodard, R. P.
2017-07-01
There is a widespread belief among inflationary cosmologists that a local observer cannot sense super-horizon gravitons. The argument goes that a local observer would subsume super-horizon gravitons into a redefinition of his coordinate system. We show that adopting this view for pure gravity on de Sitter background leads to time variation in the Hubble parameter measured by a local observer. It also leads to a violation of the gravitational field equation R = 4Λ because that equation is obeyed by the full metric, rather than the one which has been cleansed of super-horizon modes.